Kee, Changwon; Cho, Changhwan
2003-06-01
The authors investigated the correlation between visual field defects detected by automated perimetry and the thickness of the retinal nerve fiber layer measured with optical coherence tomography, and examined whether there is a decrease in retinal nerve fiber layer thickness in the apparently normal hemifield of glaucomatous eyes. Forty-one patients with glaucoma and 41 normal control subjects were included in this study. Statistical correlations between the sum of the total deviation of 37 stimuli of each hemifield and the ratio of decrease in retinal nerve fiber layer thickness were evaluated. The statistical difference between the retinal nerve fiber layer thickness of the apparently normal hemifield in glaucomatous eyes and that of the corresponding hemifield in normal subjects was also evaluated. There was a statistically significant correlation in the sum of the total deviation and retinal nerve fiber layer thickness decrease ratio (superior hemifield, P = 0.001; inferior hemifield, P = 0.003). There was no significant decrease in retinal nerve fiber layer thickness in the area that corresponded to the normal visual field in the hemifield defect with respect to the horizontal meridian in glaucomatous eyes (superior side, P = 0.148; inferior side, P = 0.341). Optical coherence tomography was capable of demonstrating and measuring retinal nerve fiber layer abnormalities. No changes in the retinal nerve fiber layer thickness of the apparently normal hemifield were observed in glaucomatous eyes.
Shulman, S; Shorer, R; Wollman, J; Dotan, G; Paran, D
2017-11-01
Background Cognitive impairment is frequent in systemic lupus erythematosus. Atrophy of the corpus callosum and hippocampus have been reported in patients with systemic lupus erythematosus, and diffusion tensor imaging studies have shown impaired white matter integrity, suggesting that white matter damage in systemic lupus erythematosus may underlie the cognitive impairment as well as other neuropsychiatric systemic lupus erythematosus manifestations. Retinal nerve fiber layer thickness, as assessed by optical coherence tomography, has been suggested as a biomarker for white matter damage in neurologic disorders such as multiple sclerosis, Alzheimer's disease and Parkinson's disease. Retinal nerve fiber layer thinning may occur early, even in patients with mild clinical symptoms. Aim The objective of this study was to assess the association of retinal nerve fiber layer thickness, as a biomarker of white matter damage in systemic lupus erythematosus patients, with neuropsychiatric systemic lupus erythematosus manifestations, including cognitive impairment. Methods Twenty-one consecutive patients with systemic lupus erythematosus underwent neuropsychological testing using a validated computerized battery of tests as well as the Rey-Auditory verbal learning test. All 21 patients, as well as 11 healthy, age matched controls, underwent optical coherence tomography testing to assess retinal nerve fiber layer thickness. Correlations between retinal nerve fiber layer thickness and results in eight cognitive domains assessed by the computerized battery of tests as well as the Rey-Auditory verbal learning test were assessed in patients with systemic lupus erythematosus, with and without neuropsychiatric systemic lupus erythematosus, and compared to retinal nerve fiber layer thickness in healthy controls. Results No statistically significant correlation was found between retinal nerve fiber layer thickness in patients with systemic lupus erythematosus as compared to healthy controls. When evaluating by subgroups, no correlation was found between patients with or without neuropsychiatric systemic lupus erythematosus or cognitive impairment and retinal nerve fiber layer thickness. Conclusion Retinal nerve fiber layer thickness of systemic lupus erythematosus patients was not found to be statistically different compared to controls. Within systemic lupus erythematosus patients there was no correlation between retinal nerve fiber layer thickness and cognitive impairment or other neuropsychiatric systemic lupus erythematosus manifestations.
Abdellatif, Mona K; Fouad, Mohamed M
2018-03-01
To investigate the factors in migraine that have the highest significance on retinal and choroidal layers' thickness. Ninety patients with migraine and 40 age-matched healthy participants were enrolled in this observational, cross-sectional study. After full ophthalmological examination, spectral domain-optical coherence tomography was done for all patients measuring the thickness of ganglion cell layer and retinal nerve fiber layer. Enhanced depth imaging technique was used to measure the choroidal thickness. There was significant thinning in the superior and inferior ganglion cell layers, all retinal nerve fiber layer quadrants, and all choroidal quadrants (except for the central subfield) in migraineurs compared to controls. The duration of migraine was significantly correlated with ganglion cell layer, retinal nerve fiber layer, and all choroidal quadrants, while the severity of migraine was significantly correlated with ganglion cell layer and retinal nerve fiber layer only. Multiregression analysis showed that the duration of migraine is the most important determinant factor of the superior retinal nerve fiber layer quadrant (β = -0.375, p = 0.001) and in all the choroidal quadrants (β = -0.531, -0.692, -0.503, -0.461, -0.564, respectively, p < 0.001), while severity is the most important determinant factor of inferior, nasal, and temporal retinal nerve fiber layer quadrants (β = -0.256, -0.335, -0.308; p = 0.036, 0.005, 0.009, respectively) and the inferior ganglion cell layer hemisphere (β = -0.377 and p = 0.001). Ganglion cell layer, retinal nerve fiber layer, and choroidal thickness are significantly thinner in patients with migraine. The severity of migraine has more significant influence in the thinning of ganglion cell layer and retinal nerve fiber layer, while the duration of the disease affected the choroidal thickness more.
Villain, Max A; Greenfield, David S
2003-01-01
To assess reproducibility of quadrantic and clock hour sectors of retinal nerve fiber layer thickness in normal eyes using optical coherence tomography. Normal eyes of healthy volunteers meeting eligibility criteria were imaged by two inexperienced operators. Six 360 degrees circular scans with a diameter of 3.4 mm centered on the optic disc were obtained during each scanning session, and a baseline image was formed using 3 high-quality images defined by the software. Images were obtained on three different days within a 4-week period. Variance and coefficient of variation (CV) were calculated for quadrantic and retinal nerve fiber layer clock hour sectors obtained from the baseline image. Five normal eyes were scanned. Intraoperator reproducibility was high. The mean (+/- SD) CV for total retinal nerve fiber layer thickness was 5.3 +/- 3.82% and 4.33 +/- 3.7% for operators 1 and 2, respectively. Interoperator reproducibility was good with statistically similar variance for all quadrantic and clock hour retinal nerve fiber layer parameters (P = .42 to .99). The nasal retinal nerve fiber layer was the most variable sector for both operators (mean CV: 10.42% and 7.83% for operators 1 and 2, respectively). Differences in mean total, nasal, temporal, and superior retinal nerve fiber layer thickness were not statistically significant between operators for all eyes; however, for inferior retinal nerve fiber layer thickness, there was a significant (P = .0007) difference between operators in one eye. Peripapillary retinal nerve fiber layer thickness assessments using optical coherence tomography have good intraoperator and interoperator reproducibility. Inexperienced operators can generate useful measurement data with acceptable levels of variance.
Retinal nerve fiber layer changes after LASIK evaluated with optical coherence tomography.
Dementyev, Dmitriy D; Kourenkov, Vyacheslav V; Rodin, Alexander S; Fadeykina, Tatyana L; Diaz Martines, Tatyana E
2005-01-01
To determine whether the increase in intraocular pressure (IOP) during LASIK suction can induce a decrease in retinal nerve fiber layer thickness assessed by optical coherence tomography (OCT). Nineteen patients (38 eyes) were enrolled in the study. Intraocular pressure was normal at all pre- and postoperative examinations. Retinal nerve fiber layer thickness was measured using OCT-3 Stratus prior to and 1 week and 3 months after LASIK. Laser in situ keratomileusis was performed using the Bausch & Lomb Hansatome microkeratome and the NIDEK EC-5000 excimer laser. Optical coherence tomography mean retinal nerve fiber layer thickness values before and after LASIK were compared using the Student paired t test. Mean patient age was 27.8 years (range: 18 to 33 years). Mean preoperative spherical equivalent refractive error was -4.9 diopters (D) (range: -2.0 to -8.5 D). Mean time of microkeratome suction was 30 seconds (range: 20 to 50 seconds). Preoperatively, the mean retinal nerve fiber layer thickness obtained by OCT was 104.2+/-9.0 microm; at 1 week postoperatively the mean thickness was 101.9+/-6.9 microm, and 106.7+/-6.1 microm at 3 months postoperatively. Mean retinal nerve fiber layer thicknesses obtained by OCT were not significantly different between preoperative and 1 week and 3 months after LASIK (P > or = .05). Laser in situ keratomileusis performed on young myopic patients does not have a significant effect on retinal nerve fiber layer thickness determined by OCT. Further studies are required to reveal the risk of possible optic nerve or retinal nerve fiber layer damage by elevated IOP during LASIK.
Cense, B; Chen, T C; de Boer, J F
2006-01-01
Thinning of the retinal nerve fiber layer and changes in retinal nerve fiber layer birefringence may both precede clinically detectable glaucomatous vision loss. We present in vivo thickness and depth-resolved birefringence measurements of the human retinal nerve fiber layer (RNFL) by use of polarization-sensitive optical coherence tomography (PS-OCT). Using a fiber-based PS-OCT setup real-time images of the human retina in vivo were recorded, co-registered with retinal video images of the location of PS-OCT scans. PS-OCT scans around the optic nerve head (ONH) of two healthy young volunteers were made using 10 concentric circles of increasing radius. Both the mean retinal nerve fiber layer thickness and mean retinal nerve fiber birefringence for each of 48 sectors on a circle were determined. The retinal nerve fiber layer thickness and birefringence varied as a function of sector around the ONH. Measured double pass phase retardation per unit depth values around the ONH range between 0.10 and 0.35 degrees/microm. The retinal nerve fiber layer becomes thinner with increasing distance from the ONH. In contrast, the birefringence does not vary significantly with increasing distance from the ONH.
Turan, Kadriye Erkan; Sekeroglu, Hande Taylan; Baytaroglu, Ata; Bezci, Figen; Karahan, Sevilay
2018-01-01
To (a) determine the normative values for optical coherence tomography (OCT) parameters such as central macular thickness, retinal nerve fiber layer thickness, and choroidal thickness in healthy children; (b) investigate the relationships of these parameters with axial length, central corneal thickness, refractive errors, and intraocular pressure; and (c) determine interexaminer agreement for choroidal thickness measurements. In this cross-sectional study, 120 healthy children aged 8-15 years underwent detailed ophthalmological examination and OCT measurements. Choroidal thickness was measured at three separate locations by two independent examiners. The mean global retinal nerve fiber layer thickness was 98.75 ± 9.45 μm (79.0-121.0). The mean central macular thickness was 232.29 ± 29.37 μm (190.0-376.0). The mean subfoveal choroidal thickness obtained by examiner 1 was 344.38 ± 68.83 μm and that obtained by examiner 2 was 344.04 ± 68.92 μm. Interexaminer agreement was between 99.6%-99.8% for choroidal thickness at three separate locations. Central macular thickness increased with axial length (r=0.245, p=0.007). Choroidal thickness increased with age (r=0.291, p=0.001) and decreased with axial length (r=-0.191, p=0.037). Global retinal nerve fiber layer thickness decreased with axial length (r=-0.247, p=0.007) and increased with central corneal thickness (r=0.208, p=0.022). Global retinal nerve fiber layer thickness positively correlated with choroidal thickness (r=0.354, p<0.001). Global retinal nerve fiber layer thickness (r=0.223, p=0.014) and choroidal thickness (r=0.272, p=0.003) increased with the spherical equivalent (D). Optical coherence tomography parameters showed a wide range of variability in children. Retinal nerve fiber layer thickness, central macular thickness, and choroidal thickness were found to be either inter-related or correlated with age, central corneal thickness, axial length, and refractive errors. Furthermore, manual measurements of choroidal thickness showed high interexaminer agreement. Because normative values for optical coherence tomography parameters differed in children, the measurements should be interpreted according to an age-appropriate database.
Huynh, Son C; Wang, Xiu Ying; Rochtchina, Elena; Mitchell, Paul
2006-09-01
To study the distribution of retinal nerve fiber layer (RNFL) thickness by ocular and demographic variables in a population-based study of young children. Population-based cross-sectional study. One thousand seven hundred sixty-five of 2238 (78.9%) eligible 6-year-old children participated in the Sydney Childhood Eye Study between 2003 and 2004. Mean age was 6.7 years (50.9% boys). Detailed examination included cycloplegic autorefraction and measurement of axial length. Retinal nerve fiber layer scans using an optical coherence tomographer were performed with a circular scan pattern of 3.4-mm diameter. Multivariate analyses were performed to examine the distribution of RNFL parameters with gender, ethnicity, axial length, and refraction. Peripapillary RNFL thickness and RNFL(estimated integral) (RNFL(EI)), which measures the total cross-sectional area of ganglion cell axons converging onto the optic nerve head. Peripapillary RNFL thickness and RNFL(EI) were normally distributed. The mean+/-standard deviation RNFL average thickness was 103.7+/-11.4 microm and RNFL(EI) was 1.05+/-0.12 mm2. Retinal nerve fiber layer thickness was least for the temporal quadrant (75.7+/-14.7 microm), followed by the nasal (81.7+/-19.6 microm), inferior (127.8+/-20.5 microm), and superior (129.5+/-20.6 microm) quadrants. Multivariate adjusted RNFL average thickness was marginally greater in boys than in girls (104.7 microm vs. 103.2 microm; P = 0.007) and in East Asian than in white children (107.7 microm vs. 102.7 microm; P<0.0001). The RNFL was thinner with greater axial length (P(trend)<0.0001) and less positive spherical equivalent refractions (P(trend) = 0.004). Retinal nerve fiber layer average thickness and RNFL(EI) followed a normal distribution. Retinal nerve fiber layer thickness varied marginally with gender, but differences were more marked between white and East Asian children. Retinal nerve fiber layer thinning was associated with increasing axial length and less positive refractions.
Indium oxide based fiber optic SPR sensor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shukla, Sarika; Sharma, Navneet K., E-mail: navneetk.sharma@jiit.ac.in
2016-05-06
Surface plasmon resonance based fiber optic sensor using indium oxide layer is presented and theoretically studied. It has been found that with increase in thickness of indium oxide layer beyond 170 nm, the sensitivity of SPR sensor decreases. 170 nm thick indium oxide layer based SPR sensor holds maximum sensitivity.
Nanoparticles based fiber optic SPR sensor
NASA Astrophysics Data System (ADS)
Shah, Kruti; Sharma, Navneet K.
2018-05-01
Localized surface plasmon resonance based fiber optic sensor using platinum nanoparticles is proposed and theoretically analyzed. Increase in thickness of nanoparticles layer increases the sensitivity of sensor. 50 nm thick platinum nanoparticles layer based sensor reveals highest sensitivity.
Sun, Chao; Zhang, Jie; Gao, Shanglin; Zhang, Nan; Zhang, Yijun; Zhuang, Jian; Liu, Ming; Zhang, Xiaohui; Ren, Wei; Wu, Hua; Ye, Zuo-Guang
2018-06-18
The interphase between fiber and matrix plays an essential role in the performance of composites. Therefore, the ability to design or modify the interphase is a key technology needed to manufacture stronger and smarter composite. Recently, depositing nano-materials onto the surface of the fiber has become a promising approach to optimize the interphase and composites. But, the modified composites have not reached the highest strength yet, because the determining parameters, such as thickness of the nano-layer, are hardly controlled by the mentioned methods in reported works. Here, we deposit conformal ZnO nano-layer with various thicknesses onto the surfaces of glass fibers via the atomic layer deposition (ALD) method and a tremendous enhancement of interfacial shear strength of composites is achieved. Importantly, a critical thickness of ZnO nano-layer is obtained for the first time, giving rise to a maximal relative enhancement in the interfacial strength, which is more than 200% of the control fiber. In addition, the single modified fiber exhibits a potential application as a flexible, transparent, in-situ UV detector in composites. And, we find the UV-sensitivity also shows a strong correlation with the thickness of ZnO. To reveal the dependence of UV-sensitivity on thickness, a depletion thickness is estimated by a proposed model which is an essential guide to design the detectors with higher sensitivity. Consequently, such precise tailoring of the interphase offers an advanced way to improve and to flexibly control various macroscopic properties of multifunctional composites of the next generation.
Kanamori, Akiyasu; Nakamura, Makoto; Matsui, Noriko; Nagai, Azusa; Nakanishi, Yoriko; Kusuhara, Sentaro; Yamada, Yuko; Negi, Akira
2004-12-01
To analyze retinal nerve fiber layer (RNFL) thickness in eyes with band atrophy by use of optical coherence tomography (OCT) and to evaluate the ability of OCT to detect this characteristic pattern of RNFL loss. Cross-sectional, retrospective study. Thirty-four eyes of 18 patients with bitemporal hemianopia caused by optic chiasm compression by chiasmal tumors were studied. All eyes were divided into 3 groups according to visual field loss grading after Goldmann perimetry. Retinal nerve fiber layer thickness measurements with OCT. Retinal nerve fiber layer thickness around the optic disc was measured by OCT (3.4-mm diameter circle). Calculation of the changes in OCT parameters, including the horizontal (nasal + temporal quadrant RNFL thickness) and vertical values (superior + inferior quadrant RNFL thickness) was based on data from 160 normal eyes. Comparison between the 3 visual field grading groups was done with the analysis of variance test. The receiver operating characteristic (ROC) curve for the horizontal and vertical value were calculated, and the areas under the curve (AUC) were compared. Retinal nerve fiber layer thickness in eyes with band atrophy decreased in all OCT parameters. The reduction rate in average and temporal RNFL thickness and horizontal value was correlated with visual field grading. The AUC of horizontal value was 0.970+/-0.011, which was significantly different from AUC of vertical value (0.903+/-0.022). The degree of RNFL thickness reduction correlated with that of visual field defects. Optical coherence tomography was able to identify the characteristic pattern of RNFL loss in these eyes.
Lamina propria of the human vocal fold: histomorphometric study of collagen fibers.
Prades, Jean-Michel; Dumollard, Jean Marc; Duband, Sébastien; Timoshenko, Andrei; Richard, Céline; Dubois, Marie Dominique; Martin, Christian; Peoc'h, Michel
2010-04-01
Since the seminal work of M. Hirano, which defined the three-layered lamina propria of the human vocal fold, there has been confusion in the labeling of each layer. Recent studies described the composition of fibers and interstitial molecules within the lamina propria leading to various biomechanical properties. However, collagen fibers appear as the most important structure component. We used an optical analysis and the picrosirius-polarization method to describe collagen fibers from six adult and two fetal human larynges fixed in formalin and frontally sectioned in the middle part of the vocal fold. The deep layer of the lamina propria is the most densely organized band of collagen fibers penetrating the superficial muscle bundles of the vocal muscle. The mean thickness of this layer is about 36% of the lamina propria and shows a network of strongly birefringent fibers (collagen type I and III). The superficial layer of the lamina propria is a narrow band of collagen fibers immediately below the basement membrane of the epithelium. The mean thickness of this layer is about 13% of the lamina propria and shows strong birefringent fibers. The intermediate layer is the less densely organized band between the deep and superficial layers. The mean thickness of this layer is about 51% of the lamina propria and shows clear, green weakly birefringent fibers characterized as collagen type III. The fetal lamina propria contains only a monolayer distribution of loose collagen fibers between the epithelium and the vocal muscle. These results help describe the distribution of collagen fibers within the lamina propria of the human vocal fold and have implications to understand the cover-body theory of voice production both in the adult and newborn.
Horn, Folkert K; Mardin, Christian Y; Laemmer, Robert; Baleanu, Delia; Juenemann, Anselm M; Kruse, Friedrich E; Tornow, Ralf P
2009-05-01
To study the correlation between local perimetric field defects and glaucoma-induced thickness reduction of the nerve layer measured in the peripapillary area with scanning laser polarimetry (SLP) and spectral domain optical coherence tomography (SOCT) and to compare the results with those of a theoretical model. The thickness of the retinal nerve fiber layer was determined in 32 sectors (11.25 degrees each) by using SLP with variable cornea compensation (GDxVCC; Laser Diagnostics, San Diego, CA) and the newly introduced high-resolution SOCT (Spectralis; Heidelberg Engineering, Heidelberg, Germany). Eighty-eight healthy subjects served as control subjects, to determine the thickness deviation in patients with glaucoma. The relationship between glaucomatous nerve fiber reduction and visual field losses was calculated in six nerve fiber bundle-related areas. Sixty-four patients at different stages of open-angle glaucoma and 26 patients with ocular hypertension underwent perimetry (Octopus G1; Haag-Streit, Köniz, Switzerland) and measurements with the two morphometric techniques. Sector-shaped analyses between local perimetric losses and reduction of the retinal nerve fiber layer thickness showed a significant association for corresponding areas except for the central visual field in SLP. Correlation coefficients were highest in the area of the nasal inferior visual field (SOCT, -0.81; SLP, -0.57). A linear model describes the association between structural and functional damage. Localized perimetric defects can be explained by reduced nerve fiber layer thickness. The data indicate that the present SOCT is useful for determining the functional-structural relationship in peripapillary areas and that association between perimetric defects and corresponding nerve fiber losses is stronger for SOCT than for the present SLP. (ClinicalTrials.gov number, NCT00494923.).
Dereci, Selim; Koca, Tuğba; Akçam, Mustafa; Türkyilmaz, Kemal
2015-07-01
We investigated the peripapillary retinal nerve fiber layer thickness with optical coherence tomography in epileptic children receiving valproic acid monotherapy. The study was conducted on children aged 8-16 years who were undergoing valproic acid monotherapy for epilepsy. The study group comprised a total of 40 children who met the inclusion criteria and 40 healthy age- and sex-matched children as a control group. Children with at least a 1-year history of epilepsy and taking 10-40 mg/kg/day treatment were included in the study. Peripapillary retinal nerve fiber layer thickness measurements were performed using Cirrus HD optical coherence tomography. All children and parents were informed about the study and informed consent was obtained from the parents of all the participants. The study group included 21 girls and 19 boys with a mean age of 10.6 ± 2.3 years. According to the results of optical coherence tomography measurements, the mean peripapillary retinal nerve fiber layer thickness was 91.6 ± 9.7 in the patient group and 95.5 ± 7.4 μm in the control group (P < 0.05). The superior peripapillary retinal nerve fiber layer thickness was 112.0 ± 13.2 in the patient group and 120.0 ± 14.7 μm in the control group (P < 0.02). According to the results of both measurements, the peripapillary retinal nerve fiber layer thickness was significantly lower in the patient group. Neither color vision loss nor visual field examination abnormality could be documented. According to the optical coherence tomography measurements, the average and superior peripapillary retinal nerve fiber layer thicknesses were thinner in patients with epilepsy who were receiving valproic acid monotherapy compared with healthy children. This situation can lead to undesirable results in terms of eye health. New studies are needed to investigate whether these findings are the result of epilepsy or can be attributed to valproic acid and whether there are adverse effects of valproic acid later in life. Copyright © 2015 Elsevier Inc. All rights reserved.
Zucchiatti, Ilaria; Cicinelli, Maria V; Parodi, Maurizio Battaglia; Pierro, Luisa; Gagliardi, Marco; Accardo, Agostino; Bandello, Francesco
2017-07-01
To analyze the changes in ganglion cell complex and peripapillary retinal nerve fiber layer thickness, in central macular thickness and choroidal thickness on spectral domain optical coherence tomography in patients with neovascular age-related macular degeneration treated with intravitreal ranibizumab injections. All consecutive patients with untreated neovascular age-related macular degeneration received loading phase of three monthly intravitreal ranibizumab, followed by retreatments on a pro re nata protocol for 12 months. changes in ganglion cell complex and retinal nerve fiber layer at the end of follow-up. Secondary outcome: changes in best-corrected visual acuity, central macular thickness, and choroidal thickness at the end of follow-up. Choroidal thickness was measured at 500 μm, 1000 μm, and 1,500 μm intervals nasally, temporally, superiorly, and inferiorly to the fovea, respectively, on horizontal and vertical line scans centered on the fovea. Twenty-four eyes were included. Ganglion cell complex and peripapillary retinal nerve fiber layer thickness did not show statistically significant changes through 12 months (55.6 ± 18.5 and 81.9 ± 9.9 μm at baseline, 52.7 ± 19.3 and 84.6 ± 15.5 μm at month 12, P > 0.05). Central macular thickness showed progressive decrease from baseline to month 12, with maximum reduction at month 3 (P < 0.001). Statistically significant reduction in choroidal thickness was registered in the nasal 500, 1000, and 1,500 μm from the fovea, corresponding to the papillomacular region (from 169.6 ± 45.3 to 153.9 ± 46.9, P < 0.001). Intravitreal ranibizumab injections did not affect retinal nerve fiber layer and ganglion cell complex thickness in 1-year follow-up. Choroidal thickness in papillomacular area and central macular thickness was significantly reduced at the end of treatment. Further studies, with larger sample, longer follow-up, and greater number of injections, are warranted.
Shin, Il-Hwan; Lee, Woo-Hyuk; Lee, Jong-Joo; Jo, Young-Joon; Kim, Jung-Yeul
2018-02-01
To determine the repeatability of measuring the thickness of the central macula, retinal nerve fiber layer, and ganglion cell-inner plexiform layer (GC-IPL) using spectral domain optical coherence tomography (Cirrus HD-OCT) in eyes with age-related macular degeneration. One hundred and thirty-four eyes were included. The measurement repeatability was assessed by an experienced examiner who performed two consecutive measurements using a 512 × 128 macular cube scan and a 200 × 200 optic disk cube scan. To assess changes in macular morphology in patients with age-related macular degeneration, the patients were divided into the following three groups according to the central macular thickness (CMT): A group, CMT < 200 μm; B group, 200 μm ≤ CMT < 300 μm; and C group, CMT > 300 μm. Measurement repeatability was assessed using test-retest variability, a coefficient of variation, and an intraclass correlation coefficient. The mean measurement repeatability for the central macular, retinal nerve fiber layer, and GC-IPL thickness was high in the B group. The mean measurement repeatability for both the central macula and retinal nerve fiber layer thickness was high in the A and C groups, but was lower for the GC-IPL thickness. The measurement repeatability for GC-IPL thickness was high in the B group, but low in the A group and in the C group. The automated measurement repeatability for GC-IPL thickness was significantly lower in patients with age-related macular degeneration with out of normal CMT range. The effect of changes in macular morphology should be considered when analyzing GC-IPL thicknesses in a variety of ocular diseases.
Bijelic-Donova, Jasmina; Garoushi, Sufyan; Lassila, Lippo V J; Vallittu, Pekka K
2015-02-01
An oxygen inhibition layer develops on surfaces exposed to air during polymerization of particulate filling composite. This study assessed the thickness of the oxygen inhibition layer of short-fiber-reinforced composite in comparison with conventional particulate filling composites. The effect of an oxygen inhibition layer on the shear bond strength of incrementally placed particulate filling composite layers was also evaluated. Four different restorative composites were selected: everX Posterior (a short-fiber-reinforced composite), Z250, SupremeXT, and Silorane. All composites were evaluated regarding the thickness of the oxygen inhibition layer and for shear bond strength. An equal amount of each composite was polymerized in air between two glass plates and the thickness of the oxygen inhibition layer was measured using a stereomicroscope. Cylindrical-shaped specimens were prepared for measurement of shear bond strength by placing incrementally two layers of the same composite material. Before applying the second composite layer, the first increment's bonding site was treated as follows: grinding with 1,000-grit silicon-carbide (SiC) abrasive paper, or treatment with ethanol or with water-spray. The inhibition depth was lowest (11.6 μm) for water-sprayed Silorane and greatest (22.9 μm) for the water-sprayed short-fiber-reinforced composite. The shear bond strength ranged from 5.8 MPa (ground Silorane) to 36.4 MPa (water-sprayed SupremeXT). The presence of an oxygen inhibition layer enhanced the interlayer shear bond strength of all investigated materials, but its absence resulted in cohesive and mixed failures only with the short-fiber-reinforced composite. Thus, more durable adhesion with short-fiber-reinforced composite is expected. © 2014 Eur J Oral Sci.
Anisotropic fibrous thermal insulator of relatively thick cross section and method for making same
Reynolds, Carl D.; Ardary, Zane L.
1979-01-01
The present invention is directed to an anisotropic thermal insulator formed of carbon-bonded organic or inorganic fibers and having a thickness or cross section greater than about 3 centimeters. Delaminations and deleterious internal stresses generated during binder curing and carbonizing operations employed in the fabrication of thick fibrous insulation of thicknesses greater than 3 centimeters are essentially obviated by the method of the present invention. A slurry of fibers, thermosetting resin binder and water is vacuum molded into the selected insulator configuration with the total thickness of the molded slurry being less than about 3 centimeters, the binder is thermoset to join the fibers together at their nexaes, and then the binder is carbonized to form the carbon bond. A second slurry of the fibers, binder and water is then applied over the carbonized body with the vacuum molding, binder thermosetting and carbonizing steps being repeated to form a layered insulator with the binder providing a carbon bond between the layers. The molding, thermosetting and carbonizing steps may be repeated with additional slurries until the thermal insulator is of the desired final thickness. An additional feature of the present invention is provided by incorporating opacifying materials in any of the desired layers so as to provide different insulating properties at various temperatures. Concentration and/or type of additive can be varied from layer-to-layer.
A polarization measurement method for the quantification of retardation in optic nerve fiber layer
NASA Astrophysics Data System (ADS)
Fukuma, Yasufumi; Okazaki, Yoshio; Shioiri, Takashi; Iida, Yukio; Kikuta, Hisao; Ohnuma, Kazuhiko
2008-02-01
The thickness measurement of the optic nerve fiber layer is one of the most important evaluations for carrying out glaucoma diagnosis. Because the optic nerve fiber layer has birefringence, the thickness can be measured by illuminating eye optics with circular polarized light and analyzing the elliptical rate of the detected polarized light reflected from the optic nerve fiber layer. In this method, the scattering light from the background and the retardation caused by the cornea disturbs the precise measurement. If the Stokes vector expressing the whole state of polarization can be detected, we can eliminate numerically the influence of the background scattering and of the retardation caused by the cornea. Because the retardation process of the eye optics can be represented by a numerical equation using the retardation matrix of each component and also the nonpolarized background scattering light, it can be calculated by using the Stokes vector. We applied a polarization analysis system that can detect the Stokes vector onto the fundus camera. The polarization analysis system is constructed with a CCD area image sensor, a linear polarizing plate, a micro phase plate array, and a circularly polarized light illumination unit. With this simply constructed system, we can calculate the retardation caused only by the optic nerve fiber layer and it can predict the thickness of the optic nerve fiber layer. We report the method and the results graphically showing the retardation of the optic nerve fiber layer without the retardation of the cornea.
Akçam, H T; Capraz, I Y; Aktas, Z; Batur Caglayan, H Z; Ozhan Oktar, S; Hasanreisoglu, M; Irkec, C
2014-01-01
Purpose To compare both retinal nerve fiber layer thickness and orbital color Doppler ultrasonography parameters in patients with multiple sclerosis (MS) versus healthy controls. Methods This is an observational case–control study. Forty eyes from MS patients and twenty eyes from healthy volunteers were examined. Eyes were classified into three groups as group 1, eyes from MS patients with previous optic neuritis (n=20); group 2, eyes from MS patients without previous optic neuritis (n=20); and group 3, eyes from healthy controls (n=20). Following complete ophthalmologic examination and retinal nerve fiber layer thickness measurement for each group, blood flow velocities of posterior ciliary arteries, central retinal artery, ophthalmic artery, and superior ophthalmic vein were measured. Pourcelot index (resistive index), an indicator of peripheral vascular resistance, was also calculated. The statistical assessment was performed with the assistance of Pearson's Chi-square test, Mann–Whitney U-test, Kruskal–Wallis test, and Spearman's correlation test. Results The studied eyes exposed similar values in terms of intraocular pressure and central corneal thickness, implying no evidence in favor of glaucoma. All nerve fiber layer thickness values, except superior nasal quadrants, in group 1 were found to be significantly thinner than groups 2 and 3. Blood flow velocity and mean resistivity index parameters were similar in all the groups. Conclusions In MS patients, especially with previous optic neuritis, diminished retinal nerve fiber layer thickness was observed. Contrary to several studies in the current literature, no evidence supporting potential vascular origin of ocular involvement in MS was found. PMID:25081285
Characterization of BN rich layer on ammonia treated Nextel{trademark}312 fibers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khasgiwale, N.R.; Butler, E.P.; Tsakalakos, L.
A BN rich layer grown on Nextel{trademark}312 fibers by appropriate ammonia treatments was evaluated using various complimentary techniques including X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), Scanning Electron Microscopy (SEM), and Transmission Electron Microscopy (TEM)/Parallel Electron Energy Loss Spectroscopy (PEELS in TEM). Three different ammonia treatments were studied. Ammonia treatment resulted in crystallization of the Nextel{trademark}312 fiber. The BN rich surface layer formed due to ammonia treatment was clearly detected in XPS and PEELS both before and after oxidation. The layer thickness was estimated to be between 5--10 nm. The layer was stable after oxidation treatment at 600 C formore » 100 hours. High resolution TEM observations of the fiber surface revealed a variable BN rich layer thickness. Patches of turbostratic BN were observed under certain conditions, however mostly the layer appeared to be amorphous.« less
Khalf, Abdurizzagh; Madihally, Sundararajan V
2017-07-01
Recent advances in electrospinning allow the formation of multiple layers of micro and nanosize fibers to regulate drug/therapeutic agent release. Although there has been significant progress in fiber formation techniques and drug loading, fundamental models providing insights into controlling individual permeabilities is lacking. In this regard, we first explored forming coaxial hybrid fibers from hydrophobic poly(ε-caprolactone) (PCL) and hydrophilic gelatin (GT) in three different configurations, and the release of hydrophilic doxycycline (Dox) at 37°C over five days. Triaxial fibers were also formed with a GT layer between PCL/GT layers. Fibers were analyzed for fiber thickness, matrix porosity and thickness, surface morphologies, internal structures, stability in hydrated condition, viability and attachment of human adipocyte stem cells (hASC). Formed fibers were 10-30μm in diameter. hASC were viable, and showed attachment. Various release profiles were obtained from these fibers based on the combination of the core and shell polymers over five days. Using fiber characteristics and release profiles from each configuration, we obtained the overall permeability using Fick's first law and then individual layer permeability using resistance in series model. Calculated overall permeability showed dependency on fiber thickness and partition coefficient of the drug in the region where it was loaded. Our modeling approach helps in optimizing the electrospinning process, drug loading, and polymer solution configuration in regulating controlled release of a drug. Copyright © 2017 Elsevier B.V. All rights reserved.
Intestinal Mechanomorphological Remodeling Induced by Long-Term Low-Fiber Diet in Rabbits.
Liu, Yue; Zhao, Jingbo; Liao, Donghua; Wang, Guixue; Gregersen, Hans
2017-12-01
Short-term feeding with low-fiber diet remodels the mechanomorphological properties in the rabbit small intestine. The aims were to study the effect of feeding low-fiber diet for 5 months on mechanomorphological properties including the collagen fraction in the rabbit intestines. Fifteen rabbits were divided into an Intervention group (IG, n = 10) fed a low-fiber diet and a Control group (CG, n = 5) fed a normal diet for 5 months. Five months later, four 10-cm-long segments obtained from the duodenum, jejunum, ileum and large intestine were used for histological and mechanical analysis, respectively. The wall thickness, wall area, mucosa and muscle layer thickness decreased whereas the submucosa layer thickness increased in the IG (p < 0.05). The collagen fraction decreased in all layers and segments in the IG (p < 0.05). The opening angle increased in the large intestine and decreased in the ileum in the IG (p < 0.05). The intestinal stress-strain curves for IG shifted to the right, indicating softening. The creep did not change in the four segments. The wall stiffness was associated with wall thickness and collagen fraction in the submucosa layer. Long-term low-fiber diet in rabbits induced histomorphometric and biomechanical remodelling of the intestines.
The light transmission and distribution in an optical fiber coated with TiO2 particles.
Wang, Wen; Ku, Young
2003-03-01
The light delivery and distribution phenomena along the optical fiber coated with the P-25 TiO(2) particles by dipping was investigated. The surface properties (coverage, roughness and thickness) of the TiO(2) layer coated on the optical fiber were characterized by SEM micrographs. For TiO(2) layer prepared from solutions containing less than 20 wt.% of TiO(2) slurry, the thickness of layer was increased linearly with the TiO(2) slurry content in solutions. The UV light intensity transmitted along a TiO(2)-coated optical fiber decreased more rapidly than that transmitted along a non-coated fiber. Based on the experimental results, the light intensity distribution around a coated optical fiber was modeled to determine the optimum configuration for the design of optical fiber reactors under various operational conditions. Copyright 2002 Elsevier Science Ltd.
Survey of Nerve Fiber Layer Thickness in Anisometropic and Strabismic Amblyopia.
Soltani Moghaddam, Reza; Medghalchi, Abdolreza; Alizadeh, Yousef
2017-01-01
. To investigate the effect of anisometropic and strabismic amblyopia on the nerve fiber layer thickness. This cross-sectional study was done on 54 amblyopic subjects, equally in both strabismic and anisometropic groups. The thickness otonerve fiber layer measured in superior, inferior, nasal, temporal quadrants and as a whole in both eyes of both groups. The means of thickness were compared in amblyopic and sound eyes. In strabismus group, the average nerve fiber layer thickness of the sound eye , in superior, inferior, nasal and temporal quadrants and as a whole were 113.23±14, 117.37±25, 68.96±6, 69.55±14 and 93.40±8 microns respectively. In amblyopic eyes of the same group, these measurements were 103.11±18, 67.74±11, and 69.59±16 and 89.59±12 microns in superior, inferior, nasal, temporal quadrants and as whole respectively. In anisometropic groups, the sound eye measurements were as 130.96±22, 129.07±29, 80.62±12, and 83.88±20 and 107.7±13 microns in superior, inferior, nasal and temporal quadrants and as a whole orderly. In amblyopic eyes of this group the mean thicknesses were 115.63±29, 133.15±25, 78.8±15, 80.2±16 and 109.17±21 microns in superior, inferior, nasal, temporal quadrants and as a whole respectively. Statistically, there were no significant differences between amblyopic and sound eyes (P>0.5). Our study did not support any significant change in a nerve fiber layer thickness of amblyopic patients; however, decreased thickness in superior and nasal quadrants of strabismic amblyopia and except inferior quadrant and as a whole. These measurements may be a clue for management and prognosis of amblyopia in old age.
García-Bella, Javier; Martínez de la Casa, José M; Talavero González, Paula; Fernández-Vigo, José I; Valcarce Rial, Laura; García-Feijóo, Julián
2018-01-01
To establish the changes produced after implantation of a trifocal intraocular lens (IOL) on retinal nerve fiber layer measurements performed with Fourier-domain optical coherence tomography (OCT). This prospective study included 100 eyes of 50 patients with bilateral cataract in surgical range, no other associated ocular involvement, refractive errors between +5 and -5 spherical diopters, and less than 1.5 D of corneal astigmatism. The eyes were operated by phacoemulsification with implantation of 2 different trifocal IOLs (FineVision and AT LISA tri 839MP) in randomized equal groups. Cirrus OCT and Spectralis OCT were performed before surgery and 3 months later. Both analyzed the thickness of the nerve fiber layer and thickness divided by quadrants (6 in case of Spectralis and 4 in case of Cirrus HD). The mean age of patients was 67.5 ± 5.8 years. The global nerve fiber layer thickness measured with Spectralis OCT was 96.77 μm before surgery and 99.55 μm after. With Cirrus OCT, the global thickness was 85.29 μm before surgery and 89.77 μm after. Statistically significant differences in global thickness measurements between preimplantation and postimplantation of the IOL were found with both OCT in the 2 groups. Statistically significant differences were also found in temporal and superior quadrants. The implantation of a diffractive trifocal IOL alters the results of the optic nerve fiber layer on Fourier-domain OCT in these patients, which should be taken into account in the posterior study of these patients.
Reduction in Retinal Nerve Fiber Layer Thickness in Young Adults with Autism Spectrum Disorders
ERIC Educational Resources Information Center
Emberti Gialloreti, Leonardo; Pardini, Matteo; Benassi, Francesca; Marciano, Sara; Amore, Mario; Mutolo, Maria Giulia; Porfirio, Maria Cristina; Curatolo, Paolo
2014-01-01
Recent years have seen an increase in the use of retinal nerve fiber layer (RNFL) evaluation as an easy-to-use, reproducible, proxy-measure of brain structural abnormalities. Here, we evaluated RNFL thickness in a group of subjects with high functioning autism (HFA) or with Asperger Syndrome (AS) to its potential as a tool to study autism…
El Beltagi, Tarek A; Bowd, Christopher; Boden, Catherine; Amini, Payam; Sample, Pamela A; Zangwill, Linda M; Weinreb, Robert N
2003-11-01
To determine the relationship between areas of glaucomatous retinal nerve fiber layer thinning identified by optical coherence tomography and areas of decreased visual field sensitivity identified by standard automated perimetry in glaucomatous eyes. Retrospective observational case series. Forty-three patients with glaucomatous optic neuropathy identified by optic disc stereo photographs and standard automated perimetry mean deviations >-8 dB were included. Participants were imaged with optical coherence tomography within 6 months of reliable standard automated perimetry testing. The location and number of optical coherence tomography clock hour retinal nerve fiber layer thickness measures outside normal limits were compared with the location and number of standard automated perimetry visual field zones outside normal limits. Further, the relationship between the deviation from normal optical coherence tomography-measured retinal nerve fiber layer thickness at each clock hour and the average pattern deviation in each visual field zone was examined by using linear regression (R(2)). The retinal nerve fiber layer areas most frequently outside normal limits were the inferior and inferior temporal regions. The least sensitive visual field zones were in the superior hemifield. Linear regression results (R(2)) showed that deviation from the normal retinal nerve fiber layer thickness at optical coherence tomography clock hour positions 6 o'clock, 7 o'clock, and 8 o'clock (inferior and inferior temporal) was best correlated with standard automated perimetry pattern deviation in visual field zones corresponding to the superior arcuate and nasal step regions (R(2) range, 0.34-0.57). These associations were much stronger than those between clock hour position 6 o'clock and the visual field zone corresponding to the inferior nasal step region (R(2) = 0.01). Localized retinal nerve fiber layer thinning, measured by optical coherence tomography, is topographically related to decreased localized standard automated perimetry sensitivity in glaucoma patients.
Garcia-Martin, Elena; Pinilla, Isabel; Sancho, Eva; Almarcegui, Carmen; Dolz, Isabel; Rodriguez-Mena, Diego; Fuertes, Isabel; Cuenca, Nicolas
2012-09-01
To evaluate the ability of time-domain and Fourier-domain optical coherence tomographies (OCTs) to detect macular and retinal nerve fiber layer atrophies in retinitis pigmentosa (RP). To test the intrasession reproducibility using three OCT instruments (Stratus, Cirrus, and Spectralis). Eighty eyes of 80 subjects (40 RP patients and 40 healthy subjects) underwent a visual field examination, together with 3 macular scans and 3 optic disk evaluations by the same experienced examiner using 3 OCT instruments. Differences between healthy and RP eyes were compared. The relationship between measurements with each OCT instrument was evaluated. Repeatability was studied by intraclass correlation coefficients and coefficients of variation. Macular and retinal nerve fiber layer atrophies were detected in RP patients for all OCT parameters. Macular and retinal nerve fiber layer thicknesses, as determined by the different OCTs, were correlated but significantly different (P < 0.05). Reproducibility was moderately high using Stratus, good using Cirrus and Spectralis, and excellent using the Tru-track technology of Spectralis. In RP eyes, measurements showed higher variability compared with healthy eyes. Differences in thickness measurements existed between OCT instruments, despite there being a high degree of correlation. Fourier-domain OCT can be considered a valid and repeatability technique to detect retinal nerve fiber layer atrophy in RP patients.
Scanning laser polarimetry retinal nerve fiber layer thickness measurements after LASIK.
Zangwill, Linda M; Abunto, Teresa; Bowd, Christopher; Angeles, Raymund; Schanzlin, David J; Weinreb, Robert N
2005-02-01
To compare retinal nerve fiber layer (RNFL) thickness measurements before and after LASIK. Cohort study. Twenty participants undergoing LASIK and 14 normal controls. Retinal nerve fiber layer thickness was measured before LASIK and approximately 3 months after surgery in one eye each of 20 patients using a scanning laser polarimeter (GDx Nerve Fiber Analyzer) with fixed corneal compensation (FCC), one with variable corneal compensation (GDx VCC), and optical coherence tomography (OCT). Fourteen normal controls also were tested at baseline and approximately 3 months later. Retinal nerve fiber layer thicknesses measured with the GDx FCC, GDx VCC, and OCT. At baseline, mean (95% confidence interval [CI]) RNFL thicknesses for the GDx FCC, GDx VCC, and OCT were 78.1 microm (72.2-83.9), 54.3 microm (52.7-56.0), and 96.8 microm (93.2-100.5), respectively. In both LASIK and control groups, there were no significant changes between baseline and follow-up examinations in GDx VCC and OCT RNFL thickness measurements globally or in the superior and inferior quadrants (mean change, <5 microm for each instrument). In the control group, there also was no significant change in GDx FCC measurements between baseline and follow-up. In LASIK patients, significant reductions were observed in GDx FCC RNFL measurements. Average absolute values of the mean (95% CI) change in thickness were 12.4 microm (7.7-17.2), 15.3 microm (9.6-20.9), and 12.9 microm (7.6-18.1) for GDx FCC RNFL measurements superiorly, inferiorly, and globally, respectively (all Ps < or = 0.001). LASIK does not seem to change RNFL thickness. Reduction in GDx FCC RNFL thickness measurements after LASIK is a measurement artifact and is most likely due to erroneous compensation for corneal birefringence. With scanning laser polarimetry, it is mandatory to compensate individually for change in corneal birefringence after LASIK to ensure accurate RNFL assessment.
Iyigundogdu, Ilkin; Derle, Eda; Asena, Leyla; Kural, Feride; Kibaroglu, Seda; Ocal, Ruhsen; Akkoyun, Imren; Can, Ufuk
2018-02-01
Aim To compare the relationship between white matter hyperintensities (WMH) on brain magnetic resonance imaging and retinal nerve fiber layer (RNFL), choroid, and ganglion cell layer (GCL) thicknesses in migraine patients and healthy subjects. We also assessed the role of cerebral hypoperfusion in the formation of these WMH lesions. Methods We enrolled 35 migraine patients without WMH, 37 migraine patients with WMH, and 37 healthy control subjects examined in the Neurology outpatient clinic of our tertiary center from May to December 2015. RFNL, choroid, and GCL thicknesses were measured by optic coherence tomography. Results There were no differences in the RFNL, choroid, or GCL thicknesses between migraine patients with and without WMH ( p > 0.05). Choroid layer thicknesses were significantly lower in migraine patients compared to control subjects ( p < 0.05), while there were no differences in RFNL and GCL thicknesses ( p > 0.05). Conclusions The 'only cerebral hypoperfusion' theory was insufficient to explain the pathophysiology of WMH lesions in migraine patients. In addition, the thinning of the choroid thicknesses in migraine patients suggests a potential causative role for cerebral hypoperfusion and decreased perfusion pressure of the choroid layer.
The low coherence Fabry-Pérot interferometer with diamond and ZnO layers
NASA Astrophysics Data System (ADS)
Majchrowicz, D.; Den, W.; Hirsch, M.
2016-09-01
The authors present a fiber-optic Fabry-Pérot interferometer built with the application of diamond and zinc oxide (ZnO) thin layers. Thin ZnO films were deposited on the tip of a standard telecommunication single-mode optical fiber (SMF- 28) while the diamond layer was grown on the plate of silicon substrate. Investigated ZnO layers were fabricated by atomic layer deposition (ALD) and the diamond films were deposited using Microwave Plasma Enhanced Chemical Vapor Deposition (μPE CVD) system. Different thickness of layers was examined. The measurements were performed for the fiber-optic Fabry-Pérot interferometer working in the reflective mode. Spectra were registered for various thicknesses of ZnO layer and various length of the air cavity. As a light source, two superluminescent diodes (SLD) with central wavelength of 1300 nm and 1550 nm were used in measurement set-up.
Morphological changes in diseased cementum layers: a scanning electron microscopy study.
Bilgin, E; Gürgan, C A; Arpak, M Nejat; Bostanci, H S; Güven, K
2004-05-01
The aim of this study was to compare the morphological changes that occurred in root cementum layers due to periodontal disease by using scanning electron microscopy (SEM). Ninety-two periodontally hopeless teeth extracted from 29 patients were studied. Measurements of probing depth (PD) and clinical attachment loss (CAL) were taken prior to extractions. After the longitudinal fracturing process of root specimens, healthy and diseased cementum layers of roots were evaluated by SEM for the thickness of the cementum and the morphological changes in collagen fibers. The result of SEM evaluation revealed a significant ( P < 0.001) decrease in the thickness of cementum layer on the diseased root surfaces compared to the healthy surfaces. There were denser and conspicuous collagen fibers with their interfibrillar matrix in cementum layers on the healthy root surfaces compared to the diseased surfaces. Within the limits of this study, the thickness of cementum layers in diseased areas was found to be significantly less than that in the healthy areas of root surfaces. However, there exist variations in the density and visibility of cemental fibers between individuals and within the individual.
Evaluation of Retinal Changes in Progressive Supranuclear Palsy and Parkinson Disease.
Gulmez Sevim, Duygu; Unlu, Metin; Gultekin, Murat; Karaca, Cagatay; Mirza, Meral; Mirza, Galip Ertugrul
2018-06-01
Differentiating Parkinson disease (PD) from progressive supranuclear palsy (PSP) can be challenging early in the clinical course. The aim of our study was to see if specific retinal changes could serve as a distinguishing feature. We used spectral domain optical coherence tomography (SD-OCT) with automatic segmentation to measure peripapillary nerve fiber layer thickness and the thickness and volume of retinal layers at the macula. Thicknesses of superior peripapillary retinal nerve fiber layer (pRNFL), macular ganglion cell layer, inner plexiform layer, inner nuclear layer, and macular volume were more affected in PSP compared with PD (P < 0.05). Thicker inferotemporal pRNFL and lower macular volume were detected in levodopa users compared with nonusers in patients with PD. PD and PSP are associated with distinct changes in retinal morphology, which can be assessed with SD-OCT.
Mallik, Arun Kumar; Farrell, Gerald; Wu, Qiang; Semenova, Yuliya
2017-05-10
In this paper, we investigate both theoretically and experimentally the influence of the agarose hydrogel layer thickness on the sensitivity of a proposed relative humidity (RH) sensor based on a silica microsphere resonator coated with agarose hydrogel. The operating principle of the sensor relies on excitation of whispering gallery modes (WGMs) in the coated silica microsphere using the evanescent field of a tapered fiber. A change in the ambient relative humidity is detected by measuring the wavelength shift of the WGMs in the transmission spectrum of the tapered fiber. Using perturbation theory, we analyze the influence of the agarose coating thickness on the sensitivity of the proposed sensor and compare the results of this analysis with experimental findings for different coating layer thicknesses. We demonstrate that an increase in the coating layer thickness initially leads to an increase in the sensitivity to RH and reaches saturation at higher values of the agarose layer thickness. The results of the study are useful for the design and optimization of microsphere sensor parameters to meet a performance specification.
Shin, Ji Soo
2017-01-01
Purpose The aim of this study was to evaluate the changes in thickness of each macular retinal layer, the peripapillary retinal nerve fiber layer (RNFL), and central macular thickness (CMT) after 577-nm pattern scanning laser (PASCAL) photocoagulation in patients with diabetic retinopathy. Methods This retrospective study included 33 eyes with diabetic retinopathy that underwent 577-nm PASCAL photocoagulation. Each retinal layer thickness, peripapillary RNFL thickness, and CMT were measured by spectral-domain optical coherence tomography before 577-nm PASCAL photocoagulation, as well as at 1, 6, and 12 months after 577-nm PASCAL photocoagulation. Computerized intraretinal segmentation of optical coherence tomography was performed to identify the thickness of each retinal layer. Results The average thickness of the RNFL, ganglion cell layer, inner plexiform layer, inner nuclear layer, inner retinal layer, and CMT at each follow-up increased significantly from baseline (p < 0.001), whereas that of the retinal pigment epithelium at each follow-up decreased significantly from baseline (p < 0.001). The average thickness of the peripapillary RNFL increased significantly at one month (p < 0.001). This thickness subsequently recovered to 7.48 µm, and there were no significant changes at six or 12 months compared to baseline (p > 0.05). Conclusions Each macular retinal layer and CMT had a tendency to increase for one year after 577-nm PASCAL photocoagulation, whereas the average thickness of retinal pigment epithelium decreased at one-year follow-up compared to the baseline. Although an increase in peripapillary RNFL thickness was observed one month after 577-nm PASCAL photocoagulation, there were no significant changes at the one-year follow-up compared to the baseline. PMID:29022292
Shin, Ji Soo; Lee, Young Hoon
2017-12-01
The aim of this study was to evaluate the changes in thickness of each macular retinal layer, the peripapillary retinal nerve fiber layer (RNFL), and central macular thickness (CMT) after 577-nm pattern scanning laser (PASCAL) photocoagulation in patients with diabetic retinopathy. This retrospective study included 33 eyes with diabetic retinopathy that underwent 577-nm PASCAL photocoagulation. Each retinal layer thickness, peripapillary RNFL thickness, and CMT were measured by spectral-domain optical coherence tomography before 577-nm PASCAL photocoagulation, as well as at 1, 6, and 12 months after 577-nm PASCAL photocoagulation. Computerized intraretinal segmentation of optical coherence tomography was performed to identify the thickness of each retinal layer. The average thickness of the RNFL, ganglion cell layer, inner plexiform layer, inner nuclear layer, inner retinal layer, and CMT at each follow-up increased significantly from baseline (p < 0.001), whereas that of the retinal pigment epithelium at each follow-up decreased significantly from baseline (p < 0.001). The average thickness of the peripapillary RNFL increased significantly at one month (p < 0.001). This thickness subsequently recovered to 7.48 μm, and there were no significant changes at six or 12 months compared to baseline (p > 0.05). Each macular retinal layer and CMT had a tendency to increase for one year after 577-nm PASCAL photocoagulation, whereas the average thickness of retinal pigment epithelium decreased at one-year follow-up compared to the baseline. Although an increase in peripapillary RNFL thickness was observed one month after 577-nm PASCAL photocoagulation, there were no significant changes at the one-year follow-up compared to the baseline. © 2017 The Korean Ophthalmological Society
Microcracking of Materials for Space
NASA Technical Reports Server (NTRS)
Brown, Timothy L.
1998-01-01
The effect of thermal-cycling-induced microcracking in fiber-reinforced polymer matrix composites is studied. Specific attention is focused on microcrack density as a function of the number of thermal cycles, and the effect of microcracking on the dimensional stability of composite materials. Changes in laminate coefficient of thermal expansion (CTE) and laminate stiffness are of primary concern. Included in the study are materials containing four different Thornel fiber types: a PAN-based T50 fiber and three pitch-based fibers, P55, P75, and P120. The fiber stiffnesses range from 55 Msi to 120 Msi. The fiber CTE's range from -0.50 x 1O(exp -6)/degrees F to -0.80 x 10(exp -6)/degrees F. Also included are three matrix types: Fiberite's 934 epoxy, Amoco's ERL1962 toughened epoxy, and YLA's RS3 cyanate ester. The lamination sequences of the materials considered include a cross-ply configuration, [0/90](sub 2s), and two quasi-isotropic configurations, [0/+45/-45/90](sub s), and [0/+45/90/-45](sub s). The layer thickness of the materials range from a nominal 0.001 in. to 0.005 in. In addition to the variety of materials considered, three different thermal cycling temperature ranges are considered. These temperature ranges are +/-250 degrees F, +/-l5O degrees F, and +/-50 degrees F. The combination of these material and geometric parameters and temperature ranges, combined with thermal cycling to thousands of cycles, makes this one of the most comprehensive studies of thermal-cycling-induced microcracking to date. Experimental comparisons are presented by examining the effect of layer thickness, fiber type, matrix type, and thermal cycling temperature range on microcracking and its influence on the laminates. Results regarding layer thickness effects indicate that thin-layer laminates microcrack more severely than identical laminates with thick layers. For some specimens in this study, the number of microcracks in thin-layer specimens exceeds that in thick-layer specimens by more than a factor of two. Despite the higher number of microcracks in the thin-layer specimens, small changes in CTE after thousands of cycles indicate that the thin-layer specimens are relatively unaffected by the presence of these cracks compared to the thick-layer specimens. Results regarding fiber type indicate that the number of microcracks and the change in CTE after thousands of cycles in the specimens containing PAN-based fibers are less than in the specimens containing comparable stiffness pitch-based fibers. Results for specimens containing the different pitch-based fibers indicate that after thousands of cycles, the number of microcracks in the specimens does not depend on the modulus or CTE of the fiber. The change in laminate CTE does, however, depend highly on the stiffness and CTE of the fiber. Fibers with higher stiffness and more negative CTE exhibit the lowest change in laminate CTE as a result of thermal cycling. The overall CTE of these specimens is, however, more negative as a result of the more negative CTE of the fiber. Results regarding matrix type based on the +/-250 degree F temperature range indicate that the RS3 cyanate ester resin system exhibits the greatest resistance to microcracking and the least change in CTE, particularly for cycles numbering 3000 and less. Extrapolations to higher numbers of cycles indicate, however, that the margin of increased performance is expected to decrease with additional thermal cycling. Results regarding thermal cycling temperature range depend on the matrix type considered and the layer thickness of the specimens. For the ERL1962 resin system, microcrack saturation is expected to occur in all specimens, regardless of the temperature range to which the specimens are exposed. By contrast, the RS3 resin system demonstrates a threshold effect such that cycled to less severe temperature ranges, microcracking does not occur. For the RS3 specimens with 0.005 in. layer thickness, no microcracking or changes in CTE are observed in specimens cycled between +/-150 degree F or +/- 50 degree F. For the RS3 specimens with 0.002 in. layer thickness, no microcracking or changes in CTE are observed in specimens cycled between +/-50 degree F. Results regarding laminate stiffness indicate negligible change in laminate stiffness due to thermal cycling for the materials and geometries considered in this investigation. The study includes X-ray examination of the specimens, showing that cracks observed at the edge of the specimens penetrate the entire width of the specimen. Glass transition temperatures of the specimens are measured, showing that resin chemistry is not altered as a result of thermal cycling. Results are also presented based on a one-dimensional shear lag analysis developed in the literature. The analysis requires material property information that is difficult to obtain experimentally. Using limited data from the present investigation, material properties associated with the analysis are modified to obtain reasonable agreement with measured microcrack densities. Based on these derived material properties, the analysis generally overpredicts the change in laminate CTE. Predicted changes in laminate stiffness show reasonable correlation with experimentally measured values.
Theoretical investigation on multilayer nanocomposite-based fiber optic SPR sensor
NASA Astrophysics Data System (ADS)
Shojaie, Ehsan; Madanipour, Khosro; Gharibzadeh, Azadeh; Abbasi, Shabnam
2017-06-01
In this work, a multilayer nanocomposite based fiber optic SPR sensor is considered and especially designed for CO2 gas detection. This proposed fiber sensor consists of fiber core, gold-silver alloy and the absorber layers. The investigation is based on the evaluation of the transmitted-power derived under the transfer matrix method and the multiple-reflection in the sensing area. In terms of sensitivity, the sensor performance is studied theoretically under various conditions related to the metal layer and its gold and silver nanoparticles to form a single alloy film. Effect of additional parameters such as the ratio of the alloy composition and the thickness of the alloy film on the performance of the SPR sensor is studied, as well. Finally, a four-layer structure is introduced to detect carbon dioxide gas. It contains core fiber, gold-silver alloy layer, an absorbent layer of carbon dioxide gas (KOH) and measurement environment. Lower price and size are the main advantages of using such a sensor in compare with commercial (NDIR) gas sensor. Theoretical results show by increasing the metal layer thickness the sensitivity of sensor is increased, and by increasing the ratio of the gold in alloy the sensitivity is decreased.
Angiographic and structural imaging using high axial resolution fiber-based visible-light OCT
Pi, Shaohua; Camino, Acner; Zhang, Miao; Cepurna, William; Liu, Gangjun; Huang, David; Morrison, John; Jia, Yali
2017-01-01
Optical coherence tomography using visible-light sources can increase the axial resolution without the need for broader spectral bandwidth. Here, a high-resolution, fiber-based, visible-light optical coherence tomography system is built and used to image normal retina in rats and blood vessels in chicken embryo. In the rat retina, accurate segmentation of retinal layer boundaries and quantification of layer thicknesses are accomplished. Furthermore, three distinct capillary plexuses in the retina and the choriocapillaris are identified and the characteristic pattern of the nerve fiber layer thickness in rats is revealed. In the chicken embryo model, the microvascular network and a venous bifurcation are examined and the ability to identify and segment large vessel walls is demonstrated. PMID:29082087
Semiconductor cylinder fiber laser
NASA Astrophysics Data System (ADS)
Sandupatla, Abhinay; Flattery, James; Kornreich, Philipp
2015-12-01
We fabricated a fiber laser that uses a thin semiconductor layer surrounding the glass core as the gain medium. This is a completely new type of laser. The In2Te3 semiconductor layer is about 15-nm thick. The fiber laser has a core diameter of 14.2 μm, an outside diameter of 126 μm, and it is 25-mm long. The laser mirrors consist of a thick vacuum-deposited aluminum layer at one end and a thin semitransparent aluminum layer deposited at the other end of the fiber. The laser is pumped from the side with either light from a halogen tungsten incandescent lamp or a blue light emitting diode flash light. Both the In2Te3 gain medium and the aluminum mirrors have a wide bandwidth. Therefore, the output spectrum consists of a pedestal from a wavelength of about 454 to 623 nm with several peaks. There is a main peak at 545 nm. The main peak has an amplitude of 16.5 dB above the noise level of -73 dB.
NASA Astrophysics Data System (ADS)
Mizutani, Akio; Eto, Yohei; Kikuta, Hisao
2017-12-01
A grating coupler with a trapezoidal hole array was designed and fabricated for perfectly vertical light coupling between a single-mode optical fiber and a silicon waveguide on a silicon-on-insulator (SOI) substrate. The grating coupler with an efficiency of 53% was computationally designed at a 1.1-µm-thick buried oxide (BOX) layer. The grating coupler and silicon waveguide were fabricated on the SOI substrate with a 3.0-µm-thick BOX layer by a single full-etch process. The measured coupling efficiency was 24% for TE-polarized light at 1528 nm wavelength, which was 0.69 times of the calculated coupling efficiency for the 3.0-µm-thick BOX layer.
Hashimoto, Yuki; Saito, Wataru; Fujiya, Akio; Yoshizawa, Chikako; Hirooka, Kiriko; Mori, Shohei; Noda, Kousuke; Ishida, Susumu
2015-01-01
Purpose To investigate sequential post-operative thickness changes in inner and outer retinal layers in eyes with an idiopathic macular hole (MH). Methods Retrospective case series. Twenty-four eyes of 23 patients who had received pars plana vitrectomy (PPV) for the closure of MH were included in the study. Spectral domain optical coherence tomography C-scan was used to automatically measure the mean thickness of the inner and outer retinal layers pre-operatively and up to 6 months following surgery. The photoreceptor outer segment (PROS) length was measured manually and was used to assess its relationship with best-corrected visual acuity (BCVA). Results Compared with the pre-operative thickness, the inner layers significantly thinned during follow-up (P = 0.02), particularly in the parafoveal (P = 0.01), but not perifoveal, area. The post-operative inner layer thinning ranged from the ganglion cell layer to the inner plexiform layer (P = 0.002), whereas the nerve fiber layer was unaltered. Outer layer thickness was significantly greater post-operatively (P = 0.002), and especially the PROS lengthened not only in the fovea but also in the parafovea (P < 0.001). Six months after surgery, BCVA was significantly correlated exclusively with the elongated foveal PROS (R = 0.42, P = 0.03), but not with any of the other thickness parameters examined. Conclusions Following PPV for MH, retinal inner layers other than the nerve fiber layer thinned, suggestive of subclinical thickening in the inner layers where no cyst was evident pre-operatively. In contrast, retinal outer layer thickness significantly increased, potentially as a result of PROS elongation linking tightly with favorable visual prognosis in MH eyes. PMID:26291526
Sobon, Grzegorz; Duzynska, Anna; Świniarski, Michał; Judek, Jarosław; Sotor, Jarosław; Zdrojek, Mariusz
2017-01-01
In this work, we demonstrate a comprehensive study on the nonlinear parameters of carbon nanotube (CNT) saturable absorbers (SA) as a function of the nanotube film thickness. We have fabricated a set of four saturable absorbers with different CNT thickness, ranging from 50 to 200 nm. The CNTs were fabricated via a vacuum filtration technique and deposited on fiber connector end facets. Each SA was characterized in terms of nonlinear transmittance (i.e. optical modulation depth) and tested in a Thulium-doped fiber laser. We show, that increasing the thickness of the CNT layer significantly increases the modulation depth (up to 17.3% with 200 nm thick layer), which strongly influences the central wavelength of the laser, but moderately affects the pulse duration. It means, that choosing the SA with defined CNT thickness might be an efficient method for wavelength-tuning of the laser, without degrading the pulse duration. In our setup, the best performance in terms of bandwidth and pulse duration (8.5 nm and 501 fs, respectively) were obtained with 100 nm thick CNT layer. This is also, to our knowledge, the first demonstration of a fully polarization-maintaining mode-locked Tm-doped laser based on CNT saturable absorber. PMID:28368014
Leaf spring made of fiber-reinforced resin
NASA Technical Reports Server (NTRS)
Hori, J.
1986-01-01
A leaf spring made of a matrix reinforced by at least two types of reinforcing fibers with different Young's modulus is described in this Japanese patent. At least two layers of reinforcing fibers are formed by partially arranging the reinforcing fibers toward the direction of the thickness of the leaf spring. A mixture of different types of reinforced fibers is used at the area of boundary between the two layers of reinforced fibers. The ratio of blending of each type of reinforced fiber is frequently changed to eliminate the parts where discontinuous stress may be applied to the leaf spring. The objective of this invention is to prevent the rapid change in Young's modulus at the boundary area between each layer of reinforced fibers in the leaf spring.
Lee, Haeng-Jin; Kang, Tae-Seen; Kwak, Baek-Soo; Jo, Young-Joon; Kim, Jung-Yeul
2017-08-01
To evaluate the effects of panretinal photocoagulation on spectral domain optical coherence tomography measurements in diabetic retinopathy by comparing the thicknesses of the central macula, retinal nerve fiber layer, and ganglion cell layer, we used a Cirrus HD OCT® (Carl Zeiss Meditec, Dublin, CA, USA) in normal and diabetic retinopathy cohorts. We analyzed patients who visited our retinal clinic between May 2013 and July 2014. The patients were classified into four groups: normal (Group A), diabetes without diabetic retinopathy (Group B), severe nonproliferative or proliferative diabetic retinopathy (Group C), and at least 3 years after panretinal photocoagulation treatment (Group D). The mean thicknesses of the macula, retinal nerve fiber layer, and ganglion cell layer in each group were compared by measuring a macular cube 512 × 128 scan and an optic disc cube 200 × 200 scan twice. In total, 154 patients were enrolled. The mean thickness of the central macula in groups A to D was 257.2, 256.8, 257.4, and 255.6 µm, respectively, and did not differ significantly. The mean thickness of the RNFL in group A to D was 96.8, 96.5, 97.2, and 92.8 µm, respectively, and was significantly lower in group D (decreased in the inferior, superior, and nasal sectors, but increased in the temporal). The mean thickness of the ganglion cell layer was also significantly lower in group D (A, 84.5 µm; B, 84.4 µm; C, 82.5 µm; D, 78.5 µm). The mean thicknesses of the retinal nerve fiber and ganglion cell layers were decreased significantly in eyes with diabetic eye disease treated with panretinal photocoagulation compared to normal or eyes with diabetic eye disease that had not been laser-treated. Laser treatment might have altered the thickness of the inner layer of the retina, and such changes should be considered in diabetic retinopathy patients after panretinal photocoagulation treatment.
Ceramic Fiber Structures for Cryogenic Load-Bearing Applications
NASA Technical Reports Server (NTRS)
Jaskowiak, Martha H.; Eckel, Andrew J.
2009-01-01
This invention is intended for use as a load-bearing device under cryogenic temperatures and/or abrasive conditions (i.e., during missions to the Moon). The innovation consists of small-diameter, ceramic fibers that are woven or braided into devices like ropes, belts, tracks, or cables. The fibers can be formed from a variety of ceramic materials like silicon carbide, carbon, aluminosilicate, or aluminum oxide. The fiber architecture of the weave or braid is determined by both the fiber properties and the mechanical requirements of the application. A variety of weave or braid architectures is possible for this application. Thickness of load-bearing devices can be achieved by using either a 3D woven structure, or a layered, 2D structure. For the prototype device, a belt approximately 0.10 in. (0.25 cm) thick, and 3.0 in. (7.6 cm) wide was formed by layering and stitching a 2D aluminosilicate fiber weave.
Compression response of thick layer composite laminates with through-the-thickness reinforcement
NASA Technical Reports Server (NTRS)
Farley, Gary L.; Smith, Barry T.; Maiden, Janice
1992-01-01
Compression and compression-after-impact (CAI) tests were conducted on seven different AS4-3501-6 (0/90) 0.64-cm thick composite laminates. Four of the seven laminates had through-the-thickness (TTT) reinforcement fibers. Two TTT reinforcement methods, stitching and integral weaving, and two reinforcement fibers, Kevlar and carbon, were used. The remaining three laminates were made without TTT reinforcements and were tested to establish a baseline for comparison with the laminates having TTT reinforcement. Six of the seven laminates consisted of nine thick layers whereas the seventh material was composed of 46 thin plies. The use of thick-layer material has the potential for reducing structural part cost because of the reduced part count (layers of material). The compression strengths of the TTT reinforced laminates were approximately one half those of the materials without TTT reinforcements. However, the CAI strengths of the TTT reinforced materials were approximately twice those of materials without TTT reinforcements. The improvement in CAI strength is due to an increase in interlaminar strength produced by the TTT reinforcement. Stitched laminates had slightly higher compression and CAI strengths than the integrally woven laminates.
Performance of CAD/CAM fabricated fiber posts in oval-shaped root canals: An in vitro study.
Tsintsadze, Nino; Juloski, Jelena; Carrabba, Michele; Tricarico, Marella; Goracci, Cecilia; Vichi, Alessandro; Ferrari, Marco; Grandini, Simone
2017-10-01
To assess the push-out strength, the cement layer thickness and the interfacial nanoleakage of prefabricated fiber posts, CAD/CAM fiber posts and metal cast posts cemented into oval-shaped root canals. Oval-shaped post spaces were prepared in 30 single-rooted premolars. Roots were randomly assigned to three groups (n=10), according to the post type to be inserted: Group 1: Prefabricated fiber post (D.T. Light-Post X-RO Illusion); Group 2: Cast metal post; Group 3: CAD/CAM-fabricated fiber post (experimental fiber blocks). In Group 3, post spaces were sprayed with scan powder (VITA), scanned with an inEos 4.2 scanner, and fiber posts were milled using an inLab MC XL CAD/CAM milling unit. All posts were cemented using Gradia Core dual-cure resin cement in combination with Gradia core self-etching bond (GC). After 24 hours, the specimens were sectioned perpendicular to the long axis into six 1 mm-thick sections, which were differentiated by the root level. Sections from six roots per group were used to measure the cement thickness and subsequently for the thin-slice push-out test, whereas the sections from the remaining four teeth were assigned to interfacial nanoleakage test. The cement thickness around the posts was measured in micrometers (µm) on the digital images acquired with a digital microscope using the Digimizer software. Thin-slice push-out test was conducted using a universal testing machine at the crosshead speed of 0.5 mm/minute and the bond strength was expressed in megaPascals (MPa). The interfacial nanoleakage was observed under light microscope and quantified by scoring the depth of silver nitrate penetration along the post-cement-dentin interfaces. The obtained results were statistically analyzed by Kruskal-Wallis ANOVA, followed by the Dunn's Multiple Range test for post hoc comparisons. The level of significance was set at P< 0.05. Statistically significant differences were found among the groups in push-out bond strength, cement thickness and interfacial nanoleakage (P< 0.05). CAD/CAM-fabricated fiber posts achieved retention that was comparable to that of cast metal posts and significantly higher than that of prefabricated fiber posts. The cement layer thickness around CAD/CAM-fabricated fiber posts was significantly lower than around prefabricated fiber posts, but higher than that around cast metal posts. Root level was not a significant factor for push-out strength in any of the groups, whereas it significantly affected cement layer thickness only in the prefabricated fiber post group. No differences were observed in interfacial nanoleakage between CAD/CAM fabricated and prefabricated fiber posts, while nanoleakage recorded in cast metal posts was significantly lower. CAD/CAM fabricated fiber posts could represent a valid alternative to traditionally used posts in the restoration of endodontically-treated teeth with oval or wide root canals, offering the advantages of better esthetics, retention, and cement thickness values that are comparable to cast post and cores.
Cellulose fiber-enzyme composites fabricated through layer-by-layer nanoassembly.
Xing, Qi; Eadula, Sandeep R; Lvov, Yuri M
2007-06-01
Cellulose microfibers were coated with enzymes, laccase and urease, through layer-by-layer assembly by alternate adsorption with oppositely charged polycations. The formation of organized polyelectrolyte and enzyme multilayer films of 15-20 nm thickness was demonstrated by quartz crystal microbalance, zeta-potential analysis, and confocal laser scanning microscopy. These biocomposites retained enzymatic catalytic activity, which was proportional to the number of coated enzyme layers. For laccase-fiber composites, around 50% of its initial activity was retained after 2 weeks of storage at 4 degrees C. The synthesis of calcium carbonate microparticles on urease-fiber composites confirmed urease functionality and demonstrated its possible applications. This strategy could be employed to fabricate fiber-based composites with novel biological functions.
Guerini, H; Fermand, M; Godefroy, D; Feydy, A; Chevrot, A; Morvan, G; Gault, N; Drapé, J L
2012-02-01
The supraspinatus tendon is composed of 5 different layers consisting of intertwining bundles. On a front portion of the tendon, the layers become coated bundles which insert on the trochanter. At the insertion, the superficial or bursal surface of the tendon corresponding to the tendon fibers in contact with the subacromial bursa can be distinguished from the deep surface corresponding to the fibers in contact with the glenohumeral joint. A tendon tear may involve partial or total disruption of the tendon fibers and is called full-thickness tear if it affects the entire tendon, and partial-thickness tear if it involves only part of the tendon. Partial-thickness tears of the supraspinatus tendon include lesions of the superficial, deep and central surface or tendon delamination.A contrast enhanced examination requires injection of contrast agent into the joint (arthrography followed by computed tomography (CT) or magnetic resonance imaging (MRI)) to study the deep surface, and injection into the subacromial bursa (bursography followed by CT) to study the superficial surface. MRI and ultrasound (US) examination allow the study of these different tendon layers without the use of contrast agent (which is not possible at CT).
NASA Astrophysics Data System (ADS)
Seraji, Faramarz E.; Toutian, Golnoosh
This paper presents an analysis of the effect of temperature rise and hydrostatic pressure on microbending loss, refractive index change, and stress components of a double-coated optical fiber by considering coating material parameters such as Young's modulus and the Poisson ratio. It is shown that, when temperature rises, the microbending loss and refractive index changes would decrease with increase of thickness of primary coating layer and will increase after passing through a minima. Increase of thickness of secondary coating layer causes the microbending loss and refractive index changes to decrease. We have shown that the temperature rise affecting the fiber makes the microbending loss and refractive index decrease, linearly. At a particular temperature, the microbending loss takes negative values, due to tensile pressure applied on the fiber. The increase of Young's modulus and the Poisson ratio of primary coating would lower the microbending loss and refractive index change whereas in the secondary coating layer, the condition reverses.
Shi, Zhigang; Zhang, Yueping; Meek, Johannes; Qiao, Jiantian; Han, Victor Z.
2018-01-01
The distal valvula cerebelli is the most prominent part of the mormyrid cerebellum. It is organized in ridges of ganglionic and molecular layers, oriented perpendicular to the granular layer. We have combined intracellular recording and labelling techniques to reveal the cellular morphology of the valvula ridges in slice preparations. We have also locally ejected tracer in slices and in intact animals to examine its input fibers. The palisade dendrites and fine axon arbors of Purkinje cells are oriented in the horizontal plane of the ridge. The dendrites of basal efferent cells and large central cells are confined to the molecular layer, but are not planer. Basal efferent cell axons are thick, and join the basal bundle leaving the cerebellum. Large central cell axons are also thick, and traverse long distances in the transverse plane, with local collaterals in the ganglionic layer. Vertical cells and small central cells also have thick axons with local collaterals. The dendrites of Golgi cells are confined to the molecular layer, but their axon arbors are either confined to the granular layer or proliferate in both the granular and ganglionic layers. Dendrites of deep stellate cells are distributed in the molecular layer, with fine axon arbors in the ganglionic layer. Granule cell axons enter the molecular layer as parallel fibers without bifurcating. Climbing fibers run in the horizontal plane and terminate exclusively in the ganglionic layer. Our results confirm and extend previous studies and suggest a new concept of the circuitry of the mormyrid valvula cerebelli. PMID:18537139
Zou, Jingyun; Liu, Dandan; Zhao, Jingna; Hou, Ligan; Liu, Tong; Zhang, Xiaohua; Zhao, Yonghao; Zhu, Yuntian T; Li, Qingwen
2018-03-07
Carbon nanotube (CNT) fiber has not shown its advantage as next-generation light-weight conductor due to the large contact resistance between CNTs, as reflected by its low conductivity and ampacity. Coating CNT fiber with a metal layer like Cu has become an effective solution to this problem. However, the weak CNT-Cu interfacial bonding significantly limits the mechanical and electrical performances. Here, we report that a strong CNT-Cu interface can be formed by introducing a Ni nanobuffer layer before depositing the Cu layer. The Ni nanobuffer layer remarkably promotes the load and heat transfer efficiencies between the CNT fiber and Cu layer and improves the quality of the deposited Cu layer. As a result, the new composite fiber with a 2 μm thick Cu layer can exhibit a superhigh effective strength >800 MPa, electrical conductivity >2 × 10 7 S/m, and ampacity >1 × 10 5 A/cm 2 . The composite fiber can also sustain 10 000 times of bending and continuously work for 100 h at 90% ampacity.
Design of a novel multi channel photonic crystal fiber polarization beam splitter
NASA Astrophysics Data System (ADS)
Zhao, Yunyan; Li, Shuguang; Wang, Xinyu; Wang, Guangyao; Shi, Min; Wu, Junjun
2017-10-01
A kind of multi channel dual-core photonic crystal fiber polarization beam splitter is designed. We analyze the effects of the lattice parameters and the thickness of gold layer on the beam splitting by the finite element method. Numerical results show that the thickness of metal layer and the size of the air holes near the fiber cores are closely linked with the nature of the polarization beam splitter. We also obtain that extinction ratio can reach -73.87 dB at 1 . 55 μm wavelength and at 1 . 41 μm, 1 . 65 μm extinction ratio can reach 30.8978 dB and 31.1741 dB, respectively. The comparison of the effect on the characteristic of the photonic crystal fiber with coating no gold is also taken into account.
Design of an elastin-layered dermal regeneration template.
Mithieux, Suzanne M; Weiss, Anthony S
2017-04-01
We demonstrate a novel approach for the production of tunable quantities of elastic fibers. We also show that exogenous tropoelastin is rate-limiting for elastin synthesis regardless of the age of the dermal fibroblast donor. Additionally, we provide a strategy to further enhance synthesis by older cells through the application of conditioned media. We show that this approach delivers an elastin layer on one side of the leading dermal repair template for contact with the deep dermis in order to deliver prefabricated elastic fibers to a physiologically appropriate site during subsequent surgery. This system is attractive because it provides for the first time a viable path for sufficient, histologically detectable levels of patient elastin into full-thickness wound sites that have until now lacked this elastic underlayer. The scars of full thickness wounds typically lack elasticity. Elastin is essential for skin elasticity and is enriched in the deep dermis. This paper is significant because it shows that: (1) we can generate elastic fibers in tunable quantities, (2) tropoelastin is the rate-limiting component in elastin synthesis in vitro, (3) we can generate elastin fibers regardless of donor age, (4) we describe a novel approach to further increase the numbers and thickness of elastic fibers for older donors, (5) we improve on Integra Dermal Regeneration Template and generate a new hybrid biomaterial intended to subsequently surgically deliver these elastic fibers, (6) the elastic fiber layer is presented on the side of Integra that is intended for delivery into its physiologically appropriate site i.e. the deep dermis. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Gür Güngör, Sirel; Akman, Ahmet; Sarıgül Sezenöz, Almila; Tanrıaşıkı, Gülşah
2016-12-01
The presence of retinal nerve fiber layer (RNFL) split bundles was recently described in normal eyes scanned using scanning laser polarimetry and by histologic studies. Split bundles may resemble RNFL loss in healthy eyes. The aim of our study was to determine the prevalence of nerve fiber layer split bundles in healthy people. We imaged 718 eyes of 359 healthy persons with the spectral domain optical coherence tomography in this cross-sectional study. All eyes had intraocular pressure of 21 mmHg or less, normal appearance of the optic nerve head, and normal visual fields (Humphrey Field Analyzer 24-2 full threshold program). In our study, a bundle was defined as 'split' when there is localized defect not resembling a wedge defect in the RNFL deviation map with a symmetrically divided RNFL appearance on the RNFL thickness map. The classification was performed by two independent observers who used an identical set of reference examples to standardize the classification. Inter-observer consensus was reached in all cases. Bilateral superior split bundles were seen in 19 cases (5.29%) and unilateral superior split was observed in 15 cases (4.16%). In 325 cases (90.52%) there was no split bundle. Split nerve fiber layer bundles, in contrast to single nerve fiber layer bundles, are not common findings in healthy eyes. In eyes with normal optic disc appearance, especially when a superior RNFL defect is observed in RNFL deviation map, the RNLF thickness map and graphs should also be examined for split nerve fiber layer bundles.
Advanced Ceramic Matrix Composites with Multifunctional and Hybrid Structures
NASA Technical Reports Server (NTRS)
Singh, Mrityunjay; Morscher, Gregory N.
2004-01-01
Ceramic matrix composites are leading candidate materials for a number of applications in aeronautics, space, energy, and nuclear industries. Potential composite applications differ in their requirements for thickness. For example, many space applications such as "nozzle ramps" or "heat exchangers" require very thin (< 1 mm) structures whereas turbine blades would require very thick parts (> or = 1 cm). Little is known about the effect of thickness on stress-strain behavior or the elevated temperature tensile properties controlled by oxidation diffusion. In this study, composites consisting of woven Hi-Nicalon (trademark) fibers a carbon interphase and CVI SiC matrix were fabricated with different numbers of plies and thicknesses. The effect of thickness on matrix crack formation, matrix crack growth and diffusion kinetics will be discussed. In another approach, hybrid fiber-lay up concepts have been utilized to "alloy" desirable properties of different fiber types for mechanical properties, thermal stress management, and oxidation resistance. Such an approach has potential for the C(sub I)-SiC and SiC(sub f)-SiC composite systems. CVI SiC matrix composites with different stacking sequences of woven C fiber (T300) layers and woven SiC fiber (Hi-Nicalon (trademark)) layers were fabricated. The results will be compared to standard C fiber reinforced CVI SiC matrix and Hi-Nicalon reinforced CVI SiC matrix composites. In addition, shear properties of these composites at different temperatures will also be presented. Other design and implementation issues will be discussed along with advantages and benefits of using these materials for various components in high temperature applications.
NASA Astrophysics Data System (ADS)
Wang, Shubin; Zheng, Yu
2014-02-01
Hexagonal boron nitride (h-BN) coatings with different thickness were prepared on quartz fibers to improve mechanical properties of quartz fiber reinforced Sisbnd Osbnd Csbnd N composite. Scanning electron microscopy (SEM), push-out test and single edge notched beam (SENB) in three point bending test were employed to study morphology, interface shear strength and fracture toughness of the composite. The results showed that h-BN coatings changed the crack growth direction and weaken the interface shear strength efficiently. When the h-BN coating was 308.2 nm, the interface shear strength was about 5.2 MPa, which was about one-quarter of that of the sample without h-BN coatings. After the heating process for obtaining composite, the h-BN nanometer-sized grains would grow up to micron-sized hexagonal grains. Different thickness h-BN coatings had different structure. When the coatings were relatively thin, the hexagonal grains were single layer structure, and when the coatings were thicker, the hexagonal grains were multiple layer structure. This multiple layer interface phase would consume more power of cracks, thus interface shear strength of the composite decreased steadily with the increasing of h-BN coatings thickness. When the coating thickness was 238.8 nm, KIC reaches the peak value 3.8 MPa m1/2, which was more than two times of that of composites without h-BN coatings.
Nieves-Moreno, María; Martínez-de-la-Casa, José M; Morales-Fernández, Laura; Sánchez-Jean, Rubén; Sáenz-Francés, Federico; García-Feijoó, Julián
2018-01-01
To examine differences in individual retinal layer thicknesses measured by spectral domain optical coherence tomography (SD-OCT) (Spectralis®) produced with age and according to sex. Cross-sectional, observational study. The study was conducted in 297 eyes of 297 healthy subjects aged 18 to 87 years. In one randomly selected eye of each participant the volume and mean thicknesses of the different macular layers were measured by SD-OCT using the instrument's macular segmentation software. Volume and mean thickness of macular retinal nerve fiber layer (mRNFL), ganglion cell layer (GCL), inner plexiform layer (IPL), inner nuclear layer (INL), outer plexiform layer (OPL), outer nuclear layer (ONL), retinal pigmentary epithelium (RPE) and photoreceptor layer (PR). Retinal thickness was reduced by 0.24 μm for every one year of age. Age adjusted linear regression analysis revealed mean GCL, IPL, ONL and PR thickness reductions and a mean OPL thickness increase with age. Women had significantly lower mean GCL, IPL, INL, ONL and PR thicknesses and volumes and a significantly greater mRNFL volume than men. The thickness of most retinal layers varies both with age and according to sex. Longitudinal studies are needed to determine the rate of layer thinning produced with age.
African Descent and Glaucoma Evaluation Study (ADAGES)
Girkin, Christopher A.; Sample, Pamela A.; Liebmann, Jeffrey M.; Jain, Sonia; Bowd, Christopher; Becerra, Lida M.; Medeiros, Felipe A.; Racette, Lyne; Dirkes, Keri A.; Weinreb, Robert N.; Zangwill, Linda M.
2010-01-01
Objective To define differences in optic disc, retinal nerve fiber layer, and macular structure between healthy participants of African (AD) and European descent (ED) using quantitative imaging techniques in the African Descent and Glaucoma Evaluation Study (ADAGES). Methods Reliable images were obtained using stereoscopic photography, confocal scanning laser ophthalmoscopy (Heidelberg retina tomography [HRT]), and optical coherence tomography (OCT) for 648 healthy subjects in ADAGES. Findings were compared and adjusted for age, optic disc area, and reference plane height where appropriate. Results The AD participants had significantly greater optic disc area on HRT (2.06 mm2; P<.001) and OCT (2.47 mm2; P<.001) and a deeper HRT cup depth than the ED group (P<.001). Retinal nerve fiber layer thickness was greater in the AD group except within the temporal region, where it was significantly thinner. Central macular thickness and volume were less in the AD group. Conclusions Most of the variations in optic nerve morphologic characteristics between the AD and ED groups are due to differences in disc area. However, differences remain in HRT cup depth, OCT macular thickness and volume, and OCT retinal nerve fiber layer thickness independent of these variables. These differences should be considered in the determination of disease status. PMID:20457974
Integrated mechanics for the passive damping of polymer-matrix composites and composite structures
NASA Technical Reports Server (NTRS)
Saravanos, D. A.; Chamis, Christos C.
1991-01-01
Some recent developments on integrated damping mechanics for unidirectional composites, laminates, and composite structures are reviewed. Simplified damping micromechanics relate the damping of on-axis and off-axis composites to constituent properties, fiber volume ratio, fiber orientation, temperature, and moisture. Laminate and structural damping mechanics for thin composites are summarized. Discrete layer damping mechanics for thick laminates, including the effects of interlaminar shear damping, are developed and semianalytical predictions of modal damping in thick simply supported specialty composite plates are presented. Applications show the advantages of the unified mechanics, and illustrate the effect of fiber volume ratio, fiber orientation, structural geometry, and temperature on the damping. Additional damping properties for composite plates of various laminations, aspect ratios, fiber content, and temperature illustrate the merits and ranges of applicability of each theory (thin or thick laminates).
NASA Astrophysics Data System (ADS)
Liu, Kun; Xue, Meng; Jiang, Junfeng; Wang, Tao; Chang, Pengxiang; Liu, Tiegen
2018-03-01
A coupled plasmon waveguide resonance (CPWR) sensor based on metal/dielectric-coated step index multimode optical fiber is proposed. Theoretical simulations using the four-layer Fresnel equations based on a bi-dimensional optical fiber model were implemented on four structures: Ag-ZnO, Au-ZnO, Ag-TiO2 and Au-TiO2. By controlling the thickness of dielectric layer, we managed to manipulate the CPWR resonance wavelengths. When a CPWR resonance dip is in the short wavelength region, it is insensitive to the change of surrounding refractive index (SRI) and can be used as a reference to improve the sensing accuracy of surface plasmon resonance (SPR) mode. With the increase of the thickness of the dielectric layer, the CPWR resonance dips shift to longer wavelength and the corresponding sensitivities increase. When the 1st CPWR resonance wavelength is near 1550 nm and SRI is around 1.333, the sensitivities of four structures reach 1360.61 nm/RIU, 1375.76 nm/RIU, 1048.48 nm/RIU and 1015.15 nm/RIU, respectively. The values are close to that of the conventional SPR optical fiber sensor while the spectral bandwidths of the optical fiber CPWR sensors are narrower.
Simulated impact damage in a thick graphite/epoxy laminate using spherical indenters
NASA Technical Reports Server (NTRS)
Poe, C. C., Jr.
1988-01-01
The extent of fiber damage due to low-velocity impacts was determined for very thick graphite/epoxy laminates. The impacts were simulated by pressing spherical indenters against the laminates. After the forces were applied, the laminate was cut into smaller pieces so that each piece contained a test site. Then the pieces were deplied and the individual plies were examined to determine the extent of fiber damage. Broken fibers were found in the outer layers directly beneath the contact site. The locus of broken fibers resembled cracks. The cracks were more or less oriented in the direction of the fibers in the contiguous layers. The maximum length and depth of the cracks increased with increasing contact pressure and indenter diameter. The length and depth of the cracks were also predicted using maximum compression and shear stress criteria. The internal stresses were calculated using Hertz's law and Love's solution for pressure applied on part of the boundary of a semi-infinite body. The predictions and measurements were in good agreement.
Massera, J; Ahmed, I; Petit, L; Aallos, V; Hupa, L
2014-04-01
This paper investigates the effect of fiber drawing on the thermal and structural properties as well as on the glass reactivity of a phosphate glass in tris(hydroxymethyl)aminomethane-buffered (TRIS) solution and simulated body fluid (SBF). The changes induced in the thermal properties suggest that the fiber drawing process leads to a weakening and probable re-orientation of the POP bonds. Whereas the fiber drawing did not significantly impact the release of P and Ca, an increase in the release of Na into the solution was noticed. This was probably due to small structural reorientations occurring during the fiber drawing process and to a slight diffusion of Na to the fiber surface. Both the powders from the bulk and the glass fibers formed a Ca-P surface layer when immersed in SBF and TRIS. The layer thickness was higher in the calcium and phosphate supersaturated SBF than in TRIS. This paper for the first time presents the in vitro reactivity and optical response of a phosphate-based bioactive glass (PBG) fiber when immersed in SBF. The light intensity remained constant for the first 48h after which a decrease with three distinct slopes was observed: the first decrease between 48 and 200h of immersion could be correlated to the formation of the Ca-P layer at the fiber surface. After this a faster decrease in light transmission was observed from 200 to ~425h in SBF. SEM analysis suggested that after 200h, the surface of the fiber was fully covered by a thin Ca-P layer which is likely to scatter light. For immersion times longer than ~425h, the thickness of the Ca-P layer increased and thus acted as a barrier to the dissolution process limiting further reduction in light transmission. The tracking of light transmission through the PBG fiber allowed monitoring of the fiber dissolution in vitro. These results are essential in developing new bioactive fiber sensors that can be used to monitor bioresponse in situ. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Seraji, Faramarz E.; Toutian, Golnoush
2017-10-01
Fiber Bragg grating (FBG) of different configurations used as sensing devices are vulnerable to environmental factors, such as static pressures and thermal loading, which cause their characteristic Bragg reflecting wavelengths to up/down-shift. In this paper, by considering double-coated FBG with different primary and secondary coating materials, the effects of thermal loading and hydrostatic pressure on FBG with different coating-layer thicknesses are analyzed to find design criteria for controlling the Bragg wavelength shift. The obtained results of the analysis may be employed as criteria to design pressure and temperature sensors when using double-coated FBGs.
Effects of Constituents and Lay-up Configuration on Drop-Weight Tests of Fiber-Metal Laminates
NASA Astrophysics Data System (ADS)
Liu, Yanxiong; Liaw, Benjamin
2010-02-01
Impact responses and damage of various fiber-metal laminates were studied using a drop-weight instrument with the post-impact damage characteristics being evaluated through ultrasonic and mechanical sectioning techniques. The first severe failure induced by the low-velocity drop-weight impact occurred as delamination between the aluminum and fiber-epoxy layers at the non-impact side. It was followed by a visible shear crack in the outer aluminum layer on the non-impact face. Through-thickness shear cracks in the aluminum sheets and severe damage in the fiber laminated layers (including delamination between adjacent fiber-epoxy laminae with different fiber orientations) developed under higher energy impacts. The impact properties of fiber-metal laminates varied with different constituent materials and fiber orientations. Since it was punched through easily, the aramid-fiber reinforced fiber-metal laminates (ARALL) offered poorer impact resistance than the glass-fiber reinforced fiber-metal laminates (GLARE). Tougher and more ductile aluminum alloys improved the impact resistance. GLARE made of cross-ply prepregs provided better impact resistance than GLARE with unidirectional plies.
1979-11-01
over a 1 x 4 inch glass plate. A further problem has been that the surface over the ion diffused region is submerged 2 pm below that of the substrate...of varying mask openings (35, 45, 55, 65, 78, 85 pm ). The ion exchange processing time was varied using 20, 25, 35 and 40 minutes. We found that the...pattern is then overcoated with a thick layer of SiO 2 (lO0 pm thick). This thick layer and the SiO 2 substrate thus com- pletely surround the dopant
Farah, John; Sudarshanam, Venkatapuram S.
2003-05-13
Polymer substrates, in particular polyimide substrates, and polymer laminates for optical applications are described. Polyimide substrates are polished on one or both sides depending on their thickness, and single-layer or multi-layer waveguide structures are deposited on the polished polyimide substrates. Optical waveguide devices are machined by laser ablation using a combination of IR and UV lasers. A waveguide-fiber coupler with a laser-machined groove for retaining the fiber is also disclosed.
Kusano, Masahiro; Takizawa, Shota; Sakai, Tetsuya; Arao, Yoshihiko; Kubouchi, Masatoshi
2018-01-01
Since thermosetting resins have excellent resistance to chemicals, fiber reinforced plastics composed of such resins and reinforcement fibers are widely used as construction materials for equipment in chemical plants. Such equipment is usually used for several decades under severe corrosive conditions so that failure due to degradation may result. One of the degradation behaviors in thermosetting resins under chemical solutions is "corrosion-layer-forming" degradation. In this type of degradation, surface resins in contact with a solution corrode, and some of them remain asa corrosion layer on the pristine part. It is difficult to precisely measure the thickness of the pristine part of such degradation type materials by conventional pulse-echo ultrasonic testing, because the sound velocity depends on the degree of corrosion of the polymeric material. In addition, the ultrasonic reflection interface between the pristine part and the corrosion layer is obscure. Thus, we propose a pitch-catch method using a pair of normal and angle probes to measure four parameters: the thicknesses of the pristine part and the corrosion layer, and their respective sound velocities. The validity of the proposed method was confirmed by measuring a two-layer sample and a sample including corroded parts. The results demonstrate that the pitch-catch method can successfully measure the four parameters and evaluate the residual thickness of the pristine part in the corrosion-layer-forming sample. Copyright © 2017 Elsevier B.V. All rights reserved.
Li, Miaoling; Huisingh, Carrie; Messinger, Jeffrey; Dolz-Marco, Rosa; Ferrara, Daniela; Freund, K Bailey; Curcio, Christine A
2018-05-03
To systematically characterize histologic features of multiple chorioretinal layers in eyes with geographic atrophy, or complete retinal pigment epithelium (RPE) and outer retinal atrophy, secondary to age-related macular degeneration, including Henle fiber layer and outer nuclear layer; and to compare these changes to those in the underlying RPE-Bruch membrane-choriocapillaris complex and associated extracellular deposits. Geographic atrophy was delimited by the external limiting membrane (ELM) descent towards Bruch membrane. In 13 eyes, histologic phenotypes and/or thicknesses of Henle fiber layer, outer nuclear layer, underlying supporting tissues, and extracellular deposits at four defined locations on the non-atrophic and atrophic sides of the ELM descent were assessed and compared across other tissue layers, with generalized estimating equations and logit models. On the non-atrophic side of the ELM descent, distinct Henle fiber layer and outer nuclear layer became dyslaminated, cone photoreceptor inner segment myoids shortened, photoreceptor nuclei and mitochondria translocated inward, and RPE was dysmorphic. On the atrophic side of the ELM descent, all measures of photoreceptor health declined to zero. Henle fiber layer/outer nuclear layer thickness halved, and only Müller cells remained, in the absence of photoreceptors. Sub-RPE deposits remained, Bruch membrane thinned, and choriocapillaris density decreased. The ELM descent sharply delimits an area of marked gliosis and near-total photoreceptor depletion clinically defined as Geographic atrophy (or outer retinal atrophy), indicating severe and potentially irreversible tissue damage. Degeneration of supporting tissues across this boundary is gradual, consistent with steady age-related change and suggesting that RPE and Müller cells subsequently respond to a threshold of stress. Novel clinical trial endpoints should be sought at age-related macular degeneration stages before intense gliosis and thick deposits impede therapeutic intervention.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
Wanek, Justin; Blair, Norman P.; Chau, Felix Y.; Lim, Jennifer I.; Leiderman, Yannek I.; Shahidi, Mahnaz
2016-01-01
Purpose This article reports a method for en face optical coherence tomography (OCT) imaging and quantitative assessment of alterations in both thickness and reflectance of individual retinal layers at different stages of diabetic retinopathy (DR). Methods High-density OCT raster volume scans were acquired in 29 diabetic subjects divided into no DR (NDR) or non-proliferative DR (NPDR) groups and 22 control subjects (CNTL). A customized image segmentation method identified eight retinal layer interfaces and generated en face thickness maps and reflectance images for nerve fiber layer (NFL), ganglion cell and inner plexiform layers (GCLIPL), inner nuclear layer (INL), outer plexiform layer (OPL), outer nuclear layer (ONL), photoreceptor outer segment layer (OSL), and retinal pigment epithelium (RPE). Mean thickness and intensity values were calculated in nine macular subfields for each retinal layer. Results En face thickness maps and reflectance images of retinal layers in CNTL subjects corresponded to normal retinal anatomy. Total retinal thickness correlated negatively with age in nasal subfields (R ≤−0.31; P ≤ 0.03, N = 51). In NDR subjects, NFL and OPL thickness were decreased (P = 0.05), and ONL thickness was increased (P = 0.04) compared to CNTL. In NPDR subjects, GCLIPL thickness was increased in perifoveal subfields (P < 0.05) and INL intensity was higher in all macular subfields (P = 0.04) compared to CNTL. Conclusions Depth and spatially resolved retinal thickness and reflectance measurements are potential biomarkers for assessment and monitoring of DR. PMID:27409491
Modeling and characterization of through-the-thickness properties of 3D woven composites
NASA Technical Reports Server (NTRS)
Hartranft, Dru; Pravizi-Majidi, Azar; Chou, Tsu-Wei
1995-01-01
The through-the-thickness properties of three-dimensionally (3D) woven carbon/epoxy composites have been studied. The investigation aimed at the evaluation and development of test methodologies for the property characterization in the thickness direction, and the establishment of fiber architectures were studied: layer-to-layer Angle Interlock, through-the-thickness Orthogonal woven preform with surface pile was also designed and manufactured for the fabrication of tensile test coupons with integrated grips. All the preforms were infiltrated by the resin transfer molding technique. The microstructures of the composites were characterized along the warp and fill (weft) directions to determine the degree of yarn undulations, yarn cross-sectional shapes, and microstructural dimensions. These parameters were correlated to the fiber architecture. Specimens were designed and tested for the direct measurement of the through-the-thickness tensile, compressive and shear properties of the composites. Design optimization was conducted through the analysis of the stress fields within the specimen coupled with experimental verification. The experimentally-derived elastic properties in the thickness direction compared well with analytical predictions obtained from a volume averaging model.
Assessing posterior ocular structures in β-thalassemia minor.
Arifoglu, Hasan Basri; Kucuk, Bekir; Duru, Necati; Altunel, Orhan; Gulhan, Ahmet; Ozen, Mustafa; Aygun, Bilal; Atas, Mustafa
2018-02-01
The aim of this study was to investigate the effect of β-thalassemia minor on choroidal, macular, and peripapillary retinal nerve fiber layer thickness. To form the sample, we recruited 40 patients with β-thalassemia minor and 44 healthy participants. We used spectral-domain optical coherence tomography to take all measurements of ocular thickness, as well as measured intraocular pressure, axial length, and central corneal thickness. We later analyzed correlations of hemoglobin levels with ocular parameters. A statistically significant difference emerged between patients with β-thalassemia minor and the healthy controls in terms of mean values of subfoveal, nasal, and temporal choroidal thickness (p = 0.001, p = 0.016, and p = 0.010, respectively). Except for central macular thickness, differences in paracentral macular thicknesses between the groups were also significant (superior: p < 0.001, inferior: p = 0.007, temporal: p = 0.001, and nasal: p = 0.005). Also, no statistically significant differences were noted for retinal nerve fiber layer thickness between two groups. Mean values of subfoveal, nasal, temporal choroidal, and macular thickness for the four quadrants were significantly lower in patients with β-thalassemia minor than in healthy controls.
Ratiometric analysis of in vivo retinal layer thicknesses in multiple sclerosis
NASA Astrophysics Data System (ADS)
Bhaduri, Basanta; Nolan, Ryan M.; Shelton, Ryan L.; Pilutti, Lara A.; Motl, Robert W.; Boppart, Stephen A.
2016-09-01
We performed ratiometric analysis of retinal optical coherence tomography images for the first time in multiple sclerosis (MS) patients. The ratiometric analysis identified differences in several retinal layer thickness ratios in the cohort of MS subjects without a history of optic neuritis (ON) compared to healthy control (HC) subjects, and there was no difference in standard retinal nerve fiber layer thickness (RNFLT). The difference in such ratios between HC subjects and those with mild MS-disability, without a difference in RNFLT, further suggests the possibility of using layer ratiometric analysis for detecting early retinal changes in MS. Ratiometric analysis may be useful and potentially more sensitive for detecting disease changes in MS.
NASA Astrophysics Data System (ADS)
Xia, Hongyi; Steele, Charles R.; Puria, Sunil
2018-05-01
The gerbil basilar membrane (BM) differs from other mammalian BMs in that the lower collagen-fiber layer of the pectinate zone (PZ) forms an arch, the upper fiber layer is flat, and ground substance separates the two layers. The role of this arch has been unknown, but can be elucidated by models. In the standard simple beam model (SBM), the upper and lower collagen-fiber layers of the BM are represented as a single layer in both the PZ and the arcuate zone (AZ). In our new arch-beam model (ABM), the upper fiber layer is flat, the lower layer forms an arch in the PZ, and the two layers combine to form the flat portion of the BM in the AZ. This design is incorporated into a 3D finite-element tapered-box model of the cochlea with viscous fluid. We find in the model that the PZ rotates as a rigid body, so its specific properties have little influence, while the AZ thickness and collagen volume fraction primarily determine passive BM mechanics.
Mansberger, Steven L; Menda, Shivali A; Fortune, Brad A; Gardiner, Stuart K; Demirel, Shaban
2017-02-01
To characterize the error of optical coherence tomography (OCT) measurements of retinal nerve fiber layer (RNFL) thickness when using automated retinal layer segmentation algorithms without manual refinement. Cross-sectional study. This study was set in a glaucoma clinical practice, and the dataset included 3490 scans from 412 eyes of 213 individuals with a diagnosis of glaucoma or glaucoma suspect. We used spectral domain OCT (Spectralis) to measure RNFL thickness in a 6-degree peripapillary circle, and exported the native "automated segmentation only" results. In addition, we exported the results after "manual refinement" to correct errors in the automated segmentation of the anterior (internal limiting membrane) and the posterior boundary of the RNFL. Our outcome measures included differences in RNFL thickness and glaucoma classification (i.e., normal, borderline, or outside normal limits) between scans with automated segmentation only and scans using manual refinement. Automated segmentation only resulted in a thinner global RNFL thickness (1.6 μm thinner, P < .001) when compared to manual refinement. When adjusted by operator, a multivariate model showed increased differences with decreasing RNFL thickness (P < .001), decreasing scan quality (P < .001), and increasing age (P < .03). Manual refinement changed 298 of 3486 (8.5%) of scans to a different global glaucoma classification, wherein 146 of 617 (23.7%) of borderline classifications became normal. Superior and inferior temporal clock hours had the largest differences. Automated segmentation without manual refinement resulted in reduced global RNFL thickness and overestimated the classification of glaucoma. Differences increased in eyes with a thinner RNFL thickness, older age, and decreased scan quality. Operators should inspect and manually refine OCT retinal layer segmentation when assessing RNFL thickness in the management of patients with glaucoma. Copyright © 2016 Elsevier Inc. All rights reserved.
Durable high strength cement concrete topping for asphalt roads
NASA Astrophysics Data System (ADS)
Vyrozhemskyi, Valerii; Krayushkina, Kateryna; Bidnenko, Nataliia
2017-09-01
Work on improving riding qualities of pavements by means of placing a thin cement layer with high roughness and strength properties on the existing asphalt pavement were conducted in Ukraine for the first time. Such pavement is called HPCM (High Performance Cementitious Material). This is a high-strength thin cement-layer pavement of 8-9 mm thickness reinforced with metal or polymer fiber of less than 5 mm length. Increased grip properties are caused by placement of stone material of 3-5 mm fraction on the concrete surface. As a result of the research, the preparation and placement technology of high-strength cement thin-layer pavement reinforced with fiber was developed to improve friction properties of existing asphalt pavements which ensures their roughness and durability. It must be emphasized that HPCM is a fundamentally new type of thin-layer pavement in which a rigid layer of 10 mm thickness is placed on a non-rigid base thereby improving riding qualities of asphalt pavement at any season of a year.
Retinal Nerve Fiber Layer Thickness in Children With ADHD.
Hergüner, Arzu; Alpfidan, İsmail; Yar, Ahmet; Erdoğan, Erkan; Metin, Özge; Sakarya, Yaşar; Hergüner, Sabri
2018-05-01
The current study aims to compare retinal nerve fiber layer (RNFL) thickness, macular thickness, and macular volume between children with ADHD and a control group. The study group included children with ADHD and the control group consisted of age- and gender-matched participants without any psychiatric disorder. In all participants, RNFL thickness, macular thickness, and macular volume were measured by using spectral domain-optical coherence tomography (SD-OCT). ADHD symptom severity was evaluated by using parent-report measures, including Conners' Parent Rating Scale-Revised: Short Form (CPRS-R: S) and the Strengths and Difficulties Questionnaire: Parent Form (SDQ: P). We compared 90 eyes of 45 children with ADHD and 90 eyes of 45 controls. ADHD group had significantly lower RNFL thickness only in nasal quadrant than the controls. The remaining RNFL quadrants, macular thickness, and volume were not significantly different between groups. There was a reverse correlation between RNFL thickness and ADHD symptom severity. This is the first study examining the RNFL thickness in ADHD. Our findings showed that nasal RNFL thickness was lower, indicating reduced unmyelinated axons in the retina of children with ADHD. The results of this study support the evidence that ADHD involves a lag in cortical maturation and this is measurable in the retina.
Shi, Yi Wei; Ito, Kentaro; Matsuura, Yuji; Miyagi, Mitsunobu
2005-11-01
We report on low-loss multiwavelength laser delivery of hollow optical fiber in a wide wavelength region, from the visible to the infrared. Improved methods of liquid-phase coating were used to fabricate the hollow fiber with inner films of a silver and a cyclic olefin polymer (COP) layer. The surface roughness of the silver layer was reduced dramatically by pretreatment on the inner glass surface with an SnCl2 solution. The COP layer roughness was also decreased by using an ambient atmosphere of tetrahydrofuran (THF) solvent during the COP layer formation. Owing to the smooth surfaces, hollow fiber with optimum COP film thickness for CO2 laser light simultaneously yields low losses for a Er:YAG laser and a red pilot beam. The power durability of CO2 and Er:YAG lasers, as well as the loss properties for the pilot beam, is demonstrated.
Springelkamp, Henriët; Lee, Kyungmoo; Wolfs, Roger C W; Buitendijk, Gabriëlle H S; Ramdas, Wishal D; Hofman, Albert; Vingerling, Johannes R; Klaver, Caroline C W; Abràmoff, Michael D; Jansonius, Nomdo M
2014-11-20
We determined the glaucoma screening performance of regional optical coherence tomography (OCT) layer thickness measurements in the peripapillary and macular region, in a population-based setting. Subjects (n = 1224) in the Rotterdam Study underwent visual field testing (Humphrey Field Analyzer) and OCT of the macula and optic nerve head (Topcon 3-D OCT-1000). We determined the mean thicknesses of the retinal nerve fiber layer (RNFL), retinal ganglion cell layer (RGCL), and inner plexiform layer for regions-of-interest; thus, defining a series of OCT parameters, using the Iowa Reference Algorithms. Reference standard was the presence of glaucomatous visual field loss (GVFL); controls were subjects without GVFL, an intraocular pressure (IOP) of 21 mm Hg or less, and no positive family history for glaucoma. We calculated the area under the receiver operating characteristics curve (AUCs) and the sensitivity at 97.5% specificity for each parameter. After excluding 23 subjects with an IOP > 21 mm Hg and 73 subjects with a positive family history for glaucoma, there were 1087 controls and 41 glaucoma cases. Mean RGCL thickness in the inferior half of the macular region showed the highest AUC (0.85; 95% confidence interval [CI] 0.77-0.92) and sensitivity (53.7%; 95% CI, 38.7-68.0%). The mean thickness of the peripapillary RNFL had an AUC of 0.77 (95% CI, 0.69-0.85) and a sensitivity of 24.4% (95% CI, 13.7-39.5%). Macular RGCL loss is at least as common as peripapillary RNFL abnormalities in population-based glaucoma cases. Screening for glaucoma using OCT-derived regional thickness identifies approximately half of those cases of glaucoma as diagnosed by perimetry. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
Transmission properties of dielectric-coated hollow optical fibers based on stainless tube
NASA Astrophysics Data System (ADS)
Iwai, Katsumasa; Takaku, Hiroyuki; Miyagi, Mitsunobu; Shi, Yi-Wei; Zhu, Xiao-Song; Matsuura, Yuji
2018-02-01
Stainless pipe is used as the supporting tube for the infrared hollow fiber to obtain high durability and strong mechanical strength. In order to reduce roughness of inner surface of stainless tubes which causes the additional transmission loss, an acrylic-silicon resin material is used as a buffer layer to the inner wall of stainless tube for a low-loss characteristic. For the dielectric inner-coating layer, cyclic olefin polymer (COP) is used to lower the transmission loss. The COP layer is formed by using liquid-phase coating method. The hollow fiber with optimized COP inner film thickness for CO2 laser light were fabricated and reasonable transmission loss was demonstrated.
Fast detection of humidity with a subwavelength-diameter fiber taper coated with gelatin film.
Zhang, Lei; Gu, Fuxing; Lou, Jingyi; Yin, Xuefeng; Tong, Limin
2008-08-18
A subwavelength-diameter tapered optical fiber coated with gelatin layer for fast relative humidity (RH) sensing is reported. The sensing element is composed of a 680-nm-diameter fiber taper coated with a 80-nm-thickness 8-mm-length gelatin layer, and is operated at a wavelength of 1550 nm. When exposed to moisture, the change in refractive index of the gelatin layer changes the mode field of the guided mode of the coated fiber, and converts a portion of power from guided mode to radiation mode, resulting in RH-dependent loss for optical sensing. The sensor is operated within a wide humidity range (9-94% RH) with high sensitivity and good reversibility. Measured response time is about 70 ms, which is one or two orders of magnitude faster than other types of RH sensors relying on conventional optical fibers or films.
Saini, VK; Gupta, Saroj; Sharma, Anjali
2014-01-01
ABSTRACT Purpose: To evaluate the normative data of macular thickness and retinal nerve fiber layer thickness (RNFL) among normal subjects using spectral domain optical coherence tomography (OCT). Materials and methods: Normal subjects presenting to a tertiary medical hospital were included in the study. All patient underwent clinical examination followed by study of macular thickness and RN FL thick ness by spectral domain Topc on OCT. The data was collected and analyzed for variations in gender and age. The data was also compared with available literature. Results: Total numbers of patients enrolled in the study were 154 (308 eyes). Numbers of males were 79 (158 eyes) and numbers of females were 75 (150 eyes). The mean age among males was 42.67 ± 12.15 years and mean age among females was 42.88 ± 11.73 years. Overall the mean mac ular thickness (central 1 mm zone) with SD - OCT was 241.75 ± 17.3 microns. The mean macular volume was 7.6 cu. mm ± 0.33. On analysis of the RNFL thickness, we observed that the RNFL was thickest in the inferior quadrant (138.58) followed by superior (122.30) nasal (116.32) and temporal quadrant (73.04). Gender-wise comparison of the data revealed no statistically significant difference for age, macular thickness parameters, volume and RFNL values except outer temporal thickness among males and females. No age-related difference was noted in the above parameters. On comparison with available norma tive data from India and elsewhere, we found significant variations with different machines. Conclusion: The study is the first to provide normative data using SD-OCT from central India. The data from spectral domain OCT correlated well with the values obtained from similar studies with SD - OCT. Values obtained from time domain OCT machines are different and are not comparable. How to cite this article: Agarwal P, Saini VK, Gupta S, Sharma A. Evaluation of Central Macular Thickness and Retinal Nerve Fiber Layer Thickness using Spectral Domain Optical Coherence Tomography in a Tertiary Care Hospital. J Curr Glaucoma Pract 2014;8(2):75-81. PMID:26997813
NASA Astrophysics Data System (ADS)
Sohn, Kyung-Rak; Song, Jae-Won
2002-03-01
Using a side-polished single-mode fiber covered with a polished LiNbO 3 overlay and an intermediate coupling layer, tunable fiber-optic comb filters are demonstrated. The device behaviors based on the modal properties of the fiber and the planar LiNbO 3 waveguide are analyzed by two dimensional beam propagation methods (2-D BPM) and discussed the role of an intermediate coupling layer in terms of coupling efficiency. We also show that the thermo-optic effects of this layer can be utilized to tune the comb filter. When the polished x-cut LiNbO 3 with 200 μm thickness is used as a multimode overlay waveguide, the comb output spectra with free spectral range of 4 nm are measured in 1550 nm wavelength range. The tuning rate as a function of the refractive index of an intermediate coupling layer, Δλ/ Δnb, is about -0.129 nm/-0.001. The experimental results are in good agreement with the calculated results.
Xu, Wenjie; Chen, Zhenyi; Chen, Na; Zhang, Heng; Liu, Shupeng; Hu, Xinmao; Wen, Jianxiang; Wang, Tingyun
2017-01-01
A taper-fiber SERS nanoprobe modified by gold nanoparticles (Au-NPs) with ultrathin alumina layers was fabricated and its ability to perform remote Raman detection was demonstrated. The taper-fiber nanoprobe (TFNP) with a nanoscale tip size under 80 nm was made by heated pulling combined with the chemical etching method. The Au-NPs were deposited on the TFNP surface with the electrostatic self-assembly technology, and then the TFNP was wrapped with ultrathin alumina layers by the atomic layer deposition (ALD) technique. The results told us that with the increasing thickness of the alumina film, the Raman signals decreased. With approximately 1 nm alumina film, the remote detection limit for R6G aqueous solution reached 10−6 mol/L. PMID:28245618
Arifoglu, Hasan Basri; Simavli, Huseyin; Midillioglu, Inci; Berk Ergun, Sule; Simsek, Saban
2017-01-01
To evaluate the ganglion cell complex (GCC) and retinal nerve fiber layer (RNFL) thickness in pigment dispersion syndrome (PDS) and pigmentary glaucoma (PG) with RTVue spectral domain optical coherence tomography (SD-OCT). A total of 102 subjects were enrolled: 29 with PDS, 18 with PG, and 55 normal subjects. Full ophthalmic examination including visual field analysis was performed. SD-OCT was used to analyze GCC superior, GCC inferior, and average RNFL thickness. To compare the discrimination capabilities, the areas under the receiver operating characteristic curves were assessed. Superior GCC, inferior GCC, and RNFL thickness values of patients with PG were statistically signicantly lower than those of patients with PDS (p < 0.001) and healthy individuals (p < 0.001 for all). No statistically significant difference was found between PDS and normal subjects in same parameters (p > 0.05). The SD-OCT-derived GCC and RNFL thickness parameters can be useful to discriminate PG from both PDS and normal subjects.
Tabassum, Rana; Gupta, Banshi D
2015-02-10
We analyze surface plasmon resonance-based fiber-optic sensor for sensing of small concentrations of hydrogen gas in the visible region of the electromagnetic spectrum. One of the two probes considered has multilayers of zinc oxide (ZnO) and palladium (Pd) while the other has layer of their composite over a silver coated unclad core of the fiber. The analysis is carried out for different volume fractions of palladium nanoparticles dispersed in zinc oxide host material in the nanocomposite layer. For the analysis, a Maxwell-Garnett model is adopted for calculating the dielectric function of a ZnO:Pd nanocomposite having nanoparticles of dimensions smaller than the wavelength of radiation used. The effects of the volume fraction of the nanoparticles in the nanocomposite and the thickness of the nanocomposite layer on the figure of merit of the sensor have been studied. The film thickness of the layer and the volume fraction of nanoparticles in the ZnO:Pd nanocomposite layer have been optimized to achieve the maximum value of the figure of merit of the sensor. It has been found that the figure of merit of the sensing probe coated with ZnO:Pd nanocomposite is more than twofold of the sensing probe coated with multilayers of Pd and ZnO over a silver coated unclad core of the fiber; hence, the sensor with a nanocomposite layer works better than that with multilayers of zinc oxide and palladium. The sensor can be used for online monitoring and remote sensing of hydrogen gas.
Interfacial Thickness Guidelines for SiC(Fiber)/SiC(Matrix) Composites
NASA Technical Reports Server (NTRS)
Hurst, Janet B.
1998-01-01
Researchers at the NASA Lewis Research Center have developed a guideline for the interface thickness necessary for SiC(Fiber)/SiC(Matrix) composites to demonstrate good composite properties. These composite materials have potential commercial applications for high-temperature structural components such as engine hot sections. Several samples of each were composed from three different small-diameter (less than 20 mm), polymer-derived SiC fibers that were woven into two-dimensional cloths and laid up as preforms. The preforms were treated with a chemical-vapor-infiltrated boron nitride layer as an interfacial coating on the fiber surfaces to provide the necessary debonding characteristics for successful composite behavior. Then, the preforms were filled with additional SiC as a matrix phase.
Microelectromechanical system pressure sensor integrated onto optical fiber by anodic bonding.
Saran, Anish; Abeysinghe, Don C; Boyd, Joseph T
2006-03-10
Optical microelectromechanical system pressure sensors based on the principle of Fabry-Perot interferometry have been developed and fabricated using the technique of silicon-to-silicon anodic bonding. The pressure sensor is then integrated onto an optical fiber by a novel technique of anodic bonding without use of any adhesives. In this anodic bonding technique we use ultrathin silicon of thickness 10 microm to bond the optical fiber to the sensor head. The ultrathin silicon plays the role of a stress-reducing layer, which helps the bonding of an optical fiber to silicon having conventional wafer thickness. The pressure-sensing membrane is formed by 8 microm thick ultrathin silicon acting as a membrane, thus eliminating the need for bulk silicon etching. The pressure sensor integrated onto an optical fiber is tested for static response, and experimental results indicate degradation in the fringe visibility of the Fabry-Perot interferometer. This effect was mainly due to divergent light rays from the fiber degrading the fringe visibility. This effect is demonstrated in brief by an analytical model.
Ghaemi, Ferial; Ahmadian, Ali; Yunus, Robiah; Ismail, Fudziah; Rahmanian, Saeed
2016-01-01
In the current study, carbon nanofibers (CNFs) were grown on a carbon fiber (CF) surface by using the chemical vapor deposition method (CVD) and the influences of some parameters of the CVD method on improving the mechanical properties of a polypropylene (PP) composite were investigated. To obtain an optimum surface area, thickness, and yield of the CNFs, the parameters of the chemical vapor deposition (CVD) method, such as catalyst concentration, reaction temperature, reaction time, and hydrocarbon flow rate, were optimized. It was observed that the optimal surface area, thickness, and yield of the CNFs caused more adhesion of the fibers with the PP matrix, which enhanced the composite properties. Besides this, the effectiveness of reinforcement of fillers was fitted with a mathematical model obtaining good agreement between the experimental result and the theoretical prediction. By applying scanning electronic microscope (SEM), transmission electron microscope (TEM), and Raman spectroscopy, the surface morphology and structural information of the resultant CF-CNF were analyzed. Additionally, SEM images and a mechanical test of the composite with a proper layer of CNFs on the CF revealed not only a compactness effect but also the thickness and surface area roles of the CNF layers in improving the mechanical properties of the composites. PMID:28344263
NASA Astrophysics Data System (ADS)
Gifford, Erika; Wang, Z.; Ramachandran, S.; Heflin, J. R.
2007-09-01
Ionic self-assembled multilayers (ISAMs) adsorbed on long period fiber gratings (LPGs) can serve as an inexpensive, robust, portable, biosensor platform. The ISAM technique is a layer-by-layer deposition technique that creates thin films on the nanoscale level. The combination of ISAMs with LPGs yields exceptional sensitivity of the optical fiber transmission spectrum. We have shown theoretically that the resonant wavelength shift for a thin-film coated LPG can be caused by the variation of the film's refractive index and/or the variation of the thickness of the film. We have experimentally demonstrated that the deposition of nm-thick ISAM films on LPGs induces shifts in the resonant wavelength of > 1.6 nm per nm of thin film. It has also been shown that the sensitivity of the LPG to the thickness of the ISAM film increases with increased film thickness. We have further demonstrated that ISAM-coated LPGs can function effectively as biosensors by using the biotin-streptavidin system and by using the Bacillus anthracis (Anthrax) antibody- PA (Protective Antigen) system. Experiments have been successfully performed in both air and solution, which illustrates the versatility of the biosensor. The results confirm that ISAM-LPGs yield a reusable, thermally-stable, and robust platform for designing and building efficient optical biosensors.
NASA Astrophysics Data System (ADS)
Li, Cheng; Peng, Xiaobin; Liu, Qianwen; Gan, Xin; Lv, Ruitao; Fan, Shangchun
2017-02-01
Thickness measurement plays an important role for characterizing optomechanical behaviors of graphene. From the view of graphene-based Fabry-Perot (F-P) sensors, a simple, nondestructive and in situ method of determining the thickness of nanothick graphene membranes was demonstrated by using optical fiber F-P interference. Few-layer/multilayer graphene sheets were suspendedly adhered onto the endface of a ferrule with a 125 µm inner diameter by van der Waals interactions to construct micro F-P cavities. Along with the Fresnel’s law and complex index of refraction of the membrane working as a light reflector of an F-P interferometer, the optical reflectivity of graphene was modeled to investigate the effects of light wavelength and temperature. Then the average thickness of graphene membranes were extracted by F-P interference demodulation, and yielded a very strong cross-correlation coefficient of 99.95% with the experimental results observed by Raman spectrum and atomic force microscope. The method could be further extended for determining the number of layers of other 2D materials.
Method of Fabricating a Composite Apparatus
NASA Technical Reports Server (NTRS)
Wilkie, W. Keats (Inventor); Bryant, Robert G. (Inventor); Fox, Robert L. (Inventor); Hellbaum, Richard F. (Inventor); High, James W. (Inventor); Jalink, Antony, Jr. (Inventor)
2007-01-01
A method for fabricating a piezoelectric macro-fiber composite actuator comprises making a piezoelectric fiber sheet by providing a plurality of wafers of piezoelectric material, bonding the wafers together with an adhesive material to from a stack of alternating layers of piezoelectric material and adhesive material, and cutting through the stack in a direction substantially parallel to the thickness of the stack and across the alternating layers of piezoelectric material and adhesive material to provide at least one piezoelectric fiber sheet having two sides comprising a plurality of piezoelectric fibers in juxtaposition to the adhesive material. The method further comprises bonding two electrically conductive films to the two sides of the piezoelectric fiber sheet. At least one conductive film has first and second conductive patterns formed thereon which are electrically isolated from one another and in electrical contact with the piezoelectric fiber sheet.
Dada, Tanuj; Behera, Geeta; Agarwal, Anand; Kumar, Sanjeev; Sihota, Ramanjit; Panda, Anita
2010-01-01
To study the effect of cataract extraction on the retinal nerve fiber layer (RNFL) thickness, and assessment by scanning laser polarimetry (SLP), with variable corneal compensation (GDx VCC), at the glaucoma service of a tertiary care center in North India. Thirty-two eyes of 32 subjects were enrolled in the study. The subjects underwent RNFL analysis by SLP (GDx VCC) before undergoing phacoemulsification cataract extraction with intraocular lens (IOL) implantation (Acrysof SA 60 AT) four weeks following cataract surgery. The RNFL thickness parameters evaluated both before and after surgery included temporal, superior, nasal, inferior, temporal (TSNIT) average, superior average, inferior average, and nerve fiber index (NFI). The mean age of subjects was 57.6 +/- 11.7 years (18 males, 14 females). Mean TSNIT average thickness (microm) pre- and post-cataract surgery was 49.2 +/- 14.1 and 56.5 +/- 7.6 ( P = 0.001). There was a statistically significant increase in RNFL thickness parameters (TSNIT average, superior average, and inferior average) and decrease in NFI post-cataract surgery as compared to the baseline values. Mean NFI pre- and post-cataract surgery was 41.3 +/- 15.3 and 21.6 +/- 11.8 ( P = 0.001). Measurement of RNFL thickness parameters by scanning laser polarimetry is significantly altered following cataract surgery. Post the cataract surgery, a new baseline needs to be established for assessing the longitudinal follow-up of a glaucoma patient. The presence of cataract may lead to an underestimation of the RNFL thickness, and this should be taken into account when analyzing progression in a glaucoma patient.
Hybrid Aluminum and Natural Fiber Composite Structure for Crash Safety Improvement
NASA Astrophysics Data System (ADS)
Helaili, S.; Chafra, M.; Chevalier, Y.
There is a growing interest on pedestrian's protection in automotive safety standards. Pedestrians head impact is one of the most important tests. In this paper, a hybrid composite structure made from natural fiber and aluminum, which improve the head protection when impact is taken place, is presented. The structure is made from a honeycomb composite made from unidirectional and woven composites and a thin aluminum layer. A head impact model is developed. The number of hexagonal layers is fixed and the thickness of the aluminum layer of the honeycomb structure is varied. The specific absorption energy is then calculated.
Skin aging in patients with acquired immunodeficiency syndrome.
de Aquino Favarato, Grace Kelly Naves; da Silva, Aline Cristina Souza; Oliveira, Lívia Ferreira; da Fonseca Ferraz, Mara Lúcia; de Paula Antunes Teixeira, Vicente; Cavellani, Camila Lourencini
2016-10-01
To evaluate the histomorphometric skin changes over aging patients with autopsied acquired immunodeficiency syndrome (AIDS). In 29 skin fragments of autopsied elderly (older than 50 years) and nonelderly patients with AIDS, epidermal thickness, the number of layers, the diameter of cells, the percentage of collagen and elastic fibers in the dermis, and the number and morphology of Langerhans cells were assessed. Statistical analysis was performed by SigmaStat 2.03 program. The thickness of the epidermis (92.55 × 158.94 μm), the number of layers (7 × 9 layers), and the diameter of the cells (13.27 × 17.6 μm) were statistically lower among the elderly. The quantity of collagen fibers (9.68 × 14.11%) and elastic fibers (11.89 × 15.31%) was also significantly lower in the elderly. There was a decrease in total (10.61 × 12.38 cel/mm(2)) and an increase in immature Langerhans cells (6.31 × 4.98 cel/mm(2)) in elderly patients with AIDS. The aging of the skin of patients with AIDS is amended in different histomorphometric aspects, the epidermis constituents suffer less pronounced changes in normal aging, and the dermis has more intense changes in elastic fibers and collagen. Copyright © 2016 Elsevier Inc. All rights reserved.
Analytical and Experimental Characterization of Thick-Section Fiber-Metal Laminates
2013-06-01
individual metal layers as loading increases. The off-axis deformation properties of the prepreg layers were modeled by using equivalent constraint models...the degraded stiffness of the prepreg layer is found. At each loading step the stiffness properties of individual layers are calculated. These...predicts stress-strain curves on-axis, additional work is needed to study the local interactions between metal and prepreg layers as damage occurs in each
Active polymer materials for optical fiber CO2 sensors
NASA Astrophysics Data System (ADS)
Wysokiński, Karol; Filipowicz, Marta; Stańczyk, Tomasz; Lipiński, Stanisław; Napierała, Marek; Murawski, Michał; Nasiłowski, Tomasz
2017-04-01
CO2 optical fiber sensors based on polymer active materials are presented in this paper. Ethyl cellulose was proven to be a good candidate for a matrix material of the sensor, since it gives porous, thick and very sensitive layers. Low-cost sensors based on polymer optical fibers have been elaborated. Sensors have been examined for their sensitivity to CO2, temperature and humidity. Response time during cyclic exposures to CO2 have been also determined. Special layers exhibiting irreversible change of color during exposure to carbon dioxide have been developed. They have been verified for a possible use in smart food packaging.
NASA Technical Reports Server (NTRS)
Deshpande, Manohar D.; Dudley, Kenneth
2003-01-01
A simple method is presented to estimate the complex dielectric constants of individual layers of a multilayer composite material. Using the MatLab Optimization Tools simple MatLab scripts are written to search for electric properties of individual layers so as to match the measured and calculated S-parameters. A single layer composite material formed by using materials such as Bakelite, Nomex Felt, Fiber Glass, Woven Composite B and G, Nano Material #0, Cork, Garlock, of different thicknesses are tested using the present approach. Assuming the thicknesses of samples unknown, the present approach is shown to work well in estimating the dielectric constants and the thicknesses. A number of two layer composite materials formed by various combinations of above individual materials are tested using the present approach. However, the present approach could not provide estimate values close to their true values when the thicknesses of individual layers were assumed to be unknown. This is attributed to the difficulty in modelling the presence of airgaps between the layers while doing the measurement of S-parameters. A few examples of three layer composites are also presented.
Guthoff, Rudolf F; Wienss, Holger; Hahnel, Christian; Wree, Andreas
2005-07-01
Evaluation of a new method to visualize distribution and morphology of human corneal nerves (Adelta- and C-fibers) by means of fluorescence staining, confocal laser scanning microscopy, and 3-dimensional (3D) reconstruction. Trephinates of corneas with a diagnosis of Fuchs corneal dystrophy were sliced into layers of 200 microm thickness using a Draeger microkeratome (Storz, Germany). The anterior lamella was stained with the Life/Dead-Kit (Molecular Probes Inc.), examined by the confocal laser scanning microscope "Odyssey XL," step size between 0.5 and 1 microm, and optical sections were digitally 3D-reconstructed. Immediate staining of explanted corneas by the Life/Dead-Kit gave a complete picture of the nerves in the central human cornea. Thin nerves running parallel to the Bowman layer in the subepithelial plexus perforate the Bowman layer orthogonally through tube-like structures. Passing the Bowman layer, Adelta- and C-fibers can be clearly distinguished by fiber diameter, and, while running in the basal epithelial plexus, by their spatial arrangement. Adelta-fibers run straight and parallel to the Bowman layer underneath the basal cell layer. C-fibers, after a short run parallel to the Bowman layer, send off multiple branches penetrating epithelial cell layers orthogonally, ending blindly in invaginations of the superficial cells. In contrast to C-fibers, Adelta-fibers show characteristic bulbous formations when kinking into the basal epithelial plexus. Ex-vivo fluorescence staining of the cornea and 3D reconstructions of confocal scans provide a fast and easily reproducible tool to visualize nerves of the anterior living cornea at high resolution. This may help to clarify gross variations of nerve fiber patterns under various clinical and experimental conditions.
Ristić, Davor; Rasoloniaina, Alphonse; Chiappini, Andrea; Féron, Patrice; Pelli, Stefano; Conti, Gualtiero Nunzi; Ivanda, Mile; Righini, Giancarlo C; Cibiel, Gilles; Ferrari, Maurizio
2013-09-09
Coatings of spherical optical microresonators are widely employed for different applications. Here the effect of the thickness of a homogeneous coating layer on the coupling of light from a tapered fiber to a coated microsphere has been studied. Spherical silica microresonators were coated using a 70SiO(2)- 30HfO(2) glass doped with 0.3 mol% Er(3+) ions. The coupling of a 1480 nm pump laser inside the sphere has been assessed using a tapered optical fiber and observing the 1530-1580 nm Er(3+) emission outcoupled to the same tapered fiber. The measurements were done for different coating thicknesses and compared with theoretical calculations to understand the relationship of the detected signal with the whispering gallery mode electric field profiles.
A computational analysis of the ballistic performance of light-weight hybrid composite armors
NASA Astrophysics Data System (ADS)
Grujicic, M.; Pandurangan, B.; Koudela, K. L.; Cheeseman, B. A.
2006-11-01
The ability of hybrid light-weight fiber-reinforced polymer-matrix composite laminate armor to withstand the impact of a fragment simulating projectile (FSP) is investigated using a non-linear dynamics transient computational analysis. The hybrid armor is constructed using various combinations and stacking sequences of a high-strength/high-stiffness carbon fiber-reinforced epoxy (CFRE) and a high-ductility/high-toughness Kevlar fiber-reinforced epoxy (KFRE) composite laminates of different thicknesses. The results obtained indicate that at a fixed thickness of the armor both the stacking sequence and the number of CFRE/KFRE laminates substantially affect the ballistic performance of the armor. Specifically, it is found that the armor consisting of one layer of KFRE and one layer of CFRE, with KFRE laminate constituting the outer surface of the armor, possesses the maximum resistance towards the projectile-induced damage and failure. The results obtained are rationalized using an analysis of the elastic wave reflection and transmission behavior at the inter-laminate and laminate/air interfaces.
Hong, Seung Woo; Lee, Seung Bum; Jee, Dong-Hyun; Ahn, Myung Douk
2016-09-01
The purpose of study was to measure the diagnostic utility of interocular retinal nerve fiber layer (RNFL) symmetry and interocular RNFL thickness comparison. Both eyes of 103 normal subjects and 106 glaucoma patients (31 patients with early glaucoma and 75 patients with moderate to severe glaucoma) received comprehensive ophthalmologic evaluation including visual field testing and optic disc scanning using optical coherence tomography. RNFL thickness values for 256 measurement points were rearranged according to a new reference line connecting the optic disc center and the foveola. The interocular RNFL thickness symmetry value and absolute and fractional interocular difference in RNFL thickness were calculated and compared between groups. Area under the receiver operating characteristic curves (AUROCs) were calculated and compared. Among the parameters reflecting whole RNFL status, the corrected interocular RNFL thickness symmetry exhibited the largest AUROCs at all glaucoma stages. RNFL thickness and absolute and fractional interocular difference in RNFL thickness exhibited largest AUROC in the inferotemporal area, regardless of glaucoma stage. In the early glaucoma group, absolute and fractional interocular RNFL thickness differences in the temporal and superotemporal areas exhibited equal to or larger AUROCs than RNFL thickness. The AUROCs for RNFL thickness were greater than those for absolute and fractional interocular RNFL thickness differences in the moderate to severe glaucoma group except in the nasal and temporal area. The corrected interocular RNFL thickness symmetry value is an effective diagnostic tool for glaucoma. Interocular comparison of RNFL thickness has good diagnostic performance and gives information about the RNFL beyond just the RNFL thickness itself.
Zhu, Shan; Pang, Fufei; Huang, Sujuan; Zou, Fang; Guo, Qiang; Wen, Jianxiang; Wang, Tingyun
2016-08-15
Atomic layer deposition (ALD) technology is introduced to fabricate a high sensitivity refractometer based on an adiabatic tapered optical fiber. Different thicknesses of titanium dioxide (TiO₂) nanofilm were coated around the tapered fiber precisely and uniformly under different deposition cycles. Attributed to the higher refractive index of the TiO₂ nanofilm compared to that of silica, an asymmetric Fabry-Perot (F-P) resonator could be constructed along the fiber taper. The central wavelength of the F-P resonator could be controlled by adjusting the thickness of the TiO₂ nanofilm. Such a F-P resonator is sensitive to changes in the surrounding refractive index (SRI), which is utilized to realize a high sensitivity refractometer. The refractometer developed by depositing 50.9-nm-thickness TiO₂ on the tapered fiber shows SRI sensitivity as high as 7096 nm/RIU in the SRI range of 1.3373-1.3500. Due to TiO₂'s advantages of high refractive index, lack of toxicity, and good biocompatibility, this refractometer is expected to have wide applications in the biochemical sensing field.
Chang, In Boem; Lee, Jeong Hyun
2017-01-01
Purpose: To evaluate changes in choroidal thickness in and outside the macula as a result of hemodialysis (HD) in patients with end-stage renal disease. Methods: Patients with end-stage renal disease treated with maintenance HD in the Dialysis Unit of Sanggye Paik Hospital, Seoul, South Korea, were included in this study. The choroidal thickness was measured in and outside the macula before and after HD (paired t-test). Choroidal thickness in the macula was measured at the foveal center and 1.5 mm temporal to the foveal center and outside the macula was measured at superior, inferior, and nasal area 3.5 mm from the optic disk margin. Peripapillary retinal nerve fiber layer thickness, intraocular pressure, central corneal thickness, and systemic parameters such as serum osmolarity and blood pressure (BP) were measured before and after HD (paired t-test). We divided patients into two groups, diabetic and nondiabetic groups to compare the changes in choroidal thickness. Patients with diabetes were subdivided into two groups: severe retinal change group and moderate retinal change group (Mann–Whitney test). Pearson's correlation test was used to evaluate the correlations between choroidal thickness and changes in serum osmolarity, BP, and body weight loss. Choroidal thickness and peripapillary retinal nerve fiber layer thickness were measured using spectral-domain optical coherence tomography. Results: Fifty-four eyes of 31 patients with end-stage renal disease were included. After HD, the mean intraocular pressure was significantly decreased from 14.8 ± 2.5 mmHg to 13.0 ± 2.6 mmHg (P < 0.001). Choroidal thickness was reduced in all areas (P < 0.001). The reduction in choroidal thickness correlated with body weight loss, decrease in serum osmolarity, and decrease in systolic BP (P < 0.05). In the diabetic group, the mean choroidal thickness changes were greater than those in the nondiabetic group (P < 0.05). The severe retinal change group showed greater changes in choroidal thickness in all areas (P < 0.05). Other factors that significantly decreased after HD included serum osmolarity, body weight, and systolic BP (all P < 0.001). The diabetic group showed greater changes in serum osmolarity and body weight (P < 0.001, P = 0.048, respectively). The measured overall changes in peripapillary retinal nerve fiber layer thickness or central corneal thickness were not statistically significant. Conclusion: Changes in body weight, serum osmolarity, and BP during HD may affect choroidal thickness in and outside the macula. PMID:27557086
NASA Astrophysics Data System (ADS)
Khan, Zeeshan; Shah, Rehan Ali; Islam, Saeed; Jan, Bilal; Imran, Muhammad; Tahir, Farisa
2016-10-01
Modern optical fibers require double-layer coating on the glass fiber to provide protection from signal attenuation and mechanical damage. The most important plastic resins used in wires and optical fibers are plastic polyvinyl chloride (PVC) and low-high density polyethylene (LDPE/HDPE), nylon and Polysulfone. In this paper, double-layer optical fiber coating is performed using melt polymer satisfying PTT fluid model in a pressure type die using wet-on-wet coating process. The assumption of fully developed flow of Phan-Thien-Tanner (PTT) fluid model, two-layer liquid flows of an immiscible fluid is modeled in an annular die, where the fiber is dragged at a higher speed. The equations characterizing the flow and heat transfer phenomena are solved exactly and the effects of emerging parameters (Deborah and slip parameters, characteristic velocity, radii ratio and Brinkman numbers on the axial velocity, flow rate, thickness of coated fiber optics, and temperature distribution) are reported in graphs. It is shown that an increase in the non-Newtonian parameters increase the velocity in the absence or presence of slip parameters which coincides with related work. The comparison is done with experimental work by taking λ → 0 (non-Newtonian parameter).
Khan, Zeeshan; Shah, Rehan Ali; Islam, Saeed; Jan, Bilal; Imran, Muhammad; Tahir, Farisa
2016-01-01
Modern optical fibers require double-layer coating on the glass fiber to provide protection from signal attenuation and mechanical damage. The most important plastic resins used in wires and optical fibers are plastic polyvinyl chloride (PVC) and low-high density polyethylene (LDPE/HDPE), nylon and Polysulfone. In this paper, double-layer optical fiber coating is performed using melt polymer satisfying PTT fluid model in a pressure type die using wet-on-wet coating process. The assumption of fully developed flow of Phan-Thien-Tanner (PTT) fluid model, two-layer liquid flows of an immiscible fluid is modeled in an annular die, where the fiber is dragged at a higher speed. The equations characterizing the flow and heat transfer phenomena are solved exactly and the effects of emerging parameters (Deborah and slip parameters, characteristic velocity, radii ratio and Brinkman numbers on the axial velocity, flow rate, thickness of coated fiber optics, and temperature distribution) are reported in graphs. It is shown that an increase in the non-Newtonian parameters increase the velocity in the absence or presence of slip parameters which coincides with related work. The comparison is done with experimental work by taking λ → 0 (non-Newtonian parameter). PMID:27708412
Khan, Zeeshan; Shah, Rehan Ali; Islam, Saeed; Jan, Bilal; Imran, Muhammad; Tahir, Farisa
2016-10-06
Modern optical fibers require double-layer coating on the glass fiber to provide protection from signal attenuation and mechanical damage. The most important plastic resins used in wires and optical fibers are plastic polyvinyl chloride (PVC) and low-high density polyethylene (LDPE/HDPE), nylon and Polysulfone. In this paper, double-layer optical fiber coating is performed using melt polymer satisfying PTT fluid model in a pressure type die using wet-on-wet coating process. The assumption of fully developed flow of Phan-Thien-Tanner (PTT) fluid model, two-layer liquid flows of an immiscible fluid is modeled in an annular die, where the fiber is dragged at a higher speed. The equations characterizing the flow and heat transfer phenomena are solved exactly and the effects of emerging parameters (Deborah and slip parameters, characteristic velocity, radii ratio and Brinkman numbers on the axial velocity, flow rate, thickness of coated fiber optics, and temperature distribution) are reported in graphs. It is shown that an increase in the non-Newtonian parameters increase the velocity in the absence or presence of slip parameters which coincides with related work. The comparison is done with experimental work by taking λ → 0 (non-Newtonian parameter).
Huang, Jehn-Yu; Pekmezci, Melike; Mesiwala, Nisreen; Kao, Andrew; Lin, Shan
2011-02-01
To evaluate the capability of the optic disc, peripapillary retinal nerve fiber layer (P-RNFL), macular inner retinal layer (M-IRL) parameters, and their combination obtained by Fourier-domain optical coherent tomography (OCT) in differentiating a glaucoma suspect from perimetric glaucoma. Two hundred and twenty eyes from 220 patients were enrolled in this study. The optic disc morphology, P-RNFL, and M-IRL were assessed by the Fourier-domain OCT (RTVue OCT, Model RT100, Optovue, Fremont, CA). A linear discriminant function was generated by stepwise linear discriminant analysis on the basis of OCT parameters and demographic factors. The diagnostic power of these parameters was evaluated with receiver operating characteristic (ROC) curve analysis. The diagnostic power in the clinically relevant range (specificity ≥ 80%) was presented as the partial area under the ROC curve (partial AROC). The individual OCT parameter with the largest AROC and partial AROC in the high specificity (≥ 80%) range were cup/disc vertical ratio (AROC = 0.854 and partial AROC = 0.142) for the optic disc parameters, average thickness (AROC = 0.919 and partial AROC = 0.147) for P-RNFL parameters, inferior hemisphere thickness (AROC = 0.871 and partial AROC = 0.138) for M-IRL parameters, respectively. The linear discriminant function further enhanced the ability in detecting perimetric glaucoma (AROC = 0.970 and partial AROC = 0.172). Average P-RNFL thickness is the optimal individual OCT parameter to detect perimetric glaucoma. Simultaneous evaluation on disc morphology, P-RNFL, and M-IRL thickness can improve the diagnostic accuracy in diagnosing glaucoma.
Mallow Fiber-Reinforced Epoxy Composites in Multilayered Armor for Personal Ballistic Protection
NASA Astrophysics Data System (ADS)
Nascimento, Lucio Fábio Cassiano; Louro, Luis Henrique Leme; Monteiro, Sergio Neves; Lima, Édio Pereira; da Luz, Fernanda Santos
2017-10-01
Lighter and less expensive polymer composites reinforced with natural fibers have been investigated as possible components of a multilayered armor system (MAS) for personal protection against high-velocity ammunition. Their ballistic performance was consistently found comparable with that of conventional Kevlar® synthetic aramid fiber. Among the numerous existing natural fibers with the potential for reinforcing polymer composites to replace Kevlar® in MAS, mallow fiber has not been fully investigated. Thus, the objective of this work is to evaluate the ballistic performance of epoxy composites reinforced with 30 vol.% of aligned mallow fibers as a second MAS layer backing a front ceramic plate. The results using high-velocity 7.62 ammunition show a similar indentation to a Kevlar® layer with the same thickness. An impedance matching calculation supports the similar ballistic performance of mallow fiber composite and Kevlar®. Reduced MAS costs associated with the mallow fiber composite are practical advantages over Kevlar®.
Park, Kyung-Ah; Kim, Yoon-Duck; Woo, Kyung In
2018-06-01
The purpose of our study was to assess changes in peripapillary retinal nerve fiber layer (RNFL) thickness after orbital wall decompression in eyes with dysthyroid optic neuropathy (DON). We analyzed peripapillary optical coherence tomography (OCT) images (Cirrus HD-OCT) from controls and patients with DON before and 1 and 6 months after orbital wall decompression. There was no significant difference in mean preoperative peripapillary retinal nerve fiber layer thickness between eyes with DON and controls. The superior and inferior peripapillary RNFL thickness decreased significantly 1 month after decompression surgery compared to preoperative values (p = 0.043 and p = 0.022, respectively). The global average, superior, temporal, and inferior peripapillary RNFL thickness decreased significantly 6 months after decompression surgery compared to preoperative values (p = 0.015, p = 0.028, p = 0.009, and p = 0.006, respectively). Patients with greater preoperative inferior peripapillary RNFL thickness tended to have better postoperative visual acuity at the last visit (p = 0.024, OR = 0.926). Our data revealed a significant decrease in peripapillary RNFL thickness postoperatively after orbital decompression surgery in patients with DON. We also found that greater preoperative inferior peripapillary RNFL thickness was associated with better visual outcomes. We suggest that RNFL thickness can be used as a prognostic factor for DON before decompression surgery.
Association of ABO blood groups and Rh factor with retinal and choroidal thickness.
Teberik, Kuddusi; Eski, Mehmet Tahir
2018-06-01
To evaluate if ABO blood group and Rh factor have an effect on retinal and choroidal thickness. This study was designed prospectively. Retinal nerve fiber layer, retinal, and choroidal thicknesses were measured with spectral-domain optical coherence tomography. Retinal and choroidal thickness measurements (one subfoveal, three temporal, and three nasal) were obtained at 500-μm intervals up to 1500 μm with the caliper system. In this study, 109 male and 151 female, 260 individuals in total were included. There were 125 subjects in group A, 29 in group B, 34 in group AB, and 72 in group O. Rh factor was positive in 194 subjects and negative in 66. There was no significant difference between the groups regarding age (p = 0.667). The groups did not show any statistical difference in retinal nerve fiber layer thickness. There was significant difference found for mean retinal thickness at temporal 1000 μm when four groups were compared (p = 0.037). No statistically significant difference was detected for the remaining retinal and choroidal sectoral regions. The groups did not statistically significantly differ concerning Rh factor (p > 0.05). Although we found a significant difference in retinal thickness in the temporal retina between group B with group A and group O, we suggest that both blood group and Rh factor have no effect on retinal and choroidal thickness.
Ho3+-doped AlF3-TeO2-based glass fibers for 2.1 µm laser applications
NASA Astrophysics Data System (ADS)
Wang, S. B.; Jia, Z. X.; Yao, C. F.; Ohishi, Y.; Qin, G. S.; Qin, W. P.
2017-05-01
Ho3+-doped AlF3-TeO2-based glass fibers based on AlF3-BaF2-CaF2-YF3-SrF2-MgF2-TeO2 glasses are fabricated by using a rod-in-tube method. The glass rod including a core and a thick cladding layer is prepared by using a suction method, where the thick cladding layer is used to protect the core from the effect of surface crystallization during the fiber drawing. By inserting the glass rod into a glass tube, the glass fibers with relatively low loss (~2.3 dB m-1 @ 1560 nm) are prepared. By using a 38 cm long Ho3+-doped AlF3-TeO2-based glass fiber as the gain medium and a 1965 nm fiber laser as the pump source, 2065 nm lasing is obtained for a threshold pump power of ~220 mW. With further increasing the pump power to ~325 mW, the unsaturated output power of the 2065 nm laser is about 82 mW and the corresponding slope efficiency is up to 68.8%. The effects of the gain fiber length on the lasing threshold, the slope efficiency, and the operating wavelength are also investigated. Our experimental results show that Ho3+-doped AlF3-TeO2-based glass fibers are promising gain media for 2.1 µm laser applications.
Seo, Sam; Lee, Chong Eun; Jeong, Jae Hoon; Park, Ki Ho; Kim, Dong Myung; Jeoung, Jin Wook
2017-03-11
To determine the influences of myopia and optic disc size on ganglion cell-inner plexiform layer (GCIPL) and peripapillary retinal nerve fiber layer (RNFL) thickness profiles obtained by spectral domain optical coherence tomography (OCT). One hundred and sixty-eight eyes of 168 young myopic subjects were recruited and assigned to one of three groups according to their spherical equivalent (SE) values and optic disc area. All underwent Cirrus HD-OCT imaging. The influences of myopia and optic disc size on the GCIPL and RNFL thickness profiles were evaluated by multiple comparisons and linear regression analysis. Three-dimensional surface plots of GCIPL and RNFL thickness corresponding to different combinations of myopia and optic disc size were constructed. Each of the quadrant RNFL thicknesses and their overall average were significantly thinner in high myopia compared to low myopia, except for the temporal quadrant (all Ps ≤0.003). The average and all-sectors GCIPL were significantly thinner in high myopia than in moderate- and/or low-myopia (all Ps ≤0.002). The average OCT RNFL thickness was correlated significantly with SE (0.81 μm/diopter, P < 0.001), axial length (-1.44 μm/mm, P < 0.001), and optic disc area (5.35 μm/mm 2 , P < 0.001) by linear regression analysis. As for the OCT GCIPL parameters, average GCIPL thickness showed a significant correlation with SE (0.84 μm/diopter, P < 0.001) and axial length (-1.65 μm/mm, P < 0.001). There was no significant correlation of average GCIPL thickness with optic disc area. Three-dimensional curves showed that larger optic discs were associated with increased average RNFL thickness and that more-myopic eyes were associated with decreased average GCIPL and RNFL thickness. Myopia can significantly affect GCIPL and RNFL thickness profiles, and optic disc size has a significant influence on RNFL thickness. The current OCT maps employed in the evaluation of glaucoma should be analyzed in consideration of refractive status and optic disc size.
Mrugacz, Malgorzata; Bakunowicz-Lazarczyk, Alina
2005-01-01
The aim of this study was to quantitatively assess and compare the thickness of the retinal nerve fiber layer (RNFL) in normal and glaucomatous eyes of children using the optical coherence tomograph. The mean RNFL thickness of normal eyes (n=26) was compared with that of glaucomatous eyes (n=26). The eyes were classified into diagnostic groups based on conventional ophthalmological physical examination, Humphrey 30-2 visual fields, stereoscopic optic nerve head photography, and optical coherence tomography. The mean RNFL was significantly thinner in glaucomatous eyes than in normal eyes: 95+/-26.3 and 132+/-24.5 microm, respectively. More specifically, the RNFL was significantly thinner in glaucomatous eyes than in normal eyes in the inferior quadrant: 87+/-23.5 and 122+/-24.2 microm, respectively. The mean and inferior quadrant RFNL thicknesses as measured by the optical coherence tomograph showed a statistically significant correlation with glaucoma. Optical coherence tomography may contribute to tracking of juvenile glaucoma progression. Copyright (c) 2005 S. Karger AG, Basel.
Dada, Tanuj; Behera, Geeta; Agarwal, Anand; Kumar, Sanjeev; Sihota, Ramanjit; Panda, Anita
2010-01-01
Purpose: To study the effect of cataract extraction on the retinal nerve fiber layer (RNFL) thickness, and assessment by scanning laser polarimetry (SLP), with variable corneal compensation (GDx VCC), at the glaucoma service of a tertiary care center in North India. Materials and Methods: Thirty-two eyes of 32 subjects were enrolled in the study. The subjects underwent RNFL analysis by SLP (GDx VCC) before undergoing phacoemulsification cataract extraction with intraocular lens (IOL) implantation (Acrysof SA 60 AT) four weeks following cataract surgery. The RNFL thickness parameters evaluated both before and after surgery included temporal, superior, nasal, inferior, temporal (TSNIT) average, superior average, inferior average, and nerve fiber index (NFI). Results: The mean age of subjects was 57.6 ± 11.7 years (18 males, 14 females). Mean TSNIT average thickness (μm) pre- and post-cataract surgery was 49.2 ± 14.1 and 56.5 ± 7.6 (P = 0.001). There was a statistically significant increase in RNFL thickness parameters (TSNIT average, superior average, and inferior average) and decrease in NFI post-cataract surgery as compared to the baseline values. Mean NFI pre- and post-cataract surgery was 41.3 ± 15.3 and 21.6 ± 11.8 (P = 0.001). Conclusions: Measurement of RNFL thickness parameters by scanning laser polarimetry is significantly altered following cataract surgery. Post the cataract surgery, a new baseline needs to be established for assessing the longitudinal follow-up of a glaucoma patient. The presence of cataract may lead to an underestimation of the RNFL thickness, and this should be taken into account when analyzing progression in a glaucoma patient. PMID:20689193
Broadband operation of rolled-up hyperlenses
NASA Astrophysics Data System (ADS)
Schwaiger, Stephan; Rottler, Andreas; Bröll, Markus; Ehlermann, Jens; Stemmann, Andrea; Stickler, Daniel; Heyn, Christian; Heitmann, Detlef; Mendach, Stefan
2012-06-01
This work is related to an earlier publication [Schwaiger , Phys. Rev. Lett.PRLTAO0031-900710.1103/PhysRevLett.102.163903 102, 163903 (2009)], where we demonstrated by means of fiber-based transmission measurements that rolled-up Ag-(In)GaAs multilayers represent three-dimensional metamaterials with a plasma edge which is tunable over the visible and near-infrared regime by changing the thickness ratio of Ag and (In)GaAs, and predicted by means of finite-difference time-domain simulations that hyperlensing occurs at this frequency-tunable plasma edge. In the present work we develop a method to measure reflection curves on these structures and find that they correspond to the same tunable plasma edge. We find that retrieving the effective parameters from transmission and reflection data fails, because our realized metamaterials exceed the single-layer thicknesses of 5nm, which we analyze to be the layer thickness limit for the applicability of effective parameter retrieval. We show that our realized structures nevertheless have the functionality of an effective metamaterial by supplying a detailed finite-difference time-domain study which compares light propagation through our realized structure (17-nm-thick Ag layers and 34-nm-thick GaAs layers) and light propagation through an idealized structure of the same total thickness but with very thin layers [2-nm-thick Ag layers and 4-nm-thick (In)GaAs layers]. In particular, our simulations predict broadband hyperlensing covering a large part of the visible spectrum for both the idealized and our realized structures.
Chemically modified IR-transparent fibers and their application as chemical sensors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kellner, R.A.
1993-12-31
With the advent of chalcogenide- (As-Se-Te), Silverhalide- (AgBrCl) and TeXAs-fibers, the optical window available for analytical chemistry was significantly extended into the MID- and FAR-IR range (2 to 20 {mu}m) recently. These fibers have been chemically modified in our laboratory at 10 cm-distances of their surfaces (A) by covering them with 10-100 {mu}m thick layers of a suitable polymer such as LDPE ({open_quotes}Thickfilm-Sensor{close_quotes}) and (B) by immobilizing specifically reacting enzyme-layers such as GOx ({open_quotes}Thinfilm-Sensor{close_quotes}). In the first case, where the penetration depth of the IR-beam is smaller than the thickness of the polymer layer, a sensor for the simultaneous inmore » situ-determination of chlorinated hydrocarbon traces in water down to 500 ppb could be developed and tested. In the second case, a system for the determination of glucose in complex aqueous solutions was developed, based on the catalytic oxidation of glucose to gluconic acid and hydrogen peroxide by the immobilized enzyme glucose oxidase (GOx) in the physiological range. The GOx-density at the fibers could be significantly enlarged by using S-Layers instead of silanes for immobilization. Secondly, a flow injection-approach was developed recently, which allowed for an even further increase of the enzyme density by separating the reaction- and detection-part of our sensor, using controlled pore glass as carrier for the GOx and tapered chalcogenide fibers for detection. With this system, which works perfectly linear in the physiological range also for urea (with urease) a practical (multi)enzyme-based IR-sensor system is presented for the first time.« less
Schuster, Alexander Karl-Georg; Fischer, Joachim Ernst; Vossmerbaeumer, Christine; Vossmerbaeumer, Urs
2016-10-01
Optical coherence tomography (OCT) allows quantitative image analysis of retinal tissue in vivo. Peripapillary retinal nerve fiber layer (pRNFL) thickness is widely used for evaluation of retinal nerve fiber rarefaction in several optic neuropathies. This study evaluates associations of pRNFL thickness in healthy adult subjects in order to evaluate influencing factors. A cross-sectional study was performed in a working-age population. Only eyes without detectable ocular pathologies were included in the analysis. Among analyzed systemic cardiovascular parameters were age, gender, body-mass index, mean arterial blood pressure, HbA1c, high- and low-density-lipoproteins, and triglycerides. A comprehensive ophthalmological examination including refraction, tonometry, keratometry, and central corneal thickness measurmentwas performed. In addition, pRNFL thickness was imaged by spectral-domain OCT. Univariable and multivariable associations of pRNFL thickness in all four quadrants and on average with systemic and ocular parameters were calculated using a generalized estimating equation model. Three hundred and six subjects were included. pRNFL thickness measurements showed a significant association with spherical equivalent: pRNFL thickness decreased with increasing myopia in all quadrants (multivariable regression coefficients Beta: superior: 1.16, 95 % CI [0.62;1.71], p < 0.001; temporal: 0.87, [0.33;1.41], p = 0.001; inferior: 1.80, [1.18;2.42], p < 0.001; nasal: 2.60, [2.01;3.20], p < 0.001) and on average (1.51, [1.20;1.82], p < 0.001). A thicker central cornea thickness was related to lower pRNFL in the superior (-0.05, [-0.10; -0.01], p = 0.01), the inferior quadrant (-0.05, [-0.10;0.00], p = 0.03) and on average (-0.04, [-0.07; -0.01], p = 0.02). All other parameters were not associated. Our findings highlight the importance of refraction when evaluating pRNFL thickness and its independence from other systemic parameters.
Properties of medium-density fiberboard produced in an oil-heated laboratory press
O. Suchsland; G.E. Woodson
1976-01-01
Medium-density fiberboards from pressurized double-disk refined fibers have a close correlation between layer density and layer dynamic modulus of elasticity. Density distribution over the thickness was readily controlled by manipulating platen temperature and applied pressure. Thus, overall modulus of elasticity could be adjusted. In contrast to modulus of elasticity...
Pazos, Marta; Dyrda, Agnieszka Anna; Biarnés, Marc; Gómez, Alicia; Martín, Carlos; Mora, Clara; Fatti, Gianluca; Antón, Alfonso
2017-08-01
To evaluate the accuracy of the macular retinal layer segmentation software of the Spectralis spectral-domain (SD) optical coherence tomography (OCT) device (Heidelberg Engineering, Inc., Heidelberg, Germany) to discriminate between healthy and early glaucoma (EG) eyes. Prospective, cross-sectional study. Forty EG eyes and 40 healthy controls were included. All participants were examined using the standard posterior pole and the peripapillary retinal nerve fiber layer (pRNFL) protocols of the Spectralis OCT device. Using an Early Treatment Diagnostic Retinopathy Study circle at the macular level, the automated retinal segmentation software was applied to determine thicknesses of the following parameters: total retinal thickness, inner retinal layer (IRL), macular retinal nerve fiber layer (mRNFL), macular ganglion cell layer (mGCL), macular inner plexiform layer (mIPL), macular inner nuclear layer (mINL), macular outer plexiform layer (mOPL), macular outer nuclear layer (mONL), photoreceptors (PR), and retinal pigmentary epithelium (RPE). The ganglion cell complex (GCC) was determined by adding the mRNFL, mGCL, and mIPL parameters and the ganglion cell layer-inner plexiform layer (mGCL-IPL) was determined by combining the mGCL and mIPL parameters. Thickness of each layer was compared between the groups, and the layer and sector with the best area under the receiver operating characteristic curve (AUC) were identified. Comparison of pRNFL, IRL, mRNFL, mGCL, mIPL, mGCC, mGCL-IPL, mINL, mOPL, mONL, PR, and RPE parameters and total retinal thicknesses between groups for the different areas and their corresponding AUCs. Peripapillary RNFL was significantly thinner in the EG group globally and in all 6 sectors assessed (P < 0.0005). For the macular variables, retinal thickness was significantly reduced in the EG group for total retinal thickness, mIRL, mRNFL, mGCL, and mIPL. The 2 best isolated parameters to discriminate between the 2 groups were pRNFL (AUC, 0.956) and mRNFL (AUC, 0.906). When mRNFL, mGCL, and mIPL measurements were combined (mGCC and mGCL plus mIPL), then its diagnostic performance improved (AUC, 0.940 and 0.952, respectively). Macular RNFL, mGCL-IPL, and mGCC measurements showed a high diagnostic capability to discriminate between healthy and EG participants. However, macular intraretinal measurements still have not overcome standard pRNFL parameters. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Retinal and Optic Nerve Degeneration in Patients with Multiple Sclerosis Followed up for 5 Years.
Garcia-Martin, Elena; Ara, Jose R; Martin, Jesus; Almarcegui, Carmen; Dolz, Isabel; Vilades, Elisa; Gil-Arribas, Laura; Fernandez, Francisco J; Polo, Vicente; Larrosa, Jose M; Pablo, Luis E; Satue, Maria
2017-05-01
To quantify retinal nerve fiber layer (RNFL) changes in patients with multiple sclerosis (MS) and healthy controls with a 5-year follow-up and to analyze correlations between disability progression and RNFL degeneration. Observational and longitudinal study. One hundred patients with relapsing-remitting MS and 50 healthy controls. All participants underwent a complete ophthalmic and electrophysiologic exploration and were re-evaluated annually for 5 years. Visual acuity (Snellen chart), color vision (Ishihara pseudoisochromatic plates), visual field examination, optical coherence tomography (OCT), scanning laser polarimetry (SLP), and visual evoked potentials. Expanded Disability Status Scale (EDSS) scores, disease duration, treatments, prior optic neuritis episodes, and quality of life (QOL; based on the 54-item Multiple Sclerosis Quality of Life Scale score). Optical coherence tomography (OCT) revealed changes in all RNFL thicknesses in both groups. In the MS group, changes were detected in average thickness and in the mean deviation using the GDx-VCC nerve fiber analyzer (Laser Diagnostic Technologies, San Diego, CA) and in the P100 latency of visual evoked potentials; no changes were detected in visual acuity, color vision, or visual fields. Optical coherence tomography showed greater differences in the inferior and temporal RNFL thicknesses in both groups. In MS patients only, OCT revealed a moderate correlation between the increase in EDSS and temporal and superior RNFL thinning. Temporal RNFL thinning based on OCT results was correlated moderately with decreased QOL. Multiple sclerosis patients exhibit a progressive axonal loss in the optic nerve fiber layer. Retinal nerve fiber layer thinning based on OCT results is a useful marker for assessing MS progression and correlates with increased disability and reduced QOL. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Tornow, Ralf P.; Odstrcilik, Jan; Mayer, Markus A.; Gazarek, Jiri; Jan, Jiri; Kubena, Tomas; Cernosek, Pavel
2013-01-01
The retinal ganglion axons are an important part of the visual system, which can be directly observed by fundus camera. The layer they form together inside the retina is the retinal nerve fiber layer (RNFL). This paper describes results of a texture RNFL analysis in color fundus photographs and compares these results with quantitative measurement of RNFL thickness obtained from optical coherence tomography on normal subjects. It is shown that local mean value, standard deviation, and Shannon entropy extracted from the green and blue channel of fundus images are correlated with corresponding RNFL thickness. The linear correlation coefficients achieved values 0.694, 0.547, and 0.512 for respective features measured on 439 retinal positions in the peripapillary area from 23 eyes of 15 different normal subjects. PMID:24454526
Kolar, Radim; Tornow, Ralf P; Laemmer, Robert; Odstrcilik, Jan; Mayer, Markus A; Gazarek, Jiri; Jan, Jiri; Kubena, Tomas; Cernosek, Pavel
2013-01-01
The retinal ganglion axons are an important part of the visual system, which can be directly observed by fundus camera. The layer they form together inside the retina is the retinal nerve fiber layer (RNFL). This paper describes results of a texture RNFL analysis in color fundus photographs and compares these results with quantitative measurement of RNFL thickness obtained from optical coherence tomography on normal subjects. It is shown that local mean value, standard deviation, and Shannon entropy extracted from the green and blue channel of fundus images are correlated with corresponding RNFL thickness. The linear correlation coefficients achieved values 0.694, 0.547, and 0.512 for respective features measured on 439 retinal positions in the peripapillary area from 23 eyes of 15 different normal subjects.
Macroscopic and histological investigation of guanaco footpads (Lama guanicoe, Müller 1776).
König, Horst Erich; Skewes, Oscar; Helmreich, Magda; Böck, Peter
2015-03-01
The surface of guanaco footpads is characterized by hairless skin with up to 4-mm-thick stratum corneum that protects from abrasion. The horny layer is pliable and elastic, and ensures firm contact with irregular ground. It is padded with a particular structure of the subcutaneous layer, the digital cushion. The flat cushions of each of the two digits are of elongated ovate shape, each about 45-mm long, up to 20-mm wide, and 8-mm thick. The cushions are lined by a 1-2-mm-thick capsule that resembles a tunica albuginea. The capsule consists of coarse collagen fibers, with elastic fibers absent. The cushion capsule and dermis approach each other, and fuse along a line that runs parallel to the longitudinal axes of cushion and digit. Loose connective tissue rich in elastic fibers and acidic glycosaminoglycans separates dermis and cushion capsule lateral to the narrow interconnecting zone. The cushion capsule encloses cloudy yellowish, gelatinous material. Microscopy shows bundles of elastic fibers in abundant mucinous matrix. Tightly gathered elastic bundles adjoin the inner surface of the capsule. Rough cords of elastic fibers branch out from there and traverse to the opposite side. The cushion is pressed flat, and elastic fibers are stretched when bearing weight. With relief of load, elastic fibers contract and reset the cushion's shape. Contractile cells are absent. A resistant capsule and easily malleable mucinous contents establish the functioning as a gel pad. Mucinous connective tissue between elastic fiber bundles contains abundant basophilic matrix. Hyaluronan, chondroitin sulfate, and dermatan sulfate are main matrix constituents. Spindle-shaped or stellate fibroblasts contain vimentin, S100 protein, and neuron specific enolase. Moprhology, staining characteristics and synthesis activities of these cells meet the criteria to be classified as myxoid cells. The connective tissue in guanaco digital cushions represents myxoid tissue. © 2014 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Panda, Satyajit; Ray, M. C.
2008-04-01
In this paper, a geometrically nonlinear dynamic analysis has been presented for functionally graded (FG) plates integrated with a patch of active constrained layer damping (ACLD) treatment and subjected to a temperature field. The constraining layer of the ACLD treatment is considered to be made of the piezoelectric fiber-reinforced composite (PFRC) material. The temperature field is assumed to be spatially uniform over the substrate plate surfaces and varied through the thickness of the host FG plates. The temperature-dependent material properties of the FG substrate plates are assumed to be graded in the thickness direction of the plates according to a power-law distribution while the Poisson's ratio is assumed to be a constant over the domain of the plate. The constrained viscoelastic layer of the ACLD treatment is modeled using the Golla-Hughes-McTavish (GHM) method. Based on the first-order shear deformation theory, a three-dimensional finite element model has been developed to model the open-loop and closed-loop nonlinear dynamics of the overall FG substrate plates under the thermal environment. The analysis suggests the potential use of the ACLD treatment with its constraining layer made of the PFRC material for active control of geometrically nonlinear vibrations of FG plates in the absence or the presence of the temperature gradient across the thickness of the plates. It is found that the ACLD treatment is more effective in controlling the geometrically nonlinear vibrations of FG plates than in controlling their linear vibrations. The analysis also reveals that the ACLD patch is more effective for controlling the nonlinear vibrations of FG plates when it is attached to the softest surface of the FG plates than when it is bonded to the stiffest surface of the plates. The effect of piezoelectric fiber orientation in the active constraining PFRC layer on the damping characteristics of the overall FG plates is also discussed.
NASA Astrophysics Data System (ADS)
Shang, Ya-na; Ni, Qing-yan; Ding, Ding; Chen, Na; Wang, Ting-yun
2015-01-01
In this paper, a partial discharge detection system is proposed using an optical fiber Fabry-Perot (FP) interferometric sensor, which is fabricated by photolithography. SU-8 photoresist is employed due to its low Young's modulus and potentially high sensitivity for ultrasound detection. The FP cavity is formed by coating the fiber end face with two layers of SU-8 so that the cavity can be controlled by the thickness of the middle layer of SU-8. Static pressure measurement experiments are done to estimate the sensing performance. The results show that the SU-8 based sensor has a sensitivity of 154.8 nm/kPa, which is much higher than that of silica based sensor under the same condition. Moreover, the sensor is demonstrated successfully to detect ultrasound from electrode discharge.
Dotan, Gad; Kesler, Anat; Naftaliev, Elvira; Skarf, Barry
2015-05-01
To report on the correlation of structural damage to the axons of the optic nerve and visual outcome following bilateral non-arteritic anterior ischemic optic neuropathy. A retrospective review of the medical records of 25 patients with bilateral sequential non-arteritic anterior ischemic optic neuropathy was performed. Outcome measures were peripapillary retinal nerve fiber layer thickness measured with the Stratus optical coherence tomography scanner, visual acuity and visual field loss. Median peripapillary retinal nerve fiber layer (RNFL) thickness, mean deviation (MD) of visual field, and visual acuity of initially involved NAION eyes (54.00 µm, -17.77 decibels (dB), 0.4, respectively) were comparable to the same parameters measured following development of second NAION event in the other eye (53.70 µm, p = 0.740; -16.83 dB, p = 0.692; 0.4, p = 0.942, respectively). In patients with bilateral NAION, there was a significant correlation of peripapillary RNFL thickness (r = 0.583, p = 0.002) and MD of the visual field (r = 0.457, p = 0.042) for the pairs of affected eyes, whereas a poor correlation was found in visual acuity of these eyes (r = 0.279, p = 0.176). Peripapillary RNFL thickness following NAION was positively correlated with MD of visual field (r = 0.312, p = 0.043) and negatively correlated with logMAR visual acuity (r = -0.365, p = 0.009). In patients who experience bilateral NAION, the magnitude of RNFL loss is similar in each eye. There is a greater similarity in visual field loss than in visual acuity between the two affected eyes with NAION of the same individual.
Wasyluk, Jaromir T; Jankowska-Lech, Irmina; Terelak-Borys, Barbara; Grabska-Liberek, Iwona
2012-03-01
We compared the parameters of retinal nerve fibre layer in patients with advanced glaucoma with the use of different OCT (Optical Coherence Tomograph) devices in relation to analogical measurements performed with GDx VCC (Nerve Fiber Analyzer with Variable Corneal Compensation) scanning laser polarimetry. Study subjects had advanced primary open-angle glaucoma, previously treated conservatively, diagnosed and confirmed by additional examinations (visual field, ophthalmoscopy of optic nerve, gonioscopy), A total of 10 patients were enrolled (9 women and 1 man), aged 18-70 years of age. Nineteen eyes with advanced glaucomatous neuropathy were examined. 1) Performing a threshold perimetry Octopus, G2 strategy and ophthalmoscopy of optic nerve to confirm the presence of advanced primary open-angle glaucoma; 2) performing a GDx VCC scanning laser polarimetry of retinal nerve fibre layer; 3) measuring the retinal nerve fibre layer thickness with 3 different optical coherence tomographs. The parameters of the retinal nerve fibre layer thickness are highly correlated between the GDx and OCT Stratus and 3D OCT-1000 devices in mean retinal nerve fibre layer thickness, retinal nerve fibre layer thickness in the upper sector, and correlation of NFI (GDx) with mean retinal nerve fibre layer thickness in OCT examinations. Absolute values of the retinal nerve fibre layer thickness (measured in µm) differ significantly between GDx and all OCT devices. Examination with OCT devices is a sensitive diagnostic method of glaucoma, with good correlation with the results of GDx scanning laser polarimetry of the patients.
Guclu, Orkut; Guclu, Hande; Huseyin, Serhat; Korkmaz, Selcuk; Yuksel, Volkan; Canbaz, Suat; Pelitli Gurlu, Vuslat
2018-06-23
To examine changes in retinal ganglion cell complex (GCC) and peripapillary retinal nerve fiber layer (RNFL) thicknesses by optical coherence tomography (OCT) in contralateral and ipsilatateral eyes of carotid artery stenosis (CAS) patients before and after carotid endarterectomy (CEA). Forty-two consecutive patients diagnosed with CAS (70-99% stenosis rate) who underwent CEA were included in this prospective cross-sectional study. The indication for CEA was based on the Asymptomatic Carotid Atherosclerosis Study. Doppler ultrasonography and computed tomography angiography were performed to calculate CAS. All the subjects underwent an ophthalmological examination, including best corrected visual acuity (BCVA), intraocular pressure (IOP) measurements, biomicroscopy, fundoscopy, and OCT before and after the surgery. The mean preoperative intraocular pressure was 15.2 ± 2.1 mmHg in the ipsilateral eye and 15.8 ± 2.7 in the contralateral eye. The mean postoperative intraocular pressure in the ipsilateral and contralateral eye was 18.6 ± 3.0 and 19.3 ± 3.8, respectively. The intraocular pressure was significantly higher in postoperative eyes (p = 0.0001). There was a statistically significant decrease in peripapillary RNFL thickness in superior quadrants postoperatively in ipsilateral eyes. The retinal GCC layer thickness was not significantly different before and after CEA in ipsilateral and contralateral eyes. Carotid endarterectomy results in thinning of the superior peripapillary RNFL thickness. To the best of our knowledge, this is the first study to examine peripapillary RNFL and GCC thicknesses before and after CEA.
An Assessment of Retinal Nerve Fiber Layer Thickness in Non-Diabetic Obese Children and Adolescents
Özen, Bediz; Öztürk, Hakan; Çatlı, Gönül; Dündar, Bumin
2018-01-01
Objective: Obesity affects almost all systems in the body. This includes the retinal nerve fibers which may be damaged due to a chronic inflammatory process. To determine changes in retinal nerve fiber layer (RNFL) thickness in non-diabetic children and adolescents using optical coherence tomography (OCT) and to evaluate the relationship between this change, metabolic risk factors and pubertal stage. Methods: Thirty-eight obese and 40 healthy children and adolescents aged 10-18 years were included in the study. RNFL measurements from the optic disk and all surrounding quadrants were obtained using OCT from both eyes of the individuals in the study groups. Correlations between RNFL thickness and age, auxological measurements, pubertal stage, systolic and diastolic blood pressure, homeostasis model assessment-insulin resistance (HOMA-IR) index and lipid values were investigated. Results: A general decrease was observed in RNFL thickness in obese subjects compared to the controls, the decrease being highest in the inferior quadrant, although these differences were not statistically significant (p>0.05). RNFL thickness was negatively correlated with body mass index (BMI) standard deviation score (SDS) in both groups (control group r=-0.345, p=0.029; obese group r=-0.355, p=0.022). Significant negative correlations were determined between diastolic blood pressure, HOMA-IR, low density lipoprotein cholesterol level and RNFL thickness (r=-0.366, p=0.024; r=-0.394, p=0.016; and r=-0.374, p=0.022, respectively) in the obese group, while there was no association between these parameters and RNFL thickness in the control group. Conclusion: In this cross-sectional study, no statistically significant difference in RNFL thicknesses between the obese and control groups was determined. However, RNFL thickness was found to decrease in both healthy and obese children as BMI-SDS values increased. Further prospective studies may be of benefit to determine whether the decrease in RNFL values might become more pronounced on long-term follow-up. PMID:28739552
Bhaduri, Basanta; Shelton, Ryan L; Nolan, Ryan M; Hendren, Lucas; Almasov, Alexandra; Labriola, Leanne T; Boppart, Stephen A
2017-11-01
Influence of diabetes mellitus (DM) and diabetic retinopathy (DR) on parafoveal retinal thicknesses and their ratios was evaluated. Six retinal layer boundaries were segmented from spectral-domain optical coherence tomography images using open-source software. Five study groups: (1) healthy control (HC) subjects, and subjects with (2) controlled DM, (3) uncontrolled DM, (4) controlled DR and (5) uncontrolled DR, were identified. The one-way analyses of variance (ANOVA) between adjacent study groups (i. e. 1 with 2, 2 with 3, etc) indicated differences in retinal thicknesses and ratios. Overall retinal thickness, ganglion cell layer (GCL) thickness, inner plexiform layer (IPL) thickness, and their combination (GCL+ IPL), appeared to be significantly less in the uncontrolled DM group when compared to controlled DM and controlled DR groups. Although the combination of nerve fiber layer (NFL) and GCL, and IPL thicknesses were not different, their ratio, (NFL+GCL)/IPL, was found to be significantly higher in the controlled DM group compared to the HC group. Comparisons of the controlled DR group with the controlled DM group, and with the uncontrolled DR group, do not show any differences in the layer thicknesses, though several significant ratios were obtained. Ratiometric analysis may provide more sensitive parameters for detecting changes in DR. Picture: A representative segmented OCT image of the human retina is shown. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Muscular innervation of the proximal duodenum of the guinea pig.
Iino, S
2000-10-01
We investigated the muscular structure and innervation of the gastroduodenal junction in the guinea pig. In the gastroduodenal junction, the innermost layer of the circular muscle contained numerous nerve fibers and terminals. Since this nerve network continued onto the deep muscular plexus (DMP) of the duodenum, we surmised that the numerous nerve fibers in the gastroduodenal junction were specialized DMP in the most proximal part of the duodenum. The innermost layer containing many nerve fibers was about 1,000 microm in length and 100 microm in thickness in the proximal duodenum. This layer contained numerous connective tissue fibers composed of collagen and elastic fibers. Five to 30 smooth muscle cells lay in contact with each other and were surrounded by fine connective tissue. The nerve fibers in the proximal duodenum contained nerve terminals immunoreactive for choline acetyltransferase, dynorphin, enkephalin, galanin, gastrin-releasing peptide, nitric oxide synthase, substance P, and vasoactive intestinal polypeptide. Adrenergic fibers which contained tyrosine hydroxylase immunoreactivity were rare in the proximal duodenum. In the innermost layer of the proximal duodenum, there were numerous c-Kit immunopositive cells that were in contact with nerve terminals. This study allowed us to clarify the specific architecture of the most proximal portion of the duodenum. The functional significance of the proximal duodenum in relation to the electrical connection and neural cooperation of the musculature between the antrum and the duodenum is also discussed.
Terahertz gas sensing based on time-domain-spectroscopy using a hollow-optical fiber gas cell
NASA Astrophysics Data System (ADS)
Suzuki, T.; Katagiri, T.; Matsuura, Y.
2018-02-01
Terahertz gas sensing system based on time-domain spectroscopy (THz-TDS) using a hollow-optical fiber gas cell is proposed. A hollow optical fiber functions as a long-path and low-volume gas cell and loading a dielectric layer on the inside of the fiber reduces the transmission loss and the dielectric layer also protects the metal layer of the fiber from deterioration. In the fabrication process, a polyethylene tube with a thin wall is drawn from a thick preform and a metal layer is formed on the outside of the tube. By using a 34-cm long fiber gas cell, NH3 gas with a concentration of 8.5 % is detected with a good SN ratio. However, the absorption peaks of NH3 and water vapor appeared at around 1.2 THz are not separated. To improve the frequency resolution in Fourier transformation, the time scan width that is decided by the scanning length of linear stage giving a time delay in the probing THz beam is enlarged. As a result, the absorption peaks at around 1.2 THz are successfully separated. In addition, by introducing a longer fiber gas cell of 60-cm length, the measurement sensitivity is improved and an absorption spectrum of NH3 gas with a concentration of 0.5 % is successfully detected.
Hua, Zanmei; Fang, Qiuyun; Sha, Xiangyin; Yang, Ruiming; Hong, Zuopeng
2015-03-01
Glaucoma is an eye disease that can lead to irreversible optic nerve damage and cause blindness. Optical coherence tomography (OCT) allows an early diagnosis of glaucoma by the measurements of the retinal nerve fiber and optic disc parameters. A retrospective study was designed to analyze the effects of the measurement of the retinal nerve fiber layer (RNFL) thickness and the optic disc tomography by spectral-domain OCT on the early diagnosis of suspected glaucoma and primary open angle glaucoma (POAG). This was a clinical case-control study. The RNFL thickness around the optic disc and optic disk tomographic parameters of the control (n = 51, 98 eyes), suspected glaucoma (n = 81, 146 eyes), and POAG groups (n = 55, 106 eyes) were measured by OCT. The parameters included superior, inferior, nasal and temporal mean RNFL thickness, disc area (DA), cup area (CA), rim area (RA), disc volume (DV), cup volume (CV), rim volume (RV), cup/disc area ratio (CA/DA), rim/disc area ratio (RA/DA), cup/disc volume ratio (CV/DV) and rim/disc volume ratio (RV/DV). Superior, nasal, and mean RNFL parameters, DA, CA,RA, DV, CV, CA/DA, RA/DA, CV/DV and RV/DV significantly differed among three groups by single-factorial ANOVA. Inferior and temporal RNFL thickness significantly differed between the control and POAG groups. No significant difference was observed in RV among three groups. In the POAG group, the maximum area under the ROC curve (AROC) of mean RNFL thickness was 0.845. The maximum AROC of optic disk parameters was RA/DA (0.998), followed by CA/DA (0.997). The AROC of CA, RA, CV, and DV were all > 0.900. OCT may serve as a useful diagnostic modality in distinguishing suspected glaucoma from POAG.
Perez, Claudio I; Chansangpetch, Sunee; Thai, Andy; Nguyen, Anh-Hien; Nguyen, Anwell; Mora, Marta; Nguyen, Ngoc; Lin, Shan C
2018-06-05
Evaluate the distribution and the color probability codes of the peripapillary retinal nerve fiber layer (RNFL) and macular ganglion cell-inner plexiform layer (GCIPL) thickness in a healthy Vietnamese population and compare them with the original color-codes provided by the Cirrus spectral domain OCT. Cross-sectional study. We recruited non-glaucomatous Vietnamese subjects and constructed a normative database for peripapillary RNFL and macular GCIPL thickness. The probability color-codes for each decade of age were calculated. We evaluated the agreement with Kappa coefficient (κ) between OCT color probability codes with Cirrus built-in original normative database and the Vietnamese normative database. 149 eyes of 149 subjects were included. The mean age of enrollees was 60.77 (±11.09) years, with a mean spherical equivalent of +0.65 (±1.58) D and mean axial length of 23.4 (±0.87) mm. Average RNFL thickness was 97.86 (±9.19) microns and average macular GCIPL was 82.49 (±6.09) microns. Agreement between original and adjusted normative database for RNFL was fair for average and inferior quadrant (κ=0.25 and 0.2, respectively); and good for other quadrants (range: κ=0.63-0.73). For macular GCIPL κ agreement ranged between 0.39 and 0.69. After adjusting with the normative Vietnamese database, the percent of yellow and red color-codes increased significantly for peripapillary RNFL thickness. Vietnamese population has a thicker RNFL in comparison with Cirrus normative database. This leads to a poor color-code agreement in average and inferior quadrant between the original and adjusted database. These findings should encourage to create a peripapillary RNFL normative database for each ethnicity.
Zhu, Shan; Pang, Fufei; Huang, Sujuan; Zou, Fang; Guo, Qiang; Wen, Jianxiang; Wang, Tingyun
2016-01-01
Atomic layer deposition (ALD) technology is introduced to fabricate a high sensitivity refractometer based on an adiabatic tapered optical fiber. Different thicknesses of titanium dioxide (TiO2) nanofilm were coated around the tapered fiber precisely and uniformly under different deposition cycles. Attributed to the higher refractive index of the TiO2 nanofilm compared to that of silica, an asymmetric Fabry–Perot (F-P) resonator could be constructed along the fiber taper. The central wavelength of the F-P resonator could be controlled by adjusting the thickness of the TiO2 nanofilm. Such a F-P resonator is sensitive to changes in the surrounding refractive index (SRI), which is utilized to realize a high sensitivity refractometer. The refractometer developed by depositing 50.9-nm-thickness TiO2 on the tapered fiber shows SRI sensitivity as high as 7096 nm/RIU in the SRI range of 1.3373–1.3500. Due to TiO2’s advantages of high refractive index, lack of toxicity, and good biocompatibility, this refractometer is expected to have wide applications in the biochemical sensing field. PMID:27537885
NASA Astrophysics Data System (ADS)
Zhang, Xiaolin; Tang, Jianguo; Li, Haidong; Wang, Yao; Wang, Xinzhi; Wang, Yanxin; Huang, Linjun; Belfiore, Laurence A.
2018-04-01
This work demonstrated red light emitting nano-PVP fibers that incorporated with novel three-layer nanostructure of Ag@SiO2@Eu(tta)3phen nanoparticles (Ag@SiO2@Eu(tta)3phen-NPs), and the hybrid nano-PVP fibers were fabricated via a remarkably simple electrostatic spinning method. For Ag@SiO2@Eu(tta)3phen-NPs, the thickness of SiO2 is optimized to obtain the maximum luminescent intensity, as results, the optimized thickness of SiO2 is 20 nm. And the corresponding luminescent intensity (612 nm) of the Ag@SiO2@Eu(tta)3phen-NPs is enhanced up to 10 times compared with the pure Eu(tta)3phen complex, which indicates that with 20 nm SiO2 thickness, the localized surface plasmon resonance (LSPR) effect of Ag@SiO2 exhibits highest performance for enhancing luminescence. Moreover, the luminescent PVP fibers emit bright red light under the fluorescence microscope, which definitely confirms that the microenvironment provided by PVP polymer is absolutely suitable for the fluorescent composites.
Szczurek, Anna; Barcikowski, Michał; Leluk, Karol; Babiarczuk, Bartosz; Kaleta, Jerzy; Krzak, Justyna
2017-08-25
The modification of carbon fibers for improving adhesion between fibers and an epoxy resin in composite materials has become the focus of attention. In this work the carbon fiber coating process has been devised in a way preventing the stiffening and clumping of fibers. To improve interactions between coated fibers and a resin in composites, four types of silica coatings with different organic functional groups (3-aminopropyl-coating 1, 3-mercaptopropyl-coating 2, 2-(3,4-epoxycyclohexyl) ethyl-coating 3, methyl-coating 4) were obtained. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) were used to distinguish the changes of a carbon fibers surface after coating deposition. The thickness of the obtained coatings, including the diversity of thickness, was determined by transmission electron microscopy (TEM). The increase in surface free energy (SFE) of modified fibers, including the distinction between the polar and dispersive parts, was examined by wettability measurements using a tensometric test. The developed coating preparation process allowed to cover fibers separately with nanoscale silica layers, which changed their morphology. The introduction of organic functional groups resulted in surface free energy changes, especially an increase in specific polar surface energy components.
Barcikowski, Michał; Leluk, Karol; Babiarczuk, Bartosz; Kaleta, Jerzy
2017-01-01
The modification of carbon fibers for improving adhesion between fibers and an epoxy resin in composite materials has become the focus of attention. In this work the carbon fiber coating process has been devised in a way preventing the stiffening and clumping of fibers. To improve interactions between coated fibers and a resin in composites, four types of silica coatings with different organic functional groups (3-aminopropyl–coating 1, 3-mercaptopropyl–coating 2, 2-(3,4-epoxycyclohexyl) ethyl–coating 3, methyl–coating 4) were obtained. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) were used to distinguish the changes of a carbon fibers surface after coating deposition. The thickness of the obtained coatings, including the diversity of thickness, was determined by transmission electron microscopy (TEM). The increase in surface free energy (SFE) of modified fibers, including the distinction between the polar and dispersive parts, was examined by wettability measurements using a tensometric test. The developed coating preparation process allowed to cover fibers separately with nanoscale silica layers, which changed their morphology. The introduction of organic functional groups resulted in surface free energy changes, especially an increase in specific polar surface energy components. PMID:28841187
NASA Technical Reports Server (NTRS)
Tran, Huy Kim; Sawko, Paul M.
1992-01-01
Silicon carbide (SiC) fiber is a material that may be used in advanced thermal protection systems (TPS) for future aerospace vehicles. SiC fiber's mechanical properties depend greatly on the presence or absence of sizing and its microstructure. In this research, silicon dioxide is found to be present on the surface of the fiber. Electron Spectroscopy for Chemical Analysis (ESCA) and Scanning Electron Microscopy (SEM) show that a thin oxide layer (SiO2) exists on the as-received fibers, and the oxide thickness increases when the fibers are exposed to high temperature. ESCA also reveals no evidence of Si-C bonding on the fiber surface on both as-received and heat treated fibers. The silicon oxide layer is thought to signal the decomposition of SiC bonds and may be partially responsible for the degradation in the breaking strength observed at temperatures above 400 C. The variation in electrical resistivity of the fibers with increasing temperature indicates a transition to a higher band gap material at 350 to 600 C. This is consistent with a decomposition of SiC involving silicon oxide formation.
Interface control and mechanical property improvements in silicon carbide/titanium composites
NASA Technical Reports Server (NTRS)
Brewer, W. D.; Unnam, J.
1982-01-01
Several composite systems made of titanium matrix reinforced with silicon carbide fiber were investigated to obtain a better understanding of composite-degradation mechanisms and to develop techniques to minimize loss of mechanical properties during fabrication and in service. Emphasis was on interface control by fiber or matrix coatings. X-ray diffraction studies on planar samples showed that the formation of titanium silicides was greatly inhibited by the presence of aluminum or Ti3A1 layers at the fiber-matrix interface, with the Ti3A1 being more effective in reducing the reactions. Fiber studies showed that coating the fiber with a 1-micron-thick layer of aluminum improved the as-fabricated strength of a stoichiometric SiC fiber and reduced the fiber degradation during exposure to composite-fabrication conditions. Applying an interfacial barrier by coating the matrix foils instead of the fibers was found to be an effective method for improving composite strength. Reducing the fabrication temperature also resulted in significant improvements in composite strengths. Good-quality, well-consolidated composites were fabricated at temperatures well below those currently used for SiC-Ti composite fabrication.
Miniature all-silica optical fiber pressure sensor with an ultrathin uniform diaphragm.
Wang, Wenhui; Wu, Nan; Tian, Ye; Niezrecki, Christopher; Wang, Xingwei
2010-04-26
This paper presents an all-silica miniature optical fiber pressure/acoustic sensor based on the Fabry-Perot (FP) interferometric principle. The endface of the etched optical fiber tip and silica thin diaphragm on it form the FP structure. The uniform and thin silica diaphragm was fabricated by etching away the silicon substrate from a commercial silicon wafer that has a thermal oxide layer. The thin film was directly thermally bonded to the endface of the optical fiber thus creating the Fabry-Perot cavity. Thin films with a thickness from 1microm to 3microm have been bonded successfully. The sensor shows good linearity and hysteresis during measurement. A sensor with 0.75 microm-thick diaphragm thinned by post silica etching was demonstrated to have a sensitivity of 11 nm/kPa. The new sensor has great potential to be used as a non-intrusive pressure sensor in a variety of sensing applications.
Zhang, Zhihua; Yang, Xiaolu; Jin, Huiyi; Qu, Yuan; Zhang, Yuan; Liu, Kun; Xu, Xun
2016-12-06
Conbercept is a recombinant fusion protein with high affinity for all vascular endothelial growth factor isoforms and placental growth factor. The repeated intravitreal injection of conbercept may cause intraocular pressure (IOP) fluctuations and long-term suppression of neurotrophic cytokines, which could lead to retinal nerve fiber layer (RNFL) damage. This retrospective fellow-eye controlled study included 98 eyes of 49 patients. The changes in IOP and RNFL thickness as well as the correlation between RNFL changes and associated factors were evaluated. The IOP value between the baseline and the last follow-up visit in the injection group and the IOP value of the last follow-up visit between the injection and non-injection groups were not significantly different (p = 0.452 and 0.476, respectively). The global average thickness of the RNFL (μm) in the injection group decreased from 108.9 to 106.1; however, the change was not statistically significant (p = 0.118). No significant difference in the average RNFL thickness was observed at the last follow-up visit between the injection and non-injection groups (p = 0.821). The type of disease was the only factor associated with RNFL thickness changes. In conclusion, repeated intravitreal injections with 0.05 mL conbercept revealed an excellent safety profile for RNFL thickness, although short-term IOP changes were observed.
Gulmez Sevim, Duygu; Unlu, Metin; Gultekin, Murat; Karaca, Cagatay
2018-02-12
There have been ongoing clinical trials of therapeutic agents in Huntington's disease (HD) which requires development of reliable biomarkers of disease progression. There have been studies in the literature with conflicting results on the involvement of retina in HD, and up to date there is not a study evaluating the single retinal layers in HD. We aimed to evaluate the specific retinal changes in HD and their usability as potential disease progression markers. This cross-sectional study used spectral-domain optical coherence tomography with automatic segmentation to measure peripapillary retinal nerve fiber layer (pRNFL) thickness and the thickness and volume of retinal layers in foveal scans of 15 patients with HD and 15 age- and sex-matched controls. Genetic testing results, disease duration, HD disease burden scores and Unified HD Rating Scales motor scores were acquired for the patients. Temporal pRNFL, macular RNFL (mRNFL), ganglion cell layer (GCL), inner plexiform layer (IPL), inner nuclear layer and outer plexiform layer thicknesses and IPL, retinal pigment epithelium and outer macular volume were found lower in HD compared to controls, while outer nuclear layer and outer retinal layer thickness were increased (p < 0.05). We found significant correlations between inner retinal layer thicknesses, most significantly with mRNFL and GCL and disease progression markers. The outcomes of this study points out that retinal layers, most significantly mRNFL and GCL, are strongly correlated with the disease progression in HD and could serve as useful biomarkers for disease progression.
Spectral domain polarization-sensitive optical coherence tomography at 850 nm
NASA Astrophysics Data System (ADS)
Cense, Barry; Chen, Teresa C.; Mujat, Mircea; Joo, Chulmin; Akkin, Taner; Park, B. H.; Pierce, Mark C.; Yun, Andy; Bouma, Brett E.; Tearney, Guillermo J.; de Boer, Johannes F.
2005-04-01
Spectral-Domain Polarization-Sensitive Optical Coherence Tomography (SD-PS-OCT) is a technique developed to measure the thickness and birefringence of the nerve fiber layer in vivo as a tool for the early diagnosis of glaucoma. A clinical SD-PS-OCT system was developed and scans were made around the optic nerve head (ONH) using ten concentric circles of increasing diameter. One healthy volunteer was imaged. Retinal nerve fiber layer thickness and birefringence information was extracted from the data. Polarization-sensitive OCT images were acquired at video rate (29 frames per second (fps), 1000 A-lines / frame) and at 7 fps (1000 A-lines / frame). The last setting improved the signal to noise ratio by approximately 6 dB. Birefringence measurements on the healthy volunteer gave similar results as earlier reported values that were obtained with a time-domain setup. The measurement time was reduced from more than a minute to less than a second.
Faria, Mun Yueh; Ferreira, Nuno P; Cristóvao, Diana M; Mano, Sofia; Sousa, David Cordeiro; Monteiro-Grillo, Manuel
2018-01-01
To highlight tomographic structural changes of retinal layers after internal limiting membrane (ILM) peeling in macular hole surgery. Nonrandomized prospective, interventional study in 38 eyes (34 patients) subjected to pars plana vitrectomy and ILM peeling for idiopathic macular hole. Retinal layers were assessed in nasal and temporal regions before and 6 months after surgery using spectral domain optical coherence tomography. Total retinal thickness increased in the nasal region and decreased in the temporal region. The retinal nerve fiber layer (RNFL), ganglion cell layer (GCL), and inner plexiform layer (IPL) showed thinning on both nasal and temporal sides of the fovea. The thickness of the outer plexiform layer (OPL) increased. The outer nuclear layer (ONL) and outer retinal layers (ORL) increased in thickness after surgery in both nasal and temporal regions. ILM peeling is associated with important alterations in the inner retinal layer architecture, with thinning of the RNFL-GCL-IPL complex and thickening of OPL, ONL, and ORL. These structural alterations can help explain functional outcome and could give indications regarding the extent of ILM peeling, even though peeling seems important for higher rate of hole closure. © 2017 S. Karger AG, Basel.
Surface crack analysis applied to impact damage in a thick graphite-epoxy composite
NASA Technical Reports Server (NTRS)
Poe, C. C., Jr.; Harris, C. E.; Morris, D. H.
1988-01-01
The residual tensile strength of a thick graphite/epoxy composite with impact damage was predicted using surface crack analysis. The damage was localized to a region directly beneath the impact site and extended only part way through the laminate. The damaged region contained broken fibers, and the locus of breaks in each layer resembled a crack perpendicular to the direction of the fibers. In some cases, the impacts broke fibers without making a visible crater. The impact damage was represented as a semi-elliptical surface crack with length and depth equal to that of the impact damage. The maximum length and depth of the damage were predicted with a stress analysis and a maximum shear stress criterion. The predictions and measurements of strength were in good agreement.
Surface crack analysis applied to impact damage in a thick graphite/epoxy composite
NASA Technical Reports Server (NTRS)
Poe, Clarence C., Jr.; Harris, Charles E.; Morris, Don H.
1990-01-01
The residual tensile strength of a thick graphite/epoxy composite with impact damage was predicted using surface crack analysis. The damage was localized to a region directly beneath the impact site and extended only part way through the laminate. The damaged region contained broken fibers, and the locus of breaks in each layer resembled a crack perpendicular to the direction of the fibers. In some cases, the impacts broke fibers without making a visible crater. The impact damage was represented as a semi-elliptical surface crack with length and depth equal to that of the impact damage. The maximum length and depth of the damage were predicted with a stress analysis and a maximum shear stress criterion. The predictions and measurements of strength were in good agreement.
Faria, Mun Y; Ferreira, Nuno P; Mano, Sofia; Cristóvao, Diana M; Sousa, David C; Monteiro-Grillo, Manuel E
2018-05-01
To provide a spectral-domain optical coherence tomography (SD-OCT)-based analysis of retinal layers thickness and nasal displacement of closed macular hole after internal limiting membrane peeling in macular hole surgery. In this nonrandomized prospective interventional study, 36 eyes of 32 patients were subjected to pars plana vitrectomy and 3.5 mm diameter internal limiting membrane (ILM) peeling for idiopathic macular hole (IMH). Nasal and temporal internal retinal layer thickness were assessed with SD-OCT. Each scan included optic disc border so that distance between optic disc border and fovea were measured. Thirty-six eyes had a successful surgery with macular hole closure. Total nasal retinal thickening (p<0.001) and total temporal retinal thinning (p<0.0001) were observed. Outer retinal layers increased thickness after surgery (nasal p<0.05 and temporal p<0.01). Middle part of inner retinal layers (mIRL) had nasal thickening (p<0.001) and temporal thinning (p<0.05). The mIRL was obtained by deducting ganglion cell layer (GCL) and retinal nerve fiber layer (RNFL) thickness from overall thickness of the inner retinal layer. Papillofoveal distance was shorter after ILM peeling in macular hole surgery (3,651 ± 323 μm preoperatively and 3,361 ± 279 μm at 6 months; p<0.0001). Internal limiting membrane peel is associated with important alteration in inner retinal layer architecture, with thickening of mIRL and shortening of papillofoveal distance. These factors may contribute to recovery of disrupted foveal photoreceptor and vision improvement after IMH closure.
Wasyluk, Jaromir T.; Jankowska-Lech, Irmina; Terelak-Borys, Barbara; Grabska-Liberek, Iwona
2012-01-01
Summary Background We compared the parameters of retinal nerve fibre layer in patients with advanced glaucoma with the use of different OCT (Optical Coherence Tomograph) devices in relation to analogical measurements performed with GDx VCC (Nerve Fiber Analyzer with Variable Corneal Compensation) scanning laser polarimetry. Material/Methods Study subjects had advanced primary open-angle glaucoma, previously treated conservatively, diagnosed and confirmed by additional examinations (visual field, ophthalmoscopy of optic nerve, gonioscopy), A total of 10 patients were enrolled (9 women and 1 man), aged 18–70 years of age. Nineteen eyes with advanced glaucomatous neuropathy were examined. 1) Performing a threshold perimetry Octopus, G2 strategy and ophthalmoscopy of optic nerve to confirm the presence of advanced primary open-angle glaucoma; 2) performing a GDx VCC scanning laser polarimetry of retinal nerve fibre layer; 3) measuring the retinal nerve fibre layer thickness with 3 different optical coherence tomographs. Results The parameters of the retinal nerve fibre layer thickness are highly correlated between the GDx and OCT Stratus and 3D OCT-1000 devices in mean retinal nerve fibre layer thickness, retinal nerve fibre layer thickness in the upper sector, and correlation of NFI (GDx) with mean retinal nerve fibre layer thickness in OCT examinations. Absolute values of the retinal nerve fibre layer thickness (measured in μm) differ significantly between GDx and all OCT devices. Conclusions Examination with OCT devices is a sensitive diagnostic method of glaucoma, with good correlation with the results of GDx scanning laser polarimetry of the patients. PMID:22367131
NASA Astrophysics Data System (ADS)
Korposh, Sergiy; Kodaira, Suguru; Selyanchyn, Roman; Ledezma, Francisco H.; James, Stephen W.; Lee, Seung-Woo
2018-05-01
Highly sensitive fiber-optic ammonia gas sensors were fabricated via layer-by-layer deposition of poly(diallyldimethylammonium chloride) (PDDA) and tetrakis(4-sulfophenyl)porphine (TSPP) onto the surface of the core of a hard-clad multimode fiber that was stripped of its polymer cladding. The effects of film thickness, length of sensing area, and depth of evanescent wave penetration were investigated to clearly understand the sensor performance. The sensitivity of the fiber-optic sensor to ammonia was linear in the concentration range of 0.5-50 ppm and the response and recovery times were less than 3 min, with a limit of detection of 0.5 ppm, when a ten-cycle PDDA/TSPP film was assembled on the surface of the core along a 1 cm-long stripped section of the fiber. The sensor's response towards ammonia was also checked under different relative humidity conditions and a simple statistical data treatment approach, principal component analysis, demonstrated the feasibility of ammonia sensing in environmental relative humidity ranging from dry 7% to highly saturated 80%. Penetration depths of the evanescent wave for the optimal sensor configuration were estimated to be 30 and 33 nm at wavelengths of 420 and 706 nm, which are in a good agreement with the thickness of the 10-cycle deposited film (ca. 30 nm).
Simulated impact damage in a thick graphite/epoxy laminate using spherical indenters
NASA Technical Reports Server (NTRS)
Poe, C. C., Jr.
1988-01-01
A study was made to determine the extent of fiber damage caused by low-velocity impact of spherical impactors to a very thick graphite/epoxy laminate. The laminate was cut from a filament wound case being developed for the Space Shuttle solid rocket motors. The case was wound using a wet process with AS4W graphite fiber and HBRF-55A epoxy. Impacts were simulated under quasi-static conditions by pressing hemispherically shaped indenters against the laminate at different locations. The contact force and indenter diameter were varied from location to location. The forces were chosen for each indenter diameter to produce contact pressures below and above that required to initiate damage. After the forces were applied, the laminate was cut into smaller pieces so that each piece contained a test site. The pieces were then deplied and the individual plies examined to determine the extent of fiber damage. Broken fibers were found in the outer layers directly beneath the contact site. The locus of broken fibers in each layer resembled a crack normal to the direction of the fibers. The maximum length and depth of the cracks increased with increasing contact pressure and indenter diameter. The internal stresses in the laminate were calculated using Hertz's law and Love's solution for pressure applied on part of the boundary of a semi-infinite body. The maximum length and depth of the cracks were predicted using a maximum shear stress criterion. Predictions and measurements were in good agreement.
Photonic bandgap narrowing in conical hollow core Bragg fibers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ozturk, Fahri Emre; Yildirim, Adem; Kanik, Mehmet
2014-08-18
We report the photonic bandgap engineering of Bragg fibers by controlling the thickness profile of the fiber during the thermal drawing. Conical hollow core Bragg fibers were produced by thermal drawing under a rapidly alternating load, which was applied by introducing steep changes to the fiber drawing speed. In conventional cylindrical Bragg fibers, light is guided by omnidirectional reflections from interior dielectric mirrors with a single quarter wave stack period. In conical fibers, the diameter reduction introduced a gradient of the quarter wave stack period along the length of the fiber. Therefore, the light guided within the fiber encountered slightlymore » smaller dielectric layer thicknesses at each reflection, resulting in a progressive blueshift of the reflectance spectrum. As the reflectance spectrum shifts, longer wavelengths of the initial bandgap cease to be omnidirectionally reflected and exit through the cladding, which narrows the photonic bandgap. A narrow transmission bandwidth is particularly desirable in hollow waveguide mid-infrared sensing schemes, where broadband light is coupled to the fiber and the analyte vapor is introduced into the hollow core to measure infrared absorption. We carried out sensing simulations using the absorption spectrum of isopropyl alcohol vapor to demonstrate the importance of narrow bandgap fibers in chemical sensing applications.« less
Alasil, Tarek; Wang, Kaidi; Yu, Fei; Field, Matthew G.; Lee, Hang; Baniasadi, Neda; de Boer, Johannes F.; Coleman, Anne L.; Chen, Teresa C.
2015-01-01
Purpose To determine the retinal nerve fiber layer (RNFL) thickness at which visual field (VF) damage becomes detectable and associated with structural loss. Design Retrospective cross-sectional study. Methods Eighty seven healthy and 108 glaucoma subjects (one eye per subject) were recruited from an academic institution. All patients had VF examinations (Swedish Interactive Threshold Algorithm 24-2 test of the Humphrey visual field analyzer 750i; Carl Zeiss Meditec, Dublin, CA) and spectral domain optical coherence tomography RNFL scans (Spectralis, Heidelberg Engineering, Heidelberg, Germany). Comparison of RNFL thicknesses values with VF threshold values showed a plateau of VF threshold values at high RNFL thickness values and then a sharp decrease at lower RNFL thickness values. A broken stick statistical analysis was utilized to estimate the tipping point at which RNFL thickness values are associated with VF defects. The slope for the association between structure and function was computed for data above and below the tipping point. Results The mean RNFL thickness value that was associated with initial VF loss was 89 μm. The superior RNFL thickness value that was associated with initial corresponding inferior VF loss was 100 μm. The inferior RNFL thickness value that was associated with initial corresponding superior VF loss was 73 μm. The differences between all the slopes above and below the aforementioned tipping points were statistically significant (p<0.001). Conclusions In open angle glaucoma, substantial RNFL thinning or structural loss appears to be necessary before functional visual field defects become detectable. PMID:24487047
Şahin, Muhammed; Şahin, Alparslan; Kılınç, Faruk; Yüksel, Harun; Özkurt, Zeynep Gürsel; Türkcü, Fatih Mehmet; Pekkolay, Zafer; Soylu, Hikmet; Çaça, İhsan
2017-06-01
Increased secretion of growth hormone and insulin-like growth factor-1 in acromegaly has various effects on multiple organs. However, the ocular effects of acromegaly have yet to be investigated in detail. The aim of the present study was to compare retina ganglion cell/inner plexiform layer (GCIPL) and peripapillary nerve fiber layer thickness (pRNFL) between patients with acromegaly and healthy control subjects using spectral domain optical coherence tomography (SD-OCT). This cross-sectional, comparative study included 18 patients with acromegaly and 20 control subjects. All participants underwent SD-OCT to measure pRNFL (in the seven peripapillary areas), GCIPL (in the nine ETDRS areas), and central macular thickness (CMT). Visual field (VF) examinations were performed using a Humphrey field analyzer in acromegalic patients. Measurements were compared between patients with acromegaly and control subjects. A total of 33 eyes of 18 patients with acromegaly and 40 eyes of 20 control subjects met the inclusion criteria of the present study. The overall calculated average pRNFL thickness was significantly lower in patients with acromegaly than in control subjects (P = 0.01), with pRNFL thickness significantly lower in the temporal superior and temporal inferior quadrants. Contrary to our expectations, pRNFL thickness in the nasal quadrant was similar between acromegalic and control subjects. The mean overall pRNFL thickness and superonasal, nasal, inferonasal, and inferotemporal quadrant pRNFL thicknesses were found to correlate with the mean deviation (MD) according to Spearman's correlation. However, other quadrants were not correlated with VF sensitivity. No significant difference in CMT values was observed (P = 0.6). GCIPL thickness was significantly lower in all quadrants of the inner and outer macula, except for central and inferior outer quadrants, in the acromegaly group than that in the control group (P < 0.05). GCIPL thicknesses of the inferior inner and outer macula quadrants were found to correlate with MD, whereas no correlation was observed between other quadrants and VF sensitivity. We demonstrated that GCIPL thickness decreased in patients with acromegaly compared with that in control subjects. However, the nasal quadrant pRNFL thickness was similar in acromegaly, in contrast to our expectations. SD-OCT may have utility in the assessment of the effects of acromegaly on retinal structures.
NASA Astrophysics Data System (ADS)
Ramalingam, Rajinikumar; Atrey, M. D.
2017-12-01
Use of Fiber Bragg Grating (FBG) sensor is very appealing for sensing low temperature and strain in superconducting magnets because of their miniature size and the possibility of accommodating many sensors in a single fiber. The main drawback is their low intrinsic thermal sensitivity at low temperatures below 120 K. Approaching cryogenic temperatures, temperature changes lower than a few degrees Kelvin cannot be resolved, since they do not cause an appreciable shift of the wavelength diffracted by a bare FBG sensor. To improve the thermal sensitivity and thermal inertia below 77 K, the Bare FBG (BFBG) sensor can be coated with high thermal expansion coefficient materials. In this work, different metal were considered for coating the FBG sensor. For theoretical investigation, a double layered circular thick wall tube model has been considered to study the effect on sensitivity due to the mechanical properties like Young’s modulus, Thermal expansion coefficient, Poisson’s ratio of selected materials at a various cryogenic temperatures. The primary and the secondary coating thickness for a dual layer metal coated FBG sensor have been determined from the above study. The sensor was then fabricated and tested at cryogenic temperature range from 4-300 K. The cryogenic temperature characteristics of the tested sensors are reported.
Mugdha, Kumari; Kaur, Apjit; Sinha, Neha; Saxena, Sandeep
2016-01-01
AIM To evaluate retinal nerve fiber layer (RNFL) thickness profile in patients of thyroid ophthalmopathy with no clinical signs of optic nerve dysfunction. METHODS A prospective, case-control, observational study conducted at a tertiary care centre. Inclusion criteria consisted of patients with eyelid retraction in association with any one of: biochemical thyroid dysfunction, exophthalmos, or extraocular muscle involvement; or thyroid dysfunction in association with either exophthalmos or extra-ocular muscle involvement; or a clinical activity score (CAS)>3/7. Two measurements of RNFL thickness were done for each eye, by Cirrus HD-optical coherence tomography 6mo apart. RESULTS Mean age of the sample was 38.75y (range 13-70y) with 18 males and 22 females. Average RNFL thickness at first visit was 92.06±12.44 µm, significantly lower than control group (101.28±6.64 µm) (P=0.0001). Thickness of inferior quadrant decreased from 118.2±21.27 µm to 115.0±22.27 µm after 6mo (P=0.02). There was no correlation between the change in CAS and RNFL thickness. CONCLUSION Decreased RNFL thickness is an important feature of thyroid orbitopathy, which is an inherent outcome of compressive optic neuropathy of any etiology. Subclinical RNFL damage continues in the absence of clinical activity of the disease. RNFL evaluation is essential in Grave's disease and active intervention may be warranted in the presence of significant damage. PMID:27990368
Hong, Samin; Kim, Chan Yun; Lee, Won Seok; Seong, Gong Je
2010-01-01
To assess the reproducibility of the new spectral domain Cirrus high-definition optical coherence tomography (HD-OCT; Carl Zeiss Meditec, Dublin, CA, USA) for analysis of peripapillary retinal nerve fiber layer (RNFL) thickness in healthy eyes. Thirty healthy Korean volunteers were enrolled. Three optic disc cube 200 x 200 Cirrus HD-OCT scans were taken on the same day in discontinuous sessions by the same operator without using the repeat scan function. The reproducibility of the calculated RNFL thickness and probability code were determined by the intraclass correlation coefficient (ICC), coefficient of variation (CV), test-retest variability, and Fleiss' generalized kappa (kappa). Thirty-six eyes were analyzed. For average RNFL thickness, the ICC was 0.970, CV was 2.38%, and test-retest variability was 4.5 microm. For all quadrants except the nasal, ICCs were 0.972 or higher and CVs were 4.26% or less. Overall test-retest variability ranged from 5.8 to 8.1 microm. The kappa value of probability codes for average RNFL thickness was 0.690. The kappa values of quadrants and clock-hour sectors were lower in the nasal areas than in other areas. The reproducibility of Cirrus HD-OCT to analyze peripapillary RNFL thickness in healthy eyes was excellent compared with the previous reports for time domain Stratus OCT. For the calculated RNFL thickness and probability code, variability was relatively higher in the nasal area, and more careful analyses are needed.
Kwon, Young-Nam; Kim, In-Chul
2013-11-01
Hydrothermal stability of a porous nickel-supported silica membrane was successfully improved by deposition of titania multilayers on colloidal silica particles embedded in the porous nickel fiber support. Porous nickel-supported silica membranes were prepared by means of a dipping-freezing-fast drying (DFF) method. The titania layers were deposited on colloidal silica particles by repeating hydrolysis and condensation reactions of titanium isopropoxide on the silica particle surfaces. The deposition of thin titania layers on the nickel-supported silica membrane was verified by various analytical tools. The water flux and the solute rejection of the porous Ni fiber-supported silica membranes did not change after titania layer deposition, indicating that thickness of titania layers deposited on silica surface is enough thin not to affect the membrane performance. Moreover, improvement of the hydrothermal stability in the titania-deposited silica membranes was confirmed by stability tests, indicating that thin titania layers deposited on silica surface played an important role as a diffusion barrier against 90 degrees C water into silica particles.
Thermographic inspection of external thermal insulation systems with mechanical fixing
NASA Astrophysics Data System (ADS)
Simões, Nuno; Simões, Inês; Serra, Catarina; Tadeu, António
2015-05-01
An External Thermal Insulation Composite System (ETICS) kit may include anchors to mechanically fix the insulation product onto the wall. Using this option increases safety when compared to a simple bonded solution, however, it is more expensive and needs higher labor resources. The insulation product is then coated with rendering, which applied to the insulation material without any air gap. The rendering comprises one or more layers of coats with an embedded reinforcement. The most common multi-coat rendering system presents a base coat applied directly to the insulation product with a glass fiber mesh as reinforcement, followed by a second base coat, before a very thin coat (key coat) that prepares the surface to receive the finishing and decorative coat. The thickness of the rendering system may vary between around 5 to 10 mm. The higher thicknesses may be associated with a reinforcement composed by two layers of glass fiber mesh. The main purpose of this work is to apply infrared thermography (IRT) techniques to 2 ETICS solution (single or double layer of glass fiber mesh) and evaluate its capability in the detection of anchors. The reliability of IRT was tested using an ETICS configuration of expanded cork boards and a rendering system with one or two layers of glass fiber mesh. An active thermography approach was performed in laboratory conditions, in transmission and reflection mode. In the reflection mode halogen lamps and air heater were employed as the thermal stimulus. Air heater was also the source used in the transmission mode tests. The resulting data was processed in both time and frequency domains. In this last approach, phase contrast images were generated and studied.
NASA Astrophysics Data System (ADS)
Khan, Zeeshan; Islam, Saeed; Shah, Rehan Ali; Khan, Muhammad Altaf; Bonyah, Ebenezer; Jan, Bilal; Khan, Aurangzeb
Modern optical fibers require a double-layer coating on the glass fiber in order to provide protection from signal attenuation and mechanical damage. The most important plastic resins used in wires and optical fibers are plastic polyvinyl chloride (PVC) and low and high density polyethylene (LDPE/HDPE), nylon and Polysulfone. One of the most important things which affect the final product after processing is the design of the coating die. In the present study, double-layer optical fiber coating is performed using melt polymer satisfying Oldroyd 8-constant fluid model in a pressure type die with the effect of magneto-hydrodynamic (MHD). Wet-on-wet coating process is applied for double-layer optical fiber coating. The coating process in the coating die is modeled as a simple two-layer Couette flow of two immiscible fluids in an annulus with an assigned pressure gradient. Based on the assumptions of fully developed laminar and MHD flow, the Oldroyd 8-constant model of non-Newtonian fluid of two immiscible resin layers is modeled. The governing nonlinear equations are solved analytically by the new technique of Optimal Homotopy Asymptotic Method (OHAM). The convergence of the series solution is established. The results are also verified by the Adomian Decomposition Method (ADM). The effect of important parameters such as magnetic parameter Mi , the dilatant constant α , the Pseodoplastic constant β , the radii ratio δ , the pressure gradient Ω , the speed of fiber optics V , and the viscosity ratio κ on the velocity profiles, thickness of coated fiber optics, volume flow rate, and shear stress on the fiber optics are investigated. At the end the result of the present work is also compared with the experimental results already available in the literature by taking non-Newtonian parameters tends to zero.
Kim, Eun Kyoung; Park, Hae-Young Lopilly; Park, Chan Kee
2017-01-01
To evaluate the changes of retinal nerve fiber layer (RNFL), ganglion cell layer (GCL), inner plexiform layer (IPL), and ganglion cell-inner plexiform layer (GCIPL) thicknesses and compare structure-function relationships of 4 retinal layers using spectral-domain optical coherence tomography (SD-OCT) in macular region of glaucoma patients. In cross-sectional study, a total of 85 eyes with pre-perimetric to advanced glaucoma and 26 normal controls were enrolled. The glaucomatous eyes were subdivided into three groups according to the severity of visual field defect: a preperimetric glaucoma group, an early glaucoma group, and a moderate to advanced glaucoma group. RNFL, GCL, IPL, and GCIPL thicknesses were measured at the level of the macula by the Spectralis (Heidelberg Engineering, Heidelberg, Germany) SD-OCT with automated segmentation software. For functional evaluation, corresponding mean sensitivity (MS) values were measured using 24-2 standard automated perimetry (SAP). RNFL, GCL, IPL, and GCIPL thicknesses were significantly different among 4 groups (P < .001). Macular structure losses were positively correlated with the MS values of the 24-2 SAP for RNFL, GCL, IPL, and GCIPL (R = 0.553, 0.636, 0.648 and 0.646, respectively, P < .001). In regression analysis, IPL and GCIPL thicknesses showed stronger association with the corresponding MS values of 24-2 SAP compared with RNFL and GCL thicknesses (R2 = 0.420, P < .001 for IPL; R2 = 0.417, P< .001 for GCIPL thickness). Segmented IPL thickness was significantly associated with the degree of glaucoma. Segmental analysis of the inner retinal layer including the IPL in macular region may provide valuable information for evaluating glaucoma.
Conductive paper fabricated by layer-by-layer assembly of polyelectrolytes and ITO nanoparticles
NASA Astrophysics Data System (ADS)
Peng, C. Q.; Thio, Y. S.; Gerhardt, R. A.
2008-12-01
A new salt-free approach was developed for fabricating conductive paper by layer-by-layer (LBL) assembly of conductive indium tin oxide (ITO) nanoparticles and polyelectrolytes onto wood fibers. Subsequent to the coating procedure, the fibers were manufactured into conductive paper using traditional paper making methods. The wood fibers were first coated with polyethyleneimine (PEI) and then LBL assembled with poly(sodium 4-styrenesulfonate) (PSS) and ITO for several bilayers. The surface charge intensity of both the ITO nanoparticles and the coated wood fibers were evaluated by measuring the ζ-potential of the nanoparticles and short fibers, respectively. The ITO nanoparticles were found to preferentially aggregate on defects on the fiber surfaces and formed interconnected paths, which led to the formation of conductive percolation paths throughout the whole paper. With ten bilayer coatings, the as-made paper was made DC conductive, and its σdc was measured to be 5.2 × 10-6 S cm-1 in the in-plane (IP) direction, while the conductivity was 1.9 × 10-8 S cm-1 in the through-the-thickness (TT) direction. The percolation phenomena in these LBL-assembled ITO-coated paper fibers was evaluated using scanning electron microscopy (SEM), current atomic force microscopy (I-AFM), and impedance measurements. The AC electrical properties are reported for frequencies ranging from 0.01 Hz to 1 MHz. A clear transition from insulating to conducting behavior is observed in the AC conductivity.
Dynamic characteristics of specialty composite structures with embedded damping layers
NASA Technical Reports Server (NTRS)
Saravanos, D. A.; Chamis, C. C.
1993-01-01
Damping mechanics for simulating the damped dynamic characteristics in specialty composite structures with compliant interlaminar damping layers are presented. Finite-element based mechanics incorporating a discrete layer (or layer-wise) laminate damping theory are utilized to represent general laminate configurations in terms of lay-up and fiber orientation angles, cross-sectional thickness, shape, and boundary conditions. Evaluations of the method with exact solutions and experimental data illustrate the accuracy of the method. Additional applications investigate the potential for significant damping enhancement in angle-ply composite laminates with cocured interlaminar damping layers.
Higashide, Tomomi; Ohkubo, Shinji; Hangai, Masanori; Ito, Yasuki; Shimada, Noriaki; Ohno-Matsui, Kyoko; Terasaki, Hiroko; Sugiyama, Kazuhisa; Chew, Paul; Li, Kenneth K W; Yoshimura, Nagahisa
2016-01-01
To identify the factors which significantly contribute to the thickness variabilities in macular retinal layers measured by optical coherence tomography with or without magnification correction of analytical areas in normal subjects. The thickness of retinal layers {retinal nerve fiber layer (RNFL), ganglion cell layer plus inner plexiform layer (GCLIPL), RNFL plus GCLIPL (ganglion cell complex, GCC), total retina, total retina minus GCC (outer retina)} were measured by macular scans (RS-3000, NIDEK) in 202 eyes of 202 normal Asian subjects aged 20 to 60 years. The analytical areas were defined by three concentric circles (1-, 3- and 6-mm nominal diameters) with or without magnification correction. For each layer thickness, a semipartial correlation (sr) was calculated for explanatory variables including age, gender, axial length, corneal curvature, and signal strength index. Outer retinal thickness was significantly thinner in females than in males (sr2, 0.07 to 0.13) regardless of analytical areas or magnification correction. Without magnification correction, axial length had a significant positive sr with RNFL (sr2, 0.12 to 0.33) and a negative sr with GCLIPL (sr2, 0.22 to 0.31), GCC (sr2, 0.03 to 0.17), total retina (sr2, 0.07 to 0.17) and outer retina (sr2, 0.16 to 0.29) in multiple analytical areas. The significant sr in RNFL, GCLIPL and GCC became mostly insignificant following magnification correction. The strong correlation between the thickness of inner retinal layers and axial length appeared to result from magnification effects. Outer retinal thickness may differ by gender and axial length independently of magnification correction.
Higashide, Tomomi; Ohkubo, Shinji; Hangai, Masanori; Ito, Yasuki; Shimada, Noriaki; Ohno-Matsui, Kyoko; Terasaki, Hiroko; Sugiyama, Kazuhisa; Chew, Paul; Li, Kenneth K. W.; Yoshimura, Nagahisa
2016-01-01
Purpose To identify the factors which significantly contribute to the thickness variabilities in macular retinal layers measured by optical coherence tomography with or without magnification correction of analytical areas in normal subjects. Methods The thickness of retinal layers {retinal nerve fiber layer (RNFL), ganglion cell layer plus inner plexiform layer (GCLIPL), RNFL plus GCLIPL (ganglion cell complex, GCC), total retina, total retina minus GCC (outer retina)} were measured by macular scans (RS-3000, NIDEK) in 202 eyes of 202 normal Asian subjects aged 20 to 60 years. The analytical areas were defined by three concentric circles (1-, 3- and 6-mm nominal diameters) with or without magnification correction. For each layer thickness, a semipartial correlation (sr) was calculated for explanatory variables including age, gender, axial length, corneal curvature, and signal strength index. Results Outer retinal thickness was significantly thinner in females than in males (sr2, 0.07 to 0.13) regardless of analytical areas or magnification correction. Without magnification correction, axial length had a significant positive sr with RNFL (sr2, 0.12 to 0.33) and a negative sr with GCLIPL (sr2, 0.22 to 0.31), GCC (sr2, 0.03 to 0.17), total retina (sr2, 0.07 to 0.17) and outer retina (sr2, 0.16 to 0.29) in multiple analytical areas. The significant sr in RNFL, GCLIPL and GCC became mostly insignificant following magnification correction. Conclusions The strong correlation between the thickness of inner retinal layers and axial length appeared to result from magnification effects. Outer retinal thickness may differ by gender and axial length independently of magnification correction. PMID:26814541
Sezgin Akcay, Betul Ilkay; Gunay, Betul Onal; Kardes, Esra; Unlu, Cihan; Ergin, Ahmet
2017-01-01
To assess the effect of low, moderate, and high myopia on the thickness of the retinal nerve fiber layer (RNFL) and Ganglion cell complex (GCC) measured by Spectral Domain Optical Coherence Tomography (SD-OCT) in non-glaucomatous subjects. The subjects were divided into three groups: low (n = 81, 35.6%), moderate (n = 79, 34.8%), and highly myopic eyes (n = 67, 29.5%). The RNFL thickness profile, including the average, superior, nasal, inferior, and temporal quadrant and each of the eight directional thicknesses, was measured. GCC parameters, including the average, superior, and inferior values, the focal loss volume (FLV), and the global loss volume (GLV), were measured. The correlation between the OCT measurements and the axial length was evaluated. The average, superior, inferior, and nasal RNFL thicknesses of low and moderate myopic eyes were found to be significantly higher than those of highly myopic eyes. The temporal RNFL thicknesses were not different among the three groups. The average, superior, and inferior ganglion cell complex values of low and moderate myopic eyes were significantly higher than those of highly myopic eyes. The FLV and GLV of low and moderate myopic eyes were significantly higher than those of highly myopic eyes (p = 0.001 for all). In the moderate and high myopia groups, the average RNFL thickness and GCC thickness were both negatively correlated with the axial length. Highly myopic subjects tend to have thinner RNFL and GCC thicknesses than subjects with low and moderate myopia.
Retinal nerve fiber layer thickness in normals measured by spectral domain OCT.
Bendschneider, Delia; Tornow, Ralf P; Horn, Folkert K; Laemmer, Robert; Roessler, Christopher W; Juenemann, Anselm G; Kruse, Friedrich E; Mardin, Christian Y
2010-09-01
To determine normal values for peripapillary retinal nerve fiber layer thickness (RNFL) measured by spectral domain Optical Coherence Tomography (SOCT) in healthy white adults and to examine the relationship of RNFL with age, gender, and clinical variables. The peripapillary RNFL of 170 healthy patients (96 males and 74 females, age 20 to 78 y) was imaged with a high-resolution SOCT (Spectralis HRA+OCT, Heidelberg Engineering) in an observational cross-sectional study. RNFL thickness was measured around the optic nerve head using 16 automatically averaged, consecutive circular B-scans with 3.4-mm diameter. The automatically segmented RNFL thickness was divided into 32 segments (11.25 degrees each). One randomly selected eye per subject entered the study. Mean RNFL thickness in the study population was 97.2 ± 9.7 μm. Mean RNFL thickness was significantly negatively correlated with age (r = -0.214, P = 0.005), mean RNFL decrease per decade was 1.90 μm. As age dependency was different in different segments, age-correction of RNFL values was made for all segments separately. Age-adjusted RNFL thickness showed a significant correlation with axial length (r = -0.391, P = 0.001) and with refractive error (r = 0.396, P<0.001), but not with disc size (r = 0.124). Normal RNFL results with SOCT are comparable to those reported with time-domain OCT. In accordance with the literature on other devices, RNFL thickness measured with SOCT was significantly correlated with age and axial length. For creating a normative database of SOCT RNFL values have to be age adjusted.
Nieves-Moreno, María; Martínez-de-la-Casa, José M; Bambo, María P; Morales-Fernández, Laura; Van Keer, Karel; Vandewalle, Evelien; Stalmans, Ingeborg; García-Feijoó, Julián
2018-02-01
This study examines the capacity to detect glaucoma of inner macular layer thickness measured by spectral-domain optical coherence tomography (SD-OCT) using a new normative database as the reference standard. Participants ( N = 148) were recruited from Leuven (Belgium) and Zaragoza (Spain): 74 patients with early/moderate glaucoma and 74 age-matched healthy controls. One eye was randomly selected for a macular scan using the Spectralis SD-OCT. The variables measured with the instrument's segmentation software were: macular nerve fiber layer (mRNFL), ganglion cell layer (GCL), and inner plexiform layer (IPL) volume and thickness along with circumpapillary RNFL thickness (cpRNFL). The new normative database of macular variables was used to define the cutoff of normality as the fifth percentile by age group. Sensitivity, specificity, and area under the receiver operating characteristic curve (AUROC) of each macular measurement and of cpRNFL were used to distinguish between patients and controls. Overall sensitivity and specificity to detect early-moderate glaucoma were 42.2% and 88.9% for mRNFL, 42.4% and 95.6% for GCL, 42.2% and 94.5% for IPL, and 53% and 94.6% for RNFL, respectively. The best macular variable to discriminate between the two groups of subjects was outer temporal GCL thickness as indicated by an AUROC of 0.903. This variable performed similarly to mean cpRNFL thickness (AUROC = 0.845; P = 0.29). Using our normative database as reference, the diagnostic power of inner macular layer thickness proved comparable to that of peripapillary RNFL thickness. Spectralis SD-OCT, cpRNFL thickness, and individual macular inner layer thicknesses show comparable diagnostic capacity for glaucoma and RNFL, GCL, and IPL thickness may be useful as an alternative diagnostic test when the measure of cpRNFL shows artifacts.
Solid Freeform Fabrication of Composite-Material Objects
NASA Technical Reports Server (NTRS)
Wang, C. Jeff; Yang, Jason; Jang, Bor Z.
2005-01-01
Composite solid freeform fabrication (C-SFF) or composite layer manufacturing (CLM) is an automated process in which an advanced composite material (a matrix reinforced with continuous fibers) is formed into a freestanding, possibly complex, three-dimensional object. In CLM, there is no need for molds, dies, or other expensive tooling, and there is usually no need for machining to ensure that the object is formed to the desired net size and shape. CLM is a variant of extrusion-type rapid prototyping, in which a model or prototype of a solid object is built up by controlled extrusion of a polymeric or other material through an orifice that is translated to form patterned layers. The second layer is deposited on top of the first layer, the third layer is deposited on top of the second layer, and so forth, until the stack of layers reaches the desired final thickness and shape. The elements of CLM include (1) preparing a matrix resin in a form in which it will solidify subsequently, (2) mixing the fibers and matrix material to form a continuous pre-impregnated tow (also called "towpreg"), and (3) dispensing the pre-impregnated tow from a nozzle onto a base while moving the nozzle to form the dispensed material into a patterned layer of controlled thickness. When the material deposited into a given layer has solidified, the material for the next layer is deposited and patterned similarly, and so forth, until the desired overall object has been built up as a stack of patterned layers. Preferably, the deposition apparatus is controlled by a computer-aided design (CAD) system. The basic CLM concept can be adapted to the fabrication of parts from a variety of matrix materials. It is conceivable that a CLM apparatus could be placed at a remote location on Earth or in outer space where (1) spare parts are expected to be needed but (2) it would be uneconomical or impractical to store a full inventory of spare parts. A wide variety of towpregs could be prepared and stored on spools until needed. Long-shelf-life towpreg materials suitable for such use could include thermoplastic-coated carbon fibers and metal-coated SiC fibers. When a spare part was needed, the part could be fabricated by CLM under control by a CAD data file; thus, the part could be built automatically, at the scene, within hours or minutes.
Tsikata, Edem; Lee, Ramon; Shieh, Eric; Simavli, Huseyin; Que, Christian J.; Guo, Rong; Khoueir, Ziad; de Boer, Johannes; Chen, Teresa C.
2016-01-01
Purpose To describe spectral-domain optical coherence tomography (OCT) methods for quantifying neuroretinal rim tissue in glaucoma and to compare these methods to the traditional retinal nerve fiber layer thickness diagnostic parameter. Methods Neuroretinal rim parameters derived from three-dimensional (3D) volume scans were compared with the two-dimensional (2D) Spectralis retinal nerve fiber layer (RNFL) thickness scans for diagnostic capability. This study analyzed one eye per patient of 104 glaucoma patients and 58 healthy subjects. The shortest distances between the cup surface and the OCT-based disc margin were automatically calculated to determine the thickness and area of the minimum distance band (MDB) neuroretinal rim parameter. Traditional 150-μm reference surface–based rim parameters (volume, area, and thickness) were also calculated. The diagnostic capabilities of these five parameters were compared with RNFL thickness using the area under the receiver operating characteristic (AUROC) curves. Results The MDB thickness had significantly higher diagnostic capability than the RNFL thickness in the nasal (0.913 vs. 0.818, P = 0.004) and temporal (0.922 vs. 0.858, P = 0.026) quadrants and the inferonasal (0.950 vs. 0.897, P = 0.011) and superonasal (0.933 vs. 0.868, P = 0.012) sectors. The MDB area and the three neuroretinal rim parameters based on the 150-μm reference surface had diagnostic capabilities similar to RNFL thickness. Conclusions The 3D MDB thickness had a high diagnostic capability for glaucoma and may be of significant clinical utility. It had higher diagnostic capability than the RNFL thickness in the nasal and temporal quadrants and the inferonasal and superonasal sectors. PMID:27768203
Influence of gelatinous fibers on the shrinkage of silver maple
Donals G. Arganbright; Dwight W. Bensend; Floyd G. Manwiller
1970-01-01
The degree of lean was found to have a significant influence on the logitudinal and transverse shrinkage of three soft maple trees. This may be accounted for by differences in the cell wall layer thickness and fibril angle.
Mechanical, Chemical and Microstructural Characterization of Monazite-Coated Silicon Carbide Fibers
NASA Technical Reports Server (NTRS)
Bansal, N. P.; Wheeler, D. R.; Chen, Y. L.
2000-01-01
Tensile strengths of as-received Hi-Nicalon and Sylramic fibers and those having monazite surface coatings, deposited by atmospheric pressure chemical vapor deposition, were measured at room temperature and the Weibull statistical parameters determined. The average tensile strengths of uncoated Hi-Nicalon and Sylramic fibers were 3.19 +/- 0.73 and 2.78 +/- 0.53 GPa with a Weibull modulus of 5.41 and 5.52, respectively. The monazite-coated Hi-Nicalon and Sylramic fibers showed strength loss of approx. 10 and 15 percent, respectively, compared with the as-received fibers. The elemental compositions of the fibers and the coatings were analyzed using scanning Auger microprobe and energy dispersive X-ray spectroscopy. The LaPO4 coating on Hi-Nicalon fibers was approximately stoichiometric and about 50 nm thick. The coating on the Sylramic fibers extended to a depth of about 100 to 150 nm. The coating may have been stoichiometric LaPO4 in the first 30 to 40 nm of the layer. However, the surface roughness of Sylramic fiber made this profile somewhat difficult to interpret. Microstructural analyses of the fibers and the coatings were done by scanning electron microscopy, transmission electron microscopy, and selected area electron diffraction. Hi-Nicalon fiber consists of fine beta-SiC nanocrystals ranging in size from 1 to 30 mn embedded in an amorphous matrix. Sylramic is a polycrystalline stoichiometric silicon carbide fiber consisting of submicron beta-SiC crystallites ranging from 100 to 300 nm. Small amount of TiB2 nanocrystallites (approx. 50 nm) are also present. The LaPO4 coating on Hi-Nicalon fibers consisted of a chain of peanut shape particles having monazite-(La) structure. The coating on Sylramic fibers consisted of two layers. The inner layer was a chain of peanut shape particles having monazite-(La) structure. The outer layer was comprised of much smaller particles with a microcrystalline structure.
Thickness related textural properties of retinal nerve fiber layer in color fundus images.
Odstrcilik, Jan; Kolar, Radim; Tornow, Ralf-Peter; Jan, Jiri; Budai, Attila; Mayer, Markus; Vodakova, Martina; Laemmer, Robert; Lamos, Martin; Kuna, Zdenek; Gazarek, Jiri; Kubena, Tomas; Cernosek, Pavel; Ronzhina, Marina
2014-09-01
Images of ocular fundus are routinely utilized in ophthalmology. Since an examination using fundus camera is relatively fast and cheap procedure, it can be used as a proper diagnostic tool for screening of retinal diseases such as the glaucoma. One of the glaucoma symptoms is progressive atrophy of the retinal nerve fiber layer (RNFL) resulting in variations of the RNFL thickness. Here, we introduce a novel approach to capture these variations using computer-aided analysis of the RNFL textural appearance in standard and easily available color fundus images. The proposed method uses the features based on Gaussian Markov random fields and local binary patterns, together with various regression models for prediction of the RNFL thickness. The approach allows description of the changes in RNFL texture, directly reflecting variations in the RNFL thickness. Evaluation of the method is carried out on 16 normal ("healthy") and 8 glaucomatous eyes. We achieved significant correlation (normals: ρ=0.72±0.14; p≪0.05, glaucomatous: ρ=0.58±0.10; p≪0.05) between values of the model predicted output and the RNFL thickness measured by optical coherence tomography, which is currently regarded as a standard glaucoma assessment device. The evaluation thus revealed good applicability of the proposed approach to measure possible RNFL thinning. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.
NASA Astrophysics Data System (ADS)
Kosiel, Kamil; Koba, Marcin; Masiewicz, Marcin; Śmietana, Mateusz
2018-06-01
The paper shows application of atomic layer deposition (ALD) technique as a tool for tailoring sensorial properties of lossy-mode-resonance (LMR)-based optical fiber sensors. Hafnium dioxide (HfO2), zirconium dioxide (ZrO2), and tantalum oxide (TaxOy), as high-refractive-index dielectrics that are particularly convenient for LMR-sensor fabrication, were deposited by low-temperature (100 °C) ALD ensuring safe conditions for thermally vulnerable fibers. Applicability of HfO2 and ZrO2 overlays, deposited with ALD-related atomic level thickness accuracy for fabrication of LMR-sensors with controlled sensorial properties was presented. Additionally, for the first time according to our best knowledge, the double-layer overlay composed of two different materials - silicon nitride (SixNy) and TaxOy - is presented for the LMR fiber sensors. The thin films of such overlay were deposited by two different techniques - PECVD (the SixNy) and ALD (the TaxOy). Such approach ensures fast overlay fabrication and at the same time facility for resonant wavelength tuning, yielding devices with satisfactory sensorial properties.
NASA Astrophysics Data System (ADS)
Rottler, Andreas; Harland, Malte; Bröll, Markus; Klingbeil, Matthias; Ehlermann, Jens; Mendach, Stefan
2013-12-01
We experimentally demonstrate that hybrid plasmon-photon modes exist in a silver-coated glass bottle resonator. The bottle resonator is realized in a glass fiber with a smoothly varying diameter, which is subsequently coated with a rhodamine 800-dye doped acryl-glass layer and a 30 nm thick silver layer. We show by means of photoluminescence experiments supported by electromagnetic simulations that the rhodamine 800 photoluminescence excites hybrid plasmon-photon modes in such a bottle resonator, which provide a plasmon-type field enhancement at the outer silver surface and exhibit quality factors as high as 1000.
Black synthetic quartz glass layer for optical fiber cross-talk reduction fabricated by VAD method
NASA Astrophysics Data System (ADS)
Kobayashi, Soichi; Fukuda, Kaoru; Onishi, Gen; Fujii, Yusuke
2016-09-01
In this report the new black-glass fiber-preform fabricated by the vapor-phase axial deposition (VAD) method to realize high-resolution optical bundle fibers is discussed with the Energy Dispersive X-ray (EDX) analysis and the transmittance spectrum measurement. The black glass consists of SiO2, GeO2, Bi2O3 and Al2O3. Firstly, the rod-shaped soot of SiO2 and GeO2 is prepared by blowing SiCl4 and GeCl4 into the oxyhydrogen burner. Then the soot is dipped into the solution of the Bi and Al compounds. After drying the soot with Bi and Al penetrated, the soot is consolidated into the glass preform by heating with the carbon heater at 1650 degrees Celsius. The diameter of the obtained preform is 10.5 mm and the black glass layer thickness is 2.6 mm located at the periphery. The Bi concentration distribution shows the content of several wt% in the black glass layer. The black glass preform is drawn into the black optical fiber being expected to make a clear image because of no light leaking from the neighboring optical fibers as compared to the conventional fiber endoscope.
Xue, Kang; Wang, Min; Chen, Junyi; Huang, Xin; Xu, Gezhi
2013-01-01
To measure the thickness of the retinal nerve fiber layer (RNFL) of patients with retinitis pigmentosa (RP) and that of normal controls by scanning laser polarimetry with enhanced corneal compensation (GDxECC) and RTVue-optical coherence tomography (OCT). Fifty-two eyes of 26 patients were included. All patients underwent complete ophthalmological examinations and testing with GDxECC. Twenty-eight of 52 eyes of RP patients underwent RTVue-OCT measurements. A group of 50 eyes of 25 normal subjects (controls) was also included. GDxECC measured RNFL thickness in the peripapillary area in all subjects as well as temporal-superior-nasal-inferior-temporal (TSNIT) parameters, including TSNIT means, superior and inferior region means, TSNIT standard deviation (SD), inter-eye symmetry and nerve fiber indicator (NFI). RTVue-OCT measured the mean, superior, inferior, temporal and nasal quadrant RNFL thickness. In RP patients and controls, TSNIT means by GDxECC were, respectively, 65.00 ± 7.35 and 55.32 ± 5.20. Mean superior quadrant thicknesses were 80.56 ± 10.93 and 69.54 ± 7.45. Mean inferior thicknesses were 80.58 ± 9.34 and 69.12 ± 7.78. SDs were 27.92 ± 5.21 and 28.23 ± 4.01. Inter-eye symmetries were 0.82 ± 0.17 and 0.87 ± 0.09. NFIs were 9.74 ± 8.73 and 16.81 ± 8.13. The differences between mean TSNIT, mean superior and mean inferior quadrant thicknesses and NFIs were statistically significant (p < 0.001). In RTVue-OCT measurements, the differences between mean, superior, inferior and temporal quadrant RNFL thicknesses were statistically significant (p = 0.0322, 0.0213, 0.0387, 0.0005). The RNFL measured by GDxECC was significantly thicker in RP patients than in controls. RNFL thickness measured by RTVue-OCT was significantly greater in RP patients than in controls in the superior, inferior and temporal regions. This contribution provides information on RNFL thickness and discusses the mechanism underlying this phenomenon. Copyright © 2012 S. Karger AG, Basel.
Lee, Won June; Na, Kyeong Ik; Kim, Young Kook; Jeoung, Jin Wook; Park, Ki Ho
2017-06-01
To evaluate the diagnostic ability of wide-field retinal nerve fiber layer (RNFL) maps with swept-source optical coherence tomography (SS-OCT) for detection of preperimetric (PPG) and early perimetric glaucoma (EG). One hundred eighty-four eyes, including 67 healthy eyes, 43 eyes with PPG, and 74 eyes with EG, were analyzed. Patients underwent a comprehensive ocular examination including red-free RNFL photography, visual field testing and wide-field SS-OCT scanning (DRI-OCT-1 Atlantis; Topcon, Tokyo, Japan). SS-OCT provides a wide-field RNFL thickness map and a SuperPixel map, which are composed of the RNFL deviation map of the peripapillary area and the deviation map of the composition of the ganglion cell layer with the inner plexiform layer and RNFL (GC-IPL+RNFL) in the macular area. The ability to discriminate PPG and EG from healthy eyes was assessed using sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) for all parameters and criteria provided by the wide-field SS-OCT scan. The wide-field RNFL thickness map using SS-OCT showed the highest sensitivity of PPG-diagnostic and EG-diagnostic performance compared with the other SS-OCT criteria based on the internal normative base (93.0 and 97.3%, respectively). Among the SS-OCT continuous parameters, the RFNL thickness of the 7 clock-hour, inferior and inferotemporal macular ganglion cell analyses showed the largest AUC of PPG-diagnostic and EG-diagnostic performance (AUC=0.809 to 0.865). The wide-field RNFL thickness map using SS-OCT performed well in distinguishing eyes with PPG and EG from healthy eyes. In the clinical setting, wide-field RNFL maps of SS-OCT can be useful tools for detection of early-stage glaucoma.
Ambiya, Vikas; Goud, Abhilash; Khodani, Mitali; Chhablani, Jay
2017-04-01
The aim of this study was to evaluate ganglion cell layer and nerve fiber layer thickness after Brilliant Blue G (BBG)-assisted internal limiting membrane (ILM) peeling for vitreomacular disorders. Retrospective analysis of spectral domain optical coherence tomography (SD-OCT) of 42 eyes of 42 patients, who underwent pars plana vitrectomy with BBG-assisted ILM peeling, was performed. Inclusion criteria were idiopathic macular hole, idiopathic vitreomacular traction, and idiopathic epiretinal membrane. Key exclusion criteria were vitreoretinal interface abnormalities secondary to any other diseases, follow-up period of less than 3 months, and any other associated retinal pathology. Average, minimum, and sectoral ganglion cell, and inner plexiform layers (GCIPL) and retinal nerve fiber layer (RNFL) parameters were collected. Changes in these parameters from baseline to 3- and 6-month visits after surgery were analyzed. At 3 months after surgery, we found a statistically significant reduction in the average GCIPL thickness (P = 0.031) and also in the superior sectors (P < 0.05) compared to the baseline values. A similar reduction was observed in the minimum RNFL thickness (P = 0.028) as well as in the superior sectoral RNFL thickness (P < 0.05). In 14 eyes with 6 months of follow-up, a similar statistically significant thinning of the GCIPL and RNFL was observed. However, the difference between the 3-month and 6-month values was not statistically significant (P = 0.679). BBG-assisted ILM peeling for vitreomacular interface disorders leads to thinning of the inner retina including GCIPL and RNFL. These structural changes should be correlated with retinal function tests to explore the pros and cons of this surgical step.
Civelekler, Mustafa; Halili, Ismail; Gundogan, Faith C; Sobaci, Gungor
2009-01-01
Purpose: To investigate the value of temporal retinal nerve fiber layer (RNFLtemporal) thickness in the prediction of malingering. Materials and Methods: This prospective, cross-sectional study was conducted on 33 military conscripts with optic disc temporal pallor (ODTP) and 33 age-and sex-matched healthy controls. Initial visual acuity (VAi) and visual acuity after simulation examination techniques (VAaset) were assessed. The subjects whose VAaset were two or more lines higher than VAi were determined as malingerers. Thickness of the peripapillary RNFL was determined with OCT (Stratus OCT™, Carl Zeiss Meditec, Inc.). RNFLtemporal thickness of the subjects were categorized into one of the 1+ to 4+ groups according to 50% confidence interval (CI), 25% CI and 5% CI values which were assessed in the control group. The VAs were converted to LogMAR-VAs for statistical comparisons. Results: A significant difference was found only in the temporal quadrant of RNFL thickness in subjects with ODTP (P=0.002). Mean LogMAR-VA increased significantly after SETs (P<0.001). Sensitivity, specificity, positive and negative predictive values of categorized RNFLtemporal thickness in diagnosing malingering were 84.6%, 75.0%, 68.8%, 88.2%, respectively. ROC curve showed that RNFLtemporal thickness of 67.5 μm is a significant cut-off point in determining malingering (P=0.001, area under the curve:0.862). The correlations between LogMAR-VAs and RNFLtemporal thicknesses were significant; the correlation coefficient for LogMAR-VAi was lower than the correlation for LogMAR-VAaset (r=−0.447, P=0.009 for LogMAR-VAi; r=−0.676, P<0.001 for LogMAR-VAaset). Conclusions: RNFLtemporal thickness assessment may be a valuable tool in determining malingering in subjects with ODTP objectively. PMID:19700875
Huang, David; Chopra, Vikas; Lu, Ake Tzu-Hui; Tan, Ou; Francis, Brian; Varma, Rohit
2012-01-01
Purpose. To determine the relationship between retinal nerve fiber layer (RNFL) thickness, optic disc size, and image magnification. Methods. The cohort consisted of 196 normal eyes of 101 participants in the Advanced Imaging for Glaucoma Study (AIGS), a multicenter, prospective, longitudinal study to develop advanced imaging technologies for glaucoma diagnosis. Scanning laser tomography was used to measure disc size. Optical coherence tomography (OCT) was used to perform circumpapillary RNFL thickness measurements using the standard fixed 3.46-mm nominal scan diameter. A theoretical model of magnification effects was developed to relate RNFL thickness (overall average) with axial length and magnification. Results. Multivariate regression showed no significant correlation between RNFL thickness and optic disc area (95% confidence interval [CI] = −0.9 to 4.1 μm/mm2, P = 0.21). Linear regression showed that RNFL thickness depended significantly on axial length (slope = −3.1 μm/mm, 95% CI = −4.9 to −1.3, P = 0.001) and age (slope = −0.3 μm/y, 95% CI = −0.5 to −0.2, P = 0.0002). The slope values agreed closely with the values predicted by the magnification model. Conclusions. There is no significant association between RNFL thickness and optic disc area. Previous publications that showed such an association may have been biased by the effect of axial length on fundus image magnification and, therefore, both measured RNFL thickness and apparent disc area. The true diameter of the circumpapillary OCT scan is larger for a longer eye (more myopic eye), leading to a thinner RNFL measurement. Adjustment of measured RNFL thickness by axial length, in addition to age, may lead to a tighter normative range and improve the detection of RNFL thinning due to glaucoma. PMID:22743319
Cingu, Abdullah Kursat; Cinar, Yasin; Turkcu, Fatih Mehmet; Sahinoglu-Keskek, Nedime; Sahin, Alparslan; Sahin, Muhammed; Yuksel, Harun; Caca, Ihsan
2014-09-01
The aim of this study was to evaluate the retinal nerve fiber layer (RNFL) thickness in vernal keratoconjunctivitis (VKC) patients who were under long-term topical corticosteroid therapy. Thirty-six eyes of 36 VKC patients with clear cornea and normal videokeratography and 40 eyes of 40 age- and gender-matched normal children were included in the study. Clinical and demographic characteristics of the patients were noted and detailed ophthalmological examination was performed. Visual acuity (VA), spherical equivalent (SE), axial length (AL) and RNFL thickness measurements were compared between the groups. To correct ocular magnification effect on RNFL, we used Littmann's formula. All VKC patients had history of topical corticosteroid use and the mean duration of the topical corticosteroid use was 23.8 ± 9.09 months. There was no significant difference between the groups in terms of intraocular pressure (IOP). VKC group had significantly worse VA, greater SE and AL and thinner mean global, superior and inferior RNFL thickness. There were significant negative correlations between the duration of topical corticosteroid use and the mean global, superior and temporal RNFL thickness in VKC group. After correction of magnification effect, VKC group still had thinner mean global, superior and inferior RNFL thickness, and significant difference between the groups in inferior RNFL thickness did not disappear. Significant RNFL thickness difference between the groups suggests a possible effect of long-term corticosteroid use in VKC patients. Because visual field (VF) analysis in pediatric patients is difficult to perform and IOP may be illusive, RNFL thickness measurements in addition to routine examinations in VKC patients may help clinicians in their practice.
NASA Astrophysics Data System (ADS)
Srividya, K.; Reddy, Ch. Kishore; Sumanth, Ch. Mohan; Krishnaiah, P. Gopala; Kishan, V. Mallikharjuna
2018-04-01
The present investigation deals with the free vibration analysis of a thick four-layered symmetric cross-ply skew laminated composite plate with a circular cutout. Three dimensional finite element models (FEM) which use the elasticity theory for the determination of stiffness matrices are modeled in ANSYS software to evaluate first five natural frequencies of the laminate. The variations of the first five natural frequencies with respect to length to thickness ratio (S) for different diameter to length ratios (d/l) are presented. It is observed that, the natural frequencies decreases with increase of thickness ratio(S).
Experimental Tests on the Composite Foam Sandwich Pipes Subjected to Axial Load
NASA Astrophysics Data System (ADS)
Li, Feng; Zhao, QiLin; Xu, Kang; Zhang, DongDong
2015-12-01
Compared to the composite thin-walled tube, the composite foam sandwich pipe has better local flexural rigidity, which can take full advantage of the high strength of composite materials. In this paper, a series of composite foam sandwich pipes with different parameters were designed and manufactured using the prefabricated polyurethane foam core-skin co-curing molding technique with E-glass fabric prepreg. The corresponding axial-load compressive tests were conducted to investigate the influence factors that experimentally determine the axial compressive performances of the tubes. In the tests, the detailed failure process and the corresponding load-displacement characteristics were obtained; the influence rules of the foam core density, surface layer thickness, fiber ply combination and end restraint on the failure modes and ultimate bearing capacity were studied. Results indicated that: (1) the fiber ply combination, surface layer thickness and end restraint have a great influence on the ultimate load bearing capacity; (2) a reasonable fiber ply combination and reliable interfacial adhesion not only optimize the strength but also transform the failure mode from brittle failure to ductile failure, which is vital to the fully utilization of the composite strength of these composite foam sandwich pipes.
Kucukevcilioglu, Murat; Ayyildiz, Onder; Aykas, Seckin; Gokce, Gokcen; Koylu, Mehmet Talay; Ozgonul, Cem; Ozge, Gokhan; Mumcuoglu, Tarkan; Yumusak, Erhan
2017-02-01
To investigate retinal nerve fiber layer thickness (RNFL-T) and peripapillary choroidal thickness (PC-T) in non-glaucomatous optic atrophy (OA) patients in comparison with unaffected and control eyes, furthermore, to compare thickness profiles with unilateral pseudoexfoliative advanced glaucoma. Thirty-three eyes with OA (Group A), 33 unaffected fellow eyes (Group B), 25 right eyes of 25 control subjects (Group C), and 15 eyes with advanced glaucoma (Group D) were enrolled. RNFL-T was measured in six regions by spectral-domain optical coherence tomography. Enhanced depth imaging optical coherence tomography was obtained to evaluate PC-T in corresponding regions. RNFL-T was significantly lower in Group A than in Groups B and C globally and at all peripapillary regions (all p < 0.001). P-CT in Group A was significantly lower globally (p = 0.03) and in three regions (temporal, p = 0.001; temporal-superior, p = 0.01; and nasal-inferior, p = 0.037) versus Group C. However, it was significantly thinner than in Group B in all regions (temporal, p = 0.02; temporal-superior, p = 0.013; nasal-superior, p = 0.044; nasal, p = 0.02; nasal-inferior, p < 0.001; and temporal-inferior, p < 0.001) and globally (p < 0.001). In Group A RNFL-T (thicker superiorly and inferiorly; thinner temporally and nasally) and PC-T (superior > temporal > nasal > inferior) profiles were almost identical to that in unaffected fellow eyes and control eyes. However, Group D showed different patterns with less regional differences in RNFL-T, and the greatest value of PC-T in nasal quadrant. Besides retinal nerve fiber layer thinning, non-glaucomatous OA is associated with choroidal thinning. The RNFL-T and PC-T profiles in advanced glaucoma eyes differed from the common patterns seen among OA eyes, unaffected fellow eyes, and control eyes.
Cellular migration to electrospun poly(lactic acid) fibermats.
Fujikura, Kie; Obata, Akiko; Kasuga, Toshihiro
2012-01-01
Nonwoven fabrics prepared via an electrospinning method, so-called electrospun fibermats, are expected to be promising scaffold materials for bone tissue engineering. In the present work, poly(L-lactic acid) (PLLA) fibermats, consisting of fibers with diameters ranging from 1 to 10 μm, were prepared by electrospinning. Mouse osteoblast-like cells (MC3T3-E1) were seeded on the fibermats with various fiber diameters (10, 5 and 2 μm; they are denoted by samples A, B and C, respectively) and cultured in two different directions in order to compare the migration behaviours into the scaffold of the normal condition and the anti-gravity condition. The cells in/on the fibermats were observed by laser confocal microscopy to estimate the cellular migration ability into them. When the MC3T3-E1 cells were cultured in the normal direction, the thickness of their layer increased to approx. 90 μm in the sample A, consisting of 10-μm fibers after 13 days of culture, while that in the sample C, consisting of 2-μm fibers, did not increase. When the MC3T3-E1 cells were cultured in the anti-gravity condition, the thickness of the cell layer in the sample A increased to approx. 60 μm. These results mean that the MC3T3-E1 cells migrated into the inside of sample A in either the normal direction or the anti-gravity one. The cellular proliferation showed no significant difference among the fibermats with three different fiber diameters; MC3T3-E1 cells on the fibermat with 2 μm fiber diameter grew two-dimensionally, while they grew three-dimensionally in the fibermat with 10 μm fiber diameter.
Takayama, Kohei; Ooto, Sotaro; Hangai, Masanori; Ueda-Arakawa, Naoko; Yoshida, Sachiko; Akagi, Tadamichi; Ikeda, Hanako Ohashi; Nonaka, Atsushi; Hanebuchi, Masaaki; Inoue, Takashi; Yoshimura, Nagahisa
2013-05-01
To detect pathologic changes in retinal nerve fiber bundles in glaucomatous eyes seen on images obtained by adaptive optics (AO) scanning laser ophthalmoscopy (AO SLO). Prospective cross-sectional study. Twenty-eight eyes of 28 patients with open-angle glaucoma and 21 normal eyes of 21 volunteer subjects underwent a full ophthalmologic examination, visual field testing using a Humphrey Field Analyzer, fundus photography, red-free SLO imaging, spectral-domain optical coherence tomography, and imaging with an original prototype AO SLO system. The AO SLO images showed many hyperreflective bundles suggesting nerve fiber bundles. In glaucomatous eyes, the nerve fiber bundles were narrower than in normal eyes, and the nerve fiber layer thickness was correlated with the nerve fiber bundle widths on AO SLO (P < .001). In the nerve fiber layer defect area on fundus photography, the nerve fiber bundles on AO SLO were narrower compared with those in normal eyes (P < .001). At 60 degrees on the inferior temporal side of the optic disc, the nerve fiber bundle width was significantly lower, even in areas without nerve fiber layer defect, in eyes with glaucomatous eyes compared with normal eyes (P = .026). The mean deviations of each cluster in visual field testing were correlated with the corresponding nerve fiber bundle widths (P = .017). AO SLO images showed reduced nerve fiber bundle widths both in clinically normal and abnormal areas of glaucomatous eyes, and these abnormalities were associated with visual field defects, suggesting that AO SLO may be useful for detecting early nerve fiber bundle abnormalities associated with loss of visual function. Copyright © 2013 Elsevier Inc. All rights reserved.
Cordeiro, Daniela Valença; Lima, Verônica Castro; Castro, Dinorah P; Castro, Leonardo C; Pacheco, Maria Angélica; Lee, Jae Min; Dimantas, Marcelo I; Prata, Tiago Santos
2011-01-01
To evaluate the influence of optic disc size on the diagnostic accuracy of macular ganglion cell complex (GCC) and conventional peripapillary retinal nerve fiber layer (pRNFL) analyses provided by spectral domain optical coherence tomography (SD-OCT) in glaucoma. Eighty-two glaucoma patients and 30 healthy subjects were included. All patients underwent GCC (7 × 7 mm macular grid, consisting of RNFL, ganglion cell and inner plexiform layers) and pRNFL thickness measurement (3.45 mm circular scan) by SD-OCT. One eye was randomly selected for analysis. Initially, receiver operating characteristic (ROC) curves were generated for different GCC and pRNFL parameters. The effect of disc area on the diagnostic accuracy of these parameters was evaluated using a logistic ROC regression model. Subsequently, 1.5, 2.0, and 2.5 mm(2) disc sizes were arbitrarily chosen (based on data distribution) and the predicted areas under the ROC curves (AUCs) and sensitivities were compared at fixed specificities for each. Average mean deviation index for glaucomatous eyes was -5.3 ± 5.2 dB. Similar AUCs were found for the best pRNFL (average thickness = 0.872) and GCC parameters (average thickness = 0.824; P = 0.19). The coefficient representing disc area in the ROC regression model was not statistically significant for average pRNFL thickness (-0.176) or average GCC thickness (0.088; P ≥ 0.56). AUCs for fixed disc areas (1.5, 2.0, and 2.5 mm(2)) were 0.904, 0.891, and 0.875 for average pRNFL thickness and 0.834, 0.842, and 0.851 for average GCC thickness, respectively. The highest sensitivities - at 80% specificity for average pRNFL (84.5%) and GCC thicknesses (74.5%) - were found with disc sizes fixed at 1.5 mm(2) and 2.5 mm(2). Diagnostic accuracy was similar between pRNFL and GCC thickness parameters. Although not statistically significant, there was a trend for a better diagnostic accuracy of pRNFL thickness measurement in cases of smaller discs. For GCC analysis, an inverse effect was observed.
Specific features of implosion of metallized fiber arrays
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mitrofanov, K. N., E-mail: mitrofan@triniti.ru; Aleksandrov, V. V.; Gritsuk, A. N.
2017-02-15
Implosion of metallized fiber arrays was studied experimentally at the Angara-5-1 facility. The use of such arrays makes it possible to investigate the production and implosion dynamics of plasmas of various metals (such as tin, indium, and bismuth) that were previously unavailable for such studies. The plasma production rates m-dot (in μg/(cm{sup 2} ns)) for different metals were determined and quantitatively compared. Varying the thickness of the metal layer deposited on kapron fibers (the total linear mass of the metal coating being maintained at the level of 220 μg/cm), the current and velocity of the plasma precursor were studied asmore » functions of the thickness of the metal coating. The strong difference in the rates of plasma production from the metal coating and kapron fibers results in the redistribution of the discharge current between the Z-pinch and the trailing fiber plasma. The outer boundary of the plasma produced from the metal coating is found to be stable against instabilities typical of the final stage of implosion of conventional wire arrays.« less
NASA Technical Reports Server (NTRS)
Arnold, Steven M.; Arya, Vinod K.; Melis, Matthew E.
1990-01-01
High residual stresses within intermetallic and metal matrix composite systems can develop upon cooling from the processing temperature to room temperature due to the coefficient of thermal expansion (CTE) mismatch between the fiber and matrix. As a result, within certain composite systems, radial, circumferential, and/or longitudinal cracks have been observed to form at the fiber-matrix interface. The compliant layer concept (insertion of a compensating interface material between the fiber and matrix) was proposed to reduce or eliminate the residual stress buildup during cooling and thus minimize cracking. The viability of the proposed compliant layer concept is investigated both elastically and elastoplastically. A detailed parametric study was conducted using a unit cell model consisting of three concentric cylinders to determine the required character (i.e., thickness and material properties) of the compliant layer as well as its applicability. The unknown compliant layer mechanical properties were expressed as ratios of the corresponding temperature dependent Ti-24Al-11Nb (a/o) matrix properties. The fiber properties taken were those corresponding to SCS-6 (SiC). Results indicate that the compliant layer can be used to reduce, if not eliminate, radial and circumferential residual stresses within the fiber and matrix and therefore also reduce or eliminate the radial cracking. However, with this decrease in in-plane stresses, one obtains an increase in longitudinal stress, thus potentially initiating longitudinal cracking. Guidelines are given for the selection of a specific compliant material, given a perfectly bonded system.
Shin, Hye-Young; Park, Hae-Young Lopilly; Jung, Kyoung-In; Choi, Jin-A; Park, Chan Kee
2014-01-01
To determine whether the ganglion cell-inner plexiform layer (GCIPL) or circumpapillary retinal nerve fiber layer (cpRNFL) is better at distinguishing eyes with early glaucoma from normal eyes on the basis of the the initial location of the visual field (VF) damage. Retrospective, observational study. Eighty-four patients with early glaucoma and 43 normal subjects were enrolled. The patients with glaucoma were subdivided into 2 groups according to the location of VF damage: (1) an isolated parafoveal scotoma (PFS, N = 42) within 12 points of a central 10 degrees in 1 hemifield or (2) an isolated peripheral nasal step (PNS, N = 42) within the nasal periphery outside 10 degrees of fixation in 1 hemifield. All patients underwent macular and optic disc scanning using Cirrus high-definition optical coherence tomography (Carl Zeiss Meditec, Dublin, CA). The GCIPL and cpRNFL thicknesses were compared between groups. Areas under the receiver operating characteristic curves (AUCs) were calculated. Comparison of diagnostic ability using AUCs. The average and minimum GCIPL of the PFS group were significantly thinner than those of the PNS group, whereas there was no significant difference in the average retinal nerve fiber layer (RNFL) thickness between the 2 groups. The AUCs of the average (0.962) and minimum GCIPL (0.973) thicknesses did not differ from that of the average RNFL thickness (0.972) for discriminating glaucomatous changes between normal and all glaucoma eyes (P =0.566 and 0.974, respectively). In the PFS group, the AUCs of the average (0.988) and minimum GCIPL (0.999) thicknesses were greater than that of the average RNFL thickness (0.961, P =0.307 and 0.125, respectively). However, the AUCs of the average (0.936) and minimum GCIPL (0.947) thicknesses were lower than that of the average RNFL thickness (0.984) in the PNS group (P =0.032 and 0.069, respectively). The GCIPL parameters were more valuable than the cpRNFL parameters for detecting glaucoma in eyes with parafoveal VF loss, and the cpRNFL parameters were better than the GCIPL parameters for detecting glaucoma in eyes with peripheral VF loss. Clinicians should know that the diagnostic capability of macular GCIPL parameters depends largely on the location of the VF loss. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Static Analysis of Functionally Graded Composite Beams
NASA Astrophysics Data System (ADS)
Das, S.; Sarangi, S. K.
2016-09-01
This paper presents a study of functionally graded (FG) composite beam. The FG material for the beam is considered to be composed of different layers of homogeneous material. The fiber volume fraction corresponding to each layer is calculated by considering its variation along the thickness direction (z) according to a power law. Accordingly, the effective properties of the homogeneous layers are estimated and a beam composed of this FG material is modelled using the commercially available ANSYS software. The solid 186 layered structural solid element has been used for discretization of the model of the FG beam. The model developed is validated by comparing the results with those numerical results available in literature. Results are presented for simply supported and fixed boundary conditions for the FG beam. The stress distribution across the thickness of the FG composite beam has also been analyzed.
Hammel, Naama; Belghith, Akram; Weinreb, Robert N; Medeiros, Felipe A; Mendoza, Nadia; Zangwill, Linda M
2017-06-01
To compare the rates of circumpapillary retinal nerve fiber layer (RNFL) and macular retinal ganglion cell-inner plexiform layer (GCIPL) change over time in healthy and glaucoma eyes. Cohort study. The rates of circumpapillary RNFL and macular GCIPL loss in 28 healthy subjects and 97 glaucoma subjects from the Diagnostic Innovations in Glaucoma Study (DIGS) were compared using mixed-effects models. The median follow-up time and number of visits were 1.7 years and 6 visits and 3.2 years and 7 visits for healthy and glaucoma eyes, respectively. Significant rates of loss of both global circumpapillary RNFL and average macular GCIPL thickness were detectable in early and moderate glaucoma eyes; in severe glaucoma eyes, rates of average macular GCIPL loss were significant, but rates of global circumpapillary RNFL loss were not. In glaucoma eyes, mean rates of global circumpapillary RNFL thickness change (-0.98 μm/year [95% confidence interval (CI), -1.20 to -0.76]) and normalized global circumpapillary RNFL change (-1.7%/year [95% CI, -2.1 to -1.3]) were significantly faster than average macular GCIPL change (-0.57 μm/year [(95% CI, -0.73 to -0.41]) and normalized macular GCIPL change (-1.3%/year [95% CI, -1.7 to -0.9]). The rates of global and inferior RNFL change were weakly correlated with global and inferior macular GCIPL change (r ranges from 0.16 to 0.23, all P < .05). In this cohort, the rate of circumpapillary RNFL thickness change was faster than macular GCIPL change for glaucoma eyes. Global circumpapillary RNFL thickness loss was detectable in early and moderate glaucoma, and average macular GCIPL thickness loss was detectable in early, moderate, and severe glaucoma, suggesting that structural changes can be detected in severe glaucoma. Copyright © 2017 Elsevier Inc. All rights reserved.
Infrared imaging of the polymer 3D-printing process
NASA Astrophysics Data System (ADS)
Dinwiddie, Ralph B.; Kunc, Vlastimil; Lindal, John M.; Post, Brian; Smith, Rachel J.; Love, Lonnie; Duty, Chad E.
2014-05-01
Both mid-wave and long-wave IR cameras are used to measure various temperature profiles in thermoplastic parts as they are printed. Two significantly different 3D-printers are used in this study. The first is a small scale commercially available Solidoodle 3 printer, which prints parts with layer thicknesses on the order of 125μm. The second printer used is a "Big Area Additive Manufacturing" (BAAM) 3D-printer developed at Oak Ridge National Laboratory. The BAAM prints parts with a layer thicknesses of 4.06 mm. Of particular interest is the temperature of the previously deposited layer as the new hot layer is about to be extruded onto it. The two layers are expected have a stronger bond if the temperature of the substrate layer is above the glass transition temperature. This paper describes the measurement technique and results for a study of temperature decay and substrate layer temperature for ABS thermoplastic with and without the addition of chopped carbon fibers.
Alnawaiseh, Maged; Hömberg, Lisann; Eter, Nicole; Prokosch, Verena
2017-01-01
To compare the structure-function relationships between retinal nerve fiber layer thickness (RNFLT) and visual field defects measured either by standard automated perimetry (SAP) or by Pulsar perimetry (PP). 263 eyes of 143 patients were prospectively included. Depending on the RNFLT, patients were assigned to the glaucoma group (group A: RNFL score 3-6) or the control group (group B: RNFL score 0-2). Structure-function relationships between RNFLT and mean sensitivity (MS) measured by SAP and PP were analyzed. Throughout the entire group, the MS assessed by PP and SAP correlated significantly with RNFLT in all sectors. In the glaucoma group, there was no significant difference between the correlations RNFL-SAP and RNFL-PP, whereas a significant difference was found in the control group. In the control group, the correlation between structure and function based on the PP data was significantly stronger than that based on SAP.
Yang, Liu; Qu, Yuanzhen; Lu, Wen; Liu, Fengjun
2016-07-03
BACKGROUND The aim of this study was to compare the differences in macular ganglion cell complex (GCC) and peripapillary retinal nerve fiber layer (pRNFL) in child and adult patients with primary craniopharyngioma by Fourier-domain optical coherence tomography (FD-OCT) and to evaluate their significance in the diagnosis of primary craniopharyngioma. MATERIAL AND METHODS Ninety-six participants were divided into 3 groups: 32 in the child craniopharyngioma group (CCG) and 32 in the adult craniopharyngioma group (ACG) who were treated in Beijing Tiantan Hospital between November 2013 and October 2014, and 32 in the normal group (NG). All subjects were scanned by FD-OCT to map GCC and pRNFL thicknesses. Spearman correlation coefficient was used to assess the correlation between GCC and pRNFL thickness, and pRNFL thickness and optic nerve head (ONH) parameters, including horizontal cup-disc ratio (HCDR), vertical cup-disc ratio (VCDR), optic disc area (ODA), and cup area (CA), respectively. RESULTS The correlation between GCC and pRNFL thickness in the CCG was slightly stronger compared with the ACG. A significant difference in GCC thickness was observed among the CCG, ACG, and NG. Although the pRNFL thickness in both the CCG and ACG was significantly higher than that in NG, no significant difference in pRNFL thickness was detected between the 2 craniopharyngioma groups. The average, superior, and inferior pRNFL thicknesses were negatively correlated with VCDR in the CCG (in double eyes) and ACG (only in left eyes). CONCLUSIONS GCC was more sensitive than pRNFL in detecting optic nerve damage in the eyes of craniopharyngioma patients. A thinner pRNFL was especially correlated with VCDR in child craniopharyngioma patients.
Yang, Liu; Qu, Yuanzhen; Lu, Wen; Liu, Fengjun
2016-01-01
Background The aim of this study was to compare the differences in macular ganglion cell complex (GCC) and peripapillary retinal nerve fiber layer (pRNFL) in child and adult patients with primary craniopharyngioma by Fourier-domain optical coherence tomography (FD-OCT) and to evaluate their significance in the diagnosis of primary craniopharyngioma. Material/Methods Ninety-six participants were divided into 3 groups: 32 in the child craniopharyngioma group (CCG) and 32 in the adult craniopharyngioma group (ACG) who were treated in Beijing Tiantan Hospital between November 2013 and October 2014, and 32 in the normal group (NG). All subjects were scanned by FD-OCT to map GCC and pRNFL thicknesses. Spearman correlation coefficient was used to assess the correlation between GCC and pRNFL thickness, and pRNFL thickness and optic nerve head (ONH) parameters, including horizontal cup-disc ratio (HCDR), vertical cup-disc ratio (VCDR), optic disc area (ODA), and cup area (CA), respectively. Results The correlation between GCC and pRNFL thickness in the CCG was slightly stronger compared with the ACG. A significant difference in GCC thickness was observed among the CCG, ACG, and NG. Although the pRNFL thickness in both the CCG and ACG was significantly higher than that in NG, no significant difference in pRNFL thickness was detected between the 2 craniopharyngioma groups. The average, superior, and inferior pRNFL thicknesses were negatively correlated with VCDR in the CCG (in double eyes) and ACG (only in left eyes). Conclusions GCC was more sensitive than pRNFL in detecting optic nerve damage in the eyes of craniopharyngioma patients. A thinner pRNFL was especially correlated with VCDR in child craniopharyngioma patients. PMID:27372909
Kwon, Jin Young; Yang, Ji Ho; Han, Ji Sang; Kim, Do Gyun
2017-12-01
To compare the retinal nerve fiber layer (RNFL) as well as the macula volume and thickness in the eyes of age-matched healthy controls with no cognitive disabilities with those of elderly people with mild cognitive impairment (MCI) or Alzheimer disease (AD). We used optical coherence tomography (OCT) to determine the effectiveness of the above quantities for early diagnosis of MCI or AD. Ninety eyes were considered in this study, split between 30 normal eyes, 30 eyes from patients with MCI, and 30eyes from patients with AD. All subjects underwent ophthalmologic and cognitive examinations, and measurements of the RNFL thickness as well as macular volume and thickness were taken for all patients using OCT. The mean RNFL thickness upon OCT was significantly thinner in the AD group than in the MCI group (p = 0.01). The RNFL was thinner in the superior quadrant in patients with AD when compared to the healthy controls (p = 0.03). The RNFL thicknesses in the inferior, nasal, and temporal quadrants did not differ significantly between the groups. Measurements in the 12 clock-hour zones revealed that zone 11 had a significantly thinner RNFL in the AD group as compared with the healthy control group (p = 0.02). In zone 2, the MCI group had a significantly thinner RNFL than the AD group (p = 0.03). Our OCT findings revealed a neuroanatomic difference in the RNFL thickness among the three groups, i.e., the AD, MCI, and healthy control groups. This suggests that a change in average RNFL thickness could be a meaningful index for diagnosing early AD. © 2017 The Korean Ophthalmological Society
Retina nerve fiber layer and choroidal thickness changes in obstructive sleep apnea syndrome.
Ozge, Gokhan; Dogan, Deniz; Koylu, Mehmet Talay; Ayyildiz, Onder; Akincioglu, Dorukcan; Mumcuoglu, Tarkan; Mutlu, Fatih Mehmet
2016-01-01
The purpose of this study was to determine the effects of obstructive sleep apnea syndrome (OSAS) on the submacular and peripapillary retinal nerve fiber layer (RNFL) and choroidal thickness (ChT). Eighty-four eyes of 42 male patients with OSAS and 112 eyes of 56 aged-matched and body mass index-matched healthy male subjects were enrolled in this case-control study. The ChT and peripapillary RNFL thickness was measured using enhanced depth imaging optical coherence tomography. The ChT and RNFL thickness measurements of the groups were compared, and correlations among the Apnea Hypopnea Index (AHI) values and these measurements were calculated. Right and left eyes were separately evaluated. There were no significant differences in the subfoveal and temporal ChT between the groups (p > 0.05). The OSAS group had significantly thicker ChT at 0.5 and 1.5 mm nasal to the fovea in both eyes than the control group (p < 0.05). The peripapillary ChT were significantly thicker in the OSAS group at all segments except for the temporal and superotemporal segments when compared with the control group (p < 0.05 for all quadrants except temporal and superotemporal). When compared with controls, the OSAS group had significantly thinner nasal RNFL thickness in the right eye (p = 0.01) and thinner mean RNFL thickness in both eyes (p < 0.001). Other RNFL thickness measurements were similar between groups (p > 0.05). Between AHI and mean RNFL thickness showed a median negative correlation (r = - 0.411, p = 0.001). The choroidal thickening in patients with OSAS may be associated with the pathophysiology of the neurodegeneration process of the disease.
Wang, Xiao-en; Wang, Xiao-yu; Gu, Yang-shun; Huang, Zhu
2013-01-01
Fundus changes associated with high myopia (HM) may mask those associated with primary open-angle glaucoma (POAG). This study aim to determine the characteristics of RNFL thickness changes in patients with both POAG and HM and compare these to changes in patients with only HM. The diagnostic capabilities of both OCT and GDxVCC in this subset of patients are also evaluated. Twenty-two eyes with POAG and HM (spherical equivalent (SE) between -6.0 and -12.0 D) were evaluated, and 22 eyes with HM were used for comparison. Characteristic retinal nerve fiber layer (RNFL) thickness profiles in patients with POAG and HM were examined using optical coherence tomography (OCT) and scanning laser polarimetry with variable corneal compensation (GDxVCC), and the diagnostic capabilities of these imaging modalities were compared. RNFL parameters evaluated included superior average (Savg-GDx), inferior average (Iavg-GDx), temporal-superior-nasal- inferior-temporal (TSNIT) average, and nerve fiber indicator (NFI) on GDxVCC and superior average (Savg-OCT), inferior average (Iavg-OCT), nasal average (Navg-OCT), temporal average (Tavg-OCT), and average thickness (AvgThick-OCT) on OCT (fast RNFL scan). Visual field testing was performed and defects were evaluated using mean defect (MD) and pattern standard deviation (PSD). The RNFL parameters (P < 0.05) significantly different between groups included Savg-GDx, Iavg-GDx, TSNIT average, NFI, Savg-OCT, Iavg-OCT, Tavg-OCT, and AvgThick-OCT. Significant correlations existed between TSNIT average and AvgThick-OCT (r = 0.778), TSNIT average and MD (r = 0.749), AvgThick-OCT and MD (r = 0.647), TSNIT average and PSD (r = -0.756), and AvgThick-OCT and PSD (r = -0.784). The area under the receiver operating characteristic curve (AUROC) values of TSNIT average, Savg-GDx, Iavg-GDx, NFI, Savg-OCT, Iavg-OCT, Navg-OCT, Tavg-OCT, and AvgThick-OCT were 0.947, 0.962, 0.973, 0.994, 0.909, 0.917, 0.511, 0.906, and 0.913, respectively. The NFI AUROC was the highest value. RNFL thickness was significantly lower in all but the nasal quadrant in patients with POAG and HM, compared to patients with only HM. Measurements with OCT and GDxVCC were well-correlated, and both modalities detected RNFL thickness changes. However, GDxVCC was better than OCT in detecting POAG in HM patients.
NASA Astrophysics Data System (ADS)
Chen, Shuming; Wang, Dengfeng; Liu, Bo
This paper investigates optimization design of the thickness of the sound package performed on a passenger automobile. The major characteristics indexes for performance selected to evaluate the processes are the SPL of the exterior noise and the weight of the sound package, and the corresponding parameters of the sound package are the thickness of the glass wool with aluminum foil for the first layer, the thickness of the glass fiber for the second layer, and the thickness of the PE foam for the third layer. In this paper, the process is fundamentally with multiple performances, thus, the grey relational analysis that utilizes grey relational grade as performance index is especially employed to determine the optimal combination of the thickness of the different layers for the designed sound package. Additionally, in order to evaluate the weighting values corresponding to various performance characteristics, the principal component analysis is used to show their relative importance properly and objectively. The results of the confirmation experiments uncover that grey relational analysis coupled with principal analysis methods can successfully be applied to find the optimal combination of the thickness for each layer of the sound package material. Therefore, the presented method can be an effective tool to improve the vehicle exterior noise and lower the weight of the sound package. In addition, it will also be helpful for other applications in the automotive industry, such as the First Automobile Works in China, Changan Automobile in China, etc.
Retinal Layers Measurements following Silicone Oil Tamponade for Retinal Detachment Surgery.
Jurišić, Darija; Geber, Mia Zorić; Ćavar, Ivan; Utrobičić, Dobrila Karlica
2017-12-19
This study aimed to investigate the influence of silicone oil on the retinal nerve fiber layer (RNFL) thickness in patients with primary rhegmatogenous retinal detachment who underwent vitreoretinal surgery. The study included 47 patients (eyes), who underwent a pars plana vitrectomy with the silicone oil tamponade. The control group included unoperated eye of all participants. Spectral-domain optical coherence tomography (SD-OCT) was used for the measurements of peripapilar and macular RNFL thickness. The average peripapillary RNFL thickness was significantly higher in the silicone oil filled eyes during endotamponade and after its removal. The eyes with elevated IOP had less thickening of the RNFL in comparison to the eyes with normal IOP. Central macular thickness and macular volume were decreased in the silicone oil filled eyes in comparison to the control eyes. In conclusion, silicone oil caused peripapilar RNFL thickening in the vitrectomized eyes during endotamponade and after silicone oil removal.
Fibrous selective emitter structures from sol-gel process
NASA Astrophysics Data System (ADS)
Chen, K. C.
1999-03-01
Selective emitters have the potential benefit of high efficiency due to the matching of emission spectra to the response of photovoltaic (PV) cells. Continuous uniform rare-earth oxide selective emitter fibers were successfully fabricated using a viscous solution made from metal organic precursors. Cylindrical- and planar configuration emitter structures were made by direct cross-winding or stacking of precursor fiber layers. The combustion and optical performance of the planar emitter structures were tested. The results indicates that both the designing of the fiber packing density and the thickness is critical for high photon and power output.
Cone Photoreceptor Packing Density and the Outer Nuclear Layer Thickness in Healthy Subjects
Chui, Toco Y. P.; Song, Hongxin; Clark, Christopher A.; Papay, Joel A.; Burns, Stephen A.; Elsner, Ann E.
2012-01-01
Purpose. We evaluated the relationship between cone photoreceptor packing density and outer nuclear layer (ONL) thickness within the central 15 degrees. Methods. Individual differences for healthy subjects in cone packing density and ONL thickness were examined in 8 younger and 8 older subjects, mean age 27.2 versus 56.2 years. Cone packing density was obtained using an adaptive optics scanning laser ophthalmoscope (AOSLO). The ONL thickness measurements included the ONL and the Henle fiber layer (ONL + HFL), and were obtained using spectral domain optical coherence tomography (SDOCT) and custom segmentation software. Results. There were sizeable individual differences in cone packing density and ONL + HFL thickness. Older subjects had on average lower cone packing densities, but thicker ONL + HFL measurements. Cone packing density and ONL + HFL thickness decreased with increasing retinal eccentricity. The ratio of the cone packing density-to-ONL2 was larger for the younger subjects group, and decreased with retinal eccentricity. Conclusions. The individual differences in cone packing density and ONL + HFL thickness are consistent with aging changes, indicating that normative aging data are necessary for fine comparisons in the early stages of disease or response to treatment. Our finding of ONL + HFL thickness increasing with aging is inconsistent with the hypothesis that ONL measurements with SDOCT depend only on the number of functioning cones, since in our older group cones were fewer, but thickness was greater. PMID:22570340
Preparation and properties of the multi-layer aerogel thermal insulation composites
NASA Astrophysics Data System (ADS)
Wang, Miao; Feng, Junzong; Jiang, Yonggang; Zhang, Zhongming; Feng, Jian
2018-03-01
Multi-layer insulation materials possess low radiation thermal conductivity, and excellent thermal insulation property in a vacuum environment. However, the spacers of the traditional multi-layer insulation materials are mostly loose fibers, which lead to more sensitive to the vacuum environmental of serviced. With the vacuum degree declining, gas phases thermal convection increase obviously, and the reflective screen will be severe oxidation, all of these make the thermal insulation property of traditional multi-layer insulation deteriorate, thus limits its application scope. In this paper, traditional multi-layer insulation material is combined with aerogel and obtain a new multi-layer aerogel thermal insulation composite, and the effects of the number, thickness and type of the reflective screens on the thermal insulation properties of the multi-layer composites are also studied. The result is that the thermal insulation property of the new type multi-layer aerogel composites is better than the pure aerogel composites and the traditional multi-layer insulation composites. When the 0.01 mm stainless steel foil as the reflective screen, and the aluminum silicate fiber and silica aerogel as the spacer layer, the layer density of composite with the best thermal insulation property is one layer per millimeter at 1000 °C.
Barboni, Piero; Carbonelli, Michele; Savini, Giacomo; Ramos, Carolina do V F; Carta, Arturo; Berezovsky, Adriana; Salomao, Solange R; Carelli, Valerio; Sadun, Alfredo A
2010-03-01
To investigate by optical coherence tomography (OCT) the topographic pattern and temporal sequence of fiber loss in the peripapillary retinal nerve fiber layer (RNFL) of patients with Leber's hereditary optic neuropathy (LHON) in a longitudinal follow-up. Cohort study. Six eyes of 4 patients with molecularly defined LHON were enrolled before the subacute period of visual loss. Subjects were studied by StratusOCT (Carl Zeiss Meditec, Inc., Dublin, CA) during a 9-month follow-up starting from the presymptomatic stage of the disease. Examinations were carried out at 4 different time points: presymptomatic stage, time of visual loss, and 3 and 9 months later. Peripapillary RNFL thickness for each quadrant of the optic nerve. Statistical comparisons were performed by ordinary analysis of variance with Dunnett's post-test. A significant increase of RNFL thickness was detected in the temporal and inferior quadrants between the presymptomatic stage and the disease onset (P<0.05). The 360-degree average and the superior and nasal quadrants showed a nonstatistically significant increase of thickness at this time. In the 360-degree average (P<0.01), superior (P<0.01), nasal (P<0.05), and inferior (P<0.01) quadrants, RNFL thickening showed statistically significant changes between the presymptomatic stage and the 3-month follow-up. At 3 months, a nonsignificant reduction of RNFL thickness was detected in the temporal quadrant. A significant reduction of RNFL was detected in all but the nasal quadrants between the presymptomatic stage and the 9-month Follow-up. The RNFL thickness increase first appeared at the temporal and inferior quadrants. Conversely, at 3 months the thickening fibers were more evident in the superior and nasal quadrants. These findings are consistent with the established preferential early involvement of the papillomacular bundle in LHON. We also demonstrated the previously unrecognized simultaneous early involvement of the inferior quadrant. The late involvement of both superior and nasal quadrants suggests a dynamic evolution of the acute stage that continues for 3 months and may represent a therapeutic window of opportunity. Copyright 2010 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Distributing Radiant Heat in Insulation Tests
NASA Technical Reports Server (NTRS)
Freitag, H. J.; Reyes, A. R.; Ammerman, M. C.
1986-01-01
Thermally radiating blanket of stepped thickness distributes heat over insulation sample during thermal vacuum testing. Woven of silicon carbide fibers, blanket spreads heat from quartz lamps evenly over insulation sample. Because of fewer blanket layers toward periphery of sample, more heat initially penetrates there for more uniform heat distribution.
NASA Astrophysics Data System (ADS)
Kawai, E.; Umeno, Y.
2017-05-01
As weight reduction of turbines for aircraft engines is demanded to improve fuel consumption and curb emission of carbon dioxide, silicon carbide (SiC) fiber reinforced SiC matrix composites (SiC/SiC) are drawing enormous attention as high-pressure turbine materials. For preventing degradation of SiC/SiC, environmental barrier coatings (EBC) for ceramics are deposited on the composites. The purpose of this study is to establish theoretical guidelines for structural design which ensures the mechanical reliability of EBC. We conducted finite element method (FEM) analysis to calculate energy release rates (ERRs) for interface crack initiation due to thermal stress in EBC consisting of Si-based bond coat, Mullite and Ytterbium (Yb)-silicate layers on a SiC/SiC substrate. In the FEM analysis, the thickness of one EBC layer was changed from 25 μm to 200 μm while the thicknesses of the other layers were fixed at 25 μm, 50 μm and 100 μm. We compared ERRs obtained by the FEM analysis and a simple theory for interface crack in a single-layered structure where ERR is estimated as nominal strain energy in the coating layers multiplied by a constant factor (independent of layer thicknesses). We found that, unlike the case of single-layered structures, the multiplication factor is no longer a constant but is determined by the combination of consisting coating layer thicknesses.
Rajjoub, Raneem D; Trimboli-Heidler, Carmelina; Packer, Roger J; Avery, Robert A
2015-01-01
To determine the intra- and intervisit reproducibility of circumpapillary retinal nerve fiber layer (RNFL) thickness measures using eye tracking-assisted spectral-domain optical coherence tomography (SD OCT) in children with nonglaucomatous optic neuropathy. Prospective longitudinal study. Circumpapillary RNFL thickness measures were acquired with SD OCT using the eye-tracking feature at 2 separate study visits. Children with normal and abnormal vision (visual acuity ≥ 0.2 logMAR above normal and/or visual field loss) who demonstrated clinical and radiographic stability were enrolled. Intra- and intervisit reproducibility was calculated for the global average and 9 anatomic sectors by calculating the coefficient of variation and intraclass correlation coefficient. Forty-two subjects (median age 8.6 years, range 3.9-18.2 years) met inclusion criteria and contributed 62 study eyes. Both the abnormal and normal vision cohort demonstrated the lowest intravisit coefficient of variation for the global RNFL thickness. Intervisit reproducibility remained good for those with normal and abnormal vision, although small but statistically significant increases in the coefficient of variation were observed for multiple anatomic sectors in both cohorts. The magnitude of visual acuity loss was significantly associated with the global (ß = 0.026, P < .01) and temporal sector coefficient of variation (ß = 0.099, P < .01). SD OCT with eye tracking demonstrates highly reproducible RNFL thickness measures. Subjects with vision loss demonstrate greater intra- and intervisit variability than those with normal vision. Copyright © 2015 Elsevier Inc. All rights reserved.
Skieresz-Szewczyk, Kinga; Jackowiak, Hanna; Ratajczak, Marlena
2014-12-01
The previous histological studies of the lingual mucosa in birds characterized two types of keratinized epithelium, i.e. orthokeratinized and parakeratinized. These epithelia are composed of three layers: basal, intermediate and keratinized. The present study showed detailed ultrastructural features of cells in particular layers of two types of keratinized epithelia on the tongue in the domestic duck and defined structural differences. TEM observations showed a gradual reduction in cell organelles in the following layers, at increasing amounts of keratin fibers. The characteristic feature of the ortho- and parakeratinized epithelium is the presence of sub-layers in the intermediate layer, i.e. the upper and lower part, which results from the different shape of cell nuclei and dye affinity of the cytoplasm. The keratinized layer of ortho- and parakeratinized epithelium is built of two types of cells such as electron dark and light cells, which undergo exfoliation. The basic difference between the keratinized epithelia is the presence of flattened cell nuclei in the keratinized layer of the parakeratinized epithelium. The differentiating feature is also an arrangement of keratin fibers in the cell cytoplasm of the keratinized layer. The analysis of the thickness of the epithelium and the keratinized layer, indicated differences between keratinized epithelia, which result from two variants of performing protective functions, either through a thick keratinized layer or by a higher epithelium. Differences in the ultrastructure of the ortho- and parakeratinized epithelium are associated with mechanical functions of the epithelium resulting from different forces acting on the tongue during feeding activities. Copyright © 2014 Elsevier Ltd. All rights reserved.
Structural investigations of human hairs by spectrally resolved ellipsometry
NASA Astrophysics Data System (ADS)
Chan, Danny; Schulz, Benjamin; Rübhausen, Michael; Wessel, Sonya; Wepf, Roger
2006-01-01
Human hair is a biological layered system composed of two major layers, the cortex and the cuticle. We show spectrally resolved ellipsometry measurements of the ellipsometric parameters Ψ and Δ of single human hairs. The spectra reflect the layered nature of hair and the optical anisotropy of the hair's structure. In addition, measurements on strands of human hair show a high reproducibility of the ellipsometric parameters for different hair fiber bundles from the same person. Based on the measurements, we describe a dielectric model of hair that explains the spectra in terms of the dielectric properties of the major parts of hair and their associated layer thicknesses. In addition, surface roughness effects modeled by a roughness layer with a complex refractive index given by an effective medium approach can be seen to have a significant effect on the measurements. We derive values for the parameters of the cuticle surface roughness layer of the thickness dACu=273 to 360 nm and the air inclusion fA=0.6 to 5.7%.
Characteristics of peripapillary retinal nerve fiber layer in preterm children.
Wang, Jingyun; Spencer, Rand; Leffler, Joel N; Birch, Eileen E
2012-05-01
To examine quantitatively characteristics of the peripapillary retinal nerve fiber layer (RNFL) in preterm children using Fourier-domain optical coherence tomography (FD-OCT). Prospective cross-sectional study. A 3-mm high-resolution FD-OCT peripapillary RNFL circular scan centered on the optic disc was obtained from right eyes of 25 preterm children (10.6 ± 3.7 years old, 8 preterm and 17 with regressed retinopathy of prematurity with normal-appearing posterior poles) and 54 full-term controls (9.8 ± 3.2 years old). Images were analyzed using Spectralis FD-OCT software to obtain average thickness measurements for 6 sectors (temporal superior, temporal, temporal inferior, nasal inferior, nasal, nasal superior), and the global average. The RNFL global average for preterm children was 8% thinner than for full-term controls. In the preterm group, peripapillary RNFL thickness on the temporal side of the disc was 6% thicker than in full-term controls, while all other peripapillary RNFL sectors were 9% to 13% thinner. In the preterm group, temporal sector peripapillary RNFL thickness was correlated with gestational age (r = -0.47, P < .001), with foveal center total thickness (r = 0.48, P = .008, 1-tailed), and with visual acuity (r = 0.42; P = .026, 1-tailed). The significantly thinner RNFL global average for preterm children suggests that prematurity is associated with subclinical optic nerve hypoplasia. Significant correlations between temporal sector RNFL thickness and both the foveal thickness and visual acuity suggest that the peripapillary RNFL is related to abnormalities in macular development as a result of preterm birth. Copyright © 2012 Elsevier Inc. All rights reserved.
Soler García, A; Padilla Parrado, F; Figueroa-Ortiz, L C; González Gómez, A; García-Ben, A; García-Ben, E; García-Campos, J M
2016-01-01
Quantitative assessment of macular and nerve fibre layer thickness in multiple sclerosis patients with regard to expanded disability status scale (EDSS) and presence or absence of previous optic neuritis episodes. We recruited 62 patients with multiple sclerosis (53 relapsing-remitting and 9 secondary progressive) and 12 disease-free controls. All patients underwent an ophthalmological examination, including quantitative analysis of the nerve fibre layer and macular thickness using optical coherence tomography. Patients were classified according to EDSS as A (lower than 1.5), B (between 1.5 and 3.5), and C (above 3.5). Mean nerve fibre layer thickness in control, A, B, and C groups was 103.35±12.62, 99.04±14.35, 93.59±15.41, and 87.36±18.75μm respectively, with statistically significant differences (P<.05). In patients with no history of optic neuritis, history of episodes in the last 3 to 6 months, or history longer than 6 months, mean nerve fibre layer thickness was 99.25±13.71, 93.92±13.30 and 80.07±15.91μm respectively; differences were significant (P<.05). Mean macular thickness in control, A, B, and C groups was 220.01±12.07, 217.78±20.02, 217.68±20.77, and 219.04±24.26μm respectively. Differences were not statistically significant. The mean retinal nerve fibre layer thickness in multiple sclerosis patients is related to the EDSS level. Patients with previous optic neuritis episodes have a thinner retinal nerve fibre layer than patients with no history of these episodes. Mean macular thickness is not correlated to EDSS level. Copyright © 2014 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.
Tunç, Abdulkadir; Güngen, Belma Doğan; Evliyaoğlu, Ferhat; Aras, Yeşim Güzey; Tekeşin, Aysel Kaya
2017-03-01
The aim of this study was to investigate retinal nerve fiber layer (RNFL), ganglion cell layer (GCL) thickness, macular changes (central subfield thickness (CST), cube average thickness (CAT), cube volume (CV) in patients with migraine using spectral-domain optical coherence tomography (OCT) and to assess if there was any correlation with white matter lesions (WML). In this prospective case-control study, RNFL, GCL thickness and macular changes of 19 migraine patients with aura (MA), 41 migraine without aura (MO) and 60 age- and gender-matched healthy subjects were measured using OCT device. OCT measurements were taken at the same time of the day to minimize the effects of diurnal variation. The average, inferior and superior quadrant RNFL thickness were significantly thinner in patients with migraine (p = 0.017, p = 0.010, p = 0.048). There was also a significant difference between patients with and without aura in the mean and superior quadrant RNFL thickness (p = 0.02, p = 0.043).While there was a significant thinning in CST and CAT in patients with migraine (p = 0.020), there were no significant difference in GCL measurements (p = 0.184). When the groups were compared to the control group, there were significant differences between MA and the control group regarding average, superior and inferior quadrant RNLF thickness (p < 0.001, p = 0.025, p < 0.001). On the other hand, there were significant differences between MO and the control group regarding average and inferior faces (p = 0.037, p = 0.04). When OCT measurements were evaluated according to the frequency of attacks, CST and GCL thickness were significantly thinner in patients who had more than four attacks a month (p = 0.024, p = 0.014). In patients with WML, only CV measurements were significantly thinner than migraine patients without WML (p = 0.014). The decreased RNFL, CST, CAT and CV of the migraine patients might be related to the vascular pathology of the disease. Because WML was not correlated with the same measurements except CV, we think that further studies are needed to evaluate the etiopathologic relationship between OCT measurements and WML in migraine patients.
Gonzalez Caldito, Natalia; Antony, Bhavna; He, Yufan; Lang, Andrew; Nguyen, James; Rothman, Alissa; Ogbuokiri, Esther; Avornu, Ama; Balcer, Laura; Frohman, Elliot; Frohman, Teresa C; Bhargava, Pavan; Prince, Jerry; Calabresi, Peter A; Saidha, Shiv
2018-03-01
Optical coherence tomography (OCT) is a reliable method used to quantify discrete layers of the retina. Spectralis OCT is a device used for this purpose. Spectralis OCT macular scan imaging acquisition can be obtained on either the horizontal or vertical plane. The vertical protocol has been proposed as favorable, due to postulated reduction in confound of Henle's fibers on segmentation-derived metrics. Yet, agreement of the segmentation measures of horizontal and vertical macular scans remains unexplored. Our aim was to determine this agreement. Horizontal and vertical macular scans on Spectralis OCT were acquired in 20 healthy controls (HCs) and 20 multiple sclerosis (MS) patients. All scans were segmented using Heidelberg software and a Johns Hopkins University (JHU)-developed method. Agreement was analyzed using Bland-Altman analyses and intra-class correlation coefficients (ICCs). Using both segmentation techniques, mean differences (agreement at the cohort level) in the thicknesses of all macular layers derived from both acquisition protocols in MS patients and HCs were narrow (<1 µm), while the limits of agreement (LOA) (agreement at the individual level) were wider. Using JHU segmentation mean differences (and LOA) for the macular retinal nerve fiber layer (RNFL) and ganglion cell layer + inner plexiform layer (GCIP) in MS were 0.21 µm (-1.57-1.99 µm) and -0.36 µm (-1.44-1.37 µm), respectively. OCT segmentation measures of discrete retinal-layer thicknesses derived from both vertical and horizontal protocols on Spectralis OCT agree excellently at the cohort level (narrow mean differences), but only moderately at the individual level (wide LOA). This suggests patients scanned using either protocol should continue to be scanned with the same protocol. However, due to excellent agreement at the cohort level, measures derived from both acquisitions can be pooled for outcome purposes in clinical trials.
Bae, Hyoung Won; Lee, Sang Yeop; Kim, Sangah; Park, Chan Keum; Lee, Kwanghyun; Kim, Chan Yun; Seong, Gong Je
2018-01-01
To assess whether the asymmetry in the peripapillary retinal nerve fiber layer (pRNFL) thickness between superior and inferior hemispheres on optical coherence tomography (OCT) is useful for early detection of glaucoma. The patient population consisted of Training set (a total of 60 subjects with early glaucoma and 59 normal subjects) and Validation set (30 subjects with early glaucoma and 30 normal subjects). Two kinds of ratios were employed to measure the asymmetry between the superior and inferior pRNFL thickness using OCT. One was the ratio of the superior to inferior peak thicknesses (peak pRNFL thickness ratio; PTR), and the other was the ratio of the superior to inferior average thickness (average pRNFL thickness ratio; ATR). The diagnostic abilities of the PTR and ATR were compared to the color code classification in OCT. Using the optimal cut-off values of the PTR and ATR obtained from the Training set, the two ratios were independently validated for diagnostic capability. For the Training set, the sensitivities/specificities of the PTR, ATR, quadrants color code classification, and clock-hour color code classification were 81.7%/93.2%, 71.7%/74.6%, 75.0%/93.2%, and 75.0%/79.7%, respectively. The PTR showed a better diagnostic performance for early glaucoma detection than the ATR and the clock-hour color code classification in terms of areas under the receiver operating characteristic curves (AUCs) (0.898, 0.765, and 0.773, respectively). For the Validation set, the PTR also showed the best sensitivity and AUC. The PTR is a simple method with considerable diagnostic ability for early glaucoma detection. It can, therefore, be widely used as a new screening method for early glaucoma. © Copyright: Yonsei University College of Medicine 2018
Gabriele, Michelle L.; Ishikawa, Hiroshi; Wollstein, Gadi; Bilonick, Richard A.; Townsend, Kelly A.; Kagemann, Larry; Wojtkowski, Maciej; Srinivasan, Vivek J.; Fujimoto, James G.; Duker, Jay S.; Schuman, Joel S.
2009-01-01
PURPOSE To investigate the effect on optical coherence tomography (OCT) retinal nerve fiber layer (RNFL) thickness measurements of varying the standard 3.4-mm-diameter circle location. METHODS The optic nerve head (ONH) region of 17 eyes of 17 healthy subjects was imaged with high-speed, ultrahigh-resolution OCT (hsUHR-OCT; 501 × 180 axial scans covering a 6 × 6-mm area; scan time, 3.84 seconds) for a comprehensive sampling. This method allows for systematic simulation of the variable circle placement effect. RNFL thickness was measured on this three-dimensional dataset by using a custom-designed software program. RNFL thickness was resampled along a 3.4-mm-diameter circle centered on the ONH, then along 3.4-mm circles shifted horizontally (x-shift), vertically (y-shift) and diagonally up to ±500 µm (at 100-µm intervals). Linear mixed-effects models were used to determine RNFL thickness as a function of the scan circle shift. A model for the distance between the two thickest measurements along the RNFL thickness circular profile (peak distance) was also calculated. RESULTS RNFL thickness tended to decrease with both positive and negative x- and y-shifts. The range of shifts that caused a decrease greater than the variability inherent to the commercial device was greater in both nasal and temporal quadrants than in the superior and inferior ones. The model for peak distance demonstrated that as the scan moves nasally, the RNFL peak distance increases, and as the circle moves temporally, the distance decreases. Vertical shifts had a minimal effect on peak distance. CONCLUSIONS The location of the OCT scan circle affects RNFL thickness measurements. Accurate registration of OCT scans is essential for measurement reproducibility and longitudinal examination (ClinicalTrials.gov number, NCT00286637). PMID:18515577
Modular assembly of thick multifunctional cardiac patches
Fleischer, Sharon; Shapira, Assaf; Feiner, Ron; Dvir, Tal
2017-01-01
In cardiac tissue engineering cells are seeded within porous biomaterial scaffolds to create functional cardiac patches. Here, we report on a bottom-up approach to assemble a modular tissue consisting of multiple layers with distinct structures and functions. Albumin electrospun fiber scaffolds were laser-patterned to create microgrooves for engineering aligned cardiac tissues exhibiting anisotropic electrical signal propagation. Microchannels were patterned within the scaffolds and seeded with endothelial cells to form closed lumens. Moreover, cage-like structures were patterned within the scaffolds and accommodated poly(lactic-co-glycolic acid) (PLGA) microparticulate systems that controlled the release of VEGF, which promotes vascularization, or dexamethasone, an anti-inflammatory agent. The structure, morphology, and function of each layer were characterized, and the tissue layers were grown separately in their optimal conditions. Before transplantation the tissue and microparticulate layers were integrated by an ECM-based biological glue to form thick 3D cardiac patches. Finally, the patches were transplanted in rats, and their vascularization was assessed. Because of the simple modularity of this approach, we believe that it could be used in the future to assemble other multicellular, thick, 3D, functional tissues. PMID:28167795
Kim, Ho Soong; Yang, Heon; Lee, Tae Heon; Lee, Kyung Heon
2016-06-01
To determine the diagnostic value of the ganglion cell-inner plexiform layer (GCIPL) thickness in glaucomatous eyes with superior or inferior visual hemifield defects. Eighty-five patients with glaucoma (42 isolated superior hemifield defects and 43 isolated inferior hemifield defects) and 46 normal subjects were enrolled. All patients underwent Cirrus high-definition optical coherence tomography and standard automated perimetry. The area under the receiver operating characteristic curve (AUC) was calculated to determine the diagnostic ability of the GCIPL and peripapillary retinal nerve fiber layer (pRNFL). In the superior hemifield defect glaucoma group, the best parameters for discriminating normal eyes from glaucomatous eyes were the inferotemporal GCIPL thickness (0.942), inferior quadrant RNFL thickness (0.974), and 7 o'clock sector RNFL thickness (0.999). For diagnosing inferior hemifield defect glaucoma, the AUCs of all GCIPL parameters (0.331 to 0.702) were significantly lower than that of the superior quadrant RNFL thickness (0.866, P<0.05). The diagnostic ability of GCIPL parameters was similar to that of the pRNFL parameters in superior hemifield defect glaucoma. However, the diagnostic performance of the GCIPL parameters was significantly inferior to those of the pRNFL parameters in eyes with inferior hemifield defect glaucoma.
Large-scale, thick, self-assembled, nacre-mimetic brick-walls as fire barrier coatings on textiles
NASA Astrophysics Data System (ADS)
Das, Paramita; Thomas, Helga; Moeller, Martin; Walther, Andreas
2017-01-01
Highly loaded polymer/clay nanocomposites with layered structures are emerging as robust fire retardant surface coatings. However, time-intensive sequential deposition processes, e.g. layer-by-layer strategies, hinders obtaining large coating thicknesses and complicates an implementation into existing technologies. Here, we demonstrate a single-step, water-borne approach to prepare thick, self-assembling, hybrid fire barrier coatings of sodium carboxymethyl cellulose (CMC)/montmorillonite (MTM) with well-defined, bioinspired brick-wall nanostructure, and showcase their application on textile. The coating thickness on the textile is tailored using different concentrations of CMC/MTM (1-5 wt%) in the coating bath. While lower concentrations impart conformal coatings of fibers, thicker continuous coatings are obtained on the textile surface from highest concentration. Comprehensive fire barrier and fire retardancy tests elucidate the increasing fire barrier and retardancy properties with increasing coating thickness. The materials are free of halogen and heavy metal atoms, and are sourced from sustainable and partly even renewable building blocks. We further introduce an amphiphobic surface modification on the coating to impart oil and water repellency, as well as self-cleaning features. Hence, our study presents a generic, environmentally friendly, scalable, and one-pot coating approach that can be introduced into existing technologies to prepare bioinspired, thick, fire barrier nanocomposite coatings on diverse surfaces.
García-Medina, José Javier; García-Piñero, María; Del-Río-Vellosillo, Mónica; Fares-Valdivia, Jesarán; Ragel-Hernández, Ana Belén; Martínez-Saura, Salvador; Cárcel-López, María Dolores; Zanon-Moreno, Vicente; Pinazo-Duran, María Dolores; Villegas-Pérez, María Paz
2017-11-01
To compare thicknesses of intraretinal layers segmented by spectral-domain optical coherence tomography (SD-OCT) between autism spectrum disorder (ASD) and neurotypical (NT) individuals. We performed 2 scans on 108 eyes from 54 participants (27 high-functioning ASD and 27 age- and sex-matched NT subjects): macular fast volume and peripapillary retinal nerve fiber layer (pRNFL). Macula was automatically segmented. The mean foveal and macular thickness of nine different layers and the thickness of nine pRNFL sectors were considered. Data from the right and left eyes were averaged for each participant. The results were compared between the ASD and NT groups. Associations between the Kaufman brief intelligence test (K-BIT), head circumference and SD-OCT results were also investigated in ASD individuals. ASD subjects showed greater foveal thickness at total retina, total inner retina, inner plexiform and inner nuclear layers, and greater macular thickness at total retina and total inner retina. Inferior, nasal inferior and temporal inferior sectors of pRNFL were also thicker in the ASD participants than in the controls (P < 0.05, unpaired t-test). Significant correlations were found between some K-BIT results and temporal inferior and inferior pRNFL thicknesses in the ASD group (P < 0.05, Spearman's rank correlation). No associations were seen between head circumference and OCT parameters. There are intraretinal thickenings at different locations in ASD subjects when compared to NT controls. This fact should be taken into account when interpreting SD-OCT examinations in ASD individuals. Plus, some pRNFL thicknesses present positive correlations with scores of cognitive status in ASD.
Fan, Kenneth Chen; Tsikata, Edem; Khoueir, Ziad; Simavli, Huseyin; Guo, Rong; DeLuna, Regina; Pandit, Sumir; Que, Christian John; de Boer, Johannes F.; Chen, Teresa C.
2017-01-01
Purpose To compare the diagnostic capability of 3-dimensional (3D) neuroretinal rim parameters with existing 2-dimensional (2D) neuroretinal and retinal nerve fiber layer (RNFL) thickness rim parameters using spectral domain optical coherence tomography (SD-OCT) volume scans Materials and Methods Design Institutional prospective pilot study. Study population 65 subjects (35 open angle glaucoma patients, 30 normal patients). Observation procedures One eye of each subject was included. SD-OCT was used to obtain 2D retinal nerve fiber layer (RNFL) thickness values and five neuroretinal rim parameters [i.e. 3D minimum distance band (MDB) thickness, 3D Bruch’s membrane opening-minimum rim width (BMO-MRW), 3D rim volume, 2D rim area, and 2D rim thickness]. Main outcome measures Area under the receiver operating characteristic (AUROC) curve values, sensitivity, specificity. Results Comparing all 3D with all 2D parameters, 3D rim parameters (MDB, BMO-MRW, rim volume) generally had higher AUROC curve values (range 0.770–0.946) compared to 2D parameters (RNFL thickness, rim area, rim thickness; range 0.678–0.911). For global region analyses, all 3D rim parameters (BMO-MRW, rim volume, MDB) were equal to or better than 2D parameters (RNFL thickness, rim area, rim thickness; p-values from 0.023–1.0). Among the three 3D rim parameters (MDB, BMO-MRW, and rim volume), there were no significant differences in diagnostic capability (false discovery rate > 0.05 at 95% specificity). Conclusion 3D neuroretinal rim parameters (MDB, BMO-MRW, and rim volume) demonstrated better diagnostic capability for primary and secondary open angle glaucomas compared to 2D neuroretinal parameters (rim area, rim thickness). Compared to 2D RNFL thickness, 3D neuroretinal rim parameters have the same or better diagnostic capability. PMID:28234677
Three-dimensional retinal imaging with high-speed ultrahigh-resolution optical coherence tomography.
Wojtkowski, Maciej; Srinivasan, Vivek; Fujimoto, James G; Ko, Tony; Schuman, Joel S; Kowalczyk, Andrzej; Duker, Jay S
2005-10-01
To demonstrate high-speed, ultrahigh-resolution, 3-dimensional optical coherence tomography (3D OCT) and new protocols for retinal imaging. Ultrahigh-resolution OCT using broadband light sources achieves axial image resolutions of approximately 2 microm compared with standard 10-microm-resolution OCT current commercial instruments. High-speed OCT using spectral/Fourier domain detection enables dramatic increases in imaging speeds. Three-dimensional OCT retinal imaging is performed in normal human subjects using high-speed ultrahigh-resolution OCT. Three-dimensional OCT data of the macula and optic disc are acquired using a dense raster scan pattern. New processing and display methods for generating virtual OCT fundus images; cross-sectional OCT images with arbitrary orientations; quantitative maps of retinal, nerve fiber layer, and other intraretinal layer thicknesses; and optic nerve head topographic parameters are demonstrated. Three-dimensional OCT imaging enables new imaging protocols that improve visualization and mapping of retinal microstructure. An OCT fundus image can be generated directly from the 3D OCT data, which enables precise and repeatable registration of cross-sectional OCT images and thickness maps with fundus features. Optical coherence tomography images with arbitrary orientations, such as circumpapillary scans, can be generated from 3D OCT data. Mapping of total retinal thickness and thicknesses of the nerve fiber layer, photoreceptor layer, and other intraretinal layers is demonstrated. Measurement of optic nerve head topography and disc parameters is also possible. Three-dimensional OCT enables measurements that are similar to those of standard instruments, including the StratusOCT, GDx, HRT, and RTA. Three-dimensional OCT imaging can be performed using high-speed ultrahigh-resolution OCT. Three-dimensional OCT provides comprehensive visualization and mapping of retinal microstructures. The high data acquisition speeds enable high-density data sets with large numbers of transverse positions on the retina, which reduces the possibility of missing focal pathologies. In addition to providing image information such as OCT cross-sectional images, OCT fundus images, and 3D rendering, quantitative measurement and mapping of intraretinal layer thickness and topographic features of the optic disc are possible. We hope that 3D OCT imaging may help to elucidate the structural changes associated with retinal disease as well as improve early diagnosis and monitoring of disease progression and response to treatment.
Imaging retinal nerve fiber bundles using optical coherence tomography with adaptive optics.
Kocaoglu, Omer P; Cense, Barry; Jonnal, Ravi S; Wang, Qiang; Lee, Sangyeol; Gao, Weihua; Miller, Donald T
2011-08-15
Early detection of axonal tissue loss in retinal nerve fiber layer (RNFL) is critical for effective treatment and management of diseases such as glaucoma. This study aims to evaluate the capability of ultrahigh-resolution optical coherence tomography with adaptive optics (UHR-AO-OCT) for imaging the RNFL axonal bundles (RNFBs) with 3×3×3μm(3) resolution in the eye. We used a research-grade UHR-AO-OCT system to acquire 3°×3° volumes in four normal subjects and one subject with an arcuate retinal nerve fiber layer defect (n=5; 29-62years). Cross section (B-scans) and en face (C-scan) slices extracted from the volumes were used to assess visibility and size distribution of individual RNFBs. In one subject, we reimaged the same RNFBs twice over a 7month interval and compared bundle width and thickness between the two imaging sessions. Lastly we compared images of an arcuate RNFL defect acquired with UHR-AO-OCT and commercial OCT (Heidelberg Spectralis). Individual RNFBs were distinguishable in all subjects at 3° retinal eccentricity in both cross-sectional and en face views (width: 30-50μm, thickness: 10-15μm). At 6° retinal eccentricity, RNFBs were distinguishable in three of the five subjects in both views (width: 30-45μm, thickness: 20-40μm). Width and thickness RNFB measurements taken 7months apart were strongly correlated (p<0.0005). Mean difference and standard deviation of the differences between the two measurement sessions were -0.1±4.0μm (width) and 0.3±1.5μm (thickness). UHR-AO-OCT outperformed commercial OCT in terms of clarity of the microscopic retina. To our knowledge, these are the first measurements of RNFB cross section reported in the living human eye. Copyright © 2011 Elsevier Ltd. All rights reserved.
Imaging retinal nerve fiber bundles using optical coherence tomography with adaptive optics
Kocaoglu, Omer P.; Cense, Barry; Jonnal, Ravi S.; Wang, Qiang; Lee, Sangyeol; Gao, Weihua; Miller, Donald T.
2011-01-01
Early detection of axonal tissue loss in retinal nerve fiber layer (RNFL) is critical for effective treatment and management of diseases such as glaucoma. This study aims to evaluate the capability of ultrahigh-resolution optical coherence tomography with adaptive optics (UHR-AO-OCT) for imaging the RNFL axonal bundles (RNFBs) with 3×3×3 μm3 resolution in the eye. We used a research-grade UHR-AO-OCT system to acquire 3°×3° volumes in four normal subjects and one subject with an arcuate retinal nerve fiber layer defect (n=5; 29–62yrs). Cross section (B-scans) and en face (C-scan) slices extracted from the volumes were used to assess visibility and size distribution of individual RNFBs. In one subject, we reimaged the same RNFBs twice over a seven month interval and compared bundle width and thickness between the two imaging sessions. Lastly we compared images of an arcuate RNFL defect acquired with UHR-AO-OCT and commercial OCT (Heidelberg Spectralis). Individual RNFBs were distinguishable in all subjects at 3° retinal eccentricity in both cross-sectional and en face views (width: 30–50μm, thickness: 10–15μm). At 6° retinal eccentricity, RNFBs were distinguishable in three of the five subjects in both views (width: 30–45μm, thickness: 20–40μm). Width and thickness RNFB measurements taken seven months apart were strongly correlated (p<0.0005). Mean difference and standard deviation of the differences between the two measurement sessions were −0.1±4.0 μm (width) and 0.3±1.5 μm (thickness). UHR-AO-OCT outperformed commercial OCT in terms of clarity of the microscopic retina. To our knowledge, these are the first measurements of RNFB cross section reported in the living human eye. PMID:21722662
Agarose coated spherical micro resonator for humidity measurements.
Mallik, Arun Kumar; Liu, Dejun; Kavungal, Vishnu; Wu, Qiang; Farrell, Gerald; Semenova, Yuliya
2016-09-19
A new type of fiber optic relative humidity (RH) sensor based on an agarose coated silica microsphere resonator is proposed and experimentally demonstrated. Whispering gallery modes (WGMs) in the micro resonator are excited by evanescent coupling using a tapered fiber with ~3.3 µm waist diameter. A change in the relative humidity of the surrounding the resonator air induces changes in the refractive index (RI) and thickness of the Agarose coating layer. These changes in turn lead to a spectral shift of the WGM resonances, which can be related to the RH value after a suitable calibration. Studies of the repeatability, long-term stability, measurement accuracy and temperature dependence of the proposed sensor are carried out. The RH sensitivity of the proposed sensor depends on the concentration of the agarose gel which determines the initial thickness of the deposited coating layer. Studies of the micro- resonators with coating layers fabricated from gels with three different Agarose concentrations of 0.5%, 1.125% and 2.25 wt./vol.% showed that an increase in the initial thickness of the coating material results in an increase in sensitivity but also leads to a decrease of quality factor (Q) of the micro resonator. The highest sensitivity achieved in our experiments was 518 pm/%RH in the RH range from 30% to 70%. The proposed sensor offers the advantages of a very compact form factor, low hysteresis, good repeatability, and low cross sensitivity to temperature.
Assembly of optical fibers for the connection of polymer-based waveguide
NASA Astrophysics Data System (ADS)
Ansel, Yannick; Grau, Daniel; Holzki, Markus; Kraus, Silvio; Neumann, Frank; Reinhard, Carsten; Schmitz, Felix
2003-03-01
This paper describes the realization of polymer-based optical structures and the assembly and packaging strategy to connect optical fiber ribbons to the waveguides. For that a low cost fabrication process using the SU-8TM thick photo-resist is presented. This process consists in the deposition of two photo-structurized resist layers filled up with epoxy glue realising the core waveguide. For the assembly, a new modular vacuum gripper was realised and installed on an automatic pick and place assembly robot to mount precisely and efficiently the optical fibers in the optical structures. First results have shown acceptable optical propagation loss for the complete test structure.
Miller, Philip R.; Gittard, Shaun D.; Edwards, Thayne L.; Lopez, DeAnna M.; Xiao, Xiaoyin; Wheeler, David R.; Monteiro-Riviere, Nancy A.; Brozik, Susan M.; Polsky, Ronen; Narayan, Roger J.
2011-01-01
In this study, carbon fiber electrodes were incorporated within a hollow microneedle array, which was fabricated using a digital micromirror device-based stereolithography instrument. Cell proliferation on the acrylate-based polymer used in microneedle fabrication was examined with human dermal fibroblasts and neonatal human epidermal keratinocytes. Studies involving full-thickness cadaveric porcine skin and trypan blue dye demonstrated that the hollow microneedles remained intact after puncturing the outermost layer of cadaveric porcine skin. The carbon fibers underwent chemical modification in order to enable detection of hydrogen peroxide and ascorbic acid; electrochemical measurements were demonstrated using integrated electrode-hollow microneedle devices. PMID:21522504
"Brick-and-Mortar" Nanostructured Interphase for Glass-Fiber-Reinforced Polymer Composites.
De Luca, Francois; Sernicola, Giorgio; Shaffer, Milo S P; Bismarck, Alexander
2018-02-28
The fiber-matrix interface plays a critical role in determining composite mechanical properties. While a strong interface tends to provide high strength, a weak interface enables extensive debonding, leading to a high degree of energy absorption. Balancing these conflicting requirements by engineering composite interfaces to improve strength and toughness simultaneously still remains a great challenge. Here, a nanostructured fiber coating was realized to manifest the critical characteristics of natural nacre, at a reduced length scale, consistent with the surface curvature of fibers. The new interphase contains a high proportion (∼90 wt %) of well-aligned inorganic platelets embedded in a polymer; the window of suitable platelet dimensions is very narrow, with an optimized platelet width and thickness of about 130 and 13 nm, respectively. An anisotropic, nanostructured coating was uniformly and conformally deposited onto a large number of 9 μm diameter glass fibers, simultaneously, using self-limiting layer-by-layer assembly (LbL); this parallel approach demonstrates a promising strategy to exploit LbL methods at scale. The resulting nanocomposite interphase, primarily loaded in shear, provides new mechanisms for stress dissipation and plastic deformation. The energy released by fiber breakage in tension appear to spread and dissipate within the nanostructured interphase, accompanied by stable fiber slippage, while the interfacial strength was improved up to 30%.
Analysis of Interface Properties of Hybrid Pre-stressed Strengthening RC Beams with Crack
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xie Zhihong; Huang Peiyan; Guo Yongchang
2010-05-21
A finite element (FE) analysis model of interface layer is established for the pre-stressed CFS-GFS hybrid strengthened beams. An elastic solution for the interfacial stress in the adhesive layer of the retrofitted beams is developed as well. The analytical results were compared with the FE results of interfacial stresses in the beams with different thickness of the adhesive and the fibre sheet. Different heights of Cracks in the interfacial layer of the concrete beam are considered in FE Model. Analysis results show the strengthening pattern is of excellent interface performance and the strength of the fiber sheet can be effectivelymore » utilized. The results also indicate the shear and normal stresses in the interfacial layer of the concrete beam release at the locations of the cracks and reach the maximal value before the concrete cracked. The shear and normal stresses in the adhesive layer increase abruptly, and the cracks in the adhesive layer then appear. The axial stresses of hybrid fiber sheet near the cracks decrease locally at the sites of the concrete cracks.« less
Microfabricated bragg waveguide
Fleming, James G.; Lin, Shawn-Yu; Hadley, G. Ronald
2004-10-19
A microfabricated Bragg waveguide of semiconductor-compatible material having a hollow core and a multilayer dielectric cladding can be fabricated by integrated circuit technologies. The microfabricated Bragg waveguide can comprise a hollow channel waveguide or a hollow fiber. The Bragg fiber can be fabricated by coating a sacrificial mandrel or mold with alternating layers of high- and low-refractive-index dielectric materials and then removing the mandrel or mold to leave a hollow tube with a multilayer dielectric cladding. The Bragg channel waveguide can be fabricated by forming a trench embedded in a substrate and coating the inner wall of the trench with a multilayer dielectric cladding. The thicknesses of the alternating layers can be selected to satisfy the condition for minimum radiation loss of the guided wave.
Optimization, Alternative Materials and Improvements in Body Armor Shields
2007-05-10
performance structures such as protective clothing , bullet-proof vests and helmets due to their high-specific strength and stiffness. The ballistic...regard each layer of the woven composite as made of weft and warp yarns, and divide each yam into 3D solid elements. It is found that the frame...0.25 mm thick layers is modeled as an orthotropic material. Even though the woven composite armor is made of yams and each yarn is made of fibers
Vizzeri, Gianmarco; Bowd, Christopher; Medeiros, Felipe A; Weinreb, Robert N; Zangwill, Linda M
2008-08-01
Misalignment of the Stratus optical coherence tomograph scan circle placed by the operator around the optic nerve head (ONH) during each retinal nerve fiber layer (RNFL) examination can affect the instrument reproducibility and its theoretical ability to detect true structural changes in the RNFL thickness over time. We evaluated the effect of scan circle placement on RNFL measurements. Observational clinical study. Sixteen eyes of 8 normal participants were examined using the Stratus optical coherence tomograph Fast RNFL thickness acquisition protocol (software version 4.0.7; Carl Zeiss Meditec, Dublin, CA). Four consecutive images were taken by the same operator with the circular scan centered on the optic nerve head. Four images each with the scan displaced superiorly, inferiorly, temporally, and nasally were also acquired. Differences in average and sectoral RNFL thicknesses were determined. For the centered scans, the coefficients of variation (CV) and the intraclass correlation coefficient for the average RNFL thickness measured were calculated. When the average RNFL thickness of the centered scans was compared with the average RNFL thickness of the displaced scans individually using analysis of variance with post-hoc analysis, no difference was found between the average RNFL thickness of the nasally (105.2 microm), superiorly (106.2 microm), or inferiorly (104.1 microm) displaced scans and the centered scans (106.4 microm). However, a significant difference (analysis of variance with Dunnett's test: F=8.82, P<0.0001) was found between temporally displaced scans (115.8 microm) and centered scans. Significant differences in sectoral RNFL thickness measurements were found between centered and each displaced scan. The coefficient of variation for average RNFL thickness was 1.75% and intraclass correlation coefficient was 0.95. In normal eyes, average RNFL thickness measurements are robust and similar with significant superior, inferior, and nasal scan displacement, but average RNFL thickness is greater when scans are displaced temporally. Parapapillary scan misalignment produces significant changes in RNFL assessment characterized by an increase in measured RNFL thickness in the quadrant in which the scan is closer to the disc, and a significant decrease in RNFL thickness in the quadrant in which the scan is displaced further from the optic disc.
Diagnostic ability of macular ganglion cell-inner plexiform layer thickness in glaucoma suspects.
Xu, Xiaoyu; Xiao, Hui; Guo, Xinxing; Chen, Xiangxi; Hao, Linlin; Luo, Jingyi; Liu, Xing
2017-12-01
The purpose is to assess the diagnostic ability for early glaucoma of macular ganglion cell-inner plexiform layer (GCIPL) thickness in a Chinese population including glaucoma suspects.A total of 367 eyes with primary open-angle glaucoma (168 early glaucoma, 78 moderate glaucoma, and 121 advanced glaucoma), 52 eyes with ocular hypertension (OHT), 59 eyes with enlarged cup-to-disc ratio (C/D), and 225 normal eyes were included. GCIPL thickness (average, minimum, superotemporal, superior, superonasal, inferonasal, inferior, and inferotemporal), retinal nerve fiber layer (RNFL) thickness, and optic nerve head (ONH) parameters were measured using Cirrus high-definition optical coherence tomography (OCT) and compared. The diagnostic ability of OCT parameters was assessed by area under receiver operating characteristic curve (AUROC) in 3 distinguishing groups: normal eyes and eyes with early glaucoma, normal eyes and eyes with glaucoma regardless of disease stage, and nonglaucomatous eyes (normal eyes, eyes with OHT, and enlarged C/D) and early glaucomatous eyes.Glaucomatous eyes showed a significant reduction in GCIPL thickness compared with nonglaucomatous eyes. In all 3 distinguishing groups, best-performing parameters of GCIPL thickness, RNFL thickness, and ONH parameters were minimum GCIPL thickness (expressed in AUROC, 0.899, 0.952, and 0.900, respectively), average RNFL thickness (0.904, 0.953, and 0.892, respectively), and rim area (0.861, 0.925, and 0.824, respectively). There was no statistical significance of AUROC between minimum GCIPL thickness and average RNFL thickness (all P > .05).GCIPL thickness could discriminate early glaucoma from normal and glaucoma suspects with good sensitivity and specificity. The glaucoma diagnostic ability of GCIPL thickness was comparable to that of RNFL thickness. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.
Effects of Aeroelastic Tailoring on Anisotropic Composite Material Beam Models of Helicopter Blades
1989-05-01
34 means that a layer of material at some distance above a structural midsurface reference location has the identical ply thickness, angular orientation...and material properties as that of a lamina at an identical distance below the midsurface [1]. If the fibers are placed off-axis in the upper and
Automated diagnosis of diabetic retinopathy and glaucoma using fundus and OCT images.
Pachiyappan, Arulmozhivarman; Das, Undurti N; Murthy, Tatavarti Vsp; Tatavarti, Rao
2012-06-13
We describe a system for the automated diagnosis of diabetic retinopathy and glaucoma using fundus and optical coherence tomography (OCT) images. Automatic screening will help the doctors to quickly identify the condition of the patient in a more accurate way. The macular abnormalities caused due to diabetic retinopathy can be detected by applying morphological operations, filters and thresholds on the fundus images of the patient. Early detection of glaucoma is done by estimating the Retinal Nerve Fiber Layer (RNFL) thickness from the OCT images of the patient. The RNFL thickness estimation involves the use of active contours based deformable snake algorithm for segmentation of the anterior and posterior boundaries of the retinal nerve fiber layer. The algorithm was tested on a set of 89 fundus images of which 85 were found to have at least mild retinopathy and OCT images of 31 patients out of which 13 were found to be glaucomatous. The accuracy for optical disk detection is found to be 97.75%. The proposed system therefore is accurate, reliable and robust and can be realized.
Automated diagnosis of diabetic retinopathy and glaucoma using fundus and OCT images
2012-01-01
We describe a system for the automated diagnosis of diabetic retinopathy and glaucoma using fundus and optical coherence tomography (OCT) images. Automatic screening will help the doctors to quickly identify the condition of the patient in a more accurate way. The macular abnormalities caused due to diabetic retinopathy can be detected by applying morphological operations, filters and thresholds on the fundus images of the patient. Early detection of glaucoma is done by estimating the Retinal Nerve Fiber Layer (RNFL) thickness from the OCT images of the patient. The RNFL thickness estimation involves the use of active contours based deformable snake algorithm for segmentation of the anterior and posterior boundaries of the retinal nerve fiber layer. The algorithm was tested on a set of 89 fundus images of which 85 were found to have at least mild retinopathy and OCT images of 31 patients out of which 13 were found to be glaucomatous. The accuracy for optical disk detection is found to be 97.75%. The proposed system therefore is accurate, reliable and robust and can be realized. PMID:22695250
Hömberg, Lisann; Eter, Nicole
2017-01-01
Purpose To compare the structure-function relationships between retinal nerve fiber layer thickness (RNFLT) and visual field defects measured either by standard automated perimetry (SAP) or by Pulsar perimetry (PP). Materials and Methods 263 eyes of 143 patients were prospectively included. Depending on the RNFLT, patients were assigned to the glaucoma group (group A: RNFL score 3–6) or the control group (group B: RNFL score 0–2). Structure-function relationships between RNFLT and mean sensitivity (MS) measured by SAP and PP were analyzed. Results Throughout the entire group, the MS assessed by PP and SAP correlated significantly with RNFLT in all sectors. In the glaucoma group, there was no significant difference between the correlations RNFL-SAP and RNFL-PP, whereas a significant difference was found in the control group. Conclusions In the control group, the correlation between structure and function based on the PP data was significantly stronger than that based on SAP. PMID:29119021
NASA Astrophysics Data System (ADS)
Wang, Zhengduo; Zhang, Li; Liu, Zhongwei; Sang, Lijun; Yang, Lizhen; Chen, Qiang
2017-06-01
In this paper, we report the combination of atomic layer deposition (ALD) with hydrothermal techniques to deposit ZnO on electrospun polyamide 6 (PA 6) nanofiber (NF) surface in the purpose of antibacterial application. The micro- and nanostructures of the hierarchical fibers are characterized by field emission scanning electron microscopy (FE-SEM), high-resolution transmission electron microscopy (HRTEM), and scanning transmission electron microscopy (STEM). We find that NFs can grow into "water lily"- and "caterpillar"-like shapes, which depend on the number of ALD cycles and the hydrothermal reaction period. It is believed that the thickness of ZnO seed layer by ALD process and the period in hydrothermal reaction have the same importance in crystalline growth and hierarchical fiber formation. The tests of antibacterial activity demonstrate that the ZnO/PA 6 core-shell composite fabricated by the combination of ALD with hydrothermal are markedly efficient in suppressing bacteria survivorship.
Structure of the integument of southern right whales, Eubalaena australis.
Reeb, Desray; Best, Peter Barrington; Kidson, Susan Hillary
2007-06-01
Skin (integument) anatomy reflects adaptations to particular environments. It is hypothesized that cetacean (whale) integument will show unique anatomical adaptations to an aquatic environment, particularly regarding differences in temperature, density, and pressure. In this study, the gross and histological structure of the southern right whale integument is described and compared with terrestrial mammals and previous descriptions of mysticete (baleen whale) and odontocete (toothed whale) species. Samples were taken of the integument of 98 free-swimming southern right whales, Eubalaena australis, and examined by both light and electron microscopy. Results show that three epidermal layers are present, with the stratum corneum being parakeratotic in nature. As in bowhead whales, southern right whales possess an acanthotic epidermis and a notably thick hypodermis, with epidermal rods and extensive papillomatosis. However, unlike bowhead whales, southern right whales possess an uninterrupted hypodermal layer. Surprisingly, the integument of balaenids (right and bowhead mysticetes) in general is more like that of odontocetes than that of the more closely related balaenopterids (rorqual mysticetes). Similarities to odontocetes were found specifically in the collagen fibers in a fat-free zone of the reticular dermal layer and the elastic fibers in the dermal and hypodermal layers. Callosities, a distinctive feature of this genus, have a slightly thicker stratum corneum and are usually associated with hairs that have innervated and vascularized follicles. These hairs may function as vibrissae, thus aiding in aquatic foraging by allowing rapid detection of changes in prey density. Although the thick insulatory integument makes right whales bulky and slow-moving, it is an adaptation for living in cold water. Epidermal thickness, presence of epidermal rods, and callosities may act as barriers against mechanical injury from bodily contact with conspecifics or hard surfaces in the environment (e.g., rocks, ice). 2007 Wiley-Liss, Inc.
Kalyani, Partho S.; Holland, Gary N.; Fawzi, Amani A.; Arantes, Tiago E.F.; Yu, Fei; Sadun, Alfredo A.
2014-01-01
Purpose To investigate relationships between contrast sensitivity (CS), color vision, and retinal nerve fiber layer (RNFL) among people with human immunodeficiency virus (HIV) infection; to evaluate the effect of time since diagnosis of HIV infection on RNFL thickness. Design Noninterventional cross-sectional study. Methods We evaluated 102 eyes of 57 HIV-infected individuals without ocular opportunistic infections. Peripapillary RNFL thickness was determined with spectraldomain optical coherence tomography in 4 quadrants. CS was measured with the Pelli-Robson technique (expressed as logCS); color vision was measured with the Lanthony desaturated 15-hue technique (expressed as color confusion index [C-index], with higher scores indicating worse color vision). Correlations between values were assessed using Spearman correlation coefficients. Results Median RNFL thickness (average of 4 quadrants) was 102.9 μm (range, 75.0–134.7 μm). Median logCS was 1.90 (range, 1.25–1.95). Median C-index was 1.58 (range, 0.96–4.07). Temporal RNFL thickness was correlated with logCS (r = 0.295, P = .003) and C-index (r = −0.338, P = .0005). Time since diagnosis of HIV infection was shorter for those with thick average RNFL than for those with thin average RNFL (P = .18). Conclusions Both worse CS and worse color vision are correlated with thinning of the temporal RNFL, with possible threshold effects. Increased prevalences of abnormal CS and abnormal color vision in this population are therefore likely attributable to neuroretinal compromise. This pattern of structural and functional losses may reflect preferential damage to small-caliber axons in the maculopapillary bundle, possibly associated with mitochondrial dysfunction, providing a potential disease mechanism for HIV-associated “neuroretinal disorder.” PMID:22245459
Yu, Ji-Guo; Huang, Qing; Zhou, Xiao-Fang; Ding, Yi; Li, Jing; Xiang, Yi
2018-01-01
To evaluate and compare changes in retinal nerve fiber layer (RNFL) thickness in patients with the pseudoexfoliation syndrome (PXS) and healthy controls. Case-control studies were selected through an electronic search of the Cochrane Controlled Trials Register, PubMed, and Embase. Results were reviewed to ensure that the included studies met prespecified inclusion/exclusion criteria, and the quality of each study was assessed using the Newcastle-Ottawa Scale. All included studies measured average and 4-quadrant (temporal, superior, nasal, and inferior) RNFL thickness using optical coherence tomography (OCT). For the continuous outcomes, we calculated the weighted mean difference (WMD) and 95% confidence intervals (CIs). Eight case-control studies were included in this meta-analysis involving 225 eyes of PXS patients and 208 eyes of healthy controls in total. Statistical analysis revealed that the average RNFL thickness in PXS patients was significantly reduced compared to healthy controls (WMD = -6.91, 95% CI: -9.99 to -3.82, p < 0.0001). Additionally, differences in RNFL thickness in the superior quadrant (WMD = -10.68, 95% CI: -16.40 to -4.95, p = 0.0003), inferior quadrant (WMD = -8.20, 95% CI: -10.85 to -5.55, p < 0.00001), nasal quadrant (WMD = -3.05, 95% CI: -5.21 to -0.90, p = 0.005), and temporal quadrant (WMD = -6.39, 95% CI: -9.98 to -2.80, p = 0.0005) were all significant between the two groups. These results suggest that it is important to evaluate RNFL thickness and the optic nerve head through OCT in patients with PXS in order to determine early glaucomatous damage and start timely intervention prior to visual field loss. © 2017 S. Karger AG, Basel.
Liu, Lin; Zou, Jun; Huang, Hui; Yang, Jian-guo; Chen, Shao-rong
2012-05-23
To evaluate the influence of corneal astigmatism (CA) on retinal nerve fiber layer (RNFL) thickness and optic nerve head(ONH) parameters measured with spectral-domain optical coherence tomography (OCT) in high myopes patients before refractive surgery. Seventy eyes of 35 consecutive refractive surgery candidates were included in this study. The mean age of the subjects was 26.42 ± 6.95 years, the average CA was -1.17 diopters (D; SD 0.64; range -0.2 to-3.3D), All subjects in this study were WTR CA. 34 eyes were in the normal CA group with a mean CA was -0.67 ± 0.28D, 36 eyes were in the high CA group with an average CA of -1.65 ± 0.49D. All subjects underwent ophthalmic examination and imaging with the Cirrus HD OCT. No significant difference was noted in the average cup-to-disk ratio, vertical cup-to-disk ratio and cup volume (all P values > 0.05). Compared with the normal CA group, the high CA group had a larger disc area and rim area, thinner RNFL thickness in the temporal quadrant, and the superotemporal and inferotemporal peaks were farther to the temporal horizon (All P values < 0.05). There were no significant differences between the two groups in global average RNFL thickness, as well as superior, nasal and inferior quadrant RNFL thickness (all P values > 0.05). The degree of with-the-rule CA should be considered when interpreting ONH parameters and peripapillary RNFL thickness measured by the Cirrus HD OCT. The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/1148475676881895.
Klein, Barbara E K; Johnson, Chris A; Meuer, Stacy M; Lee, Kyungmoo; Wahle, Andreas; Lee, Kristine E; Kulkarni, Amruta; Sonka, Milan; Abràmoff, Michael D; Klein, Ronald
2017-04-01
To examine the associations of nerve fiber layer (NFL) thickness with other ocular characteristics in older adults. Participants in the Beaver Dam Eye Study (2008-2010) underwent spectral domain optical coherence tomography (SD-OCT) scans of the optic nerve head, imaging of optic discs, frequency doubling technology (FDT) perimetry, measurement of intraocular pressure (IOP), and an interview concerning their history of glaucoma and use of drops to lower eye pressure. Self-reported histories of glaucoma and the use of drops to lower eye pressure were obtained at follow-up examinations (2014-2016). NFL thickness measured on OCTs varied by location around the optic nerve. Age was associated with mean NFL thickness. Mean NFL was thinnest in eyes with larger cup/disc (C/D) ratios. Horizontal hemifield defects or other optic nerve-field defects were associated with thinner NFL. NFL in persons who reported taking eye drops for high intraocular pressure was thinner compared to those not taking drops. After accounting for the presence of high intraocular pressure, large C/D ratios or hemifield defects, eyes with thinner NFL in the arcades were more likely (OR = 2.3 for 30 micron thinner NFL, p = 0.04) to have incident glaucoma at examination 5 years later. Retinal NFL thickness was associated with a new history of self-reported glaucoma 5 years later. A trial testing the usefulness of NFL as part of a screening battery for predicting glaucoma in those previously undiagnosed might lead to improved case finding and, ultimately, to diminishing the risk of visual field loss.
Gao, LiYan; Liu, Ying; Li, XiaoHong; Bai, QuanHao; Liu, Ping
2015-01-01
We investigated possible abnormalities in the retinal nerve fiber layer (RNFL) and macula lutea of patients diagnosed with Alzheimer's disease (AD) and mild cognitive impairment (MCI) and tested for any correlation with the severity of dementia. A total of 72 subjects, comprising 25 AD patients, 26 MCI patients and 21 healthy individuals (controls) were enrolled in this study. The thickness of the RNFL and volume of the macula lutea was determined using optical coherence tomography (OCT). When compared with controls, we found statistically significant thinning of the RNFL in AD patients at all clock-hour positions except 12:00, and nasal quadrant, 2:00, 3:00 and 4:00. After adjusting several risk factors, the average thickness of the RNFL was reduced in MCI patients compared to AD patients, with specific reductions at inferior quadrant, 5:00 and 6:00. Compared to controls, MCI patients showed a significant decrease in RNFL thickness only in the temporal quadrant, 8:00, 9:00 and 10:00. We found significant reduction in the volume of the macula lutea both in AD and MCI patients. Finally, we could not establish any correlation between patient Mini-Mental State Examination (MMSE) scores (an estimation of the severity of cognitive impairment) and any OCT parameter. Retinal degeneration in AD and MCI patients results in decreased thickness of the RNFL, and reduced macular volume in AD and MCI patients. However, there seems to be no correlation between these changes and the severity of dementia. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Tatham, Andrew J; Boer, Erwin R; Rosen, Peter N; Della Penna, Mauro; Meira-Freitas, Daniel; Weinreb, Robert N; Zangwill, Linda M; Medeiros, Felipe A
2014-11-01
To examine the relationship between glaucomatous structural damage and ability to divide attention during simulated driving. Cross-sectional observational study. Hamilton Glaucoma Center, University of California San Diego. Total of 158 subjects from the Diagnostic Innovations in Glaucoma Study, including 82 with glaucoma and 76 similarly aged controls. Ability to divide attention was investigated by measuring reaction times to peripheral stimuli (at low, medium, or high contrast) while concomitantly performing a central driving task (car following or curve negotiation). All subjects had standard automated perimetry (SAP) and optical coherence tomography was used to measure retinal nerve fiber layer (RNFL) thickness. Cognitive ability was assessed using the Montreal Cognitive Assessment and subjects completed a driving history questionnaire. Reaction times to the driving simulator divided attention task. The mean reaction times to the low-contrast stimulus were 1.05 s and 0.64 s in glaucoma and controls, respectively, during curve negotiation (P < .001), and 1.19 s and 0.77 s (P = .025), respectively, during car following. There was a nonlinear relationship between reaction times and RNFL thickness in the better eye. RNFL thickness remained significantly associated with reaction times even after adjusting for age, SAP mean deviation in the better eye, cognitive ability, and central driving task performance. Although worse SAP sensitivity was associated with worse ability to divide attention, RNFL thickness measurements provided additional information. Information from structural tests may improve our ability to determine which patients are likely to have problems performing daily activities, such as driving. Copyright © 2014 Elsevier Inc. All rights reserved.
Retinal Tissue Thickness is Reduced in Diabetic Peripheral Neuropathy.
Srinivasan, Sangeetha; Pritchard, Nicola; Vagenas, Dimitrios; Edwards, Katie; Sampson, Geoff P; Russell, Anthony W; Malik, Rayaz A; Efron, Nathan
2016-10-01
To investigate the relationship between diabetic peripheral neuropathy (DPN) and retinal tissue thickness. Full retinal thickness in the central retinal, parafoveal, and perifoveal zones and thickness of the ganglion cell complex and retinal nerve fiber layer (RNFL) were assessed in 193 individuals (84 with type 1 diabetes, 67 with type 2 diabetes, and 42 healthy controls) using spectral domain optical coherence tomography. Among those with diabetes, 44 had neuropathy defined using a modified neuropathy disability score recorded on a 0-10 scale. Multiple regression analysis was performed to investigate the relationship between diabetic neuropathy and retinal tissue thickness, adjusted for the presence of diabetic retinopathy (DR), age, sex, duration of diabetes, and HbA 1c levels. In individuals with diabetes, perifoveal thickness was inversely related to the severity of neuropathy (p < 0.05), when adjusted for age, sex, duration of diabetes, and HbA 1c levels. DR was associated with reduced thickness in parafovea (p < 0.01). The RNFL was thinner in individuals with greater degrees of neuropathy (p < 0.04). DPN is associated with structural compromise involving several retinal layers. This compromise may represent a threat to visual integrity and therefore warrants examination of functional correlates.
Benedikovic, Daniel; Alonso-Ramos, Carlos; Cheben, Pavel; Schmid, Jens H; Wang, Shurui; Xu, Dan-Xia; Lapointe, Jean; Janz, Siegfried; Halir, Robert; Ortega-Moñux, Alejandro; Wangüemert-Pérez, J Gonzalo; Molina-Fernández, Iñigo; Fédéli, Jean-Marc; Vivien, Laurent; Dado, Milan
2015-09-15
We present the first experimental demonstration of a new fiber-chip grating coupler concept that exploits the blazing effect by interleaving the standard full (220 nm) and shallow etch (70 nm) trenches in a 220 nm thick silicon layer. The high directionality is obtained by controlling the separation between the deep and shallow trenches to achieve constructive interference in the upward direction and destructive interference toward the silicon substrate. Utilizing this concept, the grating directionality can be maximized independent of the bottom oxide thickness. The coupler also includes a subwavelength-engineered index-matching region, designed to reduce the reflectivity at the interface between the injection waveguide and the grating. We report a measured fiber-chip coupling efficiency of -1.3 dB, the highest coupling efficiency achieved to date for a surface grating coupler in a 220 nm silicon-on-insulator platform fabricated in a conventional dual-etch process without high-index overlays or bottom mirrors.
Foveomacular schisis in juvenile X-linked retinoschisis: an optical coherence tomography study.
Yu, Jia; Ni, Yingqin; Keane, Pearse A; Jiang, Chunhui; Wang, Wenji; Xu, Gezhi
2010-06-01
To explore the structural features of juvenile X-linked retinoschisis using spectral-domain optical coherence tomography (OCT). Retrospective, observational cross-sectional study. Eighteen male patients (34 eyes) who were diagnosed with juvenile X-linked retinoschisis at the Eye & ENT Hospital of Fudan University over an 18-month period were included. Their OCT images, which were obtained using spectral-domain OCT (Cirrus HD-OCT; Carl Zeiss Meditec), were analyzed. The anatomic location of the schisis cavity in juvenile X-linked retinoschisis was characterized by direct inspection of OCT images. On OCT, the schisis cavity was visible at the fovea in all 34 eyes, and it was associated with increased retinal thickness. Schisis was present at the retinal nerve fiber layer in 4 eyes, at the inner nuclear layer in 29 eyes, and at the outer nuclear layer/outer plexiform layer in 22 eyes. In most cases, widespread foveomacular schisis was detected using OCT; however, in 9 eyes (6 patients), the schisis was confined to the fovea. Schisis of the inner nuclear layer and outer nuclear layer/outer plexiform layer almost always involved the foveal center, but retinal nerve fiber layer schisis was seen only in the parafoveal area. Despite conventional wisdom, in patients with X-linked retinoschisis, the schisis cavity can occur in a number of different layers of the neurosensory retina (retinal nerve fiber layer, inner nuclear layer, and outer nuclear layer/outer plexiform layer). In addition, different forms of schisis may affect different locations in the macula (foveal vs parafoveal), and, in most eyes, the schisis involves the entire foveomacular region. Copyright 2010 Elsevier Inc. All rights reserved.
Goh, Jody P; Koh, Victor; Chan, Yiong Huak; Ngo, Cheryl
2017-07-01
To study the distribution of macular ganglion cell-inner plexiform layer (GC-IPL) thickness and peripapillary retinal nerve fiber layer (RNFL) thickness in children with refractive errors. Two hundred forty-three healthy eyes from 139 children with refractive error ranging from -10.00 to +5.00 D were recruited from the National University Hospital Eye Surgery outpatient clinic. After a comprehensive ocular examination, refraction, and axial length (AL) measurement (IOLMaster), macular GC-IPL and RNFL thickness values were obtained with a spectral domain Cirrus high definition optical coherence tomography system (Carl Zeiss Meditec Inc.). Only scans with signal strength of >6/10 were included. Correlation between variables was calculated using the Pearson correlation coefficient. A multivariate analysis using mixed models was done to adjust for confounders. The mean spherical equivalent refraction was -3.20±3.51 D and mean AL was 24.39±1.72 mm. Average, minimum, superior, and inferior GC-IPL were 82.59±6.29, 77.17±9.65, 83.68±6.96, and 81.64±6.70 μm, respectively. Average, superior, and inferior peripapillary RNFL were 99.00±11.45, 123.20±25.81, and 124.24±22.23 μm, respectively. Average, superior, and inferior GC-IPL were correlated with AL (β=-2.056, P-value 0.000; β=-2.383, P-value 0.000; β=-1.721, P-value 0.000), but minimum GC-IPL was not (β=-1.056, P-value 0.115). None of the RNFL parameters were correlated with AL. This study establishes normative macular GC-IPL and RNFL thickness in children with refractive errors. Our results suggest that high definition optical coherence tomography RNFL parameters and minimum GC-IPL are not affected by AL or myopia in children, and therefore warrants further evaluation in pediatric glaucoma patients.
Glaucoma diagnosis by mapping macula with Fourier domain optical coherence tomography
NASA Astrophysics Data System (ADS)
Tan, Ou; Lu, Ake; Chopra, Vik; Varma, Rohit; Hiroshi, Ishikawa; Schuman, Joel; Huang, David
2008-03-01
A new image segmentation method was developed to detect macular retinal sub-layers boundary on newly-developed Fourier-Domain Optical Coherence Tomography (FD-OCT) with macular grid scan pattern. The segmentation results were used to create thickness map of macular ganglion cell complex (GCC), which contains the ganglion cell dendrites, cell bodies and axons. Overall average and several pattern analysis parameters were defined on the GCC thickness map and compared for the diagnosis of glaucoma. Intraclass correlation (ICC) is used to compare the reproducibility of the parameters. Area under receiving operative characteristic curve (AROC) was calculated to compare the diagnostic power. The result is also compared to the output of clinical time-domain OCT (TD-OCT). We found that GCC based parameters had good repeatability and comparable diagnostic power with circumpapillary nerve fiber layer (cpNFL) thickness. Parameters based on pattern analysis can increase the diagnostic power of GCC macular mapping.
Tensile Strength and Microstructural Characterization of Uncoated and Coated HPZ Ceramic Fibers
NASA Technical Reports Server (NTRS)
Bansal, Narottam P.; Wheeler, Donald R.; Dickerson, Robert M.
1996-01-01
Tensile strengths of as-received HPZ fiber and those surface coated with BN, BN/SiC, and BN/Si3N4 have been determined at room temperature using a two-parameter Weibull distribution. Nominally approx. 0.4 micron BN and 0.2 micron SiC or Si3N4 coatings were deposited on the fibers by chemical vapor deposition using a continuous reactor. The average tensile strength of uncoated HPZ fiber was 2.0 +/- 0.56 GPa (290 +/- 81 ksi) with a Weibull modulus of 4.1. For the BN coated fibers, the average strength and the Weibull modulus increased to 2.39 +/- 0.44 GPa (346 +/- 64 ksi) and 6.5, respectively. The HPZ/BN/SiC fibers showed an average strength of 2.0 +/- 0.32 GPa (290 +/- 47 ksi) and Weibull modulus of 7.3. Average strength of the fibers having a dual BN/Si3N4 surface coating degraded to 1.15 +/- 0.26 GPa (166 +/- 38 ksi) with a Weibull modulus of 5.3. The chemical composition and thickness of the fiber coatings were determined using scanning Auger analysis. Microstructural analysis of the fibers and the coatings was carried out by scanning electron microscopy and transmission electron microscopy. A microporous silica-rich layer approx. 200 nm thick is present on the as-received HPZ fiber surface. The BN coatings on the fibers are amorphous to partly turbostratic and contaminated with carbon and oxygen. Silicon carbide coating was crystalline whereas the silicon nitride coating was amorphous. The silicon carbide and silicon nitride coatings are non-stoichiometric, non-uniform, and granular. Within a fiber tow, the fibers on the outside had thicker and more granular coatings than those on the inside.
Retina and Nerve Fiber Layer Thickness in Eyes with Thyroid-Associated Ophthalmopathy.
Blum Meirovitch, Sharon; Leibovitch, Igal; Kesler, Anat; Varssano, David; Rosenblatt, Amir; Neudorfer, Meira
2017-05-01
Thyroid-associated ophthalmopathy (TAO) is an inflammatory disease that affects the thyroid gland and the eye orbit. Of patients with TAO, 3%-5% have severe sight-threatening disease due to optic neuropathy Optical coherence tomography (OCT), the non-invasive imaging technology that yields high-resolution cross-sectional images of the retina, provides qualitative and quantitative data on the retina. To apply this technique to quantitatively assess retinal nerve fiber layer (RNFL) and macular ring thicknesses in healthy subjects and in patients with TAO to determine their relationship to the severity of the orbital disease. All patients in the ophthalmology clinic who were diagnosed with TAO and underwent OCT imaging as part of their ocular examination comprised the study group, and healthy patients who volunteered to undergo OCT examination served as controls. Results of the complete ophthalmologic examination and OCT findings were collected from medical files, including the thickness of the RNFL and the macula. The study comprised 21 patients and 41 healthy controls. TAO patients exhibited RNFL thickening and inner macula thinning compared to healthy subjects. Mean RNFL thickness was correlated with the severity of the orbital disease. The OCT findings suggest that the retina is involved in TAO, probably as early as the subclinical stage. This highlights the ability of OCT to identify retinal changes earlier and far more accurately than is detected today, enabling earlier diagnosis and more timely treatment to prevent severe visual sequelae.
Ashtari, Fereshteh; Emami, Parisa; Akbari, Mojtaba
2015-01-01
Multiple Sclerosis (MS) is a neurological disease in which demyelination and axonal loss leads to progressive disability. Cognition impairment is among the most common complication. Studying axonal loss in the retina is a new marker for MS. The main goal of our study is to search for correlations between magnetic resonance imaging (MRI) findings and the retinal nerve fiber layer (RNFL) thickness at the macula and head of the optic nerve and Wechsler Adult Intelligence Scale-Revised (WAIS-R) Scores that assess multiple domains of intelligence, and to explore the relationship between changes in the RNFL thickness with intellectual and cognitive dysfunction. A prospective cross-sectional study was conducted at the University Hospital of Kashani, Isfahan, Iran, from September to December 2013. All patients were assessed with a full-scale intelligence quotient (IQ) on the WAIS-R. An optical coherence tomography study and brain MRI were performed in the same week for all the patients. Statistical analysis was conducted by using a bivariate correlation, by utilizing SPSS 20.0. A P value ≤ 0.05 was the threshold of statistical significance. Examination of a 100 patients showed a significant correlation between the average RNFL thickness of the macula and the verbal IQ (P value = 0.01) and full IQ (P value = 0.01). There was a significant correlation between brain atrophy and verbal IQ. The RNFL loss was correlated with verbal IQ and full IQ.
Skopalová, Jana; Barták, Petr; Bednář, Petr; Tomková, Hana; Ingr, Tomáš; Lorencová, Iveta; Kučerová, Pavla; Papoušek, Roman; Borovcová, Lucie; Lemr, Karel
2018-01-25
A carbon fiber brush electrode (CFBE) was newly designed and used as a substrate for both controlled potential electrolysis and atmospheric solids analysis probe (ASAP) mass spectrometry. Electropolymerized and strongly adsorbed products of electrolysis were directly desorbed and ionized from the electrode surface. Electrochemical properties of the electrode investigated by cyclic voltammetry revealed large electroactive surface area (23 ± 3 cm 2 ) at 1.3 cm long array of carbon fibers with diameter 6-9 μm. Some products of electrochemical oxidation of pentabromophenol and 2,4,6-tribromophenol formed a compact layer on the carbon fibers and were analyzed using ASAP. Eleven new oligomeric products were identified including quinones and biphenoquinones. These compounds were not observed previously in electrolyzed solutions by liquid or gas chromatography/mass spectrometry. The thickness around 58 nm and 45 nm of the oxidation products layers deposited on carbon fibers during electrolysis of pentabromophenol and 2,4,6-tribromophenol, respectively, was estimated from atomic force microscopy analysis and confirmed by scanning electron microscopy with energy-dispersive X-ray spectroscopy measurements. Copyright © 2017 Elsevier B.V. All rights reserved.
Srivastav, Khushboo; Mahdi, Abbas A.; Shukla, Rajendra K.; Meyer, Carsten H.; Akduman, Levent; Khanna, Vinay K.
2016-01-01
Purpose To study the correlation between serum levels of vitamin B12, folic acid, and homocysteine and the severity of diabetic retinopathy and the correlation with retinal nerve fiber layer (RNFL) thinning on spectral domain optical coherence tomography (SD-OCT). Methods In a tertiary care center–based prospective cross-sectional study, 60 consecutive cases and 20 healthy controls in the age group of 40–65 years were included. The eyes of the cases were divided into three groups according to Early Treatment Diabetic Retinopathy Study (ETDRS) classification: diabetes mellitus without retinopathy (n = 20), non-proliferative diabetic retinopathy with macular edema (n = 20), and proliferative diabetic retinopathy with macular edema (n = 20). The serum levels of vitamin B12 and folic acid were measured using a standard protocol. The serum homocysteine assay was performed using an enzyme-linked immunosorbent assay (ELISA) kit. Average RNFL thickness was measured using SD-OCT. Statistical analysis was used to assess the correlations between the study variables. Results Increased severity of diabetic retinopathy was found to correlate with an increase in the serum levels of homocysteine (F = 53.79; p<0.001). The mean serum levels of vitamin B12 and folic acid were found to be within the normal reference range. A positive correlation was found between retinal nerve fiber layer thinning and serum levels of homocysteine (p<0.001). Conclusions This study, for the first time, demonstrated a correlation between increased homocysteine with a decrease in RNFL thickness and increased severity of diabetic retinopathy. PMID:27994434
NASA Technical Reports Server (NTRS)
Cho, Y. C.; George, Thomas; Norvig, Peter (Technical Monitor)
1999-01-01
Research into advanced pressure sensors using fiber-optic technology is aimed at developing compact size microphones. Fiber optic sensors are inherently immune to electromagnetic noise, and are very sensitive, light weight, and highly flexible. In FY 98, NASA researchers successfully designed and assembled a prototype fiber-optic microphone. The sensing technique employed was fiber optic Fabry-Perot interferometry. The sensing head is composed of an optical fiber terminated in a miniature ferrule with a thin, silicon-microfabricated diaphragm mounted on it. The optical fiber is a single mode fiber with a core diameter of 8 micron, with the cleaved end positioned 50 micron from the diaphragm surface. The diaphragm is made up of a 0.2 micron thick silicon nitride membrane whose inner surface is metallized with layers of 30 nm titanium, 30 nm platinum, and 0.2 micron gold for efficient reflection. The active sensing area is approximately 1.5 mm in diameter. The measured differential pressure tolerance of this diaphragm is more than 1 bar, yielding a dynamic range of more than 100 dB.
Chien, Jason L; Ghassibi, Mark P; Patthanathamrongkasem, Thipnapa; Abumasmah, Ramiz; Rosman, Michael S; Skaat, Alon; Tello, Celso; Liebmann, Jeffrey M; Ritch, Robert; Park, Sung Chul
2017-03-01
To compare glaucoma diagnostic capability of global/regional macular layer parameters in different-sized grids. Serial horizontal spectral-domain optical coherence tomography scans of macula were obtained. Automated macular grids with diameters of 3, 3.45, and 6 mm were used. For each grid, 10 parameters (total volume; average thicknesses in 9 regions) were obtained for 5 layers: macular retinal nerve fiber layer (mRNFL), ganglion cell layer (GCL), inner plexiform layer (IPL), ganglion cell-inner plexiform layer (GCIPL; GCL+IPL), and ganglion cell complex (GCC; mRNFL+GCL+IPL). Sixty-nine normal eyes (69 subjects) and 87 glaucomatous eyes (87 patients) were included. For the total volume parameter, the area under the receiver operating characteristic curves (AUCs) in 6-mm grid were larger than the AUCs in 3- and 3.45-mm grids for GCL, GCC, GCIPL, and mRNFL (all P<0.020). For the average thickness parameters, the best AUC in 6-mm grid (T2 region for GCL, IPL, and GCIPL; I2 region for mRNFL and GCC) was greater than the best AUC in 3-mm grid for GCL, GCC, and mRNFL (P<0.045). The AUC of GCL volume (0.920) was similar to those of GCC (0.920) and GCIPL (0.909) volume. The AUC of GCL T2 region thickness (0.942) was similar to those of GCC I2 region (0.942) and GCIPL T2 region (0.934) thickness. Isolated macular GCL appears to be as good as GCC and GCIPL in glaucoma diagnosis, while IPL does not. Larger macular grids may be better at detecting glaucoma. Each layer has a characteristic region with the best glaucoma diagnostic capability.
NASA Astrophysics Data System (ADS)
Ke, Xinyou; Alexander, J. Iwan D.; Prahl, Joseph M.; Savinell, Robert F.
2015-08-01
A simple analytical model of a layered system comprised of a single passage of a serpentine flow channel and a parallel underlying porous electrode (or porous layer) is proposed. This analytical model is derived from Navier-Stokes motion in the flow channel and Darcy-Brinkman model in the porous layer. The continuities of flow velocity and normal stress are applied at the interface between the flow channel and the porous layer. The effects of the inlet volumetric flow rate, thickness of the flow channel and thickness of a typical carbon fiber paper porous layer on the volumetric flow rate within this porous layer are studied. The maximum current density based on the electrolyte volumetric flow rate is predicted, and found to be consistent with reported numerical simulation. It is found that, for a mean inlet flow velocity of 33.3 cm s-1, the analytical maximum current density is estimated to be 377 mA cm-2, which compares favorably with experimental result reported by others of ∼400 mA cm-2.
Structural investigations of human hairs by spectrally resolved ellipsometry
NASA Astrophysics Data System (ADS)
Schulz, Benjamin; Chan, D.; Ruebhausen, M.; Wessel, S.; Wepf, R.
2006-03-01
Human hair is a biological layered system composed of two major layers, the cortex and the cuticle. We show spectrally resolved ellipsometry measurements of the ellipsometric parameters ψ and δ of single human hairs. The spectra reflect the layered nature of hair and the optical anisotropy of the hair’s structure. In addition, measurements on strands of human hair show a high reproducibility of the ellipsometric parameters for different hair fiber bundles from the same person. Based on the measurements, we develop a model of the dielectric function of hair that explains the spectra. This model includes the dielectric properties of the cuticle and cortex as well as their associated layer thicknesses. In addition, surface roughness effects modelled by a roughness layer with an complex refractive index given by an effective medium approach can have a significant effect on the measurements. We derive values for the parameters of the cuticle surface roughness layer of the thickness dACu= 273-360 nm and the air inclusion fA= 0.6 -5.7%. [1] accepted for publication in J. Biomed Opt., 2005
Zhu, Shan; Pang, Fufei; Huang, Sujuan; Zou, Fang; Dong, Yanhua; Wang, Tingyun
2015-06-01
Atomic layer deposition (ALD) technology is introduced to fabricate a high sensitivity refractive index sensor based on an adiabatic tapered optical fiber. Different thickness of Al2O3 nanofilm is coated around fiber taper precisely and uniformly under different deposition cycles. Attributed to the high refractive index of the Al2O3 nanofilm, an asymmetry Fabry-Perot like interferometer is constructed along the fiber taper. Based on the ray-optic analysis, total internal reflection happens on the nanofilm-surrounding interface. With the ambient refractive index changing, the phase delay induced by the Goos-Hänchen shift is changed. Correspondingly, the transmission resonant spectrum shifts, which can be utilized for realizing high sensitivity sensor. The high sensitivity sensor with 6008 nm/RIU is demonstrated by depositing 3000 layers Al2O3 nanofilm as the ambient refractive index is close to 1.33. This high sensitivity refractive index sensor is expected to have wide applications in biochemical sensors.
Tak, Ali Zeynel Abidin; Sengul, Yıldızhan; Bilak, Şemsettin
2018-03-01
The aim of our study is to assess retinal nerve fiber layer (RNFL), the ganglion cell layer (GCL), inner-plexiform layer (IPL), and choroidal layer in migraine patients with white matter lesion (WML) or without WML, using spectral domain optical coherence tomography (OCT). To our study, 77 migraine patients who are diagnosed with migraine in accordance to the International Classification of Headache Disorders (ICHD)-3 beta and 43 healthy control are included. In accordance to cranial MRI, migraine patients are divided into two groups as those who have white matter lesions (39 patients), and those who do not have a lesion (38 patients). OCT was performed for participants. The average age of participants was comparable. The RNFL average thickness parameter in the migraine group was significantly lower than in the control group (p < 0.01). However, no significant difference was detected among those migraine patients who have WML, and those who do not have. No significant difference is detected among all groups in terms of IPL, GCL, and choroidal layer measuring scales. The proofs showing that affected retinal nerve fiber layer are increased in migraine patients. However, it is not known whether this may affect other layers of retina, or whether there is a correlation between affected retinal structures and white matter lesions. In our study, we found thinner RNFL in migraine patients when we compared with controls but IPL, GCL, and choroid layer values were similar between each patient groups and controls. Also, all parameters were similar between patients with WML and without WML. Studies in this regard are required.
Large-scale, thick, self-assembled, nacre-mimetic brick-walls as fire barrier coatings on textiles
Das, Paramita; Thomas, Helga; Moeller, Martin; Walther, Andreas
2017-01-01
Highly loaded polymer/clay nanocomposites with layered structures are emerging as robust fire retardant surface coatings. However, time-intensive sequential deposition processes, e.g. layer-by-layer strategies, hinders obtaining large coating thicknesses and complicates an implementation into existing technologies. Here, we demonstrate a single-step, water-borne approach to prepare thick, self-assembling, hybrid fire barrier coatings of sodium carboxymethyl cellulose (CMC)/montmorillonite (MTM) with well-defined, bioinspired brick-wall nanostructure, and showcase their application on textile. The coating thickness on the textile is tailored using different concentrations of CMC/MTM (1–5 wt%) in the coating bath. While lower concentrations impart conformal coatings of fibers, thicker continuous coatings are obtained on the textile surface from highest concentration. Comprehensive fire barrier and fire retardancy tests elucidate the increasing fire barrier and retardancy properties with increasing coating thickness. The materials are free of halogen and heavy metal atoms, and are sourced from sustainable and partly even renewable building blocks. We further introduce an amphiphobic surface modification on the coating to impart oil and water repellency, as well as self-cleaning features. Hence, our study presents a generic, environmentally friendly, scalable, and one-pot coating approach that can be introduced into existing technologies to prepare bioinspired, thick, fire barrier nanocomposite coatings on diverse surfaces. PMID:28054589
Fiber optic interferometry for industrial process monitoring and control applications
NASA Astrophysics Data System (ADS)
Marcus, Michael A.
2002-02-01
Over the past few years we have been developing applications for a high-resolution (sub-micron accuracy) fiber optic coupled dual Michelson interferometer-based instrument. It is being utilized in a variety of applications including monitoring liquid layer thickness uniformity on coating hoppers, film base thickness uniformity measurement, digital camera focus assessment, optical cell path length assessment and imager and wafer surface profile mapping. The instrument includes both coherent and non-coherent light sources, custom application dependent optical probes and sample interfaces, a Michelson interferometer, custom electronics, a Pentium-based PC with data acquisition cards and LabWindows CVI or LabView based application specific software. This paper describes the development evolution of this instrument platform and applications highlighting robust instrument design, hardware, software, and user interfaces development. The talk concludes with a discussion of a new high-speed instrument configuration, which can be utilized for high speed surface profiling and as an on-line web thickness gauge.
Lubrication theory for a random fibrous medium
NASA Astrophysics Data System (ADS)
Mirbod, Parisa; Andreopoulos, Yiannis; Weinbaum, Sheldon
2007-11-01
In the classical theory for a slipper bearing one examines the relative motion of an inclined planar surface and a horizontal planar surface. The solution for the pressure distribution and lift force are independent of which boundary is moving and there is an optimum tilt k=h1/h2=2.2 for maximum lift. This symmetry is lost if the intervening space is filled with a soft porous fibrous material. In this paper the generalized Reynolds equation derived in Feng and Weinbaum (2000) J. Fluid Mech. 422:281 is extended to treat a random fiber matrix satisfying the widely used Carman-Kozeny equation. We show that the solutions are strikingly different depending on whether a) the inclined upper boundary moves or b) the upper boundary is stationary and the horizontal lower boundary moves beneath it. The behavior depends critically on the value of the dimensionless fiber interaction layer thickness α=H/√Kp . In a) the pressure and lift force increase as 2̂ and asymptotically approach a limiting behavior for large values of α since the fluid is pushed forward by the tilt of the upper boundary. In b) the pressure and lift force decay as &-2circ; since the fiber interaction layer thickness decreases and the amount of fluid dragged though the fluid gap decreases as α increases and vanishes for α>> 1.
Stiff, Strong Splice For A Composite Sandwich Structure
NASA Technical Reports Server (NTRS)
Schmaling, D.
1991-01-01
New type of splice for composite sandwich structure reduces peak shear stress in structure. Layers of alternating fiber orientation interposed between thin ears in adhesive joint. Developed for structural joint in spar of helicopter rotor blade, increases precision of control over thickness of adhesive at joint. Joint easy to make, requires no additional pieces, and adds little weight.
Otin, Sofia; Fuertes, Maria I.; Vilades, Elisa; Gracia, Hector; Ara, Jose R.; Alarcia, Raquel; Polo, Vicente; Larrosa, Jose M.; Pablo, Luis E.
2016-01-01
Neurodegenerative diseases present a current challenge for accurate diagnosis and for providing precise prognostic information. Developing imaging biomarkers for multiple sclerosis (MS), Parkinson disease (PD), and Alzheimer's disease (AD) will improve the clinical management of these patients and may be useful for monitoring treatment effectiveness. Recent research using optical coherence tomography (OCT) has demonstrated that parameters provided by this technology may be used as potential biomarkers for MS, PD, and AD. Retinal thinning has been observed in these patients and new segmentation software for the analysis of the different retinal layers may provide accurate information on disease progression and prognosis. In this review we analyze the application of retinal evaluation using OCT technology to provide better understanding of the possible role of the retinal layers thickness as biomarker for the detection of these neurodegenerative pathologies. Current OCT analysis of the retinal nerve fiber layer and, specially, the ganglion cell layer thickness may be considered as a good biomarker for disease diagnosis, severity, and progression. PMID:27840739
High-sensitivity four-layer polymer fiber-optic evanescent wave sensor.
Xin, Xin; Zhong, Nianbing; Liao, Qiang; Cen, Yanyan; Wu, Ruohua; Wang, Zhengkun
2017-05-15
We present a novel four-layer structure consisting of bottom, second, third, and surface layers in the sensing region, for a D-shaped step-index fiber-optic evanescent wave (FOEW) sensor. To reduce the background noise, the surface of the longitudinal section in the D-shaped region is coated with a light-absorbing film. We check the morphologies of the second and surface layers, examine the refractive indices (RIs) of the third and surface layers, and analyze the composition of the surface layer. We also investigate the effects of the thicknesses and RIs of the third and surface layers and the LA film on the light transmission and sensitivity of the FOEW sensors. The results highlight the very good sensitivity of the proposed FOEW sensor with a four-layer structure, which reached -0.077 (μg/l) -1 in the detection of the target antibody; the sensitivity of the novel FOEW sensor was 7.60 and 1.52 times better than that of a conventional sensor with a core-cladding structure and an FOEW sensor with a three-layer structure doped with GeO 2 . The applications of this high-sensitivity FOEW sensor can be extended to biodefense, disease diagnosis, and biomedical and biochemical analysis. Copyright © 2017 Elsevier B.V. All rights reserved.
Sarfraz, Muhammad Haroon; Mehboob, Mohammad Asim; Haq, Rana Intisar Ul
2017-01-01
To evaluate the correlation between Central Corneal Thickness (CCT) and Visual Field (VF) defect parameters like Mean Deviation (MD) and Pattern Standard Deviation (PSD), Cup-to-Disc Ratio (CDR) and Retinal Nerve Fibre Layer Thickness (RNFL-T) in Primary Open-Angle Glaucoma (POAG) patients. This cross sectional study was conducted at Armed Forces Institute of Ophthalmology (AFIO), Rawalpindi from September 2015 to September 2016. Sixty eyes of 30 patients with diagnosed POAG were analysed. Correlation of CCT with other variables was studied. Mean age of study population was 43.13±7.54 years. Out of 30 patients, 19 (63.33%) were males and 11 (36.67%) were females. Mean CCT, MD, PSD, CDR and RNFL-T of study population was 528.57±25.47µm, -9.11±3.07, 6.93±2.73, 0.63±0.13 and 77.79±10.44µm respectively. There was significant correlation of CCT with MD, PSD and CDR (r=-0.52, p<0.001; r=-0.59, p<0.001;r=-0.41, p=0.001 respectively). The correlation of CCT with RNFL-T was not statistically significant (r=-0.14, p=0.284). Central corneal thickness had significant correlation with visual field parameters like mean deviation and pattern standard deviation, as well as with cup-to-disc ratio. However, central corneal thickness had no significant relationship with retinal nerve fibre layer thickness.
Mukherjee, Dibyendu; Stinnett, Sandra S.; Cousins, Scott W.; Potter, Guy G.; Burke, James R.; Farsiu, Sina; Whitson, Heather E.
2018-01-01
Inner retina in Alzheimer's Disease (AD) may experience neuroinflammation resulting in atrophy. The objective of our study was to determine whether retinal GCIPL (ganglion cell-inner plexiform layer) or nerve fiber layer (NFL) thickness may serve as noninvasive biomarkers to diagnose AD. This cross-sectional case-control study enrolled 15 mild cognitive impairment (MCI) patients, 15 mild-moderate AD patients, and 18 cognitively normal adults. NFL and GCIPL thicknesses on optical coherence tomography (OCT) were measured using Duke Optical Coherence Tomography Retinal Analysis Program (DOCTRAP) and Spectralis software. We demonstrated that regional thicknesses of NFL or GCIPL on macular or nerve OCTs did not differ between groups. However, a multi-variate regression analysis identified macular areas with a significant thickening or thinning in NFL and GCIPL in MCI and AD patients. Our primary findings controvert previous reports of thinner NFL in moderate-to-severe AD. The areas of thickening of GCIPL and NFL in the macula adjacent to areas of thinning, as revealed by a more complex statistical model, suggest that NFL and GCIPL may undergo dynamic changes during AD progression. PMID:29420642
NASA Technical Reports Server (NTRS)
Xiao, Yegao; Bhat, Ishwara; Abedin, M. Nurul
2005-01-01
InP/InGaAs avalanche photodiodes (APDs) are being widely utilized in optical receivers for modern long haul and high bit-rate optical fiber communication systems. The separate absorption, grading, charge, and multiplication (SAGCM) structure is an important design consideration for APDs with high performance characteristics. Time domain modeling techniques have been previously developed to provide better understanding and optimize design issues by saving time and cost for the APD research and development. In this work, performance dependences on multiplication layer thickness have been investigated by time domain modeling. These performance characteristics include breakdown field and breakdown voltage, multiplication gain, excess noise factor, frequency response and bandwidth etc. The simulations are performed versus various multiplication layer thicknesses with certain fixed values for the areal charge sheet density whereas the values for the other structure and material parameters are kept unchanged. The frequency response is obtained from the impulse response by fast Fourier transformation. The modeling results are presented and discussed, and design considerations, especially for high speed operation at 10 Gbit/s, are further analyzed.
Postnatal development of retinal projections in the brushtailed possum, Trichosurus vulpecula.
Sanderson, K J; Dixon, P G; Pearson, L J
1982-10-01
The postnatal development of retinal projections was studied in the brushtailed possum, Trichosurus vulpecula. [3H]proline was injected into one eye of 13 young possums aged 24-84 days in order to trace retinal pathways. The dorsal lateral geniculate nucleus (LGNd) can be identified in Nissl material at 19 days but not at 9-10 days. By 40 days some cytoarchitectural lamination of the LGNd is apparent and by 71 days the adult pattern of cell layers is present. At 24 days retinal fibers occupy by lateral part of the LGNd on both sides of the brain. By 38-40 days the retinal fibers fill be contralateral LGNd and the binocular part of the ipsilateral LGNd and there is a beginning of the segregation of retinal fibers into left and right eye territories. By 49-50 days a partial segregation is achieved, and complete segregation by 71 days. At 9-10 days the superior colliculus is not differentiated into layers and there is a thick zone of cell proliferation around the ventricle. By 23 days the superior colliculus has well-defined cell layers and there is still some indication of cell proliferation around the ventricle. By 40 days, the superior colliculus shows little evidence of cell proliferation. At 24 days retinal fibers fill the superficial layers of the contralateral optic tectum and are lightly distributed through the superficial layers of the rostral half of the ipsilateral tectum. By 38 days the ipsilateral retinal input is restricted to the deeper layers of the tectum. These results show that the adult pattern of retinal projections to the LGNd and optic tectum develops a number of weeks before eye opening occurs (at 90-120 days).
Preparation and characterization of directly compactible layer-by-layer nanocoated cellulose.
Strydom, Schalk J; Otto, Daniel P; Liebenberg, Wilna; Lvov, Yuri M; de Villiers, Melgardt M
2011-02-14
Microcrystalline cellulose is a commonly used direct compression tablet diluent and binder. It is derived from purified α-cellulose in an environmentally unfriendly process that involves mineral acid catalysed hydrolysis. In this study Kraft softwood fibers was nanocoated using a layer-by-layer self-assembling process. Powder flow and compactibility results showed that the application of nano-thin polymer layers on the fibers turned non-flowing, non-compacting cellulose into powders that can be used in the direct compression of tablets. The powder flow properties and tableting indices of compacts compressed from these nanocoated microfibers were similar or better than that of directly compactible microcrystalline cellulose powders. Cellulose microfibers coated with four PSS/PVP bilayers had the best compaction properties while still producing tablets that were able to absorb water and disintegrate and did not retard the dissolution of a model drug acetaminophen. The advantages of nanocoating rather than traditional pharmaceutical coating are that it add less than 1% to the weight of the fibers and allows control of the molecular properties of the surface and the thickness of the coat to within a few nanometers. This process is potentially friendlier to the environment because of the type and quantity of materials used. Also, it does not involve acid-catalyzed hydrolysis and neutralization of depolymerized cellulose. Copyright © 2010 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Mahadi
2018-02-01
Helmets are protective head gears wear by bicycle riders for protection against injury in case of the accident. Helmet standards require helmets to be tested with a simple drop test onto an anvil. The purpose of research is to know toughness of bicycle helmet made from polymeric foam composite strengthened by oil palm empty fruit bunch fiber. This research contains report result manufacture and impacts analysis of bicycle helmet made from polymeric foam composite materials strengthened by oil palm empty fruit bunch fiber (EFB). The geometric helmet structure consists of shell and liner; both layers have sandwich structure. The shell uses matrix unsaturated Polyester BQTN-157EX material, chopped strand mat 300 glass fiber reinforce and methyl ethyl ketone peroxide (MEKPO) catalyst with the weight composition of 100 gr, 15 gr, and 5 gr. The liner uses matrix unsaturated Polyester BQTN-157 EX material, EFB fiber reinforces, Polyurethane blowing agent, and MEKPO catalyst with the composition of 275 gr (50%), 27.5 gr (5%), 247 gr (45%), and 27.5 gr (5%). Layers of the helmet made by using hand lay-up method and gravity casting method. Mechanical properties of polymeric foam were the tensile strength (ơt) 1.17 Mpa, compressive strength (ơc) 0.51 MPa, bending strength (ơb) 3.94 MPa, elasticity modulus (E) 37.97 Mpa, density (ρ) 193 (kg/m3). M4A model helmet is the most ergonomic with the thickness 10 mm and the amount of air channel 11. Free fall impact test was done in 9 samples with the thickness of 10 mm with the height of 1.5 m. The result of the impact test was impacted force (Fi) 241.55 N, Impulse (I) 6.28 Ns, impact Strength (ơi) 2.02 Mpa and impact Energy (Ei) 283.77 Joule. The properties of bicycle helmet model BMX-M4A type was 264 mm length, 184 mm width, 154 mm height, 10 mm thick, 580 mm head circle, 331 g mass and 11 wind channels.
FIBER AND INTEGRATED OPTICS: Optimization of optical film waveguides
NASA Astrophysics Data System (ADS)
Adamson, P. V.
1990-10-01
Theoretical investigations were made of the possibility of optimization of the effective thickness, of the optical confinement factor Γ1, and of the birefringence of a planar dielectric waveguide as a function of the waveguide parameter V and the waveguide asymmetry. For a given value of V it is possible to ensure higher values of Γ1, for an asymmetric waveguide than for a symmetric one. An approximate expression is proposed for the factor Γ1, of an asymmetric waveguide directly in terms of its thickness and the refractive indices of the layers.
Highly stretchable and conductive fibers enabled by liquid metal dip-coating
NASA Astrophysics Data System (ADS)
Zhang, Qiang; Roach, Devin J.; Geng, Luchao; Chen, Haosen; Qi, H. Jerry; Fang, Daining
2018-03-01
Highly stretchable and conductive fibers have been fabricated by dip-coating of a layer of liquid metal (eutectic gallium indium, EGaIn) on printed silicone elastomer filaments. This fabrication method exploits a nanolayer of oxide skin that rapidly forms on the surface of EGaIn when exposed to air. Through dip-coating, the sticky nature of the oxide skin leads to the formation of a thin EGaIn coating (˜5 μm thick) on the originally nonconductive filaments and renders these fibers excellent conductivity. Electrical characterization shows that the fiber resistance increases moderately as the fiber elongates but always maintains conductivity even when stretched by 800%. Besides this, these fibers possess good cyclic electrical stability with little degradation after hundreds of stretching cycles, which makes them an excellent candidate for stretchable conductors. We then demonstrate a highly stretchable LED circuit as well as a conductive stretchable net that extends the 1D fibers into a 2D configuration. These examples demonstrate potential applications for topologically complex stretchable electronics.
NASA Astrophysics Data System (ADS)
Oshikane, Yasushi; Murai, Kensuke; Nakano, Motohiro
2013-09-01
We have been studied a finite asymmetric metal-insulator-metal (MIM) structure on glass plate for near-future visible light communication (VLC) system with white LED illuminations in the living space (DOI: 10.1117/12.929201). The metal layers are vacuum-evaporated thin silver (Ag) films (around 50 nm and 200 nm, respectively), and the insulator layer (around 150 nm) is composed of magnesium fluoride (MgF2). A characteristic narrow band filtering of the MIM structure at visible region might cause a confinement of intense surface plasmon polaritons (SPPs) at specific monochromatic frequency inside a subwavelength insulator layer of the MIM structure. Central wavelength and depth of such absorption dip in flat spectral reflectance curve is controlled by changing thicknesses of both insulator and thinner metal layers. On the other hand, we have proposed a twin-hole pass-through wave guide for SPPs in thick Ag film (DOI: 10.1117/12.863587). At that time, the twin-hole converted a incoming plane light wave into a pair of channel plasmon polaritons (CPPs), and united them at rear surface of the Ag film. This research is having an eye to extract, guide, and focus the SPPs through a thicker metal layer of the MIM with FIBed subwavelength pass-through holes. The expected outcome is a creation of noble, monochromatic, and tunable fiber probe for scanning near-field optical microscopes (SNOMs) with intense white light sources. Basic experimental and FEM simulation results will be presented.
NASA Astrophysics Data System (ADS)
Zwick, Harry; Zuclich, Joseph A.; Stuck, Bruce E.; Gagliano, Donald A.; Lund, David J.; Glickman, Randolph D.
1995-01-01
We have evaluated acute laser retinal exposure in non-human primates using a Rodenstock scanning laser ophthalmoscope (SLO) equipped with spectral imaging laser sources at 488, 514, 633, and 780 nm. Confocal spectral imaging at each laser wavelength allowed evaluation of the image plane from deep within the retinal vascular layer to the more superficial nerve fiber layer in the presence and absence of the short wavelength absorption of the macular pigment. SLO angiography included both fluorescein and indocyanine green procedures to assess the extent of damage to the sensory retina, the retinal pigment epithelium (RPE), and the choroidal vasculature. All laser exposures in this experiment were from a Q-switched Neodymium laser source at an exposure level sufficient to produce vitreous hemorrhage. Confocal imaging of the nerve fiber layer revealed discrete optic nerve sector defects between the lesion site and the macula (retrograde degeneration) as well as between the lesion site and the optic disk (Wallerian degeneration). In multiple hemorrhagic exposures, lesions placed progressively distant from the macula or overlapping the macula formed bridging scars visible at deep retinal levels. Angiography revealed blood flow disturbance at the retina as well as at the choroidal vascular level. These data suggest that acute parafoveal laser retinal injury can involve both direct full thickness damage to the sensory and non-sensory retina and remote nerve fiber degeneration. Such injury has serious functional implications for both central and peripheral visual function.
Ultrasonic Assessment of Impact-Induced Damage and Microcracking in Polymer Matrix Composites
NASA Technical Reports Server (NTRS)
Gyekanyesi, John (Technical Monitor); Liaw, Benjamin; Villars, Esther; Delmont, Frantz
2003-01-01
The main objective of this NASA Faculty Awards for Research (FAR) project is to conduct ultrasonic assessment of impact-induced damage and microcracking in fiber-metal laminated (FML) composites at various temperatures. It is believed that the proposed study of impact damage assessment on FML composites will benefit several NASA's missions and current interests, such as ballistic impact testing of composite fan containment and high strain rate deformation modeling of polymer matrix composites. Impact-induced damage mechanisms in GLARE and ARALL fiber-metal laminates subject to instrumented drop-weight impacts at various temperatures were studied. GLARE and ARALL are hybrid composites made of alternating layers of aluminum and glass- (for GLARE) and aramid- (for ARALL) fiber reinforced epoxy. Damage in pure aluminum panels impacted by foreign objects was mainly characterized by large plastic deformation surrounding a deep penetration dent. On the other hand, plastic deformation in fiber-metal laminates was often not as severe although the penetration dent was still produced. The more stiff fiber-reinforced epoxy layers provided better bending rigidity; thus, enhancing impact damage tolerance. Severe cracking, however, occurred due to the use of these more brittle fiber-reinforced epoxy layers. Fracture patterns, e.g., crack length and delamination size, were greatly affected by the lay-up configuration rather than by the number of layers, which implies that thickness effect was not significant for the panels tested in this study. Immersion ultrasound techniques were then used to assess damages generated by instrumented drop-weight impacts onto these fiber-metal laminate panels as well as 2024-T3 aluminum/cast acrylic sandwich plates adhered by epoxy. Depending on several parameters, such as impact velocity, mass, temperature, laminate configuration, sandwich construction, etc., various types of impact damage were observed, including plastic deformation, radiating cracks emanating from the impact site, ring cracks surrounding the impact site, partial and full delamination, and combinations of these damages.
NASA Astrophysics Data System (ADS)
Hirsch, Marzena; Wierzba, Paweł; Jedrzejewska-Szczerska, Małgorzata
2016-11-01
We examine the application of selected thin dielectric films, deposited by atomic layer deposition (ALD), in a low coherence fiber-optic Fabry-Pérot interferometer designed for sensing applications. Such films can be deposited on the end-face of a single mode optical fiber (SMF-28) in order to modify the reflectivity of the Fabry-Pérot cavity, to provide protection of the fibers from aggressive environments or to create a multi-cavity interferometric sensor. Spectral reflectance of films made from zinc oxide (ZnO), titanium dioxide (TiO2), aluminum oxide (Al2O3) and boron nitride (BN) was calculated for various thickness of the films and compared. The results show that the most promising materials for use in fiber-optic Fabry-Pérot interferometer are TiO2 and ZnO, although Al2O3 is also suitable for this application.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sabau, Adrian S.; Greer, Clayton M.; Chen, Jian
Here, the increasing use of Carbon Fiber-reinforced Polymer matrix Composites (CFPC) and aluminum alloys as lightweight materials in the automotive and aerospace industries demands enhanced surface preparation and control of surface morphology prior to joining. In this study, surfaces of both composite and aluminum were prepared for joining using an Nd:YAG laser in a two-beam interference setup, enabling the (a) structuring of the AL 5182 surface, (b) removal of the resin layer on top of carbon fibers, and (c) structuring of the carbon fibers. CFPC specimens of T700S carbon fiber, Prepreg - T8 3 epoxy, 5 ply thick, 0/90o plaquesmore » were used. The effect of laser fluence, scanning speed, and number of shots-per-spot was investigated on the removal rate of the resin without an excessive damage of the fibers. Optical micrographs, 3D imaging, and scanning electron microscope (SEM) imaging were used to study the effect of the laser processing on surface morphology.« less
Surface Modification of Carbon Fiber Polymer Composites after Laser Structuring
NASA Astrophysics Data System (ADS)
Sabau, Adrian S.; Chen, Jian; Jones, Jonaaron F.; Hackett, Alexandra; Jellison, Gerald D.; Daniel, Claus; Warren, David; Rehkopf, Jackie D.
The increasing use of Carbon Fiber-reinforced Polymer matrix Composites (CFPC) as a lightweight material in automotive and aerospace industries requires the control of surface morphology. In this study, the composites surface was prepared by ablating the resin on the top fiber layer of the composite using an Nd:YAG laser. The CFPC specimens with T700S carbon fiber and Prepreg — T83 resin (epoxy) were supplied by Plasan Carbon Composites, Inc. as 4 ply thick, 0/90° plaques. The effect of laser fluence, scanning speed, and wavelength was investigated on the removal rate of the resin without an excessive damage of the fibers. In addition, resin ablation due to the power variation created by a laser interference technique is presented. Optical property measurements, optical micrographs, 3D imaging, and high-resolution optical profiler images were used to study the effect of the laser processing on surface morphology.
Nanosized CaP-silk fibroin-PCL-PEG-PCL/PCL based bilayer membranes for guided bone regeneration.
Türkkan, Sibel; Pazarçeviren, A Engin; Keskin, Dilek; Machin, Nesrin E; Duygulu, Özgür; Tezcaner, Ayşen
2017-11-01
Guided bone regeneration (GBR) concept has been developed to prevent the formation of non-functional scar tissue layer on defect site by undertaking barrier role. In this study, a new bilayer membrane which consisted of one layer of electrospun silk fibroin/PCL-PEG-PCL incorporating nanocalcium phosphate (SPCA) 1 and one layer of PCL membrane was developed for GBR. To improve the osteoconductivity of membranes, nanosized calcium phosphate particles synthesized by Flame Spray Pyrolysis method were incorporated into membranes at 10% (wt) (SPCA10) and 20% (wt) (SPCA20) of the polymer content. The structural and chemical analyses revealed the well-integrated two layers of membranes with a total thickness of ca 100μm. In the regenerative layer, the highly porous mesh structure had a thickness of 12.6μm with randomly oriented fibers having diameters around 760nm, and nanoparticles dispersed homogenously. The mechanical test results showed remarkable improvement on the tensile strength of membranes with incorporation of nanoparticles. Higher water affinity of nanoCaP included membranes was proved by lower contact angle values and higher percent water uptake capacity. Biomineralization assay revealed that nucleation and growth of apatites around fibers of SPCA10 and SPCA20 were apparent while on SPCA0 apatite minerals were barely detected after 10days. Human dental pulp stem cells (DPSC) were seeded on electrospun layer of the bilayer membranes for biocompatibility and osteo-compatibility study. Increasing nanoCaP amount resulted in higher cell adhesion, proliferation, ALP activity and calcium deposition on membranes. These overall results confirmed the biocompatibility and potential applicability of proposed membranes for GBR treatments. Copyright © 2017 Elsevier B.V. All rights reserved.
The association of Helicobacter pylori with choroidal and retinal nerve fiber layer thickness.
Can, Mehmet Erol; Kaplan, Fatma Efe; Uzel, Mehmet Murat; Kiziltoprak, Hasan; Ergun, Mustafa Cagri; Koc, Mustafa; Simsek, Gülcin
2017-08-05
To investigate the effect of Helicobacter pylori (H. pylori) infection on choroidal thickness (CT) and retinal nerve fiber layer thickness (RNFLT). The study included 25 patients with H. pylori infection and 25 healthy individuals as the control group. Helicobacter pylori patients were classified as the pre-treatment (Group 1; n: 25) and the post-treatment (Group 2; n: 25). RNFLT and CT were measured before and after treatment of H. pylori infection, using enhanced depth imaging (EDI) spectral-domain optical coherence tomography (Spectralis, Heidelberg Engineering, Heidelberg, Germany). The axial length and intraocular pressure were also measured. The mean subfoveal CT was 320.96 ± 29.15 μm in Group 1 and 287.48 ± 49.17 in the control group (p = 0.007), while the mean subfoveal CT did not show any difference between Group 2 and the control group (p > 0.05). No statistically significant difference was determined between the H. pylori patients and the control group in respect of RNFLT values (p > 0.05). CT increases during H. pylori infection and returns to the normal range within 6 weeks of treatment. RNFLT does not show any change during H. pylori infection. The data related to the subfoveal CT may be useful in understanding the pathogenesis of central serous chorioretinopathy developing in H. pylori patients.
Liu, G Y; Utset, T O; Bernard, J T
2015-10-01
Due to the lack of reliable biomarkers in diagnosing and monitoring neuropsychiatric systemic lupus erythematosus (NPSLE), the aim of this study was to examine the utility of measurements obtained through spectral domain optical coherence tomography (SD-OCT) as a biomarker for NP involvement in SLE. Retinal nerve fiber layer (RNFL) and macula scans were performed using SD-OCT on 15 NPSLE patients, 16 SLE patients without NP symptoms (non-NP SLE), and 16 healthy controls. Macular volume and thickness of the central macula and peripapillary RNFL were compared between the groups and to scores on two validated cognitive tests. NPSLE patients did not differ significantly from non-NP SLE patients in retinal thickness or macular volume. However, SLE patients as a whole showed significant RNFL and macular thinning compared to controls. Scores on the Trail Making Test B, a test of complex attention, showed significant correlation to temporal superior and temporal inferior RNFL thickness. Our results demonstrate RNFL thinning in SLE, and confirm the previous finding of high incidence of abnormal brain scans in SLE. These findings suggest that OCT measurements may be indicative of neurodegeneration in SLE and may be a useful biomarker for early cognitive impairment in SLE. © The Author(s) 2015 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Influence of metal bonding layer on strain transfer performance of FBG
NASA Astrophysics Data System (ADS)
Liu, Hao; Chen, Weimin; Zhang, Peng; Liu, Li; Shu, Yuejie; Wu, Jun
2013-01-01
Metal bonding layer seriously affects the strain transfer performance of Fiber Bragg Grating (FBG). Based on the mode of FBG strain transfer, the influence of the length, the thickness, Poisson's ratio, elasticity modulus of metal bonding layer on the strain transfer coefficient of FBG is analyzed by numerical simulation. FBG is packaged to steel wire using metal bonding technology of FBG. The tensile tests of different bonding lengths and elasticity modulus are carried out. The result shows the strain transfer coefficient of FBGs are 0.9848,0.962 and their average strain sensitivities are 1.076 pm/μɛ,1.099 pm/μɛ when the metal bonding layer is zinc, whose lengths are 15mm, 20mm, respectively. The strain transfer coefficient of FBG packaged by metal bonding layer raises 8.9 percent compared to epoxy glue package. The preliminary experimental results show that the strain transfer coefficient increases with the length of metal bonding layer, decreases with the thickness of metal bonding layer and the influence of Poisson's ratio can be ignored. The experiment result is general agreement with the analysis and provides guidance for metal package of FBG.
Dehghani, Cirous; Srinivasan, Sangeetha; Edwards, Katie; Pritchard, Nicola; Russell, Anthony W; Malik, Rayaz A; Efron, Nathan
2017-05-01
Reduced retinal nerve fiber layer (RNFL) thickness has been demonstrated in patients with diabetic peripheral neuropathy (DPN) in cross-sectional studies. This prospective study defines longitudinal alterations to the RNFL thickness in individuals with type 1 diabetes without (DPN-ve) and with (DPN+ve) DPN and in relation to risk factors for nerve damage. A cohort of 105 individuals with type 1 diabetes (20% DPN+ve) with predominantly mild or no retinopathy and no previous retinal photocoagulation underwent spectral-domain optical coherence tomography (SD-OCT) at baseline, 2 years, and 4 years. SD-OCT scans were acquired at 3.45-mm diameter around the optic nerve head and the overall RNFL and RNFL in the nasal, superior, temporal, and inferior quadrants were quantified. By including serial quantified RNFL parameters, linear mixed models were applied to assess the change in RNFL thickness over time and to explore the associations with other clinical variables. There was a significant decline in the overall RNFL thickness (-0.7 μm/y, P = 0.02) and RNFL in the superior quadrant (-1.9 μm/y, P < 0.01) in the DPN+ve group compared with DPN-ve group. The overall RNFL thickness and RNFL in the superior and nasal quadrants were inversely associated with age (β = -0.29, -0.41, and -0.29, respectively; P ≤ 0.02). Sex, retinopathy, diabetes duration, hemoglobin A1c, lipid profile, blood pressure, cigarette use, alcohol consumption, and body mass index did not show any significant effects (P > 0.05). Individuals with DPN showed a progressive RNFL thinning overall and in the superior quadrant, which was more pronounced in older individuals. There may be common pathways for retinal and peripheral neurodegeneration that are independent of conventional DPN risk factors.
Xu, WanWan; Kurup, Sudhi P; Fawzi, Amani A; Durbin, Mary K; Maumenee, Irene H; Mets, Marilyn B
2017-01-01
To report the distribution of macular and optic nerve topography in the eyes of individuals with Marfan syndrome aged 8-56 years using spectral domain optical coherence tomography (SD-OCT). Thirty-three patients with Marfan syndrome underwent a full eye examination including slit-lamp biomicroscopy, indirect ophthalmoscopy, and axial length measurement; and SD-OCT measurements of the retinal nerve fiber layer (RNFL) and macular thickness. For patients between the ages of 8 and 12 years, the average RNFL thickness is 98 ± 9 μm, the vertical cup to disc (C:D) ratio is 0.50 ± 0.10, the central subfield thickness (CST) is 274 ± 38 μm, and the macular volume is 10.3 ± 0.6 mm 3 . For patients between the ages of 13 and 17 years, the average RNFL is 86 ± 16 μm, the vertical C:D ratio is 0.35 ± 0.20, the CST is 259 ± 15 μm, and the macular volume is 10.1 ± 0.5 mm 3 . For patients 18 years or older, the average RNFL is 89 ± 12 μm, the vertical C:D ratio is 0.46 ± 0.18, the CST is 262 ± 20 μm, and the macular volume is 10.2 ± 0.4 mm 3 . When the average RNFL data are compared to a normative, age-adjusted database, 6 of 33 (18%) were thinner than the 5% limit. This study reports the distribution of SD-OCT data for patients with Marfan syndrome. Compared to a normative database, 18% of eyes with Marfan syndrome had RNFL thickness < 5% of the population.
Ozge, Gokhan; Koylu, Mehmet Talay; Mumcuoglu, Tarkan; Gundogan, Fatih Cakir; Ozgonul, Cem; Ayyildiz, Onder; Kucukevcilioglu, Murat
2016-05-01
To compare retinal nerve fiber layer thickness (RNFLT) and choroidal thickness (ChT) measurements in eyes with pseudoexfoliative (PEX) glaucoma, PEX syndrome and healthy control eyes. Eighteen patients with PEX glaucoma in one eye and PEX syndrome in the fellow eye were included. The right eyes of thirty-nine age- and sex-matched healthy subjects were included as control group. All participants underwent a detailed biomicroscopic and funduscopic examination. RNFLT and ChT measurements were performed with a commercially available spectral-domain optical coherence tomography (SD-OCT). ChT measurements were performed by using enhanced depth imaging (EDI) mode. Patients with PEX underwent diurnal IOP measurements with 4-hour intervals before inclusion in the study. RNFLT results included the average measurement and 6 quadrants (temporal, inferotemporal, inferonasal, nasal, superonasal and supero-temporal). ChT measurements were performed in the subfoveal region and around the fovea (500µm and 1500 µm nasal and temporal to the fovea), as well as around the optic disc (average peripapillary and eight quadrants in the peripapillary region (temporal, inferotemporal, inferior, inferonasal, nasal, superonasal, superior, supero-temporal)). RNFLT in all quadrants and average thickness were significantly lower in PEX glaucoma eyes compared to PEX syndrome eyes and healthy control eyes (p<0.001 for both). RNFLT comparisons between PEX syndrome and healthy control eyes did not show a significant difference (p>0.05) except the inferotemporal quadrant. ChT measurements were similar between groups (p>0.05). Thinning of the RNFL in association with unchanged ChT may mean that the presence of PEX material is a much more significant risk factor than choroidal changes in the progression of PEX syndrome to PEX glaucoma.
NASA Technical Reports Server (NTRS)
Bansal, Narottam P.
2008-01-01
BN/SiC-coated Hi-Nicalon fiber-reinforced celsian matrix composites (CMC) were annealed for 100 h in air at various temperatures to 1200 C, followed by flexural strength measurements at room temperature. Values of yield stress and strain, ultimate strength, and composite modulus remain almost unchanged for samples annealed up to 1100 C. A thin porous layer formed on the surface of the 1100 C annealed sample and its density decreased from 3.09 to 2.90 g/cu cm. The specimen annealed at 1200 C gained 0.43 wt%, was severely deformed, and was covered with a porous layer of thick shiny glaze which could be easily peeled off. Some gas bubbles were also present on the surface. This surface layer consisted of elongated crystals of monoclinic celsian and some amorphous phase(s). The fibers in this surface ply of the CMC had broken into small pieces. The fiber-matrix interface strength was characterized through fiber push-in technique. Values of debond stress, alpha(sub d), and frictional sliding stress, tau(sub f), for the as-fabricated CMC were 0.31+/-0.14 GPa and 10.4+/-3.1 MPa, respectively. These values compared with 0.53+/-0.47 GPa and 8.33+/-1.72 MPa for the fibers in the interior of the 1200 C annealed sample, indicating hardly any change in fiber-matrix interface strength. The effects of thermal aging on microstructure were investigated using scanning electron microscopy. Only the surface ply of the 1200 C annealed specimens had degraded from oxidation whereas the bulk interior part of the CMC was unaffected. A mechanism is proposed explaining the various steps involved during the degradation of the CMC on annealing in air at 1200 C.
Isothermal and hygrothermal agings of hybrid glass fiber/carbon fiber composite
NASA Astrophysics Data System (ADS)
Barjasteh, Ehsan
New applications of fiber-reinforced polymer composites (FRPCs) are arising in non-traditional sectors of industry, such as civil infrastructure, automotive, and power distribution. For example, composites are being used in place of steel to support high-voltage overhead conductors. In this application, conductive strands of aluminum are wrapped around a solid composite rod comprised of unidirectional carbon and glass fibers in an epoxy matrix, which is commercially called ACCC conductor. Composite-core conductors such as these are expected to eventually replace conventional steel-reinforced conductors because of the reduced sag at high temperatures, lower weight, higher ampacity, and reduced line losses. Despite the considerable advantages in mechanical performance, long-term durability of composite conductors is a major concern, as overhead conductors are expected to retain properties (with minimal maintenance) over a service life that spans multiple decades. These concerns stem from the uncertain effects of long-term environmental exposure, which includes temperature, moisture, radiation, and aggressive chemicals, all of which can be exacerbated by cyclic loads. In general, the mechanical and physical properties of polymer composites are adversely affected by such environmental factors. Consequently, the ability to forecast changes in material properties as a function of environmental exposure, particularly bulk mechanical properties, which are affected by the integrity of fiber-matrix interfaces, is required to design for extended service lives. Polymer composites are susceptible to oxidative degradation at high temperatures approaching but not quite reaching the glass transition temperature ( Tg). Although the fibers are stable at such temperatures, the matrix and especially the fiber-matrix interface can undergo degradation that affects the physical and mechanical properties of the structure over time. Therefore, as a first step, the thermal aging of an anhydride/epoxy network used in composite-reinforced conductor cables was investigated to determine the extent of thermal oxidative (surface effect) and non-oxidative (bulk effect) degradation. Thermal oxidation tests were performed in air-circulating and vacuum ovens at 180°C and 200ºC (the maximum emergency temperature for ACCC conductors). The extent of oxidation during aging was determined by monitoring the thickness of the oxidized layer. Results showed that the oxidized layer thickness did not increase monotonically as a function of exposure time, and even decreased for a limited period of time. A phenomenological reaction-diffusion model was implemented to predict the thickness of oxidized layer, and the calculated results were compared with measurements for aging times up to 10,000 hours. The accuracy of the reaction-diffusion-based thickness values for the isothermally aged epoxy specimen was affected by the permeability properties of the oxidized material, and to a lesser extent by the degree of oxidation. The diffusivity varied because of changes in the density of the oxidized layer, the macro-void content, crack formation, and the molecular structures. To investigate the effects on diffusivity, the morphology of the oxidized layer and the void content was monitored over time. In addition, the density of the oxidized specimens was calculated by direct measurements of volume and weight during exposure. An empirically based volume-loss model was developed to predict the changes in volume of the specimen as a function of aging times and hence to predict the effects on the oxidized layer thickness. Volume-loss measurements provide an indication of material degradation by demonstrating a direct measurement of shrinkage rates and insight into crack initiation, as opposed to typical weight-loss measurements that provide no insight into material failure. Thermal oxidation of a unidirectional carbon-fiber/glass-fiber hybrid composite was also investigated in this study. The aim was to determine oxidation kinetics, degradation mechanisms, oxidation thickness growth (a damage indicator), and oxidation effects on mechanical property. The epoxy composite rods were comprised of a carbon-fiber core and a glass-fiber shell. The thickness of the oxidized layer (TOL) was measured experimentally for samples exposed to 180ºC and 200ºC for up to 8,736 hours. A reaction-diffusion model was developed for each of the two hybrid sections to obtain the oxygen-concentration profile and the TOL within the composite rods. The TOL values measured experimentally were similar to the modeling predictions. The glass-fiber shell functioned as a protective layer, limiting the oxidation of the carbon-fiber core. The domain validity for the reaction-diffusion model was determined from gravimetric experiments by measuring the weight-loss of hybrid composite samples exposed isothermally in air and in vacuum at 200°C for up to 13,104 hours (1.5 years). The results showed that after prolonged thermal exposure, the degradation mechanism changed from thermal oxidation to thermal degradation. Thermogravimetric analysis (TGA) was performed to determine the thermal degradation and stability of the aged composite. The results indicated that the onset temperature of matrix degradation increased by increasing exposure time. Inorganic fillers are widely used in pultruded parts to facilitate pultrusion, especially for long production runs. Therefore, another scope of this study was to investigate the effects of filler on oxidation kinetics and degradation mechanisms during thermal aging of prultruded composite rods. Similar aging tests and oxidation modeling to those for the unfilled composites were performed. The predicted and measured TOL values for filled composites were slightly less than those for unfilled composites. The addition of kaolin fillers did not affect the oxidation mechanism or the reaction rate of the epoxy matrix, although it did cause a slight decrease in the oxygen-transport properties (diffusivity and solubility of oxygen). The effect of thermal aging on mechanical properties of the aged composites was investigated. A relationship was derived relating TOL to tensile strength of the hybrid composite. The tensile strength remained essentially unchanged by thermal oxidation after 52 weeks of exposure. On the contrary, the oxidation resulted in a decrease in short-beam-shear (SBS) strength (a matrix-dominated property) due to degradation of matrix and fiber/matrix interface strength. However, the filled composites showed a lower reduction in SBS strength than that of the unfilled one for an identical duration of exposure. In addition, the effect of thermal aging on glass transition temperature (T g) was determined for isothermal exposures at 180ºC and 200ºC. The simultaneous effects of post-curing and thermal degradation resulted in the change in Tg during exposure. Another study on the composite rod was performed to investigate the sorption kinetics and the effects of moisture on mechanical and physical properties. Sorption curves were obtained for both hybrid and non-hybrid composite rods to determine characteristic parameters, including the diffusion coefficient (D) and the maximum moisture uptake (Minfinity ). The moisture uptake for the hybrid composites generally exhibited Fickian behavior (no hybridization effects), behaving much like non-hybrid composites. A two-dimensional diffusion model was employed to calculate moisture diffusivities in the longitudinal direction. Interfaces and thermally-induced residual stresses affected the moisture diffusion. In addition, the effect of hygrothermal aging on glass transition temperature (Tg), short beam shear strength (SBS), and tensile strength was determined for hygrothermal exposure at 60°C and 85% relative humidity (RH). Property retention and reversibility of property degradation was also measured. Microscopic inspection revealed no evidence of damage. Prediction of the lifetime of carbon-fiber/fiberglass (GF/CF) hybrid composites under various loads and service life conditions requires fundamental knowledge about the degradation mechanisms associated with overhead conductors with the hybrid GF/CF composite cores. This study provides adequate information on mechanical and thermal behaviors of the composite core under prolong isothermal and hygrothermal exposure, which is necessary for defining a lifetime model.
Retinal Nerve Fiber Layer Segmentation on FD-OCT Scans of Normal Subjects and Glaucoma Patients.
Mayer, Markus A; Hornegger, Joachim; Mardin, Christian Y; Tornow, Ralf P
2010-11-08
Automated measurements of the retinal nerve fiber layer thickness on circular OCT B-Scans provide physicians additional parameters for glaucoma diagnosis. We propose a novel retinal nerve fiber layer segmentation algorithm for frequency domain data that can be applied on scans from both normal healthy subjects, as well as glaucoma patients, using the same set of parameters. In addition, the algorithm remains almost unaffected by image quality. The main part of the segmentation process is based on the minimization of an energy function consisting of gradient and local smoothing terms. A quantitative evaluation comparing the automated segmentation results to manually corrected segmentations from three reviewers is performed. A total of 72 scans from glaucoma patients and 132 scans from normal subjects, all from different persons, composed the database for the evaluation of the segmentation algorithm. A mean absolute error per A-Scan of 2.9 µm was achieved on glaucomatous eyes, and 3.6 µm on healthy eyes. The mean absolute segmentation error over all A-Scans lies below 10 µm on 95.1% of the images. Thus our approach provides a reliable tool for extracting diagnostic relevant parameters from OCT B-Scans for glaucoma diagnosis.
Retinal Nerve Fiber Layer Segmentation on FD-OCT Scans of Normal Subjects and Glaucoma Patients
Mayer, Markus A.; Hornegger, Joachim; Mardin, Christian Y.; Tornow, Ralf P.
2010-01-01
Automated measurements of the retinal nerve fiber layer thickness on circular OCT B-Scans provide physicians additional parameters for glaucoma diagnosis. We propose a novel retinal nerve fiber layer segmentation algorithm for frequency domain data that can be applied on scans from both normal healthy subjects, as well as glaucoma patients, using the same set of parameters. In addition, the algorithm remains almost unaffected by image quality. The main part of the segmentation process is based on the minimization of an energy function consisting of gradient and local smoothing terms. A quantitative evaluation comparing the automated segmentation results to manually corrected segmentations from three reviewers is performed. A total of 72 scans from glaucoma patients and 132 scans from normal subjects, all from different persons, composed the database for the evaluation of the segmentation algorithm. A mean absolute error per A-Scan of 2.9 µm was achieved on glaucomatous eyes, and 3.6 µm on healthy eyes. The mean absolute segmentation error over all A-Scans lies below 10 µm on 95.1% of the images. Thus our approach provides a reliable tool for extracting diagnostic relevant parameters from OCT B-Scans for glaucoma diagnosis. PMID:21258556
Effects of heat/citric acid reprocessing on high-flux polysulfone dialyzers.
Cornelius, Rena M; McClung, W Glenn; Richardson, Robert M A; Estridge, Charles; Plaskos, Nicholas; Yip, Christopher M; Brash, John L
2002-01-01
The surface features, morphology, and tensile properties of fibers obtained from pristine, reprocessed, and reused Fresenius Polysulfone High-Flux (Hemoflow F80A) hemodialyzers have been studied. Scanning electron microscopy of the dialyzer fibers revealed a dense skin layer on the inner surface of the membrane and a relatively thick porous layer on the outer surface. Transmission electron microscopy and atomic force microscopy showed an alteration in membrane morphology due to reprocessing and reuse, or to a deposition of blood-borne material on the membrane that is not removed with reprocessing. Fluorescent microscopy images also showed that a fluorescent material not removed by heat/citric acid reprocessing builds up with continued use of the dialyzers. The tensile properties of the dialyzer fibers were not affected by the heat/citric acid reprocessing procedure. The protein layers formed on pristine and reused hemodialyzer membranes during clinical use were also studied using sodium dodecyl sulfate polyacrylamide gel electrophoresis and immunoblotting. A considerable amount of protein was found on the blood side of single and multiple use dialyzers. Proteins adsorbed on the dialysate side of the membrane were predominantly in the molecular weight region below 30 kDa. Little protein was detected on the membranes of reprocessed hemodialyzers.
Delamination Defect Detection Using Ultrasonic Guided Waves in Advanced Hybrid Structural Elements
NASA Astrophysics Data System (ADS)
Yan, Fei; Qi, Kevin ``Xue''; Rose, Joseph L.; Weiland, Hasso
2010-02-01
Nondestructive testing for multilayered structures is challenging because of increased numbers of layers and plate thicknesses. In this paper, ultrasonic guided waves are applied to detect delamination defects inside a 23-layer Alcoa Advanced Hybrid Structural plate. A semi-analytical finite element (SAFE) method generates dispersion curves and wave structures in order to select appropriate wave structures to detect certain defects. One guided wave mode and frequency is chosen to achieve large in-plane displacements at regions of interest. The interactions of the selected mode with defects are simulated using finite element models. Experiments are conducted and compared with bulk wave measurements. It is shown that guided waves can detect deeply embedded damages inside thick multilayer fiber-metal laminates with suitable mode and frequency selection.
Retinal nerve fiber layer thickness map and blood flow pulsation measured with SDOCT
NASA Astrophysics Data System (ADS)
Mujat, Mircea; Chan, Raymond C.; Cense, Barry; Pierce, Mark; Park, Hyle; Joo, Chulmin; Chen, Teresa C.; de Boer, Johannes F.
2006-02-01
Spectral-Domain Optical Coherence Tomography (SDOCT) allows for in-vivo video-rate investigation of biomedical tissue depth structure intended for non-invasive optical diagnostics. It has been suggested that OCT can be used for di-agnosis of glaucoma by measuring the thickness of the Retinal Nerve Fiber Layer (RNLF). We present an automated method for determining the RNFL thickness from a 3-D dataset based on edge detection using a deformable spline algo-rithm. The RNFL thickness map is combined with an integrated reflectance map and retinal cross-sectional images to provide the ophthalmologist with a familiar image for interpreting the OCT data. The video-rate capabilities of our SDOCT system allow for mapping the true retinal topography since motion artifacts are significantly reduced as com-pared to slower time-domain systems. Combined with Doppler Velocimetry, SDOCT also provides information on retinal blood flow dynamics. We analyzed the pulsatile nature of the bidirectional flow dynamics in an artery-vein pair for a healthy volunteer at different locations and for different blood vessel diameters. The Doppler phase shift is determined as the phase difference at the same point of adjacent depth profiles, and is integrated over the area delimited by two circles corresponding to the blood vessels location. Its temporal evolution clearly shows the blood flow pulsatile nature, the cardiac cycle, in both artery and vein. The artery is identified as having a stronger variation of the integrated phase shift. We observe that artery pulsation is always easily detectable, while vein pulsation seems to depend on the veins diameter.
Yamashita, Takehiro; Asaoka, Ryo; Kii, Yuya; Terasaki, Hiroto; Murata, Hiroshi; Sakamoto, Taiji
2017-01-01
The location of the peaks of the circumpapillary retinal nerve fiber layer (cpRNFL) thickness is affected by several ocular parameters. In this study, we have generated equations that can determine the peaks of the cpRNFL. This study was a prospective, observational, cross sectional study of 118 healthy right eyes. The axial length, optic disc tilt, superiortemporal (ST)- and inferiortemporal (IT)-peaks of the cpRNFL thickness, and angles of the ST and IT retinal arteries (RA) and veins (RV) were determined. The correlations between the location of the ST- and IT-peaks and ocular structural parameters and the sex, body height and weight were calculated. The best fit equations to generate the location of the ST/IT-peaks were determined using corrected-Akaike Information Criteria. The location of the ST-peak was 0.72+(0.40 x ST-RA)+(0.27 x ST-RV)+(0.14 x height)-(0.47 x papillo-macular-position)-(0.11 x disc tilt) with a coefficient of correlation of 0.61 (P<0.0001). The location of the IT-peak was 21.88+(0.53 x IT-RA)+(0.15 x IT-RV)+(0.041 x corneal thickness)-(1.00 x axial length) with a coefficient of correlation of 0.59 (P<0.0001). The location of ST/IT peaks is determined by different parameters of the ocular structure. These equations allow clinicians to obtain an accurate location of the peaks for a more accurate diagnosis of glaucoma.
Zeng, Jingbin; Liu, Haihong; Chen, Jinmei; Huang, Jianli; Yu, Jianfeng; Wang, Yiru; Chen, Xi
2012-09-21
In this paper, we have, for the first time, proposed an approach by combining self-assembled monolayers (SAMs) and nanomaterials (NMs) for the preparation of novel solid-phase microextraction (SPME) coatings. The self-assembly of octadecyltrimethoxysilane (OTMS) on the surface of ZnO nanorods (ZNRs) was selected as a model system to demonstrate the feasibility of this approach. The functionalization of OTMS on the surface of ZNRs was characterized and confirmed using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). The OTMS-ZNRs coated fiber exhibited stronger hydrophobicity after functionalization, and its extraction efficiency for non-polar benzene homologues was increased by a factor of 1.5-3.6 when compared to a ZNRs fiber with almost identical thickness and façade. In contrast, the extraction efficiency of the OTMS-ZNRs coated fiber for polar aldehydes was 1.6-4.0-fold lower than that of the ZNRs coated fiber, further indicating its enhanced surface hydrophobicity. The OTMS-ZNRs coated fiber revealed a much higher capacity upon increasing the OTMS layer thickness to 5 μm, leading to a factor of 12.0-13.4 and 1.8-2.5 increase in extraction efficiency for the benzene homologues relative to a ZNRs coated fiber and a commercial PDMS fiber, respectively. The developed HS-SPME-GC method using the OTMS-ZNRs coated fiber was successfully applied to the determination of the benzene homologues in limnetic water samples with recovery ranging from 83 to 113% and relative standard deviations (RSDs) of less than 8%.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sabau, Adrian S; Chen, Jian; Jones, Jonaaron F.
The increasing use of Carbon Fiber Polymer Composite (CFPC) as a lightweight material in automotive and aerospace industries requires the control of surface morphology. In this study, the composites surface was prepared by ablating the resin in the top fiber layer of the composite using an Nd:YAG laser. The CFPC specimens with T700S carbon fiber and Prepreg - T83 resin (epoxy) were supplied by Plasan Carbon Composites, Inc. as 4 ply thick, 0/90o plaques. The effect of laser fluence, scanning speed, and wavelength was investigated to remove resin without an excessive damage of the fibers. In addition, resin ablation duemore » to the power variation created by a laser interference technique is presented. Optical property measurements, optical micrographs, 3D imaging, and high-resolution optical profiler images were used to study the effect of the laser processing on the surface morphology.« less
Development of GENOA Progressive Failure Parallel Processing Software Systems
NASA Technical Reports Server (NTRS)
Abdi, Frank; Minnetyan, Levon
1999-01-01
A capability consisting of software development and experimental techniques has been developed and is described. The capability is integrated into GENOA-PFA to model polymer matrix composite (PMC) structures. The capability considers the physics and mechanics of composite materials and structure by integration of a hierarchical multilevel macro-scale (lamina, laminate, and structure) and micro scale (fiber, matrix, and interface) simulation analyses. The modeling involves (1) ply layering methodology utilizing FEM elements with through-the-thickness representation, (2) simulation of effects of material defects and conditions (e.g., voids, fiber waviness, and residual stress) on global static and cyclic fatigue strengths, (3) including material nonlinearities (by updating properties periodically) and geometrical nonlinearities (by Lagrangian updating), (4) simulating crack initiation. and growth to failure under static, cyclic, creep, and impact loads. (5) progressive fracture analysis to determine durability and damage tolerance. (6) identifying the percent contribution of various possible composite failure modes involved in critical damage events. and (7) determining sensitivities of failure modes to design parameters (e.g., fiber volume fraction, ply thickness, fiber orientation. and adhesive-bond thickness). GENOA-PFA progressive failure analysis is now ready for use to investigate the effects on structural responses to PMC material degradation from damage induced by static, cyclic (fatigue). creep, and impact loading in 2D/3D PMC structures subjected to hygrothermal environments. Its use will significantly facilitate targeting design parameter changes that will be most effective in reducing the probability of a given failure mode occurring.
Zhou, Zehang; Panatdasirisuk, Weerapha; Mathis, Tyler S; Anasori, Babak; Lu, Canhui; Zhang, Xinxing; Liao, Zhiwei; Gogotsi, Yury; Yang, Shu
2018-03-29
Free-standing, highly flexible and foldable supercapacitor electrodes were fabricated through the spray-coating assisted layer-by-layer assembly of Ti3C2Tx (MXene) nanoflakes together with multi-walled carbon nanotubes (MWCNTs) on electrospun polycaprolactone (PCL) fiber networks. The open structure of the PCL network and the use of MWCNTs as spacers not only limit the restacking of Ti3C2Tx flakes but also increase the accessible surface of the active materials, facilitating fast diffusion of electrolyte ions within the electrode. Composite electrodes have areal capacitance (30-50 mF cm-2) comparable to other templated electrodes reported in the literature, but showed significantly improved rate performance (14-16% capacitance retention at a scan rate of 100 V s-1). Furthermore, the composite electrodes are flexible and foldable, demonstrating good tolerance against repeated mechanical deformation, including twisting and folding. Therefore, these tens of micron thick fiber electrodes will be attractive for applications in energy storage, electroanalytical chemistry, brain electrodes, electrocatalysis and other fields, where flexible freestanding electrodes with an open and accessible surface are highly desired.
2004-11-01
surface prox- Experimental studies-l4 have shown that the ad- imity of the fiber changes the structure of the resin in sorption of an epoxy system... sorption layer to the ith bulk layer, and RdE(i + 1, The adsorbed state exchanges mass with the bulk i) is the rate term of the desorption of epoxy mole...thickness from -y = 0 to a ;5 nonzero value was primarily due to the shift in the 7 contribution to the interphase gradient from that of ad- 40 sorption
Menghini, Moreno; Lujan, Brandon J; Zayit-Soudry, Shiri; Syed, Reema; Porco, Travis C; Bayabo, Kristine; Carroll, Joseph; Roorda, Austin; Duncan, Jacque L
2014-12-16
We studied the correlation between outer nuclear layer (ONL) thickness and cone density in normal eyes and eyes with retinitis pigmentosa (RP). Spectral-domain optical coherence tomography (SD-OCT) scans were acquired using a displaced pupil entry position of the scanning beam to distinguish Henle's fiber layer from the ONL in 20 normal eyes (10 subjects) and 12 eyes with RP (7 patients). Cone photoreceptors were imaged using adaptive optics scanning laser ophthalmoscopy. The ONL thickness and cone density were measured at 0.5° intervals along the horizontal meridian through the fovea nasally and temporally. The ONL thickness and cone density were correlated using Spearman's rank correlation coefficient r. Cone densities averaged over the central 6° were lower in eyes with RP than normal, but showed high variability in both groups. The ONL thickness and cone density were significantly correlated when all retinal eccentricities were combined (r = 0.74); the correlation for regions within 0.5° to 1.5° eccentricity was stronger (r = 0.67) than between 1.5° and 3.0° eccentricity (r = 0.23). Although cone densities were lower between 0.5° and 1.5° in eyes with RP, ONL thickness measures at identical retinal locations were similar in the two groups (P = 0.31), and interindividual variation was high for ONL and cone density measures. Although ONL thickness and retinal eccentricity were important predictors of cone density, eccentricity was over 3 times more important. The ONL thickness and cone density were correlated in normal eyes and eyes with RP, but both were strongly correlated with retinal eccentricity, precluding estimation of cone density from ONL thickness. (ClinicalTrials.gov number, NCT00254605.). Copyright 2015 The Association for Research in Vision and Ophthalmology, Inc.
Menghini, Moreno; Lujan, Brandon J.; Zayit-Soudry, Shiri; Syed, Reema; Porco, Travis C.; Bayabo, Kristine; Carroll, Joseph; Roorda, Austin; Duncan, Jacque L.
2015-01-01
Purpose. We studied the correlation between outer nuclear layer (ONL) thickness and cone density in normal eyes and eyes with retinitis pigmentosa (RP). Methods. Spectral-domain optical coherence tomography (SD-OCT) scans were acquired using a displaced pupil entry position of the scanning beam to distinguish Henle's fiber layer from the ONL in 20 normal eyes (10 subjects) and 12 eyes with RP (7 patients). Cone photoreceptors were imaged using adaptive optics scanning laser ophthalmoscopy. The ONL thickness and cone density were measured at 0.5° intervals along the horizontal meridian through the fovea nasally and temporally. The ONL thickness and cone density were correlated using Spearman's rank correlation coefficient r. Results. Cone densities averaged over the central 6° were lower in eyes with RP than normal, but showed high variability in both groups. The ONL thickness and cone density were significantly correlated when all retinal eccentricities were combined (r = 0.74); the correlation for regions within 0.5° to 1.5° eccentricity was stronger (r = 0.67) than between 1.5° and 3.0° eccentricity (r = 0.23). Although cone densities were lower between 0.5° and 1.5° in eyes with RP, ONL thickness measures at identical retinal locations were similar in the two groups (P = 0.31), and interindividual variation was high for ONL and cone density measures. Although ONL thickness and retinal eccentricity were important predictors of cone density, eccentricity was over 3 times more important. Conclusions. The ONL thickness and cone density were correlated in normal eyes and eyes with RP, but both were strongly correlated with retinal eccentricity, precluding estimation of cone density from ONL thickness. (ClinicalTrials.gov number, NCT00254605.) PMID:25515570
Sabau, Adrian S.; Greer, Clayton M.; Chen, Jian; ...
2016-05-03
Here, the increasing use of Carbon Fiber-reinforced Polymer matrix Composites (CFPC) and aluminum alloys as lightweight materials in the automotive and aerospace industries demands enhanced surface preparation and control of surface morphology prior to joining. In this study, surfaces of both composite and aluminum were prepared for joining using an Nd:YAG laser in a two-beam interference setup, enabling the (a) structuring of the AL 5182 surface, (b) removal of the resin layer on top of carbon fibers, and (c) structuring of the carbon fibers. CFPC specimens of T700S carbon fiber, Prepreg - T8 3 epoxy, 5 ply thick, 0/90o plaquesmore » were used. The effect of laser fluence, scanning speed, and number of shots-per-spot was investigated on the removal rate of the resin without an excessive damage of the fibers. Optical micrographs, 3D imaging, and scanning electron microscope (SEM) imaging were used to study the effect of the laser processing on surface morphology.« less
Experimental investigation of sound absorption properties of perforated date palm fibers panel
NASA Astrophysics Data System (ADS)
Elwaleed, A. K.; Nikabdullah, N.; Nor, M. J. M.; Tahir, M. F. M.; Zulkifli, R.
2013-06-01
This paper presents the sound absorption properties of a natural waste of date palm fiber perforated panel. A single layer of the date palm fibers was tested in this study for its sound absorption properties. The experimental measurements were carried out using impedance tube at the acoustic lab, Faculty of Engineering, Universiti Kebangsaan Malaysia. The experiment was conducted for the panel without air gap, with air gap and with perforated plate facing. Three air gap thicknesses of 10 mm, 20 mm and 30 mm were used between the date palm fiber sample and the rigid backing of the impedance tube. The results showed that when facing the palm date fiber sample with perforated plate the sound absorption coefficient improved at the higher and lower frequency ranges. This increase in sound absorption coincided with reduction in medium frequency absorption. However, this could be improved by using different densities or perforated plate with the date palm fiber panel.
A continuous process to align electrospun nanofibers into parallel and crossed arrays
NASA Astrophysics Data System (ADS)
Laudenslager, Michael J.; Sigmund, Wolfgang M.
2013-04-01
Electrical, optical, and mechanical properties of nanofibers are strongly affected by their orientation. Electrospinning is a nanofiber processing technique that typically produces nonwoven meshes of randomly oriented fibers. While several alignment techniques exist, they are only able to produce either a very thin layer of aligned fibers or larger quantities of fibers with less control over their alignment and orientation. The technique presented herein fills the gap between these two methods allowing one to produce thick meshes of highly oriented nanofibers. In addition, this technique is not limited to collection of fibers along a single axis. Modifications to the basic setup allow collection of crossed fibers without stopping and repositioning the apparatus. The technique works for a range of fiber sizes. In this study, fiber diameters ranged from 100 nm to 1 micron. This allows a few fibers at a time to rapidly deposit in alternating directions creating an almost woven structure. These aligned nanofibers have the potential to improve the performance of energy storage and thermoelectric devices and hold great promise for directed cell growth applications.
Development of eddy current probe for fiber orientation assessment in carbon fiber composites
NASA Astrophysics Data System (ADS)
Wincheski, Russell A.; Zhao, Selina
2018-04-01
Measurement of the fiber orientation in a carbon fiber composite material is crucial in understanding the load carrying capability of the structure. As manufacturing conditions including resin flow and molding pressures can alter fiber orientation, verification of the as-designed fiber layup is necessary to ensure optimal performance of the structure. In this work, the development of an eddy current probe and data processing technique for analysis of fiber orientation in carbon fiber composites is presented. A proposed directional eddy current probe is modeled and its response to an anisotropic multi-layer conductor simulated. The modeling results are then used to finalize specifications of the eddy current probe. Experimental testing of the fabricated probe is presented for several samples including a truncated pyramid part with complex fiber orientation draped to the geometry for resin transfer molding. The inductively coupled single sided measurement enables fiber orientation characterization through the thickness of the part. The fast and cost-effective technique can be applied as a spot check or as a surface map of the fiber orientations across the structure. This paper will detail the results of the probe design, computer simulations, and experimental results.
Wang, Jian; Zhou, Pin; Obata, Akiko; Jones, Julian R.; Kasuga, Toshihiro
2015-01-01
In previous works, we reported the fabrication of cotton-wool-like composites consisting of siloxane-doped vaterite and poly(l-lactic acid) (SiVPCs). Various irregularly shaped bone voids can be filled with the composite, which effectively supplies calcium and silicate ions, enhancing the bone formation by stimulating the cells. The composites, however, were brittle and showed an initial burst release of ions. In the present work, to improve the mechanical flexibility and ion release, the composite fiber was coated with a soft, thin layer consisting of poly(d,l-lactic-co-glycolic acid) (PLGA). A coaxial electrospinning technique was used to prepare a cotton-wool-like material comprising “core-shell”-type fibers with a diameter of ~12 µm. The fibers, which consisted of SiVPC coated with a ~2-µm-thick PLGA layer, were mechanically flexible; even under a uniaxial compressive load of 1.5 kPa, the cotton-wool-like material did not exhibit fracture of the fibers and, after removing the load, showed a ~60% recovery. In Tris buffer solution, the initial burst release of calcium and silicate ions from the “core-shell”-type fibers was effectively controlled, and the ions were slowly released after one day. Thus, the mechanical flexibility and ion-release behavior of the composites were drastically improved by the thin PLGA coating. PMID:28793691
In-vivo imaging of retinal nerve fiber layer vasculature: imaging - histology comparison
Scoles, Drew; Gray, Daniel C; Hunter, Jennifer J; Wolfe, Robert; Gee, Bernard P; Geng, Ying; Masella, Benjamin D; Libby, Richard T; Russell, Stephen; Williams, David R; Merigan, William H
2009-01-01
Background Although it has been suggested that alterations of nerve fiber layer vasculature may be involved in the etiology of eye diseases, including glaucoma, it has not been possible to examine this vasculature in-vivo. This report describes a novel imaging method, fluorescence adaptive optics (FAO) scanning laser ophthalmoscopy (SLO), that makes possible for the first time in-vivo imaging of this vasculature in the living macaque, comparing in-vivo and ex-vivo imaging of this vascular bed. Methods We injected sodium fluorescein intravenously in two macaque monkeys while imaging the retina with an FAO-SLO. An argon laser provided the 488 nm excitation source for fluorescence imaging. Reflectance images, obtained simultaneously with near infrared light, permitted precise surface registration of individual frames of the fluorescence imaging. In-vivo imaging was then compared to ex-vivo confocal microscopy of the same tissue. Results Superficial focus (innermost retina) at all depths within the NFL revealed a vasculature with extremely long capillaries, thin walls, little variation in caliber and parallel-linked structure oriented parallel to the NFL axons, typical of the radial peripapillary capillaries (RPCs). However, at a deeper focus beneath the NFL, (toward outer retina) the polygonal pattern typical of the ganglion cell layer (inner) and outer retinal vasculature was seen. These distinguishing patterns were also seen on histological examination of the same retinas. Furthermore, the thickness of the RPC beds and the caliber of individual RPCs determined by imaging closely matched that measured in histological sections. Conclusion This robust method demonstrates in-vivo, high-resolution, confocal imaging of the vasculature through the full thickness of the NFL in the living macaque, in precise agreement with histology. FAO provides a new tool to examine possible primary or secondary role of the nerve fiber layer vasculature in retinal vascular disorders and other eye diseases, such as glaucoma. PMID:19698151
Tear film measurement by optical reflectometry technique
Lu, Hui; Wang, Michael R.; Wang, Jianhua; Shen, Meixiao
2014-01-01
Abstract. Evaluation of tear film is performed by an optical reflectometer system with alignment guided by a galvanometer scanner. The reflectometer system utilizes optical fibers to deliver illumination light to the tear film and collect the film reflectance as a function of wavelength. Film thickness is determined by best fitting the reflectance-wavelength curve. The spectral reflectance acquisition time is 15 ms, fast enough for detecting film thickness changes. Fast beam alignment of 1 s is achieved by the galvanometer scanner. The reflectometer was first used to evaluate artificial tear film on a model eye with and without a contact lens. The film thickness and thinning rate have been successfully quantified with the minimum measured thickness of about 0.3 μm. Tear films in human eyes, with and without a contact lens, have also been evaluated. A high-contrast spectral reflectance signal from the precontact lens tear film is clearly observed, and the thinning dynamics have been easily recorded from 3.69 to 1.31 μm with lipid layer thickness variation in the range of 41 to 67 nm. The accuracy of the measurement is better than ±0.58% of the film thickness at an estimated tear film refractive index error of ±0.001. The fiber-based reflectometer system is compact and easy to handle. PMID:24500519
Effects of HF Treatments on Tensile Strength of Hi-Nicalon Fibers
NASA Technical Reports Server (NTRS)
Bansal, Narottam P.
1998-01-01
Tensile strengths of as-received Hi-Nicalon fibers and those having a dual BN/SiC surface coating, deposited by chemical vapor deposition, have been measured at room temperature. These fibers were also treated with HF for 24 h followed by tensile strength measurements. Strengths of uncoated and BN/SiC coated Hi-Nicalon fibers extracted from celsian matrix composites, by dissolving away the matrix in HF for 24 h, were also determined. The average tensile strength of uncoated Hi-Nicalon was 3.19 +/- 0.73 GPa with a Weibull modulus of 5.41. The Hi-Nicalon/BN/SiC fibers showed an average strength of 3.04 q 0.53 GPa and Weibull modulus of 6.66. After HF treatments, the average strengths of the uncoated and BN/SiC coated Hi-Nicalon fibers were 2.69 +/- 0.67 GPa and 2.80 +/- 0.53 GPa and the Weibull moduli were 4.93 and 5.96, respectively. The BN/SiC coated fibers extracted from the celsian matrix composite exhibited a strength of 2.38 +/- 0.40 GPa and a Weibull modulus of 7.15. The strength of the uncoated Hi-Nicalon fibers in the composite was so severely degraded that they disintegrated into small fragments during extraction with HF. The uncoated fibers probably undergo mechanical surface damage during hot pressing of the composites. Also, the BN layer on the coated fibers acts as a compliant layer which protects the fibers from mechanical damage during composite processing. The elemental composition and thickness of the fiber coatings were deten-nined using scanning Auger analysis. Microstructural analyses of the fibers and the coatings were done by scanning electron microscopy and transmission electron microscopy. Strengths of fibers calculated using average and measured fiber diameters were in good agreement. Thus, the strength of fibers can be evaluated using an average fiber diameter instead of the measured diameter of each filament.
Dilisio, Matthew F.; Miller, Lindsay R.; Higgins, Laurence D.
2014-01-01
Arthroscopic transtendinous techniques for the arthroscopic repair of partial-thickness, articular-surface rotator cuff tears offer the advantage of minimizing the disruption of the patient's remaining rotator cuff tendon fibers. In addition, double-row fixation of full-thickness rotator cuff tears has shown biomechanical advantages. We present a novel method combining these 2 techniques for transtendon, double-row, transosseous-equivalent arthroscopic repair of partial-thickness, articular-surface rotator cuff tears. Direct visualization of the reduction of the retracted articular tendon layer to its insertion on the greater tuberosity is the key to the procedure. Linking the medial-row anchors and using a double-row construct provide a stable repair that allows early shoulder motion to minimize the risk of postoperative stiffness. PMID:25473606
Dilisio, Matthew F; Miller, Lindsay R; Higgins, Laurence D
2014-10-01
Arthroscopic transtendinous techniques for the arthroscopic repair of partial-thickness, articular-surface rotator cuff tears offer the advantage of minimizing the disruption of the patient's remaining rotator cuff tendon fibers. In addition, double-row fixation of full-thickness rotator cuff tears has shown biomechanical advantages. We present a novel method combining these 2 techniques for transtendon, double-row, transosseous-equivalent arthroscopic repair of partial-thickness, articular-surface rotator cuff tears. Direct visualization of the reduction of the retracted articular tendon layer to its insertion on the greater tuberosity is the key to the procedure. Linking the medial-row anchors and using a double-row construct provide a stable repair that allows early shoulder motion to minimize the risk of postoperative stiffness.
NASA Astrophysics Data System (ADS)
Nyssen, Jan; Frankl, Amaury; Pontzeele, Jolien; De Visscher, Maarten; Billi, Paolo
2013-04-01
With the recovery of the European beaver (Castor fiber) and their capacity to engineer fluvial landscapes, questions arise as to how they influence river discharge and sediment transport. The Chevral river (Ardennes, Belgium) contains two beaver dam sequences which appeared in 2004 and count now about 30 dams. Flow discharges and sediment fluxes were measured at the in- and outflow of each dam sequence. Volumes of sediment deposited behind the dams were measured. Between 2004 and 2011, peak flows were topped off, and the magnitude of extreme events decreased. 1710 m³ of sediment were deposited behind the beaver dams, with an average sediment thickness of 25 cm. The thickness of the sediment layer is related to the area of the beaver ponds. Along the stream, beaver pond sediment thickness displayed a sinusoidal deposition pattern, in which ponds with thick sediment layers were preceded by a series of ponds with thinner sediment layers. A downstream textural coarsening in the dam sequences was also observed, probably due to dam failures subsequent to surges. Differences in sediment flux between the in- and outflow at the beaver pond sequence were related to the river hydrograph, with deposition taking place during the rising limbs and slight erosion during the falling limbs. The seven-year-old sequences have filtered 190 tons of sediment out of the Chevral river, which is of the same order of magnitude as the 374 tons measured in pond deposits, with the difference between the values corresponding to beaver excavations (60 tons), inflow from small tributaries, and runoff from the valley flanks. Hydrogeomorphic effects of C. fiber and C. canadensis activity are similar in magnitude. The detailed analysis of changes to hydrology in beaver pond sequences confirms the potential of beavers to contribute to river and wetland restoration and catchment management.
Strained-layer epitaxy of germanium-silicon alloys
NASA Astrophysics Data System (ADS)
Bean, J. C.
1985-10-01
Strained-layer epitaxy is presented as a developing technique for combining Si with other materials in order to obtain semiconductors with enhanced electronic properties. The method involves applying layers sufficiently thin so that the atoms deposited match the bonding configurations of the substrate crystal. When deposited on Si, a four-fold bonding pattern is retained, with a lowered interfacial energy and augmented stored strain energy in the epitaxial layer. The main problem which remains is building an epitaxial layer thick enough to yield desired epitaxial properties while avoiding a reversion to an unstrained structure. The application of a Ge layer to Si using MBE is described, along with the formation of heterojunction multi-layer superlattices, which can reduce the dislocation effects in some homojunctions. The technique shows promise for developing materials of use as bipolar transistors, optical detectors and fiber optic transmission devices.
Araki, Syunsuke; Miki, Atsushi; Goto, Katsutoshi; Yamashita, Tsutomu; Takizawa, Go; Haruishi, Kazuko; Ieki, Yoshiaki; Kiryu, Junichi; Yaoeda, Kiyoshi
2017-09-15
To investigate macular retinal and choroidal thickness in amblyopic eyes compared to that in fellow and normal eyes using swept-source optical coherence tomography (SS-OCT). This study examined 31 patients with hyperopic anisometropic amblyopia (6.9 ± 3.8 years, mean ± standard deviation), 15 patients with strabismic amblyopia without anisometropia (7.9 ± 4.2 years), and 24 age-matched controls (7.8 ± 3.3 years). Retinal and choroidal thickness was measured by 3D scans using SS-OCT. A 6-mm area around the fovea was automatically analyzed using the Early Treatment Diabetic Retinopathy Study map. The thickness from SS-OCT was corrected for magnification error using individual axial length, spherical refraction, cylinder refraction, and corneal radius. Retinal thickness was divided into the macular retinal nerve fiber layer (mRNFL), ganglion cell layer + inner plexiform layer (GCL+IPL), ganglion cell complex (GCC), and the inner limiting membrane to the retinal pigment epithelium (ILM-RPE) thickness. Retinal and choroidal thickness was compared among amblyopic, fellow, and normal eyes. In both amblyopia groups, there was no significant difference in the mRNFL, GCL+IPL, and GCC thicknesses among the amblyopic, fellow, and control eyes. In the anisometropic amblyopia group, choroidal thickness (subfovea, center 1 mm, nasal and inferior of the inner ring, nasal of the outer ring, and center 6 mm) of amblyopic eyes were significantly greater than that of fellow and normal eyes. In contrast, none of the choroidal thicknesses were significantly different among the investigated eyes in the strabismic amblyopia group. We found no significant difference in inner retinal thickness in patients with unilateral amblyopia. Although there were significant differences in choroidal thickness with hyperopic anisometropic amblyopia, there was no significant difference for the strabismic amblyopia. The discrepancy in choroidal thickness between the two types of amblyopia may be due to both differences in ocular size and underlying mechanism.
Duncker, Tobias; Lee, Winston; Jiang, Fan; Ramachandran, Rithambara; Hood, Donald C; Tsang, Stephen H; Sparrow, Janet R; Greenstein, Vivienne C
2018-01-01
To assess structure and function across the transition zone (TZ) between relatively healthy and diseased retina in acute zonal occult outer retinopathy. Six patients (6 eyes; age 22-71 years) with acute zonal occult outer retinopathy were studied. Spectral-domain optical coherence tomography, fundus autofluorescence, near-infrared reflectance, color fundus photography, and fundus perimetry were performed and images were registered to each other. The retinal layers of the spectral-domain optical coherence tomography scans were segmented and the thicknesses of two outer retinal layers, that is, the total receptor and outer segment plus layers, and the retinal nerve fiber layer were measured. All eyes showed a TZ on multimodal imaging. On spectral-domain optical coherence tomography, the TZ was in the nasal retina at varying distances from the fovea. For all eyes, it was associated with loss of the ellipsoid zone band, significant thinning of the two outer retinal layers, and in three eyes with thickening of the retinal nerve fiber layer. On fundus autofluorescence, all eyes had a clearly demarcated peripapillary area of abnormal fundus autofluorescence delimited by a border of high autofluorescence; the latter was associated with loss of the ellipsoid zone band and with a change from relatively normal to markedly decreased or nonrecordable visual sensitivity on fundus perimetry. The results of multimodal imaging clarified the TZ in acute zonal occult outer retinopathy. The TZ was outlined by a distinct high autofluorescence border that correlated with loss of the ellipsoid zone band on spectral-domain optical coherence tomography. However, in fundus areas that seemed healthy on fundus autofluorescence, thinning of the outer retinal layers and thickening of the retinal nerve fiber layer were observed near the TZ. The TZ was also characterized by a decrease in visual sensitivity.
Takayama, Kohei; Ooto, Sotaro; Hangai, Masanori; Arakawa, Naoko; Oshima, Susumu; Shibata, Naohisa; Hanebuchi, Masaaki; Inoue, Takashi; Yoshimura, Nagahisa
2012-01-01
To conduct high-resolution imaging of the retinal nerve fiber layer (RNFL) in normal eyes using adaptive optics scanning laser ophthalmoscopy (AO-SLO). AO-SLO images were obtained in 20 normal eyes at multiple locations in the posterior polar area and a circular path with a 3-4-mm diameter around the optic disc. For each eye, images focused on the RNFL were recorded and a montage of AO-SLO images was created. AO-SLO images for all eyes showed many hyperreflective bundles in the RNFL. Hyperreflective bundles above or below the fovea were seen in an arch from the temporal periphery on either side of a horizontal dividing line to the optic disc. The dark lines among the hyperreflective bundles were narrower around the optic disc compared with those in the temporal raphe. The hyperreflective bundles corresponded with the direction of the striations on SLO red-free images. The resolution and contrast of the bundles were much higher in AO-SLO images than in red-free fundus photography or SLO red-free images. The mean hyperreflective bundle width around the optic disc had a double-humped shape; the bundles at the temporal and nasal sides of the optic disc were narrower than those above and below the optic disc (P<0.001). RNFL thickness obtained by optical coherence tomography correlated with the hyperreflective bundle widths on AO-SLO (P<0.001) AO-SLO revealed hyperreflective bundles and dark lines in the RNFL, believed to be retinal nerve fiber bundles and Müller cell septa. The widths of the nerve fiber bundles appear to be proportional to the RNFL thickness at equivalent distances from the optic disc.
Effects of reuse and bleach/formaldehyde reprocessing on polysulfone and polyamide hemodialyzers.
Cornelius, Rena M; McClung, W Glenn; Barre, Paul; Esguerra, Fe; Brash, John L
2002-01-01
The surface features, morphology, and blood interactions of fibers from pristine, bleach/formaldehyde reprocessed, and reused Fresenius Polysulfone High Flux (Hemoflow F80B) hemodialyzers and Gambro Polyflux 21S Polyamide hemodialyzers have been studied. SEM images of fibers from both hemodialyzer types revealed a dense skin layer on the inner surface and a relatively thick porous layer on the outer surface. The 21S polyamide support layer consisted of interconnected highly porous structures. Environmental scanning electron microscopy and atomic force microscopy images of both membrane types showed alterations in morphology due to reprocessing and reuse; however the changes were more marked for the 21S polyamide dialyzers. Fluorescence microscopy images showed only minimal fluorescence associated with the fibers after patient use and reprocessing, suggesting that blood derived deposits were removed by processing. The protein layers formed on pristine and reused hemodialyzer membranes during clinical use were studied using SDS-PAGE and immunoblotting. Before bleach/formaldehyde treatment, protein layers of considerable amount and complexity were found on the blood side of singly and multiply used dialyzers. Proteins adsorbed on the dialysate side were predominantly in the molecular mass region below 30 kDa. However, some higher molecular mass proteins were detected on the dialysate side of the 21 S polyamide dialyzers. Very little protein was detected on dialyzers that were treated with bleach/formaldehyde after dialysis, regardless of whether they had been used/reprocessed once or 12 times.
2012-01-01
Background To evaluate the influence of corneal astigmatism (CA) on retinal nerve fiber layer (RNFL) thickness and optic nerve head(ONH) parameters measured with spectral-domain optical coherence tomography (OCT) in high myopes patients before refractive surgery. Methods Seventy eyes of 35 consecutive refractive surgery candidates were included in this study. The mean age of the subjects was 26.42 ± 6.95 years, the average CA was −1.17 diopters (D; SD 0.64; range −0.2 to-3.3D), All subjects in this study were WTR CA. 34 eyes were in the normal CA group with a mean CA was −0.67 ± 0.28D, 36 eyes were in the high CA group with an average CA of −1.65 ± 0.49D. All subjects underwent ophthalmic examination and imaging with the Cirrus HD OCT. Results No significant difference was noted in the average cup-to-disk ratio, vertical cup-to-disk ratio and cup volume (all P values > 0.05). Compared with the normal CA group, the high CA group had a larger disc area and rim area, thinner RNFL thickness in the temporal quadrant, and the superotemporal and inferotemporal peaks were farther to the temporal horizon (All P values < 0.05). There were no significant differences between the two groups in global average RNFL thickness, as well as superior, nasal and inferior quadrant RNFL thickness (all P values > 0.05). Conclusions The degree of with-the-rule CA should be considered when interpreting ONH parameters and peripapillary RNFL thickness measured by the Cirrus HD OCT. Virtual slides The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/1148475676881895 PMID:22621341
Kuo, Jane Z.; Zangwill, Linda M.; Medeiros, Felipe A.; Liebmann, Jeffery M.; Girkin, Christopher A.; Hammel, Na’ama; Rotter, Jerome I.; Weinreb, Robert N.
2015-01-01
Purpose To perform a quantitative trait locus (QTL) analysis and evaluate whether a locus between SIX1 and SIX6 is associated with retinal nerve fiber layer (RNFL) thickness in individuals of European descent. Design Observational, multi-center, cross-sectional study. Methods 231 participants were recruited from the Diagnostic Innovations in Glaucoma Study and the African Descent and Glaucoma Evaluation Study. Association of rs10483727 in SIX1-SIX6 with global and sectoral RNFL thickness was performed. Quantitative trait analysis with the additive model of inheritance was analyzed using linear regression. Trend analysis was performed to evaluate the mean global and sectoral RNFL thickness with 3 genotypes of interest (T/T, C/T, C/C). All models were adjusted for age and gender. Results Direction of association between T allele and RNFL thickness was consistent in the global and different sectoral RNFL regions. Each copy of the T risk allele in rs10483727 was associated with −0.16 μm thinner global RNFL thickness (β=−0.16, 95% CI: −0.28 to −0.03; P=0.01). Similar patterns were found for the sectoral regions, including inferior (P=0.03), inferior-nasal (P=0.017), superior-nasal (P=0.0025), superior (P=0.002) and superior-temporal (P=0.008). The greatest differences were observed in the superior and inferior quadrants, supporting clinical observations for RNFL thinning in glaucoma. Thinner global RNFL was found in subjects with T/T genotypes compared to subjects with C/T and C/C genotypes (P=0.044). Conclusions Each copy of the T risk allele has an additive effect and was associated with thinner global and sectoral RNFL. Findings from this QTL analysis further support a genetic contribution to glaucoma pathophysiology. PMID:25849520
Yang, Zi-Jiao; Wei, Jing; Mao, Cheng-Jie; Zhang, Jin-Ru; Chen, Jing; Ji, Xiao-Yan; Liu, Jun-Yi; Shen, Yun; Xiong, Kang-Ping; Huang, Jun-Ying; Yang, Ya-Ping; Liu, Chun-Feng
2016-12-01
Retinal nerve fiber layer (RNFL) thinning occurs in Parkinson's disease (PD) and other neurodegenerative diseases. Idiopathic RBD (iRBD) is a well-established prodromal hallmark of synucleinopathies and occurs secondary to many neurodegenerative diseases, including PD. The aim of this study is to determine whether or not retinal structures are altered with the onset of rapid eye movement (REM) sleep behavior disorders (RBD). In all, a total of 63 patients with PD, 14 patients with idiopathic RBD, and 26 sex- and age-matched healthy controls were enrolled and underwent optical coherence tomography measurements (HD-OCT (Zeiss) ) for the average and every quadrant of RNFL thickness. The REM Sleep Behavior Disorder Screening Questionnaire (RBDSQ) was used to classify PD patients with clinically probable RBD (PD + pRBD) or without probable RBD (PD - pRBD). Patients with iRBD were identified by polysomnography. For patients with RBD (idiopathic or secondary to PD), we found a significant decrease in RNFL thickness compared with groups without RBD (PD - pRBD and healthy controls) (all p < 0.05). Average RNFL thickness in patients with iRBD is significantly thinner than in healthy controls (p < 0.05). In PD, the average RNFL thickness was dramatically thinner in the PD + pRBD group than the PD - pRBD group (p < 0.005). Compared with healthy controls, RNFL thickness was slightly thinner in the drug-naive PD group but not the PD group with drug treatment. Multiple linear regression analysis showed that RBDSQ score was negatively associated with average and inferior RNFL variation in PD (all p < 0.005). The findings show that RNFL was slightly but significantly thinner in idiopathic RBD. In PD, RNFL thickness may vary depending on the presence of RBD.
Ultrasonic Assessment of Impact-Induced Damage and Microcracking in Polymer Matrix Composites
NASA Technical Reports Server (NTRS)
Liaw, Benjamin; Villars, Esther; Delmont, Frantz; Bowles, Kenneth J. (Technical Monitor)
2001-01-01
The main objective of this NASA FAR project is to conduct ultrasonic assessment of impact-induced damage and microcracking in polymer matrix composites at various temperatures. It is believed that the proposed study of impact damage assessment on polymer matrix composites will benefit several NASA missions and current interests, such as ballistic impact testing of composite fan containment and high strain rate deformation modeling of polymer matrix composites. Impact-induced damage mechanisms in GLARE and ARALL fiber-metal laminates subject to instrumented drop-weight impacts at various temperatures were studied. GLARE and ARALL are hybrid composites made of alternating layers of aluminum and glass (for GLARE) and aramid- (for ARALL) fiber-reinforced epoxy. Damage in pure aluminum panels impacted by foreign objects was mainly characterized by large plastic deformation surrounding a deep penetration dent. On the other hand, plastic deformation in fiber-metal laminates was often not as severe although the penetration dent was still produced. The more stiff fiber-reinforced epoxy layers provided better bending rigidity; thus, enhancing impact damage tolerance. Severe cracking, however, occurred due to the use of these more brittle fiber-reinforced epoxy layers. Fracture patterns, e.g., crack length and delamination size, were greatly affected by the lay-up configuration rather than by the number of layers, which implies that thickness effect was not significant for the panels tested in this study. Immersion ultrasound techniques were then used to assess damages generated by instrumented drop-weight impacts onto these fiber-metal laminate panels as well as 6061-T6 aluminum/cast acrylic sandwich plates adhered by epoxy. Depending on several parameters, such as impact velocity, mass, temperature, laminate configuration, sandwich construction, etc., various types of impact damage were observed, including plastic deformation, radiating cracks emanating from the impact site, ring cracks surrounding the impact site, partial and full delamination, and combinations of these damages.
NASA Astrophysics Data System (ADS)
Park, Sung Chang; Lim, Yeong Jin; Lee, Tae-Keun; Kim, Cheol Jin
MgB2/carbon fibers have been synthesized by the combination of RF-sputtering of B and thermal evaporation of Mg, followed by co-evaporation. First, boron layer was deposited by RF-sputtering on the carbon fiber with average diameter of 7.1 μm. Later this coated layer of B was reacted with Mg vapor to transform into MgB2. Since the MgB2 reaction proceed with Mg diffusion into the boron layer, Mg vapor pressure and the diffusion time had to be controlled precisely to secure the complete reaction. Also the deposition rate of each element was controlled separately to obtain stoichiometric MgB2, since Mg was evaporated by thermal heating and B by sputtering system. The sintered B target was magnetron sputtered at the RF-power of ~200 W, which corresponded to the deposition rate of ~3.6 Å/s. With the deposition rate of B fixed, the vapor pressure of Mg was controlled by varying the temperature of tungsten boat with heating element control unit between 100 and 900°C. The MgB2 layers with the thickness of 200-950 nm could be obtained and occasionally MgO appeared as a second phase. Superconducting transition temperatures were measured around ~38 K depending on the deposition condition.
The collagenic architecture of human dura mater.
Protasoni, Marina; Sangiorgi, Simone; Cividini, Andrea; Culuvaris, Gloria Tiffany; Tomei, Giustino; Dell'Orbo, Carlo; Raspanti, Mario; Balbi, Sergio; Reguzzoni, Marcella
2011-06-01
Human dura mater is the most external meningeal sheet surrounding the CNS. It provides an efficient protection to intracranial structures and represents the most important site for CSF turnover. Its intrinsic architecture is made up of fibrous tissue including collagenic and elastic fibers that guarantee the maintenance of its biophysical features. The recent technical advances in the repair of dural defects have allowed for the creation of many synthetic and biological grafts. However, no detailed studies on the 3D microscopic disposition of collagenic fibers in dura mater are available. The authors report on the collagenic 3D architecture of normal dura mater highlighting the orientation, disposition in 3 dimensions, and shape of the collagen fibers with respect to the observed layer. Thirty-two dura mater specimens were collected during cranial decompressive surgical procedures, fixed in 2.5% Karnovsky solution, and digested in 1 N NaOH solution. After a routine procedure, the specimens were observed using a scanning electron microscope. The authors distinguished the following 5 layers in the fibrous dura mater of varying thicknesses, orientation, and structures: bone surface, external median, vascular, internal median, and arachnoid layers. The description of the ultrastructural 3D organization of the different layers of dura mater will give us more information for the creation of synthetic grafts that are as similar as possible to normal dura mater. This description will be also related to the study of the neoplastic invasion.
The structure and function of the macula in patients with advanced retinitis pigmentosa.
Vámos, Rita; Tátrai, Erika; Németh, János; Holder, Graham E; DeBuc, Delia Cabrera; Somfai, Gábor Márk
2011-10-28
To assess the structure and function of the macula in advanced retinitis pigmentosa (RP). Twenty-nine eyes of 22 patients with RP were compared against 17 control eyes. Time-domain optical coherence tomography (OCT) data were processed using OCTRIMA (optical coherence tomography retinal image analysis) as a means of quantifying commercial OCT system images. The thickness of the retinal nerve fiber layer (RNFL), ganglion cell layer and inner plexiform layer complex (GCL+IPL), inner nuclear layer and outer plexiform layer complex (INL+OPL), and the outer nuclear layer (ONL) were measured. Multifocal electroretinography (mfERG) was performed; two groups were formed based on the mfERG findings. Fourteen eyes had no detectable central retinal function (NCRF) on mfERG; detectable but abnormal retinal function (DRF) was present in the mfERG of the other 15 eyes. The thickness of the ONL in the central macular region was significantly less in the NCRF eyes compared with that in both DRF eyes and controls. The ONL was significantly thinner in the pericentral region in both patient groups compared with that in controls, whereas the thickness of the GCL+IPL and INL+OPL was significantly decreased only in the NCRF eyes. The RNFL in the peripheral region was significantly thicker, whereas the thickness of the GCL+IPL and ONL was significantly thinner in both patient groups compared with that in controls. The results are consistent with degeneration of the outer retina preceding inner retinal changes in RP. OCT image segmentation enables objective evaluation of retinal structural changes in RP, with potential use in the planning of therapeutic interventions and conceivably as an outcome measure.
The Structure and Function of the Macula in Patients with Advanced Retinitis Pigmentosa
Vámos, Rita; Tátrai, Erika; Németh, János; Holder, Graham E.; DeBuc, Delia Cabrera
2011-01-01
Purpose. To assess the structure and function of the macula in advanced retinitis pigmentosa (RP). Methods. Twenty-nine eyes of 22 patients with RP were compared against 17 control eyes. Time-domain optical coherence tomography (OCT) data were processed using OCTRIMA (optical coherence tomography retinal image analysis) as a means of quantifying commercial OCT system images. The thickness of the retinal nerve fiber layer (RNFL), ganglion cell layer and inner plexiform layer complex (GCL+IPL), inner nuclear layer and outer plexiform layer complex (INL+OPL), and the outer nuclear layer (ONL) were measured. Multifocal electroretinography (mfERG) was performed; two groups were formed based on the mfERG findings. Fourteen eyes had no detectable central retinal function (NCRF) on mfERG; detectable but abnormal retinal function (DRF) was present in the mfERG of the other 15 eyes. Results. The thickness of the ONL in the central macular region was significantly less in the NCRF eyes compared with that in both DRF eyes and controls. The ONL was significantly thinner in the pericentral region in both patient groups compared with that in controls, whereas the thickness of the GCL+IPL and INL+OPL was significantly decreased only in the NCRF eyes. The RNFL in the peripheral region was significantly thicker, whereas the thickness of the GCL+IPL and ONL was significantly thinner in both patient groups compared with that in controls. Conclusions. The results are consistent with degeneration of the outer retina preceding inner retinal changes in RP. OCT image segmentation enables objective evaluation of retinal structural changes in RP, with potential use in the planning of therapeutic interventions and conceivably as an outcome measure. PMID:21948552
Lee, Sang-Yoon; Lee, Eun Kyoung; Park, Ki Ho; Kim, Dong Myung; Jeoung, Jin Wook
2016-01-01
To report an asymmetry analysis of macular inner retinal layers using swept-source optical coherence tomography (OCT) and to evaluate the utility for glaucoma diagnosis. Observational, cross-sectional study. Seventy normal healthy subjects and 62 glaucoma patients. Three-dimensional scans were acquired from 70 normal subjects and 62 open angle glaucoma patients by swept-source OCT. The thickness of the retinal nerve fiber layer, ganglion cell-inner plexiform layer (GCIPL), ganglion cell complex, and total retina were calculated within a 6.2×6.2 mm macular area divided into a 31×31 grid of 200×200 μm superpixels. For each of the corresponding superpixels, the thickness differences between the subject eyes and contra-lateral eyes and between the upper and lower macula halves of the subject eyes were determined. The negative differences were displayed on a gray-scale asymmetry map. Black superpixels were defined as thickness decreases over the cut-off values. The negative inter-ocular and inter-hemisphere differences in GCIPL thickness (mean ± standard deviation) were -2.78 ± 0.97 μm and -3.43 ± 0.71 μm in the normal group and -4.26 ± 2.23 μm and -4.88 ± 1.46 μm in the glaucoma group. The overall extent of the four layers' thickness decrease was larger in the glaucoma group than in the normal group (all Ps<0.05). The numbers of black superpixels on all of the asymmetry maps were larger in the glaucoma group than in the normal group (all Ps<0.05). The area under receiver operating characteristic curves of average negative thickness differences in macular inner layers for glaucoma diagnosis ranged from 0.748 to 0.894. The asymmetry analysis of macular inner retinal layers showed significant differences between the normal and glaucoma groups. The diagnostic performance of the asymmetry analysis was comparable to that of previous methods. These findings suggest that the asymmetry analysis can be a potential ancillary diagnostic tool.
Arsenic sulfide layers for dielectric reflection mirrors prepared from solution
NASA Astrophysics Data System (ADS)
Matějec, Vlastimil; Pedlikova, Jitka; BartoÅ, Ivo; Podrazký, Ondřej
2017-12-01
Chalcogenide materials due to high refractive indices, transparency in the mid-IR spectral region, nonlinear refractive indices, etc, have been employed as fibers and films in different photonic devices such as light amplifiers, optical regenerators, broadband radiation sources. Chalcogenide films can be prepared by physical methods as well as by solution-based techniques in which solutions of chalcogenides in amines are used. This paper presents results on the solution-based fabrication and optical characterization of single arsenic sulfide layers and multilayer stacks containing As2S3 layers together with porous silica layers coated on planar and fiber-optic substrates. Input As2S3 solutions for the layer fabrications were prepared by dissolving As2S3 powder in n-propylamine in a concentration of 0.50 mol/l. These solutions were applied on glass slides by dip-coating method and obtained layers were thermally treated in vacuum at temperatures up to 180 °C. Similar procedure was used for As2S3 layers in multilayer stacks. Such stacks were fabricated by repeating the application of one porous silica layer prepared by the sol-gel method and one As2S3 layer onto glass slides or silica fibers (a diameter of 0.3 mm) by using the dip-coating method. It has been found that the curing process of the applied layers has to be carefully controlled in order to obtain stacks with three pairs of such layers. Single arsenic and porous silica layers were characterized by optical microscopy, and by measuring their transmission spectra in a range of 200-2500 nm. Thicknesses and refractive indices were estimated from the spectra. Transmission spectra of planar multilayer stacks were measured, too. Interference bands have been determined from optical measurements on the multilayer stacks with a minimum transmittance of about 50% which indicates the possibility of using such stacks as reflecting mirrors.
NASA Astrophysics Data System (ADS)
Wu, Sigang; Dai, Hongzhe; Wang, Wei
2007-12-01
This paper designs an innovative reinforced concrete (RC) beam strengthened with carbon fiber reinforced concrete (CFRC) composites. Six groups of test beams, five with different degrees of strengthening, achieved by changing the location and the thickness of the CFRC layer, and one virgin RC beam, were tested in four-point bending over a span of 3000 mm. We investigate the effect of the CFRC layer on the flexural performance and the electrical properties of the designed beams. The test results indicate that the CFRC strengthened RC beam exhibits improved electrical properties as well as better mechanical performance. Also, the location and the thickness of the CFRC layer affect the initial electrical resistance and other electrical properties of the beam. Relationships between electrical resistance, loading, deflection and cracks show that the increase in the electrical resistance can be used to monitor the extent of damage to the designed beam. Based on this discovery, a new health monitoring technique for RC structures is produced by means of electrical resistance measurements.
Wrenn, Jr., George E.; Holcombe, Jr., Cressie E.
1988-01-01
A multilayered thermal insulating composite is formed of a first layer of zirconia-bonded zirconia fibers for utilization near the hot phase or surface of a furnace or the like. A second layer of zirconia-bonded metal oxide fibers is attached to the zirconia fiber layer by a transition layer formed of intermingled zirconia fibers and metal oxide fibers. The thermal insulation is fabricated by vacuum molding with the layers being sequentially applied from aqueous solutions containing the fibers to a configured mandrel. A portion of the solution containing the fibers forming the first layer is intermixed with the solution containing the fibers of the second layer for forming the layer of mixed fibers. The two layers of fibers joined together by the transition layer are saturated with a solution of zirconium oxynitrate which provides a zirconia matrix for the composite when the fibers are sintered together at their nexi.
Wrenn, G.E. Jr.; Holcombe, C.E. Jr.
1988-09-13
A multilayered thermal insulating composite is formed of a first layer of zirconia-bonded zirconia fibers for utilization near the hot phase or surface of a furnace or the like. A second layer of zirconia-bonded metal oxide fibers is attached to the zirconia fiber layer by a transition layer formed of intermingled zirconia fibers and metal oxide fibers. The thermal insulation is fabricated by vacuum molding with the layers being sequentially applied from aqueous solutions containing the fibers to a configured mandrel. A portion of the solution containing the fibers forming the first layer is intermixed with the solution containing the fibers of the second layer for forming the layer of mixed fibers. The two layers of fibers joined together by the transition layer are saturated with a solution of zirconium oxynitrate which provides a zirconia matrix for the composite when the fibers are sintered together at their nexi.
Effects of Intracranial Trochlear Neurectomy on the Structure of the Primate Superior Oblique Muscle
Poukens, Vadims; Ying, Howard; Shan, Xiaoyan; Tian, Jing; Zee, David S.
2010-01-01
Purpose. Although cyclovertical strabismus in humans is frequently attributed to superior oblique (SO) palsy, anatomic effects of SO denervation have not been studied. Magnetic resonance imaging (MRI) and orbital histology was used to study the effects of acute trochlear (CN4) denervation on the monkey SO. Methods. Five juvenile macaque monkeys were perfused with formalin for 5 weeks: 15 months after unilateral or bilateral 10-mm intracranial trochlear neurectomy. Denervated and fellow orbits were imaged by MRI, embedded whole in paraffin, serially sectioned at 10-μm thickness, and stained with Masson trichrome. Whole muscle and individual fiber cross sections were quantified in SO muscles throughout the orbit and traced larger fibers in one specimen where they were present. Results. MRI demonstrated marked reduction in midorbital cross section in denervated SO muscles, with anterior shift of SO mass preserving overall volume. Muscle fibers exhibited variable atrophy along their lengths. Denervated orbital layer (OL) fiber cross sections were slightly but significantly reduced from control at most anteroposterior locations, but this reduction was much more profound in global layer (GL) fibers. Intraorbital and intramuscular CN4 were uniformly fibrotic. In one animal, there were scattered clusters of markedly hypertrophic GL fibers that exhibited only sparse myomyous junctions only anteriorly. Conclusions. CN4 denervation produces predominantly SO GL atrophy with relative OL sparing. Overall midorbital SO atrophy was evident by MRI as early as 5 weeks after denervation, as denervated SO volume shifted anteriorly. Occasional GL fiber hypertrophy suggests that at least some SO fibers extend essentially the full muscle length after trochlear neurectomy. PMID:20164458
Chiang, Chia-Chin; Li, Chein-Hsing
2014-06-02
In the present study, a novel packaged long-period fiber grating (PLPFG) strain sensor is first presented. The MEMS process was utilized to fabricate the packaged optical fiber strain sensor. The sensor structure consisted of etched optical fiber sandwiched between two layers of thick photoresist SU-8 3050 and then packaged with poly (dimethylsiloxane) (PDMS) polymer material to construct the PLPFG strain sensor. The PDMS packaging material was used to prevent the glue effect, wherein glue flows into the LPFG structure and reduces coupling strength, in the surface bonding process. Because the fiber grating was packaged with PDMS material, it was effectively protected and made robust. The resonance attenuation dip of PLPFG grows when it is loading. This study explored the size effect of the grating period and fiber diameter of PLPFG via tensile testing. The experimental results found that the best strain sensitivity of the PLPFG strain sensor was -0.0342 dB/με, and that an R2 value of 0.963 was reached.
A low-cost, high-yield fabrication method for producing optimized biomimetic dry adhesives
NASA Astrophysics Data System (ADS)
Sameoto, D.; Menon, C.
2009-11-01
We present a low-cost, large-scale method of fabricating biomimetic dry adhesives. This process is useful because it uses all photosensitive polymers with minimum fabrication costs or complexity to produce molds for silicone-based dry adhesives. A thick-film lift-off process is used to define molds using AZ 9260 photoresist, with a slow acting, deep UV sensitive material, PMGI, used as both an adhesion promoter for the AZ 9260 photoresist and as an undercutting material to produce mushroom-shaped fibers. The benefits to this process are ease of fabrication, wide range of potential layer thicknesses, no special surface treatment requirements to demold silicone adhesives and easy stripping of the full mold if process failure does occur. Sylgard® 184 silicone is used to cast full sheets of biomimetic dry adhesives off 4" diameter wafers, and different fiber geometries are tested for normal adhesion properties. Additionally, failure modes of the adhesive during fabrication are noted and strategies for avoiding these failures are discussed. We use this fabrication method to produce different fiber geometries with varying cap diameters and test them for normal adhesion strengths. The results indicate that the cap diameters relative to post diameters for mushroom-shaped fibers dominate the adhesion properties.
Shimada, K; Takeshige, N; Moriyama, H; Miyauchi, Y; Shimada, S; Fujimaki, E
1997-12-01
In this study, we clarified the distribution of elastic and oxytalan fibers in a human sternoclavicular joint (SCJ) using a color image system and in extracellular matrices using immunoperoxidase staining. Fine elastic fibers (EFs) were scattered in the fibrous layer of the sternoclavicular disk. This articular disk was composed of a collagenous bundle on the sternum side of the articular disk in the SCJ and cellular components including connective tissue on the clavicular side of the articular disk. The thickness of the disk gradually increased from the inferior to superior portion. Collagen fibers type I, III and V and other extracellular matrices (ECMs) were detected in the hypertrophic zone in the clavicular and sternum side of the SCJ and in the connective tissue of the articulatio condylar. On the cervical surface of the articular disk, cellular activity was higher than on the sternum surface.
Fahmy, Rania M; Bhat, Ramesa S; Al-Mutairi, Manar; Aljaser, Feda S; El-Ansary, Afaf
2018-01-01
Objective To evaluate the effect of diabetes mellitus (DM), diabetic retinopathy, and degree of glycemic control (glycosylated hemoglobin [HbA1c]) on peripapillary retinal nerve fiber layer thickness (RNFLT) using optical coherence tomography. Methods The study included 126 eyes of healthy controls (n=32) and diabetics patients (n=31), whose ages ranged from 40 to 70 years. The diabetic group was divided into: Subgroup 1: with HbA1c <7% and Subgroup 2: with HbA1c ≥7%. All patients underwent full ophthalmic examination. HbA1c level was obtained with the A1cNow+ system and the peripapillary RNFLT was measured using 3D-OCT 2000 Topcon (360-degree circular scan with 3.4 mm diameter centered on optic disc). Results The obtained data demonstrates significant decrease in peripapillary RNFLT in superior and inferior quadrants of the right eye (p=0.000 and p=0.039, respectively), and in superior quadrant of the left eye (p=0.002) with impairment of glycemic control. Pearson’s correlation test showed significant negative correlation of RNFLT with HbA1c in the superior quadrant in both eyes. Conclusion Impairment of glycemic control affects the peripapillary RNFLT mainly in the superior quadrant. This thickness also tends to decrease with long-standing DM, use of DM medications, and development of diabetic retinopathy. The measurement of peripapillary RNFLT may become a useful method to monitor early retinal changes in diabetic patients. PMID:29535499
Comparison of macular OCTs in right and left eyes of normal people
NASA Astrophysics Data System (ADS)
Mahmudi, Tahereh; Kafieh, Rahele; Rabbani, Hossein; Mehri dehnavi, Alireza; Akhlagi, Mohammadreza
2014-03-01
Retinal 3D Optical coherence tomography (OCT) is a non-invasive imaging modality in ocular diseases. Due to large volumes of OCT data, it is better to utilize automatic extraction of information from OCT images, such as total retinal thickness and retinal nerve fiber layer thickness (RNFLT). These two thickness values have become useful indices to indicate the progress of diseases like glaucoma, according to the asymmetry between two eyes of an individual. Furthermore, the loss of ganglion cells may not be diagnosable by other tests and even not be evaluated when we only consider the thickness of one eye (due to dramatic different thickness among individuals). This can justify our need to have a comparison between thicknesses of two eyes in symmetricity. Therefore, we have proposed an asymmetry analysis of the retinal nerve layer thickness and total retinal thickness around the macula in the normal Iranian population. In the first step retinal borders are segmented by diffusion map method and thickness profiles were made. Then we found the middle point of the macula by pattern matching scheme. RNFLT and retinal thickness are analyzed in 9 sectors and the mean and standard deviation of each sector in the right and left eye are obtained. The maximums of the average RNFL thickness in right and left eyes are seen in the perifoveal nasal, and the minimums are seen in the fovea. Tolerance limits in RNFL thickness is shown to be between 0.78 to 2.4 μm for 19 volunteers used in this study.
Hood, Donald C
2007-05-01
Glaucoma causes damage to the retinal ganglion cells and their axons, and this damage can be detected with both structural and functional tests. The purpose of this study was to better understand the relationship between a structural measure of retinal nerve fiber layer (RNFL) and the most common functional test, behavioral sensitivity with static automated perimetry (SAP). First, a linear model, previously shown to describe the relationship between local visual evoked potentials and SAP sensitivity, was modified to predict the change in RNFL as measured by optical coherence tomography. Second, previous work by others was shown to be consistent with this model.
Listgarten, M A; Buser, D; Steinemann, S G; Donath, K; Lang, N P; Weber, H P
1992-02-01
This experiment was aimed at studying the intact tissue/implant interface of non-submerged dental implants with a titanium surface. Epoxy-resin replicas were fabricated from 3.05 x 8 mm cylindrical titanium implants with a plasma-sprayed apical portion and a smooth coronal collar. The replicas were coated with a 90-120-nm-thick layer of pure titanium and autoclaved. The coated replicas were inserted as non-submerged endosseous implants in the edentulous premolar region of dog mandibles and allowed to heal for three months. Jaw sections containing the implants were processed for light and electron microscopic study of the intact tissue/implant interface with and without prior demineralization. Gingival connective tissue fibers were closely adapted to the titanium layer, in an orientation more or less parallel to the implant surface. There was no evidence of any fiber insertions into the surface irregularities of the smooth or rough titanium surface. Undemineralized bone was intimately adapted to the titanium surface without any intervening space. In demineralized sections, the collagen fibers of the bone matrix tended to be somewhat thinner and occasionally less densely packed in the vicinity of the implant surface. However, they extended all the way to the titanium surface, without any intervening fibril-free layer.
Tan, Yu Jun; Tan, Xipeng; Yeong, Wai Yee; Tor, Shu Beng
2016-11-03
Polymeric fibrous scaffolds for guiding cell growth are designed to be potentially used for the tissue engineering (TE) of tubular organs including esophagi, blood vessels, tracheas, etc. Tubular scaffolds were fabricated via melt-drawing of highly elastic poly(l-lactide-co-ε-caprolactone) (PLC) fibers layer-by-layer on a cylindrical mandrel. The diameter and length of the scaffolds are customizable via 3D printing of the mandrel. Thickness of the scaffolds was varied by changing the number of layers of the melt-drawing process. The morphology and tensile properties of the PLC fibers were investigated. The fibers were highly aligned with a uniform diameter. Their diameters and tensile properties were tunable by varying the melt-drawing speeds. These tailorable topographies and tensile properties show that the additive-based scaffold fabrication technique is customizable at the micro- and macro-scale for different tubular tissues. The merits of these scaffolds in TE were further shown by the finding that myoblast and fibroblast cells seeded onto the scaffolds in vitro showed appropriate cell proliferation and distribution. Human mesenchymal stem cells (hMSCs) differentiated to smooth muscle lineage on the microfibrous scaffolds in the absence of soluble induction factors, showing cellular shape modulation and scaffold elasticity may encourage the myogenic differentiation of stem cells.
Free Vibration of Fiber Composite Thin Shells in a Hot Environment
NASA Technical Reports Server (NTRS)
Gotsis, Pascal K.; Guptill, James D.
1995-01-01
Results are presented of parametric studies to assess the effects of various parameters on the free vibration behavior (natural frequencies) of (plus or minus theta)2, angle-ply fiber composite thin shells in a hot environment. These results were obtained by using a three-dimensional finite element structural analysis computer code. The fiber composite shell is assumed to be cylindrical and made from T-300 graphite fibers embedded in an intermediate-modulus high-strength matrix (IMHS). The residual stresses induced into the laminated structure during curing are taken into account. The following parameters are investigated: the length and the thickness of the shell, the fiber orientations, the fiber volume fraction, the temperature profile through the thickness of the laminate and the different ply thicknesses. Results obtained indicate that: the fiber orientations and the length of the laminated shell had significant effect on the natural frequencies. The fiber volume fraction, the laminate thickness and the temperature profile through the shell thickness had a weak effect on the natural frequencies. Finally, the laminates with different ply thicknesses had insignificant influence on the behavior of the vibrated laminated shell.
Bertucci, Alessandro; Manicardi, Alex; Candiani, Alessandro; Giannetti, Sara; Cucinotta, Annamaria; Spoto, Giuseppe; Konstantaki, Maria; Pissadakis, Stavros; Selleri, Stefano; Corradini, Roberto
2015-01-15
Microstructured optical fibers containing microchannels and Bragg grating inscribed were internally functionalized with a peptide nucleic acid (PNA) probe specific for a gene tract of the genetically modified Roundup Ready soy. These fibers were used as an optofluidic device for the detection of DNA by measuring the shift in the wavelength of the reflected IR light. Enhancement of optical read-out was obtained using streptavidin coated gold-nanoparticles interacting with the genomic DNA captured in the fiber channels (0%, 0.1%, 1% and 10% RR-Soy), enabling to achieve statistically significant, label-free, and amplification-free detection of target DNA in low concentrations, low percentages, and very low sample volumes. Computer simulations of the fiber optics based on the finite element method (FEM) were consistent with the formation of a layer of organic material with an average thickness of 39 nm for the highest percentage (10% RR soy) analysed. Copyright © 2014 Elsevier B.V. All rights reserved.
Knight, O'Rese J; Girkin, Christopher A; Budenz, Donald L; Durbin, Mary K; Feuer, William J
2012-03-01
To determine the effect of race, demographic, and ocular variables on optic nerve head and retinal nerve fiber layer (RNFL) thickness measurements using spectral-domain optical coherence tomography. In a cross-sectional observational study, 284 normal subjects aged 18 to 84 years were evaluated at 7 sites using Cirrus HD-OCT. Disc area, rim area, average cup-disc ratio, vertical cup-disc ratio, cup volume, and average, temporal, superior, nasal, and inferior RNFL thicknesses were calculated. The main outcome measures were associations between Cirrus HD-OCT optic nerve head and RNFL measurements and age, sex, and race. The 284 subjects self-identified as being of European (122), Chinese (63), African (51), or Hispanic (35) descent. After adjusting for the effect of age, there was a statistically significant difference among racial groups for all optic nerve head and RNFL parameters (all P ≤ .005) except rim area (P = .22). Rim area, average cup-disc ratio, vertical cup-disc ratio, and cup volume were moderately associated with disc area (r(2) = 0.15, 0.33, 0.33, and 0.37, respectively). After a linear adjustment for disc area, there was no statistically significant difference among racial groups for any optic nerve head parameter. Individuals of European descent had thinner RNFL measurements except in the temporal quadrant. There are racial differences in optic disc area, average cup-disc ratio, vertical cup-disc ratio, cup volume, and RNFL thickness as measured by Cirrus HD-OCT. These differences should be considered when using Cirrus HD-OCT to assess for glaucomatous damage in differing population groups.
Knight, O’Rese J.; Girkin, Christopher A.; Budenz, Donald L.; Durbin, Mary K.; Feuer, William J.
2017-01-01
Objective To determine the effect of race, demographic, and ocular variables on optic nerve head and retinal nerve fiber layer (RNFL) thickness measurements using spectral-domain optical coherence tomography. Methods In a cross-sectional observational study, 284 normal subjects aged 18 to 84 years were evaluated at 7 sites using Cirrus HD-OCT. Disc area, rim area, average cup-disc ratio, vertical cup-disc ratio, cup volume, and average, temporal, superior, nasal, and inferior RNFL thicknesses were calculated. The main outcome measures were associations between Cirrus HD-OCT optic nerve head and RNFL measurements and age, sex, and race. Results The 284 subjects self-identified as being of European (122), Chinese (63), African (51), or Hispanic (35) descent. After adjusting for the effect of age, there was a statistically significant difference among racial groups for all optic nerve head and RNFL parameters (all P≤.005) except rim area (P=.22). Rim area, average cup-disc ratio, vertical cup-disc ratio, and cup volume were moderately associated with disc area (r2=0.15, 0.33, 0.33, and 0.37, respectively). After a linear adjustment for disc area, there was no statistically significant difference among racial groups for any optic nerve head parameter. Individuals of European descent had thinner RNFL measurements except in the temporal quadrant. Conclusions There are racial differences in optic disc area, average cup-disc ratio, vertical cup-disc ratio, cup volume, and RNFL thickness as measured by Cirrus HD-OCT. These differences should be considered when using Cirrus HD-OCT to assess for glaucomatous damage in differing population groups. PMID:22411660
Moon, Byung Gil; Cho, Jung Woo; Kang, Sung Yong; Yun, Sung-Cheol; Na, Jung Hwa; Lee, Youngrok; Kook, Michael S.
2012-01-01
Purpose To evaluate the use of scanning laser polarimetry (SLP, GDx VCC) to measure the retinal nerve fiber layer (RNFL) thickness in order to evaluate the progression of glaucoma. Methods Test-retest measurement variability was determined in 47 glaucomatous eyes. One eye each from 152 glaucomatous patients with at least 4 years of follow-up was enrolled. Visual field (VF) loss progression was determined by both event analysis (EA, Humphrey guided progression analysis) and trend analysis (TA, linear regression analysis of the visual field index). SLP progression was defined as a reduction of RNFL exceeding the predetermined repeatability coefficient in three consecutive exams, as compared to the baseline measure (EA). The slope of RNFL thickness change over time was determined by linear regression analysis (TA). Results Twenty-two eyes (14.5%) progressed according to the VF EA, 16 (10.5%) by VF TA, 37 (24.3%) by SLP EA and 19 (12.5%) by SLP TA. Agreement between VF and SLP progression was poor in both EA and TA (VF EA vs. SLP EA, k = 0.110; VF TA vs. SLP TA, k = 0.129). The mean (±standard deviation) progression rate of RNFL thickness as measured by SLP TA did not significantly differ between VF EA progressors and non-progressors (-0.224 ± 0.148 µm/yr vs. -0.218 ± 0.151 µm/yr, p = 0.874). SLP TA and EA showed similar levels of sensitivity when VF progression was considered as the reference standard. Conclusions RNFL thickness as measurement by SLP was shown to be capable of detecting glaucoma progression. Both EA and TA of SLP showed poor agreement with VF outcomes in detecting glaucoma progression. PMID:22670073
Moon, Byung Gil; Sung, Kyung Rim; Cho, Jung Woo; Kang, Sung Yong; Yun, Sung-Cheol; Na, Jung Hwa; Lee, Youngrok; Kook, Michael S
2012-06-01
To evaluate the use of scanning laser polarimetry (SLP, GDx VCC) to measure the retinal nerve fiber layer (RNFL) thickness in order to evaluate the progression of glaucoma. Test-retest measurement variability was determined in 47 glaucomatous eyes. One eye each from 152 glaucomatous patients with at least 4 years of follow-up was enrolled. Visual field (VF) loss progression was determined by both event analysis (EA, Humphrey guided progression analysis) and trend analysis (TA, linear regression analysis of the visual field index). SLP progression was defined as a reduction of RNFL exceeding the predetermined repeatability coefficient in three consecutive exams, as compared to the baseline measure (EA). The slope of RNFL thickness change over time was determined by linear regression analysis (TA). Twenty-two eyes (14.5%) progressed according to the VF EA, 16 (10.5%) by VF TA, 37 (24.3%) by SLP EA and 19 (12.5%) by SLP TA. Agreement between VF and SLP progression was poor in both EA and TA (VF EA vs. SLP EA, k = 0.110; VF TA vs. SLP TA, k = 0.129). The mean (±standard deviation) progression rate of RNFL thickness as measured by SLP TA did not significantly differ between VF EA progressors and non-progressors (-0.224 ± 0.148 µm/yr vs. -0.218 ± 0.151 µm/yr, p = 0.874). SLP TA and EA showed similar levels of sensitivity when VF progression was considered as the reference standard. RNFL thickness as measurement by SLP was shown to be capable of detecting glaucoma progression. Both EA and TA of SLP showed poor agreement with VF outcomes in detecting glaucoma progression.
Hood, Donald C; Chen, Monica F; Lee, Dongwon; Epstein, Benjamin; Alhadeff, Paula; Rosen, Richard B; Ritch, Robert; Dubra, Alfredo; Chui, Toco Y P
2015-04-01
To improve our understanding of glaucomatous damage as seen on circumpapillary disc scans obtained with frequency-domain optical coherence tomography (fdOCT), fdOCT scans were compared to images of the peripapillary retinal nerve fiber (RNF) bundles obtained with an adaptive optics-scanning light ophthalmoscope (AO-SLO). The AO-SLO images and fdOCT scans were obtained on 6 eyes of 6 patients with deep arcuate defects (5 points ≤-15 db) on 10-2 visual fields. The AO-SLO images were montaged and aligned with the fdOCT images to compare the RNF bundles seen with AO-SLO to the RNF layer thickness measured with fdOCT. All 6 eyes had an abnormally thin (1% confidence limit) RNF layer (RNFL) on fdOCT and abnormal (hyporeflective) regions of RNF bundles on AO-SLO in corresponding regions. However, regions of abnormal, but equal, RNFL thickness on fdOCT scans varied in appearance on AO-SLO images. These regions could be largely devoid of RNF bundles (5 eyes), have abnormal-appearing bundles of lower contrast (6 eyes), or have isolated areas with a few relatively normal-appearing bundles (2 eyes). There also were local variations in reflectivity of the fdOCT RNFL that corresponded to the variations in AO-SLO RNF bundle appearance. Relatively similar 10-2 defects with similar fdOCT RNFL thickness profiles can have very different degrees of RNF bundle damage as seen on fdOCT and AO-SLO. While the results point to limitations of fdOCT RNFL thickness as typically analyzed, they also illustrate the potential for improving fdOCT by attending to variations in local intensity.
Aleman, Tomas S.; Huang, Jiayan; Garrity, Sean T.; Carter, Stuart B.; Aleman, Wendy D.; Ying, Gui-shuang; Tamhankar, Madhura A.
2014-01-01
Purpose To study the relationship between the appearance of the optic nerve and the retinal nerve fiber layer (RNFL) thickness determined by spectral domain optical coherence tomography (OCT). Methods Records from patients with spectral domain-OCT imaging in a neuro-ophthalmology practice were reviewed. Eyes with glaucoma/glaucoma suspicion, macular/optic nerve edema, pseudophakia, and with refractive errors > 6D were excluded. Optic nerve appearance by slit lamp biomicroscopy was related to the RNFL thickness by spectral domain-OCT and to visual field results. Results Ninety-one patients (176 eyes; mean age: 49 ± 15 years) were included. Eighty-three eyes (47%) showed optic nerve pallor; 89 eyes (50.6%) showed RNFL thinning (sectoral or average peripapillary). Average peripapillary RNFL thickness in eyes with pallor (mean ± SD = 76 ± 17 μm) was thinner compared to eyes without pallor (91 ± 14 μm, P < 0.001). Optic nerve pallor predicted RNFL thinning with a sensitivity of 69% and a specificity of 75%. Optic nerve appearance predicted RNFL thinning (with a sensitivity and specificity of 81%) when RNFL had thinned by ∼ 40%. Most patients with pallor had RNFL thinning with (66%) or without (25%) visual field loss; the remainder had normal RNFL and fields (5%) or with visual field abnormalities (4%). Conclusions Optic nerve pallor as a predictor of RNFL thinning showed fair sensitivity and specificity, although it is optimally sensitive/specific only when substantial RNFL loss has occurred. Translational Relevance Finding an acceptable relationship between the optic nerve appearance by ophthalmoscopy and spectral domain-OCT RNFL measures will help the clinician's interpretation of the information provided by this technology, which is gaining momentum in neuro-ophthalmic research. PMID:25374773
Chansangpetch, Sunee; Huang, Guofu; Coh, Paul; Oldenburg, Catherine; Amoozgar, Behzad; He, Mingguang; Lin, Shan C
2018-04-01
To compare optic nerve head, peripapillary retinal nerve fiber layer (pRNFL), and ganglion cell complex (GCC) parameters between Caucasian and ethnic Chinese. Normal subjects above 40 years old and self-identified as being Caucasian and Chinese were recruited. They were evaluated with spectral-domain optical coherence tomography (RTVue-100). Parameters related to the optic nerve head, pRNFL, and GCC analysis protocols were acquired. Multivariable linear regression was performed adjusting for potential confounders. Data from 116 Caucasian and 130 Chinese subjects were available for analysis. Mean age of all participants was 66.72 (SD 10.82) years. There were statistically significant differences for disc area (DA), area cup-to-disc, vertical cup-to-disc, and cup volume (P=0.02, 0.004, 0.02, and 0.03, respectively), greater in Chinese. After adjusting for age, sex, axial length (AL), intraocular pressure (IOP), DA, and GCC thickness, Chinese subjects had significantly greater thickness in all pRNFL parameters (mean differences ranged between 4.29 and 9.93 μm; all P<0.001) except the nasal quadrant. GCC outcomes were also adjusted for DA and pRNFL; Caucasians had significantly higher average GCC and inferior GCC (mean difference 2.97 and 3.45 μm, respectively; P<0.01), whereas the Chinese group had significantly higher ganglion cell global loss volume (mean difference 2.47 %, P<0.001). This study suggests there is significantly greater pRNFL thickness in Chinese, which were independent of age, AL, IOP, and DA, and possibly greater GCC in Caucasians after adjustment for age, AL, IOP, DA, and pRNFL thickness.
Effects of Laser Wavelength on Ablator Testing
NASA Technical Reports Server (NTRS)
White, Susan M.
2014-01-01
Wavelength-dependent or spectral radiation effects are potentially significant for thermal protection materials. NASA atmospheric entry simulations include trajectories with significant levels of shock layer radiation which is concentrated in narrow spectral lines. Tests using two different high powered lasers, the 10.6 micron LHMEL I CO2 laser and the near-infrared 1.07 micron fiber laser, on low density ablative thermal protection materials offer a unique opportunity to evaluate spectral effects. Test results indicated that the laser wavelength can impact the thermal response of an ablative material, in terms of bond-line temperatures, penetration times, mass losses, and char layer thicknesses.
NASA Astrophysics Data System (ADS)
Qi, Yadong; Bai, Shuju; Vogelmann, Thomas C.; Heisler, Gordon M.
2003-11-01
The depth of light penetration from the adaxial surfaces of the mature leaves of pecan (Carya illinoensis) was measured using a fiber optic microprobe system at four wavelengths: UV-B (310nm), UV-A (360 nm), blue light (430nm), and red light (680nm). The average thickness of the leaf adaxial epidermal layer was 15um and the total leaf thickness was 219um. The patterns of the light attenuation by the leaf tissues exhibited strong wavelength dependence. The leaf adaxial epidermal layer was chiefly responsible for absorbing the UV-A UV-B radiation. About 98% of 310 nm light was steeply attenuated within the first 5 um of the adaxial epidermis; thus, very little UV-B radiation was transmitted to the mesophyll tissues where contain photosynthetically sensitive sites. The adaxial epidermis also attenuated 96% of the UV-A radiation. In contrast, the blue and red light penetrated much deeper and was gradually attenutated by the leaves. The mesophyll tissues attenuated 17% of the blue light and 42% of the red light, which were available for photosynthesis use. Since the epidermal layer absorbed nearly all UV-B light, it acted as an effective filter screening out the harmful radiation and protecting photosynthetically sensitive tissues from the UV-B damage. Therefore, the epidermal function of the UV-B screening effectiveness can be regarded as one of the UV-B protection mechanisms in pecan.
Lleó-Pérez, A; Ortuño-Soto, A; Rahhal, M S; Martínez-Soriano, F; Sanchis-Gimeno, J A
2004-01-01
To evaluate quantitatively the intraobserver reproducibility of measurements of the retinal nerve fiber layer (RNFL) in healthy subjects and an ocular hypertensive population using two nerve fiber analyzers. Sixty eyes of normal (n=30) and ocular hypertensive subjects (n=30) were consecutively recruited for this study and underwent a complete ophthalmologic examination and achromatic automated perimetry. RNFL were measured using scanning laser polarimeter (GDx-VCC) and optical coherence tomography (OCT Model 3000). Reproducibility of the RNFL measurements obtained with both nerve fiber analyzers were compared using the coefficient of variation. In both groups the authors found fair correlations between the two methods in all ratio and thickness parameters. The mean coefficient of variation for measurement of the variables ranged from 2.24% to 13.12% for GDx-VCC, and from 5.01% to 9.24% for OCT Model 3000. The authors could not detect any significant differences between healthy and ocular hypertensive eyes, although in normal eyes the correlations improved slightly. Nevertheless, the test-retest correlation was slightly better for GDx-VCC than for OCT Model 3000 (5.55% and 7.11%, respectively). Retinal mapping software of both nerve fiber analyzers allows reproducible measurement of RNFL in both healthy subjects and ocular hypertensive eyes, and shows fair correlations and good intraobserver reproducibility. However, in our study, GDx showed a better test-retest correlation.
NASA Astrophysics Data System (ADS)
Bao, Yi; Cain, John; Chen, Yizheng; Huang, Ying; Chen, Genda; Palek, Leonard
2015-04-01
Thin concrete panels reinforced with alloy polymer macro-synthetic fibers have recently been introduced to rapidly and cost-effectively improve the driving condition of existing roadways by laying down a fabric sheet on the roadways, casting a thin layer of concrete, and then cutting the layer into panels. This study is aimed to understand the strain distribution and potential crack development of concrete panels under three-point loading. To this end, six full-size 6ft×6ft×3in concrete panels were tested to failure in the laboratory. They were instrumented with three types of single-mode optical fiber sensors whose performance and ability to measure the strain distribution and detect cracks were compared. Each optical fiber sensor was spliced and calibrated, and then attached to a fabric sheet using adhesive. A thin layer of mortar (0.25 ~ 0.5 in thick) was cast on the fabric sheet. The three types of distributed sensors were bare SM-28e+ fiber, SM-28e+ fiber with a tight buffer, and concrete crack cable, respectively. The concrete crack cable consisted of one SM-28e+ optical fiber with a tight buffer, one SM-28e+ optical fiber with a loose buffer for temperature compensation, and an outside protective tight sheath. Distributed strains were collected from the three optical fiber sensors with pre-pulse-pump Brillouin optical time domain analysis in room temperature. Among the three sensors, the bare fiber was observed to be most fragile during construction and operation, but most sensitive to strain change or micro-cracks. The concrete crack cable was most rugged, but not as sensitive to micro-cracks and robust in micro-crack measurement as the bare fiber. The ruggedness and sensitivity of the fiber with a tight buffer were in between the bare fiber and the concrete crack cable. The strain distribution resulted from the three optical sensors are in good agreement, and can be applied to successfully locate cracks in the concrete panels. It was observed that the three types of fibers were functional until the concrete panels have experienced inelastic deformation, making the distributed strain sensing technology promising for real applications in pavement engineering.
USDA-ARS?s Scientific Manuscript database
The thickness of cotton fiber cell walls is an important property that partially determines the economic value of cotton. To better understand the physical and chemical manifestations of the genetic variations that regulate the degree of fiber wall thickness, we used a comprehensive set of methods t...
Stemplewitz, Birthe; Kromer, Robert; Vettorazzi, Eik; Hidding, Ute; Frings, Andreas; Buhmann, Carsten
2017-07-13
This cross-sectional study compared the retinal morphology between patients with progressive supranuclear palsy (PSP) and healthy controls. (The retinal nerve fiber layer (RNFL) around the optic disc and the retina in the macular area of 22 PSP patients and 151 controls were investigated by spectral domain optical coherence tomography (SD-OCT). Additionally, the RNFL and the nerve fiber index (NFI) were measured by scanning laser polarimetry (SLP). Results of RNFL measurements with SD-OCT and SLP were compared to assess diagnostic discriminatory power. Applying OCT, PSP patients showed a smaller RNFL thickness in the inferior nasal and inferior temporal areas. The macular volume and the thickness of the majority of macular sectors were reduced compared to controls. SLP data showed a thinner RNFL thickness and an increase in the NFI in PSP patients. Sensitivity and specificity to discriminate PSP patients from controls were higher applying SLP than SD-OCT. Retinal changes did not correlate with disease duration or severity in any OCT or SLP measurement. PSP seems to be associated with reduced thickness and volume of the macula and reduction of the RNFL, independent of disease duration or severity. Retinal imaging with SD-OCT and SLP might become an additional tool in PSP diagnosis.
Age, ocular magnification, and circumpapillary retinal nerve fiber layer thickness
NASA Astrophysics Data System (ADS)
Wang, Mengyu; Elze, Tobias; Li, Dian; Baniasadi, Neda; Wirkner, Kerstin; Kirsten, Toralf; Thiery, Joachim; Loeffler, Markus; Engel, Christoph; Rauscher, Franziska G.
2017-12-01
Optical coherence tomography (OCT) manufacturers graphically present circumpapillary retinal nerve fiber layer thickness (cpRNFLT) together with normative limits to support clinicians in diagnosing ophthalmic diseases. The impact of age on cpRNFLT is typically implemented by linear models. cpRNFLT is strongly location-specific, whereas previously published norms are typically restricted to coarse sectors and based on small populations. Furthermore, OCT devices neglect impacts of lens or eye size on the diameter of the cpRNFLT scan circle so that the diameter substantially varies over different eyes. We investigate the impact of age and scan diameter reported by Spectralis spectral-domain OCT on cpRNFLT in 5646 subjects with healthy eyes. We provide cpRNFLT by age and diameter at 768 angular locations. Age/diameter were significantly related to cpRNFLT on 89%/92% of the circle, respectively (pointwise linear regression), and to shifts in cpRNFLT peak locations. For subjects from age 42.1 onward but not below, increasing age significantly decreased scan diameter (r=-0.28, p<0.001), which suggests that pathological cpRNFLT thinning over time may be underestimated in elderly compared to younger subjects, as scan diameter decrease correlated with cpRNFLT increase. Our detailed numerical results may help to generate various correction models to improve diagnosing and monitoring optic neuropathies.
Han, Mei; Zhao, Chen; Han, Quan-Hong; Xie, Shiyong; Li, Yan
2016-08-01
To examine the changes of non-arteritic anterior ischemic optic neuropathy (NAION) by serial morphometry using Fourier domain optical coherence tomography (FD-OCT). Retrospective study in patients with newly diagnosed NAION (n=33, all unilateral) and controls (n=75 unilateral NAION patients with full contralateral eye vision) who underwent FD-OCT of the optic disk, optic nerve head (ONH), and macula within 1 week of onset and again 1, 3, 6, and 12 months later. The patients showed no improvement in vision during follow-up. Within 1 week of onset, all NAION eyes exhibited severe ONH fiber crowding and peripapillary retinal nerve fiber layer (RNFL) edema. Four had subretinal fluid accumulation and 12 had posterior vitreous detachment (PVD) at the optic disc surface. Ganglion cell complex (GCC) and RNFL thicknesses were reduced at 1 and 3 months (p < 0.05), with no deterioration thereafter. Initial RNFL/GCC contraction magnitude in the superior hemisphere correlated with the severity of inferior visual field deficits. NAION progression is characterized by an initial phase of accelerated RNFL and GCC deterioration. These results reveal that the kinetic change of neural retina in NAION and may have implication on the time window for treatment of NAION. FD-OCT is useful in the evaluation of NAION.
Bowd, Christopher; Medeiros, Felipe A.; Zhang, Zuohua; Zangwill, Linda M.; Hao, Jiucang; Lee, Te-Won; Sejnowski, Terrence J.; Weinreb, Robert N.; Goldbaum, Michael H.
2010-01-01
Purpose To classify healthy and glaucomatous eyes using relevance vector machine (RVM) and support vector machine (SVM) learning classifiers trained on retinal nerve fiber layer (RNFL) thickness measurements obtained by scanning laser polarimetry (SLP). Methods Seventy-two eyes of 72 healthy control subjects (average age = 64.3 ± 8.8 years, visual field mean deviation =−0.71 ± 1.2 dB) and 92 eyes of 92 patients with glaucoma (average age = 66.9 ± 8.9 years, visual field mean deviation =−5.32 ± 4.0 dB) were imaged with SLP with variable corneal compensation (GDx VCC; Laser Diagnostic Technologies, San Diego, CA). RVM and SVM learning classifiers were trained and tested on SLP-determined RNFL thickness measurements from 14 standard parameters and 64 sectors (approximately 5.6° each) obtained in the circumpapillary area under the instrument-defined measurement ellipse (total 78 parameters). Tenfold cross-validation was used to train and test RVM and SVM classifiers on unique subsets of the full 164-eye data set and areas under the receiver operating characteristic (AUROC) curve for the classification of eyes in the test set were generated. AUROC curve results from RVM and SVM were compared to those for 14 SLP software-generated global and regional RNFL thickness parameters. Also reported was the AUROC curve for the GDx VCC software-generated nerve fiber indicator (NFI). Results The AUROC curves for RVM and SVM were 0.90 and 0.91, respectively, and increased to 0.93 and 0.94 when the training sets were optimized with sequential forward and backward selection (resulting in reduced dimensional data sets). AUROC curves for optimized RVM and SVM were significantly larger than those for all individual SLP parameters. The AUROC curve for the NFI was 0.87. Conclusions Results from RVM and SVM trained on SLP RNFL thickness measurements are similar and provide accurate classification of glaucomatous and healthy eyes. RVM may be preferable to SVM, because it provides a Bayesian-derived probability of glaucoma as an output. These results suggest that these machine learning classifiers show good potential for glaucoma diagnosis. PMID:15790898
Novakova, Lenka; Axelsson, Markus; Malmeström, Clas; Imberg, Henrik; Elias, Olle; Zetterberg, Henrik; Nerman, Olle; Lycke, Jan
2018-01-01
Neurodegeneration occurs during the early stages of multiple sclerosis. It is an essential, devastating part of the pathophysiology. Tools for measuring the degree of neurodegeneration could improve diagnostics and patient characterization. This study aimed to determine the diagnostic value of biomarkers of degeneration in patients with recent clinical onset of suspected multiple sclerosis, and to evaluate these biomarkers for characterizing disease course. This cross-sectional study included 271 patients with clinical features of suspected multiple sclerosis onset and was the baseline of a prospective study. After diagnostic investigations, the patients were classified into the following disease groups: patients with clinically isolated syndrome (n = 4) or early relapsing remitting multiple sclerosis (early RRMS; n = 93); patients with relapsing remitting multiple sclerosis with disease durations ≥2 years (established RRMS; n = 39); patients without multiple sclerosis, but showing symptoms (symptomatic controls; n = 89); and patients diagnosed with other diseases (n = 46). In addition, we included healthy controls (n = 51) and patients with progressive multiple sclerosis (n = 23). We analyzed six biomarkers of neurodegeneration: cerebrospinal fluid neurofilament light chain levels; cerebral spinal fluid glial fibrillary acidic protein; cerebral spinal fluid tau; retinal nerve fiber layer thickness; macula volume; and the brain parenchymal fraction. Except for increased cerebral spinal fluid neurofilament light chain levels, median 670 ng/L (IQR 400-2110), we could not find signs of early degeneration in the early disease group with recent clinical onset. However, the intrathecal immunoglobin G production and cerebral spinal fluid neurofilament light chain levels showed diagnostic value. Moreover, elevated levels of cerebral spinal fluid glial fibrillary acidic protein, thin retinal nerve fiber layers, and low brain parenchymal fractions were associated with progressive disease, but not with the other phenotypes. Thin retinal nerve fiber layers and low brain parenchymal fractions, which indicated neurodegeneration, were associated with longer disease duration. In clinically suspected multiple sclerosis, intrathecal immunoglobin G production and neurofilament light chain levels had diagnostic value. Therefore, these biomarkers could be included in diagnostic work-ups for multiple sclerosis. We found that the thickness of the retinal nerve fiber layer and the brain parenchymal fraction were not different between individuals that were healthy, symptomatic, or newly diagnosed with multiple sclerosis. This finding suggested that neurodegeneration had not reached a significant magnitude in patients with a recent clinical onset of multiple sclerosis.
Lee, Sang-Yoon; Lee, Eun Kyoung; Park, Ki Ho; Kim, Dong Myung
2016-01-01
Purpose To report an asymmetry analysis of macular inner retinal layers using swept-source optical coherence tomography (OCT) and to evaluate the utility for glaucoma diagnosis. Design Observational, cross-sectional study. Participants Seventy normal healthy subjects and 62 glaucoma patients. Methods Three-dimensional scans were acquired from 70 normal subjects and 62 open angle glaucoma patients by swept-source OCT. The thickness of the retinal nerve fiber layer, ganglion cell-inner plexiform layer (GCIPL), ganglion cell complex, and total retina were calculated within a 6.2×6.2 mm macular area divided into a 31×31 grid of 200×200 μm superpixels. For each of the corresponding superpixels, the thickness differences between the subject eyes and contra-lateral eyes and between the upper and lower macula halves of the subject eyes were determined. The negative differences were displayed on a gray-scale asymmetry map. Black superpixels were defined as thickness decreases over the cut-off values. Results The negative inter-ocular and inter-hemisphere differences in GCIPL thickness (mean ± standard deviation) were -2.78 ± 0.97 μm and -3.43 ± 0.71 μm in the normal group and -4.26 ± 2.23 μm and -4.88 ± 1.46 μm in the glaucoma group. The overall extent of the four layers’ thickness decrease was larger in the glaucoma group than in the normal group (all Ps<0.05). The numbers of black superpixels on all of the asymmetry maps were larger in the glaucoma group than in the normal group (all Ps<0.05). The area under receiver operating characteristic curves of average negative thickness differences in macular inner layers for glaucoma diagnosis ranged from 0.748 to 0.894. Conclusions The asymmetry analysis of macular inner retinal layers showed significant differences between the normal and glaucoma groups. The diagnostic performance of the asymmetry analysis was comparable to that of previous methods. These findings suggest that the asymmetry analysis can be a potential ancillary diagnostic tool. PMID:27764166
Jeong, Jae Hoon; Choi, Yun Jeong; Park, Ki Ho; Kim, Dong Myung; Jeoung, Jin Wook
2016-01-01
To evaluate the effect of multiple covariates on the diagnostic performance of the Cirrus high-definition optical coherence tomography (HD-OCT) for glaucoma detection. A prospective case-control study was performed and included 173 recently diagnosed glaucoma patients and 63 unaffected individuals from the Macular Ganglion Cell Imaging Study. Regression analysis of receiver operating characteristic were conducted to evaluate the influence of age, spherical equivalent, axial length, optic disc size, and visual field index on the macular ganglion cell-inner plexiform layer (GCIPL) and peripapillary retinal nerve fiber layer (RNFL) measurements. Disease severity, as measured by visual field index, had a significant effect on the diagnostic performance of all Cirrus HD-OCT parameters. Age, axial length and optic disc size were significantly associated with diagnostic accuracy of average peripapillary RNFL thickness, whereas axial length had a significant effect on the diagnostic accuracy of average GCIPL thickness. Diagnostic performance of the Cirrus HD-OCT may be more accurate in the advanced stages of glaucoma than at earlier stages. A smaller optic disc size was significantly associated with improved the diagnostic ability of average RNFL thickness measurements; however, GCIPL thickness may be less affected by age and optic disc size.
Comparison of RNFL thickness and RPE-normalized RNFL attenuation coefficient for glaucoma diagnosis
NASA Astrophysics Data System (ADS)
Vermeer, K. A.; van der Schoot, J.; Lemij, H. G.; de Boer, J. F.
2013-03-01
Recently, a method to determine the retinal nerve fiber layer (RNFL) attenuation coefficient, based on normalization on the retinal pigment epithelium, was introduced. In contrast to conventional RNFL thickness measures, this novel measure represents a scattering property of the RNFL tissue. In this paper, we compare the RNFL thickness and the RNFL attenuation coefficient on 10 normal and 8 glaucomatous eyes by analyzing the correlation coefficient and the receiver operator curves (ROCs). The thickness and attenuation coefficient showed moderate correlation (r=0.82). Smaller correlation coefficients were found within normal (r=0.55) and glaucomatous (r=0.48) eyes. The full separation between normal and glaucomatous eyes based on the RNFL attenuation coefficient yielded an area under the ROC (AROC) of 1.0. The AROC for the RNFL thickness was 0.9875. No statistically significant difference between the two measures was found by comparing the AROC. RNFL attenuation coefficients may thus replace current RNFL thickness measurements or be combined with it to improve glaucoma diagnosis.
FIBER AND INTEGRATED OPTICS: Bandgap modes in a coupled waveguide array
NASA Astrophysics Data System (ADS)
Usievich, B. A.; Nurligareev, D. Kh; Svetikov, V. V.; Sychugov, V. A.
2009-08-01
This work examines a waveguide array that consists of ten Nb2O5/SiO2 double layers and supports a 0.63-μm surface wave. The deposition of a Nb2O5 capping layer on top of the waveguide array enables a marked increase in the wave field intensity on its surface. The efficiency of surface-wave excitation in the Kretschmann configuration can be optimised by adjusting the number of double layers. We analyse the behaviour of the Bragg mode in relation to the thickness of the layer exposed to air and the transition of this mode from the second allowed band to the first through the bandgap of the system. In addition, the conventional leaky mode converts to a surface mode and then to a guided mode.
Metal matrix coated fiber composites and the methods of manufacturing such composites
Weeks, Jr., Joseph K.; Gensse, Chantal
1993-01-01
A fiber coating which allows ceramic or metal fibers to be wetted by molten metals is disclosed. The coating inhibits degradation of the physical properties caused by chemical reaction between the fiber and the coating itself or between the fiber and the metal matrix. The fiber coating preferably includes at least a wetting layer, and in some applications, a wetting layer and a barrier layer between the fiber and the wetting layer. The wetting layer promotes fiber wetting by the metal matrix. The barrier layer inhibits fiber degradation. The fiber coating permits the fibers to be infiltrated with the metal matrix resulting in composites having unique properties not obtainable in pure materials.
Metal matrix coated fiber composites and the methods of manufacturing such composites
Weeks, J.K. Jr.; Gensse, C.
1993-09-14
A fiber coating which allows ceramic or metal fibers to be wetted by molten metals is disclosed. The coating inhibits degradation of the physical properties caused by chemical reaction between the fiber and the coating itself or between the fiber and the metal matrix. The fiber coating preferably includes at least a wetting layer, and in some applications, a wetting layer and a barrier layer between the fiber and the wetting layer. The wetting layer promotes fiber wetting by the metal matrix. The barrier layer inhibits fiber degradation. The fiber coating permits the fibers to be infiltrated with the metal matrix resulting in composites having unique properties not obtainable in pure materials. 8 figures.
X-ray microtomography and laser ablation in the analysis of ink distribution in coated paper
DOE Office of Scientific and Technical Information (OSTI.GOV)
Myllys, M., E-mail: markko.myllys@jyu.fi; Häkkänen, H.; Korppi-Tommola, J.
A novel method was developed for studying the ink-paper interface and the structural variations of a deposited layer of ink. Combining high-resolution x-ray tomography with laser ablation, the depth profile of ink (toner), i.e., its varying thickness, could be determined in a paper substrate. X-ray tomography was used to produce the 3D structure of paper with about 1 μm spatial resolution. Laser ablation combined with optical imaging was used to produce the 3D structure of the printed layer of ink on top of that paper with about 70 nm depth resolution. Ablation depth was calibrated with an optical profilometer. It can bemore » concluded that a toner layer on a light-weight-coated paper substrate was strongly perturbed by protruding fibers of the base paper. Such fibers together with the surface topography of the base paper seem to be the major factors that control the leveling of toner and its penetration into a thinly coated paper substrate.« less
NASA Astrophysics Data System (ADS)
Zhu, Caigang; Liu, Quan
2011-08-01
The accurate understanding of optical properties of human tissues plays an important role in the optical diagnosis of early epithelial cancer. Many inverse models used to determine the optical properties of a tumor have assumed that the tumor was semi-infinite, which infers infinite width and length but finite thickness. However, this simplified assumption could lead to large errors for small tumor, especially at the early stages. We used a modified Monte Carlo code, which is able to simulate light transport in a layered tissue model with buried tumor-like targets, to investigate the validity of the semi-infinite tumor assumption in two common epithelial tissue models: a squamous cell carcinoma (SCC) tissue model and a basal cell carcinoma (BCC) tissue model. The SCC tissue model consisted of three layers, i.e. the top epithelium, the middle tumor and the bottom stroma. The BCC tissue model also consisted of three layers, i.e. the top epidermis, the middle tumor and the bottom dermis. Diffuse reflectance was simulated for two common fiber-optic probes. In one probe, both source and detector fibers were perpendicular to the tissue surface; while in the other, both fibers were tilted at 45 degrees relative to the normal axis of the tissue surface. It was demonstrated that the validity of the semi-infinite tumor model depends on both the fiber-optic probe configuration and the tumor dimensions. Two look-up tables, which relate the validity of the semi-infinite tumor model to the tumor width in terms of the source-detector separation, were derived to guide the selection of appropriate tumor models and fiber optic probe configuration for the optical diagnosis of early epithelial cancers.
NASA Astrophysics Data System (ADS)
Hosseini, S. M. A.; Baran, I.; Akkerman, R.
2018-05-01
The laser-assisted tape winding (LATW) is an automated process for manufacturing fiber-reinforced thermoplastic tubular products, such as pipes and pressure vessels. Multi-physical phenomena such as heat transfer, mechanical bonding, phase changes and solid mechanics take place during the process. These phenomena need to be understood and described well for an improved product reliability. Temperature is one of the important parameters in this process to control and optimize the product quality which can be employed in an intelligent model-based inline control system. The incoming tape can overlap with the already wounded layer during the process based on the lay-up configuration. In this situation, the incoming tape can step-on or step-off to an already deposited layer/laminate. During the overlapping, the part temperature changes due to the variation of the geometry caused by previously deposited layer, i.e. a bump geometry. In order to qualify the temperature behavior at the bump regions, an experimental set up is designed on a flat laminate. Artificial bumps/steps are formed on the laminate with various thicknesses and fiber orientations. As the laser head experiences the step-on and step-off, the IR (Infra-Red) camera and the embedded thermocouples measure the temperature on the surface and inside the laminate, respectively. During the step-on, a small drop in temperature is observed while in step-off a higher peak in temperature is observed. It can be concluded that the change in the temperature during overlapping is due to the change in laser incident angle made by the bump geometry. The effect of the step thickness on the temperature peak is quantified and found to be significant.
One-dimensional nanowires of pseudoboehmite (aluminum oxyhydroxide γ-AlOOH)
Iijima, Sumio; Yumura, Takashi; Liu, Zheng
2016-01-01
We report the discovery of a 1D crystalline structure of aluminum oxyhydroxide. It was found in a commercial product of fibrous pseudoboehmite (PB), γ-AlOOH, synthesized easily with low cost. The thinnest fiber found was a ribbon-like structure of only two layers of an Al–O octahedral double sheet having a submicrometer length along its c axis and 0.68-nm thickness along its b axis. This thickness is only slightly larger than half of the lattice parameter of the b-axis unit cell of the boehmite crystal (b/2 = 0.61 nm). Moreover, interlayer splittings having an average width of 1 nm inside the fibrous PB are found. These wider interlayer spaces may have intercalation of water, which is suggested by density functional theory (DFT) calculation. The fibers appear to grow as almost isolated individual filaments in aqueous Al-hydroxide sols and the growth direction of fibrous PB is always along its c axis. PMID:27708158
Secondary polymer layered impregnated tile
NASA Technical Reports Server (NTRS)
Tran, Huy K. (Inventor); Rasky, Daniel J. (Inventor); Szalai, Christine E. (Inventor); Carroll, Joseph A. (Inventor); Hsu, Ming-ta S. (Inventor)
2005-01-01
A low density organic polymer impregnated preformed fibrous ceramic article includes a plurality of layers. A front layer includes ceramic fibers or carbon fibers or combinations of ceramic fibers and carbon fibers, and is impregnated with an effective amount of at least one organic polymer. A middle layer includes polymer impregnated ceramic fibers. A back layer includes ceramic fibers or carbon fibers or combinations of ceramic fibers and carbon fibers, and is impregnated with an effective amount of at least one low temperature pyrolyzing organic polymer capable of decomposing without depositing residues.
Influence of earlobe thickness on near infrared spectroscopy
NASA Astrophysics Data System (ADS)
Jiang, Jingying; Wang, Tianpei; Li, Si; Li, Lin; Liu, Jiajia; Xu, Kexin
2017-03-01
Near-infrared spectroscopy has been recognized as a potential technology for noninvasive blood glucose sensing. However, the detected spectral signal is unstable mainly because of (1) the weak light absorption of glucose itself within NIR range, (2) the influence of temperature and individual differences of biotissue. Our previous results demonstrated that the synergistic effect of both transmittance and reflectance could enhance the strength of the detection signal. In this talk, we design a set of experiments to analyze the effect of earlobe thickness on Near Infrared spectroscopic measurement by using home-made optical fiber probe within the wavelength of 1000-1600nm. Firstly, we made a MC simulation of single-layer skin model and five-layer skin model to get the diffused transmittance spectra and diffused reflectance spectra under different optaical path lengths. And then we obtain the spectra of the earlobes from different volunteers by the same way. The experimental results showed that with the increase of the thickness,the light intensity of diffused transmittance decreases, and the light intensity of diffused reflectance remaines substantially unchanged.
NASA Astrophysics Data System (ADS)
Anggoro, Didi Dwi; Kristiana, Nunung
2015-12-01
Ballistic protection equipment, such as a bulletproof vest, is a soldier's most important means of preserving life and survivability in extreme combat conditions. The bulletproof vests are designed to protect the user's chest from injury without disturbing the ability to perform his duties. Aromatic polyamide or aramid fibers known under the trade name Kevlar, Trawon and so is synthetic fiber materials commonly used in the manufacture of bulletproof vests. This synthetic fibers have high tensile strength and ductility. Kevlar is expensive and imported material. In this study, will introduce local natural raw materials, ramie fiber (Boehmeria nivea) which is cheaper and environmentally friendly. It has enough tenacity and tensile strength as a bulletproof vest. This experiment uses two panels, there are Panel A as front surface of Panel B. Panel A is a combination of ramie and epoxide matrix, while panel B is only ramie. From several variations of experimental combinations between Panel A and Panel B, optimal combination obtained with 16 layers of panel A and 31-34 layers of panel B which is able to protect againts cal. 7.65 mm × 17 mm (.32 ACP) bullet fired through pistol .32 Pindad from a distance of 20 meters. Panel with a size of 20 cm × 20 cm has a total thickness between 12,922 to13,745 mm and a total weight between 506,26 to 520,926gram. Scanning electron microscopy (SEM) observations indicated that the porosity and surface area of the ramie fiber is smooth, fiber surfaces showed topography with micropores. SEM also showed well-arranged structure of fibers bonding. Energy Dispersive X-ray (EDX) analysis indicated 100 % carbon contents in ramie fiber. Test result indicates that panel from composite ramie-epoxide can reach the level 1of International Standard of NIJ - 010104. Compared to panel from polyester fiber, the panel from composite ramie-epoxide (0,50-0,52 kg) is lighter weight than panel polyester fiber (1,642 kg).
NASA Astrophysics Data System (ADS)
Yang, Zhiyong; Tang, Zhanwen; Xie, Yongjie; Shi, Hanqiao; Zhang, Boming; Guo, Hongjun
2018-02-01
Composite space mirror can completely replicate the high-precision surface of mould by replication process, but the actual surface accuracy of the replication composite mirror always decreases. Lamina thickness of prepreg affects the layers and layup sequence of composite space mirror, and which would affect surface accuracy of space mirror. In our research, two groups of contrasting cases through finite element analyses (FEA) and comparative experiments were studied; the effect of different lamina thicknesses of prepreg and corresponding lay-up sequences was focused as well. We describe a special analysis model, validated process and result analysis. The simulated and measured surface figures both get the same conclusion. Reducing lamina thickness of prepreg used in replicating composite space mirror is propitious to optimal design of layup sequence for fabricating composite mirror, and could improve its surface accuracy.
Shin, Jungwoo; Ryu, Won-Hee; Park, Kyu-Sung; Kim, Il-Doo
2013-08-27
Two distinctive one-dimensional (1-D) carbon nanofibers (CNFs) encapsulating irregularly and homogeneously segregated SnCo nanoparticles were synthesized via electrospinning of polyvinylpyrrolidone (PVP) and polyacrylonitrile (PAN) polymers containing Sn-Co acetate precursors and subsequent calcination in reducing atmosphere. CNFs synthesized with PVP, which undergoes structural degradation of the polymer during carbonization processes, exhibited irregular segregation of heterogeneous alloy particles composed of SnCo, Co3Sn2, and SnO with a size distribution of 30-100 nm. Large and exposed multiphase SnCo particles in PVP-driven amorphous CNFs (SnCo/PVP-CNFs) kept decomposing liquid electrolyte and were partly detached from CNFs during cycling, leading to a capacity fading at the earlier cycles. The closer study of solid electrolyte interphase (SEI) layers formed on the CNFs reveals that the gradual growth of fiber radius due to continuous increment of SEI layer thickness led to capacity fading. In contrast, SnCo particles in PAN-driven CNFs (SnCo/PAN-CNFs) showed dramatically reduced crystallite sizes (<10 nm) of single phase SnCo nanoparticles which were entirely embedded in dense, semicrystalline, and highly conducting 1-D carbon matrix. The growth of SEI layer was limited and saturated during cycling. As a result, SnCo/PAN-CNFs showed much improved cyclability (97.9% capacity retention) and lower SEI layer thickness (86 nm) after 100 cycles compared to SnCo/PVP-CNFs (capacity retention, 71.9%; SEI layer thickness, 593 nm). This work verifies that the thermal behavior of carbon precursor is highly responsible for the growth mechanism of SEI layer accompanied with particles detachment and cyclability of alloy particle embedded CNFs.
Synthesis of boron nitride coatings on quartz fibers: Thickness control and mechanism research
NASA Astrophysics Data System (ADS)
Zheng, Yu; Wang, Shubin
2011-10-01
Boron nitride (BN) coatings were successfully synthesized on quartz fibers by dip-coating in boric acid and urea solutions at 700 °C. The SEM micrographs indicated that the quartz fibers were fully covered by coatings with smooth surface. The XRD, FT-IR, XPS spectra and HR-TEM results showed that the composition of the coatings which combined closely with the quartz fibers was polycrystalline h-BN. By changing the dip circles, the coating thickness was well controlled. The thicknesses of samples dipped less than six circles increased linearly with dipping-circles; and the increment of coating thickness would slow down when the fibers were dipped 10 circles. After being dipped for 10 circles, the thickness was about 300 nm. The coating thickness was also established by calculation and the calculated results were consistent with the results measured by micrograph.
Zargarian, S Sh; Haddadi-Asl, V
2017-08-01
Hybrid scaffolds prepared by blend electrospinning of Polycaprolactone and Pluronic solution benefit from enhanced fiber hydrophilicity and may offer satisfactory cell attachment and proliferation. To improve hybrid scaffold wettability and water swelling ratio, adequate amount of hydrophilic polymer is required; though this amount is limited by fiber surface enrichment of Pluronic and cannot be exceeded without affecting the scaffold mechanical properties. To overcome this problem, a routine blend electrospinning setup was modified by exposing the blend solution to water in order to attract Pluronic chains toward the surface of the charged jet. Morphology of scaffolds produced by the routine blend electrospinning and modified method was studied. A 50 nm thick Pluronic layer with linty appearance on the surface of the fibers fabricated by the modified method was detected. Drug-loaded fibers from modified method showed a moderate initial burst and then a prolonged release period while an abnormal two-stage phased release profile was observed for the routine blend method. The latter was associated to Pluronic/drug accumulations within the fibers fabricated by the routine method which resulted in fiber disintegration and a subsequent second burst release.
Permeable polyaniline articles for gas separation
Wang, Hsing-Lin [Los Alamos, NM; Mattes, Benjamin R [Santa Fe, NM
2009-07-21
Immersion precipitation of solutions having 15%-30% (w/w) and various molecular weights of the emeraldine base form of polyaniline in polar aprotic solvents are shown to form integrally skinned asymmetric membranes and fibers having skin layers <1 .mu.m thick which exhibit improved rates of gas transport while preserving good selectivity. These membranes can be further transformed by an acid doping process after fabrication to achieve excellent permeation rates and high selectivities for particular gas separations. Prior to the use of concentrated EB solutions, the formation of integrally skinned asymmetric membranes was not possible, since films and fibers made from <5% w/w polyaniline solutions were found to disintegrate during the IP process.
Permeable polyaniline articles for gas separation
Wang, Hsing-Lin; Mattes, Benjamin R.
2004-09-28
Immersion precipitation of solutions having 15%-30% (w/w) and various molecular weights of the emeraldine base form of polyaniline in polar aprotic solvents are shown to form integrally skinned asymmetric membranes and fibers having skin layers <1 .mu.m thick which exhibit improved rates of gas transport while preserving good selectivity. These membranes can be further transformed by an acid doping process after fabrication to achieve excellent permeation rates and high selectivities for particular gas separations. Prior to the use of concentrated EB solutions, the formation of integrally skinned asymmetric membranes was not possible, since films and fibers made from <5% w/w polyaniline solutions were found to disintegrate during the IP process.
Survivability Enhanced Run-Flat Variable Footprint Tires
2010-08-17
with tire tread . By varying the thickness and geometry of the polyurethane soft layer, this unique tire -wheel assembly can generate a wide array of...carcass severely damaged/punctured, provide the same dynamic deflection as the normal pneumatic tire , and provide similar tread life. Could a tire be...be for an optimized shape. Fig 8 shows the actual process applied to a current tire . The carbon fiber was added by removing the tread , cutting
Dynamics-based Nondestructive Structural Monitoring Techniques
2012-06-21
made from AS4/8552-2 carbon epoxy prepregs . The layup sequence: was [(0/45/90/-45)S]2 as illustrated in Figure 3.37. Each layer had the thickness of...using facilities available at Penn State. Hexcel AS4/8552 unidirectional carbon/epoxy prepregs were used in the fabrication as raw materials. The... prepregs were cut in pieces with different fiber orientations and 132 stacked together following different stacking sequences. The stacked prepregs
Dada, Tanuj; Aggarwal, A; Bali, S J; Sharma, A; Shah, B M; Angmo, D; Panda, A
2013-01-01
Myopia presents a significant challenge to the ophthalmologist as myopic discs are often large, tilted, with deep cups and have a thinner neuroretinal rim all of which may mimic glaucomatous optic nerve head changes causing an error in diagnosis. To evaluate the retinal fiber layer (RNFL) thickness in low, moderate and high myopia using scanning laser polarimetry with variable corneal compensation (GDxVCC). One hundred eyes of 100 emmetropes, 30 eyes of low myopes (0 to - 4 D spherical equivalent(SE), 45 eyes with moderate myopia (- 4 to - 8D SE), and 30 eyes with high myopia (- 8 to - 15D SE) were subjected to retinal nerve fiber layer assessment using the scanning laser polarimetry (GDxVCC) in all subjects using the standard protocol. Subjects with IOP > 21 mm Hg, optic nerve head or visual field changes suggestive of glaucoma were excluded from the study. The major outcome parameters were temporal-superior-nasal-inferiortemporal (TSNIT) average, the superior and inferior average and the nerve fibre indicator (NFI). The TSNIT average (p = 0.009), superior (p = 0.001) and inferior average (p = 0.008) were significantly lower; the NFI was higher (P less than 0.001) in moderate myopes as compared to that in emmetropes. In high myopia the RNFL showed supranormal values; the TSNIT average, superior and inferior average was significantly higher(p less than 0.001) as compared to that in emmetropes. The RNFL measurements on scanning laser polarimetry are affected by the myopic refractive error. Moderate myopes show a significant thinning of the RNFL. In high myopia due to peripapillary chorioretinal atrophy and contribution of scleral birefringence, the RNFL values are abnormally high. These findings need to be taken into account while assessing and monitoring glaucoma damage in moderate to high myopes on GDxVCC. © NEPjOPH.
Plasmon-organic fiber interactions in diamond-like carbon coated nanostructured gold films
NASA Astrophysics Data System (ADS)
Cielecki, Paweł Piotr; Sobolewska, Elżbieta Karolina; Kostiuočenko, Oksana; Leißner, Till; Tamulevičius, Tomas; Tamulevičius, Sigitas; Rubahn, Horst-Günter; Adam, Jost; Fiutowski, Jacek
2017-11-01
Gold is the most commonly used plasmonic material, however soft and prone to mechanical deformations. It has been shown that the durability of gold plasmonic substrates can be improved by applying a protective diamond-like carbon (DLC) coating. In this work, we investigate the influence of such protective layers on plasmonic interactions in organic-plasmonic hybrid systems. We consider systems, consisting of 1-Cyano-quaterphenylene nanofibers on top of gold nano-square plasmonic arrays, coated with protective layers of varying thickness. We numerically investigate the spectral position of surface plasmon polariton resonances and electric field intensity, as a function of protective layer thickness, using the finite-difference time-domain method. To confirm the numerically indicated field enhancement preservation on top of protective layers, we experimentally map the second harmonic response of organic nanofibers. Subsequently, we characterize the plasmonic coupling between organic nanofibers and underlying substrates, considered as one of the main loss channels for photoluminescence from nanofibers, by time-resolved photoluminescence spectroscopy. Our findings reveal that, for the investigated system, plasmonic interactions are preserved for DLC coatings up to 55 nm. This is relevant for the fabrication of new passive and active plasmonic components with increased durability and hence prolonged lifetime.
Surface plasmon resonance based fiber optic pH sensor utilizing Ag/ITO/Al/hydrogel layers.
Mishra, Satyendra K; Gupta, Banshi D
2013-05-07
The fabrication and characterization of a surface plasmon resonance based pH sensor using coatings of silver, ITO (In2O3:SnO2), aluminium and smart hydrogel layers over an unclad core of an optical fiber have been reported. The silver, aluminium and ITO layers were coated using a thermal evaporation technique, while the hydrogel layer was prepared using a dip-coating method. The sensor works on the principle of detecting changes in the refractive index of the hydrogel layer due to its swelling and shrinkage caused by changes in the pH of the fluid surrounding the hydrogel layer. The sensor utilizes a wavelength interrogation technique and operates in a particular window of low and high pH values. Increasing the pH value of the fluid causes swelling of the hydrogel layer, which decreases its refractive index and results in a shift of the resonance wavelength towards blue in the transmitted spectra. The thicknesses of the ITO and aluminium layers have been optimized to achieve the best performance of the sensor. The ITO layer increases the sensitivity while the aluminium layer increases the detection accuracy of the sensor. The proposed sensor possesses maximum sensitivity in comparison to the sensors reported in the literature. A negligible effect of ambient temperature in the range 25 °C to 45 °C on the performance of the sensor has been observed. The additional advantages of the sensor are short response time, low cost, probe miniaturization, probe re-usability and the capability of remote sensing.
NASA Astrophysics Data System (ADS)
Viator, John A.; Paltauf, Guenther; Jacques, Steven L.; Prahl, Scott A.
2001-06-01
An endoscopic photoacoustic probe is designed and tested for use in PDT treatment of esophageal cancer. The probe, measuring less than 2.5 mm in diameter, was designed to fit within the lumen of an endoscope that will be inserted into an esophagus after PDT. PDT treatment results in a blanched, necrotic layer of cancerous tissue over a healthy, deeper layer of perfused tissue. The photoacoustic probe was designed to use acoustic propagation time to determine the thickness of the blanched surface of the esophagus, which corresponds to treatment depth. A side-firing 600 micrometers fiber delivered 532 nm laser light to induce acoustic waves in the perfused layer of the esophagus beneath the blanched (treated) layer. A PVDF transducer detected the induced acoustic waves and transmitted the signal to an oscilloscope. The probe was tested on clear and turbid tissue phantom layers over an optically absorbing dye solution.
NASA Astrophysics Data System (ADS)
Schelkanova, Irina; Pandya, Aditya; Saiko, Guennadi; Nacy, Lidia; Babar, Hannan; Shah, Duoaud; Lilge, Lothar; Douplik, Alexandre
2016-01-01
A portable, spatially resolved, diffuse reflectance lensless imaging technique based on the charge-coupled device or complementary metal-oxide semiconductor sensor directly coupled to the fiber optic bundle is proposed for visualization of subsurface structures such as superficial microvasculature in the epithelium. We discuss an experimental method for emulating a lensless imaging setup via raster scanning a single fiber-optic cable over a microfluidic phantom containing periodic hemoglobin absorption contrast. To evaluate the ability of the technique to recover information about the subsurface linear structures, scattering layers formed of the Sylgard® 184 Silicone Elastomer and titanium dioxide were placed atop the microfluidic phantom. Thickness of the layers ranged from 0.2 to 0.7 mm, and the values of the reduced scattering coefficient (μs‧) were between 0.85 and 4.25 mm-1. The results demonstrate that fiber-optic, lensless platform can be used for two-dimensional imaging of absorbing inclusions in diffuse reflectance mode. In these experiments, it was shown that diffuse reflectance imaging can provide sufficient spatial sampling of the phantom for differentiation of 30 μm structural features of the embedded absorbing pattern inside the scattering media.
Fiber optic pH sensor with self-assembled polymer multilayer nanocoatings.
Shao, Li-Yang; Yin, Ming-Jie; Tam, Hwa-Yaw; Albert, Jacques
2013-01-24
A fiber-optic pH sensor based on a tilted fiber Bragg grating (TFBG) with electrostatic self-assembly multilayer sensing film is presented. The pH sensitive polymeric film, poly(diallyldimethylammonium chloride) (PDDA) and poly(acrylic acid) (PAA) was deposited on the circumference of the TFBG with the layer-by-layer (LbL) electrostatic self-assembly technique. The PDDA/PAA film exhibits a reduction in refractive index by swelling in different pH solutions. This effect results in wavelength shifts and transmission changes in the spectrum of the TFBG. The peak amplitude of the dominant spectral fringes over a certain window of the transmission spectrum, obtained by FFT analysis, has a near-linear pH sensitivity of 117 arbitrary unit (a.u.)/pH unit and an accuracy of ±1 a.u. (in the range of pH 4.66 to pH 6.02). The thickness and surface morphology of the sensing multilayer film were characterized to investigate their effects on the sensor's performance. The dynamic response of the sensor also has been studied (10 s rise time and 18 s fall time for a sensor with six bilayers of PDDA/PAA).
Tunable engineered skin mechanics via coaxial electrospun fiber core diameter.
Blackstone, Britani Nicole; Drexler, Jason William; Powell, Heather Megan
2014-10-01
Autologous engineered skin (ES) offers promise as a treatment for massive full thickness burns. Unfortunately, ES is orders of magnitude weaker than normal human skin causing it to be difficult to apply surgically and subject to damage by mechanical shear in the early phases of engraftment. In addition, no manufacturing strategy has been developed to tune ES biomechanics to approximate the native biomechanics at different anatomic locations. To enhance and tune ES biomechanics, a coaxial (CoA) electrospun scaffold platform was developed from polycaprolactone (PCL, core) and gelatin (shell). The ability of the coaxial fiber core diameter to control both scaffold and tissue mechanics was investigated along with the ability of the gelatin shell to facilitate cell adhesion and skin development compared to pure gelatin, pure PCL, and a gelatin-PCL blended fiber scaffold. CoA ES exhibited increased cellular adhesion and metabolism versus PCL alone or gelatin-PCL blend and promoted the development of well stratified skin with a dense dermal layer and a differentiated epidermal layer. Biomechanics of the scaffold and ES scaled linearly with core diameter suggesting that this scaffold platform could be utilized to tailor ES mechanics for their intended grafting site and reduce graft damage in vitro and in vivo.
Esquivel, K; Arriaga, L G; Rodríguez, F J; Martínez, L; Godínez, Luis A
2009-08-01
Electrochemical advanced oxidation processes (EAOPs) are used to chemically burn non biodegradable complex organic compounds that are present in polluted effluents. A common approach involves the use of TiO2 semiconductor substrates as either photocatalytic or photoelectrocatalytic materials in reactors that produce a powerful oxidant (hydroxyl radical) that reacts with pollutant species. In this context, the purpose of this work is to develop a new TiO2 based photoanode using an optic fiber support. The novel arrangement of a TiO2 layer positioned on top of a surface modified optical fiber substrate, allowed the construction of a photoelectrochemical reactor that works on the basis of an internally illuminated approach. In this way, a semi-conductive optical fiber modified surface was prepared using 30 microm thickness SnO2:Sb films on which the photoactive TiO2 layer was electrophoretically deposited. UV light transmission experiments were conducted to evaluate the transmittance along the optical fiber covered with SnO2:Sb and TiO2 showing that 43% of UV light reached the optical fiber tip. With different illumination configurations (external or internal), it was possible to get an increase in the amount of photo-generated H(2)O(2) close to 50% as compared to different types of TiO2 films. Finally, the electro-Fenton photoelectrocatalytic Oxidation process studied in this work was able to achieve total color removal of Azo orange II dye (15 mg L(-1)) and a 57% removal of total organic carbon (TOC) within 60 min of degradation time.
Irving, Thomas; Wu, Yiming; Bekyarova, Tanya; Farman, Gerrie P.; Fukuda, Norio; Granzier, Henk
2011-01-01
We studied the effect of titin-based passive tension on sarcomere structure by simultaneously measuring passive tension and low-angle x-ray diffraction patterns on passive fiber bundles from rabbit skinned psoas muscle. We used a stretch-hold-release protocol with measurement of x-ray diffraction patterns at various passive tension levels during the hold phase before and after passive stress relaxation. Measurements were performed in relaxing solution without and with dextran T-500 to compress the lattice toward physiological levels. The myofilament lattice spacing was measured in the A-band (d1,0) and Z-disk (dZ) regions of the sarcomere. The axial spacing of the thick-filament backbone was determined from the sixth myosin meridional reflection (M6) and the equilibrium positions of myosin heads from the fourth myosin layer line peak position and the I1,1/I1,0 intensity ratio. Total passive tension was measured during the x-ray experiments, and a differential extraction technique was used to determine the relations between collagen- and titin-based passive tension and sarcomere length. Within the employed range of sarcomere lengths (∼2.2–3.4 μm), titin accounted for >80% of passive tension. X-ray results indicate that titin compresses both the A-band and Z-disk lattice spacing with viscoelastic behavior when fibers are swollen after skinning, and elastic behavior when the lattice is reduced with dextran. Titin also increases the axial thick-filament spacing, M6, in an elastic manner in both the presence and absence of dextran. No changes were detected in either I1,1/I1,0 or the position of peaks on the fourth myosin layer line during passive stress relaxation. Passive tension and M6 measurements were converted to thick-filament compliance, yielding a value of ∼85 m/N, which is several-fold larger than the thick-filament compliance determined by others during the tetanic tension plateau of activated intact muscle. This difference can be explained by the fact that thick filaments are more compliant at low tension (passive muscle) than at high tension (tetanic tension). The implications of our findings are discussed. PMID:21402032
Development of orthotropic birefringent materials for photoelastic stress analysis
NASA Technical Reports Server (NTRS)
Daniel, I. M.; Niiro, T.; Koller, G. M.
1981-01-01
Materials were selected and fabrication procedures developed for orthotropic birefringent materials. An epoxy resin (Maraset 658/558 system) was selected as the matrix material. Fibers obtained from style 3733 glass cloth and type 1062 glass roving were used as reinforcement. Two different fabrication procedures were used. In the first one, layers of unidirectional fibers removed from the glass cloth were stacked, impregnated with resin, bagged and cured in the autoclave at an elevated temperature. In the second procedure, the glass roving was drywound over metal frames, impregnated with resin and cured at room temperature under pressure and vacuum in an autoclave. Unidirectional, angle-ply and quasi-isotropic laminates of two thicknesses and with embedded flaws were fabricated. The matrix and the unidirectional glass/epoxy material were fully characterized. The density, fiber volume ratio, mechanical, and optical properties were determined. The fiber volume ratio was over 0.50. Birefringent properties were in good agreement with predictions based on a stress proportioning concept and also, with one exception, with properties predicted by a finite element analysis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anggoro, Didi Dwi, E-mail: anggorophd@gmail.com; Kristiana, Nunung, E-mail: nuna.c631@gmail.com
Ballistic protection equipment, such as a bulletproof vest, is a soldier’s most important means of preserving life and survivability in extreme combat conditions. The bulletproof vests are designed to protect the user’s chest from injury without disturbing the ability to perform his duties. Aromatic polyamide or aramid fibers known under the trade name Kevlar, Trawon and so is synthetic fiber materials commonly used in the manufacture of bulletproof vests. This synthetic fibers have high tensile strength and ductility. Kevlar is expensive and imported material. In this study, will introduce local natural raw materials, ramie fiber (Boehmeria nivea) which is cheapermore » and environmentally friendly. It has enough tenacity and tensile strength as a bulletproof vest. This experiment uses two panels, there are Panel A as front surface of Panel B. Panel A is a combination of ramie and epoxide matrix, while panel B is only ramie. From several variations of experimental combinations between Panel A and Panel B, optimal combination obtained with 16 layers of panel A and 31-34 layers of panel B which is able to protect againts cal. 7.65 mm × 17 mm (.32 ACP) bullet fired through pistol .32 Pindad from a distance of 20 meters. Panel with a size of 20 cm × 20 cm has a total thickness between 12,922 to13,745 mm and a total weight between 506,26 to 520,926gram. Scanning electron microscopy (SEM) observations indicated that the porosity and surface area of the ramie fiber is smooth, fiber surfaces showed topography with micropores. SEM also showed well-arranged structure of fibers bonding. Energy Dispersive X-ray (EDX) analysis indicated 100 % carbon contents in ramie fiber. Test result indicates that panel from composite ramie-epoxide can reach the level 1of International Standard of NIJ - 010104. Compared to panel from polyester fiber, the panel from composite ramie-epoxide (0,50-0,52 kg) is lighter weight than panel polyester fiber (1,642 kg)« less
Basic analytical investigation of plasma-chemically modified carbon fibers1
NASA Astrophysics Data System (ADS)
Bubert, H.; Ai, X.; Haiber, S.; Heintze, M.; Brüser, V.; Pasch, E.; Brandl, W.; Marginean, G.
2002-10-01
The background of the present investigation is to enhance the overall adherence of vapor grown carbon fibers (VGCF) to the surrounding polymer matrix in different applications by forming polar groups at their surfaces and by modifying the surface morphology. This has been done by plasma treatments using a low-pressure plasma with different gases, flow rates, pressures and powers. Two different types of carbon fibers were investigated: carbon microfibers and carbon nanofibers. The characterization of fiber surfaces was achieved by photoelectron spectroscopy (XPS), contact angle measurements and titration. These investigations were accompanied by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The oxygen plasma treatment of the fibers changes the surfaces by forming a layer with a thickness of the order of one nanometer mainly consisting of functional groups like hydroxyl, carbonyl and carboxyl. After functionalization of the complete surface, a further plasma treatment does not enhance the superficial oxygen content but changes slightly the portions of the functional groups. A comparison of the methods applied provides a largely consistent image of the effect of plasma treatment.
Multicenter reliability of semiautomatic retinal layer segmentation using OCT
Oberwahrenbrock, Timm; Traber, Ghislaine L.; Lukas, Sebastian; Gabilondo, Iñigo; Nolan, Rachel; Songster, Christopher; Balk, Lisanne; Petzold, Axel; Paul, Friedemann; Villoslada, Pablo; Brandt, Alexander U.; Green, Ari J.
2018-01-01
Objective To evaluate the inter-rater reliability of semiautomated segmentation of spectral domain optical coherence tomography (OCT) macular volume scans. Methods Macular OCT volume scans of left eyes from 17 subjects (8 patients with MS and 9 healthy controls) were automatically segmented by Heidelberg Eye Explorer (v1.9.3.0) beta-software (Spectralis Viewing Module v6.0.0.7), followed by manual correction by 5 experienced operators from 5 different academic centers. The mean thicknesses within a 6-mm area around the fovea were computed for the retinal nerve fiber layer, ganglion cell layer (GCL), inner plexiform layer (IPL), inner nuclear layer, outer plexiform layer (OPL), and outer nuclear layer (ONL). Intraclass correlation coefficients (ICCs) were calculated for mean layer thickness values. Spatial distribution of ICC values for the segmented volume scans was investigated using heat maps. Results Agreement between raters was good (ICC > 0.84) for all retinal layers, particularly inner retinal layers showed excellent agreement across raters (ICC > 0.96). Spatial distribution of ICC showed highest values in the perimacular area, whereas the ICCs were poorer for the foveola and the more peripheral macular area. The automated segmentation of the OPL and ONL required the most correction and showed the least agreement, whereas differences were less prominent for the remaining layers. Conclusions Automated segmentation with manual correction of macular OCT scans is highly reliable when performed by experienced raters and can thus be applied in multicenter settings. Reliability can be improved by restricting analysis to the perimacular area and compound segmentation of GCL and IPL. PMID:29552598
Aligned Layers of Silver Nano-Fibers.
Golovin, Andrii B; Stromer, Jeremy; Kreminska, Liubov
2012-02-01
We describe a new dichroic polarizers made by ordering silver nano-fibers to aligned layers. The aligned layers consist of nano-fibers and self-assembled molecular aggregates of lyotropic liquid crystals. Unidirectional alignment of the layers is achieved by means of mechanical shearing. Aligned layers of silver nano-fibers are partially transparent to a linearly polarized electromagnetic radiation. The unidirectional alignment and density of the silver nano-fibers determine degree of polarization of transmitted light. The aligned layers of silver nano-fibers might be used in optics, microwave applications, and organic electronics.
Sehi, Mitra; Greenfield, David S.
2006-01-01
Purpose To describe a case of progressive glaucomatous optic neuropathy using scanning laser polarimetry with fixed (SLP-FCC) and variable corneal compensation (SLP-VCC) and optical coherence tomography (OCT). Design Observational case report. Methods A 21-year-old male with juvenile primary open-angle glaucoma developed progression because of noncompliance with therapy. The patient underwent dilated stereoscopic examination and photography of the optic disk, standard automated perimetry (SAP), OCT, and SLP imaging with FCC and VCC at the baseline examination and after four years of follow-up. Results Optic disk, retinal nerve fiber layer (RNFL) atrophy, and SAP progression was observed. Reduction in mean RNFL thickness (average, superior, inferior) was 18, 18, and 27 microns (OCT); 22, 40, and 17 microns (SLP-FCC); and 6, 12, and 12 microns (SLP-VCC), respectively. Conclusions This case demonstrates that digital imaging of the peripapillary RNFL is capable of documentation and measurement of progressive glaucomatous RNFL atrophy. PMID:17157591
Erosion and Modifications of Tungsten-Coated Carbon and Copper Under High Heat Flux
NASA Astrophysics Data System (ADS)
Liu, Xiang; S, Tamura; K, Tokunaga; N, Yoshida; Zhang, Fu; Xu, Zeng-yu; Ge, Chang-chun; N, Noda
2003-08-01
Tungsten-coated carbon and copper was prepared by vacuum plasma spraying (VPS) and inert gas plasma spraying (IPS), respectively. W/CFC (Tungsten/Carbon Fiber-Enhanced material) coating has a diffusion barrier that consists of W and Re multi-layers pre-deposited by physical vapor deposition on carbon fiber-enhanced materials, while W/Cu coating has a graded transition interface. Different grain growth processes of tungsten coatings under stable and transient heat loads were observed, their experimental results indicated that the recrystallizing temperature of VPS-W coating was about 1400 °C and a recrystallized columnar layer of about 30 μm thickness was formed by cyclic heat loads of 4 ms pulse duration. Erosion and modifications of W/CFC and W/Cu coatings under high heat load, such as microstructure changes of interface, surface plastic deformations and cracks, were investigated, and the erosion mechanism (erosion products) of these two kinds of tungsten coatings under high heat flux was also studied.
Cone dysfunctions in retinitis pigmentosa with retinal nerve fiber layer thickening
Sobacı, Güngör; Özge, Gökhan; Gündoğan, Fatih Ç
2012-01-01
Purpose To investigate whether or not thicker retinal nerve fiber layer (RNFL) in retinitis pigmentosa (RP) patients relates to functional abnormalities of the photoreceptors. Methods Optical coherence tomography-based RNFL thickness was measured by Stratus-3™ (Zeiss, Basel, Switzerland) optical coherence tomography and electroretinogram (ERG) recordings made using the RETI-port® system (Roland, Wiesbaden, Germany) in 27 patients with retinitis pigmentosa and in 30 healthy subjects. Results Photopic ERG b-wave amplitude, cone ERG b-wave latency, 30 Hz flicker amplitude, and 30 Hz flicker latency had significant correlations to the RNFL-temporal (r = −0.55, P = 0.004, r = 0.68, P = 0.001, r = −0.65, P = 0.001, and r = −0.52, P = 0.007, respectively). Eyes with thicker RNFL (ten eyes) differed significantly from those with thinner RNFL (eight eyes) regarding cone ERG b-wave latency values only (P = 0.001). Conclusion Thicker RNFL in patients with retinitis pigmentosa may be associated with functional abnormality of the cone system. PMID:22536039
Cone dysfunctions in retinitis pigmentosa with retinal nerve fiber layer thickening.
Sobacı, Güngör; Ozge, Gökhan; Gündoğan, Fatih Ç
2012-01-01
To investigate whether or not thicker retinal nerve fiber layer (RNFL) in retinitis pigmentosa (RP) patients relates to functional abnormalities of the photoreceptors. Optical coherence tomography-based RNFL thickness was measured by Stratus-3™ (Zeiss, Basel, Switzerland) optical coherence tomography and electroretinogram (ERG) recordings made using the RETI-port(®) system (Roland, Wiesbaden, Germany) in 27 patients with retinitis pigmentosa and in 30 healthy subjects. Photopic ERG b-wave amplitude, cone ERG b-wave latency, 30 Hz flicker amplitude, and 30 Hz flicker latency had significant correlations to the RNFL-temporal (r = -0.55, P = 0.004, r = 0.68, P = 0.001, r = -0.65, P = 0.001, and r = -0.52, P = 0.007, respectively). Eyes with thicker RNFL (ten eyes) differed significantly from those with thinner RNFL (eight eyes) regarding cone ERG b-wave latency values only (P = 0.001). Thicker RNFL in patients with retinitis pigmentosa may be associated with functional abnormality of the cone system.
Transition-metal dichalcogenides heterostructure saturable absorbers for ultrafast photonics.
Chen, Hao; Yin, Jinde; Yang, Jingwei; Zhang, Xuejun; Liu, Mengli; Jiang, Zike; Wang, Jinzhang; Sun, Zhipei; Guo, Tuan; Liu, Wenjun; Yan, Peiguang
2017-11-01
In this Letter, high-quality WS 2 film and MoS 2 film were vertically stacked on the tip of a single-mode fiber in turns to form heterostructure (WS 2 -MoS 2 -WS 2 )-based saturable absorbers with all-fiber integrated features. Their nonlinear saturable absorption properties were remarkable, such as a large modulation depth (∼16.99%) and a small saturable intensity (6.23 MW·cm -2 ). Stable pulses at 1.55 μm with duration as short as 296 fs and average power as high as 25 mW were obtained in an erbium-doped fiber laser system. The results demonstrate that the proposed heterostructures own remarkable nonlinear optical properties and offer a platform for adjusting nonlinear optical properties by stacking different transition-metal dichalcogenides or modifying the thickness of each layer, paving the way for engineering functional ultrafast photonics devices with desirable properties.
Optical fiber plasmonic lens for near-field focusing fabricated through focused ion beam
NASA Astrophysics Data System (ADS)
Sloyan, Karen; Melkonyan, Henrik; Moreira, Paulo; Dahlem, Marcus S.
2017-02-01
We report on numerical simulations and fabrication of an optical fiber plasmonic lens for near-field focusing applications. The plasmonic lens consists of an Archimedean spiral structure etched through a 100 nm-thick Au layer on the tip of a single-mode SM600 optical fiber operating at a wavelength of 632:8 nm. Three-dimensional finite-difference time-domain computations show that the relative electric field intensity of the focused spot increases 2:1 times when the number of turns increases from 2 to 12. Furthermore, a reduction of the intensity is observed when the initial inner radius is increased. The optimized plasmonic lens focuses light into a spot with a full-width at half-maximum of 182 nm, beyond the diffraction limit. The lens was fabricated by focused ion beam milling, with a 200nm slit width.
Ding, Zicheng; Chen, Bo; Ding, Junqiao; Wang, Lixiang; Han, Yanchun
2014-07-01
Supramolecular metallogels can be gained from the phosphonate substituted 4,4'-bis(N-carbazolyl)biphenyl (PCBP) in the presence of aluminum chloride in alcohols, which can donate oxygen to aid proton transfer in the aluminum organophosphorus complexes. Inside the metallogels, three-dimensional fiber networks with nanofibers entangling and intersecting with each other inside are formed. The nanofibers show layered structures with a period thickness of 0.82 nm. As the content of aluminum(III) increases, the size of the fibers becomes smaller and the fibers pack more densely. It makes the transparent gel become turbid but nevertheless improves the stability of the metallogels. NMR, FT-IR and fluorescence spectroscopy show that the coordination interactions between the phosphonate groups of PCBP molecules and aluminum(III) ions as well as the π-π interactions among PCBP molecules are involved during the gel formation process. Copyright © 2014 Elsevier Inc. All rights reserved.
A magnetostrictive composite-fiber Bragg Grating sensor.
Quintero, Sully M M; Braga, Arthur M B; Weber, Hans I; Bruno, Antonio C; Araújo, Jefferson F D F
2010-01-01
This paper presents a light and compact optical fiber Bragg Grating sensor for DC and AC magnetic field measurements. The fiber is coated by a thick layer of a magnetostrictive composite consisting of particles of Terfenol-D dispersed in a polymeric matrix. Among the different compositions for the coating that were tested, the best magnetostrictive response was obtained using an epoxy resin as binder and a 30% volume fraction of Terfenol-D particles with sizes ranging from 212 to 300 μm. The effect of a compressive preload in the sensor was also investigated. The achieved resolution was 0.4 mT without a preload or 0.3 mT with a compressive pre-stress of 8.6 MPa. The sensor was tested at magnetic fields of up to 750 mT under static conditions. Dynamic measurements were conducted with a magnetic unbalanced four-pole rotor.
A Magnetostrictive Composite-Fiber Bragg Grating Sensor
Quintero, Sully M. M.; Braga, Arthur M. B.; Weber, Hans I.; Bruno, Antonio C.; Araújo, Jefferson F. D. F.
2010-01-01
This paper presents a light and compact optical fiber Bragg Grating sensor for DC and AC magnetic field measurements. The fiber is coated by a thick layer of a magnetostrictive composite consisting of particles of Terfenol-D dispersed in a polymeric matrix. Among the different compositions for the coating that were tested, the best magnetostrictive response was obtained using an epoxy resin as binder and a 30% volume fraction of Terfenol-D particles with sizes ranging from 212 to 300 μm. The effect of a compressive preload in the sensor was also investigated. The achieved resolution was 0.4 mT without a preload or 0.3 mT with a compressive pre-stress of 8.6 MPa. The sensor was tested at magnetic fields of up to 750 mT under static conditions. Dynamic measurements were conducted with a magnetic unbalanced four-pole rotor. PMID:22163644
Wei, Pein-Chi; Laurell, Lars; Lingen, Mark W; Geivelis, Milton
2002-03-01
In part 1 of this study, we compared the clinical efficacy of freeze-dried acellular dermal matrix (ADM) allograft in 6 patients with autogenous free gingival graft (FGG) in 6 patients for increasing the width of attached gingiva in the mandibular anterior area. The purpose of the present study was to histologically compare the microstructure of ADM and FGG treated sites from the same group. Biopsies were harvested from all 12 patients at 6 months postsurgery. The biopsies included the grafted sites with adjacent alveolar mucosa and gingiva propria and also donor palatal mucosa saved at the time of surgery. The 5 microm thick, neutral buffered formalin fixed, paraffin-embedded tissue sections were stained with hematoxylin and eosin (H&E), Masson's trichrome, and Verhoeff-van Gieson stains in order to investigate the density of collagen and elastic fibers. Additional sections were stained with periodic acid-Schiff (PAS) and Papanicolaou's stain to identify the presence of glycogen granules in the epithelial layer and to highlight the keratin layer respectively. The unique appearance of ADM-derived tissue did not parallel any known oral mucosa. The connective tissue portion contained dense to extremely dense collagen fibers along with scattered elastic fibers. The demarcations between the ADM graft and the coronal gingiva as well as the apical alveolar mucosa were usually not very defined. A moderate to thin epithelial layer, with heterogeneous expression of keratinization and flat epithelium-connective tissue interface, covered the lamina propria. Both the thickness of the epithelium and the degree of keratinization decreased in apical direction, being mostly para- or orthokeratinized in the area close to gingiva and non-keratinized adjacent to the alveolar mucosa. In the FGG-treated sites, the density of collagen fibers was less than in ADM-derived tissue, palatal mucosa, and gingiva. Elastic fibers were very sparse, comparable to gingiva, but much less than in ADM-derived tissue. The epithelium was moderate, somewhat thinner but the shape of the rete ridges resembled that of palatal mucosa. Similar to gingiva epithelium, the epithelium of the FGG-treated area was relatively uniform in both thickness and keratinization, mostly para-keratinized with a well defined border to the non-keratinized alveolar mucosa. Underneath the FGG-alveolar mucosa junction, a scar band composed of extremely dense collagen fibers consistently existed. The results of this 6-month histological evaluation suggest that: 1) the resultant tissue types of ADM grafts were similar to "scar" tissue; 2) the non-vital dermal matrix of ADM allograft lacked the capability of directing cyto-differentiation of the covering epithelium; 3) autogenous FGG-derived tissue was neither identical to donor palatal mucosa nor to adjacent gingiva propria; 4) the connective tissue of donor palatal mucosa only partially contributed to the differentiation of the epithelium covering the FGG-treated area; and 5) the epithelium/connective tissue microenvironment surrounding the recipient site influenced the epithelial differentiation of the graft; this may play a more critical role in ADM grafting than in the grafting of autogenous FGG.
Surface plasmon-assisted microscope.
Borejdo, Julian; Gryczynski, Zygmunt; Fudala, Rafal; Joshi, Chaitanya R; Borgmann, Kathleen; Ghorpade, Anuja; Gryczynski, Ignacy
2018-06-01
Total internal reflection microscopy (TIRF) has been a powerful tool in biological research. The most valuable feature of the method has been the ability to image 100- to 200-nm-thick layer of cell features adjacent to a coverslip, such as membrane lipids, membrane receptors, and structures proximal-to-basal membranes. Here, we demonstrate an alternative method of imaging thin-layer proximal-to-basal membranes by placing a sample on a high refractive index coverslip covered by a thin layer of gold. The sample is illuminated using the Kretschmann method (i.e., from the top to an aqueous medium). Fluorophores that are close to the metal surface induce surface plasmons in the metal film. Fluorescence from fluorophores near the metal surface couple with surface plasmons allowing them to penetrate the metal surface and emerge at a surface plasmon coupled emission angle. The thickness of the detection layer is further reduced in comparison with TIRF by metal quenching of fluorophores at a close proximity (below 10 nm) to a surface. Fluorescence is collected by a high NA objective and imaged by EMCCD or converted to a signal by avalanche photodiode fed by a single-mode optical fiber inserted in the conjugate image plane of the objective. The system avoids complications of through-the-objective TIRF associated with shared excitation and emission light path, has thin collection thickness, produces excellent background rejection, and is an effective method to study molecular motion. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).
NASA Astrophysics Data System (ADS)
Peng, Chunqing; Thio, Yonathan; Gerhardt, Rosario
2009-03-01
Conductive paper has been fabricated by layer-by-layer (LBL) assembly of polyelectrolytes and indium tin oxide (ITO) nanoparticles onto wood fibers, followed by traditional paper making method. The wood fibers were first coated with polyethyleneimine (PEI) and then LBL assembled with poly(sodium 4-styrenesulfonate) (PSS) and ITO for several bilayers. The AC electrical properties, measured for frequencies ranging from 0.01 Hz to 1 MHz, will be reported for the in-plane (IP) and through-the-thickness (TT) directions. With 10 bilayers of PSS/ITO assembly on wood fibers, the conductivity of as-prepared paper was improved by more than six orders of magnitude and reach to 5.2x10-6 S cm-1 in IP direction and 1.9x10-8 S cm-1 in TT direction. The percolation phenomenon of ITO nanoparticles through the handsheet in both directions was observed through current atomic force microscopy (I-AFM). By applying a bias voltage, either on one end of the paper stripes or on one side of the paper handsheet, the current can be detected on the other end of the paper stripes or on the other side of the paper handsheet. PEI can be used to modify the ITO suspension and significantly improve the LBL procedure. The mechanism of PEI modifying ITO colloidal suspension will be discussed.
Priority design parameters of industrialized optical fiber sensors in civil engineering
NASA Astrophysics Data System (ADS)
Wang, Huaping; Jiang, Lizhong; Xiang, Ping
2018-03-01
Considering the mechanical effects and the different paths for transferring deformation, optical fiber sensors commonly used in civil engineering have been systematically classified. Based on the strain transfer theory, the relationship between the strain transfer coefficient and allowable testing error is established. The proposed relationship is regarded as the optimal control equation to obtain the optimal value of sensors that satisfy the requirement of measurement precision. Furthermore, specific optimization design methods and priority design parameters of the classified sensors are presented. This research indicates that (1) strain transfer theory-based optimization design method is much suitable for the sensor that depends on the interfacial shear stress to transfer the deformation; (2) the priority design parameters are bonded (sensing) length, interfacial bonded strength, elastic modulus and radius of protective layer and thickness of adhesive layer; (3) the optimization design of sensors with two anchor pieces at two ends is independent of strain transfer theory as the strain transfer coefficient can be conveniently calibrated by test, and this kind of sensors has no obvious priority design parameters. Improved calibration test is put forward to enhance the accuracy of the calibration coefficient of end-expanding sensors. By considering the practical state of sensors and the testing accuracy, comprehensive and systematic analyses on optical fiber sensors are provided from the perspective of mechanical actions, which could scientifically instruct the application design and calibration test of industrialized optical fiber sensors.
Rhee, Sunki; Kitamura, Kei; Masaaki, Kasahara; Katori, Yukio; Murakami, Gen; Abe, Shin-ichi
2016-01-01
Macrophages play an important role in aging-related muscle atrophy (i.e., sarcopenia). We examined macrophage density in six striated muscles (cricopharyngeus muscle, posterior cricoarytenoideus muscle, genioglossus muscle, masseter muscle, infraspinatus muscle, and external anal sphincter). We examined 14 donated male cadavers and utilized CD68 immunohistochemistry to clarify macrophage density in muscles. The numbers of macrophages per striated muscle fiber in the larynx and pharynx (0.34 and 0.31) were 5–6 times greater than those in the tongue, shoulder, and anus (0.05–0.07) with high statistical significance. Thick muscle fibers over 80 µm in diameter were seen in the pharynx, larynx, and anal sphincter of two limited specimens. Conversely, in the other sites or specimens, muscle fibers were thinner than 50 µm. We did not find any multinuclear muscle cells suggestive of regeneration. At the beginning of the study, we suspected that mucosal macrophages might have invaded into the muscle layer of the larynx and pharynx, but we found no evidence of inflammation in the mucosa. Likewise, the internal anal sphincter (a smooth muscle layer near the mucosa) usually contained fewer macrophages than the external sphincter. The present result suggest that, in elderly men, thinning and death of striated muscle fibers occur more frequently in the larynx and pharynx than in other parts of the body. PMID:27722010
Jeong, Jae Hoon; Choi, Yun Jeong; Park, Ki Ho; Kim, Dong Myung
2016-01-01
Purpose To evaluate the effect of multiple covariates on the diagnostic performance of the Cirrus high-definition optical coherence tomography (HD-OCT) for glaucoma detection. Methods A prospective case-control study was performed and included 173 recently diagnosed glaucoma patients and 63 unaffected individuals from the Macular Ganglion Cell Imaging Study. Regression analysis of receiver operating characteristic were conducted to evaluate the influence of age, spherical equivalent, axial length, optic disc size, and visual field index on the macular ganglion cell-inner plexiform layer (GCIPL) and peripapillary retinal nerve fiber layer (RNFL) measurements. Results Disease severity, as measured by visual field index, had a significant effect on the diagnostic performance of all Cirrus HD-OCT parameters. Age, axial length and optic disc size were significantly associated with diagnostic accuracy of average peripapillary RNFL thickness, whereas axial length had a significant effect on the diagnostic accuracy of average GCIPL thickness. Conclusions Diagnostic performance of the Cirrus HD-OCT may be more accurate in the advanced stages of glaucoma than at earlier stages. A smaller optic disc size was significantly associated with improved the diagnostic ability of average RNFL thickness measurements; however, GCIPL thickness may be less affected by age and optic disc size. PMID:27490718
Numerical prediction of flow induced fibers orientation in injection molded polymer composites
NASA Astrophysics Data System (ADS)
Oumer, A. N.; Hamidi, N. M.; Mat Sahat, I.
2015-12-01
Since the filling stage of injection molding process has important effect on the determination of the orientation state of the fibers, accurate analysis of the flow field for the mold filling stage becomes a necessity. The aim of the paper is to characterize the flow induced orientation state of short fibers in injection molding cavities. A dog-bone shaped model is considered for the simulation and experiment. The numerical model for determination of the fibers orientation during mold-filling stage of injection molding process was solved using Computational Fluid Dynamics (CFD) software called MoldFlow. Both the simulation and experimental results showed that two different regions (or three layers of orientation structures) across the thickness of the specimen could be found: a shell region which is near to the mold cavity wall, and a core region at the middle of the cross section. The simulation results support the experimental observations that for thin plates the probability of fiber alignment to the flow direction near the mold cavity walls is high but low at the core region. It is apparent that the results of this study could assist in decisions regarding short fiber reinforced polymer composites.
Choi, Dong Yun; An, Eun Jeong; Jung, Soo-Ho; Song, Dong Keun; Oh, Yong Suk; Lee, Hyung Woo; Lee, Hye Moon
2018-04-10
Through the direct decomposition of an Al precursor ink AlH 3 {O(C 4 H 9 ) 2 }, we fabricated an Al-coated conductive fiber filter for the efficient electrostatic removal of airborne particles (>99%) with a low pressure drop (~several Pascals). The effects of the electrical and structural properties of the filters were investigated in terms of collection efficiency, pressure drop, and particle deposition behavior. The collection efficiency did not show a significant correlation with the extent of electrical conductivity, as the filter is electrostatically charged by the metallic Al layers forming electrical networks throughout the fibers. Most of the charged particles were collected via surface filtration by Coulombic interactions; consequently, the filter thickness had little effect on the collection efficiency. Based on simulations of various fiber structures, we found that surface filtration can transition to depth filtration depending on the extent of interfiber distance. Therefore, the effects of structural characteristics on collection efficiency varied depending on the degree of the fiber packing density. This study will offer valuable information pertaining to the development of a conductive metal/polymer composite air filter for an energy-efficient and high-performance electrostatic filtration system.
Penetration of gold nanoparticles across the stratum corneum layer of thick-Skin.
Raju, Gayathri; Katiyar, Neeraj; Vadukumpully, Sajini; Shankarappa, Sahadev A
2018-02-01
Transdermal particulate penetration across thick-skin, such as that of palms and sole, is particularly important for drug delivery for disorders such as small fiber neuropathies. Nanoparticle-based drug delivery across skin is believed to have much translational applications, but their penetration especially through thick-skin, is not clear. This study specifically investigates the effectiveness of gold nanoparticles (AuNPs) for thick-skin penetration, especially across the stratum corneum (SC) as a function of particle size. The thick-skinned hind-paw of rat was used to characterize depth and distribution of AuNPs of varying sizes, namely, 22±3, 105±11, and 186±20nm. Epidermal penetration of AuNPs was characterized both, in harvested skin from the hind-paw using a diffusion chamber, as well as in vivo. Harvested skin segments exposed to 22nm AuNPs for only 3h demonstrated higher penetration (p<0.05) as compared to the 105 and 186nm particles. In animal studies, hind-paw skin of adult rats exposed to AuNPs solution for the same time, demonstrated nanoparticles in blood on the 4th day, and histological analysis revealed AuNPs in epidermal layers just below the SC, with no apparent tissue response. We conclude that the thick-skin allows nanoparticle penetration and acts as a depot for release of AuNPs into circulation long after the initial exposure has ceased. Copyright © 2017 Japanese Society for Investigative Dermatology. Published by Elsevier B.V. All rights reserved.
Nanostructural evolution during emission of CsI-coated carbon fiber cathodes
NASA Astrophysics Data System (ADS)
Drummy, Lawrence F.; Apt, Scott; Shiffler, Don; Golby, Ken; LaCour, Matt; Maruyama, Benji; Vaia, Richard A.
2010-06-01
Carbon-based nanofiber and microfiber cathodes exhibit very low voltages for the onset of electron emission, and thus provide exciting opportunities for applications ranging from high power microwave sources to field emission displays. CsI coatings have been experimentally shown to lower the work function for emission from the fiber tips, although little is known about the microstructure of the fibers themselves in their as-received state, after coating with CsI, or after being subjected to high voltage cycling. Longitudinal cross sections of the original, unused CsI-coated fibers produced by focused ion beam lift-out revealed a nanostructured graphitic core surrounded by an amorphous carbon shell with submicron sized islands of crystalline CsI on the outer surface. Aberration-corrected high resolution electron microscopy (HREM) of the fiber core achieved 0.10 nm resolution, with the graphite (200) clearly visible in digital fast Fourier transformations of the 2-4 nm highly ordered graphitic domains. As the cathode fibers are cycled at high voltage, HREM demonstrates that the graphitic ordering of the core increases with the number of cycles, however the structure and thickness of the amorphous carbon layer remains unchanged. These results are consistent with micro-Raman measurements of the fiber disordered/graphitic (D/G) band ratios. After high voltage cycling, a uniform ˜100 nm film at the fiber tip was evident in both bright field transmission electron microscopy (TEM) and high angle annular dark field scanning TEM (STEM). Low-dose electron diffraction techniques confirmed the amorphous nature of this film, and STEM with elemental mapping via x-ray energy dispersive spectroscopy indicates this layer is composed of CsIO. The oxidative evolution of tip composition and morphology due to impurities in the chamber, along with increased graphitization of the fiber core, contributes to changes in emission behavior with cycling.
Seol, Bo Ram; Kim, Dong Myung; Park, Ki Ho; Jeoung, Jin Wook
2017-11-01
To evaluate the optical coherence tomography (OCT) color probability codes based on a myopic normative database and to investigate whether the implementation of the myopic normative database can improve the OCT diagnostic ability in myopic glaucoma. Comparative validity study. In this study, 305 eyes (154 myopic healthy eyes and 151 myopic glaucoma eyes) were included. A myopic normative database was obtained based on myopic healthy eyes. We evaluated the agreement between OCT color probability codes after applying the built-in and myopic normative databases, respectively. Another 120 eyes (60 myopic healthy eyes and 60 myopic glaucoma eyes) were included and the diagnostic performance of OCT color codes using a myopic normative database was investigated. The mean weighted kappa (Kw) coefficients for quadrant retinal nerve fiber layer (RNFL) thickness, clock-hour RNFL thickness, and ganglion cell-inner plexiform layer (GCIPL) thickness were 0.636, 0.627, and 0.564, respectively. The myopic normative database showed a higher specificity than did the built-in normative database in quadrant RNFL thickness, clock-hour RNFL thickness, and GCIPL thickness (P < .001, P < .001, and P < .001, respectively). The receiver operating characteristic curve values increased when using the myopic normative database in quadrant RNFL thickness, clock-hour RNFL thickness, and GCIPL thickness (P = .011, P = .004, P < .001, respectively). The diagnostic ability of OCT color codes for detection of myopic glaucoma significantly improved after application of the myopic normative database. The implementation of a myopic normative database is needed to allow more precise interpretation of OCT color probability codes when used in myopic eyes. Copyright © 2017 Elsevier Inc. All rights reserved.
Elastic fiber-mediated enthesis in the human middle ear
Kawase, Tetsuaki; Shibata, Shunichi; Katori, Yukio; Ohtsuka, Aiji; Murakami, Gen; Fujimiya, Mineko
2012-01-01
Adaptation to constant vibration (acoustic oscillation) is likely to confer a specific morphology at the bone–tendon and bone–ligament interfaces at the ear ossicles, which therefore represent an exciting target of enthesis research. We histologically examined (i) the bone attachments of the tensor tympani and stapedius muscles and (ii) the annular ligament of the incudostapedial joint obtained from seven elderly donated cadavers. Notably, both aldehyde-fuchsin and elastic-Masson staining demonstrated that the major fibrous component of the entheses was not collagen fibers but mature elastic fibers. The positive controls for elastic fiber staining were the arterial wall elastic laminae included in the temporal bone materials. The elastic fibers were inserted deeply into the type II collagen-poor fibrocartilage covering the ear ossicles. The muscle tendons were composed of an outer thin layer of collagen fibers and an inner thick core of elastic fibers near the malleus or stapes. In the unique elastic fiber-mediated entheses, hyaluronan, versican and fibronectin were expressed strongly along the elastic fibers. The hyaluronan seemed to act as a friction-reducing lubricant for the elastic fibers. Aggrecan was labeled strongly in a disk- or plica-like fibrous mass on the inner side of the elastic fiber-rich ligament, possibly due to compression stress from the ligament. Tenascin-c was not evident in the entheses. The elastic fiber-mediated entheses appeared resistant to tissue destruction in an environment exposed to constant vibration. The morphology was unlikely to be the result of age-related degeneration. PMID:22803514
Deformation and stress response of composite laminated shells under internal pressure
NASA Technical Reports Server (NTRS)
Yuan, F. G.
1991-01-01
This paper presents a theoretical study of the response of filament wound composite shells under internal pressure. Each layer of the material is generally cylindrically anisotropic. By using cylindrically anisotropic elasticity field equations and Lekhnitskii's stress functions, a system of sixth-order ordinary differential equations is obtained. The general expressions for the stresses and displacements in the laminated composite shells under internal pressure are discussed. Two composite systems, graphite/epoxy and glass/epoxy, are selected to demonstrate the influence of degree of material anisotropy and fiber orientations on the axial and induced twisting deformation. Stress distributions of (45/-45)s symmetric angle-ply fiber-reinforced laminated shells are shown to illustrate the effect of radius-to-thickness ratio.
Flight test of carbon-phenolic on a spacecraft launched by the pacemaker vehicle system
NASA Technical Reports Server (NTRS)
Walton, T. E., Jr.; Witte, W. G.
1972-01-01
Carbon-phenolic material consisting of 50 percent carbon fibers and 50 percent phenolic resin was flight tested on a recoverable spacecraft launched by the Pacemaker vehicle system. The heat shield of the spacecraft was fabricated so that the carbon fibers in the ablator material had different orientations over several areas of the spacecraft. The environment in which the spacecraft was tested produced heating rates on the hemispherical nose up to 13.6 MW/sq m (1200 Btu/sq ft/sec) and stagnation-point pressures up to 1.27 MN/sq m (12.5 atm). The experimental results are presented. Due to high heating rates and possible spallation and mechanical char removal the greatest mass loss occurred in the nose region. Essentially uniform surface recession and char thickness were observed on the conical section of the spacecraft. A comparison of measured heating rates with computed turbulent and laminar heating rates, as well as measurements of sound-pressure fluctuations in the boundary layer obtained with acoustic sensors, indicated that the boundary layer underwent transition. The acoustic sensor provides an interesting new data form for the general study of boundary-layer transition for free-flight investigations.
Ocean Engineering Studies Compiled 1991. Volume 11. Pressure-Resistant Glass Light Enclosures
1991-01-01
resting on this gasket than when they were resting on bare type 316 stainless steel end closures, aluminum gasket, or glass fiber- phenolic laminate ...316 2.58 inches thick Brass (naval) 2.58 inches thick Titanium (Ti-6AI-4V) 1.82 inches thick Phenolic resin-glass fiber laminate 4.40 inches thick...The 6061-T6 aluminum and the 94 spcimen s phenolic resin-impregnated glass fiber 18,000 imploded at -- /- laminate materials performed the best 18,000
Luo, Xunda; Patel, Nimesh B.; Rajagopalan, Lakshmi P.; Harwerth, Ronald S.; Frishman, Laura J.
2014-01-01
Purpose. We investigated relations between macular retinal ganglion cell plus inner plexiform layer (RGC+IPL) thickness and macular retinal function revealed by multifocal electroretinonography (mfERG) in a nonhuman primate model of experimental glaucoma. Methods. Retinal ganglion cell (RGC) structure and function were followed with spectral-domain optical coherence tomography (SD-OCT) and ERGs in five macaques with unilateral experimental glaucoma. Linear regression was used to study correlations in control (Con) and experimental (Exp) eyes between peripapillary retinal nerve fiber layer (RNFL) thickness, macular RGC+IPL thickness, multifocal photopic negative response (mfPhNR) and high-frequency multifocal oscillatory potentials (mfOP) in slow-sequence mfERG, and low-frequency component (mfLFC) in global-flash mfERG. We used ANOVA and paired t-tests to compare glaucoma-related mfERG changes between superior and inferior hemifields, foveal hexagon, inner three rings, and four quadrants of macula. Results. Average macular RGC+IPL and temporal RNFL thickness were strongly correlated (r2 = 0.90, P < 0.001). In hexagon-by-hexagon analysis, all three mfERG measures were correlated (P < 0.001) with RGC+IPL thickness for Con (r2, 0.33–0.51) and Exp eyes (r2, 0.17–0.35). The RGC structural and functional metrics decreased as eccentricity increased. The reduction in amplitude of mfERG measures in Exp eyes relative to Con eyes was proportionally greater, in general, than the relative thinning of RGC+IPL at the same location for eyes in which structural loss was not evident, or mild to moderate. Although not statistically significant, percent amplitude reduction of mfERG measures was greatest in the inferior temporal quadrant. Conclusions. Macular RGC+IPL thickness and mfERG measures of RGC function can be complementary tools in assessing glaucomatous neuropathy. PMID:24970256
Laminated Thin Shell Structures Subjected to Free Vibration in a Hygrothermal Environment
NASA Technical Reports Server (NTRS)
Gotsis, Pascal K.; Guptill, James D.
1994-01-01
Parametric studies were performed to assess the effects of various parameters on the free-vibration behavior (natural frequencies) of (+/- theta)(sub 2) angle-ply, fiber composite, thin shell structures in a hygrothermal environment. Knowledge of the natural frequencies of structures is important in considering their response to various kinds of excitation, especially when structures and force systems are complex and when excitations are not periodic. The three dimensional, finite element structural analysis computer code CSTEM was used in the Cray YMP computer environment. The fiber composite shell was assumed to be cylindrical and made from T300 graphite fibers embedded in an intermediate-modulus, high-strength matrix. The following parameters were investigated: the length and the laminate thickness of the shell, the fiber orientation, the fiber volume fraction, the temperature profile through the thickness of the laminate, and laminates with different ply thicknesses. The results indicate that the fiber orientation and the length of the laminated shell had significant effects on the natural frequencies. The fiber volume fraction, the laminate thickness, and the temperature profile through the shell thickness had weak effects on the natural frequencies. Finally, the laminates with different ply thicknesses had an insignificant influence on the behavior of the vibrated laminated shell. Also, a single through-the-thickness, eight-node, three dimensional composite finite element analysis appears to be sufficient for investigating the free-vibration behavior of thin, composite, angle-ply shell structures.
Formation and characterization of asymmetric polyimide hollow fiber membranes for gas separations
NASA Astrophysics Data System (ADS)
Clausi, Dominic Thomas
Ultra-thin and virtually defect-free polyimide hollow fiber membranes were formed using a "dry/wet" type spinning solution. Fibers were spun from the commercially available polyimide, Matrimidsp{°ler}, using a dry-jet, wet quench spinning apparatus. Spin dopes were comprised of volatile and non-volatile solvents, polymer, and non-solvent. The influence of dope composition, spinning parameters, and dehydration procedures on the membrane morphology and performance was investigated. Without post-treatment, the fibers exhibited skin thicknesses less than 1000 A and Osb2/Nsb2 selectivities within 90% of those determined for dense, solution-cast films. The 250 mum O.D./125 mum I.D. fibers were spun at take-up rates comparable to those used in commercial processes and had macrovoid-free morphologies. A new characterization technique has also been developed where a permeating gas is held at constant transmembrane pressure while the average pressure in the porous support of an asymmetric membrane is varied. This alters the mean free path of gas molecules permeating through the substructure while maintaining a constant driving force for permeation. This technique characterizes the magnitude of the substructure resistance and its pressure dependence, thereby providing a means to compare the morphologies of different membrane samples. Well defined composite-laminate membranes were constructed to validate this technique, which was subsequently used to characterize the substructures of the hollow fiber membranes formed in this work. Two additional rapid characterization techniques have been developed for use before fiber dehydration (i.e., wet fibers). These techniques probe the membrane skin layer with aqueous solutions of disperse dyes and poly(ethylene glycol), respectively. Fiber skin integrity can be characterized using these techniques prior to lengthy downstream processing (i.e., solvent exchange, drying, and post-treatment), providing quick elucidation of membrane skin morphology. Finally, a qualitative model describing the skin layer morphology of phase inversion membranes has been developed. This model arose from observed differences in the permeation characteristics of highly sorbing gases between bore and shell side feeds. It is proposed that the skin layer contains an asymmetric distribution of unrelaxed volume introduced during the formation process. This model has been successfully tested with COsb2/CHsb4 permeation measurements conducted at varying temperatures and feed configurations.
Larrosa, Jose M; Polo, Vicente; Ferreras, Antonio; García-Martín, Elena; Calvo, Pilar; Pablo, Luis E
2015-12-01
To compare the diagnostic performance of different segmentations of the nerve fiber layer (NFL) thickness measurements using an artificial neural network and to define the optimal number of sectors with best diagnostic ability for glaucoma diagnosis. A total of 117 glaucoma patients and 123 normal subjects were included in the study. NFL thickness measurements were performed using the Spectralis-OCT (Heidelberg Engineering) to obtain the NFL thickness average; measurements from 2 semicircles, 4 quadrants, and 6, 8, 12, 16, 24, 32, and 64 sectors; and 768 uniformly divided locations around the peripapillary NFL. An artificial neural network evaluation was performed to compare the influence of sector analysis on the diagnostic performance of optical coherence tomography. Receiver operating characteristic curves were used to compare the diagnostic ability of the different segmentation analyses. The 6 sectors divided by the horizontal division of the nasal and temporal quadrants were better than the 6 sectors divided by the vertical line through the superior and inferior quadrants [areas under curve, 0.778; 95% confidence interval (CI), 0.720-0.829 and 0.814; 95% CI, 0.759-0.861, respectively]. In the case of quadrants, clock quadrants (area under curve 0.770; 95% CI, 0.712-0.822) were better than the ISNT (inferior-superior-nasal-temporal) quadrants (area under curve, 0.770; 95% CI, 0.712-0.822; P=0.003). The first segmentation strategy that improved the diagnostic value of 4 ISNT quadrants was the 12-sector analysis (area under curve, 0.845; 95% CI, 0.793-0.889; P=0.001). The 2 best candidate strategies for the OCT report were the 12-sector analysis and the 4 planimetric quadrant (alternatively, the 4 clock quadrants) analysis.
Khoueir, Ziad; Jassim, Firas; Poon, Linda Yi-Chieh; Tsikata, Edem; Ben-David, Geulah S; Liu, Yingna; Shieh, Eric; Lee, Ramon; Guo, Rong; Papadogeorgou, Georgia; Braaf, Boy; Simavli, Huseyin; Que, Christian; Vakoc, Benjamin J; Bouma, Brett E; de Boer, Johannes F; Chen, Teresa C
2017-10-01
To determine the diagnostic capability of peripapillary 3-dimensional (3D) retinal nerve fiber layer (RNFL) volume measurements from spectral-domain optical coherence tomography (OCT) volume scans for open-angle glaucoma (OAG). Assessment of diagnostic accuracy. Setting: Academic clinical setting. Total of 180 patients (113 OAG and 67 normal subjects). One eye per subject was included. Peripapillary 3D RNFL volumes were calculated for global, quadrant, and sector regions, using 4 different-size annuli. Peripapillary 2D RNFL thickness circle scans were also obtained. Area under the receiver operating characteristic curve (AUROC) values, sensitivity, specificity, positive and negative predictive values, positive and negative likelihood ratios. Among all 2D and 3D RNFL parameters, best diagnostic capability was associated with inferior quadrant 3D RNFL volume of the smallest annulus (AUROC value 0.977). Otherwise, global 3D RNFL volume AUROC values were comparable to global 2D RNFL thickness AUROC values for all 4 annulus sizes (P values: .0593 to .6866). When comparing the 4 annulus sizes for global RNFL volume, the smallest annulus had the best AUROC values (P values: .0317 to .0380). The smallest-size annulus may have the best diagnostic potential, partly owing to having no areas excluded for being larger than the 6 × 6 mm 2 scanned region. Peripapillary 3D RNFL volume showed excellent diagnostic performance for detecting glaucoma. Peripapillary 3D RNFL volume parameters have the same or better diagnostic capability compared to peripapillary 2D RNFL thickness measurements, although differences were not statistically significant. Copyright © 2017 Elsevier Inc. All rights reserved.
On the bending properties of porcine mitral, tricuspid, aortic, and pulmonary valve leaflets.
Brazile, Bryn; Wang, Bo; Wang, Guangjun; Bertucci, Robbin; Prabhu, Raj; Patnaik, Sourav S; Butler, J Ryan; Claude, Andrew; Brinkman-Ferguson, Erin; Williams, Lakiesha N; Liao, Jun
2015-01-01
The atrioventricular valve leaflets (mitral and tricuspid) are different from the semilunar valve leaflets (aortic and pulmonary) in layered structure, ultrastructural constitution and organization, and leaflet thickness. These differences warrant a comparative look at the bending properties of the four types of leaflets. We found that the moment-curvature relationships in atrioventricular valves were stiffer than in semilunar valves, and the moment-curvature relationships of the left-side valve leaflets were stiffer than their morphological analog of the right side. These trends were supported by the moment-curvature curves and the flexural rigidity analysis (EI value decreased from mitral, tricuspid, aortic, to pulmonary leaflets). However, after taking away the geometric effect (moment of inertia I), the instantaneous effective bending modulus E showed a reversed trend. The overall trend of flexural rigidity (EI: mitral > tricuspid > aortic > pulmonary) might be correlated with the thickness variations among the four types of leaflets (thickness: mitral > tricuspid > aortic > pulmonary). The overall trend of the instantaneous effective bending modulus (E: mitral < tricuspid < aortic < pulmonary) might be correlated to the layered fibrous ultrastructures of the four types of leaflets, of which the fibers in mitral and tricuspid leaflets were less aligned, and the fibers in aortic and pulmonary leaflets were highly aligned. We also found that, for all types of leaflets, moment-curvature relationships are stiffer in against-curvature (AC) bending than in with-curvature bending (WC), which implies that leaflets tend to flex toward their natural curvature and comply with blood flow. Lastly, we observed that the leaflets were stiffer in circumferential bending compared with radial bending, likely reflecting the physiological motion of the leaflets, i.e., more bending moment and movement were experienced in radial direction than circumferential direction.
Bikbov, M M; Fayzrakhmanov, R R; Kalanov, M R
2018-01-01
To compare morpho-functional parameters of retina during vitrectomy with and without internal limiting membrane (ILM) peeling in patients with proliferative diabetic retinopathy. The study included 55 patients (55 eyes) that had underwent vitreoretinal surgery in the setting of antivasoproliferative therapy for proliferative diabetic retinopathy. Patients of the 1 st group (n=27) underwent vitrectomy with silicone tamponade, 2 nd group (n=28) received similar treatment with the addition of ILM peeling. Three months after the treatment, all patients had silicone oil removed. Best Corrected Visual Acuity before treatment was 0.06±0.02 in both groups; after the treatment it improved to 0.1±0.05 (p<0.05) in the 1 st group and to 0.25±0.05 (p 1-2 <0.05) in the 2 nd group. Thickness of the 'nerve fiber layer - internal limiting membrane' in the macular area was 28.67±2.21 µm in both groups before the treatment. By 3-month follow-up its thickness increased to 46.44±2.56 µm (p<0.05) in the 1 st group due to the formation of epiretinal membrane (ERM). In patients of the 2 nd group 'nerve fiber layer' area thickness amounted to 28.41±1.88 µm (p 1-2 <0.05) and ERM could not be identified in any of them. ILM peeling during vitrectomy with following silicone oil tamponade eliminates the risk of ERM formation in patients with proliferative diabetic retinopathy in the follow-up period of up to 6-month and results in better morpho-functional parameters in comparison with patients who received similar treatment but without peeling.
Effect of kenaf fiber in reinforced concrete slab
NASA Astrophysics Data System (ADS)
Syed Mohsin, S. M.; Baarimah, A. O.; Jokhio, G. A.
2018-04-01
The effect of kenaf fibers in reinforced concrete slab with different thickness is discusses and presented in this paper. Kenaf fiber is a type of natural fiber and is added in the reinforced concrete slab to improve the structure strength and ductility. For this study, three types of mixtures were prepared with fiber volume fraction of 0%, 1% and 2%, respectively. The design compressive strength considered was 20 MPa. Six cubes were prepared to be tested at 7th and 28th day. A total of six reinforced concrete slab with two variances of thickness were also prepared and tested under four-point bending test. The differences in the thickness is to study the potential of kenaf fiber to serve as part of shear reinforcement in reinforced concrete slab that was design to fail in shear. It was observed that, addition of kenaf fiber in reinforced concrete slab improves the flexural strength and ductility of the reinforced concrete slab. In the slab with reduction in thickness, the mode of failure change from brittle to ductile with the inclusion of kenaf fiber.
Rebolleda, Gema; Pérez-Sarriegui, Ane; Díez-Álvarez, Laura; De Juan, Victoria; Muñoz-Negrete, Francisco J
2018-06-01
To compare the optic nerve head morphology among primary open-angle glaucoma, non-arteritic anterior ischemic optic neuropathy eyes, their fellow healthy eyes and control eyes, using spectral-domain optical coherence tomography with enhanced depth imaging. Observational cross-sectional study including 88 eyes of 68 patients. In this study, 23 non-arteritic anterior ischemic optic neuropathy eyes, 17 fellow unaffected eyes, 25 primary open-angle glaucoma eyes, and 23 age-matched control eyes were included. Peripapillary retinal nerve fiber layer thickness and optic disk area were evaluated. Bruch's membrane opening diameter, optic cup depth, anterior lamina cribrosa depth, and prelaminar tissue thickness were assessed. Non-arteritic anterior ischemic optic neuropathy and primary open-angle glaucoma eyes had similar visual field mean deviation and peripapillary retinal nerve fiber layer thickness (P = 0.6 and P = 0.56, respectively). Bruch's membrane opening diameter was significantly larger in primary open-angle glaucoma eyes than in control eyes (P = 0.02). Lamina cribrosa and disk cup were deeper in eyes with primary open-angle glaucoma than both control and non-arteritic anterior ischemic optic neuropathy eyes (P < 0.001). Prelaminar tissue thickness was significantly thinner in primary open-angle glaucoma eyes than in non-arteritic anterior ischemic optic neuropathy eyes (P < 0.001). Lamina cribrosa was shallower in both non-arteritic anterior ischemic optic neuropathy and unaffected fellow eyes compared to healthy eyes (P < 0.001 and P = 0.04, respectively). No differences were found in the optic disk area. A forward lamina cribrosa placement and not a smaller disk could be involved in the pathogenesis of non-arteritic anterior ischemic optic neuropathy. A significantly larger Bruch's membrane opening diameter was found in primary open-angle glaucoma eyes compared with control eyes. This issue has clinical implications because Bruch's membrane opening has been considered a stable reference for disk-related measures.
Sobacı, Güngör; Güngör, Rıza; Özge, Gökhan
2013-01-01
AIM To determine the effect of multiple injections of ranibizumab or bevacizumab on retinal nerve fiber layer (RNFL) and intraocular pressure (IOP) in patients with age-related macular degeneration (AMD). METHODS This retrospective study includes 35 eyes of 35 patients treated with intravitreal bevacizumab (IVB, 1.25mg/0.05mL) and 30 eyes of 30 patients with intravitreal ranibizumab (IVR, 0.5mg/0.05mL) who had Fast RNFL analysis (Stratus™); IOP measurements were taken 30 minutes and 24 hours after each injection. RESULTS The mean ages were 68.0±7.5 and 69.1±7.7 years in the IVR and IVB groups, respectively (P=0.55). They underwent (6.3±1.9) and (5.1±1.3) injections (P=0.07) over (13.6±2.1) and (14.05±2.6) months (P=0.45) in the IVR and IVB groups, respectively. Changes in overall and temporal RNFL thickness in IVR-treated eyes (105.3±6.9µm and 74.4±11.2µm) were not different from those in untreated eyes in the IVR group (104.6± 8.4µm and 75.1±12.6µm) (P=0.57 and P=0.41, respectively). Similarly, overall and temporal RNFL thickness in IVB-treated eyes (105.8±8.1µm and 74.5±11.8µm) were not different from those in untreated eyes in the IVB group (104.6±8µm and 74.8±12.9µm) (P=0.42 and P=0.80, respectively). The frequencies of IOP rise (P=0.60) and changes in RNFL thickness from baseline (P=0.16) were comparable between groups. CONCLUSION Repeated intravitreal injection of ranibizumab or bevacizumab does not seem have adverse effects on RNFL thickness or IOP in wet AMD patients. PMID:23638426
Sobacı, Güngör; Güngör, Rıza; Ozge, Gökhan
2013-01-01
To determine the effect of multiple injections of ranibizumab or bevacizumab on retinal nerve fiber layer (RNFL) and intraocular pressure (IOP) in patients with age-related macular degeneration (AMD). This retrospective study includes 35 eyes of 35 patients treated with intravitreal bevacizumab (IVB, 1.25mg/0.05mL) and 30 eyes of 30 patients with intravitreal ranibizumab (IVR, 0.5mg/0.05mL) who had Fast RNFL analysis (Stratus™); IOP measurements were taken 30 minutes and 24 hours after each injection. The mean ages were 68.0±7.5 and 69.1±7.7 years in the IVR and IVB groups, respectively (P=0.55). They underwent (6.3±1.9) and (5.1±1.3) injections (P=0.07) over (13.6±2.1) and (14.05±2.6) months (P=0.45) in the IVR and IVB groups, respectively. Changes in overall and temporal RNFL thickness in IVR-treated eyes (105.3±6.9µm and 74.4±11.2µm) were not different from those in untreated eyes in the IVR group (104.6± 8.4µm and 75.1±12.6µm) (P=0.57 and P=0.41, respectively). Similarly, overall and temporal RNFL thickness in IVB-treated eyes (105.8±8.1µm and 74.5±11.8µm) were not different from those in untreated eyes in the IVB group (104.6±8µm and 74.8±12.9µm) (P=0.42 and P=0.80, respectively). The frequencies of IOP rise (P=0.60) and changes in RNFL thickness from baseline (P=0.16) were comparable between groups. Repeated intravitreal injection of ranibizumab or bevacizumab does not seem have adverse effects on RNFL thickness or IOP in wet AMD patients.
NASA Astrophysics Data System (ADS)
Yao, Xuan; Wang, Yuanbo; Ravanfar, Mohammadreza; Pfeiffer, Ferris M.; Duan, Dongsheng; Yao, Gang
2016-11-01
Collagen fiber orientation plays an important role in determining the structure and function of the articular cartilage. However, there is currently a lack of nondestructive means to image the fiber orientation from the cartilage surface. The purpose of this study is to investigate whether the newly developed optical polarization tractography (OPT) can image fiber structure in articular cartilage. OPT was applied to obtain the depth-dependent fiber orientation in fresh articular cartilage samples obtained from porcine phalanges. For comparison, we also obtained collagen fiber orientation in the superficial zone of the cartilage using the established split-line method. The direction of each split-line was quantified using image processing. The orientation measured in OPT agreed well with those obtained from the split-line method. The correlation analysis of a total of 112 split-lines showed a greater than 0.9 coefficient of determination (R2) between the split-line results and OPT measurements obtained between 40 and 108 μm in depth. In addition, the thickness of the superficial layer can also be assessed from the birefringence images obtained in OPT. These results support that OPT provides a nondestructive way to image the collagen fiber structure in articular cartilage. This technology may be valuable for both basic cartilage research and clinical orthopedic applications.
Zhi, Zhongwei; Chao, Jennifer R.; Wietecha, Tomasz; Hudkins, Kelly L.; Alpers, Charles E.; Wang, Ruikang K.
2014-01-01
Purpose. To evaluate early diabetes-induced changes in retinal thickness and microvasculature in a type 2 diabetic mouse model by using optical coherence tomography (OCT)/optical microangiography (OMAG). Methods. Twenty-two-week-old obese (OB) BTBR mice (n = 10) and wild-type (WT) control mice (n = 10) were imaged. Three-dimensional (3D) data volumes were captured with spectral domain OCT using an ultrahigh-sensitive OMAG scanning protocol for 3D volumetric angiography of the retina and dense A-scan protocol for measurement of the total retinal blood flow (RBF) rate. The thicknesses of the nerve fiber layer (NFL) and that of the NFL to the inner plexiform layer (IPL) were measured and compared between OB and WT mice. The linear capillary densities within intermediate and deep capillary layers were determined by the number of capillaries crossing a 500-μm line. The RBF rate was evaluated using an en face Doppler approach. These quantitative measurements were compared between OB and WT mice. Results. The retinal thickness of the NFL to IPL was significantly reduced in OB mice (P < 0.01) compared to that in WT mice, whereas the NFL thickness between the two was unchanged. 3D depth-resolved OMAG angiography revealed the first in vivo 3D model of mouse retinal microcirculation. Although no obvious differences in capillary vessel densities of the intermediate and deep capillary layers were detected between normal and OB mice, the total RBF rate was significantly lower (P < 0.05) in OB mice than in WT mice. Conclusions. We conclude that OB BTBR mice have significantly reduced NFL–IPL thicknesses and total RBF rates compared with those of WT mice, as imaged by OCT/OMAG. OMAG provides an unprecedented capability for high-resolution depth-resolved imaging of mouse retinal vessels and blood flow that may play a pivotal role in providing a noninvasive method for detecting early microvascular changes in patients with diabetic retinopathy. PMID:24458155
Yang, Zhiyong; Tatham, Andrew J; Weinreb, Robert N; Medeiros, Felipe A; Liu, Ting; Zangwill, Linda M
2015-01-01
To evaluate the diagnostic ability of macular ganglion cell and inner plexiform layer measurements in glaucoma, obtained using swept source (SS) and spectral domain (SD) optical coherence tomography (OCT) and to compare to circumpapillary retinal nerve fiber layer (cpRNFL) thickness measurements. The study included 106 glaucomatous eyes of 80 subjects and 41 eyes of 22 healthy subjects from the Diagnostic Innovations in Glaucoma Study. Macular ganglion cell and inner plexiform layer (mGCIPL), macular ganglion cell complex (mGCC) and cpRNFL thickness were assessed using SS-OCT and SD-OCT, and area under the receiver operating characteristic curves (AUCs) were calculated to determine ability to differentiate glaucomatous and healthy eyes and between early glaucomatous and healthy eyes. Mean (± standard deviation) mGCIPL and mGCC thickness were thinner in both healthy and glaucomatous eyes using SS-OCT compared to using SD-OCT. Fixed and proportional biases were detected between SS-OCT and SD-OCT measures. Diagnostic accuracy (AUCs) for differentiating between healthy and glaucomatous eyes for average and sectoral mGCIPL was similar in SS-OCT (0.65 to 0.81) and SD-OCT (0.63 to 0.83). AUCs for average cpRNFL acquired using SS-OCT and SD-OCT tended to be higher (0.83 and 0.85, respectively) than for average mGCC (0.82 and 0.78, respectively), and mGCIPL (0.73 and 0.75, respectively) but these differences did not consistently reach statistical significance. Minimum SD-OCT mGCIPL and mGCC thickness (unavailable in SS-OCT) had the highest AUC (0.86) among macular measurements. Assessment of mGCIPL thickness using SS-OCT or SD-OCT is useful for detecting glaucomatous damage, but measurements are not interchangeable for patient management decisions. Diagnostic accuracies of mGCIPL and mGCC from both SS-OCT and SD-OCT were similar to that of cpRNFL for glaucoma detection.
Yang, Zhiyong; Tatham, Andrew J.; Weinreb, Robert N.; Medeiros, Felipe A.; Liu, Ting; Zangwill, Linda M.
2015-01-01
Purpose To evaluate the diagnostic ability of macular ganglion cell and inner plexiform layer measurements in glaucoma, obtained using swept source (SS) and spectral domain (SD) optical coherence tomography (OCT) and to compare to circumpapillary retinal nerve fiber layer (cpRNFL) thickness measurements. Methods The study included 106 glaucomatous eyes of 80 subjects and 41 eyes of 22 healthy subjects from the Diagnostic Innovations in Glaucoma Study. Macular ganglion cell and inner plexiform layer (mGCIPL), macular ganglion cell complex (mGCC) and cpRNFL thickness were assessed using SS-OCT and SD-OCT, and area under the receiver operating characteristic curves (AUCs) were calculated to determine ability to differentiate glaucomatous and healthy eyes and between early glaucomatous and healthy eyes. Results Mean (± standard deviation) mGCIPL and mGCC thickness were thinner in both healthy and glaucomatous eyes using SS-OCT compared to using SD-OCT. Fixed and proportional biases were detected between SS-OCT and SD-OCT measures. Diagnostic accuracy (AUCs) for differentiating between healthy and glaucomatous eyes for average and sectoral mGCIPL was similar in SS-OCT (0.65 to 0.81) and SD-OCT (0.63 to 0.83). AUCs for average cpRNFL acquired using SS-OCT and SD-OCT tended to be higher (0.83 and 0.85, respectively) than for average mGCC (0.82 and 0.78, respectively), and mGCIPL (0.73 and 0.75, respectively) but these differences did not consistently reach statistical significance. Minimum SD-OCT mGCIPL and mGCC thickness (unavailable in SS-OCT) had the highest AUC (0.86) among macular measurements. Conclusion Assessment of mGCIPL thickness using SS-OCT or SD-OCT is useful for detecting glaucomatous damage, but measurements are not interchangeable for patient management decisions. Diagnostic accuracies of mGCIPL and mGCC from both SS-OCT and SD-OCT were similar to that of cpRNFL for glaucoma detection. PMID:25978420
Metal/fiber laminate and fabrication using a porous metal/fiber preform
NASA Technical Reports Server (NTRS)
Hales, Stephen J. (Inventor); Alexa, Joel A. (Inventor); Jensen, Brian J. (Inventor); Cano, Roberto J. (Inventor); Weiser, Erik S. (Inventor)
2011-01-01
A metal/fiber laminate has a plurality of adjacent layers. Each layer is porous and includes an arrangement of fibers. At least one of the layers has its fibers coated with a metal. A polymer matrix permeates each such arrangement.
Metal/fiber laminate and fabrication using a porous metal/fiber preform
NASA Technical Reports Server (NTRS)
Hales, Stephen J. (Inventor); Alexa, Joel A. (Inventor); Jensen, Brian J. (Inventor); Cano, Roberto J. (Inventor); Weiser, Erik S. (Inventor)
2010-01-01
A metal/fiber laminate has a plurality of adjacent layers. Each layer is porous and includes an arrangement of fibers. At least one of the layers has its fibers coated with a metal. A polymer matrix permeates each such arrangement.
Methods of making wind turbine rotor blades
Livingston, Jamie T.; Burke, Arthur H. E.; Bakhuis, Jan Willem; Van Breugel, Sjef; Billen, Andrew
2008-04-01
A method of manufacturing a root portion of a wind turbine blade includes, in an exemplary embodiment, providing an outer layer of reinforcing fibers including at least two woven mats of reinforcing fibers, providing an inner layer of reinforcing fibers including at least two woven mats of reinforcing fibers, and positioning at least two bands of reinforcing fibers between the inner and outer layers, with each band of reinforcing fibers including at least two woven mats of reinforcing fibers. The method further includes positioning a mat of randomly arranged reinforcing fibers between each pair of adjacent bands of reinforcing fibers, introducing a polymeric resin into the root potion of the wind turbine blade, infusing the resin through the outer layer, the inner layer, each band of reinforcing fibers, and each mat of random reinforcing fibers, and curing the resin to form the root portion of the wind turbine blade.
NASA Astrophysics Data System (ADS)
Ko, Tony H.; Hartl, Ingmar; Drexler, Wolfgang; Ghanta, Ravi K.; Fujimoto, James G.
2002-06-01
Quantitative, three-dimensional mapping of retinal architectural morphology was achieved using an ultrahigh resolution ophthalmic OCT system. This OCT system utilizes a broad bandwidth titanium-sapphire laser light source generating bandwidths of up to 300 nm near 800 nm center wavelength. The system enables real-time cross-sectional imaging of the retina with ~3 micrometers axial resolution. The macula and the papillomacular axis of a normal human subject were systematically mapped using a series of linear scans. Edge detection and segmentation algorithms were developed to quantify retinal and intraretinal thicknesses. Topographic mapping of the total retinal thickness and the total ganglion cell/inner plexiform layer thickness was achieved around the macula. A topographic mapping quantifying the progressive thickening of the nerve fiber layer (NFL) nasally approaching the optic disk was also demonstrated. The ability to create three-dimensional topographic mapping of retinal architectural morphology at ~3 micrometers axial resolution will be relevant for the diagnosis of many retinal diseases. The topographic quantification of these structures can serve as a powerful tool for developing algorithms and clinical scanning protocols for the screening and staging of ophthalmic diseases such as glaucoma.
NASA Astrophysics Data System (ADS)
Epting, William K.; Litster, Shawn
2016-02-01
Although polymer electrolyte fuel cells (PEFCs) offer promise as efficient, low emission power sources, the large amount of platinum catalyst used for the cathode's oxygen reduction (ORR) results in high costs. One approach to using less Pt is to increase the oxygen concentration at the catalyst by reducing the oxygen transport resistances. An important resistance is that of the diffusion media (DM). The DM are highly heterogeneous porous carbon fiber substrates with a graded composition of additives across their thickness. In this work we use an oxygen microsensor with a micro-positioning system to measure the oxygen concentration and presence of liquid water in the pores at discrete points across the thickness of a commercial carbon felt DM in operating PEFCs. Under conditions with no liquid water, the DM accounts for 60% of the oxygen depletion, with 60-70% of that depletion being due to the thin microporous layer (MPL) on the catalyst layer (CL) side. Using concentration gradient data, we quantify the non-uniform local transport resistance across the DM and relate it to high resolution 3D X-ray computed tomography of the same DM.
Ultrahigh sensitivity refractive index sensor of a D-shaped PCF based on surface plasmon resonance.
Wu, JunJun; Li, Shuguang; Wang, Xinyu; Shi, Min; Feng, Xinxing; Liu, Yundong
2018-05-20
We propose a D-shaped photonic crystal fiber (PCF) refractive index sensor with ultrahigh sensitivity and a wide detection range. The gold layer is deposited on the polished surface, avoiding filling or coating inside the air holes of the PCF. The influences of the gold layer thickness and the diameter of the larger air holes are investigated. The sensing characteristics of the proposed sensor are analyzed by the finite element method. The maximum sensitivity can reach 31,000 nm/RIU, and the refractive index detection range is from 1.32 to 1.40. Our proposed PCF has excellent sensing characteristics and is competitive in sensing devices.
Fabrication process for polymer PLC platforms with V-grooves for passive alignment
NASA Astrophysics Data System (ADS)
Park, Suntak; Lee, Jong-Moo; Ahn, Joon Tae; Baek, Yong-Soon
2005-12-01
A method for polymer planar lightwave circuit (PLC) devices fabricated on a substrate with V-grooves is developed for passive alignment of an optical fiber to a polymer waveguide. In order to minimize thickness nonuniformity of polymer layers caused by the V-grooves, dry film resist (DFR) is used. The V-grooves are covered with the DFR before the polymer layers are spin-coated on the substrate. The DFR prevents the polymer from being filled in the V-grooves as well as from being spin-coated nonuniformly on the substrate. This process provides a simple and cost-effective fabrication method of polymer PLCs or platforms for passive alignment.
Souza-Silva, Érica A; Gionfriddo, Emanuela; Shirey, Robert; Sidisky, Len; Pawliszyn, Janusz
2016-05-12
The main quest for the implementation of direct SPME to complex matrices has been the development of matrix compatible coatings that provide sufficient sensitivity towards the target analytes. In this context, we present here a thorough evaluation of PDMS-overcoated fibers suitable for simultaneous extraction of different polarities analytes, while maintaining adequate matrix compatibility. For this, eleven analytes were selected, from various application classes (pesticides, industrial chemicals and pharmaceuticals) and with a wide range of log P values (ranging from 1.43 to 6). The model matrix chosen was commercial Concord grape juice, which is rich in pigments such as anthocyanins, and contains approximately 20% of sugar (w/w). Two types of PDMS, as well as other intrinsic factors associated with the PDMS-overcoated fiber fabrication are studied. The evaluation showed that the PDMS-overcoated fibers considerably slowed down the coating fouling process during direct immersion in complex matrices of high sugar content. Longevity differences could be seen between the two types of PDMS tested, with a proprietary Sylgard(®) giving superior performance because of lesser amount of reactive groups and enhanced hydrophobicity. Conversely, the thickness of the outer layer did not seem to have a significant effect on the fiber lifetime. We also demonstrate that the uniformity of the overcoated PDMS layer is paramount to the achievement of reliable data and extended fiber lifetime. Employing the optimum overcoated fiber, limits of detection (LOD) in the range of 0.2-1.3 ng/g could be achieved. Additional improvement is attainable by introducing washing of the coatings after desorption, so that any carbon build-up (fouling) left on the coating surface after thermal desorption can be removed. Copyright © 2016 Elsevier B.V. All rights reserved.
The Solar Shield: A Thermally Insulating, Broad-Band, Electromagnetic Window for Satellites
1986-06-02
1.2 but is difficult to machine to thicknesses less than about 1/4 in. without breakage. The one disadvantage of the quartz paper is that it is somewhat...flimsy. Additional structural S•.support was provided by fusing one side of the paper to FEP teflon-coated Kapton* in a laminat - ing press. Kapton...loose quartz fibers from escaping. .4.’ A non-outgassing, polyester netting+ was chosen to separate the composite layers from eachother. * DuPont Corp
Chen, Ming-biao; Ma, Min; Yang, Qing-xiang; Wang, Shan; Liu, Wen-chang; Zhao, Ying-mei
2013-09-01
To provide gist of DC AA 5052 and CC AA 5052 aluminum alloy to industry production and application, the texture variation of cold rolled sheets through thickness direction was studied by X-ray diffraction method, and the difference in texture at surface, quarter and center layer was analyzed. The hot plates of direct chill cast (DC) AA 5052 and continuous cast (CC) AA 5052 aluminum alloy were annealed at 454 degrees C for 4 hours and then cold rolled to different reductions. The strength and volume fraction of the fiber in CC AA 5052 aluminum alloy is larger than in DC AA 5052 aluminum alloy after same rolling reduction The volume fraction of the recrystallization texture cube in the CC AA 5052 aluminum alloy is less than in the DC AA 5052 aluminum alloy, which result in that CC AA 5052 aluminum alloy needs less cold rolling reduction than DC AA 5052 aluminum alloy for generating the texture with same intensity and volume fraction at surface layer, quarter layer and center layer. The manufacturability and performance of CC AA 5052 aluminum alloy is superior to DC AA 5052 aluminum alloy for use in stamping.
Gracitelli, Carolina P. B.; Tatham, Andrew J.; Zangwill, Linda M.; Weinreb, Robert N.; Abe, Ricardo Y.; Diniz-Filho, Alberto; Paranhos, Augusto; Baig, Saif; Medeiros, Felipe A.
2016-01-01
Purpose We examined the relationship between relative afferent pupillary defects (RAPDs) and macular structural damage measured by macular thickness and macular ganglion cell-inner plexiform layer (mGCIPL) thickness in patients with glaucoma. Methods A cross-sectional study was done of 106 glaucoma patients and 85 healthy individuals from the Diagnostic Innovations in Glaucoma Study. All subjects underwent standard automated perimetry (SAP) and optic nerve and macular imaging using Cirrus Spectral Domain Optical Coherence Tomography (SDOCT). Glaucoma was defined as repeatable abnormal SAP or progressive glaucomatous changes on stereo photographs. Pupil responses were assessed using an automated pupillometer, which records the magnitude of RAPD (RAPD score), with additional RAPD scores recorded for each of a series of colored stimuli (blue, red, green, and yellow). The relationship between RAPD score and intereye differences (right minus left eye) in circumpapillary retinal nerve fiber layer (cpRNFL) thickness, mGCIPL, macular thickness, and SAP mean deviation (MD), was examined using linear regression. Results There was fair correlation between RAPD score and asymmetric macular structural damage measured by intereye difference in mGCIPL thickness (R2 = 0.285, P < 0.001). The relationship between RAPD score and intereye difference in macular thickness was weaker (R2 = 0.167, P < 0.001). Intereye difference in cpRNFL thickness (R2 = 0.350, P < 0.001) and SAP MD (R2 = 0.594, P < 0.001) had stronger association with RAPD scores compared to intereye difference in mGCIPL and macular thickness. Conclusions Objective assessment of pupillary responses using a pupillometer was associated with asymmetric macular structural damage in patients with glaucoma. PMID:27064394
Suh, Min Hee; Zangwill, Linda M.; Manalastas, Patricia Isabel C.; Belghith, Akram; Yarmohammadi, Adeleh; Medeiros, Felipe A.; Diniz-Filho, Alberto; Saunders, Luke J.; Weinreb, Robert N.
2016-01-01
Purpose To investigate factors associated with dropout of the deep retinal layer microvasculature within the β-zone parapapillary atrophy (βPPA) assessed by optical coherence tomography angiography (OCT-A) in glaucomatous eyes. Design Cross-sectional study. Participants Seventy-one eyes from 71 primary open angle glaucoma (POAG) patients with βPPA enrolled in the Diagnostic Innovations in Glaucoma Study. Methods βPPA deep layer microvasculature dropout was defined as a complete loss of the microvasculature located within deep retinal layer of the βPPA from OCT-A-derived optic nerve head vessel density maps by standardized qualitative assessment. Circumpapillary vessel density (cpVD) within the retinal nerve fiber layer (RNFL) was also calculated using OCT-A. Choroidal thickness and presence of the focal lamina cribrosa (LC) defect were determined using swept-source OCT. Main Outcome Measures Presence of the βPPA deep layer microvasculature dropout. Parameters including age, systolic and diastolic blood pressure, axial length, intraocular pressure, disc hemorrhage, cpVD, visual field (VF) mean deviation (MD), focal LC defect, βPPA area, and choroidal thickness were analyzed. Results βPPA deep layer microvasculature dropout was detected in 37 eyes (52.1%) of eyes with POAG. Eyes with dropouts had a higher prevalence of LC defect (70.3 vs. 32.4%), lower cpVD (52.7 vs. 58.8%), worse VF MD (-9.06 vs. -3.83dB), thinner total choroidal thickness (126.5 vs. 169.1/μm), longer axial length (24.7 vs. 24.0mm), larger βPPA (1.2 vs. 0.76mm2) and lower diastolic blood pressure (74.7 vs. 81.7mmHg) than those without dropouts (P< 0.05, respectively). In the multivariate logistic regression, higher prevalence of focal LC defect (odds ratio [OR], 6.27; P = 0.012), reduced cpVD (OR, 1.27; P = 0.002), worse VF MD (OR, 1.27; P = 0.001), thinner choroidal thickness (OR, 1.02; P = 0.014), and lower diastolic blood pressure (OR, 1.16; P = 0.003) were significantly associated with the dropout. Conclusions Certain systemic and ocular factors such as focal LC defect, more advanced disease status, reduced RNFL vessel density, thinner choroidal thickness, and lower diastolic blood pressure were factors associated with the βPPA deep layer microvasculature dropout in glaucomatous eyes. Longitudinal studies are required to elucidate the temporal relationship between βPPA deep layer dropout and these factors. PMID:27769587
Suh, Min Hee; Zangwill, Linda M; Manalastas, Patricia Isabel C; Belghith, Akram; Yarmohammadi, Adeleh; Medeiros, Felipe A; Diniz-Filho, Alberto; Saunders, Luke J; Weinreb, Robert N
2016-12-01
To investigate factors associated with dropout of the parapapillary deep retinal layer microvasculature assessed by optical coherence tomography angiography (OCTA) in glaucomatous eyes. Cross-sectional study. Seventy-one eyes from 71 primary open-angle glaucoma (POAG) patients with β-zone parapapillary atrophy (βPPA) enrolled in the Diagnostic Innovations in Glaucoma Study. Parapapillary deep-layer microvasculature dropout was defined as a complete loss of the microvasculature located within the deep retinal layer of the βPPA from OCTA-derived optic nerve head vessel density maps by standardized qualitative assessment. Circumpapillary vessel density (cpVD) within the retinal nerve fiber layer (RNFL) also was calculated using OCTA. Choroidal thickness and presence of focal lamina cribrosa (LC) defects were determined using swept-source optical coherence tomography. Presence of parapapillary deep-layer microvasculature dropout. Parameters including age, systolic and diastolic blood pressure, axial length, intraocular pressure, disc hemorrhage, cpVD, visual field (VF) mean deviation (MD), focal LC defects βPPA area, and choroidal thickness were analyzed. Parapapillary deep-layer microvasculature dropout was detected in 37 POAG eyes (52.1%). Eyes with microvasculature dropout had a higher prevalence of LC defects (70.3% vs. 32.4%), lower cpVD (52.7% vs. 58.8%), worse VF MD (-9.06 dB vs. -3.83 dB), thinner total choroidal thickness (126.5 μm vs. 169.1 μm), longer axial length (24.7 mm vs. 24.0 mm), larger βPPA (1.2 mm 2 vs. 0.76 mm 2 ), and lower diastolic blood pressure (74.7 mmHg vs. 81.7 mmHg) than those without dropout (P < 0.05, respectively). In the multivariate logistic regression analysis, higher prevalence of focal LC defects (odds ratio [OR], 6.27; P = 0.012), reduced cpVD (OR, 1.27; P = 0.002), worse VF MD (OR, 1.27; P = 0.001), thinner choroidal thickness (OR, 1.02; P = 0.014), and lower diastolic blood pressure (OR, 1.16; P = 0.003) were associated significantly with the dropout. Systemic and ocular factors including focal LC defects more advanced glaucoma, reduced RNFL vessel density, thinner choroidal thickness, and lower diastolic blood pressure were factors associated with the parapapillary deep-layer microvasculature dropout in glaucomatous eyes. Longitudinal studies are required to elucidate the temporal relationship between parapapillary deep-layer microvasculature dropout and systemic and ocular factors. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
A unique skeletal microstructure of the deep-sea micrabaciid scleractinian corals
NASA Astrophysics Data System (ADS)
Janiszewska, Katarzyna; Stolarski, Jaroslaw; Benzerara, Karim; Meibom, Anders; Mazur, Maciej; Kitahara, Marcelo; Cairns, Stephen D.
2010-05-01
Structural and biogeochemical properties of the skeleton of many invertebrates rely on organic matrix-mediated biomineralization processes. Organic matrices, composed of complex assemblages of macromolecules (proteins, polysaccharides), may control nucleation, spatial delineation and organization of basic microstructural units. Biologically controlled mineralization is also suggested for the scleractinian corals whose different, molecularly recognized clades are supported by distinct types of skeletal microstructures. Main differences in scleractinian coral skeletal microstructures suggested so far consist in (1) varying spatial relationships between Rapid Accretion Deposits (RAD, 'centers of calcification') and thickening deposits (TD, 'fibers'), and (2) varying arrangements of biomineral fibers into higher order structures (e.g., bundles of fibers perpendicular to skeletal surfaces in some 'caryophylliid' corals vs. scale-like units with fibers parallel to the surface in acroporiids). However, a common feature of biomineral fibers in corals described thus far was their similar crystallographic arrangement within larger meso-scale structures (bundles of fibers) and continuity between successive growth layers. Herein we show that representatives of the deep-sea scleractinian family Micrabaciidae (genera: Letepsammia, Rhombopsammia, Stephanophyllia, Leptopenus) have thickening deposits composed of irregular meshwork of short (1-2 μm) and extremely thin (ca. 100-300 nm) fibers organized into small bundles (ca. 1-2 μm thick). Longer axes of fibers are aligned within individual bundles that, in turn, show rather irregular arrangement on the growing surfaces and within the skeleton (irregular criss-cross pattern). In contrast to other scleractinians (including deep-water 'caryophylliids', fungiacyathids, and anthemiphyllids sympatric with micrabaciids), growth layers are not distinct. Also the regions of rapid accretion and thickening deposits are not clearly separated at the meso-scale. However, AFM and FESEM observations of RAD show nanogranular units (ca. 30-100 nm in diameter) typical of fast growing skeletal regions. Unique microstructural organization of the micrabaciid skeleton supports their monophyletic status (reinforced by macromorphological and molecular data), and points to a diversity of organic matrix-mediated biomineralization strategies in Scleractinia.
Amanullah, Sarah; Okudolo, Joseph; Rahmatnejad, Kamran; Lin, Shuai-Chun; Wizov, Sheryl S; Manzi Muhire, Remy S; Hark, Lisa A; Zheng, Cindy X; Zhan, Tingting; Spaeth, George L
2017-12-01
To evaluate the correlation between contrast sensitivity (CS) and retinal nerve fiber layer (RNFL) in different areas of vision. This report is a sub-analysis of a prospective, observational cohort study investigating changes in performance-based assessment, vision-related quality of life, and clinical measures in patients with moderate to advanced glaucoma. The study included 161 participants with at least a 2-year history of glaucoma who underwent annual testing for 4 years. Contrast sensitivity was measured using the Spaeth/Richman contrast sensitivity (SPARCS) test, while RNFL thickness (RNFLT) was measured using Cirrus optical coherence tomography (OCT). Statistical analyses were performed to determine correlations between CS and RNFLT; the correlations were calculated for each annual visit, totaling four correlation coefficients for each patient over the course of 4 years. The SPARCS score in the left upper area of vision correlated the most strongly with the RNFLT of the inferior quadrant for both eyes at each annual visit, specifically in the seven o'clock sector for the left eye and the six o'clock sector for the right eye (p < 0.05). There were no discernible trends for the correlations between the other areas of CS and RNFL quadrants or clock hours over the 4 years of the study. Linear regression between the SPARCS total score and average RNFLT showed a significant direct correlation at each visit (p < 0.01). Contrast sensitivity in the left upper area of vision for both eyes correlated most strongly with the thickness of the inferior quadrant of the RNFL. These fibers project to the temporal portion of the right occipital lobe, implying a potential center for contrast perception in this area. The longitudinal nature of the study suggests that CS may be a predictive tool for changes in RNFL in patients with glaucoma. Despite this finding, retinal damage and its relationship to CS was diffuse. In addition, SPARCS was shown to predict RNFLT. Further research is warranted to understand how CS can be used as a tool in the clinical setting.
NASA Astrophysics Data System (ADS)
Sevkat, Ercan
The goals of this study are to investigate the low velocity and ballistic impact response of thick-section hybrid fiber composites at room temperature. Plain-woven S2-Glass and IM7 Graphite fabrics are chosen as fiber materials reinforcing the SC-79 epoxy. Four different types of composites consisting of alternating layers of glass and graphite woven fabric sheets are considered. Tensile tests are conducted using 98 KN (22 kip) MTS testing machine equipped with environmental chamber. Low-velocity impact tests are conducted using an Instron-Dynatup 8250 impact test machine equipped with an environmental chamber. Ballistic impact tests are performed using helium pressured high-speed gas-gun. Tensile tests results were used to define the material behavior of the hybrid and non-hybrid composites in Finite Element modeling. The low velocity and ballistic impact tests showed that hybrid composites performance was somewhere between non-hybrid woven composites. Using woven glass fabrics as outer skin improved the impact performance of woven graphite composite. However hybrid composites are prone to delamination especially between dissimilar layers. The ballistic limit velocity V50 hybrid composites were higher that of woven graphite composite and lower than that of woven glass composite. Both destructive cross-sectional micrographs and nondestructive ultrasonic techniques are used to evaluate the damage created by impact. The Finite Element code LS-DYNA is chosen to perform numerical simulations of low velocity and ballistic impact on thick-section hybrid composites. The damage progression in these composites shows anisotropic nonlinearity. The material model to describe this behavior is not available in LS-DYNA material library. Initially, linear orthotropic material with damage (Chan-Chan Model) is employed to simulate some of the experimental results. Then, user-defined material subroutine is incorporated into LS-DYNA to simulate the nonlinear behavior. The experimentally obtained force-time histories, strain-time histories and damage patterns of impacted composites are compared with Finite element results. The results indicate that LS-DYNA could simulate the impact responses with sufficient accuracy once proper material models and boundary conditions are defined.
Corman, Gregory Scot
2003-04-15
A coating is applied to reinforcing fibers arranged into a tow by coaxially aligning the tow with an adjacent separation layer and winding or wrapping the tow and separation layer onto a support structure in an interleaved manner so that the separation layer separates a wrap of the tow from an adjacent wrap of the tow. A coating can then be uniformly applied to the reinforcing fibers without defects caused by fiber tow to fiber tow contact. The separation layer can be a carbon fiber veil.
International Instrumentation Symposium, 32nd, Seattle, WA, May 5-8, 1986, Proceedings
NASA Astrophysics Data System (ADS)
The conference presents papers on blast, shock, and vibration instrumentation; wind tunnel instrumentation and controls; electrooptic and fiber optic instrumentation; special test facilities; reentry vehicle testing; and nondestructive test and acoustic test instrumentation. Other topic include real time systems, flight test and avionics instrumentation, data aquisition and analysis systems, thermal measurements, and advances in measurement technology. Particular attention is given to an automated fringe counting laser interferometer for low frequency vibration measurements, dynamic pressure measurements in pneumatic lines, optically interfaced sensor system for aerospace applications, the picobalance for single microparticle measurements, ellipsometric film thickness, nanometer wear measurement by ultrathin surface layer activation, a rugged electronic scanner designed for turbine test, failure mechanism characterization of platinum alloy, and the thick film strain gage.
Tunable Engineered Skin Mechanics via Coaxial Electrospun Fiber Core Diameter
Blackstone, Britani Nicole; Drexler, Jason William
2014-01-01
Autologous engineered skin (ES) offers promise as a treatment for massive full thickness burns. Unfortunately, ES is orders of magnitude weaker than normal human skin causing it to be difficult to apply surgically and subject to damage by mechanical shear in the early phases of engraftment. In addition, no manufacturing strategy has been developed to tune ES biomechanics to approximate the native biomechanics at different anatomic locations. To enhance and tune ES biomechanics, a coaxial (CoA) electrospun scaffold platform was developed from polycaprolactone (PCL, core) and gelatin (shell). The ability of the coaxial fiber core diameter to control both scaffold and tissue mechanics was investigated along with the ability of the gelatin shell to facilitate cell adhesion and skin development compared to pure gelatin, pure PCL, and a gelatin-PCL blended fiber scaffold. CoA ES exhibited increased cellular adhesion and metabolism versus PCL alone or gelatin-PCL blend and promoted the development of well stratified skin with a dense dermal layer and a differentiated epidermal layer. Biomechanics of the scaffold and ES scaled linearly with core diameter suggesting that this scaffold platform could be utilized to tailor ES mechanics for their intended grafting site and reduce graft damage in vitro and in vivo. PMID:24712409
Green technologies in natural and synthetic surfaces use for dumps reclamation
NASA Astrophysics Data System (ADS)
Klimkina, Iryna; Fedotov, Viacheslav; Heilmeier, Hermann
2016-04-01
Last 50 years coal dumps reclamation in Ukraine was based on two- or three-layer models. These models use a fertile substratum underneath a black soil (chernozem) layer 0.5 m thick (Model 1) or 0.70-1 m thick (Model 2). Model 3 has 3 layers. The deepest layer is a substrate which is phytotoxic or unfavourable for crop growth (coal-bearing substrates with a high content of pyrite, saline substrates). The second layers acts as a protective shield and consist of loess (0.5 m). The third is the layer of fertile chernozem (0.3-0.8 m). However, due to the situation of a shortage of fertile soils, a lack of nutrient elements in the waste rock, and a moisture deficit with strong rock acidification, it is considered important to develop new non-traditional reclamation methods based on the geo-synthetic materials used in conjunction with sowing lawn grasses or grass seeds inside. The geogrids and biogeotextiles made from natural materials such as hemp, flax, jute, coconut and other plant biopolymer fibers are recommended for bioremediation. The biodegradable carcass of reclamation covering materials stabilises the slopes, effectively restraints the soil particles from leaching and blowing, and prevents wash-out of the plant seeds, as well as protecting them from being eaten by animals. The research object of the presented work was the coal dumps of sulfide rocks in Western Donbass (Ukraine). These rocks are characterized by low level of the maximum hygroscopic moisture (4.3%) and moisture content not available for plant growth (5-6%). Also the rock has an average level of salinity, mainly of the sulphate type. The main goal of the study was to justify the use of some non-traditional materials such as burlap (jute cloth), agricultural fibers (light non-woven material from polypropylene fiber of spun-bond type) and a padding of polyester in the capacity of a geosynthetic substrate as a basis for the mixed grass crop that enable a reduction in the bioremediation costs (in comparison with traditional methods of covering by fertile soil layer) and the arrangement of lawn roll. A mixture of grass crops was used that included three types of grass seeds which were sown in the condition of hydroponics with settled tap water in a floating poly-foam frame on the one- and two-layer (with grass seeds inside) substrates of the above-mentioned materials. The best results, in terms of seed germination, root and above-ground parts of the plants length, were obtained with a single layer of jute burlap on which practically all germinated seeds reached a high degree of seedlings mass and root productivity similar to indices of growth mixtures in greenhouses. As a mulch of organic ingredients a wide range of crop residues, namely wheat straw, corn stalks, sunflower stalks and husks, and others, can be used.
NASA Astrophysics Data System (ADS)
Khan, Z. M.; Adams, D. O.; Anas, S.
2016-01-01
As advanced composite materials having superior physical and mechanical properties are being developed, the optimization of their processing techniques is eagerly sought. One of the most common defects arising during processing of structural composites is layer waviness. The layer waviness is more pronounced in thick-section flat and cylindrical laminates, which are extensively used in large wind turbine blades, submersibles, and space platforms. The layer waviness undulates the entire layer of a multidirectional laminate in the throughthe-thickness direction, leading to a gross deterioration of its compressive strength. This research investigates the influence of multiple layer waviness in a double nest formation on the compression strength of a composite laminate. Different wave fractions of wavy 0° layers were fabricated in an IM/8551-7 carbon-epoxy composite laminate on a steel mold by using a single-step fabrication procedure. The test laminates were cured on a heated press according to the specific curing cycle of epoxy. Their static compression testing was performed using a NASA short block compression fixture on an MTS servohydraulic machine. The purpose of these tests was to determine the effects of multiple layer wave regions on the compression strength of the composite laminate. The experimental and analytical results obtained revealed that the reduction in the compression strength of composite laminate was constant after the fraction of the wavy 0° layers exceeded 35%. This analysis indicated that the percentage of the 0° wavy layer may be used to estimate the reduction in the compression strength of a double nested wave formation in a composite laminate.
Design and analysis of three-layer-core optical fiber
NASA Astrophysics Data System (ADS)
Zheng, Siwen; Liu, Yazhuo; Chang, Guangjian
2018-03-01
A three-layer-core single-mode large-mode-area fiber is investigated. The three-layer structure in the core, which is composed of a core-index layer, a cladding-index layer, and a depression-index layer, could achieve a large effective area Aeff while maintaining an ultralow bending loss without deteriorating cutoff behaviors. The single-mode large mode area of 100 to 330 μm2 could be achieved in the fiber. The effective area Aeff can be further enlarged by adjusting the layer parameters. Furthermore, the bending property could be improved in this three-layer-core structure. The bending loss could decrease by 2 to 4 orders of magnitude compared with the conventional step-index fiber with the same Aeff. These characteristics of three-layer-core fiber suggest that it can be used in large-mode-area wide-bandwidth high-capacity transmission or high-power optical fiber laser and amplifier in optical communications, which could be used for the basic physical layer structure of big data storage, reading, calculation, and transmission applications.
Design of Semi-composite Pressure Vessel using Fuzzy and FEM
NASA Astrophysics Data System (ADS)
Sabour, Mohammad H.; Foghani, Mohammad F.
2010-04-01
The present study attempts to present a new method to design a semi-composite pressure vessel (known as hoop-wrapped composite cylinder) using fuzzy decision making and finite element method. A metal-composite vessel was designed based on ISO criteria and then the weight of the vessel was optimized for various fibers of carbon, glass and Kevlar in the cylindrical vessel. Failure criteria of von-Mises and Hoffman were respectively employed for the steel liner and the composite reinforcement to characterize the yielding/ buckling of the cylindrical pressure vessel. The fuzzy decision maker was used to estimate the thickness of the steel liner and the number of composite layers. The ratio of stresses on the composite fibers and the working pressure as well as the ratio of stresses on the composite fibers and the burst (failure) pressure were assessed. ANSYS nonlinear finite element solver was used to analyze the residual stress in the steel liner induced due to an auto-frettage process. Result of analysis verified that carbon fibers are the most suitable reinforcement to increase strength of cylinder while the weight stayed appreciably low.
Hydrothermally Activated Graphene Fiber Fabrics for Textile Electrodes of Supercapacitors.
Li, Zheng; Huang, Tieqi; Gao, Weiwei; Xu, Zhen; Chang, Dan; Zhang, Chunxiao; Gao, Chao
2017-11-28
Carbon textiles are promising electrode materials for wearable energy storage devices owing to their conductive, flexible, and lightweight features. However, there still lacks a perfect choice for high-performance carbon textile electrodes with sufficient electrochemical activity. Graphene fiber fabrics (GFFs) are newly discovered carbon textiles, exhibiting various attractive properties, especially a large variability on the microstructure. Here we report the fabrication of hierarchical GFFs with significantly enlarged specific surface area using a hydrothermal activation strategy. By carefully optimize the activation process, the hydrothermally activated graphene fiber fabrics (HAGFFs) could achieve an areal capacitance of 1060 mF cm -2 in a very thin thickness (150 μm) and the capacitance is easily magnified by overlaying several layers of HAGFFs, even up to a record value of 7398 mF cm -2 . Meanwhile, a good rate capability and a long cycle life are also attained. As compared with other carbon textiles, including the commercial carbon fiber cloths, our HAGFFs present much better capacitive performance. Therefore, the mechanically stable, flexible, conductive, and highly active HAGFFs have provided an option for high-performance textile electrodes.
Development and characterization of orthotropic-birefringent materials
NASA Technical Reports Server (NTRS)
Daniel, I. M.; Koller, G. M.; Niiro, T.
1984-01-01
Materials were selected and fabrication procedures developed for orthotropic birefringent materials. An epoxy resin (Maraset 658/558 system) was selected as the matrix material. Fibers obtained from style 3733 glass cloth and type 1062 glass roving were used as reinforcement. Two different fabrication procedures were used. In the first one, layers of unidirectional fibers removed from the glass cloth were stacked, impregnated with resin, bagged and cured in the autoclave at an elevated temperature. In the second procedure, the glass roving was drywound over metal frames, impregnated with resin and cured at room temperature under pressure and vacuum in an autoclave. Unidirectional, angle-ply and quasi-isotropic laminates of two thicknesses and with embedded flaws were fabricated. The matrix and the unidirectional glass/epoxy material were fully characterized. The density, fiber volume ratio, mechanical, and optical properties were determined. The fiber volume ratio was over 0.50. Birefringent properties were in good agreement with predictions based on a stress proportioning concept and also, with one exception, with properties predicted by a finite element analysis. Previously announced in STAR as N81-26183
NASA Astrophysics Data System (ADS)
Liu, Dejun; Lian, Xiaokang; Mallik, Arun Kumar; Han, Wei; Wei, Fangfang; Yuan, Jinhui; Yu, Chongxiu; Farrell, Gerald; Semenova, Yuliya; Wu, Qiang
2017-04-01
A simple volatile organic compound (VOC) sensor based on a tapered small core singlemode fiber (SCSMF) structure is reported. The tapered SCSMF fiber structure with a waist diameter of 7.0 μm is fabricated using a customized microheater brushing technique. Silica based material containing immobilized Nile red was prepared by a sol-gel method and was used as a coating applied to the surface of the tapered fiber structure. Different coating thicknesses created by a 2-pass and 4-pass coating process are investigated. The experiments demonstrate that both sensors show a linear response at different gas concentrations to all three tested VOCs (methanol, ethanol and acetone). The sensor with a thicker coating shows better sensitivities but longer response and recovery times. The best measurement resolutions for the 4-pass coating sensor are estimated to be 2.3 ppm, 1.5 ppm and 3.1 ppm for methanol, ethanol and acetone, respectively. The fastest response and recovery time of 1 min and 5 min are demonstrated by the sensor in the case of methanol.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sweet, William J.; Oldham, Christopher J.; Parsons, Gregory N., E-mail: parsons@ncsu.edu
Flexible electronics and wearable technology represent a novel and growing market for next generation devices. In this work, the authors deposit conductive zinc oxide films by atomic layer deposition onto nylon-6 nonwoven fiber mats and spun-cast films, and quantify the impact that deposition temperature, coating thickness, and aluminum doping have on the conductivity of the coated substrates. The authors produce aluminum doped zinc oxide (AZO) coated fibers with conductivity of 230 S/cm, which is ∼6× more conductive than ZnO coated fibers. Furthermore, the authors demonstrate AZO coated fibers maintain 62% of their conductivity after being bent around a 3 mm radius cylinder.more » As an example application, the authors fabricate an “all-fiber” pressure sensor using AZO coated nylon-6 electrodes. The sensor signal scales exponentially under small applied force (<50 g/cm{sup 2}), yielding a ∼10{sup 6}× current change under 200 g/cm{sup 2}. This lightweight, flexible, and breathable touch/force sensor could function, for example, as an electronically active nonwoven for personal or engineered system analysis and diagnostics.« less
NASA Astrophysics Data System (ADS)
Meng, Xiuxia; Gong, Xun; Yin, Yimei; Yang, Naitao; Tan, Xiaoyao; Ma, Zi-Feng
2014-02-01
NiO-YSZ/porous YSZ (NiO-YSZ/p-YSZ) dual-layer hollow fibers have been fabricated by a co-spinning-sintering method, on which a dense YSZ films has been formed by a dip-coating and sintering process. A LSM-YSZ ink has been dip-coated on the dense YSZ films as cathode, while the Cu-CeO2 carbon-resistant catalyst has been impregnated in the p-YSZ layer to form double-anode supported micro tubular fuel cells (MT-SOFCs). The thickness of the Ni-YSZ layer, so called anode functional layer (AFL), is controlled from 74 μm to 13 μm by varying the spinning rates of the NiO-YSZ dopes. The maximum power density of an MT-SOFC, which is fabricated based on a thin co-spun AFL, reaches 566 mW cm-2 operated at 850 °C fed with dry methane, and is stably operated for 85 h without power declination.
Investigations of the mechanical properties of bi-layer and trilayer fiber reinforced composites
NASA Astrophysics Data System (ADS)
Jayakrishna, K.; Balasubramani, K.; Sultan, M. T. H.; Karthikeyan, S.
2016-10-01
Natural fibers are renewable raw materials with an environmental-friendly properties and they are recyclable. The mechanical properties of bi-layer and tri-layer thermoset polymer composites have been analyzed. The bi-layer composite consists of basalt and jute mats, while the tri-layer composite consists of basalt fiber, jute fiber and glass fiber mats. In both cases, the epoxy resin was used as the matrix and PTFE as a filler in the composites. The developed trilayer natural fiber composite can be used in various industrial applications such as automobile parts, construction and manufacturing. Furthermore, it also can be adopted in aircraft interior decoration and designed body parts. Flexural, impact, tensile, compression, shear and hardness tests, together with density measurement, were conducted to study the mechanical properties of both bi-layer and tri-layer composites. From the comparison, the tri-layer composite was found to perform in a better way in all tests.
Measuring joint cartilage thickness using reflectance spectroscopy non-invasively and in real-time
NASA Astrophysics Data System (ADS)
Canpolat, Murat; Denkceken, Tuba; Karagol, Cosar; Aydin, Ahmet T.
2011-03-01
Joint cartilage thickness has been estimated using spatially resolved steady-state reflectance spectroscopy noninvasively and in-real time. The system consists of a miniature UV-VIS spectrometer, a halogen tungsten light source, and an optical fiber probe with six 400 um diameter fibers. The first fiber was used to deliver the light to the cartilage and the other five were used to detect back-reflected diffused light. Distances from the detector fibers to the source fiber were 0.8 mm, 1.6 mm, 2.4 mm, 3.2 mm and 4 mm. Spectra of back-reflected diffused light were taken on 40 bovine patella cartilages. The samples were grouped into four; the first group was the control group with undamaged cartilages, in the 2nd, 3rd and 4th groups cartilage thickness was reduced approximately 25%, 50% and 100%, respectively. A correlation between cartilage thicknesses and hemoglobin absorption of light in the wavelength range of 500 nm- 600 nm for source-detector pairs was found. The proposed system with an optical fiber probe less than 4 mm in diameter has the potential for cartilage thickness assessment through an arthroscopy channel in real-time without damaging the cartilage.
Shi, Rui; Guo, Zhonglan; Wang, Feng; Li, Rong; Zhao, Lei; Lin, Rong
2018-02-01
To investigate the loss of retinal nerve fiber layer (RNFL) in type-2 diabetic patients with early-stage diabetic retinopathy (DR) and to identify potential risk factors accounting for these alterations. In this cross-sectional study, 158 type-2 diabetic patients were divided into three groups based on their DR status. RNFL thickness and other optic disc parameters were obtained by optical coherence tomography (OCT) and then compared among different groups. We investigated the potential association between RNFL loss and systemic risk factors for DR, including diabetes duration, body mass index (BMI), serum lipids, hemoglobin A1c (HbA1c) and albumin-creatinine ratio (ACR). One-way ANOVA was carried out to compare RNFL thickness among different groups, Pearson correlation and multivariate linear regression analysis were performed to determine potential risk factors related to RNFL thickness in these patients. There were significant differences in the average (F = 8.872, P = 0.003), superior (F = 8.769, P = 0.004), and inferior (F = 8.857, P = 0.003) RNFL thickness of both eyes among the groups, but no obvious difference in optic disc parameters was found. Diabetic duration, BMI, TG, High density lipoprotein cholesterol (HDL), HbA1c, and ACR were found negatively related to the RNFL thickness in both or single eye according to Pearson correlation analysis. After controlling for age, gender, and axis length (AL) in multivariate linear regression analysis, the diabetic duration was associated significantly with RNFL thickness of superior in both eye (right eye: p = 0.016, left eye: p = 0.024), BMI was related to the nasal quadrant of the right eye (p = 0.034), and TG was related to the inferior of the right eye (p = 0.037), HbA1c (p = 0.026) was associated significantly with the average RNFL thickness of the right eye. In addition, ACR was found negatively related to average (p = 0.042) and inferior quadrant (p = 0.014) of the left eye, respectively. RNFL loss might be the earliest structural change of retina in diabetic patients, and associated with diabetic duration, BMI, TG, HbA1c, and ACR. The conclusions of this study need to be proved by other well-matched and large-scale prospective clinical trials in the future, because the correlations discovered in our study were weak.
Elastic fiber-mediated enthesis in the human middle ear.
Kawase, Tetsuaki; Shibata, Shunichi; Katori, Yukio; Ohtsuka, Aiji; Murakami, Gen; Fujimiya, Mineko
2012-10-01
Adaptation to constant vibration (acoustic oscillation) is likely to confer a specific morphology at the bone-tendon and bone-ligament interfaces at the ear ossicles, which therefore represent an exciting target of enthesis research. We histologically examined (i) the bone attachments of the tensor tympani and stapedius muscles and (ii) the annular ligament of the incudostapedial joint obtained from seven elderly donated cadavers. Notably, both aldehyde-fuchsin and elastic-Masson staining demonstrated that the major fibrous component of the entheses was not collagen fibers but mature elastic fibers. The positive controls for elastic fiber staining were the arterial wall elastic laminae included in the temporal bone materials. The elastic fibers were inserted deeply into the type II collagen-poor fibrocartilage covering the ear ossicles. The muscle tendons were composed of an outer thin layer of collagen fibers and an inner thick core of elastic fibers near the malleus or stapes. In the unique elastic fiber-mediated entheses, hyaluronan, versican and fibronectin were expressed strongly along the elastic fibers. The hyaluronan seemed to act as a friction-reducing lubricant for the elastic fibers. Aggrecan was labeled strongly in a disk- or plica-like fibrous mass on the inner side of the elastic fiber-rich ligament, possibly due to compression stress from the ligament. Tenascin-c was not evident in the entheses. The elastic fiber-mediated entheses appeared resistant to tissue destruction in an environment exposed to constant vibration. The morphology was unlikely to be the result of age-related degeneration. © 2012 The Authors Journal of Anatomy © 2012 Anatomical Society.
Compromised Integrity of Central Visual Pathways in Patients With Macular Degeneration.
Malania, Maka; Konrad, Julia; Jägle, Herbert; Werner, John S; Greenlee, Mark W
2017-06-01
Macular degeneration (MD) affects the central retina and leads to gradual loss of foveal vision. Although, photoreceptors are primarily affected in MD, the retinal nerve fiber layer (RNFL) and central visual pathways may also be altered subsequent to photoreceptor degeneration. Here we investigate whether retinal damage caused by MD alters microstructural properties of visual pathways using diffusion-weighted magnetic resonance imaging. Six MD patients and six healthy control subjects participated in the study. Retinal images were obtained by spectral-domain optical coherence tomography (SD-OCT). Diffusion tensor images (DTI) and high-resolution T1-weighted structural images were collected for each subject. We used diffusion-based tensor modeling and probabilistic fiber tractography to identify the optic tract (OT) and optic radiations (OR), as well as nonvisual pathways (corticospinal tract and anterior fibers of corpus callosum). Fractional anisotropy (FA) and axial and radial diffusivity values (AD, RD) were calculated along the nonvisual and visual pathways. Measurement of RNFL thickness reveals that the temporal circumpapillary retinal nerve fiber layer was significantly thinner in eyes with macular degeneration than normal. While we did not find significant differences in diffusion properties in nonvisual pathways, patients showed significant changes in diffusion scalars (FA, RD, and AD) both in OT and OR. The results indicate that the RNFL and the white matter of the visual pathways are significantly altered in MD patients. Damage to the photoreceptors in MD leads to atrophy of the ganglion cell axons and to corresponding changes in microstructural properties of central visual pathways.
Hirasawa, Kazunori; Shoji, Nobuyuki
2017-01-01
To evaluate the influence of corneal power on circumpapillary retinal nerve fiber layer (cpRNFL) and optic nerve head (ONH) measurements by spectral-domain optical coherence tomography (SD-OCT). Twenty-five eyes of 25 healthy participants (mean age 23.6±3.6y) were imaged by SD-OCT using horizontal raster scans. Disposable soft contact lenses of different powers (from -11 to +5 diopters including 0 diopter) were worn to induce 2-diopter changes in corneal power. Differences in the cpRNFL and ONH measurements per diopter of change in corneal power were analyzed. As corneal power increased by 1 diopter, total and quadrant cpRNFL thicknesses, except for the nasal sector, decreased by --0.19 to -0.32 µm ( P <0.01). Furthermore, the disc, cup, and rim areas decreased by -0.017, -0.007, and -0.015 mm 2 , respectively ( P <0.001); the cup and rim volumes decreased by -0.0013 and -0.006 mm 3 , respectively ( P <0.01); and the vertical and horizontal disc diameters decreased by -0.006 and -0.007 mm, respectively ( P <0.001). For more precise OCT imaging, the ocular magnification should be corrected by considering both the axial length and corneal power. However, the effect of corneal power changes on cpRNFL thickness and ONH topography are small when compare with those of the axial length.
Effect Of Fluorine Doping On Radiation Hardness Of Graded Index Optical Fibers
NASA Astrophysics Data System (ADS)
Wei, T.; Singh, M. P.; Miniscalco, W. J.; Onorato, P. I. K.; Wall, J. A.
1987-01-01
We report an experimental and theoretical investigation of the effects of doping and processing on precursor defects in graded index multimode fibers. Fabrication parameters that significantly influence radiation sensitivity have been identified. In particular, we examined the role of fluorine doping in defect formation and its relationship to radiation sensitivity. The experimental effort included fiber fabrication and radiation-induced loss measurements on graded index, Ge-doped core fibers. Fluorine was added to the core and/or the cladding of test fibers. Two critical parameters, barrier layer thickness and core dopants, have been identified and correlate with induced loss. In addition, the reproducibility of both fiber fabrication and measurement with respect to induced loss has been tested and found to be excellent. Induced loss was found to be proportional to Ge concentration in the core; however, the trend with fluorine doping was less clear. The experimental results are consistent with molecular dynamics simulations which indicate the types and numbers of structural defects in the glasses. The simulations revealed significant differences in defect types and concentrations among glass corn-positions that included pure silica, Ge-doped silica, and Ge/F-codoped silica. Fluorine codoping decreases the number of germanium-related defects but increases the number of defects associated with silicon.
Black phosphorus saturable absorber for ultrashort pulse generation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sotor, J., E-mail: jaroslaw.sotor@pwr.edu.pl; Sobon, G.; Abramski, K. M.
Low-dimensional materials, due to their unique and versatile properties, are very interesting for numerous applications in electronics and optoelectronics. Recently rediscovered black phosphorus, with a graphite-like layered structure, can be effectively exfoliated up to the single atomic layer called phosphorene. Contrary to graphene, it possesses a direct band gap controllable by the number of stacked atomic layers. For those reasons, black phosphorus is now intensively investigated and can complement or replace graphene in various photonics and electronics applications. Here, we demonstrate that black phosphorus can serve as a broadband saturable absorber and can be used for ultrashort optical pulse generation.more » The mechanically exfoliated ∼300 nm thick layers of black phosphorus were transferred onto the fiber core, and under pulsed excitation at 1560 nm wavelength, its transmission increases by 4.6%. We have demonstrated that the saturable absorption of black phosphorus is polarization sensitive. The fabricated device was used to mode-lock an Er-doped fiber laser. The generated optical solitons with the 10.2 nm bandwidth and 272 fs duration were centered at 1550 nm. The obtained results unambiguously show that black phosphorus can be effectively used for ultrashort pulse generation with performances similar or even better than currently used graphene or carbon nanotubes. This application of black phosphorus proves its great potential to future practical use in photonics.« less
NASA Astrophysics Data System (ADS)
Emmanuel, A.; Raghavan, J.
2015-10-01
While LEO and GEO are used for most satellite missions, Highly Elliptical Orbits (HEOs) are also used for satellite missions covering Polar Regions of Earth. Satellites in HEO are exposed to a relatively harsher radiation environment than LEO and GEO. The mass of traditionally used aluminum radiation shield, required to attenuate the radiation to a level below a certain threshold that is safe for the satellite bus and payload, scales with the level of radiation. It has been shown (Emmanuel et al., 2014) that materials with low atomic number (Z) such as polyethylene (PE) can result in a lighter shield than aluminum (Al) in HEO. However, PE has to be reinforced with relatively high Z fibers such as graphite (G) to improve its mechanical properties. The effect of introduction of G and the resulting composite structure (that meets the requirements on mechanical properties, manufacturing and service) on the radiation shielding effectiveness of PE was studied through simulation using a layered PE-G composite. The Total Ionization Dose (TID), deposited in a silicon detector behind the composite shield, has been found to be function of layer volume fraction, layer thickness and stacking sequence of the PE and G layers. One composite configuration has resulted in a TID lower than that for PE, demonstrating the possibility of tailoring the mechanical properties of PE-based composite radiation shield with minimal negative impact on its radiation shielding effectiveness.
NASA Technical Reports Server (NTRS)
Hyer, M. W.; Charette, R. F.
1987-01-01
To increase the effectiveness and efficiency of fiber-reinforced materials, the use of fibers in a curvilinear rather than the traditional straightline format is explored. The capacity of a laminated square plate with a central circular hole loaded in tension is investigated. The orientation of the fibers is chosen so that the fibers in a particular layer are aligned with the principle stress directions in that layer. Finite elements and an iteration scheme are used to find the fiber orientation. A noninteracting maximum strain criterion is used to predict load capacity. The load capacities of several plates with different curvilinear fibers format are compared with the capacities of more conventional straightline format designs. It is found that the most practical curvilinear design sandwiches a group of fibers in a curvilinear format between a pair of +/-45 degree layers. This design has a 60% greater load capacity than a conventional quasi-isotropic design with the same number of layers. The +/-45 degree layers are necessary to prevent matrix cracking in the curvilinear layers due to stresses perpendicular to the fibers in those layers. Greater efficiencies are achievable with composite structures than now realized.
Flexible bactericidal graphene oxide-chitosan layers for stem cell proliferation
NASA Astrophysics Data System (ADS)
Mazaheri, M.; Akhavan, O.; Simchi, A.
2014-05-01
Graphene oxide (GO)-chitosan composite layers with stacked layer structures were synthesized using chemically exfoliated GO sheets (with lateral dimensions of ˜1 μm and thickness of ˜1 nm), and applied as antibacterial and flexible nanostructured templates for stem cell proliferation. By increasing the GO content from zero to 6 wt%, the strength and elastic modulus of the layers increased ˜80% and 45%, respectively. Similar to the chitosan layer, the GO-chitosan composite layers showed significant antibacterial activity (>77% inactivation after only 3 h) against Staphylococcus aureus bacteria. Surface density of the actin cytoskeleton fibers of human mesenchymal stem cells (hMSCs) cultured on the chitosan and GO(1.5 wt%)-chitosan composite layers was found nearly the same, while it significantly decreased by increasing the GO content to 3 and 6 wt%. Our results indicated that although a high concentration of GO in the chitosan layer (here, 6 wt%) could decelerate the proliferation of the hMSCs on the flexible layer, a low concentration of GO (i.e., 1.5 wt%) not only resulted in biocompatibility but also kept the mechanical flexibility of the self-sterilized layers for high proliferation of hMSCs.
NASA Astrophysics Data System (ADS)
Various papers on applied mathematics and mechanics are presented. Among the individual topics addressed are: dynamical systems with time-varying or unsteady structure, micromechanical modeling of creep rupture, forced vibrations of elastic sandwich plates with thick surface layers, postbuckling of a complete spherical shell under a line load, differential-geometric approach to the multibody system dynamics, stability of an oscillator with stochastic parametric excitation, identification strategies for crack-formation in rotors, identification of physical parameters of FEMs, impact model for elastic and partly plastic impacts on objects, varying delay and stability in dynamical systems. Also discussed are: parameter identification of a hybrid model for vibration analysis using the FEM, vibration behavior of a labyrinth seal with through-flow, similarities in the boundary layer of fiber composite materials, distortion parameter in shell theories, elastoplastic crack problem at finite strain, algorithm for computing effective stiffnesses of plates with periodic structure, plasticity of metal-matrix composites in a mixed stress-strain space formation, constitutive equations in directly formulated plate theories, microbuckling and homogenization for long fiber composites.
Zhou, Fanglei; Tien, Huynh Ngoc; Xu, Weiwei L; Chen, Jung-Tsai; Liu, Qiuli; Hicks, Ethan; Fathizadeh, Mahdi; Li, Shiguang; Yu, Miao
2017-12-13
Among the current CO 2 capture technologies, membrane gas separation has many inherent advantages over other conventional techniques. However, fabricating gas separation membranes with both high CO 2 permeance and high CO 2 /N 2 selectivity, especially under wet conditions, is a challenge. In this study, sub-20-nm thick, layered graphene oxide (GO)-based hollow fiber membranes with grafted, brush-like CO 2 -philic agent alternating between GO layers are prepared by a facile coating process for highly efficient CO 2 /N 2 separation under wet conditions. Piperazine, as an effective CO 2 -philic agent, is introduced as a carrier-brush into the GO nanochannels with chemical bonding. The membrane exhibits excellent separation performance under simulated flue gas conditions with CO 2 permeance of 1,020 GPU and CO 2 /N 2 selectivity as high as 680, demonstrating its potential for CO 2 capture from flue gas. We expect this GO-based membrane structure combined with the facile coating process to facilitate the development of ultrathin GO-based membranes for CO 2 capture.
Optical resonance analysis of reflected long period fiber gratings with metal film overlay
NASA Astrophysics Data System (ADS)
Zhang, Guiju; Cao, Bing; Wang, Chinua; Zhao, Minfu
2008-11-01
We present the experimental results of a novel single-ended reflecting surface plasma resonance (SPR) based long period fiber grating (LPFG) sensor. A long period fiber grating sensing device is properly designed and fabricated with a pulsed CO2 laser writing system. Different nm-thick thin metal films are deposited on the fiber cladding and the fiber end facet for the excitation of surface plasma waves (SPWs) and the reflection of the transmission spectrum of the LPFG with doubled interaction between metal-dielectric interfaces of the fiber to enhance the SPW of the all-fiber SPR-LPFG sensing system. Different thin metal films with different thicknesses are investigated. The effect of the excited SPW transmission along the fiber cladding-metal interface with silver and aluminum films is observed. It is found that different thicknesses of the metal overlay show different resonant behaviors in terms of resonance peak situation, bandwidth and energy loss. Within a certain range, thinner metal film shows narrower bandwidth and deeper peak loss.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheng, H., E-mail: harvey6117@gmail.com; Laboratory for Optical Physics and Engineering, Department of Electrical and Computer Engineering, University of Illinois, Urbana, Illinois 61801; Mironov, A. E.
2015-02-23
Direct coupling of the optical field in a ∼244 nm thick, CdSe/ZnS quantum dot film to an optical fiber has yielded lasing in the red (λ ∼ 644 nm) with a threshold pump energy density < 2.6 mJ cm{sup −2}. Comprising 28–31 layers of ∼8 nm diameter quantum dots deposited onto the exterior surface of a 125 μm diameter coreless silica fiber, this free-running oscillator produces 134 nJ in 3.6 ns FWHM pulses which correspond to 37 W of peak power from an estimated gain volume of ∼4.5 × 10{sup −7} cm{sup 3}. Lasing was confirmed by narrowing of the output optical radiation in both the spectral and temporal domains, and the lasermore » beam intensity profile approximates a top hat.« less
NASA Astrophysics Data System (ADS)
Sabau, Adrian S.; Greer, Clayton M.; Chen, Jian; Warren, Charles D.; Daniel, Claus
2016-07-01
The increasing use of carbon fiber-reinforced polymer matrix composites (CFPC) and aluminum alloys as lightweight materials in the automotive and aerospace industries demands enhanced surface preparation and control of surface morphology prior to joining. In this study, surfaces of both composite and aluminum were prepared for joining using an Nd:YAG laser in a two-beam interference setup, enabling the (1) structuring of the AL 5182 surface, (2) removal of the resin layer on top of carbon fibers, and (3) structuring of the carbon fibers. CFPC specimens of T700S carbon fiber, Prepreg—T83 epoxy, 5 ply thick, 0°/90° plaques were used. The effects of laser fluence, scanning speed, and number of shots-per-spot were investigated on the removal rate of the resin without an excessive damage of the fibers. Optical micrographs, 3D imaging, and scanning electron microscope imaging were used to study the effect of the laser processing on the surface morphology. It was found that an effective resin ablation and a low density of broken fibers for CFPC specimens was attained using laser fluences of 1-2 J/cm2 and number of 2-4 pulses per spot. A relatively large area of periodic line structures due to energy interference were formed on the aluminum surface at laser fluences of 12 J/cm2 and number of 4-6 pulses per spot.
Application of diffusion barriers to high modulus fibers
NASA Technical Reports Server (NTRS)
Veltri, R. D.; Douglas, F. C.; Paradis, E. L.; Galasso, F. S.
1977-01-01
Barrier layers were coated onto high-modulus fibers, and nickel and titanium layers were overcoated as simulated matrix materials. The objective was to coat the high-strength fibers with unreactive selected materials without degrading the fibers. The fibers were tungsten, niobium, and single-crystal sapphire, while the materials used as barrier coating layers were Al2O3, Y2O3, TiC, ZrC, WC with 14% Co, and HfO2. An ion-plating technique was used to coat the fibers. The fibers were subjected to high-temperature heat treatments to evaluate the effectiveness of the barrier layer in preventing fiber-metal interactions. Results indicate that Al2O3, Y2O3, and HfO2 can be used as barrier layers to minimize the nickel-tungsten interaction. Further investigation, including thermal cycling tests at 1090 C, revealed that HfO2 is probably the best of the three.
Skin aging as a mechanical phenomenon: The main weak links
Kruglikov, Ilja L.; Scherer, Philipp E.
2018-01-01
From a mechanical point of view, human skin appears as a layered composite containing the stiff thin cover layer presented by the stratum corneum, below which are the more compliant layers of viable epidermis and dermis and further below the much more compliant adjacent layer of subcutaneous white adipose tissue (sWAT). Upon exposure to a strain, such a multi-layer system demonstrates structural instabilities in its stiffer layers, which in its simplest form is the wrinkling. These instabilities appear hierarchically when the mechanical strain in the skin exceeds some critical values. Their appearance is mainly dependent on the mismatch in mechanical properties between adjacent skin layers or between the skin and sWAT, on the adhesive strength and thickness ratios between the layers, on their bending and tensile stiffness as well as on the value of the stress existing in single layers. Gradual reduction of elastic fibers in aging significantly reduces the skin’s ability to bend, prompting an up to 4-fold reduction of its stability against wrinkling, thereby explaining the role of these fibers in skin aging. While chronological and extrinsic aging differently modify these parameters, they lead to the same end result, reducing the critical strain required for the onset of instabilities. Comparing of mechanical properties of the skin presented as a bi-, tri- or tetra-layer structure demonstrates the particular importance of the papillary dermis in skin aging and provides the arguments to consider the undulations on the dermal-epidermal and dermal-sWAT interfaces as the result of mechanical bifurcation, leading to structural instabilities inside of the skin. According to this model, anti-aging strategies should focus not as much on the reinforcement of the dermis, but rather aim to treat the elastic mismatch between different adjacent layers in the skin and sWAT as well as the adhesion between these layers.
Behaviour of reinforced concrete slabs with steel fibers
NASA Astrophysics Data System (ADS)
Baarimah, A. O.; Syed Mohsin, S. M.
2017-11-01
This paper investigates the potential effect of steel fiber added into reinforced concrete slabs. Four-point bending test is conducted on six slabs to investigate the structural behaviour of the slabs by considering two different parameters; (i) thickness of slab (ii) volume fraction of steel fiber. The experimental work consists of six slabs, in which three slabs are designed in accordance to Eurocode 2 to fulfil shear capacity characteristic, whereas, the other three slabs are designed with 17% less thickness, intended to fail in shear. Both series of slabs are added with steel fiber with a volume fraction of Vf = 0%, Vf = 1% and Vf = 2% in order to study the effect and potential of fiber to compensate the loss in shear capacity. The slab with Vf = 0% steel fiber and no reduction in thickness is taken as the control slab. The experimental result suggests promising improvement of the load carrying capacity (up to 32%) and ductility (up to 87%) as well as delayed in crack propagation for the slabs with Vf = 2%. In addition, it is observed that addition of fibers compensates the reduction in the slab thickness as well as changes the failure mode of the slab from brittle to a more ductile manner.
NASA Astrophysics Data System (ADS)
Shakeri, Alireza; Ghasemian, Ali
2010-04-01
This study aims to investigate the moisture absorption of recycled newspaper fiber and recycled newspaper-glass fiber hybrid reinforced polypropylene composites to study their suitability in outdoor applications. In this work composite materials were made from E-glass fiber (G), recycled newspaper (NP) and polypropylene (PP), by using internal mixing and hot-pressing molding. Long-term water absorption (WA) and thickness swelling (TS) kinetics of the composites was investigated with water immersion. It was found that the WA and TS increase with NP content in composite and water immersion time before an equilibrium condition was reached. Composites made from the NP show comparable results as those made of the hybrid fiber. The results suggest that the water absorption and thickness swelling composite decrease with increasing glass fiber contents in hybrid fiber composite. It is interesting to find that the WA and TS can be reduced significantly with incorporation of a coupling agent (maleated polypropylene) in the composite formulation. Further studies were conducted to model the water diffusion and thickness swelling of the composites. Diffusion coefficients and swelling rate parameters in the models were obtained by fitting the model predictions with the experimental data.
Hollow fiber membranes and methods for forming same
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bhandari, Dhaval Ajit; McCloskey, Patrick Joseph; Howson, Paul Edward
2016-03-22
The invention provides improved hollow fiber membranes having at least two layers, and methods for forming the same. The methods include co-extruding a first composition, a second composition, and a third composition to form a dual layer hollow fiber membrane. The first composition includes a glassy polymer; the second composition includes a polysiloxane; and the third composition includes a bore fluid. The dual layer hollow fiber membranes include a first layer and a second layer, the first layer being a porous layer which includes the glassy polymer of the first composition, and the second layer being a polysiloxane layer whichmore » includes the polysiloxane of the second composition.« less
Automated classifiers for early detection and diagnosis of retinopathy in diabetic eyes.
Somfai, Gábor Márk; Tátrai, Erika; Laurik, Lenke; Varga, Boglárka; Ölvedy, Veronika; Jiang, Hong; Wang, Jianhua; Smiddy, William E; Somogyi, Anikó; DeBuc, Delia Cabrera
2014-04-12
Artificial neural networks (ANNs) have been used to classify eye diseases, such as diabetic retinopathy (DR) and glaucoma. DR is the leading cause of blindness in working-age adults in the developed world. The implementation of DR diagnostic routines could be feasibly improved by the integration of structural and optical property test measurements of the retinal structure that provide important and complementary information for reaching a diagnosis. In this study, we evaluate the capability of several structural and optical features (thickness, total reflectance and fractal dimension) of various intraretinal layers extracted from optical coherence tomography images to train a Bayesian ANN to discriminate between healthy and diabetic eyes with and with no mild retinopathy. When exploring the probability as to whether the subject's eye was healthy (diagnostic condition, Test 1), we found that the structural and optical property features of the outer plexiform layer (OPL) and the complex formed by the ganglion cell and inner plexiform layers (GCL + IPL) provided the highest probability (positive predictive value (PPV) of 91% and 89%, respectively) for the proportion of patients with positive test results (healthy condition) who were correctly diagnosed (Test 1). The true negative, TP and PPV values remained stable despite the different sizes of training data sets (Test 2). The sensitivity, specificity and PPV were greater or close to 0.70 for the retinal nerve fiber layer's features, photoreceptor outer segments and retinal pigment epithelium when 23 diabetic eyes with mild retinopathy were mixed with 38 diabetic eyes with no retinopathy (Test 3). A Bayesian ANN trained on structural and optical features from optical coherence tomography data can successfully discriminate between healthy and diabetic eyes with and with no retinopathy. The fractal dimension of the OPL and the GCL + IPL complex predicted by the Bayesian radial basis function network provides better diagnostic utility to classify diabetic eyes with mild retinopathy. Moreover, the thickness and fractal dimension parameters of the retinal nerve fiber layer, photoreceptor outer segments and retinal pigment epithelium show promise for the diagnostic classification between diabetic eyes with and with no mild retinopathy.
Endothelial glycocalyx: permeability barrier and mechanosensor.
Curry, F E; Adamson, R H
2012-04-01
Endothelial cells are covered with a polysaccharide rich layer more than 400 nm thick, mechanical properties of which limit access of circulating plasma components to endothelial cell membranes. The barrier properties of this endothelial surface layer are deduced from the rate of tracer penetration into the layer and the mechanics of red and white cell movement through capillary microvessels. This review compares the mechanosensor and permeability properties of an inner layer (100-150 nm, close to the endothelial membrane) characterized as a quasi-periodic structure which accounts for key aspects of transvascular exchange and vascular permeability with those of the whole endothelial surface layers. We conclude that many of the barrier properties of the whole surface layer are not representative of the primary fiber matrix forming the molecular filter determining transvascular exchange. The differences between the properties of the whole layer and the inner glycocalyx structures likely reflect dynamic aspects of the endothelial surface layer including tracer binding to specific components, synthesis and degradation of key components, activation of signaling pathways in the endothelial cells when components of the surface layer are lost or degraded, and the spatial distribution of adhesion proteins in microdomains of the endothelial cell membrane.
Nondestructive testing of CFRP plates by Lamb waves
NASA Astrophysics Data System (ADS)
Tsushima, Satoshi; Fukiage, Norio; Ono, Masao
1993-03-01
Nondestructive testing based on low frequency Lamb waves was used to analyze the thickness of plates, the delamination, the fiber contents, and the wave velocities in composite laminates. The thickness of plates was predicted and the delamination was detected using the relationship between the phase velocities of Lamb waves and the product of frequency and plate thickness. The fiber content was predicted from the stationary waves, and the wave velocity propagating at an angle to the fiber direction was calculated using the Young's modulus.
Masking of temperature-induced color changes in a thermo-sensitive fiber post.
Vichi, Alessandro; Schiavetti, Remo; Pacifici, Edoardo; Giovannetti, Agostino; Goracci, Cecilia; Ferrari, Marco
2012-04-01
To evaluate (1) the efficacy of the color changing technology featured by DT Light Illusion Post aimed at safely identifying the post in case of re-treatment, and (2) the efficacy of a resin composite layer to mask the post if color shift occurs due to cold food and beverages. Five "master disks" of 3 mm of thickness were prepared by embedding in a resin composite four thermo-sensitive posts and one translucent post (control) cut in bars. Disks of resin composite in 0.5/1.0/1.5 mm thickness were prepared as well. Digital images were taken of the master disks with and without the overlying of the resin composite disks, at 5 degrees C and at 35 degrees C temperature. By the use of Adobe Photoshop "layering function" and "multi-layer option", differences in color were calculated between the post-free and the post-containing areas. The differences between the resin color and post color were remarkably higher when the temperature was 5 degrees C, showing that the technology of color change of the post was effective. With resin disk overlaid, at 35 degrees C none of the differences in color were above the threshold for clinical acceptability. At 5 degrees C blue and black colored posts were visible when the overlaid resin thickness was 0.5 mm, while at 1.0 mm and 1.5 mm none of the posts were visible.
Pu, Juan; Komvopoulos, Kyriakos
2014-06-01
Bilayer fibrous membranes of poly(l-lactic acid) (PLLA) were fabricated by electrospinning, using a parallel-disk mandrel configuration that resulted in the sequential deposition of a layer with fibers aligned across the two parallel disks and a layer with randomly oriented fibers, both layers deposited in a single process step. Membrane structure and fiber alignment were characterized by scanning electron microscopy and two-dimensional fast Fourier transform. Because of the intricacies of the generated electric field, bilayer membranes exhibited higher porosity than single-layer membranes consisting of randomly oriented fibers fabricated with a solid-drum collector. However, despite their higher porosity, bilayer membranes demonstrated generally higher elastic modulus, yield strength and toughness than single-layer membranes with random fibers. Bilayer membrane deformation at relatively high strain rates comprised multiple abrupt microfracture events characterized by discontinuous fiber breakage. Bilayer membrane elongation yielded excessive necking of the layer with random fibers and remarkable fiber stretching (on the order of 400%) in the layer with fibers aligned in the stress direction. In addition, fibers in both layers exhibited multiple localized necking, attributed to the nonuniform distribution of crystalline phases in the fibrillar structure. The high membrane porosity, good mechanical properties, and good biocompatibility and biodegradability of PLLA (demonstrated in previous studies) make the present bilayer membranes good scaffold candidates for a wide range of tissue engineering applications. Copyright © 2014 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Tamrakar, Sandeep; An, Qi; Thostenson, Erik T; Rider, Andrew N; Haque, Bazle Z Gama; Gillespie, John W
2016-01-20
The electrophoretic deposition (EPD) method was used to deposit polyethylenimine (PEI) functionalized multiwall carbon nanotube (CNT) films onto the surface of individual S-2 glass fibers. By varying the processing parameters of EPD following Hamaker's equation, the thickness of the CNT film was controlled over a wide range from 200 nm to 2 μm. The films exhibited low electrical resistance, providing evidence of coating uniformity and consolidation. The effect of the CNT coating on fiber matrix interfacial properties was investigated through microdroplet experiments. Changes in interfacial properties due to application of CNT coatings onto the fiber surface with and without a CNT-modified matrix were studied. A glass fiber with a 2 μm thick CNT coating and the unmodified epoxy matrix showed the highest increase (58%) in interfacial shear strength (IFSS) compared to the baseline. The increase in the IFSS was proportional to CNT film thickness. Failure analysis of the microdroplet specimens indicated higher IFSS was related to fracture morphologies with higher levels of surface roughness. EPD enables the thickness of the CNT coating to be adjusted, facilitating control of fiber/matrix interfacial resistivity. The electrical sensitivity provides the opportunity to fabricate a new class of sizing with tailored interfacial properties and the ability to detect damage initiation.
Horn, Folkert K; Tornow, Ralf P; Jünemann, Anselm G; Laemmer, Robert; Kremers, Jan
2014-04-11
We compared the results of flicker-defined form (FDF) perimetry with standard automated perimetry (SAP) and retinal nerve fiber layer (RNFL) thickness measurements using spectral domain optical coherence tomography (OCT). A total of 64 healthy subjects, 45 ocular hypertensive patients, and 97 "early" open-angle glaucoma (OAG) patients participated in this study. Definition of glaucoma was based exclusively on glaucomatous optic disc appearance. All subjects underwent FDF perimetry, SAP, and peripapillary measurements of the RNFL thickness. The FDF perimetry and SAP were performed at identical test locations (G1 protocol). Exclusion criteria were subjects younger than 34 years, SAP mean defect (SAP MD) > 5 dB, eye diseases other than glaucoma, or nonreliable FDF measurements. The correlations between the perimetric data on one hand and RNFL thicknesses on the other hand were analyzed statistically. The age-corrected sensitivity values and the local results from the controls were used to determine FDF mean defect (FDF MD). The FDF perimetry and SAP showed high concordance in this cohort of experienced patients (MD values, R = -0.69, P < 0.001). Of a total of 42 OAG patients with abnormal SAP MD, 38 also displayed abnormal FDF MD. However, FDF MD was abnormal in 28 of 55 OAG patients with normal SAP MD. The FDF MD was significantly (R = -0.61, P < 0.001) correlated with RNFL thickness with a (nonsignificantly) larger correlation coefficient than conventional SAP MD (R = -0.48, P < 0.001). The FDF perimetry is able to uncover functional changes concurrent with the changes in RNFL thickness. The FDF perimetry may be an efficient functional test to detect early glaucomatous nerve atrophy. (ClinicalTrials.gov number, NCT00494923.).
Tatham, Andrew J.; Boer, Erwin R.; Rosen, Peter N.; Penna, Mauro Della; Meira-Freitas, Daniel; Weinreb, Robert N.; Zangwill, Linda M.; Medeiros, Felipe A.
2014-01-01
Purpose To examine the relationship between glaucomatous structural damage and ability to divide attention during simulated driving. Design Cross-sectional observational study. Methods Setting Hamilton Glaucoma Center, University of California San Diego. Patient Population 158 subjects from the Diagnostic Innovations in Glaucoma Study, including 82 with glaucoma and 76 similarly aged controls. Observation Procedure Ability to divide attention was investigated by measuring reaction times to peripheral stimuli (at low, medium or high contrast) while concomitantly performing a central driving task (car following or curve negotiation). All subjects had standard automated perimetry (SAP) and optical coherence tomography was used to measured retinal nerve fiber (RNFL) thickness. Cognitive ability was assessed using the Montreal Cognitive Assessment and subjects completed a driving history questionnaire. Main outcome measures Reaction times to the driving simulator divided attention task. Results The mean reaction times to the low contrast stimulus were 1.05 s and 0.64 s in glaucoma and controls respectively during curve negotiation (P <0.001), and 1.19 s and 0.77 s (P = 0.025) respectively during car following. There was a non-linear relationship between reaction times and RNFL thickness in the better eye. RNFL thickness remained significantly associated with reaction times even after adjusting for age, SAP mean deviation in the better eye, cognitive ability and central driving task performance. Conclusions Although worse SAP sensitivity was associated with worse ability to divide attention, RNFL thickness measurements provided additional information. Information from structural tests may improve our ability to determine which patients are likely to have problems performing daily activities, such as driving. PMID:25068641
Workability of glass reinforced concrete (GRC) with granite and silica sand aggregates
NASA Astrophysics Data System (ADS)
Moceikis, R.; Kičaitė, A.; Keturakis, E.
2017-10-01
Glass fiber reinforced concrete (GRC) opens the door for lightweight and complex shaped innovative construction, adding architectural value to buildings. With panel thickness down to 15 mm, considerable amount of total loads and materials per square meter of facade can be saved, if compared to conventionally used 80 mm thickness outer layer in insulated precast concrete wall elements. Even though GRC is used for over 50 years in such countries as Great Britain, USA and Japan, there are very few examples and little research done in Eastern Europe with this building material. European Commission propagates sustainable design as commitment to energy efficiency, environmental stewardship and conservation. For this reason, GRC plays important role in mowing toward these goals. In this paper, GRC premix recipes including fine granite and silica sands, reinforced with 13mm length alkali resistant glass fibers are investigated. Two CEM I 52,5R cements with different particle sizes were used and severe water dissociation noticed in one of concrete mixes. Cement particle size distribution determined with laser diffraction particle analyser Cilas 1090LD. To determine modulus of rupture (M.O.R.) and limit of proportionality (L.O.P), plates thickness 15 and 20 mm were produced and tested for flexural resistance according to 4-point bending scheme. Concrete workability tests were made according EN 1170-1.
Qu, Z; Kil, J; Xie, F; Garfinkel, A; Weiss, J N
2000-01-01
Scroll wave (vortex) breakup is hypothesized to underlie ventricular fibrillation, the leading cause of sudden cardiac death. We simulated scroll wave behaviors in a three-dimensional cardiac tissue model, using phase I of the Luo-Rudy (LR1) action potential model. The effects of action potential duration (APD) restitution, tissue thickness, filament twist, and fiber rotation were studied. We found that APD restitution is the major determinant of scroll wave behavior and that instabilities arising from APD restitution are the main determinants of scroll wave breakup in this cardiac model. We did not see a "thickness-induced instability" in the LR1 model, but a minimum thickness is required for scroll breakup in the presence of fiber rotation. The major effect of fiber rotation is to maintain twist in a scroll wave, promoting filament bending and thus scroll breakup. In addition, fiber rotation induces curvature in the scroll wave, which weakens conduction and further facilitates wave break. PMID:10827961
Optical fiber endface biosensor based on resonances in dielectric waveguide gratings
NASA Astrophysics Data System (ADS)
Wawro, Debra D.; Tibuleac, Sorin; Magnusson, Robert; Liu, Hanli
2000-05-01
A new fiber optic sensor integrating dielectric diffraction gratings and thin films on optical fiber endfaces is prosed for biomedical sensing applications. This device utilizes a resonant dielectric waveguide grating structure fabricated on an optical fiber endface to probe reactions occurring in a sensing layer deposited on its surface. The operation of this sensor is based upon a fundamental resonance effect that occurs in waveguide gratings. An incident broad- spectrum signal is guided within an optical fiber and is filtered to reflect or transmit a desired spectral band by the diffractive thin film structure on its endface. Slight changes in one or more parameters of the waveguide grating, such as refractive index or thickness, can result in a responsive shift of the reflected or transmitted spectral peak that can be detected with spectroscopic instruments. This new sensor concept combines improved sensitivity and accuracy with attractive features found separately in currently available fiber optic sensors, such as large dynamic range, small sensing proximity, real time operation, and remote sensing. Diffractive elements of this type consisting of a photoresist grating on a Si3N4 waveguide have been fabricated on multimode optical fiber endfaces with 100 micrometers cores. Preliminary experimental tests using a tunable Ti:sapphire laser indicate notches of 18 percent in the transmission spectrum of the fiber endface guided-mode resonance devices. A theoretical analysis of the device performance capabilities is presented and applied to evaluate the feasibility and potential advantages of this bioprobe.
Zhao, Peng-Fei; Zhou, Yue-Hua; Zhang, Jing; Wei, Wen-Bin
2017-09-20
Localized macular edema and retinal nerve fiber layer (RNFL) thinning have been reported shortly after laser in situ keratomileusis (LASIK) in adults. However, it is still unclear how LASIK affects the retina of children. This study aimed to investigate the macular retina and RNFL thickness in children with refractive amblyopia who underwent femtosecond laser-assisted LASIK (FS-LASIK). In this study, we included 56 eyes of 32 patients with refractive amblyopia who underwent FS-LASIK in our hospital from January 2012 to December 2016. Foveal (foveal center retinal, parafoveal retinal, and perifoveal), macular inner retinal (superior and inferior), and peripapillary RNFL thicknesses (superior, inferior, temporal, and nasal) were measured using Fourier-domain optical coherence tomography before surgery and 1 day, 3 days, and 1 week after surgery. We divided these patients into three groups based on their refractive error: High myopic group with 22 eyes (equivalent sphere, >6.00 D), mild myopic group with 19 eyes (equivalent sphere, 0-6.00 D), and hyperopic group with 15 eyes (equivalent sphere, >+0.50 D). We compared the macular retina and RNFL thickness before and after LASIK. A paired simple t-test was used for data analysis. One week after surgery, the visual acuity for all 56 eyes of the 32 patients reached their preoperative best-corrected vision. Visual acuity improved two lines or better for 31% of the patients. The residual refractive errors in 89% of the patients were within ±0.5 D. In the high myopic group, the foveal center retinal and parafoveal retinal thicknesses were thicker 1 day and 3 days after surgery than before surgery (t = 2.689, P = 0.012; t = 2.383, P = 0.018, respectively); no significant difference was found 1 week after surgery (P > 0.05). The foveal center retinal and parafoveal retinal thicknesses were greater 1 day after surgery than they were before surgery (P = 0.000 and P = 0.005, respectively) in the mild myopic and hyperopic groups. No significant difference was found 3 days or 1 week after surgery (P > 0.05). In all three groups, no significant difference was found in the macular inner retinal or peripapillary RNFL thickness 1 day, 3 days, or 1 week after surgery (P > 0.05). The foveal center retinal edema after FS-LASIK is mild and reversible in children, that mostly occurred in the high myopic group with no effect on the visual acuity, and is always relieved within 1 week.