Chiarelli, Marco; Achilli, Pietro; Guttadauro, Angelo; Vertemati, Giuseppe; Terragni, Sabina; De Simone, Matilde
2017-01-01
Chylothorax is a severe condition resulting from the accumulation of chyle into the pleural space. We report the treatment of postoperative chylothorax after resection of mediastinal ganglioneuroma in a 17-year-old boy. Since conservative measures were not effective, we performed direct ligation of lymphatic vessels and pleurodesis. At subsequent surgical re-exploration for persisting chylothorax, accurate inspection of pleural cavity revealed residual chyle leakage. Fibrin sealant patches (TachoSil®) were placed over the source of leak with complete resolution of chylous effusion. To our knowledge, this is the first report of postoperative chylothorax successfully treated by the use of a fibrin sealant patch. PMID:29221335
Spotnitz, William D.
2014-01-01
Background. Fibrin sealant became the first modern era material approved as a hemostat in the United States in 1998. It is the only agent presently approved as a hemostat, sealant, and adhesive by the Food and Drug Administration (FDA). The product is now supplied as patches in addition to the original liquid formulations. Both laboratory and clinical uses of fibrin sealant continue to grow. The new literature on this material also continues to proliferate rapidly (approximately 200 papers/year). Methods. An overview of current fibrin sealant products and their approved uses and a comprehensive PubMed based review of the recent literature (February 2012, through March 2013) on the laboratory and clinical use of fibrin sealant are provided. Product information is organized into sections based on a classification system for commercially available materials. Publications are presented in sections based on both laboratory research and clinical topics are listed in order of decreasing frequency. Results. Fibrin sealant remains useful hemostat, sealant, and adhesive. New formulations and applications continue to be developed. Conclusions. This agent remains clinically important with the recent introduction of new commercially available products. Fibrin sealant has multiple new uses that should result in further improvements in patient care. PMID:24729902
Matonick, John P; Hammond, Jeffrey
2014-12-01
First-generation single-component hemostats such as oxidized regenerated cellulose (ORC), fibrin, collagen, and gelatin have evolved into second and third generations of combination hemostats. This study compares two FDA approved products, EVARREST™, Fibrin Sealant Patch, a hemostat comprised of a matrix of nonwoven polyglactin 910 embedded in ORC coated with human fibrinogen and thrombin to TachoSil® medicated sponge, an equine collagen pad coated with human fibrinogen and thrombin. Swine were anticoagulated with heparin to 3X their baseline activated clotting time and a 15 mm long × 3 mm deep incision was made to create a consistent moderate bleeding pattern. Test material was then applied to the wound site and compressed manually for 3 min with just enough pressure to prevent continued bleeding. Hemostatic effectiveness was evaluated at 3 min and 10 min. At 3 min, the hemostasis success rate was 86% in the EVARREST™ group and 0% in the TachoSil® group, p < .0001. The overall success rate at 10 min was 100% with EVARREST™ and 4% with TachoSil®, p < .0001. Adhesive failure, in which the test material did not stick to the tissue, occurred in 96% of TachoSil® sites. In contrast, 100% of the EVARREST™ applications adhered to the test site. EVARREST™, Fibrin Sealant Patch demonstrated greater wound adhesion and more effective hemostasis than TachoSil®. Adhesive failure was the primary failure mode for TachoSil® in this model.
2017-05-15
experimentation are needed to determine the role of fibrin patches in acute traumatic hemorrhage control . 2.0 BACKGROUND Hemorrhage remains the most...Compare performance of CG to EVARREST in a porcine model of vascular trauma. Animals were separated into three groups : 1. Control : Arterial and...trauma. Animals were separated into three groups : 1. Control : Arterial and venous cannulation followed by laparotomy with liver injury and
2017-05-01
experimentation are needed to determine the role of fibrin patches in acute traumatic hemorrhage control . 2.0 BACKGROUND Hemorrhage remains the most...Compare performance of CG to EVARREST in a porcine model of vascular trauma. Animals were separated into three groups : 1. Control : Arterial and...trauma. Animals were separated into three groups : 1. Control : Arterial and venous cannulation followed by laparotomy with liver injury and
Fibrin sealants for the prevention of postoperative pancreatic fistula following pancreatic surgery.
Cheng, Yao; Ye, Mingxin; Xiong, Xianze; Peng, Su; Wu, Hong Mei; Cheng, Nansheng; Gong, Jianping
2016-02-15
Postoperative pancreatic fistula is one of the most frequent and potentially life-threatening complications following pancreatic resections. Fibrin sealants are introduced to reduce postoperative pancreatic fistula by some surgeons. However, the use of fibrin sealants during pancreatic surgery is controversial. To assess the safety, effectiveness, and potential adverse effects of fibrin sealants for the prevention of postoperative pancreatic fistula following pancreatic surgery. We searched The Cochrane Library (2015, Issue 7), MEDLINE (1946 to 26 August 2015), EMBASE (1980 to 26 August 2015), Science Citation Index Expanded (1900 to 26 August 2015), and Chinese Biomedical Literature Database (CBM) (1978 to 26 August 2015). We included all randomized controlled trials that compared fibrin sealant group (fibrin glue or fibrin sealant patch) versus control group (no fibrin sealant or placebo) in people undergoing pancreatic surgery. Two review authors independently identified the trials for inclusion, collected the data, and assessed the risk of bias. We performed the meta-analyses using Review Manager 5. We calculated the risk ratio (RR) for dichotomous outcomes (or a Peto odds ratio for very rare outcomes), and the mean difference (MD) for continuous outcomes with 95% confidence intervals (CI). We included nine trials involving 1095 participants who were randomized to the fibrin sealant group (N = 550) and the control group (N = 545) after pancreatic surgery. All of the trials were at high risk of bias. There was no evidence of differences in overall postoperative pancreatic fistula (fibrin sealant 29.6%; control 31.0%; RR 0.93, 95% CI 0.71 to 1.21; P = 0.58; nine studies; low-quality evidence), postoperative mortality (3.1% versus 2.1%; Peto OR 1.29, 95% CI 0.59 to 2.82; P = 0.53; eight studies; very low-quality evidence), overall postoperative morbidity (29.6% versus 28.9%; RR 1.04, 95% CI 0.82 to 1.32; P = 0.77; five studies), reoperation rate (8.7% versus 10.7%; RR 0.80, 95% CI 0.53 to 1.21; P = 0.29; five studies), or length of hospital stay (12.9 days versus 13.1 days; MD -0.73 days, 95% CI -2.20 to 0.74; P = 0.331; six studies) between the groups. The proportion of postoperative pancreatic fistula that was clinically significant was not mentioned in most trials. On inclusion of trials that clearly distinguished clinically significant fistulas, there was inadequate evidence to establish the effect of fibrin sealants on clinically significant postoperative pancreatic fistula (9.4% versus 13.4%; RR 0.72, 95% CI 0.42 to 1.21; P = 0.21; three studies). Quality of life and cost effectiveness were not reported in any of the trials. Based on the current available evidence, fibrin sealants do not seem to prevent postoperative pancreatic fistula in people undergoing pancreatic surgery.
Cha, Han Gyu; Shin, Ho Seong; Kang, Moon Seok; Nam, Seung Min
2012-01-01
Background The most common complication of latissimus dorsi myocutaneous flap in breast reconstruction is seroma formation in the back. Many clinical studies have shown that fibrin sealant reduces seroma formation. We investigated any statistically significant differences in postoperative drainage and seroma formation when utilizing the fibrin sealant on the site of the latissimus dorsi myocutaneous flap harvested for immediate breast reconstruction after skin-sparing partial mastectomy. Methods A total of 46 patients underwent immediate breast reconstruction utilizing a latissimus dorsi myocutaneous island flap. Of those, 23 patients underwent the procedure without fibrin sealant and the other 23 were administered the fibrin sealant. All flaps were elevated with manual dissection by the same surgeon and were analyzed to evaluate the potential benefits of the fibrin sealant. The correlation analysis and Mann-Whitney U test were used for analyzing the drainage volume according to age, weight of the breast specimen, and body mass index. Results Although not statistically significant, the cumulative drainage fluid volume was higher in the control group until postoperative day 2 (530.1 mL compared to 502.3 mL), but the fibrin sealant group showed more drainage beginning on postoperative day 3. The donor site comparisons showed the fibrin sealant group had more drainage beginning on postoperative day 3 and the drain was removed 1 day earlier in the control group. Conclusions The use of fibrin sealant resulted in no reduction of seroma formation. Because the benefits of the fibrin sealant are not clear, the use of fibrin sealant must be fully discussed with patients before its use as a part of informed consent. PMID:23094246
Effect of fibrin sealant in positioning and stabilizing microvascular pedicle: A comparative study.
Kim, Jeong Tae; Kim, Youn Hwan; Kim, Sang Wha
2017-07-01
Fibrin sealants have had applications in hemostasis, cohesion, and promotion of healing in plastic surgery. In this article, we review cases where fibrin sealant was used to stabilize microvascular pedicles and compared with previous free flaps performed without fibrin sealant. Between 2008 and 2010, 62 consecutive patients underwent free tissue transfer for reconstruction; this involved 33 latissimus dorsi perforator flaps, 14 thoracodorsal artery perforator flaps, 9 latissimus dorsi myocutaneous flaps, 3 lateral thoracic artery perforator flaps, and 3 transverse rectus abdominis myocutaneous flaps, used in head and neck reconstruction, lower limb reconstructions, breast reconstructions, and facial palsy reconstruction. Following microvascular anastomosis, the microvascular pedicles were placed in the optimal position, and fibrin sealant was used to fix and stabilize them. The complications, such as venous thrombosis, arterial thrombosis, hematoma, and vascular pedicle kinking, were compared with that of 672 previous free flaps without fibrin sealant for stabilizing microvascular pedicles. Among the 62 free tissue transfers using fibrin sealant, there was only one complication involving flap failure (1.6%), in this case due to venous thrombosis. Analysis of 672 free flaps performed without application of fibrin sealant revealed 24 complications (3.6%), due to 3 venous thrombosis, 1 arterial thrombosis, 4 vascular pedicel compression due to hematoma, and 16 pedicle kinking. However, the comparison of complications between the free flap using fibrin sealant and the free flap without fibrin sealant were not statistically significant (P = 0.65). Fibrin sealant can be used to prevent vascular kinking and to position anastomosed vessels after successful micro-anastomosis and allow the reconstructive surgeon to overcome challenging situations of vascular pedicle related complications © 2016 Wiley Periodicals, Inc. Microsurgery 37:406-409, 2017. © 2016 Wiley Periodicals, Inc.
Use of fibrin sealants in cardiovascular surgery: a systematic review.
Rousou, John A
2013-05-01
Fibrin sealants are used for hemostasis and tissue adherence. This systematic review summarizes published clinical data for fibrin sealant use in cardiovascular surgery. A literature search for the following terms was conducted using PubMed and EMBASE: (TISSEEL or Tissucol or Beriplast P or Evicel or Quixil or Crosseal or Reliseal or Fibringluraas or Bolheal or Tachosil or Vivostat or Vitagel or Artiss or "fibrin glue" or "fibrin sealant" or "fibrin tissue adhesive") and (cardiac or cardiovascular or vascular or heart or coronary or surgery). Case reports and series were excluded; although reports of controlled trials were preferred, uncontrolled trial data were also considered. Clinical trials and chart review analyses of fibrin sealants were identified and summarized. Although clinical trial data were available for other agents, the majority of published studies examined TISSEEL. Overall, TISSEEL and other fibrin sealants showed improvements over standard of care or control groups for a variety of predefined endpoints. Safety findings are also summarized. Data from these studies showed that fibrin sealants were well tolerated and provided effective hemostasis in a range of cardiac and aortic surgeries. © 2013 Wiley Periodicals, Inc.
Pandanaboyana, Sanjay; Bell, Richard; Shah, Nehal; Lodge, J Peter A; Hidalgo, Ernest; Toogood, Giles J; Prasad, K Raj
2017-06-01
There is paucity of data regarding the cost-effectiveness of fibrin sealants during liver surgery. This study aimed to assess the cost-effectiveness of fibrin sealants following right hemihepatectomy for colorectal liver metastases. A prospectively maintained database between 2004 and 2013 was reviewed to identify patients who underwent a right hemihepatectomy with and without fibrin sealant application. Perioperative and post-operative outcomes were analysed to assess its cost-effectiveness. One hundred and sixty-three right hemihepatectomies were performed, of which 79 were in the fibrin sealant treatment group and 84 were in the no sealant group. No difference was seen between fibrin sealant and no sealant with regard to bile leak (P = 0.366), intra-abdominal collections (P = 0.200) and overall post-operative complications (P = 0.480). Operating costs were significantly cheaper in the no sealant group (P = 0.010). There was no difference seen in median post-operative stay between fibrin sealant versus no treatment (8 versus 9 days, P = 0.327), median total bed cost (£3900 versus £4300, P = 0.400), mean transfusion cost per patient (P = 0.201) and overall cost (£6706.15 versus £6555.80, P = 0.792). Fibrin sealant application to cut surface during liver surgery confers no cost benefit and their routine use may not be recommended. © 2014 Royal Australasian College of Surgeons.
Fibrin Sealants in Dura Sealing: A Systematic Literature Review
2016-01-01
Background Fibrin sealants are widely used in neurosurgery to seal the suture line, provide watertight closure, and prevent cerebrospinal fluid leaks. The aim of this systematic review is to summarize the current efficacy and safety literature of fibrin sealants in dura sealing and the prevention/treatment of cerebrospinal fluid leaks. Methods A comprehensive electronic literature search was run in the following databases: Cochrane Database of Systematic Reviews, Cochrane Central Resister of Controlled Trials, clinicaltrials.gov, MEDLINE/PubMed, and EMBASE. Titles and abstracts of potential articles of interest were reviewed independently by 3 of the authors. Results A total of 1006 database records and additional records were identified. After screening for duplicates and relevance, a total of 78 articles were assessed by the investigators for eligibility. Thirty-eight were excluded and the full-text of 40 articles were included in the qualitative synthesis. Seven of these included only safety data and were included in the safety assessment. The remaining 33 articles included findings from 32 studies that enrolled a total of 2935 patients who were exposed to fibrin sealant. Among these 33 studies there were only 3 randomized controlled trials, with the remaining being prospective cohort analysis, case controlled studies, prospective or retrospective case series. One randomized controlled trial, with 89 patients exposed to fibrin sealant, found a greater rate of intraoperative watertight dura closure in the fibrin sealant group than the control group (92.1% versus 38.0%, p<0.001); however, post-operative cerebrospinal fluid leakage occurred in more fibrin sealant than control patients (6.7% versus 2.0%, p>0.05). Other clinical trials evaluated the effect of fibrin sealant in the postoperative prevention of cerebrospinal fluid leaks. These were generally lower level evidence studies (ie, not prospective, randomized, controlled trials) that were not designed or powered to demonstrate a significant advantage to fibrin sealant use. Two small case series studies evaluated the effect of fibrin sealants in persistent cerebrospinal fluid leak treatment, but did not establish firm efficacy conclusions. Specific adverse reports where fibrin sealants were used for dura sealing were limited, with only 8 cases reported in neurosurgical procedures since 1987 and most reporting only a speculative relationship/association with fibrin sealant exposure. Conclusions A major finding of this systematic literature review is that there is a paucity of randomized studies that have evaluated the effectiveness and safety of fibrin sealants in providing intraoperative watertight dura closure and post-operative cerebrospinal fluid leakage. Among the limited studies available, evidence from a single randomized, controlled trial indicates that fibrin sealants provide a higher rate of intraoperative watertight closure of the dura suture line than control, albeit with a higher rate of postoperative cerebrospinal fluid leakage. Evidence from non-randomized, controlled trials suggests that fibrin sealants may be effective in preventing cerebrospinal fluid leaks with an acceptable safety profile. There is a substantial need for randomized, controlled clinical trials or well-designed prospective observational trials where the conduct of a randomized trial is not feasible to fully assess the impact of fibrin sealant utilization on the rates of intraoperative dura closure, postoperative cerebrospinal leakage, and safety. PMID:27119993
Fibrin Sealants in Dura Sealing: A Systematic Literature Review.
Esposito, Felice; Angileri, Filippo Flavio; Kruse, Peter; Cavallo, Luigi Maria; Solari, Domenico; Esposito, Vincenzo; Tomasello, Francesco; Cappabianca, Paolo
2016-01-01
Fibrin sealants are widely used in neurosurgery to seal the suture line, provide watertight closure, and prevent cerebrospinal fluid leaks. The aim of this systematic review is to summarize the current efficacy and safety literature of fibrin sealants in dura sealing and the prevention/treatment of cerebrospinal fluid leaks. A comprehensive electronic literature search was run in the following databases: Cochrane Database of Systematic Reviews, Cochrane Central Resister of Controlled Trials, clinicaltrials.gov, MEDLINE/PubMed, and EMBASE. Titles and abstracts of potential articles of interest were reviewed independently by 3 of the authors. A total of 1006 database records and additional records were identified. After screening for duplicates and relevance, a total of 78 articles were assessed by the investigators for eligibility. Thirty-eight were excluded and the full-text of 40 articles were included in the qualitative synthesis. Seven of these included only safety data and were included in the safety assessment. The remaining 33 articles included findings from 32 studies that enrolled a total of 2935 patients who were exposed to fibrin sealant. Among these 33 studies there were only 3 randomized controlled trials, with the remaining being prospective cohort analysis, case controlled studies, prospective or retrospective case series. One randomized controlled trial, with 89 patients exposed to fibrin sealant, found a greater rate of intraoperative watertight dura closure in the fibrin sealant group than the control group (92.1% versus 38.0%, p<0.001); however, post-operative cerebrospinal fluid leakage occurred in more fibrin sealant than control patients (6.7% versus 2.0%, p>0.05). Other clinical trials evaluated the effect of fibrin sealant in the postoperative prevention of cerebrospinal fluid leaks. These were generally lower level evidence studies (ie, not prospective, randomized, controlled trials) that were not designed or powered to demonstrate a significant advantage to fibrin sealant use. Two small case series studies evaluated the effect of fibrin sealants in persistent cerebrospinal fluid leak treatment, but did not establish firm efficacy conclusions. Specific adverse reports where fibrin sealants were used for dura sealing were limited, with only 8 cases reported in neurosurgical procedures since 1987 and most reporting only a speculative relationship/association with fibrin sealant exposure. A major finding of this systematic literature review is that there is a paucity of randomized studies that have evaluated the effectiveness and safety of fibrin sealants in providing intraoperative watertight dura closure and post-operative cerebrospinal fluid leakage. Among the limited studies available, evidence from a single randomized, controlled trial indicates that fibrin sealants provide a higher rate of intraoperative watertight closure of the dura suture line than control, albeit with a higher rate of postoperative cerebrospinal fluid leakage. Evidence from non-randomized, controlled trials suggests that fibrin sealants may be effective in preventing cerebrospinal fluid leaks with an acceptable safety profile. There is a substantial need for randomized, controlled clinical trials or well-designed prospective observational trials where the conduct of a randomized trial is not feasible to fully assess the impact of fibrin sealant utilization on the rates of intraoperative dura closure, postoperative cerebrospinal leakage, and safety.
Superimposed Fungal Ulcer after Fibrin Glue Sealant in Infectious Corneal Ulcer
Byun, Yong-Soo
2011-01-01
A healthy 27-year-old woman with a corneal ulcer underwent fibrin gluing with a bandage contact lens twice, due to an impending perforation. The ulcer lesion slowly progressed, unresponsive to topical antibiotics and amphotericin B. We removed the gluing patch and performed a corneal or scraping or biopsy with multiple amniotic membrane grafts to seal the thinned or perforated cornea. Three days after the surgery, the corneal cultures grew Fusarium, as well as Enterococcus faecalis. Three weeks after surgery, the outermost layer of amniotic membranes, serving as a temporary patch, was removed. The anterior chamber was clear without cells. The signs of infection clinically and symptomatically cleared up four weeks later. Two months after surgery, the lesion became enhanced by amniotic membranes. The use of fibrin glue in infectious keratitis should be avoided, because it not only masks the underlying lesion, but it also interferes with drug penetration into the underlying lesion. PMID:22131784
Barbizan, Roberta; Castro, Mateus V.; Barraviera, Benedito; Ferreira, Rui S.; Oliveira, Alexandre L. R.
2014-01-01
The present work compared the local injection of mononuclear cells to the spinal cord lateral funiculus with the alternative approach of local delivery with fibrin sealant after ventral root avulsion (VRA) and reimplantation. For that, female adult Lewis rats were divided into the following groups: avulsion only, reimplantation with fibrin sealant; root repair with fibrin sealant associated with mononuclear cells; and repair with fibrin sealant and injected mononuclear cells. Cell therapy resulted in greater survival of spinal motoneurons up to four weeks post-surgery, especially when mononuclear cells were added to the fibrin glue. Injection of mononuclear cells to the lateral funiculus yield similar results to the reimplantation alone. Additionally, mononuclear cells added to the fibrin glue increased neurotrophic factor gene transcript levels in the spinal cord ventral horn. Regarding the motor recovery, evaluated by the functional peroneal index, as well as the paw print pressure, cell treated rats performed equally well as compared to reimplanted only animals, and significantly better than the avulsion only subjects. The results herein demonstrate that mononuclear cells therapy is neuroprotective by increasing levels of brain derived neurotrophic factor (BDNF) and glial derived neurotrophic factor (GDNF). Moreover, the use of fibrin sealant mononuclear cells delivery approach gave the best and more long lasting results. PMID:25157845
Systematic review and meta-analysis of fibrin sealants for patients undergoing pancreatic resection
Orci, Lorenzo A; Oldani, Graziano; Berney, Thierry; Andres, Axel; Mentha, Gilles; Morel, Philippe; Toso, Christian
2014-01-01
Introduction Post-operative pancreatic fistula (POPF) is a common complication after partial pancreatic resection, and is associated with increased rates of sepsis, mortality and costs. The role of fibrin sealants in decreasing the risk of POPF remains debatable. The aim of this study was to evaluate the literature regarding the effectiveness of fibrin sealants in pancreatic surgery. Methods A comprehensive database search was conducted. Only randomized controlled trials comparing fibrin sealants with standard care were included. A meta-analysis regarding POPF, intra-abdominal collections, post-operative haemorrhage, pancreatitis and wound infections was performed according to the recommendations of the Cochrane collaboration. Results Seven studies were included, accounting for 897 patients. Compared with controls, patients receiving fibrin sealants had a pooled odds ratio (OR) of developing a POPF of 0.83 [95% confidence interval (CI): 0.6–1.14], P = 0.245. There was a trend towards a reduction in post-operative haemorrhage (OR = 0.43 (95%CI: 0.18–1.0), P = 0.05) and intra-abdominal collections (OR = 0.52 (95%CI: 0.25–1.06), P = 0.073) in those patients receiving fibrin sealants. No difference was observed in terms of mortality, wound infections, re-interventions or hospital stay. Conclusion On the basis of these results, fibrin sealants cannot be recommended for routine clinical use in the setting of pancreatic resection. PMID:23461684
Prospective randomized controlled trial: fibrin sealant reduces split skin graft donor-site pain.
Healy, Ciaran; Greig, Aina V H; Murphy, Adrian D; Powell, Christopher; Pinder, Richard J; Saour, Samer; Abela, Christopher; Knight, William; Geh, Jenny L C
2013-07-01
Pain at split skin graft donor sites is common. Fibrin sealant has been demonstrated to reduce time to hemostasis at wound sites, and patients receiving this treatment were incidentally noted to report less pain. This study aimed to evaluate pain and incapacity in split skin graft donor sites treated with and without fibrin sealant. Fifty patients requiring thigh donor-site split skin grafts were prospectively randomized to receive either a self-adhesive fabric dressing alone or fibrin sealant plus the self-adhesive fabric dressing as primary donor-site dressings. External secondary dressings were the same. Patients were blinded with regard to treatment group. Using visual analogue scales (scored 0 to 5), patients rated their donor-site pain and incapacity for 14 days postoperatively. Secondary endpoints were length of hospital stay and duration of requirement for dressings. Forty patients were included in the study analysis and completed self-reported pain and incapacity scores. Twenty received the fibrin sealant plus self-adhesive fabric dressing and 20 received the fabric dressing only (controls). Patients using the fibrin sealant plus the dressing reported significantly less pain (mean score, 0.42 versus 1.60, p < 0.001) and significantly less incapacity (mean score, 0.48 versus 1.71, p < 0.001). Patients allocated to the fibrin sealant group recorded shorter lengths of stay and faster time to discontinuation of dressing, though statistical significance was not achieved. Patients whose split skin graft donor sites were dressed with fibrin sealant plus self-adhesive fabric dressing experienced significantly less pain and incapacity than patients with self-adhesive fabric dressings alone, allowing a more rapid return to normal activity. Therapeutic, II.
Effect of intracameral injection of fibrin tissue sealant on the rabbit anterior segment
Chew, Annabel C.Y.; Tan, Donald T.H.; Poh, Rebekah; HM, Htoon; Beuerman, Roger W.
2010-01-01
Purpose To investigate the effect of intracameral injection of fibrin tissue sealant on the anterior segment structures in a rabbit model. Methods One eye of 10 rabbits received an intracameral injection of fibrin tissue sealant with a thrombin concentration of 500 IU (TISSEEL), and the fellow eye received an intracameral injection of balanced salt solution as a control. The rabbits were followed up with serial slit-lamp examinations, photography, high resolution anterior segment optical coherence tomography scans with pachymetry measurement, and intraocular pressure (IOP) monitoring until complete dissolution of the fibrin sealant. Corneal endothelial cell viability was evaluated using live/dead cell assays. Apoptosis of the cornea and trabecular meshwork were evaluated using TUNEL assays. Ultra-structural examinations of the cornea and trabecular meshwork were performed using electron microscopy. Histology of the trabecular meshwork and iris were analyzed using light microscopy. Results The quantity of the intracameral fibrin sealant was shown to be significantly correlated with increased IOP and pachymetry post-operatively. Complete dissolution of the fibrin sealant occurred between 15 and 30 days. Live/dead cell assays showed no decrease in viability of the corneal endothelium, and TUNEL assays showed no increase in apoptosis of the corneal epithelium, stroma, endothelium, or trabecular meshwork in the eyes with the fibrin sealant. Light and electron microscopy of the anterior segment structures were unremarkable. Conclusion The intracameral use of fibrin glue was associated with a transient increase in IOP and pachymetry. However, there was no evidence of toxicity or structural damage to the corneal endothelium, trabecular meshwork, or iris. PMID:20596250
Sanjay, Pandanaboyana; Watt, David G; Wigmore, Stephen J
2013-04-01
Fibrin sealants are frequently used in liver surgery to achieve intraoperative haemostasis and reduce post-operative haemorrhage and bile leak. This meta-analysis aimed to review the haemostatic and biliostatic capacity of fibrin sealants in elective liver surgery. An electronic search was performed on the MEDLINE, Embase and PubMed databases using both subject headings and truncated word searches to identify all published articles that are related to this topic. Pooled risk ratios were calculated for categorical outcomes, and mean differences for secondary continuous outcomes, using the fixed-effects and random-effects models for meta-analysis. Ten randomised controlled trials encompassing 1,225 patients were analysed to achieve a summated outcome. Pooled data analysis showed the use of fibrin sealants resulted in reduced time to haemostasis (mean difference -3.45 min [-3.78, -3.13] (P < 0.00001)) and increased numbers of patients with complete haemostasis (risk ratio 1.56, 95 % confidence interval 1.04-2.34, p = 0.03) when compared to controls. The use of fibrin sealants did not influence perioperative blood transfusion requirements, bile leak rates, post-operative haemorrhage, intra-abdominal collections and overall morbidity and mortality compared with controls. There is no solid evidence that the routine use of fibrin sealants reduces the incidence of post-operative haemorrhage or bile leak compared with other treatments. The use of fibrin sealants may reduce the time to haemostasis, but this does not translate to improved perioperative outcomes.
Oshino, Satoru; Saitoh, Youichi; Yoshimine, Toshiki
2010-06-01
To examine the strength and tolerance of the fibrin glue sealant in a situation of extended transsphenoidal surgery. The withstand pressure of fibrin glue sealant was measured using a simple sellar reconstruction model. A 15-mm diameter hole at the bottom of a 51-cm high cylinder was covered with a Gore-Tex (Gore-Tex, Tokyo, Japan) sheet. A small plate was placed on the center for a brief fixation, and 3 mL of fibrin glue was applied over the entire bottom. Then water was gradually filled in five cylinders, and the water level at leakage was measured as withstand pressures at 10 minutes and 24 hours after sealant application. The stability of the sealant under pressures of 20 and 30 cm H(2)O for 12 hours was also examined. The median initial withstand pressure at 10 minutes was 32 cm H(2)O (n = 5), and was significantly increased to 47.5 cm H(2)O after 24 hours (n = 4). In four of five cylinders, fibrin glue sealants were stable against a pressure of 20 cm H(2)O for 12 hours and 30 cm H(2)O for the next 12 hours. The withstand pressure of simple fibrin glue sealant without other biological reactions could be estimated to be more than 20 cm H(2)O after application, and increased to more than 40 cm H(2)O after 24 hours. These data are practical for neurosurgeons to comprehend the strength and limit of fibrin glue sealant and suggests the importance to control the intracranial pressure to less than 20 cm H(2)O, especially for the first 12 to 24 hours. Copyright © 2010 Elsevier Inc. All rights reserved.
Han, Hyun Ho; Jun, Daiwon; Moon, Suk-Ho; Kang, In Sook; Kim, Min Cheol
2016-01-01
For skin defects caused by full-thickness burns, trauma, or tumor tissue excision, skin grafting is one of the most convenient and useful treatment methods. In this situation, graft fixation is important in skin grafting. This study was performed to compare the effectiveness of skin graft fixation between high-concentration fibrin sealant and sutures. There have been numerous studies using fibrin sealant for graft fixation, but they utilized slow-clotting fibrin sealant containing less than 10 IU/mL thrombin. Twenty-five patients underwent split-thickness skin grafting using fast-clotting fibrin sealant containing 400 IU/mL thrombin, while 30 patients underwent grafting using sutures. Rates of hematoma/seroma formation, graft dislocation, graft necrosis, and graft take were investigated postoperatively. The graft surface area was calculated using Image J software (National Institutes of Health, Bethesda, MD, USA). After 5 days, rates of hematoma/seroma formation and graft dislocation were 7.84 and 1.29% in group I, and 9.55 and 1.45% in group II, respectively. After 30 days, rates of graft necrosis and graft take were 1.86 and 98.14% in group I, and 4.65 and 95.35% in group II. Undiluted fibrin sealant showed significantly superior results for all rates ( p < 0.05) except graft dislocation. When high-concentration fast-clotting fibrin sealant was applied to skin grafts without dilution, no difficulty was experienced during surgery. Sealant showed superior results compared with sutures and had an excellent graft take rate. II.
Eriksen, J R; Bisgaard, T; Assaadzadeh, S; Jorgensen, L N; Rosenberg, J
2013-08-01
Fibrin sealant for mesh fixation has significant positive effects on early outcome after laparoscopic ventral hernia repair (LVHR) compared with titanium tacks. Whether fibrin sealant fixation also results in better long-term outcome is unknown. We performed a randomized controlled trial including patients with umbilical hernia defects from 1.5 to 5 cm at three Danish hernia centres. We used a 12 cm circular mesh. Participants were randomized to fibrin sealant or titanium tack fixation. Patients were seen in the outpatient clinic at 1 and 12 months follow-up. Forty patients were included of whom 34 were available for intention to treat analysis after 1 year. There were no significant differences in pain, discomfort, fatigue, satisfaction or quality of life between the two groups at the 1-year follow-up. Five patients (26 %) in the fibrin sealant group and one (6 %) in the tack group were diagnosed with a recurrence at the 1-year follow-up (p = 0.182) (overall recurrence rate 17 %). Hernia defects in patients with recurrence were significantly larger than in those without recurrence (median 4.0 vs. 2.8 cm, p = 0.009). Patients with larger hernia defects and fibrin sealant mesh fixation had higher recurrence rates than expected, although the study was not powered for assessment of recurrence. There was no significant difference between groups in any parameters after the 1-year follow-up. The beneficial effects of mesh fixation with fibrin sealant on early outcome warrant further studies on optimization of the surgical technique to prevent recurrence.
Tensile strength of biological fibrin sealants: a comparative study.
Lacaze, Laurence; Le Dem, Nicolas; Bubenheim, Michael; Tsilividis, Basile; Mezghani, Julien; Schwartz, Lilian; Francois, Arnaud; Ertaud, Jean Yves; Bagot d'Arc, Maurice; Scotté, Michel
2012-08-01
Fibrin sealants are commonly used in liver surgery, although their effectiveness in routine clinical practice remains controversial. Individual sealant characteristics are based on hemostatic effects and adhesion properties that can be experimentally measured using the 'rat skin test' or the 'pig skin test'. This study used a more relevant and realistic experimental canine model to compare the differences in the adhesive properties of four fibrin sealants in hepatectomy: Tisseel/Tissucol, Tachosil, Quixil, and Beriplast. A partial hepatectomy was performed in beagle dogs under general anesthesia to obtain liver cross-sections. Fibrin sealants were allocated to dog livers using a Youden square design. The tensile strength measurement was performed using a traction system to measure the rupture stress point of a small wooden cylinder bonded to the liver cross-section. Significantly greater adhesion properties were observed with Tisseel/Tissucol compared with Quixil or Beriplast (P = 0.002 and 0.001, respectively). Similarly, Tachosil demonstrated significantly greater adhesive properties compared with Beriplast (P = 0.009) or Quixil (P = 0.014). No significant differences were observed between Tisseel/Tissucol and Tachosil or between Beriplast and Quixil. The results of this comparative study demonstrate that different fibrin sealants exhibit different adhesive properties. Tisseel/Tissucol and Tachosil provided greatest adhesion to liver cross-section in our canine model of hepatectomy. These results may enable the optimal choice of fibrin sealants for this procedure in clinical practice. Copyright © 2012 Elsevier Inc. All rights reserved.
Collagen sealant patch to reduce lymphatic drainage after lymph node dissection.
Di Monta, Gianluca; Caracò, Corrado; Crispo, Anna; Marone, Ugo; Mozzillo, Nicola
2012-12-19
Seroma formation is a frequent complication following radical lymph node dissection (RLND) in patients with metastatic melanoma. Several strategies have been used to prevent fluid accumulation and thereby reduce the duration of postoperative drainage, including fibrin sealants. This was a prospective, single-center study in which consecutive patients undergoing surgical treatment of stage III metastatic melanoma by axillary or ilio-inguinal RLND were randomized to receive standard treatment plus fibrinogen/thrombin-coated collagen sealant patch (CSP) or standard treatment alone. The primary endpoint of the study was postoperative duration of drainage. A total of 70 patients underwent axillary (n = 47) or ilio-inguinal (n = 23) RLND and received CSP plus standard treatment (n = 37) or standard treatment alone (n = 33). Mean duration of drainage was significantly reduced in the CSP group compared with standard treatment (ITT analysis: 20.1 ± 5.1 versus 23.3 ± 5.1 days; p = 0.010). The percentage of patients drainage-free on day 21 was significantly higher in the CSP group compared with the standard treatment group (86% versus 67%; p = 0.049). Use of the tissue sealant resulted in a significant reduction in duration of drainage. Further studies are warranted to confirm these results in different and selected types of lymphadenectomy.
Collagen sealant patch to reduce lymphatic drainage after lymph node dissection
2012-01-01
Background Seroma formation is a frequent complication following radical lymph node dissection (RLND) in patients with metastatic melanoma. Several strategies have been used to prevent fluid accumulation and thereby reduce the duration of postoperative drainage, including fibrin sealants. Methods This was a prospective, single-center study in which consecutive patients undergoing surgical treatment of stage III metastatic melanoma by axillary or ilio-inguinal RLND were randomized to receive standard treatment plus fibrinogen/thrombin-coated collagen sealant patch (CSP) or standard treatment alone. The primary endpoint of the study was postoperative duration of drainage. Results A total of 70 patients underwent axillary (n = 47) or ilio-inguinal (n = 23) RLND and received CSP plus standard treatment (n = 37) or standard treatment alone (n = 33). Mean duration of drainage was significantly reduced in the CSP group compared with standard treatment (ITT analysis: 20.1 ± 5.1 versus 23.3 ± 5.1 days; p = 0.010). The percentage of patients drainage-free on day 21 was significantly higher in the CSP group compared with the standard treatment group (86% versus 67%; p = 0.049). Conclusions Use of the tissue sealant resulted in a significant reduction in duration of drainage. Further studies are warranted to confirm these results in different and selected types of lymphadenectomy. PMID:23253298
Fibrin sealant use for minimising peri-operative allogeneic blood transfusion
Carless, Paul A; Henry, David A; Anthony, Danielle M
2014-01-01
Background Fibrin sealants (also referred to as biological glue or fibrin tissue adhesives) have gained increasing popularity as interventions to improve peri-operative (intra- and post-operative) haemostasis and diminish the need for allogeneic red cell transfusion (blood from an unrelated donor). Objectives To examine the efficacy of fibrin sealants in reducing peri-operative blood loss and allogeneic red blood cell (RBC) transfusion. Search methods We identified studies by searching CENTRAL (The Cochrane Library 2007, Issue 3), MEDLINE (1950 to 2008), EMBASE (1980 to 2008), manufacturer web sites (to March 2008), and bibliographies of relevant published articles. Selection criteria Controlled trials in which adult patients scheduled for elective surgery were randomised to fibrin sealant treatment or to a control group which did not receive fibrin sealant treatment. Trials were eligible if they reported data on the number of patients exposed to allogeneic red cell transfusion, the volume of blood transfused, or blood loss (assessed objectively). Data collection and analysis The primary outcomes measured were the: number of patients exposed to allogeneic red cells, amount of blood transfused, and blood loss. Other outcomes measured were: re-operation due to bleeding, infection, mortality, thrombotic events, and length of hospital stay. Treatment effects were pooled using a random-effects model. Main results Eighteen trials that included a total of 1406 patients reported data on peri-operative exposure to allogeneic RBC transfusion. Fibrin sealant treatment, on average, reduced the rate of exposure to allogeneic RBC transfusion by a relative 37% (relative risk (RR) 0.63, 95% confidence interval (CI) 0.45 to 0.88) and 7% in absolute terms (95% CI 2% to 13%). Fourteen trials, including a total of 853 patients, provided data for post-operative blood loss. In aggregate, fibrin sealant treatment reduced blood loss on average by around 161 ml per patient (95% CI 98.25 to 224.53 ml). In the context of orthopaedic surgery, fibrin sealant treatment reduced post-operative blood loss on average by around 223 ml per patient (95% CI 119.85 to 325.18 ml) and reduced the risk of exposure to allogeneic RBC transfusion by 32% (RR 0.68, 95% CI 0.51 to 0.89). Fibrin sealant treatment was not associated with an increased risk of wound infection (RR 0.61, 95% CI 0.24 to 1.58), any infection (RR 0.93, 95% CI 0.44 to 1.94), haematoma formation (RR 0.46, 95% CI 0.18 to 1.18), or death (RR 0.85, 95% CI 0.38 to 1.89). Hospital length of stay was not reduced in patients treated with fibrin sealant (weighted mean difference (WMD) −0.21 days, 95% CI −0.42 to 0.01 days). Authors’ conclusions Overall, the results suggest that fibrin sealants are efficacious in reducing both post-operative blood loss and peri-operative exposure to allogeneic RBC transfusion. Although treatment-effect heterogeneity was observed for these primary efficacy outcomes, heterogeneity was generally in terms of the size of effect rather than the direction of effect. Fibrin sealants appeared to demonstrate their greatest beneficial effects in the context of orthopaedic surgery, where blood loss is often substantial. Trials not involving orthopaedic surgery generally showed a trend toward decreased post-operative blood loss but the observed reductions were not clinically significant. The majority of trials included in this review were small, which raises concerns about the potential effects of publication bias. Funnel plot assessment indicates that there is some evidence of publication bias in the form of a missing population of small negative trials. We believe that large, methodologically rigorous, randomised controlled trials of fibrin sealants are needed. PMID:12804501
Xu, Fei-Fan; Wang, Yue-Chun; Sun, Stella; Ho, Amy S W; Lee, Derek; Kiang, Karrie M Y; Zhang, Xiao-Qin; Lui, Wai-Man; Liu, Bai-Yun; Wu, Wu-Tian; Leung, Gilberto K K
2015-10-01
RADA16-I is a synthetic type I self-assembling peptide nanofiber scaffold (SAPNS) which may serve as a novel biocompatible hemostatic agent. Its application in neurosurgical hemostasis, however, has not been explored. Although RADA16-I is nontoxic and nonimmunogenic, its intrinsic acidity may potentially provoke inflammation in the surgically injured brain. We conducted an animal study to compare RADA16-I with fibrin sealant, a commonly used agent, with the hypothesis that the former would be a comparable alternative. Using a standardized surgical brain injury model, 30 Sprague-Dawley rats were randomized into three treatment groups: RADA16-I, fibrin sealant or gelatin sponge (control). Animals were sacrificed on day 3 and 42. Astrocytic and microglial infiltrations within the cerebral parenchyma adjacent to the operative site were significantly lower in the RADA16-I and fibrin sealant groups than control. RADA16-I did not cause more cellular inflammatory response despite its acidity when compared with fibrin sealant. Immunohistochemical studies showed infiltration by astrocytes and microglia into the fibrin sealant and RADA16-I grafts, suggesting their potential uses as tissue scaffolds. RADA16-I is a promising candidate for further translational and clinical studies that focus on its applications as a safe and effective hemostat, proregenerative nanofiber scaffold as well as drug and cell carrier. © 2015 Wiley Periodicals, Inc.
A new fibrin sealant as a three-dimensional scaffold candidate for mesenchymal stem cells
2014-01-01
Introduction The optimization of an organic scaffold for specific types of applications and cells is vital to successful tissue engineering. In this study, we investigated the effects of a new fibrin sealant derived from snake venom as a scaffold for mesenchymal stem cells, to demonstrate the ability of cells to affect and detect the biological microenvironment. Methods The characterization of CD34, CD44 and CD90 expression on mesenchymal stem cells was performed by flow cytometry. In vitro growth and cell viability were evaluated by light and electron microscopy. Differentiation into osteogenic, adipogenic and chondrogenic lineages was induced. Results The fibrin sealant did not affect cell adhesion, proliferation or differentiation and allowed the adherence and growth of mesenchymal stem cells on its surface. Hoechst 33342 and propidium iodide staining demonstrated the viability of mesenchymal stem cells in contact with the fibrin sealant and the ability of the biomaterial to maintain cell survival. Conclusions The new fibrin sealant is a three-dimensional scaffolding candidate that is capable of maintaining cell survival without interfering with differentiation, and might also be useful in drug delivery. Fibrin sealant has a low production cost, does not transmit infectious diseases from human blood and has properties of a suitable scaffold for stem cells because it permits the preparation of differentiated scaffolds that are suitable for every need. PMID:24916098
Biomechanical analyses of mesh fixation in TAPP and TEP hernia repair.
Schwab, R; Schumacher, O; Junge, K; Binnebösel, M; Klinge, U; Becker, H P; Schumpelick, V
2008-03-01
Reliable laparoscopic fixation of meshes prior to their fibrous incorporation is intended to minimize recurrences following transabdominal preperitoneal hernia repair (TAPP) and totally extraperitoneal repair (TEP) repair of inguinal hernias. However, suture-, tack- and staple-based fixation systems are associated with postoperative chronic inguinal pain. Initial fixation with fibrin sealant offers an atraumatic alternative, but there is little data demonstrating directly whether fibrin-based mesh adhesion provides adequate biomechanical stability for repair of inguinal hernia by TAPP and TEP. Using a newly developed, standardized simulation model for abdominal wall hernias, sublay repairs were performed with six different types of commercially available hernia mesh. The biomechanical stability achieved, and the protection afforded by the mesh-hernia overlap, were compared for three different techniques: nonfixation, point-by-point suture fixation, and fibrin sealant fixation. Mesh dislocation from the repaired hernia defect was consistently seen with nonfixation. This was reliably prevented with all six mesh types when fixed using either sutures or fibrin sealant. The highest stress resistance across the whole abdominal wall was found following superficial fixation with fibrin sealant across the mesh types. There was a highly statistically significant improvement in fixation stability with fibrin sealant versus fixation using eight single sutures (p = 0.008), as assessed by the range of achievable peak pressure stress up to 200 mmHg. To ensure long-term freedom from recurrence, intraoperative mesh-hernia overlap must be retained. This can be achieved with fibrin sealant up to the incorporation of the mesh - without trauma and with biomechanical stability.
Kaufman, Herbert E; Insler, Michael S; Ibrahim-Elzembely, Hosan A; Kaufman, Stephen C
2003-11-01
To determine whether a fibrin adhesive can facilitate the performance of sutureless lamellar keratoplasty and attachment of amnion to bare sclera. Prospective, noncomparative case series. Six patients, 5 of whom underwent lamellar keratoplasty and 1 who received an amniotic patch of the sclera and cornea. Institutional review board approval was not required for these therapeutic treatments. In 5 patients, the epithelium was removed from the corneal surface, a free cap, 200- micro m thick, was cut with a microkeratome, and a human fibrin tissue adhesive (Tisseel VH Fibrin Sealant; Baxter Healthcare Corporation, Glendale, CA) was applied to the cut surface of the corneal stroma. A 200- micro m thick, microkeratome-cut lamellar graft was placed in the stromal bed without sutures, and a bandage soft contact lens was applied. The lens was left in place for 1 week and then removed. In 1 patient, the adhesive was applied to bare sclera for attachment of amniotic membrane after removal of a conjunctival melanosis. All patients were followed up for 3 months after surgery. Tissue adhesion, corneal clarity, and visual acuity. All 5 lamellar grafts healed and remained clear, although final visual acuity varied with visual potential and astigmatism. The amniotic membrane graft also adhered well to the bare sclera. The fibrin adhesive provided satisfactory attachment without sutures for lamellar keratoplasty and amniotic patching. It should be effective for sealing of clear cornea incisions, LASIK flaps, and conjunctival and skin grafts. An adhesive that has been designed specifically for ophthalmic applications and is more convenient to use would be desirable.
Bou Monsef, Jad; Buckup, Johannes; Waldstein, Wenzel; Cornell, Charles; Boettner, Friedrich
2014-01-01
Reducing allogeneic blood transfusions remains a challenge in total knee arthroplasty. Patients with preoperative anemia have a particularly high risk for perioperative blood transfusions. 176 anemic patients (Hb < 13.5 g/dl) undergoing total knee replacement were prospectively evaluated to compare the effect of a perioperative cell saver (26 patients), intraoperative fibrin sealants (5 ml Evicel, Johnson & Johnson Wound Management, Ethicon, Somerville, NJ) (45 patients), preoperative autologous blood donation (PABD) (21 patients), the combination of fibrin sealants and preoperative autologous blood donation (44) and no intervention (40 patients) on perioperative blood loss and transfusion requirements. All protocols resulted in significant reduction of allogeneic blood transfusions. Transfusion rates were similar with the use of PABD (19%), Evicel (18%), and cell saver (19%), all significantly lower than the control group (38 %, p < 0.05). Combining Evicel with PABD resulted in significantly higher wastage of autologous units (p < 0.05) with no significant reduction in allogeneic transfusion rate (14%). The use of fibrin sealant resulted in a significant reduction of blood loss compared to the PABD group (603 vs. 810 ml, p < 0.005) as well as the control group (603 vs. 822 ml, p < 0.005). While PABD proved to be the most cost-effective treatment option in anemic patients, fibrin sealants and cell saver show similar reduction in allogeneic transfusion rates compared to controls. The combination of fibrin sealants and PABD is not cost-effective and increases the number of wasted units.
Shin, In Soo; Lee, Dong Won; Lew, Dae Hyun
2012-09-01
The extended latissimus dorsi flap is important for breast reconstruction. Unfortunately, donor site seroma is the most common complication of extended latissimus dorsi flap for breast reconstruction. Although using fibrin sealant in the donor site reduces the rate of seroma formation, donor site seroma remains a troublesome complication. The purpose of this study was to analyze the effectiveness of the combination of quilting sutures and fibrin sealant in the latissimus dorsi donor site for the prevention of seroma. Forty-six patients who underwent breast reconstruction with extended latissimus flap were enrolled in the study. The patients received either fibrin sealant (group 1, n=25) or a combination of fibrin sealant and quilting sutures (group 2, n=21) in the extended latissimus dorsi donor site. Outcome measures were obtained from the incidence, volume of postoperative seroma, total drainage amount, indwelling period of drainage, and duration of hospital stay. The incidence of seroma was 76% in group 1 and 42.9% in group 2 (P=0.022). We also found significant reductions in seroma volume (P=0.043), total drainage amount (P=0.002), indwelling period of drainage (P=0.01), and frequency of aspiration (P=0.043). The quilting sutures did not affect the rate of drainage, tube reinsertion, or hospital stay. The use of quilting sutures combined with fibrin sealant on the latissimus dorsi flap donor site is helpful for reducing the overall seroma volume, frequency of aspiration, and total drainage amount.
de Barros, Caio Nunes; Miluzzi Yamada, Ana Lúcia; Junior, Rui Seabra F; Barraviera, Benedito; Hussni, Carlos Alberto; de Souza, Jaqueline Brandão; Watanabe, Marcos Jun; Rodrigues, Celso Antônio
2015-01-01
Autologous fibrin gel is commonly used as a scaffold for filling defects in articular cartilage. This biomaterial can also be used as a sealant to control small hemorrhages and is especially helpful in situations where tissue reparation capacity is limited. In particular, fibrin can act as a scaffold for various cell types because it can accommodate cell migration, differentiation, and proliferation. Despite knowledge of the advantages of this biomaterial and mastery of the techniques required for its application, the durability of several types of sealant at the site of injury remains questionable. Due to the importance of such data for evaluating the quality and efficiency of fibrin gel formulations on its use as a scaffold, this study sought to analyze the heterologous fibrin sealant developed from the venom of Crotalus durissus terrificus using studies in ovine experimental models. The fibrin gel developed from the venom of this snake was shown to act as a safe, stable, and durable scaffold for up to seven days, without causing adverse side effects. Fibrin gel produced from the venom of the Crotalus durissus terrificus snake possesses many clinical and surgical uses. It presents the potential to be used as a biomaterial to help repair skin lesions or control bleeding, and it may also be used as a scaffold when applied together with various cell types. The intralesional use of the fibrin gel from the venom of this snake may improve surgical and clinical treatments in addition to being inexpensive and adequately consistent, durable, and stable. The new heterologous fibrin sealant is a scaffold candidate to cartilage repair in this study. PMID:26264444
Zhang, Wen-Gang; Linghu, En-Qiang; Li, Hui-Kai
2017-01-01
AIM To assess the efficacy and safety of fibrin sealant for closure of mucosal penetration at the cardia during peroral endoscopic myotomy (POEM). METHODS Twenty-four patients who underwent POEM and experienced mucosal injury of the cardia during the procedure were retrospectively identified. Of the 24 patients, 21 had mucosal penetration and 3 had only slight mucosal damage without penetration. The 21 patients with mucosal penetration received fibrin sealant for closure at the site of penetration. Penetration-related characteristics, treatment, and recovery were reviewed for all 21 patients to assess the efficacy and safety of fibrin sealant for closure of mucosal penetration at the cardia. Clinical data, including general characteristics, procedure-related parameters, Eckardt scores, lower esophageal sphincter pressures (LESP), and esophagogastroduodenoscopy (EGD) results, were analyzed to determine their influence on treatment success after mucosal penetration during POEM. RESULTS All 21 patients had a solitary mucosal penetration in the cardia (12 in esophageal region of the cardia, 9 in the stomach region of the cardia, and 1 in both the esophageal and stomach regions). Twelve had a hole-like penetration and 9 had a linear penetration. For those with a hole-like penetration, the mean size was 0.14 cm2 (0.02-0.32 cm2). For those with a linear penetration, the median size was 0.37 cm (0.10-1.00 cm). Closure of the mucosal penetration using fibrin sealant was performed successfully in all 21 patients (two patients required 5 mL fibrin sealant, and the remaining 19 patients required 2.5 mL). Two patients had a nasogastric tube placed for five days after POEM; the remaining 19 patients were kept fasting for 3 d. All 21 patients were discharged after a median of 5 d (range: 5-7 d) postoperatively. During a median 42 mo (range: 9-62 mo) follow-up, all 21 patients with a mucosal penetration successfully healed without the occurrence of infection, ulcer, or esophagitis. Furthermore, the median LESP decreased from 31.9 mmHg (range: 21.9-67.1 mmHg) preoperatively to 20.3 mmHg (range: 6.0-41.0 mmHg) postoperatively (P < 0.05). The median preoperative and postoperative Eckardt scores were 5.0 (range; 4-10) and 1.0 (range: 0-4), respectively (P < 0.05). Of the 21 patients with mucosal penetration, symptom remission, which is defined as a postoperative Eckardt score ≤ 3, was achieved in 20 patients (95.2%) indicating that mucosal penetration did not influence the success of POEM treatment if closed successfully using fibrin sealant. CONCLUSION Fibrin sealant is safe and effective for closure of mucosal penetration during POEM. Mucosal penetrations do not appear to influence the treatment success of POEM if closed successfully using fibrin sealant. Additional studies regarding the feasibility, efficacy, and safety of fibrin sealant for closure of larger mucosal penetrations is warranted. PMID:28321165
Do fibrin sealants impact negative outcomes after robot-assisted partial nephrectomy?
Cohen, Jason; Jayram, Gautam; Mullins, Jeffrey K; Ball, Mark W; Allaf, Mohamad E
2013-10-01
Contemporary rates of postoperative hemorrhage after partial nephrectomy (PN) are low. Commercially available hemostatic agents are commonly used during this surgery to reduce this risk despite a paucity of data supporting the practice. We assessed the impact of fibrin sealant hemostatic agents, a costly addition to surgeries, during robot-assisted partial nephrectomy (RAPN). Between 2007 and 2011, 114 consecutive patients underwent RAPN by a single surgeon (MEA). Evicel fibrin sealant was used in the first 74 patients during renorraphy. The last 40 patients had renorraphy performed without the use of any hemostatic agents. Clinicopathologic, operative, and complication data were compared between groups. Multivariate and univariate logistic regression analysis was performed to test the association between the use of fibrin sealants and operative outcomes. Patient demographic data and clinical tumor characteristics were similar between groups. The use of fibrin sealant did not increase operative time (166.3 vs 176.1 minutes, P=0.28), warm ischemia time (WIT) (14.4 vs 16.1 minutes, P=0.18), or length of hospital stay (2.6 vs 2.4 days, P=0.35). The omission of these agents did not increase estimated blood loss (116.6 vs 176.1 mL, P=0.8) or postoperative blood transfusion (0% vs 2.5%, P=0.17). Univariate analysis demonstrated no association between use of fibrin sealants and increased complications (P>0.05). Multivariable logistic regression showed no statistically significant predictive value of omission of hemostatic agents for perioperative outcomes (P>0.05). Perioperative hemorrhage and other major complications after contemporary RAPN are rare in experienced hands. In our study, the use of fibrin sealants during RAPN does not decrease the rate of complications, blood loss, or hospital stay. Furthermore, no impact is seen on operative time, WIT, or other negative outcomes. Omitting these agents during RAPN could be a safe, effective, cost-saving measure.
Mozafari, Roghayeh; Kyrylenko, Sergiy; Castro, Mateus Vidigal; Ferreira, Rui Seabra; Barraviera, Benedito; Oliveira, Alexandre Leite Rodrigues
2018-01-01
Peripheral nerve injury is a worldwide clinical problem, and the preferred surgical method for treating it is the end-to-end neurorrhaphy. When it is not possible due to a large nerve gap, autologous nerve grafting is used. However, these surgical techniques result in nerve regeneration at highly variable degrees. It is thus very important to seek complementary techniques to improve motor and sensory recovery. One promising approach could be cell therapy. Transplantation therapy with human embryonic stem cells (hESCs) is appealing because these cells are pluripotent and can differentiate into specialized cell types and have self-renewal ability. Therefore, the main objective of this study was to find conditions under which functional recovery is improved after sciatic nerve neurorrhaphy. We assumed that hESC, either alone or in combination with heterologous fibrin sealant scaffold, could be used to support regeneration in a mouse model of sciatic nerve injury and repair via autografting with end-to-end neurorrhaphy. Five millimeters of the sciatic nerve of C57BL/6 J mice were transected off and rotated 180 degrees to simulate an injury, and then stumps were sutured. Next, we applied heterologous fibrin sealant and/or human embryonic stem cells genetically altered to overexpress fibroblast growth factor 2 (FGF2) at the site of the injury. The study was designed to include six experimental groups comprising neurorrhaphy (N), neurorrhaphy + heterologous fibrin sealant (N + F), neurorrhaphy + heterologous fibrin sealant + doxycycline (N + F + D), neurorrhaphy + heterologous fibrin sealant + wild-type hESC (N + F + W), neurorrhaphy + heterologous fibrin sealant + hESC off (N + F + T), and neurorrhaphy + heterologous fibrin sealant + hESC on via doxycycline (N + F + D + T). We evaluated the recovery rate using Catwalk and von Frey functional recovery tests, as well as immunohistochemistry analysis. The experiments indicated that sensory function improved when transgenic hESCs were used. The regeneration of sensory fibers indeed led to increased reflexes, upon stimulation of the paw ipsilateral to the lesion, as seen by von-Frey evaluation, which was supported by immunohistochemistry. Overall, the present data demonstrated that transgenic embryonic stem cells, engineered to overexpress FGF-2 in an inducible fashion, could be employed to support regeneration aiming at the recovery of both motor and sensory functions.
Ferreira Junior, Rui Seabra
2016-01-01
Brachial plexus lesion results in loss of motor and sensory function, being more harmful in the neonate. Therefore, this study evaluated neuroprotection and regeneration after neonatal peripheral nerve coaptation with fibrin sealant. Thus, P2 neonatal Lewis rats were divided into three groups: AX: sciatic nerve axotomy (SNA) without treatment; AX+FS: SNA followed by end-to-end coaptation with fibrin sealant derived from snake venom; AX+CFS: SNA followed by end-to-end coaptation with commercial fibrin sealant. Results were analyzed 4, 8, and 12 weeks after lesion. Astrogliosis, microglial reaction, and synapse preservation were evaluated by immunohistochemistry. Neuronal survival, axonal regeneration, and ultrastructural changes at ventral spinal cord were also investigated. Sensory-motor recovery was behaviorally studied. Coaptation preserved synaptic covering on lesioned motoneurons and led to neuronal survival. Reactive gliosis and microglial reaction decreased in the same groups (AX+FS, AX+CFS) at 4 weeks. Regarding axonal regeneration, coaptation allowed recovery of greater number of myelinated fibers, with improved morphometric parameters. Preservation of inhibitory synaptic terminals was accompanied by significant improvement in the motor as well as in the nociceptive recovery. Overall, the present data suggest that acute repair of neonatal peripheral nerves with fibrin sealant results in neuroprotection and regeneration of motor and sensory axons. PMID:27446617
Parra-Membrives, Pablo; Martínez-Baena, Darío; Lorente-Herce, José Manuel; Martín-Balbuena, Ramón
2018-05-21
In spite of the acquired experience with laparoscopic common bile duct exploration (LCBDE) for choledocholithiasis management, there is still a risk of biliary leakage of 5% to 15% following choledochotomy closure. We evaluate the usefulness of fibrin-collagen sealants to reduce the incidence of biliary fistula after laparoscopic choledochorrhaphy. We report a retrospective analysis of 96 patients undergoing LCBDE from March 2009 to March 2017, whose closure of the bile duct was completed by antegrade stenting and choledochorraphy or by performing a primary suture. The study population was divided into two groups according to whether they received a collagen-fibrin sealant covering the choledochorrhaphy or not, analyzing the incidence of postoperative biliary fistula in each group. Thirty-nine patients (41%) received a fibrin-collagen sponge while the bile duct closure was not covered in the remaining 57 patients (59%). The incidence of biliary fistula was 7.7% (3 patients) in the first group and 14% (8 patients) in the second group (P=.338). In patients who underwent primary choledochorraphy, the fibrin-collagen sealant reduced the incidence of biliary leakage significantly (4.5% vs. 33%, P=.020), which was a protective factor with an odds ratio of 10.5. Fibrin-collagen sealants may decrease the incidence of biliary fistula in patients who have undergone primary bile duct closure following LCBDE. Copyright © 2018 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.
Hedrich, Hans Christian; Simunek, Manuela; Reisinger, Sonja; Ferguson, James; Gulle, Heinz; Goppelt, Andreas; Redl, Heinz
2012-08-01
In this study, we compared the sealing characteristics and efficacy of a fibrin sealant with reduced plasminogen (FS-rplg) and a fibrin sealant with aprotinin as a fibrinolysis inhibitor (FS-apr). The relevant sealing characteristics including clot structure, fibrin chain cross-linking, and clot lysis were tested in the laboratory. The sealing efficacy was then investigated in a follow-up animal model to determine differences in the in vivo sealing properties. A total of 46 animals were available for the final analysis with 23 animals in each treatment arm. In conclusion, we saw differences in vitro between FS-rplg and FS-apr in ultrastructure and α-chain cross-linking rates as well as in the rate of fibrinolysis. These differences may explain the significantly enhanced sealing efficacy in FS-apr compared to FS-rplg shown in vivo in a rabbit intestinal model. Copyright © 2012 Wiley Periodicals, Inc.
Plaga, B R; Royster, R M; Donigian, A M; Wright, G B; Caskey, P M
1992-03-01
We compared fibrin sealant, polydioxanone (PDS) pins and Kirschner wires in the fixation of osteochondral fractures in rabbit knees. Standardised osteochondral fractures of the right medial femoral condyle were made in 56 adult New Zealand white rabbits. There were equal groups of control knees, and those which had Kirschner-wire, fibrin-sealant or PDS-pin fixation. No external immobilisation was used. One animal from each group was killed at two, three and four weeks. The remaining rabbits were killed at six weeks. A fracture which healed with less than 1 mm of displacement was considered a success. There was successful healing in 29% of the control group, in all of the Kirschner-wire group, in 50% of the fibrin-sealant group, and in 86% of the PDS-pin group. The use of PDS pins appears to be a reliable alternative to the use of metal in the fixation of osteochondral fractures in rabbits.
2014-01-01
The objective of this study was to evaluate the efficacy and safety of fibrin sealant in patients following total knee arthroplasty (TKA). A comprehensive literature search of the electronic databases PubMed, MEDLINE, Web of Science, and Cochrane Library for published randomized controlled trials (RCTs) was undertaken. The evidence base was critically appraised using a tool from the Cochrane Bone, Joint and Muscle Trauma Group. Eight RCTs involving 641 patients were included. The use of fibrin sealant significantly reduced postoperative drainage (weighted mean difference (WMD) −346, 95% confidence interval (CI) −496.29 to −197.54, P < 0.00001) and blood transfusions (risk ratio (RR) 0.47, 95% CI 0.35 to 0.63, P < 0.00001) and led to a significant improvement in the range of motion (WMD 16.59, 95% CI 6.92 to 26.25, P = 0.0008). However, using fibrin sealant did not significantly reduced total blood loss (WMD −305.25, 95% CI −679.44 to 68.95, P = 0.11). Regarding complications, there were no significant differences in any adverse events, fever, infection, or hematoma among the study groups. In conclusion, the present meta-analysis indicates that the use of fibrin sealant was effective and safe as a hemostatic therapy for patients with TKA. PMID:24884626
Marchi, Evaldo; de Carvalho, Marcus V H; Ventureli, Tiago R; Fruchi, Andre J; Lazaro, Ariane; do Carmo, Deborah C; Barreto, Thayssa Y A S; Dias, Bruno V B; Acencio, Milena M P; Teixeira, Lisete R; Light, Richard W
2016-09-01
Pleurodesis performed either by pleurectomy or pleural abrasion is recommended in the approach to primary spontaneous pneumothorax to avoid recurrence. However, the efficacy of parietal pleural abrasion in producing pleurodesis is questioned. This study aims to determine the efficacy of apical abrasion alone, abrasion plus fibrin sealant application, and pleurectomy in producing pleurodesis in rabbits. Rabbits were subjected to video-assisted thoracic surgery alone (control) or to video-assisted thoracic surgery with apical gauze abrasion, abrasion plus fibrin sealant instillation, or apical pleurectomy. Blood samples were collected preoperatively and 48 h and 28 days postoperatively to measure total leukocytes (white blood cell count), neutrophil counts, and serum interleukin (IL)-8 levels. After 28 days the animals were sacrificed for macroscopic evaluation of the degree of apical pleurodesis and microscopic evaluation of local pleural fibrosis and collagen deposition. White blood cell and neutrophil counts were similar in all groups, whereas the serum IL-8 level peaked at 48 h in all groups and decreased after 28 days, except in the pleurectomy group. After 28 days the abrasion plus fibrin sealant and pleurectomy groups had significantly more pleural adhesions, pleural fibrosis, and collagen deposition than the abrasion alone group, mainly due to thick mature fibers. Abrasion with local fibrin sealant instillation is as effective as pleurectomy in producing pleurodesis in rabbits. Apical pleurectomy elicits a more persistent elevation of serum IL-8 levels than apical abrasion alone or abrasion plus fibrin adhesive instillation. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
Fibrin Tissue Sealant as an Adjunct to Cleft Palate Repair.
Wu, Robin; Wilson, Alexander; Travieso, Roberto; Steinbacher, Derek M
2017-07-01
Fibrin glue is a common tissue sealant used to promote hemostasis, adhere tissues, and accelerate healing. Cleft palate repair can be technically challenging, creating dead space between tissue planes, and can be prone to complications such as would dehiscence or bleeding. The purpose of this study is to assess the role of fibrin glue as an adjunct to cleft palate repair. The authors hypothesize a beneficial impact on complication rates, including bleeding, dehiscence, and fistula formation, among others. Primary cleft palate repairs using fibrin glue were retrospectively analyzed. Demographic, intraoperative, perioperative, and postoperative data were combed for outcome variables. Complication rates were calculated in percentages and the results were compared to the published literature. Z-test statistics were performed for comparison. A total of 45 patients, 21 females and 24 males, who underwent primary cleft palate repair with fibrin glue between 2011 and 2014, had sufficient data to be reviewed. There were no instances of bleeding, dehiscence, airway obstruction, infection, oronasal fistula, or return to the operating room in any patients. One patient exhibited mild postoperative coughing and secretions that resolved with conservative measures. Another patient displayed postoperative seizure activity due to a pre-existing condition. All complication rates in our fibrin glue series were lower than those reported without the use of fibrin glue. Overall complication rates with fibrin sealant are significantly lower than overall complication rates without. Our data suggest that fibrin sealant is a beneficial adjunct to cleft palate repair. Its application is well-tolerated and the complication profile in our cohort was much less than the reported rates. The results of this preliminary study should be vetted with a prospective analysis involving a control group.
[Eosinophilic pleural effusion possibly induced by fibrin sealant].
Kambayashi, Takatoyo; Suzuki, Takashi
2012-02-01
A 74-year-old man underwent right upper lobectomy for the lung cancer and bullectomy of right lower lobe. Fibrin sealant was used for sealing the excision line. The increase of the pleural effusion with increasing C-reactive protein( CRP) and eosinophilia was noted at the 17th day after the operation. The pleural effusion was transparent and yellowish colored suggesting transudatory liquid. The eosinophil in the pleural effusion was as high as 14%. The drainage of the pleural effusion was performed for 2 days resulting in disappearing the abnormal accumulation without any additional treatment. The cause of pleural effusion was supposed to be fibrin sealant by a positive result of the drug lymphocyte stimulation test.
Hickerson, William L; Nur, Israel; Meidler, Roberto
2011-01-01
The objective of the present study was to compare the mechanical, kinetic, and biochemical properties of fibrin clots produced using EVICEL Fibrin Sealant (Human) and TISSEEL Fibrin Sealant. The stiffness/elasticity and strength of fibrin clots formed with EVICEL and TISSEEL were assessed using applied mechanical force and thromboelastography (TEG). The factor XIII content of the fibrin clots was also evaluated. Mean Young modulus and tensile strength of the fibrin clots produced by EVICEL were significantly higher than those of clots produced by TISSEEL (P < 0.05 for both). The mean time to initial clot formation and mean time to the predefined level of clot formation were numerically shorter for EVICEL compared with TISSEEL. Furthermore, mean maximal amplitude of the clots formed with EVICEL was significantly greater than that for the clots formed with TISSEEL. Mean concentration of factor XIII for the EVICEL fibrinogen samples tested was 9 IU/ml compared with undetectable concentrations of factor XIII for the TISSEEL fibrinogen samples. Fibrin clots formed with EVICEL have a much higher resistance to stretching and tensile strength and are more capable of maintaining their structure against applied force than those formed with TISSEEL. EVICEL also allows more rapid development of fibrin clots than TISSEEL. This superior clot strength and resilience obtained with EVICEL relative to TISSEEL may be due in large part to the presence of factor XIII.
Srinivas, B. V. V.; Rupa, N.; Halini Kumari, K. V.; Rajender, A.; Reddy, M. Narendra
2015-01-01
Periodontal plastic surgery is the branch of periodontology that is focused mainly on the correction or elimination of mucogingival problems associated with lack of attached gingiva, a shallow vestibule and aberrant frenum. Various mucogingival surgical procedures are used to halt the progression of the gingival recession and to correct poor esthetic appearance. Free gingival autograft is one of the most common techniques used for a gingival recession in areas of inadequate attached gingiva in the mandibular anterior region. Fibrin sealants are human plasma derivatives that mimic the final stages of blood coagulation, forming a fibrin clot. Fibrin Sealants enhances the overall outcome of surgical intervention because of their hemostatic, adhesive, and healing properties. These properties of fibrin sealants may reduce operating time, prevent complications, and enhance the overall outcome of many surgical interventions. Hence, this case report aims to investigate the clinical effectiveness of free gingival graft along with the commercially available fibrin-fibronectin sealing system (Tissucol®) in the treatment of Miller's class II gingival recession. PMID:26538956
A method to determine shear adhesive strength of fibrin sealants.
Sierra, D H; Feldman, D S; Saltz, R; Huang, S
1992-01-01
The adhesive strength of fibrin sealants has not been rigorously evaluated to date. The adhesive strength of six different concentrations of cryoprecipitated fibrinogen as well as the commercially available fibrin tissue adhesive Tissucol was tested under controlled conditions utilizing split-thickness skin grafts as the test adherand. This test configuration permitted the modeling of bonding strength for attachment of skin grafts as well as incorporate established engineering test standards for adhesives. An increase in fibrin concentration corresponded with an increase in shear adhesive strength. No significant increases in adhesive strength were attained after 5 min of bonding for all tested concentrations, except for the commercial adhesive, which attained the adhesive strength of an equivalent concentration of cryoprecipitated adhesive after 90 min. The adhesive strength, however, was an order of magnitude less than reported values of the tensile strength of fibrin material for similar concentrations. Therefore, it is important that the surgeon use a sufficiently high fibrinogen concentration for the specific clinical indication. The method of fibrin sealant preparation and/or the compounding adjuncts appear to have an effect on the development of adhesive strength.
Fibrin sealant: past, present, and future: a brief review.
Spotnitz, William D
2010-04-01
Fibrin sealant is a two-component topical hemostat, sealant, and tissue adhesive consisting of fibrinogen and thrombin that has been used in the United States as a blood bank- or laboratory-derived product since the 1980s and has been commercially available since 1998. Initially, surgeons employed hospital-based materials because of the lack of availability of a commercially produced agent. At present, there are five U.S. Food and Drug Administration (FDA)-approved forms including products derived from pooled or autologous human plasma as well as bovine plasma. On-label indications include hemostasis, colonic sealing, and skin graft attachment. Recent clinical and experimental uses include tissue or mesh attachment, fistula closure, lymphatic sealing, adhesion prevention, drug delivery, and tissue engineering. The modern literature on fibrin sealant now exceeds 3000 articles and continues to expand. This brief review presents the history of this material, its present clinical use, and its future applications.
Angelini, Pierluigi; Sciuto, Antonio; Cuccurullo, Diego; Pirozzi, Felice; Reggio, Stefano; Corcione, Francesco
2017-07-01
Laparoscopy has increasingly become the standard of care for patients who undergo colorectal surgery for both benign and malignant diseases. This growing experience has also resulted in more reports of postoperative complications from the minimally invasive approach to primary colorectal resection. Small bowel obstruction from internal hernias and pre-sacral adhesions is an uncommon but not negligible complication. However, there is little literature specific to this topic with recommendations for different methods to prevent it. We report our original technique of closing the mesenteric defect and covering the pre-sacral fascia by using fibrin sealant to prevent this complication. From January 2005 to December 2014, a total of 1079 patients underwent elective laparoscopic left colorectal resection (left hemicolectomy or anterior rectal resection) in our department. In the first 298 procedures, the mesenteric defect was left open, while in the following 781 procedures, it was closed using fibrin sealant with the aim of preventing postoperative small bowel obstruction. Among the first 298 patients, three (1%) required reoperation for small bowel obstruction due to internal hernia (0.33%) or critical pre-sacral adhesions (0.66%). These complications did not occur in the subsequent series in which all 781 patients were treated with fibrin sealant prophylactic closure of the mesenteric defect. In our experience, fibrin sealant closure of the mesenteric defect has demonstrated to be safe and effective in preventing postoperative small bowel obstruction that remains a complication both in open and in laparoscopic colorectal surgeries.
Use of fibrin sealants for the localized, controlled release of cefazolin
Tredwell, Stephen; Jackson, John K.; Hamilton, Donald; Lee, Vivian; Burt, Helen M.
2006-01-01
Background Fibrin sealants are used increasingly in surgery to reduce bleeding and improve wound healing. They have great potential as biocompatible, biodegradable drug delivery systems, because the sealant may adhere to the target tissue and allow controlled release of the drug over an extended period. We investigated the encapsulation, stability and controlled release of erythromycin and cefazolin from Beriplast fibrin sealants (Aventis Behring Canada). Methods Drug-loaded clots were cast in glass vials and allowed to set. We observed the clots for drug precipitation and aggregation, and we assessed the effect of drug encapsulation on clot strength. Drug stability and release from the clots in phosphate buffered saline (PBS) was quantified by ultraviolet and visible violet absorbance spectroscopy and high-performance liquid chromatography. Results Erythromycin was found to release slowly from the fibrin clots over the first 2 hours but then degrade rapidly. Cefazolin was found to be very stable in clots in PBS (97% stable at 2 d and 93% stable at 5 d). The drug released in a controlled manner over 2 days, with most being released during the first day. The dose of drug released could be varied by changing the amount placed in the thrombin solution. Clot thickness had no effect on the rate of cefazolin release. Conclusion Overall, the 2-day release profile and the excellent stability of the drug suggest that cefazolin-loaded fibrin sealants may offer an effective route of postoperative antibiotic delivery. PMID:17152573
Fortelny, René H.; Petter-Puchner, Alexander H.; Redl, Heinz; May, Christopher; Pospischil, Wolfgang; Glaser, Karl
2014-01-01
Background: Inguinal hernia repair is one of the most common operations in general surgery. The Lichtenstein tension-free operation has become the gold standard in open inguinal hernia repair. Despite the low recurrence rates, pain and discomfort remain a problem for a large number of patients. The aim of this study was to compare suture fixation vs. fibrin sealing by using a new monofilament PTFE mesh, i.e., the Infinit® mesh by W. L. Gore & Associates. Methods: This study was designed as a controlled prospective single-center two-cohort study. A total of 38 patients were enrolled and operated in Lichtenstein technique either standard suture mesh fixation or fibrin-sealant mesh fixation were used as described in the TIMELI trial. Primary outcome parameters were postoperative complications with the new mesh (i.e., seroma, infection), pain, and quality of life evaluated by the VAS and the SF-36 questionnaire. Secondary outcome was recurrence assessed by ultrasound and physical examination. Follow-up time was 1 year. Results: Significantly, less postoperative pain was reported in the fibrin-sealant group compared to the suture group at 6 weeks (P = 0.035), 6 months (P = 0.023), and 1 year (P = 0.011) postoperatively. Additionally, trends toward a higher postoperative quality of life, a faster surgical procedure, and a shorter hospital stay were seen in the fibrin-sealant group. Conclusion: Fibrin-sealant mesh fixation in Lichtenstein hernioplasty effectively reduces acute and chronic postoperative pain. Monofilament, macro-porous, knitted PTFE meshes seem to be a practicable alternative to commonly used polypropylene meshes in open inguinal hernia repair. PMID:25593969
Fortelny, René H; Petter-Puchner, Alexander H; Redl, Heinz; May, Christopher; Pospischil, Wolfgang; Glaser, Karl
2014-01-01
Inguinal hernia repair is one of the most common operations in general surgery. The Lichtenstein tension-free operation has become the gold standard in open inguinal hernia repair. Despite the low recurrence rates, pain and discomfort remain a problem for a large number of patients. The aim of this study was to compare suture fixation vs. fibrin sealing by using a new monofilament PTFE mesh, i.e., the Infinit(®) mesh by W. L. Gore & Associates. This study was designed as a controlled prospective single-center two-cohort study. A total of 38 patients were enrolled and operated in Lichtenstein technique either standard suture mesh fixation or fibrin-sealant mesh fixation were used as described in the TIMELI trial. Primary outcome parameters were postoperative complications with the new mesh (i.e., seroma, infection), pain, and quality of life evaluated by the VAS and the SF-36 questionnaire. Secondary outcome was recurrence assessed by ultrasound and physical examination. Follow-up time was 1 year. Significantly, less postoperative pain was reported in the fibrin-sealant group compared to the suture group at 6 weeks (P = 0.035), 6 months (P = 0.023), and 1 year (P = 0.011) postoperatively. Additionally, trends toward a higher postoperative quality of life, a faster surgical procedure, and a shorter hospital stay were seen in the fibrin-sealant group. Fibrin-sealant mesh fixation in Lichtenstein hernioplasty effectively reduces acute and chronic postoperative pain. Monofilament, macro-porous, knitted PTFE meshes seem to be a practicable alternative to commonly used polypropylene meshes in open inguinal hernia repair.
A fibrin sealant for perforated and preperforated corneal ulcers.
Lagoutte, F M; Gauthier, L; Comte, P R
1989-01-01
Fibrin sealant is used to close perforated or preperforated corneal ulcers. In addition to the usual advantages of cyanoacrylates it is degraded physiologically and provides a good support for corneal healing. Corneal grafting can be avoided when contraindicated or postponed when conditions allow. This technique has been successful in nine eyes of eight patients. Images PMID:2804032
Reduction of the closure time of postoperative enterocutaneous fistulas with fibrin sealant.
Avalos-González, Jorge; Portilla-deBuen, Eliseo; Leal-Cortés, Caridad Aurea; Orozco-Mosqueda, Abel; Estrada-Aguilar, María del Carmen; Velázquez-Ramírez, Gabriela Abigail; Ambriz-González, Gabriela; Fuentes-Orozco, Clotilde; Guzmán-Gurrola, Aldo Emmerson; González-Ojeda, Alejandro
2010-06-14
To assess whether the use of fibrin sealant shortens the closure time of postoperative enterocutaneous fistulas (ECFs). The prospective case-control study included 70 patients with postoperative ECFs with an output of < 500 mL/d, a fistulous tract of > 2 cm and without any local complication. They were divided into study (n = 23) and control groups (n = 47). Esophageal, gastric and colocutaneous fistulas were monitored under endoscopic visualization, which also allowed fibrin glue application directly through the external hole. Outcome variables included closure time, time to resume oral feeding and morbidity related to nutritional support. There were no differences in mean age, fistula output, and follow-up. Closure-time for all patients of the study group was 12.5 +/- 14.2 d and 32.5 +/- 17.9 d for the control group (P < 0.001), and morbidity related to nutritional support was 8.6% and 42.5%, respectively (P < 0.01). In patients with colonic fistulas, complete closure occurred 23.5 +/- 19.5 d after the first application of fibrin glue, and spontaneous closure was observed after 36.2 +/- 22.8 d in the control group (P = 0.36). Recurrences were observed in 2 patients because of residual disease. One patient of each group died during follow-up as a consequence of septic complications related to parenteral nutrition. Closure time was significantly reduced with the use of fibrin sealant, and oral feeding was resumed faster. We suggest the use of fibrin sealant for the management of stable enterocutaneous fistulas.
Efficacy and safety of fibrin sealant patch in the treatment of air leakage in thoracic surgery.
Lopez, C; Facciolo, F; Lequaglie, C; Rendina, E A; Saita, S; Dell'Amore, D; Sollitto, F; Urciuoli, G; Loizzi, M; Cisternino, M L; Granone, P; Angelelli, A; Cardillo, G; Mucilli, F; Di Rienzo, G
2013-12-01
Air leakage represents a major problem in lung surgery. Absorbable fibrin sealant patch (AFSP), a collagen sponge coated with human fibrinogen and thrombin, can be used as an adjunct to primary stapling or suturing. This study compared the efficacy of AFSP with manual suturing after primary stapling. This was a prospective, multicenter, randomized study. Patients undergoing lobectomy, bilobectomy, anatomical segmentectomy for lung cancer or wedge resection for pulmonary metastasis with air leakage grade 1 or 2 according to Macchiarini scale after stapler suture were randomized to receive AFSP or standard surgical treatment (ST). The primary endpoint was the reduction of intraoperative air leakage intensity. Duration of postoperative air leakage and number of days until removal of last chest drain were secondary endpoints. Safety was recorded for all patients. A total of 346 patients were enrolled in 14 centres, 179 of whom received AFSP and 167 ST. Intraoperative air leak intensity was reduced in 90.5% of AFSP patients and 82% of ST patients (P=0.03). A significant reduction in postoperative air leakage duration was observed in the AFSP group (P=0.0437). The median number of days until removal of last drainage was 6 (3-37) in the AFSP group and 7 (2-27) in the ST (P=0.38). Occurrence of adverse events was comparable in both groups. AFSP was more efficacious than standard ST as an adjunct to primary stapling in reducing intraoperative air leakage intensity and duration of postoperative air leakage in patients undergoing pulmonary surgery. AFSP was well tolerated.
Hypersensitivity to sub-Tenon's topotecan in fibrin adhesive in patients with retinoblastoma.
Astudillo, Paulita Pamela P; Durairaj, Priya; Chan, Helen S L; Héon, Elise; Gallie, Brenda L
2015-02-01
Sub-Tenon's space delivery of topotecan in a fibrin sealant was used as an adjunct to laser therapy for small retinoblastoma tumors in 25 children (77 injections). We report serious hypersensitivity reactions in 2 children on their third sub-Tenon's injection of topotecan in fibrin sealant. One child subsequently had topotecan in an autologous blood clot with no allergic reaction. Although allergic reaction to topotecan has been reported in the literature, fibrin glue reactions are more common and are likely due to aprotinin hypersensitivity. Copyright © 2015 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.
Barbizan, Roberta; Seabra Ferreira, Rui
2016-01-01
Axonal injuries at the interface between central and peripheral nervous system, such as ventral root avulsion (VRA), induce important degenerative processes, mostly resulting in neuronal and motor function loss. In the present work, we have compared two different fibrin sealants, one derived from human blood and another derived from animal blood and Crotalus durissus terrificus venom, as a promising treatment for this type of injury. Lewis rats were submitted to VRA (L4–L6) and had the avulsed roots reimplanted to the surface of the spinal cord, with the aid of fibrin sealant. The spinal cords were processed to evaluate neuronal survival, synaptic stability, and glial reactivity, 4 and 12 weeks after lesion. Sciatic nerves were processed to investigate Schwann cell activity by p75NTR expression (4 weeks after surgery) and to count myelinated axons and morphometric evaluation (12 weeks after surgery). Walking track test was used to evaluate gait recovery, up to 12 weeks. The results indicate that both fibrin sealants are similarly efficient. However, the snake-derived fibrin glue is a potentially safer alternative for being a biological and biodegradable product which does not contain human blood derivatives. Therefore, the venom glue can be a useful tool for the scientific community due to its advantages and variety of applications. PMID:27642524
Reduction of the closure time of postoperative enterocutaneous fistulas with fibrin sealant
Avalos-González, Jorge; Portilla-deBuen, Eliseo; Leal-Cortés, Caridad Aurea; Orozco-Mosqueda, Abel; del Carmen Estrada-Aguilar, María; Velázquez-Ramírez, Gabriela Abigail; Ambriz-González, Gabriela; Fuentes-Orozco, Clotilde; Guzmán-Gurrola, Aldo Emmerson; González-Ojeda, Alejandro
2010-01-01
AIM: To assess whether the use of fibrin sealant shortens the closure time of postoperative enterocutaneous fistulas (ECFs). METHODS: The prospective case-control study included 70 patients with postoperative ECFs with an output of < 500 mL/d, a fistulous tract of > 2 cm and without any local complication. They were divided into study (n = 23) and control groups (n = 47). Esophageal, gastric and colocutaneous fistulas were monitored under endoscopic visualization, which also allowed fibrin glue application directly through the external hole. Outcome variables included closure time, time to resume oral feeding and morbidity related to nutritional support. RESULTS: There were no differences in mean age, fistula output, and follow-up. Closure-time for all patients of the study group was 12.5 ± 14.2 d and 32.5 ± 17.9 d for the control group (P < 0.001), and morbidity related to nutritional support was 8.6% and 42.5%, respectively (P < 0.01). In patients with colonic fistulas, complete closure occurred 23.5 ± 19.5 d after the first application of fibrin glue, and spontaneous closure was observed after 36.2 ± 22.8 d in the control group (P = 0.36). Recurrences were observed in 2 patients because of residual disease. One patient of each group died during follow-up as a consequence of septic complications related to parenteral nutrition. CONCLUSION: Closure time was significantly reduced with the use of fibrin sealant, and oral feeding was resumed faster. We suggest the use of fibrin sealant for the management of stable enterocutaneous fistulas. PMID:20533600
Failure mechanisms of fibrin-based surgical tissue adhesives
NASA Astrophysics Data System (ADS)
Sierra, David Hugh
A series of studies was performed to investigate the potential impact of heterogeneity in the matrix of multiple-component fibrin-based tissue adhesives upon their mechanical and biomechanical properties both in vivo and in vitro. Investigations into the failure mechanisms by stereological techniques demonstrated that heterogeneity could be measured quantitatively and that the variation in heterogeneity could be altered both by the means of component mixing and delivery and by the formulation of the sealant. Ex vivo tensile adhesive strength was found to be inversely proportional to the amount of heterogeneity. In contrast, in vivo tensile wound-closure strength was found to be relatively unaffected by the degree of heterogeneity, while in vivo parenchymal organ hemostasis in rabbits was found to be affected: greater heterogeneity appeared to correlate with an increase in hemostasis time and amount of sealant necessary to effect hemostasis. Tensile testing of the bulk sealant showed that mechanical parameters were proportional to fibrin concentration and that the physical characteristics of the failure supported a ductile mechanism. Strain hardening as a function of percentage of strain, and strain rate was observed for both concentrations, and syneresis was observed at low strain rates for the lower fibrin concentration. Blister testing demonstrated that burst pressure and failure energy were proportional to fibrin concentration and decreased with increasing flow rate. Higher fibrin concentration demonstrated predominately compact morphology debonds with cohesive failure loci, demonstrating shear or viscous failure in a viscoelastic rubbery adhesive. The lower fibrin concentration sealant exhibited predominately fractal morphology debonds with cohesive failure loci, supporting an elastoviscous material condition. The failure mechanism for these was hypothesized and shown to be flow-induced ductile fracture. Based on these findings, the failure mechanism was stochastic in nature because the mean failure energy and burst pressure values were not predictive of locus and morphology. Instead, flow rate and fibrin concentration showed the most predictive value, with the outcome best described as a probability distribution rather than a specific deterministic outcome.
Moser, C; Opitz, I; Zhai, W; Rousson, V; Russi, E W; Weder, W; Lardinois, D
2008-10-01
Prolonged air leak is reported in up to 50% of patients after lung volume reduction surgery. The effect of an autologous fibrin sealant on the intensity and duration of air leak and on the time to chest drain removal after lung volume reduction surgery was investigated in a randomized prospective clinical trial. Twenty-five patients underwent bilateral thoracoscopic lung volume reduction surgery. In each patient, an autologous fibrin sealant was applied along the staple lines on one side, whereas no additional measure was taken on the other side. Randomization of treatment was performed at the end of the resection on the first side. Air leak was assessed semiquantitatively by use of a severity score (0 = no leak; 4 = continuous severe leak) by two investigators blinded to the treatment. Mean value of the total severity scores for the first 48 hours postoperative was significantly lower in the treated group (4.7 +/- 7.7) than in the control group (16.0 +/- 10.1) (P < .001), independently of the length of the resection. Prolonged air leak and mean duration of drainage were also significantly reduced after application of the sealant (4.5% and 2.8 +/- 1.9 days versus 31.8% and 5.9 +/- 2.9 days) (P = .03 and P < .001). Autologous fibrin sealant for reinforcement of the staple lines after lung volume reduction surgery significantly reduces prolonged air leak and duration of chest tube drainage.
Luu, A M; Braumann, C; Belyaev, O; Janot, M; Uhl, W; Herzog, T
2016-12-01
Background: Postoperative pancreatic fistulas (POPF) remain a major concern after distal pancreatectomy. Irrespective of the technique to close the pancreatic remnant, pancreatic fistulas will occur in approximately 30 % of patients undergoing distal pancreatectomy. For the first time ever, autologous fibrin sealant (Vivostat®) was used to additionally seal the pancreatic remnant after a distal pancreatectomy. The aim was to analyse whether this changes the postoperative outcome. Patients/Material and Methods: In 2015, a technical case series was performed in 15 patients who underwent distal pancreatectomy. The pancreatic remnant was additionally sealed with autologous fibrin sealant (Vivostat®). Results: A postoperative pancreatic fistula (POPF) occurred in 5/15 patients (33 %). One patient had a POPF grade A (1/15, 6.7 %), whereas a POPF grade B occurred in 4/15 patients (26.7 %). 75 % (3/4) of the patients with a POPF grade B were sufficiently treated with antibiotics, whereas a CT-guided percutaneous drainage had to be placed only in one case. Conclusion: Autologous fibrin sealant is simple to apply and seems to be well tolerated. However, it does not seem to avoid the development of postoperative pancreatic fistulas after distal pancreatectomy. Georg Thieme Verlag KG Stuttgart · New York.
Ryttlefors, Mats; Latini, Francesco; Basma, Jaafar; Krisht, Ali F
2016-07-01
Objective Recurrent brain tumors represent a challenge for neurosurgeons because of the extensive blood loss and the time needed for surgical resection. Only a few hemostatic agents are useful to prevent the bleeding and thus facilitate the surgical resection. Fibrin sealant can be used to achieve sealing, tissue adherence, or hemostasis when other means of hemostasis are inadequate or inappropriate. We report the feasibility and positive effects of direct intratumoral injection of fibrin sealant during resection of a recurrent hemangiopericytoma. Material and Methods The intraoperative intratumoral injection of fibrin sealant changed the tumor properties of a recurrent hemangiopericytoma of the tentorium with infra- and supratentorial extension. From a loose friable briskly bleeding tumor, this complex lesion became a nonbleeding well-demarcated soft-firm tumor that could easily be dissected off the pial surface and totally resected without extensive bleeding. Results There are several benefits of intratumoral injection of fibrin sealant in hemangiopericytomas: (1) the extensive bleeding is diminished and blood loss minimized; (2) the restriction of the surgical view by the venous oozing is diminished, making the microsurgical dissection of the tumor capsule off the pial surface easier and safer; (3) the loose consistency of the tumor becomes firmer and facilitates the manipulation of the tumor and leads to a safer resection; and (4) a shorter operating time is needed. Conclusion The use of intratumoral fibrin glue injection is a safe and useful technique that could be used for hemostasis of highly vascularized tumors to facilitate a safer resection and to reduce blood loss. Georg Thieme Verlag KG Stuttgart · New York.
Protective fibrin-sealed plication of the small bowel in recurrent laparotomy.
Holland-Cunz, S; Boelter, A V; Waag, K L
2003-09-01
Adhesions after recurrent abdominal operations remain extremely common and are sources of severe morbidity. Fibrin-glued plication of the small gut in a meander-like formation is supposed to guarantee a decreased risk of intestinal obstruction postoperatively. This retrospective study analyses the clinical outcome after recurrent laparotomy in children treated with bowel plication by fibrin sealant. The surgical technique of performing the fibrin-glued plication is rather simple and quick: after taking off all adhesions two to four loops of the small gut are positioned so that they lie side by side. Beginning proximal fibrin [Tissucol fibrin sealant (Baxter)] is applied between the loops; approximately 20-30 s are needed to keep the loops in position until the fibrin dries. This manoeuvre is continued until all of the small gut is fixed in one block. The gut is brought back into the abdominal cavity without loosening the loops. This fixed formation by sero-serosal adhesions or mesenterial plications is supposed to guarantee postoperative free passage. The charts of 60 children who had undergone a fibrin plication of the small bowel between 1991 and 1999 were evaluated. Additionally, questionnaires were sent to all patients, and they were invited for an examination. Sixty patients (38 boys and 22 girls) received a fibrin sealant plication because of recurrent laparotomies with heavily serosal defects or recurrent ileus because of adhesions. The youngest baby was 10 days. Since 23 patients were premature the oldest patient was 11 years old. There were no intraoperative complications attributed to the method. In the postoperative period 7/60 (12%) patients had a recurrent ileus or subileus, leading in three (5%) patients to an early relaparotomy. The fibrin-glued plication of the small bowel decreases the risk of recurrent ileus or subileus considering the high figures in the literature concerning this issue. The time-saving method is very simple and easily feasible. No side effects after the treatment with fibrin glue were observed.
Park, Tae Hyun; Kim, Jin Kyu
2016-02-01
Most pneumatoceles disappear spontaneously and do not cause severe symptoms. Treatment alternatives include various conventional or surgical methods. However, an enlarging, complicated pneumatocele with cardiorespiratory instability requires imaging-guided catheter drainage or surgery. Here, we report the case of a newborn girl with an enlarging pneumatocele accompanied by pulmonary interstitial emphysema secondary to mechanical ventilation. The pneumatocele was successfully managed by the injection of fibrin sealant via a pigtail catheter. © 2015 Wiley Periodicals, Inc.
Fujioka-Kobayashi, Masako; Mottini, Matthias; Kobayashi, Eizaburo; Zhang, Yufeng; Schaller, Benoit; Miron, Richard J
2017-01-01
In the craniofacial bone field, fibrin sealants are used as coagulant and adhesive tools to stabilize grafts during surgery. Despite this, their exact role in osteogenesis is poorly characterized. In the present study, we aimed to characterize the osteogenic potential of TISSEEL fibrin sealant and used its technology to incorporate growth factors within its matrix. We focused on recombinant human bone morphogenetic protein (rhBMP)-9, which has previously been characterized as one of the strongest osteogenetic inducers in the BMP family. TISSEEL displayed an excellent ability to retain rhBMP9, which was gradually released over a 10-day period. Although TISSEEL decreased bone stromal ST2 cell attachment at 8 h, it displayed normal cell proliferation at 1, 3, and 5 days when compared to tissue culture plastic. Interestingly, TISSEEL had little influence on osteoblast differentiation; however its combination with rhBMP9 significantly increased ALP activity at 7 days, Alizarin Red staining at 14 days, and mRNA levels of osteoblast differentiation markers ALP, bone sialoprotein, and osteocalcin. In summary, although fibrin sealants were shown to have little influence on osteogenesis, their combination with bone-inducing growth factors such as rhBMP9 may serve as an attractive carrier/scaffold for future bone regenerative strategies. Future animal studies are now necessary. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Buchaim, Daniela Vieira; Rodrigues, Antonio de Castro; Buchaim, Rogerio Leone; Barraviera, Benedito; Junior, Rui Seabra Ferreira; Junior, Geraldo Marco Rosa; Bueno, Cleuber Rodrigo de Souza; Roque, Domingos Donizeti; Dias, Daniel Ventura; Dare, Leticia Rossi; Andreo, Jesus Carlos
2016-07-01
This study aimed to evaluate the effects of low-level laser therapy (LLLT) in the repair of the buccal branch of the facial nerve with two surgical techniques: end-to-end epineural suture and coaptation with heterologous fibrin sealant. Forty-two male Wistar rats were randomly divided into five groups: control group (CG) in which the buccal branch of the facial nerve was collected without injury; (2) experimental group with suture (EGS) and experimental group with fibrin (EGF): The buccal branch of the facial nerve was transected on both sides of the face. End-to-end suture was performed on the right side and fibrin sealant on the left side; (3) Experimental group with suture and laser (EGSL) and experimental group with fibrin and laser (EGFL). All animals underwent the same surgical procedures in the EGS and EGF groups, in combination with the application of LLLT (wavelength of 830 nm, 30 mW optical power output of potency, and energy density of 6 J/cm(2)). The animals of the five groups were euthanized at 5 weeks post-surgery and 10 weeks post-surgery. Axonal sprouting was observed in the distal stump of the facial nerve in all experimental groups. The observed morphology was similar to the fibers of the control group, with a predominance of myelinated fibers. In the final period of the experiment, the EGSL presented the closest results to the CG, in all variables measured, except in the axon area. Both surgical techniques analyzed were effective in the treatment of peripheral nerve injuries, where the use of fibrin sealant allowed the manipulation of the nerve stumps without trauma. LLLT exhibited satisfactory results on facial nerve regeneration, being therefore a useful technique to stimulate axonal regeneration process.
Kılıç, Burcu; Erşen, Ezel; Demirkaya, Ahmet; Kara, H Volkan; Alizade, Nurlan; İşcan, Mehlika; Kaynak, Kamil; Turna, Akif
2017-09-01
Postoperative air leak is a common complication seen after pulmonary resection. It is a significant reason of morbidity and also leads to greater hospital cost owing to prolonged length of stay. The purpose of this study is to compare homologous sealant with autologous one to prevent air leak following pulmonary resection. A total of 57 patients aged between 20 and 79 (mean age: 54.36) who underwent pulmonary resection other than pneumonectomy (lobar or sublobar resections) were analyzed. There were 47 males (83%) and 10 females (17%). Patients who intraoperatively had air leaks were randomized to receive homologous (Tisseel; n=28) or autologous (Vivostat; n=29) fibrin sealant. Differences among groups in terms of air leak, prolonged air leak, hospital stay, amount of air leak were analyzed. Indications for surgery were primary lung cancer in 42 patients (71.9%), secondary malignancy in 5 patients (8.8%), and benign disease in 10 patients (17.5%). Lobectomy was performed in 40 patients (70.2%), whereas 17 patients (29.8%) had wedge resection. Thirteen (46.4%) patients developed complications in patients receiving homologous sealant while 11 (38.0%) patients had complication in autologous sealant group (P=0.711). Median duration of air leak was 3 days in two groups. Time to intercostal drain removal was 3.39 and 3.38 days in homologous and autologous sealant group respectively (P=0.978). Mean hospital stay was 5.5 days in patients receiving homologous sealant whereas it was 5.0 days in patients who had autologous agent (P=0.140). There were no significant differences between groups in terms of measured maximum air leak (P=0.823) and mean air leak (P=0.186). There was no significant difference in the incidence of complications between two groups (P=0.711). Autologous and heterologous fibrin sealants are safe and acts similarly in terms of air leak and hospital stay in patients who had resectional surgery.
Erşen, Ezel; Demirkaya, Ahmet; Kara, H. Volkan; Alizade, Nurlan; İşcan, Mehlika; Kaynak, Kamil; Turna, Akif
2017-01-01
Background Postoperative air leak is a common complication seen after pulmonary resection. It is a significant reason of morbidity and also leads to greater hospital cost owing to prolonged length of stay. The purpose of this study is to compare homologous sealant with autologous one to prevent air leak following pulmonary resection. Methods A total of 57 patients aged between 20 and 79 (mean age: 54.36) who underwent pulmonary resection other than pneumonectomy (lobar or sublobar resections) were analyzed. There were 47 males (83%) and 10 females (17%). Patients who intraoperatively had air leaks were randomized to receive homologous (Tisseel; n=28) or autologous (Vivostat; n=29) fibrin sealant. Differences among groups in terms of air leak, prolonged air leak, hospital stay, amount of air leak were analyzed. Results Indications for surgery were primary lung cancer in 42 patients (71.9%), secondary malignancy in 5 patients (8.8%), and benign disease in 10 patients (17.5%). Lobectomy was performed in 40 patients (70.2%), whereas 17 patients (29.8%) had wedge resection. Thirteen (46.4%) patients developed complications in patients receiving homologous sealant while 11 (38.0%) patients had complication in autologous sealant group (P=0.711). Median duration of air leak was 3 days in two groups. Time to intercostal drain removal was 3.39 and 3.38 days in homologous and autologous sealant group respectively (P=0.978). Mean hospital stay was 5.5 days in patients receiving homologous sealant whereas it was 5.0 days in patients who had autologous agent (P=0.140). There were no significant differences between groups in terms of measured maximum air leak (P=0.823) and mean air leak (P=0.186). There was no significant difference in the incidence of complications between two groups (P=0.711). Conclusions Autologous and heterologous fibrin sealants are safe and acts similarly in terms of air leak and hospital stay in patients who had resectional surgery. PMID:29221263
Fibrin sealants: surgical hemostat, sealant and adhesive.
Mandell, Samuel P; Gibran, Nicole S
2014-06-01
Fibrin sealants (FS) have been approved for use in the United States since 1998. Since approval, they have been used in a wide variety of clinical settings and new products continue to be introduced. This review covers the literature supporting the USA FDA-approved indications for FS products produced by Baxter Corp. Literature review of PubMed, the Cochrane Library, FDA approval documents and product websites yielded information contained in this article. Mechanism of action, efficacy and safety of these products are covered. FS are generally safe, popular and are used for a wide variety of off-label indications. Their use appears to be expanding rapidly. For many uses, including approved ones, large well-controlled trials are still needed. Additionally, cost-effectiveness data for these products would be a great benefit in guiding their future use.
A highly adhesive and naturally derived sealant.
Assmann, Alexander; Vegh, Andrea; Ghasemi-Rad, Mohammad; Bagherifard, Sara; Cheng, George; Sani, Ehsan Shirzaei; Ruiz-Esparza, Guillermo U; Noshadi, Iman; Lassaletta, Antonio D; Gangadharan, Sidhu; Tamayol, Ali; Khademhosseini, Ali; Annabi, Nasim
2017-09-01
Conventional surgical techniques to seal and repair defects in highly stressed elastic tissues are insufficient. Therefore, this study aimed to engineer an inexpensive, highly adhesive, biocompatible, and biodegradable sealant based on a modified and naturally derived biopolymer, gelatin methacryloyl (GelMA). We tuned the degree of gelatin modification, prepolymer concentration, photoinitiator concentration, and crosslinking conditions to optimize the physical properties and adhesion of the photocrosslinked GelMA sealants. Following ASTM standard tests that target wound closure strength, shear resistance, and burst pressure, GelMA sealant was shown to exhibit adhesive properties that were superior to clinically used fibrin- and poly(ethylene glycol)-based glues. Chronic in vivo experiments in small as well as translational large animal models proved GelMA to effectively seal large lung leakages without the need for sutures or staples, presenting improved performance as compared to fibrin glue, poly(ethylene glycol) glue and sutures only. Furthermore, high biocompatibility of GelMA sealant was observed, as evidenced by a low inflammatory host response and fast in vivo degradation while allowing for adequate wound healing at the same time. Combining these results with the low costs, ease of synthesis and application of the material, GelMA sealant is envisioned to be commercialized not only as a sealant to stop air leakages, but also as a biocompatible and biodegradable hydrogel to support lung tissue regeneration. Copyright © 2017 Elsevier Ltd. All rights reserved.
A case series of anophthalmic socket cysts excised utilising fibrin sealant.
Wong, Yun; Clarke, Lucy; Lau, Gordon
2017-10-23
Anophthalmic socket cysts are challenging to remove and incomplete excision has been shown to increase the risk of recurrence. This case series describes a novel technique utilising the fibrin sealant Tisseel (Baxter AG, Vienna, Austria) to retain the socket cyst integrity during surgical removal to facilitate its complete excision. Five patients were included and followed up for a minimum of 1 year, and there were no signs of recurrence in any of the cases. The surgical technique is described and illustrated. This technique is a safe way of simplifying challenging socket cyst surgery.
Ishii, Keiichi; Kawashima, Hideki; Hayama, Takuma; Mayabashira, Sumika; Oka, Shiro; Sugimoto, Toshikado
2011-11-01
Various hemostatic agents have been used quite effectively for hemostasis, as well as for providing effective adhesion during laparoscopic partial nephrectomies. In this study, we investigated the adhesiveness to the renal tissue of some sheet-type hemostatic agents used in combination with a liquid fibrin sealant. In Experiment A, component solutions of the fibrin glue (liquid fibrin sealant) were dripped onto a kite string placed annularly on a porcine kidney slice. Then, one of the sheet-type hemostats--namely, the collagen, gelatin, or cellulose hemostat--was placed on the slices, and a string scale was used to measure the force needed to pull the string apart vertically from the kidney slice. Twelve slices were used for each group, and the weight data were analyzed statistically. The tissue adhering to each sheet-type hemostatic agent was fixed in formalin and sliced and then examined by light microscopy after hematoxylin and eosin staining. In Experiment B, the solutions were dripped onto the sheet-type hemostatic agent placed first on the slice, and the force needed for pulling apart the hemostat sheet from the slice was similarly examined. The combination of fibrin glue plus a collagen hemostat was clearly superior in Experiment A, but the hemostat and renal tissue could be pulled apart more easily in Experiment B. These results showed that fibrin glue could not exert its expected adhesive effect unless it is used in combination with another hemostatic agent or is directly applied to renal tissue. It is important to obtain further comparative data among agents and select the appropriate agents, taking into consideration the type of surgery.
Yin, Way; Pauza, Kevin; Olan, Wayne J; Doerzbacher, Jeff F; Thorne, Kevin J
2014-01-01
Assess the safety and efficacy of intradiscal fibrin sealant in adults with chronic discogenic low back pain. Prospective, nonrandomized Food and Drug Administration approved pilot study. Three centers in the United States. Fifteen adults with chronic, single, or contiguous two-level lumbar discogenic pain confirmed through meticulous provocation discography. Volume- and pressure-controlled intradiscal delivery of BIOSTAT BIOLOGX(®) Fibrin Sealant with the Biostat(®) Delivery Device into symptomatic lumbar disc(s). Assessments were performed at baseline, 72 hours, and 1, 4, 13, 26, 52, and 104 weeks following intervention. Potential adverse events were evaluated with serial assessment of neurological status, radiographic, and magnetic resonance imaging (MRI). Efficacy measures included serial assessments of low back pain visual analog scale (VAS) measurements and the Roland-Morris Disability Questionnaire (RMDQ). Safety neurological assessments, X-ray, and MRI showed no significant changes. Adverse events were reported in nine subjects. Two instances of low back muscle spasm and one case of discitis were the only events considered related to the procedure or product. Mean low back pain VAS scores (mm) decreased from 72.4 (95% confidence interval 64.6-80.3) at baseline to 31.7 (17.4-46.1), 35.4 (17.7-53.1), and 33.0 (16.3-49.6); mean RMDQ score improved from 15.2 (12.7-17.7) at baseline to 8.9 (5.3-12.5), 6.2 (3.4-9.1), and 5.6 (2.9-8.4) at 26, 52, and 104 weeks, respectively. Intradiscal injection of BIOSTAT BIOLOGX Fibrin Sealant with the Biostat Delivery Device appears safe and may improve pain and function in selected patients with discogenic pain. Wiley Periodicals, Inc.
Langrehr, J M; Schmidt, S C; Neuhaus, P
2005-08-01
Laparoscopic inguinal hernia repair offers more rapid recovery and less pain than with the traditional open approach. However, injury to the nerves of the lumbar plexus with subsequent chronic pain or neuralgia has a reported incidence of 2% during laparoscopic hernia repair, particularly when the transabdominal preperitoneal technique (TAPP) is used. These complications are inherent to the use of staples for fixation of the mesh. To avoid nerve irritation, we considered the use of fibrin sealant for the fixation of the mesh instead of staples. The aim of this study was to evaluate this technique and to compare the short-term follow-up of these patients with patients who underwent the staple repair technique. This is the first reported use of fibrin sealant in laparoscopic TAPP hernia repair. Between September and November 2004, we performed 17 consecutive laparoscopic hernia repairs (TAPP) in 14 patients (3 bilateral hernias) with primary hernias. The prosthetic mesh was fixed (10 x 15 cm) with 1 ml fibrin. The fibrin was applied using a special laparoscopic applicator. The peritoneum was closed with absorbable sutures. The postoperative course of these patients was compared with a cohort of matched patients who received the traditional staple fixation of the prosthetic mesh. Patients were evaluated at a median follow-up of 10.4 months (3.8-16.0 months). All patients underwent postoperative physical examinations. No recurrent hernia was found. There were 2 seromas and one hematoma in the stapled group. In the stapled group, one patient had pain in the area of the lateral femoral cutaneous nerve. There was no postoperative complication in the non-stapled group. Fibrin fixation of the mesh during laparoscopic transabdominal preperitoneal inguinal hernia repair is feasible without higher risk of recurrences. In addition the fibrin fixation method may decrease postoperative neuralgia and reduce the incidence of postoperative seromas and hematomas.
[Bond strengths of absorbable polylactic acid root canal post with three different adhesives].
Pan, Hui; Cheng, Can; Hu, Jia; Liu, He; Sun, Zhi-hui
2015-12-18
To find absorbable adhesives with suitable bonding properties for the absorbable polylactic acid root canal post. To test and compare the bond strengths of absorbable polylactic acid root canal post with three different adhesives. The absorbable polylactic acid root canal posts were used to restore the extracted teeth, using 3 different adhesives: cyanoacrylates, fibrin sealant and glass ionomer cement. The teeth were prepared into slices for micro-push-out test. The bond strength was statistically analyzed using ANOVA. The specimens were examined using microscope and the failure mode was divided into four categories: cohesive failure between absorbable polylactic acid root canal posts and adhesives, cohesive failure between dentin and adhesives, failure within the adhesives and failure within the absorbable polylactic acid root canal posts. The bond strength of cyanoacrylates [(16.83 ± 6.97) MPa] and glass ionomer cement [(12.10 ± 5.09) MPa] were significantly higher than fibrin sealant [(1.17 ± 0.50) MPa], P<0.001. There was no significant difference between cyanoacrylates and glass ionomer cement (P=0.156). In the group of cyanoacrylates, the cohesive failure between the absorbable polylactic acid root canal posts and the adhesives was 25.0%, the cohesive failure between the dentin and the adhesives was 16.7%, the failure within the adhesives was 33.3%, and the failure within the absorbable polylactic acid root canal posts was 25.0%. In the group of fibrin sealant, the cohesive failure between the absorbable polylactic acid root canal posts and the adhesives was 66.7%, the cohesive failure between the dentin and the adhesives was 22.2%, the failure within the adhesives was 11.1%. In the group of glass ionomer cement, the cohesive failure between the absorbable polylactic acid root canal posts and the adhesives was 87.5%, the failure within the adhesives was 12.5%. The major failure mode in fibrin sealant and glass ionomer cement was the cohesive failure between the absorbable polylactic acid root canal posts and the adhesives. No major failure modes were found in the group of cyanoacrylates. The bond strength of fibrin sealant is low, which cannot meet the requirement of clinical use. The bond strengths of cyanoacrylates and glass ionomer cement are suitable for clinical use. The cyanoacrylates are a kind of absorbable adhesive which has suitable bonding properties for the absorbable polylactic acid root canal post.
Painless treatment of hydrocele: EMLA cream anaesthesia and fibrin adhesive sclerotherapy.
Cecchi, M; Sepich, C A; Pagni, G; Ippolito, C; Minervini, R; Fiorentini, L
1997-01-01
Sclerotherapy for hydroceles was performed in 18 patients. Cutaneous anaesthesia was induced with an anaesthetic cream (lidocaine and prilocaine, EMLA cream) and a fibrin sealant (Tissucol) was injected into the sac after fluid aspiration. Patients experienced no pain during needle insertion and sclerosant procedure; 2 recurrences were observed during follow-up. EMLA cream anaesthesia and fibrin adhesive sclerotherapy represent a useful alternative to surgical treatment of hydroceles.
Briquez, Priscilla S; Lorentz, Kristen M; Larsson, Hans M; Frey, Peter; Hubbell, Jeffrey A
2017-08-01
Aprotinin is a broad-spectrum serine protease inhibitor used in the clinic as an anti-fibrinolytic agent in fibrin-based tissue sealants. However, upon re-exposure, some patients suffer from hypersensitivity immune reactions likely related to the bovine origin of aprotinin. Here, we aimed to develop a human-derived substitute to aprotinin. Based on sequence homology analyses, we identified the Kunitz-type protease inhibitor (KPI) domain of human amyloid-β A4 precursor protein as being a potential candidate. While KPI has a lower intrinsic anti-fibrinolytic activity than aprotinin, we reasoned that its efficacy is additionally limited by its fast release from fibrin material, just as aprotinin's is. Thus, we engineered KPI variants for controlled retention in fibrin biomaterials, using either covalent binding through incorporation of a substrate for the coagulation transglutaminase Factor XIIIa or through engineering of extracellular matrix protein super-affinity domains for sequestration into fibrin. We showed that both engineered KPI variants significantly slowed plasmin-mediated fibrinolysis in vitro, outperforming aprotinin. In vivo, our best engineered KPI variant (incorporating the transglutaminase substrate) extended fibrin matrix longevity by 50%, at a dose at which aprotinin did not show efficacy, thus qualifying it as a competitive substitute of aprotinin in fibrin sealants. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Autologous fibrin glue: the last step in operative hemostasis.
Tawes, R L; Sydorak, G R; DuVall, T B
1994-08-01
Fibrin glue may be the perfect hemostatic agent for operative use as it seals in minutes, has no tissue toxicity, reabsorbs, and promotes local tissue growth and repair. Use in the United States has been limited because of lack of Food and Drug Administration approval of the commercial homologous products, lack of a concentrated source of fibrinogen, and because of the potential for viral transmission, particularly hepatitis, with pooled homologous plasma and cryoprecipitate-based methods. Autologous fibrin glue (AFG) obviates these problems. During the past year, we obtained AFG through the same routine predonation procedure as with red blood cells before major elective surgery. Intraoperatively, we made AFG from the platelet-rich plasma derived from the Plasma-Saver. Our experience has been with 36 patients undergoing aortic, thoracoabdominal, and thoracic surgery, as well as patch graft angioplasty cases. Fibrin glue formation mimics the final stage in the coagulation cascade. The AFG from predonation acts more like an epoxy glue, while the AFG made during surgery is less viscous and acts more like a sealant because of the lesser concentration of fibrinogen in platelet-rich plasma. In emergencies, however, the intraoperative method is obviously the only choice available, and it is a useful adjunct to hemostasis at the end of the procedure. The technique will be described. This relatively new approach to hemostasis should gain popularity because it is easy and fairly inexpensive to produce, and because the patient's own blood is used.
Effectiveness of a new gelatin sealant system for dural closure.
Kawai, Hisashi; Nakagawa, Ichiro; Nishimura, Fumihiko; Motoyama, Yasushi; Park, Young-Su; Nakamura, Mitsutoshi; Nakase, Hiroyuki; Suzuki, Shuko; Ikada, Yoshito
2014-10-01
Watertight dural closure is imperative after neurosurgical procedures because inadequately treated leakage of cerebrospinal fluid (CSF) can have serious consequences. In this study, the authors test the use of a new gelatin glue as a dural sealant in in vitro and in vivo canine models of transdural CSF leakage. The in vitro model was sutured semicircles of canine dura mater and artificial dural substitute. The sutures were sealed with gelatin glue (n = 20), fibrin glue (n = 20), or a polyethylene glycol (PEG)-based hydrogel sealant (n = 20). Each sample was set in a device to measure water pressure, and pressure was increased until leakage occurred. Bonding strength was subjectively evaluated. The in vivo model was dogs who underwent dural excision and received either no sealant (control group; n = 5) or gelatin glue sealant (n = 5) before dural closure. Twenty-eight days post-surgery, the maximum intracranial pressure was measured at the cisterna magna using Valsalva maneuver and tissue adhesion was evaluated. The water pressure at which leakage occurred in the in vitro model was higher with gelatin glue (76·5 ± 39·8 mmHg) than with fibrin glue (38·3 ± 27·4 mmHg, P < 0·001) or the PEG-based hydrogel sealant (46·3 ± 20·9 mmHg, P = 0·007). Bonding strength was higher for the gelatin glue than fibrin glue (P < 0·001) or PEG-based hydrogel sealant (P = 0·001). The maximum intracranial pressure in the in vivo model was higher for the gelatin glue group (59·0 ± 2·2 mmHg) than the control group (13·8 ± 4·0 mmHg, P < 0·001). Tissue adhesion was lower for the gelatin glue group than the control group (P = 0·005). The new gelatin glue provides an effective watertight closure when used as an adjunct to sutured dural repair.
Shinya, Noriko; Oka, Shirou; Miyabashira, Sumika; Kaetsu, Hiroshi; Uchida, Takanori; Sueyoshi, Masuo; Takase, Kozo; Akuzawa, Masao; Miyamoto, Atsushi; Shigaki, Takamichi
2009-01-01
Although fibrin sealant (FS) has an advantage of high biocompatibility, its adhesive force and sealing effect have been generally considered to be inadequate. In the present study, a high adhesive force and sealing effect were obtained by first rubbing fibrinogen solution into the target tissue, attaching polyglycolic acid (PGA) felt to the treated area, and finally spraying it with FS. This method was compared with three conventional FS application methods and a method using fibrin glue-coated collagen fleece. The adhesive force resulting from the present method was 12 times higher than that for the sequential application method, 4.5 times higher than the spray method, 2.5 times higher than the rubbing and spray method, and 2.2 times higher than the use of fibrin glue-coated collagen fleece. The high adhesive force of FS with PGA felt seemed to be due the high fibrin content of the fibrin gel (FG). Light and electron microscopic observations suggested that the formation of FG in closer contact with the muscle fibers was a factor contributing to this superior adhesive force. Comparison of the sealing effect of the present method with other methods using various biomaterials in combination with FS showed that the sealing effect of FS with PGA felt was 1.4 times higher that of polyglactin 910, 1.8 times that of polytetrafluoroethylene, and 6.7 times that of oxidized regenerated cellulose.
Early clinical outcomes following laparoscopic inguinal hernia repair.
Tolver, Mette Astrup
2013-07-01
Laparoscopic inguinal hernia repair (TAPP) has gained increasing popularity because of less post-operative pain and a shorter duration of convalescence compared with open hernia repair technique (Lichtenstein). However, investigation of duration of convalescence with non-restrictive recommendations, and a procedure-specific characterization of the early clinical outcomes after TAPP was lacking. Furthermore, optimization of the post-operative period with fibrin sealant versus tacks for fixation of mesh, and the glucocorticoid dexamethasone versus placebo needed to be investigated in randomized clinical trials. The objective of this PhD thesis was to characterize the early clinical outcomes after TAPP and optimize the post-operative period. The four studies included in this thesis have investigated duration of convalescence and procedure-specific post-operative pain and other early clinical outcomes after TAPP. Furthermore, it has been shown that fibrin sealant can improve the early post-operative period compared with tacks, while dexamethasone showed no advantages apart from reduced use of antiemetics compared with placebo. Based on these findings, and the existing knowledge, 3-5 days of convalescence should be expected when 1 day of convalescence is recommended and future studies should focus on reducing intraabdominal pain after TAPP. Fibrin sealant can optimize the early clinical outcomes but the risk of hernia recurrence and chronic pain needs to be evaluated. Dexamethasone should be investigated in higher doses.
Roura, Santiago; Soler-Botija, Carolina; Bagó, Juli R; Llucià-Valldeperas, Aida; Férnandez, Marco A; Gálvez-Montón, Carolina; Prat-Vidal, Cristina; Perea-Gil, Isaac; Blanco, Jerónimo; Bayes-Genis, Antoni
2015-08-01
Considerable research has been dedicated to restoring myocardial cell slippage and limiting ventricular remodeling after myocardial infarction (MI). We examined the ability of a three-dimensional (3D) engineered fibrin patch filled with human umbilical cord blood-derived mesenchymal stem cells (UCBMSCs) to induce recovery of cardiac function after MI. The UCBMSCs were modified to coexpress luciferase and fluorescent protein reporters, mixed with fibrin, and applied as an adhesive, viable construct (fibrin-cell patch) over the infarcted myocardium in mice (MI-UCBMSC group). The patch adhered well to the heart. Noninvasive bioluminescence imaging demonstrated early proliferation and differentiation of UCBMSCs within the construct in the postinfarct mice in the MI-UCBMSC group. The implanted cells also participated in the formation of new, functional microvasculature that connected the fibrin-cell patch to both the subjacent myocardial tissue and the host circulatory system. As revealed by echocardiography, the left ventricular ejection fraction and fractional shortening at sacrifice were improved in MI-UCBMSC mice and were markedly reduced in mice treated with fibrin alone and untreated postinfarction controls. In conclusion, a 3D engineered fibrin patch composed of UCBMSCs attenuated infarct-derived cardiac dysfunction when transplanted locally over a myocardial wound. ©AlphaMed Press.
Seo, Bommie F; Kang, In Sook; Jeong, Yeon Jin; Moon, Suk Ho
2014-06-01
The Morel-Lavallée lesion is a collection of serous fluid that develops after closed degloving injuries and after surgical procedures particularly in the pelvis and abdomen. It is a persistent seroma and is usually resistant to conservative methods of treatment such as percutaneous drainage and compression. Various methods of curative treatment have been reported in the literature, such as application of fibrin sealant, doxycycline, or alcohol sclerodhesis. We present a case of a huge recurrent Morel-Lavallée lesion in the lower back and buttock region that was treated with quilting sutures, fibrin sealant, and compression, with a review of the literature. © The Author(s) 2014.
Compression-induced structural and mechanical changes of fibrin-collagen composites.
Kim, O V; Litvinov, R I; Chen, J; Chen, D Z; Weisel, J W; Alber, M S
2017-07-01
Fibrin and collagen as well as their combinations play an important biological role in tissue regeneration and are widely employed in surgery as fleeces or sealants and in bioengineering as tissue scaffolds. Earlier studies demonstrated that fibrin-collagen composite networks displayed improved tensile mechanical properties compared to the isolated protein matrices. Unlike previous studies, here unconfined compression was applied to a fibrin-collagen filamentous polymer composite matrix to study its structural and mechanical responses to compressive deformation. Combining collagen with fibrin resulted in formation of a composite hydrogel exhibiting synergistic mechanical properties compared to the isolated fibrin and collagen matrices. Specifically, the composite matrix revealed a one order of magnitude increase in the shear storage modulus at compressive strains>0.8 in response to compression compared to the mechanical features of individual components. These material enhancements were attributed to the observed structural alterations, such as network density changes, an increase in connectivity along with criss-crossing, and bundling of fibers. In addition, the compressed composite collagen/fibrin networks revealed a non-linear transformation of their viscoelastic properties with softening and stiffening regimes. These transitions were shown to depend on protein concentrations. Namely, a decrease in protein content drastically affected the mechanical response of the networks to compression by shifting the onset of stiffening to higher degrees of compression. Since both natural and artificially composed extracellular matrices experience compression in various (patho)physiological conditions, our results provide new insights into the structural biomechanics of the polymeric composite matrix that can help to create fibrin-collagen sealants, sponges, and tissue scaffolds with tunable and predictable mechanical properties. Copyright © 2016 Elsevier B.V. All rights reserved.
Moritz, Martina; Pfeifer, Sabine; Balmayor, Elizabeth R; Mittermayr, Rainer; Wolbank, Susanne; Redl, Heinz; van Griensven, Martijn
2017-07-01
Skeletal ischaemia-reperfusion (I-R) injury may influence patient outcome after severe vascular trauma or clamping of major vessels. The aim of this study was to observe whether locally applied vascular endothelial growth factor (VEGF) in fibrin could induce the expression of VEGF-receptor-2 (VEGFR-2) and improve the outcome after I-R injury. Transgenic mice expressing VEGFR-2 promoter-controlled luciferase were used for the assessment of VEGFR-2 expression. Ischaemia was induced for 2 h by a tension-controlled tourniquet to the hind limb, followed by 24 h of reperfusion. The animals were locally injected subcutaneously with fibrin sealant containing 20 or 200 ng VEGF; control animals received no treatment or fibrin sealant application. In vivo VEGFR-2 expression was quantified upon administration of luciferin at several observation times. For oedema and inflammation quantification, wet:dry ratio measurements and a myeloperoxidase assay of the muscle tissue were performed. Laser Doppler imaging showed that ischaemia was present and that the blood flow had returned to baseline levels after 24 h of reperfusion. VEGFR-2 expression levels in the fibrin + 200 ng VEGF were significantly higher than in all other groups. Granulocyte infiltration was reduced in both treatment groups, as well as reduced oedema formation. These results showed that VEGF released from fibrin had a positive effect on early I-R outcome in a mouse model, possibly via VEGFR-2. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Evolution of hemostatic agents in surgical practice
Sundaram, Chandru P.; Keenan, Alison C.
2010-01-01
Objective: Topical hemostatic agents are used in a wide variety of surgical settings, and the evolution of this class of surgical tools is an interesting topic. We reviewed and outlined the historical progress of topical hemostats into present day surgery and urology, and highlight opportunities for future research. Materials and Methods: A MEDLINE search of all available literature concerning several classes of topical hemostatic agents was performed. Fibrins sealants, Gelatin sponge hemostatics, cyanoacrylate adhesives, oxidized regenerated cellulose, and microfibrillar collagen were included. References were chosen from a broad range of surgical literature. Results: Topical hemostatic agents have historically taken advantage of a wide variety of mechanisms for hemostasis. Fibrin sealants have a rich history and large potential for further applications. Gelatin sponge hemostatics have been widely used since their introduction, but have changed little. Cyanoacrylate adhesives have a unique mechanism and opportunity for novel applications of existing products. Oxidized cellulose was original in the use of plant-based components. Microfibrillar collagen hemostats have evolved to a wide variety of formats. Conclusions: A review of the evolution of topical hemostatic agents highlights opportunities for potential novel research. Fibrin sealants may have the most opportunity for advancement, and understanding the history of these products is useful. With the drive in urology for minimally invasive surgical techniques, adaptation of topical hemostatic agents to this surgical approach would be valuable and offers an opportunity for novel contributions. PMID:21116358
Rosso, Marcelie Priscila de Oliveira; Rosa Júnior, Geraldo Marco; Buchaim, Daniela Vieira; German, Iris Jasmin Santos; Pomini, Karina Torres; de Souza, Rafael Gomes; Pereira, Mizael; Favaretto Júnior, Idvaldo Aparecido; Bueno, Cleuber Rodrigo de Souza; Gonçalves, Jéssica Barbosa de Oliveira; Ferreira Júnior, Rui Seabra; Barraviera, Benedito; Andreo, Jesus Carlos; Buchaim, Rogério Leone
2017-10-01
This research evaluated the influence of Photobiomodulation Therapy (PBMT) on lesions of the facial nerve repaired with the end-to-side technique or coaptation with a new heterologous fibrin sealant. Thirty-two Wistar rats were separated into 5 groups: Control group (CG), where the buccal branch of the facial nerve was collected; Experimental Suture Group (ESG) and Experimental Fibrin Group (EFG), in which the buccal branch was end-to-side sutured to the zygomatic branch on the right side of the face or coaptated with fibrin sealant on the left side; Experimental Suture Laser Group (ESLG) and Experimental Fibrin Laser Group (EFLG), in which the same procedures were performed as the ESG and EFG, associated with PBMT (wavelength of 830nm, energy density 6.2J/cm 2 , power output 30mW, beam area of 0.116cm 2 , power density 0.26W/cm 2 , total energy per session 2.16J, cumulative dose of 34.56J). The laser was applied for 24s/site at 3 points on the skin's surface, for a total application time of 72s, performed immediately after surgery and 3 times a week for 5weeks. A statistically significant difference was observed in the fiber nerve area between the EFG and EFLG (57.49±3.13 and 62.52±3.56μm 2 , respectively). For the area of the axon, fiber diameter, axon diameter, myelin sheath area and myelin sheath thickness no statistically significant differences were found (p<0.05). The functional recovery of whisker movement occurred faster in the ESLG and EFLG, which were associated with PBMT, with results closer to the CG. Therefore, PBMT accelerated morphological and functional nerve repair in both techniques. Copyright © 2017. Published by Elsevier B.V.
Whyte, Graeme P; McGee, Alan; Jazrawi, Laith; Meislin, Robert
2016-05-01
To evaluate the fixation integrity at time zero of a type I/III collagen patch secured to a chondral defect in the porcine knee using methods typically employed in autologous chondrocyte implantation (ACI) and matrix-assisted chondrocyte implantation. Twenty-four porcine knee specimens underwent a medial parapatellar arthrotomy. A prefabricated template was used to create cartilage defects of 2 cm(2) in the medial femoral condyle. A size-matched collagen patch was fashioned. Four methods of fixation to the chondral defect were analyzed: group 1-saline, group 2-fibrin glue around the periphery of the patch, group 3-fibrin glue applied to the base of the defect and around the periphery of the patch, group 4-6-0 vicryl suture and fibrin glue around the periphery of the patch. Collagen patch fixation was assessed at intervals of 60, 300, 600, 900, and 1,200 cycles from full extension to 90° of flexion, performed manually without application of axial force. Patch fixation was evaluated by 2 independent observers using a customized scoring scale. Mean peripheral detachment of the patch and chondral defect uncovering remained less than 25% for all groups. Area of defect uncovering was significantly increased in group 2 compared with group 4 after 900 and 1,200 cycles (P = .0014 and P = .0025, respectively). Fibrin glue applied to the base of the defect, or suturing of the patch, reduced deformation significantly after 900 cycles. Suture increases the stability of fixation of a type I/III collagen patch to a chondral defect better than fibrin glue alone in the porcine knee after repetitive cycling, with respect to patch detachment and chondral defect uncovering. Application of fibrin glue to the base of the defect, or securing the patch with suture, decreases collagen patch deformation. In cases where minimally invasive techniques do not allow suture fixation of the collagen patch, scaffold fixation may be compromised during articular motion protocols typically used after second- and third-generation ACI procedures. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Kroez, Monika; Lang, Wiegand; Dickneite, Gerhard
2005-01-01
The objective of this study was to investigate the degradation kinetics of the fibrin sealant (FS) Beriplast P in an experimental liver surgery model in rabbits. A partial liver resection was performed in 21 rabbits, and the wound area covered with Beriplast P to ensure hemostasis. Wound healing of the resection sites was evaluated morphologically over 11 weeks. Degradation of the FS was evaluated by measuring the thickness of the remaining fibrin layer. Plasma samples were analyzed for antibodies against fibrinogen, albumin, thrombin, fibrin, and factor XIII. No postoperative hemorrhage was observed, indicating successful hemostasis throughout. The FS was degraded with a half-life of about 25 days postapplication and was completely replaced by granulation tissue within 9 weeks. The FS degradation and tissue development followed the general stages of wound healing: inflammation and resorption, proliferation, organization and production of collagen, maturation, and scarring. An immune reaction was elicited against the main four human proteins of the FS. The antibody titers peaked on day 14, with a gradual decrease thereafter. We conclude that the FS accomplished hemostasis, facilitated healing in accordance with natural processes, and was completely degraded over time. In humans, the reduced immunogenicity of the FS would potentially increase its degradation half-life.
Gubitosi, A; Moccia, G; Malinconico, F A; Docimo, G; Ruggiero, R; Iside, G; Avenia, N; Docimo, L; Foroni, F; Gilio, F; Sparavigna, L; Agresti, M
2009-01-01
The authors, on the basis of a long clinical experience with human fibrin glue in general surgery, compared two different extracellular matrix (collagen), Surgisis and TissueDura, with human fibrin glue, applied during the operation, and sometimes in postoperative, to obtain the healing of perianal fistulas. The collagenic extracellular matrix provides, according to the rationale suggested, an optimal three-dimensional structure for the fibroblastic implant and neoangiogenesis, hence for the fistula "fibrotizzation" and closure. The encouraging results for transphincteric fistulas and a simple and easy technique push to researchers on samples statistically significant.
Li, Jun; Zhu, Kai; Yang, Shan; Wang, Yulin; Guo, Changfa; Yin, Kanhua; Wang, Chunsheng; Lai, Hao
2015-05-01
Bone marrow mesenchymal stem cells (BMSCs), tissue-engineered cardiac patch, and therapeutic gene have all been proposed as promising therapy strategies for cardiac repair after myocardial infarction. In our study, BMSCs were modified with insulin-like growth factor-1 (IGF-1) gene, loaded into a fibrin patch, and then transplanted into a porcine model of ischemia/reperfusion (I/R) myocardium injury. The results demonstrated that IGF-1 gene overexpression could promote proliferation of endothelial cells and cardiomyocyte-like differentiation of BMSCs in vitro. Four weeks after transplantation of fibrin patch loaded with gene-modified BMSCs, IGF-1 overexpression could successfully promote angiogenesis, inhibit remodeling, increase grafted cell survival and reduce apoptosis. In conclusion, the integrated strategy, which combined fibrin patch with IGF-1 gene modified BMSCs, could promote the histological cardiac repair for a clinically relevant porcine model of I/R myocardium injury. © 2015 by the Society for Experimental Biology and Medicine.
New generation tissue sealants and hemostatic agents: innovative urologic applications.
Traver, Michael A; Assimos, Dean G
2006-01-01
Control of blood loss during urologic surgery is paramount to the success of patient recovery. Hemostatic agents and tissue sealants are used routinely to prevent excess blood loss and in reconstruction during surgical repair. Some of the available products include thrombin sealant, fibrin glue, bovine serum/albumin/glutaraldehyde, and gelatin matrix. Each of these agents differs in mechanism, cost, and application. Complications can include allergic reactions or thromboembolism and the risk of contracting bovine spongiform encephalitis or hepatitis. Many new hemostatic agents are being developed and approved. The benefits and risks of use of these agents versus conventional treatment need to be considered on a case-by-case basis by the surgeon.
In vivo near infrared (NIRS) sensor attachment using fibrin bioadhesive
NASA Astrophysics Data System (ADS)
Macnab, Andrew; Pagano, Roberto; Kwon, Brian; Dumont, Guy; Shadgan, Babak
2018-02-01
Background: `Tisseel' (Baxter Healthcare, Deerfield, IL) is a fibrin-based sealant that is commonly used during spine surgery to augment dural repairs. We wish to intra-operatively secure a near infrared spectroscopy (NIRS) sensor to the dura in order to monitor the tissue hemodynamics of the underlying spinal cord. To determine if `Tisseel' sealant adversely attenuates NIR photon transmission. Methods: We investigated `Tisseel' in both an in vitro and in vivo paradigm. For in vitro testing, we used a 1 mm pathlength cuvette containing either air or `Tisseel' interposed between a NIR light source (760 and 850 nm) and a photodiode detector and compared transmittance. For in vivo testing, a continuous wave (760 and 850 nm) spatiallyresolved NIRS device was placed over the triceps muscle using either conventional skin apposition (overlying adhesive bandage) or bioadhesion with `Tisseel'. Raw optical data and tissue saturation index (TSI%) collected at rest were compared. Results: In-vitro NIR light absorption by `Tisseel' was very high, with transmittance reduced by 95% compared to air. In-vivo muscle TSI% values were 80% with conventional attachment and 20% using fibrin glue. Conclusion: The optical properties of `Tisseel' significantly attenuate NIR light during in-vitro transmittance and critically compromise photon transmission in-vivo.
Effects of a Fibrin Sealant on Skin Graft Tissue Adhesion in a Rodent Model.
Balceniuk, Mark D; Wingate, Nicholas A; Krein, Howard; Curry, Joseph; Cognetti, David; Heffelfiner, Ryan; Luginbuhl, Adam
2016-07-01
To establish a rodent model for skin grafting with fibrin glue and examine the effects of fibrin glue on the adhesive strength of skin grafts without bolsters. Animal cohort. Academic hospital laboratory. Three skin grafts were created using a pneumatic microtome on the dorsum of 12 rats. Rats were evenly divided into experimental (n = 6) and control (n = 6) groups. The experimental group received a thin layer of fibrin glue between the graft and wound bed, and the control group was secured with standard bolsters. Adherence strength of the skin graft was tested by measurement of force required to sheer the graft from the recipient wound. Adhesion strength measurements were taken on postoperative days (PODs) 1, 2, and 3. The experimental group required an average force of 719 g on POD1, 895 g on POD2, and 676 g on POD3, while the average force in the control group was 161 g on POD1, 257 g on POD2, and 267 g on POD3. On each of the 3 PODs, there was a significant difference in adherence strength between the experimental and control groups (P = .036, P = .029, P = .024). There is a significant difference in the adhesion strength of skin grafts to the wound bed in the early postoperative period of the 2 groups. In areas of high mobility, using the fibrin sealant can keep the graft immobile during the critical phases of early healing. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.
Hemostats, sealants, and adhesives: components of the surgical toolbox.
Spotnitz, William D; Burks, Sandra
2008-07-01
The surgical toolbox is expanding, and newer products are being developed to improve results. Reducing blood loss so that bloodless surgery can be performed may help minimize morbidity and length of stay. As patients, hospital administrators, and government regulators desire less invasive procedures, the surgical technical challenge is increasing. More operations are being performed through minimally invasive incisions with laparoscopic, endoscopic, and robotic approaches. In this setting, tools that can reduce bleeding by causing blood to clot, sealing vessels, or gluing tissues are gaining an increasing importance. Thus, hemostats, sealants, and adhesives are becoming a more important element of surgical practice. This review is designed to facilitate the reader's basic knowledge of these tools so that informed choices are made for controlling bleeding in specific clinical situations. Such information is useful for all members of the operative team. The team includes surgeons, anesthesiologists, residents, and nurses as well as hematologists and other medical specialists who may be involved in the perioperative care of surgical patients. An understanding of these therapeutic options may also be helpful to the transfusion service. In some cases, these materials may be stored in the blood bank, and their appropriate use may reduce demand for other transfusion components. The product classification used in this review includes hemostats as represented by product categories that include mechanical agents, active agents, flowables, and fibrin sealants; sealants as represented by fibrin sealants and polyethylene glycol hydrogels; and adhesives as represented by cyanoacrylates and albumin cross-linked with glutaraldehyde. Only those agents approved by the Food and Drug Administration (FDA) and presently available (February 2008) for sale in the United States are discussed in this review.
Fibrin matrices: The versatile therapeutic delivery systems.
Ahmad, Ejaj; Fatima, Munazza Tamkeen; Hoque, Mehboob; Owais, Mohammad; Saleemuddin, Mohammed
2015-11-01
Fibrin sealants, that have been employed for over a century by surgeons to stop post surgery bleeding, are finding novel applications in the controlled delivery of antibiotics and several other therapeutics. Fibrinogen can be easily purified from blood plasma and converted by thrombolysis to fibrin that undergoes spontaneous aggregation to form insoluble clot. During the gelling, fibrin can be formulated into films, clots, threads, microbeads, nanoconstructs and nanoparticles. Whole plasma clots in the form of beads and microparticles can also be prepared by activating endogenous thrombin, for possible drug delivery. Fibrin formulations offer remarkable scope for controlling the porosity as well as in vivo degradability and hence the release of the associated therapeutics. Binding/covalent-linking of therapeutics to the fibrin matrix, crosslinking of the matrix with bifunctional reagents and coentrapment of protease inhibitors have been successful in regulating both in vitro and in vivo release of the therapeutics. The release rates can also be remarkably lowered by preentrapment of therapeutics in insoluble particles like liposomes or by anchoring them to the matrix via molecules that bind them as well as fibrin. Copyright © 2015 Elsevier B.V. All rights reserved.
Smith, Caroline Mary; Jones, Abigail; Dass, Dipankar; Murthi, Govind; Lindley, Richard
2015-02-01
The use of fibrin sealant in the management of pilonidal sinus disease has not previously been described in children. We present our experience of primary pit excision and use of fibrin sealant (PEF) and compare outcomes with lateralising flap procedures (LFP). A single centre retrospective case note review of all children who had undergone a definitive procedure for pilonidal sinus from August 2006 to Dec 2013 was performed using data expressed as median (range) and compared using Fisher's exact test. P<0.05 was regarded as significant. Forty-one children were identified having undergone 49 procedures, with median age 15 (12-16 years) and follow up 32 (8-92) months. Groups were comparable for disease severity. Ten children underwent primary PEF and twenty-six LFP. Two children had recurrence following primary PEF and had repeat PEF which was curative. Overall recurrence rates following PEF procedure were comparable to LFP (17% vs 21%; P=1.0). There were no wound dehiscences in the PEF group and one wound infection. There was one wound dehiscence and one wound infection in the LFP group. Median operative time for PEF was lower than LFP (20 vs 60 min, P=0.001). 83% of PEF procedures were performed as day cases. One child was lost to follow up, and two children progressed to adult services. We recommend PEF in children with pilonidal sinus disease as primary treatment and for recurrence. PEF has comparable recurrence and wound infection rates to LFPs, is performed as day case, has shorter anaesthetic times, and the risk of wound dehiscence is avoided. Copyright © 2015 Elsevier Inc. All rights reserved.
Mussel-inspired hyperbranched poly(amino ester) polymer as strong wet tissue adhesive.
Zhang, Hong; Bré, Lígia P; Zhao, Tianyu; Zheng, Yu; Newland, Ben; Wang, Wenxin
2014-01-01
Current medical adhesives based on cyanoacrylates typically exhibit cellular toxicity. In contrast, fibrin adhesives are non-toxic but have poor adhesive properties. To overcome these drawbacks we designed a simple and scalable adhesive precursor inspired by marine mussel adhesion that functioned with strong adhesion in wet conditions and with low cytotoxicity. Dopamine, an-amine derivative of an amino acid abundantly present in mussel adhesive proteins, was co-polymerised with a tri-functional vinyl monomer, to form a hyperbranched poly(β-amino ester) polymer termed poly(dopamine-co-acrylate) (PDA). A variety of molecular weights and crosslinking methods were analysed using an ex vivo porcine skin model and an almost 4 fold increase in wet adhesion strength was observed compared to TISSEEL(®) fibrin sealant. With a fast curing time, degradable properties and low cytotoxicity, PDA is highly attractive for medical purposes and could have a broad impact on surgeries where surgical tissue adhesives, sealants, and haemostatic agents are used. Copyright © 2013 Elsevier Ltd. All rights reserved.
Usefulness of a New Gelatin Glue Sealant System for Dural Closure in a Rat Durotomy Model
KAWAI, Hisashi; NAKAGAWA, Ichiro; NISHIMURA, Fumihiko; MOTOYAMA, Yasushi; PARK, Young-Su; NAKAMURA, Mitsutoshi; NAKASE, Hiroyuki; SUZUKI, Shuko; IKADA, Yoshito
2014-01-01
Watertight dural closure is imperative after neurosurgical procedures, because inadequately treated leakage of cerebrospinal fluid (CSF) can have serious consequences. We used a rat durotomy model to test the usefulness of a new gelatin glue as a dural sealant in a rat model of transdural CSF leakage. All rats were randomly divided into one of the following three treatment groups: no application (control group: N = 18), application of fibrin glue (fibrin glue group: N = 18), and application of the new gelatin glue (new gelatin glue group: N = 18). The craniotomy side was re-opened, and CSF leakage was checked and recorded at 1, 7, and 28 days postoperatively. The new gelatin glue was adequate for stopping CSF leakage; no leakage was observed at postoperative days 1 or 7, and leakage was observed in only one rat at postoperative day 28. This result was statistically significant when compared to the control group (P = 0.002, P = 0.015, P = 0.015, respectively). The pathologic score of the new gelatin group was not different from that of the control or fibrin glue groups. We conclude that our new gelatin glue provides effective watertight closure 1, 7, and 28 days after operation in the rat durotomy model. PMID:25070015
Controlling air leaks using free pericardial fat pads as surgical sealant in pulmonary resection.
Ikeda, Takeshi; Sasaki, Masato; Yamada, Narihisa; Takamori, Atsushi; Tanabe, Sawaka; Okada, Akitoshi; Sakon, Kayo; Mizunaga, Tae; Koshiji, Takaaki
2015-04-01
This study evaluated the feasibility and efficacy of a new operative method for controlling intraoperative air leaks using free pericardial fat pads as a covering sealant in pulmonary resection. To manage air leaks that must be controlled in pulmonary resection at the first water sealing test, collected free pericardial fat was used as a covering sealant and sewn on by the suture closing the lesion. In cases of uncontrolled air leaks at the second sealing test, fibrin glue was used to fill the residual lesion between the fat and visceral pleura. Fifty-one eligible patients were enrolled in this study to evaluate the duration of postoperative air leaks and the condition of the implanted fat on chest computed tomography (CT) 6 months later. The mean duration of postoperative air leaks was 1.05 ± 1.84 days in the 39 cases that received the pericardial fat covering technique only and 2.66 ± 3.42 days in the 12 cases that received the pericardial fat covering technique combined with fibrin glue. Prolonged alveolar air leaks occurred in 1 case and 2 cases, respectively. No cases required conversion to conventional methods, and there were no further adverse events. On follow-up chest CT approximately 62.7% of obvious engrafted fat survived. Using free pericardial fat pads as a sealant to control air leaks in pulmonary resection is safe and has good feasibility and potent efficacy. This new method can be an innovative technique for preventing prolonged air leaks. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Fibrinogen inhibits fibroblast-mediated contraction of collagen
Nien, Yih-Dar; Han, Yuan-Ping; Tawil, Bill; Chan, Linda S.; Tuan, Tai-Lan; Garner, Warren L.
2008-01-01
Extracellular matrix changes in composition and organization as it transitions from the provisional matrix of the fibrin/platelet plug to collagen scar in healed wounds. The manner in which individual matrix proteins affect these activities is not well established. In this article we describe the interactions of two important extracellular matrix components, fibrin and collagen, using an in vitro model of wound contraction, the fibroblast-populated collagen lattice. We utilized different fibrinogen sources and measured tissue reorganization in floating and tensioned collagen lattices. Our results showed that both fibrin and fibrinogen decreased the contraction of fibroblast populated collagen lattices in a dose-dependent manner. Polymerization of fibrinogen to fibrin using thrombin had no effect on this inhibition. Further, there was no effect due to changes in protein concentration, alternate components of the fibrin sealant, or the enzymatic action of thrombin. These results suggest that the initial stability of the fibrin provisional matrix is due to the fibrin, because this protein appears to inhibit contraction of the matrix. This may be important in the early phases of wound healing when clot stability is vital for hemostasis. Later, as fibrin is replaced by collagen, wound contraction can occur. PMID:12950643
Romanos, G E; Strub, J R
1998-03-05
Fibrin sealants are very useful in different surgical fields. Fixation of free gingival grafts, root coverage procedures, and other techniques increasing connective tissue attachment may be associated with the application of Tissucol in periodontology. The aim of this study was to evaluate the influence of the fibrin sealant in the extracellular matrix, as well as alterations of the connective tissue matrix during wound-healing processes. In the back dermis of 15 Net male rats, Tissucol was implanted after intraperitoneal anesthesia. The implant material was placed in subcutaneous pockets (2 cm in length) which were sutured with interproximal sutures (test and control pockets). At 4, 7, 14, 21, and 28 days after surgery, biopsies of the healed and surrounding tissues were taken, frozen in liquid nitrogen, and examined histologically and immunohistochemically with antibodies against collagen types I, III, IV, V, VI, and VII. The findings showed thick and thin collagen type I and III fibers, respectively, with different orientations localized around the implant material. An increased amount of blood vessels and capillaries (their basement membranes containing collagen type IV) was observed during wound healing which may be associated with the implantation of the sealant. Collagen type V fibers were localized from the first days to the 4th postoperative week and, without any inflammatory reaction (according to histologic staining), formed a fibrillar extracellular matrix with high collagenase resistance. Collagen type VI showed a microfibrillar pattern of distribution, and collagen type VII was localized in the dermo epidermo junction and very deep in the connective tissue in the form of anchoring fibers (only in the test group) during the 4 postoperative weeks of healing. The data showed that Tissucol is a biocompatible component which cannot produce any extensive inflammatory reaction in the matrix. New blood vessel formation, an epithelial-connective tissue interface with high stability, as well as matrix alterations with high resistance in the proteolytic enzymes (i.e., collagenases) can be induced in the connective tissue after use of a fibrin sealant. All of these characteristics may be of great importance in connective tissue healing in periodontal surgical procedures.
Vivostat®: an autologous fibrin sealant as useful adjunct in endoscopic transnasal CSF-leak repair.
Tomazic, Peter Valentin; Edlinger, Stefan; Gellner, Verena; Koele, Wolfgang; Gerstenberger, Claus; Braun, Hannes; Mokry, Michael; Stammberger, Heinz
2015-06-01
The benefit of fibrin glue for reduction of postoperative CSF-leaks after endoscopic skull base surgery is not clearly evident in literature. However, its use is supposed to be beneficial in fixing grafting material. As of today there is no specific data available for otolaryngological procedures. A retrospective data analysis at a tertiary care referral center on 73 patients treated endoscopically transnasally for CSF-leaks at the ENT-department Graz between 2009 and 2012 was performed. Primary closure rate between conventional fibrin glue and autologous fibrin glue were analyzed. The Vivostat(®) system was used in 33 CSF-leak closures and in 40 cases conventional fibrin glue was used. Comparing the two methods the primary closure rate using the autologous Vivostat(®) system was 75.8 and 85.0 % with conventional fibrin glue. The secondary closure the rates were 90.9 % with Vivostat(®) 92.5 % with conventional fibrin glue. The Vivosat(®) system is a useful adjunct in endoscopic CSF-leak closure. Its advantages over conventional fibrin glue are its application system for fixation of grafting material particularly in underlay techniques. Despite this advantage it cannot replace grafting material or is a substitute for proper endoscopic closure which is reflected by the closure rates.
Cell culture in autologous fibrin scaffolds for applications in tissue engineering.
de la Puente, Pilar; Ludeña, Dolores
2014-03-10
In tissue engineering techniques, three-dimensional scaffolds are needed to adjust and guide cell growth and to allow tissue regeneration. The scaffold must be biocompatible, biodegradable and must benefit the interactions between cells and biomaterial. Some natural biomaterials such as fibrin provide a structure similar to the native extracellular matrix containing the cells. Fibrin was first used as a sealant based on pools of commercial fibrinogen. However, the high risk of viral transmission of these pools led to the development of techniques of viral inactivation and elimination and the use of autologous fibrins. In recent decades, fibrin has been used as a release system and three-dimensional scaffold for cell culture. Fibrin scaffolds have been widely used for the culture of different types of cells, and have found several applications in tissue engineering. The structure and development of scaffolds is a key point for cell culture because scaffolds of autologous fibrin offer an important alternative due to their low fibrinogen concentrations, which are more suitable for cell growth. With this review our aim is to follow methods of development, analyze the commercial and autologous fibrins available and assess the possible applications of cell culture in tissue engineering in these three-dimensional structures. Copyright © 2013 Elsevier Inc. All rights reserved.
Gruber-Blum, S; Brand, J; Keibl, C; Redl, H; Fortelny, R H; May, C; Petter-Puchner, A H
2015-08-01
Fibrin sealant (FS) is a safe and efficient fixation method in open intraperitoneal hernia repair. While favourable results have been achieved with hydrophilic meshes, hydrophobic (such as Omega fatty acid coated) meshes (OFM) have not been specifically assessed so far. Atrium C-qur lite(®) mesh was tested in rats in models of open onlay and intraperitoneal hernia repair. 44 meshes (2 × 2 cm) were implanted in 30 male Sprague-Dawley rats in open (n = 2 meshes per animal) and intraperitoneal technique (IPOM; n = 1 mesh per animal). Animals were randomised to four groups: onlay and IPOM sutured vs. sealed. Follow-up was 6 weeks, sutured groups serving as controls. Evaluation criteria were mesh dislocation, adhesions and foreign body reaction. FS provided a reliable fixation in onlay technique, whereas OFM meshes dislocated in the IPOM position when sealed only. FS mesh fixation was safe with OFM meshes in open onlay repair. Intraperitoneal placement of hydrophobic meshes requires additional fixation and cannot be achieved with FS alone.
Furuichi, Yoshihiro; Kasai, Yoshitaka; Takeuchi, Hirohito; Yoshimasu, Yuu; Kawai, Takashi; Sugimoto, Katsutoshi; Kobayashi, Yoshiyuki; Nakamura, Ikuo; Itoi, Takao
2017-08-01
A 58-year-old man with hepatitis B cirrhosis noticed black stools and underwent an endoscopy at a community hospital. The presence of esophageal varices (EVs) was confirmed, but the bleeding point was not found. He was referred to our institution and underwent a second endoscopy. Extensive white patches of esophageal candidiasis were visible on endoscopy by white-light imaging (WLI), but it was difficult to find the fibrin cap of the EVs. This was easier under narrow-band imaging (NBI), however, as the color turned red from absorption by hemoglobin adhered to it. We retrospectively measured the color differences (CD) between the fibrin cap and the surrounding mucosa 10 times using the CIE (L*a*b*) color space method. The median value of CD increased after NBI (13.9 → 43.0, p < 0.001), with increased visibility. However, the median CD between the white patch and surrounding mucosa decreased after NBI (44.8 → 30.3, p < 0.001). The fibrin cap was paler than the white patch of candidiasis, but the increased visibility of the fibrin cap by NBI enabled it to be found more easily. This is the first report of a case in which NBI was helpful in locating a fibrin cap of EVs.
What Is the Biological and Clinical Relevance of Fibrin?
Litvinov, Rustem I; Weisel, John W
2016-06-01
As our knowledge of the structure and functions of fibrinogen and fibrin has increased tremendously, several key findings have given some people a superficial impression that the biological and clinical significance of these clotting proteins may be less than earlier thought. Most strikingly, studies of fibrinogen knockout mice demonstrated that many of these mice survive to weaning and beyond, suggesting that fibrin(ogen) may not be entirely necessary. Humans with afibrinogenemia also survive. Furthermore, in recent years, the major emphasis in the treatment of arterial thrombosis has been on inhibition of platelets, rather than fibrin. In contrast to the initially apparent conclusions from these results, it has become increasingly clear that fibrin is essential for hemostasis; is a key factor in thrombosis; and plays an important biological role in infection, inflammation, immunology, and wound healing. In addition, fibrinogen replacement therapy has become a preferred, major treatment for severe bleeding in trauma and surgery. Finally, fibrin is a unique biomaterial and is used as a sealant or glue, a matrix for cells, a scaffold for tissue engineering, and a carrier and/or a vector for targeted drug delivery. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Wu, Xiuwen; Ren, Jianan; Wang, Gefei; Wang, Jianzhong; Wang, Feng; Fan, Yueping; Li, Yuanxin; Han, Gang; Zhou, Yanbing; Song, Xiaofei; Quan, Bin; Yao, Min; Li, Jieshou
2015-10-07
The management of an enterocutaneous fistula poses a significant challenge to surgeons and is often associated with a costly hospital stay and long-term discomfort. The use of fibrin glue in the fistula tract has been shown to promote closure of low output enterocutaneous fistulas. Our previous nonrandomized study demonstrated that autologous platelet-rich fibrin glue treatment significantly decreased time to fistula closure and promoted closure rates. However, there are several limitations in the study, which may lead to bias in our conclusion. Thus, a multicenter, randomized, controlled clinical trial is required. The study is designed as a randomized, open-label, three-arm, multicenter study in nine Chinese academic hospitals for evaluating the efficacy and safety of fibrin glue for sealing low-output fistulas. An established number of 171 fistula patients will undergo prospective random assignment to autologous fibrin glue, commercial porcine fibrin sealants or drainage cessation (1:1:1). The primary endpoint is fistula closure time (defined as the interval between the day of enrollment and day of fistula closure) during the 14-day treatment period. To our knowledge, this is the first study to evaluate the safety and efficacy of both autologous and commercial fibrin glue sealing for patients with low-output volume fistulas. NCT01828892 . Registration date: April 2013.
Wittmann, Katharina; Storck, Katharina; Muhr, Christian; Mayer, Helena; Regn, Sybille; Staudenmaier, Rainer; Wiese, Hinrich; Maier, Gerhard; Bauer-Kreisel, Petra; Blunk, Torsten
2016-10-01
Adipose tissue engineering aims at the restoration of soft tissue defects and the correction of contour deformities. It is therefore crucial to provide functional adipose tissue implants with appropriate volume stability. Here, we investigate two different fibrin formulations, alone or in combination with biodegradable polyurethane (PU) scaffolds as additional support structures, with regard to their suitability to generate volume-stable adipose tissue constructs. Human adipose-derived stem cells (ASCs) were incorporated in a commercially available fibrin sealant as well as a stable fibrin hydrogel previously developed by our group. The composite constructs made from the commercially available fibrin and porous poly(ε-caprolactone)-based polyurethane scaffolds exhibited increased volume stability as compared to fibrin gels alone; however, only constructs using the stable fibrin gels completely maintained their size and weight for 21 days. Adipogenesis of ASCs was not impaired by the additional PU scaffold. After induction with a common hormonal cocktail, for constructs with either fibrin formulation, strong adipogenic differentiation of ASCs was observed after 21 days in vitro. Furthermore, upregulation of adipogenic marker genes was demonstrated at mRNA (PPARγ, C/EBPα, GLUT4 and aP2; qRT-PCR) and protein (leptin; ELISA) levels. Stable fibrin/PU constructs were further evaluated in a pilot in vivo study, resulting in areas of well-vascularized adipose tissue within the implants after only 5 weeks. Copyright © 2013 John Wiley & Sons, Ltd. Copyright © 2013 John Wiley & Sons, Ltd.
[Use of adipose-derived stem cells in an experimental rotator cuff fracture animal model].
Barco, R; Encinas, C; Valencia, M; Carrascal, M T; García-Arranz, M; Antuña, S
2015-01-01
Rotator cuff repairs have shown a high level of re-ruptures. We hypothesized that the use of adipose-derived stem cells (ASC) could improve the biomechanical and histological properties of the repair. Controlled experimental study conducted on 44 BDIX rats with section and repair of the supraspinatus tendon and randomization to one of three groups: group A, no intervention (control); group B, local applications of a fibrin sealant; and group C, application of the fibrin sealant with 2 x 10(6) ASC. At 4 and 8 weeks a biomechanical and histological analysis was performed. There were no differences in load-to-failure at 4 and 8 weeks between groups. The load-to-failure did increase between week 4 and week 8. Histologically the tendon-to bone union showed a disorganized fibrovascular tissue. Group C showed a different inflammatory pattern, with less presence of neutrophils and more presence of plasma cells. The use of ASC does not improve the biomechanical or histological properties of the repair site. More studies are needed to improve techniques that enhance the healing site of the repair. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.
Salikhov, Ramil Z.; Masgutov, Ruslan F.; Chekunov, Mikhail A.; Tazetdinova, Leysan G.; Masgutova, Galina; Teplov, Oleg V.; Galimov, Damir; Plakseichuk, Yuri; Yagudin, Ramil; Pankov, Igor O.; Rizvanov, Albert
2018-01-01
In this study we applied autologous fat tissue stromal vascular fraction (SVF) cells in combination with microfracturing technique in a 36-year-old man with an osteochondral lesion of the medial femoral condyle 8 months after the injury. Cell material was generated by fat tissue liposuction from the anterior abdominal wall with subsequent extraction of the SVF and injected through a mini-arthrotomy portal with subsequent fibrin sealant fixation. The follow-up period was 2 years. Clinical score improved from 23 to 96 according to IKDC and from 10 to 90 according to EQ-VAS at 24 months follow-up. Magnetic resonance imaging (MRI) before the surgery revealed an osteochondral lesion with development of significant trabecular edema that remained unchanged for 6 months despite conservative treatment. MRI 1 and 2 years after the surgery showed the recovery of the damaged cartilage thickness with somewhat uneven structure and a decrease in the trabecular edema of the femoral condyle. The use of SVF cells with fibrin sealant fixation might be a promising approach in the treatment of osteochondral joint lesions. Further studies are required. PMID:29900170
Maniwa, Tomohiro; Kaneda, Hiroyuki; Saito, Yukihito
2009-06-01
Pulmonary fistulas caused by tumours are very fragile and difficult to suture directly. It is impossible to close pulmonary fistulas with tissue sealants when massive air leakage occurs in the low pressure of the respiratory tract. A 73-year-old man with a pneumothorax caused by lung cancer had suffered a persistent massive air leakage for more than one month. We used a fibrin glue-soaked polyglycolic acid (PGA) sheet for sealing the complicated fistula. In addition, the visceral pleura of the fistula was wrapped with the pedicle of an intercostal muscle (ICM) flap to prevent massive air leakage. The pneumothorax did not reappear after surgery. Thus, a fibrin glue-soaked PGA sheet covered with an ICM flap was effective for sealing an intractable air-leaking fistula caused by lung cancer.
Surgical Reconstruction of Ocular Surface Tumors Using Fibrin Sealant Tissue Adhesive.
Queiroz de Paiva, Aline Roseane; Abreu de Azevedo Fraga, Larissa; Torres, Virgínia Laura Lucas
2016-10-01
To evaluate the surgical outcomes of ocular surface reconstruction in corneal-conjunctival tumors using fibrin tissue adhesive. A prospective noncomparative study was performed between May 2013 and February 2015. Patients were submitted to routine surgical procedure for corneal-conjunctival tumor excision followed by amniotic membrane graft transplantation using fibrin tissue adhesive (Evicel®, Omrix Biopharmaceuticals Ltd., Israel). Results were assessed on the 1st, 7th, 15th and 30th postoperative days to analyze subjective complaints, adhesiveness and positioning of the graft, potential complications and recurrences. Twenty-five eyes were analyzed (male, 14). The diagnosis after the treatment was categorized as squamous cell neoplasia, dysplasia, actinic keratosis, squamous papilloma and compound melanocytic nevus. Few significant symptoms were reported, such as mild hyperemia and ocular dyscomfort. One case developed a conjunctival granuloma which regressed after topical treatment. All grafts were successful with no displacements or retraction postoperatively. There was no clinical recurrence of the tumor in a mean time of follow-up of 11 months. Fibrin tissue adhesive is safe and effective in the surgery of ocular surface tumor. In this series, sutureless amniotic membrane transplantation using fibrin glue has the potential to shorten the surgical time, mitigate inflammation postoperatively and improve patient discomfort.
Grambow, E; Heller, T; Wieneke, P; Weiß, C; Klar, E; Weinrich, M
2018-01-01
Duplex ultrasound is the first choice in diagnostics and surveillance of stenoses of the internal carotid arteries before and even after surgery. Therefore, the quality of duplex ultrasound is crucial to investigate these vascular pathologies. Aim of this study was the evaluation whether different surgical techniques affect the postoperative quality of duplex ultrasound. In a time period from January to May 2015 duplex ultrasound of the cervical vessels was performed in 75 patients after unilateral endarterectomy of the internal carotid artery at our department between 2006 and 2012. Thereby, the non-operated contralateral side served as a control. Study groups were defined by the surgical techniques of eversion- or thrombendarterectomy with patch plasty using different patch materials and/or a haemostatic sealant. Duplex ultrasound analysis included acoustic impedance, extinction of ultrasound, thickness of skin and individual anatomic aspects of the patients. Carotid endarterectomy itself reduced intravascular grey levels, skin thickness and increased extinction of duplex ultrasound when compared to the non-operated side of the neck. In contrast, neither the kind of chosen operative technique nor the use of different patch materials or the application of a haemostatic sealant showed an effect in this regards. Whereas carotid endarterectomy per se worsens the quality of postoperative duplex ultrasound, the different analysed surgical techniques as well as used patches and the application of a haemostatic sealant can be assumed to be equal regarding the quality of postoperative ultrasound.
Arkudas, Andreas; Pryymachuk, Galyna; Hoereth, Tobias; Beier, Justus P; Polykandriotis, Elias; Bleiziffer, Oliver; Gulle, Heinz; Horch, Raymund E; Kneser, Ulrich
2012-07-01
In this study, different fibrin sealants with varying concentrations of the fibrin components were evaluated in terms of matrix degradation and vascularization in the arteriovenous loop (AVL) model of the rat. An AVL was placed in a Teflon isolation chamber filled with 500 μl fibrin gel. The matrix was composed of commercially available fibrin gels, namely Beriplast (Behring GmbH, Marburg, Germany) (group A), Evicel (Omrix Biopharmaceuticals S.A., Somerville, New Jersey, USA) (group B), Tisseel VH S/D (Baxter, Vienna, Austria) with a thrombin concentration of 4 IU/ml and a fibrinogen concentration of 80 mg/ml [Tisseel S F80 (Baxter), group C] and with an fibrinogen concentration of 20 mg/ml [Tisseel S F20 (Baxter), group D]. After 2 and 4 weeks, five constructs per group and time point were investigated using micro-computed tomography, and histological and morphometrical analysis techniques. The aprotinin, factor XIII and thrombin concentration did not affect the degree of clot degradation. An inverse relationship was found between fibrin matrix degradation and sprouting of blood vessels. By reducing the fibrinogen concentration in group D, a significantly decreased construct weight and an increased generation of vascularized connective tissue were detected. There was an inverse relationship between matrix degradation and vascularization detectable. Fibrinogen as the major matrix component showed a significant impact on the matrix properties. Alteration of fibrin gel properties might optimize formation of blood vessels.
Azoury, S C; Rodriguez-Unda, N; Soares, K C; Hicks, C W; Baltodano, P A; Poruk, K E; Hu, Q L; Cooney, C M; Cornell, P; Burce, K; Eckhauser, F E
2015-12-01
The authors evaluated the ability of a fibrin sealant (TISSEEL™: Baxter Healthcare Corp, Deerfield, IL, USA) to reduce the incidence of post-operative seroma following abdominal wall hernia repair. We performed a 4-year retrospective review of patients undergoing abdominal wall hernia repair, with and without TISSEEL, by a single surgeon (FEE) at The Johns Hopkins Hospital. Demographics, surgical risk factors, operative data and 30-day outcomes, including wound complications and related interventions, were compared. The quantity and cost of Tisseel per case was reviewed. A total of 250 patients were evaluated: 127 in the TISSEEL group and 123 in the non-TISSEEL control group. The average age for both groups was 56.6 years (P = 0.97). The majority of patients were female (TISSEEL 52.8%, non-TISSEEL 56.1%, P = 0.59) and ASA Class III (TISSEEL 56.7%, non-TISSEEL 58.5%, P = 0.40). There was no difference in the average defect size for both groups (TISSEEL 217 ± 187.6 cm(2), non-TISSEEL 161.3 ± 141.5 cm(2), P = 0.36). Surgical site occurrences occurred in 18.1% of the TISSEEL and 13% of the non-TISSEEL group (P = 0.27). There was a trend towards an increased incidence of seroma in the TISSEEL group (TISSEEL 11%, non-TISSEEL 4.9%, P = 0.07). A total of $124,472.50 was spent on TISSEEL, at an average cost of $995.78 per case. In the largest study to date, TISSEEL™ application offered no advantage for the reduction of post-operative seroma formation following complex abdominal hernia repair. Moreover, the use of this sealant was associated with significant costs.
Platelet-Rich Plasma and Platelet Gel: A Review
Everts, Peter A.M.; Knape, Johannes T.A.; Weibrich, Gernot; Schönberger, Jacques P.A.M.; Hoffmann, Johannes; Overdevest, Eddy P.; Box, Henk A.M.; van Zundert, André
2006-01-01
Abstract: Strategies to reduce blood loss and transfusion of allogeneic blood products during surgical procedures are important in modern times. The most important and well-known autologous techniques are preoperative autologous predonation, hemodilution, perioperative red cell salvage, postoperative wound blood autotransfusion, and pharmacologic modulation of the hemostatic process. At present, new developments in the preparation of preoperative autologous blood component therapy by whole blood platelet-rich plasma (PRP) and platelet-poor plasma (PPP) sequestration have evolved. This technique has been proven to reduce the number of allogeneic blood transfusions during open heart surgery and orthopedic operations. Moreover, platelet gel and fibrin sealant derived from PRP and PPP mixed with thrombin, respectively, can be exogenously applied to tissues to promote wound healing, bone growth, and tissue sealing. However, to our disappointment, not many well-designed scientific studies are available, and many anecdotic stories exist, whereas questions remain to be answered. We therefore decided to study perioperative blood management in more detail with emphasis on the application and production of autologous platelet gel and the use of fibrin sealant. This review addresses a large variety of aspects relevant to platelets, platelet-rich plasma, and the application of platelet gel. In addition, an overview of recent animal and human studies is presented. PMID:16921694
Velasco, Jose Manuel Arévalo; Lozano, Virginia; Oyagüez, Itziar; Casado, Miguel Angel
2015-11-01
A comparative study was performed to evaluate the effectiveness and costs of a fibrin sealant (Tissucol Duo [known as Tisseel in the United States], Baxter International, Deerfield, Illinois) to improve postoperative outcomes in patients with spinal cord injury undergoing surgical treatment for pressure ulcers (PrUs). Between January and June 2011, 27 patients underwent surgical treatment for PrUs with the direct application of Tissucol Duo sprayed before closure. The costs and outcomes obtained in this cohort were compared with those obtained in a previous retrospective study where 71 patients underwent conventional surgery. Lower rates of hematoma-seroma were observed in the study group (3.7% vs 33.8%; P < .05). Drain removal occurred earlier (10 vs 15 days; P < .05), and the average drain volume was also lower (155 vs 360 mL; P < .05) for this group. The mean length of hospital stay was significantly lower in the study group and was the main contributing factor to the overall costs. The application of Tissucol Duo during surgical treatment of PrUs in patients with spinal cord injury has been shown to be effective in reducing postoperative complications and in shortening the duration of the hospital stay with a consequent savings in costs.
Mendez, Julio J.; Ghaedi, Mahboobe; Sivarapatna, Amogh; Dimitrievska, Sashka; Shao, Zhen; Osuji, Chinedum; Steinbacher, Derek M.; Leffell, David J.; Niklason, Laura E.
2014-01-01
Non-healing, chronic wounds are a growing public health problem and may stem from insufficient angiogenesis in affected sites. Here, we have developed a fibrin formulation that allows adipose-derived mesenchymal stromal cells (ADSCs) to form tubular structures in vitro. The tubular structures express markers of endothelium, including CD31 and VE-Cadherin, as well as the pericyte marker NG2. The ability for the MSCs to form tubular structures within the fibrin gels was directly dependent on the stoichiometric ratios of thrombin and fibrinogen and the resulting gel concentration, as well as on the presence of bFGF. Fibrin gel formulations that varied in stiffness were tested. ADSCs that are embedded in a stiff fibrin formulation express VE-cadherin and CD31 as shown by PCR, FACS and immunostaining. Confocal imaging analysis demonstrated that tubular structures formed, containing visible lumens, in the stiff fibrin gels in vitro. There was also a difference in the amounts of bFGF secreted by ADSCs grown in the stiffer gels as compared to softer gels. Additionally, hAT-MSCs gave rise to perfusable vessels that were VE-cadherin positive after subcutaneous injection into mice, whereas the softer fibrin formulation containing ADSCs did not. The application of ADSCs delivered in the stiff fibrin gels allowed for the wounds to heal more quickly, as assessed by wound size, amount of granulation tissue and collagen content. Interestingly, following 5 days of healing, the ADSCs remained within the fibrin gel and did not integrate into the granulation tissue of healing wounds in vivo. These data show that ADSCs are able to form tubular structures within fibrin gels, and may also contribute to faster wound healing, as compared with no treatment or to wounds treated with fibrin gels devoid of ADSCs. PMID:25433608
Injectible candidate sealants for fetal membrane repair: Bonding and toxicity in vitro
Bilic, Grozdana; Brubaker, Carrie; Messersmith, Phillip B.; Mallik, Ajit S.; Quinn, Thomas M.; Haller, Claudia; Done, Elisa; Gucciardo, Leonardo; Zeisberger, Steffen M.; Zimmermann, Roland; Deprest, Jan; Zisch, Andreas H.
2010-01-01
Objective This study was undertaken to test injectible surgical sealants that are biocompatible with fetal membranes, eventually for closure of iatrogenic membrane defects. Study Design Dermabond, Histoacryl, Tissucol fibrin glue, and three types of in situ forming poly(ethylene glycol)-based polymer hydrogels were tested for acute toxicity upon direct contact with fetal membranes for 24h. For determination of elution toxicity, extracts of sealants were incubated on amnion cell cultures for 72h. Bonding and toxicity was assessed through morphological and/or biochemical analysis. Results Extracts of all adhesives were non-toxic for cultured cells. However, only Tissucol and one type of poly(ethylene glycol)-based hydrogel, mussel-mimetic tissue adhesive, showed efficient, non-disruptive, non-toxic bonding to fetal membranes. Mussel-mimetic tissue adhesive applied over membrane defects created with a 3.5 mm trocar accomplished leak-proof closure that withstood membrane stretch in an in vitro model. Conclusion A synthetic hydrogel-type tissue adhesive emerged as potential sealing modality for iatrogenic membrane defects that merits further evaluation in vivo. PMID:20096254
Injectable tissue-engineered cartilage using commercially available fibrin glue.
Cakmak, Ozcan; Babakurban, Seda T; Akkuzu, Hatice G; Bilgi, Selcuk; Ovalı, Ercüment; Kongur, Merve; Altintas, Hande; Yilmaz, Bayram; Bilezikçi, Banu; Celik, Zerrin Y; Yakicier, Mustafa C; Sahin, Feride I
2013-12-01
To achieve injectable tissue-engineered cartilage using a commercially available fibrin sealant, and to determine the most suitable fibrin glue concentration, cartilage source, and cultured chondrocyte concentration. Animal research. A total of 28 immunocompetent New Zealand white rabbits were divided into four groups. The cultured chondrocytes from different anatomical sources carried in fibrin glue with and without aprotinin in different concentrations of fibrinogen and thrombin (Tisseell), were injected into forehead and interocular regions of the rabbits. The new tissue formation was harvested at 8 weeks and analyzed through gross and histological analysis. The new tissue formations were found in round, elliptical, and flat forms. The mean value of Tisseell and cell suspension was 0.8 cc in all of the rabbits' injection regions, but the mean volume of the samples in which immature cartilage matrix and mature cartilage was 0.1 cc. In the 20 of the 55 injection regions of rabbits (36, 36%), mature and/or immature cartilage formation were observed. We observed inflammatory reactions, abscess formation, and foreign body reactions around the new cartilage tissue of tissue-engineered cartilage. The comparison of results using different cartilage sources, chondrocyte concentrations, or different fibrin glue concentrations did not show any significant difference. We observed that changing the concentrations of ingredients of commercially available fibrin glue, the source of the cartilage, or the cultured chondrocyte concentration did not have significant effect on neocartilage formation. Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.
Platelet-rich fibrin matrix improves wound angiogenesis via inducing endothelial cell proliferation.
Roy, Sashwati; Driggs, Jason; Elgharably, Haytham; Biswas, Sabyasachi; Findley, Muna; Khanna, Savita; Gnyawali, Urmila; Bergdall, Valerie K; Sen, Chandan K
2011-11-01
The economic, social, and public health burden of chronic ulcers and other compromised wounds is enormous and rapidly increasing with the aging population. The growth factors derived from platelets play an important role in tissue remodeling including neovascularization. Platelet-rich plasma (PRP) has been utilized and studied for the last four decades. Platelet gel and fibrin sealant, derived from PRP mixed with thrombin and calcium chloride, have been exogenously applied to tissues to promote wound healing, bone growth, hemostasis, and tissue sealing. In this study, we first characterized recovery and viability of as well as growth factor release from platelets in a novel preparation of platelet gel and fibrin matrix, namely platelet-rich fibrin matrix (PRFM). Next, the effect of PRFM application in a delayed model of ischemic wound angiogenesis was investigated. The study, for the first time, shows the kinetics of the viability of platelet-embedded fibrin matrix. A slow and steady release of growth factors from PRFM was observed. The vascular endothelial growth factor released from PRFM was primarily responsible for endothelial mitogenic response via extracellular signal-regulated protein kinase activation pathway. Finally, this preparation of PRFM effectively induced endothelial cell proliferation and improved wound angiogenesis in chronic wounds, providing evidence of probable mechanisms of action of PRFM in healing of chronic ulcers. 2011 by the Wound Healing Society.
Nerve regeneration using tubular scaffolds from biodegradable polyurethane.
Hausner, T; Schmidhammer, R; Zandieh, S; Hopf, R; Schultz, A; Gogolewski, S; Hertz, H; Redl, H
2007-01-01
In severe nerve lesion, nerve defects and in brachial plexus reconstruction, autologous nerve grafting is the golden standard. Although, nerve grafting technique is the best available approach a major disadvantages exists: there is a limited source of autologous nerve grafts. This study presents data on the use of tubular scaffolds with uniaxial pore orientation from experimental biodegradable polyurethanes coated with fibrin sealant to regenerate a 8 mm resected segment of rat sciatic nerve. Tubular scaffolds: prepared by extrusion of the polymer solution in DMF into water coagulation bath. The polymer used for the preparation of tubular scaffolds was a biodegradable polyurethane based on hexamethylene diisocyanate, poly(epsilon-caprolactone) and dianhydro-D-sorbitol. EXPERIMENTAL MODEL: Eighteen Sprague Dawley rats underwent mid-thigh sciatic nerve transection and were randomly assigned to two experimental groups with immediate repair: (1) tubular scaffold, (2) 180 degrees rotated sciatic nerve segment (control). Serial functional measurements (toe spread test, placing tests) were performed weekly from 3rd to 12th week after nerve repair. On week 12, electrophysiological assessment was performed. Sciatic nerve and scaffold/nerve grafts were harvested for histomorphometric analysis. Collagenic connective tissue, Schwann cells and axons were evaluated in the proximal nerve stump, the scaffold/nerve graft and the distal nerve stump. The implants have uniaxially-oriented pore structure with a pore size in the range of 2 micorm (the pore wall) and 75 x 700 microm (elongated pores in the implant lumen). The skin of the tubular implants was nonporous. Animals which underwent repair with tubular scaffolds of biodegradable polyurethanes coated with diluted fibrin sealant had no significant functional differences compared with the nerve graft group. Control group resulted in a trend-wise better electrophysiological recovery but did not show statistically significant differences. There was a higher level of collagenic connective tissue within the scaffold and within the distal nerve stump. Schwann cells migrated into the polyurethane scaffold. There was no statistical difference to the nerve graft group although Schwann cell counts were lower especially within the middle of the polyurethane scaffold. Axon counts showed a trend-wise decrease within the scaffold. These results suggest that biodegradable polyurethane tubular scaffolds coated with diluted fibrin sealant support peripheral nerve regeneration in a standard gap model in the rat up to 3 months. Three months after surgery no sign of degradation could be seen.
Stability of Beriplast P fibrin sealant: storage and reconstitution.
Eberhard, Ulrich; Broder, Martin; Witzke, Günther
2006-04-26
This study was performed to investigate the stability of Beriplast P fibrin sealant (FS) across a range of storage conditions, both pre- and post-reconstitution. Storage stability of the FS was evaluated during long-term refrigeration (24 months) with or without interim storage at elevated temperatures (40 degrees C for 1 week and 25 degrees C for 1 and 3 months). Stability of individual FS components was assessed by measuring: fibrinogen content, Factor XIII activity (FXIII), thrombin activity and aprotinin potency. The package integrity of each component was also checked (sterility testing, moisture content and pH). Storage stability was also evaluated by testing the reconstituted product for adhesion (tearing force testing after mixing the solutions) and sterility. Reconstitution stability was evaluated following 3-months' storage, for up to 50 h post-reconstitution using the same tests as for the storage stability investigations. Pre-defined specifications were met for fibrinogen content, Factor XIII activity, and thrombin activity, demonstrating storage stability. Package integrity and the functionality and sterility of the reconstituted product were confirmed throughout. Reconstitution stability was demonstrated for up to 50 h following reconstitution, in terms of both tearing force and sterility tests. In conclusion, the storage stability of Beriplast P was demonstrated over a range of 24-month storage schedules including interim exposure to elevated temperature, and the reconstituted product was stable for up to 50 h.
Konca, Can; Yılmaz, Ali Abbas; Çelik, Süleyman Utku; Kayılıoğlu, Selami Ilgaz; Paşaoğlu, Özge Tuğçe; Ceylan, Halil Arda; Genç, Volkan
2018-05-29
Staple-line leak is the most frightening complication of laparoscopic sleeve gastrectomy and several predisposing factors such as using improper staple sizes regardless of gastric wall thickness, narrower bougie diameter and ischemia of the staple line are asserted. To evaluate the effects of different bougie diameters on tissue oxygen partial pressure at the esophagogastric junction after sleeve gastrectomy. A randomized and controlled animal experiment with 1:1:1:1 allocation ratio. Thirty-two male Wistar Albino rats were randomly divided into 4 groups of 8 each. While 12-Fr bougies were used in groups 1 and 3, 8-Fr bougies were used in groups 2 and 4. Fibrin sealant application was also carried out around the gastrectomy line after sleeve gastrectomy in groups 3 and 4. Burst pressure of gastrectomy line, tissue oxygen partial pressure and hydroxyproline levels at the esophagogastric junction were measured and compared among groups. Mortality was detected in 2 out of 32 rats (6.25%) and one of them was in group 2 and the cause of this mortality was gastric leak. Gastric leak was detected in 2 out of 32 rats (6.25%). There was no significant difference in terms of burst pressures, tissue oxygen partial pressure and tissue hydroxyproline levels among the 4 groups. The use of narrower bougie along with fibrin sealant has not had a negative effect on tissue perfusion and wound healing.
Nakamura, Hiroshi; Matsuyama, Yukihiro; Yoshihara, Hisatake; Sakai, Yoshihito; Katayama, Yoshito; Nakashima, Shojiro; Takamatsu, Jyunki; Ishiguro, Naoki
2005-07-01
A prospective randomized study evaluating the efficacy of autologous fibrin tissue adhesive for decreasing postoperative cerebrospinal fluid (CSF) leak in spinal cord surgery. To compare postoperative CSF leak in 3 groups (i.e., autologous fibrin tissue adhesive used, commercial fibrin glue used, and no fibrin tissue adhesive used) of patients undergoing spinal surgery who needed dural incision. Spinal cord operations, particularly when dural incision is inevitable, sometimes involve postoperative CSF leak. Because CSF leak is a serious complication, countermeasure is necessary to prevent it after dural suture. Commercial fibrin tissue adhesive was formerly used. Because the possibility of prion infection was widely noticed, commercial fibrin tissue adhesive containing animal components has been used less often. In 13 of 39 cases in which dural incision would be made, 400 mL whole blood was drawn, and autologous fibrin tissue adhesive was made of plasma. Cases were divided into 3 groups: (1) dural closure alone, (2) use of autologous fibrin tissue adhesive after dural closure, and (3) use of commercial fibrin tissue adhesive after dural closure. The primary outcome measure was determined as postoperative (3 days) volume of drainage fluid, and results were analyzed using the analysis of variance. The secondary outcome measure was general blood test, coagulation assay, and plasma fibrinogen, and these were analyzed also using the analysis of variance. There was a significant difference in the primary outcome between the autologous and control groups. No complications such as infection or continuous CSF leak were observed in any case. The mean volume of drainage fluid was 586.2 mL in the group with autologous fibrin tissue adhesive and 1026.1 mL in the group without fibrin tissue adhesive. The volume of drainage fluid was significantly lower in the former group than that in the latter group. There was no statistical difference between the volumes of the group with autologous adhesive and with commercial adhesive (639.2 mL). We used autologous fibrin tissue adhesive as a new sealant after dural closure instead of commercial fibrin tissue adhesive. No definitive CSF leak was observed, and the volume of drainage fluid was significantly lower in the group with autologous fibrin tissue adhesive than that in the group without fibrin tissue adhesive. The use of autologous fibrin tissue adhesive was superior to that of commercial fibrin tissue adhesive in cost.
[Pterygium surgery and fibrin glue: avoiding dehiscence].
Pérez-Silguero, D; Díaz-Ginory, A; Santana-Rodríguez, C; Pérez-Silguero, M A
2014-01-01
The purpose of the study is to evaluate those cases of pterygium surgery with fibrin sealant that produced dehiscence of the graft, and then apply and evaluate the efficacy of a different surgical technique in an attempt eliminate this complication in previously identified cases of high risk. The first phase is a retrospective study of 42 cases of pterygium surgery. In the second phase, the variation in the surgical technique was prospectively used in 14 cases of pterygium surgery. Cases of recurrent pterygium, broad pterygium, and complicated surgery were identified as the groups with a risk of suffering dehiscence of the graft. With the variant applied surgery no dehiscence occurred when using the variation in surgical technique, with no added complications. Copyright © 2012 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.
Lazarini, Mariana; Bordeaux-Rego, Pedro; Giardini-Rosa, Renata; Duarte, Adriana S S; Baratti, Mariana Ozello; Zorzi, Alessandro Rozim; de Miranda, João Batista; Lenz Cesar, Carlos; Luzo, Ângela; Olalla Saad, Sara Teresinha
2017-10-01
Objective Articular cartilage is an avascular tissue with limited ability of self-regeneration and the current clinical treatments have restricted capacity to restore damages induced by trauma or diseases. Therefore, new techniques are being tested for cartilage repair, using scaffolds and/or stem cells. Although type II collagen hydrogel, fibrin sealant, and adipose-derived stem cells (ASCs) represent suitable alternatives for cartilage formation, their combination has not yet been investigated in vivo for focal articular cartilage defects. We performed a simple experimental procedure using the combination of these 3 compounds on cartilage lesions of rabbit knees. Design The hydrogel was developed in house and was first tested in vitro for chondrogenic differentiation. Next, implants were performed in chondral defects with or without ASCs and the degree of regeneration was macroscopically and microscopically evaluated. Results Production of proteoglycans and the increased expression of collagen type II (COL2α1), aggrecan (ACAN), and sex-determining region Y-box 9 (SOX9) confirmed the chondrogenic character of ASCs in the hydrogel in vitro. Importantly, the addition of ASC induced a higher overall repair of the chondral lesions and a better cellular organization and collagen fiber alignment compared with the same treatment without ASCs. This regenerating tissue also presented the expression of cartilage glycosaminoglycan and type II collagen. Conclusions Our results indicate that the combination of the 3 compounds is effective for articular cartilage repair and may be of future clinical interest.
Benitez, Suzana U.; Barbizan, Roberta; Spejo, Aline B.; Ferreira, Rui S.; Barraviera, Benedito; Góes, Alfredo M.; de Oliveira, Alexandre L. R.
2014-01-01
Root lesions may affect both dorsal and ventral roots. However, due to the possibility of generating further inflammation and neuropathic pain, surgical procedures do not prioritize the repair of the afferent component. The loss of such sensorial input directly disturbs the spinal circuits thus affecting the functionality of the injuried limb. The present study evaluated the motor and sensory improvement following dorsal root reimplantation with fibrin sealant (FS) plus bone marrow mononuclear cells (MC) after dorsal rhizotomy. MC were used to enhance the repair process. We also analyzed changes in the glial response and synaptic circuits within the spinal cord. Female Lewis rats (6–8 weeks old) were divided in three groups: rhizotomy (RZ group), rhizotomy repaired with FS (RZ+FS group) and rhizotomy repaired with FS and MC (RZ+FS+MC group). The behavioral tests electronic von-Frey and Walking track test were carried out. For immunohistochemistry we used markers to detect different synapse profiles as well as glial reaction. The behavioral results showed a significant decrease in sensory and motor function after lesion. The reimplantation decreased glial reaction and improved synaptic plasticity of afferent inputs. Cell therapy further enhanced the rewiring process. In addition, both reimplanted groups presented twice as much motor control compared to the non-treated group. In conclusion, the reimplantation with FS and MC is efficient and may be considered an approach to improve sensory-motor recovery following dorsal rhizotomy. PMID:25249946
Silver microparticles plus fibrin tissue sealant prevents incisional hernias in rats.
Primus, Frank E; Young, David M; Grenert, James P; Harris, Hobart W
2018-07-01
Open abdominal surgery is frequently complicated by the subsequent development of an incisional hernia. Consequently, more than 400,000 incisional hernia repairs are performed each year, adding over $15 billion per year to U.S. health-care expenditures. While the vast majority of studies have focused on improved surgical techniques or prosthetic materials, we examined the use of metallic silver microparticles to prevent incisional hernia formation through enhanced wound healing. A rodent incisional hernia model was used. Eighty-two rats were randomly placed into two control groups (saline alone and silver microparticles alone), and three experimental groups (0 mg/cm, 2.5 mg/cm, and 25 mg/cm of silver microparticles applied with a fibrin sealant). Incisional hernia incidence and size, tensile strength, and tissue histology were assessed after 28 days. A significant reduction of both incisional hernia incidence and hernia size was observed between the control groups and 2.5 mg/cm group, and between the control and 25 mg/cm group by nearly 60% and 90%, respectively (P < 0.05). Histological samples showed a noticeable increase in new fibrosis in the treated animals as compared with the controls, whereas the tensile strength between the groups did not differ. The novel approach of using silver microparticles to enhance wound healing appears to be a safe and effective method to prevent incisional hernias from developing and could herald a new era of medicinal silver use. Copyright © 2018 Elsevier Inc. All rights reserved.
Sakai, Takashi; Matsutani, Noriyuki; Kanai, Eiichi; Yamauchi, Yoshikane; Uehara, Hirofumi; Iinuma, Hisae; Kawamura, Masafumi
2018-02-01
Polyglycolic acid and oxidized regenerated cellulose have been widely used as a sealant for repairing pulmonary air leakage during respiratory surgery. However, fundamental research of these materials has not been sufficiently conducted. Therefore, we conducted studies to assess the pressure resistance ability of these materials using a canine visceral pleural defect model at the early phase. The 6-mm circular defect and the 12-mm square defect were created on the visceral pleura of anesthetized beagles. These defects were then repaired using one of four methods: method A using polyglycolic acid and fibrin glue; method B using oxidized regenerated cellulose and fibrin glue; method C using oxidized regenerated cellulose; method D using fibrin glue. Airway pressure was measured as bursting pressure when air leakage from the repaired areas occurred at 5 min, 3 h, and 24 h after repair. For the 6-mm circle defect, method A showed higher bursting pressures than the other methods at 5 min and 3 h (p < 0.05); method B showed higher than methods C and D at 5 min and 3 h (p < 0.05). For the 12-mm square defect, method A showed higher bursting pressures than the other methods at all time points (p < 0.05). Moreover, method B showed higher than method C at 24 h (p < 0.05). Visceral pleural repairs using polyglycolic acid combined with fibrin glue showed the highest bursting pressure. Oxidized regenerated cellulose combined with fibrin glue showed sufficiently high bursting pressure in repair of small 6-mm circular defects.
Chetter, Ian; Stansby, Gerard; Sarralde, José Aurelio; Riambau, Vicente; Giménez-Gaibar, Antonio; MacKenzie, Kent; Acín, Francisco; Navarro-Puerto, Jordi
2017-11-01
Anastomotic or "stitch hole" bleeding is common during vascular surgery with synthetic material such as Dacron or polytetrafluoroethylene. Hemostatic adjuncts such as fibrin sealant (FS) may reduce blood loss and operating time in such circumstances. We evaluated the safety and the hemostatic effectiveness of a ready-to-use human plasma-derived FS in vascular surgery. Patients with mild/moderate suture line bleeding during elective, open, vascular surgery using synthetic grafts or patches were studied. In an initial Exploratory Study, all patients were treated with FS Grifols, and in a subsequent Primary Study were randomized in a 2:1 ratio to FS Grifols or manual compression (MC). The primary efficacy end point was time to hemostasis (TTH), assessed at defined intervals from the start of treatment application, during a 10-min observational period. Safety end points (in Exploratory + Primary Studies) included adverse events (AEs), vital signs, physical assessments, common clinical laboratory tests (coagulation, complete blood count, serum clinical chemistry parameters, microscopic urinalysis), viral markers, and immunogenicity. In the Primary Study, the proportion of patients who achieved hemostasis at the 3-min time point was higher in the FS Grifols group (46.4%, n = 51/110) than in the MC group (26.3%, n = 15/57) (P < 0.05). The benefit was maintained at successive time intervals: 69 FS Grifols patients (62.7%) and 18 MC patients (31.6%) at 4 min; 82 FS Grifols patients (74.5%) and 28 MC patients (49.1%) at 5 min. The differences between the groups persisted for TTH ≤ 7 min and TTH ≤ 10 min. Treatment failure was reported for 13 FS Grifols patients (11.8%) and 16 MC patients (28.1%). TTH was shorter after FS Grifols application than after MC application. Differences were statistically significant in favor of FS Grifols for each TTH category and for the overall comparison (P < 0.001) as well as for each TTH category (cumulative) and for treatment failure (P = 0.016). Overall, AE experience and types of AEs reported were those expected in this patient population and were similar between the 2 treatment groups. The most frequently reported AEs were procedural pain (59.9% and 69.2% of patients in the FS Grifols [n = 72 + 111] and MC [n = 57] groups, respectively) and nausea (23.5% and 19.2% of patients, respectively). FS Grifols was efficacious and safe as an adjunct to anastomotic hemostasis in patients undergoing arterial surgery using prosthetic material with mild to moderate bleeding. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Hemostatic agents and instruments in laparoscopic renal surgery.
Msezane, Lambda P; Katz, Mark H; Gofrit, Ofer N; Shalhav, Arieh L; Zorn, Kevin C
2008-03-01
Control of bleeding is one of the most technically challenging steps in laparoscopic renal surgery, especially partial nephrectomy. Although there is no consensus on how best to approach hemostasis, the options continue to expand. The original method of sutured renorrhaphy is, perhaps, the most effective; however, great skill is needed to avoid prolonged warm ischemia. Tissue sealants and adhesives serve as a barrier to leakage and as a hemostat. The four classes are fibrin sealants, collagen-based adhesives, hydrogel, and glutaraldehyde-based adhesive. Additionally, oxidized cellulose can be applied to the surface of kidney or used as a bolster. Fibrin sealants are self-activating and work best on a dry field. The gelatin matrix agent consists of human-derived thrombin with a calcium chloride solution and bovine-derived gelatin matrix. The fibrinogen required to form a clot comes from autologous blood. Another product is polyethylene glycol-based hydrogel, which acts as a mechanical sealant. The tissue glue consists of bovine serum albumin and glutaraldehyde, which cross-link to each other, as well as to other tissue proteins. Excessive use or spillage around the renal pelvis and ureter may compromise urinary flow. The methylcellulose products, consisting of oxidized cellulose sheets, usually are positioned within a sutured bolster and act in part by providing direct pressure. A number of energy-based technologies also have been utilized. Monopolar cautery consists of a high-frequency electrical current delivered from a single electrode. Care must be taken to avoid injurious current transfer to surrounding structures. With bipolar cautery, hemostasis occurs only between the electrodes. In the argonbeam coagulator, argon, an inert non-flammable gas that clears from the body rapidly, is coupled with an electrosurgical generator. The gas creates a more even distribution of the energy and better sealing of the tissues. There have been a few reports of serious complications, including gas embolism and tension pneumothorax. The holmium:YAG laser simultaneously dissects and coagulates tissue. However, its use may be limited by smoke and by blood splashing onto the camera lens, and the tissue vaporization and liquid could promote tumor-cell spillage. The potassium-titanyl-phosphate (KTP) and diode lasers have shown promise in animal studies. The saline-coupled radiofrequency tool uses a standard electrosurgical generator to deliver energy through the conductive fluid. The fluid keeps the surface temperature much lower, increases the contact area, and reduces char and eschar formation. One caveat for the use of instruments that coagulate and ablate tissue is that they can damage the collecting system. Furthermore, the char can make it difficult to assess margin status. In practice, a combination of instruments, sealants, or both generally is utilized to obtain hemostasis. These multimodality efforts may be especially useful in the patient with compromised renal function. On the other hand, the cost can rise quickly when multiple agents are employed. Combining suturing and hemostatic technology may be the best strategy.
Evolution of treatment of fistula in ano.
Blumetti, J; Abcarian, A; Quinteros, F; Chaudhry, V; Prasad, L; Abcarian, H
2012-05-01
Fistula-in-ano is a common medical problem affecting thousands of patients annually. In the past, the options for treatment of fistula-in-ano were limited to fistulotomy and/or seton placement. Current treatment options also include muscle-sparing techniques such as a dermal island flap, endorectal advancement flap, fibrin sealent injection, anal fistula plug, and most recently ligation of the intersphincteric fistula tract (procedure). This study seeks to evaluate types and time trends for treatment of fistula-in-ano. A retrospective review from 1975 to 2009 was performed. Data were collected and sorted into 5-year increments for type and time trends of treatment. Fistulotomy and partial fistulotomy were grouped as cutting procedures. Seton placement, fibrin sealant, dermal flap, endorectal flap, and fistula plug were grouped as noncutting procedures. Statistical analysis was performed for each time period to determine trends. With institutional review board approval, the records of 2,267 fistula operations available for analysis were included. Most of the patients were men (74 vs. 26%). Cutting procedures comprised 66.6% (n = 1510) of all procedures. Noncutting procedures were utilized in 33.4% (n = 757), including Seton placement alone 370 (16.3%), fibrin sealant 168 (7.4%), dermal or endorectal flap 147 (6.5%), and fistula plug 72 (3.2%). The distribution of operations grouped in 5-year intervals is as follows: 1975-1979, 78 cutting and one noncutting; 1980-1984, 170 cutting and 10 noncutting; 1985-1989, 54 cutting and five noncutting; 1990-1994, 37 cutting and six noncutting; 1995-1999, 367 cutting and 167 noncutting; 2000-2004, 514 cutting and 283 noncutting; 2005-2009, 290 cutting and 285 noncutting. The percentage of cutting and noncutting procedures significantly differed over time, with cutting procedures decreasing and noncutting procedures increasing proportionally (χ(2) linear-by-linear association, p < 0.05). Fistula-in-ano remains a common complex disease process. Its treatment has evolved to include a variety of noncutting techniques in addition to traditional fistulotomy. With the advent of more sphincter-sparing techniques, the number of patients undergoing fistulotomy should continue to decrease over time. Surgeons should become familiar with various surgical techniques so the treatment can be tailored to the patient.
Vidal-Pérez, Óscar; Flores-Siguenza, Luis; Valentini, Mauro; Astudillo-Pombo, Emiliano; Fernández-Cruz, Laureano; García-Valdecasas, Juan Carlos
2016-01-01
In recent years, several publications have shown that new adhesives and sealants, like Tissucol(®), applied in thyroid space reduce local complications after thyroidectomies. To demonstrate the effectiveness of fibrin glue Tissucol(®) in reducing the post-operative hospital stay of patients operated on for differentiated thyroid carcinoma in which total thyroidectomy with central and unilateral node neck dissection was performed (due to the debit drains decrease), with consequent cost savings. A prospective randomised study was conducted during the period between May 2009 and October 2013 on patients with differentiated thyroid carcinoma with cervical nodal metastases, and subjected to elective surgery. Two groups were formed: one in which Tissucol(®) was used (case group) and another where it was not used (control group). Patients were operated on by surgeons specifically dedicated to endocrine surgical pathology, using the same surgical technique in all cases. A total of 60 total thyroidectomies with lymph node dissection were performed, with 30 patients in the case group, and 30 patients in control group. No statistically significant differences were observed in most of the studied variables. However, the case group had a shorter hospital stay than the control group with a statistically significant difference (p<0.05). Implementation of Tissucol(®) has statistically and significantly reduced the hospital stay of patients undergoing total thyroidectomy with neck dissection, which represents a significant reduction in hospital costs. This decrease in hospital stay has no influence on the occurrence of major complications related to the intervention. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.
Abaeva, Anastasia A.; Canault, Matthias; Kotova, Yana N.; Obydennyy, Sergey I.; Yakimenko, Alena O.; Podoplelova, Nadezhda A.; Kolyadko, Vladimir N.; Chambost, Herve; Mazurov, Aleksei V.; Ataullakhanov, Fazoil I.; Nurden, Alan T.; Alessi, Marie-Christine; Panteleev, Mikhail A.
2013-01-01
Strongly activated “coated” platelets are characterized by increased phosphatidylserine (PS) surface expression, α-granule protein retention, and lack of active integrin αIIbβ3. To study how they are incorporated into thrombi despite a lack of free activated integrin, we investigated the structure, function, and formation of the α-granule protein “coat.” Confocal microscopy revealed that fibrin(ogen) and thrombospondin colocalized as “cap,” a single patch on the PS-positive platelet surface. In aggregates, the cap was located at the point of attachment of the PS-positive platelets. Without fibrin(ogen) retention, their ability to be incorporated in aggregates was drastically reduced. The surface fibrin(ogen) was strongly decreased in the presence of a fibrin polymerization inhibitor GPRP and also in platelets from a patient with dysfibrinogenemia and a fibrinogen polymerization defect. In contrast, a fibrinogen-clotting protease ancistron increased the amount of fibrin(ogen) and thrombospondin on the surface of the PS-positive platelets stimulated with collagen-related peptide. Transglutaminases are also involved in fibrin(ogen) retention. However, platelets from patients with factor XIII deficiency had normal retention, and a pan-transglutaminase inhibitor T101 had only a modest inhibitory effect. Fibrin(ogen) retention was normal in Bernard-Soulier syndrome and kindlin-3 deficiency, but not in Glanzmann thrombasthenia lacking the platelet pool of fibrinogen and αIIbβ3. These data show that the fibrin(ogen)-covered cap, predominantly formed as a result of fibrin polymerization, is a critical mechanism that allows coated (or rather “capped”) platelets to become incorporated into thrombi despite their lack of active integrins. PMID:23995838
Cappabianca, Paolo; Esposito, Felice; Magro, Francesco; Cavallo, Luigi Maria; Solari, Domenico; Stella, Lucio; de Divitiis, Oreste
2010-05-01
The objective of this study is to report our experience and illustrate our technique in the use of fibrin glue in the treatment of post-operatory cerebrospinal fluid (CSF) leaks and collections following different neurosurgical procedures. In a 3-year period, 40 subjects underwent endoscopic endonasal approach for different sellar and skull base lesions (three tuberculum sellae meningiomas, six craniopharyngiomas, three Rathke's cleft cysts and 28 pituitary macroadenomas), in which an intraoperative CSF leakage was evident. In such subjects, the fibrin glue was used as a first step of the final phase of the procedure-i.e. the reconstruction of the skull base defect-followed by the other materials employed. Furthermore, ten other patients, who had undergone transsphenoidal (four cases), spinal (two cases), posterior fossa (three cases) and transcortical intraventricular tumour removal (one case) neurosurgical procedures and developed CSF leaks or collections, were conservatively treated by single or repeated in situ injections of "modified" fibrin glue under local anaesthesia according to different described techniques. In total, 50 patients constitute the clinical material of the present study. In the cases where the fibrin glue was used during the reconstruction phase of the procedure (40 cases), the glue was injected inside the tumour cavity to fill the dead space left by the removal of the lesion. In case of post-operative CSF leak or CSF fluid collection (ten cases), after discarding 50-80% of the thrombin solution to obtain prevalence of the product's adhesive properties, fibrin glue was injected directly in the path of the CSF leak or into the collection cavity after aspiration of the collection's content. This was performed with the provided application system or through lumbar or Tuohy needles. Applications were repeated every 48 h until the disappearance of the leak. In all the treated cases, the disappearance of CSF leaks or collections was obtained with a number of applications ranging from one to five. Successful results are stable with a follow-up ranging from 6 months to 3 years. In our experience, the injection of fibrin glue has proved to be effective in filling or sealing post-operative "dead spaces" and treating minor or initial CSF leaks resulting from procedures of transsphenoidal, cranial and spinal surgery, adding another possibility in the management of many of these dreadful complications.
Use of duraseal in repair of cerebrospinal fluid leaks.
Chin, Christopher J; Kus, Lukas; Rotenberg, Brian W
2010-10-01
The purpose of our article is to review the use of the DuraSeal Sealant System (Confluent Surgical Inc., Waltham, MA) in the repair of complex cerebrospinal fluid (CSF) leaks in endoscopic skull-base surgery. Retrospective chart review. London Health Sciences Centre. A database of endoscopic skull-base cases between 2007 and 2009 that involved CSF leakage repaired with DuraSeal was created. Demographic data and operative reports were collected and analyzed qualitatively. Recurrence of CSF leak after repair. Five cases were identified that met study criteria. In four of the five cases, the repair was successful. There were no complications related to DuraSeal use. Comparison to a subset of patients using Tisseel Fibrin Sealant (Baxter, Toronto, ON) for repair did not show a significant difference in failure rate (χ2 = 0.029, p = .858). There are a variety of techniques described to repair CSF rhinorrhea, with various studies demonstrating the advantages of using tissue glues in CSF leak repairs. We used DuraSeal in five patients to enhance graft strength and form a watertight seal. The system was effective in the majority of patients. Our study is the first to report on endoscopic endonasal repair of CSF leaks using DuraSeal.
Gür, Özer Erdem; Ensari, Nuray; Öztürk, Mehmet Türker; Boztepe, Osman Fatih; Gün, Taylan; Selçuk, Ömer Tarık; Renda, Levent
2016-10-01
(1) To evaluate the effects of a platelet-rich fibrin (PRF) membrane in the repair of traumatic tympanic membrane (TM) perforations; and (2) to compare the use of a PRF membrane with the paper patch technique with regard to recovery rates, healing time, and correction of the mean air-bone gap. A randomized, prospective analysis was performed for 60 patients who were treated for traumatic TM perforations using one of the two methods. Closure rate, speed of healing, and hearing gain were compared between the PRF (Group 1) and paper patch (Group 2) groups. Closure was obtained in 28 (93%) perforations in Group 1 and 25 (83%) perforations in Group 2 (p > 0.05). On day 10, full closure of the TM was observed in 24 (80%) patients in Group 1 and 16 (53%) patients in Group 2 (p < 0.05). The improvement in the mean air-bone gap was 14.1 dB in Group 1 and 12.4 dB in Group 2 on post-operative day 45 (p < 0.05). In comparison with the paper patch method, PRF, a new method, provided more rapid healing with more successful audiological results, and with no requirement for a second procedure.
Gao, Fuqiang; Ma, Jinhui; Sun, Wei; Guo, Wanshou; Li, Zirong; Wang, Weiguo
2016-08-01
Efficacy and safety of topical application of a fibrin sealant (FS) compared with intravenous administration of tranexamic acid (TXA) for reducing blood loss after total knee arthroplasty (TKA) is controversial. We undertook a meta-analysis to compare the effects of topical application of FS or intravenous administration of TXA on blood loss after TKA. PubMed, Medline, Embase, Web of Science and the Cochrane Library were searched to identify studies comparing FS with TXA for TKA patients. The mean difference (MD) of blood loss, hemoglobin value, and odds ratios (ORs) of transfusion requirements and adverse events in FS and TXA groups were pooled throughout the study. Relevant data were analyzed using RevMan v5.3. Five studies involving 359 patients were included (181 FS vs. 178 TXA). TXA use had a significantly lower prevalence of blood transfusion (OR = 3.14; 95% confidence interval (CI), 1.67 to 5.90, P = 0.0004) and higher hemoglobin level (MD = -1.23; 95% CI, -2.19 to -0.27, P = 0.01) than FS in the early postoperative period. No significant difference was seen in total blood loss between the two groups (MD = 198.06; 95% CI, -267.45 to 663.57; P = 0.40). There were no significant differences in adverse events, superficial infections, or deep-vein thrombosis among study groups. Our meta-analysis suggests that intravenous administration of TXA for patients undergoing TKA may reduce blood-transfusion requirements and maintain higher hemoglobin levels compared with topical application of FS in the early postoperative period. There were no significant differences in total calculated blood loss and prevalence of complications between the two groups. However, owing to the variation of included studies, no firm conclusions can be drawn. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.
Use of an autologous leucocyte and platelet-rich fibrin patch on hard-to-heal DFUs: a pilot study.
Löndahl, M; Tarnow, L; Karlsmark, T; Lundquist, R; Nielsen, A M; Michelsen, M; Nilsson, A; Zakrzewski, M; Jörgensen, B
2015-04-01
Leucopatch is a leukocyte and platelet-rich fibrin patch that provides concentrated blood cells and signal substances to the surface of an ulcer. It is produced by centrifugation of the patient's own venous blood. The aim of this pilot multicentre cohort study was to evaluate effects of the leucocyte patch in patients with hard-to-heal diabetic foot ulcers (DFUs). Non-ischaemic Wagner grade 1 or 2 DFUs with a duration of more than 6 weeks and a maximal area of 10cm² were included. Patients with >40% ulcer area change during a two-week run-in period were excluded. The treatment was applied once a week for up to 19 treatments or until the foot ulcer was completely epithelialised. The primary endpoint was healing within 20 weeks. Of the 60 patients who gave consent 16 were excluded during run-in period, 44 patients initiated study treatment and 39 were included in the per-protocol analysis. Complete epithelisation was achieved in 34% (per-protocol analysis 36%) at 12 weeks and 52% (59%) at 20 weeks. In patients with ulcer duration less than 6 months, 73% of ulcers healed within 20 weeks. Patients with healed ulcers had larger ulcer area reduction during the first two treatment weeks compared to non-healers. Adverse events were mild and rare. The leucocyte patch is well-tolerated, easy to use and has potential in the armamentarium of the DFU treatment, provided this outcome is confirmed in an appropriately powered randomised clinical trial.
Berney, Christophe R; Descallar, Joseph
2016-10-01
Chronic pain is a common complication arising after conventional open herniorrhaphy and to a lesser extent postlaparoscopic inguinal hernia repairs as groin incision is avoided. Although published studies support elimination of mesh fixation during endoscopic procedures, the vast majority of surgeons will still recommend it by fear of encountering increased recurrence rates, if omitted. Regrettably, penetrating staple or tack fixation devices are the preferred methods to secure the mesh and cannot be applied at the level of the triangles of 'doom' and 'pain' where hernia tends to reoccur the most. This ongoing prospective cohort study aimed to confirm the safety and advantages of fibrin glue, as a substitute to staple mesh fixation during totally extraperitoneal (TEP) inguinal hernia repair. Over a 10-year period, 703 patients underwent 1000 elective TEP inguinal hernia repairs. Mesh fixation was achieved using exclusively fibrin sealant. Patients were reviewed at 2, 6 weeks and thereafter on an ad hoc basis if judged necessary until complete resolution of their symptoms. Quality of life (QoL) was assessed in a subgroup of 320 patients using the Carolina Comfort Scale (CCS). No conversion to open surgery was observed. There were three cases of major morbidities and no mortality. Three months after surgery, only seven patients (1 %) experienced chronic groin or testicular discomfort and none of them required prescription painkillers. When using the CCS, at 2 weeks 93.1 % of the patients were either satisfied or very satisfied with their outcome. This satisfaction index increased up to 99.2 % at 6 weeks post surgery. Finally, only eight hernia recurrences (1.1 %) were reported, of which five occurred during the first month of the study. Fibrin glue mesh fixation of inguinal hernia during TEP repair is extremely safe and reliable, with a very high satisfaction index for the patients and limited risk of developing chronic pain.
Mussel mimetic tissue adhesive for fetal membrane repair: initial in vivo investigation in rabbits.
Kivelio, A; Dekoninck, P; Perrini, M; Brubaker, C E; Messersmith, P B; Mazza, E; Deprest, J; Zimmermann, R; Ehrbar, M; Ochsenbein-Koelble, N
2013-12-01
Iatrogenic preterm prelabour rupture of fetal membranes (iPPROM) remains the main complication after invasive interventions into the intrauterine cavity. The aim of this study was to evaluate the sealing capability and tissue interaction of mussel-mimetic tissue adhesive (mussel glue) in comparison to fibrin glue on punctured fetal membranes in vivo. A mid-gestational rabbit model was used for testing the materials. The fetal sacs of pregnant rabbits at day 23 were randomly assigned into experimental groups: unoperated (negative control), unclosed puncture (positive control), commercially available fibrin glue (FG) with decellularized amnion scaffold (DAM), mussel glue (MG) with DAM, or mussel glue alone. Evaluation was done at term (30 days' gestation) assessing fetal survival, fetal membrane integrity and histology of the membranes. Fetal survival was not significantly lower in any of the treatment groups compared to the negative control. All plugging materials could be found at the end of the pregnancy and no adverse effects on the fetus or the pregnant does could be observed. Sac integrity was higher in all treatment groups compared to the positive control group but significant only in the FG+DAM group. Cellular infiltration could be seen in fibrin glue and DAM in contrast to mussel glue which was only tightly adhering to the surrounding tissue. These cells were mostly of mesenchymal phenotype staining positive for vimentin. CD68 positive macrophages were found clustered around all the plugging materials, but their numbers were only significantly increased for the mussel glue alone group compared to negative controls. Mussel glues performance in sealing fetal membranes in the rabbit model was comparable to that of fibrin glue. Taking into account its other favorable properties, it is a noteworthy candidate for a clinically applicable fetal membrane sealant. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Game, Frances; Jeffcoate, William; Tarnow, Lise; Day, Florence; Fitzsimmons, Deborah; Jacobsen, Judith
2017-10-10
Diabetic foot ulcers are a common and severe complication of diabetes mellitus. Standard treatment includes debridement, offloading, management of infection and revascularisation where appropriate, although healing times may be long. The LeucoPatch® device is used to generate an autologous platelet-rich fibrin and leucocyte wound dressing produced from the patient's own venous blood by centrifugation, but without the addition of any reagents. The final product comprises a thin, circular patch composed predominantly of fibrin together with living platelets and leucocytes. Promising results have been obtained in non-controlled studies this system, but this now needs to be tested in a randomised controlled trial (RCT). If confirmed, the LeucoPatch® may become an important new tool in the armamentarium in the management of diabetic foot ulcers which are hard-to-heal. People with diabetes and hard-to-heal ulcers of the foot will receive either pre-specified good standard care or good standard care supplemented by the application of the LeucoPatch® device. The primary outcome will be the percentage of ulcers healed within 20 weeks. Healing will be defined as complete epithelialisation without discharge that is maintained for 4 weeks and is confirmed by an observer blind to randomisation group. Ulcers of the foot are a major source of morbidity to patients with diabetes and costs to health care economies. The study population is designed to be as inclusive as possible with the aim of maximising the external validity of any findings. The primary outcome measure is healing within 20 weeks of randomisation and the trial also includes a number of secondary outcome measures. Among these are rate of change in ulcer area as a predictor of the likelihood of eventual healing, minor and major amputation of the target limb, the incidence of infection and quality of life. International Standard Randomised Controlled Trial, ISRCTN27665670 . Registered on 5 July 2013.
Mehdizadeh, M. Reza; Weng, Hong; Gyawali, Dipendra; Tang, Liping; Yang, Jian
2012-01-01
The existing surgical adhesives are not ideal for wet tissue adhesion required in many surgeries such as those for internal organs. Developing surgical adhesives with strong wet tissue adhesion, controlled degradability and mechanical properties, and excellent biocompatibility has been a significant challenge. Herein, learning from nature, we report a one-step synthesis of a family of injectable citrate-based mussel-inspired bioadhesives (iCMBAs) for surgical use. Within the formulations investigated, iCMBAs showed 2.5–8.0 folds stronger wet tissue adhesion strength over the clinically used fibrin glue, demonstrated controlled degradability and tissue-like elastomeric mechanical properties, and exhibited excellent cyto/tissue-compatibility both in vitro and in vivo. iCMBAs were able to stop bleeding instantly and suturelessly, and close wounds (2 cm long × 0.5 cm deep) created on the back of Sprague-Dawley rats, which is impossible when using existing gold standard, fibrin glue, due to its weak wet tissue adhesion strength. Equally important, the new bioadhesives facilitate wound healing, and are completely degraded and absorbed without eliciting significant inflammatory response. Our results support that iCMBA technology is highly translational and could have broad impact on surgeries where surgical tissue adhesives, sealants, and hemostatic agents are used. PMID:22902057
Fibrin Sealant Improves Hemostasis in Peripheral Vascular Surgery: A Randomized Prospective Trial
Schenk, Worthington G.; Burks, Sandra G.; Gagne, Paul J.; Kagan, Steven A.; Lawson, Jeffrey H.; Spotnitz, William D.
2003-01-01
Objective To evaluate the efficacy and safety of an investigational fibrin sealant (FS) in a randomized prospective, partially blinded, controlled, multicenter trial. Summary Background Data Upper extremity vascular access surgery using polytetrafluorethylene (PTFE) graft placement for dialysis was chosen as a reproducible, clinically relevant model for evaluating the usefulness of FS. The FS consisted of pooled human fibrinogen (60 mg/mL) and thrombin (500 NIH U/mL). Time to hemostasis was measured, and adverse events were monitored. Methods Consenting adult patients (n = 48) undergoing placement of a standard PTFE graft were randomized in a 2:1:1 ratio to the treatment group using FS (ZLB Bioplasma AG, Bern, Switzerland), oxidized regenerated cellulose (Surgicel, Johnson & Johnson, New Brunswick, NJ), or pressure. Patients received heparin (3,000 IU IVP) before placement of vascular clamps. If the treatment was FS, clamps were left in place for 120 seconds after the application of study material to permit polymerization. If treatment was Surgicel, clamps were left in place until the agent had been applied according to manufacturer’s instructions. If the treatment was pressure, clamps were released as soon as the investigator was ready to apply compression. Immediately after release of the last clamp, the arterial and venous suture lines were evaluated for bleeding. The time to hemostasis at both the venous and arterial sites was recorded. Results Significant (P ≤ .005) reduction in time to hemostasis was achieved in the FS group. Thirteen (54.2%) patients randomized to FS experienced immediate hemostasis at both suture lines following clamp removal compared to no patients using Surgicel or pressure. Only one patient (7.1%) in the Surgicel group and no patients in the pressure group experienced hemostasis at 120 seconds from clamp removal, compared to 13 (54.2%) patients for FS. Adverse events were comparable in all groups. There were no seroconversions. Conclusions FS achieved more rapid hemostasis than traditional techniques in this peripheral vascular procedure. FS use appeared to be safe for this procedure. PMID:12796584
Schmidlin, Patrick R; Seemann, Rainer; Filli, Tilla; Attin, Thomas; Imfeld, Thomas
2007-01-01
A laboratory study was performed to assess the potential of an adhesive patch to seal small, unbeveled, Class II, box-only (slot) composite fillings. After minimal access cavity preparation with an 80 pm diamond bur, 40 box-only Class II cavities were prepared mesially and distally in 20 extracted human molars using a u-shaped PCS insert (EMS). One cavity per tooth was adhesively filled with a hybrid composite material in one increment. A patch, acting as an adhesive matrice, was applied to the other cavity of each tooth to seal the restoration. The margin of the patch was located in areas easily accessible to oral hygiene measures and self-cleaning. All the teeth were subjected to thermo-mechanical stress in a computer-controlled masticator device. In 10 teeth, caries was induced in a microbial-based artificial mouth model and quantitatively determined by confocal laser scanning microscopy. Microleakage was assessed in the other 10 teeth in two planar sections after immersion in 0.5% basic fuchsin solution. The results showed no demineralization at the filling margins protected with the patch. Microleakage was observed in one sample only and was limited to the enamel. In contrast, the margins of fillings without the patch application showed a mean demineralization depth of 146 +/- 42 microm and dye penetration into the dentin in five sections. This innovative approach to sealing restorative margins with an adhesive patch results in less leakage and filling margin demineralization and merits further investigation.
Sutureless amniotic membrane transplantation for partial limbal stem cell deficiency.
Kheirkhah, Ahmad; Casas, Victoria; Raju, Vadrevu K; Tseng, Scheffer C G
2008-05-01
To evaluate the results of sutureless amniotic membrane (AM) transplantation using fibrin glue for reconstructing corneal surfaces with partial limbal stem cell deficiency (LSCD). Retrospective noncomparative interventional case series. Eleven eyes of nine patients that had LSCD with 120 degrees to almost 360 degrees of limbal involvement underwent superficial keratectomy to remove the conjunctivalized pannus followed by AM transplantation using fibrin glue. Additional sutureless AM patch (ProKera; Bio-Tissue, Inc, Miami, Florida, USA) was used in seven patients, and mitomycin C was applied on the cornea in four eyes and during fornix reconstruction in seven eyes. The surgery was repeated in three eyes for residual pannus. During a mean follow-up of 14.2 +/- 7.7 months (range, six to 26 months), all eyes maintained a smooth and stable corneal epithelial surface without recurrent erosion or persistent epithelial defect, and showed less stromal cloudiness and vascularization. Best-corrected visual acuity improved in nine eyes (81.8%). Corneal epithelialization proceeded by epithelial growth over AM (n = 4), accompanied by dissolution of AM (n = 4) or a combination of both (n = 3). No complication was noted regarding initial or repeated uses of fibrin glue. AM transplantation using fibrin glue appears to be a safe and effective method of restoring a stable corneal epithelium for cases with partial LSCD. This approach avoids the need of transplanting limbal epithelial stem cells.
Polymers Advance Heat Management Materials for Vehicles
NASA Technical Reports Server (NTRS)
2013-01-01
For 6 years prior to the retirement of the Space Shuttle Program, the shuttles carried an onboard repair kit with a tool for emergency use: two tubes of NOAX, or "good goo," as some people called it. NOAX flew on all 22 flights following the Columbia accident, and was designed to repair damage that occurred on the exterior of the shuttle. Bill McMahon, a structural materials engineer at Marshall Space Flight Center says NASA needed a solution for the widest range of possible damage to the shuttle s exterior thermal protection system. "NASA looked at several options in early 2004 and decided on a sealant. Ultimately, NOAX performed the best and was selected," he says. To prove NOAX would work effectively required hundreds of samples manufactured at Marshall and Johnson, and a concerted effort from various NASA field centers. Johnson Space Center provided programmatic leadership, testing, tools, and crew training; Glenn Research Center provided materials analysis; Langley Research Center provided test support and led an effort to perform large patch repairs; Ames Research Center provided additional testing; and Marshall provided further testing and the site of NOAX manufacturing. Although the sealant never had to be used in an emergency situation, it was tested by astronauts on samples of reinforced carbon-carbon (RCC) during two shuttle missions. (RCC is the thermal material on areas of the shuttle that experience the most heat, such as the nose cone and wing leading edges.) The material handled well on orbit, and tests showed the NOAX patch held up well on RCC.
Fibrin-genipin annulus fibrosus sealant as a delivery system for anti-TNFα drug.
Likhitpanichkul, Morakot; Kim, Yesul; Torre, Olivia M; See, Eugene; Kazezian, Zepur; Pandit, Abhay; Hecht, Andrew C; Iatridis, James C
2015-09-01
Intervertebral discs (IVDs) are attractive targets for local drug delivery because they are avascular structures with limited transport. Painful IVDs are in a chronic inflammatory state. Although anti-inflammatories show poor performance in clinical trials, their efficacy treating IVD cells suggests that sustained, local drug delivery directly to painful IVDs may be beneficial. The purpose of this study was to determine if genipin cross-linked fibrin (FibGen) with collagen Type I hollow spheres (CHS) can serve as a drug-delivery carrier for infliximab, the anti-tumor necrosis factor α (TNFα) drug. Infliximab was chosen as a model drug because of the known role of TNFα in increasing downstream production of several pro-inflammatory cytokines and pain mediators. Genipin cross-linked fibrin was used as drug carrier because it is adhesive, injectable, and slowly degrading hydrogel with the potential to seal annulus fibrosus (AF) defects. CHS allow simple and nondamaging drug loading and could act as a drug reservoir to improve sustained delivery. This is a study of biomaterials and human AF cell culture to determine drug release kinetics and efficacy. Infliximab was delivered at low and high concentrations using FibGen with and without CHS. Gels were analyzed for structure, drug release kinetics, and efficacy treating human AF cells after release. Fibrin showed rapid infliximab drug release but degraded quickly. CHS alone showed a sustained release profile, but the small spheres may not remain in a degenerated IVD with fissures. Genipin cross-linked fibrin showed steady and low levels of infliximab release that was increased when loaded with higher drug concentrations. Infliximab was bound in CHS when delivered within FibGen and was only released after enzymatic degradation. The infliximab released over 20 days retained its bioactivity as confirmed by the sustained reduction of interleukin (IL)-1β, IL-6, IL-8, and TNFα concentrations produced by AF cells. Direct mixing of infliximab into FibGen was the simplest drug-loading protocol capable of sustained release. Results show feasibility of using drug-loaded FibGen for delivery of infliximab and, in the context with the literature, show potential to seal AF defects and partially restore IVD biomechanics. Future investigations are required to determine if drug-loaded FibGen can effectively deliver drugs, seal AF defects, and promote IVD repair or prevent further IVD degeneration in vivo. Copyright © 2015 Elsevier Inc. All rights reserved.
Efficacy of Laser Photobiomodulation on Morphological and Functional Repair of the Facial Nerve.
Buchaim, Daniela Vieira; Andreo, Jesus Carlos; Ferreira Junior, Rui Seabra; Barraviera, Benedito; Rodrigues, Antonio de Castro; Macedo, Mariana de Cássia; Rosa Junior, Geraldo Marco; Shinohara, Andre Luis; Santos German, Iris Jasmin; Pomini, Karina Torres; Buchaim, Rogerio Leone
2017-08-01
Evaluate the efficacy of low-level laser therapy (LLLT) on qualitative, quantitative, and functional aspects in the facial nerve regeneration process. Forty-two male Wistar rats were used, randomly divided into a control group (CG; n = 10), in which the facial nerve without lesion was collected, and four experimental groups: (1) suture experimental group (SEG) and (2) fibrin experimental group (FEG), consisting of 16 animals in which the buccal branch of the facial nerve was sectioned on both sides of the face; an end-to-end epineural suture was performed on the right side, and a fibrin sealant was used on the left side for coaptation of the stumps; and (3) laser suture experimental group (LSEG) and (4) laser fibrin experimental group (LFEG), consisting of 16 animals that underwent the same surgical procedures as SEG and FEG with the addition of laser application at three different points along the surgical site (pulsed laser of 830 nm wavelength, optical output power of 30 mW, power density of 0.2586 W/cm 2 , energy density of 6.2 J/cm 2 , beam area of 0.116 cm 2 , exposure time of 24 sec per point, total energy per session of 2.16 J, and cumulative dose of 34.56 J). The animals were submitted to functional analysis (subjective observation of whisker movement) and the data obtained were compared using Fisher's exact test. Euthanasia was performed at 5 and 10 weeks postoperative. The total number and density of regenerated axons were analyzed using the unpaired t-test (p < 0.05). Laser therapy resulted in a significant increase in the number and density of regenerated axons. The LSEG and LFEG presented better scores in functional analysis in comparison with the SEG and FEG. LLLT enhanced axonal regeneration and accelerated functional recovery of the whiskers, and both repair techniques allowed the growth of axons.
Comparison between electrocautery and fibrin selant after hepatectomy in rats.
Coutinho, Tâmara Rúbia Cavalcante Guimarães; Malafaia, Osvaldo; Torres, Orlando Jorge Martins; Ribas Filho, Jurandir Marcondes; Kaminski, Alvaro Fonseca; Cella, Igor Furlan; Jurkonis, Leandro Bressianini
2014-01-01
To compare between electrocautery and fibrin sealant hemostasis in rats after partial hepatectomy. we used 24 Wistar rats, which were submitted to 30% hepatic resection, divided into two groups of 12 animals each: Group Electrocautery and Group Tachosil(r). These animals were evaluated after three and 14 days. We assessed the presence of complications, laboratory tests and histological exam of the recovered liver. the presence of abscess was more prevalent in the electrocautery group. The observed adhesions were more pronounced in the electrocautery group, both in frequency and in intensity, after three and 14 days. There were no deaths in either group. As for laboratory analysis, after three days the hematocrit was lower in the TachoSil(r) Group. The elevation of AST and ALT were more pronounced in the electrocautery group (p = 0.002 and p = 0.004) in three days. Histological analysis of specimens collected on the third day after surgery showed similar results in both groups for the presence of polymorphonuclear cells, whereas mononuclear was more evident in the TachoSil(r) group. We also observed that angiogenesis, although present in both groups, was more pronounced in the TachoSil(r) group (p = 0.030). However, on the 14th day angiogenesis was more pronounced in the electrocautery group, but without statistical significance. hemostasis achieved by the groups was similar; however, the use of electrocautery was associated with infections, adhesions at higher grades and elevated liver enzymes.
Gao, Ling; Gregorich, Zachery R; Zhu, Wuqiang; Mattapally, Saidulu; Oduk, Yasin; Lou, Xi; Kannappan, Ramaswamy; Borovjagin, Anton V; Walcott, Gregory P; Pollard, Andrew E; Fast, Vladimir G; Hu, Xinyang; Lloyd, Steven G; Ge, Ying; Zhang, Jianyi
2018-04-17
Here, we generated human cardiac muscle patches (hCMPs) of clinically relevant dimensions (4 cm × 2 cm × 1.25 mm) by suspending cardiomyocytes, smooth muscle cells, and endothelial cells that had been differentiated from human induced-pluripotent stem cells in a fibrin scaffold and then culturing the construct on a dynamic (rocking) platform. In vitro assessments of hCMPs suggest maturation in response to dynamic culture stimulation. In vivo assessments were conducted in a porcine model of myocardial infarction (MI). Animal groups included: MI hearts treated with 2 hCMPs (MI+hCMP, n=13), MI hearts treated with 2 cell-free open fibrin patches (n=14), or MI hearts with neither experimental patch (n=15); a fourth group of animals underwent sham surgery (Sham, n=8). Cardiac function and infarct size were evaluated by MRI, arrhythmia incidence by implanted loop recorders, and the engraftment rate by calculation of quantitative polymerase chain reaction measurements of expression of the human Y chromosome. Additional studies examined the myocardial protein expression profile changes and potential mechanisms of action that related to exosomes from the cell patch. The hCMPs began to beat synchronously within 1 day of fabrication, and after 7 days of dynamic culture stimulation, in vitro assessments indicated the mechanisms related to the improvements in electronic mechanical coupling, calcium-handling, and force generation, suggesting a maturation process during the dynamic culture. The engraftment rate was 10.9±1.8% at 4 weeks after the transplantation. The hCMP transplantation was associated with significant improvements in left ventricular function, infarct size, myocardial wall stress, myocardial hypertrophy, and reduced apoptosis in the periscar boarder zone myocardium. hCMP transplantation also reversed some MI-associated changes in sarcomeric regulatory protein phosphorylation. The exosomes released from the hCMP appeared to have cytoprotective properties that improved cardiomyocyte survival. We have fabricated a clinically relevant size of hCMP with trilineage cardiac cells derived from human induced-pluripotent stem cells. The hCMP matures in vitro during 7 days of dynamic culture. Transplantation of this type of hCMP results in significantly reduced infarct size and improvements in cardiac function that are associated with reduction in left ventricular wall stress. The hCMP treatment is not associated with significant changes in arrhythmogenicity. © 2017 American Heart Association, Inc.
Beitzel, Knut; Chowaniec, David M; McCarthy, Mary Beth; Cote, Mark P; Russell, Ryan P; Obopilwe, Elifho; Imhoff, Andreas B; Arciero, Robert A; Mazzocca, Augustus D
2012-05-01
Rotator cuff reconstructions may be improved by adding growth factors, cells, or other biologic factors into the repair zone. This usually requires a biological carrier (scaffold) to be integrated into the construct and placed in the area of tendon-to-bone healing. This needs to be done without affecting the constructs mechanics. Hypothesis/ The hypothesis was that scaffold placement, as an interposition, has no adverse effects on biomechanical properties of double-row rotator cuff repair. The purpose of this study was to examine the effect of scaffold interposition on the initial strength of rotator cuff repairs. Controlled laboratory study. Twenty-five fresh-frozen shoulders (mean age: 65.5 ± 8.9 years) were randomly assigned to 5 groups. Groups were chosen to represent a broad spectrum of commonly used scaffold types: (1) double-row repair without augmentation, (2) double-row repair with interposition of a fibrin clot (Viscogel), (3) double-row repair with interposition of a collagen scaffold (Mucograft) between tendon and bone, (4) double-row repair with interposition of human dermis patch (ArthroFlex) between tendon and bone, and (5) double-row repair with human dermis patch (ArthroFlex) placed on top of the repair. Cyclic loading to measure displacement was performed to 3000 cycles at 1 Hz with an applied 10- to 100-N load. The ultimate load to failure was determined at a rate of 31 mm/min. There were no significant differences in mean displacement under cyclic loading, slope, or energy absorbed to failure between all groups (P = .128, P = .981, P = .105). Ultimate load to failure of repairs that used the collagen patch as an interposition (573.3 ± 75.6 N) and a dermis patch on top of the reconstruction (575.8 ± 22.6 N) was higher compared with the repair without a scaffold (348.9 ± 98.8 N; P = .018 and P = .025). No significant differences were found for repairs with the fibrin clot as an interposition (426.9 ± 103.6 N) and the decellularized dermis patch as an interposition (469.9 ± 148.6 N; P = .73 and P = .35). Scaffold augmentation did not adversely affect the zero time strength of the tested standard double-row rotator cuff repairs. An increased ultimate load to failure was observed for 2 of the augmentation methods (collagen patch as an interposition and decellularized dermis patch on top of the reconstruction) compared with the nonaugmented repairs. Scaffolds intended for application of growth factors or cellular components in a repair situation did not adversely jeopardize the stability of the operative construct.
... this page: //medlineplus.gov/ency/patientinstructions/000779.htm Dental sealants To use the sharing features on this ... case a sealant needs to be replaced. How Dental Sealants are Applied Your dentist applies sealants on ...
Hemostatic Modifications of the Bentall Procedure
Della Corte, Alessandro; Baldascino, Francesco; La Marca, Francesca; Scardone, Michelangelo; Nappi, Gianantonio; Cefarelli, Mariano; De Santo, Luca S.; Pepino, Paolo; Cotrufo, Maurizio; De Feo, Marisa
2012-01-01
Bleeding is an important predictor of morbidity and mortality rates after the Bentall operation. This study reports our recent experience with composite aortic root replacement via a slightly modified button-Bentall operation. Fifty-six consecutive patients underwent a Bentall operation on an elective basis from January 2008 through December 2009. In all cases, we used 2 modifications: we imbricated the pledgeted 2-0 polyester interrupted U stitches of the proximal suture line, and at that same suture line we sealed with fibrin glue the possible sources of oozing. The series featured high proportions of associated procedures (25%) and reoperations (23%). The mean cardiopulmonary bypass and aortic cross-clamp times were 166 ± 50 and 113 ± 27 min, respectively. No case of operative or hospital (30-day) death was observed. Postoperative drainage amounted to 705 mL (median) on the first postoperative day and 377 mL (mean) on the second. Surgical re-exploration for bleeding was needed in only 1 patient (1.8%). Postoperative acute kidney injury was observed in 5 patients, neurologic complications in 3, and respiratory insufficiency requiring prolonged mechanical ventilation in another 3. Both respiratory and renal complications were significantly associated with greater consumption of blood products (P=0.03 and P=0.001, respectively). We conclude that the combined use of imbricated proximal suture-line stitches and subsequent fibrin-sealant spraying were associated with no deaths and with low rates of bleeding and other adverse postoperative sequelae in our 2-year experience with the Bentall operation in an elective series of patients characterized by a difficult mixture of prognoses. PMID:22740732
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bowley, S.; Okumura, N; Lord, S
'A:a' knob-hole interactions and D:D interfacial interactions are important for fibrin polymerization. Previous studies with recombinant ?N308K fibrinogen, a substitution at the D:D interface, showed impaired polymerization. We examined the molecular basis for this loss of function by solving the crystal structure of ?N308K fragment D. In contrast to previous fragment D crystals, the ?N308K crystals belonged to a tetragonal space group with an unusually long unit cell (a = b = 95 Angstroms, c = 448.3 Angstroms). Alignment of the normal and ?N308K structures showed the global structure of the variant was not changed and the knob 'A' peptidemore » GPRP was bound as usual to hole 'a'. The substitution introduced an elongated positively charged patch in the D:D region. The structure showed novel, symmetric D:D crystal contacts between ?N308K molecules, indicating the normal asymmetric D:D interface in fibrin would be unstable in this variant. We examined GPRP binding to ?N308K in solution by plasmin protection assay. The results showed weaker peptide binding, suggesting that 'A:a' interactions were altered. We examined fibrin network structures by scanning electron microscopy and found the variant fibers were thicker and more heterogeneous than normal fibers. Considered together, our structural and biochemical studies indicate both 'A:a' and D:D interactions are weaker. We conclude that stable protofibrils cannot assemble from ?N308K monomers, leading to impaired polymerization.« less
West, Nathan G; Ilief-Ala, Melina A; Douglass, Joanna M; Hagadorn, James I
2011-01-01
This study's purpose was to determine whether one-time sealants placed by pediatric dental residents vs dental students have different outcomes. The effect of isolation technique, behavior, duration of follow-up, and caries history was also examined. Records from 2 inner-city pediatric dental clinics were audited for 6- to 10-year-old patients with a permanent first molar sealant with at least 2 years of follow-up. A successful sealant was a one-time sealant that received no further treatment and was sealed or unsealed but not carious or restored at the final audit. Charts from 203 children with 481 sealants were audited. Of these, 281 sealants were failures. Univariate analysis revealed longer follow-up and younger age were associated with sealant failure. Operator type, child behavior, and isolation technique were not associated with sealant failure. After adjusting for follow-up duration, increased age at treatment reduced the odds of sealant failure while a history of caries reduced the protective effect of increased age. After adjusting for these factors, practitioner type, behavior, and type of isolation were not associated with sealant outcome in multivariate analysis. Age at sealant placement, history of caries prior to placement, and longer duration of follow-up are associated with sealant failure.
NASA Technical Reports Server (NTRS)
Rosser, R. W.; Parker, J. A.
1974-01-01
The status of high-temperature fuel tank sealants for military and potentially commercial supersonic aircraft is examined. The interrelationships of NASA's sealants program comprise synthesis and development of new fluoroether elastomers, sealant prediction studies, flight simulation and actual flight testing of best state-of-the-art fluorosilicone sealants. The technical accomplishments of these projects are reviewed.
Sealant Microleakage After Using Nano-Filled Bonding Agents on Saliva-Contaminated Enamel
Paryab, Mehrsa
2013-01-01
Objective: The efficacy of correctly applied fissure sealants has been revealed in the prevention of caries. Saliva and moisture contamination of the etched enamel surface before sealant placement can decrease the bonding strength of the sealant to the enamel. The aim of this study was to test the new bonding agents containing nano-fillers in order to reduce the negative effect of saliva contamination on the sealant micro leakage. Materials and Methods: Seventy five sound human premolars were randomly assigned to five equal groups as follows: Group A: etching, sealant; Group B: etching, saliva contamination, sealant; Group C: etching, saliva contamination, Single bond, sealant; Group D: etching, saliva contamination, Adper Single bond 2, sealant; Group E: etching, saliva contamination, N Bond, sealant. The samples were thermo-cycled and immersed in basic fuchsine 0.5% by weight. Then, the teeth were sectioned bucco-lingually and parallel to the long axis into two segments. Finally, the length of dye penetration at the sealant-tooth interface was scored according to a four-point scale. Results: Micro-leakage was higher in group B compared to the other groups, while there were no differences among the evaluated dentin adhesives. Conclusion: The use of nano-filled bonding agents as an intermediate layer between the etched enamel and the sealant can reduce sealant micro-leakage after saliva contamination at the level of the uncontaminated enamel. PMID:25512749
Laser fluorescence of dentin caries covered with a novel nano-filled sealant.
Braun, Andreas; Beisel, Christian; Brede, Olivier; Krause, Felix
2013-01-01
The aim of the present study was to assess the possibility to measure caries-induced laser fluorescence underneath a novel nano-filled fissure sealant. Sixty freshly extracted human teeth with occlusal dentine carious lesions were horizontally divided, exposing the respective lesion. Teeth were randomly assigned to three groups: (I) white fissure sealant with filler particles (Fissurit F, Voco), (II) clear fissure sealant without filler particles (Fissurit, Voco) and (III) novel experimental fissure sealant with nano-filler particles (Voco). Starting with a sealant thickness of 3 mm, laser fluorescence measurements (DIAGNOdent, KaVo) were performed after finishing the sealant surfaces with polishing papers, reducing the material at intervals of 0.5 mm until the sealant was removed completely. Evaluating a thickness of 0.5 mm, both the clear (83 % of the baseline fluorescence after fine grit polishing) and the white sealant (25 %) did not allow to measure baseline fluorescence (p < 0.05) with no fluorescence reduction in the experimental sealant group (p > 0.05). With increasing sealer thickness, fluorescence was influenced even by the experimental material (89 % of the baseline value at 1 mm). However, by using the experimental material, statistically significant higher fluorescence values than those for the other materials under study (p < 0.05) were obtained. Thicker sealant layers and coarse grit polishing caused a decrease of laser fluorescence in all groups (p < 0.05). Employing the experimental nano-filled sealant, laser fluorescence measurements for caries detection can be performed through thicker sealant layers compared to conventional sealant materials. Thus, it might be possible to use this material to assess a caries progression underneath the sealant and administer an appropriate therapy in due time.
Pedroso, Lauana Borges; Barreto, Luma Franciélle Cabreira; Miotti, Leonardo Lamberti; Nicoloso, Gabriel Ferreira; Durand, Leticia Brandão
2016-01-01
This study evaluated the influence of surface sealants on the color stability of 2 different composite resins after immersion in coffee. Four groups were created (n = 10): microhybrid composite, microhybrid with surface sealant, nanofilled composite, and nanofilled composite with surface sealant. Half of the specimens of each group were immersed in distilled water and half were immersed in coffee for 48 hours. Color was measured before and after immersion. Groups with surface sealants presented less color variation when compared with the groups without surface sealants. The nanofilled resin specimens presented the greatest color variation within the groups without sealant. The surface sealant positively influenced the color stability of composite resin specimens immersed in coffee. When surface sealant was not applied, the microhybrid specimens had better color stability than the nanofilled.
2014-01-01
Background The relative performance of ART sealant and fluoride-releasing resin sealant in preventing fissure caries in permanent molars was compared in a randomized clinical trial conducted in southern China (ClinicalTrials.gov NCT01829334). Methods After obtaining ethical approval, healthy schoolchildren who had permanent first molars with occlusal fissures which were sound but deep or presented with only incipient caries were recruited for the study. Included molars were randomly allocated into one of four parallel study groups in units of left/right teeth per mouth. Two of the four groups adopted the methods of ART or fluoride-releasing resin sealant placement while the other two groups adopted the topical fluoride application methods. Fissure status of the molars in each group was evaluated every 6 months. Development of dentine caries and sealant retention over 24 months in the molars in the two sealant-using groups was compared in this report. Outcome on cost-effectiveness of all four groups over 36 months will be reported elsewhere. Results At baseline, a total of 280 children (383 molars) with mean age 7.8 years were involved for the two sealant groups. After 24 months, 261 children (357 molars) were followed. Proportions of molars with dentine caries were 7.3% and 3.9% in the ART sealant and fluoride-releasing resin sealant groups, respectively (chi-square test, p = 0.171). Life-table survival analysis showed that sealant retention (full and partial) rate over 24 months for the resin sealant (73%) was significantly higher than that (50%) for the ART sealant (p < 0.001). Molar survival (no development of dentine caries) rates in the ART sealant (93%) and fluoride-releasing resin sealant (96%) groups were not significantly different (p = 0.169). Multilevel logistic regression (GEE modeling) accounting for the effects of data clustering and confounding factors confirmed this finding. Conclusions Though the retention of fluoride-releasing resin sealant was better than that of the ART sealant, their effectiveness in preventing fissure caries in permanent molars did not differ significantly over 24 months. ART sealants could be a good alternative when and where resources for resin sealant placement are not readily available. PMID:24886444
New Joint Sealants. Criteria, Design and Materials.
ERIC Educational Resources Information Center
Building Research Inst., Inc., Washington, DC.
Contents include--(1) sealing concrete joints, (2) sealing glass and metal joints, (3) metal and glass joint sealants from a fabricator's viewpoint, (4) a theory of adhesion for joint sealants, (5) geometry of simple joint seals under strain, (6) joint sealant specifications from a manufacturer's viewpoint, (7) joint sealant requirements from an…
Bond strength of Bis-GMA and glass ionomer pit and fissure sealants using cyclic fatigue.
Dewji, H R; Drummond, J L; Fadavi, S; Punwani, I
1998-02-01
The aim of the study was to determine the bond strength of glass ionomer and resin-modified glass ionomer sealants compared to Bis-GMA sealants using both static and cyclic fatigue shear testing. Four materials were evaluated: D, a Bis-GMA sealant with 10% phosphoric acid etchant; FC, a resin-modified glass ionomer sealant with 20% polyacrylic acid etchant; FD, a resin-modified glass ionomer sealant with 10% polyacrylic acid etchant; and FSC, a self-cured glass ionomer sealant with no etchant. Gelatin capsules filled with the sealant material were bonded to the enamel surfaces of bovine teeth after appropriate surface conditioning and then tested in shear static and cyclic fatigue. Static and cyclic shear bond strengths, respectively, for each group were (MPa): FC: 21.1+/-2.8 and 17.1+/-3.1; FD: 14.6+/-5.9 and 8.5+/-3.1; D: 10.8+/-4.9 and 4.7+/-2.6; FSC: 8.7 (1.0 and 2.9+/-0.6. The resin-modified glass ionomer sealants had better fatigue bond strength than both Bis-GMA and self-cured glass ionomer sealants with the surface conditioning affecting the bond strength of the resin-modified glass ionomer sealants.
Glass ionomer ART sealants in Chinese school children-6-year results.
Holmgren, Christopher J; Lo, Edward C M; Hu, Deyu
2013-09-01
To evaluate longitudinally ART sealants placed in Chinese school children under field conditions. 191 ART sealants were placed in 140 children, aged 11-14 years, by five assistant dentists in four secondary schools in Deyang, Sichuan Province, China. Teeth selected for sealing were those with pits and fissures that were deep or showing early enamel caries. Teeth were excluded if there was obvious cavitation extending into dentine. Standard instruments and procedures for ART sealants were used. The material used was a high-viscosity glass-ionomer (Ketac-Molar, 3MESPE) that was inserted into the pits and fissures with the "press-finger" technique. The status of the sealants was evaluated annually over 6 years after placement by the same examiner who was not involved in the placement of the sealants using explorers, mouth-mirrors and an intra-oral fibre-optic light. No missing sealants were replaced during the study. 107 sealants (56% of the original) were examined after 6 years. The cumulative survival rates of the sealants (partially or fully retained) after 2, 4 and 6 years were 79%, 68% and 59%, respectively. Caries prevention lagged the fall in sealant survival but remained high throughout the study period, being over 90% in the first 4 years and 85% after 6 years. ART sealants placed under field conditions in Chinese schoolchildren have a high retention rate. Missing sealants should be replaced to maintain their preventive efficacy. The sealing of pits and fissures can be an effective caries preventive approach. Resin-based sealants have the disadvantage in that they require an optimal level of moisture control during placement. In children and in outreach situations glass ionomer ART sealants, which are more moisture tolerant, can offer a viable alternative. Copyright © 2013 Elsevier Ltd. All rights reserved.
Chi, Donald L; Singh, Jennifer
2013-11-01
Little is known about Medicaid policies regarding reimbursement for placement of sealants on primary molars. The authors identified Medicaid programs that reimbursed dentists for placing primary molar sealants and hypothesized that these programs had higher reimbursement rates than did state programs that did not reimburse for primary molar sealants. The authors obtained Medicaid reimbursement data from online fee schedules and determined whether each state Medicaid program reimbursed for primary molar sealants (no or yes). The outcome measure was the reimbursement rate for permanent tooth sealants (calculated in 2012 U.S. dollars). The authors compared mean reimbursement rates by using the t test (α = .05). Seventeen Medicaid programs reimbursed dentists for placing primary molar sealants (34 percent), and the mean reimbursement rate was $27.57 (range, $16.00 [Maine] to $49.68 [Alaska]). All 50 programs reimbursed dentists for placement of sealants on permanent teeth. The mean reimbursement for permanent tooth sealants was significantly higher in programs that reimbursed for primary molar sealants than in programs that did not ($28.51 and $23.67, respectively; P = .03). Most state Medicaid programs do not reimburse dentists for placing sealants on primary molars, but programs that do so have significantly higher reimbursement rates. Medicaid reimbursement rates are related to dentists' participation in Medicaid and children's dental care use. Reimbursement for placement of sealants on primary molars is a proxy for Medicaid program generosity.
Ability Of Optical Coherence Tomography To Detect Caries Beneath Commonly Used Dental Sealants
Osann, Kathryn; Pharar, Jessica; Lee, Kenneth; Ahn, Yeh-chan; Tucker, Travis; Sabet, Sharareh; Chen, Zhongping; Gukasyan, Ripsik; Wilder-Smith, Petra
2010-01-01
Background and Objective The onset and progression of early tooth decay is often preventable with dental sealants. However, occasionally decay progresses underneath the sealant. Current technology does not permit monitoring of potential lesion progression or arrest. Dental sealants themselves mask the visual cues that identify early tooth decay, and radiographs are not sufficiently sensitive. Therefore clinicians can be reluctant to use dental sealant. The objective of this ex vivo study was to evaluate the ability of dentists to detect decay beneath commonly used dental sealants using Optical Coherence Tomography (OCT) imaging. Study Designs/Materials/Methods Forty extracted teeth were divided into equal groups of carious and non-carious teeth, as determined by visual inspection. After radiographs and OCT imaging, teeth were randomly assigned for sealant placement with one of four commonly purchased dental sealants: Clinpro™, Fuji Triage™, Embrace Wet Bond™, and Delton™. Following sealant placement, teeth were radiographed, imaged with OCT, sectioned, examined histologically, and scored as healthy/not healthy. OCT and radiographic images were scored separately. The gold standard was histopathological diagnosis from the serial sections. Cohen’s Kappa, sensitivity, negative predictive value and positive predictive value were computed for all measures. Results After 90 mins training, pre-standardized dentists were able to detect tooth decay more accurately using OCT than with visual or radiographic examination. Detection using OCT was somewhat better prior to sealant placement than afterwards. This effect varied in size depending on the type of sealant used. Radiographic diagnosis was also less accurate after sealant placement. Of the four dental sealants, Delton provided excellent positive predictive value and the best post-sealant negative predictive values. Conclusion In this ex vivo study, dentists were able to detect tooth decay beneath four commonly used dental sealants based on OCT images. Clinical investigations are now underway to determine the usefulness of this approach in vivo. PMID:20848554
Microleakage of self-etching sealant on noncontaminated and saliva-contaminated enamel.
2011-01-01
The purpose of this study was to compare the microleakage of a self-etching sealant with a traditional phosphoric acid-etched sealant under noncontaminated and saliva-contaminated conditions. Fifty-two sound extracted human molars were randomly divided into 4 groups (N=13). Teeth in Groups 1 and 2 were cleaned with pumice, etched with phosphoric acid, rinsed, coated with a drying agent, placed with sealants (UltraSeal XT Plus), and light cured. Teeth in Groups 3 and 4 were cleaned with a proprietary flour pumice and rinsed prior to being sealed with a self-etching sealant (Enamel Loc). Teeth in Groups 2 and 4 were contaminated with saliva and thoroughly air-dried prior to the sealant placement. All teeth were subjected to a thermocycling process, stained with silver nitrate, and sectioned, and images of the sealant on the occlusal surface were recorded. Microleakage distance was measured in millimeters and subjected to a 2-way analysis of variance. Significantly larger microleakage distances were found for the self-etching sealant vs the traditional sealant (P<.001). Saliva contamination did not significantly affect the microleakage distance (P<.17). Under the conditions used in this in vitro study, the self-etching sealant, regardless of contamination condition, had extensive microleakage distances vs. little microleakage in the traditional phosphoric acid-etched sealant.
Dental Sealants Prevent Cavities
... Digital Press Kit Read the MMWR Science Clips Dental Sealants Prevent Cavities Effective protection for children Language: ... more use of sealants and reimbursement of services. Dental care providers can Apply sealants to children at ...
Epstein, Nancy E
2015-01-01
Typically, fibrin sealants (FSs) and fibrin glues (FGs) are used to strengthen dural repairs during spinal surgery. In 2014, Epstein demonstrated that one FS/FG, Tisseel (Baxter International Inc., Westlake Village, CA, USA) equalized the average times to drain removal and length of stay (LOS) for patients with versus without excess bleeding (e.g. who did not receive Tisseel) undergoing multilevel laminectomies with 1-2 level noninstrumented fusions (LamF).[6]. Here Tisseel was utilized to promote hemostasis for two populations; 39 patients undergoing average 4.4 level lumbar laminectomies with average 1.3 level noninstrumented fusions (LamF), and 48 patients undergoing average 4.0 level laminectomies alone (Lam). We compared the average operative time, estimated blood loss (EBL), postoperative drainage, LOS, and transfusion requirements for the LamF versus Lam groups. The average operative times, EBL, postoperative drainage, LOS, and transfusion requirements were all greater for LamF versus Lam patients; operative times (4.1 vs. 3.0 h), average EBL (192.3 vs. 147.9 cc), drainage (e.g. day 1; 199.6 vs. 167.4 cc; day 2; 172.9 vs. 63.9 cc), average LOS (4.6 vs. 2.5 days), and transfusion requirements (11 LamF patients; 18 Units [U] RBC versus 2 Lam patients; 3 U RBC). Utilizing Tisseel to facilitate hemostasis in LamF versus Lam still resulted in greater operative times, EBL, postoperative average drainage, LOS, and transfusion requirements for patients undergoing the noninstrumented fusions. Although Tisseel decreases back bleeding within the spinal canal, it does not reduce blood loss from LamF decorticated transverse processes.
Tisseel utilized as hemostatic in spine surgery impacts time to drain removal and length of stay.
Epstein, Nancy E
2014-01-01
Although fibrin sealants (FSs) and fibrin glues (FGs) are predominantly utilized to strengthen repairs of cerebrospinal fluid (CSF) fistulas (deliberate/traumatic) during spinal surgery, they are also increasingly utilized to achieve hemostasis. Here, we investigated whether adding Tisseel (Baxter International Inc., Westlake Village, CA, USA), utilized to address increased bleeding during multilevel lumbar laminectomies with non-instrumented fusions, would reduce or equalize the time to drain removal and length of stay (LOS) without contributing to infections or prolonging time to fusion. Prospectively, 39 patients underwent multilevel laminectomies and 1-2 level non-instrumented (in situ) fusions to address stenosis/olisthesis; 22 who demonstrated increased intraoperative bleeding received Tisseel, while 17 without such bleeding did not. The 22 receiving versus 17 not receiving Tisseel, with similar clinical parameters, underwent comparable average multilevel laminectomies (4.36 and 4.25) and 1-2 level fusions (1.4 vs. 1.29 levels). As anticipated, for those receiving Tisseel, the average intraoperative estimated blood loss (EBL), total postoperative blood loss, and total perioperative transfusion requirements [red blood cells (RBC), fresh frozen plasma (FFP), platelets] were higher. However, Tisseel had the added benefit of equalizing the time to postoperative drain removal [e.g. 3.41 days (with) vs. 3.38 days (without)] and LOS [e.g. 5.86 days (with) vs. 5.82 days (without)] without increasing the infection rates (e.g. one superficial infection per group) or average times to fusion (e.g. 5.9 vs. 5.5 months). Adding Tisseel for increased bleeding during multilevel laminectomies/in situ fusions contributed to hemostasis by equalizing the average times to drain removal/LOS compared to patients without increased bleeding and not requiring Tisseel.
Methods to decrease blood loss during liver resection: a network meta-analysis.
Moggia, Elisabetta; Rouse, Benjamin; Simillis, Constantinos; Li, Tianjing; Vaughan, Jessica; Davidson, Brian R; Gurusamy, Kurinchi Selvan
2016-10-31
Liver resection is a major surgery with significant mortality and morbidity. Specialists have tested various methods in attempts to limit blood loss, transfusion requirements, and morbidity during elective liver resection. These methods include different approaches (anterior versus conventional approach), use of autologous blood donation, cardiopulmonary interventions such as hypoventilation, low central venous pressure, different methods of parenchymal transection, different methods of management of the raw surface of the liver, different methods of vascular occlusion, and different pharmacological interventions. A surgeon typically uses only one of the methods from each of these seven categories. The optimal method to decrease blood loss and transfusion requirements in people undergoing liver resection is unknown. To assess the effects of different interventions for decreasing blood loss and blood transfusion requirements during elective liver resection. We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, and Science Citation Index Expanded to September 2015 to identify randomised clinical trials. We also searched trial registers and handsearched the references lists of identified trials. We included only randomised clinical trials (irrespective of language, blinding, or publication status) comparing different methods of decreasing blood loss and blood transfusion requirements in people undergoing liver resection. Two review authors independently identified trials and collected data. We assessed the risk of bias using Cochrane domains. We conducted a Bayesian network meta-analysis using the Markov chain Monte Carlo method in WinBUGS 1.4, following the guidelines of the National Institute for Health and Care Excellence Decision Support Unit guidance documents. We calculated the odds ratios (OR) with 95% credible intervals (CrI) for the binary outcomes, mean differences (MD) with 95% CrI for continuous outcomes, and rate ratios with 95% CrI for count outcomes, using a fixed-effect model or random-effects model according to model-fit. We assessed the evidence with GRADE. We identified 67 randomised clinical trials involving a total of 6197 participants. All the trials were at high risk of bias. A total of 5771 participants from 64 trials provided data for one or more outcomes included in this review. There was no evidence of differences in most of the comparisons, and where there was, these differences were in single trials, mostly of small sample size. We summarise only the evidence that was available in more than one trial below. Of the primary outcomes, the only one with evidence of a difference from more than one trial under the pair-wise comparison was in the number of adverse events (complications), which was higher with radiofrequency dissecting sealer than with the clamp-crush method (rate ratio 1.85, 95% CrI 1.07 to 3.26; 250 participants; 3 studies; very low-quality evidence). Among the secondary outcomes, the only differences we found from more than one trial under the pair-wise comparison were the following: blood transfusion (proportion) was higher in the low central venous pressure group than in the acute normovolemic haemodilution plus low central venous pressure group (OR 3.19, 95% CrI 1.56 to 6.95; 208 participants; 2 studies; low-quality evidence); blood transfusion quantity (red blood cells) was lower in the fibrin sealant group than in the control (MD -0.53 units, 95% CrI -1.00 to -0.07; 122 participants; 2; very low-quality evidence); blood transfusion quantity (fresh frozen plasma) was higher in the oxidised cellulose group than in the fibrin sealant group (MD 0.53 units, 95% CrI 0.36 to 0.71; 80 participants; 2 studies; very low-quality evidence); blood loss (MD -0.34 L, 95% CrI -0.46 to -0.22; 237 participants; 4 studies; very low-quality evidence), total hospital stay (MD -2.42 days, 95% CrI -3.91 to -0.94; 197 participants; 3 studies; very low-quality evidence), and operating time (MD -15.32 minutes, 95% CrI -29.03 to -1.69; 192 participants; 4 studies; very low-quality evidence) were lower with low central venous pressure than with control. For the other comparisons, the evidence for difference was either based on single small trials or there was no evidence of differences. None of the trials reported health-related quality of life or time needed to return to work. Paucity of data meant that we could not assess transitivity assumptions and inconsistency for most analyses. When direct and indirect comparisons were available, network meta-analysis provided additional effect estimates for comparisons where there were no direct comparisons. However, the paucity of data decreases the confidence in the results of the network meta-analysis. Low-quality evidence suggests that liver resection using a radiofrequency dissecting sealer may be associated with more adverse events than with the clamp-crush method. Low-quality evidence also suggests that the proportion of people requiring a blood transfusion is higher with low central venous pressure than with acute normovolemic haemodilution plus low central venous pressure; very low-quality evidence suggests that blood transfusion quantity (red blood cells) was lower with fibrin sealant than control; blood transfusion quantity (fresh frozen plasma) was higher with oxidised cellulose than with fibrin sealant; and blood loss, total hospital stay, and operating time were lower with low central venous pressure than with control. There is no evidence to suggest that using special equipment for liver resection is of any benefit in decreasing the mortality, morbidity, or blood transfusion requirements (very low-quality evidence). Radiofrequency dissecting sealer should not be used outside the clinical trial setting since there is low-quality evidence for increased harm without any evidence of benefits. In addition, it should be noted that the sample size was small and the credible intervals were wide, and we cannot rule out considerable benefit or harm with a specific method of liver resection.
Pit and fissure sealants for preventing dental decay in permanent teeth.
Ahovuo-Saloranta, Anneli; Forss, Helena; Walsh, Tanya; Nordblad, Anne; Mäkelä, Marjukka; Worthington, Helen V
2017-07-31
Dental sealants were introduced in the 1960s to help prevent dental caries, mainly in the pits and fissures of occlusal tooth surfaces. Sealants act to prevent bacteria growth that can lead to dental decay. Evidence suggests that fissure sealants are effective in preventing caries in children and adolescents compared to no sealants. Effectiveness may, however, be related to caries incidence level of the population. This is an update of a review published in 2004, 2008 and 2013. To compare the effects of different types of fissure sealants in preventing caries in occlusal surfaces of permanent teeth in children and adolescents. Cochrane Oral Health's Information Specialist searched: Cochrane Oral Health's Trials Register (to 3 August 2016), the Cochrane Central Register of Controlled Trials (CENTRAL) (the Cochrane Library, 2016, Issue 7), MEDLINE Ovid (1946 to 3 August 2016), and Embase Ovid (1980 to 3 August 2016). We searched ClinicalTrials.gov and the World Health Organization International Clinical Trials Registry Platform for ongoing trials to 3 August 2016. No restrictions were placed on language or date of publication. Randomised controlled trials (RCTs) comparing sealants with no sealant or a different type of sealant material for preventing caries of occlusal surfaces of premolar or molar teeth in children and adolescents aged up to 20 years. Studies required at least 12 months follow-up. We excluded studies that compared compomers to resins/composites. Two review authors independently screened search results, extracted data and assessed risk of bias of included studies. We presented outcomes for caries or no caries on occlusal surfaces of permanent molar teeth as odds ratio (OR) or risk ratio (RR). We used mean difference (MD) for mean caries increment. All measures were presented with 95% confidence intervals (CI). We conducted meta-analyses using a random-effects model for comparisons where there were more than three trials; otherwise we used the fixed-effect model. We used GRADE methods to assess evidence quality. We included 38 trials that involved a total of 7924 children; seven trials were new for this update (1693 participants). Fifteen trials evaluated the effects of resin-based sealant versus no sealant (3620 participants in 14 studies plus 575 tooth pairs in one study); three trials with evaluated glass ionomer sealant versus no sealant (905 participants); and 24 trials evaluated one type of sealant versus another (4146 participants). Children were aged from 5 to 16 years. Trials rarely reported background exposure to fluoride of trial participants or baseline caries prevalence. Resin-based sealant versus no sealant: second-, third- and fourth-generation resin-based sealants prevented caries in first permanent molars in children aged 5 to 10 years (at 24 months follow-up: OR 0.12, 95% CI 0.08 to 0.19, 7 trials (5 published in the 1970s; 2 in the 2010s), 1548 children randomised, 1322 children evaluated; moderate-quality evidence). If we were to assume that 16% of the control tooth surfaces were decayed during 24 months of follow-up (160 carious teeth per 1000), then applying a resin-based sealant would reduce the proportion of carious surfaces to 5.2% (95% CI 3.13% to 7.37%). Similarly, assuming that 40% of control tooth surfaces were decayed (400 carious teeth per 1000), then applying a resin-based sealant would reduce the proportion of carious surfaces to 6.25% (95% CI 3.84% to 9.63%). If 70% of control tooth surfaces were decayed, there would be 19% decayed surfaces in the sealant group (95% CI 12.3% to 27.2%). This caries-preventive effect was maintained at longer follow-up but evidence quality and quantity was reduced (e.g. at 48 to 54 months of follow-up: OR 0.21, 95% CI 0.16 to 0.28, 4 trials, 482 children evaluated; RR 0.24, 95% CI 0.12 to 0.45, 203 children evaluated). Although studies were generally well conducted, we assessed blinding of outcome assessment for caries at high risk of bias for all trials (blinding of outcome assessment is not possible in sealant studies because outcome assessors can see and identify sealant). Glass ionomer sealant versus no sealant: was evaluated by three studies. Results at 24 months were inconclusive (very low-quality evidence). One sealant versus another sealant: the relative effectiveness of different types of sealants is unknown (very low-quality evidence). We included 24 trials that directly compared two different sealant materials. Comparisons varied in terms of types of sealant assessed, outcome measures chosen and duration of follow-up. Adverse events: only four trials assessed adverse events. No adverse events were reported. Resin-based sealants applied on occlusal surfaces of permanent molars are effective for preventing caries in children and adolescents. Our review found moderate-quality evidence that resin-based sealants reduced caries by between 11% and 51% compared to no sealant, when measured at 24 months. Similar benefit was seen at timepoints up to 48 months; after longer follow-up, the quantity and quality of evidence was reduced. There was insufficient evidence to judge the effectiveness of glass ionomer sealant or the relative effectiveness of different types of sealants. Information on adverse effects was limited but none occurred where this was reported. Further research with long follow-up is needed.
Kervanto-Seppälä, Sari; Pietilä, Ilpo; Meurman, Jukka H; Kerosuo, Eero
2009-01-01
Background Pit and fissure sealants (sealants) are widely used as a non-operative preventive method in public dental health in Finland. Most children under 19 years of age attend the community-organized dental health services free of charge. The aims of this study were to find out to what extent sealants were applied, what the attitudes of dental professionals towards sealant application were, and whether any existing sealant policies could be detected among the health centres or among the respondents in general. The study evaluated changes that had taken place in the policies used during a ten year period (1991–2001). Methods A questionnaire was mailed to each chief dental officer (CDO) of the 265 public dental health centres in Finland, and to a group of general dentists (GDP) applying sealants in these health centres, giving a total of 434 questionnaires with 22 questions. The response rate was 80% (N = 342). Results A majority of the respondents reported to application of sealants on a systematic basis for children with increased caries risk. The criteria for applying sealants and the actual strategies seemed to vary locally between the dentists within the health centres and between the health centres nationwide. The majority of respondents believed sealants had short- and long-term effects. The overall use of sealants decreased towards the end of the ten year period. The health centres (N = 28) choosing criteria to seal over detected or suspected enamel caries lesion had a DMFT value of 1.0 (SD ± 0.49) at age 12 (year 2000) compared to a value of 1.2 (SD ± 0.47) for those health centres (N = 177) applying sealants by alternative criteria (t-test, p < 0.05). Conclusion There seems to be a need for defined guidelines for sealant application criteria and policy both locally and nationwide. Occlusal caries management may be improved by shifting the sealant policy from the traditional approach of prevention to interception, i.e. applying the sealants over detected or suspected enamel caries lesions instead of sealing sound teeth. PMID:19193239
Vital Signs: Dental Sealant Use and Untreated Tooth Decay Among U.S. School-Aged Children.
Griffin, Susan O; Wei, Liang; Gooch, Barbara F; Weno, Katherine; Espinoza, Lorena
2016-10-21
Tooth decay is one of the greatest unmet treatment needs among children. Pain and suffering associated with untreated dental disease can lead to problems with eating, speaking, and learning. School-based dental sealant programs (SBSP) deliver a highly effective intervention to prevent tooth decay in children who might not receive regular dental care. SBSPs benefits exceed their costs when they target children at high risk for tooth decay. CDC used data from the National Health and Nutrition Examination Survey (NHANES) 2011-2014 to estimate current prevalences of sealant use and untreated tooth decay among low-income (≤185% of federal poverty level) and higher-income children aged 6-11 years and compared these estimates with 1999-2004 NHANES data. The mean number of decayed and filled first molars (DFFM) was estimated for children with and without sealants. Averted tooth decay resulting from increasing sealant use prevalence was also estimated. All reported differences are significant at p<0.05. From 1999-2004 to 2011-2014, among low- and higher-income children, sealant use prevalence increased by 16.2 and 8.8 percentage points to 38.7% and 47.8%, respectively. Among low-income children aged 7-11 years, the mean DFFM was almost three times higher among children without sealants (0.82) than among children with sealants. Approximately 6.5 million low-income children could potentially benefit from the delivery of sealants through SBSP. The prevalence of dental sealant use has increased; however, most children have not received sealants. Increasing sealant use prevalence could substantially reduce untreated decay, associated problems, and dental treatment costs.
NASA Astrophysics Data System (ADS)
Raethong, P.; Boonkerd, K.
2017-07-01
Adhesion property of natural rubber (NR) and reclaimed natural rubber (RNR) based sealant with concrete was studied here. The effect of tackifier type and loading on the tensile properties of the rubber based sealant sandwished between two flat cements was evaluated. There are three different tackifiers including Coumarone-indene resin (CI), petro resin (PE) and gum rosin (GR). The result initially showed that at the 20 phr of tackifier both NR and RNR sealant mixed with CI consumed the highest force to separate the rubber based sealant from the concrete. This might be due to the highest compatiblility between CI and rubber. Regardless of the tackifier type, all NR based sealants showed the cohesive failure while all RNR based sealants only showed the adhesive failure. Moreover, the NR based sealant seemed to be stronger than the RNR based one. When considering the effect of CI loading on the adhesion, it was shown that for both NR and RNR based sealents, the highest stress was observed when the rubber based sealant loaded with the 20 phr of CI.
Guo, Jinshan; Kim, Gloria B.; Shan, Dingying; Kim, Jimin P.; Hu, Jianqing; Wang, Wei; Hamad, Fawzi G.; Qian, Guoying; Rizk, Elias B.; Yang, Jian
2016-01-01
For the first time, a convenient copper-catalyzed azide-alkyne cycloaddition (CuAAC, click chemistry) was successfully introduced into injectable citrate-based mussel-inspired bioadhesives (iCMBAs, iCs) to improve both cohesive and wet adhesive strengths and elongate the degradation time, providing numerous advantages in surgical applications. The major challenge to developing such an adhesive was the mutual inhibition effect between the oxidant used for crosslinking catechol groups and the Cu(II) reductant used for CuAAC, which was successfully minimized by adding a biocompatible buffering agent typically used in cell culture, 4-(2-hydroxyethyl) -1-piperazineethanesulfonic acid (HEPES), as a copper chelating agent. Among the investigated formulations, the highest adhesion strength achieved (223.11 ± 15.94 kPa) was around 13 times higher than that of a commercially available fibrin glue (15.4 ± 2.8 kPa). In addition, dual-crosslinked (i.e. click crosslinking and mussel-inspired crosslinking) iCMBAs still preserved considerable antibacterial and antifungal capabilities that are beneficial for the bioadhesives used as hemostatic adhesives or sealants for wound management. PMID:27770631
Developing a test method to investigate water susceptibility of joint and crack sealants.
DOT National Transportation Integrated Search
2016-10-31
Sealants are commonly used to insulate cracks and joints preventing water from entering the underlying structure. However, extended exposure of sealants to water has shown to negatively impact sealants properties causing gradual degradation of sealan...
Systematic review on the use of matrix-bound sealants in pancreatic resection.
Smits, F Jasmijn; van Santvoort, Hjalmar C; Besselink, Marc G H; Borel Rinkes, Inne H M; Molenaar, I Quintus
2015-11-01
Pancreatic fistula is a potentially life-threatening complication after a pancreatic resection. The aim of this systematic review was to evaluate the role of matrix-bound sealants after a pancreatic resection in terms of preventing or ameliorating the course of a post-operative pancreatic fistula. A systematic search was performed in the literature from May 2005 to April 2015. Included were clinical studies using matrix-bound sealants after a pancreatic resection, reporting a post-operative pancreatic fistula (POPF) according to the International Study Group on Pancreatic Fistula classification, in which grade B and C fistulae were considered clinically relevant. Two were studies on patients undergoing pancreatoduodenectomy (sealants n = 67, controls n = 27) and four studies on a distal pancreatectomy (sealants n = 258, controls n = 178). After a pancreatoduodenectomy, 13% of patients treated with sealants versus 11% of patients without sealants developed a POPF (P = 0.76), of which 4% versus 4% were clinically relevant (P = 0.87). After a distal pancreatectomy, 42% of patients treated with sealants versus 52% of patients without sealants developed a POPF (P = 0.03). Of these, 9% versus 12% were clinically relevant (P = 0.19). The present data do not support the routine use of matrix-bound sealants after a pancreatic resection, as there was no effect on clinically relevant POPF. Larger, well-designed studies are needed to determine the efficacy of sealants in preventing POPF after a pancreatoduodenectomy. © 2015 International Hepato-Pancreato-Biliary Association.
Outcomes of using a sutureless bovine pericardial patch graft for Ahmed glaucoma valve implantation.
Quaranta, Luciano; Riva, Ivano; Floriani, Irene C
2013-01-01
To evaluate the long-term outcomes of a surgical technique using a sutureless bovine pericardial patch graft for the implantation of an Ahmed glaucoma valve (AGV). This was a pilot study on patients with primary open-angle glaucoma refractory to repeated surgical filtering procedures. All patients underwent AGV implant technique using a sutureless bovine pericardial patch graft. The pericardial membrane was cut using an ordinary corneal trephine with a diameter of 9.0 or 10.0 mm. The anterior part of the tube was covered with the graft and kept in place with fibrin glue. Subsequently, the cap was stitched all around the tube and the dissected conjunctiva was laid over it. Intraocular pressure (IOP) and complications were evaluated 1 week and 1, 3, 6, 12, and 24 months after surgery. The procedure was used to treat 20 eyes of 20 consecutive patients (12 men and 8 women: mean age [SD] 64.8 [7.8] years). Mean IOP was 28.1 mm Hg (SD 4.9) at baseline and decreased to 14.9 mm Hg (SD 1.5) 24 months after surgery (p<0.001). The overall mean number of topical medications was 3.1 (SD 0.5) at baseline and decreased to 1.4 (SD 0.8) after 24 months (p<0.001). During follow-up, there was no conjunctival erosion, thinning of pericardial patch graft over the tube, or tube exposure; no signs of endophthalmitis were recorded. The results suggest that the sutureless technique using a bovine pericardial graft patch is a safe and rapid procedure for AGV implantation.
Sutureless human sclera donor patch graft for Ahmed glaucoma valve.
Zeppa, Lucio; Romano, Mario R; Capasso, Luigi; Tortori, Achille; Majorana, Mara A; Costagliola, Ciro
2010-01-01
To report the safety and effectiveness of a sutureless human sclera donor patch graft covering the subconjunctival portion of glaucoma drainage implant tube to prevent its erosion throughout the overlying conjunctiva. This was a prospective pilot study. Fifteen eyes of 15 consecutive patients not responsive to medical and to not-implant surgical glaucoma treatment underwent Ahmed glaucoma valve (AGV) implant surgery with sutureless human sclera donor patch graft. The surgical procedure included AVG implant placed 8 mm behind the corneal limbus and fixed to the sclera with two 9-0 black nylon sutures. The tube was passed through the scleral tunnel, parallel to the corneal limbus, and shortened at the desired length. The anterior part of the tube was covered with human donor scleral graft and kept in place with fibrin glue (Tissue Coll) under the conjunctiva. Examinations were scheduled at baseline and then at 1 week and 1, 3, 6, and 12 months after surgery. At 12-month follow-up, the best-corrected visual acuity did not significantly improve from baseline 0.78+/-1.2 logMAR, whereas mean intraocular pressure significantly decreased from preoperative values of 29.8 (SD 8.4) mmHg. In all cases, the scleral patch was found in place at each check during the follow-up period. No conjunctival erosion over the AGV tube nor sign of endophthalmitis was recorded at any time during the follow-up period. AVG implant surgery with sutureless human sclera donor patch graft represents an effective and relatively safe surgical procedure for complicated glaucomas, avoiding conjunctival erosions over the AGV tube.
Carey, Joseph N; Sheckter, Clifford C; Watt, Andrew J; Lee, Gordon K
2013-08-01
Despite advances in nutritional supplementation, sepsis management, percutaneous drainage and surgical technique, enterocutaneous fistulae remain a considerable source of morbidity and mortality. Use of adjunctive modalities including negative pressure wound therapy and fibrin glue have been shown to improve the rapidity of fistula closure; however, the overall rate of closure remains poor. The challenge of managing chronic, high-output proximal enterocutaneous fistulae can be successfully achieved with appropriate medical management and intra-abdominal placement of pedicled rectus abdominis muscle flaps. We report two cases of recalcitrant high output enterocutaneous fistulae that were treated successfully with pedicled intra-abdominal rectus muscle flaps. Indications for pedicled intra-abdominal rectus muscle flaps include persistent patency despite a reasonable trial of non-operative intervention, failure of traditional operative interventions (serosal patch, Graham patch), and persistent electrolyte and nutritional abnormalities in the setting of a high-output fistula. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Orsi, Patrícia Rodrigues; Landim-Alvarenga, Fernanda Cruz; Justulin, Luis Antônio; Kaneno, Ramon; de Assis Golim, Marjorie; Dos Santos, Daniela Carvalho; Creste, Camila Fernanda Zorzella; Oba, Eunice; Maia, Leandro; Barraviera, Benedito; Ferreira, Rui Seabra
2017-09-29
The injection of mesenchymal stem cells (MSCs) directly into the bone of osteoporotic (OP) patients for rapid recovery has been studied worldwide. Scaffolds associated with MSCs are used to maintain and avoid cell loss after application. A unique heterologous fibrin sealant (HFS) derived from snake venom was evaluated for the cytotoxicity of its main components and as a three-dimensional biological scaffold for MSCs to repair a critical femur defect in osteoporotic rats. The cytotoxicity of HFS was assessed using a 3-(4,5-dimethyl-2-thiazolyl)-2,5-diphenyl-2H-tetrazoliumbromide (MTT) assay and transmission electron microscopy. The cells were cultured, characterized by flow cytometry and differentiated into the osteogenic lineage. Two-month-old rats underwent ovariectomy to induce OP. After 3 months, a 5 mm critical bone defect was made in the distal end of the rat femurs and filled with HFS; HFS + MSCs; and HFS + MSCs D (differentiated into the osteogenic lineage) to evaluate the effects. An injury control group (injury and no treatment) and blank control group (no injury and no treatment) were also included. The animals were observed at days 14 and 28 by microtomographic (micro-CT) analyses, histologic and biochemical analysis, as well as scanning electron microscopy. The results revealed that one of the compounds of HFS, the thrombin-like enzyme extracted from snake venom, had no cytotoxic effects on the MSCs. OP was successfully induced, as demonstrated by the significant differences in the levels of 17β-estradiol, Micro-CT analyses and alkaline phosphatase between the ovariectomized (OVX) and non-ovariectomized (NOVX) groups. The histological data revealed that at 14 days after surgery in both the OVX and NOVX animals, the HFS + CTMs and HFS + CTMsD showed a higher formation of bone cells at the site in relation to the control group (without treatment). Collagen formation was evidenced through bone neoformation in all treated and control groups. No morphological differences in the femurs of the NOVX and OVX animals were observed after the surgical procedure. Scanning electron microscopy (SEM) confirmed the histological analysis. The new HFS composed of two non-toxic components for MSCs showed capacity to promote the recovery of the bone lesions in OVX and NOVX animals at 14 days after surgery. In addition, the HFS enabled the differentiation of MSCs into MSCs D in the group treated with HFS + MSCs. Using the MSCs and/or MSCs D together with this biopharmaceutical could potentially enable significant advances in the treatment of osteoporotic fractures. Future clinical trials will be necessary to confirm these results.
A comparison of the effects of toothbrushing and handpiece prophylaxis on retention of sealants.
Kolavic Gray, Shellie; Griffin, Susan O; Malvitz, Dolores M; Gooch, Barbara F
2009-01-01
Tooth surface cleaning before acid etching is considered to be an important step in the retention of resin-based pit-and-fissure sealants. The authors reviewed and summarized instructions for cleaning tooth surfaces from five manufacturers of 10 unfilled resin-based sealants marketed in the United States. The authors also searched electronic databases for studies that directly compared the effects of different surface-cleaning methods on sealant retention and for systematic reviews of the effectiveness of sealants. They explored the association between surface-cleaning methods and sealant retention in the studies included in the systematic reviews. They calculated the summary weighted retention rates for studies that used either a handpiece or toothbrush prophylaxis. All of the sealant manufacturers' instructions for use (IFU) recommended cleaning the tooth before acid etching. None of the IFU directly stated that a handpiece was required to perform the cleaning, but five IFU implied the use of handpiece prophylaxis. None of the IFU recommended surface-altering procedures in caries-free teeth. Direct evidence from two clinical trials showed no difference in complete sealant retention between surfaces cleaned mechanically with pumice or prophylaxis paste and those cleaned with air-water syringe or dry toothbrushing. Indirect evidence from 10 studies found that weighted summary retention by year after sealant placement in studies that used toothbrush prophylaxis was greater than or equivalent to values for studies that used handpiece prophylaxis. Levels of sealant retention after surface cleaning with toothbrush prophylaxis were at least as high as those associated with hand-piece prophylaxis. This finding may translate into lower resource costs for sealant placement.
Systematic review on the use of matrix-bound sealants in pancreatic resection
Smits, F Jasmijn; van Santvoort, Hjalmar C; Besselink, Marc G H; Borel Rinkes, Inne H M; Molenaar, I Quintus
2015-01-01
Background Pancreatic fistula is a potentially life-threatening complication after a pancreatic resection. The aim of this systematic review was to evaluate the role of matrix-bound sealants after a pancreatic resection in terms of preventing or ameliorating the course of a post-operative pancreatic fistula. Methods A systematic search was performed in the literature from May 2005 to April 2015. Included were clinical studies using matrix-bound sealants after a pancreatic resection, reporting a post-operative pancreatic fistula (POPF) according to the International Study Group on Pancreatic Fistula classification, in which grade B and C fistulae were considered clinically relevant. Results Two were studies on patients undergoing pancreatoduodenectomy (sealants n = 67, controls n = 27) and four studies on a distal pancreatectomy (sealants n = 258, controls n = 178). After a pancreatoduodenectomy, 13% of patients treated with sealants versus 11% of patients without sealants developed a POPF (P = 0.76), of which 4% versus 4% were clinically relevant (P = 0.87). After a distal pancreatectomy, 42% of patients treated with sealants versus 52% of patients without sealants developed a POPF (P = 0.03). Of these, 9% versus 12% were clinically relevant (P = 0.19). Conclusions The present data do not support the routine use of matrix-bound sealants after a pancreatic resection, as there was no effect on clinically relevant POPF. Larger, well-designed studies are needed to determine the efficacy of sealants in preventing POPF after a pancreatoduodenectomy. PMID:26292846
Hasanuddin, S; Reddy, E R; Manjula, M; Srilaxmi, N; Rani, S T; Rajesh, A
2014-10-01
To evaluate and compare retention and caries occurance following placement of Clinpro and FUJI VII fissure sealants, by two different techniques simultaneously in unsealed, contralateral young permanent molars of 7- to 10-year-old children affected by mild to moderate dental fluorosis at various recall intervals of 1 week, 1, 3, 6 and 12 months. 80 schoolchildren with mild to moderate dental fluorosis were assigned to Group A and Group B with 40 children in each group. In Group A Clinpro fissure sealant and in Group B Fuji VII fissure sealant was used. In both the groups fissure sealants were applied by conventional fissure sealant technique (CST) on one side and enameloplasty sealant technique (EST) on the other side of the same arch. The applied fissure sealants were evaluated clinically for retention and caries incidence. Clinpro fissure sealant showed a retention rate of 95% when compared with Fuji VII (57.5%) at the end of 12 months, which was statistically significant. Regarding techniques, EST showed better results than CST in both the groups. Comparison of groups with respect to retention and techniques at different time periods was performed using Mann-Whitney U test (p < 0.05). Comparison of different time periods with respect to retention and technique in all the groups was performed using Wilcoxon matched pairs test by ranks (p < 0.05). Clinpro fissure sealant showed better retention at all treatment intervals, when compared with Fuji VII. Further follow-up is required to study the efficacy of the fissure sealant placement techniques.
Shimazu, Kisaki; Ogata, Kiyokazu; Karibe, Hiroyuki
2012-01-01
We aimed to evaluate the caries-preventive effect of a fissure sealant containing surface reaction-type pre-reacted glass ionomer (S-PRG) filler and bonded by self-etching primer versus those of 2 conventional resin-based sealants bonded by acid etching in terms of its impact on enamel demineralization and remineralization, enamel bond strength, and integrity of debonded enamel surfaces. Demineralization, remineralization, and bond strength on untreated enamel and enamel subsurface lesions of bovine incisors were assessed among the sealants by polarizing microscopy and microradiography; debonded enamel surfaces were examined by scanning electron microscopy. The conventional resin-based sealants bonded by acid etching caused surface defects on the enamel subsurface lesions and significantly increased the lesion depth (p = 0.014), indicative of enamel demineralization. However the S-PRG filler-containing sealant bonded by self-etching primer maintained the enamel surface integrity and inhibited enamel demineralization. No difference in bond strength on both untreated enamel and enamel subsurface lesions was noted among the sealants. An S-PRG filler-containing fissure sealant bonded by self-etching primer can prevent enamel demineralization, microleakage, and gaps without the tags created by acid etching regardless of the enamel condition. Such sealants are suitable for protecting the pits and fissures of immature permanent teeth.
Khogli, Ahmed Eltigani; Cauwels, Rita; Vercruysse, Chris; Verbeeck, Ronald; Martens, Luc
2013-01-01
Optimal pit and fissure sealing is determined by surface preparation techniques and choice of materials. This study aimed (i) to compare the microleakage and penetration depth of a hydrophilic sealant and a conventional resin-based sealant using one of the following preparation techniques: acid etching (AE) only, a diamond bur + AE, and Er:YAG laser combined with AE, and (ii) to evaluate the microleakage and penetration depth of the hydrophilic pit and fissure sealant on different surface conditions. Eighty recently extracted 3rd molars were randomly assigned to eight groups of ten teeth according to the material, preparation technique, and surface condition. For saliva contamination, 0.1 mL of fresh whole human saliva was used. All samples were submitted to 1000 thermal cycles and immersed in 2% methylene blue dye for 4 h. Sections were examined by a light microscope and analysed using image analysis software (Sigmascan(®)). The combination of Er:YAG + AE + conventional sealant showed the least microleakage. The sealing ability of the hydrophilic sealant was influenced by the surface condition. Er:YAG ablation significantly decreased the microleakage at the tooth-sealant interface compared to the non-invasive technique. The hydrophilic sealant applied on different surface conditions showed comparable result to the conventional resin-based sealant. © 2012 The Authors. International Journal of Paediatric Dentistry © 2012 BSPD, IAPD and Blackwell Publishing Ltd.
Lim, G H; Leslie, K E; Kelton, D F; Duffield, T F; Timms, L L; Dingwell, R T
2007-03-01
The efficacy and adherence of an external teat sealant applied at drying off was evaluated in 2 studies between 1997 and 1999. At drying off, 2 quarters were randomized to receive intramammary dry-cow antibiotic therapy, and the remaining 2 quarters were treated with either a single or double application of external teat sealant. Approximately 3 d before calving, all teats that had been dipped at drying off were redipped in a single coating of teat sealant. Adherence of the teat sealant was scored for the first 2 wk after drying off, and physical traits of the teat skin and teat ends were recorded. Quarter milk samples were collected 1 wk before drying off, at drying off, 0 to 7 d, and 14 to 21 d postcalving. Somatic cell counts were determined from quarter samples taken at d 7 and 14 to 21 d after calving. Data were analyzed from 172 dry periods of 162 cows. The mean time of sealant adherence following drying off application was 3 +/- 0.13 d. Double sealant application significantly increased the duration of adherence by 0.67 d. Teats that had teat sealant applied twice at drying off and that had up to 3 d of adherence had the lowest linear score (LS) at 14 to 21 d (1.89 +/- 0.31) of all quarters. The LS of quarters that received antibiotic therapy only was 2.27 +/- 0.19. The majority of intramammary infections identified at drying off were caused by the minor pathogens, coagulase-negative staphylococci and Corynebacterium bovis (51 and 23%, respectively). The results from this study indicate that duration of sealant adherence to the teat-end should be considered when evaluating the impact of teat sealant treatment at drying off on the level of infection after calving. Double sealant application, cooler seasons, and longer teat lengths were associated with a significant increase in the duration of sealant adherence to the teat-end.
A One-Year Evaluation of a Free Fissure Sealant Program
M, Bakhtiar; N, Azadi; A, Golkari
2016-01-01
Statement of Problem: Pit and fissure sealant therapy has been approved as an effective measure in the prevention of occlusal dental caries. Resin based materials are the most common materials used worldwide. A variety of resin based fissure sealants are produced and used. Most of them have been presented with ideal results in research environment. However, their effectiveness in the real life, especially in a mass application program such as Iran’s oral health reform plan is not clear. Objectives: To evaluate the longevity of different fissure sealant applied in Iran’s oral health reform plan in Fars Province (south of Iran) after one year. Materials and Methods: Seven counties were selected. One hundred 6- to 8-year-old school children who had undergone fissure sealant therapy in spring 2015 were randomly selected from each county. Their first molars were examined to evaluate the status of the fissure sealants which were applied one year ago. Data on the type/brand of fissure sealant materials, type and experience of clinicians who applied them, existence of a chair-side assistant, and whether the children were caries-free at the time of fissure sealant application were collected from the existing reports. Results: Data of 1974 teeth from 598 children were used for the final analysis. The effects of type/brand of the material was significant on the final results and remained significant (p < 0.001) after adjustments for the level of fluoride, urban/rural area, upper/lower jaw, type of clinician who applied the sealant, existence of a chair-side assistant, and child’s gender, age, and being caries-free. Conclusions: Many factors affect the success rate of a fissure sealant therapy program. The type/brand of the material remained significantly related to the success rate of the fissure sealant even after adjustments for other influencing factors. In this study, ClinproTM Sealant (3M/ESPE, USA) showed better longevity after one year of application. PMID:28959758
A One-Year Evaluation of a Free Fissure Sealant Program.
M, Bakhtiar; N, Azadi; A, Golkari
2016-12-01
Pit and fissure sealant therapy has been approved as an effective measure in the prevention of occlusal dental caries. Resin based materials are the most common materials used worldwide. A variety of resin based fissure sealants are produced and used. Most of them have been presented with ideal results in research environment. However, their effectiveness in the real life, especially in a mass application program such as Iran's oral health reform plan is not clear. To evaluate the longevity of different fissure sealant applied in Iran's oral health reform plan in Fars Province (south of Iran) after one year. Seven counties were selected. One hundred 6- to 8-year-old school children who had undergone fissure sealant therapy in spring 2015 were randomly selected from each county. Their first molars were examined to evaluate the status of the fissure sealants which were applied one year ago. Data on the type/brand of fissure sealant materials, type and experience of clinicians who applied them, existence of a chair-side assistant, and whether the children were caries-free at the time of fissure sealant application were collected from the existing reports. Data of 1974 teeth from 598 children were used for the final analysis. The effects of type/brand of the material was significant on the final results and remained significant ( p < 0.001) after adjustments for the level of fluoride, urban/rural area, upper/lower jaw, type of clinician who applied the sealant, existence of a chair-side assistant, and child's gender, age, and being caries-free. Many factors affect the success rate of a fissure sealant therapy program. The type/brand of the material remained significantly related to the success rate of the fissure sealant even after adjustments for other influencing factors. In this study, ClinproTM Sealant (3M/ESPE, USA) showed better longevity after one year of application.
Messer, L B; Calache, H; Morgan, M V
1997-08-01
The benefit of a public sector sealant programme for children in Australia is yet to be established. This study evaluated sealants placed by therapists of the School Dental Service in Victoria, between 1989 and 1994, on permanent teeth of children in 15 primary schools in Melbourne. Seven hundred and seventy four children aged 6-12 years were examined in school dental clinics by six calibrated examiners. A total of 5363 sealants placed on 2875 permanent teeth (including 2616 first molars, 91 per cent of sample) up to four and a half years previously was examined. Values for complete and partial sealant retention were highest for premolars (86 per cent, 9 per cent respectively, total 95 per cent); similar for occlusal surfaces of maxillary and mandibular first molars (63 per cent, 30 per cent; 62 per cent, 32 per cent respectively) and buccal pits of mandibular molars (66 per cent); and low for pits/fissures of Carabelli's cusps of maxillary molars (44 per cent). Cross-sectional examination up to 24 months for both maxillary and mandibular first molars indicated average values of 67 per cent complete retention, 27 per cent partial retention, 6 per cent missing; thereafter complete retention decreased and partial retention increased. Sealant failures in the six months post-placement were attributed to technique failure. Regardless of sealant retention, caries experience was low under partially retained or missing sealants (4.5 per cent) and completely retained sealants (0.4 per cent). It is concluded that the SDS sealant programme is a sound preventive dental public health approach.
Ducts Sealing Using Injected Spray Sealant, Raleigh, North Carolina (Fact Sheet)
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
2014-03-01
In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques - manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multi-unit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder two-story. Results show that duct leakage to the outside was reduced by an average of 59% through the usemore » of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.« less
Yokoyama, Yoko; Kakudate, Naoki; Sumida, Futoshi; Matsumoto, Yuki; Gilbert, Gregg H; Gordan, Valeria V
2016-12-01
The study aims were: (i) to examine dentist practice patterns regarding treatment recommendations for dental sealants; and (ii) to identify characteristics associated with this recommendation. The study was performed using a cross-sectional questionnaire survey (Clinicaltrials.gov registration number NCT01680848). Participants were Japanese dentists (n = 282) recruited from the Dental Practice-based Research Network Japan. Three clinical photographs of the occlusal surface of a mandibular first molar were presented, portraying increasing depths of cavitation in a 12-year-old patient with high caries risk. Sealants would be an appropriate treatment in all three scenarios. We asked about the treatment decision for each case. We then performed multiple logistic regression analyses to evaluate associations between the decision to recommend sealants, and dentist, patient and practice characteristics. Responses were obtained from 189 dentists (response rate = 67%). In the hypothetical scenarios, dentists' recommendations for sealants for the 12-year-old patient varied from 16% to 26% across the three hypothetical clinical scenarios. Multiple logistic regression analysis indicated that dentist agreement with the efficacy of assessment for caries risk showed a significant association with the percentages of patients receiving sealants. Dentist practice patterns for sealant treatment recommendation show changes that are dependent on caries severity. The dentists' recommendations for sealants for the 12-year-old patient were low for all three selected scenarios, based on indications for sealants in the American Dental Association guidelines. Recommending a sealant showed a significant relationship with the dentist having a higher agreement with efficacy of caries risk assessment. © 2016 FDI World Dental Federation.
An investigation into sealant restoration usage in general dental practice in England.
Hassall, D C; Mellor, A C
2001-10-13
A study was undertaken to investigate attitudes to sealant restorations and their usage in general dental practice in England. Seventy three dentists in three areas (Doncaster, Hereford/Worcester and Wycombe) provided retrospective details of treatment provided over a one year period for 4,250 6-12 and 13-15 year old subjects. Fifty nine of these dentists then completed a telephone questionnaire relating to their treatment patterns and attitudes to sealant restorations. The treatment data indicated that only 59 of the 4,250 children received a sealant restoration during the study period. Of the 44 dentists who claimed in the questionnaire to be using sealant restorations, only 28 had placed them in their selected patients. Positive attitudes to sealant restorations were expressed but also concerns that may be prejudicing usage.
Fonouni, Hamidreza; Kashfi, Arash; Majlesara, Ali; Stahlheber, Oliver; Konstantinidis, Lukas; Kraus, Thomas W; Mehrabi, Arianeb; Oweira, Hani
2017-09-01
One of the widely accepted adjunctive agents in the variety of surgical modalities are sealants. Our study aim was to compare four commonly used modern sealants in a standardized experimental setting to assess their feasibility, and hemostatic efficacy in vascular anastomosis. Forty landrace pigs (weight: 24.7 ± 3.8 kg) were randomized into the control (n = 8) and four sealant groups; TachoSil® (n = 8), Tissucol Duo® (n = 8), Coseal® (n = 8), and FloSeal® (n = 8). After doing a portal vein end-to-end anastomosis as well as stitches of aortic incision, the sealants were applied on anastomotic site. The control group was left intact. In portal vein anastomosis, the sealants led to a complete hemostasis significantly better than control group. The mean of blood loss was also significantly reduced. In successful subgroups, there was a difference in the mean-time to reach complete hemostasis ranging from 15 s in Coseal® to 76 s in FloSeal® group (p < 0.05). In aortotomy experiments, except Tissucol Due®, which had insufficient hemostasis, other sealants led to a complete hemostasis. The mean blood loss was significantly reduced in sealants groups as well. The four sealants are effective in reducing the suture-hole bleeding in portal vein anastomosis. However, the hemostatic potential is heterogeneous among sealants. This means that "one-size-fits-all" approach is not appropriate for application of sealants in diversity of vascular surgery and it should be based on the type and the severity of injury and the structure of tissue. Comparison of hemostasis efficacy of four modern sealants (TachoSil®, Tissucol Duo®, Coseal®, and FloSeal®) in vascular anastomosis in porcine model. The figures below show the total blood loss (g) in the control and sealant groups after aortotomy (left) and portal vein anastomosis (right). The mean of blood loss decreased significantly by the usage of sealants in both experiment groups as compared to control group (*: p < 0.05; sealant groups vs. control group). 1. The right column shows the mean of blood loss (g) in all experiments in each group. 2. The middle column presents the subgroup with unsuccessful hemostasis at the end of observation time (Tmax = 20 sec. for aortotmy and 300 sec. for portal vein anastomosis). 3. The left column shows mean of total blood loss in subgroups with successful hemostasis during observation time (20 sec for aortotomy and 300 sec for portal vein).
Monitoring Sealant Durability during Instrumented Outdoor Exposure with Variation in Prestrain
Gregory T. Schueneman; Steven Lacher; Christopher G. Hunt
2015-01-01
Sealants are a vital part of a buildingâs environmental barrier envelope. Their ability to bond to numerous dissimilar substrates and form cure-in-place seals results in their widespread use throughout single story and high rise buildings. A typical 40 story concrete and glass facade building can have 70 miles of sealant bonds. Failure of sealants can lead to energy...
Burbank, Brant D; Cooper, Ryan L; Kava, Alyssa; Hartjes, Jennifer M; McHale, William A; Latta, Mark A; Gross, Stephen M
2017-04-01
To determine if pit-and-fissure sealants with microencapsulated remineralizing agents with sustained release of fluoride, calcium and phosphate ions could promote enamel fluoride uptake by demineralized tooth structure. Sealants that contained 5 w/w% microcapsules with aqueous solutions of 5M Ca(NO3)2 or 0.8M NaF or 6.0M K2HPO4 or a mixture of all three were prepared. Ion release profiles were measured as a function of time. Enamel fluoride uptake by demineralized tooth structure was determined. Sustained release of fluoride, calcium and phosphate ions from a sealant was demonstrated. Fluoride uptake by demineralized enamel was significantly increased compared to a control sealant manufactured without microcapsules (P< 0.01). Bovine enamel that contained 2.2±2.1 µg F/g of enamel prior to exposure to a sealant without microcapsules had 2.3±0.5 after 90 days. Enamel exposed to sealant with 5w/% NaF microcapsules went from 3.5±3.5 µg F/g of enamel prior to exposure to 148±76 after 90 days. Enamel exposed to sealant with 2 w/w% NaF, 2 w/w% Ca(NO3)2 and 1 w/w% K2HPO4 microcapsules went from 1.7±0.7 µg F/g of enamel prior to exposure to 190±137 after 90 days. Sealants with encapsulated remineralizing agents were capable of releasing biologically available fluoride, calcium, and phosphate ions. Incorporation of these microcapsules in pit and fissure sealants is a promising method for remineralization determined by enamel fluoride uptake measurements.
Hariprasad, Seenu M; Singh, Ajay
2011-03-01
To test a novel hydrogel sealant to secure sutureless sclerotomies under variable intraocular pressure conditions. In cadaver eyes, 23- and 20-gauge (G) sclerotomies were constructed. Sixteen 23-G beveled sclerotomies were constructed in 4 eyes: 8 of the incisions were treated with hydrogel sealant, while 8 were left bare. All sclerotomies were monitored for leaks while the intraocular pressure was elevated. The pressure on incision leakage was recorded as the leak pressure (maximum tested = 140 mm Hg). Additionally, sixteen 20-G sclerotomies were constructed in 4 other eyes: 8 of the incisions were treated with hydrogel sealant, while 8 were sutured. These incisions were similarly pressure tested. Among the 23-G incisions, hydrogel sealant application to the incisions significantly increased the leak pressure relative to bare incisions: mean (SE), 131.8 (8.2) vs 39.5 (5.2) mm Hg, respectively (P < .001). Only 1 of the 8 sealant-treated 23-G incisions leaked below 140 mm Hg, compared with all of the 8 bare incisions. Among the 20-G incisions, there was no difference in leak pressure among sealant-treated and sutured incisions: mean (SE), 140.0 (0.0) vs 136.3 (3.8) mm Hg, respectively (P = .35). None of the 8 sealant-treated 20-G incisions leaked below 140 mm Hg, compared with 1 of the 8 sutured incisions. Hydrogel sealant significantly increased the leak pressure among 23-G incisions relative to 23-G bare incisions and was equivalent to suturing among 20-G incisions. Hydrogel sealants effectively close vitrectomy incisions and may decrease the incidence of postoperative endophthalmitis and hypotony.
Lygidakis, N A; Dimou, G; Stamataki, E
2009-12-01
This was to evaluate the retention rate of fissure sealants applied to MIH molars with occlusal enamel opacities, using two different application methods after 4 years. 54 children exhibiting molars with MIH aged 6-7 years, participated in the study. presence of at least 2 fully erupted caries-free maxillary or mandibular first permanent molars in the opposite sides of the mouth, both with occlusal enamel opacities without breakdown. Following parental consent, sealants were applied using a half-mouth experimental design. Group A: On a randomly assigned first molar on one side of the mouth sealants Fissurit were placed using a single bottle adhesive system (One-step prior to sealant application. Group B: Sealants were applied on the contra-lateral molar using the conventional etch and seal technique. Children were seen biannually when a preventive program was applied, without replacing any lost sealant. After 4 years, 47 sets of molars (94 teeth) were available for blind evaluation. Teeth in Group A presented a better retention rate; 70.2% were fully sealed, 29.7% partly sealed and none unsealed (lost sealant). Group B revealed 25.5% fully sealed, 44.6% partly sealed and 29.7% unsealed teeth. Differences between groups A and B were statistically significant (p<0.001). Also both groups revealed a decreasing retention rate over the 4-year period (p<0.001). There was no difference in dental caries increment rate and enamel breakdowns at the end of the study (p>0.01). In hypomineralised molars with occlusal opacities sealants appear to have greater retention when applied using 5th generation adhesive systems prior to sealant.
Resealing concrete pavement joints
DOT National Transportation Integrated Search
1999-07-01
The primary objective of this study was to evaluate the relative performance of the selected joint sealant materials. Other objectives were to determine the effect of selected sealant configurations and installation methods, and to identify sealant m...
Hu, Xuan; Fan, Mingwan; Rong, Wensheng; Lo, Edward C M; Bronkhorst, Ewald; Frencken, Jo E
2014-08-01
The aim of this study was to test the hypothesis that the colour photograph method has a higher level of validity for assessing sealant retention than the visual clinical examination and replica methods. Sealed molars were assessed by two evaluators. The scores for the three methods were compared against consensus scores derived through assessing retention from scanning electron microscopy images (reference standard). The presence/absence (survival) of retained sealants on occlusal surfaces was determined according to the traditional and modified categorizations of retention. Sensitivity, specificity, and Youden-index scores were calculated. Sealant retention assessment scores for visual clinical examinations and for colour photographs were compared with those of the reference standard on 95 surfaces, and sealant retention assessment scores for replicas were compared with those of the reference standard on 33 surfaces. The highest mean Youden-index score for the presence/absence of sealant material was observed for the colour photograph method, followed by that for the replica method; the visual clinical examination method scored lowest. The mean Youden-index score for the survival of retained sealants was highest for the colour photograph method for both the traditional (0.882) and the modified (0.768) categories of sealant retention, whilst the visual clinical examination method had the lowest Youden-index score for these categories (0.745 and 0.063, respectively). The colour photograph method had a higher validity than the replica and the visual examination methods for assessing sealant retention. © 2014 Eur J Oral Sci.
Mesquita-Guimarães, Késsia Suênia Fidelis de; Sabbatini, Iliana Ferraz; Almeida, Cintia Guimarães de; Galo, Rodrigo; Nelson-Filho, Paulo; Borsatto, Maria Cristina
2016-01-01
Dental sealants are important for prevention of carious lesions, if they have good shear strength. The aim of this study was to evaluate the shear bond strength (SBS) of two sealants to saliva-contaminated and non-contaminated enamel with and without an intermediate adhesive layer underneath the sealant. Ninety flat enamel surfaces from human third molars were randomly assigned to 6 groups (n=15): F (control): Fluroshield(tm) sealant; EWB (control): Embrace(tm) WetBond(tm); SB/F: Single Bond adhesive system + F; SB/EWB, s-SB/F and s-SB/EWB. In the s-SB/F and s-SB/EWB groups, the acid-etched enamel was contaminated with 0.01 mL of fresh human saliva for 20 s. Sealant cylinders were bonded to enamel surface with and without an intermediate adhesive system layer. The shear tests were performed using a universal testing machine (0.5 mm/min). Data were analyzed statistically by Kruskal-Wallis and Mann-Whitney tests (α=0.05). F presented higher mean SBS than EWB in all experimental conditions. The lowest SBS mean was obtained for EWB on contaminated enamel (p<0.05). In conclusion, an adhesive system layer should be used prior to sealant placement, in both dry and saliva-contaminated enamel. F had the best performance in all experimental conditions. EWB sealant showed very low results, but an adhesive layer underneath the sealant increased its SBS even after salivary contamination.
Air Distribution Retrofit Strategies for Affordable Housing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dentz, Jordan; Conlin, Francis; Holloway, Parker
2014-03-01
In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques -- manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multi-unit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder two-story. Results show that duct leakage to the outside was reduced by an average of 59% through the usemore » of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.« less
Air Distribution Retrofit Strategies for Affordable Housing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dentz, J.; Conlin, F.; Holloway, Parker
2014-03-01
In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques, manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multiunit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder are two story. Results show that duct leakage to the outside was reduced by an average of 59% through themore » use of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.« less
Khatri, Sachin G; Samuel, Srinivasan Raj; Acharya, Shashidhar; Patil, Snehal; Madan, Kavita
2015-01-01
The purpose of this study was to evaluate and compare the retention rates and development of caries in permanent molars in children sealed with moisture-tolerant, resin-based (Embrace WetBond), and conventional resin-based (Helioseal) sealant over a period of one year. This was a double blind, split-mouth, randomized controlled trial among six- to nine-year-olds. Sixty-eight permanent mandibular first molars in 34 children were randomly assigned to be sealed with Embrace WetBond or Helioseal sealant. The final sample was 32 children with 64 teeth. At 12 months, 23 of 32 (72 percent) sealants were completely retained in Embrace WetBond, whereas only 16 of 32 (50 percent) were retained in the Helioseal group. There was a statistically significant difference in retention rates of Embrace WetBond and Helioseal sealants at 12 months (P<.05). At 12 months follow-up, only two teeth developed caries in Embrace WetBond; in the Helioseal group, five teeth developed caries (two initial and three enamel caries). Embrace WetBond was superior to Helioseal sealant, as Embrace exhibited higher retention and lower caries scores. Embrace WetBond can be preferred over conventional resin-based sealants for community and outreach sealant programs where use of rubber dam for moisture control is difficult to practice.
[Development of elastameric sealant designed for arterial field].
Matsuda, Takehisa; Nakajima, Nobuyuki
2013-04-01
The development of a reliable surgical sealant specific for arterial tissues has been long awaited. In this article, first the "ideal" adhesion mechanism formulated from biomechanical concept is proposed for ensured hemostasis in dissected arteries with pulsatile flow. An urethane prepolymer prepared along the design criteria is viscous liquid. Due to its high water absorbility and high reactivity with water, the sealant applied to vascular tissues becomes an elastomer within several minutes. When the sealant was applied to dissected canine abdominal arteries with 3 stay sutures, followed by declamping 5 minutes, neither bleeding nor detrimental effect on tissue morphogenesis was observed. This sealant is being ready to the market.
Panigrahi, Antarmayee; Srilatha, K T; Panigrahi, Rajat G; Mohanty, Susant; Bhuyan, Sanat K; Bardhan, Debojyoti
2015-07-01
Contamination of etched enamel with saliva has been shown to result in sealant failure. Recently, a hydrophilic sealant has been introduced. In absence of documented literature, this in vitro study was undertaken to ascertain the efficacy of Embrace Wet Bond without reduction of microtensile bond strength in the different moisture contamination. A 5mm block of sealant were built over prepared occlusal surface of 40 non-carious therapeutically extracted third molars which were sectioned into 1mm thick stick and tested using Zwick micro tensile tester. Obtained data were subjected to descriptive analysis, one-way ANOVA and Scheffe's post-hoc tests. Mean microtensile bond strength of Embrace sealant was not significantly lowered in different moisture contamination groups except Group 3 (air drying), which showed very highly significant (p<0.001) decrease in μTBS as compared to Group 1 (non-contaminated). Mean μTBS of Embrace sealant remains largely unchanged even in presence of moisture. Owing to its hydrophilic property, this sealant can be a great help in cases where maintaining isolation is difficult.
Gao, Wentong; Bie, Mengyao; Liu, Fu; Chang, Pengshan; Quan, Yiwu
2017-05-10
Polysulfide sealants have been commercially applied in many industrial fields. In this article, we study the self-healing property of the epoxy resin-cured polysulfide sealants for the first time. The obtained sealants showed a flexible range of ultimate elongation of 157-478% and a tensile strength of 1.02-0.75 MPa corresponding to different polysulfide oligomers. By taking advantage of the dynamic reversible exchange of disulfide bonds, polysulfide sealants exhibited good self-healing ability under a moderate thermal stimulus. A higher molecular weight and a lower degree of cross-linking of polysulfide oligomer were helpful in improving the ultimate elongation and healing efficiency of the polysulfide sealants. After subjecting to a temperature of 75 °C for 60 min, both the tensile strength and ultimate elongation of a fully cut sample, LP55-F, were restored to 91% of the original values, without affecting the sealing property. Furthermore, the sample exhibited excellent reshaping and reprocessing abilities. These outcomes offer a paradigm toward sustainable industrial applications of the polysulfide-based sealants.
Use of radiation in biomaterials science
NASA Astrophysics Data System (ADS)
Benson, Roberto S.
2002-05-01
Radiation is widely used in the biomaterials science for surface modification, sterilization and to improve bulk properties. Radiation is also used to design of biochips, and in situ photopolymerizable of bioadhesives. The energy sources most commonly used in the irradiation of biomaterials are high-energy electrons, gamma radiation, ultraviolet (UV) and visible light. Surface modification involves placement of selective chemical moieties on the surface of a material by chemical reactions to improve biointeraction for cell adhesion and proliferation, hemocompatibility and water absorption. The exposure of a polymer to radiation, especially ionizing radiation, can lead to chain scission or crosslinking with changes in bulk and surface properties. Sterilization by irradiation is designed to inactivate most pathogens from the surface of biomedical devices. An overview of the use of gamma and UV radiation to improve surface tissue compatibility, bulk properties and surface properties for wear resistance, formation of hydrogels and curing dental sealants and bone adhesives is presented. Gamma and vacuum ultraviolet (VUV) irradiated ultrahigh molecular weight polyethylene (UHMWPE) exhibit improvement in surface modulus and hardness. The surface modulus and hardness of UHMWPE showed a dependence on type of radiation, dosage and processing. VUV surface modified e-PTFE vascular grafts exhibit increases in hydrophilicity and improvement towards adhesion of fibrin glue.
Use of occlusal sealant in a community program and caries incidence in high- and low-risk children.
Baldini, Vânia; Tagliaferro, Elaine Pereira da Silva; Ambrosano, Gláucia Maria Bovi; Meneghim, Marcelo de Castro; Pereira, Antonio Carlos
2011-08-01
The aims of this study were to investigate the effectiveness of sealant placement under the guidelines of the Oral Health Promotion Program for Children and Adolescents (Portugal), and to test the influence of clinical and socioeconomic variables on the DMFT increment in 277 children, born in 1997. A dental hygienist performed the initial examinations and sealant placement (Helioseal, Vivadent) on the permanent first molars in 2005. These activities were registered in dental records that were assessed in 2007. Children were classified according to caries risk at baseline [high (HR: DMFT+dmft>0); low (LR: DMFT+dmft=0) risk] and sealant placement as follows: HR-S and LR-S Groups (with sealant placement); HR-NS and LR-NS Groups (without sealant placement). A calibrated dentist performed the final examination in 2007 at school, based on the World Health Organization recommendations. The variables collected were: dental caries, visible dental plaque, malocclusions, and socioeconomic level (questionnaire sent to children's parents). For univariate (Chi-square or Fisher tests) and multivariate (Multiple logistic regression) analyses the DMFT increment >0 was selected as dependent variable. Approximately 17.0% of the children showed DMFT increment>0 (mean=0.25). High-risk children presented a significant increase in the number of decayed and/or filled teeth. These children had 7.94 more chance of developing caries. Children who did not receive sealant were 1.8 more prone to have DMFT increment >0. It appears that sealant placement was effective in preventing dental caries development. Moreover, the variables "risk" and "sealant placement" were predictors for DMFT increment in the studied children.
Sagheri, D; McLoughlin, J; Clarkson, J J
2009-03-01
The aim was to record dental caries levels and the presence of fissure sealants in 12-year-old schoolchildren whose domestic water supply had been fluoridated since birth in Dublin (Ireland). Cross-sectional study. Participants A representative, random sample of 12-year-old schoolchildren in north-west Dublin. Dental caries levels were recorded using WHO criteria and fissure sealant was recorded when sealant was detectable on a permanent molar tooth. Medical card ownership, as a surrogate for disadvantage, was recorded by use of a questionnaire. Three-hundred and thirty-two (332) children were examined. The mean DMFT was 0.80 (SD 1.24). Analysis (Mann-Whitney U test) based on stratification of the sample according to medical-card status revealed no statistically significant difference between DMFT median scores of children of medical-card holders (i.e., social disadvantage background) and non medical-card holders (p-value = 0.23). However, the data revealed a social gradient in the presence of at least one fissure sealant. Approximately 10% more children in the group of medical-card holders had no fissure sealants present. Fisher's exact test was used to examine the association between the absence of fissure sealants and at least one fissure sealant between the two groups and was considered to be statistically significant (p-value = 0.04). This study demonstrated a social gradient in the presence of fissure sealants, but no such gradient in dental caries levels. This demonstrates the importance of population-based measures in the prevention of dental caries, such as water fluoridation, in reducing oral health inequalities.
Product evaluation : Ruscoe 983 joint sealant
DOT National Transportation Integrated Search
1986-07-10
This report contains a product evaluation of Ruscoe's 983 joint sealant. Ruscoe 983 is an asphalt base single compound joint sealant. It contains an aluminum fortified adhesive and is designed for use on highway expansion joints, bridge joints, and r...
Development of the crack sealant adhesion test.
DOT National Transportation Integrated Search
2009-04-01
Crack sealants are widely used in Texas to prevent water from entering into lower structural layers thereby : extending pavement life. However, most current crack sealants have been reported to have a very short life mainly due : to adhesive failures...
PCC/AC shoulder joint seal evaluation
DOT National Transportation Integrated Search
1999-05-07
This report presents the findings on the evaluation of Crafco Incorporated Roadsaver 903 SL Silicone Sealant and Dow Corning 890 SL Silicone Sealant. The Research Technical Panel had proposed to use the two self-leveling silicone joint sealants in te...
Replacement Non-Toxic Sealants for Standard Chromated Sealants
2005-02-01
material’s mechanical or physical properties and resistance to degradation. As sealant formulations for the Class B-2 worklife were developed by PRC...results ofthis testing, Class B-1I2 and C-12 worklife materials were formulated and are being tested. In addition to the testing that UDRI conducted, two...successfully accomplished in this program. An optimized Class B-2 worklife of the sealant compound designated RW3758-71, Lot no. RT0946, completed
Tianviwat, S; Hintao, J; Chongsuvivatwong, V; Thitasomakul, S
2016-03-01
To examine whether audit and feedback could improve the quality of the application of dental sealant in rural Thai school children. A single blind, cluster randomized controlled trial was conducted. Hospital-based and school-based school sealant applied by dental nurses in Southern province of Thailand. Dental nurses and school children who received dental sealant were involved. The intervention consisted of confidential feedback of data and tailor-made problem-solving workshops. Sealant quality was measured by sealant retention and caries on sealed surfaces at six-month after sealing. The teeth examinations were done among different groups of children prior and after the intervention. After the intervention, the sealant retention rate increased dramatically in the intervention group, whereas in the control group the rate was similar to that found at baseline. The rate of caries after the intervention was stable in the intervention group and increased slightly in the control group. At the beginning of the study, the adjusted odds ratio of complete sealant retention between the intervention and control group was 0.47 which increased to 1.99 at the end of the study. However, no effect on caries on sealed surfaces was observed. The intensive focus on actual problems during the audit and feedback improved the dental nurses' performance and the quality of the dental service, although it had no statistical impact on the incidence of caries.
Parametric Study of Sealant Nozzle
NASA Astrophysics Data System (ADS)
Yamamoto, Yoshimi
It has become apparent in recent years the advancement of manufacturing processes in the aerospace industry. Sealant nozzles are a critical device in the use of fuel tank applications for optimal bonds and for ground service support and repair. Sealants has always been a challenging area for optimizing and understanding the flow patterns. A parametric study was conducted to better understand geometric effects of sealant flow and to determine whether the sealant rheology can be numerically modeled. The Star-CCM+ software was used to successfully develop the parametric model, material model, physics continua, and simulate the fluid flow for the sealant nozzle. The simulation results of Semco sealant nozzles showed the geometric effects of fluid flow patterns and the influences from conical area reduction, tip length, inlet diameter, and tip angle parameters. A smaller outlet diameter induced maximum outlet velocity at the exit, and contributed to a high pressure drop. The conical area reduction, tip angle and inlet diameter contributed most to viscosity variation phenomenon. Developing and simulating 2 different flow models (Segregated Flow and Viscous Flow) proved that both can be used to obtain comparable velocity and pressure drop results, however; differences are seen visually in the non-uniformity of the velocity and viscosity fields for the Viscous Flow Model (VFM). A comprehensive simulation setup for sealant nozzles was developed so other analysts can utilize the data.
In vivo assessment of a novel dacron surface with covalently bound recombinant hirudin.
Wyers, M C; Phaneuf, M D; Rzucidlo, E M; Contreras, M A; LoGerfo, F W; Quist, W C
1999-01-01
Prosthetic arterial graft surfaces are relatively thrombogenic and fail to heal with a cellular neointima. The goal of this study was to characterize the in vivo antithrombin properties of a novel Dacron surface with covalently linked recombinant hirudin (rHir) implanted in a canine thoracic aorta with high flow and shear rates. rHir was bound to a knitted Dacron patch using crosslinker-modified bovine serum albumin (BSA) as a basecoat protein. BSA was first reacted with the heterobifunctional crosslinker, sulfo-SMCC. This BSA-SMCC complex was then bound to the carboxylic acid groups of hydrolyzed Dacron patches using the carbodiimide crosslinker, 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide hydrochloride. Iodinated, Traut's-modified rHir (125I-rHir-SH) was then reacted with the Dacron-BSA-SMCC surface, thereby covalently binding 125I-rHir. Graft segments were washed and sonicated to remove any nonspecifically bound 125I-rHir. Dacron-BSA-SMCC-S-125I-rHir patches (n = 5) and control Dacron-BSA patches (n = 5) were implanted in series in the thoracic aortas of canines. These patches were exposed to nonheparinized, arterial blood flow for 2 hours. Patches were explanted and assessed for 125I-rHir loss. Antithrombin activity of explanted 1-cm2 patch segments was evaluated using a chromogenic assay with 1, 5, 10, 15 units of added thrombin. Light microscopy was performed to qualitatively examine the pseudointima. Two animals were excluded from the study owing to excessive bleeding through the knitted 125I-rHir patch. Comparison of preoperative and postoperative 125I-rHir gamma counts revealed an overall decrease of 20+/-5.4% over the period studied. Explanted 125I-rHir patch segments were able to inhibit 1, 5, and 7 NIHU of thrombin, demonstrating retained antithrombin activity. Gross and microscopic examination of the control and test Dacron surfaces showed marked differences. Dacron surfaces with covalently bound 125I-rHir had no gross thrombus and a thin pseudointima of platelets and plasma proteins. In contrast, the control patches had a thick pseudointima composed of fibrin-rich thrombus. rHir, covalently bound to Dacron patches, maintains its biologic activity as well as prevents thrombus formation on the graft surface. This novel antithrombin coating, by modifying the blood/ graft interface, may improve both short- and long-term patency in small-diameter prosthetic arterial grafts and has applications with respect to other implantable or indwelling biomaterials.
ReSure Sealant for Pars Plana Vitrectomy Wound Closure.
Ho, Vincent Y; Shah, Gaurav K; Liu, Enchun M
2015-01-01
ReSure Sealant (Ocular Therapeutix, Bedford, MA) is an ocular sealant that demonstrated both safety and effectiveness in a prospective, randomized clinical trial for sealing clear corneal incisions following cataract surgery and intraocular lens placement in adults.1 PATIENTS AND METHODS: This is the first literature report of ReSure Sealant used for the closure of 23-gauge (G) pars plana vitrectomy (PPV) sclerotomies. A 70-year-old pseudophakic female with a history of epiretinal membrane and branch retinal vein occlusion of the right eye underwent 23-G PPV, membrane peel, and air-fluid exchange and was found to have leaking subconjunctival air at the end of the case. A linear conjunctival incision was performed to access the sclerotomy site. The incisions were then carefully dried before the sealant was applied to seal both the sclera and conjunctiva. After polymerization, the sealant formed a polyethylene glycol (PEG) hydrogel that was 89% water and 9.44% PEG. PEG is a synthetic material that is non-toxic and inert and, thus, suitable for use in medical products. ReSure Sealant may be a safe, quick method to close sclerotomy wounds in select cases. [ Copyright 2015, SLACK Incorporated.
A comparison between three different pit and fissure sealants with regard to marginal integrity.
Fernandes, Kristlee Sabrin; Chalakkal, Paul; de Ataide, Ida de Noronha; Pavaskar, Rajdeep; Fernandes, Precylia Philo; Soni, Harleen
2012-04-01
THE AIM OF THIS STUDY IS TO COMPARE THE OCCURRENCE OF ENAMEL FRACTURES, SEALANT FRACTURES AND MARGINAL FISSURES AFTER PLACEMENT OF THREE SEALANTS: Helioseal F, Conseal F and Clinpro. Thirty individuals between 13 and 15 years of age, diagnosed with pit and fissure caries by visual and DIAGNOdent examination, were chosen for sealant placement on their mandibular molars. The sealants were placed at random, after which, impressions were made with polyvinyl siloxane and casts were fabricated. Dies were prepared, each of which were sputter coated with gold in order to be examined under a scanning electron microscope. The following morphologies were analyzed from dies from each of the sealant groups: Continuous margins, sealant fractures, marginal fissures and enamel fractures. After six months, they were recalled for impression making. Dies were prepared and microscopically analyzed as mentioned. Based on the time of evaluation, there were two groups: Initial group (soon after placement) and final group (after six months). Statistical analysis was done using the paired 't' test and One-way analysis of variance (ANOVA). Clinpro had the greatest fracture resistance, followed by Conseal F and Helioseal F. The occurrence of marginal fissure was found to be least with Clinpro.
CAUSES OF POOR SEALANT PERFORMANCE IN SOIL-GAS- RESISTANT FOUNDATIONS
The paper discusses causes of poor sealant performance in soil-gas-resistant foundations. ealants for radon-resistant foundation construction must seal the gap between concrete sections. odern sealants have such low permeability that seal performance depends only on the permeabil...
Performance of concrete joint sealants in hot climates
DOT National Transportation Integrated Search
1987-11-01
A research project was initiated in 1979 on project IR-17-1(126) to compare and evaluate several joint sealants. In 1982 another test section on project F 028-1-506 was established to evaluate several other sealants. This report documents the placeme...
High performance channel injection sealant invention abstract
NASA Technical Reports Server (NTRS)
Rosser, R. W.; Basiulis, D. I.; Salisbury, D. P. (Inventor)
1982-01-01
High performance channel sealant is based on NASA patented cyano and diamidoximine-terminated perfluoroalkylene ether prepolymers that are thermally condensed and cross linked. The sealant contains asbestos and, in its preferred embodiments, Lithofrax, to lower its thermal expansion coefficient and a phenolic metal deactivator. Extensive evaluation shows the sealant is extremely resistant to thermal degradation with an onset point of 280 C. The materials have a volatile content of 0.18%, excellent flexibility, and adherence properties, and fuel resistance. No corrosibility to aluminum or titanium was observed.
Relation Between PAHs and Coal-Tar-Based Pavement Sealant in Urban Environments (Invited)
NASA Astrophysics Data System (ADS)
Mahler, B. J.; van Metre, P. C.
2010-12-01
Since 2003, coal-tar-based sealant products have come under increased scrutiny as a source of PAHs in urban environments. Sealant (or sealcoat) is the black, shiny substance often applied to asphalt pavement, in particular parking lots and driveways, for esthetic and maintenance purposes. Coal-tar-based sealant, one of the two primary pavement sealant types on the market, typically is 20-35 percent coal-tar pitch, a known carcinogen that is more than 50 percent polycyclic aromatic hydrocarbons (PAHs). The PAH content of the coal-tar-based sealant product is about 1,000 times that of a similar, asphalt-based product, on average. This difference is reflected in regional differences in sealant use and PAH concentrations in pavement dust. In the central and eastern U.S., where the coal-tar-based formulation is prevalent, ΣPAH in mobile particles from sealed pavement have been shown to be about 1,000 times higher than in the western U.S., where the asphalt-based formulation is prevalent (the median ΣPAH concentrations are 2,200 mg/kg in the central and eastern U.S. and 2.1 mg/kg in the western U.S.). Source apportionment modeling indicates that, in the central and eastern U.S., particles from sealed pavement are contributing the majority of the PAHs in recently deposited (post-1990) lake sediment, with implications for ecological health, and that coal-tar-based sealant is the primary cause of upward trends in PAHs in U.S. urban lakes. From the standpoint of human health, research indicates that mobile particles from parking lots with coal-tar-based sealant are tracked indoors, resulting in elevated PAH concentrations in house dust. Coal-tar-based sealcoat being applied to an asphalt parking lot at the University of Texas Pickle Research Center.
Ahovuo-Saloranta, A; Hiiri, A; Nordblad, A; Worthington, H; Mäkelä, M
2004-01-01
Fissure sealants used on occlusal tooth surfaces were introduced in the 1960s for protecting pits and fissures from dental caries. Although sealants have demonstrated to be effective in preventing caries, their efficacy may be related to the background caries prevalence in the population. The primary objective of this review was to evaluate the caries prevention of resin based pit and fissure sealants and glass ionomer cements or sealants in children and adolescents. We searched the Cochrane Oral Health Group's Trials Register (last update December 2002), the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library, Issue 4, 2002), MEDLINE via OVID (1966 to December 2002), EMBASE (1974 to February 2002), SCISEARCH, SIGLE, CAplus, INSPEC, JICST-EPLUS, NTIS, PASCAL (February 2002) and DARE, NHS EED, HTA (March 2002). Reference lists from included articles and review articles were searched for additional relevant articles. All relevant studies in most languages were considered and translated. Randomised or quasi-randomised controlled trials of at least 12 months in duration in which sealants were used for preventing caries in children and adolescents under 20 years of age were included. The primary outcome was the increment in the numbers of carious occlusal surfaces of premolars and molars. In the first phase, two reviewers independently examined whether a given study was likely to be relevant on the basis of the title, key words and abstract. In the second phase, four of the reviewers independently classified studies to be included in final analyses. Study authors were contacted for additional information. In the split-mouth studies relative risk ratios were calculated for the paired differences of tooth surfaces being carious or not. In studies comparing resin based sealant with no treatment, fixed effect meta-analyses were used to combine the estimates of relative risk ratios. In one parallel group study, the mean DFS data as continuous data, the effect estimate being the difference in mean DFS, was calculated from data of occlusal surfaces of teeth included in the test and control groups. Eight trials were included in this review of which seven trials were split-mouth studies and one a parallel group study. Six studies provided data for comparing sealant with no treatment and three studies for comparing glass ionomers with resin based sealants. The overall effectiveness of resin based sealants in preventing dental decay on first molars was high. Based on five split-mouth studies with 5 to 10 year old children there were significant differences in favour of the second-generation resin sealant compared with no treatment with pooled relative risk values of 0.14, 0.24, 0.30, 0.43 at 12, 24, 36 and 48 to 54 months respectively. The reductions in caries therefore ranged from 86% at 12 months to 57% at 48 to 54 months. The 24 month parallel group study comparing second-generation resin sealant with control in 12 to 13 year old children found also significantly more caries in the control group children with DFS = 0.65 (95% CI 0.47 to 0.83). Allocation concealment was classified adequate in three of these six studies. However the information on background levels of caries in the population was insufficient to conduct further analyses to estimate the effectiveness of resin based sealants related to baseline caries prevalence. Only one study provided data for the comparison between glass ionomer sealant and control. Based on this, there is not enough information to say whether ionomer sealants are effective, or not. The results of three studies comparing resin sealants with glass ionomer sealants were conflicting and the meta-analyses were not carried out. Sealing with resin based sealants is a recommended procedure to prevent caries of the occlusal surfaces of permanent molars. However, we recommend that the caries prevalence level of both individuals and the population should be taken into account. In practice, the benefit of sealing should be considered locally and specified guidelines for clinicians should be used. The methodological quality of published studies concerning pit and fissure sealants was poorer than expected.
Impact of adhesive and photoactivation method on sealant integrity and polymer network formation.
Borges, Boniek Castillo Dutra; Pereira, Fabrício Lopes da Rocha; Alonso, Roberta Caroline Bruschi; Braz, Rodivan; Montes, Marcos Antônio Japiassú Resende; Pinheiro, Isauremi Vieira de Assunção; Santos, Alex José Souza dos
2012-01-01
We evaluated the influence of photoactivation method and hydrophobic resin (HR) application on the marginal and internal adaptation, hardness (KHN), and crosslink density (CLD) of a resin-based fissure sealant. Model fissures were created in bovine enamel fragments (n = 10) and sealed using one of the following protocols: no adhesive system + photoactivation of the sealant using continuous light (CL), no adhesive system + photoactivation of the sealant using the soft-start method (SS), HR + CL, or HR + SS. Marginal and internal gaps and KHN were assessed after storage in water for 24 h. The CLD was indirectly assessed by repeating the KHN measurement after 24 h of immersion in 100% ethanol. There was no difference among the samples with regard to marginal or internal adaptation. The KHN and CLD were similar for samples cured using either photoactivation method. Use of a hydrophobic resin prior to placement of fissure sealants and curing the sealant using the soft-start method may not provide any positive influence on integrity or crosslink density.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Wei; Kannan, Pranav; Xue, Jingchuan
Resin-based dental sealants (also referred to as pit-and-fissure sealants) have been studied for their contribution to bisphenol A (BPA) exposure in children. Nevertheless, little attention has been paid to the occurrence of other potentially toxic chemicals in dental sealants. In this study, the occurrence of six synthetic phenolic antioxidants (SPAs), including 2,6-di-tert-butyl-4-hydroxytoluene (BHT), 2,6-di-tert-butyl-4-(hydroxyethyl)phenol (BHT-OH), 3,5-di-tert-butyl-4-hydroxy-benzaldehyde (BHT-CHO), 2,6-di-tert-butylcyclohexa-2,5-diene-1,4-dione (BHT-Q), 3,5-di-tert-butyl-4-hydroxybenzoic acid (BHT-COOH) and 2-tert-butyl-4-methoxyphenol (BHA), was examined in 63 dental sealant products purchased from the U.S. market. BHT was found in all dental sealants at median and maximum concentrations of 56.8 and 1020 µg/g, respectively. The metabolites of BHT andmore » BHA were detected in 39–67% of samples, at concentration ranges of« less
DOT National Transportation Integrated Search
2011-07-01
This final report is intended to provide information regarding the performance of crack sealants supplied and installed by : three manufacturers for experimental use in a three-year evaluation of in-service pavements on three Colorado highways. : In ...
DOT National Transportation Integrated Search
2009-11-01
This interim report is intended to provide preliminary information regarding the performance of crack sealants produced by three : manufacturers during a two-year period in service in three pavements in Colorado. In addition, preliminary conclusions ...
Construction and monitoring of thin overlay and crack sealant test sections at the Pecos test track.
DOT National Transportation Integrated Search
2014-10-01
In this project, several crack sealant sections were constructed at the Pecos RTC. Six different sealants were : applied in routed and non-routed configurations on both older and newer pavement. The following summer, : the sections were revaluated in...
Wright, John T; Crall, James J; Fontana, Margherita; Gillette, E Jane; Nový, Brian B; Dhar, Vineet; Donly, Kevin; Hewlett, Edmond R; Quinonez, Rocio B; Chaffin, Jeffrey; Crespin, Matt; Iafolla, Timothy; Siegal, Mark D; Tampi, Malavika P; Graham, Laurel; Estrich, Cameron; Carrasco-Labra, Alonso
2016-08-01
This article presents evidence-based clinical recommendations for the use of pit-and-fissure sealants on the occlusal surfaces of primary and permanent molars in children and adolescents. A guideline panel convened by the American Dental Association (ADA) Council on Scientific Affairs and the American Academy of Pediatric Dentistry conducted a systematic review and formulated recommendations to address clinical questions in relation to the efficacy, retention, and potential side effects of sealants to prevent dental caries; their efficacy compared with fluoride varnishes; and a head-to-head comparison of the different types of sealant material used to prevent caries on pits and fissures of occlusal surfaces. This is an update of the ADA 2008 recommendations on the use of pit-and-fissure sealants on the occlusal surfaces of primary and permanent molars. The authors conducted a systematic search in MEDLINE, Embase, Cochrane Central Register of Controlled Trials, and other sources to identify randomized controlled trials reporting on the effect of sealants (available on the US market) when applied to the occlusal surfaces of primary and permanent molars. The authors used the Grading of Recommendations Assessment, Development, and Evaluation approach to assess the quality of the evidence and to move from the evidence to the decisions. The guideline panel formulated 3 main recommendations. They concluded that sealants are effective in preventing and arresting pit-and-fissure occlusal carious lesions of primary and permanent molars in children and adolescents compared with the nonuse of sealants or use of fluoride varnishes. They also concluded that sealants could minimize the progression of noncavitated occlusal carious lesions (also referred to as initial lesions) that receive a sealant. Finally, based on the available limited evidence, the panel was unable to provide specific recommendations on the relative merits of 1 type of sealant material over the others. These recommendations are designed to inform practitioners during the clinical decision-making process in relation to the prevention of occlusal carious lesions in children and adolescents. Clinicians are encouraged to discuss the information in this guideline with patients or the parents of patients. The authors recommend that clinicians reorient their efforts toward increasing the use of sealants on the occlusal surfaces of primary and permanent molars in children and adolescents. Copyright © 2016 American Academy of Pediatric Dentistry and American Dental Association. Published by Elsevier Inc. All rights reserved.
Durability of building joint sealants
Christopher C. White; Kar Tean Tan; Donald L. Hunston; R. Sam Williams
2009-01-01
Predicting the service life of building joint sealants exposed to service environments in less than real time has been a need of the sealant community for many decades. Despite extensive research efforts to design laboratory accelerated tests to duplicate the failure modes occurring in field exposures, little success has been achieved using conventional durability...
The Maine Sealant Manual for School-Based and School-Linked Dental Sealant Programs.
ERIC Educational Resources Information Center
Hayward, Kneka, Ed.
This manual is designed for use by school personnel and dental personnel to aid in the development and maintenance of school-based or school-linked dental sealant programs. The sections include (1) "Introduction"; (2) "Guidelines" (school selection, school contacts, dental providers, target grades, and tooth selection…
Light weight phosphate cements
Wagh, Arun S.; Natarajan, Ramkumar,; Kahn, David
2010-03-09
A sealant having a specific gravity in the range of from about 0.7 to about 1.6 for heavy oil and/or coal bed methane fields is disclosed. The sealant has a binder including an oxide or hydroxide of Al or of Fe and a phosphoric acid solution. The binder may have MgO or an oxide of Fe and/or an acid phosphate. The binder is present from about 20 to about 50% by weight of the sealant with a lightweight additive present in the range of from about 1 to about 10% by weight of said sealant, a filler, and water sufficient to provide chemically bound water present in the range of from about 9 to about 36% by weight of the sealant when set. A porous ceramic is also disclosed.
Sealants in dentistry: a systematic review of the literature.
Condò, R; Cioffi, A; Riccio, A; Totino, M; Condò, S G; Cerroni, L
2013-03-01
The occlusal surface is the most affected area by dental caries and the sealing of the pits and of the fissures has been found, in time, the preventive method most effective trying to counteract the onset. Currently, the WHO considers it as a primary preventive measure, in other words one of the most effective and least invasive available to ensure the complete protection and the total preservation of the occlusal carious by the phenomenon. THE AIM OF THIS WORK HAS BEEN TO PERFORM A SYSTEMATIC REVIEW OF THE LITERATURE ON CLINICAL TRIALS OF DIFFERENT SEALING MATERIALS, IN ORDER TO: compare their individual characteristics, highlight the reliability and the long-term efficacy and identify the most significant variables, both technological and clinics, in order to declare whether or not the success of this method prior. The research has been carried out in the MEDLINE database by choosing keywords as "sealants" and "follow up". Only studies published in the last thirteen years have been considered and have been evaluated only types of scientific articles that fall within the definition of Anglo-Saxon "Clinical Trial" and "Controlled Clinical Trial", excluding all experimental works in vitro, case-reports, meta-analyzes and literature reviews. Have been also considered only scientific papers on patients between the ages of 0 and 18 years. Out of 29 studies, evaluating a total of 2900 individuals (aged between 2.5 and 17 years), 7411 seals made by using resin-based sealants (RB Sealants), modified glass ionomer sealants (RMGI) and compomer sealants have been analyzed. The best retention capacity of the material in time has been obtained from the use of RB Sealants compared to RMGI, demonstrating retention values much lower with partial loss of material at a distance of one year from the clinic. The compomers demonstrate retention values intermediates. The incidence of caries in a year is negligible for all sealants application. In terms of retention, resin-based sealants (RB Sealants) are the materials that give more guarantees of success at 12 months, while in the same period there haven't been significant differences in caries prevention of disease among the various classes sealing materials analyzed.
First Permanent Molar Restoration Differences between Those with or without Dental Sealants.
ERIC Educational Resources Information Center
Kuthy, Raymond A.; And Others
1990-01-01
The study examined differences in the number of restorations in permanent, posterior teeth for those children receiving dental sealants with cost sharing when compared to children who do not receive sealants. Results indicated a 51 percent reduction in restoration rates for each quadrant sealed. Findings have implications for cost savings and…
21 CFR 872.3765 - Pit and fissure sealant and conditioner.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pit and fissure sealant and conditioner. 872.3765 Section 872.3765 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... conditioner. (a) Identification. A pit and fissure sealant and conditioner is a device composed of resin, such...
21 CFR 872.3765 - Pit and fissure sealant and conditioner.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Pit and fissure sealant and conditioner. 872.3765 Section 872.3765 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... conditioner. (a) Identification. A pit and fissure sealant and conditioner is a device composed of resin, such...
21 CFR 872.3765 - Pit and fissure sealant and conditioner.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Pit and fissure sealant and conditioner. 872.3765 Section 872.3765 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3765 Pit and fissure sealant and...
The economics of pit and fissure sealants in preventive dentistry: a review.
Kitchens, Dinah H
2005-08-15
Oral diseases are progressive, cumulative, and become more intricate to treat with advancement. While dental caries is an infectious transmissible disease with children being at the highest risk, primary prevention can reduce this risk. Primary prevention in dentistry is usually considered to be community fluoridated water supplies, professional fluoride treatments, and pit and fissure sealants. While community fluoridated water supplies have been proven to be cost-effective, the cost-effectiveness of pit and fissure sealants has primarily been studied in school-based programs of children from low socio-economic backgrounds. Dental sealant programs are just one way to help increase primary prevention in the oral health disparities of children. The purpose of this paper is to review the literature regarding the cost-effectiveness of pit and fissure sealants as a preventive strategy in preventive dentistry.
Souza-Junior, Eduardo José; Borges, Boniek Castillo Dutra; Montes, Marcos Antônio Japiassú Resende; Alonso, Roberta Caroline Bruschi; Ambrosano, Glaucia Maria Bovi; Sinhoreti, Mário Alexandre Coelho
2012-01-01
This study evaluated the impact of extended etching and bonding strategies on the microshear bond strength of three sealant materials. Two pit-and-fissure sealants [FluroShield, Dentsply (light-cured) and AlphaSeal, DFL (self-cured)] and one light-cured flowable composite resin (Permaflo, Ultradent) were evaluated according to different enamel etching times (15 s or 30 s) and bonding procedures (no adhesive application, application of primer/hydrophobic resin or hydrophobic resin only). Intact enamel blocks were obtained from bovine teeth and sealed via the tested protocols. After 24 h, the microshear bond strength test was performed in a universal testing machine at a crosshead speed of 0.5 mm/min. Failure modes were classified by stereomicroscopy. Data were submitted to a three-way ANOVA and to Tukey's test (α=0.05). There was no statistically significant difference (p>0.05) among the materials. Permaflo showed higher bond strength when etched for 30 s alone. Enamel overetching decreased the bond strength of the light-cured sealant. Primer/bond previous treatment improved bond performance for AlphaSeal. In conclusion, from the tested conditions, all sealant materials presented similar bond strength values in relation to bonding protocol and etching time. The flowable composite can be used as a pit-and-fissure sealant. The use of a three-step adhesive system was essential for the self-cured sealant application.
Evaluation of a hydrophilic gingival dental sealant in beagle dogs.
Sitzman, Clarence
2013-01-01
A liquid solution, gingival sealant containing polymers that form a barrier film upon application was evaluated in dogs. It is a non-toxic, low viscosity, hydrophilic barrier sealant that dries in approximately 10 to 15-seconds after subgingival application. It was designed as a preventative to be applied immediately following a professional oral hygiene procedure in order to block plaque and calculus formation in the sulcus and aid in the prevention of periodontal disease in companion animals. Additionally, the polymer was designed to promote an aerobic environment in the sulcus by oxygen and water transport through engineered pores within the polymer. A 30-day split-mouth, blinded study in two groups of 15 beagle dogs was used. Plaque was significantly (p < 0.05) reduced on the side receiving the sealant by 30.0% and 50.5% (average = 40.3%) in groups 1 and 2, respectively. Calculus was significantly (p < 0.05) reduced on the side receiving the sealant by 27.2% and 20.0% (average = 23.6%) in groups 1 and 2, respectively. Gingival inflammation was monitored to assess product safety. Sides receiving sealant showed no statistically significant differences in gingival index score. No adverse events were observed in the study. This study demonstrates that this gingival sealant can be used as another valuable tool for aiding in the prevention of periodontal disease in dogs.
Cotton roll isolation versus Vac-Ejector isolation.
Wood, A J; Saravia, M E; Farrington, F H
1989-01-01
A visible-light-cured, white pit-and-fissure sealant was applied to 523 teeth in school children using either cotton rolls or a VacEjector for isolation. After a minimum of six months, the patients were recalled and the retention of the sealants was evaluated. No significant difference in sealant retention was found between the two isolation methods.
Adhesion mechanisms of bituminous crack sealant to aggregate and laboratory test development
NASA Astrophysics Data System (ADS)
Hajialiakbari Fini, Elham
Crack sealing is a common pavement maintenance treatment because it extends pavement service life. However, crack sealant often fails prematurely due to a loss of adhesion. Since current test methods are mostly empirical and only provide a qualitative measure of bond strength, they cannot predict sealant adhesive failure accurately. Hence, there is an urgent need for test methods based on bituminous sealant rheology that can better predict sealant field performance. This study introduces three laboratory tests aimed to assess the bond property of hot-poured crack sealant to pavement crack walls. The three tests are designed to serve the respective needs of producers, engineers, and researchers. The first test implements the principle of surface energy to measure the thermodynamic work of adhesion, which is the energy spent in separating the two materials at the interface. The work of adhesion is reported as a measure of material compatibility at an interface. The second test is a direct adhesion test, a mechanical test which is designed to closely resemble both the installation process and the crack expansion due to thermal loading. This test uses the Direct Tension Test (DTT) device. The principle of the test is to apply a tensile force to detach the sealant from its aggregate counterpart. The maximum load, Pmax, and the energy to separation, E, are calculated and reported to indicate interface bonding. The third test implements the principles of fracture mechanics in a pressurized circular blister test. The apparatus is specifically designed to conduct the test for bituminous crack sealant, asphalt binder, or other bitumen-based materials. In this test, a fluid is injected at a constant rate at the interface between the substrate (aggregate or a standard material) and the adhesive (crack sealant) to create a blister. The fluid pressure and blister height are measured as functions of time; the data is used to calculate Interfacial Fracture Energy (IFE), which is a fundamental property that can be used to predict adhesion. The stable interface debonding process makes this test attractive. This test also may be used to estimate the optimum annealing time, and to quantify other interface characteristics, such as the moisture susceptibility of a bond. In addition, the elastic modulus of the sealant and its residual stresses can be determined analytically. While the direct adhesion test is proposed as part of newly-developed performance-based guidelines for the selection of hot-poured crack sealant, the blister test may be used to estimate the optimum annealing time, in addition to IFE determination.
Monse, Bella; Heinrich-Weltzien, Roswitha; Mulder, Jan; Holmgren, Christopher; van Palenstein Helderman, Wim H
2012-11-21
Occlusal surfaces of erupting and newly erupted permanent molars are particularly susceptible to caries.The objective of the study was to assess and compare the effect of a single application of 38% SDF with ART sealants and no treatment in preventing dentinal (D3) caries lesions on occlusal surfaces of permanent first molars of school children who participated in a daily school-based toothbrushing program with fluoride toothpaste. The prospective community clinical trial in the Philippines was conducted over a period of 18 months and included 704 six- to eight-year-old school children in eight public elementary schools with a daily school-based fluoride toothpaste brushing program. Children were randomly assigned for SDF application or ART sealant treatment. Children from two of the eight schools did not receive SDF or ART sealant treatment and served as controls. SDF or ART sealant treatment was applied on sound occlusal surfaces of permanent first molars. Surfaces that were originally defined as sound at baseline but which changed to dentinal (D3) caries lesions were defined as surfaces with new caries (caries increment). Non-compliance to the daily toothbrushing program in three schools offered the opportunity to analyze the caries preventive effect of SDF and sealants separately in fluoride toothpaste brushing and in non-toothbrushing children. In the brushing group, caries increment in the SDF treatment group was comparable with the non-treatment group but caries increment in the sealant group was lower than in the non-treatment group with a statistically significant lower hazard ratio of 0.12 (0.02-0.61). In the non-brushing group, caries increment in the SDF treatment group and the sealant group was lower than the non-treatment group but the hazard ratio was only statistically significant for the sealant group (HR 0.33; 0.20-0.54). Caries increment was lower in toothbrushing children than in non-toothbrushing children. Hazard ratios reached statistical significance for the non-treated children (HR 0.43; 0.21-0.87) and the sealant-treated children (HR 0.15; 0.03-0.072). A one-time application of 38% SDF on the occlusal surfaces of permanent first molars of six- to eight-year-old children is not an effective method to prevent dentinal (D3) caries lesions. ART sealants significantly reduced the onset of caries over a period of 18 months. German Clinical Trial Register DRKS00003427.
2012-01-01
Background Occlusal surfaces of erupting and newly erupted permanent molars are particularly susceptible to caries. The objective of the study was to assess and compare the effect of a single application of 38% SDF with ART sealants and no treatment in preventing dentinal (D3) caries lesions on occlusal surfaces of permanent first molars of school children who participated in a daily school-based toothbrushing program with fluoride toothpaste. Methods The prospective community clinical trial in the Philippines was conducted over a period of 18 months and included 704 six- to eight-year-old school children in eight public elementary schools with a daily school-based fluoride toothpaste brushing program. Children were randomly assigned for SDF application or ART sealant treatment. Children from two of the eight schools did not receive SDF or ART sealant treatment and served as controls. SDF or ART sealant treatment was applied on sound occlusal surfaces of permanent first molars. Surfaces that were originally defined as sound at baseline but which changed to dentinal (D3) caries lesions were defined as surfaces with new caries (caries increment). Non-compliance to the daily toothbrushing program in three schools offered the opportunity to analyze the caries preventive effect of SDF and sealants separately in fluoride toothpaste brushing and in non-toothbrushing children. Results In the brushing group, caries increment in the SDF treatment group was comparable with the non-treatment group but caries increment in the sealant group was lower than in the non-treatment group with a statistically significant lower hazard ratio of 0.12 (0.02-0.61). In the non-brushing group, caries increment in the SDF treatment group and the sealant group was lower than the non-treatment group but the hazard ratio was only statistically significant for the sealant group (HR 0.33; 0.20-0.54). Caries increment was lower in toothbrushing children than in non-toothbrushing children. Hazard ratios reached statistical significance for the non-treated children (HR 0.43; 0.21-0.87) and the sealant-treated children (HR 0.15; 0.03-0.072). Conclusions A one-time application of 38% SDF on the occlusal surfaces of permanent first molars of six- to eight-year-old children is not an effective method to prevent dentinal (D3) caries lesions. ART sealants significantly reduced the onset of caries over a period of 18 months. Trial registration number German Clinical Trial Register DRKS00003427 PMID:23171244
Selective removal of composite sealants with near-UV laser pulses
NASA Astrophysics Data System (ADS)
Louie, Tiffany M.; Jones, Robert S.; Sarma, Anupama V.; Fried, Daniel
2004-05-01
It is often necessary to replace pit and fissure sealants and composite restorations. This task is complicated by the necessity for complete removal of the remaining composite to enable suitable adhesion of new composite. Previous studies have shown that lasers pulses from a frequency-tripled Nd:YAG laser (355-nm) can selectively remove residual composite after orthodontic bracket removal on enamel surfaces. UV laser light is preferentially absorbed by polymeric resins and the organic content of the tooth enamel. The objective of this study was to determine if such laser pulses are suitable for selective removal of the old composite from pit and fissure sealants and restorations without damaging surrounding sound tissues. Optical coherence tomography was used to acquire optical cross sections of the occlusal topography and peripheral tooth structure non-destructively before application of the sealants, after sealant application, and after sealant removal with 355-nm laser pulses with intensities ranging from 0-10 J/cm2. Thermocouples were used to monitor the temperature in the pulp chamber during composite removal under clinically relevant ablation rates, i.e., 30 Hz and 30 mJ per laser pulse. At an irradiation intensity of 1.3 J/cm2 pit and fissure sealants were completely removed without visible damage to the underlying enamel. At intensities above 1.5 J/cm2, the laser removes the resin layer while at the same time preferentially etching the surface of the enamel. Temperature excursions in the pulp chamber of extracted teeth was limited to less than 5°C if air-cooling was used during the rapid removal (1-2 min) of sealants, water-cooling was not needed. This is the first presentation of a method for the selective removal of composite restorative materials without damage to the underlying sound tooth structure.
Bakhshandeh, Azam; Qvist, Vibeke; Ekstrand, Kim R
2012-04-01
The aim of this study was to assess the possibility to arrest occlusal caries lesions in adults by sealant as well as to assess the presence of radiographic progression, arrest, and regression of the sealed lesions. Seventy-two occlusal caries lesions in 52 adult patients referred to restorative treatment by senior lecturers at School of Dentistry, Copenhagen, Denmark were included. In case the patient had more than one occlusal caries lesion, randomization between sealing and restoration was made; otherwise, the lesion was sealed. In total, 60 resin sealants and 12 composite restorations were made. Follow-up period was 25-38 months (mean = 33 months). Data were analyzed using non-parametric statistics including kappa statistics. After 2-3 years, the dropout rate was 15%; two patients did not show up for control and nine previously sealed lesions were restored by the patients' general practitioners. All 12 restorations and 39 of the remaining 49 sealants were well functioning, seven (14%) sealants were repaired/replaced due to failure, and three (6%) sealed lesions were restored due to caries progression (p > 0.05). The radiographic assessment showed caries progression beneath five (10%) sealants, caries regression beneath one (2%) sealant, and unchanged depth beneath 43 (88%) sealants and all restorations (p > 0.05). The majority of the referred lesions were successfully arrested by sealants, indicating the possibility for extending the criteria for sealing occlusal caries lesions in adults. However, a longer observation period is needed for final conclusion. Extending the criteria of therapeutic sealing of occlusal caries lesions in adults will lead to increased dental health.
Zamolodchikov, Daria
2012-01-01
Alzheimer disease is characterized by the presence of increased levels of the β-amyloid peptide (Aβ) in the brain parenchyma and cerebral blood vessels. This accumulated Aβ can bind to fibrin(ogen) and render fibrin clots more resistant to degradation. Here, we demonstrate that Aβ42 specifically binds to fibrin and induces a tighter fibrin network characterized by thinner fibers and increased resistance to lysis. However, Aβ42-induced structural changes cannot be the sole mechanism of delayed lysis because Aβ overlaid on normal preformed clots also binds to fibrin and delays lysis without altering clot structure. In this regard, we show that Aβ interferes with the binding of plasminogen to fibrin, which could impair plasmin generation and fibrin degradation. Indeed, plasmin generation by tissue plasminogen activator (tPA), but not streptokinase, is slowed in fibrin clots containing Aβ42, and clot lysis by plasmin, but not trypsin, is delayed. Notably, plasmin and tPA activities, as well as tPA-dependent generation of plasmin in solution, are not decreased in the presence of Aβ42. Our results indicate the existence of 2 mechanisms of Aβ42 involvement in delayed fibrinolysis: (1) through the induction of a tighter fibrin network composed of thinner fibers, and (2) through inhibition of plasmin(ogen)–fibrin binding. PMID:22238323
Repair of Inaccessible Ventral Dural Defect in Thoracic Spine: Double Layered Duraplasty
Lee, Dong-Hyun; Park, Jeong-Ill; Park, Ki-Su; Cho, Dae-Chul; Sung, Joo-Kyung
2016-01-01
We propose a double layered (intradural and epidural patch) duraplasty that utilizes Lyoplant and Duraseal. We examined a 47-year-old woman after decompression for thoracic ossification of posterior longitudinal ligament was performed in another hospital. On postoperative day 7, she complained of weakness in both legs. Postoperative magnetic resonance imaging (MRI) showed cerebrospinal fluid (CSF) collection with cord compression. In the operative field, we found 2 large dural defects on the ventral dura mater. We performed a conventional fat graft with fibrin glue. However, the patient exhibited neurologic deterioration, and a postoperative MRI again showed CSF collection. We performed dorsal midline durotomy and inserted a intradural and epidural Lyoplant patch. She immediately experienced diminishing back pain postoperatively. Her visual analog scale and motor power improved markedly. Postoperative MRIs performed at 2 and 16 months showed no spinal cord compression or CSF leakage to the epidural space. We describe a new technique for double layered duraplasty. Although we do not recommend this technique for all dural repairs, double-layered duraplasty may be useful for repairing large inaccessible dural tears in cases of persistent CSF leakage refractory to conventional management. PMID:27437022
Comparison of fibrin clots derived from peripheral blood and bone marrow.
Shoji, Takeshi; Nakasa, Tomoyuki; Yoshizuka, Masaaki; Yamasaki, Takuma; Yasunaga, Yuji; Adachi, Nobuo; Ochi, Mitsuo
2017-03-01
Autologous fibrin clots derived from peripheral blood (pb-fibrin clot) and bone marrow (bm-fibrin clot) are thought to be effective for tissue regeneration. However, there is no report detailing the amount of growth factors in pb-/bm-fibrin clot. In this study we evaluated the amount of growth factors in human pb-/bm-fibrin clot, and prove the validity of fibrin clot for clinical use. Human pb-/bm-fibrin clots were obtained during surgery. In the first experiment, enzyme-linked immunosorbent assay (ELISA) was performed for detecting the amount of vascular endothelial growth factor (VEGF), epidermal growth factor (EGF), insulin-like growth factor-1 (IGF-1), fibroblast growth factor basic (bFGF), hepatocyte growth factor (HGF), transforming growth factor-beta (TGF-β), platelet derived-growth factors-AB (PDGF-AB), and stromal cell-derived factor-1 (SDF-1). In the second experiment, the efficacy of fibrin clot on the osteogenic differentiation and fibroblast proliferation was evaluated. Pb-/bm-fibrin clots were incubated in human osteoblast derived from mesenchymal stromal cells (MSCs) or human skin fibroblast. Alizarin red staining and real-time PCR (COL1A1, RUNX2) were performed for the detection of osteogenic potential. Cell-growth assay (WST-8) and real-time PCR (COL1A1) were also performed for the detection of the potential of fibroblast proliferation. ELISA analysis revealed that the amount of VEGF, HGF, bFGF, IGF-1, and SDF-1 of bm-fibrin clot group is higher than that of pb-fibrin clot group with statistical differences. Besides, we confirmed that bm-fibrin clot has much potential for the osteogenic differentiation and fibroblast proliferation. The positive outcomes confirm the efficacy of pb-/bm-fibrin clot, and bm-fibrin clot was proved to have much potential for tissue regeneration compared with pb-fibrin clot. The current study showed the potential of a strategy for regenerative medicine using bm-fibrin clot.
Design, development, and testing of a hybrid in situ testing device for building joint sealant
C. White; N. Embree; C. Buch; R.S. Williams
2005-01-01
The testing of sealant samples has been restricted to devices that either focus on fatiguing multiple samples or quantifying the mechanical properties of a single sample. This manuscript describes a device that combines these two instrumental designs: the ability to both fatigue and characterize multiple sealant samples at the same time. This device employs precise...
Fibronectin alters the rate of formation and structure of the fibrin matrix.
Ramanathan, Anand; Karuri, Nancy
2014-01-10
Plasma fibronectin is a vital component of the fibrin clot; however its role on clot structure is not clearly understood. The goal of this study was to examine the influence of fibronectin on the kinetics of formation, structural characteristics and composition of reconstituted fibrin clots or fibrin matrices. Fibrin matrices were formed by adding thrombin to 1, 2 or 4 mg/ml fibrinogen supplemented with 0-0.4 mg/ml fibronectin. The rate of fibrin matrix formation was then monitored by measuring light absorbance properties at different time points. Confocal microscopy of fluorescein conjugated fibrinogen was used to visualize the structural characteristics of fibrin matrices. The amount of fibronectin in fibrin matrices was determined through electrophoresis and immunoblotting of solubilized matrices. Fibronectin concentration positively correlated with the initial rate of fibrin matrix formation and with steady state light absorbance values of fibrin matrices. An increase in fibronectin concentration resulted in thinner and denser fibers in the fibrin matrices. Electrophoresis and immunoblotting showed that fibronectin was covalently and non-covalently bound to fibrin matrices and in the form of high molecular weight multimers. The formation of fibronectin multimers was attributed to cross-linking of fibronectin by trace amounts Factor XIIIa. These findings are novel because they link results from light absorbance studies to microcopy analyses and demonstrate an influence of fibronectin on fibrin matrix structural characteristics. This data is important in developing therapies that destabilize fibrin clots. Copyright © 2014. Published by Elsevier Inc.
Treating pain on skin graft donor sites: Review and clinical recommendations.
Sinha, Sarthak; Schreiner, Amanda J; Biernaskie, Jeff; Nickerson, Duncan; Gabriel, Vincent A
2017-11-01
Split-thickness skin grafting is the most common reconstructive procedure in managing burn injuries. Harvesting split-thickness skin creates a new partial thickness wound referred to as the donor site. Pain at the donor site is reported to be one of the most distressing symptoms during the early postoperative period. Here, we (a) identify strategies for managing donor site pain, (b) assess the quality of individual studies, and (c) formulate evidence-based recommendations based on the amount and consistency of evidence. Our analysis revealed five distinct approaches to minimize donor site pain. These include: continuous subcutaneous local anesthetic infusion (three studies), subcutaneous anesthetic injection (five studies), topical agents (six studies), nonpharmacological interventions (three studies), and wound dressings (18 studies). Available randomized control trials typically evaluated pain on standardized scales (i.e. Visual Analog Scale, Numerical Rating Scale), and compared the experimental group with standard care. Recommended treatments include: (a) subcutaneous anesthetic injection of adrenaline-lidocaine; (b) ice application; (c) topical agents, such as lidocaine and bupivacaine; and (d) hydrocolloid- and polyurethane-based wound dressings accompanied with fibrin sealant. Methodologically sound randomized control trials examining the efficacy of modified tumescent solution, ropivacaine, plasma therapy, noncontact ultrasound, and morphine gels are lacking and should be a priority for future research.
Maserejian, Nancy N; Shrader, Peter; Trachtenberg, Felicia L; Hauser, Russ; Bellinger, David C; Tavares, Mary
2014-01-01
Dental sealant materials may intraorally release their components, including bisphenol-A (BPA), but long-term health effects are uncertain. The New England Children's Amalgam Trial (NECAT) found that composite restorations were associated with psychosocial, but not neuropsychological or physical, outcomes. The previous analysis did not consider sealants and preventive resin restorations (PRRs), which were routinely placed. The purpose of this analysis was to examine sealant/PRR exposure in association with psychosocial and other health outcomes. NECAT recruited 534 six- to 10-year-olds and provided dental care during a five-year follow-up. Annually, examiners conducted psychosocial and neuropsychological tests and measured body mass index (BMI) and fat percentage (BF%). Associations between surface years (SY) of sealants/PRRs and outcomes were tested using multivariable models. Cumulative exposure level to sealants and/or PRRs was not associated with psychosocial assessments (eg, total problems: Child Behavior Checklist, 10-SY β=-0.2 ± 0.3, P=.60) or neuropsychological tests (eg, full-scale IQ, 10-SY β=0.1 ± 0.2, P=.60). There were no associations for changes in BMI-for-age z-score (P=.40), BF% (girls 10-SY β=-0.2 ± 0.3; boys 10-SY β=-0.1 ± 0.3), or menarche (10-SY hazard ratio=0.91, 95% confidence interval=0.83-1.01, P=.08). This study showed no associations between exposure level of dental sealants or PRRs and behavioral, neuropsychological, or physical development in children over 5-years.
Biomimetic chimeric peptide-tethered hydrogels for human mesenchymal stem cell delivery.
Shim, Gayong; Kim, Gunwoo; Choi, Junhyeok; Yi, TacGhee; Cho, Yun Kyoung; Song, Sun Uk; Byun, Youngro; Oh, Yu-Kyoung
2015-12-01
Here, we report a chimeric peptide-tethered fibrin hydrogel scaffold for delivery of human mesenchymal stem cells (hMSC). Osteopontin-derived peptide (OP) was used as an hMSC-tethering moiety. OP showed hMSC adhesion properties and enhanced hMSC proliferation. A natural fibrin-binding protein-derived peptide (FBP) was tested for its ability to tether hMSC to the fibrin gel matrix. FBP loading on fibrin gels was 8.2-fold higher than that of a scrambled peptide (scFBP). FBP-loaded fibrin gels were retained at injection sites longer than scFBP-loaded fibrin gels, showing a 15.9-fold higher photon intensity of fluorescent FBP-grafted fibrin gels than fluorescent scFBP-loaded fibrin gels 48 h after injection. On the basis of the fibrin gel-binding properties of FBP and the hMSC-binding and proliferation-supporting properties of OP, we constructed chimeric peptides containing FBP and OP linked with a spacer (FBPsOP). Four days after transplantation, the survival of hMSC in FBPsOP-grafted fibrin gels was 3.9-fold higher than hMSC in fibrin gels alone. Our results suggest the potential of FBPsOP-grafted fibrin gels as a bioactive delivery system for enhanced survival of stem cells. Copyright © 2015 Elsevier B.V. All rights reserved.
Pneumostasis of experimental air leaks with a new photopolymerized synthetic tissue sealant.
Ranger, W R; Halpin, D; Sawhney, A S; Lyman, M; Locicero, J
1997-09-01
Air leak is a major contributor to increased length of stay and postoperative morbidity following pulmonary surgery. The effectiveness of a new photopolymerized synthetic hydrogel (FocalSeal, Focal, Inc., Lexington, MA) as a sealant for pulmonary air leaks was determined in 10 mongrel dogs (20-35 kg). The animals were anesthetized and underwent left-sided anterolateral thoracotomy with amputation of a 2 x 3-cm segment of the lung apex. Hemostasis was achieved and terminal bronchial openings of 1.5 to 3 mm with vigorous air leaks were identified. After successful injury, the dogs were randomly assigned to sealant (n = 5) or control (n = 5) groups. In treated animals, the sealant was applied by brushing the solution to the cut parenchymal surface and solidified while briefly interrupting ventilation (40-60 seconds) using visible illumination (450-550 nm) from a xenon light source. Controls received no sealant. A single chest tube was maintained at the injury site with a continuous negative pressure of 20 cm of water. All dogs were extubated and allowed to breathe spontaneously under sedation for 24 hours. Chest radiographs were taken postsurgery and presacrifice. All control animals (n = 5) showed persistent vigorous air leak for the duration of the 24-hour observation period. All treated air leaks resolved immediately, and four of five remained sealed throughout the observation period. One leak reappeared after 17 hours due to inadequate sealant thickness over a 3-mm terminal bronchus. Gross evaluation of the treatment group at the end of 24 hours demonstrated intact sealant well adherent to the parenchyma. No evidence of atelectasis or excessive edema was seen, and no sealant-related complications or toxic effects were noted. Radiologically, lungs were fully inflated. Histologic evaluation at 24 hours revealed no evidence of a strong cellular response to the synthetic sealant, and no fibrosis or adhesions were seen, the onset of the healing process was favorable, indicating good biocompatability. In conclusion, this material was found to be an effective means for sealing bronchial and parenchymal air leaks in this model and warrants clinical evaluation.
Knösel, Michael; Ellenberger, David; Göldner, Yvonne; Sandoval, Paulo; Wiechmann, Dirk
2015-04-15
Sealant application during fixed appliances orthodontic treatment for enamel protection is common, however, reliable data on its durability in vivo are rare. This study aims at assessing the durability of a sealant (OpalSeal, Ultradent) for protection against white-spot lesion formation in orthodontic patients over 26 weeks in vivo, taking into account the provision or absence of an adequate oral hygiene. We tested the null hypothesis of (1) no significant abatement of the sealant after 26 weeks in fixed orthodontic treatment compared to baseline, and (2) no significant influence of the factor of brushing and oral hygiene (as screened by approximal plaque index, API) on the abatement of the sealant. Integrity and abatement of OpalSeal applicated directly following bracketing was assessed in thirty-six consecutive patients (n(teeth) = 796) undergoing orthodontic treatment with fixed appliances (male/female 12/24; mean age/SD 14.4/1.33 Y). Assessment of the fluorescing sealant preservation was by a black-light lamp, using a classification that was concepted in analogy to the ARI index: (3, sealant completely preserved; 2= > 50% preserved; 1 = <50%; 0 = no sealant observable) immediately following application (Baseline, T0), after 2 (T1), 8 (T2), 14 (T3), 20 (T4) and 26 weeks (T5). API was assessed at T0 and T1. Statistical analysis was by non-parametric repeated measures ANOVA (α = 5%, power >80%). At baseline, 43.4% of teeth had a positive API. Oral hygiene deteriorated after bracketing (T1, 53%) significantly. Null hypothesis (1) was rejected, while (2) was accepted: Mean values of both the well brushed and non-brushed anterior teeth undercut the score "1" at T3 (week 14). Despite a slightly better preservation of the sealer before and after T3 in not-sufficiently brushed (API-positive) teeth, this finding was statistically not significant. One single application of OpalSeal is unlikely to last throughout the entire fixed appliance treatment stage. On average, re-application of the sealant can be expected to be necessary after 3.5 months (week 14) in treatment.
Tolls, Johannes; Gómez, Divina; Guhl, Walter; Funk, Torsten; Seger, Erich; Wind, Thorsten
2016-01-01
Regulation (EC) No 1907/2006 concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH) requires that environmental exposure assessments be performed for all uses of dangerous substances that are marketed in the European Union in quantities above 10 tons per year. The quantification of emissions to the environment is a key step in this process. This publication describes the derivation of release factors and gives guidance for estimating use rates for quantifying the emissions from the manufacturing and application of adhesives and sealants. Release factors available for coatings and paints are read across to adhesives or sealants based on similarities between these 2 product groups with regard to chemical composition and to processing during manufacturing and application. The granular emission scenarios in these documents are mapped to the broad emission scenarios for adhesives or sealants. According to the mapping, the worst-case release factors for coatings or paints are identified and assigned to the adhesives or sealants scenarios. The resulting 10 specific environmental release categories (SPERCs) for adhesives and sealants are defined by differentiating between solvent and nonsolvent ingredients and between water-borne and solvent-borne or solvent-free products. These cover the vast majority of the production processes and uses and are more realistic than the 5 relevant emission estimation defaults provided in the REACH guidance. They are accompanied with adhesive or sealant consumption rates in the EU and with guidance for estimating conservative substance use rates at a generic level. The approach of combining conservative SPERC release factors with conservative estimates of substance rates is likely to yield emission estimates that tend to overpredict actual releases. Because this qualifies the approach for use in lower-tier environmental exposure assessment, the Association of the European Adhesive & Sealant Industry (FEICA) SPERCs are available in several exposure assessment tools that are used under REACH. Given the limited regional variation in the manufacturing and use processes of adhesives and sealants, the SPERCs may be applicable for emission estimation not only in the EU but also in other regions. © 2015 SETAC.
Pathophysiology and management of spontaneous intracranial hypotension--a review.
Syed, Nadir Ali; Mirza, Farhan Arshad; Pabaney, Aqueel Hussain; Rameez-ul-Hassan
2012-01-01
Spontaneous Intracranial Hypotension is a syndrome involving reduced intracranial pressure secondary to a dural tear which occurs mostly due to connective tissue disorders such as Marfans Syndrome, and Ehler Danlos Syndrome. Patients with dural ectasias leading to CSF leakage into the subdural or epidural space classically present with orthostatic headaches and cranial nerve deficits mostly seen in cranial nerves V-VIII. Diagnosis of SIH is confirmed with the aid of neuroimaging modalities of which Cranial MR imaging is most widely used. SIH can be treated conservatively or with epidural blood patches which are now widely being used to repair dural tears, and their effectiveness is being recognized. Recently epidural injection of fibrin glue has also been used which has been found to be effective in certain patients.
Zhu, Shu; Lu, Yichen; Sinno, Talid; Diamond, Scott L
2016-10-28
Coagulation kinetics are well established for purified blood proteases or human plasma clotting isotropically. However, less is known about thrombin generation kinetics and transport within blood clots formed under hemodynamic flow. Using microfluidic perfusion (wall shear rate, 200 s -1 ) of corn trypsin inhibitor-treated whole blood over a 250-μm long patch of type I fibrillar collagen/lipidated tissue factor (TF; ∼1 TF molecule/μm 2 ), we measured thrombin released from clots using thrombin-antithrombin immunoassay. The majority (>85%) of generated thrombin was captured by intrathrombus fibrin as thrombin-antithrombin was largely undetectable in the effluent unless Gly-Pro-Arg-Pro (GPRP) was added to block fibrin polymerization. With GPRP present, the flux of thrombin increased to ∼0.5 × 10 -12 nmol/μm 2 -s over the first 500 s of perfusion and then further increased by ∼2-3-fold over the next 300 s. The increased thrombin flux after 500 s was blocked by anti-FXIa antibody (O1A6), consistent with thrombin-feedback activation of FXI. Over the first 500 s, ∼92,000 molecules of thrombin were generated per surface TF molecule for the 250-μm-long coating. A single layer of platelets (obtained with α IIb β 3 antagonism preventing continued platelet deposition) was largely sufficient for thrombin production. Also, the overall thrombin-generating potential of a 1000-μm-long coating became less efficient on a per μm 2 basis, likely due to distal boundary layer depletion of platelets. Overall, thrombin is robustly generated within clots by the extrinsic pathway followed by late-stage FXIa contributions, with fibrin localizing thrombin via its antithrombin-I activity as a potentially self-limiting hemostatic mechanism. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.
Rabiee, A R; Lean, I J
2013-01-01
The objective of this study was to assess the efficacy of internal teat sealant products containing bismuth subnitrate (Teatseal and Orbeseal; Pfizer Animal Health, West Ryde, Australia) when used alone, or in the presence of antibiotic dry cow therapy (ADCT), before or at drying off on the incidence of new intramammary infections (IMI), clinical mastitis, and milk somatic cell count (SCC) during lactation. The literature search identified 18 English-language publications on the use of Teatseal in dairy cattle. A total of 12 studies with 17 subtrials or comparisons including 13 positive control subtrials (internal teat sealant and ADCT vs. ADCT) and 4 negative control subtrials (internal teat sealant vs. untreated) examining IMI were included in the analysis. Internal teat sealants, alone or in the presence of ADCT, reduced the risk of acquiring new IMI after calving by 25% [risk ratio (RR)=0.75; 95% confidence interval (CI): 0.67 to 0.83]. Internal teat sealants reduced the risk of IMI by 73% compared with untreated cows (RR=0.27; 95% CI: 0.13 to 0.55). The results of both meta-analyses of IMI, with positive and negative controls, were heterogeneous [I(2) (a statistic that describes the proportion of total variation in study effect estimates that is due to heterogeneity)=65.4 and 92.1%]. No farm or cow factors studied significantly contributed to the heterogeneity of the results. A total of 16 studies (21 subtrials), including 14 positive control subtrials and 7 negative control subtrials, examining clinical mastitis were included in the analysis. Internal teat sealants alone and in the presence of ADCT reduced the risk of clinical mastitis after calving in lactating cows by 29% (RR=0.71; 95% CI: 0.62 to 0.82), and 48% (RR=0.52; 95% CI: 0.37 to 0.75), respectively. The results of the meta-analysis on clinical mastitis with positive controls were homogeneous (I(2)=33.6%), whereas the results of studies with negative controls were heterogeneous (I(2)=60.4%). No farm or cow factors studied that had sufficient data to evaluate significantly contributed to the heterogeneity of the results. The estimated linear score (LS) of milk SCC after calving in published studies (n=3) and for studies that provided raw data (n=2), was significantly lower for cattle treated with internal teat sealants and ADCT in 3 studies than for cattle treated with internal teat sealants only. The estimated LS of pooled raw data of 3 studies from 32 herds showed that the LS of cows treated with internal teat sealant and ADCT was not significantly different than those treated with ADCT only. This study found that the application of internal teat sealants in the presence of ADCT or the use of internal teat sealants alone at dry off significantly reduced the incidence of IMI and clinical mastitis in lactating dairy cows compared with respective control groups. Further studies are needed to investigate the effect of internal teat sealants on postpartum milk SCC in lactating dairy cows. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Hatirli, Hüseyin; Yasa, Bilal; Yasa, Elif
2018-01-30
The aim of the study was to evaluate microleakage and the penetration-depths of different fissure-sealant materials applied with/without enameloplasty after cyclic aging. One-hundred-sixty mandibular molars were divided into non-invasive and enameloplasty preparation groups and eight material subgroups, including: flowable composites (microhyrid, nanohybrid, and nanofilled), three resin-based (unfilled, filled, and highly-filled), a giomer-based, and a glass-ionomer-based fissure sealant. Specimens were subjected to two-year cyclic chewing and brushing simulation. After 5% basic-fuchsin dye penetration, specimens were sectioned and scored under stereomicroscope. Kruskal-Wallis statistical data showed that preparation type significantly affected the penetration of all tested materials (p<0.05), but not significantly affected microleakage (p>0.05). Flowable composites showed the best and the glass-ionomer-based sealant showed the worst penetration and microleakage. Slight preparation of fissures is not important in microleakage. However, enameloplasty significantly enhanced the depth of penetration of the sealants. Flowable composites offer promising results at the fissure sealing.
Recalcitrant Epithelial Ingrowth After SMILE Treated With a Hydrogel Ocular Sealant.
Thulasi, Praneetha; Kim, Sang Woo; Shetty, Rohit; Randleman, J Bradley
2015-12-01
To report a case of recalcitrant epithelial ingrowth after small incision lenticule extraction (SMILE) treated successfully with a novel hydrogel ocular sealant. Case report and literature review. A 32-year-old man who underwent small incision lenticule extraction (SMILE) complicated by difficult lenticule extraction developed visually significant epithelial ingrowth. He then underwent two flap lifts and epithelial scrapings and flap edge suturing with recurrence of epithelial ingrowth despite these interventions. He subsequently underwent repeat scraping, followed by hydrogel ocular sealant placement (ReSure Sealant; Ocular Therapeutix, Inc., Bedford, MA), which prevented recurrence of epithelial ingrowth and reduced corneal haze. The patient was also found to have undiagnosed diabetes, suggesting that just as in LASIK, diabetes may be a risk factor for epithelial ingrowth after SMILE. Interface epithelial ingrowth is a potential complication after SMILE and diabetes may be a risk factor for this complication. Hydrogel ocular sealant may be effective after SMILE to prevent epithelial ingrowth into the interface. Copyright 2015, SLACK Incorporated.
Evaluation of Solubility and Microleakage of Glass Carbomer Sealant.
Subramaniam, P; Girish Babu, K L; Jayasurya, S
2015-01-01
This study was carried out to evaluate and compare solubility and microleakage of the newly introduced moisture tolerant glass carbomer sealant. For evaluation of solubility, 20 specimens of glass carbomer and conventional glass ionomer were prepared and immersed in artificial saliva of pH 4 and 6 for seven days. The difference between initial and final weight was calculated. For evaluation of microleakage, glass carbomer was compared with a conventional resin sealant. 20 premolar teeth indicated for orthodontic extraction were collected and divided into two groups and the respective sealants were applied. It was subjected to thermocycling and then kept immersed in methylene blue for 24 hours. Dye penetration was scored. The glass carbomer specimens were less soluble than the conventional glass ionomer at both pH values. There was no significant difference in the microleakage. Being moisture resistant, glass carbomer can be used as an alternative fissure sealant material; especially in young children with partially erupted teeth and where obtaining moisture control is difficult.
Near-infrared imaging of demineralization under sealants
NASA Astrophysics Data System (ADS)
Tom, Henry; Simon, Jacob C.; Chan, Kenneth H.; Darling, Cynthia L.; Fried, Daniel
2014-07-01
Previous studies have shown that near-infrared (NIR) reflectance and transillumination imaging can be used to acquire high contrast images of early caries lesions and composite restorative materials. The aim of the study was to determine the optimum NIR wavelengths for imaging demineralized areas under dental sealants. Fifteen natural human premolars and molars with occlusal lesions were used in this in vitro study. Images before and after application of sealants were acquired using NIR reflectance and NIR transillumination at wavelengths of 1300, 1460, and 1500 to 1700 nm. Images were also acquired using polarization sensitive optical coherence tomography (OCT) for comparison. The highest contrast for NIR reflectance was at 1460 nm and 1500 to 1700 nm. These NIR wavelengths are coincident with higher water absorption. The clear Delton sealant investigated was not visible in either copolarization or cross-polarization OCT images. The wavelength region between 1500 and 1700 nm yielded the highest contrast of lesions under sealants for NIR reflectance measurements.
Near-infrared imaging of demineralization under sealants.
Tom, Henry; Simon, Jacob C; Chan, Kenneth H; Darling, Cynthia L; Fried, Daniel
2014-01-01
Previous studies have shown that near-infrared (NIR) reflectance and transillumination imaging can be used to acquire high contrast images of early caries lesions and composite restorative materials. The aim of the study was to determine the optimum NIR wavelengths for imaging demineralized areas under dental sealants. Fifteen natural human premolars and molars with occlusal lesions were used in this in vitro study. Images before and after application of sealants were acquired using NIR reflectance and NIR transillumination at wavelengths of 1300, 1460, and 1500 to 1700 nm. Images were also acquired using polarization sensitive optical coherence tomography (OCT) for comparison. The highest contrast for NIR reflectance was at 1460 nm and 1500 to 1700 nm. These NIR wavelengths are coincident with higher water absorption. The clear Delton sealant investigated was not visible in either copolarization or cross-polarization OCT images. The wavelength region between 1500 and 1700 nm yielded the highest contrast of lesions under sealants for NIR reflectance measurements.
Fibrin mechanical properties and their structural origins.
Litvinov, Rustem I; Weisel, John W
2017-07-01
Fibrin is a protein polymer that is essential for hemostasis and thrombosis, wound healing, and several other biological functions and pathological conditions that involve extracellular matrix. In addition to molecular and cellular interactions, fibrin mechanics has been recently shown to underlie clot behavior in the highly dynamic intra- and extravascular environments. Fibrin has both elastic and viscous properties. Perhaps the most remarkable rheological feature of the fibrin network is an extremely high elasticity and stability despite very low protein content. Another important mechanical property that is common to many filamentous protein polymers but not other polymers is stiffening occurring in response to shear, tension, or compression. New data has begun to provide a structural basis for the unique mechanical behavior of fibrin that originates from its complex multi-scale hierarchical structure. The mechanical behavior of the whole fibrin gel is governed largely by the properties of single fibers and their ensembles, including changes in fiber orientation, stretching, bending, and buckling. The properties of individual fibrin fibers are determined by the number and packing arrangements of double-stranded half-staggered protofibrils, which still remain poorly understood. It has also been proposed that forced unfolding of sub-molecular structures, including elongation of flexible and relatively unstructured portions of fibrin molecules, can contribute to fibrin deformations. In spite of a great increase in our knowledge of the structural mechanics of fibrin, much about the mechanisms of fibrin's biological functions remains unknown. Fibrin deformability is not only an essential part of the biomechanics of hemostasis and thrombosis, but also a rapidly developing field of bioengineering that uses fibrin as a versatile biomaterial with exceptional and tunable biochemical and mechanical properties. Copyright © 2016 Elsevier B.V. All rights reserved.
Elastic Behavior and Platelet Retraction in Low- and High-Density Fibrin Gels
Wufsus, Adam R.; Rana, Kuldeepsinh; Brown, Andrea; Dorgan, John R.; Liberatore, Matthew W.; Neeves, Keith B.
2015-01-01
Fibrin is a biopolymer that gives thrombi the mechanical strength to withstand the forces imparted on them by blood flow. Importantly, fibrin is highly extensible, but strain hardens at low deformation rates. The density of fibrin in clots, especially arterial clots, is higher than that in gels made at plasma concentrations of fibrinogen (3–10 mg/mL), where most rheology studies have been conducted. Our objective in this study was to measure and characterize the elastic regimes of low (3–10 mg/mL) and high (30–100 mg/mL) density fibrin gels using shear and extensional rheology. Confocal microscopy of the gels shows that fiber density increases with fibrinogen concentration. At low strains, fibrin gels act as thermal networks independent of fibrinogen concentration. Within the low-strain regime, one can predict the mesh size of fibrin gels by the elastic modulus using semiflexible polymer theory. Significantly, this provides a link between gel mechanics and interstitial fluid flow. At moderate strains, we find that low-density fibrin gels act as nonaffine mechanical networks and transition to affine mechanical networks with increasing strains within the moderate regime, whereas high-density fibrin gels only act as affine mechanical networks. At high strains, the backbone of individual fibrin fibers stretches for all fibrin gels. Platelets can retract low-density gels by >80% of their initial volumes, but retraction is attenuated in high-density fibrin gels and with decreasing platelet density. Taken together, these results show that the nature of fibrin deformation is a strong function of fibrin fiber density, which has ramifications for the growth, embolization, and lysis of thrombi. PMID:25564864
Contact allergy to epoxy (meth)acrylates.
Aalto-Korte, Kristiina; Jungewelter, Soile; Henriks-Eckerman, Maj-Len; Kuuliala, Outi; Jolanki, Riitta
2009-07-01
Contact allergy to epoxy (meth)acrylates, 2,2-bis[4-(2-hydroxy-3-methacryloxypropoxy) phenyl]propane (bis-GMA), 2,2-bis[4-(2-hydroxy-3-acryloxypropoxy)phenyl]-propane (bis-GA), 2,2-bis[4-(methacryl-oxyethoxy)phenyl] propane (bis-EMA), 2,2-bis[4-(methacryloxy)phenyl]-propane (bis-MA), and glycidyl methacrylate (GMA) is often manifested together with contact allergy to diglycidyl ether of bisphenol A (DGEBA) epoxy resin. To analyse patterns of concomitant allergic reactions to the five epoxy (meth)acrylates in relation to exposure. We reviewed the 1994-2008 patch test files at the Finnish Institute of Occupational Health (FIOH) for reactions to the five epoxy (meth)acrylates, and examined the patients' medical records for exposure. Twenty-four patients had an allergic reaction to at least one of the studied epoxy (meth)acrylates, but specific exposure was found only in five patients: two bis-GMA allergies from dental products, two bis-GA allergies from UV-curable printing inks, and one bis-GA allergy from an anaerobic glue. Only 25% of the patients were negative to DGEBA epoxy resin. The great majority of allergic patch test reactions to bis-GMA, bis-GA, GMA and bis-EMA were not associated with specific exposure, and cross-allergy to DGEBA epoxy resin remained a probable explanation. However, independent reactions to bis-GA indicated specific exposure. Anaerobic sealants may induce sensitization not only to aliphatic (meth)acrylates but also to aromatic bis-GA.
Marginal microleakage of triage sealant under different moisture contamination.
Peng, Yawen; Stark, Paul C; Rich, Alfred; Loo, Cheen Y
2011-01-01
Glass ionomer sealants (GISs) are promoted in pediatric dentistry for their moisture-friendly properties. This study's purpose was to investigate the marginal leakage of a glass ionomer sealant (Fuji Triage) under different moisture environments. Eighty extracted teeth were distributed into 4 groups: (1) control; (2) saliva contamination with 1-second air-thinning; (3) saliva contamination with 10 seconds of air-drying; and (4) saliva contamination with reconditioning. Sealants were placed after contamination. All extracted teeth underwent thermocycling followed by 1% methylene blue dye and distilled water wash. All extracted teeth were then sectioned buccolingually into 3 cross-sections and examined at 60X under a stereomicroscope. Microleakage was assessed using a dye penetration scoring system (score=0-3). Data were analyzed with Kruskal-Wallis and Mann-Whitney tests. The control group showed significantly lower marginal leakage than the other 3 groups (P<.02). There was no statistically significant difference among the 3 contaminated groups (P>.34). Fuji Triage sealant had the least marginal leakage under a moisture-controlled environment. When saliva was introduced during the application of the material, microleakage significantly increased. When contamination occurred, 1-second air-thinning of the saliva, 10-second air-drying of the saliva, or reconditioning before sealant application did not show a difference in decreasing microleakage.
Evaluation of microtensile bond strength of different fissure sealants to bovine enamel.
Sen Tunc, E; Bayrak, S; Tuloglu, N; Ertas, E
2012-03-01
The aim of this study was to evaluate the microtensile bond strength (μTBS) of a new fissure sealant and compare it with conventional sealants which are applied to enamel alone, and also with self-etch and etch-and-rinse adhesives. Enamel specimens were prepared and randomly distributed into three groups according to fissure sealant (Aegis, Helioseal F, Helioseal Clear). Each group was then subdivided according to adhesive system (Clearfil S3, Single Bond, no adhesive). A universal testing machine was used to measure μTBS, and data were analysed using one-way ANOVA and Tukey's tests. μTBS values for all Aegis subgroups were significantly lower than for comparable Helioseal F and Helioseal Clear subgroups (p < 0.05). No differences were observed in μTBS of Helioseal F and Helioseal Clear (p > 0.05). In the Helioseal Clear group, μTBS values for Single Bond were significantly higher than for Clearfil S3 (p < 0.05). However, no significant differences were found between the μTBS values of the adhesive subgroups in the Aegis or Helioseal F groups (p > 0.05). Sealant μTBS values may be affected by material content. The addition of an adhesive may improve μTBS values of sealant to enamel. © 2012 Australian Dental Association.
A Chitosan-Based Sinus Sealant for Reduction of Adhesion Formation in Rabbit and Sheep Models
Medina, Jennifer G.; Steinke, John W.; Das, Subinoy
2013-01-01
Objective Chronic sinusitis is the most prevalent chronic disease in the United States in adults aged 18 to 44 years, with approximately 250,000 operations performed annually. Although often successful, sinus surgery fails in greater than 15% of patients. Adhesion formation is a common complication and cause for subsequent revision surgery. Here, the authors evaluate a sprayable chitosan/starch-based sinus sealant and demonstrate its ability to reduce adhesion formation both in vitro and in 2 animal models. Study Design Randomized, controlled, animal trials. Setting Academic medical center (fibroblast experiments) and animal laboratories (sheep and rabbit studies). Subjects and Methods This sinus sealant was applied to human cultured fibroblasts obtained from surgically removed polyps to examine its ability to inhibit fibroblast migration and proliferation. The sinus sealant was applied to New Zealand White rabbits (n = 20) in an established cecal-sidewall abrasion model and to sheep (n = 10) in a sinus surgical adhesion model to examine its ability to reduce adhesion formation. Results This sinus sealant inhibited migration and proliferation of human cultured fibroblasts and reduced the total adhesion score from 4.9 to 0.3 for a total reduction of 94% (95th percentile confidence interval [CI], 78%, 100%; P < .001) in a well-established rabbit cecal-sidewall model commonly used for adhesion testing. Moreover, this sealant reduced adhesion formation from 80% to 10% for a total reduction of 70% (95th percentile CI, 57%, 93%; P = .003) in a sheep sinus adhesion surgical model. Conclusion This chitosan-based sealant demonstrates promise for reducing adhesion formation in sinus surgery. PMID:22492298
Technical manual for manufacturing autologous fibrin tissue adhesive.
Park, J J; Cintron, J R; Siedentop, K H; Orsay, C P; Pearl, R K; Nelson, R L; Abcarian, H
1999-10-01
The aim of this article is to provide a concise and simple technical manual for manufacturing autologous fibrin tissue adhesive derived from the precipitation of fibrinogen using a combination of ethanol and freezing for surgery. All materials and equipment needed to manufacture ethanol-based autologous fibrin tissue adhesive are listed. In addition, step-by-step instructions are provided to allow for easy and rapid fibrin adhesive production. Ethanol-based autologous fibrin tissue adhesive can be manufactured in under 60 minutes. Furthermore, at our institution the startup cost for manufacturing ethanol-based autologous fibrin tissue adhesive was under $2,500.00. Ethanol-based autologous fibrin tissue adhesive is a safe, reliable, and easily manufactured autologous fibrin tissue adhesive that can be made by a trained technician in any blood bank, pharmacy, or surgical laboratory.
Laven, R A; Balcomb, C C; Tulley, W T; Lawrence, K E
2014-07-01
The aim of this study was to evaluate, under farm conditions, the use of a teat sealant in addition to whole herd dry cow antibiotic therapy on the risk of clinical mastitis in dairy cattle at pasture, and to evaluate the impact of dry period length on that risk and the impact of the teat sealant on that risk. Dairy cows in three herds which used routine whole herd antibiotic therapy were randomly assigned to receive either treatment with an internal teat sealant (n=322) or no additional treatment (n=313) at drying-off between March and May 2010. All clinical mastitis cases during the dry period and to the end of the subsequent lactation were recorded by farm staff; factors affecting risk of clinical mastitis were then analysed using a Cox proportional hazards model. Median duration of the dry period was 112 days with >25% of cows having a dry period >130 days. The incidence risk of mastitis during lactation for cows treated with teat sealant was 9.9 (95% CI=6.9-13.7) cases per 100 cows compared with 17.9 (95% CI=13.8-22.6) cases per 100 cows for cows treated with antibiotic alone. The addition of a teat sealant to dry cow antibiotic therapy decreased the risk of clinical mastitis only in the first 33 days after calving (Hazard risk 0.24 (95% CI=0.12-0.48)). Length of dry period did not significantly affect the risk of clinical mastitis, or the effect of adding teat sealant to dry cow antibiotic therapy on the risk of clinical mastitis. In these herds where, based on the mastitis history, whole herd antibiotic therapy had been recommended, the use of a teat sealant significantly reduced the risk of clinical mastitis. This effect was limited to the first 33 days after calving; subsequently there was no significant effect of treatment. There was no effect of dry period length on risk of clinical mastitis, nor any significant interaction with treatment. Combination therapy with teat sealant and antibiotic was effective under New Zealand conditions in herds using whole herd antibiotic treatment at drying off. Teat sealant reduced risk of clinical mastitis in cattle with dry periods substantially longer than 100 days, and there was no evidence that this effect changed as dry period length increased.
NASA Astrophysics Data System (ADS)
Ghosh, Debaroti
Surface treatment using sealants as a mean of pavement preservation is an important tool for cost-effectively extending service life of pavement. Sealants have become an important tool for cost-effectively extending the service life pavements. Due to the combined negative effects of asphalt aging and thermal cracking, it is always more challenging to choose an appropriate preservation technique for pavements built in cold-regions. Asphalt aging and thermal cracking negatively affect pavements built in cold climates. Therefore, it is important to evaluate the effects of sealants in laboratory conditions before application in the field to ensure effective performance. However, preservation activities cannot effectively address major distresses, such as low-temperature cracking, that can occur when the pavement was built from the very beginning with less durable materials. Therefore, an essential requirement to mitigate low-temperature cracking of pavements for asphalt materials used in the construction of pavement built in cold- regions is ensuring proper fracture properties of the asphalt materials used in construction. This study has two parts. In the first part, a laboratory evaluation of the effects of adding bio-sealants to both asphalt binder and mixture is performed. The goal is to obtain relevant properties of treated asphalt materials to understand the mechanism by which sealants improve pavement performance. For asphalt binders, a dynamic shear rheometer and a bending beam rheometer were used to obtain rheological properties of treated and untreated asphalt binders. For asphalt mixtures, field cores from both untreated and treated sections were collected and thin beam specimens were prepared from the cores to compare the creep and strength properties of the field-treated and laboratory-treated mixture. It is observed that the oil-based sealants have a significant softening effect on the control binder compared to the water-based sealant and traditional emulsion. Oil-based sealants increased rutting and fatigue potential of the binder and helped the low-temperature cracking resistance. For asphalt mixtures, different trends are observed for the field samples compared to the laboratory prepared samples. Similar to binder results, significant differences are observed between the asphalt mixtures treated with oil-based and water-based sealants, respectively. Additional analyses were performed to better understand the sealant effects. Fourier transform infrared spectroscopy (FTIR) analysis showed that the sealant products could not be detected in mixture samples collected from the surface of the treated section. Semi-empirical Hirsch model was able to predict asphalt mixture creep stiffness from binder stiffness. The results of a distress survey of the test sections correlated well with the laboratory findings. In the second part, a news binder strength testing method is proposed with the goal to provide an effective tool for selecting asphalt binders that are crack resistant. A modified Bending Beam Rheometer (BBR) is used to perform three-point bending strength tests, at constant loading rate, on asphalt binder beams at low temperature. Based on the results, a protocol for selecting the most crack resistant material from binders with similar rheological properties is proposed.
Tumour imaging by the detection of fibrin clots in tumour stroma using an anti-fibrin Fab fragment.
Obonai, Toshifumi; Fuchigami, Hirobumi; Furuya, Fumiaki; Kozuka, Naoyuki; Yasunaga, Masahiro; Matsumura, Yasuhiro
2016-03-24
The diagnosis of early and aggressive types of cancer is important for providing effective cancer therapy. Cancer-induced fibrin clots exist only within lesions. Previously, we developed a monoclonal antibody (clone 102-10) that recognizes insoluble fibrin but not fibrinogen or soluble fibrin and confirmed that fibrin clots form continuously in various cancers. Here, we describe the development of a Fab fragment probe of clone 102-10 for tumour imaging. The distribution of 102-10 Fab was investigated in genetically engineered mice bearing pancreatic ductal adenocarcinoma (PDAC), and its effect on blood coagulation was examined. Immunohistochemical and ex vivo imaging revealed that 102-10 Fab was distributed selectively in fibrin clots in PDAC tumours 3 h after injection and that it disappeared from the body after 24 h. 102-10 Fab had no influence on blood coagulation or fibrinolysis. Tumour imaging using anti-fibrin Fab may provide a safe and effective method for the diagnosis of invasive cancers by detecting fibrin clots in tumour stroma.
Biodegradable-Polymer-Blend-Based Surgical Sealant with Body-Temperature-Mediated Adhesion.
Behrens, Adam M; Lee, Nora G; Casey, Brendan J; Srinivasan, Priya; Sikorski, Michael J; Daristotle, John L; Sandler, Anthony D; Kofinas, Peter
2015-12-22
The development of practical and efficient surgical sealants has the propensity to improve operational outcomes. A biodegradable polymer blend is fabricated as a nonwoven fiber mat in situ. After direct deposition onto the tissue of interest, the material transitions from a fiber mat to a film. This transition promotes polymer-substrate interfacial interactions leading to improved adhesion and surgical sealant performance. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
1983-12-01
maleic acid , adipic acid , azelaic acid and suberic acid . To ensure complete esterification during the exhaustive degradation reactions, an...spectroscopic techniques. Major components were shown to be sebacic acid and neopentyl glycol. The most significant difference between the two polyester...and acid equivalent weights of the prepolymers, their hydrolysis products and hydrolysed cured sealants were determined to assess extent of degradation
Comparison of the fibrin-binding activities in the N- and C-termini of fibronectin.
Rostagno, A A; Schwarzbauer, J E; Gold, L I
1999-03-01
Fibronectin (Fn) binds to fibrin in clots by covalent and non-covalent interactions. The N- and C-termini of Fn each contain one non-covalent fibrin-binding site, which are composed of type 1 (F1) structural repeats. We have previously localized the N-terminal site to the fourth and fifth F1 repeats (4F1.5F1). In the current studies, using proteolytic and recombinant proteins representing both the N- and C-terminal fibrin-binding regions, we localized and characterized the C-terminal fibrin-binding site, compared the relative fibrin-binding activities of both sites and determined the contribution of each site to the fibrin-binding activity of intact Fn. By fibrin-affinity chromatography, a protein composed of the 10F1 repeat through to the C-terminus of Fn (10F1-COOH), expressed in COS-1 cells, and 10F1-12F1, produced in Saccharomyces cerevisiae, displayed fibrin-binding activity. However, since 10F1 and 10F1.11F1 were not active, the presence of 12F1 is required for fibrin binding. A proteolytic fragment of 14.4 kDa, beginning 14 residues N-terminal to 10F1, was isolated from the fibrin-affinity matrix. Radio-iodinated 14.4 kDa fibrin-binding peptide/protein (FBP) demonstrated a dose-dependent and saturable binding to fibrin-coated wells that was both competitively inhibited and reversed by unlabelled 14.4 kDa FBP. Comparison of the fibrin-binding affinities of proteolytic FBPs from the N-terminus (25.9 kDa FBP), the C-terminus (14.4 kDa) and intact Fn by ELISA yielded estimated Kd values of 216, 18 and 2.1 nM, respectively. The higher fibrin-binding affinity of the N-terminus was substantiated by the ability of both a recombinant 4F1.5F1 and a monoclonal antibody (mAb) to this site to maximally inhibit biotinylated Fn binding to fibrin by 80%, and by blocking the 90% inhibitory activity of a polyclonal anti-Fn, by absorption with the 25.9 kDa FBP. We propose that whereas the N-terminal site appears to contribute to most of the binding activity of native Fn to fibrin, the specific binding of the C-terminal site may strengthen this interaction.
Comparison of the fibrin-binding activities in the N- and C-termini of fibronectin.
Rostagno, A A; Schwarzbauer, J E; Gold, L I
1999-01-01
Fibronectin (Fn) binds to fibrin in clots by covalent and non-covalent interactions. The N- and C-termini of Fn each contain one non-covalent fibrin-binding site, which are composed of type 1 (F1) structural repeats. We have previously localized the N-terminal site to the fourth and fifth F1 repeats (4F1.5F1). In the current studies, using proteolytic and recombinant proteins representing both the N- and C-terminal fibrin-binding regions, we localized and characterized the C-terminal fibrin-binding site, compared the relative fibrin-binding activities of both sites and determined the contribution of each site to the fibrin-binding activity of intact Fn. By fibrin-affinity chromatography, a protein composed of the 10F1 repeat through to the C-terminus of Fn (10F1-COOH), expressed in COS-1 cells, and 10F1-12F1, produced in Saccharomyces cerevisiae, displayed fibrin-binding activity. However, since 10F1 and 10F1.11F1 were not active, the presence of 12F1 is required for fibrin binding. A proteolytic fragment of 14.4 kDa, beginning 14 residues N-terminal to 10F1, was isolated from the fibrin-affinity matrix. Radio-iodinated 14.4 kDa fibrin-binding peptide/protein (FBP) demonstrated a dose-dependent and saturable binding to fibrin-coated wells that was both competitively inhibited and reversed by unlabelled 14.4 kDa FBP. Comparison of the fibrin-binding affinities of proteolytic FBPs from the N-terminus (25.9 kDa FBP), the C-terminus (14.4 kDa) and intact Fn by ELISA yielded estimated Kd values of 216, 18 and 2.1 nM, respectively. The higher fibrin-binding affinity of the N-terminus was substantiated by the ability of both a recombinant 4F1.5F1 and a monoclonal antibody (mAb) to this site to maximally inhibit biotinylated Fn binding to fibrin by 80%, and by blocking the 90% inhibitory activity of a polyclonal anti-Fn, by absorption with the 25.9 kDa FBP. We propose that whereas the N-terminal site appears to contribute to most of the binding activity of native Fn to fibrin, the specific binding of the C-terminal site may strengthen this interaction. PMID:10024513
Fibrin Glue Improves the Therapeutic Effect of MSCs by Sustaining Survival and Paracrine Function
Kim, Inok; Lee, Sung Koo; Yoon, Jung In; Kim, Da Eun
2013-01-01
Fibrin glue has been widely investigated as a cell delivery vehicle for improving the therapeutic effects of mesenchymal stem cells (MSCs). Implanted MSCs produce their therapeutic effects by secreting paracrine factors and by replacing damaged tissues after differentiation. While the influence of fibrin glue on the differentiation potential of MSCs has been well documented, its effect on paracrine function of MSCs is largely unknown. Herein we investigated the influence of fibrin glue on the paracrine effects of MSCs. MSCs were isolated from human adipose tissue. The effects of fibrin glue on survival, migration, secretion of growth factors, and immune suppression of MSCs were investigated in vitro. MSCs in fibrin glue survived and secreted growth factors such as the vascular endothelial growth factor (VEGF) and hepatocyte growth factor (HGF) over 14 days. VEGF and immune modulators, including the transforming growth factor (TGF)-β1 and prostaglandin E2, secreted from MSCs in fibrin glue significantly increased under inflammatory conditions. Thus, MSCs in fibrin glue effectively suppressed immune reactions. In addition, fibrin glue protected the MSCs from oxidative stress and prevented human dermal fibroblast death induced by exposure to extreme stress. In contrast, MSCs within fibrin glue hardly migrated. These results suggest that fibrin glue may sustain survival of implanted MSCs and their paracrine function. Our results provide a mechanistic data to allow further development of MSCs with fibrin glue as a clinical treatment. PMID:23701237
Enamel Surface with Pit and Fissure Sealant Containing 45S5 Bioactive Glass.
Yang, S-Y; Kwon, J-S; Kim, K-N; Kim, K-M
2016-05-01
Enamel demineralization adjacent to pit and fissure sealants leads to the formation of marginal caries, which can necessitate the replacement of existing sealants. Dental materials with bioactive glass, which releases ions that inhibit dental caries, have been studied. The purpose of this study was to evaluate the enamel surface adjacent to sealants containing 45S5 bioactive glass (BAG) under simulated microleakage between the material and the tooth in a cariogenic environment. Sealants containing 45S5BAG filler were prepared as follows: 0% 45S5BAG + 50.0% glass (BAG0 group), 12.5% 45S5BAG + 37.5% glass (BAG12.5 group), 25.0% 45S5BAG + 25.0% glass (BAG25.0 group), 37.5% 45S5BAG + 12.5% glass (BAG37.5 group), and 50.0% 45S5BAG + 0% glass (BAG50.0 group). A cured sealant disk was placed over a flat bovine enamel disk, separated by a 60-µm gap, and immersed in lactic acid solution (pH 4.0) at 37 °C for 15, 30, and 45 d. After the storage period, each enamel disk was separated from the cured sealant disk, and the enamel surface was examined with optical 3-dimensional surface profilometer, microhardness tester, and scanning electron microscopy. The results showed a significant increase in roughness and a decrease in microhardness of the enamel surface as the proportion of 45S5BAG decreased (P< 0.05). In the scanning electron microscopy images, enamel surfaces with BAG50.0 showed a smooth surface, similar to those in the control group with distilled water, even after prolonged acid storage. Additionally, an etched pattern was observed on the surface of the demineralized enamel with a decreasing proportion of 45S5BAG. Increasing the 45S5BAG filler contents of the sealants had a significant impact in preventing the demineralization of the enamel surface within microgaps between the material and the tooth when exposed to a cariogenic environment. Therefore, despite some marginal leakage, these novel sealants may be effective preventive dental materials for inhibiting secondary caries at the margins. © International & American Associations for Dental Research 2016.
Comparative evaluation of absorbable hemostats: advantages of fibrin-based sheets.
Krishnan, Lissy K; Mohanty, Mira; Umashankar, P R; Lal, Arthur Vijayan
2004-11-01
Bioactive hemostats and wound dressings consist of either inherently active materials or act as delivery vehicles which contain such materials. Fibrin is a natural hemostat and scaffold, guiding the direction of wound contraction and closure. In order to improve the ease of application of liquid fibrin glue, we have made a freeze-dried form of polymerized fibrin that supports hemostasis and wound healing. The bleeding from the middle ear artery of rabbits was found to be arrested instantaneously on application of fibrin sheets, even when the animal was heparinized systemically. As the fibrin sheet was found to be fragile, gelatin was incorporated to the sheet and thus the mechanical stability was improved without compromising the hemostatic effect. The efficacy of the fabricated fibrin and fibrin-gelatin sheets to seal traumatized rat liver was compared with commercially available hemostats, Abgel (cross-linked gelatin) and Surgicel (cross-linked cellulose). Tissue compatibility of all the hemostats was studied by analyzing the liver tissue 15 days after application. While the hemostatic effect was best with fibrin and fibrin-gelatin sheets, both Surgicel and Abgel were not capable of arresting the bleeding quickly. Gross analysis of tissue on the 15th day of application, visibly, Abgel was not only degraded but resulted in severe adhesions of internal organs and histologically capsule formation around the implant was evident. Though Surgicel was also seen as cream soft material on the site of application that joined two pieces of liver, there was no adhesion of other internal organs and histologically, immune reaction and foreign-body-type giant cells were present in large amounts. Fibrin was not found grossly on application site whereas fibrin-gelatin was seen as a small white spot. Granulation tissue formation and cell migration into the fibrin-based sheets were evident, and therefore, fibrin-based sheets are not only efficient hemostats but showed optimum degradation and wound healing.
A review of fibrin and fibrin composites for bone tissue engineering
Noori, Alireza; Ashrafi, Seyed Jamal; Vaez-Ghaemi, Roza; Hatamian-Zaremi, Ashraf; Webster, Thomas J
2017-01-01
Tissue engineering has emerged as a new treatment approach for bone repair and regeneration seeking to address limitations associated with current therapies, such as autologous bone grafting. While many bone tissue engineering approaches have traditionally focused on synthetic materials (such as polymers or hydrogels), there has been a lot of excitement surrounding the use of natural materials due to their biologically inspired properties. Fibrin is a natural scaffold formed following tissue injury that initiates hemostasis and provides the initial matrix useful for cell adhesion, migration, proliferation, and differentiation. Fibrin has captured the interest of bone tissue engineers due to its excellent biocompatibility, controllable biodegradability, and ability to deliver cells and biomolecules. Fibrin is particularly appealing because its precursors, fibrinogen, and thrombin, which can be derived from the patient’s own blood, enable the fabrication of completely autologous scaffolds. In this article, we highlight the unique properties of fibrin as a scaffolding material to treat bone defects. Moreover, we emphasize its role in bone tissue engineering nanocomposites where approaches further emulate the natural nanostructured features of bone when using fibrin and other nanomaterials. We also review the preparation methods of fibrin glue and then discuss a wide range of fibrin applications in bone tissue engineering. These include the delivery of cells and/or biomolecules to a defect site, distributing cells, and/or growth factors throughout other pre-formed scaffolds and enhancing the physical as well as biological properties of other biomaterials. Thoughts on the future direction of fibrin research for bone tissue engineering are also presented. In the future, the development of fibrin precursors as recombinant proteins will solve problems associated with using multiple or single-donor fibrin glue, and the combination of nanomaterials that allow for the incorporation of biomolecules with fibrin will significantly improve the efficacy of fibrin for numerous bone tissue engineering applications. PMID:28761338
A review of fibrin and fibrin composites for bone tissue engineering.
Noori, Alireza; Ashrafi, Seyed Jamal; Vaez-Ghaemi, Roza; Hatamian-Zaremi, Ashraf; Webster, Thomas J
2017-01-01
Tissue engineering has emerged as a new treatment approach for bone repair and regeneration seeking to address limitations associated with current therapies, such as autologous bone grafting. While many bone tissue engineering approaches have traditionally focused on synthetic materials (such as polymers or hydrogels), there has been a lot of excitement surrounding the use of natural materials due to their biologically inspired properties. Fibrin is a natural scaffold formed following tissue injury that initiates hemostasis and provides the initial matrix useful for cell adhesion, migration, proliferation, and differentiation. Fibrin has captured the interest of bone tissue engineers due to its excellent biocompatibility, controllable biodegradability, and ability to deliver cells and biomolecules. Fibrin is particularly appealing because its precursors, fibrinogen, and thrombin, which can be derived from the patient's own blood, enable the fabrication of completely autologous scaffolds. In this article, we highlight the unique properties of fibrin as a scaffolding material to treat bone defects. Moreover, we emphasize its role in bone tissue engineering nanocomposites where approaches further emulate the natural nanostructured features of bone when using fibrin and other nanomaterials. We also review the preparation methods of fibrin glue and then discuss a wide range of fibrin applications in bone tissue engineering. These include the delivery of cells and/or biomolecules to a defect site, distributing cells, and/or growth factors throughout other pre-formed scaffolds and enhancing the physical as well as biological properties of other biomaterials. Thoughts on the future direction of fibrin research for bone tissue engineering are also presented. In the future, the development of fibrin precursors as recombinant proteins will solve problems associated with using multiple or single-donor fibrin glue, and the combination of nanomaterials that allow for the incorporation of biomolecules with fibrin will significantly improve the efficacy of fibrin for numerous bone tissue engineering applications.
Kim, Beom Su; Shkembi, Feride; Lee, Jun
2017-01-01
Alendronate (ALN) is a bisphosphonate drug that is widely used for the treatment of osteoporosis. Furthermore, local delivery of ALN has the potential to improve the bone regeneration. This study was designed to investigate an ALN-containing fibrin (fibrin/ALN) gel and evaluate the effect of this gel on both in vitro cellular behavior using human mesenchymal stem cells (hMSCs) and in vivo bone regenerative capacity. Fibrin hydrogels were fabricated using various ALN concentrations (10 -7 -10 -4 M) with fibrin glue and the morphology, mechanical properties, and ALN release kinetics were characterized. Proliferation and osteogenic differentiation of and cytotoxicity in fibrin/ALN gel-embedded hMSCs were examined. In vivo bone formation was evaluated using a rabbit calvarial defect model. The fabricated fibrin/ALN gel was transparent with Young's modulus of ~13 kPa, and these properties were not affected by ALN concentration. The in vitro studies showed sustained release of ALN from the fibrin gel and revealed that hMSCs cultured in fibrin/ALN gel showed significantly increased proliferation and osteogenic differentiation. In addition, microcomputed tomography and histological analysis revealed that the newly formed bone was significantly enhanced by implantation of fibrin/ALN gel in a calvarial defect model. These results suggest that fibrin/ALN has the potential to improve bone regeneration.
Kim, Beom Su; Shkembi, Feride
2017-01-01
Alendronate (ALN) is a bisphosphonate drug that is widely used for the treatment of osteoporosis. Furthermore, local delivery of ALN has the potential to improve the bone regeneration. This study was designed to investigate an ALN-containing fibrin (fibrin/ALN) gel and evaluate the effect of this gel on both in vitro cellular behavior using human mesenchymal stem cells (hMSCs) and in vivo bone regenerative capacity. Fibrin hydrogels were fabricated using various ALN concentrations (10−7–10−4 M) with fibrin glue and the morphology, mechanical properties, and ALN release kinetics were characterized. Proliferation and osteogenic differentiation of and cytotoxicity in fibrin/ALN gel-embedded hMSCs were examined. In vivo bone formation was evaluated using a rabbit calvarial defect model. The fabricated fibrin/ALN gel was transparent with Young's modulus of ~13 kPa, and these properties were not affected by ALN concentration. The in vitro studies showed sustained release of ALN from the fibrin gel and revealed that hMSCs cultured in fibrin/ALN gel showed significantly increased proliferation and osteogenic differentiation. In addition, microcomputed tomography and histological analysis revealed that the newly formed bone was significantly enhanced by implantation of fibrin/ALN gel in a calvarial defect model. These results suggest that fibrin/ALN has the potential to improve bone regeneration. PMID:28210623
Hammad, Shaza M; Knösel, Michael
2016-11-01
White spot lesions (WSLs) are an undesirable side effect of fixed orthodontic appliance therapy and are reported to occur in 2-96 % of orthodontic patients. In this study, the efficacy of a new sealant to prevent WSLs during fixed orthodontic treatment was compared to a control group that did not receive sealant. For this 2-arm parallel-group randomized trial, 50 subjects aged 12-18 years (mean age 14.57 ± 2.04 years) were recruited from the orthodontics department at Mansoura University, Egypt. Eligibility criteria were no restorations, no active WSLs or caries, and adequate oral hygiene. Subjects were randomized in a 1:1 ratio to one of the two arms prior to undergoing fixed orthodontic treatment, namely a single application of SeLECT Defense™ sealant during the bracketing appointment or no sealant (control arm). Instructions and dentifrices for local home fluoridation regimen were identical in both groups. Oral hygiene was assessed using the Approximal Plaque Index (API) at specified time intervals. Dental photographs were taken for blinded WSLs assessment; inter- and intra-operator error were also calculated. Categorical data were tested using the χ 2 test, and a logistic regression model was adopted to detect associations between decalcification (WSLs), sealant application, and oral hygiene status. Only excellent or good oral hygiene were independent prognostic factors for preventing severe WSLs (p = 0.035). No significant effect on caries incidence was observed for the sealant. In combination with adequate oral hygiene SeLECT Defense™ helps to reduced the frequency of WSLs. However, the sealat showed no significant effect as sole preventive strategy.
1974-08-20
safeguards were employed in that a voltage monitoring strip chart recorder was employed during sealant placement to ensure continuous delivery of...adequate voltage to the ultraviolet light source (Nuva- Lite)* used for sealant polymerization. Also, a new air compressor** with suitable...ment effect in young Naval personnel. 2. The very low occlusal attack rate for untreated control teeth 3. Dirks, O. B., Houwink, B. and Kwant , G. W
Overview of CO2 Leakage Problems and Sealants for CO2 Leakage Remediation
NASA Astrophysics Data System (ADS)
Peng, Shudai
Excessive Carbon Dioxide (CO2) emission has become a serious issue and caused lots of environmental problems. Carbon Capture and Storage (CCS) program has been developed to reduce the CO2 content in the atmosphere. CO2 storage has been targeted mainly on depleted oil or gas reservoirs and deep saline aquifers. However, leakage could occur through wellbores, cap rocks, formation faults, and fractures during and after CO2 injection. To minimize the risk, different types of sealants have been investigated to prevent CO2 leaks. The aim of this thesis is to provide a comprehensive review of the materials which could be used as CO2 sealants. Based on the difference of materials components, this research has classified the sealants into seven types, including cements, geopolymers, foams, gel systems, resin systems, biofilm barriers, and nanoparticles. For each type of sealants, its chemical components, physical properties, stabilities, impact factors, applied environments, advantages and limitations were summarized. The most commonly used sealant for CO2 leakage control from wellbore is still cement, and the aluminate-calcium based cement has the best properties. It is very challenging to seal the fractures and faults, far from wellbore due to the difficulty to deliver plugging materials into the in-depth of a reservoir. The thermo-stability is also a great challenge for most materials and should be evaluated under supercritical CO2 condition.
Coal-tar based pavement sealant toxicity to freshwater macroinvertebrates.
Bryer, Pamela J; Scoggins, Mateo; McClintock, Nancy L
2010-05-01
Non-point-source pollution is a major source of ecological impairment in urban stream systems. Recent work suggests that coal-tar pavement sealants, used extensively to protect parking areas, may be contributing a large portion of the polycyclic aromatic hydrocarbon (PAH) loading seen in urban stream sediments. The hypothesis that dried coal-tar pavement sealant flake could alter the macroinvertebrate communities native to streams in Austin, TX was tested using a controlled outdoor laboratory type approach. The treatment groups were: control, low, medium, and high with total PAH concentrations (TPAH = sum of 16 EPA priority pollutant PAHs) of 0.1, 7.5, 18.4, & 300 mg/kg respectively. The low, medium, and high treatments were created via the addition of dried coal-tar pavement sealant to a sterile soil. At the start of the 24-day exposure, sediment from a minimally impacted local reference site containing a community of live sediment-dwelling benthic macroinvertebrates was added to each replicate. An exposure-dependent response was found for several stream health measures and for several individual taxa. There were community differences in abundance (P = 0.0004) and richness (P < 0.0001) between treatments in addition to specific taxa responses, displaying a clear negative relationship with the amount of coal-tar sealant flake. These results support the hypothesis that coal-tar pavement sealants contain bioavailable PAHs that may harm aquatic environments. Copyright 2009 Elsevier Ltd. All rights reserved.
Siman, Homayoun; Techy, Fernando
2016-02-01
Study Design Case report. Objective Incidental durotomy (IDT) is a common complication of spinal surgery. The use of collagen matrix graft along with hydrogel dural sealant is a common method of IDT repair. With this method, there have been several reported cases of detrimental dural sealant expansion in the literature. One case study reported an expansion rate greater than 300%; many report neurologic damage. This article reports the clinical course of two patients who developed postoperative transcutaneous drainage of a gel-like substance after the use of a dural sealant, which is a previously unreported complication. Methods The clinical course and treatment outcome of two patients is presented. Results Both patients experienced postoperative transcutaneous drainage of a gel-like substance at the surgical site. Case one began draining this substance on postoperative day 14. This patient required no further intervention, and the drainage ended after 3 mL of a gel-like substance was expressed from his incision while in the clinic. Case two began draining the gel on postoperative day 16. This patient underwent two washout procedures and resolution of the drainage. No infection was ever detected. Conclusions To our knowledge, our patients are the first reported cases of transcutaneous drainage of expanded dural sealant. It is important to take into consideration the unexpected expansion of a dural sealant when using it for the repair of IDT.
Siman, Homayoun; Techy, Fernando
2015-01-01
Study Design Case report. Objective Incidental durotomy (IDT) is a common complication of spinal surgery. The use of collagen matrix graft along with hydrogel dural sealant is a common method of IDT repair. With this method, there have been several reported cases of detrimental dural sealant expansion in the literature. One case study reported an expansion rate greater than 300%; many report neurologic damage. This article reports the clinical course of two patients who developed postoperative transcutaneous drainage of a gel-like substance after the use of a dural sealant, which is a previously unreported complication. Methods The clinical course and treatment outcome of two patients is presented. Results Both patients experienced postoperative transcutaneous drainage of a gel-like substance at the surgical site. Case one began draining this substance on postoperative day 14. This patient required no further intervention, and the drainage ended after 3 mL of a gel-like substance was expressed from his incision while in the clinic. Case two began draining the gel on postoperative day 16. This patient underwent two washout procedures and resolution of the drainage. No infection was ever detected. Conclusions To our knowledge, our patients are the first reported cases of transcutaneous drainage of expanded dural sealant. It is important to take into consideration the unexpected expansion of a dural sealant when using it for the repair of IDT. PMID:26835216
Biomaterials for Improved Wound Healing
2013-10-01
is silver sulphadiazine (SSD) [6-7]. SSD possesses a broad spectrum of activity against gram- positive and gram-negative bacteria as well as fungi [8... polyethylene glycol-based fibrin gel (PEGylated fibrin gel) induces vasculogenesis both in vitro and in vivo [20]. To exploit the inherent ability of fibrin as...Loaded Chitosan Microspheres Impregnated in Polyethylene Glycol Fibrin Gels (SSD-CSM-PEGylated fibrin gels) and Adipose Derived Stem Cells embedded
Thelwell, Craig; Williams, Stella C.; Silva, Marta M. C. G.; Szabó, László; Kolev, Krasimir
2011-01-01
Regulation of tissue-type plasminogen activator (tPA) depends on fibrin binding and fibrin structure. tPA structure/function relationships were investigated in fibrin formed by high or low thrombin concentrations to produce a fine mesh and small pores, or thick fibers and coarse structure, respectively. Kinetics studies were performed to investigate plasminogen activation and fibrinolysis in the 2 types of fibrin, using wild-type tPA (F-G-K1-K2-P, F and K2 binding), K1K1-tPA (F-G-K1-K1-P, F binding), and delF-tPA (G-K1-K2-P, K2 binding). There was a trend of enzyme potency of tPA > K1K1-tPA > delF-tPA, highlighting the importance of the finger domain in regulating activity, but the differences were less apparent in fine fibrin. Fine fibrin was a better surface for plasminogen activation but more resistant to lysis. Scanning electron and confocal microscopy using orange fluorescent fibrin with green fluorescent protein-labeled tPA variants showed that tPA was strongly associated with agglomerates in coarse but not in fine fibrin. In later lytic stages, delF-tPA-green fluorescent protein diffused more rapidly through fibrin in contrast to full-length tPA, highlighting the importance of finger domain-agglomerate interactions. Thus, the regulation of fibrinolysis depends on the starting nature of fibrin fibers and complex dynamic interaction between tPA and fibrin structures that vary over time. PMID:20966169
Coal-tar-based pavement sealants—a potent source of PAHs
Mahler, Barbara J.; Van Metre, Peter C.
2017-01-01
P avement sealants are applied to the asphalt pavement of many parking lots, driveways, and even playgrounds in North America (Figure 1), where, when first applied, they render the pavement glossy black and looking like new. Sealant products used commercially in the central, eastern, and northern United States typically are coal-tarbased, whereas those used in the western United States typically are asphalt-based. Although the products look similar, they are chemically different. Coal-tarbased pavement sealants typically are 25-35 percent (by weight) coal tar or coal-tar pitch, materials that are known human carcinogens and that contain high concentrations of polycyclic aromatic hydrocarbons (PAHs) and related chemicals (unless otherwise noted, all Figure 1. Pavement sealant is commonly used to seal parking lots, playgrounds, and driveways throughout the United States. Sealants used in the central, northern, eastern, and southern United States typically contain coal tar or coal-tar pitch, both of which are known human carcinogens. Photos by the U.S. Geological Survey. data in this article are from Mahler et al. 2012 and references therein).
Estrogenicity of resin-based composites and sealants used in dentistry.
Olea, N; Pulgar, R; Pérez, P; Olea-Serrano, F; Rivas, A; Novillo-Fertrell, A; Pedraza, V; Soto, A M; Sonnenschein, C
1996-01-01
We tested some resin-based composites used in dentistry for their estrogenic activity. A sealant based on bisphenol-A diglycidylether methacrylate (bis-GMA) increased cell yields, progesterone receptor expression, and pS2 secretion in human estrogen-target, serum-sensitive MCF7 breast cancer cells. Estrogenicity was due to bisphenol-A and bisphenol-A dimethacrylate, monomers found in the base paste of the dental sealant and identified by mass spectrometry. Samples of saliva from 18 subjects treated with 50 mg of a bis-GMA-based sealant applied on their molars were collected 1 hr before and after treatment. Bisphenol-A (range 90-931 micrograms) was identified only in saliva collected during a 1-hr period after treatment. The use of bis-GMA-based resins in dentistry, and particularly the use of sealants in children, appears to contribute to human exposure to xenoestrogens. Images Figure 1. A Figure 1. B Figure 2. Figure 3. A Figure 3. B Figure 4. A Figure 4. B Figure 5. A Figure 5. B Figure 6. A Figure 6. B Figure 7. A Figure 7. B Figure 8. Figure 9. Figure 10. PMID:8919768
Zhao, Wenxue; Han, Qianqian; Lin, Hang; Sun, Wenjie; Gao, Yuan; Zhao, Yannan; Wang, Bin; Wang, Xia; Chen, Bing; Xiao, Zhifeng; Dai, Jianwu
2009-05-01
Appropriate three-dimensional (3D) scaffolds and signal molecules could accelerate tissue regeneration and wound repair. In this work, we targeted human basic fibroblast growth factor (bFGF), a potent angiogenic factor, to a fibrin scaffold to improve therapeutic angiogenesis. We fused bFGF to the Kringle4 domain (K4), a fibrin-binding peptide from human plasminogen, to endow bFGF with specific fibrin-binding ability. The recombinant K4bFGF bound specifically to the fibrin scaffold so that K4bFGF was delivered in a site-specific manner, and the fibrin scaffold provided 3D support for cell migration and proliferation. Subcutaneous implantation of the fibrin scaffolds bound with K4bFGF but not with bFGF induced neovascularization. Immunohistochemical analysis showed significantly more proliferation cells in the fibrin scaffolds incorporated with K4bFGF than in those with bFGF. Moreover, the regenerative tissues were integrated well with the fibrin scaffolds, suggesting its good biocompatibility. In summary, targeted delivery of K4bFGF could potentially improve therapeutic angiogenesis.
In-situ AFM measurement of single fibrin fiber stiffness before and after addition of Factor XIII
NASA Astrophysics Data System (ADS)
Houser, John; O'Brien, E. Timothy; Lord, Susan T.; Superfine, Richard; Falvo, Michael R.
2008-10-01
Fibrin fibers are the main structural component of blood clots. Ligation of fibrin by native Factor XIII (FXIII) serves to fine tune the mechanical properties of the clot. Mechanical alteration is important because a clot must be stiff enough to resist forces from blood flow but compliant enough to prevent embolism (fracture). Cone and Plate measurements of fibrin gels, which represent the vast majority of mechanical measurements on fibrin, show that FXIII increases clot stiffness. More recently, measurements on individual fibrin fibers show that they exhibit remarkable extensibility, breaking at strains up to 300%. As of yet, the origin of this extensibility is not fully understood. The different responses of ligated and unligated fibrin fibers can give us clues as to it's mechanism of extension. We use a combined fluorescence/atomic force microscope to stretch individual, isolated, fibrin fibers and then compare force extension curves of the same fiber before and after addition of FXIII. We found up to a 3.5-fold increase in fiber stiffness after addition of FXIII. We also show stiffening of individual fibrin fibers after crosslinking by gluteraldehyde.
Tumour imaging by the detection of fibrin clots in tumour stroma using an anti-fibrin Fab fragment
Obonai, Toshifumi; Fuchigami, Hirobumi; Furuya, Fumiaki; Kozuka, Naoyuki; Yasunaga, Masahiro; Matsumura, Yasuhiro
2016-01-01
The diagnosis of early and aggressive types of cancer is important for providing effective cancer therapy. Cancer-induced fibrin clots exist only within lesions. Previously, we developed a monoclonal antibody (clone 102-10) that recognizes insoluble fibrin but not fibrinogen or soluble fibrin and confirmed that fibrin clots form continuously in various cancers. Here, we describe the development of a Fab fragment probe of clone 102-10 for tumour imaging. The distribution of 102-10 Fab was investigated in genetically engineered mice bearing pancreatic ductal adenocarcinoma (PDAC), and its effect on blood coagulation was examined. Immunohistochemical and ex vivo imaging revealed that 102-10 Fab was distributed selectively in fibrin clots in PDAC tumours 3 h after injection and that it disappeared from the body after 24 h. 102-10 Fab had no influence on blood coagulation or fibrinolysis. Tumour imaging using anti-fibrin Fab may provide a safe and effective method for the diagnosis of invasive cancers by detecting fibrin clots in tumour stroma. PMID:27009516
Bondalapati, Sailaja; Ambati, Balamurali
2016-01-01
To describe a novel technique for sutureless pterygium surgery using ReSure(®) tissue sealant. In this retrospective observational case series, we describe a modified procedure for pterygium excision followed by amniotic membrane transplant (AMT) adhered to the corneal and conjunctival defects using ReSure tissue sealant. Nine eyes of seven patients (age range: 28-80 years, 4 females and 3 males) underwent pterygium removal with AMT followed by adherence of tissue to the conjunctival edges with ReSure. No issues with transplant dislocation or failure and no intra- or postoperative complications were noted. No recurrences were noted during the follow-up period. ReSure may be considered as a potential sealant to adhere AMT to defective corneal and conjunctival tissues in sutureless pterygium surgery.
Sylman, Joanna L; Daalkhaijav, Uranbileg; Zhang, Ying; Gray, Elliot M; Farhang, Parsa A; Chu, Tiffany T; Zilberman-Rudenko, Jevgenia; Puy, Cristina; Tucker, Erik I; Smith, Stephanie A; Morrissey, James H; Walker, Travis W; Nan, Xiaolin L; Gruber, András; McCarty, Owen J T
2017-05-01
In the contact activation pathway of the coagulation, zymogen factor XII (FXII) is converted to FXIIa, which triggers activation of FXI leading to the activation of FIX and subsequent thrombin generation and fibrin formation. Feedback activation of FXI by thrombin has been shown to promote thrombin generation in a FXII-independent manner and FXIIa can bypass FXI to directly activate FX and prothrombin in the presence of highly negatively charged molecules, such as long-chain polyphosphates (LC polyP). We sought to determine whether activation of FXII or FXI differentially regulate the physical biology of fibrin formation. Fibrin formation was initiated with tissue factor, ellagic acid (EA), or LC polyP in the presence of inhibitors of FXI and FXII. Our data demonstrated that inhibition of FXI decreased the rate of fibrin formation and fiber network density, and increased the fibrin network strength and rate of fibrinolysis when gelation was initiated via the contact activation pathway with EA. FXII inhibition decreased the fibrin formation and fibrin density, and increased the fibrinolysis rate only when fibrin formation was initiated via the contact activation pathway with LC polyP. Overall, we demonstrate that inhibition of FXI and FXII distinctly alter the biophysical properties of fibrin.
Fate and Transport of Chemical Warfare Agents VX and HD ...
Report The intent of this investigation was to study the fate and transport of CWA applied to painted/sealed materials including the potential partitioning of CWA into permeable paints/sealants and subsequently into underlying porous materials. Based on the results obtained from this investigation, VX and sulfur mustard (HD) have the ability to permeate into paints and sealants, including in some cases the underlying porous materials. It is likely that other permeable materials besides paints and sealants may also show similar behavior.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wadhwa, Vibhor, E-mail: vwadhwa1@jhmi.edu; Leeper, William R., E-mail: rob.leeper@jhmi.edu; Tamrazi, Anobel, E-mail: atamraz1@jhmi.edu
2015-08-15
Biological sealants are being increasingly used in a variety of surgical specialties for their hemostatic and sealing capabilities. However, their use in interventional radiology has not been widely reported. The authors describe a case of duodenal perforation occurring after 15 years of gastric bypass surgery, in whom surgical diversion was unsuccessfully attempted and the leakage was successfully controlled using percutaneous administration of a combination of biological and organic sealants.
Ahmann, Katherine A.; Weinbaum, Justin S.; Johnson, Sandra L.
2010-01-01
Completely biological tissue replacements can be fabricated by entrapping cells in a molded fibrin gel. Over time, the fibrin is degraded and replaced with cell-produced extracellular matrix. However, the relationship between fibrin degradation and matrix deposition has not been elucidated. We developed techniques to quantify fibrin degradation products (FDP) and examine plasmin activity in the conditioned medium from fibrin-based constructs. Fibrin-based tissue constructs fabricated with vascular smooth muscle cells (vSMC) were cultured for 5 weeks in the presence of varied concentrations of the fibrinolysis inhibitor ɛ-aminocaproic acid and cellularity, and deposited collagen and elastin were measured weekly. These data revealed that increasing concentrations of ɛ-aminocaproic acid led to delayed and diminished FDP production, lower vSMC proliferation, and decreased collagen and elastin deposition. FDP were shown to have a direct biological effect on vSMC cultures and vSMC within the fibrin-based constructs. Supplementing construct cultures with 250 or 500 μg/mL FDP led to 30% higher collagen deposition than the untreated controls. FDP concentrations as high as 250 μg/mL were estimated to exist within the constructs, indicating that FDP generation during remodeling of the fibrin-based constructs exerted direct biological activity. These results help explain many of the positive outcomes reported with fibrin-based tissue constructs in the literature, as well as demonstrate the importance of regulating plasmin activity during their fabrication. PMID:20536358
Laparoscopic repair for perforated peptic ulcer disease.
Sanabria, Alvaro; Villegas, Maria Isabel; Morales Uribe, Carlos Hernando
2013-02-28
Perforated peptic ulcer is a common abdominal disease that is treated by surgery. The development of laparoscopic surgery has changed the way to treat such abdominal surgical emergencies. The results of some clinical trials suggest that laparoscopic surgery could be a better strategy than open surgery in the correction of perforated peptic ulcer but the evidence is not strongly in favour for or against this intervention. To measure the effect of laparoscopic surgical treatment versus open surgical treatment in patients with a diagnosis of perforated peptic ulcer in relation to abdominal septic complications, surgical wound infection, extra-abdominal complications, hospital length of stay and direct costs. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) on The Cochrane Library (2004, Issue 2), PubMed/MEDLINE (1966 to July 2004), EMBASE (1985 to November 2004) and LILACS (1988 to November 2004) as well as the reference lists of relevant articles. Searches in all databases were updated in December 2009 and January 2012. We did not confine our search to English language publications. Randomized clinical trials comparing laparoscopic surgery versus open surgery for the repair of perforated peptic ulcer using any mechanical method of closure (suture, omental patch or fibrin sealant). Primary outcome measures included proportion of septic and other abdominal complications (surgical site infection, suture leakage, intra-abdominal abscess, postoperative ileus) and extra-abdominal complications (pulmonary). Secondary outcomes included mortality, time to return to normal diet, time of nasogastric aspiration, hospital length-of-stay and costs. Outcomes were summarized by reporting odds ratios (ORs) and 95% confidence intervals (CIs), using the fixed-effect model. We included three randomized clinical trials of acceptable quality. We found no statistically significant differences between laparoscopic and open surgery in the proportion of abdominal septic complications (OR 0.66; 95% CI 0.30 to 1.47), pulmonary complications (OR 0.43; 95% CI 0.17 to 1.12) or number of septic abdominal complications (OR 0.60; 95% CI 0.32 to 1.15). Heterogeneity was significant for pulmonary complications and operating time. This review suggests that a decrease in septic abdominal complications may exist when laparoscopic surgery is used to correct perforated peptic ulcer. However, it is necessary to perform more randomized controlled trials with a greater number of patients to confirm such an assumption, guaranteeing a long learning curve for participating surgeons. With the information provided it could be said that laparoscopic surgery results are not clinically different from those of open surgery.
Starmans, Lucas W E; van Mourik, Tiemen; Rossin, Raffaella; Verel, Iris; Nicolay, Klaas; Grüll, Holger
2015-06-01
Fibrin deposition plays an important role in the formation of mature tumor stroma and provides a facilitating scaffold for tumor angiogenesis. This study investigates the potential of the (111)In-labeled fibrin-binding peptide EPep for SPECT imaging of intratumoral fibrin deposition. (111)In-EPep and negative control (111)In-NCEPep were synthesized and characterized in vitro. In vivo SPECT images and ex vivo biodistribution profiles and autoradiographs were obtained in a fibrin-rich BT-20 breast cancer mouse model. Furthermore, biodistribution profiles were obtained in the fibrin-poor MDA-MD-231 model. In vitro, (111)In-EPep displayed significantly more binding than (111)In-NCEPep toward human and mouse derived fibrin. SPECT/CT images displayed a marked SPECT signal in the tumor area for BT-20 tumor bearing mice injected with EPep but not for mice injected with NCEPep. Biodistribution profiles of BT-20 tumor bearing mice 3 h post-tracer injection showed significantly higher tumor uptake for EPep with respect to NCEPep (0.39 ± 0.14 and 0.11 ± 0.03% ID g(-1), respectively), whereas uptake in other organs was similar for EPep and NCEPep. Autoradiography of BT-20 tumor sections displayed a high signal for EPep which colocalized with intratumoral fibrin deposits. Histological evaluation of MDA-MB-231 tumor sections displayed no significant tumor stroma and only minute fibrin deposits. Biodistribution profiles in MDA-MB-231 tumor bearing mice 3 h post-injection showed EPep tumor uptake (0.14 ± 0.04% ID g(-1)) which was significantly lower with respect to EPep BT-20 tumor uptake, indicating fibrin-specificity of EPep tumoral uptake. In conclusion, this work demonstrates the potential of EPep SPECT imaging for visualization of tumoral fibrin deposition.
Fibrin-Enhanced Canonical Wnt Signaling Directs Plasminogen Expression in Cementoblasts
Rahman, Saeed Ur; Ryoo, Hyun-Mo
2017-01-01
Cementum is a mineralized layer on the tooth’s root surface and facilitates the biomechanical anchoring of fibrous connective tissues as a part of tooth-supportive complexes. Previously, we observed that OCCM30 cementoblasts cultured on fibrin matrices underwent apoptosis due to fibrin degradation through the expression of proteases. Here, we demonstrated that OCCM30 on fibrin matrices (OCCM30-fibrin) enhanced canonical Wnt signaling, which directed to plasminogen expression. The OCCM30-fibrin showed higher levels of Wnt3a expression, nuclear translocation of β-catenin, and T-cell factor (TCF) optimal motif (TOP) reporter activity than the cells on tissue culture dishes (OCCM30-TCD), indicating that the OCCM30-fibrin enhanced canonical Wnt/β-catenin signaling. Also, OCCM30-fibrin expressed biomineralization-associated markers at higher levels than OCCM30-TCD, of which levels were further increased with LiCl, a Wnt signaling activator. The OCCM30 cementoblasts simultaneously showed that high levels of plasminogen, a critical component of fibrinolysis, were expressed in the OCCM30-fibrin. Activation of canonical Wnt signaling with LiCl treatment or with forced lymphoid enhancer factor 1 (LEF1)-expression increased the expression of plasminogen. On the contrary, the inhibition of canonical Wnt signaling with siRNAs against Wnt3a or β-catenin abrogated fibrin-enhanced plasminogen expression. Furthermore, there are three conserved putative response elements for the LEF1/β-catenin complex in the plasminogen proximal promoter regions (−900 to +54). Site-directed mutations and chromatin immunoprecipitation indicated that canonical Wnt signaling directed plasminogen expression. Taken together, this study suggests that fibrin-based materials can modulate functional periodontal formations in controlling cementoblast differentiation and fibrin degradation. PMID:29120400
Park, Chan Ho; Oh, Joung-Hwan; Jung, Hong-Moon; Choi, Yoonnyoung; Rahman, Saeed Ur; Kim, Sungtae; Kim, Tae-Il; Shin, Hong-In; Lee, Yun-Sil; Yu, Frank H; Baek, Jeong-Hwa; Ryoo, Hyun-Mo; Woo, Kyung Mi
2017-10-01
Cementum formation on the exposed tooth-root surface is a critical process in periodontal regeneration. Although various therapeutic approaches have been developed, regeneration of integrated and functional periodontal complexes is still wanting. Here, we found that the OCCM30 cementoblasts cultured on fibrin matrix express substantial levels of matrix proteinases, leading to the degradation of fibrin and the apoptosis of OCCM30 cells, which was reversed upon treatment with a proteinase inhibitor, ε-aminocaproic acid (ACA). Based on these findings, ACA-releasing chitosan particles (ACP) were fabricated and ACP-incorporated fibrin (fibrin-ACP) promoted the differentiation of cementoblasts in vitro, as confirmed by bio-mineralization and expressions of molecules associated with mineralization. In a periodontal defect model of beagle dogs, fibrin-ACP resulted in substantial cementum formation on the exposed root dentin in vivo, compared to fibrin-only and enamel matrix derivative (EMD) which is used clinically for periodontal regeneration. Remarkably, the fibrin-ACP developed structural integrations of the cementum-periodontal ligament-bone complex by the Sharpey's fiber insertion. In addition, fibrin-ACP promoted alveolar bone regeneration through increased bone volume of tooth roof-of-furcation defects and root coverage. Therefore, fibrin-ACP can promote cementogenesis and osteogenesis by controlling biodegradability of fibrin, implicating the feasibility of its therapeutic use to improve periodontal regeneration. Cementum, the mineralized layer on root dentin surfaces, functions to anchor fibrous connective tissues on tooth-root surfaces with the collagenous Sharpey's fibers integration, of which are essential for periodontal functioning restoration in the complex. Through the cementum-responsible fiber insertions on tooth-root surfaces, PDLs transmit various mechanical responses to periodontal complexes against masticatory/occlusal stimulations to support teeth. In this study, periodontal tissue regeneration was enhanced by use of modified fibrin biomaterial which significantly promoted cementogenesis within the periodontal complex with structural integration by collagenous Sharpey's fiber insertions in vivo by controlling fibrin degradation and consequent cementoblast apoptosis. Furthermore, the modified fibrin could improve repair and regeneration of tooth roof-of-furcation defects, which has spatial curvatures and geometrical difficulties and hardly regenerates periodontal tissues. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
21 CFR 864.7320 - Fibrinogen/fibrin degradation products assay.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fibrinogen/fibrin degradation products assay. 864.7320 Section 864.7320 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN....7320 Fibrinogen/fibrin degradation products assay. (a) Identification. A fibrinogen/fibrin degradation...
Joint sealant materials for concrete pavement repairs.
DOT National Transportation Integrated Search
1991-01-01
This report on joint sealant materials for concrete pavement repairs is based on conversations with specialists from several states, the Federal Highway Administration, the Portland Cement Association, and the American Concrete Pavement Association, ...
21 CFR 872.3765 - Pit and fissure sealant and conditioner.
Code of Federal Regulations, 2012 CFR
2012-04-01
... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3765 Pit and fissure sealant and... depressions (faults in the enamel) in the biting surfaces of teeth to prevent cavities. (b) Classification...
21 CFR 872.3765 - Pit and fissure sealant and conditioner.
Code of Federal Regulations, 2013 CFR
2013-04-01
... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3765 Pit and fissure sealant and... depressions (faults in the enamel) in the biting surfaces of teeth to prevent cavities. (b) Classification...
Nagappan, N; Dhamodhar, M Dinesh; Nithin, M G; Kumar, E Senthil
2015-12-01
A study was aimed to assess the knowledge, value, opinion, and practice regarding the use of dental sealants among private dental practitioners in Chennai, Tamil Nadu, India. A self-administrated questionnaire were distributed to 192 private dental practitioners in Chennai, Tamil Nadu, India by using simple random sampling. A convenience sampling technique was employed. The questionnaire consisted of 28 items, which included information about knowledge, value, opinion, and practice regarding dental sealants. The questionnaire was obtained from the study by San Martin et al. 2013 and Kailash Asawa et al. 2014. Frequency distribution was tabulated. For frequency distribution strongly, strongly agree, and agree were combined as "agree" and strongly disagree and disagree were combined as "disagree." There were no changes in "neutral." Among the 196 study subjects 56.2% were males and 43.8% were females with their clinical experience of 52.1% for <5 years, 35.4% for 5-10 years, and 13.5% for >15 years. The mean scores for knowledge, value, opinion, and practice were 41.8 ± 3.7, 18.7 ± 2.8, 18.1 ± 1.4, and 12.9 ± 2.3, respectively. The results suggest that dental practitioners had satisfactory knowledge about pit and fissure sealant and had neutral attitudes about sealants being effective. Dental practitioners adequately used the pit and fissure sealants but they did not follow the standardized procedures and specific guidelines.
Choudhary, Prashant; Tandon, Shobha; Ganesh, M; Mehra, Anshul
2012-01-01
To evaluate the remineralization potential of Amorphous Calcium Phosphate (ACP) and Fluoride containing pit and Fissure Sealants using Scanning Electron Microscopy. Thirty maxillary first premolars were divided into three groups of ten each and were randomly selected for ACP containing (Aegis- Opaque White, Bosworth Co. Ltd.), Fluoride containing (Teethmate F1 Natural Clear, Kuraray Co. Ltd.), resin based (Concise- Opaque White, 3M ESPE Co. Ltd.) pit and fissure sealant applications. The Concise group served as a control. The teeth weresubjected to the pH-cycling regimen for a period of two weeks. After two weeks, the teeth were sectioned bucco-lingually into 4mm sections and were observed under Scanning Electron Microscope at 50X, 250X, 500X, 1000X and 1500X magnifications. The qualitative changes at the tooth surface and sealant interface were examined and presence of white zone at the interface was considered positive for remineralization. Both ACP containing (Aegis) and Fluoride containing (Teethmate F1) group showed white zone at the tooth surface-sealant interface. The resin based group (Concise) showed regular interface between the sealant and the tooth structure, but no clear cut white zone was observed. Both, Aegis and Teethmate F1 have the potential to remineralize. Release of Amorphous Calcium Phosphate molecules in Aegis group and formation of Fluoroapetite in Teethmate F1 group, were probably responsible for the remineralization.
In vitro comparison of two widely used surgical sealants for treating alveolar air leak.
Zhang, Ruoyu; Bures, Maximilian; Höffler, Klaus; Jonigk, Danny; Haverich, Axel; Krueger, Marcus
2014-12-01
Controversies surrounding the efficacy of sealants against alveolar air leak (AAL) are abundant in the literature. We sought to test the widely used sealants, TachoSil (Takeda Pharmaceutical Company Limited, Osaka, Japan) and BioGlue (CryoLife Europa Ltd., Surrey, United Kingdom) in an in vitro model. Materials and After creation of a focal superficial defect (40 × 25 mm) in swine lungs (n=40), AAL was assessed with increasing inspired tidal volume (TVi). Upon sealant application in a randomized order, AAL was assessed in the same way until sealant burst. At TVi =400, 500, 600, and 700 mL, BioGlue achieved sealing in 19, 19, 16, and 14 tests, while TachoSil sealed in 19, 14, 4, and no test, respectively. The maximally tolerated pressure of BioGlue was higher than TachoSil (40.3 ± 3.0 vs. 36.0 ± 4.9 cm H2O, p=0.003). Cohesive and adhesive failures were found in 10 and 1 tests of BioGlue, respectively, while all burst failures of TachoSil were adhesive. Concerning elasticity, TachoSil allowed more expansion of the covered defect than BioGlue (6.3 ± 3.9 vs. 1.4 ± 1.0 mm, p<0.001). The tested sealants demonstrated high sealing efficacy. While BioGlue was superior in resisting higher ventilation pressure, TachoSil possessed better elasticity. Georg Thieme Verlag KG Stuttgart · New York.
Hydrogel sealant versus sutures to prevent fluid egress after cataract surgery.
Masket, Samuel; Hovanesian, John A; Levenson, Jeffrey; Tyson, Farrell; Flynn, William; Endl, Michael; Majmudar, Parag A; Modi, Satish; Chu, Ralph; Raizman, Michael B; Lane, Stephen S; Kim, Terry
2014-12-01
To evaluate the effectiveness of a hydrogel sealant versus a suture in preventing fluid egress after wound leakage in cataract surgery. Twenty-four ophthalmic clinical practices in the United States. Prospective randomized parallel-arm controlled multicenter subject-masked study. Healthy patients having uneventful clear corneal incision (CCI) cataract surgery were eligible for the study. Spontaneous and provoked fluid egress from wounds was evaluated at the time of surgery using a calibrated force gauge. Eyes with leakage were randomized to receive a hydrogel sealant (Resure) or a nylon suture at the main incision site. Incision leakage was reevaluated 1, 3, 7, and 28 days postoperatively. Of 500 eyes, 488 had leakage at the time of cataract surgery. The leak was spontaneous in 244 cases (48.8%), and 488 (97.6%) of all incisions leaked with 1.0 ounce or less of applied force. After randomization, 12 (4.1%) of 295 eyes in the sealant group and 60 (34.1%) of 176 eyes in the suture group had wound leakage with provocation (P<.0001). The overall incidence of adverse ocular events was statistically significantly lower in the sealant group than in the suture group (P<.05). In this study, 97.6% of CCIs leaked after cataract surgery. The hydrogel sealant was safe and effective and better than a suture for the intraoperative management of CCIs with leakage as seen on Seidel testing and for the prevention of postoperative fluid egress. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Singh, Shamsher; Adlakha, Vivek; Babaji, Prashant; Chandna, Preetika; Thomas, Abi M; Chopra, Saroj
2013-10-01
Newer technologies and the development of pit and fissure sealants have shifted the treatment philosophy from 'drill and fill' to that of 'seal and heal'. The purpose of this in-vitro study was to evaluate the effects of bonding agents on the tensile bond strengths of two pit and fissure sealants by using invasive and non-invasive techniques. One hundred and twenty bicuspids were collected and teeth were divided into two groups: Group-I (Clinpro) and Group-II (Conseal f) with 60 teeth in each group. For evaluating tensile bond strengths, occlusal surfaces of all the teeth were flattened by reducing buccal and lingual cusps without disturbing fissures. Standardised polyvinyl tube was bonded to occlusal surfaces with respective materials. Sealants were applied, with or without bonding agents, in increments and they were light cured. Tensile bond strengths were determined by using Universal Testing Machine. Data were then statistically analysed by using Student t-test for comparison. A statistically significant difference was found in tensile bond strength in invasive with bonding agent group than in non-invasive with bonding agent group. This study revealed that invasive techniques increase the tensile bond strengths of sealants as compared to non- invasive techniques and that the use of a bonding agent as an intermediate layer between the tooth and fissure sealant is beneficial for increasing the bond strength.
Ulusoy, A T; Tunc, E S; Bayrak, Ş
2017-03-01
To evaluate the effects of two different resin coating materials on the clinical performance of a conventional glass ionomer sealant. Permanent first mandibular molars of 60 children aged 6-9 years were sealed with Fuji VII. In each child, G-Coat Plus coating agent was applied to molars on one side and Heliobond coating agent to molars on the opposite side of the mouth. Clinical evaluations were carried out at 1, 6, 12, 18 and 24 months after sealant and coating application. At 1, 6, 12, 18 and 24 months after sealant and coating application, total sealant retention rates were 88%, 40%, 19%, 15% and 9% for molars coated with G-Coat Plus, and 93%, 47%, 17%, 15% and 7% for those coated with Heliobond. The differences between the two coating agents were not statistically significant (p>0.05). No incidence of caries was observed in either group during the two-year evaluation period. Wilcoxon signed rank test was used to compare differences in retention rates and caries incidence by coating agent. Although retention rates of Fuji VII were relatively low and similar for both resin coating agents tested, dental caries were not observed in either group during the 24-month study period. In children with a high risk of caries and partially erupted molars, the use of a glass ionomer sealant with a resin-based coating agent should be encouraged.
White, C C; Tan, K T; O'Brien, E P; Hunston, D L; Chin, J W; Williams, R S
2011-02-01
The paper describes the development, implementation, and testing of two thermally driven outdoor exposure instruments. These devices are unique in their ability to impose field generated thermally induced strain on sealant specimens while monitoring their resulting load and displacement. The instruments combine a fixed wood and steel supporting frame with a moving polyvinyl chloride frame, and employ differences in the coefficients of thermal expansion between the supporting frame and moving frame to induce strain on the sealant specimens. Two different kinds of instruments have been fabricated, "winter/tension" and "winter/compression" designs. In the winter/tension design, the thermally induced dimensional change is directly transferred to the specimens; while in the winter/compression design, the samples are loaded in an opposite direction with the dimensional change. Both designs are instrumented to monitor load and displacement and are built so that the strain on the specimen does not exceed ±25% over the range of temperatures expected in Gaithersburg, MD. Additionally, a weather station is colocated with the device to record environmental conditions in 1 min intervals. This combination of weather information with mechanical property data enables a direct link between environmental conditions and the corresponding sealant response. The reliability and effectiveness of these instruments are demonstrated with a typical sealant material. The results show that the instruments work according to the design criteria and provide a meaningful quantitative platform to monitor the mechanical response of sealant exposed to outdoor weathering.
The Non-catalytic B Subunit of Coagulation Factor XIII Accelerates Fibrin Cross-linking*
Souri, Masayoshi; Osaki, Tsukasa; Ichinose, Akitada
2015-01-01
Covalent cross-linking of fibrin chains is required for stable blood clot formation, which is catalyzed by coagulation factor XIII (FXIII), a proenzyme of plasma transglutaminase consisting of catalytic A (FXIII-A) and non-catalytic B subunits (FXIII-B). Herein, we demonstrate that FXIII-B accelerates fibrin cross-linking. Depletion of FXIII-B from normal plasma supplemented with a physiological level of recombinant FXIII-A resulted in delayed fibrin cross-linking, reduced incorporation of FXIII-A into fibrin clots, and impaired activation peptide cleavage by thrombin; the addition of recombinant FXIII-B restored normal fibrin cross-linking, FXIII-A incorporation into fibrin clots, and activation peptide cleavage by thrombin. Immunoprecipitation with an anti-fibrinogen antibody revealed an interaction between the FXIII heterotetramer and fibrinogen mediated by FXIII-B and not FXIII-A. FXIII-B probably binds the γ-chain of fibrinogen with its D-domain, which is near the fibrin polymerization pockets, and dissociates from fibrin during or after cross-linking between γ-chains. Thus, FXIII-B plays important roles in the formation of a ternary complex between proenzyme FXIII, prosubstrate fibrinogen, and activator thrombin. Accordingly, congenital or acquired FXIII-B deficiency may result in increased bleeding tendency through impaired fibrin stabilization due to decreased FXIII-A activation by thrombin and secondary FXIII-A deficiency arising from enhanced circulatory clearance. PMID:25809477
Fibrin Formation, Structure and Properties
Weisel, John W.; Litvinov, Rustem I.
2017-01-01
Fibrinogen and fibrin are essential for hemostasis and are major factors in thrombosis, wound healing, and several other biological functions and pathological conditions. The X-ray crystallographic structure of major parts of fibrin(ogen), together with computational reconstructions of missing portions and numerous biochemical and biophysical studies, have provided a wealth of data to interpret molecular mechanisms of fibrin formation, its organization, and properties. On cleavage of fibrinopeptides by thrombin, fibrinogen is converted to fibrin monomers, which interact via knobs exposed by fibrinopeptide removal in the central region, with holes always exposed at the ends of the molecules. The resulting half-staggered, double-stranded oligomers lengthen into protofibrils, which aggregate laterally to make fibers, which then branch to yield a three-dimensional network. Much is now known about the structural origins of clot mechanical properties, including changes in fiber orientation, stretching and buckling, and forced unfolding of molecular domains. Studies of congenital fibrinogen variants and post-translational modifications have increased our understanding of the structure and functions of fibrin(ogen). The fibrinolytic system, with the zymogen plasminogen binding to fibrin together with tissue-type plasminogen activator to promote activation to the active proteolytic enzyme, plasmin, results in digestion of fibrin at specific lysine residues. In spite of a great increase in our knowledge of all these interconnected processes, much about the molecular mechanisms of the biological functions of fibrin(ogen) remains unknown, including some basic aspects of clotting, fibrinolysis, and molecular origins of fibrin mechanical properties. Even less is known concerning more complex (patho)physiological implications of fibrinogen and fibrin. PMID:28101869
Clinical study of cultured epithelial autografts in liquid suspension in severe burn patients.
Yim, Haejun; Yang, Hyeong Tae; Cho, Yong Suk; Seo, Cheong Hoon; Lee, Boung Chul; Ko, Jang Hyu; Kwak, In Suk; Kim, Dohern; Hur, Jun; Kim, Jong Hyun; Chun, Wook
2011-09-01
We address the clinical application of the suspension type cultured epithelial autografts (CEAs), Keraheal™ (MCTT, Seoul, Korea), along with the effects, application method, merits and demerits thereof. From February 2007 to June 2010, 29 burn patients with extensive burns, participated in the suspension type of CEA clinical test. A widely meshed autograft (1:4-6 ratio) was applied to the wound bed and the suspension type CEA was sprayed with a Tissomat cell sprayer, followed by a Tissucol spray, a fibrin sealant. The patients' (men/women=26/3) median (interquartile ranges) age was 42 (30-49) years old, the burned TBSA was 55 (44-60) %, and the full thickness burn area was 40 (30-46.5) %. The area of Keraheal™ applied was 800 (400-1200) cm(2). The take rate was 96 (90.5-99) % and 100 (98.5-100) % at 2 and 4 weeks after treatment with Keraheal™, respectively. The Vancouver burn scar scale was 5 (4-6.5), 4 (3-6), and 3 (2-4) at 8, 12 and 24 weeks after the Keraheal™ application. Widely meshed autograft must be applied in massive burns but it's take rate is greatly reduced. The CEAs enhance the take rate of a wide meshed autograft in massive burns and allow for grafting wide meshed autograft together with acellular dermal matrix in some cases. Copyright © 2011 Elsevier Ltd and ISBI. All rights reserved.
Srinivasan, Sathish; Danjoux, Jean-Pierre
2018-01-01
The number of laser in situ keratomileusis (LASIK) procedures is continuing to rise. Since its first application for correcting simple refractive errors over 25 years ago, the role of LASIK has extended to treat other conditions, including postkeratoplasty astigmatism/ametropia, postcataract surgery refractive error and presbyopia, among others. The long-term effectiveness, predictability and safety have been well established by many large studies. However, due to the creation of a potential interface between the flap and the underlying stroma, interface complications such as infectious keratitis, diffuse lamellar keratitis and epithelial ingrowth may occur. Post-LASIK epithelial ingrowth (PLEI) is an uncommon complication that usually arises during the early postoperative period. The reported incidence of PLEI ranged from 0%–3.9% in primary treatment to 10%–20% in retreatment cases. It can cause a wide spectrum of clinical presentations, ranging from asymptomatic interface changes to severe visual impairment and flap melt requiring keratoplasty. PLEI can usually be treated with mechanical debridement of the affected interface; however, additional interventions, such as alcohol, mitomycin C, fibrin glue, ocular hydrogel sealant, neodymium:yttriumaluminum garnet laser and amniotic membrane graft, may be required for recurrent or refractory cases. The aims of this review are to determine the prevalence and risk factors of PLEI; to describe its pathogenesis and clinical features and to summarise the therapeutic armamentarium and the visual outcome of PLEI. PMID:29657982
Ting, Darren Shu Jeng; Srinivasan, Sathish; Danjoux, Jean-Pierre
2018-01-01
The number of laser in situ keratomileusis (LASIK) procedures is continuing to rise. Since its first application for correcting simple refractive errors over 25 years ago, the role of LASIK has extended to treat other conditions, including postkeratoplasty astigmatism/ametropia, postcataract surgery refractive error and presbyopia, among others. The long-term effectiveness, predictability and safety have been well established by many large studies. However, due to the creation of a potential interface between the flap and the underlying stroma, interface complications such as infectious keratitis, diffuse lamellar keratitis and epithelial ingrowth may occur. Post-LASIK epithelial ingrowth (PLEI) is an uncommon complication that usually arises during the early postoperative period. The reported incidence of PLEI ranged from 0%-3.9% in primary treatment to 10%-20% in retreatment cases. It can cause a wide spectrum of clinical presentations, ranging from asymptomatic interface changes to severe visual impairment and flap melt requiring keratoplasty. PLEI can usually be treated with mechanical debridement of the affected interface; however, additional interventions, such as alcohol, mitomycin C, fibrin glue, ocular hydrogel sealant, neodymium:yttriumaluminum garnet laser and amniotic membrane graft, may be required for recurrent or refractory cases. The aims of this review are to determine the prevalence and risk factors of PLEI; to describe its pathogenesis and clinical features and to summarise the therapeutic armamentarium and the visual outcome of PLEI.
Technical factors associated with anastomotic leak after Roux-en-Y gastric bypass.
Smith, Mark D; Adeniji, Abidemi; Wahed, Abdus S; Patterson, Emma; Chapman, William; Courcoulas, Anita P; Dakin, Gregory; Flum, David; McCloskey, Carol; Mitchell, James E; Pomp, Alfons; Staten, Myrlene; Wolfe, Bruce
2015-01-01
Anastomotic leak is one of the most serious complications after Roux-en-Y gastric bypass (RYGB). Our objective was to examine the relationship between technical factors and incidence of clinically relevant anastomotic leak after RYGB in longitudinal assessment of bariatric surgery (LABS). The setting of the study was 11 bariatric centers in the United States, university, and private practice. Patient characteristics, technical factors of surgery, and postoperative outcomes were assessed by trained researchers using standardized protocols. Correlation of surgical factors of patients undergoing RYGB (n = 4444) with the incidence of postoperative anastomotic leak was assessed by univariate χ(2) analysis. Forty-four participants (1.0%, 95% CI .7%-1.3%) experienced a clinically relevant anastomotic leak. Of these, 39 (89%) underwent abdominal reoperation and 3 (7%) died. Technical factors associated with anastomotic leak were open surgery (P<.0001), revision surgery (P<.0001), and use of an abdominal drain (P = .02). Provocative leak testing, method of gastrojejunostomy, and use of fibrin sealant were not associated with anastomotic leak. Anastomotic leak after RYGB was rare (1.0%). Most cases required reintervention; however, the majority (93%) recovered from this event. Open surgery, revision surgery, and routine drain placement were associated with increased leak rate. Some of these findings may be due to differences in preoperative patient risk. Copyright © 2015 American Society for Metabolic and Bariatric Surgery. All rights reserved.
Bidault, Laurent; Deneufchatel, Marie; Vancaeyzeele, Cédric; Fichet, Odile; Larreta-Garde, Véronique
2013-11-11
A fibrin hydrogel at physiological concentration (5 mg/mL) was associated with polyvinyl alcohol (PVA) inside an interpenetrating polymer networks (IPN) architecture. Previously, PVA has been modified with methacrylate functions in order to cross-link it by free-radical polymerization. The fibrin network was synthesized by the enzymatic hydrolysis of fibrinogen by thrombin. The resulting self-supported materials simultaneously exhibit the properties of the fibrin hydrogel and those of the synthetic polymer network. Their storage modulus is 50-fold higher than that of the fibrin hydrogel and they are completely rehydratable. These materials are noncytotoxic toward human fibroblast and the fibrin present on the surface of PVAm-based IPNs favors cell development.
1993-10-01
sealant was determined by noting the type and number of defects each sealant incurred. Figure 4 provides a sample evaluation sheet used dur- ing the field...was conducted by visually inspect- ing the mater~al for defects . If any defects were noted, the type of defect was described and the quant~ty of that... defect was measured. The quantity of the defect was dividted by the total quantity of sealant and the result reported as percent defect . Adhesion and
The effect of fibrin on cultured vascular endothelial cells.
Kadish, J L; Butterfield, C E; Folkman, J
1979-01-01
The normal cobblestone monolayer architecture of cultured vascular endothelium becomes rapidly disorganized after contact of the cell layer with a fibrin clot. The cells of a confluent endothelial monolayer separate into individual migratory cells in 4--6 hr after contact with fibrin. The effect is reversible in that removal of the fibrin clot results in resumption of the normal morphology within about 2 hr. No other cell type tested exhibits the same change in organization when exposed to fibrin. A similar morphological change in endothelium does occur after the cell layer is overlaid with a collagen fibril gel but a gel of methylcellulose has no effect. It is proposed that the change in behavior of endothelial cells in response to contact with fibrin may represent a cellular component of fibrinolysis. The implications of this finding for the pathophysiology of disease states involving intravascular fibrin deposition are discussed.
Circulating Microparticles Alter Formation, Structure, and Properties of Fibrin Clots.
Zubairova, Laily D; Nabiullina, Roza M; Nagaswami, Chandrasekaran; Zuev, Yuriy F; Mustafin, Ilshat G; Litvinov, Rustem I; Weisel, John W
2015-12-04
Despite the importance of circulating microparticles in haemostasis and thrombosis, there is limited evidence for potential causative effects of naturally produced cell-derived microparticles on fibrin clot formation and its properties. We studied the significance of blood microparticles for fibrin formation, structure, and susceptibility to fibrinolysis by removing them from platelet-free plasma using filtration. Clots made in platelet-free and microparticle-depleted plasma samples from the same healthy donors were analyzed in parallel. Microparticles accelerate fibrin polymerisation and support formation of more compact clots that resist internal and external fibrinolysis. These variations correlate with faster thrombin generation, suggesting thrombin-mediated kinetic effects of microparticles on fibrin formation, structure, and properties. In addition, clots formed in the presence of microparticles, unlike clots from the microparticle-depleted plasma, contain 0.1-0.5-μm size granular and CD61-positive material on fibres, suggesting that platelet-derived microparticles attach to fibrin. Therefore, the blood of healthy individuals contains functional microparticles at the levels that have a procoagulant potential. They affect the structure and stability of fibrin clots indirectly through acceleration of thrombin generation and through direct physical incorporation into the fibrin network. Both mechanisms underlie a potential role of microparticles in haemostasis and thrombosis as modulators of fibrin formation, structure, and resistance to fibrinolysis.
Circulating Microparticles Alter Formation, Structure, and Properties of Fibrin Clots
Zubairova, Laily D.; Nabiullina, Roza M.; Nagaswami, Chandrasekaran; Zuev, Yuriy F.; Mustafin, Ilshat G.; Litvinov, Rustem I.; Weisel, John W.
2015-01-01
Despite the importance of circulating microparticles in haemostasis and thrombosis, there is limited evidence for potential causative effects of naturally produced cell-derived microparticles on fibrin clot formation and its properties. We studied the significance of blood microparticles for fibrin formation, structure, and susceptibility to fibrinolysis by removing them from platelet-free plasma using filtration. Clots made in platelet-free and microparticle-depleted plasma samples from the same healthy donors were analyzed in parallel. Microparticles accelerate fibrin polymerisation and support formation of more compact clots that resist internal and external fibrinolysis. These variations correlate with faster thrombin generation, suggesting thrombin-mediated kinetic effects of microparticles on fibrin formation, structure, and properties. In addition, clots formed in the presence of microparticles, unlike clots from the microparticle-depleted plasma, contain 0.1–0.5-μm size granular and CD61-positive material on fibres, suggesting that platelet-derived microparticles attach to fibrin. Therefore, the blood of healthy individuals contains functional microparticles at the levels that have a procoagulant potential. They affect the structure and stability of fibrin clots indirectly through acceleration of thrombin generation and through direct physical incorporation into the fibrin network. Both mechanisms underlie a potential role of microparticles in haemostasis and thrombosis as modulators of fibrin formation, structure, and resistance to fibrinolysis. PMID:26635081
Houser, John R; Hudson, Nathan E; Ping, Lifang; O'Brien, E Timothy; Superfine, Richard; Lord, Susan T; Falvo, Michael R
2010-11-03
Fibrin fibers form the structural scaffold of blood clots and perform the mechanical task of stemming blood flow. Several decades of investigation of fibrin fiber networks using macroscopic techniques have revealed remarkable mechanical properties. More recently, the microscopic origins of fibrin's mechanics have been probed through direct measurements on single fibrin fibers and individual fibrinogen molecules. Using a nanomanipulation system, we investigated the mechanical properties of individual fibrin fibers. The fibers were stretched with the atomic force microscope, and stress-versus-strain data was collected for fibers formed with and without ligation by the activated transglutaminase factor XIII (FXIIIa). We observed that ligation with FXIIIa nearly doubled the stiffness of the fibers. The stress-versus-strain behavior indicates that fibrin fibers exhibit properties similar to other elastomeric biopolymers. We propose a mechanical model that fits our observed force extension data, is consistent with the results of the ligation data, and suggests that the large observed extensibility in fibrin fibers is mediated by the natively unfolded regions of the molecule. Although some models attribute fibrin's force-versus-extension behavior to unfolding of structured regions within the monomer, our analysis argues that these models are inconsistent with the measured extensibility and elastic modulus. Copyright © 2010 Biophysical Society. Published by Elsevier Inc. All rights reserved.
PAH volatilization following application of coal-tar-based pavement sealant
Van Metre, Peter C.; Majewski, Michael S.; Mahler, Barbara J.; Foreman, William T.; Braun, Christopher L.; Wilson, Jennifer T.; Burbank, Teresa L.
2012-01-01
Coal-tar-based pavement sealants, a major source of PAHs to urban water bodies, have recently been identified as a source of volatile PAHs to the atmosphere. We tracked the volatilization of PAHs for 1 year after application of a coal-tar-based pavement sealant by measuring gas-phase PAH concentrations above the pavement surface and solid-phase PAH concentrations in sealant scraped from the surface. Gas-phase concentrations at two heights (0.03 and 1.28 m) and wind speed were used to estimate volatilization flux. The sum of the concentrations of eight frequently detected PAHs (ΣPAH8) in the 0.03-m sample 1.6 h after application (297,000 ng m-3) was about 5000 times greater than that previously reported for the same height above unsealed parking lots (66 ng m-3). Flux at 1.6 h after application was estimated at 45,000 μg m-2 h-1 and decreased rapidly during the 45 days after application to 160 μg m-2 h-1. Loss of PAHs from the adhered sealant also was rapid, with about a 50% decrease in solid-phase ΣPAH8 concentration over the 45 days after application. There was general agreement, given the uncertainties, in the estimated mass of ΣPAH8 lost to the atmosphere on the basis of air sampling (2–3 g m-2) and adhered sealant sampling (6 g m-2) during the first 16 days after application, translating to a loss to the atmosphere of one-quarter to one-half of the PAHs in the sealcoat product. Combining the estimated mass of ΣPAH8 released to the atmosphere with a national-use estimate of coal-tar-based sealant suggests that PAH emissions from new coal-tar-based sealcoat applications each year (~1000 Mg) are larger than annual vehicle emissions of PAHs for the United States.
SAZONOVA, I. Y.; MCNAMEE, R. A.; HOUNG, A. K.; KING, S. M.; HEDSTROM, L.; REED, G. L.
2013-01-01
Summary Background: Given the worldwide epidemic of cardiovascular diseases, a more effective means of dissolving thrombi that cause heart attacks, could markedly reduce death, disability and healthcare costs. Plasminogen activators (PAs) such as streptokinase (SK) and tissue plasminogen activator (TPA) are currently used to dissolve fibrin thrombi. SK is cheaper and more widely available, but it appears less effective because it lacks TPA’s fibrin-targeted properties that focus plasminogen activation on the fibrin surface. Objective: We examined whether re-programming SK’s mechanism of action would create PAs with greater fibrin-targeting and potency than TPA. Methods and Results: When fibrinogen consumption was measured in human plasma, reprogrammed molecules SKΔ1 and SKΔ59 were 5-fold and > 119-fold more fibrin-dependent than SK (P < 0.0001), and 2-fold and > 50-fold more fibrin-dependent than TPA (P < 0.001). The marked fibrin-targeting of SKΔ59 was due to the fact that: (i) it did not generate plasmin in plasma, (ii) it was rapidly inhibited by α2-antiplasmin, and (iii) it only processed fibrin-bound plasminogen. To assess the fibrin-targeting and therapeutic potential of these PAs in vivo, a novel ‘humanized’ fibrinolysis model was created by reconstituting plasminogen-deficient mice with human plasminogen. When compared with TPA, SKΔ1 and SKΔ59 were 4-fold (P < 0.0001) and 2-fold (P < 0.003) more potent at dissolving blood clots in vivo, respectively, on a mass-dose basis and 2–3 logs more potent than TPA (P < 0.0001) when doses were calibrated by standard activity assays. Conclusion: These experiments suggest that reprogramming SK’s mechanism of action markedly enhances fibrin-targeting and creates, in comparison with TPA, activators with greater fibrinolytic potency. PMID:19566545
Sazonova, I Y; McNamee, R A; Houng, A K; King, S M; Hedstrom, L; Reed, G L
2009-08-01
Given the worldwide epidemic of cardiovascular diseases, a more effective means of dissolving thrombi that cause heart attacks, could markedly reduce death, disability and healthcare costs. Plasminogen activators (PAs) such as streptokinase (SK) and tissue plasminogen activator (TPA) are currently used to dissolve fibrin thrombi. SK is cheaper and more widely available, but it appears less effective because it lacks TPA's fibrin-targeted properties that focus plasminogen activation on the fibrin surface. We examined whether re-programming SK's mechanism of action would create PAs with greater fibrin-targeting and potency than TPA. When fibrinogen consumption was measured in human plasma, reprogrammed molecules SKDelta1 and SKDelta59 were 5-fold and > 119-fold more fibrin-dependent than SK (P < 0.0001), and 2-fold and > 50-fold more fibrin-dependent than TPA (P < 0.001). The marked fibrin-targeting of SKDelta59 was due to the fact that: (i) it did not generate plasmin in plasma, (ii) it was rapidly inhibited by alpha2-antiplasmin, and (iii) it only processed fibrin-bound plasminogen. To assess the fibrin-targeting and therapeutic potential of these PAs in vivo, a novel 'humanized' fibrinolysis model was created by reconstituting plasminogen-deficient mice with human plasminogen. When compared with TPA, SKDelta1 and SKDelta59 were 4-fold (P < 0.0001) and 2-fold (P < 0.003) more potent at dissolving blood clots in vivo, respectively, on a mass-dose basis and 2-3 logs more potent than TPA (P < 0.0001) when doses were calibrated by standard activity assays. These experiments suggest that reprogramming SK's mechanism of action markedly enhances fibrin-targeting and creates, in comparison with TPA, activators with greater fibrinolytic potency.
Thrombin generation and fibrin formation under flow on biomimetic tissue factor-rich surfaces.
Onasoga-Jarvis, A A; Puls, T J; O'Brien, S K; Kuang, L; Liang, H J; Neeves, K B
2014-01-01
Blood flow regulates coagulation and fibrin assembly by controlling the rate of transport of zymogens, enzymes and plasma proteins to and from the site of an injury. The objective of this work was to define the hemodynamic conditions under which fibrin can form under flow on tissue factor (TF)-rich substrates. TF-coated silica beads (~ 800 nm) were patterned into 18-85-μm spots. Normal pooled plasma and factors VIII, IX and XI deficient plasmas were perfused over the beads coated with 0.08, 0.8 and 8 molecules-TF μm(-2) at shear rates of 50-1000 s(-1) . Fibrin deposition and thrombin generation were measured by fluorescence microscopy in a hydrodynamic focusing microfluidic device. Fibrin deposition was supported on patterned bead spots, but not planar TF substrates at the same surface TF concentration. There was a threshold spot size and a shear rate dependent TF concentration that was necessary to support fibrin polymerization. FVIII and FIX had minor effects on fibrin dynamics at 8 molecules-TF μm(-2) , but were essential at 0.8 molecules-TF μm(-2) . The absence of FXI influenced thrombin generation and fibrin deposition at both 0.8 and 8 molecules-TF μm(-2) . These results show that fibrin deposition requires perturbations in the flow field that protect reactions from dilution by flow under venous and arterial conditions. FVIII and FIX have a modest effect on fibrin deposition at high TF concentrations, but are necessary for fibrin deposition at low TF concentrations. FXI amplifies thrombin generation under flow at both low and high TF concentrations. © 2013 International Society on Thrombosis and Haemostasis.
Validation of hot-poured crack sealant performance-based guidelines.
DOT National Transportation Integrated Search
2017-06-01
This report summarizes a comprehensive research effort to validate thresholds for performance-based guidelines and : grading system for hot-poured asphalt crack sealants. A series of performance tests were established in earlier research and : includ...
Adhesion testing procedure for hot-poured crack sealants.
DOT National Transportation Integrated Search
2008-11-01
Crack sealing is a common pavement maintenance treatment because it extends pavement service life significantly. : However, crack sealant often fails prematurely due to a loss of adhesion. Because current test methods are mostly : empirical and only ...
Field manual for crack sealing in asphalt pavements.
DOT National Transportation Integrated Search
2006-01-01
This field manual was developed as a product of research project 4061 Comparison of Hot Poured Crack Sealant to Emulsified Asphalt Crack Sealant conducted by The University of Texas at Austin Center for Transportation Research (CTR). Organizati...
Development of new photopolymerizable dental sealants.
Davidenko, N; Cohen, M E; Diaz, J M; Sastre, R
1998-01-01
This paper describes the results obtained in the optimization of the composition of dental sealants in relation to the nature and proportions of monomer mixtures and photoinitiating system employed. The quantification and variation of certain parameters which determine the quality of a dental sealant (such as viscosity and penetrating power, residual double bonds, solubility and absorption, volume shrinkage and certain specific mechanical properties) have resulted in the development of new formulations. The composition which has achieved the best results of all the above properties was that corresponding to the monomer mixture bis-GMA/tri(ethylene glycol) dimethacrylate (TEGDMA) 40/60 wt%, and the photoinitiating system camphorquinone (CQ) with co-initiators N,N,3,5-tetramethyaniline (TMA) or N,N-dimethyl-p-toluidine (DMPT) in the ratio 1:1. The final properties and characteristics of the obtained formulations are superior to those of commercial dental sealants currently in use.
An in-vitro evaluation of mechanical and esthetic properties of orthodontic sealants
Premaraj, Thyagaseely Sheela; Rohani, Nima; Covey, David; Premaraj, Sundaralingam; Hua, Yi; Watanabe, Hidehiko
2014-01-01
Objective: To evaluate mechanical and esthetic Properties of two commercially available orthodontic sealants: Opal®Seal (OS) and L.E.D. Pro Seal (PS). Materials and Methods: Discs of each sealant were prepared to test the following properties: Micro hardness, wear resistance and color stability. Samples were randomly selected after the wear test for SEM imaging to analyze surface morphology. Results: OS was significantly harder than PS (P < 0.001). PS was significantly more wear resistant than OS (P < 0.05). PS showed a greater ∆E*ab (increased staining) when placed in wine or coffee showing a significant difference (P < 0.05). SEM showed particle size, shape and distribution were different for PS and OS reflecting the pattern seen on wear surfaces. Conclusion: Both orthodontic sealants are beneficial for protecting enamel. However with better wear properties PS was superior in resisting mechanical stresses. OS was more color stable. PMID:25512729
Yesilirmak, Nilufer; Diakonis, Vasilios F; Battle, Juan F; Yoo, Sonia H
2015-04-01
To report a case of clinically significant epithelial ingrowth after LASIK that was successfully treated with a hydrogel ocular sealant in combination with flap lifting and scraping technique. Case report. A 56-year-old woman underwent LASIK and a LASIK enhancement procedure in 2002 and 2012, respectively. Six months after the enhancement, visually significant epithelial ingrowth developed in both of her eyes. The left eye was treated with flap lifting, scraping, and suturing, and the right eye was treated with a hydrogel ocular sealant in combination with flap lifting and scraping. No recurrence was evident during a 6-month follow-up period and visual acuity improved in both eyes. No adverse effects were noticed. Recurrent epithelial ingrowth may be successfully avoided with the intraoperative use of a hydrogel ocular sealant combined with flap lifting and scraping. This approach could be used as an alternative to LASIK flap suturing. Copyright 2015, SLACK Incorporated.
Fibrin structural and diffusional analysis suggests that fibers are permeable to solute transport.
Leonidakis, Kimon Alexandros; Bhattacharya, Pinaki; Patterson, Jennifer; Vos, Bart E; Koenderink, Gijsje H; Vermant, Jan; Lambrechts, Dennis; Roeffaers, Maarten; Van Oosterwyck, Hans
2017-01-01
Fibrin hydrogels are promising carrier materials in tissue engineering. They are biocompatible and easy to prepare, they can bind growth factors and they can be prepared from a patient's own blood. While fibrin structure and mechanics have been extensively studied, not much is known about the relation between structure and diffusivity of solutes within the network. This is particularly relevant for solutes with a size similar to that of growth factors. A novel methodological approach has been used in this study to retrieve quantitative structural characteristics of fibrin hydrogels, by combining two complementary techniques, namely confocal fluorescence microscopy with a fiber extraction algorithm and turbidity measurements. Bulk rheological measurements were conducted to determine the impact of fibrin hydrogel structure on mechanical properties. From these measurements it can be concluded that variations in the fibrin hydrogel structure have a large impact on the rheological response of the hydrogels (up to two orders of magnitude difference in storage modulus) but only a moderate influence on the diffusivity of dextran solutes (up to 25% difference). By analyzing the diffusivity measurements by means of the Ogston diffusion model we further provide evidence that individual fibrin fibers can be semi-permeable to solute transport, depending on the average distance between individual protofibrils. This can be important for reducing mass transport limitations, for modulating fibrinolysis and for growth factor binding, which are all relevant for tissue engineering. Fibrin is a natural biopolymer that has drawn much interest as a biomimetic carrier in tissue engineering applications. We hereby use a novel combined approach for the structural characterization of fibrin networks based on optical microscopy and light scattering methods that can also be applied to other fibrillar hydrogels, like collagen. Furthermore, our findings on the relation between solute transport and fibrin structural properties can lead to the optimized design of fibrin hydrogel constructs for controlled release applications. Finally, we provide new evidence for the fact that fibrin fibers may be permeable for solutes with a molecular weight comparable to that of growth factors. This finding may open new avenues for tailoring mass transport properties of fibrin carriers. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Differential regulation of macrophage inflammatory activation by fibrin and fibrinogen.
Hsieh, Jessica Y; Smith, Tim D; Meli, Vijaykumar S; Tran, Thi N; Botvinick, Elliot L; Liu, Wendy F
2017-01-01
Fibrin is a major component of the provisional extracellular matrix formed during tissue repair following injury, and enables cell infiltration and anchoring at the wound site. Macrophages are dynamic regulators of this process, advancing and resolving inflammation in response to cues in their microenvironment. Although much is known about how soluble factors such as cytokines and chemokines regulate macrophage polarization, less is understood about how insoluble and adhesive cues, specifically the blood coagulation matrix fibrin, influence macrophage behavior. In this study, we observed that fibrin and its precursor fibrinogen elicit distinct macrophage functions. Culturing macrophages on fibrin gels fabricated by combining fibrinogen with thrombin stimulated secretion of the anti-inflammatory cytokine, interleukin-10 (IL-10). In contrast, exposure of macrophages to soluble fibrinogen stimulated high levels of inflammatory cytokine tumor necrosis factor alpha (TNF-α). Macrophages maintained their anti-inflammatory behavior when cultured on fibrin gels in the presence of soluble fibrinogen. In addition, adhesion to fibrin matrices inhibited TNF-α production in response to stimulation with LPS and IFN-γ, cytokines known to promote inflammatory macrophage polarization. Our data demonstrate that fibrin exerts a protective effect on macrophages, preventing inflammatory activation by stimuli including fibrinogen, LPS, and IFN-γ. Together, our study suggests that the presentation of fibrin(ogen) may be a key switch in regulating macrophage phenotype behavior, and this feature may provide a valuable immunomodulatory strategy for tissue healing and regeneration. Fibrin is a fibrous protein resulting from blood clotting and provides a provisional matrix into which cells migrate and to which they adhere during wound healing. Macrophages play an important role in this process, and are needed for both advancing and resolving inflammation. We demonstrate that culture of macrophages on fibrin matrices exerts an anti-inflammatory effect, whereas the soluble precursor fibrinogen stimulates inflammatory activation. Moreover, culture on fibrin completely abrogates inflammatory signaling caused by fibrinogen or known inflammatory stimuli including LPS and IFN-γ. Together, these studies show that the presentation of fibrin(ogen) is important for regulating a switch between macrophage pro- and anti-inflammatory behavior. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Evaluation of 111In-labeled EPep and FibPep as tracers for fibrin SPECT imaging.
Starmans, Lucas W E; van Duijnhoven, Sander M J; Rossin, Raffaella; Berben, Monique; Aime, Silvio; Daemen, Mat J A P; Nicolay, Klaas; Grüll, Holger
2013-11-04
Fibrin targeting is an attractive strategy for nuclear imaging of thrombosis, atherosclerosis and cancer. Recently, FibPep, an (111)In-labeled fibrin-binding peptide, was established as a tracer for fibrin SPECT imaging and was reported to allow sensitive detection of minute thrombi in mice using SPECT. In this study, we developed EPep, a novel (111)In-labeled fibrin-binding peptide containing the fibrin-binding domain of the clinically verified EP-2104R peptide, and sought to compare the potential of EPep and FibPep as tracers for fibrin SPECT imaging. In vitro, both EPep and FibPep showed high stability in serum, but were less stable in liver and kidney homogenate assays. Both peptide probes displayed comparable affinities toward human and mouse derived fibrin (Kd ≈ 1 μM), and similarly to FibPep, EPep showed fast blood clearance, low nontarget uptake and high thrombus uptake (6.8 ± 1.2% ID g(-1)) in a mouse carotid artery thrombosis model. Furthermore, EPep showed a similar affinity toward rat derived fibrin (Kd ≈ 1 μM), displayed high thrombus uptake in a rat carotid artery thrombosis model (0.74 ± 0.39% ID g(-1)), and allowed sensitive detection of thrombosis in rats using SPECT. In contrast, FibPep displayed a significantly lower affinity toward rat derived fibrin (Kd ≈ 14 μM) and low uptake in rat thrombi (0.06 ± 0.02% ID g(-1)) and did not allow clear visualization of carotid artery thrombosis in rats using SPECT. These results were confirmed ex vivo by autoradiography, which showed a 7-fold higher ratio of activity in the thrombus over the contralateral carotid artery for EPep in comparison to FibPep. These findings suggest that the FibPep binding fibrin epitope is not fully homologous between humans and rats, and that preclinical rat models of disease should not be employed to gauge the clinical potential of FibPep. In conclusion, both peptides showed approximately similar metabolic stability and affinity toward human and mouse derived fibrin, and displayed high thrombus uptake in a mouse carotid artery thrombosis model. Therefore, both EPep and FibPep are promising fibrin targeted tracers for translation into clinical settings to serve as novel tools for molecular imaging of fibrin.
Hepdeniz, Ozge Kam; Temel, Ugur Burak; Ugurlu, Muhittin; Koskan, Ozgur
2016-01-01
Microleakage is still one of the most cited reasons for failure of resin composite restorations. Alternative methods to prevent microleakage have been investigated increasingly. The aim of this study is to evaluate the microleakage in Class V resin composite restorations with or without application of surface sealants with different filler content. Ninety-six cavities were prepared on the buccal and lingual surfaces with the coronal margins located in enamel and the cervical margins located in dentin. The cavities restored with an adhesive system (Clearfil SE Bond, Kuraray, Tokyo, Japan) and resin composite (Clearfil Majesty ES-2, Kuraray, Tokyo, Japan). Teeth were stored in distilled water for 24 h and separated into four groups according to the surface sealants (Control, Fortify, Fortify Plus, and G-Coat Plus). The teeth were thermocycled (500 cycles, 5-55° C), immersed in basic fuchsine, sectioned, and analyzed for dye penetration using stereomicroscope. The data were submitted to statistical analysis by Kruskal-Wallis and Bonferroni-Dunn test. The results of the study indicated that there was minimum leakage at the enamel margins of all groups. Bonferroni-Dunn tests revealed that Fortify and GC-Coat groups showed significantly less leakage than the Control group and the Fortify Plus group at dentin margins in lingual surfaces (P < 0.05). The all surface sealants used in this study eliminated microleakage at enamel margins. Moreover, unfilled or nanofilled surface sealants were the most effective in decreasing the degree of marginal microleakage at dentin margins. However, viscosity and penetrability of the sealants could be considered for sealing ability besides composition.
Development of apparent viscosity test for hot-poured crack sealants.
DOT National Transportation Integrated Search
2008-11-01
Current crack sealant specifications focuses on utilizing simple empirical tests such as penetration, : resilience, flow, and bonding to cement concrete briquettes (ASTM D3405) to measure the ability of the material : to resist cohesive and adhesion ...
Evaluation of joint sealant materials : final report.
DOT National Transportation Integrated Search
1977-05-01
In May, 1968, the Department's Research and Development Section initiated a project to evaluate joint sealants being marketed for use on roads and bridges. In the study, representatives of 31 companies installed 40 products primarily on one road and ...
Reflectivity of crack sealant.
DOT National Transportation Integrated Search
2002-01-01
Crack sealing is used in road maintenance but presents a problem when crack seal material visually pops out on the roadway, making it difficult to see lane stripes. This problem will increase as New Mexico increases its use of crack sealants. This su...
Field evaluation of three joint sealants.
DOT National Transportation Integrated Search
1987-01-01
The purpose of the study reported here was to evaluate the performance of three joint sealants compartmented (A) and closed cellular (B) preformed neoprene, and a two-component cold-mixed polysulfide (C)-- that were used in the interchanges for Inter...
Prevalence of Dental Caries and Fissure Sealants in a Portuguese Sample of Adolescents
Veiga, Nélio J.; Pereira, Carlos M.; Ferreira, Paula C.; Correia, Ilidio J.
2015-01-01
Introduction The aims of this study were to assess the prevalence of dental caries and the DMFT index, as well as the distribution pattern of pit and fissure sealants on permanent teeth in a Portuguese sample of adolescents, and to assess whether the existing usage of sealants and socio-demographic factors are correlated to caries prevalence on the examined sample. Materials and Methods A cross-sectional study was designed with a sample of 447 adolescents aged 12 to 18 years old, attending a public school in Sátão, Portugal. A self-administered questionnaire with questions about oral health behaviours and socio-economic status was answered by adolescents in the classroom. Clinical examination of oral health status and assessment of fissure sealants were accomplished by only one trained member of the research team. Results We obtained a DMFT index of 3.32 (2.92), which indicates a moderate level of prevalence of dental caries. When considering a DMFT = 0, we found significant statistical differences between the parents´ level of education (≤ 4th grade = 26.3 vs 5th–12th grade = 18.8 vs <12th grade = 43.3, p = 0.001), gender (male = 27.3 vs female = 19.6, p = 0.04), age (≤15 years = 27.1 vs <15 years = 18.5, p = 0.02), presence of fissure sealants (yes = 30.6 vs no = 13.5, p = 0.001) and experience of dental pain (no = 25.4 vs yes = 16.8, p = 0.02). When analyzing the prevalence of fissure sealants, we verified that 58.8% of adolescents had at least one fissure sealant applied. Significant statistical differences were found when analyzing the presence of fissure sealants related with parents´educational level (<9th grade, OR = 1.56 CI95% = 1.05–2.54), gender (female, OR = 1.86 CI95% = 1.19–2.98), experience of dental pain (yes, OR = 0.62 CI95% = 0.39–0.97) and presence of dental caries (yes, OR = 0.35 CI95% = 0.19–0.65). Conclusions The moderate level of caries prevalence reveals the need of improvement of primary prevention interventions among Portuguese adolescents. The establishment of a more targeted preventive program with better and more effective oral health education is essential, having into account socio-demographic aspects. PMID:25803849
Thrombin-dependent Incorporation of von Willebrand Factor into a Fibrin Network*
Miszta, Adam; Pelkmans, Leonie; Lindhout, Theo; Krishnamoorthy, Ganeshram; de Groot, Philip G.; Hemker, Coenraad H.; Heemskerk, Johan W. M.; Kelchtermans, Hilde; de Laat, Bas
2014-01-01
Attachment of platelets from the circulation onto a growing thrombus is a process involving multiple platelet receptors, endothelial matrix components, and coagulation factors. It has been indicated previously that during a transglutaminase reaction activated factor XIII (FXIIIa) covalently cross-links von Willebrand factor (VWF) to polymerizing fibrin. Bound VWF further recruits and activates platelets via interactions with the platelet receptor complex glycoprotein Ib (GPIb). In the present study we found proof for binding of VWF to a fibrin monomer layer during the process of fibrinogen-to-fibrin conversion in the presence of thrombin, arvin, or a snake venom from Crotalus atrox. Using a domain deletion mutant we demonstrated the involvement of the C domains of VWF in this binding. Substantial binding of VWF to fibrin monomers persisted in the presence of the FXIIIa inhibitor K9-DON, illustrating that cross-linking via factor XIII is not essential for this phenomenon and suggesting the identification of a second mechanism through which VWF multimers incorporate into a fibrin network. Under high shear conditions, platelets were shown to adhere to fibrin only if VWF had been incorporated. In conclusion, our experiments show that the C domains of VWF and the E domain of fibrin monomers are involved in the incorporation of VWF during the polymerization of fibrin and that this incorporation fosters binding and activation of platelets. Fibrin thus is not an inert end product but partakes in further thrombus growth. Our findings help to elucidate the mechanism of thrombus growth and platelet adhesion under conditions of arterial shear rate. PMID:25381443
The disulfide isomerase ERp57 is required for fibrin deposition in vivo.
Zhou, J; Wu, Y; Wang, L; Rauova, L; Hayes, V M; Poncz, M; Essex, D W
2014-11-01
ERp57 is required for platelet function; however, whether ERp57 contributes to fibrin generation is unknown. Using an inhibitory anti-ERp57 antibody (mAb1), Pf4-Cre/ERp57(fl/fl) mice, Tie2-Cre/ERp57(fl/fl) mice, and mutants of ERp57, we analyzed the function of ERp57 in laser-induced thrombosis. Fibrin deposition was decreased in Pf4-Cre/ERp57(fl/fl) mice, consistent with a role for platelet ERp57 in fibrin generation. Fibrin deposition was further decreased with infusion of mAb1 and in Tie2-Cre/ERp57(fl/fl) mice, consistent with endothelial cells also contributing to fibrin deposition. Infusion of eptibifatide inhibited platelet and fibrin deposition, confirming a role for platelets in fibrin deposition. Infusion of recombinant ERp57 corrected the defect in fibrin deposition but not platelet accumulation, suggesting a direct effect of ERp57 on coagulation. mAb1 inhibited thrombin generation in vitro, consistent with a requirement for ERp57 in coagulation. Platelet accumulation was decreased to similar extents in Pf4-Cre/ERp57(fl/fl) mice, Tie2-Cre/ERp57(fl/fl) mice and normal mice infused with mAb1. Infusion of completely inactivated ERp57 or ERp57 with a non-functional second active site inhibited fibrin deposition and platelet accumulation, indicating that the isomerase activity of the second active site is required for these processes. ERp57 regulates thrombosis via multiple targets. © 2014 International Society on Thrombosis and Haemostasis.
Yokota, M; Basi, D L; Herzberg, M C; Meyer, M W
2001-01-01
In Streptococcus sanguinis (sanguis) induced experimental endocarditis, we sought evidence that the development of aortic valvular vegetation depends on the availability of fibrin. Endocarditis was induced in New Zealand white rabbits by catheter placement into the left ventricle and inoculation of the bacteria. Fibrin was localized in the developing vegetation with 99mTechnetium (Tc)-labeled anti-fibrin antibody one or three days later. When rabbit anti-fibrin antibody was given intravenously on day 1, the mass of aortic valvular vegetation was significantly reduced at day 3; infusion of non-specific rabbit IgG showed no effect. The 99mTc-labeled anti-fibrin antibody also labeled kidneys that showed macroscopic subcapsular hemorrhage. To learn if the deposition of fibrin in the kidneys was a consequence of endocarditis required a comparison of farm-bred and specific pathogen-free rabbits before and after the induction of endocarditis. Before induction, the kidneys of farm-bred rabbits were labeled, but specific pathogen-free rabbits were free of labeling and signs of macroscopic hemorrhage. After 3 days of endocarditis, kidneys of 10 of 14 specific pathogen-free rabbits labeled with 99mTc-labeled anti-fibrin antibody and showed hemorrhage. Kidney lesions were suggested to be a frequent sequellae of S. sanguinis infective endocarditis. For the first time, fibrin was shown to be required for the continued development of aortic valvular vegetations.
Kouketsu, Atsumu; Nogami, Shinnosuke; Yamada-Fujiwara, Minami; Nagai, Hirokazu; Yamauchi, Kensuke; Mori, Shiro; Miyashita, Hitoshi; Kawai, Tadashi; Matsui, Aritsune; Kataoka, Yoshihiro; Satomi, Norihisa; Ezoe, Yushi; Abe, Satoko; Takeda, Yuri; Tone, Takeshi; Hirayama, Bunnichi; Kurobane, Tsuyoshi; Tashiro, Kazuki; Yanagisawa, Yuta; Takahashi, Tetsu
2017-09-01
The CryoSeal ® FS System has been recently introduced as an automated device for the production of complete fibrin glue from autologous plasma, rather than from pool allogenic or cattle blood, to prevent viral infection and allergic reaction. We evaluated the effectiveness of complete autologous fibrin glue and polyglycolic acid (PGA) sheet wound coverings in mucosa defect oral surgery. Postoperative pain, scar contracture, ingestion, tongue dyskinesia, and postoperative bleeding were evaluated in 12 patients who underwent oral (including the tongue) mucosa excision, and received a PGA sheet and an autologous fibrin glue covering. They were compared with 12 patients who received a PGA sheet and commercial allogenic fibrin glue. All cases in the complete autologous fibrin glue group demonstrated good wound healing without complications such as local infection or incomplete cure. All evaluated clinical measures in this group were similar or superior to the commercial allogenic fibrin glue group. Coagulation and adhesion quality achieved with this method was comparable to that with a PGA sheet and commercial fibrin glue. Covering oral surgery wounds with complete autologous fibrin glue produced by an automated device was convenient, safe, and reduced the risk of viral infection and allergic reaction associated with conventional techniques. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Fibrin gel as a scaffold for skin substitute – production and clinical experience.
Kljenak, Antun; Tominac Trcin, Mirna; Bujić, Marina; Dolenec, Tamara; Jevak, Martina; Mršić, Gordan; Zmiš, Gordana; Barčot, Zoran; Muljačić, Ante; Popović, Maja
2016-06-01
The purpose of this study was to create a fibrin-based human skin substitute in vitro with epidermal and dermal component and to assess its healing potential in deep partial and full thickness burns. Fibrin scaffolds were prepared from commercial fibrin glue kits. Human fibroblasts were cultured in fibrin gel. Human keratinocytes were seeded on the top of the gel. Viability of cells was determined fluorimetrically. Scanning electron microscope and immunocytochemistry analysis of cultured cells were performed. After hydrosurgical preparation of deep burn necrotic tissue, wound bed was prepared for skin substitutes. Progress of healing was documented using visual estimation and photos. Scanning electron microscope images showed good cell attachment and colony spreading of keratinocytes and fibroblasts on fibrin scaff old. Immunofluorescent staining of cell cultures on fibrin scaffold showed expression of vimentin, a marker of fibroblast cells, cytokeratin 19, a marker of epithelial stem cells, as well as involucrin, a marker of differentiated keratinocytes. Clinical results clearly showed that appearance of the skin did not differ significantly from the areas of transplanted skin using split-thickness skin graft techniques. In conclusion, using these fibrin-cultured autografts on massive full-thickness burn resulted in good healing.
Bacakova, Marketa; Pajorova, Julia; Stranska, Denisa; Hadraba, Daniel; Lopot, Frantisek; Riedel, Tomas; Brynda, Eduard; Zaloudkova, Margit; Bacakova, Lucie
2017-01-01
Protein-coated resorbable synthetic polymeric nanofibrous membranes are promising for the fabrication of advanced skin substitutes. We fabricated electrospun polylactic acid and poly(lactide- co -glycolic acid) nanofibrous membranes and coated them with fibrin or collagen I. Fibronectin was attached to a fibrin or collagen nanocoating, in order further to enhance the cell adhesion and spreading. Fibrin regularly formed a coating around individual nanofibers in the membranes, and also formed a thin noncontinuous nanofibrous mesh on top of the membranes. Collagen also coated most of the fibers of the membrane and randomly created a soft gel on the membrane surface. Fibronectin predominantly adsorbed onto a thin fibrin mesh or a collagen gel, and formed a thin nanofibrous structure. Fibrin nanocoating greatly improved the attachment, spreading, and proliferation of human dermal fibroblasts, whereas collagen nanocoating had a positive influence on the behavior of human HaCaT keratinocytes. In addition, fibrin stimulated the fibroblasts to synthesize fibronectin and to deposit it as an extracellular matrix. Fibrin coating also showed a tendency to improve the ultimate tensile strength of the nanofibrous membranes. Fibronectin attached to fibrin or to a collagen coating further enhanced the adhesion, spreading, and proliferation of both cell types.
Bacakova, Marketa; Pajorova, Julia; Stranska, Denisa; Hadraba, Daniel; Lopot, Frantisek; Riedel, Tomas; Brynda, Eduard; Zaloudkova, Margit; Bacakova, Lucie
2017-01-01
Protein-coated resorbable synthetic polymeric nanofibrous membranes are promising for the fabrication of advanced skin substitutes. We fabricated electrospun polylactic acid and poly(lactide-co-glycolic acid) nanofibrous membranes and coated them with fibrin or collagen I. Fibronectin was attached to a fibrin or collagen nanocoating, in order further to enhance the cell adhesion and spreading. Fibrin regularly formed a coating around individual nanofibers in the membranes, and also formed a thin noncontinuous nanofibrous mesh on top of the membranes. Collagen also coated most of the fibers of the membrane and randomly created a soft gel on the membrane surface. Fibronectin predominantly adsorbed onto a thin fibrin mesh or a collagen gel, and formed a thin nanofibrous structure. Fibrin nanocoating greatly improved the attachment, spreading, and proliferation of human dermal fibroblasts, whereas collagen nanocoating had a positive influence on the behavior of human HaCaT keratinocytes. In addition, fibrin stimulated the fibroblasts to synthesize fibronectin and to deposit it as an extracellular matrix. Fibrin coating also showed a tendency to improve the ultimate tensile strength of the nanofibrous membranes. Fibronectin attached to fibrin or to a collagen coating further enhanced the adhesion, spreading, and proliferation of both cell types. PMID:28223803
Fibrin facilitates both innate and T cell-mediated defense against Yersinia pestis.1
Luo, Deyan; Lin, Shiuan; Parent, Michelle A.; Kanevsky, Isis Mullarky; Szaba, Frank M.; Kummer, Lawrence W.; Duso, Debra K.; Tighe, Michael; Hill, Jim; Gruber, Andras; Mackman, Nigel; Gailani, David; Smiley, Stephen T.
2013-01-01
The gram-negative bacterium Yersinia pestis causes plague, a rapidly progressing and often fatal disease. The formation of fibrin at sites of Y. pestis infection supports innate host defense against plague, perhaps by providing a non-diffusible spatial cue that promotes the accumulation of inflammatory cells expressing fibrin-binding integrins. This report demonstrates that fibrin is an essential component of T cell-mediated defense against plague but can be dispensable for antibody-mediated defense. Genetic or pharmacologic depletion of fibrin abrogated innate and T cell-mediated defense in mice challenged intranasally with Y. pestis. The fibrin-deficient mice displayed reduced survival, increased bacterial burden, and exacerbated hemorrhagic pathology. They also showed fewer neutrophils within infected lung tissue and reduced neutrophil viability at sites of liver infection. Depletion of neutrophils from wild type mice weakened T cell-mediated defense against plague. The data suggest that T cells combat plague in conjunction with neutrophils, which require help from fibrin in order to withstand Y. pestis encounters and effectively clear bacteria. PMID:23487423
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, Elvie; Hu, Dehong; Abu-Lail, Nehal
2013-02-19
Nanocrystalline cellulose, a new bio-nanomaterial is utilized as a reinforcing material for biocompatible fibrin matrix to form into a nanocomposite for small-diameter replacement vascular graft application (SDRVG). The periodate oxidation of NCC, which provided it with a reactive carbonyl group, allowed molecular interaction between NCC and fibrin. Such interaction resulted into an effective mechanical reinforcement indicated by the improvement of max. force, elongation at break and modulus when oxidized NCC (ONCC) was incorporated into fibrin. The nanocomposite’s mechanical properties can be manipulated to conform to the native blood vessel by varying the ONCC to fibrin ratio and/or by controlling themore » degree of oxidation of NCC. Using atomic force microscopy had provided fundamental information on the effects of molecular interactions to the nanolevel mechanical properties of NCC/fibrin nanocomposites. This fundamental information established the positive feasibility and commenced continuing investigation for the practical SDRVG application of NCC/fibrin nanocomposite.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-07
... firm. The workers are engaged in the production of adhesives and sealants. New information shows that... were adversely affected by a shift in the production of adhesives and sealants to the United Kingdom...
Owens, Barry M; Sharp, Harry K; Fourmy, Emily E; Phebus, Jeffrey G
2016-01-01
The aim of this case report and in vitro investigation was to evaluate the marginal microleakage of intact occlusal calculus of primary molars extracted from a special needs patient who received nutrition via a gastric feeding tube. An adolescent with a history of developmental disturbance presented for routine dental care in a hospital facility. Prophylaxis was performed, and 2 mandibular permanent molars were restored. Five primary molars were extracted due to mobility and delayed retention. Heavy deposits of intact calculus were present on the occlusal surfaces of the primary teeth. The extracted teeth were immersed in methylene blue dye solution, invested in acrylic resin, sectioned into blocks, and photographed at 20× and 40× magnification. Previously photographed calculus-free molars with pit and fissure sealants were reviewed and served as contrasting "restorations." The occlusal calculus on the primary teeth extracted from the patient absorbed the dye, while the comparison teeth containing pit and fissure sealants exhibited varying degrees of marginal dye penetration (microleakage). No marginal microleakage was noted in the calculus specimens, indicating that this substrate may serve as a "natural" occlusal surface sealant and that its removal from occlusal surfaces during routine oral prophylaxis may be unnecessary.
Exploring the determinants of secular decreases in dental caries among Korean children.
Lee, Hye-Ju; Han, Dong-Hun
2015-08-01
The aim of this study was to determine the contributions of sealant and water fluoridation to the time trends in dental caries from 2003 to 2010. Data were from three waves of the Korean National Oral Health Surveys between 2003 and 2010, including a total of 23 059 children (11 889 boys and 11 170 girls) aged 8, 10, and 12 years. The impacts of sealant and water fluoridation on dental caries were obtained by logistic regression for each age group of children. The contributions of sealant and water fluoridation to the time trends in the prevalence of dental caries were examined by a series of logistic regression models, and changes in the adjusted odds ratios for each survey year were also calculated. Over the past 7 years, the prevalence of dental caries decreased dramatically. Although sealant had a significant impact on dental caries in each survey year, remarkable decreases in dental caries from 2003 to 2010 were not explained by the secular changes in the dental sealant or water fluoridation factor. We observed important population declines in dental caries in Korea in children aged 8-12 years; however, the likely causes for these secular trends remain to be determined. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
The utilization of dental hygiene students in school-based dental sealant programs.
Miller, Faith Y
2005-01-01
Early detection of childhood caries is important to childrens' overall health. Untreated childhood caries can lead to pain, as in abscesses from prolonged neglect; altered dietary intake; and delays in the development of the permanent teeth if the primary teeth are prematurely lost. In the summer of 2000, funds were provided to various oral health care provider organizations by the Illinois Department of Public Health, Division of Oral Health, to purchase portable equipment to deliver preventive services (i.e., exams, sealants, and oral hygiene education) to second-grade and sixth-grade children who qualified for Medicaid and/or free and reduced-cost lunch programs. The Dental Sealant Grant Program at Southern Illinois University in Carbondale was a unique program that utilized dental hygiene students as the primary human resource. Within the state, the Dental Sealant Grant Program was, at the time of this report, the only grantee sponsored by a stand-alone dental hygiene program (not affiliated with a dental school). Other positive aspects of the dental hygiene-sponsored sealant program were that the supervising dentist was the primary Medicaid provider and a member of the dental hygiene faculty; dental hygiene faculty participated actively as site coordinators and clinicians; and dental hygiene students were given the opportunity to volunteer for the program as a service-learning option.
McDougall, S; Parker, K I; Weir, A M; Compton, C W R
2008-06-01
To assess the effect of applying an external teat sealant or a slow-release intraruminal monensin capsule pre-calving on the prevalence and incidence of subclinical or clinical mastitis in dairy heifers post-calving. The studies were undertaken in 13 herds. In two herds application of an external teat sealant was compared with a negative control; in nine herds treatment with monensin was compared with controls, and in two herds treatments were applied in a 2 x 2 factorial design. Heifers were randomly assigned within herd to be treated with a slow-release intraruminal device containing 32 g monensin (n=383), or left as untreated controls (n=389), approximately 30 days before the start of the spring calving period; or to be treated with a latex external teat sealant (n=206) when calving was impending, or be left as untreated controls (n=205). Milk samples were collected from each gland between 0 and 5 days after calving and from any gland diagnosed with clinical mastitis. The effect of the treatments on the prevalence of intramammary infection (IMI), i.e. subclinical mastitis, and clinical mastitis were initially analysed at the univariate level, with associated variables (p<0.2) being used in construction of multivariable models. The prevalence of IMI was 18.4% at the gland level, and coagulase-negative staphylococci followed by Streptococcus uberis were the most common isolates. Treatment with an external teat sealant reduced the prevalence, compared with controls, of any IMI (12.1 (SE 1.7)% vs 16.5 (SE 2.1)%, respectively; p=0.05) or IMI caused by a major pathogen (3.8 (SE 0.8)% vs 6.0 (SE 1.1)%, respectively; p=0.05). Monensin treatment did not affect the prevalence of any IMI (p=0.68) or IMI due to a major pathogen (p=0.11). The cumulative incidence of clinical mastitis was 14.2%. Neither monensin treatment (p=0.47) nor application of an external teat sealant (p=0.71) altered the risk of clinical mastitis. There was no interaction between the monensin and external teat sealant in the two herds where the treatments were applied in a 2 x 2 factorial design. Application of an external teat sealant resulted in a lower prevalence of any IMI and of an IMI caused by a major pathogen. Despite monensin reducing the mobilisation of body tissue and the risk of subclinical ketosis, it had no effect on the prevalence or incidence of IMI or clinical mastitis. Application of an external teat sealant is an option for reducing the prevalence of IMI in pasture fed dairy heifers.
Scaffold architecture and fibrin gels promote meniscal cell proliferation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pawelec, K. M., E-mail: pawelec.km@gmail.com, E-mail: jw626@cam.ac.uk; Best, S. M.; Cameron, R. E.
2015-01-01
Stability of the knee relies on the meniscus, a complex connective tissue with poor healing ability. Current meniscal tissue engineering is inadequate, as the signals for increasing meniscal cell proliferation have not been established. In this study, collagen scaffold structure, isotropic or aligned, and fibrin gel addition were tested. Metabolic activity was promoted by fibrin addition. Cellular proliferation, however, was significantly increased by both aligned architectures and fibrin addition. None of the constructs impaired collagen type I production or triggered adverse inflammatory responses. It was demonstrated that both fibrin gel addition and optimized scaffold architecture effectively promote meniscal cell proliferation.
... with other blood proteins to form fibrin. Fibrin strands form a net that entraps more platelets and ... that is normally dissolved in blood, into long strands of fibrin that radiate from the clumped platelets ...
Microporous nanofibrous fibrin-based scaffolds for craniofacial bone tissue engineering
NASA Astrophysics Data System (ADS)
Osathanon, Thanaphum
The fibrotic response of the body to synthetic polymers limits their success in tissue engineering and other applications. Though porous polymers have demonstrated improved healing, difficulty in controlling their pore sizes and pore interconnections has clouded the understanding of this phenomenon. In this study, a novel method to fabricate natural polymer/calcium phosphate composite scaffolds and immobilized alkaline phosphatase fibrin scaffolds with tightly controllable pore size, pore interconnection has been investigated. Microporous, nanofibrous fibrin scaffolds (FS) were fabricated using sphere-templating method. Calcium phosphate/fibrin composite scaffolds were created by solution deposition of calcium phosphate on fibrin surfaces or by direct incorporation of nanocrystalline hydroxyapatite (nHA). The SEM results showed that fibrin scaffolds exhibited a highly porous and interconnected structure. Osteoblast-like cells, obtained from murine calvaria, attached, spread and showed a polygonal morphology on the surface of the biomaterial. Multiple cell layers and fibrillar matrix deposition were observed. Moreover, cells seeded on mineralized fibrin scaffolds (MFS) exhibited significantly higher alkaline phosphatase activity as well as osteoblast marker gene expression compared to FS and nHA incorporated fibrin scaffolds (nHA/FS). These fibrin-based scaffolds were degraded both in vitro and in vivo. Furthermore, these scaffolds promoted bone formation in a mouse calvarial defect model and the bone formation was enhanced by addition of rhBMP-2. The second approach was to immobilize alkaline phosphatase (ALP) on fibrin scaffolds. ALP enzyme was covalently immobilized on the microporous nanofibrous fibrin scaffolds using 1-ethyl-3-(dimethylaminopropyl)carbodiimide hydrochloride (EDC). The SEM results demonstrated mineral deposition on immobilized ALP fibrin scaffolds (ALP/FS) when incubated in medium supplemented with beta-glycerophosphate, suggesting that the immobilized ALP enzyme was active. Mineral deposition was also observed in cells seeded on immobilized ALP/FS. Furthermore, cells seeded on immobilized ALP/FS exhibited higher osteoblast marker gene expression compared to those on control FS. Upon implantation in mouse calvarial defect, the immobilized ALP/FS treated group had slightly higher bone volume in the defect compared to empty defect control and FS alone. In conclusion, the enhanced biological responses both in vitro and in vivo demonstrated the potential application of these novel microporous nanofibrous fibrin-based scaffolds for bone tissue engineering.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., threaded, socket, or compression fittings. Gaskets and thread sealants shall be suitable for hydrogen... closures. (v) Piping, tubing, and fittings. (a) Piping, tubing, and fittings and gasket and thread sealants... including process or analytical equipment. (c) Be located 25 feet from concentrations of people. (d) Be...
Characterization of low temperature creep properties of crack sealants using bending beam rehometry.
DOT National Transportation Integrated Search
2009-11-01
Crack sealing has been widely used as a routine preventative maintenance practice. Given its proper installation, crack sealants can extend : pavement service life by three to five years. However, current specifications for the selection of crack sea...
DOT National Transportation Integrated Search
2008-11-01
Crack sealing has been widely used as a routine preventative maintenance practice. Given its proper : installation, crack sealants can extend pavement service life by three to five years. However, current : specifications for the selection of crack s...
Three-dimensional structure and cytokine distribution of platelet-rich fibrin.
Bai, Meng-Yi; Wang, Ching-Wei; Wang, Jyun-Yi; Lin, Ming-Fang; Chan, Wing P
2017-02-01
Previous reports have revealed that several cytokines (including platelet-derived growth factor-BB, transforming growth factors-β1 and insulin-like growth factor-1) can enhance the rate of bone formation and synthesis of extracellular matrix in orthopaedics or periodontology. This study aimed to determine the concentration of cytokines within platelet-rich fibrin microstructures and investigate whether there are differences in the different portions of platelet-rich fibrin, which has implications for proper clinical use of platelet-rich fibrin gel. Whole blood was obtained from six New Zealand rabbits (male, 7 to 39 weeks old, weight 2.7-4 kg); it was then centrifuged for preparation of platelet-rich fibrin gels and harvest of plasma. The resultant platelet-rich fibrin gels were used for cytokine determination, histological analyses and scanning electron microscopy. All plasmas obtained were subject to the same cytokine determination assays for the purpose of comparison. Cytokines platelet-derived growth factor-BB and transforming growth factor-β1 formed concentration gradients from high at the red blood cell end of the platelet-rich fibrin gel (p=1.88×10-5) to low at the plasma end (p=0.19). Insulin-like growth factor-1 concentrations were similar at the red blood cell and plasma ends. The porosities of the platelet-rich fibrin samples taken in sequence from the red blood cell end to the plasma end were 6.5% ± 4.9%, 24.8% ± 7.5%, 30.3% ± 8.5%, 41.4% ± 12.3%, and 40.3% ± 11.7%, respectively, showing a gradual decrease in the compactness of the platelet-rich fibrin network. Cytokine concentrations are positively associated with platelet-rich fibrin microstructure and portion in a rabbit model. As platelet-rich fibrin is the main entity currently used in regenerative medicine, assessing cytokine concentration and the most valuable portion of PRF gels is essential and recommended to all physicians.
Stein-Merlob, Ashley F.; Kessinger, Chase W.; Erdem, S. Sibel; Zelada, Henry; Hilderbrand, Scott A.; Lin, Charles P.; Tearney, Guillermo J.; Jaff, Michael R.; Reed, Guy L.; Henke, Peter K.; McCarthy, Jason R.; Jaffer, Farouc A.
2015-01-01
Fibrinolytic therapy of venous thromboembolism (VTE) is increasingly utilized, yet limited knowledge is available regarding in vivo mechanisms that govern fibrinolytic efficacy. In particular, it is unknown how age-dependent thrombus organization limits direct blood contact with fibrin, the target of blood-based fibrinolytic agents. Utilizing high-resolution in vivo optical molecular imaging with FTP11, a near-infrared fluorescence (NIRF) fibrin-specific reporter, here we investigated the in vivo interrelationships of blood accessibility to fibrin, thrombus age, thrombus neoendothelialization, and fibrinolysis in murine venous thrombosis (VT). In both stasis VT and non-stasis VT, NIRF microscopy showed that FTP11 fibrin binding was thrombus age-dependent. FTP11 localized to the luminal surface of early-stage VT, but only minimally to subacute VT (p<0.001). Transmission electron microscopy of early stage VT revealed direct blood cell contact with luminal fibrin-rich surfaces. In contrast, subacute VT exhibited an encasing CD31+ neoendothelial layer that limited blood cell contact with thrombus fibrin in both VT models. Next we developed a theranostic strategy to predict fibrinolytic efficacy based on the in vivo fibrin accessibility to blood NIRF signal. Mice with variably aged VT underwent FTP11 injection and intravital microscopy (IVM), followed by tissue plasminogen activator infusion to induce VT fibrinolysis. Fibrin molecular IVM revealed that early stage VT, but not subacute VT, bound FTP11 (p<0.05), and experienced higher rates of fibrinolysis and total fibrinolysis (p<0.05 vs. subacute VT). Before fibrinolysis, the baseline FTP11 NIRF signal predicted the net fibrinolysis at 60 minutes (p<0.001). Taken together, these data provide novel insights into the temporal evolution of VT and its susceptibility to therapeutic fibrinolysis. Fibrin molecular imaging may provide a theranostic strategy to identify venous thrombi amenable to fibrinolytic therapies. PMID:26516370
Botnar, René M; Brangsch, Julia; Reimann, Carolin; Janssen, Christian H P; Razavi, Reza; Hamm, Bernd; Makowski, Marcus R
2018-05-30
The incidence of abdominal aortic aneurysms (AAAs) will significantly increase during the next decade. Novel biomarkers, besides diameter, are needed for a better characterization of aneurysms and the estimation of the risk of rupture. Fibrin is a key protein in the formation of focal hematoma associated with the dissection of the aortic wall and the development of larger thrombi during the progression of AAAs. This study evaluated the potential of a fibrin-specific magnetic resonance (MR) probe for the in vivo characterization of the different stages of AAAs. AAAs spontaneously developed in ApoE -/- mice following the infusion of angiotensin-II (Ang-II, 1 μg/kg -1 ·per minute). An established fibrin-specific molecular MR probe (EP2104R, 10 μmol/kg -1 ) was administered after 1 to 4 weeks following Ang-II infusion (n=8 per group). All imaging experiments were performed on a clinical 3T Achieva MR system with a microscopy coil (Philips Healthcare, Netherlands). The development of AAA-associated fibrin-rich hematoma and thrombi was assessed. The high signal generated by the fibrin probe enabled high-resolution MR imaging for an accurate assessment and quantification of the relative fibrin composition of focal hematoma and thrombi. Contrast-to-noise-ratios (CNRs) and R1-relaxation rates following the administration of the fibrin probe were in good agreement with ex vivo immunohistomorphometry ( R 2 =0.83 and 0.85) and gadolinium concentrations determined by inductively coupled plasma mass spectroscopy ( R 2 =0.78 and 0.72). The fibrin-specific molecular MR probe allowed the delineation and quantification of changes in fibrin content in early and advanced AAAs. Fibrin MRI could provide a novel in vivo biomarker to improve the risk stratification of patients with aortic aneurysms. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Biggerstaff, J; Amirkhosravi, A; Francis, J L
1997-10-01
Fibrin forms part of the stroma essential for growth of solid tumors. Anticoagulants reduce primary tumor growth and tumor metastasis in murine and some human tumors. These effects may be partly mediated by reduction of intra-tumor fibrin, although there are no quantitative data to support this hypothesis. We therefore evaluated the effect of warfarin on fibrin deposition in a subcutaneously (s.c.) implanted murine tumor using confocal laser scanning microscopy (CLSM). AJ mice received no treatment (n = 6) or sodium warfarin (3.5 mg/L in drinking water, n = 5). All animals received 2 x 10(6) syngeneic Neuro2a neuroblastoma cells s.c. After 14 days, primary tumors were excised and placed in liquid nitrogen. Warfarin treatment resulted in a small, but significant (P < 0.05), decrease in wet tumor weight. Frozen sections (20 microns) were incubated with goat anti-mouse fibrin(ogen) or normal goat serum (isotypic control) and stained with FITC-conjugated rabbit anti-goat antibody. Using a Multiprobe 2001 CLSM (Molecular Dynamics, Sunnyvale, CA), 20 serial optical sections were taken from five, randomly chosen, high power fields (60x objective) for each slide. A threshold excluded all fluorescence except that from structural components within the tumor stroma (fibrin). The volume of fibrin in each section series was determined, and the percentage of tumor volume occupied by fibrin calculated. Intra- and inter-assay variation were assessed on serial frozen tumor sections from an untreated animal. The percentage fibrin volume was not significantly different among or within experiments, indicating that the procedure was reproducible. In controls, the median (range) volume occupied by fibrin was 8.1% (2.4-22.3%), whereas in anticoagulated animals, this was reduced to 3.7% (0.4-14.0%; P < 0.001). This is the first quantitative demonstration that warfarin reduces fibrin deposition in solid tumors. We conclude that three-dimensional CLSM is useful for the quantitation of tissue antigens and that the technique may have clinical value.
Platelet glycoprotein VI binds to polymerized fibrin and promotes thrombin generation.
Mammadova-Bach, Elmina; Ollivier, Véronique; Loyau, Stéphane; Schaff, Mathieu; Dumont, Bénédicte; Favier, Rémi; Freyburger, Geneviève; Latger-Cannard, Véronique; Nieswandt, Bernhard; Gachet, Christian; Mangin, Pierre H; Jandrot-Perrus, Martine
2015-07-30
Fibrin, the coagulation end product, consolidates the platelet plug at sites of vascular injury and supports the recruitment of circulating platelets. In addition to integrin αIIbβ3, another as-yet-unidentified receptor is thought to mediate platelet interaction with fibrin. Platelet glycoprotein VI (GPVI) interacts with collagen and several other adhesive macromolecules. We evaluated the hypothesis that GPVI could be a functional platelet receptor for fibrin. Calibrated thrombin assays using platelet-rich plasma (PRP) showed that tissue factor-triggered thrombin generation was impaired in GPVI-deficient patients and reduced by the anti-GPVI Fab 9O12. Assays on reconstituted PRP and PRP from fibrinogen-deficient patients revealed a fibrinogen-dependent enhancement of thrombin generation, which relied on functional GPVI. The effect of GPVI was found to depend on fibrin polymerization. A binding assay showed a specific interaction between GPVI-Fc and fibrin, inhibited by the Fab 9O12. This Fab also reduced platelet adhesion to fibrin at low (300 s(-1)) and high (1500 s(-1)) wall shear rates. Platelets adherent to fibrin displayed shape change, exposure of procoagulant phospholipids, and the formation of small clots. When hirudinated blood was perfused at 1500 s(-1) over preformed fibrin-rich clots, the Fab 9O12 decreased the recruitment of platelets by up to 85%. This study identifies GPVI as a platelet receptor for polymerized fibrin with 2 major functions: (1) amplification of thrombin generation and (2) recruitment of circulating platelets to clots. These so-far-unrecognized properties of GPVI confer on it a key role in thrombus growth and stabilization. © 2015 by The American Society of Hematology.
Bagó, Juli R.; Pegna, Guillaume J.; Okolie, Onyi; Hingtgen, Shawn D.
2016-01-01
Tumor-homing cytotoxic stem cell (SC) therapy is a promising new approach for treating the incurable brain cancer glioblastoma (GBM). However, problems of retaining cytotoxic SCs within the post-surgical GBM resection cavity are likely to significantly limit the clinical utility of this strategy. Here, we describe a new fibrin-based transplant approach capable of increasing cytotoxic SC retention and persistence within the resection cavity, yet remaining permissive to tumoritropic migration. This fibrin-based transplant can effectively treat both solid and post-surgical human GBM in mice. Using our murine model of image-guided model of GBM resection, we discovered that suspending human mesenchymal stem cells (hMSCS) in a fibrin matrix increased initial retention in the surgical resection cavity 2-fold and prolonged persistence in the cavity 3-fold compared to conventional delivery strategies. Time-lapse motion analysis revealed that cytotoxic hMSCs in the fibrin matrix remain tumoritropic, rapidly migrating from the fibrin matrix to co-localize with cultured human GBM cells. We encapsulated hMSCs releasing the cytotoxic agent TRAIL (hMSC-sTR) in fibrin, and found hMSC-sTR/fibrin therapy reduced the viability of multiple 3-D human GBM spheroids and regressed established human GBM xenografts 3-fold in 11 days. Mimicking clinical therapy of surgically resected GBM, intra-cavity seeding of therapeutic hMSC-sTR encapsulated in fibrin reduced post-surgical GBM volumes 6-fold, increased time to recurrence 4-fold, and prolonged median survival from 15 to 36 days compared to control-treated animals. Fibrin-based SC therapy could represent a clinically compatible, viable treatment to suppress recurrence of post-surgical GBM and other lethal cancer types. PMID:26803410
Cole, Heather A.; Ohba, Tetsuro; Nyman, Jeffry S.; Hirotaka, Haro; Cates, Justin M. M.; Flick, Matthew J.; Degen, Jay L.; Schoenecker, Jonathan G.
2015-01-01
Objective Osteoporosis is a skeletal disorder characterized by low bone mass and increased bone fragility associated with aging, menopause, smoking, obesity, or diabetes. Persistent inflammation has been identified as an instigating factor in progressive bone loss. In addition to the role of fibrin in coagulation, inordinate fibrin deposition within a tissue matrix results in increased local inflammation. Given that fibrin accumulation is a hallmark of osteoporosis-related co-morbidities, we undertook this study to test the hypothesis that persistent fibrin deposition causes inflammatory osteoporosis. Methods Multiple imaging modalities, bone integrity metrics, and histologic analyses were employed to evaluate skeletal derangements in relation to fibrin deposition, circulating fibrinogen levels, and systemic markers of inflammation in mice that were plasminogen deficient and in plasminogen-deficient mice that were concomitantly either fibrinogen deficient or carrying a mutant form of fibrinogen lacking the αMβ2 binding motif. Results Mice generated with a genetic deficit in the key fibrinolytic protease, plasmin, uniformly developed severe osteoporosis. Furthermore, the development of osteoporosis was fibrin(ogen) dependent, and the derangements in the bone remodeling unit were mechanistically tied to fibrin(ogen)-mediated activation of osteoclasts via activation of the leukocyte integrin receptor αMβ2 on monocytes and secondary stimulation of osteoblasts by RANKL. Notably, the genetic elimination of fibrin(ogen) or the expression of a mutant form of fibrinogen retaining clotting function but lacking the αMβ2 binding motif prevented the degenerative skeletal phenotypes, resulting in normal local and systemic cytokine levels. Conclusion Taken together, these data reveal for the first time that fibrin promotes inflammation-driven systemic osteoporosis, which suggests a novel association between hemostasis, inflammation, and bone biology. PMID:24664548
Alves, Christina S.; Konstantopoulos, Konstantinos
2012-01-01
Fibrin(ogen) mediates sustained tumor cell adhesion and survival in the pulmonary vasculature, thereby facilitating the metastatic dissemination of tumor cells. CD44 is the major functional fibrin receptor on colon carcinoma cells. Growth factors, such as platelet-derived growth factor (PDGF), induce post-translational protein modifications, which modulate ligand binding activity. In view of the roles of PDGF, fibrin(ogen) and CD44 in cancer metastasis, we aimed to delineate the effect of PDGF on CD44-fibrin recognition. By immunoprecipitating CD44 from PDGF-treated and untreated LS174T colon carcinoma cells, which express primarily CD44v, we demonstrate that PDGF enhances the adhesion of CD44v-coated beads to immobilized fibrin. Enzymatic inhibition studies coupled with flow-based adhesion assays and autoradiography reveal that PDGF augments the binding of CD44v to fibrin by significantly attenuating the extent of CD44 sulfation primarily on chondroitin and dermatan sulfate chains. Surface plasmon resonance assays confirm that PDGF enhances the affinity of CD44v-fibrin binding by markedly reducing its dissociation rate while modestly increasing the association rate. PDGF mildly reduces the affinity of CD44v-hyaluronan binding without affecting selectin-CD44v recognition. The latter is attributed to the fact that CD44v binds to selectins via sialofucosylated O-linked residues independent of heparan, dermatan and chondroitin sulfates. Interestingly, PDGF moderately reduces the sulfation of CD44s and CD44s-fibrin recognition. Collectively, these data offer a novel perspective into the mechanism by which PGDF regulates CD44-dependent binding of metastatic colon carcinoma cells to fibrin(ogen). PMID:23056168
Arulmoli, Janahan; Wright, Heather J.; Phan, Duc T.T.; Sheth, Urmi; Que, Richard A.; Botten, Giovanni A.; Keating, Mark; Botvinick, Elliot L.; Pathak, Medha M.; Zarembinski, Thomas I.; Yanni, Daniel S.; Razorenova, Olga V.; Hughes, Christopher C.W.; Flanagan, Lisa A.
2017-01-01
Human neural stem/progenitor cells (hNSPCs) are good candidates for treating central nervous system (CNS) trauma since they secrete beneficial trophic factors and differentiate into mature CNS cells; however, many cells die after transplantation. This cell death can be ameliorated by inclusion of a biomaterial scaffold, making identification of optimal scaffolds for hNSPCs a critical research focus. We investigated the properties of fibrin-based scaffolds and their effects on hNSPCs and found that fibrin generated from salmon fibrinogen and thrombin stimulates greater hNSPC proliferation than mammalian fibrin. Fibrin scaffolds degrade over the course of a few days in vivo, so we sought to develop a novel scaffold that would retain the beneficial properties of fibrin but degrade more slowly to provide longer support for hNSPCs. We found combination scaffolds of salmon fibrin with interpenetrating networks (IPNs) of hyaluronic acid (HA) with and without laminin polymerize more effectively than fibrin alone and generate compliant hydrogels matching the physical properties of brain tissue. Furthermore, combination scaffolds support hNSPC proliferation and differentiation while significantly attenuating the cell-mediated degradation seen with fibrin alone. HNSPCs express two fibrinogen-binding integrins, αVβ1 and α5β1, and several laminin binding integrins (α7β1, α6β1, α3β1) that can mediate interaction with the scaffold. Lastly, to test the ability of scaffolds to support vascularization, we analyzed human cord blood-derived endothelial cells alone and in co-culture with hNSPCs and found enhanced vessel formation and complexity in co-cultures within combination scaffolds. Overall, combination scaffolds of fibrin, HA, and laminin are excellent biomaterials for hNSPCs. PMID:27475528
Cole, Heather A; Ohba, Tetsuro; Nyman, Jeffry S; Hirotaka, Haro; Cates, Justin M M; Flick, Matthew J; Degen, Jay L; Schoenecker, Jonathan G
2014-08-01
Osteoporosis is a skeletal disorder characterized by low bone mass and increased bone fragility associated with aging, menopause, smoking, obesity, or diabetes. Persistent inflammation has been identified as an instigating factor in progressive bone loss. In addition to the role of fibrin in coagulation, inordinate fibrin deposition within a tissue matrix results in increased local inflammation. Given that fibrin accumulation is a hallmark of osteoporosis-related comorbidities, we undertook this study to test the hypothesis that persistent fibrin deposition causes inflammatory osteoporosis. Multiple imaging modalities, bone integrity metrics, and histologic analyses were employed to evaluate skeletal derangements in relation to fibrin deposition, circulating fibrinogen levels, and systemic markers of inflammation in mice that were plasminogen deficient and in plasminogen-deficient mice that were concomitantly either fibrinogen deficient or carrying a mutant form of fibrinogen lacking the αM β2 binding motif. Mice generated with a genetic deficit in the key fibrinolytic protease, plasmin, uniformly developed severe osteoporosis. Furthermore, the development of osteoporosis was fibrin(ogen) dependent, and the derangements in the bone remodeling unit were mechanistically tied to fibrin(ogen)-mediated activation of osteoclasts via activation of the leukocyte integrin receptor αM β2 on monocytes and secondary stimulation of osteoblasts by RANKL. Notably, the genetic elimination of fibrin(ogen) or the expression of a mutant form of fibrinogen retaining clotting function but lacking the αM β2 binding motif prevented the degenerative skeletal phenotypes, resulting in normal local and systemic cytokine levels. Taken together, these data reveal for the first time that fibrin promotes inflammation-driven systemic osteoporosis, which suggests a novel association between hemostasis, inflammation, and bone biology. Copyright © 2014 by the American College of Rheumatology.
ART restorations and sealants placed in Chinese school children--results after three years.
Holmgren, C J; Lo, E C; Hu, D; Wan, H
2000-08-01
These were to assess whether ART restorations and sealants could be provided to children in a school environment in China, to assess patient acceptability of the ART approach, and to evaluate on a longitudinal basis the treatments performed. This study was conducted in Deyang, Sichuan Province, in western China. A total of 294 ART restorations were placed in 197 children and 191 fissure sealants were placed in 140 children by five middle-level dentists in four secondary schools. Standard instruments and procedures for ART were used. The restorative material used was a high-strength glass-ionomer (Ketac-Molar, ESPE). The treatments were evaluated annually after placement by the same examiner who had not been involved in the placement of the restorations nor sealants using explorers and mouth-mirrors. At the 3-year examination an independent external examiner evaluated the restorations using USPHS criteria. Most of the children did not report discomfort during treatment and 92% were willing to receive ART restorations again. The cumulative 1-year and 3-year survival rates of small Class I restorations were 99% and 92% respectively. The corresponding figures for large Class I restorations were 90% and 77%. After 3 years, 72% of the sealants were either partially or completely retained. Only 2% of the sealed teeth developed fissure caries and these involved teeth where the sealants had been lost. Similar success rates were found using USPHS criteria. The ART approach for preventing and treating tooth decay in Chinese school children was shown to be appropriate, effective and acceptable. The 3-year survival rates of the restorations were high but were related to the size and type of the restoration.
Effect of enamel sealants on tooth bleaching and on the color stability of the result.
Corcodel, N; Hassel, A J; Sen, S; Saure, D; Rammelsberg, P; Lux, C J; Zingler, S
2017-04-01
The purpose of this in vitro study was to evaluate the effect of enamel sealants on bleaching of natural teeth by use of 40 % hydrogen peroxide in a dental surgery. The color stability of the results from bleaching was, furthermore, determined 10 months after the bleaching procedure. In a standardized setting, four sealants (Pro Seal ® , Light Bond™ Sealant, Protecto ® , and Clinpro™ XT Varnish) were applied to and removed from human teeth in accordance with the manufacturer's instructions. Natural teeth served as medium; half of the teeth were sealed and the others served as controls. Hydrogen peroxide gel (40 %; Opalescence Boost; Ultradent Products, South Jordan, UT, USA) was used as bleaching agent. Color measurement was performed with a spectroradiometer (Photoresearch PR670) before the bleaching process (T1) and 24 h (T2) and 10 months (T3) after bleaching. The spectroradiometer results were expressed by use of the Commission Internationale de l'Éclairage (CIE) L*a*b* color notation. The L*, a*, and b* values of the sealed and the unsealed surfaces were not significantly different at any time during the study (p > 0.05), irrespective of the sealant used. Ten months after the bleaching process, mean L*, a*, and b* values were lower than at 1-day post-bleaching; the mean value of ΔE between 1-day post-bleaching and 10 months post-bleaching was 2.46 (±3.1). The results of the study suggest that the effectiveness of professional tooth whitening is not appreciably affected by the application of the four sealants tested.
Shafiei, Fereshteh; Zarean, Mehran; Razmjoei, Faranak
2018-01-01
Background The effectiveness of sealants is dependent upon their adhesion to enamel surface. The aim of the study was to evaluate the sealing ability of a pit and fissure sealant used with a universal adhesive (etch-and-rinse vs. self-etch modes) when the site is contaminated with saliva. Adhesive properties were evaluated as microleakage and scanning electron microscopic (SEM) characteristics. Material and Methods A total of 72 mandibular third molars were randomly divided into 6 groups (n=12). Occlusal pits and fissures were sealed with an unfilled resin fissure sealant (FS) material with or without saliva contamination. The groups included: 1) phosphoric acid etching + FS (control), 2) phosphoric acid etching + Scotchbond Universal (etch-and-rinse) + FS, 3) phosphoric acid etching + saliva + Scotchbond Universal (etch-and-rinse) + FS, 4) Scotchbond Universal (self-etching) + FS,5) Scotchbond Universal (self-etching) + saliva + FS, and 6) Scotchbond Universal (self-etching) + saliva + Scotchbond Universal + FS. After thermocycling, the teeth were placed in 0.5% fuchsin, sectioned, and evaluated by digital microscopy. Two samples from each group were also observed by SEM. The data were analyzed with Kruskal-Wallis and Mann-Whitney tests for a significance of p<0.05. Results There were significant differences among groups. Groups 1,2 and 4 showed the least microleakage, with no significant differences among groups. Saliva contamination led to increased microleakage and gap formation in SEM images in groups 3, 5 and 6. Conclusions The fissure sealing ability of the universal adhesive in etch-and-rinse or self-etch modes was similar to that of conventional acid etching. Saliva contamination had a negative effect on sealant adhesion to pretreated enamel. Key words:Pit and fissure sealant, Universal adhesive, Saliva. PMID:29670708
Crane, Judy L
2014-02-01
High concentrations of polycyclic aromatic hydrocarbons (PAHs) are accumulating in many urban stormwater ponds in Minnesota, resulting in either expensive disposal of the excavated sediment or deferred maintenance by economically challenged municipalities. Fifteen stormwater ponds in the Minneapolis-St. Paul, MN, metropolitan area were studied to determine sources of PAHs to bed sediments through the application of several environmental forensic techniques, including a contaminant mass balance receptor model. The model results were quite robust and indicated that coal tar-based sealant (CT-sealant) particulate washoff and dust sources were the most important sources of PAHs (67.1%), followed by vehicle-related sources (29.5%), and pine wood combustion particles (3.4%). The distribution of 34 parent and alkylated PAHs was also evaluated regarding ancillary measurements of black carbon, total organic carbon, and particle size classes. None of these parameters were significantly different based on major land-use classifications (i.e., residential, commercial, and industrial) for pond watersheds. PAH contamination in three stormwater ponds was high enough to present a risk to benthic invertebrates, whereas nine ponds exceeded human health risk-based benchmarks that would prompt more expensive disposal of dredged sediment. The State of Minnesota has been addressing the broader issue of PAH-contaminated stormwater ponds by encouraging local municipalities to ban CT-sealants (29 in all) and to promote pollution prevention alternatives to businesses and homeowners, such as switching to asphalt-based sealants. A statewide CT-sealant ban was recently enacted. Other local and regional jurisdictions may benefit from using Minnesota's approach where CT-sealants are still used.
Subclinical and clinical mastitis in heifers following the use of a teat sealant precalving.
Parker, K I; Compton, C; Anniss, F M; Weir, A; Heuer, C; McDougall, S
2007-01-01
This study investigated the effect in heifers of infusion of a bismuth subnitrate teat-canal sealant and bacterial intramammary infection (IMI) precalving on prevalence of postcalving IMI and incidence of clinical mastitis in the first 2 wk postcalving. Glands (n = 1,020) from heifers (n = 255) in 5 seasonally calving, pasture-fed dairy herds were randomly assigned within heifer to 1 of 4 treatment groups (no treatment; mammary gland secretion collection; infusion of a teat sealant; or sample collection with infusion of teat sealant). Heifers within a herd were enrolled on one calendar day, 31 d on average before the planned start of the seasonal calving period. Duplicate milk samples were collected from each gland within 4 d after calving for bacterial culture. Herd owners collected duplicate milk samples, before treatment, for bacterial culture from glands they defined as having clinical mastitis. The gland prevalence of IMI precalving was 15.5% and did not differ between herds. Bacteria isolated precalving included coagulase-negative staphylococci (76.9% of all bacteriologically positive samples), Streptococcus uberis (14.1%), Staphylococcus aureus (5.1%), Corynebacterium spp. (3.8%), and others (0.1%). The presence of an IMI precalving increased the risk of an IMI postcalving 3.6-fold and the risk of clinical mastitis 4-fold, relative to no IMI precalving. Infusion of the teat sealant reduced the risk of postcalving IMI due to Strep. uberis by 84%, and of clinical mastitis by 68%. Sampling the glands precalving had no effect on postcalving IMI or on clinical mastitis incidence. Use of an internal teat canal sealant in heifers precalving may be a useful tool for reducing the risk of subclinical and clinical mastitis in heifers.
Survival of atraumatic restorative treatment (ART) sealants and restorations: a meta-analysis.
de Amorim, Rodrigo G; Leal, Soraya C; Frencken, Jo E
2012-04-01
The purpose of this study is to perform a systematic investigation plus meta-analysis into survival of atraumatic restorative treatment (ART) sealants and restorations using high-viscosity glass ionomers and to compare the results with those from the 2005 ART meta-analysis. Until February 2010, four databases were searched. Two hundred four publications were found, and 66 reported on ART restorations or sealant survival. Based on five exclusion criteria, two independent reviewers selected the 29 publications that accounted for the meta-analysis. Confidence intervals (CI) and or standard errors were calculated and the heterogeneity variance of the survival rates was estimated. Location (school/clinic) was an independent variable. The survival rates of single-surface and multiple-surface ART restorations in primary teeth over the first 2 years were 93% (CI, 91-94%) and 62% (CI, 51-73%), respectively; for single-surface ART restorations in permanent teeth over the first 3 and 5 years it was 85% (CI, 77-91%) and 80% (CI, 76-83%), respectively and for multiple-surface ART restorations in permanent teeth over 1 year it was 86% (CI, 59-98%). The mean annual dentine lesion incidence rate, in pits and fissures previously sealed using ART, over the first 3 years was 1%. No location effect and no differences between the 2005 and 2010 survival rates of ART restorations and sealants were observed. The short-term survival rates of single-surface ART restorations in primary and permanent teeth, and the caries-preventive effect of ART sealants were high. ART can safely be used in single-surface cavities in both primary and permanent teeth. ART sealants have a high caries preventive effect.
Memarpour, Mahtab; Shafiei, Fereshteh; Zarean, Mehran; Razmjoei, Faranak
2018-01-01
The effectiveness of sealants is dependent upon their adhesion to enamel surface. The aim of the study was to evaluate the sealing ability of a pit and fissure sealant used with a universal adhesive (etch-and-rinse vs. self-etch modes) when the site is contaminated with saliva. Adhesive properties were evaluated as microleakage and scanning electron microscopic (SEM) characteristics. A total of 72 mandibular third molars were randomly divided into 6 groups (n=12). Occlusal pits and fissures were sealed with an unfilled resin fissure sealant (FS) material with or without saliva contamination. The groups included: 1) phosphoric acid etching + FS (control), 2) phosphoric acid etching + Scotchbond Universal (etch-and-rinse) + FS, 3) phosphoric acid etching + saliva + Scotchbond Universal (etch-and-rinse) + FS, 4) Scotchbond Universal (self-etching) + FS,5) Scotchbond Universal (self-etching) + saliva + FS, and 6) Scotchbond Universal (self-etching) + saliva + Scotchbond Universal + FS. After thermocycling, the teeth were placed in 0.5% fuchsin, sectioned, and evaluated by digital microscopy. Two samples from each group were also observed by SEM. The data were analyzed with Kruskal-Wallis and Mann-Whitney tests for a significance of p <0.05. There were significant differences among groups. Groups 1,2 and 4 showed the least microleakage, with no significant differences among groups. Saliva contamination led to increased microleakage and gap formation in SEM images in groups 3, 5 and 6. The fissure sealing ability of the universal adhesive in etch-and-rinse or self-etch modes was similar to that of conventional acid etching. Saliva contamination had a negative effect on sealant adhesion to pretreated enamel. Key words: Pit and fissure sealant, Universal adhesive, Saliva.
Hepdeniz, Ozge Kam; Temel, Ugur Burak; Ugurlu, Muhittin; Koskan, Ozgur
2016-01-01
Objective: Microleakage is still one of the most cited reasons for failure of resin composite restorations. Alternative methods to prevent microleakage have been investigated increasingly. The aim of this study is to evaluate the microleakage in Class V resin composite restorations with or without application of surface sealants with different filler content. Materials and Methods: Ninety-six cavities were prepared on the buccal and lingual surfaces with the coronal margins located in enamel and the cervical margins located in dentin. The cavities restored with an adhesive system (Clearfil SE Bond, Kuraray, Tokyo, Japan) and resin composite (Clearfil Majesty ES-2, Kuraray, Tokyo, Japan). Teeth were stored in distilled water for 24 h and separated into four groups according to the surface sealants (Control, Fortify, Fortify Plus, and G-Coat Plus). The teeth were thermocycled (500 cycles, 5–55° C), immersed in basic fuchsine, sectioned, and analyzed for dye penetration using stereomicroscope. The data were submitted to statistical analysis by Kruskal–Wallis and Bonferroni–Dunn test. Results: The results of the study indicated that there was minimum leakage at the enamel margins of all groups. Bonferroni–Dunn tests revealed that Fortify and GC-Coat groups showed significantly less leakage than the Control group and the Fortify Plus group at dentin margins in lingual surfaces (P < 0.05). Conclusion: The all surface sealants used in this study eliminated microleakage at enamel margins. Moreover, unfilled or nanofilled surface sealants were the most effective in decreasing the degree of marginal microleakage at dentin margins. However, viscosity and penetrability of the sealants could be considered for sealing ability besides composition. PMID:27095890
NASA Astrophysics Data System (ADS)
Goodman, H.
2017-12-01
This investigation seeks to develop sealant technology that can restore containment to completed wells that suffer CO2 gas leakages currently untreatable using conventional technologies. Experimentation is performed at the Mont Terri Underground Research Laboratory (MT-URL) located in NW Switzerland. The laboratory affords investigators an intermediate-scale test site that bridges the gap between the laboratory bench and full field-scale conditions. Project focus is the development of CO2 leakage remediation capability using sealant technology. The experimental concept includes design and installation of a field scale completion package designed to mimic well systems heating-cooling conditions that may result in the development of micro-annuli detachments between the casing-cement-formation boundaries (Figure 1). Of particular interest is to test novel sealants that can be injected in to relatively narrow micro-annuli flow-paths of less than 120 microns aperture. Per a special report on CO2 storage submitted to the IPCC[1], active injection wells, along with inactive wells that have been abandoned, are identified as one of the most probable sources of leakage pathways for CO2 escape to the surface. Origins of pressure leakage common to injection well and completions architecture often occur due to tensile cracking from temperature cycles, micro-annulus by casing contraction (differential casing to cement sheath movement) and cement sheath channel development. This discussion summarizes the experiment capability and sealant testing results. The experiment concludes with overcoring of the entire mock-completion test site to assess sealant performance in 2018. [1] IPCC Special Report on Carbon Dioxide Capture and Storage (September 2005), section 5.7.2 Processes and pathways for release of CO2 from geological storage sites, page 244
Brown, Ashley C.; Barker, Thomas H.
2013-01-01
Fibrinogen is one of the primary components of the coagulation cascade and rapidly forms an insoluble matrix following tissue injury. In addition to its important role in hemostasis, fibrin acts as a scaffold for tissue repair and provides important cues for directing cell phenotype following injury. Because of these properties and the ease of polymerization of the material, fibrin has been widely utilized as a biomaterial for over a century. Modifying the macroscopic properties of fibrin, such as elasticity and porosity, has been somewhat elusive until recently, yet with a molecular-level rational design approach can now be somewhat easily modified through alterations of molecular interactions key to the protein’s polymerization process. This review outlines the biochemistry of fibrin and discusses methods for modification of molecular interactions and their application to fibrin based biomaterials. PMID:24056097
Plasminogen fragments K 1-3 and K 5 bind to different sites in fibrin fragment DD.
Grinenko, T V; Kapustianenko, L G; Yatsenko, T A; Yusova, O I; Rybachuk, V N
2016-01-01
Specific plasminogen-binding sites of fibrin molecule are located in Аα148-160 regions of C-terminal domains. Plasminogen interaction with these sites initiates the activation process of proenzyme and subsequent fibrin lysis. In this study we investigated the binding of plasminogen fragments K 1-3 and K 5 with fibrin fragment DD and their effect on Glu-plasminogen interaction with DD. It was shown that the level of Glu-plasminogen binding to fibrin fragment DD is decreased by 50-60% in the presence of K 1-3 and K 5. Fragments K 1-3 and K 5 have high affinity to fibrin fragment DD (Kd is 0.02 for K 1-3 and 0.054 μМ for K 5). K 5 interaction is independent and K 1-3 is partly dependent on C-terminal lysine residues. K 1-3 interacts with complex of fragment DD-immobilized K 5 as well as K 5 with complex of fragment DD-immobilized K 1-3. The plasminogen fragments do not displace each other from binding sites located in fibrin fragment DD, but can compete for the interaction. The results indicate that fibrin fragment DD contains different binding sites for plasminogen kringle fragments K 1-3 and K 5, which can be located close to each other. The role of amino acid residues of fibrin molecule Аα148-160 region in interaction with fragments K 1-3 and K 5 is discussed.
Niwa, Kazuki; Mimuro, Jun; Miyata, Masaaki; Sugo, Teruko; Ohmori, Tsukasa; Madoiwa, Seiji; Tei, Chuwa; Sakata, Yoichi
2008-01-01
Emerging lines of evidence have suggested that certain dysfibrinogens present a significant risk of thrombosis. The thrombophilic nature of a new-type of dysfibrinogen Kagoshima identified in a 36-year-old female with deep vein thrombosis during the postpartum period was studied. Based on the analyses of the patient fibrinogen and the fibrinogen genes, fibrinogen Kagoshima was shown to have the amino acid substitution of gammaThr-314 to Ile that resulted in impaired function and hypofibrinogenemia. Polymerization of fibrin monomers derived from patient fibrinogen was severely impaired with a partial correction in the presence of calcium ions, causing very low clottability and delayed cross-linking of patient fibrin catalyzed by activated factor XIII. Because of the low clottability, a large amount of soluble fibrin was formed upon thrombin treatment, resulting in an increase of thrombin in the soluble fraction. Additionally, tPA-mediated plasmin generation on fibrin was impaired and calcium-ion-dependent integrity of the gamma-chain D domain of Kagoshima fibrinogen was perturbed. The presence of many tapered-fiber ends inside the tangled fibrin networks, observed by scanning electron microscopy, suggested early termination of fibrin polymerization and the structural alteration. These data suggest that fibrinogen Kagoshima is dysfunctional, giving rise to formation of fibrinolysis-resistant soluble fibrin polymers and entrance of soluble fibrin associating with thrombin to the circulation, partly accounting for the thrombophilic nature of the affected fibrinogen and fibrin molecules.
Comparison of Fibrin Glue and Sutures for Conjunctival Wound Closure in Strabismus Surgery
Lee, Jae Hyung
2011-01-01
Purpose To evaluate and compare the efficacy and tolerance of fibrin glue and sutures for closing conjunctival wounds in strabismus surgery. Methods In a prospective trial, we performed strabismus surgery using limbal incisions. Conjunctival wounds were closed with fibrin glue in 20 eyes of 20 patients (fibrin group) and 8-0 polyglactin suture in 20 eyes of 20 patients (suture group). Postoperative pain, tearing, and inflammation were compared at 1 day, 1 week, 3 weeks, and 6 weeks after surgery. Conjunctival incision healing was also investigated. Results One day and one week post-operatively, pain and tearing scores were lower in the fibrin group (p = 0.000, respectively). Mean surgery time was significantly shorter in the fibrin (48 ± 5 minutes) than the suture group (63 ± 7 minutes) (p = 0.000). Inflammation was significantly more severe in the suture group until 3 weeks postoperative (p = 0.000, respectively), but conjunctival healing did not differ between the groups. Hyperemia appeared more prominent in the fibrin group 3 and 6 weeks after surgery (p = 0.087 and 0.000, respectively). Two eyes in the fibrin group showed conjunctival gaps of more than 2 mm, which closed spontaneously by three weeks after surgery. No allergic reactions or infections developed. Conclusions Fibrin glue proved to be as effective as sutures in closing conjunctival wounds. It provides more comfortable early postoperative courses and might be considered as an alternative to sutures in strabismus surgery. PMID:21655043
Brzoska, Tomasz; Suzuki, Yuko; Mogami, Hideo; Sano, Hideto; Urano, Tetsumei
2013-01-01
Recently, by employing intra-vital confocal microscopy, we demonstrated that platelets expose phosphatidylserine (PS) and fibrin accumulate only in the center of the thrombus but not in its periphery. To address the question how exposure of platelet anionic phospholipids is regulated within the thrombus, an in-vitro experiment using diluted platelet-rich plasma was employed, in which the fibrin network was formed in the presence of platelets, and PS exposure on the platelet surface was analyzed using Confocal Laser Scanning Microscopy. Almost all platelets exposed PS after treatment with tissue factor, thrombin or ionomycin. Argatroban abrogated fibrin network formation in all samples, however, platelet PS exposure was inhibited only in tissue factor- and thrombin-treated samples but not in ionomycin-treated samples. FK633, an α(IIb)β₃ antagonist, and cytochalasin B impaired platelet binding to the fibrin scaffold and significantly reduced PS exposure evoked by thrombin. Gly-Pro-Arg-Pro amide abrogated not only fibrin network formation, but also PS exposure on platelets without suppressing platelet binding to fibrin/fibrinogen. These results suggest that outside-in signals in platelets generated by their binding to the rigid fibrin network are essential for PS exposure after thrombin treatment.
Brzoska, Tomasz; Suzuki, Yuko; Mogami, Hideo; Sano, Hideto; Urano, Tetsumei
2013-01-01
Recently, by employing intra-vital confocal microscopy, we demonstrated that platelets expose phosphatidylserine (PS) and fibrin accumulate only in the center of the thrombus but not in its periphery. To address the question how exposure of platelet anionic phospholipids is regulated within the thrombus, an in-vitro experiment using diluted platelet-rich plasma was employed, in which the fibrin network was formed in the presence of platelets, and PS exposure on the platelet surface was analyzed using Confocal Laser Scanning Microscopy. Almost all platelets exposed PS after treatment with tissue factor, thrombin or ionomycin. Argatroban abrogated fibrin network formation in all samples, however, platelet PS exposure was inhibited only in tissue factor- and thrombin-treated samples but not in ionomycin-treated samples. FK633, an αIIbβ3 antagonist, and cytochalasin B impaired platelet binding to the fibrin scaffold and significantly reduced PS exposure evoked by thrombin. Gly-Pro-Arg-Pro amide abrogated not only fibrin network formation, but also PS exposure on platelets without suppressing platelet binding to fibrin/fibrinogen. These results suggest that outside-in signals in platelets generated by their binding to the rigid fibrin network are essential for PS exposure after thrombin treatment. PMID:23383331
Lytic resistance of fibrin containing red blood cells
Wohner, Nikolett; Sótonyi, Péter; Machovich, Raymund; Szabó, László; Tenekedjiev, Kiril; Silva, Marta M.C.G.; Longstaff, Colin; Kolev, Krasimir
2012-01-01
Objective Arterial thrombi contain variable amounts of red blood cell (RBC), which interact with fibrinogen through an eptifibatide-sensitive receptor and modify the structure of fibrin. Here we evaluate the modulator role of RBCs in the lytic susceptibility of fibrin. Methods and Results If fibrin is formed at increasing RBC counts, scanning electron microscopy evidenced a decrease in fiber diameter from 150 nm to 96 nm at 40 %(v/v) RBC, an effect susceptible to eptifibatide inhibition (restoring 140 nm diameter). RBC prolonged the lysis time in a homogeneous-phase fibrinolytic assay with tissue plasminogen activator (tPA) by up to 22.7±1.6 %, but not in the presence of eptifibatide. Confocal laser microscopy using green fluorescent protein (GFP)-labeled tPA and orange fluorescent fibrin showed that 20-40 %(v/v) RBC significantly slowed down the dissolution of the clots. tPA-GFP did not accumulate on the surface of fibrin containing RBC at any cell count above 10 %. The presence of RBC in the clot suppressed the tPA-induced plasminogen activation resulting in a 45 % less plasmin generated after 30 min activation at 40 %(v/v) RBC. Conclusion RBCs confer lytic resistance to fibrin resulting from modified fibrin structure and impaired plasminogen activation through a mechanism that involves eptifibatide-sensitive fibrinogen-RBC interactions. PMID:21737785
Silva, Raúl F; Carmona, Jorge U; Rezende, Cleuza M F
2013-04-15
The aim of this study was to use transmission electron microscopy to describe the ultrastructural characteristics of clots obtained from canine and feline platelet concentrates (PC) that had been activated with calcium gluconate (CG) or CG plus batroxobin (CGB). Platelets from fibrin clots were classified according their morphological changes. The area of the intercellular space (μm2), the area of the fibrin fibers (μm2), and the width of the fibrin fibers (μm) were determined for the dog clots. The platelet area (μm2), the area of fibrin fibers (μm2), the ratio of the minor and major axes of platelets, the ratio of the major and minor axes of platelets, and the number of α-granules found within platelets were measured for the cat clots. Cat platelets displayed full activation. Dog platelets displayed lysis with loss of normal architecture. In both species, a statistically significant difference was found (P < 0.01) between the fibrin fiber measurements in the PC clots activated with CG and CGB. The findings suggest that activation with CG caused platelet alpha granules to release their contents. In cats, fibrin production was greater when the PC was activated with CG. In dogs, activation with CG produced thick fibrin fibers.
Ma, Kun; Titan, Ashley L.; Stafford, Melissa; Zheng, Chun hua; Levenston, Marc E.
2012-01-01
Fibrin and alginate hydrogels have been widely used to support chondrogenesis of bone marrow-derived mesenchymal stem cells (BM-MSCs) for articular cartilage and fibrocartilage tissue engineering, with distinct advantages and disadvantages to each material. Attempting to produce a gel scaffold exhibiting beneficial characteristics of both materials, we fabricated fibrin/alginate blended hydrogels at various blend ratios and evaluated the gel morphology, mechanical properties and their support for BM-MSC chondrogenesis. Results show that when the fibrin/alginate ratio decreased, the fibrin architecture transitioned from uniform to interconnected fibrous and finally to disconnected islands against an alginate background, with opposing trends in the alginate architecture. Fibrin maintained gel extensibility and promoted cell proliferation, while alginate improved the gel biostability and better supported glycosaminoglycan and collagen II production and chondrogenic gene expression. Blended gels had physical and biological characteristics intermediate between fibrin and alginate. Of the blends examined, FA 40:8 (40 mg/mL fibrinogen blended with 8 mg/mL alginate) was found to be the most appropriate group for future studies on tension-driven BM-MSC fibrochondrogenesis. As BM-MSC differentiation appeared to vary between fibrin and alginate regions of blended scaffolds, this study also highlighted the potential to develop spatially heterogeneous tissues through manipulating the heterogeneity of scaffold composition. PMID:22750738
INVESTIGATION OF THE POTENTIAL ANTIMICROBIAL EFFICACY OF SEALANTS USED IN HVAC SYSTEMS
The paper gives results of an investigation of the potential antimicrobial efficacy of sealants used in heating, ventilation and air-conditioning systems. Recent experiments confirm field experience that duct cleaning alone may not provide adequate protection from regrowth of fu...
Kaufman, Arthur; Werth, John
1986-01-01
A bipolar gas reactant distribution assembly for use in a fuel cell is disclosed, the assembly having a solid edge seal to prevent leakage of gaseous reactants wherein a pair of porous plates are provided with peripheral slits generally parallel to, and spaced apart from two edges of the plate, the slit being filled with a solid, fusible, gas impervious edge sealing compound. The plates are assembled with opposite faces adjacent one another with a layer of a fusible sealant material therebetween the slits in the individual plates being approximately perpendicular to one another. The plates are bonded to each other by the simultaneous application of heat and pressure to cause a redistribution of the sealant into the pores of the adjacent plate surfaces and to cause the edge sealing compound to flow and impregnate the region of the plates adjacent the slits and comingle with the sealant layer material to form a continuous layer of sealant along the edges of the assembled plates.
Measuring quality of dental care: Caries prevention services for children.
Herndon, Jill Boylston; Tomar, Scott L; Catalanotto, Frank A; Rudner, Nancy; Huang, I-Chan; Aravamudhan, Krishna; Shenkman, Elizabeth A; Crall, James J
2015-08-01
The authors conducted a study to validate the following 3 evidence-based, process-of-care quality measures focused on dental caries prevention for children with an elevated risk of experiencing caries: sealants for 6- to 9-year-olds, sealants for 10- to 14-year-olds, and topical fluoride. Using evidence-based guidelines, the Dental Quality Alliance developed measures for implementation with administrative data at the plan and program levels. To validate the measures, the authors used data from the Florida and Texas Medicaid programs and Children's Health Insurance Programs and from national commercial dental benefit plans. Data were extracted from 414 randomly selected dental office records to validate the use of administrative data to accurately calculate the measures. The authors also assessed statistically significant variations in overall measure performance. Agreement between administrative data and dental records was 95% for sealants (κ = 0.82) and 90% for topical fluoride (κ = 0.78). Sensitivity and specificity were 90.7% and 88.5% for topical fluoride and 77.8% and 98.8% for sealants, respectively. Variation in overall measure performance was greatest for topical fluoride (χ(2) = 5,887.1; P < .01); 18% to 37% of children with an elevated risk of experiencing caries received at least 2 topical fluoride applications during the reporting year. Although there was greater variation in performance for sealants for 6- to 9-year-olds (range, 21.0-31.3%; χ(2) = 548.6; P < .01) compared with sealants for 10- to 14-year-olds (range, 8.4-11.1%; χ(2) = 22.7; P < .01), overall sealant placement rates were lower for 10- to 14-year-olds. These evidence-based, caries prevention process-of-care quality measures can be implemented feasibly and validly using administrative claims data. The measures can be used to assess, monitor, and improve the proportion of children with an elevated risk of experiencing dental caries who receive evidence-based caries prevention services. Copyright © 2015 American Dental Association. Published by Elsevier Inc. All rights reserved.
Nakamura, T
1992-07-01
The possibility of repairing the defect of the pars interarticularis (pars defect) with Bone Morphogenetic Protein (BMP) and fibrin glue was studied. The pars defect established in the 5th lumbar vertebra of Wistar rat was treated with surgical implantation of a composite consisting of BMP, fibrin glue and autologous cancellous bone. At 3, 6, 9 and 12 weeks after implantation, the osteoinductive activity in the pars defect was observed histologically and compared with that of other composite implants such as BMP with fibrin glue, autologous cancellous bone alone and autologous cancellous bone with fibrin glue. Although perfect bone fusion was not obtained with any of the composites employed, a significant increase in bone formation was seen in a composite of BMP, fibrin glue and autologous cancellous bone (p less than 0.01) as compared with that seen in the others. Consequently, implantation of BMP and fibrin glue combined with some biomaterials which support osteo-induction of BMP and stabilize the pars defect might be successfully applied to repair the pars defect.
ELECTROMAGNETICALLY INDUCED DISTORTION OF A FIBRIN MATRIX WITH EMBEDDED MICROPARTICLES
SCOGIN, TYLER; YESUDASAN, SUMITH; WALKER, MITCHELL L. R.
2018-01-01
Blood clots occur in the human body when they are required to prevent bleeding. In pathological states such as diabetes and sickle cell disease, blood clots can also form undesirably due to hypercoagulable plasma conditions. With the continued effort in developing fibrin therapies for potential life-saving solutions, more mechanical modeling is needed to understand the properties of fibrin structures with inclusions. In this study, a fibrin matrix embedded with magnetic micro particles (MMPs) was subjected to a magnetic field to determine the magnitude of the required force to create plastic deformation within the fibrin clot. Using finite element (FE) analysis, we estimated the magnetic force from an electromagnet at a sample space located approximately 3 cm away from the coil center. This electromagnetic force coupled with gravity was applied on a fibrin mechanical system with MMPs to calculate the stresses and displacements. Using appropriate coil parameters, it was determined that application of a magnetic field of 730 A/m on the fibrin surface was necessary to achieve an electromagnetic force of 36 nN (to engender plastic deformation). PMID:29628543
Submillisecond elastic recoil reveals molecular origins of fibrin fiber mechanics.
Hudson, Nathan E; Ding, Feng; Bucay, Igal; O'Brien, E Timothy; Gorkun, Oleg V; Superfine, Richard; Lord, Susan T; Dokholyan, Nikolay V; Falvo, Michael R
2013-06-18
Fibrin fibers form the structural scaffold of blood clots. Thus, their mechanical properties are of central importance to understanding hemostasis and thrombotic disease. Recent studies have revealed that fibrin fibers are elastomeric despite their high degree of molecular ordering. These results have inspired a variety of molecular models for fibrin's elasticity, ranging from reversible protein unfolding to rubber-like elasticity. An important property that has not been explored is the timescale of elastic recoil, a parameter that is critical for fibrin's mechanical function and places a temporal constraint on molecular models of fiber elasticity. Using high-frame-rate imaging and atomic force microscopy-based nanomanipulation, we measured the recoil dynamics of individual fibrin fibers and found that the recoil was orders of magnitude faster than anticipated from models involving protein refolding. We also performed steered discrete molecular-dynamics simulations to investigate the molecular origins of the observed recoil. Our results point to the unstructured αC regions of the otherwise structured fibrin molecule as being responsible for the elastic recoil of the fibers. Copyright © 2013 Biophysical Society. Published by Elsevier Inc. All rights reserved.
2016-03-07
This final rule revises the benefit payment provision for nonparticipating providers to more closely mirror industry practices by requiring TDP nonparticipating providers to be reimbursed (minus the appropriate cost-share) at the lesser of billed charges or the network maximum allowable charge for similar services in that same locality (region) or state. This rule also updates the regulatory provisions regarding dental sealants to clearly categorize them as a preventive service and, consequently, eliminate the current 20 percent cost-share applicable to sealants to conform with the language in the regulation to the statute.
DOT National Transportation Integrated Search
2009-01-01
This report summarizes research presented in separate technical reports, papers, and journal articles that collectively document the development of a systematic process to aid in the selection of appropriate bituminous hot-poured sealants for pavemen...
78 FR 76984 - Airworthiness Directives; Eurocopter France Helicopters
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-20
... inspecting each jettisonable emergency exit window panel (window) for sealant, and removing any sealant that exists in the window's extruded sections. This AD was prompted by jettison tests during routine maintenance inspections that showed the windows failed to jettison. The actions of this AD are intended to...
78 FR 37156 - Airworthiness Directives; Eurocopter France Helicopters
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-20
... inspecting each jettisonable emergency exit window panel (window) for sealant, and removing any sealant that exists in the window's extruded sections. This proposed AD is prompted by jettison tests during routine maintenance inspections that showed the windows failed to jettison. The proposed actions are intended to...
Dental Pit and Fissure Sealants: Implications for School Health Personnel.
ERIC Educational Resources Information Center
McCormack-Brown, K. R.; And Others
1989-01-01
To promote good personal hygiene practices in students, school health personnel must be informed about dental pit and fissure sealants and related programs. Adoption and maintenance of such programs may depend on the success of school health personnel in educating administrators and policymakers. (SM)
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-26
... Promulgation of Air Quality Implementation Plans; Pennsylvania; Adhesives and Sealants Rule AGENCY... Implementation Plan (SIP) revision submitted by the Commonwealth of Pennsylvania. The SIP revision pertains to... volatile organic compounds (VOC) from the manufacture, sale, use, or application of adhesives, sealants...
Clinical experience with fibrin glue in cardiac surgery.
Köveker, G; de Vivie, E R; Hellberg, K D
1981-10-01
Cardiac surgery is often associated with hemostatic abnormalities leading to severe bleeding. Special problems are to be expected, if prosthetic material has to be implanted. Preclotting of Dacron prostheses with blood is well established but failures are sometimes encountered. Several years ago a new hemostatic sealing system (fibrin glue) was introduced into therapy. Since 1978 fibrin glue has been applied in 176 patients. The indications were: 1. sealing of woven Dacron prostheses, 2. bleeding from suture-holes (Gore-Tex), 3. diffuse myocardial bleeding and 4. prevention of kinking of coronary artery grafts. In 32 patients with an aortoventriculoplasty operation using Dacron the "blood preclotting" and "fibrin sealing" methods were compared. In the fibrin glue group there was a significant reduction in postoperative blood loss as well as a shortening of the operation time (period of protamin administration to skin closure). No fibrinolytic dissolution of the fibrin layer on the prostheses was observed.
Fibrin Clots Are Equilibrium Polymers That Can Be Remodeled Without Proteolytic Digestion
NASA Astrophysics Data System (ADS)
Chernysh, Irina N.; Nagaswami, Chandrasekaran; Purohit, Prashant K.; Weisel, John W.
2012-11-01
Fibrin polymerization is a necessary part of hemostasis but clots can obstruct blood vessels and cause heart attacks and strokes. The polymerization reactions are specific and controlled, involving strong knob-into-hole interactions to convert soluble fibrinogen into insoluble fibrin. It has long been assumed that clots and thrombi are stable structures until proteolytic digestion. On the contrary, using the technique of fluorescence recovery after photobleaching, we demonstrate here that there is turnover of fibrin in an uncrosslinked clot. A peptide representing the knobs involved in fibrin polymerization can compete for the holes and dissolve a preformed fibrin clot, or increase the fraction of soluble oligomers, with striking rearrangements in clot structure. These results imply that in vivo clots or thrombi are more dynamic structures than previously believed that may be remodeled as a result of local environmental conditions, may account for some embolization, and suggest a target for therapeutic intervention.
Eshghpour, Majid; Majidi, Mohamad Reza; Nejat, Amir Hossein
2012-01-01
Introduction: The healing process after surgery is a challenging issue for surgeons. Various materials and techniques have been developed to facilitate this process and reduce its period. Fibrin adhesives are often used in cardiothoracic and vascular surgery to seal diffuse microvascular bleeding and in general and plastic surgery to seal wound borders. This Case report and literature review will introduce the various usages of platelet-rich fibrin in different surgical procedures and the method of producing the matrix. Case Report: A 24-year old man with periorbital skin avulsion treated with PRF membrane has been reported and discussed in this paper. Conclusion: Platelet-rich fibrin is a natural autologous fibrin matrix, which can be produced with a simple blood sample and a table centrifuge. The material has been used in a wide range of surgical procedures to shorten the healing period and reduce post-surgical complications. PMID:24303410
2014-01-01
Background Autologous transplantation of modified mesenchymal stem cells (MSCs) is a promising candidate for the treatment of the refractory clinical disease, avascular necrosis of the femoral head (ANFH). Our previous attempts by compounding MSCs with medical fibrin glue to treat ANFH in animal model have achieved excellent effects. However, the underlying molecular mechanism is unclear, especially on the transgenic gene expression. Methods Rabbit MSCs were isolated and compounded with fibrin glue. Following degrading of fibrin glue, proliferation, viability, expression of transgenic hepatocyte growth factor gene as well as osteogenic differentiation of MSCs were evaluated together with that of uncompounded MSCs. Fibrin glue-compounded MSCs were transplanted into the lesion of ANFH model, and the therapeutic efficacy was compared with uncompounded MSCs. One-Way ANOVA was used to determine the statistical significance among treatment groups. Results Fibrin glue compounding will not affect molecular activities of MSCs, including hepatocyte growth factor (HGF) secretion, cell proliferation and viability, and osteogenic differentiation in vitro. When applying fibrin glue-compounded MSCs for the therapy of ANFH in vivo, fibrin glue functioned as a drug delivery system and provided a sustaining microenvironment for MSCs which helped the relatively long-term secretion of HGF in the femoral head lesion and resulted in improved therapeutic efficacy when compared with uncompounded MSCs as indicated by hematoxylin-eosin staining and immunohistochemistry of osteocalcin, CD105 and HGF. Conclusion Transplantation of fibrin glue-compounding MSCs is a promising novel method for ANFH therapy. PMID:24885252
Erfanian, Reza; Firouzi, Masoumeh; Nabian, Mohammad Hossein; Darvishzadeh, Masoud; Zanjani, Leila Oryadi; Zadegan, Shayan Abdollah; Kamrani, Reza Shahryar
2014-01-01
The use of fibrin adhesives has a broad background in nerve repair. Currently the suboptimal physical properties of single- donor fibrin adhesives have restricted their usage. The present experiment studies the performance and physical characteristics of a modified fibrin glue prepared from single-donor human plasma in the repair of posterior tibial nerve of rat. Forty Wistar rats were divided into 5 groups; in the control group, tibial nerve was completely transected and no treatment was done, while in the four experimental groups the nerve stumps were reconnected by one suture, three sutures, one suture with fibrin glue and fibrin glue alone respectively. During 8 weeks of follow-up, Tibial Function Index was measured weekly and adhesive strength, inflammation and scar formation were assessed at the end of the study. Nerve stumps dehiscence rate and adhesive strength were similar in all experimental groups and significantly differed from control group (P<0.05). By the end of the eighth follow-up week, functional recovery of one and three sutures groups were significantly higher than groups in which fibrin glue was used for repair (P<0.05). The amount of inflammation and scar tissue formation was similar among all groups. The study results show that the prepared single-donor fibrin adhesive has acceptable mechanical properties which could provide required adhesiveness and hold nerve stumps in the long term; yet, we acknowledge that more studies are needed to improve functional outcome of single donor fibrin adhesive repair.
Fibrin adhesive is better than sutures in pterygium surgery.
Ratnalingam, Vanitha; Eu, Andrew Lim Keat; Ng, Gim Leong; Taharin, Rohana; John, Elizabeth
2010-05-01
To evaluate the recurrence rate, surgical time, and postoperative pain between conjunctival autografting with sutures and with fibrin adhesive in pterygium surgery. A prospective, randomized, double-blind, clinical trial on the benefits of using fibrin adhesive in place of sutures in pterygium surgery. One hundred seventy-five eyes with primary pterygium were randomized to undergo pterygium surgery with conjunctival autograft transplantation using either fibrin adhesive or sutures. One hundred thirty-seven eyes of 113 patients that were operated on by a single surgeon (V.R.) completed the 1-year follow-up. Sixty-eight eyes were operated with fibrin adhesive and 69 eyes with sutures. Patients were followed up at 1 day, 1 week, 1 month, 6 months, and 1 year after surgery. Pterygium recurrence and postoperative pain was graded by an independent observer (A.L.) masked to the method of treatment. Surgical time was measured with a stopwatch. All patients were followed up for 1 year. There were 3 recurrences (4.41%) in the fibrin adhesive group and 11 recurrences (15.9%) in the suture group. The mean duration required to complete surgery in the fibrin adhesive group was 16.93 +/- 2.85 minutes, whereas that of the suture group was 29.84 +/- 5.65 minutes, which was statistically significant (P < 0.001). The immediate postoperative pain score and week 1 postoperative pain score were significantly lower in the fibrin adhesive group (P < 0.05). No major complications were observed in either group. The use of fibrin adhesive in primary pterygium surgery with conjunctival autografts reduces the recurrence rate, surgical time, and postoperative pain when compared with sutures.
Soleimannejad, Mostafa; Ebrahimi-Barough, Somayeh; Soleimani, Masoud; Nadri, Samad; Tavangar, Seyed Mohammad; Roohipoor, Ramak; Yazdankhah, Meysam; Bayat, Neda; Riazi-Esfahani, Mohammad; Ai, Jafar
2018-06-01
Stem cell-based therapies are attraction approaches for regenerative medicine for treating retinal diseases. One of the limitations in cell therapy is cell death following post-injection whit preventing functional integration with retinal tissue. Fibrin gel, a bio-polymeric material with excellent biocompatibility, provides numerous advantages as a tissue engineering scaffold and a stem cell carrier. Therefore, current research is focusing on developing fibrin hydrogel scaffolds to protect stem cells during delivery and to stimulate endogenous regeneration through interactions of transplanted stem cells and retinal tissue. In this study fibrin gel was used as hydrogel scaffold for immobilization of cells. The structural characteristics of fibrin gel scaffold were examined with SEM. Rheological properties of fibrin gel were measured by rheometer and biodegradation rate of fibrin were assayed for 2 weeks. After isolation of stem cells CJMSCs, the cells were differentiated into photoreceptor-like cells by exposing with taurin for 14 days in tissue culture plate (TCP group) and fibrin hydrogel (3 D group). The attachment of cells was analyzed with SEM and MTT. The expression of rhodopsin, PKC, CRX, recoverin, peripherin, nestin and RPE65 as photoreceptor-like cell markers was evaluated by immunocytochemistry and quantitative real-time PCR (RT-PCR) in TCP and 3 D groups. The results of SEM analysis showed CJMSCs were well attached in fibrin gels and there were good integrity between cells and scaffold. The elastic modulus and constant degradation of the gel contributes to the growth and proliferation of cells. There was no toxicity effect of fibrin hydrogel on cells and the viability of cultured cells was higher in 3 D fibrin gels in comparison with TCP groups. After 2 weeks, the expression of rhodopsin, PKC, CRX, peripherin, recoverin, nestin and RPE65 as special markers of photoreceptor cells were detected by Real time PCR and immunofluorescence that these expressions in 3 D groups were higher than TCP groups. In conclusion, our findings showed that application of readily available sources of adult stem cells like human conjunctiva stem cells encapsulated in fibrin gel could be interesting strategy to enhance photoreceptor progenitor cell numbers for repair and regeneration of retina disease such as photoreceptor injury.
Code of Federal Regulations, 2011 CFR
2011-07-01
... performance test. 2. Carbon adsorber (regenerative) to which puncture sealant application spray booth emissions are ducted a. Maintain the total regeneration mass, volumetric flow, and carbon bed temperature at the operating range established during the performance test.b. Reestablish the carbon bed temperature...
Copolymer sealant compositions and method for making
NASA Technical Reports Server (NTRS)
Singh, Navjot (Inventor); Leman, John Thomas (Inventor); Whitney, John M. (Inventor); Krabbenhoft, Herman Otto (Inventor)
2002-01-01
Condensation curable poly(fluoroorgano)siloxane-poly(silarylene)siloxane block copolymer compositions having a glass transition temperature not exceeding about -54.degree. C. and excellent solvent resistance have been found useful as sealants. Polyalkoxysilylorgano compounds, such as 1,4-bis[trimethoxysilyl(ethyl)]benzene have been found to be effective as cross-linkers.
Copolymer sealant compositions and method for making
NASA Technical Reports Server (NTRS)
Singh, Navjot (Inventor); Leman, John Thomas (Inventor); Whitney, John M. (Inventor); Krabbenhoft, Herman Otto (Inventor)
2004-01-01
Condensation curable poly(fluoroorgano)siloxane-poly(silarylene)siloxane block copolymer compositions having a glass transition temperature not exceeding about -54.degree. C. and excellent solvent resistance have been found useful as sealants. Polyalkoxysilylorgano compounds, such as 1,4-bis[trimethoxysilyl(ethyl)]benzene have been found to be effective as cross-linkers.
Copolymer sealant compositions and method for making
NASA Technical Reports Server (NTRS)
Singh, Navjot (Inventor); Leman, John Thomas (Inventor); Whitney, John M. (Inventor); Krabbenhoft, Herman Otto (Inventor)
2003-01-01
Condensation curable poly(fluoroorgano)siloxane-poly(silarylene)siloxane block copolymer compositions having a glass transition temperature not exceeding about -54.degree. C. and excellent solvent resistance have been found useful as sealants. Polyalkoxysilylorgano compounds, such as 1,4-bis[trimethoxysilyl(ethyl)]benzene have been found to be effective as cross-linkers.
The article gives results of an evaluation of the potential efficacy of an antimicrobial-containing sealant on fibrous-glass duct liner (FGDL) and galvanized steel (GS) as used in heating, ventilating, and air-conditioning (HVAC) systems. HVAC systems become dirty to various degr...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-22
..., ``Prevention of Air Pollution From Adhesives, Sealants, Adhesive Primers and Sealant Primers,'' and Subchapter... revisions to Subchapter 23, ``Prevention of Air Pollution From Architectural Coatings,'' Subchapter 24, ``Prevention of Air Pollution From Consumer Products,'' and Subchapter 25, ``Control and Prohibition of Air...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-31
... coatings, paper and related products, building seals and sealants, plastics, plumbing, roofing, and... products, building seals and sealants, plastics, plumbing, roofing, and mattresses. The purpose of this... plumbing laboratories are also accredited for plastic and paint testing in support of plumbing testing...
Zhao, Wenxue; Han, Qianqian; Lin, Hang; Gao, Yuan; Sun, Wenjie; Zhao, Yannan; Wang, Bin; Chen, Bing; Xiao, Zhifeng; Dai, Jianwu
2008-10-01
Targeted therapy is a new generation of therapeutics, where two critical factors are involved. One is the particular molecular target, and the other is the specific target-binding drug. In this work, the fibrin, a main component of plasma clot at wound sites, was used as the target for human bFGF, aiming to improve therapeutic neovascularization and wound repair. To endow bFGF with fibrin-targeting ability, a fibrin-binding peptide Kringle1 (K1), derived from human plasminogen, was fused to human bFGF. The recombinant K1bFGF showed high fibrin and plasma-clot-binding ability. When applied to the wound sites with plasma clots, K1bFGF induced robust neovascularization and improved wound healing. To extend the application of K1bFGF to other cases where no plasma clots exist, we developed a fibrin-scaffold/K1bFGF system. This system could induce localized neovascularization by delivery of K1bFGF in a sustained and site-targeting manner, and provide a microenvironment promoting cell growth and tissue regeneration. In summary, we successfully used the pathologic environment fibrin clot as the target for bFGF, and based on which bFGF was designed into a targeting agent by introduction of a fibrin-binding peptide. This provides a potential approach to improve therapeutic neovascularization and wound repair.
Reconstruction of living bilayer human skin equivalent utilizing human fibrin as a scaffold.
Mazlyzam, A L; Aminuddin, B S; Fuzina, N H; Norhayati, M M; Fauziah, O; Isa, M R; Saim, L; Ruszymah, B H I
2007-05-01
Our aim of this study was to develop a new methodology for constructing a bilayer human skin equivalent to create a more clinical compliance skin graft composite for the treatment of various skin defects. We utilized human plasma derived fibrin as the scaffold for the development of a living bilayer human skin equivalent: fibrin-fibroblast and fibrin-keratinocyte (B-FF/FK SE). Skin cells from six consented patients were culture-expanded to passage 1. For B-FF/FK SE formation, human fibroblasts were embedded in human fibrin matrix and subsequently another layer of human keratinocytes in human fibrin matrix was stacked on top. The B-FF/FK SE was then transplanted to athymic mice model for 4 weeks to evaluate its regeneration and clinical performance. The in vivo B-FF/FK SE has similar properties as native human skin by histological analysis and expression of basal Keratin 14 gene in the epidermal layer and Collagen type I gene in the dermal layer. Electron microscopy analysis of in vivo B-FF/FK SE showed well-formed and continuous epidermal-dermal junction. We have successfully developed a technique to engineer living bilayer human skin equivalent using human fibrin matrix. The utilization of culture-expanded human skin cells and fibrin matrix from human blood will allow a fully autologous human skin equivalent construction.
Yang, Kai-Chiang; Wang, Chun-Hao; Chang, Hao-Hueng; Chan, Wing P; Chi, Chau-Hwa; Kuo, Tzong-Fu
2012-11-01
Odontogenesis is a complex process with a series of epithelial-mesenchymal interactions and odontogenic molecular cascades. In tissue engineering of teeth from stem cells, platelet-rich fibrin (PRF), which is rich in growth factors and cytokines, may improve regeneration. Accordingly, PRF was added into fibrin glue to enrich the microenvironment with growth factors. Unerupted second molar tooth buds were harvested from miniature swine and cultured in vitro for 3 weeks to obtain dental bud cells (DBCs). Whole blood was collected for the preparation of PRF and fibrin glue before surgery. DBCs were suspended in fibrin glue and then enclosed with PRF, and the DBC-fibrin glue-PRF composite was autografted back into the original alveolar sockets. Radiographic and histological examinations were used to identify the regenerated tooth structure 36 weeks after implantation. Immunohistochemical staining was used to detect proteins specific to tooth regeneration. One pig developed a complete tooth with crown, root, pulp, enamel, dentin, odontoblast, cementum, blood vessels, and periodontal ligaments in indiscriminate shape. Another animal had an unerupted tooth that expressed cytokeratin 14, dentin matrix protein-1, vascular endothelial growth factor, and osteopontin. This study demonstrated, using autogenic cell transplantation in a porcine model, that DBCs seeded into fibrin glue-PRF could regenerate a complete tooth. Copyright © 2011 John Wiley & Sons, Ltd.
Chiti, Maria Costanza; Dolmans, Marie-Madeleine; Mortiaux, Lucie; Zhuge, Flanco; Ouni, Emna; Shahri, Parinaz Asiabi Kohneh; Van Ruymbeke, Evelyne; Champagne, Sophie-Demoustier; Donnez, Jacques; Amorim, Christiani Andrade
2018-01-01
The aim of this study is to optimize fibrin matrix composition in order to mimic human ovarian tissue architecture for human ovarian follicle encapsulation and grafting. Ultrastructure of fresh human ovarian cortex in age-related women (n = 3) and different fibrin formulations (F12.5/T1, F30/T50, F50/T50, F75/T75), rheology of fibrin matrices and histology of isolated and encapsulated human ovarian follicles in these matrices. Fresh human ovarian cortex showed a highly fibrous and structurally inhomogeneous architecture in three age-related patients, but the mean ± SD of fiber thickness (61.3 to 72.4 nm) was comparable between patients. When the fiber thickness of four different fibrin formulations was compared with human ovarian cortex, F50/T50 and F75/T75 showed similar fiber diameters to native tissue, while F12.5/T1 was significantly different (p value < 0.01). In addition, increased concentrations of fibrin exhibited enhanced storage modulus with F50/T50, resembling physiological ovarian rigidity. Excluding F12.5/T1 from further analysis, only three remaining fibrin matrices (F30/T50, F50/T50, F75/T75) were histologically investigated. For this, frozen-thawed fragments of human ovarian tissue collected from 22 patients were used to isolate ovarian follicles and encapsulate them in the three fibrin formulations. All three yielded similar follicle recovery and loss rates soon after encapsulation. Therefore, based on fiber thickness, porosity, and rigidity, we selected F50/T50 as the fibrin formulation that best mimics native tissue. Of all the different fibrin matrix concentrations tested, F50/T50 emerged as the combination of choice in terms of ultrastructure and rigidity, most closely resembling human ovarian cortex.
Cha, Dong Min; Kim, Kyeong Hwan; Choi, Hyuk Jin; Wee, Won Ryang
2012-01-01
Purpose To compare the effect of using fibrin glue or 10-0 nylon sutures on the clinical outcome of patients undergoing pterygium excision and conjunctival autografting. Methods We retrospectively reviewed the medical records of 52 eyes from 46 patients who underwent pterygium excision and conjunctival autografting and were followed up for more than 3 months. The operation duration, postoperative inflammation, complications, and recurrence rates were compared between groups of 20 patients (22 eyes) for whom fibrin glue was used (fibrin glue group) and 26 patients (30 eyes) for whom suturing was performed with 10-0 nylon (suture group) in pterygium excision and conjunctival autografting. Results The operation duration was 27.71 (5.22) minutes in the fibrin glue group and 43.30 (8.18) minutes in the suture group (p = 0.000). Seven days after the operation, the fibrin glue group showed milder conjunctival inflammation than the suture group (p = 0.000). Postoperative complications and corneal recurrence rates were not statistically different between the two groups. Conclusions The use of fibrin glue in pterygium excision with conjunctival autografting is likely to be a more effective, safer procedure than suturing. PMID:23204794
Identification of quantitative trait loci for fibrin clot phenotypes: The EuroCLOT study
Williams, Frances MK; Carter, Angela M; Kato, Bernet; Falchi, Mario; Bathum, Lise; Surdulescu, Gabriela; Kyvik, Kirsten Ohm; Palotie, Aarno; Spector, Tim D; Grant, Peter J
2012-01-01
Objectives Fibrin makes up the structural basis of an occlusive arterial thrombus and variability in fibrin phenotype relates to cardiovascular risk. The aims of the current study from the EU consortium EuroCLOT were to 1) determine the heritability of fibrin phenotypes and 2) identify QTLs associated with fibrin phenotypes. Methods 447 dizygotic (DZ) and 460 monozygotic (MZ) pairs of healthy UK Caucasian female twins and 199 DZ twin pairs from Denmark were studied. D-dimer, an indicator of fibrin turnover, was measured by ELISA and measures of clot formation, morphology and lysis were determined by turbidimetric assays. Heritability estimates and genome-wide linkage analysis were performed. Results Estimates of heritability for d-dimer and turbidometric variables were in the range 17 - 46%, with highest levels for maximal absorbance which provides an estimate of clot density. Genome-wide linkage analysis revealed 6 significant regions with LOD>3 on 5 chromosomes (5, 6, 9, 16 and 17). Conclusions The results indicate a significant genetic contribution to variability in fibrin phenotypes and highlight regions in the human genome which warrant further investigation in relation to ischaemic cardiovascular disorders and their therapy. PMID:19150881
Glottoplasty for male-to-female transsexualism: voice results.
Remacle, Marc; Matar, Nayla; Morsomme, Dominique; Veduyckt, Ingrid; Lawson, Georges
2011-01-01
The aim of this study was to evaluate the objective voice results of Wendler's glottoplasty in male-to-female transsexuals. We retrospectively reviewed our patients treated with Wendler's technique with minor modifications. Glottoplasty consisted in CO(2)-laser epithelial ablation of the anterior commissure and the two vocal folds in anterior third, suturing of the two vocal folds with two stitches of 3.0 resorbable thread, and application of fibrin sealant to strengthen the suture. Voice assessment was based mainly on fundamental frequency (F(0)), frequency range, jitter, maximum phonation time, phonation quotient, estimated subglottic pressure (ESGP) grade of dysphonia (G), and voice handicap index (VHI). These measures were taken before surgery and on the last follow-up visit. Our series included 15 patients with a mean age of 36 years. The mean follow-up period was 7.2 months. We did not observe any early complications related to the technique. The comparison between the preoperative and the postoperative measurements, using Wilcoxon signed rank test, showed a significant improvement of median F(0) from 139 to 191 Hz (P=0.006) with an increase in the grade of dysphonia (G(pre)=0.2, G(post)=1, P=0.013) and ESGP (ESGP(pre)=8.1 ± 3.2, ESGP(post)=12.0 ± 3.8, P=0.002). Other measurements, including VHI, did not show any significant differences pre- and postoperatively. Wendler's glottoplasty can contribute to feminize the voice. Copyright © 2011 The Voice Foundation. Published by Mosby, Inc. All rights reserved.
Determining ultra-low moisture permeation measurement for sealants on OLED encapsulation
NASA Astrophysics Data System (ADS)
Choi, Byung Il; Woo, Sang Bong; Kim, Jong Chul; Kim, Seung Hun; Seo, Sang Joon
2012-12-01
As the next-generation flexible display elements are very vulnerable to moisture, securing proper encapsulation is a decisive factor in enabling a long working life. Therefore, together with the recent development of plastic barrier films with very low permeabilities, interest in the permeabilities of sealants used for perimetric sealing has been increasing. In this study, equipment with a resolution of approximately ˜10-7 g·day-1 to measure moisture permeability in perimetric sealing was established, and the permeabilities of different sealants were measured. This equipment could have applications not only in the display industry but also in other sectors requiring encapsulation technology, such as the semiconductor and solar cell industries.
Safety and usability of hemostats, sealants, and adhesives.
Burks, Sandra; Spotnitz, William
2014-08-01
Hemostats, sealants, and adhesives are an integral part of surgical patient care. Nurses who have knowledge about these agents can better help ensure safe, efficient surgical patient care. As a caregiver and patient advocate, the perioperative nurse must understand the most current information about these agents and be prepared to facilitate the transfer of this knowledge to all caregivers. Information about these agents, including the contraindications, warnings, and precautions associated with their use as well as their preparation and application, is provided here. Algorithms designed to clarify the best options for using hemostats, sealants, and adhesives are included as well. Copyright © 2014 AORN, Inc. Published by Elsevier Inc. All rights reserved.
Multi-layer light-weight protective coating and method for application
NASA Technical Reports Server (NTRS)
Wiedemann, Karl E. (Inventor); Clark, Ronald K. (Inventor); Taylor, Patrick J. (Inventor)
1992-01-01
A thin, light-weight, multi-layer coating is provided for protecting metals and their alloys from environmental attack at high temperatures. A reaction barrier is applied to the metal substrate and a diffusion barrier is then applied to the reaction barrier. A sealant layer may also be applied to the diffusion barrier if desired. The reaction barrier is either non-reactive or passivating with respect to the metal substrate and the diffusion barrier. The diffusion barrier is either non-reactive or passivating with respect to the reaction barrier and the sealant layer. The sealant layer is immiscible with the diffusion barrier and has a softening point below the expected use temperature of the metal.
SPECT imaging of fibrin using fibrin-binding peptides.
Starmans, Lucas W E; van Duijnhoven, Sander M J; Rossin, Raffaella; Aime, Silvio; Daemen, Mat J A P; Nicolay, Klaas; Grüll, Holger
2013-01-01
Noninvasive detection of fibrin in vivo using diagnostic imaging modalities may improve clinical decision-making on possible therapeutic options in atherosclerosis, cancer and thrombus-related pathologies such as pulmonary embolism and deep venous thrombosis. The aim of this study was to assess the potential of a novel (111)In-labeled fibrin-binding peptide (FibPep) to visualize thrombi in mice noninvasively using single-photon emission computed tomography (SPECT). FibPep and a negative control peptide (NCFibPep) were synthesized and their fibrin-binding properties were assessed in vitro. FibPep showed enhanced binding compared with NCFibPep to both fibrin and blood clots. FibPep bound to fibrin with a dissociation constant (K(d)) of 0.8 μ m, whereas NCFibPep displayed at least a 100-fold lower affinity towards fibrin. A FeCl3 -injury carotid artery thrombosis mouse model was used to evaluate the peptides in vivo. FibPep and NCFibPep displayed rapid blood clearance and were eliminated via the renal pathway. In vivo SPECT imaging using FibPep allowed clear visualization of thrombi. Ex vivo biodistribution showed significantly increased uptake of FibPep in the thrombus-containing carotid in comparison to the noninjured carotid (5.7 ± 0.7 and 0.6 ± 0.4% injected dose per gram (%ID g(-1)), respectively; p < 0.01; n = 4), whereas nonspecific NCFibPep did not (0.4 ± 0.2 and 0.3 ± 0.0%ID g(-1), respectively; n = 4). In conclusion, FibPep displayed high affinity towards fibrin in vitro and rapid blood clearance in vivo, and allowed sensitive detection of thrombi using SPECT imaging. Therefore, this particular imaging approach may provide a new tool to diagnose and monitor diseases such as atherosclerosis and cancer. Copyright © 2013 John Wiley & Sons, Ltd.
Identification and characterization of α1 -antitrypsin in fibrin clots.
Talens, S; Malfliet, J J M C; van Hal, P Th W; Leebeek, F W G; Rijken, D C
2013-07-01
Preliminary studies indicated that α1 -antitrypsin (A1AT) is the most abundant protein that is non-covalently bound to fibrin clots prepared from plasma. The aim of this study was to identify and characterize fibrin(ogen)-bound A1AT. Plasma clots were prepared and extensively washed with saline. Clot-bound A1AT could only be extracted using denaturing agents such as urea, thiourea or SDS, pointing to an apparently strong association. Purified fibrinogen, but still containing A1AT as a contaminant, was gel filtered, which showed that the A1AT was bound to fibrinogen. A specific ELISA detected the presence of A1AT-fibrinogen complexes in both purified fibrinogen and pooled normal plasma. Finally, fibrin(ogen)-Sepharose chromatography indicated that A1AT purified from plasma contained a small fraction of fibrin(ogen)-binding A1AT. To study the inhibitory activity of fibrin(ogen)-bound A1AT, both fibrinogen containing A1AT and washed plasma clots were incubated with increasing amounts of elastase. SDS-PAGE and Western blotting showed under both conditions the generation of the A1AT-elastase complex as well as cleaved A1AT. The inhibitory activity of fibrin(ogen)-bound A1AT was also demonstrated by measuring elastase-induced lysis of fibrin clots. Fibrin clots contain strongly bound A1AT, which is functionally active as a serine protease inhibitor (serpin). This A1AT might play a role in the local regulation of proteases involved in coagulation or fibrinolysis and represent a novel link between the inflammatory and hemostatic systems. © 2013 International Society on Thrombosis and Haemostasis.
Brown, Ashley C.; Baker, Stephen; Douglas, Alison; Keating, Mark; Alvarez-Elizondo, Martha; Botvinick, Elliot; Guthold, Martin; Barker, Thomas H.
2015-01-01
Protein based polymers provide an exciting and complex landscape for tunable natural biomaterials through modulation of molecular level interactions. Here we demonstrate the ability to modify protein polymer structural and mechanical properties at multiple length scales by molecular ‘interference’ of fibrin’s native polymerization mechanism. We have previously reported that engagement of fibrin’s polymerization ‘hole b’, also known as ‘b-pockets’, through PEGylated complimentary ‘knob B’ mimics can increase fibrin network porosity but also, somewhat paradoxically, increase network stiffness. Here, we explore the possible mechanistic underpinning of this phenomenon through characterization of the effects of knob B-fibrin interaction at multiple length scales from molecular to bulk polymer. Despite its weak monovalent binding affinity for fibrin, addition of both knob B and PEGylated knob B at concentrations near the binding coefficient, Kd, increased fibrin network porosity, consistent with the reported role of knob B-hole b interactions in promoting lateral growth of fibrin fibers. Addition of PEGylated knob B decreases the extensibility of single fibrin fibers at concentrations near its Kd but increases extensibility of fibers at concentrations above its Kd. The data suggest this bimodal behavior is due to the individual contributions knob B, which decreases fiber extensibility, and PEG, which increase fiber extensibility. Taken together with laser trap-based microrheological and bulk rheological analyses of fibrin polymers, our data strongly suggests that hole b engagement increases in single fiber stiffness that translates to higher storage moduli of fibrin polymers despite their increased porosity. These data point to possible strategies for tuning fibrin polymer mechanical properties through modulation of single fiber mechanics. PMID:25725552
Fibrin glue inhibits migration of ocular surface epithelial cells
Yeung, A M; Faraj, L A; McIntosh, O D; Dhillon, V K; Dua, H S
2016-01-01
Purpose Fibrin glue has been used successfully in numerous ophthalmic surgical procedures. Recently, fibrin glue has been used in limbal stem cell transplantation to reduce both operative time and to negate the need for sutures. The aim of this study was to determine the effects of fibrin glue on epithelial cell migration in vitro. Methods Corneoscleral rims were split to retain the epithelial layer, Bowman's layer, and anterior stroma. Rims were cut into eight equal-sized pieces and were placed directly on culture plates or affixed with fibrin glue. Rims were maintained in culture for 25 days and epithelial cell growth was monitored. Cells were photographed to measure area or growth and immunofluorescence staining of explants for fibrin was performed. Results Explants that were glued demonstrated significantly delayed epithelial cell growth and migration as compared with explants without glue. By day 16, all fibrin glue had dissolved and coincided with onset of cell growth from glued explants. Cell growth commenced between days 3 and 4 for control explants without glue and around days 14–16 for explants with fibrin glue. Conclusions Fibrin glue delays epithelial cell migration by acting as a physical barrier and can potentially interfere with explant-derived limbal epithelial cell migration on to the corneal surface. We propose that glue should be used to attach the conjunctival frill of the limbal explant but care should be taken to ensure that the glue does not wrap around the explant if used to secure the explant as well. Strategic use of glue, to attach the recessed conjunctiva, can be advantageous in delaying conjunctival cell migration and reducing the need for sequential sector conjunctival epitheliectomy. PMID:27367746
Regulation of Plasminogen Activation on Cell Surfaces and Fibrin.
Urano, Tetsumei; Castellino, Francis J; Suzuki, Yuko
2018-05-20
The fibrinolytic system dissolves fibrin and maintains vascular patency. Recent advances in imaging analyses allowed visualization of the spatiotemporal regulatory mechanism of fibrinolysis, as well as its regulation by other plasma haemostasis cofactors. Vascular endothelial cells (VECs) retain tissue-type plasminogen activator (tPA) after secretion and maintain high plasminogen (plg) activation potential on their surfaces. As in plasma, the serpin, plasminogen activator inhibitor type 1 (PAI-1), regulates fibrinolytic potential via inhibition of the VEC surface-bound plg activator, tPA. Once fibrin is formed, plg activation by tPA is initiated and effectively amplified on the surface of fibrin, and fibrin is rapidly degraded. The specific binding of plg and tPA to lytic edges of partly degraded fibrin via newly generated C-terminal lysine residues, which amplifies fibrin digestion, is a central aspect of this pathophysiological mechanism. Thrombomodulin (TM) plays a role in the attenuation of the plg binding on fibrin and the associated fibrinolysis, which is reversed by a carboxypeptidase B inhibitor. This suggests that the plasma procarboxypeptidase B, thrombin activatable fibrinolysis inhibitor (TAFI), which is activated by thrombin bound to TM on VECs, is a critical aspect of the regulation of plg activation on VECs and subsequent fibrinolysis. Platelets also contain PAI-1, TAFI, TM and the fibrin crosslinking enzyme, Factor (F) XIIIa, and either secrete or expose these agents upon activation in order to regulate fibrinolysis. In this review, the native machinery of plg activation and fibrinolysis, as well as their spatiotemporal regulatory mechanisms, as revealed by imaging analyses, are discussed. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Spatiotemporal Characterization of a Fibrin Clot Using Quantitative Phase Imaging
Gannavarpu, Rajshekhar; Bhaduri, Basanta; Tangella, Krishnarao; Popescu, Gabriel
2014-01-01
Studying the dynamics of fibrin clot formation and its morphology is an important problem in biology and has significant impact for several scientific and clinical applications. We present a label-free technique based on quantitative phase imaging to address this problem. Using quantitative phase information, we characterized fibrin polymerization in real-time and present a mathematical model describing the transition from liquid to gel state. By exploiting the inherent optical sectioning capability of our instrument, we measured the three-dimensional structure of the fibrin clot. From this data, we evaluated the fractal nature of the fibrin network and extracted the fractal dimension. Our non-invasive and speckle-free approach analyzes the clotting process without the need for external contrast agents. PMID:25386701
A Synthetic Fibrin-Crosslinking Polymer for Modulating Clot Properties and Inducing Hemostasis
Chan, Leslie W.-G.; Wang, Xu; Wei, Hua; Pozzo, Lilo D.; White, Nathan J.; Pun, Suzie H.
2015-01-01
Clotting factor replacement is the standard management of acute bleeding in congenital and acquired bleeding disorders. We present a synthetic approach to hemostasis using an engineered hemostatic polymer (PolySTAT) that circulates innocuously in the blood, identifies sites of vascular injury, and promotes clot formation to stop bleeding. PolySTAT induces hemostasis by crosslinking the fibrin matrix within clots, mimicking the function of the transglutaminase Factor XIII. Furthermore, synthetic PolySTAT binds specifically to fibrin monomers and is uniformly integrated into fibrin fibers during fibrin polymerization, resulting in a fortified, hybrid polymer network with enhanced resistance to enzymatic degradation. In vivo hemostatic activity was confirmed in a rat model of trauma and fluid resuscitation in which intravenous administration of PolySTAT improved survival by reducing blood loss and resuscitation fluid requirements. PolySTAT-induced fibrin crosslinking is a novel approach to hemostasis utilizing synthetic polymers for non-invasive modulation of clot architecture with potentially wide-ranging therapeutic applications. PMID:25739763
The relationship to age and cerebral vascular accidents of fibrin and fibrinolytic activity
Hume, R.
1961-01-01
Three `normal' groups of people—young, middle-aged, and old—have been investigated with regard to the fibrin content and fibrinolytic activity of the blood. The fourth group consisted of middle-aged people who had previously sustained a cerebral vascular accident matched statistically for age with the middle-aged normals. It was concluded that fibrin increases with age but there is an interaction between age and sex, the female having a higher level in the young group and the male a higher level in the middle-aged group. There was no sex difference in the levels of fibrin in the old age group. Fibrinolytic activity increases with age and there is a positive correlation between fibrin and fibrinolytic activity but no age-sex interaction. Those with cerebral vascular accidents tended to have higher fibrin levels and lower fibrinolytic activity but the differences were not statistically significant. There did, however, appear to be an increase in antifibrinolytic activity in the cerebral vascular group. PMID:13716799
Fibrin glue as a protective tool for microanastomoses in limb reconstructive surgery.
Langer, Stefan; Schildhauer, Thomas A; Dudda, Marcel; Sauber, Jeannine; Spindler, Nick
2015-01-01
Fibrin glue becomes a more and more routinely used tool for stabilization of microanastomoses and nerve repair. This paper summarizes the technical properties and advantages of its use in a wide variety of microsurgical contexts, and includes an exemplary limb reconstructive case. A total of 131 patients who had undergone elective and emergency microsurgery mainly of the limbs were retrospectively analyzed, as was the use of free flaps. The use of fibrin glue allows for proper positioning of anastomoses and repaired nerves. No torsion of the pedicle could be seen. The flap survival rated >94%. The fibrin glue could stay in place in >99%. In the rare case of revision, the fibrin glue could easily be removed without damaging the region of the microanastomosis. Fibrin glue should not be used to repair insufficient, i.e., leaking anastomoses, but it does protect the site of anastomosis from tissue and fluid pressure. It prevents the pedickle from torsion and its use facilitates relocation of the microanastomoses in cases of revision surgery.
Evaluating cyclic fatigue of sealants during outdoor testing
R. Sam Williams; Steven Lacher; Corey Halpin; Christopher White
2009-01-01
A computer-controlled test apparatus (CCTA) and other instrumentation for subjecting sealant specimens to cyclic fatigue during outdoor exposure was developed. The CCTA enables us to use weather-induced conditions to cyclic fatigue specimens and to conduct controlled tests in-situ during the outdoor exposure. Thermally induced dimensional changes of an aluminum bar...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-22
... Division, U.S. Environmental Protection Agency, Region III, 1650 Arch Street, Philadelphia, Pennsylvania...--Adhesives and Sealants under Regulation 1141--Limiting Emissions of Volatile Organic Compounds from Consumer.... The revision is part of Delaware's strategy to achieve and maintain the 8- hour ozone national ambient...
NRMRL-RTP-P- 530a Foarde, K.K., VanOsdell, D.W., and Menetrez*, M.Y. Investigation of the Potential Antimicrobial Efficacy of Sealants Used in HVAC Systems. Published in: Journal of Air and Waste Management Association 51 (8):1219-1226 (2001). 07/06/2000 The paper gives result...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-13
....14(b), FTZ activity would be limited to the specific foreign-status materials and components and... housings; vertical auger tubes; chopper drive gearbox accessories; cotton picker frames and cabs; and, non... components and materials sourced from abroad include: sealant; sealant paste; oil drain assemblies; rubber...
An accelerated exposure and testing apparatus for building joint sealants
NASA Astrophysics Data System (ADS)
White, C. C.; Hunston, D. L.; Tan, K. T.; Hettenhouser, J.; Garver, J. D.
2013-09-01
The design, fabrication, and implementation of a computer-controlled exposure and testing apparatus for building joint sealants are described in this paper. This apparatus is unique in its ability to independently control and monitor temperature, relative humidity, ultraviolet (UV) radiation, and mechanical deformation. Each of these environmental factors can be controlled precisely over a wide range of conditions during periods of a month or more. Moreover, as controlled mechanical deformations can be generated, in situ mechanical characterization tests can be performed without removing specimens from the chamber. Temperature and humidity were controlled during our experiments via a precision temperature regulator and proportional mixing of dry and moisture-saturated air; while highly uniform UV radiation was attained by attaching the chamber to an integrating sphere-based radiation source. A computer-controlled stepper motor and a transmission system were used to provide precise movement control. The reliability and effectiveness of the apparatus were demonstrated on a model sealant material. The results clearly show that this apparatus provides an excellent platform to study the long-term durability of building joint sealants.
An accelerated exposure and testing apparatus for building joint sealants.
White, C C; Hunston, D L; Tan, K T; Hettenhouser, J; Garver, J D
2013-09-01
The design, fabrication, and implementation of a computer-controlled exposure and testing apparatus for building joint sealants are described in this paper. This apparatus is unique in its ability to independently control and monitor temperature, relative humidity, ultraviolet (UV) radiation, and mechanical deformation. Each of these environmental factors can be controlled precisely over a wide range of conditions during periods of a month or more. Moreover, as controlled mechanical deformations can be generated, in situ mechanical characterization tests can be performed without removing specimens from the chamber. Temperature and humidity were controlled during our experiments via a precision temperature regulator and proportional mixing of dry and moisture-saturated air; while highly uniform UV radiation was attained by attaching the chamber to an integrating sphere-based radiation source. A computer-controlled stepper motor and a transmission system were used to provide precise movement control. The reliability and effectiveness of the apparatus were demonstrated on a model sealant material. The results clearly show that this apparatus provides an excellent platform to study the long-term durability of building joint sealants.
Chopin-Doroteo, Mario; Salgado-Curiel, Rosa M; Pérez-González, José; Marín-Santibáñez, Benjamín M; Krötzsch, Edgar
2018-06-01
Fibrin and hyaluronic acid are important components of the provisional wound matrix. Through interactions with fibroblasts, they provide biophysical cues that regulate the viscoelastic properties of the extracellular matrix. To understand the roles of fibrin and hyaluronic acid in a collagenous environment, we used fibroblast populated collagen lattices (collagen, collagen-fibrin, and collagen-hyaluronic acid). Compared with collagen and collagen-hyaluronic acid cultures, collagen-fibrin cultures showed less contraction, which is correlated with increased elastic (G') and complex (|G*|) moduli, and reduced proportions of dendritic fibroblasts, despite increased αv integrin expression. Stiffness decreased during culture in collagen-fibrin environment, meanwhile phase shift (δ) values increased, clearly associated with the rise in fibrinolytic and gelatinolytic activities. These processes changed the viscoelastic properties of the system toward G' and |G*| values observed on day 5 in collagen cultures. Although less collagen turnover was observed in collagen-fibrin cultures than in collagen and collagen-hyaluronic acid cultures, collagen neosynthesis was apparently insufficient to contribute to the overall viscoelastic properties of the system. Collagen-hyaluronic acid cultures showed very limited changes during time. Firstly, they exhibited the highest δ values, suggesting an increase in the viscous behavior due to the hygroscopic properties of hyaluronic acid. These results showed that fibrin and hyaluronic acid not only affect differently the viscoelastic properties of the culture, they can tune fibroblastic activity by regulating cell attachment and extracellular matrix remodeling. Copyright © 2018 Elsevier Ltd. All rights reserved.
Mills, R W; Ball, I A
1993-01-01
A randomized clinical trial was under-taken to compare the retention of a silver cermet-ionomer cement, Ketac Silver, with a conventional, autopolymerizing BIS-GMA resin sealant, Delton, using matched pairs of fissure sites within each subject's mouth. One hundred twenty matched contralateral pairs of fissure sites in first and second permanent molars of 53 school children were sealed with the two materials. The choice of site and material was selected at random. The ages of the children ranged from five to 16 years; first permanent molars were sealed in the five- to 10-year age group, and second permanent molars in the 11- to 16-year age group. Sealants were assessed as present, partly present, or absent at 6, 12, and 24 months. The number of pairs of sites available for reassessment declined from 102 at six months to 59 at 24 months as patients were lost to the study. Retention rates were higher for the Ketac Silver sealants at all three inspection intervals (P < 0.01): 93% compared with 74% at six months, 81% compared with 65% at 12 months, and 83% compared with 58% at 24 months. When analyzed according to age range, the difference between the retention rates was statistically significant in the five- to 10-year-olds but not significant in the 11- to 16-year-olds. The conclusion reached in this study was that cermet cement was better retained than conventional resin sealants in younger children.
[Evaluation of the effect of one-step self etching adhesives applied in pit and fissure sealing].
Su, Hong-Ru; Xu, Pei-Cheng; Qian, Wen-Hao
2016-06-01
To observe the effect of three one-step self etching adhesive systems used in fit and fissure sealant and explore the feasibility of application in caries prevention in school. Seven hundred and twenty completely erupted mandibular first molars in 360 children aged 7 to 9 years old were chosen. The split-mouth design was used to select one side as the experimental group, divided into A1(Easy One Adper), B1(Adper Easy One), and C1(iBond SE).The contra lateral teeth served as A2,B2 and C2 groups (phosphoric acid). The retention and caries status were regularly reviewed .The clinical effect of the two groups was compared using SPSS19.0 software package for Chi - square test. At 3 and 6 months, pit and fissure sealant retention rate in A1 and A2, B1 and B2,C1 and C2 group had no significant difference. At 12 months, sealant retention in A1 and B1 group was significantly lower than A2 and B2 group (P<0.05). No significant difference was found between C1 and C2 groups (P>0.05). At 24 months, sealant retention rate in A1, B1 and C1 group was significantly lower than A2, B2 and C2 group (P<0.05). The caries rate in A1and A2, B1 and B2, C1 and C2 group had no significant difference during different follow-up time (P>0.05). The clinical anticariogenic effect of three kinds of one-step etching adhesives and phosphoric acid etching sealant was similar .One-step self etching adhesive system was recommended for pit and fissure sealant to improve the students' oral health. The long-term retention rate of one-step self etching adhesive system was lower than the phosphoric acid method to long term observation is needed.
Effect of artificial aging on the bond durability of fissure sealants.
Yun, Xiaofei; Li, Wei; Ling, Chen; Fok, Alex
2013-06-01
To evaluate the effect of artificial aging on the bond durability of fissure sealants in vitro. Twenty bovine incisors received 4 different sealant treatments and were divided into four groups: 1. Ultraseal XT plus (UX); 2. Enamel Loc (EL); 3. 35% phosphoric acid plus Enamel Loc (PEL); 4. Adper Prompt L-Pop plus Clinpro (PPC). Beam-shaped specimens were prepared and randomly divided into three subgroups. One subgroup underwent the microtensile bond strength (µTBS) test after 24-h storage in 37°C water. The other two subgroups were also subjected to the microtensile bond strength test after 5000 and 10,000 thermal cycles, respectively. Another twelve intact human third molars were sealed using 1 of 3 methods and were divided into 3 groups of 4 each: 1. Ultraseal XT plus; 2. Adper Prompt L-Pop plus Clinpro; and 3. Enamel Loc. Two specimens from each group were immersed in a 50% silver nitrate solution for 24 h, followed by exposure to fluorescent light for 8 h, before being scanned in a micro-CT (microcomputer tomography) machine. The other two were handled in the same way after undergoing 10,000 thermal cycles. The CT images obtained were evaluated. All samples from the EL group were broken during preparation, so no µTBS results were available. After 5000 thermal cycles, the bond strengths of the three other groups (UX, PEL, PPC) decreased significantly (p < 0.05). Longer thermocycling (10,000 cycles) resulted in more decreases in µTBS for group PEL and PPC, while the strength of the UX group remained relatively unchanged. After thermocycling, considerable silver penetration could be seen at the sealant/enamel interface of the EL group in micro-CT images. The etch-and-rinse procedure for sealant application promotes higher bond strength under artificial aging. Micro-CT, a nondestructive analytical tool, may be used to evaluate the sealant/enamel interface effectively.
Lequaglie, Cosimo; Giudice, Gabriella; Marasco, Rita; Morte, Aniello Della; Gallo, Massimiliano
2012-10-08
Pulmonary air leaks are common complications of lung resection and result in prolonged hospital stays and increased costs. The purpose of this study was to investigate whether, compared with standard care, the use of a synthetic polyethylene glycol matrix (CoSeal®) could reduce air leaks detected by means of a digital chest drain system (DigiVent™), in patients undergoing lung resection (sutures and/or staples alone). Patients who intraoperatively showed moderate or severe air leaks (evaluated by water submersion tests) were intraoperatively randomized to receive just sutures/staples (control group) or sutures/staples plus CoSeal® (sealant group). Differences among the groups in terms of air leaks, prolonged air leaks, time to chest tube removal, length of hospital stay and related costs were assessed. In total, 216 lung resection patients completed the study. Nineteen patients (18.1%) in the control group and 12 (10.8%) patients in the sealant group experienced postoperative air leaks, while a prolonged air leak was recorded in 11.4% (n=12) of patients in the control group and 2.7% (n=3) of patients in the sealant group. The difference in the incidence of air leaks and prolonged air leaks between the two groups was statistically significant (p=0.0002 and p=0.0013). The mean length of hospital stay was significantly shorter in the sealant group (4 days) than the control group (8 days) (p=0.0001). We also observed lower costs in the sealant group than the control group. The use of CoSeal® may decrease the occurrence and severity of postoperative air leaks after lung resection and is associated with shorter hospital stay. Not registered. The trial was approved by the Institutional Review Board of the IRCCS-CROB Basilicata Regional Cancer Institute, Rionero in Vulture, Italy.
Pretorius, Etheresia; du Plooy, Jenny; Soma, Prashilla; Gasparyan, Armen Yuri
2014-07-01
The study suggests that patients with systemic lupus erythematosus (SLE) present with distinct inflammatory ultrastructural changes such as platelets blebbing, generation of platelet-derived microparticles, spontaneous formation of massive fibrin network and fusion of the erythrocytes membranes. Lupoid platelets actively interact with other inflammatory cells, particularly with white blood cells (WBCs), and the massive fibrin network facilitates such an interaction. It is possible that the concerted actions of platelets, erythrocytes and WBC, caught in the inflammatory fibrin network, predispose to pro-thrombotic states in patients with SLE.
Antibiotic-primed fibrin gel improves outcome in contaminated splenic injury.
Ing, R D; Saxe, J; Hendrick, S; Bailey, J; Diebel, L N; Dulchavsky, S A; Brown, W
1992-07-01
Fibrin gel (FG) has recently been shown to be bactericidal in the management of contaminated hepatic injury; antibiotic loading of fibrin gel (AFG) may augment this effect. We evaluated the antimicrobial properties of FG and AFG in a rat model of contaminated splenic injury. Fibrin gel was made from centrifuged plasma of separate donor rats and bovine thrombin. Antibiotic fibrin gel was similarly produced following intravenous injection of 70 mg/kg ticarcillin. Male Holtzman rats (250-300 g) were anesthetized and a laparotomy done. The abdomen was contaminated with 1 x 10(7) Bacteroides fragilis and the spleen transected in the midportion. Treatment consisted of splenorrhaphy (S) (n = 7), FG application (n = 7), or AFG (n = 7). The animals were autopsied at 1 week to evaluate abscess formation and abdominal adhesions (grade I = none, grade II = mild, grade III = severe). Antibiotic/fibrin gel significantly decreased abscess formation following splenic injury when compared with S (2 of 7 vs. 7 of 7; p less than 0.05 by ANOVA) without an increase in adhesions. Fibrin gel also decreased abscess formation but not significantly (4 of 7 vs. 7 of 7). Histologic analysis confirmed the beneficial effect of FG and AFG on wound healing. The bactericidal effect of FG is improved by antibiotic loading in contaminated intraabdominal injury.
Histopathological effects of fibrin glue on penile fracture in a rat model.
Tasdemir, Cemal; Samdanci, Emine T; Turtay, Muhammet G; Firat, Cemal; Oguzturk, Hakan; Ozdemir, Hulya
2011-12-01
To evaluate both histopathological effects and potential clinical application of fibrin glue on the penile cavernosal tissue. Experimental penile fracture was formed by incising from the proximal dorsal side of the penis in 32 Wistar Albino rats. The rats were randomly assigned to four main groups of eight animals each. In the control group, the incision was not repaired and it was left to secondary healing. In the primary repair group, the incision was primarily repaired. In the fibrin glue group, glue was applied only to the incision. In the final group, fibrin glue was applied to the incision following primary repair. Three weeks later, penectomy tissue was examined histopathologically. When the control group was compared with primary repair+fibrin glue group, the differences in cavernous tissue healing with fibrosis and inflammation were statistically significant (p = 0.04 and 0.01, respectively). The primary repair+fibrin glue group, showed the best cavernous healing with fibrosis observed in only one rat. . There was no significant difference between the control group and the other groups according to cavernous tissue healing with fibrosis and inflammation (p = 0.11 and 0.12). Hyperemia was observed in the all groups of rats. Fibrin glue can be used in cavernoseal surgeries due to its adhesive and potentially anti-inflammatory features.
Fibrin glue as agent for sealing corneal and conjunctival wound leaks.
Scalcione, C; Ortiz-Vaquerizas, D; Said, D G; Dua, H S
2018-02-01
PurposeTo describe a novel use of fibrin glue in managing leaking blebs and leaking wounds following trauma or surgery.MethodsInterventional case series.ResultsWe report eight patients, including three where intra-operative or immediate post-penetrating keratoplasty recalcitrant leaks from the graft-host junction and/or openings created by the needle pass, were noted. All three had thin recipient beds in the sector of leak. This was managed by intra-cameral injection of fibrin glue in the affected quadrant. This stopped the leak and allowed the defect to heal. One patient of Descemets-stripping-endothelial-keratoplasty had leak from the surgical wound, which was also sealed with fibrin glue. Two patients with leaking glaucoma-surgery-related blebs were treated with intra-bleb injection of fibrin glue to stop the leak. One patient with a penetrating corneal injury with a metal wire had a brisk leak upon removal of the wire. This was sealed with fibrin glue. Another patient of chemical burn with spontaneous leaks was managed by glue injection in the perforations. Transient rise of intraocular pressure in one patient with a leaking bleb was the only adverse event recorded.ConclusionThis novel adaptation of the application of fibrin glue can help to deal with persistent intra-operative, post-operative and traumatic aqueous and air leaks.
Ko, Ya-Ping; Flick, Matthew J.
2017-01-01
Fibrinogen not only plays a pivotal role in hemostasis but also serves key roles in antimicrobial host defense. As a rapidly assembled provisional matrix protein, fibrin(ogen) can function as an early line of host protection by limiting bacterial growth, suppressing dissemination of microbes to distant sites, and mediating host bacterial killing. Fibrinogen-mediated host antimicrobial activity occurs predominantly through two general mechanisms, namely, fibrin matrices functioning as a protective barrier and fibrin(ogen) directly or indirectly driving host protective immune function. The potential of fibrin to limit bacterial infection and disease has been countered by numerous bacterial species evolving and maintaining virulence factors that engage hemostatic system components within vertebrate hosts. Bacterial factors have been isolated that simply bind fibrinogen or fibrin, promote fibrin polymer formation, or promote fibrin dissolution. Staphylococcus aureus is an opportunistic gram-positive bacterium, the causative agent of a wide range of human infectious diseases, and a prime example of a pathogen exquisitely sensitive to host fibrinogen. Indeed, current data suggest fibrinogen serves as a context-dependent determinant of host defense or pathogen virulence in Staphylococcus infection whose ultimate contribution is dictated by the expression of S. aureus virulence factors, the path of infection, and the tissue microenvironment. PMID:27056151
Platelet factor 4 (CXCL4) seals blood clots by altering the structure of fibrin.
Amelot, Aymeric A; Tagzirt, Madjid; Ducouret, Guylaine; Kuen, René Lai; Le Bonniec, Bernard F
2007-01-05
Platelet factor-4 (PF4/CXCL4) is an orphan chemokine released in large quantities in the vicinity of growing blood clots. Coagulation of plasma supplemented with a matching amount of PF4 results in a translucent jelly-like clot. Saturating amounts of PF4 reduce the porosity of the fibrin network 4.4-fold and decrease the values of the elastic and loss moduli by 31- and 59-fold, respectively. PF4 alters neither the cleavage of fibrinogen by thrombin nor the cross-linking of protofibrils by activated factor XIII but binds to fibrin and dramatically transforms the structure of the ensuing network. Scanning electron microscopy showed that PF4 gives rise to a previously unreported pattern of polymerization where fibrin assembles to form a sealed network. The subunits constituting PF4 form a tetrahedron having at its corners a RPRH motif that mimics (in reverse orientation) the Gly-His-Arg-Pro-amide peptides that co-crystallize with fibrin. Molecular modeling showed that PF4 could be docked to fibrin with remarkable complementarities and absence of steric clashes, allowing the assembly of irregular polymers. Consistent with this hypothesis, as little as 50 microm the QVRPRHIT peptide derived from PF4 affects the polymerization of fibrin.
An overview on autologous fibrin glue in bone tissue engineering of maxillofacial surgery
Khodakaram-Tafti, Azizollah; Mehrabani, Davood; Shaterzadeh-Yazdi, Hanieh
2017-01-01
The purpose of this review is to have an overview on the applications on the autologous fibrin glue as a bone graft substitute in maxillofacial injuries and defects. A search was conducted using the databases such as Medline or PubMed and Google Scholar for articles from 1985 to 2016. The criteria were “Autograft,” “Fibrin tissue adhesive,” “Tissue engineering,” “Maxillofacial injury,” and “Regenerative medicine.” Bone tissue engineering is a new promising approach for bone defect reconstruction. In this technique, cells are combined with three-dimensional scaffolds to provide a tissue-like structure to replace lost parts of the tissue. Fibrin as a natural scaffold, because of its biocompatibility and biodegradability, and the initial stability of the grafted stem cells is introduced as an excellent scaffold for tissue engineering. It promotes cell migration, proliferation, and matrix making through acceleration in angiogenesis. Growth factors in fibrin glue can stimulate and promote tissue repair. Autologous fibrin scaffolds are excellent candidates for tissue engineering so that they can be produced faster, cheaper, and in larger quantities. In addition, they are easy to use and the probability of viral or prion transmission may be decreased. Therefore, autologous fibrin glue appears to be promising scaffold in regenerative maxillofacial surgery. PMID:28584530
He, S; Ekman, G Jacobsson; Hedner, U
2005-02-01
Fibrin gel structure has been shown to be dependent on the thrombin concentration as well as the rate of thrombin generation. Accordingly, factor VIII (FVIII)- and FIX-deficient plasma (hemophilia A and B) form loose fibrin clots with high permeability constants. By adding rFVIIa in vitro to FVIII-deficient plasma containing platelets (frozen and thawed), the fibrin gel permeability constant normalized, indicating that extra rFVIIa (1.2 microg mL(-1) or higher) induced a tight fibrin structure. Thrombin generation is highly dependent on the number of platelets, and in this study it was demonstrated that the addition of rFVIIa (5 microg mL(-1)) normalizes the fibrin gel permeability in samples containing platelets (frozen-thawed) in numbers of at least down to 20 x 10(6) mL(-1). The effect of rFVIIa was not observed when unfrozen platelets instead of frozen-thawed platelets were added. Neither was any effect on the fibrin permeability seen, in the presence of annexin V, known to block the effect of phospholipids on the platelet surface. This indicates an important role of platelet phospholipids for the effect of rFVIIa. A similar effect on the fibrin permeability of rFVIIa was observed when added to platelet-rich plasma from a patient with Glanzmann thrombasthenia. Recombinant FVIIa has been found to induce hemostasis in patients with hemophilia and inhibitors against FVIII/FIX as well as in patients with Glanzmann thrombasthenia, indicating the importance of the formation of a tight fibrin gel structure, more resistant against premature proteolysis, for maintaining hemostasis. In conclusion, the addition of rFVIIa (5 microg mL(-1)) also substantially decreased the permeability constant of fibrin gels formed in FVIII-deficient plasma in the presence of low numbers of frozen-thawed platelets (down to 20 x 10(6) mL(-1)). A similar pattern was obtained in plasma from a Glanzmann patient. No effect was found in the presence of unfrozen instead of frozen-thawed platelets. Annexin V blocked any effect of rFVIIa. A normalization of the overall fibrinolysis potential (OFP) during the same condition supports the effect of rFVIIa on the fibrin permeability in the presence of a limited number of platelets.
Durability of sealants exposed to outdoor weathering and hot compression cycles
Gregory T. Schueneman; Steven Lacher; Christopher G. Hunt; Christopher C. White; Donald L. Hunston
2011-01-01
Sealants play an important role in weatherproofing structures by filling gaps and preventing air and water intrusion. When incorrectly selected or improperly applied, they may fail quickly, compromising durability of the structure. To ensure reliability and prevent the need for costly repairs to structures, it is necessary to measure durability and predict life...
A Test Method for Monitoring Modulus Changes during Durability Tests on Building Joint Sealants
Christopher C. White; Donald L. Hunston; Kar Tean Tan; Gregory T. Schueneman
2012-01-01
The durability of building joint sealants is generally assessed using a descriptive methodology involving visual inspection of exposed specimens for defects. It is widely known that this methodology has inherent limitations, including that the results are qualitative. A new test method is proposed that provides more fundamental and quantitative information about...
Viscous sealing glass compositions for solid oxide fuel cells
Kim, Cheol Woon; Brow, Richard K.
2016-12-27
A sealant for forming a seal between at least two solid oxide fuel cell components wherein the sealant comprises a glass material comprising B.sub.2O.sub.3 as a principal glass former, BaO, and other components and wherein the glass material is substantially alkali-free and contains less than 30% crystalline material.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-07
... (FAA), DOT. ACTION: Final rule. SUMMARY: We are adopting a new airworthiness directive (AD) for the products listed above. This AD requires a detailed inspection for proper sealant of the left and right... sealant on the left and right pylon firewall structures. We are issuing this AD to detect and correct...
Gel sealants for the mitigation of spontaneous heatings in coal mines. Report of investigations/1995
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miron, Y.
1995-12-31
The U.S. Bureau of Mines evaluated three sealant systems for this purpose, bentonite-water mixtures, silicate gel, and guar gum gels. The guar gum-based gel was the only sealant that possessed the desired properties of elasticity, ease of preparation, adaptability to the mine, and a long life. In addition, since the gel consists mostly of water, it could quench or cool nearby heatings. Optimal formulations were determined in laboratory tests, and then tested in the U.S. Bureau of Mines` Safety Research Coal Mine. Two formulations resulted in stable gels that lasted for at least 12 months in the mine. Semi-continuous preparationmore » of gel using an eductor was evaluated and appears feasible.« less
First impressions about Adherus, a new dural sealant.
Zoia, Cesare; Bongetta, Daniele; Lombardi, Francesco; Custodi, Viola Marta; Pugliese, Raffaelino; Gaetani, Paolo
2015-12-18
The aim of the study is to report our first impressions about Adherus, a novel dural sealant, used in neurosurgical endoscopic transnasal procedures. We retrospectively reviewed the clinical and surgical records of the first 11 patients with intraoperative high-flow cerebrospinal fluid leak treated with the aid of Adherus at our center between February and October 2014. The healing at the level of the dural plasty was monitored and evaluated radiologically and with regular endoscopic inspections. With a median follow-up of 210 days, no postoperative CSF leak or surgical site infections were found in any of the cases. Based on our preliminary experience, this new dural sealant seems to provide an effective aid in dural plasty during endoscopic transphenoidal procedures.
Stretching single fibrin fibers hampers their lysis.
Li, Wei; Lucioni, Tomas; Li, Rongzhong; Bonin, Keith; Cho, Samuel S; Guthold, Martin
2017-09-15
Blood clots, whose main structural component is a mesh of microscopic fibrin fibers, experience mechanical strain from blood flow, clot retraction and interactions with platelets and other cells. We developed a transparent, striated and highly stretchable substrate made from fugitive glue (a styrenic block copolymer) to investigate how mechanical strain affects lysis of single, suspended fibrin fibers. In this suspended fiber assay, lysis manifested itself by fiber elongation, thickening (disassembly), fraying and collapse. Stretching single fibrin fibers significantly hampered their lysis. This effect was seen in uncrosslinked and crosslinked fibers. Crosslinking (without stretching) also hampered single fiber lysis. Our data suggest that strain is a novel mechanosensitive factor that regulates blood clot dissolution (fibrinolysis) at the single fiber level. At the molecular level of single fibrin molecules, strain may distort, or hinder access to, plasmin cleavage sites and thereby hamper lysis. Fibrin fibers are the major structural component of a blood clot. We developed a highly stretchable substrate made from fugitive glue and a suspended fibrin fiber lysis assay to investigate the effect of stretching on single fibrin fibers lysis. The key findings from our experiments are: 1) Fibers thicken and elongate upon lysis; 2) stretching strongly reduces lysis; 3) this effect is more pronounced for uncrosslinked fibers; and 4) stretching fibers has a similar effect on reducing lysis as crosslinking fibers. At the molecular level, strain may distort plasmin cleavage sites, or restrict access to those sites. Our results suggest that strain may be a novel mechanobiological factor that regulates fibrinolysis. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Mullaguri, Harish; Suresh, Nandini; Surendran, Smitha; Velmurugan, Natanasabapathy; Chitra, Selvarajan
2016-05-01
The purpose of this study was to evaluate the influence of pH that is due to setting reaction of Biodentine, glass ionomer cement (GIC), and intermediate restorative material (IRM) on transforming growth factor-β1 (TGF-β1) release and on the fibrin architecture of platelet-rich fibrin (PRF). PRF was obtained from 8 volunteers and layered over the freshly prepared GIC, IRM, and Biodentine mixtures. TGF-β1 release was estimated by using enzyme-linked immunosorbent assay (ELISA), and fibrin structure of PRF was analyzed by using scanning electron microscope at 1 and 5 hours. Biodentine, GIC, and IRM increased the TGF-β1 release in comparison with that of control group (PRF alone) at both 1 and 5 hours. Biodentine released significantly more TGF-β1 than GIC and IRM at 1 hour. At 5 hours both GIC and Biodentine released significantly more TGF-β1 than IRM. The fibrin architecture of the Biodentine group was similar to that of control group at both 1 and 5 hours. In GIC and IRM groups the fibrillar structure of fibrin was collapsed, ill-defined, and cloudy with very thick fibers and irregularly reduced porosities. Biodentine induces larger amount of TGF-β1 release and also maintains the integrity of fibrin structure when compared with GIC and IRM when layered over PRF. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Deposition of Fibrinogen on the Surface of in vitro Thrombi Prevents Platelet Adhesion
Owaynat, Hadil; Yermolenko, Ivan S.; Turaga, Ramya; Lishko, Valeryi K.; Sheller, Michael R.; Ugarova, Tatiana P.
2015-01-01
The initial accumulation of platelets after vessel injury is followed by thrombin-mediated generation of fibrin which is deposited around the plug. While numerous in vitro studies have shown that fibrin is highly adhesive for platelets, the surface of experimental thrombi in vivo contains very few platelets suggesting the existence of natural anti-adhesive mechanisms protecting stabilized thrombi from platelet accumulation and continuous thrombus propagation. We previously showed that adsorption of fibrinogen on pure fibrin clots results in the formation of a nonadhesive matrix, highlighting a possible role of this process in surface-mediated control of thrombus growth. However, the deposition of fibrinogen on the surface of blood clots has not been examined. In this study, we investigated the presence of intact fibrinogen on the surface of fibrin-rich thrombi generated from flowing blood and determined whether deposited fibrinogen is nonadhesive for platelets. Stabilized fibrin-rich thrombi were generated using a flow chamber and the time that platelets spend on the surface of thrombi was determined by video recording. The presence of fibrinogen and fibrin on the surface of thrombi was analyzed by confocal microscopy using specific antibodies. Examination of the spatial distribution of two proteins revealed the presence of intact fibrinogen on the surface of stabilized thrombi. By manipulating the surface of thrombi to display either fibrin or intact fibrinogen, we found that platelets adhere to fibrin- but not to fibrinogen-coated thrombi. These results indicate that the fibrinogen matrix assembled on the outer layer of stabilized in vitro thrombi protects them from platelet adhesion. PMID:26482763
Chignon-Sicard, Bérengère; Georgiou, Charalambos A; Fontas, Eric; David, Sylvain; Dumas, Pierre; Ihrai, Tarik; Lebreton, Elisabeth
2012-12-01
Application of platelet concentrates to wounds could speed healing. Leukocyte- and platelet-rich fibrin, a relatively recent development, stands out from the other preparations. This prospective, randomized, controlled clinical trial studied the rate of healing of postoperative hand wounds after a single application of leukocyte- and platelet-rich fibrin. Eligible patients were healthy individuals older than 18 years who had been scheduled for elective McCash (open palm) surgery for Dupuytren disease at the Plastic and Hand Surgery Department of Nice's University Hospital between August of 2007 and February of 2010. The control group received the reference care of petroleum jelly mesh (Vaselitulle), and test patients had leukocyte- and platelet-rich fibrin applied. The primary endpoint was healing delay measured in postoperative days. Secondary endpoints included pain, bleeding, and wound exudate. The trial was carried out as a single-blind trial. Among the 68 randomized patients, 33 patients in the leukocyte- and platelet-rich fibrin group and 31 in the Vaselitulle group were analyzed. Primary endpoint analysis showed a median healing delay of 24 days (interquartile range, 18 to 28 days) for the fibrin group and 29 days (interquartile range, 26 to 35 days) for the Vaselitulle group (p = 0.014, log-rank test). Postoperative pain assessment, bleeding, and exudate were always lower for the fibrin group, but not significantly so. The authors trial demonstrates that a single leukocyte- and platelet-rich fibrin application on fresh postoperative hand wounds shows a median improvement of 5 days in comparison with the standard treatment. Therapeutic, II.
Deposition of fibrinogen on the surface of in vitro thrombi prevents platelet adhesion.
Owaynat, Hadil; Yermolenko, Ivan S; Turaga, Ramya; Lishko, Valeryi K; Sheller, Michael R; Ugarova, Tatiana P
2015-12-01
The initial accumulation of platelets after vessel injury is followed by thrombin-mediated generation of fibrin which is deposited around the plug. While numerous in vitro studies have shown that fibrin is highly adhesive for platelets, the surface of experimental thrombi in vivo contains very few platelets suggesting the existence of natural anti-adhesive mechanisms protecting stabilized thrombi from platelet accumulation and continuous thrombus propagation. We previously showed that adsorption of fibrinogen on pure fibrin clots results in the formation of a nonadhesive matrix, highlighting a possible role of this process in surface-mediated control of thrombus growth. However, the deposition of fibrinogen on the surface of blood clots has not been examined. In this study, we investigated the presence of intact fibrinogen on the surface of fibrin-rich thrombi generated from flowing blood and determined whether deposited fibrinogen is nonadhesive for platelets. Stabilized fibrin-rich thrombi were generated using a flow chamber and the time that platelets spend on the surface of thrombi was determined by video recording. The presence of fibrinogen and fibrin on the surface of thrombi was analyzed by confocal microscopy using specific antibodies. Examination of the spatial distribution of two proteins revealed the presence of intact fibrinogen on the surface of stabilized thrombi. By manipulating the surface of thrombi to display either fibrin or intact fibrinogen, we found that platelets adhere to fibrin- but not to fibrinogen-coated thrombi. These results indicate that the fibrinogen matrix assembled on the outer layer of stabilized in vitro thrombi protects them from platelet adhesion. Copyright © 2015 Elsevier Ltd. All rights reserved.
Fabrication and physical and biological properties of fibrin gel derived from human plasma.
Zhao, Haiguang; Ma, Lie; Zhou, Jie; Mao, Zhengwei; Gao, Changyou; Shen, Jiacong
2008-03-01
The fast development of tissue engineering and regenerative medicine drives the old biomaterials, for example, fibrin glue, to find new applications in these areas. Aiming at developing a commercially available hydrogel for cell entrapment and delivery, in this study we optimized the fabrication and gelation conditions of fibrin gel. Fibrinogen was isolated from human plasma by a freeze-thaw circle. Gelation of the fibrinogen was accomplished by mixing with thrombin. Absorbance of the fibrinogen/thrombin mixture at 550 nm as a function of reaction time was monitored by UV-VIS spectroscopy. It was found that the clotting time is significantly influenced by the thrombin concentration and the temperature, while less influenced by the fibrinogen concentration. After freeze-drying, the fibrin gel was characterized by scanning electron microscopy (SEM), revealing fibrous microstructure. Thermal gravimetric analysis found that the degradation temperature of the crosslinked fibrin gel starts from 288 degrees C, which is about 30 degrees C higher than that of the fibrinogen. The hydrogel has an initial water-uptake ratio of approximately 50, decreased to 30-40 after incubation in water for 11 h depending on the thrombin concentration. The fibrin gels lost their weights in PBS very rapidly, while slowly in DMEM/fetal bovine serum and DMEM. In vitro cell culture found that human fibroblasts could normally proliferate in the fibrin gel with spreading morphology. In conclusion, the fibrin gel containing higher concentration of fibrinogen (20 mg ml(-1)) and thrombin (5 U ml(-1)) has suitable gelation time and handling properties, and thus is applicable as a delivery vehicle for cells such as fibroblasts.
Fabrication and physical and biological properties of fibrin gel derived from human plasma
NASA Astrophysics Data System (ADS)
Zhao, Haiguang; Ma, Lie; Zhou, Jie; Mao, Zhengwei; Gao, Changyou; Shen, Jiacong
2008-03-01
The fast development of tissue engineering and regenerative medicine drives the old biomaterials, for example, fibrin glue, to find new applications in these areas. Aiming at developing a commercially available hydrogel for cell entrapment and delivery, in this study we optimized the fabrication and gelation conditions of fibrin gel. Fibrinogen was isolated from human plasma by a freeze-thaw circle. Gelation of the fibrinogen was accomplished by mixing with thrombin. Absorbance of the fibrinogen/thrombin mixture at 550 nm as a function of reaction time was monitored by UV-VIS spectroscopy. It was found that the clotting time is significantly influenced by the thrombin concentration and the temperature, while less influenced by the fibrinogen concentration. After freeze-drying, the fibrin gel was characterized by scanning electron microscopy (SEM), revealing fibrous microstructure. Thermal gravimetric analysis found that the degradation temperature of the crosslinked fibrin gel starts from 288 °C, which is about 30 °C higher than that of the fibrinogen. The hydrogel has an initial water-uptake ratio of ~50, decreased to 30-40 after incubation in water for 11 h depending on the thrombin concentration. The fibrin gels lost their weights in PBS very rapidly, while slowly in DMEM/fetal bovine serum and DMEM. In vitro cell culture found that human fibroblasts could normally proliferate in the fibrin gel with spreading morphology. In conclusion, the fibrin gel containing higher concentration of fibrinogen (20 mg ml-1) and thrombin (5 U ml-1) has suitable gelation time and handling properties, and thus is applicable as a delivery vehicle for cells such as fibroblasts.
Lytic and mechanical stability of clots composed of fibrin and blood vessel wall components.
Rottenberger, Z; Komorowicz, E; Szabó, L; Bóta, A; Varga, Z; Machovich, R; Longstaff, C; Kolev, K
2013-03-01
Proteases expressed in atherosclerotic plaque lesions generate collagen fragments, release glycosaminoglycans (chondroitin sulfate [CS] and dermatan sulfate [DS]) and expose extracellular matrix (ECM) proteins (e.g. decorin) at sites of fibrin formation. Here we address the effect of these vessel wall components on the lysis of fibrin by the tissue plasminogen activator (tPA)/plasminogen system and on the mechanical stability of clots. MMP-8-digested collagen fragments, isolated CS, DS, glycosylated decorin and its core protein were used to prepare mixed matrices with fibrin (additives present at a 50-fold lower mass concentration than fibrinogen). Scanning electron microscopy (SEM) showed that the presence of ECM components resulted in a coarse fibrin structure, most pronounced for glycosylated decorin causing an increase in the median fiber diameter from 85 to 187 nm. Rheological measurements indicated that these structural alterations were coupled to decreased shear resistance (1.8-fold lower shear stress needed for gel/fluid transition of the clots containing glycosylated decorin) and rigidity (reduction of the storage modulus from 54.3 to 33.2 Pa). The lytic susceptibility of the modified fibrin structures was increased. The time to 50% lysis by plasmin was reduced approximately 2-fold for all investigated ECM components (apart from the core protein of decorin which produced a moderate reduction of the lysis time by 25%), whereas fibrin-dependent plasminogen activation by tPA was inhibited by up to 30%. ECM components compromise the chemical and mechanical stability of fibrin as a result of changes in its ultrastructure. © 2012 International Society on Thrombosis and Haemostasis.
Llucià‐Valldeperas, Aida; Soler‐Botija, Carolina; Gálvez‐Montón, Carolina; Roura, Santiago; Prat‐Vidal, Cristina; Perea‐Gil, Isaac; Sanchez, Benjamin; Bragos, Ramon; Vunjak‐Novakovic, Gordana
2016-01-01
Abstract Cardiac cells are subjected to mechanical and electrical forces, which regulate gene expression and cellular function. Therefore, in vitro electromechanical stimuli could benefit further integration of therapeutic cells into the myocardium. Our goals were (a) to study the viability of a tissue‐engineered construct with cardiac adipose tissue‐derived progenitor cells (cardiac ATDPCs) and (b) to examine the effect of electromechanically stimulated cardiac ATDPCs within a myocardial infarction (MI) model in mice for the first time. Cardiac ATDPCs were electromechanically stimulated at 2‐millisecond pulses of 50 mV/cm at 1 Hz and 10% stretching during 7 days. The cells were harvested, labeled, embedded in a fibrin hydrogel, and implanted over the infarcted area of the murine heart. A total of 39 animals were randomly distributed and sacrificed at 21 days: groups of grafts without cells and with stimulated or nonstimulated cells. Echocardiography and gene and protein analyses were also carried out. Physiologically stimulated ATDPCs showed increased expression of cardiac transcription factors, structural genes, and calcium handling genes. At 21 days after implantation, cardiac function (measured as left ventricle ejection fraction between presacrifice and post‐MI) increased up to 12% in stimulated grafts relative to nontreated animals. Vascularization and integration with the host blood supply of grafts with stimulated cells resulted in increased vessel density in the infarct border region. Trained cells within the implanted fibrin patch expressed main cardiac markers and migrated into the underlying ischemic myocardium. To conclude, synchronous electromechanical cell conditioning before delivery may be a preferred alternative when considering strategies for heart repair after myocardial infarction. Stem Cells Translational Medicine 2017;6:970–981 PMID:28297585
Llucià-Valldeperas, Aida; Soler-Botija, Carolina; Gálvez-Montón, Carolina; Roura, Santiago; Prat-Vidal, Cristina; Perea-Gil, Isaac; Sanchez, Benjamin; Bragos, Ramon; Vunjak-Novakovic, Gordana; Bayes-Genis, Antoni
2017-03-01
Cardiac cells are subjected to mechanical and electrical forces, which regulate gene expression and cellular function. Therefore, in vitro electromechanical stimuli could benefit further integration of therapeutic cells into the myocardium. Our goals were (a) to study the viability of a tissue-engineered construct with cardiac adipose tissue-derived progenitor cells (cardiac ATDPCs) and (b) to examine the effect of electromechanically stimulated cardiac ATDPCs within a myocardial infarction (MI) model in mice for the first time. Cardiac ATDPCs were electromechanically stimulated at 2-millisecond pulses of 50 mV/cm at 1 Hz and 10% stretching during 7 days. The cells were harvested, labeled, embedded in a fibrin hydrogel, and implanted over the infarcted area of the murine heart. A total of 39 animals were randomly distributed and sacrificed at 21 days: groups of grafts without cells and with stimulated or nonstimulated cells. Echocardiography and gene and protein analyses were also carried out. Physiologically stimulated ATDPCs showed increased expression of cardiac transcription factors, structural genes, and calcium handling genes. At 21 days after implantation, cardiac function (measured as left ventricle ejection fraction between presacrifice and post-MI) increased up to 12% in stimulated grafts relative to nontreated animals. Vascularization and integration with the host blood supply of grafts with stimulated cells resulted in increased vessel density in the infarct border region. Trained cells within the implanted fibrin patch expressed main cardiac markers and migrated into the underlying ischemic myocardium. To conclude, synchronous electromechanical cell conditioning before delivery may be a preferred alternative when considering strategies for heart repair after myocardial infarction. Stem Cells Translational Medicine 2017;6:970-981. © 2016 The Authors Stem Cells Translational Medicine published by Wiley Periodicals, Inc. on behalf of AlphaMed Press.
Bhat, Payal; Singh, Nittin Dev; Leishangthem, Geeta Devi; Kaur, Amninder; Mahajan, Vishal; Banga, Harmanjit Singh; Brar, Rajinder Singh
2016-09-01
Infectious porcine bronchopneumonia, caused by Pasteurella multocida , is a widespread disease of major economic significance. Thus, the aim of the present study was to diagnose swine Pasteurellosis using gross, histopathological, and immunopathological approaches in the swine population of Punjab and to compare the efficacy of immunohistochemical (IHC) techniques with conventional diagnostic techniques. A total of 71 adult swine lung samples showing gross pneumonic changes were collected along with the associated lymph nodes to carry out the study. The collected samples were then processed for histopathological and IHC studies. Out of the total 71 lung samples, 26 samples were found to be suspected for Pasteurellosis as per the microscopic changes observed, and out of these 26 samples, 16 cases were confirmed to be positive for Pasteurellosis by IHC. Varied macroscopic changes noted in lungs were pneumonic patches with consolidation of many lobes, congestion, and focal hemorrhages. Main lesions associated with lymph nodes were its enlargement and hemorrhages. Histologically, the lung showed fibrinous and suppurative bronchopneumonia, multifocal suppuration, thickening of septa with fibrin combined with cellular infiltration and edema. The higher IHC expression of P. multocida was seen in the bronchial epithelium besides in alveolar and bronchial exudate. Moreover, on comparing the histopathological and IHC scores which were calculated on the basis of characteristic microscopic lesions and number of antigen positive cells, respectively, a significant positive correlation (r=0.4234) was found. It was concluded that swine population of Punjab is having P. multocida infection. The gross and histopathological lesions can be helpful in the preliminary diagnosis of Pasteurellosis but needs to be supplemented by other immunodiagnostic tests. Moreover, IHC technique proved to be a specific, reliable, precise, and rapid technique to supplement these conventional methods of diagnosis for Pasteurellosis.
Zong, Jian-Chun; Mosca, Michael J; Degen, Ryan M; Lebaschi, Amir; Carballo, Camila; Carbone, Andrew; Cong, Guang-Ting; Ying, Liang; Deng, Xiang-Hua; Rodeo, Scott A
2017-04-01
Bone marrow aspirate has been used in recent years to augment tendon-to-bone healing, including in rotator cuff repair. However, the healing mechanism in cell-based therapy has not been elucidated in detail. Sixteen athymic nude rats were randomly allocated to 2 groups: experimental (human mesenchymal stem cells in fibrin glue carrier) and control (fibrin glue only). Animals were sacrificed at 2 and 4 weeks. Immunohistochemical staining was performed to evaluate Indian hedgehog (Ihh) signaling and SOX9 signaling in the healing enthesis. Macrophages were identified using CD68 and CD163 staining, and proliferating cells were identified using proliferating cell nuclear antigen staining. More organized and stronger staining for collagen II and a higher abundance of SOX9 + cells were observed at the enthesis in the experimental group at 2 weeks. There was significantly higher Gli1 and Patched1 expression in the experimental group at the enthesis at 2 weeks and higher numbers of Ihh + cells in the enthesis of the experimental group vs control at both 2 weeks and 4 weeks postoperatively. There were more CD68 + cells localized to the tendon midsubstance at 2 weeks compared with 4 weeks, and there was a higher level of CD163 staining in the tendon midsubstance in the experimental group than in the control group at 4 weeks. Stem cell application had a positive effect on fibrocartilage formation at the healing rotator cuff repair site. Both SOX9 and Ihh signaling appear to play an important role in the healing process. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
di Lauro, A E; Abbate, D; Dell'Angelo, B; Iannaccone, G A; Scotto, F; Sammartino, G
2015-11-02
Leukocyte-platelet rich fibrin belongs to a second generation of platelet concentrates that does not need biochemical blood manipulation. It is used for tissue healing and regeneration in periodontal and oral-maxillofacial surgery. We report two cases of hyperplastic gingival lesions treated by exeresis and application of leukocyte-platelet rich fibrin membranes in order to improve and accelerate tissue healing. Two patients (a 78-year-old Caucasian woman and a 30-year-old Caucasian man) were treated for hyperplastic gingival lesions. They underwent to exeresis of lesions and application of leukocyte-platelet rich fibrin membranes. Tissue healing was clinically evaluated after 1, 3, 7, 14 and 30 postoperative days. No recurrences were observed after 2 years of semi-annual follow up. We obtained rapid and good healing of soft tissues probably due to the elevated content of leukocytes, platelets and growth factors in the leukocyte-platelet rich fibrin. Based on our results we suggest the use of leukocyte-platelet rich fibrin to cover wounds after exeresis of oral neoformations such as hyperplastic gingival lesions.
Fibrin glue as a protective tool for microanastomoses in limb reconstructive surgery
Langer, Stefan; Schildhauer, Thomas A.; Dudda, Marcel; Sauber, Jeannine; Spindler, Nick
2015-01-01
Aim: Fibrin glue becomes a more and more routinely used tool for stabilization of microanastomoses and nerve repair. This paper summarizes the technical properties and advantages of its use in a wide variety of microsurgical contexts, and includes an exemplary limb reconstructive case. Patients and methods: A total of 131 patients who had undergone elective and emergency microsurgery mainly of the limbs were retrospectively analyzed, as was the use of free flaps. Results: The use of fibrin glue allows for proper positioning of anastomoses and repaired nerves. No torsion of the pedicle could be seen. The flap survival rated >94%. The fibrin glue could stay in place in >99%. In the rare case of revision, the fibrin glue could easily be removed without damaging the region of the microanastomosis. Conclusion: Fibrin glue should not be used to repair insufficient, i.e., leaking anastomoses, but it does protect the site of anastomosis from tissue and fluid pressure. It prevents the pedickle from torsion and its use facilitates relocation of the microanastomoses in cases of revision surgery. PMID:26759762
Axillary lymphadenectomy for breast cancer in elderly patients and fibrin glue
2013-01-01
Background Axillary lymphadenectomy or sentinel biopsy is integral part of breast cancer treatment, yet seroma formation occurs in 15-85% of cases. Among methods employed to reduce seroma magnitude and duration, fibrin glue has been proposed in numerous studies with controversial results. Methods Thirty patients over 60 years underwent quadrantectomy or mastectomy with level I/II axillary lymphadenectomy; a suction drain was fitted in all patients. Fibrin glue spray were applied to the axillary fossa in 15 patients; the other 15 patients were treated with harmonic scalpel. Results Suction drainage was removed between post-operative Days 3 and 4. Seroma magnitude and duration were not significant in patients receiving fibrin glue compared with the harmonic scalpel group. Conclusions Use of fibrin glue does not always prevent seroma formation, but can reduce seroma magnitude, duration and necessary evacuative punctures. PMID:24266959
Watertight cataract incision closure using fibrin tissue adhesive.
Hovanesian, John A; Karageozian, Vicken H
2007-08-01
To determine whether a simple method for applying fibrin tissue adhesive to a clear corneal cataract incision can create a watertight seal. Laboratory investigation. Clear corneal cataract incisions were simulated in 8 eye-bank eyes. In 4 eyes, fibrin adhesive was applied to the incision in a simple manner; the other 4 eyes were controls with no adhesive. Each eye was tested under low pressure conditions to detect fluid ingress of India Ink on the eye's surface. The eyes were tested again with external compression to distort the incision to detect fluid egress. In the eyes with fibrin adhesive, there was no egress of fluid with incision distortion and no ingress of India Ink. In the 4 eyes without adhesive, there was ingress and egress of fluid. A simple method of applying fibrin adhesive to cataract incisions created a watertight seal.
CYLD Enhances Severe Listeriosis by Impairing IL-6/STAT3-Dependent Fibrin Production
Nishanth, Gopala; Deckert, Martina; Wex, Katharina; Massoumi, Ramin; Schweitzer, Katrin; Naumann, Michael; Schlüter, Dirk
2013-01-01
The facultative intracellular bacterium Listeria monocytogenes (Lm) may cause severe infection in humans and livestock. Control of acute listeriosis is primarily dependent on innate immune responses, which are strongly regulated by NF-κB, and tissue protective factors including fibrin. However, molecular pathways connecting NF-κB and fibrin production are poorly described. Here, we investigated whether the deubiquitinating enzyme CYLD, which is an inhibitor of NF-κB-dependent immune responses, regulated these protective host responses in murine listeriosis. Upon high dose systemic infection, all C57BL/6 Cyld−/− mice survived, whereas 100% of wildtype mice succumbed due to severe liver pathology with impaired pathogen control and hemorrhage within 6 days. Upon in vitro infection with Lm, CYLD reduced NF-κB-dependent production of reactive oxygen species, interleukin (IL)-6 secretion, and control of bacteria in macrophages. Furthermore, Western blot analyses showed that CYLD impaired STAT3-dependent fibrin production in cultivated hepatocytes. Immunoprecipitation experiments revealed that CYLD interacted with STAT3 in the cytoplasm and strongly reduced K63-ubiquitination of STAT3 in IL-6 stimulated hepatocytes. In addition, CYLD diminished IL-6-induced STAT3 activity by reducing nuclear accumulation of phosphorylated STAT3. In vivo, CYLD also reduced hepatic STAT3 K63-ubiquitination and activation, NF-κB activation, IL-6 and NOX2 mRNA production as well as fibrin production in murine listeriosis. In vivo neutralization of IL-6 by anti-IL-6 antibody, STAT3 by siRNA, and fibrin by warfarin treatment, respectively, demonstrated that IL-6-induced, STAT3-mediated fibrin production significantly contributed to protection in Cyld−/− mice. In addition, in vivo Cyld siRNA treatment increased STAT3 phosphorylation, fibrin production, pathogen control and survival of Lm-infected WT mice illustrating that therapeutic inhibition of CYLD augments the protective NF-κB/IL-6/STAT3 pathway and fibrin production. PMID:23825949
CYLD enhances severe listeriosis by impairing IL-6/STAT3-dependent fibrin production.
Nishanth, Gopala; Deckert, Martina; Wex, Katharina; Massoumi, Ramin; Schweitzer, Katrin; Naumann, Michael; Schlüter, Dirk
2013-01-01
The facultative intracellular bacterium Listeria monocytogenes (Lm) may cause severe infection in humans and livestock. Control of acute listeriosis is primarily dependent on innate immune responses, which are strongly regulated by NF-κB, and tissue protective factors including fibrin. However, molecular pathways connecting NF-κB and fibrin production are poorly described. Here, we investigated whether the deubiquitinating enzyme CYLD, which is an inhibitor of NF-κB-dependent immune responses, regulated these protective host responses in murine listeriosis. Upon high dose systemic infection, all C57BL/6 Cyld(-/-) mice survived, whereas 100% of wildtype mice succumbed due to severe liver pathology with impaired pathogen control and hemorrhage within 6 days. Upon in vitro infection with Lm, CYLD reduced NF-κB-dependent production of reactive oxygen species, interleukin (IL)-6 secretion, and control of bacteria in macrophages. Furthermore, Western blot analyses showed that CYLD impaired STAT3-dependent fibrin production in cultivated hepatocytes. Immunoprecipitation experiments revealed that CYLD interacted with STAT3 in the cytoplasm and strongly reduced K63-ubiquitination of STAT3 in IL-6 stimulated hepatocytes. In addition, CYLD diminished IL-6-induced STAT3 activity by reducing nuclear accumulation of phosphorylated STAT3. In vivo, CYLD also reduced hepatic STAT3 K63-ubiquitination and activation, NF-κB activation, IL-6 and NOX2 mRNA production as well as fibrin production in murine listeriosis. In vivo neutralization of IL-6 by anti-IL-6 antibody, STAT3 by siRNA, and fibrin by warfarin treatment, respectively, demonstrated that IL-6-induced, STAT3-mediated fibrin production significantly contributed to protection in Cyld(-/-) mice. In addition, in vivo Cyld siRNA treatment increased STAT3 phosphorylation, fibrin production, pathogen control and survival of Lm-infected WT mice illustrating that therapeutic inhibition of CYLD augments the protective NF-κB/IL-6/STAT3 pathway and fibrin production.
Podolnikova, Nataly P.; Yakovlev, Sergiy; Yakubenko, Valentin P.; Wang, Xu; Gorkun, Oleg V.; Ugarova, Tatiana P.
2014-01-01
The currently available antithrombotic agents target the interaction of platelet integrin αIIbβ3 (GPIIb-IIIa) with fibrinogen during platelet aggregation. Platelets also bind fibrin formed early during thrombus growth. It was proposed that inhibition of platelet-fibrin interactions may be a necessary and important property of αIIbβ3 antagonists; however, the mechanisms by which αIIbβ3 binds fibrin are uncertain. We have previously identified the γ370–381 sequence (P3) in the γC domain of fibrinogen as the fibrin-specific binding site for αIIbβ3 involved in platelet adhesion and platelet-mediated fibrin clot retraction. In the present study, we have demonstrated that P3 can bind to several discontinuous segments within the αIIb β-propeller domain of αIIbβ3 enriched with negatively charged and aromatic residues. By screening peptide libraries spanning the sequence of the αIIb β-propeller, several sequences were identified as candidate contact sites for P3. Synthetic peptides duplicating these segments inhibited platelet adhesion and clot retraction but not platelet aggregation, supporting the role of these regions in fibrin recognition. Mutant αIIbβ3 receptors in which residues identified as critical for P3 binding were substituted for homologous residues in the I-less integrin αMβ2 exhibited reduced cell adhesion and clot retraction. These residues are different from those that are involved in the coordination of the fibrinogen γ404–411 sequence and from auxiliary sites implicated in binding of soluble fibrinogen. These results map the binding of fibrin to multiple sites in the αIIb β-propeller and further indicate that recognition specificity of αIIbβ3 for fibrin differs from that for soluble fibrinogen. PMID:24338009
Jenkins, Julia; Modarai, Bijan; Wiethoff, Andrea J.; Phinikaridou, Alkystis; Grover, Steven P.; Patel, Ashish S.; Schaeffter, Tobias; Smith, Alberto; Botnar, Rene M.
2014-01-01
Objective Deep venous thrombosis is a major health problem. Thrombolytic therapies are effective in recanalizing the veins and preventing post-thrombotic complications, but there is no consensus on selection criteria. The aim of this study was to investigate a fibrin-specific MRI contrast agent (EP-2104R) for the accurate quantification of thrombus’ fibrin content in vivo and for the identification of thrombus suitable for thrombolysis. Approach and Results Venous thrombosis was induced in the inferior vena cava of 8- to 10-week-old male BALB/C mice and MRI performed 2, 4, 7, 10, 14, and 21 days later. Eighteen mice were scanned at each time point pre and 2 hours post injection of EP-2104R (8.0 μmol/kg) with 12 mice at each time point used to correlate fibrin contrast uptake with thrombus’ histological stage and fibrin content. Six mice at each time point were immediately subjected to intravascular thrombolytic therapy (10 mg/kg of tissue-type plasminogen activator). Mice were imaged to assess response to lytic therapy 24 hours after thrombolytic treatment. Two mice at each time point were scanned post injection of 0.2 mmol/kg of Gd-DTPA (gadolinium with diethylenetriaminepentacetate, Magnevist, Schering AG, Berlin, Germany) for control purpose. Contrast uptake was correlated positively with the fibrin content of the thrombus measured by Western blotting (R2=0.889; P<0.001). Thrombus relaxation rate (R1) post contrast and the change in visualized thrombus size on late gadolinium enhancement inversion recovery MRI pre–EP-2104R and post–EP-2104R injection were the best predictors for successful thrombolysis (area under the curve, 0.989 [95% confidence interval, 0.97–1.00] and 0.994 [95% confidence interval, 0.98–1.00] respectively). Conclusions MRI with a fibrin-specific contrast agent accurately estimates thrombus fibrin content in vivo and identifies thrombi that are amenable for thrombolysis. PMID:24723557
Evaluation of thrombelastographic platelet-mapping in healthy cats.
Blois, Shauna L; Banerjee, Amrita; Wood, R Darren
2012-06-01
Thrombelastography (TEG) permits analysis of clot formation but it is not specific for platelet activity. TEG PlateletMapping (TEG-PM) is a modification of TEG that uses adenosine diphosphate (ADP) and arachidonic acid (AA) as platelet agonists to define the contribution of platelets to clot formation. The objectives of this study were to determine values for TEG-PM in healthy cats and the interassay variation of TEG-PM. TEG-PM analysis was performed on blood specimens collected from 12 healthy cats and was repeated using a second blood specimen collected 2 hours later. Maximum amplitudes generated by thrombin (MA(thrombin)), fibrin (MA(fibrin)), ADP-stimulated platelet activity (MA(ADP)), and AA-stimulated platelet activity (MA(AA)) were recorded. Mean ± SD for MA(thrombin) was 51.1 ± 8.5 mm, for MA(fibrin) was 32.3 ± 17.7 mm, for MA(ADP) was 32.3 ± 15.0 mm, and for MA(AA) was 24.5 ± 12.2 mm. Mean MA(ADP) and MA(fibrin) were not significantly different, whereas mean MA(AA) was significantly lower than mean MA(fibrin). Results from the first and second specimens were not significantly different. Correlation between the first and second specimens was moderate for MA(thrombin), MA(fibrin), and MA(ADP), but was poor for MA(AA). A high degree of variability (coefficient of variation 47.7-60.0%) was observed for MA(fibrin), MA(ADP), and MA(AA). As MA(ADP) and MA(AA) (AA) were the same as or lower than MA(fibrin), a valid baseline to determine platelet-stimulated clot formation could not be established. Considerable interassay variation and wide intervals for MA(fibrin), MA(ADP), and MA(AA) values in this study indicate that TEG-PM should be used cautiously in feline patients. Several preanalytical factors should be examined in further detail. © 2012 American Society for Veterinary Clinical Pathology.
Griffin, Susan O; Naavaal, Shillpa; Scherrer, Christina; Patel, Mona; Chattopadhyay, Sajal
2017-03-01
A recently updated Community Guide systematic review of the effectiveness of school sealant programs (SSPs) still found strong evidence that SSPs reduced dental caries among schoolchildren. This follow-up systematic review updates SSP cost and benefit information from the original 2002 review. Using Community Guide economic review methods, the authors searched the literature from January 2000 to November 20, 2014. The final body of evidence included 14 studies-ten from the current search and four with cost information from the 2002 review. Nine studies had information on SSP costs; six on sealant benefit (averted treatment costs and productivity losses); four on SSP net cost (cost minus benefit); and three on net cost to Medicaid of clinically delivered sealants. The authors imputed productivity losses and discounted costs/outcomes when this information was missing. The analysis, conducted in 2015, reported all values in 2014 U.S. dollars. The median one-time SSP cost per tooth sealed was $11.64. Labor accounted for two thirds of costs, and time to provide sealants was a major cost driver. The median annual economic benefit was $6.29, suggesting that over 4 years the SSP benefit ($23.37 at a 3% discount rate) would exceed costs by $11.73 per sealed tooth. In addition, two of four economic models and all three analyses of Medicaid claims data found that SSP benefit to society exceeded SSP cost. Recent evidence indicates the benefits of SSPs exceed their costs when SSPs target schools attended by a large number of high-risk children. Published by Elsevier Inc.
Van Metre, Peter C.; Mahler, Barbara J.
2013-01-01
Recent studies have concluded that coal-tar-based pavement sealants are a major source of polycyclic aromatic hydrocarbons (PAHs) in urban settings in large parts of the United States. In 2006, Austin, TX, became the first jurisdiction in the U.S. to ban the use of coal-tar sealants. We evaluated the effect of Austin’s ban by analyzing PAHs in sediment cores and bottom-sediment samples collected in 1998, 2000, 2001, 2012, and 2014 from Lady Bird Lake, the principal receiving water body for Austin urban runoff. The sum concentration of the 16 EPA Priority Pollutant PAHs (∑PAH16) in dated core intervals and surficial bottom-sediment samples collected from sites in the lower lake declined about 44% from 1998–2005 to 2006–2014 (means of 7980 and 4500 μg kg–1, respectively), and by 2012–2014, the decline was about 58% (mean of 3320 μg kg–1). Concentrations of ∑PAH16 in bottom sediment from two of three mid-lake sites decreased by about 71 and 35% from 2001 to 2014. Concentrations at a third site increased by about 14% from 2001 to 2014. The decreases since 2006 reverse a 40-year (1959–1998) upward trend. Despite declines in PAH concentrations, PAH profiles and source-receptor modeling results indicate that coal-tar sealants remain the largest PAH source to the lake, implying that PAH concentrations likely will continue to decline as stocks of previously applied sealant gradually become depleted.
A bird's-eye view of cell therapy and tissue engineering for cardiac regeneration.
Soler-Botija, Carolina; Bagó, Juli R; Bayes-Genis, Antoni
2012-04-01
Complete recovery of ischemic cardiac muscle after myocardial infarction is still an unresolved concern. In recent years, intensive research efforts have focused on mimicking the physical and biological properties of myocardium for cardiac repair. Here we show how heart regeneration approaches have evolved from cell therapy to refined tissue engineering. Despite progressive improvements, the best cell type and delivery strategy are not well established. Our group has identified a new population of cardiac adipose tissue-derived progenitor cells with inherent cardiac and angiogenic potential that is a promising candidate for cell therapy to restore ischemic myocardium. We also describe results from three strategies for cell delivery into a murine model of myocardial infarction: intramyocardial injection, implantation of a fibrin patch loaded with cells, and an engineered bioimplant (a combination of chemically designed scaffold, peptide hydrogel, and cells); dual-labeling noninvasive bioluminescence imaging enables in vivo monitoring of cardiac-specific markers and cell survival. © 2012 New York Academy of Sciences.
Mischke, R; Wohlsein, P; Schoon, H-A
2005-01-01
The objective of the study was to examine the alterations of fibrin generation in dogs with haemangiosarcoma using resonance thrombography. The second objective was to evaluate the sensitivity of this method for the detection of hypofibrinogenaemia and/or increased fibrin(ogen) degradation product (FDP) concentration. Resonance thrombogram (RTG) measurements with two different instruments were performed in 30 unselected dogs with haemangiosarcoma, 14 of which had decreased fibrinogen and 28 of which had an increased FDP concentration (p<0.0001). The RTG-reaction time was less sensitive than the fibrin formation time (RTG-f) and fibrin amplitude (RTG-F). The RTG-f and RTG-F indicated reliably a decrease in fibrinogen concentration (sensitivity: 0.93). The sensitivity of detection of increased FDP levels was considerably higher than that of thrombin time. However, false-negative results were found even at FDP concentrations > or =120 mg/l, especially in cases with high fibrinogen level. Both machines showed similar sensitivity. The results of this study indicate that canine haemangiosarcoma is frequently associated with severe alterations of fibrin generation due to low fibrinogen and high FDP levels leading to distinct RTG abnormalities. The global test RTG reacts sensitively to a decreased fibrinogen level whereas its accuracy to detect FDP concentrations occurring under pathophysiological conditions is limited. A significant alteration of fibrin generation induced by FDPs may not occur until the serum FDP concentration exceeds 60 mg/l.
Cosemans, Judith M. E. M.; Schols, Saskia E. M.; Stefanini, Lucia; de Witt, Susanne; Feijge, Marion A. H.; Hamulyák, Karly; Deckmyn, Hans; Bergmeier, Wolfgang
2011-01-01
A microscopic method was developed to study the role of platelets in fibrin formation. Perfusion of adhered platelets with plasma under coagulating conditions at a low shear rate (250−1) resulted in the assembly of a star-like fibrin network at the platelet surface. The focal fibrin formation on platelets was preceded by rises in cytosolic Ca2+, morphologic changes, and phosphatidylserine exposure. Fibrin formation was slightly affected by αIIbβ3 blockage, but it was greatly delayed and reduced by the following: inhibition of thrombin or platelet activation; interference in the binding of von Willebrand factor (VWF) to glycoprotein Ib/V/IX (GpIb-V-IX); plasma or blood from patients with type 1 von Willebrand disease; and plasma from mice deficient in VWF or the extracellular domain of GpIbα. In this process, the GpIb-binding A1 domain of VWF was similarly effective as full-length VWF. Prestimulation of platelets enhanced the formation of fibrin, which was abrogated by blockage of phosphatidylserine. Together, these results show that, in the presence of thrombin and low shear flow, VWF-induced activation of GpIb-V-IX triggers platelet procoagulant activity and anchorage of a star-like fibrin network. This process can be relevant in hemostasis and the manifestation of von Willebrand disease. PMID:21037087
A novel platelet concentrate: titanium-prepared platelet-rich fibrin.
Tunalı, Mustafa; Özdemir, Hakan; Küçükodacı, Zafer; Akman, Serhan; Yaprak, Emre; Toker, Hülya; Fıratlı, Erhan
2014-01-01
We developed a new product called titanium-prepared platelet-rich fibrin (T-PRF). The T-PRF method is based on the hypothesis that titanium may be more effective in activating platelets than the silica activators used with glass tubes in Chouckroun's leukocyte- and platelet-rich fibrin (L-PRF) method. In this study, we aimed to define the structural characteristics of T-PRF and compare it with L-PRF. Blood samples were collected from 10 healthy male volunteers. The blood samples were drawn using a syringe. Nine milliliters was transferred to a dry glass tube, and 9 mL was transferred to a titanium tube. Half of each clot (i.e., the blood that was clotted using T-PRF or L-PRF) was processed with a scanning electron microscope (SEM). The other half of each clot was processed for fluorescence microscopy analysis and light microscopy analysis. The T-PRF samples seemed to have a highly organized network with continuous integrity compared to the other L-PRF samples. Histomorphometric analysis showed that T-PRF fibrin network covers larger area than L-PRF fibrin network; also fibrin seemed thicker in the T-PRF samples. This is the first human study to define T-PRF as an autogenous leukocyte- and platelet-rich fibrin product. The platelet activation by titanium seems to offer some high characteristics to T-PRF.
The effects of scaffold architecture and fibrin gel addition on tendon cell phenotype.
Pawelec, K M; Wardale, R J; Best, S M; Cameron, R E
2015-01-01
Development of tissue engineering scaffolds relies on careful selection of pore architecture and chemistry of the cellular environment. Repair of skeletal soft tissue, such as tendon, is particularly challenging, since these tissues have a relatively poor healing response. When removed from their native environment, tendon cells (tenocytes) lose their characteristic morphology and the expression of phenotypic markers. To stimulate tendon cells to recreate a healthy extracellular matrix, both architectural cues and fibrin gels have been used in the past, however, their relative effects have not been studied systematically. Within this study, a combination of collagen scaffold architecture, axial and isotropic, and fibrin gel addition was assessed, using ovine tendon-derived cells to determine the optimal strategy for controlling the proliferation and protein expression. Scaffold architecture and fibrin gel addition influenced tendon cell behavior independently in vitro. Addition of fibrin gel within a scaffold doubled cell number and increased matrix production for all architectures studied. However, scaffold architecture dictated the type of matrix produced by cells, regardless of fibrin addition. Axial scaffolds, mimicking native tendon, promoted a mature matrix, with increased tenomodulin, a marker for mature tendon cells, and decreased scleraxis, an early transcription factor for connective tissue. This study demonstrated that both architectural cues and fibrin gel addition alter cell behavior and that the combination of these signals could improve clinical performance of current tissue engineering constructs.
Cytotoxic T Lymphocyte Trafficking and Survival in an Augmented Fibrin Matrix Carrier
Zou, Zhaoxia; Denny, Erin; Brown, Christine E.; Jensen, Michael C.; Li, Gang; Fujii, Tatsuhiro; Neman, Josh; Jandial, Rahul; Chen, Mike
2012-01-01
Cell-based therapies have intriguing potential for the treatment of a variety of neurological disorders. One such example is genetically engineered cytotoxic T lymphocytes (CTLs) that are being investigated in brain tumor clinical trials. The development of methods for CTL delivery is critical to their use in the laboratory and clinical setting. In our study, we determined whether CTLs can migrate through fibrin matrices and if their migration, survival, and function could be modulated by adding chemokines to the matrix. Our results indicated that CTLs can freely migrate through fibrin matrices. As expected, the addition of the monocyte chemotactic protein-1 (MCP-1), also known as chemokine C-C motif ligand 2 (CCL2), to the surrounding media increased egress of the CTLs out of the fibrin clot. Interleukin (IL) -2 and/or IL-15 embedded in the matrix enhanced T cell survival and further promoted T cell migration. The interleukin-13 receptor alpha 2 specific (IL-13R alpha2) T cells that traveled out of the fibrin clot retained the capacity to kill U251 glioma cells. In summary, CTLs can survive and migrate robustly in fibrin matrices. These processes can be influenced by modification of matrix constituents. We conclude that fibrin matrices may be suitable T cell carriers and can be used to facilitate understanding of T cell interaction with the surrounding microenvironment. PMID:22496835