Wang, You-Yuan; Fan, Song; Zhang, Han-Qing; Lin, Zhao-Yu; Ye, Jian-Tao; Li, Jin-Song
2016-06-01
Reconstruction of maxillary and midfacial defects due to tumor ablation is challenging to conventional operation. The purposes of this study are to evaluate the precise 3-dimensional position of the fibular flap in reconstruction of maxillary defects assisted by virtual surgical planning and to assess the postoperative outcomes compared with conventional surgery. We retrospectively reviewed 18 consecutive patients who underwent maxillary reconstruction with a vascularized fibular flap assisted by virtual surgical planning after maxillary or midfacial tumor ablation. Conventional surgery was performed in another 15 patients. Proplan CMF surgical planning (Materialise, Leuven, Belgium) was performed preoperatively in the virtual planning group. Fibular flaps were harvested and underwent osteotomy assisted by prefabricated cutting guides, and the maxilla and midface were resected and reconstructed assisted by the prefabricated cutting guides and templates in the virtual planning group. The operative time and fibular flap positions were evaluated in the 2 groups. Postoperative fibular positions of the maxillary reconstruction were compared with virtual plans in the virtual planning group. The postoperative facial appearance and occlusal function were assessed. The operations were performed successfully without complications. The ischemia time and total operative time were shorter in the virtual planning group than those in the conventional surgery group (P < .05). High precision of the cutting guides and templates was found on both the fibula and maxilla in the virtual planning group. The positions of the fibular flaps, including the vertical and horizontal positions, were more accurate in the virtual planning group than those in the conventional surgery group (P < .05). Bone-to-bone contact between the maxilla and fibular segments was more precise in the virtual planning group (P < .05). Postoperative computed tomography scans showed excellent contour of the fibular flap segments in accordance with the virtual plans in the virtual planning group. All patients were alive with no evidence of disease. Functional mandibular range of motion, good occlusion, and an ideal facial appearance were observed in the virtual planning group. Virtual surgical planning appears to achieve precise maxillary reconstruction with a vascularized fibular flap after tumor ablation, as well as an ideal facial appearance and function after dental rehabilitation. The use of prefabricated cutting guides and plates eases fibular flap molding and placement, minimizes operating time, and improves clinical outcomes. Copyright © 2016 The American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Lykoudis, Efstathios G; Dimitrios, Pafilas; Alexandros, Beris E
2010-01-01
Complex midfoot defects represent a reconstructive challenge since midfoot plays a key role in standing and gait. We report the case of a 27-year-old patient with a complex midfoot defect due to a high-energy gun shot injury. The defect included the tarsometatarsal complex, all three arches of the foot, and the overlying dorsal skin of the foot. Reconstruction was achieved in a single stage with a free fibular osteocutaneous flap. The fibula was osteotomized into three segments, which were used to reconstruct the bone defects, while the skin paddle of the flap was used for stable soft tissue coverage of the reconstructed bony skeleton. Early and late postoperative periods were uneventful. Bone incorporation was radiographically evident at 12 weeks, and full weight bearing was possible at 6 months postop. Final follow up, at 2 years postop, showed a very good functional and esthetic outcome.
Limb reconstruction with vascularized fibular grafts after bone tumor resection.
Brown, K L
1991-01-01
Limb-salvage operations are being used with increasing frequency for patients with malignant bone tumors. For children, when a biologic reconstruction is desired, the choice is often between conventional and vascularized fibular grafts. An experimental study was performed in dogs to compare the two types of fibular grafts for bridging segmental defects in the radius and ulna. Twenty-six adult dogs were divided into two groups and studied at intervals of two, three, four, six, and 12 months after transplantation. The conventional grafts healed by creeping substitution i.e., they were first partially resorbed before new bone was laid down. In contrast, the vascularized fibulae maintained their normal structure and hypertrophied by subperiosteal new bone formation. The conventional fibulae eventually hypertrophied but much later than the vascularized grafts. The vascularized grafts were stronger at four and six months. Between six and 12 months, both grafts remodeled to resemble the size and shape of the forearm bones they were replacing. These experimental results have influenced the treatment of patients. Vascularized fibular grafts are ideal for diaphyseal defects greater than 10 cm long, especially in very young children, a poorly vascularized bed, or when bone healing is delayed by chemotherapeutic agents. To maximize hypertrophy, an external fixator is used to immobilize the graft rather than a plate, which acts as a stress shield.
Bumbasirević, Marko Z; Lesić, Aleksandar R; Atkinson, Henry Dushan Edward; Tulić, Goran C
2013-01-01
Free vascularized fibular graft is of the greatest importance in the orthopaedics and trauma. Bone, skeletal defects due to the trauma, infections and congenital anomalies could be successfully solved by the free vascularized fibular grafts. In this article the main anatomical data of fibular graft, surgical techniques, indications for the FVFG in the treatment of trauma caused bone defects or its complications -sequels are described.
Ilizarov bone transport versus fibular graft for reconstruction of tibial bone defects in children.
Abdelkhalek, Mostafa; El-Alfy, Barakat; Ali, Ayman M
2016-11-01
The aim of this study was to compare the results of treatment of segmental tibial defects in the pediatric age group using an Ilizarov external fixator versus a nonvascularized fibular bone graft. This study included 24 patients (age range from 5.5 to 15 years) with tibial bone defects: 13 patients were treated with bone transport (BT) and 11 patients were treated with a nonvascularized fibular graft (FG). The outcome parameters were bone results (union, deformity, infection, leg-length discrepancy) and functional results: external fixation index and external fixation time. In group A (BT), one patient developed refracture at the regenerate site, whereas, in group B (FG), after removal of the external fixator, one of the FGs developed a stress fracture. The external fixator time in group A was 10.7 months (range 8-14.5) versus 7.8 months (range 4-11.5 months) in group B (FG). In group A (BT), one patient had a limb-length discrepancy (LLD), whereas, in group B (FG), three patients had LLD. The functional and bone results of the Ilizarov BT technique were excellent in 23.1 and 30.8%, good in 38.5 and 46.2, fair in 30.8 and 15.4, and poor in 7.6 and 7.6%, respectively. The poor functional result was related to the poor bone result because of prolonged external fixator time resulting in significant pain, limited ankle motion, whereas the functional and bone results of fibular grafting were excellent in 9.1 and 18.2%, good in 63.6 and 45.5%, fair in 18.2 and 27.2%, and poor in 9.1 and 9.1%, respectively. Segmental tibial defects can be effectively treated with both methods. The FG method provides satisfactory results, with early removal of the external fixator. However, it had a limitation in patients with severe infection and those with LLD. Also, it requires a long duration of limb bracing until adequate hypertrophy of the graft. The Ilizarov method has the advantages of early weight bearing, treatment of postinfection bone defect in a one-stage surgery, and the possibility to treat the associated LLD. However, it has a long external fixation time.
Qi, Yong; Sun, Hong-Tao; Fan, Yue-Guang; Li, Fei-Meng; Lin, Zhou-Sheng
2016-06-01
The presence of large segmental defects of the diaphyseal bone is challenging for orthopedic surgeons. Free vascularized fibular grafting (FVFG) is considered to be a reliable reconstructive procedure. Stress fractures are a common complication following this surgery, and hypertrophy is the main physiological change of the grafted fibula. The exact mechanism of hypertrophy is not completely known. To the best of our knowledge, no studies have examined the possible relationship between stress fractures and hypertrophy. We herein report three cases of patients underwent FVFG. Two of them developed stress fractures and significant hypertrophy, while the remaining patient developed neither stress fractures nor significant hypertrophy. This phenomenon indicates that a relationship may exist between stress fractures and hypertrophy of the grafted fibula, specifically, that the presence of a stress fracture may initiate the process of hypertrophy.
Huang, Shih-Tsai; Liu, Wen-Chung; Chen, Lee-Wei; Yang, Kuo-Chung
2015-05-01
Synchronous double oral cancer represents the minority of cases of head and neck cancer. After tumor ablation, 2 separate oromandibular defects, even combined with a through-and-through oral defect, pose a serious reconstructive challenge. The ideal method for reconstruction remains controversial. Based on the peroneal vessel axis, a chimeric double-skin paddle peroneal fasciocutaneous or fibular osteomyocutaneous flap could be designed to accomplish the difficult reconstruction. Six male patients, each with 2 separate oromandibular defects after tumor ablation of synchronous double oral cancer, received double-skin paddle flap reconstruction with 3 peroneal fasciocutaneous and 3 fibular osteomyocutaneous flaps. All 6 flaps survived; however, complications included 1 skin paddle lost due to insufficient perfusion of a visible perforator, and 1 superficial necrosis occurring over the tip of a longer skin paddle. One postoperative intraoral infection and 1 donor site infection were also reported. During follow-up, 3 months later, 1 patient succumbed to local recurrence and bony metastasis. One patient developed a new cancer in the maxillary gingiva, and another had osteoradionecrosis 8 months later. Four patients gained acceptable cosmesis with good oral competence. A chimeric flap based on the peroneal artery could provide a segment of fibular bone, 1 or 2 skin paddles, and a cuff of the flexor hallucis longus muscle simultaneously. For 1-stage reconstruction of separate oromandibular defects after tumor ablation of synchronous double oral cancer, this design could provide all components at 1 transfer.
Yoon, Hyung-In
2016-10-01
This report is to present the treatment procedure and clinical considerations of prosthodontic management of a patient who had undergone a partial mandibulectomy and fibular free flap surgery. A 59-year-old man with a squamous cell carcinoma received a partial mandibular resection. Microsurgical reconstruction with a fibular free flap surgery and implant-supported zirconia-fixed prosthesis produced by computer-aided manufacturing led to successful results for the oral rehabilitation of mandibular defects. The implant-supported zirconia-fixed prosthesis can be recommended for use in patients with mandibulectomy and fibular free flaps. Close cooperation between the surgeon and the prosthodontist is mandatory for the satisfaction of the patient.
2013-01-01
Introduction Free vascularized fibular grafts have been widely used for the reconstruction of long bone defects. However, the use of a vascularized tibial graft is precluded by its weight-bearing function and unacceptable donor site morbidity. Case presentation We present a rare case of using a vascularized tibia-fibular composite graft taken from a 6-year-old Chinese boy’s ipsilateral lower leg to reconstruct a large bony defect of his traumatic femur. Hypertrophy of the tibial graft, good remodeling of the femoral shaft, and atrophy of the unloaded fibular graft were noted at the 10-year follow up. He was able to participate in outdoor activities such as basketball while wearing his prosthesis. Conclusions The 10-year follow up demonstrates the feasibility of this salvage procedure for a floating knee injury with neurovascular compromise. PMID:23714102
Zhang, Lei; Sun, Hao; Yu, Hong-bo; Yuan, Hao; Shen, Guo-fang; Wang, Xu-dong
2013-05-01
Maxillectomy in childhood not only causes composite primary defects but also secondary malformation of the middle and lower face. In the case presented, we introduced computer-assisted planning and simulation of orthognathic surgery combined with fibular osteomyocutaneous flap reconstruction to correct complex craniofacial deformities. Virtual orthognathic surgery and maxillary reconstruction surgery were undertaken preoperatively. LeFort I osteotomy, with bilateral sagittal split ramus osteotomy and lower border ostectomy, was performed to correct malocclusion and facial asymmetry. Maxillary reconstruction was accomplished using a fibular osteomyocutaneous flap. The patient recovered uneventfully with an adequate aesthetic appearance on 3D computed tomography. Our experience indicates that orthognathic surgery combined with fibular osteomyocutaneous flap reconstruction can used to correct complex facial asymmetry and maxillary defects secondary to maxillectomy. Computer-assisted simulation enables precise execution of the reconstruction. It shortens the free flap ischemia time and reduces the risks associated with microsurgery.
Battaglia, Salvatore; Maiolo, Vincenzo; Savastio, Gabriella; Zompatori, Maurizio; Contedini, Federico; Antoniazzi, Elisa; Cipriani, Riccardo; Marchetti, Claudio; Tarsitano, Achille
2017-10-01
Mandibular reconstruction performed after virtual planning has become more common during recent years. The gold standard for extensive mandibular reconstruction is of course a fibular free flap. In designing an osteomyocutaneous fibula flap, poor planning, aberrant anatomy and/or inadequate perforator vessels are the most frequent causes of complications and may force the surgeon to modify the flap design, explore the contralateral leg or harvest an additional microvascular flap. The goal of our study was to pre-operatively evaluate the vascular anatomy of the fibula and localize the cutaneous perforator vessels, so to create the fibular cutting guide based on the position of the cutaneous perforator and safely harvest the reconstructive flap. Twenty consecutive patients who were candidates for mandibular reconstruction using a fibular microvascular free flap were enrolled in this study between January 2016 and August 2016. The patients were preoperatively assessed with a Computed Tomographic scan of head and neck and with a Computed Tomographic Angiography (CTA) scan of the lower limbs to evaluate the vascular anatomy of the fibula. Virtual planning was carried out for all patients. The fibular cutting guide was based on the position of the perforator cutaneous vessels, which were used to harvest the cutaneous part of the flap. Preoperative CT measurements were performed in order to identify the cutaneous perforators on the patients' skin. Intraoperative checking was performed to evaluate the accuracy of the perforators' position and the reproducibility of the virtual planning. In 5 patients out of 20 (25%), anatomical anomalies were discovered, without clinical evidence. The perforator vessels were localized in all patients. The average difference between the CTA and the intraoperative perforator localization was 1 mm (range 0-2 mm). Fibular cutting guide was positioned and fitted the anatomy of the patients in all treated patients. This allowed us to perform the planned segmentation of the fibula, obtaining the correct number of segments. In all cases, flap insetting was carried out and skin paddle was positioned as preoperatively planned. Neither donor site complications nor flap complications occurred. Preoperative evaluation of the legs using CTA, in patients who undergo an osteomyocutaneous fibular free flap for mandibular reconstruction, is a valuable approach to reduce altered-anatomy related complications and to improve the accuracy and outcomes of the reconstruction, especially in reconstructions of complex defects. In these cases, a soft tissue-based cutting guide can be planned based on the perforator vessels of the skin paddle, minimizing the harvesting risks of vascular lesions. Further studies and longer follow-ups are needed to evaluate the long-term outcomes and advantages of this procedure. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Gurunluoglu, Raffi; Glasgow, Mark; Williams, Susan A; Gurunluoglu, Aslin; Antrobus, Jarod; Eusterman, Vincent
2012-10-01
Reconstruction of total full-thickness lower lip defects combined with extensive composite mandibular defects particularly in the setting of close-range high-energy ballistic injury presents a formidable challenge for the reconstructive plastic surgeon. While the fibular flap has been widely accepted for its usefulness in the reconstruction of composite mandibular defects, to date, there is no definitive widely established method of total lower lip reconstruction. The article presents authors' approach using innervated gracilis muscle flap for total lower lip reconstruction in the setting of high-energy gunshot injuries to the face. Three patients underwent composite mandibular defect reconstruction using fibular osteocutaneous flap and functional lower lip reconstruction using innervated gracilis muscle flap. Lip lining was reconstructed using the skin paddle of the fibular flap. The external surface of the gracilis muscle was skin-grafted. Facial artery myomucosal flap provided vermilion reconstruction in two patients. All fibular (n=3) and gracilis flap transfers (n=3) were viable. An electromyographic study at 1 year postoperatively demonstrated successful re-innervation of the gracilis muscle. Starting at about 10 weeks postoperatively, patients exhibited voluntary lip movements and oral competence. In addition, all patients achieved near-normal speech, evidence of recovered protective sensitivity and satisfactory appearance. The mean follow-up was 16.1 months. Our preliminary report in three patients demonstrated that innervated gracilis muscle transfer combined with fibular flap provides a successful reconstruction of extensive composite mandibular and total lower lip defects resulting from gunshot injuries to the face. Oral continence was achieved by combination of regained tonicity and voluntary movement of the gracilis muscle following re-innervation and assistance of the cheek muscles on the gracilis muscle. The described technique was reliable and the results were promising. Copyright © 2012 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Shan, Xiao-Feng; Li, Ru-Huang; Lu, Xu-Guang; Cai, Zhi-Gang; Zhang, Jie; Zhang, Jian-Guo
2015-03-01
Fibular osteoseptocutaneous flap has been widely used for unilateral mandibular reconstruction. However, reports about the effects of fibular osteoseptocutaneous flap for the reconstruction of bilateral mandibular defects are limited. In this study, we used free vascularized fibular flaps to successfully manage bilateral mandibular osteoradionecrosis(ORN) in 5 patients. Functional aspects were evaluated during the reconstruction process. All 5 patients had bilateral refractory ORN of the mandible and underwent radical resection between 2003 and 2011. The reconstruction surgery was performed in 2 stages using 2 free fibular flaps in 3 patients. In the other 2 patients, reconstruction was performed in a single stage using 2 separate flaps prepared from a single fibula. All patients had a healthy mandibular symphysis and meniscus of the temporomandibular joint, and these structures were preserved during the reconstruction.Of the 10 defects involving the mandible sides, 9 were successfully reconstructed. One microvascular composite flap failed because of radiation injury to the arterial endothelium at the recipient site. After the treatments, all patients had good esthetic and functional outcomes. Preoperative clinical features such as trismus and dysphagia were also markedly improved. Our surgical method may be an effective alternative for the clinical management of advanced bilateral mandibular ORN.
Tsai, Ming-June; Wu, Ching-Tsai
2014-05-06
This study aimed to establish surgical guiding techniques for completing mandible lesion resection and reconstruction of the mandible defect area with fibula sections in one surgery by applying additive manufacturing technology, which can reduce the surgical duration and enhance the surgical accuracy and success rate. A computer assisted mandible reconstruction planning (CAMRP) program was used to calculate the optimal cutting length and number of fibula pieces and design the fixtures for mandible cutting, registration, and arrangement of the fibula segments. The mandible cutting and registering fixtures were then generated using an additive manufacturing system. The CAMRP calculated the optimal fibula cutting length and number of segments based on the location and length of the defective portion of the mandible. The mandible cutting jig was generated according to the boundary surface of the lesion resection on the mandible STL model. The fibular cutting fixture was based on the length of each segment, and the registered fixture was used to quickly arrange the fibula pieces into the shape of the defect area. In this study, the mandibular lesion was reconstructed using registered fibular sections in one step, and the method is very easy to perform. The application of additive manufacturing technology provided customized models and the cutting fixtures and registered fixtures, which can improve the efficiency of clinical application. This study showed that the cutting fixture helped to rapidly complete lesion resection and fibula cutting, and the registered fixture enabled arrangement of the fibula pieces and allowed completion of the mandible reconstruction in a timely manner. Our method can overcome the disadvantages of traditional surgery, which requires a long and different course of treatment and is liable to cause error. With the help of optimal cutting planning by the CAMRP and the 3D printed mandible resection jig and fibula cutting fixture, this all-in-one process of mandible reconstruction furnishes many benefits in this field by enhancing the accuracy of surgery, shortening the operation duration, reducing the surgical risk, and resulting in a better mandible appearance of the patients after surgery.
2014-01-01
Background This study aimed to establish surgical guiding techniques for completing mandible lesion resection and reconstruction of the mandible defect area with fibula sections in one surgery by applying additive manufacturing technology, which can reduce the surgical duration and enhance the surgical accuracy and success rate. Methods A computer assisted mandible reconstruction planning (CAMRP) program was used to calculate the optimal cutting length and number of fibula pieces and design the fixtures for mandible cutting, registration, and arrangement of the fibula segments. The mandible cutting and registering fixtures were then generated using an additive manufacturing system. The CAMRP calculated the optimal fibula cutting length and number of segments based on the location and length of the defective portion of the mandible. The mandible cutting jig was generated according to the boundary surface of the lesion resection on the mandible STL model. The fibular cutting fixture was based on the length of each segment, and the registered fixture was used to quickly arrange the fibula pieces into the shape of the defect area. In this study, the mandibular lesion was reconstructed using registered fibular sections in one step, and the method is very easy to perform. Results and conclusion The application of additive manufacturing technology provided customized models and the cutting fixtures and registered fixtures, which can improve the efficiency of clinical application. This study showed that the cutting fixture helped to rapidly complete lesion resection and fibula cutting, and the registered fixture enabled arrangement of the fibula pieces and allowed completion of the mandible reconstruction in a timely manner. Our method can overcome the disadvantages of traditional surgery, which requires a long and different course of treatment and is liable to cause error. With the help of optimal cutting planning by the CAMRP and the 3D printed mandible resection jig and fibula cutting fixture, this all-in-one process of mandible reconstruction furnishes many benefits in this field by enhancing the accuracy of surgery, shortening the operation duration, reducing the surgical risk, and resulting in a better mandible appearance of the patients after surgery. PMID:24885749
Santos, Silvana C; Pardono, Eliete; Ferreira da Costa, Maria Ione; de Melo, Aurea Nogueira; Graciani, Zodja; de Albuquerque e Souza, Alessandra Cavalcanti; Lezirovitz, Karina; Thiele-Aguiar, Renata Soares; Mingroni-Netto, Regina Célia; Opitz, John M; Kok, Fernando; Otto, Paulo A
2008-12-15
We describe an apparently new genetic syndrome in six members of a family living in a remote area in Northeastern Brazil. This syndrome comprises: short stature due to a marked decrease in the length of the lower limbs (predominantly mesomelic with fibular agenesis/marked hypoplasia), grossly malformed/deformed clubfeet with severe oligodactyly, upper limbs with acromial dimples and variable motion limitation of the forearms and/or hands, severe nail hypoplasia/anonychia sometimes associated with mild brachydactyly and occasionally with pre-axial polydactyly. This syndrome is apparently distinct from the syndrome of brachydactyly-ectrodactyly with fibular aplasia or hypoplasia (OMIM 113310), the syndrome of fibular aplasia or hypoplasia, femoral bowing and poly-, syn-, and oligodactyly (OMIM 228930), and from other previously described conditions exhibiting fibular agenesis/hypoplasia. Copyright (c) 2008 Wiley-Liss, Inc.
Lesiak, Alex C; Esposito, Paul W
2014-06-01
The fibula is an important stabilizer of the lateral ankle. Discontinuity of the fibular shaft can lead to progressive pain and shortening of the fibula, ultimately causing loss of lateral support to the ankle. Two children, who sustained segmental bone loss of the shaft of the fibula, developed progressive symptomatic valgus of the ankle with widening of the mortice and lateral subluxation of the talus. Both patients were treated with fibular plating and grafting with tricalcium sulfate with acute reconstitution of fibular length. Distal medial tibial hemiepiphysiodesis was simultaneously performed. One patient required revision plating and grafting 14 months after the index surgery because of plate failure. The valgus angulation and the widened medial mortice were corrected in the ankles of both patients, who returned to full activities. The patients were followed to maturity; the correction has been maintained, and they remain asymptomatic. The technique used in these cases can correct valgus angulation secondary to loss of fibular congruity rather than only halting progression of the deformity.
Xu, Y Q; Li, Z Y; Li, J
2000-11-01
To investigate the clinical effect of free vascularized thoracoumbilical flap with reversal flow in repairing the soft tissue defect in leg with tibia exposure. Forty-four casting mould specimens of leg arteries were studied firstly. Then 25 cases with soft tissue defect and tibia exposure in the proximal-middle segment of leg were adopted in this study. Among them, 18 cases had long distance thrombosis of the anterior tibial vessels or posterior tibial vessels due to traumatic lesion. The maximal size of defect was 28 cm x 11 cm and the minimal size of defect was 11 cm x 9 cm. In operation, the thoracoumbilical flap which was based on the inferior epigastric vessels was anastomosed to the distal end of the anterior tibial vessels or posterior tibial vessels. Anterior tibial artery, posterior tibial artery and fibular artery had rich communication branches in foot and ankle. All the flaps survived, the color and cosmetic result of them were good. The free vascularized thoracoumbilical flap with reversed flow is practical in repairing the soft tissue defect of leg with tibia exposure. Either the anterior tibial vessels or the posterior tibial vessels is normal, and the distal end of injured blood vessels is available, this technique can be adopted.
Yang, Yun-fa; Xu, Zhong-he; Zhang, Guang-ming; Wang, Jian-wei; Hu, Si-wang; Hou, Zhi-qi; Xu, Da-chuan
2013-11-01
Posttraumatic infected massive bone defects in lower extremities are difficult to repair because they frequently exhibit massive bone and/or soft tissue defects, serious bone infection, and excessive scar proliferation. This study aimed to determine whether these defects could be classified and repaired at a single stage. A total of 51 cases of posttraumatic infected massive bone defect in lower extremity were included in this study. They were classified into four types on the basis of the conditions of the bone defects, soft tissue defects, and injured limb length, including Type A (without soft tissue defects), Type B (with soft tissue defects of 10 × 20 cm or less), Type C (with soft tissue defects of 10 × 20 cm or more), and Type D (with the limb shortening of 3 cm or more). Four types of single-stage microsurgical repair protocols were planned accordingly and implemented respectively. These protocols included the following: Protocol A, where vascularized fibular graft was implemented for Type A; Protocol B, where vascularized fibular osteoseptocutaneous graft was implemented for Type B; Protocol C, where vascularized fibular graft and anterior lateral thigh flap were used for Type C; and Protocol D, where limb lengthening and Protocols A, B, or C were used for Type D. There were 12, 33, 4, and 2 cases of Types A, B, C, and D, respectively, according to this classification. During the surgery, three cases of planned Protocol B had to be shifted into Protocol C; however, all microsurgical repairs were completed. With reference to Johner-Wruhs evaluation method, the total percentage of excellent and good results was 82.35% after 6 to 41 months of follow-up. It was concluded that posttraumatic massive bone defects could be accurately classified into four types on the basis of the conditions of bone defects, soft tissue coverage, and injured limb length, and successfully repaired with the single-stage repair protocols after thorough debridement. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Effect of hip and knee position on nerve conduction in the common fibular nerve.
Broadhurst, Peter Kaas; Robinson, Lawrence R
2017-09-01
The aim of this study was to measure the influence that hip and knee position have on routine fibular motor nerve conduction studies. Healthy subjects under age 40 were recruited (n = 24) to have fibular nerve conduction studies completed in various positions, using hip extension-knee extension as a control. A mean increase in conduction velocity of 2.5 m/s across the knee (P = 0.020) was seen during hip flexion compared with hip extension. A mean decrease in velocity of 1.6 m/s through the leg segment (P = 0.016) was seen during knee flexion compared with knee extension. This study shows that the optimal position of the leg during fibular nerve studies is with the hip in flexion and knee in extension, to more accurately reflect nerve length for velocity calculations. This may have implications for other peripheral nerves with respect to proximal joint position affecting calculated velocity. Muscle Nerve 56: 519-521, 2017. © 2017 Wiley Periodicals, Inc.
Bucur, A; Dincă, O; Totan, C; Ghită, V
2007-01-01
The optimal reconstruction of the mandible and of the temporo-mandibular joint after mandibular hemi-resection with disarticulation is still controversial in literature. This paperwork presents our experience on four cases in the reconstruction of the mandible together with the inferior arthroplasty of the temporo-mandibular joint, after the resection of extended benign tumors of the mandible, based on fibular free vascularized grafts having attached a Stryker titanium condylar prosthesis reconstructing the inferior segment of the temporo-mandibular joint. Our results for the this technique were excellent, with a functional rehabilitation very close to normal. After reviewing the various techniques and their arguments in literature, with accent on the TMJ reconstruction, we consider this method to be optimal for the reconstruction of mandibular defects in patients with neoplastic conditions.
A-Frame free Vascularized Fibular Graft and Femoral Lengthening for Osteosarcoma Pediatric Patients.
Cashin, Megan; Coombs, Christopher; Torode, Ian
2018-02-01
Pediatric limb reconstruction after resection of a malignant tumor presents specific challenges. Multiple surgical techniques have been used to treat these patients. This paper describes a staged surgical technique for the reconstruction of large distal femoral defects due to tumor resection in skeletally immature patients. Three pediatric patients with osteosarcoma of the distal femur underwent staged reconstruction. Neoadjuvant chemotherapy was followed by en bloc tumor resection and immediate reconstruction of the distal femoral defect with a vascularized free fibular autograft utilizing a unique A-frame construct combined with intramedullary nail fixation. The second stage was a planned gradual lengthening of the healed construct, over a custom-made magnetically driven expandable intramedullary nail. All patients achieved bony union and satisfactory length with minimal complications. The patients all returned to full, unlimited physical activities. The early results confirm that the described technique is a safe and reliable procedure for the reconstruction of large femoral defects in pediatric patients with osteosarcoma. Level IV-therapeutic.
Arthrodesis Using Pedicled Fibular Flap After Failed Infected Knee Arthroplasty
Minear, Steve C.; Lee, Gordon; Kahn, David; Goodman, Stuart
2011-01-01
Objective: Severe bone loss associated with failed revision total knee arthroplasty is a challenging scenario. The pedicled fibular flap is a method to obtain vascularized bone for use in knee arthrodesis after failure of a total knee arthroplasty, with substantial loss of bone. Methods: We report 2 successful knee arthrodeses using this method in patients with infected, failed multiply revised total knee arthroplasties. The failed prosthesis was removed, and the bones were aligned and stabilized. The fibular flap was then harvested, fed through a subcutaneous tunnel, and placed within the medullary canal at the arthrodesis site. The soft tissue was closed over the grafts and flaps. Results: Two elderly women presented with pain and drainage from previous total knee arthroplasties after multiple revisions. Arthrodeses were performed as described, and both patients were pain-free with the knee fused at 1 year. Conclusions: Thus, pedicled vascularized flaps are a viable alternative in the treatment of failed revision arthroplasty with large segmental bone loss. PMID:22132250
Chen, Szu-Han; Hung, Kuo-Shu; Lee, Yao-Chou
2017-05-01
Maxillary reconstruction using titanium mesh or bone grafts can invite unwanted complications, such as graft resorption, infection, and mesh exposure, especially for patients who require postoperative radiotherapy. Here, we reported a 58-year-old male patient who was diagnosed with maxillary sinus squamous cell carcinoma. The patient received cancer ablation by a globe-sparing total maxillectomy and was immediately reconstructed with a double-barrel osteocutaneous fibular flap to simultaneously restore the alveolar ridge, orbital support, and oro-sinonasal separation. The short pedicle length inherent in the double-barrel design of the fibular flap and the depletion of healthy recipient vessels in the midface after cancer ablation were overcome by creating an arteriovenous saphenous loop in the neck region. Though there was venous congestion on postoperative day 2, the postoperative recovery was uneventful after the revision of the venous anastomoses. During the 6-months follow-up, the outcome was functionally and aesthetically satisfactory. We believe that the double-barrel fibular osteocutaneous flap, which avoids using titanium mesh and bone grafts, may be a viable reconstructive option in cancer patients with globe-sparing total maxillectomy defects, especially for those who require postoperative radiotherapy. © 2015 Wiley Periodicals, Inc. Microsurgery 37:334-338, 2017. © 2015 Wiley Periodicals, Inc.
Xie, Wenjun; Zhang, Yu; Qin, Xiaodong; Song, Lijun; Chen, Qun
2018-03-01
High fibular osteotomy has been preliminarily proved to be an effective treatment of knee osteoarthritis by excising a segment of bone at the proximal part of fibula. This imaginative procedure is clinical validated by its instant and explicit knee pain resorption and eventually deformity correction. The rationale of this treatment is named non-uniform settlement of the tibial plateau and used to elucidate the cause of knee joint degeneration, but cannot illuminate the reason of prompt postoperative pain resorption faithfully. To assist in better understanding of this therapeutic method and raising alert to possible unexpected complications, we proposed a new theory to elucidate the pain relief mechanism.
Sanesh, Tuteja; Sachin, Kale; Prasad, Chaudhari; B, Dhar Sanjay
2016-01-01
Giant Cell Tumors commonly occur around the knee joint in the age group of 20-30 years. They are treated with intra-lesional curettage or local resection and limb reconstruction. Management of large bone defects after resection is a challenge and is of ten complicated with non-union of grafts, infection and delayed weight bearing. A 37-year-old male presented with an aggressive recurrent giant cell tumor of the distal femur. He was and was diagnosed with a GCT of the left distal femur 2 years ago for which he was treated with an intralesional curettage and Poly methylmetacrylate implantation. A resection arthrodesis using a bilateral non-vascularised intramedullary fibular graft and a custom made intramedullary nail was performed. The follow-up radiographs showed union at graft-host junction and hypertrophy of the grafted fibula at 2 years post surgery. Non-vascularised fibular graft is an effective alternative for resection arthrodesis with the advantages of a simpler and shorter surgical procedure and without the needs for a microsurgical setup.
Sanesh, Tuteja; Sachin, Kale; Prasad, Chaudhari; Sanjay, B Dhar
2016-01-01
Introduction: Giant Cell Tumors commonly occur around the knee joint in the age group of 20-30 years. They are treated with intra-lesional curettage or local resection and limb reconstruction. Management of large bone defects after resection is a challenge and is of ten complicated with non-union of grafts, infection and delayed weight bearing. Case Presentation: A 37-year-old male presented with an aggressive recurrent giant cell tumor of the distal femur. He was and was diagnosed with a GCT of the left distal femur 2 years ago for which he was treated with an intralesional curettage and Poly methylmetacrylate implantation. A resection arthrodesis using a bilateral non-vascularised intramedullary fibular graft and a custom made intramedullary nail was performed. The follow-up radiographs showed union at graft-host junction and hypertrophy of the grafted fibula at 2 years post surgery. Conclusion: Non-vascularised fibular graft is an effective alternative for resection arthrodesis with the advantages of a simpler and shorter surgical procedure and without the needs for a microsurgical setup. PMID:28116258
Grohmann, Isabella; Raith, Stefan; Mücke, Thomas; Stimmer, Herbert; Rohleder, Nils; Kesting, Marco R; Hölzle, Frank; Steiner, Timm
2015-10-01
Advantages and disadavantages of the three most commonly-used bone grafts for mandibular reconstruction are widely known, but biomechanical experimental studies are rare. We have done loading tests on cadaveric mandibles reconstructed with fibular, iliac crest, and scapular grafts using 3 different osteosynthesis systems to detect and compare their primary stability. Loading tests were done on mandibles with grafts from the fibula and iliac crest and published previously. A 4.5cm paramedian L-type defect was reconstructed with scapula using 2 monocortical non-locking plates, 2 monocortical locking plates, or a single bicortical locking plate/fracture gap in 18 human cadaveric mandibles. These were loaded on to the "Mandibulator" test bench and the movement of fragments in 3 dimensions was assessed and quantified by a PONTOS® optical measurement system. Comparison of the osteosynthesis groups showed that the miniplate was significantly superior to the 6-hole TriLock® plate for both fibular and iliac crest grafts. The fibular graft gave greater stability than the iliac crest and scapular grafts for all 3 osteosynthesis systems. All bony specimens offered sufficient resistance to mechanical stress within the recognised range of biting forces after mandibular reconstruction, independently of the choice of bone graft and osteosynthesis system used. Anatomical and surgical advantages need to be taken into account when choosing a graft. Stability can be maximised with a fibular graft, and further optimised by enlarging the binding area by using the "double barrel" method. Computer simulated experiments could segregate factors that biased results, such as morphological differences among cadavers. Copyright © 2015 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Cornelius, Carl-Peter; Smolka, Wenko; Giessler, Goetz A; Wilde, Frank; Probst, Florian A
2015-06-01
Preoperative planning of mandibular reconstruction has moved from mechanical simulation by dental model casts or stereolithographic models into an almost completely virtual environment. CAD/CAM applications allow a high level of accuracy by providing a custom template-assisted contouring approach for bone flaps. However, the clinical accuracy of CAD reconstruction is limited by the use of prebent reconstruction plates, an analogue step in an otherwise digital workstream. In this paper the integration of computerized, numerically-controlled (CNC) milled, patient-specific mandibular plates (PSMP) within the virtual workflow of computer-assisted mandibular free fibula flap reconstruction is illustrated in a clinical case. Intraoperatively, the bone segments as well as the plate arms showed a very good fit. Postoperative CT imaging demonstrated close approximation of the PSMP and fibular segments, and good alignment of native mandible and fibular segments and intersegmentally. Over a follow-up period of 12 months, there was an uneventful course of healing with good bony consolidation. The virtual design and automated fabrication of patient-specific mandibular reconstruction plates provide the missing link in the virtual workflow of computer-assisted mandibular free fibula flap reconstruction. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Transient recycling of resected bone to facilitate mandibular reconstruction--a technical note.
Lee, Jing-Wei; Tsai, Shin-Sheng; Kuo, Yao-Lung
2006-10-01
Mandibular reconstruction requires considerable sculptural skills. The intriguingly complex configuration of the structure is difficult to reproduce. It is thus imperative for surgeons to seek a technique that improves the precision of the reconstruction. A 55-year-old male presented with a full thickness cancer (T4+) of his left cheek. Radical ablative surgery resulted in an extensive loss of bone and soft tissue mandating major reconstruction. The resected bony specimen was thoroughly denuded, autoclaved, and then placed back into its original site so that the mandible resumed its pre-surgical configuration. A reconstruction plate was applied to maintain structural stability, then the "recycled bone" was used as a template and replaced with a free fibular graft. The patient fared well and a follow-up panoramic radiograph demonstrated good alignment and symmetry of the reconstructed mandible. This method is a viable option for segmental mandibulectomy defect repair in selected cases. Using this technique, it is possible to restore the original bony contour expediently and accurately.
Leg lengthening in patients with congenital fibular hemimelia.
Jasiewicz, Barbara; Kacki, Wojciech; Koniarski, Arkadiusz; Kasprzyk, Marcin; Zarzycka, Maja; Tesiorowski, Maciej
2002-08-30
Background. Anisomelia in patients with congenital fibular deficiencies is a difficult orthopedic problem due to concomitant deformities of the angle and knee. The goal of the present study was to analyze outcomes of tibia lengthening in these patients. Material and methods. In the period 1989-2001 we performed lengthening of 26 limbs in 21 patients with congenital fibular deficiency (11 female, 10 male, average age 10.1 years). Under the Achterman-Kalamchi classification, 8 tibiae were Type 1, 3 were Type 1b, and 10 were Type 2 (including one case with bilateral defect). The average baseline shortening was 4.6 cm, i.e. 15.3%. The Ilizarov method was used in 24 cases, chondrial lengthening in the others. We measured time of lengthening, time of stabilization, total healing time, amount of lengthening, and the lengthening index, as well as the range of ankle and knee movement, the positioning of the foot, and the axis of the tibia at each stage. Problems and complications were classified according to Paley. The average follow-up was 4.9 years Results. The mean time of lengthening was 101 days, stabilization time 177 days, total healing time 269 days, mean lengthening 5.6 cm (22.9%). As of the last examination only 7 patients did not require follow-up surgery, 6 with Type 1a and 1 with Type 1b. Conclusions. Tibia lengthening with axis correction constitutes an alternative to amputation in congenital fibular deficiency. It is a difficult procedure, however, encumbered by a significant risk of complications.
Tuzun, Harun Yasin; Kurklu, Mustafa; Kulahci, Yalcin; Turkkan, Selim; Arsenishvili, Arsen
The heel comprises the epidermis, minimal subcutaneous tissue, a dense septum, and the calcaneus. Injury to any of these structures can impair the ability to walk. The soft tissue or calcaneal bone can be injured by trauma. Injuries incurred in war are usually high-energy traumas caused by weapons such as rifles, rockets, and land mines. Such injuries can be life threatening and involve the loss of tissue, including skin, soft tissue, bone, and neurovascular tissue. Two main treatment protocols are used for such injuries with large tissue defects: amputation and reconstruction. We describe a reconstruction with an osteomyocutaneous fibular flap for a heel injury. At the 2-year follow-up point, the patient had 30% loss of ankle range of motion. The visual analog scale score had dramatically decreased from 8 to 1, and the patient was satisfied with the result. In conclusion, patients with significant problems such as infection, pain, and anatomic deterioration of the calcaneus can be successfully treated using an osteomyocutaneous fibular flap in a single surgery. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Jacobsen, Hans-Christian; Wahnschaff, Falko; Trenkle, Thomas; Sieg, Peter; Hakim, Samer G
2016-01-01
Bony reconstruction of jaw defects using the free fibular flap and dental rehabilitation mostly requires insertion of dental implants within the transferred fibula bone. The aim of this paper was to discuss results of the implant stability with data on the possible benefit for the patient's quality of life after such treatment. For clinical outcome of implants, we evaluated 26 patients with a total number of 94 dental implants after a follow-up period of 12 to 132 months. A group of 38 patients who underwent mandibular reconstruction with free fibular flap could be included in the life-quality study. Evaluation included 23 patients with and 15 patients without implant-borne restoration. The quality of life was assessed using the standard QLQ C-30 questionnaire and the H&N35 module of the European Organisation for Research and Treatment of Cancer (EORTC). Of implants, 94.7 % were stable at the time of investigation and could be used for prosthesis. Patients with dental implants reported improvement of life quality along with better scores in most function and symptom scales; however, only values for global health status (QL2), absence of dyspnea (DY) and absence of feeding tube (HNFE) were significantly better than in the control group. Dental implant insertion in fibula grafts along with implant-borne restoration is a proven concept and might lead to improved quality of life following ablative surgery of the jaw. The effect on the quality of life is not as predictable as on the implant stability. Patients with bony defects of the jaw require bony reconstruction. This allows further masticatory rehabilitation using dental implants and might lead to improved quality of life.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lisbona, R.; Rennie, W.R.J.; Daniel, R.K.
1980-02-01
Free vascularized bone grafting is a new technique applied to the reconstructive surgery of long bones affected by aggressive benign or malignant processes, as well as traumatic deficiencies. These bone lesions may be treated by en bloc excision and replacement with fibular segments or osteocutaneous flaps from the groin isolated on their vascular pedicle. Microvascular anastomosis of the pedicle at the recipient site is necessary. Radionuclide bone imaging is unique in the assessment of the free vascularized bone graft because postoperative graft uptake of radiopharmaceutical reflects patent anastomoses and segmental bone viability.
Wilkman, T; Husso, A; Lassus, P
2018-05-01
This study compared the three most used composite flaps in maxillofacial reconstructions in our institute. Between 2000 and 2012, a total of 163 patients with mandibular, maxillary, and orbital defects received either scapular, fibular, or iliac crest osseal reconstructions in Helsinki University Hospital, Departments of Plastic Surgery and Maxillofacial Surgery. Data regarding the patient demographics, complications, and outcomes were analyzed. There were 92 deep circumflex iliac artery flaps (56%), followed by 42 scapular (26%) and 29 fibular flaps (18%). The rate of flap loss was the highest in the deep circumflex iliac artery group (p = 0.001). Reconstructions using fibula were fastest (p = 0.001) and had lowest perioperative blood loss (p = 0.013). There were no significant differences in the number of early or late complications between the flaps, but donor site complications were more severe in deep circumflex iliac artery. Osteotomies as well as dental implants were safely performed in all flaps with equal results. All three flaps of this study can be performed with awareness of the deep circumflex iliac artery flap being the least reliable alternative. The knowledge of the advantages and disadvantages of several osseal-free flap alternatives is beneficial in selecting the best suitable method for each individual patient requiring maxillofacial osseal reconstruction.
Liu, Yun-feng; Xu, Liang-wei; Zhu, Hui-yong; Liu, Sean Shih-Yao
2014-05-23
The occurrence of mandibular defects caused by tumors has been continuously increasing in China in recent years. Conversely, results of the repair of mandibular defects affect the recovery of oral function and patient appearance, and the requirements for accuracy and high surgical quality must be more stringent. Digital techniques--including model reconstruction based on medical images, computer-aided design, and additive manufacturing--have been widely used in modern medicine to improve the accuracy and quality of diagnosis and surgery. However, some special software platforms and services from international companies are not always available for most of researchers and surgeons because they are expensive and time-consuming. Here, a new technical solution for guided surgery for the repair of mandibular defects is proposed, based on general popular tools in medical image processing, 3D (3 dimension) model reconstruction, digital design, and fabrication via 3D printing. First, CT (computerized tomography) images are processed to reconstruct the 3D model of the mandible and fibular bone. The defect area is then replaced by healthy contralateral bone to create the repair model. With the repair model as reference, the graft shape and cutline are designed on fibular bone, as is the guide for cutting and shaping. The physical model, fabricated via 3D printing, including surgical guide, the original model, and the repair model, can be used to preform a titanium locking plate, as well as to design and verify the surgical plan and guide. In clinics, surgeons can operate with the help of the surgical guide and preformed plate to realize the predesigned surgical plan. With sufficient communication between engineers and surgeons, an optimal surgical plan can be designed via some common software platforms but needs to be translated to the clinic. Based on customized models and tools, including three surgical guides, preformed titanium plate for fixation, and physical models of the mandible, grafts for defect repair can be cut from fibular bone, shaped with high accuracy during surgery, and fixed with a well-fitting preformed locking plate, so that the predesigned plan can be performed in the clinic and the oral function and appearance of the patient are recovered. This method requires 20% less operating time compared with conventional surgery, and the advantages in cost and convenience are significant compared with those of existing commercial services in China. This comparison between two groups of cases illustrates that, with the proposed method, the accuracy of mandibular defect repair surgery is increased significantly and is less time-consuming, and patients are satisfied with both the recovery of oral function and their appearance. Until now, more than 15 cases have been treated with the proposed methods, so their feasibility and validity have been verified.
Lai, Davy; Chen, Chuan-Mu; Chiu, Fang-Yao; Chang, Ming-Chau; Chen, Tain-Hsiung
2007-01-01
We evaluate the effect of reconstructing huge defects (mean, 15.8 cm) of the distal femur with Ilizarov's distraction osteogenesis and free twin-barreled vascularized fibular bone graft (TVFG). We retrospectively reviewed a consecutive series of five patients who had cases of distal femoral fractures with huge defects and infection that were treated by the Ilizarov's distraction osteogenesis. After radical debridement, two of the five cases had free TVFG and monolocal distraction osteogenesis, and another two cases had multilocal distraction osteogenesis with knee fusion because of loss of the joint congruity. The other case with floating knee injury had bilocal distraction osteogenesis and a preserved knee joint. The mean defect of distal femur was 15.8 cm (range, 14-18 cm) in length. The mean length of distraction osteogenesis by Ilizarov's apparatus was 8.2 cm. The mean length of TVFG was 8 cm. The average duration from application of Ilizarov's apparatus to achievement of bony union was 10.2 months (range, 8-13 months). At the end of the follow-up, ranges of motion of three knees were 0 to 45 degrees, 0 to 60 degrees, and 0 to 90 degrees. Two cases had knee arthrodesis with bony fusion because of loss of the joint congruity. There were no leg length discrepancies in all five patients. In addition, three patients had pin tract infections and one case had a 10 degree varus deformity of the femur. Juxta-articular huge defect (>10 cm) of distal femur remains a challenge to orthopedic surgeons. Ilizarov's technique provides the capability to maintain stability, eradicate infection, restore leg length, and to perform adjuvant reconstructive procedure easily. In this study, we found that combining Ilizarov's distraction osteogenesis with TVFG results in improved patient outcome for patients with injuries such as supracondylar or intercondylar infected fractures or nonunion of distal femur with huge bone defect.
Roukis, Thomas S; Kang, Rachel B
2016-01-01
Tibiotalocalcaneal arthrodesis stabilized with retrograde intramedullary nail fixation is associated with a high incidence of complications. This is especially true when performed with a bulk structural allograft and poor soft tissue quality. In select high-risk limb salvage cases, we have augmented tibiotalocalcaneal arthrodesis procedures stabilized using retrograde intramedullary nail fixation with a vascularized pedicled fibular onlay bone graft. We present the data from 10 such procedures with a mean follow-up period of 10.9 ± 5.4 (range 6 to 20) months involving 10 patients (9 males and 1 female). The etiology was avascular osteonecrosis of the talus and/or distal tibia and a resultant large volume cavitary bone defect (8 ankles), severe equinocavovarus contracture (1 ankle), and failed total ankle replacement (1 ankle). A frozen femoral head bulk allograft was used twice, a whole frozen talus allograft once, and a freeze-dried calcaneal allograft once. The fibula was mobilized with intact musculoperiosteal perforating branches of the peroneal artery as a vascularized pedicle onlay bone graft fixated with a screw and washer construct. The mean fibular graft length was 10.2 ± 2.3 cm. The mean interval to radiographic fusion was 2.6 ± 0.6 months and to weightbearing was 3.1 ± 1.4 months. Two stable bulk allograft-host bone and fibular graft-host bone nonunions occurred after intramedullary nail hardware failure. Tibiotalocalcaneal arthrodesis augmented by vascularized pedicled fibular graft stabilized with retrograde compression intramedullary nail fixation offers a reliable option for complex salvage situations when few other options exist. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Guo, Q-F; Xu, Z-H; Wen, S-F; Liu, Q-H; Liu, S-H; Wang, J-W; Li, X-Y; Xu, H-H
2012-09-01
To evaluate the feasibility and reliability of free vascularized fibular graft with skin island flap for reconstruction of large diaphyseal bone defect. The clinical results of vascularized fibular graft and experiences related to the importance and reliability of a monitoring island flap for the reconstruction of various long-bone defects were reviewed in 87 patients. Bony reconstruction was achieved in 82 of the 87 patients. Arterial thrombosis of anastomosed vessel in two patients and venous congestion of monitoring flap in nine patients occurred in the early postoperative periods. All of them were managed by immediate thrombectomy and reanastomosis, alternatively the thrombotic veins were replaced by new veins to anastomose with the superficial veins in five patients. Partial flap necrosis was noted in six patients, but additional surgical intervention was not required. The vascularized fibula survived and bony fusion was achieved in all patients. Postoperative stress fractures of the fibula graft occurred in 19 (21.8%) patients (once in seven patients, twice in five patients, three or more times in seven) as the mechanical stress to the graft increased. Included fracture on the tibia in 12 patients, humerus in one and femur in six. Treatments included casting in 11 patients, percutaneous pinning in one case, and adjustment of external fixator in seven patients. Bony union was finally achieved an average of 9.6 months after fracture. Correct alignment between the recipient bone and the external fixator is a prerequisite to preventing graft fracture. Vascularized fibula transfer is a valuable procedure for long-bone defects, and a skin island-monitoring flap is a simple, extremely useful, and reliable method for assessing the vascular status of vascularized fibula. Level IV. Retrospective study. Copyright © 2012. Published by Elsevier Masson SAS.
Uozumi, Y; Nagamune, K
2013-01-01
The purpose of this study is to propose an automatic segmentation about each bone (the femur, the tibia, the patellar, and fibular) of the knee in MDCT image. The proposed method was applied for six patients (Age 33 ± 13, four males/tew females). The proposed method segmented the knee joint into each bone by using anatomical structure for the knee joint. The experiments calculate matching rate of the manual and the proposed method for evaluating it. As a result, The matching rate of the femur, the tibia, the patellar, and fibula were 95.84 ± 0.57%, 94.12 ± 1.01%, 94.49 ± 0.83%, 86.37 ± 4.28%, respectively. This study concluded that the proposed method is enough to segment the knee bones.
Vascularised free fibular flap in bone resection and reconstruction.
Belt, P J; Dickinson, I C; Theile, D R B
2005-06-01
This paper compares allograft alone and in combination with vascularised free fibular flaps (FFF) to reconstruct long bone defects after tumour excision. We present 33 cases, 21 of these patients had reconstruction with an allograft alone as the initial procedure. Nine patients underwent reconstruction with FFF plus allograft plus iliac crest bone graft (ICG), two patients underwent reconstruction with a FFF and ICG and one patient underwent reconstruction with an allograft, a pedicled fibular flap and a FFF. The allograft was obtained from the Queensland Bone Bank and had been irradiated to 25 000Gy. In our experience (N=21) the complication rates with allograft alone were: delayed union 3, nonunion 7, fractured allograft 6, infection requiring resection of the allograft 3, other infections 2. The revision rate was 48% (10 cases of which five required a free fibular flap) and an average of 1.8 revision procedures were required. In the lower limb cases, the mean time to full weightbearing was 20 months and 40% were full weightbearing at 18 months. We felt that the high complication rate compared with other series may have been related to the irradiation of the graft. FFFs were used in 18 cases, 12 cases were primary reconstructions and six were revision reconstructions. The mean fibular length was 19.4 cm (range 10-29 cm). There were no flap losses and the FFF united at both ends of 11 of 12 primary reconstruction cases. One case had nonunion at one end, giving a union rate of 96% (23 of 24 junctions). When a FFF was used in combination with an allograft as a primary reconstruction, the allograft nonunion rate was 50% (five of 10 cases). The mean time to full weightbearing in the lower limb cases was 7.5 months and 100% were full weightbearing at 18 months. The FFF hastens time to full weightbearing but does not appear to affect the complication rates of allograft. The number of revision procedures required is reduced in the presence of a FFF and is the latter is a useful technique for the salvage of refractory cases.
Saridis, Alkis G; Megas, Panagiotis D; Georgiou, Christos S; Diamantakis, Georgios M; Tyllianakis, Minos E
2011-01-01
In the management of malignancies of the extremities, limb salvage procedures have recently taken on greater significance. For those patients under intense adjuvant chemotherapy and with massive bone loss, free vascularized fibular grafting is currently advocated as a reliable reconstructive option, maybe because of the controversial results of bone transport in similar situations. However, when there is a vascular abnormality of either the recipient or donor extremity, microsurgical procedures are not feasible, further limiting potential reconstructive alternatives. We present the case of a 13-year-old female patient with Ewing's sarcoma of the right tibia. Preoperative angiography showed that vascularity of the affected side depended totally on a single peroneal artery. The patient was treated initially with multiagent chemotherapy, followed by an excision of 23 cm. The defect was bridged by a gradual medial transportation of the ipsilateral fibula with the Ilizarov technique and strengthened by nonvascularized transfer of the contralateral fibula. Total external fixation time was 162 days. After the removal of the Ilizarov frame a walking cast was applied for another month. At 5 years postoperatively there was no recurrence of the malignancy. The patient had full weight-bearing ability on the affected limb, with preservation of the ankle and knee joints motion and without any limb length discrepancy or axial deformity. The functional outcome that was visible was graded excellent. Transverse distraction osteogenesis of the ipsilateral fibula performed well under chemotherapy, showing unproblematic callus formation. Supplemented with nonvascularized transfer of the contralateral fibula, provided a reconstructive option with biological affinity, sufficient biomechanical strength and durability, and with a decreased complication rate. This case report presents a viable option, especially in cases in which vascular abnormalities of either the donor or the recipient limb, combined with multiagent chemotherapy, restrict potential reconstructive alternatives. It also highlights why vascularized bone graft should not be regarded as a panacea for all situations in which a fibular graft is required. Level IV, case report.
Attal, R; Maestri, V; Doshi, H K; Onder, U; Smekal, V; Blauth, M; Schmoelz, W
2014-03-01
Using human cadaver specimens, we investigated the role of supplementary fibular plating in the treatment of distal tibial fractures using an intramedullary nail. Fibular plating is thought to improve stability in these situations, but has been reported to have increased soft-tissue complications and to impair union of the fracture. We proposed that multidirectional locking screws provide adequate stability, making additional fibular plating unnecessary. A distal tibiofibular osteotomy model performed on matched fresh-frozen lower limb specimens was stabilised with reamed nails using conventional biplanar distal locking (CDL) or multidirectional distal locking (MDL) options with and without fibular plating. Rotational stiffness was assessed under a constant axial force of 150 N and a superimposed torque of ± 5 Nm. Total movement, and neutral zone and fracture gap movement were analysed. In the CDL group, fibular plating improved stiffness at the tibial fracture site, albeit to a small degree (p = 0.013). In the MDL group additional fibular plating did not increase the stiffness. The MDL nail without fibular plating was significantly more stable than the CDL nail with an additional fibular plate (p = 0.008). These findings suggest that additional fibular plating does not improve stability if a multidirectional distal locking intramedullary nail is used, and is therefore unnecessary if not needed to aid reduction.
Pirela-Cruz, Miguel A; Hansen, Uel; Terreros, Daniel A; Rossum, Alfred; West, Priscilla
2009-03-01
This study explored the anatomical feasibility of using an interosseous nerve transfer (routed between the tibia and fibula) to restore motor function to the tibialis anterior (TA) muscle, following injury to the common peroneal nerve (resulting in a foot drop). The specific nerve branches evaluated as possible donor nerves included the nerves to the medial gastrocnemius, the lateral gastrocnemius, and the soleus muscles. All nerve transfers were accomplished using a direct interosseous route and a direct repair (one medial gastrocnemius transfer did require interpositional grafting). The distance from the repair site to the TA muscle was shortest for the transfer using the nerve branch to the soleus. Histologically, the nerve branch to the soleus was most similar to the branch to the TA for both axonal count and cross-sectional area. A two-incision surgical approach using a fibular window (mobilizing a fibular segment after double osteotomy) and interosseous routing of the transfer is proposed.
A comparison of surgical exposures for posterolateral osteochondral lesions of the talar dome.
Mayne, Alistair I W; Lawton, Robert; Reidy, Michael J; Harrold, Fraser; Chami, George
2018-04-01
Perpendicular access to the posterolateral talar dome for the management of osteochondral defects is difficult. We examined exposure available from each of four surgical approaches. Four surgical approaches were performed on 9 Thiel-embalmed cadavers: anterolateral approach with arthrotomy; anterolateral approach with anterior talo-fibular ligament (ATFL) release; anterolateral approach with antero-lateral tibial osteotomy; and anterolateral approach with lateral malleolus osteotomy. The furthest distance posteriorly allowing perpendicular access with a 2mm k-wire was measured. An anterolateral approach with arthrotomy provided a mean exposure of the anterior third of the lateral talar dome. A lateral malleolus osteotomy provided superior exposure (81.5% vs 58.8%) compared to an anterolateral tibial osteotomy. Only the anterior half of the lateral border of the talar dome could be accessed with an anterolateral approach without osteotomy. A fibular osteotomy provided best exposure to the posterolateral aspect of the talar dome. Copyright © 2016 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
Reconstructive procedures for segmental resection of bone in giant cell tumors around the knee.
Aggarwal, Aditya N; Jain, Anil K; Kumar, Sudhir; Dhammi, Ish K; Prashad, Bhagwat
2007-04-01
Segmental resection of bone in Giant Cell Tumor (GCT) around the knee, in indicated cases, leaves a gap which requires a complex reconstructive procedure. The present study analyzes various reconstructive procedures in terms of morbidity and various complications encountered. Thirteen cases (M-six and F-seven; lower end femur-six and upper end tibia -seven) of GCT around the knee, radiologically either Campanacci Grade II, Grade II with pathological fracture or Grade III were included. Mean age was 25.6 years (range 19-30 years). Resection arthrodesis with telescoping (shortening) over intramedullary nail (n=5), resection arthrodesis with an intercalary allograft threaded over a long intramedullary nail (n=3) and resection arthrodesis with intercalary fibular autograft and simultaneous limb lengthening (n=5) were the procedure performed. Shortening was the major problem following resection arthrodesis with telescoping (shortening) over intramedullary nail. Only two patients agreed for subsequent limb lengthening. The rest continued to walk with shortening. Infection was the major problem in all cases of resection arthrodesis with an intercalary allograft threaded over a long intramedullary nail and required multiple drainage procedures. Fusion was achieved after two years in two patients. In the third patient the allograft sequestrated. The patient underwent sequestrectomy, telescoping of fragments and ilizarov fixator application with subsequent limb lengthening. The patient was finally given an ischial weight relieving orthosis, 54 months after the index procedure. After resection arthrodesis with intercalary autograft and simultaneous lengthening the resultant gap (∼15cm) was partially bridged by intercalary nonvascularized dual fibular strut graft (6-7cm) and additional corticocancellous bone graft from ipsilateral patella. Simultaneous limb lengthening with a distal tibial corticotomy was performed on an ilizarov fixator. The complications were superficial infection (n=5), stress fracture of fibula (n=2). The stress fracture fibula required DCP fixation and bone grafting. The usual time taken for union and limb length equalization was approximately one year. Resection arthrodesis with intercalary dual fibular autograft and cortico-cancellous bone grafting with simultaneous limb lengthening achieved limb length equalization with relatively short morbidity.
Ohana, Nissim; Benharroch, Daniel; Sheinis, Dimitri
2018-04-13
A 26-year-old man, who was paraplegic for 6 years due to a motor vehicle accident, presented to the authors' clinic following his incapacity to withstand a sitting posture, the frequent sensation of "clicks" in his back, and a complaint of back pain while in his wheelchair. On imaging, his dorsal spine showed a complete arthrodesis of the primarily fused vertebrae. However, distal to this segment, a Charcot spinal arthropathy with subluxation of T12-L1 was evident. Repair of this complex, uncommon, late complication of his paraplegia by the frequently used fusion techniques was shown to be inappropriate. A novel and elaborate surgical procedure is presented by which a complete fusion of the affected spine was secured. A left retrodiaphragmatic approach was used. Complete corpectomy of both the T-12 and L-1 vertebrae to the preserved endplates was performed. Most of the patient's fibula was resected and shaped for engrafting. The segment of the fibula was introduced into a mesh cage, before its intramedullary implantation into the T-12 and L-1 vertebrae. This 2-step procedure combined the hybrid use of a fibular autograft and an expandable mesh cage, incorporated one into the other, in an innovative intramedullary position. This intervention allowed the patient to resume his former condition as an extremely physically active patient with paraplegia. Nine years later, an asymptomatic early-stage Charcot spine was found at L5-S1, but no treatment is planned at this point.
Huda, Najmul; Julfiqar; Pant, Ajay; Aslam, M
2015-01-01
Perioperative complications are well known during partial and total hip arthroplasty. One of the common categories of these complications is an intraoperative fractures of the proximal femur. Here we discuss a case of perforation of posteromedial cortex of the proximal femur, while doing a press fit modular bipolar hemiarthroplasty, in a young adult with secondary nonunion of the femoral neck fracture. The cause of this proximal femur perforation was residual fibular strut graft that, redirected the femoral stem into undesirable direction. This complication of residual fibular strut graft has not been disscussed much in the orthopedic literature previously. A press fit modular bipolar hiparthroplasty was performed in a young adult male with nonunion fracture neck of the femur secondary to initial fixation using 6.5mm cannulated hip screws and nonvascularized free fibular strut grafting. Failure to completely remove the fibular strut from the proximal femur lead to difficult negotiation of the femoral stem into the femoral canal and ultimately a perforation in the proximal femur at the level of the lesser trochanter. A revision procedure was done to completely remove the residual fibular graft, and then a fresh press fit modular bipolar hemiarthroplasty was done. Complete removal of fibular strut graft should be done, while performing hip arthroplasty in patients with failed fibular grafting for fracture neck of the femur.
New options for vascularized bone reconstruction in the upper extremity.
Houdek, Matthew T; Wagner, Eric R; Wyles, Cody C; Nanos, George P; Moran, Steven L
2015-02-01
Originally described in the 1970s, vascularized bone grafting has become a critical component in the treatment of bony defects and non-unions. Although well established in the lower extremity, recent years have seen many novel techniques described to treat a variety of challenging upper extremity pathologies. Here the authors review the use of different techniques of vascularized bone grafts for the upper extremity bone pathologies. The vascularized fibula remains the gold standard for the treatment of large bone defects of the humerus and forearm, while also playing a role in carpal reconstruction; however, two other important options for larger defects include the vascularized scapula graft and the Capanna technique. Smaller upper extremity bone defects and non-unions can be treated with the medial femoral condyle (MFC) free flap or a vascularized rib transfer. In carpal non-unions, both pedicled distal radius flaps and free MFC flaps are viable options. Finally, in skeletally immature patients, vascularized fibular head epiphyseal transfer can provide growth potential in addition to skeletal reconstruction.
Chronic ankle instability and common fibular nerve injury.
Benchortane, Michaël; Collado, Hervé; Coudreuse, Jean-Marie; Desnuelle, Claude; Viton, Jean-Michel; Delarque, Alain
2011-03-01
The lateral collateral ligaments of the ankle are often damaged in ankle inversion injuries. Ankle inversion may also cause injury to other structures located around the ankle or further away, such as the common fibular nerve. Few descriptions exist of common fibular nerve injury associated with ankle sprains and chronic ankle instability. We describe the case of a patient who sustained common fibular nerve injury during each of two ankle sprain recurrences involving the lateral collateral ligaments. Our objectives are to illustrate the links between common fibular nerve and lateral collateral ligament injuries and to emphasize the importance of the neurological evaluation in patients seen for ankle sprains or chronic ankle instability. Copyright © 2010 Société française de rhumatologie. Published by Elsevier SAS. All rights reserved.
Molecular development of fibular reduction in birds and its evolution from dinosaurs
Botelho, João Francisco; Smith‐Paredes, Daniel; Soto‐Acuña, Sergio; O'Connor, Jingmai; Palma, Verónica; Vargas, Alexander O.
2016-01-01
Birds have a distally reduced, splinter‐like fibula that is shorter than the tibia. In embryonic development, both skeletal elements start out with similar lengths. We examined molecular markers of cartilage differentiation in chicken embryos. We found that the distal end of the fibula expresses Indian hedgehog (IHH), undergoing terminal cartilage differentiation, and almost no Parathyroid‐related protein (PTHrP), which is required to develop a proliferative growth plate (epiphysis). Reduction of the distal fibula may be influenced earlier by its close contact with the nearby fibulare, which strongly expresses PTHrP. The epiphysis‐like fibulare however then separates from the fibula, which fails to maintain a distal growth plate, and fibular reduction ensues. Experimental downregulation of IHH signaling at a postmorphogenetic stage led to a tibia and fibula of equal length: The fibula is longer than in controls and fused to the fibulare, whereas the tibia is shorter and bent. We propose that the presence of a distal fibular epiphysis may constrain greater growth in the tibia. Accordingly, many Mesozoic birds show a fibula that has lost its distal epiphysis, but remains almost as long as the tibia, suggesting that loss of the fibulare preceded and allowed subsequent evolution of great fibulo–tibial disparity. PMID:26888088
Molecular development of fibular reduction in birds and its evolution from dinosaurs.
Botelho, João Francisco; Smith-Paredes, Daniel; Soto-Acuña, Sergio; O'Connor, Jingmai; Palma, Verónica; Vargas, Alexander O
2016-03-01
Birds have a distally reduced, splinter-like fibula that is shorter than the tibia. In embryonic development, both skeletal elements start out with similar lengths. We examined molecular markers of cartilage differentiation in chicken embryos. We found that the distal end of the fibula expresses Indian hedgehog (IHH), undergoing terminal cartilage differentiation, and almost no Parathyroid-related protein (PTHrP), which is required to develop a proliferative growth plate (epiphysis). Reduction of the distal fibula may be influenced earlier by its close contact with the nearby fibulare, which strongly expresses PTHrP. The epiphysis-like fibulare however then separates from the fibula, which fails to maintain a distal growth plate, and fibular reduction ensues. Experimental downregulation of IHH signaling at a postmorphogenetic stage led to a tibia and fibula of equal length: The fibula is longer than in controls and fused to the fibulare, whereas the tibia is shorter and bent. We propose that the presence of a distal fibular epiphysis may constrain greater growth in the tibia. Accordingly, many Mesozoic birds show a fibula that has lost its distal epiphysis, but remains almost as long as the tibia, suggesting that loss of the fibulare preceded and allowed subsequent evolution of great fibulo-tibial disparity. © 2016 The Author(s). Evolution published by Wiley Periodicals, Inc. on behalf of The Society for the Study of Evolution.
Uzun, Metin; Kara, Adnan; Adaş, Müjdat; Karslioğlu, Bülent; Bülbül, Murat; Beksaç, Burak
2014-01-01
Purpose. We evaluated whether intramedullary nail fixation for tibial diaphysis fractures with concomitant fibula fractures (except at the distal one-third level) managed conservatively with an associated fibula fracture resulted in ankle deformity and assessed the impact of the ankle deformity on lower extremity function. Methods. Sixty middle one-third tibial shaft fractures with associated fibular fractures, except the distal one-third level, were included in this study. All tibial shaft fractures were anatomically reduced and fixed with interlocking intramedullary nails. Fibular fractures were managed conservatively. Hindfoot alignment was assessed clinically. Tibia and fibular lengths were compared to contralateral measurements using radiographs. Functional results were evaluated using the Knee Injury and Osteoarthritis Outcome Score (KOOS) and the Foot and Ankle Disability Index Score (FADI). Results. Anatomic union, defined as equal length in operative and contralateral tibias, was achieved in 60 fractures (100%). Fibular shortening was identified in 42 fractures (68%). Mean fibular shortening was 1.2 cm (range, 0.5–2 cm). Clinical exams showed increased hindfoot valgus in 42 fractures (68%). The mean KOOS was 88.4, and the mean FADI score was 90. Conclusion. Fibular fractures in the middle or proximal one-third may need to be stabilized at the time of tibial intramedullary nail fixation to prevent development of hindfoot valgus due to fibular shortening. PMID:25544899
Evaluation of Fibular Fracture Type vs Location of Tibial Fixation of Pilon Fractures.
Busel, Gennadiy A; Watson, J Tracy; Israel, Heidi
2017-06-01
Comminuted fibular fractures can occur with pilon fractures as a result of valgus stress. Transverse fibular fractures can occur with varus deformation. No definitive guide for determining the proper location of tibial fixation exists. The purpose of this study was to identify optimal plate location for fixation of pilon fractures based on the orientation of the fibular fracture. One hundred two patients with 103 pilon fractures were identified who were definitively treated at our institution from 2004 to 2013. Pilon fractures were classified using the AO/OTA classification and included 43-A through 43-C fractures. Inclusion criteria were age of at least 18 years, associated fibular fracture, and definitive tibial plating. Patients were grouped based on the fibular component fracture type (comminuted vs transverse), and the location of plate fixation (medial vs lateral) was noted. Radiographic outcomes were assessed for mechanical failures. Forty fractures were a result of varus force as evidenced by transverse fracture of the fibula and 63 were due to valgus force with a comminuted fibula. For the transverse fibula group, 14.3% mechanical complications were noted for medially placed plate vs 80% for lateral plating ( P = .006). For the comminuted fibular group, 36.4% of medially placed plates demonstrated mechanical complications vs 16.7% for laterally based plates ( P = .156). Time to weight bearing as tolerated was also noted to be significant between groups plated medially and laterally for the comminuted group ( P = .013). Correctly assessing the fibular component for pilon fractures provides valuable information regarding deforming forces. To limit mechanical complications, tibial plates should be applied in such a way as to resist the original deforming forces. Level of Evidence Level III, comparative study.
Mishima, Kenichi; Kitoh, Hiroshi; Iwata, Koji; Matsushita, Masaki; Nishida, Yoshihiro; Hattori, Tadashi; Ishiguro, Naoki
2016-05-01
Fibular hemimelia is a rare but the most common congenital long bone deficiency, encompassing a broad range of anomalies from isolated fibular hypoplasia up to substantial femoral and tibial shortening with ankle deformity and foot deficiency. Most cases of fibular hemimelia manifest clinically significant leg length discrepancy (LLD) with time that requires adequate correction by bone lengthening for stable walking. Bone lengthening procedures, especially those for pathological bones, are sometimes associated with severe complications, such as delayed consolidation, fractures, and deformities of the lengthened bones, leading to prolonged healing time and residual LLD at skeletal maturity. The purpose of this study was to review our clinical results of lower limb lengthening for fibular hemimelia.This study included 8 Japanese patients who diagnosed with fibular hemimelia from physical and radiological findings characteristic of fibular hemimelia and underwent single or staged femoral and/or tibial lengthening during growth or after skeletal maturity. LLD, state of the lengthened callus, and bone alignment were evaluated with full-length radiographs of the lower limb. Previous interventions, associated congenital anomalies, regenerate fractures were recorded with reference to medical charts and confirmed on appropriate radiographs. Successful lengthening was defined as the healing index <50 days/cm without regenerate fractures.A significant difference was observed in age at surgery between successful and unsuccessful lengthening. The incidence of regenerate fractures was significantly correlated with callus maturity before frame removal. LLD was corrected within 11 mm, whereas mechanical axis deviated laterally.Particular attention should be paid to the status of callus maturation and the mechanical axis deviation during the treatment period in fibular hemimelia.
[Tibia reconstruction using cross-leg pedicled fibular flaps: report of two cases].
Molski, M
2000-01-01
The paper presents the results of treatment of two children with cross-leg pedicle fibular flaps. A boy (10 years old) was operated because of an extensive defect of the proximal tibial shaft (15 cm) and soft tissue deficit due to osteosarcoma. He had been previously operated several times: tumor resection with chemiotherapy, bone reconstruction using allografts and two other procedures because of inflammatory complications. The second case was a 9-year old girl who underwent an extensive excision of congenital pseudoarthrosis of the tibia due to neurofibroma and reconstruction of the further fragment of the tibia. Vascularized fibula was nailed deep into the tibial shaft, beyond the previously implanted metal elements. This allowed to maintain a correct axis of the limb, a firm stabilization of the transplant and probably evoked a quick periosteal reaction of the tibia. Plaster of Paris was used to immobilize the limb. Postoperative course showed no complications. The flap pedicle was cut off after 3-4 weeks. Progressive bone healing followed by bony hypertrophy was observed after 8 weeks. The children were able to fully load the operated extremities and ambulate without crutches (the boys 12 months post-surgery and the girl 6 months post-surgery).
Louie, Brian E.; McKee, Michael D.; Richards, Robin R.; Mahoney, James L.; Waddell, James P.; Beaton, Dorcas E.; Schemitsch, Emil H.; Yoo, Daniel J.
1999-01-01
Objective To evaluate the limb-specific outcome and general health status of patients with osteonecrosis of the femoral head treated with vascularized fibular grafting. Design A retrospective review. Setting A single tertiary care centre. Patients Fifty-five consecutive patients with osteonecrosis of the femoral head who underwent fibular grafting (8 bilaterally). Intervention Vascularized fibular grafting. Outcome measures Limb-specific scores (Harris Hip Score, St. Michael’s Hospital Hip Score), general health status (Nottingham Health Profile, SF-36 health status survey) and radiographic outcome measures (Steinberg stage). Results Patients were young (mean age 34 years, range from 18 to 52 years) and 80% had advanced osteonecrosis (Steinberg stages IV and V). Fifty-nine hips were followed up for an average of 50 months (range from 24 to 117 months) after vascularized fibular grafting. Sixteen hips (27%) were converted to total hip arthroplasty (THA). To date, 73% of hips treated with vascularized fibular grafting have required no further surgery. Preoperative and postoperative Harris Hip Scores were 57.3 and 83.6 respectively (p < 0.001). As measured by patient-oriented health status questionnaires (SF-36, Nottingham Health Profile) and compared with population controls, patients had normal mental health scores and only slight decreases in physical component scores. Conclusions Free vascularized fibular grafting for osteonecrosis of the femoral head provides satisfactory pain relief, functional improvement and general health status and halts the progression of symptomatic disease. PMID:10459327
Tibiotalar nonunion corrected by hindfoot arthrodesis.
Giza, Eric; Sarcon, Annahita K; Kreulen, Christopher
2010-04-01
A 65-year-old man without significant comorbidities was referred to the senior author (EG) 9 months after an ankle arthrodesis procedure with complaints of pain, swelling, and progressive hindfoot valgus. The patient had elected to have the index surgery because of severe ankle arthritis due to longstanding lateral ankle instability. Physical examination revealed a well-healed anterior, midline ankle incision with normal pulses and sensation. Painful, limited ankle and subtalar range of motion was noted along with 20 degrees of hindfoot valgus and subfibular impingement. Radiographs of the ankle revealed an attempted ankle fusion using a knee arthroplasty trabecular metal augment placed vertically at the tibiotalar joint. There were no screws or other hardware present to provide compression and stability of the fusion. A computed tomography scan showed a tibiotalar nonunion, erosion of the talar body, and severe tibiotalar and subtalar arthritis. Inflammatory markers were within normal range. Based on the findings of a failed fusion and progressive painful hindfoot deformity, it was determined that the patient would benefit from removal of the hardware and revision fusion surgery. Tibiotalocalcaneal (TTC) hindfoot fusion was planned because of the patient's talar collapse and tibiotalar/ subtalar arthritis. The TTC procedure was performed with a retrograde intramedullary nail, femoral head allograft, and morselized fibular autograft enriched with platelet-rich plasma. The femoral head was used as a structural allograft to fill the large bone defect, prevent limb shortening, and assist in correction of the hindfoot deformity. Intraoperative findings revealed severe metallic synovitis of the ankle and subtalar joints, metal debris at the site of the trabecular implant, and segmental defects of the distal tibia and talus. Weight bearing was permitted after 16 weeks when evidence of successful ankle fusion was confirmed radiographically. At 24 months, the patient was pain free and ambulating without difficulty.
Lee, Dong Yeon; Kim, Joong Il; Song, Mi Hyun; Choi, Eun Seok; Park, Moon Seok; Yoo, Won Joon; Chung, Chin Youb; Choi, In Ho; Cho, Tae-Joon
2014-01-01
Hereditary multiple exostoses (HME) patients frequently present with ankle valgus deformity and marked fibular shortening. Loss of the lateral buttress may cause translational talus instability (TTI) that manifests as ankle pain after physical exercise, medial clear space widening on plain radiographs, and gross translational movement of the talus within the mortise. Among 123 HME patients examined and/or surgically treated, 10 patients (14 ankles) with symptomatic TTI underwent fibular lengthening with osteochondroma excision. Twelve ankles of 9 patients were followed for >1 year after surgery. Total fibular length gain averaged 15.3 mm and distal migration of the distal fibular fragment averaged 5.5 mm. The mean medial clear space decreased from preoperative 6.7 mm to postlengthening 3.5 mm. Gross instability of the talus within the ankle mortise disappeared in all cases. AOFAS ankle-hindfoot score improved from preoperative 80.3 to 97.3 at the latest follow-up. The current study showed the fibular lengthening improved lateral ankle stability by providing lateral buttress on the talus and providing favorable short-term result by ameliorating exercise-induced ankle pain in TTI of HME. The authors carefully conclude that TTI is a rare but potentially disabling condition in HME patients, requiring special attention during follow-up of HME patients. Level IV.
White, T O; Bugler, K E; Appleton, P; Will, E; McQueen, M M; Court-Brown, C M
2016-09-01
The fundamental concept of open reduction and internal fixation (ORIF) of ankle fractures has not changed appreciably since the 1960s and, whilst widely used, is associated with complications including wound dehiscence and infection, prominent hardware and failure. Closed reduction and intramedullary fixation (CRIF) using a fibular nail, wires or screws is biomechanically stronger, requires minimal incisions, and has low-profile hardware. We hypothesised that fibular nailing in the elderly would have similar functional outcomes to standard fixation, with a reduced rate of wound and hardware problems. A total of 100 patients (25 men, 75 women) over the age of 65 years with unstable ankle fractures were randomised to undergo standard ORIF or fibular nailing (11 men and 39 women in the ORIF group, 14 men and 36 women in the fibular nail group). The mean age was 74 years (65 to 93) and all patients had at least one medical comorbidity. Complications, patient related outcome measures and cost-effectiveness were assessed over 12 months. Significantly fewer wound infections occurred in the fibular nail group (p = 0.002). At one year, there was no evidence of difference in mean functional scores (Olerud and Molander Scores 63; 30 to 85, versus 61; 10 to 35, p = 0.61) or scar satisfaction. The overall cost of treatment in the fibular nail group was £91 less than in the ORIF group despite the higher initial cost of the implant. We conclude that the fibular nail allows accurate reduction and secure fixation of ankle fractures, with a significantly lower rate of soft-tissue complications, and is more cost-effective than ORIF. Cite this article: Bone Joint J 2016;98-B:1248-52. ©2016 The British Editorial Society of Bone & Joint Surgery.
Burkhart, Timothy A; Asa, Benjamin; Payne, Michael W C; Johnson, Marjorie; Dunning, Cynthia E; Wilson, Timothy D
2015-02-01
A result of below-knee amputations (BKAs) is abnormal motion that occurs about the proximal tibiofibular joint (PTFJ). While it is known that joint morphology may play a role in joint kinematics, this is not well understood with respect to the PTFJ. Therefore, the purposes of this study were: (i) to characterize the anatomy of the PTFJ and statistically analyze the relationships within the joint; and (ii) to determine the relationships between the PTFJ characteristics and the degree of movement of the fibula in BKAs. The PTFJ was characterized in 40 embalmed specimens disarticulated at the knee, and amputated through the mid-tibia and fibula. Four metrics were measured: inclination angle (angle at which the fibula articulates with the tibia); tibial and fibular articular surface areas; articular surface concavity and shape. The specimens were mechanically tested by applying a load through the biceps femoris tendon, and the degree of motion about the tibiofibular joint was measured. Regression analyses were performed to determine the relationships between the different PTFJ characteristics and the magnitude of fibular abduction. Finally, Pearson correlation analyses were performed on inclination angle and surface area vs. fibular kinematics. The inclination angle measured on the fibula was significantly greater than that measured on the tibia. This difference may be attributed to differences in concavity of the tibial and fibular surfaces. Surface area measured on the tibia and fibula was not statistically different. The inclination angle was not statistically correlated to surface area. However, when correlating fibular kinematics in BKAs, inclination angle was positively correlated to the degree of fibular abduction, whereas surface area was negatively correlated. The characteristics of the PTFJ dictate the amount of fibular movement, specifically, fibular abduction in BKAs. Predicting BKA complications based on PTFJ characteristics can lead to recommendations in treatment. © 2014 Anatomical Society.
Kashayi-Chowdojirao, Sreekanth; Vallurupalli, Aashish; Chilakamarri, Vijay Krishna; Patnala, Chandrasekhar; Chodavarapu, Lalith Mohan; Kancherla, Nageswara Rao; Khazi Syed, Asif Hussain
2017-11-01
Non-union humeral shaft fractures are seen frequently in clinical practice at about 2-10% in conservative management and 30% in surgically operated patients. Osteosynthesis using dynamic compression plate (DCP), intramedullary nailing, locking compression plate (LCP), Ilizarov technique along with bone grafting have been reported previously. In cases of prior failed plate-screw osteosynthesis the resultant osteopenia, cortical defect, bone loss, scalloping around screws and metallosis, make the management of non-union more complicated. Fibular graft as an intramedullary strut is useful in these conditions by increasing screw purchase, union and mechanical stability. This study is a retrospective and prospective follow up of revision plating along with autologous non-vascularised intramedullary fibular strut graft (ANVFG) for humeral non-unions following failed plate osteosynthesis. Seventy eight cases of nonunion humeral shaft fractures were managed in our institute between 2008 and 2015. Of these, 57 cases were failed plate osteosynthesis, in which 15 cases were infected and 42 cases were noninfected. Out of the 78 cases, bone grafting was done in 55 cases. Fibular strut graft was used in 22 patients, of which 4 cases were of primary nonunion with osteoporotic bone. Applying the exclusion criteria of infection and inclusion criteria of failed plate osteosynthesis managed with revision plating using either LCP or DCP and ANVFG, 17 cases were studied. The mean age of the patients was 40.11 yrs (range: 26-57 yrs). The mean duration of non-union was 4.43 yrs (range: 0.5-14 yrs). The mean follow-up period was 33.41 months (range: 12-94 months). The average length of fibula was 10.7 cm (range: 6-15 cm). Main outcome measurements included bony union by radiographic assessment and pre- and postoperative functional evaluation using the DASH (Disabilities of the Arm, Shoulder and Hand) score. Results: Sixteen out of 17 fractures united following revision plating and fibular strut grafting. Average time taken for union was 3.5 months (range: 3-5 months). Complications included one each of implant failure with bending, transient radial nerve palsy and transient ulnar nerve palsy. No case had infection, graft site morbidity or peroneal nerve palsy. Functional assessment by DASH score improved from 59.14 (range: 43.6-73.21) preoperatively to 23.39 (range: 8.03-34.2) postoperatively (p = 0.0003). Conclusion: The results of our study indicate that revision plating along with ANVFG is a reliable option in humeral diaphyseal non-unions with failed plate-screw osteosynthesis providing adequate screw purchase, mechanical stability and high chances of union with good functional outcome.
NASA Astrophysics Data System (ADS)
Wang, Xuejuan; Wu, Shuhang; Liu, Yunpeng
2018-04-01
This paper presents a new method for wood defect detection. It can solve the over-segmentation problem existing in local threshold segmentation methods. This method effectively takes advantages of visual saliency and local threshold segmentation. Firstly, defect areas are coarsely located by using spectral residual method to calculate global visual saliency of them. Then, the threshold segmentation of maximum inter-class variance method is adopted for positioning and segmenting the wood surface defects precisely around the coarse located areas. Lastly, we use mathematical morphology to process the binary images after segmentation, which reduces the noise and small false objects. Experiments on test images of insect hole, dead knot and sound knot show that the method we proposed obtains ideal segmentation results and is superior to the existing segmentation methods based on edge detection, OSTU and threshold segmentation.
Tarsitano, A; Ciocca, L; Cipriani, R; Scotti, R; Marchetti, C
2015-06-01
Free fibula flap is routinely used for mandibular reconstructions. For contouring the flap, multiple osteotomies should be shaped to reproduce the native mandibular contour. The bone segments should be fixed using a reconstructive plate. This plate is usually manually bent by the surgeon during surgery. This method is efficient, but during reconstruction it is complicated to reproduce the complex 3D conformation of the mandible and recreate a normal morphology with a mandibular profile as similar as possible to the original; any aberration in its structural alignment may lead to aesthetic and function alterations due to malocclusion or temporomandibular disorders. In order to achieve better morphological and functional outcomes, we have performed a customised flap harvest using cutting guides. This study demonstrates how we have performed customised mandibular reconstruction using CAD-CAM fibular cutting guides in 20 patients undergoing oncological segmental resection.
Markolf, Keith L; Jackson, Steven; McAllister, David R
2012-09-01
Syndesmosis (high ankle) sprains produce disruption of the distal tibiofibular ligaments. Forces on the distal fibula that produce these injuries are unknown. Twenty-seven fresh-frozen lower extremities were used for this study. A load cell recorded forces acting on the distal fibula from forced ankle dorsiflexion and applied external foot torque; medial-lateral and anterior-posterior displacements of the distal fibula were recorded. Fibular forces and axial displacements were also recorded with applied axial force. During forced ankle dorsiflexion and external foot torque tests, the distal fibula always displaced posteriorly with respect to the tibia with no measurable medial-lateral displacement. With 10 Nm dorsiflexion moment, cutting the tibiofibular ligaments approximately doubled fibular force and displacement values. Cutting the tibiofibular ligaments significantly increased fibular displacement from applied external foot torque. Fibular forces and axial displacements from applied axial weight-bearing force were highest with the foot dorsiflexed. The highest mean fibular force in the study (271.9 N) occurred with 10 Nm external foot torque applied to a dorsiflexed foot under 1000 N axial force. Two important modes of loading that could produce high ankle sprains were identified: forced ankle dorsiflexion and external foot torque applied to a dorsiflexed ankle loaded with axial force. The distal tibiofibular ligaments restrained fibular displacement during these tests. Residual mortise widening observed at surgery may be the result of tibiofibular ligament injuries caused by posterior displacement of the fibula. Therefore, a syndesmosis screw used to fix the fibula would be subjected to posterior bending forces from these loading modes. Ankle bracing to prevent extreme ankle dorsiflexion during rehabilitation may be advisable to prevent excessive fibular motions that could affect syndesmosis healing.
Havet, Eric; Gabrion, Antoine; Leiber-Wackenheim, Frederic; Vernois, Joël; Olory, Bruno; Mertl, Patrice
2007-06-01
Restoring the joint line level is one of the surgical challenges during revision of total knee arthroplasty. The position of the tibial surface is commonly estimated by its distance to the apex of fibular head, but no study evaluating this distance accurately has been published yet. The purpose of this work was to study the distance between the knee joint line and the apex of the fibular head and the proximal tibia, particularly the tibial tuberosity. Variability with clinical data and relations with other local measurements have been evaluated on knee radiographs (an antero-posterior view, a medio-lateral view and an anteroposterior full length view) of 100 subjects (125 knees). Results showed no correlation between the joint line-fibular head apex distance and any clinical data of the patients, or any other performed measurements. Relations between tibial measurements and the sexe or the height of the subjects were noted. Besides, the review of the 25 bilateral cases did not show statistically significant side difference but the descriptive analysis showed too large discrepancies for the joint line-fibular head apex distance to be used as a landmark. We conclude that the fibular head apex cannot be used as a morphologic landmark to determine the knee joint line position. Its interest in clinical and surgical practice must be discussed.
Tseng, Wan-Ling; Chang, Tzu-Yen; Hung, Kuo-Shu; Chen, Szu-Han; Hsiao, Jenn-Ren; Lee, Yao-Chou
2017-01-01
The titanium mesh or bone graft is usually used for orbital support after a globe-sparing total maxillectomy. However, its use can invite complications, such as infection, exposure, and absorption, especially for patients who require adjuvant radiotherapy. Here, the authors present a patient who received total maxillary reconstruction with an osteocutaneous fibular flap. A 53-year-old man with the diagnosis of maxillary osteosarcoma received a globe-sparing total maxillectomy. A bi-paddle double-barrel osteocutaneous fibular flap was used for orbital support, alveolar ridge recreation, and oro-sino-nasal separation. The short pedicle length inherent in the double-barrel design of the fibular flap was overcome by creating an arteriovenous saphenous loop. The postoperative recovery was uneventful. During the 9 months follow-up, the patient was tumor-free and satisfied with his appearance, speech, and intake functions. Reconstruction with a bi-paddle double-barrel osteocutaneous fibular flap after a globe-sparing total maxillectomy can achieve satisfactory aesthetic and functional results.
Leiggener, C; Messo, E; Thor, A; Zeilhofer, H-F; Hirsch, J-M
2009-02-01
The free fibular flap is the standard procedure for reconstructing mandibular defects. The graft has to be contoured to fit the defect so preoperative planning is required. The systems used previously do not allow transfer of the surgical plan to the operation room in an optimal way. The authors present a method to bring the virtual plan to real time surgery using a rapid prototyping guide. Planning was conducted using the Surgicase CMF software simulating surgery on a workstation. The osteotomies were translated into a rapid prototyping guide, sterilised and applied during surgery on the fibula allowing for the osteotomies and osteosynthesis to be performed with intact circulation. During reconstruction the authors were able to choose the best site for the osteotomies regarding circulation and as a result increased the precision and speed of treatment.
Tang, Xiaodong; Guo, Wei; Yang, Rongli; Yan, Taiqiang; Tang, Shun; Li, Dasen
2017-12-01
Pelvic reconstruction after periacetabular tumor resection is technically difficult and characterized by a high complication rate. Although endoprosthetic replacement can result in immediate postoperative functional recovery, biologic reconstructions with autograft may provide an enhanced prognosis in patients with long-term survival; however, little has been published regarding this approach. We therefore wished to evaluate whether whole-bulk femoral head autograft that is not contaminated by tumor can be used to reconstruct segmental bone defects after intraarticular resection of periacetabular tumors. In a pilot study, we evaluated (1) local tumor control, (2) complications, and (3) postoperative function as measured by the Musculoskeletal Tumor Society score. Between 2009 and 2015, we treated 13 patients with periacetabular malignant or aggressive benign tumors with en bloc resection, bulk femoral head autograft, and cemented THA (with or without a titanium acetabular reconstruction cup), and all were included for analysis here. During that time, the general indications for this approach were (1) patients anticipated to have a good oncologic prognosis and adequate surgical margins to allow this approach, (2) patients whose pelvic bone defects did not exceed two types (Types I + II or Types II + III as defined by Enneking and Dunham), and (3) patients whose medical insurance would not cover what otherwise might have been a pelvic tumor prosthesis. During this period, another 91 patients were treated with pelvic prosthetic replacement, which was our preferred approach. Median followup in this study was 36 months (range, 24-99 months among surviving patients; one patient died 8 months after surgery); no patients were lost to followup. Bone defects were Types II + III in five patients, and Types I + II in eight. After intraarticular resection, ipsilateral femoral head autograft combined with THA was used to reconstruct the segmental bone defect of the acetabulum. In patients with Types I + II resections, the connection between the sacrum and the acetabulum was reestablished with a fibular autograft or a titanium cage filled with dried bone-allograft particles which was enhanced by using a pedicle screw and rod system. Functional evaluation was done in 11 patients who remained alive and maintained the femoral head autograft at final followup; one other patient received secondary resection involving removal of the femoral head autograft and internal fixation, and was excluded from functional evaluation. Endpoints were assessed by chart review. Two patients experienced local tumor recurrence. Finally, eight patients did not show signs of the disease, one patient died of disease for local and distant tumor relapse, and four patients survived, but still had the disease. Three of these four patients had distant metastases without local recurrence and one had local control after secondary resection but still experienced system relapse. We observed the following complications: hematoma (one patient; treated surgically with hematoma clearance), delayed wound healing (one patient; treated by débridement), deep vein thrombosis (one patient), and hip dislocation (one patient; treated with open reduction). The median 1993 Musculoskeletal Tumor Society score was 83% (25 of 30 points; range, 19-29 points), and all patients were community ambulators; one used a cane, three used a walker, and nine did not use any assistive devices. In this small series at short-term followup, we found that reconstruction of segmental bone defects after intraarticular resection of periacetabular tumors with femoral head autograft does not appear to impede local tumor control; complications were in the range of what might be expected in a series of large pelvic reconstructions, and postoperative function was generally good. Level IV, therapeutic study.
The Nature of Foot Ray Deficiency in Congenital Fibular Deficiency.
Reyes, Bryan A; Birch, John G; Hootnick, David R; Cherkashin, Alex M; Samchukov, Mikhail L
Absent lateral osseous structures in congenital fibular deficiency, including the distal femur and fibula, have led some authors to refer to the nature of foot ray deficiency as "lateral" as well. Others have suggested that the ray deficiency is in the central portion of the midfoot and forefoot.We sought to determine whether cuboid preservation and/or cuneiform deficiency in the feet of patients with congenital fibular deficiency implied that the ray deficiency is central rather than lateral in patients with congenital fibular deficiency. We identified all patients with a clinical morphologic diagnosis of congenital fibular deficiency at our institution over a 15-year period. We reviewed the records and radiographs of patients who had radiographs of the feet to allow determination of the number of metatarsals, the presence or absence of a cuboid or calcaneocuboid fusion, the number of cuneiforms present (if possible), and any other osseous abnormalities of the foot. We excluded patients with 5-rayed feet, those who had not had radiographs of the feet, or whose radiographs were not adequate to allow accurate assessment of these radiographic features. We defined the characteristic "lateral (fifth) ray present" if there was a well-developed cuboid or calcaneocuboid coalition with which the lateral-most preserved metatarsal articulated. Twenty-six patients with 28 affected feet met radiographic criteria for inclusion in the study. All affected feet had a well-developed cuboid or calcaneocuboid coalition. The lateral-most ray of 25 patients with 26 affected feet articulated with the cuboid or calcaneocuboid coalition. One patient with bilateral fibular deficiency had bilateral partially deficient cuboids, and the lateral-most metatarsal articulated with the medial remnant of the deformed cuboids. Twenty-one of 28 feet with visible cuneiforms had 2 or 1 cuneiform. Although the embryology and pathogenesis of congenital fibular deficiency remain unknown, based on the radiographic features of the feet in this study, congenital fibular deficiency should not be viewed as a global "lateral lower-limb deficiency" nor the foot ray deficiency as "lateral." Level IV-prognostic study.
Defect Detection of Steel Surfaces with Global Adaptive Percentile Thresholding of Gradient Image
NASA Astrophysics Data System (ADS)
Neogi, Nirbhar; Mohanta, Dusmanta K.; Dutta, Pranab K.
2017-12-01
Steel strips are used extensively for white goods, auto bodies and other purposes where surface defects are not acceptable. On-line surface inspection systems can effectively detect and classify defects and help in taking corrective actions. For detection of defects use of gradients is very popular in highlighting and subsequently segmenting areas of interest in a surface inspection system. Most of the time, segmentation by a fixed value threshold leads to unsatisfactory results. As defects can be both very small and large in size, segmentation of a gradient image based on percentile thresholding can lead to inadequate or excessive segmentation of defective regions. A global adaptive percentile thresholding of gradient image has been formulated for blister defect and water-deposit (a pseudo defect) in steel strips. The developed method adaptively changes the percentile value used for thresholding depending on the number of pixels above some specific values of gray level of the gradient image. The method is able to segment defective regions selectively preserving the characteristics of defects irrespective of the size of the defects. The developed method performs better than Otsu method of thresholding and an adaptive thresholding method based on local properties.
2015-10-01
IFM ) through the separated bone cortices (fracture gap). In research funded by a CDMRP Idea Development Award, we used a rat segmental defect...491, 2011. [3] V. Glatt, M . Miller, a Ivkovic, F. Liu, N. Parry, D. Griffin, M . Vrahas, and C. Evans, “Improved healing of large segmental defects...2012. [4] M . Mehta, S . Checa, J. Lienau, D. Hutmacher, and G. N. Duda, “In vivo tracking of segmental bone defect healing reveals that callus
Diagnostic Cutoff Value for Ultrasonography of the Common Fibular Neuropathy at the Fibular Head
2016-01-01
Objective To establish the diagnostic cutoff value of ultrasonographic measurement for common fibular neuropathy (CFN) at the fibular head (FH). Methods Twenty patients with electrodiagnostically diagnosed CFN at the FH and 30 healthy controls were included in the study. The cross-sectional area (CSA) of sciatic nerve at mid-thigh level, common fibular nerve at popliteal fossa (PF), and common fibular (CF) nerve at FH were measured. Additionally, the difference of CF nerve CSA at the FH between symptomatic side and asymptomatic side (ΔSx–Asx), the ratio of CF nerve CSA at FH to at PF (FH/PF), and the ratio of CF nerve CSA at the FH symptomatic side to asymptomatic side (Ratio Sx–Asx) were calculated. Results CSA at the FH, FH/PF, ΔSx–Asx, and Ratio Sx–Asx showed significant differences between the patient and control groups. The cutoff value for diagnosing CFN at the FH was 11.7 mm2 for the CSA at the FH (sensitivity 85.0%, specificity 90.0%), 1.70 mm2 for the ΔSx–Asx (sensitivity 83.3%, specificity 97.0%), 1.11 for the FH/PF (sensitivity 47.1%, specificity 93.3%), and 1.24 for the Ratio Sx–Asx (sensitivity 72.2%, specificity 96.7%). Conclusion The ultrasonographic measurement and cutoff value could be a valuable reference in diagnosing CFN at the FH and improving diagnostic reliability and efficacy. PMID:28119836
Methods of reconstruction for bone defect after tumor excision: a review of alternatives.
Nishida, Jun; Shimamura, Tadashi
2008-08-01
Bone defect is a common problem encountered in the treatment of musculoskeletal tumor surgery. Allograft is a commonly used technique to reconstruct a large osseous defect following tumor excision in the United States and some European countries, and relatively good results have been reported because of its biologic nature. However, with the use of an allograft, there are concerns of transmission of infectious diseases, immunological reactions, and social or religious refusal in some regions in the world. Under these circumstances, vascularized autogenous fibular or iliac bone grafts are commonly used techniques and bone lengthening techniques using external fixation have been reported recently. These procedures utilize viable bone. In addition to these procedures, some biological reconstructive techniques utilizing nonviable bone have been performed as surgical alternatives for allografts using treated recycling bone including irradiated or pasteurized resected bone graft and reconstruction using an autograft containing tumor treated by liquid nitrogen. Although each technique has its proper advantages and disadvantages, the clinical results are similar to the allograft, and numerous techniques are now available as reasonable alternatives for allografts.
Tibial and fibular nerves evaluation using intraoperative electromyography in rats.
Nepomuceno, André Coelho; Politani, Elisa Landucci; Silva, Eduardo Guandelini da; Salomone, Raquel; Longo, Marco Vinicius Losso; Salles, Alessandra Grassi; Faria, José Carlos Marques de; Gemperli, Rolf
2016-08-01
To evaluate a new model of intraoperative electromyographic (EMG) assessment of the tibial and fibular nerves, and its respectives motor units in rats. Eight Wistar rats underwent intraoperative EMG on both hind limbs at two different moments: week 0 and week 12. Supramaximal electrical stimulation applied on sciatic nerve, and compound muscle action potential recorded on the gastrocnemius muscle (GM) and the extensor digitorum longus muscle (EDLM) through electrodes at specifics points. Motor function assessment was performaced through Walking Track Test. Exposing the muscles and nerves for examination did not alter tibial (p=0.918) or fibular (p=0.877) function between the evaluation moments. Electromyography of the GM, innervated by the tibial nerve, revealed similar amplitude (p=0.069) and latency (p=0.256) at week 0 and at 12 weeks, creating a standard of normality. Meanwhile, electromyography of the EDLM, innervated by the fibular nerve, showed significant differences between the amplitudes (p=0.003) and latencies (p=0.021) at the two different moments of observation. Intraoperative electromyography determined and quantified gastrocnemius muscle motor unit integrity, innervated by tibial nerve. Although this study was not useful to, objectively, assess extensor digitorum longus muscle motor unit, innervated by fibular nerve.
Wang, Xiaohu; Wei, Lei; Lv, Zhi; Zhao, Bin; Duan, Zhiqing; Wu, Wenjin; Zhang, Bin; Wei, Xiaochun
2017-02-01
Objective To explore the effects of proximal fibular osteotomy as a new surgery for pain relief and improvement of medial joint space and function in patients with knee osteoarthritis. Methods From January 2015 to May 2015, 47 patients who underwent proximal fibular osteotomy for medial compartment osteoarthritis were retrospectively followed up. Preoperative and postoperative weight-bearing and whole lower extremity radiographs were obtained to analyse the alignment of the lower extremity and ratio of the knee joint space (medial/lateral compartment). Knee pain was assessed using a visual analogue scale, and knee ambulation activities were evaluated using the American Knee Society score preoperatively and postoperatively. Results Medial pain relief was observed in almost all patients after proximal fibular osteotomy. Most patients exhibited improved walking postoperatively. Weight-bearing lower extremity radiographs showed an average increase in the postoperative medial knee joint space. Additionally, obvious correction of alignment was observed in the whole lower extremity radiographs in 8 of 47 patients. Conclusions The present study demonstrates that proximal fibular osteotomy effectively relieves pain and improves joint function in patients with medial compartment osteoarthritis at a mean of 13.38 months postoperatively.
Role of the fibula in the stability of diaphyseal tibial fractures fixed by intramedullary nailing.
Galbraith, John G; Daly, Charles J; Harty, James A; Dailey, Hannah L
2016-10-01
For tibial fractures, the decision to fix a concomitant fibular fracture is undertaken on a case-by-case basis. To aid in this clinical decision-making process, we investigated whether loss of integrity of the fibula significantly destabilises midshaft tibial fractures, whether fixation of the fibula restores stability to the tibia, and whether removal of the fibula and interosseous membrane for expediency in biomechanical testing significantly influences tibial interfragmentary mechanics. Tibia/fibula pairs were harvested from six cadaveric donors with the interosseous membrane intact. A tibial osteotomy fracture was fixed by reamed intramedullary (IM) nailing. Axial, torsion, bending, and shear tests were completed for four models of fibular involvement: intact fibula, osteotomy fracture, fibular plating, and resected fibula and interosseous membrane. Overall construct stiffness decreased slightly with fibular osteotomy compared to intact bone, but this change was not statistically significant. Under low loads, the influence of the fibula on construct stability was only statistically significant in torsion (large effect size). Fibular plating stiffened the construct slightly, but this change was not statistically significant compared to the fibular osteotomy case. Complete resection of the fibula and interosseous membrane significantly decreased construct torsional stiffness only (large effect size). These results suggest that fixation of the fibula may not contribute significantly to the stability of diaphyseal tibial fractures and should not be undertaken unless otherwise clinically indicated. For testing purposes, load-sharing through the interosseous membrane contributes significantly to overall construct mechanics, especially in torsion, and we recommend preservation of these structures when possible. Copyright © 2016 Elsevier Ltd. All rights reserved.
Boyer, Doug M; Seiffert, Erik R
2013-07-01
A laterally sloping fibular facet of the astragalus (=talus) has been proposed as one of few osteological synapomorphies of strepsirrhine primates, but the feature has never been comprehensively quantified. We describe a method for calculating fibular facet orientation on digital models of astragali as the angle between the planes of the fibular facet and the lateral tibial facet. We calculated this value in a sample that includes all major extant primate clades, a diversity of Paleogene primates, and nonprimate euarchontans (n = 304). Results show that previous characterization of a divide between extant haplorhines and strepsirrhines is accurate, with little overlap even when individual data points are considered. Fibular facet orientation is conserved in extant strepsirrhines despite major differences in locomotion and body size, while extant anthropoids are more variable (e.g., low values for catarrhines relative to non-callitrichine platyrrhines). Euprimate outgroups exhibit a mosaic of character states with Cynocephalus having a more obtuse strepsirrhine-like facet and sampled treeshrews and plesiadapiforms having more acute haplorhine-like facets. Surprisingly, the earliest species of the adapiform Cantius have steep haplorhine-like facets as well. We used a Bayesian approach to reconstruct the evolution of fibular facet orientation as a continuous character across a supertree of living and extinct primates. Mean estimates for crown Primatomorpha (97.9°), Primates (99.5°), Haplorhini (98.7°), and Strepsirrhini (108.2°) support the hypothesis that the strepsirrhine condition is derived, while lower values for crown Anthropoidea (92.8°) and Catarrhini (88.9°) are derived in the opposite direction. Copyright © 2013 Wiley Periodicals, Inc.
Defect Detection and Segmentation Framework for Remote Field Eddy Current Sensor Data
2017-01-01
Remote-Field Eddy-Current (RFEC) technology is often used as a Non-Destructive Evaluation (NDE) method to prevent water pipe failures. By analyzing the RFEC data, it is possible to quantify the corrosion present in pipes. Quantifying the corrosion involves detecting defects and extracting their depth and shape. For large sections of pipelines, this can be extremely time-consuming if performed manually. Automated approaches are therefore well motivated. In this article, we propose an automated framework to locate and segment defects in individual pipe segments, starting from raw RFEC measurements taken over large pipelines. The framework relies on a novel feature to robustly detect these defects and a segmentation algorithm applied to the deconvolved RFEC signal. The framework is evaluated using both simulated and real datasets, demonstrating its ability to efficiently segment the shape of corrosion defects. PMID:28984823
Defect Detection and Segmentation Framework for Remote Field Eddy Current Sensor Data.
Falque, Raphael; Vidal-Calleja, Teresa; Miro, Jaime Valls
2017-10-06
Remote-Field Eddy-Current (RFEC) technology is often used as a Non-Destructive Evaluation (NDE) method to prevent water pipe failures. By analyzing the RFEC data, it is possible to quantify the corrosion present in pipes. Quantifying the corrosion involves detecting defects and extracting their depth and shape. For large sections of pipelines, this can be extremely time-consuming if performed manually. Automated approaches are therefore well motivated. In this article, we propose an automated framework to locate and segment defects in individual pipe segments, starting from raw RFEC measurements taken over large pipelines. The framework relies on a novel feature to robustly detect these defects and a segmentation algorithm applied to the deconvolved RFEC signal. The framework is evaluated using both simulated and real datasets, demonstrating its ability to efficiently segment the shape of corrosion defects.
A delayed presentation of ameloblastic fibrosarcoma in an African patient.
Chauke, Nkhensani Yvonne; Sofianos, Chrysis; Liakos, Dimitri; Ndobe, Elias
2017-08-01
A 24-year-old womanpresented with ameloblastic fibrosarcoma arising from ameloblastic fibroma. The delayed presentation accounted for the extensive destruction of the mandible and complete occlusion of her oral cavity. This resulted in an inability to eat and maintain oral hygiene. A multidisciplinary team management approach involved nutritional optimisation, segmental mandibulectomy, reconstruction with a reconstructive plate and a free anterolateral thigh flap to line the the floor of mouth. Functional and aesthetic outcome was acceptable, and the patient is planned for secondary free fibular flap bony reconstruction. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Is fibular fracture displacement consistent with tibiotalar displacement?
van den Bekerom, Michel P J; van Dijk, C Niek
2010-04-01
We believed open reduction with internal fixation is required for supination-external rotation ankle fractures located at the level of the distal tibiofibular syndesmosis (Lauge-Hanssen SER II and Weber B) with 2 mm or more fibular fracture displacement. The rationale for surgery for these ankle fractures is based on the notion of elevated intraarticular contact pressures with lateral displacement. To diagnose these injuries, we presumed that in patients with a fibular fracture with at least 2 mm fracture displacement, the lateral malleolus and talus have moved at least 2 mm in a lateral direction without medial displacement of the proximal fibula. We reviewed 55 adult patients treated operatively for a supination-external rotation II ankle fracture (2 mm or more fibular fracture displacement) between 1990 and 1998. On standard radiographs, distance from the tibia to the proximal fibula, distance from the tibia to the distal fibula, and displacement at the level of the fibular fracture were measured. These distances were compared preoperatively and postoperatively. We concluded tibiotalar displacement cannot be reliably assessed at the level of the fracture. Based on this and other studies, we believe there is little evidence to perform open reduction and internal fixation of supination-external rotation II ankle fractures. Level IV, case series. See Guidelines for Authors for a complete description of levels of evidence.
[How to make your own custom cutting guides for both mandibular and fibular stair step osteotomies?
Rem, K; Bosc, R; De Kermadec, H; Hersant, B; Meningaud, J-P
2017-12-01
Using tailored cutting guides for osteocutaneous free fibula flap in complex mandibular reconstruction after cancer resection surgery constitutes a substantial improvement. Autonomously conceiving and manufacturing the cutting guides within a plastic surgery department with computer-aided design (CAD) and three-dimensional (3D) printing allows planning more complex osteotomies, such as stair-step osteotomies, in order to achieve more stable internal fixations. For the past three years, we have been producing by ourselves patient-tailored cutting guides using CAD and 3D printing. Osteotomies were virtually planned, making the cutting lines more complex in order to optimize the internal fixation stability. We also printed reconstructed mandible templates and shaped the reconstruction plates on them. We recorded data including manufacturing techniques and surgical outcomes. Eleven consecutive patients were operated on for an oral cavity cancer. For each patient, we planned the fibular and mandibular stair-step osteotomies and we produced tailored cutting guides. In all patients, we achieved to get immediately stable internal fixations and in 10 patients, a complete bone consolidation after 6 months. Autonomously manufacturing surgical cutting guides for mandibular reconstruction by free fibula flap is a significant improvement, regarding ergonomics and precision. Planning stair-step osteotomies to perform complementary internal fixation increases contact surface and congruence between the bone segments, thus improving the reconstructed mandible stability. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Morin, Paul M; Reindl, Rudolf; Harvey, Edward J; Beckman, Lorne; Steffen, Thomas
2008-02-01
Distal third tibia fractures have classically been treated with standard plating, but intramedullary (IM) nailing has gained popularity. Owing to the lack of interference fit of the nail in the metaphyseal bone of the distal tibia, it may be beneficial to add rigid plating of the fibula to augment the overall stability of fracture fixation in this area. This study sought to assess the biomechanical effect of adding a fibular plate to standard IM nailing in the treatment of distal third tibia and fibula fractures. Eight cadaveric tibia specimens were used. Tibial fixation consisted of a solid titanium nail locked with 3 screws distally and 2 proximally, and fibular fixation consisted of a 3.5 mm low-contact dynamic compression plate. A section of tibia and fibula was removed. Testing was accomplished with an MTS machine. Each leg was tested 3 times; with and without a fibular plate and with a repetition of the initial test condition. Vertical displacements were tested with an axial load up to 500 N, and angular rotation was tested with torques up to 5 N*m. The difference in axial rotation was the only statistically significant finding (p = 0.003), with fibular fixation resulting in 1.1 degrees less rotation through the osteotomy site (17.96 degrees v. 19.10 degrees ). Over 35% of this rotational displacement occurred at the nail-locking bolt interface with the application of small torsional forces. Fibular plating in addition to tibial IM fixation of distal third tibia and fibula fractures leads to slightly increased resistance to torsional forces. This small improvement may not be clinically relevant.
van Wessem, K J P; Leenen, L P H
2016-03-01
High fibular spiral fractures are usually caused by pronation-external rotation mechanism. The foot is in pronation and the talus externally rotates, causing a rupture of the medial ligaments or a fracture of the medial malleolus. With continued rotation the anterior and posterior tibiofibular ligament will rupture, and finally, the energy leaves the fibula by creating a spiral fracture from anterior superior to posterior inferior. In this article we demonstrate a type of ankle fracture with syndesmotic injury and high fibular spiral fractures without a medial component. This type of ankle fractures cannot be explained by the Lauge-Hansen classification, since it lacks injury on the medial side of the ankle, but it does have the fibular fracture pattern matching the pronation external rotation injury (anterior superior to posterior inferior fracture). We investigated the mechanism of this injury illustrated by 3 cases and postulate a theory explaining the biomechanics behind this type of injury. Copyright © 2016 Elsevier Ltd. All rights reserved.
Adult outcomes following amputation or lengthening for fibular deficiency.
Walker, Janet L; Knapp, Dwana; Minter, Christin; Boakes, Jennette L; Salazar, Juan Carlos; Sanders, James O; Lubicky, John P; Drvaric, David M; Davids, Jon R
2009-04-01
Fibular deficiency results in a small, unstable foot and ankle as well as a limb-length discrepancy. The purpose of this study was to assess outcomes in adults who, as children, had had amputation or limb-lengthening, commonly used treatments for fibular deficiency. Retrospective review of existing data collected since 1950 at six pediatric orthopaedic centers identified 248 patients with fibular deficiency who were twenty-one years of age or older at the time of the review. Excluding patients with other anomalies and other treatments (with the excluded group including six who had had lengthening and then amputation), we identified ninety-eight patients who had had amputation or limb-lengthening for the treatment of isolated unilateral fibular deficiency. Sixty-two patients (with thirty-six amputations and twenty-six lengthening procedures) completed several questionnaires, including one asking general demographic questions, the Beck Depression Inventory-II, the Quality of Life Questionnaire, and the American Academy of Orthopaedic Surgeons Lower Limb Questionnaire including the Short Form-36. A group of twenty-eight control subjects completed the Beck Depression Inventory-II and the Quality of Life Questionnaire. There were forty men and twenty-two women. The average age at the time of the interview was thirty-three years. There were more amputations in those with fewer rays and less fibular preservation. Lengthening resulted in more surgical procedures (6.3 compared with 2.4 in patients treated with amputation) and more days in the hospital (184 compared with sixty-three) (both p<0.0001). However, when we compared treatment outcomes we did not find differences between groups with regard to education, employment, income, public assistance or disability payments, pain or use of pain medicine, sports participation, activity restriction, comfort wearing shorts, dislike of limb appearance, or satisfaction with treatment. No patient who had been treated for fibular deficiency reported signs of depression. The only significant difference between treatment groups shown by the Quality of Life Questionnaire was in the scores on the Job Satisfiers content scale, with the amputees scoring better than the patients treated with lengthening (p=0.015). The American Academy of Orthopaedic Surgeons Lower Limb Module did not demonstrate differences in health-related quality of life or physical function. The patients who were treated with lengthening had started out with more residual foot rays and more fibular preservation than the amputees. They also required more surgical intervention than did those with an amputation. While patients with an amputation spent less of their childhood undergoing treatment, they were found to have a better outcome in terms of only one of seventeen quality-of-life parameters. Both groups of patients who had had treatment of fibular deficiency were functioning at high levels, with an average to above-average quality of life compared with that of the normal adult population.
Khani, Ghulam Mustafa Kaim; Hafeez, Kamran; Bux, Muhammad; Rasheed, Nusrat; Ahmed, Naveed; Anjum, M Perwez
2017-01-01
To present the clinical outcome of patients with neglected femur neck fracture treated with fibular bone graft. During May 2010-February 2013, 15 patients younger than 35 years of age with neglected fracture neck of femur were managed with non-vascularized fibular graft and cannulated screws. Fractures were classified according to Sandhu Classification. Hip function was assessed using Harris hip score. Fifteen patients with mean age of 28.67 years were managed. Mean period of delay from injury to presentation was 3.07 months. Mean follow-up was 18.5 months. Union was achieved in 13 cases. 2 patients developed nonunion with progression of avascular necrosis (AVN). Patients with healed fracture did not show radiological signs of AVN till the past follow-up. Functional status was evaluated at 6 months according to Harris hip score and was poor in 2 patients, fair in 2 patients, good in 6 patients, and excellent in 5 patients. Fibular graft along with two cancellous screws proved to be an effective technique in our cases with neglected femur neck fractures.
Vamsi, K.; Rao, Sharath K.; Gnanadoss, James J.; Pandian, S.
2008-01-01
Humeral shaft fractures respond well to conservative treatment and unite without much problem. Since it is uncommon, there is not much discussion regarding the management of nonunion in the literature, and hence this is a challenge to the treating orthopaedic surgeon. Osteoporosis of the fractured bone and stiffness of the surrounding joints compounds the situation further. The Ilizarov fixator, locking compression plate, and vascularised fibular graft are viable options in this scenario but are technically demanding. We used a fibular strut graft for bridging the fracture site in order to enhance the pull-out strength of the screws of the dynamic compression plate. Six patients in the study had successful uneventful union of the fracture at the last follow-up. The fibula is easy to harvest and produces less graft site morbidity. None of the study patients needed additional iliac crest bone grafting. This is the largest reported series of patients with osteoporotic atrophic nonunion of humerus successfully treated solely using the combination of an intramedullary fibular strut graft and dynamic compression plate. PMID:18563410
Wang, Tie-Jun; Ju, Wei-Na; Qi, Bao-Chang
2017-03-01
Anatomical characteristics, such as subcutaneous position and minimal muscle cover, contribute to the complexity of fractures of the distal third of the tibia and fibula. Severe damage to soft tissue and instability ensure high risk of delayed bone union and wound complications such as nonunion, infection, and necrosis. This case report discusses management in a 54-year-old woman who sustained fractures of the distal third of the left tibia and fibula, with damage to overlying soft tissue (swelling and blisters). Plating is accepted as the first choice for this type of fracture as it ensures accurate reduction and rigid fixation, but it increases the risk of complications. Closed fracture of the distal third of the left tibia and fibula (AO: 43-A3). After the swelling was alleviated, the patient underwent closed reduction and fixation with an Acumed fibular nail and minimally invasive plating osteosynthesis (MIPO), ensuring a smaller incision and minimal soft-tissue dissection. At the 1-year follow-up, the patient had recovered well and had regained satisfactory function in the treated limb. The Kofoed score of the left ankle was 95. Based on the experience from this case, the operation can be undertaken safely when the swelling has been alleviated. The minimal invasive technique represents the best approach. Considering the merits and good outcome in this case, we recommend the Acumed fibular nail and MIPO technique for treatment of distal tibial and fibular fractures.
Suga, Kazuyoshi; Yasuhiko, Kawakami; Iwanaga, Hideyuki; Tokuda, Osamu; Matsunaga, Naofumi
2008-09-01
The relation between lung perfusion defects and intravascular clots in acute pulmonary thromboembolism (PTE) was comprehensively assessed on deep-inspiratory breath-hold (DIBrH) perfusion SPECT-computed tomographic pulmonary angiography (CTPA) fusion images. Subjects were 34 acute PTE patients, who had successfully performed DIBrH perfusion SPECT using a dual-headed SPECT and a respiratory tracking system. Automated DIBrH SPECT-CTPA fusion images were used to assess the relation between lung perfusion defects and intravascular clots detected by CTPA. DIBrH SPECT visualized 175 lobar/segmental or subsegmental defects in 34 patients, and CTPA visualized 61 intravascular clots at variable locations in 30 (88%) patients, but no clots in four (12%) patients. In 30 patients with clots, the fusion images confirmed that 69 (41%) perfusion defects (20 segmental, 45 subsegmental and 4 lobar defects) of total 166 defects were located in lung territories without clots, although the remaining 97 (58%) defects were located in lung territories with clots. Perfusion defect was absent in lung territories with clots (one lobar branch and three segmental branches) in four (12%) of these patients. In four patients without clots, nine perfusion defects including four segmental ones were present. Because of unexpected dissociation between intravascular clots and lung perfusion defects, the present fusion images will be a useful adjunct to CTPA in the diagnosis of acute PTE.
Algorithmic structural segmentation of defective particle systems: a lithium-ion battery study.
Westhoff, D; Finegan, D P; Shearing, P R; Schmidt, V
2018-04-01
We describe a segmentation algorithm that is able to identify defects (cracks, holes and breakages) in particle systems. This information is used to segment image data into individual particles, where each particle and its defects are identified accordingly. We apply the method to particle systems that appear in Li-ion battery electrodes. First, the algorithm is validated using simulated data from a stochastic 3D microstructure model, where we have full information about defects. This allows us to quantify the accuracy of the segmentation result. Then we show that the algorithm can successfully be applied to tomographic image data from real battery anodes and cathodes, which are composed of particle systems with very different morpohological properties. Finally, we show how the results of the segmentation algorithm can be used for structural analysis. © 2017 The Authors Journal of Microscopy © 2017 Royal Microscopical Society.
Cai, Lei; Wang, Qian; Gu, Congmin; Wu, Jingguo; Wang, Jian; Kang, Ning; Hu, Jiewei; Xie, Fang; Yan, Li; Liu, Xia; Cao, Yilin; Xiao, Ran
2011-11-01
Bone tissue engineering (BTE) has been demonstrated an effective approach to generate bone tissue and repair bone defect in ectopic and orthotopic sites. The strategy of using a prevascularized tissue-engineered bone grafts (TEBG) fabricated ectopically to repair bone defects, which is called live bone graft surgery, has not been reported. And the quantitative advantages of vascularization and osteogenic environment in promoting engineered bone formation have not been defined yet. In the current study we generated a tissue engineered bone flap with a vascular pedicle of saphenous arteriovenous in which an organized vascular network was observed after 4 weeks implantation, and followed by a successful repaire of fibular defect in beagle dogs. Besides, after a 9 months long term observation of engineered bone formation in ectopic and orthotopic sites, four CHA (coral hydroxyapatite) scaffold groups were evaluated by CT (computed tomography) analysis. By the comparison of bone formation and scaffold degradation between different groups, the influences of vascularization and micro-environment on tissue engineered bone were quantitatively analyzed. The results showed that in the first 3 months vascularization improved engineered bone formation by 2 times of non-vascular group and bone defect micro-environment improved it by 3 times of ectopic group, and the CHA-scaffold degradation was accelerated as well. Copyright © 2011 Elsevier Ltd. All rights reserved.
Kwak, Yoon-Hae; Lim, Jae-Young; Oh, Min-Kyung; Kim, Woo-Jin; Park, Kun-Bo
2015-06-01
Skeletally immature children with ankle sprain are presumed to have distal fibula fracture than ligamentous injury. The purpose of this study is to determine the incidence of associated occult avulsion fracture in children with lateral ankle sprain and the efficacy of identifying fractures using anterior talofibular ligament view. Patients who were diagnosed with distal fibular fracture in the initial ankle anteroposterior, lateral, and mortise were excluded and 78 patients (below 16 y of age) who had been initially diagnosed as ankle sprain were included. The initial and 4 weeks' follow-up ankle series and additional anterior talofibular ligament view suggested by Haraguchi were evaluated. Twenty patients were diagnosed with occult distal fibular avulsion fracture. Ten patients were diagnosed in anterior talofibular ligament view and others were diagnosed in the follow-up radiography. Displacement was highest on the anterior talofibular ligament view. This study found 20 (26%) of 78 ankle sprain show occult avulsion fracture in the anterior talofibular ligament view or follow-up radiography. The anterior talofibular ligament view is an appropriate radiologic view for the diagnosis of distal fibular avulsion fracture. Level IV--diagnostic study.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bodin, L.; Rouby, J.J.; Viars, P.
1988-07-01
Fifty five patients suffering from blunt chest trauma were studied to assess the diagnosis of myocardial contusion using thallium 201 myocardial scintigraphy. Thirty-eight patients had consistent scintigraphic defects and were considered to have a myocardial contusion. All patients with scintigraphic defects had paroxysmal arrhythmias and/or ECG abnormalities. Of 38 patients, 32 had localized ST-T segment abnormalities; 29, ST-T segment abnormalities suggesting involvement of the same cardiac area as scintigraphic defects; 21, echocardiographic abnormalities. Sixteen patients had segmental hypokinesia involving the same cardiac area as the scintigraphic defects. Fifteen patients had clinical signs suggestive of myocardial contusion and scintigraphic defects. Almostmore » 70 percent of patients with blunt chest trauma had scintigraphic defects related to areas of myocardial contusion. When thallium 201 myocardial scintigraphy directly showed myocardial lesion, two-dimensional echocardiography and standard ECG detected related functional consequences of cardiac trauma.« less
Amirouche, Farid; Solitro, Giovanni F; Walia, Amit; Gonzalez, Mark; Bobko, Aimee
2017-08-01
Management of segmental rim defects and bone mineral density (BMD) loss in the elderly prior to total hip replacement is unclear within classification systems for acetabular bone loss. In this study, our objectives were (1) to understand how a reduction in BMD in the elderly affects the oversizing of a press-fit cup for primary fixation and (2) to evaluate whether the location of the segmental defect affected cup fixation. A finite element (FE) model was used to simulate and evaluate cup insertion and fixation in the context of segmental rim defects. We focused on the distribution of patients over age 70 and used BMD (estimated from CT) as a proxy for aging's implications on THR and used probabilistic FE analysis to understand how BMD loss affects oversizing of a press-fit cup. A cup oversized by 1.10 ± 0.28 mm provides sufficient fixation and lower stresses at the cup-bone interface for elderly patients. Defects in the anterior column and posterior column both required the same mean insertion force for cup seating of 84% (taken as an average of 2 anterior column and 2 posterior column defects) compared to the control configuration, which was 5% greater than the insertion force for a superior rim defect and 12% greater than the insertion force for an inferior rim defect. A defect along the superior or inferior rim had a minimal effect on cup fixation, while a defect in the columns created cup instability and increased stress at the defect location.
SOLOMON, L. B.; FERRIS, L.; TEDMAN, R.; HENNEBERG, M.
2001-01-01
The aim of this study was to investigate the risk and to analyse the significance of laceration of the sural and superficial fibular nerves during the surgical approach to the lateral malleolus. The sural and the superficial fibular nerves, and their branches were dissected under ×3 magnifying lenses in 68 embalmed leg-ankle-foot specimens. The specimens were measured, drawn and photographed. In 35% of specimens the superficial fibular nerve branched before piercing the crural fascia, and in all these specimens the medial dorsal cutaneous nerve of the foot was located in the anterior compartment while the intermediate dorsal cutaneous nerve of the foot was located in the lateral compartment. In 35% of specimens the intermediate dorsal cutaneous nerve of the foot was absent or did not innervate any toe. The deep part of the superficial fibular nerve was in contact with the intermuscular septum. Its superficial part was parallel with the lateral malleolus when the nerve pierced the fascia more proximally and oblique to the lateral malleolus when the nerve pierced the fascia distally. In one case the intermediate dorsal cutaneous nerve of the foot was in danger of laceration during a subcutaneous incision to the lateral malleolus. In 7 cases (10%) the sural nerve overlapped or was tangent to the tip of the malleolus. Malleolar nerve branches were identified in 76% of the cases (in 28% from both sources). The sural nerve supplies the lateral 5 dorsal digital nerves in 40% of cases. Our study indicates that during the approach to the lateral malleolus there is a high risk of laceration of malleolar branches from both the sural and the superficial fibular nerves. There is less risk of damage to the main trunk of these nerves, but the 10% chance of laceration of sural nerve at the tip of the malleolus is significant. As the sural nerve supplies the superficial innervation to the lateral half of the foot and toes in 40% of cases, the risk of its laceration is even more important than indicated by the common anatomical teaching. PMID:11787825
Mohanty, S P; Singh, K A; Kundangar, R; Shankar, V
2017-04-01
The purpose of this study was to compare the clinical and radiological outcomes of multiple small diameter drilling and core decompression with fibular strut grafting in the management of non-traumatic avascular necrosis (AVN) of the femoral head. Outcomes of patients with AVN treated by multiple small diameter drilling (group 1) were compared retrospectively with patients treated by core decompression and fibular grafting (group 2). Harris hip score (HHS) was used to assess the clinical status pre- and postoperatively. Modified Ficat and Arlet classification was used to assess the radiological stage pre- and postoperatively. Forty-six patients (68 hips) were included in this study. Group 1 consisted of 33 hips, and group 2 consisted of 35 hips. In stages I and IIB, there was no statistically significant difference in the final HHS between the two groups. However, in stages IIA and III, hips in group 2 had a better final HHS (P < 0.05). In terms of radiographic progression, there was no statistical difference between hips in stages I, IIA and stage IIB. However, in stage III, hips belonging to group 2 had better results (P < 0.05). Kaplan-Meier survivorship analysis showed better outcome in group 2 in stage III (P < 0.05). Hips with AVN in the precollapse stage can be salvaged by core decompression with or without fibular grafting. Multiple small diameter drilling is relatively simple and carries less morbidity and hence preferred in stages I and II. However, in stage III disease, core decompression with fibular strut grafting gives better results.
Ricci, R Daniel; Cerullo, James; Blanc, Robert O; McMahon, Patrick J; Buoncritiani, Anthony M; Stone, David A; Fu, Freddie H
2008-01-01
Objective: To present the case of a talocrural dislocation with a Weber type C fibular fracture in a National Collegiate Athletic Association Division I football athlete. Background: The athlete, while attempting to make a tackle during a game, collided with an opponent, who in turn stepped on the lateral aspect of the athlete's ankle, resulting in forced ankle eversion and external rotation. On-field evaluation showed a laterally displaced talocrural dislocation. Immediate reduction was performed in the athletic training room to maintain skin integrity. Post-reduction radiographs revealed a Weber type C fibular fracture and increased medial joint clear space. A below-knee, fiberglass splint was applied to stabilize the ankle joint complex. Differential Diagnosis: Subtalar dislocation, Maisonneuve fracture, malleolar fracture, deltoid ligament rupture, syndesmosis disruption. Treatment: The sports medicine staff immediately splinted and transported the athlete to the athletic training room to reduce the dislocation. The athlete then underwent an open reduction and internal fixation procedure to stabilize the injury: 2 syndesmosis screws and a fibular plate were placed to keep the ankle joint in an anatomically reduced position. With the guidance of the athletic training staff, the athlete underwent an accelerated physical rehabilitation protocol in an effort to return to sport as quickly and safely as possible. Uniqueness: Most talocrural dislocations and associated Weber type C fibular fractures are due to motor vehicle accidents or falls. We are the first to describe this injury in a Division I football player and to present a general rehabilitation protocol for a high-level athlete. Conclusions: Sports medicine practitioners must recognize that this injury can occur in the athletic environment. Prompt reduction, early surgical intervention, sufficient resources, and an accelerated rehabilitation protocol all contributed to a successful outcome in the patient. PMID:18523569
Evaluation of the syndesmotic-only fixation for Weber-C ankle fractures with syndesmotic injury.
Mohammed, R; Syed, S; Metikala, S; Ali, Sa
2011-09-01
With the length of the fibula restored and the syndesmosis reduced anatomically, internal fixation using a plating device may not be necessary for supra-syndesmotic fibular fractures combined with diastasis of inferior tibio-fibular joint. A retrospective observational study was performed in patients who had this injury pattern treated with syndesmosis-only fixation. 12 patients who had Weber type-C injury pattern were treated with syndesmosis only fixation. The treatment plan was followed only if the fibular length could be restored and if the syndesmosis could be anatomically reduced. Through a percutaneous or mini-open reduction and clamp stabilization of the syndesmosis, all but one patient had a single tricortical screw fixation across the syndesmosis. Patients were kept non-weight-bearing for 6 weeks, followed by screw removal at an average of 8 weeks. Outcomes were assessed using an objective ankle scoring system (Olerud and Molander scale) and by radiographic assessment of the ankle mortise. At a mean follow-up of 13 months, the functional outcome score was 75. Excellent to good outcomes were noted in 83% of the patients. Ankle mortise was reduced in all cases, and all but one fibular fracture united without loss of fixation. Six patients had more than one malleolar injury, needing either screw or anchor fixations. One patient had late diastasis after removal of the syndesmotic screw and underwent revision surgery with bone grafting of the fibula. This was probably due to early screw removal, before union of the fibular fracture had occurred. We recommend syndesmosis-only fixation as an effective treatment option for a combination of syndesmosis disruption and Weber type-C lateral malleolar fractures.
Evaluation of the syndesmotic-only fixation for Weber-C ankle fractures with syndesmotic injury
Mohammed, R; Syed, S; Metikala, S; Ali, SA
2011-01-01
Background: With the length of the fibula restored and the syndesmosis reduced anatomically, internal fixation using a plating device may not be necessary for supra-syndesmotic fibular fractures combined with diastasis of inferior tibio-fibular joint. A retrospective observational study was performed in patients who had this injury pattern treated with syndesmosis-only fixation. Materials and Methods: 12 patients who had Weber type-C injury pattern were treated with syndesmosis only fixation. The treatment plan was followed only if the fibular length could be restored and if the syndesmosis could be anatomically reduced. Through a percutaneous or mini-open reduction and clamp stabilization of the syndesmosis, all but one patient had a single tricortical screw fixation across the syndesmosis. Patients were kept non-weight-bearing for 6 weeks, followed by screw removal at an average of 8 weeks. Outcomes were assessed using an objective ankle scoring system (Olerud and Molander scale) and by radiographic assessment of the ankle mortise. Results: At a mean follow-up of 13 months, the functional outcome score was 75. Excellent to good outcomes were noted in 83% of the patients. Ankle mortise was reduced in all cases, and all but one fibular fracture united without loss of fixation. Six patients had more than one malleolar injury, needing either screw or anchor fixations. One patient had late diastasis after removal of the syndesmotic screw and underwent revision surgery with bone grafting of the fibula. This was probably due to early screw removal, before union of the fibular fracture had occurred. Conclusion: We recommend syndesmosis-only fixation as an effective treatment option for a combination of syndesmosis disruption and Weber type-C lateral malleolar fractures. PMID:21886929
Chen, Xiaoping; Song, Fengyu; Jhamb, Deepali; Li, Jiliang; Bottino, Marco C.; Palakal, Mathew J.; Stocum, David L.
2015-01-01
We tested the ability of the axolotl (Ambystoma mexicanum) fibula to regenerate across segment defects of different size in the absence of intervention or after implant of a unique 8-braid pig small intestine submucosa (SIS) scaffold, with or without incorporated growth factor combinations or tissue protein extract. Fractures and defects of 10% and 20% of the total limb length regenerated well without any intervention, but 40% and 50% defects failed to regenerate after either simple removal of bone or implanting SIS scaffold alone. By contrast, scaffold soaked in the growth factor combination BMP-4/HGF or in protein extract of intact limb tissue promoted partial or extensive induction of cartilage and bone across 50% segment defects in 30%-33% of cases. These results show that BMP-4/HGF and intact tissue protein extract can promote the events required to induce cartilage and bone formation across a segment defect larger than critical size and that the long bones of axolotl limbs are an inexpensive model to screen soluble factors and natural and synthetic scaffolds for their efficacy in stimulating this process. PMID:26098852
[Interposition arthrodesis of the ankle].
Vienne, Patrick
2005-10-01
Bony fusion of the ankle in a functionally favorable position for restitution of a painless weight bearing while avoiding a leg length discrepancy. Disabling, painful osteoarthritis of the ankle with extensive bone defect secondary to trauma, infection, or serious deformities such as congenital malformations or diabetic osteoarthropathies. Acute joint infection. Severe arterial occlusive disease of the involved limb. Lateral approach to the distal fibula. Fibular osteotomy 7 cm proximal to the tip of the lateral malleolus and posterior flipping of the distal fibula. Exposure of the ankle. Removal of all articular cartilage and debridement of the bone defect. Determination of the size of the defect and harvesting of a corresponding tricortical bone graft from the iliac crest. Also harvesting of autogenous cancellous bone either from the iliac crest or from the lateral part of the proximal tibia. Insertion of the tricortical bone graft and filling of the remaining defect with cancellous bone. Fixation with three 6.5-mm titanium lag screws. Depending on the extent of the defect additional stabilization of the bone graft with a titanium plate. Fixation of the lateral fibula on talus and tibia with two 3.5-mm titanium screws for additional support. Wound closure in layers. Split below-knee cast with the ankle in neutral position. Between January 2002 and January 2004 this technique was used in five patients with extensive bone defects (four women, one man, average age 57 years [42-77 years]). No intra- or early postoperative complications. The AOFAS (American Orthopedic Foot and Ankle Society) Score was improved from 23 points preoperatively to 76 points postoperatively (average follow-up time of 25 months). Two patients developed a nonunion and underwent a revision with an ankle arthrodesis nail. A valgus malposition after arthrodesis in one patient was corrected with a supramalleolar osteotomy.
Effects of laser therapy in peripheral nerve regeneration
Sene, Giovana Almeida Leitão; Sousa, Fausto Fernandes de Almeida; Fazan, Valéria Sassoli; Barbieri, Cláudio Henrique
2013-01-01
OBJECTIVE: The influence of dose of low power lasertherapy (AsGaAl, 830 nm) on the regeneration of the fibular nerve of rats after a crush injury was evaluated by means of the functional gait analysis and histomorphometric parameters. METHODS: Controlled crush injury of the right common fibular nerve, immediately followed by increasing doses (G1: no irradiation; G2: simulated; G3: 5 J/cm2; G4: 10 J/cm2; G5: 20 J/cm2) laser irradiation directly on the lesion site for 21 consecutive days. Functional gait analysis was carried out at weekly intervals by measuring the peroneal/fibular functional index (PFI). The animals were killed on the 21st postoperative day for removal of the fibular nerve, which was prepared for the histomorphometric analysis. RESULTS: The PFI progressively increased during the observation period in all groups, without significant differences between them (p>0.05). The transverse nerve area was significantly wider in group 2 than in groups 3 and 4, while fiber density was significantly greater in group 4 than in all remaining groups. CONCLUSION: The low power AsGaAl laser irradiation did not accelerate nerve recovery with any of the doses used. Level of Evidence I, Therapeutic Studies Investigating the Results of Treatment. PMID:24453680
NASA Astrophysics Data System (ADS)
Su, Tengfei
2018-04-01
In this paper, an unsupervised evaluation scheme for remote sensing image segmentation is developed. Based on a method called under- and over-segmentation aware (UOA), the new approach is improved by overcoming the defect in the part of estimating over-segmentation error. Two cases of such error-prone defect are listed, and edge strength is employed to devise a solution to this issue. Two subsets of high resolution remote sensing images were used to test the proposed algorithm, and the experimental results indicate its superior performance, which is attributed to its improved OSE detection model.
Conservative treatment of injury to the fibular ligaments of the ankle.
Cetti, R.
1982-01-01
Fifty-one patients with fibular ligamentous injury of the ankle are presented. The treatment consisted of complete non-weight-bearing of the affected foot by use of elbow crutches for three weeks. All patients were seen at follow-up eighteen months after the accident. The results are discussed in the light of previous literature on conservative and operative treatment of lateral ligament injuries. Images p47-a PMID:6802213
Kosiol, J; Wille, M; Putzer, D; Biedermann, R
2015-11-01
An acute ligament rupture of the lateral ligament complex of the ankle joint is treated without surgery. Treatment failure may lead to a chronically unstable situation of the ankle joint, in which case surgery is an effective procedure for stabilizing the ruptured ligaments. Anatomical reconstruction is the best operative technique if the ligament tissue is of good quality. In our video we demonstrate a new possibility for the positioning of an anchor to tighten the calcaneo-fibular ligament. Modified Broström repairs are described in the literature in which the calcaneo-fibular ligament is released and reattached to the fibula to tighten it. We present the option to release the ligament at the calcaneus and reattach it using a suture anchor. This offers the advantage of preventing the possible dislocation of the peroneal tendons.
Husser, Oliver; Monmeneu, Jose V; Bonanad, Clara; Lopez-Lereu, Maria P; Nuñez, Julio; Bosch, Maria J; Garcia, Carlos; Sanchis, Juan; Chorro, Francisco J; Bodi, Vicente
2014-09-01
The incremental prognostic value of inducible myocardial ischemia over necrosis derived by stress cardiac magnetic resonance in depressed left ventricular function is unknown. We determined the prognostic value of necrosis and ischemia in patients with depressed left ventricular function referred for dipyridamole stress perfusion magnetic resonance. In a multicenter registry using stress magnetic resonance, the presence (≥ 2 segments) of late enhancement and perfusion defects and their association with major events (cardiac death and nonfatal infarction) was determined. In 391 patients, perfusion defect or late enhancement were present in 224 (57%) and 237 (61%). During follow-up (median, 96 weeks), 47 major events (12%) occurred: 25 cardiac deaths and 22 myocardial infarctions. Patients with major events displayed a larger extent of perfusion defects (6 segments vs 3 segments; P <.001) but not late enhancement (5 segments vs 3 segments; P =.1). Major event rate was significantly higher in the presence of perfusion defects (17% vs 5%; P =.0005) but not of late enhancement (14% vs 9%; P =.1). Patients were categorized into 4 groups: absence of perfusion defect and absence of late enhancement (n = 124), presence of late enhancement and absence of perfusion defect (n = 43), presence of perfusion defect and presence of late enhancement (n = 195), absence of late enhancement and presence of perfusion defect (n = 29). Event rate was 5%, 7%, 16%, and 24%, respectively (P for trend = .003). In a multivariate regression model, only perfusion defect (hazard ratio = 2.86; 95% confidence interval, 1.37-5.95]; P = .002) but not late enhancement (hazard ratio = 1.70; 95% confidence interval, 0.90-3.22; P =.105) predicted events. In depressed left ventricular function, the presence of inducible ischemia is the strongest predictor of major events. Copyright © 2014 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.
Distal Insertions of the Biceps Femoris
Branch, Eric A.; Anz, Adam W.
2015-01-01
Background: Avulsion of the biceps femoris from the fibula and proximal tibia is encountered in clinical practice. While the anatomy of the primary posterolateral corner structures has been qualitatively and quantitatively described, a quantitative analysis regarding the insertions of the biceps femoris on the fibula and proximal tibia is lacking. Purpose: To quantitatively assess the insertions of the biceps femoris, fibular collateral ligament (FCL), and anterolateral ligament (ALL) on the fibula and proximal tibia as well as establish relationships among these structures and to pertinent surgical anatomy. Study Design: Descriptive laboratory study. Methods: Dissections were performed on 12 nonpaired, fresh-frozen cadaveric specimens identifying the biceps femoris, FCL, and ALL, and their insertions on the proximal tibia and fibula. The footprint areas, orientations, and distances from relevant osseous landmarks were measured using a 3-dimensional coordinate measurement device. Results: Dissection produced 6 easily identifiable and reproducible anatomic footprints. Tibial footprints included the insertion of the ALL and an insertion of the biceps femoris (TBF). Fibular footprints included the insertion of the FCL, a distal insertion of the biceps femoris (DBF), a medial footprint of the biceps femoris (MBF), and a proximal footprint of the biceps femoris (PBF). The mean area of these footprints (95% CI) was as follows: ALL, 53.0 mm2 (38.4-67.6); TBF, 93.9 mm2 (72.0-115.8); FCL, 86.8 mm2 (72.3-101.2); DBF, 119 mm2 (91.1-146.9); MBF, 46.8 mm2 (29.0-64.5); and PBF, 215 mm2 (192.4-237.5). The mean distance (95% CI) from the Gerdy tubercle to the center of the ALL footprint was 24.3 mm (21.6-27.0) and to the center of the TBF was 22.5 mm (21.0-24.0). The center of the DBF was 8.68 mm (7.0-10.3) from the anterior border of the fibula, the center of the FCL was 14.6 mm (12.5-16.7) from the anterior border of the fibula and 20.7 mm (19.0-22.4) from the tip of the fibular styloid, and the center of the PBF was 8.96 mm (8.2-9.7) from the tip of the fibular styloid. Conclusion: A tibial footprint, distal fibular footprint, medial fibular footprint, and proximal fibular footprint were all consistent components of the insertion of the biceps femoris. Consistent relationships existed between the biceps femoris and insertions of the ALL and FCL. Clinical Relevance: The size of these footprints and distances from pertinent surgical landmarks will guide repairs of biceps femoris avulsion injuries. PMID:26535398
The many faces of intraosseous haemangioma: a diagnostic headache.
Ching, B C; Wong, J S; Tan, M H; Jara-Lazaro, A R
2009-05-01
Intraosseous haemangioma constitutes less than ten percent of all primary bone neoplasms. Approximately 75 percent occur in the calvarium or vertebrae, with long bones, short tubular bones and ribs constituting the rest. We describe a 52-year-old woman who presented with left knee pain for 4-5 years and loss of weight over one week. An initial radiograph of the knee showed several well circumscribed isodense lesions with sclerotic rims in the medullary cavity of the distal femur and diaphysis of the left tibia. There were also lucent lesions with a slightly sclerotic rim in the diaphysis of the left tibia and proximal left fibula. In view of the clinical presentation and radiological findings, extensive investigations were made to rule out metastases and multiple myeloma. An open biopsy with segmental osteotomy of the left mid fibular lesion revealed an intraosseous haemangioma.
Application of Morphological Segmentation to Leaking Defect Detection in Sewer Pipelines
Su, Tung-Ching; Yang, Ming-Der
2014-01-01
As one of major underground pipelines, sewerage is an important infrastructure in any modern city. The most common problem occurring in sewerage is leaking, whose position and failure level is typically idengified through closed circuit television (CCTV) inspection in order to facilitate rehabilitation process. This paper proposes a novel method of computer vision, morphological segmentation based on edge detection (MSED), to assist inspectors in detecting pipeline defects in CCTV inspection images. In addition to MSED, other mathematical morphology-based image segmentation methods, including opening top-hat operation (OTHO) and closing bottom-hat operation (CBHO), were also applied to the defect detection in vitrified clay sewer pipelines. The CCTV inspection images of the sewer system in the 9th district, Taichung City, Taiwan were selected as the experimental materials. The segmentation results demonstrate that MSED and OTHO are useful for the detection of cracks and open joints, respectively, which are the typical leakage defects found in sewer pipelines. PMID:24841247
Pneumaticos, Spyros G; Triantafyllopoulos, Georgios K; Basdra, Efthimia K; Papavassiliou, Athanasios G
2010-01-01
Abstract Several conditions in clinical orthopaedic practice can lead to the development of a diaphyseal segmental bone defect, which cannot heal without intervention. Segmental bone defects have been traditionally treated with bone grafting and/or distraction osteogenesis, methods that have many advantages, but also major drawbacks, such as limited availability, risk of disease transmission and prolonged treatment. In order to overcome such limitations, biological treatments have been developed based on specific pathways of bone physiology and healing. Bone tissue engineering is a dynamic field of research, combining osteogenic cells, osteoinductive factors, such as bone morphogenetic proteins, and scaffolds with osteoconductive and osteoinductive attributes, to produce constructs that could be used as bone graft substitutes for the treatment of segmental bone defects. Scaffolds are usually made of ceramic or polymeric biomaterials, or combinations of both in composite materials. The purpose of the present review is to discuss in detail the molecular and cellular basis for the development of bone tissue engineering constructs. PMID:20345845
Outcome of locking compression plates in humeral shaft nonunions
Kumar, Malhar N; Ravindranath, V Pratap; Ravishankar, MR
2013-01-01
Background: Nonunion of diaphyseal fractures of the humerus are frequently seen in clinical practice (incidence of up to 15% in certain studies) and osteosynthesis using dynamic compression plates, intra medullary nails and Ilizarov fixators have been reported previously. Locking compression plates (LCP) are useful in the presence of disuse osteoporosis, segmental bone loss and cortical defects that preclude strong fixation. We report a prospective followup study of the outcome of the use of LCP for humeral nonunion following failed internal fixation in which implants other than LCP had been used. Materials and Methods: Twenty four patients with nonunion of humeral shaft fractures following failed internal fixation were included in the study. The mean followup period was 3.4 years (range: 2.4 to 5.7 years) and the minimum followup period was 2 years. Mean age of the patients was 41.04 years (range: 24 to 57 years). All 24 patients underwent osteosynthesis using LCP and autologous bone grafting (cortico-cancellous iliac crest graft combined with or without fibular strut graft). Main outcome measurements included radiographic assessment of fracture union and pre and postoperative functional evaluation using the modified Constant and Murley scoring system. Results: 23 out of 24 fractures united following osteosynthesis. Average time to union was 16 weeks (range: 10 to 28 weeks). Complications included delayed union (n = 2), transient radial nerve palsy (n = 2) and persistent nonunion (n = 1). Functional evaluation using the Constant and Murley score showed excellent results in 11, good in 10, fair in two and poor outcome in one patient. Conclusions: Locking compression plating and cancellous bone grafting is a reliable option for achieving union in humeral diaphyseal nonunion with failed previous internal fixation and results in good functional outcome in patients with higher physiological demands. PMID:23682176
Repair of defects and osteosynthesis of long bones in children with osteoclastoma
NASA Astrophysics Data System (ADS)
Ryzhikov, D. V.; Gubina, E. V.; Podorozhnaya, V. T.; Senchenko, E. V.; Sadovoy, M. A.
2016-08-01
The paper is aimed at reporting a retrospective analysis covering the period from 2007 to 2015. The study involved 22 patients with benign osteoclastoma (OC), 14 male and 8 female children aged 9 to 19. All patients had monostotic lesions with the following location of pathological foci: humerus—11 patients, femoral bone—7, shin bone— 1, fibular bone—1, and ulnar bone—1. All 22 patients underwent surgery. Surgical treatment included resection of tumor focus within intact tissues (in cases of eccentric foci, bony bridge was preserved in the area of minimum damage, which was treated by electrocoagulation together with the cavity) together with bone grafting and intramedullary reinforcement of the affected bone (which provides stable osteosynthesis, early mobilization, and prevention of functional deficits in most patients). Consolidation was achieved in 100% of the operated patients.
Repair of tracheomalacia with inflammatory defect and mediastinitis.
Sandu, Kishore; Monnier, Yan; Hurni, Michel; Bernath, Marc-Andre; Monnier, Philippe; Wang, Yabo; Ris, Hans-Beat
2011-01-01
We describe a novel repair of an anterior inflammatory tracheal defect with mediastinitis, which occurred after external tracheal suspension of localized intrathoracic tracheomalacia. The malacic tracheal segment of 4-cm length containing the inflammatory tracheal defect was noncircumferentially resected. A temporary endotracheal silicone stent was introduced, and the trachea was closed by a pedicled pectoralis muscle flap reinforced with an embedded rib segment. Retrieval of the stent 5 months postoperatively resulted in a re-epithelialized, persistently stable, noncollapsible tracheal segment that showed the same diameter and configuration as the nonreconstructed part of the trachea. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Sanchez, Gerardo; Lopez, Jaime; Perez, Adrian; Naal, Norberto
2013-01-01
Chondroblastomas are rare entities accounting for approximately 1% of all primary bone tumors. We describe a case of a 7-year-old girl with a giant chondroblastoma of the maxilla, treated with bilateral class III maxillectomy and reconstruction with a double-barreled and double skin paddle fibular free flap. We show evidence of an excellent aesthetic outcome at 6 months' follow up with no evidence of tumor recurrence. PMID:24286054
Internal Prosthetic Replacement of Skeletal Segments Lost in Combat Injuries.
1973-08-31
osteo- articular bone grafts. Clin. Ortho., 87: 156, 1972. 8. Tuli, S. M.: Bridging of bone defects by massive bone grafts in tumorous conditions. Clin...fashion in its proximal one-third to "prevent distractic ,n of the fragments. The fiber metal segment was then placed in the appropriate defect and the...defect slightly oversized and also osteotomizing the fibula to delete any possible distracting forces or angulating forces. The only complication in
Iskandrian, A S; Powers, J; Cave, V; Wasserleben, V; Cassell, D; Heo, J
1995-01-01
This study examined the ability of dynamic 123I-labeled iodophenylpentadecanoic acid (IPPA) imaging to detect myocardial viability in patients with left ventricular (LV) dysfunction caused by coronary artery disease. Serial 180-degree single-photon emission computed tomographic (SPECT) images (five sets, 8 minutes each) were obtained starting 4 minutes after injection of 2 to 6 mCi 123I at rest in 21 patients with LV dysfunction (ejection fraction [EF] 34% +/- 11%). The segmental uptake was compared with that of rest-redistribution 201Tl images (20 segments/study). The number of perfusion defects (reversible and fixed) was similar by IPPA and thallium (11 +/- 5 vs 10 +/- 5 segments/patient; difference not significant). There was agreement between IPPA and thallium for presence or absence (kappa = 0.78 +/- 0.03) and nature (reversible, mild fixed, or severe fixed) of perfusion defects (kappa = 0.54 +/- 0.04). However, there were more reversible IPPA defects than reversible thallium defects (7 +/- 4 vs 3 +/- 4 segments/patient; p = 0.001). In 14 patients the EF (by gated pool imaging) improved after coronary revascularization from 33% +/- 11% to 39% +/- 12% (p = 0.002). The number of reversible IPPA defects was greater in the seven patients who had improvement in EF than in the patients without such improvement (10 +/- 4 vs 5 +/- 4 segments/patient; p = 0.075). 123I-labeled IPPA SPECT imaging is a promising new technique for assessment of viability. Reversible defects predict recovery of LV dysfunction after coronary revascularization.
NASA Astrophysics Data System (ADS)
Wan, Weibing; Shi, Pengfei; Li, Shuguang
2009-10-01
Given the potential demonstrated by research into bone-tissue engineering, the use of medical image data for the rapid prototyping (RP) of scaffolds is a subject worthy of research. Computer-aided design and manufacture and medical imaging have created new possibilities for RP. Accurate and efficient design and fabrication of anatomic models is critical to these applications. We explore the application of RP computational methods to the repair of a pediatric skull defect. The focus of this study is the segmentation of the defect region seen in computerized tomography (CT) slice images of this patient's skull and the three-dimensional (3-D) surface rendering of the patient's CT-scan data. We see if our segmentation and surface rendering software can improve the generation of an implant model to fill a skull defect.
Lateral ankle instability in high-demand athletes: reconstruction with fibular periosteal flap.
Benazzo, Francesco; Zanon, Giacomo; Marullo, Matteo; Rossi, Stefano Marco Paolo
2013-09-01
Fibular periosteal flaps have been used to address chronic lateral ankle instability, but there are no studies in the literature reporting functional outcomes after this particular procedure in high-demand athletes. We postulated that for chronic instability, nonanatomical reconstruction of the lateral ankle ligament with a fibular periosteal flap will return high-demand athletes to their previous levels of activity. Forty patients who had grade III ankle sprain and experienced no success after a course of supervised conservative management lasting at least six months and who had a preinjury Tegner score of ≥ 6 underwent a lateral compartment reconstruction with a fibular periosteal flap. Each patient was given the Tegner and Karlsson questionnaire and was evaluated by the Zwipp method, Foot and Ankle Outcome Score (FAOS) and the American Orthopaedic Foot and Ankle Society (AOFAS) score at the six-month, one, two and three-year time points. Range of motion (ROM) of the affected ankle was assessed, and stress X-rays were performed. Mean patient age was 24.5 (range17-30) years, and no patient was lost to follow-up. Mean follow-up was 36 (minimum 18) months, mean Tegner scores at the one, two and three-year time points were 8.8, 8.9 and 8.9, respectively, and mean Karlsson scores were 93 ± 5.2, 95 ± 3.1 and 94.9, respectively. AOFAS and FAOS scores improved from a mean of 69.4 and 71.4, respectively, in the preoperative group to a mean of 97.2 and 94.4, respectively, at the last follow-up. The ROM was equal to the contralateral ankle in all but two patients at the two-year follow-up. No major complications were found. Nonanatomical ligament reconstruction with a fibular periosteal flap for chronic lateral ankle instability was effective in returning high-demand athletes to their preinjury functional levels.
The metatarsosesamoid joint: an in vitro 3D quantitative assessment.
Jamal, Bilal; Pillai, Anand; Fogg, Quentin; Kumar, Senthil
2015-03-01
The anatomy of the first metatarsophalangeal (MTP) joint, particularly the metatarsosesamoid articulation, remains poorly understood. Our goal was to quantitatively define the excursion of the sesamoids. Seven cadavers were dissected to assess the articulating surfaces throughout a normal range of motion. The dissections were digitally reconstructed in various positions using a MicroScribe. For first MTP joint, excursion averaged 14.7mm for the tibial sesamoid in the sagittal plane and 7.5mm for the fibular sesamoid. The sesamoids also moved medially to laterally when the joint was dorsiflexed. For the maximally dorsiflexed joint, excursion averaged 2.8mm for the tibial sesamoid and 3.5mm for the fibular sesamoid. Hallucal sesamoids appear to have differential tracking: the tibial sesamoid has greater longitudinal excursion; the fibular sesamoid has greater lateral excursion. The anatomical data will interest those involved with the design of an effective hallux arthroplasty. Copyright © 2014 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
Optimizing Soft Tissue Management and Spacer Design in Segmental Bone Defects
2016-12-01
proximal and distal bone segments. 3. Debride 10 grams of tibialis anterior and gastrocnemius muscles. 4. Place an interlocking intramedullary nail ...using a custom spacer to maintain 5-cm defect length. 5. Place a pre-molded 5 cm long x 2 cm diameter PMMA spacer around the nail in the defect. 6...tibia. 3. Open the IM surrounding the PMMA spacer using a “bomb bay door opening”. 4. Remove the spacer without damaging the membrane or nail . 5
Zhang, C; Wang, J; Feng, H; Lu, B; Song, Z; Zhang, X
2001-03-05
A porous ceramic material [hydroxyapatitetricalcium phosphate (HA-TCP)] was implanted in the femora of 30 dogs to investigate the possibility of using this material to repair segmental bone defects. A bone segment, 1.5 cm in length, was removed from the diaphysis of one femur in each dog to create the defect. Cylinders of corresponding size were inserted into the defects. The animals were divided into three groups with recovery times of 2 months, 4 months, and 6 months, respectively. The implants were harvested and subjected to biomechanic tests (bending strength) and X-ray diffraction analysis. The bending strengths of the implant construct increased gradually over time postoperatively. The values of strength for the three different time groups had significant variations (p < 0.05). The X-ray diffraction analysis indicated that the peaks of the TCP included in the cylinders decreased in intensity after implantation and tended to be similar to those of natural bone by 6 months after operation. Conversely, the peaks for the HA had fewer changes compared with preimplantation values. Based on the results of this experiment it was concluded that the porous HA-TCP ceramic cylinders have potential for repair of segmental bone defects if assisted by adequate stabilizing fixtures during the early postoperative period.
Xing, Junchao; Jin, Huiyong; Hou, Tianyong; Chang, Zhengqi; Luo, Fei; Wang, Pinpin; Li, Zhiqiang; Xie, Zhao; Xu, Jianzhong
2014-12-01
To understand the cellular mechanism underlying bone defect healing in the context of tissue engineering, a reliable, reproducible, and standardized load-bearing large segmental bone defect model in small animals is indispensable. The aim of this study was to establish and evaluate a bilateral femoral defect model in mice. Donor mouse bone marrow mesenchymal stem cells (mBMSCs) were obtained from six mice (FVB/N) and incorporated into partially demineralized bone matrix scaffolds to construct tissue-engineered bones. In total, 36 GFP(+) mice were used for modeling. Titanium fixation plates with locking steel wires were attached to the femurs for stabilization, and 2-mm-long segmental bone defects were created in the bilateral femoral midshafts. The defects in the left and right femurs were transplanted with tissue-engineered bones and control scaffolds, respectively. The healing process was monitored by x-ray radiography, microcomputed tomography, and histology. The capacity of the transplanted mBMSCs to recruit host CD31(+) cells was investigated by immunofluorescence and real-time polymerase chain reaction. Postoperatively, no complication was observed, except that two mice died of unknown causes. Stable fixation of femurs and implants with full load bearing was achieved in all animals. The process of bone defect repair was significantly accelerated due to the introduction of mBMSCs. Moreover, the transplanted mBMSCs attracted more host CD31(+) endothelial progenitors into the grafts. The present study established a feasible, reproducible, and clinically relevant bilateral femoral large segmental bone defect mouse model. This model is potentially suitable for basic research in the field of bone tissue engineering. Copyright © 2014 Elsevier Inc. All rights reserved.
Correlation between spectral-domain OCT findings and visual acuity in X-linked retinoschisis.
Yang, Hyun Seung; Lee, Jung Bok; Yoon, Young Hee; Lee, Joo Yong
2014-05-08
To investigate the tomographic characteristics of the outer retina and choroid and their relationship with visual acuity in X-linked juvenile retinoschisis (XLRS) patients using spectral-domain optical coherence tomography (SD-OCT). In this retrospective, observational, case-control study, we analyzed 20 eyes of 10 patients with XLRS using SD-OCT. The clinical and tomographic features of the outer retina, including the external limiting membrane (ELM), inner segment/outer segment (IS/OS) junction, cone cell outer segment tips (COST) line, photoreceptor outer segment (PROS) length, and choroid, were evaluated. As controls, 40 age-, sex-, and refraction-matched healthy eyes (1:2 matched) were randomly selected and imaged in parallel. The most prevalent area of abnormality in the outer retina layer of our patients was the outer plexiform layer (OPL; 60% of all affected eyes) and COST line (75% of all affected eyes). On average, the subfoveal choroid and PROS lengths were 35 μm thicker and 19 μm thinner, respectively, in XLRS patients (P = 0.084 and P < 0.001, respectively). A dominant IS/OS junction, COST line defects, and PROS length were related to patient best-corrected visual acuity (BCVA; P = 0.029, P = 0.001, and P < 0.001, respectively) by univariate analysis. Cone cell outer segment tips line defect and PROS length were the only factors related to BCVA in multivariate analysis (P = 0.028 and 0.003, respectively). Outer plexiform layer and photoreceptor microstructure defects are frequent in XLRS patients. Cone cell outer segment tips line defects and shortened PROS lengths as well as other photoreceptor microstructure defects may be closely related to poor vision in XLRS.
Li, Zonghuan; Yu, Aixi; Qi, Baiwen; Pan, Zhenyu; Ding, Junhui
2017-08-01
The aim of this report was to present the use of flow-through free fibula osteocutaneous flap for the repair of complex tibial bone, soft tissue, and main artery segmental defects. Five patients with bone, soft tissue, and segmental anterior tibial artery defects were included. The lengths of injured tibial bones ranged from 4 to 7 cm. The sizes of impaired soft tissues were between 9 × 4 and 15 × 6 cm. The lengths of defect of anterior tibial artery segments ranged from 6 to 10 cm. Two patients had distal limb perfusion problems. Flow-through free fibula osteocutaneous flap was performed for all 5 patients. Patients were followed for 12 to 18 months. All wounds healed after 1-stage operation, and all flow-through flaps survived. The distal perfusion after vascular repair was normal in all patients. Superficial necrosis of flap edge was noted in 1 case. After the local debridement and partial thickness skin graft, the flap healed uneventfully, and the surgical operation did not increase injury to the donor site. Satisfactory bone union was achieved in all patients in 2 to 4 months postoperation. Enlargement of fibula graft was observed during follow-up from 12 to 18 months. The functions of adjacent joints were recovered, and all patients were able to walk normally. Flow-through free fibula osteocutaneous flap was shown to be an effective and efficient technique for repairing composite tibial bone, soft tissue, and main artery segmental defects. This 1-stage operation should be useful in clinical practice for the treatment of complex bone, soft tissue, and vessel defects.
NASA Astrophysics Data System (ADS)
Huang, Yishuo; Chiang, Chih-Hung; Hsu, Keng-Tsang
2018-03-01
Defects presented on the facades of a building do have profound impacts on extending the life cycle of the building. How to identify the defects is a crucial issue; destructive and non-destructive methods are usually employed to identify the defects presented on a building. Destructive methods always cause the permanent damages for the examined objects; on the other hand, non-destructive testing (NDT) methods have been widely applied to detect those defects presented on exterior layers of a building. However, NDT methods cannot provide efficient and reliable information for identifying the defects because of the huge examination areas. Infrared thermography is often applied to quantitative energy performance measurements for building envelopes. Defects on the exterior layer of buildings may be caused by several factors: ventilation losses, conduction losses, thermal bridging, defective services, moisture condensation, moisture ingress, and structure defects. Analyzing the collected thermal images can be quite difficult when the spatial variations of surface temperature are small. In this paper the authors employ image segmentation to cluster those pixels with similar surface temperatures such that the processed thermal images can be composed of limited groups. The surface temperature distribution in each segmented group is homogenous. In doing so, the regional boundaries of the segmented regions can be identified and extracted. A terrestrial laser scanner (TLS) is widely used to collect the point clouds of a building, and those point clouds are applied to reconstruct the 3D model of the building. A mapping model is constructed such that the segmented thermal images can be projected onto the 2D image of the specified 3D building. In this paper, the administrative building in Chaoyang University campus is used as an example. The experimental results not only provide the defect information but also offer their corresponding spatial locations in the 3D model.
Pietsch, Arnold P; Raith, Stefan; Ode, Jan-Eric; Teichmann, Jan; Lethaus, Bernd; Möhlhenrich, Stephan C; Hölzle, Frank; Duda, Georg N; Steiner, Timm
2016-06-01
The goal of this study was to determine a combination of screw and transplantation type that offers optimal primary stability for reconstructive surgery. Fibular, iliac crest, and scapular transplants were tested along with artificial bone substrate. Six different kinds of bone screws (Medartis(©)) were compared, each type utilized with one of six specimens from human transplants (n = 6). Controlled screw-in-tests were performed and the required torque was protocolled. Subsequently, pull-out-tests were executed to determine the retention forces. The artificial bone substitute material showed significantly higher retention forces than real bone samples. The self-drilling screws achieved the significantly highest retention values in the synthetic bone substitute material. Cancellous screws achieved the highest retention in the fibular transplants, while self-drilling and cancellous screws demonstrated better retention than cortical screws in the iliac crest. In the scapular graft, no significant differences were found between the screw types. In comparison to the human transplant types, the cortical screws showed the significantly highest values in the fibula and the lowest values in the iliac crest. The best retention was found in the combination of cancellous screws with fibular graft (514.8 N + -252.3 N). For the flat bones (i.e., scapular and illiac crest) we recommend the cancellous screws. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Yang, Yun-Fa; Wang, Jian-Wei; Huang, Pin; Xu, Zhong-He
2016-08-17
Giant cell tumors (GCTs) located in the distal radius are likely to recur, and the treatment of such recurrent tumors is very difficult. Here, we report our clinical experience in distal radius reconstruction with vascularized proximal fibular autografts after en-bloc excision of the entire distal radius in 17 patients with recurrent GCT (RGCT) of the distal radius. All 17 patients with RGCT in distal radius underwent plain radiography and/or magnetic resonance imaging (MRI) of the distal radius as the initial evaluation after hospitalization. Then the distal radius were replaced by vascularized proximal fibular autografts after en-bloc RGCT resection. We assessed all patients by using clinical examinations, plain radiography of the wrist and chest, and Mayo wrist scores in the follow-ups. After an average follow-up of 4.3 years (range: 1.5-10.0 years), no lung metastasis or local recurrence was detected in any of the 17 patients. In total, 14 patients had excellent or good functional wrist scores, 16 were pain free or had occasional pain, and 15 patients returned to work. The mean range of motion of the wrist was 101° (flexion-extension), and the mean grip strength was 77.2 % of the contralateral normal hand. En-bloc excision of the entire distal radius and distal radius reconstruction with a vascularized proximal fibular autograft can effectively achieve local tumor control and preserve wrist function in patients with RGCT of the distal radius.
Ahn, Seong Joon; Ahn, Jeeyun; Woo, Se Joon; Park, Kyu Hyung
2014-01-01
To compare the postoperative photoreceptor status and visual outcome after epiretinal membrane removal with or without additional internal limiting membrane (ILM) peeling. Medical records of 40 eyes from 37 patients undergoing epiretinal membrane removal with residual ILM peeling (additional ILM peeling group) and 69 eyes from 65 patients undergoing epiretinal membrane removal without additional ILM peeling (no additional peeling group) were reviewed. The length of defects in cone outer segment tips, inner segment/outer segment junction, and external limiting membrane line were measured using spectral domain optical coherence tomography images of the fovea before and at 1, 3, 6, and 12 months after the surgery. Cone outer segment tips and inner segment/outer segment junction line defects were most severe at postoperative 1 month and gradually restored at 12 months postoperatively. The cone outer segment tips line defect in the additional ILM peeling group was significantly greater than that in the no additional peeling group at postoperative 1 month (P = 0.006), and best-corrected visual acuity was significantly worse in the former group at the same month (P = 0.001). There was no significant difference in the defect size and best-corrected visual acuity at subsequent visits and recurrence rates between the two groups. Patients who received epiretinal membrane surgery without additional ILM peeling showed better visual and anatomical outcome than those with additional ILM peeling at postoperative 1 month. However, surgical outcomes were comparable between the two groups, thereafter. In terms of visual outcome and photoreceptor integrity, additional ILM peeling may not be an essential procedure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Metaizeau, J.P.; Olive, D.; Bey, P.
1984-04-01
In conservative treatment of malignant bone tumors, assessment of the local condition is difficult. The radiological changes seen in the irradiated tumor and the frequent occurrence of pathological fractures at this site may give rise to the fear that the tumor has relapsed. Resection of the whole of the involved bone is the best way to assure adequate local control but the extent of the bone defect and the bad local conditions secondary to irradiation make reconstruction hazardous. In two patients (one with Ewing's sarcoma of the femur and one with osteogenic sarcoma of the humerus) the authors used amore » free, vascularized fibular graft for the reconstruction having obtained consolidation of the limb after resection of the irradiated tumor, with preservation of its function. The encouraging results obtained have suggested a conservative attitude as primary treatment of specific malignant bone tumors.« less
Use of vascularised free fibula in limb reconstruction (for non-malignant defects).
Hameed, Shahid; Ehtesham-ul-haq, Rana Hassan Javaid; Ahmed, Rao Saood; Majid, Abdul; Waqas, Muhammad; Aslam, Ayesha; Yusuf, Omamah; Butt, Ahsin Masood; Ali, Ghazanfar
2013-12-01
The case series was conducted at the Department of Plastic Surgery, Combined Military Hospital, Rawalpindi, from June 2009 to May 2011, and comprised 19 patients in whom free fibula flap was performed for upper and lower limb reconstruction, using SPSS 16. Results showed that flap survival was 100%. One (5.2%) flap was re-explored for venous congestion and was salvaged. One (5.2%) patient of congenital pseudoarthrosis of tibia had a fracture of the fibula and was treated with external fixation. Average follow up was 8 months. Mean union time and full weight-bearing was 6.5 +/- 1.34 months (range 3-8 months) and 9 months, respectively. No recurrence of pseudoathrosis was observed until the last follow up, with only a 1.5 cm length discrepancy in one patient. The results proved that a microvascular free fibular flap heals rapidly, causes early functional recovery and it can be raised as an osteocutaneous flap.
7 CFR 51.1837 - Classification of defects.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Definitions § 51.1837 Classification of defects. Table I Factor Damage Serious damage Very serious damage... segments more than 1/8 inch (3.2 mm) at stem end, or the equivalent of this amount, by volume, when occurring in other portions of the fruit Affecting all segments more than 1/4 inch (6.4 mm) at stem end, or...
7 CFR 51.1837 - Classification of defects.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Definitions § 51.1837 Classification of defects. Table I Factor Damage Serious damage Very serious damage... segments more than 1/8 inch (3.2 mm) at stem end, or the equivalent of this amount, by volume, when occurring in other portions of the fruit Affecting all segments more than 1/4 inch (6.4 mm) at stem end, or...
Tool Measures Depths of Defects on a Case Tang Joint
NASA Technical Reports Server (NTRS)
Ream, M. Bryan; Montgomery, Ronald B.; Mecham, Brent A.; Keirstead, Bums W.
2005-01-01
A special-purpose tool has been developed for measuring the depths of defects on an O-ring seal surface. The surface lies in a specially shaped ringlike fitting, called a capture feature tang, located on an end of a cylindrical segment of a case that contains a solid-fuel booster rocket motor for launching a space shuttle. The capture feature tang is a part of a tang-and-clevis, O-ring joint between the case segment and a similar, adjacent cylindrical case segment. When the segments are joined, the tang makes an interference fit with the clevis and squeezes the O-ring at the side of the gap.
Naruse, H; Yoshimura, N; Yamamoto, J; Morita, M; Fukutake, N; Ohyanagi, M; Iwasaki, T; Fukuchi, M
1994-01-01
Myocardial imaging using beta-methyl-p-[123I]-iodophenylpentadecanoic acid (BMIPP) of 15 patients with acute myocardial infarction was performed to assess "fill-in" and "washout" defects in the delayed myocardial image. The initial and delayed images were evaluated by a visual and quantitative washout rate method. Visual judgement found 8/180 (4%) segments showed "fill-in" defects, and 24/180 segments (13%) showed "washout" defects. There was no relationship between days from onset to the study and the frequency of fill-in and washout defects. The mean washout rate in the segments with "fill-in" defects was 9.0 +/- 16.6%, and that of "washout" defects was 24.9 +/- 18.1% which was significantly higher than in controls (8.7 +/- 15.4%, p < 0.05). There was no correlation between mean washout rate and total blood lipids, total cholesterol, triglyceride and HDL-cholesterol. Therefore, neither time from onset nor blood lipids level was related to changes from the initial image to the delayed image. These changes may be due to relative (false) findings due to changes in circumference, and may be based on myocardial characteristics after myocardial infarction and/or reperfusion.
NASA Astrophysics Data System (ADS)
Sun, Qianlai; Wang, Yin; Sun, Zhiyi
2018-05-01
For most surface defect detection methods based on image processing, image segmentation is a prerequisite for determining and locating the defect. In our previous work, a method based on singular value decomposition (SVD) was used to determine and approximately locate surface defects on steel strips without image segmentation. For the SVD-based method, the image to be inspected was projected onto its first left and right singular vectors respectively. If there were defects in the image, there would be sharp changes in the projections. Then the defects may be determined and located according sharp changes in the projections of each image to be inspected. This method was simple and practical but the SVD should be performed for each image to be inspected. Owing to the high time complexity of SVD itself, it did not have a significant advantage in terms of time consumption over image segmentation-based methods. Here, we present an improved SVD-based method. In the improved method, a defect-free image is considered as the reference image which is acquired under the same environment as the image to be inspected. The singular vectors of each image to be inspected are replaced by the singular vectors of the reference image, and SVD is performed only once for the reference image off-line before detecting of the defects, thus greatly reducing the time required. The improved method is more conducive to real-time defect detection. Experimental results confirm its validity.
Pitarokoili, Kalliopi; Kronlage, Moritz; Bäumer, Philip; Schwarz, Daniel; Gold, Ralf; Bendszus, Martin; Yoon, Min-Suk
2018-01-01
Background: We present a clinical, electrophysiological, sonographical and magnetic resonance neurography (MRN) study examining the complementary role of two neuroimaging methods of the peripheral nervous system for patients with chronic inflammatory demyelinating polyneuropathy (CIDP). Furthermore, we explore the significance of cross-sectional area (CSA) increase through correlations with MRN markers of nerve integrity. Methods: A total of 108 nerve segments on the median, ulnar, radial, tibial and fibular nerve, as well as the lumbar and cervical plexus of 18 CIDP patients were examined with high-resonance nerve ultrasound (HRUS) and MRN additionally to the nerve conduction studies. Results: We observed a fair degree of correlation of the CSA values for all nerves/nerve segments between the two methods, with a low random error in Bland–Altman analysis (bias = HRUS-CSA − MRN-CSA, −0.61 to −3.26 mm). CSA in HRUS correlated with the nerve T2-weighted (nT2) signal increase as well as with diffusion tensor imaging parameters such as fractional anisotropy, a marker of microstructural integrity. HRUS-CSA of the interscalene brachial plexus correlated significantly with the MRN-CSA and nT2 signal of the L5 and S1 roots of the lumbar plexus. Conclusions: HRUS allows for reliable CSA imaging of all peripheral nerves and the cervical plexus, and CSA correlates with markers of nerve integrity. Imaging of proximal segments as well as the estimation of nerve integrity require MRN as a complementary method. PMID:29552093
Krishnan, Kartik G; Müller, Adolf
2002-04-01
Reconstruction of the cervical spine using free vascularized bone flaps has been described in the literature. The reports involve either one level or, when multiple levels, they describe en bloc resection and reconstruction. Stabilization of different levels with a preserved intermediate segment with a single vascularized flap has not been described. We report on the case of a 55-year-old man, who had been operated several times using conventional techniques for cervical myelopathy and instability, who presented to us with severe neck pain. Diagnostic procedures showed pseudarthrosis of C3/4 and stress-overload of the C3/4 and C5/6 segments. The C4/5 fusion was adequately rigid, but avascular. We performed anterior cervical fusion at the C3/4 and C5/6 levels with a vascularized fibula flap modified as a double island. The rigidly fused C4/5 block was preserved and vascularized with the periosteum bridging the two fibular islands. The method and technique are described in detail. Fusion was adequate. Donor site morbidity was minimal and temporary. The patient is symptom free to date (25 months). The suggested method provides the possibility of vertebral fusion at different levels using a single vascularized flap. The indications for this procedure are (1) repeated failure of conventional methods, (2) established poor bone healing and bone non-union with avascular grafts and (3) a well-fused or preserved intermediate segment. The relevant literature is reviewed.
Color image segmentation to detect defects on fresh ham
NASA Astrophysics Data System (ADS)
Marty-Mahe, Pascale; Loisel, Philippe; Brossard, Didier
2003-04-01
We present in this paper the color segmentation methods that were used to detect appearance defects on 3 dimensional shape of fresh ham. The use of color histograms turned out to be an efficient solution to characterize the healthy skin, but a special care must be taken to choose the color components because of the 3 dimensional shape of ham.
[The monorail system--bone segment transport over unreamed interlocking nails].
Oedekoven, G; Jansen, D; Raschke, M; Claudi, B F
1996-11-01
A treatment protocol is demonstrated, consisting of an osteotomy, either proximal or distal, of the bone defect with subsequent segmental transport via an anteromedially (tibia) or laterally (femur) mounted AO external fixation over an unreamed interlocking nail (monorail system). Twenty patients were treated by this method with indications as follows: 13 had a segmental bone defect of the tibia, 3 of the femur. Three patients showed post-traumatic and postinfectious leg-length discrepancies and one was treated for hypertrophic non-union of the femur. Defect distance varied between 5 and 18.5 cm and average time for transport was 19,42 days/ cm for the tibial shaft, 15,93 days/cm for the femur. Two patients developed deep infection, which required change of treatment, removing the monorail system and application of an Ilizarov apparatus. Despite complications using the monorail system, all patients healed and no amputations were required. The monorail system can be used as an alternative to the Ilizarov method under certain criteria of patient selection; these criteria are shown by an algorithm for segmental bone defects without infection, respecting the soft-tissue status with or without neurovascular compromise.
Use of Paley Classification and SUPERankle Procedure in the Management of Fibular Hemimelia.
Kulkarni, Ruta M; Arora, Nitish; Saxena, Sagar; Kulkarni, Sujay M; Saini, Yadwinder; Negandhi, Rajiv
2017-05-26
Fibular hemimelia is the most common deficiency involving the long bones. Paley classification is based on the ankle joint morphology, identifies the basic pathology, and helps in planning the surgical management. Reconstruction surgery encompasses foot deformity correction and limb length equalization. The SUPERankle procedure is a combination of bone and soft tissue procedures that stabilizes the foot and addresses all deformities. We retrospectively reviewed 29 consecutive patients (29 limb segments), surgically treated between December 2000 and December 2014. Among the 29 patients, 27 were treated with reconstructive procedures. Type 1 (8 patients) cases were treated with only limb lengthening, and correction of tibial deformities. Type 2 (7 patients) cases were treated by distal tibial medial hemiepiphysiodesis or supramalleolar varus osteotomy. In type 3 (10 patients) cases, the foot deformity was corrected using the SUPERankle procedure. Type 4 (2 patients) cases were treated with supramalleolar osteotomy along with posteromedial release and lateral column shortening. In a second stage, limb lengthening was performed, using the Ilizarov technique. In the remaining 2 patients (type 3A and type 3C), amputation was performed using Syme technique as a first choice of treatment. The results were evaluated using Association for the Study and Application of Methods of Ilizarov scoring. Excellent results were obtained in 15 of 27 (55%) patients. Six (22%) patients had good results, 4 (14.8%) had fair results, and 2 (7%) had poor results. Mean limb length discrepancy at initial presentation was 3.55 cm (range: 2 to 5.5 cm) which significantly improved to 1.01 cm (range: 0 to 3 cm) after treatment (P=0.015). Our results and a review of the literature clearly suggest that limb reconstruction according to Paley classification, is an excellent option in the management of fibular hemimelia. Our 2-staged procedure (SUPERankle procedure followed by limb lengthening) helps in reducing the complications of limb lengthening and incidence of ankle stiffness. Performing the first surgery at an earlier age (below 5 y) plays a significant role in preventing recurrent foot deformities. Level IV.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0/.
Management of fibular hemimelia using the Ilizarov method at Siriraj Hospital in Thailand.
Unprasert, Prangthong; Kaewpornsawan, Kamolporn; Chotigavanichaya, Chatupon; Eamsobhana, Perajit
2014-09-01
Fibular hemimelia is one of the most common congenital longitudinal bone deficiencies. Previous treatment protocols called for amputation of the deficient limb; while others made attempts to save the limb. The objective of treatment is to restore function and achieve patient satisfaction. The authors evaluated the outcomes of the Ilizarov technique for the treatment of leg-length discrepancy and bone associated deformities in patients with fibular hemimelia. The present study also evaluated and assessed complications, knee and ankle function, and patient satisfaction with the treatment. Nine patients with fibular hemimelia who underwent tibial lengthening using the Ilizarov method were reviewed in the present study. Initial condition data, including age, gender type offibular hemimelia, initial limb-length discrepancy, predicted limb-length discrepancy, and the data were collected and analyzed. Activity level, patient satisfaction, complications, and residual leg-length discrepancy were assessed at the end of treatment. According to Achterman and Kalamchi classification, there were 4 patients with Type IA, 3 patients with Type IB, and 2 patients with Type II. In Type IA, the affected leg-length discrepancy and mean age at the initial treatment were 3.25 cm and 7.75 years, respectively. In type IB, the affected leg-length discrepancy and mean age at the initial treatment were 5.83 cm and 4.3 years, respectively. In Type II, the affected leg-length discrepancy and mean age at the initial treatment were 5.5 cm and 5 years, respectively. The mean follow-up was 5 years (range: 7-10). The mean lengthening was 7.52 cm (range: 4-13). The lengthening index was 1.28 mo/cm. The mean residual leg-length discrepancy was 0.94 cm. There was ankle joint stiffness and mild equinous foot in type II cases, but patients could walk well without gait aid. No patients were experiencing pain by the end of treatment. All patients expressed satisfaction with this technique. The Ilizarov technique for bone lengthening of the tibia has shown satisfactory results in the treatment of all types of congenital fibular hemimelia and should be considered an attractive alternative to amputation, as measureable functional improvement can be expected.
Ashman, B D; Kong, C; Wing, K J; Penner, M J; Bugler, K E; White, T O; Younger, A S E
2016-09-01
Patients with diabetes are at increased risk of wound complications after open reduction and internal fixation of unstable ankle fractures. A fibular nail avoids large surgical incisions and allows anatomical reduction of the mortise. We retrospectively reviewed the results of fluoroscopy-guided reduction and percutaneous fibular nail fixation for unstable Weber type B or C fractures in 24 adult patients with type 1 or type 2 diabetes. The re-operation rate for wound dehiscence or other indications such as amputation, mortality and functional outcomes was determined. Two patients developed lateral side wound infection, one of whom underwent wound debridement. Three other patients required re-operation for removal of symptomatic hardware. No patient required a below-knee amputation. Six patients died during the study period for unrelated reasons. At a median follow-up of 12 months (7 to 38) the mean Short Form-36 Mental Component Score and Physical Component Score were 53.2 (95% confidence intervals (CI) 48.1 to 58.4) and 39.3 (95% CI 32.1 to 46.4), respectively. The mean Visual Analogue Score for pain was 3.1 (95% 1.4 to 4.9). The mean Ankle Osteoarthritis Scale total score was 32.9 (95% CI 16.0 to 49.7). Fluoroscopy-guided reduction and fibular nail fixation of unstable ankle fractures in patients with diabetes was associated with a low incidence of wound and overall complications, while providing effective surgical fixation. Cite this article: Bone Joint J 2016;98-B:1197-1201. ©2016 The British Editorial Society of Bone & Joint Surgery.
Imaging in syndesmotic injury: a systematic literature review.
Krähenbühl, Nicola; Weinberg, Maxwell W; Davidson, Nathan P; Mills, Megan K; Hintermann, Beat; Saltzman, Charles L; Barg, Alexej
2018-05-01
To give a systematic overview of current diagnostic imaging options for assessment of the distal tibio-fibular syndesmosis. A systematic literature search across the following sources was performed: PubMed, ScienceDirect, Google Scholar, and SpringerLink. Forty-two articles were included and subdivided into three groups: group one consists of studies using conventional radiographs (22 articles), group two includes studies using computed tomography (CT) scans (15 articles), and group three comprises studies using magnet resonance imaging (MRI, 9 articles).The following data were extracted: imaging modality, measurement method, number of participants and ankles included, average age of participants, sensitivity, specificity, and accuracy of the measurement technique. The Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool was used to assess the methodological quality. The three most common techniques used for assessment of the syndesmosis in conventional radiographs are the tibio-fibular clear space (TFCS), the tibio-fibular overlap (TFO), and the medial clear space (MCS). Regarding CT scans, the tibio-fibular width (axial images) was most commonly used. Most of the MRI studies used direct assessment of syndesmotic integrity. Overall, the included studies show low probability of bias and are applicable in daily practice. Conventional radiographs cannot predict syndesmotic injuries reliably. CT scans outperform plain radiographs in detecting syndesmotic mal-reduction. Additionally, the syndesmotic interval can be assessed in greater detail by CT. MRI measurements achieve a sensitivity and specificity of nearly 100%; however, correlating MRI findings with patients' complaints is difficult, and utility with subtle syndesmotic instability needs further investigation. Overall, the methodological quality of these studies was satisfactory.
Anatomic mapping for surgical reconstruction of the proximal tibiofibular ligaments.
See, Aaron; Bear, Russell R; Owens, Brett D
2013-01-01
Injury to the proximal tibiofibular joint is uncommon. Previous studies regarding the anatomy of this region have predominantly focused on joint orientation. As radiographic technology has advanced, later studies have attempted to evaluate the capsular anatomy. However, no reports specifically map the ligaments to this joint. The objectives of the current study were to define specific ligamentous structures that provide stability to the proximal tibiofibular joint, describe easily identifiable and reproducible surgical landmarks to aid in surgical reconstruction, and add to the understanding of the posterolateral structures of the knee previously described by other authors. The proximal tibiofibular joint ligaments were identified in 10 fresh-frozen cadaveric specimens. Average ligament length, width, and thickness and area of the footprints of the tibial and fibular attachments were measured. Distances from the ligament footprints to known anatomic landmarks (eg, Gerdy's tubercle, tibial articular surface, and fibular styloid) were also measured. The anterior ligament tibial attachment was a mean of 15.6 mm lateral and posterior to Gerdy's tubercle and 17.3 mm anterior and inferior from the fibular styloid. Posterior ligament tibial insertion was a mean of 15.7 mm inferior to the tibial articular surface on the tibial side and 14.2 mm medial and slightly inferior from the fibular styloid. Definable ligaments provide stability to the proximal tibiofibular joint and can be reconstructed in an anatomic fashion using the landmarks and parameters described. This information allows for an anatomic reconstruction of the proximal tibiofibular joint, which should provide patients with better outcomes and fewer postoperative sequelae. Copyright 2013, SLACK Incorporated.
Amr, Sherif M; El-Mofty, Aly O; Amin, Sherif N
2002-01-01
The potentialities, limitations, and technical pitfalls of the vascularized fibular grafting in infected nonunions of the tibia are outlined on the basis of 14 patients approached anteriorly or posteriorly. An infected nonunion of the tibia together with a large exposed area over the shin of the tibia is better approached anteriorly. The anastomosis is placed in an end-to-end or end-to-side fashion onto the anterior tibial vessels. To locate the site of the nonunion, the tibialis anterior muscle should be retracted laterally and the proximal and distal ends of the site of the nonunion debrided up to healthy bleeding bone. All the scarred skin over the anterior tibia should be excised, because it becomes devitalized as a result of the exposure. To cover the exposed area, the fibula has to be harvested with a large skin paddle, incorporating the first septocutaneous branch originating from the peroneal vessels before they gain the upper end of the flexor hallucis longus muscle. A disadvantage of harvesting the free fibula together with a skin paddle is that its pedicle is short. The skin paddle lies at the antimesenteric border of the graft, the site of incising and stripping the periosteum. In addition, it has to be sutured to the skin at the recipient site, so the soft tissues (together with the peroneal vessels), cannot be stripped off the graft to prolong its pedicle. Vein grafts should be resorted to, if the pedicle does not reach a healthy segment of the anterior tibial vessels. Defects with limited exposed areas of skin, especially in questionable patency of the vessels of the leg, require primarily a fibula with a long pedicle that could easily reach the popliteal vessels and are thus better approached posteriorly. In this approach, the site of the nonunion is exposed medial to the flexor digitorum muscle and the proximal and distal ends of the site of the nonunion debrided up to healthy bleeding bone. No attempt should be made to strip the scarred skin off the anterior aspect of the bone lest it should become devitalized. Any exposed bone on the anterior aspect should be left to granulate alone. This occurs readily when stability has been regained at the fracture site after transfer of the free fibula. The popliteal and posterior tibial vessels are exposed, and the microvascular anastomosis placed in an end-to-side fashion onto either of them, depending on the length of the pedicle and the condition of the vessels themselves. To obtain the maximal length of the pedicle of the graft, the proximal osteotomy is placed at the neck of the fibula after decompressing the peroneal nerve. The distal osteotomy is placed as distally as possible. After detaching the fibula from the donor site, the proximal part of the graft is stripped subperiosteally, osteotomized, and discarded. Thus, a relatively long pedicle could be obtained. To facilitate subperiosteal stripping, the free fibula is harvested without a skin paddle. In this way, the use of a vein graft could be avoided. Patients presenting with infected nonunions of the tibia with extensive scarring of the lower extremity, excessively large areas of skin loss, and with questionable patency of the anterior and posterior tibial vessels are not suitable candidates for the free vascularized fibular graft. Although a vein graft could be used between the recipient popliteal and the donor peroneal vessels, its use decreases flow to the graft considerably. These patients are better candidates for the Ilizarov bone transport method with or without free latissimus dorsi transfer. Copyright 2002 Wiley-Liss, Inc.
Zhu, Juanfang; Yang, Yanjie; Li, Wenlu
2014-02-01
Our aim was to evaluate the quality of life (QoL) in patients with ameloblastoma who had been treated by immediate mandibular reconstruction with a fibular free flap, and to analyse the association between QoL and their sociocultural and medical characteristics. We assessed the QoL outcomes of 33/45 patients using the University of Washington quality of life (UW-QoL) questionnaire and the 14-item Oral Health Impact Profile (OHIP-14). Thirty-three of the 45 questionnaires were returned (73%). In the UW-QoL the best-scoring domain was "shoulder", whereas the lowest scores were for "chewing" and "activity". In the OHIP-14 the lowest-scoring domain was "handicap", followed by "social disability" and "psychological discomfort". Mandibular reconstruction with a fibular free flap significantly influenced the patients' QoL and oral function. Their sociocultural data showed that most patients had a fairly low level of education. Copyright © 2013 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Surgical treatment of AVN of the fibular (lateral) sesamoid.
Waizy, Hazibullah; Jäger, Marcus; Abbara-Czardybon, Mona; Schmidt, Troy G; Frank, Daniel
2008-02-01
Despite the fact that the hallucal sesamoids play a crucial role in forefoot mechanics, disorders resulting from pathology of these structures are often overlooked or misdiagnosed. Avascular necrosis (AVN) of the hallucal sesamoids is a rare condition that must be differentiated from other pathologies, such as fractures, pseudarthrosis or osteomyelitis. We report on two patients with AVN of the fibular (lateral) hallucal sesamoid (Morbus Renander). In both patients the necrotic part of the fibular sesamoid was excised surgically after failed conservative therapy. The followup was 29 and 26 months. The clinical and radiological results showed a complete relief of pain in both patients without any complications or forefoot deformities. Recent literature and own experiences support non-operative initial management including anti-inflammatory medications, shoe modification and temporary limited weight bearing. If symptoms persist, surgical treatment with excision of the necrotic part of the sesamoid may be an alternative. Consideration by the surgeon should be given to protecting the neurovascular bundle and reattaching intrinsic tendons and ligaments if necessary. Satisfying results can be achieved by surgical removal.
Yamamoto, Masaya; Hokugo, Akishige; Takahashi, Yoshitake; Nakano, Takayoshi; Hiraoka, Masahiro; Tabata, Yasuhiko
2015-07-01
The objective of this study is to evaluate the feasibility of gelatin sponges incorporating β-tricalcium phosphate (β-TCP) granules (gelatin/β-TCP sponges) to enhance bone regeneration at a segmental ulnar defect of rabbits with X-ray irradiation. After X-ray irradiation of the ulnar bone, segmental critical-sized defects of 20-mm length were created, and bone morphogenetic protein-2 (BMP-2)-releasing gelatin/β-TCP sponges with or without autologous bone marrow were applied to the defects to evaluate bone regeneration. Both gelatin/β-TCP sponges containing autologous bone marrow and BMP-2-releasing sponges enhanced bone regeneration at the ulna defect to a significantly greater extent than the empty sponges (control). However, in the X-ray-irradiated bone, the bone regeneration either by autologous bone marrow or BMP-2 was inhibited. When combined with autologous bone marrow, the BMP-2 exhibited significantly high osteoinductivity, irrespective of the X-ray irradiation. The bone mineral content at the ulna defect was similar to that of the intact bone. It is concluded that the combination of bone marrow with the BMP-2-releasing gelatin/β-TCP sponge is a promising technique to induce bone regeneration at segmental bone defects after X-ray irradiation. Copyright © 2015 Elsevier Ltd. All rights reserved.
Modern principles of reconstructive surgery for advanced head and neck tumors
NASA Astrophysics Data System (ADS)
Kulbakin, D. E.; Choinzonov, E. L.; Mukhamedov, M. R.; Garbukov, E. U.; Shtin, V. I.; Havkin, N. M.; Vasilev, R. V.
2017-09-01
Background: Surgery remains the mainstay of treatment for head and neck cancer. Reconstruction after cancer surgery can help to restore both the appearance and function of the affected areas. Materials and methods: From 2008 to 2016, a total of 120 reconstructive surgeries were performed at the Department of Head and Neck Tumors of Tomsk Cancer Research Institute. The majority of patients had locally advanced cancer (T3 stage in 49 patients and T4 stage in 41 patients). The localizations of the defects requiring reconstruction were as follows: oral cavity—26 cases; tongue—24 cases; skin (including defects of lower lip)—12 cases; maxilla—14 cases; larynx and hypopharynx—12 cases; lips—6 cases, cheek—11 cases, and mandibulla—5 cases. Various free flaps (83%) and pedicle flaps (17%) were used for the reconstruction of the large defects following extirpation of head and neck malignant tumors. In 15 cases (13%), the implants from titanium and titanium nickelide (TiNi) were used to restore the supporting and skeletal functions of the reconstructed region. We used 3D model of the patient's skull for a more precise planning of the reconstruction of maxillofacial bone defects. Results: Good functional results were achieved in most cases. Full flap necrosis was observed in 12 cases (10%). Fibular flap necroses were noted in 8 cases (7%). Conclusions: Single-stage reconstructions of the lost structures after tumor resection significantly improve survival of head and neck cancer patients without causing significant functional and aesthetic damage, as well as contribute to quick rehabilitation of these patients and improvement of their social status. To reduce postoperative complications after reconstructive surgery, it is necessary to carefully select the appropriate reconstructive implant materials.
Jégoux, Franck; Goyenvalle, Eric; Cognet, Ronan; Malard, Olivier; Moreau, Francoise; Daculsi, Guy; Aguado, Eric
2009-12-15
The bone tissue engineering models used today are still a long way from any oncologic application as immediate postimplantation irradiation would decrease their osteoinductive potential. The aim of this study was to reconstruct a segmental critical size defect in a weight-bearing bone irradiated after implantation. Six white New Zealand rabbits were immediately implanted with a biomaterial associating resorbable collagen membrane EZ(R) filled and micro-macroporous biphasic calcium phosphate granules (MBCP+(R)). After a daily schedule of radiation delivery, and within 4 weeks, a total autologous bone marrow (BM) graft was injected percutaneously into the center of the implant. All the animals were sacrificed at 16 weeks. Successful osseous colonization was found to have bridged the entire length of the defects. Identical distribution of bone ingrowth and residual ceramics at the different levels of the implant suggests that the BM graft plays an osteoinductive role in the center of the defect. Periosteum-like formation was observed at the periphery, with the collagen membrane most likely playing a role. This model succeeded in bridging a large segmental defect in weight-bearing bone with immediate postimplantation fractionated radiation delivery. This has significant implications for the bone tissue engineering approach to patients with cancer-related bone defects.
System and process for detecting and monitoring surface defects
NASA Technical Reports Server (NTRS)
Mueller, Mark K. (Inventor)
1994-01-01
A system and process for detecting and monitoring defects in large surfaces such as the field joints of the container segments of a space shuttle booster motor. Beams of semi-collimated light from three non-parallel fiber optic light panels are directed at a region of the surface at non-normal angles of expected incidence. A video camera gathers some portion of the light that is reflected at an angle other than the angle of expected reflectance, and generates signals which are analyzed to discern defects in the surface. The analysis may be performed by visual inspection of an image on a video monitor, or by inspection of filtered or otherwise processed images. In one alternative embodiment, successive predetermined regions of the surface are aligned with the light source before illumination, thereby permitting efficient detection of defects in a large surface. Such alignment is performed by using a line scan gauge to sense the light which passes through an aperture in the surface. In another embodiment a digital map of the surface is created, thereby permitting the maintenance of records detailing changes in the location or size of defects as the container segment is refurbished and re-used. The defect detection apparatus may also be advantageously mounted on a fixture which engages the edge of a container segment.
Mechanical evaluation of anastomotic tension and patency in arteries.
Zhang, F; Lineaweaver, W C; Buntic, R; Walker, R
1996-02-01
This study quantified arterial anastomotic tension, evaluated subsequent patency rates, and examined the degree of tension reduction with vessel mobilization. The study was divided into two components. In part I, a mechanical analysis was undertaken to evaluate tension, based on the determination of the force required to deflect a cable (vessel) laterally, and its resulting lateral displacement. Six Sprague-Dawley rats with 12 femoral arteries were divided into two subgroups: 1) no mobilization; and 2) axial mobilization by ligation and transection of superficial epigastric and gracilis muscular branches. The tension of femoral arterial anastomoses was calculated in vessels with no segmental defect and with 1.5-, 3-, 4.5-, 6-, and 7.5-mm defects. In part II, patency was evaluated. Fifty-five rats with 110 femoral arteries were divided into two sub-groups as defined in part I: 1) no mobilization; and 2) axial mobilization by ligation and transection of superficial epigastric and gracilis muscular branches. Microvascular anastomoses were performed with no segmental defect and with 1-, 2-, 3-, 4-, 5-, 6-, 7-, 8-, 9-, and 10-mm segmental vessel defects. Patency was evaluated 24 hr postoperatively. Part I of the study revealed that anastomotic tension gradually increased along with an increase in the length of the vessel defect, from 1.9 to 11.34 g in the no-mobilization group and from 1.97 to 8.44 g in the axial-mobilization group. Comparison of tension linear regression coefficient showed a significant difference between the two groups (p < 0.05). In part II of the study, the maximum length of femoral artery defects still able to maintain 100 percent patency of anastomoses was 4 mm (tension approximately 6 g) in the no-mobilization group and 6 mm in the axial-mobilization group (tension approximately 6.48 g). Microanastomotic tension was related to the size of the vessel defect, with increasing tension leading to thrombosis. Axial mobilization significantly reduced the tension in vessels with segmental defects and decreased thrombosis rates.
Solitary fibular metastasis from nonsmall cell lung carcinoma
Akram, Mohammad; Zaheer, Samreen; Hussain, Asif; Siddiqui, Shahid A; Afrose, Ruquiya; Khalid, Saifullah
2017-01-01
Solitary bone metastasis to fibula in patients of lung carcinoma is a rare entity, with only four cases reported in literature. We, hereby, present a case of a 50 year-old-male who was given three cycles of chemotherapy for lung carcinoma with no distant metastasis but presented 2 months later with a fusiform, painful swelling around the knee that was clinically suspected to be inflammatory in nature but proved to be fibular metastasis on cytology. There was no evidence of skeletal metastasis on initial bone scan. He was given palliative radiotherapy for this with symptomatic relief. PMID:28469322
Solitary fibular metastasis from nonsmall cell lung carcinoma.
Akram, Mohammad; Zaheer, Samreen; Hussain, Asif; Siddiqui, Shahid A; Afrose, Ruquiya; Khalid, Saifullah
2017-01-01
Solitary bone metastasis to fibula in patients of lung carcinoma is a rare entity, with only four cases reported in literature. We, hereby, present a case of a 50 year-old-male who was given three cycles of chemotherapy for lung carcinoma with no distant metastasis but presented 2 months later with a fusiform, painful swelling around the knee that was clinically suspected to be inflammatory in nature but proved to be fibular metastasis on cytology. There was no evidence of skeletal metastasis on initial bone scan. He was given palliative radiotherapy for this with symptomatic relief.
Avulsion of the fibular head post-total knee replacement.
Phadnis, Ashish; Johnston, Phillip; Glasgow, Malcom
2007-11-01
We report a case of an avulsion of part of the fibular head during a primary total knee replacement for osteoarthritis. Post-operatively the patient developed a foot-drop. However, there was no clinically demonstrable instability of the knee. The patient was managed conservatively, the foot-drop recovered completely and the knee remained clinically stable. We observed that excessive hyperextension and/or a varus strain on the knee during pressurisation while cementing could have led to the injury. We advise caution while using this manoeuvre for pressurisation. This is the first injury of its kind reported in the literature.
Zhang, Jieyuan; Guan, Junjie; Zhang, Changqing; Wang, Hui; Huang, Wenhai; Guo, Shangchun; Niu, Xin; Xie, Zongping; Wang, Yang
2015-11-20
Bioactive borate glass (BG) has emerged as a promising alternative for bone regeneration due to its high osteoinductivity, osteoconductivity, compressive strength, and biocompatibility. However, the role of BG in large segmental bone repair is unclear and little is known about the underlying mechanism of BG's osteoinductivity. In this study, we demonstrated that BG possessed pro-osteogenic effects in an experimental model of critical-sized radius defects. Transplanting BG to radius defects resulted in better repair of bone defects as compared to widely used β-TCP. Histological and morphological analysis indicated that BG significantly enhanced new bone formation. Furthermore, the degradation rate of the BG was faster than that of β-TCP, which matched the higher bone regeneration rate. In addition, ions from BG enhanced cell viability, ALP activity, and osteogenic-related genes expression. Mechanistically, the critical genes Smad1/5 and Dlx5 in the BMP pathway and p-Smad1/5 proteins were significantly elevated after BG transplantation, and these effects could be blocked by the BMP/Smad specific inhibitor. Taken together, our findings suggest that BG could repair large segmental bone defects through activating the BMP/Smad pathway and osteogenic differentiation in BMSCs.
Software for roof defects recognition on aerial photographs
NASA Astrophysics Data System (ADS)
Yudin, D.; Naumov, A.; Dolzhenko, A.; Patrakova, E.
2018-05-01
The article presents information on software for roof defects recognition on aerial photographs, made with air drones. An areal image segmentation mechanism is described. It allows detecting roof defects – unsmoothness that causes water stagnation after rain. It is shown that HSV-transformation approach allows quick detection of stagnation areas, their size and perimeters, but is sensitive to shadows and changes of the roofing-types. Deep Fully Convolutional Network software solution eliminates this drawback. The tested data set consists of the roofing photos with defects and binary masks for them. FCN approach gave acceptable results of image segmentation in Dice metric average value. This software can be used in inspection automation of roof conditions in the production sector and housing and utilities infrastructure.
Endo, Jun; Yamaguchi, Satoshi; Saito, Masahiko; Morikawa, Tsuguo; Akagi, Ryuichiro; Sasho, Takahisa
2016-10-01
To evaluate time-dependent changes in the syndesmotic reduction after syndesmotic screw fixation and one year after screw removal for ankle malleolar fractures, and to assess whether the incidence of syndesmotic malreduction changes depending on the measurement method. We assessed twenty patients who underwent syndesmotic screw fixation for ankle fractures. The syndesmotic screws were removed after six weeks of the fracture surgery. Syndesmotic reduction was assessed within two weeks of the fracture surgery and one year after the screw removal using the axial computer tomographic images. Side-to-side differences in the anterior and posterior tibiofibular distances, anteroposterior fibular translation, and fibular rotation were measured. The mean anterior tibiofibular distance was 0.7mm after syndesmotic fixation. It increased to 1.9mm at one year after screw removal (p=0.002). After syndesmotic fixation, four ankles had malreduction of the anterior tibiofibular distance, including three ankles with widening and one with overtightening. At one year, eight ankles had malreduction, all of whom had widening. The other measurement values did not change over time (0.1mm vs. 0.6mm for the posterior tibiofibular distance, 0.2mm vs. 0.3mm for the anteroposterior fibular translation, and 0.7° vs. 0° for the fibular rotation). The incidences of malreduction were significantly different depending on the definition of malreduction, ranging from 10% to 50% after syndesmotic fixation (p=0.01) and from 20% to 60% at one year after screw removal (p=0.02). The anterior tibiofibular distance widened after one year of syndesmotic screw removal. The incidence of malreduction varied depending on the measurement method. Copyright © 2016. Published by Elsevier Ltd.
Knee arthrodesis using a vascularized fibular rotatory graft after tumor resection.
Nouri, H; Meherzi, M H; Jenzeri, M; Daghfous, M; Hdidane, R; Zehi, K; Tarhouni, L; Karray, S; Baccari, S; Mestiri, M; Zouari, M
2010-02-01
Knee arthrodesis is one of the reconstruction options for limb preservation after malignant tumor resection. Vascularised rotatory fibular transfer allows biological and, thus,definitive reconstruction. The goal of this work was to analyse the results of knee arthrodesis with vascularised fibular graft after tumor resection and to discuss the reliability of this technique. We report a retrospective series of 13 patients with an average age of 29.6 years. The pathological diagnosis was bone sarcoma in 12 cases and synovial chondrosarcoma in one case. Resection/arthrodesis was undertaken as the primary procedure in 11 cases.In two cases, arthrodesis was indicated after failure of an endoprosthesis. Reconstruction was achieved with a vascularised fibular rotatory transfer in all cases. For stabilisation, an external fixator was utilised in eight cases, a femorotibial nail in three cases, and a plate in two cases.Mean follow-up was 6 years. We encountered infection in 53% of cases, mechanical complications in 53% of cases,and nerve palsy in 23% of cases. Four patients died from metastases (only one had arthrodesis complete union). In the nine surviving patients, arthrodesis was fully united in seven cases,after an average period of 36 months. The functional score average (Enneking classification)was 20 points. Knee arthrodesis after tumor resection is a complex technique. Septic complications and mechanical failure are frequent regardless of the technique employed. They are related to the extent of bone sacrifice but also to that of soft tissues. The use of vascularised fibula alone and stabilisation by external fixation were the main shortcomings in this series. TYPE OF STUDY RETROSPECTIVE: Level IV. 2009 Published by Elsevier Masson SAS.
Piton, C; Fabre, T; Lasseur, E; André, D; Geneste, M; Durandeau, A
1997-01-01
Common peroneal nerve lesion on the lateral aspect of the knee is one of the most frequent neurologic injury of the lower limb. We reported the results of surgical procedure for each etiological group. In the peroneal nerve entrapment group, we individualised 62 fibular tunnel syndroms (55 idiopathic, 4 postural, 3 dynamic), and 16 external compression. Traumatic causes were represented by 22 varus injuries of the knee and by 11 fractures, 16 iatrogenic lesions, 2 wounds, 5 wound sequelae, 2 contusions and 1 burn. Tumoral group was represented by 7 intraneural ganglionic cyst and 2 extraneural tumour (1 exostosis and 1 chondromatosis of the proximal tibio fibular joint). All patients underwent surgical procedure. Neurolysis was performed when the nerve was in continuity. Suture or nerve grafting was performed in the other cases. In the case of intraneural ganglionic cyst, a complete tumoral excision was realised. Eighty-three per cent of excellent and good results were obtained for the fibular tunnel syndrom, 62.5 per cent for external compression, 36 per cent for varus injury of the knee, 78 per cent for the other traumatic causes and 89 per cent for tumoral lesions. This report confirms that the result depends on the etiology of the common peroneal nerve lesion. We propose surgical treatment within 2 to 4 months for the patients without clinical and electrophysiological improvement. If there is doubt on the continuity of the nerve, we propose an earlier surgical treatment. Our results were in general satisfactory except when a nerve graft was necessary furthermore if it was a traction injury and if the length of the graft was longer than 6 centimeters.
Chalopin, A; Geffroy, L; Pesenti, S; Hamel, A; Launay, F
2017-09-01
Childhood fibular hypoplasia is a rare pathology which may or may not involve limb-length discrepancy and axial deformity in one or more dimensions. The objective of the present study was to compare the quality of the axial correction achieved in lengthening procedures by hexapodal versus monorail external fixators. The hypothesis was that the hexapodal fixator provides more precise correction. A retrospective multicenter study included 52 children with fibular hypoplasia. Seventy-two tibias were analyzed, in 2 groups: 52 using a hexapodal fixator, and 20 using a monorail fixator. Mean age was 10.2 years. Mean lengthening was 5.7cm. Deformities were analyzed and measured in 3 dimensions and classified in 4 preoperative types and 4 post-lengthening types according to residual deformity. Complete correction was achieved in 26 tibias in the hexapodal group (50%) and 2 tibias in the monorail group (10%). Mean post-correction mechanical axis deviation was smaller in the hexapodal group: 12.83mm, versus 14.29mm in the monorail group. Mean post-correction mechanical lateral distal femoral angle was 87.5° in the hexapodal group, versus 84.3° in the monorail group (P=0.002), and mean mechanical medial proximal tibial angle 86.9° versus 89.5°, respectively (P=0.015). No previous studies focused on this congenital pathology in lengthening and axial correction programs for childhood lower-limb deformity. The present study found the hexapodal fixator to be more effective in conserving or restoring mechanical axes during progressive bone lengthening for fibular hypoplasia. The hexapodal fixator met the requirements of limb-length equalization in childhood congenital lower-limb hypoplasia, providing better axial correction than the monorail fixator. IV. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Slower nerve conduction velocity in individuals with functional ankle instability.
Simon, J; Docherty, C
2014-08-01
The purpose of this study is to quantify nerve conduction velocity differences in individuals with functional ankle instability compared to a "healthy" population. 38 participants ages 18-30 were recruited from a large university with approximately 43,000 students. 19 subjects (9 men and 10 women; age=21.0±1.4 years; height=172.0±9.3 cm; mass=74.4±1 2.4 kg) with symptoms of functional ankle instability were in the functional ankle instability group. 19 subjects (10 men, 9 women; age=22.0±2.6 years; height=169.8±9.1 cm; mass=69.0±14.8 kg) with "healthy" ankles were in the control group. Nerve conduction velocity was conducted using one trial at 2 different sites: posterior to the fibular head (fibular), and 10 cm superior/posterior of the first site (popliteal). Nerve conduction velocity (m/sec) was assessed using a SierraWave II system (Cadwell Laboratories; Kennewick, WA). A MANCOVA was performed on the two dependent variables (fibular and popliteal). Covariates included surface temperature of the leg, body mass index, and age. The independent variable was group (functional ankle instability and control). The effect of group was significantly related to nerve conduction velocity at the fibular site (F(1, 27) =16.49, p=0.01) and popliteal site (F(1, 27)=4.51, p=0.01), with responses significantly faster for individuals in the control group than the functional ankle instability group. These results indicate that patients with functional ankle instability might have damage to the peroneal nerve which results in slower peroneal nerve conduction velocity. © Georg Thieme Verlag KG Stuttgart · New York.
Chang, Y-M; Pan, Y-H; Shen, Y-F; Chen, J-K; ALDeek, N F; Wei, F-C
2016-12-01
We have evaluated the survival of dental implants placed in vascularised fibular flap onlay grafts placed over marginal mandibulectomies and the effects on marginal bone loss of different types of soft tissue around implants under functional loading. From 2001-2009 we studied a total of 11 patients (1 woman and10 men), three of whom had had ameloblastoma and eight who had had squamous cell carcinomas resected. A total of 38 dental implants were placed either at the time of transfer of the vascularised fibular ostoseptocutaneous flaps (nine patients with 30 implants) or secondarily (two patients with eight implants). Four patients were given palatal mucosal grafts to replace intraoral skin flaps around the dental implants (n=13), and the other seven had the skin flaps around the dental implants thinned (n=25) at the second stage of implantation of the osteointegrated teeth. All vascularised fibular osteoseptocutaneous flaps were successfully transferred, and all implants survived a mean (range) of 73 (33-113) months after occlusal functional loading. The mean (SD) marginal bone loss was 0.5 (0.3) mm on both mesial and distal sides in patients who had palatal mucosal grafts, but 1.8 (1.6) mm, and 1.7 (1.5) mm, respectively, on the mesial and distal sides in the patients who had had thinning of their skin flaps. This difference is significant (p=0.008) with less resorption of bone in the group who had palatal mucosal grafts. Palatal mucosa around the implants helps to reduce resorption of bone after functional loading of implants. Copyright © 2016 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Chien, David T; Bravo, Paco; Higuchi, Takahiro; Merrill, Jennifer; Bengel, Frank M
2011-08-01
Myocardial washout of the potassium analogue (82)Rb may indicate tissue impairment. Few studies have evaluated its usefulness for viability assessment, and controversial results were reported. We revisited this topic using list-mode positron emission tomography (PET)/CT. A total of 22 patients with chronic ischemic cardiomyopathy (ICM) and 11 control subjects with normal CT coronary angiogram were studied. Rest (82)Rb PET/CT studies were acquired in list mode and resampled to static, gated, and dynamic images. Using a 17-segment model, (82)Rb washout was determined by monoexponential fitting of myocardial time-activity curves. In ICM patients, (18)F-fluorodeoxyglucose (FDG) studies were obtained in the same session and segments were classified as normally perfused, mismatch, or matched defect. (82)Rb washout was minimal and homogeneous in control subjects. Normally perfused segments of ICM did not differ (p = 0.33). ICM patients had a left ventricular ejection fraction (LVEF) of 25 ± 12%, 25/353 mismatched, and 46/353 matched defect segments. (82)Rb washout was higher in hypoperfused vs normal segments (p < 0.05), but not different between mismatch and matched defect (p = 0.18). Intraindividual analysis in nine patients showing both FDG mismatch and matched defect confirmed absence of differences. Overall, segmental (82)Rb washout correlated inversely with (82)Rb uptake (r = -0.70; p < 0.05) and less well with FDG uptake (r = -0.31; p < 0.05). Using state-of-the-art PET/CT technology for myocardial viability assessment, (82)Rb washout does not distinguish between perfusion/metabolism patterns of hibernating myocardium and scar. Tissue integrity may be at least partially impaired in hibernation.
Feng, Ya-Fei; Li, Xiang; Hu, Yun-Yu; Wang, Zhen; Ma, Zhen-Sheng; Lei, Wei
2014-01-01
Background The basic strategy to construct tissue engineered bone graft (TEBG) is to combine osteoblastic cells with three dimensional (3D) scaffold. Based on this strategy, we proposed the “Totally Vitalized TEBG” (TV-TEBG) which was characterized by abundant and homogenously distributed cells with enhanced cell proliferation and differentiation and further investigated its biological performance in repairing segmental bone defect. Methods In this study, we constructed the TV-TEBG with the combination of customized flow perfusion seeding/culture system and β-tricalcium phosphate (β-TCP) scaffold fabricated by Rapid Prototyping (RP) technique. We systemically compared three kinds of TEBG constructed by perfusion seeding and perfusion culture (PSPC) method, static seeding and perfusion culture (SSPC) method, and static seeding and static culture (SSSC) method for their in vitro performance and bone defect healing efficacy with a rabbit model. Results Our study has demonstrated that TEBG constructed by PSPC method exhibited better biological properties with higher daily D-glucose consumption, increased cell proliferation and differentiation, and better cell distribution, indicating the successful construction of TV-TEBG. After implanted into rabbit radius defects for 12 weeks, PSPC group exerted higher X-ray score close to autograft, much greater mechanical property evidenced by the biomechanical testing and significantly higher new bone formation as shown by histological analysis compared with the other two groups, and eventually obtained favorable healing efficacy of the segmental bone defect that was the closest to autograft transplantation. Conclusion This study demonstrated the feasibility of TV-TEBG construction with combination of perfusion seeding, perfusion culture and RP technique which exerted excellent biological properties. The application of TV-TEBG may become a preferred candidate for segmental bone defect repair in orthopedic and maxillofacial fields. PMID:24728277
Patterns of pulmonary perfusion scans in normal subjects
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wallace, J.M.; Moser, K.M.; Hartman, M.T.
1981-01-01
A vital factor conditioning the usage of the pulmonary perfusion (Q) scan in the evaluation of patients suspected of pulmonary embolism is the prevalence of abnormal Q scans in subjects free of cardiopulmonary disease. Because this prevalence has not been well defined, we performed Q scans in 80 nonsmoking subjects 18 to 29 yr of age having no known active cardiopulmonary disease. Each subject underwent a history, physical examination, electrocardiogram, spirometry, and PA chest roentgenogram, followed by a 6-view Q scan. Two subjects in whom a Q defect was suspected underwent a /sup 133/Xe equilibrium-washout ventilation (V) scan. All Qmore » scans were interpreted blindly and independently by 2 experienced readers. Seventy-nine of the 80 Q scans were read as normal. No subject demonstrated a lobar or segmental defect. One of the 80 subjects, who had a mild pectus excavatum, had a left upper lobe subsegmental defect, which was not seen on the V scan. Based on the statistical analysis of these data, no more than 3.68% of normal nonsmoking persons in this age group may have a lobar or segmental Q scan defect and no more than 6.77% may have a subsegmental defect (with 95% confidence). Therefore, our study indicated that Q scan defects, particularly lobar or segmental, are rarely present among normal nonsmokers in this age group.« less
Tsitskaris, Konstantinos; Havard, Heledd; Bijlsma, Paulien; Hill, Robert A
2016-04-01
Bone transport techniques can be used to address the segmental bone loss occurring after debridement for infection. Secure fixation of the bone transport construct to the bone transport segment can be challenging, particularly if the bone is small and osteopenic. We report a case of a segmental ulnar bone defect in a young child treated with internal bone transport using a cannulated screw as the mounting device. We found this technique particularly useful in the treatment of bone loss secondary to infection, where previous treatment and prolonged immobilisation had led to osteopenia. This technique has not been previously reported.
Canales, Michael; Gerhard, John; Younce, Erin
2015-06-01
Presented is a rare case of tibial and fibular osteomyelitis and a case of fibular periositis, both a direct consequence of a peculiar drug use technique. The osseous manifestations secondary to presentation of necrotic wounds with indurated rim and serous drainage with associated cellulitis, both resulting from "skin popping." Due to the complex treatment plan required, the importance of a motivated patient, a strong social support system, a controlled environment, and a multidisciplinary team cannot be overstated. Despite comprehensive efforts, devastating consequences may be unavoidable as individuals plunge downward, victimized by their addiction. 4. Copyright © 2015 Elsevier Ltd. All rights reserved.
Comparison of four different nerve conduction techniques of the superficial fibular sensory nerve.
Saffarian, Mathew R; Condie, Nathan C; Austin, Erica A; Mccausland, Katie E; Andary, Michael T; Sylvain, James R; Mull, Iian R; Zemper, Eric D; Jannausch, Mary L
2017-09-01
There are many different nerve conduction study (NCS) techniques to study the superficial fibular sensory nerve (SFSN). We present reference distal latency values and comparative data regarding 4 different NCS for the SFSN. Four different NCS techniques, Spartan technique, Izzo techniques (medial and intermediate dorsal cutaneous branches), and Daube technique, were performed on (114) healthy volunteers. A total of 108 subjects with 164 legs were included. The mean latency of the Spartan technique was longest (3.9 ± 0.3 ms) while the Daube technique was the shortest (3.6 ± 0.7 ms). The mean amplitude of the Daube technique displayed the highest (15.2 ± 8.2 μV) with the Spartan technique having the lowest (8.7 ± 4.2 μV). Among the absent sensory nerve action potentials (SNAPs), the Spartan technique was absent only twice (1.2%) and the Izzo Medial technique was absent more than the other techniques (2.9%). All 4 techniques were reliable methods for obtaining the superficial fibular nerve SNAP, present in 95% of individuals. Muscle Nerve 56: 458-462, 2017. © 2017 Wiley Periodicals, Inc.
Shaikh, Ayaz Hussain; Hanif, Bashir; Siddiqui, Adeel M; Shahab, Hunaina; Qazi, Hammad Ali; Mujtaba, Iqbal
2010-04-01
To determine the association of prolonged ST segment depression after an exercise test with severity of coronary artery disease. A cross sectional study of 100 consecutive patients referred to the cardiology laboratory for stress myocardial perfusion imaging (MPI) conducted between April-August 2008. All selected patients were monitored until their ST segment depression was recovered to baseline. ST segment recovery time was categorized into less and more than 5 minutes. Subsequent gated SPECT-MPI was performed and stratified according to severity of perfusion defect. Association was determined between post exercise ST segment depression recovery time (<5 minutes and >5 minutes) and severity of perfusion defect on MPI. The mean age of the patients was 57.12 +/- 9.0 years. The results showed statistically insignificant association (p > 0.05) between ST segment recovery time of <5 minutes and >5 minutes with low, intermediate or high risk MPI. Our findings suggest that the commonly used cut-off levels used in literature for prolonged, post exercise ST segment depression (>5 minutes into recovery phase) does not correlate with severity of ischaemia based on MPI results.
A Novel Machine Vision System for the Inspection of Micro-Spray Nozzle
Huang, Kuo-Yi; Ye, Yu-Ting
2015-01-01
In this study, we present an application of neural network and image processing techniques for detecting the defects of an internal micro-spray nozzle. The defect regions were segmented by Canny edge detection, a randomized algorithm for detecting circles and a circle inspection (CI) algorithm. The gray level co-occurrence matrix (GLCM) was further used to evaluate the texture features of the segmented region. These texture features (contrast, entropy, energy), color features (mean and variance of gray level) and geometric features (distance variance, mean diameter and diameter ratio) were used in the classification procedures. A back-propagation neural network classifier was employed to detect the defects of micro-spray nozzles. The methodology presented herein effectively works for detecting micro-spray nozzle defects to an accuracy of 90.71%. PMID:26131678
A Novel Machine Vision System for the Inspection of Micro-Spray Nozzle.
Huang, Kuo-Yi; Ye, Yu-Ting
2015-06-29
In this study, we present an application of neural network and image processing techniques for detecting the defects of an internal micro-spray nozzle. The defect regions were segmented by Canny edge detection, a randomized algorithm for detecting circles and a circle inspection (CI) algorithm. The gray level co-occurrence matrix (GLCM) was further used to evaluate the texture features of the segmented region. These texture features (contrast, entropy, energy), color features (mean and variance of gray level) and geometric features (distance variance, mean diameter and diameter ratio) were used in the classification procedures. A back-propagation neural network classifier was employed to detect the defects of micro-spray nozzles. The methodology presented herein effectively works for detecting micro-spray nozzle defects to an accuracy of 90.71%.
Light-leaking region segmentation of FOG fiber based on quality evaluation of infrared image
NASA Astrophysics Data System (ADS)
Liu, Haoting; Wang, Wei; Gao, Feng; Shan, Lianjie; Ma, Yuzhou; Ge, Wenqian
2014-07-01
To improve the assembly reliability of Fiber Optic Gyroscope (FOG), a light leakage detection system and method is developed. First, an agile movement control platform is designed to implement the pose control of FOG optical path component in 6 Degrees of Freedom (DOF). Second, an infrared camera is employed to capture the working state images of corresponding fibers in optical path component after the manual assembly of FOG; therefore the entire light transmission process of key sections in light-path can be recorded. Third, an image quality evaluation based region segmentation method is developed for the light leakage images. In contrast to the traditional methods, the image quality metrics, including the region contrast, the edge blur, and the image noise level, are firstly considered to distinguish the image characters of infrared image; then the robust segmentation algorithms, including graph cut and flood fill, are all developed for region segmentation according to the specific image quality. Finally, after the image segmentation of light leakage region, the typical light-leaking type, such as the point defect, the wedge defect, and the surface defect can be identified. By using the image quality based method, the applicability of our proposed system can be improved dramatically. Many experiment results have proved the validity and effectiveness of this method.
Chu, Tien-Min G.; Warden, Stuart J.; Turner, Charles H.; Stewart, Rena L.
2006-01-01
Segmental defect regeneration has been a clinical challenge. Current tissue engineering approach using porous biodegradable scaffolds to delivery osteogenic cells and growth factors demonstrated success in facilitating bone regeneration in these cases. However, due to the lack of mechanical property, the porous scaffolds were evaluated in non-load bearing area or were stabilized with stress-shielding devices (bone plate or external fixation). In this paper, we tested a scaffold that does not require a bone plate because it has sufficient biomechanical strength. The tube-shaped scaffolds were manufactured from poly(propylene) fumarate/tricalcium phosphate (PPF/TCP) composites. Dicalcium phosphate dehydrate (DCPD) were used as bone morphogenetic protein -2 (BMP-2) carrier. Twenty two scaffolds were implanted in 5 mm segmental defects in rat femurs stabilized with k-wire for 6 and 15 weeks with and without 10 μg of rhBMP-2. Bridging of the segmental defect was evaluated first radiographically and was confirmed by histology and micro- computer tomography (μ-CT) imaging. The scaffolds in the BMP group maintained the bone length throughout the duration of the study and allow for bridging. The scaffolds in the control group failed to induce bridging and collapsed at 15 weeks. Peripheral computed tomography (pQCT) showed that BMP-2 does not increase the bone mineral density in the callus. Finally, the scaffold in BMP group was found to restore the mechanical property of the rat femur after 15 weeks. Our results demonstrated that the load-bearing BMP-2 scaffold can maintain bone length and allow successfully regeneration in segmental defects. PMID:16996588
Cheng, Bi-Hua; Chu, Tien-Min G.; Chang, Chawnshang; Kang, Hong-Yo; Huang, Ko-En
2013-01-01
Loss of large bone segments due to fracture resulting from trauma or tumor removal is a common clinical problem. The goal of this study was to evaluate the use of scaffolds containing testosterone, bone morphogenetic protein-2 (BMP-2), or a combination of both for treatment of critical-size segmental bone defects in mice. A 2.5-mm wide osteotomy was created on the left femur of wildtype and androgen receptor knockout (ARKO) mice. Testosterone, BMP-2, or both were delivered locally using a scaffold that bridged the fracture. Results of X-ray imaging showed that in both wildtype and ARKO mice, BMP-2 treatment induced callus formation within 14 days after initiation of the treatment. Testosterone treatment also induced callus formation within 14 days in wildtype but not in ARKO mice. Micro-computed tomography and histological examinations revealed that testosterone treatment caused similar degrees of callus formation as BMP-2 treatment in wildtype mice, but had no such effect in ARKO mice, suggesting that the androgen receptor is required for testosterone to initiate fracture healing. These results demonstrate that testosterone is as effective as BMP-2 in promoting the healing of critical-size segmental defects and that combination therapy with testosterone and BMP-2 is superior to single therapy. Results of this study may provide a foundation to develop a cost effective and efficient therapeutic modality for treatment of bone fractures with segmental defects. PMID:23940550
Left ventricular rotation and torsion in patients with perimembranous ventricular septal defect.
Zhuang, Yan; Yong, Yong-hong; Yao, Jing; Ji, Ling; Xu, Di
2014-03-01
Assessment of left ventricular (LV) rotation has become an important approach for quantifying LV function. In this study, we sought to analyze LV rotation and twist using speckle tracking imaging (STI) in adult patients with isolated ventricular septal defects. Using STI, the peak rotation and time to peak rotation of 6 segments in basal and apical short-axis were measured, respectively, in 32 patients with ventricular septal defect and 30 healthy subjects as controls. The global rotation of the 6 segments in basal and apical and LV twist versus time profile were drawn, the peak rotation and twist of LV were calculated. All the time to peak rotation/twist were expressed as a percentage of end-systole (end-systole = 100%). Left ventricular ejection fraction was measured by biplane Simpson method. In patients group, the peak rotation of posterior, inferior, and postsept wall in basal was higher(P ≤ 0.05) and LV twist was also higher (P ≤ 0.05) than healthy controls. There were no significant differences between 2 groups in the peak rotation of the other 9 segments and left ventricular ejection fraction. Different from the control group, the time to peak rotation of the 6 segments in basal were delayed and the global rotation of the base was delayed (P ≤ 0.05) in ventricular septal defect group. Left ventricular volume overload due to ventricular septal defect has significant effect on LV rotation and twist, and LV rotation and twist may be a new index predicting LV systolic function. © 2013, Wiley Periodicals, Inc.
Preliminary evaluation of a load-bearing BMP-2 carrier for segmental defect regeneration.
Chu, Tien-Min G; Sargent, Peter; Warden, Stuart J; Turner, Charles H; Stewart, Rena L
2006-01-01
Large segmental defects in bones can result from tumor removal, massive trauma, congenital malformation, or non-union fractures. Such defects often are difficult to manage and require multiple-phase surgery to achieve adequate union and function. In this study, we propose a novel design of bone morphogenetic protein 2 (BMP-2) carrier for tissue engineering of segmental defect regeneration. The tube-shaped BMP-2 carrier was fabrication from a poly(propylene fumarate)/tricalcium phosphate (PPF/TCP) composite via casting technique developed in our laboratory. An in vitro evaluation showed that the compressive strength of the carrier decreased about 48% in 12 weeks while maintained a pH in the 6.8-7.4 range. In vivo study was conducted by implanting carriers loaded with 10 microg of BMP-2 in 5 mm rat femur gap model for 15 weeks. X-ray evidence of bridging was first found in the BMP group at 3 weeks. Bridging in all animals (N = 4) in the BMP group was found at 9 weeks. No x-ray evidence of bridging was found in the No BMP group (N = 3). pQCT analysis indicated that the bone mineral density of the callus in the BMP group has reached the level of native femur at 15 weeks after implantation, while the callus in the No BMP group has a bone mineral density at a lower level of 84% to the native femur. Histology analysis shows that a normal fatty bone marrow was restored and mineralized callus formed and bridged the segmental defect.
Huang, Guofeng; Liu, Guojun; Zhang, Feng; Gao, Jianting; Wang, Jiangze; Chen, Qi; Wu, Benwen; Ding, Zhenqi; Cai, Taoyi
2017-01-01
Under physiological conditions bone defects often occur at mechanical load bearing sites and bone substitutes used for regeneration should be similarly subjected to mechanical loading stress. In this study, we investigated whether a novel heel-strike like mechanical loading method can be used as a complementary therapy to promote bone regeneration following bone substitute grafting. To test this, three groups of rabbits with segmental bone defects in the tibia were implanted with bovine deproteinized cancellous bone scaffold (DCBS), with one group also receiving heel-strike like mechanical loading generated by a rap stress stimulator. From weeks 4-12 post-operation X-ray and micro-CT scanning showed that rabbits receiving combination therapy had significantly more callus at the bone defect. Moreover, bone defects in the combination group were completely replaced with new bone at week 12, while the DCBS implantation alone group healed only partially and rabbits receiving neither DCBS nor mechanical loading developed only small calluses throughout the observation period. Analysis of micro-CT scanning results demonstrated that new bone density in the combination group was significantly higher than the DCBS only group at weeks 4 and 12 ( p <0.05). H&E staining results also indicated a significantly higher percentage of new bone in the bone defect area and a lower percentage of residual scaffold in the combination group compared to the DCBS only group ( p <0.05). Thus, this heel-strike like mechanical loading method appears to accelerate bone regeneration following substitute implantation by restoring a local mechanical loading environment in segmental bone defects.
Primary versus secondary achalasia: New signs on barium esophagogram
Gupta, Pankaj; Debi, Uma; Sinha, Saroj Kant; Prasad, Kaushal Kishor
2015-01-01
Aim: To investigate new signs on barium swallow that can differentiate primary from secondary achalasia. Materials and Methods: Records of 30 patients with primary achalasia and 17 patients with secondary achalasia were reviewed. Clinical, endoscopic, and manometric data was recorded. Barium esophagograms were evaluated for peristalsis and morphology of distal esophageal segment (length, symmetry, nodularity, shouldering, filling defects, and “tram-track sign”). Results: Mean age at presentation was 39 years in primary achalasia and 49 years in secondary achalasia. The mean duration of symptoms was 3.5 years in primary achalasia and 3 months in secondary achalasia. False-negative endoscopic results were noted in the first instance in five patients. In the secondary achalasia group, five patients had distal esophageal segment morphology indistinguishable from that of primary achalasia. None of the patients with primary achalasia and 35% patients with secondary achalasia had a length of the distal segment approaching combined height of two vertebral bodies. None of the patients with secondary achalasia and 34% patients with primary achalasia had maximum caliber of esophagus approaching combined height of two vertebral bodies. Tertiary contractions were noted in 90% patients with primary achalasia and 24% patients with secondary achalasia. Tram-track sign was found in 55% patients with primary achalasia. Filling defects in the distal esophageal segment were noted in 94% patients with secondary achalasia. Conclusion: Length of distal esophageal segment, tertiary contractions, tram-track sign, and filling defects in distal esophageal segment are useful esophagographic features distinguishing primary from secondary achalasia. PMID:26288525
A cascade method for TFT-LCD defect detection
NASA Astrophysics Data System (ADS)
Yi, Songsong; Wu, Xiaojun; Yu, Zhiyang; Mo, Zhuoya
2017-07-01
In this paper, we propose a novel cascade detection algorithm which focuses on point and line defects on TFT-LCD. At the first step of the algorithm, we use the gray level difference of su-bimage to segment the abnormal area. The second step is based on phase only transform (POT) which corresponds to the Discrete Fourier Transform (DFT), normalized by the magnitude. It can remove regularities like texture and noise. After that, we improve the method of setting regions of interest (ROI) with the method of edge segmentation and polar transformation. The algorithm has outstanding performance in both computation speed and accuracy. It can solve most of the defect detections including dark point, light point, dark line, etc.
Toward Patient Specific Long Lasting Metallic Implants for Mandibular Segmental Defects
NASA Astrophysics Data System (ADS)
Shayesteh Moghaddam, Narges
Mandibular defects may result from tumor resection, trauma, or inflammation. The goals of mandibular reconstruction surgeries are to restore mandible function and aesthetics. To this end, surgeons use a combination of bone grafts and metallic implants. These implants have drastically different mechanical properties than the surrounding bone. As a result, the stress distribution in the mandible changes after surgery. The long-term abnormal stress/strain distribution may lead to either graft failure due to bone resorption as a result of stress shielding, or hardware failure due to stress concentrations. During the healing period of six to nine months it is important that complete immobilization, bringing mandibular micro-motion down to the level of 200-500 mum during chewing, is achieved. After this period it is desired that bone undergo normal stress for long-term success of the treatment. Although current high stiffness fixation hardware accomplishes this immobilization during the healing period, the hardware continues to alter the normal stress-strain trajectory seen during chewing once the engrafted bone heals. Over the long-term, the immobilized and stress-shielded engrafted bone tends to resorb. On the other hand, hardware fracturing or/and screw loosening is observed as the stress is concentrated at certain locations on the hardware. Equally as important is the permanent loss of chewing power due to the altered stress-strain relationships. The first stage of this research is to study the problems encountered following a mandibular segmental defect reconstructive surgery. To this end, we constructed a finite element model of a healthy mandible, which includes cortical and cancellous bone, teeth (enamel and dentin components), and the periodontal ligament. Using this model, we studied a healthy adult mandible under maximum molar bite force for stress, strain, displacement, and reaction force distribution. For mandibular segmental defect reconstruction the current standard of care consists of the use of Surgical Grade 5 titanium also known as Ti-6Al-4V hardware and either a single or double fibula barrel vascularized bone graft. We expanded our model to simulate the effects of this surgery. The expanded model includes both single and double barrel fibular bone graft repair of a right M1-M3 containing section of the mandible, Ti-6Al-4V fixation hardware and screws. We found that the stiffness mismatch between the fixation hardware and the bone causes stress shielding on the host mandible and the bone graft, and stress concentration at the fixation hardware and screws. The simulations results show that while a double-barrel graft is preferred, in the long-term it does not create the optimal outcome due to the abnormal stress pattern. To improve the long-term outcome with metallic implants it is essential to recreate the normal stress pattern. To achieve this outcome we investigated the use of porous nitinol as a substitute for the currently used titanium hardware. While NiTi already has a lower stiffness than titanium, it is possible to add porosity to further reduce the stiffness to be closer to that of cortical bone. The ultimate goal is to create fixation hardware that has sufficient stiffness for immobilization while recreating the normal stress pattern in the bone. Using a finite element model of devices fabricated from Surgical Grade 5 titanium and NiTi, we have found that stiffness-tuned NiTi hardware with conventional geometries should result in recreation of normal stress-strain trajectories and better treatment outcome. Finally, to further improve the outcome, we suggest the use of a two-stage mechanism Bone Bandaid which supports both the immobilization/healing and regenerative phases of mandibular segmental defect treatment. This device is made of two materials. The stiff Ti-6Al-4V portion provides the support during the healing period and is disengaged afterwards. The second material is a NiTi wire-frame to facilitate normal stress distribution after the initial healing period. The titanium part of this fixation hardware is released following radiological verification that the surgical osteotomies have healed. The release procedure is performed under local anesthetic via a microsurgical tool. With the titanium fixation hardware no longer functional, the NiTi webbing would act as a superstructure, like a skin, to the underlying grafted cortical bone. This device facilitates stress transduction through the normal stress-strain trajectories, allows restoration of power, drives cortical bone remodeling and strengthening, provides long-term strength, and a good bone bed for dental implants. If bone chips are used, instead of single or double bone graft, the webbing is more likely to support the bone chips while they are being incorporated with the mandible. We have performed computer simulation to investigate the two stages of the operation of the device. Our FEA results indicate that the Bone Bandaid supports both the immobilization needed during healing and the distribution of stress through the engrafted bone once it has healed. (Abstract shortened by ProQuest.).
Giant cell tumour 2nd metatarsal-Result with en-bloc excision and autologous fibular grafting.
Agarwal, Saurabh; Chawla, Sumit; Agarwal, Sippy; Agarwal, Puneet
2015-12-01
Giant cell tumour (GCT) of the small bones is relatively uncommon tumour. It occurs most commonly in the distal portions of femur and radius and proximal end of tibia. GCT of small bones presents at advanced stages with major bony destruction. These tumours represent more aggressive course; associated with increased local recurrence rates (40%) and metastasis. Various treatment modalities like en-bloc resection, cryosurgery, intralesional curettage with burring/phenolization or bone cement are available. In our case en-bloc resection with reconstruction using nonvascular autogenous fibular strut graft was used in patient of 2nd metatarsal GCT and a favourable functional outcome was observed. Copyright © 2015 Elsevier Ltd. All rights reserved.
Qu, Huayi; Guo, Wei; Yang, Rongli; Li, Dasen; Tang, Shun; Yang, Yi; Dong, Sen; Zang, Jie
2015-09-24
The reconstruction of an intercalary bone defect after a tumor resection of a long bone remains a challenge to orthopedic surgeons. Though several methods have been adopted to enhance the union of long segmental allografts or retrieved segmental autografts to the host bones, still more progresses are required to achieve a better union rate. Several methods have been adopted to devitalize tumor bone for recycling usage, and the results varied. We describe our experiences of using devitalized tumor-bearing bones for the repairing of segmental defects after tumor resection. Twenty-seven eligible patients treated from February 2004 to May 2012 were included. The segmental tumor bone (mean length, 14 cm) was resected, and then devitalized in 20% sterile saline at 65 °C for 30 min after the tumor tissue was removed. The devitalized bone was implanted back into the defect by using nails or plates. Complete healing of 50 osteotomy ends was achieved at a median time of 11 months (interquartile range (IQR) 9-13 months). Major complications included bone nonunion in four bone junctions (7.4%), devitalized bone fracture in one patient (3.7%), deep infection in three patients (11.1%), and fixation failure in two patients (7.4%). The bone union rates at 1 and 2 years were 74.1 and 92.6%, respectively. The average functional score according to the Musculoskeletal Tumor Society (MSTS) 93 scoring system was 93 % (IQR 80-96.7%). Incubation in 20% sterile saline at 65 °C for 30 min is an effective method of devitalization of tumor-bearing bone. The retrieved bone graft may provide as a less expensive alternative for limb salvage. The structural bone and the preserved osteoinductivity of protein may improve bone union.
Li, Wenhuan; Zhu, Xiaolian; Li, Jing; Peng, Cheng; Chen, Nan; Qi, Zhigang; Yang, Qi; Gao, Yan; Zhao, Yang; Sun, Kai; Li, Kuncheng
2014-12-01
The sensitivity and specificity of 5 different image sets of dual-energy computed tomography (DECT) for the detection of first-pass myocardial perfusion defects have not systematically been compared using positron emission tomography (PET) as a reference standard. Forty-nine consecutive patients, with known or strongly suspected of coronary artery disease, were prospectively enrolled in our study. Cardiac DECT was performed at rest state using a second-generation 128-slice dual-source CT. The DECT data were reconstructed to iodine maps, monoenergetic images, 100 kV images, nonlinearly blended images, and linearly blended images by different postprocessing techniques. The myocardial perfusion defects on DECT images were visually assessed by 5 observers, using standard 17-segment model. Diagnostic accuracy of 5 image sets was assessed using nitrogen-13 ammonia PET as the gold standard. Discrimination was quantified using the area under the receiver operating characteristic curve (AUC), and AUCs were compared using the method of DeLong. The DECT and PET examinations were successfully completed in 30 patients and a total of 90 territories and 510 segments were analyzed. Cardiac PET revealed myocardial perfusion defects in 56 territories (62%) and 209 segments (41%). The AUC of iodine maps, monoenergetic images, 100 kV images, nonlinearly blended images, and linearly blended images were 0.986, 0.934, 0.913, 0.881, and 0.871, respectively, on a per-territory basis. These values were 0.922, 0.813, 0.779, 0.763, and 0.728, respectively, on a per-segment basis. DECT iodine maps shows high sensitivity and specificity, and is superior to other DECT image sets for the detection of myocardial perfusion defects in the first-pass myocardial perfusion.
An improved segmentation method for defects inspection on steel roller surface
NASA Astrophysics Data System (ADS)
Xu, Jirui; Li, Xuekun; Cao, Yuzhong; Shi, Depeng; Yang, Jun; Jiang, Sheng; Rong, Yiming
2018-05-01
In the field of metal rolling, the quality of the steel roller's surface is significant for the final rolling products, e.g. metal sheets or foils. Besides the dimensional accuracy and surface roughness, the optical uniformity of the roller surface is also required for high quality rolling application. The typical optical defects of rollers after finish grinding include speckles, chatter marks, feed traces, and combination of all above. Unlike surface roughness, the optical defects can hardly be characterized by the topography or scanning electrical microscope measurement. Only the inspection by bared eyes of experienced engineers appears to be the effective manner for surface optical defects examination for large steel rollers. In this paper, an on-site machine vision system is designed to add on to the roller grinding machine to capture the surface image, and then an improved optical defects segmentation algorithm is developed based on the active contour model. Finally, experiments are carried out to verify the efficacy of the improved model.
Boonzaier, James; Vicatos, George; Hendricks, Rushdi
2015-01-01
The bones of the maxillary complex are vital for normal oro-nasal function and facial cosmetics. Maxillary tumor excision results in large defects that commonly include segments of the alveolar and palatine processes, compromising eating, speech and facial appearance. Unlike the conventional approach to maxillary defect repair by vascularized bone grafting, transport disc distraction osteogenesis (TDDO) stimulates new bone by separating the healing callus, and stimulates growth of surrounding soft tissues as well. Bone formed in this way closely mimics the parent bone in form and internal structure, producing a superior anatomical, functional and cosmetic result. Historically, TDDO has been successfully used to close small horizontal cleft defects in the maxilla, not exceeding 25 mm. Fujioka et al. reported in 2012 that “no bone transporter corresponding to the (large) size of the oro-antral fistula is marketed. The authors report the successful treatment of 4 cases involving alveolar defects of between 25 mm and 80 mm in length. PMID:26389041
Custom-made composite scaffolds for segmental defect repair in long bones.
Reichert, Johannes C; Wullschleger, Martin E; Cipitria, Amaia; Lienau, Jasmin; Cheng, Tan K; Schütz, Michael A; Duda, Georg N; Nöth, Ulrich; Eulert, Jochen; Hutmacher, Dietmar W
2011-08-01
Current approaches for segmental bone defect reconstruction are restricted to autografts and allografts which possess osteoconductive, osteoinductive and osteogenic properties, but face significant disadvantages. The objective of this study was to compare the regenerative potential of scaffolds with different material composition but similar mechanical properties to autologous bone graft from the iliac crest in an ovine segmental defect model. After 12 weeks, in vivo specimens were analysed by X-ray imaging, torsion testing, micro-computed tomography and histology to assess amount, strength and structure of the newly formed bone. The highest amounts of bone neoformation with highest torsional moment values were observed in the autograft group and the lowest in the medical grade polycaprolactone and tricalcium phosphate composite group. The study results suggest that scaffolds based on aliphatic polyesters and ceramics, which are considered biologically inactive materials, induce only limited new bone formation but could be an equivalent alternative to autologous bone when combined with a biologically active stimulus such as bone morphogenetic proteins.
Nair, Manitha B; Varma, H K; Menon, K V; Shenoy, Sachin J; John, Annie
2009-06-01
Segmental bone defects resulting from trauma or pathology represent a common and significant clinical problem. In this study, a triphasic ceramic (calcium silicate, hydroxyapatite and tricalcium phosphate)-coated hydroxyapatite (HASi) having the benefits of both HA (osteointegration, osteoconduction) and silica (degradation) was used as a bone substitute for the repair of segmental defect (2 cm) created in a goat femur model. Three experimental goat femur implant groups--(a) bare HASi, (b) osteogenic-induced goat bone marrow-derived mesenchymal stem cells cultured HASi (HASi+C) and (c) osteogenic-induced goat bone marrow-derived mesenchymal stem cells cultured HASi+platelet-rich plasma (HASi+CP)--were designed and efficacy performance in the healing of the defect was evaluated. In all the groups, the material united with host bone without any inflammation and an osseous callus formed around the implant. This reflects the osteoconductivity of HASi where the cells have migrated from the cut ends of host bone. The most observable difference between the groups appeared in the mid region of the defect. In bare HASi groups, numerous osteoblast-like cells could be seen together with a portion of material. However, in HASi+C and HASi+CP, about 60-70% of that area was occupied by woven bone, in line with material degradation. The interconnected porous nature (50-500 microm), together with the chemical composition of the HASi, facilitated the degradation of HASi, thereby opening up void spaces for cellular ingrowth and bone regeneration. The combination of HASi with cells and PRP was an added advantage that could promote the expression of many osteoinductive proteins, leading to faster bone regeneration and material degradation. Based on these results, we conclude that bare HASi can aid in bone regeneration but, with the combination of cells and PRP, the sequence of healing events are much faster in large segmental bone defects in weight-bearing areas in goats.
Lomaglio, Melanie; Canale, Bob
2017-06-01
Acute bilateral foot drop is rare and may be due to peripheral or central lesions. The purpose of this case report was to describe the differential diagnosis and recovery of a patient with low back pain (LBP) that awoke with bilateral foot drop. A 39-year-old man with a history of LBP awoke with a steppage gait pattern. Spinal imaging and tapping were negative for sinister pathologies. A subsequent history taken by the physical therapist uncovered that the patient had previously taken a narcotic and slept in a kneeling position to relieve his LBP. Strength and sensory testing revealed isolated impairments in the fibular nerve distribution, and bilateral fibular palsy was suspected and later confirmed with electrophysiological studies. Surgical fibular nerve decompression was performed, and the patient underwent physical therapy. Five months later the patient demonstrated antigravity strength and a partial return of sensation. By 17 months, his Lower Extremity Functional Scale had improved from 17/80 to 78/80, revealing a near complete recovery. The patient's history of LBP was a "red herring" that delayed the diagnosis and caused undue stress to the patient. This case stresses the importance of a thorough history and clinical examination.
Hsu, Ying; Kim, Gunhee; Zhang, Qihong; Datta, Poppy; Seo, Seongjin
2017-01-01
Genetic mutations disrupting the structure and function of primary cilia cause various inherited retinal diseases in humans. Bardet-Biedl syndrome (BBS) is a genetically heterogeneous, pleiotropic ciliopathy characterized by retinal degeneration, obesity, postaxial polydactyly, intellectual disability, and genital and renal abnormalities. To gain insight into the mechanisms of retinal degeneration in BBS, we developed a congenital knockout mouse of Bbs8, as well as conditional mouse models in which function of the BBSome (a protein complex that mediates ciliary trafficking) can be temporally inactivated or restored. We demonstrate that BBS mutant mice have defects in retinal outer segment morphogenesis. We further demonstrate that removal of Bbs8 in adult mice affects photoreceptor function and disrupts the structural integrity of the outer segment. Notably, using a mouse model in which a gene trap inhibiting Bbs8 gene expression can be removed by an inducible FLP recombinase, we show that when BBS8 is restored in immature retinas with malformed outer segments, outer segment extension can resume normally and malformed outer segment discs are displaced distally by normal outer segment structures. Over time, the retinas of the rescued mice become morphologically and functionally normal, indicating that there is a window of plasticity when initial retinal outer segment morphogenesis defects can be ameliorated. PMID:29049287
Sur, Yoo Joon; Morsy, Mohamed; Mohan, Anita T; Zhu, Lin; Lachman, Nirusha; Saint-Cyr, Michel
2016-03-01
Although the perforating branches of the deep femoral artery have been introduced as recipient vessels for vascularized fibular grafts in the treatment of osteonecrosis of the femoral head, comprehensive knowledge of the related anatomy is deficient. The aims of this study were to provide detailed anatomical data for the perforating branches of the deep femoral artery and validate their usefulness as recipient vessels for vascularized fibular grafts. Anatomical dissection was performed on 11 fresh human cadaveric lower extremities. The number, locations, and diameters of the perforating branches were documented. The topographic relationships with the vastus ridge and the tendinous insertion of the gluteus maximus were clarified. The diameters of the perforating branches were compared with those of the ascending branch of the lateral circumflex femoral and the peroneal arteries. The mean number of perforating branches was 3.5. The mean distances from the vastus ridge to the first, second, and third perforating branches were 8.1, 13.7, and 20.4 cm, respectively. The first perforating branch was always located medial to the tendinous insertion of the gluteus maximus, whereas the second perforating branch was always located distal to the gluteus maximus. The mean diameters of the first, second, third, and fourth perforating branches were 3.1, 2.3, 1.6, and 1.2 mm, respectively. The mean diameters of the ascending branch of the lateral circumflex femoral and the peroneal arteries were 2.0 and 3.6 mm, respectively. The first perforating branch of the deep femoral artery is an appropriate alternative recipient vessel for vascularized fibular grafts in the treatment of osteonecrosis of the femoral head. It has a very consistent anatomy with a suitable location and diameter for anastomosis of the peroneal artery. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Anatomy and classification of the posterior tibial fragment in ankle fractures.
Bartoníček, Jan; Rammelt, Stefan; Kostlivý, Karel; Vaněček, Václav; Klika, Daniel; Trešl, Ivo
2015-04-01
The aim of this study was to analyze the pathoanatomy of the posterior fragment on the basis of a comprehensive CT examination, including 3D reconstructions, in a large patient cohort. One hundred and forty one consecutive individuals with an ankle fracture or fracture-dislocation of types Weber B or Weber C and evidence of a posterior tibial fragment in standard radiographs were included in the study. The mean patient age was 49 years (range 19-83 years). The exclusion criteria were patients below 18 years of age, inability to provide written consent, fractures of the tibial pilon, posttraumatic arthritis and pre-existing deformities. In all patients, post-injury radiographs were obtained in anteroposterior, mortise and lateral views. All patients underwent CT scanning in transverse, sagittal and frontal planes. 3D CT reconstruction was performed in 91 patients. We were able to classify 137 cases into one of the following four types with constant pathoanatomic features: type 1: extraincisural fragment with an intact fibular notch, type 2: posterolateral fragment extending into the fibular notch, type 3: posteromedial two-part fragment involving the medial malleolus, type 4: large posterolateral triangular fragment. In the 4 cases it was not possible to classify the type of the posterior tibial fragment. These were collectively termed type 5 (irregular, osteoporotic fragments). It is impossible to assess the shape and size of the posterior malleolar fragment, involvement of the fibular notch, or the medial malleolus, on the basis of plain radiographs. The system that we propose for classification of fractures of the posterior malleolus is based on CT examination and takes into account the size, shape and location of the fragment, stability of the tibio-talar joint and the integrity of the fibular notch. It may be a useful indication for surgery and defining the most useful approach to these injuries.
Ettinger, Kyle S; Alexander, Amy E; Arce, Kevin
2018-04-10
Virtual surgical planning (VSP), computer-aided design and computer-aided modeling, and 3-dimensional printing are 3 distinct technologies that have become increasingly used in head and neck oncology and microvascular reconstruction. Although each of these technologies has long been used for treatment planning in other surgical disciplines, such as craniofacial surgery, trauma surgery, temporomandibular joint surgery, and orthognathic surgery, its widespread use in head and neck reconstructive surgery remains a much more recent event. In response to the growing trend of VSP being used for the planning of fibular free flaps in head and neck reconstruction, some surgeons have questioned the technology's implementation based on its inadequacy in addressing other reconstructive considerations beyond hard tissue anatomy. Detractors of VSP for head and neck reconstruction highlight its lack of capability in accounting for multiple reconstructive factors, such as recipient vessel selection, vascular pedicle reach, need for dead space obliteration, and skin paddle perforator location. It is with this premise in mind that the authors report on a straightforward technique for anatomically localizing peroneal artery perforators during VSP for osteocutaneous fibular free flaps in which bone and a soft tissue skin paddle are required for ablative reconstruction. The technique allows for anatomic perforator localization during the VSP session based solely on data existent at preoperative computed tomographic angiography (CTA); it does not require any modifications to preoperative clinical workflows. It is the authors' presumption that many surgeons in the field are unaware of this planning capability within the context of modern VSP for head and neck reconstruction. The primary purpose of this report is to introduce and further familiarize surgeons with the technique of CTA perforator localization as a method of improving intraoperative fidelity for VSP of osteocutaneous fibular free flaps. Copyright © 2018. Published by Elsevier Inc.
Zhang, Yumin; Wang, Jianru; Wang, Jue; Niu, Xiaojun; Liu, Jianchun; Gao, Lan; Zhai, Xiaoyan; Chu, Kaibo
2015-12-01
Bone substitutes are used in wide range of orthopaedic application. An ideal bone substitute should exhibit superior osteoinductive and osteoconductive properties. Neither bio-derived materials nor synthetic materials can meet the needs of an ideal bone substitute. Preparation of composite materials is a promising way to improve properties of biomaterial. In this study, the porous poly lactic acid (PLA)/demineralized bone matrix (DBM) composite biomaterials prepared by supercritical CO2 technique were implanted to repair rabbit radius segmental bone defect. By comparing with PLA and bone autograft, the X-ray result and histological analysis showed the repair effect of PLA/DBM porous composite materials is significantly better than that of the PLA group and the blank control group, and is similar to autologous bone. The PLA/DBM can promote the healing of bone defects and can be used as a kind of ideal alternative materials to repair bone defects.
Management of segmental bony defects: the role of osteoconductive orthobiologics.
McKee, Michael D
2006-01-01
Our knowledge about, and the availability of, orthobiologic materials has increased exponentially in the last decade. Although previously confined to the experimental or animal-model realm, several orthobiologics have been shown to be useful in a variety of clinical situations. As surgical techniques in vascular anastomosis, soft-tissue coverage, limb salvage, and fracture stabilization have improved, the size and frequency of bony defects (commensurate with the severity of the initial injury) have increased, as well. Because all methods of managing segmental bony defects have drawbacks, a need remains for a readily available, void-filling, inexpensive bone substitute. Such a bone substitute fulfills a permissive role in allowing new bone to grow into a given defect. Such potential osteoconductive materials include ceramics, calcium sulfate or calcium phosphate compounds, hydroxyapatite, deproteinized bone, corals, and recently developed polymers. Some materials that have osteoinductive properties, such as demineralized bone matrix, also display prominent osteoconductive properties.
Tracheal reconstruction with autogenous jejunal microsurgical transfer.
Jones, R E; Morgan, R F; Marcella, K L; Mills, S E; Kron, I L
1986-06-01
Tracheal defects due to stricture formation, tracheomalacia, and neoplasms can present difficult reconstructive problems. Tracheal defects were surgically created in 6 dogs and primarily reconstructed with microsurgical free tissue transfer of autogenous jejunal segments. Primary healing was accomplished in all dogs without severe air leakage or infection. Bronchoscopy demonstrated no substantial secretions or tracheal narrowing. Gross pathological examination of the trachea revealed no evidence of tracheal disruption or infection. Direct measurements revealed no major tracheal narrowing. Microscopic examination demonstrated normal jejunal mucosa with a minimal amount of inflammatory change at the margins of the reconstruction at 6 weeks. Microvascular free tissue transfer of jejunal segments to correct cervical tracheal defects can readily be accomplished with excellent healing and maintenance of the tracheal lumen in dogs.
Baksi, D D; Pal, A K; Baksi, D P
2016-01-01
Background: Ununited femoral neck fracture is seen commonly in developing countries due to delayed presentation or failure of primary internal fixation. Such fractures, commonly present with partial or total absorption of femoral neck, osteonecrosis of femoral head in 8–30% cases with upward migration of trochanter posing problem for osteosynthesis, especially in younger individuals. Several techniques for treatment of such conditions are described like osteotomies or nonvascularied cortical or cancellous bone grafting provided varying degrees of success in terms of fracture union but unsatisfactory long term results occurred due to varying incidence of avascular necrosis (AVN) of femoral head. Moreover, in presence of AVN of femoral head neither free fibular graft nor cancellous bone graft is satisfactory. The vascularied bone grafting by deep circumflex iliac artery based on iliac crest bone grafting, free vascularied fibular grafting and muscle pedicle periosteal grafting showed high incidence of success rate. Osteosynthesis is the preferred treatment of choice in ununited femoral neck fracture in younger individuals. Materials and Methods: Of the 293 patients operated during the period from June 1977 to June 2009, 42 were lost to followup. Seven patients with gluteus medius muscle pedicle bone grafting (MPBG) were excluded. Thus, out of 244 patients, 208 (85.3%) untreated nonunion and 36 (14.7%) following failure of primary internal fixation were available for studies. Time interval between the date of injury and operation in untreated nonunion cases was mean 6.5 months and in failed internal fixation cases was mean 11.2 months. Ages of the patients varied from 16 to 55 years. Seventy patients had partial and 174 had subtotal absorption of the femoral neck. Evidence of avascular necrosis (AVN) femoral head was found histologically in 135 (54.3%) and radiologically in 48 (19.7%) patients. The patients were operated by open reduction of fracture, cannulated hip screw fixation, iliac crest bone chips and quadratus femoris MPBG. Results: The mean followup is 12.5 years (range 3-35). The union of fractures occurred in 202 (82.8%), delayed union in 18 (7.3%), and established nonunion in 24 (9.8%) patients. Full weight bearing was permitted at 16–22 weeks after union of fractures. Mean Harris hip score at the longest followup was 85.5. Among the complications, superficial wound infection occurred in 20 (8.2%), deep infection in seven (2.9%), and coxa vara in 39 (16%) patients. Preoperative radiodensity of femoral head disappeared mostly after the union of fracture whereas fresh radiodensity of femoral head appeared in 20 (8%) patients; nine (45%) of them developed segmental collapse. Conclusion: Ununited femoral neck fractureis characterized by absorption of femoral neck, posterior cortical defect, smoothening and overriding of fracture surfaces with intervening fibrous tissues associated with or without AVN of femoral head. The above method of osteosynthesis rectified the above pathology and provided satisfactory results with union of fractures in 90.1% patients at long term followup. PMID:27512217
"Palmar pivot flap" for resurfacing palmar lateral defects of the fingers.
Yam, Andrew; Peng, Yeong-Pin; Pho, Robert Wan-Heng
2008-12-01
Soft tissue defects on the lateral borders of the digits are difficult to reconstruct using local or local-regional flaps. We describe a "palmar pivot flap" to resurface an adjacent defect on the palmar-lateral aspect of the digit. The surgical technique is described. This flap is an axial pattern flap based on the subcutaneous transverse branches of the digital artery. The flap is pivoted up to 90 degrees on the neurovascular bundle in its base, into an adjacent defect. The flap can be raised from either the proximal or the middle phalangeal segments. It can cover defects sited from the level of the proximal interphalangeal joint up to the fingertip. The donor defect is limited to the same digit and is covered with a full-thickness skin graft. We have used this flap on 3 patients with defects at the middle phalangeal segment, the distal interphalangeal joint, and the fingertip. All healed primarily. One patient had a mild flexion contracture of the proximal interphalangeal joint, whereas the other 2 had no complications. The patients with distal interphalangeal joint and fingertip defects had excellent sensation in the flap (2-point discrimination of 5-6 mm). The palmar pivot flap is useful for resurfacing otherwise difficult defects on the lateral borders of the digits around and distal to the proximal interphalangeal joint, including those at the fingertip. It provides sensate, glabrous skin. The donor defect is on the same digit and is well hidden, producing an aesthetic and functional reconstruction.
Khodzhaev, N S; Sobolev, N P; Mushkova, I A; Izmaylova, S B; Karimova, A N
The diversity of methodological approaches and lack of pathogenetically reasonable tactics for patients with combined ocular injuries became the basis for the development and systematization of surgical rehabilitation stages of patients, in whom post-traumatic cataract is combined with post-traumatic aniridia and corneal scarring. to construct a visual rehabilitation approach to patients with post-traumatic defects of the anterior eye segment following optical-reconstructive surgery that involved implantation of an iris-lens diaphragm (ILD). We have analyzed 80 reconstructive cases with ILD implantation in patients with post-traumatic aniridia and corneal damage. These patients constituted the first study group (Group 1). We have also investigated 58 eyes with residual ametropy and stable visual function 1 year after ILD implantation before and after conducting a laser keratorefractive surgery. These patients were assigned to the second study group (Group 2). Rehabilitation approach to patients after anterior segment injuries that has been proposed allows to achieve high clinical and functional results and reduce the risk of intra- and postoperative complications. The proposed approach to patients after optical-reconstructive surgery with iris-lens diaphragm implantation followed by keratorefractive surgery is an effective method of visual rehabilitation of anterior eye segment post-traumatic defects.
Adjustable stiffness, external fixator for the rat femur osteotomy and segmental bone defect models.
Glatt, Vaida; Matthys, Romano
2014-10-09
The mechanical environment around the healing of broken bone is very important as it determines the way the fracture will heal. Over the past decade there has been great clinical interest in improving bone healing by altering the mechanical environment through the fixation stability around the lesion. One constraint of preclinical animal research in this area is the lack of experimental control over the local mechanical environment within a large segmental defect as well as osteotomies as they heal. In this paper we report on the design and use of an external fixator to study the healing of large segmental bone defects or osteotomies. This device not only allows for controlled axial stiffness on the bone lesion as it heals, but it also enables the change of stiffness during the healing process in vivo. The conducted experiments have shown that the fixators were able to maintain a 5 mm femoral defect gap in rats in vivo during unrestricted cage activity for at least 8 weeks. Likewise, we observed no distortion or infections, including pin infections during the entire healing period. These results demonstrate that our newly developed external fixator was able to achieve reproducible and standardized stabilization, and the alteration of the mechanical environment of in vivo rat large bone defects and various size osteotomies. This confirms that the external fixation device is well suited for preclinical research investigations using a rat model in the field of bone regeneration and repair.
Usher syndrome type 1–associated cadherins shape the photoreceptor outer segment
Parain, Karine; Aghaie, Asadollah; Picaud, Serge
2017-01-01
Usher syndrome type 1 (USH1) causes combined hearing and sight defects, but how mutations in USH1 genes lead to retinal dystrophy in patients remains elusive. The USH1 protein complex is associated with calyceal processes, which are microvilli of unknown function surrounding the base of the photoreceptor outer segment. We show that in Xenopus tropicalis, these processes are connected to the outer-segment membrane by links composed of protocadherin-15 (USH1F protein). Protocadherin-15 deficiency, obtained by a knockdown approach, leads to impaired photoreceptor function and abnormally shaped photoreceptor outer segments. Rod basal outer disks displayed excessive outgrowth, and cone outer segments were curved, with lamellae of heterogeneous sizes, defects also observed upon knockdown of Cdh23, encoding cadherin-23 (USH1D protein). The calyceal processes were virtually absent in cones and displayed markedly reduced F-actin content in rods, suggesting that protocadherin-15–containing links are essential for their development and/or maintenance. We propose that calyceal processes, together with their associated links, control the sizing of rod disks and cone lamellae throughout their daily renewal. PMID:28495838
Usher syndrome type 1-associated cadherins shape the photoreceptor outer segment.
Schietroma, Cataldo; Parain, Karine; Estivalet, Amrit; Aghaie, Asadollah; Boutet de Monvel, Jacques; Picaud, Serge; Sahel, José-Alain; Perron, Muriel; El-Amraoui, Aziz; Petit, Christine
2017-06-05
Usher syndrome type 1 (USH1) causes combined hearing and sight defects, but how mutations in USH1 genes lead to retinal dystrophy in patients remains elusive. The USH1 protein complex is associated with calyceal processes, which are microvilli of unknown function surrounding the base of the photoreceptor outer segment. We show that in Xenopus tropicalis , these processes are connected to the outer-segment membrane by links composed of protocadherin-15 (USH1F protein). Protocadherin-15 deficiency, obtained by a knockdown approach, leads to impaired photoreceptor function and abnormally shaped photoreceptor outer segments. Rod basal outer disks displayed excessive outgrowth, and cone outer segments were curved, with lamellae of heterogeneous sizes, defects also observed upon knockdown of Cdh23 , encoding cadherin-23 (USH1D protein). The calyceal processes were virtually absent in cones and displayed markedly reduced F-actin content in rods, suggesting that protocadherin-15-containing links are essential for their development and/or maintenance. We propose that calyceal processes, together with their associated links, control the sizing of rod disks and cone lamellae throughout their daily renewal. © 2017 Schietroma et al.
Segmental liver incarceration through a recurrent incisional lumbar hernia.
Salemis, Nikolaos S; Nisotakis, Konstantinos; Gourgiotis, Stavros; Tsohataridis, Efstathios
2007-08-01
Lumbar hernia is a rare congenital or acquired defect of the posterior abdominal wall. The acquired type is more common and occurs mainly as an incisional defect after flank surgery. Incarceration or strangulation of hernia contents is uncommon. Segmental liver incarceration through a recurrent incisional lumbar defect was diagnosed in a 58 years old woman by magnetic resonance imaging. The patient underwent an open repair of the complicated hernia. An expanded polytetraflouoroethylene (e-PTFE) mesh was fashioned as a sublay prosthesis. She had an uncomplicated postoperative course. Follow-up examinations revealed no evidence of recurrence. Although lumbar hernia rarely results in incarceration or strangulation, early repair is necessary because of the risks of complications and the increasing difficulty in repairment as it enlarges. Surgical repair is often difficult and challenging.
A Generic Deep-Learning-Based Approach for Automated Surface Inspection.
Ren, Ruoxu; Hung, Terence; Tan, Kay Chen
2018-03-01
Automated surface inspection (ASI) is a challenging task in industry, as collecting training dataset is usually costly and related methods are highly dataset-dependent. In this paper, a generic approach that requires small training data for ASI is proposed. First, this approach builds classifier on the features of image patches, where the features are transferred from a pretrained deep learning network. Next, pixel-wise prediction is obtained by convolving the trained classifier over input image. An experiment on three public and one industrial data set is carried out. The experiment involves two tasks: 1) image classification and 2) defect segmentation. The results of proposed algorithm are compared against several best benchmarks in literature. In the classification tasks, the proposed method improves accuracy by 0.66%-25.50%. In the segmentation tasks, the proposed method reduces error escape rates by 6.00%-19.00% in three defect types and improves accuracies by 2.29%-9.86% in all seven defect types. In addition, the proposed method achieves 0.0% error escape rate in the segmentation task of industrial data.
[Implantation of an Artificial Iris in 11 Patients].
Kniestedt, C; Eberhard, R; Fleischhauer, J
2016-04-01
Background. Iris defects are mostly acquired after injury, or may be iatrogenic after surgical excision of iris tumours or the result of collateral trauma after anterior segment surgery. They cause severe visual disability, e.g. glare, loss of contrast sensitivity, and loss of best corrected visual acuity. The foldable Koch iris prosthesis has a customised iris design and may be used to reconstruct the anterior segment in patients with partial or complete aniridia. History and Signs. We present the surgical management and clinical course of 6 patients with traumatic iris defects, together with 3 patients with partial aniridia after cataract surgery. Cataract surgery and implantation of an artificial iris were performed in 2 female patients (3 eyes) with congenital aniridia syndrome. Therapy and Outcome. No patient exhibited complications in the postoperative course, with the exception of various intraocular pressure peaks due to secondary glaucoma, that were all corrected by medication to lower topical pressure. Conclusions. In patients with major iris defects, the artificial iris allows functionally and aesthetically satisfactory reconstruction of the anterior segment. Georg Thieme Verlag KG Stuttgart · New York.
Problems with Excessive Residual Lower Leg Length in Pediatric Amputees
Osebold, William R; Lester, Edward L; Christenson, Donald M
2001-01-01
We studied six pediatric amputees with long below-knee residual limbs, in order to delineate their functional and prosthetic situations, specifically in relation to problems with fitting for dynamic-response prosthetic feet. Three patients had congenital pseudoarthrosis of the tibia secondary to neurofibromatosis, one had fibular hemimelia, one had a traumatic amputation, and one had amputation secondary to burns. Five patients had Syme's amputations, one had a Boyd amputation. Ages at amputation ranged from nine months to five years (average age 3 years 1 month). After amputation, the long residual below-knee limbs allowed fitting with only the lowest-profile prostheses, such as deflection plates. In three patients, the femoral dome to tibial plafond length was greater on the amputated side than on the normal side. To allow room for more dynamic-response (and larger) foot prostheses, two patients have undergone proximal and distal tibial-fibular epiphyseodeses (one at age 5 years 10 months, the other at 3 years 7 months) and one had a proximal tibial-fibular epiphyseodesis at age 7 years 10 months. (All three patients are still skeletally immature.) The families of two other patients are considering epiphyseodeses, and one patient is not a candidate (skeletally mature). Scanogram data indicate that at skeletal maturity the epiphyseodesed patients will have adequate length distal to their residual limbs to fit larger and more dynamic-response prosthetic feet. PMID:11813953
Damage Tolerance of Large Shell Structures
NASA Technical Reports Server (NTRS)
Minnetyan, L.; Chamis, C. C.
1999-01-01
Progressive damage and fracture of large shell structures is investigated. A computer model is used for the assessment of structural response, progressive fracture resistance, and defect/damage tolerance characteristics. Critical locations of a stiffened conical shell segment are identified. Defective and defect-free computer models are simulated to evaluate structural damage/defect tolerance. Safe pressurization levels are assessed for the retention of structural integrity at the presence of damage/ defects. Damage initiation, growth, accumulation, and propagation to fracture are included in the simulations. Damage propagation and burst pressures for defective and defect-free shells are compared to evaluate damage tolerance. Design implications with regard to defect and damage tolerance of a large steel pressure vessel are examined.
2016-01-01
This study was performed to quantitatively analyze medical knowledge of, and experience with, decision-making in preoperative virtual planning of mandibular reconstruction. Three shape descriptors were designed to evaluate local differences between reconstructed mandibles and patients’ original mandibles. We targeted an asymmetrical, wide range of cutting areas including the mandibular sidepiece, and defined a unique three-dimensional coordinate system for each mandibular image. The generalized algorithms for computing the shape descriptors were integrated into interactive planning software, where the user can refine the preoperative plan using the spatial map of the local shape distance as a visual guide. A retrospective study was conducted with two oral surgeons and two dental technicians using the developed software. The obtained 120 reconstruction plans show that the participants preferred a moderate shape distance rather than optimization to the smallest. We observed that a visually plausible shape could be obtained when considering specific anatomical features (e.g., mental foramen. mandibular midline). The proposed descriptors can be used to multilaterally evaluate reconstruction plans and systematically learn surgical procedures. PMID:27583465
Molecular dynamics simulations of fluoropolymers in the solid state
NASA Astrophysics Data System (ADS)
Holt, David Bryan
1998-10-01
Molecular mechanics and dynamics simulations have been utilized to address the behavior of helix reversal defects in fluoropolymers. The results of the simulations confirm that helix reversals do form and migrate in PTFE crystals. The most important defect structure is a helix reversal band: two helix reversals which bracker a small chain segment (typically 6-7 backbone atoms) having the opposite helical sense from the parent molecule. Small reversal bands had velocities ranging between 100 m/s (low temperature)-250 m/s (high temperature). The size of this reversal band defect is dependent upon the helical conformation and is equal to approximately half of the helical repeat unit in the low and intermediate temperature phases. In the high temperature phase where intermolecular effects are diminished, a wider distribution of reversal band sizes was observed during the simulations. A mechanism is identified by which significant reorientation of a chain segment about the molecular axis can occur when it is bracketed by two helix reversal bands. Simulations with a model containing a perfluoromethyl (PFM) group at low temperature showed that the presence of the PFM group significantly restricts chain mobility locally. However, a significant reduction in the helix reversal defect density was observed on neighboring chains as well. During simulations in which a shear deformation was applied to the models with and without a PFM group, an increase in reversal defect density was observed. However, the helix reversal density in the sheared model containing the PFM branch was less than that in the model without a PFM branch under no shear. These data implicate helix reversal defects and associated chain segment motions in the mechanical behavior of fluoropolymer materials.
Thrombus formation in the interrupted segment of the aorta.
Karavelioğlu, Yusuf; Kalçık, Macit; Yetim, Mucahit; Doğan, Tolga; Gölbaşı, Zehra
2017-06-01
Interrupted aorta is a very rare heart defect in which there is a gap between the ascending and the descending thoracic aorta. It is usually associated with other cardiac anomalies, including ventricular septal defect, ductus arteriosus, and truncus arteriosus. Severe cases present with serious complications such as hypertension, heart failure, or intracranial hemorrhage. Neurological complications are very rare form of presentation and commonly associated with intracranial aneurysms. We have reported a case of interrupted aorta who presented with transient ischemic attack due to thrombus formation in the interrupted segment of the aorta. © 2017, Wiley Periodicals, Inc.
LaPrade, Robert F; O'Brien, Luke; Kennedy, Nicholas I; Cinque, Mark E; Chahla, Jorge
2017-01-01
Numerous outcome studies regarding anterior cruciate ligament (ACL) reconstruction demonstrate the ability of athletes to return to a high level of play. However, to our knowledge, there is limited literature regarding return to play following injury to both the ACL and the fibular collateral ligament (FCL). We describe the case of a National Basketball Association (NBA) player who sustained a combined ACL and FCL knee injury and subsequently underwent surgical reconstruction of both affected ligaments. He was able to return to a preinjury level of competition at 9 months postoperatively. It is possible for athletes to return to competitive basketball and maintain a high production level following a single-staged reconstruction of both the ACL and the FCL.
Fragasso, G; Chierchia, S L; Landoni, C; Lucignani, G; Rossetti, E; Sciammarella, M; Vanoli, G E; Fazio, F
1998-07-01
We studied the relationship between coronary anatomy, perfusion and metabolism in myocardial segments exhibiting transient and persistent perfusion defects on stress/rest 99Tcm-MIBI single photon emission tomography in 35 patients (31 males, 4 females, mean age 56 +/- 7 years) with a previous myocardial infarction. Quantitative coronary angiography and assessment of myocardial perfusion reserve and glucose metabolism were performed within 1 week of one another. Perfusion was assessed by SPET after the intravenous injection of 740 MBq of 99Tcm-MIBI at rest and after exercise. Regional myocardial glucose metabolism was assessed by position emission tomography at rest (200 MBq of 18F-2-deoxyglucose, FDG) after an overnight fast with no glucose loading. All 35 patients exhibited persistent perfusion defects consistent with the clinically identified infarct site, and 27 (77%) also showed various degrees of within-infarct FDG uptake; 11 patients developed exercise-induced transient perfusion defects within, or in the vicinity of, 15 infarct segments and resting FDG uptake was present in 10 of these segments (67%). Five patients also showed exercise-induced transient perfusion defects in nine segments remote from the site of infarct: resting FDG uptake was present in six of these regions (67%). Finally, nine patients had increased glucose uptake in non-infarcted regions not showing transient perfusion defects upon exercise testing and perfused by coronary arteries with only minor irregularities. Our results confirm the presence of viable tissue in a large proportion of infarct sites. Moreover, FDG uptake can be seen in regions perfused by coronary arteries showing minor irregularities, not necessarily resulting in detectable transient perfusion defects on a MIBI stress scan. Since the clinical significance of such findings is not clear, further studies should be conducted to assess the long-term evolution of perfusion, function and metabolism in non-revascularized patients of those remote areas which are apparently normally perfused, but show abnormal fasting FDG uptake after myocardial infarction. Such studies may have important implications for the management of post-infarct patients, as the preservation of coronary vasodilator reserve and myocardial metabolism in remote myocardium may be seen as an additional goal in the treatment of such patients.
NASA Astrophysics Data System (ADS)
Anastasieva, E. A.; Voropaeva, A. A.; Sadovoy, M. A.; Kirilova, I. A.
2017-09-01
The problem of large bone defects replacement, formed after segmental bone resections, remains an actual issue of modern orthopedics. It is known that the autograft is the most acceptable material for the replacement of bone tissue; however, due to its small volume and physical properties, it has limited usage. Our goal is to analyze the results of the experiments and studies on replacement of large bone defects after resection of the bone tumor. The problem is justified by the complicated osteoconduction and osteointegration; because it is proved that the reconstruction of the microcirculatory bloodstream is difficult in the presence of damage more than 4 cm2. It was revealed that using of allograft in combination with additional components is comparable in effectiveness, including long-term period, with autograft usage. It is promising to combine plastic allogenous material, capable of reconstructing defects of various configuration intraoperatively, with the necessary chemotherapy with controlled desorption to maintain effective concentration of drug.
Wood industrial application for quality control using image processing
NASA Astrophysics Data System (ADS)
Ferreira, M. J. O.; Neves, J. A. C.
1994-11-01
This paper describes an application of image processing for the furniture industry. It uses an input data, images acquired directly from wood planks where defects were previously marked by an operator. A set of image processing algorithms separates and codes each defect and detects a polygonal approach of the line representing them. For such a purpose we developed a pattern classification algorithm and a new technique of segmenting defects by carving the convex hull of the binary shape representing each isolated defect.
Inorganic-organic shape memory polymers and foams for bone defect repairs
NASA Astrophysics Data System (ADS)
Zhang, Dawei
The ultimate goal of this research was to develop a "self-fitting" shape memory polymer (SMP) scaffold for the repair of craniomaxillofacial (CMF) bone defects. CMF defects may be caused by trauma, tumor removal or congenital abnormalities and represent a major class of bone defects. Their repair with autografts is limited by availability, donor site morbidity and complex surgical procedures. In addition, shaping and positioning of these rigid grafts into irregular defects is difficult. Herein, we have developed SMP scaffolds which soften at T > ˜56 °C, allowing them to conformally fit into a bone defect. Upon cooling to body temperature, the scaffold becomes rigid and mechanically locks in place. This research was comprised of four major studies. In the first study, photocrosslinkable acrylated (AcO) SMP macromers containing a poly(epsilon-caprolactone) (PCL) segment and polydimethylsiloxane (PDMS) segments were synthesized with the general formula: AcO-PCL40-block-PDMS m-block-PCL40-OAc. By varying the PDMS segment length (m), solid SMPs with highly tunable mechanical properties and excellent shape memory abilities were prepared. In the second study, porous SMP scaffolds were fabricated based on AcO-PCL 40-block-PDMS37-block-PCL 40-OAc via a revised solvent casting particulate leaching (SCPL) method. By tailoring scaffold parameters including salt fusion, macromer concentration and salt size, scaffold properties (e.g. pore features, compressive modulus and shape memory behavior) were tuned. In the third study, porous SMP scaffolds were produced from macromers with variable PDMS segment lengths (m = 0 -- 130) via an optimized SCPL method. The impact on pore features, thermal, mechanical, and shape memory properties as well as degradation rates were investigated. In the final study, a bioactive polydopamine coating was applied onto pore surfaces of the SMP scaffold prepared from PCL diacrylate. The thin coating did not affect intrinsic bulk properties of the scaffold. However, the coating significantly increased its bioactivity, giving rise to the formation of "bone-bonding" hydroxyapatite (HAp) when exposed to simulated body fluid (SBF). It was also shown that the coating largely enhanced the scaffold's capacities to support osteoblasts adhesion, proliferation and osteogenesis. Thus, the polydopamine coating should enhance the performance of the "self-fitting" SMP scaffolds for the repair of bone defects.
Perforator Peroneal Artery Flap for Tongue Reconstruction.
Chauhan, Shubhra; Chavre, Sachin; Chandrashekar, Naveen Hedne; B S, Naveen
2017-03-01
Reconstruction has evolved long way from primary closure to flaps. As time evolved, better understanding of vascularity of flap has led to the development of innovative reconstructive techniques. These flaps can be raised from various parts of the body for reconstruction and have shown least donor site morbidity. We use one such peroneal artery perforator flap for tongue reconstruction with advantage of thin pliable flap, minimal donor site morbidity and hidden scar. Our patient 57yrs old lady underwent wide local excision with selective neck dissection. Perforators are marked about 10 and 15 cm inferiorly from the fibular head using hand held Doppler. Leg is positioned in such a way to give better exposure during dissection of the flap and flap is harvested under a tourniquet with pressure kept 350 mm Hg. The perforator is kept at the eccentric location, so as to gain length of the pedicle. Skin incison is placed over the peroneal muscle and deepened unto the deep facia, then the dissection is continued over the muscle and the perforator arising from the lateral septum. The proximal perforator about 10 cm from the fibular head is a constant perforator and bigger one, which is traced up to the peroneal vessel. We could get a 6 cm of pedicle length. Finally the flap is islanded on this perforator and the pedicle is ligated and flap harvested. Anastamosis was done to the ipsilateral side to facial vessels. The donor site is closed primarily and in the upper half one can harvest 5 cm width flap without requiring a skin graft along with a length of 8 to 12 cm. Various local and free flap has been used for reconstruction of partial tongue defects with its obvious donor site problems, like less pliable skin and not so adequate tissue from local flaps and sacrificing a important artery as in radial forearm flap serves as the work horse in reconstruction of partial tongue defects, Concept of super microsurgery was popularized by Japanese in 1980s and the concept of angiosome proposed by Taylor paved the way for development of new flaps. True perforator flaps are those where the source vessel is left undisturbed and overlying skin flap is raised. Yoshimura proposed cutaneous flap could be raised from peroneal artery (Br J Plast Surg 42:715-718, 1989). Wolff et al. (Plast Reconstr Surg 113:107-113, 2004) first used perforator based peroneal artery flap for oral reconstruction. Location of perforators vary, hence pre operative localisation can be done by ultrasound doppler, CT angio or MR angiography. Disadvantages over radial flap include varying anatomic location of perforators, need for imaging and difficult dissection of delicate vessels through muscles and hence a learning curve. Our patient had an arterial thrombus within few hours post-operatively which was successfully salvaged with immediate re-exploration and re-anastomosis of artery. Post-operative healing was uneventful and donor site was closed primarily without the need for graft. Perforator peroneal flap serves as a useful armamentarium for reconstruction of moderate size defects of tongue, buccal mucosa and floor of mouth with advantages of thin pliable flap, minimal donor site morbidity and hidden scar.
Mitsukawa, Nobuyuki; Saiga, Atsuomi; Morishita, Tadashi; Satoh, Kaneshige
2014-07-01
Patients with bilateral cleft lips and palates have premaxillary protrusion and characteristic jaw deformities involving three-dimensional malposition of the premaxilla and bilateral maxillary bone segments. This study examined patients with bilateral cleft lips and palates who had deviation and hypoplasia of the premaxillas and bilateral maxillary segments. Before bone grafting, the patients were treated with special distraction performed separately for each bone segment using a halo-type external device. This report describes this novel treatment method which produced good results. The subjects were five patients with severe jaw deformities due to bilateral cleft lip and palate. They were treated with maxillary Le Fort I osteotomy and subsequent distraction performed separately for each bone segment using a halo device. In three of five patients, premaxillary osteotomy was not performed, and osteotomy and distraction were performed only for the right and left lateral segments with severe hypoplasia. All patients achieved distraction close to the desired amount. The widths of the alveolar clefts were narrowed, and satisfactory occlusion and maxillary arch form were achieved. After the surgery, three of five patients underwent bone grafting for bilateral alveolar cleft defects and the bone graft survival was satisfactory. This method had many benefits, including narrowing of alveolar clefts, improvement of maxillary hypoplasia, and achievement of a good maxillary arch form. In addition, subsequent bone grafting for alveolar cleft defects was beneficial, dental prostheses were unnecessary, and frequency of surgery and surgical invasiveness were reduced. This method is a good surgical procedure that should be considered for patients with bilateral cleft lips and palates who have premaxillary protrusion and hypoplasia of the right and left lateral segments. Copyright © 2013 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Cipitria, Amaia; Boettcher, Kathrin; Schoenhals, Sophia; Garske, Daniela S; Schmidt-Bleek, Katharina; Ellinghaus, Agnes; Dienelt, Anke; Peters, Anja; Mehta, Manav; Madl, Christopher M; Huebsch, Nathaniel; Mooney, David J; Duda, Georg N
2017-09-15
In-situ tissue regeneration aims to utilize the body's endogenous healing capacity through the recruitment of host stem or progenitor cells to an injury site. Stromal cell-derived factor-1α (SDF-1α) is widely discussed as a potent chemoattractant. Here we use a cell-free biomaterial-based approach to (i) deliver SDF-1α for the recruitment of endogenous bone marrow-derived stromal cells (BMSC) into a critical-sized segmental femoral defect in rats and to (ii) induce hydrogel stiffness-mediated osteogenic differentiation in-vivo. Ionically crosslinked alginate hydrogels with a stiffness optimized for osteogenic differentiation were used. Fast-degrading porogens were incorporated to impart a macroporous architecture that facilitates host cell invasion. Endogenous cell recruitment to the defect site was successfully triggered through the controlled release of SDF-1α. A trend for increased bone volume fraction (BV/TV) and a significantly higher bone mineral density (BMD) were observed for gels loaded with SDF-1α, compared to empty gels at two weeks. A trend was also observed, albeit not statistically significant, towards matrix stiffness influencing BV/TV and BMD at two weeks. However, over a six week time-frame, these effects were insufficient for bone bridging of a segmental femoral defect. While mechanical cues combined with ex-vivo cell encapsulation have been shown to have an effect in the regeneration of less demanding in-vivo models, such as cranial defects of nude rats, they are not sufficient for a SDF-1α mediated in-situ regeneration approach in segmental femoral defects of immunocompetent rats, suggesting that additional osteogenic cues may also be required. Stromal cell-derived factor-1α (SDF-1α) is a chemoattractant used to recruit host cells for tissue regeneration. The concept that matrix stiffness can direct mesenchymal stromal cell (MSC) differentiation into various lineages was described a decade ago using in-vitro experiments. Recently, alginate hydrogels with an optimized stiffness and ex-vivo encapsulated MSCs were shown to have an effect in the regeneration of skull defects of nude rats. Here, we apply this material system, loaded with SDF-1α and without encapsulated MSCs, to (i) recruit endogenous cells and (ii) induce stiffness-mediated osteogenic differentiation in-vivo, using as model system a load-bearing femoral defect in immunocompetent rats. While a cell-free approach is of great interest from a translational perspective, the current limitations are described. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Chou, Ying-Chao; Lee, Demei; Chang, Tzu-Min; Hsu, Yung-Heng; Yu, Yi-Hsun; Liu, Shih-Jung; Ueng, Steve Wen-Neng
2016-04-20
This study aimed to develop a new biodegradable polymeric cage to convert corticocancellous bone chips into a structured strut graft for treating segmental bone defects. A total of 24 adult New Zealand white rabbits underwent a left femoral segmental bone defect creation. Twelve rabbits in group A underwent three-dimensional (3D) printed cage insertion, corticocancellous chips implantation, and Kirschner-wire (K-wire) fixation, while the other 12 rabbits in group B received bone chips implantation and K-wire fixation only. All rabbits received a one-week activity assessment and the initial image study at postoperative 1 week. The final image study was repeated at postoperative 12 or 24 weeks before the rabbit scarification procedure on schedule. After the animals were sacrificed, both femurs of all the rabbits were prepared for leg length ratios and 3-point bending tests. The rabbits in group A showed an increase of activities during the first week postoperatively and decreased anterior cortical disruptions in the postoperative image assessments. Additionally, higher leg length ratios and 3-point bending strengths demonstrated improved final bony ingrowths within the bone defects for rabbits in group A. In conclusion, through this bone graft converting technique, orthopedic surgeons can treat segmental bone defects by using bone chips but with imitate characters of structured cortical bone graft.
Chou, Ying-Chao; Lee, Demei; Chang, Tzu-Min; Hsu, Yung-Heng; Yu, Yi-Hsun; Liu, Shih-Jung; Ueng, Steve Wen-Neng
2016-01-01
This study aimed to develop a new biodegradable polymeric cage to convert corticocancellous bone chips into a structured strut graft for treating segmental bone defects. A total of 24 adult New Zealand white rabbits underwent a left femoral segmental bone defect creation. Twelve rabbits in group A underwent three-dimensional (3D) printed cage insertion, corticocancellous chips implantation, and Kirschner-wire (K-wire) fixation, while the other 12 rabbits in group B received bone chips implantation and K-wire fixation only. All rabbits received a one-week activity assessment and the initial image study at postoperative 1 week. The final image study was repeated at postoperative 12 or 24 weeks before the rabbit scarification procedure on schedule. After the animals were sacrificed, both femurs of all the rabbits were prepared for leg length ratios and 3-point bending tests. The rabbits in group A showed an increase of activities during the first week postoperatively and decreased anterior cortical disruptions in the postoperative image assessments. Additionally, higher leg length ratios and 3-point bending strengths demonstrated improved final bony ingrowths within the bone defects for rabbits in group A. In conclusion, through this bone graft converting technique, orthopedic surgeons can treat segmental bone defects by using bone chips but with imitate characters of structured cortical bone graft. PMID:27104525
Ismail, Ahmed M; Rayan, Mona; Adel, Amr; Demerdash, Salah; Atef, Mohamed; Abdallah, Mohamed; Nammas, Wail
2014-02-01
We explored the prevalence and pattern of abnormal myocardial perfusion in patients with isolated coronary artery ectasia (CAE), as demonstrated by (99m)Tc-sestamibi scintigraphy. Prospectively, we enrolled 35 patients with angiographically documented CAE and no significant coronary obstruction, who underwent elective coronary angiography. Patients underwent Stress-rest (99m)Tc-sestamibi scintigraphy within 4 days of coronary angiography. They were divided into 2 groups: group I: with normal perfusion scan; and group II: with reversible perfusion defects. The mean age was 49.6 ± 6.9 years; 34 (97.1 %) were males. Seventy-nine (75.2 %) arteries were affected by CAE. Among 79 arteries affected by CAE, affection was diffuse in 37 (46.8 %). Thirteen (37.1 %) patients had normal perfusion scan (group I), whereas 22 (62.9 %) had reversible perfusion defects (group II). Among 22 patients with reversible perfusion defects, 20 (90.9 %) had mild and 2 (9.1 %) had moderate ischemia. Among 49 myocardial segments with reversible perfusion defects, 22 (44.9 %) were basal, 18 (36.7 %) mid-, and 9 (18.4 %) apical segments. Diffuse CAE was significantly more prevalent in group II versus group I, in all 3 major coronary arteries (p < 0.05 for all). In patients with isolated CAE who underwent elective coronary angiography, reversible perfusion defects demonstrated by (99m)Tc-sestamibi scintigraphy were rather prevalent, mostly mild, more likely to affect the basal and mid-segments of the myocardium, and more frequently associated with diffuse ectasia.
Bansal, Ankur; Sinha, Rahul Janak; Jhanwar, Ankur; Prakash, Gaurav; Purkait, Bimalesh; Singh, Vishwajeet
2017-01-01
Objective The incidence of ureteral stricture is showing a rising trend due to increased use of laparoscopic and upper urinary tract endoscopic procedures. Boari flap is the preferred method of repairing long- segment ureteral defects of 8–12 cm. The procedure has undergone change from classical open (transperitoneal and retroperitoneal) method to laparoscopic surgery and recently robotic surgery. Laparoscopic approach is cosmetically appealing, less morbid and with shorter hospital stay. In this case series, we report our experience of performing laparoscopic ureteral reimplantation with Boari flap in 3 patients. Material and methods This prospective study was conducted between January 2011 December 2014. The patients with a long- segment ureteral defect who had undergone laparoscopic Boari flap reconstruction were included in the study. Outcome of laparoscopic ureteral reimplantation with Boari flap for the manangement of long segment ureteral defect was evaluated. Results The procedure was performed on 3 patients, and male to female ratio was 1:2. One patient had bilateral and other two patient had left ureteral stricture. The mean length of ureteral stricture was 8.6 cm (range 8.2–9.2 cm). The mean operative time was 206 min (190 to 220 min). The average estimated blood loss was 100 mL (range 90–110 mL) and mean hospital stay was 6 days (range 5 to 7 days). The mean follow up was 19 months (range 17–22 months). None of the patients experienced any complication related to the procedure in perioperative period. Conclusion Laparoscopic ureteral reimplantation with Boari flap is safe, feasible and has excellent long term results. However, the procedure is technically challenging, requires extensive experience of intracorporeal suturing. PMID:28861304
Bansal, Ankur; Sinha, Rahul Janak; Jhanwar, Ankur; Prakash, Gaurav; Purkait, Bimalesh; Singh, Vishwajeet
2017-09-01
The incidence of ureteral stricture is showing a rising trend due to increased use of laparoscopic and upper urinary tract endoscopic procedures. Boari flap is the preferred method of repairing long- segment ureteral defects of 8-12 cm. The procedure has undergone change from classical open (transperitoneal and retroperitoneal) method to laparoscopic surgery and recently robotic surgery. Laparoscopic approach is cosmetically appealing, less morbid and with shorter hospital stay. In this case series, we report our experience of performing laparoscopic ureteral reimplantation with Boari flap in 3 patients. This prospective study was conducted between January 2011 December 2014. The patients with a long- segment ureteral defect who had undergone laparoscopic Boari flap reconstruction were included in the study. Outcome of laparoscopic ureteral reimplantation with Boari flap for the manangement of long segment ureteral defect was evaluated. The procedure was performed on 3 patients, and male to female ratio was 1:2. One patient had bilateral and other two patient had left ureteral stricture. The mean length of ureteral stricture was 8.6 cm (range 8.2-9.2 cm). The mean operative time was 206 min (190 to 220 min). The average estimated blood loss was 100 mL (range 90-110 mL) and mean hospital stay was 6 days (range 5 to 7 days). The mean follow up was 19 months (range 17-22 months). None of the patients experienced any complication related to the procedure in perioperative period. Laparoscopic ureteral reimplantation with Boari flap is safe, feasible and has excellent long term results. However, the procedure is technically challenging, requires extensive experience of intracorporeal suturing.
The treatment options for posterior malleolar fractures in tibial spiral fractures.
Guo, Jialiang; Liu, Lei; Yang, Zongyou; Hou, Zhiyong; Chen, Wei; Zhang, Yingze
2017-09-01
The posterior malleolar fracture (PMF) in tibial spiral fractures are a common type of complication that occurs in tibial fractures. However, the indication of fixation for posterior fractures is still under debate and varies between different surgeons'. It is not unusual to find the smaller PMF (<25%), which could be treated conservatively within guidelines, treated with internal fixation in clinic. The aim of this study is to evaluate the clinical outcomes of tibial spiral fractures with PMF and provide proper guidance for the treatment of this special fracture. A total of 284 cases of spiral fractures combined with PMF were collected and analyzed. Demographic data, fragment size (classified by 25% involvement of ankle joint), time to weight-bearing and functional scores post-operatively were recorded. The ankle-hindfoot scale of the American Orthopaedic Foot and Ankle Society (AOFAS), a visual analogue scale (VAS) pain score, assessment of dorsiflexion restriction and arthritis scale were used as the main evaluations. Forty patients with a larger PMF (≥25%) and 72 with smaller ones (<25%) were fixed and categorized as the fixation group (FG). In the nonfixation group (NG), the corresponding numbers were four and 168 patients respectively. A total of 279 PMF were classified as large posterolateral triangular fragment carrying the posterior half of the fibular notch and intra-incisural posterolateral fragment involving one-fourth to one-third of the fibular notch. However, no obvious differences were observed in terms of the clinical outcomes in PMF involving one-fourth to one-third of the fibular notch. In the treatment of smaller PMF (<25%) of this type, there were no obvious differences in the functional outcomes between fixed (SF) and nonfixed PMF (SN). Many patients with smaller PMFs were fixated, but functional outcomes of SF were not better than those of SN. There is no need to emphasize other factors guiding the treatment of PMF involving one-fourth to one-third of the fibular notch in spiral fractures. The traditional size of PMF may be only enough to guide the treatment of spiral fracture with PMF. But other types of PMF should still be treated considering morphology and fragment simultaneously.
Krettek, Christian; El Naga, Ashraf
2017-10-01
Segmental transport is an effective method of treatment for segmental defects, but the need for external fixation during the transport phase is a disadvantage. To avoid external fixation, we have developed a Cylinder-Kombi-Tube Segmental Transport (CKTST) module for combination with a commercially available motorized lengthening nail. This CKTST module allows for an all-internal segmental bone transport and also allows for optional lengthening if needed. The concept and surgical technique of CKTST are described and illustrated with a clinical case.
Fabric defect detection based on visual saliency using deep feature and low-rank recovery
NASA Astrophysics Data System (ADS)
Liu, Zhoufeng; Wang, Baorui; Li, Chunlei; Li, Bicao; Dong, Yan
2018-04-01
Fabric defect detection plays an important role in improving the quality of fabric product. In this paper, a novel fabric defect detection method based on visual saliency using deep feature and low-rank recovery was proposed. First, unsupervised training is carried out by the initial network parameters based on MNIST large datasets. The supervised fine-tuning of fabric image library based on Convolutional Neural Networks (CNNs) is implemented, and then more accurate deep neural network model is generated. Second, the fabric images are uniformly divided into the image block with the same size, then we extract their multi-layer deep features using the trained deep network. Thereafter, all the extracted features are concentrated into a feature matrix. Third, low-rank matrix recovery is adopted to divide the feature matrix into the low-rank matrix which indicates the background and the sparse matrix which indicates the salient defect. In the end, the iterative optimal threshold segmentation algorithm is utilized to segment the saliency maps generated by the sparse matrix to locate the fabric defect area. Experimental results demonstrate that the feature extracted by CNN is more suitable for characterizing the fabric texture than the traditional LBP, HOG and other hand-crafted features extraction method, and the proposed method can accurately detect the defect regions of various fabric defects, even for the image with complex texture.
Sebecić, B; Nikolić, V; Sikirić, P; Seiwerth, S; Sosa, T; Patrlj, L; Grabarević, Z; Rucman, R; Petek, M; Konjevoda, P; Jadrijević, S; Perović, D; Slaj, M
1999-03-01
Gastrectomy often results in increased likelihood of osteoporosis, metabolic aberration, and risk of fracture, and there is a need for a gastric peptide with osteogenic activity. A novel stomach pentadecapeptide, BPC-157, improves wound and fracture healing in rats in addition to having an angiogenic effect. Therefore, in the present study, using a segmental osteoperiosteal bone defect (0.8 cm, in the middle of the left radius) that remained incompletely healed in all control rabbits for 6 weeks (assessed in 2 week intervals), pentadecapeptide BPC-157 was further studied (either percutaneously given locally [10 microg/kg body weight] into the bone defect, or applied intramuscularly [intermittently, at postoperative days 7, 9, 14, and 16 at 10 microg/kg body weight] or continuously [once per day, postoperative days 7-21 at 10 microg or 10 ng/kg body weight]). For comparison, rabbits percutaneously received locally autologous bone marrow (2 mL, postoperative day 7). As standard treatment, immediately after its formation, the bone defect was filled with an autologous cortical graft. Saline-treated (2 mL intramuscularly [i.m.] and 2 mL locally into the bone defect), injured animals were used as controls. Pentadecapeptide BPC-157 significantly improved the healing of segmental bone defects. For instance, upon radiographic assessment, the callus surface, microphotodensitometry, quantitative histomorphometry (10 microg/kg body weight i.m. for 14 days), or quantitative histomorphometry (10 ng/kg body weight i.m. for 14 days) the effect of pentadecapeptide BPC-157 was shown to correspond to improvement after local application of bone marrow or autologous cortical graft. Moreover, a comparison of the number of animals with unhealed defects (all controls) or healed defects (complete bony continuity across the defect site) showed that besides pentadecapeptide intramuscular application for 14 days (i.e., local application of bone marrow or autologous cortical graft), also following other pentadecapeptide BPC-157 regimens (local application, or intermittent intramuscular administration), the number of animals with healed defect was increased. Hopefully, in the light of the suggested stomach significance for bone homeostasis, the possible relevance of this pentadecapeptide BPC-157 effect (local or intramuscular effectiveness, lack of unwanted effects) could be a basis for methods of choice in the future management of healing impairment in humans, and requires further investigation.
Gao, Bin; Li, Xiaoqing; Woo, Wai Lok; Tian, Gui Yun
2018-05-01
Thermographic inspection has been widely applied to non-destructive testing and evaluation with the capabilities of rapid, contactless, and large surface area detection. Image segmentation is considered essential for identifying and sizing defects. To attain a high-level performance, specific physics-based models that describe defects generation and enable the precise extraction of target region are of crucial importance. In this paper, an effective genetic first-order statistical image segmentation algorithm is proposed for quantitative crack detection. The proposed method automatically extracts valuable spatial-temporal patterns from unsupervised feature extraction algorithm and avoids a range of issues associated with human intervention in laborious manual selection of specific thermal video frames for processing. An internal genetic functionality is built into the proposed algorithm to automatically control the segmentation threshold to render enhanced accuracy in sizing the cracks. Eddy current pulsed thermography will be implemented as a platform to demonstrate surface crack detection. Experimental tests and comparisons have been conducted to verify the efficacy of the proposed method. In addition, a global quantitative assessment index F-score has been adopted to objectively evaluate the performance of different segmentation algorithms.
He, Fupo; Chen, Yan; Li, Jiyan; Lin, Bomiao; Ouyang, Yi; Yu, Bo; Xia, Yuanyou; Yu, Bo; Ye, Jiandong
2015-04-01
In this study, a platelet-rich plasma poly(lactic-co-glycolic acid) (PRP-PLGA)/calcium phosphate cement (CPC) composite scaffold was prepared by incorporating PRP into PLGA/CPC scaffold with unidirectional pore structure, which was fabricated by the unidirectional freeze casting of CPC slurry and the following infiltration of PLGA. The results from in vitro cell experiments and in vivo implantation in femoral defects manifested that incorporation of PRP into PLGA/CPC scaffold improved in vitro cell response (cell attachment, proliferation, and differentiation), and markedly boosted bone formation, angiogenesis and material degradation. The incorporation of PRP into scaffold showed more outstanding improvement in osteogenesis as the scaffolds were used to repair the segmental radial defects, especially at the early stage. The new bone tissues grew along the unidirectional lamellar pores of scaffold. At 12 weeks postimplantation, the segmental radial defects treated with PRP-PLGA/CPC scaffold had almost recuperated, whereas treated with the scaffold without PRP was far from healed. Taken together, the PRP-PLGA/CPC scaffold with unidirectional pore structure is a promising candidate to repair bone defects at various sites. © 2014 Wiley Periodicals, Inc.
Torque test measurement in segmental bone defects using porous calcium phosphate cement implants.
Kroese-Deutman, Henriette C; Wolke, Joop G C; Spauwen, Paul H M; Jansen, John A
2010-10-01
This study was performed to assess the bone healing supporting characteristics of porous calcium phosphate (Ca-P) cement when implanted in a rabbit segmental defect model as well as to determine the reliability of torque testing as a method to verify bone healing. The middiaphyseal radius was chosen as the area to create bilaterally increasing defect sizes (5, 10, and 15 mm), which were either filled with porous Ca-P cement or left open as a control. After 12 weeks of implantation, torque test measurements as well as histological and radiographic evaluation were performed. In two of the open 15 mm control defects, bone bridging was visible at the radiographic and histological evaluation. Bone was observed to be present in all porous Ca-P cement implants (5, 10, and 15 mm defects) after 12 weeks. No significant differences in torque measurements were observed between the 5 and 10 mm filled and open control defects using a t-test. In addition, the mechanical strength of all operated specimens was similar compared with nonoperated bone samples. The torsion data for the 15 mm open defect appeared to be lower compared with the filled 15 mm defect, but no significant difference could be proven. Within the limitation of the study design, porous Ca-P cement implants demonstrated osteoconductive properties and confirmed to be a suitable scaffold material in a weight-bearing situation. Further, the used torque testing method was found to be unreliable for testing the mechanical properties of the healed bone defect.
Güven, Melih; Tokyay, Abbas; Akman, Budak; Encan, Mehmet E; Altintaş, Faik
2016-03-01
The aim of this study was to report the experience with the use of a modified Grice-Green technique, which was performed using a partial subperiosteal fibular bone graft because of valgus unstable foot in children with cerebral palsy. Fifteen feet of 11 patients were evaluated on the basis of the appearance of the feet, clinical symptoms, and radiographic measurements. After an average follow-up duration of 24 (9-39) months, all feet showed satisfactory clinical and radiological results. Solid fusion and sustained correction took place in all feet. The gap at the donor site was bridged with new bone in all cases. No donor-site morbidity was detected. This modification of the Grice-Green technique can be used effectively in the correction of planovalgus foot in cerebral palsy.
Alves, Yanina; Ribeiro, Fernando; Silva, Anabela G
2017-07-05
Chronic ankle instability presents a high incidence and prevalence in basketbal players. It's important to develop strategies to reduce the functional and mechanical limitations resulting from this condition. To compare the effect of Mulligan ́s fibular repositioning taping with a placebo taping immediatly after application and after a running test (Yo-Yo IRT). 16 adult basketball players (10 male, 6 female) with chronic ankle instability and mean age 21.50 ± 2.76 years old. Assessment of static postural control (15 seconds of unipedal stance test with eyes closed in a force platform), functional performance (figure 8 hop test and lateral hop test) and neuromuscular control (peroneus longus latency time in sudden inversion) in two conditions: Mulligan and Placebo. No significant effect was found for the intervantion factor in both hop tests (p>0.170), but there was a significant effect for the time factor (p<0.03). For the peroneus longus latency time, there was a significant interaction between factors (p=0.028) and also for time (p=0.042). No significant effect was found for any of the static postural control variables (area, speed and total displacement) (p≥0.10). There was no differences between Mulligan's fibular repositioning taping and Placebo taping in postural control and functional performance in basketball players with chronic ankle instability. However, Mulligan's taping appears to reduce peroneus longus latency time after a running when compared with a placebo taping.
Jamshidi, Khodamorad; Mirkazemi, Masoud; Izanloo, Azra; Mirzaei, Alireza
2018-01-01
Several therapeutic strategies have been used for managing unicameral bone cyst (UBC) of the proximal femur. However, there is insufficient evidence to support one treatment over another, and the optimal treatment is controversial. This study aims at describing our experience with surgical reconstruction of paediatric UBCs of the proximal femur using a proximal locking plate and fibular strut allograft. In total, 14 consecutive paediatric patients with Dormans types IB (four cases) and IIB (10 cases) UBC were assessed. Mean patient age was 8.6 ± 2.3 years, and mean follow-up period was 41.7 ± 29.8 months. Six patients (42.8%) were referred with a pathologic fracture. Clinical/radiological outcome and complication rates were evaluated at the final follow-up session. No cysts were Capanna's class III (recurrence) or IV (no response). Complete healing (Capanna's class I) was seen in ten cysts, while four other cysts healed with residual radiolucent areas (Capanna's class II). Mean healing period was 14.1 ± 5.1 (9-24 months). One patient had superficial infection, one heterotopic ossification, and one mild coxa vara, and mean Musculoskeletal Tumor Society (MSTS) score was 99.5%. According to our results, locking plate and fibular strut graft in Dormans classification types IB and IIB results in a favorable outcome in managing UBC of the proximal femur in the paediatric population.
Morcillo Azcárate, J; Bernabeu-Wittel, J; Fernández-Pineda, I; Conejo-Mir, M D; Tuduri Limousin, I; Aspiazu Salinas, D A; de Agustín Asensio, J C
2010-04-01
PHACES syndrome associates a segmental facial hemangioma with cerebral malformations, aortic branches/cranial arteries anomalies, cardiac defects, eye anomalies or ventral wall defects. The aim of this study is to analyze our experience with this syndrome. Retrospective study of the cases seen at our unit in the last year. We treat 4 cases; 3 girls and 1 child. Besides the segmental hemangioma they presented: 3 vascular cerebral malformations; 2 structural cardiopathies; 2 cerebral malformations, 1 microftalmia. We did not find ventral wall defects. A case received treatment with two cycles of metilprednisolone i.v. and oral prednisone, with favourable course; two cases received initial treatment with oral prednisone continued of oral propanolol in rising pattern up to 2 mg/kg/day, Obtaining both the detention of the tumour growth and regression of the lesion, with very good tolerance. A 7-year-old patient has been treated with colouring pulse laser for her residual lesions. When we see a segmental facial hemangioma we must perform a wide diagnostic study in order to discard a PHACES syndrome. Multidisciplinar approach to the patient by a wide expert's group gets an earlier diagnose and improves the outcome. Propranolol is a promising therapeutic alternative.
Use of Adipose Derived Stem Cells to Treat Large Bone Defects. Addendum
2009-07-01
optimal delivery . We have also completed characterization of our segmental defect model, including analysis of vascular ingrowth during defect healing...cells seeded in 1.2% Keltone alginate at a density of 12-15x106cells/ml were loaded on 24-well transwell insert membranes [6]. Once hydrogel discs...process from tissue culture plates and hydrogels does not alter the surface phenotype. Gene expression of surface markers and proteins associated with
Structure Formation in Solutions of Rigid Polymers Undergoing a Phase Transition
1987-04-01
cyclohexene dioxide (ERL-4206) - 10 g. nonenyl succinic anhydride (NSA) - 26 g. dimethyl amino ethanol ( DMAE ) - 0.4 g. After infiltration, short segments...existence of a significant number of defects within the individual microfibril. The presence of defects in the lateral packing of PBT chains is also suggested...of the D- and L- enantiomers yields a nematic phase. The ordered phases exhi- bit complex textures due to defects (disclinations) which depend on
2016-12-01
gastrocnemius muscles. 4. Place an interlocking intramedullary nail using a custom spacer to maintain 5-cm defect length. 5. Place a pre-molded 5 cm long x...2 cm diameter PMMA spacer around the nail in the defect. 6. Irrigate the wound with normal (0.9 %) saline and close the wound. The Treatment...PMMA spacer using a “bomb bay door opening”. 4. Remove the spacer without damaging the membrane or nail . 5. Collect appropriate IM samples as
Cerebro-costo-mandibular Syndrome
McNicholl, B.; Egan-Mitchell, B.; Murray, J. P.; Doyle, J. F.; Kennedy, J. D.; Crome, L.
1970-01-01
Three sibs with a hitherto unreported syndrome are described, the main features being mental handicap, palatal defects, micrognathia, and severe costovertebral defects, involving segmentation of most ribs and fusion of their dorsal ends to the vertebral bodies. In addition one infant had hypoplasia of an elbow together with defects of sacrum and coccyx; she and one other sib had minor dental defects. The syndrome is potentially lethal in the neonatal period; one of the sibs has survived. The inheritance is probably autosomal recessive. ImagesFIG. 1FIG. 2FIG. 3FIG. 4 PMID:5427859
The influence of defects of the fatigue resistance of butt and girth welds in A106B steel
NASA Technical Reports Server (NTRS)
Leis, B. N.; Goetz, D. P.; Scott, P. M.
1986-01-01
This three-phase study was directed at developing a fitness for service defect acceptance criteria for welds with defect indications. The study focussed on A106 Gr. B steel pipe. The first phase involved a literature search and critical review to develop the preliminary acceptance criteria to the extent permitted by the data. The second phase developed data for flat plate, wall segment, and vessel specimens containing artificial or natural planar or volumetric defects. The final phase developed acceptance criteria from the test data.
Intensity compensation for on-line detection of defects on fruit
NASA Astrophysics Data System (ADS)
Wen, Zhiqing; Tao, Yang
1997-10-01
A machine-vision sorting system was developed that utilizes the difference in light reflectance of fruit surfaces to distinguish the defective and good apples. To accommodate to the spherical reflectance characteristics of fruit with curved surface like apple, a spherical transform algorithm was developed that converts the original image to a non-radiant image without losing defective segments on the fruit. To prevent high-quality dark-colored fruit form being classified into the defective class and increase the defect detection rate for light-colored fruit, an intensity compensation method using maximum propagation was used. Experimental results demonstrated the effectiveness of the method based on maximum propagation and spherical transform for on-line detection of defects on apples.
Wieding, Jan; Souffrant, Robert; Mittelmeier, Wolfram; Bader, Rainer
2013-04-01
Repairing large segmental defects in long bones caused by fracture, tumour or infection is still a challenging problem in orthopaedic surgery. Artificial materials, i.e. titanium and its alloys performed well in clinical applications, are plenary available, and can be manufactured in a wide range of scaffold designs. Although the mechanical properties are determined, studies about the biomechanical behaviour under physiological loading conditions are rare. The goal of our numerical study was to determine the suitability of open-porous titanium scaffolds to act as bone scaffolds. Hence, the mechanical stability of fourteen different scaffold designs was characterized under both axial compression and biomechanical loading within a large segmental distal femoral defect of 30mm. This defect was stabilized with an osteosynthesis plate and physiological hip reaction forces as well as additional muscle forces were implemented to the femoral bone. Material properties of titanium scaffolds were evaluated from experimental testing. Scaffold porosity was varied between 64 and 80%. Furthermore, the amount of material was reduced up to 50%. Uniaxial compression testing revealed a structural modulus for the scaffolds between 3.5GPa and 19.1GPa depending on porosity and material consumption. The biomechanical testing showed defect gap alterations between 0.03mm and 0.22mm for the applied scaffolds and 0.09mm for the intact bone. Our results revealed that minimizing the amount of material of the inner core has a smaller influence than increasing the porosity when the scaffolds are loaded under biomechanical loading. Furthermore, an advanced scaffold design was found acting similar as the intact bone. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.
Li, Jing; Qin, Yu; Zhao, Fang-Kun; Wu, Di; He, Xue-Fei; Liu, Jia; Zhao, Jiang-Yue; Zhang, Jin-Song
2016-01-01
To explore the molecular mechanisms in lens development and the pathogenesis of Peters anomaly in Smad4 defective mice. Le-Cre transgenic mouse line was employed to inactivate Smad4 in the surface ectoderm selectively. Pathological techniques were used to reveal the morphological changes of the anterior segment in Smad4 defective eye. Immunohistochemical staining was employed to observe the expression of E-cadherin, N-cadherin and α-SMA in anterior segment of Smad4 defective mice and control mice at embryonic (E) day 16.5. Real-time quantitative polymerase chain reaction (qPCR) was performed to detect the expression of Snail, Zeb1, Zeb2 and Twist2 in lens of Smad4 defective mice and control mice at E16.5. Statistical evaluations were performed using the unpaired Student's t-test (two-tailed) by SPSS 11.0 software. Conditional deletion of Smad4 on eye surface ectoderm resulted in corneal dysplasia, iridocorneal angle closure, corneolenticular adhesions and cataract resembling Peters anomaly. Loss of Smad4 function inhibited E-cadherin expression in the lens epithelium cells and corneal epithelium cells in Smad4 defective eye. Expression of N-cadherin was up-regulated in corneal epithelium and corneal stroma. Both E-cadherin and N-cadherin were down-regulated at the future trabecular meshwork region in mutant eye. The qPCR results showed that the expression of Twist2 was increased significantly in the mutant lens (P<0.01). Smad4 is essential to eye development and likely a candidate pathogenic gene to Peters anomaly by regulating epithelial-mesenchymal transition. Twist2 can be regulated by Smad4 and plays an essential role in lens development.
Ng, Min Hwei; Duski, Suryasmi; Tan, Kok Keong; Yusof, Mohd Reusmaazran; Low, Kiat Cheong; Mohamed Rose, Isa; Mohamed, Zahiah; Bin Saim, Aminuddin; Idrus, Ruszymah Bt Hj
2014-01-01
Calcium phosphate-based bone substitutes have not been used to repair load-bearing bone defects due to their weak mechanical property. In this study, we reevaluated the functional outcomes of combining ceramic block with osteogenic-induced mesenchymal stem cells and platelet-rich plasma (TEB) to repair critical-sized segmental tibial defect. Comparisons were made with fresh marrow-impregnated ceramic block (MIC) and partially demineralized allogeneic bone block (ALLO). Six New Zealand White female rabbits were used in each study group and three rabbits with no implants were used as negative controls. By Day 90, 4/6 rabbits in TEB group and 2/6 in ALLO and MIC groups resumed normal gait pattern. Union was achieved significantly faster in TEB group with a radiological score of 4.50 ± 0.78 versus ALLO (1.06 ± 0.32), MIC (1.28 ± 0.24), and negative controls (0). Histologically, TEB group scored the highest percentage of new bone (82% ± 5.1%) compared to ALLO (5% ± 2.5%) and MIC (26% ± 5.2%). Biomechanically, TEB-treated tibiae achieved the highest compressive strength (43.50 ± 12.72 MPa) compared to those treated with ALLO (15.15 ± 3.57 MPa) and MIC (23.28 ± 6.14 MPa). In conclusion, TEB can repair critical-sized segmental load-bearing bone defects and restore limb function. PMID:25165699
Yassine, Kalbaza Ahmed; Mokhtar, Benchohra; Houari, Hemida; Karim, Amara; Mohamed, Melizi
2017-01-01
Aim: Finding an ideal bone substitute to treat large bone defects, delayed union and nonunions remain a challenge for orthopedic surgeons and researchers. Several studies have been conducted on bone regeneration; each has its own advantages and disadvantages. The aim of this study was to evaluate the effect of a combination of hydroxyapatite (HA) powder with autologous bone marrow (BM) aspirate on the repair of segmental radial defect in a rabbit model. Materials and Methods: A total of 36 male and adult New Zealand rabbit with a mean weight of 2.25 kg were used in this study. Approximately, 5 mm defect was created in the mid-shaft of the radius to be filled with HA powder in the control group “HA” (n=18) and with a combination of HA powder and autologous BM aspirate in the test group “HA+BM” (n=18). Animals were observed daily for healing by inspection of the surgical site, and six rabbits of each group were sacrificed at 30, 60, and 90 post-operative days to perform a radiographic evaluation of defect site. Results: Obtained results revealed a better and more rapid bone regeneration in the test group: Since the defect was rapidly and completely filled with mature bone tissue after 90 days. Conclusion: Based on these findings, we could infer that adding a BM aspirate to HA is responsible of a better regeneration process leading to a complete filling of the defect. PMID:28831217
Internal Prosthetic Replacement of Skeletal Segments Lost in Combat Related Injuries.
1981-08-01
1-cm segment from the proximal third to prevent distraction of the fragments. The fiber metal segment is then placed in the appropriate defect and the...articularis genu suprema. The medial collateral ligament is sectioned through this incision and the medial meniscus removed in toto. The articular capsule...the image intensifier showed no evidence of motion. A physical therapy was instituted to mobilize and strengthen her knee. Case #11. This 52 year old
Yang, Lin; Liu, Hongjun; Zhang, Wenzhong; Song, Guoxun; Xia, Shicong; Zhang, Naichen; Gu, Jiaxiang; Yuan, Chaoqun
2017-10-01
To explore the effectiveness of modified anterolateral thigh perforator flap pedicled by cross-bridge microvascular anastomosis in treatment of soft tissue defects in the middle and lower segments of the leg. Between March 2011 and June 2015, 15 cases with skin and soft tissue defects in the middle and lower segments of the legs were treated. There were 9 males and 6 females, aged 22-48 years (mean, 32.6 years). Of whom, 8 patients caused by traffic accidents, 5 by machine twist, and 2 by crash injury of heavy object. The mean interval from injury to admission was 82.6 hours (range, 2 hours to 1 week). The area of defect ranged from 13 cm×9 cm to 23 cm×16 cm. After primary debridement and vaccum sealing drainage treatment, the defects were repaired with modified anterolateral thigh perforator flap pedicled by cross-bridge microvascular anastomosis. The size of flap ranged from 15 cm×10 cm to 25 cm×15 cm. The donor sites were sutured directly or repaired with the skin grafts. The pedicle division was done at 4 weeks after operation. After operation, venous crisis occurred in 1 case and distal skin necrosis in 2 cases which was healed by dressing change. The other tissue flaps survived successfully and wounds healed by first intention. All skin grafts at donor site survived after operation, and primary healing of wound was obtained. All patients were followed up 6-24 months (mean, 13 months). All flaps were characterized by soft texture, satisfactory appearance, and restoring the protective sensation. Moreover, the two-point discrimination ranged from 15 to 28 mm (mean, 19.5 mm) at 6 months after operation. The function of both lower extremities were normal without obvious contracture of scar at donor site. Modified free anterolateral thigh perforator flap, with little damage in donor site, a reliable blood supply by making a cross-bridge microvascular anastomosis with pretibial or posterior tibial blood vessel on normal leg, is a reliable alternative method for repairing soft tissue defects with the main vessels of serious injury in the middle and lower segments of the leg.
NASA Astrophysics Data System (ADS)
Castillo, Richard; Castillo, Edward; McCurdy, Matthew; Gomez, Daniel R.; Block, Alec M.; Bergsma, Derek; Joy, Sarah; Guerrero, Thomas
2012-04-01
To determine the spatial overlap agreement between four-dimensional computed tomography (4D CT) ventilation and single photon emission computed tomography (SPECT) perfusion hypo-functioning pulmonary defect regions in a patient population with malignant airway stenosis. Treatment planning 4D CT images were obtained retrospectively for ten lung cancer patients with radiographically demonstrated airway obstruction due to gross tumor volume. Each patient also received a SPECT perfusion study within one week of the planning 4D CT, and prior to the initiation of treatment. Deformable image registration was used to map corresponding lung tissue elements between the extreme component phase images, from which quantitative three-dimensional (3D) images representing the local pulmonary specific ventilation were constructed. Semi-automated segmentation of the percentile perfusion distribution was performed to identify regional defects distal to the known obstructing lesion. Semi-automated segmentation was similarly performed by multiple observers to delineate corresponding defect regions depicted on 4D CT ventilation. Normalized Dice similarity coefficient (NDSC) indices were determined for each observer between SPECT perfusion and 4D CT ventilation defect regions to assess spatial overlap agreement. Tidal volumes determined from 4D CT ventilation were evaluated versus measurements obtained from lung parenchyma segmentation. Linear regression resulted in a linear fit with slope = 1.01 (R2 = 0.99). Respective values for the average DSC, NDSC1 mm and NDSC2 mm for all cases and multiple observers were 0.78, 0.88 and 0.99, indicating that, on average, spatial overlap agreement between ventilation and perfusion defect regions was comparable to the threshold for agreement within 1-2 mm uncertainty. Corresponding coefficients of variation for all metrics were similarly in the range: 0.10%-19%. This study is the first to quantitatively assess 3D spatial overlap agreement between clinically acquired SPECT perfusion and specific ventilation from 4D CT. Results suggest high correlation between methods within the sub-population of lung cancer patients with malignant airway stenosis.
2011-04-01
tissue and polymer: mineralized tissue stained dark green, osteoid and collagen bright red, soft tissue pink to light green, and erythrocytes bright...of bone, soft tissue , and polymer, high-resolution digital images were acquired at 1.25 · or 20 · . The area of interest comprising the bone defect...bone, soft tissue , and polymer (when present) within the defect were quantified using Metamorph software (Molecular Devices, Inc.) and were calculated
Ankle and pantalar arthrodeses using vascularized fibular grafts.
Yajima, Hiroshi; Kobata, Yasunori; Tomita, Yasuharu; Kawate, Kenji; Sugimoto, Kazuya; Takakura, Yoshinori
2004-01-01
From 1989 to 1998 ankle and pantalar arthrodeses using vascularized fibular grafts were performed for seven patients. The indications for surgery were chronic nonunion following fracture of the distal tibia in four patients, rheumatoid arthritis in two, and talus necrosis in one. The ankle joint was fused in the two patients with a pilon fracture, and in the other five patients, both the ankle and subtalar joints were fused. In one patient, additional bone grafting was required for delayed union. In the other six patients, the mean period required to obtain radiographic bone union was 6 months (range, 4-9 months). The time until the patients could walk without braces ranged from 6 to 20 months (mean, 12.3 months). Local infection was not encountered in any patients. This procedure represents a viable option for patients in whom a standard, less complicated arthrodesis cannot be performed.
Hanken, Henning; Schablowsky, Clemens; Smeets, Ralf; Heiland, Max; Sehner, Susanne; Riecke, Björn; Nourwali, Ibrahim; Vorwig, Oliver; Gröbe, Alexander; Al-Dam, Ahmed
2015-04-01
The reconstruction of large facial bony defects using microvascular transplants requires extensive surgery to achieve full rehabilitation of form and function. The purpose of this study is to measure the agreement between virtual plans and the actual results of maxillofacial reconstruction. This retrospective cohort study included 30 subjects receiving maxillofacial reconstruction with a preoperative virtual planning. Parameters including defect size, position, angle and volume of the transplanted segments were compared between the virtual plan and the real outcome using paired t test. A total of 63 bone segments were transplanted. The mean differences between the virtual planning and the postoperative situation were for the defect sizes 1.17 mm (95 % confidence interval (CI) (-.21 to 2.56 mm); p = 0.094), for the resection planes 1.69 mm (95 % CI (1.26-2.11); p = 0.033) and 10.16° (95 % CI (8.36°-11.96°); p < 0.001) and for the planes of the donor segments 10.81° (95 % CI (9.44°-12.17°); p < 0.001) The orientation of the segments differed by 6.68° (95 % CI (5.7°-7.66°); p < 0.001) from the virtual plan; the length of the segments differed by -0.12 mm (95 % CI (0.89-0.65 mm); not significant (n.s.)), respectively, while the volume differed by 73.3 % (95 % CI (69.4-77.6 %); p < 0.001). The distance between the transplanted segments and the remaining bone was 1.49 mm (95 % CI (1.24-1.74); p < 0.001) and between the segments 1.49 mm (95 % CI (1.16-1.81); p < 0.001). Virtual plans for mandibular and maxillofacial reconstruction can be realised with excellent match. These highly satisfactory postoperative results are the basis for an optimal functional and aesthetic reconstruction in a single surgical procedure. The technique should be further investigated in larger study populations and should be further improved.
Fu, Chen Ju; Wong, Yon Cheong; Tsang, Yuk Ming; Wang, Li Jen; Chen, Huan Wu; Ku, Yi Kang; Wu, Cheng Hsien; Chen, Huan Wen; Kang, Shih Ching
2015-01-01
Intrahepatic portal vein injuries secondary to blunt abdominal trauma are difficult to diagnose and can result in insidious bleeding. We aimed to compare computed tomography arterial portography (CTAP), reperfusion CTAP (rCTAP), and conventional computed tomography (CT) for diagnosing portal vein injuries after blunt hepatic trauma. Patients with blunt hepatic trauma, who were eligible for nonoperative management, underwent CTAP, rCTAP, and CT. The number and size of perfusion defects observed using the three methods were compared. A total of 13 patients (seven males/six females) with a mean age of 34.5±14.1 years were included in the study. A total of 36 hepatic segments had perfusion defects on rCTAP and CT, while there were 47 hepatic segments with perfusion defects on CTAP. The size of perfusion defects on CT (239 cm3; interquartile range [IQR]: 129.5, 309.5) and rCTAP (238 cm3; IQR: 129.5, 310.5) were significantly smaller compared with CTAP (291 cm3; IQR: 136, 371) (both, P = 0.002). Perfusion defects measured by CTAP were significantly greater than those determined by either rCTAP or CT in cases of blunt hepatic trauma. This finding suggests that CTAP is superior to rCTAP and CT in evaluating portal vein injuries after blunt liver trauma.
7 CFR 51.1175 - Classification of defects.
Code of Federal Regulations, 2012 CFR
2012-01-01
... STANDARDS) United States Standards for Grades of Florida Oranges and Tangelos Definitions § 51.1175... segments more than 1/4 inch (6.4 mm) at stem end, or the equivalent of this amount, by volume, when occurring in other portions of the fruit Affecting all segments more than 1/2 inch (12.7 mm) at stem end, or...
7 CFR 51.1175 - Classification of defects.
Code of Federal Regulations, 2011 CFR
2011-01-01
... STANDARDS) United States Standards for Grades of Florida Oranges and Tangelos Definitions § 51.1175... segments more than 1/4 inch (6.4 mm) at stem end, or the equivalent of this amount, by volume, when occurring in other portions of the fruit Affecting all segments more than 1/2 inch (12.7 mm) at stem end, or...
7 CFR 51.1175 - Classification of defects.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Definitions § 51.1175 Classification of defects. Table I Factor Injury Damage Serious damage Very serious... mushy condition Affecting all segments more than 1/4 inch (6.4 mm) at stem end, or the equivalent of... 1/2 inch (12.7 mm) at stem end, or the equivalent of this amount, by volume, when occurring in other...
7 CFR 51.784 - Classification of defects.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Definitions § 51.784 Classification of defects. Table I Factor Injury Damage Serious damage Very serious.../4 inch (6.4 mm) at stem end, or the equivalent of this amount, by volume, when occurring in other portions of the fruit Affecting all segments more than 1/2 inch (12.7 mm) at stem end, or the equivalent of...
7 CFR 51.784 - Classification of defects.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Definitions § 51.784 Classification of defects. Table I Factor Injury Damage Serious damage Very serious.../4 inch (6.4 mm) at stem end, or the equivalent of this amount, by volume, when occurring in other portions of the fruit Affecting all segments more than 1/2 inch (12.7 mm) at stem end, or the equivalent of...
7 CFR 51.1175 - Classification of defects.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Definitions § 51.1175 Classification of defects. Table I Factor Injury Damage Serious damage Very serious... mushy condition Affecting all segments more than 1/4 inch (6.4 mm) at stem end, or the equivalent of... 1/2 inch (12.7 mm) at stem end, or the equivalent of this amount, by volume, when occurring in other...
2014-10-01
histology, and microCT analysis. In the current phase of work he will receive more specialized ` training and orientation to microCT analysis...fibrous connective tissue. • Performed histology on goat autogenous bone graft which demonstrated that the quantity and quality of cancellous bone graft
Kuroe, Kazuto; Iino, Shoichiro; Shomura, Kenji; Okubo, Akiro; Sugihara, Kazumasa; Ito, Gakuji
2003-05-01
Collapse of the maxillary minor segment with lateral crossbite is a common feature in patients with repaired unilateral cleft lip/palate because of maxillary alveolar bony defect and palatal scar tissue. Distraction osteogenesis (DOG) is an effective technique of lengthening and augmentation for bone and gingiva. This case report describes the effects of unilateral advancement of the maxillary minor segment by DOG in two patients with the repaired unilateral cleft lip/palate.
Changes in ankle joint motion after Supramalleolar osteotomy: a cadaveric model.
Kim, Hak Jun; Yeo, Eui Dong; Rhyu, Im Joo; Lee, Soon-Hyuck; Lee, Yeon Soo; Lee, Young Koo
2017-09-09
Malalignment of the ankle joint has been found after trauma, by neurological disorders, genetic predisposition and other unidentified factors, and results in asymmetrical joint loading. For a medial open wedge supramalleolar osteotomy(SMO), there are some debates as to whether concurrent fibular osteotomy should be performed. We assessed the changes in motion of ankle joint and plantar pressure after supramalleolar osteotomy without fibular osteotomy. Ten lower leg specimens below the knee were prepared from fresh-frozen human cadavers. They were harvested from five males (10 ankles)whose average age was 70 years. We assessed the motion of ankle joint as well as plantar pressure for SS(supra-syndesmotic) SMO and IS(intra-syndesmotic) SMO. After the osteotomy, each specimen was subjected to axial compression from 20 N preload to 350 N representing half-body weight. For the measurement of the motion of ankle joint, the changes in gap and point, angles in ankle joint were measured. The plantar pressure were also recorded using TekScan sensors. The changes in the various gap, point, and angles movements on SS-SMO and IS-SMO showed no statistically significant differences between the two groups. Regarding the shift of plantar center of force (COF) were noted in the anterolateral direction, but not statistically significant. SS-SMO and IS-SMO with intact fibula showed similar biomechanical effect on the ankle joint. We propose that IS-SMO should be considered carefully for the treatment of osteoarthrosis when fibular osteotomy is not performed because lateral cortex fracture was less likely using the intrasyndesmosis plane because of soft tissue support.
Maderbacher, Günther; Keshmiri, Armin; Zeman, Florian; Grifka, Joachim; Baier, Clemens
2015-11-01
Reconstructing the natural joint line in knee revision surgery improves clinical and functional outcome but may be challenging when both cartilage and bone were removed during previous operations. Assessing joint lines (JLs) by means of bony landmarks is inadvisable because of large variations in human anatomy. Because of the inherent symmetry of the human body, we hypothesised that JLs may be directly assessed by measuring the distances from the bony landmarks to the JL of the contralateral knee by means of radiographic images. Using scaled weight-bearing radiographs in anteroposterior view of both knees, two independent observers measured the distances from the fibular head, the medial and lateral epicondyle, and the adductor tubercle to the JL. A two-sided p value of ≤0.05 was considered statistically significant. Two hundred knees of 100 patients (50 men and 50 women) were examined. For the fibular head, the mean difference between the treated and the control knee was 0.0 mm with narrow confidence limits ranging from -1.1 to 1.1. As a new assessment method, we have suggested to assess the JL by means of radiographs of the contralateral knee. The most precise parameter was found to be the distance between the fibular head and the JL. The level of arthritis, age, gender, visibility of the landmarks, and misalignment did not influence measurement accuracy. This parameter is the first tibia-related landmark for assessing the JL, which advantageously corresponds to the tibia-first technique in revision surgery. Diagnostic Study, Level II.
Song, Kedong; Wang, Hai; Zhang, Bowen; Lim, Mayasari; Liu, Yingchao; Liu, Tianqing
2013-03-01
In this paper, two-dimensional flow field simulation was conducted to determine shear stresses and velocity profiles for bone tissue engineering in a rotating wall vessel bioreactor (RWVB). In addition, in vitro three-dimensional fabrication of tissue-engineered bones was carried out in optimized bioreactor conditions, and in vivo implantation using fabricated bones was performed for segmental bone defects of Zelanian rabbits. The distribution of dynamic pressure, total pressure, shear stress, and velocity within the culture chamber was calculated for different scaffold locations. According to the simulation results, the dynamic pressure, velocity, and shear stress around the surface of cell-scaffold construction periodically changed at different locations of the RWVB, which could result in periodical stress stimulation for fabricated tissue constructs. However, overall shear stresses were relatively low, and the fluid velocities were uniform in the bioreactor. Our in vitro experiments showed that the number of cells cultured in the RWVB was five times higher than those cultured in a T-flask. The tissue-engineered bones grew very well in the RWVB. This study demonstrates that stress stimulation in an RWVB can be beneficial for cell/bio-derived bone constructs fabricated in an RWVB, with an application for repairing segmental bone defects.
Ankle stress test for predicting the need for surgical fixation of isolated fibular fractures.
Egol, Kenneth A; Amirtharajah, Mohana; Amirtharage, Mohana; Tejwani, Nirmal C; Capla, Edward L; Koval, Kenneth J
2004-11-01
The purpose of this study was to confirm the prevalence of medial ankle widening among patients with an isolated fibular fracture and to determine the functional outcome of nonoperative treatment despite a diagnosis of a supination-external rotation stage-IV injury based on stress radiography. One hundred and one patients with evidence of an isolated fibular fracture and an intact mortise seen on a standard ankle trauma radiograph series were evaluated with stress radiographs. Clinical signs were recorded at the time of presentation. A positive stress test was defined as > or =4 mm of widening of the medial clear space. Patients with a negative stress test were treated nonoperatively, those with a positive stress test and clinical signs of medial injury were treated surgically, and those with a positive stress test and no signs of medial injury were treated according to the preference of the surgeon and patient. The patients were followed prospectively with radiographs and ankle outcome scores. Sixty-six (65%) of the 101 patients had a positive stress radiograph. Thirty-six of them had signs of medial injury, and thirty had no medial injury. With regard to predicting a positive stress radiograph, medial tenderness had a sensitivity of 56% and a specificity of 80%, swelling had a sensitivity of 55% and a specificity of 71%, and ecchymosis had a sensitivity of 26% and a specificity of 91%. Of the subset of patients without signs of medial injury, twenty were treated nonoperatively (group I) and ten were treated operatively (group II). Two of the twenty patients in group I had evidence of persistent widening of the medial clear space at the time of the latest follow-up (mean, 7.4 months); only one of those patients was symptomatic. The average American Orthopaedic Foot and Ankle Society (AOFAS) score was 94 points in group I and 93 points in group II. We found a high rate of positive stress radiographs for patients who presented with an isolated fibular fracture and an intact ankle mortise on the initial radiographs. Medial tenderness, swelling, and ecchymosis were not sensitive with regard to predicting widening of the medial clear space on stress radiographs. All of the patients with a positive stress radiograph and no clinical symptoms who were treated without surgery had a good or excellent clinical result.
Stevenson, J D; Doxey, R; Abudu, A; Parry, M; Evans, S; Peart, F; Jeys, L
2018-04-01
Aims Preserving growth following limb-salvage surgery of the upper limb in children remains a challenge. Vascularized autografts may provide rapid biological incorporation with the potential for growth and longevity. In this study, we aimed to describe the outcomes following proximal humeral reconstruction with a vascularized fibular epiphyseal transfer in children with a primary sarcoma of bone. We also aimed to quantify the hypertrophy of the graft and the annual growth, and to determine the functional outcomes of the neoglenofibular joint. Patients and Methods We retrospectively analyzed 11 patients who underwent this procedure for a primary bone tumour of the proximal humerus between 2004 and 2015. Six had Ewing's sarcoma and five had osteosarcoma. Their mean age at the time of surgery was five years (two to eight). The mean follow-up was 5.2 years (1 to 12.2). Results The overall survival at five and ten years was 91% (confidence interval (CI) 95% 75% to 100%). At the time of the final review, ten patients were alive. One with local recurrence and metastasis died one-year post-operatively. Complications included seven fractures, four transient nerve palsies, and two patients developed avascular necrosis of the graft. All the fractures presented within the first postoperative year and united with conservative management. One patient had two further operations for a slipped fibular epiphysis of the autograft, and a hemi-epiphysiodesis for lateral tibial physeal arrest. Hypertrophy and axial growth were evident in nine patients who did not have avascular necrosis of the graft. The mean hypertrophy index was 65% (55% to 82%), and the mean growth was 4.6 mm per annum (2.4 to 7.6) in these nine grafts. At final follow-up, the mean modified functional Musculoskeletal Tumour Society score was 77% (63% to 83%) and the mean Toronto Extremity Salvage Score (TESS) was 84% (65% to 94%). Conclusion Vascularized fibular epiphyseal transfer preserves function and growth in young children following excision of the proximal humerus for a malignant bone tumour. Function compares favourably to other limb-salvage procedures in children. Longer term analysis is required to determine if this technique proves to be durable into adulthood. Cite this article: Bone Joint J 2018;100-B:535-41.
Ge, Qihang; Wan, Chunyou; Liu, Yabei; Ji, Xu; Ma, Jihai; Cao, Haikun; Yong, Wei; Liu, Zhao; Zhang, Ningning
2017-08-01
To investigate the effect of axial stress stimulation on tibial and fibular open fractures healing after Taylor space stent fixation. The data of 45 cases with tibial and fibular open fractures treated by Taylor space stent fixation who meet the selection criteria between January 2015 and June 2016 were retrospectively analysed. The patients were divided into trial group (23 cases) and control group (22 cases) according to whether the axial stress stimulation was performed after operation. There was no significant difference in gender, age, affected side, cause of injury, type of fracture, and interval time from injury to operation between 2 groups ( P >0.05). The axial stress stimulation was performed in trial group after operation. The axial load sharing ratio was tested, and when the value was less than 10%, the external fixator was removed. The fracture healing time, full weight-bearing time, and external fixator removal time were recorded and compared. After 6 months of external fixator removal, the function of the limb was assessed by Johner-Wruhs criteria for evaluation of final effectiveness of treatment of tibial shaft fractures. There were 2 and 3 cases of needle foreign body reaction in trial group and control group, respectively, and healed after symptomatic anti allergic treatment. All the patients were followed up 8-12 months with an average of 10 months. All the fractures reached clinical healing, no complication such as delayed union, nonunion, or osteomyelitis occurred. The fracture healing time, full weight-bearing time, and external fixator removal time in trial group were significantly shorter than those in control group ( P <0.05). After 6 months of external fixator removal, the function of the limb was excellent in 13 cases, good in 6 cases, fair in 3 cases, and poor in 1 case in trial group, with an excellent and good rate of 82.6%; and was excellent in 5 cases, good in 10 cases, fair in 4 cases, and poor in 3 cases in control group, with an excellent and good rate of 68.2%, showing significant difference between 2 groups ( Z =-2.146, P =0.032). The axial stress stimulation of Taylor space stent fixation can promote the healing of tibial and fibular open fractures and promote local bone formation at fracture site.
Three-stage treatment protocol for recalcitrant distal femoral nonunion.
Ma, Ching-Hou; Chiu, Yen-Chun; Tu, Yuan-Kun; Yen, Cheng-Yo; Wu, Chin-Hsien
2017-04-01
In this study, we proposed a three-stage treatment protocol for recalcitrant distal femoral nonunion and aimed to analyze the clinical results. We retrospective reviewed 12 consecutive patients with recalcitrant distal femoral nonunion undergoing our three-stage treatment protocol from January 2010 to December 2014 in our institute. The three-stage treatment protocol comprised debridement of the nonunion site, lengthening to eliminate leg length discrepancy, deformity correction, stabilization with a locked plate, filling of the defect with cement spacer for inducing membrane formation, and bone reconstruction using a cancellous bone autograft (Masquelet technique) or free vascularized fibular bone graft. The bone union time, wound complication, lower limbs alignment, amount of lengthening, knee range of motion, and functional outcomes were evaluated. Osseous union with angular deformity <5° and leg length discrepancy <1 cm were achieved in all the patients. The average amount of lengthening was 5.88 cm (range 3.5-12 cm). Excellent or good outcomes were obtained in 9 patients. Although the current study involved only a small number of patients and the intervention comprised three stages, we believe that such a protocol may be a valuable alternative for the treatment of recalcitrant distal femoral nonunion.
Bone Marrow Aspirate Concentrate in Animal Long Bone Healing: An Analysis of Basic Science Evidence.
Gianakos, Arianna; Ni, Amelia; Zambrana, Lester; Kennedy, John G; Lane, Joseph M
2016-01-01
Long bone fractures that fail to heal or show a delay in healing can lead to increased morbidity. Bone marrow aspirate concentrate (BMAC) containing bone mesenchymal stem cells (BMSCs) has been suggested as an autologous biologic adjunct to aid long bone healing. The purpose of this study was to systematically review the basic science in vivo evidence for the use of BMAC with BMSCs in the treatment of segmental defects in animal long bones. The PubMed/MEDLINE and EMBASE databases were screened in July 14-25, 2014. The following search criteria were used: [("bmac" OR "bone marrow aspirate concentrate" OR "bmc" OR "bone marrow concentrate" OR "mesenchymal stem cells") AND ("bone" OR "osteogenesis" OR "fracture healing" OR "nonunion" OR "delayed union")]. Three authors extracted data and analyzed for trends. Quality of evidence score was given to each study. Results are presented as Hedge G standardized effect sizes with 95% confidence intervals. The search yielded 35 articles for inclusion. Of studies reporting statistics, 100% showed significant increase in bone formation in the BMAC group on radiograph. Ninety percent reported significant improvement in earlier bone healing on histologic/histomorphometric assessment. Eighty-one percent reported a significant increase in bone area on micro-computed tomography. Seventy-eight percent showed a higher torsional stiffness for the BMAC-treated defects. In the in vivo studies evaluated, BMAC confer beneficial effects on the healing of segmental defects in animal long bone models when compared with a control. Proof-of-concept has been established for BMAC in the treatment of animal segmental bone defects.
Shanti, Rabie M; Yampolsky, Andrew; Milles, Maano; Braidy, Hani
2015-11-01
The present report describes 2 patients who underwent mandibular reconstruction after segmental mandibulectomy for benign pathology. The potential of an ultrasonic-aided biodegradable system for containment of a nonvascularized bone graft is discussed. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Chen, Bin; Pei, Guo-xian; Wang, Ke; Jin, Dan; Wei, Kuan-hai; Ren, Gao-hong
2003-02-01
To study whether tissue engineered bone can repair the large segment bone defect of large animal or not. To observe what character the fascia flap played during the osteanagenesis and revascularization process of tissue engineered bone. 9 Chinese goats were made 2 cm left tibia diaphyseal defect. The repairing effect of the defects was evaluated by ECT, X-ray and histology. 27 goats were divided into three groups: group of CHAP, the defect was filled with coral hydroxyapatite (CHAP); group of tissue engineered bone, the defect was filled with CHAP + bone marrow stroma cells (BMSc); group of fascia flap, the defect was filled with CHAP + BMSc + fascia flap. After finished culturing and inducing the BMSc, CHAP of group of tissue engineered bone and of fascia flap was combined with it. Making fascia flap, different materials as described above were then implanted separately into the defects. Radionuclide bone imaging was used to monitor the revascularization of the implants at 2, 4, 8 weeks after operation. X-ray examination, optical density index of X-ray film, V-G staining of tissue slice of the implants were used at 4, 8, 12 weeks after operation, and the biomechanical character of the specimens were tested at 12 weeks post operation. In the first study, the defect showed no bone regeneration phenomenon. 2 cm tibia defect was an ideal animal model. In the second study, group of CHAP manifested a little trace of bone regeneration, as to group of tissue engineered bone, the defect was almost repaired totally. In group of fascia flap, with the assistance of fascia flap which gave more chance to making implants to get more nutrient, the repair was quite complete. The model of 2 cm caprine tibia diaphyseal defect cannot be repaired by goat itself and can satisfy the tissue engineering's demands. Tissue engineered bone had good ability to repair large segment tibia defect of goat. Fascia flap can accelerate the revascularization process of tissue engineered bone. And by this way, it augment the ability of tissue engineered bone to repair the large bone defect of goat.
Myocardial perfusion abnormalities in asymptomatic patients with systemic lupus erythematosus
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hosenpud, J.D.; Montanaro, A.; Hart, M.V.
1984-08-01
Accelerated coronary artery disease and myocardial infarction in young patients with systemic lupus erythematosus is well documented; however, the prevalence of coronary involvement is unknown. Accordingly, 26 patients with systemic lupus were selected irrespective of previous cardiac history to undergo exercise thallium-201 cardiac scintigraphy. Segmental perfusion abnormalities were present in 10 of the 26 studies (38.5 percent). Five patients had reversible defects suggesting ischemia, four patients had persistent defects consistent with scar, and one patient had both reversible and persistent defects in two areas. There was no correlation between positive thallium results and duration of disease, amount of corticosteroid treatment,more » major organ system involvement or age. Only a history of pericarditis appeared to be associated with positive thallium-201 results (p less than 0.05). It is concluded that segmental myocardial perfusion abnormalities are common in patients with systemic lupus erythematosus. Whether this reflects large-vessel coronary disease or small-vessel abnormalities remains to be determined.« less
Medical image segmentation based on SLIC superpixels model
NASA Astrophysics Data System (ADS)
Chen, Xiang-ting; Zhang, Fan; Zhang, Ruo-ya
2017-01-01
Medical imaging has been widely used in clinical practice. It is an important basis for medical experts to diagnose the disease. However, medical images have many unstable factors such as complex imaging mechanism, the target displacement will cause constructed defect and the partial volume effect will lead to error and equipment wear, which increases the complexity of subsequent image processing greatly. The segmentation algorithm which based on SLIC (Simple Linear Iterative Clustering, SLIC) superpixels is used to eliminate the influence of constructed defect and noise by means of the feature similarity in the preprocessing stage. At the same time, excellent clustering effect can reduce the complexity of the algorithm extremely, which provides an effective basis for the rapid diagnosis of experts.
Surgical repair of sciatic nerve traumatic rupture: technical considerations and approaches.
Abou-Al-Shaar, Hussam; Yoon, Nam; Mahan, Mark A
2018-01-01
Traumatic proximal sciatic nerve rupture poses surgical repair dilemmas. Disruption often causes a large nerve gap after proximal neuroma and distal scar removal. Also, autologous graft material to bridge the segmental defect may be insufficient, given the sciatic nerve diameter. The authors utilized knee flexion to allow single neurorrhaphy repair of a large sciatic nerve defect, bringing healthy proximal stump to healthy distal segment. To avoid aberrant regeneration, the authors split the sciatic nerve into common peroneal and tibial divisions. After 3 months, the patient can fully extend the knee and has evidence of distal regeneration and nerve continuity without substantial injury. The video can be found here: https://youtu.be/lsezRT5I8MU .
Context-based automated defect classification system using multiple morphological masks
Gleason, Shaun S.; Hunt, Martin A.; Sari-Sarraf, Hamed
2002-01-01
Automatic detection of defects during the fabrication of semiconductor wafers is largely automated, but the classification of those defects is still performed manually by technicians. This invention includes novel digital image analysis techniques that generate unique feature vector descriptions of semiconductor defects as well as classifiers that use these descriptions to automatically categorize the defects into one of a set of pre-defined classes. Feature extraction techniques based on multiple-focus images, multiple-defect mask images, and segmented semiconductor wafer images are used to create unique feature-based descriptions of the semiconductor defects. These feature-based defect descriptions are subsequently classified by a defect classifier into categories that depend on defect characteristics and defect contextual information, that is, the semiconductor process layer(s) with which the defect comes in contact. At the heart of the system is a knowledge database that stores and distributes historical semiconductor wafer and defect data to guide the feature extraction and classification processes. In summary, this invention takes as its input a set of images containing semiconductor defect information, and generates as its output a classification for the defect that describes not only the defect itself, but also the location of that defect with respect to the semiconductor process layers.
Raschke, M J; Mann, J W; Oedekoven, G; Claudi, B F
1992-09-01
The Ilizarov method of segmental bone transport has been shown to be an alternative to more conventional treatments of posttraumatic bony defects. After extensive clinical experience with the unreamed tibial nail in open fractures up to Grade IIIb, a new monorail fixation system for callus distraction and segmental bone transport was devised. This Monorail system is composed of an unreamed intramedullary (IM) nail and a unilateral AO distraction device. The new fixation method and the preliminary clinical experience are reported here. Four patients who previously sustained Grades II-IIIb open tibial fractures had an average bony defect of 9 cm. Two patients had previous bony infections. All patients had had serial debridements and myocutaneous flaps were required in three patients. An unreamed IM nail was inserted, and the transport device was applied. After an osteotomy, segmental transport was carried out until docking was achieved. The external fixator was removed after interlocking of the transported segment. The mean duration of external fixation was 17.9 days/cm and the mean period until roentgenographic consolidation of the distraction and nonunion site was 41.2 days/cm. There were two pin-tract infections but no IM infections. One nail broke after osseous consolidation of the regenerate at the distal interlocking site and required exchange. The goal of transport was achieved in all cases without angular or rotational deformity or length discrepancy. There were no neurovascular injuries.
Fu, Chen-Ju; Wong, Yon-Cheong; Tsang, Yuk-Ming; Wang, Li-Jen; Chen, Huan-Wu; Ku, Yi-Kang; Wu, Cheng-Hsien; Chen, Huan-Wen; Kang, Shih-Ching
2015-01-01
PURPOSE Intrahepatic portal vein injuries secondary to blunt abdominal trauma are difficult to diagnose and can result in insidious bleeding. We aimed to compare computed tomography arterial portography (CTAP), reperfusion CTAP (rCTAP), and conventional computed tomography (CT) for diagnosing portal vein injuries after blunt hepatic trauma. METHODS Patients with blunt hepatic trauma, who were eligible for nonoperative management, underwent CTAP, rCTAP, and CT. The number and size of perfusion defects observed using the three methods were compared. RESULTS A total of 13 patients (seven males/six females) with a mean age of 34.5±14.1 years were included in the study. A total of 36 hepatic segments had perfusion defects on rCTAP and CT, while there were 47 hepatic segments with perfusion defects on CTAP. The size of perfusion defects on CT (239 cm3; interquartile range [IQR]: 129.5, 309.5) and rCTAP (238 cm3; IQR: 129.5, 310.5) were significantly smaller compared with CTAP (291 cm3; IQR: 136, 371) (both, P = 0.002). CONCLUSION Perfusion defects measured by CTAP were significantly greater than those determined by either rCTAP or CT in cases of blunt hepatic trauma. This finding suggests that CTAP is superior to rCTAP and CT in evaluating portal vein injuries after blunt liver trauma. PMID:26268303
Akdemir, Ali; Sahin, Cagdas; Ari, Sabahattin Anil; Ergenoglu, Mete; Ulukus, Murat; Karadadas, Nedim
2018-01-01
To demonstrate a new technique of isthmocele repair via laparoscopic surgery. Case report (Canadian Task Force classification III). The local Ethics Committee waived the requirement for approval. Isthmocele localized at a low uterine segment is a defect of a previous caesarean scar due to poor myometrial healing after surgery [1]. This pouch accumulates menstrual bleeding, which can cause various disturbances and irregularities, including abnormal uterine bleeding, infertility, pelvic pain, and scar pregnancy [2-6]. Given the absence of a clearly defined surgical method in the literature, choosing the proper approach to treating isthmocele can be arduous. Laparoscopy provides a minimally invasive procedure in women with previous caesarean scar defects. A 28-year-old woman, gravida 2 para 2, presented with a complaint of prolonged postmenstrual bleeding for 5 years. She had undergone 2 cesarean deliveries. Transvaginal ultrasonography revealed a hypoechogenic area with menstrual blood in the anterior lower uterine segment. Magnetic resonance imaging showed an isthmocele localized at the anterior left lateral side of the uterus, with an estimated volume of approximately 12 cm 3 . After patient preparation, laparoscopy was performed. To repair the defect, the uterovesical peritoneal fold was incised and the bladder was mobilized from the lower uterine segment. During this surgery, differentiating the isthmocele from the abdomen can be challenging. Here we used a Foley catheter to identify the isthmocele. To do this, after mobilizing the bladder from the lower uterine segment, we inserted a Foley catheter into the uterine cavity through the cervical canal. We then filled the balloon of the catheter at the lower uterine segment under laparoscopic view, which allowed clear identification of the isthmocele pouch. The uterine defect was then incised. The isthmocele cavity was accessed, the margins of the pouch were debrided, and the edges were surgically reapproximated with continuous nonlocking single layer 2-0 polydioxanone sutures. We believed that single-layer suturing could provide for proper healing without necrosis due to suturation. During the procedure, the vesicouterine space was dissected without difficulty. A urine bag was collected with clear urine, and there was no gas leakage; thus, we considered a safety test for the bladder superfluous. Based on concerns about the possible increased risk of adhesions, we did not cover peritoneum over the suture. The patients experienced no associated complications, and she reported complete resolution of prolonged postmenstrual bleeding at a 3-month follow-up. Even though the literature is cloudy in this area, a laparoscopic approach to repairing an isthmocele is a safe and minimally invasive procedure. Our approach described here involves inserting a Foley catheter in the uterine cavity through the cervical canal, then filling the balloon in the lower uterine segment under laparoscopic view to identify the isthmocele. Copyright © 2017 AAGL. Published by Elsevier Inc. All rights reserved.
Paul, Kallyanashis; Padalhin, Andrew R.; Linh, Nguyen Thuy Ba; Kim, Boram; Sarkar, Swapan Kumar; Lee, Byong Taek
2016-01-01
A bipotential polyelectrolyte complex with biphasic calcium phosphate (BCP) powder dispersion provides an excellent option for protein adsorption and cell attachment and can facilitate enhanced bone regeneration. Application of the bipotential polyelectrolyte complex embedded in a spongy scaffold for faster healing of large segmental bone defects (LSBD) can be a promising endeavor in tissue engineering application. In the present study, a hollow scaffold suitable for segmental long bone replacement was fabricated by the sponge replica method applying the microwave sintering process. The fabricated scaffold was coated with calcium alginate at the shell surface, and genipin-crosslinked chitosan with biphasic calcium phosphate (BCP) dispersion was loaded at the central hollow core. The chitosan core was subsequently loaded with BMP-2. The electrolytic complex was characterized using SEM, porosity measurement, FTIR spectroscopy and BMP-2 release for 30 days. In vitro studies such as MTT, live/dead, cell proliferation and cell differentiation were performed. The scaffold was implanted into a 12 mm critical size defect of a rabbit radius. The efficacy of this complex is evaluated through an in vivo study, one and two month post implantation. BV/TV ratio for BMP-2 loaded sample was (42±1.76) higher compared with hollow BCP scaffold (32±0.225). PMID:27711142
Manavalan, Mary Ann; Gaziova, Ivana; Bhat, Krishna Moorthi
2013-01-01
Guiding axon growth cones towards their targets is a fundamental process that occurs in a developing nervous system. Several major signaling systems are involved in axon-guidance, and disruption of these systems causes axon-guidance defects. However, the specific role of the environment in which axons navigate in regulating axon-guidance has not been examined in detail. In Drosophila, the ventral nerve cord is divided into segments, and half-segments and the precursor neuroblasts are formed in rows and columns in individual half-segments. The row-wise expression of segment-polarity genes within the neuroectoderm provides the initial row-wise identity to neuroblasts. Here, we show that in embryos mutant for the gene midline, which encodes a T-box DNA binding protein, row-2 neuroblasts and their neuroectoderm adopt a row-5 identity. This reiteration of row-5 ultimately creates a non-permissive zone or a barrier, which prevents the extension of interneuronal longitudinal tracts along their normal anterior-posterior path. While we do not know the nature of the barrier, the axon tracts either stall when they reach this region or project across the midline or towards the periphery along this zone. Previously, we had shown that midline ensures ancestry-dependent fate specification in a neuronal lineage. These results provide the molecular basis for the axon guidance defects in midline mutants and the significance of proper specification of the environment to axon-guidance. These results also reveal the importance of segmental polarity in guiding axons from one segment to the next, and a link between establishment of broad segmental identity and axon guidance. PMID:24385932
Stefancic, Martin; Vidmar, Gaj; Blagus, Rok
2016-10-01
The probability and degree of muscle recovery after lesions of long peripheral nerves have not been assessed quantitatively. Twelve adults with closed injuries of the fibular division of the sciatic nerve with complete denervation of associated muscles were followed-up for 2-10 years. The onset of reinnervation was detected electromyographically. Calf circumference and maximum voluntary isometric contraction (MVIC) of foot dorsiflexion were measured on both sides during 2-4 visits. Reinnervation occurred in 11 patients after an average of 13 months. MVIC on the affected side was 2%-27% of that on the unaffected side (average 11%) and remained stable for the following 2-3 years. Correlations and mixed-model regressions confirmed that the degree of recovery was negatively associated with duration of denervation. Reinnervation occurs in about 90% of patients within about 1 year. About 10% of baseline dorsiflexion strength is permanently recovered, which is functionally relevant. Muscle Nerve, 2016 Muscle Nerve 54: -, 2016 Muscle Nerve 54: 702-708, 2016. © 2016 Wiley Periodicals, Inc.
Hara, Hitomi; Kawamoto, Teruya; Onishi, Yasuo; Fujioka, Hiroyuki; Nishida, Kotaro; Kuroda, Ryosuke; Kurosaka, Masahiro; Akisue, Toshihiro
2016-01-01
We report the case of a 32-year-old Japanese female with a giant cell tumor of bone involving multiple midfoot bones. Giant cell tumors of bone account for approximately 5% of all primary bone tumors and most often arise at the ends of long bones. The small bones, such as those of the hands and feet, are rare sites for giant cell tumors. Giant cell tumors of the small bones tend to exhibit more aggressive clinical behavior than those of the long bones. The present patient underwent en bloc tumor excision involving multiple tarsals and metatarsals. We reconstructed the longitudinal arch of the foot with a free vascularized fibular graft. At the 2-year follow-up visit, bony union had been achieved, with no tumor recurrence. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Rapsyn congenital myasthenic syndrome worsened by fluoxetine.
Visser, Amy C; Laughlin, Ruple S; Litchy, William J; Benarroch, Eduardo E; Milone, Margherita
2017-01-01
Fluoxetine is a selective serotonin reuptake inhibitor and long-lived open channel blocker of the acetylcholine receptor, often used in the treatment of slow-channel congenital myasthenic syndromes (CMS). We report a 42-year-old woman who had a history of episodic limb weakness that worsened after initiation of fluoxetine for treatment of depression. Genetic testing for CMS revealed a homozygous pathogenic mutation in the rapsyn (RAPSN) gene (p.Asn88Lys). Electrodiagnostic testing was performed before and 1 month after discontinuation of fluoxetine. The 2 Hz repetitive nerve stimulation of the fibular and spinal accessory nerves showed a baseline decrement of 36% and 14%, respectively. One month after discontinuing fluoxetine, the spinal accessory nerve decrement was no longer present, and the decrement in the fibular nerve was improved at 17%. This case demonstrates worsening of both clinical and electrophysiologic findings in a patient with CMS secondary to a RAPSN mutation treated with fluoxetine. Muscle Nerve 55: 131-135, 2017. © 2016 Wiley Periodicals, Inc.
Skelly, Jordan D; Lange, Jeffrey; Filion, Tera M; Li, Xinning; Ayers, David C; Song, Jie
2014-12-01
Bone grafts simultaneously delivering therapeutic proteins and antibiotics may be valuable in orthopaedic trauma care. Previously, we developed a poly(2-hydroxyethyl methacrylate)-nanocrystalline hydroxyapatite (pHEMA-nHA) synthetic bone graft that, when preabsorbed with 400-ng rhBMP-2/7, facilitated the functional repair of critical-size rat femoral defects. Recently, we showed that pHEMA-nHA effectively retains/releases vancomycin and rhBMP-2 in vitro. The success of such a strategy requires that the incorporation of vancomycin does not compromise the structural integrity of the graft nor its ability to promote bone healing. (1) To evaluate the ability of pHEMA-nHA-vancomycin composites in combination with 3-µg rhBMP-2 to repair 5 mm rat femoral segmental defects, and (2) To determine if the encapsulated vancomycin impairs the graft/rhBMP-2-assisted bone repair. pHEMA-nHA-vancomycin, pHEMA-nHA, or collagen sponge control with/without 3-µg rhBMP-2 were press-fit in 5 mm femoral defects in SASCO-SD male rats (289-300 g). Histology, microcomputed tomography, and torsion testing were performed on 8- and 12-week explants to evaluate the extent and quality of repair. The effect of vancomycin on the temporal absorption of endogenous BMP-2 and stromal cell-derived factor-1 was evaluated by immunohistochemistry. These factors are important for bone healing initiation and stem cell recruitment, respectively. Partial bridging of the defect with bony callus by 12 weeks was observed with pHEMA-nHA-vancomycin without rhBMP-2 while full bridging with substantially mineralized callus and partial restoration of torsional strength was achieved with 3-µg rhBMP-2. The presence of vancomycin changed the absorption patterns of endogenous proteins on the grafts, but did not appear to substantially compromise graft healing. The composite pHEMA-nHA-vancomycin preabsorbed with 3-µg rhBMP-2 promoted repair of 5 mm rat femoral segmental defects. With the sample sizes applied, vancomycin encapsulation did not appear to have a negative effect on bone healing. pHEMA-nHA-vancomycin preabsorbed with rhBMP-2 may be useful in the repair of critical-size long bone defects prone to infections.
Hamblet, Natasha S; Lijam, Nardos; Ruiz-Lozano, Pilar; Wang, Jianbo; Yang, Yasheng; Luo, Zhenge; Mei, Lin; Chien, Kenneth R; Sussman, Daniel J; Wynshaw-Boris, Anthony
2002-12-01
The murine dishevelled 2 (Dvl2) gene is an ortholog of the Drosophila segment polarity gene Dishevelled, a member of the highly conserved Wingless/Wnt developmental pathway. Dvl2-deficient mice were produced to determine the role of Dvl2 in mammalian development. Mice containing null mutations in Dvl2 present with 50% lethality in both inbred 129S6 and in a hybrid 129S6-NIH Black Swiss background because of severe cardiovascular outflow tract defects, including double outlet right ventricle, transposition of the great arteries and persistent truncus arteriosis. The majority of the surviving Dvl2(-/-) mice were female, suggesting that penetrance was influenced by sex. Expression of Pitx2 and plexin A2 was attenuated in Dvl2 null mutants, suggesting a defect in cardiac neural crest development during outflow tract formation. In addition, approximately 90% of Dvl2(-/-) mice have vertebral and rib malformations that affect the proximal as well as the distal parts of the ribs. These skeletal abnormalities were more pronounced in mice deficient for both Dvl1 and Dvl2. Somite differentiation markers used to analyze Dvl2(-/-) and Dvl1(-/-);Dvl2(-/-) mutant embryos revealed mildly aberrant expression of Uncx4.1, delta 1 and myogenin, suggesting defects in somite segmentation. Finally, 2-3% of Dvl2(-/-) embryos displayed thoracic spina bifida, while virtually all Dvl1/2 double mutant embryos displayed craniorachishisis, a completely open neural tube from the midbrain to the tail. Thus, Dvl2 is essential for normal cardiac morphogenesis, somite segmentation and neural tube closure, and there is functional redundancy between Dvl1 and Dvl2 in some phenotypes.
Zhao, Yi-Nan; Fan, Jun-Jun; Li, Zhi-Quan; Liu, Yan-Wu; Wu, Yao-Ping; Liu, Jian
2017-02-01
Calcium phosphate cement (CPC) porous scaffold is widely used as a suitable bone substitute to repair bone defect, but the optimal pore size is unclear yet. The current study aimed to evaluate the effect of different pore sizes on the processing of bone formation in repairing segmental bone defect of rabbits using CPC porous scaffolds. Three kinds of CPC porous scaffolds with 5 mm diameters and 12 mm length were prepared with the same porosity but different pore sizes (Group A: 200-300 µm, Group B: 300-450 µm, Group C: 450-600 µm, respectively). Twelve millimeter segmental bone defects were created in the middle of the radius bone and filled with different kinds of CPC cylindrical scaffolds. After 4, 12, and 24 weeks, alkaline phosphatase (ALP), histological assessment, and mechanical properties evaluation were performed in all three groups. After 4 weeks, ALP activity increased in all groups but was highest in Group A with smallest pore size. The new bone formation within the scaffolds was not obvious in all groups. After 12 weeks, the new bone formation within the scaffolds was obvious in each group and highest in Group A. At 24 weeks, no significant difference in new bone formation was observed among different groups. Besides the osteoconductive effect, Group A with smallest pore size also had the best mechanical properties in vivo at 12 weeks. We demonstrate that pore size has a significant effect on the osteoconductivity and mechanical properties of calcium phosphate cement porous scaffold in vivo. Small pore size favors the bone formation in the early stage and may be more suitable for repairing segmental bone defect in vivo. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Hautamäki, Mikko P; Aho, Allan J; Alander, Pasi; Rekola, Jami; Gunn, Jarmo; Strandberg, Niko; Vallittu, Pekka K
2008-08-01
Polymer technology has provided solutions for filling of bone defects in situations where there may be technical or biological complications with autografts, allografts, and metal prostheses. We present an experimental study on segmental bone defect reconstruction using a polymethylmethacrylate-(PMMA-) based bulk polymer implant prosthesis. We concentrated on osteoconductivity and surface characteristics. A critical size segment defect of the rabbit tibia in 19 animals aged 18-24 weeks was reconstructed with a surface porous glass fiber-reinforced (SPF) prosthesis made of polymethylmethacrylate (PMMA). The biomechanical properties of SPF implant material were previously adjusted technically to mimic the properties of normal cortical bone. A plain PMMA implant with no porosity or fiber reinforcement was used as a control. Radiology, histomorphometry, and scanning electron microscopy (SEM) were used for analysis of bone growth into the prosthesis during incorporation. The radiographic and histological incorporation model showed good host bone contact, and strong formation of new bone as double cortex. Histomorphometric evaluation showed that the bone contact index (BCI) at the posterior surface interface was higher with the SPF implant than for the control. The total appositional bone growth over the posterior surface (area %) was also stronger for the SPF implant than for controls. Both bone growth into the porous surface and the BCI results were related to the quality, coverage, and regularity of the microstructure of the porous surface. Porous surface structure enhanced appositional bone growth onto the SPF implant. Under load-bearing conditions the implant appears to function like an osteoconductive prosthesis, which enables direct mobilization and rapid return to full weight bearing.
Wieding, Jan; Lindner, Tobias; Bergschmidt, Philipp; Bader, Rainer
2015-04-01
Open-porous titanium scaffolds for large segmental bone defects offer advantages like early weight-bearing and limited risk of implant failure. The objective of this experimental study was to determine the biomechanical behavior of novel open-porous titanium scaffolds with mechanical-adapted properties in vivo. Two types of the custom-made, open-porous scaffolds made of Ti6Al4V (Young's modulus: 6-8 GPa and different pore sizes) were implanted into a 20 mm segmental defect in the mid-diaphysis of the metatarsus of sheep, and were stabilized with an osteosynthesis plate. After 12 and 24 weeks postoperatively, torsional testing was performed on the implanted bone and compared to the contralateral non-treated side. Maximum torque, maximum angle, torsional stiffness, fracture energy, shear modulus and shear stress were investigated. Furthermore, bone mineral density (BMD) of the newly formed bone was determined. Mechanical loading capabilities for both scaffolds were similar and about 50% after 12 weeks (e.g., max. torque of approximately 20 Nm). A further increase after 24 weeks was found for most of the investigated parameters. Results for torsional stiffness and shear modulus as well as bone formation depended on the type of scaffold. Increased BMD after 24 weeks was found for one scaffold type but remained constant for the other one. The present data showed the capability of mechanically adapted open-porous titanium scaffolds to function as bone scaffolds for large segmental defects and the influence of the scaffold's stiffness. A further increase in the biomechanical stability can be assumed for longer observation periods of greater than six months. Copyright © 2014 Elsevier Ltd. All rights reserved.
Giordano, Jessica; Khung, Suonita; Duhamel, Alain; Hossein-Foucher, Claude; Bellèvre, Dimitri; Lamblin, Nicolas; Remy, Jacques; Remy-Jardin, Martine
2017-04-01
To compare lung perfusion in PAH and pCTEPH on dual-energy CT (DECT) examinations. Thirty-one patients with PAH (group 1; n = 19) and pCTEPH (group 2; n = 12) underwent a dual-energy chest CTA with reconstruction of diagnostic and perfusion images. Perfusion alterations were analysed at a segmental level. V/Q scintigraphy was available in 22 patients (group 1: 13/19; group 2: 9/12). CT perfusion was abnormal in 52.6 % of group 1 patients and in 100 % of group 2 patients (p = 0.0051). The patterns of perfusion alteration significantly differed between the two groups (p < 0.0001): (1) in group 1, 96.6 % of segments with abnormal perfusion showed patchy defects; (2) in group 2, the most frequent abnormalities consisted of patchy (58.5 %) and PE-type (37.5 %) defects. Paired comparison of CT perfusion and scintigraphy showed concordant findings in 76.9 % of group 1 (10/13) and 100 % of group 2 (9/9) patients, with a predominant or an exclusive patchy pattern in group 1 and a mixed pattern of abnormalities in group 2. Lung perfusion alterations at DECT are less frequent and more homogeneous in PAH than in pCTEPH, with a high level of concordant findings with V/Q scintigraphy. • Depiction of chronic pulmonary embolism exclusively located on peripheral arteries is difficult. • The main differential diagnosis of pCTEPH is PAH. • The pattern of DECT perfusion changes can help differentiate PAH and pCETPH. • In PAH, almost all segments with abnormal perfusion showed patchy defects. • In pCTEPH, patchy and PE-type defects were the most frequent abnormalities.
Sugihara, Fumie; Murata, Satoru; Ueda, Tatsuo; Yasui, Daisuke; Yamaguchi, Hidenori; Miki, Izumi; Kawamoto, Chiaki; Uchida, Eiji; Kumita, Shin-Ichiro
2017-06-01
To investigate haemodynamic changes in hepatocellular carcinoma (HCC) and liver under hepatic artery occlusion. Thirty-eight HCC nodules in 25 patients were included. Computed tomography (CT) during hepatic arteriography (CTHA) with and without balloon occlusion of the hepatic artery was performed. CT attenuation and enhancement volume of HCC and liver with and without balloon occlusion were measured on CTHA. Influence of balloon position (segmental or subsegmental branch) was evaluated based on differences in HCC-to-liver attenuation ratio (H/L ratio) and enhancement volume of HCC and liver. In the segmental group (n = 20), H/L ratio and enhancement volume of HCC and liver were significantly lower with balloon occlusion than without balloon occlusion. However, in the subsegmental group (n = 18), H/L ratio was significantly higher and liver enhancement volume was significantly lower with balloon occlusion; HCC enhancement volume was similar with and without balloon occlusion. Rate of change in H/L ratio and enhancement volume of HCC and liver were lower in the segmental group than in the subsegmental group. There were significantly more perfusion defects in HCC in the segmental group. Hepatic artery occlusion causes haemodynamic changes in HCC and liver, especially with segmental occlusion. • Hepatic artery occlusion causes haemodynamic changes in hepatocellular carcinoma and liver. • Segmental occlusion decreased rate of change in hepatocellular carcinoma-to-liver attenuation ratio. • Subsegmental occlusion increased rate of change in hepatocellular carcinoma-to-liver attenuation ratio. • Hepatic artery occlusion decreased enhancement volume of hepatocellular carcinoma and liver. • Hepatic artery occlusion causes perfusion defects in hepatocellular carcinoma.
Takase, Bonpei; Masaki, Nobuyuki; Hattori, Hidemi; Ishihara, Masayuki; Kurita, Akira
2009-06-01
The electrocardiographic index of QT dispersion (QTd) is related to the occurrence of arrhythmia. In patients with suspected or known coronary artery disease, QTd may be affected by exercise. We investigated whether QTd that is automatically calculated by a newly developed computer system could be used as a marker of exercise-induced myocardial ischemia. The design of this study was prospective and observational. Eighty-three consecutive patients were enrolled in this study. Their QTd was measured at rest and after 3 min of exercise during exercise-stress Thallium-201 scintigraphy and compared with conventional ST-segment changes. The patients were classified into 4 groups (normal group, redistribution group, fixed defect group, redistribution with fixed defect group) based on the result of single photon emission computed tomography. As statistical analysis, one-way ANOVA with post-hoc Scheffe's method, receiver-operating characteristics (ROC) and multiple logistic regression analysis were performed. At rest, QTd was significantly greater (p<0.05) in the fixed defect group (52+/-21 ms) and the redistribution with fixed defect group (53+/-20 ms) than in the normal group (32+/-14 ms) and the redistribution group (31+/-16 ms). However, QTd tended to increase after exercise in the redistribution group, while QTd tended to decrease in the normal group, the fixed defect group, and the redistribution with fixed defect group (QTd after exercise, normal group, 28+/-17 ms, redistribution group, 35+/-19 ms, fixed defect group, 43+/-25 ms, redistribution with fixed defect group, 49+/-27 ms). Exercise significantly increased QTcd (RR interval-corrected QT dispersion) in the redistribution group. The best cut-off values of QTd and QTcd obtained from ROC curves for exercise-induced myocardial ischemia were 41.6 ms and 40.4 ms, respectively (Qtd--AUC 0.68, 95%CI 0.53- 0.83 and QTcd--AUC 0.67, 95%CI 0.55-0.80). Using these values as cut-off ones, QTd, QTcd, and conventional ST-segment change had comparable sensitivities and specificities for detecting exercise-induced myocardial ischemia (sensitivity - 60%, 58% and 49%, respectively;specificity - 78%, 80% and 83%, respectively). In addition, multiple logistic regression analysis showed that QTd (OR=2.01, 95%CI 1.15-4.10, p<0.05), QTcd (OR=2.12, 95% CI 1.02-4.30, p<0.05) and ST-segment change (OR=1.89, 95%CI 1.03-3.40, p<0.05), were the significantly associated with exercise-induced myocardial ischemia. QT dispersion and/or QTcd after exercise could be a useful marker for exercise-induced myocardial ischemia in routine clinical practice.
Outcome of Distal Both Bone Leg Fractures Fixed by Intramedulary Nail for Fibula & MIPPO in Tibia.
Gupta, Anil; Anjum, Rashid; Singh, Navdeep; Hackla, Shafiq
2015-04-01
Fractures of the distal third of the tibia are mostly associated with a fibular fracture that often requires fixation. The preferred treatment of distal tibial fracture is the minimally invasive percutaneous plate osteosynthesis (MIPPO) procedure. However, there are no clear cut guidelines on fixation of the fibular fracture and currently most orthopedic surgeons use a plate osteosynthesis for the fibula as well. A common complication associated with dual plating is an increased chance of soft tissue necrosis, infection, and in some cases resulting in an exposed implant. We conducted a prospective study to analyze the results of fractures of the distal in both leg bones managed by the MIPPO procedure for tibial fractures and a rush nail for fibular fractures. The study was conducted in a tertiary care hospital from November 2012 to May 2014, a total of 30 fractures in 30 patients (18 males, 12 females) with a mean age of 42.4 years (26-60 years) were treated in our institution in the aforesaid time period with MIPPO for tibia and rush nail for fibular fractures. All the cases were operated on by a single surgeon in emergency within 24 hours. The patients with skin blistering and compound fractures were excluded from this study. Rehabilitative measures were proceeded as per patient's pain profile, isometric and isotonic exercises were started on the first post-operative day, with full weight bearing at 10-12 weeks after assessing clinical and radiological union. Regular follow up of patients was done, radiographs were taken at the immediate post-operative period and at 3, 6, 12 and 24 weeks. All the patients were available for regular follow up. Radiological and clinical union proceeded normally in all the patients, no patients had signs of any deep infection, delayed union or nonunion, three patients had a superficial infection of the tibial incision that healed with a change in antibiotic. The use of dual plating for fixation of the lower tibia and fibula fractures is often associated with soft tissue complications, exposed implant, and increased risk of infection. We conclude that in fractures of the distal tibia and fibula it is better to use a rush nail for the fibula with a concurrent MIPPO for the tibia for the reasons cited above. Moreover, with the use of rush nail the cost of implant is also reduced, which is a very important factor in developing countries.
2016-10-01
characterization of a novel external fixator for dynamizing ovine osseous defects. Poster No. 2185. Orthopedic Research Society Annual Meeting, Orlando...REPORT: Annual PREPARED FOR: U.S. Army Medical Research and Materiel Command Fort Detrick, Maryland 21702-5012 DISTRIBUTION STATEMENT...SPONSOR/MONITOR’S ACRONYM(S) U.S. Army Medical Research and Materiel Command Fort Detrick, Maryland 21702-5012 11. SPONSOR/MONITOR’S REPORT NUMBER(S
DeFazio, Michael Vincent; Han, Kevin Dong
2014-01-01
The composite anterolateral thigh flap with vascularized fascia lata has emerged as a workhorse at our institution for complex Achilles defects requiring both tendon and soft tissue reconstruction. Safe elevation of this flap, however, is occasionally challenged by absent or inadequate perforators supplying the anterolateral thigh. When discovered intraoperatively, alternative options derived from the same vascular network can be pursued. We present the case of a 74-year-old male who underwent composite Achilles defect reconstruction using a segmental rectus femoris myofascial free flap. Following graduated rehabilitation, postoperatively, the patient resumed full activity and was able to ambulate on his tip-toes. At 1-year follow-up, active total range of motion of the reconstructed ankle exceeded 85% of the unaffected side, and donor site morbidity was negligible. American Orthopaedic Foot and Ankle Society and Short Form-36 scores improved by 78.8% and 28.8%, respectively, compared to preoperative baseline assessments. Based on our findings, we advocate for use of the combined rectus femoris myofascial free flap as a rescue option for reconstructing composite Achilles tendon/posterior leg defects in the setting of inadequate anterolateral thigh perforators. To our knowledge, this is the first report to describe use of this flap for such an indication. PMID:24883281
Spine Patterning Is Guided by Segmentation of the Notochord Sheath.
Wopat, Susan; Bagwell, Jennifer; Sumigray, Kaelyn D; Dickson, Amy L; Huitema, Leonie F A; Poss, Kenneth D; Schulte-Merker, Stefan; Bagnat, Michel
2018-02-20
The spine is a segmented axial structure made of alternating vertebral bodies (centra) and intervertebral discs (IVDs) assembled around the notochord. Here, we show that, prior to centra formation, the outer epithelial cell layer of the zebrafish notochord, the sheath, segments into alternating domains corresponding to the prospective centra and IVD areas. This process occurs sequentially in an anteroposterior direction via the activation of Notch signaling in alternating segments of the sheath, which transition from cartilaginous to mineralizing domains. Subsequently, osteoblasts are recruited to the mineralized domains of the notochord sheath to form mature centra. Tissue-specific manipulation of Notch signaling in sheath cells produces notochord segmentation defects that are mirrored in the spine. Together, our findings demonstrate that notochord sheath segmentation provides a template for vertebral patterning in the zebrafish spine. Copyright © 2018 The Author(s). Published by Elsevier Inc. All rights reserved.
The Palatal Approach to Distraction Osteogenesis of the Anterior Maxillary Alveolus.
Bell, Robert E
2015-07-01
This report describes the palatal approach to gain access for osteodistraction of the anterior maxilla to improve the vector of force during distraction. This case report illustrates a novel approach to anterior maxillary osteodistraction. The palatal approach allows the maxillary segment to be moved anteriorly and inferiorly. This is in contrast to the buccal approach, in which the palatal tissue creates a vector of force toward the palate. The vascular pedicle for the transport segment is the labial mucosa and musculature. In the present case, the alveolar segment was advanced 3.6 mm anteriorly and 12.2 mm inferiorly as measured by pre- and postoperative computed tomograms. This patient with a large vertical alveolar defect and high smile line had successful restoration with dental implants. The result has been stable for 14 months. In this case, the palatal approach to the anterior maxillary osteotomy was shown to be an effective method of reconstructing a large vertical anterior defect. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
History, heresy and radiology in scientific discovery.
McCredie, J
2009-10-01
Nowadays, most drugs reach the market after research has established their pharmacology, safety and efficacy. That was not always the case 50 years ago. Thalidomide was used before its target cell or mode of action were known. Commencing with the thalidomide catastrophe--an epidemic of gross birth defects (1958-1962)--thalidomide's origins are revisited to show how this drug came to be made and sold in the 1950s. Thalidomide intersected with Australian radiology in the 1970s. The site and mode of action of the drug was deduced from X-rays of thalidomide-induced bone defects, which have classical radiological signs of sensory neuropathic osteoarthropathy. The longitudinal reduction deformities follow the distribution of segmental sensory innervation of the limb skeleton, indicating neural crest as the target organ. Injury to one level of neural crest halts normal neurotrophism and deletes the dependent segment--a previously unrecognised embryonic mechanism that explains most non-genetic birth defects. The final common pathway is neural crest injury and failure of normal neurotrophism to result in longitudinal reduction deformities, for example, phocomelia.
Lee, Ji Eun; Ahn, Ki Su; Park, Keun Heung; Pak, Kang Yeun; Kim, Hak Jin; Byon, Ik Soo; Park, Sung Who
2017-05-30
The discrepancy in the choroidal circulation between anatomy and function has remained unsolved for several decades. Postmortem cast studies revealed extensive anastomotic channels, but angiographic studies indicated end-arterial circulation. We carried out experimental fat embolism in cats and electric circuit simulation. Perfusion defects were observed in two categories. In the scatter perfusion defects suggesting an embolism at the terminal arterioles, fluorescein dye filled the non-perfused lobule slowly from the adjacent perfused lobule. In the segmental perfusion defects suggesting occlusion of the posterior ciliary arteries, the hypofluorescent segment became perfused by spontaneous resolution of the embolism without subsequent smaller infarction. The angiographic findings could be simulated with an electric circuit. Although electric currents flowed to the disconnected lobule, the level was very low compared with that of the connected ones. The choroid appeared to be composed of multiple sectors with no anastomosis to other sectors, but to have its own anastomotic arterioles in each sector. Blood flows through the continuous choriocapillaris bed in an end-arterial nature functionally to follow a pressure gradient due to the drainage through the collector venule.
The retinal phenotype of Usher syndrome: pathophysiological insights from animal models.
El-Amraoui, Aziz; Petit, Christine
2014-03-01
The Usher syndrome (USH) is the most prevalent cause of inherited deaf-blindness. Three clinical subtypes, USH1-3, have been defined, and ten USH genes identified. The hearing impairment due to USH gene defects has been shown to result from improper organisation of the hair bundle, the sound receptive structure of sensory hair cells. In contrast, the cellular basis of the visual defect is less well understood as this phenotype is absent in almost all the USH mouse models that faithfully mimic the human hearing impairment. Structural and molecular interspecies discrepancies regarding photoreceptor calyceal processes and the association with the distribution of USH1 proteins have recently been unravelled, and have led to the conclusion that a defect in the USH1 protein complex-mediated connection between the photoreceptor outer segment and the surrounding calyceal processes (in both rods and cones), and the inner segment (in rods only), probably causes the USH1 retinal dystrophy in humans. Copyright © 2013 Académie des sciences. Published by Elsevier SAS. All rights reserved.
Chevron Defect at the Intersection of Grain Boundaries with Free Surfaces in Au
NASA Astrophysics Data System (ADS)
Radetic, T.; Lançon, F.; Dahmen, U.
2002-08-01
We have identified a new defect at the intersection between grain boundaries and surfaces in Au using atomic resolution transmission electron microscopy. At the junction line of 90° <110> tilt grain boundaries of (110)-(001) orientation with the free surface, a small segment of the grain boundary, about 1nm in length, dissociates into a triangular region with a chevronlike stacking disorder and a distorted hcp structure. The structure and stability of these defects are confirmed by atomistic simulations, and we point out the relationship with the one-dimensional incommensurate structure of the grain boundary.
Kumar, Avs Anil; Kumar, P G; Swami, Ajay; Dinker, Yateendra
2018-01-01
After a primary transluminal coronary angioplasty (PTCA) following AMI (acute myocardial infarction), the perfusion defect and LV (left ventricular) function recover/change over a period of time. The analysis immediately after the procedure may not be true depiction of the exact success of the procedure. There is varying and scanty information available on the natural course of changes in these parameters after a successful PTCA. We hypothesized that majority of change occurs at 3-4 month period. Hence, we undertook this study on the natural course of recovery/changes occurring in perfusion defect size and LV function in first 3 months after primary angioplasty MATERIAL AND METHODS: 30 consecutive cases of first AMI who were taken up for Primary angioplasty were enrolled into the study. Resting MPI(Myocardial perfusion imaging) was done within 24-72 hrs of admission using Tc-99m-Tetrofosmin and after 10-14 weeks. Analysis of LVEF (left ventricular ejection fraction), summed segmental score and extent of perfusion defect was done. Images were processed using autocardiac software of emory tool box and quantification was done using QPS (quantitative perfusion SPECT) and QGS (qualitative perfusion SPECT) softwares. 20 segment scoring method was used for quantification on bull's eye images. Student t test (two tailed, dependent) was used to find the significance of study parameters on continuous scale within each group. Effect size was computed to find the effect. Pearson correlation between perfusion defect and LVEF was performed at acute stage and after 10-14 weeks. The average acute perfusion defect extent was 19.76 ± 12.89% which after 3months became 16.79 ± 12.61%. The summed segmental score changed from 14.31 ± 10.58 to 11.38 ± 10.03 and LVEF improved from 48.40 ± 13.15% to 53.37 ± 12.8%. There was significant improvement in LVEF from acute setting to 10-14 weeks (p = 0.001). There was significant lowering of summed score (p = 0.007). Perfusion defect size showed significant reduction (p = 0.030). Three patients showed deterioration in perfusion defect size and in summed score with reduction in LVEF. Four patients had no change in any of the parameters. Correlation between perfusion defect and LVEF was strong both at baseline (r = -0.705, p < 0.001) and after 10-18 weeks (r = -0.766, p < 0.001). The changes we found in 3 months are similar to earlier studies and also to studies using follow up at 6 months to 1 year. We feel that 3 months is a good enough time to accurately assess the success of primary angioplasty.
Fang, Zhong; Giambini, Hugo; Zeng, Heng; Camp, Jon J.; Dadsetan, Mahrokh; Robb, Richard A.; An, Kai-Nan; Yaszemski, Michael J.
2014-01-01
A novel biodegradable copolymer, poly(propylene fumarate-co-caprolactone) [P(PF-co-CL)], has been developed in our laboratory as an injectable scaffold for bone defect repair. In the current study, we evaluated the ability of P(PF-co-CL) to reconstitute the load-bearing capacity of vertebral bodies with lytic lesions. Forty vertebral bodies from four fresh-frozen cadaveric thoracolumbar spines were used for this study. They were randomly divided into four groups: intact vertebral body (intact control), simulated defect without treatment (negative control), defect treated with P(PF-co-CL) (copolymer group), and defect treated with poly(methyl methacrylate) (PMMA group). Simulated metastatic lytic defects were made by removing a central core of the trabecular bone in each vertebral body with an approximate volume of 25% through an access hole in the side of the vertebrae. Defects were then filled by injecting either P(PF-co-CL) or PMMA in situ crosslinkable formulations. After the spines were imaged with quantitative computerized tomography, single vertebral body segments were harvested for mechanical testing. Specimens were compressed until failure or to 25% reduction in body height and ultimate strength and elastic modulus of each specimen were then calculated from the force–displacement data. The average failure strength of the copolymer group was 1.83 times stronger than the untreated negative group and it closely matched the intact vertebral bodies (intact control). The PMMA-treated vertebrae, however, had a failure strength 1.64 times larger compared with the intact control. The elastic modulus followed the same trend. This modulus mismatch between PMMA-treated vertebrae and the host vertebrae could potentially induce a fracture cascade and degenerative changes in adjacent intervertebral discs. In contrast, P(PF-co-CL) restored the mechanical properties of the treated segments similar to the normal, intact, vertebrae. Therefore, P(PF-co-CL) may be a suitable alternative to PMMA for vertebroplasty treatment of vertebral bodies with lytic defects. PMID:24256208
Reversibility by dipyridamole of thallium-201 myocardial scan defects in patients with sarcoidosis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tellier, P.; Paycha, F.; Antony, I.
1988-08-01
In order to clarify the significance of anginal pain and myocardial thallium-201 scan defects in cardiac sarcoidosis, the pharmacologic effect of dipyridamole on myocardial perfusion was assessed by planar thallium-201 myocardial scintigraphy in patients with sarcoidosis. Thallium-201 myocardial scintigraphy was performed at rest and after 0.56 mg/kg intravenous dipyridamole during four minutes in 16 patients with sarcoidosis. The myocardial scan (45-degree and 70-degree left anterior oblique, and anterior views) was divided into 15 segments. Results were evaluated by the number of segmental defects and with a global perfusion score (from 0 to 60) by a semi-quantitative index depending on themore » size and severity of myocardial thallium-201 defects. Thirteen of the 16 patients showed partial or total reversion of their thallium-201 defects on redistribution scanning either at rest or after dipyridamole. The mean (+/- SD) number of myocardial perfusion defects that were present in all the patients decreased from 5.31 +/- 1.78 at rest to 3.25 +/- 2.52 after redistribution (p less than 0.001) and to 2.19 +/- 2.10 after dipyridamole (p less than 0.001). The mean global perfusion score increased from 53.2 +/- 3.0 at rest to 56.2 +/- 2.9 after redistribution (p less than 0.001) and to 57.2 +/- 2.7 after dipyridamole (p less than 0.001). A significant correlation (r = 0.82, p less than 0.001) was found between the increase of global perfusion score on redistribution and after dipyridamole. The reversibility of myocardial scan defects is a common finding in sarcoidosis. It makes unlikely the role of scar fibrosis or extensive confluent granulomas as a mechanism for such defects. The effect of dipyridamole suggests the presence of reversible disorders lying at the coronary microvascular level.« less
Gupta, Ankur; Khaira, Ambar; Lal, Charanjit; Mahajan, Sandeep; Tiwari, Suresh C
2009-10-01
Noonan syndrome is characterised by short stature, typical facial dysmorphology and congenital heart defects. Urogenital abnormalities are reported in 10% of the cases. We present a 14-year-old girl with characteristic features of Noonan syndrome and nephrotic-range proteinuria. She had crossed fused ectopic kidneys. Renal biopsy showed focal segmental glomerulosclerosis. Oral steroids were instituted and she responded well. The case highlights this novel renal presentation of Noonan syndrome.
Albert, S; Cristofari, J-P; Cox, A; Bensimon, J-L; Guedon, C; Barry, B
2011-12-01
The techniques of free tissue transfers are mainly used for mandibular reconstruction by specialized surgical teams. This type of reconstruction is mostly realized in matters of head and neck cancers affecting mandibular bone and requiring a wide surgical resection and interruption of the mandible. To decrease the duration of the operation, surgical procedure involves generally two teams, one devoted to cancer resection and the other one to raise the fibular flap and making the reconstruction. For a better preparation of this surgical procedure, we propose here the use of a medical imaging software enabling mandibular reconstructions in three dimensions using the CT-scan done during the initial disease-staging checkup. The software used is Osirix®, developed since 2004 by a team of radiologists from Geneva and UCLA, working on Apple® computers and downloadable free of charge in its basic version. We report here our experience of this software in 17 patients, with a preoperative modelling in three dimensions of the mandible, of the segment of mandible to be removed. It also forecasts the numbers of fragments of fibula needed and the location of osteotomies. Copyright © 2009 Elsevier Masson SAS. All rights reserved.
Ginanneschi, Federica; Filippou, Georgios; Giannini, Fabio; Carluccio, Maria A; Adinolfi, Antonella; Frediani, Bruno; Dotti, Maria T; Rossi, Alessandro
2012-12-01
In hereditary neuropathy with liability to pressure palsies (HNPP), the increase in distal motor latencies (DMLs) is often out of proportion to the slowing of conduction velocities, but the pathophysiological mechanism is still unclear. We used a combined electrophysiological and ultrasonographic (US) approach to provide insight into this issue. Twelve HNPP subjects underwent extensive electrophysiological studies and US measurements of the cross-sectional area (CSA) of several peripheral nerves. US nerve enlargement was only observed in the carpal tunnel, Guyon's canal, the elbow and the fibular head. We did not observe US abnormalities at sites where nerve entrapment is uncommon. An increase in DMLs was observed regardless of US nerve enlargement. The increased nerve CSA only in common sites of entrapment likely reflected the well-documented nerve vulnerability to mechanical stress in HNPP. No morphometric changes were seen in the distal nerve segments where compression/entrapment is unlikely, despite the fact that the DMLs were increased. These data suggest that factors other than mechanical stress are responsible for the distal slowing of action potential propagation. We speculate that a mixture of mechanical insults and an axon-initiated process in the distal nerves underlies the distal slowing and/or conduction failure in HNPP. © 2012 Peripheral Nerve Society.
Linsen, Sabine S; Oikonomou, Annina; Martini, Markus; Teschke, Marcus
2018-05-01
The purpose was to analyze mandibular kinematics and maximum voluntary bite force in patients following segmental resection of the mandible without and with reconstruction (autologous bone, alloplastic total temporomandibular joint replacement (TMJ TJR)). Subjects operated from April 2002 to August 2014 were enrolled in the study. Condylar (CRoM) and incisal (InRoM) range of motion and deflection during opening, condylar retrusion, incisal lateral excursion, mandibular rotation angle during opening, and maximum voluntary bite force were determined on the non-affected site and compared between groups. Influence of co-factors (defect size, soft tissue deficit, neck dissection, radiotherapy, occlusal contact zones (OCZ), and time) was determined. Twelve non-reconstructed and 26 reconstructed patients (13 autologous, 13 TMJ TJR) were included in the study. InRoM opening and bite force were significantly higher (P ≤ .024), and both condylar and incisal deflection during opening significantly lower (P ≤ .027) in reconstructed patients compared with non-reconstructed. Differences between the autologous and the TMJ TJR group were statistically not significant. Co-factors defect size, soft tissue deficit, and neck dissection had the greatest impact on kinematics and number of OCZs on bite force. Reconstructed patients (both autologous and TMJ TJR) have better overall function than non-reconstructed patients. Reconstruction of segmental mandibular resection has positive effects on mandibular function. TMJ TJR seems to be a suitable technique for the reconstruction of mandibular defects including the TMJ complex.
2015-10-01
Several target genes such as Oct4, Sox2, TGFB, and Col1A1 were generally up-regulated in all sections. In distal sections, VWF, PDGFB, and EGFR were...TGFB, and Col1A1 in all sections. No significant main effects were found for target gene fold-change between outer or inner membrane position or distal
Lopera, Jorge E; Katabathina, Venkata; Bosworth, Brian; Garg, Deepak; Kroma, Ghazwan; Garza-Berlanga, Andres; Suri, Rajeev; Wholey, Michael
2015-06-01
To determine the clinical significance and potential mechanisms of segmental liver ischemia and infarction following elective creation of a transjugular intrahepatic portosystemic shunt (TIPS). A retrospective review of 374 elective TIPS creations between March 2006 and September 2014 was performed, yielding 77 contrast-enhanced scans for review. Patients with imaging evidence of segmental perfusion defects were identified. Model for End-stage Liver Disease scores, liver volume, and percentage of liver ischemia/infarct were calculated. Clinical outcomes after TIPS creation were reviewed. Ten patients showed segmental liver ischemia/infarction on contrast-enhanced imaging after elective TIPS creation. Associated imaging findings included thrombosis of the posterior division (n = 7) and anterior division (n = 3) of the right portal vein (PV). The right hepatic vein was thrombosed in 5 patients, as was the middle hepatic vein in 3 and the left hepatic vein in 1. One patient had acute thrombosis of the shunt and main PV. Three patients developed acute liver failure: 2 died within 30 days and 1 required emergent liver transplantation. One patient died of acute renal failure 20 days after TIPS creation. A large infarct in a transplant recipient resulted in biloma formation. Five patients survived without additional interventions with follow-up times ranging from 3 months to 5 years. Segmental perfusion defects are not an uncommon imaging finding after elective TIPS creation. Segmental ischemia was associated with thrombosis of major branches of the PVs and often of the hepatic veins. Clinical outcomes varied significantly, from transient problems to acute liver failure with high mortality rates. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.
Lin, Dasheng; Luo, Deqing; Lian, Kejian; Zhai, Wenliang; Ding, Zhenqi
2016-01-01
This study was conducted to determine whether in situ implantation of a dropped traumatic segmental bone fragment is safe and whether the authors' method would reduce the incidence of infectious and related complications. The authors retrospectively reviewed 16 patients with open fractures, including 11 with Gustilo-Anderson type IIIA fractures and 5 with Gustilo-Anderson type IIIB fractures who had a dropped traumatic segmental bone fragment between January 2002 and January 2012. Mean patient age was 35.4 years (range, 19-47 years). There were 10 femurs and 6 tibias. Average postoperative follow-up was 26.8 months (range, 12-60 months). The dropped traumatic segmental bone fragments were cleaned with 3% hydrogen peroxide, placed in separate sterile cups, and soaked in 1% iodophor for 30 minutes. Initial treatment included surgical debridement, wound irrigation, in situ implantation of the dropped traumatic segmental bone fragment, and temporary external fixation. Approximately 4 to 8 weeks later, after successful reconstruction of the soft tissue envelope, minimally invasive plate osteosynthesis was performed. Mean duration of treatment was 8 weeks (range, 6-14 weeks). All patients had fracture union at final follow-up. Mean healing time was 21.8 weeks (range, 14-48 weeks). One patient did not achieve primary union and required bone grafting. One patient with a Gustilo-Anderson type IIIB fracture had deep infection and removal of the dropped traumatic segmental bone fragment and bone grafting. According to the Klemm and Börner classification, 11 patients had excellent results, 3 had good results, and 2 had poor results. With adequate soft tissue coverage, this method was acceptable for the management of open fractures with bone defects. Copyright 2016, SLACK Incorporated.
Detection of small surface defects using DCT based enhancement approach in machine vision systems
NASA Astrophysics Data System (ADS)
He, Fuqiang; Wang, Wen; Chen, Zichen
2005-12-01
Utilizing DCT based enhancement approach, an improved small defect detection algorithm for real-time leather surface inspection was developed. A two-stage decomposition procedure was proposed to extract an odd-odd frequency matrix after a digital image has been transformed to DCT domain. Then, the reverse cumulative sum algorithm was proposed to detect the transition points of the gentle curves plotted from the odd-odd frequency matrix. The best radius of the cutting sector was computed in terms of the transition points and the high-pass filtering operation was implemented. The filtered image was then inversed and transformed back to the spatial domain. Finally, the restored image was segmented by an entropy method and some defect features are calculated. Experimental results show the proposed small defect detection method can reach the small defect detection rate by 94%.
Reconstruction of a Post Traumatic Anterior Maxillary Defect by Transport Distraction Osteogenesis.
Rajkumar, K; Neelakandan, R S; Devadoss, Pradeep; Bandyopadhyay, T K
2017-03-01
Rehabilitation of segmental defects of maxilla presents a reconstructive challenge to obtain an ideal osseous form and height with adequate soft tissue investment. Though variety of prosthetic and surgical reconstructive options like the use of vascularized and non vascularized bone grafts are available they produce less than optimal results. Bone transport distraction is a reliable procedure in various maxillofacial bony defect reconstruction techniques. We describe herein a technique of maxillary bone transport distraction using an indigenously designed, custom made trifocal transport distractor performed in a post traumatic avulsive defect of the anterior maxilla. Transport distraction was successful for anterior maxillary alveolar bony regeneration, with excellent soft tissue cover and vestibular depth, which also helped close an oroantral/oronasal fistula.
He, Yue; Zhu, Han Guang; Zhang, Zhi Yuan; He, Jie; Sader, Robert
2009-12-01
A total maxillectomy always causes composite defects of maxilla, zygomatic bone, orbital floor or rim, and palatal and nasal mucosa lining. This leads to significant functional and cosmetic consequences after ablative surgery. The purpose of this clinical study was to preliminarily 3-dimensionally reconstruct the defect of total maxillectomy with sufficient bone support and soft tissue lining. Three-dimensional model simulation technique and free fibula osteomyocutaneous flap flow-through from radial forearm flap were used to reconstruct a total maxillectomy defect for a 21-year-old female patient. Preoperatively, the 3-dimensional (3D) simulated resin models of skeleton and fibula were used to design the osteotomies and bone segment replacement. At surgery, a 22-cm-length free fibula was divided into 4 segments to make 1 maxilla skeletal framework in the schedule of the preoperative model surgical planning with a radial forearm flap flow-through for the free fibula flap with skin paddle to repair the palatal and nasal region. Free fibula and radial forearm flap were alive, and the patient was satisfied with the results both esthetically and functionally after dental rehabilitation which was carried out 6 months after surgery. This preliminarily clinical study and case demonstrated that: the fibula osteomyocutaneous flap is an ideal donor site in 3D total maxillectomy defect reconstruction, because of its thickness, length, and bone uniformity which makes ideal support for dental rehabilitation; the flow-through forearm radial flap not only serves as the vascular bridge to midface reconstruction, but also provides sufficient soft tissue cover for the intraoral defect; and the 3D model simulation and preoperative surgical planning are effective methods to refine reconstruction surgery, shorten the surgical time, and predict the outcome after operation.
Implications of segment mismatch for influenza A virus evolution
White, Maria C.; Lowen, Anice C.
2018-01-01
Influenza A virus (IAV) is an RNA virus with a segmented genome. These viral properties allow for the rapid evolution of IAV under selective pressure, due to mutation occurring from error-prone replication and the exchange of gene segments within a co-infected cell, termed reassortment. Both mutation and reassortment give rise to genetic diversity, but constraints shape their impact on viral evolution: just as most mutations are deleterious, most reassortment events result in genetic incompatibilities. The phenomenon of segment mismatch encompasses both RNA- and protein-based incompatibilities between co-infecting viruses and results in the production of progeny viruses with fitness defects. Segment mismatch is an important determining factor of the outcomes of mixed IAV infections and has been addressed in multiple risk assessment studies undertaken to date. However, due to the complexity of genetic interactions among the eight viral gene segments, our understanding of segment mismatch and its underlying mechanisms remain incomplete. Here, we summarize current knowledge regarding segment mismatch and discuss the implications of this phenomenon for IAV reassortment and diversity. PMID:29244017
Yang, Zhen; Bogovic, John A; Carass, Aaron; Ye, Mao; Searson, Peter C; Prince, Jerry L
2013-03-13
With the rapid development of microscopy for cell imaging, there is a strong and growing demand for image analysis software to quantitatively study cell morphology. Automatic cell segmentation is an important step in image analysis. Despite substantial progress, there is still a need to improve the accuracy, efficiency, and adaptability to different cell morphologies. In this paper, we propose a fully automatic method for segmenting cells in fluorescence images of confluent cell monolayers. This method addresses several challenges through a combination of ideas. 1) It realizes a fully automatic segmentation process by first detecting the cell nuclei as initial seeds and then using a multi-object geometric deformable model (MGDM) for final segmentation. 2) To deal with different defects in the fluorescence images, the cell junctions are enhanced by applying an order-statistic filter and principal curvature based image operator. 3) The final segmentation using MGDM promotes robust and accurate segmentation results, and guarantees no overlaps and gaps between neighboring cells. The automatic segmentation results are compared with manually delineated cells, and the average Dice coefficient over all distinguishable cells is 0.88.
Davis, Philip A.
2012-01-01
Airborne digital-image data were collected for the Arizona part of the Colorado River ecosystem below Glen Canyon Dam in 2009. These four-band image data are similar in wavelength band (blue, green, red, and near infrared) and spatial resolution (20 centimeters) to image collections of the river corridor in 2002 and 2005. These periodic image collections are used by the Grand Canyon Monitoring and Research Center (GCMRC) of the U.S. Geological Survey to monitor the effects of Glen Canyon Dam operations on the downstream ecosystem. The 2009 collection used the latest model of the Leica ADS40 airborne digital sensor (the SH52), which uses a single optic for all four bands and collects and stores band radiance in 12-bits, unlike the image sensors that GCMRC used in 2002 and 2005. This study examined the performance of the SH52 sensor, on the basis of the collected image data, and determined that the SH52 sensor provided superior data relative to the previously employed sensors (that is, an early ADS40 model and Zeiss Imaging's Digital Mapping Camera) in terms of band-image registration, dynamic range, saturation, linearity to ground reflectance, and noise level. The 2009 image data were provided as orthorectified segments of each flightline to constrain the size of the image files; each river segment was covered by 5 to 6 overlapping, linear flightlines. Most flightline images for each river segment had some surface-smear defects and some river segments had cloud shadows, but these two conditions did not generally coincide in the majority of the overlapping flightlines for a particular river segment. Therefore, the final image mosaic for the 450-kilometer (km)-long river corridor required careful selection and editing of numerous flightline segments (a total of 513 segments, each 3.2 km long) to minimize surface defects and cloud shadows. The final image mosaic has a total of only 3 km of surface defects. The final image mosaic for the western end of the corridor has areas of cloud shadow because of persistent inclement weather during data collection. This report presents visual comparisons of the 2002, 2005, and 2009 digital-image mosaics for various physical, biological, and cultural resources within the Colorado River ecosystem. All of the comparisons show the superior quality of the 2009 image data. In fact, the 2009 four-band image mosaic is perhaps the best image dataset that exists for the entire Arizona part of the Colorado River.
Guo, Xiaodong; Zheng, Qixin; Kulbatski, Iris; Yuan, Quan; Yang, Shuhua; Shao, Zengwu; Wang, Hong; Xiao, Baojun; Pan, Zhengqi; Tang, Shuo
2006-09-01
Large segmental bone defect repair remains a clinical and scientific challenge with increasing interest focused on combining gene transfer with tissue engineering techniques. Basic fibroblast growth factor (bFGF) is one of the most prominent osteogenic growth factors that has the potential to accelerate bone healing by promoting the proliferation and differentiation of mesenchymal stem cells (MSCs) and the regeneration of capillary vasculature. However, the short biological half-lives of growth factors may impose severe restraints on their clinical usefulness. Gene-based delivery systems provide a better way of achieving a sustained high concentration of growth factors locally in the defect and delivering a more biologically active product than that achieved by exogenous application of recombinant proteins. The objective of this experimental study was to investigate whether the bFGF gene modified MSCs could enhance the repair of large segmental bone defects. The pcDNA3-bFGF gene transfected MSCs were seeded on biodegradable porous beta tricalcium phosphate (beta-TCP) ceramics and allografted into the 15 mm critical-sized segmental bone defects in the radius of 18 New Zealand White rabbits. The pcDNA3 vector gene transfected MSCs were taken as the control. The follow-up times were 2, 4, 6, 8, 10 and 12 weeks. Scanning electron microscopic, roentgenographic, histologic and immunohistological studies were used to assess angiogenesis and bone regeneration. In vitro, the proliferation and differentiation of bFGF gene transfected MSCs were more active than that of the control groups. In vivo, significantly more new bone formation accompanied by abundant active capillary regeneration was observed in pores of the ceramics loaded with bFGF gene transfected MSCs, compared with control groups. Transfer of gene encoding bFGF to MSCs increases their osteogenic properties by enhancing capillary regeneration, thus providing a rich blood supply for new bone formation. This new bFGF gene enhanced tissue engineering strategy could be of potential benefit to accelerate bone healing, especially in defects caused by atrophic nonunion and avascular necrosis of the femoral head.
Ferchaud, F; Rony, L; Ducellier, F; Cronier, P; Steiger, V; Hubert, L
2017-11-01
Reconstruction of large diaphyseal bone defect is complex and the complications rate is high. This study aimed to assess a simplified technique of segmental bone transport by monorail external fixator over an intramedullary nail.A prospective study included 7 patients: 2 femoral and 5 tibial defects. Mean age was 31years (range: 16-61years). Mean follow-up was 62 months (range: 46-84months). Defects were post-traumatic, with a mean length of 7.2cm (range: 4 to 9.5cm). For 3 patients, reconstruction followed primary failure. In 4 cases, a covering flap was necessary. Transport used an external fixator guided by an intramedullary nail, at a rate of 1mm per day. One pin was implanted on either side of the distraction zone. The external fixator was removed 1 month after bone contact at the docking site. Mean bone transport time was 11 weeks (range: 7-15 weeks). Mean external fixation time was 5.1months (range: 3.5 to 8months). Full weight-bearing was allowed 5.7months (range: 3.5-13months) after initiation of transport. In one patient, a pin had to be repositioned. In 3 patients, the transported segment re-ascended after external fixatorablation, requiring repeat external fixation and resumption of transport. There was just 1 case of superficial pin infection. Reconstruction quality was considered "excellent" on the Paley-Marr criteria in 6 cases. The present technique provided excellent reconstruction quality in 6 of the 7 cases. External fixation time was shorter and resumption of weight-bearing earlier than with other reconstruction techniques, notably including bone autograft, vascularized bone graft or the induced membrane technique. Nailing facilitated control of limb axis and length. The complications rate was 50%, comparable to other techniques. This study raises the question of systematic internal fixation of the docking site, to avoid any mobilization of the transported segment. The bone quality, axial control and rapidity shown by the present technique make it well-adapted to reconstruction of diaphyseal bone defect. Four-case series. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Fossil human remains from Bolomor Cave (Valencia, Spain).
Arsuaga, Juan Luis; Fernández Peris, Josep; Gracia-Téllez, Ana; Quam, Rolf; Carretero, José Miguel; Barciela González, Virginia; Blasco, Ruth; Cuartero, Felipe; Sañudo, Pablo
2012-05-01
Systematic excavations carried out since 1989 at Bolomor Cave have led to the recovery of four Pleistocene human fossil remains, consisting of a fibular fragment, two isolated teeth, and a nearly complete adult parietal bone. All of these specimens date to the late Middle and early Late Pleistocene (MIS 7-5e). The fibular fragment shows thick cortical bone, an archaic feature found in non-modern (i.e. non-Homo sapiens) members of the genus Homo. Among the dental remains, the lack of a midtrigonid crest in the M(1) represents a departure from the morphology reported for the majority of Neandertal specimens, while the large dimensions and pronounced shoveling of the marginal ridges in the C(1) are similar to other European Middle and late Pleistocene fossils. The parietal bone is very thick, with dimensions that generally fall above Neandertal fossils and resemble more closely the Middle Pleistocene Atapuerca (SH) adult specimens. Based on the presence of archaic features, all the fossils from Bolomor are attributed to the Neandertal evolutionary lineage. Copyright © 2012 Elsevier Ltd. All rights reserved.
Natural tibialization of fibula in non-union tibia: Two cases.
Prabhat, Vinay; Vargaonkar, Gauresh S; Mallojwar, Sunil R; Kumar, Ramesh
2016-01-01
Non-union of tibia is known to be a common complication after fracture both bones of leg treated conservatively. During the course of natural healing, fibula usually unites early as it had more soft tissue attachment and vascular supply. Due to early union of fibula and absence of axial force across the tibia, it undergoes non-union. Two cases, a 32-year-old male and 65-year-old female treated conservatively for fracture both bones of leg long years back, presented to us with mild calf pain on and off. On radiological examination, there was non-union of tibia along with compensatory fibular hypertrophy to the extent that fibula became main weight bearing bone. In both the cases, we observed gross fibular hypertrophy in presence of non-union of tibia. In conservatively treated cases of fracture, both bones of leg, non-union of tibia may coexist with compensatory hypertrophy of fibula to the extent that, it becomes main weight bearing bone of the leg. We are presenting here two cases of natural tibialization of fibula along with nonunion tibia. Our article supports the theory of Wolff's law.
Prefabricated fibula free flap with dental implants for mandibular reconstruction.
Pauchet, D; Pigot, J-L; Chabolle, F; Bach, C-A
2018-03-02
Free fibula transplant is routinely used for mandibular reconstruction in head and neck cancer. Dental rehabilitation, the objective of mandibular reconstruction, requires the use of dental implants as supports for fixed or removable dentures. Positioning of fibular bone grafts and implants determines implant osseointegration and the possibilities of dental rehabilitation. Prefabrication of a fibula free flap with dental implants prior to harvesting as a free flap can promote implant osseointegration. The position of the implants must then be precisely planned. Virtual surgery and computer-assisted design and prefabrication techniques are used to plan the reconstruction and then reproduce this planning by means of tailored fibula and mandible cutting guides, thereby ensuring correct positioning of fibular bone fragments and implants. The prefabricated fibula free flap technique requires two surgical procedures (prefabrication and flap transfer) and precise preoperative planning. Prefabricated fibula free flap with dental implants, by improving the quality of osseointegration of the implants before flap transfer, extends the possibilities of prosthetic rehabilitation in complex secondary mandibular reconstructions. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Ready-to-Use Tissue Construct for Military Bone and Cartilage Trauma
2012-10-01
times. We hypothesize that our Ready-to-Use constructs can successfully restore 3 cm critical size segmental defects in dog tibiae. We will examine the...defects) of the grant. The approved IACUC protocol permits 3 pilot dogs for Aim 1 and 3 pilot dogs for Aim 2. Several minor modifications to the...original IACUC protocol were required which are provided in the Appendix. All the pilot dogs were to receive scaffolds composed of 90% poly-caprolactone
Pathology of Podocytopathies Causing Nephrotic Syndrome in Children.
Ranganathan, Sarangarajan
2016-01-01
Nephrotic syndrome (NS) in children includes a diverse group of diseases that range from genetic diseases without any immunological defects to causes that are primarily due to immunological effects. Recent advances in molecular and genomic studies have resulted in a plethora of genetic defects that have been localized to the podocyte, the basic structure that is instrumental in normal filtration process. Although the disease can manifest from birth and into adulthood, the primary focus of this review would be to describe the novel genes and pathology of primary podocyte defects that cause NS in children. This review will restrict itself to the pathology of congenital NS, minimal change disease (MCD), and its variants and focal segmental glomerulosclerosis (FSGS). The two major types of congenital NS are Finnish type characterized by dilated sausage shaped tubules morphologically and diffuse mesangial sclerosis characterized by glomerulosclerosis. MCD has usually normal appearing biopsy features on light microscopy and needs electron microscopy for diagnosis, whereas FSGS in contrast has classic segmental sclerosing lesions identified in different portions of the glomeruli and tubular atrophy. This review summarizes the pathological characteristics of these conditions and also delves into the various genetic defects that have been described as the cause of these primary podocytopathies. Other secondary causes of NS in children, such as membranoproliferative and membranous glomerulonephritis, will not be covered in this review.
Seifi, M; Walter, M A
2018-06-01
Axenfeld-Rieger syndrome (ARS) is a clinically and genetically heterogeneous group of developmental disorders affecting primarily the anterior segment of the eye, often leading to secondary glaucoma. Patients with ARS may also present with systemic changes, including dental defects, mild craniofacial dysmorphism, and umbilical anomalies. ARS is inherited in an autosomal-dominant fashion; the underlying defect in 40% of patients is mutations in PITX2 or FOXC1. Here, an overview of the clinical spectrum of ARS is provided. As well, the known underlying genetic defects, clinical diagnostic possibilities, genetic counseling and treatments of ARS are discussed in detail. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Zhang, Lan; Lü, Lei; Wu, Hua-wei; Zhang, Hao; Zhang, Ji-wei
2011-12-06
To present our initial experiences with pulmonary high-definition multidetector computed tomography (HDCT) in patients with acute venous thromboembolism (AVTE) to evaluate their corresponding clinical manifestations. Since December 2009 to March 2010, 23 AVTE patients underwent HDCT at our hospital. Pulmonary embolism (PE) was diagnosed based on the 3D-reconstructed images of computed tomography pulmonary angiography (CTPA). The post processed data were collected by spectral imaging system software to detect the iodine distribution maps. Perfusion defects, calculated as the values of iodine content, were compared with those of normal lung parenchymal perfusion in the absence of PE. Among them, 14 AVTE patients were definitely diagnosed with PE. Prior to anticoagulant therapy, their values of iodine content in defective perfusion area were significantly lower than those in normal perfusion area. After a 3-month anticoagulant therapy, the values of iodine content for the defective perfusion area increased significantly (P < 0.05). There was no significant correlation between the values of iodine content for segmental/subsegmental filling defect area and clinical risk score of DVT (r = 2.68, P > 0.05). But there was a significant negative correlation between the values of iodine content for segmental/subsegmental filling defection area and clinical probability score of PE (r = 0.78, P < 0.05). HDCT is a promising modality of visualizing pulmonary microvasculature as a correlative manifestation of regional perfusion. PE results in hypoperfusion with decreased values of iodine content in affected lung parenchyma. Hemodynamic changes in affected areas correlate with the severity of clinical manifestations of PE.
Seyhan Karatepe, Arzu; Menteş, Jale; Erakgün, E Tansu; Afrashi, Filiz; Nalçacı, Serhad; Akkın, Cezmi; Ateş, Yeşim
2018-04-01
To determine the qualitative and quantitative vitreoretinal interface characteristics with spectral domain optical coherence tomography (SD-OCT) in eyes with macular hole (MH) and investigate their relation with best corrected visual acuity (BCVA) and MH duration. Sixty-one eyes of 46 consecutive patients diagnosed with idiopathic MH were included in the study. The mean age of the patients was 66.7±7.5 (51-79) years. Complete ophthalmologic examination and SD-OCT examination were performed in all eyes and MH stages were determined according to SD-OCT findings. Qualitative characteristics of the vitreoretinal interface were investigated, including vitreomacular traction, vitreopapillary traction, maculopapillary traction, vitreoschisis, intraretinal cyst, presence of epiretinal membrane, and the integrity of the photoreceptor inner segment-outer segment junction (IS/OS) and external limiting membrane (ELM). In addition, MH diameter, MH base diameter (MHBD), ELM defect diameter, IS/OS defect diameter, and MH height were quantitatively measured and the MH index was calculated. Out of 61 eyes, 9.8% were classified as stage 1a, 19.7% as stage 1b, 18% as stage 2, 23% as stage 3, and 29.5% as stage 4. Mean BCVA was 0.28±0.24 (1 mps-1.0) Snellen and MH duration was 10.08±18.6 (1-108) months. The most common interface characteristics associated with MH were determined as intraretinal cyst (91.8%), IS/OS defect (78.7%) and ELM defect (63.9%). Duration and stage of MH were inversely proportional to BCVA but directly proportional to the presence and diameter of IS/OS and ELM defects. BCVA was significantly lower in eyes with IS/OS and ELM defects (p<0.0001; p<0.0001 Mann-Whitney U test). We determined that the most important factors affecting BCVA in cases with idiopathic MH were MH stage, MH duration, MHBD, and the presence and diameter of IS/OS and ELM defects, which suggests that these parameters should be considered while making decisions about prognosis and treatment.
Anterior segment dysgenesis (Peters' anomaly) in two snow leopard (Panthera uncia) cubs.
Hamoudi, Hassan; Rudnick, Jens-Christian; Prause, Jan U; Tauscher, Kerstin; Breithaupt, Angele; Teifke, Jens P; Heegaard, Steffen
2013-07-01
Two sibling snow leopards, a male and a female, with bilateral anterior segment dysgenesis (ASD), are reported. Both snow leopards also had colobomas of both upper eyelids. All eyes exhibited a central corneal opacity associated with a defect in posterior corneal stroma, endothelium and Descemet's membrane. Iris strands were present attached to the termination of Descemet's membrane and to the periphery of the posterior corneal defect. The iris was hypoplastic, and cataract was present in all four eyes. The left eye of the female was microphthalmic, with no trabecular meshwork and with persistent remnant of the hyaloid artery. The male had hydrocephalus and thus some of the features of Peters' plus syndrome (Peters' anomaly in addition to systemic malformations). The histological findings in the eyes of these snow leopard siblings are identical with those described in humans with Peters' anomaly. © 2012 American College of Veterinary Ophthalmologists.
Fixation Release and the Bone Bandaid: A New Bone Fixation Device Paradigm
Shayesteh Moghaddam, Narges; Jahadakbar, Ahmadreza; Amerinatanzi, Amirhesam; Skoracki, Roman; Miller, Michael; Dean, David; Elahinia, Mohammad
2017-01-01
The current gold standard of care for mandibular segmental defeat reconstruction is the use of Ti-6Al-4V immobilization hardware and fibular double barrel graft. This method is often successful immediately at restoring mandible function, however the highly stiff fixation hardware causes stress shielding of the grafted bone and stress concentration in the fixation device over time which can lead to fixation device failure and revision surgery. The purpose of reconstructive surgery could be to create normal stress trajectories in the mandible following engraftment. We investigate the use of a two stage mechanism which separates the immobilization/healing and regenerative phases of mandibular segmental defect treatment. The device includes the use of a very stiff, Ti-6Al-4V, releasable mechanism which assures bone healing. Therefore it could be released once the reconstructed boney tissue and any of its ligamentous attachments have completely healed. Underneath the released Ti-6Al-4V plate would be a pre-loaded nitinol (NiTi) wire-frame apparatus that facilitates the normal stress-strain trajectory through the engrafted bone after the graft is healed in place and the Ti-6Al-4V fixation device has been released. Due to the use of NiTi wires forming a netting that connects vascularized bone and possibly bone chips, bone grafts are also more likely to be incorporate rather than to resorb. We first evaluated a healthy adult mandible during normal mastication to obtain the normal stress-strain distribution. Then, we developed the finite element (FE) model of the mandibular reconstruction (in the M1-3 region) with the proposed fixation device during the healing (locked state) and post-healing (released state) periods. To recreate normal stress trajectory in the reconstructed mandible, we applied the Response Surface Methodology (RMS) to optimize the Bone Bandaid geometry (i.e., wire diameters and location). The results demonstrate that the proposed mechanism immobilizes the grafted bone in the locked state properly since the maximum resultant gap (21.54 micron) between the graft and host mandible surfaces are in the safe region (less than 300 micron). By considering the von Mises criteria for failure, FE analysis together with experimental studies (i.e., compressive and tensile testing on the inferior and superior fixation devices, respectively) confirm that the proposed fixation devices do not fail, showing safety factor of at least 10.3. Based on the Response Surface Methodology (RSM) technique, the optimal parameter values for the wires are achieved (0.65 mm and 1 mm for the superior and inferior wires, respectively) and the required level of preload on each wire are calculated (369.8 N and 229 N for the inferior and superior wires, respectively). The FE results for stress distribution on the reconstructed mandible during the released state closely match that of a healthy mandible. PMID:28952484
Goumeidane, Aicha Baya; Nacereddine, Nafaa; Khamadja, Mohammed
2015-01-01
A perfect knowledge of a defect shape is determinant for the analysis step in automatic radiographic inspection. Image segmentation is carried out on radiographic images and extract defects indications. This paper deals with weld defect delineation in radiographic images. The proposed method is based on a new statistics-based explicit active contour. An association of local and global modeling of the image pixels intensities is used to push the model to the desired boundaries. Furthermore, other strategies are proposed to accelerate its evolution and make the convergence speed depending only on the defect size as selecting a band around the active contour curve. The experimental results are very promising, since experiments on synthetic and radiographic images show the ability of the proposed model to extract a piece-wise homogenous object from very inhomogeneous background, even in a bad quality image.
Qu, Jinfeng; Velaga, Swetha Bindu; Hariri, Amir H; Nittala, Muneeswar Gupta; Sadda, Srinivas
2017-08-22
The junctional zone at the border of areas of geographic atrophy (GA) in eyes with nonneovascular age-related macular degeneration is an important target region for future therapeutic strategies. The goal of this study was to perform a detailed classification and quantitative characterization of the junctional zone using spectral domain optical coherence tomography. Spectral domain optical coherence tomography volume cube scans (Spectralis OCT, 1024 × 37, Automatic Real Time > 9) were obtained from 15 eyes of 11 patients with GA because of nonneovascular age-related macular degeneration. Volume optical coherence tomography data were imported into previously described validated grading software (3D-OCTOR), and manual segmentation of the retinal pigment epithelium (RPE) and photoreceptor layers was performed on all B-scans (total of 555). Retinal pigment epithelium and photoreceptor defect maps were produced for each case. The borders of the photoreceptor defect area and RPE defect area were delineated individually on separate annotation layers. The two outlines were then superimposed to compare the areas of overlap and nonoverlap. The perimeter of the RPE defect area was calculated by the software in pixels. The superimposed outline of the photoreceptor defect area and the RPE defect area was scrutinized to classify the overlap configuration of the junctional zone into one of three categories: Type 0, exact correspondence between the edge of the RPE defect and photoreceptor defect; Type 1, loss of photoreceptors outside and beyond the edge of the RPE defect; Type 2, preservation of photoreceptors beyond the edge of the RPE defect. The relative proportion of the various border configurations was expressed as a percentage of the perimeter of the RPE defect. Each configuration was then classified into four subgroups according to irregularity of the RPE band and the presence of debris. Fifteen eyes of 11 patients (mean age: 79.3 ± 4.3 years; range: 79-94 years) were included in this study. Seventeen GA lesions were analyzed. Two hundred and thirty-two B-scans were found to pass through the GA lesions, yielding 612 individual GA borders which were separately analyzed and classified. The mean area of the RPE defect was 4.0 ± 4.4 mm, which was significantly smaller than that of the photoreceptor defect which measured 4.4 ± 4.1 mm (paired t test, P = 0.037). On average, 18.0 ± 9.6% (range, 2.3-36.6%) of the junctional zone was of the Type 0 configuration, 57.3 ± 19.0% (range, 21.3-96.8%) was Type 1, and 24.7 ± 18.0% (range, 0.9-64.4%) was Type 2. Type 1 was more prevalent than Type 0 and 2 (analysis of variance, P = 0.000). Debris was present at the margin of the defect in 24.3% (149 of 612) of all assessed junctional zones; 20.0% (14 of 70) of Type 0 junctions, 28.7% (120 of 418) of Type 1, and 12.1% (15 of 124) of Type 2. Debris was more common in Type 1 than Type 2 junctions (P < 0.001). Retinal pigment epithelial irregularity was present at the margin of the defect in 34.8% (213 of 612) of all assessed junctional zones; 52.9% (37 of 70) of Type 0 junctions, 38.0% (159 of 418) of Type 1, and 13.7% (17 of 124) of Type 2. Retinal pigment epithelial irregularity was present more often at Type 0 and Type 1 than at Type 2 junctions (P < 0.001 for both). The size of the optical coherence tomography-visible RPE and photoreceptor defect in GA lesions differ significantly. There were significant areas where the photoreceptor outer segments were preserved despite the absence of visible RPE cells, and also areas of photoreceptor outer segment loss despite apparent RPE preservation. These findings have implications for development of therapeutic strategies, particularly cell-replacement approaches.
Florea, Simona Mihaela; Faure, Alice; Brunel, Hervé; Girard, Nadine; Scavarda, Didier
2018-06-01
The embryological development of the central nervous system takes place during the neurulation process, which includes primary and secondary neurulation. A new form of dysraphism, named junctional neural tube defect (JNTD), was recently reported, with only 4 cases described in the literature. The authors report a fifth case of JNTD. This 5-year-old boy, who had been operated on during his 1st month of life for a uretero-rectal fistula, was referred for evaluation of possible spinal dysraphism. He had urinary incontinence, clubfeet, and a history of delayed walking ability. MRI showed a spinal cord divided in two, with an upper segment ending at the T-11 level and a lower segment at the L5-S1 level, with a thickened filum terminale. The JNTDs represent a recently classified dysraphism caused by an error during junctional neurulation. The authors suggest that their patient should be included in this category as the fifth case reported in the literature and note that this would be the first reported case of JNTD in association with a lipomatous filum terminale.
Hennebicq, Emmanuelle; Deleener, Caroline; Brédas, Jean-Luc; Scholes, Gregory D; Beljonne, David
2006-08-07
The influence of chemical defects and conformational kinks on the nature of the lowest electronic excitations in phenylenevinylene-based polymers is assessed at the semiempirical quantum-chemical level. The amount of excited-state localization and the amplitude of through-space (Coulomb-like) versus through-bond (charge-transfer-like) interactions have been quantified by comparing the results provided by excitonic and supermolecular models. While excitation delocalization among conjugated segments delineated by the defects occurs in the acceptor configuration, self-confinement on individual chromophores follows from geometric relaxation in the excited-state donor configuration. The extent of excited-state localization is found to be sensitive to both the nature of the defect and the length of the conjugated chains. Implications for resonant energy transfer along conjugated polymer chains are discussed.
Reconstruction of Canine Mandibular Bone Defects Using a Bone Transport Reconstruction Plate
Elsalanty, Mohammed E.; Zakhary, Ibrahim; Akeel, Sara; Benson, Byron; Mulone, Timothy; Triplett, Gilbert R.; Opperman, Lynne A.
2010-01-01
Objectives Reconstruction of mandibular segmental bone defects is a challenging task. This study tests a new device used for reconstructing mandibular defects based on the principle of bone transport distraction osteogenesis. Methods Thirteen beagle dogs were divided into control and experimental groups. In all animals, a 3 cm defect was created on one side of the mandible. In eight control animals, the defect was stabilized with a reconstruction plate without further reconstruction and the animals were sacrificed two to three months after surgery. The remaining five animals were reconstructed with a bone transport reconstruction plate (BTRP), comprising a reconstruction plate with attached intraoral transport unit, and were sacrificed after one month of consolidation. Results Clinical evaluation, cone-beam CT densitometry, three-dimensional histomorphometry, and docking site histology revealed significant new bone formation within the defect in the distracted group. Conclusion The physical dimensions and architectural parameters of the new bone were comparable to the contralateral normal bone. Bone union at the docking site remains a problem. PMID:19770704
Bouloy, Michèle; Janzen, Christian; Vialat, Pierre; Khun, Huot; Pavlovic, Jovan; Huerre, Michel; Haller, Otto
2001-01-01
Rift Valley fever virus (RVFV), a phlebovirus of the family Bunyaviridae, is a major public health threat in Egypt and sub-Saharan Africa. The viral and host cellular factors that contribute to RVFV virulence and pathogenicity are still poorly understood. All pathogenic RVFV strains direct the synthesis of a nonstructural phosphoprotein (NSs) that is encoded by the smallest (S) segment of the tripartite genome and has an undefined accessory function. In this report, we show that MP12 and clone 13, two attenuated RVFV strains with mutations in the NSs gene, were highly virulent in IFNAR−/− mice lacking the alpha/beta interferon (IFN-α/β) receptor but remained attenuated in IFN-γ receptor-deficient mice. Both attenuated strains proved to be excellent inducers of early IFN-α/β production. In contrast, the virulent strain ZH548 failed to induce detectable amounts of IFN-α/β and replicated extensively in both IFN-competent and IFN-deficient mice. Clone 13 has a defective NSs gene with a large in-frame deletion. This defect in the NSs gene results in expression of a truncated protein which is rapidly degraded. To investigate whether the presence of the wild-type NSs gene correlated with inhibition of IFN-α/β production, we infected susceptible IFNAR−/− mice with S gene reassortant viruses. When the S segment of ZH548 was replaced by that of clone 13, the resulting reassortants became strong IFN inducers. When the defective S segment of clone 13 was exchanged with the wild-type S segment of ZH548, the reassortant virus lost the capacity to stimulate IFN-α/β production. These results demonstrate that the ability of RVFV to inhibit IFN-α/β production correlates with viral virulence and suggest that the accessory protein NSs is an IFN antagonist. PMID:11152510
Zhang, Peng; Hu, Xudong; Yue, Jinbo; Meng, Xue; Han, Dali; Sun, Xindong; Yang, Guoren; Wang, Shijiang; Wang, Xiaohui; Yu, Jinming
2015-05-01
The primary aim of this prospective study was to investigate the value of (99m)Tc-methoxyisobutylisonitrile (MIBI) single photon emission computed tomography (SPECT) gated myocardial perfusion imaging (GMPI) in the detection of radiation-induced heart disease (RIHD) as early as during radiotherapy (RT) for oesophageal cancer (EC). The second aim was to analyse the correlation between cardiac toxicity and the dose-volume factors. The (99m)Tc-MIBI SPECT GMPI was performed both pre-RT and during RT (40Gray). The results of the SPECT were quantitatively analysed with QGS/QPS software and read by two experienced nuclear medicine physicians. The correlation between the changes in the SPECT parameters and the RT dosimetric data was analysed. Eighteen patients with locally advanced EC were enrolled in the study. Compared with the baseline, the imaging during RT showed not only significant decreases in the wall motion (WM) (1/20 segments), wall thickening (WT) (2/20 segments), end-diastolic perfusion (EDP) (5/20 segments) and end-systolic perfusion (ESP) (8/20 segments) (p<0.05) but also a significant increase in the heart rate (74.63±7.79 vs 81.49±9.90, p=0.036). New myocardial perfusion defects were observed in 8 of the 18 patients. The V37-V40 was significantly higher (p<0.05) in the patients with the new perfusion defects during RT than in the patients who did not exhibit these defects. Radiotherapy for EC induces cardiac damage from an early stage. (99m)Tc-MIBI SPECT GMPI can detect the occurrence of cardiac impairment during RT. The WM, WT, EDP and ESP may be valuable as early indicators of RIHD. The percentage of the heart volume that receives a high dose is an important factor that is correlated with RIHD. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Biswas, Shankar K; Sarai, Masayoshi; Yamada, Akira; Toyama, Hiroshi; Motoyama, Sadako; Harigaya, Hiroto; Hara, Tomonori; Naruse, Hiroyuki; Hishida, Hitoshi; Ozaki, Yukio
2010-02-01
The evolution of the oxidative metabolism of (11)C acetate parallels the recovery of left ventricular(LV) contraction following acute myocardial infarction(AMI). This study was designed to unravel, for the first time, the impact of the global washout rate(WR) of (123)I-beta-methyl-p-iodophenylpentadecanoic acid (BMIPP) on the recovery of LV function followingAMI, as evidenced from conventional echocardiography.Twenty consecutive patients (age: 58 +/- 13 years; 16 males and 4 females) with ST-segment elevation myocardial infarction (STEMI) were enrolled and all of them underwent successful percutaneous coronary intervention (PCI). (123)I-BMIPP cardiac scintigraphy was performed at 7 +/- 3 days after admission. The WR was calculated from the polar map and the regional BMIPP defect score was calculated using a 17 segment model. Echocardiography was performed within 24 h of admission and at 3 months to record the ejection fraction (EF), the wall motion score index (WMSI), the ratio of the mitralinflow velocity to the early diastolic velocity (E/E0)and the myocardial performance index (MPI). The mean global WR of the BMIPP was 22.12 +/- 7.22%, and it was significantly correlated with the improvement of the WMSI (r = 0.61, P\\0.004). However,the relative changes of the EF, E/E0 and MPI were not correlated with the WR. The BMIPP defect score (18 +/- 10) was significantly correlated with the WMSI on admission (r = 0.74, P = 0.0002), but the defect score was not correlated with the relative changes of any of the echocardiographic parameters. We proved that the WR of the BMIPP is a promising indicator of improvement of the LV wall motion (WMSI) following ST-segment elevation myocardial infarction and successful reperfusion.
Enhanced Bone Formation in Segmental Defects with BMP2 in a Biologically Relevant Molecular Context
2016-10-16
gun shots . These do not heal on their own once a ‘critical size’ segment of bone is missing. One strategy to induce healing is to use bone-inducing...accelerate BMP2-induced bone formation by presenting the growth factor in a more biologically relevant context. This is based on our observation...that manganese increases the binding of BMP2 to COMP. The next steps are to validate these observations using BMP2:COMP on HA/PLG scaffolds in-vitro
Enhanced Healing of Segmental Bone Defects by Modulation of the Mechanical Environment
2012-10-01
5.5 µg BMP-2, it was largely disorganized, woven bone with non-osseous soft tissue interspersed. The highest 4 dose (11 µg) of BMP-2, in contrast...various doses of BMP-2. Top row: 16x magnification Bottom row: 100x magnification N= new cortex M= marrow T=trabecular bone F= fibrous tissue ...areas of cartilagenous tissue (figure 5) it was clear that substantial areas of cartilage remained in the defects treated with 5.5 µg BMP-2. These may
Lethal Progressive Thoracic Insufficiency in a Neonate Due to Jarcho Levin Syndrome
Bhutia, Euden; Maria, Arti; Verma, Arushi; Sethi, Sidharth Kumar
2014-01-01
A rare case of Jarcho Levin syndrome (JLS) presenting as a lethal progressive respiratory insufficiency in early neonatal period is reported. The neonate had classical features of this syndrome including vertebral segmentation defects, typical costo-vertebral fusion defects and scoliosis resulting in small thoracic volume and limited chest expansion; all consistent with a clinical diagnosis of JLS with thoracic insufficiency. In addition, our case had a rare association of dextrocardia and acyanotic congenital heart disease. PMID:24741543
2014-10-01
spacer placed at the time of the “Pre-Procedure”. Autogenous Cancellous Bone Graft (ACBG harvested from the sternum at the time of the treatment...will receive more specialized training and orientation to microCT analysis, both on a theoretical and practical level. He will work with raw CT...adjacent to the PMMA) composed of mononuclear cells and exhibited extensive, diffuse fibrous connective tissue. Performed histology on goat autogenous
2014-10-01
initiated. One such fixator has been tested on a cadaveric sheep tibia. In the unlocked, loose position, the axial stiffness of the tibia and fixator...suggested by our previous studies using rats. This aspect of the project is the present focus of attention, and additional cadaver legs will be tested...characterize external fixators). A 3 mm tibial defect was created in the leg of a cadaveric sheep, and stabilized with an experimental external
49 CFR 195.230 - Welds: Repair or removal of defects.
Code of Federal Regulations, 2012 CFR
2012-10-01
... adversely affect the quality of the weld repair. After repair, the segment of the weld that was repaired... welding procedure used to make the original weld are met upon completion of the final weld repair. [Amdt...
49 CFR 195.230 - Welds: Repair or removal of defects.
Code of Federal Regulations, 2014 CFR
2014-10-01
... adversely affect the quality of the weld repair. After repair, the segment of the weld that was repaired... welding procedure used to make the original weld are met upon completion of the final weld repair. [Amdt...
49 CFR 195.230 - Welds: Repair or removal of defects.
Code of Federal Regulations, 2011 CFR
2011-10-01
... adversely affect the quality of the weld repair. After repair, the segment of the weld that was repaired... welding procedure used to make the original weld are met upon completion of the final weld repair. [Amdt...
49 CFR 195.230 - Welds: Repair or removal of defects.
Code of Federal Regulations, 2013 CFR
2013-10-01
... adversely affect the quality of the weld repair. After repair, the segment of the weld that was repaired... welding procedure used to make the original weld are met upon completion of the final weld repair. [Amdt...
49 CFR 195.230 - Welds: Repair or removal of defects.
Code of Federal Regulations, 2010 CFR
2010-10-01
... adversely affect the quality of the weld repair. After repair, the segment of the weld that was repaired... welding procedure used to make the original weld are met upon completion of the final weld repair. [Amdt...
Dual-threshold segmentation using Arimoto entropy based on chaotic bee colony optimization
NASA Astrophysics Data System (ADS)
Li, Li
2018-03-01
In order to extract target from complex background more quickly and accurately, and to further improve the detection effect of defects, a method of dual-threshold segmentation using Arimoto entropy based on chaotic bee colony optimization was proposed. Firstly, the method of single-threshold selection based on Arimoto entropy was extended to dual-threshold selection in order to separate the target from the background more accurately. Then intermediate variables in formulae of Arimoto entropy dual-threshold selection was calculated by recursion to eliminate redundant computation effectively and to reduce the amount of calculation. Finally, the local search phase of artificial bee colony algorithm was improved by chaotic sequence based on tent mapping. The fast search for two optimal thresholds was achieved using the improved bee colony optimization algorithm, thus the search could be accelerated obviously. A large number of experimental results show that, compared with the existing segmentation methods such as multi-threshold segmentation method using maximum Shannon entropy, two-dimensional Shannon entropy segmentation method, two-dimensional Tsallis gray entropy segmentation method and multi-threshold segmentation method using reciprocal gray entropy, the proposed method can segment target more quickly and accurately with superior segmentation effect. It proves to be an instant and effective method for image segmentation.
Bilateral anterior segment dysgenesis with the presumed Peters' anomaly in a cat.
Park, Sangwan; Kim, Kiwoong; Kim, Youngbeum; Seo, Kangmoon
2018-02-20
A seven-month-old female domestic shorthaired cat was presented for buphthalmos in the right eye and corneal cloudiness in the left eye. Full ophthalmic examinations were performed for both eyes and enucleation was done for the right nonvisual eye. Congenital glaucoma caused by anterior segment dysgenesis was confirmed for the right eye. In the left eye, slit-lamp examination revealed focal corneal edema with several iris strands from iris collarette to the affected posterior corneal surfaces. Circular posterior corneal defect was suggested to be the cause of edema. Goniodysgenesis, additionally, was identified. Taken together, the diagnosis of Peters' anomaly which is a subtype of anterior segment dysgenesis was suggested in the left eye.
Wang, Dong; Yang, Zhuang-qun; Hu, Xiao-yi
2007-08-01
To analyze the stress and displacement distribution of 3D-FE models in three conjunctive methods of vascularized iliac bone graft for established mandibular body defects. Using computer image process technique, a series of spiral CT images were put into Ansys preprocess programe to establish three 3D-FE models of different conjunctions. The three 3D-FE models of established mandibular body defects by vascularized iliac bone graft were built up. The distribution of Von Mises stress and displacement around mandibular segment, grafted ilium, plates and screws was obtained. It may be determined successfully that the optimal conjunctive shape be the on-lay conjunction.
Development of a Novel Segmental Bone Defect Construct
2016-10-01
from chicken egg white (90%) were purchased from Sigma Aldrich (St. Louis, MO). Ethylene glycol, sodium metabisulfite (SMS), urea, and hydrogen...HRP-conjugated polyclonal anti-LYZ (chicken egg white) was purchased from United States Biological (Swampscott, MA). N-(3-Sulfopropyl)- N
Ballif, Blake C.; Theisen, Aaron; Rosenfeld, Jill A.; Traylor, Ryan N.; Gastier-Foster, Julie; Thrush, Devon Lamb; Astbury, Caroline; Bartholomew, Dennis; McBride, Kim L.; Pyatt, Robert E.; Shane, Kate; Smith, Wendy E.; Banks, Valerie; Gallentine, William B.; Brock, Pamela; Rudd, M. Katharine; Adam, Margaret P.; Keene, Julia A.; Phillips, John A.; Pfotenhauer, Jean P.; Gowans, Gordon C.; Stankiewicz, Pawel; Bejjani, Bassem A.; Shaffer, Lisa G.
2010-01-01
Segmental duplications, which comprise ∼5%–10% of the human genome, are known to mediate medically relevant deletions, duplications, and inversions through nonallelic homologous recombination (NAHR) and have been suggested to be hot spots in chromosome evolution and human genomic instability. We report seven individuals with microdeletions at 17q23.1q23.2, identified by microarray-based comparative genomic hybridization (aCGH). Six of the seven deletions are ∼2.2 Mb in size and flanked by large segmental duplications of >98% sequence identity and in the same orientation. One of the deletions is ∼2.8 Mb in size and is flanked on the distal side by a segmental duplication, whereas the proximal breakpoint falls between segmental duplications. These characteristics suggest that NAHR mediated six out of seven of these rearrangements. These individuals have common features, including mild to moderate developmental delay (particularly speech delay), microcephaly, postnatal growth retardation, heart defects, and hand, foot, and limb abnormalities. Although all individuals had at least mild dysmorphic facial features, there was no characteristic constellation of features that would elicit clinical suspicion of a specific disorder. The identification of common clinical features suggests that microdeletions at 17q23.1q23.2 constitute a novel syndrome. Furthermore, the inclusion in the minimal deletion region of TBX2 and TBX4, transcription factors belonging to a family of genes implicated in a variety of developmental pathways including those of heart and limb, suggests that these genes may play an important role in the phenotype of this emerging syndrome. PMID:20206336
Horsch, Marion; Beckers, Johannes; Fuchs, Helmut; Gailus-Durner, Valérie; Hrabě de Angelis, Martin; Rathkolb, Birgit; Wolf, Eckhard; Aigner, Bernhard; Kemter, Elisabeth
2014-01-01
Uromodulin-associated kidney disease (UAKD) is a hereditary progressive renal disease which can lead to renal failure and requires renal replacement therapy. UAKD belongs to the endoplasmic reticulum storage diseases due to maturation defect of mutant uromodulin and its retention in the enlarged endoplasmic reticulum in the cells of the thick ascending limb of Henle's loop (TALH). Dysfunction of TALH represents the key pathogenic mechanism of UAKD causing the clinical symptoms of this disease. However, the molecular alterations underlying UAKD are not well understood. In this study, transcriptome profiling of whole kidneys of two mouse models of UAKD, UmodA227T and UmodC93F, was performed. Genes differentially abundant in UAKD affected kidneys of both Umod mutant lines at different disease stages were identified and verified by RT-qPCR. Additionally, differential protein abundances of SCD1 and ANGPTL7 were validated by immunohistochemistry and Western blot analysis. ANGPTL7 expression was down-regulated in TALH cells of Umod mutant mice which is the site of the mutant uromodulin maturation defect. SCD1 was expressed selectively in the S3 segment of proximal tubule cells, and SCD1 abundance was increased in UAKD affected kidneys. This finding demonstrates that a cross talk between two functionally distinct tubular segments of the kidney, the TALH segment and the S3 segment of proximal tubule, exists.
Zhang, Ya-Dong; Wang, Gang; Sun, Yan; Zhang, Chang-Qing
2011-02-01
Porous scaffold biomaterials may offer a clinical alternative to bone grafts; however, scaffolds alone are typically insufficient to heal large bone defects. Numerous studies have demonstrated that osteoinductive growth factor significantly improves bone repair. In this study, a strategy combining degradable bioactive borate glass (BG) scaffolds with platelet-rich plasma (PRP) was tested. The bone defect was filled with BG alone, BG combined with autologous PRP or left empty. Bone formation was analyzed at 4, 8 and 12 weeks using both histology and radiology. The PRP treated group yielded better bone formation than the pure BG scaffold as determined by both histology and microcomputer tomography after 12 weeks. In conclusion, PRP improved bone healing in a diaphyseal rabbit model on BG. The combination of PRP and BG may be an effective approach to repair critical defects.
Lee, Jung Min; Kim, Ji Heui; Lee, Ok Joo; Park, Chan Hum
2013-06-01
Bioresorbable fixation systems have been popular for the treatment of facial fractures. However, their mechanical properties are uncertain and complications have been reported. To overcome these problems, we developed a bioresorbable fixation plate using a composite of silk fibroin and bacterial cellulose (SF-BC) with biodegradability and increased biocompatibility. To investigate the regenerative effect of the bioresorbable SF-BC fixation plate on zygomatic arch defects in rats. In vivo animal study. The SF-BC composite plate had a tensile strength similar to that of a polylactic acid plate and a tight, pore-free microstructure. Bilateral segmental bone defects (2 mm in length) were created in the zygomatic arches of adult rats. One side was fixed with the SF-BC composite plate, and the other side was left without fixation. Academic research laboratory. Fifteen adult Sprague-Dawley rats. Fixation of the zygomatic arch defect with the SF-BC composite plate. Micro-computed tomography and histological evaluation of bone samples. Gross inspection revealed no specific complication. At 1, 2, 4, and 8 postoperative weeks, the zygomatic arches were explored by micro-computed tomography and histological examination. Control sides did not heal completely and showed bony degeneration and necrosis during the 8-week follow-up. However, we observed new bone formation in sides treated with the SF-BC composite plate, and bony defects were completely healed within 8 weeks. The SF-BC composite plate is a potential candidate for a new bioresorbable fixation system. Our composite material could considerably shorten bone regeneration time. Additional study of the control of biodegradability and mechanical properties of SF-BC composite plates and a comparative study with the resorbable plates currently in use should be undertaken.
Zara, Janette N; Siu, Ronald K; Zhang, Xinli; Shen, Jia; Ngo, Richard; Lee, Min; Li, Weiming; Chiang, Michael; Chung, Jonguk; Kwak, Jinny; Wu, Benjamin M; Ting, Kang; Soo, Chia
2011-05-01
The major Food and Drug Association-approved osteoinductive factors in wide clinical use are bone morphogenetic proteins (BMPs). Although BMPs can promote robust bone formation, they also induce adverse clinical effects, including cyst-like bone formation and significant soft tissue swelling. In this study, we evaluated multiple BMP2 doses in a rat femoral segmental defect model and in a minimally traumatic rat femoral onlay model to determine its dose-dependent effects. Results of our femoral segmental defect model established a low BMP2 concentration range (5 and 10 μg/mL, total dose 0.375 and 0.75 μg in 75 μg total volume) unable to induce defect fusion, a mid-range BMP2 concentration range able to fuse the defect without adverse effects (30 μg/mL, total dose 2.25 μg in 75 μg total volume), and a high BMP2 concentration range (150, 300, and 600 μg/mL, total dose 11.25, 22.5, and 45 μg in 75 μg total volume) able to fuse the defect, but with formation of cyst-like bony shells filled with histologically confirmed adipose tissue. In addition, compared to control, 4 mg/mL BMP2 also induced significant tissue inflammatory infiltrates and exudates in the femoral onlay model that was accompanied by increased numbers of osteoclast-like cells at 3, 7, and 14 days. Overall, we consistently reproduced BMP2 side effects of cyst-like bone and soft tissue swelling using high BMP2 concentration approaching the typical human 1500 μg/mL.
Uckun, Fatih M.; Qazi, Sanjive; Ma, Hong; Reaman, Gregory H.; Mitchell, Lloyd G.
2015-01-01
Our recent studies have demonstrated that the CD22 exon 12 deletion (CD22ΔE12) is a characteristic genetic defect of therapy-refractory clones in pediatric B-precursor acute lymphoblastic leukemia (BPL) and implicated the CD22ΔE12 genetic defect in the aggressive biology of relapsed or therapy-refractory pediatric BPL. The purpose of the present study was to further evaluate the biologic significance of the CD22ΔE12 molecular lesion and determine if it could serve as a molecular target for corrective repair using RNA trans-splicing therapy. We show that both pediatric and adult B-lineage lymphoid malignancies are characterized by a very high incidence of the CD22ΔE12 genetic defect. We provide experimental evidence that the correction of the CD22ΔE12 genetic defect in human CD22ΔE12+ BPL cells using a rationally designed CD22 RNA trans-splicing molecule (RTM) caused a pronounced reduction of their clonogenicity. The RTM-mediated correction replaced the downstream mutation-rich segment of Intron 12 and remaining segments of the mutant CD22 pre-mRNA with wildtype CD22 Exons 10-14, thereby preventing the generation of the cis-spliced aberrant CD22ΔE12 product. The anti-leukemic activity of this RTM against BPL xenograft clones derived from CD22ΔE12+ leukemia patients provides the preclinical proof-of-concept that correcting the CD22ΔE12 defect with rationally designed CD22 RTMs may provide the foundation for therapeutic innovations that are needed for successful treatment of high-risk and relapsed BPL patients. PMID:25567759
Zara, Janette N.; Siu, Ronald K.; Zhang, Xinli; Shen, Jia; Ngo, Richard; Lee, Min; Li, Weiming; Chiang, Michael; Chung, Jonguk; Kwak, Jinny; Wu, Benjamin M.; Ting, Kang
2011-01-01
The major Food and Drug Association–approved osteoinductive factors in wide clinical use are bone morphogenetic proteins (BMPs). Although BMPs can promote robust bone formation, they also induce adverse clinical effects, including cyst-like bone formation and significant soft tissue swelling. In this study, we evaluated multiple BMP2 doses in a rat femoral segmental defect model and in a minimally traumatic rat femoral onlay model to determine its dose-dependent effects. Results of our femoral segmental defect model established a low BMP2 concentration range (5 and 10 μg/mL, total dose 0.375 and 0.75 μg in 75 μg total volume) unable to induce defect fusion, a mid-range BMP2 concentration range able to fuse the defect without adverse effects (30 μg/mL, total dose 2.25 μg in 75 μg total volume), and a high BMP2 concentration range (150, 300, and 600 μg/mL, total dose 11.25, 22.5, and 45 μg in 75 μg total volume) able to fuse the defect, but with formation of cyst-like bony shells filled with histologically confirmed adipose tissue. In addition, compared to control, 4 mg/mL BMP2 also induced significant tissue inflammatory infiltrates and exudates in the femoral onlay model that was accompanied by increased numbers of osteoclast-like cells at 3, 7, and 14 days. Overall, we consistently reproduced BMP2 side effects of cyst-like bone and soft tissue swelling using high BMP2 concentration approaching the typical human 1500 μg/mL. PMID:21247344
Virgincar, Rohan S.; Cleveland, Zackary I.; Kaushik, S. Sivaram; Freeman, Matthew S.; Nouls, John; Cofer, Gary P.; Martinez-Jimenez, Santiago; He, Mu; Kraft, Monica; Wolber, Jan; McAdams, H. Page; Driehuys, Bastiaan
2013-01-01
In this study, hyperpolarized (HP) 129Xe MR ventilation and 1H anatomical images were obtained from 3 subject groups: young healthy volunteers (HV), subjects with chronic obstructive pulmonary disease (COPD), and age-matched control subjects (AMC). Ventilation images were quantified by 2 methods: an expert reader-based ventilation defect score percentage (VDS%) and a semi-automatic segmentation-based ventilation defect percentage (VDP). Reader-based values were assigned by two experienced radiologists and resolved by consensus. In the semi-automatic analysis, 1H anatomical images and 129Xe ventilation images were both segmented following registration, to obtain the thoracic cavity volume (TCV) and ventilated volume (VV), respectively, which were then expressed as a ratio to obtain the VDP. Ventilation images were also characterized by generating signal intensity histograms from voxels within the TCV, and heterogeneity was analyzed using the coefficient of variation (CV). The reader-based VDS% correlated strongly with the semi-automatically generated VDP (r = 0.97, p < 0.0001), and with CV (r = 0.82, p < 0.0001). Both 129Xe ventilation defect scoring metrics readily separated the 3 groups from one another and correlated significantly with FEV1 (VDS%: r = -0.78, p = 0.0002; VDP: r = -0.79, p = 0.0003; CV: r = -0.66, p = 0.0059) and other pulmonary function tests. In the healthy subject groups (HV and AMC), the prevalence of ventilation defects also increased with age (VDS%: r = 0.61, p = 0.0002; VDP: r = 0.63, p = 0.0002). Moreover, ventilation histograms and their associated CVs distinguished between COPD subjects with similar ventilation defect scores but visibly different ventilation patterns. PMID:23065808
The anterior segment disorder autosomal dominant keratitis is linked to the Aniridia/PAX-6 gene
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mirzayans, F.; Pearce, W.G.; Mah, T.S.
1994-09-01
Autosomal dominant keratitis (ADK) is an eye disease characterized by anterior stromal corneal opacification and vascularization in the peripheral cornea. Progression into the central cornea may compromise visual acuity. Other anterior segment features include minimal radial defects of the iris stroma. Posterior segment involvement is characterized by foveal hypoplasia with minimal effect on visual acuity. Aniridia is a second autosomal dominantly inherited ocular disorder defined by structural defects of the iris, frequently severe enough to cause an almost complete absence of iris. This may be accompanied by other anterior segment manifestations, including cataract and keratitis. Posterior segment involvement in aniridiamore » is characterized by foveal hypoplasia resulting in a highly variable impairment of visual acuity, often with nystagmus. Aniridia is usually inherited as an autosomal dominant disease and occurs in 1 in 50,000 to 100,000 people. Aniridia has been shown to result from mutations in PAX-6, a gene thought to regulate fetal eye development. The similar clinical findings in ADK and aniridia, with the similar patterns of inheritance, compelled us to investigate if these two ocular disorders are variants of the same genetic disorder. We have tested for linkage between PAX-6 and ADK within an ADK family with 33 members over four generations, including 11 affected individuals. Linkage studies reveal that D11S914 (located within 3 cM of PAX-6) does not recombine with ADK (LOD score 3.61; {theta} = 0.00), consistent with PAX-6 mutations being responsible for ADK. Direct sequencing of PAX-6 RT-PCR products from ADK patients is underway to identify the mutation within the PAX-6 gene that results in ADK. The linkage of PAX-6 with ADK, along with a recent report that mutations in PAX-6 also underlie Peter`s anomaly, implicates PAX-6 widely in anterior segment malformations.« less
Eason, Jessica; Williams, Antionette L; Chawla, Bahaar; Apsey, Christian; Bohnsack, Brenda L
2017-09-01
Ethanol (ETOH) exposure during pregnancy is associated with craniofacial and neurologic abnormalities, but infrequently disrupts the anterior segment of the eye. In these studies, we used zebrafish to investigate differences in the teratogenic effect of ETOH on craniofacial, periocular, and ocular neural crest. Zebrafish eye and neural crest development was analyzed by means of live imaging, TUNEL (terminal deoxynucleotidyl transferase dUTP nick end labeling) assay, immunostaining, detection of reactive oxygen species, and in situ hybridization. Our studies demonstrated that foxd3-positive neural crest cells in the periocular mesenchyme and developing eye were less sensitive to ETOH than sox10-positive craniofacial neural crest cells that form the pharyngeal arches and jaw. ETOH increased apoptosis in the retina, but did not affect survival of periocular and ocular neural crest cells. ETOH also did not increase reactive oxygen species within the eye. In contrast, ETOH increased ventral neural crest apoptosis and reactive oxygen species production in the facial mesenchyme. In the eye and craniofacial region, sod2 showed high levels of expression in the anterior segment and in the setting of Sod2 knockdown, low levels of ETOH decreased migration of foxd3-positive neural crest cells into the developing eye. However, ETOH had minimal effect on the periocular and ocular expression of transcription factors (pitx2 and foxc1) that regulate anterior segment development. Neural crest cells contributing to the anterior segment of the eye exhibit increased ability to withstand ETOH-induced oxidative stress and apoptosis. These studies explain the rarity of anterior segment dysgenesis despite the frequent craniofacial abnormalities in fetal alcohol syndrome. Birth Defects Research 109:1212-1227, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Repair of segmental bone defects with bone marrow and BMP-2 adenovirus in the rabbit radius
NASA Astrophysics Data System (ADS)
Cheng, Lijia; Lu, Xiaofeng; Shi, Yujun; Li, Li; Xue, Jing; Zhang, Li; Xia, Jie; Wang, Yujia; Zhang, Xingdong; Bu, Hong
2012-12-01
Bone tissue engineering (BTE) is approached via implantation of autogenous mesenchymal stem cells (MSCs), marrow cells, or platelet-rich plasma, etc. To the contrary, gene therapy combining with the bone marrow (BM) has not been often reported. This study was performed to investigate whether a modified BTE method, that is, the BM and a recombinant human bone morphogenetic protein-2 adenovirus (Ad.hBMP-2) gene administering in hydroxyapatite/β-tricalcium phosphate (HA/β-TCP) ceramics could accelerate the healing of segmental defects in the rabbit radius. In our study, ceramics were immersed in the adenovirus overnight, and half an hour before surgery, autologous BM aspirates were thoroughly mixed with the ceramics; at the same time, a 15-mm radius defect was introduced in the bilateral forelimbs of all animals, after that, this defect was filled with the following: (1) Ad.hBMP-2 + HA/β-TCP + autologous BM (group 1); (2) HA/β-TCP + Ad.hBMP-2 (group 2); (3) HA/β-TCP alone (group 3); (4) an empty defect as a control (group 4). Histological observation and μ-CT analyses were performed on the specimens at weeks 2, 4, 8, and 12, respectively. In group 1, new bone was observed at week 4 and BM appeared at week 12, in groups 2 and 3, new bone was observed at week 8 and it was more mature at week 12, in contrast, the defect was not bridged in group 4 at week 12. The new bone area percentage in group 1 was significantly higher than that in groups 2 and 3. Our study indicated that BM combined with hBMP-2 adenovirus and porous ceramics could significantly increase the amount of newly formed bone. And this modified BTE method thus might have potentials in future clinical application.
The Use of Harmonic Scalpel for Free Flap Dissection in Head and Neck Reconstructive Surgery
Albert, Sebastien; Guedon, Charles; Halimi, Caroline; Cristofari, Jean Pierre; Barry, Beatrix
2012-01-01
Surgeons conventionally use electrocautery dissection and surgical clip appliers to harvest free flaps. The ultrasonic Harmonic Scalpel is a new surgical instrument that provides high-quality dissection and hemostasis and minimizes tissue injury. The aim of this study was to evaluate the effectiveness and advantages of the ultrasonic Harmonic Scalpel compared to conventional surgical instruments in free flap surgery. This prospective study included 20 patients who underwent head and neck reconstructive surgery between March 2009 and May 2010. A forearm free flap was used for reconstruction in 12 patients, and a fibular flap was used in 8 patients. In half of the patients, electrocautery and surgical clips were used for free flap harvesting (the EC group), and in the other half of the patients, ultrasonic dissection was performed using the Harmonic Scalpel (the HS group). The following parameters were significantly lower in the HS group compared to the EC group: the operative time of flap dissection (35% lower in the HS group), blood loss, number of surgical clips and cost of surgical materials. This study demonstrated the effectiveness of the Harmonic Scalpel in forearm and fibular free flap dissections that may be extended to other free flaps. PMID:22693666
Addosooki, Ahmad I; El-deen, Mohamed Alam
2015-01-01
Purpose A retrospective study to compare the radiologic and clinical outcomes of 2 different anterior approaches, multilevel anterior cervical discectomy with fusion (ACDF) using autologus ticortical bone graft versus anterior cervical corpectomy with fusion (ACCF) using free vascularized fibular graft (FVFG) for the management of cervical spondylotic myelopathy(CSM). Methods A total of 15 patients who underwent ACDF or ACCF using FVFG for multilevel CSM were divided into two groups. Group A (n = 7) underwent ACDF and group B (n = 8) ACCF. Clinical outcomes using Japanese Orthopaedic Association (JOA) score, perioperative parameters including operation time and hospital stay, radiological parameters including fusion rate and cervical lordosis, and complications were compared. Results Both group A and group B demonstrated significant increases in JOA scores. Patients who underwent ACDF experienced significantly shorter operation times and hospital stay. Both groups showed significant increases in postoperative cervical lordosis and achieved the same fusion rate (100 %). No major complications were encountered in both groups. Conclusion Both ACDF and ACCF using FVFG provide satisfactory clinical outcomes and fusion rates for multilevel CSM. However, multilevel ACDF is associated with better radiologic parameters, shorter hospital stay and shorter operative times. PMID:26767152
Harvesting the free fibular graft: A modified approach
Mukherjee, Amitava Narayan; Pal, Ananda Kisor; Singharoy, Debashis; Baksi, Debadyuti; Nath, Chinmoy
2011-01-01
Background: The conventional technique of free non-vascularized fibular grafting is attended with some amount of morbidity and a long scar. We report a technique with little interference to the surrounding soft tissues to harvest more than one-third of whole length fibula. Patients and Methods: Thirty four patients of average age 23.5 years (range 8 to 51 years) having various pathologies like simple bone cysts (n=9), fibrous dysplasias (n=6), giant cell tumors (n=7), fracture non-union (n=10) and aneurysmal bone cysts (n=2) were taken up for the study. The fibula were harvested by two separate incisions, 1 cm each at proximal and distal extent of proposed donor site for taking out of graft after elevating the periosteum circumferentially using a periosteum stripper. Compression bandage and above knee plaster immobilization was applied to reduce the dead space collection. Results: The mean followup is 34 months. The patients were evaluated clinicoradiology. Thirty three patients showed good results. One patient had fair result due to delayed wound healing from hematoma which was treated surgically. Conclusion: The approach of harvesting fibula suggested by author reduces donor site morbidity and is safer than conventional approach. PMID:21221224
Laboratory demonstration of an optical vortex mask coronagraph using photonic crystal
NASA Astrophysics Data System (ADS)
Murakami, N.; Baba, N.; Ise, A.; Sakamoto, M.; Oka, K.
2010-10-01
Photonic crystal, artificial periodic nanostructure, is an attractive device for constructing focal-plane phase-mask coronagraphs such as segmented phase masks (four-quadrant, eight-octant, and 4N-segmented ones) and an optical vortex mask (OVM), because of its extremely small manufacturing defect. Recently, speckle-noise limited contrast has been demonstrated for two monochromatic lasers by using the eight-octant phase-mask made of the photonic crystal (Murakami et al. 2010, ApJ, 714, 772). We applied the photonic-crystal device to the OVM coronagraph. The OVM is more advantageous over the segmented phase masks because it does not have discontinuities other than a central singular point and provides a full on-sky field of view. For generating an achromatic optical vortex, we manufactured an axially-symmetric half-wave plate (ASHWP). It is expected that a size of the manufacturing defect due to the central singularity is an order of several hundreds nanometers. The ASHWP is placed between two circular polarizers for modulating a Pancharatnam phase. A continuous spiral phase modulation is then implemented achromatically. We carried out preliminary laboratory demonstration of the OVM coronagraph using two monochromatic lasers as a model star (wavelengths of 532 nm and 633 nm). We report a principle of the achromatic optical-vortex generation, and results of the laboratory demonstration of the OVM coronagraph.
High frequency QRS ECG predicts ischemic defects during myocardial perfusion imaging
NASA Technical Reports Server (NTRS)
2004-01-01
Changes in high frequency QRS components of the electrocardiogram (HF QRS ECG) (150-250 Hz) are more sensitive than changes in conventional ST segments for detecting myocardial ischemia. We investigated the accuracy of 12-lead HF QRS ECG in detecting ischemia during adenosine tetrofosmin myocardial perfusion imaging (MPI). 12-lead HF QRS ECG recordings were obtained from 45 patients before and during adenosine technetium-99 tetrofosmin MPI tests. Before the adenosine infusions, recordings of HF QRS were analyzed according to a morphological score that incorporated the number, type and location of reduced amplitude zones (RAZs) present in the 12 leads. During the adenosine infusions, recordings of HF QRS were analyzed according to the maximum percentage changes (in both the positive and negative directions) that occurred in root mean square (RMS) voltage amplitudes within the 12 leads. The best set of prospective HF QRS criteria had a sensitivity of 94% and a specificity of 83% for correctly identifying the MPI result. The sensitivity of simultaneous ST segment changes (18%) was significantly lower than that of any individual HF QRS criterion (P less than 0.00l). Analysis of 12-lead HF QRS ECG is highly sensitive and specific for detecting ischemic perfusion defects during adenosine MPI stress tests and significantly more sensitive than analysis of conventional ST segments.
High frequency QRS ECG predicts ischemic defects during myocardial perfusion imaging
NASA Technical Reports Server (NTRS)
Rahman, Atiar
2006-01-01
Background: Changes in high frequency QRS components of the electrocardiogram (HF QRS ECG) (150-250 Hz) are more sensitive than changes in conventional ST segments for detecting myocardial ischemia. We investigated the accuracy of 12-lead HF QRS ECG in detecting ischemia during adenosine tetrofosmin myocardial perfusion imaging (MPI). Methods and Results: 12-lead HF QRS ECG recordings were obtained from 45 patients before and during adenosine technetium-99 tetrofosmin MPI tests. Before the adenosine infusions, recordings of HF QRS were analyzed according to a morphological score that incorporated the number, type and location of reduced amplitude zones (RAZs) present in the 12 leads. During the adenosine infusions, recordings of HF QRS were analyzed according to the maximum percentage changes (in both the positive and negative directions) that occurred in root mean square (RMS) voltage amplitudes within the 12 leads. The best set of prospective HF QRS criteria had a sensitivity of 94% and a specificity of 83% for correctly identifying the MPI result. The sensitivity of simultaneous ST segment changes (18%) was significantly lower than that of any individual HF QRS criterion (P<0.001). Conclusions: Analysis of 12-lead HF QRS ECG is highly sensitive and specific for detecting ischemic perfusion defects during adenosine MPI stress tests and significantly more sensitive than analysis of conventional ST segments.
Suska, Felicia; Kjeller, Göran; Tarnow, Peter; Hryha, Eduard; Nyborg, Lars; Snis, Anders; Palmquist, Anders
2016-08-01
In the field of maxillofacial reconstruction, additive manufacturing technologies, specifically electron beam melting (EBM), offer clinicians the potential for patient-customized design of jaw prostheses, which match both load-bearing and esthetic demands. The technique allows an innovative, functional design, combining integrated porous regions for bone ingrowth and secondary biological fixation with solid load-bearing regions ensuring the biomechanical performance. A patient-specific mandibular prosthesis manufactured using EBM was successfully used to reconstruct a patient's mandibular defect after en bloc resection. Over a 9-month follow-up period, the patient had no complications. A short operating time, good esthetic outcome, and high level of patient satisfaction as measured by quality-of-life questionnaires-the European Organisation for Research and Treatment of Cancer QLQ-C30 (30-item quality-of-life core questionnaire) and H&N35 (head and neck cancer module)-were reported for this case. Individually planned and designed EBM-produced prostheses may be suggested as a possible future alternative to fibular grafts or other reconstructive methods. However, the role of porosity, the role of geometry, and the optimal combination of solid and porous parts, as well as surface properties in relation to soft tissues, should be carefully evaluated in long-term clinical trials. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Arthrodesis of the knee with a vascularized fibular rotatory graft.
Rasmussen, M R; Bishop, A T; Wood, M B
1995-05-01
We retrospectively reviewed the records of thirteen patients who had been managed with an arthrodesis of the knee with use of a vascularized graft from the ipsilateral fibula and fixation with an intramedullary rod. The indications for the operation included a large skeletal defect secondary to the resection of a tumor about the knee in eight patients, an infection at the site of an arthroplasty in four (with failure of a previous conventional arthrodesis in three of the four), and severe rheumatoid gonarthrosis as well as a persistent non-union of the distal part of the femur in one. The average age of the patients at the time of the operation was forty-three years (range, twenty-six to seventy-six years). Most of the patients had had multiple previous procedures (thirty-three operations had been performed in ten patients). Twelve of the thirteen patients had a solid fusion and a successful result after an average duration of follow-up of fifty-one months (range, eight to ninety-three months). The remaining patient, who had had four previous arthroplasties, had a recurrence of an infection seven months after the operation and was managed with an amputation. Six complications--including two superficial wound infections, one deep wound infection, one deep venous thrombosis, one transient peroneal-nerve palsy, and one delayed union--occurred in three patients.
Alkaduhimi, Hassanin; van den Bekerom, Michel P J; van Deurzen, Derek F P
2017-06-01
Posterior shoulder dislocations are accompanied by high forces and can result in an anteromedial humeral head impression fracture called a reverse Hill-Sachs lesion. This reverse Hill-Sachs lesion can result in serious complications including posttraumatic osteoarthritis, posterior dislocations, osteonecrosis, persistent joint stiffness, and loss of shoulder function. Treatment is challenging and depends on the amount of bone loss. Several techniques have been reported to describe the surgical treatment of lesions larger than 20%. However, there is still limited evidence with regard to the optimal procedure. Favorable results have been reported by performing segmental reconstruction of the reverse Hill-Sachs lesion with bone allograft. Although the procedure of segmental reconstruction has been used in several studies, its technique has not yet been well described in detail. In this report we propose a step-by-step description of the technique how to perform a segmental reconstruction of a reverse Hill-Sachs defect.
NASA Astrophysics Data System (ADS)
Xiao, Zhitao; Leng, Yanyi; Geng, Lei; Xi, Jiangtao
2018-04-01
In this paper, a new convolution neural network method is proposed for the inspection and classification of galvanized stamping parts. Firstly, all workpieces are divided into normal and defective by image processing, and then the defective workpieces extracted from the region of interest (ROI) area are input to the trained fully convolutional networks (FCN). The network utilizes an end-to-end and pixel-to-pixel training convolution network that is currently the most advanced technology in semantic segmentation, predicts result of each pixel. Secondly, we mark the different pixel values of the workpiece, defect and background for the training image, and use the pixel value and the number of pixels to realize the recognition of the defects of the output picture. Finally, the defect area's threshold depended on the needs of the project is set to achieve the specific classification of the workpiece. The experiment results show that the proposed method can successfully achieve defect detection and classification of galvanized stamping parts under ordinary camera and illumination conditions, and its accuracy can reach 99.6%. Moreover, it overcomes the problem of complex image preprocessing and difficult feature extraction and performs better adaptability.
Vision-based in-line fabric defect detection using yarn-specific shape features
NASA Astrophysics Data System (ADS)
Schneider, Dorian; Aach, Til
2012-01-01
We develop a methodology for automatic in-line flaw detection in industrial woven fabrics. Where state of the art detection algorithms apply texture analysis methods to operate on low-resolved ({200 ppi) image data, we describe here a process flow to segment single yarns in high-resolved ({1000 ppi) textile images. Four yarn shape features are extracted, allowing a precise detection and measurement of defects. The degree of precision reached allows a classification of detected defects according to their nature, providing an innovation in the field of automatic fabric flaw detection. The design has been carried out to meet real time requirements and face adverse conditions caused by loom vibrations and dirt. The entire process flow is discussed followed by an evaluation using a database with real-life industrial fabric images. This work pertains to the construction of an on-loom defect detection system to be used in manufacturing practice.
A Novel Defect Inspection Method for Semiconductor Wafer Based on Magneto-Optic Imaging
NASA Astrophysics Data System (ADS)
Pan, Z.; Chen, L.; Li, W.; Zhang, G.; Wu, P.
2013-03-01
The defects of semiconductor wafer may be generated from the manufacturing processes. A novel defect inspection method of semiconductor wafer is presented in this paper. The method is based on magneto-optic imaging, which involves inducing eddy current into the wafer under test, and detecting the magnetic flux associated with eddy current distribution in the wafer by exploiting the Faraday rotation effect. The magneto-optic image being generated may contain some noises that degrade the overall image quality, therefore, in this paper, in order to remove the unwanted noise present in the magneto-optic image, the image enhancement approach using multi-scale wavelet is presented, and the image segmentation approach based on the integration of watershed algorithm and clustering strategy is given. The experimental results show that many types of defects in wafer such as hole and scratch etc. can be detected by the method proposed in this paper.
Xie, Huanxin; Ji, Ye; Tian, Qi; Wang, Xintao; Zhang, Nan; Zhang, Yicai; Xu, Jun; Wang, Nanxiang; Yan, Jinglong
2017-11-01
To explore the effects of autogenous bone particle/titanium fiber composites on repairing segmental bone defects in rabbits. A model of bilateral radial bone defect was established in 36 New Zealand white rabbits which were randomly divided into 3 groups according to filling materials used for bilaterally defect treatment: in group C, 9 animal bone defect areas were prepared into simple bilateral radius bone defect (empty sham) as the control group; 27 rabbits were used in groups ABP and ABP-Ti. In group ABP, left defects were simply implanted with autogenous bone particles; meanwhile, group ABP-Ti animals had right defects implanted with autogenous bone particle/titanium fiber composites. Animals were sacrificed at 4, 8, and 12 weeks, respectively, after operation. Micro-CT showed that group C could not complete bone regeneration. Bone volume to tissue volume values in group ABP-Ti were better than group ABP. From histology and histomorphometry Groups ABP and ABP-Ti achieved bone repair, the bone formation of group ABP-Ti was better. The mechanical strength of group ABP-Ti was superior to that of other groups. These results confirmed the effectiveness of autologous bone particle/titanium fiber composites for promoting bone regeneration and mechanical strength.
Sparsity guided empirical wavelet transform for fault diagnosis of rolling element bearings
NASA Astrophysics Data System (ADS)
Wang, Dong; Zhao, Yang; Yi, Cai; Tsui, Kwok-Leung; Lin, Jianhui
2018-02-01
Rolling element bearings are widely used in various industrial machines, such as electric motors, generators, pumps, gearboxes, railway axles, turbines, and helicopter transmissions. Fault diagnosis of rolling element bearings is beneficial to preventing any unexpected accident and reducing economic loss. In the past years, many bearing fault detection methods have been developed. Recently, a new adaptive signal processing method called empirical wavelet transform attracts much attention from readers and engineers and its applications to bearing fault diagnosis have been reported. The main problem of empirical wavelet transform is that Fourier segments required in empirical wavelet transform are strongly dependent on the local maxima of the amplitudes of the Fourier spectrum of a signal, which connotes that Fourier segments are not always reliable and effective if the Fourier spectrum of the signal is complicated and overwhelmed by heavy noises and other strong vibration components. In this paper, sparsity guided empirical wavelet transform is proposed to automatically establish Fourier segments required in empirical wavelet transform for fault diagnosis of rolling element bearings. Industrial bearing fault signals caused by single and multiple railway axle bearing defects are used to verify the effectiveness of the proposed sparsity guided empirical wavelet transform. Results show that the proposed method can automatically discover Fourier segments required in empirical wavelet transform and reveal single and multiple railway axle bearing defects. Besides, some comparisons with three popular signal processing methods including ensemble empirical mode decomposition, the fast kurtogram and the fast spectral correlation are conducted to highlight the superiority of the proposed method.
USDA-ARS?s Scientific Manuscript database
Heterotopic ossification (HO), or endochondral bone formation at nonskeletal sites, often results from traumatic injury and can lead to devastating consequences. Alternatively, the ability to harness this phenomenon would greatly enhance current orthopedic tools for treating segmental bone defects. ...
Enhanced Healing of Segmental Bone Defects by Modulation of the Mechanical Environment
2013-10-01
Employment opportunities received based upon experience/ training supported by this award Partly based upon her research during the completion of...School, Coventry CV4 7AL, United Kingdom References 1. Stevenson S. Enhancement of fracture healing with autogenous and allogeneic bone grafts. Clin
Tu, Yiji; Chen, Zenggan; Lineaweaver, William Charles; Zhang, Feng
2017-12-01
Several recipient vessels can be used in free microsurgical fibula flaps (MFFs) for the treatment of avascular necrosis of the femoral head (ANFH). Few articles investigate the influence of different recipient vessels on outcomes of MFF for ANFH. A comprehensive literature search of databases including PubMed-Medline, Ovid-Embase, and Cochrane Library was performed to collect the related studies. The Medical Subject Headings used were "femur head necrosis" and "bone transplantation." The relevant words in title or abstract included but not limited to "fibula flap," "fibular flap," "vascularized fibula," "vascularized fibular," "free fibula," "free fibular," "femoral head necrosis," "avascular necrosis of femoral head," and "ischemic necrosis of femoral head." The methodological index for nonrandomized studies was adopted for assessing the studies included in this review. Finally, 15 studies encompassing a total of 1267 patients (1603 hips) with ANFH were pooled in the overall analysis. Recipient vessels for MFF included the ascending branch of the lateral circumflex femoral artery and vein in 8 studies, descending branch of the lateral circumflex femoral artery and vein in 2 studies, second perforating branch of the deep femoral artery and vein in 4 studies, and inferior gluteal artery and vein in 1 study. Preoperative and postoperative average Harris hip score and pooled analyses of the rate of conversion, radiographic progression, and hip surgery-related complications showed no significant difference on the outcomes of MFF on ANFH between using different recipient vessels. Different recipient vessels did not affect outcomes in MFF procedures for ANFH. High-quality randomized controlled trials and prospective studies would be necessary to clarify reliable advantages and disadvantages between different recipient vessels. Until then, surgeons are justified in using ascending branch of the lateral circumflex femoral artery and vein, descending branch of the lateral circumflex femoral artery and vein, second perforating branch of the deep femoral artery and vein, and inferior gluteal artery and vein vessels according to care circumstances and customary practice.
Anatomy and Histology of the Knee Anterolateral Ligament.
Helito, Camilo Partezani; Demange, Marco Kawamura; Bonadio, Marcelo Batista; Tírico, Luis Eduardo Passarelli; Gobbi, Riccardo Gomes; Pécora, José Ricardo; Camanho, Gilberto Luis
2013-12-01
Reconstruction of the anterior cruciate ligament (ACL) is one of the most common procedures in orthopaedic surgery. However, even with advances in surgical techniques and implants, some patients still have residual anterolateral rotatory laxity after reconstruction. A thorough study of the anatomy of the anterolateral region of the knee is needed. To study the anterolateral region and determine the measurements and points of attachments of the anterolateral ligament (ALL). Descriptive laboratory study. Dissections of the anterolateral structures of the knee were performed in 20 human cadavers. After isolating the ALL, its length, thickness, width, and points of attachments were determined. The femoral attachment of the ALL was based on the anterior-posterior and proximal-distal distances from the attachment of the lateral collateral ligament (LCL). The tibial attachment point was based on the distance from the Gerdy tubercle to the fibular head and the distance from the lateral tibial plateau. The ligaments from the first 10 dissections were sent for histological analysis. The ALL was found in all 20 knees. The femoral attachment of the ALL at the lateral epicondyle averaged 3.5 mm distal and 2.2 mm anterior to the attachment of the LCL. Two distal attachments were observed: one inserts into the lateral meniscus, the other between the Gerdy tubercle and the fibular head, approximately 4.4 mm distal to the tibial articular cartilage. The mean measurements for the ligament were 37.3 mm (length), 7.4 mm (width), and 2.7 mm (thickness). The histological analysis of the ligaments revealed dense connective tissue. The ALL is consistently present in the anterolateral region of the knee. Its attachment to the femur is anterior and distal to the attachment of the LCL. Moving distally, it bifurcates at close to half of its length. The ALL features 2 distal attachments, one at the lateral meniscus and the other between the Gerdy tubercle and the fibular head. The ALL may be important in maintaining normal rotatory limits of knee motion; ALL rupture could be responsible for rotatory laxity after isolated intra-articular reconstruction of the ACL.
Feigenbaum, Luis A; Baraga, Michael; Kaplan, Lee D; Roach, Kathryn E; Calpino, Kathryn M; Dorsey, Katie; Martorelli, Cristina; Sagarduy, Beatriz; King, Lesley-Anne; Scavo, Vincent A
2015-02-01
Much attention has been solely paid to physical outcome measures for return to sport after injury in the past. However, current research shows that the psychological component of these injuries can be more predictive of return to sport than physical outcome measures. The purpose of this case report is to describe the successful return to sport following surgery of a complicated tibia and fibula fracture of a Division I collegiate women's soccer player with a low level of kinesiophobia. A 22-year-old female sustained a closed traumatic mid-shaft fracture of her tibia and fibula. During a high velocity play she sustained a direct blow while colliding with an opposing player's cleats. As a result of the play, her distal tibia was displaced 908 to the rest of her leg. She underwent a closed reduction and tibial internal fixation with an intramedullary rod. Outcome scores were tracked using the IKDC and TSK-11. The IKDC measures symptoms, function, and sport activity related to knee injuries. The TSK-11 measures fear of movement and re-injury, which was important to assess during this case due to the gruesome nature of the injury. At 4 months, the subject became symptomatic over the fibula and was diagnosed with a fibular nonunion fracture. This was unexpected due to the low incidence of and usual asymptomatic nature of fibular nonunion fractures, which required an additional surgery. TSK-11 scores ranged from 19-20 throughout, signifying low levels of kinesiophobia. IKDC scores improved from 8.05 to 60.92. The subject ultimately signed a professional soccer contract. The rehabilitation of this subject was complex due to her low levels of kinesiophobia, self-guided overtraining, and the potential role they may have had in her fibular nonunion fracture. This case study demonstrates a successful outcome despite a unique injury presentation, multiple surgeries, and low levels of kinesiophobia. While a low level of kinesiophobia can be detrimental to rehabilitation compliance, it may have benefited her in the long-term. 5.
Prospective study of the " Inside-Out" arthroscopic ankle ligament technique: Preliminary result.
Nery, Caio; Fonseca, Lucas; Raduan, Fernando; Moreno, Marcus; Baumfeld, Daniel
2017-03-22
Lateral ankle ligament injury is among the most common orthopedic injuries. The objective of this study is to present the preliminary prospective results of treatment using the "Inside-Out" variant of the fully arthroscopic Broström-Gould technique. Twenty six patients were included: 20 male and 6 female, aged 19-60 years, mean 41 years. All patients had positive "anterior drawer" and "talar tilt" tests. When necessary, cartilage injuries were treated with microfracture and arthroscopic resection for anterior impingement; three patients had hindfoot varus, on whom Dwyer osteotomy was performed; one patient had peroneal tendinopathy and was treated with tendoscopic debridement and another one had partial injury of the deltoid ligament, which was treated by direct repair. Two arthroscopic surgery portals were used; the anteromedial and anterolateral. After careful inspection of the joint, the anterior surface of the fibula was cleaned to resect the remains of the anterior talo-fibular ligament. An anchor with two sutures was placed on the anterior aspect of the fibula, 1cm from the distal apex of the malleolus. The sutures were passed through the remnant of the anterior talo-fibular ligament as well as the extensor retinaculum using special curved needles. Duncan knots were used to tie the ligament and the inferior extensor retinaculum while the ankle was kept in a neutral position. Patients were kept immobilized non-weight bearing for 2 weeks and were then allowed to start weight bearing in a removable protective boot for 4 weeks. The patients were able to return to sporting activities 6 months after surgery. After a mean follow-up of 27 months (range 21-36 months), patients were functionally evaluated using the American Orthopedics Foot and Ankle Society (AOFAS) ankle score. The mean preoperative value was 58 points, while the mean postoperative value increased to 90 points. One patient had paresthesia in the superficial fibular nerve area, which resolved spontaneously. Despite the limited cohort and the relatively short follow-up period, the use of the "inside-out" arthroscopic technique may be considered as a valid option for the treatment of chronic ankle instability. Copyright © 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
Ipsilateral intact fibula as a predictor of tibial plafond fracture pattern and severity.
Luk, Pamela C; Charlton, Timothy P; Lee, Jackson; Thordarson, David B
2013-10-01
The objective of this study was to determine whether there is a difference in fracture pattern and severity of comminution between tibial plafond fractures with and without associated fibular fractures using computed tomography (CT). We hypothesized that the presence of an intact fibula was predictive of increased tibial plafond fracture severity. This was a case control, radiographic review performed at a single level I university trauma center. Between November 2007 and July 2011, 104 patients with 107 operatively treated tibial pilon fractures and preoperative CT scans were identified: 70 patients with 71 tibial plafond fractures had associated fibular fractures, and 34 patients with 36 tibial plafond fractures had intact fibulas. Four criteria were compared between the 2 groups: AO/OTA classification of distal tibia fractures, Topliss coronal and sagittal fracture pattern classification, plafond region of greatest comminution, and degree of proximal extension of fracture line. The intact fibula group had greater percentages of AO/OTA classification B2 type (5.5 vs 0, P = .046) and B3 type (52.8 vs 28.2, P = .013). Conversely, the percentage of AO/OTA classification C3 type was greater in the fractured fibula group (53.5 vs 30.6, P = .025). Evaluation using the Topliss sagittal and coronal classifications revealed no difference between the 2 groups (P = .226). Central and lateral regions of the plafond were the most common areas of comminution in fractured fibula pilons (32% and 31%, respectively). The lateral region of the plafond was the most common area of comminution in intact fibula pilon fractures (42%). There was no statistically significant difference (P = .71) in degree of proximal extension of fracture line between the 2 groups. Tibial plafond fractures with intact fibulas were more commonly associated with AO/OTA classification B-type patterns, whereas those with fractured fibulas were more commonly associated with C-type patterns. An intact fibula may be predictive of less comminution of the plafond. The lateral and central regions of the plafond were the most common areas of comminution in tibial plafond fractures, regardless of fibular status. Level III, case control study.
Raghupathy, Rakesh K; Zhang, Xun; Alhasani, Reem H; Zhou, Xinzhi; Mullin, Margaret; Reilly, James; Li, Wenchang; Liu, Mugen; Shu, Xinhua
2016-08-01
Photoreceptors are highly specialized sensory neurons that possess a modified primary cilium called the outer segment. Photoreceptor outer segment formation and maintenance require highly active protein transport via a process known as intraflagellar transport. Anterograde transport in outer segments is powered by the heterotrimeric kinesin II and coordinated by intraflagellar transport proteins. Here, we describe a new zebrafish model carrying a nonsense mutation in the kinesin II family member 3A (kif3a) gene. Kif3a mutant zebrafish exhibited curved body axes and kidney cysts. Outer segments were not formed in most parts of the mutant retina, and rhodopsin was mislocalized, suggesting KIF3A has a role in rhodopsin trafficking. Both rod and cone photoreceptors degenerated rapidly between 4 and 9 days post fertilization, and electroretinography response was not detected in 7 days post fertilization mutant larvae. Loss of KIF3A in zebrafish also resulted in an intracellular transport defect affecting anterograde but not retrograde transport of organelles. Our results indicate KIF3A plays a conserved role in photoreceptor outer segment formation and intracellular transport. Copyright © 2016 John Wiley & Sons, Ltd.
Small bowel obstruction caused by congenital transmesenteric defect.
Nouira, F; Dhaou, Ben M; Charieg, A; Ghorbel, S; Jlidi, S; Chaouachi, B
2011-01-01
Transmesenteric hernias are extremely rare. A strangulated hernia through a mesenteric opening is a rare operative finding. Preoperative diagnosis still is difficult in spite of the imaging techniques currently available. The authors describe two cases of paediatric patients presenting with bowel obstruction resulting from a congenital mesenteric hernia. The first patient had a 3-cm wide congenital defect in the ileal mesentery through which the sigmoid colon had herniated. The second patient is a newborn infant who presented with symptoms and radiographic evidence of neonatal occlusion. At surgical exploration, a long segment of the small bowel had herniated in a defect in the ileal mesentery. A brief review of epidemiology and anatomy of transmesenteric hernias is included, along with a discussion of the difficulties in diagnosis and treatment of this condition.
2015-12-01
found with Tukey’s HSD post hoc analysis. Several target genes such as Oct4, Sox2, TGFB, and Col1A1 were generally up-regulated in all sections. In...expression analysis from the Aim 1 samples presented several upregulated target genes such as Oct4, Sox2, TGFB, and Col1A1 in all sections. No...TGFB, and Col1A1 . • Data from cellular analysis, histology, gene expression analysis and microCT are being assembled for the predictive model
Sahly, Iman; Dufour, Eric; Schietroma, Cataldo; Michel, Vincent; Bahloul, Amel; Perfettini, Isabelle; Pepermans, Elise; Estivalet, Amrit; Carette, Diane; Aghaie, Asadollah; Ebermann, Inga; Lelli, Andrea; Iribarne, Maria; Hardelin, Jean-Pierre; Weil, Dominique; Sahel, José-Alain; El-Amraoui, Aziz; Petit, Christine
2012-10-15
The mechanisms underlying retinal dystrophy in Usher syndrome type I (USH1) remain unknown because mutant mice lacking any of the USH1 proteins-myosin VIIa, harmonin, cadherin-23, protocadherin-15, sans-do not display retinal degeneration. We found here that, in macaque photoreceptor cells, all USH1 proteins colocalized at membrane interfaces (i) between the inner and outer segments in rods and (ii) between the microvillus-like calyceal processes and the outer segment basolateral region in rods and cones. This pattern, conserved in humans and frogs, was mediated by the formation of an USH1 protein network, which was associated with the calyceal processes from the early embryonic stages of outer segment growth onwards. By contrast, mouse photoreceptors lacked calyceal processes and had no USH1 proteins at the inner-outer segment interface. We suggest that USH1 proteins form an adhesion belt around the basolateral region of the photoreceptor outer segment in humans, and that defects in this structure cause the retinal degeneration in USH1 patients.
Localization of Usher 1 proteins to the photoreceptor calyceal processes, which are absent from mice
Sahly, Iman; Dufour, Eric; Schietroma, Cataldo; Michel, Vincent; Bahloul, Amel; Perfettini, Isabelle; Pepermans, Elise; Estivalet, Amrit; Carette, Diane; Aghaie, Asadollah; Ebermann, Inga; Lelli, Andrea; Iribarne, Maria; Hardelin, Jean-Pierre; Weil, Dominique; Sahel, José-Alain
2012-01-01
The mechanisms underlying retinal dystrophy in Usher syndrome type I (USH1) remain unknown because mutant mice lacking any of the USH1 proteins—myosin VIIa, harmonin, cadherin-23, protocadherin-15, sans—do not display retinal degeneration. We found here that, in macaque photoreceptor cells, all USH1 proteins colocalized at membrane interfaces (i) between the inner and outer segments in rods and (ii) between the microvillus-like calyceal processes and the outer segment basolateral region in rods and cones. This pattern, conserved in humans and frogs, was mediated by the formation of an USH1 protein network, which was associated with the calyceal processes from the early embryonic stages of outer segment growth onwards. By contrast, mouse photoreceptors lacked calyceal processes and had no USH1 proteins at the inner–outer segment interface. We suggest that USH1 proteins form an adhesion belt around the basolateral region of the photoreceptor outer segment in humans, and that defects in this structure cause the retinal degeneration in USH1 patients. PMID:23045546
Wu, Mingxuan; Zhang, Yanning; Liu, Huijuan; Dong, Fusheng
2018-01-01
Background The ideal healing technique for periodontal tissue defects would involve the functional regeneration of the alveolar bone, cementum, and periodontal ligament, with new periodontal attachment formation. In this study, gingival fibroblasts were induced and a “sandwich” tissue-engineered complex (a tissue-engineered periodontal membrane between 2 tissue-engineered mineralized membranes) was constructed to repair periodontal defects. We evaluated the effects of gingival fibroblasts used as seed cells on the repair of periodontal defects and periodontal regeneration. Material/Methods Primitively cultured gingival fibroblasts were seeded bilaterally on Bio-Gide collagen membrane (a tissue-engineered periodontal membrane) or unilaterally on small intestinal submucosa segments, and their mineralization was induced. A tissue-engineered sandwich was constructed, comprising the tissue-engineered periodontal membrane flanked by 2 mineralized membranes. Periodontal defects in premolar regions of Beagles were repaired using the tissue-engineered sandwich or periodontal membranes. Periodontal reconstruction was compared to normal and trauma controls 10 or 20 days postoperatively. Results Periodontal defects were completely repaired by the sandwich tissue-engineered complex, with intact new alveolar bone and cementum, and a new periodontal ligament, 10 days postoperatively. Conclusions The sandwich tissue-engineered complex can achieve ideal periodontal reconstruction rapidly. PMID:29470454
Navarro, Pedro J; Fernández-Isla, Carlos; Alcover, Pedro María; Suardíaz, Juan
2016-07-27
This paper presents a robust method for defect detection in textures, entropy-based automatic selection of the wavelet decomposition level (EADL), based on a wavelet reconstruction scheme, for detecting defects in a wide variety of structural and statistical textures. Two main features are presented. One of the new features is an original use of the normalized absolute function value (NABS) calculated from the wavelet coefficients derived at various different decomposition levels in order to identify textures where the defect can be isolated by eliminating the texture pattern in the first decomposition level. The second is the use of Shannon's entropy, calculated over detail subimages, for automatic selection of the band for image reconstruction, which, unlike other techniques, such as those based on the co-occurrence matrix or on energy calculation, provides a lower decomposition level, thus avoiding excessive degradation of the image, allowing a more accurate defect segmentation. A metric analysis of the results of the proposed method with nine different thresholding algorithms determined that selecting the appropriate thresholding method is important to achieve optimum performance in defect detection. As a consequence, several different thresholding algorithms depending on the type of texture are proposed.
Kumar, Sanjay; Ponnazhagan, Selvarangan
2012-04-01
Although the number of mesenchymal stem cells (MSC) in the bone marrow is sufficient to maintain skeletal homeostasis, in osteopenic pathology, aggravated osteoclast activity or insufficient osteoblast numbers ensue, affecting normal bone remodeling. Most of the currently available therapies are anti-resorptive with limited osteogenic potential. Since mobilization of stem/progenitors from the BM is a prerequisite for their participation in tissue repair, amplification of endogenous stem cells may provide an alternative approach in these conditions. The present study determined the potential of MSC mobilization in vivo, using combinations of different growth factors with the CXCR4 antagonist, AMD3100, in a mouse model of segmental bone defect. Results indicated that among several factors tested IGF1 had maximum proliferative ability of MSC in vitro. Results of the in vivo studies indicated that the combination of IGF1 and AMD3100 provided significant augmentation of bone growth as determined by DXA, micro-CT and histomorphometry in mice bearing segmental fractures. Further, characterization of MSC isolated from mice treated with IGF1 and AMD3100 indicated Akt/PI3K, MEK1/2-Erk1/2 and smad2/3 as key signaling pathways mediating this effect. These data indicate the potential of in vivo stem cell mobilization as a novel alternative for bone healing. Copyright © 2012 Elsevier Inc. All rights reserved.
Fu, Xin; Yuan, Jun
2017-07-24
Coherent x-ray diffraction investigations on Ag five-fold twinned nanowires (FTNWs) have drawn controversial conclusions concerning whether the intrinsic 7.35° angular gap could be compensated homogeneously through phase transformation or inhomogeneously by forming disclination strain field. In those studies, the x-ray techniques only provided an ensemble average of the structural information from all the Ag nanowires. Here, using three-dimensional (3D) electron diffraction mapping approach, we non-destructively explore the cross-sectional strain and the related strain-relief defect structures of an individual Ag FTNW with diameter about 30 nm. The quantitative analysis of the fine structure of intensity distribution combining with kinematic electron diffraction simulation confirms that for such a Ag FTNW, the intrinsic 7.35° angular deficiency results in an inhomogeneous strain field within each single crystalline segment consistent with the disclination model of stress-relief. Moreover, the five crystalline segments are found to be strained differently. Modeling analysis in combination with system energy calculation further indicates that the elastic strain energy within some crystalline segments, could be partially relieved by the creation of stacking fault layers near the twin boundaries. Our study demonstrates that 3D electron diffraction mapping is a powerful tool for the cross-sectional strain analysis of complex 1D nanostructures.
Quantitative assessment in thermal image segmentation for artistic objects
NASA Astrophysics Data System (ADS)
Yousefi, Bardia; Sfarra, Stefano; Maldague, Xavier P. V.
2017-07-01
The application of the thermal and infrared technology in different areas of research is considerably increasing. These applications involve Non-destructive Testing (NDT), Medical analysis (Computer Aid Diagnosis/Detection- CAD), Arts and Archaeology among many others. In the arts and archaeology field, infrared technology provides significant contributions in term of finding defects of possible impaired regions. This has been done through a wide range of different thermographic experiments and infrared methods. The proposed approach here focuses on application of some known factor analysis methods such as standard Non-Negative Matrix Factorization (NMF) optimized by gradient-descent-based multiplicative rules (SNMF1) and standard NMF optimized by Non-negative least squares (NNLS) active-set algorithm (SNMF2) and eigen decomposition approaches such as Principal Component Thermography (PCT), Candid Covariance-Free Incremental Principal Component Thermography (CCIPCT) to obtain the thermal features. On one hand, these methods are usually applied as preprocessing before clustering for the purpose of segmentation of possible defects. On the other hand, a wavelet based data fusion combines the data of each method with PCT to increase the accuracy of the algorithm. The quantitative assessment of these approaches indicates considerable segmentation along with the reasonable computational complexity. It shows the promising performance and demonstrated a confirmation for the outlined properties. In particular, a polychromatic wooden statue and a fresco were analyzed using the above mentioned methods and interesting results were obtained.
Implementation of a General Real-Time Visual Anomaly Detection System Via Soft Computing
NASA Technical Reports Server (NTRS)
Dominguez, Jesus A.; Klinko, Steve; Ferrell, Bob; Steinrock, Todd (Technical Monitor)
2001-01-01
The intelligent visual system detects anomalies or defects in real time under normal lighting operating conditions. The application is basically a learning machine that integrates fuzzy logic (FL), artificial neural network (ANN), and generic algorithm (GA) schemes to process the image, run the learning process, and finally detect the anomalies or defects. The system acquires the image, performs segmentation to separate the object being tested from the background, preprocesses the image using fuzzy reasoning, performs the final segmentation using fuzzy reasoning techniques to retrieve regions with potential anomalies or defects, and finally retrieves them using a learning model built via ANN and GA techniques. FL provides a powerful framework for knowledge representation and overcomes uncertainty and vagueness typically found in image analysis. ANN provides learning capabilities, and GA leads to robust learning results. An application prototype currently runs on a regular PC under Windows NT, and preliminary work has been performed to build an embedded version with multiple image processors. The application prototype is being tested at the Kennedy Space Center (KSC), Florida, to visually detect anomalies along slide basket cables utilized by the astronauts to evacuate the NASA Shuttle launch pad in an emergency. The potential applications of this anomaly detection system in an open environment are quite wide. Another current, potentially viable application at NASA is in detecting anomalies of the NASA Space Shuttle Orbiter's radiator panels.
Castada, Hardy Z; Wick, Cheryl; Taylor, Kaitlyn; Harper, W James
2014-04-01
Splits/cracks are recurring product defects that negatively affect the Swiss cheese industry. Investigations to understand the biophysicochemical aspects of these defects, and thus determine preventive measures against their occurrence, are underway. In this study, selected-ion, flow tube mass spectrometry was employed to determine the volatile organic compound (VOC) profiles present in the headspace of split compared with nonsplit cheeses. Two sampling methodologies were employed: split compared with nonsplit cheese vat pair blocks; and comparison of blind, eye, and split segments within cheese blocks. The variability in VOC profiles was examined to evaluate the potential biochemical pathway chemistry differences within and between cheese samples. VOC profile inhomogeneity was most evident in cheeses between factories. Evaluation of biochemical pathways leading to the formation of key VOCs differentiating the split from the blind and eye segments within factories indicated release of additional carbon dioxide by-product. These results suggest a factory-dependent cause of split formation that could develop from varied fermentation pathways in the blind, eye, and split areas within a cheese block. The variability of VOC profiles within and between factories exhibit varied biochemical fermentation pathways that could conceivably be traced back in the making process to identify parameters responsible for split defect. © 2014 Institute of Food Technologists®
Sternberg, Leonard; Wald, Robert W.; Feiglin, David H.I.; Morch, John E.
1978-01-01
Myocardial perfusion imaging with thallium-201 and electrocardiography with the subject at rest and undergoing submaximal treadmill exercise were performed in 19 men and 3 women. Selective coronary arteriography and left ventriculography showed that 7 had normal coronary arteries and 15 had coronary artery disease. The 11 persons with electrocardiographic evidence of an old myocardial infarct (q waves) had a perfusion defect at rest in the area of the infarct and a segmental abnormality of wall motion apparent on the left ventriculogram corresponding to the perfusion defect. Myocardial perfusion imaging and electrocardiography were equally sensitive in detecting coronary artery disease in exercising individuals: perfusion defects were noted in 7 of the 15 persons with coronary artery disease, and diagnostic ST-segment depression was present in 8 of the 15. Combination of the results of the two tests with exercise permitted the identification of 11 of the 15 persons and improved the sensitivity. Combination of the results of rest and exercise imaging and electrocardiography permitted the identification of 94% of the patients with coronary artery disease. Myocardial perfusion imaging with 201TI in the subject at rest is a sensitive indicator of previous myocardial infarction. Imaging after the subject has exercised is a useful adjunct to conventional exercise electrocardiography, especially in those whose exercise electrocardiogram is non-interpretable. ImagesFIG. 1FIG. 2FIG. 3FIG. 4FIG. 5 PMID:630487
NASA Astrophysics Data System (ADS)
Li, Guoyuan; Wang, Lei; Pan, Wei; Yang, Fei; Jiang, Wenbo; Wu, Xianbo; Kong, Xiangdong; Dai, Kerong; Hao, Yongqiang
2016-09-01
Metallic implants with a low effective modulus can provide early load-bearing and reduce stress shielding, which is favorable for increasing in vivo life-span. In this research, porous Ti6Al4V scaffolds with three pore sizes (300~400, 400~500, and 500~700 μm) were manufactured by Electron Beam Melting, with an elastic modulus range of 3.7 to 1.7 GPa. Cytocompatibility in vitro and osseointegration ability in vivo of scaffolds were assessed. hBMSCs numbers increased on all porous scaffolds over time. The group with intended pore sizes of 300 to 400 μm was significantly higher than that of the other two porous scaffolds at days 5 and 7. This group also had higher ALP activity at day 7 in osteogenic differentiation experiment. The scaffold with pore size of 300 to 400 μm was implanted into a 30-mm segmental defect of goat metatarsus. In vivo evaluations indicated that the depth of bone ingrowth increased over time and no implant dislocation occurred during the experiment. Based on its better cytocompatibility and favorable bone ingrowth, the present data showed the capability of the additive manufactured porous Ti6Al4V scaffold with an intended pore size of 300 to 400 μm for large segmental bone defects.
Non union of an epiphyseal fibular fracture in a pediatric patient.
Mirmiran, Roya; Schuberth, John M
2006-01-01
There are few reports on delayed or nonunion in the pediatric ankle fracture. The authors present a case of a nonunion of a mid-epiphyseal fracture of the distal fibula, described as a type 7 pediatric fracture. Both the occurrence of this injury pattern and a nonunion has not been reported in the same patient. Operative reduction of the nonunion resulted in a satisfactory outcome.
Incidence and variance of foot and ankle injuries in elite college football players.
Kaplan, Lee D; Jost, Patrick W; Honkamp, Nicholas; Norwig, John; West, Robin; Bradley, James P
2011-01-01
We conducted a study on the risk for foot and ankle injuries in college football players on the basis of injury type and player position. In February 2006, we evaluated 320 intercollegiate football players at the National Football League Combine. All pathologic conditions and surgical procedures of the foot and ankle were recorded, and data were analyzed by player position to detect any trends. Seventy-two percent (n = 231) of the players had a history of foot and ankle injuries, with a total of 287 foot and ankle injuries (1.24 injuries/player injured). The most common injuries were lateral ankle sprain (n = 115), syndesmotic sprain (50), metatarsophalangeal dislocation/turf toe (36), and fibular fracture (25). Foot and ankle injuries were most common in kickers/punters (100% incidence), special teams (100%), running backs (83%), wide receivers (83%), and offensive linemen (80%). Lateral ankle sprains, the most common injuries, were treated surgically only 2.6% of the time. Offensive linemen were most likely to have had syndesmotic sprains (32%), and quarterbacks had the highest incidence of fibular fractures (16%). Foot and ankle injuries are common in collegiate football players, affecting 72% of players. Thirteen percent underwent surgical treatment. Trends are seen in the types of injuries for the different player positions.
Mizuno, Ju; Namba, Chikara; Takahashi, Toru
2014-10-01
We investigated external pressure on peroneal nerve tract coming in contact with two kinds of leg holders using pressure distribution measurement system BIG- MAT® (Nitta Corp., Osaka) in the lithotomy position Peak contact (active) pressure at the left fibular head region coming in contact with knee-crutch-type leg holder M® (Takara Belmont Corp., Osaka), which supports the left popliteal fossa, was 78.0 ± 26.4 mmHg. On the other hand, peak contact pressure at the left lateral lower leg region coming in contact with boot-support-type leg holder Bel Flex® (Takara Belmont Corp., Osaka), which supports the left lower leg and foot was 26.3±7.9 mmHg. These results suggest that use of knee-crutch-type leg holder is more likely to induce common peroneal nerve palsy at the fibular head region, but use of boot-support-type leg holder dose not easily induce superficial peroneal nerve palsy at the lateral lower leg region, because capillary blood pressure is known to be 32 mmHg. Safer holders for positioning will be developed to prevent nerve palsy based on the analysis of chronological change in external pressure using BIG-MAT® system during anesthesia.
Macedo, Christiane de Souza Guerino; Vicente, Rafael Chagas; Cesário, Mauricio Donini; Guirro, Rinaldo Roberto de Jesus
2016-01-01
The purpose of this study was to evaluate the effects of cold-water immersion on the electromyographic (EMG) response of the lower limb and balance during unipodal jump landing. The evaluation comprised 40 individuals (20 basketball players and 20 non-athletes). The EMG response in the lateral gastrocnemius, tibialis anterior, fibular longus, rectus femoris, hamstring and gluteus medius; amplitude and mean speed of the centre of pressure, flight time and ground reaction force (GRF) were analysed. All volunteers remained for 20 min with their ankle immersed in cold-water, and were re-evaluated immediately post and after 10, 20 and 30 min of reheating. The Shapiro-Wilk test, Friedman test and Dunn's post test (P < 0.05) were used. The EMG response values decreased for the lateral gastrocnemius, tibialis anterior, fibular longus and rectus femoris of both athletes and non-athletes (P < 0.05). The comparison between the groups showed that the EMG response was lower for the athletes. Lower jump flight time and GRF, greater amplitude and mean speed of centre of pressure were predominant in the athletes. Cold-water immersion decreased the EMG activity of the lower limb, flight time and GRF and increased the amplitude and mean speed of centre of pressure.
Resection arthrodesis for giant cell tumors around the knee.
Kapoor, Sudhir K; Tiwari, Akshay
2007-04-01
Giant cell tumors (GCTs) of bone are aggressive benign tumors. Wide resection is reserved for a small subset of patients with biologically more aggressive, recurrent and extensive tumors. As the patients affected with GCT are young or middle-aged adults with a normal life expectancy, arthrodesis is an attractive option for reconstruction in these patients. Thirty-six patients of mean age 33.1 years with Campanacci Grade III giant cell tumors around the knee (20 distal femoral and 16 proximal tibial) were treated with wide resection and arthrodesis from January 1996 through January 2006. Arthrodesis was performed using plating with free fibular graft (n = 18), IM nail with free fibular graft (n = 8) and IM nail combined with ring fixator using bone transport (n = 10). Fusion after the first surgery was achieved in 77.7%, 75% and 90% of the patients in the three groups respectively. Local recurrence was seen in two patients and repeat surgery for nonunion/ graft fracture had to be done in four patients and two patients in the plating and nailing groups respectively. Wide resection and arthrodesis in aggressive GCTs around the knee is a good treatment option. IM nail combined with a ring fixator seems to be a good method of arthrodesis with high fusion rates, least shortening and early rehabilitation.
Villafañe, Jorge Hugo; Pillastrini, Paolo; Borboni, Alberto
2013-09-01
The purpose of this case report is to describe a therapeutic intervention for peroneal nerve paralysis involving the sciatic nerve. A 24-year-old man presented with peroneal nerve paralysis with decreased sensation, severe pain in the popliteal fossa, and steppage gait, which occurred 3 days prior to the consultation. Magnetic resonance imaging and electromyography confirmed lumbar disk herniation with sciatic common peroneal nerve entrapment in the popliteal fossa. A combined treatment protocol of spinal and fibular head manipulation and neurodynamic mobilization including soft tissue work of the psoas and hamstring muscles was performed. Outcome measures were assessed at pretreatment, 1 week posttreatment, and 3-month follow-up and included numeric pain rating scale, range of motion, pressure pain threshold, and manual muscle testing. Treatment interventions were applied for 3 sessions over a period of 1 week. Results showed reduction of the patient's subjective pain and considerable improvement in range of motion, strength, and sensation in his left foot, which was restored to full function. A combined program of spinal and fibular head manipulation and neurodynamic mobilization reduced pain, increased range of motion and strength, and restored full function to the left leg in this patient who had severe functional impairment related to a compressed left common peroneal nerve.
Rogers, Ian S.; Cury, Ricardo C.; Blankstein, Ron; Shapiro, Michael D.; Nieman, Koen; Hoffmann, Udo; Brady, Thomas J.; Abbara, Suhny
2010-01-01
Background Despite rapid advances in cardiac computed tomography (CT), a strategy for optimal visualization of perfusion abnormalities on CT has yet to be validated. Objective To evaluate the performance of several post-processing techniques of source data sets to detect and characterize perfusion defects in acute myocardial infarctions with cardiac CT. Methods Twenty-one subjects (18 men; 60 ± 13 years) that were successfully treated with percutaneous coronary intervention for ST-segment myocardial infarction underwent 64-slice cardiac CT and 1.5 Tesla cardiac MRI scans following revascularization. Delayed enhancement MRI images were analyzed to identify the location of infarcted myocardium. Contiguous short axis images of the left ventricular myocardium were created from the CT source images using 0.75mm multiplanar reconstruction (MPR), 5mm MPR, 5mm maximal intensity projection (MIP), and 5mm minimum intensity projection (MinIP) techniques. Segments already confirmed to contain infarction by MRI were then evaluated qualitatively and quantitatively with CT. Results Overall, 143 myocardial segments were analyzed. On qualitative analysis, the MinIP and thick MPR techniques had greater visibility and definition than the thin MPR and MIP techniques (p < 0.001). On quantitative analysis, the absolute difference in Hounsfield Unit (HU) attenuation between normal and infarcted segments was significantly greater for the MinIP (65.4 HU) and thin MPR (61.2 HU) techniques. However, the relative difference in HU attenuation was significantly greatest for the MinIP technique alone (95%, p < 0.001). Contrast to noise was greatest for the MinIP (4.2) and thick MPR (4.1) techniques (p < 0.001). Conclusion The results of our current investigation found that MinIP and thick MPR detected infarcted myocardium with greater visibility and definition than MIP and thin MPR. PMID:20579617
Magnetic resonance imaging study of eye congenital birth defects in mouse model
Tucker, Zachary; Mongan, Maureen; Meng, Qinghang; Xia, Ying
2017-01-01
Purpose Embryonic eyelid closure is a well-documented morphogenetic episode in mammalian eye development. Detection of eyelid closure defect in humans is a major challenge because eyelid closure and reopen occur entirely in utero. As a consequence, congenital eye defects that are associated with failure of embryonic eyelid closure remain unknown. To fill the gap, we developed a mouse model of defective eyelid closure. This preliminary work demonstrates that the magnetic resonance imaging (MRI) approach can be used for the detection of extraocular muscle abnormalities in the mouse model. Methods Mice with either normal (Map3k1+/−) or defective (Map3k1−/−) embryonic eyelid closure were used in this study. Images of the extraocular muscles were obtained with a 9.4 T high resolution microimaging MRI system. The extraocular muscles were identified, segmented, and measured in each imaging slice using an in-house program. Results In agreement with histological findings, the imaging data show that mice with defective embryonic eyelid closure develop less extraocular muscle than normal mice. In addition, the size of the eyeballs was noticeably reduced in mice with defective embryonic eyelid closure. Conclusions We demonstrated that MRI can potentially be used for the study of extraocular muscle in the mouse model of the eye open-at-birth defect, despite the lack of specificity of muscle group provided by the current imaging resolution. PMID:28848319
Finite element investigation of the effect of a bifid arch on loading of the vertebral isthmus.
Quah, Conal; Yeoman, Mark S; Cizinauskas, Andrius; Cooper, Kevin C; Peirce, Nick S; McNally, Donal S; Boszczyk, Bronek M
2014-04-01
The biomechanical effect of a bifid arch as seen in spina bifida occulta and following a midline laminectomy is poorly understood. To test the hypothesis that fatigue failure limits will be exceeded in the case of a bifid arch, but not in the intact case, when the segment is subjected to complex loading corresponding to normal sporting activities. Finite element analysis. Finite element model of an intact L4-S1 human lumbar motion segment including ligaments was used. A section of the L5 vertebral arch and spinous process was removed to create the model with a midline defect. The models were loaded axially to 1 kN and then combined with axial rotation of 3°. Bilateral stresses, alternating stresses, and shear fatigue failure on both models were assessed and compared. Under 1 kN axial load, the von Mises stresses observed in midline defect case and in the intact case were very similar (differences <5 MPa) having a maximum at the ventral end of the isthmus that decreases monotonically to the dorsal end. However, under 1 kN axial load and rotation, the maximum von Mises stresses observed in the ipsilateral L5 isthmus in the midline defect case (31 MPa) was much higher than the intact case (24.2 MPa), indicating a lack of load sharing across the vertebral arch in the midline defect case. When assessing the equivalent alternating shear stress amplitude, this was found to be 22.6 MPa for the midline defect case and 13.6 MPa for the intact case. From this, it is estimated that shear fatigue failure will occur in less than 70,000 cycles, under repetitive axial load and rotation conditions in the midline defect case, whereas for the intact case, fatigue failure will occur only after more than 10 million cycles. A bifid arch predisposes the isthmus to early fatigue fracture by generating increased stresses across the inferior isthmus of the inferior articular process, specifically in combined axial rotation and anteroposterior shear. Copyright © 2014 Elsevier Inc. All rights reserved.
Arrighi, James A; Burg, Matthew; Cohen, Ira S; Soufer, Robert
2003-01-01
Mental stress (MS) is an important provocateur of myocardial ischemia in many patients with chronic coronary artery disease. The majority of laboratory assessments of ischemia in response to MS have included measurements of either myocardial perfusion or function alone. We performed this study to determine the relationship between alterations in perfusion and ventricular function during MS. Methods and results Twenty-eight patients with reversible perfusion defects on exercise or pharmacologic stress myocardial perfusion imaging (MPI) underwent simultaneous technetium 99m sestamibi single photon emission computed tomography (SPECT) MPI and transthoracic echocardiography at rest and during MS according to a mental arithmetic protocol. In all cases the MS study was performed within 4 weeks of the initial exercise or pharmacologic MPI that demonstrated ischemia. SPECT studies were analyzed visually with the use of a 13-segment model and quantitatively by semiautomated circumferential profile analysis. Echocardiograms were graded on a segmental model for regional wall motion on a 4-point scale. Of 28 patients, 18 (64%) had perfusion defects and/or left ventricular dysfunction develop during MS: 9 (32%) had myocardial perfusion defects develop, 6 (21%) had regional or global left ventricular dysfunction develop, and 3 (11%) had both perfusion defects and left ventricular dysfunction develop. The overall concordance between perfusion and function criteria for ischemia during MS was only 46%. Among 9 patients with MS-induced left ventricular dysfunction, 5 had new regional wall motion abnormalities and 4 had a global decrement in function. In patients with MS-induced ischemia by SPECT, the number of reversible perfusion defects was similar during both MS and exercise/pharmacologic stress (2.8 +/- 2.0 vs 3.5 +/- 1.8, P =.41). Hemodynamic changes during MS were similar whether patients were divided on the basis of perfusion defects or left ventricular dysfunction during MS. These data indicate the feasibility of simultaneous assessment of perfusion and function responses during MS. Flow and function responses to MS are frequently not concordant. These data suggest that MS-induced changes in perfusion may represent a different phenomenon than MS-induced changes in left ventricular function (either globally or regionally).
Sun, Shuping; Jiang, Zhongwei; Wang, Haibin; Fang, Yu
2014-05-01
This paper proposes a novel automatic method for the moment segmentation and peak detection analysis of heart sound (HS) pattern, with special attention to the characteristics of the envelopes of HS and considering the properties of the Hilbert transform (HT). The moment segmentation and peak location are accomplished in two steps. First, by applying the Viola integral waveform method in the time domain, the envelope (E(T)) of the HS signal is obtained with an emphasis on the first heart sound (S1) and the second heart sound (S2). Then, based on the characteristics of the E(T) and the properties of the HT of the convex and concave functions, a novel method, the short-time modified Hilbert transform (STMHT), is proposed to automatically locate the moment segmentation and peak points for the HS by the zero crossing points of the STMHT. A fast algorithm for calculating the STMHT of E(T) can be expressed by multiplying the E(T) by an equivalent window (W(E)). According to the range of heart beats and based on the numerical experiments and the important parameters of the STMHT, a moving window width of N=1s is validated for locating the moment segmentation and peak points for HS. The proposed moment segmentation and peak location procedure method is validated by sounds from Michigan HS database and sounds from clinical heart diseases, such as a ventricular septal defect (VSD), an aortic septal defect (ASD), Tetralogy of Fallot (TOF), rheumatic heart disease (RHD), and so on. As a result, for the sounds where S2 can be separated from S1, the average accuracies achieved for the peak of S1 (AP₁), the peak of S2 (AP₂), the moment segmentation points from S1 to S2 (AT₁₂) and the cardiac cycle (ACC) are 98.53%, 98.31% and 98.36% and 97.37%, respectively. For the sounds where S1 cannot be separated from S2, the average accuracies achieved for the peak of S1 and S2 (AP₁₂) and the cardiac cycle ACC are 100% and 96.69%. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Zhang, Peng; Shang, Qingli; Ma, Jingxue; Hao, Yuhua; Ye, Cunxi
2017-03-20
To determine the correlation between the preoperative basal diameter of macular hole, the postoperative area of high autofluorescence (AF) in macula, and visual acuity in full-thickness macular hole. Forty-nine patients with full-thickness macular hole who underwent vitrectomy and C3F8 filling were reviewed. The preoperative diameter of macular hole, the 6 months postoperative area of high AF in macula if it existed, the length of inner segment/outer segment (IS/OS) defect, and visual acuity were obtained. The correlation between them was determined. At postoperative 6 months, the rate of high AF in macula was 63.3%. There were statistical differences between with and without high AF groups in postoperative best-corrected visual acuity (BCVA) (t = -2.751, p = 0.008), preoperative basal diameter of macular hole (t = -4.946, p = 0.00001), and postoperative length of IS/OS defect (t = -8.351, p<0.00001). Simple linear regression analysis showed high positive correlations between preoperative basal diameter of macular hole and area of high AF (p<0.00001, r = 0.893), postoperative length of IS/OS defect and area of high fundus AF (FAF) (p<0.00001, r = 0.779), and negative correlations between area of high AF and postoperative BCVA (p = 0.037, r = 0.375). There was low correlation between diameter of macular hole and postoperative BCVA (p = 0.112). The preoperative basal diameter of macular hole and postoperative length of IS/OS defect decides the postoperative area of high AF in macula to some degree, and the postoperative area of high AF in macula can be an evaluating indicator for poor macular function recovery.
Schouman, T; Schmitt, M; Adam, C; Dubois, G; Rouch, P
2016-06-01
The aim of this work was to assess the influence of reduction of the apparent mechanical properties of fully load-bearing porous titanium implants used in mandibular bone defects. Segmental 18mm long bone defects were created bilaterally in the lower jaws of adult ewes. One group of 6 ewes (group A) was treated with load-bearing 'rigid' (high stiffness) porous implants on the right side, and with control on the left side. A second group of 6 ewes (group B) was treated with 'flexible' porous and control implants exhibiting apparent mechanical properties ten times lower than the rigid implants. The mechanical behavior of the reconstructed hemi-mandibles was assessed by cantilever testing and bone ingrowth into the segmental defects was assessed by BV/TV measurement within the implant using micro-CT 12 weeks after implantation. A significantly higher rigidity was identified for porous implants compared with control implants at the anterior interface in group B. BV/TV of porous implants was significantly higher than that of control implants in group A. BV/TV differences were significant between porous and control implants in group B and were homogeneous along the main axis. Significantly higher BV/TV was identified in most sub-volumes of group B porous implants compared with group A. This work highlights the critical importance of the tuning of scaffolds to promote bone ingrowth with reference to the local strains occurring within the porous scaffold, which in this application was achieved using fully load-bearing low-stiffness porous titanium implants. Copyright © 2016 Elsevier Ltd. All rights reserved.
Saito, Takehisa; Narita, Norihiko; Yamada, Takechiyo; Ogi, Kazuhiro; Kanno, Masafumi; Manabe, Yasuhiro; Ito, Tetsufumi
2011-10-01
To evaluate the relationship between the length of nerve gap defects, incidence of nerve regeneration, and recovery of gustatory function after severing the chorda tympani nerve (CTN). Retrospective study. University hospital. Eighty-eight consecutive patients whose CTNs were severed during primary surgery and who underwent secondary surgery were included. Proximal and distal stumps of severed nerves were readapted or approximated during surgery. Therapeutic. Before and after surgery, the taste function was periodically evaluated using electrogustometry. Nerve gaps were classified into 4 groups: readaptation (Group 1), 1 to 3 mm (Group 2), 4 to 6 mm (Group 3), and more than 7 mm (Group 4). Regenerated nerves in the tympanic segment were detected in 36 (41%) of the 88 patients during secondary surgery. The incidence of nerve regeneration was 100% (10/10) in Group 1, 45% (10/22) in Group 2, 47% (9/19) in Group 3, and 19% (7/37) in Group 4. There was a significant difference between the length of nerve gap defects and incidence of nerve regeneration (p < 0.001). In the 36 patients with a regenerated CTN, the incidence of gustatory function recovery was 60% (6/10) in Group 1, 50% (5/10) in Group 2, 56% (5/9) in Group 3, and 43% (3/7) in Group 4. There was no significant difference between the length of nerve gap defects and incidence of taste function recovery. Reconstruction of a severed CTN is very important for regeneration. However, the regenerated CTN in the tympanic segment does not always reinnervate the fungiform papillae.
Likhitpanichkul, M.; Dreischarf, M.; Illien-Junger, S.; Walter, B. A.; Nukaga, T.; Long, R. G; Sakai, D.; Hecht, A. C.; Iatridis, J. C.
2015-01-01
Annulus fibrosus (AF) defects from annular tears, herniation, and discectomy procedures are associated with painful conditions and accelerated intervertebral disc (IVD) degeneration. Currently, no effective treatments exist to repair AF damage, restore IVD biomechanics and promote tissue regeneration. An injectable fibrin-genipin adhesive hydrogel (Fib-Gen) was evaluated for its performance repairing large AF defects in a bovine caudal IVD model using ex vivo organ culture and biomechanical testing of motion segments, and for its in vivo longevity and biocompatibility in a rat model by subcutaneous implantation. Fib-Gen sealed AF defects, prevented IVD height loss, and remained well-integrated with native AF tissue following approximately 14,000 cycles of compression in 6-day organ culture experiments. Fib-Gen repair also retained high viability of native AF cells near the repair site, reduced nitric oxide released to the media, and showed evidence of AF cell migration into the gel. Biomechanically, Fib-Gen fully restored compressive stiffness to intact levels validating organ culture findings. However, only partial restoration of tensile and torsional stiffness was obtained, suggesting opportunities to enhance this formulation. Subcutaneous implantation results, when compared with the literature, suggested Fib-Gen exhibited similar biocompatibility behaviour to fibrin alone but degraded much more slowly. We conclude that injectable Fib-Gen successfully sealed large AF defects, promoted functional restoration with improved motion segment biomechanics, and served as a biocompatible adhesive biomaterial that had greatly enhanced in vivo longevity compared to fibrin. Fib-Gen offers promise for AF repairs that may prevent painful conditions and accelerated degeneration of the IVD, and warrants further material development and evaluation. PMID:25036053
Likhitpanichkul, M; Dreischarf, M; Illien-Junger, S; Walter, B A; Nukaga, T; Long, R G; Sakai, D; Hecht, A C; Iatridis, J C
2014-07-18
Annulus fibrosus (AF) defects from annular tears, herniation, and discectomy procedures are associated with painful conditions and accelerated intervertebral disc (IVD) degeneration. Currently, no effective treatments exist to repair AF damage, restore IVD biomechanics and promote tissue regeneration. An injectable fibrin-genipin adhesive hydrogel (Fib-Gen) was evaluated for its performance repairing large AF defects in a bovine caudal IVD model using ex vivo organ culture and biomechanical testing of motion segments, and for its in vivo longevity and biocompatibility in a rat model by subcutaneous implantation. Fib-Gen sealed AF defects, prevented IVD height loss, and remained well-integrated with native AF tissue following approximately 14,000 cycles of compression in 6-day organ culture experiments. Fib-Gen repair also retained high viability of native AF cells near the repair site, reduced nitric oxide released to the media, and showed evidence of AF cell migration into the gel. Biomechanically, Fib-Gen fully restored compressive stiffness to intact levels validating organ culture findings. However, only partial restoration of tensile and torsional stiffness was obtained, suggesting opportunities to enhance this formulation. Subcutaneous implantation results, when compared with the literature, suggested Fib-Gen exhibited similar biocompatibility behaviour to fibrin alone but degraded much more slowly. We conclude that injectable Fib-Gen successfully sealed large AF defects, promoted functional restoration with improved motion segment biomechanics, and served as a biocompatible adhesive biomaterial that had greatly enhanced in vivo longevity compared to fibrin. Fib-Gen offers promise for AF repairs that may prevent painful conditions and accelerated degeneration of the IVD, and warrants further material development and evaluation.
Automated Analysis of CT Images for the Inspection of Hardwood Logs
Harbin Li; A. Lynn Abbott; Daniel L. Schmoldt
1996-01-01
This paper investigates several classifiers for labeling internal features of hardwood logs using computed tomography (CT) images. A primary motivation is to locate and classify internal defects so that an optimal cutting strategy can be chosen. Previous work has relied on combinations of low-level processing, image segmentation, autoregressive texture modeling, and...
7 CFR 51.1837 - Classification of defects.
Code of Federal Regulations, 2012 CFR
2012-01-01
... STANDARDS) United States Standards for Grades of Florida Tangerines Definitions § 51.1837 Classification of...) at stem end, or the equivalent of this amount, by volume, when occurring in other portions of the fruit Affecting all segments more than 1/4 inch (6.4 mm) at stem end, or the equivalent of this amount...
7 CFR 51.784 - Classification of defects.
Code of Federal Regulations, 2012 CFR
2012-01-01
... STANDARDS) United States Standards for Grades of Florida Grapefruit Definitions § 51.784 Classification of.... Dryness or mushy condition Affecting all segments more than 1/4 inch (6.4 mm) at stem end, or the... more than 1/2 inch (12.7 mm) at stem end, or the equivalent of this amount, by volume, when occurring...
7 CFR 51.1837 - Classification of defects.
Code of Federal Regulations, 2011 CFR
2011-01-01
... STANDARDS) United States Standards for Grades of Florida Tangerines Definitions § 51.1837 Classification of...) at stem end, or the equivalent of this amount, by volume, when occurring in other portions of the fruit Affecting all segments more than 1/4 inch (6.4 mm) at stem end, or the equivalent of this amount...
USDA-ARS?s Scientific Manuscript database
Thresholding is an important step in the segmentation of image features, and the existing methods are not all effective when the image histogram exhibits a unimodal pattern, which is common in defect detection of fruit. This study was aimed at developing a general automatic thresholding methodology ...
NASA Astrophysics Data System (ADS)
Hui, Wei-Hua; Bao, Fu-Ting; Wei, Xiang-Geng; Liu, Yang
2015-12-01
In this paper, a new measuring method of ablation rate was proposed based on X-ray three-dimensional (3D) reconstruction. The ablation of 4-direction carbon/carbon composite nozzles was investigated in the combustion environment of a solid rocket motor, and the macroscopic ablation and linear recession rate were studied through the X-ray 3D reconstruction method. The results showed that the maximum relative error of the X-ray 3D reconstruction was 0.0576%, which met the minimum accuracy of the ablation analysis; along the nozzle axial direction, from convergence segment, throat to expansion segment, the ablation gradually weakened; in terms of defect ablation, the middle ablation was weak, while the ablation in both sides was more serious. In a word, the proposed reconstruction method based on X-ray about C/C nozzle ablation can construct a clear model of ablative nozzle which characterizes the details about micro-cracks, deposition, pores and surface to analyze ablation, so that this method can create the ablation curve in any surface clearly.
An intelligent system for real time automatic defect inspection on specular coated surfaces
NASA Astrophysics Data System (ADS)
Li, Jinhua; Parker, Johné M.; Hou, Zhen
2005-07-01
Product visual inspection is still performed manually or semi automatically in most industries from simple ceramic tile grading to complex automotive body panel paint defect and surface quality inspection. Moreover, specular surfaces present additional challenge to conventional vision systems due to specular reflections, which may mask the true location of objects and lead to incorrect measurements. There are some sophisticated visual inspection methods developed in recent years. Unfortunately, most of them are highly computational. Systems built on those methods are either inapplicable or very costly to achieve real time inspection. In this paper, we describe an integrated low-cost intelligent system developed to automatically capture, extract, and segment defects on specular surfaces with uniform color coatings. The system inspects and locates regular surface defects with lateral dimensions as small as a millimeter. The proposed system is implemented on a group of smart cameras using its on-board processing ability to achieve real time inspection. The experimental results on real test panels demonstrate the effectiveness and robustness of proposed system.
Wang, Zhi-Yong; Wang, Jian-Wei; Qin, Li-Hua; Zhang, Wei-Guang; Zhang, Pei-Xun; Jiang, Bao-Guo
2018-06-01
To investigate the efficacy of chitin biological absorbable catheters in a rat model of autologous nerve transplantation. A segment of sciatic nerve was removed to produce a sciatic nerve defect, and the sural nerve was cut from the ipsilateral leg and used as a graft to bridge the defect, with or without use of a chitin biological absorbable catheter surrounding the graft. The number and morphology of regenerating myelinated fibers, nerve conduction velocity, nerve function index, triceps surae muscle morphology, and sensory function were evaluated at 9 and 12 months after surgery. All of the above parameters were improved in rats in which the nerve graft was bridged with chitin biological absorbable catheters compared with rats without catheters. The results of this study indicate that use of chitin biological absorbable catheters to surround sural nerve grafts bridging sciatic nerve defects promotes recovery of structural, motor, and sensory function and improves muscle fiber morphology. © 2018 John Wiley & Sons Ltd.
Burastero, Giorgio; Scarfì, Sonia; Ferraris, Chiara; Fresia, Chiara; Sessarego, Nadia; Fruscione, Floriana; Monetti, Francesco; Scarfò, Francesca; Schupbach, Peter; Podestà, Marina; Grappiolo, Guido; Zocchi, Elena
2010-07-01
Critical size segmental bone defects are still a major challenge in reconstructive orthopedic surgery. Transplantation of human mesenchymal stem cells (hMSC) has been proposed as an alternative to autogenous bone graft, as MSC can be expanded in vitro and induced to differentiate into bone-regenerating osteoblasts by several bone morphogenetic proteins (BMP). The aim of this study was to investigate whether the association of hMSC and BMP-7, with providing the necessary scaffold to fill the bone loss, improved bone regeneration in a rat model of critical size segmental bone defect, compared to treatment with either hMSC or BMP-7 and the matrix. In addition, we tested whether pre-treatment of hMSC with cyclic ADP-ribose (cADPR), an intracellular Ca2+ mobilizer previously shown to accelerate the in vitro expansion of hMSC (Scarfì S et al, Stem Cells, 2008), affected the osteoinductive capacity of the cells in vivo. X-ray analysis, performed 2, 10 and 16 weeks after transplantation, revealed a significantly higher score in the rats treated with hMSC and BMP-7 compared to controls, receiving either hMSC or BMP-7. Microtomography and histological analysis, performed 16weeks after transplantation, confirmed the improved bone regeneration in the animals treated with the association of hMSC and BMP-7 compared to controls. Pre-treatment with cADPR to stimulate hMSC proliferation in vitro did not affect the bone regenerating capacity of the cells in vivo. These results indicate that the association of in vitro expanded hMSC with BMP-7 provide a better osteoinductive graft compared to either hMSC or BMP-7 alone. Moreover, cADPR may be used to stimulate hMSC proliferation in vitro in order to reduce the time required to obtain a transplantable number of cells, with no adverse effect on the bone regenerating capacity of hMSC. 2010 Elsevier Inc. All rights reserved.
Mobbs, Ralph J; Coughlan, Marc; Thompson, Robert; Sutterlin, Chester E; Phan, Kevin
2017-04-01
OBJECTIVE There has been a recent renewed interest in the use and potential applications of 3D printing in the assistance of surgical planning and the development of personalized prostheses. There have been few reports on the use of 3D printing for implants designed to be used in complex spinal surgery. METHODS The authors report 2 cases in which 3D printing was used for surgical planning as a preoperative mold, and for a custom-designed titanium prosthesis: one patient with a C-1/C-2 chordoma who underwent tumor resection and vertebral reconstruction, and another patient with a custom-designed titanium anterior fusion cage for an unusual congenital spinal deformity. RESULTS In both presented cases, the custom-designed and custom-built implants were easily slotted into position, which facilitated the surgery and shortened the procedure time, avoiding further complex reconstruction such as harvesting rib or fibular grafts and fashioning these grafts intraoperatively to fit the defect. Radiological follow-up for both cases demonstrated successful fusion at 9 and 12 months, respectively. CONCLUSIONS These cases demonstrate the feasibility of the use of 3D modeling and printing to develop personalized prostheses and can ease the difficulty of complex spinal surgery. Possible future directions of research include the combination of 3D-printed implants and biologics, as well as the development of bioceramic composites and custom implants for load-bearing purposes.
[Clinical significance of myocardial 123I-BMIPP imaging in patients with myocardial infarction].
Narita, M; Kurihara, T; Shindoh, T; Honda, M
1997-03-01
In order to clarify the characteristics of fatty acid metabolism in patients with myocardial infarction (MI), we performed myocardial imaging with 123I-beta-methyl-p-iodophenylpentadecanoic acid (BMIPP) and we compared these findings with exercise stress (Ex) and resting myocardial perfusion imaging with 99mTc-methoxyisobutylisonitrile (MIBI) and left ventricular wall motion index (WMI) which were obtained by left ventriculography. We studied 55 patients with MI, 14 patients with recent MI (RMI) and 41 patients with old MI (OMI), and myocardial images were divided into 17 segments and myocardial uptake of the radionuclide was graded from 0 (normal) to 3 (maximal abnormality). In 28 patients we compared segmental defect score (SDS) with WMI which were obtained by centerline method at the corresponded segments. As a whole, the mean total defect scores (TDSs) of BMIPP and Ex were similar and they were greater than the mean TDS of resting perfusion. In 30 patient (55%) TDS of BMIPP was greater than that of TDS of resting perfusion. In 24 patients perfusion abnormality developed by Ex and the location of BMIPP abnormality coincided with the abnormality of Ex. But in the other 6 patients Ex did not induce any abnormality and they were all RMI and infarcted coronary artery was patent. However in the group with TDS of BMIPP identical to TDS of resting perfusion (25 patients), 92% did not show myocardial perfusion abnormality after Ex. In the comparison of SDS and WMI, myocardial segments were divided into 3 groups; both SDSs of BMIPP and resting perfusion were normal or borderline abnormality (Group 1, 82 segments), SDS of resting perfusion was normal or borderline and SDS of BMIPP was definitely abnormal (Group 2, 10 segments) and both SDSs of BMIPP and resting perfusion were definitely abnormal (Group 3, 48 segments). In Group 1, WMS (-0.41 +/- 0.77) was significantly (p < 0.001) greater than those of Group 2 (-2.14 +/- 0.50) and Group 3 (-2.32 +/- 0.67). But there was no difference between Group 2 and 3. These findings suggested that in the segments with mismatch between BMIPP and resting perfusion reflects stunned myocardium. These results suggested that in half of the patients with MI, abnormal fatty acid metabolism may appear in viable myocardium such as jeopardized myocardium and myocardium which recently recovered from severe ischemia like acute MI and BMIPP imaging was useful to know the history of myocardial ischemia.
Sheng, Yuewen; Wang, Xiaochen; Fujisawa, Kazunori; Ying, Siqi; Elias, Ana Laura; Lin, Zhong; Xu, Wenshuo; Zhou, Yingqiu; Korsunsky, Alexander M; Bhaskaran, Harish; Terrones, Mauricio; Warner, Jamie H
2017-05-03
We show that hexagonal domains of monolayer tungsten disulfide (WS 2 ) grown by chemical vapor deposition (CVD) with powder precursors can have discrete segmentation in their photoluminescence (PL) emission intensity, forming symmetric patterns with alternating bright and dark regions. Two-dimensional maps of the PL reveal significant reduction within the segments associated with the longest sides of the hexagonal domains. Analysis of the PL spectra shows differences in the exciton to trion ratio, indicating variations in the exciton recombination dynamics. Monolayers of WS 2 hexagonal islands transferred to new substrates still exhibit this PL segmentation, ruling out local strain in the regions as the dominant cause. High-power laser irradiation causes preferential degradation of the bright segments by sulfur removal, indicating the presence of a more defective region that is higher in oxidative reactivity. Atomic force microscopy (AFM) images of topography and amplitude modes show uniform thickness of the WS 2 domains and no signs of segmentation. However, AFM phase maps do show the same segmentation of the domain as the PL maps and indicate that it is caused by some kind of structural difference that we could not clearly identify. These results provide important insights into the spatially varying properties of these CVD-grown transition metal dichalcogenide materials, which may be important for their effective implementation in fast photo sensors and optical switches.
Resonant Raman scattering of controlled molecular weight polyacetylene
NASA Astrophysics Data System (ADS)
Schen, M. A.; Chien, J. C. W.; Perrin, E.; Lefrant, S.; Mulazzi, E.
1988-12-01
Polyacetylene, (CH)x, films of 500, 5300, 10 500, and 100 000 Daltons number average molecular weights (Mn ) were synthesized using the titanium tetra-n-butoxide/triethyl aluminum-catalyst/cocatalyst system and examined using resonant Raman scattering techniques. Before isomerization, trans segments are found to exist mainly as short, isolated sequences independent of Mn. After thermal isomerization, theoretical analysis of the RRS spectra using the Brivio, Mulazzi model indicate the ratio of long trans conjugated segments (N≥30) to short trans conjugated segments (N≤30) is significantly larger for 100 000 Dalton polymer in comparison to polymer of 10 500 Mn and below. For samples below 10 500 Daltons, no clear relationship between actual polymer molecular weight and G is observed. Optimization of the isomerization conditions for 100 000 Dalton polymer results in trans-(CH)x with a G=0.80. These results suggest that not until very long molecular chains are obtained can samples composed principally of long conjugated segments be obtained. It is proposed that defects which arise during and after the polymerization limit the content of long segments. Ambient, short term oxidation of 100 000 Mn polymer shows a decrease in G from 0.80 to 0.70. Low level chain oxidation or doping is shown to preferentially occur within long conjugated segments.
NASA Astrophysics Data System (ADS)
Kuo, Chung-Feng Jeffrey; Lai, Chun-Yu; Kao, Chih-Hsiang; Chiu, Chin-Hsun
2018-05-01
In order to improve the current manual inspection and classification process for polarizing film on production lines, this study proposes a high precision automated inspection and classification system for polarizing film, which is used for recognition and classification of four common defects: dent, foreign material, bright spot, and scratch. First, the median filter is used to remove the impulse noise in the defect image of polarizing film. The random noise in the background is smoothed by the improved anisotropic diffusion, while the edge detail of the defect region is sharpened. Next, the defect image is transformed by Fourier transform to the frequency domain, combined with a Butterworth high pass filter to sharpen the edge detail of the defect region, and brought back by inverse Fourier transform to the spatial domain to complete the image enhancement process. For image segmentation, the edge of the defect region is found by Canny edge detector, and then the complete defect region is obtained by two-stage morphology processing. For defect classification, the feature values, including maximum gray level, eccentricity, the contrast, and homogeneity of gray level co-occurrence matrix (GLCM) extracted from the images, are used as the input of the radial basis function neural network (RBFNN) and back-propagation neural network (BPNN) classifier, 96 defect images are then used as training samples, and 84 defect images are used as testing samples to validate the classification effect. The result shows that the classification accuracy by using RBFNN is 98.9%. Thus, our proposed system can be used by manufacturing companies for a higher yield rate and lower cost. The processing time of one single image is 2.57 seconds, thus meeting the practical application requirement of an industrial production line.
Tissue specific mutagenic and carcinogenic responses in NER defective mouse models.
Wijnhoven, Susan W P; Hoogervorst, Esther M; de Waard, Harm; van der Horst, Gijsbertus T J; van Steeg, Harry
2007-01-03
Several mouse models with defects in genes encoding components of the nucleotide excision repair (NER) pathway have been developed. In NER two different sub-pathways are known, i.e. transcription-coupled repair (TC-NER) and global-genome repair (GG-NER). A defect in one particular NER protein can lead to a (partial) defect in GG-NER, TC-NER or both. GG-NER defects in mice predispose to cancer, both spontaneous as well as UV-induced. As such these models (Xpa, Xpc and Xpe) recapitulate the human xeroderma pigmentosum (XP) syndrome. Defects in TC-NER in humans are associated with Cockayne syndrome (CS), a disease not linked to tumor development. Mice with TC-NER defects (Csa and Csb) are - except for the skin - not susceptible to develop (carcinogen-induced) tumors. Some NER factors, i.e. XPB, XPD, XPF, XPG and ERCC1 have functions outside NER, like transcription initiation and inter-strand crosslink repair. Deficiencies in these processes in mice lead to very severe phenotypes, like trichothiodystrophy (TTD) or a combination of XP and CS. In most cases these animals have a (very) short life span, display segmental progeria, but do not develop tumors. Here we will overview the available NER-related mouse models and will discuss their phenotypes in terms of (chemical-induced) tissue-specific tumor development, mutagenesis and premature aging features.
Luo, Danmei; Rong, Qiguo; Chen, Quan
2017-09-01
Reconstruction of segmental defects in the mandible remains a challenge for maxillofacial surgery. The use of porous scaffolds is a potential method for repairing these defects. Now, additive manufacturing techniques provide a solution for the fabrication of porous scaffolds with specific geometrical shapes and complex structures. The goal of this study was to design and optimize a three-dimensional tetrahedral titanium scaffold for the reconstruction of mandibular defects. With a fixed strut diameter of 0.45mm and a mean cell size of 2.2mm, a tetrahedral structural porous scaffold was designed for a simulated anatomical defect derived from computed tomography (CT) data of a human mandible. An optimization method based on the concept of uniform stress was performed on the initial scaffold to realize a minimal-weight design. Geometric and mechanical comparisons between the initial and optimized scaffold show that the optimized scaffold exhibits a larger porosity, 81.90%, as well as a more homogeneous stress distribution. These results demonstrate that tetrahedral structural titanium scaffolds are feasible structures for repairing mandibular defects, and that the proposed optimization scheme has the ability to produce superior scaffolds for mandibular reconstruction with better stability, higher porosity, and less weight. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
Thermal activation of dislocations in large scale obstacle bypass
NASA Astrophysics Data System (ADS)
Sobie, Cameron; Capolungo, Laurent; McDowell, David L.; Martinez, Enrique
2017-08-01
Dislocation dynamics simulations have been used extensively to predict hardening caused by dislocation-obstacle interactions, including irradiation defect hardening in the athermal case. Incorporating the role of thermal energy on these interactions is possible with a framework provided by harmonic transition state theory (HTST) enabling direct access to thermally activated reaction rates using the Arrhenius equation, including rates of dislocation-obstacle bypass processes. Moving beyond unit dislocation-defect reactions to a representative environment containing a large number of defects requires coarse-graining the activation energy barriers of a population of obstacles into an effective energy barrier that accurately represents the large scale collective process. The work presented here investigates the relationship between unit dislocation-defect bypass processes and the distribution of activation energy barriers calculated for ensemble bypass processes. A significant difference between these cases is observed, which is attributed to the inherent cooperative nature of dislocation bypass processes. In addition to the dislocation-defect interaction, the morphology of the dislocation segments pinned to the defects play an important role on the activation energies for bypass. A phenomenological model for activation energy stress dependence is shown to describe well the effect of a distribution of activation energies, and a probabilistic activation energy model incorporating the stress distribution in a material is presented.
Roffi, Alice; Krishnakumar, Gopal Shankar; Gostynska, Natalia; Kon, Elizaveta; Candrian, Christian; Filardo, Giuseppe
2017-01-01
Long bone defects represent a clinical challenge. Bone tissue engineering (BTE) has been developed to overcome problems associated with conventional methods. The aim of this study was to assess the BTE strategies available in preclinical and clinical settings and the current evidence supporting this approach. A systematic literature screening was performed on PubMed database, searching for both preclinical (only on large animals) and clinical studies. The following string was used: "(Scaffold OR Implant) AND (Long bone defect OR segmental bone defect OR large bone defect OR bone loss defect)." The search retrieved a total of 1573 articles: 51 preclinical and 4 clinical studies were included. The great amount of preclinical papers published over the past few years showed promising findings in terms of radiological and histological evidence. Unfortunately, this in vivo situation is not reflected by a corresponding clinical impact, with few published papers, highly heterogeneous and with small patient populations. Several aspects should be further investigated to translate positive preclinical findings into clinical protocols: the identification of the best biomaterial, with both biological and biomechanical suitable properties, and the selection of the best choice between cells, GFs, or their combination through standardized models to be validated by randomized trials.
NASA Astrophysics Data System (ADS)
Forte, Paulo M. F.; Felgueiras, P. E. R.; Ferreira, Flávio P.; Sousa, M. A.; Nunes-Pereira, Eduardo J.; Bret, Boris P. J.; Belsley, Michael S.
2017-01-01
An automatic optical inspection system for detecting local defects on specular surfaces is presented. The system uses an image display to produce a sequence of structured diffuse illumination patterns and a digital camera to acquire the corresponding sequence of images. An image enhancement algorithm, which measures the local intensity variations between bright- and dark-field illumination conditions, yields a final image in which the defects are revealed with a high contrast. Subsequently, an image segmentation algorithm, which compares statistically the enhanced image of the inspected surface with the corresponding image for a defect-free template, allows separating defects from non-defects with an adjusting decision threshold. The method can be applied to shiny surfaces of any material including metal, plastic and glass. The described method was tested on the plastic surface of a car dashboard system. We were able to detect not only scratches but also dust and fingerprints. In our experiment we observed a detection contrast increase from about 40%, when using an extended light source, to more than 90% when using a structured light source. The presented method is simple, robust and can be carried out with short cycle times, making it appropriate for applications in industrial environments.
NRC/AMRMC Resident Research Associateship Program
2015-03-01
antimicrobials (and antiseptics) as well as to evaluate the effectiveness of various biofilm dispersal agents utilizing a number of bacterial species as...combat related wounds. 3 Demonstrated the utility of combinations of biofilm dispersal agents and antimicrobials as an alternate therapy for...alone or in combination with antimicrobials ) to reduce infection in contaminated femoral segmental defects. 5 Characterized host responses of
Tschernutter, M; Schlichtenbrede, F C; Howe, S; Balaggan, K S; Munro, P M; Bainbridge, J W B; Thrasher, A J; Smith, A J; Ali, R R
2005-04-01
The Royal College of Surgeons (RCS) rat is a well-characterized model of autosomal recessive retinitis pigmentosa (RP) due to a defect in the retinal pigment epithelium (RPE). It is homozygous for a null mutation in the gene encoding , a receptor tyrosine kinase found in RPE cells, that is required for phagocytosis of shed photoreceptor outer segments. The absence of Mertk results in accumulation of outer segment debris. This subsequently leads to progressive loss of photoreceptor cells. In order to evaluate the efficacy of lentiviral-mediated gene replacement therapy in the RCS rat, we produced recombinant VSV-G pseudotyped HIV-1-based lentiviruses containing a murine Mertk cDNA driven by a spleen focus forming virus (SFFV) promoter. The vector was subretinally injected into the right eye of 10-day-old RCS rats; the left eye was left untreated as an internal control. Here, we present a detailed assessment of the duration and extent of the morphological rescue and the resulting functional benefits. We examined animals at various time points over a period of 7 months by light and electron microscopy, and electroretinography. We observed correction of the phagocytic defect, slowing of photoreceptor cell loss and preservation of retinal function for up to 7 months. This study demonstrates the potential of gene therapy approaches for the treatment of retinal degenerations caused by defects specific to the RPE and supports the use of lentiviral vectors for the treatment of such disorders.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Colak, Evrim; Serebryannikov, Andriy E., E-mail: andser@amu.edu.pl; Usik, P. V.
2016-05-21
It is shown that strong diffractions and related dual-beam splitting can be obtained at transmission through the nonsymmetric structures that represent two slabs of photonic crystal (PhC) separated by a single coupled-cavity type defect layer, while there are no grating-like corrugations at the interfaces. The basic operation regimes include unidirectional and bidirectional splitting that occur due to the dominant contribution of the first positive and first negative diffraction orders to the transmission, which is typically connected with different manifestations of the asymmetric transmission phenomenon. Being the main component of the resulting transmission mechanism, diffractions appear owing to the effect exertedmore » by the defect layer that works like an embedded diffractive element. Two mechanisms can co-exist in one structure, which differ, among others, in that whether dispersion allows coupling of zero order to a wave propagating in the regular, i.e., defect-free PhC segments or not. The possibility of strong diffractions and efficient splitting related to it strongly depend on the dispersion properties of the Floquet-Bloch modes of the PhC. Existence of one of the studied transmission scenarios is not affected by location of the defect layer.« less
Prevalence of birth defects among American-Indian births in California, 1983-2010.
Aggarwal, Deepa; Warmerdam, Barbara; Wyatt, Katrina; Ahmad, Shabbir; Shaw, Gary M
2015-02-01
Approximately 6.3 million live births and fetal deaths occurred during the ascertainment period in the California Birth Defects Monitoring Program registry. American-Indian and non-Hispanic white women delivered 40,268 and 2,044,118 births, respectively. While much information has been published about non-Hispanic white infants, little is known regarding the risks of birth defects among infants born to American-Indian women. This study used data from the California Birth Defects Monitoring Program to explore risks of selected birth defects in offspring of American-Indian relative to non-Hispanic white women in California. The study population included all live births and fetal deaths 20 weeks or greater from 1983 to 2010. Prevalence ratios and corresponding 95% confidence intervals (CI) were computed using Poisson regression for 51 groupings of birth defects. Prevalence ratios were estimated for 51 groupings of birth defects. Of the 51, nine had statistically precise results ranging from 0.78 to 1.85. The eight groups with elevated risks for American-Indian births were reduction deformities of brain, anomalies of anterior segments, specified anomalies of ear, ostium secundum type atrial septal defect, specified anomalies of heart, anomalies of the aorta, anomalies of great veins, and cleft lip with cleft palate. Our results suggest that American-Indian women having babies in California may be at higher risk for eight birth defect phenotypes compared with non-Hispanic whites. Further research is needed to determine whether these risks are observed among other populations of American-Indian women or when adjusted for potential covariates. © 2015 Wiley Periodicals, Inc.
INHIBITION OF BONE GROWTH AS A COMPLICATION OF RADIUM THERAPY (in Russian)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shimanovskaya, K.B.
1961-08-01
S>Information is given on radiation injuries of the bone and teeth following repeated use of therapeutic doses of radiation in 20 persons: in 19 after treatment of skin angiomas of the face and chest, and in 1 after treating Ewing's sarcoma of the fibular bone. In 10 patients the changes in the bones were coupled with the presence of atrophy, teleangiectasis, and depigmentation of the skin over the changed bone. (auth)
Resection arthrodesis for giant cell tumors around the knee
Kapoor, Sudhir K; Tiwari, Akshay
2007-01-01
Background: Giant cell tumors (GCTs) of bone are aggressive benign tumors. Wide resection is reserved for a small subset of patients with biologically more aggressive, recurrent and extensive tumors. As the patients affected with GCT are young or middle-aged adults with a normal life expectancy, arthrodesis is an attractive option for reconstruction in these patients. Materials and Methods: Thirty-six patients of mean age 33.1 years with Campanacci Grade III giant cell tumors around the knee (20 distal femoral and 16 proximal tibial) were treated with wide resection and arthrodesis from January 1996 through January 2006. Arthrodesis was performed using plating with free fibular graft (n = 18), IM nail with free fibular graft (n = 8) and IM nail combined with ring fixator using bone transport (n = 10). Results: Fusion after the first surgery was achieved in 77.7%, 75% and 90% of the patients in the three groups respectively. Local recurrence was seen in two patients and repeat surgery for nonunion/ graft fracture had to be done in four patients and two patients in the plating and nailing groups respectively. Conclusion: Wide resection and arthrodesis in aggressive GCTs around the knee is a good treatment option. IM nail combined with a ring fixator seems to be a good method of arthrodesis with high fusion rates, least shortening and early rehabilitation. PMID:21139764
Lubberts, Bart; Guss, Daniel; Vopat, Bryan G; Wolf, Jonathon C; Moon, Daniel K; DiGiovanni, Christopher W
2017-12-01
To assist with visualization, orthopaedic surgeons often apply ankle distraction during arthroscopic procedures. The study aimed to investigate whether ankle distraction suppresses fibular motion in cadaveric specimens with an unstable syndesmotic injury. Fourteen fresh-frozen above knee specimens underwent arthroscopic assessment with 1) intact ligaments, 2) after sectioning of the anterior inferior tibiofibular ligament, the interosseous ligament, and the posterior inferior tibiofibular ligament, and 3) after sectioning of the deep and superficial deltoid ligament. In all scenarios, the lateral hook test, anterior-posterior hook test, and posterior-anterior hook test were applied. Each test was performed with and without ankle distraction. Coronal plane anterior and posterior tibiofibular diastasis as well as sagittal plane tibiofibular translation due to the applied load were arthroscopically measured. Tibiofibular diastasis in the coronal plane, as measured at both the anterior and posterior third of the incisura, was found to be significantly less when ankle distraction was applied, as compared to arthroscopic evaluation in the absence of distraction. In contrast, measurement of sagittal plane tibiofibular translation was not affected by ankle distraction. Since arthroscopic findings of syndesmotic instability are subtle the differential values of the syndesmotic measurements taken on and off distraction are clinically relevant. To optimally assess syndesmotic instability one should evaluate the syndesmosis without distraction or focus on fibular motion in the sagittal plane when distraction is required. Copyright © 2017 Elsevier Ltd. All rights reserved.
Rommel, Niklas; Kesting, Marco Rainer; Rohleder, Nils Hagen; Bauer, Florian Martin Josef; Wolff, Klaus-Dietrich; Weitz, Jochen
2017-08-01
The free osteomyocutaneous fibular flap has become one of the primary options for mandibular reconstruction, because of the later introduction and development of virtual surgical planning (VSP). However, VSP is associated with high additional pre-operative effort and costs. Therefore, the purpose of the study was to develop a new individual cost-effective pre-operative planning concept for free fibula mandible reconstruction and to compare it with VSP regarding clinical parameters and post-operative outcome. 31 patients undergoing mandibular reconstruction with a microvascular free fibular flap were divided into two groups and retrospectively reviewed. For the first group A (18 of 31 patients), an individual method with stererolithographic (STL) models, silicon templates and hand-made cutting guides was used (about 250 € planning costs/patient). For the second group B (13 of 31 patients), VSP including pre-fabricated cutting guides was used (about 2500 € planning costs/patient). We found no statistically significant differences with respect to intra-operative time of mandibular reconstruction, duration of hospitalisation or post-operative complications between the two groups (p ≥ 0.05). The surgical outcomes and operative efficiency of this individual and cost-effective planning concept are comparable with the much more expensive complete VSP concept. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Sun, Tao; Wang, Lingxiang; Guo, Changzhi; Zhang, Guochuan; Hu, Wenhai
2017-05-02
Malignant tumors in the proximal fibula are rare but life-threatening; however, biopsy is not routine due to the high risk of peroneal nerve injury. Our aim was to determine preoperative clinical indicators of malignancy. Between 2004 and 2016, 52 consecutive patients with proximal fibular tumors were retrospectively reviewed. Details of the clinicopathological characteristics including age, gender, location of tumors, the presenting symptoms, the duration of symptoms, and pathological diagnosis were collected. Descriptive statistics were calculated, and univariate and multivariate regression were performed. Of these 52 patients, 84.6% had benign tumors and 15.4% malignant tumors. The most common benign tumors were osteochondromas (46.2%), followed by enchondromas (13.5%) and giant cell tumors (13.5%). The most common malignancy was osteosarcomas (11.5%). The most common presenting symptoms were a palpable mass (52.0%) and pain (46.2%). Pain was the most sensitive (100%) and fourth specific (64%); both high skin temperature and peroneal nerve compression had the highest specificity (98%) and third sensitivity (64%); change in symptoms had the second highest specificity (89%) while 50% sensitivity. Using multivariate regression, palpable pain, high skin temperature, and peroneal nerve compression symptoms were predictors of malignancy. Most tumors in the proximal fibula are benign, and the malignancy is rare. Palpable pain, peroneal nerve compression symptoms, and high skin temperature were specific in predicting malignancy.
English, Arthur W.; Cucoranu, Delia; Mulligan, Amanda; Sabatier, Manning
2009-01-01
We investigated the extent of misdirection of regenerating axons when that regeneration was enhanced using treadmill training. Retrograde fluorescent tracers were applied to the cut proximal stumps of the tibial and common fibular nerves two or four weeks after transection and surgical repair of the mouse sciatic nerve. The spatial locations of retrogradely labeled motoneurons were studied in untreated control mice and in mice receiving two weeks of treadmill training, either according to a continuous protocol (10 m/min, one hour/day, five day/week) or an interval protocol (20 m/min for two minutes, followed by a five minute rest, repeated 4 times, five days/week). More retrogradely labeled motoneurons were found in both treadmill trained groups. The magnitude of this increase was as great as or greater than that found after using other enhancement strategies. In both treadmill trained groups, the proportions of motoneurons labeled from tracer applied to the common fibular nerve that were found in spinal cord locations reserved for tibial motoneurons in intact mice was no greater than in untreated control mice and significantly less than found after electrical stimulation or chondroitinase treatment. Treadmill training in the first two weeks following peripheral nerve injury produces a marked enhancement of motor axon regeneration without increasing the propensity of those axons to choose pathways leading to functionally inappropriate targets. PMID:19731339
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ghanem, N.; Costes, B.; Girodon, E.
1994-05-15
To determine cystic fibrosis (CF) defects in a sample of 224 non-[Delta]F508 CF chromosomes, the authors used denaturing gradient gel multiplex analysis of CF transmembrane conductance regulator gene segments, a strategy based on blind exhaustive analysis rather than a search for known mutations. This process allowed detection of 11 novel variations comprising two nonsense mutations (Q890X and W1204X), a splice defect (405 + 4 A [yields] G), a frameshift (3293delA), four presumed missense mutations (S912L, H949Y, L1065P, Q1071P), and three sequence polymorphisms (R31C or 223 C/T, 3471 T/C, and T1220I or 3791 C/T). The authors describe these variations, together withmore » the associated phenotype when defects on both CF chromosomes were identified. 8 refs., 1 fig., 1 tab.« less
NRC/AMRMC Resident Research Associateship Program
2015-03-01
antimicrobials (and antiseptics) as well as to evaluate the effectiveness of various biofilm dispersal agents utilizing a number of bacterial species as well...combat related wounds. 3 Demonstrated the utility of combinations of biofilm dispersal agents and antimicrobials as an alternate therapy for targeting...alone or in combination with antimicrobials ) to reduce infection in contaminated femoral segmental defects. 5 Characterized host responses of
Optimizing Soft Tissue Management and Spacer Design in Segmental Bone Defects
2015-10-01
were found with Tukey’s HSD post hoc analysis. Several target genes such as Oct4, Sox2, TGFB, and Col1A1 were generally up-regulated in all sections...samples presented several upregulated target genes such as Oct4, Sox2, TGFB, and Col1A1 in all sections. No significant main effects were found for
A Silvicultural Evaluation of Four Methods of Marking Second-growth Northern Hardwood Stands
Rodney D. Jacobs
1966-01-01
Second-growth northern hardwood stands occupy an important segment of the commercial forest land of Upper Michigan and northern Wisconsin. The size- and age-class distributions and species composition of these stands vary considerably, but under all conditions most of the trees are highly defective or poorly formed or of an undesirable species. Forest managers...
Königsmann, Tatiana; Turetzek, Natascha; Pechmann, Matthias; Prpic, Nikola-Michael
2017-11-01
Zinc finger transcription factors of the Sp6-9 group are evolutionarily conserved in all metazoans and have important functions in, e.g., limb formation and heart development. The function of Sp6-9-related genes has been studied in a number of vertebrates and invertebrates, but data from chelicerates (spiders and allies) was lacking so far. We have isolated the ortholog of Sp6-9 from the common house spider Parasteatoda tepidariorum and the cellar spider Pholcus phalangioides. We show that the Sp6-9 gene in these spider species is expressed in the developing appendages thus suggesting a conserved role in limb formation. Indeed, RNAi with Sp6-9 in P. tepidariorum leads not only to strong limb defects, but also to the loss of body segments and head defects in more strongly affected animals. Together with a new expression domain in the early embryo, these data suggest that Sp6-9 has a dual role P. tepidariorum. The early role in head and body segment formation is not known from other arthropods, but the role in limb formation is evolutionarily highly conserved.
Aurégan, Jean-Charles; Bégué, Thierry; Rigoulot, Guillaume; Glorion, Christophe; Pannier, Stéphanie
2016-12-01
The induced membrane technique was designed by Masquelet et al. to address segmental bone defects of critical size in adults. It has been used after bone defects of traumatic, infectious and tumoral origin with satisfactory results. Recently, it has been used in children but, after an initial enthusiasm, several cases of failure have been reported. The purpose of this study was to assess the success rate and the risk factors of failure of the induced membrane for children. We conducted a systematic review of all the studies reporting the results of the induced membrane technique to address bone defects of critical size in children. Our primary outcome was the success rate of the technique defined as a bone union before any iterative surgery. Our secondary outcomes were the complications and the risk factors of failure. We searched Medline via Pubmed, EMBASE and the Cochrane Library. Twelve studies, including 69 patients, met the inclusion criteria. There were 41 boys and 28 girls. Mean age at surgery was 10 years. Mean size of resection was 12.38 cm and the mean time between the two stages was 5.86 months. Mean rate of bone union after the two stages of the induced membrane technique was 58% (40/69) but this rate increased to 87% after revision surgeries (60/69). Main complications were non-unions (19/69), lysis of the graft (6/69) and fractures of the bone graft (6/69). Only 1/69 deep infection was reported. Other non specific complications were regularly reported such limb length discrepancies, joint stiffness and protruding wires. Risk factor of failure that could be suspected comprised the resection of a malignant tumour, a bone defect located at the femur, a wide resection, a long time between the two stages, an unstable osteosynthesis and a bone graft associating autograft to other graft materials. The induced membrane technique is suitable for bone defects of critical size in children. It is a reliable technique with no need of micro vascular surgery. However, we found several risk factors of failure for the use of the induced membrane technique to address segmental bone defect of critical size in children. Copyright © 2016 Elsevier Ltd. All rights reserved.
Mei, Mei; Yang, Lin; Zhan, Guodong; Wang, Huijun; Ma, Duan; Zhou, Wenhao; Huang, Guoying
2014-06-01
To screen for genomic copy number variations (CNVs) in two unrelated neonates with multiple congenital abnormalities using Affymetrix SNP chip and try to find the critical region associated with congenital heart disease. Two neonates were tested for genomic copy number variations by using Cytogenetic SNP chip.Rare CNVs with potential clinical significance were selected of which deletion segments' size was larger than 50 kb and duplication segments' size was larger than 150 kb based on the analysis of ChAs software, without false positive CNVs and segments of normal population. The identified CNVs were compared with those of the cases in DECIPHER and ISCA databases. Eleven rare CNVs with size from 546.6-27 892 kb were identified in the 2 neonates. The deletion region and size of case 1 were 8p23.3-p23.1 (387 912-11 506 771 bp) and 11.1 Mb respectively, the duplication region and size of case 1 were 8p23.1-p11.1 (11 508 387-43 321 279 bp) and 31.8 Mb respectively. The deletion region and size of case 2 were 8p23.3-p23.1 (46 385-7 809 878 bp) and 7.8 Mb respectively, the duplication region and size of case 2 were 8p23.1-p11.21 (12 260 914-40 917 092 bp) and 28.7 Mb respectively. The comparison with Decipher and ISCA databases supported previous viewpoint that 8p23.1 had been associated with congenital heart disease and the region between 7 809 878-11 506 771 bp may play a role in the severe cardiac defects associated with 8p23.1 deletions. Case 1 had serious cardiac abnormalities whose GATA4 was located in the duplication segment and the copy number increased while SOX7 was located in the deletion segment and the copy number decreased. The region between 7 809 878-11 506 771 bp in 8p23.1 is associated with heart defects and copy number variants of SOX7 and GATA4 may result in congenital heart disease.
Papadopoulos, P; Floudas, G; Schnell, I; Lieberwirth, I; Nguyen, T Q; Klok, H-A
2006-02-01
The structure and the associated dynamics of a series of poly(gamma-benzyl-L-glutamate)-b-poly(dimethyl siloxane)-b-poly(gamma-benzyl-L-glutamate) (PBLG-b-PDMS-b-PBLG) triblock copolymers were investigated using small- and wide-angle X-ray scattering, NMR, transmission electron microscopy, and dielectric spectroscopy, respectively. The structural analysis revealed phase separation in the case of the longer blocks with defected alpha-helical segments embedded within the block copolymer nanodomains. The alpha-helical persistence length was found to depend on the degree of segregation; thermodynamic confinement and chain stretching results in the partial annihilation of helical defects.
Molday, Robert S; Molday, Laurie L; Loewen, Christopher J R
2004-01-01
Peripherin 2 is a photoreceptor-specific membrane protein implicated in outer segment disk morphogenesis and linked to various retinopathies including autosomal dominant retinitis pigmentosa (ADRP). Peripherin 2 and ROM1 assemble as a mixture of core noncovalent homomeric and heteromeric tetramers that further link together through disulfide bonds to form higher order oligomers. These complexes are critical for disk rim formation and outer segment structure through interaction with the cGMP-gated channel and other photoreceptor proteins. We have examined the role of subunit assembly in peripherin 2 targeting to disks, outer segment structure, and photoreceptor degeneration by examining molecular and cellular properties of peripherin 2 mutants in COS-1 cells and transgenic Xenopus laevis rod photoreceptors. Wild-type (WT) and the ADRP-linked P216L mutant were transported and incorporated into newly formed outer segment disks of transgenic X. laevis. The P216L mutant, however, induced progressive outer segment instability and photoreceptor degeneration possibly through the introduction of a new N-linked oligosaccharide chain. In contrast, the C214S and L185P disease-linked, tetramerization-defective mutants, were retained in the inner segment, but did not affect outer segment structure or induce photoreceptor degeneration. Together, these results indicate that peripherin 2 mutations can cause ADRP either through a deficiency in WT peripherin 2 (C214S, 1.185P) or by a dominant negative effect on disk stability (P216L).
Le Faivre, Julien; Duhamel, Alain; Khung, Suonita; Faivre, Jean-Baptiste; Lamblin, Nicolas; Remy, Jacques; Remy-Jardin, Martine
2016-11-01
To evaluate the impact of CT perfusion imaging on the detection of peripheral chronic pulmonary embolisms (CPE). 62 patients underwent a dual-energy chest CT angiographic examination with (a) reconstruction of diagnostic and perfusion images; (b) enabling depiction of vascular features of peripheral CPE on diagnostic images and perfusion defects (20 segments/patient; total: 1240 segments examined). The interpretation of diagnostic images was of two types: (a) standard (i.e., based on cross-sectional images alone) or (b) detailed (i.e., based on cross-sectional images and MIPs). The segment-based analysis showed (a) 1179 segments analyzable on both imaging modalities and 61 segments rated as nonanalyzable on perfusion images; (b) the percentage of diseased segments was increased by 7.2 % when perfusion imaging was compared to the detailed reading of diagnostic images, and by 26.6 % when compared to the standard reading of images. At a patient level, the extent of peripheral CPE was higher on perfusion imaging, with a greater impact when compared to the standard reading of diagnostic images (number of patients with a greater number of diseased segments: n = 45; 72.6 % of the study population). Perfusion imaging allows recognition of a greater extent of peripheral CPE compared to diagnostic imaging. • Dual-energy computed tomography generates standard diagnostic imaging and lung perfusion analysis. • Depiction of CPE on central arteries relies on standard diagnostic imaging. • Detection of peripheral CPE is improved by perfusion imaging.
NASA Astrophysics Data System (ADS)
Heydarian, Mohammadreza; Kirby, Miranda; Wheatley, Andrew; Fenster, Aaron; Parraga, Grace
2012-03-01
A semi-automated method for generating hyperpolarized helium-3 (3He) measurements of individual slice (2D) or whole lung (3D) gas distribution was developed. 3He MRI functional images were segmented using two-dimensional (2D) and three-dimensional (3D) hierarchical K-means clustering of the 3He MRI signal and in addition a seeded region-growing algorithm was employed for segmentation of the 1H MRI thoracic cavity volume. 3He MRI pulmonary function measurements were generated following two-dimensional landmark-based non-rigid registration of the 3He and 1H pulmonary images. We applied this method to MRI of healthy subjects and subjects with chronic obstructive lung disease (COPD). The results of hierarchical K-means 2D and 3D segmentation were compared to an expert observer's manual segmentation results using linear regression, Pearson correlations and the Dice similarity coefficient. 2D hierarchical K-means segmentation of ventilation volume (VV) and ventilation defect volume (VDV) was strongly and significantly correlated with manual measurements (VV: r=0.98, p<.0001 VDV: r=0.97, p<.0001) and mean Dice coefficients were greater than 92% for all subjects. 3D hierarchical K-means segmentation of VV and VDV was also strongly and significantly correlated with manual measurements (VV: r=0.98, p<.0001 VDV: r=0.64, p<.0001) and the mean Dice coefficients were greater than 91% for all subjects. Both 2D and 3D semi-automated segmentation of 3He MRI gas distribution provides a way to generate novel pulmonary function measurements.
Characteristics of Urban Sidewalks/Streets and Objectively Measured Physical Activity
Heinrich, Katie M.; Poston, Walker S.C.; Hyder, Melissa; Pyle, Sara
2007-01-01
Several studies have found significant relationships between environmental characteristics (e.g., number of destinations, aesthetics) and physical activity. While a few of these studies verified that the physical activities assessed were performed in the environments examined, none have done this in an urban, neighborhood setting. This information will help efforts to inform policy decisions regarding the design of more “physically active” communities. Fourteen environmental characteristics of 60, 305-m-long segments, located in an urban, residential setting, were directly measured using standardized procedures. The number of individuals walking, jogging, and biking in the segments was assessed using an observation technique. The segments were heterogeneous with regards to several of the environmental characteristics. A total of 473 individuals were seen walking, bicycling, or jogging in the segments during 3,600 min of observation (60 min/segment). Of the 473 seen, 315 were walking, 116 bicycling, and 42 jogging. A greater number of individuals were seen walking in segments with more traffic, sidewalk defects, graffiti, and litter and less desirable property aesthetics. Only one environmental characteristic was associated with bicycling and none were significantly related with jogging. This study provides further evidence that environmental characteristics and walking are related. It also adds new information regarding the importance of scale (e.g., micro, macro) and how some environmental characteristics of urban, residential sidewalks and streets relate to physical activity. PMID:18161026
Journal of Special Operations Medicine. Volume 10, Edition 2, Spring 2010
2010-01-01
national (LN) male carried to the firebase clinic by his family in severe pain with swelling of his left thigh following a motor- Fracture Detection...tient. (Image 1a) Once the patient’s pain was controlled, the 18D used CR for comparison and con- firmation. (Image 1b) Case 2: Distal Fibular...swollen left leg. The 18D used US to confirm a suspected fracture. (Image 4a) Once the pain was con- trolled the 18D confirmed the fractured tibia with CR
Isolated lateral collateral ligament complex injury in rock climbing and Brazilian Jiu-jitsu.
Davis, Bryan A; Hiller, Lucas P; Imbesi, Steven G; Chang, Eric Y
2015-08-01
We report two occurrences of high-grade tears of the lateral collateral ligament complex (LCLC), consisting of the anterolateral ligament (ALL) and fibular collateral ligament (FCL). One injury occurred in a rock climber and the other in a martial artist. Increasing awareness of isolated injuries of the LCLC will allow for appropriate diagnosis and management. We review and discuss the anatomy of the LCLC, the unique mechanism of isolated injury, as well as physical and imaging examination findings.
[Stereological analysis of rat bone tissue after a flight on the Kosmos-1129 biosatellite].
Prokhonchukov, A A; Peschanskiĭ, V S
1982-01-01
Stereological measurements of volume fractions of 53 samples of compact and spongy structures of bones of 15 rats were carried out. The measurements were performed on cortical lamellae, trabecules and lacunae, channels of osteons and matrices of femoral, tibial and fibular bones of rats. Postflight no significant changes were seen in the above parameters as compared to the vivarium controls. During readaptation to I g a slight increase in the volume fraction of spongy bones was noted.
Defect-Repairable Latent Feature Extraction of Driving Behavior via a Deep Sparse Autoencoder
Taniguchi, Tadahiro; Takenaka, Kazuhito; Bando, Takashi
2018-01-01
Data representing driving behavior, as measured by various sensors installed in a vehicle, are collected as multi-dimensional sensor time-series data. These data often include redundant information, e.g., both the speed of wheels and the engine speed represent the velocity of the vehicle. Redundant information can be expected to complicate the data analysis, e.g., more factors need to be analyzed; even varying the levels of redundancy can influence the results of the analysis. We assume that the measured multi-dimensional sensor time-series data of driving behavior are generated from low-dimensional data shared by the many types of one-dimensional data of which multi-dimensional time-series data are composed. Meanwhile, sensor time-series data may be defective because of sensor failure. Therefore, another important function is to reduce the negative effect of defective data when extracting low-dimensional time-series data. This study proposes a defect-repairable feature extraction method based on a deep sparse autoencoder (DSAE) to extract low-dimensional time-series data. In the experiments, we show that DSAE provides high-performance latent feature extraction for driving behavior, even for defective sensor time-series data. In addition, we show that the negative effect of defects on the driving behavior segmentation task could be reduced using the latent features extracted by DSAE. PMID:29462931
Li, Peng; Pashmforoush, Mohammad; Sucov, Henry M.
2011-01-01
Disruption of retinoic acid signaling causes a variety of pharyngeal arch artery and great vessel defects, as well as malformations in many other tissues, including those derived from the pharyngeal endoderm. Previous studies implied that arch artery defects in the context of defective RA signaling occur secondary to pharyngeal pouch segmentation defects, although this model has never been experimentally verified. In this study, we examined arch artery morphogenesis during mouse development, and the role of RA in this process. We show in normal embryos that the arch arteries form by vasculogenic differentiation of pharyngeal mesoderm. Using various genetic backgrounds and tissue-specific mutation approaches, we segregate pharyngeal arch artery and pharyngeal pouch defects in RA receptor mutants, and show that RA signal transduction only in pharyngeal mesoderm is required for arch artery formation. RA does not control pharyngeal mesodermal differentiation to endothelium, but instead promotes the aggregation of endothelial cells into nascent vessels. Expression of VE-cadherin was substantially reduced in RAR mutants, and this deficiency may underlie the arch artery defects. The consequences of disrupted mesodermal and endodermal RA signaling were restricted to the 4th and 6th arch arteries and to the 4th pharyngeal pouch, respectively, suggesting that different regulatory mechanisms control the formation of the more anterior arch arteries and pouches. PMID:22040871
Bilobed perforator free flaps for combined hemitongue and floor-of-the-mouth defects.
Longo, B; Ferri, G; Fiorillo, A; Rubino, C; Santanelli, F
2013-11-01
Combined hemiglossectomy and floor-of-the-mouth defects need accurate reconstructive planning to restore swallowing and speech function. The aim of this prospective study was to evaluate outcomes of the bilobed design applied to perforator free flaps for combined hemitongue and floor-of-the-mouth defects. Twelve patients with a mean age of 71 years (range, 60-84) addressed to combined hemiglossectomy and floor-of-the-mouth resection and bilobed-shaped perforator free-flap reconstruction were prospectively enrolled. Defects were classified as follows: type 1, including only the anterior mobile portion of the tongue (n = 3); type 2, involving both mobile tongue and tongue base (n = 6); and type 3, including segmental mandibulectomy combined with a type 1 or type 2 defect (n = 3). The Kruskal-Wallis and Bonferroni post hoc tests were used to compare outcomes. Type 1 defects were reconstructed by three anterolateral thigh (ALT) perforator flaps; type 2 defects were reconstructed by four ALT flaps and two vertical deep inferior epigastric perforator flaps; and type 3 defects were restored by three osteocutaneous fibula flaps. Eleven flaps (91.6%) healed uneventfully, while one (8.4%) suffered a small area of skin necrosis whose revision did not compromise functional results. Six patients achieved normal intelligible speech, five had acceptable intelligible speech and one had unintelligible speech (p = 0.356). Swallowing function was considered normal in eight patients and with mild impairment in four (p = 0.178). Cosmesis resulted excellent in seven patients and good in five (p = 0.855). The bilobed-shaped perforator free flaps were shown to be a safe and predictable solution for combined hemitongue and floor-of-the-mouth defects providing optimal aesthetic and functional outcomes. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
De Lorenzo, Andrea; Hachamovitch, Rory; Kang, Xingping; Gransar, Heidi; Sciammarella, Maria G; Hayes, Sean W; Friedman, John D; Cohen, Ishac; Germano, Guido; Berman, Daniel S
2005-01-01
The value of exercise-induced ST-segment depression for the prognostic evaluation of patients with 1 mm of ST depression or greater on the resting electrocardiogram is controversial. Patients who underwent exercise myocardial perfusion single photon emission computed tomography (MPS) and had resting ST depression of 1 mm or greater with a nondiagnostic exercise electrocardiographic response (n = 1122) were followed up for 3.4 +/- 2.3 years. Those with paced rhythm, pre-excitation, left bundle branch block, or myocardial revascularization within the first 60 days after MPS were excluded. Additional exercise-induced ST-segment depression was considered significant if > or = 2 mm MPS was scored semiquantitatively by use of a 20-segment model of the left ventricle; the percentage of myocardium involved with stress defects (% myo) was derived by normalizing to the maximal possible score of 80. Hard events were defined as nonfatal myocardial infarction or cardiac death. A Cox analysis was used to determine independent predictors of hard events among clinical, exercise, and nuclear variables. Hard event rates increased as a function of % myo for either patients with exercise-induced ST depression (1.4%/y for normal MPS vs 4.1%/y for % myo >10%, P < .03) or those without it (0.7%/y for normal MPS vs 3.0%/y for % myo >10%, P = .0001). Age, diabetes mellitus, shortness of breath as the presenting symptom, and % myo were independent predictors of hard events. Exercise-induced ST depression was predictive of hard events only when it was 3 mm or greater. The presence and extent of perfusion defects, reflected in the % myo, had incremental prognostic value over clinical variables and also over all degrees of exercise-induced ST depression. Although MPS effectively risk-stratifies patients with resting ST depression of 1 mm or greater, the prognostic value of exercise-induced ST depression is limited in these patients, with a small added risk when severe (> or = 3 mm).
Misonou, Kaori; Ishiai, Sumio; Seki, Keiko; Koyama, Yasumasa; Nakano, Naomi
2004-06-01
Twelve patients with left unilateral spatial neglect were examined with a newly devised "coloured line bisection task". They were presented with a horizontal line printed in blue on one side and in red on the other side; the proportions of the blue and red segments were varied. Immediately after placement of the subjective midpoint, the line was concealed and the patients were asked to name the colours of the right and left ends. Five patients who identified the left-end colour almost correctly had no visual field defect, while the other seven whose colour naming was impaired on the left side had left visual field defect. The rightward bisection errors were similarly distributed in the fair and poor colour-naming patients except for two patients from the latter group. The lesions of the fair colour-naming patients spared the lingual and fusiform gyri, which are known to be engaged in colour processing. Patients with neglect whose visual field is preserved may neglect the leftward extension of a line but not the colour in the neglected space. The poor colour-naming patients frequently failed to name the left-end colour that appeared to the left of their subjective midpoint, which indicates that they hardly searched leftward beyond that point. In such trials, they reported that the left end had the same colour as the right end. The results suggest that in patients with neglect and left visual field defect, both the leftward extent and the colour of a line may be represented on the basis of the information from the attended right segment.
Correction of the retinal dystrophy phenotype of the RCS rat by viral gene transfer of Mertk.
Vollrath, D; Feng, W; Duncan, J L; Yasumura, D; D'Cruz, P M; Chappelow, A; Matthes, M T; Kay, M A; LaVail, M M
2001-10-23
The Royal College of Surgeons (RCS) rat is a widely studied animal model of retinal degeneration in which the inability of the retinal pigment epithelium (RPE) to phagocytize shed photoreceptor outer segments leads to a progressive loss of rod and cone photoreceptors. We recently used positional cloning to demonstrate that the gene Mertk likely corresponds to the retinal dystrophy (rdy) locus of the RCS rat. In the present study, we sought to determine whether gene transfer of Mertk to a RCS rat retina would result in correction of the RPE phagocytosis defect and preservation of photoreceptors. We used subretinal injection of a recombinant replication-deficient adenovirus encoding rat Mertk to deliver the gene to the eyes of young RCS rats. Electrophysiological assessment of animals 30 days after injection revealed an increased sensitivity of treated eyes to low-intensity light. Histologic and ultrastructural assessment demonstrated substantial sparing of photoreceptors, preservation of outer segment structure, and correction of the RPE phagocytosis defect in areas surrounding the injection site. Our results provide definitive evidence that mutation of Mertk underlies the RCS retinal dystrophy phenotype, and that the phenotype can be corrected by treatment of juvenile animals. To our knowledge, this is the first demonstration of complementation of both a functional cellular defect (phagocytosis) and a photoreceptor degeneration by gene transfer to the RPE. These results, together with the recent discovery of MERTK mutations in individuals with retinitis pigmentosa, emphasize the importance of the RCS rat as a model for gene therapy of diseases that arise from RPE dysfunction.
Berman, Daniel S; Abidov, Aiden; Kang, Xingping; Hayes, Sean W; Friedman, John D; Sciammarella, Maria G; Cohen, Ishac; Gerlach, James; Waechter, Parker B; Germano, Guido; Hachamovitch, Rory
2004-01-01
Recently, a 17-segment model of the left ventricle has been recommended as an optimally weighted approach for interpreting myocardial perfusion single photon emission computed tomography (SPECT). Methods to convert databases from previous 20- to new 17-segment data and criteria for abnormality for the 17-segment scores are needed. Initially, for derivation of the conversion algorithm, 65 patients were studied (algorithm population) (pilot group, n = 28; validation group, n = 37). Three conversion algorithms were derived: algorithm 1, which used mid, distal, and apical scores; algorithm 2, which used distal and apical scores alone; and algorithm 3, which used maximal scores of the distal septal, lateral, and apical segments in the 20-segment model for 3 corresponding segments of the 17-segment model. The prognosis population comprised 16,020 consecutive patients (mean age, 65 +/- 12 years; 41% women) who had exercise or vasodilator stress technetium 99m sestamibi myocardial perfusion SPECT and were followed up for 2.1 +/- 0.8 years. In this population, 17-segment scores were derived from 20-segment scores by use of algorithm 2, which demonstrated the best agreement with expert 17-segment reading in the algorithm population. The prognostic value of the 20- and 17-segment scores was compared by converting the respective summed scores into percent myocardium abnormal. Conversion algorithm 2 was found to be highly concordant with expert visual analysis by the 17-segment model (r = 0.982; kappa = 0.866) in the algorithm population. In the prognosis population, 456 cardiac deaths occurred during follow-up. When the conversion algorithm was applied, extent and severity of perfusion defects were nearly identical by 20- and derived 17-segment scores. The receiver operating characteristic curve areas by 20- and 17-segment perfusion scores were identical for predicting cardiac death (both 0.77 +/- 0.02, P = not significant). The optimal prognostic cutoff value for either 20- or derived 17-segment models was confirmed to be 5% myocardium abnormal, corresponding to a summed stress score greater than 3. Of note, the 17-segment model demonstrated a trend toward fewer mildly abnormal scans and more normal and severely abnormal scans. An algorithm for conversion of 20-segment perfusion scores to 17-segment scores has been developed that is highly concordant with expert visual analysis by the 17-segment model and provides nearly identical prognostic information. This conversion model may provide a mechanism for comparison of studies analyzed by the 17-segment system with previous studies analyzed by the 20-segment approach.
An automated skin segmentation of Breasts in Dynamic Contrast-Enhanced Magnetic Resonance Imaging.
Lee, Chia-Yen; Chang, Tzu-Fang; Chang, Nai-Yun; Chang, Yeun-Chung
2018-04-18
Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is used to diagnose breast disease. Obtaining anatomical information from DCE-MRI requires the skin be manually removed so that blood vessels and tumors can be clearly observed by physicians and radiologists; this requires considerable manpower and time. We develop an automated skin segmentation algorithm where the surface skin is removed rapidly and correctly. The rough skin area is segmented by the active contour model, and analyzed in segments according to the continuity of the skin thickness for accuracy. Blood vessels and mammary glands are retained, which remedies the defect of removing some blood vessels in active contours. After three-dimensional imaging, the DCE-MRIs without the skin can be used to see internal anatomical information for clinical applications. The research showed the Dice's coefficients of the 3D reconstructed images using the proposed algorithm and the active contour model for removing skins are 93.2% and 61.4%, respectively. The time performance of segmenting skins automatically is about 165 times faster than manually. The texture information of the tumors position with/without the skin is compared by the paired t-test yielded all p < 0.05, which suggested the proposed algorithm may enhance observability of tumors at the significance level of 0.05.
Barigye, R; Davis, S; Hunt, R; Hunt, N; Walsh, S; Elliott, N; Burnup, C; Aumann, S; Day, C; Dyrting, K; Weir, R; Melville, L F
2016-10-01
This study assessed the neurotropism of bovine ephemeral fever (BEF) virus (BEFV) and described histomorphological abnormalities of the brain, spinal cord and peripheral nerves that may causally contribute to paresis or paralysis in BEF. Four paralysed and six asymptomatic but virus-infected cattle were monitored, and blood and serum samples screened by qRT-PCR, virus isolation and neutralisation tests. Fresh brain, spinal cord, peripheral nerve and other tissues were qRT-PCR-tested for viral RNA, while formalin-fixed specimens were processed routinely and immunohistochemically evaluated for histomorphological abnormalities and viral antigen distribution, respectively. The neurotropism of BEFV was immunohistochemically confirmed in the brain and peripheral nerves and peripheral neuropathy was demonstrated in three paralysed but not the six aneurological but virus-infected animals. Wallerian degeneration (WD) was present in the ventral funicular white matter of the lumbar spinal cord of a paralysed steer and in cervical and thoracic spinal cord segments of three paralysed animals. Although no spinal cord lesions were seen in the steer euthanased within 7 days of illness, peripheral neuropathy was present and more severe in nerves of the brachial plexuses than in the gluteal or fibular nerves. The only steer with WD in the lumbar spinal cord also showed intrahistiocytic cell viral antigen that was spatially distributed within areas of moderate brain stem encephalitis. The data confirmed neurotropism of BEFV in cattle and documented histomorphological abnormalities in peripheral nerves and brain which, together with spinal cord lesions, may contribute to chronic paralysis in BEFV-infected downer cattle. © 2016 Australian Veterinary Association.
Novel Therapy for Bone Regeneration in Large Segmental Defects
2015-10-01
mesenchymal stem cells (MSCs). The in- flammatory... mesenchymal stem cells and the wound healing process. Cells 2013;2:621-34. 17. Kumar A, Salimath BP, Stark GB, Finkenzeller G. 22 K.M. Davis et al.: Muscle...Gao X, Usas A, Tang Y, et al. A comparison of bone re- generation with human mesenchymal stem cells and mus- cle-derived stem cells and the
Novel Therapy for Bone Regeneration in Large Segmental Defects
2017-12-01
on fracture healing. Clin Orthop Relat Res. 1998;355(Suppl):S230–8. 37. Pape HC, Giannoudis PV. Fat embolism and IM nailing. Injury. 2006;37(Suppl 4...BMP), thrombopoietin (TPO), therapy, fracture healing, bone regeneration, minipig, pig 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT...2, TPO, or saline control. 2. KEYWORDS: Bone healing, bone morphogenetic protein (BMP), thrombopoietin (TPO), therapy, fracture healing, bone
Novel Therapy for Bone Regeneration in Large Segmental Defects
2016-10-01
reamed and nonreamed intrame- dullary nailing on fracture healing. Clin Orthop Relat Res. 1998;355(Suppl):S230–8. 37. Pape HC, Giannoudis PV. Fat embolism ...extension period (Year 4). 15. SUBJECT TERMS Bone healing, bone morphogenetic protein (BMP), thrombopoietin (TPO), therapy, fracture healing, bone...Bone healing, bone morphogenetic protein (BMP), thrombopoietin (TPO), therapy, fracture healing, bone regeneration, minipig, pig 3. OVERALL PROJECT
Rérolle, Camille; Saint-Martin, Pauline; Dedouit, Fabrice; Rousseau, Hervé; Telmon, Norbert
2013-09-10
The first step in the identification process of bone remains is to determine whether they are of human or nonhuman origin. This issue may arise when only a fragment of bone is available, as the species of origin is usually easily determined on a complete bone. The present study aims to assess the validity of a morphometric method used by French forensic anthropologists to determine the species of origin: the corticomedullary index (CMI), defined by the ratio of the diameter of the medullary cavity to the total diameter of the bone. We studied the constancy of the CMI from measurements made on computed tomography images (CT scans) of different human bones, and compared our measurements with reference values selected in the literature. The measurements obtained on CT scans at three different sites of 30 human femurs, 24 tibias, and 24 fibulas were compared between themselves and with the CMI reference values for humans, pigs, dogs and sheep. Our results differed significantly from these reference values, with three exceptions: the proximal quarter of the femur and mid-fibular measurements for the human CMI, and the proximal quarter of the tibia for the sheep CMI. Mid-tibial, mid-femoral, and mid-fibular measurements also differed significantly between themselves. Only 22.6% of CT scans of human bones were correctly identified as human. We concluded that the CMI is not an effective method for determining the human origin of bone remains. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Pigmentary glaucoma accompanied by Usher syndrome.
Koucheki, Behrooz; Jalali, Kamran Hodjat
2012-08-01
To report a case of pigmentary glaucoma (PG) accompanied by Usher syndrome. Case report. The results were presented after standard ocular examination, visual field test, anterior segment and fundus photography, electroretinography, and otolaryngology consultation were conducted. Typical retinitis pigmentosa, flat electroretinography, congenital sensorineural hearing loss, high intraocular pressure, Krukenberg spindle, iris concavity, radial iris transillumination defect, severe pigment deposition on the trabecular meshwork, and glaucomatous optic nerve damage were indicative of PG accompanied by Usher syndrome. In some rare cases, PG may coexist with Usher syndrome. Common findings of Usher syndrome, including night blindness, impaired vision, visual field defects, and retinal changes may distract the clinician from considering the diagnosis of glaucoma. Such association should be borne in mind to make a timely diagnosis and treatment possible.
Step Cut Lengthening: A Technique for Treatment of Flexor Pollicis Longus Tendon Rupture.
Chong, Chew-Wei; Chen, Shih-Heng
2018-04-01
Reconstruction of a tendon defect is a challenging task in hand surgery. Delayed repair of a ruptured flexor pollicis longus (FPL) tendon is often associated with tendon defect. Primary repair of the tendon is often not possible, particularly after debridement of the unhealthy segment of the tendon. As such, various surgical treatments have been described in the literature, including single-stage tendon grafting, 2-stage tendon grafting, flexor digitorum superficialis tendon transfer from ring finger, and interphalangeal joint arthrodesis. We describe step cut lengthening of FPL tendon for the reconstruction of FPL rupture. This is a single-stage reconstruction without the need for tendon grafting or tendon transfer. To our knowledge, no such technique has been previously described.
Sequential segmental classification of feline congenital heart disease.
Scansen, Brian A; Schneider, Matthias; Bonagura, John D
2015-12-01
Feline congenital heart disease is less commonly encountered in veterinary medicine than acquired feline heart diseases such as cardiomyopathy. Understanding the wide spectrum of congenital cardiovascular disease demands a familiarity with a variety of lesions, occurring both in isolation and in combination, along with an appreciation of complex nomenclature and variable classification schemes. This review begins with an overview of congenital heart disease in the cat, including proposed etiologies and prevalence, examination approaches, and principles of therapy. Specific congenital defects are presented and organized by a sequential segmental classification with respect to their morphologic lesions. Highlights of diagnosis, treatment options, and prognosis are offered. It is hoped that this review will provide a framework for approaching congenital heart disease in the cat, and more broadly in other animal species based on the sequential segmental approach, which represents an adaptation of the common methodology used in children and adults with congenital heart disease. Copyright © 2015 Elsevier B.V. All rights reserved.
Inohaya, Keiji; Takano, Yoshiro; Kudo, Akira
2010-06-01
The floor plate is a key organizer that controls the specification of neurons in the central nervous system. Here, we show a new role of the floor plate: segmental pattern formation of the vertebral column. Analysis of a spontaneous medaka mutant, fused centrum (fsc), which exhibits fused centra and the absence of the intervertebral ligaments, revealed that fsc encodes wnt4b, which was expressed exclusively in the floor plate. In fsc mutants, we found that wnt4b expression was completely lost in the floor plate and that abnormal conversion of the intervertebral ligament cells into osteoblasts appeared to cause a defect of the intervertebral ligaments. The establishment of the transgenic rescue lines and mosaic analyses allowed the conclusion to be drawn that production of wnt4b by floor plate cells is essential for the segmental patterning of the vertebral column. Our findings provide a novel perspective on the mechanism of vertebrate development.
Barbier, Dominique; De Billy, Benoît; Gicquel, Philippe; Bourelle, Sophie; Journeau, Pierre
2017-10-01
There are several options for reconstruction of proximal humerus resections after wide resection for malignant tumors in children. The clavicula pro humero technique is a biologic option that has been used in the past, but there are only scant case reports and small series that comment on the results of the procedure. Because the longevity of children mandates a reconstruction with potential longevity not likely to be achieved by other techniques, the clavicula pro humero technique may be a potential option in selected patients. (1) How successful is the clavicula pro humero procedure in achieving local tumor control? (2) What is the frequency of nonunion? (3) What are the complications of the procedure? (4) What scores do patients achieve (on the Musculoskeletal Tumor Society (MSTS) and the Toronto Extremity Salvage Score (TESS) after this procedure? Four university hospitals performed the clavicula pro humero technique in eight children aged 8 to 18 years between June 2006 and February 2014. During that period, general indications for this approach included all reconstructions of the proximal humerus for malignant tumors in children older than 8 years. All patients were followed for a mean of 40 months (range, 25-86 months); one patient was lost to followup before 2 years. The tumor resections removed the rotator cuff muscles in all patients, glenohumeral joint in five, and deltoid muscle in three. The median length of the bone defect after resection was 20 cm (range, 7-25 cm). It was reduced to 9 cm (range, 0-17 cm) or 27% (range, 0%-64%) of the total humerus length after clavicular rotation. Direct osteosynthesis (one patient), induced membrane technique (one patient), or vascularized fibular autograft (six patients) was used to complete the defect after rotation of the clavicle if necessary. Presence of union (defined as bone healing before 10 months, as assessed by disappearance of the osteotomy on AP and lateral view radiographs), and complications were determined by chart review performed by a surgeon not involved in patient care. Function assessed by the MSTS and the TESS scores were determined by the patients with their families. None of the patients had tumor recurrence. One patient died of pulmonary metastases before the 2-year followup. Proximal and distal bone unions were achieved before 10 months without an additional surgical procedure in two and six of seven patients, respectively. Fourteen local complications occurred resulting in nine revision operations. The main complication was aseptic proximal pseudarthrosis (five patients); other complications included one proximal junction fracture, one clavicle fracture complicated by clavicle osteolysis, one distal junction fracture, one necrosis of the skin paddle of the fibular autograft, one glenoclavicular ossification, and one distal pseudarthrosis complicated by a fracture of this distal junction. Function, as assessed by the MSTS score, was a median of 23 of 30 (range, 11-27). The median TESS score was 82% (range, 75%-92%). Shoulder ROM (median; range) in abduction, front elevation, and external and internal rotations were 70°(30°-90°), 75°(30°-85°), 10°(0°-20°), and 80°(80°-100°), respectively. Three of the seven patients reported dissatisfaction with the cosmetic appearance. The clavicula pro humero technique achieved oncologic local control after resection and reconstruction of proximal humerus tumors in children. Although union times are approximately 2 years and some patients underwent augmentation with other grafts, it eventually provides a solid, painless, biologic, and stable reconstruction and creates a mobile acromioclavicular joint and generally good function. Nonunion of the proximal junction is the main complication of this technique. We cannot directly compare this technique with other reconstruction options, and longer followup is needed, but this may be a useful reconstruction option to consider in select pediatric patients with sarcomas of the proximal humerus. Level IV, therapeutic study.
Finite element approximation of the fields of bulk and interfacial line defects
NASA Astrophysics Data System (ADS)
Zhang, Chiqun; Acharya, Amit; Puri, Saurabh
2018-05-01
A generalized disclination (g.disclination) theory (Acharya and Fressengeas, 2015) has been recently introduced that goes beyond treating standard translational and rotational Volterra defects in a continuously distributed defects approach; it is capable of treating the kinematics and dynamics of terminating lines of elastic strain and rotation discontinuities. In this work, a numerical method is developed to solve for the stress and distortion fields of g.disclination systems. Problems of small and finite deformation theory are considered. The fields of a single disclination, a single dislocation treated as a disclination dipole, a tilt grain boundary, a misfitting grain boundary with disconnections, a through twin boundary, a terminating twin boundary, a through grain boundary, a star disclination/penta-twin, a disclination loop (with twist and wedge segments), and a plate, a lenticular, and a needle inclusion are approximated. It is demonstrated that while the far-field topological identity of a dislocation of appropriate strength and a disclination-dipole plus a slip dislocation comprising a disconnection are the same, the latter microstructure is energetically favorable. This underscores the complementary importance of all of topology, geometry, and energetics in understanding defect mechanics. It is established that finite element approximations of fields of interfacial and bulk line defects can be achieved in a systematic and routine manner, thus contributing to the study of intricate defect microstructures in the scientific understanding and predictive design of materials. Our work also represents one systematic way of studying the interaction of (g.)disclinations and dislocations as topological defects, a subject of considerable subtlety and conceptual importance (Aharoni et al., 2017; Mermin, 1979).
Raisutis, Renaldas; Samaitis, Vykintas
2017-01-01
This work proposes a novel hybrid signal processing technique to extract information on disbond-type defects from a single B-scan in the process of non-destructive testing (NDT) of glass fiber reinforced plastic (GFRP) material using ultrasonic guided waves (GW). The selected GFRP sample has been a segment of wind turbine blade, which possessed an aerodynamic shape. Two disbond type defects having diameters of 15 mm and 25 mm were artificially constructed on its trailing edge. The experiment has been performed using the low-frequency ultrasonic system developed at the Ultrasound Institute of Kaunas University of Technology and only one side of the sample was accessed. A special configuration of the transmitting and receiving transducers fixed on a movable panel with a separation distance of 50 mm was proposed for recording the ultrasonic guided wave signals at each one-millimeter step along the scanning distance up to 500 mm. Finally, the hybrid signal processing technique comprising the valuable features of the three most promising signal processing techniques: cross-correlation, wavelet transform, and Hilbert–Huang transform has been applied to the received signals for the extraction of defects information from a single B-scan image. The wavelet transform and cross-correlation techniques have been combined in order to extract the approximated size and location of the defects and measurements of time delays. Thereafter, Hilbert–Huang transform has been applied to the wavelet transformed signal to compare the variation of instantaneous frequencies and instantaneous amplitudes of the defect-free and defective signals. PMID:29232845
Pascucci, Simone; Bassani, Cristiana; Palombo, Angelo; Poscolieri, Maurizio; Cavalli, Rosa
2008-02-22
This paper describes a fast procedure for evaluating asphalt pavement surface defects using airborne emissivity data. To develop this procedure, we used airborne multispectral emissivity data covering an urban test area close to Venice (Italy).For this study, we first identify and select the roads' asphalt pavements on Multispectral Infrared Visible Imaging Spectrometer (MIVIS) imagery using a segmentation procedure. Next, since in asphalt pavements the surface defects are strictly related to the decrease of oily components that cause an increase of the abundance of surfacing limestone, the diagnostic absorption emissivity peak at 11.2μm of the limestone was used for retrieving from MIVIS emissivity data the areas exhibiting defects on asphalt pavements surface.The results showed that MIVIS emissivity allows establishing a threshold that points out those asphalt road sites on which a check for a maintenance intervention is required. Therefore, this technique can supply local government authorities an efficient, rapid and repeatable road mapping procedure providing the location of the asphalt pavements to be checked.
Montanini, R; Freni, F; Rossi, G L
2012-09-01
This paper reports one of the first experimental results on the application of ultrasound activated lock-in vibrothermography for quantitative assessment of buried flaws in complex cast parts. The use of amplitude modulated ultrasonic heat generation allowed selective response of defective areas within the part, as the defect itself is turned into a local thermal wave emitter. Quantitative evaluation of hidden damages was accomplished by estimating independently both the area and the depth extension of the buried flaws, while x-ray 3D computed tomography was used as reference for sizing accuracy assessment. To retrieve flaw's area, a simple yet effective histogram-based phase image segmentation algorithm with automatic pixels classification has been developed. A clear correlation was found between the thermal (phase) signature measured by the infrared camera on the target surface and the actual mean cross-section area of the flaw. Due to the very fast cycle time (<30 s/part), the method could potentially be applied for 100% quality control of casting components.
Defect Facilitated Phonon Transport through Kinks in Boron Carbide Nanowires
Zhang, Qian; Cui, Zhiguang; Wei, Zhiyong; ...
2017-05-08
Nanowires of complex morphologies, such as kinked wires, have been recently synthesized and demonstrated for novel devices and applications. However, the effects of these morphologies on thermal transport have not been well studied. Through systematic experimental measurements, we show in this paper that single-crystalline, defect-free kinks in boron carbide nanowires can pose a thermal resistance up to ~30 times larger than that of a straight wire segment of equivalent length. Analysis suggests that this pronounced resistance can be attributed to the combined effects of backscattering of highly focused phonons and required mode conversion at the kink. Interestingly, it is alsomore » found that instead of posing resistance, structural defects in the kink can actually assist phonon transport through the kink and reduce its resistance. Finally, given the common kink-like wire morphology in nanoelectronic devices and required low thermal conductivity for thermoelectric devices, these findings have important implications in precise thermal management of electronic devices and thermoelectrics.« less
Defect Facilitated Phonon Transport through Kinks in Boron Carbide Nanowires
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Qian; Cui, Zhiguang; Wei, Zhiyong
Nanowires of complex morphologies, such as kinked wires, have been recently synthesized and demonstrated for novel devices and applications. However, the effects of these morphologies on thermal transport have not been well studied. Through systematic experimental measurements, we show in this paper that single-crystalline, defect-free kinks in boron carbide nanowires can pose a thermal resistance up to ~30 times larger than that of a straight wire segment of equivalent length. Analysis suggests that this pronounced resistance can be attributed to the combined effects of backscattering of highly focused phonons and required mode conversion at the kink. Interestingly, it is alsomore » found that instead of posing resistance, structural defects in the kink can actually assist phonon transport through the kink and reduce its resistance. Finally, given the common kink-like wire morphology in nanoelectronic devices and required low thermal conductivity for thermoelectric devices, these findings have important implications in precise thermal management of electronic devices and thermoelectrics.« less
DYF-1 Is Required for Assembly of the Axoneme in Tetrahymena thermophila▿ †
Dave, Drashti; Wloga, Dorota; Sharma, Neeraj; Gaertig, Jacek
2009-01-01
In most cilia, the axoneme can be subdivided into three segments: proximal (the transition zone), middle (with outer doublet microtubules), and distal (with singlet extensions of outer doublet microtubules). How the functionally distinct segments of the axoneme are assembled and maintained is not well understood. DYF-1 is a highly conserved ciliary protein containing tetratricopeptide repeats. In Caenorhabditis elegans, DYF-1 is specifically needed for assembly of the distal segment (G. Ou, O. E. Blacque, J. J. Snow, M. R. Leroux, and J. M. Scholey. Nature. 436:583-587, 2005). We show that Tetrahymena cells lacking an ortholog of DYF-1, Dyf1p, can assemble only extremely short axoneme remnants that have structural defects of diverse natures, including the absence of central pair and outer doublet microtubules and incomplete or absent B tubules on the outer microtubules. Thus, in Tetrahymena, DYF-1 is needed for either assembly or stability of the entire axoneme. Our observations support the conserved function for DYF-1 in axoneme assembly or stability but also show that the consequences of loss of DYF-1 for axoneme segments are organism specific. PMID:19581442
NASA Astrophysics Data System (ADS)
Cronin, John
This thesis explores the effects of missing ballast on track behavior and degradation. As ballast is an integral part of the track structure, the hypothesized effect of missing ballast is that defects will be more common which in turn leads to more derailments. In order to quantify the volume of missing ballast, remote sensing technologies were used to provide an accurate profile of the ballast. When the existing profile is compared to an idealized profile, the area of missing ballast can be computed. The area is then subdivided into zones which represent the area in which the ballast performs a key function in the track structure. These areas are then extrapolated into the volume of missing ballast for each zone based on the distance between collected profiles. In order to emphasize the key functions that the zones previously created perform, weighting factors were developed based on common risk-increasing hazards, such as curves and heavy axle loads, which are commonly found on railways. These weighting factors are applied to the specified zones' missing ballast volume when such a hazard exists in that segment of track. Another set of weighting factors were developed to represent the increased risk, or preference for lower risk, for operational factors such as the transport of hazardous materials or for being a key route. Through these weighting factors, ballast replenishment can be prioritized to focus on the areas that pose a higher risk of derailments and their associated costs. For the special cases where the risk or aversion to risk comes from what is being transported, such as the case with hazardous materials or passengers, an economic risk assessment was completed in order to quantify the risk associated with their transport. This economic risk assessment looks at the increased costs associated with incidents that occur and how they compare to incidents which do not directly involve the special cargos. In order to provide support for the use of the previously developed weightings as well as to quantify the actual impact that missing ballast has on the rate of geometry defects, analyses which quantified the risk of missing ballast were performed. In addition to quantifying the rate of defects, analyses were performed which looked at the impact associated with curved track, how the location of missing ballast impacts the rate of geometry defects and how the combination of the two compared with the previous analyses. Through this research, the relationship between the volume of missing ballast and ballast-related defects has been identified and quantified. This relationship is positive for the aggregate of all ballast-related defects but does not always exist for individual defects which occasionally have unique behavior. For the non-ballast defects, a relationship between missing ballast and their rate of occurrence did not always appear to exist. The impact of curves was apparent, showing that the rate of defects was either similar to or exceeded the rate of defects for tangent track. For the analyses which looked at the location of ballast in crib or shoulder, the results were quite similar to the previous analyses. The development, application and improvements of a risk-based ballast maintenance prioritization system provides a relatively low-cost and effective method to improve the operational safety for all railroads.
Allogeneic adipose-derived stem cells regenerate bone in a critical-sized ulna segmental defect
Wen, Congji; Yan, Hai; Fu, Shibo; Qian, Yunliang
2016-01-01
Adipose-derived stem cells (ASCs) with multilineage potential can be induced into osteoblasts, adipocytes and chondrocytes. ASCs as seed cell are widely used in the field of tissue engineering, but most studies either use autologous cells as the source or an immunodeficient animal as the host. In our present study, we explored the feasibility of applying allogeneic ASCs and demineralized bone matrix (DBM) scaffolds for repairing tubular bone defects without using immunosuppressive therapy. Allogeneic ASCs were expanded and seeded on DBM scaffolds and induced to differentiate along the osteogenic lineage. Eight Sprague–Dawley (SD) rats were used in this study and bilateral critical-sized defects (8 mm) of the ulna were created and divided into two groups: with ASC-DBM constructs or DBM alone. The systemic immune response and the extent of bone healing were evaluated post-operatively. Twenty-four weeks after implantation, digital radiography (DR) testing showed that new bones had formed in the experimental group. By contrast, no bone tissue formation was observed in the control group. This study demonstrated that allogeneic ASCs could promote bone regeneration and repair tubular bone defects combined with DBM by histologically typical bone without systemic immune response PMID:25819682
Automatic detection system of shaft part surface defect based on machine vision
NASA Astrophysics Data System (ADS)
Jiang, Lixing; Sun, Kuoyuan; Zhao, Fulai; Hao, Xiangyang
2015-05-01
Surface physical damage detection is an important part of the shaft parts quality inspection and the traditional detecting methods are mostly human eye identification which has many disadvantages such as low efficiency, bad reliability. In order to improve the automation level of the quality detection of shaft parts and establish its relevant industry quality standard, a machine vision inspection system connected with MCU was designed to realize the surface detection of shaft parts. The system adopt the monochrome line-scan digital camera and use the dark-field and forward illumination technology to acquire images with high contrast; the images were segmented to Bi-value images through maximum between-cluster variance method after image filtering and image enhancing algorithms; then the mainly contours were extracted based on the evaluation criterion of the aspect ratio and the area; then calculate the coordinates of the centre of gravity of defects area, namely locating point coordinates; At last, location of the defects area were marked by the coding pen communicated with MCU. Experiment show that no defect was omitted and false alarm error rate was lower than 5%, which showed that the designed system met the demand of shaft part on-line real-time detection.
Nayak, D P; Tobita, K; Janda, J M; Davis, A R; De, B K
1978-01-01
A temperature-sensitive group II mutant of influenza virus, ts-52, with a presumed defect in viral RNA synthesis, readily produced von Magnus-type defective interfering virus (DI virus) when passed serially (four times) at high multiplicity in MDBK cells. The defective virus (ts-52 DI virus) had a high hemagglutinin and a low infectivity titer, and strongly interfered with the replication of standard infectious viruses (both ts-52 and wild-type ts+) in co-infected cells. Progeny virus particles produced by co-infection of DI virus and infectious virus were also defective and also had low infectivity, high hemagglutinating activity, and a strong interfering property. Infectious viruses ts+ and ts-52 were indistinguishable from ts-52 DI viruses by sucrose velocity or density gradient analysis. Additionally, these viruses all possessed similar morphology. However, when the RNA of DI viruses was analyzed by use of polyacrylamide gels containing 6 M urea, there was a reduction in the amount of large RNA species (V1 to V4), and a number of new smaller RNA species (D1 to D6) with molecular weights ranging from 2.9 X 10(5) to 1.05 X 10(5) appeared. Since these smaller RNA species (D1 to D6) were absent in some clones of infectious viruses, but were consistently associated with DI viruses and increased during undiluted passages and during co-infection of ts-52 with DI virus, they appeared to be a characteristic of DI viruses. Additionally, the UV target size of interfering activity and infectivity of DI virus indicated that interfering activity was 40 times more resistant to UV irradiation than was infectivity, further implicating small RNA molecules in interference. Our data suggest that the loss of infectivity observed among DI viruses may be due to nonspecific loss of a viral RNA segment(s), and the interfering property of DI viruses may be due to interfering RNA segments (DIRNA, D1 to D6). ts-52 DI virus interfered with the replication of standard virus (ts+) at both permissive (34 degrees C) and nonpermissive temperatures. The infectivity of the progeny virus was reduced to 0.2% for ts+ and 0.05% for ts-52 virus without a reduction in hemagglutinin titer. Interference was dependent on the concentration of DI virus. A particle ratio of 1 between DI virus (0.001 PFU/cell) and infectious virus (1.0 PFU/cell) produced a maximal amount of interference. Infectious virus yield was reduced 99.9% without any reduction of the yield of DI viruses Interference was also dependent on the time of addition of DI virus. Interference was most effective within the first 3 h of infection by infectious virus, indicating interference with an early function during viral replication. Images PMID:702654
Jungmann, P.M.; Kraus, M.S.; Nardo, L.; Liebl, H.; Alizai, H.; Joseph, G.B.; Liu, F.; Lynch, J.; McCulloch, C.E.; Nevitt, M.C.; Link, T.M.
2014-01-01
Purpose To study the natural evolution of cartilage T2 relaxation times in knees with various extents of morphological cartilage abnormalities, assessed with 3T MRI from the Osteoarthritis Initiative. Materials and Methods Right knee MRIs of 245, 45–60 year old individuals without radiographic OA were included. Cartilage was segmented and T2 maps were generated in five compartments (patella, medial and lateral femoral condyle, medial and lateral tibia) at baseline and two-year follow-up. We examined the association of T2 values and two-year change of T2 values with various Whole-Organ MR Imaging Scores (WORMS). Statistical analysis was performed with ANOVA and Students t-tests. Results Higher baseline T2 was associated with more severe cartilage defects at baseline and subsequent cartilage loss (P<0.001). However, longitudinal T2 change was inversely associated with both baseline (P=0.038) and follow-up (P=0.002) severity of cartilage defects. Knees that developed new cartilage defects had smaller increases in T2 than subjects without defects (P=0.045). Individuals with higher baseline T2 showed smaller T2 increases over time (P<0.001). Conclusion An inverse correlation of longitudinal T2 changes versus baseline T2 values and morphological cartilage abnormalities suggests that once morphological cartilage defects occur, T2 values may be limited for evaluating further cartilage degradation. PMID:24038491
Repair of diaphyseal bone defects with calcitriol-loaded PLGA scaffolds and marrow stromal cells.
Yoon, Sun Jung; Park, Ki Suk; Kim, Moon Suk; Rhee, John M; Khang, Gilson; Lee, Hai Bang
2007-05-01
Calcitriol (1,25(OH)2D3)-loaded porous poly(D,L-lactide-co-glycolide) (PLGA) scaffolds prepared by solvent casting/salt leaching method were used to repair a 1.5 cm diaphyseal segmental bone defect as a fully absorbable osteogenic biomaterial. The in vitro release of sulforhodamine B (SRB) from PLGA scaffold was measured using spectrophotometer, considering SRB as a model drug. The SRB released from SRB-incorporated PLGA scaffold during 3 months was with relatively low initial burst. The calcitriol-loaded PLGA scaffolds with or without marrow stromal cells (MSCs) were implanted in a critical-sized intercalated bone defect in rabbit femur. Defects were assessed by radiographs until 9 weeks. The bony union of the defect was observed only in the calcitriol-loaded groups. RT-PCR results indicated that MSCs, which were seeded into calcitriol-loaded scaffold, expressed an increased level of alkaline phosphatase, osteonectin, and type I collagen mRNA at day 10. After 2 and 4 weeks, the implanted scaffolds were evaluated by histology. New osteoid matrix and direct calcium deposits were more evident in calcitriol/PLGA/MSC group. Three-dimensional computed tomography and frontal tomographic images of repaired femur showed that normal femur anatomy had been restored with cortical bone with no implanted PLGA remnants at 20 weeks. It can be concluded that the porous calcitriol-loaded PLGA scaffold combined with MSCs may be a novel method for repairing the large loaded bone defect.
Rapid and reliable healing of critical size bone defects with genetically modified sheep muscle.
Liu, F; Ferreira, E; Porter, R M; Glatt, V; Schinhan, M; Shen, Z; Randolph, M A; Kirker-Head, C A; Wehling, C; Vrahas, M S; Evans, C H; Wells, J W
2015-09-21
Large segmental defects in bone fail to heal and remain a clinical problem. Muscle is highly osteogenic, and preliminary data suggest that autologous muscle tissue expressing bone morphogenetic protein-2 (BMP-2) efficiently heals critical size defects in rats. Translation into possible human clinical trials requires, inter alia, demonstration of efficacy in a large animal, such as the sheep. Scale-up is fraught with numerous biological, anatomical, mechanical and structural variables, which cannot be addressed systematically because of cost and other practical issues. For this reason, we developed a translational model enabling us to isolate the biological question of whether sheep muscle, transduced with adenovirus expressing BMP-2, could heal critical size defects in vivo. Initial experiments in athymic rats noted strong healing in only about one-third of animals because of unexpected immune responses to sheep antigens. For this reason, subsequent experiments were performed with Fischer rats under transient immunosuppression. Such experiments confirmed remarkably rapid and reliable healing of the defects in all rats, with bridging by 2 weeks and remodelling as early as 3-4 weeks, despite BMP-2 production only in nanogram quantities and persisting for only 1-3 weeks. By 8 weeks the healed defects contained well-organised new bone with advanced neo-cortication and abundant marrow. Bone mineral content and mechanical strength were close to normal values. These data demonstrate the utility of this model when adapting this technology for bone healing in sheep, as a prelude to human clinical trials.
Infrared machine vision system for the automatic detection of olive fruit quality.
Guzmán, Elena; Baeten, Vincent; Pierna, Juan Antonio Fernández; García-Mesa, José A
2013-11-15
External quality is an important factor in the extraction of olive oil and the marketing of olive fruits. The appearance and presence of external damage are factors that influence the quality of the oil extracted and the perception of consumers, determining the level of acceptance prior to purchase in the case of table olives. The aim of this paper is to report on artificial vision techniques developed for the online estimation of olive quality and to assess the effectiveness of these techniques in evaluating quality based on detecting external defects. This method of classifying olives according to the presence of defects is based on an infrared (IR) vision system. Images of defects were acquired using a digital monochrome camera with band-pass filters on near-infrared (NIR). The original images were processed using segmentation algorithms, edge detection and pixel value intensity to classify the whole fruit. The detection of the defect involved a pixel classification procedure based on nonparametric models of the healthy and defective areas of olives. Classification tests were performed on olives to assess the effectiveness of the proposed method. This research showed that the IR vision system is a useful technology for the automatic assessment of olives that has the potential for use in offline inspection and for online sorting for defects and the presence of surface damage, easily distinguishing those that do not meet minimum quality requirements. Crown Copyright © 2013 Published by Elsevier B.V. All rights reserved.
Mei, Shuang; Wang, Yudan; Wen, Guojun
2018-04-02
Fabric defect detection is a necessary and essential step of quality control in the textile manufacturing industry. Traditional fabric inspections are usually performed by manual visual methods, which are low in efficiency and poor in precision for long-term industrial applications. In this paper, we propose an unsupervised learning-based automated approach to detect and localize fabric defects without any manual intervention. This approach is used to reconstruct image patches with a convolutional denoising autoencoder network at multiple Gaussian pyramid levels and to synthesize detection results from the corresponding resolution channels. The reconstruction residual of each image patch is used as the indicator for direct pixel-wise prediction. By segmenting and synthesizing the reconstruction residual map at each resolution level, the final inspection result can be generated. This newly developed method has several prominent advantages for fabric defect detection. First, it can be trained with only a small amount of defect-free samples. This is especially important for situations in which collecting large amounts of defective samples is difficult and impracticable. Second, owing to the multi-modal integration strategy, it is relatively more robust and accurate compared to general inspection methods (the results at each resolution level can be viewed as a modality). Third, according to our results, it can address multiple types of textile fabrics, from simple to more complex. Experimental results demonstrate that the proposed model is robust and yields good overall performance with high precision and acceptable recall rates.
Development of a Novel Segmental Bone Defect Construct
2017-10-01
differentiation, and biological activity of both primary synoviocytes and bone marrow derived connective tissue progenitor cells. During the majority of...halted activity on the project from the dates of 31 May 2016 to 13 July 2017. However, the project is on schedule with the current, revised project...supervised all project activities and participated in the preparation of the manuscript that was produced during this reporting period. Name: Dr
Novel Therapy for Bone Regeneration in Large Segmental Defects
2014-10-01
for post-operative animal care. The time, effort, and even drugs required ( pain management) for post-operative management of minipigs has been...substantially larger than was anticipated. The veterinarian is still finalizing the post-operative pain management protocol as with each surgery he is...assessment/management. By Monday morning the veterinarian usually reduces the pain scoring and pain medications to twice a day. This of course does
Novel Therapy for Bone Regeneration in Large Segmental Defects
2016-10-01
Giannoudis PV. Fat embolism and IM nailing. Injury. 2006;37(Suppl 4):S1–2. 38. Wenda K, Ritter G, Degreif J, Rudigier J. Pathogenesis of pul- monary... fracture healing, bone regeneration, minipig, pig 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES 19a. NAME OF...saline control. 2. KEYWORDS: Bone healing, bone morphogenetic protein (BMP), thrombopoietin (TPO), therapy, fracture healing, bone regeneration, minipig
Ready to Use Tissue Construct for Military Bone & Cartilage Trauma
2014-10-01
during nail introduction and reaming. In the present study, we examined the load - bearing capacity and optimal internal fixation of a bone/poly-ε...segmental defect, (a) axial loading via ball bearing , (b) torsional loading via square clamp allowing axial displacement, (c) three-point bending of tibia...knee joints by simulating loads seen during ambulation and knee range of motion. Our central hypothesis is that an anatomically and
Characterization of Electrically Active Defects in Si Using CCD Image Sensors
1978-02-01
63 35 Dislocation Segments in CCD Imager . . . . . . . . . . . . . 64 36 422 Reflection Topograph of Dislocation Loop ir... Loops . . . . . 3 39 422 Reflection Topograph of Scratch on CCD Imager, . . . 69 40 Dark Current Display of a CCD Imager with 32 ms integration Time...made of each slice using the elon -asoorbio aold developer described in Appendix D. The inagers were then thinned using the procedure at Appendix taor
A hybrid intelligence approach to artifact recognition in digital publishing
NASA Astrophysics Data System (ADS)
Vega-Riveros, J. Fernando; Santos Villalobos, Hector J.
2006-02-01
The system presented integrates rule-based and case-based reasoning for artifact recognition in Digital Publishing. In Variable Data Printing (VDP) human proofing could result prohibitive since a job could contain millions of different instances that may contain two types of artifacts: 1) evident defects, like a text overflow or overlapping 2) style-dependent artifacts, subtle defects that show as inconsistencies with regard to the original job design. We designed a Knowledge-Based Artifact Recognition tool for document segmentation, layout understanding, artifact detection, and document design quality assessment. Document evaluation is constrained by reference to one instance of the VDP job proofed by a human expert against the remaining instances. Fundamental rules of document design are used in the rule-based component for document segmentation and layout understanding. Ambiguities in the design principles not covered by the rule-based system are analyzed by case-based reasoning, using the Nearest Neighbor Algorithm, where features from previous jobs are used to detect artifacts and inconsistencies within the document layout. We used a subset of XSL-FO and assembled a set of 44 document samples. The system detected all the job layout changes, while obtaining an overall average accuracy of 84.56%, with the highest accuracy of 92.82%, for overlapping and the lowest, 66.7%, for the lack-of-white-space.
Ravitch, Mark M.
1958-01-01
Hirschsprung's disease is marked by constipation from the time of birth, with the development, if uncorrected, of a protuberant abdomen and flared costal margins. The rectal ampulla is empty and the abdomen is filled with fecal masses. Pain is not prominent. Flatus is passed in large amounts. Encopresis does not occur. Barium enema shows the characteristic narrowed distal rectal segment and biopsy of the rectum shows absence of the ganglion cells of the myenteric plexus. Treatment is operative resection of the distal narrow segment and a primary anastomosis. Hirschsprung's disease may be mimicked in children with: 1. Psychogenic constipation—pseudo-Hirschsprung's disease. Unlike Hirschsprung's disease, symptoms do not appear at birth, encopresis is common, and the barium enema shows no narrow distal segment. 2. Mental retardation and cerebral defect. 3. Corrected imperforate anus—on the basis of stenosis, imperfect innervation or poor habit training. 4. Cretinism—with severe constipation and intestinal dilatation perhaps the presenting symptoms. Treatment of these four groups of children with severe constipation not due to Hirschsprung's disease is: For Group 1, open discussion with parent and child. Assumption by the physician of full control of the details of treatment, and relegation of parent to the role of the physician's agent in following the prescribed regimen. For Group 2, an enema regimen. Whereas fairly rapid restoration (and then persistence) of normal bowel habit can be expected in Group 1, the basic defects in Group 2 may require indefinite continuation of treatment. For Group 3, regular enema regimen, in the less severe cases—one identical with that used in Group 1, and dilatation of strictures or anoplasty. In Group 4, thyroid hormone therapy relieves the constipation of hypothyroidism and causes reversion of radiographic changes in the colon and rectum. PMID:13561108
Bloom DNA Helicase Facilitates Homologous Recombination between Diverged Homologous Sequences*
Kikuchi, Koji; Abdel-Aziz, H. Ismail; Taniguchi, Yoshihito; Yamazoe, Mitsuyoshi; Takeda, Shunichi; Hirota, Kouji
2009-01-01
Bloom syndrome caused by inactivation of the Bloom DNA helicase (Blm) is characterized by increases in the level of sister chromatid exchange, homologous recombination (HR) associated with cross-over. It is therefore believed that Blm works as an anti-recombinase. Meanwhile, in Drosophila, DmBlm is required specifically to promote the synthesis-dependent strand anneal (SDSA), a type of HR not associating with cross-over. However, conservation of Blm function in SDSA through higher eukaryotes has been a matter of debate. Here, we demonstrate the function of Blm in SDSA type HR in chicken DT40 B lymphocyte line, where Ig gene conversion diversifies the immunoglobulin V gene through intragenic HR between diverged homologous segments. This reaction is initiated by the activation-induced cytidine deaminase enzyme-mediated uracil formation at the V gene, which in turn converts into abasic site, presumably leading to a single strand gap. Ig gene conversion frequency was drastically reduced in BLM−/− cells. In addition, BLM−/− cells used limited donor segments harboring higher identity compared with other segments in Ig gene conversion event, suggesting that Blm can promote HR between diverged sequences. To further understand the role of Blm in HR between diverged homologous sequences, we measured the frequency of gene targeting induced by an I-SceI-endonuclease-mediated double-strand break. BLM−/− cells showed a severer defect in the gene targeting frequency as the number of heterologous sequences increased at the double-strand break site. Conversely, the overexpression of Blm, even an ATPase-defective mutant, strongly stimulated gene targeting. In summary, Blm promotes HR between diverged sequences through a novel ATPase-independent mechanism. PMID:19661064
Saini, Sangeeta; Bagchi, Biman
2010-07-21
Recent single molecule experiments have suggested the existence of a photochemical funnel in the photophysics of conjugated polymers, like poly[2-methoxy-5-(2'-ethylhexyl)oxy-1,4-phenylenevinylene] (MEH-PPV). The funnel is believed to be a consequence of the presence of conformational or chemical defects along the polymer chain and efficient non-radiative energy transfer among different chromophore segments. Here we address the effect of the excitation energy dynamics on the photophysics of PPV. The PPV chain is modeled as a polymer with the length distribution of chromophores given either by a Gaussian or by a Poisson distribution. We observe that the Poisson distribution of the segment lengths explains the photophysics of PPV better than the Gaussian distribution. A recently proposed version of an extended 'particle-in-a-box' model is used to calculate the exciton energies and the transition dipole moments of the chromophores, and a master equation to describe the excitation energy transfer among different chromophores. The rate of energy transfer is assumed to be given here, as a first approximation, by the well-known Förster expression. The observed excitation population dynamics confirms the photochemical funneling of excitation energy from shorter to longer chromophores of the polymer chain. The time scale of spectral shift and energy transfer for our model polymer, with realistic values of optical parameters, is in the range of 200-300 ps. We find that the excitation energy may not always migrate towards the longest chromophore segments in the polymer chain as the efficiency of energy transfer between chromophores depends on the separation distance between the two and their relative orientation.
Holcomb, Valerie B; von Lindern, Marieke; Jong, Willeke M. C; Zeeuw, Chris I. De; Suh, Yousin; Hasty, Paul; Hoeijmakers, Jan H. J; van der Horst, Gijsbertus T. J; Mitchell, James R
2006-01-01
How congenital defects causing genome instability can result in the pleiotropic symptoms reminiscent of aging but in a segmental and accelerated fashion remains largely unknown. Most segmental progerias are associated with accelerated fibroblast senescence, suggesting that cellular senescence is a likely contributing mechanism. Contrary to expectations, neither accelerated senescence nor acute oxidative stress hypersensitivity was detected in primary fibroblast or erythroblast cultures from multiple progeroid mouse models for defects in the nucleotide excision DNA repair pathway, which share premature aging features including postnatal growth retardation, cerebellar ataxia, and death before weaning. Instead, we report a prominent phenotypic overlap with long-lived dwarfism and calorie restriction during postnatal development (2 wk of age), including reduced size, reduced body temperature, hypoglycemia, and perturbation of the growth hormone/insulin-like growth factor 1 neuroendocrine axis. These symptoms were also present at 2 wk of age in a novel progeroid nucleotide excision repair-deficient mouse model (XPDG602D/R722W/XPA−/−) that survived weaning with high penetrance. However, despite persistent cachectic dwarfism, blood glucose and serum insulin-like growth factor 1 levels returned to normal by 10 wk, with hypoglycemia reappearing near premature death at 5 mo of age. These data strongly suggest changes in energy metabolism as part of an adaptive response during the stressful period of postnatal growth. Interestingly, a similar perturbation of the postnatal growth axis was not detected in another progeroid mouse model, the double-strand DNA break repair deficient Ku80 −/− mouse. Specific (but not all) types of genome instability may thus engage a conserved response to stress that evolved to cope with environmental pressures such as food shortage. PMID:17173483
van de Ven, Marieke; Andressoo, Jaan-Olle; Holcomb, Valerie B; von Lindern, Marieke; Jong, Willeke M C; De Zeeuw, Chris I; Suh, Yousin; Hasty, Paul; Hoeijmakers, Jan H J; van der Horst, Gijsbertus T J; Mitchell, James R
2006-12-15
How congenital defects causing genome instability can result in the pleiotropic symptoms reminiscent of aging but in a segmental and accelerated fashion remains largely unknown. Most segmental progerias are associated with accelerated fibroblast senescence, suggesting that cellular senescence is a likely contributing mechanism. Contrary to expectations, neither accelerated senescence nor acute oxidative stress hypersensitivity was detected in primary fibroblast or erythroblast cultures from multiple progeroid mouse models for defects in the nucleotide excision DNA repair pathway, which share premature aging features including postnatal growth retardation, cerebellar ataxia, and death before weaning. Instead, we report a prominent phenotypic overlap with long-lived dwarfism and calorie restriction during postnatal development (2 wk of age), including reduced size, reduced body temperature, hypoglycemia, and perturbation of the growth hormone/insulin-like growth factor 1 neuroendocrine axis. These symptoms were also present at 2 wk of age in a novel progeroid nucleotide excision repair-deficient mouse model (XPD(G602D/R722W)/XPA(-/-)) that survived weaning with high penetrance. However, despite persistent cachectic dwarfism, blood glucose and serum insulin-like growth factor 1 levels returned to normal by 10 wk, with hypoglycemia reappearing near premature death at 5 mo of age. These data strongly suggest changes in energy metabolism as part of an adaptive response during the stressful period of postnatal growth. Interestingly, a similar perturbation of the postnatal growth axis was not detected in another progeroid mouse model, the double-strand DNA break repair deficient Ku80(-/-) mouse. Specific (but not all) types of genome instability may thus engage a conserved response to stress that evolved to cope with environmental pressures such as food shortage.