Bender, David A.; Zogorski, John S.; Mueller, David K.; Rose, Donna L.; Martin, Jeffrey D.; Brenner, Cassandra K.
2011-01-01
This report describes the quality of volatile organic compound (VOC) data collected from October 1996 to December 2008 from groundwater and surface-water sites for the U.S. Geological Survey's National Water-Quality Assessment (NAWQA) Program. The VOC data described were collected for three NAWQA site types: (1) domestic and public-supply wells, (2) monitoring wells, and (3) surface-water sites. Contamination bias, based on the 90-percent upper confidence limit (UCL) for the 90th percentile of concentrations in field blanks, was determined for VOC samples from the three site types. A way to express this bias is that there is 90-percent confidence that this amount of contamination would be exceeded in no more than 10 percent of all samples (including environmental samples) that were collected, processed, shipped, and analyzed in the same manner as the blank samples. This report also describes how important native water rinsing may be in decreasing carryover contamination, which could be affecting field blanks. The VOCs can be classified into four contamination categories on the basis of the 90-percent upper confidence limit (90-percent UCL) concentration distribution in field blanks. Contamination category 1 includes compounds that were not detected in any field blanks. Contamination category 2 includes VOCs that have a 90-percent UCL concentration distribution in field blanks that is about an order of magnitude lower than the concentration distribution of the environmental samples. Contamination category 3 includes VOCs that have a 90-percent UCL concentration distribution in field blanks that is within an order of magnitude of the distribution in environmental samples. Contamination category 4 includes VOCs that have a 90-percent UCL concentration distribution in field blanks that is at least an order of magnitude larger than the concentration distribution of the environmental samples. Fifty-four of the 87 VOCs analyzed in samples from domestic and public-supply wells were not detected in field blanks (contamination category 1), and 33 VOC were detected in field blanks. Ten of the 33 VOCs had a 90-percent UCL concentration distribution in field blanks that was at least an order of magnitude lower than the concentration distribution in environmental samples (contamination category 2). These 10 VOCs may have had some contamination bias associated with the environmental samples, but the potential contamination bias was negligible in comparison to the environmental data; therefore, the field blanks were assumed to be representative of the sources of contamination bias affecting the environmental samples for these 10 VOCs. Seven VOCs had a 90-percent UCL concentration distribution of the field blanks that was within an order of magnitude of the concentration distribution of the environmental samples (contamination category 3). Sixteen VOCs had a 90-percent UCL concentration distribution in the field blanks that was at least an order of magnitude greater than the concentration distribution of the environmental samples (contamination category 4). Field blanks for these 16 VOCs appear to be nonrepresentative of the sources of contamination bias affecting the environmental samples because of the larger concentration distributions (and sometimes higher frequency of detection) in field blanks than in environmental samples. Forty-three of the 87 VOCs analyzed in samples from monitoring wells were not detected in field blanks (contamination category 1), and 44 VOCs were detected in field blanks. Eight of the 44 VOCs had a 90-percent UCL concentration distribution in field blanks that was at least an order of magnitude lower than concentrations in environmental samples (contamination category 2). These eight VOCs may have had some contamination bias associated with the environmental samples, but the potential contamination bias was negligible in comparison to the environmental data; therefore, the field blanks were assumed to be representative. Seven VOCs had a 90-percent UCL concentration distribution in field blanks that was of the same order of magnitude as the concentration distribution of the environmental samples (contamination category 3). Twenty-nine VOCs had a 90-percent UCL concentration distribution in the field blanks that was an order of magnitude greater than the distribution of the environmental samples (contamination category 4). Field blanks for these 29 VOCs appear to be nonrepresentative of the sources of contamination bias to the environmental samples. Fifty-four of the 87 VOCs analyzed in surface-water samples were not detected in field blanks (category 1), and 33 VOC were detected in field blanks. Sixteen of the 33 VOCs had a 90-percent UCL concentration distribution in field blanks that was at least an order of magnitude lower than the concentration distribution in environmental samples (contamination category 2). These 16 VOCs may have had some contamination bias associated with the environmental samples, but the potential contamination bias was negligible in comparison to the environmental data; therefore, the field blanks were assumed to be representative. Ten VOCs had a 90-percent UCL concentration distribution in field blanks that was similar to the concentration distribution of environmental samples (contamination category 3). Seven VOCs had a 90-percent UCL concentration distribution in the field blanks that was greater than the concentration distribution in environmental samples (contamination category 4). Field-blank samples for these seven VOCs appear to be nonrepresentative of the sources of contamination bias to the environmental samples. The relation between the detection of a compound in field blanks and the detection in subsequent environmental samples appears to be minimal. The median minimum percent effectiveness of native water rinsing is about 79 percent for the 19 VOCs detected in more than 5 percent of field blanks from all three site types. The minimum percent effectiveness of native water rinsing (10 percent) was for toluene in surface-water samples, likely because of the large detection frequency of toluene in surface-water samples (about 79 percent) and in the associated field-blank samples (46.5 percent). The VOCs that were not detected in field blanks (contamination category 1) from the three site types can be considered free of contamination bias, and various interpretations for environmental samples, such as VOC detection frequency at multiple assessment levels and comparisons of concentrations to benchmarks, are not limited for these VOCs. A censoring level for making comparisons at different assessment levels among environmental samples could be applied to concentrations of 9 VOCs in samples from domestic and public-supply wells, 16 VOCs in samples from monitoring wells, and 9 VOCs in surface-water samples to account for potential low-level contamination bias associated with these selected VOCs. Bracketing the potential contamination by comparing the detection and concentration statistics with no censoring applied to the potential for contamination bias on the basis of the 90-percent UCL for the 90th-percentile concentrations in field blanks may be useful when comparisons to benchmarks are done in a study. The VOCs that were not detected in field blanks (contamination category 1) from the three site types can be considered free of contamination bias, and various interpretations for environmental samples, such as VOC detection frequency at multiple assessment levels and comparisons of concentrations to benchmarks, are not limited for these VOCs. A censoring level for making comparisons at different assessment levels among environmental samples could be applied to concentrations of 9 VOCs in samples from domestic and public-supply wells, 16 VOCs in samples from monitoring wells, and 9 VOCs in surface-water samples to account for potential low-level contamination bias associated with these selected VOCs. Bracketing the potential contamination by comparing the detection and concentration statistics with no censoring applied to the potential for contamination bias on the basis of the 90-percent UCL for the 90th-percentile concentrations in field blanks may be useful when comparisons to benchmarks are done in a study.
Thiros, Susan A.; Bender, David A.; Mueller, David K.; Rose, Donna L.; Olsen, Lisa D.; Martin, Jeffrey D.; Bernard, Bruce; Zogorski, John S.
2011-01-01
The Field Contamination Study (FCS) was designed to determine the field processes that tend to result in clean field blanks and to identify potential sources of contamination to blanks collected in the field from selected volatile organic compounds (VOCs) and wastewater-indicator compounds (WICs). The VOCs and WICs analyzed in the FCS were detected in blanks collected by the U.S. Geological Survey (USGS) National Water-Quality Assessment (NAWQA) Program during 1996–2008 and 2002–08, respectively. To minimize the number of variables, the study required ordering of supplies just before sampling, storage of supplies and equipment in clean areas, and use of adequate amounts of purge-and-trap volatile-grade methanol and volatile pesticide-grade blank water (VPBW) to clean sampling equipment and to collect field blanks.Blanks and groundwater samples were collected during 2008–09 at 16 sites, which were a mix of water-supply and monitoring wells, located in 9 States. Five different sample types were collected for the FCS at each site: (1) a source-solution blank collected at the USGS National Water Quality Laboratory (NWQL) using laboratory-purged VPBW, (2) source-solution blanks collected in the field using laboratory-purged VPBW, (3) source-solution blanks collected in the field using field-purged VPBW, (4) a field blank collected using field-purged VPBW, and (5) a groundwater sample collected from a well. The source-solution blank and field-blank analyses were used to identify, quantify, and document extrinsic contamination and to help determine the sources and causes of data-quality problems that can affect groundwater samples.Concentrations of compounds detected in FCS analyses were quantified and results were stored in the USGS National Water Information System database after meeting rigorous identification and quantification criteria. The study also utilized information provided by laboratory analysts about evidence indicating the presence of selected compounds, using less rigorous identification criteria than is required for reporting data to the National Water Information System database. For the FCS, these data are considered adequate to indicate "evidence of presence," and were used only for diagnostic purposes. Evidence of VOCs and WICs at low concentrations near or less than the long-term method detection level can indicate a contamination problem that could affect future datasets if method detection levels were ever to be lowered.
Fram, Miranda S.; Olsen, Lisa D.; Belitz, Kenneth
2012-01-01
Volatile organic compounds (VOCs) were analyzed in quality-control samples collected for the California Groundwater Ambient Monitoring and Assessment (GAMA) Program Priority Basin Project. From May 2004 through September 2010, a total of 2,026 groundwater samples, 211 field blanks, and 109 source-solution blanks were collected and analyzed for concentrations of 85 VOCs. Results from analyses of these field and source-solution blanks and of 2,411 laboratory instrument blanks during the same time period were used to assess the quality of data for the 2,026 groundwater samples. Eighteen VOCs were detected in field blanks or source-solution blanks: acetone, benzene, bromodichloromethane, 2-butanone, carbon disulfide, chloroform, 1,1-dichloroethene, dichloromethane, ethylbenzene, tetrachloroethene, styrene, tetrahydrofuran, toluene, trichloroethene, trichlorofluoromethane, 1,2,4-trimethylbenzene, m- and p-xylenes, and o-xylene. The objective of the evaluation of the VOC-blank data was to determine if study reporting levels (SRLs) were needed for any of the VOCs detected in blanks to ensure the quality of the data from groundwater samples. An SRL is equivalent to a raised reporting level that is used in place of the reporting level used by the analyzing laboratory [long‑term method detection level (LT-MDL) or laboratory reporting level (LRL)] to reduce the probability of reporting false-positive detections. Evaluation of VOC-blank data was done in three stages: (1) identification of a set of representative quality‑control field blanks (QCFBs) to be used for calculation of SRLs and identification of VOCs amenable to the SRL approach, (2) evaluation of potential sources of contamination to blanks and groundwater samples by VOCs detected in field blanks, and (3) selection of appropriate SRLs from among four potential SRLs for VOCs detected in field blanks and application of those SRLs to the groundwater data. An important conclusion from this study is that to ensure the quality of the data from groundwater samples, it was necessary to apply different methods of determining SRLs from field blank data to different VOCs, rather than use the same method for all VOCs. Four potential SRL values were defined by using three approaches: two values were defined by using a binomial probability method based on one-sided, nonparametric upper confidence limits, one was defined as equal to the maximum concentration detected in the field blanks, and one was defined as equal to the maximum laboratory method detection level used during the period when samples were collected for the project. The differences in detection frequencies and concentrations among different types of blanks (laboratory instrument blanks, source-solution blanks, and field blanks collected with three different sampling equipment configurations) and groundwater samples were used to infer the sources and mechanisms of contamination for each VOC detection in field blanks. Other chemical data for the groundwater samples (oxidation-reduction state, co-occurrence of VOCs, groundwater age) and ancillary information about the well sites (land use, presence of known sources of contamination) were used to evaluate whether the patterns of detections of VOCs in groundwater samples before and after application of potential SRLs were plausible. On this basis, the appropriate SRL was selected for each VOC that was determined to require an SRL. The SRLs for ethylbenzene [0.06 microgram per liter (μg/L)], m- and p-xylenes (0.33 μg/L), o-xylene (0.12 μg/L), toluene (0.69 μg/L), and 1,2,4-trimethylbenzene (0.56 μg/L) corresponded to the highest concentrations detected in the QCFBs and were selected because they resulted in the most censoring of groundwater data. Comparisons of hydrocarbon ratios in groundwater samples and blanks and comparisons between detection frequencies of the five hydrocarbons in groundwater samples and different types of blanks suggested three dominant sources of contamination that affected groundwater samples and blanks: (1) ethylbenzene, m- and p-xylenes, o-xylene, and toluene from fuel or exhaust components sorbed onto sampling lines, (2) toluene from vials and the source blank water, and (3) 1,2,4-trimethylbenzene from materials used for collection of samples for radon-222 analysis.
NASA Astrophysics Data System (ADS)
Huang, Suilou; Rahn, Kenneth A.; Arimoto, Richard
During the Atmosphere/Ocean Chemistry Experiment (AEROCE), field blanks of certain elements in aerosol samples occasionally increased abruptly, always during periods of unusually high atmospheric concentrations. We hypothesized that the anomalous blanks were created by coarse aerosol entering the sampling shelters and depositing onto the blank filters. If so, samples taken nearby should have been similarly affected. To test this hypothesis, we developed a simple graphical method in which elemental masses in field blanks are plotted against elemental masses in pumped samples, and zones of proportionality between the two are sought. Data from Bermuda and Mace Head (coastal western Ireland) confirmed that depositional zones did indeed appear, but only for coarse-particle elements and only under certain conditions. Actual increases of crustal and pollution-derived elements agreed well with values predicted from settling velocities and sampling rates: blanks increased up to an order of magnitude or more but samples by less than 1%. Marine elements behaved like crustal elements in most samples but occasionally were much more enriched: blanks increased up to 30-fold and samples up to about 3%. It thus appears that when coarse-particle elements are present in high concentrations, their field blanks and samples may be measurably affected by dry deposition. Depending on the elements of interest, this dry deposition may have to be measured and the concentrations corrected.
Olsen, Lisa D.; Fram, Miranda S.; Belitz, Kenneth
2010-01-01
Trace-element quality-control samples (for example, source-solution blanks, field blanks, and field replicates) were collected as part of a statewide investigation of groundwater quality in California, known as the Priority Basins Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basins Project is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB) to assess and monitor the quality of groundwater resources used for drinking-water supply and to improve public knowledge of groundwater quality in California. Trace-element field blanks were collected to evaluate potential bias in the corresponding environmental data. Bias in the environmental data could result from contamination in the field during sample collection, from the groundwater coming into contact with contaminants on equipment surfaces or from other sources, or from processing, shipping, or analyzing the samples. Bias affects the interpretation of environmental data, particularly if any constituents are present solely as a result of extrinsic contamination that would have otherwise been absent from the groundwater that was sampled. Field blanks were collected, analyzed, and reviewed to identify and quantify extrinsic contamination bias. Data derived from source-solution blanks and laboratory quality-control samples also were considered in evaluating potential contamination bias. Eighty-six field-blank samples collected from May 2004 to January 2008 were analyzed for the concentrations of 25 trace elements. Results from these field blanks were used to interpret the data for the 816 samples of untreated groundwater collected over the same period. Constituents analyzed were aluminum (Al), antimony (Sb), arsenic (As), barium (Ba), beryllium (Be), boron (B), cadmium (Cd), chromium (Cr), cobalt (Co), copper (Cu), iron (Fe), lead (Pb), lithium (Li), manganese (Mn), mercury (Hg), molybdenum (Mo), nickel (Ni), selenium (Se), silver (Ag), strontium (Sr), thallium (Tl), tungsten (W), uranium (U), vanadium (V), and zinc (Zn). The detection frequency and the 90th percentile concentration at greater than 90 percent confidence were determined from the field-blank data for each trace element, and these results were compared to each constituent's long-term method detection level (LT-MDL) to determine whether a study reporting level (SRL) was necessary to ensure that no more than 10 percent of the detections in groundwater samples could be attributed solely to contamination bias. Only two of the trace elements analyzed, Li and Se, had zero detections in the 86 field blanks. Ten other trace elements (Sb, As, Be, B, Cd, Co, Mo, Ag, Tl, and U) were detected in fewer than 5 percent of the field blanks. The field-blank results for these constituents did not necessitate establishing SRLs. Of the 13 constituents that were detected in more than 5 percent of the field blanks, six (Al, Ba, Cr, Mn, Hg, and V) had field-blank results that indicated a need for SRLs that were at or below the highest laboratory reporting levels (LRL) used during the sampling period; these SRLs were needed for concentrations between the LT-MDLs and LRLs. The other seven constituents with detection frequencies above 5 percent (Cu, Fe, Pb, Ni, Sr, W, and Zn) had field-blank results that necessitated SRLs greater than the highest LRLs used during the study period. SRLs for these seven constituents, each set at the 90th percentile of their concentrations in the field blanks, were at least an order of magnitude below the regulatory thresholds established for drinking water for health or aesthetic purposes; therefore, reporting values below the SRLs as less than or equal to (=) the measured value would not prevent the identification of values greater than the drinking-water thresholds. The SRLs and drinking-water thresholds, respectively, for these 7 trace elements are Cu (1.7 ?g/L and 1,300
Martin, Jeffrey D.; Gilliom, Robert J.; Schertz, Terry L.
1999-01-01
Field blanks did show evidence of contamination by some pesticides. Most of the pesticides detected in field blanks, however, were detected more frequently and at higher concentrations in environmental water samples. Two criteria were used to evaluate the need to consider contamination in water-quality assessments: (1) a ratio of the frequency of pesticide detection in environmental water samples to the frequency of detection in field blanks of 5.0 or less and (2) a ratio of the median concentration detected in environmental water samples to the maximum concentration detected in field blanks of 2.0 or less. These criteria indicate that contamination, for the majority of the pesticide data collected for the NAWQA Program, probably does not need to be considered in the analysis and interpretation of (1) the frequency of pesticide detection or (2) the median concentration of pesticides detected. Contamination must be considered, however, in detection frequency for cispermethrin, pronamide, p,p' -DDE, pebulate, propargite, ethalfluralin, and triallate in surface water and fenuron, benfluralin, pronamide, cis-permethrin, triallate, chlorpyrifos, trifluralin, propanil, p,p' -DDE, bromacil, dacthal, diazinon, and diuron in ground water. Contamination also must be considered in median concentrations detected for pronamide, p,p' -DDE, propargite, napropamide, and triallate in surface water and benfluralin, cis-permethrin, triallate, chlorpyrifos, trifluralin, p,p' -DDE, dacthal, and diazinon in ground water.
Davis, Tracy A.; Olsen, Lisa D.; Fram, Miranda S.; Belitz, Kenneth
2014-01-01
Groundwater samples have been collected in California as part of statewide investigations of groundwater quality conducted by the U.S. Geological Survey for the Groundwater Ambient Monitoring and Assessment (GAMA) Priority Basin Project (PBP). The GAMA-PBP is being conducted in cooperation with the California State Water Resources Control Board to assess and monitor the quality of groundwater resources used for drinking-water supply and to improve public knowledge of groundwater quality in California. Quality-control samples (source-solution blanks, equipment blanks, and field blanks) were collected in order to ensure the quality of the groundwater sample results. Olsen and others (2010) previously determined study reporting levels (SRLs) for trace-element results based primarily on field blanks collected in California from May 2004 through January 2008. SRLs are raised reporting levels used to reduce the likelihood of reporting false detections attributable to contamination bias. The purpose of this report is to identify any changes in the frequency and concentrations of detections in field blanks since the last evaluation and update the SRLs for more recent data accordingly. Constituents analyzed were aluminum (Al), antimony (Sb), arsenic (As), barium (Ba), beryllium (Be), boron (B), cadmium (Cd), chromium (Cr), cobalt (Co), copper (Cu), iron (Fe), lead (Pb), lithium (Li), manganese (Mn), molybdenum (Mo), nickel (Ni), selenium (Se), silver (Ag), strontium (Sr), thallium (Tl), tungsten (W), uranium (U), vanadium (V), and zinc (Zn). Data from 179 field blanks and equipment blanks collected from March 2006 through March 2013 by the GAMA-PBP indicated that for trace elements that had a change in detection frequency and concentration since the previous review, the shift occurred near October 2009, in conjunction with a change in the capsule filters used by the study. Results for 89 field blanks and equipment blanks collected from October 2009 through March 2013 were evaluated for potential contamination bias by using the same approach developed by Olsen and others (2010). Some data collected by the National Water-Quality Assessment (NAWQA) Program for the Southern California Coastal Drainages study unit were included to supplement the GAMA-PBP data. The detection frequency and upper threshold of potential contamination bias (BD-90/90) were determined from field-blank and equipment-blank data for each trace element. The BD-90/90 is the 90th percentile concentration of potential extrinsic contamination calculated by using the binomial probability distribution for greater than 90 percent confidence. Additionally, data from laboratory blanks and blind blanks analyzed by the National Water Quality Laboratory (NWQL) during water years 2010 through 2013, and compiled by the USGS Branch of Quality Systems (BQS), were considered for each trace element. These results were compared to each constituent’s reporting level to determine whether an SRL was necessary to minimize the potential for detections in the groundwater samples, attributed principally to contamination bias. Results of the evaluation were used to set SRLs for trace-element data for about 1,135 samples of groundwater collected by the GAMA-PBP between October 2009 and March 2013. Ten trace elements analyzed (Sb, As, Be, B, Cd, Li, Se, Ag, Tl, and U) had blank results that did not necessitate establishing SRLs during this review or the review by Olsen and others (2010). Five trace elements analyzed (Al, Ba, Cr, Sr, and V) had blank results that necessitated establishing an SRL during the previous review but did not need an SRL starting October 2009. One trace element (Fe) had field and laboratory-blank results that necessitated keeping the previous SRL (6 micrograms per liter [μg/L]). Two trace elements (Ni and W) had quality-control results that warranted decreasing the previous SRL, and five trace elements (Cu, Pb, Mn, Mo, and Zn) had field, laboratory, or blind blank results that warranted establishing an SRL for the first time or increasing the previous SRL. SRLs for Cu (2.1 μg/L), Pb (0.82 μg/L), Mn (0.66 μg/L), Mo (0.023 μg/L), Ni (0.21 μg/L), W (0.023 μg/L), and Zn (6.2 μg/L) were changed to these levels starting October 2009, based on the BD-90/90 concentration for field blanks or the 99th percentile concentration for laboratory or blind blanks. The SRL for Fe was maintained at 6 μg/L, based on the minimum laboratory reporting level for iron. SRLs for these eight constituents were at least an order of magnitude below the regulatory benchmarks established for drinking water for health and aesthetic purposes; therefore, the practice of reporting concentrations below the SRLs as less than or equal to (≤) the measured value would not prevent the identification of values greater than the drinking-water benchmarks. Co was detected in 99 percent of field blanks, and with a BD-90/90 concentration of 0.38 μg/L, all groundwater results starting October 2009 were coded as “reviewed and rejected.” Co does not currently have a regulatory benchmark for drinking water. The primary sources of contamination for trace elements inferred from this review are the equipment or processes used in the field to collect the samples or in the laboratory. In particular, contamination in field blanks of Co and Mn was attributed to the high-capacity 0.45-micrometer pore-size capsule filters that were in regular use beginning in October 2009 by several USGS programs, including the GAMA-PBP and NAWQA Program, for filtering samples for analysis of trace elements. The SRLs determined in this report are intended to be used for GAMA groundwater-quality data for samples collected October 2009 through March 2013, or for as long as quality-control data indicate contamination similar to what was observed in this report; quality-control data should be continuously reviewed and SRLs re-assessed on at least a study-unit basis.
Seeing Red and Shooting Blanks: A Study of Red Quasars and Blank Field X-Ray Sources
NASA Technical Reports Server (NTRS)
Oliversen, Ronald J. (Technical Monitor); Elvis, Martin
2004-01-01
One type of "Blank Field X-ray Source" is now being seen in deep Chandra and XMM-Newton surveys. These are the newly dubbed "XBONGs" (X-ray Bright, Optically Normal Galaxies). The study of the brighter counterparts from ROSAT and XMM- Newton serendipitous surveys is therefore of renewed interest and topicality. We continue to define the properties of the ROSAT sample which is the basis of this grant. We expect to publish the SEDs of these sources soon.
This data set contains the method performance results. This includes field blanks, method blanks, duplicate samples, analytical duplicates, matrix spikes, and surrogate recovery standards.
The Children’s Total Exposure to Persistent Pesticides and Other Persistent Pollutant (...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, L.M.; Bartholomay, R.C.; Campbell, L.J.
1998-10-01
The U.S. Geological (USGS) and the Idaho Department of Water Resources, in cooperation with the U.S. Department of Energy, collected and analyzed water samples to monitor the water quality of the Snake River Plain aquifer from the southern boundary of the Idaho National Engineering and Environmental Laboratory to the Hagerman area, Idaho. Concurrently, replicate samples and blank samples were collected and analyzed as part of the quality-assurance/quality-control program. Samples were analyzed from inorganic constituents, gross radioactivity and radionuclides, organic constituents, and stable isotopes. To evaluate the precision of field and laboratory methods, analytical results of the water-quality and replicate samplesmore » were compared statistically for equivalence on the basis of the precision associated with each result. Statistical comparisons of the data indicated that 95 percent of the results of the replicate pairs were equivalent. Blank-sample analytical results indicated th at the inorganic blank water and volatile organic compound blank water from the USGS National Water Quality Laboratory and the distilled water from the Idaho Department of Water Resources were suitable for blanks; blank water from other sources was not. Equipment-blank analytical results were evaluated to determine if a bias had been introduced and possible sources of bias. Most equipment blanks were analyzed for trace elements and volatile organic compounds; chloroform was found in one equipment blank. Two of the equipment blanks were prepared after collection and analyses of the water-quality samples to determine whether contamination had been introduced during the sampling process. Results of one blank indicated that a hose used to divert water away from pumps and electrical equipment had contaminated the samples with some volatile organic compounds. Results of the other equipment blank, from the apparatus used to filter dissolved organic carbon samples, indicated that the filtering apparatus did not affect water-quality samples.« less
This data set contains the method performance results for CTEPP-OH. This includes field blanks, method blanks, duplicate samples, analytical duplicates, matrix spikes, and surrogate recovery standards.
The Children’s Total Exposure to Persistent Pesticides and Other Persisten...
Munday, Cathy; Domagalski, Joseph L.
2003-01-01
Evaluating the extent that bias and variability affect the interpretation of ground- and surface-water data is necessary to meet the objectives of the National Water-Quality Assessment (NAWQA) Program. Quality-control samples used to evaluate the bias and variability include annual equipment blanks, field blanks, field matrix spikes, surrogates, and replicates. This report contains quality-control results for the constituents critical to the ground- and surface-water components of the Sacramento River Basin study unit of the NAWQA Program. A critical constituent is one that was detected frequently (more than 50 percent of the time in blank samples), was detected at amounts exceeding water-quality standards or goals, or was important for the interpretation of water-quality data. Quality-control samples were collected along with ground- and surface-water samples during the high intensity phase (cycle 1) of the Sacramento River Basin NAWQA beginning early in 1996 and ending in 1998. Ground-water field blanks indicated contamination of varying levels of significance when compared with concentrations detected in environmental ground-water samples for ammonia, dissolved organic carbon, aluminum, and copper. Concentrations of aluminum in surface-water field blanks were significant when compared with environmental samples. Field blank samples collected for pesticide and volatile organic compound analyses revealed no contamination in either ground- or surface-water samples that would effect the interpretation of environmental data, with the possible exception of the volatile organic compound trichloromethane (chloroform) in ground water. Replicate samples for ground water and surface water indicate that variability resulting from sample collection, processing, and analysis was generally low. Some of the larger maximum relative percentage differences calculated for replicate samples occurred between samples having lowest absolute concentration differences and(or) values near the reporting limit. Surrogate recoveries for pesticides analyzed by gas chromatography/mass spectrometry (GC/MS), pesticides analyzed by high performance liquid chromatography (HPLC), and volatile organic compounds in ground- and surface-water samples were within the acceptable limits of 70 to 130 percent and median recovery values between 82 and 113 percent. The recovery percentages for surrogate compounds analyzed by HPLC had the highest standard deviation, 20 percent for ground-water samples and 16 percent for surface-water samples, and the lowest median values, 82 percent for ground-water samples and 91 percent for surface-water samples. Results were consistent with the recovery results described for the analytical methods. Field matrix spike recoveries for pesticide compounds analyzed using GC/MS in ground- and surface-water samples were comparable with published recovery data. Recoveries of carbofuran, a critical constituent in ground- and surface-water studies, and desethyl atrazine, a critical constituent in the ground-water study, could not be calculated because of problems with the analytical method. Recoveries of pesticides analyzed using HPLC in ground- and surface-water samples were generally low and comparable with published recovery data. Other methodological problems for HPLC analytes included nondetection of the spike compounds and estimated values of spike concentrations. Recovery of field matrix spikes for volatile organic compounds generally were within the acceptable range, 70 and 130 percent for both ground- and surface-water samples, and median recoveries from 62 to 127 percent. High or low recoveries could be related to errors in the field, such as double spiking or using spike solution past its expiration date, rather than problems during analysis. The methodological changes in the field spike protocol during the course of the Sacramento River Basin study, which included decreasing the amount of spike solu
Bartholomay, Roy C.; Knobel, LeRoy L.; Tucker, Betty J.; Twining, Brian V.
2000-01-01
The U.S. Geological Survey, in response to a request from the U.S. Department of Energy?s Phtsburgh Naval Reactors Ofilce, Idaho Branch Office, sampled water from 13 wells during 1997?98 as part of a long-term project to monitor water quality of the Snake River Plain aquifer in the vicinity of the Naval Reactors Facility, Idaho National Engineering and Environmental Laboratory, Idaho. Water samples were analyzed for naturally occurring constituents and man-made contaminants. A totalof91 samples were collected from the 13 monitoring wells. The routine samples contained detectable concentrations of total cations and dissolved anions, and nitrite plus nitrate as nitrogen. Most of the samples also had detectable concentrations of gross alpha- and gross beta-particle radioactivity and tritium. Fourteen qualityassurance samples also were collected and analyze~ seven were field-blank samples, and seven were replicate samples. Most of the field blank samples contained less than detectable concentrations of target constituents; however, some blank samples did contain detectable concentrations of calcium, magnesium, barium, copper, manganese, nickel, zinc, nitrite plus nitrate, total organic halogens, tritium, and selected volatile organic compounds.
NHEXAS PHASE I ARIZONA STUDY--QA ANALYTICAL RESULTS FOR PESTICIDE METABOLITES IN BLANK SAMPLES
The Pesticide Metabolites in Blank Samples data set contains the analytical results of measurements of up to 4 pesticide metabolites in 3 blank samples from 3 households. Measurements were made in blank samples of urine. Blank samples were used to assess the potential for sampl...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holdren, M.W.; Smith, D.L.; Russell, N.K.
1988-06-01
The objective of the study was to investigate the use of 2,4-dinitrophenylhydrazine (DNPH) impregnated adsorbents for sampling airborne aldehydes. Experimental results using a 17 cu m environmental chamber and various spiked amounts of aldehyde material (low ppb levels) showed that the DNPH coated cartridge and the DNPH/acetonitrile impinger methods gave equivalent results. Blank levels of the DNPH-coated cartridges were studied as a function of storage time using various containers and temperature conditions. Canisters pressurized with zero-grade nitrogen provided the best storage device. Lower blank levels were also obtained when the cartridges were stored at lower temperatures. Blank levels appear tomore » equilibrate after six days of storage. To assure that quality data will be obtained, cartridges should be grouped according to batch number and blank levels should be determined prior to any field monitoring effort. Blank cartridge levels should be an order of magnitude lower than sample cartridge level. High performance liquid chromatography with UV detection proved to be a sensitive and stable analytical method for the DNPH derivatives.« less
NHEXAS PHASE I MARYLAND STUDY--QA ANALYTICAL RESULTS FOR PESTICIDE METABOLITES IN BLANKS
The Pesticide Metabolites in Blanks data set contains the analytical results of measurements of up to 4 pesticide metabolites in 14 blank samples from 13 households. Measurements were made in blank samples of urine. Blank samples were used to assess the potential for sample con...
U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--QA ANALYTICAL RESULTS FOR METALS IN BLANK SAMPLES
The Metals in Blank Samples data set contains the analytical results of measurements of up to 27 metals in 52 blank samples. Measurements were made in blank samples of dust, indoor air, food, water, and dermal wipe residue. Blank samples were used to assess the potential for sa...
Rattray, Gordon W.
2012-01-01
The U.S. Geological Survey, in cooperation with the U.S. Department of Energy, collects surface water and groundwater samples at and near the Idaho National Laboratory as part of a routine, site-wide, water-quality monitoring program. Quality-control samples are collected as part of the program to ensure and document the quality of environmental data. From 1996 to 2001, quality-control samples consisting of 204 replicates and 27 blanks were collected at sampling sites. Paired measurements from replicates were used to calculate variability (as reproducibility and reliability) from sample collection and analysis of radiochemical, chemical, and organic constituents. Measurements from field and equipment blanks were used to estimate the potential contamination bias of constituents. The reproducibility of measurements of constituents was calculated from paired measurements as the normalized absolute difference (NAD) or the relative standard deviation (RSD). The NADs and RSDs, as well as paired measurements with censored or estimated concentrations for which NADs and RSDs were not calculated, were compared to specified criteria to determine if the paired measurements had acceptable reproducibility. If the percentage of paired measurements with acceptable reproducibility for a constituent was greater than or equal to 90 percent, then the reproducibility for that constituent was considered acceptable. The percentage of paired measurements with acceptable reproducibility was greater than or equal to 90 percent for all constituents except orthophosphate (89 percent), zinc (80 percent), hexavalent chromium (53 percent), and total organic carbon (TOC; 38 percent). The low reproducibility for orthophosphate and zinc was attributed to calculation of RSDs for replicates with low concentrations of these constituents. The low reproducibility for hexavalent chromium and TOC was attributed to the inability to preserve hexavalent chromium in water samples and high variability with the analytical method for TOC. The reliability of measurements of constituents was estimated from pooled RSDs that were calculated for discrete concentration ranges for each constituent. Pooled RSDs of 15 to 33 percent were calculated for low concentrations of gross-beta radioactivity, strontium-90, ammonia, nitrite, orthophosphate, nickel, selenium, zinc, tetrachloroethene, and toluene. Lower pooled RSDs of 0 to 12 percent were calculated for all other concentration ranges of these constituents, and for all other constituents, except for one concentration range for gross-beta radioactivity, chloride, and nitrate + nitrite; two concentration ranges for hexavalent chromium; and TOC. Pooled RSDs for the 50 to 60 picocuries per liter concentration range of gross-beta radioactivity (reported as cesium-137) and the 10 to 60 milligrams per liter (mg/L) concentration range of nitrate + nitrite (reported as nitrogen [N]) were 17 percent. Chloride had a pooled RSD of 14 percent for the 20 to less than 60 mg/L concentration range. High pooled RSDs of 40 and 51 percent were calculated for two concentration ranges for hexavalent chromium and of 60 percent for TOC. Measurements from (1) field blanks were used to estimate the potential bias associated with environmental samples from sample collection and analysis, (2) equipment blanks were used to estimate the potential bias from cross contamination of samples collected from wells where portable sampling equipment was used, and (3) a source-solution blank was used to verify that the deionized water source-solution was free of the constituents of interest. If more than one measurement was available, the bias was estimated using order statistics and the binomial probability distribution. The source-solution blank had a detectable concentration of hexavalent chromium of 2 micrograms per liter. If this bias was from a source other than the source solution, then about 84 percent of the 117 hexavalent chromium measurements from environmental samples could have a bias of 10 percent or more. Of the 14 field blanks that were collected, only chloride (0.2 milligrams per liter) and ammonia (0.03 milligrams per liter as nitrogen), in one blank each, had detectable concentrations. With an estimated confidencelevel of 95 percent, at least 80 percent of the 1,987 chloride concentrations measured from all environmental samples had a potential bias of less than 8 percent. The ammonia bias, which may have occurred at the analytical laboratory, could produce a potential bias of 5-100 percent in eight potentially affected ammonia measurements. Of the 11 equipment blanks that were collected, chloride was detected in 4 of these blanks, sodium in 3 blanks, and sulfate and hexavalent chromium were each detected in 1 blank. The concentration of hexavalent chromium in the equipment blank was the same concentration as in the source-solution blank collected on the same day, which indicates that the hexavalent chromium in the equipment blank is probably from a source other than the portable sampling equipment, such as the sample bottles or the source-solution water itself. The potential bias for chloride, sodium, and sulfate measurements was estimated for environmental samples that were collected using portable sampling equipment. For chloride, it was estimated with 93 percent confidence that at least 80 percent of the measurements had a bias of less than 18 percent. For sodium and sulfate, it was estimated with 91 percent confidence that at least 70 percent of the measurements had a bias of less than 12 and 5 percent, respectively.
Paretti, Nicholas; Coes, Alissa L.; Kephart, Christopher M.; Mayo, Justine
2018-03-05
Tumacácori National Historical Park protects the culturally important Mission, San José de Tumacácori, while also managing a portion of the ecologically diverse riparian corridor of the Santa Cruz River. This report describes the methods and quality assurance procedures used in the collection of water samples for the analysis of Escherichia coli (E. coli), microbial source tracking markers, suspended sediment, water-quality parameters, turbidity, and the data collection for discharge and stage; the process for data review and approval is also described. Finally, this report provides a quantitative assessment of the quality of the E. coli, microbial source tracking, and suspended sediment data.The data-quality assessment revealed that bias attributed to field and laboratory contamination was minimal, with E. coli detections in only 3 out of 33 field blank samples analyzed. Concentrations in the field blanks were several orders of magnitude lower than environmental concentrations. The microbial source tracking (MST) field blank was below the detection limit for all MST markers analyzed. Laboratory blanks for E. coli at the USGS Arizona Water Science Center and laboratory blanks for MST markers at the USGS Ohio Water Microbiology Laboratory were all below the detection limit. Irreplicate data for E. coli and suspended sediment indicated that bias was not introduced to the data by combining samples collected using discrete sampling methods with samples collected using automatic sampling methods.The split and sequential E. coli replicate data showed consistent analytical variability and a single equation was developed to explain the variability of E. coli concentrations. An additional analysis of analytical variability for E. coli indicated analytical variability around 18 percent relative standard deviation and no trend was observed in the concentration during the processing and analysis of multiple split-replicates. Two replicate samples were collected for MST and individual markers were compared for a base flow and flood sample. For the markers found in common between the two types of samples, the relative standard deviation for the base flow sample was more than 3 times greater than the markers in the flood sample. Sequential suspended sediment replicates had a relative standard deviation of about 1.3 percent, indicating that environmental and analytical variability was minimal.A holding time review and laboratory study analysis supported the extended holding times required for this investigation. Most concentrations for flood and base-flow samples were within the theoretical variability specified in the most probable number approach suggesting that extended hold times did not overly influence the final concentrations reported.
Gray, James L.; Kanagy, Leslie K.; Furlong, Edward T.; McCoy, Jeff W.; Kanagy, Chris J.
2011-01-01
On April 22, 2010, the explosion on and subsequent sinking of the Deepwater Horizon oil drilling platform resulted in the release of crude oil into the Gulf of Mexico. At least 4.4 million barrels had been released into the Gulf of Mexico through July 15, 2010, 10 to 29 percent of which was chemically dispersed, primarily using two dispersant formulations. Initially, the dispersant Corexit 9527 was used, and when existing stocks of that formulation were exhausted, Corexit 9500 was used. Over 1.8 million gallons of the two dispersants were applied in the first 3 months after the spill. This report presents the development of an analytical method to analyze one of the primary surfactant components of both Corexit formulations, di(ethylhexyl) sodium sulfosuccinate (DOSS), the preliminary results, and the associated quality assurance/quality control (QA/QC) from samples collected from various points on the Gulf Coast between Texas and Florida. Seventy water samples and 8 field QC samples were collected before the predicted landfall of oil (pre-landfall) on the Gulf Coast, and 51 water samples and 10 field QC samples after the oil made landfall (post-landfall). Samples were collected in Teflon(Registered) bottles and stored at -20(degrees)C until analysis. Extraction of whole-water samples used sorption onto a polytetrafluoroethylene (PTFE) filter to isolate DOSS, with subsequent 50 percent methanol/water elution of the combined dissolved and particulate DOSS fractions. High-performance liquid chromatography/tandem mass spectrometry (LC/MS/MS) was used to identify and quantify DOSS by the isotope dilution method, using a custom-synthesized 13C4-DOSS labeled standard. Because of the ubiquitous presence of DOSS in laboratory reagent water, a chromatographic column was installed in the LC/MS/MS between the system pumps and the sample injector that separated this ambient background DOSS contamination from the sample DOSS, minimizing one source of blank contamination. Laboratory and field QA/QC for pre-landfall samples included laboratory reagent spike and blank samples, a total of 34 replicate analyses for the 78 environmental and field blank samples, and 11 randomly chosen laboratory matrix spike samples. Laboratory and field QA/QC for post-landfall samples included laboratory reagent spike and blank samples, a laboratory 'in-bottle' duplicate for each sample, and analysis of 24 randomly chosen laboratory matrix spike samples. Average DOSS recovery of 89(+/-)9.5 percent in all native (non-13C4-DOSS ) spikes was observed, with a mean relative percent difference between sample duplicates of 36 percent. The reporting limit for this analysis was 0.25 micrograms per liter due to blank limitations; DOSS was not detected in any samples collected in October (after oil landfall at certain study sites) above that concentration. It was detected prior to oil landfall above 0.25 micrograms per liter in 3 samples, but none exceeded the Environmental Protection Agency aquatic life criteria of 40 micrograms per liter.
NHEXAS PHASE I REGION 5 STUDY--QA ANALYTICAL RESULTS FOR METALS IN BLANKS
This data set includes analytical results for measurements of metals in 205 blank samples and for particles in 64 blank samples. Measurements were made for up to 12 metals in blank samples of air, dust, soil, water, food and beverages, blood, hair, and urine. Blank samples were u...
NHEXAS PHASE I MARYLAND STUDY--QA ANALYTICAL RESULTS FOR METALS IN BLANKS
The Metals in Blanks data set contains the analytical results of measurements of up to 11 metals in 115 blank samples from 58 households. Measurements were made in blank samples of indoor and outdoor air, drinking water, beverages, urine, and blood. Blank samples were used to a...
NHEXAS PHASE I MARYLAND STUDY--QA ANALYTICAL RESULTS FOR PESTICIDES IN BLANKS
The Pesticides in Blanks data set contains the analytical results of measurements of up to 20 pesticides in 70 blank samples from 46 households. Measurements were made in blank samples of indoor air, dust, soil, drinking water, food, beverages, and blood serum. Blank samples we...
NHEXAS PHASE I REGION 5 STUDY--QA ANALYTICAL RESULTS FOR VOCS IN BLANKS
This data set includes analytical results for measurements of VOCs in 88 blank samples. Measurements were made for up to 23 VOCs in blank samples of air, water, and blood. Blank samples were used to assess the potential for sample contamination during collection, storage, shipmen...
NHEXAS PHASE I ARIZONA STUDY--QA ANALYTICAL RESULTS FOR PESTICIDES IN BLANK SAMPLES
The Pesticides in Blank Samples data set contains the analytical results of measurements of up to 4 pesticides in 43 blank samples from 29 households. Measurements were made in blank samples of dust, indoor and outdoor air, food and beverages, blood, urine, and dermal wipe resid...
NHEXAS PHASE I ARIZONA STUDY--QA ANALYTICAL RESULTS FOR METALS IN BLANK SAMPLES
The Metals in Blank Samples data set contains the analytical results of measurements of up to 27 metals in 82 blank samples from 26 households. Measurements were made in blank samples of dust, indoor and outdoor air, personal air, food, beverages, blood, urine, and dermal wipe r...
Rattray, Gordon W.
2014-01-01
Quality-control (QC) samples were collected from 2002 through 2008 by the U.S. Geological Survey, in cooperation with the U.S. Department of Energy, to ensure data robustness by documenting the variability and bias of water-quality data collected at surface-water and groundwater sites at and near the Idaho National Laboratory. QC samples consisted of 139 replicates and 22 blanks (approximately 11 percent of the number of environmental samples collected). Measurements from replicates were used to estimate variability (from field and laboratory procedures and sample heterogeneity), as reproducibility and reliability, of water-quality measurements of radiochemical, inorganic, and organic constituents. Measurements from blanks were used to estimate the potential contamination bias of selected radiochemical and inorganic constituents in water-quality samples, with an emphasis on identifying any cross contamination of samples collected with portable sampling equipment. The reproducibility of water-quality measurements was estimated with calculations of normalized absolute difference for radiochemical constituents and relative standard deviation (RSD) for inorganic and organic constituents. The reliability of water-quality measurements was estimated with pooled RSDs for all constituents. Reproducibility was acceptable for all constituents except dissolved aluminum and total organic carbon. Pooled RSDs were equal to or less than 14 percent for all constituents except for total organic carbon, which had pooled RSDs of 70 percent for the low concentration range and 4.4 percent for the high concentration range. Source-solution and equipment blanks were measured for concentrations of tritium, strontium-90, cesium-137, sodium, chloride, sulfate, and dissolved chromium. Field blanks were measured for the concentration of iodide. No detectable concentrations were measured from the blanks except for strontium-90 in one source solution and one equipment blank collected in September and October 2004, respectively. The detectable concentrations of strontium-90 in the blanks probably were from a small source of strontium-90 contamination or large measurement variability, or both. Order statistics and the binomial probability distribution were used to estimate the magnitude and extent of any potential contamination bias of tritium, strontium-90, cesium-137, sodium, chloride, sulfate, dissolved chromium, and iodide in water-quality samples. These statistical methods indicated that, with (1) 87 percent confidence, contamination bias of cesium-137 and sodium in 60 percent of water-quality samples was less than the minimum detectable concentration or reporting level; (2) 92‒94 percent confidence, contamination bias of tritium, strontium-90, chloride, sulfate, and dissolved chromium in 70 percent of water-quality samples was less than the minimum detectable concentration or reporting level; and (3) 75 percent confidence, contamination bias of iodide in 50 percent of water-quality samples was less than the reporting level for iodide. These results support the conclusion that contamination bias of water-quality samples from sample processing, storage, shipping, and analysis was insignificant and that cross-contamination of perched groundwater samples collected with bailers during 2002–08 was insignificant.
Gravimetric Analysis of Particulate Matter using Air Samplers Housing Internal Filtration Capsules.
O'Connor, Sean; O'Connor, Paula Fey; Feng, H Amy; Ashley, Kevin
2014-10-01
An evaluation was carried out to investigate the suitability of polyvinyl chloride (PVC) internal capsules, housed within air sampling devices, for gravimetric analysis of airborne particles collected in workplaces. Experiments were carried out using blank PVC capsules and PVC capsules spiked with 0,1 - 4 mg of National Institute of Standards and Technology Standard Reference Material ® (NIST SRM) 1648 (Urban Particulate Matter) and Arizona Road Dust (Air Cleaner Test Dust). The capsules were housed within plastic closed-face cassette samplers (CFCs). A method detection limit (MDL) of 0,075 mg per sample was estimated. Precision S r at 0,5 - 4 mg per sample was 0,031 and the estimated bias was 0,058. Weight stability over 28 days was verified for both blanks and spiked capsules. Independent laboratory testing on blanks and field samples verified long-term weight stability as well as sampling and analysis precision and bias estimates. An overall precision estimate Ŝ rt of 0,059 was obtained. An accuracy measure of ±15,5% was found for the gravimetric method using PVC internal capsules.
Gravimetric Analysis of Particulate Matter using Air Samplers Housing Internal Filtration Capsules
O'Connor, Sean; O'Connor, Paula Fey; Feng, H. Amy
2015-01-01
Summary An evaluation was carried out to investigate the suitability of polyvinyl chloride (PVC) internal capsules, housed within air sampling devices, for gravimetric analysis of airborne particles collected in workplaces. Experiments were carried out using blank PVC capsules and PVC capsules spiked with 0,1 – 4 mg of National Institute of Standards and Technology Standard Reference Material® (NIST SRM) 1648 (Urban Particulate Matter) and Arizona Road Dust (Air Cleaner Test Dust). The capsules were housed within plastic closed-face cassette samplers (CFCs). A method detection limit (MDL) of 0,075 mg per sample was estimated. Precision Sr at 0,5 - 4 mg per sample was 0,031 and the estimated bias was 0,058. Weight stability over 28 days was verified for both blanks and spiked capsules. Independent laboratory testing on blanks and field samples verified long-term weight stability as well as sampling and analysis precision and bias estimates. An overall precision estimate Ŝrt of 0,059 was obtained. An accuracy measure of ±15,5% was found for the gravimetric method using PVC internal capsules. PMID:26435581
Hydrogeologic and chemical data for the O-Field area, Aberdeen Proving Ground, Maryland
Nemoff, P.R.; Vroblesky, D.A.
1989-01-01
O-Field, located at the Edgewood area of Aberdeen Proving Ground , Maryland, was periodically used for disposal of munitions, waste chemicals, and chemical-warfare agents from World War II through the 1950' s. This report includes various physical, geologic, chemical, and hydrologic data obtained from well-core, groundwater, surface water, and bottom-sediment sampling sites at and near the O-Field disposal area. The data are presented in tables and hydrographs. Three site-location maps are also included. Well-core data include lithologic logs for 11 well- cluster sites, grain-size distributions, various chemical characteristics, and confining unit characteristics. Groundwater data include groundwater chemistry, method blanks for volatile organic carbon, available data on volatile and base/neutral organics, and compilation of corresponding method blanks, chemical-warfare agents, explosive-related products, radionuclides, herbicides, and groundwater levels. Surface-water data include field-measured characteristics; concentrations of various inorganic constituents including arsenic; selected organic constituents with method blanks; detection limits of organics; and a compilation of information on corresponding acids, volatiles, and semivolatiles. Bottom- sediment data include inorganic properties and constituents; organic chemistry; detection limits for organic chemicals; a compilation of information on acids, volatiles, and semivolatiles; and method blanks corresponding to acids, volatiles, and semivolatiles. A set of 15 water- level hydrographs for the period March 1986 through September 1987 also is included in the report. (USGS)
Fitzgerald, S.A.
1997-01-01
This report contains the quality control results of the Western Lake Michigan Drainages study unit of the National Water Quality Assessment Program. Quality control samples were collected in the same manner and contemporaneously with environmental samples during the first highintensity study phase in the unit (1992 through 1995) and amounted to approximately 15 percent of all samples collected. The accuracy and precision of hundreds of chemical analyses of surface and ground-water, bed sediment, and tissue was determined through the collection and analysis of field blanks, field replicates and splits, matrix spikes, and surrogates. Despite the several detections of analytes in the field blanks, the concentrations of most constituents in the environmental samples will likely be an order of magnitude or higher than those in the blanks. However, frequent detections, and high concentrations, of dissolved organic carbon (DOC) in several surface and ground-water blanks are probably significant with respect to commonly measured environmental concentrations, and the environmental data will have to be qualified accordingly. The precision of sampling of water on a percent basis, as determined from replicates and splits, was generally proportional to the concentration of the constituents, with constituents present in relatively high concentrations generally having less sampling variability than those with relatively low concentrations. In general, analytes with relatively high variability between replicates were present at concentrations near the reporting limit or were associated with relatively small absolute concentration differences, or both. Precision of replicates compared to that for splits in bed sediment samples was similar, thus eliminating sampling as a major source of variability in analyte concentrations. In the case the phthalates in bed sediment, contamination in either the field or laboratory could have caused the relatively large variability between replicate samples and between split samples.Variability of analyte concentrations in tissue samples was relatively low, being 29 percent or less for all constituents. Recoveries of most laboratory schedule 2001/2010 pesticide spike compounds in surfacewater samples were reasonably good. Low intrinsic method recovery resulted in relatively low recovery forp,p'-DDE, metribuzin, and propargite. In the case of propargite, decomposition with the environmental sample matrices was also indicated. Recoveries of two compounds, cyanazine and thiobencarb, might have been biased high due to interferences. The one laboratory schedule 2050/2051 field matrix pesticide spike indicated numerous operational problems with this method that biased recoveries either low or high. Recoveries of pesticides from both pesticide schedules in field spikes of ground-water samples generally were similar to those of field matrix spikes of surface- water samples. High maximum recoveries were noted for tebuthiuron, disulfoton, DCPA, and permethrin, which indicates the possible presence of interferents in the matrices for these compounds. Problems in the recoveries of pesticides on schedule 2050/2051 from ground-water samples generally were the same as those for surfacewater samples. Recoveries of VOCs in field matrix spikes were reasonable when consideration was given for the use of the micropipettor that delivered only about 80 percent on average of the nominal mass of spiked analytes. Finally, the recoveries of most surrogate compounds in surface and ground-water samples were reasonable. Problems in sample handling (for example, spillage) were likely not the cause of any of the low recoveries of spiked compounds.
Wang, Bronwen; Mueller, Seth; Bailey, Elizabeth; Lee, Greg
2006-01-01
We report on the chemical analysis of water samples collected from the Taylor Mountains 1:250,000 quadrangle. Samples were collected as part of the multi-year U.S. Geological Survey's project -- Geologic and Mineral Deposit Data for Alaskan Economic Development. Data presented here are from water samples collected primarily in the northeastern part of the Taylor Mountains quadrangle. The data include samples taken from the Taylor Mountains C1, C2, D1, D2, and D4 1:63,360 scale quadrangles. The data are being released at this time with minimal interpretation. Site selection was based on a regional sampling strategy that focused on first and second order drainages. Water sampling site selection was based on landscape parameters that included physiography, wetland extent, lithological changes, and the cursory field review of the mineralogy from the pan concentrates. Stream water in the Taylor Mountians quadrangle is dominated by bicarbonate (HCO3-), though in a few samples more than 50% of the anionic charge can be attibuted to sulfate ( SO42-). The major-cation chemistry range from Ca/Mg dominated to a mix of Ca/Mg/Na+K. Good agreement was found between the major cation and anions in the duplicate samples. Many trace elements were at or near the method detection limit in these samples but good agreement was found between duplicate samples for elements with detectable concentrations. Major ion concentrations were below detection in all field blanks and the trace elements concentrations generally were below detection. However, Ta (range 0.9 -.1 ug/L) and Zn (1 to 3.5 ug/L) were detected in all blanks and Ba ( 0.24 ug/L) and Th (0.2 ug/L) were detected in one blank. There was good agreement between dupilicate total- and methyl- mercury and DOC samples; however, total mercury, methyl-mercury and dissolve organic carbon (DOC) were detected in the blank at 2.35 ng/L, 0.07 ng/L and 0.57 mg/L, respectively.
Gross, Eliza L.; Lindsey, Bruce D.; Rupert, Michael G.
2012-01-01
Field blank samples help determine the frequency and magnitude of contamination bias, and replicate samples help determine the sampling variability (error) of measured analyte concentrations. Quality control data were evaluated for calcium, magnesium, sodium, potassium, chloride, sulfate, fluoride, silica, and total dissolved solids. A 99-percent upper confidence limit is calculated from field blanks to assess the potential for contamination bias. For magnesium, potassium, chloride, sulfate, and fluoride, potential contamination in more than 95 percent of environmental samples is less than or equal to the common maximum reporting level. Contamination bias has little effect on measured concentrations greater than 4.74 mg/L (milligrams per liter) for calcium, 14.98 mg/L for silica, 4.9 mg/L for sodium, and 120 mg/L for total dissolved solids. Estimates of sampling variability are calculated for high and low ranges of concentration for major ions and total dissolved solids. Examples showing the calculation of confidence intervals and how to determine whether measured differences between two water samples are significant are presented.
Spahr, N.E.; Boulger, R.W.
1997-01-01
Quality-control samples provide part of the information needed to estimate the bias and variability that result from sample collection, processing, and analysis. Quality-control samples of surface water collected for the Upper Colorado River National Water-Quality Assessment study unit for water years 1995?96 are presented and analyzed in this report. The types of quality-control samples collected include pre-processing split replicates, concurrent replicates, sequential replicates, post-processing split replicates, and field blanks. Analysis of the pre-processing split replicates, concurrent replicates, sequential replicates, and post-processing split replicates is based on differences between analytical results of the environmental samples and analytical results of the quality-control samples. Results of these comparisons indicate that variability introduced by sample collection, processing, and handling is low and will not affect interpretation of the environmental data. The differences for most water-quality constituents is on the order of plus or minus 1 or 2 lowest rounding units. A lowest rounding unit is equivalent to the magnitude of the least significant figure reported for analytical results. The use of lowest rounding units avoids some of the difficulty in comparing differences between pairs of samples when concentrations span orders of magnitude and provides a measure of the practical significance of the effect of variability. Analysis of field-blank quality-control samples indicates that with the exception of chloride and silica, no systematic contamination of samples is apparent. Chloride contamination probably was the result of incomplete rinsing of the dilute cleaning solution from the outlet ports of the decaport sample splitter. Silica contamination seems to have been introduced by the blank water. Sampling and processing procedures for water year 1997 have been modified as a result of these analyses.
Methods to assess carbonaceous aerosol sampling artifacts for IMPROVE and other long-term networks.
Watson, John G; Chow, Judith C; Chen, L W Antony; Frank, Neil H
2009-08-01
Volatile organic compounds (VOCs) and semi-volatile organic compounds (SVOCs) adsorb to quartz fiber filters during fine and coarse particulate matter (PM2.5 and PM10, respectively) sampling for thermal/optical carbon analysis that measures organic carbon (OC) and elemental carbon (EC). Particulate SVOCs can evaporate after collection, with a small portion adsorbed within the filter. Adsorbed organic gases are measured as particulate OC, so passive field blanks, backup filters, prefilter organic denuders, and regression methods have been applied to compensate for positive OC artifacts in several long-term chemical speciation networks. Average backup filter OC levels from the Interagency Monitoring of Protected Visual Environments (IMPROVE) network were approximately 19% higher than field blank values. This difference is within the standard deviation of the average and likely results from low SVOC concentrations in the rural to remote environments of most IMPROVE sites. Backup filters from an urban (Fort Meade, MD) site showed twice the OC levels of field blanks. Sectioning backup filters from top to bottom showed nonuniform OC densities within the filter, contrary to the assumption that VOCs and SVOCs on a backup filter equal those on the front filter. This nonuniformity may be partially explained by evaporation and readsorption of vapors in different parts of the front and backup quartz fiber filter owing to temperature, relative humidity, and ambient concentration changes throughout a 24-hr sample duration. OC-PM2.5 regression analysis and organic denuder approaches demonstrate negative sampling artifact from both Teflon membrane and quartz fiber filters.
White HDPE bottles as source of serious contamination of water samples with Ba and Zn.
Reimann, Clemens; Grimstvedt, Andreas; Frengstad, Bjørn; Finne, Tor Erik
2007-03-15
During a recent study of surface water quality factory new white high-density polyethylene (HDPE) bottles were used for collecting the water samples. According to the established field protocol of the Geological Survey of Norway the bottles were twice carefully rinsed with water in the field prior to sampling. Several blank samples using milli-Q (ELGA) water (>18.2 MOmega) were also prepared. On checking the analytical results the blanks returned values of Ag, Ba, Sr, V, Zn and Zr. For Ba and Zn the values (c. 300 microg/l and 95 microg/l) were about 10 times above the concentrations that can be expected in natural waters. A laboratory test of the bottles demonstrated that the bottles contaminate the samples with significant amounts of Ba and Zn and some Sr. Simple acid washing of the bottles prior to use did not solve the contamination problem for Ba and Zn. The results suggest that there may exist "clean" and "dirty" HDPE bottles depending on manufacturer/production process. When collecting water samples it is mandatory to check bottles regularly as a possible source of contamination.
40 CFR 53.58 - Operational field precision and blank test.
Code of Federal Regulations, 2011 CFR
2011-07-01
... samplers are also subject to a test for possible deposition of particulate matter on inactive filters... deposition is defined as the mass of material inadvertently deposited on a sample filter that is stored in a... electrical power to accommodate three test samplers are required. (2) Teflon sample filters, as specified in...
Quality-control design for surface-water sampling in the National Water-Quality Network
Riskin, Melissa L.; Reutter, David C.; Martin, Jeffrey D.; Mueller, David K.
2018-04-10
The data-quality objectives for samples collected at surface-water sites in the National Water-Quality Network include estimating the extent to which contamination, matrix effects, and measurement variability affect interpretation of environmental conditions. Quality-control samples provide insight into how well the samples collected at surface-water sites represent the true environmental conditions. Quality-control samples used in this program include field blanks, replicates, and field matrix spikes. This report describes the design for collection of these quality-control samples and the data management needed to properly identify these samples in the U.S. Geological Survey’s national database.
NASA Astrophysics Data System (ADS)
Weiss-Penzias, P. S.; Heim, W. A.; Fernandez, D.; Coale, K. H.; Oliphant, A. J.; Dann, D.; Porter, M.; Hoskins, D.; Dodge, C.
2014-12-01
This project investigates the mercury content in summertime Pacific coastal fog in California and whether fog could be an important vector for ocean emissions of mercury to be deposited via fog drip to upland coastal ecosystems. Efforts began in early 2014 with the building of 7 active-strand fog collectors based on the Colorado State University Caltech CASCC design. The new UCSC CASCC includes doors sealing the collector which open under microcomputer control based on environmental sensing (relative humidity). Seven sites spanning from Trinidad in the north to Marina in the south have collected samples June-August 2014 under a project called FogNet. Fog conditions were favorable for collecting large water volumes (> 250 mL) at many sites. Fog samplers were cleaned with soap and deionized water daily and field blanks taken immediately following cleaning. Fog water samples were collected overnight, split into an aliquot for anion and DOC/DIC analysis and the remaining sample was acidified. Monomethyl mercury (MMHg) concentrations in samples and field blanks for 3 sites in FogNet are shown in the accompanying figure. The range of MMHg concentrations from 10 fog water samples > 100 mL in volume was 0.9-9.3 ng/L (4.5-46.4 pM). Elevated MMHg concentrations (> 5 ng/L, 25 pM) were observed at 2 sites: UC Santa Cruz and Bodega Bay. The field blanks produced MMHg concentrations of 0.08-0.4 ng/L (0.4-2.0 pM), which was on average < 10% of the sample concentration and suggests the artifact due to sampling was small. The observed MMHg concentrations in fog water observed is this study are 1-2 orders of magnitude greater than MMHg concentrations seen previously in rain water samples from the California coast suggesting an additional source of MMHg to fog. Shipboard measurements of dimethyl mercury (DMHg) in coastal California seawater during the time period of FogNet operations (summer 2014) reveal surface waters that were supersaturated in DMHg which represents a potential source of organic mercury to the overlying fog bank.
Salgueiro-González, N; Concha-Graña, E; Turnes-Carou, I; Muniategui-Lorenzo, S; López-Mahía, P; Prada-Rodríguez, D
2012-11-15
Blank contamination is a notorious problem in the ultratrace analysis of alkylphenols and bisphenol A. The achievement of low detection limits is complicated due to the high background signals. Furthermore, overestimations and underestimations in the analytical results can occur when blank levels are not stable. Thus, a review of sources of blank contamination in this type of analysis was carried out. Several sources of contamination were identified and useful guidelines are proposed for the determination of these compounds in water samples by liquid chromatography coupled with mass spectrometry. The system contamination was maintained below 0.09 ng (reagent blank) for all compounds and below 0.003 μg L(-1) (procedure blank). The main improvement was obtained by using LC-MS grade solvent in the mobile phase and PTFE syringe filters for the filtration of the sample extracts. Sample handling aspects such as filtration and storage of the water samples were also considered. The filtration of the samples should be avoided because both contamination and adsorption problems were observed when different kinds of filters were assayed. The refrigerated storage of water samples should be limited to 5 days (without addition of methanol) or 8 days (with 5% methanol). Copyright © 2012 Elsevier B.V. All rights reserved.
Improved confidence intervals when the sample is counted an integer times longer than the blank.
Potter, William Edward; Strzelczyk, Jadwiga Jodi
2011-05-01
Past computer solutions for confidence intervals in paired counting are extended to the case where the ratio of the sample count time to the blank count time is taken to be an integer, IRR. Previously, confidence intervals have been named Neyman-Pearson confidence intervals; more correctly they should have been named Neyman confidence intervals or simply confidence intervals. The technique utilized mimics a technique used by Pearson and Hartley to tabulate confidence intervals for the expected value of the discrete Poisson and Binomial distributions. The blank count and the contribution of the sample to the gross count are assumed to be Poisson distributed. The expected value of the blank count, in the sample count time, is assumed known. The net count, OC, is taken to be the gross count minus the product of IRR with the blank count. The probability density function (PDF) for the net count can be determined in a straightforward manner.
Sampling for mercury at subnanogram per litre concentrations for load estimation in rivers
Colman, J.A.; Breault, R.F.
2000-01-01
Estimation of constituent loads in streams requires collection of stream samples that are representative of constituent concentrations, that is, composites of isokinetic multiple verticals collected along a stream transect. An all-Teflon isokinetic sampler (DH-81) cleaned in 75??C, 4 N HCl was tested using blank, split, and replicate samples to assess systematic and random sample contamination by mercury species. Mean mercury concentrations in field-equipment blanks were low: 0.135 ng??L-1 for total mercury (??Hg) and 0.0086 ng??L-1 for monomethyl mercury (MeHg). Mean square errors (MSE) for ??Hg and MeHg duplicate samples collected at eight sampling stations were not statistically different from MSE of samples split in the laboratory, which represent the analytical and splitting error. Low fieldblank concentrations and statistically equal duplicate- and split-sample MSE values indicate that no measurable contamination was occurring during sampling. Standard deviations associated with example mercury load estimations were four to five times larger, on a relative basis, than standard deviations calculated from duplicate samples, indicating that error of the load determination was primarily a function of the loading model used, not of sampling or analytical methods.
Medalie, Laura; Martin, Jeffrey D.
2017-08-14
Potential contamination bias was estimated for 8 nutrient analytes and 40 pesticides in stream water collected by the U.S. Geological Survey at 147 stream sites from across the United States, and representing a variety of hydrologic conditions and site types, for water years 2002–12. This study updates previous U.S. Geological Survey evaluations of potential contamination bias for nutrients and pesticides. Contamination is potentially introduced to water samples by exposure to airborne gases and particulates, from inadequate cleaning of sampling or analytic equipment, and from inadvertent sources during sample collection, field processing, shipment, and laboratory analysis. Potential contamination bias, based on frequency and magnitude of detections in field blanks, is used to determine whether or under what conditions environmental data might need to be qualified for the interpretation of results in the context of comparisons with background levels, drinking-water standards, aquatic-life criteria or benchmarks, or human-health benchmarks. Environmental samples for which contamination bias as determined in this report applies are those from historical U.S. Geological Survey water-quality networks or programs that were collected during the same time frame and according to the same protocols and that were analyzed in the same laboratory as field blanks described in this report.Results from field blanks for ammonia, nitrite, nitrite plus nitrate, orthophosphate, and total phosphorus were partitioned by analytical method; results from the most commonly used analytical method for total phosphorus were further partitioned by date. Depending on the analytical method, 3.8, 9.2, or 26.9 percent of environmental samples, the last of these percentages pertaining to all results from 2007 through 2012, were potentially affected by ammonia contamination. Nitrite contamination potentially affected up to 2.6 percent of environmental samples collected between 2002 and 2006 and affected about 3.3 percent of samples collected between 2007 and 2012. The percentages of environmental samples collected between 2002 and 2011 that were potentially affected by nitrite plus nitrate contamination were 7.3 for samples analyzed with the low-level method and 0.4 for samples analyzed with the standard-level method. These percentages increased to 14.8 and 2.2 for samples collected in 2012 and analyzed using replacement low- and standard-level methods, respectively. The maximum potentially affected concentrations for nitrite and for nitrite plus nitrate were much less than their respective maximum contamination levels for drinking-water standards. Although contamination from particulate nitrogen can potentially affect up to 21.2 percent and that from total Kjeldahl nitrogen can affect up to 16.5 percent of environmental samples, there are no critical or background levels for these substances.For total nitrogen, orthophosphate, and total phosphorus, contamination in a small percentage of environmental samples might be consequential for comparisons relative to impairment risks or background levels. At the low ends of the respective ranges of impairment risk for these nutrients, contamination in up to 5 percent of stream samples could account for at least 23 percent of measured concentrations of total nitrogen, for at least 40 or 90 percent of concentrations of orthophosphate, depending on the analytical method, and for 31 to 76 percent of concentrations of total phosphorus, depending on the time period.Twenty-six pesticides had no detections in field blanks. Atrazine with 12 and metolachlor with 11 had the highest number of detections, mostly occurring in spring or early summer. At a 99-percent level of confidence, contamination was estimated to be no greater than the detection limit in at least 98 percent of all samples for 38 of 40 pesticides. For metolachlor and atrazine, potential contamination was no greater than 0.0053 and 0.0093 micrograms per liter in 98 percent of samples. For 11 of 14 pesticides with at least one detection, the maximum potentially affected concentration of the environmental sample was less than their respective human-health or aquatic-life benchmarks. Small percentages of environmental samples had concentrations high enough that atrazine contamination potentially could account for the entire aquatic-life benchmark for acute effects on nonvascular plants, that dieldrin contamination could account for up to 100 percent of the cancer health-based screening level, or that chlorpyrifos contamination could account for 13 or 12 percent of the concentrations in the aquatic-life benchmarks for chronic effects on invertebrates or the criterion continuous concentration for chronic effects on aquatic life.
Code of Federal Regulations, 2011 CFR
2011-07-01
... representative of the air entering the abatement site. c. Two field blanks are to be taken by removing the cap... of Sample Data Quality Objectives is shown in the following Table II: EC01AP92.003 C. Sample Shipment... or the Burdette procedure (Ref. 7 of Unit II.J.) ii. Plasma etching of the collapsed filter is...
Code of Federal Regulations, 2010 CFR
2010-07-01
... representative of the air entering the abatement site. c. Two field blanks are to be taken by removing the cap... of Sample Data Quality Objectives is shown in the following Table II: EC01AP92.003 C. Sample Shipment... or the Burdette procedure (Ref. 7 of Unit II.J.) ii. Plasma etching of the collapsed filter is...
Method and apparatus for inspecting reflection masks for defects
Bokor, Jeffrey; Lin, Yun
2003-04-29
An at-wavelength system for extreme ultraviolet lithography mask blank defect detection is provided. When a focused beam of wavelength 13 nm is incident on a defective region of a mask blank, three possible phenomena can occur. The defect will induce an intensity reduction in the specularly reflected beam, scatter incoming photons into an off-specular direction, and change the amplitude and phase of the electric field at the surface which can be monitored through the change in the photoemission current. The magnitude of these changes will depend on the incident beam size, and the nature, extent and size of the defect. Inspection of the mask blank is performed by scanning the mask blank with 13 nm light focused to a spot a few .mu.m in diameter, while measuring the reflected beam intensity (bright field detection), the scattered beam intensity (dark-field detection) and/or the change in the photoemission current.
Bour, Amy L; Walker, Brett D; Broek, Taylor A B; McCarthy, Matthew D
2016-04-05
Compound-specific radiocarbon analysis (CSRA) of amino acids (AAs) is of great interest as a proxy for organic nitrogen (N) cycling rates, dating archeological bone collagen, and investigating processes shaping the biogeochemistry of global N reservoirs. However, recoverable quantities of individual compounds from natural samples are often insufficient for radiocarbon ((14)C) analyses (<50 μg C). Constraining procedural carbon (C) blanks and their isotopic contributions is critical for reporting of accurate CSRA measurements. Here, we report the first detailed quantification of C blanks (including sources, magnitudes, and variability) for a high-pressure liquid chromatography (HPLC) method designed to purify individual AAs from natural samples. We used pairs of AA standards with either modern (M) or dead (D) fraction modern (Fm) values to quantify MC and DC blanks within several chromatographic regions. Blanks were determined for both individual and mixed AA standard injections with peak loadings ranging from 10 to 85 μg C. We found 0.8 ± 0.4 μg of MC and 1.0 ± 0.5 μg of DC were introduced by downstream sample preparation (drying, combustion, and graphitization), which accounted for essentially the entire procedural blank for early eluting AAs. For late-eluting AAs, higher eluent organic content and fraction collected volumes contributed to total blanks of 1.5 ± 0.75 μg of MC and 3.0 ± 1.5 μg of DC. Our final measurement uncertainty for 20 μg of C of most AAs was ±0.02 Fm, although sample size requirements are larger for similar uncertainty in late-eluting AAs. These results demonstrate the first CSRA protocol for many protein AAs with uncertainties comparable to the lowest achieved in prior studies.
Seeing Red and Shooting Blanks: A Study of Red Quasars and Blank Field X-Ray Sources
NASA Technical Reports Server (NTRS)
Elvis, Martin; Oliversen, Ronald J. (Technical Monitor)
2002-01-01
We have identified a population of 'blank field sources' (or 'blanks') among the ROSAT (Roentgen Satellite) bright unidentified X-ray sources with faint optical counterparts. The extreme X-ray over optical flux ratio of blank field sources is not compatible with the main classes of X-ray emitters except for extreme BL Lacertae objects at fx/fv is equal to or less than 35. From the analysis of ROSAT archival data we found evidence for only three sources, out of 16, needing absorption in excess of the Galactic value and no indication of variability. We also found evidence for an extended nature for only one of the five blanks with a serendipitous HRI (High Resolution Imager) detection; this source (1WGA J1226.9+3332) was confirmed as a z=0.89 cluster of galaxies. Palomar images reveal the presence of a red (O - E is equal to or greater than 2) counterpart in the X-ray error circle for six blanks. The identification process brought to the discovery of another high z cluster of galaxies, one (possibly extreme) BL Lac and two apparently normal type 1 AGNs (Active Galactic Nuclei). These AGNs, together with four more AGN-like objects seem to form a well defined group: they present type 1 X-ray spectra but red Palomar counterparts. We discuss the possible explanations for the discrepancy between the X-ray and optical data, among which: a suppressed big blue bump emission, an extreme dust to gas (approximately 40 - 60 the Galactic ratio) ratio value and a high redshift (z is greater than or equal to 3.5) QSO (Quasi-Stellar Object) nature. These AGN-like blanks seem to be the bright (and easier to study) analogs of the sources which are being found in deep Chandra observations. Five more blanks have a still an unknown nature.
The Particulate Matter in Blank Samples data set contains the analytical results for measurements of two particle sizes in 12 samples. Filters were pre-weighed, loaded into impactors, kept unexposed in the laboratory, unloaded and post-weighed. Positive weight gains for laborat...
Seeing Red and Shooting Blanks: A Study of Red Quasars And Blank Field X-Ray Sources
NASA Technical Reports Server (NTRS)
Oliversen, Ronald J. (Technical Monitor); Elvis, Martin
2003-01-01
The primary source catalog of 'blanks' (bright ROSAT sources with no optical counterparts) has been published in the Astrophysical Journal. The first follow-up paper has also been published. This paper used a combination of ROSAT, Chandra and ground based data to convincingly identify one of the blanks as a Ultra-luminous X-ray source (ULX) in a spiral galaxy. A paper detailing optical and near-IR imaging observations of the remaining sources is underway.
Guerreiro, António; Soares, Ana; Piletska, Elena; Mattiasson, Bo; Piletsky, Sergey
2008-03-31
Molecularly imprinted (MIP) and blank polymers with affinity for nonylphenol were designed using computational modelling. Chromatographic tests demonstrated higher affinity of imprinted polymers towards the template nonylphenol as compared with blank polymers. The performance of both polymers in solid-phase extraction was however very similar. Both blank and imprinted polymers appeared to be suitable for the removal and pre-concentration of nonylphenol from contaminated water samples with 99% efficiency of the recovery. The commercial resins PH(EC) (Biotage) and C18 (Varian) tested in the same conditions used for comparative purposes had recovery rate <84%. The polymer capacity for nonylphenol was 231 mg g(-1) for blank and 228 mg g(-1) for MIP. The synthesised materials can have significance for sample pre-concentration and environmental analysis of this class of compounds.
Wang, Bronwen; Mueller, Seth; Stetson, Sarah; Bailey, Elizabeth; Lee, Greg
2006-01-01
We report on the chemical analysis of water samples collected from the Taylor Mountains 1:250,000-scale quadrangle. Parameters for which data are reported include pH, conductivity, water temperature, major cation and anion concentrations, trace-element concentrations, and dissolved organic-carbon concentrations. Samples were collected as part of a multiyear U.S. Geological Survey project 'Geologic and Mineral Deposit Data for Alaskan Economic Development.' Data presented here are from samples collected in June and July of 2005. The data are being released at this time with minimal interpretation. This is the second release of aqueous geochemical data from this project; 2004 aqueous geochemical data were published previously (Wang and others, 2006). The data in this report augment but do not duplicate or supersede the previous data release. Site selection was based on a regional sampling strategy that focused on first- and second-order drainages. Water sample site selection was based on landscape parameters that included physiography, wetland extent, lithological changes, and a cursory field review of mineralogy from pan concentrates. Stream water in the Taylor Mountians quadrangle is dominated by bicarbonate (HCO3-), though in a few samples more than 50 percent of the anionic charge can be attributed to sulfate (SO42-). The major-cation chemistry ranges from Ca2+/Mg2+ dominated to a mix of Ca2+/Mg2+/Na++K+. In general, good agreement was found between the major cations and anions in the duplicate samples. Many trace elements in these samples were at or near the analytical method detection limit, but good agreement was found between duplicate samples for elements with detectable concentrations. With the exception of a total mercury concentration of 0.33 ng/L detected in a field blank, field blank major-ion and trace-elements concentrations were below detection.
Microbial source tracking markers at three inland recreational lakes in Ohio, 2011
Francy, Donna S.; Stelzer, Erin A.
2012-01-01
During the 2011 recreational season, samples were collected for E. coli and microbial source tracking (MST) marker concentrations to begin to understand potential sources of fecal contamination at three inland recreational lakes in Ohio - Buckeye, Atwood, and Tappan Lakes. The results from 32 regular samples, 4 field blanks, and 7 field replicates collected at 5 sites are presented in this report. At the three lakes, the ruminant-associated marker was found most often (57-73 percent of samples) but at estimated quantities, followed by the dog-associated marker (30-43 percent of samples). The human-associated marker was found in 14 and 50 percent of samples from Atwood and Tappan Lakes, respectively, but was not found in any samples from the two Buckeye Lake sites. The gull-associated marker was detected in only two samples, both from Tappan Lake.
Blank corrections for ramped pyrolysis radiocarbon dating of sedimentary and soil organic carbon.
Fernandez, Alvaro; Santos, Guaciara M; Williams, Elizabeth K; Pendergraft, Matthew A; Vetter, Lael; Rosenheim, Brad E
2014-12-16
Ramped pyrolysis (RP) targets distinct components of soil and sedimentary organic carbon based on their thermochemical stabilities and allows the determination of the full spectrum of radiocarbon ((14)C) ages present in a soil or sediment sample. Extending the method into realms where more precise ages are needed or where smaller samples need to be measured involves better understanding of the blank contamination associated with the method. Here, we use a compiled data set of RP measurements of samples of known age to evaluate the mass of the carbon blank and its associated (14)C signature, and to assess the performance of the RP system. We estimate blank contamination during RP using two methods, the modern-dead and the isotope dilution method. Our results indicate that during one complete RP run samples are contaminated by 8.8 ± 4.4 μg (time-dependent) of modern carbon (MC, fM ∼ 1) and 4.1 ± 5.5 μg (time-independent) of dead carbon (DC, fM ∼ 0). We find that the modern-dead method provides more accurate estimates of uncertainties in blank contamination; therefore, the isotope dilution method should be used with caution when the variability of the blank is high. Additionally, we show that RP can routinely produce accurate (14)C dates with precisions ∼100 (14)C years for materials deposited in the last 10,000 years and ∼300 (14)C years for carbon with (14)C ages of up to 20,000 years.
Mercury Deposition Network Site Operator Training for the System Blank and Blind Audit Programs
Wetherbee, Gregory A.; Lehmann, Christopher M.B.
2008-01-01
The U.S. Geological Survey operates the external quality assurance project for the National Atmospheric Deposition Program/Mercury Deposition Network. The project includes the system blank and blind audit programs for assessment of total mercury concentration data quality for wet-deposition samples. This presentation was prepared to train new site operators and to refresh experienced site operators to successfully process and submit system blank and blind audit samples for chemical analysis. Analytical results are used to estimate chemical stability and contamination levels of National Atmospheric Deposition Program/Mercury Deposition Network samples and to evaluate laboratory variability and bias.
Gartner, J.W.; Ganju, N.K.; ,
2002-01-01
Many streams and rivers for which the US Geological Survey must provide discharge measurements are too shallow to apply existing acoustic Doppler current profiler techniques for flow measurements of satisfactory quality. Because the same transducer is used for both transmitting and receiving acoustic signals in most Doppler current profilers, some small time delay is required for acoustic "ringing" to be damped out of transducers before meaningful measurements can be made. The result of that time delay is that velocity measurements cannot be made close to the transducer thus limiting the usefulness of these instruments in shallow regions. Manufacturers and users are constantly striving for improvements to acoustic instruments which would permit useful discharge measurements in shallow rivers and streams that are still often measured with techniques and instruments more than a century old. One promising area of advance appeared to be reduction of time delay (blank) required between transmitting and receiving signals during acoustic velocity measurements. Development of a low- or zero-blank transducer by RD Instruments3 held promise that velocity measurements could be made much closer to the transducer and thus in much shallower water. Initial experience indicates that this is not the case; limitation of measurement quality appears to be related to the physical presence of the transducer itself within the flow field. The limitation may be the result of changes to water flow pattern close to the transducer rather than transducer ringing characteristics as a function of blanking distance. Results of field experiments are discussed that support this conclusion and some minimum measurement distances from transducer are suggested based on water current speed and ADCP sample modes.
NASA Astrophysics Data System (ADS)
Verkouteren, R. Michael; Klouda, George A.; Currie, Lloyd A.; Donahue, Douglas J.; Jull, A. J. Timothy; Linick, T. W.
1987-11-01
A technique has been developed at NBS for the production of high quality targets for radiocarbon analysis by accelerator mass spectrometry (AMS). Our process optimizes chemical yields, ion currents and characterizes the chemical blank. The approach encompasses sample combustion to CO 2, catalytic reduction of CO 2 by Zn to CO, reduction to graphitic carbon on high-purity iron wool and in situ formation of a homogeneous iron-carbon bead; all steps are performed in a closed system. The total measurement system blank and variability are considered in the light of contributions from combustion, iron wool, reduction, bead formation and instrument blank. Additionally, use of this approach provides an increase in throughput, i.e. the effective management of large numbers of samples. Chemical yields for 50-800 μg C samples deposited on 15 mg iron wool were greater than 90%. Integrated 12C - ion currents observed were significant, being 4-64% of those observed in pure graphite. These currents are about an order of magnitude greater than those expected from dilution of graphite with an inert substrate. Isotopic accuracy, precision and blank were assessed by measuring the {14C }/{13C } ratios of a series of targets prepared from dead carbon and oxalic acid (SRM 4990C). Each target was typically measured for one hour; bead consumption was estimated at 5% to 10%. System blank subsequent to combustion was equivalent to (2.2 ± 0.5) μg modern carbon (chemistry + instrument); combustion blank currently stands at (0.4 ± 0.1) (SE, n = 6) μg C.
Menheer, M.A.; Brigham, M.E.
1997-01-01
Quality-control data demonstrated that most constituents measured for this study yielded reproducible data, with low to undetectable contamination from the sampling and analytical procedures. Several constituents were occasionally or frequently detected in blank samples at levels similar to low-concentration ground-water-quality samples. For example, iron was detected in 75 percent of the blank samples, with a maximum concentration of 27 [ig/L, indicating that iron contamination may interfere with its determination at low levels in ground waters. Copper, aluminum, and dissolved organic carbon concentrations in blank samples overlap those determined in ground-waterquality samples, thereby precluding quantitative reporting of those constituents. Most pesticide data are reproducible, with minimal bias. Some pesticides had low but consistent recoveries; these data may be useful if spike and surrogate data are carefully considered. Data for some pesticides measured in this study should not be quantitatively reported or used, because they may underestimate the concentrations of those pesticides in ground waters.
Cone of Darkness: Finding Blank-sky Positions for Multi-object Wide-field Observations
NASA Astrophysics Data System (ADS)
Lorente, N. P. F.
2014-05-01
We present the Cone of Darkness, an application to automatically configure blank-sky positions for a series of stacked, wide-field observations, such as those carried out by the SAMI instrument on the Anglo-Australian Telescope (AAT). The Sydney-AAO Multi-object Integral field spectrograph (SAMI) uses a plug-plate to mount its 13×61 core imaging fibre bundles (hexabundles) in the optical plane at the telescope's prime focus. To make the most efficient use of each plug-plate, several observing fields are typically stacked to produce a single plate. When choosing blank-sky positions for the observations it is most effective to select these such that one set of 26 holes gives valid sky positions for all fields on the plate. However, when carried out manually this selection process is tedious and includes a significant risk of error. The Cone of Darkness software aims to provide uniform blank-sky position coverage over the field of observation, within the limits set by the distribution of target positions and the chosen input catalogs. This will then facilitate the production of the best representative median sky spectrum for use in sky subtraction. The application, written in C++, is configurable, making it usable for a range of instruments. Given the plate characteristics and the positions of target holes, the software segments the unallocated space on the plate and determines the position which best fits the uniform distribution requirement. This position is checked, for each field, against the selected catalog using a TAP ADQL search. The process is then repeated until the desired number of sky positions is attained.
Koller, Marianne; Becker, Christian; Thiermann, Horst; Worek, Franz
2010-05-15
The purpose of this study was to check the applicability of different analytical methods for the identification of unknown nerve agents in human body fluids. Plasma and urine samples were spiked with nerve agents (plasma) or with their metabolites (urine) or were left blank. Seven random samples (35% of all samples) were selected for the verification test. Plasma was worked up for unchanged nerve agents and for regenerated nerve agents after fluoride-induced reactivation of nerve agent-inhibited butyrylcholinesterase. Both extracts were analysed by GC-MS. Metabolites were extracted from plasma and urine, respectively, and were analysed by LC-MS. The urinary metabolites and two blank samples could be identified without further measurements, plasma metabolites and blanks were identified in six of seven samples. The analysis of unchanged nerve agent provided five agents/blanks and the sixth agent after further investigation. The determination of the regenerated agents also provided only five clear findings during the first screening because of a rather noisy baseline. Therefore, the sample preparation was extended by a size exclusion step performed before addition of fluoride which visibly reduced baseline noise and thus improved identification of the two missing agents. The test clearly showed that verification should be performed by analysing more than one biomarker to ensure identification of the agent(s). Copyright (c) 2010 Elsevier B.V. All rights reserved.
Code of Federal Regulations, 2013 CFR
2013-01-01
... lines are provided in section L for any additional settlement charges. Blank lines are also provided for additional insertions in sections J and K. The names of the recipients of the settlement charges in section L... blank lines. Lines and columns in section J which relate to the Borrower's transaction may be left blank...
Code of Federal Regulations, 2012 CFR
2012-01-01
... lines are provided in section L for any additional settlement charges. Blank lines are also provided for additional insertions in sections J and K. The names of the recipients of the settlement charges in section L... blank lines. Lines and columns in section J which relate to the Borrower's transaction may be left blank...
Blanks: a computer program for analyzing furniture rough-part needs in standard-size blanks
Philip A. Araman
1983-01-01
A computer program is described that allows a company to determine the number of edge-glued, standard-size blanks required to satisfy its rough-part needs for a given production period. Yield and cost information also is determined by the program. A list of the program inputs, outputs, and uses of outputs is described, and an example analysis with sample output is...
Lin, Jingquan; Weber, Nils; Escher, Matthias; Maul, Jochen; Han, Hak-Seung; Merkel, Michael; Wurm, Stefan; Schönhense, Gerd; Kleineberg, Ulf
2008-09-29
A photoemission electron microscope based on a new contrast mechanism "interference contrast" is applied to characterize extreme ultraviolet lithography mask blank defects. Inspection results show that positioning of interference destructive condition (node of standing wave field) on surface of multilayer in the local region of a phase defect is necessary to obtain best visibility of the defect on mask blank. A comparative experiment reveals superiority of the interference contrast photoemission electron microscope (Extreme UV illumination) over a topographic contrast one (UV illumination with Hg discharge lamp) in detecting extreme ultraviolet mask blank phase defects. A depth-resolved detection of a mask blank defect, either by measuring anti-node peak shift in the EUV-PEEM image under varying inspection wavelength condition or by counting interference fringes with a fixed illumination wavelength, is discussed.
NASA Astrophysics Data System (ADS)
Austermann, J. E.; Aretxaga, I.; Hughes, D. H.; Kang, Y.; Kim, S.; Lowenthal, J. D.; Perera, T. A.; Sanders, D. B.; Scott, K. S.; Scoville, N.; Wilson, G. W.; Yun, M. S.
2009-03-01
We report an overdensity of bright submillimetre galaxies (SMGs) in the 0.15 deg2 AzTEC/COSMOS survey and a spatial correlation between the SMGs and the optical-IR galaxy density at z <~ 1.1. This portion of the COSMOS field shows a ~3σ overdensity of robust SMG detections when compared to a background, or `blank-field', population model that is consistent with SMG surveys of fields with no extragalactic bias. The SMG overdensity is most significant in the number of very bright detections (14 sources with measured fluxes S1.1mm > 6 mJy), which is entirely incompatible with sample variance within our adopted blank-field number densities and infers an overdensity significance of >> 4σ. We find that the overdensity and spatial correlation to optical-IR galaxy density are most consistent with lensing of a background SMG population by foreground mass structures along the line of sight, rather than physical association of the SMGs with the z <~ 1.1 galaxies/clusters. The SMG positions are only weakly correlated with weak-lensing maps, suggesting that the dominant sources of correlation are individual galaxies and the more tenuous structures in the survey region, and not the massive and compact clusters. These results highlight the important roles cosmic variance and large-scale structure can play in the study of SMGs.
NASA Technical Reports Server (NTRS)
Eigenbrode, J. L.; Glavin, D.; Coll, P.; Summons, R. E.; Mahaffy, P.; Archer, D.; Brunner, A.; Conrad, P.; Freissinet, C.; Martin, M.;
2013-01-01
key challenge in assessing the habitability of martian environments is the detection of organic matter - a requirement of all life as we know it. The Curiosity rover, which landed on August 6, 2012 in Gale Crater of Mars, includes the Sample Analysis at Mars (SAM) instrument suite capable of in situ analysis of gaseous organic components thermally evolved from sediment samples collected, sieved, and delivered by the MSL rover. On Sol 94, SAM received its first solid sample: scooped sediment from Rocknest that was sieved to <150 m particle size. Multiple 10-40 mg portions of the scoop #5 sample were delivered to SAM for analyses. Prior to their introduction, a blank (empty cup) analysis was performed. This blank served 1) to clean the analytical instrument of SAMinternal materials that accumulated in the gas processing system since integration into the rover, and 2) to characterize the background signatures of SAM. Both the blank and the Rocknest samples showed the presence of hydrocarbon components.
Rejection of atrial sensing artifacts by a pacing lead with short tip-to-ring spacing.
Nash, A; Fröhlig, G; Taborsky, M; Stammwitz, E; Maru, F; Bouwens, L H M; Celiker, C
2005-01-01
The ability of a new pacing lead design, with a 10 mm tip-to-ring spacing, to facilitate rejection of sensed far field R-waves and myopotentials was evaluated. Measurements were performed in 66 patients. The occurrence of far field R-wave sensing and myopotential sensing was determined by means of the surface ECG and the ECG markers provided by the pacemaker. At an atrial sensitivity of 0.25 mV and an atrial blanking of 50 ms far field R-wave sensing was observed in 12 patients (18.2%) and at an atrial sensitivity of 1.0 mV no far-field R-wave sensing was observed. Myopotentials were sensed in 3 patients. In all patients the measured P-wave amplitude was at least twice the estimated amplitude of the far field R-wave at an atrial blanking of 50 ms. The results from this study show that a small tip-to-ring spacing allows for programming of a high atrial sensitivity and short atrial blanking with an acceptably low risk for atrial artifact sensing.
Shelton, Larry R.
1994-01-01
The U.S. Geological Survey's National Water-Quality Assessment program includes extensive data- collection efforts to assess the quality of the Nations's streams. These studies require analyses of stream samples for major ions, nutrients, sediments, and organic contaminants. For the information to be comparable among studies in different parts of the Nation, consistent procedures specifically designed to produce uncontaminated samples for trace analysis in the laboratory are critical. This field guide describes the standard procedures for collecting and processing samples for major ions, nutrients, organic contaminants, sediment, and field analyses of conductivity, pH, alkalinity, and dissolved oxygen. Samples are collected and processed using modified and newly designed equipment made of Teflon to avoid contamination, including nonmetallic samplers (D-77 and DH-81) and a Teflon sample splitter. Field solid-phase extraction procedures developed to process samples for organic constituent analyses produce an extracted sample with stabilized compounds for more accurate results. Improvements to standard operational procedures include the use of processing chambers and capsule filtering systems. A modified collecting and processing procedure for organic carbon is designed to avoid contamination from equipment cleaned with methanol. Quality assurance is maintained by strict collecting and processing procedures, replicate sampling, equipment blank samples, and a rigid cleaning procedure using detergent, hydrochloric acid, and methanol.
Sandlund, Odd Terje; Karlsson, Sten; Thorstad, Eva B; Berg, Ole Kristian; Kent, Matthew P; Norum, Ine C J; Hindar, Kjetil
2014-01-01
The river-resident Salmo salar (“småblank”) has been isolated from other Atlantic salmon populations for 9,500 years in upper River Namsen, Norway. This is the only European Atlantic salmon population accomplishing its entire life cycle in a river. Hydropower development during the last six decades has introduced movement barriers and changed more than 50% of the river habitat to lentic conditions. Based on microsatellites and SNPs, genetic variation within småblank was only about 50% of that in the anadromous Atlantic salmon within the same river. The genetic differentiation (FST) between småblank and the anadromous population was 0.24. This is similar to the differentiation between anadromous Atlantic salmon in Europe and North America. Microsatellite analyses identified three genetic subpopulations within småblank, each with an effective population size Ne of a few hundred individuals. There was no evidence of reduced heterozygosity and allelic richness in contemporary samples (2005–2008) compared with historical samples (1955–56 and 1978–79). However, there was a reduction in genetic differentiation between sampling localities over time. SNP data supported the differentiation of småblank into subpopulations and revealed downstream asymmetric gene flow between subpopulations. In spite of this, genetic variation was not higher in the lower than in the upper areas. The meta-population structure of småblank probably maintains genetic variation better than one panmictic population would do, as long as gene flow among subpopulations is maintained. Småblank is a unique endemic island population of Atlantic salmon. It is in a precarious situation due to a variety of anthropogenic impacts on its restricted habitat area. Thus, maintaining population size and avoiding further habitat fragmentation are important. PMID:24967074
Latysh, Natalie E.; Wetherbee, Gregory A.
2007-01-01
The U.S. Geological Survey (USGS) Branch of Quality Systems operates external quality assurance programs for the National Atmospheric Deposition Program/Mercury Deposition Network (NADP/MDN). Beginning in 2004, three programs have been implemented: the system blank program, the interlaboratory comparison program, and the blind audit program. Each program was designed to measure error contributed by specific components in the data-collection process. The system blank program assesses contamination that may result from sampling equipment, field exposure, and routine handling and processing of the wet-deposition samples. The interlaboratory comparison program evaluates bias and precision of analytical results produced by the Mercury Analytical Laboratory (HAL) for the NADP/MDN, operated by Frontier GeoSciences, Inc. The HAL's performance is compared with the performance of five other laboratories. The blind audit program assesses bias and variability of MDN data produced by the HAL using solutions disguised as environmental samples to ascertain true laboratory performance. This report documents the implementation of quality assurance procedures for the NADP/MDN and the operating procedures for each of the external quality assurance programs conducted by the USGS. The USGS quality assurance information provides a measure of confidence to NADP/MDN data users that measurement variability is distinguished from environmental signals.
Wetherbee, Gregory A.; Martin, RoseAnn
2016-07-05
The Mercury Deposition Network programs include the system blank program and an interlaboratory comparison program. System blank results indicated that maximum total mercury contamination concentrations in samples were less than the third percentile of all Mercury Deposition Network sample concentrations. The Mercury Analytical Laboratory produced chemical concentration results with low bias and variability compared with other domestic and international laboratories that support atmospheric-deposition monitoring.
Field of Gifted Dreams: An Interview with Susan Assouline
ERIC Educational Resources Information Center
Henshon, Suzanna E.
2016-01-01
Susan G. Assouline is the director of the Belin-Blank Center, holds the Myron and Jacqueline N. Blank Endowed Chair in Gifted Education, and is a professor of school psychology. She received her BS in general science with a teaching endorsement, her EdS in school psychology, and her PhD in psychological and quantitative foundations, all from the…
Rapid iconic erasure without masking.
Tijus, Charles Albert; Reeves, Adam
2004-01-01
We report on the erasure of the iconic memory of an array of 12 black letters flashed on a continuously- present white field. Erasure is accomplished by replacing the 16 ms letter array (frame 1) with a blank white frame for 16 ms (frame 2). The letter array returns in frame 3, with from one to six letters missing. Report of the missing letters is accurate without the blank white frame but is impoverished with it, as if interposing the blank erases the icon. Erasure occurs without any obvious luminance masking, 'mud splashes', pattern masking (backward, forward, or metacontrast), lateral masking, or masking by object substitution. Erasure is greatly decreased if the blank is presented one frame earlier or later. We speculate that erasure is due to a rapid reset of the icon produced by an informational mis-match.
Basin F Overburden and Soil Sampling and Analysis Study, Rocky Mountain Arsenal
1982-05-01
boring sites will be es:ablished via standard :and surveyinS procedures. 3.3 Bor-ng/ Samaling Procidures Upon staking/marking of the bore holes, the folloi...procedure until the interferences have been eliminated. 3.2.2 Samale Testing Step OC (6) (Procedure Blank) The procedure blank consists of the
Jian, Yu-Tao; Yang, Yue; Tian, Tian; Stanford, Clark; Zhang, Xin-Ping; Zhao, Ke
2015-01-01
Five types of porous Nickel-Titanium (NiTi) alloy samples of different porosities and pore sizes were fabricated. According to compressive and fracture strengths, three groups of porous NiTi alloy samples underwent further cytocompatibility experiments. Porous NiTi alloys exhibited a lower Young’s modulus (2.0 GPa ~ 0.8 GPa). Both compressive strength (108.8 MPa ~ 56.2 MPa) and fracture strength (64.6 MPa ~ 41.6 MPa) decreased gradually with increasing mean pore size (MPS). Cells grew and spread well on all porous NiTi alloy samples. Cells attached more strongly on control group and blank group than on all porous NiTi alloy samples (p < 0.05). Cell adhesion on porous NiTi alloys was correlated negatively to MPS (277.2 μm ~ 566.5 μm; p < 0.05). More cells proliferated on control group and blank group than on all porous NiTi alloy samples (p < 0.05). Cellular ALP activity on all porous NiTi alloy samples was higher than on control group and blank group (p < 0.05). The porous NiTi alloys with optimized pore size could be a potential orthopedic material. PMID:26047515
Hall, Naima L.; Dvonch, Joseph Timothy; Marsik, Frank J.; Barres, James A.; Landis, Matthew S.
2017-01-01
This paper describes the development of a new artificial turf surrogate surface (ATSS) sampler for use in the measurement of mercury (Hg) dry deposition. In contrast to many existing surrogate surface designs, the ATSS utilizes a three-dimensional deposition surface that may more closely mimic the physical structure of many natural surfaces than traditional flat surrogate surface designs (water, filter, greased Mylar film). The ATSS has been designed to overcome several complicating factors that can impact the integrity of samples with other direct measurement approaches by providing a passive system which can be deployed for both short and extended periods of time (days to weeks), and is not contaminated by precipitation and/or invalidated by strong winds. Performance characteristics including collocated precision, in-field procedural and laboratory blanks were evaluated. The results of these performance evaluations included a mean collocated precision of 9%, low blanks (0.8 ng), high extraction efficiency (97%–103%), and a quantitative matrix spike recovery (100%). PMID:28208603
Rocky Mountain snowpack physical and chemical data for selected sites, 2009
Ingersoll, George P.; Mast, M. Alisa; Swank, James M.; Campbell, Chelsea D.
2010-01-01
The Rocky Mountain Snowpack program established a network of snowpack-sampling sites in the Rocky Mountain region from New Mexico to Montana to monitor the chemical content of snow and to understand the effects of regional atmospheric deposition. The U.S. Geological Survey, in cooperation with the National Park Service; the U.S. Department of Agriculture Forest Service; the Colorado Department of Public Health and Environment; Teton County, Wyoming; and others, collected and analyzed snowpack samples annually for 48 or more sites in the Rocky Mountain region during 1993-2009. Sixty-three snowpack-sampling sites were sampled once each in 2009 and data are presented in this report. Data include acid-neutralization capacity, specific conductance, pH, hydrogen ion concentrations, dissolved concentrations of major constituents (calcium, magnesium, sodium, potassium, ammonium, chloride, sulfate, and nitrate), dissolved organic carbon concentrations, snow-water equivalent, snow depth, total mercury concentrations, and ionic charge balance. Quality-assurance data for field and laboratory blanks and field replicates for 2009 also are included.
Wang, Bronwen; Owens, Victoria; Bailey, Elizabeth; Lee, Greg
2011-01-01
We report on the chemical analysis of water samples collected from the Taylor Mountains 1:250,000- and Dillingham D-4 1:63,360-scale quadrangles, Alaska. Reported parameters include pH, conductivity, water temperature, major cation and anion concentrations, and trace-element concentrations. We collected the samples as part of a multiyear U.S. Geological Survey project entitled "Geologic and Mineral Deposit Data for Alaskan Economic Development." Data presented here are from samples collected in June and August 2008. Minimal interpretation accompanies this data release. This is the fourth release of aqueous geochemical data from this project; data from samples collected in 2004, 2005, and 2006 were published previously. The data in this report augment but do not duplicate or supersede the previous data releases. Site selection was based on a regional sampling strategy that focused on first- and second-order drainages. Water sample sites were selected on the basis of landscape parameters that included physiography, wetland extent, lithological changes, and a cursory field review of mineralogy from pan concentrates. Stream water in the study area is dominated by bicarbonate (HCO3-), although in a few samples more than 50 percent of the anionic charge can be attributed to sulfate (SO42-). The major-cation chemistry of these samples ranges from Ca2+-Mg2+ dominated to a mix of Ca2+-Mg2+-Na++K2+. In most cases, analysis of duplicate samples showed good agreement for the major cation and major anions with the exception of the duplicate samples at site 08TA565. At site 08TA565, Ca, Mg, Cl, and CaCO3 exceeded 25 percent and the concentrations of trace elements As, Fe and Mn also exceeded 25 percent in this duplicate pair. Chloride concentration varied by more than 25 percent in 5 of the 11 duplicated samples. Trace-element concentrations in these samples generally were at or near the detection limit for the method used and, except for Co at site 08TA565, generally good agreement was determined between duplicate samples for elements with detectable concentrations. Major-ion concentrations were below detection limits in all field blanks, and the trace-element concentrations also were generally below detection limits; however, Co, Mn, Na, Zn, Cl, and Hg were detected in one or more field blank samples.
Theoretical Analysis on Mechanical Deformation of Membrane-Based Photomask Blanks
NASA Astrophysics Data System (ADS)
Marumoto, Kenji; Aya, Sunao; Yabe, Hedeki; Okada, Tatsunori; Sumitani, Hiroaki
2012-04-01
Membrane-based photomask is used in proximity X-ray lithography including that in LIGA (Lithographie, Galvanoformung und Abformung) process, and near-field photolithography. In this article, out-of-plane deformation (OPD) and in-plane displacement (IPD) of membrane-based photomask blanks are theoretically analyzed to obtain the mask blanks with flat front surface and low stress absorber film. First, we derived the equations of OPD and IPD for the processing steps of membrane-based photomask such as film deposition, back-etching and bonding, using a theory of symmetrical bending of circular plates with a coaxial circular hole and that of deformation of cylinder under hydrostatic pressure. The validity of the equations was proved by comparing the calculation results with experimental ones. Using these equations, we investigated the relation between the geometry of the mask blanks and the distortions generally, and gave the criterion to attain the flat front surface. Moreover, the absorber stress-bias required to obtain zero-stress on finished mask blanks was also calculated and it has been found that only little stress-bias was required for adequate hole size of support plate.
Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.
2006-01-01
The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance/quality-control data for the time period addressed in this report were stored in the laboratory's SAS data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality- control samples analyzed from July 1997 through June 1999. Results for the quality-control samples for 18 analytical procedures were evaluated for bias and precision. Control charts indicate that data for eight of the analytical procedures were occasionally biased for either high-concentration and (or) low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, total monomeric aluminum, total aluminum, ammonium, calcium, chloride, specific conductance, and sulfate. The data from the potassium and sodium analytical procedures are insufficient for evaluation. Results from the filter-blank and analytical-blank analyses indicate that the procedures for 11 of 13 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. Blank analysis results for chloride showed that 22 percent of blanks did not meet data-quality objectives and results for dissolved organic carbon showed that 31 percent of the blanks did not meet data-quality objectives. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 14 of the 18 analytes. At least 90 percent of the samples met data-quality objectives for all analytes except total aluminum (70 percent of samples met objectives) and potassium (83 percent of samples met objectives). Results of the USGS interlaboratory Standard Reference Sample (SRS) Project indicated good data quality for most constituents over the time period. The P-sample (low-ionic-strength constituents) analysis had good ratings in two of these studies and a satisfactory rating in the third. The results of the T-sample (trace constituents) analysis indicated high data quality with good ratings in all three studies. The N-sample (nutrient constituents) studies had one each of excellent, good, and satisfactory ratings. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 80 percent of the samples met data-quality objectives for 9 of the 13 analytes; the exceptions were dissolved organic carbon, ammonium, chloride, and specific conductance. Data-quality objectives were not met for dissolved organic carbon in two NWRI studies, but all of the samples were within control limits for the last study. Data-quality objectives were not met in 41 percent of samples analyzed for ammonium, 25 percent of samples analyzed for chloride, and 30 percent of samples analyzed for specific conductance. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 84 percent of the samples analyzed for calcium, chloride, magnesium, pH, and potassium. Data-quality objectives were met by 73 percent of those analyzed for sulfate. The data-quality objective was not met for sodium. The data are insufficient for evaluation of the specific conductance results.
Ivahnenko, Tamara; Szabo, Zoltan; Hall, G.S.
1996-01-01
Water samples were collected during 1993 from 22 public supply wells screened in the Kirkwood-Cohansey aquifer system; concentrations of 18 trace elements were determined primarily by using inductively coupled plasma-mass spectrometry (ICP-MS) techniques, though graphite furnace atomic adsorption, hydride generation, and cold- vapor flameless atomic adsorption techniques were used for thallium, arsenic, and mercury, respectively, at the U.S. Geological Survey (USGS) National Water Quality Laboratory (NWQL). In addition, laboratory measurements of alkalinity and turbidity were made. The ground-water samples were collected by using ultra-clean sampling protocols developed by the USGS for collecting ground-water samples in areas with water containing low concentrations of trace elements. This technique is based on recently gained experience in sampling surface water for these elements. Field parameters (water temperature, specific conductance, pH, and dissolved-oxygen concentration) were monitored prior to sample collection. Three equipment blanks were collected to ensure that low-level trace-element contamination did not occur during sample collection. One split sample and a commercially- prepared reference standard were submitted to the NWQL o evaluate laboratory precision and accuracy, respectively. Trace-element concentrations in 10 sample splits and one equipment blank were also determined at the Rutgers University Chemistry Department laboratory. Results of the ICP-MS analyses and cold vapor flameless atomic absorption indicated that five trace elements-- cobalt, copper, lead, mercury, and nickel--were detectable in low concentrations (<0.1-29 mg/L) in most of the samples from the 22 wells, and four elements--aluminum, barium, manganese and zinc--were detected in higher concentrations than the other elements (30-710 mg/L for aluminum; 4-180 mg/L for barium, manganese, and zinc). The remaining nine trace elements were present in concentrations consistently lower than the minimum reporting limit. Turbidity was low (less than 1 nephelometric turbidity unit (NTU)), indicating that the trace-element concentrations were present in the dissolved phase and ideally would be reproducible in the absence of highly variable concentrations of particulates. The concentration of lead in one sample exceeded the U.S. Environmental Protection Agency (USEPA) action level of 15 mg/L; concentrations ranged from <1 to 16 mg/L. Mercury was frequently detected; concentrations ranged from <0.1 to 1.1 mg/L but did not exceed the USEPA maximum contaminant level. Results of analyses of the equipment blanks indicated that samples collected by using the new ultra-clean sampling protocols were free of low-level (< 1mg/L) trace-element contamination. The analysis of the split sample sent to the NWQL had a difference of 5 percent or less for all constituents except aluminum, for which the analysis had a difference of 10 percent. Results of ICP-MS analyses of split water samples sent to the Rutgers University Chemistry Department laboratory were, in general, in good agreement (within 10 percent) with those of the NWQL. Results of the analysis of the commercial standard agreed (within 5 percent) with the known concentrations of the trace elements. The quality-assurance data (three blanks, one split sample, and one standard), although not statistically evaluated because of the small data set, indicate that the measured trace-element concentrations are precise and accurate and that the samples were free of contamination at the microgram-per-liter level of contamination.
Production of the 4.1-m Zerodur mirror blank for the VISTA Telescope
NASA Astrophysics Data System (ADS)
Doehring, Thorsten; Jedamzik, Ralf; Wittmer, Volker; Thomas, Armin
2004-09-01
VISTA (Visible and Infrared Survey Telescope for Astronomy) is designed to be the world's largest wide field telescope. After finishing of the construction the telescope will be part of ESO and located in Chile close to the VLT observatory at Cerro Paranal. In November 2001 SCHOTT was selected by the VISTA project office at the Royal Observatory of Edinburgh to deliver the 4.1 m diameter primary mirror blank. The manufacturing of the mirror blank made from the zero expansion material Zerodur was challenging especially due to the f/1 design. Several tons of the glass ceramic material were removed during the grinding operation. A meniscus blank with a diameter of 4100 mm and a thickness of 171.5 mm was generated, having a large central hole of 1200 mm and an aspherical shape of the concave surface. Also the handling and turning operations needed special effort and were performed by a skilled team. This paper presents details and pictures of the corresponding production and inspection sequence at SCHOTT. The geometrical parameters were measured during manufacturing by help of a laser tracker system and the achieved parameters were compared with the initial technical specification. The final quality inspection verified the excellent quality of the mirror blank. The close co-operation between the astronomers and industry resulted in a project management without problems. In April 2003 the VISTA blank was delivered successfully within a ceremony dedicated to the anniversary of "100 years of astronomical mirror blanks from SCHOTT."
Guided episodic sampling for capturing and characterizing industrial plumes
NASA Astrophysics Data System (ADS)
Ou-Yang, Chang-Feng; Liao, Wei-Cheng; Chang, Chih-Chung; Hsieh, Hsin-Cheng; Wang, Jia-Lin
2018-02-01
An integrated sampling technique, dubbed trigger sampling, was developed to capture characteristic industrial emissions or plumes. In the field experiment, a hydrogen sulfide (H2S) analyzer was used as the triggering instrument at the boundary of a refinery plant due to frequent complaints of foul smell from local residents. Ten episodic samples were captured when the H2S level surpassed the prescribed trigger level of 8.5 ppbv over a three-day period. Three non-episodic (blank) samples and 23 road-side samples were also collected for comparison. All the 36 flask samples were analyzed by gas chromatography-mass spectrometry/flame ionization detection (GC-MS/FID) for 108 volatile organic compounds (VOCs). The total VOC abundance of the event samples was exceedingly higher than the non-episodic samples by over 80 times in the extreme case. Alkanes were found to be the dominant constituents in the event samples, amounting to over 90% of the total VOC concentrations vs. only 30-40% for the blank and metropolitan samples. In addition, light alkanes in the event samples were highly correlated with the trigger species H2S (R2 = 0.82), implying their common origin. The matrix of chemical composition vs. sample types permitted easy visualization of the dominance of light alkanes for the event samples compared to other types of samples. Principle component analysis (PCA) identified two major contributors to cover 93% of the total variance arising from the 36 samples, further quantifying the distinction of the triggered episodic samples from the contrast samples. The proposed trigger sampling is a coupling of fast-and-slow measurement techniques. In this example, the fast-response H2S analyzer served to "guide" sampling to capture industrial plumes which were then characterized by a relatively slow method of GC-MS/FID for detailed chemical composition representative of the prominent sources.
Evaluation of a Fluidized-Bed Paint Stripper at Red River Army Depot
1992-04-15
are summarized in Table 3-1. Calibra- tion guidelines are described in more detail in Appendix E. 0 Onsite audits of dry gas meters, thermocouples...experienced laboratory per- sonnel. o Internal and external audits to ensure accuracy in sampling and analysis. o Reagent, filter, and field blanks to...0.0 0.0 If below detection limits, replace 0 with 1. 0 0 0 ?Mn < polutant > mam mg 0.0 0.0 0.0 Co cpoliuLant> concentration gr/dscf 0.000E*00 0.000E.00
Evolution of microbial communities during electrokinetic treatment of antibiotic-polluted soil.
Li, Hongna; Li, Binxu; Zhang, Zhiguo; Zhu, Changxiong; Tian, Yunlong; Ye, Jing
2018-02-01
The evolution of microbial communities during the electrokinetic treatment of antibiotic-polluted soil (EKA) was investigated with chlortetracycline (CTC), oxytetracycline (OTC) and tetracycline (TC) as template antibiotics. The total population of soil microorganisms was less affected during the electrokinetic process, while living anti-CTC, anti-OTC, anti-TC and anti-MIX bacteria were inactivated by 10.48%, 31.37%, 34.76%, and 22.08%, respectively, during the 7-day treatment compared with antibiotic-polluted soil without an electric field (NOE). Accordingly, samples with NOE treatment showed a higher Shannon index than those with EKA treatment, indicating a reduction of the microbial community diversity after electrokinetic processes. The major taxonomic phyla found in the samples of EKA and NOE treatment were Proteobacteria, Bacteroidetes, Firmicutes and Actinobacteria. And the distribution of Actinobacteria, Cyanobacteria, and Chloroflexi was greatly decreased compared with blank soil. In the phylum Proteobacteria, the abundance of Alphaproteobacteria was greatly reduced in the soils supplemented with antibiotics (from 13.40% in blank soil to 6.43-10.16% after treatment); while Betaproteobacteria and Deltaproteobacteria showed a different trend with their abundance increased compared to blank soil, and Gammaproteobacteria remained unchanged for all treatments (2.36-2.78%). The varied trends for different classes indicated that the major bacterial groups changed with the treatments due to their different adaptability to the antibiotics as well as to the electric field. SulI being an exception, the reduction ratio of the observed antibiotic resistance genes (ARGs) including tetC, tetG, tetW, tetM, intI1, and sulII in the 0-2cm soil sampled with EKA versus NOE treatment reached 55.17%, 3.59%, 99.26%, 89.51%, 30.40%, and 27.92%, respectively. Finally, correlation analysis was conducted between antibiotic-resistant bacteria, ARGs and taxonomic bacterial classes. It was found that sulII was the most representative of many different bacteria among the seven ARGs studied. This is the first report on the changes in microbial communities before and after EKA, and the present results demonstrated that the application of EKA is a useful and effective approach to suppressing both antibiotic resistant microorganisms and ARGs. Copyright © 2017 Elsevier Inc. All rights reserved.
Seeing Red and Shooting Blanks: Study of Red Quasars and Blank X-Ray Sources
NASA Technical Reports Server (NTRS)
Oliversen, Ronald (Technical Monitor); Elvis, Martin
2005-01-01
A major paper describing the technique and providing a list of 'blanks' was published in the Astrophysical Journal (abstract below). The results revealed a fascinating trove of novel X-ray sources: high redshift clusters of galaxies found efficiently; X-ray absorbed, optically clean AGN, which may be the bright prototypes of Chandra Deep Survey sources; and several with a still unknown nature. Recent XMM-Newton results confirm the existence of this class of X-ray source with much refined positions. During the first year of this project we have made a major discovery. The second 'blanks' X-ray source observed with Chandra was found to be extended. Using Chandra data and ground-based R and K band imaging we estimated this to be a high redshift cluster of galaxies with z approx. 0.85. Spectroscopy agrees with this estimate (z=0.89). This success shows that our method of hunting down 'blank' field X-ray sources is a highly efficient method of finding the otherwise elusive high redshift clusters. With extensive follow-up we should be able to use 'blanks' to make cosmological tests. The paper is now in press in the Astrophysical Journal (abstract below.) The other Chandra source is point-like, showing that there are a variety of 'blank' source types. Other follow-up observations with XMM-Newton, and (newly approved in cycle 2) with Chandra are eagerly awaited. A follow-up paper uses a large amount of supporting data for the remaining blanks. A combination of ROSAT, Chandra and ground based data convincingly identified one of the blanks as a Ultra-luminous X-ray source (ULX) in a spiral galaxy (abstract below). This program resulted in 3 refereed papers in major journals, 4 conference proceedings and a significant fraction of the PhD thesis of Dr. Ilaria Cagnoni. Details of the publications are given.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barty, A; Mirkarimi, P; Stearns, D G
2002-05-22
EUV mask blanks are fabricated by depositing a reflective Mo/Si multilayer film onto super-polished substrates. Small defects in this thin film coating can significantly alter the reflected field and introduce defects in the printed image. Ideally one would want to produce defect-free mask blanks; however, this may be very difficult to achieve in practice. One practical way to increase the yield of mask blanks is to effectively repair multilayer defects, and to this effect they present two complementary defect repair strategies for use on multilayer-coated EUVL mask blanks. A defect is any area on the mask which causes unwanted variationsmore » in EUV dose in the aerial image obtained in a printing tool, and defect repair is correspondingly defined as any strategy that renders a defect unprintable during exposure. The term defect mitigation can be adopted to describe any strategy which renders a critical defect non-critical when printed, and in this regard a non-critical defect is one that does not adversely affect device function. Defects in the patterned absorber layer consist of regions where metal, typically chrome, is unintentionally added or removed from the pattern leading to errors in the reflected field. There currently exists a mature technology based on ion beam milling and ion beam assisted deposition for repairing defects in the absorber layer of transmission lithography masks, and it is reasonable to expect that this technology will be extended to the repair of absorber defects in EUVL masks. However, techniques designed for the repair of absorber layers can not be directly applied to the repair of defects in the mask blank, and in particular the multilayer film. In this paper they present for the first time a new technique for the repair of amplitude defects as well as recent results on the repair of phase defects.« less
Radon Assessment of Occupational Facilities, Homestead ARB, FL
2013-11-21
electrets is directly measured and used to calculate radon levels. The radon detectors were placed in the test locations for greater than 90 days in...of USAFSAM’s radon analysis. A proficiency test was last performed and passed on 18 July 2012. (2) Blanks: Six field blanks were used during the...voltage. 5. CONCLUSIONS AND RECOMMENDATIONS: a. All 46 facilities tested had radon concentrations below the action limit of 4 pCi/L; no radon
Sagona, Jessica A; Dukett, James E; Hawley, Harmonie A; Mazurek, Monica A
2014-10-03
Cloud water samples from Whiteface Mountain, NY were used to develop a combined sampling and gas chromatography-mass spectrometric (GCMS) protocol for evaluating the complex mixture of highly polar organic compounds (HPOC) present in this atmospheric medium. Specific HPOC of interest were mono- and di keto-acids which are thought to originate from photochemical reactions of volatile unsaturated hydrocarbons from biogenic and manmade emissions and be a major fraction of atmospheric carbon. To measure HPOC mixtures and the individual keto-acids in cloud water, samples first must be derivatized for clean elution and measurement, and second, have low overall background of the target species as validated by GCMS analysis of field and laboratory blanks. Here, we discuss a dual derivatization method with PFBHA and BSTFA which targets only organic compounds that contain functional groups reacting with both reagents. The method also reduced potential contamination by minimizing the amount of sample processing from the field through the GCMS analysis steps. Once derivatized only gas chromatographic separation and selected ion monitoring (SIM) are needed to identify and quantify the polar organic compounds of interest. Concentrations of the detected total keto-acids in individual cloud water samples ranged from 27.8 to 329.3ngmL(-1) (ppb). Method detection limits for the individual HPOC ranged from 0.17 to 4.99ngmL(-1) and the quantification limits for the compounds ranged from 0.57 to 16.64ngmL(-1). The keto-acids were compared to the total organic carbon (TOC) results for the cloud water samples with concentrations of 0.607-3.350mgL(-1) (ppm). GCMS analysis of all samples and blanks indicated good control of the entire collection and analysis steps. Selected ion monitoring by GCMS of target keto-acids was essential for screening the complex organic carbon mixtures present at low ppb levels in cloud water. It was critical for ensuring high levels of quality assurance and quality control and for the correct identification and quantification of key marker compounds. Copyright © 2014 Elsevier B.V. All rights reserved.
Selection of a battery of rapid toxicity sensors for drinking water evaluation.
van der Schalie, William H; James, Ryan R; Gargan, Thomas P
2006-07-15
Comprehensive identification of chemical contaminants in Army field water supplies can be a lengthy process, but rapid analytical methods suitable for field use are limited. A complementary approach is to directly measure toxicity instead of individual chemical constituents. Ten toxicity sensors utilizing enzymes, bacteria, or vertebrate cells were tested to determine the minimum number of sensors that could rapidly identify toxicity in water samples containing one of 12 industrial chemicals. The ideal sensor would respond at a concentration just exceeding the Military Exposure Guideline (MEG) level for the chemical (an estimated threshold for adverse effects) but below the human lethal concentration. Chemical solutions were provided to testing laboratories as blind samples. No sensors responded to deionized water blanks, and only one sensor responded to a hard water blank. No single toxicity sensor responded to more than six chemicals in the desired response range, and one chemical (nicotine) was not detected by any sensor with the desired sensitivity. A combination of three sensors (Microtox, the Electric Cell Substrate Impedance Sensing (ECIS) test, and the Hepatocyte low density lipoprotein (LDL) uptake test) responded appropriately to nine of twelve chemicals. Adding a fourth sensor (neuronal microelectrode array) to the test battery allowed detection of two additional chemicals (aldicarb and methamidophos), but the neuronal microelectrode array was overly sensitive to paraquat. Evaluating sensor performance using a standard set of chemicals and a desired sensitivity range provides a basis both for selecting among available toxicity sensors and for evaluating emerging sensor technologies. Recommendations for future toxicity sensor evaluations are discussed.
Carter, Janet M.; Kingsbury, James A.; Hopple, Jessica A.; Delzer, Gregory C.
2010-01-01
The National Water-Quality Assessment Program of the U.S. Geological Survey began implementing Source Water-Quality Assessments (SWQAs) in 2001 that focus on characterizing the quality of source water and finished water of aquifers and major rivers used by some of the larger community water systems in the United States. As used in SWQA studies, source water is the raw (ambient) water collected at the supply well before water treatment (for groundwater) or the raw (ambient) water collected from the river near the intake (for surface water), and finished water is the water that has been treated and is ready to be delivered to consumers. Finished-water samples are collected before the water enters the distribution system. The primary objective of SWQAs is to determine the occurrence of more than 250 anthropogenic organic compounds in source water used by community water systems, many of which currently are unregulated in drinking water by the U.S. Environmental Protection Agency. A secondary objective is to understand recurrence patterns in source water and determine if these patterns also occur in finished water before distribution. SWQA studies were conducted in two phases for most studies completed by 2005, and in one phase for most studies completed since 2005. Analytical results are reported for a total of 295 different anthropogenic organic compounds monitored in source-water and finished-water samples collected during 2002-10. The 295 compounds were classified according to the following 13 primary use or source groups: (1) disinfection by-products; (2) fumigant-related compounds; (3) fungicides; (4) gasoline hydrocarbons, oxygenates, and oxygenate degradates; (5) herbicides and herbicide degradates; (6) insecticides and insecticide degradates; (7) manufacturing additives; (8) organic synthesis compounds; (9) pavement- and combustion-derived compounds; (10) personal-care and domestic-use products; (11) plant- or animal-derived biochemicals; (12) refrigerants and propellants; and (13) solvents. This report presents the analytical results of source- water samples from 448 community water system wells and 21 surface-water sites. This report also presents the analytical results of finished-water samples from 285 wells and 20 surface-water sites from community water systems. Results of quality-assurance/quality-control samples also are presented including data for equipment blanks, field blanks, source solution blanks, and replicate samples.
The EPIC-MOS Particle-Induced Background Spectra
NASA Technical Reports Server (NTRS)
Kuntz, K. D.; Sowden, S. L.
2007-01-01
In order to analyse diffuse emission that fills the field of view, one must accurately characterize the instrumental backgrounds. For the XMM-Newton EPIC instrument these backgrounds include a temporally variable "quiescent" component. as well as the strongly variable soft proton contamination. We have characterized the spectral and spatial response of the EPIC detectors to these background components and have developed tools to remove these backgrounds from observations. The "quiescent" component was characterized using a combination of the filter-wheel-closed data and a database of unexposed-region data. The soft proton contamination was characterized by differencing images and spectra taken during flared and flare-free intervals. After application of our modeled backgrounds, the differences between independent observations of the same region of "blank sky" are consistent with the statistical uncertainties except when there is clear spectral evidence of solar wind charge exchange emission. Using a large sample of blank sky data, we show that strong magnetospheric SWCX emission requires elevated solar wind fluxes; observations through the densest part of the magnetosheath are not necessarily strongly contaminated with SWCX emission.
Rocky Mountain snowpack physical and chemical data for selected sites, 2010
Ingersoll, George P.; Mast, M. Alisa; Swank, James M.; Campbell, Chelsea D.
2010-01-01
The Rocky Mountain Snowpack program established a network of snowpack-sampling sites in the Rocky Mountain region, from New Mexico to Montana, to monitor the chemical content of snow and to understand the effects of regional atmospheric deposition on freshwater systems. Scientists with the U.S. Geological Survey, in cooperation with the National Park Service; the U.S. Department of Agriculture Forest Service; the Colorado Department of Public Health and Environment; Teton County, Wyoming; and others, annually collected and analyzed snow-pack samples at 48 or more sites in the Rocky Mountain region during 1993-2010. Sixty-three snowpack-sampling sites were each sampled once in 2010, and those data are presented in this report. Data include acid-neutralization capacity, specific conductance, pH, hydrogen ion concentrations, dissolved concentrations of major constituents (calcium, magnesium, sodium, potassium, ammonium, chloride, sulfate, and nitrate), dissolved organic carbon concentrations, snow-water equivalent, snow depth, total mercury concentrations, and ionic charge balance. Quality-assurance data for field and laboratory blanks and field replicates for 2010 also are included.
Rocky Mountain Snowpack Physical and Chemical Data for Selected Sites, 1993-2008
Ingersoll, George P.; Mast, M. Alisa; Campbell, Donald H.; Clow, David W.; Nanus, Leora; Turk, John T.
2009-01-01
The Rocky Mountain Snowpack program established a network of snowpack-sampling sites in the Rocky Mountain region from New Mexico to Montana to monitor the chemical content of snow to help in the understanding of the effects of atmospheric deposition to this region. The U.S. Geological Survey, in cooperation with the National Park Service, the USDA Forest Service, Teton County in Wyoming, Rio Blanco County in Colorado, Pitkin County in Colorado, and others, collected and analyzed snowpack samples annually for 48 or more sites in the Rocky Mountain region during 1993-2008. Forty-eight of the 162 snow-sampling sites have been sampled annually since 1993. Data include acid-neutralization capacity, specific conductance, pH, hydrogen ion concentrations, dissolved concentrations of major constituents (calcium, magnesium, sodium, potassium, ammonium, chloride, sulfate, and nitrate), dissolved organic carbon concentrations, snow/ water equivalent, snow depth, stable sulfur isotope ratios, total mercury concentrations (beginning in 2001), and ionic charge balance. Quality-assurance data for field and laboratory blanks and field replicates for individual years (1993-2008) also are included.
Wetherbee, Gregory A.; Martin, RoseAnn
2018-06-29
The U.S. Geological Survey Precipitation Chemistry Quality Assurance project operated five distinct programs to provide external quality assurance monitoring for the National Atmospheric Deposition Program’s (NADP) National Trends Network and Mercury Deposition Network during 2015–16. The National Trends Network programs include (1) a field audit program to evaluate sample contamination and stability, (2) an interlaboratory comparison program to evaluate analytical laboratory performance, and (3) a colocated sampler program to evaluate bias and variability attributed to automated precipitation samplers. The Mercury Deposition Network programs include the (4) system blank program and (5) an interlaboratory comparison program. The results indicate that NADP data continue to be of sufficient quality for the analysis of spatial distributions and time trends for chemical constituents in wet deposition.The field audit program results indicate increased sample contamination for calcium, magnesium, and potassium relative to 2010 levels, and slight fluctuation in sodium contamination. Nitrate contamination levels dropped slightly during 2014–16, and chloride contamination leveled off between 2007 and 2016. Sulfate contamination is similar to the 2000 level. Hydrogen ion contamination has steadily decreased since 2012. Losses of ammonium and nitrate resulting from potential sample instability were negligible.The NADP Central Analytical Laboratory produced interlaboratory comparison results with low bias and variability compared to other domestic and international laboratories that support atmospheric deposition monitoring. Significant absolute bias above the magnitudes of the detection limits was observed for nitrate and sulfate concentrations, but no analyte determinations exceeded the detection limits for blanks.Colocated sampler program results from dissimilar colocated collectors indicate that the retrofit of the National Trends Network with N-CON Systems Company, Inc. precipitation collectors could cause substantial shifts in NADP annual deposition (concentration multiplied by depth) values. Median weekly relative percent differences for analyte concentrations ranged from -4 to +76 percent for cations, from 5 to 6 percent for ammonium, from +14 to +25 percent for anions, and from -21 to +8 percent for hydrogen ion contamination. By comparison, weekly absolute concentration differences for paired identical N-CON Systems Company, Inc., collectors ranged from 4–22 percent for cations; 2–9 percent for anions; 4–5 percent for ammonium; and 13–14 percent for hydrogen ion contamination. The N-CON Systems Company, Inc. collector caught more precipitation than the Aerochem Metrics Model 301 collector (ACM) at the WA99/99WA sites, but it typically caught slightly less precipitation than the ACM at ND11/11ND, sites which receive more wind and snow than WA99/99WA.Paired, identical OTT Pluvio-2 and ETI Noah IV precipitation gages were operated at the same sites. Median absolute percent differences for daily measured precipitation depths ranged from 0 to 7 percent. Annual absolute differences ranged from 0.08 percent (ETI Noah IV precipitation gages) to 11 percent (OTT Pluvio-2 precipitation gages).The Mercury Deposition Network programs include the system blank program and an interlaboratory comparison program. System blank results indicate that maximum total mercury contamination concentrations in samples were less than the third percentile of all Mercury Deposition Network sample concentrations (1.098 nanograms per liter; ng/L). The Mercury Analytical Laboratory produced chemical concentration results with low bias and variability compared with other domestic and international laboratories that support atmospheric-deposition monitoring. The laboratory’s performance results indicate a +1-ng/L shift in bias between 2015 (-0.4 ng/L) and 2016 (+0.5 ng/L).
Bizzi, Cezar A; Cruz, Sandra M; Schmidt, Lucas; Burrow, Robert A; Barin, Juliano S; Paniz, Jose N G; Flores, Erico M M
2018-04-03
A new method for analytical applications based on the Maxwell-Wagner effect is proposed. Considering the interaction of carbonaceous materials with an electromagnetic field in the microwave frequency range, a very fast heating is observed due to interfacial polarization that results in localized microplasma formation. Such effect was evaluated in this work using a monomode microwave system, and temperature was recorded using an infrared camera. For analytical applications, a closed reactor under oxygen pressure was evaluated. The combination of high temperature and oxidant atmosphere resulted in a very effective self-ignition reaction of sample, allowing its use as sample preparation procedure for further elemental analysis. After optimization, a high sample mass (up to 600 mg of coal and graphite) was efficiently digested using only 4 mol L -1 HNO 3 as absorbing solution. Several elements (Ba, Ca, Fe, K, Li, Mg, Na, and Zn) were determined by inductively coupled plasma optical emission spectrometry (ICP-OES). Accuracy was evaluated by using a certified reference material (NIST 1632b). Blanks were negligible, and only a diluted solution was required for analytes absorption preventing residue generation and making the proposed method in agreement with green chemistry recommendations. The feasibility of the proposed method for hard-to-digest materials, the minimization of reagent consumption, and the possibility of multi elemental analysis with lower blanks and better limits of detection can be considered as the main advantages of this method.
Fernandes, Ângela; Barros, Lillian; Martins, Anabela; Herbert, Paulo; Ferreira, Isabel C F R
2015-02-15
Pleurotus ostreatus (Jacq. ex Fr.) P. Kumm. is the third most produced edible mushroom worldwide, due to its ability to colonise and degrade a large variety of lignocellulosic substrates. Therefore, the objective of this work was to evaluate the chemical composition of fruiting bodies of P. ostreatus grown on blank and printed paper substrates, in comparison with samples grown on oat straw (control). The nutritional properties of the control sample were similar to values reported in the literature, while the chemical composition of the samples obtained using paper scraps, either blank or printed, was highly satisfactory. The results obtained validated the nutritional characteristics of the samples, highlighting a profitable means to recycle paper. Copyright © 2014 Elsevier Ltd. All rights reserved.
ZERODUR thermo-mechanical modelling and advanced dilatometry for the ELT generation
NASA Astrophysics Data System (ADS)
Jedamzik, Ralf; Kunisch, Clemens; Westerhoff, Thomas
2016-07-01
Large amounts of low thermal expansion material are required for the upcoming ELT projects. The main mirror is designed using several hundreds of hexagonal 1.4 m sized mirror blanks. The M2 and M3 are monolithic 4 m class mirror blanks. The mirror blank material needs to fulfill tight requirements regarding CTE specification and homogeneity. Additionally the mirror blanks need to be dimensionally stable for more than 30 years. In particular, stress effects due to the changes in the environment shall not entail shape variation of more than 0.5 μm PV within 30 years. In 2010 SCHOTT developed a physically based model to describe the thermal and mechanical long time behavior of ZERODUR. The model enables simulation of the long time behavior of ZERODUR mirror blanks under realistic mechanical and thermal constraints. This presentation shows FEM simulation results on the long time behavior of the ELT M1, M2 and M3 mirror blanks under different loading conditions. Additionally the model results will be compared to an already 15 years lasting long time measurement of a ZERODUR sample at the German federal physical standardization institute (PTB). In recent years SCHOTT pushed the push rod dilatometer measurement technology to its limit. With the new Advanced Dilatometer CTE measurement accuracies of +- 3 ppb/K and reproducibilities of better 1 ppb/K have been achieved. The new Advanced Dilatometer exhibits excellent long time stability.
Moscow Test Well, INEL Oversight Program: Aqueous geochemistry
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCurry, M.; Fromm, J.; Welhan, J.
1992-09-29
This report presents a summary and interpretation of data gathered during sampling of the Moscow Test Well at Moscow, Idaho during April and May of 1992. The principal objectives of this chemical survey were to validate sampling procedures with a new straddle packer sampling tool in a previously hydrologically well characterized and simple sampling environment, and to compare analytical results from two independent labs for reproducibility of analytical results. Analytes included a wide range of metals, anions, nutrients, BNA`s, and VOC`s. Secondary objectives included analyzing of waters from a large distilled water tank (utilized for all field laboratory purposes asmore » ``pure`` stock water), of water which passed through a steamer used to clean the packer, and of rinsates from the packer tool itself before it was lowered into the test well. Analyses were also obtained of blanks and spikes for data validation purposes.« less
Investigation of Tank 241-AW-104 Composite Floating Layer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meznarich, H. K.; Bolling, S. D.; Lachut, J. S.
Seven grab samples and one field blank were taken from Tank 241-AW-104 (AW-104) on June 2, 2017, and received at 222-S Laboratory on June 5, 2017. A visible layer with brown solids was observed floating on the top of two surface tank waste samples (4AW-17-02 and 4AW 17 02DUP). The floating layer from both samples was collected, composited, and submitted for chemical analyses and solid phase characterization in order to understand the composition of the floating layer. Tributyl phosphate and tridecane were higher in the floating layer than in the aqueous phase. Density in the floating layer was slightly lowermore » than the mean density of all grab samples. Sodium nitrate and sodium carbonate were major components with a trace of gibbsite and very small size agglomerates were present in the solids of the floating layer. The supernate consisted of organics, soluble salt, and particulates.« less
NASA Astrophysics Data System (ADS)
Turan, Cabir; Cora, Ömer Necati; Koç, Muammer
2013-12-01
In this study, results of an investigation on the effects of manufacturing and coating process sequence on the contact resistance (ICR) of metallic bipolar plates (BPP) for polymer electrolyte membrane fuel cells (PEMFCs) are presented. Firstly, uncoated stainless steel 316L blanks were formed into BPP through hydroforming and stamping processes. Then, these formed BPP samples were coated with three different PVD coatings (CrN, TiN and ZrN) at three different thicknesses (0.1, 0.5 and 1 μm). Secondly, blanks of the same alloy were coated first with the same coatings, thickness and technique; then, they were formed into BPPs of the same shape and dimensions using the manufacturing methods as in the first group. Finally, these two groups of BPP samples were tested for their ICR to reveal the effect of process sequence. ICR tests were also conducted on the BPP plates both before and after exposure to corrosion to disclose the effect of corrosion on ICR. Coated-then-formed BPP samples exhibited similar or even better ICR performance than formed-then-coated BPP samples. Thus, manufacturing of coated blanks can be concluded to be more favorable and worth further investigation in quest of making cost effective BPPs for mass production of PEMFC.
An Artificial Turf-Based Surrogate Surface Collector for the ...
This paper describes the development of a new artificial turf surrogate surface (ATSS) sampler for use in the measurement of mercury (Hg) dry deposition. In contrast to many existing surrogate surface designs, the ATSS utilizes a three-dimensional deposition surface that may more closely mimic the physical structure of many natural surfaces than traditional flat surrogate surface designs (water, filter, greased Mylar film). The ATSS has been designed to overcome several complicating factors that can impact the integrity of samples with other direct measurement approaches by providing a passive system which can be deployed for both short and extended periods of time (days to weeks), and is not contaminated by precipitation and/or invalidated by strong winds. Performance characteristics including collocated precision, in-field procedural and laboratory blanks were evaluated. The results of these performance evaluations included a mean collocated precision of 9%, low blanks (0.8 ng), high extraction efficiency (97%–103%), and a quantitative matrix spike recovery (100%). In recent years, a growing number of intensive field campaigns and routine measurement networks have provided valuable information on the rates of total mercury (Hg) wet deposition in North America (Guentzel et al., 1995; Rea et al., 1996; Dvonch et al., 1999; Landis and Keeler, 2002; Dvonch et al., 2005; Hall et al., 2005; Keeler et al., 2005; Keeler et al., 2006; Butler et al., 2008; Prestbo an
Code of Federal Regulations, 2012 CFR
2012-04-01
... 803 and recorded in the columns. Blank lines are provided in section L for any additional settlement... recipients of the settlement charges in section L and the names of the recipients of adjustments described in... Borrower's transaction may be left blank on the copy of the HUD-1 which will be furnished to the Seller...
NASA Astrophysics Data System (ADS)
Lotz, Jennifer; Mountain, M.; Grogin, N. A.; Koekemoer, A. M.; Capak, P. L.; Mack, J.; Coe, D. A.; Barker, E. A.; Adler, D. S.; Avila, R. J.; Anderson, J.; Casertano, S.; Christian, C. A.; Gonzaga, S.; Ferguson, H. C.; Fruchter, A. S.; Jenkner, H.; Jordan, I. J.; Hammer, D.; Hilbert, B.; Lawton, B. L.; Lee, J. C.; Lucas, R. A.; MacKenty, J. W.; Mutchler, M. J.; Ogaz, S.; Reid, I. N.; Royle, P.; Robberto, M.; Sembach, K.; Smith, L. J.; Sokol, J.; Surace, J. A.; Taylor, D.; Tumlinson, J.; Viana, A.; Williams, R. E.; Workman, W.
2014-01-01
Using Director's Discretionary observing time, HST is undertaking a revolutionary deep field observing program to peer deeper into the Universe than ever before. The Frontier Fields will combine the power of HST with the natural gravitational telescopes of high-magnification clusters of galaxies to produce the deepest observations of clusters and their lensed galaxies and the second-deepest observations of blank fields ever obtained. Up to six strong-lensing clusters (Abell 2744, MACSJ0416.1-2403, MACSJ0717.5+3745, MACSJ1149.5+2223, AbellS1063, and Abell 370) will be targeted with coordinated parallels of adjacent blank fields with ACS/WFC and WFC3/IR cameras to ~29th ABmag depths in seven bandpasses over the next three years. These observations will reveal distant galaxy populations ~10-100 times fainter than any previously observed, and improve our statistical understanding of galaxies during the epoch of reionization. Here we present Hubble Space Telescope observations of the first set of the Frontier Fields, Abell 2744, and describe the HST Frontier Fields observing strategy and schedule. All data for this observing program is nonproprietary and available immediately upon entry into the Mikulski Archive for Space Telescopes.
Microbial Groundwater Sampling Protocol for Fecal-Rich Environments
Harter, Thomas; Watanabe, Naoko; Li, Xunde; Atwill, Edward R; Samuels, William
2014-01-01
Inherently, confined animal farming operations (CAFOs) and other intense fecal-rich environments are potential sources of groundwater contamination by enteric pathogens. The ubiquity of microbial matter poses unique technical challenges in addition to economic constraints when sampling wells in such environments. In this paper, we evaluate a groundwater sampling protocol that relies on extended purging with a portable submersible stainless steel pump and Teflon® tubing as an alternative to equipment sterilization. The protocol allows for collecting a large number of samples quickly, relatively inexpensively, and under field conditions with limited access to capacity for sterilizing equipment. The protocol is tested on CAFO monitoring wells and considers three cross-contamination sources: equipment, wellbore, and ambient air. For the assessment, we use Enterococcus, a ubiquitous fecal indicator bacterium (FIB), in laboratory and field tests with spiked and blank samples, and in an extensive, multi-year field sampling campaign on 17 wells within 2 CAFOs. The assessment shows that extended purging can successfully control for equipment cross-contamination, but also controls for significant contamination of the well-head, within the well casing and within the immediate aquifer vicinity of the well-screen. Importantly, our tests further indicate that Enterococcus is frequently entrained in water samples when exposed to ambient air at a CAFO during sample collection. Wellbore and air contamination pose separate challenges in the design of groundwater monitoring strategies on CAFOs that are not addressed by equipment sterilization, but require adequate QA/QC procedures and can be addressed by the proposed sampling strategy. PMID:24903186
Performance evaluation of a tailor-made passive sampler for monitoring of tropospheric ozone.
Ozden, Ozlem; Döğeroğlu, Tuncay
2012-09-01
This study presents the performance evaluation of a tailor-made passive sampler developed for the monitoring of tropospheric ozone. The performance of the passive sampler was tested in the field conditions in terms of accuracy, precision, blank values, detection limit, effects of some parameters such as sampling site characteristics and sampling period on the field blanks, self-consistency, experimental and theoretical uptake rates, shelf life and comparison with commercial passive samplers. There was an agreement (R (2) = 0.84) between the responses of passive sampler and the continuous automatic analyser. The accuracy of the sampler, expressed as percent relative error, was obtained lower than 15%. Method precision in terms of coefficient of variance for three simultaneously applied passive samplers was 12%. Sampler detection limit was 2.42 μg m(-3) for an exposure period of 1 week, and the sampler can be stored safely for a period of up to 8 weeks before exposure. Satisfactory self-consistency results showed that extended periods gave the same integrated response as a series of short-term samplers run side by side. The uptake rate of ozone was found to be 10.21 mL min(-1) in a very good agreement with the theoretical uptake rate (10.32 mL min(-1)). The results of the comparison study conducted against a commercially available diffusion tube (Gradko diffusion tube) showed a good linear relationship (R (2) = 0.93) between two passive samplers. The sampler seems suitable to be used in large-scale measurements of ozone where no data are available or the number of existing automated monitors is not sufficient.
NASA Astrophysics Data System (ADS)
Jahnke, Annika; Barber, Jonathan L.; Jones, Kevin C.; Temme, Christian
A method intercomparison study of analytical methods for the determination of neutral, volatile polyfluorinated alkyl substances (PFAS) was carried out in March, 2006. Environmental air samples were collected in triplicate at the European background site Mace Head on the west coast of Ireland, a site dominated by 'clean' westerly winds coming across the Atlantic. Extraction and analysis were performed at two laboratories active in PFAS research using their in-house methods. Airborne polyfluorinated telomer alcohols (FTOHs), fluorooctane sulfonamides and sulfonamidoethanols (FOSAs/FOSEs) as well as additional polyfluorinated compounds were investigated. Different native and isotope-labelled internal standards (IS) were applied at various steps in the analytical procedure to evaluate the different quantification strategies. Field blanks revealed no major blank problems. European background concentrations observed at Mace Head were found to be in a similar range to Arctic data reported in the literature. Due to trace-levels at the remote site, only FTOH data sets were complete and could therefore be compared between the laboratories. Additionally, FOSEs could partly be included. Data comparison revealed that despite the challenges inherent in analysis of airborne PFAS and the low concentrations, all methods applied in this study obtained similar results. However, application of isotope-labelled IS early in the analytical procedure leads to more precise results and is therefore recommended.
Rockwell, Gerald L.; Honeywell, Paul D.
2004-01-01
The U.S. Geological Survey, in cooperation with the California Regional Water Quality Control Board, Lahonton Region, carried out a water-quality data collection program of selected streams in and near Bridgeport Valley, California, during April 2000 to June 2003. These data were collected to provide information used by the California Regional Water Quality Control Board to develop total maximum daily load standards. Field measurements of streamflow, barometric pressure, dissolved oxygen, pH, specific conductance, and water temperature were made at 15 sites located on 6 streams. Water samples were analyzed for nutrients, major ions, turbidity, fecal coliform, fecal streptococci, and suspended sediment. Field data, turbidity, nutrient, major ion, and sediment concentrations and fecal coliform and fecal streptococci densities are given in tables for each site. Field blank data are also presented in a table.
Wheeler, Amanda J; Xu, Xiaohong; Kulka, Ryan; You, Hongyu; Wallace, Lance; Mallach, Gary; Van Ryswyk, Keith; MacNeill, Morgan; Kearney, Jill; Rasmussen, Pat E; Dabek-Zlotorzynska, Ewa; Wang, Daniel; Poon, Raymond; Williams, Ron; Stocco, Corinne; Anastassopoulos, Angelos; Miller, J David; Dales, Robert; Brook, Jeffrey R
2011-03-01
The Windsor, Ontario Exposure Assessment Study evaluated the contribution of ambient air pollutants to personal and indoor exposures of adults and asthmatic children living in Windsor, Ontario, Canada. In addition, the role of personal, indoor, and outdoor air pollution exposures upon asthmatic children's respiratory health was assessed. Several active and passive sampling methods were applied, or adapted, for personal, indoor, and outdoor residential monitoring of nitrogen dioxide, volatile organic compounds, particulate matter (PM; PM-2.5 pm [PM2.5] and < or =10 microm [PM10] in aerodynamic diameter), elemental carbon, ultrafine particles, ozone, air exchange rates, allergens in settled dust, and particulate-associated metals. Participants completed five consecutive days of monitoring during the winter and summer of 2005 and 2006. During 2006, in addition to undertaking the air pollution measurements, asthmatic children completed respiratory health measurements (including peak flow meter tests and exhaled breath condensate) and tracked respiratory symptoms in a diary. Extensive quality assurance and quality control steps were implemented, including the collocation of instruments at the National Air Pollution Surveillance site operated by Environment Canada and at the Michigan Department of Environmental Quality site in Allen Park, Detroit, MI. During field sampling, duplicate and blank samples were also completed and these data are reported. In total, 50 adults and 51 asthmatic children were recruited to participate, resulting in 922 participant days of data. When comparing the methods used in the study with standard reference methods, field blanks were low and bias was acceptable, with most methods being within 20% of reference methods. Duplicates were typically within less than 10% of each other, indicating that study results can be used with confidence. This paper covers study design, recruitment, methodology, time activity diary, surveys, and quality assurance and control results for the different methods used.
NASA Astrophysics Data System (ADS)
Cassano, J. J.; Seefeldt, M. W.; Palo, S.; Knuth, S. L.; Bradley, A. C.; Herrman, P. D.; Kernebone, P. A.; Logan, N. J.
2015-12-01
In September 2012 five Aerosonde unmanned aircraft were used to make measurements of the atmospheric state over the Terra Nova Bay polynya, Antarctica, to explore the details of air - sea ice - ocean coupling. A total of 14 flights were completed in September 2012. Ten of the flight missions consisted of two unmanned aircraft systems (UAS) sampling the atmosphere over Terra Nova Bay on five different days, with one UAS focusing on the downwind evolution of the air mass and a second UAS flying transects roughly perpendicular to the low level winds. The data from these coordinated UAS flights provide a comprehensive three-dimensional data set of the atmospheric state (air temperature, humidity, pressure, and wind) and surface skin temperature over Terra Nova Bay. The remaining UAS flights during the September 2012 field campaign included two local flights near McMurdo Station for flight testing, a single UAS flight to Terra Nova Bay, and a single UAS flight over the Ross Ice Shelf and Ross Sea polynya. A dataset containing the atmospheric and surface data as well as operational aircraft data has been submitted to the United States Antarctic Program Data Coordination Center (USAP-DCC, http://www.usap-data.org/) for free access (http://gcmd.nasa.gov/getdif.htm?NSF-ANT10-43657, doi:10.15784/600125).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wold, Isak G. B.; Barger, Amy J.; Owen, Frazer N.
We present 1.4 GHz catalogs for the cluster fields A370 and A2390 observed with the Very Large Array. These are two of the deepest radio images of cluster fields ever taken. The A370 image covers an area of 40' Multiplication-Sign 40' with a synthesized beam of {approx}1.''7 and a noise level of {approx}5.7 {mu}Jy near the field center. The A2390 image covers an area of 34' Multiplication-Sign 34' with a synthesized beam of {approx}1.''4 and a noise level of {approx}5.6 {mu}Jy near the field center. We catalog 200 redshifts for the A370 field. We construct differential number counts for themore » central regions (radius < 16') of both clusters. We find that the faint (S{sub 1.4{sub GHz}} < 3 mJy) counts of A370 are roughly consistent with the highest blank field number counts, while the faint number counts of A2390 are roughly consistent with the lowest blank field number counts. Our analyses indicate that the number counts are primarily from field radio galaxies. We suggest that the disagreement of our number counts can be largely attributed to cosmic variance.« less
A WISE Selection of MIR AGN in Different Environments
NASA Astrophysics Data System (ADS)
Cheeseboro, Belinda D.; Norman, Dara J.
2015-01-01
This study was undertaken to understand the role of large scale environment in the evolution of MIR-selected AGN. In this study we examine AGN candidates in two types of environments: 7 clusters and 6 blank fields. Two types of clusters were studied in this project: 3 virialized and 4 non-virialized. The redshift of the clusters ranged 0.22≤z≤0.28. We used the mid-infrared WISE All-Sky database to identify AGN, applying various methods to refine our AGN candidate selection. To ascertain if there is an excess or deficit of MIR AGN in galaxy clusters vs. blank fields, we compared the AGN candidate distributions in virialized vs. non-virialized clusters to the blank fields. After close examination and comparison of the results to X-ray selected AGN from the Gilmour et al. (2009) study, we concluded that we do not detect an excess or deficit of MIR AGN in our clusters whether the cluster was virialized or non-virialized. This contrasted the conclusion of the Gilmour et al. (2009) study where there was an excess of X-Ray selected AGN in clusters.We also note an interesting feature in our WISE color-color plots that might be used for further investigation.Cheeseboro was supported by the NOAO/KPNO ResearchExperiences for Undergraduates (REU) Program which is funded by theNational Science Foundation Research Experiences for UndergraduatesProgram (AST-1262829).
... inhalants on the rump. Leave this field blank Marijuana Question 1 Tetrahydrocannabinol is: Question 1: Options * A high tech gasoline A chemical in marijuana A brain neurotransmitter A dinosaur in Jurassic Park ...
Wegner, S.J.
1989-01-01
Multiple water samples from 115 wells and 3 surface water sites were collected between 1980 and 1988 for the ongoing quality assurance program at the Idaho National Engineering Laboratory. The reported results from the six laboratories involved were analyzed for agreement using descriptive statistics. The constituents and properties included: tritium, plutonium-238, plutonium-239, -240 (undivided), strontium-90, americium-241, cesium-137, total dissolved chromium, selected dissolved trace metals, sodium, chloride, nitrate, selected purgeable organic compounds, and specific conductance. Agreement could not be calculated for purgeable organic compounds, trace metals, some nitrates and blank sample analyses because analytical uncertainties were not consistently reported. However, differences between results for most of these data were calculated. The blank samples were not analyzed for differences. The laboratory results analyzed using descriptive statistics showed a median agreement between all useable data pairs of 95%. (USGS)
Wetherbee, Gregory A.; Martin, RoseAnn
2017-02-06
The U.S. Geological Survey Branch of Quality Systems operates the Precipitation Chemistry Quality Assurance Project (PCQA) for the National Atmospheric Deposition Program/National Trends Network (NADP/NTN) and National Atmospheric Deposition Program/Mercury Deposition Network (NADP/MDN). Since 1978, various programs have been implemented by the PCQA to estimate data variability and bias contributed by changing protocols, equipment, and sample submission schemes within NADP networks. These programs independently measure the field and laboratory components which contribute to the overall variability of NADP wet-deposition chemistry and precipitation depth measurements. The PCQA evaluates the quality of analyte-specific chemical analyses from the two, currently (2016) contracted NADP laboratories, Central Analytical Laboratory and Mercury Analytical Laboratory, by comparing laboratory performance among participating national and international laboratories. Sample contamination and stability are evaluated for NTN and MDN by using externally field-processed blank samples provided by the Branch of Quality Systems. A colocated sampler program evaluates the overall variability of NTN measurements and bias between dissimilar precipitation gages and sample collectors.This report documents historical PCQA operations and general procedures for each of the external quality-assurance programs from 2007 to 2016.
Microstructural analysis of hot press formed 22MnB5 steel
NASA Astrophysics Data System (ADS)
Aziz, Nuraini; Aqida, Syarifah Nur; Ismail, Izwan
2017-10-01
This paper presents a microstructural study on hot press formed 22MnB5 steel for enhanced mechanical properties. Hot press forming process consists of simultaneous forming and quenching of heated blank. The 22MnB5 steel was processed at three different parameter settings: quenching time, water temperature and water flow rate. 22MnB5 was processed using 33 full factorial design of experiment (DOE). The full factorial DOE was designed using three factors of quenching time, water temperature and water flow rate at three levels. The factors level were quenching time range of 5 - 11 s, water temperature; 5 - 27°C and water flow rate; 20 - 40 L/min. The as-received and hot press forming processed steel was characterised for metallographic study and martensitic structure area percentage using JEOL Field Emission Scanning Electron Microscopic (FESEM). From the experimental finding, the hot press formed 22MnB5 steel consisted of 50 to 84% martensitic structure area. The minimum quenching time of 8 seconds was required to obtain formed sample with high percentage of martensite. These findings contribute to initial design of processing parameters in hot press forming of 22MnB5 steel blanks for automotive component.
NASA Astrophysics Data System (ADS)
Kenig, F. P. H.; Chou, L.; McKay, C.; Jackson, W. A.; Doran, P. T.; Murray, A. E.; Fritsen, C. H.
2015-12-01
A cold (-13.4 °C), saline (188 psu) evaporative brine is encapsulated in the thick (> 27 m) ice of Lake Vida (McMurdo Dry Valleys, Antarctica). The Lake Vida brine (LVBr), which contains abundant dissolved organic carbon (48.2 mmol/L), support an active but slow microbial community. LVBr contains oxychlorines with 50 μg/L of perchlorate and 11 μg/L of chlorate. The McMurdo Dry Valleys have often been considered as a good Mars analog. The oxychlorine-rich brine of Lake Vida constitutes a potential equivalent to perchlorate-rich preserved saline liquid water on Mars. We report here on the artifacts created by oxychlorines upon analysis of volatiles and volatile organic compounds (VOCs) of LVBr by direct immersion (DI) and head space (HS) solid phase micro extraction (SPME) gas chromatography-mass spectrometry (GCMS). We compare analytical blanks to a standard containing 40 μg/L of perchlorate and to actual LVBr sample runs. All blanks, perchlorate blanks and samples were analyzed using two types of SPME fibers, CarboxenTM/polydimethylsiloxane (PDMS) and divinylbenzene (DVB)/ PDMS. The similarities and differences between our results and those obtained by the Sample Analysis at Mars instruments of the rover Curiosity are discussed. The volatiles evolved from LVBr upon analysis with DI- and HS-SPME GCMS are dominated by CO2, dichloromethane, HCl, and volatile organic sulfur compounds (VOSCs, such as DMS, DMDS). The volatiles also include oxygenated compounds such as acids and ketones, aromatic compounds, hydrocarbons, chlorinated compounds (dominated by dichloromethane). Apart from the VOSCs, short chain hydrocarbons and some functionalized compounds derived from the brine itself, all compounds observed are artifacts formed upon oxychlorine breakdown in the injector of the GCMS. The distribution of aromatic compounds seems to be directly dependant on the type of SPME fiber used. The perchlorate blanks show a clear pattern of carbon limitation, likely affecting the type and abundance of compounds produced. This suggests that carbon limited perchlorates blanks are not satisfactory for comparison to the analysis of oxychlorine containing samples. Acknowledgment: NASA ASTEP NAG5-12889 (PTD), NSF awards ANT-0739681 (AEM, CHF) and ANT-0739698 (PTD, FK) supported this work.
Aminzahed, Iman; Mashhadi, Mahmoud Mosavi; Sereshk, Mohammad Reza Vaziri
2017-02-01
Micro forming is a manufacturing process to fabricate micro parts with high quality and a cost effective manner. Deep drawing could be a favorable method for production of complicated parts in macro and micro sizes. In this paper piezoelectric actuator is used as a novel approach in the field of micro manufacturing. Also, in current work, investigations are conducted with four rectangular punches and blanks with various thicknesses. Blank holder pressure effects on thickness distributions, punch force, and springback are studied. According to the results of this work, increasing of blank holder pressure in scaled deep drawing, in contrast to thickness of drawn part, leads to decrease in the punch forces and springback. Furthermore, it is shown that in micro deep drawing, the effects of holder pressure on mentioned parameters can be ignored. Copyright © 2016 Elsevier B.V. All rights reserved.
Kos, Gregor; Krska, Rudolf; Lohninger, Hans; Griffiths, Peter R
2004-01-01
An investigation into the rapid detection of mycotoxin-producing fungi on corn by two mid-infrared spectroscopic techniques was undertaken. Corn samples from a single genotype (RWA2, blanks, and contaminated with Fusarium graminearum) were ground, sieved and, after appropriate sample preparation, subjected to mid-infrared spectroscopy using two different accessories (diffuse reflection and attenuated total reflection). The measured spectra were evaluated with principal component analysis (PCA) and the blank and contaminated samples were classified by cluster analysis. Reference data for fungal metabolites were obtained with conventional methods. After extraction and clean-up, each sample was analyzed for the toxin deoxynivalenol (DON) by gas chromatography with electron capture detection (GC-ECD) and ergosterol (a parameter for the total fungal biomass) by high-performance liquid chromatography with diode array detection (HPLC-DAD). The concentration ranges for contaminated samples were 880-3600 microg/kg for ergosterol and 300-2600 microg/kg for DON. Classification efficiency was 100% for ATR spectra. DR spectra did not show as obvious a clustering of contaminated and blank samples. Results and trends were also observed in single spectra plots. Quantification using a PLS1 regression algorithm showed good correlation with DON reference data, but a rather high standard error of prediction (SEP) with 600 microg/kg (DR) and 490 microg/kg (ATR), respectively, for ergosterol. Comparing measurement procedures and results showed advantages for the ATR technique, mainly owing to its ease of use and the easier interpretation of results that were better with respect to classification and quantification.
NASA Astrophysics Data System (ADS)
Stanke, J.; Trauth, D.; Feuerhack, A.; Klocke, F.
2017-09-01
Die roll is a morphological feature of fine blanked sheared edges. The die roll reduces the functional part of the sheared edge. To compensate for the die roll thicker sheet metal strips and secondary machining must be used. However, in order to avoid this, the influence of various fine blanking process parameters on the die roll has been experimentally and numerically studied, but there is still a lack of knowledge on the effects of some factors and especially factor interactions on the die roll. Recent changes in the field of artificial intelligence motivate the hybrid use of the finite element method and artificial neural networks to account for these non-considered parameters. Therefore, a set of simulations using a validated finite element model of fine blanking is firstly used to train an artificial neural network. Then the artificial neural network is trained with thousands of experimental trials. Thus, the objective of this contribution is to develop an artificial neural network that reliably predicts the die roll. Therefore, in this contribution, the setup of a fully parameterized 2D FE model is presented that will be used for batch training of an artificial neural network. The FE model enables an automatic variation of the edge radii of blank punch and die plate, the counter and blank holder force, the sheet metal thickness and part diameter, V-ring height and position, cutting velocity as well as material parameters covered by the Hensel-Spittel model for 16MnCr5 (1.7131, AISI/SAE 5115). The FE model is validated using experimental trails. The results of this contribution is a FE model suitable to perform 9.623 simulations and to pass the simulated die roll width and height automatically to an artificial neural network.
Sun, Chong; Yang, Xiao-Di; Fan, Liu-Yin; Zhang, Wei; Xu, Yu-Quan; Cao, Cheng-Xi
2011-04-01
As shown herein, a normal moving reaction boundary (MRB) formed by an alkaline buffer and a single acidic buffer had poor stacking to the new important plant growth promoter of phenazine-1-carboxylic acid (PCA) in soil due to the leak induced by its low pK(a). To stack the PCA with low pK(a) efficiently, a novel stacking system of MRB was developed, which was formed by an alkaline buffer and double acidic buffers (viz., acidic sample and blank buffers). With the novel system, the PCA leaking into the blank buffer from the sample buffer could be well stacked by the prolonged MRB formed between the alkaline buffer and blank buffer. The relevant mechanism of stacking was discussed briefly. The stacking system, coupled with sample pretreatment, could achieve a 214-fold increase of PCA sensitivity under the optimal conditions (15 mM (pH 11.5) Gly-NaOH as the alkaline buffer, 15 mM (pH 3.0) Gly-HCl-acetonitrile (20%, v/v) as the acidic sample buffer, 15 mM (pH 3.0) Gly-HCl as the blank buffer, 3 min 13 mbar injection of double acidic buffers, benzoic acid as the internal standard, 75 μm i.d. × 53 cm (44 cm effective length) capillary, 25 kV and 248 nm). The limit of detection of PCA in soil was decreased to 17 ng/g, the intra-day and inter-day precision values (expressed as relative standard deviations) were 3.17-4.24% and 4.17-4.87%, respectively, and the recoveries of PCA at three concentration levels changed from 52.20% to 102.61%. The developed method could be used for the detection of PCA in soil at trace level.
Su, Wen-jin; Wang, Li-min; Weng, Shao-fan; Wang, Hai-jiao; Du, Li-li; Liu, Yue-wei; Yang, Lei; Chen, Wei-hong
2008-04-01
To assess the effects of the alteration of humidity and (or) temperature on weight of filters without and with ambient particulate matter in a balance room. The mass of blank dust sampling filters were weighed under (18 +/- 1) degrees C and (28 +/- 1) degrees C respectively, with the humidity varying from 35% relative humidity (RH) to 100% RH in a balance room. Then the blank filters were divided into two groups and were used to sample total dust and respirable dust. After sampling, the loaded filters were re-weighed under above conditions and the mass difference before and after the sampling were compared and analyzed. The vibration of the average mass of filters varied from 0.10 to 0.13 mg and from 0.06 to 0.09 mg under the temperatures of (18 +/- 1) degrees C and (28 +/- 1) degrees C respectively; When both the temperature and humidity changed, it varied from 0.12 to 0.16 mg. The deviation of average mass difference ranged from 0.07 to 0.10 mg and from 0.04 to 0.08 mg under the two temperatures mentioned above; When both the temperature and humidity changed, it varied from 0.09 to 0.14 mg. The average mass of blank filters and loaded filters were all positively correlated with the change of humidity (P < 0.01). No effects of humidity on the average mass difference of the loaded filters were observed. The average mass differences of loaded filters and blank filters under (18 +/- 1) degrees C were significantly higher than that under (28 +/- 1) degrees C (P < 0.01) when humidity was not changed. The alteration of humidity and (or) temperature in a balance room attributes to the deviation of the measurement of the mass of filters and thus affects the gravimetric measurements of ambient particulate matter.
Process Design of Aluminum Tailor Heat Treated Blanks.
Kahrimanidis, Alexander; Lechner, Michael; Degner, Julia; Wortberg, Daniel; Merklein, Marion
2015-12-09
In many industrials field, especially in the automotive sector, there is a trend toward lightweight constructions in order to reduce the weight and thereby the CO₂ and NO x emissions of the products. An auspicious approach within this context is the substitution of conventional deep drawing steel by precipitation hardenable aluminum alloys. However, based on the low formability, the application for complex stamping parts is challenging. Therefore, at the Institute of Manufacturing Technology, an innovative technology to enhance the forming limit of these lightweight materials was invented. The key idea of the so-called Tailor Heat Treated Blanks (THTB) is optimization of the mechanical properties by local heat treatment before the forming operation. An accurate description of material properties is crucial to predict the forming behavior of tailor heat treated blanks by simulation. Therefore, within in this research project, a holistic approach for the design of the THTB process in dependency of the main influencing parameters is presented and discussed in detail. The capability of the approach for the process development of complex forming operations is demonstrated by a comparison of local blank thickness of a tailgate with the corresponding results from simulation.
Process Design of Aluminum Tailor Heat Treated Blanks
Kahrimanidis, Alexander; Lechner, Michael; Degner, Julia; Wortberg, Daniel; Merklein, Marion
2015-01-01
In many industrials field, especially in the automotive sector, there is a trend toward lightweight constructions in order to reduce the weight and thereby the CO2 and NOx emissions of the products. An auspicious approach within this context is the substitution of conventional deep drawing steel by precipitation hardenable aluminum alloys. However, based on the low formability, the application for complex stamping parts is challenging. Therefore, at the Institute of Manufacturing Technology, an innovative technology to enhance the forming limit of these lightweight materials was invented. The key idea of the so-called Tailor Heat Treated Blanks (THTB) is optimization of the mechanical properties by local heat treatment before the forming operation. An accurate description of material properties is crucial to predict the forming behavior of tailor heat treated blanks by simulation. Therefore, within in this research project, a holistic approach for the design of the THTB process in dependency of the main influencing parameters is presented and discussed in detail. The capability of the approach for the process development of complex forming operations is demonstrated by a comparison of local blank thickness of a tailgate with the corresponding results from simulation. PMID:28793727
6 CFR 37.17 - Requirements for the surface of the driver's license or identification card.
Code of Federal Regulations, 2010 CFR
2010-01-01
... name field, and the first and middle name fields should be left blank. Place holders such as NFN, NMN...://www.ansi.org, or by contacting ANSI at ANSI, 25 West 43rd Street, 4th Floor, New York, New York 10036...
NASA Astrophysics Data System (ADS)
Klein, Matthias; Vaes, W. H. J.; Fabriek, B.; Sandman, H.; Mous, D. J. W.; Gottdang, A.
2013-01-01
The Netherlands Organization for Applied Scientific Research (TNO) has installed a compact 1 MV multi-element AMS system manufactured by High Voltage Engineering Europa B.V., The Netherlands. TNO performs clinical research programs for pharmaceutical and innovative foods industry to obtain early pharmacokinetic data and to provide anti-osteoporotic efficacy data of new treatments. The AMS system will analyze carbon, iodine and calcium samples for this purpose. The first measurements on blank samples indicate background levels in the low 10-12 for calcium and iodine, making the system well suited for these biomedical applications. Carbon blanks have been measured at low 10-16. For unattended, around-the-clock analysis, the system features the 200 sample version of the SO110 hybrid ion source and user friendly control software.
Damschen, William C.; Hansel, John A.; Nustad, Rochelle A.
2008-01-01
From January through October 2006, six sets of water-quality samples were collected at 28 sites, which included inflow and outflow from seven major municipal water-treatment plants (14 sites) and influent and effluent samples from seven major municipal wastewater treatment plants (14 sites) along the Red River of the North in North Dakota and Minnesota. Samples were collected in cooperation with the Bureau of Reclamation for use in the development of return-flow boundary conditions in a 2006 water-quality model for the Red River of the North. All samples were analyzed for nutrients and major ions. For one set of effluent samples from each of the wastewater-treatment plants, water was analyzed for Eschirichia coli, fecal coliform, 20-day biochemical oxygen demand, 20-day nitrogenous biochemical oxygen demand, total organic carbon, and dissolved organic carbon. In general, results from the field equipment blank and replicate samples indicate that the overall process of sample collection, processing, and analysis did not introduce substantial contamination and that consistent results were obtained.
VLA and ALMA Imaging of Intense Galaxy-wide Star Formation in z ˜ 2 Galaxies
NASA Astrophysics Data System (ADS)
Rujopakarn, W.; Dunlop, J. S.; Rieke, G. H.; Ivison, R. J.; Cibinel, A.; Nyland, K.; Jagannathan, P.; Silverman, J. D.; Alexander, D. M.; Biggs, A. D.; Bhatnagar, S.; Ballantyne, D. R.; Dickinson, M.; Elbaz, D.; Geach, J. E.; Hayward, C. C.; Kirkpatrick, A.; McLure, R. J.; Michałowski, M. J.; Miller, N. A.; Narayanan, D.; Owen, F. N.; Pannella, M.; Papovich, C.; Pope, A.; Rau, U.; Robertson, B. E.; Scott, D.; Swinbank, A. M.; van der Werf, P.; van Kampen, E.; Weiner, B. J.; Windhorst, R. A.
2016-12-01
We present ≃0.″4 resolution extinction-independent distributions of star formation and dust in 11 star-forming galaxies (SFGs) at z = 1.3-3.0. These galaxies are selected from sensitive blank-field surveys of the 2‧ × 2‧ Hubble Ultra-Deep Field at λ = 5 cm and 1.3 mm using the Karl G. Jansky Very Large Array and Atacama Large Millimeter/submillimeter Array. They have star formation rates (SFRs), stellar masses, and dust properties representative of massive main-sequence SFGs at z ˜ 2. Morphological classification performed on spatially resolved stellar mass maps indicates a mixture of disk and morphologically disturbed systems; half of the sample harbor X-ray active galactic nuclei (AGNs), thereby representing a diversity of z ˜ 2 SFGs undergoing vigorous mass assembly. We find that their intense star formation most frequently occurs at the location of stellar-mass concentration and extends over an area comparable to their stellar-mass distribution, with a median diameter of 4.2 ± 1.8 kpc. This provides direct evidence of galaxy-wide star formation in distant blank-field-selected main-sequence SFGs. The typical galactic-average SFR surface density is 2.5 M ⊙ yr-1 kpc-2, sufficiently high to drive outflows. In X-ray-selected AGN where radio emission is enhanced over the level associated with star formation, the radio excess pinpoints the AGNs, which are found to be cospatial with star formation. The median extinction-independent size of main-sequence SFGs is two times larger than those of bright submillimeter galaxies, whose SFRs are 3-8 times larger, providing a constraint on the characteristic SFR (˜300 M ⊙ yr-1) above which a significant population of more compact SFGs appears to emerge.
Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.
2001-01-01
A laboratory for analysis of low-ionic strength water has been developed at the U.S. Geological Survey (USGS) office in Troy, N.Y., to analyze samples collected by USGS projects in the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures developed to ensure proper sample collection, processing, and analysis. The quality-assurance/quality-control data are stored in the laboratory's SAS data-management system, which provides efficient review, compilation, and plotting of quality-assurance/quality-control data. This report presents and discusses samples analyzed from July 1993 through June 1995. Quality-control results for 18 analytical procedures were evaluated for bias and precision. Control charts show that data from seven of the analytical procedures were biased throughout the analysis period for either high-concentration or low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, dissolved inorganic carbon, dissolved organic carbon (soil expulsions), chloride, magnesium, nitrate (colorimetric method), and pH. Three of the analytical procedures were occasionally biased but were within control limits; they were: calcium (high for high-concentration samples for May 1995), dissolved organic carbon (high for highconcentration samples from January through September 1994), and fluoride (high in samples for April and June 1994). No quality-control sample has been developed for the organic monomeric aluminum procedure. Results from the filter-blank and analytical-blank analyses indicate that all analytical procedures in which blanks were run were within control limits, although values for a few blanks were outside the control limits. Blanks were not analyzed for acid-neutralizing capacity, dissolved inorganic carbon, fluoride, nitrate (colorimetric method), or pH. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in 14 of the 18 procedures. Data-quality objectives were met by more than 90 percent of the samples analyzed in all procedures except total monomeric aluminum (85 percent of samples met objectives), total aluminum (70 percent of samples met objectives), and dissolved organic carbon (85 percent of samples met objectives). Triplicate samples were not analyzed for ammonium, fluoride, dissolved inorganic carbon, or nitrate (colorimetric method). Results of the USGS interlaboratory Standard Reference Sample Program indicated high data quality with a median result of 3.6 of a possible 4.0. Environment Canada's LRTAP interlaboratory study results indicated that more than 85 percent of the samples met data-quality objectives in 6 of the 12 analyses; exceptions were calcium, dissolved organic carbon, chloride, pH, potassium, and sodium. Data-quality objectives were not met for calcium samples in one LRTAP study, but 94 percent of samples analyzed were within control limits for the remaining studies. Data-quality objectives were not met by 35 percent of samples analyzed for dissolved organic carbon, but 94 percent of sample values were within 20 percent of the most probable value. Data-quality objectives were not met for 30 percent of samples analyzed for chloride, but 90 percent of sample values were within 20 percent of the most probable value. Measurements of samples with a pH above 6.0 were biased high in 54 percent of the samples, although 85 percent of the samples met data-quality objectives for pH measurements below 6.0. Data-quality objectives for potassium and sodium were not met in one study (only 33 percent of the samples analyzed met the objectives), although 85 percent of the sample values were within control limits for the other studies. Measured sodium values were above the upper control limit in all studies. Results from blind reference-sample analyses indicated that data
NASA Astrophysics Data System (ADS)
Sander, R.; Pszenny, A. A. P.; Keene, W. C.; Crete, E.; Deegan, B.; Long, M. S.; Maben, J. R.; Young, A. H.
2013-07-01
We report mixing ratios of soluble reactive trace gases sampled with mist chambers and the chemical composition of bulk aerosol and volatile inorganic bromine (Brg) sampled with filter packs during the Reactive Halogens in the Marine Boundary Layer (RHaMBLe) field campaign at the Cape Verde Atmospheric Observatory (CVAO) on São Vicente island in the tropical North Atlantic in May and June 2007. The gas-phase data include HCl, HNO3, HONO, HCOOH, CH3COOH, NH3, and volatile reactive chlorine other than HCl (Cl*). Aerosol samples were analyzed by neutron activation (Na, Al, Cl, V, Mn, and Br) and ion chromatography (SO42-, Cl-, Br-, NH4+, Na+, K+, Mg2+, and Ca2+). Content and quality of the data, which are available under doi:10.5281/zenodo.6956, are presented and discussed.
NASA Astrophysics Data System (ADS)
Sander, R.; Pszenny, A. A. P.; Keene, W. C.; Crete, E.; Deegan, B.; Long, M. S.; Maben, J. R.; Young, A. H.
2013-12-01
We report mixing ratios of soluble reactive trace gases sampled with mist chambers and the chemical composition of bulk aerosol and volatile inorganic bromine (Brg) sampled with filter packs during the Reactive Halogens in the Marine Boundary Layer (RHaMBLe) field campaign at the Cape Verde Atmospheric Observatory (CVAO) on São Vicente island in the tropical North Atlantic in May and June 2007. The gas-phase data include HCl, HNO3, HONO, HCOOH, CH3COOH, NH3, and volatile reactive chlorine other than HCl (Cl*). Aerosol samples were analyzed by neutron activation (Na, Al, Cl, V, Mn, and Br) and ion chromatography (SO42-, Cl-, Br-, NH4+, Na+, K+, Mg2+, and Ca2+). Content and quality of the data, which are available under doi:10.5281/zenodo.6956, are presented and discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bostick, Debra A.; Hexel, Cole R.; Ticknor, Brian W.
2016-11-01
To shorten the lengthy and costly manual chemical purification procedures, sample preparation methods for mass spectrometry are being automated using commercial-off-the-shelf (COTS) equipment. This addresses a serious need in the nuclear safeguards community to debottleneck the separation of U and Pu in environmental samples—currently performed by overburdened chemists—with a method that allows unattended, overnight operation. In collaboration with Elemental Scientific Inc., the prepFAST-MC2 was designed based on current COTS equipment that was modified for U/Pu separations utilizing Eichrom™ TEVA and UTEVA resins. Initial verification of individual columns yielded small elution volumes with consistent elution profiles and good recovery. Combined columnmore » calibration demonstrated ample separation without crosscontamination of the eluent. Automated packing and unpacking of the built-in columns initially showed >15% deviation in resin loading by weight, which can lead to inconsistent separations. Optimization of the packing and unpacking methods led to a reduction in the variability of the packed resin to less than 5% daily. The reproducibility of the automated system was tested with samples containing 30 ng U and 15 pg Pu, which were separated in a series with alternating reagent blanks. These experiments showed very good washout of both the resin and the sample from the columns as evidenced by low blank values. Analysis of the major and minor isotope ratios for U and Pu provided values well within data quality limits for the International Atomic Energy Agency. Additionally, system process blanks spiked with 233U and 244Pu tracers were separated using the automated system after it was moved outside of a clean room and yielded levels equivalent to clean room blanks, confirming that the system can produce high quality results without the need for expensive clean room infrastructure. Comparison of the amount of personnel time necessary for successful manual vs. automated chemical separations showed a significant decrease in hands-on time from 9.8 hours to 35 minutes for seven samples, respectively. This documented time savings and reduced labor translates to a significant cost savings per sample. Overall, the system will enable faster sample reporting times at reduced costs by limiting personnel hours dedicated to the chemical separation.« less
2008-09-01
day timeframe. 3.6 DEMONSTRATOR’S FIELD PERSONNEL Geophysicist: Craig Hyslop Geophysicist: John Jacobsen Geophysicist: Rob Mehl 3.7...Practical Nonparametric Statistics, W.J. Conover, John Wiley & Sons, 1980 , pages 144 through 151. F-1 (Page F-2 Blank) APPENDIX F
Preliminary measurements of 135Cs with AMS
NASA Astrophysics Data System (ADS)
Yin, Xinyi; He, Ming; Dong, Kejun; Dou, Liang; Lan, Xiaoxi; Pang, Fangfang; Wu, Shaoyong; Jiang, Shan
2015-10-01
135Cs is an interesting nuclide in many research fields, especially in environmental study. Preliminary measurements of the long-lived 135Cs with accelerator mass spectrometry (AMS) have been developed with the HI-13 tandem AMS facility at China Institute of Atomic Energy (CIAE). In order to improve ion extracting current and depressing background interference, experiments were carried out on different ions of Cs extracted from different samples. It was found that Cs- extracted from CsNO3 can be used for AMS measurement of 135Cs. According to the preliminary results, the background level can be obtained with blanks was 135Ba/Cs ∼ 8.8 × 10-12 with the CIAE-AMS system.
Guimaraes, Wladmir B.; Falls, W. Fred; Caldwell, Andral W.; Ratliff, W. Hagan; Wellborn, John B.; Landmeyer, James E.
2011-01-01
The U.S. Geological Survey, in cooperation with the U.S. Department of the Army Environmental and Natural Resources Management Office of the U.S. Army Signal Center and Fort Gordon, Georgia, assessed the hyporheic zone, flood plain, soil gas, soil, and surface water for contaminants at the McCoys Creek Chemical Training Area (MCTA) at Fort Gordon, from October 2009 to September 2010. The assessment included the detection of organic contaminants in the hyporheic zone, flood plain, soil gas, and surface water. In addition, the organic contaminant assessment included the analysis of organic compounds classified as explosives and chemical agents in selected areas. Inorganic contaminants were assessed in soil and surface-water samples. The assessment was conducted to provide environmental contamination data to the U.S. Army at Fort Gordon pursuant to requirements of the Resource Conservation and Recovery Act Part B Hazardous Waste Permit process. Ten passive samplers were deployed in the hyporheic zone and flood plain, and total petroleum hydrocarbons (TPH) and octane were detected above the method detection level in every sampler. Other organic compounds detected above the method detection level in the hyporheic zone and flood-plain samplers were trichloroethylene, and cis- and trans- 1, 2-dichloroethylene. One trip blank detected TPH below the method detection level but above the nondetection level. The concentrations of TPH in the samplers were many times greater than the concentrations detected in the blank; therefore, all other TPH concentrations detected are considered to represent environmental conditions. Seventy-one soil-gas samplers were deployed in a grid pattern across the MCTA. Three trip blanks and three method blanks were used and not deployed, and TPH was detected above the method detection level in two trip blanks and one method blank. Detection of TPH was observed at all 71 samplers, but because TPH was detected in the trip and method blanks, TPH was censored and, therefore, only 7 of the 71 samplers were reported as detecting TPH. In addition, benzene, toluene, ethylbenzene, and total xylene were detected above the method detection level in 22 samplers. Other compounds detected above the method detection level included naphthalene, octane, undecane, tridecane, 1,2,4-trimethylbenzene, trichloroethylene, perchloroethylene, chloroform, and 1,4-dichlorobenzene. Subsequent to the soil-gas survey, five locations with elevated contaminant mass were selected and a passive sampler was deployed at those locations to detect the presence of organic compounds classified as explosives or chemical agents. No explosives or chemical agents were detected above the method detection level, but some compounds were detected below the method detection level but above the nondetection level. Dimethyl disulfide, benzothiazole, chloroacetophenones, and para-chlorophenyl methyl sulfide were all detected below the method detection level but above the nondetection level. The compounds 2,4-dinitrotoluene, and para-chlorophenyl methyl sulfone were detected in samplers but also were detected in trip blanks and are not considered as present in the MCTA. The same five locations that were selected for sampling of explosives and chemical agents were selected for soil sampling. Metal concentrations in composite soil samples collected at five locations from land surface to a depth of 6 inches did not exceed the U.S. Environmental Protection Agency Regional Screening Levels for Industrial Soil. Concentrations in some compounds were higher than the South Carolina Department of Health and Environmental Control background levels for nearby South Carolina, including aluminum, arsenic, barium, beryllium, chromium, copper, iron, lead, manganese, nickel, and potassium. A surface-water sample was collected from McCoys Creek and analyzed for volatile organic compounds, semivolatile organic compounds, and inorganic compounds (metals). No volatile organic compounds and (or) semivolatile organic compounds were detected at levels above the maximum contaminant level of the U.S. Environmental Protection Agency (USEPA) National Primary Drinking Water Standard, and no inorganic compounds exceeded the maximum contaminant level of the USEPA National Primary Drinking Water Standard or the Georgia In-Stream Water-Quality Standard. Iron was the only inorganic compound detected in the surface-water sample (578 micrograms per liter) that exceeded the USEPA National Secondary Drinking Water Standard of 300 micrograms per liter.
Properties of an H I-selected galaxy sample
NASA Technical Reports Server (NTRS)
Szomoru, Arpad; Guhathakurta, Puragra; Van Gorkom, Jacqueline H.; Knapen, Johan H.; Weinberg, David H.; Fruchter, Andrew S.
1994-01-01
We analyze the properties of a sample of galaxies identified in a 21cm, H I-line survey of selected areas in the Perseus-Pisces supercluster and its foreground void. Twelve fields were observed in the supercluster, five of them (target fields) centered on optically bright galaxies, and the other seven (blank fields) selected to contain no bright galaxies within 45 min. of their centers. We detected nine previously uncatalogued, gas-rich galaxies, six of them in the target fields. We also detected H I from seven previously catalogued galaxies in these fields. Observations in the void covered the same volume as the 12 supercluster fields at the same H I-mass sensitivity, but no objects were detected. Combining out H I data with optical broadband and H alpha imaging, we conclude that the properties of H I-selected galaxies do not differ substantially from those of late-type galaxies found in optical surveys. In particular, the galaxies in our sample do not appear to be unusually faint for their H I mass, or for their circular velocity. We find tentative evidence for a connection between optical surface brightness and degree of isolation, in the sense that low surface brightness galaxies tend to be more isolated. The previously catalogued, optically bright galaxies in our survey volume dominate the total H I mass density and cross section; the uncatalogued galaxies contribute only approximately 19 percent of the mass and approximately 12 percent of the cross section. Thus, existing estimates of the density and cross section of neutral hydrogen, most of which are based on optically selected galaxy samples, are probably accurate. Such estimates can be used to compare the nearby universe to the high-redshift universe probed by quasar absorption lines.
Lessons learned in preparing method 29 filters for compliance testing audits.
Martz, R F; McCartney, J E; Bursey, J T; Riley, C E
2000-01-01
Companies conducting compliance testing are required to analyze audit samples at the time they collect and analyze the stack samples if audit samples are available. Eastern Research Group (ERG) provides technical support to the EPA's Emission Measurements Center's Stationary Source Audit Program (SSAP) for developing, preparing, and distributing performance evaluation samples and audit materials. These audit samples are requested via the regulatory Agency and include spiked audit materials for EPA Method 29-Metals Emissions from Stationary Sources, as well as other methods. To provide appropriate audit materials to federal, state, tribal, and local governments, as well as agencies performing environmental activities and conducting emission compliance tests, ERG has recently performed testing of blank filter materials and preparation of spiked filters for EPA Method 29. For sampling stationary sources using an EPA Method 29 sampling train, the use of filters without organic binders containing less than 1.3 microg/in.2 of each of the metals to be measured is required. Risk Assessment testing imposes even stricter requirements for clean filter background levels. Three vendor sources of quartz fiber filters were evaluated for background contamination to ensure that audit samples would be prepared using filters with the lowest metal background levels. A procedure was developed to test new filters, and a cleaning procedure was evaluated to see if a greater level of cleanliness could be achieved using an acid rinse with new filters. Background levels for filters supplied by different vendors and within lots of filters from the same vendor showed a wide variation, confirmed through contact with several analytical laboratories that frequently perform EPA Method 29 analyses. It has been necessary to repeat more than one compliance test because of suspect metals background contamination levels. An acid cleaning step produced improvement in contamination level, but the difference was not significant for most of the Method 29 target metals. As a result of our studies, we conclude: Filters for Method 29 testing should be purchased in lots as large as possible. Testing firms should pre-screen new boxes and/or new lots of filters used for Method 29 testing. Random analysis of three filters (top, middle, bottom of the box) from a new box of vendor filters before allowing them to be used in field tests is a prudent approach. A box of filters from a given vendor should be screened, and filters from this screened box should be used both for testing and as field blanks in each test scenario to provide the level of quality assurance required for stationary source testing.
Li, Minghua; Peng, Li; Yang, Fuheng; Liu, Sijia; Wang, Shengqi
2015-06-01
To evaluate the effect of Radix euphorbiae pekinensis extract on the permeability and bioavailability of paclitaxel co-administered orally. Based on Ussing Chamber and in vivo experiment, the permeability and bioavailability of paclitaxel were evaluated after oral co-administration with radix euphorbiae pekinensis in rats. The contents of paclitaxel in the permeates and the blood samples were determined using HPLC and LC-MS/MS method, respectively. In Radix euphorbiae pekinensis co-administration group, the Papp of the mucosal-to-serosal (M-S) transport or serosal-to-mucosal transport (S-M) of paclitaxel in the jejunum or ileum segment differed significantly from those in verapamil co-administration group and blank control group (P<0.05), but the Papp of S-M transport in the colon showed no significant difference from that in the blank control group. In the blank group, the average absolute bioavailability (AB%) of orally administered paclitaxel was only 2.81%, compared to that of 7.63% in radix euphorbiae pekinensis group. The average AB% in verapamil group was about 1.5 times that of the blank group. Co-administration of Radix euphorbiae pekinensis extract can increase the bioavailability of orally administered paclitaxel.
NASA Astrophysics Data System (ADS)
Johnson, L.; Komada, T.
2010-12-01
The abundances of natural 14C in dissolved organic carbon (DOC) in the marine environment hold clues regarding the processes that influence the biogeochemical cycling of this large carbon reservoir. At present, UV irradiation is the widely accepted method for oxidizing seawater DOC for determination of their 14C abundances. This technique yields precise and accurate values with low blanks, but it requires a dedicated vacuum line, and hence can be difficult to implement. As an alternative technique that can be conducted on a standard preparatory vacuum line, we modified and tested a thermal sulfate reduction method that was previously developed to determine δ13C values of marine DOC (Fry B. et al., 1996. Analysis of marine DOC using a dry combustion method. Mar. Chem., 54: 191-201.) to determine the 14C abundances of DOC in marine sediment porewaters. In this method, the sample is dried in a 100 ml round-bottom Pyrex flask in the presence of excess oxidant (K2SO4) and acid (H3PO4), and combusted at 550 deg.C. The combustion products are cryogenically processed to collect and quantify CO2 using standard procedures. Materials we have oxidized to date range from 6-24 ml in volume, and 95-1500 μgC in size. The oxidation efficiency of this method was tested by processing known amounts of reagent-grade dextrose and sucrose (as examples of labile organic matter), tannic acid and humic acid (as examples of complex natural organic matter), and porewater DOC extracted from organic-rich nearshore sediments. The carbon yields for all of these materials averaged 99±4% (n=18). The 14C abundances of standard materials IAEA C-6 and IAEA C-5 processed by this method using >1mgC aliquots were within error of certified values. The size and the isotopic value of the blank were determined by a standard dilution technique using IAEA C-6 and IAEA C-5 that ranged in size from 150 to 1500 μgC (n=4 and 2, respectively). This yielded a blank size of 6.7±0.7 μgC, and a blank isotopic value of 0.54±0.05 fMC. The size of the blank agreed well with that determined directly by processing variable volumes of UV-irradiated deionized water (5.6±0.7 μgC, n=9). The size of the blank amounts to <~5% of the size of porewater DOC samples that are typically recovered from organic-rich sediment cores (~100-500 μgC). The fMC value of the blank suggests that there may be multiple sources of extraneous carbon that range in 14C abundance. In order to assess the fidelity of 14C abundances in natural porewater DOC oxidized by thermal sulfate reduction, we oxidized porewater DOC samples collected from the central floor of the Santa Monica Basin, California Borderland, using both this method and UV irradiation (the latter carried out at the Druffel laboratory, University of California Irvine). The fMC values obtained by the two methods agreed within error. Carbon yields from the two methods also agreed closely. These findings show that thermal sulfate reduction may be a promising method to oxidize small, concentrated marine DOC samples for 14C analysis.
NASA Astrophysics Data System (ADS)
Zavala, J. A.; Aretxaga, I.; Geach, J. E.; Hughes, D. H.; Birkinshaw, M.; Chapin, E.; Chapman, S.; Chen, Chian-Chou; Clements, D. L.; Dunlop, J. S.; Farrah, D.; Ivison, R. J.; Jenness, T.; Michałowski, M. J.; Robson, E. I.; Scott, Douglas; Simpson, J.; Spaans, M.; van der Werf, P.
2017-01-01
We present deep observations at 450 and 850 μm in the Extended Groth Strip field taken with the SCUBA-2 camera mounted on the James Clerk Maxwell Telescope as part of the deep SCUBA-2 Cosmology Legacy Survey (S2CLS), achieving a central instrumental depth of σ450 = 1.2 mJy beam-1 and σ850 = 0.2 mJy beam-1. We detect 57 sources at 450 μm and 90 at 850 μm with signal-to-noise ratio >3.5 over ˜70 arcmin2. From these detections, we derive the number counts at flux densities S450 > 4.0 mJy and S850 > 0.9 mJy, which represent the deepest number counts at these wavelengths derived using directly extracted sources from only blank-field observations with a single-dish telescope. Our measurements smoothly connect the gap between previous shallower blank-field single-dish observations and deep interferometric ALMA results. We estimate the contribution of our SCUBA-2 detected galaxies to the cosmic infrared background (CIB), as well as the contribution of 24 μm-selected galaxies through a stacking technique, which add a total of 0.26 ± 0.03 and 0.07 ± 0.01 MJy sr-1, at 450 and 850 μm, respectively. These surface brightnesses correspond to 60 ± 20 and 50 ± 20 per cent of the total CIB measurements, where the errors are dominated by those of the total CIB. Using the photometric redshifts of the 24 μm-selected sample and the redshift distributions of the submillimetre galaxies, we find that the redshift distribution of the recovered CIB is different at each wavelength, with a peak at z ˜ 1 for 450 μm and at z ˜ 2 for 850 μm, consistent with previous observations and theoretical models.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Atek, Hakim; Kneib, Jean-Paul; Richard, Johan
2015-02-10
Exploiting the power of gravitational lensing, the Hubble Frontier Fields (HFF) program aims at observing six massive galaxy clusters to explore the distant universe far beyond the limits of blank field surveys. Using the complete Hubble Space Telescope observations of the first HFF cluster A2744, we report the detection of 50 galaxy candidates at z ∼ 7 and eight candidates at z ∼ 8 in a total survey area of 0.96 arcmin{sup 2} in the source plane. Three of these galaxies are multiply imaged by the lensing cluster. Using an updated model of the mass distribution in the cluster we weremore » able to calculate the magnification factor and the effective survey volume for each galaxy in order to compute the ultraviolet galaxy luminosity function (LF) at both redshifts 7 and 8. Our new measurements reliably extend the z ∼ 7 UV LF down to an absolute magnitude of M {sub UV} ∼ –15.5. We find a characteristic magnitude of M{sub UV}{sup ⋆}=−20.90{sub −0.73}{sup +0.90} mag and a faint-end slope α=−2.01{sub −0.28}{sup +0.20}, close to previous determinations in blank fields. We show here for the first time that this slope remains steep down to very faint luminosities of 0.01 L {sup *}. Although prone to large uncertainties, our results at z ∼ 8 also seem to confirm a steep faint-end slope below 0.1 L {sup *}. The HFF program is therefore providing an extremely efficient way to study the faintest galaxy populations at z > 7 that would otherwise be inaccessible with current instrumentation. The full sample of six galaxy clusters will provide even better constraints on the buildup of galaxies at early epochs and their contribution to cosmic reionization.« less
NASA Astrophysics Data System (ADS)
Li, Yanhua; Lin, Jianping
2015-08-01
Tailor-welded blanks (TWBs) have been considered as a productive sheet forming method in automotive industries. However, formability of TWBs is reduced due to different properties or thicknesses of the blanks and is a challenge for manufacturing designers. The plastic capacity of TWBs is decreased even when the material and thickness are the same. The constraint effect of the laser weld (including weld and heat-affected zone) material in the forming process of similar TWBs is a key problem to be solved in the research, development and application of thin-sheet TWBs. In this paper, uniaxial tensile tests with full-field strain measurement by digital image correlation and Erichsen tests are performed to investigate the constraint effect on deformation behavior and explore the mechanism of decreasing formability of similar TWBs. In addition, finite element models are conducted under ABAQUS code to further reveal the phenomenal behavior of the constraint effect. The results of the base material and welded blanks are compared for characterizing the differences. Furthermore, in order to better understand this mechanism, theoretical and numerical investigations are employed and compared to interpret the constraint effect of laser weld on the deformation behavior of TWBs. An index is proposed to quantify the constraint effect. Results show that the constraint effect of laser weld appears in both stretch forming and drawing of TWBs. Strain paths are approaching the plane strain condition as compared to the monolithic blank due to the constraint effect. Constraint effect is a major factor affecting the formability of TWBs when the failure occurs away from the weld seam.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kieber, R.; Mopper, K.
1990-10-01
Low molecular weight carbonyl compounds in natural waters were determined at picomolar to nanomolar levels by derivatization with 2,4-dinitrophenylhydrazine followed by liquid chromatography. The uniqueness of the method is attributed to the extremely low blanks obtained and the minimal sample preparation involved. The detection limit for direct injection of derivatized natural water samples is 0.5 nM for aldehydes and 5 nM for ketones with a precision of {approximately}7% RSD at the 30 nM level for aldehydes. The detection limit can be further lowered by using off-line cartridge enrichment in which derivatized natural water is passed through a C18 extraction cartridge.more » Recoveries for the enrichment method were 95-105% for a sample volume of 20 mL and for concentrations of carbonyl compounds in the 1-30 nM range. A field procedure for storage of derivatized sample extracts for extended periods is also presented. Applications of enrichment and sample storage techniques to marine and estuarine waters are presented.« less
Status report: Implementation of gas measurements at the MAMS 14C AMS facility in Mannheim, Germany
NASA Astrophysics Data System (ADS)
Hoffmann, Helene; Friedrich, Ronny; Kromer, Bernd; Fahrni, Simon
2017-11-01
By implementing a Gas Interface System (GIS), CO2 gas measurements for radiocarbon dating of small environmental samples (<100 μgC) have been established at the MICADAS (Mini Carbon Dating System) AMS instrument in Mannheim, Germany. The system performance has been optimized and tested with respect to stability and ion yield by repeated blank and standard measurements for sample sizes down to 3 μgC. The highest 12C- low-energy (LE) ion currents, typically reaching 8-15 μA, could be achieved for a mixing ratio of 4% CO2 in Helium, resulting in relative counting errors of 1-2% for samples larger than 10 μgC and 3-7% for sample sizes below 10 μgC. The average count rate was ca. 500 counts per microgram C for OxII standard material. The blank is on the order of 35,000-40,000 radiocarbon years, which is comparable to similar systems. The complete setup thus enables reliable dating for most environmental samples (>3 μgC).
Method and apparatus for inspecting an EUV mask blank
Goldberg, Kenneth A.
2005-11-08
An apparatus and method for at-wavelength EUV mask-blank characterization for inspection of moderate and low spatial frequency coating uniformity using a synchrotron or other source of EUV light. The apparatus provides for rapid, non-destruction, non-contact, at-wavelength qualification of large mask areas, and can be self-calibrating or be calibrated to well-characterized reference samples. It can further check for spatial variation of mask reflectivity or for global differences among masks. The apparatus and method is particularly suited for inspection of coating uniformity and quality and can detect defects in the order of 50 .mu.m and above.
Tailor-welded blanks and their production
NASA Astrophysics Data System (ADS)
Yan, Qi
2005-01-01
Tailor welded blanks had been widely used in the automobile industry. A tailor welded blank consists of several flat sheets that were laser welded together before stamping. A combination of different materials, thickness, and coatings could be welded together to form a blank for stamping car body panels. As for the material for automobile industry, this technology was one of the development trend for automobile industry because of its weight reduction, safety improvement and economical use of materials. In this paper, the characters and production of tailor welded blanks in the market were discussed in detail. There had two major methods to produce tailor welded blanks. Laser welding would replace mesh seam welding for the production of tailor welded blanks in the future. The requirements on the edge preparation of unwelded blanks for tailor welded blanks were higher than the other steel processing technology. In order to produce the laser welded blank, there had the other process before the laser welding in the factory. In the world, there had three kinds of patterns for the large volume production of tailor welded blanks. In China, steel factory played the important role in the promotion of the application of tailor welded blanks. The competition for the supply of tailor welded blanks to the automobile industry would become fierce in the near future. As a result, the demand for the quality control on the production of tailor welded blanks would be the first priority concern for the factory.
Plausible Boosting of Millimeter-Galaxies in the COSMOS Field by Intervening Large-Scale Structure
NASA Astrophysics Data System (ADS)
Aretxaga, I.; Wilson, G. W.; Aguilar, E.; Alberts, S.; Scott, K. S.; Scoville, N.; Yun, M. S.; Austermann, J.; Downes, T. D.; Ezawa, H.; Hatsukade, B.; Hughes, D. H.; Kawabe, R.; Kohno, K.; Oshima, T.; Perera, T. A.; Tamura, Y.; Zeballos, M.
2011-10-01
The 0.72 sq. deg. contiguous 1.1mm survey in the central area of the COSMOS field, carried out to a 1σ≍1.26 mJy beam-1 depth with the AzTEC camera mounted on the 10m Atacama Submillimeter Telescope Experiment (ASTE), shows number counts with a significant excess of sources when compared to the number counts derived from the ˜0.5 sq. deg. area sampled at similar depths in the Scuba HAlf Degree Extragalactic Survey (SHADES, Austermann et al. 2010). They are, however, consistent with those derived from fields that were considered too small to characterize the overall blank-field population. We identify differences to be more significant in the S1.1mm ˜> 5 mJy regime, and demonstrate that these excesses in number counts are related to the areas where galaxies at redshifts ˜< 1.1 are more densely clustered. The positions of optical-IR galaxies in the redshift interval 0.6 ˜< z ˜< 0.75 are the ones that show the strongest correlation with the positions of the 1.1mm bright population (S1.mm ˜>5 mJy), a result which does not depend exclusively on the presence of rich clusters within the survey sampled area. The most likely explanation for the observed excess in number counts at 1.1mm is galaxy-galaxy and galaxy-group lensing at moderate amplification levels, that increases in amplitude as one samples larger and larger flux densities.
21 CFR 177.1950 - Vinyl chloride-ethylene copolymers.
Code of Federal Regulations, 2013 CFR
2013-04-01
... deciliter per gram as determined by ASTM method D1243-79, “Standard Test Method for Dilute Solution... vinyl chloride-ethylene copol-ymer per 100 grams of sample tested as determined from the organic... using duplicate blanks. Approximately 400 grams of sample (accurately weighed) shall be placed in a 2...
21 CFR 177.1950 - Vinyl chloride-ethylene copolymers.
Code of Federal Regulations, 2012 CFR
2012-04-01
... deciliter per gram as determined by ASTM method D1243-79, “Standard Test Method for Dilute Solution... vinyl chloride-ethylene copol-ymer per 100 grams of sample tested as determined from the organic... using duplicate blanks. Approximately 400 grams of sample (accurately weighed) shall be placed in a 2...
Imaging Gallium Nitride High Electron Mobility Transistors to Identify Point Defects
2014-03-01
streamline the sample preparation procedure to maximize the yield of successful samples to be analyzed chemically in an energy dispersive spectrometry...transmission electron microscope (STEM), sample preparation 15. NUMBER OF PAGES 103 16. PRICE CODE 17. SECURITY CLASSIFICATION OF REPORT...Computer Engineering iii THIS PAGE INTENTIONALLY LEFT BLANK iv ABSTRACT The purpose of this thesis is to streamline the sample preparation
Galaxy evolution at high-redshift: Millimeter-wavelength surveys with the AzTEC camera
NASA Astrophysics Data System (ADS)
Scott, Kimberly S.
Galaxies detected by their thermal dust emission at submillimeter (submm) and millimeter (mm) wavelengths comprise a population of massive, intensely star-forming systems in the early Universe. These "submm/mm- galaxies", or SMGs, likely represent an important phase in the assembly and/or evolution of massive galaxies and are thought to be the progenitors of massive elliptical galaxies. While their projected number density as a function of source brightness provides key constraints on models of galaxy evolution, SMG surveys carried out over the past twelve years with the first generation of submm/mm-wavelength cameras have not imaged a large enough area to sufficient depths to provide the statistical power needed to discriminate between competing galaxy evolution scenarios. In this dissertation, we present the results from SMG surveys carried out over the past four years using the new sensitive mm-wavelength camera AzTEC. With the improved mapping speed of the AzTEC camera combined with dedicated telescope time devoted to deep, large-area extragalactic surveys, we have tripled both the area surveyed towards blank- fields (that is, regions with no known galaxy over-densities) at submm/mm wavelengths and the total number of detected SMGs. Here, we describe the properties and performance of the AzTEC instrument while operating on the James Clerk Maxwell Telescope (JCMT) and the Atacama Submillimeter Telescope Experiment (ASTE). We then present the results from two of the blank-field regions imaged with AzTEC: the JCMT/COSMOS field, which we discovered is over- dense in the number of very bright SMGs, and the ASTE survey of the Great Observatories Origins Deep-South field, which represents one of the deepest surveys ever carried out at submm/mm wavelengths. Finally, we combine the results from all of the blank-fields imaged with AzTEC while operating on the JCMT and the ASTE to calculate the most accurate measurements to date of the SMG number counts.
NASA Astrophysics Data System (ADS)
Willmes, M.; McMorrow, L.; Kinsley, L.; Armstrong, R.; Aubert, M.; Eggins, S.; Falguères, C.; Maureille, B.; Moffat, I.; Grün, R.
2013-11-01
Strontium isotope ratios (87Sr/86Sr) are a key geochemical tracer used in a wide range of fields including archaeology, ecology, food and forensic sciences. These applications are based on the principle that the Sr isotopic ratios of natural materials reflect the sources of strontium available during their formation. A major constraint for current studies is the lack of robust reference maps to evaluate the source of strontium isotope ratios measured in the samples. Here we provide a new dataset of bioavailable Sr isotope ratios for the major geologic units of France, based on plant and soil samples (Pangaea data repository doi:10.1594/PANGAEA.819142). The IRHUM (Isotopic Reconstruction of Human Migration) database is a web platform to access, explore and map our dataset. The database provides the spatial context and metadata for each sample, allowing the user to evaluate the suitability of the sample for their specific study. In addition, it allows users to upload and share their own datasets and data products, which will enhance collaboration across the different research fields. This article describes the sampling and analytical methods used to generate the dataset and how to use and access of the dataset through the IRHUM database. Any interpretation of the isotope dataset is outside the scope of this publication.
Performance Characterization of Swept Ramp Obstacle Fields in Pulse Detonation Applications
2010-03-01
field of practical obstacle geometries. 15. NUMBER OF PAGES 97 14. SUBJECT TERMS Pulse Detonation , PDE , Transient Plasma Ignition, TPI, Swept... Detonation Transition NI - National Instruments NPS - Naval Postgraduate School PDC - Pulse Detonation Combustor PDE - Pulse Detonation Engine...with incredible grace. xvi THIS PAGE INTENTIONALLY LEFT BLANK 1 I. INTRODUCTION Pulse detonation engines ( PDE ) continue to be explored due to
Radio Identification of Millimeter-Bright Galaxies Detected in the AzTEC/ASTE Blank Field Survey
NASA Astrophysics Data System (ADS)
Hatsukade, Bunyo; Kohno, Kotaro; White, Glenn; Matsuura, Shuji; Hanami, Hitoshi; Shirahata, Mai; Nakanishi, Kouichiro; Hughes, David; Tamura, Yoichi; Iono, Daisuke; Wilson, Grant; Yun, Min
2008-10-01
We propose a deep 1.4-GHz imaging of millimeter-bright sources in the AzTEC/ASTE 1.1-mm blank field survey of AKARI Deep Field-South. The AzTEC/ASTE uncovered 37 sources, which are possibly at z > 2. We have obtained multi-wavelength data in this field, but the large beam size of AzTEC/ASTE (30 arcsec) prevents us from identifying counterparts. The aim of this proposal is to identify radio counterparts with higher-angular resolution. This enables us (i) To identifying optical/IR counterparts. It enables optical spectroscopy to determine precise redshifts, allowing us to derive SFRs, luminosity functions, clustering properties, mass of dark matter halos, etc. (ii) To constrain luminosity evolutions of SMGs by comparing of 1.4-GHz number counts (and luminosity functions) with luminosity evolution models. (iii) To estimate photometric redshifts from 1.4-GHz and 1.1-mm data using the radio-FIR flux correlation. In case of non-detection, we can put deep lower limits (3 sigma limit of z > 3). These information lead to the study of evolutionary history of SMGs, their relationship with other galaxy populations, contribution to the cosmic star formation history and the infrared background.
NASA Astrophysics Data System (ADS)
Zeballos, M.; Hughes, D. H.; Aretxaga, I.; Wilson, G.
2011-10-01
We present an analysis of the number density and spatial distribution of the population of millimetre galaxies (MMGs) towards 17 high-z active galaxies using 1.1 mm observations taken with the AzTEC camera on the Atacama Submillimeter Telescope Experiment (ASTE) and the James Clerk Maxwell Telescope (JCMT). The sample allows us to study the properties of MMGs in protocluster environments and compare them to the population in blank (unbiased) fields. The goal is to identify if these biased environments are responsible for differences in the number and distribution of dust-obscured star-forming galaxies and whether these changes support the suggestion that MMGs are the progenitors of massive (elliptical) galaxies we see today in the centre of rich clusters.
Reddy, Michael M.; Gunther, Charmaine D.
2012-01-01
Samples were collected from groundwater wells in and about the city of Las Vegas, Nevada, and were analyzed for selected major, minor and trace constituents. Analyses of blank and reference samples are summarized as mean and standard deviation values for all positive results.
Gray, James L; Borch, Thomas; Furlong, Edward T; Davis, Jessica G; Yager, Tracy J; Yang, Yun-Ya; Kolpin, Dana W
2017-02-15
The presence of anthropogenic contaminants such as antimicrobials, flame-retardants, and plasticizers in runoff from agricultural fields applied with municipal biosolids may pose a potential threat to the environment. This study assesses the potential for rainfall-induced runoff of 69 anthropogenic waste indicators (AWIs), widely found in household and industrial products, from biosolids amended field plots. The agricultural field containing the test plots was treated with biosolids for the first time immediately prior to this study. AWIs present in soil and biosolids were isolated by continuous liquid-liquid extraction and analyzed by full-scan gas chromatography/mass spectrometry. Results for 18 AWIs were not evaluated due to their presence in field blank QC samples, and another 34 did not have sufficient detection frequency in samples to analyze trends in data. A total of 17 AWIs, including 4-nonylphenol, triclosan, and tris(2-butoxyethyl)phosphate, were present in runoff with acceptable data quality and frequency for subsequent interpretation. Runoff samples were collected 5days prior to and 1, 9, and 35days after biosolids application. Of the 17 AWIs considered, 14 were not detected in pre-application samples, or their concentrations were much smaller than in the sample collected one day after application. A range of trends was observed for individual AWI concentrations (typically from 0.1 to 10μg/L) over the course of the study, depending on the combination of partitioning and degradation mechanisms affecting each compound most strongly. Overall, these results indicate that rainfall can mobilize anthropogenic contaminants from biosolids-amended agricultural fields, directly to surface waters and redistribute them to terrestrial sites away from the point of application via runoff. For 14 of 17 compounds examined, the potential for runoff remobilization during rainstorms persists even after three 100-year rainstorm-equivalent simulations and the passage of a month. Copyright © 2016. Published by Elsevier B.V.
Gray, James L.; Borch, Thomas; Furlong, Edward T.; Davis, Jessica; Yager, Tracy; Yang, Yun-Ya; Kolpin, Dana W.
2017-01-01
The presence of anthropogenic contaminants such as antimicrobials, flame-retardants, and plasticizers in runoff from agricultural fields applied with municipal biosolids may pose a potential threat to the environment. This study assesses the potential for rainfall-induced runoff of 69 anthropogenic waste indicators (AWIs), widely found in household and industrial products, from biosolids amended field plots. The agricultural field containing the test plots was treated with biosolids for the first time immediately prior to this study. AWIs present in soil and biosolids were isolated by continuous liquid-liquid extraction and analyzed by full-scan gas chromatography/mass spectrometry. Results for 18 AWIs were not evaluated due to their presence in field blank QC samples, and another 34 did not have sufficient detection frequency in samples to analyze trends in data. A total of 17 AWIs, including 4-nonylphenol, triclosan, and tris(2-butoxyethyl)phosphate, were present in runoff with acceptable data quality and frequency for subsequent interpretation. Runoff samples were collected 5 days prior to and 1, 9, and 35 days after biosolids application. Of the 17 AWIs considered, 14 were not detected in pre-application samples, or their concentrations were much smaller than in the sample collected one day after application. A range of trends was observed for individual AWI concentrations (typically from 0.1 to 10 μg/L) over the course of the study, depending on the combination of partitioning and degradation mechanisms affecting each compound most strongly. Overall, these results indicate that rainfall can mobilize anthropogenic contaminants from biosolids-amended agricultural fields, directly to surface waters and redistribute them to terrestrial sites away from the point of application via runoff. For 14 of 17 compounds examined, the potential for runoff remobilization during rainstorms persists even after three 100-year rainstorm-equivalent simulations and the passage of a month.
Offenberg, John H; Lewandowski, Michael; Edney, Edward O; Kleindienst, Tadeusz E; Jaoui, Mohammed
2007-05-01
Organic carbon (OC) was measured semicontinuously in laboratory experiments of steady-state secondary organic aerosol formed by hydrocarbon + nitrogen oxide irradiations. Examination of the mass of carbon measured on the filter for various sample volumes reveals a systematic offset that is not observed when performing an instrumental blank. These findings suggest that simple subtraction of instrumental blanks determined as the standard analysis without sample collection (i.e., by cycling the pump and valves yet filtering zero liters of air followed by routine chemical analysis) from measured concentrations may be inadequate. This may be especially true for samples collected through the filtration of small air volumes wherein the influence of the systematic offset is greatest. All of the experiments show that filtering a larger volume of air minimizes the influence of contributions from the systematic offset. Application of these results to measurements of ambient concentrations of carbonaceous aerosol suggests a need for collection of sufficient carbon mass to minimize the relative influence of the offset signal.
FRONTIER FIELDS: HIGH-REDSHIFT PREDICTIONS AND EARLY RESULTS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coe, Dan; Bradley, Larry; Zitrin, Adi, E-mail: DCoe@STScI.edu
2015-02-20
The Frontier Fields program is obtaining deep Hubble and Spitzer Space Telescope images of new ''blank'' fields and nearby fields gravitationally lensed by massive galaxy clusters. The Hubble images of the lensed fields are revealing nJy sources (AB mag > 31), the faintest galaxies yet observed. The full program will transform our understanding of galaxy evolution in the first 600 million years (z > 9). Previous programs have yielded a dozen or so z > 9 candidates, including perhaps fewer than expected in the Ultra Deep Field and more than expected in shallower Hubble images. In this paper, we present high-redshift (z >more » 6) number count predictions for the Frontier Fields and candidates in three of the first Hubble images. We show the full Frontier Fields program may yield up to ∼70 z > 9 candidates (∼6 per field). We base this estimate on an extrapolation of luminosity functions observed between 4 < z < 8 and gravitational lensing models submitted by the community. However, in the first two deep infrared Hubble images obtained to date, we find z ∼ 8 candidates but no strong candidates at z > 9. We defer quantitative analysis of the z > 9 deficit (including detection completeness estimates) to future work including additional data. At these redshifts, cosmic variance (field-to-field variation) is expected to be significant (greater than ±50%) and include clustering of early galaxies formed in overdensities. The full Frontier Fields program will significantly mitigate this uncertainty by observing six independent sightlines each with a lensing cluster and nearby blank field.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
VISWANATH, R.S.
This data package presents sampling data and analytical results from the September 22 and 27, 1999, headspace vapor sampling of Hanford Site Tank 241-2-361 during sludge core removal. The Lockheed Martin Hanford Corporation (LMHC) sampling team collected the samples and Waste Management Laboratory (WML) analyzed the samples in accordance with the requirements specified in the 241-2361 Sludge Characterization Sampling and Analysis Plan, (SAP), HNF-4371, Rev. 1, (Babcock and Wilcox Hanford Corporation, 1999). Six SUMMA{trademark} canister samples were collected on each day (1 ambient field blank and 5 tank vapor samples collected when each core segment was removed). The samples weremore » radiologically released on September 28 and October 4, 1999, and received at the laboratory on September 29 and October 6, 1999. Target analytes were not detected at concentrations greater than their notification limits as specified in the SAP. Analytical results for the target analytes and tentatively identified compounds (TICs) are presented in Section 2.2.2 starting on page 2B-7. Three compounds identified for analysis in the SAP were analyzed as TICs. The discussion of this modification is presented in Section 2.2.1.2.« less
Concentrations of the Allelochemical (+/-)-catechin IN Centaurea maculosa soils.
Perry, Laura G; Thelen, Giles C; Ridenour, Wendy M; Callaway, Ragan M; Paschke, Mark W; Vivanco, Jorge M
2007-12-01
The phytotoxin (+/-)-catechin has been proposed to mediate invasion and autoinhibition by the Eurasian plant Centaurea maculosa (spotted knapweed). The importance of (+/-)-catechin to C. maculosa ecology depends in part on whether sufficient catechin concentrations occur at appropriate times and locations within C. maculosa soil to influence neighboring plants. Previous research on catechin in C. maculosa soils has yielded conflicting results, with some studies finding high soil catechin concentrations and other, more recent studies finding little or no catechin in field soils. Here, we report the most extensive study of soil catechin concentrations to date. We examined soil catechin concentrations in 402 samples from 11 C. maculosa sites in North America sampled in consecutive months over 1 yr, excluding winter months. One site was sampled on seven dates, another was sampled twice, and the remaining nine sites were each sampled once on a range of sampling dates. Methods used were similar to those with which we previously measured high soil catechin concentrations. We detected catechin only in the site that was sampled on seven dates and only on one sampling date in that site (May 16 2006), but in all samples collected on that date. The mean soil catechin concentration on that date was 0.65 +/- 0.45 (SD) mg g(-1), comparable to previously reported high concentrations. There are a number of possible explanations for the infrequency with which we detected soil catechin in this work compared to previous studies. Differences in results could reflect spatial and temporal variation in catechin exudation or degradation, as we examined different sites in a different year from most previous studies. Also, large quantities of catechin were detected in blanks for two sampling periods in the present study, leading us to discard those data. This contamination suggests that previous reports of high catechin concentrations that did not include blanks should be viewed with caution. Our results suggest that pure catechin is only rarely present in C. maculosa bulk soils. Thus, although catechin may play a role in C. maculosa invasion, the infrequency of soil catechin that we determined in this study suggests that we cannot be as certain of its role as previous reports of high soil catechin concentrations suggested.
Martin, Jeffrey D.; Norman, Julia E.; Sandstrom, Mark W.; Rose, Claire E.
2017-09-06
U.S. Geological Survey monitoring programs extensively used two analytical methods, gas chromatography/mass spectrometry and liquid chromatography/mass spectrometry, to measure pesticides in filtered water samples during 1992–2012. In October 2012, the monitoring programs began using direct aqueous-injection liquid chromatography tandem mass spectrometry as a new analytical method for pesticides. The change in analytical methods, however, has the potential to inadvertently introduce bias in analysis of datasets that span the change.A field study was designed to document performance of the new method in a variety of stream-water matrices and to quantify any potential changes in measurement bias or variability that could be attributed to changes in analytical methods. The goals of the field study were to (1) summarize performance (bias and variability of pesticide recovery) of the new method in a variety of stream-water matrices; (2) compare performance of the new method in laboratory blank water (laboratory reagent spikes) to that in a variety of stream-water matrices; (3) compare performance (analytical recovery) of the new method to that of the old methods in a variety of stream-water matrices; (4) compare pesticide detections and concentrations measured by the new method to those of the old methods in a variety of stream-water matrices; (5) compare contamination measured by field blank water samples in old and new methods; (6) summarize the variability of pesticide detections and concentrations measured by the new method in field duplicate water samples; and (7) identify matrix characteristics of environmental water samples that adversely influence the performance of the new method. Stream-water samples and a variety of field quality-control samples were collected at 48 sites in the U.S. Geological Survey monitoring networks during June–September 2012. Stream sites were located across the United States and included sites in agricultural and urban land-use settings, as well as sites on major rivers.The results of the field study identified several challenges for the analysis and interpretation of data analyzed by both old and new methods, particularly when data span the change in methods and are combined for analysis of temporal trends in water quality. The main challenges identified are large (greater than 30 percent), statistically significant differences in analytical recovery, detection capability, and (or) measured concentrations for selected pesticides. These challenges are documented and discussed, but specific guidance or statistical methods to resolve these differences in methods are beyond the scope of the report. The results of the field study indicate that the implications of the change in analytical methods must be assessed individually for each pesticide and method.Understanding the possible causes of the systematic differences in concentrations between methods that remain after recovery adjustment might be necessary to determine how to account for the differences in data analysis. Because recoveries for each method are independently determined from separate reference standards and spiking solutions, the differences might be due to an error in one of the reference standards or solutions or some other basic aspect of standard procedure in the analytical process. Further investigation of the possible causes is needed, which will lead to specific decisions on how to compensate for these differences in concentrations in data analysis. In the event that further investigations do not provide insight into the causes of systematic differences in concentrations between methods, the authors recommend continuing to collect and analyze paired environmental water samples by both old and new methods. This effort should be targeted to seasons, sites, and expected concentrations to supplement those concentrations already assessed and to compare the ongoing analytical recovery of old and new methods to those observed in the summer and fall of 2012.
NASA Technical Reports Server (NTRS)
1975-01-01
The trajectory simulation mode (SIMSEP) requires the namelist SIMSEP to follow TRAJ. The SIMSEP contains parameters which describe the scope of the simulation, expected dynamic errors, and cumulative statistics from previous SIMSEP runs. Following SIMSEP are a set of GUID namelists, one for each guidance correction maneuver. The GUID describes the strategy, knowledge or estimation uncertainties and cumulative statistics for that particular maneuver. The trajectory display mode (REFSEP) requires only the namelist TRAJ followed by scheduling cards, similar to those used in GODSEP. The fixed field schedule cards define: types of data displayed, span of interest, and frequency of printout. For those users who can vary the amount of blank common storage in their runs, a guideline to estimate the total MAPSEP core requirements is given. Blank common length is related directly to the dimension of the dynamic state (NDIM) used in transition matrix (STM) computation, and, the total augmented (knowledge) state (NAUG). The values of program and blank common must be added to compute the total decimal core for a CDC 6500. Other operating systems must scale these requirements appropriately.
Optimal Super Dielectric Material
2015-09-01
INTENTIONALLY LEFT BLANK i REPORT DOCUMENTATION PAGE Form Approved OMB No. 0704–0188 Public reporting burden for this collection of information is estimated...containing liquid with dissolved ionic species will form large dipoles, polarized opposite the applied field. Large dipole SDM placed between the...electrodes of a parallel plate capacitor will reduce the net field to an unprecedented extent. This family of materials can form materials with
Kos, Gregor; Lohninger, Hans; Krska, Rudolf
2003-03-01
A novel method, which enables the determination of fungal infection with Fusarium graminearum on corn within minutes, is presented. The ground sample was sieved and the particle size fraction between >250 and 100 microm was used for mid-infrared/attenuated total reflection (ATR) measurements. The sample was pressed onto the ATR crystal, and reproducible pressure was applied. After the spectra were recorded, they were subjected to principle component analysis (PCA) and classified using cluster analysis. Observed changes in the spectra reflected changes in protein, carbohydrate, and lipid contents. Ergosterol (for the total fungal biomass) and the toxin deoxynivalenol (DON; a secondary metabolite) of Fusarium fungi served as reference parameters, because of their relevance for the examination of corn based food and feed. The repeatability was highly improved by sieving prior to recording the spectra, resulting in a better clustering in PCA score/score plots. The developed method enabled the separation of samples with a toxin content of as low as 310 microg/kg from noncontaminated (blank) samples. Investigated concentration ranges were 880-3600 microg/kg for ergosterol and 310-2596 microg/kg for DON. The percentage of correctly classified samples was up to 100% for individual samples compared with a number of blank samples.
Marie-Desvergne, Caroline; Dubosson, Muriel; Mossuz, Véronique Chamel
2018-05-14
In the field of nanoparticle exposure biomonitoring, oxidative stress biomarkers measured in exhaled breath condensate appear promising to detect early respiratory effects in workers handling nanomaterials. However, condensation is known for its poor efficiency in collecting non-volatiles in exhaled breath, leading to the low sensitivity of such measurements. Moreover, to be easily used in field studies on large groups of workers, the collection device must be disposable and convenient. In this study, we have tested a totally disposable commercial device that allows for the easy dry collection of exhaled air after filtration on a patented filter. The suitability and efficiency of the SensAbues (SB) device for collecting 8-isoprostane were evaluated and compared to the RTube (RT). Seven healthy volunteers performed two 15 min collections of exhaled breath, one with the SB and one with the RT. Blank devices were used to determine the background levels induced by each device. 8-isoprostane was measured in all samples using an EIA technique. The levels of 8-isoprostane in the exhaled breath of volunteers after collection with the SB were significantly higher than those after collection with the RT. Moreover, the levels obtained in volunteers with the SB were significantly higher than background levels obtained in blank devices, which was not the case for the RT. This is the first study to report the ability of the SB device to collect and measure 8-isoprostane in exhaled breath. The proposed method offers better sensitivity than a classical collection with the RT device and should be further explored before future application in biomonitoring studies.
WHK Interns Dominate Student Jeopardy Tournament | Poster
A field of study that derives its name from the Latin root for “knowledge”—student interns had a shot at that clue for 200 points in the 10th annual Student Science Jeopardy Tournament, but their minds went blank. Answer: What is Science?
Standardized UXO Technology Demonstration Site Moguls Scoring Record Number 907 (Sky Research, Inc.)
2008-08-01
day timeframe. 3.6 DEMONSTRATOR’S FIELD PERSONNEL Geophysicist: Craig Hyslop Geophysicist: John Jacobsen Geophysicist: Rob Mehl...Conover, John Wiley & Sons, 1980 , pages 144 through 151. APPENDIX F. ABBREVIATIONS F-1 (Page F-2 Blank) ADST = Aberdeen Data Services Team
... inhalants on the rump. Leave this field blank Marijuana Question 1 Tetrahydrocannabinol is: Question 1: Options * A high tech gasoline A chemical in marijuana A brain neurotransmitter A dinosaur in Jurassic Park ...
40 CFR 53.58 - Operational field precision and blank test.
Code of Federal Regulations, 2013 CFR
2013-07-01
... PROGRAMS (CONTINUED) AMBIENT AIR MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II Equivalent... samplers are also subject to a test for possible deposition of particulate matter on inactive filters...
40 CFR 53.58 - Operational field precision and blank test.
Code of Federal Regulations, 2014 CFR
2014-07-01
... PROGRAMS (CONTINUED) AMBIENT AIR MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II Equivalent... samplers are also subject to a test for possible deposition of particulate matter on inactive filters...
40 CFR 53.58 - Operational field precision and blank test.
Code of Federal Regulations, 2010 CFR
2010-07-01
... PROGRAMS (CONTINUED) AMBIENT AIR MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II Equivalent... samplers are also subject to a test for possible deposition of particulate matter on inactive filters...
40 CFR 53.58 - Operational field precision and blank test.
Code of Federal Regulations, 2012 CFR
2012-07-01
... PROGRAMS (CONTINUED) AMBIENT AIR MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II Equivalent... samplers are also subject to a test for possible deposition of particulate matter on inactive filters...
Vavrouš, Adam; Pavloušková, Jana; Ševčík, Václav; Vrbík, Karel; Čabala, Radomír
2016-07-22
Worldwide production of phthalates has led to their undesirable presence in the food chain. Particularly edible oils have become an area of growing concern owing to numerous reported occurrences of phthalates. The analytical methods used in this field face difficulties associated mainly with matrix complexity or phthalate contamination which this study has aimed to describe and resolve. The proposed procedure consisting of liquid-liquid extraction, solid phase extraction and high performance liquid chromatography coupled with tandem mass spectrometry allowed us to analyze simultaneously 6 individual phthalates and 2 phthalate isomeric mixtures. DSC-18 SPE phase was selected for cleanup owing to the most efficient co-extract removal (assessed using high resolution mass spectrometry). Several sources of phthalate contamination were identified, however, the mobile phase was the most serious. The key improvement was achieved by equipping a contamination trap, a 50-mm reverse phase HPLC column, generating a delay between target and mobile phase peaks of the same compounds. RSDs ranging between 2.4 and 16 % confirm good precision and LOQs between 5.5 and 110μgkg(-1) reflect satisfactory blank management. With up to 19 occurrences in 25 analyzed edible oil samples and levels up to 33mgkg(-1), bis(2-ethylhexyl), diisononyl and diisodecyl phthalates were the most important contaminants. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Hughes, David; Ade, P. A.; Aretxaga, I.; Austermann, J.; Bock, J. J.; Dunlop, J.; Gaztanagal, E.; Ivison, R.; Kang, Y.; Kim, S.; Lowenthal, J.; Mauskopf, P.; Montana, A.; Plionis, M.; Scott, K.; Smail, I.; Stevens, J.; Wagg, J.; Wilson, G.; Yun, M.
2006-12-01
Aztec has recently conducted a sensitive, wide-area (300 sq. arcmin's) continuum survey at 1.1mm using the 15-m James Clerk Maxwell Telescope towards 4C41.17, a powerful high-redshift (z 3.8) radio galaxy. These Aztec data, which cover an area >40 times larger than our previous SCUBA survey, reveal a significant over-density of luminous, massive dust-enshrouded galaxies, compared to the results from lower-redshift blank-field sub-mm surveys. One natural interpretation of these new AzTEC data is that the over-density is tracing a large (5 x 5 Mpc) "proto-cluster" structure at z 3.8 associated with the environment of 4C41.17, within which the formation of ultra-luminous starburst galaxies (with rest-frame FIR luminosities >5 x 10^12 Lsun or SFRs > 500 Msun/yr) is taking place at an accelerated rate. Proving the physical association of these massive optically-faint starbursts with the environment of this high-z AGN, and not with the blank-field sub-mm population, for which 50% of the population lies at 1.9 < z < 2.9, remains an outstanding problem. In this presentation we will describe the AzTEC survey, the empirical evidence for this protocluster structure in the early universe, and the planned multi-wavelength follow-up observations of the brightest AzTEC sources towards 4C41.17 that may demonstrate that we are witnessing accelerated galaxy formation, via an increased rate of merging gas-rich galaxies within a rapidly-developing gravitational potential. AzTEC is one of the suite of instruments destined for the 50-m Large Millimeter Telescope (LMT). We will conclude this presentation with a summary of future LMT observations that will trace the evolution of obscured starformation in the dynamic environments towards a significant sample of intermediate and high-z powerful AGN with greater sensitivity and spatial resolution.
VLA AND ALMA IMAGING OF INTENSE GALAXY-WIDE STAR FORMATION IN z ∼ 2 GALAXIES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rujopakarn, W.; Silverman, J. D.; Dunlop, J. S.
2016-12-10
We present ≃0.″4 resolution extinction-independent distributions of star formation and dust in 11 star-forming galaxies (SFGs) at z = 1.3–3.0. These galaxies are selected from sensitive blank-field surveys of the 2′ × 2′ Hubble Ultra-Deep Field at λ = 5 cm and 1.3 mm using the Karl G. Jansky Very Large Array and Atacama Large Millimeter/submillimeter Array. They have star formation rates (SFRs), stellar masses, and dust properties representative of massive main-sequence SFGs at z ∼ 2. Morphological classification performed on spatially resolved stellar mass maps indicates a mixture of disk and morphologically disturbed systems; half of the sample harbor X-ray active galactic nuclei (AGNs),more » thereby representing a diversity of z ∼ 2 SFGs undergoing vigorous mass assembly. We find that their intense star formation most frequently occurs at the location of stellar-mass concentration and extends over an area comparable to their stellar-mass distribution, with a median diameter of 4.2 ± 1.8 kpc. This provides direct evidence of galaxy-wide star formation in distant blank-field-selected main-sequence SFGs. The typical galactic-average SFR surface density is 2.5 M {sub ⊙} yr{sup −1} kpc{sup −2}, sufficiently high to drive outflows. In X-ray-selected AGN where radio emission is enhanced over the level associated with star formation, the radio excess pinpoints the AGNs, which are found to be cospatial with star formation. The median extinction-independent size of main-sequence SFGs is two times larger than those of bright submillimeter galaxies, whose SFRs are 3–8 times larger, providing a constraint on the characteristic SFR (∼300 M {sub ⊙} yr{sup −1}) above which a significant population of more compact SFGs appears to emerge.« less
Standard-Size Blanks for Furniture and Cabinets
Philip A. Araman
1983-01-01
Blanks are rough-dimension parts of a specific size which may be solid or glued up; quality depends on the final use of the material. Standard-size blanks are blanks made to standard thicknesses, lengths, and widths for each desired quality. Blanks in a few standard sizes can be used to make the thousands of different size rough-dimension parts needed by a furniture or...
Quantitative Analysis of Trace Element Impurity Levels in Some Gem-Quality Diamonds
NASA Astrophysics Data System (ADS)
McNeill, J. C.; Klein-Bendavid, O.; Pearson, D. G.; Nowell, G. M.; Ottley, C. J.; Chinn, I.; Malarkey, J.
2009-05-01
Perhaps the most important information required to understand the origin of diamonds is the nature of the fluid that they crystallise from. Constraining the identity of the diamond-forming fluid for high purity gem diamonds is hampered by analytical challenges because of the very low analyte levels involved. Here we use a new ultra- low blank 'off-line' laser ablation method coupled to sector-field ICPMS for the quantitative analysis of fluid-poor gem diamonds. Ten diamonds comprised of both E- and P-type parageneses, from the Premier Mine, South Africa, were analysed for trace element abundances. We assume that the elemental signatures arise from low densities of sub-microscopic fluid inclusions that are analogous to the much higher densities of fluid inclusions commonly found within fluid-rich diamonds exhibiting fibrous growth. Repeatability of multiple (>20) blanks yielded consistently low values so that using the current procedure our limits of quantitation (10-ã blank) are <1pg for most trace elements, except for Sr, Zr, Ba, from 2-9pg and Pb ~30pg. Trace element patterns of the Premier diamond suite show enrichment of LREE over HREE. Abundances broadly decrease with increasing elemental compatibility. As a suite the chondrite normalised diamond patterns show negative Sr, Zr, Ti and Y anomalies and positive U, and Pb anomalies. All sample abundances are very depleted relative to chondrites (0.1 to 0.001X ch). HREE range from 0.1 to 1ppb as do Y, Nb, Cs. Other lighter elements vary from 2-30ppb. Pb reaches several ppb and Ti ranges from ppb values up to 2ppm. No significant difference were observed between the trace element systematics of the eclogitic and peridotitic diamonds. Overall, these initial data have inter-element fractionation patterns similar to those evident from fluid-rich fibrous diamonds and can be sued to infer that both types of diamond-forming fluids share a common origin.
Development of a solenoid pumped in situ zinc analyzer for environmental monitoring
Chapin, T.P.; Wanty, R.B.
2005-01-01
A battery powered submersible chemical analyzer, the Zn-DigiScan (Zn Digital Submersible Chemical Analyzer), has been developed for near real-time, in situ monitoring of zinc in aquatic systems. Microprocessor controlled solenoid pumps propel sample and carrier through an anion exchange column to separate zinc from interferences, add colorimetric reagents, and propel the reaction complex through a simple photometric detector. The Zn-DigiScan is capable of self-calibration with periodic injections of standards and blanks. The detection limit with this approach was 30 ??g L-1. Precision was 5-10% relative standard deviation (R.S.D.) below 100 ??g L-1, improving to 1% R.S.D. at 1000 ??g L-1. The linear range extended from 30 to 3000 ??g L-1. In situ field results were in agreement with samples analyzed by inductively coupled plasma mass spectrometry (ICPMS). This pump technology is quite versatile and colorimetric methods with complex online manipulations such as column reduction, preconcentration, and dilution can be performed with the DigiScan. However, long-term field deployments in shallow high altitude streams were hampered by air bubble formation in the photometric detector. ?? 2005 Elsevier B.V. All rights reserved.
Wang, Bronwen; Mueller, Seth; Stetson, Sarah; Bailey, Elizabeth; Lee, Greg
2011-01-01
We report on the chemical analysis of water samples collected from the Taylor Mountains 1:250,000-scale quadrangle, Alaska. Parameters for which data are reported include pH, conductivity, water temperature, major cation and anion concentrations, trace-element concentrations, and dissolved organic-carbon concentrations. Samples were collected as part of a multiyear U.S. Geological Survey project entitled ?Geologic and Mineral Deposit Data for Alaskan Economic Development.? Data presented here are from samples collected in June and July 2006. The data are being released at this time with minimal interpretation. This is the third release of aqueous geochemical data from this project; aqueous geochemical data from samples collected in 2004 and 2005 were published previously. The data in this report augment but do not duplicate or supersede the previous data release. Site selection was based on a regional sampling strategy that focused on first- and second-order drainages. Water sample site selection was based on landscape parameters that included physiography, wetland extent, lithological changes, and a cursory field review of mineralogy from pan concentrates. Stream water in the Taylor Mountains quadrangle is dominated by bicarbonate (HCO3-), although in a few samples more than 50 percent of the anionic charge can be attributed to sulfate (SO42-). The major-cation chemistry ranges from Ca2+/Mg2+ dominated to a mix of Ca2+/Mg2+/Na++K+. Generally, good agreement was found between the major cations and anions in the duplicate samples. Many trace elements in these samples were at or near the analytical method detection limit, but good agreement was found between duplicate samples for elements with detectable concentrations. All field blank major-ion and trace-element concentrations were below detection.
1989-06-01
field width, it will be padded on the left (or right, if the left adjustment indicator has been given) to make up the field width. The padding character...is blank (space) normally, and zero if the field width was specified with a leading zero (this zero does not imply an octal field width). 25 " a...unsigned octal notation (without a leading zero ). ’x The argument is coverted to unsigned hexadecimal notation (without a leading Ox). * u The argument is
NASA Astrophysics Data System (ADS)
German, C. R.; Connelly, D. P.; Prien, R. D.; Yoerger, D.; Jakuba, M.; Bradley, A.; Shank, T. J.; Edmonds, H. N.; Langmuir, C. H.
2004-12-01
Less than one quarter of the global ridge-crest has yet received even cursory investigation for the presence or absence of hydrothermal activity. To improve exploration efficiency, particularly at high latitudes, new methodologies independent of tethered vehicles are required. To that end, we have begun the use of in situ chemical sensors allied to the increasing capabilities of autonomous underwater vehicles. Here, we present first results from our most recent efforts aboard the second R2K cruise to the Lau Basin (C.Langmuir, PI; Autumn 2004) to (a) map non-buoyant hydrothermal plumes, (b) intercept buoyant hydrothermal plumes and (c) locate and image novel hydrothermal fields on the seafloor. The AUV used for this work is ABE and the sensors deployed are direct extensions of the in situ Fe/Mn sensor deployed previously on SOC's AUTOSUB to investigate seasonally-reducing waters in Loch Etive, NW Scotland. Each in situ instrument comprises an electronics package that contains a tattletale control system with a flash memory card for on-board logging and a chemical manifold, consisting of a series of valves, pumps and a colorimetric cell. Analysis of iron is enabled by the determination of the coloured complex formed between iron II and ferrozine, manganese uses the colour change of PAN in the presence of reduced manganese. The system includes capacity for switching between sample, blank and two on-board samples for "in flight" calibrations with blanks and standards held in medical bags, outside of the pressure-balanced manifold, to attain in situ water-column temperatures. An in-line filter prevents large particle clogging and detection limits for both iron II and manganese II are ca.2nM.
Direct Electric Field Visualization in Semiconductor Planar Structures
2006-12-01
electrical signal . The spectral response is determined by the detector characteristics and the operating temperature. The sensitivity of the material used ...to the Office of Management and Budget, Paperwork Reduction Project (0704-0188) Washington DC 20503. 1. AGENCY USE ONLY (Leave blank) 2. REPORT...words) A new technique for imaging the 2D transport of free charge in semiconductor structures is used to directly map electric field distributions
NASA Astrophysics Data System (ADS)
Willmes, M.; McMorrow, L.; Kinsley, L.; Armstrong, R.; Aubert, M.; Eggins, S.; Falguères, C.; Maureille, B.; Moffat, I.; Grün, R.
2014-03-01
Strontium isotope ratios (87Sr / 86Sr) are a key geochemical tracer used in a wide range of fields including archaeology, ecology, food and forensic sciences. These applications are based on the principle that the Sr isotopic ratios of natural materials reflect the sources of strontium available during their formation. A major constraint for current studies is the lack of robust reference maps to evaluate the source of strontium isotope ratios measured in the samples. Here we provide a new data set of bioavailable Sr isotope ratios for the major geologic units of France, based on plant and soil samples (Pangaea data repository doi:10.1594/PANGAEA.819142). The IRHUM (Isotopic Reconstruction of Human Migration) database is a web platform to access, explore and map our data set. The database provides the spatial context and metadata for each sample, allowing the user to evaluate the suitability of the sample for their specific study. In addition, it allows users to upload and share their own data sets and data products, which will enhance collaboration across the different research fields. This article describes the sampling and analytical methods used to generate the data set and how to use and access the data set through the IRHUM database. Any interpretation of the isotope data set is outside the scope of this publication.
2011-01-01
All of the samples were analyzed in SIM. By comparing the EIC’s (See Appendix) of the MS (for sample EML 091524) and Sample EML091524 it can be...of detection. 25 Blank 26 ACRONYMS amu BFB BME CCV CTC CTF CVAA CVAO CWM DoD ECBC EIC EICP EML EPA GC HD HUMMA IB ICV IOP L
Freitas, João Carlos D; Sarkis, Jorge E Souza; Negrini Neto, Osvaldo; Viebig, Sônia Bocamino
2012-03-01
During criminal investigations involving firearms, the detection of gunshot residues (GSRs) is one of the most important evidences. In the present study, a new method to identify trace evidences of GSRs, deposited around the bullet entrance hole, in different types of fabrics used as targets, is described. The experiments were carried out using a 0.38-inch caliber revolver, and 9-mm and 0.40-inch caliber pistols. Testimonies of 2.25 cm(2) of the fabrics were cut around the bullet entrance and digested with 10% nitric acid. Antimony, barium, and lead were analyzed in the remaining solution using a sector field inductively coupled plasma mass spectrometer. The concentrations of the elements were detected at levels up to few microgram per square centimeter. The use of ternary graphics allowed us to identify specific patterns of distribution for blank samples and the clear distinction between the revolver and pistols used. © 2011 American Academy of Forensic Sciences.
Presley, Todd K.; Jamison, Marcael T.J.
2010-01-01
Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. The program is designed to assess the effects of highway runoff and urban runoff collected by the H-1 storm drain on the Manoa-Palolo Drainage Canal. This report summarizes rainfall, discharge, and water-quality data collected between July 1, 2009, and June 30, 2010. As part of this program, rainfall and continuous discharge data were collected at the H-1 storm drain. During the year, sampling strategy and sample processing methods were modified to improve the characterization of the effects of discharge from the storm drain on the Manoa-Palolo Drainage Canal. During July 1, 2009, to February 1, 2010, samples were collected from only the H-1 storm drain. Beginning February 2, 2010, samples were collected simultaneously from the H-1 storm drain and the Manoa-Palolo Drainage Canal at a location about 50 feet upstream of the discharge point of the H-1 storm drain. Three storms were sampled during July 1, 2009, to June 30, 2010. All samples were collected using automatic samplers. For the storm of August 12, 2009, grab samples (for oil and grease, and total petroleum hydrocarbons) and a composite sample were collected. The composite sample was analyzed for total suspended solids, nutrients, and selected dissolved and total (filtered and unfiltered) trace metals (cadmium, chromium, nickel, copper, lead, and zinc). Two storms were sampled in March 2010 at the H-1 storm drain and from the Manoa-Palolo Drainage Canal. Two samples were collected during the storm of March 4, 2010, and six samples were collected during the storm of March 8, 2010. These two storms were sampled using the modified strategy, in which discrete samples from the automatic sampler were processed and analyzed individually, rather than as a composite sample, using the simultaneously collected samples from the H-1 storm drain and from the Manoa-Palolo Drainage Canal. The discrete samples were analyzed for some or all of the following constituents: total suspended solids, nutrients, oil and grease, and selected dissolved (filtered) trace metals (cadmium, chromium, nickel, copper, lead, and zinc). Five quality-assurance/quality-control samples were analyzed during the year. These samples included one laboratory-duplicate, one field-duplicate, and one matrix-spike sample prepared and analyzed with the storm samples. In addition, two inorganic blank-water samples, one sample at the H-1 storm drain and one sample at the Manoa-Palolo Drainage Canal, were collected by running the blank water (water purified of all inorganic constituents) through the sampling and processing systems after cleaning automatic sampler lines to verify that the sampling lines were not contaminated.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 3 2013-01-01 2013-01-01 false Blank spaces. 201.35 Section 201.35 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards... REGULATIONS Labeling in General § 201.35 Blank spaces. Blank spaces on the label shall be deemed to imply the...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 3 2010-01-01 2010-01-01 false Blank spaces. 201.35 Section 201.35 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards... REGULATIONS Labeling in General § 201.35 Blank spaces. Blank spaces on the label shall be deemed to imply the...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 3 2014-01-01 2014-01-01 false Blank spaces. 201.35 Section 201.35 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards... REGULATIONS Labeling in General § 201.35 Blank spaces. Blank spaces on the label shall be deemed to imply the...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 3 2012-01-01 2012-01-01 false Blank spaces. 201.35 Section 201.35 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards... REGULATIONS Labeling in General § 201.35 Blank spaces. Blank spaces on the label shall be deemed to imply the...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 3 2011-01-01 2011-01-01 false Blank spaces. 201.35 Section 201.35 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards... REGULATIONS Labeling in General § 201.35 Blank spaces. Blank spaces on the label shall be deemed to imply the...
NASA Astrophysics Data System (ADS)
Jaeschke, W.; Beltz, N.; Haunold, W.; Krischke, U.
1997-07-01
During the Gas-Phase Sulfur Intercomparison Experiment (GASIE) in 1994 an analytical system for measuring sulfur dioxide mixing ratios at low parts per trillion (pptv) levels was employed. It is based on the absorption of SO2 on a tetrachloromercurate(II)-impregnated filter. The subsequent analysis uses a chemiluminescence reaction by treating the resulting disulfitomercurate(II) complex with an acidic cerium sulfate solution. An improved sampling device has been introduced that increases the maximum sampling volume from 200 L to 500 L. It is also possible to determine the blank value accurately for each sample. The absorption efficiency of the sampling system is 98.7±6.4% at a nominal flow rate of 10 L/min. The calculated (3σ) detection limit is 3±1 pptv SO2. The sample solution is stable for up to 30 days, which allows the samples to be safely stored or shipped before analysis. This permits the use of a sensitive, compact, and reliable sampling system in the field with subsequent analysis under optimal conditions in the laboratory. A continuous flow chemiluminescence (CFCL) analyzer for on-line measurements is also presented. The system is based on the same chemical principles as the described filter technique.
Code of Federal Regulations, 2013 CFR
2013-07-01
... that the analyte concentration is greater than zero and is determined from analysis of a sample in a given matrix containing the analyte. Scope and Application This procedure is designed for applicability to a wide variety of sample types ranging from reagent (blank) water containing analyte to wastewater...
Code of Federal Regulations, 2014 CFR
2014-07-01
... that the analyte concentration is greater than zero and is determined from analysis of a sample in a given matrix containing the analyte. Scope and Application This procedure is designed for applicability to a wide variety of sample types ranging from reagent (blank) water containing analyte to wastewater...
Code of Federal Regulations, 2011 CFR
2011-07-01
... that the analyte concentration is greater than zero and is determined from analysis of a sample in a given matrix containing the analyte. Scope and Application This procedure is designed for applicability to a wide variety of sample types ranging from reagent (blank) water containing analyte to wastewater...
da Silva, Leila Picolli; Ciocca, Maria de Lourdes Santorio; Furlong, Eliana Badiale
2003-12-01
The precision attributes and use of the enzymatic-gravimetric method of Prosky et al. (1992) (AOAC 985.29) were evaluated using corn (BR 5202 Pampa) and oat (UFRGS 15) samples. The effect of laboratory batches carried out in different days were evaluated in six laboratory batches, using for each material one duplicate for total fiber (FT) determination, one duplicate for insoluble fiber (FI) determination and blank ones for FT and for FI (both in duplicate). In order to characterize repetitive aspects, five other FT and FI determinations added to each sample were evaluated, summing up 11 data. The low coefficients of variation in the first six batches were considered acceptable as an expression of expected total intralaboratory variation. The repetitive of the method was considered good for FT determinations (CVs < 10%). However, in the FI determination a high frequency of negative values of ash and blanks was found, impairing the repetitive aspects evaluation. The magnitude of the total gravimetric corrections varies with the kind of the sample and is especially influenced by the protein content.
Pomelova, V G; Osin, N S
2007-01-01
This literature review is dedicated to prospects of the use of whole blood dried on special filter paper as a source of biological material for human health and environmental population studies. Evident advantages of this low-invasive approach include the following: it is easy to take a blood sample from a patient's finger ofa neonate's heel; the cost of sampling as well as transportation and storage of samples is low; paper blanks are safe to manipulate with and convenient to mail in sealed plastic packages. Many analytes, such as DNA, become more stable after drying, which allows for the detection of phenotypic and genotypic markers, as well as multiple gene mutations by multiplex DNA amplification. Modern diagnostic techniques make it possible to detect a wide spectrum of biomarkers characterizing the condition of the endocrine, cardiovascular, reproductive, and immune systems of the organism in a single drop of blood. This allows considering paper blanks with dry blood the key component of multilevel interdisciplinary population studies on neonatal screening, disease spread surveillance, seroepidemiological monitoring, and ecological and genetic research.
28 CFR 51.28 - Supplemental contents.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Information Processing Standards (FIPS-55) code. (v) Census tracts shall be left justified, and census blocks shall be left justified and blank filled if less than four characters. (vi) Unused plan fields shall be... affected, containing the following information: (1) The prior and new boundaries of the voting unit or...
Oblinger, Carolyn J.
2004-01-01
The Triangle Area Water Supply Monitoring Project was initiated in October 1988 to provide long-term water-quality data for six area water-supply reservoirs and their tributaries. In addition, the project provides data that can be used to determine the effectiveness of large-scale changes in water-resource management practices, document differences in water quality among water-supply types (large multiuse reservoir, small reservoir, run-of-river), and tributary-loading and in-lake data for water-quality modeling of Falls and Jordan Lakes. By September 2001, the project had progressed in four phases and included as many as 34 sites (in 1991). Most sites were sampled and analyzed by the U.S. Geological Survey. Some sites were already a part of the North Carolina Division of Water Quality statewide ambient water-quality monitoring network and were sampled by the Division of Water Quality. The network has provided data on streamflow, physical properties, and concentrations of nutrients, major ions, metals, trace elements, chlorophyll, total organic carbon, suspended sediment, and selected synthetic organic compounds. Project quality-assurance activities include written procedures for sample collection, record management and archive, collection of field quality-control samples (blank samples and replicate samples), and monitoring the quality of field supplies. In addition to project quality-assurance activities, the quality of laboratory analyses was assessed through laboratory quality-assurance practices and an independent laboratory quality-control assessment provided by the U.S. Geological Survey Branch of Quality Systems through the Blind Inorganic Sample Project and the Organic Blind Sample Project.
Benthic Flux Sampling Device. Operations, Methods, and Procedures
1993-02-01
nitric acid (HNO3) overnight, then rinse with D.I. water. When in doubt, consult with the chemist for proper cleaning protocols. CHARGE BATTERIES...sis being performed. The system will be flushed with methanol to remove organic com- pounds and with nitric acid to remove metals. The nitric acid ... acid -washed, 500-me Teflon (TFE) sampling bottles aboard the BFSD. After each deployment, blank ferrules are fitted in place of the sampling lines and
From Cosmic Dusk till Dawn with RELICS
NASA Astrophysics Data System (ADS)
Bradac, Marusa
When did galaxies start forming stars? What is the role of distant galaxies in galaxy formation models and the epoch of reionization? What are the conditions in typical lowmass, star-forming galaxies at z 4? Why is galaxy evolution dependent on environment? Recent observations indicate several critical puzzles in studies that address these questions. Chief among these, galaxies might have started forming stars earlier than previously thought (<400Myr after the Big Bang) and their star formation history differs from what is predicted from simulations. Furthermore, the details of the mechanisms that regulate star formation and morphological transformation in dense environments are still unknown. To solve these puzzles of galaxy evolution, we will use 41 galaxy clusters from the RELICS program (Reionization Lensing Cluster Survey) that are among the most powerful cosmic telescopes. Their magnification will allow us to study stellar properties of a large number of galaxies all the way to the reionization era. Accurate knowledge of stellar masses, ages, and star formation rates (SFRs) requires measuring both rest-frame UV and optical light, which only Spitzer can probe at z>0.5-11 for a sufficiently large sample of typical galaxies. This program will combine Spitzer imaging from two large programs, Director Discretionary Time (DDT) and the SRELICS program led by the PI.The main challenge in a study such as this is the capability to perform reliable photometry in crowded fields. Our team recently helped develop TPHOT, which is a much improved and much faster version of previously available codes. TPHOT is specifically designed to extract fluxes in crowded fields with very different PSFs. We will combine Spitzer photometry with ground based imaging and spectroscopy to obtain robust measurements of galaxy star formation rates, stellar masses, and stellar ages. This program will be a crucial legacy complement to previous Spitzer/IRAC deep blank field surveys and cluster studies, and will open up new parameter space by probing intrinsically fainter objects than most current surveys with a significantly improved sample variance over deep field surveys. It will allow us to study the properties (e.g. SFRs and stellar masses) of a large number of galaxies (200 at z=6-10), thus meeting our goal of reconstructing the cosmic SFR density with sufficient precision to better understand the role of galaxies in the reionization process. We will measure the presence (or absence) of established stellar populations with Spitzer for the largest sample to date. Furthermore this proposal will allow us to study the SFRs of the intrinsically faint (and magnified) intermediate redshift (z 4) galaxies, as well as the stellar mass function of z=0.3-0.7 galaxy members of our cluster sample, thereby expanding our understanding of star formation from reionization to the epoch of galaxy formation and dense environments. Many of the science goals of this proposal are main science drivers for JWST. Due to magnification our effective depth and resolution match those of the JWST blank fields and affords us a sneak preview of JWST sources with Spitzer now. This program will thus provide a valuable test-bed for simulations, observation planning and source selection just in time for JWST Cycle 1.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 7 S Strike Price. 51 1 AN Exercise Style. 52 7 N Long—Buy—Stopped. 59 7 N Short—Sell—Issued. 66 5 AN... futures, the field is left blank. (x) Exercise style. Valid values for this field are “A” for American style options, i.e., those that can be exercised at any time during the life of the options; and “E” for...
Method of Making Lightweight, Single Crystal Mirror
NASA Technical Reports Server (NTRS)
Bly, Vincent T. (Inventor)
2015-01-01
A method of making a mirror from a single crystal blank may include fine grinding top and bottom surfaces of the blank to be parallel. The blank may then be heat treated to near its melting temperature. An optical surface may be created on an optical side of the blank. A protector may be bonded to the optical surface. With the protector in place, the blank may be light weighted by grinding a non-optical surface of the blank using computer controlled grinding. The light weighting may include creating a structure having a substantially minimum mass necessary to maintain distortion of the mirror within a preset limit. A damaged layer of the non-optical surface caused by light weighting may be removed with an isotropic etch and/or repaired by heat treatment. If an oxide layer is present, the entire blank may then be etched using, for example, hydrofluoric acid. A reflecting coating may be deposited on the optical surface.
Understanding EUV mask blank surface roughness induced LWR and associated roughness requirement
NASA Astrophysics Data System (ADS)
Yan, Pei-Yang; Zhang, Guojing; Gullikson, Eric M.; Goldberg, Ken A.; Benk, Markus P.
2015-03-01
Extreme ultraviolet lithography (EUVL) mask multi-layer (ML) blank surface roughness specification historically comes from blank defect inspection tool requirement. Later, new concerns on ML surface roughness induced wafer pattern line width roughness (LWR) arise. In this paper, we have studied wafer level pattern LWR as a function of EUVL mask surface roughness via High-NA Actinic Reticle Review Tool. We found that the blank surface roughness induced LWR at current blank roughness level is in the order of 0.5nm 3σ for NA=0.42 at the best focus. At defocus of ±40nm, the corresponding LWR will be 0.2nm higher. Further reducing EUVL mask blank surface roughness will increase the blank cost with limited benefit in improving the pattern LWR, provided that the intrinsic resist LWR is in the order of 1nm and above.
EUVL mask patterning with blanks from commercial suppliers
NASA Astrophysics Data System (ADS)
Yan, Pei-Yang; Zhang, Guojing; Nagpal, Rajesh; Shu, Emily Y.; Li, Chaoyang; Qu, Ping; Chen, Frederick T.
2004-12-01
Extreme Ultraviolet Lithography (EUVL) reflective mask blank development includes low thermal expansion material fabrication, mask substrate finishing, reflective multi-layer (ML) and capping layer deposition, buffer (optional)/absorber stack deposition, EUV specific metrology, and ML defect inspection. In the past, we have obtained blanks deposited with various layer stacks from several vendors. Some of them are not commercial suppliers. As a result, the blank and patterned mask qualities are difficult to maintain and improve. In this paper we will present the evaluation results of the EUVL mask pattering processes with the complete EUVL mask blanks supplied by the commercial blank supplier. The EUVL mask blanks used in this study consist of either quartz or ULE substrates which is a type of low thermal expansion material (LTEM), 40 pairs of molybdenum/silicon (Mo/Si) ML layer, thin ruthenium (Ru) capping layer, tantalum boron nitride (TaBN) absorber, and chrome (Cr) backside coating. No buffer layer is used. Our study includes the EUVL mask blank characterization, patterned EUVL mask characterization, and the final patterned EUVL mask flatness evaluation.
MUTAGENICITY OF TEFLON-COATED GLASS FIBER FILTERS: A POTENTIAL PROBLEM AND SOLUTIONS
Teflon-coated glass fiber filters, used in studies of airborne particulate matter, were tested for mutagenic activity using the Salmonella/mammalian-microsome (Ames) assay. For each sample, eight blank filters were simultaneously extracted with dichloromethane (DCM), and the extr...
Recovery. precision, limits of detection and quantitation, blank levels, calibration linearity, and agreement with certified reference materials were determined for two classes of organic components of airborne particulate matter, polycyclic aromatic hydrocarbons and hopanes usin...
Hydroforming Of Patchwork Blanks — Numerical Modeling And Experimental Validation
NASA Astrophysics Data System (ADS)
Lamprecht, Klaus; Merklein, Marion; Geiger, Manfred
2005-08-01
In comparison to the commonly applied technology of tailored blanks the concept of patchwork blanks offers a number of additional advantages. Potential application areas for patchwork blanks in automotive industry are e.g. local reinforcements of automotive closures, structural reinforcements of rails and pillars as well as shock towers. But even if there is a significant application potential for patchwork blanks in automobile production, industrial realization of this innovative technique is decelerated due to a lack of knowledge regarding the forming behavior and the numerical modeling of patchwork blanks. Especially for the numerical simulation of hydroforming processes, where one part of the forming tool is replaced by a fluid under pressure, advanced modeling techniques are required to ensure an accurate prediction of the blanks' forming behavior. The objective of this contribution is to provide an appropriate model for the numerical simulation of patchwork blanks' forming processes. Therefore, different finite element modeling techniques for patchwork blanks are presented. In addition to basic shell element models a combined finite element model consisting of shell and solid elements is defined. Special emphasis is placed on the modeling of the weld seam. For this purpose the local mechanical properties of the weld metal, which have been determined by means of Martens-hardness measurements and uniaxial tensile tests, are integrated in the finite element models. The results obtained from the numerical simulations are compared to experimental data from a hydraulic bulge test. In this context the focus is laid on laser- and spot-welded patchwork blanks.
Hoffman, G.L.; Fishman, M. J.; Garbarino, J.R.
1996-01-01
Water samples for trace-metal determinations routinely have been prepared in open laboratories. For example, the U.S. Geological Survey method I-3485-85 (Extraction Procedure, for Water- Suspended Sediment) is performed in a laboratory hood on a laboratory bench without any special precautions to control airborne contamination. This method tends to be contamination prone for several trace metals primarily because the samples are transferred, acidified, digested, and filtered in an open laboratory environment. To reduce trace-metal contamination of digested water samples, procedures were established that rely on minimizing sample-transfer steps and using a class-100 clean bench during sample filtration. This new procedure involves the following steps: 1. The sample is acidified with HCl directly in the original water-sample bottle. 2. The water-sample bottle with the cap secured is heated in a laboratory oven. 3. The digestate is filtered in a class-100 laminar-flow clean bench. The exact conditions used (that is, oven temperature, time of heating, and filtration methods) for this digestion procedure are described. Comparisons between the previous U.S Geological Survey open-beaker method I-3485-85 and the new in-bottle procedure for synthetic and field-collected water samples are given. When the new procedure is used, blank concentrations for most trace metals determined are reduced significantly.
Space ten-meter telescope (STMT) - Structural and thermal feasibility study of the primary mirror
NASA Technical Reports Server (NTRS)
Bely, Pierre Y.; Bolton, John F.; Neeck, Steven P.; Tulkoff, Philip J.
1987-01-01
The structural and thermal behavior of a ten-meter primary mirror for a space optical/near-IR telescope in geosynchronous orbit is studied. The glass-type lightweighted mirror is monolithic, of the double arch type, and is supported at only three points. The computer programs SSPTA (thermal), NASTRAN (finite element), and ACCOS V (optical) are used in sequence to determine the temperature, deformation, and optical performance of the mirror. A mirror temperature of 130 K or less appears to be obtainable by purely passive means. With a fused silica or standard Zerodur blank, thermally-induced deformation is unacceptable and cannot be fully corrected by an active secondary mirror over the desired field. Either active thermal control or a blank of lower thermal expansion coefficient would be required.
NASA Astrophysics Data System (ADS)
Wood, Claire M.; Bunce, Robert G. H.; Norton, Lisa R.; Maskell, Lindsay C.; Smart, Simon M.; Scott, W. Andrew; Henrys, Peter A.; Howard, David C.; Wright, Simon M.; Brown, Michael J.; Scott, Rod J.; Stuart, Rick C.; Watkins, John W.
2018-04-01
The Countryside Survey (CS) of Great Britain (GB) provides a unique and statistically robust series of datasets, consisting of an extensive set of repeated ecological measurements at a national scale, covering a time span of 29 years. CS was first undertaken in 1978 to provide a baseline for ecological and land use change monitoring in the rural environment of GB, following a stratified random design, based on 1 km squares. Originally, eight random 1 km squares were drawn from each of 32 environmental classes, thus comprising 256 sample squares in the 1978 survey. The number of these sites increased to 382 in 1984, 506 in 1990, 569 in 1998 and 591 in 2007. Detailed information regarding vegetation types and land use was mapped in all five surveys, allowing reporting by defined standard habitat classifications. Additionally, point and linear landscape features (such as trees and hedgerows) are available from all surveys after 1978. From these stratified, randomly located sample squares, information can be converted into national estimates, with associated error terms. Other data, relating to soils, freshwater and vegetation, were also sampled on analogous dates. However, the present paper describes only the surveys of landscape features and habitats. The resulting datasets provide a unique, comprehensive, quantitative ecological coverage of extent and change in these features in GB. Basic results are presented and their implications discussed. However, much opportunity for further analyses remains. Data from each of the survey years are available via the following DOIs: Landscape area data 1978: https://doi.org/10.5285/86c017ba-dc62-46f0-ad13-c862bf31740e, 1984: https://doi.org/10.5285/b656bb43-448d-4b2c-aade-7993aa243ea3, 1990: https://doi.org/10.5285/94f664e5-10f2-4655-bfe6-44d745f5dca7, 1998: https://doi.org/10.5285/1e050028-5c55-42f4-a0ea-c895d827b824, and 2007: https://doi.org/10.5285/bf189c57-61eb-4339-a7b3-d2e81fdde28d; Landscape linear feature data 1984: https://doi.org/10.5285/a3f5665c-94b2-4c46-909e-a98be97857e5, 1990: https://doi.org/10.5285/311daad4-bc8c-485a-bc8a-e0d054889219, 1998: https://doi.org/10.5285/8aaf6f8c-c245-46bb-8a2a-f0db012b2643 and 2007: https://doi.org/10.5285/e1d31245-4c0a-4dee-b36c-b23f1a697f88, Landscape point feature data 1984: https://doi.org/10.5285/124b872e-036e-4dd3-8316-476b5f42c16e, 1990: https://doi.org/10.5285/1481bc63-80d7-4d18-bcba-8804aa0a9e1b, 1998: https://doi.org/10.5285/ed10944f-40c8-4913-b3f5-13c8e844e153 and 2007: https://doi.org/10.5285/55dc5fd7-d3f7-4440-b8a7-7187f8b0550b.
Sai, Fan; Hong, Miao; Yunfeng, Zhao; Huijing, Chen; Yongning, Wu
2012-02-29
A sensitive method has been developed for the simultaneous determination of residues of 25 β₂-agonists and 23 β-blockers in animal foods by high-performance liquid chromatography coupled with linear ion trap mass spectrometry (HPLC-LIT-MS). This method is based on a new procedure of hydrolysis and extraction by 5% trichloracetic acid, and then cleaned up by mixed strong cation exchange (MCX) cartridges coupled with a novelty cleanup step by methanol. Methanol and 0.1% formic acid were used as mobile phases for gradient elution, while a Supelco Ascentis Express Rp-Amide column was used for LC separation. ESI positive ion scan mode was used with consecutive reaction monitoring (CRM, MS³). Nine β₂-agonists labeled by the deuterium isotope were used as internal standards for quantification. The linear ranges of 48 analytes were from 5 to 200 μg/L; the coefficient of correlation was not less than 0.995. Blank pork muscle, blank liver, and blank kidney were selected as representative matrix for spiked standard recovery test. The recoveries of each compound were in the range of 46.6-118.9%, and the relative standard deviations were in the range of 1.9-28.2%. Decision limits (CCα, α = 0.01) of 48 analytes in muscles, liver, and kidney samples ranged from 0.05 to 0.49 μg/kg, and the detection capability (CCβ, β = 0.05) ranged from 0.13 to 1.64 μg/kg. This method was successfully applied to 110 real animal origin food samples including meat, liver, and kidney of pig and chicken samples.
Olsen, Lisa D.; Spencer, Tracey A.
2000-01-01
The U.S. Geological Survey (USGS) collected 13 surface-water samples and 3 replicates from 5 sites in the West Branch Canal Creek area at Aberdeen Proving Ground from February through August 1999, as a part of an investigation of ground-water contamination and natural attenuation processes. The samples were analyzed for volatile organic compounds, including trichloroethylene, 1,1,2,2-tetrachloroethane, carbon tetrachloride, and chloroform, which are the four major contaminants that were detected in ground water in the Canal Creek area in earlier USGS studies. Field blanks were collected during the sampling period to assess sample bias. Field replicates were used to assess sample variability, which was expressed as relative percent difference. The mean variability of the surface-water replicate analyses was larger (35.4 percent) than the mean variability of ground-water replicate analyses (14.6 percent) determined for West Branch Canal Creek from 1995 through 1996. The higher variability in surface-water analyses is probably due to heterogeneities in the composition of the surface water rather than differences in sampling or analytical procedures. The most frequently detected volatile organic compound was 1,1,2,2- tetrachloroethane, which was detected in every sample and in two of the replicates. The surface-water contamination is likely the result of cross-media transfer of contaminants from the ground water and sediments along the West Branch Canal Creek. The full extent of surface-water contamination in West Branch Canal Creek and the locations of probable contaminant sources cannot be determined from this limited set of data. Tidal mixing, creek flow patterns, and potential effects of a drought that occurred during the sampling period also complicate the evaluation of surface-water contamination.
High speed reflectometer for EUV mask-blanks
NASA Astrophysics Data System (ADS)
Wies, Christian; Lebert, Rainer; Jagle, Bernhard; Juschkin, L.; Sobel, F.; Seitz, H.; Walter, Ronny; Laubis, C.; Scholze, F.; Biel, W.; Steffens, O.
2005-06-01
AIXUV GmbH and partners have developed a high speed Reflectometer for EUV mask-blanks which is fully compliant with the SEMI-standard P38 for EUV-mask-blank metrology. The system has been installed in June 2004 at SCHOTT Lithotec AG. It features high throughput, high lateral and spectral resolution, high reproducibility and low absolute uncertainty. Using AIXUV's EUV-LAMP and debris mitigation, low cost-of-ownership and high availability is expected. The spectral reflectance of up to 3 mask-blanks per hour can be measured with at least 20 spots each. The system is push button-controlled. Results are stored in CSV file format. For a spot size of 0.1x1 mm2, 2000 spectral channels of 1.6 pm bandwidth are recorded from 11.6 nm to 14.8 nm. The reflectance measurement is based on the comparison of the sample under test to two reference mirrors calibrated at the PTB radiometry laboratory at BESSY II. The three reflection spectra are recorded simultaneously. For each spot more than 107 photons are accumulated in about 20 s, providing statistical reproducibility below 0.2% RMS. The total uncertainty is below 0.5% absolute. Wavelength calibration better than 1 pm RMS over the whole spectral range is achieved by reference to NIST published wavelengths of about 100 xenon emission lines. It is consistent with the wavelength of the krypton 3d-5p absorption resonance at 13.5947 nm to better than 2 pm.
High speed reflectometer for EUV mask-blanks
NASA Astrophysics Data System (ADS)
Wies, C.; Lebert, R.; Jaegle, B.; Juschkin, L.; Sobel, F.; Seitz, H.; Walter, R.; Laubis, C.; Scholze, F.; Biel, W.; Steffens, O.
2005-05-01
AIXUV GmbH and partners have developed a high speed Reflectometer for EUV mask-blanks which is fully compliant with the SEMI-standard P38 for EUV-mask-blank metrology. The system has been installed in June 2004 at SCHOTT Lithotec AG. It features high throughput, high lateral and spectral resolution, high reproduci-bility and low absolute uncertainty. Using AIXUV's EUV-LAMP and debris mitigation, low cost-of-ownership and high availability is expected. The spectral reflectance of up to 3 mask-blanks per hour can be measured with at least 20 spots each. The system is push button-controlled. Results are stored in CSV file format. For a spot size of 0.1×1 mm2, 2000 spectral chan-nels of 1.6 pm bandwidth are recorded from 11.6 nm to 14.8 nm. The reflectance measurement is based on the comparison of the sample under test to two reference mirrors calibrated at the PTB radiometry laboratory at BESSY II. The three reflection spectra are recorded simultaneously. For each spot more than 107 photons are ac-cumulated in about 20 s, providing statistical reproducibility below 0.2 % RMS. The total uncertainty is below 0.5 % absolute. Wavelength calibration better than 1 pm RMS over the whole spectral range is achieved by refe-rence to NIST published wavelengths of about 100 xenon emission lines. It is consistent with the wavelength of the krypton 3d-5p absorption resonance at 13.5947 nm to better than 2 pm.
Tank 40 Final SB7b Chemical Characterization Results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bannochie, C. J.
2012-11-06
A sample of Sludge Batch 7b (SB7b) was taken from Tank 40 in order to obtain radionuclide inventory analyses necessary for compliance with the Waste Acceptance Product Specifications (WAPS). The SB7b WAPS sample was also analyzed for chemical composition including noble metals and fissile constituents. At the Savannah River National Laboratory (SRNL) the 3-L Tank 40 SB7b sample was transferred from the shipping container into a 4-L high density polyethylene bottle and solids were allowed to settle over the weekend. Supernate was then siphoned off and circulated through the shipping container to complete the transfer of the sample. Following thoroughmore » mixing of the 3-L sample, a 558 g sub-sample was removed. This sub-sample was then utilized for all subsequent analytical samples. Eight separate aliquots of the slurry were digested, four with HNO{sub 3}/HCl (aqua regia) in sealed Teflon vessels and four with NaOH/Na{sub 2}O{sub 2} (alkali or peroxide fusion) using Zr crucibles. Two Analytical Reference Glass ? 1 (ARG-1) standards were digested along with a blank for each preparation. Each aqua regia digestion and blank was diluted to 1:100 mL with deionized water and submitted to Analytical Development (AD) for inductively coupled plasma ? atomic emission spectroscopy (ICP-AES) analysis, inductively coupled plasma ? mass spectrometry (ICP-MS) analysis, atomic absorption spectroscopy (AA) for As and Se, and cold vapor atomic absorption spectroscopy (CV-AA) for Hg. Equivalent dilutions of the alkali fusion digestions and blank were submitted to AD for ICP-AES analysis. Tank 40 SB7b supernate was collected from a mixed slurry sample in the SRNL Shielded Cells and submitted to AD for ICP-AES, ion chromatography (IC), total base/free OH{sup -}/other base, total inorganic carbon/total organic carbon (TIC/TOC) analyses, and Cs-137 gamma scan. Weighted dilutions of slurry were submitted for IC, TIC/TOC, and total base/free OH-/other base analyses. Activities for U-233, U-235, and Pu-239 were determined from the ICP-MS data for the aqua regia digestions of the Tank 40 WAPS slurry using the specific activity of each isotope. The Pu-241 value was determined from a Pu-238/-241 method.« less
Extracting metalworking fluid aerosol samples in cassettes by provisional ASTM and NIOSH methods.
Harper, Martin
2002-01-01
Recent provisional methods for the determination of metalworking fluid aerosol in workplace air involve a solvent extraction procedure to separate the nonvolatile fraction of the fluid from insoluble material such as metal turnings and dirt. The procedure calls for preweighing a filter (W1) and assembling it into a cassette and taking a sample. In the laboratory the filter is removed from the cassette, desiccated to remove any collected water or other volatile substances, and weighed again (W2). The filter is then extracted in an organic solvent blend, allowed to dry, and weighed a final time (W3). The total weight collected by the filter is given by (W2-W1), and the weight of (nonvolatile) metalworking fluid collected is given by (W2-W3). The extraction step can take place within a cassette housing if it is relatively inert to the solvent blend used. The extraction of four metalworking fluids (straight oil, soluble oil, synthetic and semisynthetic) within disposable polypropylene cassettes was investigated using the same protocol used to evaluate the original method. For all fluids the extraction efficiency was greater than 95% with a precision better than 5%. The mean blank contribution to the extraction step was 16 micrograms. Blanks were also evaluated after storage, and after transport and storage. A small additional blank contribution could be removed by desiccation. The limits of detection and quantitation of the extraction step were calculated to be 28 and 94 micrograms, respectively.
Ray, Mary C.; Kulongoski, Justin T.; Belitz, Kenneth
2009-01-01
Ground-water quality in the approximately 620-square-mile San Francisco Bay study unit (SFBAY) was investigated from April through June 2007 as part of the Priority Basin project of the Ground-Water Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin project was developed in response to the Groundwater Quality Monitoring Act of 2001, and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The study was designed to provide a spatially unbiased assessment of raw ground-water quality, as well as a statistically consistent basis for comparing water quality throughout California. Samples in SFBAY were collected from 79 wells in San Francisco, San Mateo, Santa Clara, Alameda, and Contra Costa Counties. Forty-three of the wells sampled were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study unit (grid wells). Thirty-six wells were sampled to aid in evaluation of specific water-quality issues (understanding wells). The ground-water samples were analyzed for a large number of synthetic organic constituents (volatile organic compounds [VOC], pesticides and pesticide degradates, pharmaceutical compounds, and potential wastewater-indicator compounds), constituents of special interest (perchlorate and N-nitrosodimethylamine [NDMA]), naturally occurring inorganic constituents (nutrients, major and minor ions, trace elements, chloride and bromide isotopes, and uranium and strontium isotopes), radioactive constituents, and microbial indicators. Naturally occurring isotopes (tritium, carbon-14 isotopes, and stable isotopes of hydrogen, oxygen, nitrogen, boron, and carbon), and dissolved noble gases (noble gases were analyzed in collaboration with Lawrence Livermore National Laboratory) also were measured to help identify the source and age of the sampled ground water. Quality-control samples (blank samples, replicate samples, matrix spike samples) were collected for approximately one-third of the wells, and the results for these samples were used to evaluate the quality of the data for the ground-water samples. Assessment of the quality-control information from the field blanks resulted in applying 'V' codes to approximately 0.1 percent of the data collected for ground-water samples (meaning a constituent was detected in blanks as well as the corresponding environmental data). See the Appendix section 'Quality-Control-Sample Results'. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, water typically is treated, disinfected, and (or) blended with other waters to maintain acceptable water quality. Regulatory thresholds apply to treated water that is delivered to the consumer, not to raw ground water. However, to provide some context for the results, concentrations of constituents measured in the raw ground water were compared with regulatory and non-regulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and California Department of Public Health (CDPH) and thresholds established for aesthetic concerns (secondary maximum contaminant levels, SMCL-CA) by CDPH. VOCs were detected in about one-half of the grid wells, while pesticides were detected in about one-fifth of the grid wells. Concentrations of all VOCs and pesticides detected in samples from all SFBAY wells were below health-based thresholds. No pharmaceutical compounds were detected in any SFBAY well. One potential wastewater-indicator compound, caffeine, was detected in one grid well in SFBAY. Concentrations of most trace elements and nutrients detected in samples from all SFBAY wells were below health-based thresholds. Exceptions include nitrate, detected above the USEPA maximum contaminant level (MCL-US) in 3samples; arsenic, above the USEPA maximum contaminant level (MCL-US) in 3 samples; c
NASA Astrophysics Data System (ADS)
Nikolaev, I. V.; Klein, O. I.; Kulikova, N. A.; Stepanova, E. V.; Koroleva, O. V.
2009-04-01
Introduction Recently, many farmers have converted to low-disturbance tillage land cultivation as disk or plow fields can result in water and wind erosion of soil. So, crop residue and plant crowns and roots are left to hold the soil. However, low-disturbance tillage can be a challenge to manage since the key to crop production still requires good seed-to-soil contact. Therefore, decomposition of stubble in agricultural soils in situ is an issue of the day of modern agriculture. The aim of the present study was to compare different organic and inorganic fertilizer supplements on decomposition of cereal stubble remains in chernozem soil. Materials and methods Field trials were conducted in Krasnodar region, Russia. To promote stubble decomposition, a biopreparation that was cultural liquid obtained during cultivation of white-rot fungi Coriolus hirsutus 075 (Wulf Ex. Fr.) Quel. was used at the dosage of 150 ml/ha. The other tested supplements included ammonium nitrate (34 kg/ha), commercially available humate LignohumateTM (0.2 kg/ha) and combination of Lignohumate and biopreparation. Test plots were treated once after wheat harvesting. Non-treated ploughed plot was used as a blank. Soil samples were collected within 2 and 14 weeks after soil treatment. To control soil potential for stubble remains decomposition enzymatic activity is soil was determined. To perform soil analysis, stubble remains were carefully separated from soils followed by soil extraction with 0.14 M phosphate buffer pH 7.1 and analysis of the extracts for laccase and peroxidase activities [1,2]. Estimation of stubble decomposition in soil was performed by cellulose contents determination [3]. Results and discussion The obtained results demonstrated after 14 weeks of treatment increase of soil enzymatic activity due to soil supplementation was observed. Introduction of ammonium nitrate resulted in 108% of peroxidise activity as compared to blank. That value for Lignohumate variant was estimated as 106%. The most pronounced promoting effect on soil enzymatic activity was observed for biopreparation and its combination with Lignohumate where peroxidise activity was as much as 180% and 425% respectively. Moreover, for the above supplements enhancement of laccase activity was also observed, while ammonium nitrate or Lignohumate did not affect that parameter. Treatment of soil with biopreparation led to increase of laccase activity to 265% of blank value, and combined introduction of biopreparation with Lignohumate to 390%. That finding was evident for high potential of soil treated with biopreparation or its combination with Lignohumate to decompose cereal stubble remains. The latter was confirmed by direct measurements of cellulose contents in soil. The most dramatic decrease in plant residue cellulose content was registered for soils treated with biopreparation and Lignohumate where it was 32.4 and 44.3% of blank value respectively. Conclusions Effects of mineral and organic supplements on decomposition of cereal stubble remains in chernozem soil were determined. Among supplements studied, the most efficient treatment was combined application of biopreparation with Lignohumate. Acknowledgements Authors express their deepest appreciation to O.A. Gladkov and SPA RET for the field trials. References 1. Childs R.E., Bardsley W.G. Biochem. J. 1975, 145, 93-103 2. Solomon E.J., Sundaram U.M., Machonkin T.E. Chem. Rev. 1996, 96, 2563-2605 3. Dubois M., Gilles K.A., Hamilton J.K., Rebers P.A., Smith F. Analyt. Chem. 1956, 28, 350-356.
Method for mask repair using defect compensation
Sweeney, Donald W.; Ray-Chaudhuri, Avijit K.
2001-01-01
A method for repair of amplitude and/or phase defects in lithographic masks. The method involves modifying or altering a portion of the absorber pattern on the surface of the mask blank proximate to the mask defect to compensate for the local disturbance (amplitude or phase) of the optical field due to the defect.
Metal flow of a tailor-welded blank in deep drawing process
NASA Astrophysics Data System (ADS)
Yan, Qi; Guo, Ruiquan
2005-01-01
Tailor welded blanks were used in the automotive industry to consolidate parts, reduce weight, and increase safety. In recent years, this technology was developing rapidly in China. In Chinese car models, tailor welded blanks had been applied in a lot of automobile parts such as rail, door inner, bumper, floor panel, etc. Concerns on the properties of tailor welded blanks had become more and more important for automobile industry. A lot of research had shown that the strength of the welded seam was higher than that of the base metal, such that the weld failure in the aspect of strength was not a critical issue. However, formability of tailor welded blanks in the stamping process was complex. Among them, the metal flow of tailor welded blanks in the stamping process must be investigated thoroughly in order to reduce the scrap rate during the stamping process in automobile factories. In this paper, the behavior of metal flow for tailor welded blanks made by the laser welding process with two types of different thickness combinations were studied in the deep drawing process. Simulations and experiment verification of the movement of weld line for tailor welded blanks were discussed in detail. Results showed that the control on the movement of welded seam during stamping process by taking some measures in the aspect of blank holder was effective.
System 6: A pricing strategy for long blanks
Hugh W. Reynolds; Bruce G. Hansen; Bruce G. Hansen
1986-01-01
In System 6, small-diameter, low-grade hardwood timber is used to make blanks in standard sizes. Blanks are made in one thickness and one quality class but in all the standard lengths during each production run. The quantity of blanks per length can be varied, while keeping total yield high, by using proper production control techniques. However, when the percentage of...
Surface modifications of AISI 420 stainless steel by low energy Yttrium ions
NASA Astrophysics Data System (ADS)
Nassisi, Vincenzo; Delle Side, Domenico; Turco, Vito; Martina, Luigi
2018-01-01
In this work, we study surface modifications of AISI 420 stainless steel specimens in order to improve their surface properties. Oxidation resistance and surface micro-hardness were analyzed. Using an ion beam delivered by a Laser Ion Source (LIS) coupled to an electrostatic accelerator, we performed implantation of low energy yttrium ions on the samples. The ions experienced an acceleration passing through a gap whose ends had a potential difference of 60 kV. The gap was placed immediately before the samples surface. The LIS produced high ions fluxes per laser pulse, up to 3x1011 ions/cm2, resulting in a total implanted flux of 7x1015 ions/cm2. The samples were characterized before and after ion implantation using two analytical techniques. They were also thermally treated to investigate the oxide scale. The crystal phases were identified by an X-ray diffractometer, while the micro-hardness was assayed using the scratch test and a profilometer. The first analysis was applied to blank, implanted and thermally treated sample surface, while the latter was applied only to blank and implanted sample surfaces. We found a slight increase in the hardness values and an increase to oxygen resistance. The implantation technique we used has the advantages, with respect to conventional methods, to modify the samples at low temperature avoiding stray diffusion of ions inside the substrate bulk.
NASA Astrophysics Data System (ADS)
Pinnegar, J. K.; Goñi, N.; Trenkel, V. M.; Arrizabalaga, H.; Melle, W.; Keating, J.; Óskarsson, G.
2014-04-01
There is increasing demand for information on predator-prey interactions in the ocean as a result of legislative commitments aimed at achieving sustainable exploitation. However, comprehensive datasets are lacking for many fish species and this has hampered development of multispecies fisheries models and the formulation of effective food-web indicators. This work describes a new compilation of stomach content data for five pelagic fish species (herring, blue whiting, mackerel, albacore and bluefin tuna) sampled across the northeast Atlantic and submitted to the PANGAEA open-access data portal (www.pangaea.de). We provide detailed descriptions of sample origin and of the corresponding database structures. We describe the main results in terms of diet composition and predator-prey relationships. The feeding preferences of small pelagic fish (herring, blue whiting, mackerel) were sampled over a very broad geographic area within the North Atlantic basin, from Greenland in the west, to the Lofoten Islands in the east and from the Bay of Biscay northwards to the Arctic. This analysis revealed significant differences in the prey items selected in different parts of the region at different times of year. Tunas (albacore and bluefin) were sampled in the Bay of Biscay and Celtic Sea. Dominant prey items for these species varied by location, year and season. This data compilation exercise represents one of the largest and most wide-ranging ever attempted for pelagic fish in the north Atlantic. The earliest data included in the database were collected in 1864, whereas the most recent were collected in 2012.Datasets are available at doi:10.1594/PANGAEA.820041 and doi:10.1594/PANGAEA.826992.
NASA Astrophysics Data System (ADS)
Atek, Hakim; Richard, Johan; Kneib, Jean-Paul; Jauzac, Mathilde; Schaerer, Daniel; Clement, Benjamin; Limousin, Marceau; Jullo, Eric; Natarajan, Priyamvada; Egami, Eiichi; Ebeling, Harald
2015-02-01
Exploiting the power of gravitational lensing, the Hubble Frontier Fields (HFF) program aims at observing six massive galaxy clusters to explore the distant universe far beyond the limits of blank field surveys. Using the complete Hubble Space Telescope observations of the first HFF cluster A2744, we report the detection of 50 galaxy candidates at z ~ 7 and eight candidates at z ~ 8 in a total survey area of 0.96 arcmin2 in the source plane. Three of these galaxies are multiply imaged by the lensing cluster. Using an updated model of the mass distribution in the cluster we were able to calculate the magnification factor and the effective survey volume for each galaxy in order to compute the ultraviolet galaxy luminosity function (LF) at both redshifts 7 and 8. Our new measurements reliably extend the z ~ 7 UV LF down to an absolute magnitude of M UV ~ -15.5. We find a characteristic magnitude of M\\star UV = -20.90+0.90-0.73 mag and a faint-end slope α =-2.01+0.20-0.28, close to previous determinations in blank fields. We show here for the first time that this slope remains steep down to very faint luminosities of 0.01 L sstarf. Although prone to large uncertainties, our results at z ~ 8 also seem to confirm a steep faint-end slope below 0.1 L sstarf. The HFF program is therefore providing an extremely efficient way to study the faintest galaxy populations at z > 7 that would otherwise be inaccessible with current instrumentation. The full sample of six galaxy clusters will provide even better constraints on the buildup of galaxies at early epochs and their contribution to cosmic reionization. Based on observations made with the NASA/ESA Hubble Space Telescope, which is operated by the Association of Universities for Research in Astronomy, Inc., under NASA contract NAS 5-26555. These observations are associated with programs 13495, 11386, 13389, and 11689. STScI is operated by the Association of Universities for Research in Astronomy, Inc. under NASA contract NAS 5-26555. The Hubble Frontier Fields data were obtained from the Mikulski Archive for Space Telescopes (MAST).
Modified blank ammunition injuries.
Ogunc, Gokhan I; Ozer, M Tahir; Coskun, Kagan; Uzar, Ali Ihsan
2009-12-15
Blank firing weapons are designed only for discharging blank ammunition cartridges. Because they are cost-effective, are easily accessible and can be modified to live firearms plus their unclear legal situation in Turkish Law makes them very popular in Turkey. 2004 through 2008, a total of 1115 modified blank weapons were seized in Turkey. Blank firing weapons are easily modified by owners, making them suitable for discharging live firearm ammunition or modified blank ammunitions. Two common methods are used for modification of blank weapons. After the modification, these weapons can discharge the live ammunition. However, due to compositional durability problems with these types of weapons; the main trend is to use the modified blank ammunitions rather than live firearm ammunition fired from modified blank firing weapons. In this study, two types of modified blank weapons and two types of modified blank cartridges were tested on three different target models. Each of the models' shooting side was coated with 1.3+/-2 mm thickness chrome tanned cowhide as a skin simulant. The first model was only coated with skin simulant. The second model was coated with skin simulant and 100% cotton police shirt. The third model was coated with skin simulant and jean denim. After the literature evaluation four high risky anatomic locations (the neck area; the eyes; the thorax area and inguinal area) were pointed out for the steel and lead projectiles are discharged from the modified blank weapons especially in close range (0-50 cm). The target models were designed for these anatomic locations. For the target models six Transparent Ballistic Candle blocks (TCB) were prepared and divided into two test groups. The first group tests were performed with lead projectiles and second group with steel projectile. The shortest penetration depth (lead projectile: 4.358 cm; steel projectile 8.032 cm) was recorded in the skin simulant and jean denim coated block for both groups. In both groups, the longest penetration depth (lead projectile: 6.434 cm; steel projectile 8.608 cm) was recorded in the only skin simulant coated block. And the penetration depth of skin simulant and 100% cotton police shirt coated model was 5.870 cm for lead projectile; 8.440 cm for steel projectile. According to penetration results, national and international legislations and production standards should be re-evaluated in order to prevent the modification of blank weapons and ammunitions. There are three methods for preventing modification of blank weapons: completely closed barrel structure; intersected restrain pieces application; eccentric barrel structure.
NASA Astrophysics Data System (ADS)
Kojima, Yosuke; Shirasaki, Masanori; Chiba, Kazuaki; Tanaka, Tsuyoshi; Inazuki, Yukio; Yoshikawa, Hiroki; Okazaki, Satoshi; Iwase, Kazuya; Ishikawa, Kiichi; Ozawa, Ken
2007-05-01
For 45 nm node and beyond, the alternating phase-shift mask (alt. PSM), one of the most expected resolution enhancement technologies (RET) because of its high image contrast and small mask error enhancement factor (MEEF), and the binary mask (BIM) attract attention. Reducing CD and registration errors and defect are their critical issues. As the solution, the new blank for alt. PSM and BIM is developed. The top film of new blank is thin Cr, and the antireflection film and shielding film composed of MoSi are deposited under the Cr film. The mask CD performance is evaluated for through pitch, CD linearity, CD uniformity, global loading, resolution and pattern fidelity, and the blank performance is evaluated for optical density, reflectivity, sheet resistance, flatness and defect level. It is found that the performance of new blank is equal to or better than that of conventional blank in all items. The mask CD performance shows significant improvement. The lithography performance of new blank is confirmed by wafer printing and AIMS measurement. The full dry type alt. PSM has been used as test plate, and the test results show that new blank can almost meet the specifications of pi-0 CD difference, CD uniformity and process margin for 45 nm node. Additionally, the new blank shows the better pattern fidelity than that of conventional blank on wafer. AIMS results are almost same as wafer results except for the narrowest pattern. Considering the result above, this new blank can reduce the mask error factors of alt. PSM and BIM for 45 nm node and beyond.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yan, Pei-Yang; Zhang, Guojing; Gullickson, Eric M.
Extreme ultraviolet lithography (EUVL) mask multi-layer (ML) blank surface roughness specification historically comes from blank defect inspection tool requirement. Later, new concerns on ML surface roughness induced wafer pattern line width roughness (LWR) arise. In this paper, we have studied wafer level pattern LWR as a function of EUVL mask surface roughness via High-NA Actinic Reticle Review Tool. We found that the blank surface roughness induced LWR at current blank roughness level is in the order of 0.5nm 3σ for NA=0.42 at the best focus. At defocus of ±40nm, the corresponding LWR will be 0.2nm higher. Further reducing EUVL maskmore » blank surface roughness will increase the blank cost with limited benefit in improving the pattern LWR, provided that the intrinsic resist LWR is in the order of 1nm and above.« less
Ion beam deposition system for depositing low defect density extreme ultraviolet mask blanks
NASA Astrophysics Data System (ADS)
Jindal, V.; Kearney, P.; Sohn, J.; Harris-Jones, J.; John, A.; Godwin, M.; Antohe, A.; Teki, R.; Ma, A.; Goodwin, F.; Weaver, A.; Teora, P.
2012-03-01
Extreme ultraviolet lithography (EUVL) is the leading next-generation lithography (NGL) technology to succeed optical lithography at the 22 nm node and beyond. EUVL requires a low defect density reflective mask blank, which is considered to be one of the top two critical technology gaps for commercialization of the technology. At the SEMATECH Mask Blank Development Center (MBDC), research on defect reduction in EUV mask blanks is being pursued using the Veeco Nexus deposition tool. The defect performance of this tool is one of the factors limiting the availability of defect-free EUVL mask blanks. SEMATECH identified the key components in the ion beam deposition system that is currently impeding the reduction of defect density and the yield of EUV mask blanks. SEMATECH's current research is focused on in-house tool components to reduce their contributions to mask blank defects. SEMATECH is also working closely with the supplier to incorporate this learning into a next-generation deposition tool. This paper will describe requirements for the next-generation tool that are essential to realize low defect density EUV mask blanks. The goal of our work is to enable model-based predictions of defect performance and defect improvement for targeted process improvement and component learning to feed into the new deposition tool design. This paper will also highlight the defect reduction resulting from process improvements and the restrictions inherent in the current tool geometry and components that are an impediment to meeting HVM quality EUV mask blanks will be outlined.
Evaluation of the Ott Hydromet Qliner for measuring discharge in laboratory and field conditions
McVay, Jason C.
2015-01-01
The U.S. Geological Survey, in collaboration with the University of Iowa IIHR – Hydroscience and Engineering, evaluated the use of the Ott Hydromet Qliner using laboratory flume tests along with field validation tests. Analysis of the flume testing indicates the velocities measured by the Qliner at a 40-second exposure time results in higher dispersion of velocities from the mean velocity of data collected with a 5-minute exposure time. The percent data spread from the mean of a 100-minute mean of Qliner velocities for a 40-second exposure time averaged 16.6 percent for the entire vertical, and a 5-minute mean produced a 6.2 percent data spread from the 100-minute mean. This 16.6 percent variation in measured velocity would result in a 3.32 percent variation in computed discharge assuming 25 verticals while averaging 4 bins in each vertical. The flume testing also provided results that indicate the blanking distance of 0.20 meters is acceptable when using beams 1 and 2, however beam 3 is negatively biased near the transducer and the 0.20-meter blanking distance is not sufficient. Field testing included comparing the measured discharge by the Qliner to the discharge measured by a Price AA mechanical current meter and a Teledyne RDI Rio Grande 1200 kilohertz acoustic Doppler current profiler. The field tests indicated a difference between the discharges measured with the Qliner and the field reference discharge between -14.0 and 8.0 percent; however the average percent difference for all 22 field comparisons was 0.22, which was not statistically significant.
Method of making dished ion thruster grids
NASA Technical Reports Server (NTRS)
Banks, B. A. (Inventor)
1975-01-01
A pair of flat grid blanks are clamped together at their edges with an impervious metal sheet on top. All of the blanks and sheets are dished simultaneously by forcing fluid to inflate an elastic sheet which contacts the bottom grid blank. A second impervious metal sheet is inserted between the two grid blanks if the grids have high percentage open areas. The dished grids are stress relieved simultaneously.
Long-term vegetation monitoring in Great Britain - the Countryside Survey 1978-2007 and beyond
NASA Astrophysics Data System (ADS)
Wood, Claire M.; Smart, Simon M.; Bunce, Robert G. H.; Norton, Lisa R.; Maskell, Lindsay C.; Howard, David C.; Scott, W. Andrew; Henrys, Peter A.
2017-07-01
The Countryside Survey (CS) of Great Britain provides a globally unique series of datasets, consisting of an extensive set of repeated ecological measurements at a national scale, covering a time span of 29 years. CS was first undertaken in 1978 to monitor ecological and land use change in Britain using standardised procedures for recording ecological data from representative 1 km squares throughout the country. The same sites, with some additional squares, were used for subsequent surveys of vegetation undertaken in 1990, 1998 and 2007, with the intention of future surveys. Other data records include soils, freshwater habitats and invertebrates, and land cover and landscape feature diversity and extents. These data have been recorded in the same locations on analogous dates. However, the present paper describes only the details of the vegetation surveys. The survey design is a series of gridded, stratified, randomly selected 1 km squares taken as representative of classes derived from a statistical environmental classification of Britain. In the 1978 survey, 256 one-kilometre sample squares were recorded, increasing to 506 in 1990, 569 in 1998 and 591 in 2007. Initially each square contained up to 11 dispersed vegetation plots but additional plots were later placed in different features so that eventually up to 36 additional sampling plots were recorded, all of which can be relocated where possible (unless the plot has been lost, for example as a consequence of building work), providing a total of 16 992 plots by 2007. Plots are estimated to have a precise relocation accuracy of 85 %. A range of plots located in different land cover types and landscape features (for example, field boundaries) are included. Although a range of analyses have already been carried out, with changes in the vegetation being related to a range of drivers at local and national scales, there is major potential for further analyses, for example in relation to climate change. Although the precise locations of the plots are restricted, largely for reasons of landowner confidentiality, sample sites are intended to be representative of larger areas, and many potential opportunities for further analyses remain. Data from each of the survey years (1978, 1990, 1998, 2007) are available via the following DOIs: Countryside Survey 1978 vegetation plot data (https://doi.org/10.5285/67bbfabb-d981-4ced-b7e7-225205de9c96), Countryside Survey 1990 vegetation plot data (https://doi.org/10.5285/26e79792-5ffc-4116-9ac7-72193dd7f191), Countryside Survey 1998 vegetation plot data (https://doi.org/10.5285/07896bb2-7078-468c-b56d-fb8b41d47065), Countryside Survey 2007 vegetation plot data (https://doi.org/10.5285/57f97915-8ff1-473b-8c77-2564cbd747bc).
NASA Astrophysics Data System (ADS)
Park, Keecheol; Park, Jongyoun; Nam, Jaebok
2011-08-01
Due to the application of thinner sheet steels, the stamped panels in the forming process, generally, are severely distorted. The wavy shape of embossed panel finally converted to residual stress embedded in the panel at final forming (edge L-bending) and it is known as the cause of twisting and oil canning of spring backed panel. Another important source of stamped shape deviation is the curvature of blank. The effects of blank curvature on the shape defects (panel curvature and twisting) after stamping were investigated from defective panel analysis, model experiment and stamping simulation. And the effect of tool conditions (BHF and bead height change) on spring backed shape of real TV bottom chassis were studied. The initial curvature of blank was remained in the flat area of stamped panels as width directional curvature. It converted from length direction curvature of blank. The curvature of initial blank reduced the wavy shape after local emboss forming, but twisting after edge L-bending was increased at large blank curvature cases. The effects of emboss forming conditions, the forming heights and blank holding force were studied and it was found that the wavy shape of stamped sheet was rapidly changed although the forming conditions altered very small amount.
NASA Astrophysics Data System (ADS)
Slange, T. K.; Warnet, L. L.; Grouve, W. J. B.; Akkerman, R.
2018-05-01
Stamp forming is a rapid manufacturing technology used to shape flat blanks of thermoplastic composite material into three-dimensional components. The combination with rapid AFP as blank manufacturing technology can further extend the applicability of stamp forming by allowing rapid lay-up of tailored blanks and offering partial preconsolidation. In an experimental study it is demonstrated that high quality laminates with good flexural strength can be obtained by following this process route. The consolidation of ply-drop regions is demonstrated by flat laminates with a thickness step. The influence of fiber orientations, blank-tooling misalignments and AFP tolerances is investigated.
Zhang, Bin; Deng, Shang-gui; Gao, Meng; Chen, Jing
2015-04-01
The effect of slurry ice on the quality of Skipjack tuna (Katsuwonus pelamis) during chilling storage was investigated and compared to flake ice. Slurry ice-treated samples showed significantly higher springiness and chewiness variables than the blank and flake ice-treated samples (P < 0.05). The growth of microorganisms in tuna muscle treated with slurry ice was also down significantly (P < 0.05), and the total aerobic counts didn't reach higher scores than 5.0 log CFU/g during the whole chilling storage. Additionally, the myofibrillar protein, Ca(2+)-ATPase activity, and total sulfydryl (SH) content in muscle treated with slurry ice were all significantly higher than the blank and flake-iced samples (P < 0.05). This was probably due to the faster cooling, subzero final-temperature, and larger heat exchange derived from slurry ice. Standard error of mean and sodium dodecyl sulfate-polyacrylamide gel electrophoresis results also confirmed that slurry ice treatment could effectively retard the degradation of myofibrillar proteins and showed a positive effect on the stability of tissue structures. © 2015 Institute of Food Technologists®
NASA Astrophysics Data System (ADS)
Xue, Yuejun; Ge, Tiantian; Wang, Xuchen
2015-12-01
Radiocarbon (14C) measurement of dissolved organic carbon (DOC) is a very powerful tool to study the sources, transformation and cycling of carbon in the ocean. The technique, however, remains great challenges for complete and successful oxidation of sufficient DOC with low blanks for high precision carbon isotopic ratio analysis, largely due to the overwhelming proportion of salts and low DOC concentrations in the ocean. In this paper, we report an effective UV-Oxidation method for oxidizing DOC in natural waters for radiocarbon analysis by accelerator mass spectrometry (AMS). The UV-oxidation system and method show 95%±4% oxidation efficiency and high reproducibility for DOC in both river and seawater samples. The blanks associated with the method was also low (about 3 µg C) that is critical for 14C analysis. As a great advantage of the method, multiple water samples can be oxidized at the same time so it reduces the sample processing time substantially compared with other UV-oxidation method currently being used in other laboratories. We have used the system and method for 14C studies of DOC in rivers, estuaries, and oceanic environments and have received promise results.
Cheating the Business Template: Filling in the Blanks
ERIC Educational Resources Information Center
Mechenbier, Mahli Xuan
2011-01-01
Business professionals often use standard templates when composing documents, and teachers of business writing direct students to textbook examples to use as sample formats. Good instructors do want to provide their students with informative examples of what is expected, especially in an online course environment where students cannot raise their…
21 CFR 177.1010 - Acrylic and modified acrylic plastics, semirigid and rigid.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 0.3 milligram per square inch of surface tested. (2) Potassium permanganate oxidizable distilled... permanganate test shall be determined by preparing duplicate permanganate test blanks according to paragraph (c... permanganate test determinations shall be run on samples of distilled water and 8 and 50 percent alcohol...
Flight dynamics system software development environment (FDS/SDE) tutorial
NASA Technical Reports Server (NTRS)
Buell, John; Myers, Philip
1986-01-01
A sample development scenario using the Flight Dynamics System Software Development Environment (FDS/SDE) is presented. The SDE uses a menu-driven, fill-in-the-blanks format that provides online help at all steps, thus eliminating lengthy training and allowing immediate use of this new software development tool.
Hypothesis Sampling Systems among Preoperational and Concrete Operational Kindergarten Children
ERIC Educational Resources Information Center
Gholson, Barry; And Others
1976-01-01
Preoperational and concrete operational kindergarten children received stimulus differentiation training, either with or without feedback, and then a series of discrimination learning problems in which a blank trial probe was used to detect a child's hypothesis after each feedback trial. Piagetian stage theory requires elaboration to account…
1991-09-01
SALES AND MILITARY ASSISTANCE PROGRAM GRANT AID REQUISITIONAJ DLMSTYPE REQUISITION DATA ELEMENT (MANUAL) (MECHANICAL) REFERENCE FIELD LEGEND BLOCK NO...as shown in DI AFX or DI AFZ. RASOI All Other Fields 67-80 Leave blank. T Transaction Set 519 C9-4 DoD 4000.25-1-M-S-3 APPENDIX C10 FOREIGN MILITARY ...existing DLSS formats, codes, and procedures have been utilized in DoD logistics for nearly 30 years and they are deeply embedded within Military Service
2008-02-01
1996. [15] Gambrill, C.S. DeAngelis M.L., Lu S-T. Error analysis of a thermometric microwave-dosimetry procedure. In: Blank M, editor. Electricity...Transactions on Biomedical Engineering, Vol. BME-31, No. 7, July 1984, 533-536. [18] Lu S-T, DeAngelis ML, Gambrill CS. Ocular microwave thermometric
Avoidance of Cigarette Pack Health Warnings among Regular Cigarette Smokers
Maynard, Olivia M.; Attwood, Angela; O’Brien, Laura; Brooks, Sabrina; Hedge, Craig; Leonards, Ute; Munafò, Marcus R.
2016-01-01
Background Previous research with adults and adolescents indicates that plain cigarette packs increase visual attention to health warnings among non-smokers and non-regular smokers, but not among regular smokers. This may be because regular smokers: 1) are familiar with the health warnings, 2) preferentially attend to branding, or 3) actively avoid health warnings. We sought to distinguish between these explanations using eye-tracking technology. Method A convenience sample of 30 adult dependant smokers were recruited to participate in an eye-tracking study. Participants viewed branded, plain and blank packs of cigarettes with familiar and unfamiliar health warnings. The number of fixations to health warnings and branding on the different pack types were recorded. Results Analysis of variance indicated that regular smokers were biased towards fixating the branding location rather than the health warning location on all three pack types (p < 0.002). This bias was smaller, but still evident, for blank packs, where smokers preferentially attended the blank region over the health warnings. Time-course analysis showed that for branded and plain packs, attention was preferentially directed to the branding location for the entire 10 seconds of the stimulus presentation, while for blank packs this occurred for the last 8 seconds of the stimulus presentation. Familiarity with health warnings had no effect on eye gaze location. Conclusion Smokers actively avoid cigarette pack health warnings, and this remains the case even in the absence of salient branding information. Smokers may have learned to divert their attention away from cigarette pack health warnings. These findings have policy implications for the design of health warning on cigarette packs. PMID:24485554
Testing glueline continuity in standard-size hardwood blanks by mechanical methods
David W. Patterson; Nathan D. Hesterman; Charles Gatchell
1991-01-01
Glueline continuity is very critical in standard-size hardwood blanks because the blanks are cut up into small furniture parts, and a small gap in the glueline of a blank may extend across the whole partâor a gap may appear as a crack in the final product. Strength is not a critical factor. The objective of this study was to determine if a gap in a glueline can be...
Dillon, David B.; Davis, Tracy A.; Landon, Matthew K.; Land, Michael T.; Wright, Michael T.; Kulongoski, Justin T.
2016-12-09
Exploratory sampling of groundwater in coastal Los Angeles County and Kern and Kings Counties of the southern San Joaquin Valley was done by the U.S. Geological Survey from September 2014 through January 2015 as part of the California State Water Resources Control Board’s Water Quality in Areas of Oil and Gas Production Regional Groundwater Monitoring Program. The Regional Groundwater Monitoring Program was established in response to the California Senate Bill 4 of 2013 mandating that the California State Water Resources Control Board design and implement a groundwater-monitoring program to assess potential effects of well-stimulation treatments on groundwater resources in California. The U.S. Geological Survey is in cooperation with the California State Water Resources Control Board to collaboratively implement the Regional Groundwater Monitoring Program through the California Oil, Gas, and Groundwater Project. Many researchers have documented the utility of different suites of chemical tracers for evaluating the effects of oil and gas development on groundwater quality. The purpose of this exploratory sampling effort was to determine whether tracers reported in the literature could be used effectively in California. This reconnaissance effort was not designed to assess the effects of oil and gas on groundwater quality in the sampled areas. A suite of water-quality indicators and geochemical tracers were sampled at groundwater sites in selected areas that have extensive oil and gas development. Groundwater samples were collected from a total of 51 wells, including 37 monitoring wells at 17 multiple-well monitoring sites in coastal Los Angeles County and 5 monitoring wells and 9 water-production wells in southern San Joaquin Valley, primarily in Kern and Kings Counties. Groundwater samples were analyzed for field waterquality indicators; organic constituents, including volatile and semi-volatile organic compounds and dissolved organic carbon indicators; naturally present inorganic constituents, including trace elements, nutrients, major and minor ions, and iron species; naturally present stable and radioactive isotopes; dissolved noble gases; dissolved standard and hydrocarbon gases, δ13C of methane, ethane, and δ2 H of methane. In total, 249 constituents and water-quality indicators were measured. Four types of quality-control samples (blanks, replicates, matrix spikes, and surrogates spiked in environmental and blank samples) were collected at approximately 10 percent of the wells. The quality-control data were used to determine whether the groundwater-sample data were of sufficient quality for the measured analytes to be used as potential indicators of oil and gas effects. The data from the 51 groundwater samples and from the quality-control samples are presented in this report.
A 1.1mm AzTEC Survey Tracing Accelerated Galaxy Formation Towards a Protocluster at z 3.8
NASA Astrophysics Data System (ADS)
Hughes, David H.; Montana, A.; Aretxaga, I.; Plionis, M.; Porras, A.; Wagg, J.; Gaztanaga, E.; Huang, J.; Fazio, G.; Wilson, G.; Yun, M.; Lowenthal, J.; Perera, T.; Austermann, J.; Scott, K.; Dunlop, J.; Ivison, R.; Stevens, J.; Smail, I.; Appleton, P.
2006-12-01
Aztec has recently conducted a sensitive, wide-area (300 sq. Armin's) continuum survey at 1.1mm using the 15-m James Clerk Maxwell Telescope towards 4C41.17, a powerful high-redshift (z 3.8) radio galaxy. These Aztec data, which cover an area >40 times larger than our previous SCUBA survey, reveal a significant over-density of luminous, massive dust-enshrouded galaxies, compared to the results from lower-redshift blank-field sub-mm surveys. One natural interpretation of these new AzTEC data is that the over-density is tracing a large (5 x 5 Mpc) "proto-cluster" structure at z 3.8 associated with the environment of 4C41.17, within which the formation of ultra-luminous starburst galaxies (with rest-frame FIR luminosities >5 x 1012 Lsun or SFRs > 500 Msun/yr) is taking place at an accelerated rate. Proving the physical association of these massive optically-faint starbursts with the environment of this high-z AGN, and not with the blank-field sub-mm population, for which 50% of the population lies at 1.9 < z < 2.9, remains an outstanding problem. In this presentation we will describe the AzTEC survey, the empirical evidence for this protocluster structure in the early universe, and the planned multi-wavelength follow-up observations of the brightest AzTEC sources towards 4C41.17 that may demonstrate that we are witnessing accelerated galaxy formation, via an increased rate of merging gas-rich galaxies within a rapidly-developing gravitational potential. AzTEC is one of the suite of instruments destined for the 50-m Large Millimeter Telescope (LMT). We will conclude this presentation with a summary of future LMT observations that will trace the evolution of obscured starformation in the dynamic environments towards a significant sample of intermediate and high-z powerful AGN with greater sensitivity and spatial resolution.
Lee, Kathy E.; Langer, Susan K.; Menheer, Michael A.; Foreman, William T.; Furlong, Edward T.; Smith, Steven G.
2012-01-01
The U.S. Geological Survey (USGS) cooperated with the U.S. Environmental Protection Agency and the U.S. Fish and Wildlife Service on a study to identify the occurrence of chemicals of emerging concern (CECs) in water and bottom-sediment samples collected during 2010–11 at sites in seven areas of concern (AOCs) throughout the Great Lakes. Study sites include tributaries to the Great Lakes in AOCs located near Duluth, Minn.; Green Bay, Wis.; Rochester, N.Y.; Detroit, Mich.; Toledo, Ohio; Milwaukee, Wis.; and Ashtabula, Ohio. This report documents the collection methods, analyses methods, quality-assurance data and analyses, and provides the data for this study. Water and bottom-sediment samples were analyzed at the USGS National Water Quality Laboratory in Denver, Colo., for a broad suite of CECs. During this study, 135 environmental and 23 field duplicate samples of surface water and wastewater effluent, 10 field blank water samples, and 11 field spike water samples were collected and analyzed. Sixty-one of the 69 wastewater indicator chemicals (laboratory method 4433) analyzed were detected at concentrations ranging from 0.002 to 11.2 micrograms per liter. Twenty-eight of the 48 pharmaceuticals (research method 8244) analyzed were detected at concentrations ranging from 0.0029 to 22.0 micrograms per liter. Ten of the 20 steroid hormones and sterols analyzed (research method 4434) were detected at concentrations ranging from 0.16 to 10,000 nanograms per liter. During this study, 75 environmental, 13 field duplicate samples, and 9 field spike samples of bottom sediment were collected and analyzed for a wide variety of CECs. Forty-seven of the 57 wastewater indicator chemicals (laboratory method 5433) analyzed were detected at concentrations ranging from 0.921 to 25,800 nanograms per gram. Seventeen of the 20 steroid hormones and sterols (research method 6434) analyzed were detected at concentrations ranging from 0.006 to 8,921 nanograms per gram. Twelve of the 20 pharmaceuticals (research method 8244) analyzed were detected at concentrations ranging from 2.35 to 453.5 nanograms per gram. Six of the 11 antidepressants (research method 9008) analyzed were detected at concentrations ranging from 2.79 to 91.6 nanograms per gram.
NASA Astrophysics Data System (ADS)
Bour, A. L.; Broek, T.; Walker, B. D.; Mccarthy, M. D.
2014-12-01
The presence of much of the marine dissolved organic nitrogen (DON) pool as uncharacterized, biologically recalcitrant molecules is a central mystery in the marine nitrogen cycle. Radiocarbon (Δ14C) isotopic measurements have been perhaps the most important data constraining the cycling of dissolved organic matter (DOM), but little Δ14C data specific to DON is available. Amino acids (AAs) are the major component of DON that can be isolated on a molecular level. Δ14C measurements for the operational "protein-like" fraction of DOM in the deep ocean indicate that this compound class has radiocarbon ages greater than several ocean mixing cycles, suggesting remarkable preservation of labile AAs exported from the surface. However, it is possible that the previously defined operational "protein-like" fraction may also contain non-AA material. Radiocarbon measurement of purified individual AAs would provide a more direct and reliable proxy for DON Δ14C age and cycling rate. We present here Δ14C blank characterization of an AA purification method based on HPLC, with on-line fraction collection. This method allows the recovery of unmodified AAs, but accurate measurement of small AA samples that can be extracted from DOM requires a system with extremely low Δ 14C blanks. Here we assess the impact of HPLC purification on the Δ14C age of known amino acids standards. Individual AA standards with contrasting (modern vs. dead) and well- characterized Δ14C ages were processed in a range of sample sizes. The eluted peaks were collected and dried, and measurement of their post-chromatography Δ14C content allowed for determination of the Δ14C blank by method of additions. The same protocol was applied to a mixture of six AA standards, to evaluate tailing effects in consecutive AA peaks of contrasting Δ14C age. AA standards were selected to include both Δ14C modern and dead AAs that elute both early and late in the chromatographic solvent program. We discuss implications for future Δ14C analysis of AAs purified from DOM by this method.
The Overdense Environments of WISE-selected, ultra-luminous, high-redshift AGN in the submillimetre
NASA Astrophysics Data System (ADS)
Jones, Suzy F.
2017-11-01
The environments around WISE-selected hot dust obscured galaxies (Hot DOGs) and WISE/radio-selected active galactic nuclei (AGNs) at average redshifts of z = 2.7 and z = 1.7, respectively, were found to have overdensities of companion submillimetre-selected sources. The overdensities were of ˜ 2 - 3 and ˜ 5 - 6 , respectively, compared with blank field submm surveys. The space densities in both samples were found to be overdense compared to normal star-forming galaxies and submillimetre galaxies (SMGs). All of the companion sources have consistent mid-IR colours and mid-IR to submm ratios to SMGs. Monte Carlo simulations show no angular correlation, which could indicate protoclusters on scales larger than the SCUBA-2 1.5 arcmin scale maps. WISE-selected AGNs appear to be good indicators of overdense areas of active galaxies at high redshift.
NASA Astrophysics Data System (ADS)
Tabacaru, LL; Axinte, E.; Musca, G.
2016-11-01
Elastic deformations of the technological system occur during the mechanical treatment of a blank, regardless of the manner in which it is fastened. The elastic deformation of the blank is significant especially when machining shaft-like parts. The purpose of our research is to compare the mathematical model of blank deformation to the experimental model when the blank, which is a part belonging to the shaft class, is fastened between centers.
Shelton, Jennifer L.; Fram, Miranda S.; Belitz, Kenneth
2009-01-01
Groundwater quality in the approximately 860-square-mile Madera-Chowchilla study unit (MADCHOW) was investigated in April and May 2008 as part of the Priority Basin Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin Project was developed in response to the Groundwater Quality Monitoring Act of 2001 and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The study was designed to provide a spatially unbiased assessment of the quality of raw groundwater used for public water supplies within MADCHOW, and to facilitate statistically consistent comparisons of groundwater quality throughout California. Samples were collected from 35 wells in Madera, Merced, and Fresno Counties. Thirty of the wells were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study area (grid wells), and five more were selected to provide additional sampling density to aid in understanding processes affecting groundwater quality (flow-path wells). Detection summaries in the text and tables are given for grid wells only, to avoid over-representation of the water quality in areas adjacent to flow-path wells. Groundwater samples were analyzed for a large number of synthetic organic constituents (volatile organic compounds [VOCs], low-level 1,2-dibromo-3-chloropropane [DBCP] and 1,2-dibromoethane [EDB], pesticides and pesticide degradates, polar pesticides and metabolites, and pharmaceutical compounds), constituents of special interest (N-nitrosodimethylamine [NDMA], perchlorate, and low-level 1,2,3-trichloropropane [1,2,3-TCP]), naturally occurring inorganic constituents (nutrients, major and minor ions, and trace elements), and radioactive constituents (uranium isotopes, and gross alpha and gross beta particle activities). Naturally occurring isotopes and geochemical tracers (stable isotopes of hydrogen, oxygen, and carbon, and activities of tritium and carbon-14), and dissolved noble gases also were measured to help identify the sources and ages of the sampled groundwater. In total, approximately 300 constituents and field water-quality indicators were investigated. Three types of quality-control samples (blanks, replicates, and samples for matrix spikes) each were collected at approximately 11 percent of the wells sampled for each analysis, and the results obtained from these samples were used to evaluate the quality of the data for the groundwater samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that data for the groundwater samples were not compromised by possible contamination during sample collection, handling or analysis. Differences between replicate samples were within acceptable ranges. Matrix spike recoveries were within acceptable ranges for most compounds. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, raw groundwater typically is treated, disinfected, or blended with other waters to maintain water quality. Regulatory thresholds apply to water that is served to the consumer, not to raw groundwater. However, to provide some context for the results, concentrations of constituents measured in the raw groundwater were compared with regulatory and non-regulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and the California Department of Public Health (CDPH), and with aesthetic and technical thresholds established by CDPH. Comparisons between data collected for this study and drinking-water thresholds are for illustrative purposes only, and are not indicative of compliance or non-compliance with regulatory thresholds. The concentrations of most constituents detected in groundwater samples from MADCHOW wells were below drinking-water thresholds. Organic compounds (VOCs and pesticides
Schmitt, Stephen J.; Milby Dawson, Barbara J.; Belitz, Kenneth
2009-01-01
Groundwater quality in the approximately 1,600 square-mile Antelope Valley study unit (ANT) was investigated from January to April 2008 as part of the Priority Basin Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin Project was developed in response to the Groundwater Quality Monitoring Act of 2001, and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The study was designed to provide a spatially unbiased assessment of the quality of raw groundwater used for public water supplies within ANT, and to facilitate statistically consistent comparisons of groundwater quality throughout California. Samples were collected from 57 wells in Kern, Los Angeles, and San Bernardino Counties. Fifty-six of the wells were selected using a spatially distributed, randomized, grid-based method to provide statistical representation of the study area (grid wells), and one additional well was selected to aid in evaluation of specific water-quality issues (understanding well). The groundwater samples were analyzed for a large number of organic constituents (volatile organic compounds [VOCs], gasoline additives and degradates, pesticides and pesticide degradates, fumigants, and pharmaceutical compounds), constituents of special interest (perchlorate, N-nitrosodimethylamine [NDMA], and 1,2,3-trichloropropane [1,2,3-TCP]), naturally occurring inorganic constituents (nutrients, major and minor ions, and trace elements), and radioactive constituents (gross alpha and gross beta radioactivity, radium isotopes, and radon-222). Naturally occurring isotopes (strontium, tritium, and carbon-14, and stable isotopes of hydrogen and oxygen in water), and dissolved noble gases also were measured to help identify the sources and ages of the sampled groundwater. In total, 239 constituents and water-quality indicators (field parameters) were investigated. Quality-control samples (blanks, replicates, and samples for matrix spikes) were collected at 12 percent of the wells, and the results for these samples were used to evaluate the quality of the data for the groundwater samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that contamination was not a noticeable source of bias in the data for the groundwater samples. Differences between replicate samples generally were within acceptable ranges, indicating acceptably low variability. Matrix spike recoveries were within acceptable ranges for most compoundsThis study did not evaluate the quality of water delivered to consumers; after withdrawal from the ground, water typically is treated, disinfected, or blended with other waters to maintain water quality. Regulatory thresholds apply to water that is served to the consumer, not to raw groundwater. However, to provide some context for the results, concentrations of constituents measured in the raw groundwater were compared with regulatory and non-regulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and California Department of Public Health (CDPH) and thresholds established for aesthetic concerns (secondary maximum contaminant levels, SMCL-CA) by CDPH. Comparisons between data collected for this study and drinking-water thresholds are for illustrative purposes only, and are not indicative of compliance or non-compliance with drinking water standards. Most constituents that were detected in groundwater samples were found at concentrations below drinking-water thresholds. Volatile organic compounds (VOCs) were detected in about one-half of the samples and pesticides detected in about one-third of the samples; all detections of these constituents were below health-based thresholds. Most detections of trace elements and nutrients in samples from ANT wells were below health-based thresholds. Exceptions include: one detection of nitrite plus nitr
The information gained from witnesses' responses to an initial "blank" lineup.
Palmer, Matthew A; Brewer, Neil; Weber, Nathan
2012-10-01
Wells ("The psychology of lineup identifications," Journal of Applied Social Psychology, 1984, 14, 89-103) proposed that a blank lineup (an initial lineup of known-to-be-innocent foils) can be used to screen eyewitnesses; witnesses who chose from a blank lineup (initial choosers) were more likely to make an error on a second lineup that contained a suspect than were witnesses who rejected a blank lineup (initial nonchoosers). Recent technological advances (e.g., computer-administered lineups) may overcome many of the practical difficulties cited as a barrier to the use of blank lineups. Our research extended knowledge about the blank lineup procedure by investigating the underlying causes of the difference in identification performance between initial choosers and initial nonchoosers. Studies 1a and 1b (total, N = 303) demonstrated that initial choosers were more likely to reject a second lineup than initial nonchoosers and witnesses who did not view a blank lineup, implying that cognitive biases (e.g., confirmation bias and commitment effects) influenced initial choosers' identification decisions. In Study 2 (N = 200), responses on a forced-choice identification test provided evidence that initial choosers have, on average, poorer memories for the culprit than do initial nonchoosers. We also investigated the usefulness of blank lineups for interpreting identification evidence. Diagnosticity ratios suggested that suspect identifications made by initial nonchoosers (cf. initial choosers) should have a greater impact on estimates of the likely guilt of the suspect. Furthermore, for initial nonchoosers, higher confidence in blank lineup rejections was associated with higher diagnosticity for subsequent suspect identifications. These results have implications for policy to guide the collection and interpretation of identification evidence. PsycINFO Database Record (c) 2012 APA, all rights reserved.
Tank 40 Final Sludge Batch 8 Chemical Characterization Results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bannochie, Christopher J.
2013-09-19
A sample of Sludge Batch 8 (SB8) was pulled from Tank 40 in order to obtain radionuclide inventory analyses necessary for compliance with the Waste Acceptance Product Specifications (WAPS). The SB8 WAPS sample was also analyzed for chemical composition, including noble metals, and fissile constituents, and these results are reported here. These analyses along with the WAPS radionuclide analyses will help define the composition of the sludge in Tank 40 that is currently being fed to the Defense Waste Processing Facility (DWPF) as SB8. At SRNL, the 3-L Tank 40 SB8 sample was transferred from the shipping container into amore » 4-L high density polyethylene bottle and solids were allowed to settle. Supernate was then siphoned off and circulated through the shipping container to complete the transfer of the sample. Following thorough mixing of the 3-L sample, a 553 g sub-sample was removed. This sub-sample was then utilized for all subsequent slurry sample preparations. Eight separate aliquots of the slurry were digested, four with HNO{sub 3}/HCl (aqua regia) in sealed Teflon(r) vessels and four with NaOH/Na{sub 2}O{sub 2} (alkali or peroxide fusion) using Zr crucibles. Two Analytical Reference Glass - 1 (ARG-1) standards were digested along with a blank for each preparation. Each aqua regia digestion and blank was diluted to 1:100 mL with deionized water and submitted to Analytical Development (AD) for inductively coupled plasma - atomic emission spectroscopy (ICP-AES) analysis, inductively coupled plasma - mass spectrometry (ICP-MS) analysis, atomic absorption spectroscopy (AA) for As and Se, and cold vapor atomic absorption spectroscopy (CV-AA) for Hg. Equivalent dilutions of the alkali fusion digestions and blank were submitted to AD for ICP-AES analysis. Tank 40 SB8 supernate was collected from a mixed slurry sample in the SRNL Shielded Cells and submitted to AD for ICP-AES, ion chromatography (IC), total base/free OH-/other base, total inorganic carbon/total organic carbon (TIC/TOC) analyses. Weighted dilutions of slurry were submitted for IC, TIC/TOC, and total base/free OH-/other base analyses. Activities for U-233, U-235, and Pu-239 were determined from the ICP-MS data for the aqua regia digestions of the Tank 40 WAPS slurry using the specific activity of each isotope. The Pu-241 value was determined from a Pu-238/-241 method developed by SRNL AD and previously described.« less
Tank 40 final sludge batch 9 chemical and fissile radionuclide characterization results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bannochie, C. J.; Kubilius, W. P.; Pareizs, J. M.
A sample of Sludge Batch (SB) 9 was pulled from Tank 40 in order to obtain radionuclide inventory analyses necessary for compliance with the Waste Acceptance Product Specifications (WAPS)i. The SB9 WAPS sample was also analyzed for chemical composition, including noble metals, and fissile constituents, and these results are reported here. These analyses along with the WAPS radionuclide analyses will help define the composition of the sludge in Tank 40 that is fed to the Defense Waste Processing Facility (DWPF) as SB9. At the Savannah River National Laboratory (SRNL), the 3-L Tank 40 SB9 sample was transferred from the shippingmore » container into a 4-L high density polyethylene bottle and solids were allowed to settle. Supernate was then siphoned off and circulated through the shipping container to complete the transfer of the sample. Following thorough mixing of the 3-L sample, a 547 g sub-sample was removed. This sub-sample was then utilized for all subsequent slurry sample preparations. Eight separate aliquots of the slurry were digested, four with HNO3/HCl (aqua regiaii) in sealed Teflon® vessels and four with NaOH/Na2O2 (alkali or peroxide fusioniii) using Zr crucibles. Three Analytical Reference Glass – 1iv (ARG-1) standards were digested along with a blank for each preparation. Each aqua regia digestion and blank was diluted to 1:100 with deionized water and submitted to Analytical Development (AD) for inductively coupled plasma – atomic emission spectroscopy (ICP-AES) analysis, inductively coupled plasma – mass spectrometry (ICP-MS) analysis, atomic absorption spectroscopy (AA) for As and Se, and cold vapor atomic absorption spectroscopy (CV-AA) for Hg. Equivalent dilutions of the alkali fusion digestions and blank were submitted to AD for ICP-AES analysis. Tank 40 SB9 supernate was collected from a mixed slurry sample in the SRNL Shielded Cells and submitted to AD for ICP-AES, ion chromatography (IC), total base/free OH-/other base, total inorganic carbon/total organic carbon (TIC/TOC) analyses. Weighted dilutions of slurry were submitted for IC, TIC/TOC, and total base/free OH-/other base analyses. Activities for U-233, U-235, and Pu-239 were determined from the ICP-MS data for the aqua regia digestions of the SB9 WAPS slurry using the specific activity of each isotope. The Pu-241 value was determined from a Pu-238/-241 method developed by SRNL AD and previously described.v« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xianliang, Zhou; Mopper, K.
1990-10-01
Carbonyl compounds in clean marine air were trapped onto 2,4-dinitrophenylhydrazine- (DNPH-) coated cartridges, and their hydrazone derivatives were separated by HPLC and detected by UV absorbance. More than 20 carbonyl compounds were isolated from marine air with >92% collection efficiency. The technique employs a highly effective reagent purification procedure, which results in much lower blanks compared to previously reported trapping techniques for carbonyl compounds. Blanks were routinely <0.07 ppb for formaldehyde and acetone and <0.02 ppb for the others. Humidity and reactive gases have no detectable effect on collection efficiencies. Carbonyl-DNPH derivatives eluted from the cartridges are stable in acetonitrilemore » for at least 2 weeks, which facilitates field studies. Several previously undetected unknown carbonyl compounds were found in marine air by this technique. Typical results for open ocean and coastal marine air are shown.« less
X-Ray Spectra of Quasars from the ROSAT Public Archive
NASA Technical Reports Server (NTRS)
Elvis, Martin S.; West, Donald (Technical Monitor)
2000-01-01
This has been a most productive proposal. We have: (1) Found many new X-ray absorbed quasars at z>2; (2) Determined that all of these are radio-loud, favoring an intrinsic origin for the absorption; (3) Found that the one radio-quiet exception lay close to a nearby galaxy, so initiating the X-ray study of the ISM of normal galaxies via X-ray spectroscopy; (4) Discovered a class of 'red quasars', probably the tip of a large obscured population; and (5) Discovered a class of 'blank field X-ray sources'. These are a heterogeneous collection but probably include several peculiar types of active galactic nuclei (AGN). Follow-up of the 'blanks' is being undertaken under a separate ADP program. Chandra and XMM-Newton observing time for these objects has been approved. This program has produced six refereed papers and six published conference proceedings.
Piezoelectric resonator assembly with thin molybdenum mounting clips
Peters, R. Donald
1981-01-01
A resonator mounting assembly wherein the resonator blank is mounted agai an essentially planar surface presented by a plurality of peripherally disposed mounting clips and bonded to this surface to provide substantially all the mechanical support for the blank in a direction normal to the major faces of the resonator blank, while being flexible in the directions parallel to said major faces so as to minimize radial stresses on the resonator blank, particularly during thermal cycling of the resonator assembly. The clips are fabricated of a low thermal expansion material, such as molybdenum, which also has considerable yield strength after exposure to processing temperatures; the bonding of the clips to the edges of the resonator blank can be achieved by a polyimide containing electrically conductive particles.
ERIC Educational Resources Information Center
Blonigen, Daniel M.; Patrick, Christopher J.; Gasperi, Marianna; Steffen, Benjamin; Ones, Deniz S.; Arvey, Richard D.; de Oliveira Baumgartl, Viviane; do Nascimento, Elizabeth
2011-01-01
Integrity testing has long been utilized in personnel selection to screen for tendencies toward counterproductive workplace behaviors. The construct of externalizing from the psychopathology literature represents a coherent spectrum marked by disinhibitory traits and behaviors. The present study drew on a sample of male and female undergraduates…
21 CFR 177.1950 - Vinyl chloride-ethylene copolymers.
Code of Federal Regulations, 2014 CFR
2014-04-01
... in cyclohexanone at 30 °C is not less than 0.50 deciliter per gram as determined by ASTM method D1243... copol-ymer per 100 grams of sample tested as determined from the organic chlorine content. The organic... extractives. All determinations shall be done in duplicate using duplicate blanks. Approximately 400 grams of...
Code of Federal Regulations, 2012 CFR
2012-07-01
... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) GUIDELINES ESTABLISHING TEST PROCEDURES... to a wide variety of sample types ranging from reagent (blank) water containing analyte to wastewater... times the standard deviation of replicate instrumental measurements of the analyte in reagent water. (c...
Influence of preconsolidation on consolidation quality after stamp forming of C/PEEK composites
NASA Astrophysics Data System (ADS)
Slange, T. K.; Warnet, L.; Grouve, W. J. B.; Akkerman, R.
2016-10-01
Stamp forming is a rapid manufacturing technology used to shape flat blanks of thermoplastic composite material into three-dimensional components. Currently, expensive autoclave and press consolidation are used to preconsolidate blanks. This study investigates the influence of preconsolidation on final consolidation quality after stamp forming and explores the potential of alternative blank manufacturing methods that could reduce part costs. Blanks were manufactured using various blank manufacturing methods and subsequently were stamp formed. The consolidation quality both before and after stamp forming was compared, where the focus was on void content as the main measure for consolidation quality. The void content was characterized through thickness and density measurements, as well as by microscopy analysis. Results indicate that preconsolidation quality does have an influence on the final consolidation quality. This is due to the severe deconsolidation and limited reconsolidation during stamp forming. Nevertheless, the potential of automated fiber placement and ultrasonic spot welding as alternative blank manufacturing methods was demonstrated.
Nuclear Forensic Field Exercise #1
2006-11-01
Ottawa; novembre 2006. Introduction ou contexte Un exercice radiologique pratique a été organisé à l’appui du projet 04-0030TD de l’IRTC. Les...11 List of symbols/abbreviations/acronyms/initialisms ..................................................................... 13 viii DRDC...R&D Canada - Ottawa. 12 DRDC Ottawa TM 2006-214 This page intentionally left blank. DRDC Ottawa TM 2006-214 13 List of symbols/abbreviations
Tuck, L.K.; Dutton, D.M.; Nimick, D.A.
1997-01-01
Geothermal waters in Yellowstone National Park contribute large quantities of arsenic to the headwaters of the Madison River. Water in some Quaternary and Tertiary valley-fill deposits along the Madison and upper Missouri Rivers also is locally enriched in arsenic. Arsenic in surface and ground water in these valleys is an important public- health concern because arsenic concentrations frequently exceed the State of Montana water- quality human health standard of 18 micrograms per liter as well as the U.S. Environmental Protection Agency Maximum Contaminant Level of 50 micrograms per liter. This report presents hydrologic and water-quality data for the Madison and upper Missouri Rivers and selected tributaries, irrigation supply canals or ditches, drains, springs and seeps, for Lake Helena, and for ground water in adjacent areas. Hydrologic and water-quality data were collected and compiled to provide information to more fully understand the extent, magnitude, and source of arsenic in surface and ground water along the Madison and upper Missouri Rivers; to assess, to the extent possible, the mechanisms that control arsenic concentrations; and to assess the effect of irrigation on arsenic concentrations. Hydrologic and arsenic- concentration data were collected by the U.S. Geological Survey and other agencies for 104 surface-water sites and 273 ground-water sites during this and previous studies. The quality of analytical results for arsenic concentrations was evaluated by quality-control samples that were submitted from the field and analyzed in the laboratory with routing samples. Quality-control samples consisted of replicates, standard reference samples, interlaboratory comparison samples, and field blanks.
Bennett, Peter A.; Bennett, George L.; Belitz, Kenneth
2009-01-01
Groundwater quality in the approximately 1,180-square-mile Northern Sacramento Valley study unit (REDSAC) was investigated in October 2007 through January 2008 as part of the Priority Basin Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin Project was developed in response to the Groundwater Quality Monitoring Act of 2001, and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The study was designed to provide a spatially unbiased assessment of the quality of raw groundwater used for public water supplies within REDSAC and to facilitate statistically consistent comparisons of groundwater quality throughout California. Samples were collected from 66 wells in Shasta and Tehama Counties. Forty-three of the wells were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study area (grid wells), and 23 were selected to aid in evaluation of specific water-quality issues (understanding wells). The groundwater samples were analyzed for a large number of synthetic organic constituents (volatile organic compounds [VOC], pesticides and pesticide degradates, and pharmaceutical compounds), constituents of special interest (perchlorate and N-nitrosodimethylamine [NDMA]), naturally occurring inorganic constituents (nutrients, major and minor ions, and trace elements), radioactive constituents, and microbial constituents. Naturally occurring isotopes (tritium, and carbon-14, and stable isotopes of nitrogen and oxygen in nitrate, stable isotopes of hydrogen and oxygen of water), and dissolved noble gases also were measured to help identify the sources and ages of the sampled ground water. In total, over 275 constituents and field water-quality indicators were investigated. Three types of quality-control samples (blanks, replicates, and sampmatrix spikes) were collected at approximately 8 to 11 percent of the wells, and the results for these samples were used to evaluate the quality of the data obtained from the groundwater samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that contamination was not a noticeable source of bias in the data for the groundwater samples. Differences between replicate samples were within acceptable ranges for nearly all compounds, indicating acceptably low variability. Matrix-spike recoveries were within acceptable ranges for most compounds. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, raw groundwater typically is treated, disinfected, or blended with other waters to maintain water quality. Regulatory thresholds apply to water that is served to the consumer, not to raw ground water. However, to provide some context for the results, concentrations of constituents measured in the raw groundwater were compared with regulatory and nonregulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and California Department of Public Health (CDPH) and with aesthetic and technical thresholds established by CDPH. Comparisons between data collected for this study and drinking-water thresholds are for illustrative purposes only and do not indicate compliance or noncompliance with those thresholds. The concentrations of most constituents detected in groundwater samples from REDSAC were below drinking-water thresholds. Volatile organic compounds (VOC) and pesticides were detected in less than one-quarter of the samples and were generally less than a hundredth of any health-based thresholds. NDMA was detected in one grid well above the NL-CA. Concentrations of all nutrients and trace elements in samples from REDSAC wells were below the health-based thresholds except those of arsenic in three samples, which were above the USEPA maximum contaminant level (MCL-US). However
Eger, J E; Hamm, R L; Demark, J J; Chin-Heady, E; Tolley, M P; Benson, E P; Zungoli, P A; Smith, M S; Spomer, N A
2014-06-01
A durable termite bait containing 0.5% noviflumuron was evaluated for physical durability, retention of active ingredient, consumption by termites, and toxicity to termites over 5 yr in field studies at locations in Indiana, Mississippi, and South Carolina. Plots in Indiana and Mississippi included both natural rainfall and irrigated plots, while plots in South Carolina received only natural rainfall. Samples collected every 3 mo for the first 4 yr were evaluated for consumption with a 7 d no-choice bioassay using Reticulitermes flavipes (Kollar). Consumption and toxicity of 5 yr samples were evaluated in similar bioassays conducted for 42 d. Durable baits received from field sites had some cracking, and a small amount of external flaking, but no major deterioration based on visual observation. There were no significant differences in noviflumuron concentration over the 5-yr period and no trend toward reduced concentrations of noviflumuron over time. Consumption of aged durable baits over 4 yr was variable, but termites usually consumed more aged durable bait than fresh durable bait and the differences were frequently significant. There were some exceptions, but termites consumed significantly more fresh durable bait than aged durable bait in only 4% of observations. When 5 yr samples were evaluated, consumption was lowest for fresh durable bait and termites consumed significantly more aged durable bait from irrigated plots in Indiana and from both natural and irrigated plots in Mississippi than fresh durable bait. Survival of termites fed blank durable bait was significantly higher than that for termites fed any of the baits containing noviflumuron and there were no significant differences in survival among the noviflumuron durable baits. Our results suggest that the bait would be durable for at least 5 yr and possibly longer under most environmental conditions.
ALMA observations of atomic carbon in z ˜ 4 dusty star-forming galaxies
NASA Astrophysics Data System (ADS)
Bothwell, M. S.; Aguirre, J. E.; Aravena, M.; Bethermin, M.; Bisbas, T. G.; Chapman, S. C.; De Breuck, C.; Gonzalez, A. H.; Greve, T. R.; Hezaveh, Y.; Ma, J.; Malkan, M.; Marrone, D. P.; Murphy, E. J.; Spilker, J. S.; Strandet, M.; Vieira, J. D.; Weiß, A.
2017-04-01
We present Atacama Large Millimeter Array [C I](1 - 0) (rest frequency 492 GHz) observations for a sample of 13 strongly lensed dusty star-forming galaxies (DSFGs) originally discovered at 1.4 mm in a blank-field survey by the South Pole Telescope (SPT). We compare these new data with available [C I] observations from the literature, allowing a study of the interstellar medium (ISM) properties of ˜30 extreme DSFGs spanning a redshift range 2 < z < 5. Using the [C I] line as a tracer of the molecular ISM, we find a mean molecular gas mass for SPT-DSFGs of 6.6 × 1010 M⊙. This is in tension with gas masses derived via low-J 12CO and dust masses; bringing the estimates into accordance requires either (a) an elevated CO-to-H2 conversion factor for our sample of αCO ˜ 2.5 and a gas-to-dust ratio ˜200, or (b) an high carbon abundance X_{C I} ˜ 7× 10^{-5}. Using observations of a range of additional atomic and molecular lines (including [C I], [C II]and multiple transitions of CO), we use a modern photodissociation region code (3D-PDR) to assess the physical conditions (including the density, UV radiation field strength and gas temperature) within the ISM of the DSFGs in our sample. We find that the ISM within our DSFGs is characterized by dense gas permeated by strong UV fields. We note that previous efforts to characterize photodissociation region regions in DSFGs may have significantly under-estimated the density of the ISM. Combined, our analysis suggests that the ISM of extreme dusty starbursts at high redshift consists of dense, carbon-rich gas not directly comparable to the ISM of starbursts in the local Universe.
Kabir, Md Humayun; Abd El-Aty, A M; Rahman, Md Musfiqur; Kim, Sung-Woo; Choi, Jeong-Heui; Lee, Young-Jun; Truong, Lieu T B; Lee, Kang-Bong; Kim, Mi-Ra; Shin, Ho-Chul; Shim, Jae-Han
2017-05-01
This study was undertaken to quantify the residue levels and propose the dissipation kinetics of thiacloprid formulated as suspension concentrate in field-incurred Asian pears grown under two different open-field conditions. Samples were extracted with 20% distilled water in acetonitrile; partitioned with brine water and dichloromethane; and purified with a Florisil solid phase extraction cartridge. The analyte was identified with an LC ultraviolet detector, and field-incurred samples were confirmed using LC-MS/MS. The calibration curve was linear over the range 0.05-5.0 mg/L with a satisfactory coefficient of determination (R 2 = 0.9994). The limits of detection and limits of quantification (LOQ) were 0.003 and 0.01 mg/kg, respectively. The recovery rate fortified to blank samples at LOQ, 10× LOQ, and the maximum residue limit (MRL) were between 73.7 and 86.2% with relative standard deviation ≤9.0%. The residual concentrations at both sites were considerably lower than the MRL (0.7 mg/kg) set by the Korean Ministry of Food Drug Safety, with biological half-lives of 5.0 and 7.4 days, for sites 1 and 2, respectively. From the pre-harvest residue limit curve, it was predicted that if the residues were <1.13 or 1.40 mg/kg 10 days before harvest, the residue level would be lower than the MRL during harvest. Risk assessment on day 0 showed an acceptable daily intake (%) of 13.0% and 11.0% for sites 1 and site 2, respectively, which indicates that the residual amounts are not hazardous to the Korean population. Copyright © 2016 John Wiley & Sons, Ltd.
Contamination analyses of technology mirror assembly optical surfaces
NASA Technical Reports Server (NTRS)
Germani, Mark S.
1991-01-01
Automated electron microprobe analyses were performed on tape lift samples from the Technology Mirror Assembly (TMA) optical surfaces. Details of the analyses are given, and the contamination of the mirror surfaces is discussed. Based on the automated analyses of the tape lifts from the TMA surfaces and the control blank, we can conclude that the particles identified on the actual samples were not a result of contamination due to the handling or sampling process itself and that the particles reflect the actual contamination on the surface of the mirror.
Ultra-Low Level Plutonium Isotopes in the NIST SRM 4355A (Peruvian Soil-1)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Inn, Kenneth G.; LaRosa, Jerome; Nour, Svetlana
2009-05-31
For more than 20 years, countries and their agencies which monitor discharge sites and storage facilities have relied on the National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 4355 Peruvian Soil reference material. Its low fallout contamination makes it an ideal soil blank for measurements associated with terrestrial pathway to man studies. Presently, SRM 4355 is out of stock, and a new batch of the Peruvian soil is currently under development as future NIST SRM 4355A. Both environmental radioanalytical laboratories and mass spectrometry communities will benefit from this SRM. The former must assess their laboratory contamination andmore » measurement detection limits by measurement of blank sample material. The Peruvian Soil is so low in anthropogenic radionuclides that it is a suitable virtual blank. On the other hand, mass spectrometric laboratories have high sensitivity instruments that are capable of quantitative isotopic measurements at low plutonium levels of the SRM 4355 (first Peruvian Soil SRM) that provided the mass spectrometric community with the calibration, quality control, and testing material needed for methods development, and legal defensibility. The quantification of the ultra-low plutonium content in the SRM 4355A was a considerable challenge for the mass spectrometric laboratories. Careful blank control and correction, isobaric interferences, instrument stability, peak assessment, and detection assessment were necessary. Furthermore, a systematic statistical evaluation of the measurement results and considerable discussions with the mass spectroscopy metrologists were needed to derive the certified values and uncertainties. SRM 4355A will provide the mass spectrometric community with the quality control and testing material needed for higher sensitivity methods development, and legal defensibility.« less
The integrated water balance and soil data set of the Rollesbroich hydrological observatory
NASA Astrophysics Data System (ADS)
Qu, Wei; Bogena, Heye R.; Huisman, Johan A.; Schmidt, Marius; Kunkel, Ralf; Weuthen, Ansgar; Schiedung, Henning; Schilling, Bernd; Sorg, Jürgen; Vereecken, Harry
2016-10-01
The Rollesbroich headwater catchment located in western Germany is a densely instrumented hydrological observatory and part of the TERENO (Terrestrial Environmental Observatories) initiative. The measurements acquired in this observatory present a comprehensive data set that contains key hydrological fluxes in addition to important hydrological states and properties. Meteorological data (i.e., precipitation, air temperature, air humidity, radiation components, and wind speed) are continuously recorded and actual evapotranspiration is measured using the eddy covariance technique. Runoff is measured at the catchment outlet with a gauging station. In addition, spatiotemporal variations in soil water content and temperature are measured at high resolution with a wireless sensor network (SoilNet). Soil physical properties were determined using standard laboratory procedures from samples taken at a large number of locations in the catchment. This comprehensive data set can be used to validate remote sensing retrievals and hydrological models, to improve the understanding of spatial temporal dynamics of soil water content, to optimize data assimilation and inverse techniques for hydrological models, and to develop upscaling and downscaling procedures of soil water content information. The complete data set is freely available online (http://www.tereno.net, doi:10.5880/TERENO.2016.001, doi:10.5880/TERENO.2016.004, doi:10.5880/TERENO.2016.003) and additionally referenced by three persistent identifiers securing the long-term data and metadata availability.
Ultra-low level plutonium isotopes in the NIST SRM 4355A (Peruvian Soil-1).
Inn, Kenneth G W; LaRosa, Jerome; Nour, Svetlana; Brooks, George; LaMont, Steve; Steiner, Rob; Williams, Ross; Patton, Brad; Bostick, Debbie; Eiden, Gregory; Petersen, Steve; Douglas, Matthew; Beals, Donna; Cadieux, James; Hall, Greg; Goldberg, Steve; Vogt, Stephan
2009-05-01
For more than 20 years, countries and their agencies which monitor radionuclide discharge sites and storage facilities have relied on the National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 4355 Peruvian Soil. Its low fallout contamination makes it an ideal soil blank for measurements associated with terrestrial-pathway-to-man studies. Presently, SRM 4355 is out of stock, and a new batch of the Peruvian soil is currently under development as future NIST SRM 4355A. Both environmental radioanalytical laboratories and mass spectrometry communities will benefit from the use of this SRM. The former must assess their laboratory procedural contamination and measurement detection limits by measurement of blank sample material. The Peruvian Soil is so low in anthropogenic radionuclide content that it is a suitable virtual blank. On the other hand, mass spectrometric laboratories have high sensitivity instruments that are capable of quantitative isotopic measurements at low plutonium levels in the SRM 4355 (first Peruvian Soil SRM) that provided the mass spectrometric community with the calibration, quality control, and testing material needed for methods development and legal defensibility. The quantification of the ultra-low plutonium content in the SRM 4355A was a considerable challenge for the mass spectrometric laboratories. Careful blank control and correction, isobaric interferences, instrument stability, peak assessment, and detection assessment were necessary. Furthermore, a systematic statistical evaluation of the measurement results and considerable discussions with the mass spectroscopy metrologists were needed to derive the certified values and uncertainties. The one sided upper limit of the 95% tolerance with 95% confidence for the massic (239)Pu content in SRM 4355A is estimated to be 54,000 atoms/g.
Tissue floaters and contaminants in the histology laboratory.
Platt, Eric; Sommer, Paul; McDonald, Linda; Bennett, Ana; Hunt, Jennifer
2009-06-01
Anatomic pathology diagnosis is often based on morphologic features. In recent years, an appropriate increased attention to patient safety has led to an emphasis on improving maintenance of patient identity. Decreasing or eliminating cross-contamination from one specimen to another is an example of a patient identity issue for which process improvement can be initiated. To quantify the presence of cross-contamination from histology water baths and the slide stainers. We assessed for the presence of contaminants in water baths at cutting stations and in linear stainer stain baths. We assessed the potential for tissue discohesion and carryover in tissue samples and we assessed the potential for carryover onto blank slides sent through the stainer. In the 13 water baths examined (totalling 195 L of water), only one fragment of tissue was identified. The stain baths, however, contained abundant tissue contaminants, ranging in size from 2 to 3 cells to hundreds of cells. The first sets of xylenes and alcohols were the most heavily contaminated. Cross-contamination to blank slides occurred at a rate of 8%, with the highest frequency in the late afternoon. Cross-contamination can present a significant challenge in the histology laboratory. Although the histotechnologists' water baths are not heavily contaminated, the stainer baths do contain contaminating tissue fragments. Cross-contamination does occur onto blank slides in the experimental setting.
3D finite element modelling of sheet metal blanking process
NASA Astrophysics Data System (ADS)
Bohdal, Lukasz; Kukielka, Leon; Chodor, Jaroslaw; Kulakowska, Agnieszka; Patyk, Radoslaw; Kaldunski, Pawel
2018-05-01
The shearing process such as the blanking of sheet metals has been used often to prepare workpieces for subsequent forming operations. The use of FEM simulation is increasing for investigation and optimizing the blanking process. In the current literature a blanking FEM simulations for the limited capability and large computational cost of the three dimensional (3D) analysis has been largely limited to two dimensional (2D) plane axis-symmetry problems. However, a significant progress in modelling which takes into account the influence of real material (e.g. microstructure of the material), physical and technological conditions can be obtained by using 3D numerical analysis methods in this area. The objective of this paper is to present 3D finite element analysis of the ductile fracture, strain distribution and stress in blanking process with the assumption geometrical and physical nonlinearities. The physical, mathematical and computer model of the process are elaborated. Dynamic effects, mechanical coupling, constitutive damage law and contact friction are taken into account. The application in ANSYS/LS-DYNA program is elaborated. The effect of the main process parameter a blanking clearance on the deformation of 1018 steel and quality of the blank's sheared edge is analyzed. The results of computer simulations can be used to forecasting quality of the final parts optimization.
Di Fusco, Massimo; Federico, Rodolfo; Boffi, Alberto; Macone, Alberto; Favero, Gabriele; Mazzei, Franco
2011-08-01
In this work, we have characterized a diamine oxidase (DAO) from Lathyrus sativus and evaluated its use, for the first time, as biocatalytic component of an electrochemical biosensor for the determination of biogenic amines index in wine and beer samples. Firstly, DAO was electrokinetically characterized free in solution by means of a platinum electrode and then immobilized by using polyazetidine prepolimer on the surface of screen-printed electrodes constituted of two gold working electrodes. The amperometric measurements were carried out by using a flow system at a fixed potential of +600 mV vs the internal silver pseudo reference in phosphate buffer solution (0.1 mol l(-1), pH = 7.4). The analysis of wine and beer samples were performed in flow injection system using the dual channel transducer providing simultaneous detection of sample and blank signal, and the resulting signal (after subtraction of the blank signal) was referred to that of putrescine. The results were compared with those obtained using a modified reference method based on gas chromatography-mass spectrometry analysis on the same samples. The results obtained in the analysis of Italian wines shows the better suitability of DAO-based biosensor in the determination of the biogenic amines (BAs) index expressed as putrescine equivalent in both red and white wines, being less efficient in beer samples where it underestimates by about 50% the BAs content.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 4 2013-10-01 2013-10-01 false Telecommunications Service on the Vertical Blanking Interval and in the Visual Signal. 73.646 Section 73.646 Telecommunication FEDERAL COMMUNICATIONS....646 Telecommunications Service on the Vertical Blanking Interval and in the Visual Signal. (a...
Method for forming a liquid cooled airfoil for a gas turbine
Grondahl, Clayton M.; Willmott, Leo C.; Muth, Myron C.
1981-01-01
A method for forming a liquid cooled airfoil for a gas turbine is disclosed. A plurality of holes are formed at spaced locations in an oversized airfoil blank. A pre-formed composite liquid coolant tube is bonded into each of the holes. The composite tube includes an inner member formed of an anti-corrosive material and an outer member formed of a material exhibiting a high degree of thermal conductivity. After the coolant tubes have been bonded to the airfoil blank, the airfoil blank is machined to a desired shape, such that a portion of the outer member of each of the composite tubes is contiguous with the outer surface of the machined airfoil blank. Finally, an external skin is bonded to the exposed outer surface of both the machined airfoil blank and the composite tubes.
Emergency Medical Care. A Manual for the Paramedic in the Field--Workbook.
ERIC Educational Resources Information Center
National Highway Traffic Safety Administration (DOT), Washington, DC.
This workbook is designed to accompany the text of the same name and to serve as an aid to both learning and review during the course of study. The workbook consists of 15 module self-tests and vocabulary lists that follow the modules of the text. Tests consist of objective questions (multiple choice, fill-in-the-blank, short answers, and…
Witt, E. C.; Hippe, D.J.; Giovannitti, R.M.
1992-01-01
A total of 304 nutrient samples were collected from May 1990 through September 1991 to determine concentrations and loads of nutrients in water discharged from two spring basins in Cumberland County, Pa. Fifty-four percent of these nutrient samples were for the evaluation of (1) laboratory consistency, (2) container and preservative cleanliness, (3) maintenance of analyte representativeness as affected by three different preservation methods, and (4) comparison of analyte results with the "Most Probable Value" for Standard Reference Water Samples. Results of 37 duplicate analyses indicate that the Pennsylvania Department of Environmental Resources, Bureau of Laboratories (principal laboratory) remained within its ±10 percent goal for all but one analyte. Results of the blank analysis show that the sampling containers did not compromise the water quality. However, mercuric-chloride-preservation blanks apparently contained measurable ammonium in four of five samples and ammonium plus organic nitrogen in two of five samples. Interlaboratory results indicate substantial differences in the determination of nitrate and ammonium plus organic nitrogen between the principal laboratory and the U.S. Geological Survey National Water-Quality Laboratory. In comparison with the U.S. Environmental Protection Agency Quality-Control Samples, the principal laboratory was sufficiently accurate in its determination of nutrient anafytes. Analysis of replicate samples indicated that sulfuric-acid preservative best maintained the representativeness of the anafytes nitrate and ammonium plus organic nitrogen, whereas, mercuric chloride best maintained the representativeness of orthophosphate. Comparison of nutrient analyte determinations with the Most Probable Value for each preservation method shows that two of five analytes with no chemical preservative compare well, three of five with mercuric-chloride preservative compare well, and three of five with sulfuricacid preservative compare well.
Ranalli, Anthony J.
2008-01-01
The Pine River Watershed Stakeholders Group was created in December 1997 to allow local participation in addressing water-quality issues in Los Pi?os River watershed, including Vallecito Reservoir in southwestern Colorado. One water-quality issue identified by the stakeholder group is to increase the understanding of the current water quality of Vallecito Reservoir, its two major inflows, and its outflow. The U.S. Geological Survey (USGS), in cooperation with volunteers from the Pine River Watershed Stakeholders Group and the U.S. Environmental Protection Agency (USEPA), U.S. Bureau of Reclamation (BOR), Colorado Department of Public Health and Environment (CDPHE), Pine River Irrigation District, Southern Ute Tribe, San Juan Basin Health Department, and San Juan Resource Conservation and Development, collected water-quality samples from Vallecito Reservoir, its two major inflows, and its outflow between August 1999 and November 2002 at about monthly intervals from April through November. The water-quality samples were analyzed for total and dissolved metals (aluminum, arsenic, cadmium, copper, chromium, iron, lead, manganese, mercury, nickel, silver, and zinc), dissolved major ions (calcium, magnesium, sodium, potassium, chloride, bicarbonate, and sulfate), dissolved silica, dissolved organic carbon (DOC), ultraviolet (UV) absorbance at 254 and 280 nanometers, nutrients (total organic nitrogen, dissolved organic nitrogen, dissolved ammonia, dissolved nitrate, total phosphorus, dissolved phosphorus, and orthophosphate), chlorophyll-a (reservoir only), and suspended sediment (inlets to the reservoir only). Measurements of field properties (pH, specific conductance, water temperature, and dissolved oxygen) were also made at each sampling site each time a water-quality sample was collected. This report documents (1) sampling sites and times of sample collection, (2) sample-collection methods, (3) laboratory analytical methods, and (4) responsibilities of each agency/group involved in the project. The report also provides the environmental and quality-control data collected during the project and provides an interpretation of the quality-control data (field blanks and field duplicates) to assess the quality of the environmental data. This report provides a baseline data set against which future changes in water quality can be assessed.
Mann, L.J.
1990-01-01
Groundwater samples from 38 wells at the Idaho National Engineering Laboratory were analyzed for 36 purgeable organic compounds in 1988-89. Thirty-six of the wells obtain water from the Snake River Plain aquifer and were equipped with dedicated or portable pumps. Water samples from one well that obtains water from the aquifer and one that obtains water from a perched groundwater zone were collected using a thief sampler. Analyses of water from 22 wells indicated the aquifer locally contained detectable concentrations of at least 1 of 19 purgeable organic compounds, mainly carbon tetrachloride, 1,1,1-trichloroethane, and trichloroethylene. Except for five wells, the maximum concentration of a specific compound in groundwater was 6.4 microgram/L or less; concentrations of most compounds were less than 0.2 microgram/L. Water from four wells at and near the Test Area North contained from 44 to 29, 000 micrograms/L of trichloroethylene. Water from a well that obtains water from a discontinuous perched groundwater zone at the Radioactive Waste Management Complex contained 1,400 micrograms/L of carbon tetrachloride, 940 micrograms/L of chloroform, 250 micrograms/L of 1,1,1- trichloroethane, and 1,100 micrograms/L trichloroethylene. Selected purgeable organic compounds, such as total xylene and methylene chloride, were detected in some groundwater samples and some blank samples consisting of boiled deionized water. Their presence in the blank samples suggest the compounds could have been inadvertently introduced into the groundwater sampled during or subsequent to collection. (USGS)
SEMATECH produces defect-free EUV mask blanks: defect yield and immediate challenges
NASA Astrophysics Data System (ADS)
Antohe, Alin O.; Balachandran, Dave; He, Long; Kearney, Patrick; Karumuri, Anil; Goodwin, Frank; Cummings, Kevin
2015-03-01
Availability of defect-free reflective mask has been one of the most critical challenges to extreme ultraviolet lithography (EUVL). To mitigate the risk, significant progress has been made on defect detection, pattern shifting, and defect repair. Clearly such mitigation strategies are based on the assumption that defect counts and sizes from incoming mask blanks must be below practical levels depending on mask specifics. The leading industry consensus for early mask product development is that there should be no defects greater than 80 nm in the quality area, 132 mm x 132 mm. In addition less than 10 defects smaller than 80 nm may be mitigable. SEMATECH has been focused on EUV mask blank defect reduction using Veeco Nexus TM IBD platform, the industry standard for mask blank production, and assessing if IBD technology can be evolved to a manufacturing solution. SEMATECH has recently announced a breakthrough reduction of defects in the mask blank deposition process resulting in the production of two defect-free EUV mask blanks at 54 nm inspection sensitivity (SiO2 equivalent). This paper will discuss the dramatic reduction of baseline EUV mask blank defects, review the current deposition process run and compare results with previous process runs. Likely causes of remaining defects will be discussed based on analyses as characterized by their compositions and whether defects are embedded in the multilayer stack or non-embedded.
When the Ostrich-Algorithm Fails: Blanking Method Affects Spike Train Statistics.
Joseph, Kevin; Mottaghi, Soheil; Christ, Olaf; Feuerstein, Thomas J; Hofmann, Ulrich G
2018-01-01
Modern electroceuticals are bound to employ the usage of electrical high frequency (130-180 Hz) stimulation carried out under closed loop control, most prominent in the case of movement disorders. However, particular challenges are faced when electrical recordings of neuronal tissue are carried out during high frequency electrical stimulation, both in-vivo and in-vitro . This stimulation produces undesired artifacts and can render the recorded signal only partially useful. The extent of these artifacts is often reduced by temporarily grounding the recording input during stimulation pulses. In the following study, we quantify the effects of this method, "blanking," on the spike count and spike train statistics. Starting from a theoretical standpoint, we calculate a loss in the absolute number of action potentials, depending on: width of the blanking window, frequency of stimulation, and intrinsic neuronal activity. These calculations were then corroborated by actual high signal to noise ratio (SNR) single cell recordings. We state that, for clinically relevant frequencies of 130 Hz (used for movement disorders) and realistic blanking windows of 2 ms, up to 27% of actual existing spikes are lost. We strongly advice cautioned use of the blanking method when spike rate quantification is attempted. Blanking (artifact removal by temporarily grounding input), depending on recording parameters, can lead to significant spike loss. Very careful use of blanking circuits is advised.
When the Ostrich-Algorithm Fails: Blanking Method Affects Spike Train Statistics
Joseph, Kevin; Mottaghi, Soheil; Christ, Olaf; Feuerstein, Thomas J.; Hofmann, Ulrich G.
2018-01-01
Modern electroceuticals are bound to employ the usage of electrical high frequency (130–180 Hz) stimulation carried out under closed loop control, most prominent in the case of movement disorders. However, particular challenges are faced when electrical recordings of neuronal tissue are carried out during high frequency electrical stimulation, both in-vivo and in-vitro. This stimulation produces undesired artifacts and can render the recorded signal only partially useful. The extent of these artifacts is often reduced by temporarily grounding the recording input during stimulation pulses. In the following study, we quantify the effects of this method, “blanking,” on the spike count and spike train statistics. Starting from a theoretical standpoint, we calculate a loss in the absolute number of action potentials, depending on: width of the blanking window, frequency of stimulation, and intrinsic neuronal activity. These calculations were then corroborated by actual high signal to noise ratio (SNR) single cell recordings. We state that, for clinically relevant frequencies of 130 Hz (used for movement disorders) and realistic blanking windows of 2 ms, up to 27% of actual existing spikes are lost. We strongly advice cautioned use of the blanking method when spike rate quantification is attempted. Impact statement Blanking (artifact removal by temporarily grounding input), depending on recording parameters, can lead to significant spike loss. Very careful use of blanking circuits is advised. PMID:29780301
Laser: a tool for light weight steel solutions for the automotive industry
NASA Astrophysics Data System (ADS)
Prange, Wilfried; Wonneberger, Ingo
2003-03-01
Mid 80th the steel industry discovered the laser as a tool to develop new products made from steel -- the tailored blanks. That means welding single blanks together, which are of different gauge or grades and coating. In the meantime this product is one of the key solutions for light weight vehicles with increasing performances. The market development world wide confirms this statement. But the development of this product is still going on. New high power lasers and new laser generations as Nd:YAG lasers are the basis. Today welded blanks with almost any seam/blank configuration are in high volume production. These blanks offer an additional potential for the optimization of the final product. To produce flat blank is only one possibility. New developments are the tailored tubes as a prematerial for the hydroforming process. This product becomes more and more important for optimized body in white solutions. But this design elements need new solutions in the assembly shops. So the laser is going to get more importance in the 3D welding process as well. This was shown for example in the ULSAB(-AVC)-project. Future vehicles more and more contain different materials. For example the joining of steel and aluminum to Hybrid Blanks can be done successfully by the use of laser. So the laser is one of the most important tools in the future.
Cao, Yi-Juan; Li, Zhen-Bei; Qi, Yu-Juan; Liu, Ying; Gu, Juan; Hu, Fang-Fang; Zhang, Wen-da; Hao, Lin; Hou, Jian-Quan; Han, Cong-Hui
2016-12-01
To investigate the effects of cynomorium songaricum (CS) decoction on the testis weight, serum testosterone level, and sperm parameters of rats with oligoasthenospermia (OAS), explore its action mechanism of improving the proliferation of undifferentiated spermatogonial cells, and provide some experimental and theoretical evidence for the development of new Chinese drugs for OAS. Thirty 8-week-old male SD rats were randomly divided into five groups of equal number: blank control, model control, high-dose CS, medium-dose CS, and low-dose CS. OAS models were established by intraperitoneal injection of cyclophosphamide and, a month later, treated intragastrically with normal saline or CS at 2, 1, and 0.5 g per kg of the body weight per day, all for 4 weeks. Then, the testes of the animals were harvested to obtain the testicular weight, sperm concentration and motility, and the level of serum testosterone (T), detect the expressions of the transcription factor 1 (Oct4), Thy-1 cell surface antigen (Thy1), promyelocytic leukemia zinc finger (PLZF), KIT proto-oncogene receptor tyrosine kinase (C-kit) and glial cell-derived neurotrophic factor (GDNF) in the testis tissue of the rats in the low-dose CS group by real-time PCR. The testis weights in the blank control, model control, high-dose CS, medium-dose CS, and low-dose CS groups were (1.52±0.06), (1.55±0.06), (1.43±0.30), (1.35±0.40) and (1.34±0.04) g, respectively, not significantly different in the blank and model controls from those in the CS groups (P>0.05). The visual field sperm count per 10 HP was significantly increased in the high-, medium-, and low-dose CS groups (202±20, 196±5 and 216±25) as compared with the blank and model controls (200±15 and 134±30) (P<0.05). The mRNA expressions of the Oct4, Thy1, PLZF and GDNF genes were remarkably higher in the low-dose CS group than in the controls (P<0.05), but that of the C-kit gene showed no significant difference from the latter (P>0.05). The visual field sperm motility per 10 HP was markedly increased in the blank control ([52.1±5.5]%), model control ([38.1±2.5]%), high-dose CS ([59.1±9.5]%), medium-dose CS ([58.7±9.5]%), and low-dose CS ([49.6±1.0]%) groups, and so was the level of serum testosterone ([190±87.5], [82.5±25.8], [229±75.6], [331±86.7] and [185±82.4] mmol/L), both remarkably higher in the CS groups than in the model controls (P<0.05) but with no statistically significant difference between the CS groups and the blank controls (P>0.05). CS can significantly improve sperm concentration, sperm motility and serum T level in OAS rats, probably by inducing the expression of GDNF in the rat Sertoli cells, promoting the proliferation of undifferentiated spermatogonial cells, and enhancing spermatogenesis.
Groundwater Quality Data in the Mojave Study Unit, 2008: Results from the California GAMA Program
Mathany, Timothy M.; Belitz, Kenneth
2009-01-01
Groundwater quality in the approximately 1,500 square-mile Mojave (MOJO) study unit was investigated from February to April 2008, as part of the Priority Basin Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin Project was developed in response to the Groundwater Quality Monitoring Act of 2001 and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). MOJO was the 23rd of 37 study units to be sampled as part of the GAMA Priority Basin Project. The MOJO study was designed to provide a spatially unbiased assessment of the quality of untreated ground water used for public water supplies within MOJO, and to facilitate statistically consistent comparisons of groundwater quality throughout California. Samples were collected from 59 wells in San Bernardino and Los Angeles Counties. Fifty-two of the wells were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study area (grid wells), and seven were selected to aid in evaluation of specific water-quality issues (understanding wells). The groundwater samples were analyzed for a large number of organic constituents [volatile organic compounds (VOCs), pesticides and pesticide degradates, and pharmaceutical compounds], constituents of special interest (perchlorate and N-nitrosodimethylamine [NDMA]) naturally occurring inorganic constituents (nutrients, dissolved organic carbon [DOC], major and minor ions, silica, total dissolved solids [TDS], and trace elements), and radioactive constituents (gross alpha and gross beta radioactivity, radium isotopes, and radon-222). Naturally occurring isotopes (stable isotopes of hydrogen, oxygen, and carbon, stable isotopes of nitrogen and oxygen in nitrate, and activities of tritium and carbon-14), and dissolved noble gases also were measured to help identify the sources and ages of the sampled ground water. In total, over 230 constituents and water-quality indicators (field parameters) were investigated. Three types of quality-control samples (blanks, replicates, and matrix spikes) each were collected at approximately 5-8 percent of the wells, and the results for these samples were used to evaluate the quality of the data for the groundwater samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that contamination was not a significant source of bias in the data for the groundwater samples. Differences between replicate samples generally were within acceptable ranges, indicating acceptable analytical reproducibility. Matrix spike recoveries were within acceptable ranges for most compounds. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, untreated groundwater typically is treated, disinfected, or blended with other waters to maintain water quality. Regulatory thresholds apply to water that is served to the consumer, not to untreated ground water. However, to provide some context for the results, concentrations of constituents measured in the untreated ground water were compared with regulatory and non-regulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and California Department of Public Health (CDPH) and thresholds established for aesthetic and technical concerns by CDPH. Comparisons between data collected for this study and thresholds for drinking-water are for illustrative purposes only, and are not indicative of compliance or non-compliance with those thresholds. Most constituents that were detected in groundwater samples in the 59 wells in MOJO were found at concentrations below drinking-water thresholds. In MOJO's 52 grid wells, volatile organic compounds (VOCs) were detected in 40 percent of the wells, and pesticides and pesticide degradates were detected in 23 percent of the grid wel
Quality of nutrient data from streams and ground water sampled during water years 1992-2001
Mueller, David K.; Titus, Cindy J.
2005-01-01
Proper interpretation of water-quality data requires consideration of the effects that bias and variability might have on measured constituent concentrations. In this report, methods are described to estimate the bias due to contamination of samples in the field or laboratory and the variability due to sample collection, processing, shipment, and analysis. Contamination can adversely affect interpretation of measured concentrations in comparison to standards or criteria. Variability can affect interpretation of small differences between individual measurements or mean concentrations. Contamination and variability are determined for nutrient data from quality-control samples (field blanks and replicates) collected as part of the National Water-Quality Assessment (NAWQA) Program during water years 1992-2001. Statistical methods are used to estimate the likelihood of contamination and variability in all samples. Results are presented for five nutrient analytes from stream samples and four nutrient analytes from ground-water samples. Ammonia contamination can add at least 0.04 milligram per liter in up to 5 percent of all samples. This could account for more than 22 percent of measured concentrations at the low range of aquatic-life criteria (0.18 milligram per liter). Orthophosphate contamination, at least 0.019 milligram per liter in up to 5 percent of all samples, could account for more than 38 percent of measured concentrations at the limit to avoid eutrophication (0.05 milligram per liter). Nitrite-plus-nitrate and Kjeldahl nitrogen contamination is less than 0.4 milligram per liter in 99 percent of all samples; thus there is no significant effect on measured concentrations of environmental significance. Sampling variability has little or no effect on reported concentrations of ammonia, nitrite-plus-nitrate, orthophosphate, or total phosphorus sampled after 1998. The potential errors due to sampling variability are greater for the Kjeldahl nitrogen analytes and for total phosphorus sampled before 1999. The uncertainty in a mean of 10 concentrations caused by sampling variability is within a small range (1 to 7 percent) for all nutrients. These results can be applied to interpretation of environmental data collected during water years 1992-2001 in 52 NAWQA study units.
Low-Cost Opportunity for Small-Scale Manufacture of Hardwood Blanks
Bruce G. Hansen; Philip A. Araman
1985-01-01
We analyzed the manufacture of standard-size hardwood blanks from lumber on a relatively small scale by conventional processing. Requiring an investment of just over $200,000, the conventional mill can process 500 M bf (thousand board feet) of kiln-dried lumber annually. The study focused on the economics associated with manufacture of blanks from four species -...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-17
... Products, Inc., a Division of Aleris International, Inc., Terre Haute, IN; Notice of Revised Determination... workers of Aleris Blanking and Rim Products, Inc., a division of Aleris International, Inc., Terre Haute... Blanking and Rim Products, Inc., a division of Aleris International, Inc., Terre Haute, Indiana, who became...
Mathany, Timothy M.; Land, Michael; Belitz, Kenneth
2008-01-01
Ground-water quality in the approximately 860 square-mile Coastal Los Angeles Basin study unit (CLAB) was investigated from June to November of 2006 as part of the Statewide Basin Assessment Project of the Ground-Water Ambient Monitoring and Assessment (GAMA) Program. The GAMA Statewide Basin Assessment was developed in response to the Ground-Water Quality Monitoring Act of 2001, and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The Coastal Los Angeles Basin study was designed to provide a spatially unbiased assessment of raw ground-water quality within CLAB, as well as a statistically consistent basis for comparing water quality throughout California. Samples were collected from 69 wells in Los Angeles and Orange Counties. Fifty-five of the wells were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study area (?grid wells?). Fourteen additional wells were selected to evaluate changes in ground-water chemistry or to gain a greater understanding of the ground-water quality within a specific portion of the Coastal Los Angeles Basin study unit ('understanding wells'). Ground-water samples were analyzed for: a large number of synthetic organic constituents [volatile organic compounds (VOCs), gasoline oxygenates and their degradates, pesticides, polar pesticides, and pesticide degradates, pharmaceutical compounds, and potential wastewater-indicators]; constituents of special interest [perchlorate, N-nitrosodimethylamine (NDMA), 1,4-dioxane, and 1,2,3-trichloropropane (1,2,3-TCP)]; inorganic constituents that can occur naturally [nutrients, major and minor ions, and trace elements]; radioactive constituents [gross-alpha and gross-beta radiation, radium isotopes, and radon-222]; and microbial indicators. Naturally occurring isotopes [stable isotopic ratios of hydrogen and oxygen, and activities of tritium and carbon-14] and dissolved noble gases also were measured to help identify the sources and ages of the sampled ground water. Quality-control samples (blanks, replicates, and samples for matrix spikes) were collected at approximately one-fourth of the wells, and the results for these samples were used to evaluate the quality of the data for the ground-water samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that contamination was not a significant source of bias. Differences between replicate samples were within acceptable ranges, indicating acceptably low variability. Matrix spike recoveries were within acceptable ranges for most compounds. Assessment of the quality-control information resulted in applying ?V? codes to approximately 0.1 percent of the data collected for ground-water samples (meaning a constituent was detected in blanks as well as the corresponding environmental data). This study did not attempt to evaluate the quality of drinking water delivered to consumers; after withdrawal from the ground, water typically is treated, disinfected, and (or) blended with other waters to maintain acceptable drinking-water quality. Regulatory thresholds are applied to the treated drinking water that is served to the consumer, not to raw ground water. However, to provide some context for the results, concentrations of constituents measured in the raw ground water were compared with regulatory and non-regulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA), California Department of Public Health (CDPH, formerly California Department of Health Services [CADHS]) and thresholds established for aesthetic concerns (secondary maximum contaminant levels, SMCL-CA) by CDPH. Comparisons between data collected for this study and drinking-water thresholds are for illustrative purposes only, and are not indicative of compliance or non-compliance with those thresholds. VOCs were detected in alm
NASA Astrophysics Data System (ADS)
Aretxaga, I.; Wilson, G. W.; Aguilar, E.; Alberts, S.; Scott, K. S.; Scoville, N.; Yun, M. S.; Austermann, J.; Downes, T. P.; Ezawa, H.; Hatsukade, B.; Hughes, D. H.; Kawabe, R.; Kohno, K.; Oshima, T.; Perera, T. A.; Tamura, Y.; Zeballos, M.
2011-08-01
We present a 0.72 deg2 contiguous 1.1-mm survey in the central area of the Cosmological Evolution Survey field carried out to a 1σ≈ 1.26 mJy beam-1 depth with the AzTEC camera mounted on the 10-m Atacama Submillimeter Telescope Experiment. We have uncovered 189 candidate sources at a signal-to-noise ratio (S/N) ≥ 3.5, out of which 129, with S/N ≥ 4, can be considered to have little chance of being spurious (≲2 per cent). We present the number counts derived with this survey, which show a significant excess of sources when compared to the number counts derived from the ˜0.5 deg2 area sampled at similar depths in the Submillimetre Common-User Bolometer Array (SCUBA) HAlf Degree Extragalactic Survey (SHADES). They are, however, consistent with those derived from fields that were considered too small to characterize the overall blank-field population. We identify differences to be more significant in the S1.1mm≳ 5 mJy regime, and demonstrate that these excesses in number counts are related to the areas where galaxies at redshifts z≲ 1.1 are more densely clustered. The positions of optical-infrared galaxies in the redshift interval 0.6 ≲z≲ 0.75 are the ones that show the strongest correlation with the positions of the 1.1-mm bright population (S1.1mm≳ 5 mJy), a result which does not depend exclusively on the presence of rich clusters within the survey sampled area. The most likely explanation for the observed excess in number counts at 1.1-mm is galaxy-galaxy and galaxy-group lensing at moderate amplification levels, which increases in amplitude as one samples larger and larger flux densities. This effect should also be detectable in other high-redshift populations.
[Protection and bidirectional effect of rhubarb anthraquinone and tannins for rats' liver].
Qin, Lu-shan; Zhao, Hai-ping; Zhao, Yan-ling; Ma, Zhi-jiel; Zeng, Ling-na; Zhang, Ya-ming; Zhang, Ping; Yan, Dan; Bai, Zhao-fang; Li, Yue; Hao, Qing-xiu; Zhao, Kui-jun; Wang, Jia-bo; Xiao, Xiao-he
2014-06-01
To compare the bidirectional effect of rhubarb total anthraquinone (TA) and total tannins (TT) on rats' liver. One hundred rats were randomly divided into 10 groups, i.e., the blank group, the model group, the blank + high dose TA group, the blank +low dose TA group, the blank + high dose TT group, the blank + low dose TT group, the model + high dose TA group, the model + low dose TA group, the model +high dose TT group, and the model + low dose TT group, 10 in each group. The carbon tetrachloride (CCI4) was used to prepare the acute liver injury rat model. TA and TT of rhubarb (at 5.40 g crude drugs/kg and 14.69 g crude drugs/kg) were intragastrically administrated to rats in all groups except the blank group and the model group, once daily for 6 successive days.The general state of rats, biochemical indices such as alanine aminotransferase (ALT), aspartate aminotransferase (AST), alkaline phosphatase (ALP), laminin (LN), hyaluronic acid (HA), transforming growth factor beta1 (TGF-beta1), as well pathological results of rat liver tissues. Finally the protection laws of TA and TT for rats' liver were analyzed using factor analysis. Compared with the blank control group, all biochemical indices increased in the blank group (P < 0.05, P < 0.01). HA also increased in the blank + high dose TA group; AST, ALT, and HA also increased in the blank +high dose TT group (P < 0.05). Compared with the model group, AST, ALT, ALP, HA, and TGF-beta1 significantly decreased in the model + low dose TA group, the model + high dose TA group, the model + low dose TT group (P < 0.05, P < 0.01). Serum AST, ALT, and ALP also decreased in the model + high dose TT group (P < 0.05, P < 0.01). Pathological results showed that mild swollen liver cells in the model + high dose TA group. Fatty degeneration and fragmental necrosis around the central veins occurred in the blank + high dose TA group. The pathological injury was inproved in the model +low dose TA group. Two common factors, liver fibrosis and liver cell injury, were extracted by using factor analysis. TA showed stronger improvement of the two common factors than TT. Rhubarb TA and TT showed protective and harmful effects on rats' liver. At an equivalent dosage, TA had better liver protection than TT. High dose TT played a role in liver injury to some extent.
NASA Astrophysics Data System (ADS)
Ryan, D. P.; Roth, G. S.
1982-04-01
Complete documentation of the 15 programs and 11 data files of the EPA Atomic Absorption Instrument Automation System is presented. The system incorporates the following major features: (1) multipoint calibration using first, second, or third degree regression or linear interpolation, (2) timely quality control assessments for spiked samples, duplicates, laboratory control standards, reagent blanks, and instrument check standards, (3) reagent blank subtraction, and (4) plotting of calibration curves and raw data peaks. The programs of this system are written in Data General Extended BASIC, Revision 4.3, as enhanced for multi-user, real-time data acquisition. They run in a Data General Nova 840 minicomputer under the operating system RDOS, Revision 6.2. There is a functional description, a symbol definitions table, a functional flowchart, a program listing, and a symbol cross reference table for each program. The structure of every data file is also detailed.
Stiffness management of sheet metal parts using laser metal deposition
NASA Astrophysics Data System (ADS)
Bambach, Markus; Sviridov, Alexander; Weisheit, Andreas
2017-10-01
Tailored blanks are established solutions for the production of load-adapted sheet metal components. In the course of the individualization of production, such semi-finished products are gaining importance. In addition to tailored welded blanks and tailored rolled blanks, patchwork blanks have been developed which allow a local increase in sheet thickness by welding, gluing or soldering patches onto sheet metal blanks. Patchwork blanks, however, have several limitations, on the one hand, the limited freedom of design in the production of patchwork blanks and, on the other hand, the fact that there is no optimum material bonding with the substrate. The increasing production of derivative and special vehicles on the basis of standard vehicles, prototype production and the functionalization of components require solutions with which semi-finished products and sheet metal components can be provided flexibly with local thickenings or functional elements with a firm metallurgical bond to the substrate. An alternative to tailored and patchwork blanks is, therefore, a free-form reinforcement applied by additive manufacturing via laser metal deposition (LMD). By combining metal forming and additive manufacturing, stiffness can be adapted to the loads based on standard components in a material-efficient manner and without the need to redesign the forming tools. This paper details a study of the potential of stiffness management by LMD using a demonstrator part. Sizing optimization is performed and part distortion is taken into account to find an optimal design for the cladding. A maximum stiffness increase of 167% is feasible with only 4.7% additional mass. Avoiding part distortion leads to a pareto-optimal design which achieves 95% more stiffness with 6% added mass.
Blanking and piercing theory, applications and recent experimental results
NASA Astrophysics Data System (ADS)
Zaid, Adnan l. O.
2014-06-01
Blanking and piercing are manufacturing processes by which certain geometrical shapes are sheared off a sheet metal. If the sheared off part is the one required, the processes referred to as blanking and if the remaining part in the sheet is the one required, the process is referred to as piercing. In this paper, the theory and practice of these processes are reviewed and discussed The main parameters affecting these processes are presented and discussed. These include: the radial clearance percentage, punch and die geometrical parameters, for example punch and die profile radii. The abovementioned parameters on the force and energy required to effect blanking together with their effect on the quality of the products are also presented and discussed. Recent experimental results together with photomacrographs and photomicrographs are also included and discussed. Finally, the effect of punch and die wear on the quality of the blanks is alsogiven and discussed.
Li, Xiang; Arzhantsev, Sergey; Kauffman, John F; Spencer, John A
2011-04-05
Four portable NIR instruments from the same manufacturer that were nominally identical were programmed with a PLS model for the detection of diethylene glycol (DEG) contamination in propylene glycol (PG)-water mixtures. The model was developed on one spectrometer and used on other units after a calibration transfer procedure that used piecewise direct standardization. Although quantitative results were produced, in practice the instrument interface was programmed to report in Pass/Fail mode. The Pass/Fail determinations were made within 10s and were based on a threshold that passed a blank sample with 95% confidence. The detection limit was then established as the concentration at which a sample would fail with 95% confidence. For a 1% DEG threshold one false negative (Type II) and eight false positive (Type I) errors were found in over 500 samples measured. A representative test set produced standard errors of less than 2%. Since the range of diethylene glycol for economically motivated adulteration (EMA) is expected to be above 1%, the sensitivity of field calibrated portable NIR instruments is sufficient to rapidly screen out potentially problematic materials. Following method development, the instruments were shipped to different sites around the country for a collaborative study with a fixed protocol to be carried out by different analysts. NIR spectra of replicate sets of calibration transfer, system suitability and test samples were all processed with the same chemometric model on multiple instruments to determine the overall analytical precision of the method. The combined results collected for all participants were statistically analyzed to determine a limit of detection (2.0% DEG) and limit of quantitation (6.5%) that can be expected for a method distributed to multiple field laboratories. Published by Elsevier B.V.
Validation of a standardized extraction method for formalin-fixed paraffin-embedded tissue samples.
Lagheden, Camilla; Eklund, Carina; Kleppe, Sara Nordqvist; Unger, Elizabeth R; Dillner, Joakim; Sundström, Karin
2016-07-01
Formalin-fixed paraffin-embedded (FFPE) samples can be DNA-extracted and used for human papillomavirus (HPV) genotyping. The xylene-based gold standard for extracting FFPE samples is laborious, suboptimal and involves health hazards for the personnel involved. To compare extraction with the standard xylene method to a xylene-free method used in an HPV LabNet Global Reference Laboratory at the Centers for Disease Control (CDC); based on a commercial method with an extra heating step. Fifty FFPE samples were randomly selected from a national audit of all cervical cancer cases diagnosed in Sweden during 10 years. For each case-block, a blank-block was sectioned, as a control for contamination. For xylene extraction, the standard WHO Laboratory Manual protocol was used. For the CDC method, the manufacturers' protocol was followed except for an extra heating step, 120°C for 20min. Samples were extracted and tested in parallel with β-globin real-time PCR, HPV16 real-time PCR and HPV typing using modified general primers (MGP)-PCR and Luminex assays. For a valid result the blank-block had to be betaglobin-negative in all tests and the case-block positive for beta-globin. Overall, detection was improved with the heating method and the amount of HPV-positive samples increased from 70% to 86% (p=0.039). For all samples where HPV type concordance could be evaluated, there was 100% type concordance. A xylene-free and robust extraction method for HPV-DNA typing in FFPE material is currently in great demand. Our proposed standardized protocol appears to be generally useful. Copyright © 2016. Published by Elsevier B.V.
Automatic classification of blank substrate defects
NASA Astrophysics Data System (ADS)
Boettiger, Tom; Buck, Peter; Paninjath, Sankaranarayanan; Pereira, Mark; Ronald, Rob; Rost, Dan; Samir, Bhamidipati
2014-10-01
Mask preparation stages are crucial in mask manufacturing, since this mask is to later act as a template for considerable number of dies on wafer. Defects on the initial blank substrate, and subsequent cleaned and coated substrates, can have a profound impact on the usability of the finished mask. This emphasizes the need for early and accurate identification of blank substrate defects and the risk they pose to the patterned reticle. While Automatic Defect Classification (ADC) is a well-developed technology for inspection and analysis of defects on patterned wafers and masks in the semiconductors industry, ADC for mask blanks is still in the early stages of adoption and development. Calibre ADC is a powerful analysis tool for fast, accurate, consistent and automatic classification of defects on mask blanks. Accurate, automated classification of mask blanks leads to better usability of blanks by enabling defect avoidance technologies during mask writing. Detailed information on blank defects can help to select appropriate job-decks to be written on the mask by defect avoidance tools [1][4][5]. Smart algorithms separate critical defects from the potentially large number of non-critical defects or false defects detected at various stages during mask blank preparation. Mechanisms used by Calibre ADC to identify and characterize defects include defect location and size, signal polarity (dark, bright) in both transmitted and reflected review images, distinguishing defect signals from background noise in defect images. The Calibre ADC engine then uses a decision tree to translate this information into a defect classification code. Using this automated process improves classification accuracy, repeatability and speed, while avoiding the subjectivity of human judgment compared to the alternative of manual defect classification by trained personnel [2]. This paper focuses on the results from the evaluation of Automatic Defect Classification (ADC) product at MP Mask Technology Center (MPMask). The Calibre ADC tool was qualified on production mask blanks against the manual classification. The classification accuracy of ADC is greater than 95% for critical defects with an overall accuracy of 90%. The sensitivity to weak defect signals and locating the defect in the images is a challenge we are resolving. The performance of the tool has been demonstrated on multiple mask types and is ready for deployment in full volume mask manufacturing production flow. Implementation of Calibre ADC is estimated to reduce the misclassification of critical defects by 60-80%.
Radiochemical determination of 237NP in soil samples contaminated with weapon grade plutonium
NASA Astrophysics Data System (ADS)
Antón, M. P.; Espinosa, A.; Aragón, A.
2006-01-01
The Palomares terrestrial ecosystem (Spain) constitutes a natural laboratory to study transuranics. This scenario is partially contaminated with weapon-grade plutonium since the burnout and fragmentation of two thermonuclear bombs accidentally dropped in 1966. While performing radiometric measurements in the field, the possible presence of 237Np was observed through its 29 keV gamma emission. To accomplish a detailed characterization of the source term in the contaminated area using the isotopic ratios Pu-Am-Np, the radiochemical isolation and quantification by alpha spectrometry of 237Np was initiated. The selected radiochemical procedure involves separation of Np from Am, U and Pu with ionic resins, given that in soil samples from Palomares 239+240Pu levels are several orders of magnitude higher than 237Np. Then neptunium is isolated using TEVA organic resins. After electrodeposition, quantification is performed by alpha spectrometry. Different tests were done with blank solutions spiked with 236Pu and 237Np, solutions resulting from the total dissolution of radioactive particles and soil samples. Results indicate that the optimal sequential radionuclide separation order is Pu-Np, with decontamination percentages obtained with the ionic resins ranging from 98% to 100%. Also, the addition of NaNO2 has proved to be necessary, acting as a stabilizer of Pu-Np valences.
Herrington, Jason S
2013-08-20
The costly damage airborne trimethylsilanol (TMS) exacts on optics in the semiconductor industry has resulted in the demand for accurate and reliable methods for measuring TMS at trace levels (i.e., parts per trillion, volume per volume of air [ppt(v)] [~ng/m(3)]). In this study I developed a whole air canister-based approach for field sampling trimethylsilanol in air, as well as a preconcentration gas chromatography/mass spectrometry laboratory method for analysis. The results demonstrate clean canister blanks (0.06 ppt(v) [0.24 ng/m(3)], which is below the detection limit), excellent linearity (a calibration relative response factor relative standard deviation [RSD] of 9.8%) over a wide dynamic mass range (1-100 ppt(v)), recovery/accuracy of 93%, a low selected ion monitoring method detection limit of 0.12 ppt(v) (0.48 ng/m(3)), replicate precision of 6.8% RSD, and stability (84% recovery) out to four days of storage at room temperature. Samples collected at two silicon wafer fabrication facilities ranged from 10.0 to 9120 ppt(v) TMS and appear to be associated with the use of hexamethyldisilazane priming agent. This method will enable semiconductor cleanroom managers to monitor and control for trace levels of trimethylsilanol.
1987-01-01
due to interferences in the pollen. However, the identity of the interferents is presently unknown. A dried papaya leaf was treated with 10 ml of warm...Known amounts of DON, DAS, and T-2 were spiked on a blank (trichothecene-free) papaya leaf and left exposed in a bottle for 1 year. At the end of the year...Simple Trichothecenes from Leaf Sample after Prolonged Exposure ............... 35 12 Sample Analysis .............................. .... 37 6 MASS
Biswal, Avijit; Minakshi, Manickam; Tripathy, Bankim Chandra
2016-04-07
In the present work, a novel biopolymer approach has been made to electrodeposit manganese dioxide from manganese sulphate in a sulphuric acid bath containing chitosan in the absence and presence of glutaraldehyde as a cross-linking agent. Galvanostatically synthesised electrolytic manganese dioxide (EMD) nanoflakes were used as electrode materials and their electrochemical properties with the influence of biopolymer chitosan were systematically characterized. The structural determination, surface morphology and porosity of nanostructured EMD were evaluated using X-ray diffraction, Fourier transform infrared spectroscopy, field emission scanning electron microscopy and nitrogen adsorption-desorption techniques. The results obtained were compared with that of blank EMD (polymer free). The results indicated that the EMD having chitosan cross-linked with glutaraldehyde possesses a reduced particle size and more porous structure than the blank and EMDs synthesized in the presence of chitosan but without glutaraldehyde. The results revealed that chitosan was unable to play any significant role on its own but chitosan in the presence of glutaraldehyde forms a cross-linking structure, which in turn influences the nucleation and growth of the EMDs during electrodeposition. EMDs obtained in the presence of chitosan (1 g dm(-3)) and glutaraldehyde (1% glutaraldehyde) exhibited a reversible and better discharge capacity upon cycling than the blank which showed its typical capacity fading behaviour with cycling. In addition, EMD synthesized in the presence of 1 g dm(-3) chitosan and 2% glutaraldehyde exhibited a superior electrochemical performance than the blank and lower amounts (1%; 1.5%) of glutaraldehyde, showing a stable discharge capacity of 60 mA h g(-1) recorded up to 40 cycles in alkaline KOH electrolyte for a Zn-MnO2 system. Our results demonstrate the potential of using polymer modified EMDs as a new generation of alkaline battery materials. The XPS data show that a surface functional moiety arising from the cross-linked chitosan enhances the electrochemical properties of the Zn-MnO2 system.
Mathany, Timothy M.; Kulongoski, Justin T.; Ray, Mary C.; Belitz, Kenneth
2009-01-01
Groundwater quality in the approximately 653-square-mile South Coast Interior Basins (SCI) study unit was investigated from August to December 2008, as part of the Priority Basins Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basins Project was developed in response to Legislative mandates (Supplemental Report of the 1999 Budget Act 1999-00 Fiscal Year; and, the Groundwater-Quality Monitoring Act of 2001 [Sections 10780-10782.3 of the California Water Code, Assembly Bill 599]) to assess and monitor the quality of groundwater used as public supply for municipalities in California, and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). SCI was the 27th study unit to be sampled as part of the GAMA Priority Basins Project. This study was designed to provide a spatially unbiased assessment of the quality of untreated groundwater used for public water supplies within SCI, and to facilitate statistically consistent comparisons of groundwater quality throughout California. Samples were collected from 54 wells within the three study areas [Livermore, Gilroy, and Cuyama] of SCI in Alameda, Santa Clara, San Benito, Santa Barbara, Ventura, and Kern Counties. Thirty-five of the wells were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study unit (grid wells), and 19 were selected to aid in evaluation of specific water-quality issues (understanding wells). The groundwater samples were analyzed for organic constituents [volatile organic compounds (VOCs), pesticides and pesticide degradates, polar pesticides and metabolites, and pharmaceutical compounds], constituents of special interest [perchlorate and N-nitrosodimethylamine (NDMA)], naturally occurring inorganic constituents [trace elements, nutrients, major and minor ions, silica, total dissolved solids (TDS), and alkalinity], and radioactive constituents [gross alpha and gross beta radioactivity and radon-222]. Naturally occurring isotopes [stable isotopes of hydrogen, oxygen, and carbon, and activities of tritium and carbon-14] and dissolved noble gases also were measured to help identify the sources and ages of the sampled groundwater. In total, 288 constituents and water-quality indicators (field parameters) were investigated. Three types of quality-control samples (blanks, replicates, and matrix spikes) each were collected at approximately 4-11 percent of the wells, and the results for these samples were used to evaluate the quality of the data for the groundwater samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that contamination was not a significant source of bias in the data obtained from the groundwater samples. Differences between replicate samples generally were less than 10 percent relative standard deviation, indicating acceptable analytical reproducibility. Matrix spike recoveries were within the acceptable range (70 to 130 percent) for most compounds. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, untreated groundwater typically is treated, disinfected, and/or blended with other waters to maintain water quality. Regulatory thresholds apply to water that is served to the consumer, not to untreated groundwater. However, to provide some context for the results, concentrations of constituents measured in the untreated groundwater were compared with regulatory and nonregulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and California Department of Public Health (CDPH), and to nonregulatory thresholds established for aesthetic and technical concerns by CDPH. Comparisons between data collected for this study and thresholds for drinking water are for illustrative purposes only, and are not indicative of complia
The Fall 1973 New Student Week Leaders at Southern Illinois University at Carbondale.
ERIC Educational Resources Information Center
Paciello, Antonio Joseph
This study describes a sample of college students who participated as New Student Week Leaders (NSWL). Vocational interests, as measured by the Strong Vocational Interest Blank for Men (SVIB-M), academic pursuits, campus involvement, and other factors were considered in an attempt to define a NSWL. Eighty-six items were chosen from the SVIB-M to…
ERIC Educational Resources Information Center
Terman, Lewis M., Ed.
The 35 years' followup of the Terman investigation on the gifted child is presented. In order to describe the gifted group of mid-life, a general information blank was mailed in 1950 (1,437 subjects) and in 1955 (1,424 subjects). The field study, completed in 1952, included personal interviews, the Concept Mastery Test, supplementary…
1989-03-21
Seattle.Washington 98108 (206)767-5060 Chemistr . Microbklog. and Technical Services 1. TO: Science Applications International Corporation LABORATORY I.D...Certificate 940 South HarneySt.. Seattle.Washington 98108 (206)767-5060 ) Chemistr . Micrcbiob .and Technical Services TO: Science Applications...HarnreySt Seattle.Washington 98108 (206)767-5060 Chemistr " Microbiocoy and Technical Services SAIC LABORATORY NO. 3894 APPENDIX A Method Blank
Costs and Benefits of Software Process Improvement
1997-12-01
Washington, DC 20503. 1. AGENCY USE ONLY ( Leave blank) 2. REPORT DATE December 1997 3. REPORT TYPE AND DATES COVERED Master’s Thesis 4...in this field, an organization’s chance for success depends first on having an exceptional manager and an effective development team (PEOPLE...Secondly, it depends on its effective use of TECHNOLOGY, and finally, on its PROCESS maturity. [Ref. 4] In a software organization: PEOPLE refers to
Super-Radiant Free Electron Laser Measurement and Detection
2013-09-01
collection of information is estimated to average 1 hour per response, including the time for reviewing instruction, searching existing data sources... relativistic electron bunches and a periodic magnetic field to generate coherent radiation. These types of lasers are of interest to the Navy because...Physics iv THIS PAGE INTENTIONALLY LEFT BLANK v ABSTRACT A free electron laser (FEL) is a type of laser that use relativistic electron bunches
High-speed blanking of copper alloy sheets: Material modeling and simulation
NASA Astrophysics Data System (ADS)
Husson, Ch.; Ahzi, S.; Daridon, L.
2006-08-01
To optimize the blanking process of thin copper sheets ( ≈ 1. mm thickness), it is necessary to study the influence of the process parameters such as the punch-die clearance and the wear of the punch and the die. For high stroke rates, the strain rate developed in the work-piece can be very high. Therefore, the material modeling must include the dynamic effects.For the modeling part, we propose an elastic-viscoplastic material model combined with a non-linear isotropic damage evolution law based on the theory of the continuum damage mechanics. Our proposed modeling is valid for a wide range of strain rates and temperatures. Finite Element simulations, using the commercial code ABAQUS/Explicit, of the blanking process are then conducted and the results are compared to the experimental investigations. The predicted cut edge of the blanked part and the punch-force displacement curves are discussed as function of the process parameters. The evolution of the shape errors (roll-over depth, fracture depth, shearing depth, and burr formation) as function of the punch-die clearance, the punch and the die wear, and the contact punch/die/blank-holder are presented. A discussion on the different stages of the blanking process as function of the processing parameters is given. The predicted results of the blanking dependence on strain-rate and temperature using our modeling are presented (for the plasticity and damage). The comparison our model results with the experimental ones shows a good agreement.
So, M K; Taniyasu, S; Lam, P K S; Zheng, G J; Giesy, J P; Yamashita, N
2006-02-01
Perfluorinated compounds (PFCs), such as perfluorooctane sulfonate (PFOS), have been identified in the coastal waters of China and Japan. An alkaline digestion method, coupled with solid-phase extraction (SPE), and high-performance liquid chromatography interfaced with high-resolution electrospray tandem mass spectrometry was developed to determine PFCs in mussel and oyster samples from coastal waters of South China and Japan. These techniques produced adequate recoveries and reporting limits with small quantities of PFCs. Concentrations of individual PFCs in mussels and oysters from South China and Japan ranged from 113.6 to 586.0 pg/g, wet weight (ww) for PFOS, 63.1 to 511.6 pg/g, ww for perfluorohexane sulfonate, 9.3 to 30.1 pg/g, ww for perfluorobutane sulfonate and 37.8 to 2957.0 pg/g, ww for perfluorooctane sulfonamide. The quantification of perfluorinated carboxylates was compromised by interferences from carboxylates in the procedural blanks. Perfluoroundecanoate and perfluorononanoate had relatively great blank interferences, which resulted in relatively poor limits of quantification for these compounds. Some PFCs were only identified in a limited number of samples: perfluorododecanoate in samples from Tokyo Bay, Japan (195.9 pg/g, ww); and perfluorodecanoate in Fuzhou, China (131.7 pg/g, ww) and Tokyo Bay (118.6 pg/g, ww). The greatest concentrations of perfluorooctanoate, perfluoroheptanoate, and perfluorohexanoate were observed in samples from Tokyo Bay and Bei Hai, South China.
NASA Astrophysics Data System (ADS)
Lhomé, Emilie; Agócs, Tibor; Abrams, Don Carlos; Dee, Kevin M.; Middleton, Kevin F.; Tosh, Ian A.; Jaskó, Attila; Connor, Peter; Cochrane, Dave; Gers, Luke; Jonas, Graeme; Rakich, Andrew; Benn, Chris R.; Balcells, Marc; Trager, Scott C.; Dalton, Gavin B.; Carrasco, Esperanza; Vallenari, Antonella; Bonifacio, Piercarlo; Aguerri, J. Alfonso L.
2016-07-01
In this paper, we detail the manufacturing process for the lenses that will constitute the new two-degree field-of-view Prime Focus Corrector (PFC) for the 4.2m William Herschel Telescope (WHT) optimised for the upcoming WEAVE Multi-Object Spectroscopy (MOS) facility. The corrector, including an Atmospheric Dispersion Corrector (ADC), is made of six large lenses, the largest being 1.1-meter diameter. We describe how the prescriptions of the optical design were translated into manufacturing specifications for the blanks and lenses. We explain how the as-built glass blank parameters were fed back into the optical design and how the specifications for the lenses were subsequently modified. We review the critical issues for the challenging manufacturing process and discuss the trade-offs that were necessary to deliver the lenses while maintaining the optimal optical performance. A short description of the lens optical testing is also presented. Finally, the subsequent manufacturing steps, including assembly, integration, and alignment are outlined.
Repair of localized defects in multilayer-coated reticle blanks for extreme ultraviolet lithography
Stearns, Daniel G [Los Altos, CA; Sweeney, Donald W [San Ramon, CA; Mirkarimi, Paul B [Sunol, CA
2004-11-23
A method is provided for repairing defects in a multilayer coating layered onto a reticle blank used in an extreme ultraviolet lithography (EUVL) system. Using high lateral spatial resolution, energy is deposited in the multilayer coating in the vicinity of the defect. This can be accomplished using a focused electron beam, focused ion beam or a focused electromagnetic radiation. The absorbed energy will cause a structural modification of the film, producing a localized change in the film thickness. The change in film thickness can be controlled with sub-nanometer accuracy by adjusting the energy dose. The lateral spatial resolution of the thickness modification is controlled by the localization of the energy deposition. The film thickness is adjusted locally to correct the perturbation of the reflected field. For example, when the structural modification is a localized film contraction, the repair of a defect consists of flattening a mound or spreading out the sides of a depression.
2012-09-01
Thesis Advisor: Robert Springborg Second Reader: Mohammed M. Hafez THIS PAGE INTENTIONALLY LEFT BLANK i REPORT DOCUMENTATION PAGE Form...of secular subjects. vi THIS PAGE INTENTIONALLY LEFT BLANK vii TABLE OF CONTENTS I . INTRODUCTION...understanding, this thesis would not have been possible. xii THIS PAGE INTENTIONALLY LEFT BLANK 1 I . INTRODUCTION A. MAJOR RESEARCH QUESTION The
Exploring Valued-Added Options - Edge-Glued Panels and Blanks Offer Value-Added Opportunities
Bob Smith; Philip A. Araman
1997-01-01
As sawmills search for new opportunities to add value to rough sawn lumber, many consider producing dimension parts as one solution. Assembling dimension parts into edge-glued panels or standard blanks can add even further value. Blanks are defined as pieces of solid wood (which may be edge-glued) that are manufactured to a predetermined size. This article discusses...
A gunner model for an AAA tracking task with interrupted observations
NASA Technical Reports Server (NTRS)
Yu, C. F.; Wei, K. C.; Vikmanis, M.
1982-01-01
The problem of modeling a trained human operator's tracking performance in an anti-aircraft system under various display blanking conditions is discussed. The input to the gunner is the observable tracking error subjected to repeated interruptions (blanking). A simple and effective gunner model was developed. The effect of blanking on the gunner's tracking performance is approached via modeling the observer and controller gains.
Penetrating ocular trauma associated with blank cartridge
2014-01-01
Background Blank cartridge guns are generally regarded as being harmless and relative safe. However recent published articles demonstrated that the gas pressure from the exploding propellant of blank cartridge is powerful enough to penetrate the thoracic wall, abdominal muscle, small intestine and the skull. And there has been a limited number of case reports of ocular trauma associated with blank cartridge injury. In addition, no report on case with split extraocular muscle injury with traumatic cataract and penetrating corneoscleral wound associated with blank cartridge has been previously documented. This report describes the case of patient who sustained penetrating ocular injury with extraocular muscle injury by a close-distance blank cartridge that required surgical intervention. Case presentation A 20-year-old man sustained a penetrating globe injury in the right eye while cleaning a blank cartridge pistol. His uncorrected visual acuity at presentation was hand motion and he had a flame burn of his right upper and lower lid with multiple missile wounds. On slit-lamp examination, there was a 12-mm laceration of conjunctiva along the 9 o'clock position with two pinhole-like penetrating injuries of cornea and sclera. There was also a 3-mm corneal laceration between 9 o'clock and 12 o'clock and the exposed lateral rectus muscle was split. Severe Descemet's membrane folding with stromal edema was observed, and numerous yellow, powder-like foreign bodies were impacted in the cornea. Layered anterior chamber bleeding with traumatic cataract was also noted. Transverse view of ultrasonography showed hyperechoic foreign bodies with mild reduplication echoes and shadowing. However, a computed tomographic scan using thin section did not reveal a radiopaque foreign body within the right globe. Conclusion To our best knowledge, this is the first case report of split extraocular muscle injury with traumatic cataract and penetrating ocular injury caused by blank cartridge injury. Intraocular foreign bodies undetectable by CT were identified by B-scan ultrasonography in our patient. This case highlights the importance of additional ultrasonography when evaluating severe ocular trauma. And ophthalmologists should consider the possibility of penetrating injury caused by blank ammunition. PMID:24589340
Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.
2006-01-01
The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance and quality-control data were stored in the laboratory's LabMaster data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality-control samples analyzed from July 1999 through June 2001. Results for the quality-control samples for 18 analytical procedures were evaluated for bias and precision. Control charts indicate that data for eight of the analytical procedures were occasionally biased for either high-concentration or low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, total monomeric aluminum, total aluminum, calcium, chloride and nitrate (ion chromatography and colormetric method) and sulfate. The total aluminum and dissolved organic carbon procedures were biased throughout the analysis period for the high-concentration sample, but were within control limits. The calcium and specific conductance procedures were biased throughout the analysis period for the low-concentration sample, but were within control limits. The magnesium procedure was biased for the high-concentration and low concentration samples, but was within control limits. Results from the filter-blank and analytical-blank analyses indicate that the procedures for 14 of 15 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. The data-quality objective was not met for dissolved organic carbon. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 17 of the 18 analytes. At least 90 percent of the samples met data-quality objectives for all analytes except ammonium (81 percent of samples met objectives), chloride (75 percent of samples met objectives), and sodium (86 percent of samples met objectives). Results of the USGS interlaboratory Standard Reference Sample (SRS) Project indicated good data quality over the time period, with most ratings for each sample in the good to excellent range. The P-sample (low-ionic-strength constituents) analysis had one satisfactory rating for the specific conductance procedure in one study. The T-sample (trace constituents) analysis had one satisfactory rating for the aluminum procedure in one study and one unsatisfactory rating for the sodium procedure in another. The remainder of the samples had good or excellent ratings for each study. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 89 percent of the samples met data-quality objectives for 10 of the 14 analytes; the exceptions were ammonium, total aluminum, dissolved organic carbon, and sodium. Results indicate a positive bias for the ammonium procedure in all studies. Data-quality objectives were not met in 50 percent of samples analyzed for total aluminum, 38 percent of samples analyzed for dissolved organic carbon, and 27 percent of samples analyzed for sodium. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 91 percent of the samples analyzed for calcium, chloride, fluoride, magnesium, pH, potassium, and sulfate. Data-quality objectives were met by 75 percent of the samples analyzed for sodium and 58 percent of the samples analyzed for specific conductance.
Formation mechanism of the photomask blanks material related haze
NASA Astrophysics Data System (ADS)
Kim, Jung-Jin; Choi, Junyoul; Koh, Soowan; Kim, Minho; Lee, Jiyoung; Lee, Han-Shin; Kim, Byung Gook; Jeon, Chan-uk
2016-05-01
We have observed a new type haze of which formation deviates from the generally accepted models with respect to the size, shape, and removability by chemicals. It has very small size of 50~100nm and are crowded around the cell boundary, while the typical haze doesn't prefer a special region on mask in the majority of cases. It is hard to remove by general cleaning, while the typical haze is easily removed by general cleaning process and even de-ionized water. It is confirmed that the source of the haze is blank material related ions which are formed by chemical etching of blanks during mask cleaning process or the photomask blanks itself.
Near-field visual acuity of pigeons: effects of head location and stimulus luminance.
Hodos, W; Leibowitz, R W; Bonbright, J C
1976-03-01
Two pigeons were trained to discriminate a grating stimulus from a blank stimulus of equivalent luminance in a three-key chamber. The stimuli and blanks were presented behind a transparent center key. The procedure was a conditional discrimination in which pecks on the left key were reinforced if the blank had been present behind the center key and pecks on the right key were reinforced if the grating had been present behind the center key. The spatial frequency of the stimuli was varied in each session from four to 29.5 lines per millimeter in accordance with a variation of the method of constant stimuli. The number of lines per millimeter that the subjects could discriminate at threshold was determined from psychometric functions. Data were collected at five values of stimulus luminance ranging from--0.07 to 3.29 log cd/m2. The distance from the stimulus to the anterior nodal point of the eye, which was determined from measurements taken from high-speed motion-picture photographs of three additional pigeons and published intraocular measurements, was 62.0 mm. This distance and the grating detection thresholds were used to calculate the visual acuity of the birds at each level of luminance. Acuity improved with increasing luminance to a peak value of 0.52, which corresponds to a visual angle of 1.92 min, at a luminance of 2.33 log cd/m2. Further increase in luminance produced a small decline in acuity.
NASA Astrophysics Data System (ADS)
Stengel, Martin; Stapelberg, Stefan; Sus, Oliver; Schlundt, Cornelia; Poulsen, Caroline; Thomas, Gareth; Christensen, Matthew; Carbajal Henken, Cintia; Preusker, Rene; Fischer, Jürgen; Devasthale, Abhay; Willén, Ulrika; Karlsson, Karl-Göran; McGarragh, Gregory R.; Proud, Simon; Povey, Adam C.; Grainger, Roy G.; Fokke Meirink, Jan; Feofilov, Artem; Bennartz, Ralf; Bojanowski, Jedrzej S.; Hollmann, Rainer
2017-11-01
New cloud property datasets based on measurements from the passive imaging satellite sensors AVHRR, MODIS, ATSR2, AATSR and MERIS are presented. Two retrieval systems were developed that include components for cloud detection and cloud typing followed by cloud property retrievals based on the optimal estimation (OE) technique. The OE-based retrievals are applied to simultaneously retrieve cloud-top pressure, cloud particle effective radius and cloud optical thickness using measurements at visible, near-infrared and thermal infrared wavelengths, which ensures spectral consistency. The retrieved cloud properties are further processed to derive cloud-top height, cloud-top temperature, cloud liquid water path, cloud ice water path and spectral cloud albedo. The Cloud_cci products are pixel-based retrievals, daily composites of those on a global equal-angle latitude-longitude grid, and monthly cloud properties such as averages, standard deviations and histograms, also on a global grid. All products include rigorous propagation of the retrieval and sampling uncertainties. Grouping the orbital properties of the sensor families, six datasets have been defined, which are named AVHRR-AM, AVHRR-PM, MODIS-Terra, MODIS-Aqua, ATSR2-AATSR and MERIS+AATSR, each comprising a specific subset of all available sensors. The individual characteristics of the datasets are presented together with a summary of the retrieval systems and measurement records on which the dataset generation were based. Example validation results are given, based on comparisons to well-established reference observations, which demonstrate the good quality of the data. In particular the ensured spectral consistency and the rigorous uncertainty propagation through all processing levels can be considered as new features of the Cloud_cci datasets compared to existing datasets. In addition, the consistency among the individual datasets allows for a potential combination of them as well as facilitates studies on the impact of temporal sampling and spatial resolution on cloud climatologies.
For each dataset a digital object identifier has been issued:
Cloud_cci AVHRR-AM: https://doi.org/10.5676/DWD/ESA_Cloud_cci/AVHRR-AM/V002
Cloud_cci AVHRR-PM: https://doi.org/10.5676/DWD/ESA_Cloud_cci/AVHRR-PM/V002
Cloud_cci MODIS-Terra: https://doi.org/10.5676/DWD/ESA_Cloud_cci/MODIS-Terra/V002
Cloud_cci MODIS-Aqua: https://doi.org/10.5676/DWD/ESA_Cloud_cci/MODIS-Aqua/V002
Cloud_cci ATSR2-AATSR: https://doi.org/10.5676/DWD/ESA_Cloud_cci/ATSR2-AATSR/V002
Cloud_cci MERIS+AATSR: https://doi.org/10.5676/DWD/ESA_Cloud_cci/MERIS+AATSR/V002
NASA Astrophysics Data System (ADS)
Tan, C. J.; Aslian, A.; Honarvar, B.; Puborlaksono, J.; Yau, Y. H.; Chong, W. T.
2015-12-01
We constructed an FE axisymmetric model to simulate the effect of partially hardened blanks on increasing the limiting drawing ratio (LDR) of cylindrical cups. We partitioned an arc-shaped hard layer into the cross section of a DP590 blank. We assumed the mechanical property of the layer is equivalent to either DP980 or DP780. We verified the accuracy of the model by comparing the calculated LDR for DP590 with the one reported in the literature. The LDR for the partially hardened blank increased from 2.11 to 2.50 with a 1 mm depth of DP980 ring-shaped hard layer on the top surface of the blank. The position of the layer changed with drawing ratios. We proposed equations for estimating the inner and outer diameters of the layer, and tested its accuracy in the simulation. Although the outer diameters fitted in well with the estimated line, the inner diameters are slightly less than the estimated ones.
NASA Astrophysics Data System (ADS)
Hull, Tony; Westerhoff, Thomas
2014-10-01
While there is no single material solution ideal for all missions, recent advances by SCHOTT in fabricating lightweight mirror blanks makes ZERODUR® a highly viable solution for many spaceborne telescopes. ZERODUR® is a well-characterized very low-expansion material. Monolithic mirrors are made without bonding or fusing out of highly homogeneous and isotropic blanks currently available in sizes up to 4m plus. We will summarize results recently given in a series of papers on the characteristics of these lightweight mirror blanks in sizes from 0.3m up, and describe the method of blank fabrication, with its compatibility to contemporary optical fabrication techniques that control of all optical spatial frequencies. ZERODUR® has a 35 year heritage in space on numerous missions, including the secondary mirror of Hubble, and all the Chandra mirrors. With the lightweighting we will discuss, ZERODUR® is now a high performing, affordable and rapidly produced mirror substrate suitable for lightweight imaging telescopes.
Laboratory Noble Gas Migration Experiments through Rock
NASA Astrophysics Data System (ADS)
Broome, S.; Cashion, A.; Feldman, J.; Sussman, A. J.; Swanson, E.; Wilson, J.
2016-12-01
The Underground Nuclear Explosion Signatures Experiment (UNESE) was created to address science and research and development aspects associated with nuclear explosion verification and nuclear nonproliferation with a focus on non-prompt signals. A critical component of the UNESE program is a realistic understanding of the post-detonation processes and changes in the environment that produce observable physical and radio-chemical signatures. As such, an understanding of noble gas migration properties through various lithologies is essential. Here we present an empirical methodology to measure tortuosity on well-characterized rhyolitic tuffs and lavas. Tortuosity is then compared with microfracture networks characterized by microscopy. To quantify tortuosity, a pressurized (1500 mbar) fixed volume of argon is expanded into a sample under high vacuum (0.200 mbar). A quadrupole mass spectrometer (QMS) is used to measure argon downstream of the sample in real time, allowing the time-series gas arrival curve to be characterized for each sample. To evaluate the method, blank samples have been machined to correspond with tortuosities of 1, 2, and 4 in conjunction with a restricted-flow valve to mimic rock sample permeability. Data from the blanks are analyzed with this system to correct for system effects on gas arrival. High vacuum is maintained in the QMS system during sampling by precise metering of the gas through a leak valve with active feedback control which allows arrival time and concentration of argon to be established in real time. Along with a comprehensive characterization of the rock and fracture properties, the parameters derived from these experiments will provide invaluable insight into the three-dimensional structure of damage zones, the production of temporally variable signatures and the methods to best detect underground nuclear explosion signatures. SAND2016-7309 A
Williams, Shannon D.; Farmer, James
2003-01-01
The U.S. Geological Survey (USGS), in cooperation with the Tennessee Department of Environment and Conservation, Division of Superfund, collected discharge, rainfall, continuous water-quality (temperature, dissolved oxygen, specific conductance, and pH), and volatile organic compound (VOC) data from three karst springs in Middle Tennessee from February 2000 to May 2001. Continuous monitoring data indicated that each spring responds differently to storms. Water quality and discharge at Wilson Spring, which is located in the Central Basin karst region of Tennessee, changed rapidly after rainfall. Water quality and discharge also varied at Cascade Spring; however, changes did not occur as frequently or as quickly as changes at Wilson Spring. Water quality and discharge at Big Spring at Rutledge Falls changed little in response to storms. Cascade Spring and Big Spring at Rutledge Falls are located in similar hydrogeologic settings on the escarpment of the Highland Rim. Nonisokinetic dip-sampling methods were used to collect VOC samples from the springs during base-flow conditions. During selected storms, automatic samplers were used to collect water samples at Cascade Spring and Wilson Spring. Water samples were collected as frequently as every 15 minutes at the beginning of a storm, and sampling intervals were gradually increased following a storm. VOC samples were analyzed using a portable gas chromatograph (GC). VOC samples were collected from Wilson, Cascade, and Big Springs during 600, 199, and 55 sampling times, respectively, from February 2000 to May 2001. Chloroform concentrations detected at Wilson Spring ranged from 0.073 to 34 mg/L (milligrams per liter). Chloroform concentrations changed during most storms; the greatest change detected was during the first storm in fall 2000, when chloroform concentrations increased from about 0.5 to about 34 mg/L. Concentrations of cis-1,2-dichloroethylene (cis-1,2-DCE) detected at Cascade Spring ranged from 0.30 to 1.8 ?g/L (micrograms per liter) and gradually decreased between November 2000 and May 2001. In addition to the gradual decrease in cis-1,2-DCE concentrations, some additional decreases were detected during storms. VOC samples collected at weekly intervals from Big Spring indicated a gradual decrease in trichloroethylene (TCE) concentrations from approximately 9 to 6 ?g/L between November 2000 and May 2001. Significant changes in TCE concentrations were not detected during individual storms at Big Spring. Quality-control samples included trip blanks, equipment blanks, replicates, and field-matrix spike samples. VOC concentrations measured using the portable GC were similar to concentrations in replicate samples analyzed by the USGS National Water Quality Laboratory (NWQL) with the exception of chloroform and TCE concentrations. Chloroform and TCE concentrations detected by the portable GC were consistently lower (median percent differences of ?19.2 and ?17.4, respectively) than NWQL results. High correlations, however, were observed between concentrations detected by the portable GC and concentrations detected by the NWQL (Pearson?s r > 0.96). VOC concentrations in automatically collected samples were similar to concentrations in replicates collected using dip-sampling methods. More than 80 percent of the VOC concentrations measured in automatically collected samples were within 12 percent of concentrations in dip samples.
Golovashchenko, Sergey Fedorovich [Beverly Hills, MI; Bonnen, John Joseph Francis [Milford, MI
2012-03-20
An electro-hydraulic forming tool for forming a sheet metal blank in a one-sided die has first and second rigid rings that engage opposite sides of a sheet metal blank. The rigid rings are contained within slots on a die portion and a hydraulic force applicator portion of the forming tool. The seals are either resiliently biased by an elastomeric member or inherently resiliently biased into contact with the blank.
Large optical glass blanks for the ELT generation
NASA Astrophysics Data System (ADS)
Jedamzik, Ralf; Petzold, Uwe; Dietrich, Volker; Wittmer, Volker; Rexius, Olga
2016-07-01
The upcoming extremely large telescope projects like the E-ELT, TMT or GMT telescopes require not only large amount of mirror blank substrates but have also sophisticated instrument setups. Common instrument components are atmospheric dispersion correctors that compensate for the varying atmospheric path length depending on the telescope inclination angle. These elements consist usually of optical glass blanks that have to be large due to the increased size of the focal beam of the extremely large telescopes. SCHOTT has a long experience in producing and delivering large optical glass blanks for astronomical applications up to 1 m and in homogeneity grades up to H3 quality in the past. The most common optical glass available in large formats is SCHOTT N-BK7. But other glass types like F2 or LLF1 can also be produced in formats up to 1 m. The extremely large telescope projects partly demand atmospheric dispersion components even in sizes beyond 1m up to a range of 1.5 m diameter. The production of such large homogeneous optical glass banks requires tight control of all process steps. To cover this demand in the future SCHOTT initiated a research project to improve the large optical blank production process steps from melting to annealing and measurement. Large optical glass blanks are measured in several sub-apertures that cover the total clear aperture of the application. With SCHOTT's new stitching software it is now possible to combine individual sub-aperture measurements to a total homogeneity map of the blank. In this presentation first results will be demonstrated.
Dogandžić, Tamara; Braun, David R.; McPherron, Shannon P.
2015-01-01
Blank size and form represent one of the main sources of variation in lithic assemblages. They reflect economic properties of blanks and factors such as efficiency and use life. These properties require reliable measures of size, namely edge length and surface area. These measures, however, are not easily captured with calipers. Most attempts to quantify these features employ estimates; however, the efficacy of these estimations for measuring critical features such as blank surface area and edge length has never been properly evaluated. In addition, these parameters are even more difficult to acquire for retouched implements as their original size and hence indication of their previous utility have been lost. It has been suggested, in controlled experimental conditions, that two platform variables, platform thickness and exterior platform angle, are crucial in determining blank size and shape meaning that knappers can control the interaction between size and efficiency by selecting specific core angles and controlling where fracture is initiated. The robustness of these models has rarely been tested and confirmed in context other than controlled experiments. In this paper, we evaluate which currently employed caliper measurement methods result in the highest accuracy of size estimations of blanks, and we evaluate how platform variables can be used to indirectly infer aspects of size on retouched artifacts. Furthermore, we investigate measures of different platform management strategies that control the shape and size of artifacts. To investigate these questions, we created an experimental lithic assemblage, we digitized images to calculate 2D surface area and edge length, which are used as a point of comparison for the caliper measurements and additional analyses. The analysis of aspects of size determinations and the utility of blanks contributes to our understanding of the technological strategies of prehistoric knappers and what economic decisions they made during process of blank production. PMID:26332773
Gaudin, Valerie; Juhel-Gaugain, Murielle; Morétain, Jean-Pierre; Sanders, Pascal
2008-12-01
Premi Test contains viable spores of a strain of Bacillus stearothermophilus which is sensitive to antimicrobial residues, such as beta-lactams, tetracyclines, macrolides and sulphonamides. The growth of the strain is inhibited by the presence of antimicrobial residues in muscle tissue samples. Premi Test was validated according to AFNOR rules (French Association for Normalisation). The AFNOR validation was based on the comparison of reference methods (French Official method, i.e. four plate test (FPT) and the STAR protocol (five plate test)) with the alternative method (Premi Test). A preliminary study was conducted in an expert laboratory (Community Reference Laboratory, CRL) on both spiked and incurred samples (field samples). Several method performance criteria (sensitivity, specificity, relative accuracy) were estimated and are discussed, in addition to detection capabilities. Adequate agreement was found between the alternative method and the reference methods. However, Premi Test was more sensitive to beta-lactams and sulphonamides than the FPT. Subsequently, a collaborative study with 11 laboratories was organised by the CRL. Blank and spiked meat juice samples were sent to participants. The expert laboratory (CRL) statistically analysed the results. It was concluded that Premi Test could be used for the routine determination of antimicrobial residues in muscle of different animal origin with acceptable analytical performance. The detection capabilities of Premi Test for beta-lactams (amoxicillin, ceftiofur), one macrolide (tylosin) and tetracycline were at the level of the respective maximum residue limits (MRL) in muscle samples or even lower.
Quantitation and detection of vanadium in biologic and pollution materials
NASA Technical Reports Server (NTRS)
Gordon, W. A.
1974-01-01
A review is presented of special considerations and methodology for determining vanadium in biological and air pollution materials. In addition to descriptions of specific analysis procedures, general sections are included on quantitation of analysis procedures, sample preparation, blanks, and methods of detection of vanadium. Most of the information presented is applicable to the determination of other trace elements in addition to vanadium.
High-throughput imaging of heterogeneous cell organelles with an X-ray laser (CXIDB ID 25)
Hantke, Max, F.
2014-11-17
Preprocessed detector images that were used for the paper "High-throughput imaging of heterogeneous cell organelles with an X-ray laser". The CXI file contains the entire recorded data - including both hits and blanks. It also includes down-sampled images and LCLS machine parameters. Additionally, the Cheetah configuration file is attached that was used to create the pre-processed data.
Low-level (submicromole) environmental 14C metrology
NASA Astrophysics Data System (ADS)
Currie, L. A.; Kessler, J. D.; Marolf, J. V.; McNichol, A. P.; Stuart, D. R.; Donoghue, J. C.; Donahue, D. J.; Burr, G. S.; Biddulph, D.
2000-10-01
Accelerator mass spectrometry (AMS) measurements of environmental 14C have been employed during the past decade at the several micromole level (tens of μg carbon), but advanced research in the atmospheric and marine sciences demands still higher (μg) sensitivity, an extreme example being the determination of 14C in elemental or "black" carbon (BC) at levels of 2-10 μg per kg of Greenland snow and ice (Currie et al., 1998). A fundamental limitation for 14C AMS is Poisson counting statistics, which sets in at about 1 μg modern-C. Using the small sample (25 μg) AMS target preparation facility at NOSAMS (Pearson et al., 1998), and the microsample combustion-dilution facility at NIST, we have demonstrated an intrinsic modern-C quantification limit ( mQ) of ca. 0.9 μg, based on a 1-parameter fit to the empirical AMS variance function. (For environmental 14C, the modern carbon quantification limit is defined as that mass ( mQ) corresponding to 10% relative standard deviation (rsd) for the fraction of modern carbon, σ( fM)/ fM.) Stringent control, required for quantitative dilution factors (DL), is achieved with the NIST on-line manometric/mass spectrometry facility that compensates also for unsuspected trace impurities from vigorous chemical processing (e.g., acid digestion). Our current combustion blank is trivial (mean: 0.16 ± 0.02 μg C, n=13) but lognormally distributed (dispersion [σ]: 0.07 ± 0.01 μg). An iterative numerical expression is introduced to assess the quantitative impacts of fossil and modern carbon blank components on mQ; and a new "clean chemistry" BC processing system is described for the minimization of such blanks. For the assay of soot carbon in Greenland snow/ice, the overall processing blank has been reduced from nearly 7 μg total carbon to less than 1 μg, and is undetectable for BC.
1980-11-01
IZPT,ITH,IDEL,NTAP7,IAR,IAN,IUB, IGB(7) ,IVB,IU,IV,IW,IVA,IWA, ICP, IPHI,IYB,NAG,NAP,NAV,NAS, NASHK, NAFLD ,IAO,IDO,ISKO,TYIMI,IZIM,ISVN,ISKP,NRING,IROW...locations in blank common required in SOLVE NASHIK maximum locations in blank common required in BSHOCK NAFLD maximum locations in blank common
Furlong, E.T.; Martin, Jeffrey D.; Werner, S.L.; Gates, Paul M.
2002-01-01
The sensitivity and selective determination of polar pesticides were analyzed using high-performance liquid chromatography/electrospray ionization-mass spectrometry (HPLC/ESI-MS). The effects of multiple operators and instruments on method performance were evaluated using 440 pairs of fortified reagent-water and blank reagent-water samples. The influence of varying environmental matrices on recovery and precision were also analyzed using 200 fortified ambient water samples and duplicate ambient water samples. The results show that compound stability in filtered water was matrix-, chemical class- and compound-dependent which ranged from 1 day to 2 weeks.
Lithographic qualification of high-transmission mask blank for 10nm node and beyond
NASA Astrophysics Data System (ADS)
Xu, Yongan; Faure, Tom; Viswanathan, Ramya; Lobb, Granger; Wistrom, Richard; Burns, Sean; Hu, Lin; Graur, Ioana; Bleiman, Ben; Fischer, Dan; Mignot, Yann; Sakamoto, Yoshifumi; Toda, Yusuke; Bolton, John; Bailey, Todd; Felix, Nelson; Arnold, John; Colburn, Matthew
2016-04-01
In this paper, we discuss the lithographic qualification of high transmission (High T) mask for Via and contact hole applications in 10nm node and beyond. First, the simulated MEEF and depth of focus (DoF) data are compared between the 6% and High T attnPSM masks with the transmission of High T mask blank varying from 12% to 20%. The 12% High T blank shows significantly better MEEF and larger DoF than those of 6% attnPSM mask blank, which are consistent with our wafer data. However, the simulations show no obvious advantage in MEEF and DoF when the blank transmittance is larger than 12%. From our wafer data, it has been seen that the common process window from High T mask is 40nm bigger than that from the 6% attnPSM mask. In the elongated bar structure with smaller aspect ratio, 1.26, the 12% High T mask shows significantly less develop CD pull back in the major direction. Compared to the High T mask, the optimized new illumination condition for 6% attnPSM shows limited improvement in MEEF and the DoF through pitch. In addition, by using the High T mask blank, we have also investigated the SRAF printing, side lobe printing and the resist profile through cross sections, and no patterning risk has been found for manufacturing. As part of this work new 12% High T mask blank materials and processes were developed, and a brief overview of key mask technology development results have been shared. Overall, it is concluded that the High T mask, 12% transmission, provides the most robust and extendable lithographic solution for 10nm node and beyond.
Inspection of lithographic mask blanks for defects
Sommargren, Gary E.
2001-01-01
A visible light method for detecting sub-100 nm size defects on mask blanks used for lithography. By using optical heterodyne techniques, detection of the scattered light can be significantly enhanced as compared to standard intensity detection methods. The invention is useful in the inspection of super-polished surfaces for isolated surface defects or particulate contamination and in the inspection of lithographic mask or reticle blanks for surface defects or bulk defects or for surface particulate contamination.
Haack, Sheridan Kidd; Duris, Joseph W.
2008-01-01
A field trial was done in the Upper Tiffin River Watershed, in southeastern Michigan, to determine the influence of liquid dairy manure effluent (LDME) management practices on the quality of agricultural subsurface-drain water. Samples from subsurface drains were analyzed for nutrients, fecal-coliform and Escherichia coli (E. coli) bacteria, antibiotics, chemicals typically detected in wastewater, and the occurrence of genes indicating the presence of shiga-toxin-producing E. coli, or of bovine-specific Bacteroidetes bacteria. Samples were collected from November 2, 2006, to March 20, 2007, from eight subsurface drains under field plots that received no LDME and no tillage (controls) or received 4,000 or 8,000 gallons per acre (gal/acre) of LDME and either no tillage or two different types of tillage. The two types of tillage tested were (1) ground-driven, rotary, subsurface cultivation and (2) rolling-tine aeration. Samples were collected before LDME application and at 4 hours, and 1, 2, 6, 7, and 14 days post-application. Nutrient concentrations were high in subsurface-drain water throughout the field-trial period and could not be attributed to the field-trial LDME application. Of the 59 drain-water samples, including those collected before LDME application and control samples for each date, 56 had concentrations greater than the U.S. Environmental Protection Agency (USEPA), Ecoregion VI recommended surface-water criterion for total phosphorus, and all samples had concentrations greater than the recommended total nitrogen criterion. Nitrate + nitrite nitrogen concentration exceeded 20 milligrams per liter for every sample and contributed most to the total nitrogen concentrations. Substantial increases in drain-water concentrations of organic and ammonia nitrogen and total phosphorus were found for all treatments, including controls, at 14 days post-application after 0.84 inch of rainfall over 2 days. E. coli concentrations exceeded the USEPA recreational-water-quality single-sample criterion of 235 colony forming units per 100 milliliters in only 3 of 56 samples. Of these three samples, two were collected within 1 day post-LDME application from the treatment receiving 8,000 gal/acre LDME with no tillage (NT8000). The third sample was from the rolling-tine aerator treatment with 4,000 gal/acre LDME application rate after the first significant rainfall. Two wastewater chemicals and two bacterial genes (eaeA and stx1) detected in the LDME, but absent in field blank or pre-application samples, were detected in the 4-hour or 1-day postapplication NT8000 samples. No LDME-associated chemicals were detected in later samples from the NT8000 treatment, and none were detected in samples from other treatments after the first significant rainfall. Results of this field trial were somewhat equivocal with respect to the influence of LDME concentration and tillage practices on subsurface-drain water quality, both immediately after LDME application and in the longer term, after significant rainfall. Interpretation of study findings is limited by the fact that treatments were not replicated, and flow rate or discharge from the subsurface drains was not measured. Nevertheless, study results provide useful information about nutrient and bacteria concentrations in subsurface drains during the non-growing season. In addition, study results demonstrate some potential for the use of chemical and microbiological indicators of LDME transport to subsurface drains.
Van den Driessche, Charlotte; Bastian, Mikaël; Peyre, Hugo; Stordeur, Coline; Acquaviva, Éric; Bahadori, Sara; Delorme, Richard; Sackur, Jérôme
2017-10-01
People with attention-deficit/hyperactivity disorder (ADHD) have difficulties sustaining their attention on external tasks. Such attentional lapses have often been characterized as the simple opposite of external sustained attention, but the different types of attentional lapses, and the subjective experiences to which they correspond, remain unspecified. In this study, we showed that unmedicated children (ages 6-12) with ADHD, when probed during a standard go/no-go task, reported more mind blanking (a mental state characterized by the absence of reportable content) than did control participants. This increase in mind blanking happened at the expense of both focused and wandering thoughts. We also found that methylphenidate reverted the level of mind blanking to baseline (i.e., the level of mind blanking reported by control children without ADHD). However, this restoration led to mind wandering more than to focused attention. In a second experiment, we extended these findings to adults who had subclinical ADHD. These results suggest that executive functions impaired in ADHD are required not only to sustain external attention but also to maintain an internal train of thought.
CLASH: A census of magnified star-forming galaxies at z ∼ 6-8
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bradley, L. D.; Coe, D.; Postman, M.
2014-09-01
We utilize 16 band Hubble Space Telescope (HST) observations of 18 lensing clusters obtained as part of the Cluster Lensing And Supernova survey with Hubble (CLASH) Multi-Cycle Treasury program to search for z ∼ 6-8 galaxies. We report the discovery of 204, 45, and 13 Lyman-break galaxy candidates at z ∼ 6, z ∼ 7, and z ∼ 8, respectively, identified from purely photometric redshift selections. This large sample, representing nearly an order of magnitude increase in the number of magnified star-forming galaxies at z ∼ 6-8 presented to date, is unique in that we have observations in four WFC3/UVISmore » UV, seven ACS/WFC optical, and all five WFC3/IR broadband filters, which enable very accurate photometric redshift selections. We construct detailed lensing models for 17 of the 18 clusters to estimate object magnifications and to identify two new multiply lensed z ≳ 6 candidates. The median magnifications over the 17 clusters are 4, 4, and 5 for the z ∼ 6, z ∼ 7, and z ∼ 8 samples, respectively, over an average area of 4.5 arcmin{sup 2} per cluster. We compare our observed number counts with expectations based on convolving 'blank' field UV luminosity functions through our cluster lens models and find rough agreement down to ∼27 mag, where we begin to suffer significant incompleteness. In all three redshift bins, we find a higher number density at brighter observed magnitudes than the field predictions, empirically demonstrating for the first time the enhanced efficiency of lensing clusters over field surveys. Our number counts also are in general agreement with the lensed expectations from the cluster models, especially at z ∼ 6, where we have the best statistics.« less
Marcos-Campos, I; Asín, L; Torres, T E; Marquina, C; Tres, A; Ibarra, M R; Goya, G F
2011-05-20
In this work, the capability of primary, monocyte-derived dendritic cells (DCs) to uptake iron oxide magnetic nanoparticles (MNPs) is assessed and a strategy to induce selective cell death in these MNP-loaded DCs using external alternating magnetic fields (AMFs) is reported. No significant decrease in the cell viability of MNP-loaded DCs, compared to the control samples, was observed after five days of culture. The number of MNPs incorporated into the cytoplasm was measured by magnetometry, which confirmed that 1-5 pg of the particles were uploaded per cell. The intracellular distribution of these MNPs, assessed by transmission electron microscopy, was found to be primarily inside the endosomic structures. These cells were then subjected to an AMF for 30 min and the viability of the blank DCs (i.e. without MNPs), which were used as control samples, remained essentially unaffected. However, a remarkable decrease of viability from approximately 90% to 2-5% of DCs previously loaded with MNPs was observed after the same 30 min exposure to an AMF. The same results were obtained using MNPs having either positive (NH(2)(+)) or negative (COOH(-)) surface functional groups. In spite of the massive cell death induced by application of AMF to MNP-loaded DCs, the number of incorporated magnetic particles did not raise the temperature of the cell culture. Clear morphological changes at the cell structure after magnetic field application were observed using scanning electron microscopy. Therefore, local damage produced by the MNPs could be the main mechanism for the selective cell death of MNP-loaded DCs under an AMF. Based on the ability of these cells to evade the reticuloendothelial system, these complexes combined with an AMF should be considered as a potentially powerful tool for tumour therapy.
Evaluation of Urban Air Quality By Passive Sampling Technique
NASA Astrophysics Data System (ADS)
Nunes, T. V.; Miranda, A. I.; Duarte, S.; Lima, M. J.
Aveiro is a flat small city in the centre of Portugal, close to the Atlantic coast. In the last two decades an intensive development of demographic, traffic and industry growth in the region was observed which was reflected on the air quality degrada- tion. In order to evaluate the urban air quality in Aveiro, a field-monitoring network by passive sampling with high space resolution was implemented. Twenty-four field places were distributed in a area of 3x3 Km2 and ozone and NO2 concentrations were measured. The site distribution density was higher in the centre, 250x250 m2 than in periphery where a 500x500 m2 grid was used. The selection of field places took into consideration the choice criteria recommendation by United Kingdom environmental authorities, and three tubes and a blank tube for each pollutant were used at each site. The sampling system was mounted at 3m from the ground usually profiting the street lampposts. Concerning NO2 acrylic tubes were used with 85 mm of length and an in- ternal diameter of 12mm, where in one of the extremities three steel grids impregnated with a solution of TEA were placed and fixed with a polyethylene end cup (Heal et al., 1999); PFA Teflon tube with 53 mm of length and 9 mm of internal diameter and three impregnated glass filters impregnated with DPE solution fixed by a teflon end cup was used for ozone sampling (Monn and Hargartner, 1990). The passive sampling method for ozone and nitrogen dioxide was compared with continuous measurements, but the amount of measurements wasnSt enough for an accurate calibration and validation of the method. Although this constraint the field observations (June to August 2001) for these two pollutants assign interesting information about the air quality in the urban area. A krigger method of interpolation (Surfer- Golden Software-2000) was applied to field data to obtain isolines distribution of NO2 and ozone concentration for the studied area. Even the used passive sampling method has many limitations it is possi- ble to say that the NO2 concentrations were strictly related with traffic intensity and in the centre 3 to 10 times higher values were observed than the incoming air to the city; on the contrary the ozone seems to be consumed where we observe the highest NO2 concentrations. Heal, M. R.; O'Donoghue, M. A. and Cape, J. N., Overestimation of Urban Nitrogen Dioxide by Passive Sampling Tubes: a comparative exposure and model study, Atmo- spheric Environment, Vol 33, pp 513-524, 1999 Monn, Ch., Hangartner, M., Passive Sampling for Ozone, J. of Air and Waste Management Association, Vol. 40, Nz 3, 1990
NASA Astrophysics Data System (ADS)
Jedamzik, Ralf; Westerhoff, Thomas
2017-09-01
The coefficient of thermal expansion (CTE) and its spatial homogeneity from small to large formats is the most important property of ZERODUR. Since more than a decade SCHOTT has documented the excellent CTE homogeneity. It started with reviews of past astronomical telescope projects like the VLT, Keck and GTC mirror blanks and continued with dedicated evaluations of the production. In recent years, extensive CTE measurements on samples cut from randomly selected single ZERODUR parts in meter size and formats of arbitrary shape, large production boules and even 4 m sized blanks have demonstrated the excellent CTE homogeneity in production. The published homogeneity data shows single ppb/K peak to valley CTE variations on medium spatial scale of several cm down to small spatial scale of only a few mm mostly at the limit of the measurement reproducibility. This review paper summarizes the results also in respect to the increased CTE measurement accuracy over the last decade of ZERODUR production.
Kubachka, Kevin; Heitkemper, Douglas T; Conklin, Sean
2017-07-01
Before being designated AOAC First Action Official MethodSM 2016.04, the U.S. Food and Drug Administration's method, EAM 4.10 High Performance Liquid Chromatography-Inductively Coupled Plasma-Mass Spectrometric Determination of Four Arsenic Species in Fruit Juice, underwent both a single-laboratory validation and a multilaboratory validation (MLV) study. Three federal and five state regulatory laboratories participated in the MLV study, which is the primary focus of this manuscript. The method was validated for inorganic arsenic (iAs) measured as the sum of the two iAs species arsenite [As(III)] and arsenate [As(V)], dimethylarsinic acid (DMA), and monomethylarsonic acid (MMA) by analyses of 13 juice samples, including three apple juice, three apple juice concentrate, four grape juice, and three pear juice samples. In addition, two water Standard Reference Materials (SRMs) were analyzed. The method LODs and LOQs obtained among the eight laboratories were approximately 0.3 and 2 ng/g, respectively, for each of the analytes and were adequate for the intended purpose of the method. Each laboratory analyzed method blanks, fortified method blanks, reference materials, triplicate portions of each juice sample, and duplicate fortified juice samples (one for each matrix type) at three fortification levels. In general, repeatability and reproducibility of the method was ≤15% RSD for each species present at a concentration >LOQ. The average recovery of fortified analytes for all laboratories ranged from 98 to 104% iAs, DMA, and MMA for all four juice sample matrixes. The average iAs results for SRMs 1640a and 1643e agreed within the range of 96-98% of certified values for total arsenic.
Herath, H M D R; Shaw, P N; Cabot, P; Hewavitharana, A K
2010-06-15
The high-performance liquid chromatography (HPLC) column is capable of enrichment/pre-concentration of trace impurities in the mobile phase during the column equilibration, prior to sample injection and elution. These impurities elute during gradient elution and result in significant chromatographic peaks. Three types of purified water were tested for their impurity levels, and hence their performances as mobile phase, in HPLC followed by total ion current (TIC) mode of MS. Two types of HPLC-grade water produced 3-4 significant peaks in solvent blanks while LC/MS-grade water produced no peaks (although peaks were produced by LC/MS-grade water also after a few days of standing). None of the three waters produced peaks in HPLC followed by UV-Vis detection. These peaks, if co-eluted with analyte, are capable of suppressing or enhancing the analyte signal in a MS detector. As it is not common practice to run solvent blanks in TIC mode, when quantification is commonly carried out using single ion monitoring (SIM) or single or multiple reaction monitoring (SRM or MRM), the effect of co-eluting impurities on the analyte signal and hence on the accuracy of the results is often unknown to the analyst. Running solvent blanks in TIC mode, regardless of the MS mode used for quantification, is essential in order to detect this problem and to take subsequent precautions. Copyright (c) 2010 John Wiley & Sons, Ltd.
Mathany, Timothy M.; Burton, Carmen A.; Land, Michael; Belitz, Kenneth
2010-01-01
Groundwater quality in the approximately 766-square-mile South Coast Range-Coastal (SCRC) study unit was investigated from May to December 2008, as part of the Priority Basins Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basins Project was developed in response to legislative mandates (Supplemental Report of the 1999 Budget Act 1999-00 Fiscal Year; and, the Groundwater Quality Monitoring Act of 2001 [Sections 10780-10782.3 of the California Water Code, Assembly Bill 599]) to assess and monitor the quality of groundwater in California, and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The SCRC study unit was the 25th study unit to be sampled as part of the GAMA Priority Basins Project. The SCRC study unit was designed to provide a spatially unbiased assessment of untreated groundwater quality in the primary aquifer systems and to facilitate statistically consistent comparisons of untreated groundwater quality throughout California. The primary aquifer systems (hereinafter referred to as primary aquifers) were defined as that part of the aquifer corresponding to the perforation interval of wells listed in the California Department of Public Health (CDPH) database for the SCRC study unit. The quality of groundwater in shallow or deep water-bearing zones may differ from the quality of groundwater in the primary aquifers; shallow groundwater may be more vulnerable to surficial contamination. In the SCRC study unit, groundwater samples were collected from 70 wells in two study areas (Basins and Uplands) in Santa Barbara and San Luis Obispo Counties. Fifty-five of the wells were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study unit (grid wells), and 15 wells were selected to aid in evaluation of specific water-quality issues (understanding wells). In addition to the 70 wells sampled, 3 surface-water samples were collected in streams near 2 of the sampled wells in order to better comprehend the interaction between groundwater and surface water in the area. The groundwater samples were analyzed for organic constituents (volatile organic compounds [VOC], pesticides and pesticide degradates, polar pesticides and metabolites, and pharmaceutical compounds), constituents of special interest (perchlorate, N-nitrosodimethylamine [NDMA], and 1,2,3-TCP), naturally occurring inorganic constituents (trace elements, nutrients, dissolved organic carbon [DOC], major and minor ions, silica, total dissolved solids [TDS], and alkalinity), and radioactive constituents (gross alpha and gross beta radioactivity). Naturally occurring isotopes (stable isotopes of hydrogen and oxygen in water, stable isotopes of nitrogen and oxygen in dissolved nitrate, stable isotopes of sulfur in dissolved sulfate, stable isotopes of carbon in dissolved inorganic carbon, activities of tritium, and carbon-14 abundance), and dissolved gases (including noble gases) also were measured to help identify the sources and ages of the sampled groundwater. In total, 298 constituents and field water-quality indicators were investigated. Three types of quality-control samples (blanks, replicates, and matrix-spikes) were collected at approximately 3 to 12 percent of the wells in the SCRC study unit, and the results for these samples were used to evaluate the quality of the data for the groundwater samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that contamination from sample collection procedures was not a significant source of bias in the data for the groundwater samples. Differences between replicate samples generally were less than 10 percent relative and/or standard deviation, indicating acceptable analytical reproducibility. Matrix-spike recoveries were within the acceptable range (70 to 130 percent) for approximately 84
RMA Abandoned Well Closure Program. Final Task Plan, Version 3.0.
1989-05-01
20503. 1 . AGENCY USE ONLY (Leave blank) 2. REPORT DATE" 0 3. REPORT TYPE AND DATES COVERED _T 05/00/89 __________________ 4. TITLE AND SUBTITLE S...AQUIFERS. THE SCOPE OF WORK INCLUDES: 1 . COMPILATION OF A WELL INVENTORY AND DATABASE 2. FIELD LOCATION OF WELLS 3. CLEANING AND CLOSURE OF...APPROXIMATELY 350 WELT- 4. DOCUMENTATION OF CLOSURE ACTIVITIES. SECTIONS OF THIS TASK PLAN DETAIL-INFORMATION ON: 1 . ABANDONED WELL IDENTIFICATION AND LOCATION
Mann, Rajinder S; Rouseff, Russell L; Smoot, Jack; Rao, Nandikeswara; Meyer, Wendy L; Lapointe, Stephen L; Robbins, Paul S; Cha, Dong; Linn, Charles E; Webster, Francis X; Tiwari, Siddharth; Stelinski, Lukasz L
2013-06-01
Huanglongbing (HLB) is the most destructive disease of citrus worldwide. The Asian citrus psyllid, Diaphorina citri Kuwayama (Hemiptera: Psyllidae), is the vector of the phloem-inhabiting bacterium, Candidatus Liberibacter asiaticus, which is presumed to cause HLB in Florida citrus. Laboratory and field studies were conducted to examine the behavioral responses of male and female D. citri to their cuticular extracts. In olfactometer assays, more male D. citri were attracted to one, five, or 10 female cuticular extract equivalent units than blank controls. The results were confirmed in field studies in which clear or yellow traps baited with 10 female cuticular extract equivalent units attracted proportionately more males than clear traps baited with male cuticular extract or unbaited traps. Analyses of cuticular constituents of male and female D. citri revealed differences between the sexes in chemical composition of their cuticular extracts. Laboratory bioassays with synthetic chemicals identified from cuticular extracts indicated that dodecanoic acid attracted more males than clean air. Traps baited with dodecanoic acid did not increase total catch of D. citri as compared with blank traps at the dosages tested; however, the sex ratio of psyllid catch was male biased on traps baited with the highest lure loading dosage tested (10.0 mg). © 2012 The Authors Insect Science © 2012 Institute of Zoology, Chinese Academy of Sciences.
Fabrication High Resolution Metrology Target By Step And Repeat Method
NASA Astrophysics Data System (ADS)
Dusa, Mircea
1983-10-01
Based on the photolithography process generally used to generate high resolution masks for semiconductor I.C.S, we found a very useful industrial application of laser technology.First, we have generated high resolution metrology targets which are used in industrial measurement laser interferometers as difra.ction gratings. Secondi we have generated these targets using step and repeat machine, with He-Ne laser interferometer controlled state, as a pattern generator, due to suitable computer programming.Actually, high resolution metrology target, means two chromium plates, one of which is called the" rule" the other one the "vernier". In Fig.1 we have the configuration of the rule and the vernier. The rule has a succesion of 3 μM lines generated as a difraction grating on a 4 x 4 inch chromium blank. The vernier has several exposed fields( areas) having 3 - 15 μm lines, fields placed on very precise position on the chromium blank surface. High degree of uniformity, tight CD tolerances, low defect density required by the targets, creates specialised problems during processing. Details of the processing, together with experimental results will be presented. Before we start to enter into process details, we have to point out that the dimensional requirements of the reticle target, are quite similar or perhaps more strict than LSI master casks. These requirements presented in Fig.2.
1991-03-01
forms: ". ..application blanks, biographical inventories , interviews, work sample tests, and intelligence, aptitude, and personality tests" (1:11...the grouping method, 3) the task method, and 4) the knowledge , skills, abilities (KSA) method. The point method of measuring training/experience assigns... knowledge , skills, abilities, and other characteristics which relate specifically to each job element (3:131). Interview. According to N. Schmitt
A Novel Hydrogel-Based Biosampling Approach
2016-03-01
MONITORING AGENCY NAME(S) AND ADDRESS(ES) U.S. Army Edgewood Chemical Biological Center Seedling Program, APG, MD 21010-5424 10. SPONSOR/MONITOR’S...Std. Z39.18 ii Blank iii PREFACE The work described in this report was authorized under the U.S. Army Edgewood Chemical Biological...a complex area of intensive, ongoing research. After a biorelease event, sampling is at the core of all pre- and post- decontamination analyses
Image Descriptors for Displays
1975-03-01
sampled with composite blanking signal; (c) signal in (a) formed into composite video signal ... 24 3. Power spectral density of the signals shown in...Curve A: composite video signal formed from 20 Hz to 2.5 MH.i band-limited, Gaussian white noise. Curve B: average spectrum of off-the-air video...previously. Our experimental procedure was the following. Off-the-air television signals broadcast on VHP channels were analyzed with a commercially
Fluid Structure Interaction Effects on Composites Under Low Velocity Impact
2012-06-01
Nanotubes ( MWCNTs ) and the second had no reinforcements at the interface layer in front of the pre-cracks. Output from both tests was recorded using...these samples were tested. The first was reinforced with Multi-Walled Carbon Nanotubes ( MWCNTs ) and the second had no reinforcements at the interface...Ethyl Ketone Peroxide MWCNT Multi-Walled Carbon Nanotube VARTM Vacuum-Assisted Resin Transfer Molding xiv THIS PAGE INTENTIONALLY LEFT BLANK
Prototypes of Cognitive Measures for Air Force Officers: Test Development and Item Banking
1990-05-01
with the complexity of the relationship. Relationships may be in terms of shape, size, dimensionality, area of embeddedness , rotation, blank/shaded...administration were used. Test directions were read from the booklet. Demographics and test responses were recorded on a machine-scannable answer sheet...as demographic information would be needed to determine whether sample characteristics accounted for the differences in mean scores for NC, FA, and WD
Improved electron probe microanalysis of trace elements in quartz
Donovan, John J.; Lowers, Heather; Rusk, Brian G.
2011-01-01
Quartz occurs in a wide range of geologic environments throughout the Earth's crust. The concentration and distribution of trace elements in quartz provide information such as temperature and other physical conditions of formation. Trace element analyses with modern electron-probe microanalysis (EPMA) instruments can achieve 99% confidence detection of ~100 ppm with fairly minimal effort for many elements in samples of low to moderate average atomic number such as many common oxides and silicates. However, trace element measurements below 100 ppm in many materials are limited, not only by the precision of the background measurement, but also by the accuracy with which background levels are determined. A new "blank" correction algorithm has been developed and tested on both Cameca and JEOL instruments, which applies a quantitative correction to the emitted X-ray intensities during the iteration of the sample matrix correction based on a zero level (or known trace) abundance calibration standard. This iterated blank correction, when combined with improved background fit models, and an "aggregate" intensity calculation utilizing multiple spectrometer intensities in software for greater geometric efficiency, yields a detection limit of 2 to 3 ppm for Ti and 6 to 7 ppm for Al in quartz at 99% t-test confidence with similar levels for absolute accuracy.
Attenuated phase-shift mask (PSM) blanks for flat panel display
NASA Astrophysics Data System (ADS)
Kageyama, Kagehiro; Mochizuki, Satoru; Yamakawa, Hiroyuki; Uchida, Shigeru
2015-10-01
The fine pattern exposure techniques are required for Flat Panel display applications as smart phone, tablet PC recently. The attenuated phase shift masks (PSM) are being used for ArF and KrF photomask lithography technique for high end pattern Semiconductor applications. We developed CrOx based large size PSM blanks that has good uniformity on optical characteristics for FPD applications. We report the basic optical characteristics and uniformity, stability data of large sized CrOx PSM blanks.
Evaluation on determination of iodine in coal by energy dispersive X-ray fluorescence
Wang, B.; Jackson, J.C.; Palmer, C.; Zheng, B.; Finkelman, R.B.
2005-01-01
A quick and inexpensive method of relative high iodine determination from coal samples was evaluated. Energy dispersive X-ray fluorescence (EDXRF) provided a detection limit of about 14 ppm (3 times of standard deviations of the blank sample), without any complex sample preparation. An analytical relative standard deviation of 16% was readily attainable for coal samples. Under optimum conditions, coal samples with iodine concentrations higher than 5 ppm can be determined using this EDXRF method. For the time being, due to the general iodine concentrations of coal samples lower than 5 ppm, except for some high iodine content coal, this method can not effectively been used for iodine determination. More work needed to meet the requirement of determination of iodine from coal samples for this method. Copyright ?? 2005 by The Geochemical Society of Japan.
THE DETERMINATION OF TRACES OF IRON IN SAMPLES OF PLATINUM BY NE TRON- ACTIVATION ANALYSIS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morris, D.F.C.; Killick, R.A.
1963-11-01
A neutron-activation analysis method for the determination of traces of iron in samples of purified platinum is described. The nuclear reactor BEPO at Harwell was used as the neutron source. A rapid radiochemical separation procedure using carriers was employed to decontaminate the iron activity from most other induced activities. The analysis is completed by discriminated gamma scintillation counting. Results of analyses of seven samples of platinum are quoted. The method of analysis has the advantage that it obviates difficulties caused by reagent blanks or by contamination from traces of inactive iron after irradiation. Interference resulting from nuclear reactions of elementsmore » other than iron in the samples appears to be of no consequence. (auth)« less
Rapid, quantitative determination of bacteria in water. [adenosine triphosphate
NASA Technical Reports Server (NTRS)
Chappelle, E. W.; Picciolo, G. L.; Thomas, R. R.; Jeffers, E. L.; Deming, J. W. (Inventor)
1978-01-01
A bioluminescent assay for ATP in water borne bacteria is made by adding nitric acid to a water sample with concentrated bacteria to rupture the bacterial cells. The sample is diluted with sterile, deionized water, then mixed with a luciferase-luciferin mixture and the resulting light output of the bioluminescent reaction is measured and correlated with bacteria present. A standard and a blank also are presented so that the light output can be correlated to bacteria in the sample and system noise can be substracted from the readings. A chemiluminescent assay for iron porphyrins in water borne bacteria is made by adding luminol reagent to a water sample with concentrated bacteria and measuring the resulting light output of the chemiluminescent reaction.
Concentration Dependence of VO2+ Crossover of Nafion for Vanadium Redox Flow Batteries
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lawton, Jamie; Jones, Amanda; Zawodzinski, Thomas A
2013-01-01
The VO2+ crossover, or permeability, through Nafion in a vanadium redox flow battery (VRFB) was monitored as a function of sulfuric acid concentration and VO2+ concentration. A vanadium rich solution was flowed on one side of the membrane through a flow field while symmetrically on the other side a blank or vanadium deficit solution was flowed. The blank solution was flowed through an electron paramagnetic resonance (EPR) cavity and the VO2+ concentration was determined from the intensity of the EPR signal. Concentration values were fit using a solution of Fick s law that allows for the effect of concentration changemore » on the vanadium rich side. The fits resulted in permeability values of VO2+ ions across the membrane. Viscosity measurements of many VO2+ and H2SO4 solutions were made at 30 60 C. These viscosity values were then used to determine the effect of the viscosity of the flowing solution on the permeability of the ion. 2013 The Electrochemical Society. [DOI: 10.1149/2.004306jes] All rights reserved.« less
Applications of Computer Simulation Methods in Plastic Forming Technologies for Magnesium Alloys
NASA Astrophysics Data System (ADS)
Zhang, S. H.; Zheng, W. T.; Shang, Y. L.; Wu, X.; Palumbo, G.; Tricarico, L.
2007-05-01
Applications of computer simulation methods in plastic forming of magnesium alloy parts are discussed. As magnesium alloys possess very poor plastic formability at room temperature, various methods have been tried to improve the formability, for example, suitable rolling process and annealing procedures should be found to produce qualified magnesium alloy sheets, which have the reduced anisotropy and improved formability. The blank can be heated to a warm temperature or a hot temperature; a suitable temperature field is designed, tools should be heated or the punch should be cooled; suitable deformation speed should be found to ensure suitable strain rate range. Damage theory considering non-isothermal forming is established. Various modeling methods have been tried to consider above situations. The following situations for modeling the forming process of magnesium alloy sheets and tubes are dealt with: (1) modeling for predicting wrinkling and anisotropy of sheet warm forming; (2) damage theory used for predicting ruptures in sheet warm forming; (3) modeling for optimizing of blank shape and dimensions for sheet warm forming; (4) modeling in non-steady-state creep in hot metal gas forming of AZ31 tubes.
Spices as a source of lead exposure: a market-basket survey in Sri Lanka.
Senanayake, M P; Perera, R; Liyanaarachchi, L A; Dassanayake, M P
2013-12-01
We performed a laboratory analysis of spices sold in Sri Lanka for lead content. Samples of curry powder, chili powder and turmeric powder from seven provinces, collected using the market basket survey method, underwent atomic absorption spectrometry. Blanks and standards were utilised for instrument calibration and measurement accuracy. The results were validated in two different laboratories. All samples were found to have lead levels below the US Food and Drug Administration's action level of 0.5 μg/g. Spices sold in Sri Lanka contain lead concentrations that are low and within the stipulated safety standards.
NASA Technical Reports Server (NTRS)
Arevalo, Ricardo, Jr.; Coyle, Barry; Paulios, Demetrios; Stysley, Paul; Feng, Steve; Getty, Stephanie; Binkerhoff, William
2015-01-01
Compared to wet chemistry and pyrolysis techniques, in situ laser-based methods of chemical analysis provide an ideal way to characterize precious planetary materials without requiring extensive sample processing. In particular, laser desorption and ablation techniques allow for rapid, reproducible and robust data acquisition over a wide mass range, plus: Quantitative, spatially-resolved measurements of elemental and molecular (organic and inorganic) abundances; Low analytical blanks and limits-of-detection ( ng g-1); and, the destruction of minimal quantities of sample ( g) compared to traditional solution and/or pyrolysis analyses (mg).
Advanced defect classification by smart sampling, based on sub-wavelength anisotropic scatterometry
NASA Astrophysics Data System (ADS)
van der Walle, Peter; Kramer, Esther; Ebeling, Rob; Spruit, Helma; Alkemade, Paul; Pereira, Silvania; van der Donck, Jacques; Maas, Diederik
2018-03-01
We report on advanced defect classification using TNO's RapidNano particle scanner. RapidNano was originally designed for defect detection on blank substrates. In detection-mode, the RapidNano signal from nine azimuth angles is added for sensitivity. In review-mode signals from individual angles are analyzed to derive additional defect properties. We define the Fourier coefficient parameter space that is useful to study the statistical variation in defect types on a sample. By selecting defects from each defect type for further review by SEM, information on all defects can be obtained efficiently.
NASA Technical Reports Server (NTRS)
Stern, J. C.; Malespin, C. A.; Eigenbrode, J. L.; Graham, H. V.; Archer, P. D., Jr.; Brunner, A. E.; Freissinet, C.; Franz, H. B.; Fuentes, J.; Glavin, D. P.;
2014-01-01
The combustion experiment on the Sample Analysis at Mars (SAM) suite on Curiosity will heat a sample of Mars regolith in the presence of oxygen and measure composition of the evolved gases using quadrupole mass spectrometry (QMS) and tunable laser spectrometry (TLS). QMS will enable detection of combustion products such as CO, CO2, NO, and other oxidized species, while TLS will enable precise measurements of the abundance and carbon isotopic composition (delta(sup 13)C) of the evolved CO2 and hydrogen isotopic composition (deltaD) of H2O. SAM will perform a two-step combustion to isolate combustible materials below approx.550 C and above approx.550 C. The combustion experiment on SAM, if properly designed and executed, has the potential to answer multiple questions regarding the origins of volatiles seen thus far in SAM evolved gas analysis (EGA) on Mars. Constraints imposed by SAM and MSL time and power resources, as well as SAM consumables (oxygen gas), will limit the number of SAM combustion experiments, so it is imperative to design an experiment targeting the most pressing science questions. Low temperature combustion experiments will primarily target the quantification of carbon (and nitrogen) contributed by SAM wet chemistry reagants MTBSTFA (N-Methyl-N-tert-butyldimethylsilyltrifluoroacetamide) and DMF (Dimethylformamide), which have been identified in the background of blank and sample runs and may adsorb to the sample while the cup is in the Sample Manipulation System (SMS). In addition, differences between the sample and "blank" may yield information regarding abundance and delta(sup 13)C of bulk (both organic and inorganic) martian carbon. High temperature combustion experiments primarily aim to detect refractory organic matter, if present in Cumberland fines, as well as address the question of quantification and deltaD value of water evolution associated with hydroxyl hydrogen in clay minerals.
Ondigo, Bartholomew N; Park, Gregory S; Gose, Severin O; Ho, Benjamin M; Ochola, Lyticia A; Ayodo, George O; Ofulla, Ayub V; John, Chandy C
2012-12-21
Multiplex cytometric bead assay (CBA) have a number of advantages over ELISA for antibody testing, but little information is available on standardization and validation of antibody CBA to multiple Plasmodium falciparum antigens. The present study was set to determine optimal parameters for multiplex testing of antibodies to P. falciparum antigens, and to compare results of multiplex CBA to ELISA. Antibodies to ten recombinant P. falciparum antigens were measured by CBA and ELISA in samples from 30 individuals from a malaria endemic area of Kenya and compared to known positive and negative control plasma samples. Optimal antigen amounts, monoplex vs multiplex testing, plasma dilution, optimal buffer, number of beads required were assessed for CBA testing, and results from CBA vs. ELISA testing were compared. Optimal amounts for CBA antibody testing differed according to antigen. Results for monoplex CBA testing correlated strongly with multiplex testing for all antigens (r = 0.88-0.99, P values from <0.0001 - 0.004), and antibodies to variants of the same antigen were accurately distinguished within a multiplex reaction. Plasma dilutions of 1:100 or 1:200 were optimal for all antigens for CBA testing. Plasma diluted in a buffer containing 0.05% sodium azide, 0.5% polyvinylalcohol, and 0.8% polyvinylpyrrolidone had the lowest background activity. CBA median fluorescence intensity (MFI) values with 1,000 antigen-conjugated beads/well did not differ significantly from MFI with 5,000 beads/well. CBA and ELISA results correlated well for all antigens except apical membrane antigen-1 (AMA-1). CBA testing produced a greater range of values in samples from malaria endemic areas and less background reactivity for blank samples than ELISA. With optimization, CBA may be the preferred method of testing for antibodies to P. falciparum antigens, as CBA can test for antibodies to multiple recombinant antigens from a single plasma sample and produces a greater range of values in positive samples and lower background readings for blank samples than ELISA.
Fu, Z-X; Han, J-S; Liu, F; Zhao, Z-L; Li, D-B; Shi, L; Dong, J-T; Zhou, Y; Cai, J-H
2017-05-01
This study is to observe the immunosuppression of CD137L transfected umbilical blood Dcs (Dendritic cell) vaccine to tumor development of SCID/ Beige nude mice. Samples of umbilical blood in the childbirth pregnant women were collected by density gradient centrifugation. Umbilical cord blood dendritic cells (Dcs) were transfected by specific CD137L via LipofectamineTM method and cells were harvested. Meanwhile, the peripheral blood of volunteers was collected to isolate Dcs, the Dcs were cultured for 5 days and hatched with SW-1116 cells antigen. The mature Dcs were harvested. The male SCID/Beige nude mice were subcutaneously injected with human SW-1116 cells in axillary to build colorectal carcinoma model as blank control (Blank). The naked peripheral blood Dc vaccine group (cPBMCs), the SW-1116 antigen-specific peripheral blood Dc vaccine group (pDcs) and the CD137L specific umbilical blood Dc vaccine group (tuDcs) were injected 24 h before tumor cells injection, respectively to recur the humanized immune reconstruction. The general life, living habits changes, tumor growing time and tumor size were observed. The nude mice were sacrificed 18 days after tumor formation. The tumor size, mice weight, in vitro tumor weight, liver weight and spleen weight of mice were recorded to evaluate the anti-tumor effect of the specific immune cells. The nude mice in pDcs group showed better general living condition, slower tumor growth, smaller tumor volume and no ulceration, necrosis, and death in nude mice. The tumor formation time in different groups was 4.71 ± 0.18 ds (blank), 7.71 ± 0.29 ds (cPBMCs), 7.86 ± 0.26 ds (pDcs) and 8.14 ± 0.69 ds (tuDcs) respectively. There were significant differences between blank and other three groups (F = 40.96, p < 0.01). Compared to mice in blank group, the tumor volume of cPBMCs group was significantly smaller (201.43 ± 69.84 mm³ vs. 436.04 ± 54.50 mm³, p < 0.01) and the tumor weight were significantly smaller (1.25 ± 0.12 g vs. 2.83 ± 0.24 g, p < 0.01). The tumor volume of tuDcs mice was significantly smaller than that of blank (92.11 ± 11.55 mm³ vs. 436.04 ± 54.50 mm³, p < 0.01) and cPBMCs mice (92.11 ± 11.55 mm³ vs. 201.43 ± 69.84 mm³, p < 0.01). Similarly, the tumor weight of tuDcs mice was significantly smaller than that of blank (0.66 ± 0.07 g vs. 2.83 ± 0.24 g, p < 0.01) and cPBMCs mice (0.66 ± 0.07 g vs. 1.25 ± 0.12 g, p < 0.01). There was no significant difference in tumor volume (92.11 ± 11.55 mm³ vs. 85.61 ± 11.59 mm³, p = 0.69) and tumor weight (0.66 ± 0.07 g vs. 0.63 ± 0.09 g, p = 0.75) between tuDcs group and pDcs group. The specific CD137L transfected umbilical blood Dc vaccine had significant anti-tumor effect against human colon cancer in nude mice via increasing the number of immune effector cell in tumor microenvironment.
Krempa, Heather M.
2015-10-29
Relative percent differences between methods were greater than 10 percent for most analyzed trace elements. Barium, cobalt, manganese, and boron had concentrations that were significantly different between sampling methods. Barium, molybdenum, boron, and uranium method concentrations indicate a close association between pump and grab samples based on bivariate plots and simple linear regressions. Grab sample concentrations were generally larger than pump concentrations for these elements and may be because of using a larger pore sized filter for grab samples. Analysis of zinc blank samples suggests zinc contamination in filtered grab samples. Variations of analyzed trace elements between pump and grab samples could reduce the ability to monitor temporal changes and potential groundwater contamination threats. The degree of precision necessary for monitoring potential groundwater threats and application objectives need to be considered when determining acceptable variation amounts.
Skinner, Kenneth D.
2018-05-11
Groundwater-quality samples and water-level data were collected from 36 wells in the Jerome/Gooding County area of the eastern Snake River Plain aquifer during June 2017. The wells included 30 wells sampled for the U.S. Geological Survey’s National Water-Quality Assessment project, plus an additional 6 wells were selected to increase spatial distribution. The data provide water managers with the ability for an improved understanding of groundwater quality and flow directions in the area. Groundwater-quality samples were analyzed for nutrients, major ions, trace elements, and stable isotopes of water. Quality-assurance and quality-control measures consisted of multiple blank samples and a sequential replicate sample. All data are available online at the USGS National Water Information System.
Enabling high speed friction stir welding of aluminum tailor welded blanks
NASA Astrophysics Data System (ADS)
Hovanski, Yuri
Current welding technologies for production of aluminum tailor-welded blanks (TWBs) are utilized in low-volume and niche applications, and have yet to be scaled for the high-volume vehicle market. This study targeted further weight reduction, part reduction, and cost savings by enabling tailor-welded blank technology for aluminum alloys at high-volumes. While friction stir welding (FSW) has traditionally been applied at linear velocities less than one meter per minute, high volume production applications demand the process be extended to higher velocities more amenable to cost sensitive production environments. Unfortunately, weld parameters and performance developed and characterized at low to moderate welding velocities do not directly translate to high speed linear friction stir welding. Therefore, in order to facilitate production of high volume aluminum FSW components, parameters were developed with a minimum welding velocity of three meters per minute. With an emphasis on weld quality, welded blanks were evaluated for post-weld formability using a combination of numerical and experimental methods. Evaluation across scales was ultimately validated by stamping full-size production door inner panels made from dissimilar thickness aluminum tailor-welded blanks, which provided validation of the numerical and experimental analysis of laboratory scale tests.
Porous mandrels provide uniform deformation in hydrostatic powder metallurgy
NASA Technical Reports Server (NTRS)
Gripshover, P. J.; Hanes, H. D.
1967-01-01
Porous copper mandrels prevent uneven deformation of beryllium machining blanks. The beryllium powder is arranged around these mandrels and hot isostatically pressed to form the blanks. The mandrels are then removed by leaching.
76 FR 37063 - Marine Mammals; File No. 16510
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-24
... Blank Park Zoo [Kevin V. Drees, Responsible Party], 7401 SW. Ninth, Des Moines, IA 50315, has applied in... Vancouver Aquarium, Vancouver, Canada for purposes of public display at the Blank Park Zoo. The receiving...
2013-09-01
less like adversaries and more like partners with the affected communities in the effort. 94 THIS PAGE INTENTIONALLY LEFT BLANK 95 LIST OF... INTENTIONALLY LEFT BLANK i REPORT DOCUMENTATION PAGE Form Approved OMB No. 0704–0188 Public reporting burden for this collection of information is...ABSTRACT UU NSN 7540–01–280–5500 Standard Form 298 (Rev. 2–89) Prescribed by ANSI Std. 239–18 ii THIS PAGE INTENTIONALLY LEFT BLANK iii Approved
Super-Resolution Algorithm in Cumulative Virtual Blanking
NASA Astrophysics Data System (ADS)
Montillet, J. P.; Meng, X.; Roberts, G. W.; Woolfson, M. S.
2008-11-01
The proliferation of mobile devices and the emergence of wireless location-based services have generated consumer demand for precise location. In this paper, the MUSIC super-resolution algorithm is applied to time delay estimation for positioning purposes in cellular networks. The goal is to position a Mobile Station with UMTS technology. The problem of Base-Stations herability is solved using Cumulative Virtual Blanking. A simple simulator is presented using DS-SS signal. The results show that MUSIC algorithm improves the time delay estimation in both the cases whether or not Cumulative Virtual Blanking was carried out.
2011-12-01
UU NSN 7540–01–280–5500 Standard Form 298 (Rev. 8–98) Prescribed by ANSI Std. Z39.18 ii THIS PAGE INTENTIONALLY LEFT BLANK iii Approved for...modeled using the finite element analysis simulation code, ANSYS 13.0. The main objective of these simulations was to determine the location at which...transient response of the test plate under FSI conditions, computational studies were carried out in ANSYS 13.0 Multi-field (MFX) simulation
2004-06-01
PAGE INTENTIONALLY LEFT BLANK v ABSTRACT Thermophotovoltaic cells are a good candidate for use in high efficiency radioiso- tope...ongoing in this field since the 1950’s, but the exotic materials necessary for high efficiency cells has only been recently available. Here, several...This cell was able to operate at 24% efficiency which is very high for a silicon cell [Ref. 6]. The inverted pyramids labeled in the figure are
Small Tactical Unmanned Aerial System (STUAS) Rapid Integration and Fielding Process (RAIN)
2013-09-01
121A4 September 2013 Thesis Advisor: Rama Gehris Co-Advisor: Bonnie Young THIS PAGE INTENTIONALLY LEFT BLANK i REPORT...11~ ... . , - ... $tlo.rotfydle:IW#hlt I •:tl ~dciwolloCII’fil -K ~IOI’I.,....UMdto~~h..,orj ’Bj ~ $11owh~t:~I) Cft .... l’utopK i7, MtM rf Mtdlar...Trndc-off Anolysis Rcsulls ’ll•c trnde-ofl’ Analysis results will be a summary of tho conclusions derived from incorporating aml analyzing tho
Unit Materiel Fielding Point Europe.
1985-10-01
NCAO to other non-AMC staging sites was the most costly alternative with respect to transportation. 33 1b This page left blank intentionally. 34...DIFFERFNT TYPES) wILL RE CONS’OL- IOATEn AT THE ncAO UMFP A. T TMHTN TIPE. PROJFCTEI) RFOUIREMENTS FOR rOVFREn STORAr;F AT THE F-Za REMAT~i WFLL RFLOWt TOTAL...subject as above. b. Letter, AMXLC-S, your HO, 13 Jun 85, subject: NCAO UMFP Analysis (Report Number 514101). 2. Reference la requested supply data on
Systems Engineering Processes for the Acquisition of Prognostic and Health Management Systems
2012-09-01
INTRODUCTION A. BACKGROUND Prior to the F-35 Joint Strike Fighter (JSF) Program, the A-7 Corsair II was the last single engine fighter in the Navy...first fielded on the A-7 Corsair to the CBM+ systems being developed for the F-35 JSF. It also identified the DoD directive that mandates the...LEFT BLANK 55 LIST OF REFERENCES [1] A-7 Corsair II. (2011, July 7). GlobalSecurity.org. [Online]. Available: http://www.globalsecurity.org
Evaluation of TF11 attenuated-PSM mask blanks with DUV laser patterning
NASA Astrophysics Data System (ADS)
Xing, Kezhao; Björnberg, Charles; Karlsson, Henrik; Paulsson, Adisa; Beiming, Peter; Vedenpää, Jukka; Walford, Jonathan
2008-05-01
Tightening requirements on resolution, CD uniformity and positional accuracy push the development of improved photomask blanks. One such blank for 45nm node attenuated phase shift masks (att-PSM) provides a thinner chrome film, TF11, with a higher etch rate compared to previous generation NTAR5 att-PSM blanks from the same supplier. FEP-171, a positive chemically amplified resist, is commonly used in mask manufacturing for both e-beam and DUV laser pattern generators. TF11 chrome allows the FEP-171 resist thickness to be decreased at least down to 2000 Å while maintaining sufficient etch resistance, thereby improving photomask CD performance. The lower stress level in TF11 chrome films also reduces the image placement error induced by the material. In this study, TF11 chrome and FEP-171 resist are evaluated with exposures on a 248 nm DUV laser pattern generator, the Sigma7500. Patterning is first characterized for resist thicknesses of 2000 Å to 2600 Å in steps of 100 Å, assessing the minimum feature resolution, CD linearity, isolated-dense CD bias and dose sensitivity. Swing curve analysis shows a minimum near 2200 Å and a maximum near 2500 Å, corresponding closely to the reflectivity measurements provided by the blank supplier. The best overall patterning performance is obtained when operating near the swing maximum. The patterning performance is then studied in more detail with a resist thickness of 2550 Å that corresponds to the reflectivity maximum. This is compared to the results with 2000 Å resist, a standard thickness for e-beam exposures on TF11. The lithographic performance on NTAR5 att-PSM blanks with 3200 Å resist is also included for reference. This evaluation indicates that TF11 blanks with 2550 Å resist provide the best overall mask patterning performance obtained with the Sigma7500, showing a global CD uniformity below 4 nm (3s) and minimum feature resolution below 100 nm.
Schölvinck, D W; Alvarez Herrero, L; Visser, M; Bergman, J J G H M; Weusten, B L A M
2015-10-01
Preliminary data show higher stricture rates after radiofrequency ablation (RFA) for early esophageal squamous neoplasia compared with Barrett's esophagus. We studied the effects of Lugol stain (LS) directly prior to RFA on stricture formation in squamous epithelium. Of 16 pigs, the distal half of the esophagus was LS, followed by circumferential RFA (single application 12 J/cm(2) ) in the unstained and stained esophagus. Pigs were euthanized at day 0 (n = 4), 3 (n = 4), or 28 (n = 8). Histology was evaluated in four areas: blank-control (no RFA, no LS), blank-RFA (no LS), LS+RFA, and LS-control (no RFA). Stenosis severity in LS+RFA and blank-RFA at 28 days was assessed by the ratio of the mucosal diameter at the RFA area to the diameter 2 cm proximal of this zone. Histology showed submucosal edema in 50% of LS+RFA versus 0% in blank-RFA. Severity and depth of inflammation (day 3) was equal in LS+RFA and blank-RFA. Severity and depth of fibrosis (day 28) appeared more severe in LS+RFA. Consequently, stenosis was present in 100% (LS+RFA) versus 12.5% (blank-RFA). The stenosis-severity ratio was 0.40 (interquartile range 0.29-0.45) in LS+RFA versus 0.73 (interquartile range 0.64-0.78) in blank-RFA (P = 0.012). Limitations of this study were the difference in uptake of LS between pigs and humans, the difference in esophageal anatomy between pigs and humans, and between the proximal and distal esophagus within pigs. In conclusion, in the porcine squamous esophagus, stenosis rate and severity after RFA increased when preceded by LS. LS may be contributing in the altered response of squamous epithelium to RFA as compared with Barrett's esophagus. © 2014 International Society for Diseases of the Esophagus.
Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.
2009-01-01
The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance and quality-control data were stored in the laboratory's Lab Master data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality control samples analyzed from July 2005 through June 2007. Results for the quality-control samples for 19 analytical procedures were evaluated for bias and precision. Control charts indicate that data for eight of the analytical procedures were occasionally biased for either high-concentration or low-concentration samples but were within control limits; these procedures were: total aluminum, calcium, magnesium, nitrate (colorimetric method), potassium, silicon, sodium, and sulfate. Eight of the analytical procedures were biased throughout the analysis period for the high-concentration sample, but were within control limits; these procedures were: total aluminum, calcium, dissolved organic carbon, chloride, nitrate (ion chromatograph), potassium, silicon, and sulfate. The magnesium and pH procedures were biased throughout the analysis period for the low-concentration sample, but were within control limits. The acid-neutralizing capacity, total monomeric aluminum, nitrite, and specific conductance procedures were biased for the high-concentration and low-concentration samples, but were within control limits. Results from the filter-blank and analytical-blank analyses indicated that the procedures for 16 of 17 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. The data-quality objective was not met for dissolved organic carbon. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 18 of the 21 analytes. At least 93 percent of the samples met data-quality objectives for all analytes except acid-neutralizing capacity (85 percent of samples met objectives), total monomeric aluminum (83 percent of samples met objectives), total aluminum (85 percent of samples met objectives), and chloride (85 percent of samples met objectives). The ammonium and total dissolved nitrogen did not meet the data-quality objectives. Results of the USGS interlaboratory Standard Reference Sample (SRS) Project met the Troy Laboratory data-quality objectives for 87 percent of the samples analyzed. The P-sample (low-ionic-strength constituents) analysis had two outliers each in two studies. The T-sample (trace constituents) analysis and the N-sample (nutrient constituents) analysis had one outlier each in two studies. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 85 percent of the samples met data-quality objectives for 11 of the 14 analytes; the exceptions were acid-neutralizing capacity, total aluminum and ammonium. Data-quality objectives were not met in 41 percent of samples analyzed for acid-neutralizing capacity, 50 percent of samples analyzed for total aluminum, and 44 percent of samples analyzed for ammonium. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 86 percent of the samples analyzed for calcium, magnesium, pH, potassium, and sodium. Data-quality objectives were met by 76 percent of the samples analyzed for chloride, 80 percent of the samples analyzed for specific conductance, and 77 percent of the samples analyzed for sulfate.
Method and apparatus for continuously referenced analysis of reactive components in solution
Bostick, W.D.; Denton, M.S.; Dinsmore, S.R.
1979-07-31
A continuously referenced apparatus for measuring the concentration of a reactive chemical species in solution comprises in combination conduit means for introducing a sample solution, means for introducing one or more reactants into a sample solution, and a stream separator disposed within the conduit means for separating the sample solution into a first sample stream and a second sample stream. A reactor is disposed in fluid communication with the first sample stream. A reaction takes place between the reactants introduced and the reactive chemical species of interest, causing the consumption or production of an indicator species in the first sample stream. Measurement means such as a photometric system are disposed in communication with the first and second sample streams, and the outputs of the measurement means are compared to provide a blanked measurement of the concentration of indicator species. The apparatus is particularly suitable for measurement of isoenzymes in body tissues or fluids.
Fatalities caused by spherical bullets fired from blank cartridge guns in Istanbul, Turkey.
Uzün, Ibrahim; Büyük, Yalçin; Erkol, Zerrin; Ağritmiş, Hasan; Kir, Ziya
2009-09-01
Blank cartridge guns are generally regarded as being harmless and are not considered to be firearms in the legal sense in most countries. To show the danger of these guns upon simple modifications, we report 59 fatalities resulting from these simply modified blank cartridge guns in Istanbul, Turkey. The great majority of the victims were males and the age of those ranged from 11 to 61 years. In 55.9% of these cases, homicide was the origin followed by suicide (39%). The right temporal region was detected to be the preferred region in suicidal shots by blank cartridge guns with a frequency of 56.5%. In trial shots, all these guns were detected to discharge steel or lead spherical objects, generally 4 or 5 mm in diameter, successfully. Our findings strongly suggest that these guns should also be considered as handguns in the legal sense.
Failure Analysis of a Sheet Metal Blanking Process Based on Damage Coupling Model
NASA Astrophysics Data System (ADS)
Wen, Y.; Chen, Z. H.; Zang, Y.
2013-11-01
In this paper, a blanking process of sheet metal is studied by the methods of numerical simulation and experimental observation. The effects of varying technological parameters related to the quality of products are investigated. An elastoplastic constitutive equation accounting for isotropic ductile damage is implemented into the finite element code ABAQUS with a user-defined material subroutine UMAT. The simulations of the damage evolution and ductile fracture in a sheet metal blanking process have been carried out by the FEM. In order to guarantee computation accuracy and avoid numerical divergence during large plastic deformation, a specified remeshing technique is successively applied when severe element distortion occurs. In the simulation, the evolutions of damage at different stage of the blanking process have been evaluated and the distributions of damage obtained from simulation are in proper agreement with the experimental results.
The sound insulations of studio doors. Part 1: Door blanks
NASA Astrophysics Data System (ADS)
Plumb, G. D.; Clark, R.
The sound insulations of a range of different door blanks were measured. The results were compared with the sound insulations of existing BBC door blanks. The new doors were made from medium density fiberboard (MDF) which is more stable than the blockboard used in existing studio doors. Consequently, they should require less maintenance and adjustment and should have a longer lifespan. The doors had higher sound insulations for their weight than existing designs, which might permit savings in the costs of the surrounding building structures. Overall construction costs of the door blanks themselves are likely to be similar to those of existing designs. A companion Report (BBC RD 1994/15) describes sound insulation measurements made on plant-on door seals. The intention of this work was to simplify the construction of the door frame and the fitting of the seals to reduce costs.
High Precision Low-blank Lithium Isotope Ratios in Forams.
NASA Astrophysics Data System (ADS)
Misra, S.; Froelich, P. N.
2007-12-01
We present a high precision (±1‰, 2σ) low blank (<500 fg/ml) method for Li isotope measurements of forams using <2 ng of Li by single collector Quad ICP-MS (Agilent 7500cs). The Li isotope ratio of seawater (δ7Li) recorded in planktonic forams has the potential to constrain the evolution of seawater chemistry and elucidate the factors driving variations of oceanic mass balances linked to the continental and sea floor/hydrothermal silica cycles. In addition a δ7Li record of seawater will complement other long-term recorders of seawater chemistry such as Sr, Os and S isotopes. Li isotope measurements of forams are limited by several factors: low Li concentrations in forams (1-2 ppm), instrument-induced fractionation and mass bias effects, matrix effects, high Li blanks and incomplete recovery of Li during column separation. Modest concentrations of alkali and alkaline earth elements in the matrix result in variable mass bias in measured Li isotope ratios. Even worse, Li strongly fractionates during chromatographic clean-up to remove Na+, Ca2+ and Mg2+, from +100‰ in the leading edge to - 100‰ in the trailing edge of elution peaks (Urey 1938). Consequently, miniscule incomplete recoveries of Li during chromatographic separations can result in large unrecognized isotope fractionation of eluents. Large mass-dependent fractionation caused by a difference of 17% in mass between 6Li and 7Li, makes Li a powerful tracer of geochemical processes, but also promotes large and difficult-to-fix isotope fractionations during laboratory chemical processing. Matrix effects of Na & Ca and of column chromatography on Li isotope ratios were investigated using artificial Li solutions representative of foram compositions (matrix matching). Li/Ca and Li/Na ratios in cleaned forams are 10 μmol/mol and 3 mmol/mol respectively. An ICP-MS tolerance limit of 20 ppb for Na and 20 μM for Ca was established, much higher tolerances than by TIMS. A single step chromatographic method to quantitatively separate Li from matrix elements using both small volume resin (3.4 meq/2ml AG50W-X8) and acid (6 ml of 0.5N HCl) was developed. Our low blank (<0.5 pg/ml) and high yield (>99.99%) column method minimizes errors in measured Li isotope ratios associated with incomplete column recovery and presence of matrix elements. High sensitivity and precision achieved with a 7500cs using cold plasma (600W), soft extraction and peak jumping coupled with very low sample to blank ratios enables high precision (±1‰, 2σ) statistically significant Li isotope measurements using very small mass of Li (0.8 ng). The development of this technique makes possible good quality Li isotope measurements from samples that are mass limited for Li, i.e., reasonable number of picked forams. This will enable us to test interferences regarding chemical cleaning and species effects in planktonic forams along the road toward creating a δ7Li record of seawater for the Cenozoic.
McCleskey, R. Blaine; Nordstrom, D. Kirk; Naus, Cheryl A.
2004-01-01
The Questa baseline and pre-mining ground-water quality investigation has the main objective of inferring the ground-water chemistry at an active mine site. Hence, existing ground-water chemistry and its quality assurance and quality control is of crucial importance to this study and a substantial effort was spent on this activity. Analyses of seventy-two blanks demonstrated that contamination from processing, handling, and analyses were minimal. Blanks collected using water deionized with anion and cation exchange resins contained elevated concentrations of boron (0.17 milligrams per liter (mg/L)) and silica (3.90 mg/L), whereas double-distilled water did not. Boron and silica were not completely retained by the resins because they can exist as uncharged species in water. Chloride was detected in ten blanks, the highest being 3.9 mg/L, probably as the result of washing bottles, filter apparatuses, and tubing with hydrochloric acid. Sulfate was detected in seven blanks; the highest value was 3.0 mg/L, most likely because of carryover from the high sulfate waters sampled. With only a few exceptions, the remaining blank analyses were near or below method detection limits. Analyses of standard reference water samples by cold-vapor atomic fluorescence spectrometry, ion chromatography, inductively coupled plasma-optical emission spectrometry, inductively coupled plasma-mass spectrometry, FerroZine, graphite furnace atomic absorption spectrometry, hydride generation atomic spectrometry, and titration provided an accuracy check. For constituents greater than 10 times the detection limit, 95 percent of the samples had a percent error of less than 8.5. For constituents within 10 percent of the detection limit, the percent error often increased as a result of measurement imprecision. Charge imbalance was calculated using WATEQ4F and 251 out of 257 samples had a charge imbalance less than 11.8 percent. The charge imbalance for all samples ranged from -16 to 16 percent. Spike recoveries were performed by spiking ground-water samples from SC2B, SC3A, SC3B, CC2A, and Hottentot with a mixed-element standard and then analyzing them by ICP-OES. The mean recovery for all the constituents by ICP-OES was 103 percent with a standard deviation of 16 percent. Fifteen surface- and ground-water sequential duplicates were collected from Straight Creek, Hottentot, and the Red River from 2002 to 2003. Except for chloride from well SC5B and low concentrations of iron (<0.05 mg/L) and aluminum (<0.01 mg/L), constituents of sequential duplicates are generally within 10 percent of each other. Analytical results from different methods and different laboratories, with rare exceptions, were within 10 percent. Chromium analyses were in poor agreement when comparing analyses from the USGS and a contract laboratory, but USGS analyses by ICP-OES and ICP-MS were usually within 10 percent for chromium concentrations above 0.03 mg/L and analyses by ICP-OES and GFAAS were usually within 15 percent for chromium concentrations as much as 0.1 mg/L.Filtration studies also were performed to study the effects of filtration apparatuses (Minitan, plate, capsule, and syringe), pore sizes, and timing on dissolved metal concentrations. Except for iron and aluminum, constituents with concentrations greater than about 0.05 mg/L were generally not affected by the filtration apparatus, membrane pore-size, and filtration delays. Iron, aluminum, and some dissolved metals concentrations less than about 0.05 mg/L, especially copper, were generally lowest in filtrates from the tangential flow Minitan system containing a filter membrane with a pore size of 10,000 Daltons. As part of a filtration timing study, grab samples were collected from two sites along the Red River and were processed immediately and then again 1 to 3 hours later. Aluminum and iron colloids formed during the delay in the sample collected at the USGS gaging station and, after the delay, 0.1-ìm filtrate aluminum and iron concentrations approached the ultrafiltrate (Minitan) concentrations. In the upstream site below Fawn Lakes, aluminum in the 0.1-ìm filtrate decreased but did not decrease in the 0.45-ìm filtrate, signifying that the colloids formed during the delay are between 0.1 and 0.45 ìm. Dissolved nickel and pH also decreased in both samples during the delay. Except for ferrous iron and barium, a sequential filtration study 2 demonstrated that water collected from the Red River at the gage did not affect dissolved metal concentrations with increasing sample volume passing through a plate filter with 0.45- or 0.1-ìm membranes. Barium and ferrous iron both slightly decreased in the filtrate from the 0.45-ìm filter.
Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.
2009-01-01
The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance and quality-control data were stored in the laboratory's Lab Master data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality control samples analyzed from July 2003 through June 2005. Results for the quality-control samples for 20 analytical procedures were evaluated for bias and precision. Control charts indicate that data for five of the analytical procedures were occasionally biased for either high-concentration or low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, total monomeric aluminum, pH, silicon, and sodium. Seven of the analytical procedures were biased throughout the analysis period for the high-concentration sample, but were within control limits; these procedures were: dissolved organic carbon, chloride, nitrate (ion chromatograph), nitrite, silicon, sodium, and sulfate. The calcium and magnesium procedures were biased throughout the analysis period for the low-concentration sample, but were within control limits. The total aluminum and specific conductance procedures were biased for the high-concentration and low-concentration samples, but were within control limits. Results from the filter-blank and analytical-blank analyses indicate that the procedures for 17 of 18 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. The data-quality objective was not met for dissolved organic carbon. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 18 of the 22 analytes. At least 85 percent of the samples met data-quality objectives for all analytes except total monomeric aluminum (82 percent of samples met objectives), total aluminum (77 percent of samples met objectives), chloride (80 percent of samples met objectives), fluoride (76 percent of samples met objectives), and nitrate (ion chromatograph) (79 percent of samples met objectives). The ammonium and total dissolved nitrogen did not meet the data-quality objectives. Results of the USGS interlaboratory Standard Reference Sample (SRS) Project indicated good data quality over the time period, with ratings for each sample in the satisfactory, good, and excellent ranges or less than 10 percent error. The P-sample (low-ionic-strength constituents) analysis had one marginal and two unsatisfactory ratings for the chloride procedure. The T-sample (trace constituents)analysis had two unsatisfactory ratings and one high range percent error for the aluminum procedure. The N-sample (nutrient constituents) analysis had one marginal rating for the nitrate procedure. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 84 percent of the samples met data-quality objectives for 11 of the 14 analytes; the exceptions were ammonium, total aluminum, and acid-neutralizing capacity. The ammonium procedure did not meet data quality objectives in all studies. Data-quality objectives were not met in 23 percent of samples analyzed for total aluminum and 45 percent of samples analyzed acid-neutralizing capacity. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 86 percent of the samples analyzed for calcium, chloride, fluoride, magnesium, pH, potassium, sodium, and sulfate. Data-quality objectives were not met by samples analyzed for fluoride.
ZERODUR 4-m blank surviving up to 20 g acceleration
NASA Astrophysics Data System (ADS)
Westerhoff, Thomas; Werner, Thomas; Gehindy, Thorsten
2017-09-01
The glass ceramic ZERODUR developed as astronomical telescope mirror substrate material has been widely used in many telescopes due to its excellent small coefficient of thermal expansion. Many large and medium sized mirror substrate blanks have been delivered in the almost 50 years of ZERODUR business so far. Packaging and transportation of mirror substrates of 4 to 8 m in diameter with a weight between 3 and 20 tons requires special attention and sophisticated skills to successful deliver the blanks to their destination at polishing shops all over the world. Typically, a combination of road and sea transport needs to be organized. The requirements on the transport container are depending on the transport route and may vary from destination to destination. In any case the container needs to be able to sufficiently support the multi ton ZERODUR blank to avoid breaking under gravity. Additionally, the configuration needs to be able to absorb shocks happening during transport and loading between truck trailer and ship. For insurance reasons the transport container is always equipped with a GPS trackable shock recorder allowing to download the recorded accelerations on the container and the blank throughout the entire journey. This paper reports on the event of a 4 m class ZERODUR blank exposed to shocks up to 20 g during transport. The event will be discussed in detail together with lessons learned to avoid such events for future transports. Additionally, the 20 g acceleration will be discussed in respect to the data on bending strength for ZERODUR ground surfaces reported in numerous papers by Peter Hartmann et.al. in the last couple of years.
Fram, Miranda S.; Munday, Cathy; Belitz, Kenneth
2009-01-01
Groundwater quality in the approximately 460-square-mile Tahoe-Martis study unit was investigated in June through September 2007 as part of the Priority Basin Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin Project was developed in response to the Groundwater Quality Monitoring Act of 2001 and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The study was designed to provide a spatially unbiased assessment of the quality of raw groundwater used for public water supplies within the Tahoe-Martis study unit (Tahoe-Martis) and to facilitate statistically consistent comparisons of groundwater quality throughout California. Samples were collected from 52 wells in El Dorado, Placer, and Nevada Counties. Forty-one of the wells were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study area (grid wells), and 11 were selected to aid in evaluation of specific water-quality issues (understanding wells). The groundwater samples were analyzed for a large number of synthetic organic constituents (volatile organic compounds [VOC], pesticides and pesticide degradates, and pharmaceutical compounds), constituents of special interest (perchlorate and N-nitrosodimethylamine [NDMA]), naturally occurring inorganic constituents (nutrients, major and minor ions, and trace elements), radioactive constituents, and microbial indicators. Naturally occurring isotopes (tritium, carbon-14, strontium isotope ratio, and stable isotopes of hydrogen and oxygen of water), and dissolved noble gases also were measured to help identify the sources and ages of the sampled groundwater. In total, 240 constituents and water-quality indicators were investigated. Three types of quality-control samples (blanks, replicates, and samples for matrix spikes) each were collected at 12 percent of the wells, and the results obtained from these samples were used to evaluate the quality of the data for the groundwater samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that data for the groundwater samples were not compromised by possible contamination during sample collection, handling or analysis. Differences between replicate samples were within acceptable ranges. Matrix spike recoveries were within acceptable ranges for most compounds. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, raw water typically is treated, disinfected, or blended with other waters to maintain water quality. Regulatory thresholds apply to water that is served to the consumer, not to raw groundwater. However, to provide some context for the results, concentrations of constituents measured in the raw groundwater were compared with regulatory and nonregulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and the California Department of Public Health (CDPH), and with aesthetic and technical thresholds established by CDPH. Comparisons between data collected for this study and drinking-water thresholds are for illustrative purposes only and do not indicate of compliance or noncompliance with regulatory thresholds. The concentrations of most constituents detected in groundwater samples from the Tahoe-Martis wells were below drinking-water thresholds. Organic compounds (VOCs and pesticides) were detected in about 40 percent of the samples from grid wells, and most concentrations were less than 1/100th of regulatory and nonregulatory health-based thresholds, although the conentration of perchloroethene in one sample was above the USEPA maximum contaminant level (MCL-US). Concentrations of all trace elements and nutrients in samples from grid wells were below regulatory and nonregulatory health-based thresholds, with five exceptions. Concentra
2. D Street facade and rear (east) blank wall of ...
2. D Street facade and rear (east) blank wall of parking garage. Farther east is 408 8th Street (National Art And Frame Company). - PMI Parking Garage, 403-407 Ninth Street, Northwest, Washington, District of Columbia, DC
Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.
2009-01-01
The laboratory for analysis of low-ionic-strength water at the U.S. Geological Survey (USGS) Water Science Center in Troy, N.Y., analyzes samples collected by USGS projects throughout the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures that were developed to ensure proper sample collection, processing, and analysis. The quality-assurance and quality-control data were stored in the laboratory's Lab Master data-management system, which provides efficient review, compilation, and plotting of data. This report presents and discusses results of quality-assurance and quality control samples analyzed from July 2001 through June 2003. Results for the quality-control samples for 19 analytical procedures were evaluated for bias and precision. Control charts indicate that data for six of the analytical procedures were occasionally biased for either high-concentration or low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, chloride, magnesium, nitrate (ion chromatography), potassium, and sodium. The calcium procedure was biased throughout the analysis period for the high-concentration sample, but was within control limits. The total monomeric aluminum and fluoride procedures were biased throughout the analysis period for the low-concentration sample, but were within control limits. The total aluminum, pH, specific conductance, and sulfate procedures were biased for the high-concentration and low-concentration samples, but were within control limits. Results from the filter-blank and analytical-blank analyses indicate that the procedures for 16 of 18 analytes were within control limits, although the concentrations for blanks were occasionally outside the control limits. The data-quality objective was not met for the dissolved organic carbon or specific conductance procedures. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in the procedures for 18 of the 21 analytes. At least 90 percent of the samples met data-quality objectives for all procedures except total monomeric aluminum (83 percent of samples met objectives), total aluminum (76 percent of samples met objectives), ammonium (73 percent of samples met objectives), dissolved organic carbon (86 percent of samples met objectives), and nitrate (81 percent of samples met objectives). The data-quality objective was not met for the nitrite procedure. Results of the USGS interlaboratory Standard Reference Sample (SRS) Project indicated satisfactory or above data quality over the time period, with most performance ratings for each sample in the good-to-excellent range. The N-sample (nutrient constituents) analysis had one unsatisfactory rating for the ammonium procedure in one study. The T-sample (trace constituents) analysis had one unsatisfactory rating for the magnesium procedure and one marginal rating for the potassium procedure in one study and one unsatisfactory rating for the sodium procedure in another. Results of Environment Canada's National Water Research Institute (NWRI) program indicated that at least 90 percent of the samples met data-quality objectives for 10 of the 14 analytes; the exceptions were acid-neutralizing capacity, ammonium, dissolved organic carbon, and sodium. Data-quality objectives were not met in 37 percent of samples analyzed for acid-neutralizing capacity, 28 percent of samples analyzed for dissolved organic carbon, and 30 percent of samples analyzed for sodium. Results indicate a positive bias for the ammonium procedure in one study and a negative bias in another. Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 90 percent of the samples analyzed for calcium, chloride, magnesium, pH, potassium, and sodium. Data-quality objectives were met by 78 percent of
NASA Astrophysics Data System (ADS)
Drake, A. B.; Garel, T.; Wisotzki, L.; Leclercq, F.; Hashimoto, T.; Richard, J.; Bacon, R.; Blaizot, J.; Caruana, J.; Conseil, S.; Contini, T.; Guiderdoni, B.; Herenz, E. C.; Inami, H.; Lewis, J.; Mahler, G.; Marino, R. A.; Pello, R.; Schaye, J.; Verhamme, A.; Ventou, E.; Weilbacher, P. M.
2017-11-01
We present the deepest study to date of the Lyα luminosity function in a blank field using blind integral field spectroscopy from MUSE. We constructed a sample of 604 Lyα emitters (LAEs) across the redshift range 2.91 < z < 6.64 using automatic detection software in the Hubble Ultra Deep Field. The deep data cubes allowed us to calculate accurate total Lyα fluxes capturing low surface-brightness extended Lyα emission now known to be a generic property of high-redshift star-forming galaxies. We simulated realistic extended LAEs to fully characterise the selection function of our samples, and performed flux-recovery experiments to test and correct for bias in our determination of total Lyα fluxes. We find that an accurate completeness correction accounting for extended emission reveals a very steep faint-end slope of the luminosity function, α, down to luminosities of log10L erg s-1< 41.5, applying both the 1 /Vmax and maximum likelihood estimators. Splitting the sample into three broad redshift bins, we see the faint-end slope increasing from -2.03-0.07+ 1.42 at z ≈ 3.44 to -2.86-∞+0.76 at z ≈ 5.48, however no strong evolution is seen between the 68% confidence regions in L∗-α parameter space. Using the Lyα line flux as a proxy for star formation activity, and integrating the observed luminosity functions, we find that LAEs' contribution to the cosmic star formation rate density rises with redshift until it is comparable to that from continuum-selected samples by z ≈ 6. This implies that LAEs may contribute more to the star-formation activity of the early Universe than previously thought, as any additional intergalactic medium (IGM) correction would act to further boost the Lyα luminosities. Finally, assuming fiducial values for the escape of Lyα and LyC radiation, and the clumpiness of the IGM, we integrated the maximum likelihood luminosity function at 5.00
Bressy, C; Hellio, C; Marechal, J P; Tanguy, B; Margaillan, A
2010-10-01
This paper focuses on the activity spectrum of three dimethylalkyl tertiary amines as potential active molecules and the corresponding ammonium salt-based antifouling (AF) paints. Bioassays (using marine bacteria, microalgae and barnacles) and field tests were combined to assess the AF activity of coatings. Bioassay results demonstrated that the ammonium salt-based paints did not inhibit the growth of microorganisms (except the dimethyldodecylammonium-based coatings) and that the tertiary amines were potent towards bacteria, diatoms, and barnacle larvae at non-toxic concentrations (therapeutic ratio, LC50/EC50, <1). The results from field tests indicated that the ammonium salt-based coatings inhibited the settlement of macrofouling and the dimethylhexadecylammonium-based coatings provided protection against slime in comparison with PVC blank panels. Thus, results from laboratory assays did not fully concur with the AF activity of the paints in the field trial.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-08
... gun blanks. The initial investigation resulted in a negative determination based on the findings that the subject firm did not shift the production of pins, bushings, gun blanks (or like or directly...
NASA Astrophysics Data System (ADS)
Candra, S.; Batan, I. M. L.; Berata, W.; Pramono, A. S.
2017-11-01
This paper presents the mathematical approach of minimum blank holder force to prevent wrinkling in deep drawing process of the cylindrical cup. Based on the maximum of minor-major strain ratio, the slab method was applied to determine the modeling of minimum variable blank holder force (VBHF) and it compared to FE simulation. The Tin steel sheet of T4-CA grade, with the thickness of 0.2 mm was used in this study. The modeling of minimum VBHF can be used as a simple reference to prevent wrinkling in deep drawing.
NASA Astrophysics Data System (ADS)
Dietrich, André; Nacke, Bernard
2018-05-01
With the induction heating technology, it is possible to heat up blanks for the press hardening process in 20 s or less. Furthermore, the dimension of an induction system is small and easy to control in comparison to conventional heating systems. To bring the induction heating technology to warm forming industry it is necessary to analyze the process under the view of induction. This paper investigates the edge- and end-effects of a batch heated blank. The results facilitate the later design of induction heating systems for the batch process.
Hartmann, Cornelia; Dosen, Strahinja; Amsuess, Sebastian; Farina, Dario
2015-09-01
Electrocutaneous stimulation is a promising approach to provide sensory feedback to amputees, and thus close the loop in upper limb prosthetic systems. However, the stimulation introduces artifacts in the recorded electromyographic (EMG) signals, which may be detrimental for the control of myoelectric prostheses. In this study, artifact blanking with three data segmentation approaches was investigated as a simple method to restore the performance of pattern recognition in prosthesis control (eight motions) when EMG signals are corrupted by stimulation artifacts. The methods were tested over a range of stimulation conditions and using four feature sets, comprising both time and frequency domain features. The results demonstrated that when stimulation artifacts were present, the classification performance improved with blanking in all tested conditions. In some cases, the classification performance with blanking was at the level of the benchmark (artifact-free data). The greatest pulse duration and frequency that allowed a full performance recovery were 400 μs and 150 Hz, respectively. These results show that artifact blanking can be used as a practical solution to eliminate the negative influence of the stimulation artifact on EMG pattern classification in a broad range of conditions, thus allowing to close the loop in myoelectric prostheses using electrotactile feedback.
NASA Astrophysics Data System (ADS)
Choi, Hong-seok; Ha, Se-yoon; Cha, Seung-hoon; kang, Chung-gil; Kim, Byung-min
2011-08-01
The hot stamping process has been used in the automotive industry to reduce the weight of the body-in-white and to increase passenger safety via improved crashworthiness. In this study, a new form die with a simple structure that can prevent defects such as wrinkle and fracture is proposed for the manufacture of hot stamped components. The wrinkling at the flange cannot be eliminated when using a conventional form die. It is known that the initiation of wrinkling is influenced by many factors such as the mechanical properties of the sheet material, geometry of the sheet and tool, and other process parameters, including the blank holding force (BHF) and the contact conditions. In this research, channel type indirect blank holder (CIBH) is introduced to replace general blank holder for manufacturing the hot stamped center pillar. First, we investigate the tension force acting on the blank according to the channel shapes. We determine the appropriate range by comparing the tension force with the upper and lower BHFs in a conventional stamping process. We then use FE-analysis to study the influence of the slope angle and corner radius of the channel on the formability. Finally, the center pillar is manufactured using the form die with the selected channel.
Magnetron sputtering for the production of EUV mask blanks
NASA Astrophysics Data System (ADS)
Kearney, Patrick; Ngai, Tat; Karumuri, Anil; Yum, Jung; Lee, Hojune; Gilmer, David; Vo, Tuan; Goodwin, Frank
2015-03-01
Ion Beam Deposition (IBD) has been the primary technique used to deposit EUV mask blanks since 1995 when it was discovered it could produce multilayers with few defects. Since that time the IBD technique has been extensively studied and improved and is finally approaching usable defectivities. But in the intervening years, the defectivity of magnetron sputtering has been greatly improved. This paper evaluates the suitability of a modern magnetron tool to produce EUV mask blanks and the ability to support HVM production. In particular we show that the reflectivity and uniformity of these tools are superior to current generation IBD tools, and that the magnetron tools can produce EUV films with defect densities comparable to recent best IBD tool performance. Magnetron tools also offer many advantages in manufacturability and tool throughput; however, challenges remain, including transitioning the magnetron tools from the wafer to mask formats. While work continues on quantifying the capability of magnetron sputtering to meet the mask blank demands of the industry, for the most part the remaining challenges do not require any fundamental improvements to existing technology. Based on the recent results and the data presented in this paper there is a clear indication that magnetron deposition should be considered for the future of EUV mask blank production.
Rahman, Mohammad Mahmudur; Brown, Richard J C; Kim, Ki-Hyun; Yoon, Hye-On; Phan, Nhu-Thuc
2013-01-01
In an effort to reduce the experimental bias involved in the analysis of gaseous elemental mercury (Hg(o)), the blank response from gold-coated adsorption tubes has been investigated using cold vapor atomic absorption spectrometry (CVAAS). Our study has been compared with our recent investigation on memory effect in a cold vapour atomic fluorescence spectrometry (CVAFS). The pattern of blank responses was quantified after loading different amounts of mercury and after different time intervals of 1, 14, and 45 days. In case of the one day interval, the result of five to six instant blank heating cycles confirmed successful liberation of mercury following the second and third blank heating cycles. The results of 14 or 45 days generally suggest that liberation of excess mercury is affected by both the initial loading amount and the length of storage time prior to analysis. We have demonstrated a possibly effective way to reduce memory effects. Some similarities of these results with those from CVAFS experiment suggests that the blank response is caused by a combination of mercury absorbed within the bulk gold and micro- and nanoparticles liberated during heating and not from coabsorbing interfering gaseous species.
Rahman, Mohammad Mahmudur; Brown, Richard J. C.; Yoon, Hye-On; Phan, Nhu-Thuc
2013-01-01
In an effort to reduce the experimental bias involved in the analysis of gaseous elemental mercury (Hgo), the blank response from gold-coated adsorption tubes has been investigated using cold vapor atomic absorption spectrometry (CVAAS). Our study has been compared with our recent investigation on memory effect in a cold vapour atomic fluorescence spectrometry (CVAFS). The pattern of blank responses was quantified after loading different amounts of mercury and after different time intervals of 1, 14, and 45 days. In case of the one day interval, the result of five to six instant blank heating cycles confirmed successful liberation of mercury following the second and third blank heating cycles. The results of 14 or 45 days generally suggest that liberation of excess mercury is affected by both the initial loading amount and the length of storage time prior to analysis. We have demonstrated a possibly effective way to reduce memory effects. Some similarities of these results with those from CVAFS experiment suggests that the blank response is caused by a combination of mercury absorbed within the bulk gold and micro- and nanoparticles liberated during heating and not from coabsorbing interfering gaseous species. PMID:23589708
Influence of prepreg characteristics on stamp consolidation
NASA Astrophysics Data System (ADS)
Slange, T. K.; Warnet, L. L.; Grouve, W. J. B.; Akkerman, R.
2017-10-01
Stamp forming is a rapid manufacturing technology used to shape flat blanks of thermoplastic composite material into three-dimensional components. The development of automated lay-up technologies further extends the applicability of stamp forming by allowing rapid lay-up of tailored blanks and partial preconsolidation. This partial preconsolidation makes the influence of prepreg more critical compared to conventional preconsolidation methods which provide full preconsolidation. This paper aims to highlight consolidation challenges that can appear when stamp forming blanks manufactured by automated lay-up. Important prepreg characteristics were identified based on an experimental study where a comparison was made between various prepreg in their as-received, deconsolidated and stamp consolidated state. It was found that adding up small thickness variations across the width of a prepreg when stacking plies into a blank by automated lay-up can cause non-uniform consolidation. Additionally, deconsolidation of the prepreg does not seem to obstruct interlaminar bonding, while intralaminar voids initially present in a prepreg cannot be removed during stamp forming. An additional preconsolidation step after automated lay-up seems necessary to remove blank thickness variations and intralaminar voids for the current prepregs. Eliminating this process step and the successful combination of rapid automated lay-up and stamp forming requires prepregs which are void-free and have less thickness variation.
Development of Methods and Equipment for Sheet Stamping
NASA Astrophysics Data System (ADS)
Botashev, A. Yu; Bisilov, N. U.; Malsugenov, R. S.
2018-03-01
New methods of sheet stamping were developed: the gas forming with double-sided heating of a blank part and the gas molding with backpressure. In case of the first method the blank part is heated to the set temperature by means of a double-sided impact of combustion products of gas mixtures, after which, under the influence of gas pressure a stamping process is performed. In case of gas molding with backpressure, the blank part is heated to the set temperature by one-sided impact of the combustion products, while backpressure is created on the opposite side of the blank part by compressed air. In both methods the deformation takes place in the temperature range of warm or hot treatment due to the heating of a blank part. This allows one to form parts of complicated shape within one technological operation, which significantly reduces the cost of production. To implement these methods, original devices were designed and produced, which are new types of forging and stamping equipment. Using these devices, an experimental research on the stamping process was carried out and high-quality parts were obtained, which makes it possible to recommend the developed methods of stamping in the industrial production. Their application in small-scale production will allow one to reduce the cost price of stamped parts 2 or 3 times.
Computer Aided Process Planning for Non-Axisymmetric Deep Drawing Products
NASA Astrophysics Data System (ADS)
Park, Dong Hwan; Yarlagadda, Prasad K. D. V.
2004-06-01
In general, deep drawing products have various cross-section shapes such as cylindrical, rectangular and non-axisymmetric shapes. The application of the surface area calculation to non-axisymmetric deep drawing process has not been published yet. In this research, a surface area calculation for non-axisymmetric deep drawing products with elliptical shape was constructed for a design of blank shape of deep drawing products by using an AutoLISP function of AutoCAD software. A computer-aided process planning (CAPP) system for rotationally symmetric deep drawing products has been developed. However, the application of the system to non-axisymmetric components has not been reported yet. Thus, the CAPP system for non-axisymmetric deep drawing products with elliptical shape was constructed by using process sequence design. The system developed in this work consists of four modules. The first is recognition of shape module to recognize non-axisymmetric products. The second is a three-dimensional (3-D) modeling module to calculate the surface area for non-axisymmetric products. The third is a blank design module to create an oval-shaped blank with the identical surface area. The forth is a process planning module based on the production rules that play the best important role in an expert system for manufacturing. The production rules are generated and upgraded by interviewing field engineers. Especially, the drawing coefficient, the punch and die radii for elliptical shape products are considered as main design parameters. The suitability of this system was verified by applying to a real deep drawing product. This CAPP system constructed would be very useful to reduce lead-time for manufacturing and improve an accuracy of products.
ULE design considerations for a 3m class light weighted mirror blank for E-ELT M5
NASA Astrophysics Data System (ADS)
Fox, Andrew; Hobbs, Tom; Edwards, Mary; Arnold, Matthew; Sawyer, Kent
2016-07-01
It is expected that the next generation of large ground based astronomical telescopes will need large fast-steering/tip-tilt mirrors made of ultra-lightweight construction. These fast-steering mirrors are used to continuously correct for atmospheric disturbances and telescope vibrations. An example of this is the European Extremely Large Telescope (E-ELT) M5 lightweight mirror, which is part of the Tip-Tilt/Field-Stabilization Unit. The baseline design for the E-ELT M5 mirror, as presented in the E-ELT Construction Proposal, is a closed-back ULE mirror with a lightweight core using square core cells. Corning Incorporated (Corning) has a long history of manufacturing lightweight mirror blanks using ULE in a closed-back construction, going back to the 1960's, and includes the Hubble Space Telescope primary mirror, Subaru Telescope secondary and tertiary mirrors, the Magellan I and II tertiary mirrors, and Kepler Space Telescope primary mirror, among many others. A parametric study of 1-meter class lightweight mirror designs showed that Corning's capability to seal a continuous back sheet to a light-weighted core structure provides superior mirror rigidity, in a near-zero thermal expansion material, relative to other existing technologies in this design space. Corning has investigated the parametric performance of several design characteristics for a 3-meter class lightweight mirror blank for the E-ELT M5. Finite Element Analysis was performed on several design scenarios to obtain weight, areal density, and first Eigen frequency. This paper presents an overview of Corning ULE and lightweight mirror manufacturing capabilities, the parametric performance of design characteristics for 1-meter class and 3-meter class lightweight mirrors, as well as the manufacturing advantages and disadvantages of those characteristics.
Inorganic chemical analysis of environmental materials—A lecture series
Crock, J.G.; Lamothe, P.J.
2011-01-01
At the request of the faculty of the Colorado School of Mines, Golden, Colorado, the authors prepared and presented a lecture series to the students of a graduate level advanced instrumental analysis class. The slides and text presented in this report are a compilation and condensation of this series of lectures. The purpose of this report is to present the slides and notes and to emphasize the thought processes that should be used by a scientist submitting samples for analyses in order to procure analytical data to answer a research question. First and foremost, the analytical data generated can be no better than the samples submitted. The questions to be answered must first be well defined and the appropriate samples collected from the population that will answer the question. The proper methods of analysis, including proper sample preparation and digestion techniques, must then be applied. Care must be taken to achieve the required limits of detection of the critical analytes to yield detectable analyte concentration (above "action" levels) for the majority of the study's samples and to address what portion of those analytes answer the research question-total or partial concentrations. To guarantee a robust analytical result that answers the research question(s), a well-defined quality assurance and quality control (QA/QC) plan must be employed. This QA/QC plan must include the collection and analysis of field and laboratory blanks, sample duplicates, and matrix-matched standard reference materials (SRMs). The proper SRMs may include in-house materials and/or a selection of widely available commercial materials. A discussion of the preparation and applicability of in-house reference materials is also presented. Only when all these analytical issues are sufficiently addressed can the research questions be answered with known certainty.
Davis, Linda C.; Bartholomay, Roy C.; Rattray, Gordon W.
2013-01-01
Since 1952, wastewater discharged to infiltration ponds (also called percolation ponds) and disposal wells at the Idaho National Laboratory (INL) has affected water quality in the eastern Snake River Plain (ESRP) aquifer and perched groundwater zones underlying the INL. The U.S. Geological Survey (USGS), in cooperation with the U.S. Department of Energy, maintains groundwater monitoring networks at the INL to determine hydrologic trends, and to delineate the movement of radiochemical and chemical wastes in the aquifer and in perched groundwater zones. This report presents an analysis of water-level and water-quality data collected from aquifer, multilevel monitoring system (MLMS), and perched groundwater wells in the USGS groundwater monitoring networks during 2009–11. Water in the ESRP aquifer primarily moves through fractures and interflow zones in basalt, generally flows southwestward, and eventually discharges at springs along the Snake River. The aquifer primarily is recharged from infiltration of irrigation water, infiltration of streamflow, groundwater inflow from adjoining mountain drainage basins, and infiltration of precipitation. From March–May 2009 to March–May 2011, water levels in wells generally declined in the northern part of the INL. Water levels generally rose in the central and eastern parts of the INL. Detectable concentrations of radiochemical constituents in water samples from aquifer wells or MLMS equipped wells in the ESRP aquifer at the INL generally decreased or remained constant during 2009–11. Decreases in concentrations were attributed to radioactive decay, changes in waste-disposal methods, and dilution from recharge and underflow. In 2011, concentrations of tritium in groundwater from 50 of 127 aquifer wells were greater than or equal to the reporting level and ranged from 200±60 to 7,000±260 picocuries per liter. Tritium concentrations from one or more discrete zones from four wells equipped with MLMS were greater than or equal to reporting levels in water samples collected at various depths. Tritium concentrations in water from wells completed in shallow perched groundwater at the Advanced Test Reactor Complex (ATR Complex) were less than the reporting levels. Tritium concentrations in deep perched groundwater at the ATR Complex equaled or exceeded the reporting level in 12 wells during at least one sampling event during 2009–11 at the ATR Complex. Concentrations of strontium-90 in water from 20 of 76 aquifer wells sampled during April or October 2011 exceeded the reporting level. Strontium-90 was not detected within the ESRP aquifer beneath the ATR Complex. During at least one sampling event during 2009–11, concentrations of strontium-90 in water from 10 wells completed in deep perched groundwater at the ATR Complex equaled or exceeded the reporting levels. During 2009–11, concentrations of plutonium-238, and plutonium-239, -240 (undivided), and americium-241 were less than the reporting level in water samples from all aquifer wells and in all wells equipped with MLMS. Concentrations of cesium-137 were equal to or slightly above the reporting level in 8 aquifer wells and from 2 wells equipped with MLMS. The concentration of chromium in water from one well south of the ATR Complex was 97 micrograms per liter (μg/L) in April 2011, just less than the maximum contaminant level (MCL) of 100 μg/L. Concentrations of chromium in water samples from 69 other wells sampled ranged from 0.8 μg/L to 25 μg/L. During 2009–11, dissolved chromium was detected in water from 15 wells completed in perched groundwater at the ATR Complex. In 2011, concentrations of sodium in water from most wells in the southern part of the INL were greater than the background concentration of 10 milligrams per liter (mg/L); the highest concentrations were at or near the Idaho Nuclear Engineering and Technology Center (INTEC). After the newpercolation ponds were put into service in 2002 southwest of the INTEC, concentrations of sodium in water samples from the Rifle Range well rose steadily until 2008, when the concentrations generally began decreasing. The increases and decreases were attributed to disposal variability in the new percolation ponds. Concentrations of sodium in most wells equipped with MLMS generally were consistent with depth. During 2011, dissolved sodium concentrations in water from 17 wells completed in deep perched groundwater at the ATR Complex ranged from 6 to 146 mg/L. In 2011, concentrations of chloride in most water samples from aquifer wells south of the INTEC and at the Central Facilities Area exceeded the background concentrations of 15 mg/L, but were less than the secondary MCL of 250 mg/L. Chloride concentrations in water from wells south of the INTEC have generally increased because of increased chloride disposal to the old percolation ponds since 1984 when discharge of wastewater to the INTEC disposal well was discontinued. After the new percolation ponds were put into service in 2002 southwest of the INTEC, concentrations of chloride in water samples from one well rose steadily until 2008 then began decreasing. Chloride concentrations in water from all but one well completed in the ESRP aquifer at or near the ATR Complex were less than background and ranged between 10 and 14 mg/L during 2011, similar to concentrations detected during the 2006–08 reporting period. During 2011, chloride concentrations in water from two aquifer wells at the Radioactive Waste Management Complex (RWMC) were slightly greater than concentrations detected during the 2006–08 reporting period. The vertical distribution of chloride concentrations in wells equipped with MLMS were generally consistent within zones during 2009–11 and ranged from about 8 to 20 mg/L. During April 2011, dissolved chloride concentrations in shallow perched groundwater at the ATR Complex ranged from 7 to 13 mg/L in water from three wells. Dissolved chloride concentrations in deep perched groundwater at the ATR Complex during 2011 ranged from 4 to 54 mg/L. In 2011, sulfate concentrations in water samples from 11 aquifer wells in the south-central part of the INL equaled or exceeded the background concentration of sulfate and ranged from 40 to 167 mg/L. The greater-than-background concentrations in water from these wells probably resulted from sulfate disposal at the ATR Complex infiltration ponds or the old INTEC percolation ponds. In 2011, sulfate concentrations in water samples from two wells near the RWMC were greater than background levels and could have resulted from well construction techniques and (or) waste disposal at the RWMC. The vertical distribution of sulfate concentrations in three wells near the southern boundary of the INL was generally consistent with depth, and ranged between 19 and 25 mg/L. The maximum dissolved sulfate concentration in shallow perched groundwater near the ATR Complex was 400 mg/L in well CWP 1 in April 2011. During 2009–11, the maximum concentration of dissolved sulfate in deep perched groundwater at the ATR Complex was 1,550 mg/L in a well located west of the chemical-waste pond. In 2011, concentrations of nitrate in water from most wells at and near the INTEC exceeded the regional background concentrations of 1 mg/L and ranged from 1.6 to 5.95 mg/L. Concentrations of nitrate in wells south of INTEC and farther away from the influence of disposal areas and the Big Lost River show a general decrease in nitrate concentrations through time. During 2009–11, water samples from 30 wells were collected and analyzed for volatile organic compounds (VOCs). Six VOCs were detected. At least one and up to five VOCs were detected in water samples from 10 wells. The primary VOCs detected include carbon tetrachloride, chloroform, tetrachloroethylene, 1,1,1-trichloroethane, and trichloroethylene. In 2011, concentrations for all VOCs were less than their respective MCL for drinking water, except carbon tetrachloride in water from two wells. During 2009–11, variability and bias were evaluated from 56 replicate and 16 blank quality-assurance samples. Results from replicate analyses were investigated to evaluate sample variability. Constituents with acceptable reproducibility were stable isotope ratios, major ions, nutrients, and VOCs. All radiochemical constituents and trace metals had acceptable reproducibility except for gross beta-particle radioactivity, aluminum, antimony, and cobalt. Bias from sample contamination was evaluated from equipment, field, container, and source-solution blanks. No detectable constituent concentrations were reported for equipment blanks of the thief samplers and sampling pipes or for the source-solution and field blanks. Equipment blanks of bailers had detectable concentrations of strontium-90, sodium, chloride, and sulfate, and the container blank had a detectable concentration of dichloromethane.
1985-06-28
1984 to April 1985 includedr installation of 27 raw mnitor wells and 11 amh l’,(1 zjit~s, collecticn cf seive~t, sarples ftw surfac , soil, shallowv...modifying a sampling and analytical program that addresses the requirements of the project. If project requirements necessitate different quality...reagent blank and at least five (5) different concentrations of thl analyte. A modification of the method of Hubaux and Vos will be used to deter
DMSP Special Sensor Microwave/Imager Calibration/Validation. Volume 1
1990-01-01
each channel samples the hot load on every scan and commands a gain change up when the hot load is below 7/16th of the analog to digital converter range...OLS imagery. A threshold blanking technique was used to convert the manual analyses into synthetic digital images containing the cloud truth...should include OLS digital thermal infrared into the analysis. While this will be of use only in clear, relatively dry atmospheric conditions, the
Reappraisal of hydrocarbon biomarkers in Archean rocks
French, Katherine L.; Hallmann, Christian; Hope, Janet M.; Schoon, Petra L.; Zumberge, J. Alex; Hoshino, Yosuke; Peters, Carl A.; George, Simon C.; Love, Gordon D.; Brocks, Jochen J.; Buick, Roger; Summons, Roger E.
2015-01-01
Hopanes and steranes found in Archean rocks have been presented as key evidence supporting the early rise of oxygenic photosynthesis and eukaryotes, but the syngeneity of these hydrocarbon biomarkers is controversial. To resolve this debate, we performed a multilaboratory study of new cores from the Pilbara Craton, Australia, that were drilled and sampled using unprecedented hydrocarbon-clean protocols. Hopanes and steranes in rock extracts and hydropyrolysates from these new cores were typically at or below our femtogram detection limit, but when they were detectable, they had total hopane (<37.9 pg per gram of rock) and total sterane (<32.9 pg per gram of rock) concentrations comparable to those measured in blanks and negative control samples. In contrast, hopanes and steranes measured in the exteriors of conventionally drilled and curated rocks of stratigraphic equivalence reach concentrations of 389.5 pg per gram of rock and 1,039 pg per gram of rock, respectively. Polycyclic aromatic hydrocarbons and diamondoids, which exceed blank concentrations, exhibit individual concentrations up to 80 ng per gram of rock in rock extracts and up to 1,000 ng per gram of rock in hydropyrolysates from the ultraclean cores. These results demonstrate that previously studied Archean samples host mixtures of biomarker contaminants and indigenous overmature hydrocarbons. Therefore, existing lipid biomarker evidence cannot be invoked to support the emergence of oxygenic photosynthesis and eukaryotes by ∼2.7 billion years ago. Although suitable Proterozoic rocks exist, no currently known Archean strata lie within the appropriate thermal maturity window for syngenetic hydrocarbon biomarker preservation, so future exploration for Archean biomarkers should screen for rocks with milder thermal histories. PMID:25918387
NASA Astrophysics Data System (ADS)
Mao, Chun; Zhang, Can; Qiu, Yongzhi; Zhu, Aiping; Shen, Jian; Lin, Sicong
2004-04-01
Based on in vitro tests for an improvement of the blood compatibility of polypropylene (PP) films by grafting O-butyrylchitosan (OBCS), we prepared a novel biocompatible film. The immobilization was accomplished by irradiating with ultraviolet light, OBCS being coated on the film surface to photolyze azide groups, thus cross-linking OBCS and PP together. The grafted sample films were verified by attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR), electron spectroscopy for chemical analysis (ESCA) and the water contact angle measurements. The blood compatibility of the OBCS-grafted PP films was evaluated by platelet rich plasma (PRP) contacting experiments and protein adsorption experiments using blank PP film as the control. It demonstrated that blood compatibility of the OBCS-grafted surfaces is better than that of the blank PP. The suitable modifications could be carried out to tailor PP biomaterial to meet the specific needs of different biomedical applications. These results suggest that the photocrosslinkable chitosan developed here has the potential of serving as a new biomaterial in medical use.
Blonigen, Daniel M.; Patrick, Christopher J.; Gasperi, Marianna; Steffen, Benjamin; Ones, Deniz S.; Arvey, Richard D.; de Oliveira Baumgartl, Viviane; do Nascimento, Elizabeth
2010-01-01
Integrity testing has long been utilized in personnel selection to screen for tendencies toward counterproductive workplace behaviors. The construct of externalizing from the psychopathology literature represents a coherent spectrum marked by disinhibitory traits and behaviors. The present study used a sample of male and female undergraduates to examine the construct network of the Personnel Reaction Blank (PRB; Gough, Arvey, & Bradley, 2004), a measure of integrity, in relation to externalizing as well as normal-range personality constructs assessed by the Multidimensional Personality Questionnaire (MPQ; Tellegen & Waller, 2008). Results revealed moderate to strong associations between several PRB scales and externalizing, which were largely accounted for by MPQ traits subsumed by Negative Emotionality and Constraint. After accounting for MPQ traits in the prediction of externalizing, a modest predictive increment was achieved when adding the PRB scales, particularly biographical indicators from the Prosocial Background subscale. The findings highlight externalizing as a focal criterion for scale development in the integrity testing literature, and help delineate the construct network of the PRB within the domains of personality and psychopathology. PMID:21171783
Hardy, M.A.; Leahy, P.P.; Alley, W.M.
1989-01-01
Several pilot projects are being conducted as part of the National Water Quality Assessment (NAWQA) Program. The purpose of the pilot program is to test and refine concepts for a proposed full-scale program. Three of the pilot projects are specifically designed to assess groundwater. The purpose of this report is to describe the criteria that are being used in the NAWQA pilot projects for selecting and documenting wells, installing new wells, and sampling wells for different water quality constituents. Guidelines are presented for the selection of wells for sampling. Information needed to accurately document each well includes site characteristics related to the location of the well, land use near the well, and important well construction features. These guidelines ensure the consistency of the information collected and will provide comparable data for interpretive purposes. Guidelines for the installation of wells are presented and include procedures that need to be followed for preparations prior to drilling, the selection of the drilling technique and casing type, the grouting procedure, and the well-development technique. A major component of the protocols is related to water quality sampling. Tasks are identified that need to be completed prior to visiting the site for sampling. Guidelines are presented for purging the well prior t sampling, both in terms of the volume of water pumped and the chemical stability of field parameters. Guidelines are presented concerning sampler selection as related to both inorganic and organic constituents. Documentation needed to describe the measurements and observations related to sampling each well and treating and preserving the samples are also presented. Procedures are presented for the storage and shipping of water samples, equipment cleaning, and quality assurance. Quality assurance guidelines include the description of the general distribution of the various quality assurance samples (blanks, spikes, duplicates, and reference samples) that will be used in the pilot program. (Lantz-PTT)
NASA Technical Reports Server (NTRS)
Gelman, B. G.; Drozdov, Y. V.; Melnikov, V. V.; Rotin, V. A.; Khokhlov, V. N.; Bondarev, V. B.; Dolnikov, G. G.; Dyachkov, A. V.; Nenarokov, D. F.; Mukhin, L. M.
1986-01-01
The experiment on sulfuric acid aerosol determination in the Venusian cloud layer on board the Vega landers is described. An average content of sulfuric acid of approximately 1 mg/cu m was found for the samples taken from the atmosphere at heights from 63 to 48 km and analyzed with the SIGMA-3 chromatograph. Sulfur dioxide (SO2) was revealed in the gaseous sample at the height of 48 km. From the experimental results and blank run measurements, a suggestion is made that the Venusian cloud layer aerosol consists of more complicated particles than the sulfuric acid water solution does.
Surface and catalytic properties of acid metal carbons prepared by the sol gel method
NASA Astrophysics Data System (ADS)
Aguado-Serrano, J.; Rojas-Cervantes, M. L.; Martín-Aranda, R. M.; López-Peinado, A. J.; Gómez-Serrano, V.
2006-06-01
The sol-gel method has been applied for the synthesis of a series of acid metal-carbon xerogels (with M = V, Cr, Mo and Ni) by polymerisation of resorcinol with formaldehyde in the presence of metallic precursors. A blank sample was also prepared without any metal addition. The xerogels were heated in nitrogen at 1000 °C to obtain the pyrolysed products. The samples were characterised by different techniques such as thermal-mass spectrometry analysis, gas physisorption, and mercury porosimetry. In addition, the acid character of the pyrolysed products was tested by the Claisen-Schmidt condensation between benzaldehyde and acetophenone for the formation of chalcones.
Application of microwave digestion to the analysis of peat
Papp, C.S.E.; Fischer, L.B.
1987-01-01
A microwave digestion technique for the dissolution of peat is described and compared with a dry ashing method and a nitric - perchloric - hydrofluoric acid wet digestion. Peat samples with different organic matter contents were used and Ca, Mg, Fe, AI, Na, K, Mn, Zn, Cu and Li were determined by atomic absoprtion spectrometry. The results obtained using the three dissolution techniques were in good agreement. The microwave method has the advantage of digesting the samples in less than 2 h and uses less acid than the conventional wet digestion method. Keeping the volume of the acid mixture as small as possible minimises contamination and leads to lower blank values.
NASA Astrophysics Data System (ADS)
Zadpoor, Amir Abbas; Sinke, Jos
2011-01-01
Friction stir welding is a solid state joining process with relatively low welding temperatures. Nevertheless, the mechanical properties of friction stir welded blanks are degraded after welding. Indeed, both strength and ductility of the welds are decreased after welding. Often, the resulting friction stir welded blanks need to be formed to their final structural shape. Therefore, the formability of friction stir welded blanks is of primary importance in the manufacturing of structural parts. This paper studies how the mechanical properties and particularly formability of friction stir welded blanks can be improved by applying a post weld heat treatment. Two aluminum alloys from 2000 and 7000 series, namely 2024-T3 and 7075-T6, are selected for the study. The sheet thickness of both materials is 2,0 mm. The selected alloys are welded in three configurations: 2024-T3 and 2024-T3, 7075-T6 and 7075-T6, and 2024-T3 and 7075-T6. The resulting welds are naturally aged for a few months. Three sets of standard dog bone shape tensile test specimens are then machined from the welds. The first set of the specimens is tested without any heat treatment. The second set of the specimens is solution heat treated and quenched before testing. The third set of the specimens is solution heat treated, quenched, and naturally aged for a week before testing. The mechanical properties of the three different sets of specimens are compared with each other. It is shown that careful selection of post weld heat-treatment can greatly improve the formability of friction stir welded blanks.
Effects of process variation in short cycle stretch forming in beverage can production
NASA Astrophysics Data System (ADS)
Schneider, Matthias; Liewald, Mathias
2016-10-01
Short Cycle Stretch Forming (SCS) is an innovative stretch forming technology developed at the Institute for Metal Forming Technology (IFU) at the University of Stuttgart. The SCS technology combines plane pre-stretching and deep drawing operations within the same stroke of press ram. Material is yielding from the inner to the outer part of the sheet. The sheet thickness is reduced and denting resistance and yield stress are increased due to hardening effects. SCS-Technology is enhanced due to rotational-symmetrical bodies by applying this technology to a cupping process in tinplate can production. A process simulation for SCS-Cupping processes was conducted. Based on these results a tool was manufactured and commissioned. Experimental results showed that material yields from the middle of the blank to the outer area of the cup wall. Due to the volume of material, the initial diameter can be reduced and material costs can be saved. In this paper different process settings and their effect on the amount of material, which yielded from the middle of the blank to its outside, are observed in a number of experimental series. A blank holder is added to the process in order to avoid wrinkling. The influence of this additional blank holder is therefore investigated in a first experimental set-up by varying blank holder force. In a further investigation the effects of two materials with different thicknesses is observed. Finally, an experimental series is conducted to observe the effect of blank diameter on the SCS-Cupping process. The results of this paper show that SCS-Cupping offers a promising potential for material savings and outline main effects for this technology.
Currie, L A
2001-07-01
Three general classes of skewed data distributions have been encountered in research on background radiation, chemical and radiochemical blanks, and low levels of 85Kr and 14C in the atmosphere and the cryosphere. The first class of skewed data can be considered to be theoretically, or fundamentally skewed. It is typified by the exponential distribution of inter-arrival times for nuclear counting events for a Poisson process. As part of a study of the nature of low-level (anti-coincidence) Geiger-Muller counter background radiation, tests were performed on the Poisson distribution of counts, the uniform distribution of arrival times, and the exponential distribution of inter-arrival times. The real laboratory system, of course, failed the (inter-arrival time) test--for very interesting reasons, linked to the physics of the measurement process. The second, computationally skewed, class relates to skewness induced by non-linear transformations. It is illustrated by non-linear concentration estimates from inverse calibration, and bivariate blank corrections for low-level 14C-12C aerosol data that led to highly asymmetric uncertainty intervals for the biomass carbon contribution to urban "soot". The third, environmentally, skewed, data class relates to a universal problem for the detection of excursions above blank or baseline levels: namely, the widespread occurrence of ab-normal distributions of environmental and laboratory blanks. This is illustrated by the search for fundamental factors that lurk behind skewed frequency distributions of sulfur laboratory blanks and 85Kr environmental baselines, and the application of robust statistical procedures for reliable detection decisions in the face of skewed isotopic carbon procedural blanks with few degrees of freedom.
Shelton, Jennifer L.; Fram, Miranda S.; Munday, Cathy M.; Belitz, Kenneth
2010-01-01
Groundwater quality in the approximately 25,500-square-mile Sierra Nevada study unit was investigated in June through October 2008, as part of the Priority Basin Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin Project is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The Sierra Nevada study was designed to provide statistically robust assessments of untreated groundwater quality within the primary aquifer systems in the study unit, and to facilitate statistically consistent comparisons of groundwater quality throughout California. The primary aquifer systems (hereinafter, primary aquifers) are defined by the depth of the screened or open intervals of the wells listed in the California Department of Public Health (CDPH) database of wells used for public and community drinking-water supplies. The quality of groundwater in shallower or deeper water-bearing zones may differ from that in the primary aquifers; shallow groundwater may be more vulnerable to contamination from the surface. In the Sierra Nevada study unit, groundwater samples were collected from 84 wells (and springs) in Lassen, Plumas, Butte, Sierra, Yuba, Nevada, Placer, El Dorado, Amador, Alpine, Calaveras, Tuolumne, Madera, Mariposa, Fresno, Inyo, Tulare, and Kern Counties. The wells were selected on two overlapping networks by using a spatially-distributed, randomized, grid-based approach. The primary grid-well network consisted of 30 wells, one well per grid cell in the study unit, and was designed to provide statistical representation of groundwater quality throughout the entire study unit. The lithologic grid-well network is a secondary grid that consisted of the wells in the primary grid-well network plus 53 additional wells and was designed to provide statistical representation of groundwater quality in each of the four major lithologic units in the Sierra Nevada study unit: granitic, metamorphic, sedimentary, and volcanic rocks. One natural spring that is not used for drinking water was sampled for comparison with a nearby primary grid well in the same cell. Groundwater samples were analyzed for organic constituents (volatile organic compounds [VOC], pesticides and pesticide degradates, and pharmaceutical compounds), constituents of special interest (N-nitrosodimethylamine [NDMA] and perchlorate), naturally occurring inorganic constituents (nutrients, major ions, total dissolved solids, and trace elements), and radioactive constituents (radium isotopes, radon-222, gross alpha and gross beta particle activities, and uranium isotopes). Naturally occurring isotopes and geochemical tracers (stable isotopes of hydrogen and oxygen in water, stable isotopes of carbon, carbon-14, strontium isotopes, and tritium), and dissolved noble gases also were measured to help identify the sources and ages of the sampled groundwater. Three types of quality-control samples (blanks, replicates, and samples for matrix spikes) each were collected at approximately 10 percent of the wells sampled for each analysis, and the results for these samples were used to evaluate the quality of the data for the groundwater samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that contamination from sample collection, handling, and analytical procedures was not a significant source of bias in the data for the groundwater samples. Differences between replicate samples were within acceptable ranges, with few exceptions. Matrix-spike recoveries were within acceptable ranges for most compounds. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, groundwater typically is treated, disinfected, or blended with other waters to maintain water quality. Regulatory benchmarks apply to finished drinking water that is served to the consumer, not to untre
Rosenberg, Matthew B; Dockery, Christopher R
2008-11-01
Laser-induced breakdown spectroscopy (LIBS) has been used to determine the period of time that a shooter will test positive for gunshot residue (GSR) after firing a revolver. Multiple rounds of primer were fired and samples collected at multiple hour intervals using an adhesive tape pressed against the skin. Samples were analyzed directly using a commercially available laser-induced breakdown spectrometer where barium emission (originating from barium nitrate in the primer) was observed. Population statistics were used to compare suspected GSR to a library of blank samples from which a threshold value was established. Statistically significant results, positive for GSR, are obtained 5.27 days after a firearm discharge using these techniques.
Adjustable extender for instrument module
Sevec, J.B.; Stein, A.D.
1975-11-01
A blank extender module used to mount an instrument module in front of its console for repair or test purposes has been equipped with a rotatable mount and means for locking the mount at various angles of rotation for easy accessibility. The rotatable mount includes a horizontal conduit supported by bearings within the blank module. The conduit is spring-biased in a retracted position within the blank module and in this position a small gear mounted on the conduit periphery is locked by a fixed pawl. The conduit and instrument mount can be pulled into an extended position with the gear clearing the pawl to permit rotation and adjustment of the instrument.
Method for making devices having intermetallic structures and intermetallic devices made thereby
Paul, Brian Kevin; Wilson, Richard Dean; Alman, David Eli
2004-01-06
A method and system for making a monolithic intermetallic structure are presented. The structure is made from lamina blanks which comprise multiple layers of metals which are patternable, or intermetallic lamina blanks that are patternable. Lamina blanks are patterned, stacked and registered, and processed to form a monolithic intermetallic structure. The advantages of a patterned monolithic intermetallic structure include physical characteristics such as melting temperature, thermal conductivity, and corrosion resistance. Applications are broad, and include among others, use as a microreactor, heat recycling device, and apparatus for producing superheated steam. Monolithic intermetallic structures may contain one or more catalysts within the internal features.
Development and Piloting of the Prosocial Attitude Blank.
ERIC Educational Resources Information Center
Wasson, Rebecca; And Others
The Prosocial Attitude Blank (PAB) was designed to assess interpersonal values and ethical awareness of elementary school children. PAB was administered to 405 elementary students as one component of the evaluation of an intervention program designed to reduce interpersonal conflicts, increase literacy skills, and enhance children's ethical…
Social Impacts Module (SIM) Transition
2012-09-28
User String The authorized user’s name to access the PAVE database. Applies only to Microsoft SQL Server; leave blank, otherwise. passwd String The...otherwise. passwd String The password if an authorized user’s name is required; otherwise, leave blank driver String The class name for the driver to
NASA Astrophysics Data System (ADS)
Robertson, Brant E.; Ellis, Richard S.; Dunlop, James S.; McLure, Ross J.; Stark, Dan P.; McLeod, Derek
2014-12-01
Strong gravitational lensing provides a powerful means for studying faint galaxies in the distant universe. By magnifying the apparent brightness of background sources, massive clusters enable the detection of galaxies fainter than the usual sensitivity limit for blank fields. However, this gain in effective sensitivity comes at the cost of a reduced survey volume and, in this Letter, we demonstrate that there is an associated increase in the cosmic variance uncertainty. As an example, we show that the cosmic variance uncertainty of the high-redshift population viewed through the Hubble Space Telescope Frontier Field cluster Abell 2744 increases from ~35% at redshift z ~ 7 to >~ 65% at z ~ 10. Previous studies of high-redshift galaxies identified in the Frontier Fields have underestimated the cosmic variance uncertainty that will affect the ultimate constraints on both the faint-end slope of the high-redshift luminosity function and the cosmic star formation rate density, key goals of the Frontier Field program.
1987-12-01
HOLRS I TSTMS C/OR RAIN L/OR HAIL WITH FOG C/OR uLO6ING C/OR A/LBST TOIAL ULT) I ORIZILL C/OP SLEET PRECIP PAZE SNOb SAND 10 0bC I RZZLE VIS ION JA. LE...AISARTEITItS TO t MILES ANT) GREATER THAN L rALT S. T1-.LBOPE TI J-L LOEUMN FOB BICIbILI TIES F,;ijAL T0 OR GREATER THAN 1D MALLS APPEAl BLANK. AS A "EL
1988-03-01
AFP 59 SW-4 Production Field Blank Water Well Water Hart 004 Water Hart 005 f Hart 007 H.3-13 PRINCETON TESTING LABORATORYI 3v~ zANA -YS--S REDO:’- =I...observations. Enforcing the "buddy system" where appropriate. " Determining and posting locations and routes to medical facili- ties, including...poison control centers; arranging for emergency transportation to medical facilities. " Notifying local public emergency officers, i.e., police and fire
Ferrari, Matthew J.; Fram, Miranda S.; Belitz, Kenneth
2008-01-01
Ground-water quality in the approximately 950 square kilometer (370 square mile) Central Sierra study unit (CENSIE) was investigated in May 2006 as part of the Priority Basin Assessment project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin Assessment project was developed in response to the Ground-Water Quality Monitoring Act of 2001, and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). This study was designed to provide a spatially unbiased assessment of the quality of raw ground water used for drinking-water supplies within CENSIE, and to facilitate statistically consistent comparisons of ground-water quality throughout California. Samples were collected from thirty wells in Madera County. Twenty-seven of the wells were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study area (grid wells), and three were selected to aid in evaluation of specific water-quality issues (understanding wells). Ground-water samples were analyzed for a large number of synthetic organic constituents (volatile organic compounds [VOCs], gasoline oxygenates and degradates, pesticides and pesticide degradates), constituents of special interest (N-nitrosodimethylamine, perchlorate, and 1,2,3-trichloropropane), naturally occurring inorganic constituents [nutrients, major and minor ions, and trace elements], radioactive constituents, and microbial indicators. Naturally occurring isotopes [tritium, and carbon-14, and stable isotopes of hydrogen, oxygen, nitrogen, and carbon], and dissolved noble gases also were measured to help identify the sources and ages of the sampled ground water. In total, over 250 constituents and water-quality indicators were investigated. Quality-control samples (blanks, replicates, and samples for matrix spikes) were collected at approximately one-sixth of the wells, and the results for these samples were used to evaluate the quality of the data for the ground-water samples. Results from field blanks indicated contamination was not a noticeable source of bias in the data for ground-water samples. Differences between replicate samples were within acceptable ranges, indicating acceptably low variability. Matrix spike recoveries were within acceptable ranges for most constituents. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, water typically is treated, disinfected, or blended with other waters to maintain water quality. Regulatory thresholds apply to water that is served to the consumer, not to raw ground water. However, to provide some context for the results, concentrations of constituents measured in the raw ground water were compared with health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and California Department of Public Health (CDPH), and thresholds established for aesthetic concerns (Secondary Maximum Contaminant Levels, SMCL-CA) by CDPH. Therefore, any comparisons of the results of this study to drinking-water standards only is for illustrative purposes and is not indicative of compliance or non-compliance to those standards. Most constituents that were detected in ground-water samples were found at concentrations below drinking-water standards or thresholds. Six constituents? fluoride, arsenic, molybdenum, uranium, gross-alpha radioactivity, and radon-222?were detected at concentrations higher than thresholds set for health-based regulatory purposes. Three additional constituents?pH, iron and manganese?were detected at concentrations above thresholds set for aesthetic concerns. Volatile organic compounds (VOCs) and pesticides, were detected in less than one-third of the samples and generally at less than one one-hundredth of a health-based threshold.
Lowest cost due to highest productivity and highest quality
NASA Astrophysics Data System (ADS)
Wenk, Daniel
2003-03-01
Since global purchasing in the automotive industry has been taken up all around the world there is one main key factor that makes a TB-supplier today successful: Producing highest quality at lowest cost. The fact that Tailored Blanks, which today may reach up to 1/3 of a car body weight, are purchased on the free market but from different steel suppliers, especially in Europe and NAFTA, the philosophy on OEM side has been changing gradually towards tough evaluation criteria. "No risk at the stamping side" calls for top quality Tailored- or Tubular Blank products. Outsourcing Tailored Blanks has been starting in Japan but up to now without any quality request from the OEM side like ISO 13919-1B (welding quality standard in Europe and USA). Increased competition will automatically push the quality level and the ongoing approach to combine high strength steel with Tailored- and Tubular Blanks will ask for even more reliable system concepts which enables to weld narrow seams at highest speed. Beside producing quality, which is the key to reduce one of the most important cost driver "material scrap," in-line quality systems with true and reliable evaluation is going to be a "must" on all weld systems. Traceability of all process related data submitted to interfaces according to customer request in combination with ghost-shift-operation of TB systems are tomorrow's state-of-the-art solutions of Tailored Blank-facilities.
Inverse Analysis to Formability Design in a Deep Drawing Process
NASA Astrophysics Data System (ADS)
Buranathiti, Thaweepat; Cao, Jian
Deep drawing process is an important process adding values to flat sheet metals in many industries. An important concern in the design of a deep drawing process generally is formability. This paper aims to present the connection between formability and inverse analysis (IA), which is a systematical means for determining an optimal blank configuration for a deep drawing process. In this paper, IA is presented and explored by using a commercial finite element software package. A number of numerical studies on the effect of blank configurations to the quality of a part produced by a deep drawing process were conducted and analyzed. The quality of the drawing processes is numerically analyzed by using an explicit incremental nonlinear finite element code. The minimum distance between elemental principal strains and the strain-based forming limit curve (FLC) is defined as tearing margin to be the key performance index (KPI) implying the quality of the part. The initial blank configuration has shown that it plays a highly important role in the quality of the product via the deep drawing process. In addition, it is observed that if a blank configuration is not greatly deviated from the one obtained from IA, the blank can still result a good product. The strain history around the bottom fillet of the part is also observed. The paper concludes that IA is an important part of the design methodology for deep drawing processes.
Quartz 9-inch size mask blanks for ArF PSM (Phase Shift Mask)
NASA Astrophysics Data System (ADS)
Harashima, Noriyuki; Isozaki, Tatsuya; Kawanishi, Arata; Kanai, Shuichiro; Kageyama, Kagehiro; Iso, Hiroyuki; Chishima, Tatsuya
2017-07-01
Semiconductor technology nodes are steadily miniaturizing. On the other hand, various efforts have been made to reduce costs, mass production lines have shifted from 200 mmφ of Si wafer to 300 mmφ, and technology development of Si wafer 450 mmφ is also in progress. As a photomask, 6-inch size binary Cr mask has been used for many years, but in recent years, the use of 9-inch binary Cr masks for Proximity Lithography Process in automotive applications, MEMS, packages, etc. has increased, and cost reduction has been taken. Since the miniaturization will progress in the above applications in the future, products corresponding to miniaturization are also desired in 9-inch photomasks. The high grade Cr - binary mask blanks used in proximity exposure process, there is a prospect of being able to use it by ULVAC COATING CORPORATION's tireless research. As further demands for miniaturization, KrF and ArF Lithography Process, which are used for steppers and scanners , there are also a demand for 9-inch size Mask Blanks. In ULVAC COATING CORPORATION, we developed a 9 - inch size KrF PSM mask Blanks prototype in 2016 and proposed a new high grade 9 - inch photomask. This time, we have further investigated and developed 9-inch size ArF PSM Mask Blanks corresponding to ArF Lithography Process, so we report it.
Production of the 4.26 m ZERODUR mirror blank for the Advanced Technology Solar telescope (ATST)
NASA Astrophysics Data System (ADS)
Jedamzik, Ralf; Werner, Thomas; Westerhoff, Thomas
2014-07-01
The Daniel K. Inouye Solar Telescope (DKIST, formerly the Advanced Technology Solar Telescope, ATST) will be the most powerful solar telescope in the world. It is currently being built by the Association of Universities for Research in Astronomy (AURA) in a height of 3000 m above sea level on the mountain Haleakala of Maui, Hawaii. The primary mirror blank of diameter 4.26 m is made of the extremely low thermal expansion glass ceramic ZERODUR® of SCHOTT AG Advanced Optics. The DKIST primary mirror design is extremely challenging. With a mirror thickness of only 78 to 85 mm it is the smallest thickness ever machined on a mirror of 4.26 m in diameter. Additionally the glassy ZERODUR® casting is one of the largest in size ever produced for a 4 m class ZERODUR® mirror blank. The off axis aspherical mirror surface required sophisticated grinding procedures to achieve the specified geometrical tolerance. The small thickness of about 80 mm required special measures during processing, lifting and transport. Additionally acid etch treatment was applied to the convex back-surface and the conical shaped outer diameter surface to improve the strength of the blank. This paper reports on the challenging tasks and the achievements on the material property and dimensional specification parameter during the production of the 4.26 m ZERODUR® primary mirror blank for AURA.
Putnam, Larry D.; Hoogestraat, Galen K.; Sawyer, J. Foster
2008-01-01
Onsite wastewater disposal systems (OWDS) are used extensively in the Black Hills of South Dakota where many of the watersheds and aquifers are characterized by fractured or solution-enhanced bedrock with thin soil cover. A study was conducted during 2006-08 to characterize water-quality effects and indicators of OWDS. Water samples were collected and analyzed for potential indicators of OWDS, including chloride, bromide, boron, nitrite plus nitrate (NO2+NO3), ammonia, major ions, nutrients, selected trace elements, isotopes of nitrate, microbiological indicators, and organic wastewater compounds (OWCs). The microbiological indicators were fecal coliforms, Escherichia coli (E. coli), enterococci, Clostridium perfringens (C. perfringens), and coliphages. Sixty ground-water sampling sites were located either downgradient from areas of dense OWDS or in background areas and included 25 monitoring wells, 34 private wells, and 1 spring. Nine surface-water sampling sites were located on selected streams and tributaries either downstream or upstream from residential development within the Precambrian setting. Sampling results were grouped by their hydrogeologic setting: alluvial, Spearfish, Minnekahta, and Precambrian. Mean downgradient dissolved NO2+NO3 concentrations in ground water for the alluvial, Spearfish, Minnekahta, and Precambrian settings were 0.734, 7.90, 8.62, and 2.25 milligrams per liter (mg/L), respectively. Mean downgradient dissolved chloride concentrations in ground water for these settings were 324, 89.6, 498, and 33.2 mg/L, respectively. Mean downgradient dissolved boron concentrations in ground water for these settings were 736, 53, 64, and 43 micrograms per liter (ug/L), respectively. Mean dissolved surface-water concentrations for NO2+NO3, chloride, and boron for downstream sites were 0.222 mg/L, 32.1 mg/L, and 28 ug/L, respectively. Mean values of delta-15N and delta-18O (isotope ratios of 14N to 15N and 18O to 16O relative to standard ratios) for nitrate in ground-water samples were 10.4 and -2.0 per mil (0/100), respectively, indicating a relatively small contribution from synthetic fertilizer and probably a substantial contribution from OWDS. The surface-water sample with the highest dissolved NO2+NO3 concentration of 1.6 mg/L had a delta-15N value of 12.36 0/100, which indicates warm-blooded animals (including humans) as the nitrate source. Fecal coliforms were detected in downgradient ground water most frequently in the Spearfish (19 percent) and Minnekahta (9.7 percent) settings. E. coli was detected most frequently in the Minnekahta (29 percent) and Spearfish (13 percent) settings. Enterococci were detected more frequently than other microbiological indicators in all four settings. Fecal coliforms and E. coli were detected in 73 percent and 95 percent of all surface-water samples, respectively. Enterococci, coliphages (somatic), and C. perfringens were detected in 50, 70, and 50 percent of surface-water samples, respectively. Of the 62 OWC analytes, 12 were detected only in environmental samples, 10 were detected in at least one environmental and one blank sample (not necessarily companion pairs), 2 were detected only in blank samples, and 38 were not detected in any blank, environmental, or replicate sample from either ground or surface water. Eleven different organic compounds were detected in ground-water samples at eight different sites. The most frequently occurring compound was DEET, which was found in 32 percent of the environmental samples, followed by tetrachloroethene, which was detected in 20 percent of the samples. For surface-water samples, 16 organic compounds were detected in 9 of the 10 total samples. The compound with the highest occurrence in surface-water samples was camphor, which was detected in 50 percent of samples. The alluvial setting was characterized by relatively low dissolved NO2+NO3 concentrations, detection of ammonia nitrogen, and relatively high concentr
Communist China’s Progress in Inorganic, Organic, and Physical Chemistry in Recent Decade
1960-03-16
situation, develp t ms bin- dered. ?ollwving the revival of nastieal tahvoloe In World War I, Inorganic chemstry , lMke other branches of che•strj, mde seem...in high-density sam~ples." Looking back at the devolou t of our inorganic chemstry in the pest decadse, we believe that today’s echievemt from a blank...8217, and rich chemical resources are Iamting for. solutions, Therefore, Our Inorganic chemstry workers must bear in mind the development of Chinats
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gross, Cory Thomas
2008-01-01
The focus of this dissertation is the development of techniques with which to enhance the existing abilities of inductively coupled plasma mass spectrometry (ICP-MS). ICP-MS is a powerful technique for trace metal analysis in samples of many types, but like any technique it has certain strengths and weaknesses. Attempts are made to improve upon those strengths and to overcome certain weaknesses.
Iridescent Virus and Nosema ceranae Linked to Honeybee Colony Collapse Disorder
2010-12-01
recorded and exhibited several peaks and crashes until it declined by approximate geometric decay to extinction (Figure 2). Of the six RNA bee viruses...counts for all unique Iridovirus peptides in each sample. 19 Blank 20 LITERATURE CITED 1. Debnam, S . et al. Bee Culture 2008, 137, 30. 2. Higes...Pathol. 1978, 31, 368. 23. Verma, S . K. P. S . Phogat, Indian Bee J. 1982,44, 36. 24. Moore, N. F., Kelly, D. C. J. Invertebr. Pathol. 1980, 36,415
2012-09-01
relative performance of several conventional SQL and NoSQL databases with a set of one billion file block hashes. Digital Forensics, Sector Hashing, Full... NoSQL databases with a set of one billion file block hashes. v THIS PAGE INTENTIONALLY LEFT BLANK vi Table of Contents List of Acronyms and...Operating System NOOP No Operation assembly instruction NoSQL “Not only SQL” model for non-relational database management NSRL National Software
1992-01-01
Calculated by the Carbon Balance and by the C -V M ethod . ...................................... ... ... ... ... ... 6-8 x I I Table 6.3 EF for the...A-i APPENDIX B. SAMPLING AND DETERMINATION OF POLYCHLORINATED DIBENZODIOXINS AND DIBENZOFURANS ................. B-13 APPENDIX C . DISTRIBUTION... C -I I I I I I I I I I I I I I xiii I INTENTIONALLY BLANK xiv --I IACKNOWLEDGEMENTS I The following
Mendez, Gregory O.; Foreman, William T.; Morita, Andrew; Majewski, Michael S.
2008-01-01
In 1998, the U.S. Geological Survey, in cooperation with the Sweetwater Authority, began a study to monitor water, air, and sediment at the Sweetwater and Loveland Reservoirs in San Diego County, California. The study includes regular sampling of water and air at Sweetwater Reservoir for chemical constituents, including volatile organic compounds (VOC), polynuclear aromatic hydrocarbons (PAH), pesticides, and major and trace elements. The purpose of this study is to monitor changes in contaminant composition and concentration during the construction and operation of State Route 125. To accomplish this, the study was divided into two phases. Phase One sampling (water years 1998–2004) determined baseline conditions for the detection frequency and the concentrations of target compounds in air and water. Phase Two sampling (starting water year 2005) continues at selected monitoring sites during and after construction of State Route 125 to assess the chemical impact this roadway alignment may have on water quality in the reservoir. Water samples were collected for VOCs and pesticides at Loveland Reservoir during Phase One and will be collected during Phase Two for comparison purposes. Air samples collected to monitor changes in VOCs, PAHs, and pesticides were analyzed by adapting methods used to analyze water samples. Bed-sediment samples have been and will be collected three times during the study; at the beginning of Phase One, at the start of Phase Two, and near the end of the study. In addition to the ongoing data collection, several special studies were initiated to assess the occurrence of specific chemicals of concern, such as trace metals, anthropogenic indicator compounds, and pharmaceuticals. This report describes the study design, and the sampling and analytical methods, and presents data from water and air samples collected during the fourth and fifth years of Phase One of the study (October 2001 to September 2003). Data collected during the first three years has been previously published. Three types of quality-control samples were used in this study: blanks, spikes, and replicates. Blanks and spikes are used to estimate result bias, and replicates are used to estimate result variability. Additionally, surrogate compounds were added at the laboratory to samples of VOCs, PAHs, pesticides, anthropogenic indicator compounds, and pharmaceuticals to monitor sample-specific performance of the analytical method.
Giardi, Fabio; Traversi, Rita; Becagli, Silvia; Severi, Mirko; Caiazzo, Laura; Ancillotti, Claudia; Udisti, Roberto
2018-02-01
An inductively coupled plasma sector field mass spectrometer (ICP-SFMS) was used to develop an analytical method for the fast determination of Na, Al, Sc, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, As, Y, Mo, Cd, Ba, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu, and Pb in Arctic size-segregated aerosol samples (PM 10 ), after microwave acidic digestion. The ICP-SFMS was coupled with a microflow nebulizer and a desolvation system for the sample introduction, which reduced the isobaric interferences due to oxides and the required volume of sample solutions, compared to the usual nebulization chamber methods. With its very low limit of detection, and taking into account the level of blanks, this method allowed the quantification of many metals in very low concentration. Particular attention was given to Rare Earth Elements (REEs - La to Lu). The efficiency in the extraction of REEs was proved to be acceptable, with recoveries over 83% obtained with a Certified Reference Material (AMiS 0356). The analytical method was then applied to particulate matter samples, collected at ground level in Ny Ålesund (Svalbard Islands, Norway), during spring and summer, from 2010 to 2015, with daily resolution and using a low-volume device. Thus, for the first time, a large atmospheric concentrations dataset of metals in Arctic particulate matter at high temporal resolution is presented. On the basis of differences in LREE/HREE ratio and Ce and Eu anomalies in spring and summer samples, basic information to distinguish local and long-range transported dust were achieved. Copyright © 2017 Elsevier B.V. All rights reserved.
Nagai, Yuichiro; Yokoyama, Tetsuya
2014-05-20
A new two-stage chemical separation method was established using an anion exchange resin, Eichrom 1 × 8, to separate Mo and W from four natural rock samples. First, the distribution coefficients of nine elements (Ti, Fe, Zn, Zr, Nb, Mo, Hf, Ta, and W) under various chemical conditions were determined using HCl, HNO3, and HF. On the basis of the obtained distribution coefficients, a new technique for the two-stage chemical separation of Mo and W, along with the group separation of Ti-Zr-Hf, was developed as follows: 0.4 M HCl-0.5 M HF (major elements), 9 M HCl-0.05 M HF (Ti-Zr-Hf), 9 M HCl-1 M HF (W), and 6 M HNO3-3 M HF (Mo). After the chemical procedure, Nb remaining in the W fraction was separated using 9 M HCl-3 M HF. On the other hand, Nb and Zn remaining in the Mo fraction were removed using 2 M HF and 6 M HCl-0.1 M HF. The performance of this technique was evaluated by separating these elements from two terrestrial and two extraterrestrial samples. The recovery yields for Mo, W, Zr, and Hf were nearly 100% for all of the examined samples. The total contents of the Zr, Hf, W, and Mo in the blanks used for the chemical separation procedure were 582, 9, 29, and 396 pg, respectively. Therefore, our new separation technique can be widely used in various fields of geochemistry, cosmochemistry, and environmental sciences and particularly for multi-isotope analysis of these elements from a single sample with significant internal isotope heterogeneities.
Information Operations and FATA Integration into the National Mainstream
2012-09-01
Edward L. Fisher THIS PAGE INTENTIONALLY LEFT BLANK i REPORT DOCUMENTATION PAGE Form Approved OMB No. 0704-0188 Public reporting burden for this...LEFT BLANK vii TABLE OF CONTENTS I . INTRODUCTION ............................................................................................. 1...39 ix i . Computer Network Operations .................................. 40 j. CNO as an IO Core Capability .................................... 40
Nitrogen-Noble Gas Static Mass Sepectrometry of Genesis Collector Materials
NASA Astrophysics Data System (ADS)
Marty, B.; Burnard, P.; Zimmermann, L.; Robert, P.
2005-03-01
Gases (N, Ne, Ar) are extracted from Au-coated sapphire and diamond-like carbon collectors using an F2 excimer laser, without blank contributions the substrate. N is purified using a low blank CuO/Cu cycle prior to analysis by high resolution multicollector mass spectrometer.
ERIC Educational Resources Information Center
Cockriel, Irvin W.
1972-01-01
Occupational scales of the Vocational Preference Inventory were correlated with the Basic Interest scales of the Strong Vocational Interest Blank. The 285 subjects were women freshmen in a College of Education. The results indicate that the scales are not highly correlated. (Author)
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-15
... Concerning Household Goods Carriers Requiring Shippers To Sign Blank or Incomplete Documents AGENCY: Federal.... Basis for This Notice The Agency has received numerous consumer complaints concerning household goods.... The FMCSA is issuing this regulatory guidance to eliminate any ambiguity or confusion concerning the...
Zeleny, Reinhard; Nia, Yacine; Schimmel, Heinz; Mutel, Isabelle; Hennekinne, Jacques-Antoine; Emteborg, Håkan; Charoud-Got, Jean; Auvray, Frédéric
2016-08-01
Staphylococcal enterotoxins (SEs) account for a substantial number of food-poisoning outbreaks. European legislation (Commission Regulation 1441/2007) stipulates the reference procedure for SE analysis in milk and dairy products, which is based on extraction, dialysis concentration and immunochemical detection using one of two approved assays (VIDAS(®) SET2, Ridascreen(®) SET Total). However, certified reference materials (CRMs) are lacking to support laboratories in performing reliable detection of Staphylococcus aureus enterotoxin A (SEA) in relevant matrices at sub-nanogram per gram levels. The certification of a set of three reference materials (blank and two SEA-containing materials) for testing of the presence/absence of SEA in cheese is described. The reference procedure was applied in an intercomparison with 15 laboratories, and results were reported in a qualitative manner (presence or absence of SEA in the sample). No false-negative or false-positive results were obtained. The certified values were stated as diagnostic specificity (blank material) or diagnostic sensitivity (SEA-containing materials) and were 100 % in all cases. Stability studies demonstrated suitable material stability when stored cooled or frozen. An in-house study on the recovery of SEA in the cheese materials using a double-sandwich enzyme-linked immunosorbent assay (ELISA) revealed comparable recovery values of around 45 % at the two spiking levels and in both the SEA-containing CRMs as well as blank CRM freshly spiked prior to analysis. The values were also comparable over time and among different analysts. The materials provide valuable support to laboratories for method validation and method performance verification and will increase the reliability of measuring SEA in cheese.
Measurements of dimethyl sulfide and SO2 during GTE/CITE 3
NASA Technical Reports Server (NTRS)
Ferek, Ronald J.; Hegg, Dean A.
1993-01-01
As part of NASA's Tropospheric Experiment Chemical Instrumentation Test and Evaluation (GTE/CITE 3) Sulfur Gas Intercomparison, we conducted measurements of dimethyl sulfide (DMS) and SO2 using two techniques well suited for sampling from an aircraft due to their simplicity of design. DMS was collected by preconcentration on gold wire preceded by a KOH-impregnated filter oxidant scrubber, and analyzed by gas chromatography with flame photometric detection. SO2 was collected on K2CO3/glycerol-impregnated filters and analyzed by ion chromatography. In blind tests, both techniques produced excellent agreement with National Institutes of Standards and Technology (NIST) standards. For field measurements, the DMS technique produced excellent correlation with the mean of the six different techniques intercompared. For SO2, the five techniques intercompared were rather poorly correlated, but correlations between the three techniques which passed NIST standards tests were somewhat better. Our SO2 filter measurements exhibited rather large uncertainties due to higher than normal variabiltiy of the filter blanks, which we believe was caused by extended storage in the field. In measurements conducted off the coast of Natal, Brazil, a diurnal afternoon minimum in DMS concentrations accompanied by a corresponding maximum in SO2 concentrations was observed. However, due to rather large uncertainties in the SO2 measurements, any conclusions about the SO2 trend must by considered tentative.
Montero, L; Popp, P; Paschke, A; Pawliszyn, J
2004-01-30
A novel, simple and inexpensive approach to absorptive extraction of organic compounds from environmental samples is presented. It consists of a polydimethylsiloxane rod used as an extraction media, enriched with analytes during shaking, then thermally desorbed and analyzed by GC-MS. Its performance was illustrated and evaluated for the enrichment of sub- to ng/l of selected chlorinated compounds (chlorobenzenes and polychlorinated biphenyls) in water samples. The new approach was compared to the stir bar sorptive extraction performance. A natural ground water sample from Bitterfeld, Germany, was also extracted using both methods, showing good agreement. The proposed approach presented good linearity, high sensitivity, good blank levels and recoveries comparable to stir bars, together with advantages such as simplicity, lower cost and higher feasibility.
Yoshioka, Naoki; Ouchi, Hitoshi; Kan, Toshiyuki; Yoshida, Masashi; Nomura, Motoyuki
2017-01-01
A rapid LC-MS method was developed for determination of acromelic acids A and B, which are toxic constituents of Paralepistopsis acromelalga (=Clitocybe acromelalga), in mushroom samples. Acromelic acids were extracted twice with 50% methanol and the extract was passed through a syringe filter, and then analyzed by LC-MS. The LC separation was performed on a multi-mode ODS column. The recoveries of acromelic acids A and B spiked into blank mushroom samples at 2.5 μg/g were 93 and 74%, respectively. This method was applied to the remaining mushroom sample from a food poisoning case. Acromelic acids A and B were detected at 2.0 and 1.4 μg/g, respectively, in the remaining sample. Another toxic constituent, which appeared to be clitidine, was also detected in the sample.
Osborn, Linda V.; Snawder, John E.; Kriech, Anthony J.; Cavallari, Jennifer M.; McClean, Michael D.; Herrick, Robert F.; Blackburn, Gary R.; Olsen, Larry D.
2015-01-01
An exposure assessment of hot-mix asphalt (HMA) paving workers was conducted to determine which of four exposure scenarios impacted worker exposure and dose. Goals of this report are to present the personal-breathing zone (PBZ) data, discuss the impact of substituting the releasing/cleaning agent, and discuss work practices that resulted in the highest exposure concentration for each analyte. One-hundred-seven PBZ samples were collected from HMA paving workers on days when diesel oil was used as a releasing/cleaning agent. An additional 36 PBZ samples were collected on days when B-100 (100% biodiesel, containing no petroleum-derived products) was used as a substitute releasing/cleaning agent. Twenty-four PBZ samples were collected from a reference group of concrete workers, who also worked in outdoor construction but had no exposure to asphalt emissions. Background and field blank samples were also collected daily. Total particulates and the benzene soluble fraction were determined gravimetrically. Total organic matter was determined using gas chromatography (GC) with flame ionization detection and provided qualitative information about other exposure sources contributing to worker exposure besides asphalt emissions. Thirty-three individual polycyclic aromatic compounds (PACs) were determined using GC with time-offlight mass spectrometry; results were presented as either the concentration of an individual PAC or a summation of the individual PACs containing either 2- to 3-rings or 4- to 6-rings. Samples were also screened for PACs containing 4- to 6-rings using fluorescence spectroscopy. Arithmetic means, medians, and box plots of the PBZ data were used to evaluate trends in the data. Box plots illustrating the diesel oil results were more variable than the B-100. Also, the highest diesel oil results were much higher in concentration than the highest B-100 results. An analysis of the highest exposure results and field notes revealed a probable association between these exposures and the use of diesel oil, use of a diesel-powered screed, elevated HMA paving application temperatures, lubricating and working on broken-down equipment, and operation of a broom machine. PMID:24195533
Osborn, Linda V; Snawder, John E; Kriech, Anthony J; Cavallari, Jennifer M; McClean, Michael D; Herrick, Robert F; Blackburn, Gary R; Olsen, Larry D
2013-01-01
An exposure assessment of hot-mix asphalt (HMA) paving workers was conducted to determine which of four exposure scenarios impacted worker exposure and dose. Goals of this report are to present the personal-breathing zone (PBZ) data, discuss the impact of substituting the releasing/cleaning agent, and discuss work practices that resulted in the highest exposure concentration for each analyte. One-hundred-seven PBZ samples were collected from HMA paving workers on days when diesel oil was used as a releasing/cleaning agent. An additional 36 PBZ samples were collected on days when B-100 (100% biodiesel, containing no petroleum-derived products) was used as a substitute releasing/cleaning agent. Twenty-four PBZ samples were collected from a reference group of concrete workers, who also worked in outdoor construction but had no exposure to asphalt emissions. Background and field blank samples were also collected daily. Total particulates and the benzene soluble fraction were determined gravimetrically. Total organic matter was determined using gas chromatography (GC) with flame ionization detection and provided qualitative information about other exposure sources contributing to worker exposure besides asphalt emissions. Thirty-three individual polycyclic aromatic compounds (PACs) were determined using GC with time-of-flight mass spectrometry; results were presented as either the concentration of an individual PAC or a summation of the individual PACs containing either 2- to 3-rings or 4- to 6-rings. Samples were also screened for PACs containing 4- to 6-rings using fluorescence spectroscopy. Arithmetic means, medians, and box plots of the PBZ data were used to evaluate trends in the data. Box plots illustrating the diesel oil results were more variable than the B-100. Also, the highest diesel oil results were much higher in concentration than the highest B-100 results. An analysis of the highest exposure results and field notes revealed a probable association between these exposures and the use of diesel oil, use of a diesel-powered screed, elevated HMA paving application temperatures, lubricating and working on broken-down equipment, and operation of a broom machine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Linard, Joshua; Campbell, Sam
This event included annual sampling of groundwater and surface water locations at the Gunnison, Colorado, Processing Site. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites. Samples were collected from 28 monitoring wells, three domestic wells, and six surface locations in April at the processing site as specified in the 2010 Ground Water Compliance Action Plan for the Gunnison, Colorado, Processing Site. Domestic wells 0476 and 0477 were sampled in July because the homes were unoccupied in April, and the wells were not in use. Duplicate samplesmore » were collected from locations 0113, 0248, and 0477. One equipment blank was collected during this sampling event. Water levels were measured at all monitoring wells that were sampled. No issues were identified during the data validation process that requires additional action or follow-up.« less
2012-01-01
Background Multiplex cytometric bead assay (CBA) have a number of advantages over ELISA for antibody testing, but little information is available on standardization and validation of antibody CBA to multiple Plasmodium falciparum antigens. The present study was set to determine optimal parameters for multiplex testing of antibodies to P. falciparum antigens, and to compare results of multiplex CBA to ELISA. Methods Antibodies to ten recombinant P. falciparum antigens were measured by CBA and ELISA in samples from 30 individuals from a malaria endemic area of Kenya and compared to known positive and negative control plasma samples. Optimal antigen amounts, monoplex vs multiplex testing, plasma dilution, optimal buffer, number of beads required were assessed for CBA testing, and results from CBA vs. ELISA testing were compared. Results Optimal amounts for CBA antibody testing differed according to antigen. Results for monoplex CBA testing correlated strongly with multiplex testing for all antigens (r = 0.88-0.99, P values from <0.0001 - 0.004), and antibodies to variants of the same antigen were accurately distinguished within a multiplex reaction. Plasma dilutions of 1:100 or 1:200 were optimal for all antigens for CBA testing. Plasma diluted in a buffer containing 0.05% sodium azide, 0.5% polyvinylalcohol, and 0.8% polyvinylpyrrolidone had the lowest background activity. CBA median fluorescence intensity (MFI) values with 1,000 antigen-conjugated beads/well did not differ significantly from MFI with 5,000 beads/well. CBA and ELISA results correlated well for all antigens except apical membrane antigen-1 (AMA-1). CBA testing produced a greater range of values in samples from malaria endemic areas and less background reactivity for blank samples than ELISA. Conclusion With optimization, CBA may be the preferred method of testing for antibodies to P. falciparum antigens, as CBA can test for antibodies to multiple recombinant antigens from a single plasma sample and produces a greater range of values in positive samples and lower background readings for blank samples than ELISA. PMID:23259607
Total Mercury in Surface and Deep Waters in the Western and Eastern Mediterranean Sea
NASA Astrophysics Data System (ADS)
Varde', M.; Cofone, F.; Servidio, A.; Rosselli, A.; Hedgecock, I. M.; Ammoscato, I.; Mannarino, V.; Sprovieri, F.; Gensini, M.; Pirrone, N.
2014-12-01
In the framework of the Italian National Research Council (CNR) Med-Oceanor measurement program and as part of the Global Mercury Observation System (GMOS) objectives, we performed two cruise campaigns with the CNR's Research Vessel (RV) Urania, in the western and eastern Mediterranean Basin, in the summers of 2012 and 2013. Total Mercury (THg) concentration in seawater was systematically measured at different depths from the sea bottom to the surface. A total of 155 surface and deep seawater samples at 25 selected stations were collected during the cruise campaigns using a stainless-steel rosette system on which 24 Niskin bottles (10L) were mounted. Continuous monitoring of temperature, conductivity, salinity and oxygen with depth were obtained by CTD measurements. All fluorinated containers were cleaned prior to use following GMOS SOPs. The chemical reagents used were suitable for ultra-trace Hg analysis. After sampling, samples were preserved by adding HCl solution to the sample bottles, which were refrigerated during transportation and analyzed within four weeks of the end of the oceanographic campaign. Sea water samples were analyzed in the laboratory following the US-EPA 1631 method revision E (US-EPA, 2002). To assess the critical issues related to mercury (Hg) contamination and to prevent leakage of Hg through volatilization we used all necessary precautions for sampling, sample stabilization, preservation and subsequent analysis in the laboratory. Quality assurance and quality control were performed using transport blanks, laboratory blanks and use of seawater certified reference materials. The accuracy of the analytical procedures for the determination of THg in sea water was corroborated by participation in a global inter-laboratory comparison study for THg in natural waters. THg concentrations in surface and deep waters found in the Mediterranean basin during the last two cruise campaigns Med-Oceanor as well as the THg measurements in sea water collected in the other programs and oceanographic campaigns will help to further our understanding of Hg marine distribution and its impact on the biogeochemical cycle of Hg in the open ocean.
Goldrath, Dara A.; Wright, Michael T.; Belitz, Kenneth
2010-01-01
Groundwater quality in the 188-square-mile Colorado River Study unit (COLOR) was investigated October through December 2007 as part of the Priority Basin Project of the California State Water Resources Control Board (SWRCB) Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basin Project was developed in response to the Groundwater Quality Monitoring Act of 2001, and the U.S. Geological Survey (USGS) is the technical project lead. The Colorado River study was designed to provide a spatially unbiased assessment of the quality of raw groundwater used for public water supplies within COLOR, and to facilitate statistically consistent comparisons of groundwater quality throughout California. Samples were collected from 28 wells in three study areas in San Bernardino, Riverside, and Imperial Counties. Twenty wells were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the Study unit; these wells are termed 'grid wells'. Eight additional wells were selected to evaluate specific water-quality issues in the study area; these wells are termed `understanding wells.' The groundwater samples were analyzed for organic constituents (volatile organic compounds [VOC], gasoline oxygenates and degradates, pesticides and pesticide degradates, pharmaceutical compounds), constituents of special interest (perchlorate, 1,4-dioxane, and 1,2,3-trichlorpropane [1,2,3-TCP]), naturally occurring inorganic constituents (nutrients, major and minor ions, and trace elements), and radioactive constituents. Concentrations of naturally occurring isotopes (tritium, carbon-14, and stable isotopes of hydrogen and oxygen in water), and dissolved noble gases also were measured to help identify the sources and ages of the sampled groundwater. In total, approximately 220 constituents and water-quality indicators were investigated. Quality-control samples (blanks, replicates, and matrix spikes) were collected at approximately 30 percent of the wells, and the results were used to evaluate the quality of the data obtained from the groundwater samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that contamination was not a significant source of bias in the data. Differences between replicate samples were within acceptable ranges and matrix-spike recoveries were within acceptable ranges for most compounds. This study did not attempt to evaluate the quality of water delivered to consumers; after withdrawal from the ground, raw groundwater typically is treated, disinfected, or blended with other waters to maintain acceptable water quality. Regulatory thresholds apply to water that is served to the consumer, not to raw groundwater. However, to provide some context for the results, concentrations of constituents measured in the raw groundwater were compared to regulatory and nonregulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA) and the California Department of Public Health (CDPH) and to thresholds established for aesthetic concerns by CDPH. Comparisons between data collected for this study and drinking-water thresholds are for illustrative purposes only and do not indicate compliance or noncompliance with those thresholds. The concentrations of most constituents detected in groundwater samples were below drinking-water thresholds. Volatile organic compounds (VOC) were detected in approximately 35 percent of grid well samples; all concentrations were below health-based thresholds. Pesticides and pesticide degradates were detected in about 20 percent of all samples; detections were below health-based thresholds. No concentrations of constituents of special interest or nutrients were detected above health-based thresholds. Most of the major and minor ion constituents sampled do not have health-based thresholds; the exception is chloride. Concentrations of chloride, sulfate, and total dis
Information model construction of MES oriented to mechanical blanking workshop
NASA Astrophysics Data System (ADS)
Wang, Jin-bo; Wang, Jin-ye; Yue, Yan-fang; Yao, Xue-min
2016-11-01
Manufacturing Execution System (MES) is one of the crucial technologies to implement informatization management in manufacturing enterprises, and the construction of its information model is the base of MES database development. Basis on the analysis of the manufacturing process information in mechanical blanking workshop and the information requirement of MES every function module, the IDEF1X method was adopted to construct the information model of MES oriented to mechanical blanking workshop, and a detailed description of the data structure feature included in MES every function module and their logical relationship was given from the point of view of information relationship, which laid the foundation for the design of MES database.
The Fiscal Blank Check Policy and Its Impact on Operation Iraqi Freedom
2006-12-01
facilities across Iraq has a significant logistical and financial tail associated with it. The increase in food and beverages (to the point of luxuries) has...THIS PAGE INTENTIONALLY LEFT BLANK v ABSTRACT Congress passed declaration of war language for World Wars I and...78 V . CONCLUSION AND RECOMMENDATIONS
Intellectual Property Rights for Digital Design and Manufacturing: Issues and Recommendations
2014-06-30
for Public Release, Distribution Unlimited. iv This page intentionally left blank. Distribution A: Approved for...Distribution A: Approved for Public Release, Distribution Unlimited. viii This page intentionally left blank...challenges requires an analysis of intellectual property management and recommendations for its use in a cooperative as well as competitive market
2007-06-01
THIS PAGE INTENTIONALLY LEFT BLANK i NSN 7540-01-280-5500 Standard Form 298 (Rev. 2-89) Prescribed by ANSI Std. 239-18...4 I . INTRODUCTION............................................................................................. 7 A. SCOPE...6 THIS PAGE INTENTIONALLY LEFT BLANK 7 I . INTRODUCTION A. SCOPE The intent
Strong Vocational Interest Blank Scores for Junior College Students in Five Curricula.
ERIC Educational Resources Information Center
Smith, Stuart E.
An investigation was conducted to determine if students in five junior college curricula could be differentiated by the Strong Vocational Interest Blank (SVIB) scores and if such differentiation could be improved by using several scores in combination rather than single scores separately. The SVIB was administered to 130 students at Alfred…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-02
... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-72,041] Aleris Blanking and Rim Products, Inc., a Division of Aleris International, Inc., Terre Haute, IN; Notice of Affirmative Determination Regarding Application for Reconsideration By application dated January 29, 2010, the petitioner...
47 CFR 73.642 - Subscription TV service.
Code of Federal Regulations, 2011 CFR
2011-10-01
... available to the FCC upon request. (d) The use of the visual vertical blanking interval or an aural... programming may be used only upon specific FCC authorization. Letter requests to use either the video blanking intervals or aural subcarriers during periods of non-subscription programming are to be sent to the FCC in...
47 CFR 73.642 - Subscription TV service.
Code of Federal Regulations, 2010 CFR
2010-10-01
... available to the FCC upon request. (d) The use of the visual vertical blanking interval or an aural... programming may be used only upon specific FCC authorization. Letter requests to use either the video blanking intervals or aural subcarriers during periods of non-subscription programming are to be sent to the FCC in...
Shimelmitz, Ron; Kuhn, Steven L.; Ronen, Avraham; Weinstein-Evron, Mina
2014-01-01
While predetermined débitage technologies are recognized beginning with the middle Acheulian, the Middle Paleolithic is usually associated with a sharp increase in their use. A study of scraper-blank technology from three Yabrudian assemblages retrieved from the early part of the Acheulo-Yabrudian complex of Tabun Cave (ca. 415–320 kyr) demonstrates a calculated and preplanned production, even if it does not show the same complexity and elaboration as in the Levallois technology. These scraper dominated assemblages show an organization of production based on an intensive use of predetermination blank technology already in place at the end of the Lower Paleolithic of the Levant. These results provide a novel perspective on the differences and similarities between the Lower and Middle Paleolithic industries. We suggest that there was a change in the paradigm in the way hominins exploited stone tools: in many Middle Paleolithic assemblages the potential of the stone tools for hafting was a central feature, in the Lower Paleolithic ergonometric considerations of manual prehension were central to the design of blanks and tools. PMID:25192429
NASA Astrophysics Data System (ADS)
Zheng, Lijuan; Cao, Fan; Xiu, Junshan; Bai, Xueshi; Motto-Ros, Vincent; Gilon, Nicole; Zeng, Heping; Yu, Jin
2014-09-01
Laser-induced breakdown spectroscopy (LIBS) provides a technique to directly determine metals in viscous liquids and especially in lubricating oils. A specific laser ablation configuration of a thin layer of oil applied on the surface of a pure aluminum target was used to evaluate the analytical figures of merit of LIBS for elemental analysis of lubricating oils. Among the analyzed oils, there were a certified 75cSt blank mineral oil, 8 virgin lubricating oils (synthetic, semi-synthetic, or mineral and of 2 different manufacturers), 5 used oils (corresponding to 5 among the 8 virgin oils), and a cooking oil. The certified blank oil and 4 virgin lubricating oils were spiked with metallo-organic standards to obtain laboratory reference samples with different oil matrix. We first established calibration curves for 3 elements, Fe, Cr, Ni, with the 5 sets of laboratory reference samples in order to evaluate the matrix effect by the comparison among the different oils. Our results show that generalized calibration curves can be built for the 3 analyzed elements by merging the measured line intensities of the 5 sets of spiked oil samples. Such merged calibration curves with good correlation of the merged data are only possible if no significant matrix effect affects the measurements of the different oils. In the second step, we spiked the remaining 4 virgin oils and the cooking oils with Fe, Cr and Ni. The accuracy and the precision of the concentration determination in these prepared oils were then evaluated using the generalized calibration curves. The concentrations of metallic elements in the 5 used lubricating oils were finally determined.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Swadling, G. F.; Ross, J. S.; Manha, D.
The design principles of a xenon gas shield device that is intended to protect optical components from x-ray induced opacity (“x-ray blanking”) have been experimentally demonstrated at the OMEGA-60 Laser Facility at the Laboratory for Laser Energetics, University of Rochester. A volume of xenon gas placed in front of an optical component absorbs the incoming soft x-ray radiation but transmits optical and ultra-violet radiation. The time-resolved optical (532 nm) transmission of samples was recorded as they were exposed to soft x-rays produced by a gold sphere source (1.5 kJ sr $-$1, 250–300 eV). Blanking of fused silica (SiO 2) wasmore » measured to occur over a range of time-integrated soft x-ray (<3 keV) fluence from ~0.2–2.5 J cm $-$2. A shield test device consisting of a 30 nm silicon nitride (Si 3N 4) and a 10 cm long volume of 0.04 bar xenon gas succeeded in delaying loss of transmission through a magnesium fluoride sample; optical transmission was observed over a longer period than for the unprotected sample. It is hoped that the design of this x-ray shield can be scaled in order to produce a shield device for the National Ignition Facility optical Thomson scattering collection telescope, in order to allow measurements of hohlraum plasma conditions produced in inertial confinement fusion experiments. Finally, if successful, it will also have applications in many other high energy density experiments where optical and ultra-violet measurements are desirable.« less
Swadling, G. F.; Ross, J. S.; Manha, D.; ...
2017-03-16
The design principles of a xenon gas shield device that is intended to protect optical components from x-ray induced opacity (“x-ray blanking”) have been experimentally demonstrated at the OMEGA-60 Laser Facility at the Laboratory for Laser Energetics, University of Rochester. A volume of xenon gas placed in front of an optical component absorbs the incoming soft x-ray radiation but transmits optical and ultra-violet radiation. The time-resolved optical (532 nm) transmission of samples was recorded as they were exposed to soft x-rays produced by a gold sphere source (1.5 kJ sr $-$1, 250–300 eV). Blanking of fused silica (SiO 2) wasmore » measured to occur over a range of time-integrated soft x-ray (<3 keV) fluence from ~0.2–2.5 J cm $-$2. A shield test device consisting of a 30 nm silicon nitride (Si 3N 4) and a 10 cm long volume of 0.04 bar xenon gas succeeded in delaying loss of transmission through a magnesium fluoride sample; optical transmission was observed over a longer period than for the unprotected sample. It is hoped that the design of this x-ray shield can be scaled in order to produce a shield device for the National Ignition Facility optical Thomson scattering collection telescope, in order to allow measurements of hohlraum plasma conditions produced in inertial confinement fusion experiments. Finally, if successful, it will also have applications in many other high energy density experiments where optical and ultra-violet measurements are desirable.« less
The CAMELS data set: catchment attributes and meteorology for large-sample studies
NASA Astrophysics Data System (ADS)
Addor, Nans; Newman, Andrew J.; Mizukami, Naoki; Clark, Martyn P.
2017-10-01
We present a new data set of attributes for 671 catchments in the contiguous United States (CONUS) minimally impacted by human activities. This complements the daily time series of meteorological forcing and streamflow provided by Newman et al. (2015b). To produce this extension, we synthesized diverse and complementary data sets to describe six main classes of attributes at the catchment scale: topography, climate, streamflow, land cover, soil, and geology. The spatial variations among basins over the CONUS are discussed and compared using a series of maps. The large number of catchments, combined with the diversity of the attributes we extracted, makes this new data set well suited for large-sample studies and comparative hydrology. In comparison to the similar Model Parameter Estimation Experiment (MOPEX) data set, this data set relies on more recent data, it covers a wider range of attributes, and its catchments are more evenly distributed across the CONUS. This study also involves assessments of the limitations of the source data sets used to compute catchment attributes, as well as detailed descriptions of how the attributes were computed. The hydrometeorological time series provided by Newman et al. (2015b, https://doi.org/10.5065/D6MW2F4D) together with the catchment attributes introduced in this paper (https://doi.org/10.5065/D6G73C3Q) constitute the freely available CAMELS data set, which stands for Catchment Attributes and MEteorology for Large-sample Studies.
Extraction of Solar Wind Nitrogen and Noble Gases From the Genesis Gold Foil Collector
NASA Astrophysics Data System (ADS)
Schlutter, D. J.; Pepin, R. O.
2005-12-01
The Genesis gold foil is a bulk solar wind collector, integrating fluences from all three of the wind regimes. Pyrolytic extraction of small foil samples at Minnesota yielded He fluences, corrected for backscatter, in good agreement with measurements by on-board spacecraft instruments, and He/Ne elemental ratios close to those implanted in collector foils deployed on the lunar surface during the Apollo missions. Isotopic distributions of He, Ne and Ar are under study. Pyrolysis to temperatures above the gold melting point generates nitrogen blanks large enough to obscure the solar-wind nitrogen component. An alternative technique for nitrogen and noble gas extraction, by room-temperature amalgamation of the gold foil surface, will be discussed. Ne and Ar releases in preliminary tests of this technique on small foil samples were close to 100% of the amounts expected from the high-temperature pyrolysis yields, indicating that amalgamation quantitatively liberates gases from several hundred angstroms deep in the gold, beyond the implantation depth of most of the solar wind. Present work is focused on two problems currently interfering with accurate nitrogen measurements at the required picogram to sub-picogram levels: a higher than expected blank likely due to tiny air bubbles rolled into the gold sheet during fabrication, and the presence of a refractory hydrocarbon film on Genesis collector surfaces (the "brown stain") that, if left in place on the foil, shields the underlying gold from mercury attack. We have found, however, that the film is efficiently removed within tens of seconds by oxygen plasma ashing. Potential nitrogen contaminants introduced during the crash of the sample return canister are inert in amalgamation, and so are not hazards to the measurements.
Wetherbee, Gregory A.; Latysh, Natalie E.; Greene, Shannon M.
2006-01-01
The U.S. Geological Survey (USGS) used five programs to provide external quality-assurance monitoring for the National Atmospheric Deposition Program/National Trends Network (NADP/NTN) and two programs to provide external quality-assurance monitoring for the NADP/Mercury Deposition Network (NADP/MDN) during 2004. An intersite-comparison program was used to estimate accuracy and precision of field-measured pH and specific-conductance. The variability and bias of NADP/NTN data attributed to field exposure, sample handling and shipping, and laboratory chemical analysis were estimated using the sample-handling evaluation (SHE), field-audit, and interlaboratory-comparison programs. Overall variability of NADP/NTN data was estimated using a collocated-sampler program. Variability and bias of NADP/MDN data attributed to field exposure, sample handling and shipping, and laboratory chemical analysis were estimated using a system-blank program and an interlaboratory-comparison program. In two intersite-comparison studies, approximately 89 percent of NADP/NTN site operators met the pH measurement accuracy goals, and 94.7 to 97.1 percent of NADP/NTN site operators met the accuracy goals for specific conductance. Field chemistry measurements were discontinued by NADP at the end of 2004. As a result, the USGS intersite-comparison program also was discontinued at the end of 2004. Variability and bias in NADP/NTN data due to sample handling and shipping were estimated from paired-sample concentration differences and specific conductance differences obtained for the SHE program. Median absolute errors (MAEs) equal to less than 3 percent were indicated for all measured analytes except potassium and hydrogen ion. Positive bias was indicated for most of the measured analytes except for calcium, hydrogen ion and specific conductance. Negative bias for hydrogen ion and specific conductance indicated loss of hydrogen ion and decreased specific conductance from contact of the sample with the collector bucket. Field-audit results for 2004 indicate dissolved analyte loss in more than one-half of NADP/NTN wet-deposition samples for all analytes except chloride. Concentrations of contaminants also were estimated from field-audit data. On the basis of 2004 field-audit results, at least 25 percent of the 2004 NADP/NTN concentrations for sodium, potassium, and chloride were lower than the maximum sodium, potassium, and chloride contamination likely to be found in 90 percent of the samples with 90-percent confidence. Variability and bias in NADP/NTN data attributed to chemical analysis by the NADP Central Analytical Laboratory (CAL) were comparable to the variability and bias estimated for other laboratories participating in the interlaboratory-comparison program for all analytes. Variability in NADP/NTN ammonium data evident in 2002-03 was reduced substantially during 2004. Sulfate, hydrogen-ion, and specific conductance data reported by CAL during 2004 were positively biased. A significant (a = 0.05) bias was identified for CAL sodium, potassium, ammonium, and nitrate data, but the absolute values of the median differences for these analytes were less than the method detection limits. No detections were reported for CAL analyses of deionized-water samples, indicating that contamination was not a problem for CAL. Control charts show that CAL data were within statistical control during at least 90 percent of 2004. Most 2004 CAL interlaboratory-comparison results for synthetic wet-deposition solutions were within ?10 percent of the most probable values (MPVs) for solution concentrations except for chloride, nitrate, sulfate, and specific conductance results from one sample in November and one specific conductance result in December. Overall variability of NADP/NTN wet-deposition measurements was estimated during water year 2004 by the median absolute errors for weekly wet-deposition sample concentrations and precipitation measurements for tw
Fernández-Ramos, C; Ballesteros, O; Zafra-Gómez, A; Blanc, R; Navalón, A; Crovetto, G; Cantarero, S; Oliver-Rodríguez, B; Vílchez, J L
2013-09-01
The number of analytical methodologies that focus in the determination of alcohol sulfates (AS) and alcohol ethoxysulfates (AES) in terrestrial environment is very limited. In the present work, a new methodology to improve the extraction and determination of AS and AES in agricultural soil samples has been developed. Prior to instrumental analysis, an extraction procedure using pressurized liquid extraction with methanol (PLE) was carried out in order to obtain the highest recoveries and improve sensitivity. The most influential variables affecting the PLE procedure were optimized. Then, the separation and quantification of analytes were performed by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). The limits of detection (LOD) ranged from 0.03 to 0.08μgg(-1) for AS homologues and in the case of AES ethoxymers from 0.03 to 0.09μgg(-1) for AES-C12Ex and from 0.03 to 0.08μgg(-1) for AES-C14Ex. Matrix-matched calibration was used. Trueness was evaluated by using a spike recovery assay with spiked blank samples, and the recoveries ranged from 98.3% to 101.0% for AS and from 99.9% to 100.1% for AES. The method was satisfactorily applied in a field study designed to evaluate the environmental behavior of these compounds in agricultural soil. Copyright © 2013 Elsevier Ltd. All rights reserved.
Kabir, Md Humayun; Abd El-Aty, A M; Kim, Sung-Woo; Lee, Han Sol; Rahman, Md Musfiqur; Lee, Young-Jun; Chung, Hyung Suk; Lieu, Truong; Choi, Jeong-Heui; Shin, Ho-Chul; Im, Geon-Jae; Hong, Su Myeong; Shim, Jae-Han
2016-11-01
This study was conducted to characterize the residual level and perform a risk assessment on buprofezin formulated as an emulsifiable concentrate, wettable powder, and suspension concentrate over various treatment schedules in plum (Prunus domestica). The samples were extracted with an AOAC quick, easy, cheap, effective, rugged, and safe, 'QuEChERS', method after major modifications. As intrinsic interferences were observed in blank plum samples following dispersive-solid phase extraction (consisting of primary secondary amine and C 18 sorbents), amino cartridges were used for solid-phase extraction. Analysis was carried out using liquid chromatography with diode array detection and confirmed by liquid chromatography-tandem mass spectrometry. The method showed excellent linearity with determination coefficient (R 2 = 1) and satisfactory recoveries (at two spiking levels, 0.5 and 2.5 mg/kg) between 90.98 and 94.74% with relative standard deviation (RSD) ≤8%. The limit of quantification (0.05 mg/kg) was considerably lower than the maximum residue limit (2 mg/kg) set by the Codex Alimentarius. Absolute residue levels for emulsifiable concentrates were highest, perhaps owing to the dilution rate and adjuvant. Notably, all formulation residues were lower than the maximum residue limit, and safety data proved that the fruits are safe for consumers. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Bis-aptazyme sensors for hepatitis C virus replicase and helicase without blank signal
Cho, Suhyung; Kim, Ji-Eun; Lee, Bo-Rahm; Kim, June-Hyung; Kim, Byung-Gee
2005-01-01
The fusion molecule (i.e. aptazyme) of aptamer and hammerhead ribozyme was developed as in situ sensor. Previously, the hammerhead ribozyme conjugated with aptamer through its stem II module showed a significant blank signal by self-cleavage. To reduce or remove its self-cleavage activity in the absence of target molecule, rational designs were attempted by reducing the binding affinity of the aptazyme to its RNA substrate, while maintaining the ribonuclease activity of the aptazyme. Interestingly, the bis-aptazymes which comprise the two aptamer-binding sites at both stem I and stem III of the hammerhead ribozyme showed very low blank signals, and their ratios of reaction rate constants, i.e. signal to noise ratios, were several tens to hundred times higher than those of the stem II-conjugated bis-aptazymes. The reduction in the blank signals seems to be caused by a higher dissociation constant between the main strand of the bis-aptazyme and its substrate arising from multi-point base-pairing of the bis-aptazymes. The bis-aptazymes for HCV replicase and helicase showed high selectivity against other proteins, and a linear relationship existed between their ribozyme activities and the target concentrations. In addition, a bis-aptazyme of dual functions was designed by inserting both aptamers for HCV replicase and helicase into the stem I and stem III of hammerhead ribozyme, respectively, and it also showed greater sensitivity and specificity for both proteins without blank signal. PMID:16314308
Dogs can discriminate human smiling faces from blank expressions.
Nagasawa, Miho; Murai, Kensuke; Mogi, Kazutaka; Kikusui, Takefumi
2011-07-01
Dogs have a unique ability to understand visual cues from humans. We investigated whether dogs can discriminate between human facial expressions. Photographs of human faces were used to test nine pet dogs in two-choice discrimination tasks. The training phases involved each dog learning to discriminate between a set of photographs of their owner's smiling and blank face. Of the nine dogs, five fulfilled these criteria and were selected for test sessions. In the test phase, 10 sets of photographs of the owner's smiling and blank face, which had previously not been seen by the dog, were presented. The dogs selected the owner's smiling face significantly more often than expected by chance. In subsequent tests, 10 sets of smiling and blank face photographs of 20 persons unfamiliar to the dogs were presented (10 males and 10 females). There was no statistical difference between the accuracy in the case of the owners and that in the case of unfamiliar persons with the same gender as the owner. However, the accuracy was significantly lower in the case of unfamiliar persons of the opposite gender to that of the owner, than with the owners themselves. These results suggest that dogs can learn to discriminate human smiling faces from blank faces by looking at photographs. Although it remains unclear whether dogs have human-like systems for visual processing of human facial expressions, the ability to learn to discriminate human facial expressions may have helped dogs adapt to human society.
Radial-rotation profile forming: A new processing technology of incremental sheet metal forming
NASA Astrophysics Data System (ADS)
Laue, Robert; Härtel, Sebastian; Awiszus, Birgit
2018-05-01
Incremental forming processes (i.e., spinning) of sheet metal blanks into cylindrical cups are suitable for lower lot sizes. The produced cups were frequently used as preforms to produce workpieces in further forming steps with additional functions like profiled hollow parts [1]. The incremental forming process radial-rotation profile forming has been developed to enable the production of profiled hollow parts with low sheet thinning and good geometrical accuracy. The two principal forming steps are the production of the preform by rotational swing-folding [2] and the subsequent radial profiling of the hollow part in one clamping position. The rotational swing-folding process is based on a combination of conventional spinning and swing-folding. Therefore, a round blank rotates on a profiled mandrel and due to the swinging of a cylindrical forming tool, the blank is formed to a cup with low sheet thinning. In addition, thickening results at the edge of the blank and wrinkling occurs. However, the wrinkles are formed into the indentation of the profiled mandrel and can be reshaped as an advantage in the second process step, the radial profiling. Due to the rotation and continuous radial feed of a profiled forming tool to the profiled mandrel, the axial profile is formed in the second process step. Because of the minor relative movement in axial direction between tool and blank, low sheet thinning occurs. This is an advantage of the principle of the process.
Characterization and Validation of the LT-SYS Copper Assay on a Roche Cobas 8000 c502 Analyzer.
Kraus, F Bernhard; Mischereit, Marlies; Eller, Christoph; Ludwig-Kraus, Beatrice
2017-02-01
Validation of the LT-SYS quantitative in vitro copper assay on a Roche Cobas 8000 c502 analyzer and comparison with a BIOMED assay on a Roche Cobas Mira analyzer. Imprecision and bias were quantified at different concentration levels (serum and plasma) over a 20-day period. Linearity was assessed covering a range from 4.08 µmol/L to 33.8 µmol/L. Limit of blank (LoB) and limit of detection (LoD) were established based on a total of 120 blank and low-level samples. The method comparison was based on 58 plasma samples. Within-run imprecision ranged from 0.7% to 1.2% and within-laboratory imprecision from 1.4% to 3.3%. Relative bias for the 2 serum pools with known target values was less than 2.5%. The assay did not deviate from linearity over the tested measuring range. LoB and LoD were 0.12 µmol/L and 0.23 µmol/L, respectively. The method comparison revealed an average deviation of 11.5% (2.016 µmol/L), and the linear regression fit was y = 1.464 + 0.795x. The LT-SYS copper assay characterized in this study showed a fully acceptable performance with good degrees of imprecision and bias, no deviation from linearity in the relevant measuring rangem, and very low LoB and LoD. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Nelson, David M.; Hu, Feng Sheng; Mikucki, Jill A.; Tian, Jian; Pearson, Ann
2007-08-01
Pollen grains from grasses using the C 3 and C 4 photosynthetic pathways have distinct ranges of δ 13C values that may be used to estimate their relative abundance in paleorecords. We evaluated a spooling-wire microcombustion device interfaced with an isotope-ratio mass spectrometer (SWiM-IRMS) for δ 13C analysis of individual grass-pollen grains. Pollen from four C 3 and four C 4 grass species was isolated through micromanipulation and analyzed as single grains suspended in water. A carbon yield greater than the 2 σ range of the carbon content of blanks containing only water was used to distinguish samples containing pollen ("pollen present") from those not containing pollen. This criterion resulted in the exclusion of ˜45% of the 946 samples applied to the wire. The average δ 13C values (±1 σ) of the remaining samples were -26.9‰ (±6.3‰) and -11.5‰ (±9.6‰) for C 3 grasses and C 4 grasses, respectively, after blank-correcting the δ 13C data. These results suggest that the SWiM-IRMS system can be used to distinguish C 3 from C 4 grass pollen. The high variability in measured δ 13C values is likely caused by a combination of factors. These include natural isotopic variability among individual pollen grains; the relatively poor precision that can be obtained when determining δ 13C values of such small samples; and the uncertainty in the magnitude, isotopic composition, and stability of the analytical blank. Nonetheless, high percentages of individual pollen grains were correctly classified as being of either C 3 or C 4 origin. On average, 90% (range = 78-100%) of pollen grains from C 3 grasses had δ 13C values more negative than the cutoff threshold of -19.2‰; while 84% (range = 77-90%) of pollen grains from C 4 grasses had δ 13C values more positive than -19.2‰. Compared with analysis using an elemental analyzer interfaced with an IRMS (EA-IRMS), the number of pollen grains required for δ 13C-based evaluation of C 3/C 4 grass composition is many times lower with the SWiM-IRMS. Additionally, δ 13C data from the SWiM-IRMS does not need to be incorporated into a mixing model to derive estimates of the abundance of C 3 and C 4 grass pollen. Carbon-isotopic analysis of individual grass-pollen grains using the SWiM-IRMS system may help improve our understanding of the evolutionary and ecological significance of grass taxa in the paleorecord.
NASA Astrophysics Data System (ADS)
Chen, Chian-Chou; Smail, Ian; Swinbank, A. M.; Simpson, James M.; Almaini, Omar; Conselice, Christopher J.; Hartley, Will G.; Mortlock, Alice; Simpson, Chris; Wilkinson, Aaron
2016-11-01
The properties of submillimeter galaxies (SMGs) that are fainter than the confusion limit of blank-field single-dish surveys ({S}850 ≲ 2 mJy) are poorly constrained. Using a newly developed color selection technique, Optical-Infrared Triple Color (OIRTC), that has been shown to successfully select such faint SMGs, we identify a sample of 2938 OIRTC-selected galaxies, dubbed Triple Color Galaxies (TCGs), in the UKIDSS-UDS field. We show that these galaxies have a median 850 μm flux of {S}850=0.96+/- 0.04 mJy (equivalent to a star formation rate SFR ˜ 60{--}100 {M}⊙ yr-1 based on spectral energy distribution fitting), representing the first large sample of faint SMGs that bridges the gap between bright SMGs and normal star-forming galaxies in S 850 and L IR. We assess the basic properties of TCGs and their relationship with other galaxy populations at z˜ 2. We measure the two-point autocorrelation function for this population and derive a typical halo mass of log10({M}{halo}) = {12.9}-0.3+0.2, {12.7}-0.2+0.1, and {12.9}-0.3+0.2 {h}-1 {M}⊙ at z=1{--}2, 2-3, and 3-5, respectively. Together with the bright SMGs ({S}850≳ 2 mJy) and a comparison sample of less far-infrared luminous star-forming galaxies, we find a lack of dependence between spatial clustering and S 850 (or SFR), suggesting that the difference between these populations may lie in their local galactic environment. Lastly, on the scale of ˜ 8{--}17 {kpc} at 1\\lt z\\lt 5 we find a tentative enhancement of the clustering of TCGs over the comparison star-forming galaxies, suggesting that some faint SMGs are physically associated pairs, perhaps reflecting a merging origin in their triggering.
Moerland, Robert J; Weppelman, I Gerward C; Garming, Mathijs W H; Kruit, Pieter; Hoogenboom, Jacob P
2016-10-17
We show cathodoluminescence-based time-resolved electron beam spectroscopy in order to directly probe the spontaneous emission decay rate that is modified by the local density of states in a nanoscale environment. In contrast to dedicated laser-triggered electron-microscopy setups, we use commercial hardware in a standard SEM, which allows us to easily switch from pulsed to continuous operation of the SEM. Electron pulses of 80-90 ps duration are generated by conjugate blanking of a high-brightness electron beam, which allows probing emitters within a large range of decay rates. Moreover, we simultaneously attain a resolution better than λ/10, which ensures details at deep-subwavelength scales can be retrieved. As a proof-of-principle, we employ the pulsed electron beam to spatially measure excited-state lifetime modifications in a phosphor material across the edge of an aluminum half-plane, coated on top of the phosphor. The measured emission dynamics can be directly related to the structure of the sample by recording photon arrival histograms together with the secondary-electron signal. Our results show that time-resolved electron cathodoluminescence spectroscopy is a powerful tool of choice for nanophotonics, within reach of a large audience.
Two months of disdrometer data in the Paris area
NASA Astrophysics Data System (ADS)
Gires, Auguste; Tchiguirinskaia, Ioulia; Schertzer, Daniel
2018-05-01
The Hydrology, Meteorology, and Complexity laboratory of École des Ponts ParisTech (hmco.enpc.fr) has made a data set of optical disdrometer measurements available that come from a campaign involving three collocated devices from two different manufacturers, relying on different underlying technologies (one Campbell Scientific PWS100 and two OTT Parsivel2 instruments). The campaign took place in January-February 2016 in the Paris area (France). Disdrometers provide access to information on the size and velocity of drops falling through the sampling area of the devices of roughly a few tens of cm2. It enables the drop size distribution to be estimated and rainfall microphysics, kinetic energy, or radar quantities, for example, to be studied further. Raw data, i.e. basically a matrix containing a number of drops according to classes of size and velocity, along with more aggregated ones, such as the rain rate or drop size distribution with filtering, are available. Link to the data set: https://zenodo.org/record/1240168 (DOI: https://doi.org/10.5281/zenodo.1240168).
Code of Federal Regulations, 2011 CFR
2011-10-01
... Blanking Interval and in the Visual Signal. 73.646 Section 73.646 Telecommunication FEDERAL COMMUNICATIONS... transmission of data, processed information, or any other communication in either a digital or analog mode. (b... kinds of service that may be provided include, but are not limited to, teletext, paging, computer...
Code of Federal Regulations, 2014 CFR
2014-10-01
... Blanking Interval and in the Visual Signal. 73.646 Section 73.646 Telecommunication FEDERAL COMMUNICATIONS... transmission of data, processed information, or any other communication in either a digital or analog mode. (b... kinds of service that may be provided include, but are not limited to, teletext, paging, computer...
Code of Federal Regulations, 2012 CFR
2012-10-01
... Blanking Interval and in the Visual Signal. 73.646 Section 73.646 Telecommunication FEDERAL COMMUNICATIONS... transmission of data, processed information, or any other communication in either a digital or analog mode. (b... kinds of service that may be provided include, but are not limited to, teletext, paging, computer...
Code of Federal Regulations, 2010 CFR
2010-10-01
... Blanking Interval and in the Visual Signal. 73.646 Section 73.646 Telecommunication FEDERAL COMMUNICATIONS... transmission of data, processed information, or any other communication in either a digital or analog mode. (b... kinds of service that may be provided include, but are not limited to, teletext, paging, computer...
U.S. Foreign Policy’s Role in Homeland Security: The Egyptian Case
2011-12-01
Robert E. Looney THIS PAGE INTENTIONALLY LEFT BLANK i REPORT DOCUMENTATION PAGE Form Approved OMB No. 0704-0188 Public reporting burden for this...CONTENTS I . INTRODUCTION........................................................................................................1 A. MAJOR RESEARCH...PAGE INTENTIONALLY LEFT BLANK xi ACKNOWLEDGMENTS I would like to thank Dr. Abbas Kadhim and Dr. Robert Looney for their support, expertise, and
A big blank white canvas? Mapping and modeling human impact in Antarctica
Steve Carver; Tina Tin
2015-01-01
Antarctica is certainly what most people would consider being the world's last great wilderness; largely untouched and undeveloped by humans. Yet it is not inviolate - there are scientific bases, tourist operations, expeditions, airstrips and even roads. Although these impacts are by and large limited in extent, their very presence in an otherwise "blank...
The Disposition of Topically Applied Agents
1981-09-24
S . op . cit. 28. Scheuplein R.J., Blank I.H. op. cit. 29. Lorenzetti O.J. Cosmet. Toil. 93_:49-50, 1978. 30. Scheuplein R.J., Blank I.H. op. cit...Riegelman S . op . cit. 37. Wester R. , Noonan P J. invest. Derm. 72:92-94, 1978. 38. Mansel-Jones D., Taylor T., Doyle E., Chasseud L.F., Darraugh A
Hardwood Blanks Expand Export Opportunities
Bruce G. Hansen; Philip A. Araman
1985-01-01
This article reviews the latest statistics pertaining to the export of hardwood lumber to the Pacific Rim; discusses possible reasons for the emergence and growth of this market; offers alternatives to rough hardwood lumber (two forms of value-added, hardwood blanks); and develops estimates of prices needed at the mill to earn a 30% return on investment from the...
Optimal Number of Gaps in C-Test Passages
ERIC Educational Resources Information Center
Baghaei, Purya
2011-01-01
This study addresses the issue of the optimal number of gaps in C-Test passages. An English C-Test battery containing four passages each having 40 blanks was given to 104 undergraduate students of English. The data were entered into SPSS spreadsheet. Out of the complete data with 160 blanks seven additional datasets were constructed. In the first…
ERIC Educational Resources Information Center
Bredeson, Paul V.
1988-01-01
Reports on a study of the use of employment application blanks as prescreening devices in public school employee selection. Findings suggest two major areas for further research. The first relates to legal compliance with Equal Opportunity Employment guidelines. The second concerns information relevancy to personnel selection. (JAM)
Meeting the Solid Wood Needs of the Furniture and Cabinet Industries: Standard-Size Hardwood Blanks
Philip A. Araman; Charles J Gatchell; Hugh W. Reynolds
1982-01-01
Standard-size, kiln-dried hardwood blanks (panels) of specified lengths, widths, thicknesses, and qualities can be used instead of lumber to produce rough dimension furniture parts. Standard sizes were determined by analyzing thousands of part requirements from 20 furniture and 12 kitchen cabinet companies. The International Woodworking Machinery and Furniture Supply...
System 6 alternatives: an economic analysis
Bruce G. Hansen; Hugh W. Reynolds; Hugh W. Reynolds
1984-01-01
Three System 6 mill-size alternatives were designed and evaluated to determine their overall economic potential for producing standard-size hardwood blanks. Internal rates of return ranged from about 15 to 35 percent after taxes. Cost per square foot of blanks ranged from about $0.88 to $1.19, depending on mill size and the amount of new investment required.
Production of EUV mask blanks with low killer defects
NASA Astrophysics Data System (ADS)
Antohe, Alin O.; Kearney, Patrick; Godwin, Milton; He, Long; John Kadaksham, Arun; Goodwin, Frank; Weaver, Al; Hayes, Alan; Trigg, Steve
2014-04-01
For full commercialization, extreme ultraviolet lithography (EUVL) technology requires the availability of EUV mask blanks that are free of defects. This remains one of the main impediments to the implementation of EUV at the 22 nm node and beyond. Consensus is building that a few small defects can be mitigated during mask patterning, but defects over 100 nm (SiO2 equivalent) in size are considered potential "killer" defects or defects large enough that the mask blank would not be usable. The current defect performance of the ion beam sputter deposition (IBD) tool will be discussed and the progress achieved to date in the reduction of large size defects will be summarized, including a description of the main sources of defects and their composition.
Actinic defect counting statistics over 1-cm2 area of EUVL mask blank
NASA Astrophysics Data System (ADS)
Jeong, Seongtae; Lai, Chih-wei; Rekawa, Senajith; Walton, Christopher C.; Bokor, Jeffrey
2000-07-01
As a continuation of comparison experiments between EUV inspection and visible inspection of defects on EUVL mask blanks, we report on the result of an experiment where the EUV defect inspection tool is used to perform at-wavelength defect counting over 1 cm2 of EUVL mask blank. Initial EUV inspection found five defects over the scanned area and the subsequent optical scattering inspection was able to detect all of the five defects. Therefore, if there are any defects that are only detectable by EUV inspection, the density is lower than the order of unity per cm2. An upgrade path to substantially increase the overall throughput of the EUV inspection system is also identified in the manuscript.
Formability analysis of austenitic stainless steel-304 under warm conditions
NASA Astrophysics Data System (ADS)
Lade, Jayahari; Singh, Swadesh Kumar; Banoth, Balu Naik; Gupta, Amit Kumar
2013-12-01
A warm deep drawing process of austenitic stainless steel-304 (ASS-304) of circular blanks with coupled ther mal analysis is studied in this article. 65 mm blanks were deep drawn at different temperatures and thickness distribution is experimentally measured after cutting the drawn component into two halves. The process is simulated using explicit fin ite element code LS-DYNA. A Barlat 3 parameter model is used in the simulation, as the material is anisotropic up to 30 0°C. Material properties for the simulation are determined at different temperatures using a 5 T UTM coupled with a furn ace. In this analysis constant punch speed and variable blank holder force (BHF) is applied to draw cups without wrinkle.
Fill in the blank: culture jamming and the advertising of agency.
Lambert-Beatty, Carrie
2010-01-01
This article is a review on billboard liberation and some other proj-ects that develop the idea of talking back or over advertising in a playful and youthful way. In one of them, Ji Lee's Bubble Project, an artist places blank thought-bubble stickers on street advertisements and waits to see what people write on them, completing the work of art and transgression. In other initiative, blank pages with the word God were placed around the city in place of advertising, inviting people to complete the prayer/complaint and to participate in a Suggestion Box, a project that collected "suggestions" from people out in the street. A review of playful and youthful ways to "rebel" against the impositions of powers like media and advertising.