Sample records for field collected samples

  1. Protocol for collecting eDNA samples from streams [Version 2.3

    Treesearch

    K. J. Carim; T. Wilcox; M. K. Young; K. S. McKelvey; M. K. Schwartz

    2015-01-01

    Throughout the 2014 field season, we had over two dozen biologist throughout the western US collect over 300 samples for eDNA analysis with paired controls. Control samples were collected by filtering 0.5 L of distilled water. No samples had any evidence of field contamination. This method of sampling verifies the cleanliness of the field equipment, as well as the...

  2. Anopheles sinensis mosquito insecticide resistance: comparison of three mosquito sample collection and preparation methods and mosquito age in resistance measurements.

    PubMed

    Xu, Tielong; Zhong, Daibin; Tang, Linhua; Chang, Xuelian; Fu, Fengyang; Yan, Guiyun; Zheng, Bin

    2014-01-28

    Insecticide resistance monitoring in malaria mosquitoes is essential for guiding the rational use of insecticides in vector control programs. Resistance bioassay is the first step for insecticide monitoring and it lays an important foundation for molecular examination of resistance mechanisms. In the literature, various mosquito sample collection and preparation methods have been used, but how mosquito sample collection and preparation methods affect insecticide susceptibility bioassay results is largely unknown. The objectives of this study were to determine whether mosquito sample collection and preparation methods affected bioassay results, which may cause incorrect classification of mosquito resistance status. The study was conducted in Anopheles sinensis mosquitoes in two study sites in central China. Three mosquito sample collection and preparation methods were compared for insecticide susceptibility, kdr frequencies and metabolic enzyme activities: 1) adult mosquitoes collected from the field; 2) F1 adults from field collected, blood-fed mosquitoes; and 3) adult mosquitoes reared from field collected larvae. Mosquito sample collection and preparation methods significantly affected mortality rates in the standard WHO tube resistance bioassay. Mortality rate of field-collected female adults was 10-15% higher than in mosquitoes reared from field-collected larvae and F1 adults from field collected blood-fed females. This pattern was consistent in mosquitoes from the two study sites. High kdr mutation frequency (85-95%) with L1014F allele as the predominant mutation was found in our study populations. Field-collected female adults consistently exhibited the highest monooxygenase and GST activities. The higher mortality rate observed in the field-collected female mosquitoes may have been caused by a mixture of mosquitoes of different ages, as older mosquitoes were more susceptible to deltamethrin than younger mosquitoes. Female adults reared from field-collected larvae in resistance bioassays are recommended to minimize the effect of confounding factors such as mosquito age and blood feeding status so that more reliable and reproducible mortality may be obtained.

  3. Use of Electronic Hand-held Devices for Collection of Savannah River Site Environmental Data - 13329

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marberry, Hugh; Moore, Winston

    2013-07-01

    Savannah River Nuclear Solutions has begun using Xplore Tablet PC's to collect data in the field for soil samples, groundwater samples, air samples and round sheets at the Savannah River Site (SRS). EPA guidelines for groundwater sampling are incorporated into the application to ensure the sample technician follows the proper protocol. The sample technician is guided through the process for sampling and round sheet data collection by a series of menus and input boxes. Field measurements and well stabilization information are entered into the tablet for uploading into Environmental Restoration Data Management System (ERDMS). The process helps to eliminate inputmore » errors and provides data integrity. A soil sample technician has the ability to collect information about location of sample, field parameter, describe the soil sample, print bottle labels, and print chain of custody for the sample that they have collected. An air sample technician has the ability to provide flow, pressure, hours of operation, print bottle labels and chain of custody for samples they collect. Round sheets are collected using the information provided in the various procedures. The data are collected and uploaded into ERDMS. The equipment used is weather proof and hardened for the field use. Global Positioning System (GPS) capabilities are integrated into the applications to provide the location where samples were collected and to help sample technicians locate wells that are not visited often. (authors)« less

  4. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR FIELD COLLECTION OF INDOOR FLOOR SAMPLES AND POST FIELD SAMPLE HANDLING (UA-F-7.1)

    EPA Science Inventory

    The purpose of this SOP is to establish a uniform procedure for the collection of indoor floor dust samples in the field. This procedure was followed to ensure consistent data retrieval of dust samples during the Arizona NHEXAS project and the "Border" study. Keywords: field; va...

  5. Investigation of differences between field and laboratory pH measurements of national atmospheric deposition program/national trends network precipitation samples

    USGS Publications Warehouse

    Latysh, N.; Gordon, J.

    2004-01-01

    A study was undertaken to investigate differences between laboratory and field pH measurements for precipitation samples collected from 135 weekly precipitation-monitoring sites in the National Trends Network from 12/30/1986 to 12/28/1999. Differences in pH between field and laboratory measurements occurred for 96% of samples collected during this time period. Differences between the two measurements were evaluated for precipitation samples collected before and after January 1994, when modifications to sample-handling protocol and elimination of the contaminating bucket o-ring used in sample shipment occurred. Median hydrogen-ion and pH differences between field and laboratory measurements declined from 3.9 ??eq L-1 or 0.10 pH units before the 1994 protocol change to 1.4 ??eq L-1 or 0.04 pH units after the 1994 protocol change. Hydrogen-ion differences between field and laboratory measurements had a high correlation with the sample pH determined in the field. The largest pH differences between the two measurements occurred for high-pH samples (>5.6), typical of precipitation collected in Western United States; however low- pH samples (<5.0) displayed the highest variability in hydrogen-ion differences between field and laboratory analyses. Properly screened field pH measurements are a useful alternative to laboratory pH values for trend analysis, particularly before 1994 when laboratory pH values were influenced by sample-collection equipment.

  6. Guidelines for collection and field analysis of ground-water samples for selected unstable constituents

    USGS Publications Warehouse

    Wood, Warren W.

    1976-01-01

    The unstable nature of many chemical and physical constituents in ground water requires special collection procedures and field analysis immediately after collection. This report describes the techniques and equipment commonly used m the collection and field analysis of samples for pH, temperature, carbonate, bicarbonate, specific conductance, Eh, and dissolved oxygen.

  7. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR FIELD COLLECTION AND POST-FIELD SAMPLE HANDLING OF INDOOR FLOOR DUST SAMPLES (UA-F-7.1)

    EPA Science Inventory

    The purpose of this SOP is to establish a uniform procedure for the collection of indoor floor dust samples in the field. This procedure was followed to ensure consistent data retrieval of dust samples during the Arizona NHEXAS project and the Border study. Keywords: field; vacu...

  8. Introduction to Field Water-Quality Methods for the Collection of Metals - 2007 Project Summary

    USGS Publications Warehouse

    Allen, Monica L.

    2008-01-01

    The U.S. Geological Survey (USGS), Region VI of the U.S. Environmental Protection Agency (USEPA), and the Osage Nation presented three 3-day workshops, in June-August 2007, entitled ?Introduction to Field Water-Quality Methods for the Collection of Metals.? The purpose of the workshops was to provide instruction to tribes within USEPA Region VI on various USGS surface-water measurement methods and water-quality sampling protocols for the collection of surface-water samples for metals analysis. Workshop attendees included members from over 22 tribes and pueblos. USGS instructors came from Oklahoma, New Mexico, and Georgia. Workshops were held in eastern and south-central Oklahoma and New Mexico and covered many topics including presampling preparation, water-quality monitors, and sampling for metals in surface water. Attendees spent one full classroom day learning the field methods used by the USGS Water Resources Discipline and learning about the complexity of obtaining valid water-quality and quality-assurance data. Lectures included (1) a description of metal contamination sources in surface water; (2) introduction on how to select field sites, equipment, and laboratories for sample analysis; (3) collection of sediment in surface water; and (4) utilization of proper protocol and methodology for sampling metals in surface water. Attendees also were provided USGS sampling equipment for use during the field portion of the class so they had actual ?hands-on? experience to take back to their own organizations. The final 2 days of the workshop consisted of field demonstrations of current USGS water-quality sample-collection methods. The hands-on training ensured that attendees were exposed to and experienced proper sampling procedures. Attendees learned integrated-flow techniques during sample collection, field-property documentation, and discharge measurements and calculations. They also used enclosed chambers for sample processing and collected quality-assurance samples to verify their techniques. Benefits of integrated water-quality sample-collection methods are varied. Tribal environmental programs now have the ability to collect data that are comparable across watersheds. The use of consistent sample collection, manipulation, and storage techniques will provide consistent quality data that will enhance the understanding of local water resources. The improved data quality also will help the USEPA better document the condition of the region?s water. Ultimately, these workshops equipped tribes to use uniform sampling methods and to provide consistent quality data that are comparable across the region.

  9. The Use of Handheld X-Ray Fluorescence (XRF) Technology in Unraveling the Eruptive History of the San Francisco Volcanic Field, Arizona

    NASA Technical Reports Server (NTRS)

    Young, Kelsey E.; Evans, C. A.; Hodges, K. V.

    2012-01-01

    While traditional geologic mapping includes the examination of structural relationships between rock units in the field, more advanced technology now enables us to simultaneously collect and combine analytical datasets with field observations. Information about tectonomagmatic processes can be gleaned from these combined data products. Historically, construction of multi-layered field maps that include sample data has been accomplished serially (first map and collect samples, analyze samples, combine data, and finally, readjust maps and conclusions about geologic history based on combined data sets). New instruments that can be used in the field, such as a handheld xray fluorescence (XRF) unit, are now available. Targeted use of such instruments enables geologists to collect preliminary geochemical data while in the field so that they can optimize scientific data return from each field traverse. Our study tests the application of this technology and projects the benefits gained by real-time geochemical data in the field. The integrated data set produces a richer geologic map and facilitates a stronger contextual picture for field geologists when collecting field observations and samples for future laboratory work. Real-time geochemical data on samples also provide valuable insight regarding sampling decisions by the field geologist

  10. Design and evaluation of a field study on the contamination of selected volatile organic compounds and wastewater-indicator compounds in blanks and groundwater samples

    USGS Publications Warehouse

    Thiros, Susan A.; Bender, David A.; Mueller, David K.; Rose, Donna L.; Olsen, Lisa D.; Martin, Jeffrey D.; Bernard, Bruce; Zogorski, John S.

    2011-01-01

    The Field Contamination Study (FCS) was designed to determine the field processes that tend to result in clean field blanks and to identify potential sources of contamination to blanks collected in the field from selected volatile organic compounds (VOCs) and wastewater-indicator compounds (WICs). The VOCs and WICs analyzed in the FCS were detected in blanks collected by the U.S. Geological Survey (USGS) National Water-Quality Assessment (NAWQA) Program during 1996–2008 and 2002–08, respectively. To minimize the number of variables, the study required ordering of supplies just before sampling, storage of supplies and equipment in clean areas, and use of adequate amounts of purge-and-trap volatile-grade methanol and volatile pesticide-grade blank water (VPBW) to clean sampling equipment and to collect field blanks.Blanks and groundwater samples were collected during 2008–09 at 16 sites, which were a mix of water-supply and monitoring wells, located in 9 States. Five different sample types were collected for the FCS at each site: (1) a source-solution blank collected at the USGS National Water Quality Laboratory (NWQL) using laboratory-purged VPBW, (2) source-solution blanks collected in the field using laboratory-purged VPBW, (3) source-solution blanks collected in the field using field-purged VPBW, (4) a field blank collected using field-purged VPBW, and (5) a groundwater sample collected from a well. The source-solution blank and field-blank analyses were used to identify, quantify, and document extrinsic contamination and to help determine the sources and causes of data-quality problems that can affect groundwater samples.Concentrations of compounds detected in FCS analyses were quantified and results were stored in the USGS National Water Information System database after meeting rigorous identification and quantification criteria. The study also utilized information provided by laboratory analysts about evidence indicating the presence of selected compounds, using less rigorous identification criteria than is required for reporting data to the National Water Information System database. For the FCS, these data are considered adequate to indicate "evidence of presence," and were used only for diagnostic purposes. Evidence of VOCs and WICs at low concentrations near or less than the long-term method detection level can indicate a contamination problem that could affect future datasets if method detection levels were ever to be lowered.

  11. Field guide for collecting and processing stream-water samples for the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Shelton, Larry R.

    1994-01-01

    The U.S. Geological Survey's National Water-Quality Assessment program includes extensive data- collection efforts to assess the quality of the Nations's streams. These studies require analyses of stream samples for major ions, nutrients, sediments, and organic contaminants. For the information to be comparable among studies in different parts of the Nation, consistent procedures specifically designed to produce uncontaminated samples for trace analysis in the laboratory are critical. This field guide describes the standard procedures for collecting and processing samples for major ions, nutrients, organic contaminants, sediment, and field analyses of conductivity, pH, alkalinity, and dissolved oxygen. Samples are collected and processed using modified and newly designed equipment made of Teflon to avoid contamination, including nonmetallic samplers (D-77 and DH-81) and a Teflon sample splitter. Field solid-phase extraction procedures developed to process samples for organic constituent analyses produce an extracted sample with stabilized compounds for more accurate results. Improvements to standard operational procedures include the use of processing chambers and capsule filtering systems. A modified collecting and processing procedure for organic carbon is designed to avoid contamination from equipment cleaned with methanol. Quality assurance is maintained by strict collecting and processing procedures, replicate sampling, equipment blank samples, and a rigid cleaning procedure using detergent, hydrochloric acid, and methanol.

  12. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR FIELD COLLECTION OF YARD COMPOSITE SOIL SAMPLES (UA-F-5.1)

    EPA Science Inventory

    The purpose of this SOP is to establish a uniform procedure for the collection of yard composite soil samples in the field. This procedure was followed to ensure consistent and reliable collection of outdoor soil samples during the Arizona NHEXAS project and the "Border" study. ...

  13. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR FIELD COLLECTION OF RESIDENTIAL FOUNDATION SOIL SAMPLES (UA-F-6.1)

    EPA Science Inventory

    The purpose of this SOP is to establish a uniform procedure for the collection of residential foundation soil samples in the field. This procedure was followed to ensure consistent and reliable collection of outdoor soil samples during the Arizona NHEXAS project and the "Border"...

  14. Sampling procedure for lake or stream surface water chemistry

    Treesearch

    Robert Musselman

    2012-01-01

    Surface waters collected in the field for chemical analyses are easily contaminated. This research note presents a step-by-step detailed description of how to avoid sample contamination when field collecting, processing, and transporting surface water samples for laboratory analysis.

  15. Field Summary Report for Remedial Investigation of Hanford Site Releases to the Columbia River, Hanford Site, Washington

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    L.C. Hulstrom

    2010-09-28

    This report documents field activity associated with the collection, preparation, and shipment of fish samples. The purpose of the report is to describe the sampling locations, identify samples collected, and describe any modifications and additions made to the sampling and analysis plan.

  16. Benthic macroinvertebrate field sampling effort required to ...

    EPA Pesticide Factsheets

    This multi-year pilot study evaluated a proposed field method for its effectiveness in the collection of a benthic macroinvertebrate sample adequate for use in the condition assessment of streams and rivers in the Neuquén Province, Argentina. A total of 13 sites, distributed across three rivers, were sampled. At each site, benthic macroinvertebrates were collected at 11 transects. Each sample was processed independently in the field and laboratory. Based on a literature review and resource considerations, the collection of 300 organisms (minimum) at each site was determined to be necessary to support a robust condition assessment, and therefore, selected as the criterion for judging the adequacy of the method. This targeted number of organisms was collected at all sites, at a minimum, when collections from all 11 transects were combined. Subsequent bootstrapping analysis of data was used to estimate whether collecting at fewer transects would reach the minimum target number of organisms for all sites. In a subset of sites, the total number of organisms frequently fell below the target when fewer than 11 transects collections were combined.Site conditions where <300 organisms might be collected are discussed. These preliminary results suggest that the proposed field method results in a sample that is adequate for robust condition assessment of the rivers and streams of interest. When data become available from a broader range of sites, the adequacy of the field

  17. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR FIELD COLLECTION OF YARD COMPOSITE SOIL SAMPLES (UA-F-5.1)

    EPA Science Inventory

    The purpose of this SOP is to establish a uniform procedure for the collection of yard composite soil samples in the field. This procedure was followed to ensure consistent and reliable collection of outdoor soil samples during the Arizona NHEXAS project and the Border study. Ke...

  18. Corn blight review: Sampling model and ground data measurements program

    NASA Technical Reports Server (NTRS)

    Allen, R. D.

    1972-01-01

    The sampling plan involved the selection of the study area, determination of the flightline and segment sample design within the study area, and determination of a field sample design. Initial interview survey data consisting of crop species acreage and land use were collected. On all corn fields, additional information such as seed type, row direction, population, planting date, ect. were also collected. From this information, sample corn fields were selected to be observed through the growing season on a biweekly basis by county extension personnel.

  19. Field guide for collecting samples for analysis of volatile organic compounds in stream water for the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Shelton, Larry R.

    1997-01-01

    For many years, stream samples for analysis of volatile organic compounds have been collected without specific guidelines or a sampler designed to avoid analyte loss. In 1996, the U.S. Geological Survey's National Water-Quality Assessment Program began aggressively monitoring urban stream-water for volatile organic compounds. To assure representative samples and consistency in collection procedures, a specific sampler was designed to collect samples for analysis of volatile organic compounds in stream water. This sampler, and the collection procedures, were tested in the laboratory and in the field for compound loss, contamination, sample reproducibility, and functional capabilities. This report describes that sampler and its use, and outlines field procedures specifically designed to provide contaminant-free, reproducible volatile organic compound data from stream-water samples. These guidelines and the equipment described represent a significant change in U.S. Geological Survey instructions for collecting and processing stream-water samples for analysis of volatile organic compounds. They are intended to produce data that are both defensible and interpretable, particularly for concentrations below the microgram-per-liter level. The guidelines also contain detailed recommendations for quality-control samples.

  20. Surface Environmental Surveillance Procedures Manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hanf, RW; Dirkes, RL

    1990-02-01

    This manual establishes the procedures for the collection of environmental samples and the performance of radiation surveys and other field measurements. Responsibilities are defined for those personnel directly involved in the collection of samples and the performance of field measurements.

  1. CTEPP STANDARD OPERATING PROCEDURE FOR SETTING UP A HOUSEHOLD SAMPLING SCHEDULE (SOP-2.10)

    EPA Science Inventory

    This SOP describes the method for scheduling study subjects for field sampling activities in North Carolina (NC) and Ohio (OH). There are three field sampling teams with two staff members on each team. Two field sampling teams collect the field data simultaneously. A third fiel...

  2. Quality-control design for surface-water sampling in the National Water-Quality Network

    USGS Publications Warehouse

    Riskin, Melissa L.; Reutter, David C.; Martin, Jeffrey D.; Mueller, David K.

    2018-04-10

    The data-quality objectives for samples collected at surface-water sites in the National Water-Quality Network include estimating the extent to which contamination, matrix effects, and measurement variability affect interpretation of environmental conditions. Quality-control samples provide insight into how well the samples collected at surface-water sites represent the true environmental conditions. Quality-control samples used in this program include field blanks, replicates, and field matrix spikes. This report describes the design for collection of these quality-control samples and the data management needed to properly identify these samples in the U.S. Geological Survey’s national database.

  3. Towards Making Data Bases Practical for use in the Field

    NASA Astrophysics Data System (ADS)

    Fischer, T. P.; Lehnert, K. A.; Chiodini, G.; McCormick, B.; Cardellini, C.; Clor, L. E.; Cottrell, E.

    2014-12-01

    Geological, geochemical, and geophysical research is often field based with travel to remote areas and collection of samples and data under challenging environmental conditions. Cross-disciplinary investigations would greatly benefit from near real-time data access and visualisation within the existing framework of databases and GIS tools. An example of complex, interdisciplinary field-based and data intensive investigations is that of volcanologists and gas geochemists, who sample gases from fumaroles, hot springs, dry gas vents, hydrothermal vents and wells. Compositions of volcanic gas plumes are measured directly or by remote sensing. Soil gas fluxes from volcanic areas are measured by accumulation chamber and involve hundreds of measurements to calculate the total emission of a region. Many investigators also collect rock samples from recent or ancient volcanic eruptions. Structural, geochronological, and geophysical data collected during the same or related field campaigns complement these emissions data. All samples and data collected in the field require a set of metadata including date, time, location, sample or measurement id, and descriptive comments. Currently, most of these metadata are written in field notebooks and later transferred into a digital format. Final results such as laboratory analyses of samples and calculated flux data are tabulated for plotting, correlation with other types of data, modeling and finally publication and presentation. Data handling, organization and interpretation could be greatly streamlined by using digital tools available in the field to record metadata, assign an International Geo Sample Number (IGSN), upload measurements directly from field instruments, and arrange sample curation. Available data display tools such as GeoMapApp and existing data sets (PetDB, IRIS, UNAVCO) could be integrated to direct locations for additional measurements during a field campaign. Nearly live display of sampling locations, pictures, and comments could be used as an educational and outreach tool during sampling expeditions. Achieving these goals requires the integration of existing online data resources, with common access through a dedicated web portal.

  4. General introduction for the “National Field Manual for the Collection of Water-Quality Data”

    USGS Publications Warehouse

    ,

    2018-02-28

    BackgroundAs part of its mission, the U.S. Geological Survey (USGS) collects data to assess the quality of our Nation’s water resources. A high degree of reliability and standardization of these data are paramount to fulfilling this mission. Documentation of nationally accepted methods used by USGS personnel serves to maintain consistency and technical quality in data-collection activities. “The National Field Manual for the Collection of Water-Quality Data” (NFM) provides documented guidelines and protocols for USGS field personnel who collect water-quality data. The NFM provides detailed, comprehensive, and citable procedures for monitoring the quality of surface water and groundwater. Topics in the NFM include (1) methods and protocols for sampling water resources, (2) methods for processing samples for analysis of water quality, (3) methods for measuring field parameters, and (4) specialized procedures, such as sampling water for low levels of mercury and organic wastewater chemicals, measuring biological indicators, and sampling bottom sediment for chemistry. Personnel who collect water-quality data for national USGS programs and projects, including projects supported by USGS cooperative programs, are mandated to use protocols provided in the NFM per USGS Office of Water Quality Technical Memorandum 2002.13. Formal training, for example, as provided in the USGS class, “Field Water-Quality Methods for Groundwater and Surface Water,” and field apprenticeships supplement the guidance provided in the NFM and ensure that the data collected are high quality, accurate, and scientifically defensible.

  5. Risk factors associated with Salmonella and Listeria monocytogenes contamination of produce fields.

    PubMed

    Strawn, Laura K; Gröhn, Yrjo T; Warchocki, Steven; Worobo, Randy W; Bihn, Elizabeth A; Wiedmann, Martin

    2013-12-01

    Identification of management practices associated with preharvest pathogen contamination of produce fields is crucial to the development of effective Good Agricultural Practices (GAPs). A cross-sectional study was conducted to (i) determine management practices associated with a Salmonella- or Listeria monocytogenes-positive field and (ii) quantify the frequency of these pathogens in irrigation and nonirrigation water sources. Over 5 weeks, 21 produce farms in New York State were visited. Field-level management practices were recorded for 263 fields, and 600 environmental samples (soil, drag swab, and water) were collected and analyzed for Salmonella and L. monocytogenes. Management practices were evaluated for their association with the presence of a pathogen-positive field. Salmonella and L. monocytogenes were detected in 6.1% and 17.5% of fields (n = 263) and 11% and 30% of water samples (n = 74), respectively. The majority of pathogen-positive water samples were from nonirrigation surface water sources. Multivariate analysis showed that manure application within a year increased the odds of a Salmonella-positive field (odds ratio [OR], 16.7), while the presence of a buffer zone had a protective effect (OR, 0.1). Irrigation (within 3 days of sample collection) (OR, 6.0), reported wildlife observation (within 3 days of sample collection) (OR, 6.1), and soil cultivation (within 7 days of sample collection) (OR, 2.9) all increased the likelihood of an L. monocytogenes-positive field. Our findings provide new data that will assist growers with science-based evaluation of their current GAPs and implementation of preventive controls that reduce the risk of preharvest contamination.

  6. Risk Factors Associated with Salmonella and Listeria monocytogenes Contamination of Produce Fields

    PubMed Central

    Gröhn, Yrjo T.; Warchocki, Steven; Worobo, Randy W.; Bihn, Elizabeth A.; Wiedmann, Martin

    2013-01-01

    Identification of management practices associated with preharvest pathogen contamination of produce fields is crucial to the development of effective Good Agricultural Practices (GAPs). A cross-sectional study was conducted to (i) determine management practices associated with a Salmonella- or Listeria monocytogenes-positive field and (ii) quantify the frequency of these pathogens in irrigation and nonirrigation water sources. Over 5 weeks, 21 produce farms in New York State were visited. Field-level management practices were recorded for 263 fields, and 600 environmental samples (soil, drag swab, and water) were collected and analyzed for Salmonella and L. monocytogenes. Management practices were evaluated for their association with the presence of a pathogen-positive field. Salmonella and L. monocytogenes were detected in 6.1% and 17.5% of fields (n = 263) and 11% and 30% of water samples (n = 74), respectively. The majority of pathogen-positive water samples were from nonirrigation surface water sources. Multivariate analysis showed that manure application within a year increased the odds of a Salmonella-positive field (odds ratio [OR], 16.7), while the presence of a buffer zone had a protective effect (OR, 0.1). Irrigation (within 3 days of sample collection) (OR, 6.0), reported wildlife observation (within 3 days of sample collection) (OR, 6.1), and soil cultivation (within 7 days of sample collection) (OR, 2.9) all increased the likelihood of an L. monocytogenes-positive field. Our findings provide new data that will assist growers with science-based evaluation of their current GAPs and implementation of preventive controls that reduce the risk of preharvest contamination. PMID:24077713

  7. A FIELD VALIDATION OF TWO SEDIMENT-AMPHIPOD TOXICITY TESTS

    EPA Science Inventory

    A field validation study of two sediment-amphipod toxicity tests was conducted using sediment samples collected subtidally in the vicinity of a polycyclic aromatic hydrocarbon (PAH)-contaminated Superfund site in Elliott Bay, WA, USA. Sediment samples were collected at 30 stati...

  8. From Field to the Web: Management and Publication of Geoscience Samples in CSIRO Mineral Resources

    NASA Astrophysics Data System (ADS)

    Devaraju, A.; Klump, J. F.; Tey, V.; Fraser, R.; Reid, N.; Brown, A.; Golodoniuc, P.

    2016-12-01

    Inaccessible samples are an obstacle to the reproducibility of research and may cause waste of time and resources through duplication of sample collection and management. Within the Commonwealth Scientific and Industrial Research Organisation (CSIRO) Mineral Resources there are various research communities who collect or generate physical samples as part of their field studies and analytical processes. Materials can be varied and could be rock, soil, plant materials, water, and even synthetic materials. Given the wide range of applications in CSIRO, each researcher or project may follow their own method of collecting, curating and documenting samples. In many cases samples and their documentation are often only available to the sample collector. For example, the Australian Resources Research Centre stores rock samples and research collections dating as far back as the 1970s. Collecting these samples again would be prohibitively expensive and in some cases impossible because the site has been mined out. These samples would not be easily discoverable by others without an online sample catalog. We identify some of the organizational and technical challenges to provide unambiguous and systematic access to geoscience samples, and present their solutions (e.g., workflow, persistent identifier and tools). We present the workflow starting from field sampling to sample publication on the Web, and describe how the International Geo Sample Number (IGSN) can be applied to identify samples along the process. In our test case geoscientific samples are collected as part of the Capricorn Distal Footprints project, a collaboration project between the CSIRO, the Geological Survey of Western Australia, academic institutions and industry partners. We conclude by summarizing the values of our solutions in terms of sample management and publication.

  9. Methods for collection and analysis of water samples

    USGS Publications Warehouse

    Rainwater, Frank Hays; Thatcher, Leland Lincoln

    1960-01-01

    This manual contains methods used by the U.S. Geological Survey to collect, preserve, and analyze water samples. Throughout, the emphasis is on obtaining analytical results that accurately describe the chemical composition of the water in situ. Among the topics discussed are selection of sampling sites, frequency of sampling, field equipment, preservatives and fixatives, analytical techniques of water analysis, and instruments. Seventy-seven laboratory and field procedures are given for determining fifty-three water properties.

  10. Characterization of nutrients and fecal indicator bacteria at a concentrated swine feeding operation in Wake County, North Carolina, 2009-2011

    USGS Publications Warehouse

    Harden, Stephen L.; Rogers, Shane W.; Jahne, Michael A.; Shaffer, Carrie E.; Smith, Douglas G.

    2012-01-01

    Study sites were sampled for laboratory analysis of nutrients, total suspended solids (TSS), and (or) fecal indicator bacteria (FIB). Nutrient analyses included measurement of dissolved ammonia, total and dissolved ammonia + organic nitrogen, dissolved nitrate + nitrite, dissolved orthophosphate, and total phosphorus. The FIB analyses included measurement of Escherichia coli and enterococci. Samples of wastewater at the swine facility were collected from a pipe outfall from the swine housing units, two storage lagoons, and the spray fields for analysis of nutrients, TSS, and FIB. Soil samples collected from a spray field were analyzed for FIB. Monitoring locations were established for collecting discharge and water-quality data during storm events at three in-field runoff sites and two sites on the headwater stream (one upstream and one downstream) next to the swine facility. Stormflow samples at the five monitoring locations were collected for four storm events during 2009 to 2010 and analyzed for nutrients, TSS, and FIB. Monthly water samples also were collected during base-flow conditions at all four stream sites for laboratory analysis of nutrients, TSS, and (or) FIB.

  11. The impact of time and field conditions on brown bear (Ursus arctos) faecal DNA amplification

    USGS Publications Warehouse

    Murphy, M.A.; Kendall, K.C.; Robinson, A.; Waits, L.P.

    2007-01-01

    To establish longevity of faecal DNA samples under varying summer field conditions, we collected 53 faeces from captive brown bears (Ursus arctos) on a restricted vegetation diet. Each faeces was divided, and one half was placed on a warm, dry field site while the other half was placed on a cool, wet field site on Moscow Mountain, Idaho, USA. Temperature, relative humidity, and dew point data were collected on each site, and faeces were sampled for DNA extraction at <1, 3, 6, 14, 30, 45, and 60 days. Faecal DNA sample viability was assessed by attempting PCR amplification of a mitochondrial DNA (mtDNA) locus (???150 bp) and a nuclear DNA (nDNA) microsatellite locus (180-200 bp). Time in the field, temperature, and dew point impacted mtDNA and nDNA amplification success with the greatest drop in success rates occurring between 1 and 3 days. In addition, genotyping errors significantly increased over time at both field sites. Based on these results, we recommend collecting samples at frequent transect intervals and focusing sampling efforts during drier portions of the year when possible. ?? 2007 Springer Science+Business Media, Inc.

  12. Chapter A7. Biological Indicators

    USGS Publications Warehouse

    Myers, Donna N.; Wilde, Franceska D.

    2003-01-01

    The National Field Manual for the Collection of Water-Quality Data (National Field Manual) provides guidelines and standard procedures for U.S. Geological Survey (USGS) personnel who collect data used to assess the quality of the Nation's surface-water and ground-water resources. This chapter of the manual includes procedures for the (1) determination of biochemical oxygen demand using a 5-day bioassay test; (2) collection, identification, and enumeration of fecal indicator bacteria; (3) collection of samples and information on two laboratory methods for fecal indicator viruses (coliphages); and (4) collection of samples for protozoan pathogens. Each chapter of the National Field Manual is published separately and revised periodically. Newly published and revised chapters are posted on the World Wide Web on the USGS page 'National Field Manual for the Collection of Water-Quality Data.' The URL for this page is http://pubs.water.usgs.gov/twri9A/ (accessed November 25, 2003).

  13. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR REIMBURSEMENT FOR FIELD COLLECTION OF DIET SAMPLES (UA-F-23.1)

    EPA Science Inventory

    The purpose of this SOP is to provide a uniform procedure for the financial reimbursement of primary respondents for the collection of diet samples. Respondents were reimbursed for replicate food and beverage samples by type and amount collected over a 24-hour sampling period. ...

  14. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR REIMBURSEMENT FOR FIELD COLLECTION OF FOOD SAMPLES (UA-F-23.1)

    EPA Science Inventory

    The purpose of this SOP is to provide a uniform procedure for the financial reimbursement of primary respondents for the collection of diet samples. Respondents were reimbursed for replicate food and beverage samples by type and amount collected over a 24-hour sampling period. ...

  15. Variability of pesticide residues in eggplant units collected from a field trial and marketplaces in Greece.

    PubMed

    Prodhan, Mohammad Dalower Hossain; Papadakis, Emmanouil-Nikolaos; Papadopoulou-Mourkidou, Euphemia

    2018-04-01

    Variability of pesticide residues among food items is very important when assessing the risks and food safety for the consumers. Therefore, the present study was undertaken to estimate the unit-to-unit residue variability factors for eggplant. In total, 120 samples from a trial field and 142 samples from different marketplaces in Thessaloniki, Greece, were collected to estimate the variability of pesticide residues in eggplant units. They were extracted by the QuEChERS method and the residues were determined by LC-MS/MS. For the field samples, the unit-to-unit variability factors (VFs) obtained for cypermethrin and deltamethrin residues were 2.54 and 2.51, respectively. The mean residue levels of both pesticides were higher in the composite samples than in the individual samples. The average VFs for the marketplace samples was 3.89. The eggplant units exposed to pesticides were higher in residues than the non-exposed units. The variability factors obtained in the marketplace samples were higher than those in the samples collected from the field trial. A default VF value of 3 for field trials is appropriate for use when assessing the acute dietary intake but a VF for the marketplace samples should be reconsidered with a larger data. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  16. Precipitation chemistry affected by differences in location of collection sites and storage methods

    NASA Astrophysics Data System (ADS)

    Mahendrappa, M. K.

    An investigation was carried out to evaluate rigorously the possible differences in measured concentrations of hydrogen, nitrate and sulfate ions in 'bulk' precipitation samples that may be caused by variations in location of rain collectors, and duration and temperature of storage. Storage of precipitation samples, up to 1 month, both in the coldroom and in the field resulted in a significant reduction in the concentration of hydrogen ions. Only field storage caused a statistically significant reduction in the concentration of nitrate in the precipitation samples. Levels of sulfate ions were not found to be significantly affected by storage either in the field or in coldrooms. Samples collected from a rain gage located on a building roof were more acidic than those collected in open spaces in forests. Though all samples showed similar seasonal patterns in the concentrations of sulfate and nitrate, the individual values consistently differed from each other.

  17. A Mobile App for Geochemical Field Data Acquisition

    NASA Astrophysics Data System (ADS)

    Klump, J. F.; Reid, N.; Ballsun-Stanton, B.; White, A.; Sobotkova, A.

    2015-12-01

    We have developed a geochemical sampling application for use on Android tablets. This app was developed together with the Federated Archaeological Information Management Systems (FAIMS) at Macquarie University and is based on the open source FAIMS mobile platform, which was originally designed for archaeological field data collection. The FAIMS mobile platform has proved valuable for hydrogeochemical, biogeochemical, soil and rock sample collection due to the ability to customise data collection methodologies for any field research. The module we commissioned allows for using inbuilt or external GPS to locate sample points, it incorporates standard and incremental sampling names which can be easily fed into the International Geo-Sample Number (IGSN). Sampling can be documented not only in metadata, but also accompanied by photographic documentation and sketches. The module is augmented by dropdown menus for fields specific for each sample type and user defined tags. The module also provides users with an overview of all records from a field campaign in a records viewer. We also use basic mapping functionality, showing the current location, sampled points overlaid on preloaded rasters, and allows for drawing of points and simple polygons to be later exported as shape files. A particular challenge is the remoteness of the sampling locations, hundreds of kilometres away from network access. The first trial raised the issue of backup without access to the internet, so in collaboration with the FAIMS team and Solutions First, we commissioned a vehicle mounted portable server. This server box is constantly syncing with the tablets in the field via Wi-Fi, it has an uninterruptible power supply that can run for up to 45 minutes when the vehicle is turned off, and a 1TB hard drive for storage of all data and photographs. The server can be logged into via any of the field tablets or laptop to download all the data collected to date or to just view it on the server.

  18. Sampling protocol for post-landfall Deepwater Horizon oil release, Gulf of Mexico, 2010

    USGS Publications Warehouse

    Wilde, F.D.; Skrobialowski, S.C.; Hart, J.S.

    2010-01-01

    The protocols and procedures described in this report are designed to be used by U.S. Geological Survey (USGS) field teams for the collection of environmental data and samples in coastal areas affected by the 2010 Deepwater Horizon oil spill in the Gulf of Mexico. This sampling protocol focuses specifically on sampling for water, sediments, benthic invertebrates, and microorganisms (ambient bacterial populations) after shoreline arrival of petroleum-associated product on beach, barrier island, and wetland environments of the Gulf of Mexico coastal states. Deployment to sampling sites, site setup, and sample collection in these environments necessitates modifications to standard USGS sampling procedures in order to address the regulatory, logistical, and legal requirements associated with samples collected in oil-impacted coastal areas. This document, therefore, has been written as an addendum to the USGS National Field Manual for the Collection of Water-Quality Data (NFM) (http://pubs.water.usgs.gov/twri9A/), which provides the basis for training personnel in the use of standard USGS sampling protocols. The topics covered in this Gulf of Mexico oil-spill sampling protocol augment NFM protocols for field-deployment preparations, health and safety precautions, sampling and quality-assurance procedures, and decontamination requirements under potentially hazardous environmental conditions. Documentation procedures and maintenance of sample integrity by use of chain-of-custody procedures also are described in this protocol.

  19. Host status of barley to Puccinia coronata from couch grass and P. striiformis from wheat and brome

    USDA-ARS?s Scientific Manuscript database

    The pathogenicity and identity of a field sample (PcE) of crown rust fungus Puccinia coronata collected in Hungary on wild couch grass (Elytrigia repens) and of a field sample (Psb) of stripe rust (P. striiformis) collected in the Netherlands on California brome (Bromus carinatus) was studied. We fo...

  20. An efficient field and laboratory workflow for plant phylotranscriptomic projects1

    PubMed Central

    Yang, Ya; Moore, Michael J.; Brockington, Samuel F.; Timoneda, Alfonso; Feng, Tao; Marx, Hannah E.; Walker, Joseph F.; Smith, Stephen A.

    2017-01-01

    Premise of the study: We describe a field and laboratory workflow developed for plant phylotranscriptomic projects that involves cryogenic tissue collection in the field, RNA extraction and quality control, and library preparation. We also make recommendations for sample curation. Methods and Results: A total of 216 frozen tissue samples of Caryophyllales and other angiosperm taxa were collected from the field or botanical gardens. RNA was extracted, stranded mRNA libraries were prepared, and libraries were sequenced on Illumina HiSeq platforms. These included difficult mucilaginous tissues such as those of Cactaceae and Droseraceae. Conclusions: Our workflow is not only cost effective (ca. $270 per sample, as of August 2016, from tissue to reads) and time efficient (less than 50 h for 10–12 samples including all laboratory work and sample curation), but also has proven robust for extraction of difficult samples such as tissues containing high levels of secondary compounds. PMID:28337391

  1. Sample collection of ash and burned soils from the October 2007 southern California Wildfires

    USGS Publications Warehouse

    Hoefen, Todd M.; Kokaly, Raymond F.; Martin, Deborah A.; Rochester, Carlton J.; Plumlee, Geoffrey S.; Mendez, Greg; Reichard, Eric G.; Fisher, Robert N.

    2009-01-01

    Between November 2 through 9, 2007 scientists from the U.S. Geological Survey (USGS) collected samples of ash and burned soils from 28 sites in six areas burned as a result of the Southern California wildfires of October 2007, including the Harris, Witch, Santiago, Ammo, Canyon, and Grass Valley Fires. The primary goal of this sampling and analysis effort was to understand how differences in ash and burned soil composition relate to vegetation type, underlying bedrock geology, burn intensity, and residential versus wildland. Sampling sites were chosen with the input of local experts from the USGS Water Resources and Biological Resources Disciplines to help understand possible effects of the fires on water supplies, ecosystems, and endangered species. The sampling was also carried out in conjunction with detailed field analysis of the spectral reflectance characteristics of the ash, so that chemical and mineralogical characteristics of the field samples could be used to help interpret data collected as part of an airborne, hyperspectral remote-sensing survey of several of the burned areas in mid-late November, 2007.This report presents an overview of the field sampling methodologies used to collect the samples, includes representative photos of the sites sampled, and summarizes important characteristics of each of the collection sites. In this report we use the term “ash” to refer collectively to white mineral ash, which results from full combustion of vegetation and black charred organic matter from partial combustion of vegetation or other materials. These materials were found to be intermingled as a deposited residue on the soil surface following the Southern California fires of 2007.

  2. Field Geologic Observation and Sample Collection Strategies for Planetary Surface Exploration: Insights from the 2010 Desert RATS Geologist Crewmembers

    NASA Technical Reports Server (NTRS)

    Hurtado, Jose M., Jr.; Young, Kelsey; Bleacher, Jacob E.; Garry, W. Brent; Rice, James W., Jr.

    2012-01-01

    Observation is the primary role of all field geologists, and geologic observations put into an evolving conceptual context will be the most important data stream that will be relayed to Earth during a planetary exploration mission. Sample collection is also an important planetary field activity, and its success is closely tied to the quality of contextual observations. To test protocols for doing effective planetary geologic field- work, the Desert RATS(Research and Technology Studies) project deployed two prototype rovers for two weeks of simulated exploratory traverses in the San Francisco volcanic field of northern Arizona. The authors of this paper represent the geologist crew members who participated in the 2010 field test.We document the procedures adopted for Desert RATS 2010 and report on our experiences regarding these protocols. Careful consideration must be made of various issues that impact the interplay between field geologic observations and sample collection, including time management; strategies relatedtoduplicationofsamplesandobservations;logisticalconstraintson the volume and mass of samples and the volume/transfer of data collected; and paradigms for evaluation of mission success. We find that the 2010 field protocols brought to light important aspects of each of these issues, and we recommend best practices and modifications to training and operational protocols to address them. Underlying our recommendations is the recognition that the capacity of the crew to flexibly execute their activities is paramount. Careful design of mission parameters, especially field geologic protocols, is critical for enabling the crews to successfully meet their science objectives.

  3. The Polar Rock Repository: Rescuing Polar Collections for New Research

    NASA Astrophysics Data System (ADS)

    Grunow, A.

    2016-12-01

    Geological field expeditions in polar regions are logistically difficult, financially expensive and can have a significant environmental impact on pristine regions. The scarcity of outcrop in Antarctica (98% ice-covered) makes previously collected rock samples very valuable to the science community. NSF recognized the need for preserving rock, dredge, and terrestrial core samples from polar areas and created the Polar Rock Repository (PRR). The PRR collection allows for full and open access to both samples and metadata via the PRR website. In addition to the physical samples and their basic metadata, the PRR archives supporting materials from the collector, field notebooks, images of the samples, field maps, air photos, thin sections and any associated bibliography/DOI's. Many of these supporting materials are unique. More than 40,000 samples are available from the PRR for scientific analysis to researchers around the globe. Most of the samples cataloged at the PRR were collected more than 30 years ago, some more than 100 years ago. The rock samples and metadata are made available online through an advanced search engine for the PRR website. This allows scientists to "drill down" into search results using categories and look-up object fields similar to websites like Amazon. Results can be viewed in a table, downloaded as a spreadsheet, or plotted on an interactive map that supports display of satellite imagery and bathymetry layers. Samples can be requested by placing them in the `shopping cart'. These old sample collections have been repeatedly used by scientists from around the world. One data request involved locating coal deposits in Antarctica for a global compilation and another for looking at the redox state of batholithic rocks from the Antarctic Peninsula using magnetic susceptibilities of PRR rocks. Sample usage has also included non-traditional geologic studies, such as a search for monopoles in Cenozoic volcanic samples, and remote sensing/spectral imaging of Transantarctic Mountains rocks. Rescuing these collections from universities that no longer want to store the rocks or from researchers who no longer need the samples has resulted in many new publications, new proposals and enormous cost and environmental savings to the U.S. Antarctic science program.

  4. 76 FR 3119 - Availability for Exclusive, Non-Exclusive, or Partially-Exclusive Licensing of an Invention...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-19

    ... Partially-Exclusive Licensing of an Invention Concerning a Urinary Field Sampling Kit for the Determination.... Provisional Patent Application Serial No. 61/458,797, entitled ``Urinary Field Sampling Kit for the... INFORMATION: The invention relates to a urinary field sampling kit and method of its use for collecting and...

  5. Soil Gas Sampling

    EPA Pesticide Factsheets

    Field Branches Quality System and Technical Procedures: This document describes general and specific procedures, methods and considerations to be used and observed when collecting soil gas samples for field screening or laboratory analysis.

  6. Comparability of river suspended-sediment sampling and laboratory analysis methods

    USGS Publications Warehouse

    Groten, Joel T.; Johnson, Gregory D.

    2018-03-06

    Accurate measurements of suspended sediment, a leading water-quality impairment in many Minnesota rivers, are important for managing and protecting water resources; however, water-quality standards for suspended sediment in Minnesota are based on grab field sampling and total suspended solids (TSS) laboratory analysis methods that have underrepresented concentrations of suspended sediment in rivers compared to U.S. Geological Survey equal-width-increment or equal-discharge-increment (EWDI) field sampling and suspended sediment concentration (SSC) laboratory analysis methods. Because of this underrepresentation, the U.S. Geological Survey, in collaboration with the Minnesota Pollution Control Agency, collected concurrent grab and EWDI samples at eight sites to compare results obtained using different combinations of field sampling and laboratory analysis methods.Study results determined that grab field sampling and TSS laboratory analysis results were biased substantially low compared to EWDI sampling and SSC laboratory analysis results, respectively. Differences in both field sampling and laboratory analysis methods caused grab and TSS methods to be biased substantially low. The difference in laboratory analysis methods was slightly greater than field sampling methods.Sand-sized particles had a strong effect on the comparability of the field sampling and laboratory analysis methods. These results indicated that grab field sampling and TSS laboratory analysis methods fail to capture most of the sand being transported by the stream. The results indicate there is less of a difference among samples collected with grab field sampling and analyzed for TSS and concentration of fines in SSC. Even though differences are present, the presence of strong correlations between SSC and TSS concentrations provides the opportunity to develop site specific relations to address transport processes not captured by grab field sampling and TSS laboratory analysis methods.

  7. FIELD COLLECTION METHODS USED IN THE EPA NATIONAL EXPOSURE RESEARCH LABORATORY HUMAN EXPOSURE MEASUREMENT PROGRAM TO EVALUATE CHILDREN'S AGGREGATE EXPOSURE TO PESTICIDES: A TUTORIAL

    EPA Science Inventory

    A tutorial on the field sampling equipment used to collect multimedia samples.

    We conduct observational human exposure measurement studies in order to understand what chemicals people come into contact with, at what levels, what the sources of those chemicals are, and wher...

  8. Accuracy, safety, and tolerability of tissue collection by Cytosponge vs endoscopy for evaluation of eosinophilic esophagitis.

    PubMed

    Katzka, David A; Geno, Debra M; Ravi, Anupama; Smyrk, Thomas C; Lao-Sirieix, Pierre; Miremadi, Ahmed; Miramedi, Ahmed; Debiram, Irene; O'Donovan, Maria; Kita, Hirohito; Kephart, Gail M; Kryzer, Lori A; Camilleri, Michael; Alexander, Jeffrey A; Fitzgerald, Rebecca C

    2015-01-01

    Management of eosinophilic esophagitis (EoE) requires repeated endoscopic collection of mucosal samples to assess disease activity and response to therapy. An easier and less expensive means of monitoring of EoE is required. We compared the accuracy, safety, and tolerability of sample collection via Cytosponge (an ingestible gelatin capsule comprising compressed mesh attached to a string) with those of endoscopy for assessment of EoE. Esophageal tissues were collected from 20 patients with EoE (all with dysphagia, 15 with stricture, 13 with active EoE) via Cytosponge and then by endoscopy. Number of eosinophils/high-power field and levels of eosinophil-derived neurotoxin were determined; hematoxylin-eosin staining was performed. We compared the adequacy, diagnostic accuracy, safety, and patient preference for sample collection via Cytosponge vs endoscopy procedures. All 20 samples collected by Cytosponge were adequate for analysis. By using a cutoff value of 15 eosinophils/high power field, analysis of samples collected by Cytosponge identified 11 of the 13 individuals with active EoE (83%); additional features such as abscesses were also identified. Numbers of eosinophils in samples collected by Cytosponge correlated with those in samples collected by endoscopy (r = 0.50, P = .025). Analysis of tissues collected by Cytosponge identified 4 of the 7 patients without active EoE (57% specificity), as well as 3 cases of active EoE not identified by analysis of endoscopy samples. Including information on level of eosinophil-derived neurotoxin did not increase the accuracy of diagnosis. No complications occurred during the Cytosponge procedure, which was preferred by all patients, compared with endoscopy. In a feasibility study, the Cytosponge is a safe and well-tolerated method for collecting near mucosal specimens. Analysis of numbers of eosinophils/high-power field identified patients with active EoE with 83% sensitivity. Larger studies are needed to establish the efficacy and safety of this method of esophageal tissue collection. ClinicalTrials.gov number: NCT01585103. Copyright © 2015 AGA Institute. Published by Elsevier Inc. All rights reserved.

  9. Chapter A5. Processing of Water Samples

    USGS Publications Warehouse

    Wilde, Franceska D.; Radtke, Dean B.; Gibs, Jacob; Iwatsubo, Rick T.

    1999-01-01

    The National Field Manual for the Collection of Water-Quality Data (National Field Manual) describes protocols and provides guidelines for U.S. Geological Survey (USGS) personnel who collect data used to assess the quality of the Nation's surface-water and ground-water resources. This chapter addresses methods to be used in processing water samples to be analyzed for inorganic and organic chemical substances, including the bottling of composite, pumped, and bailed samples and subsamples; sample filtration; solid-phase extraction for pesticide analyses; sample preservation; and sample handling and shipping. Each chapter of the National Field Manual is published separately and revised periodically. Newly published and revised chapters will be announced on the USGS Home Page on the World Wide Web under 'New Publications of the U.S. Geological Survey.' The URL for this page is http:/ /water.usgs.gov/lookup/get?newpubs.

  10. Field and laboratory data describing physical and chemical characteristics of metal-contaminated flood-plain deposits downstream from Lead, west-central South Dakota

    USGS Publications Warehouse

    Marron, D.C.

    1988-01-01

    Samples from metal-contaminated flood-plain sediments at 9 sites downstream from Lead, in west-central South Dakota, were collected during the summers of 1985-87 to characterize aspects of the sedimentology, chemistry, and geometry of a deposit that resulted from the discharge of a large volume of mining wastes into a river system. Field and laboratory data include stratigraphic descriptions, chemical contents and grain-size distributions of samples, and surveyed flood-plain positions of samples. This report describes sampling-site locations, and methods of sample collection and preservation, and subsequent laboratory analysis. Field and laboratory data are presented in 4 figures and 11 tables in the ' Supplemental Data ' section at the back of the report. (USGS)

  11. Lead in rice: analysis of baseline lead levels in market and field collected rice grains.

    PubMed

    Norton, Gareth J; Williams, Paul N; Adomako, Eureka E; Price, Adam H; Zhu, Yongguan; Zhao, Fang-Jie; McGrath, Steve; Deacon, Claire M; Villada, Antia; Sommella, Alessia; Lu, Ying; Ming, Lei; De Silva, P Mangala C S; Brammer, Hugh; Dasgupta, Tapash; Islam, M Rafiqul; Meharg, Andrew A

    2014-07-01

    In a large scale survey of rice grains from markets (13 countries) and fields (6 countries), a total of 1578 rice grain samples were analysed for lead. From the market collected samples, only 0.6% of the samples exceeded the Chinese and EU limit of 0.2 μg g(-1) lead in rice (when excluding samples collected from known contaminated/mine impacted regions). When evaluating the rice grain samples against the Food and Drug Administration's (FDA) provisional total tolerable intake (PTTI) values for children and pregnant women, it was found that only people consuming large quantities of rice were at risk of exceeding the PTTI from rice alone. Furthermore, 6 field experiments were conducted to evaluate the proportion of the variation in lead concentration in rice grains due to genetics. A total of 4 of the 6 field experiments had significant differences between genotypes, but when the genotypes common across all six field sites were assessed, only 4% of the variation was explained by genotype, with 9.5% and 11% of the variation explained by the environment and genotype by environment interaction respectively. Further work is needed to identify the sources of lead contamination in rice, with detailed information obtained on the locations and environments where the rice is sampled, so that specific risk assessments can be performed. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Review of Trace-Element Field-Blank Data Collected for the California Groundwater Ambient Monitoring and Assessment (GAMA) Program, May 2004-January 2008

    USGS Publications Warehouse

    Olsen, Lisa D.; Fram, Miranda S.; Belitz, Kenneth

    2010-01-01

    Trace-element quality-control samples (for example, source-solution blanks, field blanks, and field replicates) were collected as part of a statewide investigation of groundwater quality in California, known as the Priority Basins Project of the Groundwater Ambient Monitoring and Assessment (GAMA) Program. The GAMA Priority Basins Project is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB) to assess and monitor the quality of groundwater resources used for drinking-water supply and to improve public knowledge of groundwater quality in California. Trace-element field blanks were collected to evaluate potential bias in the corresponding environmental data. Bias in the environmental data could result from contamination in the field during sample collection, from the groundwater coming into contact with contaminants on equipment surfaces or from other sources, or from processing, shipping, or analyzing the samples. Bias affects the interpretation of environmental data, particularly if any constituents are present solely as a result of extrinsic contamination that would have otherwise been absent from the groundwater that was sampled. Field blanks were collected, analyzed, and reviewed to identify and quantify extrinsic contamination bias. Data derived from source-solution blanks and laboratory quality-control samples also were considered in evaluating potential contamination bias. Eighty-six field-blank samples collected from May 2004 to January 2008 were analyzed for the concentrations of 25 trace elements. Results from these field blanks were used to interpret the data for the 816 samples of untreated groundwater collected over the same period. Constituents analyzed were aluminum (Al), antimony (Sb), arsenic (As), barium (Ba), beryllium (Be), boron (B), cadmium (Cd), chromium (Cr), cobalt (Co), copper (Cu), iron (Fe), lead (Pb), lithium (Li), manganese (Mn), mercury (Hg), molybdenum (Mo), nickel (Ni), selenium (Se), silver (Ag), strontium (Sr), thallium (Tl), tungsten (W), uranium (U), vanadium (V), and zinc (Zn). The detection frequency and the 90th percentile concentration at greater than 90 percent confidence were determined from the field-blank data for each trace element, and these results were compared to each constituent's long-term method detection level (LT-MDL) to determine whether a study reporting level (SRL) was necessary to ensure that no more than 10 percent of the detections in groundwater samples could be attributed solely to contamination bias. Only two of the trace elements analyzed, Li and Se, had zero detections in the 86 field blanks. Ten other trace elements (Sb, As, Be, B, Cd, Co, Mo, Ag, Tl, and U) were detected in fewer than 5 percent of the field blanks. The field-blank results for these constituents did not necessitate establishing SRLs. Of the 13 constituents that were detected in more than 5 percent of the field blanks, six (Al, Ba, Cr, Mn, Hg, and V) had field-blank results that indicated a need for SRLs that were at or below the highest laboratory reporting levels (LRL) used during the sampling period; these SRLs were needed for concentrations between the LT-MDLs and LRLs. The other seven constituents with detection frequencies above 5 percent (Cu, Fe, Pb, Ni, Sr, W, and Zn) had field-blank results that necessitated SRLs greater than the highest LRLs used during the study period. SRLs for these seven constituents, each set at the 90th percentile of their concentrations in the field blanks, were at least an order of magnitude below the regulatory thresholds established for drinking water for health or aesthetic purposes; therefore, reporting values below the SRLs as less than or equal to (=) the measured value would not prevent the identification of values greater than the drinking-water thresholds. The SRLs and drinking-water thresholds, respectively, for these 7 trace elements are Cu (1.7 ?g/L and 1,300

  13. Estimating occupancy and abundance of stream amphibians using environmental DNA from filtered water samples

    USGS Publications Warehouse

    Pilliod, David S.; Goldberg, Caren S.; Arkle, Robert S.; Waits, Lisette P.

    2013-01-01

    Environmental DNA (eDNA) methods for detecting aquatic species are advancing rapidly, but with little evaluation of field protocols or precision of resulting estimates. We compared sampling results from traditional field methods with eDNA methods for two amphibians in 13 streams in central Idaho, USA. We also evaluated three water collection protocols and the influence of sampling location, time of day, and distance from animals on eDNA concentration in the water. We found no difference in detection or amount of eDNA among water collection protocols. eDNA methods had slightly higher detection rates than traditional field methods, particularly when species occurred at low densities. eDNA concentration was positively related to field-measured density, biomass, and proportion of transects occupied. Precision of eDNA-based abundance estimates increased with the amount of eDNA in the water and the number of replicate subsamples collected. eDNA concentration did not vary significantly with sample location in the stream, time of day, or distance downstream from animals. Our results further advance the implementation of eDNA methods for monitoring aquatic vertebrates in stream habitats.

  14. NHEXAS PHASE I REGION 5 STUDY--STANDARD OPERATING PROCEDURE--SAMPLE SHIPPING PROCEDURES (RTI/ACS-AP-209-083)

    EPA Science Inventory

    This procedure summarizes the sample shipping procedures that have been described in the individual NHEXAS sample collection protocols. This procedure serves as a quick reference tool for the field staff when samples are prepared for shipment at the field lab/staging area. For ea...

  15. Synthetic turf field investigation in Connecticut.

    PubMed

    Simcox, Nancy J; Bracker, Anne; Ginsberg, Gary; Toal, Brian; Golembiewski, Brian; Kurland, Tara; Hedman, Curtis

    2011-01-01

    The primary purpose of this study was to characterize the concentrations of volatile organic compounds (VOC), semivolatile organic compounds (SVOC), rubber-related chemicals such as benzothiazole (BZT) and nitrosamine, and particulate matter (PM(10)) in air at synthetic turf crumb rubber fields. Both new and older fields were evaluated under conditions of active use. Three types of fields were targeted: four outdoor crumb rubber fields, one indoor facility with crumb rubber turf, and an outdoor natural grass field. Background samples were collected at each field on grass. Personal air sampling was conducted for VOC, BZT, nitrosamines, and other chemicals. Stationary air samples were collected at different heights to assess the vertical profile of release. Air monitoring for PM(10) was conducted at one height. Bulk samples of turf grass and crumb rubber were analyzed, and meteorological data were recorded. Results showed that personal concentrations were higher than stationary concentrations and were higher on turf than in background samples for certain VOC. In some cases, personal VOC concentrations from natural grass fields were as high as those on turf. Naphthalene, BZT, and butylated hydroxytoluene (BHT) were detected in greater concentration at the indoor field compared to the outdoor fields. Nitrosamine air levels were below reporting levels. PM(10) air concentrations were not different between on-field and upwind locations. All bulk lead (Pb) samples were below the public health target of 400 ppm. More research is needed to better understand air quality at indoor facilities. These field investigation data were incorporated into a separate human health risk assessment.

  16. Installation Restoration Program, Phase II (Stage 2-1). Volume 2.

    DTIC Science & Technology

    1985-05-01

    Worthington OH PAGES: 89 SOURCE: Radian Library COMMENTS: General manual for well drilling, sample collection . Includes good elementary background. FIRST... Collected from the Base Industrial and Domestic Waste Water Treatment Plants and Field * Sampling Data PAGES: 75 p. SOURCE: Capt. Mario Ierarti * COMMENTS...Analytical results for samples collected from the * base industrial and domestic wastewater treatment plants have been included. RADIAN FIRST AUTHOR

  17. Selected Water-Quality Data from the Cedar River and Cedar Rapids Well Fields, Cedar Rapids, Iowa, 1999-2005

    USGS Publications Warehouse

    Littin, Gregory R.; Schnoebelen, Douglas J.

    2010-01-01

    The Cedar River alluvial aquifer is the primary source of municipal water in the Cedar Rapids, Iowa area. Municipal wells are completed in the alluvial aquifer at approximately 40 to 80 feet deep. The City of Cedar Rapids and the U.S. Geological Survey have been conducting a cooperative study of the groundwater-flow system and water quality near the well fields since 1992. Previous cooperative studies between the City of Cedar Rapids and the U.S. Geological Survey have documented hydrologic and water-quality data, geochemistry, and groundwater models. Water-quality samples were collected for studies involving well field monitoring, trends, source-water protection, groundwater geochemistry, evaluation of surface and ground-water interaction, assessment of pesticides in groundwater and surface water, and to evaluate water quality near a wetland area in the Seminole well field. Typical water-quality analyses included major ions (boron, bromide, calcium, chloride, fluoride, iron, magnesium, manganese, potassium, silica, sodium, and sulfate), nutrients (ammonia as nitrogen, nitrite as nitrogen, nitrite plus nitrate as nitrogen, and orthophosphate as phosphorus), dissolved organic carbon, and selected pesticides including two degradates of the herbicide atrazine. In addition, two synoptic samplings included analyses of additional pesticide degradates in water samples. Physical field parameters (alkalinity, dissolved oxygen, pH, specific conductance and water temperature) were recorded with each water sample collected. This report presents the results of water quality data-collection activities from January 1999 through December 2005. Methods of data collection, quality-assurance samples, water-quality analyses, and statistical summaries are presented. Data include the results of water-quality analyses from quarterly and synoptic sampling from monitoring wells, municipal wells, and the Cedar River.

  18. The role of field auditing in environmental quality assurance management.

    PubMed

    Claycomb, D R

    2000-01-01

    Environmental data quality improvement continues to focus on analytical laboratoryperformance with little, if any, attention given to improving the performance of field consultants responsible for sample collection. Many environmental professionals often assume that the primary opportunity for data error lies within the activities conducted by the laboratory. Experience in the evaluation of environmental data and project-wide quality assurance programs indicates that an often-ignored factor affecting environmental data quality is the manner in which a sample is acquired and handled in the field. If a sample is not properly collected, preserved, stored, and transported in the field, even the best laboratory practices and analytical methods cannot deliver accurate and reliable data (i.e., bad data in equals bad data out). Poor quality environmental data may result in inappropriate decisions regarding site characterization and remedial action. Field auditing is becoming an often-employed technique for examining the performance of the environmental sampling field team and how their performance may affect data quality. The field audits typically focus on: (1) verifying that field consultants adhere to project control documents (e.g., Work Plans and Standard Operating Procedures [SOPs]) during field operations; (2) providing third-party independent assurance that field procedures, quality assurance/ quality control (QA/QC)protocol, and field documentation are sufficient to produce data of satisfactory quality; (3) providing a defense in the event that field procedures are called into question; and (4) identifying ways to reduce sampling costs. Field audits are typically most effective when performed on a surprise basis; that is, the sampling contractor may be aware that a field audit will be conducted during some phase of sampling activities but is not informed of the specific day(s) that the audit will be conducted. The audit also should be conducted early on in the sampling program such that deficiencies noted during the audit can be addressed before the majority of field activities have been completed. A second audit should be performed as a follow-up to confirm that the recommended changes have been implemented. A field auditor is assigned to the project by matching, as closely as possible, the auditor's experience with the type of field activities being conducted. The auditor uses a project-specific field audit checklist developed from key information contained in project control documents. Completion of the extensive audit checklist during the audit focuses the auditor on evaluating each aspect of field activities being performed. Rather than examine field team performance after sampling, a field auditor can do so while the samples are being collected and can apply real-time corrective action as appropriate. As a result of field audits, responsible parties often observe vast improvements in their consultant's field procedures and, consequently, receive more reliable and representative field data at a lower cost. The cost savings and improved data quality that result from properly completed field audits make the field auditing process both cost-effective and functional.

  19. Scientific guidelines for preservation of samples collected from Mars

    NASA Technical Reports Server (NTRS)

    Gooding, James L. (Editor)

    1990-01-01

    The maximum scientific value of Martian geologic and atmospheric samples is retained when the samples are preserved in the conditions that applied prior to their collection. Any sample degradation equates to loss of information. Based on detailed review of pertinent scientific literature, and advice from experts in planetary sample analysis, number values are recommended for key parameters in the environmental control of collected samples with respect to material contamination, temperature, head-space gas pressure, ionizing radiation, magnetic fields, and acceleration/shock. Parametric values recommended for the most sensitive geologic samples should also be adequate to preserve any biogenic compounds or exobiological relics.

  20. Collecting, archiving and processing DNA from wildlife samples using FTA® databasing paper

    PubMed Central

    Smith, LM; Burgoyne, LA

    2004-01-01

    Background Methods involving the analysis of nucleic acids have become widespread in the fields of traditional biology and ecology, however the storage and transport of samples collected in the field to the laboratory in such a manner to allow purification of intact nucleic acids can prove problematical. Results FTA® databasing paper is widely used in human forensic analysis for the storage of biological samples and for purification of nucleic acids. The possible uses of FTA® databasing paper in the purification of DNA from samples of wildlife origin were examined, with particular reference to problems expected due to the nature of samples of wildlife origin. The processing of blood and tissue samples, the possibility of excess DNA in blood samples due to nucleated erythrocytes, and the analysis of degraded samples were all examined, as was the question of long term storage of blood samples on FTA® paper. Examples of the end use of the purified DNA are given for all protocols and the rationale behind the processing procedures is also explained to allow the end user to adjust the protocols as required. Conclusions FTA® paper is eminently suitable for collection of, and purification of nucleic acids from, biological samples from a wide range of wildlife species. This technology makes the collection and storage of such samples much simpler. PMID:15072582

  1. Corrective Action Investigation Plan for Corrective Action Unit 428: Area 3 Septic Waste Systems 1 and 5, Tonopah Test Range, Nevada, REVISION 0, march 1999

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    ITLV.

    1999-03-01

    The Corrective Action Investigation Plan for Corrective Action Unit 428, Area 3 Septic Waste Systems 1 and 5, has been developed in accordance with the Federal Facility Agreement and Consent Order that was agreed to by the U. S. Department of Energy, Nevada Operations Office; the State of Nevada Division of Environmental Protection; and the U. S. Department of Defense. Corrective Action Unit 428 consists of Corrective Action Sites 03- 05- 002- SW01 and 03- 05- 002- SW05, respectively known as Area 3 Septic Waste System 1 and Septic Waste System 5. This Corrective Action Investigation Plan is used inmore » combination with the Work Plan for Leachfield Corrective Action Units: Nevada Test Site and Tonopah Test Range, Nevada , Rev. 1 (DOE/ NV, 1998c). The Leachfield Work Plan was developed to streamline investigations at leachfield Corrective Action Units by incorporating management, technical, quality assurance, health and safety, public involvement, field sampling, and waste management information common to a set of Corrective Action Units with similar site histories and characteristics into a single document that can be referenced. This Corrective Action Investigation Plan provides investigative details specific to Corrective Action Unit 428. A system of leachfields and associated collection systems was used for wastewater disposal at Area 3 of the Tonopah Test Range until a consolidated sewer system was installed in 1990 to replace the discrete septic waste systems. Operations within various buildings at Area 3 generated sanitary and industrial wastewaters potentially contaminated with contaminants of potential concern and disposed of in septic tanks and leachfields. Corrective Action Unit 428 is composed of two leachfield systems in the northern portion of Area 3. Based on site history collected to support the Data Quality Objectives process, contaminants of potential concern for the site include oil/ diesel range total petroleum hydrocarbons, and Resource Conservation and Recovery Act characteristic volatile organic compounds, semivolatile organic compounds, and metals. A limited number of samples will be analyzed for gamma- emitting radionuclides and isotopic uranium from four of the septic tanks and if radiological field screening levels are exceeded. Additional samples will be analyzed for geotechnical and hydrological properties and a bioassessment may be performed. The technical approach for investigating this Corrective Action Unit consists of the following activities: Perform video surveys of the discharge and outfall lines. Collect samples of material in the septic tanks. Conduct exploratory trenching to locate and inspect subsurface components. Collect subsurface soil samples in areas of the collection system including the septic tanks and outfall end of distribution boxes. Collect subsurface soil samples underlying the leachfield distribution pipes via trenching. Collect surface and near- surface samples near potential locations of the Acid Sewer Outfall if Septic Waste System 5 Leachfield cannot be located. Field screen samples for volatile organic compounds, total petroleum hydrocarbons, and radiological activity. Drill boreholes and collect subsurface soil samples if required. Analyze samples for total volatile organic compounds, total semivolatile organic compounds, total Resource Conservation and Recovery Act metals, and total petroleum hydrocarbons (oil/ diesel range organics). Limited number of samples will be analyzed for gamma- emitting radionuclides and isotopic uranium from particular septic tanks and if radiological field screening levels are exceeded. Collect samples from native soils beneath the distribution system and analyze for geotechnical/ hydrologic parameters. Collect and analyze bioassessment samples at the discretion of the Site Supervisor if total petroleum hydrocarbons exceed field- screening levels.« less

  2. Long-Term Ecological Monitoring Field Sampling Plan for 2007

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    T. Haney

    2007-07-31

    This field sampling plan describes the field investigations planned for the Long-Term Ecological Monitoring Project at the Idaho National Laboratory Site in 2007. This plan and the Quality Assurance Project Plan for Waste Area Groups 1, 2, 3, 4, 5, 6, 7, 10, and Removal Actions constitute the sampling and analysis plan supporting long-term ecological monitoring sampling in 2007. The data collected under this plan will become part of the long-term ecological monitoring data set that is being collected annually. The data will be used t determine the requirements for the subsequent long-term ecological monitoring. This plan guides the 2007more » investigations, including sampling, quality assurance, quality control, analytical procedures, and data management. As such, this plan will help to ensure that the resulting monitoring data will be scientifically valid, defensible, and of known and acceptable quality.« less

  3. Within-field variability of plant and soil parameters

    NASA Technical Reports Server (NTRS)

    Ulaby, F. T. (Principal Investigator); Brisco, B.; Dobson, C.

    1981-01-01

    The variability of ground truth data collected for vegetation experiments was investigated. Two fields of wheat and one field of corn were sampled on two different dates. The variability of crop and soil parameters within a field, between two fields of the same type, and within a field over time were compared statistically. The number of samples from each test site required in order to be able to determine with confidence the mean and standard deviations for a given variable was determined. Eight samples were found to be adequate for plant height determinations, while twenty samples were required for plant moisture and soil moisture characterization. Eighteen samples were necessary for detecting within field variability over time and for between field variability for the same crop. The necessary sample sites vary according to the physiological growth stage of the crop and recent weather events that affect the moisture and/or height characteristics of the field in question.

  4. U.S. Geological Survey nutrient preservation experiment; nutrient concentration data for surface-, ground-, and municipal-supply water samples and quality-assurance samples

    USGS Publications Warehouse

    Patton, Charles J.; Truitt, Earl P.

    1995-01-01

    This report is a compilation of analytical results from a study conducted at the U.S. Geological Survey, National Water Quality Laboratory (NWQL) in 1992 to assess the effectiveness of three field treatment protocols to stabilize nutrient concentra- tions in water samples stored for about 1 month at 4C. Field treatments tested were chilling, adjusting sample pH to less than 2 with sulfuric acid and chilling, and adding 52 milligrams of mercury (II) chloride per liter of sample and chilling. Field treatments of samples collected for determination of ammonium, nitrate plus nitrite, nitrite, dissolved Kjeldahl nitrogen, orthophosphate, and dissolved phosphorus included 0.45-micrometer membrane filtration. Only total Kjeldahl nitrogen and total phosphorus were determined in unfiltered samples. Data reported here pertain to water samples collected in April and May 1992 from 15 sites within the continental United States. Also included in this report are analytical results for nutrient concentrations in synthetic reference samples that were analyzed concurrently with real samples.

  5. Seedling Disease Survey in Michigan

    USDA-ARS?s Scientific Manuscript database

    Stand establishment and persistence continue to be problems for Michigan growers. To determine the extent and severity of the problem, a survey of diseased seedlings from Michigan fields was initiated in 2008. Samples were collected of diseased seedlings for two years. In 2008, samples were collecte...

  6. Protocol to obtain targeted transcript sequence data from snake venom samples collected in the Colombian field.

    PubMed

    Fonseca, Alejandra; Renjifo-Ibáñez, Camila; Renjifo, Juan Manuel; Cabrera, Rodrigo

    2018-03-21

    Snake venoms are a mixture of different molecules that can be used in the design of drugs for various diseases. The study of these venoms has relied on strategies that use complete venom extracted from animals in captivity or from venom glands that require the sacrifice of the animals. Colombia, a country with political and geographical conflicts has difficult access to certain regions. A strategy that can prevent the sacrifice of animals and could allow the study of samples collected in the field is necessary. We report the use of lyophilized venom from Crotalus durissus cumanensis as a model to test, for the first time, a protocol for the amplification of complete toxins from Colombian venom samples collected in the field. In this protocol, primers were designed from conserved region from Crotalus sp. mRNA and EST regions to maximize the likelihood of coding sequence amplification. We obtained the sequences of Metalloproteinases II, Disintegrins, Disintegrin-Like, Phospholipases A 2, C-type Lectins and Serine proteinases from Crotalus durissus cumanensis and compared them to different Crotalus sp sequences available on databases obtaining concordance between the toxins amplified and those reported. Our strategy allows the use of lyophilized venom to obtain complete toxin sequences from samples collected in the field and the study of poorly characterized venoms in challenging environments. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. Synchronous in-field application of life-detection techniques in planetary analog missions

    NASA Astrophysics Data System (ADS)

    Amador, Elena S.; Cable, Morgan L.; Chaudry, Nosheen; Cullen, Thomas; Gentry, Diana; Jacobsen, Malene B.; Murukesan, Gayathri; Schwieterman, Edward W.; Stevens, Adam H.; Stockton, Amanda; Yin, Chang; Cullen, David C.; Geppert, Wolf

    2015-02-01

    Field expeditions that simulate the operations of robotic planetary exploration missions at analog sites on Earth can help establish best practices and are therefore a positive contribution to the planetary exploration community. There are many sites in Iceland that possess heritage as planetary exploration analog locations and whose environmental extremes make them suitable for simulating scientific sampling and robotic operations. We conducted a planetary exploration analog mission at two recent lava fields in Iceland, Fimmvörðuháls (2010) and Eldfell (1973), using a specially developed field laboratory. We tested the utility of in-field site sampling down selection and tiered analysis operational capabilities with three life detection and characterization techniques: fluorescence microscopy (FM), adenine-triphosphate (ATP) bioluminescence assay, and quantitative polymerase chain reaction (qPCR) assay. The study made use of multiple cycles of sample collection at multiple distance scales and field laboratory analysis using the synchronous life-detection techniques to heuristically develop the continuing sampling and analysis strategy during the expedition. Here we report the operational lessons learned and provide brief summaries of scientific data. The full scientific data report will follow separately. We found that rapid in-field analysis to determine subsequent sampling decisions is operationally feasible, and that the chosen life detection and characterization techniques are suitable for a terrestrial life-detection field mission. In-field analysis enables the rapid obtainment of scientific data and thus facilitates the collection of the most scientifically relevant samples within a single field expedition, without the need for sample relocation to external laboratories. The operational lessons learned in this study could be applied to future terrestrial field expeditions employing other analytical techniques and to future robotic planetary exploration missions.

  8. The Federal Cylinder Project: A Guide to Field Cylinder Collections in Federal Agencies. Volume 1, Introduction and Inventory.

    ERIC Educational Resources Information Center

    Brady, Erika; And Others

    Volume one of a multivolume catalog inventories 247 federal agency collections of wax cylinder recordings made by early ethnographers during 5 decades (1890-1941) of field work with Native American, traditional American, and world cultures. Native American music, chants, and linguistic samples comprise the majority of the collection. In addition…

  9. Evaluation of field sampling and preservation methods for strontium-90 in ground water at the Idaho National Engineering Laboratory, Idaho

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cecil, L.D.; Knobel, L.L.; Wegner, S.J.

    1989-09-01

    From 1952 to 1988, about 140 curies of strontium-90 have been discharged in liquid waste to disposal ponds and wells at the INEL (Idaho National Engineering Laboratory). The US Geological Survey routinely samples ground water from the Snake River Plain aquifer and from discontinuous perched-water zones for selected radionuclides, major and minor ions, and chemical and physical characteristics. Water samples for strontium-90 analyses collected in the field are unfiltered and preserved to an approximate 2-percent solution with reagent-grade hydrochloric acid. Water from four wells completed in the Snake River Plain aquifer was sampled as part of the US Geological Survey'smore » quality-assurance program to evaluate the effect of filtration and preservation methods on strontium-90 concentrations in ground water at the INEL. The wells were selected for sampling on the basis of historical concentrations of strontium-90 in ground water. Water from each well was filtered through either a 0.45- or a 0.1-micrometer membrane filter; unfiltered samples also were collected. Two sets of filtered and two sets of unfiltered water samples were collected at each well. One set of water samples was preserved in the field to an approximate 2-percent solution with reagent-grade hydrochloric acid and the other set of samples was not acidified. 13 refs., 2 figs., 6 tabs.« less

  10. Tools and Technologies Needed for Conducting Planetary Field Geology While On EVA: Insights from the 2010 Desert RATS Geologist Crewmembers

    NASA Technical Reports Server (NTRS)

    Young, Kelsey; Hurtado, Jose M., Jr.; Bleacher, Jacob E.; Garry, W. Brent; Bleisath, Scott; Buffington, Jesse; Rice, James W., Jr.

    2011-01-01

    Observation is the primary role of all field geologists, and geologic observations put into an evolving conceptual context will be the most important data stream that will be relayed to Earth during a planetary exploration mission. Sample collection is also an important planetary field activity, and its success is closely tied to the quality of contextual observations. To test protocols for doing effective planetary geologic fieldwork, the Desert RATS (Research and Technology Studies) project deployed two prototype rovers for two weeks of simulated exploratory traverses in the San Francisco volcanic field of northern Arizona. The authors of this paper represent the geologist crewmembers who participated in the 2010 field test. We document the procedures adopted for Desert RATS 2010 and report on our experiences regarding these protocols. Careful consideration must be made of various issues that impact the interplay between field geologic observations and sample collection, including time management; strategies related to duplication of samples and observations; logistical constraints on the volume and mass of samples and the volume/transfer of data collected; and paradigms for evaluation of mission success. We find that the 2010 field protocols brought to light important aspects of each of these issues, and we recommend best practices and modifications to training and operational protocols to address them. Underlying our recommendations is the recognition that the capacity of the crew to "flexibly execute" their activities is paramount. Careful design of mission parameters, especially field geologic protocols, is critical for enabling the crews to successfully meet their science objectives.

  11. Human breath metabolomics using an optimized noninvasive exhaled breath condensate sampler

    PubMed Central

    Zamuruyev, Konstantin O.; Aksenov, Alexander A.; Pasamontes, Alberto; Brown, Joshua F.; Pettit, Dayna R.; Foutouhi, Soraya; Weimer, Bart C.; Schivo, Michael; Kenyon, Nicholas J.; Delplanque, Jean-Pierre; Davis, Cristina E.

    2017-01-01

    Exhaled breath condensate (EBC) analysis is a developing field with tremendous promise to advance personalized, non-invasive health diagnostics as new analytical instrumentation platforms and detection methods are developed. Multiple commercially-available and researcher-built experimental samplers are reported in the literature. However, there is very limited information available to determine an effective breath sampling approach, especially regarding the dependence of breath sample metabolomic content on the collection device design and sampling methodology. This lack of an optimal standard procedure results in a range of reported results that are sometimes contradictory. Here, we present a design of a portable human EBC sampler optimized for collection and preservation of the rich metabolomic content of breath. The performance of the engineered device is compared to two commercially available breath collection devices: the RTube™ and TurboDECCS. A number of design and performance parameters are considered, including: condenser temperature stability during sampling, collection efficiency, condenser material choice, and saliva contamination in the collected breath samples. The significance of the biological content of breath samples, collected with each device, is evaluated with a set of mass spectrometry methods and was the primary factor for evaluating device performance. The design includes an adjustable mass-size threshold for aerodynamic filtering of saliva droplets from the breath flow. Engineering an inexpensive device that allows efficient collection of metalomic-rich breath samples is intended to aid further advancement in the field of breath analysis for non-invasive health diagnostic. EBC sampling from human volunteers was performed under UC Davis IRB protocol 63701-3 (09/30/2014-07/07/2017). PMID:28004639

  12. Human breath metabolomics using an optimized non-invasive exhaled breath condensate sampler.

    PubMed

    Zamuruyev, Konstantin O; Aksenov, Alexander A; Pasamontes, Alberto; Brown, Joshua F; Pettit, Dayna R; Foutouhi, Soraya; Weimer, Bart C; Schivo, Michael; Kenyon, Nicholas J; Delplanque, Jean-Pierre; Davis, Cristina E

    2016-12-22

    Exhaled breath condensate (EBC) analysis is a developing field with tremendous promise to advance personalized, non-invasive health diagnostics as new analytical instrumentation platforms and detection methods are developed. Multiple commercially-available and researcher-built experimental samplers are reported in the literature. However, there is very limited information available to determine an effective breath sampling approach, especially regarding the dependence of breath sample metabolomic content on the collection device design and sampling methodology. This lack of an optimal standard procedure results in a range of reported results that are sometimes contradictory. Here, we present a design of a portable human EBC sampler optimized for collection and preservation of the rich metabolomic content of breath. The performance of the engineered device is compared to two commercially available breath collection devices: the RTube ™ and TurboDECCS. A number of design and performance parameters are considered, including: condenser temperature stability during sampling, collection efficiency, condenser material choice, and saliva contamination in the collected breath samples. The significance of the biological content of breath samples, collected with each device, is evaluated with a set of mass spectrometry methods and was the primary factor for evaluating device performance. The design includes an adjustable mass-size threshold for aerodynamic filtering of saliva droplets from the breath flow. Engineering an inexpensive device that allows efficient collection of metalomic-rich breath samples is intended to aid further advancement in the field of breath analysis for non-invasive health diagnostic. EBC sampling from human volunteers was performed under UC Davis IRB protocol 63701-3 (09/30/2014-07/07/2017).

  13. COLLECTING URINE SAMPLES FROM YOUNG CHILDREN USING COTTON GAUZE FOR PESTICIDE STUDIES

    EPA Science Inventory

    To estimate pesticide exposure, urine samples are often needed to analyze pesticide metabolites. However, this is difficult for children wearing diapers because simple and feasible techniques suitable for field collection are not available. The objectives of this study were to t...

  14. COLLECTING URINE SAMPLES FROM YOUNG CHILDREN USING GAUZE FOR PESTICIDE STUDIES

    EPA Science Inventory

    To estimate pesticide exposure, urine samples are often needed to analyze pesticide metabolites. However, this is difficult for children wearing diapers because simple and feasible techniques suitable for field collection are not available. The objectives of this study were to te...

  15. Improved discovery of NEON data and samples though vocabularies, workflows, and web tools

    NASA Astrophysics Data System (ADS)

    Laney, C. M.; Elmendorf, S.; Flagg, C.; Harris, T.; Lunch, C. K.; Gulbransen, T.

    2017-12-01

    The National Ecological Observatory Network (NEON) is a continental-scale ecological observation facility sponsored by the National Science Foundation and operated by Battelle. NEON supports research on the impacts of invasive species, land use change, and environmental change on natural resources and ecosystems by gathering and disseminating a full suite of observational, instrumented, and airborne datasets from field sites across the U.S. NEON also collects thousands of samples from soil, water, and organisms every year, and partners with numerous institutions to analyze and archive samples. We have developed numerous new technologies to support processing and discovery of this highly diverse collection of data. These technologies include applications for data collection and sample management, processing pipelines specific to each collection system (field observations, installed sensors, and airborne instruments), and publication pipelines. NEON data and metadata are discoverable and downloadable via both a public API and data portal. We solicit continued engagement and advice from the informatics and environmental research communities, particularly in the areas of data versioning, usability, and visualization.

  16. Gas dispersion concentration of trace inorganic contaminants from fuel gas and analysis using head-column field-amplified sample stacking capillary electrophoresis.

    PubMed

    Yang, Jianmin; Li, Hai-Fang; Li, Meilan; Lin, Jin-Ming

    2012-08-21

    The presence of inorganic elements in fuel gas generally accelerates the corrosion and depletion of materials used in the fuel gas industry, and even leads to serious accidents. For identification of existing trace inorganic contaminants in fuel gas in a portable way, a highly efficient gas-liquid sampling collection system based on gas dispersion concentration is introduced in this work. Using the constructed dual path gas-liquid collection setup, inorganic cations and anions were simultaneously collected from real liquefied petroleum gas (LPG) and analyzed by capillary electrophoresis (CE) with indirect UV absorbance detection. The head-column field-amplified sample stacking technique was applied to improve the detection limits to 2-25 ng mL(-1). The developed collection and analytical methods have successfully determined existing inorganic contaminants in a real LPG sample in the range of 4.59-138.69 μg m(-3). The recoveries of cations and anions with spiked LPG samples were between 83.98 and 105.63%, and the relative standard deviations (RSDs) were less than 7.19%.

  17. Considerations for estimating microbial environmental data concentrations collected from a field setting

    PubMed Central

    Silvestri, Erin E; Yund, Cynthia; Taft, Sarah; Bowling, Charlena Yoder; Chappie, Daniel; Garrahan, Kevin; Brady-Roberts, Eletha; Stone, Harry; Nichols, Tonya L

    2017-01-01

    In the event of an indoor release of an environmentally persistent microbial pathogen such as Bacillus anthracis, the potential for human exposure will be considered when remedial decisions are made. Microbial site characterization and clearance sampling data collected in the field might be used to estimate exposure. However, there are many challenges associated with estimating environmental concentrations of B. anthracis or other spore-forming organisms after such an event before being able to estimate exposure. These challenges include: (1) collecting environmental field samples that are adequate for the intended purpose, (2) conducting laboratory analyses and selecting the reporting format needed for the laboratory data, and (3) analyzing and interpreting the data using appropriate statistical techniques. This paper summarizes some key challenges faced in collecting, analyzing, and interpreting microbial field data from a contaminated site. Although the paper was written with considerations for B. anthracis contamination, it may also be applicable to other bacterial agents. It explores the implications and limitations of using field data for determining environmental concentrations both before and after decontamination. Several findings were of interest. First, to date, the only validated surface/sampling device combinations are swabs and sponge-sticks on stainless steel surfaces, thus limiting availability of quantitative analytical results which could be used for statistical analysis. Second, agreement needs to be reached with the analytical laboratory on the definition of the countable range and on reporting of data below the limit of quantitation. Finally, the distribution of the microbial field data and statistical methods needed for a particular data set could vary depending on these data that were collected, and guidance is needed on appropriate statistical software for handling microbial data. Further, research is needed to develop better methods to estimate human exposure from pathogens using environmental data collected from a field setting. PMID:26883476

  18. Composition and Morphology of Major Particle Types from Airborne Measurements during ICE-T and PRADACS Field Studies

    NASA Astrophysics Data System (ADS)

    Venero, I. M.; Mayol-Bracero, O. L.; Anderson, J. R.

    2012-12-01

    As part of the Puerto Rican African Dust and Cloud Study (PRADACS) and the Ice in Clouds Experiment - Tropical (ICE-T), we sampled giant airborne particles to study their elemental composition, morphology, and size distributions. Samples were collected in July 2011 during field measurements performed by NCAR's C-130 aircraft based on St Croix, U.S Virgin Island. The results presented here correspond to the measurements done during research flight #8 (RF8). Aerosol particles with Dp > 1 um were sampled with the Giant Nuclei Impactor and particles with Dp < 1 um were collected with the Wyoming Inlet. Collected particles were later analyzed using an automated scanning electron microscope (SEM) and manual observation by field emission SEM. We identified the chemical composition and morphology of major particle types in filter samples collected at different altitudes (e.g., 300 ft, 1000 ft, and 4500ft). Results from the flight upwind of Puerto Rico show that particles in the giant nuclei size range are dominated by sea salt. Samples collected at altitudes 300 ft and 1000 ft showed the highest number of sea salt particles and the samples collected at higher altitudes (> 4000 ft) showed the highest concentrations of clay material. HYSPLIT back trajectories for all samples showed that the low altitude samples initiated in the free troposphere in the Atlantic Ocean, which may account for the high sea salt content and that the source of the high altitude samples was closer to the Saharan - Sahel desert region and, therefore, these samples possibly had the influence of African dust. Size distribution results for quartz and unreacted sea-salt aerosols collected on the Giant Nuclei Impactor showed that sample RF08 - 12:05 UTM (300 ft) had the largest size value (mean = 2.936 μm) than all the other samples. Additional information was also obtained from the Wyoming Inlet present at the C - 130 aircraft which showed that size distribution results for all particles were smaller in size. The different mineral components of the dust have different size distributions so that a fractionation process could occur during transport. Also, the presence of supermicron sea salt at altitude is important for cloud processes.

  19. Large-scale monitoring of effects of clothianidin-dressed oilseed rape seeds on pollinating insects in northern Germany: residues of clothianidin in pollen, nectar and honey.

    PubMed

    Rolke, Daniel; Persigehl, Markus; Peters, Britta; Sterk, Guido; Blenau, Wolfgang

    2016-11-01

    This study was part of a large-scale monitoring project to assess the possible effects of Elado ® (10 g clothianidin & 2 g β-cyfluthrin/kg seed)-dressed oilseed rape seeds on different pollinators in Northern Germany. Firstly, residues of clothianidin and its active metabolites thiazolylnitroguanidine and thiazolylmethylurea were measured in nectar and pollen from Elado ® -dressed (test site, T) and undressed (reference site, R) oilseed rape collected by honey bees confined within tunnel tents. Clothianidin and its metabolites could not be detected or quantified in samples from R fields. Clothianidin concentrations in samples from T fields were 1.3 ± 0.9 μg/kg and 1.7 ± 0.9 μg/kg in nectar and pollen, respectively. Secondly, pollen and nectar for residue analyses were sampled from free flying honey bees, bumble bees and mason bees, placed at six study locations each in the R and T sites at the start of oilseed rape flowering. Honey samples were analysed from all honey bee colonies at the end of oilseed rape flowering. Neither clothianidin nor its metabolites were detectable or quantifiable in R site samples. Clothianidin concentrations in samples from the T site were below the limit of quantification (LOQ, 1.0 µg/kg) in most pollen and nectar samples collected by bees and 1.4 ± 0.5 µg/kg in honey taken from honey bee colonies. In summary, the study provides reliable semi-field and field data of clothianidin residues in nectar and pollen collected by different bee species in oilseed rape fields under common agricultural conditions.

  20. Microbial source tracking markers at three inland recreational lakes in Ohio, 2011

    USGS Publications Warehouse

    Francy, Donna S.; Stelzer, Erin A.

    2012-01-01

    During the 2011 recreational season, samples were collected for E. coli and microbial source tracking (MST) marker concentrations to begin to understand potential sources of fecal contamination at three inland recreational lakes in Ohio - Buckeye, Atwood, and Tappan Lakes. The results from 32 regular samples, 4 field blanks, and 7 field replicates collected at 5 sites are presented in this report. At the three lakes, the ruminant-associated marker was found most often (57-73 percent of samples) but at estimated quantities, followed by the dog-associated marker (30-43 percent of samples). The human-associated marker was found in 14 and 50 percent of samples from Atwood and Tappan Lakes, respectively, but was not found in any samples from the two Buckeye Lake sites. The gull-associated marker was detected in only two samples, both from Tappan Lake.

  1. Pesticide-sampling equipment, sample-collection and processing procedures, and water-quality data at Chicod Creek, North Carolina, 1992

    USGS Publications Warehouse

    Manning, T.K.; Smith, K.E.; Wood, C.D.; Williams, J.B.

    1994-01-01

    Water-quality samples were collected from Chicod Creek in the Coastal Plain Province of North Carolina during the summer of 1992 as part of the U.S. Geological Survey's National Water-Quality Assessment Program. Chicod Creek is in the Albemarle-Pamlico drainage area, one of four study units designated to test equipment and procedures for collecting and processing samples for the solid-phase extraction of selected pesticides, The equipment and procedures were used to isolate 47 pesticides, including organonitrogen, carbamate, organochlorine, organophosphate, and other compounds, targeted to be analyzed by gas chromatography/mass spectrometry. Sample-collection and processing equipment equipment cleaning and set-up procedures, methods pertaining to collecting, splitting, and solid-phase extraction of samples, and water-quality data resulting from the field test are presented in this report Most problems encountered during this intensive sampling exercise were operational difficulties relating to equipment used to process samples.

  2. Supercritical Fluid Extraction and Analysis of Tropospheric Aerosol Particles

    NASA Astrophysics Data System (ADS)

    Hansen, Kristen J.

    An integrated sampling and supercritical fluid extraction (SFE) cell has been designed for whole-sample analysis of organic compounds on tropospheric aerosol particles. The low-volume extraction cell has been interfaced with a sampling manifold for aerosol particle collection in the field. After sample collection, the entire SFE cell was coupled to a gas chromatograph; after on-line extraction, the cryogenically -focused sample was separated and the volatile compounds detected with either a mass spectrometer or a flame ionization detector. A 20-minute extraction at 450 atm and 90 ^circC with pure supercritical CO _2 is sufficient for quantitative extraction of most volatile compounds in aerosol particle samples. A comparison between SFE and thermal desorption, the traditional whole-sample technique for analyses of this type, was performed using ambient aerosol particle samples, as well as samples containing known amounts of standard analytes. The results of these studies indicate that SFE of atmospheric aerosol particles provides quantitative measurement of several classes of organic compounds. SFE provides information that is complementary to that gained by the thermal desorption analysis. The results also indicate that SFE with CO _2 can be validated as an alternative to thermal desorption for quantitative recovery of several organic compounds. In 1989, the organic constituents of atmospheric aerosol particles collected at Niwot Ridge, Colorado, along with various physical and meteorological data, were measured during a collaborative field study. Temporal changes in the composition of samples collected during summertime at the rural site were studied. Thermal desorption-GC/FID was used to quantify selected compounds in samples collected during the field study. The statistical analysis of the 1989 Niwot Ridge data set is presented in this work. Principal component analysis was performed on thirty-one variables selected from the data set in order to ascertain different source and process components, and to examine concentration changes in groups of variables with respect to time of day and meteorological conditions. Seven orthogonal groups of variables resulted from the statistical analysis; the groups serve as molecular markers for different biologic and anthropogenic emission sources. In addition, the results of the statistical analysis were used to investigate how several emission source contributions vary with respect to local atmospheric dynamics. Field studies were conducted in the urban environment in and around Boulder, CO. to characterize the dynamics, chemistry, and emission sources which affect the composition and concentration of different size-fractions of aerosol particles in the Boulder air mass. Relationships between different size fractions of particles and some gas-phase pollutants were elucidated. These field studies included an investigation of seasonal variations in the organic content and concentration of aerosol particles, and how these characteristics are related to local meteorology and to the concentration of some gas-phase pollutants. The elemental and organic composition of aerosol particles was investigated according to particle size in preliminary studies of size-differentiated samples of aerosol particles. In order to aid in future studies of urban aerosol particles, samples were collected at a forest fire near Boulder. Molecular markers specific to wood burning processes will be useful indicators of residential wood burning activities in future field studies.

  3. Development and testing of a portable wind sensitive directional air sampler

    NASA Technical Reports Server (NTRS)

    Deyo, J.; Toma, J.; King, R. B.

    1975-01-01

    A portable wind sensitive directional air sampler was developed as part of an air pollution source identification system. The system is designed to identify sources of air pollution based on the directional collection of field air samples and their analysis for TSP and trace element characteristics. Sources can be identified by analyzing the data on the basis of pattern recognition concepts. The unit, designated Air Scout, receives wind direction signals from an associated wind vane. Air samples are collected on filter slides using a standard high volume air sampler drawing air through a porting arrangement which tracks the wind direction and permits collection of discrete samples. A preset timer controls the length of time each filter is in the sampling position. At the conclusion of the sampling period a new filter is automatically moved into sampling position displacing the previous filter to a storage compartment. Thus the Air Scout may be set up at a field location, loaded with up to 12 filter slides, and left to acquire air samples automatically, according to the wind, at any timer interval desired from 1 to 30 hours.

  4. Benthic macroinvertebrate field sampling effort required to produce a sample adequate for the assessment of rivers and streams of Neuquén Province, Argentina

    EPA Science Inventory

    This multi-year pilot study evaluated a proposed field method for its effectiveness in the collection of a benthic macroinvertebrate sample adequate for use in the condition assessment of streams and rivers in the Neuquén Province, Argentina. A total of 13 sites, distribut...

  5. Evaluation of volatile organic compound (VOC) blank data and application of study reporting levels to groundwater data collected for the California GAMA Priority Basin Project, May 2004 through September 2010

    USGS Publications Warehouse

    Fram, Miranda S.; Olsen, Lisa D.; Belitz, Kenneth

    2012-01-01

    Volatile organic compounds (VOCs) were analyzed in quality-control samples collected for the California Groundwater Ambient Monitoring and Assessment (GAMA) Program Priority Basin Project. From May 2004 through September 2010, a total of 2,026 groundwater samples, 211 field blanks, and 109 source-solution blanks were collected and analyzed for concentrations of 85 VOCs. Results from analyses of these field and source-solution blanks and of 2,411 laboratory instrument blanks during the same time period were used to assess the quality of data for the 2,026 groundwater samples. Eighteen VOCs were detected in field blanks or source-solution blanks: acetone, benzene, bromodichloromethane, 2-butanone, carbon disulfide, chloroform, 1,1-dichloroethene, dichloromethane, ethylbenzene, tetrachloroethene, styrene, tetrahydrofuran, toluene, trichloroethene, trichlorofluoromethane, 1,2,4-trimethylbenzene, m- and p-xylenes, and o-xylene. The objective of the evaluation of the VOC-blank data was to determine if study reporting levels (SRLs) were needed for any of the VOCs detected in blanks to ensure the quality of the data from groundwater samples. An SRL is equivalent to a raised reporting level that is used in place of the reporting level used by the analyzing laboratory [long‑term method detection level (LT-MDL) or laboratory reporting level (LRL)] to reduce the probability of reporting false-positive detections. Evaluation of VOC-blank data was done in three stages: (1) identification of a set of representative quality‑control field blanks (QCFBs) to be used for calculation of SRLs and identification of VOCs amenable to the SRL approach, (2) evaluation of potential sources of contamination to blanks and groundwater samples by VOCs detected in field blanks, and (3) selection of appropriate SRLs from among four potential SRLs for VOCs detected in field blanks and application of those SRLs to the groundwater data. An important conclusion from this study is that to ensure the quality of the data from groundwater samples, it was necessary to apply different methods of determining SRLs from field blank data to different VOCs, rather than use the same method for all VOCs. Four potential SRL values were defined by using three approaches: two values were defined by using a binomial probability method based on one-sided, nonparametric upper confidence limits, one was defined as equal to the maximum concentration detected in the field blanks, and one was defined as equal to the maximum laboratory method detection level used during the period when samples were collected for the project. The differences in detection frequencies and concentrations among different types of blanks (laboratory instrument blanks, source-solution blanks, and field blanks collected with three different sampling equipment configurations) and groundwater samples were used to infer the sources and mechanisms of contamination for each VOC detection in field blanks. Other chemical data for the groundwater samples (oxidation-reduction state, co-occurrence of VOCs, groundwater age) and ancillary information about the well sites (land use, presence of known sources of contamination) were used to evaluate whether the patterns of detections of VOCs in groundwater samples before and after application of potential SRLs were plausible. On this basis, the appropriate SRL was selected for each VOC that was determined to require an SRL. The SRLs for ethylbenzene [0.06 microgram per liter (μg/L)], m- and p-xylenes (0.33 μg/L), o-xylene (0.12 μg/L), toluene (0.69 μg/L), and 1,2,4-trimethylbenzene (0.56 μg/L) corresponded to the highest concentrations detected in the QCFBs and were selected because they resulted in the most censoring of groundwater data. Comparisons of hydrocarbon ratios in groundwater samples and blanks and comparisons between detection frequencies of the five hydrocarbons in groundwater samples and different types of blanks suggested three dominant sources of contamination that affected groundwater samples and blanks: (1) ethylbenzene, m- and p-xylenes, o-xylene, and toluene from fuel or exhaust components sorbed onto sampling lines, (2) toluene from vials and the source blank water, and (3) 1,2,4-trimethylbenzene from materials used for collection of samples for radon-222 analysis.

  6. Instrument to collect fogwater for chemical analysis

    NASA Astrophysics Data System (ADS)

    Jacob, Daniel J.; Waldman, Jed M.; Haghi, Mehrdad; Hoffmann, Michael R.; Flagan, Richard C.

    1985-06-01

    An instrument is presented which collects large samples of ambient fogwater by impaction of droplets on a screen. The collection efficiency of the instrument is determined as a function of droplet size, and it is shown that fog droplets in the range 3-100-μm diameter are efficiently collected. No significant evaporation or condensation occurs at any stage of the collection process. Field testing indicates that samples collected are representative of the ambient fogwater. The instrument may easily be automated, and is suitable for use in routine air quality monitoring programs.

  7. Groundwater-quality and quality-control data for two monitoring wells near Pavillion, Wyoming, April and May 2012

    USGS Publications Warehouse

    Wright, Peter R.; McMahon, Peter B.; Mueller, David K.; Clark, Melanie L.

    2012-01-01

    In June 2010, the U.S. Environmental Protection Agency installed two deep monitoring wells (MW01 and MW02) near Pavillion, Wyoming, to study groundwater quality. During April and May 2012, the U.S Geological Survey, in cooperation with the Wyoming Department of Environmental Quality, collected groundwater-quality data and quality-control data from monitoring well MW01 and, following well redevelopment, quality-control data for monitoring well MW02. Two groundwater-quality samples were collected from well MW01—one sample was collected after purging about 1.5 borehole volumes, and a second sample was collected after purging 3 borehole volumes. Both samples were collected and processed using methods designed to minimize atmospheric contamination or changes to water chemistry. Groundwater-quality samples were analyzed for field water-quality properties (water temperature, pH, specific conductance, dissolved oxygen, oxidation potential); inorganic constituents including naturally occurring radioactive compounds (radon, radium-226 and radium-228); organic constituents; dissolved gasses; stable isotopes of methane, water, and dissolved inorganic carbon; and environmental tracers (carbon-14, chlorofluorocarbons, sulfur hexafluoride, tritium, helium, neon, argon, krypton, xenon, and the ratio of helium-3 to helium-4). Quality-control sample results associated with well MW01 were evaluated to determine the extent to which environmental sample analytical results were affected by bias and to evaluate the variability inherent to sample collection and laboratory analyses. Field documentation, environmental data, and quality-control data for activities that occurred at the two monitoring wells during April and May 2012 are presented.

  8. ACQUISITION OF REPRESENTATIVE GROUND WATER QUALITY SAMPLES FOR METALS

    EPA Science Inventory

    R.S. Kerr Environmental Research Laboratory (RSKERL) personnel have evaluated sampling procedures for the collection of representative, accurate, and reproducible ground water quality samples for metals for the past four years. Intensive sampling research at three different field...

  9. Preserving Geological Samples and Metadata from Polar Regions

    NASA Astrophysics Data System (ADS)

    Grunow, A.; Sjunneskog, C. M.

    2011-12-01

    The Office of Polar Programs at the National Science Foundation (NSF-OPP) has long recognized the value of preserving earth science collections due to the inherent logistical challenges and financial costs of collecting geological samples from Polar Regions. NSF-OPP established two national facilities to make Antarctic geological samples and drill cores openly and freely available for research. The Antarctic Marine Geology Research Facility (AMGRF) at Florida State University was established in 1963 and archives Antarctic marine sediment cores, dredge samples and smear slides along with ship logs. The United States Polar Rock Repository (USPRR) at Ohio State University was established in 2003 and archives polar rock samples, marine dredges, unconsolidated materials and terrestrial cores, along with associated materials such as field notes, maps, raw analytical data, paleomagnetic cores, thin sections, microfossil mounts, microslides and residues. The existence of the AMGRF and USPRR helps to minimize redundant sample collecting, lessen the environmental impact of doing polar field work, facilitates field logistics planning and complies with the data sharing requirement of the Antarctic Treaty. USPRR acquires collections through donations from institutions and scientists and then makes these samples available as no-cost loans for research, education and museum exhibits. The AMGRF acquires sediment cores from US based and international collaboration drilling projects in Antarctica. Destructive research techniques are allowed on the loaned samples and loan requests are accepted from any accredited scientific institution in the world. Currently, the USPRR has more than 22,000 cataloged rock samples available to scientists from around the world. All cataloged samples are relabeled with a USPRR number, weighed, photographed and measured for magnetic susceptibility. Many aspects of the sample metadata are included in the database, e.g. geographical location, sample description, collector, rock age, formation, section location, multimedia images as well structural data, field observations, logistics, surface features, etc. The metadata are entered into a commercial, museum based database called EMu. The AMGRF houses more than 25,000m of deep-sea cores and drill cores as well as nearly 3,000 meters of rotary cored geological material from Antarctica. Detailed information on the sediment cores including location, sediment composition are available in cruise reports posted on the AMGRF web-site. Researchers may access the sample collections through the online websites (http://www-bprc.mps.ohio-state.edu/emuwebusprr and http://www.arf.fsu.edu). Searches may be done using multiple search terms or by use of the mapping feature. The on-line databases provide an essential resource for proposal preparation, pilot studies and other sample based research that should make fieldwork more efficient.

  10. Breath-collection device for delayed breath-alcohol analysis

    DOT National Transportation Integrated Search

    1980-12-01

    The report includes the details of a study to develop, evaluate, and validate a breath collection device (BCD) for delayed breath-alcohol analysis. Primary applications of the BCD include collection of breath-alcohol samples for field surveys or for ...

  11. Chemicals of emerging concern in water and bottom sediment in Great Lakes areas of concern, 2010 to 2011-Collection methods, analyses methods, quality assurance, and data

    USGS Publications Warehouse

    Lee, Kathy E.; Langer, Susan K.; Menheer, Michael A.; Foreman, William T.; Furlong, Edward T.; Smith, Steven G.

    2012-01-01

    The U.S. Geological Survey (USGS) cooperated with the U.S. Environmental Protection Agency and the U.S. Fish and Wildlife Service on a study to identify the occurrence of chemicals of emerging concern (CECs) in water and bottom-sediment samples collected during 2010–11 at sites in seven areas of concern (AOCs) throughout the Great Lakes. Study sites include tributaries to the Great Lakes in AOCs located near Duluth, Minn.; Green Bay, Wis.; Roches­ter, N.Y.; Detroit, Mich.; Toledo, Ohio; Milwaukee, Wis.; and Ashtabula, Ohio. This report documents the collection meth­ods, analyses methods, quality-assurance data and analyses, and provides the data for this study. Water and bottom-sediment samples were analyzed at the USGS National Water Quality Laboratory in Denver, Colo., for a broad suite of CECs. During this study, 135 environmental and 23 field dupli­cate samples of surface water and wastewater effluent, 10 field blank water samples, and 11 field spike water samples were collected and analyzed. Sixty-one of the 69 wastewater indicator chemicals (laboratory method 4433) analyzed were detected at concentrations ranging from 0.002 to 11.2 micrograms per liter. Twenty-eight of the 48 pharmaceuticals (research method 8244) analyzed were detected at concentrations ranging from 0.0029 to 22.0 micro­grams per liter. Ten of the 20 steroid hormones and sterols analyzed (research method 4434) were detected at concentrations ranging from 0.16 to 10,000 nanograms per liter. During this study, 75 environmental, 13 field duplicate samples, and 9 field spike samples of bottom sediment were collected and analyzed for a wide variety of CECs. Forty-seven of the 57 wastewater indicator chemicals (laboratory method 5433) analyzed were detected at concentrations ranging from 0.921 to 25,800 nanograms per gram. Seventeen of the 20 steroid hormones and sterols (research method 6434) analyzed were detected at concentrations ranging from 0.006 to 8,921 nanograms per gram. Twelve of the 20 pharmaceuticals (research method 8244) analyzed were detected at concentrations ranging from 2.35 to 453.5 nanograms per gram. Six of the 11 antidepressants (research method 9008) analyzed were detected at concentrations ranging from 2.79 to 91.6 nanograms per gram.

  12. Soil Sampling Operating Procedure

    EPA Pesticide Factsheets

    EPA Region 4 Science and Ecosystem Support Division (SESD) document that describes general and specific procedures, methods, and considerations when collecting soil samples for field screening or laboratory analysis.

  13. Sediment Sampling Operating Procedure

    EPA Pesticide Factsheets

    EPA Region 4 Science and Ecosystem Support Division (SESD) document that describes general and specific procedures, methods, and considerations when collecting sediment samples for field screening or laboratory analysis.

  14. Study design and percent recoveries of anthropogenic organic compounds with and without the addition of ascorbic acid to preserve water samples containing free chlorine, 2004-06

    USGS Publications Warehouse

    Valder, Joshua F.; Delzer, Gregory C.; Price, Curtis V.; Sandstrom, Mark W.

    2008-01-01

    The National Water-Quality Assessment (NAWQA) Program of the U.S. Geological Survey (USGS) began implementing Source Water-Quality Assessments (SWQAs) in 2002 that focus on characterizing the quality of source water and finished water of aquifers and major rivers used by some of the larger community water systems in the United States. As used for SWQA studies, source water is the raw (ambient) water collected at the supply well prior to water treatment (for ground water) or the raw (ambient) water collected from the river near the intake (for surface water). Finished water is the water that is treated, which typically involves, in part, the addition of chlorine or other disinfection chemicals to remove pathogens, and is ready to be delivered to consumers. Finished water is collected before the water enters the distribution system. This report describes the study design and percent recoveries of anthropogenic organic compounds (AOCs) with and without the addition of ascorbic acid to preserve water samples containing free chlorine. The percent recoveries were determined by using analytical results from a laboratory study conducted in 2004 by the USGS's National Water Quality Laboratory (NWQL) and from data collected during 2004-06 for a field study currently (2008) being conducted by the USGS's NAWQA Program. The laboratory study was designed to determine if preserving samples with ascorbic acid (quenching samples) adversely affects analytical performance under controlled conditions. During the laboratory study, eight samples of reagent water were spiked for each of five analytical schedules evaluated. Percent recoveries from these samples were then compared in two ways: (1) four quenched reagent spiked samples analyzed on day 0 were compared with four quenched reagent spiked samples analyzed on day 7 or 14, and (2) the combined eight quenched reagent spiked samples analyzed on day 0, 7, or 14 were compared with eight laboratory reagent spikes (LRSs). Percent recoveries from the quenched reagent spiked samples that were analyzed at two different times (day 0 and day 7 or 14) can be used to determine the stability of the quenched samples held for an amount of time representative of the normal amount of time between sample collection and analysis. The comparison between the quenched reagent spiked samples and the LRSs can be used to determine if quenching samples adversely affects the analytical performance under controlled conditions. The field study began in 2004 and is continuing today (February 2008) to characterize the effect of quenching on field-matrix spike recoveries and to better understand the potential oxidation and transformation of 277 AOCs. Three types of samples were collected from 11 NAWQA Study Units across the Nation: (1) quenched finished-water samples (not spiked), (2) quenched finished-water spiked samples, and (3) nonquenched finished-water spiked samples. Percent recoveries of AOCs in quenched and nonquenched finished-water spiked samples collected during 2004-06 are presented. Comparisons of percent recoveries between quenched and nonquenched spiked samples can be used to show how quenching affects finished-water samples. A maximum of 6 surface-water and 7 ground-water quenched finished-water spiked samples paired with nonquenched finished-water spiked samples were analyzed. Analytical results for the field study are presented in two ways: (1) by surface-water supplies or ground-water supplies, and (2) by use (or source) group category for surface-water and ground-water supplies. Graphical representations of percent recoveries for the quenched and nonquenched finished-water spiked samples also are presented.

  15. Expanding sexually transmitted infection screening among women and men engaging in transactional sex: the feasibility of field-based self-collection.

    PubMed

    Roth, A M; Rosenberger, J G; Reece, M; Van Der Pol, B

    2013-04-01

    Routine screening is a key component of sexually transmitted infection (STI) prevention and control; however, traditional programmes often fail to effectively reach men and women in hidden communities. To reduce prevalence, we must understand the programmatic features that would encourage utilization of services among asymptomatic individuals. Using incentivized snowball sampling, 44 women and men recently engaging in transactional sex were recruited (24 women, 20 men); median age 37 years. Respondents were offered the opportunity to collect genital, oropharyngeal and rectal samples for STI testing and completed a face-to-face interview about their experience with self-obtained sampling. Interviews were analysed using qualitative methods. Participants were unaware of potential risk for STI, but found self-sampling in non-clinical settings to be acceptable and preferable to clinic-based testing. All participants collected genital specimens; 96% and 4% collected oropharyngeal and rectal specimens, respectively. The burden of disease in this population was high: 38% tested positive for at least one STI. We detected multiple concomitant infections. Incorporating field collection of self-obtained samples into STI control programmes may increase utilization among high-risk populations unlikely to access clinic-based services. High infection rates indicate that individuals engaging in transactional sex would benefit from, and be responsive to, community-based self-sampling for STI screening.

  16. Corrective Action Investigation Plan for Corrective Action Unit 428: Area 3 Septic Waste Systems 1 and 5, Tonopah Test Range, Nevada, REVISION 0, march 1999

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DOE /NV

    1999-03-26

    The Corrective Action Investigation Plan for Corrective Action Unit 428, Area 3 Septic Waste Systems 1 and 5, has been developed in accordance with the Federal Facility Agreement and Consent Order that was agreed to by the U. S. Department of Energy, Nevada Operations Office; the State of Nevada Division of Environmental Protection; and the U. S. Department of Defense. Corrective Action Unit 428 consists of Corrective Action Sites 03- 05- 002- SW01 and 03- 05- 002- SW05, respectively known as Area 3 Septic Waste System 1 and Septic Waste System 5. This Corrective Action Investigation Plan is used inmore » combination with the Work Plan for Leachfield Corrective Action Units: Nevada Test Site and Tonopah Test Range, Nevada , Rev. 1 (DOE/ NV, 1998c). The Leachfield Work Plan was developed to streamline investigations at leachfield Corrective Action Units by incorporating management, technical, quality assurance, health and safety, public involvement, field sampling, and waste management information common to a set of Corrective Action Units with similar site histories and characteristics into a single document that can be referenced. This Corrective Action Investigation Plan provides investigative details specific to Corrective Action Unit 428. A system of leachfields and associated collection systems was used for wastewater disposal at Area 3 of the Tonopah Test Range until a consolidated sewer system was installed in 1990 to replace the discrete septic waste systems. Operations within various buildings at Area 3 generated sanitary and industrial wastewaters potentially contaminated with contaminants of potential concern and disposed of in septic tanks and leachfields. Corrective Action Unit 428 is composed of two leachfield systems in the northern portion of Area 3. Based on site history collected to support the Data Quality Objectives process, contaminants of potential concern for the site include oil/ diesel range total petroleum hydrocarbons, and Resource Conservation and Recovery Act characteristic volatile organic compounds, semivolatile organic compounds, and metals. A limited number of samples will be analyzed for gamma- emitting radionuclides and isotopic uranium from four of the septic tanks and if radiological field screening levels are exceeded. Additional samples will be analyzed for geotechnical and hydrological properties and a bioassessment may be performed. The technical approach for investigating this Corrective Action Unit consists of the following activities: (1) Perform video surveys of the discharge and outfall lines. (2) Collect samples of material in the septic tanks. (3) Conduct exploratory trenching to locate and inspect subsurface components. (4) Collect subsurface soil samples in areas of the collection system including the septic tanks and outfall end of distribution boxes. (5) Collect subsurface soil samples underlying the leachfield distribution pipes via trenching. (6) Collect surface and near- surface samples near potential locations of the Acid Sewer Outfall if Septic Waste System 5 Leachfield cannot be located. (7) Field screen samples for volatile organic compounds, total petroleum hydrocarbons, and radiological activity. (8) Drill boreholes and collect subsurface soil samples if required. (9) Analyze samples for total volatile organic compounds, total semivolatile organic compounds, total Resource Conservation and Recovery Act metals, and total petroleum hydrocarbons (oil/ diesel range organics). Limited number of samples will be analyzed for gamma- emitting radionuclides and isotopic uranium from particular septic tanks and if radiological field screening levels are exceeded. (10) Collect samples from native soils beneath the distribution system and analyze for geotechnical/ hydrologic parameters. (11) Collect and analyze bioassessment samples at the discretion of the Site Supervisor if total petroleum hydrocarbons exceed field- screening levels.« less

  17. Studies on geotechnical properties of subsoil in south east coastal region of India

    NASA Astrophysics Data System (ADS)

    Dutta, Susom; Barik, D. K.

    2017-11-01

    Soil testing and analysis has become essential before commencement of any activity or process on soil i.e. residential construction, road construction etc. It is the most important work particularly in coastal area as these areas are more vulnerable to the natural disastrous like tsunami and cyclone. In India, there is lack of facility to collect and analyse the soil from the field. Hence, to study the various characteristics of the coastal region sub soil, Old Mahabalipuram area, which is the South East region of India has been chosen in this study. The aim of this study is to collect and analyse the soil sample from various localities of the Old Mahabalipuram area. The analysed soil data will be helpful for the people who are working in the field of Geotechnical in coastal region of India to make decision. The soil sample collected from different boreholes have undergone various field and laboratory tests like Pressuremeter Test, Field Permeability Test, Electrical Resistivity Test, Standard Penetration Test, Shear Test, Atterberg Limits etc. are performed including rock tests to know the geotechnical properties of the soil samples for each and every stratum

  18. Sampling the Soils around a Residence Containing Lead-Based Paints: An X-Ray Fluorescence Experiment

    ERIC Educational Resources Information Center

    Bachofer, Steven J.

    2008-01-01

    Sampling experiments utilizing field portable instruments are instructional since students collect data following regulatory protocols, evaluate it, and begin to recognize their civic responsibilities upon collecting useful data. A lead-in-soil experiment educated students on a prevalent exposure pathway. The experimental site was a pre-1950…

  19. Effect of sample initial magnetic field on the metal magnetic memory NDT result

    NASA Astrophysics Data System (ADS)

    Moonesan, Mahdi; Kashefi, Mehrdad

    2018-08-01

    One of the major concerns regarding the use of Metal Magnetic Memory (MMM) technique is the complexity of residual magnetization effect on output signals. The present study investigates the influence of residual magnetic field on stress induced magnetization. To this end, various initial magnetic fields were induced on a low carbon steel sample, and for each level of residual magnetic field, the sample was subjected to a set of 4-point bending tests and, their corresponding MMM signals were collected from the surface of the bended sample using a tailored metal magnetic memory scanning device. Results showed a strong correlation between sample residual magnetic field and its corresponding level of stress induced magnetic field. It was observed that the sample magnetic field increases with applying the bending stress as long as the initial residual magnet field is low (i.e. <117 mG), but starts decreasing with higher levels of initial residual magnetic fields. Besides, effect of bending stress on the MMM output of a notched sample was investigated. The result, again, showed that MMM signals exhibit a drop at stress concentration zone when sample has high level of initial residual magnetic field.

  20. Determination of the anionic surfactant di(ethylhexyl) sodium sulfosuccinate in water samples collected from Gulf of Mexico coastal waters before and after landfall of oil from the Deepwater Horizon oil spill, May to October, 2010

    USGS Publications Warehouse

    Gray, James L.; Kanagy, Leslie K.; Furlong, Edward T.; McCoy, Jeff W.; Kanagy, Chris J.

    2011-01-01

    On April 22, 2010, the explosion on and subsequent sinking of the Deepwater Horizon oil drilling platform resulted in the release of crude oil into the Gulf of Mexico. At least 4.4 million barrels had been released into the Gulf of Mexico through July 15, 2010, 10 to 29 percent of which was chemically dispersed, primarily using two dispersant formulations. Initially, the dispersant Corexit 9527 was used, and when existing stocks of that formulation were exhausted, Corexit 9500 was used. Over 1.8 million gallons of the two dispersants were applied in the first 3 months after the spill. This report presents the development of an analytical method to analyze one of the primary surfactant components of both Corexit formulations, di(ethylhexyl) sodium sulfosuccinate (DOSS), the preliminary results, and the associated quality assurance/quality control (QA/QC) from samples collected from various points on the Gulf Coast between Texas and Florida. Seventy water samples and 8 field QC samples were collected before the predicted landfall of oil (pre-landfall) on the Gulf Coast, and 51 water samples and 10 field QC samples after the oil made landfall (post-landfall). Samples were collected in Teflon(Registered) bottles and stored at -20(degrees)C until analysis. Extraction of whole-water samples used sorption onto a polytetrafluoroethylene (PTFE) filter to isolate DOSS, with subsequent 50 percent methanol/water elution of the combined dissolved and particulate DOSS fractions. High-performance liquid chromatography/tandem mass spectrometry (LC/MS/MS) was used to identify and quantify DOSS by the isotope dilution method, using a custom-synthesized 13C4-DOSS labeled standard. Because of the ubiquitous presence of DOSS in laboratory reagent water, a chromatographic column was installed in the LC/MS/MS between the system pumps and the sample injector that separated this ambient background DOSS contamination from the sample DOSS, minimizing one source of blank contamination. Laboratory and field QA/QC for pre-landfall samples included laboratory reagent spike and blank samples, a total of 34 replicate analyses for the 78 environmental and field blank samples, and 11 randomly chosen laboratory matrix spike samples. Laboratory and field QA/QC for post-landfall samples included laboratory reagent spike and blank samples, a laboratory 'in-bottle' duplicate for each sample, and analysis of 24 randomly chosen laboratory matrix spike samples. Average DOSS recovery of 89(+/-)9.5 percent in all native (non-13C4-DOSS ) spikes was observed, with a mean relative percent difference between sample duplicates of 36 percent. The reporting limit for this analysis was 0.25 micrograms per liter due to blank limitations; DOSS was not detected in any samples collected in October (after oil landfall at certain study sites) above that concentration. It was detected prior to oil landfall above 0.25 micrograms per liter in 3 samples, but none exceeded the Environmental Protection Agency aquatic life criteria of 40 micrograms per liter.

  1. A Simple Approach for Obtaining High Resolution, High Sensitivity ¹H NMR Metabolite Spectra of Biofluids with Limited Mass Supply

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu, Jian Zhi; Rommereim, Donald N.; Wind, Robert A.

    2006-11-01

    A simple approach is reported that yields high resolution, high sensitivity ¹H NMR spectra of biofluids with limited mass supply. This is achieved by spinning a capillary sample tube containing a biofluid at the magic angle at a frequency of about 80Hz. A 2D pulse sequence called ¹H PASS is then used to produce a high-resolution ¹H NMR spectrum that is free from magnetic susceptibility induced line broadening. With this new approach a high resolution ¹H NMR spectrum of biofluids with a volume less than 1.0 µl can be easily achieved at a magnetic field strength as low as 7.05T.more » Furthermore, the methodology facilitates easy sample handling, i.e., the samples can be directly collected into inexpensive and disposable capillary tubes at the site of collection and subsequently used for NMR measurements. In addition, slow magic angle spinning improves magnetic field shimming and is especially suitable for high throughput investigations. In this paper first results are shown obtained in a magnetic field of 7.05T on urine samples collected from mice using a modified commercial NMR probe.« less

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Puls, R.W.; Powell, R.M.

    R.S. Kerr Environmental Research Laboratory (RSKERL) personnel have evaluated sampling procedures for the collection of representative, accurate, and reproducible ground water quality samples for metals for the past four years. Intensive sampling research at three different field sites has shown that the method by which samples are collected has a greater impact on sample quality, accuracy, and reproducibility than whether the samples are filtered or not. In particular, sample collection practices that induce artifically high levels of turbidity have been shown to have the greatest negative impacts on sample quality. Results indicated the ineffectiveness of bailer for collection of representativemore » metal samples. Inconsistent operator usage together with excessive purging generally resulted in excessive turbidity and large differences in filtered and unfiltered metal samples. The use of low flow rate purging and sampling consistently produced filtered and unfiltered samples that showed no significant differences in concentrations. Turbidity levels were generally less than 5 NTUs, even in fine-textured glacial till. The authors recommend the use of low flow rates, during both purging and sampling.« less

  3. Genetic variability of spined soldier bugs (Hemiptera: Pentatomidae) sampled from distinct field sites and laboratory colonies in the United States

    USDA-ARS?s Scientific Manuscript database

    The spined soldier bug, Podisus maculiventris (Say), is an important biological control agent for agricultural and forest pests that preys on eggs and larvae of lepidopteran and coleopteran species. Genetic variability among field collected samples from Michigan, Mississippi, Missouri, and Florida, ...

  4. Lichen communities indicator results from Idaho: baseline sampling

    Treesearch

    Peter Neitlich; Paul Rogers; Roger Rosentreter

    2003-01-01

    Epiphytic lichen communities are included in the national Forest Health Monitoring (FHM) program because they help us assess resource contamination, biodiversity, and sustainability in the context of forest health. In 1996, field crews collected lichen samples on 141 field plots systematically located across all forest ownership groups in Idaho. Results presented here...

  5. Opportune Landing Site Program: Opportune Landing Site Southeastern Indiana Field Data Collection and Assessment

    DTIC Science & Technology

    2008-11-01

    consisted of eight fundamental tasks. Boeing (1) pro - vided software allowing the selection of OLS locations using satellite im- agery, (2) provided a...IOP1 to determine the stratigraphy of the soil horizons, collect samples to determine the soil texture, and collect pro - file measurements of the soil...However, using the wet density value from the gauge with an oven-dry moisture con - tent from a sample collected at the same location where the density

  6. Airborne detection and quantification of swine influenza a virus in air samples collected inside, outside and downwind from swine barns.

    PubMed

    Corzo, Cesar A; Culhane, Marie; Dee, Scott; Morrison, Robert B; Torremorell, Montserrat

    2013-01-01

    Airborne transmission of influenza A virus (IAV) in swine is speculated to be an important route of virus dissemination, but data are scarce. This study attempted to detect and quantify airborne IAV by virus isolation and RRT-PCR in air samples collected under field conditions. This was accomplished by collecting air samples from four acutely infected pig farms and locating air samplers inside the barns, at the external exhaust fans and downwind from the farms at distances up to 2.1 km. IAV was detected in air samples collected in 3 out of 4 farms included in the study. Isolation of IAV was possible from air samples collected inside the barn at two of the farms and in one farm from the exhausted air. Between 13% and 100% of samples collected inside the barns tested RRT-PCR positive with an average viral load of 3.20E+05 IAV RNA copies/m³ of air. Percentage of exhaust positive air samples also ranged between 13% and 100% with an average viral load of 1.79E+04 RNA copies/m³ of air. Influenza virus RNA was detected in air samples collected between 1.5 and 2.1 Km away from the farms with viral levels significantly lower at 4.65E+03 RNA copies/m³. H1N1, H1N2 and H3N2 subtypes were detected in the air samples and the hemagglutinin gene sequences identified in the swine samples matched those in aerosols providing evidence that the viruses detected in the aerosols originated from the pigs in the farms under study. Overall our results indicate that pigs can be a source of IAV infectious aerosols and that these aerosols can be exhausted from pig barns and be transported downwind. The results from this study provide evidence of the risk of aerosol transmission in pigs under field conditions.

  7. Airborne Detection and Quantification of Swine Influenza A Virus in Air Samples Collected Inside, Outside and Downwind from Swine Barns

    PubMed Central

    Corzo, Cesar A.; Culhane, Marie; Dee, Scott; Morrison, Robert B.; Torremorell, Montserrat

    2013-01-01

    Airborne transmission of influenza A virus (IAV) in swine is speculated to be an important route of virus dissemination, but data are scarce. This study attempted to detect and quantify airborne IAV by virus isolation and RRT-PCR in air samples collected under field conditions. This was accomplished by collecting air samples from four acutely infected pig farms and locating air samplers inside the barns, at the external exhaust fans and downwind from the farms at distances up to 2.1 km. IAV was detected in air samples collected in 3 out of 4 farms included in the study. Isolation of IAV was possible from air samples collected inside the barn at two of the farms and in one farm from the exhausted air. Between 13% and 100% of samples collected inside the barns tested RRT-PCR positive with an average viral load of 3.20E+05 IAV RNA copies/m3 of air. Percentage of exhaust positive air samples also ranged between 13% and 100% with an average viral load of 1.79E+04 RNA copies/m3 of air. Influenza virus RNA was detected in air samples collected between 1.5 and 2.1 Km away from the farms with viral levels significantly lower at 4.65E+03 RNA copies/m3. H1N1, H1N2 and H3N2 subtypes were detected in the air samples and the hemagglutinin gene sequences identified in the swine samples matched those in aerosols providing evidence that the viruses detected in the aerosols originated from the pigs in the farms under study. Overall our results indicate that pigs can be a source of IAV infectious aerosols and that these aerosols can be exhausted from pig barns and be transported downwind. The results from this study provide evidence of the risk of aerosol transmission in pigs under field conditions. PMID:23951164

  8. Rapid plant diversity assessment using a pixel nested plot design: A case study in Beaver Meadows, Rocky Mountain National Park, Colorado, USA

    USGS Publications Warehouse

    Kalkhan, M.A.; Stafford, E.J.; Stohlgren, T.J.

    2007-01-01

    Geospatial statistical modelling and thematic maps have recently emerged as effective tools for the management of natural areas at the landscape scale. Traditional methods for the collection of field data pertaining to questions of landscape were developed without consideration for the parameters of these applications. We introduce an alternative field sampling design based on smaller unbiased random plot and subplot locations called the pixel nested plot (PNP). We demonstrate the applicability of the PNP design of 15 m x 15 m to assess patterns of plant diversity and species richness across the landscape at Rocky Mountain National Park (RMNP), Colorado, USA in a time (cost)-efficient manner for field data collection. Our results produced comparable results to a previous study in the Beaver Meadow study (BMS) area within RMNP, where there was a demonstrated focus of plant diversity. Our study used the smaller PNP sampling design for field data collection which could be linked to geospatial information data and could be used for landscape-scale analyses and assessment applications. In 2003, we established 61 PNP in the eastern region of RMNP. We present a comparison between this approach using a sub-sample of 19 PNP from this data set and 20 of Modified Whittaker nested plots (MWNP) of 20 m x 50 m that were collected in the BMS area. The PNP captured 266 unique plant species while the MWNP captured 275 unique species. Based on a comparison of PNP and MWNP in the Beaver Meadows area, RMNP, the PNP required less time and area sampled to achieve a similar number of species sampled. Using the PNP approach for data collection can facilitate the ecological monitoring of these vulnerable areas at the landscape scale in a time- and therefore cost-effective manner. ?? 2007 The Authors.

  9. Collection methods and quality assessment for Esche-richia coli, water quality, and microbial source tracking data within Tumacácori National Historical Park and the upper Santa Cruz River, Arizona, 2015-16

    USGS Publications Warehouse

    Paretti, Nicholas; Coes, Alissa L.; Kephart, Christopher M.; Mayo, Justine

    2018-03-05

    Tumacácori National Historical Park protects the culturally important Mission, San José de Tumacácori, while also managing a portion of the ecologically diverse riparian corridor of the Santa Cruz River. This report describes the methods and quality assurance procedures used in the collection of water samples for the analysis of Escherichia coli (E. coli), microbial source tracking markers, suspended sediment, water-quality parameters, turbidity, and the data collection for discharge and stage; the process for data review and approval is also described. Finally, this report provides a quantitative assessment of the quality of the E. coli, microbial source tracking, and suspended sediment data.The data-quality assessment revealed that bias attributed to field and laboratory contamination was minimal, with E. coli detections in only 3 out of 33 field blank samples analyzed. Concentrations in the field blanks were several orders of magnitude lower than environmental concentrations. The microbial source tracking (MST) field blank was below the detection limit for all MST markers analyzed. Laboratory blanks for E. coli at the USGS Arizona Water Science Center and laboratory blanks for MST markers at the USGS Ohio Water Microbiology Laboratory were all below the detection limit. Irreplicate data for E. coli and suspended sediment indicated that bias was not introduced to the data by combining samples collected using discrete sampling methods with samples collected using automatic sampling methods.The split and sequential E. coli replicate data showed consistent analytical variability and a single equation was developed to explain the variability of E. coli concentrations. An additional analysis of analytical variability for E. coli indicated analytical variability around 18 percent relative standard deviation and no trend was observed in the concentration during the processing and analysis of multiple split-replicates. Two replicate samples were collected for MST and individual markers were compared for a base flow and flood sample. For the markers found in common between the two types of samples, the relative standard deviation for the base flow sample was more than 3 times greater than the markers in the flood sample. Sequential suspended sediment replicates had a relative standard deviation of about 1.3 percent, indicating that environmental and analytical variability was minimal.A holding time review and laboratory study analysis supported the extended holding times required for this investigation. Most concentrations for flood and base-flow samples were within the theoretical variability specified in the most probable number approach suggesting that extended hold times did not overly influence the final concentrations reported.

  10. MAP3S precipitation chemistry network. Third periodic summary report, July 1978-December 1979

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1980-05-01

    The MAP3S Precipitation Chemistry Network consists of eight collection sites in the northeastern United States. Precipitation event samples are collected by cooperating site operators, using specially developed sampling equipment. In this, the third periodic summary report, are listed field and concentration data for the period July 1, 1978 to December 31, 1979. Over three years' samples have been collected at most of the sites, which went into operation between September 1976 and October 1978. Samples are chemically analyzed at a central laboratory for 13 pollutant species. Weekly samples in addition to event samples were collected over a 1 1/2 yearmore » period at three sites. Analysis of one year's results indicates that there is little difference between the concentrations collected by the two methods in terms of seasonal precipitation-weighted means for all species except dissolved SO/sub 2/. Event samples tend to average about 25% higher in SO/sub 2/ than weekly samples.« less

  11. Aqueous geochemical data from the analysis of stream-water samples collected in June and July 2006-Taylor Mountains 1:250,00-scale quadrangle, Alaska

    USGS Publications Warehouse

    Wang, Bronwen; Mueller, Seth; Stetson, Sarah; Bailey, Elizabeth; Lee, Greg

    2011-01-01

    We report on the chemical analysis of water samples collected from the Taylor Mountains 1:250,000-scale quadrangle, Alaska. Parameters for which data are reported include pH, conductivity, water temperature, major cation and anion concentrations, trace-element concentrations, and dissolved organic-carbon concentrations. Samples were collected as part of a multiyear U.S. Geological Survey project entitled ?Geologic and Mineral Deposit Data for Alaskan Economic Development.? Data presented here are from samples collected in June and July 2006. The data are being released at this time with minimal interpretation. This is the third release of aqueous geochemical data from this project; aqueous geochemical data from samples collected in 2004 and 2005 were published previously. The data in this report augment but do not duplicate or supersede the previous data release. Site selection was based on a regional sampling strategy that focused on first- and second-order drainages. Water sample site selection was based on landscape parameters that included physiography, wetland extent, lithological changes, and a cursory field review of mineralogy from pan concentrates. Stream water in the Taylor Mountains quadrangle is dominated by bicarbonate (HCO3-), although in a few samples more than 50 percent of the anionic charge can be attributed to sulfate (SO42-). The major-cation chemistry ranges from Ca2+/Mg2+ dominated to a mix of Ca2+/Mg2+/Na++K+. Generally, good agreement was found between the major cations and anions in the duplicate samples. Many trace elements in these samples were at or near the analytical method detection limit, but good agreement was found between duplicate samples for elements with detectable concentrations. All field blank major-ion and trace-element concentrations were below detection.

  12. Dried Blood Spot Collection of Health Biomarkers to Maximize Participation in Population Studies

    PubMed Central

    Ostler, Michael W.; Porter, James H.; Buxton, Orfeu M.

    2014-01-01

    Biomarkers are directly-measured biological indicators of disease, health, exposures, or other biological information. In population and social sciences, biomarkers need to be easy to obtain, transport, and analyze. Dried Blood Spots meet this need, and can be collected in the field with high response rates. These elements are particularly important in longitudinal study designs including interventions where attrition is critical to avoid, and high response rates improve the interpretation of results. Dried Blood Spot sample collection is simple, quick, relatively painless, less invasive then venipuncture, and requires minimal field storage requirements (i.e. samples do not need to be immediately frozen and can be stored for a long period of time in a stable freezer environment before assay). The samples can be analyzed for a variety of different analytes, including cholesterol, C-reactive protein, glycosylated hemoglobin, numerous cytokines, and other analytes, as well as provide genetic material. DBS collection is depicted as employed in several recent studies. PMID:24513728

  13. Soil Gas Sampling Operating Procedure

    EPA Pesticide Factsheets

    EPA Region 4 Science and Ecosystem Support Division (SESD) document that describes general and specific procedures, methods, and considerations when collecting soil gas samples for field screening or laboratory analysis.

  14. Establishment and operation of the National Accident Sampling System (NASS) team within the cities of Ft. Lauderdale/Hollywood, Florida

    NASA Astrophysics Data System (ADS)

    Beddow, B.; Roberts, C.; Rankin, J.; Bloch, A.; Peizer, J.

    1981-01-01

    The National Accident Sampling System (NASS) is described. The study area discussed is one of the original ten sites selected for NASS implementation. In addition to collecting data from the field, the original ten sites address questions of feasibility of the plan, projected results of the data collection effort, and specific operational topics, e.g., team size, sampling requirements, training approaches, quality control procedures, and field techniques. Activities and results of the first three years of the project, for both major tasks (establishment and operation) are addressed. Topics include: study area documentation; team description, function and activities; problems and solutions; and recommendations.

  15. Differences in results of analyses of concurrent and split stream-water samples collected and analyzed by the US Geological Survey and the Illinois Environmental Protection Agency, 1985-91

    USGS Publications Warehouse

    Melching, C.S.; Coupe, R.H.

    1995-01-01

    During water years 1985-91, the U.S. Geological Survey (USGS) and the Illinois Environmental Protection Agency (IEPA) cooperated in the collection and analysis of concurrent and split stream-water samples from selected sites in Illinois. Concurrent samples were collected independently by field personnel from each agency at the same time and sent to the IEPA laboratory, whereas the split samples were collected by USGS field personnel and divided into aliquots that were sent to each agency's laboratory for analysis. The water-quality data from these programs were examined by means of the Wilcoxon signed ranks test to identify statistically significant differences between results of the USGS and IEPA analyses. The data sets for constituents and properties identified by the Wilcoxon test as having significant differences were further examined by use of the paired t-test, mean relative percentage difference, and scattergrams to determine if the differences were important. Of the 63 constituents and properties in the concurrent-sample analysis, differences in only 2 (pH and ammonia) were statistically significant and large enough to concern water-quality engineers and planners. Of the 27 constituents and properties in the split-sample analysis, differences in 9 (turbidity, dissolved potassium, ammonia, total phosphorus, dissolved aluminum, dissolved barium, dissolved iron, dissolved manganese, and dissolved nickel) were statistically significant and large enough to con- cern water-quality engineers and planners. The differences in concentration between pairs of the concurrent samples were compared to the precision of the laboratory or field method used. The differences in concentration between pairs of the concurrent samples were compared to the precision of the laboratory or field method used. The differences in concentration between paris of split samples were compared to the precision of the laboratory method used and the interlaboratory precision of measuring a given concentration or property. Consideration of method precision indicated that differences between concurrent samples were insignificant for all concentrations and properties except pH, and that differences between split samples were significant for all concentrations and properties. Consideration of interlaboratory precision indicated that the differences between the split samples were not unusually large. The results for the split samples illustrate the difficulty in obtaining comparable and accurate water-quality data.

  16. Variability of pesticide residues in cauliflower units collected from a field trial and market places in Greece.

    PubMed

    Prodhan, M D H; Papadakis, Emmanouil-N; Papadopoulou-Mourkidou, Euphemia

    2016-09-01

    To estimate the variability of pesticide residue levels present in cauliflower units, a total of 142 samples were collected from a field trial of a cooperative farmer, and 120 samples were collected from different market places in Thessaloniki, Greece. The collected samples were extracted using the quick, easy, cheap, effective, rugged, and safe (QuEChERS) extraction technique, and the residues were determined by liquid chromatography-tandem mass spectrometry. The developed method was validated by evaluating the accuracy, precision, linearity, limit of detection (LOD), and limit of quantification (LOQ). The average recoveries for all the analytes, derived from the data of control samples fortified at 0.01, 0.05, 0.1, and 0.2 mg/kg, ranged from 74 to 110% with a relative standard deviation of ≤8%. The correlation coefficient (R(2)) was ≥0.997 for all the analytes using matrix-matched calibration standards. The LOD values ranged from 0.001 to 0.003 mg/kg, and the LOQ was determined at 0.01 mg/kg for all the sought analytes. The matrix effect was found to be at a considerable level, especially for cypermethrin and deltamethrin, amounting to +90% and +145%, respectively. For the field samples, the unit-to-unit variability factors (VFs) calculated for cypermethrin and deltamethrin were 2.38 and 2.32, respectively, while the average VF for the market basket samples was 5.11. In the market basket samples, residues of cypermethrin, deltamethrin, chlorpyrifos, and indoxacarb were found at levels ≥LOQ and their respective VFs were 7.12, 5.67, 5.28, and 2.40.

  17. Exposure of native bees foraging in an agricultural landscape to current-use pesticides

    USGS Publications Warehouse

    Hladik, Michelle; Vandever, Mark W.; Smalling, Kelly L.

    2016-01-01

    The awareness of insects as pollinators and indicators of environmental quality has grown in recent years, partially in response to declines in honey bee (Apis mellifera) populations. While most pesticide research has focused on honey bees, there has been less work on native bee populations. To determine the exposure of native bees to pesticides, bees were collected from an existing research area in northeastern Colorado from two land cover types: grasslands (2013-2014) and wheat fields (2014). Traps were deployed bi-monthly during the summer at each land cover type and all bees, regardless of species, were composited as whole samples and analyzed for 136 current-use pesticides and degradates. This reconnaissance approach provides a sampling of all species and represents overall pesticide exposure (internal and external). Nineteen pesticides and degradates were detected in 54 composite samples collected. Compounds detected in >10% of the samples included the insecticides thiamethoxam (46%), bifenthrin (28%), clothianidin (24%), chlorpyrifos (17%), and imidacloprid (13%), the fungicides azoxystrobin (17%), and pyraclostrobin (11%), and the herbicide atrazine (19%). Concentrations ranged from 1.1 to 312 ng/g for individual pesticides. Pesticides were detected in samples collected from both grasslands and wheat fields; the location of the sample and the surrounding land cover at the 1000 m buffer influenced the pesticides detected but because of a small number of temporally comparable samples, correlations between pesticide concentration and land cover were not significant. The results show native bees collected in both grasslands and wheat fields are exposed to multiple pesticides, these results can direct future research on routes/timing of pesticide exposure and the design of future conservation efforts for pollinators.

  18. Reconnaissance of Organic Wastewater Compounds at a Concentrated Swine Feeding Operation in the North Carolina Coastal Plain, 2008

    USGS Publications Warehouse

    Harden, Stephen L.

    2009-01-01

    Water-quality and hydrologic data were collected during 2008 to examine the occurrence of organic wastewater compounds at a concentrated swine feeding operation located in the North Carolina Coastal Plain. Continuous groundwater level and stream-stage data were collected at one monitoring well and one stream site, respectively, throughout 2008. One round of environmental and quality-control samples was collected in September 2008 following a period of below-normal precipitation and when swine waste was not being applied to the spray fields. Samples were collected at one lagoon site, seven shallow groundwater sites, and one surface-water site for analysis of 111 organic wastewater compounds, including household, industrial, and agricultural-use compounds, sterols, pharmaceutical compounds, hormones, and antibiotics. Analytical data for environmental samples collected during the study provide preliminary information on the occurrence of organic wastewater compounds in the lagoon-waste source material, groundwater beneath fields that receive spray applications of the lagoon wastes, and surface water in the tributary adjacent to the site. Overall, 28 organic wastewater compounds were detected in the collected samples, including 11 household, industrial, and agricultural-use compounds; 3 sterols; 2 pharmaceutical compounds; 5 hormones; and 7 antibiotics. The lagoon sample had the greatest number (20) and highest concentrations of compounds compared to groundwater and surface-water samples. The antibiotic lincomycin had the maximum detected concentration (393 micrograms per liter) in the lagoon sample. Of the 11 compounds identified in the groundwater and surface-water samples, all with reported concentrations less than 1 microgram per liter, only lincomycin identified in groundwater at 1 well and 3-methyl-1H-indole and indole identified in surface water at 1 site also were identified in the lagoon waste material.

  19. Methods for the field evaluation of quantitative G6PD diagnostics: a review.

    PubMed

    Ley, Benedikt; Bancone, Germana; von Seidlein, Lorenz; Thriemer, Kamala; Richards, Jack S; Domingo, Gonzalo J; Price, Ric N

    2017-09-11

    Individuals with glucose-6-phosphate dehydrogenase (G6PD) deficiency are at risk of severe haemolysis following the administration of 8-aminoquinoline compounds. Primaquine is the only widely available 8-aminoquinoline for the radical cure of Plasmodium vivax. Tafenoquine is under development with the potential to simplify treatment regimens, but point-of-care (PoC) tests will be needed to provide quantitative measurement of G6PD activity prior to its administration. There is currently a lack of appropriate G6PD PoC tests, but a number of new tests are in development and are likely to enter the market in the coming years. As these are implemented, they will need to be validated in field studies. This article outlines the technical details for the field evaluation of novel quantitative G6PD diagnostics such as sample handling, reference testing and statistical analysis. Field evaluation is based on the comparison of paired samples, including one sample tested by the new assay at point of care and one sample tested by the gold-standard reference method, UV spectrophotometry in an established laboratory. Samples can be collected as capillary or venous blood; the existing literature suggests that potential differences in capillary or venous blood are unlikely to affect results substantially. The collection and storage of samples is critical to ensure preservation of enzyme activity, it is recommended that samples are stored at 4 °C and testing occurs within 4 days of collection. Test results can be visually presented as scatter plot, Bland-Altman plot, and a histogram of the G6PD activity distribution of the study population. Calculating the adjusted male median allows categorizing results according to G6PD activity to calculate standard performance indicators and to perform receiver operating characteristic (ROC) analysis.

  20. Validation of DESS as a DNA Preservation Method for the Detection of Strongyloides spp. in Canine Feces.

    PubMed

    Beknazarova, Meruyert; Millsteed, Shelby; Robertson, Gemma; Whiley, Harriet; Ross, Kirstin

    2017-06-09

    Strongyloides stercoralis is a gastrointestinal parasitic nematode with a life cycle that includes free-living and parasitic forms. For both clinical (diagnostic) and environmental evaluation, it is important that we can detect Strongyloides spp. in both human and non-human fecal samples. Real-time PCR is the most feasible method for detecting the parasite in both clinical and environmental samples that have been preserved. However, one of the biggest challenges with PCR detection is DNA degradation during the postage time from rural and remote areas to the laboratory. This study included a laboratory assessment and field validation of DESS (dimethyl sulfoxide, disodium EDTA, and saturated NaCl) preservation of Strongyloides spp. DNA in fecal samples. The laboratory study investigated the capacity of 1:1 and 1:3 sample to DESS ratios to preserve Strongyloides ratti in spike canine feces. It was found that both ratios of DESS significantly prevented DNA degradation compared to the untreated sample. This method was then validated by applying it to the field-collected canine feces and detecting Strongyloides DNA using PCR. A total of 37 canine feces samples were collected and preserved in the 1:3 ratio (sample: DESS) and of these, 17 were positive for Strongyloides spp. The study shows that both 1:1 and 1:3 sample to DESS ratios were able to preserve the Strongyloides spp. DNA in canine feces samples stored at room temperature for up to 56 days. This DESS preservation method presents the most applicable and feasible method for the Strongyloides DNA preservation in field-collected feces.

  1. Aqueous Geochemical Data From the Analysis of Stream-Water Samples Collected in June and July 2005--Taylor Mountains 1:250,000 Scale Quadrangle, Alaska

    USGS Publications Warehouse

    Wang, Bronwen; Mueller, Seth; Stetson, Sarah; Bailey, Elizabeth; Lee, Greg

    2006-01-01

    We report on the chemical analysis of water samples collected from the Taylor Mountains 1:250,000-scale quadrangle. Parameters for which data are reported include pH, conductivity, water temperature, major cation and anion concentrations, trace-element concentrations, and dissolved organic-carbon concentrations. Samples were collected as part of a multiyear U.S. Geological Survey project 'Geologic and Mineral Deposit Data for Alaskan Economic Development.' Data presented here are from samples collected in June and July of 2005. The data are being released at this time with minimal interpretation. This is the second release of aqueous geochemical data from this project; 2004 aqueous geochemical data were published previously (Wang and others, 2006). The data in this report augment but do not duplicate or supersede the previous data release. Site selection was based on a regional sampling strategy that focused on first- and second-order drainages. Water sample site selection was based on landscape parameters that included physiography, wetland extent, lithological changes, and a cursory field review of mineralogy from pan concentrates. Stream water in the Taylor Mountians quadrangle is dominated by bicarbonate (HCO3-), though in a few samples more than 50 percent of the anionic charge can be attributed to sulfate (SO42-). The major-cation chemistry ranges from Ca2+/Mg2+ dominated to a mix of Ca2+/Mg2+/Na++K+. In general, good agreement was found between the major cations and anions in the duplicate samples. Many trace elements in these samples were at or near the analytical method detection limit, but good agreement was found between duplicate samples for elements with detectable concentrations. With the exception of a total mercury concentration of 0.33 ng/L detected in a field blank, field blank major-ion and trace-elements concentrations were below detection.

  2. Illuminating the NARS data entry black box: what happens between sample collection and data availability for use in assessments?

    EPA Science Inventory

    The steps between field collection of data and samples and availability of the resulting data from National Aquatic Resource Surveys (NARS) can appear to be a black box. This presentation is intended to shed some light on that process. The pathway for data depends on their source...

  3. The new Brazilian national forest inventory

    Treesearch

    Joberto V. de Freitas; Yeda M. M. de Oliveira; Doadi A. Brena; Guilherme L.A. Gomide; Jose Arimatea Silva; < i> et al< /i>

    2009-01-01

    The new Brazilian national forest inventory (NFI) is being planned to be carried out through five components: (1) general coordination, led by the Brazilian Forest Service; (2) vegetation mapping, which will serve as the basis for sample plot location; (3) field data collection; (4) landscape data collection of 10 x 10-km sample plots, based on high-resolution...

  4. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION OF SURFACE WIPE SAMPLES FOR PESTICIDES OR METALS (UA-F-8.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for collecting surface wipe samples inside a home for analysis of either metals or pesticides. This procedure covers the preparation of the surface wipe material and field activities. This protocol was followed to ensure con...

  5. Rating effectiveness of herbicides in desiccating woody vegetation

    Treesearch

    Jay R. Bentley; Charles A. Graham

    1976-01-01

    When the effectiveness of herbicide desiccants for killing and drying woody vegetation on many small test plots is rated, the standard procedures for collecting fuel moisture samples are time consuming and costly. Also, the field data often must be recorded when weather is not suitable for collecting moisture content samples. To overcome these limitations, a new...

  6. Favorable Geochemistry from Springs and Wells in Colorado

    DOE Data Explorer

    Richard E. Zehner

    2012-02-01

    This layer contains favorable geochemistry for high-temperature geothermal systems, as interpreted by Richard "Rick" Zehner. The data is compiled from the data obtained from the USGS. The original data set combines 15,622 samples collected in the State of Colorado from several sources including 1) the original Geotherm geochemical database, 2) USGS NWIS (National Water Information System), 3) Colorado Geological Survey geothermal sample data, and 4) original samples collected by R. Zehner at various sites during the 2011 field season. These samples are also available in a separate shapefile FlintWaterSamples.shp. Data from all samples were reportedly collected using standard water sampling protocols (filtering through 0.45 micron filter, etc.) Sample information was standardized to ppm (micrograms/liter) in spreadsheet columns. Commonly-used cation and silica geothermometer temperature estimates are included.

  7. Neonicotinoid Insecticide Residues in Surface Water and Soil Associated with Commercial Maize (Corn) Fields in Southwestern Ontario

    PubMed Central

    Schaafsma, Arthur; Limay-Rios, Victor; Baute, Tracey; Smith, Jocelyn; Xue, Yingen

    2015-01-01

    Neonicotinoid insecticides have come under scrutiny for their potential unintended effects on non-target organisms, particularly pollinators in agro-ecosystems. As part of a larger study of neonicotinoid residues associated with maize (corn) production, 76 water samples within or around the perimeter of 18 commercial maize fields and neighbouring apiaries were collected in 5 maize-producing counties of southwestern Ontario. Residues of clothianidin (mean = 2.28, max. = 43.60 ng/mL) and thiamethoxam (mean = 1.12, max. = 16.50 ng/mL) were detected in 100 and 98.7% of the water samples tested, respectively. The concentration of total neonicotinoid residues in water within maize fields increased six-fold during the first five weeks after planting, and returned to pre-plant levels seven weeks after planting. However, concentrations in water sampled from outside the fields were similar throughout the sampling period. Soil samples from the top 5 cm of the soil profile were also collected in these fields before and immediately following planting. The mean total neonicotinoid residue was 4.02 (range 0.07 to 20.30) ng/g, for samples taken before planting, and 9.94 (range 0.53 to 38.98) ng/g, for those taken immediately after planting. Two soil samples collected from within an conservation area contained detectable (0.03 and 0.11 ng/g) concentrations of clothianidin. Of three drifted snow samples taken, the drift stratum containing the most wind-scoured soil had 0.16 and 0.20 ng/mL mainly clothianidin in the melted snow. The concentration was at the limit of detection (0.02 ng/mL) taken across the entire vertical profile. With the exception of one sample, water samples tested had concentrations below those reported to have acute, chronic or sublethal effects to honey bees. Our results suggest that neonicotinoids may move off-target by wind erosion of contaminated soil. These results are informative to risk assessment models for other non-target species in maize agro-ecosytems. PMID:25710560

  8. Variance of discharge estimates sampled using acoustic Doppler current profilers from moving boats

    USGS Publications Warehouse

    Garcia, Carlos M.; Tarrab, Leticia; Oberg, Kevin; Szupiany, Ricardo; Cantero, Mariano I.

    2012-01-01

    This paper presents a model for quantifying the random errors (i.e., variance) of acoustic Doppler current profiler (ADCP) discharge measurements from moving boats for different sampling times. The model focuses on the random processes in the sampled flow field and has been developed using statistical methods currently available for uncertainty analysis of velocity time series. Analysis of field data collected using ADCP from moving boats from three natural rivers of varying sizes and flow conditions shows that, even though the estimate of the integral time scale of the actual turbulent flow field is larger than the sampling interval, the integral time scale of the sampled flow field is on the order of the sampling interval. Thus, an equation for computing the variance error in discharge measurements associated with different sampling times, assuming uncorrelated flow fields is appropriate. The approach is used to help define optimal sampling strategies by choosing the exposure time required for ADCPs to accurately measure flow discharge.

  9. CTEPP STANDARD OPERATING PROCEDURE FOR HANDLING MISSING SAMPLES AND DATA (SOP-2.24)

    EPA Science Inventory

    This SOP describes the method for handling missing samples or data. Missing samples or data will be identified as soon as possible during field sampling. It provides guidance to collect the missing sample or data and document the reason for the missing sample or data.

  10. Measurements of Organic Composition of Aerosol and Rainwater Samples Using Offline Aerosol Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    OBrien, R. E.; Ridley, K. J.; Canagaratna, M. R.; Croteau, P.; Budisulistiorini, S. H.; Cui, T.; Green, H. S.; Surratt, J. D.; Jayne, J. T.; Kroll, J. H.

    2016-12-01

    A thorough understanding of the sources, evolution, and budgets of atmospheric organic aerosol requires widespread measurements of the amount and chemical composition of atmospheric organic carbon in the condensed phase (within particles and water droplets). Collecting such datasets requires substantial spatial and temporal (long term) coverage, which can be challenging when relying on online measurements by state-of-the-art research-grade instrumentation (such as those used in atmospheric chemistry field studies). Instead, samples are routinely collected using relatively low-cost techniques, such as aerosol filters, for offline analysis of their chemical composition. However, measurements made by online and offline instruments can be fundamentally different, leading to disparities between data from field studies and those from more routine monitoring. To better connect these two approaches, and take advantage of the benefits of each, we have developed a method to introduce collected samples into online aerosol instruments using nebulization. Because nebulizers typically require tens to hundreds of milliliters of solution, limiting this technique to large samples, we developed a new, ultrasonic micro-nebulizer that requires only small volumes (tens of microliters) of sample for chemical analysis. The nebulized (resuspended) sample is then sent into a high-resolution Aerosol Mass Spectrometer (AMS), a widely-used instrument that provides key information on the chemical composition of aerosol particulate matter (elemental ratios, carbon oxidation state, etc.), measurements that are not typically made for collected atmospheric samples. Here, we compare AMS data collected using standard on-line techniques with our offline analysis, demonstrating the utility of this new technique to aerosol filter samples. We then apply this approach to organic aerosol filter samples collected in remote regions, as well as rainwater samples from across the US. This data provides information on the sample composition and changes in key chemical characteristics across locations and seasons.

  11. Colling Wipe Samples for VX Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koester, C; Hoppes, W G

    2010-02-11

    This standard operating procedure (SOP) provides uniform procedures for the collection of wipe samples of VX residues from surfaces. Personnel may use this procedure to collect and handle wipe samples in the field. Various surfaces, including building materials (wood, metal, tile, vinyl, etc.) and equipment, may be sampled based on this procedure. The purpose of such sampling is to determine whether or not the relevant surfaces are contaminated, to determine the extent of their contamination, to evaluate the effectiveness of decontamination procedures, and to determine the amount of contaminant that might present as a contact hazard.

  12. Field sampling and data analysis methods for development of ecological land classifications: an application on the Manistee National Forest.

    Treesearch

    George E. Host; Carl W. Ramm; Eunice A. Padley; Kurt S. Pregitzer; James B. Hart; David T. Cleland

    1992-01-01

    Presents technical documentation for development of an Ecological Classification System for the Manistee National Forest in northwest Lower Michigan, and suggests procedures applicable to other ecological land classification projects. Includes discussion of sampling design, field data collection, data summarization and analyses, development of classification units,...

  13. First report of alfalfa (Medicago sativa L.) seed rot, seedling root rot, and damping off caused by Pythium spp. in Sudanese soil

    USDA-ARS?s Scientific Manuscript database

    Alfalfa is an important forage crop in Sudan but has relatively low biomass yields. In September 2016 soil samples were collected from three commercial alfalfa production fields near Khartoum, Sudan with poor seedling establishment and rapid stand decline. Soil samples from each field were evaluated...

  14. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR FIELD USE OF THE PARTICULATE SAMPLER (UA-F-3.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the in-field use of the particulate sampling system (pumping, control unit, and size selective inlet impactors) for collecting samples of particulate matter from the air during a predetermined time period during the Arizona NHEXAS project an...

  15. Field Detection of Drugs of Abuse in Oral Fluid Using the Alere™ DDS®2 Mobile Test System with Confirmation by Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS).

    PubMed

    Krotulski, Alex J; Mohr, Amanda L A; Friscia, Melissa; Logan, Barry K

    2018-04-01

    The collection and analysis of drugs in oral fluid (OF) at the roadside has become more feasible with the introduction of portable testing devices such as the Alere™ DDS®2 Mobile Test System (DDS®2). The objective of this study was to compare the on-site results for the DDS®2 to laboratory-based confirmatory assays with respect to detection of drugs of abuse in human subjects. As part of a larger Institutional Review Board approved study, two OF samples were collected from each participant at a music festival in Miami, FL, USA. One OF sample was field screened using the DDS®2, and a confirmatory OF sample was collected using the Quantisal™ OF collection device and submitted to the laboratory for testing. In total, 124 subjects participated in this study providing two contemporaneous OF samples. DDS®2 field screening yielded positive results for delta-9-tetrahydrocannabinol (THC) (n = 27), cocaine (n = 12), amphetamine (n = 3), methamphetamine (n = 3) and benzodiazepine (n = 1). No opiate-positive OF samples were detected. For cocaine, amphetamine, methamphetamine and benzodiazepines, the DDS®2 displayed sensitivity, specificity and accuracy of 100%. For THC, the DDS®2 displayed sensitivity of 90%, specificity of 100% and accuracy of 97.5%, when the threshold for confirmation matched that of the manufacturers advertised cut-off. When this confirmatory threshold was lowered to the analytical limit of detection (i.e., 1 ng/mL), apparent device performance for THC was poorer due to additional samples testing positive by confirmatory assay that had tested negative on the DDS®2, demonstrating a need for correlation between manufacturer cut-off and analytical reporting limit. These results from drug-using subjects demonstrate the value of field-based OF testing, and illustrate the significance of selecting an appropriate confirmation cut-off concentration with respect to performance evaluation and detection of drug use.

  16. Forestry inventory based on multistage sampling with probability proportional to size

    NASA Technical Reports Server (NTRS)

    Lee, D. C. L.; Hernandez, P., Jr.; Shimabukuro, Y. E.

    1983-01-01

    A multistage sampling technique, with probability proportional to size, is developed for a forest volume inventory using remote sensing data. The LANDSAT data, Panchromatic aerial photographs, and field data are collected. Based on age and homogeneity, pine and eucalyptus classes are identified. Selection of tertiary sampling units is made through aerial photographs to minimize field work. The sampling errors for eucalyptus and pine ranged from 8.34 to 21.89 percent and from 7.18 to 8.60 percent, respectively.

  17. Acetylcholinesterase inhibition and gill lesions in Rasbora caverii, an indigenous fish inhabiting rice field associated waterbodies in Sri Lanka.

    PubMed

    Wijeyaratne, W M D N; Pathiratne, Asoka

    2006-10-01

    The present study was aimed at applying condition factor (CF), brain acetylcholinesterase (AChE) and gill histology as biomarkers for detecting possible exposure/effect induced by pesticides in fish residing rice field associated waterbodies in Sri Lanka. Biomarkers of an indigenous fish, Rasbora caverii collected from five sampling sites including canals near rice fields, a river and a reservoir (the reference site) were evaluated at four sampling stages covering pesticide application periods during rice cultivation season in 2004. Results indicated that CF of the fish did not show significant alterations regardless of the sampling sites or sampling stages. Site specific differences in AChE activities of the fish were not evident either prior to application of pesticides or at 7 days after Paraquat application to the rice fields. Two days after the application of a mixture of Fenthion and Phenthoate to the rice fields, AChE activity of the fish collected from canals near rice fields was significantly depressed (65-75%) compared to the fish in the reference site. The activities remain depressed to 50-56% even at 65 days after the insecticides application. Laboratory studies showed that prior exposure of R. caverii to Paraquat (2 microg l(-1), 7 days) enhanced the extent of inhibition of brain AChE activity induced by Fenthion (3 microg l(-1)) or a mixture of Fenthion (3 microg l(-1)) and Phenthoate (5 microg l(-1)). Gills of fish collected from canals near rice fields exhibited abnormal multiple divisions at the tips of some secondary lamellae in addition to hyperplasia, hypertrophy and club shaped deformities. Results indicate that application of pesticides in rice culture could manifest a threat to native fish populations residing rice field associated waterbodies. The response of brain AChE and histological changes in the gills of R. caverii allowed differentiating sampling sites after insecticide applications to the rice fields. Hence, R. caverii may be considered as a surrogate species in ecotoxicological risk evaluation of agrochemicals in the region.

  18. Mosquitoes (Diptera: Culicidae) Collected From Residential Yards and Dog Kennels in Florida Using Two Aspirators, a Sweep Net, or a CDC Trap.

    PubMed

    Holderman, C J; Gezan, S A; Stone, A E S; Connelly, C R; Kaufman, P E

    2018-01-10

    Mosquito surveillance typically uses Centers for Disease Control and Prevention (CDC) mosquito light traps baited with CO2. From January 2013 to March 2015, we sampled seven field sites using three active mosquito-trapping techniques (two different aspirators and a sweep net) and the stationary CO2-baited CDC mosquito light trap to determine mosquito capture efficacy for each technique. Sampling occurred in four suburban backyards and three dog kennel facilities near Gainesville, FL, USA; species collection and relative abundance were measured. A total of 32 species and 70,090 individual mosquitoes were collected, including a new record for Alachua County, Florida, Aedes hendersoni (Cockerell). The dominant (>5% of total capture) mosquito species collected during the study included Aedes atlanticus (Dyar and Knab), Aedes infirmatus (Dyar and Knab), Anopheles crucians Wiedemann, Culiseta melanura (Coquillett), Culex erraticus (Dyar and Knab), Culex nigripalpus Theobald, and Uranotaenia sapphirina (Osten Sacken). The CDC trap captured the most species (29), followed by large aspirator (28), small aspirator (26), and the sweep net (23). All dominant species were captured with each sampling technique. Excluding Wyeomyia mitchellii (Theobald), all subdominant species (1-5% of total capture) were collected with each sampling technique. Future sampling should consider the utility (e.g., large numbers are readily collected) and limitations (e.g., personnel requirements) of aspirator collections when designing field-based mosquito sampling projects, especially those in residential areas or those focused upon species captured. © The Author(s) 2017. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  19. Soil moisture determination study. [Guymon, Oklahoma

    NASA Technical Reports Server (NTRS)

    Blanchard, B. J.

    1979-01-01

    Soil moisture data collected in conjunction with aircraft sensor and SEASAT SAR data taken near Guymon, Oklahoma are summarized. In order to minimize the effects of vegetation and roughness three bare and uniformly smooth fields were sampled 6 times at three day intervals on the flight days from August 2 through 17. Two fields remained unirrigated and dry. A similar pair of fields was irrigated at different times during the sample period. In addition, eighteen other fields were sampled on the nonflight days with no field being sampled more than 24 hours from a flight time. The aircraft sensors used included either black and white or color infrared photography, L and C band passive microwave radiometers, the 13.3, 4.75, 1.6 and .4 GHz scatterometers, the 11 channel modular microwave scanner, and the PRT5.

  20. Water-Quality Data Collected from Vallecito Reservoir, Its Inflows and Outflow, Southwestern Colorado, 1999-2002

    USGS Publications Warehouse

    Ranalli, Anthony J.

    2008-01-01

    The Pine River Watershed Stakeholders Group was created in December 1997 to allow local participation in addressing water-quality issues in Los Pi?os River watershed, including Vallecito Reservoir in southwestern Colorado. One water-quality issue identified by the stakeholder group is to increase the understanding of the current water quality of Vallecito Reservoir, its two major inflows, and its outflow. The U.S. Geological Survey (USGS), in cooperation with volunteers from the Pine River Watershed Stakeholders Group and the U.S. Environmental Protection Agency (USEPA), U.S. Bureau of Reclamation (BOR), Colorado Department of Public Health and Environment (CDPHE), Pine River Irrigation District, Southern Ute Tribe, San Juan Basin Health Department, and San Juan Resource Conservation and Development, collected water-quality samples from Vallecito Reservoir, its two major inflows, and its outflow between August 1999 and November 2002 at about monthly intervals from April through November. The water-quality samples were analyzed for total and dissolved metals (aluminum, arsenic, cadmium, copper, chromium, iron, lead, manganese, mercury, nickel, silver, and zinc), dissolved major ions (calcium, magnesium, sodium, potassium, chloride, bicarbonate, and sulfate), dissolved silica, dissolved organic carbon (DOC), ultraviolet (UV) absorbance at 254 and 280 nanometers, nutrients (total organic nitrogen, dissolved organic nitrogen, dissolved ammonia, dissolved nitrate, total phosphorus, dissolved phosphorus, and orthophosphate), chlorophyll-a (reservoir only), and suspended sediment (inlets to the reservoir only). Measurements of field properties (pH, specific conductance, water temperature, and dissolved oxygen) were also made at each sampling site each time a water-quality sample was collected. This report documents (1) sampling sites and times of sample collection, (2) sample-collection methods, (3) laboratory analytical methods, and (4) responsibilities of each agency/group involved in the project. The report also provides the environmental and quality-control data collected during the project and provides an interpretation of the quality-control data (field blanks and field duplicates) to assess the quality of the environmental data. This report provides a baseline data set against which future changes in water quality can be assessed.

  1. Dust emissions of organic soils observed in the field and laboratory

    NASA Astrophysics Data System (ADS)

    Zobeck, T. M.; Baddock, M. C.; Guo, Z.; Van Pelt, R.; Acosta-Martinez, V.; Tatarko, J.

    2011-12-01

    According to the U.S. Soil Taxonomy, Histosols (also known as organic soils) are soils that are dominated by organic matter (>20% organic matter) in half or more of the upper 80 cm. These soils, when intensively cropped, are subject to wind erosion resulting in loss in crop productivity and degradation of soil, air, and water quality. Estimating wind erosion on Histosols has been determined by USDA-Natural Resources Conservation Service as a critical need for the Wind Erosion Prediction System (WEPS) model. WEPS has been developed to simulate wind erosion on agricultural land in the US, including soils with organic soil material surfaces. However, additional field measurements are needed to calibrate and validate estimates of wind erosion of organic soils using WEPS. In this study, we used a field portable wind tunnel to generate suspended sediment (dust) from agricultural surfaces for soils with a range of organic contents. The soils were tilled and rolled to provide a consolidated, friable surface. Dust emissions and saltation were measured using an isokinetic vertical slot sampler aspirated by a regulated suction source. Suspended dust was collected on filters of the dust slot sampler and sampled at a frequency of once every six seconds in the suction duct using a GRIMM optical particle size analyzer. In addition, bulk samples of airborne dust were collected using a sampler specifically designed to collect larger dust samples. The larger dust samples were analyzed for physical, chemical, and microbiological properties. In addition, bulk samples of the soils were tested in a laboratory wind tunnel similar to the field wind tunnel and a laboratory dust generator to compare field and laboratory results. For the field wind tunnel study, there were no differences between the highest and lowest organic content soils in terms of their steady state emission rate under an added abrader flux, but the soil with the mid-range of organic matter had less emission by one third. In the laboratory wind tunnel, samples with the same ratio of erodible to non-erodible aggregates as the field soils were abraded and dust emissions were observed with the same sampling system as used in the field wind tunnel. In the dust generator, 5 gm samples < 8 mm diameter of each organic soil were rotated in a 50 cm long tube and the dust generated was observed with the GRIMM during a 20 minute run. Comparisons of the field dust emission rates with the laboratory results will be presented.

  2. Pre-Mission Input Requirements to Enable Successful Sample Collection by a Remote Field/EVA Team

    NASA Technical Reports Server (NTRS)

    Cohen, B. A.; Young, K. E.; Lim, D. S.

    2015-01-01

    This paper is intended to evaluate the sample collection process with respect to sample characterization and decision making. In some cases, it may be sufficient to know whether a given outcrop or hand sample is the same as or different from previous sampling localities or samples. In other cases, it may be important to have more in-depth characterization of the sample, such as basic composition, mineralogy, and petrology, in order to effectively identify the best sample. Contextual field observations, in situ/handheld analysis, and backroom evaluation may all play a role in understanding field lithologies and their importance for return. For example, whether a rock is a breccia or a clast-laden impact melt may be difficult based on a single sample, but becomes clear as exploration of a field site puts it into context. The FINESSE (Field Investigations to Enable Solar System Science and Exploration) team is a new activity focused on a science and exploration field based research program aimed at generating strategic knowledge in preparation for the human and robotic exploration of the Moon, near-Earth asteroids (NEAs) and Phobos and Deimos. We used the FINESSE field excursion to the West Clearwater Lake Impact structure (WCIS) as an opportunity to test factors related to sampling decisions. In contract to other technology-driven NASA analog studies, The FINESSE WCIS activity is science-focused, and moreover, is sampling-focused, with the explicit intent to return the best samples for geochronology studies in the laboratory. This specific objective effectively reduces the number of variables in the goals of the field test and enables a more controlled investigation of the role of the crewmember in selecting samples. We formulated one hypothesis to test: that providing details regarding the analytical fate of the samples (e.g. geochronology, XRF/XRD, etc.) to the crew prior to their traverse will result in samples that are more likely to meet specific analytical objectives than samples collected in the absence of this premission information. We conducted three tests of this hypothesis. Our investigation was designed to document processes, tools and procedures for crew sampling of planetary targets. This is not meant to be a blind, controlled test of crew efficacy, but rather an effort to recognize the relevant variables that enter into sampling protocol and to develop recommendations for crew and backroom training in future endeavors. Methods: One of the primary FINESSE field deployment objectives was to collect impact melt rocks and impact melt-bearing breccias from a number of locations around the WCIS structure to enable high precision geochronology of the crater to be performed [1]. We conducted three tests at WCIS after two full days of team participation in field site activities, including using remote sensing data and geologic maps, hiking overland to become familiar with the terrain, and examining previously-collected samples from other islands. In addition, the team members shared their projects and techniques with the entire team. We chose our "crew members" as volunteers from the team, all of whom had had moderate training in geologic fieldwork and became familiar with the general field setting. The first two tests were short, focused tests of our hypothesis. Test A was to obtain hydrothermal vugs; Test B was to obtain impact melt and intrusive rock as well as the contact between the two to check for contact metamorphism and age differences. In both cases, the test director had prior knowledge of the site geology and had developed a study-specific objective for sampling prior to deployment. Prior to the field deployment, the crewmember was briefed on the sampling objective and the laboratory techniques that would be used on the samples. At the field sites (Fig. 2), the crewmember was given 30 minutes to survey a small section of outcrop (10-15 m) and acquire a suite of three samples. The crewmember talked through his process and the test director kept track of the timeline in verbal cues to the crewmember. At the conclusion, the team member conducting the scientific study appraised the samples and train of thought. Test C was a 90-minute EVA simulation using two crewmembers working out of line-of-sight in communication with a science backroom. The science objectives were determined by the science backroom team in advance using a Gigapan image of the outcrop (Fig. 1). The science team formulated hypotheses for the outcrop units and created sampling objectives for impact-melt lithologies; the science team turned these into a science plan, which they communicated to the crew in camp prior to crew deployment. As part of the science plan, the science team also discussed their sample needs in depth with the crewmembers, including laboratory methods, objectives, and samples sizes needed. During the deployment, the two crewmembers relayed real-time information to the science backroom by radio with no time delay. Both the crew and science team re-evaluated their hypotheses and science plans in real-time. Discussion: Upon evaluation, we found that the focused tests (Tests A and B) were successful in meeting their scientific objectives. The crewmember used their knowledge of how the samples were to be used in further study (technique, sample size, and scientific need) to focus on the sampling task. The crewmember was comfortable spending minimal time describing and mapping the outcrop. The crewmember used all available time to get a good sample. The larger test was unsuccessful in meeting the sampling objectives. When the crewmembers began describing the lithologies, it was quickly apparent that the lithologies were not as the backroom expected and had communicated to the crew. When the outcrop wasn't as expected, the crew members instinctively switched to field characterization mode, taking significant time to characterize and map the outcrop. One crew member admitted that he "kind of lost track" of the sampling strategy as he focused on the basic outcrop characterization. This is the logical first step in a field geology campaign, that a significant amount of time must be spent by the crew and backroom to understand the outcrop and its significance. Basic field characterization of an outcrop is a focused activity that takes significant time and training [2, 3]. Sampling of representational lithologies can be added to this activity for little cost [4]. However, we have shown that identification of unusual or specific samples for laboratory study also takes significant time and knowledge. We suggest that sampling of this type be considered a separate activity from field characterization, and that crewmembers be trained in sampling needs for different kinds of studies (representative lithologies vs. specialized samples) to acquire a mindset for sampling similar to field mapping. Sampling activities should be given a significant amount of specifically allocated time in scheduling EVA activities; and in the better case, that sampling be done as a second activity to a previously studied outcrop where both crew and backroom are comfortable with its context and characteristics. Our hypothesis posited that crewmember knowledge of how the samples would be used upon return would aid them in choosing relevant samples. Our testing bore this hypothesis out to some extent. We therefore recommend that crewmember training should include exposure to the laboratory techniques and analyses that will be used on the samples to foster this knowledge. There is also the potential for increasing crewmember contextual knowledge real-time in the field through the introduction of in situ geochemical technologies such as field portable XRF. The presence of field portable geochemical technology could enable the astronauts to interrogate the samples for K abundance real-time, ensuring they could collect valuable and dateable samples [5]. Though simulations such as these can teach us a fair bit about decision making processes and timeline building, one EVA participant noted that when he wasn't collecting "real" samples, he wasn't at his best. This effect suggests that higher-fidelity studies involving truly remote participants conducting actual scientific studies merit further attention to capture lessons for application to future crew situations.

  3. System and method for liquid extraction electrospray-assisted sample transfer to solution for chemical analysis

    DOEpatents

    Kertesz, Vilmos; Van Berkel, Gary J.

    2016-07-12

    A system for sampling a surface includes a surface sampling probe comprising a solvent liquid supply conduit and a distal end, and a sample collector for suspending a sample collection liquid adjacent to the distal end of the probe. A first electrode provides a first voltage to solvent liquid at the distal end of the probe. The first voltage produces a field sufficient to generate electrospray plume at the distal end of the probe. A second electrode provides a second voltage and is positioned to produce a plume-directing field sufficient to direct the electrospray droplets and ions to the suspended sample collection liquid. The second voltage is less than the first voltage in absolute value. A voltage supply system supplies the voltages to the first electrode and the second electrode. The first electrode can apply the first voltage directly to the solvent liquid. A method for sampling for a surface is also disclosed.

  4. An evaluation of soil sampling for 137Cs using various field-sampling volumes.

    PubMed

    Nyhan, J W; White, G C; Schofield, T G; Trujillo, G

    1983-05-01

    The sediments from a liquid effluent receiving area at the Los Alamos National Laboratory and soils from an intensive study area in the fallout pathway of Trinity were sampled for 137Cs using 25-, 500-, 2500- and 12,500-cm3 field sampling volumes. A highly replicated sampling program was used to determine mean concentrations and inventories of 137Cs at each site, as well as estimates of spatial, aliquoting, and counting variance components of the radionuclide data. The sampling methods were also analyzed as a function of soil size fractions collected in each field sampling volume and of the total cost of the program for a given variation in the radionuclide survey results. Coefficients of variation (CV) of 137Cs inventory estimates ranged from 0.063 to 0.14 for Mortandad Canyon sediments, whereas CV values for Trinity soils were observed from 0.38 to 0.57. Spatial variance components of 137Cs concentration data were usually found to be larger than either the aliquoting or counting variance estimates and were inversely related to field sampling volume at the Trinity intensive site. Subsequent optimization studies of the sampling schemes demonstrated that each aliquot should be counted once, and that only 2-4 aliquots out of as many as 30 collected need be assayed for 137Cs. The optimization studies showed that as sample costs increased to 45 man-hours of labor per sample, the variance of the mean 137Cs concentration decreased dramatically, but decreased very little with additional labor.

  5. Field-based Evaluation of a Novel SPME-GC-MS Method for Investigation of Below-ground Interaction between Brassica Roots and Larvae of Cabbage Root Fly, Delia radicum L.

    PubMed

    Deasy, William; Shepherd, Tom; Alexander, Colin J; Birch, A Nicholas E; Evans, K Andrew

    2016-11-01

    Collection of volatiles from plant roots poses technical challenges due to difficulties accessing the soil environment without damaging the roots. To validate a new non-invasive method for passive sampling of root volatiles in situ, from plants grown under field conditions, using solid phase micro-extraction (SPME). SPME fibres were inserted into perforated polytetrafluoroethene (PTFE) tubes positioned in the soil next to broccoli plants for collection of root volatiles pre- and post-infestation with Delia radicum larvae. After sample analysis by gas chromatography-mass spectrometry (GC-MS), principal component analysis (PCA) was applied to determine differences in the profiles of volatiles between samples. GC-MS analysis revealed that this method can detect temporal changes in root volatiles emitted before and after Delia radicum damage. PCA showed that samples collected pre- and post-infestation were compositionally different due to the presence of root volatiles induced by D. radicum feeding. Sulphur containing compounds, in particular, accounted for the differences observed. Root volatiles emission patterns post-infestation are thought to follow the feeding and developmental progress of larvae. This study shows that volatiles released by broccoli roots can be collected in situ using SPME fibres within perforated PTFE tubes under field conditions. Plants damaged by Delia radicum larvae could be distinguished from plants sampled pre-infestation and soil controls on the basis of larval feeding-induced sulphur-containing volatiles. These results show that this new method is a powerful tool for non-invasive sampling of root volatiles below-ground. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  6. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR FIELD COLLECTION OF FOOD AND BEVERAGE SAMPLES (UA-F-15.1)

    EPA Science Inventory

    The purpose of this SOP is to provide a uniform procedure for the collection of a complete (all meals, snacks, and beverages), one-day (24 hour) duplicate diet sample from the primary respondent. Participants will keep a duplicate portion of all food consumed in a 24 hour period...

  7. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION OF SURFACE WIPE SAMPLES FOR PESTICIDES OR METALS ANALYSIS (UA-F-8.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for collecting surface wipe samples inside a home for analysis of either metals or pesticides. This procedure covers the preparation of the surface wipe material and field activities. This protocol was followed to ensure con...

  8. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION OF DERMAL WIPE SAMPLES FOR PESTICIDES OR METALS (UA-F-9.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for collecting a dermal wipe sample from a participant's hands for the measurement of pesticide or metal residues on the skin. This procedure covers the preparation of the dermal wipe material and field activities. This prot...

  9. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR FIELD COLLECTION OF FOOD AND BEVERAGE SAMPLES (UA-F-15.1)

    EPA Science Inventory

    The purpose of this SOP is to provide a uniform procedure for the collection of a complete (all meals, snacks, and beverages), one-day (24 hour) duplicate diet sample from the primary respondent. Participants will keep a duplicate portion of all food consumed in a 24 hour period...

  10. Microbial Populations in Extreme Environments: Investigations and Characterizations of the Microbiology and Geochemistry of Galapagos Island Fumaroles

    NASA Astrophysics Data System (ADS)

    Mayhew, L. E.; Childers, S. E.; Geist, D.

    2005-12-01

    The extreme physiochemical conditions, insularity, and wide range in ages of fumaroles of the Galapagos Islands provide an excellent opportunity to explore for novel microorganisms and to study life in extreme environments. This is the first study that measures microbial diversity of Galapagos fumaroles. Forty-seven samples were collected from six distinct fumarole fields on Sierra Negra and Alcedo volcanoes. Vulcan Chico, on Sierra Negra, was activated during the last eruption in 1979. Two of the other fumarole fields on Sierra Negra are associated with a long-lived fault system on the caldera floor and are therefore likely to be significantly older. The fault-associated fumaroles have widespread alteration haloes (up to 100 m in diameter) and thick deposits of native sulfur. The most vigorous of the fumarole fields on Alcedo activated in late 1993 to early 1994. The second fumarole field on Alcedo is associated with a recently extinct geyser and the third is located on a rhyolite vent. A diversity of colors was observed in the substrates at all of the fumarole fields and some may be the result of microbial activity. Collection sites were chosen on the basis of temperature and the variations in the substrate in order to obtain samples from a variety of environments. Temperatures at sample sites range from 25.0 to 178.5° C, and pH from 0 to 6. The material collected varies between sites and includes crystalline sulfur deposits, clay, sandy and rocky soils, and microbial mats. Substrate material is characterized by powder x-ray diffractometry and scanning electron microscopy and gases collected from five of the fumarole fields are being analyzed to test for chemical controls on the microbial populations. Genomic DNA is being extracted from all of the samples. Primers for Bacteria and Archaea are used for PCR amplification of the 16S rRNA gene. To date, 22 of 37 processed samples have amplifiable DNA. Microbial diversity of samples possessing amplifiable DNA is being assessed by denaturing gradient gel electrophoresis (DGGE). These results may reveal the presence of novel organisms and will provide insights into how vent age, insularity, temperature, pH, and geochemistry influence the microbial populations in extreme environments in the Galapagos Islands.

  11. Comparative study of the vapor analytes of trinitrotoluene (TNT)

    NASA Astrophysics Data System (ADS)

    Edge, Cindy C.; Gibb, Julie; Dugan, Regina E.

    1998-12-01

    Trinitrotoluene (TNT) is a high explosive used in most antipersonnel and antitank landmines. The Institute for Biological Detection Systems (IBDS) has developed a quantitative vapor delivery system, termed olfactometer, for conducting canine olfactory research. The research is conducted utilizing dynamic conditions, therefore, it is imperative to evaluate the headspace of TNT to ensure consistency with the dynamic generation of vapor. This study quantified the vapor headspace of military- grade TNT utilizing two different vapor generated methodologies, static and dynamic, reflecting differences between field and laboratory environments. Static vapor collection, which closely mimics conditions found during field detection, is defined as vapor collected in an open-air environment at ambient temperature. Dynamic vapor collection incorporates trapping of gases from a high flow vapor generation cell used during olfactometer operation. Analysis of samples collected by the two methodologies was performed by gas chromatography/mass spectrometry and the results provided information with regard to the constituents detected. However, constituent concentration did vary between the sampling methods. This study provides essential information regarding the vapor constituents associated with the TNT sampled using different sampling methods. These differences may be important in determining the detection signature dogs use to recognize TNT.

  12. Water-quality data at amphibian research sites in Maryland, Washington, D.C., and Virginia, 2005-2007

    USGS Publications Warehouse

    Rice, Karen C.

    2008-01-01

    Data on the chemical composition of water were collected at least once from 47 amphibian research sites in Maryland, Washington, D.C., and Virginia, from 2005 through 2007. One hundred twenty-five water samples were collected from vernal pools and streams and analyzed as part of long-term monitoring projects of the U.S. Geological Survey Amphibian Research and Monitoring Initiative in the Northeast Region. Field measurements of water temperature, specific conductance, and pH were made. Laboratory analyses of the water samples included acid-neutralizing capacity, total Kjeldahl nitrogen (ammonium plus organic nitrogen), nitrite plus nitrate, total nitrogen, and total phosphorus concentrations. Field and laboratory analytical results of water samples and quality-assurance data are presented.

  13. Culture- and quantitative IS900 real-time PCR-based analysis of the persistence of Mycobacterium avium subsp. paratuberculosis in a controlled dairy cow farm environment.

    PubMed

    Moravkova, M; Babak, V; Kralova, A; Pavlik, I; Slana, I

    2012-09-01

    The aim of this study was to monitor the persistence of Mycobacterium avium subsp. paratuberculosis in environmental samples taken from a Holstein farm with a long history of clinical paratuberculosis. A herd of 606 head was eradicated, and mechanical cleaning and disinfection with chloramine B with ammonium (4%) was carried out on the farm; in the surrounding areas (on the field and field midden) lime was applied. Environmental samples were collected before and over a period of 24 months after destocking. Only one sample out of 48 (2%) examined on the farm (originating from a waste pit and collected before destocking) was positive for M. avium subsp. paratuberculosis by cultivation on solid medium (Herrold's egg yolk medium). The results using real-time quantitative PCR (qPCR) showed that a total of 81% of environmental samples with an average mean M. avium subsp. paratuberculosis cell number of 3.09 × 10(3) were positive for M. avium subsp. paratuberculosis before destocking compared to 43% with an average mean M. avium subsp. paratuberculosis cell number of 5.86 × 10(2) after 24 months. M. avium subsp. paratuberculosis-positive samples were detected in the cattle barn as well as in the calf barn and surrounding areas. M. avium subsp. paratuberculosis was detected from different matrices: floor and instrument scrapings, sediment, or scraping from watering troughs, waste pits, and cobwebs. M. avium subsp. paratuberculosis DNA was also detected in soil and plants collected on the field midden and the field 24 months after destocking. Although the proportion of positive samples decreased from 64% to 23% over time, the numbers of M. avium subsp. paratuberculosis cells were comparable.

  14. Culture- and Quantitative IS900 Real-Time PCR-Based Analysis of the Persistence of Mycobacterium avium subsp. paratuberculosis in a Controlled Dairy Cow Farm Environment

    PubMed Central

    Moravkova, M.; Babak, V.; Kralova, A.; Pavlik, I.

    2012-01-01

    The aim of this study was to monitor the persistence of Mycobacterium avium subsp. paratuberculosis in environmental samples taken from a Holstein farm with a long history of clinical paratuberculosis. A herd of 606 head was eradicated, and mechanical cleaning and disinfection with chloramine B with ammonium (4%) was carried out on the farm; in the surrounding areas (on the field and field midden) lime was applied. Environmental samples were collected before and over a period of 24 months after destocking. Only one sample out of 48 (2%) examined on the farm (originating from a waste pit and collected before destocking) was positive for M. avium subsp. paratuberculosis by cultivation on solid medium (Herrold's egg yolk medium). The results using real-time quantitative PCR (qPCR) showed that a total of 81% of environmental samples with an average mean M. avium subsp. paratuberculosis cell number of 3.09 × 103 were positive for M. avium subsp. paratuberculosis before destocking compared to 43% with an average mean M. avium subsp. paratuberculosis cell number of 5.86 × 102 after 24 months. M. avium subsp. paratuberculosis-positive samples were detected in the cattle barn as well as in the calf barn and surrounding areas. M. avium subsp. paratuberculosis was detected from different matrices: floor and instrument scrapings, sediment, or scraping from watering troughs, waste pits, and cobwebs. M. avium subsp. paratuberculosis DNA was also detected in soil and plants collected on the field midden and the field 24 months after destocking. Although the proportion of positive samples decreased from 64% to 23% over time, the numbers of M. avium subsp. paratuberculosis cells were comparable. PMID:22773642

  15. Highly sensitive serological methods for detecting tomato yellow leaf curl virus in tomato plants and whiteflies.

    PubMed

    Xie, Yan; Jiao, Xiaoyang; Zhou, Xueping; Liu, Huan; Ni, Yuequn; Wu, Jianxiang

    2013-05-06

    Tomato yellow leaf curl virus (TYLCV) is a member of the genus Begomovirus in the family Geminiviridae, which causes severe losses in tomato production in tropic and subtropic regions. The purified TYLCV virions were used as the immunogen to produce monoclonal antibodies (MAbs) using the hybridoma technology. MAb-based dot enzyme-linked immunosorbent assay (dot-ELISA) and direct tissue blot immunoassay (DTBIA) were developed for sensitive, simple, and rapid detection of TYLCV in field tomato and whitefly (Bemisia tabaci) samples collected from TYLCV prevalent provinces in China. Using the hybridoma technology, six murine MAbs (1C4, 8D10, 6E3, 2F2, 3F4 and 4G3) against TYLCV were prepared. Using the MAb 1C4, dot-ELISA and DTBIA were then established for detecting TYLCV in field tomato and whitefly samples collected from TYLCV prevalent provinces in China. The dot-ELISA could detect TYLCV in infected tissue crude extract diluted at 1:5,120 (w/v, g mL-1), and in viruliferous whitefly homogenate diluted at 1:128 (individual whitefly/μL), respectively. Field tomato samples (n=487) and whitefly samples (n=110) from TYLCV prevalent districts in China were screened for the presence of TYLCV using the two developed methods, and the results were further confirmed by PCR and nucleotide sequencing. The survey revealed that TYLCV is widespread on tomato plants in Zhejiang, Shandong and Henan provinces in China. The developed dot-ELISA is very suitable for the routine detection of TYLCV in field tomato and whitefly samples, and the DTBIA is more suitable for the routine detection of TYLCV in large-scale tomato plant samples collected from TYLCV prevalent areas.

  16. Fungal burden exposure assessment in podiatry clinics from Ireland.

    PubMed

    Viegas, Carla; Coggins, Ann Marie; Faria, Tiago; Caetano, Liliana Aranha; Gomes, Anita Quintal; Sabino, Raquel; Verissimo, Cristina; Roberts, Nigel; Watterson, David; MacGilchrist, Claire; Fleming, Gerard T A

    2018-03-26

    Fungi are amongst the bioaerosols of most importance, as indicated by the growing interest in this field of research. The aim was to characterize the exposure to fungal burden in podiatry clinics using culture-based and molecular methods. Airborne fungi were collected using an impaction air sampler and surface samples were also performed. Fourteen air samples were collected for direct detection of fungal DNA from filamentous fungi and dermatophytes. Overall, 63.6 % of the evening samples and 46 % of the morning samples surpassed the threshold values (150 CFU/m 3 ). Molecular detection, by real time PCR, of the target fungal species/strains (Aspergillus and Stachybotrys species) was negative for all samples collected. Trichophyton rubrum was detected by PCR analysis in one DNA sample collected on day six. Results suggest the use of both culture-based and molecular methodologies are desirable for a complete evaluation of fungal burden in this particular health care setting.

  17. Field evaluation of two novel sampling devices for collecting wild oviposition site seeking malaria vector mosquitoes: OviART gravid traps and squares of electrocuting nets.

    PubMed

    Dugassa, Sisay; Lindh, Jenny M; Lindsay, Steven W; Fillinger, Ulrike

    2016-05-10

    New sampling tools are needed for collecting exophilic malaria mosquitoes in sub-Saharan Africa to monitor the impact of vector control interventions. The OviART gravid trap and squares of electrocuting nets (e-nets) were recently developed under semi-field conditions for collecting oviposition site seeking Anopheles gambiae (sensu stricto) (s.s.). This study was designed to evaluate the efficacy of these traps for sampling malaria vectors under field conditions. Prior to field testing, two modifications to the prototype OviART gravid trap were evaluated by (i) increasing the surface area and volume of water in the artificial pond which forms part of the trap, and (ii) increasing the strength of the suction fan. Six sampling tools targeting gravid females (Box gravid trap, detergent-treated ponds, e-nets insect glue-treated ponds, sticky boards and sticky floating-acetate sheets) were compared under field conditions to evaluate their relative catching performance and to select a method for comparison with the OviART gravid trap. Finally, the trapping efficacy of the OviART gravid trap and the square of e-nets were compared with a Box gravid trap during the long rainy season in three household clusters in western Kenya. The OviART gravid trap prototype's catch size was doubled by increasing the pond size [rate ratio (RR) 1.9; 95 % confidence interval (CI) 1.1-3.4] but a stronger fan did not improve the catch. The square of e-nets performed better than the other devices, collecting three times more gravid Anopheles spp. than the Box gravid trap (RR 3.3; 95 % CI 1.4-7.6). The OviART gravid trap collections were comparable to those from the e-nets and 3.3 (95 % CI 1.5-7.0) times higher than the number of An. gambiae senso lato (s.l.) collected by the Box gravid trap. Both OviART gravid trap and squares of e-nets collected wild gravid Anopheles gambiae (s.l.) where natural habitats were within 200-400 m of the trap. Whilst the e-nets are difficult to handle and might therefore only be useful as a research device, the OviART gravid trap presents a promising new surveillance tool. Further field testing is needed in different eco-epidemiological settings to provide recommendations for its use.

  18. Interim results of quality-control sampling of surface water for the Upper Colorado River National Water-Quality Assessment Study Unit, water years 1995-96

    USGS Publications Warehouse

    Spahr, N.E.; Boulger, R.W.

    1997-01-01

    Quality-control samples provide part of the information needed to estimate the bias and variability that result from sample collection, processing, and analysis. Quality-control samples of surface water collected for the Upper Colorado River National Water-Quality Assessment study unit for water years 1995?96 are presented and analyzed in this report. The types of quality-control samples collected include pre-processing split replicates, concurrent replicates, sequential replicates, post-processing split replicates, and field blanks. Analysis of the pre-processing split replicates, concurrent replicates, sequential replicates, and post-processing split replicates is based on differences between analytical results of the environmental samples and analytical results of the quality-control samples. Results of these comparisons indicate that variability introduced by sample collection, processing, and handling is low and will not affect interpretation of the environmental data. The differences for most water-quality constituents is on the order of plus or minus 1 or 2 lowest rounding units. A lowest rounding unit is equivalent to the magnitude of the least significant figure reported for analytical results. The use of lowest rounding units avoids some of the difficulty in comparing differences between pairs of samples when concentrations span orders of magnitude and provides a measure of the practical significance of the effect of variability. Analysis of field-blank quality-control samples indicates that with the exception of chloride and silica, no systematic contamination of samples is apparent. Chloride contamination probably was the result of incomplete rinsing of the dilute cleaning solution from the outlet ports of the decaport sample splitter. Silica contamination seems to have been introduced by the blank water. Sampling and processing procedures for water year 1997 have been modified as a result of these analyses.

  19. MACRO- MICRO-PURGE SOIL GAS SAMPLING METHODS FOR THE COLLECTION OF CONTAMINANT VAPORS

    EPA Science Inventory

    Purging influence on soil gas concentrations for volatile organic compounds (VOCs), as affected by sampling tube inner diameter and sampling depth (i.e., dead-space purge volume), was evaluated at different field sites. A macro-purge sampling system consisted of a standard hollo...

  20. Field Sampling Plan/Quality Assurance Project Plan Volume I of III

    EPA Pesticide Factsheets

    This document contains procedures related to the collection and analysis of soil, sediment, groundwater, surface water, air and biota samples at GE’s Pittsfield, Massachusetts facility and at other areas.

  1. Environmental Sampling & Analytical Methods (ESAM) Program - Home

    EPA Pesticide Factsheets

    ESAM is a comprehensive program to facilitate a coordinated response to a chemical, radiochemical, biotoxin or pathogen contamination incident focusing on sample collection, processing, and analysis to provide quality results to the field.

  2. CTEPP NC DATA SUPPLEMENTAL INFORMATION ON FIELD AND LABORATORY SAMPLES

    EPA Science Inventory

    This data set contains supplemental data related to the final core analytical results table. This includes sample collection data for example sample weight, air volume, creatinine, specific gravity etc.

    The Children’s Total Exposure to Persistent Pesticides and Other Persistent...

  3. Documenting of Geologic Field Activities in Real-Time in Four Dimensions: Apollo 17 as a Case Study for Terrestrial Analogues and Future Exploration

    NASA Technical Reports Server (NTRS)

    Feist, B.; Bleacher, J. E.; Petro, N. E.; Niles, P. B.

    2018-01-01

    During the Apollo exploration of the lunar surface, thousands of still images, 16 mm videos, TV footage, samples, and surface experiments were captured and collected. In addition, observations and descriptions of what was observed was radioed to Mission Control as part of standard communications and subsequently transcribed. The archive of this material represents perhaps the best recorded set of geologic field campaigns and will serve as the example of how to conduct field work on other planetary bodies for decades to come. However, that archive of material exists in disparate locations and formats with varying levels of completeness, making it not easily cross-referenceable. While video and audio exist for the missions, it is not time synchronized, and images taken during the missions are not time or location tagged. Sample data, while robust, is not easily available in a context of where the samples were collected, their descriptions by the astronauts are not connected to them, or the video footage of their collection (if available). A more than five year undertaking to reconstruct and reconcile the Apollo 17 mission archive, from launch through splashdown, has generated an integrated record of the entire mission, resulting in searchable, synchronized image, voice, and video data, with geologic context provided at the time each sample was collected. Through www.apollo17.org the documentation of the field investigation conducted by the Apollo 17 crew is presented in chronologic sequence, with additional context provided by high-resolution Lunar Reconnaissance Orbiter Camera (LROC) Narrow Angle Camera (NAC) images and a corresponding digital terrain model (DTM) of the Taurus-Littrow Valley.

  4. Groundwater conditions and studies in the Augusta–Richmond County area, Georgia, 2008–2009

    USGS Publications Warehouse

    Gonthier, Gerard; Lawrence, Stephen J.; Peck, Michael F.; Holloway, O. Gary

    2011-01-01

    Groundwater studies and monitoring efforts conducted during 2008–2009, as part of the U.S. Geological Survey (USGS) Cooperative Water Program with the City of Augusta in Richmond County, Georgia, provided data for the effective management of local water resources. During 2008–2009 the USGS completed: (1) installation of three monitoring wells and the collection of lithologic and geophysical logging data to determine the extent of hydrogeologic units, (2) collection of continuous groundwater-level data from wells near Well Fields 2 and 3, (3) collection of synoptic groundwater-level measurements and construction of potentiometric-surface maps in Richmond County to establish flow gradients and groundwater-flow directions in the Dublin and Midville aquifer systems, (4) completion of a 24-hour aquifer test to determine hydraulic characteristics of the lower Dublin aquifer, and upper and lower Midville aquifers in Well Field 2, and (5) collection of groundwater samples from selected wells in Well Field 2 for laboratory analysis of volatile organic compounds and groundwater tracers to assess groundwater quality and estimate the time of groundwater recharge. Potentiometric-surface maps of the Dublin and Midville aquifer systems for 2008–2009 indicate that the general groundwater flow direction within Richmond County is eastward toward the Savannah River, with the exception of the area around Well Field 2, where pumping interrupts the eastward flow of water toward the Savannah River and causes flow lines to bend toward the center of pumping. Results from a 24-hour aquifer test conducted in 2009 within the upper and lower Midville aquifers at Well Field 2 indicated a transmissivity and storativity for the upper and lower Midville aquifers, combined, of 4,000 feet-squared per day and 2x10-4, respectively. The upper and lower Midville aquifers and the middle lower Midville confining unit, which is 85-feet thick in this area, yielded horizontal hydraulic conductivity and specific storage values of about 45 feet per day and 2x10-6 ft-1, respectively. Results from the 24-hour aquifer test also indicate a low horizontal hydraulic conductivity for the lower Dublin aquifer of less than 1 foot per day. Of the 35 volatile organic compounds (VOCs) analyzed in 23 groundwater samples during 2008–2009, only six were detected above laboratory reporting limits in samples from eight wells. No concentration in groundwater samples collected during 2008–2009 exceeded drinking water standards. Trichloroethene had the maximum VOC concentration (1.9 micrograms per liter) collected from a water sample during 2008–2009. Water-quality sampling of several wells near Well Field 2 indicate that, while in operation, the northernmost production well might have diverted groundwater, containing low levels of trichloroethene from at least two other production wells. Analysis of sulfur hexafluoride data indicate the average year of recharge ranges between 1981 and 1984 for water samples from five wells open to the upper and lower Midville aquifers, and 1991 for a water sample from one shallow well open to the lower Dublin aquifer. All of these ages suggest a short flow path and nearby source of contamination. The actual source of low levels of VOCs at Well Field 2 remains unknown. Three newly installed monitoring wells indicate that hydrogeologic units beneath Well Fields 2 and 3 are composed of sand and clay layers. Hydrogeologic units, encountered at Well Field 2, in order of increasing depth are the lower Dublin confining unit, lower Dublin aquifer, upper Midville confining unit, upper Midville aquifer, lower Midville confining unit, and lower Midville aquifer. West of Well Field 3, hydrogeologic units, in order of increasing depth are the Upper Three Runs aquifer, Gordon confining unit, Gordon aquifer, lower Dublin confining unit, lower Dublin aquifer, upper Midville confining unit, upper Midville aquifer, lower Midville confining unit, and lower Midville aquifer.

  5. Measurement of soil moisture trends with airborne scatterometers. [Guymon, Oklahoma and Dalhart, Texas

    NASA Technical Reports Server (NTRS)

    Jones, C. L.; Mcfarland, M. J.; Rosethal, W. D.; Theis, S. W. (Principal Investigator)

    1982-01-01

    In an effort to investigate aircraft multisensor responses to soil moisture and vegetation in agricultural fields, an intensive ground sampling program was conducted in Guymon, Oklahoma and Dalhart, Texas in conjunction with aircraft data collected for visible/infrared and passive and active microwave systems. Field selections, sampling techniques, data processing, and the aircraft schedule are discussed for both sites. Field notes are included along with final (normalized and corrected) data sets.

  6. Water Quality & Pollutant Source Monitoring: Field and Laboratory Procedures. Training Manual.

    ERIC Educational Resources Information Center

    Office of Water Program Operations (EPA), Cincinnati, OH. National Training and Operational Technology Center.

    This training manual presents material on techniques and instrumentation used to develop data in field monitoring programs and related laboratory operations concerned with water quality and pollution monitoring. Topics include: collection and handling of samples; bacteriological, biological, and chemical field and laboratory methods; field…

  7. A portable vacuum for collecting arthropods from drop cloths.

    Treesearch

    H.G. Paul; R.R. Mason

    1985-01-01

    A hand-held vacuum modified for collecting insects and spiders in the field is described. The vacuum with battery is mounted on a lightweight pack-frame and is portable and versatile. It is especially useful for collecting arthropods that are dislodged from foliage samples and drop onto cloths.

  8. Characteristics and Use of Personal Collections

    ERIC Educational Resources Information Center

    Soper, Mary Ellen

    1976-01-01

    A study of the characteristics of personal collections of a sample of authors drawn from the general fields of the sciences, social sciences, and humanities, and the relationship between the size and composition of their collections and the location of works referred to in certain of their recent papers. (Author)

  9. Quality-control results for ground-water and surface-water data, Sacramento River Basin, California, National Water-Quality Assessment, 1996-1998

    USGS Publications Warehouse

    Munday, Cathy; Domagalski, Joseph L.

    2003-01-01

    Evaluating the extent that bias and variability affect the interpretation of ground- and surface-water data is necessary to meet the objectives of the National Water-Quality Assessment (NAWQA) Program. Quality-control samples used to evaluate the bias and variability include annual equipment blanks, field blanks, field matrix spikes, surrogates, and replicates. This report contains quality-control results for the constituents critical to the ground- and surface-water components of the Sacramento River Basin study unit of the NAWQA Program. A critical constituent is one that was detected frequently (more than 50 percent of the time in blank samples), was detected at amounts exceeding water-quality standards or goals, or was important for the interpretation of water-quality data. Quality-control samples were collected along with ground- and surface-water samples during the high intensity phase (cycle 1) of the Sacramento River Basin NAWQA beginning early in 1996 and ending in 1998. Ground-water field blanks indicated contamination of varying levels of significance when compared with concentrations detected in environmental ground-water samples for ammonia, dissolved organic carbon, aluminum, and copper. Concentrations of aluminum in surface-water field blanks were significant when compared with environmental samples. Field blank samples collected for pesticide and volatile organic compound analyses revealed no contamination in either ground- or surface-water samples that would effect the interpretation of environmental data, with the possible exception of the volatile organic compound trichloromethane (chloroform) in ground water. Replicate samples for ground water and surface water indicate that variability resulting from sample collection, processing, and analysis was generally low. Some of the larger maximum relative percentage differences calculated for replicate samples occurred between samples having lowest absolute concentration differences and(or) values near the reporting limit. Surrogate recoveries for pesticides analyzed by gas chromatography/mass spectrometry (GC/MS), pesticides analyzed by high performance liquid chromatography (HPLC), and volatile organic compounds in ground- and surface-water samples were within the acceptable limits of 70 to 130 percent and median recovery values between 82 and 113 percent. The recovery percentages for surrogate compounds analyzed by HPLC had the highest standard deviation, 20 percent for ground-water samples and 16 percent for surface-water samples, and the lowest median values, 82 percent for ground-water samples and 91 percent for surface-water samples. Results were consistent with the recovery results described for the analytical methods. Field matrix spike recoveries for pesticide compounds analyzed using GC/MS in ground- and surface-water samples were comparable with published recovery data. Recoveries of carbofuran, a critical constituent in ground- and surface-water studies, and desethyl atrazine, a critical constituent in the ground-water study, could not be calculated because of problems with the analytical method. Recoveries of pesticides analyzed using HPLC in ground- and surface-water samples were generally low and comparable with published recovery data. Other methodological problems for HPLC analytes included nondetection of the spike compounds and estimated values of spike concentrations. Recovery of field matrix spikes for volatile organic compounds generally were within the acceptable range, 70 and 130 percent for both ground- and surface-water samples, and median recoveries from 62 to 127 percent. High or low recoveries could be related to errors in the field, such as double spiking or using spike solution past its expiration date, rather than problems during analysis. The methodological changes in the field spike protocol during the course of the Sacramento River Basin study, which included decreasing the amount of spike solu

  10. USGS Arctic Ocean Carbon Cruise 2012: Field Activity L-01-12-AR to collect carbon data in the Arctic Ocean, August-September 2012

    USGS Publications Warehouse

    Robbins, Lisa L.; Wynn, Jonathan; Knorr, Paul O.; Onac, Bogdan; Lisle, John T.; McMullen, Katherine Y.; Yates, Kimberly K.; Byrne, Robert H.; Liu, Xuewu

    2014-01-01

    During the cruise, underway continuous and discrete water samples were collected, and discrete water samples were collected at stations to document the carbonate chemistry of the Arctic waters and quantify the saturation state of seawater with respect to calcium carbonate. These data are critical for providing baseline information in areas where no data have existed prior and will also be used to test existing models and predict future trends.

  11. Measurements of Light Absorbing Particles on Tropical South American Glaciers

    NASA Astrophysics Data System (ADS)

    Schmitt, C. G.; All, J.; Schwarz, J. P.; Arnott, W. P.; Warthon, J.; Andrade, M.; Celestian, A. J.; Hoffmann, D.; Cole, R. J.; Lapham, E.; Horodyskyj, U. N.; Froyd, K. D.; Liao, J.

    2014-12-01

    Glaciers in the tropical Andes have been losing mass rapidly in recent decades. In addition to the documented increase in temperature, increases in light absorbing particulates deposited on glaciers could be contributing to the observed glacier loss. Here we present results of measurements of light absorbing particles from glaciers in Peru and Bolivia. Samples have been collected by American Climber Science Program volunteers and scientists at altitudes up to 6770 meters. Collected snow samples were melted and filtered in the field. A new inexpensive technique, the Light Absorption Heating Method (LAHM) has been developed for analysis of light absorbing particles collected on filters. Results from LAHM analysis are calibrated using filters with known amounts of fullerene soot, a common industrial surrogate for black carbon (BC). For snow samples collected at the same field location LAHM analysis and measurements from the Single Particle Soot Photometer (SP2) instrument are well correlated (r2 = 0.92). Co-located SP2 and LAHM filter analysis suggest that BC could be the dominant absorbing component of the light absorbing particles in some areas.

  12. On sampling biases arising from insufficient bottle flushing

    NASA Astrophysics Data System (ADS)

    Codispoti, L. A.; Paver, C. R.

    2016-02-01

    Collection of representative water samples using carousel bottles is important for accurately determining biological and chemical gradients. The development of more technologically advanced instrumentation and sampling apparatus causes sampling packages to increase and "soak times" to decrease, increasing the probability that insufficient bottle flushing will produce biased results. Qualitative evidence from various expeditions suggest that insufficient flushing may be a problem. Here we report on multiple field experiments that were conducted to better quantify the errors that can arise from insufficient bottle flushing. Our experiments suggest that soak times of more than 2 minutes are sometimes required to collect a representative sample.

  13. CTEPP-OH DATA SUPPLEMENTAL INFORMATION ON FIELD AND LABORATORY SAMPLES

    EPA Science Inventory

    This data set contains supplemental data related to the final core analytical results table for CTEPP-OH. This includes sample collection data for example sample weight, air volume, creatinine, specific gravity etc.

    The Children’s Total Exposure to Persistent Pesticides and Oth...

  14. Chemical and microbiological water quality of subsurface agricultural drains during a field trial of liquid dairy manure effluent application rate and varying tillage practices, Upper Tiffin Watershed, southeastern Michigan

    USGS Publications Warehouse

    Haack, Sheridan Kidd; Duris, Joseph W.

    2008-01-01

    A field trial was done in the Upper Tiffin River Watershed, in southeastern Michigan, to determine the influence of liquid dairy manure effluent (LDME) management practices on the quality of agricultural subsurface-drain water. Samples from subsurface drains were analyzed for nutrients, fecal-coliform and Escherichia coli (E. coli) bacteria, antibiotics, chemicals typically detected in wastewater, and the occurrence of genes indicating the presence of shiga-toxin-producing E. coli, or of bovine-specific Bacteroidetes bacteria. Samples were collected from November 2, 2006, to March 20, 2007, from eight subsurface drains under field plots that received no LDME and no tillage (controls) or received 4,000 or 8,000 gallons per acre (gal/acre) of LDME and either no tillage or two different types of tillage. The two types of tillage tested were (1) ground-driven, rotary, subsurface cultivation and (2) rolling-tine aeration. Samples were collected before LDME application and at 4 hours, and 1, 2, 6, 7, and 14 days post-application. Nutrient concentrations were high in subsurface-drain water throughout the field-trial period and could not be attributed to the field-trial LDME application. Of the 59 drain-water samples, including those collected before LDME application and control samples for each date, 56 had concentrations greater than the U.S. Environmental Protection Agency (USEPA), Ecoregion VI recommended surface-water criterion for total phosphorus, and all samples had concentrations greater than the recommended total nitrogen criterion. Nitrate + nitrite nitrogen concentration exceeded 20 milligrams per liter for every sample and contributed most to the total nitrogen concentrations. Substantial increases in drain-water concentrations of organic and ammonia nitrogen and total phosphorus were found for all treatments, including controls, at 14 days post-application after 0.84 inch of rainfall over 2 days. E. coli concentrations exceeded the USEPA recreational-water-quality single-sample criterion of 235 colony forming units per 100 milliliters in only 3 of 56 samples. Of these three samples, two were collected within 1 day post-LDME application from the treatment receiving 8,000 gal/acre LDME with no tillage (NT8000). The third sample was from the rolling-tine aerator treatment with 4,000 gal/acre LDME application rate after the first significant rainfall. Two wastewater chemicals and two bacterial genes (eaeA and stx1) detected in the LDME, but absent in field blank or pre-application samples, were detected in the 4-hour or 1-day postapplication NT8000 samples. No LDME-associated chemicals were detected in later samples from the NT8000 treatment, and none were detected in samples from other treatments after the first significant rainfall. Results of this field trial were somewhat equivocal with respect to the influence of LDME concentration and tillage practices on subsurface-drain water quality, both immediately after LDME application and in the longer term, after significant rainfall. Interpretation of study findings is limited by the fact that treatments were not replicated, and flow rate or discharge from the subsurface drains was not measured. Nevertheless, study results provide useful information about nutrient and bacteria concentrations in subsurface drains during the non-growing season. In addition, study results demonstrate some potential for the use of chemical and microbiological indicators of LDME transport to subsurface drains.

  15. Aqueous geochemical data from the analysis of stream-water samples collected in June and August 2008—Taylor Mountains 1:250,000- and Dillingham D-4 1:63,360-scale quadrangles, Alaska

    USGS Publications Warehouse

    Wang, Bronwen; Owens, Victoria; Bailey, Elizabeth; Lee, Greg

    2011-01-01

    We report on the chemical analysis of water samples collected from the Taylor Mountains 1:250,000- and Dillingham D-4 1:63,360-scale quadrangles, Alaska. Reported parameters include pH, conductivity, water temperature, major cation and anion concentrations, and trace-element concentrations. We collected the samples as part of a multiyear U.S. Geological Survey project entitled "Geologic and Mineral Deposit Data for Alaskan Economic Development." Data presented here are from samples collected in June and August 2008. Minimal interpretation accompanies this data release. This is the fourth release of aqueous geochemical data from this project; data from samples collected in 2004, 2005, and 2006 were published previously. The data in this report augment but do not duplicate or supersede the previous data releases. Site selection was based on a regional sampling strategy that focused on first- and second-order drainages. Water sample sites were selected on the basis of landscape parameters that included physiography, wetland extent, lithological changes, and a cursory field review of mineralogy from pan concentrates. Stream water in the study area is dominated by bicarbonate (HCO3-), although in a few samples more than 50 percent of the anionic charge can be attributed to sulfate (SO42-). The major-cation chemistry of these samples ranges from Ca2+-Mg2+ dominated to a mix of Ca2+-Mg2+-Na++K2+. In most cases, analysis of duplicate samples showed good agreement for the major cation and major anions with the exception of the duplicate samples at site 08TA565. At site 08TA565, Ca, Mg, Cl, and CaCO3 exceeded 25 percent and the concentrations of trace elements As, Fe and Mn also exceeded 25 percent in this duplicate pair. Chloride concentration varied by more than 25 percent in 5 of the 11 duplicated samples. Trace-element concentrations in these samples generally were at or near the detection limit for the method used and, except for Co at site 08TA565, generally good agreement was determined between duplicate samples for elements with detectable concentrations. Major-ion concentrations were below detection limits in all field blanks, and the trace-element concentrations also were generally below detection limits; however, Co, Mn, Na, Zn, Cl, and Hg were detected in one or more field blank samples.

  16. A comparison of cation sampling in forest soils by tension and tension-free lysimeters

    Treesearch

    James H. Miller

    1981-01-01

    Field tests conducted in two soils with ceramic cup, ceramic plate, and tension-free lysimeters showed no concentration differences in collected cations (Ca, Mg, K, Na) between cups and plates, except for the hydrogen ion. Mean pH was 0.6 lower in cup collected samples for a sandy loam profile. Tension-free lysimeters of the design tested had persistent contamination...

  17. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION OF DERMAL WIPE SAMPLES FOR PESTICIDES AND METALS ANALYSIS (UA-F-9.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for collecting a dermal wipe sample from a participant's hands for the measurement of pesticide or metal residues on the skin. This procedure covers the preparation of the dermal wipe material and field activities. This prot...

  18. Rapid Measurement of Soil Carbon in Rice Paddy Field of Lombok Island Indonesia Using Near Infrared Technology

    NASA Astrophysics Data System (ADS)

    Kusumo, B. H.; Sukartono, S.; Bustan, B.

    2018-02-01

    Measuring soil organic carbon (C) using conventional analysis is tedious procedure, time consuming and expensive. It is needed simple procedure which is cheap and saves time. Near infrared technology offers rapid procedure as it works based on the soil spectral reflectance and without any chemicals. The aim of this research is to test whether this technology able to rapidly measure soil organic C in rice paddy field. Soil samples were collected from rice paddy field of Lombok Island Indonesia, and the coordinates of the samples were recorded. Parts of the samples were analysed using conventional analysis (Walkley and Black) and some other parts were scanned using near infrared spectroscopy (NIRS) for soil spectral collection. Partial Least Square Regression (PLSR) Models were developed using data of soil C analysed using conventional analysis and data from soil spectral reflectance. The models were moderately successful to measure soil C in rice paddy field of Lombok Island. This shows that the NIR technology can be further used to monitor the C change in rice paddy soil.

  19. Remedial investigation sampling and analysis plan for J-Field, Aberdeen Proving Ground, Maryland. Volume 1: Field Sampling Plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Benioff, P.; Biang, R.; Dolak, D.

    1995-03-01

    The Environmental Management Division (EMD) of Aberdeen Proving Ground (APG), Maryland, is conducting a remedial investigation and feasibility study (RI/FS) of the J-Field area at APG pursuant to the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA), as amended. J-Field is within the Edgewood Area of APG in Harford County, Maryland (Figure 1. 1). Since World War II activities in the Edgewood Area have included the development, manufacture, testing, and destruction of chemical agents and munitions. These materials were destroyed at J-Field by open burning and open detonation (OB/OD). Considerable archival information about J-Field exists as a result of effortsmore » by APG staff to characterize the hazards associated with the site. Contamination of J-Field was first detected during an environmental survey of the Edgewood Area conducted in 1977 and 1978 by the US Army Toxic and Hazardous Materials Agency (USATHAMA) (predecessor to the US Army Environmental Center [AEC]). As part of a subsequent USATHAMA -environmental survey, 11 wells were installed and sampled at J-Field. Contamination at J-Field was also detected during a munitions disposal survey conducted by Princeton Aqua Science in 1983. The Princeton Aqua Science investigation involved the installation and sampling of nine wells and the collection and analysis of surficial and deep composite soil samples. In 1986, a Resource Conservation and Recovery Act (RCRA) permit (MD3-21-002-1355) requiring a basewide RCRA Facility Assessment (RFA) and a hydrogeologic assessment of J-Field was issued by the US Environmental Protection Agency (EPA). In 1987, the US Geological Survey (USGS) began a two-phased hydrogeologic assessment in data were collected to model, groundwater flow at J-Field. Soil gas investigations were conducted, several well clusters were installed, a groundwater flow model was developed, and groundwater and surface water monitoring programs were established that continue today.« less

  20. Field Methods and Sample Collection Techniques for the Surveillance of West Nile Virus in Avian Hosts.

    PubMed

    Wheeler, Sarah S; Boyce, Walter M; Reisen, William K

    2016-01-01

    Avian hosts play an important role in the spread, maintenance, and amplification of West Nile virus (WNV). Avian susceptibility to WNV varies from species to species thus surveillance efforts can focus both on birds that survive infection and those that succumb. Here we describe methods for the collection and sampling of live birds for WNV antibodies or viremia, and methods for the sampling of dead birds. Target species and study design considerations are discussed.

  1. Assessing the Biological Safety Profession's Evaluation and Control of Risks Associated with the Field Collection of Potentially Infectious Specimens.

    PubMed

    Patlovich, Scott J; Emery, Robert J; Whitehead, Lawrence W; Brown, Eric L; Flores, Rene

    2015-03-01

    Because the origins of the biological safety profession are rooted in the control and prevention of laboratory-associated infections, the vocation focuses primarily on the safe handling of specimens within the laboratory. But in many cases, the specimens and samples handled in the lab are originally collected in the field where a broader set of possible exposure considerations may be present, each with varying degrees of controllability. The failure to adequately control the risks associated with collecting biological specimens in the field may result in illness or injury, and could have a direct impact on laboratory safety, if infectious specimens were packaged or transported inappropriately, for example. This study developed a web-based survey distributed to practicing biological safety professionals to determine the prevalence of and extent to which biological safety programs consider and evaluate field collection activities. In cases where such issues were considered, the data collected characterize the types of controls and methods of oversight at the institutional level that are employed. Sixty-one percent (61%) of the survey respondents indicated that research involving the field collection of biological specimens is conducted at their institutions. A majority (79%) of these field collection activities occur at academic institutions. Twenty-seven percent (27%) of respondents indicated that their safety committees do not consider issues related to biological specimens collected in the field, and only 25% with an oversight committee charged to review field collection protocols have generated a field research-specific risk assessment form to facilitate the assembly of pertinent information for a project risk assessment review. The results also indicated that most biosafety professionals (73% overall; 71% from institutions conducting field collection activities) have not been formally trained on the topic, but many (64% overall; 87% from institutions conducting field collection activities) indicated that training on field research safety issues would be helpful, and even more (71% overall; 93% from institutions conducting field collection activities) would consider participation in such a training course. Results obtained from this study can be used to develop a field research safety toolkit and associated training curricula specifically targeted to biological safety professionals.

  2. Quality-Assurance/Quality-Control Manual for Collection and Analysis of Water-Quality Data in the Ohio District, US Geological Survey

    USGS Publications Warehouse

    Francy, D.S.; Jones, A.L.; Myers, Donna N.; Rowe, G.L.; Eberle, Michael; Sarver, K.M.

    1998-01-01

    The U.S. Geological Survey (USGS), Water Resources Division (WRD), requires that quality-assurance/quality-control (QA/QC) activities be included in any sampling and analysis program. Operational QA/QC procedures address local needs while incorporating national policies. Therefore, specific technical policies were established for all activities associated with water-quality project being done by the Ohio District. The policies described in this report provide Ohio District personnel, cooperating agencies, and others with a reference manual on QA/QC procedures that are followed in collecitng and analyzing water-quality samples and reporting water-quality information in the Ohio District. The project chief, project support staff, District Water-Quality Specialist, and District Laboratory Coordinator are all involved in planning and implementing QA/QC activities at the district level. The District Chief and other district-level managers provide oversight, and the Regional Water-Quality Specialist, Office of Water Quality (USGS headquarters), and the Branch of Quality Systems within the Office of Water Quality create national QA/QC polices and provide assistance to District personnel. In the literature, the quality of all measurement data is expressed in terms of precision, variability, bias, accuracy, completeness, representativeness, and comparability. In the Ohio District, bias and variability will be used to describe quality-control data generated from samples in the field and laboratory. Each project chief must plan for implementation and financing of QA/QC activities necessary to achieve data-quality objectives. At least 15 percent of the total project effort must be directed toward QA/QC activities. Of this total, 5-10 percent will be used for collection and analysis of quality-control samples. This is an absolute minimum, and more may be required based on project objectives. Proper techniques must be followed in the collection and processing of surface-water, ground-water, biological, precipitation, bed-sediment, bedload, suspended-sediment, and solid-phase samples. These techniques are briefly described in this report and are extensively documented. The reference documents listed in this report will be kept by the District librarian and District Water-Quality Specialist and updated regularly so that they are available to all District staff. Proper handling and documentation before, during, and after field activities are essential to ensure the integrity of the sample and to correct erroneous reporting of data results. Field sites are to be properly identified and entered into the data base before field data-collection activities begin. During field activities, field notes are to be completed and sample bottles appropriately labeled a nd stored. After field activities, all paperwork is to be completed promptly and samples transferred to the laboratory within allowable holding times. All equipment used by District personnel for the collection and processing of water-quality samples is to be properly operated, maintained, and calibrated by project personnel. This includes equipment for onsite measurement of water-quality characteristics (temperature, specific conductance, pH, dissolved oxygen, alkalinity, acidity, and turbidity) and equipment and instruments used for biological sampling. The District Water-Quality Specialist and District Laboratory Coordinator are responsible for preventive maintenance and calibration of equipment in the Ohio District laboratory. The USGS National Water Quality Laboratory in Arvada, Colo., is the primary source of analytical services for most project work done by the Ohio District. Analyses done at the Ohio District laboratory are usually those that must be completed within a few hours of sample collection. Contract laboratories or other USGS laboratories are sometimes used instead of the NWQL or the Ohio District laboratory. When a contract laboratory is used, the projec

  3. COMPARISON OF LABORATORY SUBSAMPLING METHODS OF BENTHIC SAMPLES FROM BOATABLE RIVERS USING ACTUAL AND SIMULATED COUNT DATA

    EPA Science Inventory

    We examined the effects of using a fixed-count subsample of 300 organisms on metric values using macroinvertebrate samples collected with 3 field sampling methods at 12 boatable river sites. For each sample, we used metrics to compare an initial fixed-count subsample of approxima...

  4. Survalytics: An Open-Source Cloud-Integrated Experience Sampling, Survey, and Analytics and Metadata Collection Module for Android Operating System Apps

    PubMed Central

    Mackey, Sean

    2016-01-01

    Background We describe here Survalytics, a software module designed to address two broad areas of need. The first area is in the domain of surveys and app analytics: developers of mobile apps in both academic and commercial environments require information about their users, as well as how the apps are being used, to understand who their users are and how to optimally approach app development. The second area of need is in the field of ecological momentary assessment, also referred to as experience sampling: researchers in a wide variety of fields, spanning from the social sciences to psychology to clinical medicine, would like to be able to capture daily or even more frequent data from research subjects while in their natural environment. Objective Survalytics is an open-source solution for the collection of survey responses as well as arbitrary analytic metadata from users of Android operating system apps. Methods Surveys may be administered in any combination of one-time questions and ongoing questions. The module may be deployed as a stand-alone app for experience sampling purposes or as an add-on to existing apps. The module takes advantage of free-tier NoSQL cloud database management offered by the Amazon Web Services DynamoDB platform to package a secure, flexible, extensible data collection module. DynamoDB is capable of Health Insurance Portability and Accountability Act compliant storage of personal health information. Results The provided example app may be used without modification for a basic experience sampling project, and we provide example questions for daily collection of blood glucose data from study subjects. Conclusions The module will help researchers in a wide variety of fields rapidly develop tailor-made Android apps for a variety of data collection purposes. PMID:27261155

  5. Survalytics: An Open-Source Cloud-Integrated Experience Sampling, Survey, and Analytics and Metadata Collection Module for Android Operating System Apps.

    PubMed

    O'Reilly-Shah, Vikas; Mackey, Sean

    2016-06-03

    We describe here Survalytics, a software module designed to address two broad areas of need. The first area is in the domain of surveys and app analytics: developers of mobile apps in both academic and commercial environments require information about their users, as well as how the apps are being used, to understand who their users are and how to optimally approach app development. The second area of need is in the field of ecological momentary assessment, also referred to as experience sampling: researchers in a wide variety of fields, spanning from the social sciences to psychology to clinical medicine, would like to be able to capture daily or even more frequent data from research subjects while in their natural environment. Survalytics is an open-source solution for the collection of survey responses as well as arbitrary analytic metadata from users of Android operating system apps. Surveys may be administered in any combination of one-time questions and ongoing questions. The module may be deployed as a stand-alone app for experience sampling purposes or as an add-on to existing apps. The module takes advantage of free-tier NoSQL cloud database management offered by the Amazon Web Services DynamoDB platform to package a secure, flexible, extensible data collection module. DynamoDB is capable of Health Insurance Portability and Accountability Act compliant storage of personal health information. The provided example app may be used without modification for a basic experience sampling project, and we provide example questions for daily collection of blood glucose data from study subjects. The module will help researchers in a wide variety of fields rapidly develop tailor-made Android apps for a variety of data collection purposes.

  6. USGS/EPA collection protocol for bacterial pathogens in soil

    USGS Publications Warehouse

    Griffin, Dale W.; Shaefer, F.L.; Charlena Bowling,; Dino Mattorano,; Tonya Nichols,; Erin Silvestri,

    2014-01-01

    This Sample Collection Procedure (SCP) describes the activities and considerations for the collection of bacterial pathogens from representative surface soil samples (0-5 cm). This sampling depth can be reached without the use of a drill rig, direct-push technology, or other mechanized equipment. This procedure can be used in most soil types but is limited to sampling at or near the ground surface. This protocol has components for two different types of sampling applications: (1) typical sampling, when there is no suspicion of contamination (e.g., surveillance or background studies); and (2) in response to known or suspected accidental contamination (e.g., the presence of animal carcasses). This protocol does not cover sampling in response to a suspected bioterrorist or intentional release event. Surface material is removed to the required depth (0-5 cm) and clean trowel or 50 ml sample tube is used to collect the sample. Sample containers are sealed, bagged, and shipped to the laboratory for analysis. Associated documentation, including a Field Data Log and Chain-of-Custody are also included in this document.

  7. Draft Genome Sequences of Two Janthinobacterium lividum Strains, Isolated from Pristine Groundwater Collected from the Oak Ridge Field Research Center

    PubMed Central

    Wu, Xiaoqin; Deutschbauer, Adam M.; Kazakov, Alexey E.; Wetmore, Kelly M.; Cwick, Bryson A.; Walker, Robert M.; Novichkov, Pavel S.; Arkin, Adam P.

    2017-01-01

    ABSTRACT We present here the draft genome sequences of two Janthinobacterium lividum strains, GW456P and GW458P, isolated from groundwater samples collected from a background site at the Oak Ridge Field Research Center. Production of a purple pigment by these two strains was observed when grown on diluted (1/10) LB agar plates. PMID:28663297

  8. 2010 Biometrics Conference Held in Arlington, Virginia on January 20-21, 2010

    DTIC Science & Technology

    2010-01-21

    testing of mobile biometric collection devices during future biometric field exercises, we hope to provide NOVARIS officials connectivity and an...environmental factors – Extreme Outdoor Mobile Conditions – Non-cooperative users – Field-collected samples of mixed quality – Real-time access to match results...Physics: Mobile 10-print Slap Capture Robust Face/Iris Capture Contactless Fingerprints 10 Human Factors Behavioral Sciences Division The Hard

  9. Nutrient and pesticide contamination bias estimated from field blanks collected at surface-water sites in U.S. Geological Survey Water-Quality Networks, 2002–12

    USGS Publications Warehouse

    Medalie, Laura; Martin, Jeffrey D.

    2017-08-14

    Potential contamination bias was estimated for 8 nutrient analytes and 40 pesticides in stream water collected by the U.S. Geological Survey at 147 stream sites from across the United States, and representing a variety of hydrologic conditions and site types, for water years 2002–12. This study updates previous U.S. Geological Survey evaluations of potential contamination bias for nutrients and pesticides. Contamination is potentially introduced to water samples by exposure to airborne gases and particulates, from inadequate cleaning of sampling or analytic equipment, and from inadvertent sources during sample collection, field processing, shipment, and laboratory analysis. Potential contamination bias, based on frequency and magnitude of detections in field blanks, is used to determine whether or under what conditions environmental data might need to be qualified for the interpretation of results in the context of comparisons with background levels, drinking-water standards, aquatic-life criteria or benchmarks, or human-health benchmarks. Environmental samples for which contamination bias as determined in this report applies are those from historical U.S. Geological Survey water-quality networks or programs that were collected during the same time frame and according to the same protocols and that were analyzed in the same laboratory as field blanks described in this report.Results from field blanks for ammonia, nitrite, nitrite plus nitrate, orthophosphate, and total phosphorus were partitioned by analytical method; results from the most commonly used analytical method for total phosphorus were further partitioned by date. Depending on the analytical method, 3.8, 9.2, or 26.9 percent of environmental samples, the last of these percentages pertaining to all results from 2007 through 2012, were potentially affected by ammonia contamination. Nitrite contamination potentially affected up to 2.6 percent of environmental samples collected between 2002 and 2006 and affected about 3.3 percent of samples collected between 2007 and 2012. The percentages of environmental samples collected between 2002 and 2011 that were potentially affected by nitrite plus nitrate contamination were 7.3 for samples analyzed with the low-level method and 0.4 for samples analyzed with the standard-level method. These percentages increased to 14.8 and 2.2 for samples collected in 2012 and analyzed using replacement low- and standard-level methods, respectively. The maximum potentially affected concentrations for nitrite and for nitrite plus nitrate were much less than their respective maximum contamination levels for drinking-water standards. Although contamination from particulate nitrogen can potentially affect up to 21.2 percent and that from total Kjeldahl nitrogen can affect up to 16.5 percent of environmental samples, there are no critical or background levels for these substances.For total nitrogen, orthophosphate, and total phosphorus, contamination in a small percentage of environmental samples might be consequential for comparisons relative to impairment risks or background levels. At the low ends of the respective ranges of impairment risk for these nutrients, contamination in up to 5 percent of stream samples could account for at least 23 percent of measured concentrations of total nitrogen, for at least 40 or 90 percent of concentrations of orthophosphate, depending on the analytical method, and for 31 to 76 percent of concentrations of total phosphorus, depending on the time period.Twenty-six pesticides had no detections in field blanks. Atrazine with 12 and metolachlor with 11 had the highest number of detections, mostly occurring in spring or early summer. At a 99-percent level of confidence, contamination was estimated to be no greater than the detection limit in at least 98 percent of all samples for 38 of 40 pesticides. For metolachlor and atrazine, potential contamination was no greater than 0.0053 and 0.0093 micrograms per liter in 98 percent of samples. For 11 of 14 pesticides with at least one detection, the maximum potentially affected concentration of the environmental sample was less than their respective human-health or aquatic-life benchmarks. Small percentages of environmental samples had concentrations high enough that atrazine contamination potentially could account for the entire aquatic-life benchmark for acute effects on nonvascular plants, that dieldrin contamination could account for up to 100 percent of the cancer health-based screening level, or that chlorpyrifos contamination could account for 13 or 12 percent of the concentrations in the aquatic-life benchmarks for chronic effects on invertebrates or the criterion continuous concentration for chronic effects on aquatic life.

  10. EVALUATION OF THE FILTER PACK FOR LONG-DURATION SAMPLING OF AMBIENT AIR

    EPA Science Inventory

    A 14-week filter pack (FP) sampler evaluation field study was conducted at a site near Bondville, IL to investigate the impact of weekly sampling duration. Simultaneous samples were collected using collocated filter packs (FP) from two independent air quality monitoring networks...

  11. Colloidal-facilitated transport of inorganic contaminants in ground water: part 1, sampling considerations

    USGS Publications Warehouse

    Puls, Robert W.; Eychaner, James H.; Powell, Robert M.

    1996-01-01

    Investigations at Pinal Creek, Arizona, evaluated routine sampling procedures for determination of aqueous inorganic geochemistry and assessment of contaminant transport by colloidal mobility. Sampling variables included pump type and flow rate, collection under air or nitrogen, and filter pore diameter. During well purging and sample collection, suspended particle size and number as well as dissolved oxygen, temperature, specific conductance, pH, and redox potential were monitored. Laboratory analyses of both unfiltered samples and the filtrates were performed by inductively coupled argon plasma, atomic absorption with graphite furnace, and ion chromatography. Scanning electron microscopy with Energy Dispersive X-ray was also used for analysis of filter particulates. Suspended particle counts consistently required approximately twice as long as the other field-monitored indicators to stabilize. High-flow-rate pumps entrained normally nonmobile particles. Difference in elemental concentrations using different filter-pore sizes were generally not large with only two wells having differences greater than 10 percent in most wells. Similar differences (>10%) were observed for some wells when samples were collected under nitrogen rather than in air. Fe2+/Fe3+ ratios for air-collected samples were smaller than for samples collected under a nitrogen atmosphere, reflecting sampling-induced oxidation.

  12. FIELD TRAPPING OF SUBSURFACE VAPOR PHASE PETROLEUM HYDROCARBONS

    EPA Science Inventory

    Soil gas samples from intact soil cores were collected on adsorbents at a field site, then thermally desorbed and analyzed by laboratory gas chromatography (GC). ertical concentration profiles of predominant vapor phase petroleum hydrocarbons under ambient conditions were obtaine...

  13. A Portable, Field-Deployable Analyzer for Isotopic Water Measurements

    NASA Astrophysics Data System (ADS)

    Berman, E. S.; Gupta, M.; Huang, Y. W.; Lacelle, D.; McKay, C. P.; Fortson, S.

    2015-12-01

    Water stable isotopes have for many years been used to study the hydrological cycle, catchment hydrology, and polar climate among other applications. Typically, discrete water samples are collected and transported to a laboratory for isotope analysis. Due to the expense and labor associated with such sampling, isotope studies have generally been limited in scope and time-resolution. Field sampling of water isotopes has been shown in recent years to provide dense data sets with the increased time resolution illuminating substantially greater short term variability than is generally observed during discrete sampling. A truly portable instrument also opens the possibility to utilize the instrument as a tool for identifying which water samples would be particularly interesting for further laboratory investigation. To make possible such field measurements of liquid water isotopes, Los Gatos Research has developed a miniaturized, field-deployable liquid water isotope analyzer. The prototype miniature liquid water isotope analyzer (mini-LWIA) uses LGR's patented Off-Axis ICOS (Integrated Cavity Output Spectroscopy) technology in a rugged, Pelican case housing for easy transport and field operations. The analyzer simultaneously measures both δ2H and δ18O from liquid water, with both manual and automatic water introduction options. The laboratory precision for δ2H is 0.6 ‰, and for δ18O is 0.3 ‰. The mini-LWIA was deployed in the high Arctic during the summer of 2015 at Inuvik in the Canadian Northwest Territories. Samples were collected from Sachs Harbor, on the southwest coast of Banks Island, including buried basal ice from the Lurentide Ice Sheet, some ice wedges, and other types of ground ice. Methodology and water analysis results from this extreme field deployment will be presented.

  14. Comparison of Precision of Biomass Estimates in Regional Field Sample Surveys and Airborne LiDAR-Assisted Surveys in Hedmark County, Norway

    NASA Technical Reports Server (NTRS)

    Naesset, Erik; Gobakken, Terje; Bollandsas, Ole Martin; Gregoire, Timothy G.; Nelson, Ross; Stahl, Goeran

    2013-01-01

    Airborne scanning LiDAR (Light Detection and Ranging) has emerged as a promising tool to provide auxiliary data for sample surveys aiming at estimation of above-ground tree biomass (AGB), with potential applications in REDD forest monitoring. For larger geographical regions such as counties, states or nations, it is not feasible to collect airborne LiDAR data continuously ("wall-to-wall") over the entire area of interest. Two-stage cluster survey designs have therefore been demonstrated by which LiDAR data are collected along selected individual flight-lines treated as clusters and with ground plots sampled along these LiDAR swaths. Recently, analytical AGB estimators and associated variance estimators that quantify the sampling variability have been proposed. Empirical studies employing these estimators have shown a seemingly equal or even larger uncertainty of the AGB estimates obtained with extensive use of LiDAR data to support the estimation as compared to pure field-based estimates employing estimators appropriate under simple random sampling (SRS). However, comparison of uncertainty estimates under SRS and sophisticated two-stage designs is complicated by large differences in the designs and assumptions. In this study, probability-based principles to estimation and inference were followed. We assumed designs of a field sample and a LiDAR-assisted survey of Hedmark County (HC) (27,390 km2), Norway, considered to be more comparable than those assumed in previous studies. The field sample consisted of 659 systematically distributed National Forest Inventory (NFI) plots and the airborne scanning LiDAR data were collected along 53 parallel flight-lines flown over the NFI plots. We compared AGB estimates based on the field survey only assuming SRS against corresponding estimates assuming two-phase (double) sampling with LiDAR and employing model-assisted estimators. We also compared AGB estimates based on the field survey only assuming two-stage sampling (the NFI plots being grouped in clusters) against corresponding estimates assuming two-stage sampling with the LiDAR and employing model-assisted estimators. For each of the two comparisons, the standard errors of the AGB estimates were consistently lower for the LiDAR-assisted designs. The overall reduction of the standard errors in the LiDAR-assisted estimation was around 40-60% compared to the pure field survey. We conclude that the previously proposed two-stage model-assisted estimators are inappropriate for surveys with unequal lengths of the LiDAR flight-lines and new estimators are needed. Some options for design of LiDAR-assisted sample surveys under REDD are also discussed, which capitalize on the flexibility offered when the field survey is designed as an integrated part of the overall survey design as opposed to previous LiDAR-assisted sample surveys in the boreal and temperate zones which have been restricted by the current design of an existing NFI.

  15. The Organization of a Computer Software Collection Using an Information Storage and Retrieval Software Package.

    ERIC Educational Resources Information Center

    Davies, Denise M.

    1985-01-01

    Discusses design, development, and use of a database to provide organization and access to a computer software collection at the University of Hawaii School of Library Studies. Field specifications, samples of report forms, and a description of the physical organization of the software collection are included. (MBR)

  16. Field Degassing as a New Sampling Method for 14C Analyses in Old Groundwater

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yokochi, Reika; Bernier, Ryan; Purtschert, Roland

    Radiocarbon ( 14C) activity in groundwater can be used to determine subsurface residence time up to ~40 kyr, providing crucial information on dynamic properties of groundwater and on paleoclimate. However, commonly applied sampling methods for dissolved inorganic carbon (DIC- 14C) are prone to low level of modern atmospheric contamination, resulting in underestimation of groundwater ages that cluster around 30–40 kyr. We extract CO 2 gas from groundwater using a device originally developed for studies of noble gas radionuclides. Carbon is collected in the gas phase, eliminating the possibility of fostering microbial activities and aqueous chemical reactions during sample storage. Thismore » method collects CO 2- 14C and radiokrypton ( 81Kr and 85Kr) samples simultaneously. The presence of any shorter-lived 85Kr is used to evaluate the degree of atmospheric contamination during sampling or mixing of young groundwater. Most groundwater samples showed lower CO 2- 14C activities than those of DIC- 14C, presumably due to the absence of atmospheric contamination. Samples with 81Kr age exceeding 150 kyr have no detectable CO 2- 14C except where mixing sources of young groundwater is suspected. Furthermore these field data serve as confirmations for the reliability of the newly presented sample collection and CO 2- 14C method, and for the outstanding roles of radiokrypton isotopes in characterizing old groundwater.« less

  17. Field Degassing as a New Sampling Method for 14C Analyses in Old Groundwater

    DOE PAGES

    Yokochi, Reika; Bernier, Ryan; Purtschert, Roland; ...

    2017-09-07

    Radiocarbon ( 14C) activity in groundwater can be used to determine subsurface residence time up to ~40 kyr, providing crucial information on dynamic properties of groundwater and on paleoclimate. However, commonly applied sampling methods for dissolved inorganic carbon (DIC- 14C) are prone to low level of modern atmospheric contamination, resulting in underestimation of groundwater ages that cluster around 30–40 kyr. We extract CO 2 gas from groundwater using a device originally developed for studies of noble gas radionuclides. Carbon is collected in the gas phase, eliminating the possibility of fostering microbial activities and aqueous chemical reactions during sample storage. Thismore » method collects CO 2- 14C and radiokrypton ( 81Kr and 85Kr) samples simultaneously. The presence of any shorter-lived 85Kr is used to evaluate the degree of atmospheric contamination during sampling or mixing of young groundwater. Most groundwater samples showed lower CO 2- 14C activities than those of DIC- 14C, presumably due to the absence of atmospheric contamination. Samples with 81Kr age exceeding 150 kyr have no detectable CO 2- 14C except where mixing sources of young groundwater is suspected. Furthermore these field data serve as confirmations for the reliability of the newly presented sample collection and CO 2- 14C method, and for the outstanding roles of radiokrypton isotopes in characterizing old groundwater.« less

  18. Field comparison of analytical results from discrete-depth ground water samplers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zemo, D.A.; Delfino, T.A.; Gallinatti, J.D.

    1995-07-01

    Discrete-depth ground water samplers are used during environmental screening investigations to collect ground water samples in lieu of installing and sampling monitoring wells. Two of the most commonly used samplers are the BAT Enviroprobe and the QED HydroPunch I, which rely on differing sample collection mechanics. Although these devices have been on the market for several years, it was unknown what, if any, effect the differences would have on analytical results for ground water samples containing low to moderate concentrations of chlorinated volatile organic compounds (VOCs). This study investigated whether the discrete-depth ground water sampler used introduces statistically significant differencesmore » in analytical results. The goal was to provide a technical basis for allowing the two devices to be used interchangeably during screening investigations. Because this study was based on field samples, it included several sources of potential variability. It was necessary to separate differences due to sampler type from variability due to sampling location, sample handling, and laboratory analytical error. To statistically evaluate these sources of variability, the experiment was arranged in a nested design. Sixteen ground water samples were collected from eight random locations within a 15-foot by 15-foot grid. The grid was located in an area where shallow ground water was believed to be uniformly affected by VOCs. The data were evaluated using analysis of variance.« less

  19. A mineral reconnaissance sampling manual for Costa Rica: Central American energy and resoure project. Manual para muestreo en el reconocimiento mineral de Costa Rica: Proyecto Centroamericano de energia y recursos naturales (in English and Spanish)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bolivar, S.

    This manual describes field procedures for the collection of stream-sediment and rock samples as part of the Mineral Resource Assessment of Costa Rica. It provides guidelines to be followed by personnel collecting, treating, or otherwise handling samples taken as part of this program. The objectives of the manual are to ensure that all samples are collected uniformly and consistent techniques are employed throughout the program. If this is done, the data from this study can be used to identify areas with potential for mineralization. This manual can also be used as a guideline for future geochemical sampling programs in Costamore » Rica.« less

  20. Assessment of the influence of field size on maize gene flow using SSR analysis.

    PubMed

    Palaudelmàs, M; Melé, E; Monfort, A; Serra, J; Salvia, J; Messeguer, J

    2012-06-01

    One of the factors that may influence the rate of cross-fertilization is the relative size of the pollen donor and receptor fields. We designed a spatial distribution with four varieties of genetically-modified (GM) yellow maize to generate different sized fields while maintaining a constant distance to neighbouring fields of conventional white kernel maize. Samples of cross-fertilized, yellow kernels in white cobs were collected from all of the adjacent fields at different distances. A special series of samples was collected at distances of 0, 2, 5, 10, 20, 40, 80 and 120 m following a transect traced in the dominant down-wind direction in order to identify the origin of the pollen through SSR analysis. The size of the receptor fields should be taken into account, especially when they extend in the same direction than the GM pollen flow is coming. From collected data, we then validated a function that takes into account the gene flow found in the field border and that is very useful for estimating the % of GM that can be found in any point of the field. It also serves to predict the total GM content of the field due to cross fertilization. Using SSR analysis to identify the origin of pollen showed that while changes in the size of the donor field clearly influence the percentage of GMO detected, this effect is moderate. This study demonstrates that doubling the donor field size resulted in an approximate increase of GM content in the receptor field of 7%. This indicates that variations in the size of the donor field have a smaller influence on GM content than variations in the size of the receptor field.

  1. Willie takes a field trip; coloring book

    USGS Publications Warehouse

    Arvin, Donald V.

    1990-01-01

    This coloring book is an educational tool designed to instruct children on some of the field activities commonly associated with the collection of water resource data. Through the use of line drawings and brief descriptive text, young readers will follow little Willie and his Uncle Bill as they spend a pleasant day in the field measuring streamflow, collecting sediment samples, making groundwater measurements at observation wells, and measuring flow in a pipe. Although this 37-page coloring book is geared to children 5 to 10 years old, people of all ages may find it enjoyable.

  2. Results of quality-control sampling of water, bed sediment, and tissue in the Western Lake Michigan Drainages study unit of the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Fitzgerald, S.A.

    1997-01-01

    This report contains the quality control results of the Western Lake Michigan Drainages study unit of the National Water Quality Assessment Program. Quality control samples were collected in the same manner and contemporaneously with environmental samples during the first highintensity study phase in the unit (1992 through 1995) and amounted to approximately 15 percent of all samples collected. The accuracy and precision of hundreds of chemical analyses of surface and ground-water, bed sediment, and tissue was determined through the collection and analysis of field blanks, field replicates and splits, matrix spikes, and surrogates. Despite the several detections of analytes in the field blanks, the concentrations of most constituents in the environmental samples will likely be an order of magnitude or higher than those in the blanks. However, frequent detections, and high concentrations, of dissolved organic carbon (DOC) in several surface and ground-water blanks are probably significant with respect to commonly measured environmental concentrations, and the environmental data will have to be qualified accordingly. The precision of sampling of water on a percent basis, as determined from replicates and splits, was generally proportional to the concentration of the constituents, with constituents present in relatively high concentrations generally having less sampling variability than those with relatively low concentrations. In general, analytes with relatively high variability between replicates were present at concentrations near the reporting limit or were associated with relatively small absolute concentration differences, or both. Precision of replicates compared to that for splits in bed sediment samples was similar, thus eliminating sampling as a major source of variability in analyte concentrations. In the case the phthalates in bed sediment, contamination in either the field or laboratory could have caused the relatively large variability between replicate samples and between split samples.Variability of analyte concentrations in tissue samples was relatively low, being 29 percent or less for all constituents. Recoveries of most laboratory schedule 2001/2010 pesticide spike compounds in surfacewater samples were reasonably good. Low intrinsic method recovery resulted in relatively low recovery forp,p'-DDE, metribuzin, and propargite. In the case of propargite, decomposition with the environmental sample matrices was also indicated. Recoveries of two compounds, cyanazine and thiobencarb, might have been biased high due to interferences. The one laboratory schedule 2050/2051 field matrix pesticide spike indicated numerous operational problems with this method that biased recoveries either low or high. Recoveries of pesticides from both pesticide schedules in field spikes of ground-water samples generally were similar to those of field matrix spikes of surface- water samples. High maximum recoveries were noted for tebuthiuron, disulfoton, DCPA, and permethrin, which indicates the possible presence of interferents in the matrices for these compounds. Problems in the recoveries of pesticides on schedule 2050/2051 from ground-water samples generally were the same as those for surfacewater samples. Recoveries of VOCs in field matrix spikes were reasonable when consideration was given for the use of the micropipettor that delivered only about 80 percent on average of the nominal mass of spiked analytes. Finally, the recoveries of most surrogate compounds in surface and ground-water samples were reasonable. Problems in sample handling (for example, spillage) were likely not the cause of any of the low recoveries of spiked compounds.

  3. Use of FTA sampling cards for molecular detection of avian influenza virus in wild birds.

    PubMed

    Keeler, Shamus P; Ferro, Pamela J; Brown, Justin D; Fang, Xingwang; El-Attrache, John; Poulson, Rebecca; Jackwood, Mark W; Stallknecht, David E

    2012-03-01

    Current avian influenza (AI) virus surveillance programs involving wild birds rely on sample collection methods that require refrigeration or low temperature freezing to maintain sample integrity for virus isolation and/or reverse-transcriptase (RT) PCR. Maintaining the cold chain is critical for the success of these diagnostic assays but is not always possible under field conditions. The aim of this study was to test the utility of Finders Technology Associates (FTA) cards for reliable detection of AI virus from cloacal and oropharyngeal swabs of wild birds. The minimum detectable titer was determined, and the effect of room temperature storage was evaluated experimentally using multiple egg-propagated stock viruses (n = 6). Using real time RT-PCR, we compared results from paired cloacal swab and samples collected on FTA cards from both experimentally infected mallards (Anasplatyrhynchos) and hunter-harvested waterfowl sampled along the Texas Gulf Coast. Based on the laboratory trials, the average minimal detectable viral titer was determined to be 1 x 10(4.7) median embryo infectious dose (EID50)/ml (range: 1 x 10(4.3) to 1 x 10(5.4) EID50/ml), and viral RNA was consistently detectable on the FTA cards for a minimum of 20 days and up to 30 days for most subtypes at room temperature (23 C) storage. Real-time RT-PCR of samples collected using the FTA cards showed fair to good agreement in live birds when compared with both real-time RT-PCR and virus isolation of swabs. AI virus detection rates in samples from several wild bird species were higher when samples were collected using the FTA cards compared with cloacal swabs. These results suggest that FTA cards can be used as an alternative sample collection method when traditional surveillance methods are not possible, especially in avian populations that have historically received limited testing or situations in which field conditions limit the ability to properly store or ship swab samples.

  4. Evaluation of FTA cards as a laboratory and field sampling device for the detection of foot-and-mouth disease virus and serotyping by RT-PCR and real-time RT-PCR.

    PubMed

    Muthukrishnan, Madhanmohan; Singanallur, Nagendrakumar B; Ralla, Kumar; Villuppanoor, Srinivasan A

    2008-08-01

    Foot-and-mouth disease virus (FMDV) samples transported to the laboratory from far and inaccessible areas for serodiagnosis pose a major problem in a tropical country like India, where there is maximum temperature fluctuation. Inadequate storage methods lead to spoilage of FMDV samples collected from clinically positive animals in the field. Such samples are declared as non-typeable by the typing laboratories with the consequent loss of valuable epidemiological data. The present study evaluated the usefulness of FTA Classic Cards for the collection, shipment, storage and identification of the FMDV genome by RT-PCR and real-time RT-PCR. The stability of the viral RNA, the absence of infectivity and ease of processing the sample for molecular methods make the FTA cards a useful option for transport of FMDV genome for identification and serotyping. The method can be used routinely for FMDV research as it is economical and the cards can be transported easily in envelopes by regular document transport methods. Live virus cannot be isolated from samples collected in FTA cards, which is a limitation. This property can be viewed as an advantage as it limits the risk of transmission of live virus.

  5. Hydrogeochemical and stream sediment reconnaissance basic data for Roswell quadrangle, New Mexico

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    Field and laboratory data are presented for 842 water samples and 1270 sediment samples from the Roswell Quadrangle, New Mexico. The samples were collected by Los Alamos National Laboratory; laboratory analysis and data reporting were performed by the Uranium Resource Evaluation Project at Oak Ridge, Tennessee.

  6. Soil Sampling Techniques For Alabama Grain Fields

    NASA Technical Reports Server (NTRS)

    Thompson, A. N.; Shaw, J. N.; Mask, P. L.; Touchton, J. T.; Rickman, D.

    2003-01-01

    Characterizing the spatial variability of nutrients facilitates precision soil sampling. Questions exist regarding the best technique for directed soil sampling based on a priori knowledge of soil and crop patterns. The objective of this study was to evaluate zone delineation techniques for Alabama grain fields to determine which method best minimized the soil test variability. Site one (25.8 ha) and site three (20.0 ha) were located in the Tennessee Valley region, and site two (24.2 ha) was located in the Coastal Plain region of Alabama. Tennessee Valley soils ranged from well drained Rhodic and Typic Paleudults to somewhat poorly drained Aquic Paleudults and Fluventic Dystrudepts. Coastal Plain s o i l s ranged from coarse-loamy Rhodic Kandiudults to loamy Arenic Kandiudults. Soils were sampled by grid soil sampling methods (grid sizes of 0.40 ha and 1 ha) consisting of: 1) twenty composited cores collected randomly throughout each grid (grid-cell sampling) and, 2) six composited cores collected randomly from a -3x3 m area at the center of each grid (grid-point sampling). Zones were established from 1) an Order 1 Soil Survey, 2) corn (Zea mays L.) yield maps, and 3) airborne remote sensing images. All soil properties were moderately to strongly spatially dependent as per semivariogram analyses. Differences in grid-point and grid-cell soil test values suggested grid-point sampling does not accurately represent grid values. Zones created by soil survey, yield data, and remote sensing images displayed lower coefficient of variations (8CV) for soil test values than overall field values, suggesting these techniques group soil test variability. However, few differences were observed between the three zone delineation techniques. Results suggest directed sampling using zone delineation techniques outlined in this paper would result in more efficient soil sampling for these Alabama grain fields.

  7. Chemical constituents in clouds and rainwater in the Puerto Rican rainforest: potential sources and seasonal drivers

    Treesearch

    A. Gioda; O.L. Mayol-Bracero; F. N. Scatena; K. C. Weathers; V. L. Mateus; W. H. McDowell

    2013-01-01

    Cloud- and rain-water samples collected between 1984 and 2007 in the Luquillo Experimental Forest, Puerto Rico, were analyzed in order to understand the main processes and sources that control their chemistry. Three sites were used: El Verde Field Station (380 m asl), Bisley (361 m asl), and East Peak (1051 m asl). Bulk rainwater samples were collected from all sites,...

  8. Magnetic properties of a new obsidian source, west Antelope Creek, Grant County, New Mexico

    NASA Astrophysics Data System (ADS)

    Sternberg, R. S.; Samuels, R.; Feinberg, J. M.; Shackley, M. S.

    2013-12-01

    This work is part of a Keck Geology Consortium project on characterizing obsidian sources in New Mexico using magnetic and geochemical properties. We collected over 3,000 samples, many of which were georeferenced, from 10 obsidian sources at three locales - Mule creek, Mt. Taylor, and Valles Caldera. One of the Mule Creek sources, herein called the west Antelope Creek (wAC) source, was previously unknown. The 143 samples collected at this source covered about 1 km2, but were not individually georeferenced. We plan to characterize the magnetic and chemical properties of this source to see if it is distinguishable from other nearby sources and useful for provenancing archaeological obsidians. Initial measurements on 34 specimens from 20 samples show NRM values range from 1-80 Am2/kg, and low-field susceptibilities range from 1.2-96 x 10-8 mass specific SI units. When there were two specimens from the same sample, results were in good agreement. The measurements define a rather broad field in NRM-susceptibility space compared to other Southwestern sources examined to date, and a considerably larger field than from the nearby Antelope Creek (AC) source. The previously measured NRM and susceptibility values from AC are all in the high end on both dimensions of the wAC field, so that these fields overlap but in many cases could be distinguished.

  9. Occurrence of severe gastroenteritis in pups after canine parvovirus vaccine administration: a clinical and laboratory diagnostic dilemma.

    PubMed

    Decaro, Nicola; Desario, Costantina; Elia, Gabriella; Campolo, Marco; Lorusso, Alessio; Mari, Viviana; Martella, Vito; Buonavoglia, Canio

    2007-01-26

    A total of 29 faecal samples collected from dogs with diarrhoea following canine parvovirus (CPV) vaccination were tested by minor groove binder (MGB) probe assays for discrimination between CPV vaccine and field strains and by diagnostic tests for detection of other canine pathogens. Fifteen samples tested positive only for CPV field strains; however, both vaccine and field strains were detected in three samples. Eleven samples were found to contain only the vaccine strain, although eight of them tested positive for other pathogens of dogs. Only three samples were found to contain the vaccine strain without evidence of canine pathogens. The present study confirms that most cases of parvovirus-like disease occurring shortly after vaccination are related to infection with field strains of canine parvovirus type 2 (CPV-2) rather than to reversion to virulence of the modified live virus contained in the vaccine.

  10. Benthos and plankton community data for selected rivers and harbors along the western Lake Michigan shoreline, 2014

    USGS Publications Warehouse

    Scudder Eikenberry, Barbara C.; Burns, Daniel J.; Olds, Hayley T.; Bell, Amanda H.; Mapel, Kassidy T.

    2016-06-15

    Benthos (benthic invertebrates) and plankton (zooplankton and phytoplankton) communities were sampled in 2014 at 10 Wisconsin rivers and harbors, including 4 sites in Great Lakes Areas of Concern and 6 less degraded comparison sites with similar physical and chemical characteristics, including climate, latitude, geology, and land use. Previous U.S. Geological Survey sampling was completed in 2012, but because of ongoing sediment remediation at three of the Areas of Concern (AOCs) and unusually hot and dry conditions in many areas during 2012, additional sampling was added in 2014. Comparable sampling methods were used in 2012 and 2014. Benthos were collected by using Hester-Dendy artificial substrate samplers and composite Ponar grab samples of bottom sediment; zooplankton were collected by using tows from depth to the surface with a 63-micrometer mesh plankton net; phytoplankton were collected by using whole water samples composited from set depth intervals. This report describes the study areas and field sampling methods for 2014, and it presents data on taxonomic identification and abundance of benthos and plankton that can serve as a basis for evaluation of related Beneficial Use Impairments (BUIs) at the AOCs. Physical and chemical data were sampled concurrently (specific conductance, temperature, pH, dissolved oxygen, chlorophyll a, total and volatile suspended solids in water samples; particle size and volatile-on-ignition of sediment in benthic grab samples). The results of field quality assurance-quality control are also presented.

  11. Chemical and radiochemical constituents in water from wells in the vicinity of the naval reactors facility, Idaho National Engineering and Environmental Laboratory, Idaho, 1997-98

    USGS Publications Warehouse

    Bartholomay, Roy C.; Knobel, LeRoy L.; Tucker, Betty J.; Twining, Brian V.

    2000-01-01

    The U.S. Geological Survey, in response to a request from the U.S. Department of Energy?s Phtsburgh Naval Reactors Ofilce, Idaho Branch Office, sampled water from 13 wells during 1997?98 as part of a long-term project to monitor water quality of the Snake River Plain aquifer in the vicinity of the Naval Reactors Facility, Idaho National Engineering and Environmental Laboratory, Idaho. Water samples were analyzed for naturally occurring constituents and man-made contaminants. A totalof91 samples were collected from the 13 monitoring wells. The routine samples contained detectable concentrations of total cations and dissolved anions, and nitrite plus nitrate as nitrogen. Most of the samples also had detectable concentrations of gross alpha- and gross beta-particle radioactivity and tritium. Fourteen qualityassurance samples also were collected and analyze~ seven were field-blank samples, and seven were replicate samples. Most of the field blank samples contained less than detectable concentrations of target constituents; however, some blank samples did contain detectable concentrations of calcium, magnesium, barium, copper, manganese, nickel, zinc, nitrite plus nitrate, total organic halogens, tritium, and selected volatile organic compounds.

  12. Design and validation of a passive deposition sampler.

    PubMed

    Einstein, Stephanie A; Yu, Chang-Ho; Mainelis, Gediminas; Chen, Lung Chi; Weisel, Clifford P; Lioy, Paul J

    2012-09-01

    A new, passive particle deposition air sampler, called the Einstein-Lioy Deposition Sampler (ELDS), has been developed to fill a gap in passive sampling for near-field particle emissions. The sampler can be configured in several ways: with a protective hood for outdoor sampling, without a protective hood, and as a dust plate. In addition, there is an XRF-ready option that allows for direct sampling onto a filter-mounted XRF cartridge which can be used in conjunction with all configurations. A wind tunnel was designed and constructed to test the performance of different sampler configurations using a test dust with a known particle size distribution. The sampler configurations were also tested versus each other to evaluate whether or not the protective hood would affect the collected particle size distribution. A field study was conducted to test the sampler under actual environmental conditions and to evaluate its ability to collect samples for chemical analysis. Individual experiments for each configuration demonstrated precision of the sampler. The field experiment demonstrated the ability of the sampler to both collect mass and allow for the measurement of an environmental contaminant i.e. Cr(6+). The ELDS was demonstrated to be statistically not different for Hooded and Non-Hooded models, compared to each other and the test dust; thus, it can be used indoors and outdoors in a variety of configurations to suit the user's needs.

  13. The case of biobank with the law: between a legal and scientific fiction.

    PubMed

    Sándor, Judit; Bárd, Petra; Tamburrini, Claudio; Tännsjö, Torbjörn

    2012-06-01

    According to estimates more than 400 biobanks currently operate across Europe. The term 'biobank' indicates a specific field of genetic study that has quietly developed without any significant critical reflection across European societies. Although scientists now routinely use this phrase, the wider public is still confused when the word 'bank' is being connected with the collection of their biological samples. There is a striking lack of knowledge of this field. In the recent Eurobarometer survey it was demonstrated that even in 2010 two-thirds of the respondents had never even heard about biobanks. The term gives the impression that a systematic collection of biological samples can constitute a 'bank' of considerable financial worth, where the biological samples, which are insignificant in isolation but are valuable as a collection, can be preserved, analysed and put to 'profitable use'. By studying the practices of the numerous already existing biobanks, the authors address the following questions: to what extent does the term 'biobank' reflect the normative concept of using biological samples for the purposes of biomedical research? Furthermore, is it in harmony with the so far agreed legal-ethical consensus in Europe or does it deliberately pull science to the territory of a new, ambiguous commercial field? In other words, do biobanks constitute a medico-legal fiction or are they substantively different from other biomedical research protocols on human tissues?

  14. A Coastal Environment Field and Laboratory Activity for an Undergraduate Geomorphology Course

    ERIC Educational Resources Information Center

    Ellis, Jean T.; Rindfleisch, Paul R.

    2006-01-01

    A field and laboratory exercise for an undergraduate geomorphology class is described that focuses on the beach. The project requires one day of fieldwork and two laboratory sessions. In the field, students measure water surface fluctuations (waves) with a pressure sensor, survey beach profiles, collect sediment samples, and observe the beach…

  15. Concentrations, Distribution and Persistence of Fluorotelomer Alcohols in Sludge-Applied Soils near Decatur, Alabama, USA

    EPA Science Inventory

    Soil samples were collected for fluorotelomer alcohol (FTOH) analyses from six fields to which sludge had been applied and one “background” field that had not received sludge. Ten analytes in soil extracts were quantified using GC/MS. Sludge-applied fields had surface soil FTOH c...

  16. Water-quality data for the Russian River Basin, Mendocino and Sonoma Counties, California, 2005-2010

    USGS Publications Warehouse

    Anders, Robert; Davidek, Karl; Stoeckel, Donald M.

    2011-01-01

    Field measurements included discharge, barometric pressure, dissolved oxygen, pH, specific conductance, temperature, and turbidity. All samples were analyzed for nutrients, major ions, trace metals, total and dissolved organic carbon, organic wastewater compounds, standard bacterial indicators, and the stable isotopes of hydrogen and oxygen. Standard bacterial indicators included total coliform, Escherichia coli, enterococci, and Clostridium perfringens for the period 2005 through 2007, and total and fecal coliform, and enterococci for 2010. In addition, enrichment of enterococci was performed on all surface-water samples collected during summer 2006, for detection of the human-associated enterococcal surface protein in Enterococcus faecium to assess the presence of sewage effluent in the Russian River. Other analyses included organic wastewater compounds of bed sediment samples collected from four Russian River sites during 2005; carbon-13 isotopic values of the dissolved inorganic carbon for surface-water and groundwater samples collected during 2006; human-use pharmaceuticals on Russian River samples collected during 2007 and 2010; and the radiogenic isotopes tritium and carbon-14 for groundwater samples collected during 2008.

  17. Azole-resistant Aspergillus fumigatus harboring TR34/L98H, TR46/Y121F/T289A and TR53 mutations related to flower fields in Colombia

    NASA Astrophysics Data System (ADS)

    Alvarez-Moreno, Carlos; Lavergne, Rose-Anne; Hagen, Ferry; Morio, Florent; Meis, Jacques F.; Le Pape, Patrice

    2017-03-01

    Resistance to triazoles in Aspergillus fumigatus has been reported in azole-naive patients in Europe, Asia, Australia and North America. This resistance has been linked to fungicide-driven mutations in the cyp51A gene and its promoter region. We investigated the presence of environmental azole-resistant A. fumigatus strains related to the use of azole fungicides in Colombia. Soil samples were collected from flower beds, flower fields and public gardens from the outskirts, suburbs and city centre of Bogotá. Out of the 86 soil samples taken, 17 (19.8%) grew A. fumigatus of whom eight (9.3%) contained 40 strains able to grow on azole-containing itraconazole and/or voriconazole supplemented media. All but one triazole-resistant strains were isolated from soil samples collected from flower fields and flower beds (39/40). Importantly, the majority had the TR46/Y121F/T289A, TR34/L98H, and TR53 molecular resistance mechanisms and one azole resistant strain had a wild-type cyp51A gene. Soil samples from flower fields and beds contained 4 azole fungicides (penconazole, difenoconazole, tetraconazole and tebuconazole) above the limit of detection. Our findings underline the need for extensive investigations to determine azole-resistant A. fumigatus prevalence in both clinical and environmental samples in other regions of Latin America.

  18. Azole-resistant Aspergillus fumigatus harboring TR34/L98H, TR46/Y121F/T289A and TR53 mutations related to flower fields in Colombia.

    PubMed

    Alvarez-Moreno, Carlos; Lavergne, Rose-Anne; Hagen, Ferry; Morio, Florent; Meis, Jacques F; Le Pape, Patrice

    2017-03-30

    Resistance to triazoles in Aspergillus fumigatus has been reported in azole-naive patients in Europe, Asia, Australia and North America. This resistance has been linked to fungicide-driven mutations in the cyp51A gene and its promoter region. We investigated the presence of environmental azole-resistant A. fumigatus strains related to the use of azole fungicides in Colombia. Soil samples were collected from flower beds, flower fields and public gardens from the outskirts, suburbs and city centre of Bogotá. Out of the 86 soil samples taken, 17 (19.8%) grew A. fumigatus of whom eight (9.3%) contained 40 strains able to grow on azole-containing itraconazole and/or voriconazole supplemented media. All but one triazole-resistant strains were isolated from soil samples collected from flower fields and flower beds (39/40). Importantly, the majority had the TR 46 /Y121F/T289A, TR 34 /L98H, and TR 53 molecular resistance mechanisms and one azole resistant strain had a wild-type cyp51A gene. Soil samples from flower fields and beds contained 4 azole fungicides (penconazole, difenoconazole, tetraconazole and tebuconazole) above the limit of detection. Our findings underline the need for extensive investigations to determine azole-resistant A. fumigatus prevalence in both clinical and environmental samples in other regions of Latin America.

  19. Draft Genome Sequences of Two Janthinobacteriumlividum Strains, Isolated from Pristine Groundwater Collected from the Oak Ridge Field Research Center.

    PubMed

    Wu, Xiaoqin; Deutschbauer, Adam M; Kazakov, Alexey E; Wetmore, Kelly M; Cwick, Bryson A; Walker, Robert M; Novichkov, Pavel S; Arkin, Adam P; Chakraborty, Romy

    2017-06-29

    We present here the draft genome sequences of two Janthinobacterium lividum strains, GW456P and GW458P, isolated from groundwater samples collected from a background site at the Oak Ridge Field Research Center. Production of a purple pigment by these two strains was observed when grown on diluted (1/10) LB agar plates. Copyright © 2017 Wu et al.

  20. Portable Automation of Static Chamber Sample Collection for Quantifying Soil Gas Flux

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, Morgan P.; Groh, Tyler A.; Parkin, Timothy B.

    Quantification of soil gas flux using the static chamber method is labor intensive. The number of chambers that can be sampled is limited by the spacing between chambers and the availability of trained research technicians. An automated system for collecting gas samples from chambers in the field would eliminate the need for personnel to return to the chamber during a flux measurement period and would allow a single technician to sample multiple chambers simultaneously. This study describes Chamber Automated Sampling Equipment (FluxCASE) to collect and store chamber headspace gas samples at assigned time points for the measurement of soil gasmore » flux. The FluxCASE design and operation is described, and the accuracy and precision of the FluxCASE system is evaluated. In laboratory measurements of nitrous oxide (N2O), carbon dioxide (CO2), and methane (CH4) concentrations of a standardized gas mixture, coefficients of variation associated with automated and manual sample collection were comparable, indicating no loss of precision. In the field, soil gas fluxes measured from FluxCASEs were in agreement with manual sampling for both N2O and CO2. Slopes of regression equations were 1.01 for CO2 and 0.97 for N2O. The 95% confidence limits of the slopes of the regression lines included the value of one, indicating no bias. Additionally, an expense analysis found a cost recovery ranging from 0.6 to 2.2 yr. Implementing the FluxCASE system is an alternative to improve the efficiency of the static chamber method for measuring soil gas flux while maintaining the accuracy and precision of manual sampling.« less

  1. An innovative tool for moving malaria PCR detection of parasite reservoir into the field

    PubMed Central

    2013-01-01

    Background To achieve the goal of malaria elimination in low transmission areas such as in Cambodia, new, inexpensive, high-throughput diagnostic tools for identifying very low parasite densities in asymptomatic carriers are required. This will enable a switch from passive to active malaria case detection in the field. Methods DNA extraction and real-time PCR assays were implemented in an “in-house” designed mobile laboratory allowing implementation of a robust, sensitive and rapid malaria diagnostic strategy in the field. This tool was employed in a survey organized in the context of the MalaResT project (NCT01663831). Results The real-time PCR screening and species identification assays were performed in the mobile laboratory between October and November 2012, in Rattanakiri Province, to screen approximately 5,000 individuals in less than four weeks and treat parasite carriers within 24–48 hours after sample collection. An average of 240 clinical samples (and 40 quality control samples) was tested every day, six/seven days per week. Some 97.7% of the results were available <24 hours after the collection. A total of 4.9% were positive for malaria. Plasmodium vivax was present in 61.1% of the positive samples, Plasmodium falciparum in 45.9%, Plasmodium malariae in 7.0% and Plasmodium ovale in 2.0%. Conclusions The operational success of this diagnostic set-up proved that molecular testing and subsequent treatment is logistically achievable in field settings. This will allow the detection of clusters of asymptomatic carriers and to provide useful epidemiological information. Fast results will be of great help for staff in the field to track and treat asymptomatic parasitaemic cases. The concept of the mobile laboratory could be extended to other countries for the molecular detection of malaria or other pathogens, or to culture vivax parasites, which does not support long-time delay between sample collection and culture. PMID:24206649

  2. Rare Earth Element Concentrations in Geothermal Wells at the Puna Geothermal Field, Hawaii

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fowler, Andrew; Zierenberg, Robert

    Rare earth element concentrations in the geothermal wells at the Puna geothermal field, Hawaii. Samples taken from geothermal wells KS-5, KS-6W, KS-9W, KS-14E, and KS-16N. Includes pH and concentrations for Cerium, Dysprosium, Erbium, Europium, Gadolinium, Holmium, Lanthanum, Lutetium, Neodymium, Praseodymium, Samarium, Terbium, Thulium, Yttrium, and Ytterbium. Samples collected on November 11-17, 2016.

  3. Comparing Apollo and Mars Exploration Rover (MER) Operations Paradigms for Human Exploration During NASA Desert-Rats Science Operations

    NASA Technical Reports Server (NTRS)

    Yingst, R. A.; Cohen, B. A.; Ming, D. W.; Eppler, D. B.

    2011-01-01

    NASA's Desert Research and Technology Studies (D-RATS) field test is one of several analog tests that NASA conducts each year to combine operations development, technology advances and science under planetary surface conditions. The D-RATS focus is testing preliminary operational concepts for extravehicular activity (EVA) systems in the field using simulated surface operations and EVA hardware and procedures. For 2010 hardware included the Space Exploration Vehicles, Habitat Demonstration Units, Tri-ATHLETE, and a suite of new geology sample collection tools, including a self-contained GeoLab glove box for conducting in-field analysis of various collected rock samples. The D-RATS activities develop technical skills and experience for the mission planners, engineers, scientists, technicians, and astronauts responsible for realizing the goals of exploring planetary surfaces.

  4. Water-quality, biological, and habitat assessment of the Boeuf River Basin, southeastern Arkansas, 1994-96

    USGS Publications Warehouse

    Barks, C. Shane; Petersen, James C.; Usrey, Faron D.

    2002-01-01

    Water-quality and biological samples were collected at several sites in the Boeuf River Basin between November 1994 and December 1996. Water-quality and benthic macroinvertebrate community samples were collected and habitat was measured once at 25 ambient monitoring sites during periods of seasonal low flow. Water-quality storm-runoff samples were collected during 11 storm events at two sites (one draining a cotton field and one draining a forested area). Water-quality samples were collected at one site during the draining of a catfish pond. Water-quality samples from the 25 ambient sites indicate that streams in the Boeuf River Basin typically are turbid and nutrient enriched in late fall during periods of relatively low flow. Most suspended solids concentrations ranged from about 50 to 200 milligrams per liter (mg/L), most total nitrogen concentrations ranged from about 1.1 to 1.8 mg/L, and most total phosphorus concentrations ranged from about 0.25 to 0.40 mg/L. Suspended solids, total nitrogen, total ammonia plus organic nitrogen, total phosphorus, and dissolved orthophosphorus concentrations from samples collected during storm events were typically higher at the cotton field site than at the forested site. Estimated annual yields of suspended solids, nitrogen, and phosphorus were substantially higher from the cotton field than from the forested area. Dissolved chloride concentrations typically were higher at the forested site than from the cotton field site. Typically, the suspended solids and nutrient concentrations from the 25 ambient sites were lower than concentrations in runoff from the cotton field but higher than concentrations in runoff from the forest area. Concentrations of sulfate, chloride, suspended solids, and some nutrients in samples from the catfish pond generally were greater than concentrations in samples from other sites. Total phosphorus, orthophosphorus, and fecal coliform bacteria concentrations from the catfish pond generally were lower than concentrations in samples from other sites. Biological condition scores calculated using macroinvertebrate samples and U.S. Environmental Protection Agency Rapid Bioassessment Protocol II indicated that most of the 25 ambient sites would be in the 'moderately impaired' category. However, substantial uncertainty exists in this rating because bioassessment data were compared with data from a reference site outside of the Boeuf River Basin sampled using different methods. Several metrics indicated that communities at most of the ambient sites are composed of more tolerant macroinvertebrates than the community at the reference site. Habitat assessments (using Rapid Bioassessment Protocol II) indicated the reference site outside the Boeuf River Basin had better habitat than the ambient sites. Physical habitat scores for the 25 ambient sites indicated that most ambient sites had poor bottom substrate cover, embeddedness values, and flow and had poor to fair habitat related to most other factors. Most habitat factors at the reference site were considered good to excellent. Part of the variation in biological condition scores was explained by physical habitat scores and concentrations of suspended solids and dissolved oxygen. However, a considerable amount of variability in biological condition scores is not explained by these factors.

  5. Occurrence and concentrations of selected trace elements and halogenated organic compounds in stream sediments and potential sources of polychlorinated biphenyls, Leon Creek, San Antonio, Texas, 2012–14

    USGS Publications Warehouse

    Wilson, Jennifer T.

    2016-06-23

    Sediment samples collected from Leon Creek by the USGS during 2007–9 and 2012–14 at a total of eight sites following identical field and laboratory methods were evaluated to determine if potential PCB sources could be identified. Total PCB concentrations in the sediment samples collected upstream from the Joint Base site were low or nondetections; while concentrations in the samples collected on and downstream from the Joint Base site were greater. Congeners 180 and 138 constituted the greatest proportion of the PCB mixture in samples collected upstream from, on, and downstream from the Joint Base site. Upstream from the Joint Base site, congeners 180 and 138 constituted 50 percent and 35 percent respectively of the PCBs congeners found in the samples. On and downstream from the Joint Base site, congeners 180 and 138 constituted 80 percent and 13 percent respectively of the PCBs congeners found in the samples. Chi-square (C2) tests also indicate that samples collected from the Loop 410 site were statistically different from samples collected from the Joint Base site and sites downstream. The PCB congener pattern in the Leon Creek samples is most like the congener mixture in Aroclor 1260, which is chemically similar to the PCBs detected in the fish samples that resulted in the 2003 fish consumption advisory.

  6. Hydrologic monitoring of selected streams in coal fields of central and southern Utah; summary of data collected, August 1978-September 1984

    USGS Publications Warehouse

    Price, Don; Plantz, G.G.

    1987-01-01

    The U.S. Geological Survey conducted a coal-hydrology monitoring program in coal-field areas of central and southern Utah during August 1978-September 1984 to determine possible hydrologic impacts of future mining and to provide a better understanding of the hydrologic systems of the coal resource areas monitored. Data were collected at 19 gaging stations--18 stations in the Price, San Rafael, and Dirty Devil River basins, and 1 in the Kanab Creek Basin. Streamflow data were collected continuously at 11 stations and seasonally at 5 stations. At the other three stations streamflow data were collected continuously during the 1979 water year and then seasonally for the rest of their periods of record. Types of data collected at each station included quantity and quality of streamflow; suspended sediment concentrations; and descriptions of stream bottom sediments, benthic invertebrate, and phytoplankton samples. Also, base flow measurements were made annually upstream from 12 of the gaging stations. Stream bottom sediment sampled at nearly all the monitoring sites contained small to moderate quantities of coal, which may be attributed chiefly to pre-monitoring mining. Streamflow sampled at several sites contained large concentrations of sulfate and dissolved solids. Also, concentrations of various trace elements at 10 stations, and phenols at 18 stations, exceeded the criteria of the EPA for drinking water. This may be attributed to contemporary (water years 1979-84) mine drainage activities. The data collected during the complete water years (1979-84) of monitoring do provide a better understanding of the hydrologic systems of the coal field areas monitored. The data also provide a definite base by which to evaluate hydrologic impacts of continued or increased coal mining in those areas. (Author 's abstract)

  7. Field tests of nylon-screen diffusion samplers and pushpoint samplers for detection of metals in sediment pore water, Ashland and Clinton, Massachusetts, 2003

    USGS Publications Warehouse

    Zimmerman, Marc J.; Vroblesky, Don A.; Campo, Kimberly W.; Massey, Andrew J.; Scheible, Walter

    2005-01-01

    Efficient and economical screening methods are needed to detect and to determine the approximate concentrations of potentially toxic trace-element metals in shallow groundwater- discharge areas (pore water) where the metals may pose threats to aquatic organisms; such areas are likely to be near hazardous-waste sites. Pushpoint and nylon-screen diffusion samplers are two complementary options for use in such environments. The pushpoint sampler, a simple well point, is easy to insert manually and to use. Only 1 day is required to collect samples. The nylon-screen diffusion sampler is well suited for use in sediments that do not allow a pump to draw water into a pushpoint sampler. In this study, both types of devices were used in sediments suitable for the use of the pushpoint sampler. Sampling with the nylon-screen diffusion sampler requires at least two site visits: one to deploy the samplers in the sediment, and a second to retrieve the samplers and collect the samples after a predetermined equilibration period. Extensive laboratory quality-control studies, field testing, and laboratory analysis of samples collected at the Nyanza Chemical Waste Dump Superfund site along the Sudbury River in Ashland, Massachusetts, and at a Superfund site-assessment location on Rigby Brook in Clinton, Massachusetts, indicate that these two devices yield comparable results for most metals and should be effective tools for pore-water studies. The nylon-screen diffusion samplers equilibrated within 1-2 days in homogeneous, controlled conditions in the laboratory. Nylon-screen diffusion samplers that were not purged of dissolved oxygen prior to deployment yielded results similar to those that were purged. Further testing of the nylon-screen diffusion samplers in homogeneous media would help to resolve any ambiguities about the data variability from the field studies. Comparison of data from replicate samples taken in both study areas shows that even samples taken from sites within a half-meter radius of one another have distinct differences in pore-water trace-element concentrations. Sequential replicate samples collected with the pushpoint sampler yield consistent results; moving the pushpoint sampler even 5 to 10 centimeters, however, generally produces a second set of data that differs enough from the first set of data to indicate a heterogeneous environment. High concentration biases for barium and zinc in laboratory and field samples collected with nylon-screen diffusion samplers, however, may make their use inappropriate for studies of these metals. Analyzing samples with high iron concentrations required sample dilution by factors of 2 or 10. Because these dilutions caused increases in the reporting levels by the same proportion, a substantial fraction of the data was censored. The results from undiluted samples, however, indicate that both devices should be useful for sampling ground water with metal concentrations close to reporting limits.

  8. Minerva: An Integrated Geospatial/Temporal Toolset for Real-time Science Decision Making and Data Collection

    NASA Astrophysics Data System (ADS)

    Lees, D. S.; Cohen, T.; Deans, M. C.; Lim, D. S. S.; Marquez, J.; Heldmann, J. L.; Hoffman, J.; Norheim, J.; Vadhavk, N.

    2016-12-01

    Minerva integrates three capabilities that are critical to the success of NASA analogs. It combines NASA's Exploration Ground Data Systems (xGDS) and Playbook software, and MIT's Surface Exploration Traverse Analysis and Navigation Tool (SEXTANT). Together, they help to plan, optimize, and monitor traverses; schedule and track activity; assist with science decision-making and document sample and data collection. Pre-mission, Minerva supports planning with a priori map data (e.g., UAV and satellite imagery) and activity scheduling. During missions, xGDS records and broadcasts live data to a distributed team who take geolocated notes and catalogue samples. Playbook provides live schedule updates and multi-media chat. Post-mission, xGDS supports data search and visualization for replanning and analysis. NASA's BASALT (Biologic Analog Science Associated with Lava Terrains) and FINESSE (Field Investigations to Enable Solar System Science and Exploration) projects use Minerva to conduct field science under simulated Mars mission conditions including 5 and 15 minute one-way communication delays. During the recent BASALT-FINESSE mission, two field scientists (EVA team) executed traverses across volcanic terrain to characterize and sample basalts. They wore backpacks with communications and imaging capabilities, and carried field portable spectrometers. The Science Team was 40 km away in a simulated mission control center. The Science Team monitored imaging (video and still), spectral, voice, location and physiological data from the EVA team via the network from the field, under communication delays. Minerva provided the Science Team with a unified context of operations at the field site, so they could make meaningful remote contributions to the collection of 10's of geotagged samples. Minerva's mission architecture will be presented with technical details and capabilities. Through the development, testing and application of Minerva, we are defining requirements for the design of future capabilities to support human and human-robotic missions to deep space and Mars.

  9. GeoLab's First Field Trials, 2010 Desert RATS: Evaluating Tools for Early Sample Characterization

    NASA Technical Reports Server (NTRS)

    Evans, Cindy A.; Bell, M. S.; Calaway, M. J.; Graff, Trevor; Young, Kelsey

    2011-01-01

    As part of an accelerated prototyping project to support science operations tests for future exploration missions, we designed and built a geological laboratory, GeoLab, that was integrated into NASA's first generation Habitat Demonstration Unit-1/Pressurized Excursion Module (HDU1-PEM). GeoLab includes a pressurized glovebox for transferring and handling samples collected on geological traverses, and a suite of instruments for collecting preliminary data to help characterize those samples. The GeoLab and the HDU1-PEM were tested for the first time as part of the 2010 Desert Research and Technology Studies (DRATS), NASA's analog field exercise for testing mission technologies. The HDU1- PEM and GeoLab participated in two weeks of joint operations in northern Arizona with two crewed rovers and the DRATS science team.

  10. Microbial Groundwater Sampling Protocol for Fecal-Rich Environments

    PubMed Central

    Harter, Thomas; Watanabe, Naoko; Li, Xunde; Atwill, Edward R; Samuels, William

    2014-01-01

    Inherently, confined animal farming operations (CAFOs) and other intense fecal-rich environments are potential sources of groundwater contamination by enteric pathogens. The ubiquity of microbial matter poses unique technical challenges in addition to economic constraints when sampling wells in such environments. In this paper, we evaluate a groundwater sampling protocol that relies on extended purging with a portable submersible stainless steel pump and Teflon® tubing as an alternative to equipment sterilization. The protocol allows for collecting a large number of samples quickly, relatively inexpensively, and under field conditions with limited access to capacity for sterilizing equipment. The protocol is tested on CAFO monitoring wells and considers three cross-contamination sources: equipment, wellbore, and ambient air. For the assessment, we use Enterococcus, a ubiquitous fecal indicator bacterium (FIB), in laboratory and field tests with spiked and blank samples, and in an extensive, multi-year field sampling campaign on 17 wells within 2 CAFOs. The assessment shows that extended purging can successfully control for equipment cross-contamination, but also controls for significant contamination of the well-head, within the well casing and within the immediate aquifer vicinity of the well-screen. Importantly, our tests further indicate that Enterococcus is frequently entrained in water samples when exposed to ambient air at a CAFO during sample collection. Wellbore and air contamination pose separate challenges in the design of groundwater monitoring strategies on CAFOs that are not addressed by equipment sterilization, but require adequate QA/QC procedures and can be addressed by the proposed sampling strategy. PMID:24903186

  11. Chapter A5. Section 6.1.F. Wastewater, Pharmaceutical, and Antibiotic Compounds

    USGS Publications Warehouse

    Lewis, Michael Edward; Zaugg, Steven D.

    2003-01-01

    The USGS differentiates between samples collected for analysis of wastewater compounds and those collected for analysis of pharmaceutical and antibiotic compounds, based on the analytical schedule for the laboratory method. Currently, only the wastewater laboratory method for field-filtered samples (SH1433) is an approved, routine (production) method. (The unfiltered wastewater method LC 8033 also is available but requires a proposal for custom analysis.) At this time, analysis of samples for pharmaceutical and antibiotic compounds is confined to research studies and is available only on a custom basis.

  12. Astronaut John Young photographed collecting lunar samples

    NASA Technical Reports Server (NTRS)

    1972-01-01

    Astronaut John W. Young, commander of the Apollo 16 lunar landing mission, is photographed collecting lunar samples near North Ray crater during the third Apollo 16 extravehicular activity (EVA-3) at the Descartes landing site. This picture was taken by Astronaut Charles M. Duke Jr., lunar module pilot. Young is using the lunar surface rake and a set of tongs. The Lunar Roving Vehicle is parked in the field of large boulders in the background.

  13. GIS-based smartphone application to support water quality data collection

    USDA-ARS?s Scientific Manuscript database

    Thorough registration of locations, conditions, and operations at sampling sites is essential for any field survey work. The collected information of this type has to be systematic, transferable, and accessible from different locations of data analysis. The handheld data-recording with smart devices...

  14. Sample Return Robot Centennial Challenge

    NASA Image and Video Library

    2012-06-16

    A judge for the NASA-WPI Sample Return Robot Centennial Challenge follows a robot on the playing field during the challenge on Saturday, June 16, 2012 in Worcester, Mass. Teams were challenged to build autonomous robots that can identify, collect and return samples. NASA needs autonomous robotic capability for future planetary exploration. Photo Credit: (NASA/Bill Ingalls)

  15. Evaluation of field sampling and preservation methods for strontium-90 in ground water at the Idaho National Engineering Laboratory, Idaho

    USGS Publications Warehouse

    Cecil, L.D.; Knobel, L.L.; Wegner, S.J.; Moore, L.L.

    1989-01-01

    Water from four wells completed in the Snake River Plain aquifer was sampled as part of the U.S. Geological Survey 's quality assurance program to evaluate the effect of filtration and preservation methods on strontium-90 concentrations in groundwater at the Idaho National Engineering Laboratory. Water from each well was filtered through either a 0.45-micrometer membrane or a 0.1-micrometer membrane filter; unfiltered samples also were collected. Two sets of filtered and two sets of unfiltered samples was preserved in the field with reagent-grade hydrochloric acid and the other set of samples was not acidified. For water from wells with strontium-90 concentrations at or above the reporting level, 94% or more of the strontium-90 is in true solution or in colloidal particles smaller than 0.1 micrometer. These results suggest that within-laboratory reproducibility for strontium-90 in groundwater at the INEL is not significantly affected by changes in filtration and preservation methods used for sample collections. (USGS)

  16. White HDPE bottles as source of serious contamination of water samples with Ba and Zn.

    PubMed

    Reimann, Clemens; Grimstvedt, Andreas; Frengstad, Bjørn; Finne, Tor Erik

    2007-03-15

    During a recent study of surface water quality factory new white high-density polyethylene (HDPE) bottles were used for collecting the water samples. According to the established field protocol of the Geological Survey of Norway the bottles were twice carefully rinsed with water in the field prior to sampling. Several blank samples using milli-Q (ELGA) water (>18.2 MOmega) were also prepared. On checking the analytical results the blanks returned values of Ag, Ba, Sr, V, Zn and Zr. For Ba and Zn the values (c. 300 microg/l and 95 microg/l) were about 10 times above the concentrations that can be expected in natural waters. A laboratory test of the bottles demonstrated that the bottles contaminate the samples with significant amounts of Ba and Zn and some Sr. Simple acid washing of the bottles prior to use did not solve the contamination problem for Ba and Zn. The results suggest that there may exist "clean" and "dirty" HDPE bottles depending on manufacturer/production process. When collecting water samples it is mandatory to check bottles regularly as a possible source of contamination.

  17. Evaluation of field sampling and preservation methods for strontium-90 in ground water at the Idaho National Engineering Laboratory, Idaho

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cecil, L.D.; Knobel, L.L.; Wegner, S.J.

    1989-01-01

    Water from four wells completed in the Snake River Plain aquifer was sampled as part of the US Geological Survey's quality assurance program to evaluate the effect of filtration and preservation methods on strontium-90 concentrations in groundwater at the Idaho National Engineering Laboratory. Water from each well was filtered through either a 0.45-micrometer membrane or a 0.1-micrometer membrane filter; unfiltered samples also were collected. Two sets of filtered and two sets of unfiltered samples was preserved in the field with reagent-grade hydrochloric acid and the other set of samples was not acidified. For water from wells with strontium-90 concentrations atmore » or above the reporting level, 94% or more of the strontium-90 is in true solution or in colloidal particles smaller than 0.1 micrometer. These results suggest that within-laboratory reproducibility for strontium-90 in groundwater at the INEL is not significantly affected by changes in filtration and preservation methods used for sample collections. 13 refs., 2 figs., 6 tabs.« less

  18. Herbicide sorption to fine particulate matter suspended downwind of agricultural operations: field and laboratory investigations.

    PubMed

    Clymo, Amelia S; Shin, Jin Young; Holmen, Britt A

    2005-01-15

    Tillage-induced erosion of herbicides bound to airborne soil particles has not been quantified as a mechanism for offsite herbicide transport. This study quantifies the release of two preemergent herbicides, metolachlor and pendimethalin, to the atmosphere as gas- and particle-phase species during soil incorporation operations. Fine particulate matter (PM2.5) and gas-phase samples were collected at three sampling heights during herbicide disking into the soil in Davis, CA, in May 2000 and May 2001 using filter/PUF sampling. Quartz fiber filters (QFFs) were used in May 2000, and Teflon membrane filters (TMFs) were used in May 2001. The field data were combined with laboratory filter/PUF partitioning experiments to account for adsorption to the filter surfaces and quantify the mass of PM2.5-bound herbicides in the field samples. Laboratory results indicate a significant adsorption of metolachlor, but not pendimethalin, to the quartz filter surfaces. Metolachlor partitioning to PM2.5 collected on TMF filters resulted in corrected PM2.5 field partition coefficient values, Kp,corr = Cp/Cg, of approximately 10(-3.5) m3/microg, indicating its preference for the gas phase. Pendimethalin exhibited more semivolatile behavior,with Kp,corr values that ranged from 10(-3) to 10(-1) m3/ microg and increased with sampling height and distance downwind of the operation. An increase in pendimethalin enrichment at a height of 5 m suggests winnowing of finer, more sorptive soil components with corresponding higher transport potential. Pendimethalin was enriched in the PM2.5 samples by up to a factor of 250 compared to the field soil, indicating thatfurther research on the processes controlling the generation of PM-bound herbicides during agricultural operations is warranted to enable prediction of off-site mass fluxes by this mechanism.

  19. RECRUITMENT AND FIELD SAMPLING IN THE CTEPP NORTH CAROLINA AND OHIO FIELD STUDIES

    EPA Science Inventory

    Recruiting study participants is always a challenge for researchers. It is more of a challenge when researchers have to recruit participants for a study involving intrusive, burdensome data collection activities. In this presentation, we describe our recruitment strategies and ...

  20. DIETARY EXPOSURES OF YOUNG CHILDREN, PART II: FIELD STUDY

    EPA Science Inventory

    A small, pilot field study was conducted to determine the adequacy of protocols for dietary exposure measurements. Samples were collected to estimate the amount of pesticides transferred from contaminated surfaces or hands to foods of young children and to validate a dietary mod...

  1. The Luizi Structure (Democratic Republic of Congo) — First Confirmed Meteorite Impact Crater in Central Africa

    NASA Astrophysics Data System (ADS)

    Ferrière, L.; Lubala, F. R. T.; Osinski, G. R.; Kaseti, P. K.

    2011-03-01

    Our detailed analysis of the Luizi structure, combining a remote sensing study with geological field observations and petrographic examination of rock samples collected during our 2010 field campaign allows us to confirm its meteorite impact origin.

  2. Guidelines for collection and field analysis of water-quality samples from streams in Texas

    USGS Publications Warehouse

    Wells, F.C.; Gibbons, W.J.; Dorsey, M.E.

    1990-01-01

    Analyses for unstable constituents or properties are by necessity performed in the field. This manual addresses analytical techniques and quality assurance for: (1) Water temperature; (2) specific conductance; (3) pH; (4) alkalinity; (5) dissolved oxygen; and (6) bacteria.

  3. [Mercury and creatinine in urine of employees exposed to magnetic fields. A study of a group electrolysis-operators in Norzink A/S in Odda].

    PubMed

    Schmidt, F; Mannsåker

    1997-01-20

    The results described are based on a study of 26 male cell house employees. They were exposed to a combination of static magnetic fields (3-10 mT) and low frequency oscillating magnetic fields of variable frequency and strength for eight hours a day over a period of four weeks. Every fifth week was spent off work. Urine samples collected at the end of the four weeks of exposure were compared with samples collected at the end of the week off work. The results show that the cell house workers excreted significantly more mercury in their urine after exposure to magnetic fields (p = 0.01). The mercury/creatinine ratio was also significantly higher after exposure (p < 0.01). These results support findings by Schmidt in a study from 1992 when the levels of mercury and creatinine in the urine of cell house workers were compared with the levels in office personnel.

  4. NHEXAS PHASE I ARIZONA STUDY--LIST OF STANDARD OPERATING PROCEDURES

    EPA Science Inventory

    This document lists available protocols and SOPs for the NHEXAS Phase I Arizona study. It identifies protocols and SOPs for the following study components: (1) Sample collection and field operations, (2) Sample analysis, (3) General laboratory procedures, (4) Quality Assurance, (...

  5. Isothermal amplification of environmental DNA (eDNA) for direct field-based monitoring and laboratory confirmation of Dreissena sp.

    PubMed

    Williams, Maggie R; Stedtfeld, Robert D; Engle, Cathrine; Salach, Paul; Fakher, Umama; Stedtfeld, Tiffany; Dreelin, Erin; Stevenson, R Jan; Latimore, Jo; Hashsham, Syed A

    2017-01-01

    Loop-mediated isothermal amplification (LAMP) of aquatic invasive species environmental DNA (AIS eDNA) was used for rapid, sensitive, and specific detection of Dreissena sp. relevant to the Great Lakes (USA) basin. The method was validated for two uses including i) direct amplification of eDNA using a hand filtration system and ii) confirmation of the results after DNA extraction using a conventional thermal cycler run at isothermal temperatures. Direct amplification eliminated the need for DNA extraction and purification and allowed detection of target invasive species in grab or concentrated surface water samples, containing both free DNA as well as larger cells and particulates, such as veligers, eggs, or seeds. The direct amplification method validation was conducted using Dreissena polymorpha and Dreissena bugensis and uses up to 1 L grab water samples for high target abundance (e.g., greater than 10 veligers (larval mussels) per L for Dreissena sp.) or 20 L samples concentrated through 35 μm nylon screens for low target abundance, at less than 10 veligers per liter water. Surface water concentrate samples were collected over a period of three years, mostly from inland lakes in Michigan with the help of a network of volunteers. Field samples collected from 318 surface water locations included i) filtered concentrate for direct amplification validation and ii) 1 L grab water sample for eDNA extraction and confirmation. Though the extraction-based protocol was more sensitive (resulting in more positive detections than direct amplification), direct amplification could be used for rapid screening, allowing for quicker action times. For samples collected between May and August, results of eDNA direct amplification were consistent with known presence/absence of selected invasive species. A cross-platform smartphone application was also developed to disseminate the analyzed results to volunteers. Field tests of the direct amplification protocol using a portable device (Gene-Z) showed the method could be used in the field to obtain results within one hr (from sample to result). Overall, the direct amplification has the potential to simplify the eDNA-based monitoring of multiple aquatic invasive species. Additional studies are warranted to establish quantitative correlation between eDNA copy number, veliger, biomass or organismal abundance in the field.

  6. Isothermal amplification of environmental DNA (eDNA) for direct field-based monitoring and laboratory confirmation of Dreissena sp.

    PubMed Central

    Stedtfeld, Robert D.; Engle, Cathrine; Salach, Paul; Fakher, Umama; Stedtfeld, Tiffany; Dreelin, Erin; Stevenson, R. Jan; Latimore, Jo; Hashsham, Syed A.

    2017-01-01

    Loop-mediated isothermal amplification (LAMP) of aquatic invasive species environmental DNA (AIS eDNA) was used for rapid, sensitive, and specific detection of Dreissena sp. relevant to the Great Lakes (USA) basin. The method was validated for two uses including i) direct amplification of eDNA using a hand filtration system and ii) confirmation of the results after DNA extraction using a conventional thermal cycler run at isothermal temperatures. Direct amplification eliminated the need for DNA extraction and purification and allowed detection of target invasive species in grab or concentrated surface water samples, containing both free DNA as well as larger cells and particulates, such as veligers, eggs, or seeds. The direct amplification method validation was conducted using Dreissena polymorpha and Dreissena bugensis and uses up to 1 L grab water samples for high target abundance (e.g., greater than 10 veligers (larval mussels) per L for Dreissena sp.) or 20 L samples concentrated through 35 μm nylon screens for low target abundance, at less than 10 veligers per liter water. Surface water concentrate samples were collected over a period of three years, mostly from inland lakes in Michigan with the help of a network of volunteers. Field samples collected from 318 surface water locations included i) filtered concentrate for direct amplification validation and ii) 1 L grab water sample for eDNA extraction and confirmation. Though the extraction-based protocol was more sensitive (resulting in more positive detections than direct amplification), direct amplification could be used for rapid screening, allowing for quicker action times. For samples collected between May and August, results of eDNA direct amplification were consistent with known presence/absence of selected invasive species. A cross-platform smartphone application was also developed to disseminate the analyzed results to volunteers. Field tests of the direct amplification protocol using a portable device (Gene-Z) showed the method could be used in the field to obtain results within one hr (from sample to result). Overall, the direct amplification has the potential to simplify the eDNA-based monitoring of multiple aquatic invasive species. Additional studies are warranted to establish quantitative correlation between eDNA copy number, veliger, biomass or organismal abundance in the field. PMID:29036210

  7. BioDry: An Inexpensive, Low-Power Method to Preserve Aquatic Microbial Biomass at Room Temperature.

    PubMed

    Tuorto, Steven J; Brown, Chris M; Bidle, Kay D; McGuinness, Lora R; Kerkhof, Lee J

    2015-01-01

    This report describes BioDry (patent pending), a method for reliably preserving the biomolecules associated with aquatic microbial biomass samples, without the need of hazardous materials (e.g. liquid nitrogen, preservatives, etc.), freezing, or bulky storage/sampling equipment. Gel electrophoresis analysis of nucleic acid extracts from samples treated in the lab with the BioDry method indicated that molecular integrity was protected in samples stored at room temperature for up to 30 days. Analysis of 16S/18S rRNA genes for presence/absence and relative abundance of microorganisms using both 454-pyrosequencing and TRFLP profiling revealed statistically indistinguishable communities from control samples that were frozen in liquid nitrogen immediately after collection. Seawater and river water biomass samples collected with a portable BioDry "field unit", constructed from off-the-shelf materials and a battery-operated pumping system, also displayed high levels of community rRNA preservation, despite a slight decrease in nucleic acid recovery over the course of storage for 30 days. Functional mRNA and protein pools from the field samples were also effectively conserved with BioDry, as assessed by respective RT-PCR amplification and western blot of ribulose-1-5-bisphosphate carboxylase/oxygenase. Collectively, these results demonstrate that BioDry can adequately preserve a suite of biomolecules from aquatic biomass at ambient temperatures for up to a month, giving it great potential for high resolution sampling in remote locations or on autonomous platforms where space and power are limited.

  8. BioDry: An Inexpensive, Low-Power Method to Preserve Aquatic Microbial Biomass at Room Temperature

    PubMed Central

    Tuorto, Steven J.; Brown, Chris M.; Bidle, Kay D.; McGuinness, Lora R.; Kerkhof, Lee J.

    2015-01-01

    This report describes BioDry (patent pending), a method for reliably preserving the biomolecules associated with aquatic microbial biomass samples, without the need of hazardous materials (e.g. liquid nitrogen, preservatives, etc.), freezing, or bulky storage/sampling equipment. Gel electrophoresis analysis of nucleic acid extracts from samples treated in the lab with the BioDry method indicated that molecular integrity was protected in samples stored at room temperature for up to 30 days. Analysis of 16S/18S rRNA genes for presence/absence and relative abundance of microorganisms using both 454-pyrosequencing and TRFLP profiling revealed statistically indistinguishable communities from control samples that were frozen in liquid nitrogen immediately after collection. Seawater and river water biomass samples collected with a portable BioDry “field unit", constructed from off-the-shelf materials and a battery-operated pumping system, also displayed high levels of community rRNA preservation, despite a slight decrease in nucleic acid recovery over the course of storage for 30 days. Functional mRNA and protein pools from the field samples were also effectively conserved with BioDry, as assessed by respective RT-PCR amplification and western blot of ribulose-1-5-bisphosphate carboxylase/oxygenase. Collectively, these results demonstrate that BioDry can adequately preserve a suite of biomolecules from aquatic biomass at ambient temperatures for up to a month, giving it great potential for high resolution sampling in remote locations or on autonomous platforms where space and power are limited. PMID:26710122

  9. Urban Land Cover Mapping Accuracy Assessment - A Cost-benefit Analysis Approach

    NASA Astrophysics Data System (ADS)

    Xiao, T.

    2012-12-01

    One of the most important components in urban land cover mapping is mapping accuracy assessment. Many statistical models have been developed to help design simple schemes based on both accuracy and confidence levels. It is intuitive that an increased number of samples increases the accuracy as well as the cost of an assessment. Understanding cost and sampling size is crucial in implementing efficient and effective of field data collection. Few studies have included a cost calculation component as part of the assessment. In this study, a cost-benefit sampling analysis model was created by combining sample size design and sampling cost calculation. The sampling cost included transportation cost, field data collection cost, and laboratory data analysis cost. Simple Random Sampling (SRS) and Modified Systematic Sampling (MSS) methods were used to design sample locations and to extract land cover data in ArcGIS. High resolution land cover data layers of Denver, CO and Sacramento, CA, street networks, and parcel GIS data layers were used in this study to test and verify the model. The relationship between the cost and accuracy was used to determine the effectiveness of each sample method. The results of this study can be applied to other environmental studies that require spatial sampling.

  10. Selected water-quality data from the Cedar River and Cedar Rapids well fields, Cedar Rapids, Iowa, 2006-10

    USGS Publications Warehouse

    Littin, Gregory R.

    2012-01-01

    The Cedar River alluvial aquifer is the primary source of municipal water in the Cedar Rapids, Iowa area. Municipal wells are completed in the alluvial aquifer approximately 40 to 80 feet below land surface. The City of Cedar Rapids and the U.S. Geological Survey have been conducting a cooperative study of the groundwater-flow system and water quality of the aquifer since 1992. Cooperative reports between the City of Cedar Rapids and the U.S. Geological Survey have documented hydrologic and water-quality data, geochemistry, and groundwater models. Water-quality samples were collected for studies involving well field monitoring, trends, source-water protection, groundwater geochemistry, surface-water-groundwater interaction, and pesticides in groundwater and surface water. Water-quality analyses were conducted for major ions (boron, bromide, calcium, chloride, fluoride, iron, magnesium, manganese, potassium, silica, sodium, and sulfate), nutrients (ammonia as nitrogen, nitrite as nitrogen, nitrite plus nitrate as nitrogen, and orthophosphate as phosphorus), dissolved organic carbon, and selected pesticides including two degradates of the herbicide atrazine. Physical characteristics (alkalinity, dissolved oxygen, pH, specific conductance and water temperature) were measured in the field and recorded for each water sample collected. This report presents the results of routine water-quality data-collection activities from January 2006 through December 2010. Methods of data collection, quality-assurance, and water-quality analyses are presented. Data include the results of water-quality analyses from quarterly sampling from monitoring wells, municipal wells, and the Cedar River.

  11. Site-based data curation based on hot spring geobiology

    PubMed Central

    Palmer, Carole L.; Thomer, Andrea K.; Baker, Karen S.; Wickett, Karen M.; Hendrix, Christie L.; Rodman, Ann; Sigler, Stacey; Fouke, Bruce W.

    2017-01-01

    Site-Based Data Curation (SBDC) is an approach to managing research data that prioritizes sharing and reuse of data collected at scientifically significant sites. The SBDC framework is based on geobiology research at natural hot spring sites in Yellowstone National Park as an exemplar case of high value field data in contemporary, cross-disciplinary earth systems science. Through stakeholder analysis and investigation of data artifacts, we determined that meaningful and valid reuse of digital hot spring data requires systematic documentation of sampling processes and particular contextual information about the site of data collection. We propose a Minimum Information Framework for recording the necessary metadata on sampling locations, with anchor measurements and description of the hot spring vent distinct from the outflow system, and multi-scale field photography to capture vital information about hot spring structures. The SBDC framework can serve as a global model for the collection and description of hot spring systems field data that can be readily adapted for application to the curation of data from other kinds scientifically significant sites. PMID:28253269

  12. Biosorption of phenanthrene by pure algae and field-collected planktons and their fractions.

    PubMed

    Zhang, Dainan; Ran, Chenyang; Yang, Yu; Ran, Yong

    2013-09-01

    The biosorption isotherms for phenanthrene (Phen) by cultured algae, field-collected plankton, and market algae samples (OSs) and their fractions (lipid-LP, lipid free carbon-LF, alkaline nonhydrolyzable carbon-ANHC, and acid nonhydrolyzable carbon-NHC) were established. All the biosorption isotherms are well fitted by the Freundlich model. The biosorption isotherms for the ANHC and NHC fractions are nonlinear and for the other fractions are linear. It was found that the NHC fractions are chemically and structurally different from other fractions by using elemental analysis and Fourier transformed infrared spectroscopy (FTIR), consisting mainly of aliphatic polymethylene carbon. The average KOC values for Phen at Ce=0.005Sw are 10706±2768mLg(-1) and 95843±55817mLg(-1) for the bulk market algal samples and their NHC isolates, respectively. As the NHC fraction for Porphyra contains higher polymethylene carbon than that for Seaweed or Spirulina, it exhibits higher biosorption capacity. Moreover, the logKOC values are significantly higher for the field-collected samples than for the market algae and cultured algae samples. The multivariate correlation shows that the logKOC values are positively related to the LP contents, and negatively to the C/N ratios for the original algal samples. Furthermore, the logKOC values are negatively related to the polarity indices (O/C and O+N/C) for the original samples and their fractions excluding LP fractions. These observations help to understand the role of polarity, LP and NHC fractions, and aliphatic structures in the biosorption of Phen, which requires more attention in the examination of sorption processes in the natural environment. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Loop-mediated isothermal amplification (LAMP) assay for the identification of Echinococcus multilocularis infections in canine definitive hosts.

    PubMed

    Ni, Xingwei; McManus, Donald P; Yan, Hongbin; Yang, Jifei; Lou, Zhongzi; Li, Hongmin; Li, Li; Lei, Mengtong; Cai, Jinzhong; Fan, Yanlei; Li, Chunhua; Liu, Quanyuan; Shi, Wangui; Liu, Xu; Zheng, Yadong; Fu, Baoquan; Yang, Yurong; Jia, Wanzhong

    2014-05-30

    Alveolar echinococcosis, caused by the metacestode larval stage of Echinococcus multilocularis, is a zoonosis of public health significance and is highly prevalent in northwest China. To effectively monitor its transmission, we developed a new rapid and cheap diagnostic assay, based on loop-mediated isothermal amplification (LAMP), to identify canine definitive hosts infected with E. multilocularis. The primers used in the LAMP assay were based on the mitochondrial nad5 gene of E. multilocularis and were designed using Primer Explorer V4 software. The developed LAMP assay was compared with a conventional PCR assay, using DNA extracted from the feces of dogs experimentally infected with E. multilocularis, on 189 dog fecal samples collected from three E. multilocularis-endemic regions in Qinghai province, the People's Republic of China, and 30 negative control copro-samples from dogs from an area in Gansu province that had been subjected to an intensive de-worming program. Light microscopy was also used to examine the experimentally obtained and field collected dog copro-samples for the presence of E. multilocularis eggs. The E. multilocularis-positivity rates obtained for the field-collected fecal samples were 16.4% and 5.3% by the LAMP and PCR assays, respectively, and all samples obtained from the control dogs were negative. The LAMP assay was able to detect E. multilocularis DNA in the feces of experimentally infected dogs at 12 days post-infection, whereas the PCR assay was positive on the 17th day and eggs were first detectable by light microscopy at day 44 post-challenge. The earlier specific detection of an E. multilocularis infection in dog copro-samples indicates that the LAMP assay we developed is a realistic alternative method for the field surveillance of canines in echinococcosis-endemic areas.

  14. U14 : field testing & analysis of braking performance of in-service trucks.

    DOT National Transportation Integrated Search

    2009-06-01

    The purpose of this project was to collect a high quality data set to provide a snapshot of the braking capability of a representative sampling of in-service commercial motor vehicles (CMVs) on the road today. This data collection effort is important...

  15. Preparation of Plant Samples for Phytochemical Research and the Study of Their Biological Activities

    USDA-ARS?s Scientific Manuscript database

    Prior to investigating plant natural products for biologically active constituents, it is necessary to establish guidelines and procedures for carefully collecting, cataloging, and storing specimens. All field collections should begin with detailed records on location, which should include a list o...

  16. Bacteria in midguts of field-collected Anopheles albimanus block Plasmodium vivax sporogonic development.

    PubMed

    Gonzalez-Ceron, Lilia; Santillan, Frida; Rodriguez, Mario H; Mendez, Domingo; Hernandez-Avila, Juan E

    2003-05-01

    Bacterial infections were investigated in midguts of insectary and field-collected Anopheles albimanus Weidemann from southern Mexico. Serratia marcescens, Enterobacter cloacae and Enterobacter amnigenus 2, Enterobacter sp., and Serratia sp. were isolated in field samples obtained in 1998, but only Enterobacter sp. was recovered in field samples of 1997 and no bacteria were isolated from insectary specimens. These bacteria were offered along with Plasmodium vivax infected blood to aseptic insectary An. albimanus, and the number of infected mosquitoes as well as the oocyst densities assessed after 7d. Plasmodium vivax infections in mosquitoes co-infected with En. amnigenus 2, En. cloacae, and S. marcensces were 53, 17, and 210 times, respectively, lower than in control mosquitoes, and the mean oocyst density in mosquitoes co-infected with En. cloacae was 2.5 times lower than in controls. Mortality was 13 times higher in S. marcensces-infected mosquitoes compared with controls. The overall midgut bacterial infection in mosquito field populations may influence P. vivax transmission, and could contribute to explain the annual variations in malaria incidence observed in the area.

  17. Field evaluation of the error arising from inadequate time averaging in the standard use of depth-integrating suspended-sediment samplers

    USGS Publications Warehouse

    Topping, David J.; Rubin, David M.; Wright, Scott A.; Melis, Theodore S.

    2011-01-01

    Several common methods for measuring suspended-sediment concentration in rivers in the United States use depth-integrating samplers to collect a velocity-weighted suspended-sediment sample in a subsample of a river cross section. Because depth-integrating samplers are always moving through the water column as they collect a sample, and can collect only a limited volume of water and suspended sediment, they collect only minimally time-averaged data. Four sources of error exist in the field use of these samplers: (1) bed contamination, (2) pressure-driven inrush, (3) inadequate sampling of the cross-stream spatial structure in suspended-sediment concentration, and (4) inadequate time averaging. The first two of these errors arise from misuse of suspended-sediment samplers, and the third has been the subject of previous study using data collected in the sand-bedded Middle Loup River in Nebraska. Of these four sources of error, the least understood source of error arises from the fact that depth-integrating samplers collect only minimally time-averaged data. To evaluate this fourth source of error, we collected suspended-sediment data between 1995 and 2007 at four sites on the Colorado River in Utah and Arizona, using a P-61 suspended-sediment sampler deployed in both point- and one-way depth-integrating modes, and D-96-A1 and D-77 bag-type depth-integrating suspended-sediment samplers. These data indicate that the minimal duration of time averaging during standard field operation of depth-integrating samplers leads to an error that is comparable in magnitude to that arising from inadequate sampling of the cross-stream spatial structure in suspended-sediment concentration. This random error arising from inadequate time averaging is positively correlated with grain size and does not largely depend on flow conditions or, for a given size class of suspended sediment, on elevation above the bed. Averaging over time scales >1 minute is the likely minimum duration required to result in substantial decreases in this error. During standard two-way depth integration, a depth-integrating suspended-sediment sampler collects a sample of the water-sediment mixture during two transits at each vertical in a cross section: one transit while moving from the water surface to the bed, and another transit while moving from the bed to the water surface. As the number of transits is doubled at an individual vertical, this error is reduced by ~30 percent in each size class of suspended sediment. For a given size class of suspended sediment, the error arising from inadequate sampling of the cross-stream spatial structure in suspended-sediment concentration depends only on the number of verticals collected, whereas the error arising from inadequate time averaging depends on both the number of verticals collected and the number of transits collected at each vertical. Summing these two errors in quadrature yields a total uncertainty in an equal-discharge-increment (EDI) or equal-width-increment (EWI) measurement of the time-averaged velocity-weighted suspended-sediment concentration in a river cross section (exclusive of any laboratory-processing errors). By virtue of how the number of verticals and transits influences the two individual errors within this total uncertainty, the error arising from inadequate time averaging slightly dominates that arising from inadequate sampling of the cross-stream spatial structure in suspended-sediment concentration. Adding verticals to an EDI or EWI measurement is slightly more effective in reducing the total uncertainty than adding transits only at each vertical, because a new vertical contributes both temporal and spatial information. However, because collection of depth-integrated samples at more transits at each vertical is generally easier and faster than at more verticals, addition of a combination of verticals and transits is likely a more practical approach to reducing the total uncertainty in most field situatio

  18. Advanced sampling techniques for hand-held FT-IR instrumentation

    NASA Astrophysics Data System (ADS)

    Arnó, Josep; Frunzi, Michael; Weber, Chris; Levy, Dustin

    2013-05-01

    FT-IR spectroscopy is the technology of choice to identify solid and liquid phase unknown samples. The challenging ConOps in emergency response and military field applications require a significant redesign of the stationary FT-IR bench-top instruments typically used in laboratories. Specifically, field portable units require high levels of resistance against mechanical shock and chemical attack, ease of use in restrictive gear, extreme reliability, quick and easy interpretation of results, and reduced size. In the last 20 years, FT-IR instruments have been re-engineered to fit in small suitcases for field portable use and recently further miniaturized for handheld operation. This article introduces the HazMatID™ Elite, a FT-IR instrument designed to balance the portability advantages of a handheld device with the performance challenges associated with miniaturization. In this paper, special focus will be given to the HazMatID Elite's sampling interfaces optimized to collect and interrogate different types of samples: accumulated material using the on-board ATR press, dispersed powders using the ClearSampler™ tool, and the touch-to-sample sensor for direct liquid sampling. The application of the novel sample swipe accessory (ClearSampler) to collect material from surfaces will be discussed in some detail. The accessory was tested and evaluated for the detection of explosive residues before and after detonation. Experimental results derived from these investigations will be described in an effort to outline the advantages of this technology over existing sampling methods.

  19. A data base of geologic field spectra

    NASA Technical Reports Server (NTRS)

    Kahle, A. B.; Goetz, A. F. H.; Paley, H. N.; Alley, R. E.; Abbott, E. A.

    1981-01-01

    It is noted that field samples measured in the laboratory do not always present an accurate picture of the ground surface sensed by airborne or spaceborne instruments because of the heterogeneous nature of most surfaces and because samples are disturbed and surface characteristics changed by collection and handling. The development of new remote sensing instruments relies on the analysis of surface materials in their natural state. The existence of thousands of Portable Field Reflectance Spectrometer (PFRS) spectra has necessitated a single, all-inclusive data base that permits greatly simplified searching and sorting procedures and facilitates further statistical analyses. The data base developed at JPL for cataloging geologic field spectra is discussed.

  20. A technique for measuring petal gloss, with examples from the Namaqualand flora.

    PubMed

    Whitney, Heather M; Rands, Sean A; Elton, Nick J; Ellis, Allan G

    2012-01-01

    The degree of floral gloss varies between species. However, little is known about this distinctive floral trait, even though it could be a key feature of floral biotic and abiotic interactions. One reason for the absence of knowledge is the lack of a simple, repeatable method of gloss measurement that can be used in the field to study floral gloss. A protocol is described for measuring gloss in petal samples collected in the field, using a glossmeter. Repeatability of the technique is assessed. We demonstrate a simple yet highly accurate and repeatable method that can easily be implemented in the field. We also highlight the huge variety of glossiness found within flowers and between species in a sample of spring-blooming flowers collected in Namaqualand, South Africa. We discuss the potential uses of this method and its applications for furthering studies in plant-pollinator interactions. We also discuss the potential functions of gloss in flowers.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rice, K.; Bricker, O.

    The report describes the results of a study to assess the sensitivity of streams to acidic deposition in Charles and Anne Arundel Counties, Maryland using a geology-based method. Water samples were collected from streams in July and August 1988 when streams were at base-flow conditions. Eighteen water samples collected from streams in Charles County, and 17 water samples from streams in Anne Arundel County were analyzed in the field for pH, specific conductance, and acid-neutralizing capacity (ANC); 8 water samples from streams in Charles County were analyzed in the laboratory for chloride and sulfate concentrations. The assessment revealed that streamsmore » in these counties are sensitive to acidification by acidic deposition.« less

  2. Hydrologic conditions, groundwater quality, and analysis of sink hole formation in the Albany area of Dougherty County, Georgia, 2009

    USGS Publications Warehouse

    Gordon, Debbie W.; Painter, Jaime A.; McCranie, John M.

    2012-01-01

    The U.S. Geological Survey, in cooperation with the Albany Water, Gas, and Light Commission has conducted water resources investigations and monitored groundwater conditions and availability in the Albany, Georgia, area since 1977. This report presents an overview of hydrologic conditions, water quality, and groundwater studies in the Albany area of Dougherty County, Georgia, during 2009. Historical data also are presented for comparison with 2009 data. During 2009, groundwater-level data were collected in 29 wells in the Albany area to monitor water-level trends in the surficial, Upper Floridan, Claiborne, Clayton, and Providence aquifers. Groundwater-level data from 21 of the 29 wells indicated an increasing trend during 2008–09. Five wells show no trend due to lack of data and three wells have decreasing trends. Period-of-record water levels (period of record ranged between 1957–2009 and 2003–2009) declined slightly in 10 wells and increased slightly in 4 wells tapping the Upper Floridan aquifer; declined in 1 well and increased in 2 wells tapping the Claiborne aquifer; declined in 4 wells and increased in 2 wells tapping the Clayton aquifer; and increased in 1 well tapping the Providence aquifer. Analyses of groundwater samples collected during 2009 from 12 wells in the Upper Floridan aquifer in the vicinity of a well field located southwest of Albany indicate that overall concentrations of nitrate plus nitrite as nitrogen increased slightly from 2008 in 8 wells. A maximum concentration of 12.9 milligrams per liter was found in a groundwater sample from a well located upgradient from the well field. The distinct difference in chemical constituents of water samples collected from the Flint River and samples collected from wells located in the well-field area southwest of Albany indicates that little water exchange occurs between the Upper Floridan aquifer and Flint River where the river flows adjacent to, but downgradient of, the well field. Water-quality data collected during 2008 from two municipal wells located in northern Albany and downgradient from a hazardous waste site indicate low-level concentrations of pesticides in one of the wells; however, no pesticides were detected in samples collected during 2009. Detailed geologic cross sections were used to create a three-dimensional, hydrogeologic diagram of the well field southwest of Albany in order to examine the occurrence of subsurface features conducive to sinkhole formation. Monitored groundwater-level data were used to assess the possible relations between sinkhole formation, precipitation, and water levels in the Upper Floridan aquifer. Although the water levels in well 12L382 oscillated above and below the top of the aquifer on a regular basis between 2007 and 2009, sinkhole development did not appear to correlate directly with either well-field pumping or water levels in the Upper Floridan aquifer. Specifically, two sinkholes formed in each of the years 2003 and 2005 when water levels were almost 20 feet above the top of the aquifer during most of the year. Water-level and sinkhole-formation data continue to be collected to allow further study and analysis.

  3. Genetic diversity and structure of Phakopsora pachyrhizi infecting soybean in Nigeria

    USDA-ARS?s Scientific Manuscript database

    The genetic structure of Nigerian field populations of the soybean rust pathogen Phakopsora pachyrhizi was determined using 18 simple sequence repeat markers. A total of 113 fungal isolates was collected by hierarchical sampling infected leaves from soybean fields in three agroecological zones in 2...

  4. Nature and origin of mineral coatings on volcanic rocks of the Black Mountain, Stonewall Mountain and Kane Springs wash volcanic centers, southern Nevada

    NASA Technical Reports Server (NTRS)

    Taranik, James V.; Noble, Donald C.; Hsu, Liang C.; Spatz, David M.

    1987-01-01

    Mineral coatings, including desert varnish on volcanic rocks of the semi-arid Basin and Range province are composted of amorphous, translucent films of Fe, Mn, Si, and Al rich compounds. Coatings are chiefly thin films that impregnate intergranularly to depths of about 0.1 to 0.3 mm, rarely deeper. Sixteen coating sections and subsurface interiors were probed by SEM; 20 samples were scanned by infrated spectrometry; 10 samples were scanned for visible-near IR spectra; inductin coupling plasma analyses were collected on 34 samples; 2 desert varnish surgaces were investigated by optical density slice imagery; a few XRD analyses were conducted in addition to the 50 reported in the last period; thin section observation continued; and imagery processing focused on classification techniques. In late May, approximately 10 field days were spent at the Stonewall and Black Mountain study sited conducting more detailed mapping and observation base on imagery results and collecting spectra with the Collins Field Spectrometer. Approximately 100 spectral analyses were collected and are currently being processed.

  5. NHEXAS PHASE I MARYLAND STUDY--LIST OF AVAILABLE DOCUMENTS: PROTOCOLS AND SOPS

    EPA Science Inventory

    This document lists available protocols and SOPs for the NHEXAS Phase I Maryland study. It identifies protocols and SOPs for the following study components: (1) Sample collection and field operations, (2) Sample analysis and general laboratory procedures, (3) Data Analysis Proced...

  6. Biosorption of nonylphenol by pure algae, field-collected planktons and their fractions.

    PubMed

    Zhang, Dainan; Ran, Yong; Cao, Xiaoyan; Mao, Jingdong; Cui, Jinfang; Schmidt-Rohr, Klaus

    2015-03-01

    Algal samples were fractionated into lipid (LP), lipid free (LF), alkaline nonhydrolyzable carbon (ANHC), and acid nonhydrolyzable carbon (NHC) fractions, and were characterized by the quantitative (13)C multiCP NMR technique. The biosorption isotherms for nonylphenol (NP) were established and compared with previously published data for phenanthrene (Phen). The log KOC values are significantly higher for the field-collected plankton samples than for the commercial algae and cultured algae samples, correlating with their lipid contents and aliphatic carbon structure. As the NHC fraction contains more poly(methylene) carbon, it exhibits a higher biosorption capacity. The sorption capacities are negatively related to the polarity index, COO/N-C=O, polar C and O-alkyl C concentrations, but are positively related to the H/O atomic ratios and poly(methylene) carbon. The higher sorption capacities observed for NP than for Phen on the investigated samples are explained by specific interactions such as hydrogen bonding and π-π interaction. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Hepatitis E virus and coliphages in waters proximal to swine concentrated animal feeding operations.

    PubMed

    Gentry-Shields, Jennifer; Myers, Kevin; Pisanic, Nora; Heaney, Christopher; Stewart, Jill

    2015-02-01

    North Carolina is the second leading state in pork production in the United States, with over 10 million swine. Swine manure in NC is typically collected and stored in open-pit lagoons before the liquid waste is sprayed onto agricultural fields for disposal. Components of this waste may be able to impact surface water quality with the potential for human exposure. This study examined viruses of public health concern in creeks adjacent to swine concentrated animal feeding operation (CAFO) spray fields. Surface water samples (n=154) were collected from public access waters in proximity to swine CAFO spray fields for six months and were tested for hepatitis E virus (HEV) and coliphages. HEV was detected in one sample. Somatic coliphages were detected in 98% of samples (geometric mean 24 ± 4.1 PFU per 100 ml), and F+ coliphages were detected in 85% of samples (geometric mean 6.8 ± 5.0 PFU per 100 ml). Only 3% (21) of the F+ coliphage isolates were RNA phage, and all of the F+ RNA coliphages belonged to genogroup I. Although the pervasiveness of swine CAFOs in this area prevented a comparison with samples from un-impacted sites, the near ubiquity of coliphages, as well as the presence of HEV, suggests that current waste management practices may be associated with the dissemination of viruses of public health concern in waters proximal to CAFO spray fields. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Sampling Strategies for Evaluating the Rate of Adventitious Transgene Presence in Non-Genetically Modified Crop Fields.

    PubMed

    Makowski, David; Bancal, Rémi; Bensadoun, Arnaud; Monod, Hervé; Messéan, Antoine

    2017-09-01

    According to E.U. regulations, the maximum allowable rate of adventitious transgene presence in non-genetically modified (GM) crops is 0.9%. We compared four sampling methods for the detection of transgenic material in agricultural non-GM maize fields: random sampling, stratified sampling, random sampling + ratio reweighting, random sampling + regression reweighting. Random sampling involves simply sampling maize grains from different locations selected at random from the field concerned. The stratified and reweighting sampling methods make use of an auxiliary variable corresponding to the output of a gene-flow model (a zero-inflated Poisson model) simulating cross-pollination as a function of wind speed, wind direction, and distance to the closest GM maize field. With the stratified sampling method, an auxiliary variable is used to define several strata with contrasting transgene presence rates, and grains are then sampled at random from each stratum. With the two methods involving reweighting, grains are first sampled at random from various locations within the field, and the observations are then reweighted according to the auxiliary variable. Data collected from three maize fields were used to compare the four sampling methods, and the results were used to determine the extent to which transgene presence rate estimation was improved by the use of stratified and reweighting sampling methods. We found that transgene rate estimates were more accurate and that substantially smaller samples could be used with sampling strategies based on an auxiliary variable derived from a gene-flow model. © 2017 Society for Risk Analysis.

  9. Impact of collection container material and holding times on sample integrity for mercury and methylmercury in water

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riscassi, Ami L; Miller, Carrie L; Brooks, Scott C

    Mercury (Hg) and methylmercury (MeHg) concentrations in streamwater can vary on short timescales (hourly or less) during storm flow and on a diel cycle; the frequency and timing of sampling required to accurately characterize these dynamics may be difficult to accomplish manually. Automated sampling can assist in sample collection; however use has been limited for Hg and MeHg analysis due to stability concerns of trace concentrations during extended storage times. We examined the viability of using automated samplers with disposable low-density polyethylene (LDPE) sample bags to collect industrially contaminated streamwater for unfiltered and filtered Hg and MeHg analysis. Specifically wemore » investigated the effect of holding times ranging from hours to days on streamwater collected during baseflow and storm flow. Unfiltered and filtered Hg and MeHg concentrations decreased with increases in time prior to sample processing; holding times of 24 hours or less resulted in concentration changes (mean 11 7% different) similar to variability in duplicates collected manually during analogous field conditions (mean 7 10% different). Comparisons of samples collected with manual and automated techniques throughout a year for a wide range of stream conditions were also found to be similar to differences observed between duplicate grab samples. These results demonstrate automated sampling into LDPE bags with holding times of 24 hours or less can be effectively used to collect streamwater for Hg and MeHg analysis, and encourage the testing of these materials and methods for implementation in other aqueous systems where high-frequency sampling is warranted.« less

  10. Use of Passive Diffusion Samplers for Monitoring Volatile Organic Compounds in Ground Water

    USGS Publications Warehouse

    Harte, Philip T.; Brayton, Michael J.; Ives, Wayne

    2000-01-01

    Passive diffusion samplers have been tested at a number of sites where volatile organic compounds (VOC's) are the principal contaminants in ground water. Test results generally show good agreement between concentrations of VOC's in samples collected with diffusion samplers and concentrations in samples collected by purging the water from a well. Diffusion samplers offer several advantages over conventional and low-flow ground-water sampling procedures: * Elimination of the need to purge a well before collecting a sample and to dispose of contaminated water. * Elimination of cross-contamination of samples associated with sampling with non-dedicated pumps or sample delivery tubes. * Reduction in sampling time by as much as 80 percent of that required for 'purge type' sampling methods. * An increase in the frequency and spatial coverage of monitoring at a site because of the associated savings in time and money. The successful use of diffusion samplers depends on the following three primary factors: (1) understanding site conditions and contaminants of interest (defining sample objectives), (2) validating of results of diffusion samplers against more widely acknowledged sampling methods, and (3) applying diffusion samplers in the field.

  11. USGS GeoData Digital Raster Graphics

    USGS Publications Warehouse

    ,

    2001-01-01

    Passive diffusion samplers have been tested at a number of sites where volatile organic compounds (VOC?s) are the principal contaminants in ground water. Test results generally show good agreement between concentrations of VOC?s in samples collected with diffusion samplers and concentrations in samples collected by purging the water from a well. Diffusion samplers offer several advantages over conventional and low-flow ground-water sampling procedures: ? Elimination of the need to purge a well before collecting a sample and to dispose of contaminated water. ? Elimination of cross-contamination of samples associated with sampling with non-dedicated pumps or sample delivery tubes. ? Reduction in sampling time by as much as 80 percent of that required for ?purge type? sampling methods. ? An increase in the frequency and spatial coverage of monitoring at a site because of the associated savings in time and money. The successful use of diffusion samplers depends on the following three primary factors: (1) understanding site conditions and contaminants of interest (defining sample objectives), (2) validating of results of diffusion samplers against more widely acknowledged sampling methods, and (3) applying diffusion samplers in the field.

  12. Spent shot availability and ingestion on areas managed for mourning doves

    USGS Publications Warehouse

    Schulz, J.H.; Millspaugh, J.J.; Washburn, B.E.; Wester, G.R.; Lanigan, J. T.; Franson, J.C.

    2002-01-01

    Mourning dove (Zenaida macroura) hunting is becoming increasingly popular, especially in managed shooting fields. Given the possible increase in the availability of lead (Pb) shot on these areas, our objective was to estimate availability and ingestion of spent shot at the Eagle Bluffs Conservation Area (EBCA, hunted with nontoxic shot) and the James A. Reed Memorial Wildlife Area (JARWA, hunted with Pb shot) in Missouri. During 1998, we collected soil samples one or 2 weeks prior to the hunting season (prehunt) and after 4 days of dove hunting (posthunt). We also collected information on number of doves harvested, number of shots fired, shotgun gauge, and shotshell size used. Dove carcasses were collected on both areas during 1998-99. At EBCA, 60 hunters deposited an estimated 64,775 pellets/ha of nontoxic shot on or around the managed field. At JARWA, approximately 1,086,275 pellets/ha of Pb shot were deposited by 728 hunters. Our posthunt estimates of spent-shot availability from soil sampling were 0 pellets/ha for EBCA and 6,342 pellets/ha for JARWA. Our findings suggest that existing soil sampling protocols may not provide accurate estimates of spent-shot availability in managed dove shooting fields. During 1998-99, 15 of 310 (4.8%) mourning doves collected from EBCA had ingested nontoxic shot. Of those doves, 6 (40.0%) contained a?Y7 shot pellets. In comparison, only 2 of 574 (0.3%) doves collected from JARWA had ingested Pb shot. Because a greater proportion of doves ingested multiple steel pellets compared to Pb pellets, we suggest that doves feeding in fields hunted with Pb shot may succumb to acute Pb toxicosis and thus become unavailable to harvest, resulting in an underestimate of ingestion rates. Although further research is needed to test this hypothesis, our findings may partially explain why previous studies have shown few doves with ingested Pb shot despite their feeding on areas with high Pb shot availability.

  13. Exposure of native bees foraging in an agricultural landscape to current-use pesticides.

    PubMed

    Hladik, Michelle L; Vandever, Mark; Smalling, Kelly L

    2016-01-15

    The awareness of insects as pollinators and indicators of environmental quality has grown in recent years, partially in response to declines in honey bee (Apis mellifera) populations. While most pesticide research has focused on honey bees, there has been less work on native bee populations. To determine the exposure of native bees to pesticides, bees were collected from an existing research area in northeastern Colorado in both grasslands (2013-2014) and wheat fields (2014). Traps were deployed bi-monthly during the summer at each land cover type and all bees, regardless of species, were composited as whole samples and analyzed for 136 current-use pesticides and degradates. This reconnaissance approach provides a sampling of all species and represents overall pesticide exposure (internal and external). Nineteen pesticides and degradates were detected in 54 composite samples collected. Compounds detected in >2% of the samples included: insecticides thiamethoxam (46%), bifenthrin (28%), clothianidin (24%), chlorpyrifos (17%), imidacloprid (13%), fipronil desulfinyl (7%; degradate); fungicides azoxystrobin (17%), pyraclostrobin (11%), fluxapyroxad (9%), and propiconazole (9%); herbicides atrazine (19%) and metolachlor (9%). Concentrations ranged from 1 to 310 ng/g for individual pesticides. Pesticides were detected in samples collected from both grasslands and wheat fields; the location of the sample and the surrounding land cover at the 1000 m radius influenced the pesticides detected but because of a small number of temporally comparable samples, correlations between pesticide concentration and land cover were not significant. The results show native bees collected in an agricultural landscape are exposed to multiple pesticides, these results can direct future research on routes/timing of pesticide exposure and the design of future conservation efforts for pollinators. Published by Elsevier B.V.

  14. Strategy to obtain axenic cultures from field-collected samples of the cyanobacterium Phormidium animalis.

    PubMed

    Vázquez-Martínez, Guadalupe; Rodriguez, Mario H; Hernández-Hernández, Fidel; Ibarra, Jorge E

    2004-04-01

    An efficient strategy, based on a combination of procedures, was developed to obtain axenic cultures from field-collected samples of the cyanobacterium Phormidium animalis. Samples were initially cultured in solid ASN-10 medium, and a crude separation of major contaminants from P. animalis filaments was achieved by washing in a series of centrifugations and resuspensions in liquid medium. Then, manageable filament fragments were obtained by probe sonication. Fragmentation was followed by forceful washing, using vacuum-driven filtration through an 8-microm pore size membrane and an excess of water. Washed fragments were cultured and treated with a sequential exposure to four different antibiotics. Finally, axenic cultures were obtained from serial dilutions of treated fragments. Monitoring under microscope examination and by inoculation in Luria-Bertani (LB) agar plates indicated either axenicity or the degree of contamination throughout the strategy.

  15. Rapid, Automated Determination of Elemental Compositions of Ions in Mass Spectra Obtained with an Open-Air Ion Source (2 of 2)

    EPA Science Inventory

    An inexpensive autosampler for a DART/TOFMS provides mass spectra from analytes absorbed on 76 cotton swab, wipe samples in 7.5 min. A field sample carrier simplifies sample collection and provides swabs nearly ready for analysis to the lab. Applications of the high throughput pr...

  16. Hydrogeochemical and stream sediment reconnaissance basic data for Las Cruces quadrangle, New Mexico

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1981-08-31

    Field and laboratory data are presented for 501 water samples and 1817 sediment samples from the Las Cruces Quadrangle, New Mexico. The samples were collected and uranium analysis performed by Los Alamos National Laboratory; multielement analysis and data reporting were performed by the Uranium Resource Evaluation Project at Oak Ridge, Tennessee.

  17. The GSFC Mark-2 three band hand-held radiometer. [thematic mapper for ground truth data collection

    NASA Technical Reports Server (NTRS)

    Tucker, C. J.; Jones, W. H.; Kley, W. A.; Sundstrom, G. J.

    1980-01-01

    A self-contained, portable, hand-radiometer designed for field usage was constructed and tested. The device, consisting of a hand-held probe containing three sensors and a strap supported electronic module, weighs 4 1/2 kilograms. It is powered by flashlight and transistor radio batteries, utilizes two silicon and one lead sulfide detectors, has three liquid crystal displays, sample and hold radiometric sampling, and its spectral configuration corresponds to LANDSAT-D's thematic mapper bands. The device was designed to support thematic mapper ground-truth data collection efforts and to facilitate 'in situ' ground-based remote sensing studies of natural materials. Prototype instruments were extensively tested under laboratory and field conditions with excellent results.

  18. Effect of plot and sample size on timing and precision of urban forest assessments

    Treesearch

    David J. Nowak; Jeffrey T. Walton; Jack C. Stevens; Daniel E. Crane; Robert E. Hoehn

    2008-01-01

    Accurate field data can be used to assess ecosystem services from trees and to improve urban forest management, yet little is known about the optimization of field data collection in the urban environment. Various field and Geographic Information System (GIS) tests were performed to help understand how time costs and precision of tree population estimates change with...

  19. Preliminary results from exploratory sampling of wells for the California oil, gas, and groundwater program, 2014–15

    USGS Publications Warehouse

    McMahon, Peter B.; Kulongoski, Justin T.; Wright, Michael T.; Land, Michael T.; Landon, Matthew K.; Cozzarelli, Isabelle M.; Vengosh, Avner; Aiken, George R.

    2016-08-03

    This report evaluates the utility of the chemical, isotopic, and groundwater-age tracers for assessing sources of salinity, methane, and petroleum hydrocarbons in groundwater overlying or near several California oil fields. Tracers of dissolved organic carbon inoil-field-formation water are also discussed. Tracer data for samples collected from 51 water wells and 4 oil wells are examined.

  20. Preservation of RNA and DNA from mammal samples under field conditions.

    PubMed

    Camacho-Sanchez, Miguel; Burraco, Pablo; Gomez-Mestre, Ivan; Leonard, Jennifer A

    2013-07-01

    Ecological and conservation genetics require sampling of organisms in the wild. Appropriate preservation of the collected samples, usually by cryostorage, is key to the quality of the genetic data obtained. Nevertheless, cryopreservation in the field to ensure RNA and DNA stability is not always possible. We compared several nucleic acid preservation solutions appropriate for field sampling and tested them on rat (Rattus rattus) blood, ear and tail tip, liver, brain and muscle. We compared the efficacy of a nucleic acid preservation (NAP) buffer for DNA preservation against 95% ethanol and Longmire buffer, and for RNA preservation against RNAlater (Qiagen) and Longmire buffer, under simulated field conditions. For DNA, the NAP buffer was slightly better than cryopreservation or 95% ethanol, but high molecular weight DNA was preserved in all conditions. The NAP buffer preserved RNA as well as RNAlater. Liver yielded the best RNA and DNA quantity and quality; thus, liver should be the tissue preferentially collected from euthanized animals. We also show that DNA persists in nonpreserved muscle tissue for at least 1 week at ambient temperature, although degradation is noticeable in a matter of hours. When cryopreservation is not possible, the NAP buffer is an economical alternative for RNA preservation at ambient temperature for at least 2 months and DNA preservation for at least 10 months. © 2013 John Wiley & Sons Ltd.

  1. Artist Material BRDF Database for Computer Graphics Rendering

    NASA Astrophysics Data System (ADS)

    Ashbaugh, Justin C.

    The primary goal of this thesis was to create a physical library of artist material samples. This collection provides necessary data for the development of a gonio-imaging system for use in museums to more accurately document their collections. A sample set was produced consisting of 25 panels and containing nearly 600 unique samples. Selected materials are representative of those commonly used by artists both past and present. These take into account the variability in visual appearance resulting from the materials and application techniques used. Five attributes of variability were identified including medium, color, substrate, application technique and overcoat. Combinations of these attributes were selected based on those commonly observed in museum collections and suggested by surveying experts in the field. For each sample material, image data is collected and used to measure an average bi-directional reflectance distribution function (BRDF). The results are available as a public-domain image and optical database of artist materials at art-si.org. Additionally, the database includes specifications for each sample along with other information useful for computer graphics rendering such as the rectified sample images and normal maps.

  2. MULTIMEDIA CHEMICAL ANALYSIS PLAN FOR CHILDREN'S AGGREGATE EXPOSURE FIELD STUDIES IN NORTH CAROLINA AND OHIO

    EPA Science Inventory

    The samples collected in the CTEPP North Carolina and Ohio field campaigns were analyzed for a suite of organic chemicals in various compound classes, chosen because of their possible carcinogenicity, acute or chronic toxicity, or potential for endocrine system disruption. The...

  3. ENVIRONMENTAL MONITORING AND ASSESSMENT - GREAT RIVER ECOSYSTEMS PROGRAM (EMAP-GRE) GREAT RIVER ECOSYSTEMS FIELD OPERATIONS MANUAL

    EPA Science Inventory

    This manual describes procedures for collecting samples and field measurements for biotic assemblages and abiotic characteristics of the Great Rivers of the Central Basin of the United States: the Missouri, Upper Mississippi, and Ohio Rivers. In addition to the technical and logi...

  4. First report of the spiral nematode Helicotylenchus microlobus infecting soybean in North Dakota

    USDA-ARS?s Scientific Manuscript database

    Spiral nematodes (Helicotylenchus spp.) are common plant-parasitic nematodes in fields of many crops. In June 2015, two soil samples were collected from a soybean field in Richland County, ND. Nematodes were extracted from soil using the sugar centrifugal flotation method. Plant-parasitic nematodes ...

  5. Parasitoids attacking fall armyworm (Lepidoptera: Noctuidae) in sweet corn habitats

    USDA-ARS?s Scientific Manuscript database

    Fall armyworm larvae, Spodoptera frugiperda (J. E. Smith), were collected from sweet corn plants (Zea mays L.) in fields located in three south Florida counties. Fields were sampled from 2010 – 2015 during the fall and spring seasons. Larvae were brought back to the laboratory to complete developme...

  6. Relationship of black vine weevil egg density and damage to two cranberry cultivars

    USDA-ARS?s Scientific Manuscript database

    Field and laboratory trials compared Metarhizium anisopliae and Steinernema kraussei to imidacloprid for black vine weevil (BVW), Otiorhynchus sulcatus, larval control in cranberry. Two field sites were treated in fall of 2009 and soil samples collected during 2009 and 2010 to assess treatment effic...

  7. Using Wireless Power Meters to Measure Energy Use of Miscellaneous and Electronic Devices in Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    UC Berkeley, Berkeley, CA USA; Brown, Richard; Lanzisera, Steven

    2011-05-24

    Miscellaneous and electronic devices consume about one-third of the primary energy used in U.S. buildings, and their energy use is increasing faster than other end-uses. Despite the success of policies, such as Energy Star, that promote more efficient miscellaneous and electronic products, much remains to be done to address the energy use of these devices if we are to achieve our energy and carbon reduction goals. Developing efficiency strategies for these products depends on better data about their actual usage, but very few studies have collected field data on the long-term energy used by a large sample of devices duemore » to the difficulty and expense of collecting device-level energy data. This paper describes the development of an improved method for collecting device-level energy and power data using small, relatively inexpensive wireless power meters. These meters form a mesh network based on Internet standard protocols and can form networks of hundreds of metering points in a single building. Because the meters are relatively inexpensive and do not require manual data downloading, they can be left in the field for months or years to collect long time-series energy use data. In addition to the metering technology, we also describe a field protocol used to collect comprehensive, robust data on the miscellaneous and electronic devices in a building. The paper presents sample results from several case study buildings, in which all the plug-in devices for several homes were metered, and a representative sample of several hundred plug-in devices in a commercial office building were metered for several months.« less

  8. THE NEW YORK CITY URBAN DISPERSION PROGRAM MARCH 2005 FIELD STUDY: TRACER METHODS AND RESULTS.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    WATSON, T.B.; HEISER, J.; KALB, P.

    The Urban Dispersion Program March 2005 Field Study tracer releases, sampling, and analytical methods are described in detail. There were two days where tracer releases and sampling were conducted. A total of 16.0 g of six tracers were released during the first test day or Intensive Observation Period (IOP) 1 and 15.7 g during IOP 2. Three types of sampling instruments were used in this study. Sequential air samplers, or SAS, collected six-minute samples, while Brookhaven atmospheric tracer samplers (BATS) and personal air samplers (PAS) collected thirty-minute samples. There were a total of 1300 samples resulting from the two IOPs.more » Confidence limits in the sampling and analysis method were 20% as determined from 100 duplicate samples. The sample recovery rate was 84%. The integrally averaged 6-minute samples were compared to the 30-minute samples. The agreement was found to be good in most cases. The validity of using a background tracer to calculate sample volumes was examined and also found to have a confidence level of 20%. Methods for improving sampling and analysis are discussed. The data described in this report are available as Excel files. An additional Excel file of quality assured tracer data for use in model validation efforts is also available. The file consists of extensively quality assured BATS tracer data with background concentrations subtracted.« less

  9. Archive of ground penetrating radar data collected during USGS field activity 13BIM01—Dauphin Island, Alabama, April 2013

    USGS Publications Warehouse

    Forde, Arnell S.; Smith, Christopher G.; Reynolds, Billy J.

    2016-03-18

    From April 13 to 20, 2013, scientists from the U.S. Geological Survey St. Petersburg Coastal and Marine Science Center (USGS-SPCMSC) conducted geophysical and sediment sampling surveys on Dauphin Island, Alabama, as part of Field Activity 13BIM01. The objectives of the study were to quantify inorganic and organic accretion rates in back-barrier and mainland marsh and estuarine environments. Various field and laboratory methods were used to achieve these objectives, including subsurface imaging using Ground Penetrating Radar (GPR), sediment sampling, lithologic and microfossil analyses, and geochronology techniques to produce barrier island stratigraphic cross sections to help interpret the recent (last 2000 years) geologic evolution of the island.This data series report is an archive of GPR and associated Global Positioning System (GPS) data collected in April 2013 from Dauphin Island and adjacent barrier-island environments. In addition to GPR data, marsh core and vibracore data were also collected collected but are not reported (or included) in the current report. Data products, including elevation-corrected subsurface profile images of the processed GPR data, unprocessed digital GPR trace data, post-processed GPS data, Geographic Information System (GIS) files and accompanying Federal Geographic Data Committee (FGDC) metadata, can be downloaded from the Data Downloads page.

  10. Analytical results from an environmental investigation of six sites on Kirtland Air Force Base, New Mexico, 1993-94

    USGS Publications Warehouse

    Wilcox, Ralph

    1995-01-01

    The six sites investigated include silver recovery units; a buried caustic drain line; a neutralization pit; an evaporation/infiltration pond; the Manzano fire training area; and a waste oil underground storage tank. Environmental samples of soil, pond sediment, soil gas, and water and gas in floor drains were collected and analyzed. Field quality-control samples were also collected and analyzed in association with the environmental samples. The six sites were investigated because past or current activities could have resulted in contamination of soil, pond sediment, or water and sediment in drains.

  11. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--LIST OF STANDARD OPERATING PROCEDURES

    EPA Science Inventory

    This document lists available protocols and SOPs for the U.S.-Mexico Border Program study. It identifies protocols and SOPs for the following study components: (1) Sample collection and field operations, (2) Sample analysis, (3) General laboratory procedures, (4) Quality Assuranc...

  12. IMPACT OF OIL PRODUCTION RELEASES ON SOME SOIL CHEMICAL PROPERTIES AT THE OSPER SITES

    EPA Science Inventory

    Surface and soil core samples were collected at two field sites in an old oil production area near Skiatook Lake in Oklahoma. The soil samples were analyzed for nitrates, organic matter, total petroleum hydrocarbons, conductivity, chlorides and dehydrogenase activity. Low level...

  13. Enhanced Conformational Sampling Using Replica Exchange with Collective-Variable Tempering.

    PubMed

    Gil-Ley, Alejandro; Bussi, Giovanni

    2015-03-10

    The computational study of conformational transitions in RNA and proteins with atomistic molecular dynamics often requires suitable enhanced sampling techniques. We here introduce a novel method where concurrent metadynamics are integrated in a Hamiltonian replica-exchange scheme. The ladder of replicas is built with different strengths of the bias potential exploiting the tunability of well-tempered metadynamics. Using this method, free-energy barriers of individual collective variables are significantly reduced compared with simple force-field scaling. The introduced methodology is flexible and allows adaptive bias potentials to be self-consistently constructed for a large number of simple collective variables, such as distances and dihedral angles. The method is tested on alanine dipeptide and applied to the difficult problem of conformational sampling in a tetranucleotide.

  14. Guidelines for the processing and quality assurance of benthic invertebrate samples collected as part of the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Cuffney, T.F.; Gurtz, M.E.; Meador, M.R.

    1993-01-01

    Benthic invertebrate samples are collected as part of the U.S. Geological Survey's National Water-Quality Assessment Program. This is a perennial, multidisciplinary program that integrates biological, physical, and chemical indicators of water quality to evaluate status and trends and to develop an understanding of the factors controlling observed water quality. The Program examines water quality in 60 study units (coupled ground- and surface-water systems) that encompass most of the conterminous United States and parts of Alaska and Hawaii. Study-unit teams collect and process qualitative and semi-quantitative invertebrate samples according to standardized procedures. These samples are processed (elutriated and subsampled) in the field to produce as many as four sample components: large-rare, main-body, elutriate, and split. Each sample component is preserved in 10-percent formalin, and two components, large-rare and main-body, are sent to contract laboratories for further processing. The large-rare component is composed of large invertebrates that are removed from the sample matrix during field processing and placed in one or more containers. The main-body sample component consists of the remaining sample materials (sediment, detritus, and invertebrates) and is subsampled in the field to achieve a volume of 750 milliliters or less. The remaining two sample components, elutriate and split, are used for quality-assurance and quality-control purposes. Contract laboratories are used to identify and quantify invertebrates from the large-rare and main-body sample components according to the procedures and guidelines specified within this document. These guidelines allow the use of subsampling techniques to reduce the volume of sample material processed and to facilitate identifications. These processing procedures and techniques may be modified if the modifications provide equal or greater levels of accuracy and precision. The intent of sample processing is to determine the quantity of each taxon present in the semi-quantitative samples or to list the taxa present in qualitative samples. The processing guidelines provide standardized laboratory forms, sample labels, detailed sample processing flow charts, standardized format for electronic data, quality-assurance procedures and checks, sample tracking standards, and target levels for taxonomic determinations. The contract laboratory (1) is responsible for identifications and quantifications, (2) constructs reference collections, (3) provides data in hard copy and electronic forms, (4) follows specified quality-assurance and quality-control procedures, and (5) returns all processed and unprocessed portions of the samples. The U.S. Geological Survey's Quality Management Group maintains a Biological Quality-Assurance Unit, located at the National Water-Quality Laboratory, Arvada, Colorado, to oversee the use of contract laboratories and ensure the quality of data obtained from these laboratories according to the guidelines established in this document. This unit establishes contract specifications, reviews contractor performance (timeliness, accuracy, and consistency), enters data into the National Water Information System-II data base, maintains in-house reference collections, deposits voucher specimens in outside museums, and interacts with taxonomic experts within and outside the U.S. Geological Survey. This unit also modifies the existing sample processing and quality-assurance guidelines, establishes criteria and testing procedures for qualifying potential contract laboratories, identifies qualified taxonomic experts, and establishes voucher collections.

  15. Water-quality data from a sludge disposal test site, St. Petersburg, Florida, November 1973-July 1977

    USGS Publications Warehouse

    Fernandez, Mario

    1978-01-01

    From November 1973 to July 1977, water samples were collected from wells to identify background water-quality conditions and to determine the effects on ground-water quality by St. Petersburg 's sludge-disposal operation (sod farm). Specific conductance and pH were determined in the field. Samples were collected for laboratory determination of selected nitrogen and phosphorus species, sodium, potassium, calcium, magnesium, chloride, trace metals, chemical and biochemical oxygen demand, and coliforms. (Woodard-USGS)

  16. Critical Elements in Produced Fluids from Nevada and Utah

    DOE Data Explorer

    Simmons, Stuart

    2017-07-27

    Critical elements and related analytical data for produced fluids from geothermal fields in Nevada and Utah, Sevier thermal belt hot springs, Utah, and Uinta basin oil-gas wells, Utah are reported. Analytical results include pH, major species, trace elements, transition metals, other metals, metalloids and REEs. Gas samples were collected and analyzed from Beowawe, Dixie Valley, Roosevelt Hot Springs, and Thermo. Helium gases and helium isotopes were analyzed on samples collected at Patua, San Emido and two wells in the Uinta basin.

  17. Evaluation of Trapper-Collected Nobuto Filter-Paper Blood Samples for Distemper and Parvovirus Antibody Detection in Coyotes (Canis latrans) and Raccoons (Procyon lotor).

    PubMed

    Kamps, Amanda J; Dubay, Shelli A; Langenberg, Julie; Maes, Roger K

    2015-07-01

    Blood samples are often collected from free-ranging wildlife for antibody detection. However, filter-paper (FP) strips are more cost efficient and easy to collect and store. We evaluated trapper-collected FP strips and body-cavity blood for canine distemper (CDV) and parvovirus (CPV-2) antibody detection in raccoons (Procyon lotor) and coyotes (Canis latrans). From 2008 to 2010, licensed trappers near Madison and Milwaukee, Wisconsin, US collected paired samples from harvested animals. Canine distemper antibodies were detected using virus neutralization and parvovirus antibodies were detected using hemagglutination inhibition. Titers ≥ 1:32 for CDV and ≥ 1:25 for CPV-2 were considered evidence of exposure. Using Cohen's kappa test of agreement, FP strip titers agreed with sera for CDV in coyotes (n = 28, K = 0.772) and raccoons (n = 29, K = 0.858) and for CPV-2 in coyotes (n = 40, K = 0.775) and raccoons (n = 70, K = 0.646). However, raccoons determined to be exposed to CPV-2 from sera were unexposed by FP strips in 35% of the samples. Titer results may be affected by quality and volume of blood samples, interval between collection and processing, small sample sizes, and diagnostic testing procedures. Filter-paper strips can be useful for detecting CDV and CPV-2 exposure in coyotes and raccoons with correct field sample collection and appropriate diagnostic testing procedures.

  18. NEON Data Products: Supporting the Validation of GCOS Essential Climate Variables

    NASA Astrophysics Data System (ADS)

    Petroy, S. B.; Fox, A. M.; Metzger, S.; Thorpe, A.; Meier, C. L.

    2014-12-01

    The National Ecological Observatory Network (NEON) is a continental-scale ecological observation platform designed to collect and disseminate data that contributes to understanding and forecasting the impacts of climate change, land use change, and invasive species on ecology. NEON will collect in-situ and airborne data over 60 sites across the US, including Alaska, Hawaii, and Puerto Rico. The NEON Biomass, Productivity, and Biogeochemistry protocols currently direct the collection of samples from distributed, gradient, and tower plots at each site, with sampling occurring either multiple times during the growing season, annually, or on three- or five-year centers (e.g. for coarse woody debris). These data are processed into a series of field-derived data products (e.g. Biogeochemistry, LAI, above ground Biomass, etc.), and when combined with the NEON airborne hyperspectral and LiDAR imagery, are used support validation efforts of algorithms for deriving vegetation characteristics from the airborne data. Sites are further characterized using airborne data combined with in-situ tower measurements, to create additional data products of interest to the GCOS community, such as Albedo and fPAR. Presented here are a summary of tower/field/airborne sampling and observation protocols and examples of provisional datasets collected at NEON sites that may be used to support the ongoing validation of GCOS Essential Climate Variables.

  19. Using the FAIMS Mobile App for field data recording

    NASA Astrophysics Data System (ADS)

    Ballsun-Stanton, Brian; Klump, Jens; Ross, Shawn

    2016-04-01

    Multiple people creating data in the field poses a hard technical problem: our ``web 2.0'' environment presumes constant connectivity, data ``authority'' held by centralised servers, and sees mobile devices as tools for presentation rather than origination. A particular design challenge is the remoteness of the sampling locations, hundreds of kilometres away from network access. The alternative, however, is hand collection with a lengthy, error prone, and expensive digitisation process. This poster will present a field-tested open-source solution to field data recording. This solution, originally created by a community of archaeologists, needed to accommodate diverse recording methodologies. The community could not agree on standard vocabularies, workflows, attributes, or methodologies, but most agreed that at app to ``record data in the field'' was desirable. As a result, the app is generalised for field data collection; not only can it record a range of data types, but it is deeply customisable. The NeCTAR / ARC funded FAIMS Project, therefore, created an app which allows for arbitrary data collection in the field. In order to accomplish this ambitious goal, FAIMS relied heavily on OSS projects including: spatialite and gdal (for GIS support), sqlite (for a lightweight key-attribute-value datastore), Javarosa and Beanshell (for UI and scripting), Ruby, and Linux. Only by standing on the shoulders of giants, FAIMS was able to make a flexible and highly generalisable field data collection system that CSIRO geoscientists were able to customise to suit most of their completely unanticipated needs. While single-task apps (i.e. those commissioned by structural geologists to take strikes and dips) will excel in their domains, other geoscientists (palaeoecologists, palaeontologists, anyone taking samples) likely cannot afford to commission domain- and methodology-specific recording tools for their custom recording needs. FAIMS shows the utility of OSS software development and provides geoscientists a way forward for edge-case field data collection. Moreover, as the data is completely open and exports are scriptable, federation with other data services is both possible and encouraged. This poster will describe the internal architecture of the FAIMS app, show how it was used by CSIRO in the field, and display a graph of its OSS heritage. The app is available from Google Play, the recording module can be found at https://github.com/FAIMS/CSIRO-Water-Samples, and the exporter we used can be found at https://github.com/FAIMS/shapefileExport. You can make your own data-collection modules for free via the documentation at https://www.fedarch.org/support/#2. See chapter by Sobotkova et. al. in {Mobilizing the Past}, forthcoming 2016 Ross, S., et. al. (2013) Creating eResearch tools for archaeologists: The federated archaeological information management systems project [online]. {Australian Archaeology}. Ross, S., et. al. (2015). Building the bazaar: enhancing archaeological field recording through an open source approach. In Wilson, A. T., & Edwards, B. (Eds.). {Open Source Archaeology: Ethics and Practice.}. Reid, N., et. al. (2015) {A mobile app for geochemical field data acquisition.} Poster presented at AGU Fall Meeting 2015, San Francisco.

  20. Summary and evaluation of pesticides in field blanks collected for the National Water-Quality Assessment Program, 1992-95

    USGS Publications Warehouse

    Martin, Jeffrey D.; Gilliom, Robert J.; Schertz, Terry L.

    1999-01-01

    Field blanks did show evidence of contamination by some pesticides. Most of the pesticides detected in field blanks, however, were detected more frequently and at higher concentrations in environmental water samples. Two criteria were used to evaluate the need to consider contamination in water-quality assessments: (1) a ratio of the frequency of pesticide detection in environmental water samples to the frequency of detection in field blanks of 5.0 or less and (2) a ratio of the median concentration detected in environmental water samples to the maximum concentration detected in field blanks of 2.0 or less. These criteria indicate that contamination, for the majority of the pesticide data collected for the NAWQA Program, probably does not need to be considered in the analysis and interpretation of (1) the frequency of pesticide detection or (2) the median concentration of pesticides detected. Contamination must be considered, however, in detection frequency for cispermethrin, pronamide, p,p' -DDE, pebulate, propargite, ethalfluralin, and triallate in surface water and fenuron, benfluralin, pronamide, cis-permethrin, triallate, chlorpyrifos, trifluralin, propanil, p,p' -DDE, bromacil, dacthal, diazinon, and diuron in ground water. Contamination also must be considered in median concentrations detected for pronamide, p,p' -DDE, propargite, napropamide, and triallate in surface water and benfluralin, cis-permethrin, triallate, chlorpyrifos, trifluralin, p,p' -DDE, dacthal, and diazinon in ground water.

  1. EPSPS Gene Copy Number and Whole-Plant Glyphosate Resistance Level in Kochia scoparia.

    PubMed

    Gaines, Todd A; Barker, Abigail L; Patterson, Eric L; Westra, Philip; Westra, Eric P; Wilson, Robert G; Jha, Prashant; Kumar, Vipan; Kniss, Andrew R

    2016-01-01

    Glyphosate-resistant (GR) Kochia scoparia has evolved in dryland chemical fallow systems throughout North America and the mechanism of resistance involves 5-enolpyruvylshikimate-3-phosphate synthase (EPSPS) gene duplication. Agricultural fields in four states were surveyed for K. scoparia in 2013 and tested for glyphosate-resistance level and EPSPS gene copy number. Glyphosate resistance was confirmed in K. scoparia populations collected from sugarbeet fields in Colorado, Wyoming, and Nebraska, and Montana. Glyphosate resistance was also confirmed in K. scoparia accessions collected from wheat-fallow fields in Montana. All GR samples had increased EPSPS gene copy number, with median population values up to 11 from sugarbeet fields and up to 13 in Montana wheat-fallow fields. The results indicate that glyphosate susceptibility can be accurately diagnosed using EPSPS gene copy number.

  2. Guidelines for quality assurance and quality control of fish taxonomic data collected as part of the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Walsh, Stephen Joseph; Meador, Michael R.

    1998-01-01

    Fish community structure is characterized by the U.S. Geological Survey's National Water-Quality Assessment (NAWQA) Program as part of a perennial, multidisciplinary approach to evaluating the physical, chemical, and biological conditions of the Nation's water resources. The objective of quality assurance and quality control of fish taxonomic data that are collected as part of the NAWQA Program is to establish uniform guidelines and protocols for the identification, processing, and archiving of fish specimens to ensure that accurate and reliable data are collected. Study unit biologists, collaborating with regional biologists and fish taxonomic specialists, prepare a pre-sampling study plan that includes a preliminary faunal list and identification of an ichthyological curation center for receiving preserved fish specimens. Problematic taxonomic issues and protected taxa also are identified in the study plan, and collecting permits are obtained in advance of sampling activities. Taxonomic specialists are selected to identify fish specimens in the field and to assist in determining what fish specimens should be sacrificed, fixed, and preserved for laboratory identification, independent taxonomic verification, and long-term storage in reference or voucher collections. Quantitative and qualitative sampling of fishes follows standard methods previously established for the NAWQA Program. Common ichthyological techniques are used to process samples in the field and prepare fish specimens to be returned to the laboratory or sent to an institutional repository. Taxonomic identifications are reported by using a standardized list of scientific names that provides nomenclatural consistency and uniformity across study units.

  3. Chemical analysis of whale breath volatiles: a case study for non-invasive field health diagnostics of marine mammals.

    PubMed

    Cumeras, Raquel; Cheung, William H K; Gulland, Frances; Goley, Dawn; Davis, Cristina E

    2014-09-12

    We explored the feasibility of collecting exhaled breath from a moribund gray whale (Eschrichtius robustus) for potential non-invasive health monitoring of marine mammals. Biogenic volatile organic compound (VOC) profiling is a relatively new field of research, in which the chemical composition of breath is used to non-invasively assess the health and physiological processes on-going within an animal or human. In this study, two telescopic sampling poles were designed and tested with the primary aim of collecting whale breath exhalations (WBEs). Once the WBEs were successfully collected, they were immediately transferred onto a stable matrix sorbent through a custom manifold system. A total of two large volume WBEs were successfully captured and pre-concentrated onto two Tenax®-TA traps (one exhalation per trap). The samples were then returned to the laboratory where they were analyzed using solid phase micro extraction (SPME) and gas chromatography/mass spectrometry (GC/MS). A total of 70 chemicals were identified (58 positively identified) in the whale breath samples. These chemicals were also matched against a database of VOCs found in humans, and 44% of chemicals found in the whale breath are also released by healthy humans. The exhaled gray whale breath showed a rich diversity of chemicals, indicating the analysis of whale breath exhalations is a promising new field of research.

  4. Hydrogeochemical and stream sediment reconnaissance basic data for Philip Smith Mountains Quadrangle, Alaska

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1981-05-29

    Field and laboratory data are presented for 1128 water samples from the Philip Smith Mountains Quadrangle, Alaska. The samples were collected by Los Alamos Scientific Laboratory; laboratory analysis and data reporting were performed by the Uranium Resource Evaluation Project at Oak Ridge, Tennessee.

  5. Innovative Ways for Information Transfer in Biobanking

    ERIC Educational Resources Information Center

    Macheiner, Tanja; Huppertz, Berthold; Sargsyan, Karine

    2013-01-01

    Purpose: Biobanks are collections of biological samples (e.g. tissue samples and body fluids) and their associated data intended for various approaches in medical research. The field of biobanking evolves rapidly as an interdisciplinary branch of research and requires educational efforts to provide skilled experts in Europe and beyond. New ways in…

  6. A guide to soil samplng and analysis on the National Forests of the Inland Northwest United States

    Treesearch

    Deb Page-Dumroese; Al Harvey; Marty Jurgensen

    1995-01-01

    This guide details soil collection methods, sample analysis, and data translation. It outlines what field soil scientists need to make accurate interpretations of site information. Included are instructions for sampling typical Andisols found on National Forests of the Inland Northwest United States.

  7. Application of an imputation method for geospatial inventory of forest structural attributes across multiple spatial scales in the Lake States, U.S.A

    NASA Astrophysics Data System (ADS)

    Deo, Ram K.

    Credible spatial information characterizing the structure and site quality of forests is critical to sustainable forest management and planning, especially given the increasing demands and threats to forest products and services. Forest managers and planners are required to evaluate forest conditions over a broad range of scales, contingent on operational or reporting requirements. Traditionally, forest inventory estimates are generated via a design-based approach that involves generalizing sample plot measurements to characterize an unknown population across a larger area of interest. However, field plot measurements are costly and as a consequence spatial coverage is limited. Remote sensing technologies have shown remarkable success in augmenting limited sample plot data to generate stand- and landscape-level spatial predictions of forest inventory attributes. Further enhancement of forest inventory approaches that couple field measurements with cutting edge remotely sensed and geospatial datasets are essential to sustainable forest management. We evaluated a novel Random Forest based k Nearest Neighbors (RF-kNN) imputation approach to couple remote sensing and geospatial data with field inventory collected by different sampling methods to generate forest inventory information across large spatial extents. The forest inventory data collected by the FIA program of US Forest Service was integrated with optical remote sensing and other geospatial datasets to produce biomass distribution maps for a part of the Lake States and species-specific site index maps for the entire Lake State. Targeting small-area application of the state-of-art remote sensing, LiDAR (light detection and ranging) data was integrated with the field data collected by an inexpensive method, called variable plot sampling, in the Ford Forest of Michigan Tech to derive standing volume map in a cost-effective way. The outputs of the RF-kNN imputation were compared with independent validation datasets and extant map products based on different sampling and modeling strategies. The RF-kNN modeling approach was found to be very effective, especially for large-area estimation, and produced results statistically equivalent to the field observations or the estimates derived from secondary data sources. The models are useful to resource managers for operational and strategic purposes.

  8. Comparison of dialysis membrane diffusion samplers and two purging methods in bedrock wells

    USGS Publications Warehouse

    Imbrigiotta, T.E.; Ehlke, T.A.; Lacombe, P.J.; Dale, J.M.; ,

    2002-01-01

    Collection of ground-water samples from bedrock wells using low-flow purging techniques is problematic because of the random spacing, variable hydraulic conductivity, and variable contamination of contributing fractures in each well's open interval. To test alternatives to this purging method, a field comparison of three ground-water-sampling techniques was conducted on wells in fractured bedrock at a site contaminated primarily with volatile organic compounds. Constituent concentrations in samples collected with a diffusion sampler constructed from dialysis membrane material were compared to those in samples collected from the same wells with a standard low-flow purging technique and a hybrid (high-flow/low-flow) purging technique. Concentrations of trichloroethene, cis-1,2-dichloroethene, vinyl chloride, calcium, chloride, and alkalinity agreed well among samples collected with all three techniques in 9 of the 10 wells tested. Iron concentrations varied more than those of the other parameters, but their pattern of variation was not consistent. Overall, the results of nonparametric analysis of variance testing on the nine wells sampled twice showed no statistically significant difference at the 95-percent confidence level among the concentrations of volatile organic compounds or inorganic constituents recovered by use of any of the three sampling techniques.

  9. Hydrogeochemical and stream sediment reconnaissance basic data for Cheyenne Quadrangle, Wyoming

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1981-07-31

    Field and laboratory data are presented for 884 water samples and 598 sediment samples from the Cheyenne Quadrangle, Wyoming. Uranium values have been reported by Los Alamos National Laboratory in Report GJBX-106(78). The samples were collected by Los Alamos National Laboratory; laboratory analysis and data reporting were performed by the Uranium Resource Evaluation Project at Oak Ridge, Tennessee.

  10. Sampling tree tops by helicopter...special pole pruner cuts branchlets

    Treesearch

    John F. Wear; Robert G. Winterfeld

    1966-01-01

    A new technique for sampling tops of tall Douglas-fir trees by using a special pole pruner from a helicopter has been developed and field-tested. Thee pole pruner cuts and holds a branchlet. Foliage samples collected will be compared by spectral analysis to show the type of aerial imagery that best differentiates healthy trees from those attacked by root rot.

  11. Quality of volatile organic compound data from groundwater and surface water for the National Water-Quality Assessment Program, October 1996–December 2008

    USGS Publications Warehouse

    Bender, David A.; Zogorski, John S.; Mueller, David K.; Rose, Donna L.; Martin, Jeffrey D.; Brenner, Cassandra K.

    2011-01-01

    This report describes the quality of volatile organic compound (VOC) data collected from October 1996 to December 2008 from groundwater and surface-water sites for the U.S. Geological Survey's National Water-Quality Assessment (NAWQA) Program. The VOC data described were collected for three NAWQA site types: (1) domestic and public-supply wells, (2) monitoring wells, and (3) surface-water sites. Contamination bias, based on the 90-percent upper confidence limit (UCL) for the 90th percentile of concentrations in field blanks, was determined for VOC samples from the three site types. A way to express this bias is that there is 90-percent confidence that this amount of contamination would be exceeded in no more than 10 percent of all samples (including environmental samples) that were collected, processed, shipped, and analyzed in the same manner as the blank samples. This report also describes how important native water rinsing may be in decreasing carryover contamination, which could be affecting field blanks. The VOCs can be classified into four contamination categories on the basis of the 90-percent upper confidence limit (90-percent UCL) concentration distribution in field blanks. Contamination category 1 includes compounds that were not detected in any field blanks. Contamination category 2 includes VOCs that have a 90-percent UCL concentration distribution in field blanks that is about an order of magnitude lower than the concentration distribution of the environmental samples. Contamination category 3 includes VOCs that have a 90-percent UCL concentration distribution in field blanks that is within an order of magnitude of the distribution in environmental samples. Contamination category 4 includes VOCs that have a 90-percent UCL concentration distribution in field blanks that is at least an order of magnitude larger than the concentration distribution of the environmental samples. Fifty-four of the 87 VOCs analyzed in samples from domestic and public-supply wells were not detected in field blanks (contamination category 1), and 33 VOC were detected in field blanks. Ten of the 33 VOCs had a 90-percent UCL concentration distribution in field blanks that was at least an order of magnitude lower than the concentration distribution in environmental samples (contamination category 2). These 10 VOCs may have had some contamination bias associated with the environmental samples, but the potential contamination bias was negligible in comparison to the environmental data; therefore, the field blanks were assumed to be representative of the sources of contamination bias affecting the environmental samples for these 10 VOCs. Seven VOCs had a 90-percent UCL concentration distribution of the field blanks that was within an order of magnitude of the concentration distribution of the environmental samples (contamination category 3). Sixteen VOCs had a 90-percent UCL concentration distribution in the field blanks that was at least an order of magnitude greater than the concentration distribution of the environmental samples (contamination category 4). Field blanks for these 16 VOCs appear to be nonrepresentative of the sources of contamination bias affecting the environmental samples because of the larger concentration distributions (and sometimes higher frequency of detection) in field blanks than in environmental samples. Forty-three of the 87 VOCs analyzed in samples from monitoring wells were not detected in field blanks (contamination category 1), and 44 VOCs were detected in field blanks. Eight of the 44 VOCs had a 90-percent UCL concentration distribution in field blanks that was at least an order of magnitude lower than concentrations in environmental samples (contamination category 2). These eight VOCs may have had some contamination bias associated with the environmental samples, but the potential contamination bias was negligible in comparison to the environmental data; therefore, the field blanks were assumed to be representative. Seven VOCs had a 90-percent UCL concentration distribution in field blanks that was of the same order of magnitude as the concentration distribution of the environmental samples (contamination category 3). Twenty-nine VOCs had a 90-percent UCL concentration distribution in the field blanks that was an order of magnitude greater than the distribution of the environmental samples (contamination category 4). Field blanks for these 29 VOCs appear to be nonrepresentative of the sources of contamination bias to the environmental samples. Fifty-four of the 87 VOCs analyzed in surface-water samples were not detected in field blanks (category 1), and 33 VOC were detected in field blanks. Sixteen of the 33 VOCs had a 90-percent UCL concentration distribution in field blanks that was at least an order of magnitude lower than the concentration distribution in environmental samples (contamination category 2). These 16 VOCs may have had some contamination bias associated with the environmental samples, but the potential contamination bias was negligible in comparison to the environmental data; therefore, the field blanks were assumed to be representative. Ten VOCs had a 90-percent UCL concentration distribution in field blanks that was similar to the concentration distribution of environmental samples (contamination category 3). Seven VOCs had a 90-percent UCL concentration distribution in the field blanks that was greater than the concentration distribution in environmental samples (contamination category 4). Field-blank samples for these seven VOCs appear to be nonrepresentative of the sources of contamination bias to the environmental samples. The relation between the detection of a compound in field blanks and the detection in subsequent environmental samples appears to be minimal. The median minimum percent effectiveness of native water rinsing is about 79 percent for the 19 VOCs detected in more than 5 percent of field blanks from all three site types. The minimum percent effectiveness of native water rinsing (10 percent) was for toluene in surface-water samples, likely because of the large detection frequency of toluene in surface-water samples (about 79 percent) and in the associated field-blank samples (46.5 percent). The VOCs that were not detected in field blanks (contamination category 1) from the three site types can be considered free of contamination bias, and various interpretations for environmental samples, such as VOC detection frequency at multiple assessment levels and comparisons of concentrations to benchmarks, are not limited for these VOCs. A censoring level for making comparisons at different assessment levels among environmental samples could be applied to concentrations of 9 VOCs in samples from domestic and public-supply wells, 16 VOCs in samples from monitoring wells, and 9 VOCs in surface-water samples to account for potential low-level contamination bias associated with these selected VOCs. Bracketing the potential contamination by comparing the detection and concentration statistics with no censoring applied to the potential for contamination bias on the basis of the 90-percent UCL for the 90th-percentile concentrations in field blanks may be useful when comparisons to benchmarks are done in a study. The VOCs that were not detected in field blanks (contamination category 1) from the three site types can be considered free of contamination bias, and various interpretations for environmental samples, such as VOC detection frequency at multiple assessment levels and comparisons of concentrations to benchmarks, are not limited for these VOCs. A censoring level for making comparisons at different assessment levels among environmental samples could be applied to concentrations of 9 VOCs in samples from domestic and public-supply wells, 16 VOCs in samples from monitoring wells, and 9 VOCs in surface-water samples to account for potential low-level contamination bias associated with these selected VOCs. Bracketing the potential contamination by comparing the detection and concentration statistics with no censoring applied to the potential for contamination bias on the basis of the 90-percent UCL for the 90th-percentile concentrations in field blanks may be useful when comparisons to benchmarks are done in a study.

  12. Providing an Authentic Research Experience for University of the Fraser Valley Undergraduate Students by Investigating and Documenting Seasonal and Longterm Changes in Fraser Valley Stream Water Chemistry.

    NASA Astrophysics Data System (ADS)

    Gillies, S. L.; Marsh, S. J.; Peucker-Ehrenbrink, B.; Janmaat, A.; Bourdages, M.; Paulson, D.; Groeneweg, A.; Bogaerts, P.; Robertson, K.; Clemence, E.; Smith, S.; Yakemchuk, A.; Faber, A.

    2017-12-01

    Undergraduate students in the Geography and Biology Departments at the University of the Fraser Valley (UFV) have been provided the opportunity to participate in the time series sampling of the Fraser River at Fort Langley and Fraser Valley tributaries as part of the Global Rivers Observatory (GRO, www.globalrivers.org) which is coordinated by Woods Hole Oceanographic Institution and Woods Hole Research Center. Student research has focussed on Clayburn, Willband and Stoney Creeks that flow from Sumas Mountain northwards to the Fraser River. These watercourses are increasingly being impacted by anthropogenic activity including residential developments, industrial activity, and agricultural landuse. Students are instructed in field sampling protocols and the collection of water chemistry data and the care and maintenance of the field equipment. Students develop their own research projects and work in support of each other as teams in the field to collect the data and water samples. Students present their findings as research posters at local academic conferences and at UFV's Student Research Day. Through their involvement in our field research our students have become more aware of the state of our local streams, the methods used to monitor water chemistry and how water chemistry varies seasonally.

  13. Authenticity in Teaching: A Constant Process of Becoming

    ERIC Educational Resources Information Center

    Ramezanzadeh, Akram; Zareian, Gholamreza; Adel, Seyyed Mohammad Reza; Ramezanzadeh, Ramin

    2017-01-01

    This study probed the conceptualization of (in)authenticity in teaching and the way it could be enacted in pedagogical practices. The participants were a purposive sample of 20 Iranian university teachers. Data were collected using in-depth interviews, field notes, and observation. The collected data were analyzed through the lens of hermeneutic…

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Broxton, D.E.

    A total of 338 water and 1877 sediment samples were collected over a 20,700-km/sup 2/ area from 2125 locations at a nominal density of one sample per 10 km/sup 2/. Water samples were collected from wells, streams, springs, and artificial ponds. Sediment samples were collected from streams, springs, natural ponds, and artificial ponds. Arbitrary anomaly thresholds of two standard deviations above the mean were chosen for both water and sediment sample populations. The U concentrations in waters collected in the Tularosa quadrangle range from below the detection limit of 0.2 parts per billion (ppB) to 57.8 ppB. Most clusters ofmore » water samples containing anomalously high uranium concentrations were collected from locations in uplifts underlain either by volcanic rocks of the mid-Tertiary Datil group or by sedimentary rocks of late Paleozoic and Mesozoic age. Other groups of anomalous waters are from wells that tap Cenozoic aquifers in the intermontane basins. In those areas where the water-sample location coverage is adequate, the known U occurrences are generally associated with high or anomalous U concentrations in water samples. With the exception of one sample with a U concentration of 67.7 ppM, sediments collected in this study have U concentrations that range between 0.2 and 15.2 ppM. Most sediments with U concentrations above the arbitrary anomaly threshold value are from locations which occur in or parallel outcrops of Precambrian crystalline rock exposed in the San Andres and Oscura Mountains. Other anomalous sediments occur as more discreet groups in areas underlain by mid-Tertiary volcanic rocks of the Datil group. Several anomalous samples from the Mogollon-Datil volcanic field were collected along ring fracture systems that surround large volcanic cauldrons.« less

  15. Feasibility of conducting wetfall chemistry investigations around the Bowen Power Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, N.C.J.; Patrinos, A.A.N.

    1979-10-01

    The feasibility of expanding the Meteorological Effects of Thermal Energy Releases - Oak Ridge National Laboratory (METER-ORNL) research at Bower Power Plant, a coal-fired power plant in northwest Georgia, to include wetfall chemistry is evaluated using results of similar studies around other power plants, several atmospheric washout models, analysis of spatial variability in precipitation, and field logistical considerations. An optimal wetfall chemistry network design is proposed, incorporating the inner portion of the existing rain-gauge network and augmented by additional sites to ensure adequate coverage of probable target areas. The predicted sulfate production rate differs by about four orders of magnitudemore » among the models reviewed with a pH of 3. No model can claim superiority over any other model without substantive data verification. The spatial uniformity in rain amount is evaluated using four storms that occurred at the METER-ORNL network. Values of spatial variability ranged from 8 to 31% and decreased as the mean rainfall increased. The field study of wetfall chemistry will require a minimum of 5 persons to operate the approximately 50 collectors covering an area of 740 km/sup 2/. Preliminary wetfall-only samples collected on an event basis showed lower pH and higher electrical conductivity of precipitation collected about 5 km downwind of the power plant relative to samples collected upwind. Wetfall samples collected on a weekly basis using automatic samplers, however, showed variable results, with no consistent pattern. This suggests the need for event sampling to minimize variable rain volume and multiple-source effects often associated with weekly samples.« less

  16. Deposition Uniformity of Coal Dust on Filters and Its Effect on the Accuracy of FTIR Analyses for Silica.

    PubMed

    Miller, Arthur L; Drake, Pamela L; Murphy, Nathaniel C; Cauda, Emanuele G; LeBouf, Ryan F; Markevicius, Gediminas

    Miners are exposed to silica-bearing dust which can lead to silicosis, a potentially fatal lung disease. Currently, airborne silica is measured by collecting filter samples and sending them to a laboratory for analysis. Since this may take weeks, a field method is needed to inform decisions aimed at reducing exposures. This study investigates a field-portable Fourier transform infrared (FTIR) method for end-of-shift (EOS) measurement of silica on filter samples. Since the method entails localized analyses, spatial uniformity of dust deposition can affect accuracy and repeatability. The study, therefore, assesses the influence of radial deposition uniformity on the accuracy of the method. Using laboratory-generated Minusil and coal dusts and three different types of sampling systems, multiple sets of filter samples were prepared. All samples were collected in pairs to create parallel sets for training and validation. Silica was measured by FTIR at nine locations across the face of each filter and the data analyzed using a multiple regression analysis technique that compared various models for predicting silica mass on the filters using different numbers of "analysis shots." It was shown that deposition uniformity is independent of particle type (kaolin vs. silica), which suggests the role of aerodynamic separation is negligible. Results also reflected the correlation between the location and number of shots versus the predictive accuracy of the models. The coefficient of variation (CV) for the models when predicting mass of validation samples was 4%-51% depending on the number of points analyzed and the type of sampler used, which affected the uniformity of radial deposition on the filters. It was shown that using a single shot at the center of the filter yielded predictivity adequate for a field method, (93% return, CV approximately 15%) for samples collected with 3-piece cassettes.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, B.; Martino, L.

    The White Phosphorus Burning Pits (WPP) Area of Concern (AOC) is a site of about 5.5 acres (2.2 ha) located in the J-Field Study Area, in the Edgewood Area of Aberdeen Proving Ground (APG), Maryland (Figure 1.1). Considerable information about the WPP exists as a result of efforts to characterize the hazards associated with J-Field. Contamination in the J-Field Study Area was first detected during an environmental survey of the APG Edgewood Area conducted in 1977 and 1978 (Nemeth et al. 1983) by the U.S. Army Toxic and Hazardous Materials Agency (USATHAMA; predecessor to the U.S. Army Environmental Center). Asmore » part of a subsequent USATHAMA environmental survey, 11 wells were installed and sampled at J-Field (three of them at the WPP) (Nemeth 1989). Contamination was also detected in 1983 during a munitions disposal survey conducted by Princeton Aqua Science (1984). The Princeton Aqua Science investigation involved installing and sampling nine wells (four at the WPP) and collecting and analyzing surficial and deep composite soil samples (including samples from the WPP area). In 1986, the U.S. Environmental Protection Agency (EPA) issued a Resource Conservation and Recovery Act (RCRA) Permit (MD3-21-002-1355) requiring a post-wide RCRA Facility Assessment (RFA) and a hydrogeologic assessment of J-Field. In 1987, the U.S. Geological Survey (USGS) began a two-phase hydrogeologic assessment in which data were collected to model groundwater flow at J-Field. Soil-gas investigations were conducted, several well clusters were installed (four at the WPP), a groundwater flow model was developed, and groundwater and surface water monitoring programs were established that continue today. The results of the USGS study were published by Hughes (1993).« less

  18. Laying the groundwork for NEON's continental-scale ecological research

    NASA Astrophysics Data System (ADS)

    Dethloff, G.; Denslow, M.

    2013-12-01

    The National Ecological Observatory Network (NEON) is designed to examine a suite of ecological issues. Field-collected data from 96 terrestrial and aquatic sites across the U.S. will be combined with remotely sensed data and existing continental-scale data sets. Field collections will include a range of physical and biological types, including soil, sediment, surface water, groundwater, precipitation, plants, animals, insects, and microbes as well as biological sub-samples such as leaf material, blood and tissue samples, and DNA extracts. Initial data analyses and identifications of approximately 175,000 samples per year will occur at numerous external laboratories when all sites are fully staffed in 2017. Additionally, NEON will archive biotic and abiotic specimens at collections facilities where they will be curated and available for additional analyses by the scientific community. The number of archived specimens is currently estimated to exceed 130,000 per year by 2017. We will detail how NEON is addressing the complexities and challenges around this set of analyses and specimens and how the resulting high-quality data can impact ecological understanding. The raw data returned from external laboratories that is quality checked and served by NEON will be the foundation for many NEON data products. For example, sequence-quality nucleic acids extracted from surface waters, benthic biofilms, and soil samples will be building blocks for data products on microbial diversity. The raw sequence data will also be available for uses such as evolutionary investigations, and the extracts will be archived so others can acquire them for additional research. Currently, NEON is establishing contracts for the analysis and archiving of field-collected samples through 2017. During this period, NEON will gather information on the progress and success of this large-scale effort in order to determine the most effective course to pursue with external facilities. Two areas that NEON already knows to evaluate are the need for geographic expertise in taxonomic identifications and the capacity necessary to handle the volume of samples. NEON is also addressing challenges associated with external entities and the logistics of sample movement, data formatting, data ingestion, and reporting. For example, NEON is considering tools, such as web APIs, which could allow efficient transfer of data from external facilities. Having a standard format in place for that data will be critical to transfer success and quality assessment. NEON is also working on the implementation of quality control measures for diverse analytical and taxonomic processes across laboratories, and is developing an external audit process. Additionally, given NEON's open access approach, the Network is focused on selecting a sample identification protocol that aids in tracking samples with more involved analytical needs and also allows maximum utility for the scientific community. Given the complex nature and breadth of the project, NEON will be developing novel sample management systems as well as metadata schemas. These efforts insure integrity and quality from field to external facility to archive for each sample taken, providing high-quality data now and confidence in future research stemming from raw data generated by NEON and its collection specimens.

  19. A New Paradigm for Tissue Diagnostics: Tools and Techniques to Standardize Tissue Collection, Transport, and Fixation.

    PubMed

    Bauer, Daniel R; Otter, Michael; Chafin, David R

    2018-01-01

    Studying and developing preanalytical tools and technologies for the purpose of obtaining high-quality samples for histological assays is a growing field. Currently, there does not exist a standard practice for collecting, fixing, and monitoring these precious samples. There has been some advancement in standardizing collection for the highest profile tumor types, such as breast, where HER2 testing drives therapeutic decisions. This review examines the area of tissue collection, transport, and monitoring of formalin diffusion and details a prototype system that could be used to help standardize tissue collection efforts. We have surveyed recent primary literature sources and conducted several site visits to understand the most error-prone processes in histology laboratories. This effort identified errors that resulted from sample collection techniques and subsequent transport delays from the operating room (OR) to the histology laboratories. We have therefore devised a prototype sample collection and transport concept. The system consists of a custom data logger and cold transport box and takes advantage of a novel cold + warm (named 2 + 2) fixation method. This review highlights the beneficial aspects of standardizing tissue collection, fixation, and monitoring. In addition, a prototype system is introduced that could help standardize these processes and is compatible with use directly in the OR and from remote sites.

  20. Water-Quality Data for Selected National Park Units within the Southern Colorado Plateau Network, Arizona, Utah, Colorado, and New Mexico, Water Years 2005 and 2006

    USGS Publications Warehouse

    Macy, Jamie P.; Monroe, Stephen A.

    2006-01-01

    The National Park Service initiated a Level 1 Water-Quality Inventory program to provide water-quality data to park managers so informed natural resource management decisions could be made. Level 1 water-quality data were collected by the U.S. Geological Survey Arizona Water Science Center at 57 sites in 13 National Park units located in the Southern Colorado Plateau Inventory and Monitoring network in water years 2005 and 2006. These data describe the current water-quality at selected sites within the park units and provide information for monitoring future trends. Water samples were collected three times at each type of site including wells, springs, seeps, tinajas, rivers, a lake, and an irrigation ditch. Field measurements were taken at each site and they included pH, specific conductance, temperature, barometric pressure, dissolved oxygen, alkalinity, turbidity, and discharge rates where applicable. Water samples collected were sent to the U.S. Geological Survey National Water Quality Laboratory and analyzed for major ions, trace elements, and nutrients. The National Water Quality Laboratory also analyzed selected samples for mercury and petroleum hydrocarbons. Additional samples at selected sites were collected and analyzed for cyanide, radiochemistry, and suspended sediment by U.S. Geological Survey contract labs. Fecal-indicator bacteria (Escherichia coli) were sampled for at selected sites as another indicator of water quality. Quality control for this study was achieved through proper training of field personnel, use of standard U.S. Geological Survey field and laboratory protocols, collection of sample blanks and replicates, and a thorough review of the water-quality analyses. Measured field pH ranged from 6.0 to 8.8, within normal range for springs and rivers, at most sites. Concentrations of dissolved solids ranged from 48 to 8,680 mg/L and the majority of samples had concentrations of dissolved solids below 900 mg/L. Trace-element concentrations at most sites were at or near the laboratory reporting levels. The highest overall trace-element concentrations were found at U.S. Highway 160 Spring near Park Entrance to Mesa Verde National Park. Concentrations of uranium in samples at all sites ranged from below the detection limit to 55.7 ?g/L. Water samples from selected sites were analyzed for total petroleum hydrocarbons and concentrations of total petroleum hydrocarbons were at or above the laboratory detection limit in samples at six National Park units. Ten sites were sampled for Escherichia coli and positive counts were found at 9 out of the ten sites, the highest colony counts were found at Chinle Creek at Chinle, AZ in Canyon de Chelly National Monument. Measured concentrations of dissolved ammonia, nitrite, and nitrate were at or near laboratory reporting levels at most sites; nitrate concentrations ranged from below the reporting limit (0.047 mg/L) to 9.77 mg/L. Samples that were analyzed for mercury had concentrations below or at the laboratory reporting level. Concentrations of cyanide were less than the laboratory reporting level for all samples except two, Spruce Tree House Spring in Mesa Verde National Park and Pine Tree Canyon Tinaja in Canyon de Chelly National Monument, which had average concentrations of .042 and .011 ?g/L respectively. Gross alpha/beta radioactivity counts were below the U.S. Environmental Protection Agency maximum contaminant level except for samples from Casa Chiquita Well Middle at Chaco Culture National Historical Park which averaged 35 pCi/L. Suspended-sediment concentrations were variable and ranged from 10 to 150,000 mg/L.

  1. Evaluation of process errors in bed load sampling using a Dune Model

    USGS Publications Warehouse

    Gomez, Basil; Troutman, Brent M.

    1997-01-01

    Reliable estimates of the streamwide bed load discharge obtained using sampling devices are dependent upon good at-a-point knowledge across the full width of the channel. Using field data and information derived from a model that describes the geometric features of a dune train in terms of a spatial process observed at a fixed point in time, we show that sampling errors decrease as the number of samples collected increases, and the number of traverses of the channel over which the samples are collected increases. It also is preferable that bed load sampling be conducted at a pace which allows a number of bed forms to pass through the sampling cross section. The situations we analyze and simulate pertain to moderate transport conditions in small rivers. In such circumstances, bed load sampling schemes typically should involve four or five traverses of a river, and the collection of 20–40 samples at a rate of five or six samples per hour. By ensuring that spatial and temporal variability in the transport process is accounted for, such a sampling design reduces both random and systematic errors and hence minimizes the total error involved in the sampling process.

  2. Pre-Mission Input Requirements to Enable Successful Sample Collection by A Remote Field/EVA Team

    NASA Technical Reports Server (NTRS)

    Cohen, B. A.; Lim, D. S. S.; Young, K. E.; Brunner, A.; Elphic, R. E.; Horne, A.; Kerrigan, M. C.; Osinski, G. R.; Skok, J. R.; Squyres, S. W.; hide

    2016-01-01

    The FINESSE (Field Investigations to Enable Solar System Science and Exploration) team, part of the Solar System Exploration Virtual Institute (SSERVI), is a field-based research program aimed at generating strategic knowledge in preparation for human and robotic exploration of the Moon, near-Earth asteroids, Phobos and Deimos, and beyond. In contract to other technology-driven NASA analog studies, The FINESSE WCIS activity is science-focused and, moreover, is sampling-focused with the explicit intent to return the best samples for geochronology studies in the laboratory. We used the FINESSE field excursion to the West Clearwater Lake Impact structure (WCIS) as an opportunity to test factors related to sampling decisions. We examined the in situ sample characterization and real-time decision-making process of the astronauts, with a guiding hypothesis that pre-mission training that included detailed background information on the analytical fate of a sample would better enable future astronauts to select samples that would best meet science requirements. We conducted three tests of this hypothesis over several days in the field. Our investigation was designed to document processes, tools and procedures for crew sampling of planetary targets. This was not meant to be a blind, controlled test of crew efficacy, but rather an effort to explicitly recognize the relevant variables that enter into sampling protocol and to be able to develop recommendations for crew and backroom training in future endeavors.

  3. IDENTIFICATION AND QUANTIFICATION OF AEROSOL POLAR OXYGENATED COMPOUNDS BEARING CARBOXYLIC OR HYDROXYL GROUPS. 2. ORGANIC TRACER COMPOUNDS FROM MONOTERPENES

    EPA Science Inventory

    A comparison was made of polar organic compounds found in the field with those produced in secondary organic aerosol from laboratory irradiations of natural hydrocarbons and oxides of nitrogen. The field samples comprised atmospheric particulate matter (PM2.5) collect...

  4. External quality-assurance programs managed by the U.S. Geological Survey in support of the National Atmospheric Deposition Program/National Trends Network

    USGS Publications Warehouse

    Latysh, Natalie E.; Wetherbee, Gregory A.

    2005-01-01

    The U.S. Geological Survey, Branch of Quality Systems, operates the external quality-assurance programs for the National Atmospheric Deposition Program/National Trends Network (NADP/NTN). Beginning in 1978, six different programs have been implemented?the intersite-comparison program, the blind-audit program, the sample-handling evaluation program, the field-audit program, the interlaboratory-comparison program, and the collocated-sampler program. Each program was designed to measure error contributed by specific components in the data-collection process. The intersite-comparison program, which was discontinued in 2004, was designed to assess the accuracy and reliability of field pH and specific-conductance measurements made by site operators. The blind-audit and sample-handling evaluation programs, which also were discontinued in 2002 and 2004, respectively, assessed contamination that may result from sampling equipment and routine handling and processing of the wet-deposition samples. The field-audit program assesses the effects of sample handling, processing, and field exposure. The interlaboratory-comparison program evaluates bias and precision of analytical results produced by the contract laboratory for NADP, the Illinois State Water Survey, Central Analytical Laboratory, and compares its performance with the performance of international laboratories. The collocated-sampler program assesses the overall precision of wet-deposition data collected by NADP/NTN. This report documents historical operations and the operating procedures for each of these external quality-assurance programs. USGS quality-assurance information allows NADP/NTN data users to discern between actual environmental trends and inherent measurement variability.

  5. Field Tests of Real-time In-situ Dissolved CO2 Monitoring for CO2 Leakage Detection in Groundwater

    NASA Astrophysics Data System (ADS)

    Yang, C.; Zou, Y.; Delgado, J.; Guzman, N.; Pinedo, J.

    2016-12-01

    Groundwater monitoring for detecting CO2 leakage relies on groundwater sampling from water wells drilled into aquifers. Usually groundwater samples are required be collected periodically in field and analyzed in the laboratory. Obviously groundwater sampling is labor and cost-intensive for long-term monitoring of large areas. Potential damage and contamination of water samples during the sampling process can degrade accuracy, and intermittent monitoring may miss changes in the geochemical parameters of groundwater, and therefore signs of CO2 leakage. Real-time in-situ monitoring of geochemical parameters with chemical sensors may play an important role for CO2 leakage detection in groundwater at a geological carbon sequestration site. This study presents field demonstration of a real-time in situ monitoring system capable of covering large areas for detection of low levels of dissolved CO2 in groundwater and reliably differentiating natural variations of dissolved CO2 concentration from small changes resulting from leakage. The sand-alone system includes fully distributed fiber optic sensors for carbon dioxide detection with a unique sensor technology developed by Intelligent Optical Systems. The systems were deployed to the two research sites: the Brackenridge Field Laboratory where the aquifer is shallow at depths of 10-20 ft below surface and the Devine site where the aquifer is much deeper at depths of 140 to 150 ft. Groundwater samples were periodically collected from the water wells which were installed with the chemical sensors and further compared to the measurements of the chemical sensors. Our study shows that geochemical monitoring of dissolved CO2 with fiber optic sensors could provide reliable CO2 leakage signal detection in groundwater as long as CO2 leakage signals are stronger than background noises at the monitoring locations.

  6. Stable carbon isotope ratio in atmospheric CO2 collected by new diffusive devices.

    PubMed

    Proto, Antonio; Cucciniello, Raffaele; Rossi, Federico; Motta, Oriana

    2014-02-01

    In this paper, stable carbon isotope ratios (δ (13)C) were determined in the atmosphere by using a Ca-based sorbent, CaO/Ca12Al14O33 75:25 w/w, for passively collecting atmospheric CO2, in both field and laboratory experiments. Field measurements were conducted in three environments characterized by different carbon dioxide sources. In particular, the environments under consideration were a rather heavily trafficked road, where the source of CO2 is mostly vehicle exhaust, a rural unpolluted area, and a private kitchen where the major source of CO2 was gas combustion. Samplers were exposed to the free atmosphere for 3 days in order to allow collection of sufficient CO2 for δ(13)C analysis, then the collected CO2 was desorbed from the adsorbent with acid treatment, and directly analyzed by nondispersive infrared (NDIR) instrument. δ (13)C results confirmed that the samplers collected representative CO2 samples and no fractionation occurred during passive trapping, as also confirmed by an appositely designed experiment conducted in the laboratory. Passive sampling using CaO/Ca12Al14O33 75:25 w/w proved to be an easy and reliable method to collect atmospheric carbon dioxide for δ (13)C analysis in both indoor and outdoor places.

  7. Metazen – metadata capture for metagenomes

    PubMed Central

    2014-01-01

    Background As the impact and prevalence of large-scale metagenomic surveys grow, so does the acute need for more complete and standards compliant metadata. Metadata (data describing data) provides an essential complement to experimental data, helping to answer questions about its source, mode of collection, and reliability. Metadata collection and interpretation have become vital to the genomics and metagenomics communities, but considerable challenges remain, including exchange, curation, and distribution. Currently, tools are available for capturing basic field metadata during sampling, and for storing, updating and viewing it. Unfortunately, these tools are not specifically designed for metagenomic surveys; in particular, they lack the appropriate metadata collection templates, a centralized storage repository, and a unique ID linking system that can be used to easily port complete and compatible metagenomic metadata into widely used assembly and sequence analysis tools. Results Metazen was developed as a comprehensive framework designed to enable metadata capture for metagenomic sequencing projects. Specifically, Metazen provides a rapid, easy-to-use portal to encourage early deposition of project and sample metadata. Conclusions Metazen is an interactive tool that aids users in recording their metadata in a complete and valid format. A defined set of mandatory fields captures vital information, while the option to add fields provides flexibility. PMID:25780508

  8. Metazen - metadata capture for metagenomes.

    PubMed

    Bischof, Jared; Harrison, Travis; Paczian, Tobias; Glass, Elizabeth; Wilke, Andreas; Meyer, Folker

    2014-01-01

    As the impact and prevalence of large-scale metagenomic surveys grow, so does the acute need for more complete and standards compliant metadata. Metadata (data describing data) provides an essential complement to experimental data, helping to answer questions about its source, mode of collection, and reliability. Metadata collection and interpretation have become vital to the genomics and metagenomics communities, but considerable challenges remain, including exchange, curation, and distribution. Currently, tools are available for capturing basic field metadata during sampling, and for storing, updating and viewing it. Unfortunately, these tools are not specifically designed for metagenomic surveys; in particular, they lack the appropriate metadata collection templates, a centralized storage repository, and a unique ID linking system that can be used to easily port complete and compatible metagenomic metadata into widely used assembly and sequence analysis tools. Metazen was developed as a comprehensive framework designed to enable metadata capture for metagenomic sequencing projects. Specifically, Metazen provides a rapid, easy-to-use portal to encourage early deposition of project and sample metadata. Metazen is an interactive tool that aids users in recording their metadata in a complete and valid format. A defined set of mandatory fields captures vital information, while the option to add fields provides flexibility.

  9. Rainfall, discharge, and water-quality data during stormwater monitoring, H-1 storm drain, Oahu, Hawaii, July 1, 2009, to June 30, 2010

    USGS Publications Warehouse

    Presley, Todd K.; Jamison, Marcael T.J.

    2010-01-01

    Storm runoff water-quality samples were collected as part of the State of Hawaii Department of Transportation Stormwater Monitoring Program. The program is designed to assess the effects of highway runoff and urban runoff collected by the H-1 storm drain on the Manoa-Palolo Drainage Canal. This report summarizes rainfall, discharge, and water-quality data collected between July 1, 2009, and June 30, 2010. As part of this program, rainfall and continuous discharge data were collected at the H-1 storm drain. During the year, sampling strategy and sample processing methods were modified to improve the characterization of the effects of discharge from the storm drain on the Manoa-Palolo Drainage Canal. During July 1, 2009, to February 1, 2010, samples were collected from only the H-1 storm drain. Beginning February 2, 2010, samples were collected simultaneously from the H-1 storm drain and the Manoa-Palolo Drainage Canal at a location about 50 feet upstream of the discharge point of the H-1 storm drain. Three storms were sampled during July 1, 2009, to June 30, 2010. All samples were collected using automatic samplers. For the storm of August 12, 2009, grab samples (for oil and grease, and total petroleum hydrocarbons) and a composite sample were collected. The composite sample was analyzed for total suspended solids, nutrients, and selected dissolved and total (filtered and unfiltered) trace metals (cadmium, chromium, nickel, copper, lead, and zinc). Two storms were sampled in March 2010 at the H-1 storm drain and from the Manoa-Palolo Drainage Canal. Two samples were collected during the storm of March 4, 2010, and six samples were collected during the storm of March 8, 2010. These two storms were sampled using the modified strategy, in which discrete samples from the automatic sampler were processed and analyzed individually, rather than as a composite sample, using the simultaneously collected samples from the H-1 storm drain and from the Manoa-Palolo Drainage Canal. The discrete samples were analyzed for some or all of the following constituents: total suspended solids, nutrients, oil and grease, and selected dissolved (filtered) trace metals (cadmium, chromium, nickel, copper, lead, and zinc). Five quality-assurance/quality-control samples were analyzed during the year. These samples included one laboratory-duplicate, one field-duplicate, and one matrix-spike sample prepared and analyzed with the storm samples. In addition, two inorganic blank-water samples, one sample at the H-1 storm drain and one sample at the Manoa-Palolo Drainage Canal, were collected by running the blank water (water purified of all inorganic constituents) through the sampling and processing systems after cleaning automatic sampler lines to verify that the sampling lines were not contaminated.

  10. Sampling for mercury at subnanogram per litre concentrations for load estimation in rivers

    USGS Publications Warehouse

    Colman, J.A.; Breault, R.F.

    2000-01-01

    Estimation of constituent loads in streams requires collection of stream samples that are representative of constituent concentrations, that is, composites of isokinetic multiple verticals collected along a stream transect. An all-Teflon isokinetic sampler (DH-81) cleaned in 75??C, 4 N HCl was tested using blank, split, and replicate samples to assess systematic and random sample contamination by mercury species. Mean mercury concentrations in field-equipment blanks were low: 0.135 ng??L-1 for total mercury (??Hg) and 0.0086 ng??L-1 for monomethyl mercury (MeHg). Mean square errors (MSE) for ??Hg and MeHg duplicate samples collected at eight sampling stations were not statistically different from MSE of samples split in the laboratory, which represent the analytical and splitting error. Low fieldblank concentrations and statistically equal duplicate- and split-sample MSE values indicate that no measurable contamination was occurring during sampling. Standard deviations associated with example mercury load estimations were four to five times larger, on a relative basis, than standard deviations calculated from duplicate samples, indicating that error of the load determination was primarily a function of the loading model used, not of sampling or analytical methods.

  11. User guide for luminescence sampling in archaeological and geological contexts

    USGS Publications Warehouse

    Nelson, Michelle S.; Gray, Harrison J.; Johnson, Jack A.; Rittenour, Tammy M.; Feathers, James K.; Mahan, Shannon

    2015-01-01

    Luminescence dating provides a direct age estimate of the time of last exposure of quartz or feldspar minerals to light or heat and has been successfully applied to deposits, rock surfaces, and fired materials in a number of archaeological and geological settings. Sampling strategies are diverse and can be customized depending on local circumstances, although all sediment samples need to include a light-safe sample and material for dose-rate determination. The accuracy and precision of luminescence dating results are directly related to the type and quality of the material sampled and sample collection methods in the field. Selection of target material for dating should include considerations of adequacy of resetting of the luminescence signal (optical and thermal bleaching), the ability to characterize the radioactive environment surrounding the sample (dose rate), and the lack of evidence for post-depositional mixing (bioturbation in soils and sediment). Sample strategies for collection of samples from sedimentary settings and fired materials are discussed. This paper should be used as a guide for luminescence sampling and is meant to provide essential background information on how to properly collect samples and on the types of materials suitable for luminescence dating.

  12. Enhanced Conformational Sampling Using Replica Exchange with Collective-Variable Tempering

    PubMed Central

    2015-01-01

    The computational study of conformational transitions in RNA and proteins with atomistic molecular dynamics often requires suitable enhanced sampling techniques. We here introduce a novel method where concurrent metadynamics are integrated in a Hamiltonian replica-exchange scheme. The ladder of replicas is built with different strengths of the bias potential exploiting the tunability of well-tempered metadynamics. Using this method, free-energy barriers of individual collective variables are significantly reduced compared with simple force-field scaling. The introduced methodology is flexible and allows adaptive bias potentials to be self-consistently constructed for a large number of simple collective variables, such as distances and dihedral angles. The method is tested on alanine dipeptide and applied to the difficult problem of conformational sampling in a tetranucleotide. PMID:25838811

  13. The Hydrogeochemistry of Qingshui Geothermal Field, Northeastern Taiwan.

    NASA Astrophysics Data System (ADS)

    Yu-Wen, Chen; Cheng-Kuo, Lin; Wayne, Lin; Yu-Te, Chang; Pei-Shan, Hsieh

    2015-04-01

    The Qingshui geothermal field is located at the upstream valley of Lanyang Creek, northeastern Taiwan. It is renowned as a geothermal field. The previous studies demonstrated a higher geothermal gradient, 100oC/km warmer than a normal geotherm. However, Qingshui geothermal field has not been well developed due to the higher mining costs. In the recent years, the Taiwan government has been focusing on developing alternative and renewable energy and initiated a 10 year project, Nation Energy Program. This study is part of this project In general, it is very difficult to collect deep downhole samples without considerable change of hydro- and gas- chemistry of water under high temperature and pressure. A new sampling tool, GTF Sampler, was designed by the research team, Green Energy and Environment Laboratories, Industrial Technology Research Institute. This tool can simultaneously collect high quality geothermal water and gas sample and moreover, the sampling depth can reach up to 800 meters. Accordingly, a more accurate measurements can be conducted in the laboratory. In this study, 10 geothermal samples were collected and measured. The results demonstrate that geothermal water samples are characterized with Na(K)-HCO3 water type and located at the mature water area in Giggenbach Na-K-Mg diagram. Several geothermometers, including silica and cation geothermometry, were used to estimate potential temperature in the geothermal reservoir systems. In general, the geothermoters of Na-K and Na-K-Ca obtain reservoir temperatures between 120-190oC and 130-210oC, respectively, but the silica geothermometer indicates a lower reservoir temperature between 90 and 170oC. There is no big difference among them. It is worth to note that all calculated temperatures are lower than those of in-situ downhole measurements; therefore, more detailed and advanced researches would be needed for the inconsistency. To examine the argument about igneous heat source in the previous studies, rare earth elements (REEs) were also measured in this study. The results normalized by North America Shale REEs (NASC) show a flat pattern and a distinct europium positive anomaly. It possibly indicates a chemical interaction between meteoric water and sedimentary rock, which excludes the possibility of an igneous source.

  14. Water-quality and ground-water-level data, Bernalillo County, central New Mexico, 1995

    USGS Publications Warehouse

    Rankin, D.R.

    1996-01-01

    Water-quality and ground-water-level data were collected in two areas of eastern Bernalillo County in central New Mexico between March and July of 1995. Fifty-one wells, two springs, and the Ojo Grande Acequia in the east mountain area of Bernalillo County and nine wells in the northeast area of the city of Albuquerque were sampled. The water samples were analyzed for selected nutrient species; total organic carbon; major dissolved constituents; dissolved arsenic, boron, iron, and manganese; and methylene blue active substances. Analytical results were used to compute hardness, sodium adsorption ratio, and dissolved solids. Specific conductance, pH, temperature, and alkalinity were measured in the field at the time of sample collection. Ground- water-level and well-depth measurements were made at the time of sample collection when possible. Water-quality data, ground- water-level data, and well-depth data are presented in tabular form.

  15. Geochemical Data from Produced Water Contamination Investigations: Osage-Skiatook Petroleum Environmental Research (OSPER) Sites, Osage County, Oklahoma

    USGS Publications Warehouse

    Thordsen, James J.; Kharaka, Yousif K.; Ambats, Gil; Kakouros, Evangelos; Abbott, Marvin M.

    2007-01-01

    We report chemical and isotopic analyses of 345 water samples collected from the Osage-Skiatook Petroleum Environmental Research (OSPER) project. Water samples were collected as part of an ongoing multi-year USGS investigation to study the transport, fate, natural attenuation, and ecosystem impacts of inorganic salts and organic compounds present in produced water releases at two oil and gas production sites from an aging petroleum field located in Osage County, in northeast Oklahoma. The water samples were collected primarily from monitoring wells and surface waters at the two research sites, OSPER A (legacy site) and OSPER B (active site), during the period March, 2001 to February, 2005. The data include produced water samples taken from seven active oil wells, one coal-bed methane well and two domestic groundwater wells in the vicinity of the OSPER sites.

  16. Time-integrated sampling of fluvial suspended sediment: a simple methodology for small catchments

    NASA Astrophysics Data System (ADS)

    Phillips, J. M.; Russell, M. A.; Walling, D. E.

    2000-10-01

    Fine-grained (<62·5 µm) suspended sediment transport is a key component of the geochemical flux in most fluvial systems. The highly episodic nature of suspended sediment transport imposes a significant constraint on the design of sampling strategies aimed at characterizing the biogeochemical properties of such sediment. A simple sediment sampler, utilizing ambient flow to induce sedimentation by settling, is described. The sampler can be deployed unattended in small streams to collect time-integrated suspended sediment samples. In laboratory tests involving chemically dispersed sediment, the sampler collected a maximum of 71% of the input sample mass. However, under natural conditions, the existence of composite particles or flocs can be expected to increase significantly the trapping efficiency. Field trials confirmed that the particle size composition and total carbon content of the sediment collected by the sampler were representative statistically of the ambient suspended sediment.

  17. Comparison of no-purge and pumped sampling methods for monitoring concentrations of ordnance-related compounds in groundwater, Camp Edwards, Massachusetts Military Reservation, Cape Cod, Massachusetts, 2009-2010

    USGS Publications Warehouse

    Savoie, Jennifer G.; LeBlanc, Denis R.

    2012-01-01

    Field tests were conducted near the Impact Area at Camp Edwards on the Massachusetts Military Reservation, Cape Cod, Massachusetts, to determine the utility of no-purge groundwater sampling for monitoring concentrations of ordnance-related explosive compounds and perchlorate in the sand and gravel aquifer. The no-purge methods included (1) a diffusion sampler constructed of rigid porous polyethylene, (2) a diffusion sampler constructed of regenerated-cellulose membrane, and (3) a tubular grab sampler (bailer) constructed of polyethylene film. In samples from 36 monitoring wells, concentrations of perchlorate (ClO4-), hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX), and octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX), the major contaminants of concern in the Impact Area, in the no-purge samples were compared to concentrations of these compounds in samples collected by low-flow pumped sampling with dedicated bladder pumps. The monitoring wells are constructed of 2- and 2.5-inch-diameter polyvinyl chloride pipe and have approximately 5- to 10-foot-long slotted screens. The no-purge samplers were left in place for 13-64 days to ensure that ambient groundwater flow had flushed the well screen and concentrations in the screen represented water in the adjacent formation. The sampling methods were compared first in six monitoring wells. Concentrations of ClO4-, RDX, and HMX in water samples collected by the three no-purge sampling methods and low-flow pumped sampling were in close agreement for all six monitoring wells. There is no evidence of a systematic bias in the concentration differences among the methods on the basis of type of sampling device, type of contaminant, or order in which the no-purge samplers were tested. A subsequent examination of vertical variations in concentrations of ClO4- in the 10-foot-long screens of six wells by using rigid porous polyethylene diffusion samplers indicated that concentrations in a given well varied by less than 15 percent and the small variations were unlikely to affect the utility of the various sampling methods. The grab sampler was selected for additional tests in 29 of the 36 monitoring wells used during the study. Concentrations of ClO4-, RDX, HMX, and other minor explosive compounds in water samples collected by using a 1-liter grab sampler and low-flow pumped sampling were in close agreement in field tests in the 29 wells. A statistical analysis based on the sign test indicated that there was no bias in the concentration differences between the methods. There also was no evidence for a systematic bias in concentration differences between the methods related to location of the monitoring wells laterally or vertically in the groundwater-flow system. Field tests in five wells also demonstrated that sample collection by using a 2-liter grab sampler and sequential bailing with the 1-liter grab sampler were options for obtaining sufficient sample volume for replicate and spiked quality assurance and control samples. The evidence from the field tests supports the conclusion that diffusion sampling with the rigid porous polyethylene and regenerated-cellulose membranes and grab sampling with the polyethylene-film samplers provide comparable data on the concentrations of ordnance-related compounds in groundwater at the MMR to that obtained by low-flow pumped sampling. These sampling methods are useful methods for monitoring these compounds at the MMR and in similar hydrogeologic environments.

  18. Aqueous geochemical data from the analysis of stream water samples collected in August 2004--Taylor Mountains 1:250,000 scale Quadrangle, Alaska

    USGS Publications Warehouse

    Wang, Bronwen; Mueller, Seth; Bailey, Elizabeth; Lee, Greg

    2006-01-01

    We report on the chemical analysis of water samples collected from the Taylor Mountains 1:250,000 quadrangle. Samples were collected as part of the multi-year U.S. Geological Survey's project -- Geologic and Mineral Deposit Data for Alaskan Economic Development. Data presented here are from water samples collected primarily in the northeastern part of the Taylor Mountains quadrangle. The data include samples taken from the Taylor Mountains C1, C2, D1, D2, and D4 1:63,360 scale quadrangles. The data are being released at this time with minimal interpretation. Site selection was based on a regional sampling strategy that focused on first and second order drainages. Water sampling site selection was based on landscape parameters that included physiography, wetland extent, lithological changes, and the cursory field review of the mineralogy from the pan concentrates. Stream water in the Taylor Mountians quadrangle is dominated by bicarbonate (HCO3-), though in a few samples more than 50% of the anionic charge can be attibuted to sulfate ( SO42-). The major-cation chemistry range from Ca/Mg dominated to a mix of Ca/Mg/Na+K. Good agreement was found between the major cation and anions in the duplicate samples. Many trace elements were at or near the method detection limit in these samples but good agreement was found between duplicate samples for elements with detectable concentrations. Major ion concentrations were below detection in all field blanks and the trace elements concentrations generally were below detection. However, Ta (range 0.9 -.1 ug/L) and Zn (1 to 3.5 ug/L) were detected in all blanks and Ba ( 0.24 ug/L) and Th (0.2 ug/L) were detected in one blank. There was good agreement between dupilicate total- and methyl- mercury and DOC samples; however, total mercury, methyl-mercury and dissolve organic carbon (DOC) were detected in the blank at 2.35 ng/L, 0.07 ng/L and 0.57 mg/L, respectively.

  19. Collection of Pyrethroids in Water and Sediment Matrices: Development and Validation of a Standard Operating Procedure

    USGS Publications Warehouse

    Hladik, Michelle; Orlando, James L.; Kuivila, Kathryn

    2009-01-01

    Loss of pyrethroid insecticides onto surfaces during sample collection can confound the interpretation of analytical and toxicity test results. Sample collection devices, container materials, and water matrix composition have a significant influence on the association of pyrethroids to container walls, which can be as high as 50 percent. Any sample collection method involving transfer through multiple containers or pieces of equipment increases the potential for pyrethroid loss. This loose 'surface-association' with container walls can be reversed through agitation. When sampling water matrices with pumps or autosamplers, no pyrethroids were lost as long as the water was moving continuously through the system. When collecting water matrices in containers, the material with the least amount of pyrethroid sorption is as follows: glass less than (<) plastic less than (<) Teflon. Additionally, pyrethroids were easier to re-suspend from the glass container walls. Since the amount of surface-association is proportional to the ratio of volume-to-contact-area of the sample, taking larger-volume field samples (greater than 3 liters) reduced pyrethroid losses to less than 10 percent. The amount of surface-association cannot be predicted easily because of the dependence on water matrix composition; samples with higher dissolved organic carbon or suspended-sediment concentrations were observed to have lower percent loss. Sediment samples were not affected by glass-container sorption (the only containers tested). Standardized sample-collection protocols are critical to yield accurate pyrethroid concentrations for assessment of potential effects, and have been summarized in an accompanying standard operating procedure.

  20. Organophosphorus and carbamate pesticide residues detected in water samples collected from paddy and vegetable fields of the Savar and Dhamrai Upazilas in Bangladesh.

    PubMed

    Chowdhury, Md Alamgir Zaman; Banik, Sanjoy; Uddin, Borhan; Moniruzzaman, Mohammed; Karim, Nurul; Gan, Siew Hua

    2012-09-11

    Several types of organophosphorous and carbamate pesticides have been used extensively by the farmers in Bangladesh during the last few decades. Twenty seven water samples collected from both paddy and vegetable fields in the Savar and Dhamrai Upazilas in Bangladesh were analyzed to determine the occurrence and distribution of organo-phosphorus (chlorpyrifos, malathion and diazinon) and carbamate (carbaryl and carbofuran) pesticide residues. A high performance liquid chromatograph instrument equipped with a photodiode array detector was used to determine the concentrations of these pesticide residues. Diazinon and carbofuran were detected in water samples collected from Savar Upazila at 0.9 μg/L and 198.7 μg/L, respectively. Malathion was also detected in a single water sample at 105.2 μg/L from Dhamrai Upazila. Carbaryl was the most common pesticide detected in Dhamrai Upazila at 14.1 and 18.1 μg/L, while another water sample from Dhamrai Upazila was contaminated with carbofuran at 105.2 μg/L. Chlorpyrifos was not detected in any sample. Overall, the pesticide residues detected were well above the maximum acceptable levels of total and individual pesticide contamination, at 0.5 and 0.1 μg/L, respectively, in water samples recommended by the European Economic Community (Directive 98/83/EC). The presence of these pesticide residues may be attributed by their intense use by the farmers living in these areas. Proper handling of these pesticides should be ensured to avoid direct or indirect exposure to these pesticides.

  1. Association of insects and ergot (Claviceps purpurea) in Kentucky bluegrass seed production fields.

    PubMed

    Butler, M D; Alderman, S C; Hammond, P C; Berry, R E

    2001-12-01

    Insects in Kentucky bluegrass seed production fields in Oregon, Idaho, and Washington were sampled just before harvest and their association with ergot conidia of Claviceps purpurea Fr. (Tul.) was evaluated during 1996-1998. A diversity of insects was observed at all three locations. The most abundant beneficial insects collected with sweep nets were Nysium spp., Nabis spp., ichneumonid wasps, and Hippodamia spp. The cranberry girdler, Chrysoteuchia topiaria (Zeller), was the only important pest on grass seed collected by sweep net. Numbers of aphids such as Sitobion avenae (F.), cicadellids and thrips such as Anaphothrips spp. and Aptinothrips spp. that were collected with all aphid sampler were below economic thresholds. Other insect groups occurred in low numbers. Noctuid moths collected in universal blacklight traps included nine species of cutworms and armyworms. Protogrotis obscura (B. & McD.) was the most common cutworm species and was present in all fields. The moth Chortodes rufostrigata (Pack.) previously reported only from wet meadows in northeast and south central Oregon was found in Kentucky bluegrass fields in central Oregon, suggesting that irrigated Kentucky bluegrass seed production fields may simulate a montane meadow habitat. Conidia of C. purpurea were found on a diversity of insects, including moths, flies, leafhoppers, and thrips. Up to 100% of moths and 75% of flies collected from some fields carried conidia of C. purpurea. No correlation between ergot honeydew present in a field and number of insects with conidia of C. purpurea was detected.

  2. Trace gas measurements from whole air samples collected over the Antarctic continent

    NASA Technical Reports Server (NTRS)

    Heidt, L. E.; Vedder, J. F.; Pollock, Walter H.; Henry, Bruce E.; Lueb, Richard A.

    1988-01-01

    Whole air samples collected aboard the NASA DC-8 and ER-2 aircraft as part of the Airborne Antarctic Ozone Experiment (AAOE) were analyzed in a field laboratory set up at Punta Arenas, Chile, in August and September, 1987. Mixing ratios obtained from gas chromatographic analyses of these samples are presented for N2O, CFCl3, CFCl2, C2F3Cl3, CH3CCl3, CH4, and CO. Variations in the mixing ratios of these gases along the individual flight paths of the aircraft are used as tracers to indicate the history of air masses over and near the Antarctic continent.

  3. Rainfall-runoff of anthropogenic waste indicators from agricultural fields applied with municipal biosolids.

    PubMed

    Gray, James L; Borch, Thomas; Furlong, Edward T; Davis, Jessica G; Yager, Tracy J; Yang, Yun-Ya; Kolpin, Dana W

    2017-02-15

    The presence of anthropogenic contaminants such as antimicrobials, flame-retardants, and plasticizers in runoff from agricultural fields applied with municipal biosolids may pose a potential threat to the environment. This study assesses the potential for rainfall-induced runoff of 69 anthropogenic waste indicators (AWIs), widely found in household and industrial products, from biosolids amended field plots. The agricultural field containing the test plots was treated with biosolids for the first time immediately prior to this study. AWIs present in soil and biosolids were isolated by continuous liquid-liquid extraction and analyzed by full-scan gas chromatography/mass spectrometry. Results for 18 AWIs were not evaluated due to their presence in field blank QC samples, and another 34 did not have sufficient detection frequency in samples to analyze trends in data. A total of 17 AWIs, including 4-nonylphenol, triclosan, and tris(2-butoxyethyl)phosphate, were present in runoff with acceptable data quality and frequency for subsequent interpretation. Runoff samples were collected 5days prior to and 1, 9, and 35days after biosolids application. Of the 17 AWIs considered, 14 were not detected in pre-application samples, or their concentrations were much smaller than in the sample collected one day after application. A range of trends was observed for individual AWI concentrations (typically from 0.1 to 10μg/L) over the course of the study, depending on the combination of partitioning and degradation mechanisms affecting each compound most strongly. Overall, these results indicate that rainfall can mobilize anthropogenic contaminants from biosolids-amended agricultural fields, directly to surface waters and redistribute them to terrestrial sites away from the point of application via runoff. For 14 of 17 compounds examined, the potential for runoff remobilization during rainstorms persists even after three 100-year rainstorm-equivalent simulations and the passage of a month. Copyright © 2016. Published by Elsevier B.V.

  4. Rainfall-runoff of anthropogenic waste indicators from agricultural fields applied with municipal biosolids

    USGS Publications Warehouse

    Gray, James L.; Borch, Thomas; Furlong, Edward T.; Davis, Jessica; Yager, Tracy; Yang, Yun-Ya; Kolpin, Dana W.

    2017-01-01

    The presence of anthropogenic contaminants such as antimicrobials, flame-retardants, and plasticizers in runoff from agricultural fields applied with municipal biosolids may pose a potential threat to the environment. This study assesses the potential for rainfall-induced runoff of 69 anthropogenic waste indicators (AWIs), widely found in household and industrial products, from biosolids amended field plots. The agricultural field containing the test plots was treated with biosolids for the first time immediately prior to this study. AWIs present in soil and biosolids were isolated by continuous liquid-liquid extraction and analyzed by full-scan gas chromatography/mass spectrometry. Results for 18 AWIs were not evaluated due to their presence in field blank QC samples, and another 34 did not have sufficient detection frequency in samples to analyze trends in data. A total of 17 AWIs, including 4-nonylphenol, triclosan, and tris(2-butoxyethyl)phosphate, were present in runoff with acceptable data quality and frequency for subsequent interpretation. Runoff samples were collected 5 days prior to and 1, 9, and 35 days after biosolids application. Of the 17 AWIs considered, 14 were not detected in pre-application samples, or their concentrations were much smaller than in the sample collected one day after application. A range of trends was observed for individual AWI concentrations (typically from 0.1 to 10 μg/L) over the course of the study, depending on the combination of partitioning and degradation mechanisms affecting each compound most strongly. Overall, these results indicate that rainfall can mobilize anthropogenic contaminants from biosolids-amended agricultural fields, directly to surface waters and redistribute them to terrestrial sites away from the point of application via runoff. For 14 of 17 compounds examined, the potential for runoff remobilization during rainstorms persists even after three 100-year rainstorm-equivalent simulations and the passage of a month.

  5. Water-quality and biological data for selected streams, lakes, and wells in the High Point Lake watershed, Guilford County, North Carolina, 1988-89

    USGS Publications Warehouse

    Davenport, M.S.

    1993-01-01

    Water and bottom-sediment samples were collected at 26 sites in the 65-square-mile High Point Lake watershed area of Guilford County, North Carolina, from December 1988 through December 1989. Sampling locations included 10 stream sites, 8 lake sites, and 8 ground-water sites. Generally, six steady-flow samples were collected at each stream site and three storm samples were collected at five sites. Four lake samples and eight ground-water samples also were collected. Chemical analyses of stream and lake sediments and particle-size analyses of lake sediments were performed once during the study. Most stream and lake samples were analyzed for field characteristics, nutrients, major ions, trace elements, total organic carbon, and chemical-oxygen demand. Analyses were performed to detect concentrations of 149 selected organic compounds, including acid and base/neutral extractable and volatile constituents and carbamate, chlorophenoxy acid, triazine, organochlorine, and organophosphorus pesticides and herbicides. Selected lake samples were analyzed for all constituents listed in the Safe Drinking Water Act of 1986, including Giardia, Legionella, radiochemicals, asbestos, and viruses. Various chromatograms from organic analyses were submitted to computerized library searches. The results of these and all other analyses presented in this report are in tabular form.

  6. Bridging the gap between sample collection and laboratory analysis: using dried blood spots to identify human exposure to chemical agents

    NASA Astrophysics Data System (ADS)

    Hamelin, Elizabeth I.; Blake, Thomas A.; Perez, Jonas W.; Crow, Brian S.; Shaner, Rebecca L.; Coleman, Rebecca M.; Johnson, Rudolph C.

    2016-05-01

    Public health response to large scale chemical emergencies presents logistical challenges for sample collection, transport, and analysis. Diagnostic methods used to identify and determine exposure to chemical warfare agents, toxins, and poisons traditionally involve blood collection by phlebotomists, cold transport of biomedical samples, and costly sample preparation techniques. Use of dried blood spots, which consist of dried blood on an FDA-approved substrate, can increase analyte stability, decrease infection hazard for those handling samples, greatly reduce the cost of shipping/storing samples by removing the need for refrigeration and cold chain transportation, and be self-prepared by potentially exposed individuals using a simple finger prick and blood spot compatible paper. Our laboratory has developed clinical assays to detect human exposures to nerve agents through the analysis of specific protein adducts and metabolites, for which a simple extraction from a dried blood spot is sufficient for removing matrix interferents and attaining sensitivities on par with traditional sampling methods. The use of dried blood spots can bridge the gap between the laboratory and the field allowing for large scale sample collection with minimal impact on hospital resources while maintaining sensitivity, specificity, traceability, and quality requirements for both clinical and forensic applications.

  7. Solid phase microextraction field kit

    DOEpatents

    Nunes, Peter J.; Andresen, Brian D.

    2005-08-16

    A field kit for the collection, isolation and concentration of trace amounts of high explosives (HE), biological weapons (BW) and chemical weapons (CW) residues in air, soil, vegetation, swipe, and liquid samples. The field kit includes a number of Solid Phase Microextraction (SPME) fiber and syringe assemblies in a hermetically sealed transportation container or tubes which includes a sampling port, a number of extra SPME fiber and syringe assemblies, the fiber and syringe assemblies including a protective cap for the fiber, and an extractor for the protective cap, along with other items including spare parts, protective glove, and an instruction manual, all located in an airtight container.

  8. Mass rearing of Lucilia sericata Meigen (Diptera: Calliphoridae)

    PubMed Central

    Firoozfar, F; Moosa-Kazemi, H; Baniardalani, M; Abolhassani, M; Khoobdel, M; Rafinejd, J

    2011-01-01

    Objective To carry out an experimental study with the main objective of mass rearing of sheep flies (Lucilia sericata). Methods Hand collection and beef- or cattle liver-baited net traps were used for field fly sampling from April, 2010 to November, 2010. The samples collected from different places were placed in properly labeled tubes and sent to the Entomology Laboratory. Since maggot identification is important in inducing mortality, they were kept under insectary condition to develop to adult stage and identified using systematic keys. Results A total of 218 flies were collected in three rounds of sampling from the field of Tehran and Karaj Counties. In the first generation, 433 flies including 135 (31.17%) male, and 298 (68.82%) female were yielded. The female/male of parent ratio was calculated as 1.72 in Tehran and in Karaj areas, whereas it was 2.20% and 1.81%, respectively in F1 and F2 generations, respectively. Conclusions During this study, the mass rearing of sheep blow fly has been established at the School of Public Health, Tehran University of Medical Sciences and can be used for producing flies for maggot therapy. PMID:23569725

  9. Hydrogeochemical and stream sediment reconnaissance basic data for Aztec Quadrangle, New Mexico

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1981-07-31

    Field and laboratory data are presented for 331 water samples and 1693 sediment samples from the Aztec Quadrangle, New Mexico. Uranium values have been reported by Los Alamos National Laboratory in Report GJBX-129(78). The samples were collected by Los Alamos National Laboratory; laboratory analysis and data reporting were performed by the Uranium Resource Evaluation Project at Oak Ridge, Tennessee.

  10. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR PREPARATION OF FILTERS AND PUF FOR FIELD COLLECTION OF METALS AND PESTICIDES IN AIR (BCO-L-2.0)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for pre-cleaning filters and polyurethane foam (PUF) plug prior to air sampling with these media. The sampling media are used for sampling indoor air, outdoor air, and personal air. This procedure was followed to ensure consi...

  11. High-frequency, long-duration water sampling in acid mine drainage studies: a short review of current methods and recent advances in automated water samplers

    USGS Publications Warehouse

    Chapin, Thomas

    2015-01-01

    Hand-collected grab samples are the most common water sampling method but using grab sampling to monitor temporally variable aquatic processes such as diel metal cycling or episodic events is rarely feasible or cost-effective. Currently available automated samplers are a proven, widely used technology and typically collect up to 24 samples during a deployment. However, these automated samplers are not well suited for long-term sampling in remote areas or in freezing conditions. There is a critical need for low-cost, long-duration, high-frequency water sampling technology to improve our understanding of the geochemical response to temporally variable processes. This review article will examine recent developments in automated water sampler technology and utilize selected field data from acid mine drainage studies to illustrate the utility of high-frequency, long-duration water sampling.

  12. Status of SRNL radiological field lysimeter experiment-Year 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kaplan, D.; Roberts, K.; Bagwell, L.

    The Savannah River National Laboratory (SRNL) Radiological Field Lysimeter Experiment is a one-of-a-kind field facility designed to study radionuclide geochemical processes at a larger spatial scale (from grams to tens of kilograms sediment) and temporal scale (from months to 10 years) than is readily afforded through laboratory studies. The lysimeter facility is intended to capture the natural heterogeneity of moisture and temperature regimes in the vadose zone, the unsaturated subsurface region between the surface soil and the underlying aquifer. The 48 lysimeter columns, which contain various radionuclides (and stable iodine), were opened to rainfall infiltration on July 5, 2012. Themore » objective of this report is to provide a status of the lysimeter facility operations and to compile data collected during FY13, including leachate volume, rainfall, and soil moisture and temperature in situ probe data. Radiological leachate data are not presented in this document but will be the subject of a separate document.1 Leachate samples were collected quarterly and shipped to Clemson University for radiological analyses. Rainfall, leachate volume, moisture and temperature probe data were collected continuously. During operations of the facility this year, there were four safety or technical concerns that required additional maintenance: 1) radioactivity was detected in one of the overflow bottles (captured water collected from the secondary containment that does not come in contact with the radiological source material); 2) rainwater accumulated within the sample-bottle storage sheds; 3) overflow containers collected more liquid than anticipated; and 4) significant spider infestation occurred in the sample-bottle storage sheds. To address the first three concerns, each of the lysimeter columns was re-plumbed to improve and to minimize the number of joint unions. To address the fourth concern regarding spiders, new sample-bottle water sheds were purchased and a pest control program was established. During this retrofit, the lysimeters were temporarily capped (covered to preclude additional water from entering lysimeter columns) for about two months (except the four Tc-cementitious containing lysimeters, which remain capped). At a later date, data summarized in this report will be combined with the leachate radionuclide concentration data that are presently being analyzed. Together, these data can be numerically modeled to provide bench-marking information, to test hypotheses regarding hydrogeochemical conceptual models, and to estimate effective transport parameters under field conditions.« less

  13. First Report of the new root-lesion nematode Pratylenchus sp. on soybean in North Dakota

    USDA-ARS?s Scientific Manuscript database

    Root-lesion nematodes (Pratylenchus spp.) are important nematode pests on soybean. In 2015, two soil samples were collected from a soybean field in Richland County, ND. Nematodes were extracted from soil using a sugar centrifugal flotation method, revealing these two samples contained 125 and 350 ro...

  14. Selected Characteristics of Persons in Environmental Science: 1978.

    ERIC Educational Resources Information Center

    Palumbo, Thomas J.; And Others

    1982-01-01

    This report is the third of a series of reports based on data collected in the 1978 National Sample of Scientists and Engineers survey. Profiled are the characteristics of 29,775 persons represented in the national sample's field of environmental scientists: 24,615 earth scientists, 3,481 atmospheric scientists, and 1,678 oceanographers.…

  15. QUALITY SYSTEMS AND IMPLEMENTATION PLAN FOR A PILOT STUDY OF CHILDREN'S TOTAL EXPOSURE TO PERSISTENT PESTICIDES AND OTHER PERSISTENT ORGANIC PESTICIDES (CTEPP)

    EPA Science Inventory

    The Quality System Implementation Plan (QSIP) describes the quality assurance and quality control procedures developed for the CTEPP study. It provides the QA/QC procedures used in recruitment of subjects, sample field collection, sample extraction and analysis, data storage, and...

  16. EPSPS Gene Copy Number and Whole-Plant Glyphosate Resistance Level in Kochia scoparia

    PubMed Central

    Gaines, Todd A.; Barker, Abigail L.; Patterson, Eric L.; Westra, Philip; Westra, Eric P.; Wilson, Robert G.; Jha, Prashant; Kumar, Vipan

    2016-01-01

    Glyphosate-resistant (GR) Kochia scoparia has evolved in dryland chemical fallow systems throughout North America and the mechanism of resistance involves 5-enolpyruvylshikimate-3-phosphate synthase (EPSPS) gene duplication. Agricultural fields in four states were surveyed for K. scoparia in 2013 and tested for glyphosate-resistance level and EPSPS gene copy number. Glyphosate resistance was confirmed in K. scoparia populations collected from sugarbeet fields in Colorado, Wyoming, and Nebraska, and Montana. Glyphosate resistance was also confirmed in K. scoparia accessions collected from wheat-fallow fields in Montana. All GR samples had increased EPSPS gene copy number, with median population values up to 11 from sugarbeet fields and up to 13 in Montana wheat-fallow fields. The results indicate that glyphosate susceptibility can be accurately diagnosed using EPSPS gene copy number. PMID:27992501

  17. Integrated field lysimetry and porewater sampling for evaluation of chemical mobility in soils and established vegetation.

    PubMed

    Matteson, Audrey R; Mahoney, Denis J; Gannon, Travis W; Polizzotto, Matthew L

    2014-07-04

    Potentially toxic chemicals are routinely applied to land to meet growing demands on waste management and food production, but the fate of these chemicals is often not well understood. Here we demonstrate an integrated field lysimetry and porewater sampling method for evaluating the mobility of chemicals applied to soils and established vegetation. Lysimeters, open columns made of metal or plastic, are driven into bareground or vegetated soils. Porewater samplers, which are commercially available and use vacuum to collect percolating soil water, are installed at predetermined depths within the lysimeters. At prearranged times following chemical application to experimental plots, porewater is collected, and lysimeters, containing soil and vegetation, are exhumed. By analyzing chemical concentrations in the lysimeter soil, vegetation, and porewater, downward leaching rates, soil retention capacities, and plant uptake for the chemical of interest may be quantified. Because field lysimetry and porewater sampling are conducted under natural environmental conditions and with minimal soil disturbance, derived results project real-case scenarios and provide valuable information for chemical management. As chemicals are increasingly applied to land worldwide, the described techniques may be utilized to determine whether applied chemicals pose adverse effects to human health or the environment.

  18. Integrated Field Lysimetry and Porewater Sampling for Evaluation of Chemical Mobility in Soils and Established Vegetation

    PubMed Central

    Gannon, Travis W.; Polizzotto, Matthew L.

    2014-01-01

    Potentially toxic chemicals are routinely applied to land to meet growing demands on waste management and food production, but the fate of these chemicals is often not well understood. Here we demonstrate an integrated field lysimetry and porewater sampling method for evaluating the mobility of chemicals applied to soils and established vegetation. Lysimeters, open columns made of metal or plastic, are driven into bareground or vegetated soils. Porewater samplers, which are commercially available and use vacuum to collect percolating soil water, are installed at predetermined depths within the lysimeters. At prearranged times following chemical application to experimental plots, porewater is collected, and lysimeters, containing soil and vegetation, are exhumed. By analyzing chemical concentrations in the lysimeter soil, vegetation, and porewater, downward leaching rates, soil retention capacities, and plant uptake for the chemical of interest may be quantified. Because field lysimetry and porewater sampling are conducted under natural environmental conditions and with minimal soil disturbance, derived results project real-case scenarios and provide valuable information for chemical management. As chemicals are increasingly applied to land worldwide, the described techniques may be utilized to determine whether applied chemicals pose adverse effects to human health or the environment. PMID:25045915

  19. Irrigation Water Sources and Time Intervals as Variables on the Presence of Campylobacter spp. and Listeria monocytogenes on Romaine Lettuce Grown in Muck Soil.

    PubMed

    Guévremont, Evelyne; Lamoureux, Lisyanne; Généreux, Mylène; Côté, Caroline

    2017-07-01

    Irrigation water has been identified as a possible source of vegetable contamination by foodborne pathogens. Risk management for pathogens such as Campylobacter spp. and Listeria monocytogenes in fields can be influenced by the source of the irrigation water and the time interval between last irrigation and harvest. Plots of romaine lettuce were irrigated with manure-contaminated water or aerated pond water 21, 7, or 3 days prior to harvesting, and water and muck soil samples were collected at each irrigation treatment. Lettuce samples were collected at the end of the trials. The samples were tested for the presence of Campylobacter spp. and L. monocytogenes. Campylobacter coli was isolated from 33% of hog manure samples (n = 9) and from 11% of the contaminated water samples (n = 27), but no lettuce samples were positive (n = 288). L. monocytogenes was not found in manure, and only one sample of manure-contaminated irrigation water (n = 27) and one lettuce sample (n = 288) were positive. No Campylobacter or L. monocytogenes was recovered from the soil samples (n = 288). Because of the low incidence of pathogens, it was not possible to link the contamination of either soil or lettuce with the type of irrigation water. Nevertheless, experimental field trials mimicking real conditions provide new insights into the survival of two significant foodborne pathogens on romaine lettuce.

  20. Cellscope Aquatic: a Lab Quality, Portable Cellphone-Based Microscope for On-Site Collection of Algae Images

    NASA Astrophysics Data System (ADS)

    Steinberg, S. J.; Howard, M. D.

    2016-02-01

    Collecting algae samples from the field presents issues of specimen damage or degradation caused by preservation methods, handling and transport to laboratory facilities for identification. Traditionally, in-field collection of high quality microscopic images has not been possible due to the size, weight and fragility of high quality instruments and training of field staff in species identification. Scientists at the Southern California Coastal Water Research Project (SCCWRP) in collaboration with the Fletcher Lab, University of California Berkeley, Department of Bioengineering, tested and translated Fletcher's original medical CellScope for use in environmental monitoring applications. Field tests conducted by SCCWRP in 2014 led to modifications of the clinical CellScope to one better suited to in-field microscopic imaging for aquatic organisms. SCCWRP subsequently developed a custom cell-phone application to acquire microscopic imagery using the "CellScope Aquatic "in combination with other cell-phone derived field data (e.g. GPS location, date, time and other field observations). Data and imagery collected in-field may be transmitted in real-time to a web-based data system for tele-taxonomy evaluation and assessment by experts in the office. These hardware and software tools was tested in field in a variety of conditions and settings by multiple algae experts during the spring and summer of 2015 to further test and refine the CellScope Aquatic platform. The CellScope Aquatic provides an easy-to-use, affordable, lightweight, professional quality, data collection platform for environmental monitoring. Our ongoing efforts will focus on development of real-time expert systems for data analysis and image processing, to provide onsite feedback to field scientists.

  1. Water-quality data for water- and wastewater-treatment plants along the Red River of the North, North Dakota and Minnesota, January through October 2006

    USGS Publications Warehouse

    Damschen, William C.; Hansel, John A.; Nustad, Rochelle A.

    2008-01-01

    From January through October 2006, six sets of water-quality samples were collected at 28 sites, which included inflow and outflow from seven major municipal water-treatment plants (14 sites) and influent and effluent samples from seven major municipal wastewater treatment plants (14 sites) along the Red River of the North in North Dakota and Minnesota. Samples were collected in cooperation with the Bureau of Reclamation for use in the development of return-flow boundary conditions in a 2006 water-quality model for the Red River of the North. All samples were analyzed for nutrients and major ions. For one set of effluent samples from each of the wastewater-treatment plants, water was analyzed for Eschirichia coli, fecal coliform, 20-day biochemical oxygen demand, 20-day nitrogenous biochemical oxygen demand, total organic carbon, and dissolved organic carbon. In general, results from the field equipment blank and replicate samples indicate that the overall process of sample collection, processing, and analysis did not introduce substantial contamination and that consistent results were obtained.

  2. DISCUSSION AND EVALUATION OF THE VOLATILITY TEST FOR EQUIVALENCY OF OTHER METHODS TO THE FEDERAL REFERENCE METHOD FOR FINE PARTICULATE MATTER

    EPA Science Inventory

    In July 1997, EPA promulgated a new National Ambient Air Quality Standard (NAAQS) for fine particulate matter (PM2.5). This new standard was based on collection of an integrated mass sample on a filter. Field studies have demonstrated that the collection of semivolatile compoun...

  3. Physiological and morphological characterization of basalt milkvetch (Astragalus filipes): Basis for plant improvement

    Treesearch

    Kishor Bhattarai; Douglas A. Johnson; Thomas A. Jones; Kevin J. Connors; Dale R. Gardner

    2008-01-01

    Astragalus filipes Torr. ex A. Gray (basalt milkvetch or threadstalk milkvetch) is a legume that is widely distributed in western North America andholds promise for revegetation and restoration programs in the western United States. Seed of 67 accessions was collected in 2003 from Utah, Nevada, Idaho, Oregon, California, and Washington. Field-collected forage samples...

  4. Variation in isotopologues of atmospheric nitric acid in passively collected samples along an air pollution gradient in southern California

    Treesearch

    Michael D. Bell; James O. Sickman; Andrzej Bytnerowicz; Pamela E. Padgett; Edith B. Allen

    2014-01-01

    The sources and oxidation pathways of atmospheric nitric acid (HNO3) can be evaluated using the isotopic signatures of oxygen (O) and nitrogen (N). This study evaluated the ability of Nylasorb nylon filters to passively collect unbiased isotopologues of atmospheric HNO3 under controlled and field conditions. Filters...

  5. Multistage Electrophoretic Separators

    NASA Technical Reports Server (NTRS)

    Thomas, Nathan; Doyle, John F.; Kurk, Andy; Vellinger, John C.; Todd, Paul

    2006-01-01

    A multistage electrophoresis apparatus has been invented for use in the separation of cells, protein molecules, and other particles and solutes in concentrated aqueous solutions and suspensions. The design exploits free electrophoresis but overcomes the deficiencies of prior free-electrophoretic separators by incorporating a combination of published advances in mathematical modeling of convection, sedimentation, electro-osmotic flow, and the sedimentation and aggregation of droplets. In comparison with other electrophoretic separators, these apparatuses are easier to use and are better suited to separation in relatively large quantities characterized in the art as preparative (in contradistinction to smaller quantities characterized in the art as analytical). In a multistage electrophoretic separator according to the invention, an applied vertical steady electric field draws the electrically charged particles of interest from within a cuvette to within a collection cavity that has been moved into position of the cuvette. There are multiple collection cavities arranged in a circle; each is aligned with the cuvette for a prescribed short time. The multistage, short-migration-path character of the invention solves, possibly for the first time, the fluid-instability problems associated with free electrophoresis. The figure shows a prototype multistage electrophoretic separator that includes four sample stations and five collection stages per sample. At each sample station, an aqueous solution or suspension containing charged species to be separated is loaded into a cuvette, which is machined into a top plate. The apparatus includes a lower plate, into which 20 collection cavities have been milled. Each cavity is filled with an electrophoresis buffer solution. For the collection of an electrophoretic fraction, the lower plate is rotated to move a designated collection cavity into alignment with the opening of the cuvette. An electric field is then applied between a non-gassing electrode in the collection cavity and an electrolyte compartment, which is separated from the cuvette by a semipermeable membrane. The electrolyte is refreshed by circulation by use of a peristaltic pump. In subsequent steps, the lower plate is rotated to collect other electrophoretic fractions. Later, the collected fractions are removed from the collection cavities through ports that have threaded plugs. The base of the apparatus contains power supplies and a computer interface. The design includes provisions for monitoring and feedback control of cavity position, electric field, and temperature. The operation of the apparatus can easily be automated, as demonstrated by use of software that has already been written for this purpose.

  6. The Internet of Samples in the Earth Sciences: Providing Access to Uncurated Collections

    NASA Astrophysics Data System (ADS)

    Carter, M. R.; Lehnert, K. A.

    2014-12-01

    Vast amounts of physical samples have been collected in the Earth Sciences for studies that address a wide range of scientific questions. Only a fraction of these samples are well curated and preserved long-term in sample repositories and museums. Many samples and collections are stored in the offices and labs of investigators, or in basements and sheds of institutions and investigators' homes. These 'uncurated' collections often contain samples that have been well studied, or are unique and irreplaceable. They may also include samples that could reveal new insights if re-analyzed using new techniques, or specimens that could have unanticipated relevance to research being conducted in fields other than the one for which they were collected. Currently, these samples cannot be accessed or discovered online by the broader science community. Investigators and departments often lack the resources to properly catalog and curate the samples and respond to requests for splits. Long-term preservation of and access to these samples is usually not provided for. iSamplES, a recently-funded EarthCube Research Coordination Network (RCN), seeks to integrate scientific samples, including 'uncurated' samples, into digital data and information infrastructure in the Earth Sciences and to facilitate their curation, discovery, access, sharing, and analysis. The RCN seeks to develop and implement best practices that increase digital access to samples with the goal of establishing a comprehensive infrastructure not only for the digital, but also physical curation of samples. The RCN will engage a broad group of individuals from domain scientists to curators to publishers to computer scientists to define, articulate, and address the needs and challenges of digital sample management and recommend community-endorsed best practices and standards for registering, describing, identifying, and citing physical specimens, drawing upon other initiatives and existing or emerging software tools for digital sample and collection management. Community engagement will include surveys, in-person workshops and outreach events, the creation of the iSamplES knowledge hub (semantic wiki) and a registry of collections. iSamplES will specifically engage early career scientists to encourage that no samples go uncurated.

  7. Delineating high-density areas in spatial Poisson fields from strip-transect sampling using indicator geostatistics: application to unexploded ordnance removal.

    PubMed

    Saito, Hirotaka; McKenna, Sean A

    2007-07-01

    An approach for delineating high anomaly density areas within a mixture of two or more spatial Poisson fields based on limited sample data collected along strip transects was developed. All sampled anomalies were transformed to anomaly count data and indicator kriging was used to estimate the probability of exceeding a threshold value derived from the cdf of the background homogeneous Poisson field. The threshold value was determined so that the delineation of high-density areas was optimized. Additionally, a low-pass filter was applied to the transect data to enhance such segmentation. Example calculations were completed using a controlled military model site, in which accurate delineation of clusters of unexploded ordnance (UXO) was required for site cleanup.

  8. PubMed Central

    Miezan, T.; Doua, F.; Cattand, P.; de Raadt, P.

    1991-01-01

    The Testryp CATT was performed on dried blood samples on filter-paper and on diluted blood using a microtechnique. This method was applied to both sample collection techniques and was evaluated in parallel with the classical Testryp CATT on whole blood, as described in the instructions provided with the reagents by the manufacturer. A total of 2087 people were tested; 453 samples were tested in the laboratory and 1634 during a field survey in 5 villages of a trypanosomiasis focus in Daloa, Côte d'Ivoire. This study has demonstrated that the Testryp CATT micromethod on either type of sample collection gives results comparable to the Testryp CATT on whole blood. The collection of dried blood samples on filter-paper can be performed by non-specialized staff in trypanosomiasis control programmes of the national health services. In addition, a flask of CATT reagent will allow testing of 6 times more people by the micromethod than by the classical whole-blood method. The micromethod is suitable in the implementation of programmes for the serological surveillance of populations at risk. PMID:1959162

  9. Real-time PCR detection of Plasmodium directly from whole blood and filter paper samples

    PubMed Central

    2011-01-01

    Background Real-time PCR is a sensitive and specific method for the analysis of Plasmodium DNA. However, prior purification of genomic DNA from blood is necessary since PCR inhibitors and quenching of fluorophores from blood prevent efficient amplification and detection of PCR products. Methods Reagents designed to specifically overcome PCR inhibition and quenching of fluorescence were evaluated for real-time PCR amplification of Plasmodium DNA directly from blood. Whole blood from clinical samples and dried blood spots collected in the field in Colombia were tested. Results Amplification and fluorescence detection by real-time PCR were optimal with 40× SYBR® Green dye and 5% blood volume in the PCR reaction. Plasmodium DNA was detected directly from both whole blood and dried blood spots from clinical samples. The sensitivity and specificity ranged from 93-100% compared with PCR performed on purified Plasmodium DNA. Conclusions The methodology described facilitates high-throughput testing of blood samples collected in the field by fluorescence-based real-time PCR. This method can be applied to a broad range of clinical studies with the advantages of immediate sample testing, lower experimental costs and time-savings. PMID:21851640

  10. Hydrogeochemical and stream sediment special reconnaissance report for the Deep Creek Mountains, Nevada and Utah

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qualheim, B.

    1979-04-01

    This report represents the results of the reconnaissance sampling of the Deep Creek Mountains of western Utah. The Deep Creek range is located in the northwest corner of the Delta NTMS 1:250,000 and the southwestern corner of the Tooele NTMS 1:250,000 sheets and covers an area of 1750 km/sup 2/. Samples collected in this study include dry and wet stream sediments and water from available streams, wells, and springs. The samples were analyzed for uranium, as well as 15 to 20 trace elements, using neutron activation techniques. In addition, field and laboratory measurements were made on the water samples. Analyticalmore » data and field measurements are presented in tabular hard copy and fiche format. Water-sample site locations, water-sample uranium concentrations, sediment-sample site locations, and sediment-sample uranium concentrations are shown on separate overlays.« less

  11. INNOVATIVE TECHNOLOGY VERIFICATION REPORT " ...

    EPA Pesticide Factsheets

    The EnSys Petro Test System developed by Strategic Diagnostics Inc. (SDI), was demonstrated under the U.S. Environmental Protection Agency Superfund Innovative Technology Evaluation Program in June 2000 at the Navy Base Ventura County site in Port Hueneme, California. The purpose of the demonstration was to collect reliable performance and cost data for the EnSys Petro Test System and six other field measurement devices for total petroleum hydrocarbons (TPH) in soil. In addition to assessing ease of device operation, the key objectives of the demonstration included determining the (1) method detection limit, (2) accuracy and precision, (3) effects of interferents and soil moisture content on TPH measurement, (4) sample throughput, and (5) TPH measurement costs for each device. The demonstration involved analysis of both performance evaluation samples and environmental samples collected in four areas contaminated with gasoline, diesel, or other petroleum products. The performance and cost results for a given field measurement device were compared to those for an off-site laboratory reference method,

  12. INNOVATIVE TECHNOLOGY VERIFICATION REPORT " ...

    EPA Pesticide Factsheets

    The Synchronous Scanning Luminoscope (Luminoscope) developed by the Oak Ridge National Laboratory in collaboration with Environmental Systems Corporation (ESC) was demonstrated under the U.S. Environmental Protection Agency Superfund Innovative Technology Evaluation Program in June 2000 at the Navy Base Ventura County site in Port Hueneme, California. The purpose of the demonstration was to collect reliable performance and cost data for the Luminoscope and six other field measurement devices for total petroleum hydrocarbons (TPH) in soil. In addition to assessing ease of device operation, the key objectives of the demonstration included determining the (1) method detection limit, (2) accuracy and precision, (3) effects of interferents and soil moisture content on TPH measurement, (4) sample throughput, and (5) TPH measurement costs for each device. The demonstration involved analysis of both performance evaluation samples and environmental samples collected in five areas contaminated with gasoline, diesel, lubricating oil, or other petroleum products. The performance and cost results for a given field measurement device were compared to those for an off-site laboratory reference method,

  13. Leaching of polycyclic aromatic hydrocarbons from oil shale processing waste deposit: a long-term field study.

    PubMed

    Jefimova, Jekaterina; Irha, Natalya; Reinik, Janek; Kirso, Uuve; Steinnes, Eiliv

    2014-05-15

    The leaching behavior of selected polycyclic aromatic hydrocarbons (PAHs) from an oil shale processing waste deposit was monitored during 2005-2009. Samples were collected from the deposit using a special device for leachate sampling at field conditions without disturbance of the upper layers. Contents of 16 priority PAHs in leachate samples collected from aged and fresh parts of the deposit were determined by GC-MS. The sum of the detected PAHs in leachates varied significantly throughout the study period: 19-315 μg/l from aged spent shale, and 36-151 μg/l from fresh spent shale. Among the studied PAHs the low-molecular weight compounds phenanthrene, naphthalene, acenaphthylene, and anthracene predominated. Among the high-molecular weight PAHs benzo[a]anthracene and pyrene leached in the highest concentrations. A spent shale deposit is a source of PAHs that could infiltrate into the surrounding environment for a long period of time. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Natural organic matter properties in Swedish agricultural streams

    NASA Astrophysics Data System (ADS)

    Bieroza, Magdalena; Kyllmar, Katarina; Bergström, Lars; Köhler, Stephan

    2017-04-01

    The following paper shows natural organic matter (NOM) properties of stream water samples collected from 8 agricultural streams and 12 agricultural observational fields in Sweden. The catchments and observational fields cover a broad range of environmental (climate, soil type), land use and water quality (nutrient and concentrations, pH, alkalinity) characteristics. Stream water samples collected every two weeks within an ongoing Swedish Monitoring Programme for Agriculture have been analysed for total/dissolved organic carbon, absorbance and fluorescence spectroscopy. A number of quantitative and qualitative spectroscopic parameters was calculated to help to distinguish between terrestrially-derived, refractory organic material and autochthonous, labile material indicative of biogeochemical transformations of terrestrial NOM and recent biological production. The study provides insights into organic matter properties and carbon budgets in agricultural streams and improves understanding of how agricultural catchments transform natural and anthropogenic fluxes of organic matter and nutrients. The insights from the grab sampling are supported by high-frequency turbidity, fulvic-like and tryptophan-like fluorescence measurements with in situ optical sensor.

  15. Preliminary Assessment/Site Inspection Work Plan for Granite Mountain Radio Relay System

    DTIC Science & Technology

    1994-09-01

    represent field conditions, and (3) sampling results are repeatable. Final (04 WV---,,1-, ,W•, S 2, mbr . 19W4 13 RyCWed 1.5.2 Sample Handling Sample...procedures specified in Section 2.1.3. Samples collected from shallow depths will be obtained by submerging a stainless- steel, Teflon, or glass... submerged in a manner that minimizes agitation of sediment and the water sample. If a seep or spring has minimal discharge flow, gravel, boulders, and soil

  16. Loop-Mediated Isothermal Amplification (LAMP) assay for the identification of Echinococcus multilocularis infections in canine definitive hosts

    PubMed Central

    2014-01-01

    Background Alveolar echinococcosis, caused by the metacestode larval stage of Echinococcus multilocularis, is a zoonosis of public health significance and is highly prevalent in northwest China. To effectively monitor its transmission, we developed a new rapid and cheap diagnostic assay, based on loop-mediated isothermal amplification (LAMP), to identify canine definitive hosts infected with E. multilocularis. Methods The primers used in the LAMP assay were based on the mitochondrial nad5 gene of E. multilocularis and were designed using Primer Explorer V4 software. The developed LAMP assay was compared with a conventional PCR assay, using DNA extracted from the feces of dogs experimentally infected with E. multilocularis, on 189 dog fecal samples collected from three E. multilocularis-endemic regions in Qinghai province, the People’s Republic of China, and 30 negative control copro-samples from dogs from an area in Gansu province that had been subjected to an intensive de-worming program. Light microscopy was also used to examine the experimentally obtained and field collected dog copro-samples for the presence of E. multilocularis eggs. Results The E. multilocularis-positivity rates obtained for the field-collected fecal samples were 16.4% and 5.3% by the LAMP and PCR assays, respectively, and all samples obtained from the control dogs were negative. The LAMP assay was able to detect E. multilocularis DNA in the feces of experimentally infected dogs at 12 days post-infection, whereas the PCR assay was positive on the 17th day and eggs were first detectable by light microscopy at day 44 post-challenge. Conclusion The earlier specific detection of an E. multilocularis infection in dog copro-samples indicates that the LAMP assay we developed is a realistic alternative method for the field surveillance of canines in echinococcosis-endemic areas. PMID:24886279

  17. Source apportionment of methane using a triple isotope approach - Method development and application in the Baltic Sea

    NASA Astrophysics Data System (ADS)

    Steinbach, Julia; Holmstrand, Henry; Semiletov, Igor; Shakhova, Natalia; Shcherbakova, Kseniia; Kosmach, Denis; Sapart, Célia J.; Gustafsson, Örjan

    2015-04-01

    We present a method for measurements of the stable and radiocarbon isotope systems of methane in seawater and sediments. The triple isotope characterization of methane is useful in distinguishing different sources and for improving our understanding of biogeochemical processes affecting methane in the water column. D14C-CH4 is an especially powerful addition to stable isotope analyses in distinguishing between thermogenic and biogenic origins of the methane. Such measurements require large sample sizes, due to low natural abundance of the radiocarbon in CH4. Our system for sample collection, methane extraction and purification builds on the approach by Kessler and Reeburgh (Limn. & Ocean. Meth., 2005). An in-field system extracts methane from 30 -120 l water or 1-2 l sediment (depending on the in-situ methane concentration) by purging the samples with Helium to transfer the dissolved methane to the headspace and circulating it through cryogenically cooled absorbent traps where methane is collected. The in-field preparation eliminates the risks of storage and transport of large seawater quantities and subsequent leakage of sample gas as well as ongoing microbial processes and chemical reactions that may alter the sample composition. In the subsequent shore-based treatment, a laboratory system is used to purify and combust the collected CH4 to AMS-amenable CO2. Subsamples from the methane traps are analyzed for stable isotopes and compared to stable isotope measurements directly measured from small water samples taken in parallel, to correct for any potential fractionation occurring during this process. The system has been successfully tested and used on several shorter shipboard expeditions in the Baltic Sea and on a long summer expedition across the Arctic Ocean. Here we present the details of the method and testing, as well as first triple isotope field data from two cruises to the Landsort Deep area in the Central Baltic Sea.

  18. Use of novel RT-PCR assay to detect picobirnavirus in Poultry Intestinal samples collected from the field

    USDA-ARS?s Scientific Manuscript database

    Recent metagenomic analyses of the turkey gut ribonucleic acid (RNA) virus community in our laboratory have identified novel enteric RNA viruses that may play roles in the poultry enteric diseases and in performance problems noted in the field. This has lead to new molecular diagnostic assays for ce...

  19. National Household Education Surveys of 2003: Data File User's Manual, Volume I. NCES 2004-001

    ERIC Educational Resources Information Center

    Hagedorn, Mary; Montaquila, Jill; Vaden-Kiernan, Nancy; Kim, Kwang; Chapman, Christopher

    2004-01-01

    This manual describes the development of the surveys fielded in 2003 under the National Household Education Surveys Program (NHES: 2003). It describes how the questionnaires were designed, how the samples were developed, data collection experiences, and file information needed to analyze the NHES: 2003 data sets. The surveys fielded as part of…

  20. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR FIELD USE OF THE MODIFIED AIR SENTINEL (UA-F-10.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the in-field use of the modified Air Sentinel. Samples collected with this Hi-Vol instrument were analyzed for atmospheric concentrations of target metals. This procedure was followed to ensure consistent data retrieval of air and dust ana...

  1. The Influence of Landscape Heterogeneity - Ground Beetles (Coleoptera: Carabidae) in Fthiotida, Central Greece

    PubMed Central

    2014-01-01

    Abstract Pitfall traps were used to sample Carabidae in agricultural land of the Spercheios valley, Fthiotida, Central Greece. Four pairs of cultivated fields were sampled. One field of each pair was located in a heterogeneous area and the other in a more homogeneous area. Heterogeneous areas were composed of small fields. They had high percentages of non-cropped habitats and a high diversity of land use types. Homogeneous areas were composed of larger fields. They had lower percentages of non-cropped habitats and a lower diversity of land use types. One pair of fields had been planted with cotton, one with maize, one with olives and one with wheat. Altogether 28 carabid species were recorded. This paper describes the study areas, the sampling methods used and presents the data collected during the study. Neither heterogeneous nor homogeneous areas had consistently higher abundance levels, activity density levels, species richness levels or diversity levels. However, significant differences were seen in some of the comparisons between heterogeneous and homogeneous areas. PMID:24891833

  2. Geology-based method of assessing sensitivity of streams to acidic deposition in Charles and Anne Arundel Counties, Maryland

    USGS Publications Warehouse

    Rice, Karen C.; Bricker, Owen P.

    1991-01-01

    The report describes the results of a study to assess the sensitivity of streams to acidic deposition in Charles and Anne Arundel Counties, Maryland using a geology-based method. Water samples were collected from streams in July and August 1988 when streams were at base-flow conditions. Eighteen water samples collected from streams in Charles County, and 17 water samples from streams in Anne Arundel County were analyzed in the field for pH, specific conductance, and acid-neutralizing capacity (ANC); 8 water samples from streams in Charles County were analyzed in the laboratory for chloride and sulfate concentrations. The assessment revealed that streams in these counties are sensitive to acidification by acidic deposition.

  3. Evidence of Hybridization between Common Gartersnakes (Thamnophis sirtalis) and Butler’s Gartersnakes (Thamnophis butleri) in Wisconsin (USA).

    USGS Publications Warehouse

    Joshua M. Kapfer,; Sloss, Brian L.; Gregor W. Schuurman,; Paloski, Rori A.; Jeffrey M. Lorch,

    2013-01-01

    Snakes within the genus Thamnophis (Gartersnakes and Ribbonsnakes) are often found in sympatry throughout their geographic distributions. Past work has indicated that some sympatric species within this genus may hybridize, but research of this nature is limited. We attempted to determine whether hybridization occurs between two Thamnophis species native to the upper midwestern United States: Common Gartersnake (Thamnophis sirtalis) and the Butler's Gartersnake (Thamnophis butleri). We sampled snakes (n = 411) across 26 locations in Wisconsin, including sites where both species coexist and sites where only Common Gartersnakes are found. We conducted genetic analyses on tissue collected from individuals field-identified as Common Gartersnakes or Butler's Gartersnakes. To verify the results of our field-collected data, we analyzed tissues from juvenile snakes (n = 4) suspected to be the offspring of a Common Gartersnake and a Butler's Gartersnake that were housed together in a captive situation. Of the field-collected snakes analyzed, eight snakes were consistent with expected Common × Butler's Gartersnake hybrids. All four of the captive offspring analyzed resolved as putative hybrids, corresponding with our field-collected samples. Butler's Gartersnake is a globally rare species, endemic only to the upper midwestern United States. Studies involving the potential for hybridization between common and uncommon species are useful from a conservation perspective. The low incidence of hybridization we observed would indicate that hybridization between these species is uncommon. Further research investigating rates of hybridization would help assess any potential threat posed by outbreeding between common and rare gartersnakes in this region of the United States.

  4. A new sampler for stratified lagoon chemical and microbiological assessments.

    PubMed

    McLaughlin, M R; Brooks, J P; Adeli, A

    2014-07-01

    A sampler was needed for a spatial and temporal study of microbial and chemical stratification in a large swine manure lagoon that was known to contain zoonotic bacteria. Conventional samplers were limited to collections of surface water samples near the bank or required a manned boat. A new sampler was developed to allow simultaneous collection of multiple samples at different depths, up to 2.3 m, without a manned boat. The sampler was tethered for stability, used remote control (RC) for sample collection, and accommodated rapid replacement of sterile tubing modules and sample containers. The sampler comprised a PVC pontoon with acrylic deck and watertight enclosures, for a 12 VDC gearmotor, to operate the collection module, and vacuum system, to draw samples into reusable autoclavable tubing and 250-mL bottles. Although designed primarily for water samples, the sampler was easily modified to collect sludge. The sampler held a stable position during deployment, created minimal disturbance in the water column, and was readily cleaned and sanitized for transport. The sampler was field tested initially in a shallow fresh water lake and subsequently in a swine manure treatment lagoon. Analyses of water samples from the lagoon tests showed that chemical and bacterial levels, pH, and EC did not differ between 0.04, 0.47, and 1.0 m depths, but some chemical and bacterial levels differed between winter and spring collections. These results demonstrated the utility of the sampler and suggested that future manure lagoon studies employ fewer or different depths and more sampling dates.

  5. USGS field activity 09FSH02 on the west Florida shelf, Gulf of Mexico, in August 2009

    USGS Publications Warehouse

    Robbins, Lisa L.; Knorr, Paul O.; Liu, Xuewu; Byrne, Robert H.; Raabe, Ellen A.

    2009-01-01

    From August 17 to 21, 2009, a cruise led by the U.S. Geological Survey (USGS) collected air and sea surface partial pressure of carbon dioxide (pCO2), pH, dissolved inorganic carbon (DIC), and total alkalinity (TA) data on the west Florida shelf. Approximately 2,000 data points were collected underway over a 1,320-kilometer (km) track line using the Multiparameter Inorganic Carbon Analyzer (MICA). The collection of data extended from Crystal River to Marco Island, Florida (~400 km), and westward up to 160 km off the Florida coast. Discrete water samples were also taken at specific localities to corroborate underway data measurements. The USGS St. Petersburg Coastal and Marine Science Center (SPCMSC) assigns a unique identifier to each cruise or field activity. For example, 09FSH02 tells us that the data were collected in 2009 for the Response of Florida Shelf (FSH) Ecosystems to Climate Change project, and the data were collected during the second field activity for that study in that calendar year.

  6. USGS field activity 09FSH01 on the west Florida shelf, Gulf of Mexico, in February 2009

    USGS Publications Warehouse

    Robbins, Lisa L.; Knorr, Paul O.; Liu, Xuewu; Byrne, Robert H.; Raabe, Ellen A.

    2009-01-01

    From February 24 to 28, 2009, a cruise led by the U.S. Geological Survey (USGS) collected air and sea surface partial pressure of carbon dioxide (pCO2), pH, dissolved inorganic carbon (DIC), and total alkalinity (TA) data on the west Florida shelf. Approximately 1,800 data points were collected underway over a 1,300-kilometer (km) trackline using the Multiparameter Inorganic Carbon Analyzer (MICA). The collection of data extended from Crystal River to Marco Island, Florida (~400 km), and westward up to 160 km off the Florida coast. Discrete water samples were also taken at specific localities to corroborate underway data measurements. The USGS St. Petersburg Coastal and Marine Science Center (SPCMSC) assigns a unique identifier to each cruise or field activity. For example, 09FSH01 tells us that the data were collected in 2009 for the Response of Florida Shelf (FSH) Ecosystems to Climate Change project, and the data were collected during the first field activity for that study in that calendar year.

  7. USGS field activity 08FSH01 on the west Florida shelf, Gulf of Mexico, in August 2008

    USGS Publications Warehouse

    Robbins, Lisa L.; Knorr, Paul O.; Liu, Xuewu; Byrne, Robert H.; Raabe, Ellen A.

    2009-01-01

    From August 11 to 15, 2008, a cruise led by the U.S. Geological Survey (USGS) collected air and sea surface partial pressure of carbon dioxide (pCO2), pH, dissolved inorganic carbon (DIC), and total alkalinity (TA) data on the west Florida shelf. Approximately 1,600 data points were collected underway over a 650-kilometer (km) trackline using the Multiparameter Inorganic Carbon Analyzer (MICA). The collection of data extended from Crystal River southward to Marco Island, Florida (~400 km), and westward up to 160 km off the Florida coast. Discrete water samples from approximately 40 locations were also taken at specific localities to corroborate underway data measurements. The USGS St. Petersburg Coastal and Marine Science Center (SPCMSC) assigns a unique identifier to each cruise or field activity. For example, 08FSH01 tells us the data were collected in 2008 for the Response of Florida Shelf (FSH) Ecosystems to Climate Change project, and the data were collected during the first field activity for that study in that calendar year.

  8. [Parasitic infections of coyote, Canis latrans (Carnivora: Canidae) in a Costa Rican National Park and a surrounding agricultural area].

    PubMed

    Niehaus, Carmen; Valerio, Idalia; Blanco, Kinndle; Chinchilla, Misael

    2012-06-01

    As human populations expand into wild habitats with their pets and livestock, the potential spread of disease to wildlife or vice versa increases. Because, wild and domestic canids may pose as reservoirs or disseminators of infectious diseases (including parasites), coyotes (Canis latrans) may also serve as indicators of ecological health. In Costa Rica, little information exists on coyote parasites, making research necessary to identify potential zoonotic interactions. For this reason, a survey of the coyote parasites was performed in a mixed area of protected woodland and agricultural land, surrounding Irazú Volcano National Park (IVNP) in Cartago, Costa Rica. Over a one-year period, 209 fecal samples were collected directly from the ground. Collection took place on a monthly basis in a trail sectioned into three sub-areas named Irazú (closest to the volcano), potato fields (where potatoes were cultivated), and Prusia (a protected sector of IVNP). Sectioning the trail allowed separate collection and analysis of the samples, where 99 were obtained from Irazú, 11 from potato fields and 99 from Prusia. Using direct examination and mechanical concentration 36.84% positive samples containing at least one helminth were found. The presence of parasites was similar for both woodland areas (33.3% in Prusia and 37.4% in Irazú), but differed from the 63.6% observed in the potato fields. Hookworm parasites (probably Ancylostoma caninum), threadworms (possibly Strongyloides sp.), Toxocara canis, Trichuris sp. and Taenia pisiformis were identified, as well as Hymenolepis diminuta, possible spurious parasite resulting from the ingestion of rodents by coyotes. Seasonal details are discussed, concluding that wet and dry seasons affect presence of parasites. Some remarks are made on the importance of these first findings for Costa Rica, especially considering the systematic way in which the collection of samples was carried out.

  9. Phase II Interim Report -- Assessment of Hydrocarbon Seepage Detection Methods on the Fort Peck Reservation, Northeast Montana

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Monson, Lawrence M.

    2002-04-24

    The following work was performed: (1) collected reconnaissance micro-magnetic data and background field data for Area 1, (2) identified and collected soil sample data in three anomalous regions of Area 1, (3) sampled soils in Northwest Poplar Oil Field, (4) graphed, mapped, and interpreted all data areas listed above, (5) registered for the AAPG Penrose Conference on Hydrocarbon Seepage Mechanisms and Migration (postponed from 9/16/01 until 4/7/02 in Vancouver, B.C.). Results include the identification and confirmation of an oil and gas prospect in the northwest part of Area 1 and the verification of a potential shallow gas prospect in themore » West Poplar Area. Correlation of hydrocarbon micro-seepage to TM tonal anomalies needs further data analysis.« less

  10. Common methods for fecal sample storage in field studies yield consistent signatures of individual identity in microbiome sequencing data.

    PubMed

    Blekhman, Ran; Tang, Karen; Archie, Elizabeth A; Barreiro, Luis B; Johnson, Zachary P; Wilson, Mark E; Kohn, Jordan; Yuan, Michael L; Gesquiere, Laurence; Grieneisen, Laura E; Tung, Jenny

    2016-08-16

    Field studies of wild vertebrates are frequently associated with extensive collections of banked fecal samples-unique resources for understanding ecological, behavioral, and phylogenetic effects on the gut microbiome. However, we do not understand whether sample storage methods confound the ability to investigate interindividual variation in gut microbiome profiles. Here, we extend previous work on storage methods for gut microbiome samples by comparing immediate freezing, the gold standard of preservation, to three methods commonly used in vertebrate field studies: lyophilization, storage in ethanol, and storage in RNAlater. We found that the signature of individual identity consistently outweighed storage effects: alpha diversity and beta diversity measures were significantly correlated across methods, and while samples often clustered by donor, they never clustered by storage method. Provided that all analyzed samples are stored the same way, banked fecal samples therefore appear highly suitable for investigating variation in gut microbiota. Our results open the door to a much-expanded perspective on variation in the gut microbiome across species and ecological contexts.

  11. Temporal variation (seasonal and interannual) of vegetation indices of maize and soybeans across multiple years in central Iowa

    NASA Astrophysics Data System (ADS)

    Prueger, J. H.; Hatfield, J. L.

    2015-09-01

    Remotely sensed reflectance parameters from corn and soybean surfaces can be correlated to crop production. Surface reflectance of a typical Upper Midwest corn /soybean region in central Iowa across multiple years reveal subtle dynamics in vegetative surface response to a continually varying climate. From 2006 through 2014 remotely sensed data have been acquired over production fields of corn and soybeans in central IA, U.S.A. with the fields alternating between corn and soybeans. The data have been acquired using ground-based radiometers with 16 wavebands covering the visible, near infrared, shortwave infrared wavebands and combined into a series of vegetative indices. These data were collected on clear days with the goal of collecting data at a minimum of once per week from prior to planting until after fall tillage operations. Within each field, five sites were established and sampled during the year to reduce spatial variation and allow for an assessment of changes in the vegetative indices throughout the growing season. Ancillary data collected for each crop included the phenological stage at each sampling date along with biomass sampled at the onset of the reproductive stage and at physiological maturity. Evaluation of the vegetative indices for the different years revealed that patterns were related to weather effects on corn and soybean growth. Remote sensing provides a method to evaluate changes within and among growing seasons to assess crop growth and development as affected by differences in weather variability.

  12. Sample integrity evaluation and EPA method 325B interlaboratory comparison for select volatile organic compounds collected diffusively on Carbopack X sorbent tubes

    NASA Astrophysics Data System (ADS)

    Oliver, Karen D.; Cousett, Tamira A.; Whitaker, Donald A.; Smith, Luther A.; Mukerjee, Shaibal; Stallings, Casson; Thoma, Eben D.; Alston, Lillian; Colon, Maribel; Wu, Tai; Henkle, Stacy

    2017-08-01

    A sample integrity evaluation and an interlaboratory comparison were conducted in application of U.S. Environmental Protection Agency (EPA) Methods 325A and 325B for diffusively monitoring benzene and other selected volatile organic compounds (VOCs) using Carbopack X sorbent tubes. To evaluate sample integrity, VOC samples were refrigerated for up to 240 days and analyzed using thermal desorption/gas chromatography-mass spectrometry at the EPA Office of Research and Development laboratory in Research Triangle Park, NC, USA. For the interlaboratory comparison, three commercial analytical laboratories were asked to follow Method 325B when analyzing samples of VOCs that were collected in field and laboratory settings for EPA studies. Overall results indicate that the selected VOCs collected diffusively on sorbent tubes generally were stable for 6 months or longer when samples were refrigerated. This suggests the specified maximum 30-day storage time of VOCs collected diffusively on Carbopack X passive samplers and analyzed using Method 325B might be able to be relaxed. Interlaboratory comparison results were in agreement for the challenge samples collected diffusively in an exposure chamber in the laboratory, with most measurements within ±25% of the theoretical concentration. Statistically significant differences among laboratories for ambient challenge samples were small, less than 1 part per billion by volume (ppbv). Results from all laboratories exhibited good precision and generally agreed well with each other.

  13. Comparison of water-quality samples collected by siphon samplers and automatic samplers in Wisconsin

    USGS Publications Warehouse

    Graczyk, David J.; Robertson, Dale M.; Rose, William J.; Steur, Jeffrey J.

    2000-01-01

    In small streams, flow and water-quality concentrations often change quickly in response to meteorological events. Hydrologists, field technicians, or locally hired stream ob- servers involved in water-data collection are often unable to reach streams quickly enough to observe or measure these rapid changes. Therefore, in hydrologic studies designed to describe changes in water quality, a combination of manual and automated sampling methods have commonly been used manual methods when flow is relatively stable and automated methods when flow is rapidly changing. Auto- mated sampling, which makes use of equipment programmed to collect samples in response to changes in stage and flow of a stream, has been shown to be an effective method of sampling to describe the rapid changes in water quality (Graczyk and others, 1993). Because of the high cost of automated sampling, however, especially for studies examining a large number of sites, alternative methods have been considered for collecting samples during rapidly changing stream conditions. One such method employs the siphon sampler (fig. 1). also referred to as the "single-stage sampler." Siphon samplers are inexpensive to build (about $25- $50 per sampler), operate, and maintain, so they are cost effective to use at a large number of sites. Their ability to collect samples representing the average quality of water passing though the entire cross section of a stream, however, has not been fully demonstrated for many types of stream sites.

  14. A method for development of a system of identification for Appalachian coal-bearing rocks

    USGS Publications Warehouse

    Ferm, J.C.; Weisenfluh, G.A.; Smith, G.C.

    2002-01-01

    The number of observable properties of sedimentary rocks is large and numerous classifications have been proposed for describing them. Some rock classifications, however, may be disadvantageous in situations such as logging rock core during coal exploration programs, where speed and simplicity are the essence. After experimenting with a number of formats for logging rock core in the Appalachian coal fields, a method of using color photographs accompanied by a rock name and numeric code was selected. In order to generate a representative collection of rocks to be photographed, sample methods were devised to produce a representative collection, and empirically based techniques were devised to identify repeatedly recognizable rock types. A number of cores representing the stratigraphic and geographic range of the region were sampled so that every megascopically recognizable variety was included in the collection; the frequency of samples of any variety reflects the frequency with which it would be encountered during logging. In order to generate repeatedly recognizable rock classes, the samples were sorted to display variation in grain size, mineral composition, color, and sedimentary structures. Class boundaries for each property were selected on the basis of existing, widely accepted limits and the precision with which these limits could be recognized. The process of sorting the core samples demonstrated relationships between rock properties and indicated that similar methods, applied to other groups of rocks, could yield more widely applicable field classifications. ?? 2002 Elsevier Science B.V. All rights reserved.

  15. Methylmercury and other chemical constituents in Pacific coastal fog water from seven sites in Central/Northern California (FogNet) during the summer of 2014

    NASA Astrophysics Data System (ADS)

    Weiss-Penzias, P. S.; Heim, W. A.; Fernandez, D.; Coale, K. H.; Oliphant, A. J.; Dann, D.; Porter, M.; Hoskins, D.; Dodge, C.

    2014-12-01

    This project investigates the mercury content in summertime Pacific coastal fog in California and whether fog could be an important vector for ocean emissions of mercury to be deposited via fog drip to upland coastal ecosystems. Efforts began in early 2014 with the building of 7 active-strand fog collectors based on the Colorado State University Caltech CASCC design. The new UCSC CASCC includes doors sealing the collector which open under microcomputer control based on environmental sensing (relative humidity). Seven sites spanning from Trinidad in the north to Marina in the south have collected samples June-August 2014 under a project called FogNet. Fog conditions were favorable for collecting large water volumes (> 250 mL) at many sites. Fog samplers were cleaned with soap and deionized water daily and field blanks taken immediately following cleaning. Fog water samples were collected overnight, split into an aliquot for anion and DOC/DIC analysis and the remaining sample was acidified. Monomethyl mercury (MMHg) concentrations in samples and field blanks for 3 sites in FogNet are shown in the accompanying figure. The range of MMHg concentrations from 10 fog water samples > 100 mL in volume was 0.9-9.3 ng/L (4.5-46.4 pM). Elevated MMHg concentrations (> 5 ng/L, 25 pM) were observed at 2 sites: UC Santa Cruz and Bodega Bay. The field blanks produced MMHg concentrations of 0.08-0.4 ng/L (0.4-2.0 pM), which was on average < 10% of the sample concentration and suggests the artifact due to sampling was small. The observed MMHg concentrations in fog water observed is this study are 1-2 orders of magnitude greater than MMHg concentrations seen previously in rain water samples from the California coast suggesting an additional source of MMHg to fog. Shipboard measurements of dimethyl mercury (DMHg) in coastal California seawater during the time period of FogNet operations (summer 2014) reveal surface waters that were supersaturated in DMHg which represents a potential source of organic mercury to the overlying fog bank.

  16. Electrophoresis device

    NASA Technical Reports Server (NTRS)

    Rhodes, P. H.; Snyder, R. S. (Inventor)

    1982-01-01

    A device for separating cellular particles of a sample substance into fractionated streams of different cellular species includes a casing having a distribution chamber, a separation chamber, and a collection chamber. The electrode chambers are separated from the separation chamber interior by means of passages such that flow variations and membrane variations around the slotted portion of the electrode chamber do not enduce flow perturbations into the laminar buffer curtain flowing in the separation chamber. The cellular particles of the sample are separated under the influence of the electrical field and the separation chamber into streams of different cellular species. The streams of separated cells enter a partition array in the collection chamber where they are fractionated and collected.

  17. Reconnaissance for uranium in the coal of Sao Paulo, Santa Catarina, and Rio Grande do Sul, Brazil

    USGS Publications Warehouse

    Haynes, Donald D.; Pierson, Charles T.; White, Max G.

    1958-01-01

    Uranium-bearing coal and carbonaceous shale of the Rio Bonito formation of Pennsylvanian age have been found in the States of Sao Paulo, Santa Catarlna and Rio Grande do Sul, Brazil. The uranium oxide content of the samples collected in the State of Sao Paulo ranges from 0.001 percent to 0.082 percent. The samples collected in Santa Catarina averaged about 0.002 percent uranium oxide; those collected in Rio Grande do Sul, about 0.003 percent uranium oxide. Since the field and laboratory investigations are still in their initial stages, only raw data on the radioactivity and uranium content of Brazilian coals are given in this report.

  18. Herbicides and herbicide degradates in shallow groundwater and the Cedar River near a municipal well field, Cedar Rapids, Iowa

    USGS Publications Warehouse

    Boyd, R.A.

    2000-01-01

    Water samples were collected near a Cedar Rapids, Iowa municipal well field from June 1998 to August 1998 and analyzed for selected triazine and acetanilide herbicides and degradates. The purpose of the study was to evaluate the occurrence of herbicides and herbicide degradates in the well field during a period following springtime application of herbicides to upstream cropland. The well field is in an alluvial aquifer adjacent to the Cedar River. Parent herbicide concentrations generally were greatest in June, and decreased in July and August. Atrazine was most frequently detected and occurred at the greatest concentrations; acetochlor, cyanazine and metolachlor also were detected, but at lesser concentrations than atrazine. Triazine degradate concentrations were relatively small (<0.50 ??g/l) and generally decreased from June to August. Although the rate of groundwater movement is relatively fast (approx. 1 m per day) in the alluvial aquifer near the Cedar River, deethylatrazine (DEA) to atrazine ratios in groundwater samples collected near the Cedar River indicate that atrazine and DEA probably are gradually transported into the alluvial aquifer from the Cedar River. Deisopropylatrazine (DIA) to DEA ratios in water samples indicate most DIA in the Cedar River and alluvial aquifer is produced by atrazine degradation, although some could be from cyanazine degradation. Acetanilide degradates were detected more frequently and at greater concentrations than their corresponding parent herbicides. Ethanesulfonic-acid (ESA) degradates comprised at least 80% of the total acetanilide-degradate concentrations in samples collected from the Cedar River and alluvial aquifer in June, July and August; oxanilic acid degradates comprised less than 20% of the total concentrations. ESA-degradate concentrations generally were smallest in June and greater in July and August. Acetanilide degradate concentrations in groundwater adjacent to the Cedar River indicate acetanilide degradates are transported into the alluvial aquifer in a manner similar to that indicated for atrazine and DEA. Copyright (C) 2000 Elsevier Science B.V.

  19. Study of the second magnetization peak and the pinning behaviour in Ba(Fe0.935Co0.065)2As2 pnictide superconductor

    NASA Astrophysics Data System (ADS)

    Sundar, Shyam; Mosqueira, J.; Alvarenga, A. D.; Sóñora, D.; Sefat, A. S.; Salem-Sugui, S., Jr.

    2017-12-01

    Isothermal magnetic field dependence of magnetization and magnetic relaxation measurements were performed for the H\\parallel {{c}} axis on a single crystal of Ba(Fe0.935 Co0.065)2As2 pnictide superconductor having T c = 21.7 K. The second magnetization peak (SMP) for each isothermal M(H) was observed in a wide temperature range from T c to the lowest temperature of measurement (2 K). The magnetic field dependence of relaxation rate R(H), showed a peak (H spt) between H on (onset of SMP in M(H)) and H p (peak field of SMP in M(H)), which is likely to be related to a vortex-lattice structural phase transition, as suggested in the literature for a similar sample. In addition, the magnetic relaxation measured for magnetic fields near H spt showed some noise, which might be the signature of the structural phase transition of the vortex lattice. Analysis of the magnetic relaxation data using Maley’s criterion and the collective pinning theory suggested that the SMP in the sample was due to the collective (elastic) to plastic creep crossover, which was also accompanied by a rhombic to square vortex lattice phase transition. Analysis of the pinning force density suggested a single dominating pinning mechanism in the sample, which did not showing the usual δ {l} and δ {T}{{c}} nature of pinning. The critical current density (J c), estimated using the Bean critical state model, was found to be 5 × 105 A cm- 2 at 2 K in the zero magnetic field limit. Surprisingly, the maximum of the pinning force density was not responsible for the maximum value of the critical current density in the sample.

  20. Toxicity evaluation of natural samples from the vicinity of rice fields using two trophic levels.

    PubMed

    Marques, Catarina R; Pereira, Ruth; Gonçalves, Fernando

    2011-09-01

    An ecotoxicological screening of environmental samples collected in the vicinity of rice fields followed a combination of physical and chemical measurements and chronic bioassays with two freshwater trophic levels (microalgae: Pseudokirchneriella subcapitata and Chlorella vulgaris; daphnids: Daphnia longispina and Daphnia magna). As so, water and sediment/soil elutriate samples were obtained from three sites: (1) in a canal reach crossing a protected wetland upstream, (2) in a canal reach surrounded by rice fields and (3) in a rice paddy. The sampling was performed before and during the rice culture. During the rice cropping, the whole system quality decreased comparatively to the situation before that period (e.g. nutrient overload, the presence of pesticides in elutriates from sites L2 and L3). This was reinforced by a significant inhibition of both microalgae growth, especially under elutriates. Contrary, the life-history traits of daphnids were significantly stimulated with increasing concentrations of water and elutriates, for both sampling periods.

  1. The Impact of Soil Sampling Errors on Variable Rate Fertilization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    R. L. Hoskinson; R C. Rope; L G. Blackwood

    2004-07-01

    Variable rate fertilization of an agricultural field is done taking into account spatial variability in the soil’s characteristics. Most often, spatial variability in the soil’s fertility is the primary characteristic used to determine the differences in fertilizers applied from one point to the next. For several years the Idaho National Engineering and Environmental Laboratory (INEEL) has been developing a Decision Support System for Agriculture (DSS4Ag) to determine the economically optimum recipe of various fertilizers to apply at each site in a field, based on existing soil fertility at the site, predicted yield of the crop that would result (and amore » predicted harvest-time market price), and the current costs and compositions of the fertilizers to be applied. Typically, soil is sampled at selected points within a field, the soil samples are analyzed in a lab, and the lab-measured soil fertility of the point samples is used for spatial interpolation, in some statistical manner, to determine the soil fertility at all other points in the field. Then a decision tool determines the fertilizers to apply at each point. Our research was conducted to measure the impact on the variable rate fertilization recipe caused by variability in the measurement of the soil’s fertility at the sampling points. The variability could be laboratory analytical errors or errors from variation in the sample collection method. The results show that for many of the fertility parameters, laboratory measurement error variance exceeds the estimated variability of the fertility measure across grid locations. These errors resulted in DSS4Ag fertilizer recipe recommended application rates that differed by up to 138 pounds of urea per acre, with half the field differing by more than 57 pounds of urea per acre. For potash the difference in application rate was up to 895 pounds per acre and over half the field differed by more than 242 pounds of potash per acre. Urea and potash differences accounted for almost 87% of the cost difference. The sum of these differences could result in a $34 per acre cost difference for the fertilization. Because of these differences, better analysis or better sampling methods may need to be done, or more samples collected, to ensure that the soil measurements are truly representative of the field’s spatial variability.« less

  2. Mycobacterium avium subsp. paratuberculosis from free-ranging deer and rabbits surrounding Minnesota dairy herds

    PubMed Central

    2005-01-01

    Abstract The objectives of this study were to estimate the prevalence of Mycobacterium avium subsp. paratuberculosis (MAP) among deer and rabbits surrounding infected and noninfected Minnesota dairy farms using fecal culture, and to describe the frequency that farm management practices were used that could potentially lead to transmission of infection between these species. Fecal samples from cows and the cow environment were collected from 108 Minnesota dairy herds, and fecal pellets from free-ranging white-tailed deer and eastern cottontail rabbits were collected from locations surrounding 114 farms; all samples were tested using bacterial culture. In addition, a questionnaire was administered to 114 herd owners. Sixty-two percent of the dairy herds had at least 1 positive fecal pool or environmental sample. A total of 218 rabbit samples were collected from 90% of the herds, and 309 deer samples were collected from 47% of the herds. On 2 (4%) of the farms sampled, 1 deer fecal sample was MAP positive. Both farms had samples from the cow fecal pool and cow environment that were positive by culture. On 2 (2%) other farms, 1 rabbit fecal sample was positive by culture to MAP, with one of these farms having positive cow fecal pools and cow environmental samples. Pasture was used on 79% of the study farms as a grazing area for cattle, mainly for dry cows (75%) and bred or prebred heifers (87%). Of the 114 farms, 88 (77%) provided access to drylot for their cattle, mainly for milking cows (77/88; 88%) and bred heifers (87%). Of all study farms, 90 (79%) used some solid manure broadcasting on their crop fields. Of all 114 farms, the estimated probability of daily physical contact between cattle manure and deer or rabbits was 20% and 25%, respectively. Possible contact between cattle manure and deer or rabbits was estimated to occur primarily from March through December. The frequency of pasture or drylot use and manure spreading on crop fields may be important risk factors for transmission of MAP among dairy cattle, deer, and rabbits. Although the MAP prevalence among rabbits and deer is low, their role as MAP reservoirs should be considered. PMID:15745220

  3. Sample Return Robot Centennial Challenge

    NASA Image and Video Library

    2012-06-15

    University of Waterloo (Canada) Robotics Team members test their robot on the practice field one day prior to the NASA-WPI Sample Return Robot Centennial Challenge, Friday, June 15, 2012 at the Worcester Polytechnic Institute in Worcester, Mass. Teams will compete for a $1.5 million NASA prize to build an autonomous robot that can identify, collect and return samples. NASA needs autonomous robotic capability for future planetary exploration. Photo Credit: (NASA/Bill Ingalls)

  4. Sample Return Robot Centennial Challenge

    NASA Image and Video Library

    2012-06-14

    A University of Waterloo Robotics Team member tests their robot on the practice field two days prior to the NASA-WPI Sample Return Robot Centennial Challenge, Thursday, June 14, 2012 at the Worcester Polytechnic Institute in Worcester, Mass. Teams will compete for a $1.5 million NASA prize to build an autonomous robot that can identify, collect and return samples. NASA needs autonomous robotic capability for future planetary exploration. Photo Credit: (NASA/Bill Ingalls)

  5. INNOVATIVE TECHNOLOGY VERIFICATION REPORT XRF ...

    EPA Pesticide Factsheets

    The Rigaku ZSX Mini II (ZSX Mini II) XRF Services x-ray fluorescence (XRF) analyzer was demon-strated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation (SITE) Program. The field portion of the demonstration was conducted in January 2005 at the Kennedy Athletic, Recreational and Social Park (KARS) at Kennedy Space Center on Merritt Island, Florida. The demonstration was designed to collect reliable performance and cost data for the ZSX Mini II analyzer and seven other commercially available XRF instruments for measuring trace elements in soil and sediment. The performance and cost data were evaluated to document the relative performance of each XRF instrument. This innovative technology verification report describes the objectives and the results of that evaluation and serves to verify the performance and cost of the ZSX Mini II analyzer. Separate reports have been prepared for the other XRF instruments that were evaluated as part of the demonstration. The objectives of the evaluation included determining each XRF instrument’s accuracy, precision, sample throughput, and tendency for matrix effects. To fulfill these objectives, the field demonstration incorporated the analysis of 326 prepared samples of soil and sediment that contained 13 target elements. The prepared samples included blends of environmental samples from nine different sample collection sites as well as spiked samples with certified element con

  6. INNOVATIVE TECHNOLOGY VERIFICATION REPORT XRF ...

    EPA Pesticide Factsheets

    The Rontec PicoTAX x-ray fluorescence (XRF) analyzer was demonstrated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation (SITE) Program. The field portion of the demonstration was conducted in January 2005 at the Kennedy Athletic, Recreational and Social Park (KARS) at Kennedy Space Center on Merritt Island, Florida. The demonstration was designed to collect reliable performance and cost data for the PicoTAX analyzer and seven other commercially available XRF instruments for measuring trace elements in soil and sediment. The performance and cost data were evaluated to document the relative performance of each XRF instrument. This innovative technology verification report describes the objectives and the results of that evaluation and serves to verify the performance and cost of the PicoTAX analyzer. Separate reports have been prepared for the other XRF instruments that were evaluated as part of the demonstration. The objectives of the evaluation included determining each XRF instrument’s accuracy, precision, sample throughput, and tendency for matrix effects. To fulfill these objectives, the field demonstration incorporated the analysis of 326 prepared samples of soil and sediment that contained 13 target elements. The prepared samples included blends of environmental samples from nine different sample collection sites as well as spiked samples with certified element concentrations. Accuracy was assessed by c

  7. INNOVATIVE TECHNOLOGY VERIFICATION REPORT XRF ...

    EPA Pesticide Factsheets

    The Niton XLt 700 Series (XLt) XRF Services x-ray fluorescence (XRF) analyzer was demonstrated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation (SITE) Program. The field portion of the demonstration was conducted in January 2005 at the Kennedy Athletic, Recreational and Social Park (KARS) at Kennedy Space Center on Merritt Island, Florida. The demonstration was designed to collect reliable performance and cost data for the XLt analyzer and seven other commercially available XRF instruments for measuring trace elements in soil and sediment. The performance and cost data were evaluated to document the relative performance of each XRF instrument. This innovative technology verification report describes the objectives and the results of that evaluation and serves to verify the performance and cost of the XLt analyzer. Separate reports have been prepared for the other XRF instruments that were evaluated as part of the demonstration. The objectives of the evaluation included determining each XRF instrument’s accuracy, precision, sample throughput, and tendency for matrix effects. To fulfill these objectives, the field demonstration incorporated the analysis of 326 prepared samples of soil and sediment that contained 13 target elements. The prepared samples included blends of environmental samples from nine different sample collection sites as well as spiked samples with certified element concentrations. Accuracy

  8. INNOVATIVE TECHNOLOGY VERIFICATION REPORT XRF ...

    EPA Pesticide Factsheets

    The Oxford ED2000 x-ray fluorescence (XRF) analyzer was demonstrated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation (SITE) Program. The field portion of the demonstration was conducted in January 2005 at the Kennedy Athletic, Recreational and Social Park (KARS) at Kennedy Space Center on Merritt Island, Florida. The demonstration was designed to collect reliable performance and cost data for the ED2000 analyzer and seven other commercially available XRF instruments for measuring trace elements in soil and sediment. The performance and cost data were evaluated to document the relative performance of each XRF instrument. This innovative technology verification report describes the objectives and the results of that evaluation and serves to verify the performance and cost of the ED2000 analyzer. Separate reports have been prepared for the other XRF instruments that were evaluated as part of the demonstration. The objectives of the evaluation included determining each XRF instrument’s accuracy, precision, sample throughput, and tendency for matrix effects. To fulfill these objectives, the field demonstration incorporated the analysis of 326 prepared samples of soil and sediment that contained 13 target elements. The prepared samples included blends of environmental samples from nine different sample collection sites as well as spiked samples with certified element concentrations. Accuracy was assessed by com

  9. Effects of septic-tank effluent on ground-water quality in northern Williamson County and southern Davidson County, Tennessee

    USGS Publications Warehouse

    Hanchar, D.W.

    1991-01-01

    An investigation of the potential contamination of ground water from septic tank systems blasted in bedrock in Williamson and Davidson Counties, Tennessee, was conducted during 1988-89. Water samples were collected from domestic and observation wells, springs, and surface-water sites in a residential subdivision in the northern part of Williamson County near Nashville. The subdivision has a high density of septic-tank field lines installed into blasted bedrock Water samples also were collected from a well located in an area of Davidson County where field lines were installed in 5 feet of soil. Samples were analyzed for major inorganic constituents, nutrients, total organic carbon, optical brighteners, and bacteria. Although results of analyses of water samples from wells indicate no effect of septic-tank effluent on ground-water quality at these sites, water from two springs located downgradient from the subdivision had slightly larger concentrations of nitrite plus nitrate (2.2 and 2.7 milligrams per liter N), and much larger concentrations of fecal coliform and fecal streptococci bacteria (2,000 to 3,200 and 700 to 900 colonies per 100 milliliters of sample, respectively), than other wells and springs sampled during 1988. Water from one of these springs contained optical brighteners, which indicates that septic-tank effluent is affecting ground-water quality.

  10. INNOVATIVE TECHNOLOGY VERIFICATION REPORT XRF ...

    EPA Pesticide Factsheets

    The Innov-X XT400 Series (XT400) x-ray fluorescence (XRF) analyzer was demonstrated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation (SITE) Program. The field portion of the demonstration was conducted in January 2005 at the Kennedy Athletic, Recreational and Social Park (KARS) at Kennedy Space Center on Merritt Island, Florida. The demonstration was designed to collect reliable performance and cost data for the XT400 analyzer and seven other commercially available XRF instruments for measuring trace elements in soil and sediment. The performance and cost data were evaluated to document the relative performance of each XRF instrument. This innovative technology verification report describes the objectives and the results of that evaluation and serves to verify the performance and cost of the XT400 analyzer. Separate reports have been prepared for the other XRF instruments that were evaluated as part of the demonstration. The objectives of the evaluation included determining each XRF instrument’s accuracy, precision, sample throughput, and tendency for matrix effects. To fulfill these objectives, the field demonstration incorporated the analysis of 326 prepared samples of soil and sediment that contained 13 target elements. The prepared samples included blends of environmental samples from nine different sample collection sites as well as spiked samples with certified element concentrations. Accuracy was as

  11. Evaluation of the impact of RNA preservation methods of spiders for de novo transcriptome assembly.

    PubMed

    Kono, Nobuaki; Nakamura, Hiroyuki; Ito, Yusuke; Tomita, Masaru; Arakawa, Kazuharu

    2016-05-01

    With advances in high-throughput sequencing technologies, de novo transcriptome sequencing and assembly has become a cost-effective method to obtain comprehensive genetic information of a species of interest, especially in nonmodel species with large genomes such as spiders. However, high-quality RNA is essential for successful sequencing, and sample preservation conditions require careful consideration for the effective storage of field-collected samples. To this end, we report a streamlined feasibility study of various storage conditions and their effects on de novo transcriptome assembly results. The storage parameters considered include temperatures ranging from room temperature to -80°C; preservatives, including ethanol, RNAlater, TRIzol and RNAlater-ICE; and sample submersion states. As a result, intact RNA was extracted and assembly was successful when samples were preserved at low temperatures regardless of the type of preservative used. The assemblies as well as the gene expression profiles were shown to be robust to RNA degradation, when 30 million 150-bp paired-end reads are obtained. The parameters for sample storage, RNA extraction, library preparation, sequencing and in silico assembly considered in this work provide a guideline for the study of field-collected samples of spiders. © 2015 John Wiley & Sons Ltd.

  12. Effects of three phosphate industrial sites on ground-water quality in central Florida, 1979 to 1980

    USGS Publications Warehouse

    Miller, R.L.; Sutcliffe, Horace

    1984-01-01

    Geologic, hydrologic, and water quality data and information on test holes collected in the vicinity of gypsum stack complexes at two phosphate chemical plants and one phosphatic clayey waste disposal pond at a phosphate mine and beneficiation plant in central Florida are presented. The data were collected from September 1979 to October 1980 at the AMAX Phosphate, Inc. chemical plant, Piney Point; the USS Agri-Chemicals chemical plant, Bartow; and the International Minerals and Chemical Corporation Clear Springs mine, Bartow. Approximately 5,400 field and laboratory water quality determinations on water samples collected from about 100 test holes and 28 surface-water , 5 rainfall, and other sampling sites at phosphate industry beneficiation and chemical plant waste disposal operations are tabulated. Maps are included to show sampling sites. (USGS)

  13. Water-quality and hydrogeologic data for three phosphate industry waste-disposal sites in central Florida, 1979-80

    USGS Publications Warehouse

    Miller, Ronald L.; Sutcliffe, Horace

    1982-01-01

    This report is a complilation of geologic, hydrologic, and water-quality data and information on test holes collected in the vicinity of gypsum stack complexes at two phosphate chemical plants and one phosphatic clayey waste disposal pond at a phosphate mine and beneficiation plant in central Florida. The data were collected from September 1979 to October 1980 at thee AMAX Phosphate, Inc., chemical plant, Piney Point; the USS AgriChemicals chemical plant, Bartow; and the International Minerals and Chemical Corporation Clear Springs mine, Bartow. Approximmmtely 5,400 field and laboratory water-quality determinations on water samples were collected from about 78 test holes and 31 surface-water, rainfall, and other sampling sites at phosphate industry beneficiation and chemical plant waste-disposal operations. Maps show locations of sampling sites. (USGS)

  14. Water-quality sampling by the U.S. Geological Survey-Standard protocols and procedures

    USGS Publications Warehouse

    Wilde, Franceska D.

    2010-01-01

    Thumbnail of and link to report PDF (1.0 MB) The U.S. Geological Survey (USGS) develops the sampling procedures and collects the data necessary for the accurate assessment and wise management of our Nation's surface-water and groundwater resources. Federal and State agencies, water-resource regulators and managers, and many organizations and interested parties in the public and private sectors depend on the reliability, timeliness, and integrity of the data we collect and the scientific soundness and impartiality of our data assessments and analysis. The standard data-collection methods uniformly used by USGS water-quality personnel are peer reviewed, kept up-to-date, and published in the National Field Manual for the Collection of Water-Quality Data (http://pubs.water.usgs.gov/twri9A/).

  15. In vitro adaptation of Plasmodium falciparum reveal variations in cultivability.

    PubMed

    White, John; Mascarenhas, Anjali; Pereira, Ligia; Dash, Rashmi; Walke, Jayashri T; Gawas, Pooja; Sharma, Ambika; Manoharan, Suresh Kumar; Guler, Jennifer L; Maki, Jennifer N; Kumar, Ashwani; Mahanta, Jagadish; Valecha, Neena; Dubhashi, Nagesh; Vaz, Marina; Gomes, Edwin; Chery, Laura; Rathod, Pradipsinh K

    2016-01-22

    Culture-adapted Plasmodium falciparum parasites can offer deeper understanding of geographic variations in drug resistance, pathogenesis and immune evasion. To help ground population-based calculations and inferences from culture-adapted parasites, the complete range of parasites from a study area must be well represented in any collection. To this end, standardized adaptation methods and determinants of successful in vitro adaption were sought. Venous blood was collected from 33 P. falciparum-infected individuals at Goa Medical College and Hospital (Bambolim, Goa, India). Culture variables such as whole blood versus washed blood, heat-inactivated plasma versus Albumax, and different starting haematocrit levels were tested on fresh blood samples from patients. In vitro adaptation was considered successful when two four-fold or greater increases in parasitaemia were observed within, at most, 33 days of attempted culture. Subsequently, parasites from the same patients, which were originally cryopreserved following blood draw, were retested for adaptability for 45 days using identical host red blood cells (RBCs) and culture media. At a new endemic area research site, ~65% of tested patient samples, with varied patient history and clinical presentation, were successfully culture-adapted immediately after blood collection. Cultures set up at 1% haematocrit and 0.5% Albumax adapted most rapidly, but no single test condition was uniformly fatal to culture adaptation. Success was not limited by low patient parasitaemia nor by patient age. Some parasites emerged even after significant delays in sample processing and even after initiation of treatment with anti-malarials. When 'day 0' cryopreserved samples were retested in parallel many months later using identical host RBCs and media, speed to adaptation appeared to be an intrinsic property of the parasites collected from individual patients. Culture adaptation of P. falciparum in a field setting is formally shown to be robust. Parasites were found to have intrinsic variations in adaptability to culture conditions, with some lines requiring longer attempt periods for successful adaptation. Quantitative approaches described here can help describe phenotypic diversity of field parasite collections with precision. This is expected to improve population-based extrapolations of findings from field-derived fresh culture-adapted parasites to broader questions of public health importance.

  16. Environmental assessment of creosote-treated pilings in the marine environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Butala, J.H.; Webb, D.A.; Jop, K.M.

    1995-12-31

    A comprehensive ecological risk assessment was conducted to evaluate the environmental impact of creosote-treated pilings in the marine environment at Moss Landing Harbor, Moss Landing, California. Four areas of investigation comprising the risk assessment were (1) evaluation of environmental conditions around existing creosote-treated pilings (2) investigating effects related to restoration of pilings (3) assessing creosote migration into surrounding environment, one year after pile-driving and (4) confirmation of creosote toxicity in laboratory studies. Biological and chemical evaluation of the impact of creosote-treated pilings was conducted on surface sheen, water column and sediment samples collected at Moss Landing Harbor. Water samples (surfacemore » sheen, water column and sediment pore water) were evaluated using short-term chronic exposures with Mysidopsis bahia, while bulk sediment samples were evaluated with 10-day sediment toxicity tests with Ampelisca abdita. Samples of surface, column water and sediment were analyzed for the constituents of creosote by GC mass spectrometry. In addition, a sample of neat material used to preserve treated pilings represented a reference for the polyaromatic hydrocarbons. Verification of organism response and analyses of field collected samples was performed by conducting 10-day A. abdita sediment and 7-day M. bahia elutriate exposures with creosote applied to clean sediment collected at Moss Landing, Evaluations were also performed to determine the effects of photoinduced toxicity on test organisms exposed to PAHs. The biological and analytical results of the field and laboratory exposures are being used to evaluate and determine risk of creosote-treated pilings on the marine environment.« less

  17. Development and field application of a 6-bottle serial gas-tight fluid sampler for collecting seafloor cold seep and hydrothermal vent fluids with autonomous operation capability

    NASA Astrophysics Data System (ADS)

    Wu, S.; Ding, K.; Yang, C.; Seyfried, W. E., Jr.; Tan, C.; Schaen, A. T.; Luhmann, A. J.

    2014-12-01

    A 6-bottle serial gas-tight sampler (so-called "six-shooter") was developed for application with deep-sea vent fluids. The new device is composed of a custom-made 6-channel valve manifold and six sampling bottles which are circularly distributed around the valve manifold. Each valve channel consists of a high-pressure titanium cartridge valve and a motor-driven actuator. A sampling snorkel is connected to the inlet of the manifold that delivers the incoming fluid to different bottles. Each sampling bottle has a 160 ml-volume chamber and an accumulator chamber inside where compressed nitrogen is used to maintain the sample at near in-situ pressure. An electronics chamber that is located at the center of the sampler is used to carry out all sampling operations, autonomously, if desired. The sampler is of a compact circular configuration with a diameter of 26 cm and a length of 54 cm. During the SVC cruise AT 26-12, the sampler was deployed by DSV2 Alvin at a cold seep site MC036 with a depth of 1090 m in the Gulf of Mexico. The sampler collected fluid samples automatically following the tidal cycle to monitor the potential impact of the tide cycle on the fluid chemistry of cold seep in a period of two day. During the cruise AT 26-17, the sampler was used with newly upgraded DSV2 Alvin three times at the hydrothermal vent sites along Axial Seamount and Main Endeavor Field on Juan de Fuca Ridge. During a 4-day deployment at Anemone diffuse site (Axial Caldera), the sampler was set to work in an autonomous mode to collect fluid samples according to the preset interval. During other dives, the sampler was manually controlled via ICL (Inductively Coupled Link) communication through the hull. Gas-tight fluid samples were collected from different hydrothermal vents with temperatures between 267 ℃ and 335 ℃ at the depth up to 2200 m. The field results indicate unique advantages of the design. It can be deployed in extended time period with remote operation or working autonomously taking gas-tight fluid samples. If used with HOV or ROV, it will reduce basket space occupation and ICL communication cables compared to traditional single-bottle gas-tight samplers. This time serial gas-tight fluid sampler will be further developed into a 36 bottle system for remote operation with seafloor cabled observatory.

  18. Employment Opportunities in Applied Biological and Agricultural Occupations in the Metropolitan Area of Chicago.

    ERIC Educational Resources Information Center

    Thomas, Hollie B.; Neavill, Arthur

    Based on questionnaire data collected from a sample of employers, this phase of a larger research project ascertained employment opportunities in the area of applied biological and agricultural occupations in the metropolitan area of Chicago. Specific fields of business surveyed by stratified random sample were animal care, animal health care,…

  19. NHEXAS PHASE I MARYLAND STUDY--STANDARD OPERATING PROCEDURE FOR CHAIN-OF-CUSTODY AND SAMPLE TRACKING (G04)

    EPA Science Inventory

    The purpose of the SOP is to establish the normal procedures for ensuring data chain-of-custody and data tracking. The chain-of-custody form included in this SOP is the standard form to be used for all data collected in the field. Keywords: samples; custody; records.

    The Nat...

  20. DETERMINATION OF SULFUR DIOXIDE, NITROGEN OXIDES, AND CARBON DIOXIDE IN EMISSIONS FROM ELECTRIC UTILITY PLANTS BY ALKALINE PERMANGANATE SAMPLING AND ION CHROMATOGRAPHY

    EPA Science Inventory

    A manual 24-h integrated method for determining SO2, NOx, and CO2 in emissions from electric utility plants was developed and field tested downstream from an SO2 control system. Samples were collected in alkaline potassium permanganate solution contained in restricted-orifice imp...

  1. Assessment of common soybean-infecting viruses in Ohio, USA, through multisite sampling and high-throughput sequencing

    USDA-ARS?s Scientific Manuscript database

    To assess the scope of virus disease problems of soybean in Ohio, USA, a survey was conducted during 2011 and 2012 soybean growing seasons. A total of 259 samples were collected from 80 soybean fields distributed in 42 Ohio counties, accounting for more than 90% of major soybean-growing counties in ...

  2. Work plan for focused feasibility study of the toxic burning pits area at J-Field, Aberdeen Proving Ground, Maryland

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Biang, C.; Benioff, P.; Martino, L.

    1995-03-01

    The Environmental Management Division (EMD) of Aberdeen Proving Ground (APG), Maryland, is conducting a remedial investigation and feasibility study (RI/FS) of the J-Field area at APG pursuant to the Comprehensive Environmental Response, Compensation, and Liability Act, as amended (CERCIA). J-Field is within the Edgewood Area of APG in Harford County, Maryland. Since World War II, activities in the Edgewood Area have included the development, manufacture, testing, and destruction of chemical agents and munitions. These materials were destroyed at J-Field by open burning and open detonation (OB/OD). Considerable archival information about J-Field exists as a result of efforts by APG staffmore » to characterize the hazards associated with the site. Contamination of J-Field was first detected during an environmental survey of the Edgewood Area conducted in 1977 and 1978 by the US Army Toxic and Hazardous Materials Agency (USATHAMA)(predecessor to the US Army Environmental Center). As part of a subsequent USATHAMA environmental survey, 11 wells were installed and sampled at J-Field. Contamination at J-Field was also detected during a munitions disposal survey conducted by Princeton Aqua Science in 1983. The Princeton Aqua Science investigation involved the installation and sampling of nine wells and the collection and analysis of surficial and deep composite soil samples. In 1986, a Resource Conservation and Recovery Act (RCRA) permit (MD3-21-0021355) requiring a basewide RCRA Facility Assessment (RFA) and a hydrogeologic assessment of J-Field was issued by the US Environmental Protection Agency (EPA). In 1987, the US Geological Survey (USGS) began a two-phased hydrogeologic assessment in which data were collected to model groundwater flow at J-Field. Soil gas investigations were conducted, several well clusters were installed, a groundwater flow model was developed, and groundwater and surface water monitoring programs were established that continue today-« less

  3. Study and optimization of key parameters of a laser ablation ion mobility spectrometer

    NASA Astrophysics Data System (ADS)

    Ni, Kai; Li, Jianan; Tang, Binchao; Shi, Yuan; Yu, Quan; Qian, Xiang; Wang, Xiaohao

    2016-11-01

    Ion Mobility Spectrometry (IMS), having an advantage in real-time and on-line detection, is an atmospheric pressure detecting technique. LA-IMS (Laser Ablation Ion Mobility Spectrometry) uses Nd-YAG laser as ionization source, whose energy is high enough to ionize metal. In this work, we tested the signal in different electric field intensity by a home-made ion mobility spectrometer, using silicon wafers the sample. The transportation of metal ions was match with the formula: Td = d/K • 1/E, when the electric field intensity is greater than 350v/cm. The relationship between signal intensity and collection angle (the angle between drift tube and the surface of the sample) was studied. With the increasing of the collection angle, signal intensity had a significant increase; while the variation of incident angle of the laser had no significant influence. The signal intensity had a 140% increase when the collection angle varied from 0 to 45 degree, while the angle between the drift tube and incident laser beam keeping the same as 90 degree. The position of ion gate in LA-IMS(Laser Ablation Ion Mobility Spectrometry) is different from the traditional ones for the kinetic energy of the ions is too big, if the distance between ion gate and sampling points less than 2.5cm the ion gate will not work, the ions could go through ion gate when it closed. The SNR had been improved by define the signal when the ion gate is closed as background signal, the signal noise including shock wave and electrical field perturbation produced during the interaction between laser beam and samples is eliminated when the signal that the ion gate opened minus the background signal.

  4. Crop Pollination Exposes Honey Bees to Pesticides Which Alters Their Susceptibility to the Gut Pathogen Nosema ceranae

    PubMed Central

    Pettis, Jeffery S.; Lichtenberg, Elinor M.; Andree, Michael; Stitzinger, Jennie; Rose, Robyn; vanEngelsdorp, Dennis

    2013-01-01

    Recent declines in honey bee populations and increasing demand for insect-pollinated crops raise concerns about pollinator shortages. Pesticide exposure and pathogens may interact to have strong negative effects on managed honey bee colonies. Such findings are of great concern given the large numbers and high levels of pesticides found in honey bee colonies. Thus it is crucial to determine how field-relevant combinations and loads of pesticides affect bee health. We collected pollen from bee hives in seven major crops to determine 1) what types of pesticides bees are exposed to when rented for pollination of various crops and 2) how field-relevant pesticide blends affect bees’ susceptibility to the gut parasite Nosema ceranae. Our samples represent pollen collected by foragers for use by the colony, and do not necessarily indicate foragers’ roles as pollinators. In blueberry, cranberry, cucumber, pumpkin and watermelon bees collected pollen almost exclusively from weeds and wildflowers during our sampling. Thus more attention must be paid to how honey bees are exposed to pesticides outside of the field in which they are placed. We detected 35 different pesticides in the sampled pollen, and found high fungicide loads. The insecticides esfenvalerate and phosmet were at a concentration higher than their median lethal dose in at least one pollen sample. While fungicides are typically seen as fairly safe for honey bees, we found an increased probability of Nosema infection in bees that consumed pollen with a higher fungicide load. Our results highlight a need for research on sub-lethal effects of fungicides and other chemicals that bees placed in an agricultural setting are exposed to. PMID:23894612

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ottesen, Elizabeth A.; Marin, Roman; Preston, Christina M.

    Planktonic microbial activity and community structure is dynamic, and can change dramatically on time scales of hours to days. Yet for logistical reasons, this temporal scale is typically undersampled in the marine environment. In order to facilitate higher-resolution, long-term observation of microbial diversity and activity, we developed a protocol for automated collection and fixation of marine microbes using the Environmental Sample Processor (ESP) platform. The protocol applies a preservative (RNALater) to cells collected on filters, for long-term storage and preservation of total cellular RNA. Microbial samples preserved using this protocol yielded high-quality RNA after 30 days of storage at roommore » temperature, or onboard the ESP at in situ temperatures. Pyrosequencing of complementary DNA libraries generated from ESP-collected and preserved samples yielded transcript abundance profiles nearly indistinguishable from those derived from conventionally treated replicate samples. To demonstrate the utility of the method, we used a moored ESP to remotely and autonomously collect Monterey Bay seawater for metatranscriptomic analysis. Community RNA was extracted and pyrosequenced from samples collected at four time points over the course of a single day. In all four samples, the oxygenic photoautotrophs were predominantly eukaryotic, while the bacterial community was dominated by Polaribacter-like Flavobacteria and a Rhodobacterales bacterium sharing high similarity with Rhodobacterales sp. HTCC2255. However, each time point was associated with distinct species abundance and gene transcript profiles. These laboratory and field tests confirmed that autonomous collection and preservation is a feasible and useful approach for characterizing the expressed genes and environmental responses of marine microbial communities.« less

  6. Use of Body-Mounted Cameras to Enhance Data Collection: An Evaluation of Two Arthropod Sampling Techniques.

    PubMed

    Hagler, James R; Thompson, Alison L; Stefanek, Melissa A; Machtley, Scott A

    2018-03-01

    A study was conducted that compared the effectiveness of a sweepnet versus a vacuum suction device for collecting arthropods in cotton. The study differs from previous research in that body-mounted action cameras (B-MACs) were used to record the activity of the person conducting the arthropod collections. The videos produced by the B-MACs were then analyzed with behavioral event recording software to quantify various aspects of the sampling process. The sampler's speed and the number of sampling sweeps or vacuum suctions taken over a fixed distance (12.2 m) of cotton were two of the more significant sampling characteristics quantified for each method. The arthropod counts obtained, combined with the analyses of the videos, enabled us to estimate arthropod sampling efficiency for each technique based on fixed distance, time, and sample unit measurements. Data revealed that the vacuuming was the most precise method for collecting arthropods in the relatively small cotton research plots. However, data also indicates that the sweepnet method would be more efficient for collecting most of the cotton-dwelling arthropod taxa, especially if the sampler could continuously sweep for at least 1 min or ≥80 m (e.g., in larger research plots). The B-MACs are inexpensive and non-cumbersome, the video images generated are outstanding, and they can be archived to provide permanent documentation of a research project. The methods described here could be useful for other types of field-based research to enhance data collection efficiency.

  7. Epistemological Issues in Astronomy Education Research: How Big of a Sample is "Big Enough"?

    NASA Astrophysics Data System (ADS)

    Slater, Stephanie; Slater, T. F.; Souri, Z.

    2012-01-01

    As astronomy education research (AER) continues to evolve into a sophisticated enterprise, we must begin to grapple with defining our epistemological parameters. Moreover, as we attempt to make pragmatic use of our findings, we must make a concerted effort to communicate those parameters in a sensible way to the larger astronomical community. One area of much current discussion involves a basic discussion of methodologies, and subsequent sample sizes, that should be considered appropriate for generating knowledge in the field. To address this question, we completed a meta-analysis of nearly 1,000 peer-reviewed studies published in top tier professional journals. Data related to methodologies and sample sizes were collected from "hard science” and "human science” journals to compare the epistemological systems of these two bodies of knowledge. Working back in time from August 2011, the 100 most recent studies reported in each journal were used as a data source: Icarus, ApJ and AJ, NARST, IJSE and SciEd. In addition, data was collected from the 10 most recent AER dissertations, a set of articles determined by the science education community to be the most influential in the field, and the nearly 400 articles used as reference materials for the NRC's Taking Science to School. Analysis indicates these bodies of knowledge have a great deal in common; each relying on a large variety of methodologies, and each building its knowledge through studies that proceed from surprisingly low sample sizes. While both fields publish a small percentage of studies with large sample sizes, the vast majority of top tier publications consist of rich studies of a small number of objects. We conclude that rigor in each field is determined not by a circumscription of methodologies and sample sizes, but by peer judgments that the methods and sample sizes are appropriate to the research question.

  8. Surface-water-quality assessment of the upper Illinois River Basin in Illinois, Indiana, and Wisconsin; fixed-station network and selected water-quality data for April 1987-September 1990

    USGS Publications Warehouse

    Sullivan, Daniel J.; Blanchard, Stephen F.

    1994-01-01

    This report describes and presents the sampling design, methods, quality assurance methods and results, and information on how to obtain data collected at eight fixed stations in the upper Illinois River Basin as part of the pilot phase of the National Water-Quality Assessment program. Data were collected monthly from April 1987-August l990; these data were supplemented with data collected during special events, including high and low flows. Each fixed station represents a cross section at which the transport of selected dissolved and suspended materials can be computed. Samples collected monthly and during special events were analyzed for concentrations of major ions, nutrients, trace elements, organic carbon, chlorophyll-a, suspended sediment, and other constituents. Field measurements of water temperature, pH, dissolved oxygen, specific conductance, and indicator bacteria also were made at each site. Samples of suspended sediment were analyzed for concentrations of major ions and trace elements. In addition, samples were analyzed seasonally for concentrations of antimony, bromide, molybdenum, and the radionuclides gross alpha and gross beta.

  9. Design and development of a highly sensitive, field portable plasma source instrument for on-line liquid stream monitoring and real-time sample analysis

    NASA Astrophysics Data System (ADS)

    Duan, Yixiang; Su, Yongxuan; Jin, Zhe; Abeln, Stephen P.

    2000-03-01

    The development of a highly sensitive, field portable, low-powered instrument for on-site, real-time liquid waste stream monitoring is described in this article. A series of factors such as system sensitivity and portability, plasma source, sample introduction, desolvation system, power supply, and the instrument configuration, were carefully considered in the design of the portable instrument. A newly designed, miniature, modified microwave plasma source was selected as the emission source for spectroscopy measurement, and an integrated small spectrometer with a charge-coupled device detector was installed for signal processing and detection. An innovative beam collection system with optical fibers was designed and used for emission signal collection. Microwave plasma can be sustained with various gases at relatively low power, and it possesses high detection capabilities for both metal and nonmetal pollutants, making it desirable to use for on-site, real-time, liquid waste stream monitoring. An effective in situ sampling system was coupled with a high efficiency desolvation device for direct-sampling liquid samples into the plasma. A portable computer control system is used for data processing. The new, integrated instrument can be easily used for on-site, real-time monitoring in the field. The system possesses a series of advantages, including high sensitivity for metal and nonmetal elements; in situ sampling; compact structure; low cost; and ease of operation and handling. These advantages will significantly overcome the limitations of previous monitoring techniques and make great contributions to environmental restoration and monitoring.

  10. Mercury in ground water, septage, leach-field effluent, and soils in residential areas, New Jersey coastal plain

    USGS Publications Warehouse

    Barringer, J.L.; Szabo, Z.; Schneider, D.; Atkinson, W.D.; Gallagher, R.A.

    2006-01-01

    Water samples were collected from domestic wells at an unsewered residential area in Gloucester County, New Jersey where mercury (Hg) concentrations in well water were known to exceed the USEPA maximum contaminant level (MCL) of 2000 ng/L. This residential area (the CSL site) is representative of more than 70 such areas in southern New Jersey where about 600 domestic wells, sampled previously by State and county agencies, yielded water containing Hg at concentrations that exceed the MCL. Recent studies indicate that background concentrations of Hg in water from this unconfined sand and gravel aquifer system are < 10 ng/L. Additional sampling was conducted at the CSL site in order to better understand sources of Hg and potential Hg transport mechanisms in the areas with Hg-contaminated ground water. At the CSL site, concentrations of Hg were substantially lower (although still exceeding the MCL in some cases) in filtered water samples than in the unfiltered water samples collected previously from the same wells. Surfactants and elevated concentrations of sodium, chloride, nitrate, ammonium, and phosphate in water from domestic and observation wells indicated septic-system effects on water quality; detections of sulfide indicated localized reducing conditions. Hg concentrations in septage and leach-field effluent sampled at several other households in the region were low relative to the contaminant-level Hg concentrations in water from domestic wells. Relations of Hg concentrations in leach-field effluent to iron concentrations indicate that reductive dissolution of iron hydroxides in soils may release Hg to the percolating effluent. ?? 2005 Elsevier B.V. All rights reserved.

  11. Characterization of Libby, MT amphibole (LA) elongated particles for toxicology studies: Field Collection, sample preparation, dose characterization, and particle counting methods using SEM/EDS

    EPA Science Inventory

    Since 1999, the US EPA and USGS have been studying the chemistry, mineralogy, and morphology of the amphiboles from the Rainy Creek Complex of Libby, MT (LA), following an increased incidence of lung and pleural diseases. LA material collected in 2000 (LA2000) was described in M...

  12. Mapping of Sample Collection Data: GIS Tools for the Natural Product Researcher

    PubMed Central

    Oberlies, Nicholas H.; Rineer, James I.; Alali, Feras Q.; Tawaha, Khaled; Falkinham, Joseph O.; Wheaton, William D.

    2009-01-01

    Scientists engaged in the research of natural products often either conduct field collections themselves or collaborate with partners who do, such as botanists, mycologists, or SCUBA divers. The information gleaned from such collecting trips (e.g. longitude/latitude coordinates, geography, elevation, and a multitude of other field observations) have provided valuable data to the scientific community (e.g., biodiversity), even if it is tangential to the direct aims of the natural products research, which are often focused on drug discovery and/or chemical ecology. Geographic Information Systems (GIS) have been used to display, manage, and analyze geographic data, including collection sites for natural products. However, to the uninitiated, these tools are often beyond the financial and/or computational means of the natural product scientist. With new, free, and easy-to-use geospatial visualization tools, such as Google Earth, mapping and geographic imaging of sampling data are now within the reach of natural products scientists. The goals of the present study were to develop simple tools that are tailored for the natural products setting, thereby presenting a means to map such information, particularly via open source software like Google Earth. PMID:20161345

  13. Seasonal Patterns of Melatonin, Cortisol, and Progesterone Secretion in Female Lambs Raised Beneath a 500-KV Transmission Line

    NASA Astrophysics Data System (ADS)

    Lee, Jack Monroe, Jr.

    There is ongoing controversy about the possibility of adverse biological effects from environmental exposures to electric and magnetic fields. These fields are produced by all electrical equipment and appliances including electrical transmission lines. The objective of this environmental science study was to investigate the possible effects of a high voltage transmission line on domestic sheep (Ovis aries L.), a species that can often be found near such lines. The study was primarily designed to determine whether a specific effect of electric and magnetic fields found in laboratory animals also occurs in livestock under natural environmental conditions. The effect is the ability of fields, at levels found in the environment, to significantly depress the normally high nocturnal concentrations of the pineal hormone-melatonin. Ten female Suffolk lambs were penned for 10 months directly beneath a 500-kV transmission line near Estacada, Oregon. Ten other lambs of the same type were penned in a control area away from the transmission line where electric and magnetic fields were at ambient levels. Serum melatonin was analyzed by radioimmunoassay (RIA) from 6618 blood samples collected at 0.5 to 3-hour intervals over eight 48-hour periods. Serum progesterone was analyzed by RIA from blood samples collected twice weekly. Serum cortisol was also assayed by RIA from the blood samples collected during the 48-hour samples. Results showed that lambs in both the control and line groups had the typical pattern of melatonin secretion consisting of low daytime and high nighttime serum concentrations. There were no statistically significant differences between groups in melatonin levels, or in the phase or duration of the nighttime melatonin elevation. Age at puberty and number of reproductive cycles also did not differ between groups. Serum cortisol showed a circadian rhythm with highest concentrations during the day. There were, however, no differences in cortisol concentrations between groups. Statistical analyses on other biological parameters revealed no differences between groups for body weight gain, wool growth, or behavior.

  14. Successful application of FTA Classic Card technology and use of bacteriophage phi29 DNA polymerase for large-scale field sampling and cloning of complete maize streak virus genomes.

    PubMed

    Owor, Betty E; Shepherd, Dionne N; Taylor, Nigel J; Edema, Richard; Monjane, Adérito L; Thomson, Jennifer A; Martin, Darren P; Varsani, Arvind

    2007-03-01

    Leaf samples from 155 maize streak virus (MSV)-infected maize plants were collected from 155 farmers' fields in 23 districts in Uganda in May/June 2005 by leaf-pressing infected samples onto FTA Classic Cards. Viral DNA was successfully extracted from cards stored at room temperature for 9 months. The diversity of 127 MSV isolates was analysed by PCR-generated RFLPs. Six representative isolates having different RFLP patterns and causing either severe, moderate or mild disease symptoms, were chosen for amplification from FTA cards by bacteriophage phi29 DNA polymerase using the TempliPhi system. Full-length genomes were inserted into a cloning vector using a unique restriction enzyme site, and sequenced. The 1.3-kb PCR product amplified directly from FTA-eluted DNA and used for RFLP analysis was also cloned and sequenced. Comparison of cloned whole genome sequences with those of the original PCR products indicated that the correct virus genome had been cloned and that no errors were introduced by the phi29 polymerase. This is the first successful large-scale application of FTA card technology to the field, and illustrates the ease with which large numbers of infected samples can be collected and stored for downstream molecular applications such as diversity analysis and cloning of potentially new virus genomes.

  15. Field portable low temperature porous layer open tubular cryoadsorption headspace sampling and analysis part II: Applications.

    PubMed

    Harries, Megan; Bukovsky-Reyes, Santiago; Bruno, Thomas J

    2016-01-15

    This paper details the sampling methods used with the field portable porous layer open tubular cryoadsorption (PLOT-cryo) approach, described in Part I of this two-part series, applied to several analytes of interest. We conducted tests with coumarin and 2,4,6-trinitrotoluene (two solutes that were used in initial development of PLOT-cryo technology), naphthalene, aviation turbine kerosene, and diesel fuel, on a variety of matrices and test beds. We demonstrated that these analytes can be easily detected and reliably identified using the portable unit for analyte collection. By leveraging efficiency-boosting temperature control and the high flow rate multiple capillary wafer, very short collection times (as low as 3s) yielded accurate detection. For diesel fuel spiked on glass beads, we determined a method detection limit below 1 ppm. We observed greater variability among separate samples analyzed with the portable unit than previously documented in work using the laboratory-based PLOT-cryo technology. We identify three likely sources that may help explain the additional variation: the use of a compressed air source to generate suction, matrix geometry, and variability in the local vapor concentration around the sampling probe as solute depletion occurs both locally around the probe and in the test bed as a whole. This field-portable adaptation of the PLOT-cryo approach has numerous and diverse potential applications. Published by Elsevier B.V.

  16. Field Portable Low Temperature Porous Layer Open Tubular Cryoadsorption Headspace Sampling and Analysis Part II: Applications*

    PubMed Central

    Harries, Megan; Bukovsky-Reyes, Santiago; Bruno, Thomas J.

    2016-01-01

    This paper details the sampling methods used with the field portable porous layer open tubular cryoadsorption (PLOT-cryo) approach, described in Part I of this two-part series, applied to several analytes of interest. We conducted tests with coumarin and 2,4,6-trinitrotoluene (two solutes that were used in initial development of PLOT-cryo technology), naphthalene, aviation turbine kerosene, and diesel fuel, on a variety of matrices and test beds. We demonstrated that these analytes can be easily detected and reliably identified using the portable unit for analyte collection. By leveraging efficiency-boosting temperature control and the high flow rate multiple capillary wafer, very short collection times (as low as 3 s) yielded accurate detection. For diesel fuel spiked on glass beads, we determined a method detection limit below 1 ppm. We observed greater variability among separate samples analyzed with the portable unit than previously documented in work using the laboratory-based PLOT-cryo technology. We identify three likely sources that may help explain the additional variation: the use of a compressed air source to generate suction, matrix geometry, and variability in the local vapor concentration around the sampling probe as solute depletion occurs both locally around the probe and in the test bed as a whole. This field-portable adaptation of the PLOT-cryo approach has numerous and diverse potential applications. PMID:26726934

  17. Characterization of intracellular and extracellular saxitoxin levels in both field and cultured Alexandrium spp. samples from Sequim Bay, Washington.

    PubMed

    Lefebvre, Kathi A; Bill, Brian D; Erickson, Aleta; Baugh, Keri A; O'Rourke, Lohna; Costa, Pedro R; Nance, Shelly; Trainer, Vera L

    2008-05-14

    Traditionally, harmful algal bloom studies have primarily focused on quantifying toxin levels contained within the phytoplankton cells of interest. In the case of paralytic shellfish poisoning toxins (PSTs), intracellular toxin levels and the effects of dietary consumption of toxic cells by planktivores have been well documented. However, little information is available regarding the levels of extracellular PSTs that may leak or be released into seawater from toxic cells during blooms. In order to fully evaluate the risks of harmful algal bloom toxins in the marine food web, it is necessary to understand all potential routes of exposure. In the present study, extracellular and intracellular PST levels were measured in field seawater samples (collected weekly from June to October 2004-2007) and in Alexandrium spp. culture samples isolated from Sequim Bay, Washington. Measurable levels of intra- and extra-cellular toxins were detected in both field and culture samples via receptor binding assay (RBA) and an enzyme-linked immunosorbent assay (ELISA). Characterization of the PST toxin profile in the Sequim Bay isolates by pre-column oxidation and HPLC-fluorescence detection revealed that gonyautoxin 1 and 4 made up 65 +/- 9.7% of the total PSTs present. Collectively, these data confirm that extracellular PSTs are present during blooms of Alexandrium spp. in the Sequim Bay region.

  18. Characterization of Intracellular and Extracellular Saxitoxin Levels in Both Field and Cultured Alexandrium spp. Samples from Sequim Bay, Washington

    PubMed Central

    Lefebvre, Kathi A.; Bill, Brian D.; Erickson, Aleta; Baugh, Keri A.; O’Rourke, Lohna; Costa, Pedro R.; Nance, Shelly; Trainer, Vera L.

    2008-01-01

    Traditionally, harmful algal bloom studies have primarily focused on quantifying toxin levels contained within the phytoplankton cells of interest. In the case of paralytic shellfish poisoning toxins (PSTs), intracellular toxin levels and the effects of dietary consumption of toxic cells by planktivores have been well documented. However, little information is available regarding the levels of extracellular PSTs that may leak or be released into seawater from toxic cells during blooms. In order to fully evaluate the risks of harmful algal bloom toxins in the marine food web, it is necessary to understand all potential routes of exposure. In the present study, extracellular and intracellular PST levels were measured in field seawater samples (collected weekly from June to October 2004–2007) and in Alexandrium spp. culture samples isolated from Sequim Bay, Washington. Measurable levels of intra- and extra-cellular toxins were detected in both field and culture samples via receptor binding assay (RBA) and an enzyme-linked immunosorbent assay (ELISA). Characterization of the PST toxin profile in the Sequim Bay isolates by pre-column oxidation and HPLC-fluorescence detection revealed that gonyautoxin 1 and 4 made up 65 ± 9.7 % of the total PSTs present. Collectively, these data confirm that extracellular PSTs are present during blooms of Alexandrium spp. in the Sequim Bay region. PMID:18728762

  19. Optimizing detection of noble gas emission at a former UNE site: sample strategy, collection, and analysis

    NASA Astrophysics Data System (ADS)

    Kirkham, R.; Olsen, K.; Hayes, J. C.; Emer, D. F.

    2013-12-01

    Underground nuclear tests may be first detected by seismic or air samplers operated by the CTBTO (Comprehensive Nuclear-Test-Ban Treaty Organization). After initial detection of a suspicious event, member nations may call for an On-Site Inspection (OSI) that in part, will sample for localized releases of radioactive noble gases and particles. Although much of the commercially available equipment and methods used for surface and subsurface environmental sampling of gases can be used for an OSI scenario, on-site sampling conditions, required sampling volumes and establishment of background concentrations of noble gases require development of specialized methodologies. To facilitate development of sampling equipment and methodologies that address OSI sampling volume and detection objectives, and to collect information required for model development, a field test site was created at a former underground nuclear explosion site located in welded volcanic tuff. A mixture of SF-6, Xe127 and Ar37 was metered into 4400 m3 of air as it was injected into the top region of the UNE cavity. These tracers were expected to move towards the surface primarily in response to barometric pumping or through delayed cavity pressurization (accelerated transport to minimize source decay time). Sampling approaches compared during the field exercise included sampling at the soil surface, inside surface fractures, and at soil vapor extraction points at depths down to 2 m. Effectiveness of various sampling approaches and the results of tracer gas measurements will be presented.

  20. Surface- and Ground-Water Monitoring and Mapping of Selected Features at the Blue Ridge Parkway Mt. Pisgah Campground, Haywood County, North Carolina, 2002

    USGS Publications Warehouse

    Smith, Douglas G.

    2004-01-01

    During 2002, a baseline study of hydrologic conditions was conducted, and selected features were mapped within the Mt. Pisgah campground on the Blue Ridge Parkway in Haywood County, North Carolina. Field surveys were performed by using global positioning system equipment one time (January 2002) during the study to locate hydrologic and other types of features in the study area. Water-level and streamflow data and seasonal water-quality samples were collected from a stream that receives all surface-water drainage from the campground area. During 2002, water levels (stage) in the stream ranged from 1.09 to 1.89 feet above gage datum (4,838.06 to 4,838.86 feet above mean sea level). Flow in the stream ranged from 0.05 to 9.7 cubic feet per second. Annual daily mean flow for calendar year 2002 was approximately 0.35 cubic foot per second (about 226,000 gallons per day). Samples collected from the stream had low concentrations of all constituents measured. Four compounds associated with human activity (camphor, N,N-diethyl-meta-toluamide (the insect repellent DEET), tributylphosphate, and methylsalicylate) were detected in the stream samples; however, concentrations were less than detection levels. Stream samples collected in April and September and analyzed for fecal coliform bacteria had densities of 76 and 110 colonies per 100 milliliters of water, respectively. No violations of water-quality standards were noted for any constituent measured in the stream samples. Seven shallow ground-water wells were installed near a natural area in the center of the campground. Ground-water levels measured periodically in these wells and in two existing shallow piezometers generally were highest in the spring and lowest in the fall. Water temperature, pH, and specific conductance were measured in samples collected from the shallow wells in April and September 2002. Measured pH values were consistently lowest in samples from two wells on the west side of the natural area and highest in samples from the well located near the center of the natural area. Specific-conductance values measured in samples from wells on the east side of the natural area were lower than those measured in samples from the other wells. Specific-conductance values measured in samples from two wells on the west side and from one well near the center of the natural area generally were two to three times higher than the specific-conductance values measured in samples from wells on the east side of the natural area. Samples for fecal coliform bacteria were collected from six wells on September 11, 2002. The fecal coliform densities in samples from most of the wells were less than or equal to 8 colonies per 100 milliliters. Samples from two of the three wells on the west side of the natural area had coliform densities of 16 and 480 colonies per 100 milliliters. Other ground-water samples collected on September 11 and September 24 were analyzed with a spectrophotometer in the U.S. Geological Survey (USGS) North Carolina District Office for nitrate concentrations only. From the samples collected on September 11, estimated nitrate concentrations of 1 milligram per liter or less were detected in three wells, two on the west side and one on the east side of the natural area. Nitrate was not detected with a spectrophotometer in any of the ground-water samples collected on September 24. Indicator test strips also were used in the field to screen for nitrate and nitrite in ground-water samples collected on September 24. Nitrate was detected by test strips in one well on the west side of the natural area, with estimated concentrations of 1 milligram per liter or less indicated. Nitrite was not detected by the test strips in samples collected from any of the wells.

  1. Field measurements of biogenic volatile organic compounds in the atmosphere using solid-phase microextraction Arrow

    NASA Astrophysics Data System (ADS)

    Feijó Barreira, Luís Miguel; Duporté, Geoffroy; Rönkkö, Tuukka; Parshintsev, Jevgeni; Hartonen, Kari; Hyrsky, Lydia; Heikkinen, Enna; Jussila, Matti; Kulmala, Markku; Riekkola, Marja-Liisa

    2018-02-01

    Biogenic volatile organic compounds (BVOCs) emitted by terrestrial vegetation participate in a diversity of natural processes. These compounds impact both short-range processes, such as on plant protection and communication, and long-range processes, for example by participating in aerosol particle formation and growth. The biodiversity of plant species around the Earth, the vast assortment of emitted BVOCs, and their trace atmospheric concentrations contribute to the substantial remaining uncertainties about the effects of these compounds on atmospheric chemistry and physics, and call for the development of novel collection devices that can offer portability with improved selectivity and capacity. In this study, a novel solid-phase microextraction (SPME) Arrow sampling system was used for the static and dynamic collection of BVOCs from a boreal forest, and samples were subsequently analyzed on site by gas chromatography-mass spectrometry (GC-MS). This system offers higher sampling capacity and improved robustness when compared to traditional equilibrium-based SPME techniques, such as SPME fibers. Field measurements were performed in summer 2017 at the Station for Measuring Ecosystem-Atmosphere Relations (SMEAR II) in Hyytiälä, Finland. Complementary laboratory tests were also performed to compare the SPME-based techniques under controlled experimental conditions and to evaluate the effect of temperature and relative humidity on their extraction performance. The most abundant monoterpenes and aldehydes were successfully collected. A significant improvement on sampling capacity was observed with the new SPME Arrow system over SPME fibers, with collected amounts being approximately 2 × higher for monoterpenes and 7-8 × higher for aldehydes. BVOC species exhibited different affinities for the type of sorbent materials used (polydimethylsiloxane (PDMS)-carbon wide range (WR) vs. PDMS-divinylbenzene (DVB)). Higher extraction efficiencies were obtained with dynamic collection prior to equilibrium regime, but this benefit during the field measurements was small, probably due to the natural agitation provided by the wind. An increase in temperature and relative humidity caused a decrease in the amounts of analytes extracted under controlled experimental conditions, even though the effect was more significant for PDMS-carbon WR than for PDMS-DVB. Overall, results demonstrated the benefits and challenges of using SPME Arrow for the sampling of BVOCs in the atmosphere.

  2. Suspended particulate matter collection methods influence the quantification of polycyclic aromatic compounds in the river system.

    PubMed

    Abuhelou, Fayez; Mansuy-Huault, Laurence; Lorgeoux, Catherine; Catteloin, Delphine; Collin, Valéry; Bauer, Allan; Kanbar, Hussein Jaafar; Gley, Renaud; Manceau, Luc; Thomas, Fabien; Montargès-Pelletier, Emmanuelle

    2017-10-01

    In this study, we compared the influence of two different collection methods, filtration (FT) and continuous flow field centrifugation (CFC), on the concentration and the distribution of polycyclic aromatic compounds (PACs) in suspended particulate matter (SPM) occurring in river waters. SPM samples were collected simultaneously with FT and CFC from a river during six sampling campaigns over 2 years, covering different hydrological contexts. SPM samples were analyzed to determine the concentration of PACs including 16 polycyclic aromatic hydrocarbons (PAHs), 11 oxygenated PACs (O-PACs), and 5 nitrogen PACs (N-PACs). Results showed significant differences between the two separation methods. In half of the sampling campaigns, PAC concentrations differed from a factor 2 to 30 comparing FT and CFC-collected SPMs. The PAC distributions were also affected by the separation method. FT-collected SPM were enriched in 2-3 ring PACs whereas CFC-collected SPM had PAC distributions dominated by medium to high molecular weight compounds typical of combustion processes. This could be explained by distinct cut-off threshold of the two separation methods and strongly suggested the retention of colloidal and/or fine matter on glass-fiber filters particularly enriched in low molecular PACs. These differences between FT and CFC were not systematic but rather enhanced by high water flow rates.

  3. Snow crystal imaging using scanning electron microscopy: III. Glacier ice, snow and biota

    USGS Publications Warehouse

    Rango, A.; Wergin, W.P.; Erbe, E.F.; Josberger, E.G.

    2000-01-01

    Low-temperature scanning electron microscopy (SEM) was used to observe metamorphosed snow, glacial firn, and glacial ice obtained from South Cascade Glacier in Washington State, USA. Biotic samples consisting of algae (Chlamydomonas nivalis) and ice worms (a species of oligochaetes) were also collected and imaged. In the field, the snow and biological samples were mounted on copper plates, cooled in liquid nitrogen, and stored in dry shipping containers which maintain a temperature of -196??C. The firn and glacier ice samples were obtained by extracting horizontal ice cores, 8 mm in diameter, at different levels from larger standard glaciological (vertical) ice cores 7.5 cm in diameter. These samples were cooled in liquid nitrogen and placed in cryotubes, were stored in the same dry shipping container, and sent to the SEM facility. In the laboratory, the samples were sputter coated with platinum and imaged by a low-temperature SEM. To image the firn and glacier ice samples, the cores were fractured in liquid nitrogen, attached to a specimen holder, and then imaged. While light microscope images of snow and ice are difficult to interpret because of internal reflection and refraction, the SEM images provide a clear and unique view of the surface of the samples because they are generated from electrons emitted or reflected only from the surface of the sample. In addition, the SEM has a great depth of field with a wide range of magnifying capabilities. The resulting images clearly show the individual grains of the seasonal snowpack and the bonding between the snow grains. Images of firn show individual ice crystals, the bonding between the crystals, and connected air spaces. Images of glacier ice show a crystal structure on a scale of 1-2 mm which is considerably smaller than the expected crystal size. Microscopic air bubbles, less than 15 ??m in diameter, clearly marked the boundaries between these crystal-like features. The life forms associated with the glacier were easily imaged and studied. The low-temperature SEM sample collecting and handling methods proved to be operable in the field; the SEM analysis is applicable to glaciological studies and reveals details unattainable by conventional light microscopic methods.Low temperature scanning electron microscopy (SEM) was used to observe metamorphosed snow, glacial firn, and glacial ice obtained from South Cascade Glacier in Washington State, USA. Biotic samples consisting of algae and ice worms were also collected and imaged. The SEM images provide a clear and unique view of the surface of the samples because they are generated from electrons emitted or reflected only from the surface of the sample. The SEM has a great depth of field with a wide range of magnifying capabilities.

  4. Understanding Microplastic Distribution: A Global Citizen Monitoring Effort

    NASA Astrophysics Data System (ADS)

    Barrows, A.

    2016-02-01

    Understanding distribution and abundance of microplastics in the world's oceans will continue to help inform global law-making. Through recruiting and training over 500 volunteers our study has collected over 1000 samples from remote and populated areas world-wide. Samples include water collected at the sea surface and throughout the water column. Surface to depth sampling has provided insight into vertical plastic distribution. The development of unique field and laboratory methodology has enabled plastics to be quantified down to 50 µm. In 2015, the study expanded to include global freshwater systems. By understanding plastic patterns, distribution and concentration in large and small watersheds we will better understand how freshwater systems are contributing to marine microplastic pollution.

  5. Applications and use of transportation data

    DOT National Transportation Integrated Search

    1979-01-01

    This research paper is a compilation of seven documents which focus on the application and use of transportation data. The following papers are included: "Field data collection and sampling procedures for measuring regional vehicle classification and...

  6. Tank Vapor Sampling and Analysis Data Package for Tank 241-Z-361 Sampled 09/22/1999 and 09/271999 During Sludge Core Removal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    VISWANATH, R.S.

    This data package presents sampling data and analytical results from the September 22 and 27, 1999, headspace vapor sampling of Hanford Site Tank 241-2-361 during sludge core removal. The Lockheed Martin Hanford Corporation (LMHC) sampling team collected the samples and Waste Management Laboratory (WML) analyzed the samples in accordance with the requirements specified in the 241-2361 Sludge Characterization Sampling and Analysis Plan, (SAP), HNF-4371, Rev. 1, (Babcock and Wilcox Hanford Corporation, 1999). Six SUMMA{trademark} canister samples were collected on each day (1 ambient field blank and 5 tank vapor samples collected when each core segment was removed). The samples weremore » radiologically released on September 28 and October 4, 1999, and received at the laboratory on September 29 and October 6, 1999. Target analytes were not detected at concentrations greater than their notification limits as specified in the SAP. Analytical results for the target analytes and tentatively identified compounds (TICs) are presented in Section 2.2.2 starting on page 2B-7. Three compounds identified for analysis in the SAP were analyzed as TICs. The discussion of this modification is presented in Section 2.2.1.2.« less

  7. Updated study reporting levels (SRLs) for trace-element data collected for the California Groundwater Ambient Monitoring and Assessment (GAMA) Priority Basin Project, October 2009-March 2013

    USGS Publications Warehouse

    Davis, Tracy A.; Olsen, Lisa D.; Fram, Miranda S.; Belitz, Kenneth

    2014-01-01

    Groundwater samples have been collected in California as part of statewide investigations of groundwater quality conducted by the U.S. Geological Survey for the Groundwater Ambient Monitoring and Assessment (GAMA) Priority Basin Project (PBP). The GAMA-PBP is being conducted in cooperation with the California State Water Resources Control Board to assess and monitor the quality of groundwater resources used for drinking-water supply and to improve public knowledge of groundwater quality in California. Quality-control samples (source-solution blanks, equipment blanks, and field blanks) were collected in order to ensure the quality of the groundwater sample results. Olsen and others (2010) previously determined study reporting levels (SRLs) for trace-element results based primarily on field blanks collected in California from May 2004 through January 2008. SRLs are raised reporting levels used to reduce the likelihood of reporting false detections attributable to contamination bias. The purpose of this report is to identify any changes in the frequency and concentrations of detections in field blanks since the last evaluation and update the SRLs for more recent data accordingly. Constituents analyzed were aluminum (Al), antimony (Sb), arsenic (As), barium (Ba), beryllium (Be), boron (B), cadmium (Cd), chromium (Cr), cobalt (Co), copper (Cu), iron (Fe), lead (Pb), lithium (Li), manganese (Mn), molybdenum (Mo), nickel (Ni), selenium (Se), silver (Ag), strontium (Sr), thallium (Tl), tungsten (W), uranium (U), vanadium (V), and zinc (Zn). Data from 179 field blanks and equipment blanks collected from March 2006 through March 2013 by the GAMA-PBP indicated that for trace elements that had a change in detection frequency and concentration since the previous review, the shift occurred near October 2009, in conjunction with a change in the capsule filters used by the study. Results for 89 field blanks and equipment blanks collected from October 2009 through March 2013 were evaluated for potential contamination bias by using the same approach developed by Olsen and others (2010). Some data collected by the National Water-Quality Assessment (NAWQA) Program for the Southern California Coastal Drainages study unit were included to supplement the GAMA-PBP data. The detection frequency and upper threshold of potential contamination bias (BD-90/90) were determined from field-blank and equipment-blank data for each trace element. The BD-90/90 is the 90th percentile concentration of potential extrinsic contamination calculated by using the binomial probability distribution for greater than 90 percent confidence. Additionally, data from laboratory blanks and blind blanks analyzed by the National Water Quality Laboratory (NWQL) during water years 2010 through 2013, and compiled by the USGS Branch of Quality Systems (BQS), were considered for each trace element. These results were compared to each constituent’s reporting level to determine whether an SRL was necessary to minimize the potential for detections in the groundwater samples, attributed principally to contamination bias. Results of the evaluation were used to set SRLs for trace-element data for about 1,135 samples of groundwater collected by the GAMA-PBP between October 2009 and March 2013. Ten trace elements analyzed (Sb, As, Be, B, Cd, Li, Se, Ag, Tl, and U) had blank results that did not necessitate establishing SRLs during this review or the review by Olsen and others (2010). Five trace elements analyzed (Al, Ba, Cr, Sr, and V) had blank results that necessitated establishing an SRL during the previous review but did not need an SRL starting October 2009. One trace element (Fe) had field and laboratory-blank results that necessitated keeping the previous SRL (6 micrograms per liter [μg/L]). Two trace elements (Ni and W) had quality-control results that warranted decreasing the previous SRL, and five trace elements (Cu, Pb, Mn, Mo, and Zn) had field, laboratory, or blind blank results that warranted establishing an SRL for the first time or increasing the previous SRL. SRLs for Cu (2.1 μg/L), Pb (0.82 μg/L), Mn (0.66 μg/L), Mo (0.023 μg/L), Ni (0.21 μg/L), W (0.023 μg/L), and Zn (6.2 μg/L) were changed to these levels starting October 2009, based on the BD-90/90 concentration for field blanks or the 99th percentile concentration for laboratory or blind blanks. The SRL for Fe was maintained at 6 μg/L, based on the minimum laboratory reporting level for iron. SRLs for these eight constituents were at least an order of magnitude below the regulatory benchmarks established for drinking water for health and aesthetic purposes; therefore, the practice of reporting concentrations below the SRLs as less than or equal to (≤) the measured value would not prevent the identification of values greater than the drinking-water benchmarks. Co was detected in 99 percent of field blanks, and with a BD-90/90 concentration of 0.38 μg/L, all groundwater results starting October 2009 were coded as “reviewed and rejected.” Co does not currently have a regulatory benchmark for drinking water. The primary sources of contamination for trace elements inferred from this review are the equipment or processes used in the field to collect the samples or in the laboratory. In particular, contamination in field blanks of Co and Mn was attributed to the high-capacity 0.45-micrometer pore-size capsule filters that were in regular use beginning in October 2009 by several USGS programs, including the GAMA-PBP and NAWQA Program, for filtering samples for analysis of trace elements. The SRLs determined in this report are intended to be used for GAMA groundwater-quality data for samples collected October 2009 through March 2013, or for as long as quality-control data indicate contamination similar to what was observed in this report; quality-control data should be continuously reviewed and SRLs re-assessed on at least a study-unit basis.

  8. Data on dissolved pesticides and volatile organic compounds in surface and ground waters in the San Joaquin-Tulare basins, California, water years 1992-1995

    USGS Publications Warehouse

    Kinsey, Willie B.; Johnson, Mark V.; Gronberg, JoAnn M.

    2005-01-01

    This report contains pesticide, volatile organic compound, major ion, nutrient, tritium, stable isotope, organic carbon, and trace-metal data collected from 149 ground-water wells, and pesticide data collected from 39 surface-water stream sites in the San Joaquin Valley of California. Included with the ground-water data are field measurements of pH, specific conductance, alkalinity, temperature, and dissolved oxygen. This report describes data collection procedures, analytical methods, quality assurance, and quality controls used by the National Water-Quality Assessment Program to ensure data reliability. Data contained in this report were collected during a four year period by the San Joaquin?Tulare Basins Study Unit of the United States Geological Survey's National Water-Quality Assessment Program. Surface-water-quality data collection began in April 1992, with sampling done three times a week at three sites as part of a pilot study conducted to provide background information for the surface-water-study design. Monthly samples were collected at 10 sites for major ions and nutrients from January 1993 to March 1995. Additional samples were collected at four of these sites, from January to December 1993, to study spatial and temporal variability in dissolved pesticide concentrations. Samples for several synoptic studies were collected from 1993 to 1995. Ground-water-quality data collection was restricted to the eastern alluvial fans subarea of the San Joaquin Valley. Data collection began in 1993 with the sampling of 21 wells in vineyard land-use settings. In 1994, 29 wells were sampled in almond land-use settings and 9 in vineyard land-use settings; an additional 11 wells were sampled along a flow path in the eastern Fresno County vineyard land-use area. Among the 79 wells sampled in 1995, 30 wells were in the corn, alfalfa, and vegetable land-use setting, and 1 well was in the vineyard land-use setting; an additional 20 were flow-path wells. Also sampled in 1995 were 28 wells used for a regional assessment of ground-water quality in the eastern San Joaquin Valley.

  9. Residential Transportation Energy Consumption Survey (RTECS)

    EIA Publications

    2005-01-01

    For roughly a decade, EIA fielded the RTECS--data were first collected in 1983. This survey, fielded for the last time in 1994, was a triennial survey of energy use and expenditures, vehicle miles-traveled (VMT), and vehicle characteristics for household vehicles. For the 1994 survey, a national sample of more than 3,000 households that own or use some 5,500 vehicles provided data.

  10. Amplicon-Based Sequencing of Soil Fungi from Wood Preservative Test Sites

    Treesearch

    Grant T. Kirker; Amy B. Bishell; Michelle A. Jusino; Jonathan M. Palmer; William J. Hickey; Daniel L. Lindner

    2017-01-01

    Soil samples were collected from field sites in two AWPA (American Wood Protection Association) wood decay hazard zones in North America. Two field plots at each site were exposed to differing preservative chemistries via in-ground installations of treated wood stakes for approximately 50 years. The purpose of this study is to characterize soil fungal species and to...

  11. Metazen – metadata capture for metagenomes

    DOE PAGES

    Bischof, Jared; Harrison, Travis; Paczian, Tobias; ...

    2014-12-08

    Background: As the impact and prevalence of large-scale metagenomic surveys grow, so does the acute need for more complete and standards compliant metadata. Metadata (data describing data) provides an essential complement to experimental data, helping to answer questions about its source, mode of collection, and reliability. Metadata collection and interpretation have become vital to the genomics and metagenomics communities, but considerable challenges remain, including exchange, curation, and distribution. Currently, tools are available for capturing basic field metadata during sampling, and for storing, updating and viewing it. These tools are not specifically designed for metagenomic surveys; in particular, they lack themore » appropriate metadata collection templates, a centralized storage repository, and a unique ID linking system that can be used to easily port complete and compatible metagenomic metadata into widely used assembly and sequence analysis tools. Results: Metazen was developed as a comprehensive framework designed to enable metadata capture for metagenomic sequencing projects. Specifically, Metazen provides a rapid, easy-to-use portal to encourage early deposition of project and sample metadata. Conclusion: Metazen is an interactive tool that aids users in recording their metadata in a complete and valid format. A defined set of mandatory fields captures vital information, while the option to add fields provides flexibility.« less

  12. Metazen – metadata capture for metagenomes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bischof, Jared; Harrison, Travis; Paczian, Tobias

    Background: As the impact and prevalence of large-scale metagenomic surveys grow, so does the acute need for more complete and standards compliant metadata. Metadata (data describing data) provides an essential complement to experimental data, helping to answer questions about its source, mode of collection, and reliability. Metadata collection and interpretation have become vital to the genomics and metagenomics communities, but considerable challenges remain, including exchange, curation, and distribution. Currently, tools are available for capturing basic field metadata during sampling, and for storing, updating and viewing it. These tools are not specifically designed for metagenomic surveys; in particular, they lack themore » appropriate metadata collection templates, a centralized storage repository, and a unique ID linking system that can be used to easily port complete and compatible metagenomic metadata into widely used assembly and sequence analysis tools. Results: Metazen was developed as a comprehensive framework designed to enable metadata capture for metagenomic sequencing projects. Specifically, Metazen provides a rapid, easy-to-use portal to encourage early deposition of project and sample metadata. Conclusion: Metazen is an interactive tool that aids users in recording their metadata in a complete and valid format. A defined set of mandatory fields captures vital information, while the option to add fields provides flexibility.« less

  13. Stroboscobic near-field scanning optical microscopy for 3D mapping of mode profiles of plasmonic nanostructures (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Dana, Aykutlu; Ozgur, Erol; Torunoglu, Gamze

    2016-09-01

    We present a dynamic approach to scanning near field optical microscopy that extends the measurement technique to the third dimension, by strobing the illumination in sync with the cantilever oscillation. Nitrogen vacancy (NV) centers in nanodiamonds placed on cantilever tips are used as stable emitters for emission enhancement. Local field enhancement and modulation of optical density states are mapped in three dimensions based on fluorescence intensity and spectrum changes as the tip is scanned over plasmonic nanostructures. The excitation of NV centers is done using a total internal reflection setup. Using a digital phase locked loop to pulse the excitation in various tip sample separations, 2D slices of fluorescence enhancement can be recorded. Alternatively, a conventional SNOM tip can be used to selectively couple wideband excitation to the collection path, with subdiffraction resolution of 60 nm in x and y and 10 nm in z directions. The approach solves the problem of tip-sample separation stabilization over extended periods of measurement time, required to collect data resolved in emission wavelength and three spatial dimensions. The method can provide a unique way of accessing the three dimensional field and mode profiles of nanophotonics structures.

  14. Blood meal analysis of tabanid fly after it biting the rare Sumatran rhinoceros.

    PubMed

    Rovie-Ryan, Jeffrine Japning; Zainuddin, Zainal Zahari; Marni, Wahap; Ahmad, Abdul Hamid; Ambu, Laurentius N; Payne, Junaidi

    2013-02-01

    To demonstrate a noninvasive large mammalian genetic sampling method using blood meal obtained from a tabanid fly. Blood meal was recovered from the abdomen of an engorged tabanid fly (Haematopota sp.) which was captured immediately after biting a Sumatran rhino in captivity. The blood was applied on to a Whatman FTA(®) blood card. Subsequent laboratory work was conducted to extract, amplify and sequence the DNA from the sample. Validation was done by sampling the hair follicles and blood samples from the rhinoceros and subjecting it to the same laboratory process. BLAST search and constructed phylogenetic trees confirmed the blood meal samples were indeed from the rhino. This method could be used in the field application to noninvasively collect genetic samples. Collection of tabanids and other haematophagous arthropods (e.g. mosquitoes and ticks) and other blood-sucking parasites (e.g. leeches and worms) could also provide information on vector-borne diseases.

  15. Prevalence of agglutinating antibodies to Toxoplasma gondii and Sarcocystis neurona in beavers (Castor canadensis) from Massachusetts

    USGS Publications Warehouse

    Jordan, C.N.; Kaur, T.; Koenen, K.; DeStefano, S.; Zajac, A.M.; Lindsay, D.S.

    2005-01-01

    The present study examined the seroprevalence of Toxoplasma gondii and Sarcocystls neurona in a population of beavers (Castor canadensis) from Massachusetts. Sixty-two blood samples were collected during the field seasons over 3 consecutive years from different animals. Blood was collected onto filter paper and shipped to the Department of Biomedical Sciences, Virginia Tech, Blacksburg, Virginia, for parasite testing. The samples were tested at dilutions of 1:25, 1:50, and 1:100 against each parasite antigen by modified agglutination tests to determine whether antibodies to either parasite were present in the blood. Six of 62 samples (10%) were positive for T. gondii, with 2 samples having titers of 1:25 and 4 having titers of 1:50. Four of 62 samples (6%) were positive for S. neurona, with 2 samples having titers of 1:25 and 2 having titers of 1:50. ?? American Society of Pathologists 2005.

  16. Evaluation of diagnostic assays for the serological detection of Actinobacillus pleuropneumoniae on samples of known or unknown exposure.

    PubMed

    Opriessnig, Tanja; Hemann, Michelle; Johnson, John K; Heinen, Sheila; Giménez-Lirola, Luis G; O'Neill, Kevin C; Hoang, Hai; Yoon, Kyoung-Jin; Gottschalk, Marcelo; Halbur, Patrick G

    2013-01-01

    Accurate diagnosis of exposure to Actinobacillus pleuropneumoniae is important for maintaining negative farms. In the present study, the ability of a dual-plate complement fixation (CF) assay and 3 commercially available enzyme-linked immunosorbent assays (ELISAs; quad-plate ELISA-1, single-plate ELISA-2, and single-plate ELISA-3) in detecting serological evidence of A. pleuropneumoniae exposure was compared using serum samples of experimentally infected or vaccinated pigs, or field samples from the United States. Forty-two pigs were divided into groups of 2 pigs and were inoculated with 1 of 15 A. pleuropneumoniae strains representing all known serovars of A. pleuropneumoniae, or with Actinobacillus suis, or were vaccinated with a bacterin containing A. pleuropneumoniae serovar 1, 3, 5, or 7. Serum samples collected at the day of inoculation or vaccination and 7, 14, 21, and 28 days later were used to compare the assays. On samples from experimentally infected pigs, the dual-plate CF assay, quad-plate ELISA-1, single-plate ELISA-2, and single-plate ELISA-3 had sensitivities of 0.46, 0.74, 0.13, and 0.13 and specificities of 0.90, 1.0, 1.0, and 1.0, respectively. Vaccinated pigs were identified only by the dual-plate CF assay and the quad-plate ELISA-1. In addition, 90 serum samples with unknown A. pleuropneumoniae exposure collected under field conditions were tested with all assays. The agreement of the 4 assays on field samples was slight to fair. While several assays are available for demonstration of A. pleuropneumoniae exposure, differences in assay targets complicate test choices. Decisions on which assay or combination of assays to use depend on the specific reasons for running the assays.

  17. Development of an automated high temperature valveless injection system for on-line gas chromatography

    NASA Astrophysics Data System (ADS)

    Kreisberg, N. M.; Worton, D. R.; Zhao, Y.; Isaacman, G.; Goldstein, A. H.; Hering, S. V.

    2014-07-01

    A reliable method of sample introduction is presented for on-line gas chromatography with a special application to in-situ field portable atmospheric sampling instruments. A traditional multi-port valve is replaced with a controlled pressure switching device that offers the advantage of long term reliability and stable sample transfer efficiency. An engineering design model is presented and tested that allows customizing the interface for other applications. Flow model accuracy is within measurement accuracy (1%) when parameters are tuned for an ambient detector and 15% accurate when applied to a vacuum based detector. Laboratory comparisons made between the two methods of sample introduction using a thermal desorption aerosol gas chromatograph (TAG) show approximately three times greater reproducibility maintained over the equivalent of a week of continuous sampling. Field performance results for two versions of the valveless interface used in the in-situ instrument demonstrate minimal trending and a zero failure rate during field deployments ranging up to four weeks of continuous sampling. Extension of the VLI to dual collection cells is presented with less than 3% cell-to-cell carry-over.

  18. Ground- and Surface-Water Chemistry of Handcart Gulch, Park County, Colorado, 2003-2006

    USGS Publications Warehouse

    Verplanck, Philip L.; Manning, Andrew H.; Kimball, Briant A.; McCleskey, R. Blaine; Runkel, Robert L.; Caine, Jonathan S.; Adams, Monique; Gemery-Hill, Pamela A.; Fey, David L.

    2008-01-01

    As part of a multidisciplinary project to determine the processes that control ground-water chemistry and flow in mineralized alpine environments, ground- and surface-water samples from Handcart Gulch, Colorado were collected for analysis of inorganic solutes and water and dissolved sulfate stable isotopes in selected samples. The primary aim of this study was to document variations in ground-water chemistry in Handcart Gulch and to identify changes in water chemistry along the receiving stream of Handcart Gulch. Water analyses are reported for ground-water samples collected from 12 wells in Handcart Gulch, Colorado. Samples were collected between August 2003 and October 2005. Water analyses for surface-water samples are reported for 50 samples collected from Handcart Gulch and its inflows during a low-flow tracer injection on August 6, 2003. In addition, water analyses are reported for three other Handcart Gulch stream samples collected in September 2005 and March 2006. Reported analyses include field parameters (pH, specific conductance, temperature, dissolved oxygen, and Eh), major and trace constituents, oxygen and hydrogen isotopic composition of water and oxygen and sulfur isotopic composition of dissolved sulfate. Ground-water samples from this study are Ca-SO4 type and range in pH from 2.5 to 6.8. Most of the samples (75 percent) have pH values between 3.3 and 4.3. Surface water samples are also Ca-SO4 type and have a narrower range in pH (2.7?4.0). Ground- and surface-water samples vary from relatively dilute (specific conductance of 68 ?S/cm) to concentrated (specific conductance of 2,000 ?S/cm).

  19. [Effect of sampling effort on taxa richness of aquatic macroinvertebrates and the BMWP/Atitlán index].

    PubMed

    Reyes-Morales, Fátima; Springer, Monika

    2014-04-01

    Aquatic macroinvertebrates are the group of organisms most commonly used to determine ecosystem health in water quality studies and freshwater biomonitoring. Nevertheless, the methods and collecting time of biomonitoring have not yet been sufficiently adapted and tested in tropical aquatic environments. Twelve rivers in the Lago de Atitlán watershed in Guatemala were assessed with different collecting times, during the dry season. The method involved the collection of organic and inorganic material including benthic organisms, from different microhabitats, for a pre-established time period (5, 10, 15 min) with a D-frame net. Samples were preserved with 95% ethanol in the field, and sorted in the laboratory. As expected, the analysis showed that the abundance and taxonomic richness was higher with increasing sampling effort. The water quality categories obtained from the newly proposed BMWP/Atitlán index varied among sampling times. However, the Kruskal-Wallis test showed no significant differences between the categories obtained with the index and the number of taxa collected at 10 and 15 min. Therefore, we recommend a reduction of sample time, but maintaining the tree subsamples in order to include most variety of microhabitats and assure a representative sample of the aquatic macroinvertebrates.

  20. Ground-water-quality and ground-water-level data, Bernalillo County, central New Mexico, 1990-1993

    USGS Publications Warehouse

    Kues, G.E.; Garcia, B.M.

    1995-01-01

    Ground-water-quality and ground-water-level data were collected in four unincorporated areas of Bernalillo County during 1990-93. Twenty wells in the east mountain area of Bernalillo County were sampled approximately monthly between January 1990 and June 1993. The water samples were analyzed for concentrations of chloride and selected nutrient species; many of the samples also were analyzed for concentrations of total organic carbon and dissolved boron and iron. Eleven wells northeast of the city of Albuquerque, 20 wells in the Rio Grande Valley immediately north of Albuquerque, and 30 wells in the Rio Grande Valley immediately south of Albuquerque were sampled once each between December 1992 and September 1993; all water samples were analyzed for chloride and selected nutrient species, and selected samples from wells in the north and south valley areas were also analyzed for major dissolved constituents, iron, manganese, and methylene blue active substances. Samples from 10 of the wells in the north and south valley areas were analyzed for 47 selected pesticides. Field measurements of specific conductance, pH, temperature, and alkalinity were made on most samples at the time of sample collection. Water levels also were measured at the time of sample collection when possible. Results of the monthly water-quality and water-level monitoring in the east mountain area of Bernalillo County are presented in graphical form. Water-quality and water-level data collected from the other areas are presented in tabular form.

  1. Using improved technology for filter paper-based blood collection to survey wild Sika deer for antibodies to hepatitis E virus.

    PubMed

    Yu, Claro; Zimmerman, Carl; Stone, Roger; Engle, Ronald E; Elkins, William; Nardone, Glenn A; Emerson, Suzanne U; Purcell, Robert H

    2007-06-01

    Recent reports from Japan implicated wild Sika deer (Cervus nippon) in the zoonotic transmission of hepatitis E to humans. Seroprevalence studies were performed to determine if imported feral populations of Sika deer in Maryland and Virginia posed a similar risk of transmitting hepatitis E virus (HEV). Hunters collected blood on filter paper discs from freshly killed deer. The discs were desiccated and delivered to a collection point. The dried filters were weighed to estimate the amount of blood absorbed and were eluted and collected in one tube via a novel extraction system. The procedure was quantified and validated with negative and positive serum and blood samples obtained from domestic Sika deer before and after immunization with HEV recombinant capsid protein, respectively. None of the 155 tested samples contained antibody to HEV, suggesting that Sika deer in these populations, unlike those in Japan, do not pose a significant zoonotic threat for hepatitis E. However, the new method developed for collecting and eluting the samples should prove useful for field studies of many other pathogens.

  2. Using improved technology for filter paper-based blood collection to survey wild Sika deer for antibodies to hepatitis E virus

    PubMed Central

    Zimmerman, Carl; Stone, Roger; Engle, Ronald E.; Elkins, William; Nardone, Glenn A.; Emerson, Suzanne U.; Purcell, Robert H.

    2009-01-01

    Recent reports from Japan implicated wild Sika deer (Cervus nippon) in the zoonotic transmission of hepatitis E to humans. Seroprevalence studies were performed to determine if imported feral populations of Sika deer in Maryland and Virginia posed a similar risk of transmitting hepatitis E virus (HEV). Hunters collected blood on filter paper disks from freshly killed deer. The disks were desiccated and delivered to a collection point. The dried filters were weighed to estimate the amount of blood absorbed and were eluted and collected in one tube via a novel extraction system. The procedure was quantified and validated with negative and positive serum and blood samples obtained from domestic Sika deer before and after immunization with HEV recombinant capsid protein, respectively. None of the 155 tested samples contained antibody to HEV, suggesting that Sika deer in these populations, unlike those in Japan, do not pose a significant zoonotic threat for hepatitis E. However, the new method developed for collecting and eluting the samples should prove useful for field studies of many other pathogens. PMID:17336401

  3. Sample Return Robot Centennial Challenge

    NASA Image and Video Library

    2012-06-16

    NASA Deputy Administrator Lori Garver, left, listens as Worcester Polytechnic Institute (WPI) Robotics Resource Center Director and NASA-WPI Sample Return Robot Centennial Challenge Judge Ken Stafford points out how the robots navigate the playing field during the challenge on Saturday, June 16, 2012 in Worcester, Mass. Teams were challenged to build autonomous robots that can identify, collect and return samples. NASA needs autonomous robotic capability for future planetary exploration. Photo Credit: (NASA/Bill Ingalls)

  4. Sample Return Robot Centennial Challenge

    NASA Image and Video Library

    2012-06-16

    NASA Deputy Administrator Lori Garver, right, listens as Worcester Polytechnic Institute (WPI) Robotics Resource Center Director and NASA-WPI Sample Return Robot Centennial Challenge Judge Ken Stafford points out how the robots navigate the playing field during the challenge on Saturday, June 16, 2012 in Worcester, Mass. Teams were challenged to build autonomous robots that can identify, collect and return samples. NASA needs autonomous robotic capability for future planetary exploration. Photo Credit: (NASA/Bill Ingalls)

  5. Sampling design and procedures for fixed surface-water sites in the Georgia-Florida coastal plain study unit, 1993

    USGS Publications Warehouse

    Hatzell, H.H.; Oaksford, E.T.; Asbury, C.E.

    1995-01-01

    The implementation of design guidelines for the National Water-Quality Assessment (NAWQA) Program has resulted in the development of new sampling procedures and the modification of existing procedures commonly used in the Water Resources Division of the U.S. Geological Survey. The Georgia-Florida Coastal Plain (GAFL) study unit began the intensive data collection phase of the program in October 1992. This report documents the implementation of the NAWQA guidelines by describing the sampling design and procedures for collecting surface-water samples in the GAFL study unit in 1993. This documentation is provided for agencies that use water-quality data and for future study units that will be entering the intensive phase of data collection. The sampling design is intended to account for large- and small-scale spatial variations, and temporal variations in water quality for the study area. Nine fixed sites were selected in drainage basins of different sizes and different land-use characteristics located in different land-resource provinces. Each of the nine fixed sites was sampled regularly for a combination of six constituent groups composed of physical and chemical constituents: field measurements, major ions and metals, nutrients, organic carbon, pesticides, and suspended sediments. Some sites were also sampled during high-flow conditions and storm events. Discussion of the sampling procedure is divided into three phases: sample collection, sample splitting, and sample processing. A cone splitter was used to split water samples for the analysis of the sampling constituent groups except organic carbon from approximately nine liters of stream water collected at four fixed sites that were sampled intensively. An example of the sample splitting schemes designed to provide the sample volumes required for each sample constituent group is described in detail. Information about onsite sample processing has been organized into a flowchart that describes a pathway for each of the constituent groups.

  6. Analysis of sequences from field samples reveals the presence of the recently described pepper vein yellows virus (genus Polerovirus) in six additional countries.

    PubMed

    Knierim, Dennis; Tsai, Wen-Shi; Kenyon, Lawrence

    2013-06-01

    Polerovirus infection was detected by reverse transcription polymerase chain reaction (RT-PCR) in 29 pepper plants (Capsicum spp.) and one black nightshade plant (Solanum nigrum) sample collected from fields in India, Indonesia, Mali, Philippines, Thailand and Taiwan. At least two representative samples for each country were selected to generate a general polerovirus RT-PCR product of 1.4 kb length for sequencing. Sequence analysis of the partial genome sequences revealed the presence of pepper vein yellows virus (PeVYV) in all 13 samples. A 1990 Australian herbarium sample of pepper described by serological means as infected with capsicum yellows virus (CYV) was identified by sequence analysis of a partial CP sequence as probably infected with a potato leaf roll virus (PLRV) isolate.

  7. Application of solid-phase microextraction for in vivo laboratory and field sampling of pharmaceuticals in fish.

    PubMed

    Zhou, Simon Ningsun; Oakes, Ken D; Servos, Mark R; Pawliszyn, Janusz

    2008-08-15

    Previous field studies utilizing solid-phase microextraction (SPME) predominantly focused on volatile and semivolatile compounds in air or water. Earlier in vivo sampling studies utilizing SPME were limited to the liquid matrix (blood). The present study has expanded the SPME technique to semisolid tissues under laboratory and field conditions through the investigation of both theoretical and applied experimental approaches. Pre-equilibrium extraction and desorption were performed in vivo in two separate animals. Excellent linearity was found between the amounts extracted by SPME from the muscle of living fish and the waterborne concentrations of pharmaceuticals. A simple SPME method is also described to simultaneously determine free and total analyte concentrations in living tissue. The utility of in vivo SPME sampling was evaluated in wild fish collected from a number of different river locations under varying degrees of influence from municipal wastewater effluents. Diphenhydramine and diltiazem were detected in the muscle of fish downstream of a local wastewater treatment plant. Based on this study, SPME demonstrated several important advantages such as simplicity, sensitivity, and robustness under laboratory and in vivo field sampling conditions.

  8. Topological properties of microwave magnetoelectric fields.

    PubMed

    Berezin, M; Kamenetskii, E O; Shavit, R

    2014-02-01

    Collective excitations of electron spins in a ferromagnetic sample dominated by the magnetic dipole-dipole interaction strongly influence the field structure of microwave radiation. A small quasi-two-dimensional ferrite disk with magnetic-dipolar-mode (MDM) oscillation spectra can behave as a source of specific fields in vacuum, termed magnetoelectric (ME) fields. A coupling between the time-varying electric and magnetic fields in the ME-field structures is different from such a coupling in regular electromagnetic fields. The ME fields are characterized by strong energy confinement at a subwavelength region of microwave radiation, topologically distinctive power-flow vortices, and helicity parameters [E. O. Kamenetskii, R. Joffe, and R. Shavit, Phys. Rev. E 87, 023201 (2013)]. We study topological properties of microwave ME fields by loading a MDM ferrite particle with different dielectric samples. We establish a close connection between the permittivity parameters of dielectric environment and the topology of ME fields. We show that the topology of ME fields is strongly correlated with the Fano-resonance spectra observed at terminals of a microwave structure. We reveal specific thresholds in the Fano-resonance spectra appearing at certain permittivity parameters of dielectric samples. We show that ME fields originated from MDM ferrite disks can be distinguished by topological portraits of the helicity parameters and can have a torsion degree of freedom. Importantly, the ME-field phenomena can be viewed as implementations of space-time coordinate transformations on waves.

  9. BOREAS TGB-5 Dissolved Organic Carbon Data from NSA Beaver Ponds

    NASA Technical Reports Server (NTRS)

    Bourbonniere, Rick; Hall, Forrest G. (Editor); Conrad, Sara K. (Editor)

    2000-01-01

    The BOReal Ecosystem-Atmosphere Study Trace Gas Biogeochemistry (BOREAS TGB-5) team collected several data sets related to carbon and trace gas fluxes and concentrations in the Northern Study Area (NSA). This data set contains concentrations of dissolved organic and inorganic carbon species from water samples collected at various NSA sites. In particular, this set covers the NSA Tower Beaver Pond Site and the NSA Gillam Road Beaver Pond Site, including data from all visits to open water sampling locations during the BOREAS field campaigns from April to September 1994. The data are provided in tabular ASCII files.

  10. COMPACT CASCADE IMPACTS

    DOEpatents

    Lippmann, M.

    1964-04-01

    A cascade particle impactor capable of collecting particles and distributing them according to size is described. In addition the device is capable of collecting on a pair of slides a series of different samples so that less time is required for the changing of slides. Other features of the device are its compactness and its ruggedness making it useful under field conditions. Essentially the unit consists of a main body with a series of transverse jets discharging on a pair of parallel, spaced glass plates. The plates are capable of being moved incremental in steps to obtain the multiple samples. (AEC)

  11. Degradation of atrazine and isoproturon in surface and sub-surface soil materials undergoing different moisture and aeration conditions.

    PubMed

    Issa, Salah; Wood, Martin

    2005-02-01

    The influence of different moisture and aeration conditions on the degradation of atrazine and isoproturon was investigated in environmental samples aseptically collected from surface and sub-surface zones of agricultural land. The materials were maintained at two moisture contents corresponding to just above field capacity or 90% of field capacity. Another two groups of samples were adjusted with water to above field capacity, and, at zero time, exposed to drying-rewetting cycles. Atrazine was more persistent (t(1/2) = 22-35 days) than isoproturon (t(1/2) = 5-17 days) in samples maintained at constant moisture conditions. The rate of degradation for both herbicides was higher in samples maintained at a moisture content of 90% of field capacity than in samples with higher moisture contents. The reduction in moisture content in samples undergoing desiccation from above field capacity to much lower than field capacity enhanced the degradation of isoproturon (t(1/2) = 9-12 days) but reduced the rate of atrazine degradation (t(1/2) = 23-35 days). This demonstrates the variability between different micro-organisms in their susceptibility to desiccation. Under anaerobic conditions generated in anaerobic jars, atrazine degraded much more rapidly than isoproturon in materials taken from three soil profiles (0-250 cm depth). It is suggested that some specific micro-organisms are able to survive and degrade herbicide under severe conditions of desiccation. Copyright (c) 2005 Society of Chemical Industry.

  12. Maps showing mines, quarries, and prospects, with analyses of samples, Gee Creek Wilderness, Polk and Monroe counties, Tennessee

    USGS Publications Warehouse

    Gazdik, Gertrude C.; Behum, Paul T.

    1983-01-01

    During the recent U.S. Bureau of Mines field investigation, 21 samples were collected (fig. 2) and were submitted to the Bureau's Reno Metallurgy Research Center, Reno, Nev., for analysis. All samples were tested for 40 elements by semiquantitative spectrographic analyses. Additional testing by atomic absorption, neutron activation, and wet chemical techniques was performed for selected elements on some samples. Two shale samples were submitted to the Bureau of Mines, Tuscaloosa Metallurgy Research Center, Tuscaloosa, Ala., for the evaluation of ceramic properties. 

  13. Scranton 1/sup 0/ x 2/sup 0/ NTMS area: New Jersey, New York, and Pennsylvania. Preliminary basic data report. National Uranium Resource Evaluation Program. Hydrogeochemical and stream sediment reconnaissance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ferguson, R.B.; Tones, P.L.

    1978-11-01

    Stream sediment and stream water samples were collected from small streams at 980 sites for a nominal density of one site per 18 square kilometers in rural areas. Ground water samples were collected at 1251 sites for a nominal density of one site per 13 square kilometers. Neutron activation analysis results are given for uranium and 16 other elements in sediments, and for uranium and 9 other elements in ground water and surface water. Field measurements and observations are reported for each site. Analytical data and field measurements are presented in tables and maps. Statistical summaries of data and amore » brief description of results are given. A generalized geologic map and a summary of the geology of the area are included.« less

  14. Collective strong coupling with homogeneous Rabi frequencies using a 3D lumped element microwave resonator

    NASA Astrophysics Data System (ADS)

    Angerer, Andreas; Astner, Thomas; Wirtitsch, Daniel; Sumiya, Hitoshi; Onoda, Shinobu; Isoya, Junichi; Putz, Stefan; Majer, Johannes

    2016-07-01

    We design and implement 3D-lumped element microwave cavities that spatially focus magnetic fields to a small mode volume. They allow coherent and uniform coupling to electron spins hosted by nitrogen vacancy centers in diamond. We achieve large homogeneous single spin coupling rates, with an enhancement of more than one order of magnitude compared to standard 3D cavities with a fundamental resonance at 3 GHz. Finite element simulations confirm that the magnetic field distribution is homogeneous throughout the entire sample volume, with a root mean square deviation of 1.54%. With a sample containing 1017 nitrogen vacancy electron spins, we achieve a collective coupling strength of Ω = 12 MHz, a cooperativity factor C = 27, and clearly enter the strong coupling regime. This allows to interface a macroscopic spin ensemble with microwave circuits, and the homogeneous Rabi frequency paves the way to manipulate the full ensemble population in a coherent way.

  15. Lessons Learned for Geologic Data Collection and Sampling: Insights from the Desert RATS 2010 Geologist Crewmembers

    NASA Technical Reports Server (NTRS)

    Hurtado, J. M., Jr.; Bleacher, J. E.; Rice, J.; Young, K.; Garry, W. B.; Eppler, D.

    2011-01-01

    Since 1997, Desert Research and Technology Studies (D-RATS) has conducted hardware and operations tests in the Arizona desert that advance human and robotic planetary exploration capabilities. D-RATS 2010 (8/31-9/13) simulated geologic traverses through a terrain of cinder cones, lava flows, and underlying sedimentary units using a pair of crewed rovers and extravehicular activities (EVAs) for geologic fieldwork. There were two sets of crews, each consisting of an engineer/commander and an experienced field geologist drawn from the academic community. A major objective of D-RATS was to examine the functions of a science support team, the roles of geologist crewmembers, and protocols, tools, and technologies needed for effective data collection and sample documentation. Solutions to these problems must consider how terrestrial field geology must be adapted to geologic fieldwork during EVAs

  16. Hair: a complementary source of bioanalytical information in forensic toxicology.

    PubMed

    Barroso, Mário; Gallardo, Eugenia; Vieira, Duarte Nuno; López-Rivadulla, Manuel; Queiroz, João António

    2011-01-01

    Hair has been used for years in the assessment and documentation of human exposure to drugs, as it presents characteristics that make it extremely valuable for this purpose, namely the fact that sample collection is performed in a noninvasive manner, under close supervision, the possibility of collecting a specimen reflecting a similar timeline in the case of claims or suspicion of a leak in the chain of custody, and the increased window of detection for the drugs. For these reasons, testing for drugs in hair provides unique and useful information in several fields of toxicology, from which the most prominent is the possibility of studying individual drug use histories by means of segmental analysis. This paper will review the unique role of hair as a complementary sample in documenting human exposure to drugs in the fields of clinical and forensic toxicology and workplace drug testing.

  17. An assessment of the natural radioactivity distribution and radiation hazard in soil samples from Qatar using high-resolution gamma-ray spectrometry

    NASA Astrophysics Data System (ADS)

    Al-Sulaiti, Huda; Al Mugren, K. S.; Bradley, D. A.; Regan, P. H.; Santawamaitre, T.; Malain, D.; Habib, A.; Nasir, Tabassum; Alkhomashi, N.; Al-Dahan, N.; Al-Dosari, M.; Bukhari, S.

    2017-11-01

    We establish baseline measurements for radioactivity concentration in the soil samples collected from the Qatarian peninsula. The work focused on the naturally occurring and technically enhanced levels of radiation associated with 235,8U and 232Th natural decay chains and the long-lived naturally occurring radionuclide 40K in 129 soil samples collected across the landscape of the State of Qatar. Three radiological distribution maps showing the activity concentrations of 226Ra, 232Th and 40K were constructed. Two soil samples were found to be elevated to the favour of 226Ra concentration and significantly above the average and global values. Notably, these samples were collected from an area within an oil field (NW Dukhan). The mean values of activity concentrations of 226Ra, 232Th and 40K for the full cohort of samples were found to be 17.2±1.6, 6.38±0.26 and 169±5 Bq/kg, respectively. These values lie within the expected range relative to the world average values in soil samples of 30, 35 and 400 Bq/kg, respectively.

  18. Moving environmental DNA methods from concept to practice for monitoring aquatic macroorganisms

    USGS Publications Warehouse

    Goldberg, Caren S.; Strickler, Katherine M.; Pilliod, David S.

    2015-01-01

    The discovery that macroorganisms can be detected from their environmental DNA (eDNA) in aquatic systems has immense potential for the conservation of biological diversity. This special issue contains 11 papers that review and advance the field of eDNA detection of vertebrates and other macroorganisms, including studies of eDNA production, transport, and degradation; sample collection and processing to maximize detection rates; and applications of eDNA for conservation using citizen scientists. This body of work is an important contribution to the ongoing efforts to take eDNA detection of macroorganisms from technical breakthrough to established, reliable method that can be used in survey, monitoring, and research applications worldwide. While the rapid advances in this field are remarkable, important challenges remain, including consensus on best practices for collection and analysis, understanding of eDNA diffusion and transport, and avoidance of inhibition in sample collection and processing. Nonetheless, as demonstrated in this special issue, eDNA techniques for research and monitoring are beginning to realize their potential for contributing to the conservation of biodiversity globally.

  19. A novel hybridization approach for detection of citrus viroids.

    PubMed

    Murcia, N; Serra, P; Olmos, A; Duran-Vila, N

    2009-04-01

    Citrus plants are natural hosts of several viroid species all belonging to the family Pospiviroidae. Previous attempts to detect viroids from field-grown species and cultivars yielded erratic results unless analyses were performed using Etrog citron a secondary bio-amplification host. To overcome the use of Etrog citron a number of RT-PCR approaches have been proposed with different degrees of success. Here we report the suitability of an easy to handle northern hybridization protocol for viroid detection of samples collected from field-grown citrus species and cultivars. The protocol involves: (i) Nucleic acid preparations from bark tissue samples collected from field-grown trees regardless of the growing season and storage conditions; (ii) Separation in 5% PAGE or 1% agarose, blotting to membrane and fixing; (iii) Hybridization with viroid-specific DIG-labelled probes and detection with anti-DIG-alkaline phosphatase conjugate and autoradiography with the CSPD substrate. The method has been tested with viroid-infected trees of sweet orange, lemon, mandarin, grapefruit, sour orange, Swingle citrumello, Tahiti lime and Mexican lime. This novel hybridization approach is extremely sensitive, easy to handle and shortens the time needed for reliable viroid indexing tests. The suitability of PCR generated DIG-labelled probes and the sensitivity achieved when the samples are separated and blotted from non-denaturing gels are discussed.

  20. Solid phase microextraction device using aerogel

    DOEpatents

    Miller, Fred S.; Andresen, Brian D.

    2005-06-14

    A sample collection substrate of aerogel and/or xerogel materials bound to a support structure is used as a solid phase microextraction (SPME) device. The xerogels and aerogels may be organic or inorganic and doped with metals or other compounds to target specific chemical analytes. The support structure is typically formed of a glass fiber or a metal wire (stainless steel or kovar). The devices are made by applying gel solution to the support structures and drying the solution to form aerogel or xerogel. Aerogel particles may be attached to the wet layer before drying to increase sample collection surface area. These devices are robust, stable in fields of high radiation, and highly effective at collecting gas and liquid samples while maintaining superior mechanical and thermal stability during routine use. Aerogel SPME devices are advantageous for use in GC/MS analyses due to their lack of interfering background and tolerance of GC thermal cycling.

  1. Method for preparing a solid phase microextraction device using aerogel

    DOEpatents

    Miller, Fred S [Bethel Island, CA; Andresen, Brian D [Livermore, CA

    2006-10-24

    A sample collection substrate of aerogel and/or xerogel materials bound to a support structure is used as a solid phase microextraction (SPME) device. The xerogels and aerogels may be organic or inorganic and doped with metals or other compounds to target specific chemical analytes. The support structure is typically formed of a glass fiber or a metal wire (stainless steel or kovar). The devices are made by applying gel solution to the support structures and drying the solution to form aerogel or xerogel. Aerogel particles may be attached to the wet layer before drying to increase sample collection surface area. These devices are robust, stable in fields of high radiation, and highly effective at collecting gas and liquid samples while maintaining superior mechanical and thermal stability during routine use. Aerogel SPME devices are advantageous for use in GC/MS analyses due to their lack of interfering background and tolerance of GC thermal cycling.

  2. Detection of Papaverine for the Possible Identification of Illicit Opium Cultivation.

    PubMed

    Mirsafavi, Rustin Y; Lai, Kristine; Kline, Neal D; Fountain, Augustus W; Meinhart, Carl D; Moskovits, Martin

    2017-02-07

    Papaverine is a non-narcotic alkaloid found endemically and uniquely in the latex of the opium poppy. It is normally refined out of the opioids that the latex is typically collected for, hence its presence in a sample is strong prima facie evidence that the carrier from whom the sample was collected is implicated in the mass cultivation of poppies or the collection and handling of their latex. We describe an analysis technique combining surface-enhanced Raman spectroscopy (SERS) with microfluidics for detecting papaverine at low concentrations and show that its SERS spectrum has unique spectroscopic features that allows its detection at low concentrations among typical opioids. The analysis requires approximately 2.5 min from sample loading to results, which is compatible with field use. The weak acid properties of papaverine hydrochloride were investigated, and Raman bands belonging to the protonated and unprotonated forms of the isoquinoline ring of papaverine were identified.

  3. Meteorites and Microbes: Meteorite Collection and Ice Sampling at Patriot Hills, Thiel Mountains, and South Pole, Antarctica

    NASA Technical Reports Server (NTRS)

    Sipiera, Paul P.; Hoover, Richard B.; Rose, M. Franklin (Technical Monitor)

    2000-01-01

    During the Antarctica 2000 Expedition, sponsored by the Planetary Studies Foundation, meteorites and ice microbiota were collected from the Patriot Hills, and Thiel Mountains of Antarctica and snow samples were at the South Pole. Psychrophilic and psychrotrophic microbiota were obtained from blue ice, cryoconite and ice-bubble systems. Twenty frozen meteorites were collected using aseptic techniques from the blue ice fields near the Moulton Escarpment of the Thiel Mountains (85 S, 94 W) and from the Morris Moraine of the Patriot Hills (80 S, 81 W) Ellsworth Mountains. These ice and meteorite samples are of potential significance to Astrobiology. They may help refine chemical and morphological biomarkers and refine characteristics of microbial life in one of the harshest environments on Earth. We discuss the Antarctica 2000 Expedition and provide preliminary results of the investigation of the meteorites and ice microbiota recovered.

  4. A portable molecular-sieve-based CO2 sampling system for radiocarbon measurements

    NASA Astrophysics Data System (ADS)

    Palonen, V.

    2015-12-01

    We have developed a field-capable sampling system for the collection of CO2 samples for radiocarbon-concentration measurements. Most target systems in environmental research are limited in volume and CO2 concentration, making conventional flask sampling hard or impossible for radiocarbon studies. The present system captures the CO2 selectively to cartridges containing 13X molecular sieve material. The sampling does not introduce significant under-pressures or significant losses of moisture to the target system, making it suitable for most environmental targets. The system also incorporates a significantly larger sieve container for the removal of CO2 from chambers prior to the CO2 build-up phase and sampling. In addition, both the CO2 and H2O content of the sample gas are measured continuously. This enables in situ estimation of the amount of collected CO2 and the determination of CO2 flux to a chamber. The portable sampling system is described in detail and tests for the reliability of the method are presented.

  5. A portable molecular-sieve-based CO2 sampling system for radiocarbon measurements.

    PubMed

    Palonen, V

    2015-12-01

    We have developed a field-capable sampling system for the collection of CO2 samples for radiocarbon-concentration measurements. Most target systems in environmental research are limited in volume and CO2 concentration, making conventional flask sampling hard or impossible for radiocarbon studies. The present system captures the CO2 selectively to cartridges containing 13X molecular sieve material. The sampling does not introduce significant under-pressures or significant losses of moisture to the target system, making it suitable for most environmental targets. The system also incorporates a significantly larger sieve container for the removal of CO2 from chambers prior to the CO2 build-up phase and sampling. In addition, both the CO2 and H2O content of the sample gas are measured continuously. This enables in situ estimation of the amount of collected CO2 and the determination of CO2 flux to a chamber. The portable sampling system is described in detail and tests for the reliability of the method are presented.

  6. Prevalence, types, and geographical distribution of Listeria monocytogenes from a survey of retail Queso Fresco and associated cheese processing plants and dairy farms in Sonora, Mexico.

    PubMed

    Moreno-Enriquez, R I; Garcia-Galaz, A; Acedo-Felix, E; Gonzalez-Rios, I H; Call, J E; Luchansky, J B; Diaz-Cinco, M E

    2007-11-01

    In the first part of this study, samples were collected from farms, cheese processing plants (CPPs), and retail markets located in various geographical areas of Sonora, Mexico, over a 12-month period during the summer of 2004 and winter of 2005. Four (all Queso Fresco [QF] from retail markets) of 349 total samples tested positive for Listeria monocytogenes (Lm). Of these four positive samples, three were collected in the northern region and one in the southern region of Sonora. Additionally, two were collected during the winter months, and two were collected during the summer months. For the second part of the study, a total of 39 samples from a farm, a CPP, and retail markets were collected and processed according to a combination of the Norma Oficial Mexicana NOM-143-SSA1-1995.10 method (NOM) and the U.S. Food and Drug Administration (FDA) Bacteriological Analytical Manual method, and 27 samples from these same locations were collected and processed according to the U.S. Department of Agriculture Food Safety and Inspection Service method (USDA-FSIS). The NOM-FDA method recovered the pathogen from 6 (15%) of 39 samples (one cheese and five product contact surfaces), while the USDA-FSIS method recovered the pathogen from 5 (18.5%) of 27 samples (all product contact surfaces). In addition, the 40 isolates recovered from the 15 total samples that tested positive for Lm grouped into five distinct pulsotypes that were ca. 60% related, as determined by pulsed-field gel electrophoresis analysis. The results of this study confirmed a 3.4% prevalence of Lm in QF collected from retail markets located in Sonora and no appreciable difference in the effectiveness of either the NOM-FDA or USDA-FSIS method to recover the pathogen from cheese or environmental samples.

  7. Monitoring nitrogen deposition in throughfall using ion exchange resin columns: a field test in the San Bernardino Mountains

    Treesearch

    Mark E. Fenn; Mark A. Poth

    2004-01-01

    Conventional throughfall collection methods are labor intensive and analytically expensive to implement at broad scales. This study was conducted to test an alternative approach requiring infrequent sample collection and a greatly reduced number of chemical analyses. The major objective of the study was to determine the feasibility of using ion exchange resin (IER) to...

  8. Fate and origin of 1,2-dichloropropane in an unconfined shallow aquifer

    USGS Publications Warehouse

    Tesoriero, A.J.; Loffler, F.E.; Liebscher, H.

    2001-01-01

    A shallow aquifer with different redox zones overlain by intensive agricultural activity was monitored for the occurrence of 1,2-dichloropropane (DCP) to assess the fate and origin of this pollutant. DCP was detected more frequently in groundwater samples collected in aerobic and nitrate-reducing zones than those collected from iron-reducing zones. Simulated DCP concentrations for groundwater entering an iron-reducing zone were calculated from a fate and transport model that included dispersion, sorption, and hydrolysis but not degradation. Simulated concentrations were well in excess of measured values, suggesting that microbial degradation occurred in the iron-reducing zone. Microcosm experiments were conducted using aquifer samples collected from iron-reducing and aerobic zones to evaluate the potential for microbial degradation of DCP and to explain field observations. Hydrogenolysis of DCP and production of monochlorinated propanes in microcosm experiments occurred only with aquifer materials collected from the iron-reducing zone, and no dechlorination was observed in microcosms established with aquifer materials collected from the aerobic zones. Careful analyses of the DCP/1,2,2-trichloropropane ratios in groundwater indicated that older fumigant formulations were responsible for the high levels of DCP present in this aquifer.A shallow aquifer with different redox zones overlain by intensive agricultural activity was monitored for the occurrence of 1,2-dichloropropane (DCP) to assess the fate and origin of this pollutant. DCP was detected more frequently in groundwater samples collected in aerobic and nitrate-reducing zones than those collected from iron-reducing zones. Simulated DCP concentrations for groundwater entering an iron-reducing zone were calculated from a fate and transport model that included dispersion, sorption, and hydrolysis but not degradation. Simulated concentrations were well in excess of measured values, suggesting that microbial degradation occurred in the iron-reducing zone. Microcosm experiments were conducted using aquifer samples collected from iron-reducing and aerobic zones to evaluate the potential for microbial degradation of DCP and to explain field observations. Hydrogenolysis of DCP and production of monochlorinated propanes in microcosm experiments occurred only with aquifer materials collected from the iron-reducing zone, and no dechlorination was observed in microcosms established with aquifer materials collected from the aerobic zones. Careful analyses of the DCP/1,2,2-trichloropropane ratios in groundwater indicated that older fumigant formulations were responsible for the high levels of DCP present in this aquifer.

  9. Quality of nutrient data from streams and ground water sampled during water years 1992-2001

    USGS Publications Warehouse

    Mueller, David K.; Titus, Cindy J.

    2005-01-01

    Proper interpretation of water-quality data requires consideration of the effects that bias and variability might have on measured constituent concentrations. In this report, methods are described to estimate the bias due to contamination of samples in the field or laboratory and the variability due to sample collection, processing, shipment, and analysis. Contamination can adversely affect interpretation of measured concentrations in comparison to standards or criteria. Variability can affect interpretation of small differences between individual measurements or mean concentrations. Contamination and variability are determined for nutrient data from quality-control samples (field blanks and replicates) collected as part of the National Water-Quality Assessment (NAWQA) Program during water years 1992-2001. Statistical methods are used to estimate the likelihood of contamination and variability in all samples. Results are presented for five nutrient analytes from stream samples and four nutrient analytes from ground-water samples. Ammonia contamination can add at least 0.04 milligram per liter in up to 5 percent of all samples. This could account for more than 22 percent of measured concentrations at the low range of aquatic-life criteria (0.18 milligram per liter). Orthophosphate contamination, at least 0.019 milligram per liter in up to 5 percent of all samples, could account for more than 38 percent of measured concentrations at the limit to avoid eutrophication (0.05 milligram per liter). Nitrite-plus-nitrate and Kjeldahl nitrogen contamination is less than 0.4 milligram per liter in 99 percent of all samples; thus there is no significant effect on measured concentrations of environmental significance. Sampling variability has little or no effect on reported concentrations of ammonia, nitrite-plus-nitrate, orthophosphate, or total phosphorus sampled after 1998. The potential errors due to sampling variability are greater for the Kjeldahl nitrogen analytes and for total phosphorus sampled before 1999. The uncertainty in a mean of 10 concentrations caused by sampling variability is within a small range (1 to 7 percent) for all nutrients. These results can be applied to interpretation of environmental data collected during water years 1992-2001 in 52 NAWQA study units.

  10. Towards robust and repeatable sampling methods in eDNA based studies.

    PubMed

    Dickie, Ian A; Boyer, Stephane; Buckley, Hannah; Duncan, Richard P; Gardner, Paul; Hogg, Ian D; Holdaway, Robert J; Lear, Gavin; Makiola, Andreas; Morales, Sergio E; Powell, Jeff R; Weaver, Louise

    2018-05-26

    DNA based techniques are increasingly used for measuring the biodiversity (species presence, identity, abundance and community composition) of terrestrial and aquatic ecosystems. While there are numerous reviews of molecular methods and bioinformatic steps, there has been little consideration of the methods used to collect samples upon which these later steps are based. This represents a critical knowledge gap, as methodologically sound field sampling is the foundation for subsequent analyses. We reviewed field sampling methods used for metabarcoding studies of both terrestrial and freshwater ecosystem biodiversity over a nearly three-year period (n = 75). We found that 95% (n = 71) of these studies used subjective sampling methods, inappropriate field methods, and/or failed to provide critical methodological information. It would be possible for researchers to replicate only 5% of the metabarcoding studies in our sample, a poorer level of reproducibility than for ecological studies in general. Our findings suggest greater attention to field sampling methods and reporting is necessary in eDNA-based studies of biodiversity to ensure robust outcomes and future reproducibility. Methods must be fully and accurately reported, and protocols developed that minimise subjectivity. Standardisation of sampling protocols would be one way to help to improve reproducibility, and have additional benefits in allowing compilation and comparison of data from across studies. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  11. Water-quality data from two agricultural drainage basins in northwestern Indiana and northeastern Illinois: I. Lagrangian and synoptic data, 1999-2002

    USGS Publications Warehouse

    Antweiler, Ronald C.; Smith, Richard L.; Voytek, Mary A.; Bohlke, John Karl; Richards, Kevin D.

    2005-01-01

    Methods of data collection and results of analyses are presented for Lagrangian and synoptic water-quality data collected from two agricultural drainages, the Iroquois River in northwestern Indiana and Sugar Creek in northwestern Indiana and northeastern Illinois. During six separate sampling trips, in April, June and September 1999, May 2000, September 2001 and April 2002, 152 discrete water samples were collected to characterize the water chemistry over the course of 2 to 4 days on each of these drainages. Data were collected for nutrients, major inorganic constituents, dissolved organic carbon, trace elements, dissolved gases, total bacterial cell counts, chlorophyll-a concentrations, and suspended sediment concentrations. In addition, field measurements of streamflow, pH, specific conductance, water temperature, and dissolved oxygen concentration were made during all trips except April 1999.

  12. Reconnaissance techniques for determining soil-gas radon concentrations: an example from Prince Georges County, Maryland

    USGS Publications Warehouse

    Reimer, G.M.

    1990-01-01

    Radon reconnaissance requires some special considerations because a large area must be covered in a short period of time and analyses must be made soon after collection because of Rn decay. A simple approach to collection and field analysis consists of a small-diameter probe pounded into the ground to a depth of at least 0.75 m. Analysis is by an alpha-scintillometer. Soil-gas samples collected along a traverse in Prince Georges County, Maryland, demonstrates the utility of the technique. The reconnaissance sampling revealed Rn soil-gas concentrations of up to 2500 pCi/L (picocuries per liter) indicating that the potential exists for indoor accumulations in excess of 4 pCi/L. -from Author

  13. Proceedings of conference XXXII; workshop on Future directions in evaluating earthquake hazards of Southern California

    USGS Publications Warehouse

    Brown, William M.; Kockelman, William J.; Ziony, Joseph I.

    1986-01-01

    Hydrologic data were collected at White Sands Missile Range, NM, in 1985. The total groundwater withdrawal in 1985 was 676,433 ,800 gallons. The 11 supply wells in the Post Headquarters well field produced 642,056,000 gallons, or about 95 percent of the total. The six Range area supply wells produced 34,377,800 gallons. The total groundwater withdrawal was 8,841,200 gallons less in 1985 than 1984. Water samples from six Post Headquarters supply wells were collected for major chemical analysis. Water samples from 19 other wells were collected for pH and specific-conductance analysis. Depth-to-water measurements in the Post Headquarters supply wells showed seasonal fluctuations as well as continued long-term declines. (USGS)

  14. High spatial variation in population size and symbiotic performance of Rhizobium leguminosarum bv. trifolii with white clover in New Zealand pasture soils.

    PubMed

    Wakelin, Steven; Tillard, Guyléne; van Ham, Robert; Ballard, Ross; Farquharson, Elizabeth; Gerard, Emily; Geurts, Rene; Brown, Matthew; Ridgway, Hayley; O'Callaghan, Maureen

    2018-01-01

    Biological nitrogen fixation through the legume-rhizobia symbiosis is important for sustainable pastoral production. In New Zealand, the most widespread and valuable symbiosis occurs between white clover (Trifolium repens L.) and Rhizobium leguminosarum bv. trifolii (Rlt). As variation in the population size (determined by most probable number assays; MPN) and effectiveness of N-fixation (symbiotic potential; SP) of Rlt in soils may affect white clover performance, the extent in variation in these properties was examined at three different spatial scales: (1) From 26 sites across New Zealand, (2) at farm-wide scale, and (3) within single fields. Overall, Rlt populations ranged from 95 to >1 x 108 per g soil, with variation similar at the three spatial scales assessed. For almost all samples, there was no relationship between rhizobia population size and ability of the population to fix N during legume symbiosis (SP). When compared with the commercial inoculant strain, the SP of soils ranged between 14 to 143% efficacy. The N-fixing ability of rhizobia populations varied more between samples collected from within a single hill country field (0.8 ha) than between 26 samples collected from diverse locations across New Zealand. Correlations between SP and calcium and aluminium content were found in all sites, except within a dairy farm field. Given the general lack of association between SP and MPN, and high spatial variability of SP at single field scale, provision of advice for treating legume seed with rhizobia based on field-average MPN counts needs to be carefully considered.

  15. High spatial variation in population size and symbiotic performance of Rhizobium leguminosarum bv. trifolii with white clover in New Zealand pasture soils

    PubMed Central

    Tillard, Guyléne; van Ham, Robert; Ballard, Ross; Farquharson, Elizabeth; Gerard, Emily; Geurts, Rene; Brown, Matthew; Ridgway, Hayley; O’Callaghan, Maureen

    2018-01-01

    Biological nitrogen fixation through the legume-rhizobia symbiosis is important for sustainable pastoral production. In New Zealand, the most widespread and valuable symbiosis occurs between white clover (Trifolium repens L.) and Rhizobium leguminosarum bv. trifolii (Rlt). As variation in the population size (determined by most probable number assays; MPN) and effectiveness of N-fixation (symbiotic potential; SP) of Rlt in soils may affect white clover performance, the extent in variation in these properties was examined at three different spatial scales: (1) From 26 sites across New Zealand, (2) at farm-wide scale, and (3) within single fields. Overall, Rlt populations ranged from 95 to >1 x 108 per g soil, with variation similar at the three spatial scales assessed. For almost all samples, there was no relationship between rhizobia population size and ability of the population to fix N during legume symbiosis (SP). When compared with the commercial inoculant strain, the SP of soils ranged between 14 to 143% efficacy. The N-fixing ability of rhizobia populations varied more between samples collected from within a single hill country field (0.8 ha) than between 26 samples collected from diverse locations across New Zealand. Correlations between SP and calcium and aluminium content were found in all sites, except within a dairy farm field. Given the general lack of association between SP and MPN, and high spatial variability of SP at single field scale, provision of advice for treating legume seed with rhizobia based on field-average MPN counts needs to be carefully considered. PMID:29489845

  16. Evaluation of the Sequential Spot Sampler (S3) for time-resolved measurement of PM2.5 sulfate and nitrate through lab and field measurements

    NASA Astrophysics Data System (ADS)

    Hecobian, A.; Evanoski-Cole, A.; Eiguren-Fernandez, A.; Sullivan, A. P.; Lewis, G. S.; Hering, S. V.; Collett, J. L., Jr.

    2016-02-01

    The Sequential Spot Sampler (S3), a newly developed instrument to collect aerosols for time-resolved chemical composition measurements, was evaluated in the laboratory and field for the measurement of particulate sulfate and nitrate. The S3 uses a multi-temperature condensation growth tube to grow individual aerosols to droplets which are then deposited as a ˜ 1 mm diameter dry spot at the end of the growth tube in a 100 µL well of a multi-well plate. The well plate advances automatically to provide a sequence of time-resolved samples. The collected aerosols are subsequently analyzed in the laboratory. The sample is concentrated during the collection process, and the laboratory extraction and analysis steps can be automated. The well plate, as received from the field, is placed onto a needle-based autosampler that adds liquid for sample extraction and injects sample extract from each well onto an ion chromatograph for analysis. Laboratory evaluation for sulfate and nitrate ions showed that poly ether ether ketone (PEEK) used as well plate material does not contribute any artifacts; a 60 min extraction procedure leads to the recovery of sulfate and nitrate from the dry spots at above 95 % extraction efficiency; and samples stored frozen and analyzed up to 23 months later show less than a 10 % change in sulfate and nitrate concentrations. The limit of detection was 0.5 µg m-3 for sulfate and 0.2 µg m-3 for nitrate for a 1 h sampling period. In a month-long field study conducted in southern California, two S3s were deployed alongside a URG denuder-filter-pack and a Particle-Into-Liquid Sampler combined with an Ion Chromatograph (PILS-IC). Collocated S3 sampler concentrations compared by linear regression show good agreement, with r2 = 0.99 and slope = 0.99 (±0.004) µg m-3 for sulfate and r2 = 0.99 and slope = 1.0 (±0.006) µg m-3 for nitrate. When compared to the URG denuder-filter-pack and the PILS-IC, the S3 sulfate and nitrate concentrations yielded correlations above 0.84 for the square of the correlation coefficient and regression slopes close to 1.

  17. Cosmic Dust in ~50 KG Blocks of Blue Ice from Cap-Prudhomme and Queen Alexandra Range, Antarctica

    NASA Astrophysics Data System (ADS)

    Maurette, M.; Cragin, J.; Taylor, S.

    1992-07-01

    Favorable Antarctic blue ice fields have produced a large number of meteorite finds because of the ice ablation concentration process (Cassidy et al., 1982). Such ice fields should also concentrate cosmic dust grains including both spherules and unmelted micrometeorites. Here we present preliminary results of concentrations of cosmic dust grains in ice from two very different Antarctic blue ice fields. The first sample (~60 kg) was collected in January 1987 from the surface of the blue ice field at Cap-Prudhomme (CP), near the French station of Dumont d'Urville, by a team from the "Laboratoire de Glaciologie du CNRS" (A. Barnola). The second sample (~50 kg), was retrieved from a meteorite stranding surface near the Queen Alexandra range (QUE) by a team (M. Burger, W. Cassidy, and R.Walker) of the ANSMET 1990 field expedition in Antarctica. Both samples were transported frozen to the laboratory where they were subdivided and processed. The CP sample was cut with a stainless steel saw into 4 pieces while the QUE sample, which had the top surface identified, was cut into three equal (~15 cm) horizontal layers to provide constituent variability with depth. All subsequent work on both samples was performed in a class 100 clean room using procedures developed by M. de Angelis and M. Maurette aimed at minimizing the loss of extraterrestrial particles. Pieces of both samples were cleaned by rinsing thoroughly with ultrapure water (Milli-O) and then melted in polyethylene containers in a microwave oven. Aliquots were decanted for chemical analysis and the remaining meltwater was filtered through stainless steel sieves for collection of large (>30 micrometers) particles. Using a 30X binocular microscope particles were hand picked for subsequent SEM/EDX analyses. Our initial objective was to compare the cosmic dust concentration in ice from the two locations. But this comparison was only partial because in the CP-ice, only magnetic spherules of >50 micrometers were studied whereas the QUE-ice studies included measurements of the depth variation of various characteristics, such as the size distribution and concentration of both cosmic spherules and unmelted chondritic micrometeorites (AMMs), the concentrations of grains in the ~1-10-micrometer size range, and the concentration of trace elements in the ice. In addition both magnetic and nonmagnetic particles were collected from the QUE-ice. The concentration of chondritic spherules 50 micrometers in size is similar at both locations: in the CP-ice 5 spherules were found in 40 kg of residual ice (after cleaning), and 7 spherules (including a nonmagnetic one) were recovered from 50kg of QUE-ice. The QUE sample contained 11 AMMs (including 3 grains with sizes ~30-50 micrometers) resulting in a ratio of unmelted to melted micrometeorites with sizes >50 micrometers (~1), which is much lower than the CP ratio of >5 (obtained for particles subsequently recovered from 360 tons of CP-ice). The QUE sample showed that particles >100 micrometers in size are found primarily within the top 15 m of ice while smaller particles are found in the bottom layers (30-50 cm). In contrast to CP-ice, QUE-ice contains many annealed stress cracks, that etch very quickly in water. Despite the very different glaciological and climatological regimes at the CP and QUE ice fields, concentrations of cosmic spherules are surprisingly similar. The ratio of AMMs to spherules does vary, however. The depth variations of the characteristics of cosmic dust grains trapped in the ~50-cm-thick top layer of a blue ice field are already very useful to select favorable zones to collect micrometeorites. In addition, they might provide insight into both climatic and ice flow parameters. Acknowledgements. We thank W.A. Cassidy and G. Crozaz for comments and R.M. Walker for his support and interest. REFERENCES. Cassidy W.A. and Rancitelli L.A. (1982) Am. Scientist 70, 156-164.

  18. New Magnetic and Geochemical Results on Topsoils of the Mexico City Metropolitan Area

    NASA Astrophysics Data System (ADS)

    Martínez-Pichar, E.; Soler-Arechalde, A. M.; Morton, O.; Hernandez, E.; Lozano-Santa-Cruz, R.; Gonzalez, G.; Beramendi, L.; Urrutia-Fucugauchi, J. H.

    2008-05-01

    The Metropolitan Area of Mexico city is a region well known for intense industrial and commercial activity. The potential sources of the heavy metal pollutants are assumed to be petroleum processing, production of iron material, manufacturing, coal combustion, commercial and automobile exhaust. New samples were collected from industrial, roadside, residential and public parks in the urban areas around the city and added to two previous field campaigns (2003 and 2005). Localities selected for the study represent, presumably, different heavy metal pollution levels and sources. At each sampling point, the top 2 cm layer of the soil profile was collected with a stainless steel trowel and stored in a plastic bag. The elements Fe, Cu and Zn concentrations were determined by EDXRF (Philips PW1400 apparatus) on bulk- sample pressed, boric-acid backed pellets. Metal concentrations of Pb, Ni, Cr, and V were analyzed by ICP-MS with a VG Elemental PQ3 instrument. Magnetic mineralogy in bulk soil samples was investigated by low-field susceptibility using a Kappabridge KLY2. Remanent magnetizations (ARM and IRM) and Hysteresis loops of micro samples had been carried out at room temperature. Bivariate analysis on different ratios of magnetic parameters was employed to characterize the pollution sources.

  19. INNOVATIVE TECHNOLOGY VERIFICATION REPORT XRF ...

    EPA Pesticide Factsheets

    The Elvatech, Ltd. ElvaX (ElvaX) x-ray fluorescence (XRF) analyzer distributed in the United States by Xcalibur XRF Services (Xcalibur), was demonstrated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation (SITE) Program. The field portion of the demonstration was conducted in January 2005 at the Kennedy Athletic, Recreational and Social Park (KARS) at Kennedy Space Center on Merritt Island, Florida. The demonstration was designed to collect reliable performance and cost data for the ElvaX analyzer and seven other commercially available XRF instruments for measuring trace elements in soil and sediment. The performance and cost data were evaluated to document the relative performance of each XRF instrument. This innovative technology verification report describes the objectives and the results of that evaluation and serves to verify the performance and cost of the ElvaX analyzer. Separate reports have been prepared for the other XRF instruments that were evaluated as part of the demonstration. The objectives of the evaluation included determining each XRF instrument’s accuracy, precision, sample throughput, and tendency for matrix effects. To fulfill these objectives, the field demonstration incorporated the analysis of 326 prepared samples of soil and sediment that contained 13 target elements. The prepared samples included blends of environmental samples from nine different sample collection sites as well as s

  20. Mobile field data acquisition in geosciences

    NASA Astrophysics Data System (ADS)

    Golodoniuc, Pavel; Klump, Jens; Reid, Nathan; Gray, David

    2016-04-01

    The Discovering Australia's Mineral Resources Program of CSIRO is conducting a study to develop novel methods and techniques to reliably define distal footprints of mineral systems under regolith cover in the Capricorn Orogen - the area that lies between two well-known metallogenic provinces of Pilbara and Yilgarn Cratons in Western Australia. The multidisciplinary study goes beyond the boundaries of a specific discipline and aims at developing new methods to integrate heterogeneous datasets to gain insight into the key indicators of mineralisation. The study relies on large regional datasets obtained from previous hydrogeochemical, regolith, and resistate mineral studies around known deposits, as well as new data obtained from the recent field sampling campaigns around areas of interest. With thousands of water, vegetation, rock and soil samples collected over the past years, it has prompted us to look at ways to standardise field sampling procedures and review the data acquisition process. This process has evolved over the years (Golodoniuc et al., 2015; Klump et al., 2015) and has now reached the phase where fast and reliable collection of scientific data in remote areas is possible. The approach is backed by a unified discipline-agnostic platform - the Federated Archaeological Information Management System (FAIMS). FAIMS is an open source framework for mobile field data acquisition, developed at the University of New South Wales for archaeological field data collection. The FAIMS framework can easily be adapted to a diverse range of scenarios, different kinds of samples, each with its own peculiarities, integration with GPS, and the ability to associate photographs taken with the device embedded camera with captured data. Three different modules have been developed so far, dedicated to geochemical water, plant and rock sampling. All modules feature automatic date and position recording, and reproduce the established data recording workflows. The rock sampling module also features an interactive GIS component allowing to enter field observations as annotations to a map. The open communication protocols and file formats used by FAIMS modules allow easy integration with existing spatial data infrastructures and third-party applications, such as ArcGIS. The remoteness of the focus areas in the Capricorn region required reliable mechanisms for data replication and an added level of redundancy. This was achieved through the use of the FAIMS Server without adding a tightly coupled dependency on it - the mobile devices could continue to work independently in the case the server fails. To support collaborative fieldwork, "FAIMS on a Truck" offers networked collaboration within a field team using mobile applications as asynchronous rich clients. The framework runs on compatible Android devices (e.g., tablets, smart phones) with the network infrastructure supported by a FAIMS Server. The server component is installed in a field vehicle to provide data synchronisation between multiple mobile devices, backup and data transfer. The data entry process was streamlined and followed the workflow that field crews were accustomed to with added data validation capabilities. The use of a common platform allowed us to adopt the framework within multiple disciplines, improve data acquisition times, and reduce human-introduced errors. We continue to work with other research groups and continue to explore the possibilities to adopt the technology in other applications, e.g., agriculture.

Top