Sample records for field screening technologies

  1. FIELD ANALYTICAL SCREENING PROGRAM: PCB METHOD - INNOVATIVE TECHNOLOGY REPORT

    EPA Science Inventory

    This innovative technology evaluation report (ITER) presents information on the demonstration of the U.S. Environmental Protection Agency (EPA) Region 7 Superfund Field Analytical Screening Program (FASP) method for determining polychlorinated biphenyl (PCB) contamination in soil...

  2. FIELD ANALYTICAL SCREENING PROGRAM: PCP METHOD - INNOVATIVE TECHNOLOGY EVALUATION REPORT

    EPA Science Inventory

    The Field Analytical Screening Program (FASP) pentachlorophenol (PCP) method uses a gas chromatograph (GC) equipped with a megabore capillary column and flame ionization detector (FID) and electron capture detector (ECD) to identify and quantify PCP. The FASP PCP method is design...

  3. New-type planar field emission display with superaligned carbon nanotube yarn emitter.

    PubMed

    Liu, Peng; Wei, Yang; Liu, Kai; Liu, Liang; Jiang, Kaili; Fan, Shoushan

    2012-05-09

    With the superaligned carbon nanotube yarn as emitter, we have fabricated a 16 × 16 pixel field emission display prototype by adopting screen printing and laser cutting technologies. A planar diode field emission structure has been adopted. A very sharp carbon nanotube yarn tip emitter can be formed by laser cutting. Low voltage phosphor was coated on the anode electrodes also by screen printing. With a specially designed circuit, we have demonstrated the dynamic character display with the field emission display prototype. The emitter material and fabrication technologies in this paper are both easy to scale up to large areas.

  4. Examining Pre-Service Teacher Views on the Implementation of Screen-Based Writing Instruction

    ERIC Educational Resources Information Center

    Tok, Mehmet

    2015-01-01

    Today, as new technological developments continue to emerge, education, like many other fields, is going through major changes. Technological developments are causing changes to many common concepts. In particular, studies that benefit from technology in the field of education are becoming increasingly widespread, opening the door for the…

  5. Furthering the reliable and valid measurement of mental health screening, diagnoses, treatment and outcomes through health information technology.

    PubMed

    Haberer, Jessica E; Trabin, Tom; Klinkman, Michael

    2013-01-01

    Measurement of mental health is challenging; however, many solutions may be found through the use of health information technology. This article reviews current approaches to measuring mental health, focusing on screening, diagnosis, treatment, and outcomes. It then identifies several key areas in which health information technology may advance the field and provide reliable and valid measurements that are readily available to and manageable for providers, as well as acceptable, feasible, and sustainable for selected populations. Although new technologies must overcome many challenges, including privacy, efficiency, cost, and scalability, it is an exciting and fast-growing field with many potential applications and clinical benefit. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. Cost-effectiveness of Different Diabetic Retinopathy Screening Modalities

    PubMed Central

    Pasquel, Francisco J.; Hendrick, Andrew M.; Ryan, Martha; Cason, Emily; Ali, Mohammed K.; Narayan, K. M. Venkat

    2015-01-01

    Current screening strategies aimed at detection of diabetic retinopathy (DR) historically have poor compliance, but advancements in technology can enable improved access to care. Nearly 80% of all persons with diabetes live in low- and middle-income countries (LMICs), highlighting the importance of a cost effective screening program. Establishing mechanisms to reach populations with geographic and financial barriers to access is essential to prevent visual disability. Teleretinal programs leverage technology to improve access and reduce cost. The quality of currently employed screening modalities depends on many variables including the instrument used, use of pupillary mydriasis, number of photographic fields, and the qualifications of the photographer and image interpreter. Recent telemedicine and newer technological approaches have been introduced, but data for these technologies is yet limited. We present results of a systematic review of studies evaluating cost-effectiveness of DR screening, and discuss potential relevance for LMICs. PMID:26719134

  7. FIELD DEMONSTRATION OF INNOVATIVE LEAK DETECTION/LOCATION TECHNOLOGIES COUPLED WITH WALL-THICKNESS SCREENING FOR WATER MAINS

    EPA Science Inventory

    The U.S. Environmental Protection Agency sponsored a large-scale field demonstration of innovative leak detection/location and condition assessment technologies on a 76-year old, 2,500-ft long, cement-lined, 24-in. cast iron water main in Louisville, KY from July through Septembe...

  8. CHOL-N-SOIL PCB TEST KIT, DEXSIL CORP. - INNOVATIVE TECHNOLOGY Evaluation REPORT

    EPA Science Inventory

    This innovative technology evaluation report (ITER) presents the evaluation of two field screening technologies for determining polychlorinated biphenyl (PCB) contamination in soil. The demonstration was conducted by PRC Environmental Management, Inc. (PRC), under contract to the...

  9. Evaluation of infrared brake screening technology : final report & appendices

    DOT National Transportation Integrated Search

    2000-12-01

    This report documents the results of a field evaluation of the InfraRed Inspection System (IRISystem). The objective of the evaluation was to determine the effectiveness of the IRISystem in enhancing the screening of commercial motor vehicles (CMVs) ...

  10. Current challenges and future perspectives of plant and agricultural biotechnology.

    PubMed

    Moshelion, Menachem; Altman, Arie

    2015-06-01

    Advances in understanding plant biology, novel genetic resources, genome modification, and omics technologies generate new solutions for food security and novel biomaterials production under changing environmental conditions. New gene and germplasm candidates that are anticipated to lead to improved crop yields and other plant traits under stress have to pass long development phases based on trial and error using large-scale field evaluation. Therefore, quantitative, objective, and automated screening methods combined with decision-making algorithms are likely to have many advantages, enabling rapid screening of the most promising crop lines at an early stage followed by final mandatory field experiments. The combination of novel molecular tools, screening technologies, and economic evaluation should become the main goal of the plant biotechnological revolution in agriculture. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. DEMONSTRATION BULLETIN: PCP IMMUNOASSAY TECHNOLOGIES - PENTA RISC BY ENSYS INC., PENTA RAPID BY OHMICRON CORP., ENVIROGARD BY MILLIPORE

    EPA Science Inventory

    The objectives of this demonstration were to test these field screening technologies for accuracy and precision in detecting Pentachlorophenol (PCP) levels in soil and water by comparing their results with those of a confirmatory laboratory. The three immunoassay technologies ...

  12. Rigorous Screening Technology for Identifying Suitable CO2 Storage Sites II

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    George J. Koperna Jr.; Vello A. Kuuskraa; David E. Riestenberg

    2009-06-01

    This report serves as the final technical report and users manual for the 'Rigorous Screening Technology for Identifying Suitable CO2 Storage Sites II SBIR project. Advanced Resources International has developed a screening tool by which users can technically screen, assess the storage capacity and quantify the costs of CO2 storage in four types of CO2 storage reservoirs. These include CO2-enhanced oil recovery reservoirs, depleted oil and gas fields (non-enhanced oil recovery candidates), deep coal seems that are amenable to CO2-enhanced methane recovery, and saline reservoirs. The screening function assessed whether the reservoir could likely serve as a safe, long-term CO2more » storage reservoir. The storage capacity assessment uses rigorous reservoir simulation models to determine the timing, ultimate storage capacity, and potential for enhanced hydrocarbon recovery. Finally, the economic assessment function determines both the field-level and pipeline (transportation) costs for CO2 sequestration in a given reservoir. The screening tool has been peer reviewed at an Electrical Power Research Institute (EPRI) technical meeting in March 2009. A number of useful observations and recommendations emerged from the Workshop on the costs of CO2 transport and storage that could be readily incorporated into a commercial version of the Screening Tool in a Phase III SBIR.« less

  13. Microfluidic cell chips for high-throughput drug screening

    PubMed Central

    Chi, Chun-Wei; Ahmed, AH Rezwanuddin; Dereli-Korkut, Zeynep; Wang, Sihong

    2016-01-01

    The current state of screening methods for drug discovery is still riddled with several inefficiencies. Although some widely used high-throughput screening platforms may enhance the drug screening process, their cost and oversimplification of cell–drug interactions pose a translational difficulty. Microfluidic cell-chips resolve many issues found in conventional HTS technology, providing benefits such as reduced sample quantity and integration of 3D cell culture physically more representative of the physiological/pathological microenvironment. In this review, we introduce the advantages of microfluidic devices in drug screening, and outline the critical factors which influence device design, highlighting recent innovations and advances in the field including a summary of commercialization efforts on microfluidic cell chips. Future perspectives of microfluidic cell devices are also provided based on considerations of present technological limitations and translational barriers. PMID:27071838

  14. Impact of a Generalizable Reminder System on Colorectal Cancer Screening in Diverse Primary Care Practices

    PubMed Central

    Nease, Donald E.; Ruffin, Mack T.; Klinkman, Michael S.; Jimbo, Masahito; Braun, Thomas M.; Underwood, Jennifer M.

    2015-01-01

    Background Computerized reminder systems (CRS) show promise for increasing preventive services such as colorectal cancer (CRC) screening. However, prior research has not evaluated a generalizable CRS across diverse, community primary care practices. We evaluated whether a generalizable CRS, ClinfoTracker, could improve screening rates for CRC in diverse primary care practices. Methods The study was a prospective trial to evaluate ClinfoTracker using historical control data in 12 Great Lakes Research In Practice Network community-based, primary care practices distributed from Southeast to Upper Peninsula Michigan. Our outcome measures were pre- and post-study practice-level CRC screening rates among patients seen during the 9-month study period. Ability to maintain the CRS was measured by days of reminder printing. Field notes were used to examine each practice’s cohesion and technology capabilities. Results All but one practice increased their CRC screening rates, ranging from 3.3% to 16.8% improvement. t tests adjusted for within practice correlation showed improvement in screening rates across all 12 practices, from 41.7% to 50.9%, P = 0.002. Technology capabilities impacted printing days (74% for high technology vs. 45% for low technology practices, P = 0.01), and cohesion demonstrated an impact trend for screening (15.3% rate change for high cohesion vs. 7.9% for low cohesion practices). Conclusions Implementing a generalizable CRS in diverse primary care practices yielded significant improvements in CRC screening rates. Technology capabilities are important in maintaining the system, but practice cohesion may have a greater influence on screening rates. This work has important implications for practices implementing reminder systems. PMID:18725836

  15. Screening and detection of elder abuse: Research opportunities and lessons learned from emergency geriatric care, intimate partner violence, and child abuse.

    PubMed

    Beach, Scott R; Carpenter, Christopher R; Rosen, Tony; Sharps, Phyllis; Gelles, Richard

    2016-01-01

    This article provides an overview of elder abuse screening and detection methods for community-dwelling and institutionalized older adults, including general issues and challenges for the field. Then, discussions of applications in emergency geriatric care, intimate partner violence (IPV), and child abuse are presented to inform research opportunities in elder abuse screening. The article provides descriptions of emerging screening and detection methods and technologies from the emergency geriatric care and IPV fields. We also discuss the variety of potential barriers to effective screening and detection from the viewpoint of the older adult, caregivers, providers, and the health care system, and we highlight the potential harms and unintended negative consequences of increased screening and mandatory reporting. We argue that research should continue on the development of valid screening methods and tools, but that studies of perceived barriers and potential harms of elder abuse screening among key stakeholders should also be conducted.

  16. ENVIRONMENTAL TECHNOLOGY VERIFICATION: Separation of Manure Solids from Flushed Swine Waste. Hoffland Environmental Inc. Drag Screen and Clarifier

    EPA Science Inventory

    Verification testing of the Hoffland Drag Screen and Clarifier was conducted at the North Carolina State University's Lake Wheeler Road Field Laboratory, in Raleigh, North Carolina. The farm is designed to operate as a research and teaching facility with the capacity for 250 so...

  17. TECHNOLOGIES FOR MONITORING AND MEASUREMENT ...

    EPA Pesticide Factsheets

    A demonstration of technologies for determining the presence of dioxin and dioxin-like compounds in soil and sediment was conducted under EPA's Superfund Innovative Technology Evaluation Program in Saginaw, Michigan in April 2004. This report describes the performance evaluation of CAPE Technologies DF-1 Dioxin/Furan and PCB TEQ Immunoassay Kits. The kits are immunoassay techniques that report the total toxicity equivalents (TEQ) of dioxin/furans and polychlorinated biphenyls (PCBs. The technology results were compared to high resolution mass spectrometry TEQ results generated using EPA Methods 1613B and 1668A.The CAPE Technologies kits generally reported data higher than the certified PE and reference laboratory values. The technologys estimated MDL was 12 to 33 pg/g TEQ. Results from this demonstration suggest that the CAPE Technologies kits could be an effective screening tool for determining sample results above and below 20 pg/g TEQ and even more effective as a screen for sample above and below 50 pg/g TEQ, particularly considering that both the cost ($59,234 vs. $398,029) and the time (3 weeks vs. 8 months) to analyze the 209 demonstration samples were significantly less than those of the reference laboratory. The objective of this program is to promote the acceptance and use of innovative field technologies by providing well-documented performance and cost data obtained from field demonstrations.

  18. Low-cost, smartphone based frequency doubling technology visual field testing using virtual reality (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Alawa, Karam A.; Sayed, Mohamed; Arboleda, Alejandro; Durkee, Heather A.; Aguilar, Mariela C.; Lee, Richard K.

    2017-02-01

    Glaucoma is the leading cause of irreversible blindness worldwide. Due to its wide prevalence, effective screening tools are necessary. The purpose of this project is to design and evaluate a system that enables portable, cost effective, smartphone based visual field screening based on frequency doubling technology. The system is comprised of an Android smartphone to display frequency doubling stimuli and handle processing, a Bluetooth remote for user input, and a virtual reality headset to simulate the exam. The LG Nexus 5 smartphone and BoboVR Z3 virtual reality headset were used for their screen size and lens configuration, respectively. The system is capable of running the C-20, N-30, 24-2, and 30-2 testing patterns. Unlike the existing system, the smartphone FDT tests both eyes concurrently by showing the same background to both eyes but only displaying the stimulus to one eye at a time. Both the Humphrey Zeiss FDT and the smartphone FDT were tested on five subjects without a history of ocular disease with the C-20 testing pattern. The smartphone FDT successfully produced frequency doubling stimuli at the correct spatial and temporal frequency. Subjects could not tell which eye was being tested. All five subjects preferred the smartphone FDT to the Humphrey Zeiss FDT due to comfort and ease of use. The smartphone FDT is a low-cost, portable visual field screening device that can be used as a screening tool for glaucoma.

  19. High content screening in microfluidic devices

    PubMed Central

    Cheong, Raymond; Paliwal, Saurabh; Levchenko, Andre

    2011-01-01

    Importance of the field Miniaturization is key to advancing the state-of-the-art in high content screening (HCS), in order to enable dramatic cost savings through reduced usage of expensive biochemical reagents and to enable large-scale screening on primary cells. Microfluidic technology offers the potential to enable HCS to be performed with an unprecedented degree of miniaturization. Areas covered in this review This perspective highlights a real-world example from the authors’ work of HCS assays implemented in a highly miniaturized microfluidic format. Advantages of this technology are discussed, including cost savings, high throughput screening on primary cells, improved accuracy, the ability to study complex time-varying stimuli, and ease of automation, integration, and scaling. What the reader will gain The reader will understand the capabilities of a new microfluidics-based platform for HCS, and the advantages it provides over conventional plate-based HCS. Take home message Microfluidics technology will drive significant advancements and broader usage and applicability of HCS in drug discovery. PMID:21852997

  20. High-quality and small-capacity e-learning video featuring lecturer-superimposing PC screen images

    NASA Astrophysics Data System (ADS)

    Nomura, Yoshihiko; Murakami, Michinobu; Sakamoto, Ryota; Sugiura, Tokuhiro; Matsui, Hirokazu; Kato, Norihiko

    2006-10-01

    Information processing and communication technology are progressing quickly, and are prevailing throughout various technological fields. Therefore, the development of such technology should respond to the needs for improvement of quality in the e-learning education system. The authors propose a new video-image compression processing system that ingeniously employs the features of the lecturing scene. While dynamic lecturing scene is shot by a digital video camera, screen images are electronically stored by a PC screen image capturing software in relatively long period at a practical class. Then, a lecturer and a lecture stick are extracted from the digital video images by pattern recognition techniques, and the extracted images are superimposed on the appropriate PC screen images by off-line processing. Thus, we have succeeded to create a high-quality and small-capacity (HQ/SC) video-on-demand educational content featuring the advantages: the high quality of image sharpness, the small electronic file capacity, and the realistic lecturer motion.

  1. Medical mentoring via the evolving world wide web.

    PubMed

    Jaffer, Usman; Vaughan-Huxley, Eyston; Standfield, Nigel; John, Nigel W

    2013-01-01

    Mentoring, for physicians and surgeons in training, is advocated as an essential adjunct in work-based learning, providing support in career and non-career related issues. The World Wide Web (WWW) has evolved, as a technology, to become more interactive and person centric, tailoring itself to the individual needs of the user. This changing technology may open new avenues to foster mentoring in medicine. DESIGN, SYSTEMATIC REVIEW, MAIN OUTCOME MEASURES: A search of the MEDLINE database from 1950 to 2012 using the PubMed interface, combined with manual cross-referencing was performed using the following strategy: ("mentors"[MeSH Terms] OR "mentors"[All Fields] OR "mentor"[All Fields]) AND ("internet"[MeSH Terms] OR "internet"[All Fields]) AND ("medicine"[MeSH Terms] OR "medicine"[All Fields]) AND ("humans"[MeSH Terms] AND English[lang]). Abstracts were screened for relevance (UJ) to the topic; eligibility for inclusion was simply on screening for relevance to online mentoring and web-based technologies. Forty-five papers were found, of which 16 were relevant. All studies were observational in nature. To date, all medical mentoring applications utilizing the World Wide Web have enjoyed some success limited by Web 1.0 and 2.0 technologies. With the evolution of the WWW through 1.0, 2.0 and 3.0 generations, the potential for meaningful tele- and distance mentoring has greatly improved. Some engagement has been made with these technological advancements, however further work is required to fully realize the potential of these technologies. Copyright © 2012 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  2. Hydrodynamic model of screen channel liquid acquisition devices for in-space cryogenic propellant management

    NASA Astrophysics Data System (ADS)

    Darr, Samuel Ryan

    Technologies that enable the storage and transfer of cryogenic propellants in space will be needed for the next generation vehicles that will carry humans to Mars. One of the candidate technologies is the screen channel liquid acquisition device (LAD), which uses a metal woven wire mesh to separate the liquid and vapor phases so that single-phase liquid propellant can be transferred in microgravity. The purpose of this work is to provide an accurate hydrodynamic model of the liquid flow through a screen channel LAD. Chapter 2 provides a derivation of the flow-through-screen (FTS) boundary condition. The final boundary condition more accurately represents the complex geometry of metal woven wire mesh than the current model used in the literature. The effect of thermal contraction on the screen geometry due to large temperature changes common in cryogenic systems is quantified in this chapter as well. Chapter 3 provides a two-dimensional (2-D) analytical solution of the velocity and pressure fields in a screen channel LAD. This solution, which accounts for non-uniform injection through the screen, is compared with the traditional 1-D model which assumes a constant, uniform injection velocity. Chapter 4 describes the setup and results of an experiment that measures both the velocity and pressure fields in a screen channel LAD in order to validate the 2-D model. Results show that the 2-D model performs best against the new data and historical data. With the improved FTS boundary condition and the 2-D model, the pressure drop of a screen channel LAD is described with excellent accuracy. The result of this work is a predictive tool that will instill confidence in the design of screen channel LADs for future in-space propulsion systems.

  3. [Current advances and future prospects of genome editing technology in the field of biomedicine.

    PubMed

    Sakuma, Tetsushi

    Genome editing technology can alter the genomic sequence at will, contributing the creation of cellular and animal models of human diseases including hereditary disorders and cancers, and the generation of the mutation-corrected human induced pluripotent stem cells for ex vivo regenerative medicine. In addition, novel approaches such as drug development using genome-wide CRISPR screening and cancer suppression using epigenome editing technology, which can change the epigenetic modifications in a site-specific manner, have also been conducted. In this article, I summarize the current advances and future prospects of genome editing technology in the field of biomedicine.

  4. The development of high-content screening (HCS) technology and its importance to drug discovery.

    PubMed

    Fraietta, Ivan; Gasparri, Fabio

    2016-01-01

    High-content screening (HCS) was introduced about twenty years ago as a promising analytical approach to facilitate some critical aspects of drug discovery. Its application has spread progressively within the pharmaceutical industry and academia to the point that it today represents a fundamental tool in supporting drug discovery and development. Here, the authors review some of significant progress in the HCS field in terms of biological models and assay readouts. They highlight the importance of high-content screening in drug discovery, as testified by its numerous applications in a variety of therapeutic areas: oncology, infective diseases, cardiovascular and neurodegenerative diseases. They also dissect the role of HCS technology in different phases of the drug discovery pipeline: target identification, primary compound screening, secondary assays, mechanism of action studies and in vitro toxicology. Recent advances in cellular assay technologies, such as the introduction of three-dimensional (3D) cultures, induced pluripotent stem cells (iPSCs) and genome editing technologies (e.g., CRISPR/Cas9), have tremendously expanded the potential of high-content assays to contribute to the drug discovery process. Increasingly predictive cellular models and readouts, together with the development of more sophisticated and affordable HCS readers, will further consolidate the role of HCS technology in drug discovery.

  5. A methodological overview on molecular preimplantation genetic diagnosis and screening: a genomic future?

    PubMed

    Vendrell, Xavier; Bautista-Llácer, Rosa

    2012-12-01

    The genetic diagnosis and screening of preimplantation embryos generated by assisted reproduction technology has been consolidated in the prenatal care framework. The rapid evolution of DNA technologies is tending to molecular approaches. Our intention is to present a detailed methodological view, showing different diagnostic strategies based on molecular techniques that are currently applied in preimplantation genetic diagnosis. The amount of DNA from one single, or a few cells, obtained by embryo biopsy is a limiting factor for the molecular analysis. In this sense, genetic laboratories have developed molecular protocols considering this restrictive condition. Nevertheless, the development of whole-genome amplification methods has allowed preimplantation genetic diagnosis for two or more indications simultaneously, like the selection of histocompatible embryos plus detection of monogenic diseases or aneuploidies. Moreover, molecular techniques have permitted preimplantation genetic screening to progress, by implementing microarray-based comparative genome hybridization. Finally, a future view of the embryo-genetics field based on molecular advances is proposed. The normalization, cost-effectiveness analysis, and new technological tools are the next topics for preimplantation genetic diagnosis and screening. Concomitantly, these additions to assisted reproduction technologies could have a positive effect on the schedules of preimplantation studies.

  6. [Technology and disciplinary fields: cytotechnicians and implementation of the Pap test in Brazil].

    PubMed

    Teixeira, Luiz Antonio; Pumar, Leticia

    2014-01-01

    The implementation of the Pap test as a primary technology in the control of cervical cancer in Brazil was the result of choices, agreements and disputes among certain professional groups, including physicians from various specialisations, pharmacists, biologists, biomedical scientists and cytotechnologists. The first part of the paper describes the process of formulating Brazil's first screening campaigns using the Pap smear, and the subsequent emergence of the profession of cytotechnology, whose practitioners interpret this test. Second, based on questions raised by international historiography in the field of science and technology, we explore in detail how the adoption of the Pap smear transpired within the Brazilian context, focussing on the debates among the various professional groups with an interest in the suitability of the test and on the relationships between the public and private healthcare sectors. We show that the professional career of cytotechnologists and the way in which the Pap smear has been implemented as a central technology for cervical cancer screening in Brazil have been shaped by the conflicting views of this technology held by different disciplines as well as by the relationship between these disciplines and labour market dynamics.

  7. Preparation of a YAG:Ce phosphor glass by screen-printing technology and its application in LED packaging.

    PubMed

    Yang, Liang; Chen, Mingxiang; Lv, Zhicheng; Wang, Simin; Liu, Xiaogang; Liu, Sheng

    2013-07-01

    A simple and practical method for preparing phosphor glass is proposed. Phosphor distribution and element analysis are investigated by optical microscope and field emission scanning electron microscope (FE-SEM). The phosphor particles dispersed in the matrix are vividly observed, and their distributions are uniform. Spectrum distribution and color coordinates dependent on the thickness of the screen-printed phosphor layer coupled with a blue light emitting diode (LED) chip are studied. The luminous efficacy of the 75 μm printed phosphor-layer phosphor glass packaged white LED is 81.24 lm/W at 350 mA. This study opens up many possibilities for applications using the phosphor glass on a selected chip in which emission is well absorbed by all phosphors. The screen-printing technique also offers possibilities for the design and engineering of complex phosphor layers on glass substrates. Phosphor screen-printing technology allows the realization of high stability and thermal conductivity for the phosphor layer. This phosphor glass method provides many possibilities for LED packing, including thin-film flip chip and remote phosphor technology.

  8. TECHNOLOGIES FOR MONITORING AND MEASUREMENT ...

    EPA Pesticide Factsheets

    A demonstration of technologies for determining the presence of dioxin and dioxin-like compounds in soil and sediment was conducted under EPA's Superfund Innovative Technology Evaluation Program in Saginaw, Michigan in April 2004. This report describes the performance evaluation of the Abraxis LLC Coplanar PCB Enzyme-Linked Immunosorbent Assay (ELISA) kit. The kit is an immunoassay technique that reports the total toxicity equivalents (TEQ) of polychlorinated biphenyls (PCBs). The technology results were compared to high resolution mass spectrometry TEQ results generated using EPA Method 1668A.Abraxis generally reported data that were higher than the reference laboratory TEQPCB values, with the exception of ultra-high level PCB samples [> 10,000 picogram/gram (pg/g) TEQ] where Abraxis reported values lower than the reference method. The technologys estimated MDL was 6 to 31 pg/g TEQPCB. Results from this demonstration suggest that the Abraxis kit could be an effective screening tool for screening sample concentrations above and below 50 pg/g TEQPCB, particularly considering that the cost ($22,668 vs. $184,449) and the time to analyze the 209 demonstration samples were significantly less than those of the reference laboratory. The objective of this program is to promote the acceptance and use of innovative field technologies by providing well-documented performance and cost data obtained from field demonstrations.

  9. Using Technology to Teach Content in a Student Teaching Experience (and as a First Year Teacher)

    ERIC Educational Resources Information Center

    Lemon, Cheryl

    2005-01-01

    This article describes how Cheryl Lemon, a biology teacher at Gateway Regional High School, integrated technology into appropriate curricular contexts during her field experiences as a preservice teacher. She used Web-based simulations, a projection screen, an interactive white board, and Flash-based interactivity in conjunction with direct…

  10. Value of screening endoscopy in evaluation of esophageal, gastric and colon cancers

    PubMed Central

    Ro, Tae H; Mathew, Michelle A; Misra, Subhasis

    2015-01-01

    Esophageal, gastric, and colorectal cancers are deadly diseases that continue to plague our world today. The value of screening endoscopy in evaluating these types of cancers is a critical area of discussion due to a potential reduction in morbidity and mortality. This article describes how to identify a good screening test and explains what are important criteria in the field of screening endoscopy. Furthermore, the current status and progress of screening endoscopy for esophageal, gastric, and colorectal cancer will be evaluated and discussed. Mass screening programs have not been implemented for esophageal and gastric carcinomas in those with average or low risk populations. However, studies of high-risk populations have found value and a cost-benefit in conducting screening endoscopy. Colorectal cancer, on the other hand, has had mass screening programs in place for many years due to the clear evidence of improved outcomes. As the role of endoscopy as a screening tool has continued to develop, newer technology and techniques have emerged to improve its utility. Many new image enhancement techniques and computer processing programs have shown promise and may have a significant role in the future of endoscopic screening. These developments are paving the way for improving the diagnostic and therapeutic capability of endoscopy in the field of gastroenterology. PMID:26361416

  11. Value of screening endoscopy in evaluation of esophageal, gastric and colon cancers.

    PubMed

    Ro, Tae H; Mathew, Michelle A; Misra, Subhasis

    2015-09-07

    Esophageal, gastric, and colorectal cancers are deadly diseases that continue to plague our world today. The value of screening endoscopy in evaluating these types of cancers is a critical area of discussion due to a potential reduction in morbidity and mortality. This article describes how to identify a good screening test and explains what are important criteria in the field of screening endoscopy. Furthermore, the current status and progress of screening endoscopy for esophageal, gastric, and colorectal cancer will be evaluated and discussed. Mass screening programs have not been implemented for esophageal and gastric carcinomas in those with average or low risk populations. However, studies of high-risk populations have found value and a cost-benefit in conducting screening endoscopy. Colorectal cancer, on the other hand, has had mass screening programs in place for many years due to the clear evidence of improved outcomes. As the role of endoscopy as a screening tool has continued to develop, newer technology and techniques have emerged to improve its utility. Many new image enhancement techniques and computer processing programs have shown promise and may have a significant role in the future of endoscopic screening. These developments are paving the way for improving the diagnostic and therapeutic capability of endoscopy in the field of gastroenterology.

  12. Hydrodynamic model of screen channel liquid acquisition devices for in-space cryogenic propellant management

    NASA Astrophysics Data System (ADS)

    Darr, S. R.; Camarotti, C. F.; Hartwig, J. W.; Chung, J. N.

    2017-01-01

    Technologies that enable the storage and transfer of cryogenic propellants in space will be needed for the next generation vehicles that will carry humans to Mars. One of the candidate technologies is the screen channel liquid acquisition device (LAD), which uses a metal woven wire mesh to separate the liquid and vapor phases so that single-phase liquid propellant can be transferred in microgravity. In this work, an experiment is carried out that provides measurements of the velocity and pressure fields in a screen channel LAD. These data are used to validate a new analytical solution of the liquid flow through a screen channel LAD. This hydrodynamic model, which accounts for non-uniform injection through the screen, is compared with the traditional pressure term summation model which assumes a constant, uniform injection velocity. Results show that the new model performs best against the new data and historical data. The velocity measurements inside the screen channel LAD are used to provide a more accurate velocity profile which further improves the new model. The result of this work is a predictive tool that will instill confidence in the design of screen channel LADs for future in-space propulsion systems.

  13. Detection of hidden explosives in different scenarios with the use of nuclear probes

    NASA Astrophysics Data System (ADS)

    Nebbia, G.; Pesente, S.; Lunardon, M.; Moretto, S.; Viesti, G.; Cinausero, M.; Barbui, M.; Fioretto, E.; Filippini, V.; Sudac, D.; Nađ, K.; Blagus, S.; Valković, V.

    2005-04-01

    The detection of landmines by using available technologies is a time consuming, expensive and extremely dangerous job, so that there is a need for a technological breakthrough in this field. Atomic and nuclear physics based sensors might offer new possibilities in de-mining. Technology and methods derived from the studies applied to the detection of landmines can be successfully applied to the screening of cargo in customs inspections.

  14. Modeling In Situ Bioremediation of Perchlorate-Contaminated Groundwater

    NASA Astrophysics Data System (ADS)

    Goltz, M. N.; Secody, R. E.; Huang, J.; Hatzinger, P. B.

    2007-12-01

    Perchlorate-contaminated groundwater is a significant national problem. An innovative technology was recently developed which uses a pair of dual-screened treatment wells to mix an electron donor into perchlorate- contaminated groundwater in order to effect in situ bioremediation of the perchlorate by indigenous perchlorate reducing bacteria (PRB) without the need to extract the contaminated water from the subsurface. The two treatment wells work in tandem to establish a groundwater recirculation zone in the subsurface. Electron donor is added and mixed into perchlorate-contaminated groundwater flowing through each well. The donor serves to stimulate biodegradation of the perchlorate by PRB in bioactive zones that form adjacent to the injection screens of the treatment wells. In this study, a model that simulates operation of the technology was calibrated using concentration data obtained from a field-scale technology evaluation project at a perchlorate-contaminated site. The model simulates transport of perchlorate, the electron donor (citrate, for this study), and competing electron acceptors (oxygen and nitrate) in the groundwater flow field induced by operation of the treatment well pair. A genetic algorithm was used to derive a set of best-fit model parameters to describe the perchlorate reduction kinetics in this field-scale evaluation project. The calibrated parameter values were then used to predict technology performance. The model qualitatively predicted the salient characteristics of the observed data. It appears the model may be a useful tool for designing and operating this technology at other perchlorate-contaminated sites.

  15. Advanced and tendencies in the development of display technologies

    NASA Astrophysics Data System (ADS)

    Kompanets, I. N.

    2006-06-01

    Advances and key display applications are discussed. Computer, compact mobile, TV and collective large screen displays are mentioned. Flat panel displays step on CRT devices to leave them behind in 2007. Materials, active matricies and applications of bright radiative field emission and organic LED displays are developing successively and pressing other technologies to be used in photo-cameras, cellular phones, auto-cars and avionics. Progress in flexible screens can substantially extend the display design and application soon. 3D display systems are under intensive development, and laser is an important unit in some vaiants of holographic and volumetric 3D displays. Value forecast of different display markets is presented.

  16. A Wearable Textile 2D Touchpad Sensor Based on Screen-Printing Technology.

    PubMed

    Ferri, Josue; Lidón-Roger, Jose Vicente; Moreno, Jorge; Martinez, Gabriel; Garcia-Breijo, Eduardo

    2017-12-20

    Among many of the designs used in the detection of 2D gestures for portable technology, the touchpad is one of the most complex and with more functions to implement. Its development has undergone a great push due to its use in displays, but it is not widely used with other technologies. Its application on textiles could allow a wide range of applications in the field of medicine, sports, etc. Obtaining a flexible, robust touchpad with good response and low cost is one of the objectives of this work. A textile touchpad based on a diamond pattern design using screen printing technology has been developed. This technology is widely used in the textile industry and therefore does not require heavy investments. The developed prototypes were analyzed using a particular controller for projected capacitive technologies (pro-cap), which is the most used in gesture detection. Two different designs were used to obtain the best configuration, obtaining a good result in both cases.

  17. A Wearable Textile 2D Touchpad Sensor Based on Screen-Printing Technology

    PubMed Central

    Ferri, Josue; Moreno, Jorge; Martinez, Gabriel

    2017-01-01

    Among many of the designs used in the detection of 2D gestures for portable technology, the touchpad is one of the most complex and with more functions to implement. Its development has undergone a great push due to its use in displays, but it is not widely used with other technologies. Its application on textiles could allow a wide range of applications in the field of medicine, sports, etc. Obtaining a flexible, robust touchpad with good response and low cost is one of the objectives of this work. A textile touchpad based on a diamond pattern design using screen printing technology has been developed. This technology is widely used in the textile industry and therefore does not require heavy investments. The developed prototypes were analyzed using a particular controller for projected capacitive technologies (pro-cap), which is the most used in gesture detection. Two different designs were used to obtain the best configuration, obtaining a good result in both cases. PMID:29261167

  18. Graphic products used in the evaluation of traditional and emerging remote sensing technologies for the detection of fugitive contamination at selected superfund hazardous waste sites

    USGS Publications Warehouse

    Slonecker, E. Terrence; Fisher, Gary B.

    2011-01-01

    This report presents the overhead imagery and field sampling results used to prepare U.S. Geological Survey Open-File Report 2011-1050, 'Evaluation of Traditional and Emerging Remote Sensing Technologies for the Detection of Fugitive Contamination at Selected Superfund Hazardous Waste Sites'. These graphic products were used in the evaluation of remote sensing technology in postclosure monitoring of hazardous waste sites and represent an ongoing research effort. Soil sampling results presented here were accomplished with field portable x-ray fluoresence (XRF) technology and are used as screening tools only representing the current conditions of metals and other contaminants at selected Superfund hazardous waste sites.

  19. Screening applications in drug discovery based on microfluidic technology

    PubMed Central

    Eribol, P.; Uguz, A. K.; Ulgen, K. O.

    2016-01-01

    Microfluidics has been the focus of interest for the last two decades for all the advantages such as low chemical consumption, reduced analysis time, high throughput, better control of mass and heat transfer, downsizing a bench-top laboratory to a chip, i.e., lab-on-a-chip, and many others it has offered. Microfluidic technology quickly found applications in the pharmaceutical industry, which demands working with leading edge scientific and technological breakthroughs, as drug screening and commercialization are very long and expensive processes and require many tests due to unpredictable results. This review paper is on drug candidate screening methods with microfluidic technology and focuses specifically on fabrication techniques and materials for the microchip, types of flow such as continuous or discrete and their advantages, determination of kinetic parameters and their comparison with conventional systems, assessment of toxicities and cytotoxicities, concentration generations for high throughput, and the computational methods that were employed. An important conclusion of this review is that even though microfluidic technology has been in this field for around 20 years there is still room for research and development, as this cutting edge technology requires ingenuity to design and find solutions for each individual case. Recent extensions of these microsystems are microengineered organs-on-chips and organ arrays. PMID:26865904

  20. Screening applications in drug discovery based on microfluidic technology.

    PubMed

    Eribol, P; Uguz, A K; Ulgen, K O

    2016-01-01

    Microfluidics has been the focus of interest for the last two decades for all the advantages such as low chemical consumption, reduced analysis time, high throughput, better control of mass and heat transfer, downsizing a bench-top laboratory to a chip, i.e., lab-on-a-chip, and many others it has offered. Microfluidic technology quickly found applications in the pharmaceutical industry, which demands working with leading edge scientific and technological breakthroughs, as drug screening and commercialization are very long and expensive processes and require many tests due to unpredictable results. This review paper is on drug candidate screening methods with microfluidic technology and focuses specifically on fabrication techniques and materials for the microchip, types of flow such as continuous or discrete and their advantages, determination of kinetic parameters and their comparison with conventional systems, assessment of toxicities and cytotoxicities, concentration generations for high throughput, and the computational methods that were employed. An important conclusion of this review is that even though microfluidic technology has been in this field for around 20 years there is still room for research and development, as this cutting edge technology requires ingenuity to design and find solutions for each individual case. Recent extensions of these microsystems are microengineered organs-on-chips and organ arrays.

  1. Automation, parallelism, and robotics for proteomics.

    PubMed

    Alterovitz, Gil; Liu, Jonathan; Chow, Jijun; Ramoni, Marco F

    2006-07-01

    The speed of the human genome project (Lander, E. S., Linton, L. M., Birren, B., Nusbaum, C. et al., Nature 2001, 409, 860-921) was made possible, in part, by developments in automation of sequencing technologies. Before these technologies, sequencing was a laborious, expensive, and personnel-intensive task. Similarly, automation and robotics are changing the field of proteomics today. Proteomics is defined as the effort to understand and characterize proteins in the categories of structure, function and interaction (Englbrecht, C. C., Facius, A., Comb. Chem. High Throughput Screen. 2005, 8, 705-715). As such, this field nicely lends itself to automation technologies since these methods often require large economies of scale in order to achieve cost and time-saving benefits. This article describes some of the technologies and methods being applied in proteomics in order to facilitate automation within the field as well as in linking proteomics-based information with other related research areas.

  2. The use of technology in Suicide Prevention.

    PubMed

    Larsen, Mark E; Cummins, Nicholas; Boonstra, Tjeerd W; O'Dea, Bridianne; Tighe, Joe; Nicholas, Jennifer; Shand, Fiona; Epps, Julien; Christensen, Helen

    2015-01-01

    Suicide is one of the leading causes of death globally, and is notably a significant cause of death amongst young people. A suicide outcome is a complex combination of personal, social, and health factors, and therefore suicide prevention is a challenge, requiring a systems approach incorporating public health strategies, screening at-risk individuals, targeted interventions, and follow-up for suicide survivors and those bereaved by suicide. Engineering practice has been implicated in the hindrance of the adoption of suicide prevention strategies, such as installing safety barriers at the Golden Gate Bridge, however technological developments offer new opportunities in suicide prevention, and the potential to reduce the number of deaths by suicide. We present an overview of current technological developments which are facilitating research in the field of suicide prevention, including multiple modes of screening such as network analysis of mobile-phone collected connectivity data, automatic detection of suicidality from social media content, and crisis detection from acoustic variability in speech patterns. The current field of mhealth apps for suicide prevention is assessed, and an innovative app for an Indigenous population is presented. From this overview, future challenges - technical and ethical - are discussed.

  3. Two-Way Radio Modem Data Transfer for Newborn Hearing Screening Devices.

    PubMed

    Matulat, Peter; Lepper, Ingo; Böttcher, Peter; Parfitt, Ross; Oswald, Hans; Am Zehnhoff-Dinnesen, Antoinette; Deuster, Dirk

    2017-01-01

    The success of a newborn hearing screening program depends on successful tracking and follow-up to ensure that children who have had positive screening results in the first few days of life receive appropriate and timely diagnostic and intervention services. The easy availability, through a suitable infrastructure, of the data necessary for the tracking, diagnosis, and care of children concerned is a major key to enhancing the quality and efficiency of newborn hearing screening programs. Two systems for the automated two-way transmission of newborn hearing screening and configuration data, based on mobile communication technology, for the screening devices MADSEN AccuScreen ® and Natus Echo-Screen ® were developed and tested in a field study. Radio modem connections were compared with conventional analogue modem transmissions from Natus Echo-Screen devices for duration, transmission rate, number of lost connections, and frequency of use. The average session duration was significantly lower with the MADSEN AccuScreen (12 s) and Natus Echo-Screen both with radio modem (15 s) than the Natus Echo-Screen with analogue modem (108 s). The transmission rate was significantly higher (898 and 1,758 vs. 181 bytes/s) for the devices with radio modems. Both radio modem devices had significantly lower rates of broken connections after initial connection (2.1 and 0.9 vs. 5.5%). An increase in the frequency of data transmission from the clinics with mobile radio devices was found. The use of mobile communication technology in newborn hearing screening devices offers improvements in the average session duration, transmission rate, and reliability of the connection over analogue solutions. We observed a behavioral change in clinical staff using the new technology: the data exchange with the tracking center is more often used. The requirements for on-site support were reduced. These savings outweigh the small increase in costs for the Internet service provider.

  4. Natural 3D content on glasses-free light-field 3D cinema

    NASA Astrophysics Data System (ADS)

    Balogh, Tibor; Nagy, Zsolt; Kovács, Péter Tamás.; Adhikarla, Vamsi K.

    2013-03-01

    This paper presents a complete framework for capturing, processing and displaying the free viewpoint video on a large scale immersive light-field display. We present a combined hardware-software solution to visualize free viewpoint 3D video on a cinema-sized screen. The new glasses-free 3D projection technology can support larger audience than the existing autostereoscopic displays. We introduce and describe our new display system including optical and mechanical design considerations, the capturing system and render cluster for producing the 3D content, and the various software modules driving the system. The indigenous display is first of its kind, equipped with front-projection light-field HoloVizio technology, controlling up to 63 MP. It has all the advantages of previous light-field displays and in addition, allows a more flexible arrangement with a larger screen size, matching cinema or meeting room geometries, yet simpler to set-up. The software system makes it possible to show 3D applications in real-time, besides the natural content captured from dense camera arrangements as well as from sparse cameras covering a wider baseline. Our software system on the GPU accelerated render cluster, can also visualize pre-recorded Multi-view Video plus Depth (MVD4) videos on this light-field glasses-free cinema system, interpolating and extrapolating missing views.

  5. [Progress in stem cells and regenerative medicine].

    PubMed

    Wang, Libin; Zhu, He; Hao, Jie; Zhou, Qi

    2015-06-01

    Stem cells have the ability to differentiate into all types of cells in the body and therefore have great application potential in regenerative medicine, in vitro disease modelling and drug screening. In recent years, stem cell technology has made great progress, and induced pluripotent stem cell technology revolutionizes the whole stem cell field. At the same time, stem cell research in our country has also achieved great progress and becomes an indispensable power in the worldwide stem cell research field. This review mainly focuses on the research progress in stem cells and regenerative medicine in our country since the advent of induced pluripotent stem cell technology, including induced pluripotent stem cells, transdifferentiation, haploid stem cells, and new gene editing tools.

  6. Smart DNA Fabrication Using Sound Waves: Applying Acoustic Dispensing Technologies to Synthetic Biology.

    PubMed

    Kanigowska, Paulina; Shen, Yue; Zheng, Yijing; Rosser, Susan; Cai, Yizhi

    2016-02-01

    Acoustic droplet ejection (ADE) technology uses focused acoustic energy to transfer nanoliter-scale liquid droplets with high precision and accuracy. This noncontact, tipless, low-volume dispensing technology minimizes the possibility of cross-contamination and potentially reduces the costs of reagents and consumables. To date, acoustic dispensers have mainly been used in screening libraries of compounds. In this paper, we describe the first application of this powerful technology to the rapidly developing field of synthetic biology, for DNA synthesis and assembly at the nanoliter scale using a Labcyte Echo 550 acoustic dispenser. We were able to successfully downscale PCRs and the popular one-pot DNA assembly methods, Golden Gate and Gibson assemblies, from the microliter to the nanoliter scale with high assembly efficiency, which effectively cut the reagent cost by 20- to 100-fold. We envision that acoustic dispensing will become an instrumental technology in synthetic biology, in particular in the era of DNA foundries. © 2015 Society for Laboratory Automation and Screening.

  7. Advances in chemical sensing technologies for VOCs in breath for security/threat assessment, illicit drug detection, and human trafficking activity.

    PubMed

    Giannoukos, S; Agapiou, A; Taylor, S

    2018-01-17

    On-site chemical sensing of compounds associated with security and terrorist attacks is of worldwide interest. Other related bio-monitoring topics include identification of individuals posing a threat from illicit drugs, explosive manufacturing, as well as searching for victims of human trafficking and collapsed buildings. The current status of field analytical technologies is directed towards the detection and identification of vapours and volatile organic compounds (VOCs). Some VOCs are associated with exhaled breath, where research is moving from individual breath testing (volatilome) to cell breath (microbiome) and most recently to crowd breath metabolites (exposome). In this paper, an overview of field-deployable chemical screening technologies (both stand-alone and those with portable characteristics) is given with application to early detection and monitoring of human exposome in security operations. On-site systems employed in exhaled breath analysis, i.e. mass spectrometry (MS), optical spectroscopy and chemical sensors are reviewed. Categories of VOCs of interest include (a) VOCs in human breath associated with exposure to threat compounds, and (b) VOCs characteristic of, and associated with, human body odour (e.g. breath, sweat). The latter are relevant to human trafficking scenarios. New technological approaches in miniaturised detection and screening systems are also presented (e.g. non-scanning digital light processing linear ion trap MS (DLP-LIT-MS), nanoparticles, mid-infrared photo-acoustic spectroscopy and hyphenated technologies). Finally, the outlook for rapid and precise, real-time field detection of threat traces in exhaled breath is revealed and discussed.

  8. Ethical issues in pediatric genetic testing and screening.

    PubMed

    Botkin, Jeffrey R

    2016-12-01

    Developments in genetic test technologies enable a detailed analysis of the genomes of individuals across the range of human development from embryos to adults with increased precision and lower cost. These powerful technologies raise a number of ethical issues in pediatrics, primarily because of the frequent lack of clinical utility of genetic information, the generation of secondary results and questions over the proper scope of parental authority for testing. Several professional organizations in the fields of genetics and pediatrics have published new guidance on the ethical, legal, and policy issues relevant to genetic testing in children. The roles of predictive testing for adult-onset conditions, the management of secondary findings and the role of informed consent for newborn screening remain controversial. However, research and experience are not demonstrating serious adverse psychosocial impacts from genetic testing and screening in children. The use of these technologies is expanding with the notion that the personal utility of test results, rather than clinical utility, may be sufficient to justify testing. The use of microarray and genome sequencing technologies is expanding in the care of children. More deference to parental decision-making is evolving in contexts wherein information and counseling can be made readily available.

  9. Technologies for Single-Cell Isolation

    PubMed Central

    Gross, Andre; Schoendube, Jonas; Zimmermann, Stefan; Steeb, Maximilian; Zengerle, Roland; Koltay, Peter

    2015-01-01

    The handling of single cells is of great importance in applications such as cell line development or single-cell analysis, e.g., for cancer research or for emerging diagnostic methods. This review provides an overview of technologies that are currently used or in development to isolate single cells for subsequent single-cell analysis. Data from a dedicated online market survey conducted to identify the most relevant technologies, presented here for the first time, shows that FACS (fluorescence activated cell sorting) respectively Flow cytometry (33% usage), laser microdissection (17%), manual cell picking (17%), random seeding/dilution (15%), and microfluidics/lab-on-a-chip devices (12%) are currently the most frequently used technologies. These most prominent technologies are described in detail and key performance factors are discussed. The survey data indicates a further increasing interest in single-cell isolation tools for the coming years. Additionally, a worldwide patent search was performed to screen for emerging technologies that might become relevant in the future. In total 179 patents were found, out of which 25 were evaluated by screening the title and abstract to be relevant to the field. PMID:26213926

  10. Technologies for Single-Cell Isolation.

    PubMed

    Gross, Andre; Schoendube, Jonas; Zimmermann, Stefan; Steeb, Maximilian; Zengerle, Roland; Koltay, Peter

    2015-07-24

    The handling of single cells is of great importance in applications such as cell line development or single-cell analysis, e.g., for cancer research or for emerging diagnostic methods. This review provides an overview of technologies that are currently used or in development to isolate single cells for subsequent single-cell analysis. Data from a dedicated online market survey conducted to identify the most relevant technologies, presented here for the first time, shows that FACS (fluorescence activated cell sorting) respectively Flow cytometry (33% usage), laser microdissection (17%), manual cell picking (17%), random seeding/dilution (15%), and microfluidics/lab-on-a-chip devices (12%) are currently the most frequently used technologies. These most prominent technologies are described in detail and key performance factors are discussed. The survey data indicates a further increasing interest in single-cell isolation tools for the coming years. Additionally, a worldwide patent search was performed to screen for emerging technologies that might become relevant in the future. In total 179 patents were found, out of which 25 were evaluated by screening the title and abstract to be relevant to the field.

  11. Induced pluripotent stem cells for regenerative cardiovascular therapies and biomedical discovery.

    PubMed

    Nsair, Ali; MacLellan, W Robb

    2011-04-30

    The discovery of induced pluripotent stem cells (iPSC) has, in the short time since their discovery, revolutionized the field of stem cell biology. This technology allows the generation of a virtually unlimited supply of cells with pluripotent potential similar to that of embryonic stem cells (ESC). However, in contrast to ESC, iPSC are not subject to the same ethical concerns and can be easily generated from living individuals. For the first time, patient-specific iPSC can be generated and offer a supply of genetically identical cells that can be differentiated into all somatic cell types for potential use in regenerative therapies or drug screening and testing. As the techniques for generation of iPSC lines are constantly evolving, new uses for human iPSC are emerging from in-vitro disease modeling to high throughput drug discovery and screening. This technology promises to revolutionize the field of medicine and offers new hope for understanding and treatment of numerous diseases. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. Screening Electronic Health Record-Related Patient Safety Reports Using Machine Learning.

    PubMed

    Marella, William M; Sparnon, Erin; Finley, Edward

    2017-03-01

    The objective of this study was to develop a semiautomated approach to screening cases that describe hazards associated with the electronic health record (EHR) from a mandatory, population-based patient safety reporting system. Potentially relevant cases were identified through a query of the Pennsylvania Patient Safety Reporting System. A random sample of cases were manually screened for relevance and divided into training, testing, and validation data sets to develop a machine learning model. This model was used to automate screening of remaining potentially relevant cases. Of the 4 algorithms tested, a naive Bayes kernel performed best, with an area under the receiver operating characteristic curve of 0.927 ± 0.023, accuracy of 0.855 ± 0.033, and F score of 0.877 ± 0.027. The machine learning model and text mining approach described here are useful tools for identifying and analyzing adverse event and near-miss reports. Although reporting systems are beginning to incorporate structured fields on health information technology and the EHR, these methods can identify related events that reporters classify in other ways. These methods can facilitate analysis of legacy safety reports by retrieving health information technology-related and EHR-related events from databases without fields and controlled values focused on this subject and distinguishing them from reports in which the EHR is mentioned only in passing. Machine learning and text mining are useful additions to the patient safety toolkit and can be used to semiautomate screening and analysis of unstructured text in safety reports from frontline staff.

  13. Inter-cusp Ion and Electron Transport in a Nstar-derivative Ion Thruster

    NASA Technical Reports Server (NTRS)

    Foster, John E.

    2001-01-01

    Diffusion of electrons and ions to anode surfaces between the magnetic cusps of a NASA Solar Electric Propulsion Technology Application Readiness ion thruster has been characterized. Ion flux measurements were made at the anode and at the screen grid electrode. The measurements indicated that the average ion current density at the anode and at the screen grid were approximately equal. Additionally, it was found that the electron flux to the anode between cusps is best described by the classical cross-field diffusion coefficient.

  14. Ion and Electron Transport in an Nstar-derivative Ion Thruster. Revised

    NASA Technical Reports Server (NTRS)

    Foster, John E.

    2001-01-01

    Diffusion of electrons and ions to anode surfaces between the magnetic cusps of a NASA Solar Electric Propulsion Technology Application Readiness ion thruster has been characterized. Ion flux measurements were made at the anode and at the screen grid electrode. The measurements indicated that the average ion current density at the anode and at the screen grid were approximately equal. Additionally, it was found that the electron flux to the anode between cusps is best described by the classical cross-field diffusion coefficient.

  15. "Psychogeritechnology" in Japan: Exemplars from a super-aged society.

    PubMed

    Leroi, Iracema; Watanabe, Kentaro; Hird, Nick; Sugihara, Taro

    2018-05-31

    The burgeoning field of gerontechnology, which is the interdisciplinary field of applying technology to ageing issues, has focused primarily on "active ageing" and maintaining independence for older adults. To date, there has been less focus on people who develop dementia. Here, we argue for the field of gerontechnology to have a greater emphasis on clinical applications for dementia. This can be captured under the rubric of "psychogeritechnology," a term we have coined to describe the range of technology approaches to the prevention, prediction, screening, assessment, diagnosis, management, and monitoring of people at risk of, or living with, dementia. Using Japan as the world's leading "super-aged' nation as a paradigm, the purpose of this paper is to provide a narrative review of the use of innovative technology for the diagnosis, management and support of people at risk of, or living with, dementia. By following the "life course" of dementia, we will use clinical exemplars and case studies of psychogeritechnological applications from a Japanese context, specific to each stage of dementia, from the preclinical to the advanced stage. In the preclinical stage, the focus will be on prevention and early detection of degenerative cognitive-functional trajectories. In the early-stage of dementia, we will outline examples of screening, assessment, diagnosis, and clinical monitoring, as well as the use of technology to support independent living and autonomy. In the moderate stage, examples of safety monitoring systems, and assistive technology to foster independence, quality of life will be outlined. Finally, in the advanced stage of dementia, our focus will be on assistive technology in the care home setting, and the need to foster secure and efficient communication among care providers. We will discuss these applications in terms of the evolution of the "technological roadmap" for dementia, and the need for a theoretical underpinning for the field, a meaningful and flexible evaluation framework, and consideration of the "wider perspective" including safety-critical issues, ethical issues, and the relation to policy and health economics. Japan, as a rapidly ageing society, is on the forefront of developing technology to support people with dementia. The new field of psychogeritechnology must harness the potential of such developments, while furthering the methodology to implement and evaluate the changes. Copyright © 2018 John Wiley & Sons, Ltd.

  16. Chemical Biology Probes from Advanced DNA-encoded Libraries.

    PubMed

    Salamon, Hazem; Klika Škopić, Mateja; Jung, Kathrin; Bugain, Olivia; Brunschweiger, Andreas

    2016-02-19

    The identification of bioactive compounds is a crucial step toward development of probes for chemical biology studies. Screening of DNA-encoded small molecule libraries (DELs) has emerged as a validated technology to interrogate vast chemical space. DELs consist of chimeric molecules composed of a low-molecular weight compound that is conjugated to a DNA identifier tag. They are screened as pooled libraries using selection to identify "hits." Screening of DELs has identified numerous bioactive compounds. Some of these molecules were instrumental in gaining a deeper understanding of biological systems. One of the main challenges in the field is the development of synthesis methodology for DELs.

  17. The impact of mobile phone screen size on user comprehension of health information.

    PubMed

    Alghamdi, Ebtisam; Yunus, Faisel; Househ, Mowafa

    2013-01-01

    Within the field of mobile health, there is little research conducted on the impacts of mobile health technologies and applications on user comprehension of health content. In this study, we examine the difference between small, medium and large screen mobile phone that affect the user comprehension of health content. We designed an experimental study where 33 users read the contents of a health application on different mobile phone screen sizes. Each participant was timed, tracked for correctness, and gave ratings for both readability and satisfaction on each task. In addition, they were asked some questions about the contents. Results show that there was no significant impact of the screen size on user comprehension of the contents. However, it was found that participants with small screen size took longer to read the health contents.

  18. Assaying gene function by growth competition experiment.

    PubMed

    Merritt, Joshua; Edwards, Jeremy S

    2004-07-01

    High-throughput screening and analysis is one of the emerging paradigms in biotechnology. In particular, high-throughput methods are essential in the field of functional genomics because of the vast amount of data generated in recent and ongoing genome sequencing efforts. In this report we discuss integrated functional analysis methodologies which incorporate both a growth competition component and a highly parallel assay used to quantify results of the growth competition. Several applications of the two most widely used technologies in the field, i.e., transposon mutagenesis and deletion strain library growth competition, and individual applications of several developing or less widely reported technologies are presented.

  19. 78 FR 18287 - Passenger Screening Using Advanced Imaging Technology

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-26

    ... Exposure to Time-Varying Electric, Magnetic, and Electromagnetic Fields, Health Physics 74(4); 494-522... radiation safety standard of the American National Standards Institute (ANSI) \\44\\ and Health Physics... waves emissions are well below applicable safety and health standards, and are so low as to present a...

  20. Drug and bioactive molecule screening based on a bioelectrical impedance cell culture platform

    PubMed Central

    Ramasamy, Sakthivel; Bennet, Devasier; Kim, Sanghyo

    2014-01-01

    This review will present a brief discussion on the recent advancements of bioelectrical impedance cell-based biosensors, especially the electric cell-substrate impedance sensing (ECIS) system for screening of various bioactive molecules. The different technical integrations of various chip types, working principles, measurement systems, and applications for drug targeting of molecules in cells are highlighted in this paper. Screening of bioactive molecules based on electric cell-substrate impedance sensing is a trial-and-error process toward the development of therapeutically active agents for drug discovery and therapeutics. In general, bioactive molecule screening can be used to identify active molecular targets for various diseases and toxicity at the cellular level with nanoscale resolution. In the innovation and screening of new drugs or bioactive molecules, the activeness, the efficacy of the compound, and safety in biological systems are the main concerns on which determination of drug candidates is based. Further, drug discovery and screening of compounds are often performed in cell-based test systems in order to reduce costs and save time. Moreover, this system can provide more relevant results in in vivo studies, as well as high-throughput drug screening for various diseases during the early stages of drug discovery. Recently, MEMS technologies and integration with image detection techniques have been employed successfully. These new technologies and their possible ongoing transformations are addressed. Select reports are outlined, and not all the work that has been performed in the field of drug screening and development is covered. PMID:25525360

  1. ADMET biosensors: up-to-date issues and strategies.

    PubMed

    Fang, Yan; Offenhaeusser, Andrease

    2004-12-01

    This insight review introduces the new concepts, theories, technology, instruments, frontier issues, and key strategies of ADMET (absorption, distribution, metabolism, elimination, and toxicity) biosensors, from the fermi to the quantum levels. Information about ADMET, originating from one author's invention, a patented pharmacotherapy for rescuing cardio-cerebral vascular stunning and regulating vascular endothelial growth-factor signaling at the post-genomic level, can be detected by a new generation of ADMET biosensor. This is a single-cell/single-molecule field-effect transistor (FET) hybrid system, where single molecules or single cells are assembled at the FET surface in a high density array manner via complementary metal-oxide-semiconductor (CMOS)-compatible technologies. Within a given nanometer distance, ADMET-mediated oxidation-reduction (redox) potentials, electrochemistry responses, and electron transfer processes can be simultaneously and directly probed by the gates of field-effect transistor arrays. The nanometer details of the functional coupling principles and characterization technologies of DNA single-molecule/single-cell FETs, as well as the design of lab-on-a-chip instruments, are indicated. Four frontier issues and key strategies are elucidated in detail. This can lead to innovative technology for high-throughout screening of labs-on-chips to resolve the pharmaceutical industry's current bottleneck via novel, FET-based drug discovery and single-molecule/single-cell screening methods, which can bring about a pharmaceutical industry revolution in the 21st century.

  2. Microfluidics‐based 3D cell culture models: Utility in novel drug discovery and delivery research

    PubMed Central

    Gupta, Nilesh; Liu, Jeffrey R.; Patel, Brijeshkumar; Solomon, Deepak E.; Vaidya, Bhuvaneshwar

    2016-01-01

    Abstract The implementation of microfluidic devices within life sciences has furthered the possibilities of both academic and industrial applications such as rapid genome sequencing, predictive drug studies, and single cell manipulation. In contrast to the preferred two‐dimensional cell‐based screening, three‐dimensional (3D) systems have more in vivo relevance as well as ability to perform as a predictive tool for the success or failure of a drug screening campaign. 3D cell culture has shown an adaptive response to the recent advancements in microfluidic technologies which has allowed better control over spheroid sizes and subsequent drug screening studies. In this review, we highlight the most significant developments in the field of microfluidic 3D culture over the past half‐decade with a special focus on their benefits and challenges down the lane. With the newer technologies emerging, implementation of microfluidic 3D culture systems into the drug discovery pipeline is right around the bend. PMID:29313007

  3. First imagery generated by near-field real-time aperture synthesis passive millimetre wave imagers at 94 GHz and 183 GHz

    NASA Astrophysics Data System (ADS)

    Salmon, Neil A.; Mason, Ian; Wilkinson, Peter; Taylor, Chris; Scicluna, Peter

    2010-10-01

    The first passive millimetre wave (PMMW) imagery is presented from two proof-of-concept aperture synthesis demonstrators, developed to investigate the use of aperture synthesis for personnel security screening and all weather flying at 94 GHz, and satellite based earth observation at 183 GHz [1]. Emission from point noise sources and discharge tubes are used to examine the coherence on system baselines and to measure the point spread functions, making comparisons with theory. Image quality is examined using near field aperture synthesis and G-matrix calibration imaging algorithms. The radiometric sensitivity is measured using the emission from absorbers at elevated temperatures acting as extended sources and compared with theory. Capabilities of the latest Field Programmable Gate Arrays (FPGA) technologies for aperture synthesis PMMW imaging in all-weather and security screening applications are examined.

  4. Disposable Screen Printed Electrochemical Sensors: Tools for Environmental Monitoring

    PubMed Central

    Hayat, Akhtar; Marty, Jean Louis

    2014-01-01

    Screen printing technology is a widely used technique for the fabrication of electrochemical sensors. This methodology is likely to underpin the progressive drive towards miniaturized, sensitive and portable devices, and has already established its route from “lab-to-market” for a plethora of sensors. The application of these sensors for analysis of environmental samples has been the major focus of research in this field. As a consequence, this work will focus on recent important advances in the design and fabrication of disposable screen printed sensors for the electrochemical detection of environmental contaminants. Special emphasis is given on sensor fabrication methodology, operating details and performance characteristics for environmental applications. PMID:24932865

  5. A review of portal screen-film technology and five radiologists' evaluations of some existing products.

    PubMed

    Walker, M A; Steinheimer, D N; Weir, V A; Homco, L D; Green, R W; Morris, E L; Hess, M E

    1999-01-01

    Portal radiographs, radiographs made to document the accuracy of radiotherapy treatment fields, are typically of poor image contrast. Recently, a new portal film and screened-cassette system was marketed, the Kodak EC-L system, with the claim of greatly improved image contrast. This new EC-L system was tested on a canine cadaver exposed to Cobalt-60 teletherapy gamma radiation, and image quality was compared to earlier marketed Kodak portal film products. The EC-L system was found to provide portal images of improved contrast/quality.

  6. Can Technology Improve the Quality of Colonoscopy?

    PubMed

    Thirumurthi, Selvi; Ross, William A; Raju, Gottumukkala S

    2016-07-01

    In order for screening colonoscopy to be an effective tool in reducing colon cancer incidence, exams must be performed in a high-quality manner. Quality metrics have been presented by gastroenterology societies and now include higher adenoma detection rate targets than in the past. In many cases, the quality of colonoscopy can often be improved with simple low-cost interventions such as improved procedure technique, implementing split-dose bowel prep, and monitoring individuals' performances. Emerging technology has expanded our field of view and image quality during colonoscopy. We will critically review several technological advances in the context of quality metrics and discuss if technology can really improve the quality of colonoscopy.

  7. Cancer Prevention Health Services Research: An Emerging Field

    PubMed Central

    Zhao, Hui; Tektiridis, Jennifer H.; Zhang, Ning

    2013-01-01

    In October 2009, The University of Texas MD Anderson Cancer Center hosted a symposium, “Future Directions in Cancer Prevention and Control: Workforce Implications for Training, Practice, and Policy.” This article summarizes discussions and an Internet and literature review by the symposium's Health Services Infrastructure Working Group. We agree on the need for the recognition of Cancer Prevention Health Services Research (CP-HSR) as a unified research field. With advances in cancer screening and increased emphasis on preventive services under healthcare reform, there is a growing need for investigators with both cancer prevention and HSR expertise to consider the comparative effectiveness of cancer screening methods, the cost-effectiveness of early detection technologies, and the accessibility of preventive care for individuals at risk of cancer. Defining CP-HSR as a field will provide investigators with credibility and will serve to draw more researchers to the field. Increasing funding to train individuals in CP-HSR will be important to help meet the anticipated demand for investigators with this specialized multidisciplinary expertise. PMID:22311693

  8. Imaging with terahertz radiation

    NASA Astrophysics Data System (ADS)

    Chan, Wai Lam; Deibel, Jason; Mittleman, Daniel M.

    2007-08-01

    Within the last several years, the field of terahertz science and technology has changed dramatically. Many new advances in the technology for generation, manipulation, and detection of terahertz radiation have revolutionized the field. Much of this interest has been inspired by the promise of valuable new applications for terahertz imaging and sensing. Among a long list of proposed uses, one finds compelling needs such as security screening and quality control, as well as whimsical notions such as counting the almonds in a bar of chocolate. This list has grown in parallel with the development of new technologies and new paradigms for imaging and sensing. Many of these proposed applications exploit the unique capabilities of terahertz radiation to penetrate common packaging materials and provide spectroscopic information about the materials within. Several of the techniques used for terahertz imaging have been borrowed from other, more well established fields such as x-ray computed tomography and synthetic aperture radar. Others have been developed exclusively for the terahertz field, and have no analogies in other portions of the spectrum. This review provides a comprehensive description of the various techniques which have been employed for terahertz image formation, as well as discussing numerous examples which illustrate the many exciting potential uses for these emerging technologies.

  9. Single-Event Effect (SEE) Survey of Advanced Reconfigurable Field Programmable Gate Arrays: NASA Electronic Parts and Packaging (NEPP) Program Office of Safety and Mission Assurance

    NASA Technical Reports Server (NTRS)

    Allen, Gregory

    2011-01-01

    The NEPP Reconfigurable Field-Programmable Gate Array (FPGA) task has been charged to evaluate reconfigurable FPGA technologies for use in space. Under this task, the Xilinx single-event-immune, reconfigurable FPGA (SIRF) XQR5VFX130 device was evaluated for SEE. Additionally, the Altera Stratix-IV and SiliconBlue iCE65 were screened for single-event latchup (SEL).

  10. Microfluidics in microbiology: putting a magnifying glass on microbes.

    PubMed

    Siddiqui, Sanya; Tufenkji, Nathalie; Moraes, Christopher

    2016-09-12

    Microfluidic technologies enable unique studies in the field of microbiology to facilitate our understanding of microorganisms. Using miniaturized and high-throughput experimental capabilities in microfluidics, devices with controlled microenvironments can be created for microbial studies in research fields such as healthcare and green energy. In this research highlight, we describe recently developed tools for diagnostic assays, high-throughput mutant screening, and the study of human disease development as well as a future outlook on microbes for renewable energy.

  11. Interactive Whiteboards and Implications for Use in Education

    ERIC Educational Resources Information Center

    Gibson, Danita C.

    2013-01-01

    Interactive whiteboards (IWBs) have increasingly become a technology tool used in the educational field. IWBs are touch-sensitive screens that work in conjunction with a computer and a projector, and which are used to display information from a computer. As a qualitative case study, this study investigated the SMART Board-infused instructional…

  12. Screening of microbial volatile organic compounds for detection of disease in cattle: development of lab-scale method

    USDA-ARS?s Scientific Manuscript database

    The quest to find unique marker volatile organic compounds (VOCs) associated with human, livestock and wildlife diseases (Ellis et al., 2014) requires development of diagnostic non-invasive point-of-care tools and field surveillance technologies and strategies. The objective of this research was to ...

  13. Printable Electrochemical Biosensors: A Focus on Screen-Printed Electrodes and Their Application

    PubMed Central

    Yamanaka, Keiichiro; Vestergaard, Mun’delanji C.; Tamiya, Eiichi

    2016-01-01

    In this review we present electrochemical biosensor developments, focusing on screen-printed electrodes (SPEs) and their applications. In particular, we discuss how SPEs enable simple integration, and the portability needed for on-field applications. First, we briefly discuss the general concept of biosensors and quickly move on to electrochemical biosensors. Drawing from research undertaken in this area, we cover the development of electrochemical DNA biosensors in great detail. Through specific examples, we describe the fabrication and surface modification of printed electrodes for sensitive and selective detection of targeted DNA sequences, as well as integration with reverse transcription-polymerase chain reaction (RT-PCR). For a more rounded approach, we also touch on electrochemical immunosensors and enzyme-based biosensors. Last, we present some electrochemical devices specifically developed for use with SPEs, including USB-powered compact mini potentiostat. The coupling demonstrates the practical use of printable electrode technologies for application at point-of-use. Although tremendous advances have indeed been made in this area, a few challenges remain. One of the main challenges is application of these technologies for on-field analysis, which involves complicated sample matrices. PMID:27775661

  14. RPC PET: Status and perspectives

    NASA Astrophysics Data System (ADS)

    Couceiro, M.; Blanco, A.; Ferreira, Nuno C.; Ferreira Marques, R.; Fonte, P.; Lopes, L.

    2007-10-01

    The status of the resistive plate chamber (RPC)-PET technology for small animals is briefly reviewed and its sensitivity performance for human PET studied through Monte-Carlo simulations. The cost-effectiveness of these detectors and their very good timing characteristics open the possibility to build affordable Time of Flight (TOF)-PET systems with very large fields of view. Simulations suggest that the sensitivity of such systems for human whole-body screening, under reasonable assumptions, may exceed the present crystal-based PET technology by a factor up to 20.

  15. Screen-Printed Electrodes Modified with “Green” Metals for Electrochemical Stripping Analysis of Toxic Elements

    PubMed Central

    Economou, Anastasios

    2018-01-01

    This work reviews the field of screen-printed electrodes (SPEs) modified with “green” metals for electrochemical stripping analysis of toxic elements. Electrochemical stripping analysis has been established as a useful trace analysis technique offering many advantages compared to competing optical techniques. Although mercury has been the preferred electrode material for stripping analysis, the toxicity of mercury and the associated legal requirements in its use and disposal have prompted research towards the development of “green” metals as alternative electrode materials. When combined with the screen-printing technology, such environment-friendly metals can lead to disposable sensors for trace metal analysis with excellent operational characteristics. This review focuses on SPEs modified with Au, Bi, Sb, and Sn for stripping analysis of toxic elements. Different modification approaches (electroplating, bulk modification, use of metal precursors, microengineering techniques) are considered and representative applications are described. A developing related field, namely biosensing based on stripping analysis of metallic nanoprobe labels, is also briefly mentioned. PMID:29596391

  16. Screen-Printed Electrodes Modified with "Green" Metals for Electrochemical Stripping Analysis of Toxic Elements.

    PubMed

    Economou, Anastasios

    2018-03-29

    This work reviews the field of screen-printed electrodes (SPEs) modified with "green" metals for electrochemical stripping analysis of toxic elements. Electrochemical stripping analysis has been established as a useful trace analysis technique offering many advantages compared to competing optical techniques. Although mercury has been the preferred electrode material for stripping analysis, the toxicity of mercury and the associated legal requirements in its use and disposal have prompted research towards the development of "green" metals as alternative electrode materials. When combined with the screen-printing technology, such environment-friendly metals can lead to disposable sensors for trace metal analysis with excellent operational characteristics. This review focuses on SPEs modified with Au, Bi, Sb, and Sn for stripping analysis of toxic elements. Different modification approaches (electroplating, bulk modification, use of metal precursors, microengineering techniques) are considered and representative applications are described. A developing related field, namely biosensing based on stripping analysis of metallic nanoprobe labels, is also briefly mentioned.

  17. Using micropower impulse radar technology to screen for pneumothorax: an international bi-institutional study.

    PubMed

    van der Wilden, Gwendolyn M; Van der Wilden, Gwen; Albers, Christoph E; Albers, Christof; Haefeli, Pascal C; Haefeli, Peter; Zimmermann, Heinz; Zimmerman, Heinz; Exadaktylos, Aristomenis; Exadaktylos, Aris; Levy, Phillip; Birkhan, Oscar; Birkham, Oscar; Michaildou, Maria; Michailidou, Maria; Sideris, Antonios; Velmahos, George C; Velmahos, George; Alam, Hasan B; Alam, Hasan; King, David R; King, David; Fagenholz, Peter J; Fagenholz, Peter; Yeh, D Dante; Yeh, Dante; de Moya, Marc A

    2012-12-01

    Pneumothoraces (PTXs) are a common entity in thoracic trauma. Micropower impulse radar (MIR) has been able to detect PTXs in surgical patients. However, this technology has not been tested previously on trauma patients. The purpose of this study was to determine the sensitivity and specificity of MIR to detect clinically significant PTXs. We hypothesized that MIR technology can effectively screen trauma patients for clinically significant PTXs. This was a prospective observational study in Level I trauma centers in Boston, Massachusetts, and Bern, Switzerland. All trauma patients undergoing a chest computed tomographic (CT) scan were eligible for the study. Consent was obtained, and readings were performed within 30 minutes before or after the CT scan. The patients had eight lung fields tested (four on each side). The qualitative and quantitative MIR results were blinded and stored on the device. We then compared the results of the MIR to the CT scan and the need for chest tube drainage. We defined PTXs as clinically significant if they required a chest tube. Seventy-five patients were enrolled, with a mean age of 46 ± 16 years. Eighty-four percent were male. The screening test took approximately 1 minute. All but two patients had blunt chest trauma. Six true-positives, 6 false-positives, 63 true-negatives, and 0 false-negatives resulted in an overall sensitivity of 100%. MIR is an easy to use handheld technology that effectively screened patients for clinically significant PTXs, with a sensitivity and negative predictive value of 100%. MIR may be used for rapid, repeatable, and ongoing surveillance of trauma patients. Diagnostic study, level III.

  18. Terahertz endoscopic imaging for colorectal cancer detection: Current status and future perspectives

    PubMed Central

    Doradla, Pallavi; Joseph, Cecil; Giles, Robert H

    2017-01-01

    Terahertz (THz) imaging is progressing as a robust platform for myriad applications in the field of security, health, and material science. The THz regime, which comprises wavelengths spanning from microns to millimeters, is non-ionizing and has very low photon energy: Making it inherently safe for biological imaging. Colorectal cancer is one of the most common causes of death in the world, while the conventional screening and standard of care yet relies exclusively on the physician’s experience. Researchers have been working on the development of a flexible THz endoscope, as a potential tool to aid in colorectal cancer screening. This involves building a single-channel THz endoscope, and profiling the THz response from colorectal tissue, and demonstrating endogenous contrast levels between normal and diseased tissue when imaging in reflection modality. The current level of contrast provided by the prototype THz endoscopic system represents a significant step towards clinical endoscopic application of THz technology for in-vivo colorectal cancer screening. The aim of this paper is to provide a short review of the recent advances in THz endoscopic technology and cancer imaging. In particular, the potential of single-channel THz endoscopic imaging for colonic cancer screening will be highlighted. PMID:28874955

  19. Sensing Technologies for Autism Spectrum Disorder Screening and Intervention

    PubMed Central

    Cabibihan, John-John; Javed, Hifza; Aldosari, Mohammed; Frazier, Thomas W.; Elbashir, Haitham

    2016-01-01

    This paper reviews the state-of-the-art in sensing technologies that are relevant for Autism Spectrum Disorder (ASD) screening and therapy. This disorder is characterized by difficulties in social communication, social interactions, and repetitive behaviors. It is diagnosed during the first three years of life. Early and intensive interventions have been shown to improve the developmental trajectory of the affected children. The earlier the diagnosis, the sooner the intervention therapy can begin, thus, making early diagnosis an important research goal. Technological innovations have tremendous potential to assist with early diagnosis and improve intervention programs. The need for careful and methodological evaluation of such emerging technologies becomes important in order to assist not only the therapists and clinicians in their selection of suitable tools, but to also guide the developers of the technologies in improving hardware and software. In this paper, we survey the literatures on sensing technologies for ASD and we categorize them into eye trackers, movement trackers, electrodermal activity monitors, tactile sensors, vocal prosody and speech detectors, and sleep quality assessment devices. We assess their effectiveness and study their limitations. We also examine the challenges faced by this growing field that need to be addressed before these technologies can perform up to their theoretical potential. PMID:28036004

  20. Microfluidic Organ/Body-on-a-Chip Devices at the Convergence of Biology and Microengineering.

    PubMed

    Perestrelo, Ana Rubina; Águas, Ana C P; Rainer, Alberto; Forte, Giancarlo

    2015-12-10

    Recent advances in biomedical technologies are mostly related to the convergence of biology with microengineering. For instance, microfluidic devices are now commonly found in most research centers, clinics and hospitals, contributing to more accurate studies and therapies as powerful tools for drug delivery, monitoring of specific analytes, and medical diagnostics. Most remarkably, integration of cellularized constructs within microengineered platforms has enabled the recapitulation of the physiological and pathological conditions of complex tissues and organs. The so-called "organ-on-a-chip" technology, which represents a new avenue in the field of advanced in vitro models, with the potential to revolutionize current approaches to drug screening and toxicology studies. This review aims to highlight recent advances of microfluidic-based devices towards a body-on-a-chip concept, exploring their technology and broad applications in the biomedical field.

  1. Advanced human machine interaction for an image interpretation workstation

    NASA Astrophysics Data System (ADS)

    Maier, S.; Martin, M.; van de Camp, F.; Peinsipp-Byma, E.; Beyerer, J.

    2016-05-01

    In recent years, many new interaction technologies have been developed that enhance the usability of computer systems and allow for novel types of interaction. The areas of application for these technologies have mostly been in gaming and entertainment. However, in professional environments, there are especially demanding tasks that would greatly benefit from improved human machine interfaces as well as an overall improved user experience. We, therefore, envisioned and built an image-interpretation-workstation of the future, a multi-monitor workplace comprised of four screens. Each screen is dedicated to a complex software product such as a geo-information system to provide geographic context, an image annotation tool, software to generate standardized reports and a tool to aid in the identification of objects. Using self-developed systems for hand tracking, pointing gestures and head pose estimation in addition to touchscreens, face identification, and speech recognition systems we created a novel approach to this complex task. For example, head pose information is used to save the position of the mouse cursor on the currently focused screen and to restore it as soon as the same screen is focused again while hand gestures allow for intuitive manipulation of 3d objects in mid-air. While the primary focus is on the task of image interpretation, all of the technologies involved provide generic ways of efficiently interacting with a multi-screen setup and could be utilized in other fields as well. In preliminary experiments, we received promising feedback from users in the military and started to tailor the functionality to their needs

  2. Improving population health or the population itself? Health technology assessment and our genetic future.

    PubMed

    Bassett, Ken; Lee, Patricia M; Green, Carolyn J; Mitchell, Lisa; Kazanjian, Arminée

    2004-01-01

    The province of British Columbia (BC), Canada is developing its first population-wide prenatal genetic screening program, known as triple-marker screening (TMS). TMS, initiated with a simple blood test, is most commonly used to screen for fetuses with the chromosomal abnormality known as Down syndrome or neural tube disorders. Women testing TMS-positive are offered diagnostic amniocentesis and, if the diagnosis is confirmed, selective second-trimester abortion. The project described in this study was initiated to address the broad range of issues arising from this testing technology and provides an example of the new type of health technology assessment (HTA) contribution emerging (and likely to become increasing necessary) in health policy development. With the advent of prenatal genetic screening programs, would-be parents gain the promise of identifying target conditions and, hence, the option of selective abortion of affected fetuses. There is considerable awareness that these developments pose challenges in every dimension (ethical, political, economic, and clinical) of the health-care environment. In the effort to construct an appropriate prenatal screening policy, therefore, administrators have understandably sought guidance from within the field of HTA. The report authors concluded that, within the restricted path open to it, the role of government is relatively clear. It has the responsibility to maintain equal access to prenatal testing, as to any other health service. It should also require maintenance of medical standards and evaluation of program performance. At the same time, policy-makers need actively to support those individuals born with disabilities and their families.

  3. Recent developments and new applications of tandem mass spectrometry in newborn screening.

    PubMed

    Rinaldo, Piero; Tortorelli, Silvia; Matern, Dietrich

    2004-08-01

    To summarize recent developments in the field of newborn screening related to the use of tandem mass spectrometry as an analytic platform. Novel inborn errors of metabolism with informative amino acid and/or acylcarnitine profiles have been characterized, increasing the complexity of the differential diagnosis of abnormal results. In addition, methods have been developed for the analysis in dried blood spots of steroids and lysosomal enzymes. Previously unrecognized genotype/phenotype correlations have been found among cohorts of patients whose conditions were diagnosed by screening rather than clinically. Several government entities and professional organizations have issued position statements on newborn screening, and worldwide outcome studies continue to underscore the clinical and financial benefits of expanded newborn screening. Although it is done inconsistently, newborn screening in the United States is undergoing a rapid expansion driven by the introduction of tandem mass spectrometry in at least 34 state programs. This technology is also used to detect disease markers beyond acylcarnitines and amino acids, as both primary and second-tier tests. In addition to analytic improvements, there is a trend toward the development of joint programs not limited to contiguous geographic areas, often based upon public-private partnerships. This review will summarize several new developments in the field that have occurred since early 2003 and will mention others likely to occur in the near future.

  4. Population and High-Risk Group Screening for Glaucoma: The Los Angeles Latino Eye Study

    PubMed Central

    Francis, Brian A.; Vigen, Cheryl; Lai, Mei-Ying; Winarko, Jonathan; Nguyen, Betsy; Azen, Stanley

    2011-01-01

    Purpose. To evaluate the ability of various screening tests, both individually and in combination, to detect glaucoma in the general Latino population and high-risk subgroups. Methods. The Los Angeles Latino Eye Study is a population-based study of eye disease in Latinos 40 years of age and older. Participants (n = 6082) underwent Humphrey visual field testing (HVF), frequency doubling technology (FDT) perimetry, measurement of intraocular pressure (IOP) and central corneal thickness (CCT), and independent assessment of optic nerve vertical cup disc (C/D) ratio. Screening parameters were evaluated for three definitions of glaucoma based on optic disc, visual field, and a combination of both. Analyses were also conducted for high-risk subgroups (family history of glaucoma, diabetes mellitus, and age ≥65 years). Sensitivity, specificity, and receiver operating characteristic curves were calculated for those continuous parameters independently associated with glaucoma. Classification and regression tree (CART) analysis was used to develop a multivariate algorithm for glaucoma screening. Results. Preset cutoffs for screening parameters yielded a generally poor balance of sensitivity and specificity (sensitivity/specificity for IOP ≥21 mm Hg and C/D ≥0.8 was 0.24/0.97 and 0.60/0.98, respectively). Assessment of high-risk subgroups did not improve the sensitivity/specificity of individual screening parameters. A CART analysis using multiple screening parameters—C/D, HVF, and IOP—substantially improved the balance of sensitivity and specificity (sensitivity/specificity 0.92/0.92). Conclusions. No single screening parameter is useful for glaucoma screening. However, a combination of vertical C/D ratio, HVF, and IOP provides the best balance of sensitivity/specificity and is likely to provide the highest yield in glaucoma screening programs. PMID:21245400

  5. Development of technical means for directional hydraulic fracturing with shearing loading of borehole walls

    NASA Astrophysics Data System (ADS)

    Rybalkin, LA; Patutin, AV; Patutin, DV

    2018-03-01

    During the process of mineral deposits’ mining one of the most important conditions for safe and economically profitable work of a mining enterprise is obtaining timely information on the stress state of the developed massif. One of the most common methods of remote study of the geomechanical state of the rock massif is hydraulic fracturing of the formation. Directional hydraulic fracturing is a type of the method employed to form cracks across production wells. This technology was most widely used in the gas industry to extract gas from shale formations. In mining, this technology is used to set up filtration screens, to integrate degassing, to soften the hard roof of coal seams. Possible practical appliance is the expansion of the application field of this technology to intensify the production of viscous oil, to leach non-ferrous metals, to create in the rock massif anti-filtration screens for various purposes, as well as to measure stresses acting along the wells.

  6. Economic Benefit of Coal Utilization/Conversion at Air Force Bases: Screening Study

    DTIC Science & Technology

    1989-08-01

    fire-tLbe) boilers that are small enough to be shipped by rail. The field-erected units are larger, water- tube boilers. The pulverized coal-fired and...circulating FBC boilers considered are field-erected, water- tube boilers. Pollution control technology costs were considered to a limited extent. All...Coal/H 0 mix (S/MBtu) = 3.00 OPTIONS Cal/oil mix (S/MBtu) 3.50 Soot blower multiplier = 0.0 Tube bank mod multiplier = 1.0 Primary fuel is 1 Bottom ash

  7. Role of stranded gas in increasing global gas supplies

    USGS Publications Warehouse

    Attanasi, E.D.; Freeman, P.A.

    2013-01-01

    This report synthesizes the findings of three regional studies in order to evaluate, at the global scale, the contribution that stranded gas resources can make to global natural gas supplies. Stranded gas, as defined for this study, is natural gas in discovered conventional gas and oil fields that is currently not commercially producible for either physical or economic reasons. The regional studies evaluated the cost of bringing the large volumes of undeveloped gas in stranded gas fields to selected markets. In particular, stranded gas fields of selected Atlantic Basin countries, north Africa, Russia, and central Asia are screened to determine whether the volumes are sufficient to meet Europe’s increasing demand for gas imports. Stranded gas fields in Russia, central Asia, Southeast Asia, and Australia are also screened to estimate development, production, and transport costs and corresponding gas volumes that could be supplied to Asian markets in China, India, Japan, and South Korea. The data and cost analysis presented here suggest that for the European market and the markets examined in Asia, the development of stranded gas provides a way to meet projected gas import demands for the 2020-to-2040 period. Although this is a reconnaissance-type appraisal, it is based on volumes of gas that are associated with individual identified fields. Individual field data were carefully examined. Some fields were not evaluated because current technology was insufficient or it appeared the gas was likely to be held off the export market. Most of the evaluated stranded gas can be produced and delivered to markets at costs comparable to historical prices. Moreover, the associated volumes of gas are sufficient to provide an interim supply while additional technologies are developed to unlock gas diffused in shale and hydrates or while countries transition to making a greater use of renewable energy sources.

  8. ENVIRONMENTAL TECHNOLOGY VERIFICATION: JOINT (NSF-EPA) VERIFICATION STATEMENT AND REPORT: BROME AGRI SALES, LTD., MAXIMIZER SEPARATOR, MODEL MAX 1016 - 03/01/WQPC-SWP

    EPA Science Inventory

    Verification testing of the Brome Agri Sales Ltd. Maximizer Separator, Model MAX 1016 (Maximizer) was conducted at the Lake Wheeler Road Field Laboratory Swine Educational Unit in Raleigh, North Carolina. The Maximizer is an inclined screen solids separator that can be used to s...

  9. Electric-field-driven switching of individual magnetic skyrmions

    NASA Astrophysics Data System (ADS)

    Hsu, Pin-Jui; Kubetzka, André; Finco, Aurore; Romming, Niklas; von Bergmann, Kirsten; Wiesendanger, Roland

    2017-02-01

    Controlling magnetism with electric fields is a key challenge to develop future energy-efficient devices. The present magnetic information technology is mainly based on writing processes requiring either local magnetic fields or spin torques, but it has also been demonstrated that magnetic properties can be altered on the application of electric fields. This has been ascribed to changes in magnetocrystalline anisotropy caused by spin-dependent screening and modifications of the band structure, changes in atom positions or differences in hybridization with an adjacent oxide layer. However, the switching between states related by time reversal, for example magnetization up and down as used in the present technology, is not straightforward because the electric field does not break time-reversal symmetry. Several workarounds have been applied to toggle between bistable magnetic states with electric fields, including changes of material composition as a result of electric fields. Here we demonstrate that local electric fields can be used to switch reversibly between a magnetic skyrmion and the ferromagnetic state. These two states are topologically inequivalent, and we find that the direction of the electric field directly determines the final state. This observation establishes the possibility to combine electric-field writing with the recently envisaged skyrmion racetrack-type memories.

  10. No. 348-Joint SOGC-CCMG Guideline: Update on Prenatal Screening for Fetal Aneuploidy, Fetal Anomalies, and Adverse Pregnancy Outcomes.

    PubMed

    Audibert, Francois; De Bie, Isabelle; Johnson, Jo-Ann; Okun, Nanette; Wilson, R Douglas; Armour, Christine; Chitayat, David; Kim, Raymond

    2017-09-01

    To review the available prenatal screening options in light of the recent technical advances and to provide an update of previous guidelines in the field of prenatal screening. Health care providers involved in prenatal screening, including general practitioners, obstetricians, midwives, maternal fetal medicine specialists, geneticists, and radiologists. All pregnant women receiving counselling and providing informed consent for prenatal screening. Published literature was retrieved through searches of Medline, PubMed, and the Cochrane Library in and prior to March 2016 using an appropriate controlled vocabulary (prenatal diagnosis, amniocentesis, chorionic villi sampling, non-invasive prenatal screening) and key words (prenatal screening, prenatal genetic counselling). Results were restricted to systematic reviews, randomized control trials/controlled clinical trials, and observational studies written in English and published from January 1985 to May 2016. Searches were updated on a regular basis and incorporated in the guideline. Grey (unpublished) literature was identified through searching the websites of health technology assessment and health technology-related agencies, clinical practice guideline collections, clinical trial registries, and national and international medical speciality societies. Evidence will be reviewed 5 years after publication to determine whether all or part of the guideline should be updated. However, if important new evidence is published prior to the 5-year cycle, the review process may be accelerated for a more rapid update of some recommendations. Copyright © 2017 The Society of Obstetricians and Gynaecologists of Canada/La Société des obstétriciens et gynécologues du Canada. Published by Elsevier Inc. All rights reserved.

  11. Novel drug discovery for Chagas disease.

    PubMed

    Moraes, Carolina B; Franco, Caio H

    2016-01-01

    Chagas disease is a chronic infection associated with long-term morbidity. Increased funding and advocacy for drug discovery for neglected diseases have prompted the introduction of several important technological advances, and Chagas disease is among the neglected conditions that has mostly benefited from technological developments. A number of screening campaigns, and the development of new and improved in vitro and in vivo assays, has led to advances in the field of drug discovery. This review highlights the major advances in Chagas disease drug screening, and how these are being used not only to discover novel chemical entities and drug candidates, but also increase our knowledge about the disease and the parasite. Different methodologies used for compound screening and prioritization are discussed, as well as novel techniques for the investigation of these targets. The molecular mechanism of action is also discussed. Technological advances have been executed with scientific rigour for the development of new in vitro cell-based assays and in vivo animal models, to bring about novel and better drugs for Chagas disease, as well as to increase our understanding of what are the necessary properties for a compound to be successful in the clinic. The gained knowledge, combined with new exciting approaches toward target deconvolution, will help identifying new targets for Chagas disease chemotherapy in the future.

  12. Microfluidic Organ/Body-on-a-Chip Devices at the Convergence of Biology and Microengineering

    PubMed Central

    Perestrelo, Ana Rubina; Águas, Ana C. P.; Rainer, Alberto; Forte, Giancarlo

    2015-01-01

    Recent advances in biomedical technologies are mostly related to the convergence of biology with microengineering. For instance, microfluidic devices are now commonly found in most research centers, clinics and hospitals, contributing to more accurate studies and therapies as powerful tools for drug delivery, monitoring of specific analytes, and medical diagnostics. Most remarkably, integration of cellularized constructs within microengineered platforms has enabled the recapitulation of the physiological and pathological conditions of complex tissues and organs. The so-called “organ-on-a-chip” technology, which represents a new avenue in the field of advanced in vitro models, with the potential to revolutionize current approaches to drug screening and toxicology studies. This review aims to highlight recent advances of microfluidic-based devices towards a body-on-a-chip concept, exploring their technology and broad applications in the biomedical field. PMID:26690442

  13. Technical literature review.

    PubMed

    Nußbeck, Gunnar; Gök, Murat

    2013-01-01

    This review gives a comprehensive overview on the technical perspective of personal health monitoring. It is designed to build a mutual basis for the project partners of the PHM-Ethics project. A literature search was conducted to screen pertinent literature databases for relevant publications. All review papers that were retrieved were analyzed. The increasing number of publications that are published per year shows that the field of personal health monitoring is of growing interest in the research community. Most publications deal with telemonitoring, thus forming the core technology of personal health monitoring. Measured parameters, fields of application, participants and stakeholders are described. Moreover an outlook on information and communication technology that foster the integration possibilities of personal health monitoring into decision making and remote monitoring of individual people's health is provided. The removal of the technological barriers opens new perspectives in health and health care delivery using home monitoring applications.

  14. Ultrasensitive Single Fluorescence-Labeled Probe-Mediated Single Universal Primer-Multiplex-Droplet Digital Polymerase Chain Reaction for High-Throughput Genetically Modified Organism Screening.

    PubMed

    Niu, Chenqi; Xu, Yuancong; Zhang, Chao; Zhu, Pengyu; Huang, Kunlun; Luo, Yunbo; Xu, Wentao

    2018-05-01

    As genetically modified (GM) technology develops and genetically modified organisms (GMOs) become more available, GMOs face increasing regulations and pressure to adhere to strict labeling guidelines. A singleplex detection method cannot perform the high-throughput analysis necessary for optimal GMO detection. Combining the advantages of multiplex detection and droplet digital polymerase chain reaction (ddPCR), a single universal primer-multiplex-ddPCR (SUP-M-ddPCR) strategy was proposed for accurate broad-spectrum screening and quantification. The SUP increases efficiency of the primers in PCR and plays an important role in establishing a high-throughput, multiplex detection method. Emerging ddPCR technology has been used for accurate quantification of nucleic acid molecules without a standard curve. Using maize as a reference point, four heterologous sequences ( 35S, NOS, NPTII, and PAT) were selected to evaluate the feasibility and applicability of this strategy. Surprisingly, these four genes cover more than 93% of the transgenic maize lines and serve as preliminary screening sequences. All screening probes were labeled with FAM fluorescence, which allows the signals from the samples with GMO content and those without to be easily differentiated. This fiveplex screening method is a new development in GMO screening. Utilizing an optimal amplification assay, the specificity, limit of detection (LOD), and limit of quantitation (LOQ) were validated. The LOD and LOQ of this GMO screening method were 0.1% and 0.01%, respectively, with a relative standard deviation (RSD) < 25%. This method could serve as an important tool for the detection of GM maize from different processed, commercially available products. Further, this screening method could be applied to other fields that require reliable and sensitive detection of DNA targets.

  15. High-throughput screening approaches and combinatorial development of biomaterials using microfluidics.

    PubMed

    Barata, David; van Blitterswijk, Clemens; Habibovic, Pamela

    2016-04-01

    From the first microfluidic devices used for analysis of single metabolic by-products to highly complex multicompartmental co-culture organ-on-chip platforms, efforts of many multidisciplinary teams around the world have been invested in overcoming the limitations of conventional research methods in the biomedical field. Close spatial and temporal control over fluids and physical parameters, integration of sensors for direct read-out as well as the possibility to increase throughput of screening through parallelization, multiplexing and automation are some of the advantages of microfluidic over conventional, 2D tissue culture in vitro systems. Moreover, small volumes and relatively small cell numbers used in experimental set-ups involving microfluidics, can potentially decrease research cost. On the other hand, these small volumes and numbers of cells also mean that many of the conventional molecular biology or biochemistry assays cannot be directly applied to experiments that are performed in microfluidic platforms. Development of different types of assays and evidence that such assays are indeed a suitable alternative to conventional ones is a step that needs to be taken in order to have microfluidics-based platforms fully adopted in biomedical research. In this review, rather than providing a comprehensive overview of the literature on microfluidics, we aim to discuss developments in the field of microfluidics that can aid advancement of biomedical research, with emphasis on the field of biomaterials. Three important topics will be discussed, being: screening, in particular high-throughput and combinatorial screening; mimicking of natural microenvironment ranging from 3D hydrogel-based cellular niches to organ-on-chip devices; and production of biomaterials with closely controlled properties. While important technical aspects of various platforms will be discussed, the focus is mainly on their applications, including the state-of-the-art, future perspectives and challenges. Microfluidics, being a technology characterized by the engineered manipulation of fluids at the submillimeter scale, offers some interesting tools that can advance biomedical research and development. Screening platforms based on microfluidic technologies that allow high-throughput and combinatorial screening may lead to breakthrough discoveries not only in basic research but also relevant to clinical application. This is further strengthened by the fact that reliability of such screens may improve, since microfluidic systems allow close mimicking of physiological conditions. Finally, microfluidic systems are also very promising as micro factories of a new generation of natural or synthetic biomaterials and constructs, with finely controlled properties. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  16. Current impact of gene technology on healthcare. A map of economic assessments.

    PubMed

    Rogowski, Wolf

    2007-02-01

    It has been claimed that gene technology will induce revolutionary changes in healthcare. This paper investigates how and to what extent these changes have been economically assessed. A generic framework was developed to distinguish between methodologically similar evaluations of healthcare technology. Methodological issues and the current state of economic evidence concerning human DNA technology were extracted from publications within these groups of evaluations. Economic evaluations of "healthcare consisting of gene technology" were identified primarily for in vitro diagnostics for hereditary disease and others for pharmacogenetics and molecular pathology. "Healthcare enabled by gene technology" is far more encompassing and includes, e.g., biotechnology drugs for which various health economic evaluations can be found. Yet here, the impact of gene technology intertwines with the impact of other technologies and is therefore hardly susceptible to evaluation. The fields of evaluation may be classified best according to the two dimensions "purpose" and "stage of development". Current evaluations cover screening, diagnostic and treatment technologies in investigational, new and established stages. Apart from prenatal screening, healthcare consisting of gene technology was cost saving only for genotype tests replacing continuous phenotype tests and for one pharmacogenetic test. Conclusive evidence of favourable cost-effectiveness ratios is available only for few conditions. Hypotheses about the impact of gene technology on healthcare must be explicit about the definition of "genetic" medicine. A general statement regarding healthcare enabled by gene technology is not possible. Based on current evidence, an era of healthcare consisting of gene technology built on widespread predictive testing is not desirable from a health economic viewpoint.

  17. Genome Editing Redefines Precision Medicine in the Cardiovascular Field

    PubMed Central

    Lahm, Harald; Dreßen, Martina; Lange, Rüdiger; Wu, Sean M.; Krane, Markus

    2018-01-01

    Genome editing is a powerful tool to study the function of specific genes and proteins important for development or disease. Recent technologies, especially CRISPR/Cas9 which is characterized by convenient handling and high precision, revolutionized the field of genome editing. Such tools have enormous potential for basic science as well as for regenerative medicine. Nevertheless, there are still several hurdles that have to be overcome, but patient-tailored therapies, termed precision medicine, seem to be within reach. In this review, we focus on the achievements and limitations of genome editing in the cardiovascular field. We explore different areas of cardiac research and highlight the most important developments: (1) the potential of genome editing in human pluripotent stem cells in basic research for disease modelling, drug screening, or reprogramming approaches and (2) the potential and remaining challenges of genome editing for regenerative therapies. Finally, we discuss social and ethical implications of these new technologies. PMID:29731778

  18. Alternative Solvents/Technologies for Paint Stripping: Phase 1.

    DTIC Science & Technology

    1994-03-01

    processes . Three phases of study are defined: Phase I, identify alternate solvents/strippers and screen them; Phase II, field test solvent/ strippers...Section Title Page 1 Metal Refinishing Process - Immersion Method ............... 8 2 Phase Summary Chart ........................ 12 3 The...of the following: (a) nontoxic chemical formulations, (b) new process development, and (c) new coating reformulations. This program consists of three

  19. Performance characterization of a combined material identification and screening algorithm

    NASA Astrophysics Data System (ADS)

    Green, Robert L.; Hargreaves, Michael D.; Gardner, Craig M.

    2013-05-01

    Portable analytical devices based on a gamut of technologies (Infrared, Raman, X-Ray Fluorescence, Mass Spectrometry, etc.) are now widely available. These tools have seen increasing adoption for field-based assessment by diverse users including military, emergency response, and law enforcement. Frequently, end-users of portable devices are non-scientists who rely on embedded software and the associated algorithms to convert collected data into actionable information. Two classes of problems commonly encountered in field applications are identification and screening. Identification algorithms are designed to scour a library of known materials and determine whether the unknown measurement is consistent with a stored response (or combination of stored responses). Such algorithms can be used to identify a material from many thousands of possible candidates. Screening algorithms evaluate whether at least a subset of features in an unknown measurement correspond to one or more specific substances of interest and are typically configured to detect from a small list potential target analytes. Thus, screening algorithms are much less broadly applicable than identification algorithms; however, they typically provide higher detection rates which makes them attractive for specific applications such as chemical warfare agent or narcotics detection. This paper will present an overview and performance characterization of a combined identification/screening algorithm that has recently been developed. It will be shown that the combined algorithm provides enhanced detection capability more typical of screening algorithms while maintaining a broad identification capability. Additionally, we will highlight how this approach can enable users to incorporate situational awareness during a response.

  20. Screen printing technology applied to silicon solar cell fabrication

    NASA Technical Reports Server (NTRS)

    Thornhill, J. W.; Sipperly, W. E.

    1980-01-01

    The process for producing space qualified solar cells in both the conventional and wraparound configuration using screen printing techniques was investigated. Process modifications were chosen that could be easily automated or mechanized. Work was accomplished to optimize the tradeoffs associated with gridline spacing, gridline definition and junction depth. An extensive search for possible front contact metallization was completed. The back surface field structures along with the screen printed back contacts were optimized to produce open circuit voltages of at least an average of 600 millivolts. After all intended modifications on the process sequence were accomplished, the cells were exhaustively tested. Electrical tests at AMO and 28 C were made before and after boiling water immersion, thermal shock, and storage under conditions of high temperature and high humidity.

  1. Advances in fragment-based drug discovery platforms.

    PubMed

    Orita, Masaya; Warizaya, Masaichi; Amano, Yasushi; Ohno, Kazuki; Niimi, Tatsuya

    2009-11-01

    Fragment-based drug discovery (FBDD) has been established as a powerful alternative and complement to traditional high-throughput screening techniques for identifying drug leads. At present, this technique is widely used among academic groups as well as small biotech and large pharmaceutical companies. In recent years, > 10 new compounds developed with FBDD have entered clinical development, and more and more attention in the drug discovery field is being focused on this technique. Under the FBDD approach, a fragment library of relatively small compounds (molecular mass = 100 - 300 Da) is screened by various methods and the identified fragment hits which normally weakly bind to the target are used as starting points to generate more potent drug leads. Because FBDD is still a relatively new drug discovery technology, further developments and optimizations in screening platforms and fragment exploitation can be expected. This review summarizes recent advances in FBDD platforms and discusses the factors important for the successful application of this technique. Under the FBDD approach, both identifying the starting fragment hit to be developed and generating the drug lead from that starting fragment hit are important. Integration of various techniques, such as computational technology, X-ray crystallography, NMR, surface plasmon resonance, isothermal titration calorimetry, mass spectrometry and high-concentration screening, must be applied in a situation-appropriate manner.

  2. Facilitating mental health screening of war-torn populations using mobile applications.

    PubMed

    Hashemi, Bahar; Ali, Sara; Awaad, Rania; Soudi, Laila; Housel, Lawrence; Sosebee, Stephen J

    2017-01-01

    War-torn populations are often hard to screen for mental health disorders. Classical data collection approaches, such as paper-based, online, or SMS-operated, are either infeasible or lack accuracy due to a variety of challenges associated with dynamics and consequences of war. In this paper, we introduce a novel approach for accurate and fast screening using free open-source software, Open Data Kit (ODK) mobile application. This approach was developed by the Palestine Children's Relief Fund (PCRF) to assess the mental health symptoms of 986 Palestinian children (age 6-18) in the aftermath of Israel's Operation Protective Edge (OPE) in 2014. The organization developed assessment questionnaires and trained local field workers on the use of the mobile application, and on recruiting and interviewing war victims. War-affected children were found to suffer from several alarming symptoms associated with post-traumatic stress disorder (PTSD), depression, and somatic symptoms. Children with highest number of psychological symptoms were referred for further evaluation and treatment. The use of ODK mobile technologies facilitated efficient screening of affected children in war zones. The offline data collection capability was crucial for handling the difficult conditions associated with war-torn areas, enabling timely intervention for urgent cases. Further applications of the novel mobile technology are to be explored.

  3. Macromolecular Crystallization with Microfluidic Free-Interface Diffusion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Segelke, B

    2005-02-24

    Fluidigm released the Topaz 1.96 and 4.96 crystallization chips in the fall of 2004. Topaz 1.96 and 4.96 are the latest evolution of Fluidigm's microfluidics crystallization technologies that enable ultra low volume rapid screening for macromolecular crystallization. Topaz 1.96 and 4.96 are similar to each other but represent a major redesign of the Topaz system and have of substantially improved ease of automation and ease of use, improved efficiency and even further reduced amount of material needed. With the release of the new Topaz system, Fluidigm continues to set the standard in low volume crystallization screening which is having anmore » increasing impact in the field of structural genomics, and structural biology more generally. In to the future we are likely to see further optimization and increased utility of the Topaz crystallization system, but we are also likely to see further innovation and the emergence of competing technologies.« less

  4. 3D printing in neurosurgery: A systematic review

    PubMed Central

    Randazzo, Michael; Pisapia, Jared M.; Singh, Nickpreet; Thawani, Jayesh P.

    2016-01-01

    Background: The recent expansion of three-dimensional (3D) printing technology into the field of neurosurgery has prompted a widespread investigation of its utility. In this article, we review the current body of literature describing rapid prototyping techniques with applications to the practice of neurosurgery. Methods: An extensive and systematic search of the Compendex, Scopus, and PubMed medical databases was conducted using keywords relating to 3D printing and neurosurgery. Results were manually screened for relevance to applications within the field. Results: Of the search results, 36 articles were identified and included in this review. The articles spanned the various subspecialties of the field including cerebrovascular, neuro-oncologic, spinal, functional, and endoscopic neurosurgery. Conclusions: We conclude that 3D printing techniques are practical and anatomically accurate methods of producing patient-specific models for surgical planning, simulation and training, tissue-engineered implants, and secondary devices. Expansion of this technology may, therefore, contribute to advancing the neurosurgical field from several standpoints. PMID:27920940

  5. Lessons from high-throughput protein crystallization screening: 10 years of practical experience

    PubMed Central

    JR, Luft; EH, Snell; GT, DeTitta

    2011-01-01

    Introduction X-ray crystallography provides the majority of our structural biological knowledge at a molecular level and in terms of pharmaceutical design is a valuable tool to accelerate discovery. It is the premier technique in the field, but its usefulness is significantly limited by the need to grow well-diffracting crystals. It is for this reason that high-throughput crystallization has become a key technology that has matured over the past 10 years through the field of structural genomics. Areas covered The authors describe their experiences in high-throughput crystallization screening in the context of structural genomics and the general biomedical community. They focus on the lessons learnt from the operation of a high-throughput crystallization screening laboratory, which to date has screened over 12,500 biological macromolecules. They also describe the approaches taken to maximize the success while minimizing the effort. Through this, the authors hope that the reader will gain an insight into the efficient design of a laboratory and protocols to accomplish high-throughput crystallization on a single-, multiuser-laboratory or industrial scale. Expert Opinion High-throughput crystallization screening is readily available but, despite the power of the crystallographic technique, getting crystals is still not a solved problem. High-throughput approaches can help when used skillfully; however, they still require human input in the detailed analysis and interpretation of results to be more successful. PMID:22646073

  6. Evaluation of a New Shirt-Based Electrocardiogram Device for Cardiac Screening in Soccer Players: Comparative Study With Treadmill Ergospirometry.

    PubMed

    Fabregat-Andres, Oscar; Munoz-Macho, Adolfo; Adell-Beltran, Guillermo; Ibanez-Catala, Xavier; Macia, Agustin; Facila, Lorenzo

    2014-08-01

    Prevention of cardiac events during competitive sports is fundamental. New technologies with remote monitoring systems integrated into clothing could facilitate the screening of heart disease. Our aim was to evaluate the feasibility of Nuubo system during a field stress test performed by soccer players, comparing results with treadmill ergospirometry as test reference. Nineteen male professional soccer players (19.2 ± 1.6 years) were studied. Wireless electrocardiographic monitoring during a Yo-Yo intermittent recovery test level 1 in soccer field and subsequent analysis of arrhythmias were firstly performed. Subsequently, in a period no longer than 4 weeks, each player underwent cardiopulmonary exercise testing in hospital. During Yo-Yo test, electrocardiogram (ECG) signal was interpretable in 16 players (84.2%). In the other three players, ECG artifacts did not allow a proper analysis. Estimation of maximum oxygen consumption was comparable between two exercise tests (VO 2 max 53.3 ± 2.4 vs. 53.7 ± 3.0 mL/kg/min for Yo-Yo test and ergometry respectively; intra-class correlation coefficient 0.84 (0.63 - 0.93), P < 0.001). No arrhythmias were detected in any player during both tests. The use of Nuubo's technology allows an accurate single-lead electrocardiographic recording and estimation of reliable performance variables during exercise testing in field, and provides a new perspective to cardiac remote monitoring in collective sports.

  7. High-density functional-RNA arrays as a versatile platform for studying RNA-based interactions.

    PubMed

    Phillips, Jack O; Butt, Louise E; Henderson, Charlotte A; Devonshire, Martin; Healy, Jess; Conway, Stuart J; Locker, Nicolas; Pickford, Andrew R; Vincent, Helen A; Callaghan, Anastasia J

    2018-05-28

    We are just beginning to unravel the myriad of interactions in which non-coding RNAs participate. The intricate RNA interactome is the foundation of many biological processes, including bacterial virulence and human disease, and represents unexploited resources for the development of potential therapeutic interventions. However, identifying specific associations of a given RNA from the multitude of possible binding partners within the cell requires robust high-throughput systems for their rapid screening. Here, we present the first demonstration of functional-RNA arrays as a novel platform technology designed for the study of such interactions using immobilized, active RNAs. We have generated high-density RNA arrays by an innovative method involving surface-capture of in vitro transcribed RNAs. This approach has significant advantages over existing technologies, particularly in its versatility in regards to binding partner character. Indeed, proof-of-principle application of RNA arrays to both RNA-small molecule and RNA-RNA pairings is demonstrated, highlighting their potential as a platform technology for mapping RNA-based networks and for pharmaceutical screening. Furthermore, the simplicity of the method supports greater user-accessibility over currently available technologies. We anticipate that functional-RNA arrays will find broad utility in the expanding field of RNA characterization.

  8. Implications of newborn screening for nurses.

    PubMed

    DeLuca, Jane; Zanni, Karen L; Bonhomme, Natasha; Kemper, Alex R

    2013-03-01

    Newborn screening has dramatically decreased the morbidity and mortality associated with a wide range of heritable conditions. Continuing advances in screening technology and improvements in the effectiveness of treatment are driving the rapid expansion of newborn screening programs. In this article, we review issues in newborn screening care and opportunities for nurses and nursing faculty to provide education and conduct research to improve the impact of newborn screening. This article provides (a) an overview of current newborn screening activities, including how conditions are added to newborn screening panels and how implementation occurs at state and national levels; (b) a description of current controversies and ethical considerations; (c) a description of the roles of nurses in the newborn screening process; (d) suggestions for nursing education and research; and (e) a summary of expected future developments in newborn screening, including genome sequencing. Nurses are uniquely well suited to address the educational needs and future research in newborn screening because of the role that nurses play in the provision of direct clinical care and in population-based healthcare delivery. Newborn screening is a public health approach to the identification of rare but treatable conditions in early infancy. In the United States, as in other industrialized countries, newborn screening is rapidly expanding. Nurses, nurse educators, and nurse researchers are positioned to contribute to the field of newborn screening by assuring programs are implemented safely and effectively, by facilitating education of the nursing work force, and by developing and contributing to research programs in newborn screening. © 2013 Sigma Theta Tau International.

  9. Refreshable Braille displays using EAP actuators

    NASA Astrophysics Data System (ADS)

    Bar-Cohen, Yoseph

    2010-04-01

    Refreshable Braille can help visually impaired persons benefit from the growing advances in computer technology. The development of such displays in a full screen form is a great challenge due to the need to pack many actuators in small area without interferences. In recent years, various displays using actuators such as piezoelectric stacks have become available in commercial form but most of them are limited to one line Braille code. Researchers in the field of electroactive polymers (EAP) investigated methods of using these materials to form full screen displays. This manuscript reviews the state of the art of producing refreshable Braille displays using EAP-based actuators.

  10. Refreshable Braille Displays Using EAP Actuators

    NASA Technical Reports Server (NTRS)

    Bar-Cohen, Yoseph

    2010-01-01

    Refreshable Braille can help visually impaired persons benefit from the growing advances in computer technology. The development of such displays in a full screen form is a great challenge due to the need to pack many actuators in small area without interferences. In recent years, various displays using actuators such as piezoelectric stacks have become available in commercial form but most of them are limited to one line Braille code. Researchers in the field of electroactive polymers (EAP) investigated methods of using these materials to form full screen displays. This manuscript reviews the state of the art of producing refreshable Braille displays using EAP-based actuators..

  11. Establishing Substantial Equivalence: Metabolomics

    NASA Astrophysics Data System (ADS)

    Beale, Michael H.; Ward, Jane L.; Baker, John M.

    Modern ‘metabolomic’ methods allow us to compare levels of many structurally diverse compounds in an automated fashion across a large number of samples. This technology is ideally suited to screening of populations of plants, including trials where the aim is the determination of unintended effects introduced by GM. A number of metabolomic methods have been devised for the determination of substantial equivalence. We have developed a methodology, using [1H]-NMR fingerprinting, for metabolomic screening of plants and have applied it to the study of substantial equivalence of field-grown GM wheat. We describe here the principles and detail of that protocol as applied to the analysis of flour generated from field plots of wheat. Particular emphasis is given to the downstream data processing and comparison of spectra by multivariate analysis, from which conclusions regarding metabolome changes due to the GM can be assessed against the background of natural variation due to environment.

  12. The New Realm of 3-D Vision

    NASA Technical Reports Server (NTRS)

    2002-01-01

    Dimension Technologies Inc., developed a line of 2-D/3-D Liquid Crystal Display (LCD) screens, including a 15-inch model priced at consumer levels. DTI's family of flat panel LCD displays, called the Virtual Window(TM), provide real-time 3-D images without the use of glasses, head trackers, helmets, or other viewing aids. Most of the company initial 3-D display research was funded through NASA's Small Business Innovation Research (SBIR) program. The images on DTI's displays appear to leap off the screen and hang in space. The display accepts input from computers or stereo video sources, and can be switched from 3-D to full-resolution 2-D viewing with the push of a button. The Virtual Window displays have applications in data visualization, medicine, architecture, business, real estate, entertainment, and other research, design, military, and consumer applications. Displays are currently used for computer games, protein analysis, and surgical imaging. The technology greatly benefits the medical field, as surgical simulators are helping to increase the skills of surgical residents. Virtual Window(TM) is a trademark of Dimension Technologies Inc.

  13. 76 FR 45645 - 10-Day Notice of Proposed Information Collection: Technology Security/Clearance Plans, Screening...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-29

    ...: Technology Security/Clearance Plans, Screening Records, and Non-Disclosure Agreements ACTION: Notice of... Information Collection: Technology Security/ Clearance Plans, Screening Records, and Non-Disclosure Agreements...: None. Respondents: Business and Nonprofit Organizations, Foreign Governments. Estimated Number of...

  14. TECHNOLOGIES FORM MONITORING AND ...

    EPA Pesticide Factsheets

    A demonstration of technologies for determining the presence of dioxin and dioxin-like compounds in soil and sediment was conducted under EPA's Superfund Innovative Technology Evaluation Program in Saginaw, Michigan in April 2004. This report describes the evaluation of Wako Pure Chemical Industries's Dioxin ELISA Kit. The kit is an immunoassay technique that reports toxicity equivalents (TEQ) of dioxin/furans. The sample units are in pg/g 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) equivalents (EQ). The technology results were compared to high resolution mass spectrometry (HRMS) TEQ results generated using EPA Method 1613B.The Wako results were biased both positively and negatively relative to HRMS results. The technologys estimated method detection limit was 83-201 pg/g 2,3,7,8-TCDD EQ, but this should be considered a rough estimate. Results from this demonstration suggest that the Wako kit could be an effective screening tool for determining sample results above and below 20 pg/g TEQ, and even more effective as a screen for samples above and below 50 pg/g TEQ, particularly considering the cost to analyze the 209 demonstration samples was significantly less than that of the reference laboratory ($150,294 vs. $213,580), and all samples were analyzed on-site in 9 days (in comparison to the reference laboratory which took 8 months). The objective of this program is to promote the acceptance and use of innovative field technologies by providing well-documented per

  15. Catalogue of satellite photography of the active volcanoes of the world

    NASA Technical Reports Server (NTRS)

    Heiken, G.

    1976-01-01

    A catalogue is presented of active volcanoes as viewed from Earth-orbiting satellites. The listing was prepared of photographs, which have been screened for quality, selected from the earth resources technology satellite (ERTS) and Skylab, Apollo and Gemini spacecraft. There is photography of nearly every active volcano in the world; the photographs are particularly useful for regional studies of volcanic fields.

  16. Flow Regime Transition in Inner Grooved Minichannel Cold Plates for Cooling Hybrid Electric Power Electronics

    DTIC Science & Technology

    2013-01-01

    reentrant cavities) Corrugated or fluted tubes Screens Inner grooved tubes ( microfin tubes ) Fins Electrohydrodynamic field effect 3.1 Convective... microfin geometries, including 3-D geometries, but most commercial vendors continue to manufacture seamless tubes (46). Figure 6a shows the...enhancement technologies are compiled in table 4. Table 4. Comparison of leading refrigeration tube performance (42). Metric Microfin Tube Twisted

  17. The current revolution in newborn screening: new technology, old controversies.

    PubMed

    Tarini, Beth A

    2007-08-01

    Newborn screening has provided a model of a successful public health screening program for the past 40 years. However, the history of newborn screening is not without controversy. Many of these controversies have been rekindled with the introduction of tandem mass spectrometry, a technology that has greatly increased our ability to detect potential disease in asymptomatic newborns. This review highlights the challenges raised by this and future technological advances as we strive to maintain the success of newborn screening in the 21st century.

  18. Establishing MALDI-TOF as Versatile Drug Discovery Readout to Dissect the PTP1B Enzymatic Reaction.

    PubMed

    Winter, Martin; Bretschneider, Tom; Kleiner, Carola; Ries, Robert; Hehn, Jörg P; Redemann, Norbert; Luippold, Andreas H; Bischoff, Daniel; Büttner, Frank H

    2018-07-01

    Label-free, mass spectrometric (MS) detection is an emerging technology in the field of drug discovery. Unbiased deciphering of enzymatic reactions is a proficient advantage over conventional label-based readouts suffering from compound interference and intricate generation of tailored signal mediators. Significant evolvements of matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) MS, as well as associated liquid handling instrumentation, triggered extensive efforts in the drug discovery community to integrate the comprehensive MS readout into the high-throughput screening (HTS) portfolio. Providing speed, sensitivity, and accuracy comparable to those of conventional, label-based readouts, combined with merits of MS-based technologies, such as label-free parallelized measurement of multiple physiological components, emphasizes the advantages of MALDI-TOF for HTS approaches. Here we describe the assay development for the identification of protein tyrosine phosphatase 1B (PTP1B) inhibitors. In the context of this precious drug target, MALDI-TOF was integrated into the HTS environment and cross-compared with the well-established AlphaScreen technology. We demonstrate robust and accurate IC 50 determination with high accordance to data generated by AlphaScreen. Additionally, a tailored MALDI-TOF assay was developed to monitor compound-dependent, irreversible modification of the active cysteine of PTP1B. Overall, the presented data proves the promising perspective for the integration of MALDI-TOF into drug discovery campaigns.

  19. Saliva-Based Biosensors: Noninvasive Monitoring Tool for Clinical Diagnostics

    PubMed Central

    Malon, Radha S. P.; Balakrishnan, Malarvili; Córcoles, Emma P.

    2014-01-01

    Saliva is increasingly recognised as an attractive diagnostic fluid. The presence of various disease signalling salivary biomarkers that accurately reflect normal and disease states in humans and the sampling benefits compared to blood sampling are some of the reasons for this recognition. This explains the burgeoning research field in assay developments and technological advancements for the detection of various salivary biomarkers to improve clinical diagnosis, management, and treatment. This paper reviews the significance of salivary biomarkers for clinical diagnosis and therapeutic applications, with focus on the technologies and biosensing platforms that have been reported for screening these biomarkers. PMID:25276835

  20. Saliva-based biosensors: noninvasive monitoring tool for clinical diagnostics.

    PubMed

    Malon, Radha S P; Sadir, Sahba; Balakrishnan, Malarvili; Córcoles, Emma P

    2014-01-01

    Saliva is increasingly recognised as an attractive diagnostic fluid. The presence of various disease signalling salivary biomarkers that accurately reflect normal and disease states in humans and the sampling benefits compared to blood sampling are some of the reasons for this recognition. This explains the burgeoning research field in assay developments and technological advancements for the detection of various salivary biomarkers to improve clinical diagnosis, management, and treatment. This paper reviews the significance of salivary biomarkers for clinical diagnosis and therapeutic applications, with focus on the technologies and biosensing platforms that have been reported for screening these biomarkers.

  1. FCS Technology Investigation Overview

    NASA Technical Reports Server (NTRS)

    Budinger, James; Gilbert, Tricia

    2007-01-01

    This working paper provides an overview of the Future Communication Study (FCS) technology investigation progress. It includes a description of the methodology applied to technology evaluation; evaluation criteria; and technology screening (down select) results. A comparison of screening results with other similar technology screening activities is provided. Additional information included in this working paper is a description of in-depth studies (including characterization of the L-band aeronautical channel; L-band deployment cost assessment; and performance assessments of candidate technologies in the applicable aeronautical channel) that have been conducted to support technology evaluations. The paper concludes with a description on-going activities leading to conclusion of the technology investigation and the development of technology recommendations.

  2. What is the impact of disease prevalence upon health technology assessment?

    PubMed

    Rotily, Michel; Roze, Stéphane

    2013-12-01

    As national budgets for health care will remain under stress for the foreseeable future, health technology assessment (HTA) aimed at offering guidance to policy-making will have an increasing role to play in optimizing resources. The emergence of new treatment paradigms and health technologies, and the prevalence studies which determine when a disease is a current or future burden for patients and the community are in the roots of the HTA process. Analysing studies on screening test strategies and health care policy, this paper revisits two key concepts in epidemiology, prevalence and incidence, in order to show their major impact upon HTA. Utilization of the predictive values of screening tests that include prevalence in their calculations, and analysing all options for screening strategies are necessary in HTA. Cost-effectiveness analyses and statistical models should include potential externalities, especially the impact of prevention and treatment on infectious disease prevalence. Beyond estimates of cost-effectiveness ratios, decision makers also need to know by how much their annual health care budget is likely to increase or decrease in the years following the emergence of new technologies: hence the importance of incidence- or prevalence-based economic evaluations. As new paradigms are occurring, especially in the field of oncology, with treatments targeted to 'small' groups of patients identified through genetic testing, prevalence data are strongly needed. Precise estimates of disease prevalence, in general populations as well as in risk or targeted groups, will therefore be necessary to improve HTA process. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Assay development and screening of a serine/threonine kinase in an on-chip mode using caliper nanofluidics technology.

    PubMed

    Perrin, Dominique; Frémaux, Christèle; Scheer, Alexander

    2006-06-01

    Kinases are key targets for drug discovery. In the field of screening in general and especially in the kinase area, because of considerations of efficiency and cost, radioactivity-based assays tend to be replaced by alternative, mostly fluorescence-based, assays. Today, the limiting factor is rarely the number of data points that can be obtained but rather the quality of the data, enzyme availability, and cost. In this article, the authors describe the development of an assay for a kinase screen based on the electrophoretic separation of fluorescent product and substrate using a Caliper-based nanofluidics environment in on-chip incubation mode. The authors present the results of screening a focused set of 32,000 compounds together with confirmation data obtained in a filtration assay. In addition, they have made a small-scale comparison between the on-chip and off-chip nanofluidics screening modes. In their hands, the screen in on-chip mode is characterized by high precision most likely due to the absence of liquid pipetting; an excellent confirmation rate (62%) in an independent assay format, namely, filtration; and good sensitivity. This study led to the identification of 4 novel chemical series of inhibitors.

  4. Evaluation of a New Shirt-Based Electrocardiogram Device for Cardiac Screening in Soccer Players: Comparative Study With Treadmill Ergospirometry

    PubMed Central

    Fabregat-Andres, Oscar; Munoz-Macho, Adolfo; Adell-Beltran, Guillermo; Ibanez-Catala, Xavier; Macia, Agustin; Facila, Lorenzo

    2014-01-01

    Background Prevention of cardiac events during competitive sports is fundamental. New technologies with remote monitoring systems integrated into clothing could facilitate the screening of heart disease. Our aim was to evaluate the feasibility of Nuubo system during a field stress test performed by soccer players, comparing results with treadmill ergospirometry as test reference. Methods Nineteen male professional soccer players (19.2 ± 1.6 years) were studied. Wireless electrocardiographic monitoring during a Yo-Yo intermittent recovery test level 1 in soccer field and subsequent analysis of arrhythmias were firstly performed. Subsequently, in a period no longer than 4 weeks, each player underwent cardiopulmonary exercise testing in hospital. Results During Yo-Yo test, electrocardiogram (ECG) signal was interpretable in 16 players (84.2%). In the other three players, ECG artifacts did not allow a proper analysis. Estimation of maximum oxygen consumption was comparable between two exercise tests (VO2 max 53.3 ± 2.4 vs. 53.7 ± 3.0 mL/kg/min for Yo-Yo test and ergometry respectively; intra-class correlation coefficient 0.84 (0.63 - 0.93), P < 0.001). No arrhythmias were detected in any player during both tests. Conclusions The use of Nuubo’s technology allows an accurate single-lead electrocardiographic recording and estimation of reliable performance variables during exercise testing in field, and provides a new perspective to cardiac remote monitoring in collective sports. PMID:28348705

  5. Multispectral THz-VIS passive imaging system for hidden threats visualization

    NASA Astrophysics Data System (ADS)

    Kowalski, Marcin; Palka, Norbert; Szustakowski, Mieczyslaw

    2013-10-01

    Terahertz imaging, is the latest entry into the crowded field of imaging technologies. Many applications are emerging for the relatively new technology. THz radiation penetrates deep into nonpolar and nonmetallic materials such as paper, plastic, clothes, wood, and ceramics that are usually opaque at optical wavelengths. The T-rays have large potential in the field of hidden objects detection because it is not harmful to humans. The main difficulty in the THz imaging systems is low image quality thus it is justified to combine THz images with the high-resolution images from a visible camera. An imaging system is usually composed of various subsystems. Many of the imaging systems use imaging devices working in various spectral ranges. Our goal is to build a system harmless to humans for screening and detection of hidden objects using a THz and VIS cameras.

  6. Acceptability and validity of older driver screening with the DrivingHealth Inventory.

    PubMed

    Edwards, Jerri D; Leonard, Kathleen M; Lunsman, Melissa; Dodson, Joan; Bradley, Stacy; Myers, Charlsie A; Hubble, Bridgette

    2008-05-01

    Research has indicated that technology can be effectively used to identify high-risk older drivers. However, adaptation of such technology has been limited. Researchers debate whether older drivers represent a safety problem as well as whether they should be screened for driving fitness. The present study examined how drivers feel regarding technological screening and mandatory state testing. The validity and acceptability of a new technological screening battery for identifying high-risk drivers, the DrivingHealth Inventory (DHI), was also evaluated. In a sample of 258 Alabama drivers aged 18-87, older drivers performed significantly worse than younger drivers on sensory, cognitive, and physical subtests of the DHI, and older drivers with a crash history performed worse than older drivers without crashes. Regardless of age, 90% of participants supported states requiring screening for older drivers' license renewal. The majority of the participants (72%) supported use of technological screening batteries such as the DHI as a driver screening tool. Considering the acceptability and potential efficacy of the DHI, it may be a useful tool in evaluating driving fitness among older adults.

  7. Engineered heart tissues and induced pluripotent stem cells: Macro- and microstructures for disease modeling, drug screening, and translational studies.

    PubMed

    Tzatzalos, Evangeline; Abilez, Oscar J; Shukla, Praveen; Wu, Joseph C

    2016-01-15

    Engineered heart tissue has emerged as a personalized platform for drug screening. With the advent of induced pluripotent stem cell (iPSC) technology, patient-specific stem cells can be developed and expanded into an indefinite source of cells. Subsequent developments in cardiovascular biology have led to efficient differentiation of cardiomyocytes, the force-producing cells of the heart. iPSC-derived cardiomyocytes (iPSC-CMs) have provided potentially limitless quantities of well-characterized, healthy, and disease-specific CMs, which in turn has enabled and driven the generation and scale-up of human physiological and disease-relevant engineered heart tissues. The combined technologies of engineered heart tissue and iPSC-CMs are being used to study diseases and to test drugs, and in the process, have advanced the field of cardiovascular tissue engineering into the field of precision medicine. In this review, we will discuss current developments in engineered heart tissue, including iPSC-CMs as a novel cell source. We examine new research directions that have improved the function of engineered heart tissue by using mechanical or electrical conditioning or the incorporation of non-cardiomyocyte stromal cells. Finally, we discuss how engineered heart tissue can evolve into a powerful tool for therapeutic drug testing. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Evaluation of carrier collection probability in bifacial interdigitated-back-contact crystalline silicon solar cells by the internal quantum efficiency mapping method

    NASA Astrophysics Data System (ADS)

    Tachibana, Tomihisa; Tanahashi, Katsuto; Mochizuki, Toshimitsu; Shirasawa, Katsuhiko; Takato, Hidetaka

    2018-04-01

    Bifacial interdigitated-back-contact (IBC) silicon solar cells with a high bifaciality of 0.91 were fabricated. Screen printing and firing technology were used to reduce the production cost. For the first time, the relationship between the rear side structure and carrier collection probability was evaluated using internal quantum efficiency (IQE) mapping. The measurement results showed that the screen-printed electrode and back surface field (BSF) area led to low IQE. The low carrier collection probability by BSF area can be explained by electrical shading effects. Thus, it is clear that the IQE mapping system is useful to evaluate the IBC cell.

  9. The evolving role of new imaging methods in breast screening.

    PubMed

    Houssami, Nehmat; Ciatto, Stefano

    2011-09-01

    The potential to avert breast cancer deaths through screening means that efforts continue to identify methods which may enhance early detection. While the role of most new imaging technologies remains in adjunct screening or in the work-up of mammography-detected abnormalities, some of the new breast imaging tests (such as MRI) have roles in screening groups of women defined by increased cancer risk. This paper highlights the evidence and the current role of new breast imaging technologies in screening, focusing on those that have broader application in population screening, including digital mammography, breast ultrasound in women with dense breasts, and computer-aided detection. It highlights that evidence on new imaging in screening comes mostly from non-randomised studies that have quantified test detection capability as adjunct to mammography, or have compared measures of screening performance for new technologies with that of conventional mammography. Two RCTs have provided high-quality evidence on the equivalence of digital and conventional mammography and on outcomes of screen-reading complemented by CAD. Many of these imaging technologies enhance cancer detection but also increase recall and false positives in screening. Copyright © 2011 Elsevier Inc. All rights reserved.

  10. 2013 R&D 100 Award: 'SHIELD' protects NIF optics from harmful pulses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chou, Jason

    In the past, it took as long as 12 hours to manually screen 48 critical checkpoints at the National Ignition Facility (NIF) for harmful laser pulses. The screening equipment had to be moved from point to point throughout a facility the size of three football fields. Now with a new technology, called Laser SHIELD (Screening at High-throughput to Identify Energetic Laser Distortion), and with the push of a button, the screening can be done in less than one second. Proper screening of pulses is critical for the operation of high-energy lasers to ensure that the laser does not exceed safemore » operating conditions for optics. The energetic beams of light are so powerful that, when left uncontrolled, they can shatter the extremely valuable glass inside the laser. If a harmful pulse is found, immediate adjustments can be made in order to protect the optics for the facility. Laser SHIELD is a custom-designed high-throughput screening system built from low-cost and commercially available components found in the telecommunications industry. Its all-fiber design makes it amenable to the unique needs of high-energy laser facilities, including routing to intricate pick-off locations, immunity to electromagnetic interference and low-loss transport (up to several kilometers). The technology offers several important benefits for NIF. First, the facility is able to fire more shots in less time-an efficiency that saves the facility millions of dollars each year. Second, high-energy lasers are more flexible to wavelength changes requested by target physicists. Third, by identifying harmful pulses before they damage the laser's optics, the facility potentially saves hundreds of thousands of dollars in maintenance costs each year.« less

  11. 2013 R&D 100 Award: 'SHIELD' protects NIF optics from harmful pulses

    ScienceCinema

    Chou, Jason

    2018-02-13

    In the past, it took as long as 12 hours to manually screen 48 critical checkpoints at the National Ignition Facility (NIF) for harmful laser pulses. The screening equipment had to be moved from point to point throughout a facility the size of three football fields. Now with a new technology, called Laser SHIELD (Screening at High-throughput to Identify Energetic Laser Distortion), and with the push of a button, the screening can be done in less than one second. Proper screening of pulses is critical for the operation of high-energy lasers to ensure that the laser does not exceed safe operating conditions for optics. The energetic beams of light are so powerful that, when left uncontrolled, they can shatter the extremely valuable glass inside the laser. If a harmful pulse is found, immediate adjustments can be made in order to protect the optics for the facility. Laser SHIELD is a custom-designed high-throughput screening system built from low-cost and commercially available components found in the telecommunications industry. Its all-fiber design makes it amenable to the unique needs of high-energy laser facilities, including routing to intricate pick-off locations, immunity to electromagnetic interference and low-loss transport (up to several kilometers). The technology offers several important benefits for NIF. First, the facility is able to fire more shots in less time-an efficiency that saves the facility millions of dollars each year. Second, high-energy lasers are more flexible to wavelength changes requested by target physicists. Third, by identifying harmful pulses before they damage the laser's optics, the facility potentially saves hundreds of thousands of dollars in maintenance costs each year.

  12. The Roles of General and Technology-Related Parenting in Managing Youth Screen Time

    PubMed Central

    Sanders, Wesley; Parent, Justin; Forehand, Rex; Lafko, Nicole

    2015-01-01

    The purpose of this study was to examine the associations of two types of parenting practices -- general adaptive parenting and technology-related strategies – with youth screen time. It was hypothesized that technology-related parenting focused on behavioral control would relate directly to screen time and serve to link general parenting to screen time. Participants were 615 parents drawn from three community samples of families with children across three development stages: young childhood (3 – 7 yrs.; n = 210), middle childhood (8 – 12 yrs.; n = 200), and adolescents (13 – 17 yrs.; n = 205). Using structural equation modeling, general adaptive parenting was not related to child screen time but was positively related to technology-related parenting strategies for all three samples. For the young and, to some extent middle, childhood samples, but not for the adolescent sample, general adaptive parenting was positively linked to youth screen time through technology-related parenting strategies. PMID:26751759

  13. Efficiency evaluation for remediating paddy soil contaminated with cadmium and arsenic using water management, variety screening and foliage dressing technologies.

    PubMed

    Liao, Guojian; Wu, Qianhua; Feng, Renwei; Guo, Junkang; Wang, Ruigang; Xu, Yingming; Ding, Yongzhen; Fan, Zhilian; Mo, Liangyu

    2016-04-01

    Paddy soils in many regions of China have been seriously polluted by multiple heavy metals or metalloids, such as arsenic (As), cadmium (Cd) and lead (Pb). In order to ensure the safety of food and take full advantage of the limited farmland resources of China, exploring an effective technology to repair contaminated soils is urgent and necessary. In this study, three technologies were employed, including variety screening, water management and foliage dressing, to assess their abilities to reduce the accumulation of Cd and As in the grains of different rice varieties, and meanwhile monitor the related yields. The results of variety screening under insufficient field drying condition showed that the As and Cd contents in the grains of only four varieties [Fengliangyouxiang 1 (P6), Zhongzheyou 8 (P7), Guangliangyou 1128 (P10), Y-liangyou 696 (P11)] did not exceed their individual national standard. P6 gained a relatively high grain yield but accumulated less As and Cd in the grains despite of the relatively high As and Cd concentrations in the rhizosphere soil. However, long-playing field drying in water management trial significantly increased Cd but decreased As content in the grains of all tested three varieties including P6, suggesting an important role of water supply in controlling the accumulation of grain As and Cd. Selenium (Se) showed a stronger ability than silicon (Si) to reduce As and Cd accumulation in the grains of Fengliangyou 4 (P2) and Teyou 524 (P13), and keep the yields. The results of this study suggest that combined application of water management and foliage dressing may be an efficient way to control As and Cd accumulation in the grains of paddy rice exposing to As- and Cd-contaminated soils. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. shRNA target prediction informed by comprehensive enquiry (SPICE): a supporting system for high-throughput screening of shRNA library.

    PubMed

    Kamatuka, Kenta; Hattori, Masahiro; Sugiyama, Tomoyasu

    2016-12-01

    RNA interference (RNAi) screening is extensively used in the field of reverse genetics. RNAi libraries constructed using random oligonucleotides have made this technology affordable. However, the new methodology requires exploration of the RNAi target gene information after screening because the RNAi library includes non-natural sequences that are not found in genes. Here, we developed a web-based tool to support RNAi screening. The system performs short hairpin RNA (shRNA) target prediction that is informed by comprehensive enquiry (SPICE). SPICE automates several tasks that are laborious but indispensable to evaluate the shRNAs obtained by RNAi screening. SPICE has four main functions: (i) sequence identification of shRNA in the input sequence (the sequence might be obtained by sequencing clones in the RNAi library), (ii) searching the target genes in the database, (iii) demonstrating biological information obtained from the database, and (iv) preparation of search result files that can be utilized in a local personal computer (PC). Using this system, we demonstrated that genes targeted by random oligonucleotide-derived shRNAs were not different from those targeted by organism-specific shRNA. The system facilitates RNAi screening, which requires sequence analysis after screening. The SPICE web application is available at http://www.spice.sugysun.org/.

  15. Biosensing with Paper-Based Miniaturized Printed Electrodes-A Modern Trend.

    PubMed

    Silveira, Célia M; Monteiro, Tiago; Almeida, Maria Gabriela

    2016-09-28

    From the bench-mark work on microfluidics from the Whitesides's group in 2007, paper technology has experienced significant growth, particularly regarding applications in biomedical research and clinical diagnostics. Besides the structural properties supporting microfluidics, other advantageous features of paper materials, including their versatility, disposability and low cost, show off the great potential for the development of advanced and eco-friendly analytical tools. Consequently, paper was quickly employed in the field of electrochemical sensors, being an ideal material for producing custom, tailored and miniaturized devices. Stencil-, inkjet-, or screen-printing are the preferential techniques for electrode manufacturing. Not surprisingly, we witnessed a rapid increase in the number of publications on paper based screen-printed sensors at the turn of the past decade. Among the sensing strategies, various biosensors, coupling electrochemical detectors with biomolecules, have been proposed. This work provides a critical review and a discussion on the future progress of paper technology in the context of miniaturized printed electrochemical biosensors.

  16. Biosensing with Paper-Based Miniaturized Printed Electrodes–A Modern Trend

    PubMed Central

    Silveira, Célia M.; Monteiro, Tiago; Almeida, Maria Gabriela

    2016-01-01

    From the bench-mark work on microfluidics from the Whitesides’s group in 2007, paper technology has experienced significant growth, particularly regarding applications in biomedical research and clinical diagnostics. Besides the structural properties supporting microfluidics, other advantageous features of paper materials, including their versatility, disposability and low cost, show off the great potential for the development of advanced and eco-friendly analytical tools. Consequently, paper was quickly employed in the field of electrochemical sensors, being an ideal material for producing custom, tailored and miniaturized devices. Stencil-, inkjet-, or screen-printing are the preferential techniques for electrode manufacturing. Not surprisingly, we witnessed a rapid increase in the number of publications on paper based screen-printed sensors at the turn of the past decade. Among the sensing strategies, various biosensors, coupling electrochemical detectors with biomolecules, have been proposed. This work provides a critical review and a discussion on the future progress of paper technology in the context of miniaturized printed electrochemical biosensors. PMID:27690119

  17. Thermal effusivity: a promising imaging biomarker to predict radiation-induced skin injuries.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chu, J. C. H.; Templeton, A.; Yao, R.

    An effective screening technology is needed to triage individuals at the time of radiation incidents involving a large population. Three-dimensional thermal tomography is a relatively new development in active thermal imaging technology that produces cross-sectional images based on the subject's ability to transfer heat thermal effusivity at the voxel level. This noninvasive imaging modality has been used successfully in nondestructive examination of complex materials; also it has been shown to predict the severity of radiation-induced skin injuries several days before the manifestation of severe moist desquamations or blister formation symptoms in mice at 40 Gy. If these results are confirmedmore » at lower dose levels in human subjects, a thermal tomography imaging device may be an ideal screening tool in radiation emergencies. This imaging method is non-invasive, relatively simple, easily adaptable for field use, and when properly deployed, it will enhance public emergency preparedness for incidents involving unexpected radiation exposure.« less

  18. In situ remediation of DNAPL compounds in low permeability media fate/transport, in situ control technologies, and risk reduction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-08-01

    In this project, in situ remediation technologies are being tested and evaluated for both source control and mass removal of dense, non-aqueous phase liquid (DNAPL) compounds in low permeability media (LPM). This effort is focused on chlorinated solvents (e.g., trichloroethylene and perchloroethylene) in the vadose and saturated zones of low permeability, massive deposits, and stratified deposits with inter-bedded clay lenses. The project includes technology evaluation and screening analyses and field-scale testing at both clean and contaminated sites in the US and Canada. Throughout this project, activities have been directed at understanding the processes that influence DNPAL compound migration and treatmentmore » in LPM and to assessing the operation and performance of the remediation technologies developed and tested. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database.« less

  19. cDNA Microarray Screening in Food Safety

    PubMed Central

    ROY, SASHWATI; SEN, CHANDAN K

    2009-01-01

    The cDNA microarray technology and related bioinformatics tools presents a wide range of novel application opportunities. The technology may be productively applied to address food safety. In this mini-review article, we present an update highlighting the late breaking discoveries that demonstrate the vitality of cDNA microarray technology as a tool to analyze food safety with reference to microbial pathogens and genetically modified foods. In order to bring the microarray technology to mainstream food safety, it is important to develop robust user-friendly tools that may be applied in a field setting. In addition, there needs to be a standardized process for regulatory agencies to interpret and act upon microarray-based data. The cDNA microarray approach is an emergent technology in diagnostics. Its values lie in being able to provide complimentary molecular insight when employed in addition to traditional tests for food safety, as part of a more comprehensive battery of tests. PMID:16466843

  20. Population-based mammography screening: comparison of screen-film and full-field digital mammography with soft-copy reading--Oslo I study.

    PubMed

    Skaane, Per; Young, Kari; Skjennald, Arnulf

    2003-12-01

    To compare screen-film and full-field digital mammography with soft-copy reading in a population-based screening program. Full-field digital and screen-film mammography were performed in 3,683 women aged 50-69 years. Two standard views of each breast were acquired with each modality. Images underwent independent double reading with use of a five-point rating scale for probability of cancer. Recall rates and positive predictive values were calculated. Cancer detection rates determined with both modalities were compared by using the McNemar test for paired proportions. Retrospective side-by-side analysis for conspicuity of cancers was performed by an external independent radiologist group with experience in both modalities. In 3,683 cases, 31 cancers were detected. Screen-film mammography depicted 28 (0.76%) malignancies, and full-field digital mammography depicted 23 (0.62%) malignancies. The difference between cancer detection rates was not significant (P =.23). The recall rate for full-field digital mammography (4.6%; 168 of 3,683 cases) was slightly higher than that for screen-film mammography (3.5%; 128 of 3,683 cases). The positive predictive value based on needle biopsy results was 46% for screen-film mammography and 39% for full-field digital mammography. Side-by-side image comparison for cancer conspicuity led to classification of 19 cancers as equal for probability of malignancy, six cancers as slightly better demonstrated at screen-film mammography, and six cancers as slightly better demonstrated at full-field digital mammography. There was no statistically significant difference in cancer detection rate between screen-film and full-field digital mammography. Cancer conspicuity was equal with both modalities. Full-field digital mammography with soft-copy reading is comparable to screen-film mammography in population-based screening.

  1. Simulation assessment of the direct‐push permeameter for characterizing vertical variations in hydraulic conductivity

    USGS Publications Warehouse

    Liu, Gaisheng; Bohling, Geoffrey C.; Butler, James J.

    2008-01-01

    The direct‐push permeameter (DPP) is a tool for the in situ characterization of hydraulic conductivity (K) in shallow, unconsolidated formations. This device, which consists of a short screened section with a pair of pressure transducers near the screen, is advanced into the subsurface with direct‐push technology. K is determined through a series of injection tests conducted between advancements. Recent field work by Butler et al. (2007) has shown that the DPP holds great potential for describing vertical variations in K at an unprecedented level of detail, accuracy and speed. In this paper, the fundamental efficacy of the DPP is evaluated through a series of numerical simulations. These simulations demonstrate that the DPP can provide accurate K information under conditions commonly faced in the field. A single DPP test provides an effective K for the domain immediately surrounding the interval between the injection screen and the most distant pressure transducer. Features that are thinner than that interval can be quantified by reducing the vertical distance between successive tests and analyzing the data from all tests simultaneously. A particular advantage of the DPP is that, unlike most other single borehole techniques, a low‐K skin or a clogged screen has a minimal impact on the K estimate. In addition, the requirement that only steady‐shape conditions be attained allows for a dramatic reduction in the time required for each injection test.

  2. Lung cancer disparities and African-Americans.

    PubMed

    Sin, Mo-Kyung

    2017-07-01

    African-Americans, as historically disadvantaged minorities, have more advanced stages of cancer when diagnosed, lower survival rates, and lower rates of accessing timely care than do Caucasians. Lung cancer incidence and mortality, in particular, are high among African-Americans. The U.S. Preventive Services Task Force recently released an evidence-based lung cancer screening technology called low-dose computerized tomography. High-risk African-Americans might benefit greatly from such screening but not many are aware of this technology. Public health nurses can play a key role in increasing awareness of the technology among African-American communities and encouraging qualified African-Americans to obtain screening. This study discusses issues with lung cancer and smoking among African-Americans, a recently released evidence-based lung cancer screening technology, and implications for public health nurses to enhance uptake of the new screening technology among high-risk African-Americans. © 2017 Wiley Periodicals, Inc.

  3. Case study: technology initiative led to advanced lead optimization screening processes at Bristol-Myers Squibb, 2004-2009.

    PubMed

    Zhang, Litao; Cvijic, Mary Ellen; Lippy, Jonathan; Myslik, James; Brenner, Stephen L; Binnie, Alastair; Houston, John G

    2012-07-01

    In this paper, we review the key solutions that enabled evolution of the lead optimization screening support process at Bristol-Myers Squibb (BMS) between 2004 and 2009. During this time, technology infrastructure investment and scientific expertise integration laid the foundations to build and tailor lead optimization screening support models across all therapeutic groups at BMS. Together, harnessing advanced screening technology platforms and expanding panel screening strategy led to a paradigm shift at BMS in supporting lead optimization screening capability. Parallel SAR and structure liability relationship (SLR) screening approaches were first and broadly introduced to empower more-rapid and -informed decisions about chemical synthesis strategy and to broaden options for identifying high-quality drug candidates during lead optimization. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. Smart material screening machines using smart materials and controls

    NASA Astrophysics Data System (ADS)

    Allaei, Daryoush; Corradi, Gary; Waigand, Al

    2002-07-01

    The objective of this product is to address the specific need for improvements in the efficiency and effectiveness in physical separation technologies in the screening areas. Currently, the mining industry uses approximately 33 billion kW-hr per year, costing 1.65 billion dollars at 0.05 cents per kW-hr, of electrical energy for physical separations. Even though screening and size separations are not the single most energy intensive process in the mining industry, they are often the major bottleneck in the whole process. Improvements to this area offer tremendous potential in both energy savings and production improvements. Additionally, the vibrating screens used in the mining processing plants are the most costly areas from maintenance and worker health and safety point of views. The goal of this product is to reduce energy use in the screening and total processing areas. This goal is accomplished by developing an innovative screening machine based on smart materials and smart actuators, namely smart screen that uses advanced sensory system to continuously monitor the screening process and make appropriate adjustments to improve production. The theory behind the development of Smart Screen technology is based on two key technologies, namely smart actuators and smart Energy Flow ControlT (EFCT) strategies, developed initially for military applications. Smart Screen technology controls the flow of vibration energy and confines it to the screen rather than shaking much of the mass that makes up the conventional vibratory screening machine. Consequently, Smart Screens eliminates and downsizes many of the structural components associated with conventional vibratory screening machines. As a result, the surface area of the screen increases for a given envelope. This increase in usable screening surface area extends the life of the screens, reduces required maintenance by reducing the frequency of screen change-outs and improves throughput or productivity.

  5. Touch-screen technology usage in toddlers.

    PubMed

    Ahearne, Caroline; Dilworth, Sinead; Rollings, Rachel; Livingstone, Vicki; Murray, Deirdre

    2016-02-01

    To establish the prevalence and patterns of use of touch-screen technologies in the toddler population. Parental questionnaires were completed for children aged 12 months to 3 years examining access to touch-screen devices and ability to perform common forms of interaction with touch-screen technologies. The 82 questionnaires completed on typically developing children revealed 71% of toddlers had access to touch-screen devices for a median of 15 min (IQR: 9.375-26.25) per day. By parental report, 24 months was the median age of ability to swipe (IQR: 19.5-30.5), unlock (IQR: 20.5-31.5) and active looking for touch-screen features (IQR: 22-30.5), while 25 months (IQR: 21-31.25) was the median age of ability to identify and use specific touch-screen features. Overall, 32.8% of toddlers could perform all four skills. From 2 years of age toddlers have the ability to interact purposefully with touch-screen devices and demonstrate a variety of common skills required to utilise touch-screen technology. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  6. High-Throughput Silencing Using the CRISPR-Cas9 System: A Review of the Benefits and Challenges.

    PubMed

    Wade, Mark

    2015-09-01

    The clustered regularly interspaced short palindromic repeats (CRISPR)/Cas system has been seized upon with a fervor enjoyed previously by small interfering RNA (siRNA) and short hairpin RNA (shRNA) technologies and has enormous potential for high-throughput functional genomics studies. The decision to use this approach must be balanced with respect to adoption of existing platforms versus awaiting the development of more "mature" next-generation systems. Here, experience from siRNA and shRNA screening plays an important role, as issues such as targeting efficiency, pooling strategies, and off-target effects with those technologies are already framing debates in the CRISPR field. CRISPR/Cas can be exploited not only to knockout genes but also to up- or down-regulate gene transcription-in some cases in a multiplex fashion. This provides a powerful tool for studying the interaction among multiple signaling cascades in the same genetic background. Furthermore, the documented success of CRISPR/Cas-mediated gene correction (or the corollary, introduction of disease-specific mutations) provides proof of concept for the rapid generation of isogenic cell lines for high-throughput screening. In this review, the advantages and limitations of CRISPR/Cas are discussed and current and future applications are highlighted. It is envisaged that complementarities between CRISPR, siRNA, and shRNA will ensure that all three technologies remain critical to the success of future functional genomics projects. © 2015 Society for Laboratory Automation and Screening.

  7. Large scale meta-analysis of fragment-based screening campaigns: privileged fragments and complementary technologies.

    PubMed

    Kutchukian, Peter S; Wassermann, Anne Mai; Lindvall, Mika K; Wright, S Kirk; Ottl, Johannes; Jacob, Jaison; Scheufler, Clemens; Marzinzik, Andreas; Brooijmans, Natasja; Glick, Meir

    2015-06-01

    A first step in fragment-based drug discovery (FBDD) often entails a fragment-based screen (FBS) to identify fragment "hits." However, the integration of conflicting results from orthogonal screens remains a challenge. Here we present a meta-analysis of 35 fragment-based campaigns at Novartis, which employed a generic 1400-fragment library against diverse target families using various biophysical and biochemical techniques. By statistically interrogating the multidimensional FBS data, we sought to investigate three questions: (1) What makes a fragment amenable for FBS? (2) How do hits from different fragment screening technologies and target classes compare with each other? (3) What is the best way to pair FBS assay technologies? In doing so, we identified substructures that were privileged for specific target classes, as well as fragments that were privileged for authentic activity against many targets. We also revealed some of the discrepancies between technologies. Finally, we uncovered a simple rule of thumb in screening strategy: when choosing two technologies for a campaign, pairing a biochemical and biophysical screen tends to yield the greatest coverage of authentic hits. © 2014 Society for Laboratory Automation and Screening.

  8. Small Screen Technology Use among Indigenous Boarding School Adolescents from Remote Regions of Western Australia

    ERIC Educational Resources Information Center

    Johnson, Genevieve Marie; Oliver, Rhonda

    2014-01-01

    The uptake of small screen technology by adolescents is widespread, particularly in industrial nations. Whether the same is true for Australian Aboriginal youth is less clear as there is a dearth of research in this regard. Therefore, in this exploratory study the use of small screen technology by Indigenous students was examined. Twenty-four…

  9. Acoustic Droplet Ejection Technology and Its Application in High-Throughput RNA Interference Screening.

    PubMed

    Nebane, N Miranda; Coric, Tatjana; McKellip, Sara; Woods, LaKeisha; Sosa, Melinda; Rasmussen, Lynn; Bjornsti, Mary-Ann; White, E Lucile

    2016-02-01

    The development of acoustic droplet ejection (ADE) technology has resulted in many positive changes associated with the operations in a high-throughput screening (HTS) laboratory. Originally, this liquid transfer technology was used to simply transfer DMSO solutions of primarily compounds. With the introduction of Labcyte's Echo 555, which has aqueous dispense capability, the application of this technology has been expanded beyond its original use. This includes the transfer of many biological reagents solubilized in aqueous buffers, including siRNAs. The Echo 555 is ideal for siRNA dispensing because it is accurate at low volumes and a step-down dilution is not necessary. The potential for liquid carryover and cross-contamination is eliminated, as no tips are needed. Herein, we describe the siRNA screening platform at Southern Research's HTS Center using the ADE technology. With this technology, an siRNA library can be dispensed weeks or even months in advance of the assay itself. The protocol has been optimized to achieve assay parameters comparable to small-molecule screening parameters, and exceeding the norm reported for genomewide siRNA screens. © 2015 Society for Laboratory Automation and Screening.

  10. CR digital mammography: an affordable entry.

    PubMed

    Fischer, Cathy

    2006-01-01

    CR full-field digital mammography (FFDM) has been used extensively in other countries, and it was one of the 4 digital mammography technologies employed in the Digital Mammographic Imaging Screening Trial. Affordability and easy integration with pre-existing mammography systems makes CR FFDM an attractive way to secure the advantages of filmless mammography imaging. CR mammography is true digital mammography--it is merely a different way of acquiring the image. The FDA has recently approved the first CR FFDM system for sale in the United States. At Gundersen Lutheran Health System (La Crosse, Wisconsin), CR FFDM is the most practical technology for realizing the potential everyday clinical benefits of filmless mammography imaging.

  11. Screening and selection of most potent diazotrophic cyanobacterial isolate exhibiting natural tolerance to rice field herbicides for exploitation as biofertilizer.

    PubMed

    Singh, Surendra; Datta, Pallavi

    2006-01-01

    Periodic applications of heavy dosages of herbicides in modern rice-agriculture are a necessary evil for obtaining high crop productivity. Such herbicides are not only detrimental to weeds but biofertilizer strains of diazotrophic cyanobacteria also. It is therefore, essential to screen and select such biofertilizer strains of diazotrophic cyanobacteria exhibiting natural tolerance to common rice-field herbicides that can be further improved by mutational techniques to make biofertilizer technology a viable one. Therefore, efforts have been made to screen five dominant diazotrophic cyanobacterial forms e.g. filamentous heterocystous Nostoc punctiforme , Nostoc calcicola , Anabaena variabilis and unicellular Gloeocapsa sp. and Aphanocapsa sp. along with standard laboratory strain Nostoc muscorum ISU against increasing concentrations (0-100 mg l(-1) of four commercial grade common rice-field herbicides i.e. Arozin, Butachlor, Alachlor and 2,4-D under diazotrophic growth conditions. The lethal and IGC(50) concentrations for all four herbicides tested were found highest for A. variabilis as compared to other test cyanobacteria. The lowest reduction in chlorophyll a content, photosynthetic oxygen evolution, and N(2)-fixation was found in A. variabilis as compared to other rice field isolates and standard laboratory strain N. muscorum ISU. On the basis of prolong survival potential and lowest reductions in vital metabolic activities tested at IGC(50) concentration of four herbicides, it is concluded that A. variabilis is the most potent and promising cyanobacterial isolate as compared with other forms. This could be further improved by mutational techniques for exploitation as most potential and viable biofertilizer strain.

  12. Antigen identification starting from the genome: a "Reverse Vaccinology" approach applied to MenB.

    PubMed

    Palumbo, Emmanuelle; Fiaschi, Luigi; Brunelli, Brunella; Marchi, Sara; Savino, Silvana; Pizza, Mariagrazia

    2012-01-01

    Most of the vaccines available today, albeit very effective, have been developed using traditional "old-style" methodologies. Technologies developed in recent years have opened up new perspectives in the field of vaccinology and novel strategies are now being used to design improved or new vaccines against infections for which preventive measures do not exist. The Reverse Vaccinology (RV) approach is one of the most powerful examples of biotechnology applied to the field of vaccinology for identifying new protein-based vaccines. RV combines the availability of genomic data, the analyzing capabilities of new bioinformatic tools, and the application of high throughput expression and purification systems combined with serological screening assays for a coordinated screening process of the entire genomic repertoire of bacterial, viral, or parasitic pathogens. The application of RV to Neisseria meningitidis serogroup B represents the first success of this novel approach. In this chapter, we describe how this revolutionary approach can be easily applied to any pathogen.

  13. Lectin engineering, a molecular evolutionary approach to expanding the lectin utilities.

    PubMed

    Hu, Dan; Tateno, Hiroaki; Hirabayashi, Jun

    2015-04-27

    In the post genomic era, glycomics--the systematic study of all glycan structures of a given cell or organism--has emerged as an indispensable technology in various fields of biology and medicine. Lectins are regarded as "decipherers of glycans", being useful reagents for their structural analysis, and have been widely used in glycomic studies. However, the inconsistent activity and availability associated with the plant-derived lectins that comprise most of the commercially available lectins, and the limit in the range of glycan structures covered, have necessitated the development of innovative tools via engineering of lectins on existing scaffolds. This review will summarize the current state of the art of lectin engineering and highlight recent technological advances in this field. The key issues associated with the strategy of lectin engineering including selection of template lectin, construction of a mutagenesis library, and high-throughput screening methods are discussed.

  14. From tissue to silicon to plastic: three-dimensional printing in comparative anatomy and physiology

    PubMed Central

    Lauridsen, Henrik; Hansen, Kasper; Nørgård, Mathias Ørum; Wang, Tobias; Pedersen, Michael

    2016-01-01

    Comparative anatomy and physiology are disciplines related to structures and mechanisms in three-dimensional (3D) space. For the past centuries, scientific reports in these fields have relied on written descriptions and two-dimensional (2D) illustrations, but in recent years 3D virtual modelling has entered the scene. However, comprehending complex anatomical structures is hampered by reproduction on flat inherently 2D screens. One way to circumvent this problem is in the production of 3D-printed scale models. We have applied computed tomography and magnetic resonance imaging to produce digital models of animal anatomy well suited to be printed on low-cost 3D printers. In this communication, we report how to apply such technology in comparative anatomy and physiology to aid discovery, description, comprehension and communication, and we seek to inspire fellow researchers in these fields to embrace this emerging technology. PMID:27069653

  15. An evaluation of suspicious powder screening tools for first responders.

    PubMed

    Poore, Carrie; Clark, Paul; Emanuel, Peter A

    2009-12-30

    Field screening tools are required which would allow first responders to quickly ascertain if a suspicious powder poses a potential threat necessitating additional testing for biological pathogens such as Bacillus anthracis. In this study, three commercially available generic screening technologies were evaluated for the effectiveness to accurately differentiate between a hoax powder and a true biological threat. The BioCheck Kit was able to detect the following biological agents 1 x 10(8)CFU of B. anthracis Sterne (washed 4 times), 1x10(7)CFU of B. anthracis DeltaSterne (washed 2 times), 1 x 10(7)CFU of Yersinia pestis A1122, and 100 microg of ricin. The Prime Alert kit was able to detect 2 x 10(10)CFU of B. anthracis DeltaSterne 4x, 1 x 10(9)CFU of B. anthracis DeltaSterne 2x, and 1 x 10(8)CFU of Y. pestis A1122. The Prime Alert kit was not able to detect ricin. The Profile-1 kit was able to detect 1 x 10(4)CFU of B. anthracis DeltaSterne 4x and B. anthracis DeltaSterne 2x, and 1 x 10(6)CFU of Y. pestis A1122. The Profile-1 kit was not able to detect ricin. All of the kits showed positive results for powders containing components specifically targeted by the particular technology being used. Each technology assessed in this evaluation employs a different mechanism for the detection of biological materials and it is important that first responders are aware of the strengths and the limitations of each system so that they can effectively employ the technology to protect the homeland.

  16. 76 FR 69595 - Application of Third Party Testing Requirements; Reducing Third Party Testing Burdens

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-08

    ... subject to a third party testing requirement. Please identify specific technologies, except for those that... evaluate testing or screening technologies for consumer products (e.g., accuracy, precision, repeatability... than testing technologies? Should screening technologies be allowed only for third party conformity...

  17. Modeling of luminance distribution in CAVE-type virtual reality systems

    NASA Astrophysics Data System (ADS)

    Meironke, Michał; Mazikowski, Adam

    2017-08-01

    At present, one of the most advanced virtual reality systems are CAVE-type (Cave Automatic Virtual Environment) installations. Such systems are usually consisted of four, five or six projection screens and in case of six screens arranged in form of a cube. Providing the user with a high level of immersion feeling in such systems is largely dependent of optical properties of the system. The modeling of physical phenomena plays nowadays a huge role in the most fields of science and technology. It allows to simulate work of device without a need to make any changes in the physical constructions. In this paper distribution of luminance in CAVE-type virtual reality systems were modelled. Calculations were performed for the model of 6-walled CAVE-type installation, based on Immersive 3D Visualization Laboratory, situated at the Faculty of Electronics, Telecommunications and Informatics at the Gdańsk University of Technology. Tests have been carried out for two different scattering distribution of the screen material in order to check how these characteristicinfluence on the luminance distribution of the whole CAVE. The basis assumption and simplification of modeled CAVE-type installation and results were presented. The brief discussion about the results and usefulness of developed model were also carried out.

  18. High-Content Screening for Quantitative Cell Biology.

    PubMed

    Mattiazzi Usaj, Mojca; Styles, Erin B; Verster, Adrian J; Friesen, Helena; Boone, Charles; Andrews, Brenda J

    2016-08-01

    High-content screening (HCS), which combines automated fluorescence microscopy with quantitative image analysis, allows the acquisition of unbiased multiparametric data at the single cell level. This approach has been used to address diverse biological questions and identify a plethora of quantitative phenotypes of varying complexity in numerous different model systems. Here, we describe some recent applications of HCS, ranging from the identification of genes required for specific biological processes to the characterization of genetic interactions. We review the steps involved in the design of useful biological assays and automated image analysis, and describe major challenges associated with each. Additionally, we highlight emerging technologies and future challenges, and discuss how the field of HCS might be enhanced in the future. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Applying remote sensing expertise to crop improvement: progress and challenges to scale up high throughput field phenotyping from research to industry

    NASA Astrophysics Data System (ADS)

    Gouache, David; Beauchêne, Katia; Mini, Agathe; Fournier, Antoine; de Solan, Benoit; Baret, Fred; Comar, Alexis

    2016-05-01

    Digital and image analysis technologies in greenhouses have become commonplace in plant science research and started to move into the plant breeding industry. However, the core of plant breeding work takes place in fields. We will present successive technological developments that have allowed the migration and application of remote sensing approaches at large into the field of crop genetics and physiology research, with a number of projects that have taken place in France. These projects have allowed us to develop combined sensor plus vector systems, from tractor mounted and UAV (unmanned aerial vehicle) mounted spectroradiometry to autonomous vehicle mounted spectroradiometry, RGB (red-green-blue) imagery and Lidar. We have tested these systems for deciphering the genetics of complex plant improvement targets such as the robustness to nitrogen and water deficiency of wheat and maize. Our results from wheat experiments indicate that these systems can be used both to screen genetic diversity for nitrogen stress tolerance and to decipher the genetics behind this diversity. We will present our view on the next critical steps in terms of technology and data analysis that will be required to reach cost effective implementation in industrial plant breeding programs. If this can be achieved, these technologies will largely contribute to resolving the equation of increasing food supply in the resource limited world that lies ahead.

  20. Detecting and overcoming systematic bias in high-throughput screening technologies: a comprehensive review of practical issues and methodological solutions.

    PubMed

    Caraus, Iurie; Alsuwailem, Abdulaziz A; Nadon, Robert; Makarenkov, Vladimir

    2015-11-01

    Significant efforts have been made recently to improve data throughput and data quality in screening technologies related to drug design. The modern pharmaceutical industry relies heavily on high-throughput screening (HTS) and high-content screening (HCS) technologies, which include small molecule, complementary DNA (cDNA) and RNA interference (RNAi) types of screening. Data generated by these screening technologies are subject to several environmental and procedural systematic biases, which introduce errors into the hit identification process. We first review systematic biases typical of HTS and HCS screens. We highlight that study design issues and the way in which data are generated are crucial for providing unbiased screening results. Considering various data sets, including the publicly available ChemBank data, we assess the rates of systematic bias in experimental HTS by using plate-specific and assay-specific error detection tests. We describe main data normalization and correction techniques and introduce a general data preprocessing protocol. This protocol can be recommended for academic and industrial researchers involved in the analysis of current or next-generation HTS data. © The Author 2015. Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.

  1. Contraband detection using acoustic technology

    NASA Astrophysics Data System (ADS)

    George, Robert D.; Gauthier, Ronald D.; Denslow, Kayte D.; Cinson, Anthony M.; Diaz, Aaron A.; Griffin, Molly

    2008-03-01

    Maritime security personnel have a need for advanced technologies to address issues such as identification, confirmation or classification of substances and materials in sealed containers, both non-invasively and nondestructively in field and first response operations. Such substances include items such as hazardous/flammable liquids, drugs, contraband, and precursor chemicals used in the fabrication of illicit materials. Our initial efforts focused specifically on a commercial portable acoustic detector technology that was evaluated under operational conditions in a maritime environment. Technical/operational limitations were identified and enhancements were incorporated that would address these limitations. In this paper, application-specific improvements and performance testing/evaluation results will be described. Such enhancements will provide personnel/users of the detector a significantly more reliable method of screening materials for contraband items that might be hidden in cargo containers.

  2. Innovation in academic chemical screening: filling the gaps in chemical biology.

    PubMed

    Hasson, Samuel A; Inglese, James

    2013-06-01

    Academic screening centers across the world have endeavored to discover small molecules that can modulate biological systems. To increase the reach of functional-genomic and chemical screening programs, universities, research institutes, and governments have followed their industrial counterparts in adopting high-throughput paradigms. As academic screening efforts have steadily grown in scope and complexity, so have the ideas of what is possible with the union of technology and biology. This review addresses the recent conceptual and technological innovation that has been propelling academic screening into its own unique niche. In particular, high-content and whole-organism screening are changing how academics search for novel bioactive compounds. Importantly, we recognize examples of successful chemical probe development that have punctuated the changing technology landscape. Published by Elsevier Ltd.

  3. Site characterization design and techniques used at the Southern Shipbuilding Corporation site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mueller, J.P.; Geraghty, C.A.; Moore, G.W.

    1995-12-31

    The Southern Shipbuilding Corporation (SSC) site is an inactive barge/ship manufacturing and repair facility situated on approximately 54 acres in Slidell, St. Tammany Parish, Louisiana. Two unlined surface impoundments (North and South impoundments) are situated on the northwest portion of the site and are surrounded on three sides by Bayou Bonfouca. These impoundments are the sources of carcinogenic polynuclear aromatic hydrocarbon (CPAH) contamination at the site. Inadequate containment has resulted in the release of impoundment wastes into the bayou. To evaluate potential response alternatives for the site, an Engineering Evaluation/Cost Analysis (EE/CA) field investigation was conducted from July through Octobermore » 1994. A two phase sampling approach was used in combination with innovative and traditional sampling techniques, field screening technologies, and exploitation of the visual characteristics of the waste to determine the extent of waste migration with limited off-site laboratory confirmation. A skid-mounted mobile drilling unit, secured to a specialized sampling platform designed for multiple applications, was used for collection of sediment cores from the bayou as well as tarry sludge cores from the impoundments. Field screening of core samples was accomplished on site using an organic vapor analyzer and a total petroleum hydrocarbon (TPH) field analyzer. Pollutants of concern include metals, cyanide, dioxin, and organic compounds. This paper presents details on the sampling design and characterization techniques used to accomplish the EE/CA field investigation.« less

  4. Human iPSC-derived cardiomyocytes and tissue engineering strategies for disease modeling and drug screening

    PubMed Central

    Smith, Alec S.T.; Macadangdang, Jesse; Leung, Winnie; Laflamme, Michael A.; Kim, Deok-Ho

    2016-01-01

    Improved methodologies for modeling cardiac disease phenotypes and accurately screening the efficacy and toxicity of potential therapeutic compounds are actively being sought to advance drug development and improve disease modeling capabilities. To that end, much recent effort has been devoted to the development of novel engineered biomimetic cardiac tissue platforms that accurately recapitulate the structure and function of the human myocardium. Within the field of cardiac engineering, induced pluripotent stem cells (iPSCs) are an exciting tool that offer the potential to advance the current state of the art, as they are derived from somatic cells, enabling the development of personalized medical strategies and patient specific disease models. Here we review different aspects of iPSC-based cardiac engineering technologies. We highlight methods for producing iPSC-derived cardiomyocytes (iPSC-CMs) and discuss their application to compound efficacy/toxicity screening and in vitro modeling of prevalent cardiac diseases. Special attention is paid to the application of micro- and nano-engineering techniques for the development of novel iPSC-CM based platforms and their potential to advance current preclinical screening modalities. PMID:28007615

  5. Robotic liquid handling and automation in epigenetics.

    PubMed

    Gaisford, Wendy

    2012-10-01

    Automated liquid-handling robots and high-throughput screening (HTS) are widely used in the pharmaceutical industry for the screening of large compound libraries, small molecules for activity against disease-relevant target pathways, or proteins. HTS robots capable of low-volume dispensing reduce assay setup times and provide highly accurate and reproducible dispensing, minimizing variation between sample replicates and eliminating the potential for manual error. Low-volume automated nanoliter dispensers ensure accuracy of pipetting within volume ranges that are difficult to achieve manually. In addition, they have the ability to potentially expand the range of screening conditions from often limited amounts of valuable sample, as well as reduce the usage of expensive reagents. The ability to accurately dispense lower volumes provides the potential to achieve a greater amount of information than could be otherwise achieved using manual dispensing technology. With the emergence of the field of epigenetics, an increasing number of drug discovery companies are beginning to screen compound libraries against a range of epigenetic targets. This review discusses the potential for the use of low-volume liquid handling robots, for molecular biological applications such as quantitative PCR and epigenetics.

  6. Determination of mercury in ambient water samples by anodic stripping voltammetry on screen-printed gold electrodes.

    PubMed

    Bernalte, E; Marín Sánchez, C; Pinilla Gil, E

    2011-03-09

    The applicability of commercial screen-printed gold electrodes (SPGEs) for the determination of Hg(II) in ambient water samples by square wave anodic stripping voltammetry has been demonstrated. Electrode conditioning procedures, chemical and instrumental variables have been optimized to develop a reliable method capable of measuring dissolved mercury in the low ng mL(-1) range (detection limit 1.1 ng mL(-1)), useful for pollution monitoring or screening purposes. The proposed method was tested with the NIST 1641d Mercury in Water Standard Reference Material (recoveries 90.0-110%) and the NCS ZC 76303 Mercury in Water Certified Reference Material (recoveries 82.5-90.6%). Waste water samples from industrial origin and fortified rain water samples were assayed for mercury by the proposed method and by a reference ICP-MS method, with good agreement. Screen printing technology thus opens a useful way for the construction of reliable electrochemical sensors for decentralized or even field Hg(II) testing. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. A high-resolution and intelligent dead pixel detection scheme for an electrowetting display screen

    NASA Astrophysics Data System (ADS)

    Luo, ZhiJie; Luo, JianKun; Zhao, WenWen; Cao, Yang; Lin, WeiJie; Zhou, GuoFu

    2018-02-01

    Electrowetting display technology is realized by tuning the surface energy of a hydrophobic surface by applying a voltage based on electrowetting mechanism. With the rapid development of the electrowetting industry, how to analyze efficiently the quality of an electrowetting display screen has a very important significance. There are two kinds of dead pixels on the electrowetting display screen. One is that the oil of pixel cannot completely cover the display area. The other is that indium tin oxide semiconductor wire connecting pixel and foil was burned. In this paper, we propose a high-resolution and intelligent dead pixel detection scheme for an electrowetting display screen. First, we built an aperture ratio-capacitance model based on the electrical characteristics of electrowetting display. A field-programmable gate array is used as the integrated logic hub of the system for a highly reliable and efficient control of the circuit. Dead pixels can be detected and displayed on a PC-based 2D graphical interface in real time. The proposed dead pixel detection scheme reported in this work has promise in automating electrowetting display experiments.

  8. Portable open-path optical remote sensing (ORS) Fourier transform infrared (FTIR) instrumentation miniaturization and software for point and click real-time analysis

    NASA Astrophysics Data System (ADS)

    Zemek, Peter G.; Plowman, Steven V.

    2010-04-01

    Advances in hardware have miniaturized the emissions spectrometer and associated optics, rendering them easily deployed in the field. Such systems are also suitable for vehicle mounting, and can provide high quality data and concentration information in minutes. Advances in software have accompanied this hardware evolution, enabling the development of portable point-and-click OP-FTIR systems that weigh less than 16 lbs. These systems are ideal for first-responders, military, law enforcement, forensics, and screening applications using optical remote sensing (ORS) methodologies. With canned methods and interchangeable detectors, the new generation of OP-FTIR technology is coupled to the latest forward reference-type model software to provide point-and-click technology. These software models have been established for some time. However, refined user-friendly models that use active, passive, and solar occultation methodologies now allow the user to quickly field-screen and quantify plumes, fence-lines, and combustion incident scenarios in high-temporal-resolution. Synthetic background generation is now redundant as the models use highly accurate instrument line shape (ILS) convolutions and several other parameters, in conjunction with radiative transfer model databases to model a single calibration spectrum to collected sample spectra. Data retrievals are performed directly on single beam spectra using non-linear classical least squares (NLCLS). Typically, the Hitran line database is used to generate the initial calibration spectrum contained within the software.

  9. Induced pluripotent stem cell technology: a decade of progress.

    PubMed

    Shi, Yanhong; Inoue, Haruhisa; Wu, Joseph C; Yamanaka, Shinya

    2017-02-01

    Since the advent of induced pluripotent stem cell (iPSC) technology a decade ago, enormous progress has been made in stem cell biology and regenerative medicine. Human iPSCs have been widely used for disease modelling, drug discovery and cell therapy development. Novel pathological mechanisms have been elucidated, new drugs originating from iPSC screens are in the pipeline and the first clinical trial using human iPSC-derived products has been initiated. In particular, the combination of human iPSC technology with recent developments in gene editing and 3D organoids makes iPSC-based platforms even more powerful in each area of their application, including precision medicine. In this Review, we discuss the progress in applications of iPSC technology that are particularly relevant to drug discovery and regenerative medicine, and consider the remaining challenges and the emerging opportunities in the field.

  10. Smart DNA Fabrication Using Sound Waves

    PubMed Central

    Kanigowska, Paulina; Shen, Yue; Zheng, Yijing; Rosser, Susan; Cai, Yizhi

    2016-01-01

    Acoustic droplet ejection (ADE) technology uses focused acoustic energy to transfer nanoliter-scale liquid droplets with high precision and accuracy. This noncontact, tipless, low-volume dispensing technology minimizes the possibility of cross-contamination and potentially reduces the costs of reagents and consumables. To date, acoustic dispensers have mainly been used in screening libraries of compounds. In this paper, we describe the first application of this powerful technology to the rapidly developing field of synthetic biology, for DNA synthesis and assembly at the nanoliter scale using a Labcyte Echo 550 acoustic dispenser. We were able to successfully downscale PCRs and the popular one-pot DNA assembly methods, Golden Gate and Gibson assemblies, from the microliter to the nanoliter scale with high assembly efficiency, which effectively cut the reagent cost by 20- to 100-fold. We envision that acoustic dispensing will become an instrumental technology in synthetic biology, in particular in the era of DNA foundries. PMID:26163567

  11. An information technology emphasis in biomedical informatics education.

    PubMed

    Kane, Michael D; Brewer, Jeffrey L

    2007-02-01

    Unprecedented growth in the interdisciplinary domain of biomedical informatics reflects the recent advancements in genomic sequence availability, high-content biotechnology screening systems, as well as the expectations of computational biology to command a leading role in drug discovery and disease characterization. These forces have moved much of life sciences research almost completely into the computational domain. Importantly, educational training in biomedical informatics has been limited to students enrolled in the life sciences curricula, yet much of the skills needed to succeed in biomedical informatics involve or augment training in information technology curricula. This manuscript describes the methods and rationale for training students enrolled in information technology curricula in the field of biomedical informatics, which augments the existing information technology curriculum and provides training on specific subjects in Biomedical Informatics not emphasized in bioinformatics courses offered in life science programs, and does not require prerequisite courses in the life sciences.

  12. Photoaligning and photopatterning technology: applications in displays and photonics

    NASA Astrophysics Data System (ADS)

    Chigrinov, Vladimir

    2016-03-01

    The advantages of LC photoalignment technology in comparison with common "rubbing" alignment methods tend to the continuation of the research in this field. Almost all the criteria of perfect LC alignment are met in case of azo-dye layers. Nowadays azo-dye alignment materials can be already used in LCD manufacturing, e.g. for the alignment of monomers in LCP films for new generations of photonics and optics devices. Recently the new application of photoaligned technology for the tunable LC lenses with a variable focal distance was proposed. New optically rewritable (ORW) liquid crystal display and photonics devices with a light controllable structure may include LC E-paper screens, LC lenses with a variable focal distance etc. Fast ferroelectric liquid crystal devices (FLCD) are achieved through the application of nano-scale photo aligning (PA) layers in FLC cells. The novel photoaligned FLC devices may include field sequential color (FSC) FLC with a high resolution, high brightness, low power consumption and extended color gamut to be used for PCs, PDAs, switchable goggles, and new generation of switchable 2D/3D LCD TVs, as well as photonics elements.

  13. Movie magic in the clinic: computer-generated characters for automated health counseling.

    PubMed

    Bickmore, Timothy

    2008-11-06

    In this presentation, I demonstrate how many of the technologies used in movie special effects and games have been successfully used in health education and behavior change interventions. Computer-animated health counselors simulate human face-to-face dialogue as a computer interface medium, including not only verbal behavior but nonverbal conversational behavior such as hand gesture, body posture shifts, and facial display of emotion. This technology has now been successfully used in a wide range of health interventions for education and counseling of patients and consumers, including applications in physical activity promotion, medication adherence, and hospital discharge. These automated counselors have been deployed on home computers, hospital-based touch screen kiosks, and mobile devices with integrated health behavior sensing capability. Development of these agents is an interdisciplinary endeavor spanning the fields of character modeling and animation, computational linguistics, artificial intelligence, health communication and behavioral medicine. I will give demonstrations of several fielded systems, describe the technologies and methodologies underlying their development, and present results from five randomized controlled trials that have been completed or are in progress.

  14. Recommendations for successful sensory screening in older adults with dementia in long-term care: a qualitative environmental scan of Canadian specialists.

    PubMed

    Wittich, Walter; Höbler, Fiona; Jarry, Jonathan; McGilton, Katherine S

    2018-01-26

    This study aimed to identify screening tools, technologies and strategies that vision and hearing care specialists recommend to front-line healthcare professionals for the screening of older adults in long-term care homes who have dementia. An environmental scan of healthcare professionals took place via telephone interviews between December 2015 and March 2016. All interviews were audio recorded, transcribed, proofed for accuracy, and their contents thematically analysed by two members of the research team. A convenience sample of 11 professionals from across Canada specialising in the fields of vision and hearing healthcare and technology for older adults with cognitive impairment were included in the study. As part of a larger mixed-methods project, this qualitative study used semistructured interviews and their subsequent content analysis. Following a two-step content analysis of interview data, coded citations were grouped into three main categories: (1) barriers, (2) facilitators and (3) tools and strategies that do or do not work for sensory screening of older adults with dementia. We report on the information offered by participants within each of these themes, along with a summary of tools and strategies that work for screening older adults with dementia. Recommendations from sensory specialists to nurses working in long-term care included the need for improved interprofessional communication and collaboration, as well as flexibility, additional time and strategic use of clinical intuition and ingenuity. These suggestions at times contradicted the realities of service provision or the need for standardised and validated measures. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. Extending the Global Dialogue about Media, Technology, Screen Time, and Young Children

    ERIC Educational Resources Information Center

    Ernest, James M.; Causey, Cora; Newton, Allison B.; Sharkins, Kimberly; Summerlin, Jennifer; Albaiz, Najla

    2014-01-01

    Questions about the potential benefits and dangers of media and technology use abound, with competing theories regarding its effects among young children. This article explores global perspectives on children's exposure to media, technology, and screen time (MeTS) in the schools, homes, and communities of an increasingly technology-driven world.…

  16. Advances in cervical screening technology.

    PubMed

    Stoler, M H

    2000-03-01

    The Pap smear unquestionably is a successful screening test for cervical cancer. However, recent advances in technology have raised questions regarding whether the conventional Pap smear is still the standard of care. This article relates issues of screening and cost-effectiveness to the state of the art in thin layer preparations, cytology automation, human papillomavirus screening, human papillomavirus vaccines, and other cervical screening adjuncts. Perhaps nowhere in medicine is clinical decision making being more strongly influenced by market and other external forces than in cervical cytopathology.

  17. On determining specifications and selections of alternative technologies for airport checked-baggage security screening.

    PubMed

    Feng, Qianmei

    2007-10-01

    Federal law mandates that every checked bag at all commercial airports be screened by explosive detection systems (EDS), explosive trace detection systems (ETD), or alternative technologies. These technologies serve as critical components of airport security systems that strive to reduce security risks at both national and global levels. To improve the operational efficiency and airport security, emerging image-based technologies have been developed, such as dual-energy X-ray (DX), backscatter X-ray (BX), and multiview tomography (MVT). These technologies differ widely in purchasing cost, maintenance cost, operating cost, processing rate, and accuracy. Based on a mathematical framework that takes into account all these factors, this article investigates two critical issues for operating screening devices: setting specifications for continuous security responses by different technologies; and selecting technology or combination of technologies for efficient 100% baggage screening. For continuous security responses, specifications or thresholds are used for classifying threat items from nonthreat items. By investigating the setting of specifications on system security responses, this article assesses the risk and cost effectiveness of various technologies for both single-device and two-device systems. The findings provide the best selection of image-based technologies for both single-device and two-device systems. Our study suggests that two-device systems outperform single-device systems in terms of both cost effectiveness and accuracy. The model can be readily extended to evaluate risk and cost effectiveness of multiple-device systems for airport checked-baggage security screening.

  18. Internet-Based Cervical Cytology Screening System

    DTIC Science & Technology

    2007-04-01

    approaches to cervical cancer screening possible. In addition, advances in information technology have facilitated the Internet transmission and archival...processes in the clinical laboratory. Recent technological advances in specimen preparation and computerized primary screening make automated...AD_________________ Award Number: W81XWH-04-C-0083 TITLE: Internet -Based Cervical Cytology

  19. Apparel Research Network (ARN); Apparel Order Processing Module (AOPM): Field User Manual, Version 1

    DTIC Science & Technology

    1997-09-30

    changes. Cancel Button Closes the Site Information Screen, abandoning changes. APPAREL ORDER PROCESSING MODULE FIELD USER MANUAL Ordering Official...on the Ordering Official Information Screen. APPAREL ORDER PROCESSING MODULE FIELD USER MANUAL Ordering Official Information Screen (Jjj

  20. Parental perceptions of technology and technology-focused parenting: Associations with youth screen time

    PubMed Central

    Sanders, Wesley; Parent, Justin; Forehand, Rex; Sullivan, Alexandra D.W.; Jones, Deborah J.

    2016-01-01

    In the present study we propose a model linking parental perceptions of technology to technology-related parenting strategies to youth screen time, and, finally, to internalizing and externalizing problem behaviors. Participants were 615 parents drawn from three community samples of families with children across three developmental stages: young childhood, middle childhood, and adolescence. The model was tested at each stage with the strongest support emerging in the young childhood sample. One component of parental perceptions of technology, perceived efficacy, was related to technology-related parenting strategies across developmental stages. However, the association of these strategies to child screen time and, in turn, problem behaviors, diminished as children increased in age. Implications for intervention are considered. PMID:27795603

  1. Technology Addiction among Treatment Seekers for Psychological Problems: Implication for Screening in Mental Health Setting.

    PubMed

    Das, Aswathy; Sharma, Manoj Kumar; Thamilselvan, P; Marimuthu, P

    2017-01-01

    Technology usage has seen an increase among users. The usage varies from social, personal, and psychological reasons. Users are frequently using to overcome mood states as well as to manage the other psychological states. This work is going to explore the information technology use among subjects with a psychiatric disorder. A total of 75 subjects were assessed using background data sheet, internet addiction impairment index, video game use pattern, pornography addiction screening tool and screening for mobile phone use, from in-patient and out-patient setting of tertiary mental health setting. It showed the presence of addiction to mobile, internet, video game, and pornography. Age was found to be negatively correlated with this addiction. Average usage time had been associated with management of mood states. The addiction to information technology had been associated with a delay in initiation of sleep. This work has implication for screening technology addiction among subjects seeking treatment for psychological problems and motivate them to develop the healthy use of technology.

  2. Oncotyrol--Center for Personalized Cancer Medicine: Methods and Applications of Health Technology Assessment and Outcomes Research.

    PubMed

    Siebert, Uwe; Jahn, Beate; Rochau, Ursula; Schnell-Inderst, Petra; Kisser, Agnes; Hunger, Theresa; Sroczynski, Gaby; Mühlberger, Nikolai; Willenbacher, Wolfgang; Schnaiter, Simon; Endel, Gottfried; Huber, Lukas; Gastl, Guenther

    2015-01-01

    The Oncotyrol - Center for Personalized Cancer Medicine is an international and interdisciplinary alliance combining research and commercial competencies to accelerate the development, evaluation and translation of personalized healthcare strategies in cancer. The philosophy of Oncotyrol is to collaborate with relevant stakeholders and advance knowledge "from bench to bedside to population and back". Oncotyrol is funded through the COMET Excellence Program by the Austrian government via the national Austrian Research Promotion Agency (FFG). This article focuses on the role of health technology assessment (HTA) and outcomes research in personalized cancer medicine in the context of Oncotyrol. Oncotyrol, which currently comprises approximately 20 individual projects, has four research areas: Area 1: Biomarker and Drug Target Identification; Area 2: Assay Development and Drug Screening; Area 3: Innovative Therapies; Area 4: Health Technology Assessment and Bioinformatics. Area 4 translates the results from Areas 1 to 3 to populations and society and reports them back to Area 3 to inform clinical studies and guidelines, and to Areas 1 and 2 to guide further research and development. In a series of international expert workshops, the Oncotyrol International Expert Task Force for Personalized Cancer Medicine developed the Methodological Framework for Early Health Technology Assessment and Decision Modeling in Cancer and practical guidelines in this field. Further projects included applications in the fields of sequential treatment of patients with chronic myeloid leukemia (CML), benefit-harm and cost-effectiveness evaluation of prostate cancer screening, effectiveness and cost-effectiveness of multiple cervical cancer screening strategies, and benefits and cost-effectiveness of genomic test-based treatment strategies in breast cancer. An interdisciplinary setting as generated in Oncotyrol provides unique opportunities such as systematically coordinating lab and bench research, product development, clinical studies and decision science/HTA and transparent joint planning of research and development with a partnership of researchers, manufacturers and health policy decision makers. However, generating a joint research and legal framework with numerous partners from different sectors can be challenging, particularly in the starting period of such an endeavor. The journey to translational personalized medicine through multidisciplinary collaborations may still be long and difficult, but it is evident that it must be continued to turn vision into reality. Copyright © 2015. Published by Elsevier GmbH.

  3. Chemical Sniffing Instrumentation for Security Applications.

    PubMed

    Giannoukos, Stamatios; Brkić, Boris; Taylor, Stephen; Marshall, Alan; Verbeck, Guido F

    2016-07-27

    Border control for homeland security faces major challenges worldwide due to chemical threats from national and/or international terrorism as well as organized crime. A wide range of technologies and systems with threat detection and monitoring capabilities has emerged to identify the chemical footprint associated with these illegal activities. This review paper investigates artificial sniffing technologies used as chemical sensors for point-of-use chemical analysis, especially during border security applications. This article presents an overview of (a) the existing available technologies reported in the scientific literature for threat screening, (b) commercially available, portable (hand-held and stand-off) chemical detection systems, and (c) their underlying functional and operational principles. Emphasis is given to technologies that have been developed for in-field security operations, but laboratory developed techniques are also summarized as emerging technologies. The chemical analytes of interest in this review are (a) volatile organic compounds (VOCs) associated with security applications (e.g., illegal, hazardous, and terrorist events), (b) chemical "signatures" associated with human presence, and (c) threat compounds (drugs, explosives, and chemical warfare agents).

  4. Fetal aneuploidy detection by maternal plasma DNA sequencing: a technology assessment.

    PubMed

    Walsh, Judith M E; Goldberg, James D

    2013-06-01

    The American College of Obstetricians and Gynecologists currently recommends that all pregnant women be offered screening for chromosomal abnormalities, regardless of maternal age. Traditional screening tests have detection rates ranging from 85% to 90% and false-positive rates of 3% to 5%. A woman with an abnormal noninvasive test is offered a diagnostic test, but diagnostic tests are associated with a risk of pregnancy loss. Recently, analysis of cell-free fetal DNA (cffDNA) in maternal blood has been shown to have potential for the accurate detection of some of the common fetal autosomal aneuploidies. As part of a technology assessment for the California Technology Assessment Forum, we critically reviewed the evidence for the use of cffDNA as a prenatal screening test. We evaluated the evidence for its use as either a 'primary' or an 'advanced' screening test and for its use in screening for three different trisomies: 21, 18, and 13. We evaluated whether the use of cffDNA met established technology assessment criteria and established conclusions about evidence-based use of this new technology. © 2013 John Wiley & Sons, Ltd.

  5. Awareness, Interest, and Preferences of Primary Care Providers in Using Point-of-Care Cancer Screening Technology.

    PubMed

    Kim, Chloe S; Vanture, Sarah; Cho, Margaret; Klapperich, Catherine M; Wang, Catharine; Huang, Franklin W

    2016-01-01

    Well-developed point-of-care (POC) cancer screening tools have the potential to provide better cancer care to patients in both developed and developing countries. However, new medical technology will not be adopted by medical providers unless it addresses a population's existing needs and end-users' preferences. The goals of our study were to assess primary care providers' level of awareness, interest, and preferences in using POC cancer screening technology in their practice and to provide guidelines to biomedical engineers for future POC technology development. A total of 350 primary care providers completed a one-time self-administered online survey, which took approximately 10 minutes to complete. A $50 Amazon gift card was given as an honorarium for the first 100 respondents to encourage participation. The description of POC cancer screening technology was provided in the beginning of the survey to ensure all participants had a basic understanding of what constitutes POC technology. More than half of the participants (57%) stated that they heard of the term "POC technology" for the first time when they took the survey. However, almost all of the participants (97%) stated they were either "very interested" (68%) or "somewhat interested" (29%) in using POC cancer screening technology in their practice. Demographic characteristics such as the length of being in the practice of medicine, the percentage of patients on Medicaid, and the average number of patients per day were not shown to be associated with the level of interest in using POC. These data show that there is a great interest in POC cancer screening technology utilization among this population of primary care providers and vast room for future investigations to further understand the interest and preferences in using POC cancer technology in practice. Ensuring that the benefits of new technology outweigh the costs will maximize the likelihood it will be used by medical providers and patients.

  6. Air Vehicle Integration and Technology Research (AVIATR). Delivery Order 0023: Predictive Capability for Hypersonic Structural Response and Life Prediction: Phase 2 - Detailed Design of Hypersonic Cruise Vehicle Hot-Structure

    DTIC Science & Technology

    2012-05-01

    30 Figure 5.0.1 Phase II Analysis Process ...panel study the panel selection process followed a review of the outer skin environment investigated during the HTV-3X program which was suitable as...Subsequently, Panel 1B was down-selected from the screening process as it was observed to be subjected to stronger thermal field contributions due to fuel

  7. Field Guide: The Culture of the Chinese People’s Liberation Army

    DTIC Science & Technology

    2009-02-01

    technologies , and were knowledgeable on a wide range of subjects 44 Remedy: Add new officer accession paths. The PLA aspires to draw many more officer...needs only a few hundred thousand new conscripts. There are many ways of avoiding conscription; in the end, few people join the military who really...training are carried out as part of an annual cycle: • On November 1, potential conscripts report for screening. • By around February 1, new conscripts

  8. Photorefraction Screens Millions for Vision Disorders

    NASA Technical Reports Server (NTRS)

    2008-01-01

    Who would have thought that stargazing in the 1980s would lead to hundreds of thousands of schoolchildren seeing more clearly today? Collaborating with research ophthalmologists and optometrists, Marshall Space Flight Center scientists Joe Kerr and the late John Richardson adapted optics technology for eye screening methods using a process called photorefraction. Photorefraction consists of delivering a light beam into the eyes where it bends in the ocular media, hits the retina, and then reflects as an image back to a camera. A series of refinements and formal clinical studies followed their highly successful initial tests in the 1980s. Evaluating over 5,000 subjects in field tests, Kerr and Richardson used a camera system prototype with a specifically angled telephoto lens and flash to photograph a subject s eye. They then analyzed the image, the cornea and pupil in particular, for irregular reflective patterns. Early tests of the system with 1,657 Alabama children revealed that, while only 111 failed the traditional chart test, Kerr and Richardson s screening system found 507 abnormalities.

  9. Unsupervised self-testing as part public health screening for HIV in resource-poor environments: some ethical considerations.

    PubMed

    Scott, P Anne

    2014-07-01

    The use of unsupervised self-testing as part of a national screening program for HIV infection in resource-poor environments with high HIV prevalence may have a number of attractive aspects, such as increasing access to services for hard to reach and isolated populations. However, the presence of such technologies is at a relatively early stage in terms of use and impact in the field. In this paper, a principle-based approach, that recognizes the fundamentally utilitarian nature of public health combined with a focus on autonomy, is used as a lens to explore some of the ethical issues raised by HIV self-testing. The conclusion reached in this review is that at this point in time, on the basis of the principles of utility and respect for autonomy, it is not ethically appropriate to incorporate unsupervised HIV self-testing as part of a public health screening program in resource-poor environments.

  10. High-content screening for the discovery of pharmacological compounds: advantages, challenges and potential benefits of recent technological developments.

    PubMed

    Soleilhac, Emmanuelle; Nadon, Robert; Lafanechere, Laurence

    2010-02-01

    Screening compounds with cell-based assays and microscopy image-based analysis is an approach currently favored for drug discovery. Because of its high information yield, the strategy is called high-content screening (HCS). This review covers the application of HCS in drug discovery and also in basic research of potential new pathways that can be targeted for treatment of pathophysiological diseases. HCS faces several challenges, however, including the extraction of pertinent information from the massive amount of data generated from images. Several proposed approaches to HCS data acquisition and analysis are reviewed. Different solutions from the fields of mathematics, bioinformatics and biotechnology are presented. Potential applications and limits of these recent technical developments are also discussed. HCS is a multidisciplinary and multistep approach for understanding the effects of compounds on biological processes at the cellular level. Reliable results depend on the quality of the overall process and require strong interdisciplinary collaborations.

  11. Affordable proteomics: the two-hybrid systems.

    PubMed

    Gillespie, Marc

    2003-06-01

    Numerous proteomic methodologies exist, but most require a heavy investment in expertise and technology. This puts these approaches out of reach for many laboratories and small companies, rarely allowing proteomics to be used as a pilot approach for biomarker or target identification. Two proteomic approaches, 2D gel electrophoresis and the two-hybrid systems, are currently available to most researchers. The two-hybrid systems, though accommodating to large-scale experiments, were originally designed as practical screens, that by comparison to current proteomics tools were small-scale, affordable and technically feasible. The screens rapidly generated data, identifying protein interactions that were previously uncharacterized. The foundation for a two-hybrid proteomic investigation can be purchased as separate kits from a number of companies. The true power of the technique lies not in its affordability, but rather in its portability. The two-hybrid system puts proteomics back into laboratories where the output of the screens can be evaluated by researchers with experience in the particular fields of basic research, cancer biology, toxicology or drug development.

  12. Real-time interactive projection system based on infrared structured-light method

    NASA Astrophysics Data System (ADS)

    Qiao, Xiaorui; Zhou, Qian; Ni, Kai; He, Liang; Wu, Guanhao; Mao, Leshan; Cheng, Xuemin; Ma, Jianshe

    2012-11-01

    Interactive technologies have been greatly developed in recent years, especially in projection field. However, at present, most interactive projection systems are based on special designed interactive pens or whiteboards, which is inconvenient and limits the improvement of user experience. In this paper, we introduced our recent progress on theoretically modeling a real-time interactive projection system. The system permits the user to easily operate or draw on the projection screen directly by fingers without any other auxiliary equipment. The projector projects infrared striping patterns onto the screen and the CCD captures the deformational image. We resolve the finger's position and track its movement by processing the deformational image in real-time. A new way to determine whether the finger touches the screen is proposed. The first deformational fringe on the fingertip and the first fringe at the finger shadow are the same one. The correspondence is obtained, so the location parameters can be decided by triangulation. The simulation results are given, and errors are analyzed.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Durham, M.D.

    The purpose of this research program is to identify and evaluate a variety of additives capable of increasing particle cohesion which could be used for improving collection efficiency in an ESP. A three-phase screening process will be used to provide the, evaluation of many additives in a logical and cost-effective manner. The three step approach involves the following experimental setups: 1. Provide a preliminary screening in the laboratory by measuring the effects of various conditioning agents on reentrainment of flyash particles in an electric field operating at simulated flue gas conditions. 2. Evaluate the successful additives using a 100 acfmmore » bench-scale ESP operating on actual flue gas. 3. Obtain the data required for scaling up the technology by testing the two or three most promising conditioning agents at the pilot scale.« less

  14. A Sign Language Screen Reader for Deaf

    NASA Astrophysics Data System (ADS)

    El Ghoul, Oussama; Jemni, Mohamed

    Screen reader technology has appeared first to allow blind and people with reading difficulties to use computer and to access to the digital information. Until now, this technology is exploited mainly to help blind community. During our work with deaf people, we noticed that a screen reader can facilitate the manipulation of computers and the reading of textual information. In this paper, we propose a novel screen reader dedicated to deaf. The output of the reader is a visual translation of the text to sign language. The screen reader is composed by two essential modules: the first one is designed to capture the activities of users (mouse and keyboard events). For this purpose, we adopted Microsoft MSAA application programming interfaces. The second module, which is in classical screen readers a text to speech engine (TTS), is replaced by a novel text to sign (TTSign) engine. This module converts text into sign language animation based on avatar technology.

  15. Technologic advances for evaluation of cervical cytology: is newer better?

    PubMed

    Hartmann, K E; Nanda, K; Hall, S; Myers, E

    2001-12-01

    Among those women who have cervical cancer and have been screened, 14% to 33% of the cases represent failure to detect abnormalities that existed at the time of screening. New technologies intended to improve detection of cytologic abnormalities include liquid-based, thin-layer cytology (ThinPrep, AutoCyte), computerized rescreening (PAPNET), and algorithm-based computer rescreening (AutoPap). This report combines evidence reviews conducted for the U.S. Preventive Services Task Force and the Agency for Healthcare Research and Quality, in which we systematically identified articles on cervical neoplasia, cervical dysplasia, and screening published between January 1966 and March 2001. We note the challenges for improving screening methods, providing an overview of methods for collecting and evaluating cytologic samples, and examining the evidence about the diagnostic performance of new technologies for detecting cervical lesions. Using standard criteria for evaluation of the diagnostic tests, we determined that knowledge about the sensitivity, specificity, and predictive values of new technologies is meager. Only one study of liquid-based cytology used a reference standard of colposcopy, with histology as indicated, to assess participants with normal screening results. Lack of an adequate reference standard is the overwhelming reason that test characteristics cannot be properly assessed or compared. Most publications compare results of screening using the new technology with expert panel review of the cytologic specimen. In that case, the tests are not independent measures and do nothing to relate the screening test findings to the true status of the cervix, making determination of false-negatives, and thus sensitivity, specificity, and negative predictive value, impossible. We did not identify any literature about health outcomes or cost effectiveness of using these tools in a system of screening. For the purposes of guiding decision making about choice of screening tools, the current evidence is inadequate to gauge whether new technologies are "better" than conventional cytology..

  16. Surface plasmon resonance as a tool for ligand-binding assay reagent characterization in bioanalysis of biotherapeutics.

    PubMed

    Duo, Jia; Bruno, JoAnne; Kozhich, Alexander; David-Brown, Donata; Luo, Linlin; Kwok, Suk; Santockyte, Rasa; Haulenbeek, Jonathan; Liu, Rong; Hamuro, Lora; Peterson, Jon E; Piccoli, Steven; DeSilva, Binodh; Pillutla, Renuka; Zhang, Yan J

    2018-04-01

    Ligand-binding assay (LBA) performance depends on quality reagents. Strategic reagent screening and characterization is critical to LBA development, optimization and validation. Application of advanced technologies expedites the reagent screening and assay development process. By evaluating surface plasmon resonance technology that offers high-throughput kinetic information, this article aims to provide perspectives on applying the surface plasmon resonance technology to strategic LBA critical reagent screening and characterization supported by a number of case studies from multiple biotherapeutic programs.

  17. Total-Internal-Reflection Platforms for Chemical and Biological Sensing Applications

    NASA Astrophysics Data System (ADS)

    Sapsford, Kim E.

    Sensing platforms based on the principle of total internal reflection (TIR) represent a fairly mature yet still expanding and exciting field of research. Sensor development has mainly been driven by the need for rapid, stand-alone, automated devices for application in the fields of clinical diagnosis and screening, food and water safety, environmental monitoring, and chemical and biological warfare agent detection. The technologies highlighted in this chapter are continually evolving, taking advantage of emerging advances in microfabrication, lab-on-a-chip, excitation, and detection techniques. This chapter describes many of the underlying principles of TIR-based sensing platforms and additionally focusses on planar TIR fluorescence (TIRF)-based chemical and biological sensors.

  18. A new framework for interactive quality assessment with application to light field coding

    NASA Astrophysics Data System (ADS)

    Viola, Irene; Ebrahimi, Touradj

    2017-09-01

    In recent years, light field has experienced a surge of popularity, mainly due to the recent advances in acquisition and rendering technologies that have made it more accessible to the public. Thanks to image-based rendering techniques, light field contents can be rendered in real time on common 2D screens, allowing virtual navigation through the captured scenes in an interactive fashion. However, this richer representation of the scene poses the problem of reliable quality assessments for light field contents. In particular, while subjective methodologies that enable interaction have already been proposed, no work has been done on assessing how users interact with light field contents. In this paper, we propose a new framework to subjectively assess the quality of light field contents in an interactive manner and simultaneously track users behaviour. The framework is successfully used to perform subjective assessment of two coding solutions. Moreover, statistical analysis performed on the results shows interesting correlation between subjective scores and average interaction time.

  19. Design of a Novel Low Cost Point of Care Tampon (POCkeT) Colposcope for Use in Resource Limited Settings

    PubMed Central

    Lam, Christopher T.; Krieger, Marlee S.; Gallagher, Jennifer E.; Asma, Betsy; Muasher, Lisa C.; Schmitt, John W.; Ramanujam, Nimmi

    2015-01-01

    Introduction Current guidelines by WHO for cervical cancer screening in low- and middle-income countries involves visual inspection with acetic acid (VIA) of the cervix, followed by treatment during the same visit or a subsequent visit with cryotherapy if a suspicious lesion is found. Implementation of these guidelines is hampered by a lack of: trained health workers, reliable technology, and access to screening facilities. A low cost ultra-portable Point of Care Tampon based digital colposcope (POCkeT Colposcope) for use at the community level setting, which has the unique form factor of a tampon, can be inserted into the vagina to capture images of the cervix, which are on par with that of a state of the art colposcope, at a fraction of the cost. A repository of images to be compiled that can be used to empower front line workers to become more effective through virtual dynamic training. By task shifting to the community setting, this technology could potentially provide significantly greater cervical screening access to where the most vulnerable women live. The POCkeT Colposcope’s concentric LED ring provides comparable white and green field illumination at a fraction of the electrical power required in commercial colposcopes. Evaluation with standard optical imaging targets to assess the POCkeT Colposcope against the state of the art digital colposcope and other VIAM technologies. Results Our POCkeT Colposcope has comparable resolving power, color reproduction accuracy, minimal lens distortion, and illumination when compared to commercially available colposcopes. In vitro and pilot in vivo imaging results are promising with our POCkeT Colposcope capturing comparable quality images to commercial systems. Conclusion The POCkeT Colposcope is capable of capturing images suitable for cervical lesion analysis. Our portable low cost system could potentially increase access to cervical cancer screening in limited resource settings through task shifting to community health workers. PMID:26332673

  20. Large-screen display technology assessment for military applications

    NASA Astrophysics Data System (ADS)

    Blaha, Richard J.

    1990-08-01

    Full-color, large screen display systems can enhance military applications that require group presentation, coordinated decisions, or interaction between decision makers. The technology already plays an important role in operations centers, simulation facilities, conference rooms, and training centers. Some applications display situational, status, or briefing information, while others portray instructional material for procedural training or depict realistic panoramic scenes that are used in simulators. While each specific application requires unique values of luminance, resolution, response time, reliability, and the video interface, suitable performance can be achieved with available commercial large screen displays. Advances in the technology of large screen displays are driven by the commercial applications because the military applications do not provide the significant market share enjoyed by high definition television (HDTV), entertainment, advertisement, training, and industrial applications. This paper reviews the status of full-color, large screen display technologies and includes the performance and cost metrics of available systems. For this discussion, performance data is based upon either measurements made by our personnel or extractions from vendors' data sheets.

  1. Neuroleadership: Themes and limitations of an emerging interdisciplinary field.

    PubMed

    Kuhlmann, Naila; Kadgien, Chelsie A

    2018-05-01

    The relationship between brain and behaviour has perplexed philosophers and scientists since the time of the ancient Greeks. Recent technological advances have allowed neuroscience to flourish, alongside growing romanticism that reductionist studies will allow us to understand complex interpersonal behaviours. Organizational cognitive neuroscience and neuroleadership are newly established interdisciplinary fields that use neuroscientific techniques to answer questions about behaviours within organizations. Neuroleadership aims to discover screening tools for good leaders, to improve leadership skills, and to identify unconscious factors affecting behaviour in hopes of improving management and leadership practices. Although proponents of neuroleadership are optimistic, if we know anything about the functions of the human brain and our interpersonal behaviours, it is that they are exquisitely complex and context dependant. Here, we briefly discuss the major themes emerging in the new field of neuroleadership and the limitations and potential consequences of applying findings from the field prematurely and with blind optimism.

  2. Awareness, Interest, and Preferences of Primary Care Providers in Using Point-of-Care Cancer Screening Technology

    PubMed Central

    Kim, Chloe S.; Vanture, Sarah; Cho, Margaret; Klapperich, Catherine M.; Wang, Catharine; Huang, Franklin W.

    2016-01-01

    Well-developed point-of-care (POC) cancer screening tools have the potential to provide better cancer care to patients in both developed and developing countries. However, new medical technology will not be adopted by medical providers unless it addresses a population’s existing needs and end-users’ preferences. The goals of our study were to assess primary care providers’ level of awareness, interest, and preferences in using POC cancer screening technology in their practice and to provide guidelines to biomedical engineers for future POC technology development. A total of 350 primary care providers completed a one-time self-administered online survey, which took approximately 10 minutes to complete. A $50 Amazon gift card was given as an honorarium for the first 100 respondents to encourage participation. The description of POC cancer screening technology was provided in the beginning of the survey to ensure all participants had a basic understanding of what constitutes POC technology. More than half of the participants (57%) stated that they heard of the term “POC technology” for the first time when they took the survey. However, almost all of the participants (97%) stated they were either “very interested” (68%) or “somewhat interested” (29%) in using POC cancer screening technology in their practice. Demographic characteristics such as the length of being in the practice of medicine, the percentage of patients on Medicaid, and the average number of patients per day were not shown to be associated with the level of interest in using POC. These data show that there is a great interest in POC cancer screening technology utilization among this population of primary care providers and vast room for future investigations to further understand the interest and preferences in using POC cancer technology in practice. Ensuring that the benefits of new technology outweigh the costs will maximize the likelihood it will be used by medical providers and patients. PMID:26771309

  3. DNA Microarray-Based Screening and Characterization of Traditional Chinese Medicine

    PubMed Central

    Kiyama, Ryoiti

    2017-01-01

    The application of DNA microarray assay (DMA) has entered a new era owing to recent innovations in omics technologies. This review summarizes recent applications of DMA-based gene expression profiling by focusing on the screening and characterization of traditional Chinese medicine. First, herbs, mushrooms, and dietary plants analyzed by DMA along with their effective components and their biological/physiological effects are summarized and discussed by examining their comprehensive list and a list of representative effective chemicals. Second, the mechanisms of action of traditional Chinese medicine are summarized by examining the genes and pathways responsible for the action, the cell functions involved in the action, and the activities found by DMA (silent estrogens). Third, applications of DMA for traditional Chinese medicine are discussed by examining reported examples and new protocols for its use in quality control. Further innovations in the signaling pathway-based evaluation of beneficial effects and the assessment of potential risks of traditional Chinese medicine are expected, just as are observed in other closely related fields, such as the therapeutic, environmental, nutritional, and pharmacological fields. PMID:28146102

  4. Scalable Electrophysiological Investigation of iPS Cell-Derived Cardiomyocytes Obtained by a Lentiviral Purification Strategy.

    PubMed

    Friedrichs, Stephanie; Malan, Daniela; Voss, Yvonne; Sasse, Philipp

    2015-01-08

    Disease-specific induced pluripotent stem (iPS) cells can be generated from patients and differentiated into functional cardiomyocytes for characterization of the disease and for drug screening. In order to obtain pure cardiomyocytes for automated electrophysiological investigation, we here report a novel non-clonal purification strategy by using lentiviral gene transfer of a puromycin resistance gene under the control of a cardiac-specific promoter. We have applied this method to our previous reported wild-type and long QT syndrome 3 (LQTS 3)-specific mouse iPS cells and obtained a pure cardiomyocyte population. These cells were investigated by action potential analysis with manual and automatic planar patch clamp technologies, as well as by recording extracellular field potentials using a microelectrode array system. Action potentials and field potentials showed the characteristic prolongation at low heart rates in LQTS 3-specific, but not in wild-type iPS cell-derived cardiomyocytes. Hence, LQTS 3-specific cardiomyocytes can be purified from iPS cells with a lentiviral strategy, maintain the hallmarks of the LQTS 3 disease and can be used for automated electrophysiological characterization and drug screening.

  5. Surface acoustic wave sensors/gas chromatography; and Low quality natural gas sulfur removal and recovery CNG Claus sulfur recovery process

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klint, B.W.; Dale, P.R.; Stephenson, C.

    This topical report consists of the two titled projects. Surface Acoustic Wave/Gas Chromatography (SAW/GC) provides a cost-effective system for collecting real-time field screening data for characterization of vapor streams contaminated with volatile organic compounds (VOCs). The Model 4100 can be used in a field screening mode to produce chromatograms in 10 seconds. This capability will allow a project manager to make immediate decisions and to avoid the long delays and high costs associated with analysis by off-site analytical laboratories. The Model 4100 is currently under evaluation by the California Environmental Protection Agency Technology Certification Program. Initial certification focuses upon themore » following organics: cis-dichloroethylene, chloroform, carbon tetrachloride, trichlorethylene, tetrachloroethylene, tetrachloroethane, benzene, ethylbenzene, toluene, and o-xylene. In the second study the CNG Claus process is being evaluated for conversion and recovery of elemental sulfur from hydrogen sulfide, especially found in low quality natural gas. This report describes the design, construction and operation of a pilot scale plant built to demonstrate the technical feasibility of the integrated CNG Claus process.« less

  6. Electric Field Screening with Backflow at Pulsar Polar Cap

    NASA Astrophysics Data System (ADS)

    Kisaka, Shota; Asano, Katsuaki; Terasawa, Toshio

    2016-09-01

    Recent γ-ray observations suggest that particle acceleration occurs at the outer region of the pulsar magnetosphere. The magnetic field lines in the outer acceleration region (OAR) are connected to the neutron star surface (NSS). If copious electron-positron pairs are produced near the NSS, such pairs flow into the OAR and screen the electric field there. To activate the OAR, the electromagnetic cascade due to the electric field near the NSS should be suppressed. However, since a return current is expected along the field lines through the OAR, the outflow extracted from the NSS alone cannot screen the electric field just above the NSS. In this paper, we analytically and numerically study the electric field screening at the NSS, taking into account the effects of the backflowing particles from the OAR. In certain limited cases, the electric field is screened without significant pair cascade if only ultra-relativistic particles (γ \\gg 1) flow back to the NSS. On the other hand, if electron-positron pairs with a significant number density and mildly relativistic temperature, expected to distribute in a wide region of the magnetosphere, flow back to the NSS, these particles adjust the current and charge densities so that the electric field can be screened without pair cascade. We obtain the condition needed for the number density of particles to screen the electric field at the NSS. We also find that in the ion-extracted case from the NSS, bunches of particles are ejected to the outer region quasi-periodically, which is a possible mechanism of observed radio emission.

  7. Apparel Research Network (ARN) Apparel Order Processing Module (AOPM). Application Program for Management of Special Measurement Clothing Orders

    DTIC Science & Technology

    1997-09-30

    Screen, abandoning changes. APPAREL ORDER PROCESSING MODULE FIELD USER MANUAL Ordering Official Screens The Ordering Official Screens are provided for...currendy selected Ordering Official will appear on the Ordering Official Information Screen. APPAREL ORDER PROCESSING MODULE FIELD USER MANUAL Ordering Official

  8. The Use of AlphaScreen Technology in HTS: Current Status

    PubMed Central

    Eglen, Richard M; Reisine, Terry; Roby, Philippe; Rouleau, Nathalie; Illy, Chantal; Bossé, Roger; Bielefeld, Martina

    2008-01-01

    AlphaScreen (Amplified Luminescent Proximity Homogeneous Assay Screen) is versatile assay technology developed to measuring analytes using a homogenous protocol. This technology is an example of a bead-based proximity assay and was developed from a diagnostic assay technology known as LOCI (Luminescent Oxygen Channeling Assay). Here, singlet oxygen molecules, generated by high energy irradiation of Donor beads, travel over a constrained distance (approx. 200 nm) to Acceptor beads. This results in excitation of a cascading series of chemical reactions, ultimately causing generation of a chemiluminescent signal. In the past decade, a wide variety of applications has been reported, ranging from detection of analytes involved in cell signaling, including protein:protein, protein:peptide, protein:small molecule or peptide:peptide interactions. Numerous homogeneous HTS-optimized assays have been reported using the approach, including generation of second messengers (such as accumulation of cyclic AMP, cyclic GMP, inositol [1, 4, 5] trisphosphate or phosphorylated ERK) from liganded GPCRs or tyrosine kinase receptors, post-translational modification of proteins (such as proteolytic cleavage, phosphorylation, ubiquination and sumoylation) as well as protein-protein and protein-nucleic acid interactions. Recently, the basic AlphaScreen technology was extended in that the chemistry of the Acceptor bead was modified such that emitted light is more intense and spectrally defined, thereby markedly reducing interference from biological fluid matrices (such as trace hemolysis in serum and plasma). In this format, referred to as AlphaLISA, it provides an alternative technology to classical ELISA assays and is suitable for high throughput automated fluid dispensing and detection systems. Collectively, AlphaScreen and AlphaLISA technologies provide a facile assay platform with which one can quantitate complex cellular processes using simple no-wash microtiter plate based assays. They provide the means by which large compound libraries can be screened in a high throughput fashion at a diverse range of therapeutically important targets, often not readily undertaken using other homogeneous assay technologies. This review assesses the current status of the technology in drug discovery, in general, and high throughput screening (HTS), in particular. PMID:20161822

  9. Development and Implementation of High School Chemistry Modules Using Touch-Screen Technologies

    ERIC Educational Resources Information Center

    Lewis, Maurica S.; Zhao, Jinhui; Montclare, Jin Kim

    2012-01-01

    Technology was employed to motivate and captivate students while enriching their in-class education. An outreach program is described that involved college mentors introducing touch-screen technology into a high school chemistry classroom. Three modules were developed, with two of them specifically tailored to encourage comprehension of molecular…

  10. Improving NASA's technology transfer process through increased screening and evaluation in the information dissemination program

    NASA Technical Reports Server (NTRS)

    Laepple, H.

    1979-01-01

    The current status of NASA's technology transfer system can be improved if the technology transfer process is better understood. This understanding will only be gained if a detailed knowledge about factors generally influencing technology transfer is developed, and particularly those factors affecting technology transfer from government R and D agencies to industry. Secondary utilization of aerospace technology is made more difficult because it depends on a transfer process which crosses established organizational lines of authority and which is outside well understood patterns of technical applications. In the absence of a sound theory about technology transfer and because of the limited capability of government agencies to explore industry's needs, a team approach to screening and evaluation of NASA generated technologies is proposed which calls for NASA, and other organizations of the private and public sectors which influence the transfer of NASA generated technology, to participate in a screening and evaluation process to determine the commercial feasibility of a wide range of technical applications.

  11. The challenge of screen printed Ag metallization on nano-scale poly-silicon passivated contacts for silicon solar cells

    NASA Astrophysics Data System (ADS)

    Jiang, Lin; Song, Lixin; Yan, Li; Becht, Gregory; Zhang, Yi; Hoerteis, Matthias

    2017-08-01

    Passivated contacts can be used to reduce metal-induced recombination for higher energy conversion efficiency for silicon solar cells, and are obtained increasing attentions by PV industries in recent years. The reported thicknesses of passivated contact layers are mostly within tens of nanometer range, and the corresponding metallization methods are realized mainly by plating/evaporation technology. This high cost metallization cannot compete with the screen printing technology, and may affect its market potential comparing with the presently dominant solar cell technology. Very few works have been reported on screen printing metallization on passivated contact solar cells. Hence, there is a rising demand to realize screen printing metallization technology on this topic. In this work, we investigate applying screen printing metallization pastes on poly-silicon passivated contacts. The critical challenge for us is to build low contact resistance that can be competitive to standard technology while restricting the paste penetrations within the thin nano-scale passivated contact layers. The contact resistivity of 1.1mohm-cm2 and the open circuit voltages > 660mV are achieved, and the most appropriate thickness range is estimated to be around 80 150nm.

  12. Validation of the ultrasonographic assessment of the femoral trochlea epiphyseal cartilage in foals at osteochondrosis predilected sites with magnetic resonance imaging and histology.

    PubMed

    Martel, G; Forget, C; Gilbert, G; Richard, H; Moser, T; Olive, J; Laverty, S

    2017-11-01

    Noninvasive imaging tools are needed to screen foal femoropatellar joints to detect subclinical osteochondrosis lesions due to focal failure of endochondral ossification to enhance early management to optimise intrinsic healing events. Recently investigations employing 3T susceptibility-weighted magnetic resonance imaging (3T SWI MRI) and CT have demonstrated their capacity for early osteochondrosis diagnosis, but these technologies are not practical for field screening. We postulate that ultrasonography is a valuable field tool for the detection of subclinical osteochondrosis lesions. The goals were to 1) describe the ultrasonographic features of the femoral trochlea of healthy and osteochondrosis-predisposed neonatal foals, 2) validate the capacity of ultrasound to assess cartilage canal vascular archictecture and the ossification front and 3) evaluate field feasibility in a pilot study. Experimental study. Ultrasonographic evaluation of osteochondrosis predisposed (n = 10) and control (n = 6) femoral trochleas was performed ex vivo and compared with site-matched histological sections and 3T SWI MRI. The articular and epiphyseal cartilage thickness, ossification front indentation and cartilage canal vascular archictecture were assessed at each ROI. Femoral trochleae of foals (n = 3) aged ≈ 1, 3 and 6 months were also evaluated with ultrasonography in field. Ultrasonographic measurements strongly correlated with the histological measurements. There was no difference in the cartilage thickness or ossification front indentation between control and osteochondrosis-predisposed specimens. The cartilage canal vascular archictecture on ultrasonograms corresponded with the vessel pattern observed on site matched histology and 3T SWI MRI. The number of specimens for study was limited and no early osteochondrosis lesions were present within the predilected group, but a field study is now underway. Ultrasonographic examination of the femoral trochlea permitted accurate evaluation of cartilage thickness, cartilage canal vascular archictecture and ossification front indentation in young foals and is a promising, practical tool for screening subclinical osteochondrosis and monitoring and managing lesions at important clinical sites. © 2017 EVJ Ltd.

  13. An oppositely charged insect exclusion screen with gap-free multiple electric fields

    NASA Astrophysics Data System (ADS)

    Matsuda, Yoshinori; Kakutani, Koji; Nonomura, Teruo; Kimbara, Junji; Kusakari, Shin-ichi; Osamura, Kazumi; Toyoda, Hideyoshi

    2012-12-01

    An electric field screen was constructed to examine insect attraction mechanisms in multiple electric fields generated inside the screen. The screen consisted of two parallel insulated conductor wires (ICWs) charged with equal but opposite voltages and two separate grounded nets connected to each other and placed on each side of the ICW layer. Insects released inside the fields were charged either positively or negatively as a result of electricity flow from or to the insect, respectively. The force generated between the charged insects and opposite ICW charges was sufficient to capture all insects.

  14. Transforming Security Screening With Biometrics

    DTIC Science & Technology

    2003-04-09

    prompted the Defense Advanced Research Projects Agency to experiment with facial recognition technology for identification of known terrorists. While DoD...screening of individuals. Facial recognition technology has been tested to some degree for accessing highly sensitive military areas, but not for...the military can implement facial recognition to screen personnel requesting access to bases and stations, DoD is not likely to use biometrics to

  15. Human iPSC-derived cardiomyocytes and tissue engineering strategies for disease modeling and drug screening.

    PubMed

    Smith, Alec S T; Macadangdang, Jesse; Leung, Winnie; Laflamme, Michael A; Kim, Deok-Ho

    Improved methodologies for modeling cardiac disease phenotypes and accurately screening the efficacy and toxicity of potential therapeutic compounds are actively being sought to advance drug development and improve disease modeling capabilities. To that end, much recent effort has been devoted to the development of novel engineered biomimetic cardiac tissue platforms that accurately recapitulate the structure and function of the human myocardium. Within the field of cardiac engineering, induced pluripotent stem cells (iPSCs) are an exciting tool that offer the potential to advance the current state of the art, as they are derived from somatic cells, enabling the development of personalized medical strategies and patient specific disease models. Here we review different aspects of iPSC-based cardiac engineering technologies. We highlight methods for producing iPSC-derived cardiomyocytes (iPSC-CMs) and discuss their application to compound efficacy/toxicity screening and in vitro modeling of prevalent cardiac diseases. Special attention is paid to the application of micro- and nano-engineering techniques for the development of novel iPSC-CM based platforms and their potential to advance current preclinical screening modalities. Published by Elsevier Inc.

  16. Ion-selective gold-thiol film on integrated screen-printed electrodes for analysis of Cu(II) ions.

    PubMed

    Li, Meng; Zhou, Hao; Shi, Lei; Li, Da-Wei; Long, Yi-Tao

    2014-02-07

    A novel type of ion-selective electrode (ISE) was manufactured for detecting trace amounts of Cu(II) ions. The basic substrates of ISE were fabricated using screen-printing technology, which could produce disposable electrodes on a large-scale with good repeatability. Moreover, the printed integrated three-electrode system of ISE could be directly used to read out the open-circuit potentials by a handheld device through a USB port. The ion-selective film was composed of gold nanorods (GNRs) and 6-(bis(pyridin-2-ylmethyl)amino)hexane-1-thiol (compound ), which were layer-by-layer modified on the electrode through an easily controlled self-assembly method. Compound contained the 2,2'-dipyridylamine (dpa) group that could coordinate with Cu(II) ions to form a 2 : 1 complex, therefore the screen-printed ISEs exhibited Nernstian potentiometric responses to Cu(II) ions with a detection limit of 6.3 × 10(-7) mol L(-1) over the range of 1.0 × 10(-6) to 1.0 × 10(-2) mol L(-1). The easily prepared screen-printed ion-selective electrode reported here was appropriate for in field analysis and pollutant detection in remote environments.

  17. Field trials for determining the visible and infrared transmittance of screening smoke

    NASA Astrophysics Data System (ADS)

    Sánchez Oliveros, Carmen; Santa-María Sánchez, Guillermo; Rosique Pérez, Carlos

    2009-09-01

    In order to evaluate the concealment capability of smoke, the Countermeasures Laboratory of the Institute of Technology "Marañosa" (ITM) has done a set of tests for measuring the transmittances of multispectral smoke tins in several bands of the electromagnetic spectrum. The smoke composition based on red phosphorous has been developed and patented by this laboratory as a part of a projectile development. The smoke transmittance was measured by means of thermography as well as spectroradiometry. Black bodies and halogen lamps were used as infrared and visible source of radiation. The measurements were carried out in June of 2008 at the Marañosa field (Spain) with two MWIR cameras, two LWIR cameras, one CCD visible camera, one CVF IR spectroradiometer covering the interval 1.5 to 14 microns and one array silicon based spectroradiometer for the 0.2 to 1.1 μm spectra. The transmittance and dimensions of the smoke screen were characterized in the visible band, MWIR (3 - 5 μm and LWIR (8 - 12 μm) regions. The size of the screen was about 30 meters wide and 5 meters high. The transmittances in the IR bands were about 0.3 and better than 0.1 in the visible one. The screens showed to be effective over the time of persistence for all of the tests. The results obtained from the imaging and non-imaging systems were in good accordance. The meteorological conditions during tests such as the wind speed are determinant for the use of this kind of optical countermeasures.

  18. Resonant nuclear reaction 23Mg (p,γ) 24Al in strongly screening magnetized neutron star crust

    NASA Astrophysics Data System (ADS)

    Liu, Jing-Jing; Liu, Dong-Mei

    2017-12-01

    Based on the relativistic theory of superstrong magnetic fields (SMF), by using three models those of Lai (LD), Fushiki (FGP), and our own (LJ), we investigate the influence of SMFs due to strong electron screening (SES) on the nuclear reaction 23Mg (p,γ) 24Al in magnetars. In a relatively low density environment (e.g., ρ 7<0.01) and 1102), our reaction rates can be 1.58 times and about three orders of magnitude larger than those of FGP and LD, respectively (B 12, ρ 7 are in units of 1012G, 107g cm-3). The significant increase of strong screening rate can imply that more 23Mg will escape from the Ne-Na cycle due to SES in a SMF. As a consequence, the next reaction, 24Al (β+, ν) 24Mg, will produce more 24Mg to participate in the Mg-Al cycle. Thus, it may lead to synthesis of a large amount of A>20 nuclides in magnetars. Supported by National Natural Science Foundation of China (11565020), the Counterpart Foundation of Sanya (2016PT43), the Special Foundation of Science and Technology Cooperation for Advanced Academy and Regional of Sanya (2016YD28), the Scientific Research Starting Foundation for 515 Talented Project of Hainan Tropical Ocean University (RHDRC201701) and the Natural Science Foundation of Hainan Province (114012)

  19. Rapid screening of heavy metals and trace elements in environmental samples using portable X-ray fluorescence spectrometer, A comparative study

    PubMed Central

    McComb, Jacqueline Q.; Rogers, Christian; Han, Fengxiang X.; Tchounwou, Paul B.

    2014-01-01

    With industrialization, great amounts of trace elements and heavy metals have been excavated and released on the surface of the earth and dissipated into the environments. Rapid screening technology for detecting major and trace elements as well as heavy metals in variety of environmental samples is most desired. The objectives of this study were to determine the detection limits, accuracy, repeatability and efficiency of a X-ray fluorescence spectrometer (Niton XRF analyzer) in comparison with the traditional analytical methods, inductively coupled plasma optical emission spectrometer (ICP-OES) and inductively coupled plasma optical emission spectrometer (ICP-MS) in screening of major and trace elements of environmental samples including estuary soils and sediments, contaminated soils, and biological samples. XRF is a fast and non-destructive method in measuring the total concentration of multi--elements simultaneously. Contrary to ICP-OES and ICP-MS, XRF analyzer is characterized by the limited preparation required for solid samples, non-destructive analysis, increased total speed and high throughout, the decreased production of hazardous waste and the low running costs as well as multi-elemental determination and portability in the fields. The current comparative study demonstrates that XRF is a good rapid non-destructive method for contaminated soils, sediments and biological samples containing higher concentrations of major and trace elements. Unfortunately, XRF does not have sensitive detection limits of most major and trace elements as ICP-OES or ICP-MS but it may serve as a rapid screening tool for locating hot spots of uncontaminated field soils and sediments. PMID:25861136

  20. Magnetically Actuated Propellant Orientation, Controlling Fluids in a Low-Gravity Environment

    NASA Technical Reports Server (NTRS)

    Martin, James J.; Holt, James B.

    2000-01-01

    Cryogenic fluid management (CFM) is a technology area common to virtually every space transportation propulsion concept envisioned. Storage, supply, transfer and handling of sub-critical cryogenic fluids are basic capabilities that have long been needed by multiple programs and the need is expected to continue in the future. The use of magnetic fields provides another method, which could replace or augment current/traditional approaches, potentially simplifying vehicle operational constraints. The magnetically actuated propellant orientation (MAPO) program effort focused on the use of magnetic fields to control fluid motion as it relates to positioning (i.e. orientation and acquisition) of a paramagnetic substance such as LO2. Current CFM state- of-the-art systems used to control and acquire propellant in low gravity environments rely on liquid surface tension devices which employ vanes, fine screen mesh channels and baskets. These devices trap and direct propellant to areas where it's needed and have been used routinely with storable (non-cryogenic) propellants. However, almost no data exists r,egarding their operation in cryogenics and the use of such devices confronts designers with a multitude of significant technology issues. Typical problems include a sensitivity to screen dry out (due to thermal loads and pressurant gas) and momentary adverse accelerations (generated from either internal or external sources). Any of these problems can potentially cause the acquisition systems to ingest or develop vapor and fail. The use of lightweight high field strength magnets may offer a valuable means of augmenting traditional systems potentially mitigating or at least easing operational requirements. Two potential uses of magnetic fields include: 1) strategically positioning magnets to keep vent ports clear of liquid (enabling low G vented fill operations), and 2) placing magnets in the center or around the walls of the tank to create an insulating vapor pocket (between the liquid and the tank wall) which could effectively lower heat transfer to the liquid (enabling increased storage time).

  1. Microfluidic tools toward industrial biotechnology.

    PubMed

    Oliveira, Aline F; Pessoa, Amanda C S N; Bastos, Reinaldo G; de la Torre, Lucimara G

    2016-11-01

    Microfluidics is a technology that operates with small amounts of fluids and makes possible the investigation of cells, enzymes, and biomolecules and encapsulation of biocatalysts in a greater variety of conditions than permitted using conventional methods. This review discusses technological possibilities that can be applied in the field of industrial biotechnology, presenting the principal definitions and fundamental aspects of microfluidic parameters to better understand advanced approaches. Specifically, concentration gradient generators, droplet-based microfluidics, and microbioreactors are explored as useful tools that can contribute to industrial biotechnology. These tools present potential applications, inclusive as commercial platforms to optimizing in bioprocesses development as screening cells, encapsulating biocatalysts, and determining critical kinetic parameters. © 2016 American Institute of Chemical Engineers Biotechnol. Prog., 32:1372-1389, 2016. © 2016 American Institute of Chemical Engineers.

  2. Avoidance of an electric field by insects: Fundamental biological phenomenon for an electrostatic pest-exclusion strategy

    NASA Astrophysics Data System (ADS)

    Matsuda, Y.; Nonomura, T.; Kakutani, K.; Kimbara, J.; Osamura, K.; Kusakari, S.; Toyoda, H.

    2015-10-01

    An electric field screen is a physical device used to exclude pest insects from greenhouses and warehouses to protect crop production and storage. The screen consists of iron insulated conductor wires (ICWs) arrayed in parallel and linked to each other, an electrostatic DC voltage generator used to supply a negative charge to the ICWs, and an earthed stainless net placed on one side of the ICW layer. The ICW was negatively charged to polarize the earthed net to create a positive charge on the ICW side surface, and an electric field formed between the opposite charges of the ICW and earthed net. The current study focused on the ability of the screen to repel insects reaching the screen net. This repulsion was a result of the insect's behaviour, i.e., the insects were deterred from entering the electric field of the screen. In fact, when the screen was negatively charged with the appropriate voltages, the insects placed their antennae inside the screen and then flew away without entering. Obviously, the insects recognized the electric field using their antennae and thereby avoided entering. Using a wide range of insects and spiders belonging to different taxonomic groups, we confirmed that the avoidance response to the electric field was common in these animals.

  3. Droplet microfluidic technology for single-cell high-throughput screening.

    PubMed

    Brouzes, Eric; Medkova, Martina; Savenelli, Neal; Marran, Dave; Twardowski, Mariusz; Hutchison, J Brian; Rothberg, Jonathan M; Link, Darren R; Perrimon, Norbert; Samuels, Michael L

    2009-08-25

    We present a droplet-based microfluidic technology that enables high-throughput screening of single mammalian cells. This integrated platform allows for the encapsulation of single cells and reagents in independent aqueous microdroplets (1 pL to 10 nL volumes) dispersed in an immiscible carrier oil and enables the digital manipulation of these reactors at a very high-throughput. Here, we validate a full droplet screening workflow by conducting a droplet-based cytotoxicity screen. To perform this screen, we first developed a droplet viability assay that permits the quantitative scoring of cell viability and growth within intact droplets. Next, we demonstrated the high viability of encapsulated human monocytic U937 cells over a period of 4 days. Finally, we developed an optically-coded droplet library enabling the identification of the droplets composition during the assay read-out. Using the integrated droplet technology, we screened a drug library for its cytotoxic effect against U937 cells. Taken together our droplet microfluidic platform is modular, robust, uses no moving parts, and has a wide range of potential applications including high-throughput single-cell analyses, combinatorial screening, and facilitating small sample analyses.

  4. Beyond Mammography: New Frontiers in Breast Cancer Screening

    PubMed Central

    Drukteinis, Jennifer S.; Mooney, Blaise P.; Flowers, Chris I.; Gatenby, Robert A

    2014-01-01

    Breast cancer screening remains a subject of intense and, at times, passionate debate. Mammography has long been the mainstay of breast cancer detection and is the only screening test proven to reduce mortality. Although it remains the gold standard of breast cancer screening, there is increasing awareness of subpopulations of women for whom mammography has reduced sensitivity. Mammography has also undergone increased scrutiny for false positives and excessive biopsies, which increase radiation dose, cost and patient anxiety. In response to these challenges, new technologies for breast cancer screening have been developed, including; low dose mammography; contrast enhanced mammography, tomosynthesis, automated whole breast ultrasound, molecular imaging and MRI. Here we examine some of the current controversies and promising new technologies that may improve detection of breast cancer both in the general population and in high-risk groups, such as women with dense breasts. We propose that optimal breast cancer screening will ultimately require a personalized approach based on metrics of cancer risk with selective application of specific screening technologies best suited to the individual’s age, risk, and breast density. PMID:23561631

  5. Advances in CRISPR-Cas9 genome engineering: lessons learned from RNA interference

    PubMed Central

    Barrangou, Rodolphe; Birmingham, Amanda; Wiemann, Stefan; Beijersbergen, Roderick L.; Hornung, Veit; Smith, Anja van Brabant

    2015-01-01

    The discovery that the machinery of the Clustered Regularly Interspaced Short Palindromic Repeats (CRISPR)-Cas9 bacterial immune system can be re-purposed to easily create deletions, insertions and replacements in the mammalian genome has revolutionized the field of genome engineering and re-invigorated the field of gene therapy. Many parallels have been drawn between the newly discovered CRISPR-Cas9 system and the RNA interference (RNAi) pathway in terms of their utility for understanding and interrogating gene function in mammalian cells. Given this similarity, the CRISPR-Cas9 field stands to benefit immensely from lessons learned during the development of RNAi technology. We examine how the history of RNAi can inform today's challenges in CRISPR-Cas9 genome engineering such as efficiency, specificity, high-throughput screening and delivery for in vivo and therapeutic applications. PMID:25800748

  6. New technique for installing screen wicking into Inconel 718 heat pipe

    NASA Astrophysics Data System (ADS)

    Giriunas, Julius A.; Watson, Gordon K.; Tower, Leonard K.

    1993-01-01

    The creep behavior of superalloys, including Inconel 718, in the presence of liquid sodium is not yet known. To study this problem, the NASA Lewis Research Center has initiated a program with the Energy Technology Engineering Center (ETEC) of Rockwell International Corporation to fill with sodium and creep-test three small cylindrical heat pipes of Inconel 718 for a period of 1000 hours each. This report documents the design and the construction methods that were used at NASA Lewis to fabricate these heat pipes. Of particular importance in the heat pipe construction was the installation of the screen wicking by using an expandable mandrel and differential thermal expansion. This installation technique differs from anything known to have been reported in the heat pipe literature and may be of interest to other workers in the heat pipe field.

  7. Flue gas conditioning for improved particle collection in electrostatic precipitators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Durham, M.D.

    1992-04-27

    The purpose of this research program is to identify and evaluate a variety of additives capable of increasing particle cohesion which could be used for improving collection efficiency in an ESP. A three-phase screening process will be used to provide the, evaluation of many additives in a logical and cost-effective manner. The three step approach involves the following experimental setups: 1. Provide a preliminary screening in the laboratory by measuring the effects of various conditioning agents on reentrainment of flyash particles in an electric field operating at simulated flue gas conditions. 2. Evaluate the successful additives using a 100 acfmmore » bench-scale ESP operating on actual flue gas. 3. Obtain the data required for scaling up the technology by testing the two or three most promising conditioning agents at the pilot scale.« less

  8. Resonance Raman spectroscopy in malaria research.

    PubMed

    Wood, Bayden R; McNaughton, Don

    2006-10-01

    In recent years, the field of Raman spectroscopy has witnessed a surge in technological development, with the incorporation of ultrasensitive, charge-coupled devices, improved laser sources and precision Rayleigh-filter systems. This has led to the development of sensitive confocal micro-Raman spectrometers and imaging spectrometers that are capable of obtaining high spatial-resolution spectra and images of subcellular components within single living cells. This review reports on the application of resonance micro-Raman spectroscopy to the study of malaria pigment (hemozoin), a by-product of hemoglobin catabolization by the malaria parasite, which is an important target site for antimalarial drugs. The review aims to briefly describe recent studies on the application of this technology, elucidate molecular and electronic properties of the malaria pigment and its synthetic analog beta-hematin, provide insight into the mechanism of hemozoin formation within the food vacuole of the parasite, and comment on developing strategies for using this technology in drug-screening protocols.

  9. [Artificial Intelligence in Drug Discovery].

    PubMed

    Fujiwara, Takeshi; Kamada, Mayumi; Okuno, Yasushi

    2018-04-01

    According to the increase of data generated from analytical instruments, application of artificial intelligence(AI)technology in medical field is indispensable. In particular, practical application of AI technology is strongly required in "genomic medicine" and "genomic drug discovery" that conduct medical practice and novel drug development based on individual genomic information. In our laboratory, we have been developing a database to integrate genome data and clinical information obtained by clinical genome analysis and a computational support system for clinical interpretation of variants using AI. In addition, with the aim of creating new therapeutic targets in genomic drug discovery, we have been also working on the development of a binding affinity prediction system for mutated proteins and drugs by molecular dynamics simulation using supercomputer "Kei". We also have tackled for problems in a drug virtual screening. Our developed AI technology has successfully generated virtual compound library, and deep learning method has enabled us to predict interaction between compound and target protein.

  10. Aptamer-based technology for food analysis.

    PubMed

    Liu, Xiaofei; Zhang, Xuewu

    2015-01-01

    Aptamers are short and functional single-stranded oligonucleotide sequences selected from systematic evolution of ligands by exponential enrichment (SELEX) process, which have the capacity to recognize various classes of target molecules with high affinity and specificity. Various analytical aptamers acquired by SELEX are widely used in many research fields, such as medicine, biology, and chemistry. However, the application of this innovative and emerging technology to food safety is just in infant stage. Food safety plays a very important role in our daily lives because varieties of poisonous and harmful substances in food affect human health. Aptamer technique is promising, which can overcome many disadvantages of existing detection methods in food safety, such as long detection time, low sensitivity, difficult, and expensive antibody preparation. This review provides an overview of various aptamer screening technologies and summarizes the recent applications of aptamers in food safety, and future prospects are also discussed.

  11. Prevention and Early Detection of Occupational Cancers - a View of Information Technology Solutions.

    PubMed

    Davoodi, Somayeh; Safdari, Reza; Ghazisaeidi, Marjan; Mohammadzadeh, Zeinab; Azadmanjir, Zahra

    2015-01-01

    Thousands of people die each year from cancer due to occupational causes. To reduce cancer in workers, preventive strategies should be used in the high-risk workplace. The effective prevention of occupational cancer requires knowledge of carcinogen agents. Like other areas of healthcare industry, occupational health has been affected by information technology solutions to improve prevention, early detection, treatment and finally the efficiency and cost effectiveness of the healthcare system. Information technology solutions are thus an important issue in the healthcare field. Information about occupational cancer in information systems is important for policy makers, managers, physicians, patients and researchers; because examples that include high quality data about occupational cancer patients and occupational cancer causes are able to determine the worker groups which require special attention. As a result exposed workers who are vulnerable can undergo screening and be considered for preventive interventions.

  12. The Evonik-Mainz Eye Care-Study (EMECS): Development of an Expert System for Glaucoma Risk Detection in a Working Population

    PubMed Central

    Wahl, Jochen; Barleon, Lorenz; Morfeld, Peter; Lichtmeß, Andrea; Haas-Brähler, Sibylle; Pfeiffer, Norbert

    2016-01-01

    Purpose To develop an expert system for glaucoma screening in a working population based on a human expert procedure using images of optic nerve head (ONH), visual field (frequency doubling technology, FDT) and intraocular pressure (IOP). Methods 4167 of 13037 (32%) employees between 40 and 65 years of Evonik Industries were screened. An experienced glaucoma expert (JW) assessed papilla parameters and evaluated all individual screening results. His classification into “no glaucoma”, “possible glaucoma” and “probable glaucoma” was defined as “gold standard”. A screening model was developed which was tested versus the gold-standard. This model took into account the assessment of the ONH. Values and relationships of CDR and IOP and the FDT were considered additionally and a glaucoma score was generated. The structure of the screening model was specified a priori whereas values of the parameters were chosen post-hoc to optimize sensitivity and specificity of the algorithm. Simple screening models based on IOP and / or FDT were investigated for comparison. Results 111 persons (2.66%) were classified as glaucoma suspects, thereof 13 (0.31%) as probable and 98 (2.35%) as possible glaucoma suspects by the expert. Re-evaluation by the screening model revealed a sensitivity of 83.8% and a specificity of 99.6% for all glaucoma suspects. The positive predictive value of the model was 80.2%, the negative predictive value 99.6%. Simple screening models showed insufficient diagnostic accuracy. Conclusion Adjustment of ONH and symmetry parameters with respect to excavation and IOP in an expert system produced sufficiently satisfying diagnostic accuracy. This screening model seems to be applicable in such a working population with relatively low age and low glaucoma prevalence. Different experts should validate the model in different populations. PMID:27479301

  13. The Evonik-Mainz Eye Care-Study (EMECS): Development of an Expert System for Glaucoma Risk Detection in a Working Population.

    PubMed

    Wahl, Jochen; Barleon, Lorenz; Morfeld, Peter; Lichtmeß, Andrea; Haas-Brähler, Sibylle; Pfeiffer, Norbert

    2016-01-01

    To develop an expert system for glaucoma screening in a working population based on a human expert procedure using images of optic nerve head (ONH), visual field (frequency doubling technology, FDT) and intraocular pressure (IOP). 4167 of 13037 (32%) employees between 40 and 65 years of Evonik Industries were screened. An experienced glaucoma expert (JW) assessed papilla parameters and evaluated all individual screening results. His classification into "no glaucoma", "possible glaucoma" and "probable glaucoma" was defined as "gold standard". A screening model was developed which was tested versus the gold-standard. This model took into account the assessment of the ONH. Values and relationships of CDR and IOP and the FDT were considered additionally and a glaucoma score was generated. The structure of the screening model was specified a priori whereas values of the parameters were chosen post-hoc to optimize sensitivity and specificity of the algorithm. Simple screening models based on IOP and / or FDT were investigated for comparison. 111 persons (2.66%) were classified as glaucoma suspects, thereof 13 (0.31%) as probable and 98 (2.35%) as possible glaucoma suspects by the expert. Re-evaluation by the screening model revealed a sensitivity of 83.8% and a specificity of 99.6% for all glaucoma suspects. The positive predictive value of the model was 80.2%, the negative predictive value 99.6%. Simple screening models showed insufficient diagnostic accuracy. Adjustment of ONH and symmetry parameters with respect to excavation and IOP in an expert system produced sufficiently satisfying diagnostic accuracy. This screening model seems to be applicable in such a working population with relatively low age and low glaucoma prevalence. Different experts should validate the model in different populations.

  14. New site characterization and monitoring technology

    NASA Astrophysics Data System (ADS)

    Nielsen, Bruce J.; Gillispie, Gregory D.; Bohne, David A.; Lindstrom, David R.

    1995-10-01

    The cost of characterizing and monitoring U.S. government hazardous waste sites could exceed $500 billion utilizing traditional methods and technology. New sensor technologies are being developed to meet the nation's environmental remediation and compliance programs. In 1993, the U.S. Air Force Armstrong Laboratory and Loral Defense System, Eagan (formerly a division of Unisys Corporation) signed a Cooperative Research and Development Agreement (CRDA) to commercialize fiber optic laser-induced fluorescence technology that had been developed with U.S. Air Force funding a North Dakota State University (NDSU). A consortium consisting of the CRDA partners (USAF and Loral), Dakota Technologies Inc., and NDSU submitted a proposal to the advanced Research Projects Agency, Technology Reinvestment Project and won an award to fund the commercialization. The result, the Rapid Optical Screening Tool or ROST is a state-of-the-art laser spectroscopy system for analysis of aromatic hydrocarbon-contaminated soil and groundwater. With ROST, environmental investigators are able to find, classify, and map the distribution of many hazardous chemicals in the field instead of waiting for reports to come back from the analytical laboratory. The research and development program leading to prototype laser spectrometers is summarized along with results from laboratory and field demonstrations illustrating system performance and benefits for site characterization. The technology has recently been demonstrated in Europe in Germany, the Netherlands, France an several sites in the United Kingdom having light, medium, and heavy aromatic hydrocarbon contamination from fuel spills and refinery or chemical plant operations. The use of the ROST system to find hydrocarbon contamination is now being offered as a service by Loral Corporation.

  15. Screens and Displays.

    ERIC Educational Resources Information Center

    Edstrom, Malin

    1987-01-01

    Discusses the characteristics of different computer screen technologies including the possible harmful effects on health of cathode ray tube (CRT) terminals. CRT's are compared to other technologies including liquid crystal displays, plasma displays, electroluminiscence displays, and light emitting diodes. A chart comparing the different…

  16. Fifty years of Brazilian Dental Materials Group: scientific contributions of dental materials field evaluated by systematic review

    PubMed Central

    ROSA, Wellington Luiz de Oliveira; SILVA, Tiago Machado; LIMA, Giana da Silveira; SILVA, Adriana Fernandes; PIVA, Evandro

    2016-01-01

    ABSTRACT Objective A systematic review was conducted to analyze Brazilian scientific and technological production related to the dental materials field over the past 50 years. Material and Methods This study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (Prisma) statement. Searches were performed until December 2014 in six databases: MedLine (PubMed), Scopus, LILACS, IBECS, BBO, and the Cochrane Library. Additionally, the Brazilian patent database (INPI - Instituto Nacional de Propriedade Industrial) was screened in order to get an overview of Brazilian technological development in the dental materials field. Two reviewers independently analyzed the documents. Only studies and patents related to dental materials were included in this review. Data regarding the material category, dental specialty, number of documents and patents, filiation countries, and the number of citations were tabulated and analyzed in Microsoft Office Excel (Microsoft Corporation, Redmond, Washington, United States). Results A total of 115,806 studies and 53 patents were related to dental materials and were included in this review. Brazil had 8% affiliation in studies related to dental materials, and the majority of the papers published were related to dental implants (1,137 papers), synthetic resins (681 papers), dental cements (440 papers), dental alloys (392 papers) and dental adhesives (361 papers). The Brazilian technological development with patented dental materials was smaller than the scientific production. The most patented type of material was dental alloys (11 patents), followed by dental implants (8 patents) and composite resins (7 patents). Conclusions Dental materials science has had a substantial number of records, demonstrating an important presence in scientific and technological development of dentistry. In addition, it is important to approximate the relationship between academia and industry to expand the technological development in countries such as Brazil. PMID:27383712

  17. Fifty years of Brazilian Dental Materials Group: scientific contributions of dental materials field evaluated by systematic review.

    PubMed

    Rosa, Wellington Luiz de Oliveira; Silva, Tiago Machado; Lima, Giana da Silveira; Silva, Adriana Fernandes; Piva, Evandro

    2016-01-01

    A systematic review was conducted to analyze Brazilian scientific and technological production related to the dental materials field over the past 50 years. This study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (Prisma) statement. Searches were performed until December 2014 in six databases: MedLine (PubMed), Scopus, LILACS, IBECS, BBO, and the Cochrane Library. Additionally, the Brazilian patent database (INPI - Instituto Nacional de Propriedade Industrial) was screened in order to get an overview of Brazilian technological development in the dental materials field. Two reviewers independently analyzed the documents. Only studies and patents related to dental materials were included in this review. Data regarding the material category, dental specialty, number of documents and patents, filiation countries, and the number of citations were tabulated and analyzed in Microsoft Office Excel (Microsoft Corporation, Redmond, Washington, United States). A total of 115,806 studies and 53 patents were related to dental materials and were included in this review. Brazil had 8% affiliation in studies related to dental materials, and the majority of the papers published were related to dental implants (1,137 papers), synthetic resins (681 papers), dental cements (440 papers), dental alloys (392 papers) and dental adhesives (361 papers). The Brazilian technological development with patented dental materials was smaller than the scientific production. The most patented type of material was dental alloys (11 patents), followed by dental implants (8 patents) and composite resins (7 patents). Dental materials science has had a substantial number of records, demonstrating an important presence in scientific and technological development of dentistry. In addition, it is important to approximate the relationship between academia and industry to expand the technological development in countries such as Brazil.

  18. Integration of real-time 3D capture, reconstruction, and light-field display

    NASA Astrophysics Data System (ADS)

    Zhang, Zhaoxing; Geng, Zheng; Li, Tuotuo; Pei, Renjing; Liu, Yongchun; Zhang, Xiao

    2015-03-01

    Effective integration of 3D acquisition, reconstruction (modeling) and display technologies into a seamless systems provides augmented experience of visualizing and analyzing real objects and scenes with realistic 3D sensation. Applications can be found in medical imaging, gaming, virtual or augmented reality and hybrid simulations. Although 3D acquisition, reconstruction, and display technologies have gained significant momentum in recent years, there seems a lack of attention on synergistically combining these components into a "end-to-end" 3D visualization system. We designed, built and tested an integrated 3D visualization system that is able to capture in real-time 3D light-field images, perform 3D reconstruction to build 3D model of the objects, and display the 3D model on a large autostereoscopic screen. In this article, we will present our system architecture and component designs, hardware/software implementations, and experimental results. We will elaborate on our recent progress on sparse camera array light-field 3D acquisition, real-time dense 3D reconstruction, and autostereoscopic multi-view 3D display. A prototype is finally presented with test results to illustrate the effectiveness of our proposed integrated 3D visualization system.

  19. Effects of Aging and Domain Knowledge on Usability in Small Screen Devices for Diabetes Patients

    NASA Astrophysics Data System (ADS)

    Calero Valdez, André; Ziefle, Martina; Horstmann, Andreas; Herding, Daniel; Schroeder, Ulrik

    Technology acceptance has become a key concept for the successful rollout of technical devices. Though the concept is intensively studied for nearly 20 years now, still, many open questions remain. This especially applies to technology acceptance of older users, which are known to be very sensitive to suboptimal interfaces and show considerable reservations towards the usage of new technology. Mobile small screen technology increasingly penetrates health care and medical applications. This study investigates impacts of aging, technology expertise and domain knowledge on user interaction using the example of diabetes. For this purpose user effectiveness and efficiency have been measured on a simulated small screen device and related to user characteristics, showing that age and technology expertise have a big impact on usability of the device. Furthermore, impacts of user characteristics and success during the trial on acceptance of the device were surveyed and analyzed.

  20. Digital breast tomosynthesis plus synthesised images versus standard full-field digital mammography in population-based screening (TOSYMA): protocol of a randomised controlled trial.

    PubMed

    Weigel, Stefanie; Gerss, Joachim; Hense, Hans-Werner; Krischke, Miriam; Sommer, Alexander; Czwoydzinski, Jörg; Lenzen, Horst; Kerschke, Laura; Spieker, Karin; Dickmaenken, Stefanie; Baier, Sonja; Urban, Marc; Hecht, Gerold; Heidinger, Oliver; Kieschke, Joachim; Heindel, Walter

    2018-05-14

    Development of digital breast tomosynthesis (DBT) provides a technology that generates three-dimensional data sets, thus reducing the pitfalls of overlapping breast tissue. Observational studies suggest that the combination of two-dimensional (2D) digital mammography and DBT increases diagnostic accuracy. However, because of duplicate exposure, this comes at the cost of an augmented radiation dose. This undesired adverse impact can be avoided by using synthesised 2D images reconstructed from the DBT data (s2D).We designed a diagnostic superiority trial on a high level of evidence with the aim of providing a comparison of screening efficacy parameters resulting from DBT+s2D versus the current screening standard 2D full-field digital mammography (FFDM) in a multicentre and multivendor setting on the basis of the quality-controlled, population-based, biennial mammography screening programme in Germany. 80 000 women in the eligible age 50-69 years attending the routine mammography screening programme and willing to participate in the TOSYMA trial will be assigned by 1:1 randomisation to either the intervention arm (DBT+s2D) or the control arm (FFDM) during a 12-month recruitment period in screening units of North Rhine-Westphalia and Lower Saxony. State cancer registries will provide the follow-up of interval cancers.Primary endpoints are the detection rate of invasive breast cancers at screening examination and the cumulative incidence of interval cancers in the 2 years after a negative examination. Secondary endpoints are the detection rate of ductal carcinoma in situ and of tumour size T1, the recall rate for assessment, the positive predictive value of recall and the cumulative 12-month incidence of interval cancers. An adaptive statistical design with one interim analysis provides the option to modify the design. This protocol has been approved by the local medical ethical committee (2016-132-f-S). Results will be submitted to international peer-reviewed journals. NCT03377036; Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. Design of belt conveyor electric control device based on CC-link bus

    NASA Astrophysics Data System (ADS)

    Chen, Goufen; Zhan, Minhua; Li, Jiehua

    2016-01-01

    In view of problem of the existing coal mine belt conveyor is no field bus communication function, two levels belt conveyor electric control system design is proposed based on field bus. Two-stage belt conveyor electric control system consists of operation platform, PLC control unit, various sensors, alarm device and the water spraying device. The error protection is realized by PLC programming, made use of CC-Link bus technology, the data share and the cooperative control came true between host station and slave station. The real-time monitor was achieved by the touch screen program. Practical application shows that the system can ensure the coalmine production, and improve the automatic level of the coalmine transport equipment.

  2. Medical review licensing outcomes in drivers with visual field loss in Victoria, Australia

    PubMed Central

    Muir, Carlyn; Charlton, Judith L; Odell, Morris; Keeffe, Jill; Wood, Joanne; Bohensky, Megan; Fildes, Brian; Oxley, Jennifer; Bentley, Sharon; Rizzo, Matthew

    2017-01-01

    Background Good vision is essential for safe driving and studies have associated visual impairment with an increased crash risk. Currently, there is little information about the medical review of drivers with visual field loss. This study examines the prevalence of visual field loss among drivers referred for medical review in one Australian jurisdiction and investigates factors associated with licence outcome in this group. Methods A random sample of 10,000 (31.25 per cent) medical review cases was extracted for analysis from the Victorian licensing authority. Files were screened for the presence of six visual field-related medical conditions. Data were captured on a range of variables, including referral source, age, gender, health status, crash history and licence outcome. Prevalence analyses were univariate and descriptive. Logistic regression was used to assess factors associated with licence outcomes in the visual field loss group. Results Approximately 1.9 per cent of the 10,000 medical review cases screened had a visual field loss condition identified (n=194). Among the visual field loss group, 57.2 per cent were permitted to continue driving (conditional/unconditional licence). Primary referral sources were the police, self-referrals and general medical practitioners. Key factors associated with licence test outcomes were visual field condition, age group, crash involvement and referral to the Driver Licensing Authority’s Medical Advisors. Those who were younger had a crash involvement triggering referral and those who were referred to the Medical Advisors were more likely to have a positive licensing outcome. Conclusion The evidence base for making licensing decisions is complicated by the variable causes, patterns, progressions and measuring technologies for visual field loss. This study highlighted that the involvement of an expert medical advisory service in Victoria resulted in an increased likelihood that drivers with visual field loss will be allowed to continue driving. Further research is warranted to explore issues relating to severity of field loss and the capacity for compensation. PMID:27530283

  3. Bioreactor Engineering of Stem Cell Environments

    PubMed Central

    Tandon, Nina; Marolt, Darja; Cimetta, Elisa; Vunjak-Novakovic, Gordana

    2013-01-01

    Stem cells hold promise to revolutionize modern medicine by development of new therapies, disease models and drug screening systems. Standard cell culture systems have limited biological relevance because they do not recapitulate the complex 3-dimensional interactions and biophysical cues that characterize the in vivo environment. In this review, we discuss the current advances in engineering stem cell environments using novel biomaterials and bioreactor technologies. We also reflect on the challenges the field is currently facing with regard to translation of stem cell based therapies into the clinic. PMID:23531529

  4. New aspects relating to the behaviour of composites and adhesives in space

    NASA Technical Reports Server (NTRS)

    Carpenter, A.

    1991-01-01

    Some of the specialized testing procedures performed at the JPL Molecular Contamination Investigation Facility for the WideField Planetary Camera II (WFPC II) program for the screening of polymeric materials for outgassing properties are described. For WFPC II, a science performance goal of 1-percent photometric accuracy at 1470 A over an extended time (at least 30 days) has been established. Utilization of the newest technology using CCD detectors poses even more stringent requirements. Test results are presented, and data reduction and modeling techniques are discussed.

  5. Proposed Tier 2 Screening Criteria and Tier 3 Field Procedures for Evaluation of Vapor Intrusion (ESTCP Cost and Performance Report)

    DTIC Science & Technology

    2012-08-01

    Interstate Technology & Regulatory Council, Washington, DC, Copyright 2007. McHugh T.E., D.E. Hammond, T. Nickels , and B. Hartman. 2008. Use of...based corrective action have realized significant cost savings for their corrective action programs (Connor and McHugh , 2002). As described above...Groundwater (Tier 2) VOCs USEPA 8260B 40 mL VOA vial HCl 14 days Vapor (Tier 2 and Tier 3) Radon McHugh et al., 2008 500 mL Tedlar bag None 14

  6. The clinical benefit and safety of current and future assisted reproductive technology.

    PubMed

    Brown, Rachel; Harper, Joyce

    2012-08-01

    Since the first birth by IVF was achieved in 1978, the techniques involved in assisted reproductive technology have grown at an enormous rate. However, new technology has rarely been robustly validated before clinical use and developing scientific understanding of the available techniques has done little to alter their use. Furthermore, there are inconsistencies in the available clinical studies and endpoints. The benefits of some technologies already established for routine use are currently dubious and there are clear ethical concerns with providing them to patients when their scientific basis is not clear. As the uptake of assisted reproductive technology increases and newer technologies continue to push the boundaries of science, it is important to consider the clinical benefits and safety of all assisted reproductive technologies. This review will discuss aspects of some of the more recent techniques, including sperm DNA-damage tests, intracytoplasmic morphologically selected sperm injection, amino acid and metabolomics profiling, preimplantation genetic screening and time-lapse imaging, and those that may have substantial impacts on the field of reproductive medicine in the future including artificial gametes, ovarian transplantation and gene therapy. Copyright © 2012 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.

  7. Magnetically guided capsule endoscopy.

    PubMed

    Shamsudhin, Naveen; Zverev, Vladimir I; Keller, Henrik; Pane, Salvador; Egolf, Peter W; Nelson, Bradley J; Tishin, Alexander M

    2017-08-01

    Wireless capsule endoscopy (WCE) is a powerful tool for medical screening and diagnosis, where a small capsule is swallowed and moved by means of natural peristalsis and gravity through the human gastrointestinal (GI) tract. The camera-integrated capsule allows for visualization of the small intestine, a region which was previously inaccessible to classical flexible endoscopy. As a diagnostic tool, it allows to localize the sources of bleedings in the middle part of the gastrointestinal tract and to identify diseases, such as inflammatory bowel disease (Crohn's disease), polyposis syndrome, and tumors. The screening and diagnostic efficacy of the WCE, especially in the stomach region, is hampered by a variety of technical challenges like the lack of active capsular position and orientation control. Therapeutic functionality is absent in most commercial capsules, due to constraints in capsular volume and energy storage. The possibility of using body-exogenous magnetic fields to guide, orient, power, and operate the capsule and its mechanisms has led to increasing research in Magnetically Guided Capsule Endoscopy (MGCE). This work shortly reviews the history and state-of-art in WCE technology. It highlights the magnetic technologies for advancing diagnostic and therapeutic functionalities of WCE. Not restricting itself to the GI tract, the review further investigates the technological developments in magnetically guided microrobots that can navigate through the various air- and fluid-filled lumina and cavities in the body for minimally invasive medicine. © 2017 American Association of Physicists in Medicine.

  8. Development of novel vaccines using DNA shuffling and screening strategies.

    PubMed

    Locher, Christopher P; Soong, Nay Wei; Whalen, Robert G; Punnonen, Juha

    2004-02-01

    DNA shuffling and screening technologies recombine and evolve genes in vitro to rapidly obtain molecules with improved biological activity and fitness. In this way, genes from related strains are bred like plants or livestock and their successive progeny are selected. These technologies have also been called molecular breeding-directed molecular evolution. Recent developments in bioinformatics-assisted computer programs have facilitated the design, synthesis and analysis of DNA shuffled libraries of chimeric molecules. New applications in vaccine development are among the key features of DNA shuffling and screening technologies because genes from several strains or antigenic variants of pathogens can be recombined to create novel molecules capable of inducing immune responses that protect against infections by multiple strains of pathogens. In addition, molecules such as co-stimulatory molecules and cytokines have been evolved to have improved T-cell proliferation and cytokine production compared with the wild-type human molecules. These molecules can be used to immunomodulate vaccine responsiveness and have multiple applications in infectious diseases, cancer, allergy and autoimmunity. Moreover, DNA shuffling and screening technologies can facilitate process development of vaccine manufacturing through increased expression of recombinant polypeptides and viruses. Therefore, DNA shuffling and screening technologies can overcome some of the challenges that vaccine development currently faces.

  9. Generalizing Screen Inferiority--Does the Medium, Screen versus Paper, Affect Performance Even with Brief Tasks?

    ERIC Educational Resources Information Center

    Sidi, Yael; Ophir, Yael; Ackerman, Rakefet

    2016-01-01

    Screen inferiority in performance and metacognitive processes has been repeatedly found with text learning. Common explanations for screen inferiority relate to technological and physiological disadvantages associated with extensive reading on screen. However, recent studies point to lesser recruitment of mental effort on screen than on paper.…

  10. Moving beyond Screen Time: Redefining Developmentally Appropriate Technology Use in Early Childhood Education. Policy Brief

    ERIC Educational Resources Information Center

    Daugherty, Lindsay; Dossani, Rafiq; Johnson, Erin-Elizabeth; Wright, Cameron

    2014-01-01

    Conversations about what constitutes "developmentally appropriate" use of technology in early childhood education have, to date, focused largely on a single, blunt measure--screen time--that fails to capture important nuances, such as what type of media a child is accessing and whether technology use is taking place solo or with peers.…

  11. Analytical Validation of a Portable Mass Spectrometer Featuring Interchangeable, Ambient Ionization Sources for High Throughput Forensic Evidence Screening

    NASA Astrophysics Data System (ADS)

    Lawton, Zachary E.; Traub, Angelica; Fatigante, William L.; Mancias, Jose; O'Leary, Adam E.; Hall, Seth E.; Wieland, Jamie R.; Oberacher, Herbert; Gizzi, Michael C.; Mulligan, Christopher C.

    2017-06-01

    Forensic evidentiary backlogs are indicative of the growing need for cost-effective, high-throughput instrumental methods. One such emerging technology that shows high promise in meeting this demand while also allowing on-site forensic investigation is portable mass spectrometric (MS) instrumentation, particularly that which enables the coupling to ambient ionization techniques. While the benefits of rapid, on-site screening of contraband can be anticipated, the inherent legal implications of field-collected data necessitates that the analytical performance of technology employed be commensurate with accepted techniques. To this end, comprehensive analytical validation studies are required before broad incorporation by forensic practitioners can be considered, and are the focus of this work. Pertinent performance characteristics such as throughput, selectivity, accuracy/precision, method robustness, and ruggedness have been investigated. Reliability in the form of false positive/negative response rates is also assessed, examining the effect of variables such as user training and experience level. To provide flexibility toward broad chemical evidence analysis, a suite of rapidly-interchangeable ion sources has been developed and characterized through the analysis of common illicit chemicals and emerging threats like substituted phenethylamines. [Figure not available: see fulltext.

  12. Toward virtual anatomy: a stereoscopic 3-D interactive multimedia computer program for cranial osteology.

    PubMed

    Trelease, R B

    1996-01-01

    Advances in computer visualization and user interface technologies have enabled development of "virtual reality" programs that allow users to perceive and to interact with objects in artificial three-dimensional environments. Such technologies were used to create an image database and program for studying the human skull, a specimen that has become increasingly expensive and scarce. Stereoscopic image pairs of a museum-quality skull were digitized from multiple views. For each view, the stereo pairs were interlaced into a single, field-sequential stereoscopic picture using an image processing program. The resulting interlaced image files are organized in an interactive multimedia program. At run-time, gray-scale 3-D images are displayed on a large-screen computer monitor and observed through liquid-crystal shutter goggles. Users can then control the program and change views with a mouse and cursor to point-and-click on screen-level control words ("buttons"). For each view of the skull, an ID control button can be used to overlay pointers and captions for important structures. Pointing and clicking on "hidden buttons" overlying certain structures triggers digitized audio spoken word descriptions or mini lectures.

  13. Smart Screening System (S3) In Taconite Processing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daryoush Allaei; Ryan Wartman; David Tarnowski

    2006-03-01

    The conventional screening machines used in processing plants have had undesirable high noise and vibration levels. They also have had unsatisfactorily low screening efficiency, high energy consumption, high maintenance cost, low productivity, and poor worker safety. These conventional vibrating machines have been used in almost every processing plant. Most of the current material separation technology uses heavy and inefficient electric motors with an unbalanced rotating mass to generate the shaking. In addition to being excessively noisy, inefficient, and high-maintenance, these vibrating machines are often the bottleneck in the entire process. Furthermore, these motors, along with the vibrating machines and supportingmore » structure, shake other machines and structures in the vicinity. The latter increases maintenance costs while reducing worker health and safety. The conventional vibrating fine screens at taconite processing plants have had the same problems as those listed above. This has resulted in lower screening efficiency, higher energy and maintenance cost, and lower productivity and workers safety concerns. The focus of this work is on the design of a high performance screening machine suitable for taconite processing plants. SmartScreens{trademark} technology uses miniaturized motors, based on smart materials, to generate the shaking. The underlying technologies are Energy Flow Control{trademark} and Vibration Control by Confinement{trademark}. These concepts are used to direct energy flow and confine energy efficiently and effectively to the screen function. The SmartScreens{trademark} technology addresses problems related to noise and vibration, screening efficiency, productivity, and maintenance cost and worker safety. Successful development of SmartScreens{trademark} technology will bring drastic changes to the screening and physical separation industry. The final designs for key components of the SmartScreens{trademark} have been developed. The key components include smart motor and associated electronics, resonators, and supporting structural elements. It is shown that the smart motors have an acceptable life and performance. Resonator (or motion amplifier) designs are selected based on the final system requirement and vibration characteristics. All the components for a fully functional prototype are fabricated. The development program is on schedule. The last semi-annual report described the completion of the design refinement phase. This phase resulted in a Smart Screen design that meets performance targets both in the dry condition and with taconite slurry flow using PZT motors. This system was successfully demonstrated for the DOE and partner companies at the Coleraine Mineral Research Laboratory in Coleraine, Minnesota. Since then, the fabrication of the dry application prototype (incorporating an electromagnetic drive mechanism and a new deblinding concept) has been completed and successfully tested at QRDC's lab.« less

  14. Reading on Paper and Screen among Senior Adults: Cognitive Map and Technophobia

    PubMed Central

    Hou, Jinghui; Wu, Yijie; Harrell, Erin

    2017-01-01

    While the senior population has been increasingly engaged with reading on mobile technologies, research that specifically documents the impact of technologies on reading for this age group has still been lacking. The present study investigated how different reading media (screen versus paper) might result in different reading outcomes among older adults due to both cognitive and psychological factors. Using a laboratory experiment with 81participants aged 57 to 85, our results supported past research and showed the influence of cognitive map formation on readers’ feelings of fatigue. We contributed empirical evidence to the contention that reading on a screen could match that of reading from paper if the presentation of the text on screen resemble that of the print. Our findings also suggested that individual levels of technophobia was an important barrier to older adults’ effective use of mobile technologies for reading. In the post hoc analyses, we further showed that technophobia was correlated with technology experience, certain personality traits, and age. The present study highlights the importance of providing tailored support that helps older adults overcome psychological obstacles in using technologies. PMID:29312073

  15. Enhancing Ear and Hearing Health Access for Children With Technology and Connectivity.

    PubMed

    Swanepoel, De Wet

    2017-10-12

    Technology and connectivity advances are demonstrating increasing potential to improve access of service delivery to persons with hearing loss. This article demonstrates use cases from community-based hearing screening and automated diagnosis of ear disease. This brief report reviews recent evidence for school- and home-based hearing testing in underserved communities using smartphone technologies paired with calibrated headphones. Another area of potential impact facilitated by technology and connectivity is the use of feature extraction algorithms to facilitate automated diagnosis of most common ear conditions from video-otoscopic images. Smartphone hearing screening using calibrated headphones demonstrated equivalent sensitivity and specificity for school-based hearing screening. Automating test sequences with a forced-choice response paradigm allowed persons with minimal training to offer screening in underserved communities. The automated image analysis and diagnosis system for ear disease demonstrated an overall accuracy of 80.6%, which is up to par and exceeds accuracy rates previously reported for general practitioners and pediatricians. The emergence of these tools that capitalize on technology and connectivity advances enables affordable and accessible models of service delivery for community-based ear and hearing care.

  16. Confocal nanoscanning, bead picking (CONA): PickoScreen microscopes for automated and quantitative screening of one-bead one-compound libraries.

    PubMed

    Hintersteiner, Martin; Buehler, Christof; Uhl, Volker; Schmied, Mario; Müller, Jürgen; Kottig, Karsten; Auer, Manfred

    2009-01-01

    Solid phase combinatorial chemistry provides fast and cost-effective access to large bead based libraries with compound numbers easily exceeding tens of thousands of compounds. Incubating one-bead one-compound library beads with fluorescently labeled target proteins and identifying and isolating the beads which contain a bound target protein, potentially represents one of the most powerful generic primary high throughput screening formats. On-bead screening (OBS) based on this detection principle can be carried out with limited automation. Often hit bead detection, i.e. recognizing beads with a fluorescently labeled protein bound to the compound on the bead, relies on eye-inspection under a wide-field microscope. Using low resolution detection techniques, the identification of hit beads and their ranking is limited by a low fluorescence signal intensity and varying levels of the library beads' autofluorescence. To exploit the full potential of an OBS process, reliable methods for both automated quantitative detection of hit beads and their subsequent isolation are needed. In a joint collaborative effort with Evotec Technologies (now Perkin-Elmer Cellular Technologies Germany GmbH), we have built two confocal bead scanner and picker platforms PS02 and a high-speed variant PS04 dedicated to automated high resolution OBS. The PS0X instruments combine fully automated confocal large area scanning of a bead monolayer at the bottom of standard MTP plates with semiautomated isolation of individual hit beads via hydraulic-driven picker capillaries. The quantification of fluorescence intensities with high spatial resolution in the equatorial plane of each bead allows for a reliable discrimination between entirely bright autofluorescent beads and real hit beads which exhibit an increased fluorescence signal at the outer few micrometers of the bead. The achieved screening speed of up to 200,000 bead assayed in less than 7 h and the picking time of approximately 1 bead/min allow exploitation of one-bead one-compound libraries with high sensitivity, accuracy, and speed.

  17. CARDIOVASCULAR SCREENING OF YOUNG ATHLETES: A REVIEW OF ECONOMIC EVALUATIONS.

    PubMed

    Gerkens, Sophie; Van Brabandt, Hans; Desomer, Anja; Leonard, Christian; Neyt, Mattias

    2017-01-01

    Some experts have promoted preparticipative cardiovascular screening programs for young athletes and have claimed that such programs were cost-effective without performing a critical analysis of studies supporting this statement. In this systematic review, a critical assessment of economic evaluations on these programs is performed to determine if they really provide value for money. A systematic review of economic evaluations was performed on December 24, 2014. Web sites of health technology assessment agencies, the Cochrane database of systematic review, the National Health Service Economic Evaluation Database of the Cochrane Library, EMBASE, Medline, Psychinfo, and EconLit were searched to retrieve (reviews of) economic evaluations. No language or time restrictions were imposed and predefined selection criteria were used. Selected studies were critically assessed applying a structured data extraction sheet. Five relevant economic evaluations were critically assessed. Results of these studies were mixed. However, those in favor of screening made (methodological) incorrect choices, of which the most important one was not taking into account a no-screening alternative as comparator. Compared with no screening, other strategies (history and physical examination or history and physical examination plus electrocardiogram) were not considered cost-effective. Results of primary economic evaluations should not be blindly copied without critical assessment. Economic evaluations in this field lack the support of robust evidence. Negative consequences of screening (false positive findings, overtreatment) should also be taken into account and may cause more harm than good. A mass screening of young athletes for cardiovascular diseases does not provide value for money and should be discouraged.

  18. Experiences in implementing uHTS--cutting edge technology meets the real world.

    PubMed

    Gribbon, Philip; Schaertl, Sabine; Wickenden, Malcolm; Williams, Gareth; Grimley, Rachel; Stuhmeier, Frank; Preckel, Hartwig; Eggeling, Christian; Kraemer, Joachim; Everett, Jeremy; Keighley, Wilma W; Sewing, Andreas

    2004-01-01

    Driven by growing corporate compound files, the demands of target biology, and attempts to cut cost, the number of solutions to HTS has spiralled. In quick succession new assay technologies and screening platforms are appearing on the market, with the promise of screening faster than ever in low volume high density formats whilst providing high quality data. Within this world of rapid change, Pfizer has applied cutting edge technology to HTS by introducing screening in 1 microl formats utilising single molecule detection technology. Instead of resource intensive in-house development, Pfizer entered into a collaboration with Evotec OAI / Evotec Technologies and introduced their Mark-II EVOscreen platform. In this article we will outline the benefits of the approach taken at Pfizer, Sandwich, and introduce the Mark-II EVOscreen platform, illustrating the potential but also possible pitfalls of HTS miniaturisation.

  19. Moving your laboratories to the field – Advantages and limitations of the use of field portable instruments in environmental sample analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gałuszka, Agnieszka, E-mail: Agnieszka.Galuszka@ujk.edu.pl; Migaszewski, Zdzisław M.; Namieśnik, Jacek

    The recent rapid progress in technology of field portable instruments has increased their applications in environmental sample analysis. These instruments offer a possibility of cost-effective, non-destructive, real-time, direct, on-site measurements of a wide range of both inorganic and organic analytes in gaseous, liquid and solid samples. Some of them do not require the use of reagents and do not produce any analytical waste. All these features contribute to the greenness of field portable techniques. Several stationary analytical instruments have their portable versions. The most popular ones include: gas chromatographs with different detectors (mass spectrometer (MS), flame ionization detector, photoionization detector),more » ultraviolet–visible and near-infrared spectrophotometers, X-ray fluorescence spectrometers, ion mobility spectrometers, electronic noses and electronic tongues. The use of portable instruments in environmental sample analysis gives a possibility of on-site screening and a subsequent selection of samples for routine laboratory analyses. They are also very useful in situations that require an emergency response and for process monitoring applications. However, quantification of results is still problematic in many cases. The other disadvantages include: higher detection limits and lower sensitivity than these obtained in laboratory conditions, a strong influence of environmental factors on the instrument performance and a high possibility of sample contamination in the field. This paper reviews recent applications of field portable instruments in environmental sample analysis and discusses their analytical capabilities. - Highlights: • Field portable instruments are widely used in environmental sample analysis. • Field portable instruments are indispensable for analysis in emergency response. • Miniaturization of field portable instruments reduces resource consumption. • In situ analysis is in agreement with green analytical chemistry principles. • Performance requirements in field analysis stimulate technological progress.« less

  20. PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis.

    PubMed

    Capozzi, Vittorio; Yener, Sine; Khomenko, Iuliia; Farneti, Brian; Cappellin, Luca; Gasperi, Flavia; Scampicchio, Matteo; Biasioli, Franco

    2017-05-11

    Proton Transfer Reaction (PTR), combined with a Time-of-Flight (ToF) Mass Spectrometer (MS) is an analytical approach based on chemical ionization that belongs to the Direct-Injection Mass Spectrometric (DIMS) technologies. These techniques allow the rapid determination of volatile organic compounds (VOCs), assuring high sensitivity and accuracy. In general, PTR-MS requires neither sample preparation nor sample destruction, allowing real time and non-invasive analysis of samples. PTR-MS are exploited in many fields, from environmental and atmospheric chemistry to medical and biological sciences. More recently, we developed a methodology based on coupling PTR-ToF-MS with an automated sampler and tailored data analysis tools, to increase the degree of automation and, consequently, to enhance the potential of the technique. This approach allowed us to monitor bioprocesses (e.g. enzymatic oxidation, alcoholic fermentation), to screen large sample sets (e.g. different origins, entire germoplasms) and to analyze several experimental modes (e.g. different concentrations of a given ingredient, different intensities of a specific technological parameter) in terms of VOC content. Here, we report the experimental protocols exemplifying different possible applications of our methodology: i.e. the detection of VOCs released during lactic acid fermentation of yogurt (on-line bioprocess monitoring), the monitoring of VOCs associated with different apple cultivars (large-scale screening), and the in vivo study of retronasal VOC release during coffee drinking (nosespace analysis).

  1. Newborn Screening for Fragile X Syndrome

    ERIC Educational Resources Information Center

    Bailey, Donald B., Jr.

    2004-01-01

    Newborn screening for fragile X syndrome (FXS) is technically possible, and in the relatively near future accurate and inexpensive screening technologies are likely to be available. When that happens, will America's public health system adopt newborn screening for fragile X syndrome? This article addresses this issue by first placing screening for…

  2. New Technologies in Screening for Disease Risk: Implications for the Worksite and for Health Education.

    ERIC Educational Resources Information Center

    McLeroy, Kenneth R.

    The screening of workers for health problems has been ubiquitous in the worksite for many years. These screening procedures may have ethical and policy implications. Three common types of screening in use include pre-employment, early identification of health problems, and employee monitoring. Pre-employment screening may be used to screen out…

  3. Challenges in profiling and lead optimization of drug discovery for methyltransferases.

    PubMed

    Horiuchi, Kurumi Y

    2015-11-01

    The importance of epigenetics in the initiation and progression of disease has attracted many investigators to incorporate this novel and exciting field in drug development. Protein methyltransferases are one of the target classes which have gained attention as potential therapeutic targets after promising results of inhibitors for EZH2 and DOT1L in clinical trials. There are many technologies developed in order to find small molecule inhibitors for protein methyltransferases. However, in contrast to high throughput screening, profiling against different methyltransferases is challenging since each enzyme has a different substrate preference so that it is hard to profile in one assay format. Here, different technologies for methyltransferase assays will be overviewed, and the advantages and disadvantages of each will be discussed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Bioprinting for cancer research.

    PubMed

    Knowlton, Stephanie; Onal, Sevgi; Yu, Chu Hsiang; Zhao, Jean J; Tasoglu, Savas

    2015-09-01

    Bioprinting offers the ability to create highly complex 3D architectures with living cells. This cutting-edge technique has significantly gained popularity and applicability in several fields. Bioprinting methods have been developed to effectively and rapidly pattern living cells, biological macromolecules, and biomaterials. These technologies hold great potential for applications in cancer research. Bioprinted cancer models represent a significant improvement over previous 2D models by mimicking 3D complexity and facilitating physiologically relevant cell-cell and cell-matrix interactions. Here we review bioprinting methods based on inkjet, microextrusion, and laser technologies and compare 3D cancer models with 2D cancer models. We discuss bioprinted models that mimic the tumor microenvironment, providing a platform for deeper understanding of cancer pathology, anticancer drug screening, and cancer treatment development. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. FUELS IN SOIL TEST KIT: FIELD USE OF DIESEL DOG SOIL TEST KITS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Susan S. Sorini; John F. Schabron; Joseph F. Rovani, Jr.

    Western Research Institute (WRI) has developed a new commercial product ready for technology transfer, the Diesel Dog{reg_sign} Portable Soil Test Kit, for performing analysis of fuel-contaminated soils in the field. The technology consists of a method developed by WRI (U.S. Patents 5,561,065 and 5,976,883) and hardware developed by WRI that allows the method to be performed in the field (patent pending). The method is very simple and does not require the use of highly toxic reagents. The aromatic components in a soil extract are measured by absorption at 254 nm with a field-portable photometer. WRI added significant value to themore » technology by taking the method through the American Society for Testing and Materials (ASTM) approval and validation processes. The method is designated as ASTM Method D 5831-96, Standard Test Method for Screening Fuels in Soils. This ASTM designation allows the method to be used for federal compliance activities. In June 2001, the Diesel Dog technology won an American Chemical Society Regional Industrial Innovations Award. To gain field experience with the new technology, Diesel Dog kits have been used for a variety of site evaluation and cleanup activities. Information gained from these activities has led to improvements in hardware configurations and additional insight into correlating Diesel Dog results with results from laboratory methods. The Wyoming Department of Environmental Quality (DEQ) used Diesel Dog Soil Test Kits to guide cleanups at a variety of sites throughout the state. ENSR, of Acton, Massachusetts, used a Diesel Dog Portable Soil Test Kit to evaluate sites in the Virgin Islands and Georgia. ChemTrack and the U.S. Army Corps of Engineers successfully used a test kit to guide excavation at an abandoned FAA fuel-contaminated site near Fairbanks, Alaska. Barenco, Inc. is using a Diesel Dog Portable Soil Test Kit for site evaluations in Canada. A small spill of diesel fuel was cleaned up in Laramie, Wyoming using a Diesel Dog Soil Test Kit.« less

  6. Fidelity by design: Yoctoreactor and binder trap enrichment for small-molecule DNA-encoded libraries and drug discovery.

    PubMed

    Blakskjaer, Peter; Heitner, Tara; Hansen, Nils Jakob Vest

    2015-06-01

    DNA-encoded small-molecule library (DEL) technology allows vast drug-like small molecule libraries to be efficiently synthesized in a combinatorial fashion and screened in a single tube method for binding, with an assay readout empowered by advances in next generation sequencing technology. This approach has increasingly been applied as a viable technology for the identification of small-molecule modulators to protein targets and as precursors to drugs in the past decade. Several strategies for producing and for screening DELs have been devised by both academic and industrial institutions. This review highlights some of the most significant and recent strategies along with important results. A special focus on the production of high fidelity DEL technologies with the ability to eliminate screening noise and false positives is included: using a DNA junction called the Yoctoreactor, building blocks (BBs) are spatially confined at the center of the junction facilitating both the chemical reaction between BBs and encoding of the synthetic route. A screening method, known as binder trap enrichment, permits DELs to be screened robustly in a homogeneous manner delivering clean data sets and potent hits for even the most challenging targets. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Fragment-based lead generation: identification of seed fragments by a highly efficient fragment screening technology

    NASA Astrophysics Data System (ADS)

    Neumann, Lars; Ritscher, Allegra; Müller, Gerhard; Hafenbradl, Doris

    2009-08-01

    For the detection of the precise and unambiguous binding of fragments to a specific binding site on the target protein, we have developed a novel reporter displacement binding assay technology. The application of this technology for the fragment screening as well as the fragment evolution process with a specific modelling based design strategy is demonstrated for inhibitors of the protein kinase p38alpha. In a fragment screening approach seed fragments were identified which were then used to build compounds from the deep-pocket towards the hinge binding area of the protein kinase p38alpha based on a modelling approach. BIRB796 was used as a blueprint for the alignment of the fragments. The fragment evolution of these deep-pocket binding fragments towards the fully optimized inhibitor BIRB796 included the modulation of the residence time as well as the affinity. The goal of our study was to evaluate the robustness and efficiency of our novel fragment screening technology at high fragment concentrations, compare the screening data with biochemical activity data and to demonstrate the evolution of the hit fragments with fast kinetics, into slow kinetic inhibitors in an in silico approach.

  8. New perspectives in toxicological information management, and the role of ISSTOX databases in assessing chemical mutagenicity and carcinogenicity.

    PubMed

    Benigni, Romualdo; Battistelli, Chiara Laura; Bossa, Cecilia; Tcheremenskaia, Olga; Crettaz, Pierre

    2013-07-01

    Currently, the public has access to a variety of databases containing mutagenicity and carcinogenicity data. These resources are crucial for the toxicologists and regulators involved in the risk assessment of chemicals, which necessitates access to all the relevant literature, and the capability to search across toxicity databases using both biological and chemical criteria. Towards the larger goal of screening chemicals for a wide range of toxicity end points of potential interest, publicly available resources across a large spectrum of biological and chemical data space must be effectively harnessed with current and evolving information technologies (i.e. systematised, integrated and mined), if long-term screening and prediction objectives are to be achieved. A key to rapid progress in the field of chemical toxicity databases is that of combining information technology with the chemical structure as identifier of the molecules. This permits an enormous range of operations (e.g. retrieving chemicals or chemical classes, describing the content of databases, finding similar chemicals, crossing biological and chemical interrogations, etc.) that other more classical databases cannot allow. This article describes the progress in the technology of toxicity databases, including the concepts of Chemical Relational Database and Toxicological Standardized Controlled Vocabularies (Ontology). Then it describes the ISSTOX cluster of toxicological databases at the Istituto Superiore di Sanitá. It consists of freely available databases characterised by the use of modern information technologies and by curation of the quality of the biological data. Finally, this article provides examples of analyses and results made possible by ISSTOX.

  9. Advanced shortwave infrared and Raman hyperspectral sensors for homeland security and law enforcement operations

    NASA Astrophysics Data System (ADS)

    Klueva, Oksana; Nelson, Matthew P.; Gardner, Charles W.; Gomer, Nathaniel R.

    2015-05-01

    Proliferation of chemical and explosive threats as well as illicit drugs continues to be an escalating danger to civilian and military personnel. Conventional means of detecting and identifying hazardous materials often require the use of reagents and/or physical sampling, which is a time-consuming, costly and often dangerous process. Stand-off detection allows the operator to detect threat residues from a safer distance minimizing danger to people and equipment. Current fielded technologies for standoff detection of chemical and explosive threats are challenged by low area search rates, poor targeting efficiency, lack of sensitivity and specificity or use of costly and potentially unsafe equipment such as lasers. A demand exists for stand-off systems that are fast, safe, reliable and user-friendly. To address this need, ChemImage Sensor Systems™ (CISS) has developed reagent-less, non-contact, non-destructive sensors for the real-time detection of hazardous materials based on widefield shortwave infrared (SWIR) and Raman hyperspectral imaging (HSI). Hyperspectral imaging enables automated target detection displayed in the form of image making result analysis intuitive and user-friendly. Application of the CISS' SWIR-HSI and Raman sensing technologies to Homeland Security and Law Enforcement for standoff detection of homemade explosives and illicit drugs and their precursors in vehicle and personnel checkpoints is discussed. Sensing technologies include a portable, robot-mounted and standalone variants of the technology. Test data is shown that supports the use of SWIR and Raman HSI for explosive and drug screening at checkpoints as well as screening for explosives and drugs at suspected clandestine manufacturing facilities.

  10. Hemozoin-generated vapor nanobubbles for transdermal reagent- and needle-free detection of malaria

    PubMed Central

    Lukianova-Hleb, Ekaterina Y.; Campbell, Kelly M.; Constantinou, Pamela E.; Braam, Janet; Olson, John S.; Ware, Russell E.; Sullivan, David J.; Lapotko, Dmitri O.

    2014-01-01

    Successful diagnosis, screening, and elimination of malaria critically depend on rapid and sensitive detection of this dangerous infection, preferably transdermally and without sophisticated reagents or blood drawing. Such diagnostic methods are not currently available. Here we show that the high optical absorbance and nanosize of endogenous heme nanoparticles called “hemozoin,” a unique component of all blood-stage malaria parasites, generates a transient vapor nanobubble around hemozoin in response to a short and safe near-infrared picosecond laser pulse. The acoustic signals of these malaria-specific nanobubbles provided transdermal noninvasive and rapid detection of a malaria infection as low as 0.00034% in animals without using any reagents or drawing blood. These on-demand transient events have no analogs among current malaria markers and probes, can detect and screen malaria in seconds, and can be realized as a compact, easy-to-use, inexpensive, and safe field technology. PMID:24379385

  11. Hemozoin-generated vapor nanobubbles for transdermal reagent- and needle-free detection of malaria.

    PubMed

    Lukianova-Hleb, Ekaterina Y; Campbell, Kelly M; Constantinou, Pamela E; Braam, Janet; Olson, John S; Ware, Russell E; Sullivan, David J; Lapotko, Dmitri O

    2014-01-21

    Successful diagnosis, screening, and elimination of malaria critically depend on rapid and sensitive detection of this dangerous infection, preferably transdermally and without sophisticated reagents or blood drawing. Such diagnostic methods are not currently available. Here we show that the high optical absorbance and nanosize of endogenous heme nanoparticles called "hemozoin," a unique component of all blood-stage malaria parasites, generates a transient vapor nanobubble around hemozoin in response to a short and safe near-infrared picosecond laser pulse. The acoustic signals of these malaria-specific nanobubbles provided transdermal noninvasive and rapid detection of a malaria infection as low as 0.00034% in animals without using any reagents or drawing blood. These on-demand transient events have no analogs among current malaria markers and probes, can detect and screen malaria in seconds, and can be realized as a compact, easy-to-use, inexpensive, and safe field technology.

  12. Optical engineering challenges of the virtual retinal display

    NASA Astrophysics Data System (ADS)

    Kollin, Joel S.; Tidwell, Michael R.

    1995-08-01

    The Virtual Retinal Display (VRD) is a unique approach to developing a high-resolution head- mounted display currently under development at the University of Washington's Human Interface Technology (HIT) Laboratory. Rather than looking at a screen though a magnifier or optical relay system, the viewer of the VRD has a scanned beam of light enter the pupil of the eye and focused to a spot on the retina. This type of optical system is subject to different design constraints than a typical HMD. With the VRD it may be possible to realize higher resolution, greater color saturation, higher brightness and larger field-of-view than a traditional LCD or CRT screen-based system. In this paper the author will present the VRD approach and how it can provide these advantages. Issues to be resolved for the VRD to reach its full potential and some of the solutions developed at the HIT lab will also be discussed.

  13. Computational Screening of 2D Materials for Photocatalysis.

    PubMed

    Singh, Arunima K; Mathew, Kiran; Zhuang, Houlong L; Hennig, Richard G

    2015-03-19

    Two-dimensional (2D) materials exhibit a range of extraordinary electronic, optical, and mechanical properties different from their bulk counterparts with potential applications for 2D materials emerging in energy storage and conversion technologies. In this Perspective, we summarize the recent developments in the field of solar water splitting using 2D materials and review a computational screening approach to rapidly and efficiently discover more 2D materials that possess properties suitable for solar water splitting. Computational tools based on density-functional theory can predict the intrinsic properties of potential photocatalyst such as their electronic properties, optical absorbance, and solubility in aqueous solutions. Computational tools enable the exploration of possible routes to enhance the photocatalytic activity of 2D materials by use of mechanical strain, bias potential, doping, and pH. We discuss future research directions and needed method developments for the computational design and optimization of 2D materials for photocatalysis.

  14. A multi-component nanocomposite screen-printed ink with non-linear touch sensitive electrical conductivity

    NASA Astrophysics Data System (ADS)

    Webb, Alexander J.; Szablewski, Marek; Bloor, David; Atkinson, Del; Graham, Adam; Laughlin, Paul; Lussey, David

    2013-04-01

    Printable electronics is an innovative area of technology with great commercial potential. Here, a screen-printed functional ink, comprising a combination of semiconducting acicular particles, electrically insulating nanoparticles and a base polymer ink, is described that exhibits pronounced pressure sensitive electrical properties for applications in sensing and touch sensitive surfaces. The combination of these components in the as-printed ink yield a complex structure and a large and reproducible touch pressure sensitive resistance range. In contrast to the case for some composite systems, the resistance changes occur down to applied pressures of 13 Pa. Current-voltage measurements at fixed pressures show monotonic non-linear behaviour, which becomes more Ohmic at higher pressures and in all cases shows some hysteresis. The physical basis for conduction, particularly in the low pressure regime, can be described in terms of field assisted quantum mechanical tunnelling.

  15. Scalable Electrophysiological Investigation of iPS Cell-Derived Cardiomyocytes Obtained by a Lentiviral Purification Strategy

    PubMed Central

    Friedrichs, Stephanie; Malan, Daniela; Voss, Yvonne; Sasse, Philipp

    2015-01-01

    Disease-specific induced pluripotent stem (iPS) cells can be generated from patients and differentiated into functional cardiomyocytes for characterization of the disease and for drug screening. In order to obtain pure cardiomyocytes for automated electrophysiological investigation, we here report a novel non-clonal purification strategy by using lentiviral gene transfer of a puromycin resistance gene under the control of a cardiac-specific promoter. We have applied this method to our previous reported wild-type and long QT syndrome 3 (LQTS 3)-specific mouse iPS cells and obtained a pure cardiomyocyte population. These cells were investigated by action potential analysis with manual and automatic planar patch clamp technologies, as well as by recording extracellular field potentials using a microelectrode array system. Action potentials and field potentials showed the characteristic prolongation at low heart rates in LQTS 3-specific, but not in wild-type iPS cell-derived cardiomyocytes. Hence, LQTS 3-specific cardiomyocytes can be purified from iPS cells with a lentiviral strategy, maintain the hallmarks of the LQTS 3 disease and can be used for automated electrophysiological characterization and drug screening. PMID:26237021

  16. Chagas disease drug discovery: toward a new era.

    PubMed

    Chatelain, Eric

    2015-01-01

    American trypanosomiasis, or Chagas disease, is the result of infection by the Trypanosoma cruzi parasite. Endemic in Latin America where it is the major cause of death from cardiomyopathy, the impact of the disease is reaching global proportions through migrating populations. New drugs that are safe, efficacious, low cost, and adapted to the field are critically needed. Over the past five years, there has been increased interest in the disease and a surge in activities within various organizations. However, recent clinical trials with azoles, specifically posaconazole and the ravuconazole prodrug E1224, were disappointing, with treatment failure in Chagas patients reaching 70% to 90%, as opposed to 6% to 30% failure for benznidazole-treated patients. The lack of translation from in vitro and in vivo models to the clinic observed for the azoles raises several questions. There is a scientific requirement to review and challenge whether we are indeed using the right tools and decision-making processes to progress compounds forward for the treatment of this disease. New developments in the Chagas field, including new technologies and tools now available, will be discussed, and a redesign of the current screening strategy during the discovery process is proposed. © 2014 Society for Laboratory Automation and Screening.

  17. Performance characteristics of No-Wall-Losses Hall Thruster

    NASA Astrophysics Data System (ADS)

    Ding, Yongjie; Peng, Wuji; Sun, Hezhi; Wei, Liqiu; Zeng, Ming; Wang, Fufeng; Yu, Daren

    2017-08-01

    A 200 W No-Wall-Losses Hall Thruster (NWLHT-200 W) is designed and processed to verify the technology of pushing down magnetic field with two permanent magnetic rings. To create a magnetic field, NWLHT-200 W uses two permanent magnetic rings (inner and outer) in the absence of magnetic screen or magnetic component. The anode is at the internal magnetic separatrix position, and the thruster shell is hollow to enhance the heat dissipation of ceramics. The magnetic field strength at the channel outlet is 90% of the maximum magnetic field. In this study, the experimental results concerning the thrust, discharge current, specific impulse, and efficiency are presented and examined. Our experiments show that "no erosive discharge" of wall is achieved within the range of 120-460 W; the maximum efficiency of the anode may reach 49%. The thruster designed can work stably for a long time, without any auxiliary heat dissipation equipment (heat pipe or radiator), which significantly prolongs the life of Hall thrusters.

  18. ATHENA, the Desktop Human "Body"

    ScienceCinema

    Iyer, Rashi; Harris, Jennifer

    2018-05-18

    Creating surrogate human organs, coupled with insights from highly sensitive mass spectrometry technologies, a new project is on the brink of revolutionizing the way we screen new drugs and toxic agents. ATHENA, the Advanced Tissue-engineered Human Ectypal Network Analyzer project team, is developing four human organ constructs - liver, heart, lung and kidney - that are based on a significantly miniaturized platform. Each organ component will be about the size of a smartphone screen, and the whole ATHENA "body" of interconnected organs would fit neatly on a desk. "By developing this 'homo minutus,' we are stepping beyond the need for animal or Petri dish testing: There are huge benefits in developing drug and toxicity analysis systems that can mimic the response of actual human organs," said Rashi Iyer, a senior scientist at Los Alamos National Laboratory, the lead laboratory on the five-year, $19 million multi-institutional effort. The project is supported by the Defense Threat Reduction Agency (DTRA). Some 40 percent of pharmaceuticals fail their clinical trials, Iyer noted, and there are thousands of chemicals whose effects on humans are simply unknown. Providing a realistic, cost-effective and rapid screening system such as ATHENA with high-throughput capabilities could provide major benefits to the medical field, screening more accurately and offering a greater chance of clinical trial success.

  19. Screen printed silver top electrode for efficient inverted organic solar cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Junwoo; Duraisamy, Navaneethan; Lee, Taik-Min

    2015-10-15

    Highlights: • Screen printing of silver pattern. • X-ray diffraction pattern confirmed the face centered cubic structure of silver. • Uniform surface morphology of silver pattern with sheet resistance of 0.06 Ω/sq. • The power conversion efficiency of fabricated solar cell is found to be 2.58%. - Abstract: The present work is mainly focused on replacement of the vacuum process for top electrode fabrication in organic solar cells. Silver top electrode deposited through solution based screen printing on pre-deposited polymeric thin film. The solution based printing technology provides uniform top electrode without damaging the underlying organic layers. The surface crystallinitymore » and surface morphology of silver top electrode are examined through X-ray diffraction, field-emission scanning electron microscope and atomic force microscope. The purity of silver is examined through X-ray energy dispersive spectroscopy. The top electrode exhibits face centered cubic structure with homogeneous morphology. The sheet resistance of top electrode is found to be 0.06 Ω/sq and an average pattern thickness of ∼15 μm. The power conversion efficiency is 2.58%. Our work demonstrates that the solution based screen printing is a significant role in the replacement of vacuum process for the fabrication of top electrode in organic solar cells.« less

  20. ATHENA, the Desktop Human "Body"

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iyer, Rashi; Harris, Jennifer

    2014-09-29

    Creating surrogate human organs, coupled with insights from highly sensitive mass spectrometry technologies, a new project is on the brink of revolutionizing the way we screen new drugs and toxic agents. ATHENA, the Advanced Tissue-engineered Human Ectypal Network Analyzer project team, is developing four human organ constructs - liver, heart, lung and kidney - that are based on a significantly miniaturized platform. Each organ component will be about the size of a smartphone screen, and the whole ATHENA "body" of interconnected organs would fit neatly on a desk. "By developing this 'homo minutus,' we are stepping beyond the need formore » animal or Petri dish testing: There are huge benefits in developing drug and toxicity analysis systems that can mimic the response of actual human organs," said Rashi Iyer, a senior scientist at Los Alamos National Laboratory, the lead laboratory on the five-year, $19 million multi-institutional effort. The project is supported by the Defense Threat Reduction Agency (DTRA). Some 40 percent of pharmaceuticals fail their clinical trials, Iyer noted, and there are thousands of chemicals whose effects on humans are simply unknown. Providing a realistic, cost-effective and rapid screening system such as ATHENA with high-throughput capabilities could provide major benefits to the medical field, screening more accurately and offering a greater chance of clinical trial success.« less

  1. Human stem cells and drug screening: opportunities and challenges.

    PubMed

    Ebert, Allison D; Svendsen, Clive N

    2010-05-01

    High-throughput screening technologies are widely used in the early stages of drug discovery to rapidly evaluate the properties of thousands of compounds. However, they generally rely on testing compound libraries on highly proliferative immortalized or cancerous cell lines, which do not necessarily provide an accurate indication of the effects of compounds in normal human cells or the specific cell type under study. Recent advances in stem cell technology have the potential to allow production of a virtually limitless supply of normal human cells that can be differentiated into any specific cell type. Moreover, using induced pluripotent stem cell technology, they can also be generated from patients with specific disease traits, enabling more relevant modelling and drug screens. This article discusses the opportunities and challenges for the use of stem cells in drug screening with a focus on induced pluripotent stem cells.

  2. Genetic screens and functional genomics using CRISPR/Cas9 technology.

    PubMed

    Hartenian, Ella; Doench, John G

    2015-04-01

    Functional genomics attempts to understand the genome by perturbing the flow of information from DNA to RNA to protein, in order to learn how gene dysfunction leads to disease. CRISPR/Cas9 technology is the newest tool in the geneticist's toolbox, allowing researchers to edit DNA with unprecedented ease, speed and accuracy, and representing a novel means to perform genome-wide genetic screens to discover gene function. In this review, we first summarize the discovery and characterization of CRISPR/Cas9, and then compare it to other genome engineering technologies. We discuss its initial use in screening applications, with a focus on optimizing on-target activity and minimizing off-target effects. Finally, we comment on future challenges and opportunities afforded by this technology. © 2015 FEBS.

  3. ALTERNATIVE REMEDIATION TECHNOLOGY STUDY FOR GROUNDWATER TREATMENT AT 200-PO-1 OPERABLE UNIT AT HANFORD SITE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DADO MA

    2008-07-31

    This study focuses on the remediation methods and technologies applicable for use at 200-PO-I Groundwater Operable Unit (OU) at the Hanford Site. The 200-PO-I Groundwater au requires groundwater remediation because of the existence of contaminants of potential concern (COPC). A screening was conducted on alternative technologies and methods of remediation to determine which show the most potential for remediation of groundwater contaminants. The possible technologies were screened to determine which would be suggested for further study and which were not applicable for groundwater remediation. COPCs determined by the Hanford Site groundwater monitoring were grouped into categories based on properties linkingmore » them by remediation methods applicable to each COPC group. The screening considered the following criteria. (1) Determine if the suggested method or technology can be used for the specific contaminants found in groundwater and if the technology can be applied at the 200-PO-I Groundwater au, based on physical characteristics such as geology and depth to groundwater. (2) Evaluate screened technologies based on testing and development stages, effectiveness, implementability, cost, and time. This report documents the results of an intern research project conducted by Mathew Dado for Central Plateau Remediation in the Soil and Groundwater Remediation Project. The study was conducted under the technical supervision of Gloria Cummins and management supervision of Theresa Bergman and Becky Austin.« less

  4. Screening and classification of ceramic powders

    NASA Technical Reports Server (NTRS)

    Miwa, S.

    1983-01-01

    A summary is given of the classification technology of ceramic powders. Advantages and disadvantages of the wet and dry screening and classification methods are discussed. Improvements of wind force screening devices are described.

  5. Microfluidics on liquid handling stations (μF-on-LHS): a new industry-compatible microfluidic platform

    NASA Astrophysics Data System (ADS)

    Kittelmann, Jörg; Radtke, Carsten P.; Waldbaur, Ansgar; Neumann, Christiane; Hubbuch, Jürgen; Rapp, Bastian E.

    2014-03-01

    Since the early days microfluidics as a scientific discipline has been an interdisciplinary research field with a wide scope of potential applications. Besides tailored assays for point-of-care (PoC) diagnostics, microfluidics has been an important tool for large-scale screening of reagents and building blocks in organic chemistry, pharmaceutics and medical engineering. Furthermore, numerous potential marketable products have been described over the years. However, especially in industrial applications, microfluidics is often considered only an alternative technology for fluid handling, a field which is industrially mostly dominated by large-scale numerically controlled fluid and liquid handling stations. Numerous noteworthy products have dominated this field in the last decade and have been inhibited the widespread application of microfluidics technology. However, automated liquid handling stations and microfluidics do not have to be considered as mutually exclusive approached. We have recently introduced a hybrid fluidic platform combining an industrially established liquid handling station and a generic microfluidic interfacing module that allows probing a microfluidic system (such as an essay or a synthesis array) using the instrumentation provided by the liquid handling station. We term this technology "Microfluidic on Liquid Handling Stations (μF-on-LHS)" - a classical "best of both worlds"- approach that allows combining the highly evolved, automated and industry-proven LHS systems with any type of microfluidic assay. In this paper we show, to the best of our knowledge, the first droplet microfluidics application on an industrial LHS using the μF-on-LHS concept.

  6. SeqAPASS to evaluate conservation of high-throughput screening targets across non-mammalian species

    EPA Science Inventory

    Cell-based high-throughput screening (HTS) and computational technologies are being applied as tools for toxicity testing in the 21st century. The U.S. Environmental Protection Agency (EPA) embraced these technologies and created the ToxCast Program in 2007, which has served as a...

  7. An Auto-Tuning PI Control System for an Open-Circuit Low-Speed Wind Tunnel Designed for Greenhouse Technology.

    PubMed

    Espinoza, Karlos; Valera, Diego L; Torres, José A; López, Alejandro; Molina-Aiz, Francisco D

    2015-08-12

    Wind tunnels are a key experimental tool for the analysis of airflow parameters in many fields of application. Despite their great potential impact on agricultural research, few contributions have dealt with the development of automatic control systems for wind tunnels in the field of greenhouse technology. The objective of this paper is to present an automatic control system that provides precision and speed of measurement, as well as efficient data processing in low-speed wind tunnel experiments for greenhouse engineering applications. The system is based on an algorithm that identifies the system model and calculates the optimum PI controller. The validation of the system was performed on a cellulose evaporative cooling pad and on insect-proof screens to assess its response to perturbations. The control system provided an accuracy of <0.06 m·s(-1) for airflow speed and <0.50 Pa for pressure drop, thus permitting the reproducibility and standardization of the tests. The proposed control system also incorporates a fully-integrated software unit that manages the tests in terms of airflow speed and pressure drop set points.

  8. DNA-encoded chemical libraries: advancing beyond conventional small-molecule libraries.

    PubMed

    Franzini, Raphael M; Neri, Dario; Scheuermann, Jörg

    2014-04-15

    DNA-encoded chemical libraries (DECLs) represent a promising tool in drug discovery. DECL technology allows the synthesis and screening of chemical libraries of unprecedented size at moderate costs. In analogy to phage-display technology, where large antibody libraries are displayed on the surface of filamentous phage and are genetically encoded in the phage genome, DECLs feature the display of individual small organic chemical moieties on DNA fragments serving as amplifiable identification barcodes. The DNA-tag facilitates the synthesis and allows the simultaneous screening of very large sets of compounds (up to billions of molecules), because the hit compounds can easily be identified and quantified by PCR-amplification of the DNA-barcode followed by high-throughput DNA sequencing. Several approaches have been used to generate DECLs, differing both in the methods used for library encoding and for the combinatorial assembly of chemical moieties. For example, DECLs can be used for fragment-based drug discovery, displaying a single molecule on DNA or two chemical moieties at the extremities of complementary DNA strands. DECLs can vary substantially in the chemical structures and the library size. While ultralarge libraries containing billions of compounds have been reported containing four or more sets of building blocks, also smaller libraries have been shown to be efficient for ligand discovery. In general, it has been found that the overall library size is a poor predictor for library performance and that the number and diversity of the building blocks are rather important indicators. Smaller libraries consisting of two to three sets of building blocks better fulfill the criteria of drug-likeness and often have higher quality. In this Account, we present advances in the DECL field from proof-of-principle studies to practical applications for drug discovery, both in industry and in academia. DECL technology can yield specific binders to a variety of target proteins and is likely to become a standard tool for pharmaceutical hit discovery, lead expansion, and Chemical Biology research. The introduction of new methodologies for library encoding and for compound synthesis in the presence of DNA is an exciting research field and will crucially contribute to the performance and the propagation of the technology.

  9. A Multiplexed High-Content Screening Approach Using the Chromobody Technology to Identify Cell Cycle Modulators in Living Cells.

    PubMed

    Schorpp, Kenji; Rothenaigner, Ina; Maier, Julia; Traenkle, Bjoern; Rothbauer, Ulrich; Hadian, Kamyar

    2016-10-01

    Many screening hits show relatively poor quality regarding later efficacy and safety. Therefore, small-molecule screening efforts shift toward high-content analysis providing more detailed information. Here, we describe a novel screening approach to identify cell cycle modulators with low toxicity by combining the Cell Cycle Chromobody (CCC) technology with the CytoTox-Glo (CTG) cytotoxicity assay. The CCC technology employs intracellularly functional single-domain antibodies coupled to a fluorescent protein (chromobodies) to visualize the cell cycle-dependent redistribution of the proliferating cell nuclear antigen (PCNA) in living cells. This image-based cell cycle analysis was combined with determination of dead-cell protease activity in cell culture supernatants by the CTG assay. We adopted this multiplex approach to high-throughput format and screened 960 Food and Drug Administration (FDA)-approved drugs. By this, we identified nontoxic compounds, which modulate different cell cycle stages, and validated selected hits in diverse cell lines stably expressing CCC. Additionally, we independently validated these hits by flow cytometry as the current state-of-the-art format for cell cycle analysis. This study demonstrates that CCC imaging is a versatile high-content screening approach to identify cell cycle modulators, which can be multiplexed with cytotoxicity assays for early elimination of toxic compounds during screening. © 2016 Society for Laboratory Automation and Screening.

  10. In vivo robotics: the automation of neuroscience and other intact-system biological fields

    PubMed Central

    Kodandaramaiah, Suhasa B.; Boyden, Edward S.; Forest, Craig R.

    2013-01-01

    Robotic and automation technologies have played a huge role in in vitro biological science, having proved critical for scientific endeavors such as genome sequencing and high-throughput screening. Robotic and automation strategies are beginning to play a greater role in in vivo and in situ sciences, especially when it comes to the difficult in vivo experiments required for understanding the neural mechanisms of behavior and disease. In this perspective, we discuss the prospects for robotics and automation to impact neuroscientific and intact-system biology fields. We discuss how robotic innovations might be created to open up new frontiers in basic and applied neuroscience, and present a concrete example with our recent automation of in vivo whole cell patch clamp electrophysiology of neurons in the living mouse brain. PMID:23841584

  11. Graphene levitation and orientation control using a magnetic field

    NASA Astrophysics Data System (ADS)

    Niu, Chao; Lin, Feng; Wang, Zhiming M.; Bao, Jiming; Hu, Jonathan

    2018-01-01

    This paper studies graphene levitation and orientation control using a magnetic field. The torques in all three spatial directions induced by diamagnetic forces are used to predict stable conditions for different shapes of millimeter-sized graphite plates. We find that graphite plates, in regular polygon shapes with an even number of sides, will be levitated in a stable manner above four interleaved permanent magnets. In addition, the orientation of micrometer-sized graphene flakes near a permanent magnet is studied in both air and liquid environments. Using these analyses, we are able to simulate optical transmission and reflection on a writing board and thereby reveal potential applications using this technology for display screens. Understanding the control of graphene flake orientation will lead to the discovery of future applications using graphene flakes.

  12. Smart Screening System (S3) In Taconite Processing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daryoush Allaei; Angus Morison; David Tarnowski

    2005-09-01

    The conventional screening machines used in processing plants have had undesirable high noise and vibration levels. They also have had unsatisfactorily low screening efficiency, high energy consumption, high maintenance cost, low productivity, and poor worker safety. These conventional vibrating machines have been used in almost every processing plant. Most of the current material separation technology uses heavy and inefficient electric motors with an unbalanced rotating mass to generate the shaking. In addition to being excessively noisy, inefficient, and high-maintenance, these vibrating machines are often the bottleneck in the entire process. Furthermore, these motors, along with the vibrating machines and supportingmore » structure, shake other machines and structures in the vicinity. The latter increases maintenance costs while reducing worker health and safety. The conventional vibrating fine screens at taconite processing plants have had the same problems as those listed above. This has resulted in lower screening efficiency, higher energy and maintenance cost, and lower productivity and workers safety concerns. The focus of this work is on the design of a high performance screening machine suitable for taconite processing plants. SmartScreens{trademark} technology uses miniaturized motors, based on smart materials, to generate the shaking. The underlying technologies are Energy Flow Control{trademark} and Vibration Control by Confinement{trademark}. These concepts are used to direct energy flow and confine energy efficiently and effectively to the screen function. The SmartScreens{trademark} technology addresses problems related to noise and vibration, screening efficiency, productivity, and maintenance cost and worker safety. Successful development of SmartScreens{trademark} technology will bring drastic changes to the screening and physical separation industry. The final designs for key components of the SmartScreens{trademark} have been developed. The key components include smart motor and associated electronics, resonators, and supporting structural elements. It is shown that the smart motors have an acceptable life and performance. Resonator (or motion amplifier) designs are selected based on the final system requirement and vibration characteristics. All the components for a fully functional prototype are fabricated. The development program is on schedule. The last semi-annual report described the process of FE model validation and correlation with experimental data in terms of dynamic performance and predicted stresses. It also detailed efforts into making the supporting structure less important to system performance. Finally, an introduction into the dry application concept was presented. Since then, the design refinement phase was completed. This has resulted in a Smart Screen design that meets performance targets both in the dry condition and with taconite slurry flow using PZT motors. Furthermore, this system was successfully demonstrated for the DOE and partner companies at the Coleraine Mineral Research Laboratory in Coleraine, Minnesota.« less

  13. ICRP Publication 125: Radiological Protection in Security Screening.

    PubMed

    Cool, D A; Lazo, E; Tattersall, P; Simeonov, G; Niu, S

    2014-07-01

    The use of technologies to provide security screening for individuals and objects has been increasing rapidly, in keeping with the significant increase in security concerns worldwide. Within the spectrum of technologies, the use of ionizing radiation to provide backscatter and transmission screening capabilities has also increased. The Commission has previously made a number of statements related to the general topic of deliberate exposures of individuals in non-medical settings. This report provides advice on how the radiological protection principles recommended by the Commission should be applied within the context of security screening. More specifically, the principles of justification, optimisation of protection, and dose limitation for planned exposure situations are directly applicable to the use of ionising radiation in security screening. In addition, several specific topics are considered in this report, including the situation in which individuals may be exposed because they are concealed (‘stowaways’) in a cargo container or conveyance that may be subject to screening. The Commission continues to recommend that careful justification of screening should be considered before decisions are made to employ the technology. If a decision is made that its use is justified, the framework for protection as a planned exposure situation should be employed, including optimization of protection with the use of dose constraints and the appropriate provisions for authorisation and inspection.

  14. Microengineered cell and tissue systems for drug screening and toxicology applications: Evolution of in-vitro liver technologies

    PubMed Central

    Usta, O. B.; McCarty, W. J.; Bale, S.; Hegde, M.; Jindal, R.; Bhushan, A.; Golberg, I.; Yarmush, M. L.

    2015-01-01

    The liver performs many key functions, the most prominent of which is serving as the metabolic hub of the body. For this reason, the liver is the focal point of many investigations aimed at understanding an organism’s toxicological response to endogenous and exogenous challenges. Because so many drug failures have involved direct liver toxicity or other organ toxicity from liver generated metabolites, the pharmaceutical industry has constantly sought superior, predictive in-vitro models that can more quickly and efficiently identify problematic drug candidates before they incur major development costs, and certainly before they are released to the public. In this broad review, we present a survey and critical comparison of in-vitro liver technologies along a broad spectrum, but focus on the current renewed push to develop “organs-on-a-chip”. One prominent set of conclusions from this review is that while a large body of recent work has steered the field towards an ever more comprehensive understanding of what is needed, the field remains in great need of several key advances, including establishment of standard characterization methods, enhanced technologies that mimic the in-vivo cellular environment, and better computational approaches to bridge the gap between the in-vitro and in-vivo results. PMID:26167518

  15. Detecting and removing multiplicative spatial bias in high-throughput screening technologies.

    PubMed

    Caraus, Iurie; Mazoure, Bogdan; Nadon, Robert; Makarenkov, Vladimir

    2017-10-15

    Considerable attention has been paid recently to improve data quality in high-throughput screening (HTS) and high-content screening (HCS) technologies widely used in drug development and chemical toxicity research. However, several environmentally- and procedurally-induced spatial biases in experimental HTS and HCS screens decrease measurement accuracy, leading to increased numbers of false positives and false negatives in hit selection. Although effective bias correction methods and software have been developed over the past decades, almost all of these tools have been designed to reduce the effect of additive bias only. Here, we address the case of multiplicative spatial bias. We introduce three new statistical methods meant to reduce multiplicative spatial bias in screening technologies. We assess the performance of the methods with synthetic and real data affected by multiplicative spatial bias, including comparisons with current bias correction methods. We also describe a wider data correction protocol that integrates methods for removing both assay and plate-specific spatial biases, which can be either additive or multiplicative. The methods for removing multiplicative spatial bias and the data correction protocol are effective in detecting and cleaning experimental data generated by screening technologies. As our protocol is of a general nature, it can be used by researchers analyzing current or next-generation high-throughput screens. The AssayCorrector program, implemented in R, is available on CRAN. makarenkov.vladimir@uqam.ca. Supplementary data are available at Bioinformatics online. © The Author (2017). Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  16. Fluorescence imaging technology (FI) for high-throughput screening of selenide-modified nano-TiO2 catalysts.

    PubMed

    Wang, Liping; Lee, Jianchao; Zhang, Meijuan; Duan, Qiannan; Zhang, Jiarui; Qi, Hailang

    2016-02-18

    A high-throughput screening (HTS) method based on fluorescence imaging (FI) was implemented to evaluate the catalytic performance of selenide-modified nano-TiO2. Chemical ink-jet printing (IJP) technology was reformed to fabricate a catalyst library comprising 1405 (Ni(a)Cu(b)Cd(c)Ce(d)In(e)Y(f))Se(x)/TiO2 (M6Se/Ti) composite photocatalysts. Nineteen M6Se/Tis were screened out from the 1405 candidates efficiently.

  17. iScreen: Image-Based High-Content RNAi Screening Analysis Tools.

    PubMed

    Zhong, Rui; Dong, Xiaonan; Levine, Beth; Xie, Yang; Xiao, Guanghua

    2015-09-01

    High-throughput RNA interference (RNAi) screening has opened up a path to investigating functional genomics in a genome-wide pattern. However, such studies are often restricted to assays that have a single readout format. Recently, advanced image technologies have been coupled with high-throughput RNAi screening to develop high-content screening, in which one or more cell image(s), instead of a single readout, were generated from each well. This image-based high-content screening technology has led to genome-wide functional annotation in a wider spectrum of biological research studies, as well as in drug and target discovery, so that complex cellular phenotypes can be measured in a multiparametric format. Despite these advances, data analysis and visualization tools are still largely lacking for these types of experiments. Therefore, we developed iScreen (image-Based High-content RNAi Screening Analysis Tool), an R package for the statistical modeling and visualization of image-based high-content RNAi screening. Two case studies were used to demonstrate the capability and efficiency of the iScreen package. iScreen is available for download on CRAN (http://cran.cnr.berkeley.edu/web/packages/iScreen/index.html). The user manual is also available as a supplementary document. © 2014 Society for Laboratory Automation and Screening.

  18. Influence of clamping plate permeability and metal screen structures on three-dimensional magnetic field and eddy current loss in end region of a turbo-generator by numerical analysis

    NASA Astrophysics Data System (ADS)

    Likun, Wang; Weili, Li; Yi, Xue; Chunwei, Guan

    2013-11-01

    A significant problem of turbogenerators on complex end structures is overheating of local parts caused by end losses in the end region. Therefore, it is important to investigate the 3-D magnetic field and eddy current loss in the end. In end region of operating large turbogenerator at thermal power plants, magnetic leakage field distribution is complex. In this paper, a 3-D mathematical model used for the calculation of the electromagnetic field in the end region of large turbo-generators is given. The influence of spatial locations of end structures, the actual shape and material of end windings, clamping plate, and copper screen are considered. Adopting the time-step finite element (FE) method and taking the nonlinear characteristics of the core into consideration, a 3-D transient magnetic field is calculated. The objective of this paper is to investigate the influence of clamping plate permeability and metal screen structures on 3-D electromagnetic field distribution and eddy current loss in end region of a turbo-generator. To reduce the temperature of copper screen, a hollow metal screen is proposed. The eddy current loss, which is gained from the 3D transient magnetic field, is used as heat source for the thermal field of end region. The calculated temperatures are compared with test data.

  19. [Antenatal diagnosis: the revolution of new technologies].

    PubMed

    Fokstuen, Siv; Sloan-Béna, Frédérique; lrion, Olivier

    2014-01-15

    Since ten years, the number of amniocenteses or chorionic villous sampling for maternal anxiety has decreased thanks to the first trimester screening of trisomy 21 by ultrasound and maternal serum analysis. Two new tools have recently revolutionized antenatal screening and diagnosis: Analysing fetal DNA in maternal blood for chromosomes 21, 18 and 13 in order to avoid invasive fetal sampling and genomic comparative hybridization in order to diagnose deletions or duplications not detected by conventional caryotyping. These new technologies are dedicated to high-risk pregnancies, and have limitations. They do not replace ultrasound or first trimester screening. Information and ethics are central in antenatal screening and diagnosis.

  20. Ubiquitous Accessibility for People with Visual Impairments: Are We There Yet?

    PubMed Central

    Billah, Syed Masum; Ashok, Vikas; Porter, Donald E.; Ramakrishnan, IV

    2017-01-01

    Ubiquitous access is an increasingly common vision of computing, wherein users can interact with any computing device or service from anywhere, at any time. In the era of personal computing, users with visual impairments required special-purpose, assistive technologies, such as screen readers, to interact with computers. This paper investigates whether technologies like screen readers have kept pace with, or have created a barrier to, the trend toward ubiquitous access, with a specific focus on desktop computing as this is still the primary way computers are used in education and employment. Towards that, the paper presents a user study with 21 visually-impaired participants, specifically involving the switching of screen readers within and across different computing platforms, and the use of screen readers in remote access scenarios. Among the findings, the study shows that, even for remote desktop access—an early forerunner of true ubiquitous access—screen readers are too limited, if not unusable. The study also identifies several accessibility needs, such as uniformity of navigational experience across devices, and recommends potential solutions. In summary, assistive technologies have not made the jump into the era of ubiquitous access, and multiple, inconsistent screen readers create new practical problems for users with visual impairments. PMID:28782061

  1. Ubiquitous Accessibility for People with Visual Impairments: Are We There Yet?

    PubMed

    Billah, Syed Masum; Ashok, Vikas; Porter, Donald E; Ramakrishnan, I V

    2017-05-01

    Ubiquitous access is an increasingly common vision of computing, wherein users can interact with any computing device or service from anywhere, at any time. In the era of personal computing, users with visual impairments required special-purpose, assistive technologies, such as screen readers, to interact with computers. This paper investigates whether technologies like screen readers have kept pace with, or have created a barrier to, the trend toward ubiquitous access, with a specific focus on desktop computing as this is still the primary way computers are used in education and employment. Towards that, the paper presents a user study with 21 visually-impaired participants, specifically involving the switching of screen readers within and across different computing platforms, and the use of screen readers in remote access scenarios. Among the findings, the study shows that, even for remote desktop access-an early forerunner of true ubiquitous access-screen readers are too limited, if not unusable. The study also identifies several accessibility needs, such as uniformity of navigational experience across devices, and recommends potential solutions. In summary, assistive technologies have not made the jump into the era of ubiquitous access, and multiple, inconsistent screen readers create new practical problems for users with visual impairments.

  2. Use of psi(alpha)-ETOs in the unified treatment of electronic attraction, electric field and electric field gradient multicenter integrals of screened Coulomb potentials over Slater orbitals.

    PubMed

    Guseinov, Israfil

    2004-02-01

    In this study, using complete orthonormal sets of Psi(alpha)-ETOs (where alpha=1, 0, -1, -2, ...) introduced by the author, a large number of series expansion formulae for the multicenter electronic attraction (EA), electric field (EF) and electric field gradient (EFG) integrals of the Yukawa-like screened Coulomb potentials (SCPs) is presented through the new central and noncentral potentials and the overlap integrals with the same screening constants. The final results obtained are valid for arbitrary locations of STOs and their parameters.

  3. High-content screening in microfluidic devices.

    PubMed

    Cheong, Raymond; Paliwal, Saurabh; Levchenko, Andre

    2010-08-01

    Miniaturization is the key to advancing the state of the art in high-content screening (HCS) in order to enable dramatic cost savings through reduced usage of expensive biochemical reagents and to enable large-scale screening on primary cells. Microfluidic technology offers the potential to enable HCS to be performed with an unprecedented degree of miniaturization. This perspective highlights a real-world example from the authors’ work of HCS assays implemented in a highly miniaturized microfluidic format. The advantages of this technology are discussed, including cost savings, high-throughput screening on primary cells, improved accuracy, the ability to study complex time-varying stimuli, and ease of automation, integration and scaling. The reader will understand the capabilities of anew microfluidics-based platform for HCS and the advantages it provides over conventional plate-based HCS. Microfluidics technology will drive significant advancements and broader usage and applicability of HCS in drug discovery.

  4. Bioreactor engineering of stem cell environments.

    PubMed

    Tandon, Nina; Marolt, Darja; Cimetta, Elisa; Vunjak-Novakovic, Gordana

    2013-11-15

    Stem cells hold promise to revolutionize modern medicine by the development of new therapies, disease models and drug screening systems. Standard cell culture systems have limited biological relevance because they do not recapitulate the complex 3-dimensional interactions and biophysical cues that characterize the in vivo environment. In this review, we discuss the current advances in engineering stem cell environments using novel biomaterials and bioreactor technologies. We also reflect on the challenges the field is currently facing with regard to the translation of stem cell based therapies into the clinic. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. CRISPR-Cas9 technology: applications and human disease modelling.

    PubMed

    Torres-Ruiz, Raul; Rodriguez-Perales, Sandra

    2017-01-01

    Genome engineering is a powerful tool for a wide range of applications in biomedical research and medicine. The development of the clustered regularly interspaced short palindromic repeats (CRISPR)-Cas9 system has revolutionized the field of gene editing, thus facilitating efficient genome editing through the creation of targeted double-strand breaks of almost any organism and cell type. In addition, CRISPR-Cas9 technology has been used successfully for many other purposes, including regulation of endogenous gene expression, epigenome editing, live-cell labelling of chromosomal loci, edition of single-stranded RNA and high-throughput gene screening. The implementation of the CRISPR-Cas9 system has increased the number of available technological alternatives for studying gene function, thus enabling generation of CRISPR-based disease models. Although many mechanistic questions remain to be answered and several challenges have yet to be addressed, the use of CRISPR-Cas9-based genome engineering technologies will increase our knowledge of disease processes and their treatment in the near future. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  6. Flat panel detectors--closing the (digital) gap in chest and skeletal radiology.

    PubMed

    Reiff, K J

    1999-08-01

    In the radiological department today the majority of all X-ray procedures on chest and skeletal radiography is performed with classical film-screen-systems. Using digital luminescence radiography (DLR or CR, which stands for Computed Radiography) as a technique has shown a way to replace this 100-year-old procedure of doing general radiography work by acquiring the X-rays digitally via phosphor screens, but this approach has faced criticism from lots of radiologists world wide and therefore has not been widely accepted except in the intensive care environment. A new technology is now rising based on the use of so called flat panel X-ray (FD) detectors. Semi-conducting material detects the X-rays in digital form directly and creates an instantaneous image for display, distribution and diagnosis. This ability combined with a large field of view and compared to existing methods--excellent detective quantum efficiency represents a revolutionary step for chest and skeletal radiography and will put basic X-ray-work back into the focus of radiological solutions. This paper will explain the basic technology of flat panel detectors, possible system solutions based on this new technology, aspects of the user interface influencing the system utilization and versatility as well as the possibility to redefine the patient examination process for chest and skeletal radiography. Furthermore the author discusses limitations for the first released systems, upgrades for the installed base and possible scenarios for the future, e.g. fluoroscopy or angiography application.

  7. Army medical laboratory telemedicine: role of mass spectrometry in telediagnosis for chemical and biological defense.

    PubMed

    Smith, J R; Shih, M L; Price, E O; Platoff, G E; Schlager, J J

    2001-12-01

    An army medical field laboratory presently has the capability of performing standard protocols developed at the US Army Medical Research Institute of Chemical Defense for verification of nerve agent or sulfur mustard exposure. The protocols analyze hydrolysis products of chemical warfare agents using gas chromatography/mass spectrometry. Additionally, chemical warfare agents can produce alkylated or phosphorylated proteins following human exposure that have long biological half-lives and can be used as diagnostic biomarkers of chemical agent exposure. An analytical technique known as matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF/MS) currently is being examined for its potential to analyze these biomarkers. The technique is capable of detecting large biomolecules and modifications made to them. Its fast analysis time makes MALDI-TOF/MS technology suitable for screening casualties from chemical or biological attacks. Basic operation requires minimal training and the instrument has the potential to become field-portable. The limitation of the technique is that the generated data may require considerable expertise from knowledgeable personnel for consultation to ensure correct interpretation. The interaction between research scientists and field personnel in the acquisition of data and its interpretation via advanced digital telecommunication technologies can enhance rapid diagnosis and subsequently improve patient care in remote areas. Copyright 2001 John Wiley & Sons, Ltd.

  8. The Role of Retinal Imaging and Portable Screening Devices in Tele-ophthalmology Applications for Diabetic Retinopathy Management.

    PubMed

    DeBuc, Delia Cabrera

    2016-12-01

    In the years since its introduction, retinal imaging has transformed our capability to visualize the posterior pole of the eye. Increasing practical advances in mobile technology, regular monitoring, and population screening for diabetic retinopathy management offer the opportunity for further development of cost-effective applications through remote assessment of the diabetic eye using portable retinal cameras, smart-phone-based devices and telemedicine networks. Numerous retinal imaging methods and mobile technologies in tele-ophthalmology applications have been reported for diabetic retinopathy screening and management. They provide several advantages of automation, sensitivity, specificity, portability, and miniaturization for the development of point-of-care diagnostics for eye complications in diabetes. The aim of this paper is to review the role of retinal imaging and mobile technologies in tele-ophthalmology applications for diabetic retinopathy screening and management. At large, although improvements in current technology and telemedicine services are still needed, telemedicine has demonstrated to be a worthy tool to support health caregivers in the effective management and prevention of diabetes and its complications.

  9. Use of Second Generation Coated Conductors for Efficient Shielding of dc Magnetic Fields (Postprint)

    DTIC Science & Technology

    2010-07-15

    layer of superconducting film, can attenuate an external magnetic field of up to 5 mT by more than an order of magnitude. For comparison purposes...appears to be especially promising for the realization of large scale high-Tc superconducting screens. 15. SUBJECT TERMS magnetic screens, current...realization of large scale high-Tc superconducting screens. © 2010 American Institute of Physics. doi:10.1063/1.3459895 I. INTRODUCTION Magnetic screening

  10. Screening for Human Immunodeficiency Virus, Hepatitis B Virus, Hepatitis C Virus, and Treponema pallidum by Blood Testing Using a Bio-Flash Technology-Based Algorithm before Gastrointestinal Endoscopy

    PubMed Central

    Zhen, Chen; QuiuLi, Zhang; YuanQi, An; Casado, Verónica Vocero; Fan, Yuan

    2016-01-01

    Currently, conventional enzyme immunoassays which use manual gold immunoassays and colloidal tests (GICTs) are used as screening tools to detect Treponema pallidum (syphilis), hepatitis B virus (HBV), hepatitis C virus (HCV), human immunodeficiency virus type 1 (HIV-1), and HIV-2 in patients undergoing surgery. The present observational, cross-sectional study compared the sensitivity, specificity, and work flow characteristics of the conventional algorithm with manual GICTs with those of a newly proposed algorithm that uses the automated Bio-Flash technology as a screening tool in patients undergoing gastrointestinal (GI) endoscopy. A total of 956 patients were examined for the presence of serological markers of infection with HIV-1/2, HCV, HBV, and T. pallidum. The proposed algorithm with the Bio-Flash technology was superior for the detection of all markers (100.0% sensitivity and specificity for detection of anti-HIV and anti-HCV antibodies, HBV surface antigen [HBsAg], and T. pallidum) compared with the conventional algorithm based on the manual method (80.0% sensitivity and 98.6% specificity for the detection of anti-HIV, 75.0% sensitivity for the detection of anti-HCV, 94.7% sensitivity for the detection of HBsAg, and 100% specificity for the detection of anti-HCV and HBsAg) in these patients. The automated Bio-Flash technology-based screening algorithm also reduced the operation time by 85.0% (205 min) per day, saving up to 24 h/week. In conclusion, the use of the newly proposed screening algorithm based on the automated Bio-Flash technology can provide an advantage over the use of conventional algorithms based on manual methods for screening for HIV, HBV, HCV, and syphilis before GI endoscopy. PMID:27707942

  11. Screening for Human Immunodeficiency Virus, Hepatitis B Virus, Hepatitis C Virus, and Treponema pallidum by Blood Testing Using a Bio-Flash Technology-Based Algorithm before Gastrointestinal Endoscopy.

    PubMed

    Jun, Zhou; Zhen, Chen; QuiuLi, Zhang; YuanQi, An; Casado, Verónica Vocero; Fan, Yuan

    2016-12-01

    Currently, conventional enzyme immunoassays which use manual gold immunoassays and colloidal tests (GICTs) are used as screening tools to detect Treponema pallidum (syphilis), hepatitis B virus (HBV), hepatitis C virus (HCV), human immunodeficiency virus type 1 (HIV-1), and HIV-2 in patients undergoing surgery. The present observational, cross-sectional study compared the sensitivity, specificity, and work flow characteristics of the conventional algorithm with manual GICTs with those of a newly proposed algorithm that uses the automated Bio-Flash technology as a screening tool in patients undergoing gastrointestinal (GI) endoscopy. A total of 956 patients were examined for the presence of serological markers of infection with HIV-1/2, HCV, HBV, and T. pallidum The proposed algorithm with the Bio-Flash technology was superior for the detection of all markers (100.0% sensitivity and specificity for detection of anti-HIV and anti-HCV antibodies, HBV surface antigen [HBsAg], and T. pallidum) compared with the conventional algorithm based on the manual method (80.0% sensitivity and 98.6% specificity for the detection of anti-HIV, 75.0% sensitivity for the detection of anti-HCV, 94.7% sensitivity for the detection of HBsAg, and 100% specificity for the detection of anti-HCV and HBsAg) in these patients. The automated Bio-Flash technology-based screening algorithm also reduced the operation time by 85.0% (205 min) per day, saving up to 24 h/week. In conclusion, the use of the newly proposed screening algorithm based on the automated Bio-Flash technology can provide an advantage over the use of conventional algorithms based on manual methods for screening for HIV, HBV, HCV, and syphilis before GI endoscopy. Copyright © 2016 Jun et al.

  12. Towards artificial tissue models: past, present, and future of 3D bioprinting.

    PubMed

    Arslan-Yildiz, Ahu; El Assal, Rami; Chen, Pu; Guven, Sinan; Inci, Fatih; Demirci, Utkan

    2016-03-01

    Regenerative medicine and tissue engineering have seen unprecedented growth in the past decade, driving the field of artificial tissue models towards a revolution in future medicine. Major progress has been achieved through the development of innovative biomanufacturing strategies to pattern and assemble cells and extracellular matrix (ECM) in three-dimensions (3D) to create functional tissue constructs. Bioprinting has emerged as a promising 3D biomanufacturing technology, enabling precise control over spatial and temporal distribution of cells and ECM. Bioprinting technology can be used to engineer artificial tissues and organs by producing scaffolds with controlled spatial heterogeneity of physical properties, cellular composition, and ECM organization. This innovative approach is increasingly utilized in biomedicine, and has potential to create artificial functional constructs for drug screening and toxicology research, as well as tissue and organ transplantation. Herein, we review the recent advances in bioprinting technologies and discuss current markets, approaches, and biomedical applications. We also present current challenges and provide future directions for bioprinting research.

  13. Endovascular repair of aortic disease: a venture capital perspective.

    PubMed

    Buchanan, Lucas W; Stavropoulos, S William; Resnick, Joshua B; Solomon, Jeffrey

    2009-03-01

    Endovascular devices for the treatment of abdominal and thoracic aortic disease are poised to become the next $1 billion medical device market. A shift from open repair to endovascular repair, advances in technology, screening initiatives, and new indications are driving this growth. Although billion-dollar medical device markets are rare, this field is fraught with risk and uncertainty for startups and their venture capital investors. Technological hurdles, daunting clinical and regulatory timelines, market adoption issues, and entrenched competitors pose significant barriers to successful new venture creation. In fact, the number of aortic endografts that have failed to reach commercialization or have been pulled from the market exceeds the number of Food and Drug Administration-approved endografts in the United States. This article will shed some light on the venture capital mind-set and decision-making paradigm in the context of aortic disease.

  14. Screening for Barrett’s Esophagus

    PubMed Central

    di Pietro, Massimiliano; Chan, Daniel; Fitzgerald, Rebecca C.; Wang, Kenneth K.

    2015-01-01

    The large increase in the incidence of esophageal adeno-carcinoma in the West during the past 30 years has stimulated interest in screening for Barrett’s esophagus (BE), a precursor to esophageal cancer. Effective endoscopic treatments for dysplasia and intramucosal cancer, coupled with screening programs to detect BE, could help reverse the increase in the incidence of esophageal cancer. However, there are no accurate, cost-effective, minimally invasive techniques available to screen for BE, reducing the enthusiasm of gastroenterologists. Over the past 5 years, there has been significant progress in the development of screening technologies. We review existing and developing technologies, new minimally invasive imaging techniques, nonendoscopic devices for cell collection, and biomarkers that can be measured in blood or stool samples. We discuss the status of these approaches, data from clinical studies of their effects, and their anticipated strengths and weaknesses in screening. The area is rapidly evolving, and new tools will soon be ready for prime time. PMID:25701083

  15. First clinical trial of the "MiRo" capsule endoscope by using a novel transmission technology: electric-field propagation.

    PubMed

    Bang, Seungmin; Park, Jeong Youp; Jeong, Seok; Kim, Young Ho; Shim, Han Bo; Kim, Tae Song; Lee, Don Haeng; Song, Si Young

    2009-02-01

    We developed a capsule endoscope (CE), "MiRo," with the novel transmission technology of electric-field propagation. The technology uses the human body as a conductive medium for data transmission. Specifications of the prototype include the ability to receive real-time images; size, 10.8 x 24 mm; weight, 3.3 g; field of view, 150 degrees; resolution of power, 320 x 320 pixels; and transmittal speed, 2 frames per second. To evaluate the clinical safety and diagnostic feasibility of the prototype MiRo, we conducted a multicenter clinical trial. All volunteers underwent baseline examinations, including EGD and electrocardiography for the screening of GI obstructive and cardiovascular diseases, before the trial. In the first 10 cases, 24-hour Holter monitoring was also performed. To evaluate the diagnostic feasibility, transmission rate of the captured images, inspection rate of the entire small bowel, and quality of transmitted images (graded as outstanding, excellent, good/average, below average, and poor) were analyzed. Of the 49 healthy volunteers, 45 were included in the trial, and 4 were excluded because of baseline abnormalities. No adverse effects were noted. All CEs were expelled within 2 days, and the entire small bowel could be explored in all cases. The transmission rates of the captured image in the stomach, small bowel, and colon were 99.5%, 99.6%, and 97.2%, respectively. The mean total duration of image transmission was 9 hours, 51 minutes, and the mean transit time of the entire small bowel was 4 hours, 33 minutes. Image quality was graded as good or better in 41 cases (91.1%). Details of the villi and vascular structures of the entire small bowel were clearly visualized in 31 cases (68.9%). MiRo is safe and effective for exploring the entire small bowel, with good image quality and real-time feasibility. This novel transmission technology may have applications beyond the field of capsule endoscopy.

  16. Optical characterization of display screens by speckle patterns

    NASA Astrophysics Data System (ADS)

    Pozo, Antonio M.; Castro, José J.; Rubiño, Manuel

    2013-10-01

    In recent years, flat-panel display (FPD) technology has undergone great development, and now FPDs appear in many devices. A significant element in FPD manufacturing is the display front surface. Manufacturers sell FPDs with different types of front surfaces, which can be matte (also called anti-glare) or glossy screens. Users who prefer glossy screens consider these displays to show more vivid colors compared with matte-screen displays. However, on the glossy screens, external light sources may cause unpleasant reflections that can be reduced by a matte treatment in the front surface. In this work, we present a method to characterize FPD screens using laser-speckle patterns. We characterize three FPDs: a Samsung XL2370 LCD monitor of 23 in. with matte screen, a Toshiba Satellite A100 LCD laptop of 15.4 in. with glossy screen, and a Grammata Papyre 6.1 electronic book reader of 6 in. with ePaper screen (E-ink technology). The results show great differences in speckle-contrast values for the three screens characterized and, therefore, this work shows the feasibility of this method for characterizing and comparing FPDs that have different types of front surfaces.

  17. THE ACCURACY OF DIGITAL-VIDEO RETINAL IMAGING TO SCREEN FOR DIABETIC RETINOPATHY: AN ANALYSIS OF TWO DIGITAL-VIDEO RETINAL IMAGING SYSTEMS USING STANDARD STEREOSCOPIC SEVEN-FIELD PHOTOGRAPHY AND DILATED CLINICAL EXAMINATION AS REFERENCE STANDARDS

    PubMed Central

    Lawrence, Mary Gilbert

    2004-01-01

    ABSTRACT Purpose To evaluate the accuracy of two digital-video retinal imaging (DVRI) systems to detect diabetic retinopathy. Methods A prospective, masked, technology assessment was conducted for two DVRI systems at a tertiary care Veterans Affairs Medical Center. Group A (n = 151 patients) was imaged with a 640 × 480 resolution system and group B (n = 103 patients) with an 800 × 600 resolution system. Four retinal evaluations were performed on each patient: DVRI with undilated pupils using one imaging field (U-DVRI), DVRI with dilated pupils using three imaging fields (D-DVRI), dilated clinical examination, and Early Treatment Diabetic Retinopathy Study stereoscopic seven-field photography (ETDRS-P). Two analyses of accuracy were conducted, one using ETDRS-P as a “gold standard” (ETDRS-GS) and one using dilated clinical examination as a “gold standard” (C-GS). Results For group A, using the ETDRS-GS, sensitivities of U-DVRI and D-DVRI were 0.66 and 0.66; specificities of U-DVRI and D-DVRI were 0.66 and 0.86. Using the C-GS, sensitivities of U-DVRI and D-DVRI were 0.79 and 0.80; specificities of U-DVRI and D-DVRI were 0.68 and 0.85. For group B, using the ETDRS-GS, sensitivities of U-DVRI and D-DVRI were 0.76 and 0.85; specificities of U-DVRI and D-DVRI were 0.45 and 0.80. Using the C-GS, sensitivities of U-DVRI and D-DVRI were 0.81 and 0.87; specificities of U-DVRI and D-DVRI were 0.45 and 0.69. For both groups, dilation significantly improved specificities. Conclusions The 800 × 600 resolution DVRI system offers an accurate method of detecting diabetic retinopathy, provided there is adequate pupillary dilation and three retinal images are taken. DVRI technology may help facilitate retinal screenings of growing diabetic populations. PMID:15747766

  18. “This Lifetime Commitment”: Public Conceptions of Disability and Noninvasive Prenatal Genetic Screening

    PubMed Central

    Steinbach, Rosemary J.; Allyse, Megan; Michie, Marsha; Liu, Emily Y.; Cho, Mildred K.

    2016-01-01

    Recently, new noninvasive prenatal genetic screening technologies for Down syndrome and other genetic conditions have become commercially available. Unique characteristics of these screening tests have reignited long-standing concerns about prenatal testing for intellectual and developmental disabilities. We conducted a web-based survey of a sample of the US public to examine how attitudes towards disability inform views of prenatal testing in the context of these rapidly advancing prenatal genetic screening technologies. Regardless of opinion toward disability, the majority of respondents supported both the availability of screening and the decision to continue a pregnancy positive for aneuploidy. Individuals rationalized their support with various conceptions of disability; complications of the expressivist argument and other concerns from the disability literature were manifested in many responses analyzed. PMID:26566970

  19. SET Careers: An interactive science, engineering, and technology career education exhibit. Final report to the United States Department of Energy Science Museum Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cole, P.R.

    1994-04-01

    The New York Hall of Science in collaboration with the Educational Film Center and the Consortium for Mathematics and its Applications developed and pilot tested a unique interactive, video-based/hypermedia series on energy related and other science and engineering careers for middle and junior high school students. The United States Department of Energy Science Museum Program supported the development of one energy-related career profile (Susan Fancy--mechanical engineer) and the development and printing of 100 copies of a career-related workbook. Additional funding from the National Science Foundation and the Sloan Foundation resulted in the development of 3 additional career profiles, a relatedmore » Data Base and Career Match Self Assessment for 16 careers, available both on screen and in print in this pilot phase. The SET CAREERS Exhibit is a video-based/hypermedia series which contains profiles of people working in Science, Engineering and Technology fields, interactive opportunities for users including interviews with profiled persons, opportunities to attempt work-related tasks through animated simulations, a Data Base of career-related information available both on-screen and in print, and a Career Match Self Assessment. The screen is in an attract loop mode, inviting visitors to interact with the exhibit. A menu of choices is provided so that users may begin by selecting a profiled person, choosing the Career Match Self Assessment or the Data Base. The Data Base is available in print if the user chooses that mode.« less

  20. Pacific Operational Science and Technology Conference

    DTIC Science & Technology

    2008-07-17

    AOR • Think long term-ten to fifty years • Technology assessment • Systems thinking and interaction • Capitalize on technology futures – Renewable ... Renewable energy • Improved mobility • Transportation security • National competitiveness 24 Managed by UT-Battelle for the Department of Energy...Started Cost Schedule Technical TTA CB-034 Tools and Protocols for Agro Screening Ag Screening Tools 500 4,138 3,500 2,500 2,525 3,163 N CB-011 CB-042 Ag

  1. Electrophoretic display technologies for e-book readers: system integration aspects

    NASA Astrophysics Data System (ADS)

    Gentric, Philippe

    2011-03-01

    Emerging screen technologies, such as Electrophoretic Displays (EPD) used in E-book Readers, are changing product power requirements due to their advantageous properties such as bi-stability (effective "zero power" static display) and reflective mode of operation (no backlight). We will first review the emerging screen technologies under the angle of system and IC design impact. We will explain power management consequences for IC design, with a focus on Application Engine SOCs for the wireless/portable markets.

  2. Integrated economic and experimental framework for screening of primary recovery technologies for high cell density CHO cultures

    PubMed Central

    Popova, Daria; Stonier, Adam; Pain, David; Titchener‐Hooker, Nigel J.

    2016-01-01

    Abstract Increases in mammalian cell culture titres and densities have placed significant demands on primary recovery operation performance. This article presents a methodology which aims to screen rapidly and evaluate primary recovery technologies for their scope for technically feasible and cost‐effective operation in the context of high cell density mammalian cell cultures. It was applied to assess the performance of current (centrifugation and depth filtration options) and alternative (tangential flow filtration (TFF)) primary recovery strategies. Cell culture test materials (CCTM) were generated to simulate the most demanding cell culture conditions selected as a screening challenge for the technologies. The performance of these technology options was assessed using lab scale and ultra scale‐down (USD) mimics requiring 25–110mL volumes for centrifugation and depth filtration and TFF screening experiments respectively. A centrifugation and depth filtration combination as well as both of the alternative technologies met the performance selection criteria. A detailed process economics evaluation was carried out at three scales of manufacturing (2,000L, 10,000L, 20,000L), where alternative primary recovery options were shown to potentially provide a more cost‐effective primary recovery process in the future. This assessment process and the study results can aid technology selection to identify the most effective option for a specific scenario. PMID:27067803

  3. [Health technology assessment report: Computer-assisted Pap test for cervical cancer screening].

    PubMed

    Della Palma, Paolo; Moresco, Luca; Giorgi Rossi, Paolo

    2012-01-01

    HEALTH PROBLEM: Cervical cancer is a disease which is highly preventable by means of Pap test screening for the precancerous lesions, which can be easily treated. Furthermore, in the near future, control of the disease will be enhanced by the vaccination which prevents the infection of those human papillomavirus types that cause the vast majority of cervical cancers. The effectiveness of screening in drastically reducing cervical cancer incidence has been clearly demonstrated. The epidemiology of cervical cancer in industrialised countries is now determined mostly by the Pap test coverage of the female population and by the ability of health systems to assure appropriate follow up after an abnormal Pap test. Today there are two fully automated systems for computer-assisted Pap test: the BD FocalPoint and the Hologic Imager. Recently, the Hologic Integrated Imager, a semi-automated system, was launched. The two fully automated systems are composed of a central scanner, where the machine examines the cytologic slide, and of one or more review stations, where the cytologists analyze the slides previously centrally scanned. The softwares used by the two systems identify the fields of interest so that the cytologists can look only at those points, automatically pointed out by the review station. Furthermore, the FocalPoint system classifies the slides according to their level of risk of containing signs of relevant lesions. Those in the upper classes--about one fifth of the slides--are labelled as « further review », while those in the lower level of risk, i.e. slides that have such a low level of risk that they can be considered as negative with no human review, are labelled as « no further review ». The aim of computer-assisted Pap test is to reduce the time of slide examination and to increase productivity. Furthermore, the number of errors due to lack of attention may decrease. Both the systems can be applied to liquidbased cytology, while only the BD Focal Point can be used on conventional smears. Cytology screening has some critical points: there is a shortage of cytologists/cytotechnicians; the quality strongly depends on the experience and ability of the cytologist; there is a subjective component in the cytological diagnosis; in highly screened populations, the prevalence of lesions is very low and the activity of cytologists is very monotonous. On the other hand, a progressive shift to molecular screening using HPV-DNA test as primary screening test is very likely in the near future; cytology will be used as triage test, dramatically reducing the number of slides to process and increasing the prevalence of lesions in those Pap tests. In this Report we assume that the diagnostic accuracy of computer-assisted Pap test is equal to the accuracy of manual Pap test and, consequently, that screening using computer-assisted Pap test has the same efficacy in reducing cervical cancer incidence and mortality. Under this assumption, the effectiveness/ benefit/utility is the same for the two screening modes, i.e. the economic analysis will be a cost minimization study. Furthermore, the screening process is identical for the two modalities in all the phases except for slide interpretation. The cost minimization analysis will be limited to the only phase differing between the two modes, i.e. the study will be a differential cost analysis between a labour-intensive strategy (traditional Pap test) and a technology-intensive strategy (the computer-assisted Pap test). Briefly, the objectives of this HTA Report are: to determine the break even point of computer-assisted Pap test systems, i.e. the volume of slides processed per year at which putting in place a computer-assisted Pap test system becomes economically convenient; to quantify the cost per Pap test in different scenarios according to screening centre activity volume, productivity of cytologist, type of cytology (conventional smear or liquid-based, fully automated or semi-automated computer-assisted); to analyse the computer-assisted Pap test in the Italian context, through a survey of the centres using the technology, collecting data useful for the sensitivity analysis of the economic evaluation; to evaluate the acceptability of the technology in the screening services; to evaluate the organizational and financial impact of the computer-assisted Pap test in different scenarios; to illustrate the ideal organization to implement computer-assisted Pap test in terms of volume of activity, productivity, and human and technological resources. to produce this Report, the following process was adopted: application to the Ministry of health for a grant « Analysis of the impact of professional involvement in evidence generation for the HTA process »; within this project, the sub-project « Cost effectiveness evaluation of the computer-assisted Pap test in the Italian screening programmes » was financed; constitution of the Working Group, which included the project coordinator, the principal investigator, and the health economist; identification of the centres using the computer-assisted Pap test and which had published scientific reports on the subject; identification of the Consulting Committee (stakeholder), which included screening programmes managers, pathologists, economists, health policy-makers, citizen organizations, and manufacturers. Once the evaluation was concluded, a plenary meeting with Working Group and Consulting Committee was held. The working group drafted the final version of this Report, which took into account the comments received. the fully automated computer-assisted Pap test has an important financial and organizational impact on screening programmes. The assessment of this health technology reached the following conclusions: according to the survey results, after some distrust, cytologists accepted the use of the machine and appreciated the reduction in interpretation time and the reliability in identifying the fields of interest; from an economic point of view, the automated computer-assisted Pap test can be convenient only with conventional smears if the screening centre has a volume of more than 49,000 slides/year and the cytologist productivity increases about threefold. It must be highlighted that it is not sufficient to adopt the automated Pap test to reach such an increase in productivity; the laboratory must be organised or re-organised to optimise the use of the review stations and the person time. In the case of liquid-based cytology, the adoption of automated computer- assisted Pap test can only increase the costs. In fact, liquid-based cytology increases the cost of consumable materials but reduces the interpretation time, even in manual screening. Consequently, the reduction of human costs is smaller in the case of computer-assisted screening. Liquid-based cytology has other implications and advantages not linked to the use of computer-assisted Pap test that should be taken into account and are beyond the scope of this Report; given that the computer-assisted Pap test reduces human costs, it may be more advantageous where the cost of cytologists is higher; given the relatively small volume of activity of screening centres in Italy, computer-assisted Pap test may be reasonable for a network using only one central scanner and several remote review stations; the use of automated computer-assisted Pap test only for quality control in a single centre is not economically sustainable. In this case as well, several centres, for example at the regional level, may form a consortium to reach a reasonable number of slides to achieve the break even point. Regarding the use of a machine rather than human intelligence to interpret the slides, some ethical issues were initially raised, but both the scientific community and healthcare professionals have accepted this technology. The identification of fields of interest by the machine is highly reproducible, reducing subjectivity in the diagnostic process. The Hologic system always includes a check by the human eye, while the FocalPoint system identifies about one fifth of the slides as No Further Review. Several studies, some of which conducted in Italy, confirmed the reliability of this classification. There is still some resistance to accept the practice of No Further Review. A check of previous slides and clinical data can be useful to make the cytologist and the clinician more confident. Computer-assisted automated Pap test may be introduced only if there is a need to increase the volume of slides screened to cover the screening target population and sufficient human resources are not available. Switching a programme using conventional slides to automatic scanning can only lead to a reduction in costs if the volume of slides per year exceeds 49,000 slides/annum and cytologist productivity is optimised to more than 20,000 slides per year. At a productivity of 15,000 or fewer, the automated computer-assisted Pap test cannot be convenient. Switching from manual screening with conventional slides to automatic scanning with liquid-based cytology cannot generate any economic saving, but the system could increase output with a given number of staff. The transition from manual to computer assisted automated screening of liquid based cytology will not generate savings and the increase in productivity will be lower than that of the switch from manual/conventional to automated/conventional. The use of biologists or pathologists as cytologists is more costly than the use of cytoscreeners. Given that the automated computer-assisted Pap test reduces human resource costs, its adoption in a model using only biologists and pathologists for screening is more economically advantageous. (ABSTRACT TRUNCATED)

  4. Disease-in-a-dish: the contribution of patient-specific induced pluripotent stem cell technology to regenerative rehabilitation.

    PubMed

    Mack, David L; Guan, Xuan; Wagoner, Ashley; Walker, Stephen J; Childers, Martin K

    2014-11-01

    Advances in regenerative medicine technologies will lead to dramatic changes in how patients in rehabilitation medicine clinics are treated in the upcoming decades. The multidisciplinary field of regenerative medicine is developing new tools for disease modeling and drug discovery based on induced pluripotent stem cells. This approach capitalizes on the idea of personalized medicine by using the patient's own cells to discover new drugs, increasing the likelihood of a favorable outcome. The search for compounds that can correct disease defects in the culture dish is a conceptual departure from how drug screens were done in the past. This system proposes a closed loop from sample collection from the diseased patient, to in vitro disease model, to drug discovery and Food and Drug Administration approval, to delivering that drug back to the same patient. Here, recent progress in patient-specific induced pluripotent stem cell derivation, directed differentiation toward diseased cell types, and how those cells can be used for high-throughput drug screens are reviewed. Given that restoration of normal function is a driving force in rehabilitation medicine, the authors believe that this drug discovery platform focusing on phenotypic rescue will become a key contributor to therapeutic compounds in regenerative rehabilitation.

  5. A Robotic Platform for Quantitative High-Throughput Screening

    PubMed Central

    Michael, Sam; Auld, Douglas; Klumpp, Carleen; Jadhav, Ajit; Zheng, Wei; Thorne, Natasha; Austin, Christopher P.; Inglese, James

    2008-01-01

    Abstract High-throughput screening (HTS) is increasingly being adopted in academic institutions, where the decoupling of screening and drug development has led to unique challenges, as well as novel uses of instrumentation, assay formulations, and software tools. Advances in technology have made automated unattended screening in the 1,536-well plate format broadly accessible and have further facilitated the exploration of new technologies and approaches to screening. A case in point is our recently developed quantitative HTS (qHTS) paradigm, which tests each library compound at multiple concentrations to construct concentration-response curves (CRCs) generating a comprehensive data set for each assay. The practical implementation of qHTS for cell-based and biochemical assays across libraries of > 100,000 compounds (e.g., between 700,000 and 2,000,000 sample wells tested) requires maximal efficiency and miniaturization and the ability to easily accommodate many different assay formats and screening protocols. Here, we describe the design and utilization of a fully integrated and automated screening system for qHTS at the National Institutes of Health's Chemical Genomics Center. We report system productivity, reliability, and flexibility, as well as modifications made to increase throughput, add additional capabilities, and address limitations. The combination of this system and qHTS has led to the generation of over 6 million CRCs from > 120 assays in the last 3 years and is a technology that can be widely implemented to increase efficiency of screening and lead generation. PMID:19035846

  6. Knowledge and social engagement change in intention to be screened for colorectal cancer.

    PubMed

    Molina, Yamile; Briant, Katherine J; Sanchez, Janeth I; O'Connell, Mary A; Thompson, Beti

    2018-07-01

    Innovative technologies have been used to promote colorectal cancer (CRC) screening among the underserved. However, the impact of these innovative technologies on knowledge and social engagement likelihood as they relate to subsequent intention to be screened across different populations has not been fully explored. Using a pre-post-test design with an inflatable walk-through colon, we assessed changes in knowledge and social engagement likelihood across populations and their associations with intention to be screened in two community settings. One was a community setting in Washington State (WA); the other, a college campus in New Mexico (NM). Differential effects on knowledge and social engagement likelihood were examined across demographic groups (race/ethnicity, gender, age, education, insurance status, and geographic region). Finally, we assessed if changes in knowledge and social engagement likelihood were associated with CRC screening intention. NM males had greater gains in CRC knowledge than NM females; in WA, Hispanics, younger, less educated, and uninsured participants had greater gains in knowledge. NM females and younger WA participants were more likely to discuss CRC with their social networks than NM males and older WA participants. In WA, Hispanics and older adults reported greater intention to be screened for CRC. Change in social engagement likelihood, but not knowledge, was associated with intention to be screened. The effectiveness of health promotion technologies on knowledge and social engagement may vary across different demographic characteristics. Further, the importance of social engagement likelihood in interacting with intention to be screened was substantiated.

  7. “I think we’ve got too many tests!”: Prenatal providers’ reflections on ethical and clinical challenges in the practice integration of cell-free DNA screening

    PubMed Central

    Gammon, B.L.; Kraft, S.A.; Michie, M.; Allyse, M.

    2016-01-01

    Background The recent introduction of cell-free DNA-based non-invasive prenatal screening (cfDNA screening) into clinical practice was expected to revolutionize prenatal testing. cfDNA screening for fetal aneuploidy has demonstrated higher test sensitivity and specificity for some conditions than conventional serum screening and can be conducted early in the pregnancy. However, it is not clear whether and how clinical practices are assimilating this new type of testing into their informed consent and counselling processes. Since the introduction of cfDNA screening into practice in 2011, the uptake and scope have increased dramatically. Prenatal care providers are under pressure to stay up to date with rapidly changing cfDNA screening panels, manage increasing patient demands, and keep up with changing test costs, all while attempting to use the technology responsibly and ethically. While clinical literature on cfDNA screening has shown benefits for specific patient populations, it has also identified significant misunderstandings among providers and patients alike about the power of the technology. The unique features of cfDNA screening, in comparison to established prenatal testing technologies, have implications for informed decision-making and genetic counselling that must be addressed to ensure ethical practice. Objectives This study explored the experiences of prenatal care providers at the forefront of non-invasive genetic screening in the United States to understand how this testing changes the practice of prenatal medicine. We aimed to learn how the experience of providing and offering this testing differs from established prenatal testing methodologies. These differences may necessitate changes to patient education and consent procedures to maintain ethical practice. Methods We used the online American Congress of Obstetricians and Gynecologists Physician Directory to identify a systematic sample of five prenatal care providers in each U.S. state and the District of Columbia. Beginning with the lowest zip code in each state, we took every fifth name from the directory, excluding providers who were retired, did not currently practice in the state in which they were listed, or were not involved in a prenatal specialty. After repeating this step twice and sending a total of 461 invitations, 37 providers expressed interest in participating, and we completed telephone interviews with 21 providers (4.6%). We developed a semi-structured interview guide including questions about providers’ use of and attitudes toward cfDNA screening. A single interviewer conducted and audio-recorded all interviews by telephone, and the interviews lasted approximately 30 minutes each. We collaboratively developed a codebook through an iterative process of transcript review and code application, and a primary coder coded all transcripts. Results Prenatal care providers have varying perspectives on the advantages of cfDNA screening and express a range of concerns regarding the implementation of cfDNA screening in practice. While providers agreed on several advantages of cfDNA, including increased accuracy, earlier return of results, and decreased risk of complications, many expressed concern that there is not enough time to adequately counsel and educate patients on their prenatal screening and testing options. Providers also agreed that demand for cfDNA screening has increased and expressed a desire for more information from professional societies, labs, and publications. Providers disagreed about the healthcare implications and future of cfDNA screening. Some providers anticipated that cfDNA screening would decrease healthcare costs when implemented widely and expressed optimism for expanded cfDNA screening panels. Others were concerned that cfDNA screening would increase costs over time and questioned whether the expansion to include microdeletions could be done ethically. Conclusions The perspectives and experiences of the providers in this study allow insight into the clinical benefit, burden on prenatal practice, and potential future of cfDNA screening in clinical practice. Given the likelihood that the scope and uptake of cfDNA screening will continue to increase, it is essential to consider how these changes will affect frontline prenatal care providers and, in turn, patients. Providers’ requests for additional guidance and data as well as their concerns with the lack of time available to explain screening and testing options indicate significant potential issues with patient care. It is important to ensure that the clinical integration of cfDNA screening is managed responsibly and ethically before it expands further, exacerbating pre-existing issues. As prenatal screening evolves, so should informed consent and the resources available to women making decisions. The field must take steps to maximize the advantages of cfDNA screening and responsibly manage its ethical issues. PMID:28180146

  8. "I think we've got too many tests!": Prenatal providers' reflections on ethical and clinical challenges in the practice integration of cell-free DNA screening.

    PubMed

    Gammon, B L; Kraft, S A; Michie, M; Allyse, M

    2016-01-01

    The recent introduction of cell-free DNA-based non-invasive prenatal screening (cfDNA screening) into clinical practice was expected to revolutionize prenatal testing. cfDNA screening for fetal aneuploidy has demonstrated higher test sensitivity and specificity for some conditions than conventional serum screening and can be conducted early in the pregnancy. However, it is not clear whether and how clinical practices are assimilating this new type of testing into their informed consent and counselling processes. Since the introduction of cfDNA screening into practice in 2011, the uptake and scope have increased dramatically. Prenatal care providers are under pressure to stay up to date with rapidly changing cfDNA screening panels, manage increasing patient demands, and keep up with changing test costs, all while attempting to use the technology responsibly and ethically. While clinical literature on cfDNA screening has shown benefits for specific patient populations, it has also identified significant misunderstandings among providers and patients alike about the power of the technology. The unique features of cfDNA screening, in comparison to established prenatal testing technologies, have implications for informed decision-making and genetic counselling that must be addressed to ensure ethical practice. This study explored the experiences of prenatal care providers at the forefront of non-invasive genetic screening in the United States to understand how this testing changes the practice of prenatal medicine. We aimed to learn how the experience of providing and offering this testing differs from established prenatal testing methodologies. These differences may necessitate changes to patient education and consent procedures to maintain ethical practice. We used the online American Congress of Obstetricians and Gynecologists Physician Directory to identify a systematic sample of five prenatal care providers in each U.S. state and the District of Columbia. Beginning with the lowest zip code in each state, we took every fifth name from the directory, excluding providers who were retired, did not currently practice in the state in which they were listed, or were not involved in a prenatal specialty. After repeating this step twice and sending a total of 461 invitations, 37 providers expressed interest in participating, and we completed telephone interviews with 21 providers (4.6%). We developed a semi-structured interview guide including questions about providers' use of and attitudes toward cfDNA screening. A single interviewer conducted and audio-recorded all interviews by telephone, and the interviews lasted approximately 30 minutes each. We collaboratively developed a codebook through an iterative process of transcript review and code application, and a primary coder coded all transcripts. Prenatal care providers have varying perspectives on the advantages of cfDNA screening and express a range of concerns regarding the implementation of cfDNA screening in practice. While providers agreed on several advantages of cfDNA, including increased accuracy, earlier return of results, and decreased risk of complications, many expressed concern that there is not enough time to adequately counsel and educate patients on their prenatal screening and testing options. Providers also agreed that demand for cfDNA screening has increased and expressed a desire for more information from professional societies, labs, and publications. Providers disagreed about the healthcare implications and future of cfDNA screening. Some providers anticipated that cfDNA screening would decrease healthcare costs when implemented widely and expressed optimism for expanded cfDNA screening panels. Others were concerned that cfDNA screening would increase costs over time and questioned whether the expansion to include microdeletions could be done ethically. The perspectives and experiences of the providers in this study allow insight into the clinical benefit, burden on prenatal practice, and potential future of cfDNA screening in clinical practice. Given the likelihood that the scope and uptake of cfDNA screening will continue to increase, it is essential to consider how these changes will affect frontline prenatal care providers and, in turn, patients. Providers' requests for additional guidance and data as well as their concerns with the lack of time available to explain screening and testing options indicate significant potential issues with patient care. It is important to ensure that the clinical integration of cfDNA screening is managed responsibly and ethically before it expands further, exacerbating pre-existing issues. As prenatal screening evolves, so should informed consent and the resources available to women making decisions. The field must take steps to maximize the advantages of cfDNA screening and responsibly manage its ethical issues.

  9. FDA & digital mammography: why has FDA required full field digital mammography systems to be regulated as potentially dangerous devices for more than 10 years?

    PubMed

    Nields, Morgan W

    2010-05-01

    Digital mammography is routinely used in the US to screen asymptomatic women for breast cancer and currently over 50% of US screening centers employ the technology. In spite of FDAs knowledge that digital mammography requires less radiation than film mammography and that its equivalence has been proven in a prospective randomized trial, the agency has failed to allow the technology market access via the 510(k) pre market clearance pathway. As a result of the restrictive Pre Market Approval process, only four suppliers have received FDA approval. The resulting lack of a competitive market has kept costs high, restricted technological innovation, and impeded product improvements as a result of PMA requirements. Meanwhile, at least twelve companies are on the market in the EU and the resulting competitive market has lowered costs and provided increased technological choice. A cultural change with new leadership occurred in the early 90's at FDA. The historical culture at the Center for Devices and Radiological Health of collaboration and education gave way to one characterized by a lack of reliance on outside scientific expertise, tolerance of decision making by unqualified reviewers, and an emphasis on enforcement and punishment. Digital mammography fell victim to this cultural change and as a result major innovations like breast CT and computer aided detection technologies are also withheld from the market. The medical device law, currently under review by the Institute of Medicine, should be amended by the Congress so that new technologies can be appropriately classified in accordance with the risk based assessment classification system detailed in Chapter V of the Federal Food, Drug, and Cosmetic Act. A panel of scientific experts chartered by the NIH or IOM should determine the classification appropriate for new technologies that have no historical regulatory framework. This would be binding on FDA. Unless the law is changed we will likely again experience additional debacles similar to that of digital mammography where important technology has been withheld from millions of women for more than a decade. Copyright 2010 AUR. Published by Elsevier Inc. All rights reserved.

  10. Understanding the digital divide in the clinical setting: the technology knowledge gap experienced by US safety net patients during teleretinal screening.

    PubMed

    George, Sheba; Moran, Erin; Fish, Allison; Ogunyemi, Lola

    2013-01-01

    Differential access to everyday technology and healthcare amongst safety net patients is associated with low technological and health literacies, respectively. These low rates of literacy produce a complex patient "knowledge gap" that influences the effectiveness of telehealth technologies. To understand this "knowledge gap", six focus groups (2 African-American and 4 Latino) were conducted with patients who received teleretinal screenings in U.S. urban safety-net settings. Findings indicate that patients' "knowledge gap" is primarily produced at three points: (1) when patients' preexisting personal barriers to care became exacerbated in the clinical setting; (2) through encounters with technology during screening; and (3) in doctor-patient follow-up. This "knowledge gap" can produce confusion and fear, potentially affecting patients' confidence in quality of care and limiting their disease management ability. In rethinking the digital divide to include the consequences of this knowledge gap faced by patients in the clinical setting, we suggest that patient education focus on both their disease and specific telehealth technologies deployed in care delivery.

  11. Closing the feedback loop: engaging students in large first-year mathematics test revision sessions using pen-enabled screens

    NASA Astrophysics Data System (ADS)

    Donovan, Diane; Loch, Birgit

    2013-01-01

    How can active learning, peer learning and prompt feedback be achieved in large first-year mathematics classes? Further, what technologies may support these aims? In this article, we assert that test revision sessions in first-year mathematics held in a technology-enhanced lecture theatre can be highly interactive with students solving problems, learning from each other and receiving immediate feedback. This is facilitated by pen-enabled screens and synchronization software. We argue that the educational benefits achievable through the technology do outweigh the technological distractions, and that these benefits can be achieved by focused, targeted one-off sessions and not only by a semester-long, regular approach. Repeat mid-semester test revision sessions were offered on a non-compulsory basis using pen-enabled screens for all students. Students worked practice test questions and marked solutions to mathematical problems on the screens. Students' work was then displayed anonymously for their peers to see. Answers were discussed with the whole class. We discuss outcomes from two offerings of these sessions using student feedback and lecturer reflections and show the impact of participation on self-reported student confidence. Pedagogical approaches that the technology allowed for the first time in a large class are highlighted. Students responded uniformly positively.

  12. Finding the Needle in the Haystack-the Use of Microfluidic Droplet Technology to Identify Vitamin-Secreting Lactic Acid Bacteria.

    PubMed

    Chen, Jun; Vestergaard, Mike; Jensen, Thomas Glasdam; Shen, Jing; Dufva, Martin; Solem, Christian; Jensen, Peter Ruhdal

    2017-05-30

    Efficient screening technologies aim to reduce both the time and the cost required for identifying rare mutants possessing a phenotype of interest in a mutagenized population. In this study, we combined a mild mutagenesis strategy with high-throughput screening based on microfluidic droplet technology to identify Lactococcus lactis variants secreting vitamin B 2 (riboflavin). Initially, we used a roseoflavin-resistant mutant of L. lactis strain MG1363, JC017, which secreted low levels of riboflavin. By using fluorescence-activated droplet sorting, several mutants that secreted riboflavin more efficiently than JC017 were readily isolated from the mutagenesis library. The screening was highly efficient, and candidates with as few as 1.6 mutations per million base pairs (Mbp) were isolated. The genetic characterization revealed that riboflavin production was triggered by mutations inhibiting purine biosynthesis, which is surprising since the purine nucleotide GTP is a riboflavin precursor. Purine starvation in the mutants induced overexpression of the riboflavin biosynthesis cluster ribABGH When the purine starvation was relieved by purine supplementation in the growth medium, the outcome was an immediate downregulation of the riboflavin biosynthesis cluster and a reduction in riboflavin production. Finally, by applying the new isolates in milk fermentation, the riboflavin content of milk (0.99 mg/liter) was improved to 2.81 mg/liter, compared with 0.66 mg/liter and 1.51 mg/liter by using the wild-type strain and the original roseoflavin-resistant mutant JC017, respectively. The results obtained demonstrate how powerful classical mutagenesis can be when combined with droplet-based microfluidic screening technology for obtaining microorganisms with useful attributes. IMPORTANCE The food industry prefers to use classical approaches, e.g., random mutagenesis followed by screening, to improve microorganisms used in food production, as the use of recombinant DNA technologies is still not widely accepted. Although modern automated screening platforms are widely accessible, screening remains as a bottleneck in strain development, especially when a mild mutagenesis approach is applied to reduce the chance of accumulating unintended mutations, which may cause unwanted phenotypic changes. Here, we incorporate a droplet-based high-throughput screening method into the strain development process and readily capture L. lactis variants with more efficient vitamin secretion from low-error-rate mutagenesis libraries. This study shows that useful mutants showing strong phenotypes but without extensive mutations can be identified with efficient screening technologies. It is therefore possible to avoid accumulating detrimental mutations while enriching beneficial ones through iterative mutagenesis screening. Due to the low mutation rates, the genetic determinants are also readily identified. Copyright © 2017 Chen et al.

  13. Cost-Effectiveness of Old and New Technologies for Aneuploidy Screening.

    PubMed

    Sinkey, Rachel G; Odibo, Anthony O

    2016-06-01

    Cost-effectiveness analyses allow assessment of whether marginal gains from new technology are worth increased costs. Several studies have examined cost-effectiveness of Down syndrome (DS) screening and found it to be cost-effective. Noninvasive prenatal screening also appears to be cost-effective among high-risk women with respect to DS screening, but not for the general population. Chromosomal microarray (CMA) is a genetic sequencing method superior to but more expensive than karyotype. In light of CMAs greater ability to detect genetic abnormalities, it is cost-effective when used for prenatal diagnosis of an anomalous fetus. This article covers methodology and salient issues of cost-effectiveness. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Potential Influences of Exergaming on Self-Efficacy for Physical Activity and Sport

    ERIC Educational Resources Information Center

    Krause, Jennifer M.; Benavidez, Eddie A.

    2014-01-01

    Screen time, including video gaming, has been perceived to be a major catalyst for the lack of physical activity among youth. However, exergaming has pierced the technology and physical activity scenes with a twist, and happens to be redefining how technology and "screen time" are now being viewed as catalysts for increasing physical…

  15. When "Promotoras" and Technology Meet: A Qualitative Analysis of "Promotoras'" Use of Small Media to Increase Cancer Screening among South Texas Latinos

    ERIC Educational Resources Information Center

    Arvey, Sarah R.; Fernandez, Maria E.; LaRue, Denise M.; Bartholomew, L. Kay

    2012-01-01

    Computer-based multimedia technologies can be used to tailor health messages, but "promotoras" (Spanish-speaking community health workers) rarely use these tools. "Promotoras" delivered health messages about colorectal cancer screening to medically underserved Latinos in South Texas using two small media formats: a…

  16. Can Coolness Predict Technology Adoption? Effects of Perceived Coolness on User Acceptance of Smartphones with Curved Screens.

    PubMed

    Kim, Ki Joon; Shin, Dong-Hee; Park, Eunil

    2015-09-01

    This study proposes an acceptance model for curved-screen smartphones, and explores how the sense of coolness induced by attractiveness, originality, subcultural appeal, and the utility of the curved screen promotes smartphone adoption. The results of structural equation modeling analyses (N = 246) show that these components of coolness (except utility) increase the acceptance of the technology by enhancing the smartphones' affectively driven qualities rather than their utilitarian ones. The proposed coolness model is then compared with the original technology acceptance model to validate that the coolness factors are indeed equally effective determinants of usage intention, as are the extensively studied usability factors such as perceived ease of use and usefulness.

  17. Screening effect in matrix graphene / SiC planar field emmiters

    NASA Astrophysics Data System (ADS)

    Jityaev, I. L.; Svetlichnyi, A. M.; Kolomiytsev, A. S.; Ageev, O. A.

    2017-11-01

    The paper describes simulation of matrix field emission nanostructures on the basis of graphene on a semi-insulating silicon carbide. The planar spike-type field emission cathodes were measured. The electric field distribution in an interelectrode gap of the emission structure was obtained. The models take into account the distance between cathode tops. Screening effect condition was detected in planar field emission structure and a way of eliminating was proposed.

  18. Evaluating the environmental impacts of a nano-enhanced field emission display using life cycle assessment: a screening-level study.

    PubMed

    Upadhyayula, Venkata K K; Meyer, David E; Curran, Mary Ann; Gonzalez, Michael A

    2014-01-21

    Carbon nanotube (CNT) field emission displays (FEDs) are currently in the product development stage and are expected to be commercialized in the near future because they offer image quality and viewing angles comparable to a cathode ray tube (CRT) while using a thinner structure, similar to a liquid crystal display (LCD), and enable more efficient power consumption during use. To address concerns regarding the environmental performance of CNT-FEDs, a screening-level, cradle-to-grave life cycle assessment (LCA) was conducted based on a functional unit of 10,000 viewing hours, the viewing lifespan of a CNT-FED. Contribution analysis suggests the impacts for material acquisition and manufacturing are greater than the combined impacts for use and end-of-life. A scenario analysis of the CNT paste composition identifies the metal components used in the paste are key contributors to the impacts of the upstream stages due to the impacts associated with metal preparation. Further improvement of the manufacturing impacts is possible by considering the use of plant-based oils, such as rapeseed oil, as alternatives to organic solvents for dispersion of CNTs. Given the differences in viewing lifespan, the impacts of the CNT-FED were compared with a LCD and a CRT display to provide more insight on how to improve the CNT-FED to make it a viable product alternative. When compared with CRT technology, CNT-FEDs show better environmental performance, whereas a comparison with LCD technology indicates the environmental impacts are roughly the same. Based on the results, the enhanced viewing capabilities of CNT-FEDs will be a more viable display option if manufacturers can increase the product's expected viewing lifespan.

  19. e-Addictology: An Overview of New Technologies for Assessing and Intervening in Addictive Behaviors.

    PubMed

    Ferreri, Florian; Bourla, Alexis; Mouchabac, Stephane; Karila, Laurent

    2018-01-01

    New technologies can profoundly change the way we understand psychiatric pathologies and addictive disorders. New concepts are emerging with the development of more accurate means of collecting live data, computerized questionnaires, and the use of passive data. Digital phenotyping , a paradigmatic example, refers to the use of computerized measurement tools to capture the characteristics of different psychiatric disorders. Similarly, machine learning-a form of artificial intelligence-can improve the classification of patients based on patterns that clinicians have not always considered in the past. Remote or automated interventions (web-based or smartphone-based apps), as well as virtual reality and neurofeedback, are already available or under development. These recent changes have the potential to disrupt practices, as well as practitioners' beliefs, ethics and representations, and may even call into question their professional culture. However, the impact of new technologies on health professionals' practice in addictive disorder care has yet to be determined. In the present paper, we therefore present an overview of new technology in the field of addiction medicine. Using the keywords [e-health], [m-health], [computer], [mobile], [smartphone], [wearable], [digital], [machine learning], [ecological momentary assessment], [biofeedback] and [virtual reality], we searched the PubMed database for the most representative articles in the field of assessment and interventions in substance use disorders. We screened 595 abstracts and analyzed 92 articles, dividing them into seven categories: e-health program and web-based interventions, machine learning, computerized adaptive testing, wearable devices and digital phenotyping, ecological momentary assessment, biofeedback, and virtual reality. This overview shows that new technologies can improve assessment and interventions in the field of addictive disorders. The precise role of connected devices, artificial intelligence and remote monitoring remains to be defined. If they are to be used effectively, these tools must be explained and adapted to the different profiles of physicians and patients. The involvement of patients, caregivers and other health professionals is essential to their design and assessment.

  20. A Threat to Childhood Innocence or the Future of Learning? Parents' Perspectives on the Use of Touch-Screen Technology by 0-3 Year-Olds in the UK

    ERIC Educational Resources Information Center

    O'Connor, Jane; Fotakopoulou, Olga

    2016-01-01

    The rise in personal ownership of touch-screen technology such as iPads and smartphones in the UK in recent years has led to the increasing use of such technology by babies and very young children. This article explores this practice via an online parental survey with 226 UK parents of children aged 0-3 years within the context of the current…

  1. High Throughput Transcriptomics: From screening to pathways

    EPA Science Inventory

    The EPA ToxCast effort has screened thousands of chemicals across hundreds of high-throughput in vitro screening assays. The project is now leveraging high-throughput transcriptomic (HTTr) technologies to substantially expand its coverage of biological pathways. The first HTTr sc...

  2. In vivo robotics: the automation of neuroscience and other intact-system biological fields.

    PubMed

    Kodandaramaiah, Suhasa B; Boyden, Edward S; Forest, Craig R

    2013-12-01

    Robotic and automation technologies have played a huge role in in vitro biological science, having proved critical for scientific endeavors such as genome sequencing and high-throughput screening. Robotic and automation strategies are beginning to play a greater role in in vivo and in situ sciences, especially when it comes to the difficult in vivo experiments required for understanding the neural mechanisms of behavior and disease. In this perspective, we discuss the prospects for robotics and automation to influence neuroscientific and intact-system biology fields. We discuss how robotic innovations might be created to open up new frontiers in basic and applied neuroscience and present a concrete example with our recent automation of in vivo whole-cell patch clamp electrophysiology of neurons in the living mouse brain. © 2013 New York Academy of Sciences.

  3. Molecular targets of alcohol action: translational research for pharmacotherapy development and screening

    PubMed Central

    Gorini, Giorgio; Bell, Richard L.; Mayfield, R. Dayne

    2016-01-01

    Summary Alcohol abuse and dependence are multifaceted disorders with neurobiological, psychological, and environmental components. Research on other complex neuropsychiatric diseases suggests that genetically influenced intermediate characteristics affect the risk for heavy alcohol consumption and its consequences. Diverse therapeutic interventions can be developed through identification of reliable biomarkers for this disorder and new pharmacological targets for its treatment. Advances in the fields of genomics and proteomics offer a number of possible targets for the development of new therapeutic approaches. This brain-focused review highlights studies identifying neurobiological systems associated with these targets and possible pharmacotherapies, summarizing evidence from clinically relevant animal and human studies, as well as sketching improvements and challenges facing the fields of proteomics and genomics. Concluding thoughts on using results from these profiling technologies for medication development are also presented. PMID:21199775

  4. A Systematic Evaluation of Field-Based Screening Methods for the Assessment of Anterior Cruciate Ligament (ACL) Injury Risk.

    PubMed

    Fox, Aaron S; Bonacci, Jason; McLean, Scott G; Spittle, Michael; Saunders, Natalie

    2016-05-01

    Laboratory-based measures provide an accurate method to identify risk factors for anterior cruciate ligament (ACL) injury; however, these methods are generally prohibitive to the wider community. Screening methods that can be completed in a field or clinical setting may be more applicable for wider community use. Examination of field-based screening methods for ACL injury risk can aid in identifying the most applicable method(s) for use in these settings. The objective of this systematic review was to evaluate and compare field-based screening methods for ACL injury risk to determine their efficacy of use in wider community settings. An electronic database search was conducted on the SPORTDiscus™, MEDLINE, AMED and CINAHL databases (January 1990-July 2015) using a combination of relevant keywords. A secondary search of the same databases, using relevant keywords from identified screening methods, was also undertaken. Studies identified as potentially relevant were independently examined by two reviewers for inclusion. Where consensus could not be reached, a third reviewer was consulted. Original research articles that examined screening methods for ACL injury risk that could be undertaken outside of a laboratory setting were included for review. Two reviewers independently assessed the quality of included studies. Included studies were categorized according to the screening method they examined. A description of each screening method, and data pertaining to the ability to prospectively identify ACL injuries, validity and reliability, recommendations for identifying 'at-risk' athletes, equipment and training required to complete screening, time taken to screen athletes, and applicability of the screening method across sports and athletes were extracted from relevant studies. Of 1077 citations from the initial search, a total of 25 articles were identified as potentially relevant, with 12 meeting all inclusion/exclusion criteria. From the secondary search, eight further studies met all criteria, resulting in 20 studies being included for review. Five ACL-screening methods-the Landing Error Scoring System (LESS), Clinic-Based Algorithm, Observational Screening of Dynamic Knee Valgus (OSDKV), 2D-Cam Method, and Tuck Jump Assessment-were identified. There was limited evidence supporting the use of field-based screening methods in predicting ACL injuries across a range of populations. Differences relating to the equipment and time required to complete screening methods were identified. Only screening methods for ACL injury risk were included for review. Field-based screening methods developed for lower-limb injury risk in general may also incorporate, and be useful in, screening for ACL injury risk. Limited studies were available relating to the OSDKV and 2D-Cam Method. The LESS showed predictive validity in identifying ACL injuries, however only in a youth athlete population. The LESS also appears practical for community-wide use due to the minimal equipment and set-up/analysis time required. The Clinic-Based Algorithm may have predictive value for ACL injury risk as it identifies athletes who exhibit high frontal plane knee loads during a landing task, but requires extensive additional equipment and time, which may limit its application to wider community settings.

  5. SU-F-T-232: Monthly Quality Assurance in External Beam Radiation Therapy Using a Single System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ding, K; Ji, T; Department of Radiation Oncology, The First Hospital, China Medical University, Shenyang, Liaoning

    Purpose: Monthly quality assurance (QA) is time consuming for external beam radiation therapy, taking as long as 6–8 hours for each machine. It is due to the use and setup of multiple devices for different QA procedures. We have developed a single system with rotational capability for the measurement of both optical light and radiation which significantly reduces the time spent on Monthly QA. Methods: A single system using mirrors, a phosphor screen and a CCD camera is housed on a cylindrical motor so that it can rotate 360 degrees. For monthly QA, the system is placed on the patientmore » couch of the medical accelerator with the plane of the phosphor screen at isocenter for all measurements. For optical QA such as optical distance indicator, room laser and light field, the optical image is collected directly with the camera. For radiation QA such as beam profile, MLC speed, picket-fence test, collimator rotation, table rotation and gantry rotation, a brass build-up plate is attached to the top of the phosphor screen. Two brass plates with islands of different thickness were designed for photon energy and electron energy constancy checks. Flex map, distortion map and uniformity map were developed to calibrate the motor bearing, camera/lens distortion, and the phosphor screen’s measured response across the field. Results: Following the TG142 guidelines for monthly QA with our system, the overall run time is reduced from 6–8 hours to 1.5 hours. Our system’s rotating design allows for quick testing of the gantry radiation isocenter test that is also independent of the sag of the gantry and the EPID. Conclusion: Our system significantly shortens the time needed for monthly QA by unifying the tests with a single system. Future work will be focused on extending the technology to Brachytherapy, IMRT and proton therapy QAs. This work is funded in part by a sponsor research grant from JPLC who owns the Raven technology. John Wong is a co-founder of JPLC.« less

  6. Evaluation of viewing experiences induced by curved 3D display

    NASA Astrophysics Data System (ADS)

    Mun, Sungchul; Park, Min-Chul; Yano, Sumio

    2015-05-01

    As advanced display technology has been developed, much attention has been given to flexible panels. On top of that, with the momentum of the 3D era, stereoscopic 3D technique has been combined with the curved displays. However, despite the increased needs for 3D function in the curved displays, comparisons between curved and flat panel displays with 3D views have rarely been tested. Most of the previous studies have investigated their basic ergonomic aspects such as viewing posture and distance with only 2D views. It has generally been known that curved displays are more effective in enhancing involvement in specific content stories because field of views and distance from the eyes of viewers to both edges of the screen are more natural in curved displays than in flat panel ones. For flat panel displays, ocular torsions may occur when viewers try to move their eyes from the center to the edges of the screen to continuously capture rapidly moving 3D objects. This is due in part to differences in viewing distances from the center of the screen to eyes of viewers and from the edges of the screen to the eyes. Thus, this study compared S3D viewing experiences induced by a curved display with those of a flat panel display by evaluating significant subjective and objective measures.

  7. Rapid Screening of Cancer Margins in Tissue with Multimodal Confocal Microscopy

    PubMed Central

    Gareau, Daniel S.; Jeon, Hana; Nehal, Kishwer S.; Rajadhyaksha, Milind

    2012-01-01

    Background Complete and accurate excision of cancer is guided by the examination of histopathology. However, preparation of histopathology is labor intensive and slow, leading to insufficient sampling of tissue and incomplete and/or inaccurate excision of margins. We demonstrate the potential utility of multimodal confocal mosaicing microscopy for rapid screening of cancer margins, directly in fresh surgical excisions, without the need for conventional embedding, sectioning or processing. Materials/Methods A multimodal confocal mosaicing microscope was developed to image basal cell carcinoma margins in surgical skin excisions, with resolution that shows nuclear detail. Multimodal contrast is with fluorescence for imaging nuclei and reflectance for cellular cytoplasm and dermal collagen. Thirtyfive excisions of basal cell carcinomas from Mohs surgery were imaged, and the mosaics analyzed by comparison to the corresponding frozen pathology. Results Confocal mosaics are produced in about 9 minutes, displaying tissue in fields-of-view of 12 mm with 2X magnification. A digital staining algorithm transforms black and white contrast to purple and pink, which simulates the appearance of standard histopathology. Mosaicing enables rapid digital screening, which mimics the examination of histopathology. Conclusions Multimodal confocal mosaicing microscopy offers a technology platform to potentially enable real-time pathology at the bedside. The imaging may serve as an adjunct to conventional histopathology, to expedite screening of margins and guide surgery toward more complete and accurate excision of cancer. PMID:22721570

  8. A novel x-ray imaging system and its imaging performance

    NASA Astrophysics Data System (ADS)

    Yu, Chunyu; Chang, Benkang; Wang, Shiyun; Zhang, Junju; Yao, Xiao

    2006-09-01

    Since x-ray was discovered and applied to the imaging technology, the x-ray imaging techniques have experienced several improvements, from film-screen, x-ray image intensifier, CR to DR. To store and transmit the image information conveniently, the digital imaging is necessary for the imaging techniques in medicine and biology. Usually as the intensifying screen technique as for concerned, to get the digital image signals, the CCD was lens coupled directly to the screen, but which suffers from a loss of x-ray signal and resulted in the poor x-ray image perfonnance. Therefore, to improve the image performance, we joined the brightness intensifier, which, was named the Low Light Level (LLL) image intensifier in military affairs, between the intensifying screen and the CCD and designed the novel x-ray imaging system. This design method improved the image performance of the whole system thus decreased the x-ray dose. Comparison between two systems with and without the brightness intensifier was given in detail in this paper. Moreover, the main noise source of the image produced by the novel system was analyzed, and in this paper, the original images produced by the novel x-ray imaging system and the processed images were given respectively. It was clear that the image performance was satisfied and the x-ray imaging system can be used in security checking and many other nondestructive checking fields.

  9. New solid-state chemistry technologies to bring better drugs to market: knowledge-based decision making.

    PubMed

    Park, Aeri; Chyall, Leonard J; Dunlap, Jeanette; Schertz, Christine; Jonaitis, David; Stahly, Barbara C; Bates, Simon; Shipplett, Rex; Childs, Scott

    2007-01-01

    Modern drug development demands constant deployment of more effective technologies to mitigate the high cost of bringing new drugs to market. In addition to cost savings, new technologies can improve all aspects of pharmaceutical development. New technologies developed at SSCI, Inc. include solid form development of an active pharmaceutical ingredients. (APIs) are PatternMatch software and capillary-based crystallisation techniques that not only allow for fast and effective solid form screening, but also extract maximum property information from the routine screening data that is generally available. These new technologies offer knowledge-based decision making during solid form development of APIs and result in more developable API solid forms.

  10. Dangerous and Expensive Screening and Treatment for Rare Childhood Diseases: The Case of Krabbe Disease

    ERIC Educational Resources Information Center

    Lantos, John D.

    2011-01-01

    Public policy surrounding newborn screening is in flux. New technology allows more screening for more diseases at lower cost. Traditional criteria for target diseases have been criticized by leading health policymakers. The example of newborn screening for Krabbe disease highlights many of the dilemmas associated with population-based screening…

  11. Microfluidics and Cancer: Are we there yet?

    PubMed Central

    Zhang, Jennifer Zhuo; Nagrath, Sunitha

    2013-01-01

    More than two decades ago, microfluidics began to show its impact in biological research. Since then, the field of microfluidics has evolving rapidly. Cancer is one of the leading causes of death worldwide. Microfluidics holds great promise in cancer diagnosis and also serves as an emerging tool for understanding cancer biology. Microfluidics can be valuable for cancer investigation due to its high sensitivity, high throughput, less material-consumption, low cost, and enhanced spatio-temporal control. The physical laws on microscale offer an advantage enabling the control of physics, biology, chemistry and physiology at cellular level. Furthermore, microfluidic based platforms are portable and can be easily designed for point-of-care diagnostics. Developing and applying the state of the art microfluidic technologies to address the unmet challenges in cancer can expand the horizons of not only fundamental biology but also the management of disease and patient care. Despite the various microfluidic technologies available in the field, few have been tested clinically, which can be attributed to the various challenges existing in bridging the gap between the emerging technology and real world applications. We present a review of role of microlfuidcs in cancer research, including the history, recent advances and future directions to explore where the field stand currently in addressing complex clinical challenges and future of it. This review identifies four critical areas in cancer research, in which microfluidics can change the current paradigm. These include cancer cell isolation, molecular diagnostics, tumor biology and high-throughput screening for therapeutics. In addition, some of our lab’s current research is presented in the corresponding sections. PMID:23358873

  12. F2 screen, inheritance and cross-resistance of field-derived Vip3A resistance in Spodoptera frugiperda (Lepidoptera: Noctuidae) collected from Louisiana, USA.

    PubMed

    Yang, Fei; Morsello, Shannon; Head, Graham P; Sansone, Chris; Huang, Fangneng; Gilreath, Ryan T; Kerns, David L

    2017-11-28

    Fall armyworm, Spodoptera frugiperda, is a target pest of the Vip3A protein used in pyramided Bt corn and cotton in the USA. In this study, we provide the first documentation of a resistance allele conferring Vip3A resistance in a field-derived population of S. frugiperda from the USA, and characterize its inheritance and cross-resistance. An F 2 screen with 104 two-parent families generated from a field collection of S. frugiperda in Louisiana, USA, resulted in one family carrying a Vip3A resistance allele. The Vip3A-resistant strain (RR) derived from the two-parent family showed a high level of resistance to Vip3A in both diet and whole-plant bioassays, with a resistance ratio of >632.0-fold relative to a susceptible population (SS) based on diet-overlay bioassays. The inheritance of Vip3A resistance was monogenic, autosomal and recessive. Furthermore, the Vip3A resistance conferred no cross-resistance to Cry1F, Cry2Ab2 or Cry2Ae purified proteins, with resistance ratios of 3.5, 5.0 and 1.1, respectively. These findings provide valuable information for characterizing Vip3A resistance, resistance monitoring, and developing effective resistance management strategies for the sustainable use of the Vip3A technology. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  13. 20180311 - High Throughput Transcriptomics: From screening to pathways (SOT 2018)

    EPA Science Inventory

    The EPA ToxCast effort has screened thousands of chemicals across hundreds of high-throughput in vitro screening assays. The project is now leveraging high-throughput transcriptomic (HTTr) technologies to substantially expand its coverage of biological pathways. The first HTTr sc...

  14. Ultrahigh speed en face OCT capsule for endoscopic imaging

    PubMed Central

    Liang, Kaicheng; Traverso, Giovanni; Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Wang, Zhao; Potsaid, Benjamin; Giacomelli, Michael; Jayaraman, Vijaysekhar; Barman, Ross; Cable, Alex; Mashimo, Hiroshi; Langer, Robert; Fujimoto, James G.

    2015-01-01

    Depth resolved and en face OCT visualization in vivo may have important clinical applications in endoscopy. We demonstrate a high speed, two-dimensional (2D) distal scanning capsule with a micromotor for fast rotary scanning and a pneumatic actuator for precision longitudinal scanning. Longitudinal position measurement and image registration were performed by optical tracking of the pneumatic scanner. The 2D scanning device enables high resolution imaging over a small field of view and is suitable for OCT as well as other scanning microscopies. Large field of view imaging for screening or surveillance applications can also be achieved by proximally pulling back or advancing the capsule while scanning the distal high-speed micromotor. Circumferential en face OCT was demonstrated in living swine at 250 Hz frame rate and 1 MHz A-scan rate using a MEMS tunable VCSEL light source at 1300 nm. Cross-sectional and en face OCT views of the upper and lower gastrointestinal tract were generated with precision distal pneumatic longitudinal actuation as well as proximal manual longitudinal actuation. These devices could enable clinical studies either as an adjunct to endoscopy, attached to an endoscope, or as a swallowed tethered capsule for non-endoscopic imaging without sedation. The combination of ultrahigh speed imaging and distal scanning capsule technology could enable both screening and surveillance applications. PMID:25909001

  15. Ultrahigh speed en face OCT capsule for endoscopic imaging.

    PubMed

    Liang, Kaicheng; Traverso, Giovanni; Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Wang, Zhao; Potsaid, Benjamin; Giacomelli, Michael; Jayaraman, Vijaysekhar; Barman, Ross; Cable, Alex; Mashimo, Hiroshi; Langer, Robert; Fujimoto, James G

    2015-04-01

    Depth resolved and en face OCT visualization in vivo may have important clinical applications in endoscopy. We demonstrate a high speed, two-dimensional (2D) distal scanning capsule with a micromotor for fast rotary scanning and a pneumatic actuator for precision longitudinal scanning. Longitudinal position measurement and image registration were performed by optical tracking of the pneumatic scanner. The 2D scanning device enables high resolution imaging over a small field of view and is suitable for OCT as well as other scanning microscopies. Large field of view imaging for screening or surveillance applications can also be achieved by proximally pulling back or advancing the capsule while scanning the distal high-speed micromotor. Circumferential en face OCT was demonstrated in living swine at 250 Hz frame rate and 1 MHz A-scan rate using a MEMS tunable VCSEL light source at 1300 nm. Cross-sectional and en face OCT views of the upper and lower gastrointestinal tract were generated with precision distal pneumatic longitudinal actuation as well as proximal manual longitudinal actuation. These devices could enable clinical studies either as an adjunct to endoscopy, attached to an endoscope, or as a swallowed tethered capsule for non-endoscopic imaging without sedation. The combination of ultrahigh speed imaging and distal scanning capsule technology could enable both screening and surveillance applications.

  16. [Identification of perforating vessels by augmented reality: Application for the deep inferior epigastric perforator flap].

    PubMed

    Bosc, R; Fitoussi, A; Pigneur, F; Tacher, V; Hersant, B; Meningaud, J-P

    2017-08-01

    The augmented reality on smart glasses allows the surgeon to visualize three-dimensional virtual objects during surgery, superimposed in real time to the anatomy of the patient. This makes it possible to preserve the vision of the surgical field and to dispose of added computerized information without the need to use a physical surgical guide or a deported screen. The three-dimensional objects that we used and visualized in augmented reality came from the reconstructions made from the CT-scans of the patients. These objects have been transferred through a dedicated application on stereoscopic smart glasses. The positioning and the stabilization of the virtual layers on the anatomy of the patients were obtained thanks to the recognition, by the glasses, of a tracker placed on the skin. We used this technology, in addition to the usual locating methods for preoperative planning and the selection of perforating vessels for 12 patients operated on a breast reconstruction, by perforating flap of deep lower epigastric artery. The "hands-free" smart glasses with two stereoscopic screens make it possible to provide the reconstructive surgeon with binocular visualization in the operative field of the vessels identified with the CT-scan. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  17. From a genetic innovation to mass health programmes: the diffusion of Down's Syndrome prenatal screening and diagnostic techniques in France.

    PubMed

    Vassy, Carine

    2006-10-01

    Down's Syndrome prenatal diagnostic and screening techniques have spread widely in France over the last 30 years and are now part of the routine clinical practice of prenatal care. These techniques, which originated in the field of genetics, ultrasonography and biochemistry, were the first to provide the possibility of choosing the features of the foetus, or at least to reject some of its characteristics. They lead to new norms of healthy foetuses and a progressive acceptance of medical abortions. The aim of this paper is to understand how the use of these tests has been generalised in France despite scientific controversies about their risks and ethical questioning about a potential renewal of eugenics. It analyses the representations of public needs that have been articulated by key players in the scientific and medical fields. This research explores political and administrative decision making processes to understand how progressively widening public access to prenatal testing has been organised and funded. The results highlight the scientific and political role of biomedical researchers, the forms of involvement of health authorities and politicians, and the passive participation of the vast majority of the users. The paper also examines the characteristics of the French health system that facilitated the generalised use of the technology.

  18. Recent trends in digital halftoning

    NASA Astrophysics Data System (ADS)

    Delabastita, Paul A.

    1997-02-01

    Screening is perhaps the oldest form of image processing. The word refers to the mechanical cross line screens that were used at the beginning of this century for the purpose of photomechanical reproduction. Later on, these mechanical screens were replaced by photographic contact screens that enabled significantly improved process control. In the early eighties, the optical screening on graphic arts scanners was replaced by a combination of laser optics and electronic screening. The algorithms, however, were still digital implementations of the original optical methods. The printing needs in the fast growing computer and software industry gave birth to a number of alternative printing technologies such as electrophotographic and inkjet printing. Originally these deices were only designed for printing text, but soon people started experimenting and using them for printing images. The relatively low spatial resolutions of these new devices however made complete review of 'the screening issue' necessary to achieve an acceptable image quality. In this paper a number of recent developments in screening technology are summarized. Special attention is given to the interaction that exists between a halftone screen and the printing devices on which they are rendered including the color mixing behavior. Improved screening techniques are presented that take advantage of modeling the physical behavior of the rendering device.

  19. Developing a Computer Touch-Screen Interactive Colorectal Screening Decision Aid for a Low-Literacy African American Population: Lessons Learned

    PubMed Central

    Bass, Sarah Bauerle; Gordon, Thomas F.; Ruzek, Sheryl Burt; Wolak, Caitlin; Ruggieri, Dominique; Mora, Gabriella; Rovito, Michael J.; Britto, Johnson; Parameswaran, Lalitha; Abedin, Zainab; Ward, Stephanie; Paranjape, Anuradha; Lin, Karen; Meyer, Brian; Pitts, Khaliah

    2017-01-01

    African Americans have higher colorectal cancer (CRC) mortality than White Americans and yet have lower rates of CRC screening. Increased screening aids in early detection and higher survival rates. Coupled with low literacy rates, the burden of CRC morbidity and mortality is exacerbated in this population, making it important to develop culturally and literacy appropriate aids to help low-literacy African Americans make informed decisions about CRC screening. This article outlines the development of a low-literacy computer touch-screen colonoscopy decision aid using an innovative marketing method called perceptual mapping and message vector modeling. This method was used to mathematically model key messages for the decision aid, which were then used to modify an existing CRC screening tutorial with different messages. The final tutorial was delivered through computer touch-screen technology to increase access and ease of use for participants. Testing showed users were not only more comfortable with the touch-screen technology but were also significantly more willing to have a colonoscopy compared with a “usual care group.” Results confirm the importance of including participants in planning and that the use of these innovative mapping and message design methods can lead to significant CRC screening attitude change. PMID:23132838

  20. Identification and Correction of Additive and Multiplicative Spatial Biases in Experimental High-Throughput Screening.

    PubMed

    Mazoure, Bogdan; Caraus, Iurie; Nadon, Robert; Makarenkov, Vladimir

    2018-06-01

    Data generated by high-throughput screening (HTS) technologies are prone to spatial bias. Traditionally, bias correction methods used in HTS assume either a simple additive or, more recently, a simple multiplicative spatial bias model. These models do not, however, always provide an accurate correction of measurements in wells located at the intersection of rows and columns affected by spatial bias. The measurements in these wells depend on the nature of interaction between the involved biases. Here, we propose two novel additive and two novel multiplicative spatial bias models accounting for different types of bias interactions. We describe a statistical procedure that allows for detecting and removing different types of additive and multiplicative spatial biases from multiwell plates. We show how this procedure can be applied by analyzing data generated by the four HTS technologies (homogeneous, microorganism, cell-based, and gene expression HTS), the three high-content screening (HCS) technologies (area, intensity, and cell-count HCS), and the only small-molecule microarray technology available in the ChemBank small-molecule screening database. The proposed methods are included in the AssayCorrector program, implemented in R, and available on CRAN.

  1. High resolution NMR measurements using a 400MHz NMR with an (RE)Ba2Cu3O7-x high-temperature superconducting inner coil: Towards a compact super-high-field NMR.

    PubMed

    Piao, R; Iguchi, S; Hamada, M; Matsumoto, S; Suematsu, H; Saito, A T; Li, J; Nakagome, H; Takao, T; Takahashi, M; Maeda, H; Yanagisawa, Y

    2016-02-01

    Use of high-temperature superconducting (HTS) inner coils in combination with conventional low-temperature superconducting (LTS) outer coils for an NMR magnet, i.e. a LTS/HTS NMR magnet, is a suitable option to realize a high-resolution NMR spectrometer with operating frequency >1GHz. From the standpoint of creating a compact magnet, (RE: Rare earth) Ba2Cu3O7-x (REBCO) HTS inner coils which can tolerate a strong hoop stress caused by a Lorentz force are preferred. However, in our previous work on a first-generation 400MHz LTS/REBCO NMR magnet, the NMR resolution and sensitivity were about ten times worse than that of a conventional LTS NMR magnet. The result was caused by a large field inhomogeneity in the REBCO coil itself and the shielding effect of a screening current induced in that coil. In the present paper, we describe the operation of a modified 400MHz LTS/REBCO NMR magnet with an advanced field compensation technology using a combination of novel ferromagnetic shimming and an appropriate procedure for NMR spectrum line shape optimization. We succeeded in obtaining a good NMR line shape and 2D NOESY spectrum for a lysozyme aqueous sample. We believe that this technology is indispensable for the realization of a compact super-high-field high-resolution NMR. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Novel 1H low field nuclear magnetic resonance applications for the field of biodiesel

    PubMed Central

    2013-01-01

    Background Biodiesel production has increased dramatically over the last decade, raising the need for new rapid and non-destructive analytical tools and technologies. 1H Low Field Nuclear Magnetic Resonance (LF-NMR) applications, which offer great potential to the field of biodiesel, have been developed by the Phyto Lipid Biotechnology Lab research team in the last few years. Results Supervised and un-supervised chemometric tools are suggested for screening new alternative biodiesel feedstocks according to oil content and viscosity. The tools allowed assignment into viscosity groups of biodiesel-petrodiesel samples whose viscosity is unknown, and uncovered biodiesel samples that have residues of unreacted acylglycerol and/or methanol, and poorly separated and cleaned glycerol and water. In the case of composite materials, relaxation time distribution, and cross-correlation methods were successfully applied to differentiate components. Continuous distributed methods were also applied to calculate the yield of the transesterification reaction, and thus monitor the progress of the common and in-situ transesterification reactions, offering a tool for optimization of reaction parameters. Conclusions Comprehensive applied tools are detailed for the characterization of new alternative biodiesel resources in their whole conformation, monitoring of the biodiesel transesterification reaction, and quality evaluation of the final product, using a non-invasive and non-destructive technology that is new to the biodiesel research area. A new integrated computational-experimental approach for analysis of 1H LF-NMR relaxometry data is also presented, suggesting improved solution stability and peak resolution. PMID:23590829

  3. Illustrating economic evaluation of diagnostic technologies: comparing Helicobacter pylori screening strategies in prevention of gastric cancer in Canada.

    PubMed

    Xie, Feng; O'Reilly, Daria; Ferrusi, Ilia L; Blackhouse, Gord; Bowen, James M; Tarride, Jean-Eric; Goeree, Ron

    2009-05-01

    The aim of this paper is to present an economic evaluation of diagnostic technologies using Helicobacter pylori screening strategies for the prevention of gastric cancer as an illustration. A Markov model was constructed to compare the lifetime cost and effectiveness of 4 potential strategies: no screening, the serology test by enzyme-linked immunosorbent assay (ELISA), the stool antigen test (SAT), and the (13)C-urea breath test (UBT) for the detection of H. pylori among a hypothetical cohort of 10,000 Canadian men aged 35 years. Special parameter consideration included the sensitivity and specificity of each screening strategy, which determined the model structure and treatment regimen. The primary outcome measured was the incremental cost-effectiveness ratio between the screening strategies and the no-screening strategy. Base-case analysis and probabilistic sensitivity analysis were performed using the point estimates of the parameters and Monte Carlo simulations, respectively. Compared with the no-screening strategy in the base-case analysis, the incremental cost-effectiveness ratio was $33,000 per quality-adjusted life-year (QALY) for the ELISA, $29,800 per QALY for the SAT, and $50,400 per QALY for the UBT. The probabilistic sensitivity analysis revealed that the no-screening strategy was more cost effective if the willingness to pay (WTP) was <$20,000 per QALY, while the SAT had the highest probability of being cost effective if the WTP was >$30,000 per QALY. Both the ELISA and the UBT were not cost-effective strategies over a wide range of WTP values. Although the UBT had the highest sensitivity and specificity, either no screening or the SAT could be the most cost-effective strategy depending on the WTP threshold values from an economic perspective. This highlights the importance of economic evaluations of diagnostic technologies.

  4. Out with the old, in with the new: Assessing change in screen time when measurement changes over time.

    PubMed

    Gunnell, Katie E; Brunet, Jennifer; Bélanger, Mathieu

    2018-03-01

    We examined if screen time can be assessed over time when the measurement protocol has changed to reflect advances in technology. Beginning in 2011, 929 youth (9-12 years at time one) living in in New Brunswick (Canada) self-reported the amount of time spent watching television (cycles 1-13), using computers (cycles 1-13), and playing video games (cycles 3-13). Using longitudinal invariance to test a shifting indicators model of screen time, we found that the relationships between the latent variable reflecting overall screen time and the indicators used to assess screen time were invariant across cycles (weak invariance). We also found that 31 out of 37 indicator intercepts were invariant, meaning that most indicators were answered similarly (i.e., on the same metric) across cycles (partial strong invariance), and that 28 out of 37 indicator residuals were invariant indicating that similar sources of error were present over time (partial strict invariance). Overall, across all survey cycles, 76% of indicators were fully invariant. Whereas issues were noted when new examples of screen-based technology (e.g., iPads) were added, having established partial invariance, we suggest it is still possible to assess change in screen time despite having changing indicators over time. Although it is not possible to draw definitive conclusions concerning other self-report measures of screen time, our findings may assist other researchers considering modifying self-report measures in longitudinal studies to reflect technological advancements and increase the precision of their results.

  5. Monocular display unit for 3D display with correct depth perception

    NASA Astrophysics Data System (ADS)

    Sakamoto, Kunio; Hosomi, Takashi

    2009-11-01

    A study of virtual-reality system has been popular and its technology has been applied to medical engineering, educational engineering, a CAD/CAM system and so on. The 3D imaging display system has two types in the presentation method; one is a 3-D display system using a special glasses and the other is the monitor system requiring no special glasses. A liquid crystal display (LCD) recently comes into common use. It is possible for this display unit to provide the same size of displaying area as the image screen on the panel. A display system requiring no special glasses is useful for a 3D TV monitor, but this system has demerit such that the size of a monitor restricts the visual field for displaying images. Thus the conventional display can show only one screen, but it is impossible to enlarge the size of a screen, for example twice. To enlarge the display area, the authors have developed an enlarging method of display area using a mirror. Our extension method enables the observers to show the virtual image plane and to enlarge a screen area twice. In the developed display unit, we made use of an image separating technique using polarized glasses, a parallax barrier or a lenticular lens screen for 3D imaging. The mirror can generate the virtual image plane and it enlarges a screen area twice. Meanwhile the 3D display system using special glasses can also display virtual images over a wide area. In this paper, we present a monocular 3D vision system with accommodation mechanism, which is useful function for perceiving depth.

  6. A CRISPR toolbox to study virus–host interactions

    PubMed Central

    Puschnik, Andreas S.; Majzoub, Karim; Ooi, Yaw Shin; Carette, Jan E.

    2018-01-01

    Viruses depend on their hosts to complete their replication cycles; they exploit cellular receptors for entry and hijack cellular functions to replicate their genome, assemble progeny virions and spread. Recently, genome-scale CRISPR–Cas screens have been used to identify host factors that are required for virus replication, including the replication of clinically relevant viruses such as Zika virus, West Nile virus, dengue virus and hepatitis C virus. In this Review, we discuss the technical aspects of genome-scale knockout screens using CRISPR–Cas technology, and we compare these screens with alternative genetic screening technologies. The relative ease of use and reproducibility of CRISPR–Cas make it a powerful tool for probing virus–host interactions and for identifying new antiviral targets. PMID:28420884

  7. Study of an overload truck screening system for a sustainable highway bridge network.

    DOT National Transportation Integrated Search

    2009-01-01

    he objective of this project was to study the use and implementation of an overload truck screening system for bridge structures. This screening system combines two advanced technologies, namely a weigh-in-motion (WIM) system and a bridge strain sens...

  8. On-chip, multisite extracellular and intracellular recordings from primary cultured skeletal myotubes

    PubMed Central

    Rabieh, Noha; Ojovan, Silviya M.; Shmoel, Nava; Erez, Hadas; Maydan, Eilon; Spira, Micha E.

    2016-01-01

    In contrast to the extensive use of microelectrode array (MEA) technology in electrophysiological studies of cultured neurons and cardiac muscles, the vast field of skeletal muscle research has yet to adopt the technology. Here we demonstrate an empowering MEA technology for high quality, multisite, long-term electrophysiological recordings from cultured skeletal myotubes. Individual rat skeletal myotubes cultured on micrometer sized gold mushroom-shaped microelectrode (gMμE) based MEA tightly engulf the gMμEs, forming a high seal resistance between the myotubes and the gMμEs. As a consequence, spontaneous action potentials generated by the contracting myotubes are recorded as extracellular field potentials with amplitudes of up to 10 mV for over 14 days. Application of a 10 ms, 0.5–0.9 V voltage pulse through the gMμEs electroporated the myotube membrane, and transiently converted the extracellular to intracellular recording mode for 10–30 min. In a fraction of the cultures stable attenuated intracellular recordings were spontaneously produced. In these cases or after electroporation, subthreshold spontaneous potentials were also recorded. The introduction of the gMμE-MEA as a simple-to-use, high-quality electrophysiological tool together with the progress made in the use of cultured human myotubes opens up new venues for basic and clinical skeletal muscle research, preclinical drug screening, and personalized medicine. PMID:27812002

  9. Early screening of an infant's visual system

    NASA Astrophysics Data System (ADS)

    Costa, Manuel F. M.; Jorge, Jorge M.

    1999-06-01

    It is of utmost importance to the development of the child's visual system that she perceives clear focused retinal images. Furthermore if the refractive problems are not corrected in due time amblyopia may occur--myopia and hyperopia can only cause important problems in the future when they are significantly large, however for the astigmatism (rather frequent in infants) and anisometropia the problems tend to be more stringent. The early evaluation of the visual status of human infants is thus of critical importance. Photorefraction is a convenient technique for this kind of subjects. Essentially a light beam is delivered into the eyes. It is refracted by the ocular media, strikes the retina, focusing or not, reflects off and is collected by a camera. The photorefraction setup we established using new technological breakthroughs on the fields of imaging devices, digital image processing and fiber optics, allows a fast noninvasive evaluation of children visual status (refractive errors, accommodation, strabismus, ...). Results of the visual screening of a group of risk' child descents of blinds or amblyopes will be presented.

  10. 16S rRNA Gene Sequencing for Deciphering the Colorectal Cancer Gut Microbiome: Current Protocols and Workflows.

    PubMed

    Osman, Muhammad-Afiq; Neoh, Hui-Min; Ab Mutalib, Nurul-Syakima; Chin, Siok-Fong; Jamal, Rahman

    2018-01-01

    The human gut holds the densest microbiome ecosystem essential in maintaining a healthy host physiology, whereby disruption of this ecosystem has been linked to the development of colorectal cancer (CRC). The advent of next-generation sequencing technologies such as the 16S rRNA gene sequencing has enabled characterization of the CRC gut microbiome architecture in an affordable and culture-free approach. Nevertheless, the lack of standardization in handling and storage of biospecimens, nucleic acid extraction, 16S rRNA gene primer selection, length, and depth of sequencing and bioinformatics analyses have contributed to discrepancies found in various published studies of this field. Accurate characterization of the CRC microbiome found in different stages of CRC has the potential to be developed into a screening tool in the clinical setting. This mini review aims to concisely compile all available CRC microbiome studies performed till end of 2016 and to suggest standardized protocols that are crucial in developing a gut microbiome screening panel for CRC.

  11. Design of video processing and testing system based on DSP and FPGA

    NASA Astrophysics Data System (ADS)

    Xu, Hong; Lv, Jun; Chen, Xi'ai; Gong, Xuexia; Yang, Chen'na

    2007-12-01

    Based on high speed Digital Signal Processor (DSP) and Field Programmable Gate Array (FPGA), a video capture, processing and display system is presented, which is of miniaturization and low power. In this system, a triple buffering scheme was used for the capture and display, so that the application can always get a new buffer without waiting; The Digital Signal Processor has an image process ability and it can be used to test the boundary of workpiece's image. A video graduation technology is used to aim at the position which is about to be tested, also, it can enhance the system's flexibility. The character superposition technology realized by DSP is used to display the test result on the screen in character format. This system can process image information in real time, ensure test precision, and help to enhance product quality and quality management.

  12. A Model Program for Translational Medicine in Epilepsy Genetics

    PubMed Central

    Smith, Lacey A.; Ullmann, Jeremy F. P.; Olson, Heather E.; El Achkar, Christelle M.; Truglio, Gessica; Kelly, McKenna; Rosen-Sheidley, Beth; Poduri, Annapurna

    2017-01-01

    Recent technological advances in gene sequencing have led to a rapid increase in gene discovery in epilepsy. However, the ability to assess pathogenicity of variants, provide functional analysis, and develop targeted therapies has not kept pace with rapid advances in sequencing technology. Thus, although clinical genetic testing may lead to a specific molecular diagnosis for some patients, test results often lead to more questions than answers. As the field begins to focus on therapeutic applications of genetic diagnoses using precision medicine, developing processes that offer more than equivocal test results is essential. The success of precision medicine in epilepsy relies on establishing a correct genetic diagnosis, analyzing functional consequences of genetic variants, screening potential therapeutics in the preclinical laboratory setting, and initiating targeted therapy trials for patients. We describe the structure of a comprehensive, pediatric Epilepsy Genetics Program that can serve as a model for translational medicine in epilepsy. PMID:28056630

  13. Technology transfer of operator-in-the-loop simulation

    NASA Technical Reports Server (NTRS)

    Yae, K. H.; Lin, H. C.; Lin, T. C.; Frisch, H. P.

    1994-01-01

    The technology developed for operator-in-the-loop simulation in space teleoperation has been applied to Caterpillar's backhoe, wheel loader, and off-highway truck. On an SGI workstation, the simulation integrates computer modeling of kinematics and dynamics, real-time computational and visualization, and an interface with the operator through the operator's console. The console is interfaced with the workstation through an IBM-PC in which the operator's commands were digitized and sent through an RS-232 serial port. The simulation gave visual feedback adequate for the operator in the loop, with the camera's field of vision projected on a large screen in multiple view windows. The view control can emulate either stationary or moving cameras. This simulator created an innovative engineering design environment by integrating computer software and hardware with the human operator's interactions. The backhoe simulation has been adopted by Caterpillar in building a virtual reality tool for backhoe design.

  14. A Perspective on the Future of High-Throughput RNAi Screening: Will CRISPR Cut Out the Competition or Can RNAi Help Guide the Way?

    PubMed

    Taylor, Jessica; Woodcock, Simon

    2015-09-01

    For more than a decade, RNA interference (RNAi) has brought about an entirely new approach to functional genomics screening. Enabling high-throughput loss-of-function (LOF) screens against the human genome, identifying new drug targets, and significantly advancing experimental biology, RNAi is a fast, flexible technology that is compatible with existing high-throughput systems and processes; however, the recent advent of clustered regularly interspaced palindromic repeats (CRISPR)-Cas, a powerful new precise genome-editing (PGE) technology, has opened up vast possibilities for functional genomics. CRISPR-Cas is novel in its simplicity: one piece of easily engineered guide RNA (gRNA) is used to target a gene sequence, and Cas9 expression is required in the cells. The targeted double-strand break introduced by the gRNA-Cas9 complex is highly effective at removing gene expression compared to RNAi. Together with the reduced cost and complexity of CRISPR-Cas, there is the realistic opportunity to use PGE to screen for phenotypic effects in a total gene knockout background. This review summarizes the exciting development of CRISPR-Cas as a high-throughput screening tool, comparing its future potential to that of well-established RNAi screening techniques, and highlighting future challenges and opportunities within these disciplines. We conclude that the two technologies actually complement rather than compete with each other, enabling greater understanding of the genome in relation to drug discovery. © 2015 Society for Laboratory Automation and Screening.

  15. Spatial and Temporal Variations of a Screening Current Induced Magnetic Field in a Double-Pancake HTS Insert of an LTS/HTS NMR Magnet

    PubMed Central

    Ahn, Min Cheol; Yagai, Tsuyoshi; Hahn, Seungyong; Ando, Ryuya; Bascuñán, Juan; Iwasa, Yukikazu

    2010-01-01

    This paper presents experimental and simulation results of a screening current induced magnetic field (SCF) in a high temperature superconductor (HTS) insert that constitutes a low-/high-temperature superconductor (LTS/HTS) NMR magnet. In this experiment, the HTS insert, a stack of 50 double-pancake coils, each wound with Bi2223 tape, was operated at 77 K. A screening current was induced in the HTS insert by three magnetic field sources: 1) a self field from the HTS insert; 2) an external field from a 5-T background magnet; and 3) combinations of 1) and 2). For each field excitation, which induced an SCF, its axial field distribution and temporal variations were measured and compared with simulation results based on the critical state model. Agreement on field profile between experiment and simulation is satisfactory but more work is needed to make the simulation useful for designing shim coils that will cancel the SCF. PMID:20401187

  16. Demonstration of a Cylinder Fill System Based on Solid Electrolyte Oxygen Separator (SEOS) Technology: Early Field Assessment at a USAF Maintenance Facility

    DTIC Science & Technology

    2010-06-01

    to result in lower maintenance and higher reliability compared with the commercially practiced options of pressure swing adsorption (PSA) or vacuum ...screen and the temperature displayed on the graph will decrease. The Knob is used to zoom the chart and scroll through historical values. For a list of...Friday ‐ Status: OK.  Tinker AFB reported a FAL alarm occurs when the compressor isn’t  pumping  oxygen.  The FAL  alarm terminates when the

  17. Definition of experiments and instruments for a communication/navigation research laboratory. Volume 2: Experiment selection

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The selection and definition of candidate experiments and the associated experiment instrumentation requirements are described. Information is presented that addresses the following study objectives: (1) determine specific research and technology needs in the comm/nav field through a survey of the scientific/technical community; (2) develop manned low earth orbit space screening criteria and compile lists of potential candidate experiments; (3) in Blue Book format, define and describe selected candidate experiments in sufficient detail to develop laboratory configuration designs and layouts; and (4) develop experiment time phasing criteria and recommend a payload for sortie can/early laboratory missions.

  18. Multidisciplinary molecular diagnostics: the 9th European meeting on molecular diagnostics.

    PubMed

    Loonen, Anne J M; Schuurman, Rob; van den Brule, Adriaan J C

    2016-01-01

    This report presents a summary of the 9th European Meeting on Molecular Diagnostics held in Noordwijk, The Netherlands, 14-16 October 2015. This 3-day conference covered many relevant topics in the field of molecular diagnostics in humans, including infectious disease, oncology, outbreak management, population-based cancer screening, standardization and quality control, chronic diseases and pharmacogenetics. Beyond these different areas, shared values are new technologies and novel technical and clinical applications. Approximately 450 participants, the majority coming from European countries, attended the meeting. Besides high quality scientific presentations, more than 35 diagnostic companies presented their latest innovations, altogether in an informal and inspiring scientific ambience.

  19. A Review of the Application of Body-on-a-Chip for Drug Test and Its Latest Trend of Incorporating Barrier Tissue.

    PubMed

    Jin, Haoyi; Yu, Yanqiu

    2016-10-01

    High-quality preclinical bioassay models are essential for drug research and development. We reviewed the emerging body-on-a-chip technology, which serves as a promising model to overcome the limitations of traditional bioassay models, and introduced existing models of body-on-a-chip, their constitutional details, application for drug testing, and individual features of these models. We put special emphasis on the latest trend in this field of incorporating barrier tissue into body-on-a-chip and discussed several remaining challenges of current body-on-a-chip. © 2015 Society for Laboratory Automation and Screening.

  20. Botanicals for age-related diseases: from field to practice1234

    PubMed Central

    Weaver, Connie M; Barnes, Stephen; Wyss, J Michael; Kim, Helen; Morré, Dorothy M; Morré, D James; Simon, James E; Lila, Mary Ann; Janle, Elsa M; Ferruzzi, Mario G

    2009-01-01

    The Purdue–University of Alabama Botanicals Research Center for Age Related Disease joins novel technologies to study the bioavailability of bioactive polyphenolic constituents and their relation to health. Many diseases that manifest with age relate to oxidative stress and tissue damage. Our goal is to follow the fate of bioactive constituents from a complex mixture to the organ affected by the disease and relate that to a protective mechanism. Equally important is to screen commercially available botanicals for their efficacy and safety. Botanicals and their relation to bone antiresorptive capacity, cognitive function, vascular effects, and cancer are principal themes in our center. PMID:18258645

  1. Noninvasive express diagnostics of pulmonary diseases based on control of patient's gas emission using methods of IR and terahertz laser spectroscopy

    NASA Astrophysics Data System (ADS)

    Starikova, M. K.; Bulanova, A. A.; Bukreeva, E. B.; Karapuzikov, A. A.; Karapuzikov, A. I.; Kistenev, Y. V.; Klementyev, V. M.; Kolker, D. B.; Kuzmin, D. A.; Nikiforova, O. Y.; Ponomarev, Yu. N.; Sherstov, I. V.; Boyko, A. A.

    2013-11-01

    Pulmonary diseases diagnostics always occupies one of the key positions in medicine practices. A large variety of high technology methods are used today, but none of them cannot be used for early screening of pulmonary diseases. We discuss abilities of methods of IR and terahertz laser spectroscopy for noninvasive express diagnostics of pulmonary diseases on a base of analysis of absorption spectra of patient's gas emission, in particular, exhaled air. Experience in the field of approaches to experimental data analysis and hard-ware realization of gas analyzers for medical applications is also discussed.

  2. Screening fifth forces in k-essence and DBI models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brax, Philippe; Burrage, Clare; Davis, Anne-Christine, E-mail: Philippe.Brax@cea.fr, E-mail: Clare.Burrage@nottingham.ac.uk, E-mail: A.C.Davis@damtp.cam.ac.uk

    New fifth forces have not yet been detected in the laboratory or in the solar system, hence it is typically difficult to introduce new light scalar fields that would mediate such forces. In recent years it has been shown that a number of non-linear scalar field theories allow for a dynamical mechanism, such as the Vainshtein and chameleon ones, that suppresses the strength of the scalar fifth force in experimental environments. This is known as screening, however it is unclear how common screening is within non-linear scalar field theories. k-essence models are commonly studied examples of non-linear models, with DBImore » as the best motivated example, and so we ask whether these non-linearities are able to screen a scalar fifth force. We find that a Vainshtein-like screening mechanism exists for such models although with limited applicability. For instance, we cannot find a screening mechanism for DBI models. On the other hand, we construct a large class of k-essence models which lead to the acceleration of the Universe in the recent past for which the fifth force mediated by the scalar can be screened.« less

  3. Carrier screening for single gene disorders.

    PubMed

    Rose, Nancy C; Wick, Myra

    2018-04-01

    Screening for genetic disorders began in 1963 with the initiation of newborn screening for phenylketonuria. Advances in molecular technology have made both newborn screening for newborns affected with serious disorders, and carrier screening of individuals at risk for offspring with genetic disorders, more complex and more widely available. Carrier screening today can be performed secondary to family history-based screening, ethnic-based screening, and expanded carrier screening (ECS). ECS is panel-based screening, which analyzes carrier status for hundreds of genetic disorders irrespective of patient race or ethnicity. In this article, we review the historical and current aspects of carrier screening for single gene disorders, including future research directions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Disruptive Civil Technologies: Six Technologies With Potential Impacts on US Interests Out to 2025

    DTIC Science & Technology

    2008-04-01

    power (geopolitical, military, economic, or social cohesion). The six disruptive technologies were identified through a process carried out by...clustering, development of technology descriptors, screening, and prioritizing, analysts down-selected from 102 potentially disruptive technologies . They

  5. Total-body photography in skin cancer screening: the clinical utility of standardized imaging.

    PubMed

    Rosenberg, Alexandra; Meyerle, Jon H

    2017-05-01

    Early detection of skin cancer is essential to reducing morbidity and mortality from both melanoma and nonmelanoma skin cancers. Total-body skin examinations (TBSEs) may improve early detection of malignant melanomas (MMs) but are controversial due to the poor quality of data available to establish a mortality benefit from skin cancer screening. Total-body photography (TBP) promises to provide a way forward by lowering the costs of dermatologic screening while simultaneously leveraging technology to increase patient access to dermatologic care. Standardized TBP also offers the ability for dermatologists to work synergistically with modern computer technology involving algorithms capable of analyzing high-quality images to flag concerning lesions that may require closer evaluation. On a population level, inexpensive TBP has the potential to increase access to skin cancer screening and it has several specific applications in a military population. The utility of standardized TBP is reviewed in the context of skin cancer screening and teledermatology.

  6. Current controversies in prenatal diagnosis 2: Cell-free DNA prenatal screening should be used to identify all chromosome abnormalities.

    PubMed

    Chitty, Lyn S; Hudgins, Louanne; Norton, Mary E

    2018-02-01

    Noninvasive prenatal testing (NIPT) using cell-free DNA (cfDNA) from maternal serum has been clinically available since 2011. This technology has revolutionized our ability to screen for the common aneuploidies trisomy 21 (Down syndrome), trisomy 18, and trisomy 13. More recently, clinical laboratories have offered screening for other chromosome abnormalities including sex chromosome abnormalities and copy number variants (CNV) without little published data on the sensitivity, specificity, and positive predictive value. In this debate, the pros and cons of performing prenatal screening via cfDNA for all chromosome abnormalities is discussed. At the time of the debate in 2017, the general consensus was that the literature does not yet support using this technology to screen for all chromosome abnormalities and that education is key for both providers and the patients so that the decision-making process is as informed as possible. © 2018 John Wiley & Sons, Ltd.

  7. Development and evaluation of nursing user interface screens using multiple methods.

    PubMed

    Hyun, Sookyung; Johnson, Stephen B; Stetson, Peter D; Bakken, Suzanne

    2009-12-01

    Building upon the foundation of the Structured Narrative Electronic Health Record (EHR) model, we applied theory-based (combined Technology Acceptance Model and Task-Technology Fit Model) and user-centered methods to explore nurses' perceptions of functional requirements for an electronic nursing documentation system, design user interface screens reflective of the nurses' perspectives, and assess nurses' perceptions of the usability of the prototype user interface screens. The methods resulted in user interface screens that were perceived to be easy to use, potentially useful, and well-matched to nursing documentation tasks associated with Nursing Admission Assessment, Blood Administration, and Nursing Discharge Summary. The methods applied in this research may serve as a guide for others wishing to implement user-centered processes to develop or extend EHR systems. In addition, some of the insights obtained in this study may be informative to the development of safe and efficient user interface screens for nursing document templates in EHRs.

  8. An Auto-Tuning PI Control System for an Open-Circuit Low-Speed Wind Tunnel Designed for Greenhouse Technology

    PubMed Central

    Espinoza, Karlos; Valera, Diego L.; Torres, José A.; López, Alejandro; Molina-Aiz, Francisco D.

    2015-01-01

    Wind tunnels are a key experimental tool for the analysis of airflow parameters in many fields of application. Despite their great potential impact on agricultural research, few contributions have dealt with the development of automatic control systems for wind tunnels in the field of greenhouse technology. The objective of this paper is to present an automatic control system that provides precision and speed of measurement, as well as efficient data processing in low-speed wind tunnel experiments for greenhouse engineering applications. The system is based on an algorithm that identifies the system model and calculates the optimum PI controller. The validation of the system was performed on a cellulose evaporative cooling pad and on insect-proof screens to assess its response to perturbations. The control system provided an accuracy of <0.06 m·s−1 for airflow speed and <0.50 Pa for pressure drop, thus permitting the reproducibility and standardization of the tests. The proposed control system also incorporates a fully-integrated software unit that manages the tests in terms of airflow speed and pressure drop set points. PMID:26274962

  9. Extended sources near-field processing of experimental aperture synthesis data and application of the Gerchberg method for enhancing radiometric three-dimensional millimetre-wave images in security screening portals

    NASA Astrophysics Data System (ADS)

    Salmon, Neil A.

    2017-10-01

    Aperture synthesis for passive millimetre wave imaging provides a means to screen people for concealed threats in the extreme near-field configuration of a portal, a regime where the imager to subject distance is of the order of both the required depth-of-field and the field-of-view. Due to optical aberrations, focal plane array imagers cannot deliver the large depth-of-fields and field-of-views required in this regime. Active sensors on the other hand can deliver these but face challenges of illumination, speckle and multi-path issues when imaging canyon regions of the body. Fortunately an aperture synthesis passive millimetre wave imaging system can deliver large depth-of-fields and field-of-views, whilst having no speckle effects, as the radiometric emission from the human body is spatially incoherent. Furthermore, as in portal security screening scenarios the aperture synthesis imaging technique delivers a half-wavelength spatial resolution, it can effectively screen the whole of the human body. Some recent measurements are presented that demonstrate the three-dimensional imaging capability of extended sources using a 22 GHz aperture synthesis system. A comparison is made between imagery generated via the analytic Fourier transform and a gridding fast Fourier transform method. The analytic Fourier transform enables aliasing in the imagery to be more clearly identified. Some initial results are also presented of how the Gerchberg technique, an image enhancement algorithm used in radio astronomy, is adapted for three-dimensional imaging in security screening. This technique is shown to be able to improve the quality of imagery, without adding extra receivers to the imager. The requirements of a walk through security screening system for use at entrances to airport departure lounges are discussed, concluding that these can be met by an aperture synthesis imager.

  10. Effect of Display Technology on Perceived Scale of Space.

    PubMed

    Geuss, Michael N; Stefanucci, Jeanine K; Creem-Regehr, Sarah H; Thompson, William B; Mohler, Betty J

    2015-11-01

    Our goal was to evaluate the degree to which display technologies influence the perception of size in an image. Research suggests that factors such as whether an image is displayed stereoscopically, whether a user's viewpoint is tracked, and the field of view of a given display can affect users' perception of scale in the displayed image. Participants directly estimated the size of a gap by matching the distance between their hands to the gap width and judged their ability to pass unimpeded through the gap in one of five common implementations of three display technologies (two head-mounted displays [HMD] and a back-projection screen). Both measures of gap width were similar for the two HMD conditions and the back projection with stereo and tracking. For the displays without tracking, stereo and monocular conditions differed from each other, with monocular viewing showing underestimation of size. Display technologies that are capable of stereoscopic display and tracking of the user's viewpoint are beneficial as perceived size does not differ from real-world estimates. Evaluations of different display technologies are necessary as display conditions vary and the availability of different display technologies continues to grow. The findings are important to those using display technologies for research, commercial, and training purposes when it is important for the displayed image to be perceived at an intended scale. © 2015, Human Factors and Ergonomics Society.

  11. STIDP: A U.S. Department of Homeland Security program for countering explosives attacks at large public events and mass transit facilities

    NASA Astrophysics Data System (ADS)

    Knudson, Christa K.; Kemp, Michael C.; Lombardo, Nicholas J.

    2009-05-01

    The U.S. Department of Homeland Security's Standoff Technology Integration and Demonstration Program is designed to accelerate the development and integration of technologies, concepts of operations, and training to defeat explosives attacks at large public events and mass transit facilities. The program will address threats posed by suicide bombers, vehicle-borne improvised explosive devices, and leave-behind bombs. The program is focused on developing and testing explosives countermeasure architectures using commercial off-the-shelf and near-commercial standoff and remotely operated detection technologies in prototypic operational environments. An important part of the program is the integration of multiple technologies and systems to protect against a wider range of threats, improve countermeasure performance, increase the distance from the venue at which screening is conducted, and reduce staffing requirements. The program will routinely conduct tests in public venues involving successively more advanced technology, higher levels of system integration, and more complex scenarios. This paper describes the initial field test of an integrated countermeasure system that included infrared, millimeter-wave, and video analytics technologies for detecting person-borne improvised explosive devices at a public arena. The test results are being used to develop a concept for the next generation of integrated countermeasures, to refine technical and operational requirements for architectures and technologies, and engage industry and academia in solution development.

  12. STIDP: A US Department of Homeland Security program for countering explosives attacks at large public events and mass transit facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Knudson, Christa K.; Kemp, Michael C.; Lombardo, Nicholas J.

    The Department of Homeland Security’s Standoff Technology Integration and Demonstration Program is designed to accelerate the development and integration of technologies, concepts of operations, and training to prevent explosives attacks at large public events and mass transit facilities. The program will address threats posed by suicide bombers, vehicle-borne improvised explosive devices, and leave-behind bombs. The program is focused on developing and testing explosives countermeasure architectures using commercial off-the-shelf and near-commercial standoff and remotely operated detection technologies in prototypic operational environments. An important part of the program is the integration of multiple technologies and systems to protect against a wider rangemore » of threats, improve countermeasure performance, increase the distance from the venue at which screening is conducted, and reduce staffing requirements. The program will routinely conduct tests in public venues involving successively more advanced technology, higher levels of system integration, and more complex scenarios. This paper describes the initial field test of an integrated countermeasure system that included infrared, millimeter-wave, and video analytics technologies for detecting person-borne improvised explosive devices at a public arena. The test results are being used to develop a concept for the next generation of integrated countermeasures, to refine technical and operational requirements for architectures and technologies, and engage industry and academia in solution development.« less

  13. Using the scenario method in the context of health and health care--a scoping review.

    PubMed

    Vollmar, Horst Christian; Ostermann, Thomas; Redaèlli, Marcus

    2015-10-16

    The scenario technique is a method for future research and for strategic planning. Today, it includes both qualitative and quantitative elements. The aims of this scoping review are to give an overview of the application of the scenario method in the fields of health care and to make suggestions for better reporting in future scenario projects. Between January 2013 and October 2013 we conducted a systematic search in the databases Medline, Embase, PsycInfo, Eric, The Cochrane Library, Scopus, Web of Science, and Cinahl since inception for the term 'scenario(s)' in combination with other terms, e.g. method, model, and technique. Our search was not restricted by date or language. In addition, we screened the reference lists of the included articles. A total of 576 bibliographical records were screened. After removing duplicates and three rounds of screening, 41 articles covering 38 different scenario projects were included for the final analysis. Nine of the included articles addressed disease related issues, led by mental health and dementia (n = 4), and followed by cancer (n = 3). Five scenario projects focused on public health issues at an organizational level and five focused on the labor market for different health care professionals. In addition, four projects dealt with health care 'in general', four with the field of biotechnology and personalized medicine, and additional four with other technology developments. Some of the scenario projects suffered from poor reporting of methodological aspects. Despite its potential, use of the scenario method seems to be published rarely in comparison to other methods such as the Delphi-technique, at least in the field of health care. This might be due to the complexity of the methodological approach. Individual project methods and activities vary widely and are poorly reported. Improved criteria are required for reporting of scenario project methods. With improved standards and greater transparency, the scenario method will be a good tool for scientific health care planning and strategic decision-making in public health.

  14. Automated Electrophysiology Makes the Pace for Cardiac Ion Channel Safety Screening

    PubMed Central

    Möller, Clemens; Witchel, Harry

    2011-01-01

    The field of automated patch-clamp electrophysiology has emerged from the tension between the pharmaceutical industry’s need for high-throughput compound screening versus its need to be conservative due to regulatory requirements. On the one hand, hERG channel screening was increasingly requested for new chemical entities, as the correlation between blockade of the ion channel coded by hERG and torsades de pointes cardiac arrhythmia gained increasing attention. On the other hand, manual patch-clamping, typically quoted as the “gold-standard” for understanding ion channel function and modulation, was far too slow (and, consequently, too expensive) for keeping pace with the numbers of compounds submitted for hERG channel investigations from pharmaceutical R&D departments. In consequence it became more common for some pharmaceutical companies to outsource safety pharmacological investigations, with a focus on hERG channel interactions. This outsourcing has allowed those pharmaceutical companies to build up operational flexibility and greater independence from internal resources, and allowed them to obtain access to the latest technological developments that emerged in automated patch-clamp electrophysiology – much of which arose in specialized biotech companies. Assays for nearly all major cardiac ion channels are now available by automated patch-clamping using heterologous expression systems, and recently, automated action potential recordings from stem-cell derived cardiomyocytes have been demonstrated. Today, most of the large pharmaceutical companies have acquired automated electrophysiology robots and have established various automated cardiac ion channel safety screening assays on these, in addition to outsourcing parts of their needs for safety screening. PMID:22131974

  15. SCIENTIFIC AND TECHNOLOGICAL SUPPORT ON IN VITRO ASSAYS FOR THE AGENCY'S ENDOCRINE DISRUPTOR SCREENING PROGRAM

    EPA Science Inventory

    In response to the 1996 legislative mandate for an endocrine screening and testing program, we are helping develop, standardize and validate relatively sensitive, robust and relatively simple methods for in vitro screening of chemicals that affect estrogen, and androgen function ...

  16. Infant Imitation from Television Using Novel Touch Screen Technology

    ERIC Educational Resources Information Center

    Zack, Elizabeth; Barr, Rachel; Gerhardstein, Peter; Dickerson, Kelly; Meltzoff, Andrew N.

    2009-01-01

    Infants learn less from a televised demonstration than from a live demonstration, the "video deficit effect." The present study employs a novel approach, using touch screen technology to examine 15-month olds' transfer of learning. Infants were randomly assigned either to within-dimension (2D/2D or 3D/3D) or cross-dimension (3D/2D or 2D/3D)…

  17. New FOAs for using IT to support systematic screening and treatment of depression in cancer. | Informatics Technology for Cancer Research (ITCR)

    Cancer.gov

    The purpose of these Funding Opportunity Announcements (FOAs) is to identify new, information technology (IT)-enabled delivery models that support systematic screening and treatment of depression in cancer patients and test the feasibility of implementing these new delivery models in a variety of oncology practice settings, especially those serving under-served populations.

  18. Preschool Children's Exposure to Media, Technology, and Screen Time: Perspectives of Caregivers from Three Early Childcare Settings

    ERIC Educational Resources Information Center

    Sharkins, Kimberly A.; Newton, Allison B.; Albaiz, Najla Essa A.; Ernest, James M.

    2016-01-01

    Young children are being increasingly exposed to media, technology, and screen time (MeTS) at home and in instructional settings. Little is known about the long-term effects of MeTS and there is a lack of research concerning caregivers' opinions regarding young children's exposure to and utilization of MeTS. Therefore, this study explored the…

  19. Effect of anisotropic thermal transport on the resistive plasma response to resonant magnetic perturbation field

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bai, Xue; Liu, Yueqiang; Gao, Zhe

    Plasma response to the resonant magnetic perturbation (RMP) field is numerically investigated by an extended toroidal fluid model, which includes anisotropic thermal transport physics parallel and perpendicular to the total magnetic field. The thermal transport is found to be effective in eliminating the toroidal average curvature induced plasma screening (the so called Glasser-Green-Johnson, GGJ screening) at slow toroidal flow regime, whilst having minor effect on modifying the conventional plasma screening regimes at faster flow. Furthermore, this physics effect of interaction between thermal transport and GGJ screening is attributed to the modification of the radial structure of the shielding current, resultedmore » from the plasma response to the applied field. The modification of the plasma response (shielding current, response field, plasma displacement and the perturbed velocity) also has direct consequence on the toroidal torques produced by RMP. These modelling results show that thermal transport reduces the resonant electromagnetic torque as well as the torque associated with the Reynolds stress, but enhances the neoclassical toroidal viscous torque at slow plasma flow.« less

  20. Effect of anisotropic thermal transport on the resistive plasma response to resonant magnetic perturbation field

    DOE PAGES

    Bai, Xue; Liu, Yueqiang; Gao, Zhe

    2017-09-21

    Plasma response to the resonant magnetic perturbation (RMP) field is numerically investigated by an extended toroidal fluid model, which includes anisotropic thermal transport physics parallel and perpendicular to the total magnetic field. The thermal transport is found to be effective in eliminating the toroidal average curvature induced plasma screening (the so called Glasser-Green-Johnson, GGJ screening) at slow toroidal flow regime, whilst having minor effect on modifying the conventional plasma screening regimes at faster flow. Furthermore, this physics effect of interaction between thermal transport and GGJ screening is attributed to the modification of the radial structure of the shielding current, resultedmore » from the plasma response to the applied field. The modification of the plasma response (shielding current, response field, plasma displacement and the perturbed velocity) also has direct consequence on the toroidal torques produced by RMP. These modelling results show that thermal transport reduces the resonant electromagnetic torque as well as the torque associated with the Reynolds stress, but enhances the neoclassical toroidal viscous torque at slow plasma flow.« less

  1. Effect of anisotropic thermal transport on the resistive plasma response to resonant magnetic perturbation field

    NASA Astrophysics Data System (ADS)

    Bai, Xue; Liu, Yueqiang; Gao, Zhe

    2017-10-01

    Plasma response to the resonant magnetic perturbation (RMP) field is numerically investigated by an extended toroidal fluid model, which includes anisotropic thermal transport physics parallel and perpendicular to the total magnetic field. The thermal transport is found to be effective in eliminating the toroidal average curvature induced plasma screening (the so called Glasser-Green-Johnson, GGJ screening) in a slow toroidal flow regime, whilst having minor effect on modifying the conventional plasma screening regimes at faster flow. This physics effect of interaction between thermal transport and GGJ screening is attributed to the modification of the radial structure of the shielding current, which resulted from the plasma response to the applied field. The modification of the plasma response (shielding current, response field, plasma displacement, and the perturbed velocity) also has direct consequence on the toroidal torques produced by RMP. Modelling results show that thermal transport reduces the resonant electromagnetic torque as well as the torque associated with the Reynolds stress, but enhances the neoclassical toroidal viscous torque at slow plasma flow.

  2. Direct imaging of explosives.

    PubMed

    Knapp, E A; Moler, R B; Saunders, A W; Trower, W P

    2000-01-01

    Any technique that can detect nitrogen concentrations can screen for concealed explosives. However, such a technique would have to be insensitive to metal, both encasing and incidental. If images of the nitrogen concentrations could be captured, then, since form follows function, a robust screening technology could be developed. However these images would have to be sensitive to the surface densities at or below that of the nitrogen contained in buried anti-personnel mines or of the SEMTEX that brought down Pan Am 103, approximately 200 g. Although the ability to image in three-dimensions would somewhat reduce false positives, capturing collateral images of carbon and oxygen would virtually assure that nitrogenous non-explosive material like fertilizer, Melmac dinnerware, and salami could be eliminated. We are developing such an instrument, the Nitrogen Camera, which has met experimentally these criteria with the exception of providing oxygen images, which awaits the availability of a sufficiently energetic light source. Our Nitrogen Camera technique uses an electron accelerator to produce photonuclear reactions whose unique decays it registers. Clearly if our Nitrogen Camera is made mobile, it could be effective in detecting buried mines, either in an active battlefield situation or in the clearing of abandoned military munitions. Combat operations require that a swathe the width of an armored vehicle, 5 miles deep, be screened in an hour, which is within our camera's scanning speed. Detecting abandoned munitions is technically easier as it is free from the onerous speed requirement. We describe here our Nitrogen Camera and show its 180 pixel intensity images of elemental nitrogen in a 200 g mine simulant and in a 125 g stick of SEMTEX. We also report on our progress in creating a lorry transportable 70 MeV electron racetrack microtron, the principal enabling technology that will allow our Nitrogen Camera to be deployed in the field.

  3. SOGC clinical practice guidelines: Substance use in pregnancy: no. 256, April 2011.

    PubMed

    Wong, Suzanne; Ordean, Alice; Kahan, Meldon

    2011-08-01

    To improve awareness and knowledge of problematic substance use in pregnancy and to provide evidence-based recommendations for the management of this challenging clinical issue for all health care providers. This guideline reviews the use of screening tools, general approach to care, and recommendations for clinical management of problematic substance use in pregnancy. Evidence-based recommendations for screening and management of problematic substance use during pregnancy and lactation. Medline, PubMed, CINAHL, and The Cochrane Library were searched for articles published from 1950 using the following key words: substance-related disorders, mass screening, pregnancy complications, pregnancy, prenatal care, cocaine, cannabis, methadone, opioid, tobacco, nicotine, solvents, hallucinogens, and amphetamines. Results were initially restricted to systematic reviews and randomized control trials/controlled clinical trials. A subsequent search for observational studies was also conducted because there are few RCTs in this field of study. Articles were restricted to human studies published in English. Additional articles were located by hand searching through article reference lists. Searches were updated on a regular basis and incorporated in the guideline up to December 2009. Grey (unpublished) literature was also identified through searching the websites of health technology assessment and health technology assessment-related agencies, clinical practice guideline collections, clinical trial registries, and national and international medical specialty societies. The quality of evidence was rated using the criteria described in the Report of the Canadian Task Force on the Preventive Health Care. Recommendations for practice were ranked according to the method described in that report (Table 1). This guideline is intended to increase the knowledge and comfort level of health care providers caring for pregnant women who have substance use disorders. Improved access to health care and assistance with appropriate addiction care leads to reduced health care costs and decreased maternal and neonatal morbidity and mortality.

  4. Field test of on-site drug detection devices

    DOT National Transportation Integrated Search

    2000-10-01

    This NHTSA-sponsored study reports the findings of a field evaluation of five on-site drug screening devices used by law enforcement to screen for illicit drugs among drivers suspected of driving under the influence (DUI) of alcohol or other drugs. I...

  5. DEMONSTRATION BULLETIN: FIELD ANALYTICAL SCREENING PROGRAM: PCB METHOD - U.S. ENVIRONMENTAL PROTECTION AGENCY

    EPA Science Inventory

    The field analytical screening program (FASP) polychlorinated biphenyl (PCB) method uses a temperature-programmable gas chromatograph (GC) equipped with an electron capture detector (ECD) to identify and quantify PCBs. Gas chromatography is an EPA-approved method for determi...

  6. Responsible implementation of expanded carrier screening

    PubMed Central

    Henneman, Lidewij; Borry, Pascal; Chokoshvili, Davit; Cornel, Martina C; van El, Carla G; Forzano, Francesca; Hall, Alison; Howard, Heidi C; Janssens, Sandra; Kayserili, Hülya; Lakeman, Phillis; Lucassen, Anneke; Metcalfe, Sylvia A; Vidmar, Lovro; de Wert, Guido; Dondorp, Wybo J; Peterlin, Borut

    2016-01-01

    This document of the European Society of Human Genetics contains recommendations regarding responsible implementation of expanded carrier screening. Carrier screening is defined here as the detection of carrier status of recessive diseases in couples or persons who do not have an a priori increased risk of being a carrier based on their or their partners' personal or family history. Expanded carrier screening offers carrier screening for multiple autosomal and X-linked recessive disorders, facilitated by new genetic testing technologies, and allows testing of individuals regardless of ancestry or geographic origin. Carrier screening aims to identify couples who have an increased risk of having an affected child in order to facilitate informed reproductive decision making. In previous decades, carrier screening was typically performed for one or few relatively common recessive disorders associated with significant morbidity, reduced life-expectancy and often because of a considerable higher carrier frequency in a specific population for certain diseases. New genetic testing technologies enable the expansion of screening to multiple conditions, genes or sequence variants. Expanded carrier screening panels that have been introduced to date have been advertised and offered to health care professionals and the public on a commercial basis. This document discusses the challenges that expanded carrier screening might pose in the context of the lessons learnt from decades of population-based carrier screening and in the context of existing screening criteria. It aims to contribute to the public and professional discussion and to arrive at better clinical and laboratory practice guidelines. PMID:26980105

  7. Taking transgenic rice drought screening to the field.

    PubMed

    Gaudin, Amélie C M; Henry, Amelia; Sparks, Adam H; Slamet-Loedin, Inez H

    2013-01-01

    Numerous transgenes have been reported to increase rice drought resistance, mostly in small-scale experiments under vegetative-stage drought stress, but few studies have included grain yield or field evaluations. Different definitions of drought resistance are currently in use for field-based and laboratory evaluations of transgenics, the former emphasizing plant responses that may not be linked to yield under drought. Although those fundamental studies use efficient protocols to uncover and validate gene functions, screening conditions differ greatly from field drought environments where the onset of drought stress symptoms is slow (2-3 weeks). Simplified screening methods, including severely stressed survival studies, are therefore not likely to identify transgenic events with better yield performance under drought in the target environment. As biosafety regulations are becoming established to allow field trials in some rice-producing countries, there is a need to develop relevant screening procedures that scale from preliminary event selection to greenhouse and field trials. Multilocation testing in a range of drought environments may reveal that different transgenes are necessary for different types of drought-prone field conditions. We describe here a pipeline to improve the selection efficiency and reproducibility of results across drought treatments and test the potential of transgenic rice for the development of drought-resistant material for agricultural purposes.

  8. Automatic detection of diabetic retinopathy features in ultra-wide field retinal images

    NASA Astrophysics Data System (ADS)

    Levenkova, Anastasia; Sowmya, Arcot; Kalloniatis, Michael; Ly, Angelica; Ho, Arthur

    2017-03-01

    Diabetic retinopathy (DR) is a major cause of irreversible vision loss. DR screening relies on retinal clinical signs (features). Opportunities for computer-aided DR feature detection have emerged with the development of Ultra-WideField (UWF) digital scanning laser technology. UWF imaging covers 82% greater retinal area (200°), against 45° in conventional cameras3 , allowing more clinically relevant retinopathy to be detected4 . UWF images also provide a high resolution of 3078 x 2702 pixels. Currently DR screening uses 7 overlapping conventional fundus images, and the UWF images provide similar results1,4. However, in 40% of cases, more retinopathy was found outside the 7-field ETDRS) fields by UWF and in 10% of cases, retinopathy was reclassified as more severe4 . This is because UWF imaging allows examination of both the central retina and more peripheral regions, with the latter implicated in DR6 . We have developed an algorithm for automatic recognition of DR features, including bright (cotton wool spots and exudates) and dark lesions (microaneurysms and blot, dot and flame haemorrhages) in UWF images. The algorithm extracts features from grayscale (green "red-free" laser light) and colour-composite UWF images, including intensity, Histogram-of-Gradient and Local binary patterns. Pixel-based classification is performed with three different classifiers. The main contribution is the automatic detection of DR features in the peripheral retina. The method is evaluated by leave-one-out cross-validation on 25 UWF retinal images with 167 bright lesions, and 61 other images with 1089 dark lesions. The SVM classifier performs best with AUC of 94.4% / 95.31% for bright / dark lesions.

  9. Site Characterization Technologies for DNAPL Investigations

    EPA Pesticide Factsheets

    This document is intended to help managers at sites with potential or confirmed DNAPL contamination identify suitable characterization technologies, screen the technologies for potential application, learn about applications at similar sites, and...

  10. Catalyst Development for Hydrogen Peroxide Rocket Engines

    NASA Technical Reports Server (NTRS)

    Morlan, P. W.; Wu, P.-K.; Ruttle, D. W.; Fuller, R. P.; Nejad, A. S.; Anderson, W. E.

    1999-01-01

    The development of various catalysts of hydrogen peroxide was conducted for the applications of liquid rocket engines. The catalyst development includes silver screen technology, solid catalyst technology, and homogeneous catalyst technology. The silver screen technology development was performed with 85% (by weight) hydrogen peroxide. The results of this investigation were used as the basis for the catalyst design of a pressure-fed liquid-fueled upper stage engine. Both silver-plated nickel 200 screens and pure silver screens were used as the active metal catalyst during the investigation, The data indicate that a high decomposition efficiency (greater than 90%) of 85% hydrogen peroxide can be achieved at a bed loading of 0.5 lbm/sq in/sec with both pure silver and silver plated screens. Samarium oxide coating, however, was found to retard the decomposition process and the catalyst bed was flooded at lower bed loading. A throughput of 200 lbm of hydrogen peroxide (1000 second run time) was tested to evaluate the catalyst aging issue and performance degradation was observed starting at approximately 400 seconds. Catalyst beds of 3.5 inch in diameter was fabricated using the same configuration for a 1,000-lbf rocket engine. High decomposition efficiency was obtained with a low pressure drop across the bed. Solid catalyst using precious metal was also developed for the decomposition of hydrogen peroxide from 85% to 98% by weight. Preliminary results show that the catalyst has a strong reactivity even after 15 minutes of peroxide decomposition. The development effort also includes the homogeneous catalyst technology. Various non-toxic catalysts were evaluated with 98% peroxide and hydrocarbon fuels. The results of open cup drop tests indicate an ignition delay around 11 ms.

  11. Printed organo-functionalized graphene for biosensing applications.

    PubMed

    Wisitsoraat, A; Mensing, J Ph; Karuwan, C; Sriprachuabwong, C; Jaruwongrungsee, K; Phokharatkul, D; Daniels, T M; Liewhiran, C; Tuantranont, A

    2017-01-15

    Graphene is a highly promising material for biosensors due to its excellent physical and chemical properties which facilitate electron transfer between the active locales of enzymes or other biomaterials and a transducer surface. Printing technology has recently emerged as a low-cost and practical method for fabrication of flexible and disposable electronics devices. The combination of these technologies is promising for the production and commercialization of low cost sensors. In this review, recent developments in organo-functionalized graphene and printed biosensor technologies are comprehensively covered. Firstly, various methods for printing graphene-based fluids on different substrates are discussed. Secondly, different graphene-based ink materials and preparation methods are described. Lastly, biosensing performances of printed or printable graphene-based electrochemical and field effect transistor sensors for some important analytes are elaborated. The reported printed graphene based sensors exhibit promising properties with good reliability suitable for commercial applications. Among most reports, only a few printed graphene-based biosensors including screen-printed oxidase-functionalized graphene biosensor have been demonstrated. The technology is still at early stage but rapidly growing and will earn great attention in the near future due to increasing demand of low-cost and disposable biosensors. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Comparative analysis of RNAi screening technologies at genome-scale reveals an inherent processing inefficiency of the plasmid-based shRNA hairpin.

    PubMed

    Bhinder, Bhavneet; Shum, David; Djaballah, Hakim

    2014-02-01

    RNAi screening in combination with the genome-sequencing projects would constitute the Holy Grail of modern genetics; enabling discovery and validation towards a better understanding of fundamental biology leading to novel targets to combat disease. Hit discordance at inter-screen level together with the lack of reproducibility is emerging as the technology's main pitfalls. To examine some of the underlining factors leading to such discrepancies, we reasoned that perhaps there is an inherent difference in knockdown efficiency of the various RNAi technologies. For this purpose, we utilized the two most popular ones, chemically synthesized siRNA duplex and plasmid-based shRNA hairpin, in order to perform a head to head comparison. Using a previously developed gain-of-function assay probing modulators of the miRNA biogenesis pathway, we first executed on a siRNA screen against the Silencer Select V4.0 library (AMB) nominating 1,273, followed by an shRNA screen against the TRC1 library (TRC1) nominating 497 gene candidates. We observed a poor overlap of only 29 hits given that there are 15,068 overlapping genes between the two libraries; with DROSHA as the only common hit out of the seven known core miRNA biogenesis genes. Distinct genes interacting with the same biogenesis regulators were observed in both screens, with a dismal cross-network overlap of only 3 genes (DROSHA, TGFBR1, and DIS3). Taken together, our study demonstrates differential knockdown activities between the two technologies, possibly due to the inefficient intracellular processing and potential cell-type specificity determinants in generating intended targeting sequences for the plasmid-based shRNA hairpins; and suggests this observed inefficiency as potential culprit in addressing the lack of reproducibility.

  13. Screening Procedures Used to Identify Children with Hearing Loss.

    ERIC Educational Resources Information Center

    Barringer, Donald G.; And Others

    1993-01-01

    Analysis of data on 1,404 young children with hearing losses indicated that 80% of the children were identified via informal hearing-screening procedures, such as parental suspicion and referral. Auditory brainstem response technology provided the lowest mean identification age. The study concludes that formal screening programs are not locating…

  14. Field-based evaluations of horizontal flat-plate fish screens

    USGS Publications Warehouse

    Rose, B.P.; Mesa, M.G.; Barbin-Zydlewski, G.

    2008-01-01

    Diversions from streams are often screened to prevent the loss of or injury to fish. Hydraulic criteria meant to protect fish that encounter screens have been developed, but primarily for screens that are vertical to the water flow rather than horizontal. For this reason, we measured selected hydraulic variables and released wild rainbow trout Oncorhynchus mykiss over two types of horizontal flat-plate fish screens in the field. Our goal was to assess the efficacy of these screens under a variety of conditions in the field and provide information that could be used to develop criteria for safe fish passage. We evaluated three different invertedweir screens over a range of stream (0.24-1.77 m3/s) and diversion flows (0.10-0.31 m3/s). Approach velocities (AVs) ranged from 3 to 8 cm/s and sweeping velocities (SVs) from 69 to 143 cm/s. We also evaluated a simple backwatered screen over stream flows of 0.23-0.79 m3/s and diversion flows of 0.08-0.32 m3/s. The mean SVs for this screen ranged from 15 to 66 cm/s and the mean AVs from 1 to 5 cm/s. The survival rates of fish held for 24 h after passage over these screens exceeded 98%. Overall, the number of fish-screen contacts was low and the injuries related to passage were infrequent and consisted primarily of minor fin injuries. Our results indicate that screens of this type have great potential as safe and effective fish screens for small diversions. Care must be taken, however, to avoid operating conditions that produce shallow or no water over the screen surface, situations of high AVs and low SVs at backwatered screens, and situations producing a localized high AV with spiraling flow. ?? Copyright by the American Fisheries Society 2008.

  15. Field trial of a synthetic tsetse-repellent technology developed for the control of bovine trypanosomosis in Kenya.

    PubMed

    Bett, B; Randolph, T F; Irungu, P; Nyamwaro, S O; Kitala, P; Gathuma, J; Grace, D; Vale, G; Hargrove, J; McDermott, J

    2010-12-01

    We conducted a field trial among Maasai cattle-keepers in Nkuruman and Nkineji areas of Kenya to evaluate the effectiveness of a synthetic tsetse-repellent technology developed for the control of trypanosomosis in cattle. The technology was a repellent (2-methoxy 4-methylphenol) emitted from dispensers attached to collars worn by cattle. Treatment was allocated at the herd level to ensure adequate protection of all the animals in a herd, with measurements of effectiveness conducted at the individual-animal level. The trial began in April 2005 and ran for 16 months including a baseline phase of 4 months. We recruited 12 herds in each area using a restricted random-sampling technique and distributed them equally into intervention (repellent) and control groups. Sample size was determined using a formal power calculation. Effectiveness or minimal worthwhile difference was defined as a 50% reduction in the incidence of trypanosome infection in the treated versus control group (effectiveness below which the technology was considered by experts as not viable compared to existing control techniques). All the animals in the recruited herds were screened monthly (buffy-coat technique) for trypanosome infections. The analysis followed the principle of intention-to-treat by which subjects are analysed according to their initial treatment assignment, regardless of the mechanical performance of the device. Crude and adjusted effects of the technology were 23% (p<0.001) and 18% (p=0.08) reduction in the infection incidence in the treatment compared to the control groups, respectively. The impact of the technology estimated in this study did not achieve the threshold of 50% reduction in the trypanosome infection incidence set a priori to indicate effectiveness (p<0.001). We therefore concluded that the prototype repellent technology package was not sufficiently effective in reducing trypanosome infection incidence under natural tsetse challenge to merit commercial development. Copyright © 2010 Elsevier B.V. All rights reserved.

  16. From Bombs to Breast Cancer Imaging: Los Alamos National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martineau, Rebecca M

    In the United States, one in eight women will be affected by breast cancer. According to the American Cancer Society, breast cancer is the most commonly diagnosed - as well as the second most fatal - cancer in American women. It is estimated that there will be nearly 200,000 diagnoses of breast cancer this year; more than 40,000 of these will be fatal. Although advances in medical technologies have greatly increased the odds of surviving the disease, the increase in screenings has not resulted in a significant reduction in the breast cancer mortality rate. Moreover, recent studies have even suggestedmore » that an increase in these methods might, in itself, cause cancer. A new tool for early detection and diagnosis of breast cancer, supported by an award from the Breast Cancer Research Program (BCRP) of the Congressionally Directed Medical Research Programs of Department of Defense, could give women a new advantage in the fight against breast cancer. This LANL-led project will integrate ultrasound tomography (UST) with recent discoveries in the field of cell and tissue biomechanics to improve breast cancer detection and characterization. UST uses ultrasound waves instead of X-rays to identify and characterize breast tumors. This technology reveals small mechanical-property changes within the breast. These changes are often the earliest signs of breast cancer. Additionally, UST is effective for women with dense breast tissue, who have a higher risk of developing breast cancer. Because the technology does not use radiation, UST can also be used as frequently as needed for women with a high risk of developing breast cancer. In contrast, mammography, the only routine breast-cancer screening tool currently available, is not effective for women with dense breast tissue and may come with unwanted side-effects caused by ionizing radiation. UST has great potential to become an alternative breast-cancer screening tool because of UST's advantages and benefits over mammography. Currently, there is fierce debate surrounding the age at which breast cancer screening should begin, and once begun, how often it should occur. The American Cancer Society recommends yearly mammograms starting at age 40. On the other hand, the U.S. Preventive Services Task Force recommends against routine so early. Rather, the Task Force recommends biennial mammography screening for women aged 50 to 74 years. The ten-year discrepancy in the onset of screening results from recent data suggesting that the frequent use of X-ray radiation during screenings could potentially increase the likelihood of developing cancer. This danger is increased by the low sensitivity and accuracy of mammograms, which sometimes require multiple screenings to yield results. Furthermore, mammograms are often not only inaccurate, but average appalling misdiagnoses rates: about 80% false positives and 15% false negatives. These misdiagnoses lead to unwarranted biopsies at an estimated health care cost of $2 billion per year, while at the same time, resulting in excessive cases of undetected cancer. As such, the National Cancer Institute recommends more studies on the advantages of types and frequency of screenings, as well as alternative screening options. The UST technology developed at LANL could be an alternative option to greatly improve the specificity and sensitivity of breast cancer screening without using ionizing radiation. LANL is developing high-resolution ultrasound tomography algorithms and a clinical ultrasound tomography scanner to conduct patient studies at the UNM Hospital. During UST scanning, the patient lies face-down while her breast, immersed in a tank of warm water, is scanned by phased-transducer arrays. UST uses recorded ultrasound signals to reconstruct a high-resolution three-dimensional image of the breast, showing the spatial distribution of mechanical properties within the breast. Breast cancers are detected by higher values of mechanical properties compared to surrounding tissues. Thus, high-resolution breast images obtained using LANL's novel UST algorithms have the potential to detect breast cancer at its earliest stage. The goal of this Multi-Team Award project is two-fold: (1) develop a novel, safe and cost-effective breast-imaging technique, and (2) improve the specificity and sensitivity of breast cancer imaging. The project is expected to integrate basic research with clinical studies, perform substantive cross-disciplinary training among scientists on the teams and involve participation of consumer advocates. Those involved in the project are optimistic about future developments.« less

  17. iPads in Breast Imaging – A Phantom Study

    PubMed Central

    Hammon, M.; Schlechtweg, P. M.; Schulz-Wendtland, R.; Uder, M.; Schwab, S. A.

    2014-01-01

    Introduction: Modern tablet PCs as the iPad are becoming more and more integrated into medicine. The aim of this study was to evaluate the display quality of iPads regarding digital mammography. Materials and Methods: Three experienced readers compared the display quality of the iPad 2 and 3 with a dedicated 10 megapixel (MP) mammography liquid crystal display (LCD) screen in consensus using the standardized Contrast Detail Mammography (CDMAM) phantom. Phantom fields without agreement between the readers were classified as “uncertain”, correct 2 : 1 decisions were classified as “uncertain/readable”. In a second step display quality of the three reading devices was judged subjectively in a side by side comparison. Results: The 10 MP screen was superior to both iPads in 4 (phantom-)fields and inferior in 2 fields. Comparing the iPads, version 3 was superior in 4 fields and version 2 was superior in 1 field. However these differences were not significant. Total number of “uncertain” fields did not show significant differences. The number of “uncertain” fields was 15 with the 10 MP screen, 16 with the iPad 2 and 17 with the iPad 3 (p > 0.05), the number of “uncertain/readable” fields was 4, 7 and 8, respectively. Subjective image quality of the iPad 3 and the 10 MP screen was rated superior to the iPad 2. Conclusion: The evaluated iPads, especially in version 3, seem to be adequate to display mammograms in a diagnostic quality and thus could be useful e.g. for patient consultation, clinical demonstration or educational and teaching purposes. However primary mammogram reading should still be performed on dedicated large sized reading screens. PMID:24741126

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burrage, Clare; Copeland, Edmund J.; Hinds, E.A., E-mail: Clare.Burrage@nottingham.ac.uk, E-mail: Edmund.Copeland@nottingham.ac.uk, E-mail: Ed.Hinds@imperial.ac.uk

    Theories of dark energy require a screening mechanism to explain why the associated scalar fields do not mediate observable long range fifth forces. The archetype of this is the chameleon field. Here we show that individual atoms are too small to screen the chameleon field inside a large high-vacuum chamber, and therefore can detect the field with high sensitivity. We derive new limits on the chameleon parameters from existing experiments, and show that most of the remaining chameleon parameter space is readily accessible using atom interferometry.

  19. Applications of Biophysics in High-Throughput Screening Hit Validation.

    PubMed

    Genick, Christine Clougherty; Barlier, Danielle; Monna, Dominique; Brunner, Reto; Bé, Céline; Scheufler, Clemens; Ottl, Johannes

    2014-06-01

    For approximately a decade, biophysical methods have been used to validate positive hits selected from high-throughput screening (HTS) campaigns with the goal to verify binding interactions using label-free assays. By applying label-free readouts, screen artifacts created by compound interference and fluorescence are discovered, enabling further characterization of the hits for their target specificity and selectivity. The use of several biophysical methods to extract this type of high-content information is required to prevent the promotion of false positives to the next level of hit validation and to select the best candidates for further chemical optimization. The typical technologies applied in this arena include dynamic light scattering, turbidometry, resonance waveguide, surface plasmon resonance, differential scanning fluorimetry, mass spectrometry, and others. Each technology can provide different types of information to enable the characterization of the binding interaction. Thus, these technologies can be incorporated in a hit-validation strategy not only according to the profile of chemical matter that is desired by the medicinal chemists, but also in a manner that is in agreement with the target protein's amenability to the screening format. Here, we present the results of screening strategies using biophysics with the objective to evaluate the approaches, discuss the advantages and challenges, and summarize the benefits in reference to lead discovery. In summary, the biophysics screens presented here demonstrated various hit rates from a list of ~2000 preselected, IC50-validated hits from HTS (an IC50 is the inhibitor concentration at which 50% inhibition of activity is observed). There are several lessons learned from these biophysical screens, which will be discussed in this article. © 2014 Society for Laboratory Automation and Screening.

  20. FIELD SCREENING METHODS FOR HAZARDOUS WASTES AND TOXIC CHEMICALS

    EPA Science Inventory

    The purpose of this document is to present the technical papers that were presented at the Second International Symposium on Field Screening Methods for Hazardous Wastes and Toxic Chemicals. ixty platform presentations were made and included in one of ten sessions: hemical sensor...

  1. [The QR code in society, economy and medicine--fields of application, options and chances].

    PubMed

    Flaig, Benno; Parzeller, Markus

    2011-01-01

    2D codes like the QR Code ("Quick Response") are becoming more and more common in society and medicine. The application spectrum and benefits in medicine and other fields are described. 2D codes can be created free of charge on any computer with internet access without any previous knowledge. The codes can be easily used in publications, presentations, on business cards and posters. Editors choose between contact details, text or a hyperlink as information behind the code. At expert conferences, linkage by QR Code allows the audience to download presentations and posters quickly. The documents obtained can then be saved, printed, processed etc. Fast access to stored data in the internet makes it possible to integrate additional and explanatory multilingual videos into medical posters. In this context, a combination of different technologies (printed handout, QR Code and screen) may be reasonable.

  2. KSC-99pp0277

    NASA Image and Video Library

    1999-03-06

    During the 1999 FIRST Southeastern Regional robotic competition held at KSC, a robot carrying its cache of pillow-like disks maneuvers to move around another at left. Powered by 12-volt batteries and operated by remote control, the robotic gladiators spend two minutes each trying to grab, claw and hoist the pillows onto their machines. Teams play defense by taking away competitors' pillows and generally harassing opposing machines. Behind the field are a group of judges, including KSC former KSC Director of Shuttle Processing Robert Sieck (left, in cap), and Center Director Roy Bridges (in white shirt). A giant screen TV in the background displays the action on the playing field. FIRST is a nonprofit organization, For Inspiration and Recognition of Science and Technology. The competition comprised 27 teams, pairing high school students with engineer mentors and corporations. The FIRST robotics competition is designed to provide students with a hands-on, inside look at engineering and other professional careers

  3. Post waterflood CO{sub 2} miscible flood in light oil, fluvial-dominated deltaic reservoir. FY 1993 annual report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, D.W.

    1995-03-01

    The project is a Class 1 DOE-sponsored field demonstration project of a CO{sub 2} miscible flood project at the Port Neches Field in Orange County, Texas. The project will determine the recovery efficiency of CO{sub 2} flooding a waterflooded and a partial waterdrive sandstone reservoir at a depth of 5,800. The project will also evaluate the use of a horizontal CO{sub 2} injection well placed at the original oil-water contact of the waterflooded reservoir. A PC-based reservoir screening model will be developed by Texaco`s research lab in Houston and Louisiana State University will assist in the development of a databasemore » of fluvial-dominated deltaic reservoirs where CO{sub 2} flooding may be applicable. This technology will be transferred throughout the oil industry through a series of technical papers and industry open forums.« less

  4. Commercial and industrial applications of color ink jet: a technological perspective

    NASA Astrophysics Data System (ADS)

    Dunand, Alain

    1996-03-01

    In just 5 years, color ink-jet has become the dominant technology for printing color images and graphics in the office and home markets. In commercial printing, the traditional printing processes are being influenced by new digital techniques. Color ink-jet proofing, and concepts such as computer to film/plate or digital processes are contributing to the evolution of the industry. In industrial color printing, the penetration of digital techniques is just beginning. All widely used conventional contact printing technologies involve mechanical printing forms including plates, screens or engraved cylinders. Such forms, which need to be newly created and set up for each job, increase costs. In our era of fast changing customer demands, growing needs for customization, and increasing use of digital exchange of information, the commercial and industrial printing markets represent an enormous potential for digital printing technologies. The adoption characteristics for the use of color ink-jet in these industries are discussed. Examples of color ink-jet applications in the fields of billboard printing, floor/wall covering decoration, and textile printing are described. The requirements on print quality, productivity, reliability, substrate compatibility, and color lead to the consideration of various types of ink-jet technologies. Key technical enabling factors and directions for future improvements are presented.

  5. The shape dependence of chameleon screening

    NASA Astrophysics Data System (ADS)

    Burrage, Clare; Copeland, Edmund J.; Moss, Adam; Stevenson, James A.

    2018-01-01

    Chameleon scalar fields can screen their associated fifth forces from detection by changing their mass with the local density. These models are an archetypal example of a screening mechanism, and have become an important target for both cosmological surveys and terrestrial experiments. In particular there has been much recent interest in searching for chameleon fifth forces in the laboratory. It is known that the chameleon force is less screened around non-spherical sources, but only the field profiles around a few simple shapes are known analytically. In this work we introduce a numerical code that solves for the chameleon field around arbitrary shapes with azimuthal symmetry placed in a spherical vacuum chamber. We find that deviations from spherical symmetry can increase the chameleon acceleration experienced by a test particle, and that the least screened objects are those which minimize some internal dimension. For the shapes considered in this work, keeping the mass, density and background environment fixed, the accelerations due to the source varied by a factor of ~ 3.

  6. Neonatal screening for inborn errors of metabolism: cost, yield and outcome.

    PubMed

    Pollitt, R J; Green, A; McCabe, C J; Booth, A; Cooper, N J; Leonard, J V; Nicholl, J; Nicholson, P; Tunaley, J R; Virdi, N K

    1997-01-01

    OBJECTIVES. To systematically review the literature on inborn errors of metabolism, neonatal screening technology and screening programmes in order to analyse the costs and benefits of introducing screening based on tandem mass-spectrometry (tandem MS) for a wide range of disorders of amino acid and organic acid metabolism in the UK. To evaluate screening for cystic fibrosis, Duchenne muscular dystrophy and other disorders which are tested on an individual basis. HOW THE RESEARCH WAS CONDUCTED. Systematic searches were carried out of the literature on inborn errors of metabolism, neonatal screening programmes, tandem MS-based neonatal screening technology, economic evaluations of neonatal screening programmes and psychological aspects of neonatal screening. Background material on the biology of inherited metabolic disease, the basic philosophy, and the history and current status of the UK screening programme was also collected. Relevant papers in the grey literature and recent publications were identified by hand-searching. Each paper was graded. For each disease an aggregate grade for the state of knowledge in six key areas was awarded. Additional data were prospectively collected on activity and costs in UK neonatal screening laboratories, and expert clinical opinion on current treatment modalities and outcomes. These data were used to construct a decision-analysis model of neonatal screening technologies, comparing tandem MS with the existing phenylketonuria screening methods. This model determined the cost per additional case identified and, for each disease, the additional treatment costs per case, and the cost per life-year saved. All costs and benefits were discounted at 6% per annum. One-way sensitivity analysis was performed showing the effect of varying the discount rate, the incidence rate of each disorder, the number of neonates screened and the cost of tandem MS, on the cost per life-year gained. RESEARCH FINDINGS. The UK screening programmes for phenylketonuria and congenital hypothyroidism have largely achieved the expected objectives and are cost-effective. Current concerns are the difficulty of maintaining adequate coverage, perceived organisational weaknesses, and a lack of overview. For many of the organic acid disorders it was necessary to rely on data obtained from clinically-diagnosed cases. Many of these diseases can be treated very effectively and a sensitive screening test was available for most of the diseases. Except for cystic fibrosis, there have been no randomised controlled trials of the overall effectiveness of neonatal screening. Despite the anxiety generated by the screening process, there is strong parental support for screening. The effects of diagnosis through screening on subsequent reproductive behaviour is less clear. Conflicts exist between current concepts and the traditional principles of screening. The availability of effective treatment is not an absolute prerequisite: early diagnosis is of value to the family concerned and, to the extent that is leads to increased use of prenatal diagnosis, may help to reduce the overall burden of disease. Neonatal screening is also of value in diseases which present early but with non-specific symptoms. Indeed, almost all of the diseases considered could merit neonatal screening. The majority of economic evaluations failed to incorporate the health benefits from screening, and therefore failed to address the value of the information which the screening programmes provided to parents. The marginal cost of changing from present technology to tandem MS would be approximately 0.60 pounds per baby at a workload of 100,000 samples a year, and 0.87 pounds at 50,000 samples per year. The ability to screen for a wider range of diseases would lead to the identification of some 20 additional cases per 100,000 infants screened, giving a laboratory cost per additional diagnosis of 3000 pounds at an annual workload of 100,000 babies per year.(ABSTRACT TRUNCATED)

  7. Separation of organic ion exchange resins from sludge -- engineering study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duncan, J.B.

    1998-08-25

    This engineering study evaluates the use of physical separation technologies to separate organic ion exchange resin from KE Basin sludge prior to nitric acid dissolution. This separation is necessitate to prevent nitration of the organics in the acid dissolver. The technologies under consideration are: screening, sedimentation, elutriation. The recommended approach is to first screen the Sludge and resin 300 microns then subject the 300 microns plus material to elutriation.

  8. Miniature and Molecularly Specific Optical Screening Technologies for Breast Cancer

    DTIC Science & Technology

    2007-10-01

    AD_________________ Award Number: W81XWH-05-1-0363 TITLE: Minature and Molecularly Specific...Annual 3. DATES COVERED (From - To) 1 SEP 2006 - 31 AUG 2007 4. TITLE AND SUBTITLE Minature and Molecularly Specific Optical Screening Technologies...area with a hole drilled in the center of the detector. P4-1 has a 600 μm diameter fiber fitted through the hole in the center of the detector while

  9. Newborn Screening for Lysosomal Storage Disorders

    PubMed Central

    Peake, Roy W. A.; Bodamer, Olaf A.

    2016-01-01

    Newborn screening is one of the most important public health initiatives to date, focusing on the identification of presymptomatic newborn infants with treatable conditions to reduce morbidity and mortality. The number of screening conditions continues to expand due to advances in screening technologies and the development of novel therapies. Consequently, some of the lysosomal storage disorders are now considered as candidates for newborn screening, although many challenges including identification of late-onset phenotypes remain. This review provides a critical appraisal of the current state of newborn screening for lysosomal storage disorders. PMID:28180027

  10. [Progresses in screening active compounds from herbal medicine by affinity chromatography].

    PubMed

    Feng, Ying-shu; Tong, Shan-shan; Xu, Xi-ming; Yu, Jiang-nan

    2015-03-01

    Affinity chromatography is a chromatographic method for separating molecules using the binding characteristics of the stationary phase with potential drug molecules. This method can be performed as a high throughput screening method and a chromatographic separation method to screen a variety of active drugs. This paper summarizes the history of affinity chromatography, screening technology of affinity chromatography, and application of affinity chromatography in screening bio-active compounds in herbal medicines, and then discusses its application prospects, in order to broaden applications of the affinity chromatography in drug screening.

  11. Organ-on-chip models of cancer metastasis for future personalized medicine: From chip to the patient.

    PubMed

    Caballero, D; Kaushik, S; Correlo, V M; Oliveira, J M; Reis, R L; Kundu, S C

    2017-12-01

    Most cancer patients do not die from the primary tumor but from its metastasis. Current in vitro and in vivo cancer models are incapable of satisfactorily predicting the outcome of various clinical treatments on patients. This is seen as a serious limitation and efforts are underway to develop a new generation of highly predictive cancer models with advanced capabilities. In this regard, organ-on-chip models of cancer metastasis emerge as powerful predictors of disease progression. They offer physiological-like conditions where the (hypothesized) mechanistic determinants of the disease can be assessed with ease. Combined with high-throughput characteristics, the employment of organ-on-chip technology would allow pharmaceutical companies and clinicians to test new therapeutic compounds and therapies. This will permit the screening of a large battery of new drugs in a fast and economic manner, to accelerate the diagnosis of the disease in the near future, and to test personalized treatments using cells from patients. In this review, we describe the latest advances in the field of organ-on-chip models of cancer metastasis and their integration with advanced imaging, screening and biosensing technologies for future precision medicine applications. We focus on their clinical applicability and market opportunities to drive us forward to the next generation of tumor models for improved cancer patient theranostics. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Identification of species with DNA-based technology: current progress and challenges.

    PubMed

    Pereira, Filipe; Carneiro, João; Amorim, António

    2008-01-01

    One of the grand challenges of modern biology is to develop accurate and reliable technologies for a rapid screening of DNA sequence variation. This topic of research is of prime importance for the detection and identification of species in numerous fields of investigation, such as taxonomy, epidemiology, forensics, archaeology or ecology. Molecular identification is also central for the diagnosis, treatment and control of infections caused by different pathogens. In recent years, a variety of DNA-based approaches have been developed for the identification of individuals in a myriad of taxonomic groups. Here, we provide an overview of most commonly used assays, with emphasis on those based on DNA hybridizations, restriction enzymes, random PCR amplifications, species-specific PCR primers and DNA sequencing. A critical evaluation of all methods is presented focusing on their discriminatory power, reproducibility and user-friendliness. Having in mind that the current trend is to develop small-scale devices with a high-throughput capacity, we briefly review recent technological achievements for DNA analysis that offer great potentials for the identification of species.

  13. Advances in microfluidics for drug discovery.

    PubMed

    Lombardi, Dario; Dittrich, Petra S

    2010-11-01

    Microfluidics is considered as an enabling technology for the development of unconventional and innovative methods in the drug discovery process. The concept of micrometer-sized reaction systems in the form of continuous flow reactors, microdroplets or microchambers is intriguing, and the versatility of the technology perfectly fits with the requirements of drug synthesis, drug screening and drug testing. In this review article, we introduce key microfluidic approaches to the drug discovery process, highlighting the latest and promising achievements in this field, mainly from the years 2007 - 2010. Despite high expectations of microfluidic approaches to several stages of the drug discovery process, up to now microfluidic technology has not been able to significantly replace conventional drug discovery platforms. Our aim is to identify bottlenecks that have impeded the transfer of microfluidics into routine platforms for drug discovery and show some recent solutions to overcome these hurdles. Although most microfluidic approaches are still applied only for proof-of-concept studies, thanks to creative microfluidic research in the past years unprecedented novel capabilities of microdevices could be demonstrated, and general applicable, robust and reliable microfluidic platforms seem to be within reach.

  14. Comparison of Adsorbed Mercury Screening Method With Cold-Vapor Atomic Absorption Spectrophotometry for Determination of Mercury in Soil

    NASA Technical Reports Server (NTRS)

    Easterling, Donald F.; Hovanitz, Edward S.; Street, Kenneth W.

    2000-01-01

    A field screening method for the determination of elemental mercury in environmental soil samples involves the thermal desorption of the mercury from the sample onto gold and then the thermal desorption from the gold to a gold-film mercury vapor analyzer. This field screening method contains a large number of conditions that could be optimized for the various types of soils encountered. In this study, the conditions were optimized for the determination of mercury in silty clay materials, and the results were comparable to the cold-vapor atomic absorption spectrophotometric method of determination. This paper discusses the benefits and disadvantages of employing the field screening method and provides the sequence of conditions that must be optimized to employ this method of determination on other soil types.

  15. Concise review: modeling central nervous system diseases using induced pluripotent stem cells.

    PubMed

    Zeng, Xianmin; Hunsberger, Joshua G; Simeonov, Anton; Malik, Nasir; Pei, Ying; Rao, Mahendra

    2014-12-01

    Induced pluripotent stem cells (iPSCs) offer an opportunity to delve into the mechanisms underlying development while also affording the potential to take advantage of a number of naturally occurring mutations that contribute to either disease susceptibility or resistance. Just as with any new field, several models of screening are being explored, and innovators are working on the most efficient methods to overcome the inherent limitations of primary cell screens using iPSCs. In the present review, we provide a background regarding why iPSCs represent a paradigm shift for central nervous system (CNS) disease modeling. We describe the efforts in the field to develop more biologically relevant CNS disease models, which should provide screening assays useful for the pharmaceutical industry. We also provide some examples of successful uses for iPSC-based screens and suggest that additional development could revolutionize the field of drug discovery. The development and implementation of these advanced iPSC-based screens will create a more efficient disease-specific process underpinned by the biological mechanism in a patient- and disease-specific manner rather than by trial-and-error. Moreover, with careful and strategic planning, shared resources can be developed that will enable exponential advances in the field. This will undoubtedly lead to more sensitive and accurate screens for early diagnosis and allow the identification of patient-specific therapies, thus, paving the way to personalized medicine. ©AlphaMed Press.

  16. Consumer preferences for teledermoscopy screening to detect melanoma early.

    PubMed

    Spinks, Jean; Janda, Monika; Soyer, H Peter; Whitty, Jennifer A

    2016-01-01

    'Store and forward' teledermoscopy is a technology with potential advantages for melanoma screening. Any large-scale implementation of this technology is dependent on consumer acceptance. To investigate preferences for melanoma screening options compared with skin self-examination in adults considered to be at increased risk of developing skin cancer. A discrete choice experiment was completed by 35 consumers, all of whom had prior experience with the use of teledermoscopy, in Queensland, Australia. Participants made 12 choices between screening alternatives described by seven attributes including monetary cost. A mixed logit model was used to estimate the relative weights that consumers place on different aspects of screening, along with the marginal willingness to pay for teledermoscopy as opposed to screening at a clinic. Overall, participants preferred screening/diagnosis by a health professional rather than skin self-examination. Key drivers of screening choice were for results to be reviewed by a dermatologist; a higher detection rate; fewer non-cancerous moles being removed in relation to every skin cancer detected; and less time spent away from usual activities. On average, participants were willing to pay AUD110 to have teledermoscopy with dermatologist review available to them as a screening option. Consumers preferentially value aspects of care that are more feasible with a teledermoscopy screening model, as compared with other skin cancer screening and diagnosis options. This study adds to previous literature in the area which has relied on the use of consumer satisfaction scales to assess the acceptability of teledermoscopy. © The Author(s) 2015.

  17. Prediction of success in FAA air traffic control field training as a function of selection and screening test performance.

    DOT National Transportation Integrated Search

    1989-05-01

    This study compared correlations between Office of Personnel Management (OPM) selection test scores for Air Traffic Control Specialists (ATCSs) and scores from the FAA Academy's second-stage screening program with measures of field training performan...

  18. TMIST Breast Screening Study

    Cancer.gov

    TMIST is a randomized breast screening trial that compares two Food and Drug Administration (FDA)-approved types of digital mammography, standard digital mammography (2-D) with a newer technology called tomosynthesis mammography (3-D).

  19. New technologies in cervical cancer precursor detection.

    PubMed

    Soler, M E; Blumenthal, P D

    2000-09-01

    The current literature reflects three routes toward improving cervical cancer screening. The first is to improve the test qualities of cytology-based screening. The use of liquid-based cytology and computerized analysis of Papanicolaou tests are examples of attempts at this approach. Secondly, through various combinations of parallel or sequential tests, either the sensitivity or the specificity of a given test could be improved depending on the tests chosen and the order in which they were performed (eg, Papanicolaou test followed by human papillomavirus [HPV] or vice versa). Several excellent studies have been published this year on the use of HPV DNA testing as a primary screening modality and as an adjunct to the triage of mildly abnormal cytologic findings. The recent literature also reflects increasing interest in visual inspection of the cervix and self-collected samples for HPV testing as an equally effective and viable alternative to cytology in low-resource settings. A third possibility is to make use of advances in digital and spectroscopic techniques. In these cost-conscious times, a significant number of articles address the cost-effectiveness of these technologies and the real value of cervical cancer screening. This article reviews the current literature concerning both the advent of new cervical cancer screening technologies and the rediscovery of old ones.

  20. Probing dark energy with atom interferometry

    NASA Astrophysics Data System (ADS)

    Burrage, Clare; Copeland, Edmund J.; Hinds, E. A.

    2015-03-01

    Theories of dark energy require a screening mechanism to explain why the associated scalar fields do not mediate observable long range fifth forces. The archetype of this is the chameleon field. Here we show that individual atoms are too small to screen the chameleon field inside a large high-vacuum chamber, and therefore can detect the field with high sensitivity. We derive new limits on the chameleon parameters from existing experiments, and show that most of the remaining chameleon parameter space is readily accessible using atom interferometry.

  1. iPSC-based drug screening for Huntington's disease.

    PubMed

    Zhang, Ningzhe; Bailus, Barbara J; Ring, Karen L; Ellerby, Lisa M

    2016-05-01

    Huntington's disease (HD) is an autosomal dominant neurodegenerative disorder, caused by an expansion of the CAG repeat in exon 1 of the huntingtin gene. The disease generally manifests in middle age with both physical and mental symptoms. There are no effective treatments or cures and death usually occurs 10-20 years after initial symptoms. Since the original identification of the Huntington disease associated gene, in 1993, a variety of models have been created and used to advance our understanding of HD. The most recent advances have utilized stem cell models derived from HD-patient induced pluripotent stem cells (iPSCs) offering a variety of screening and model options that were not previously available. The discovery and advancement of technology to make human iPSCs has allowed for a more thorough characterization of human HD on a cellular and developmental level. The interaction between the genome editing and the stem cell fields promises to further expand the variety of HD cellular models available for researchers. In this review, we will discuss the history of Huntington's disease models, common screening assays, currently available models and future directions for modeling HD using iPSCs-derived from HD patients. This article is part of a Special Issue entitled SI: PSC and the brain. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. A high-throughput liquid bead array-based screening technology for Bt presence in GMO manipulation.

    PubMed

    Fu, Wei; Wang, Huiyu; Wang, Chenguang; Mei, Lin; Lin, Xiangmei; Han, Xueqing; Zhu, Shuifang

    2016-03-15

    The number of species and planting areas of genetically modified organisms (GMOs) has been rapidly developed during the past ten years. For the purpose of GMO inspection, quarantine and manipulation, we have now devised a high-throughput Bt-based GMOs screening method based on the liquid bead array. This novel method is based on the direct competitive recognition between biotinylated antibodies and beads-coupled antigens, searching for Bt presence in samples if it contains Bt Cry1 Aa, Bt Cry1 Ab, Bt Cry1 Ac, Bt Cry1 Ah, Bt Cry1 B, Bt Cry1 C, Bt Cry1 F, Bt Cry2 A, Bt Cry3 or Bt Cry9 C. Our method has a wide GMO species coverage so that more than 90% of the whole commercialized GMO species can be identified throughout the world. Under our optimization, specificity, sensitivity, repeatability and availability validation, the method shows a high specificity and 10-50 ng/mL sensitivity of quantification. We then assessed more than 1800 samples in the field and food market to prove capacity of our method in performing a high throughput screening work for GMO manipulation. Our method offers an applicant platform for further inspection and research on GMO plants. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Disease modeling using human induced pluripotent stem cells: lessons from the liver.

    PubMed

    Gieseck, Richard L; Colquhoun, Jennifer; Hannan, Nicholas R F

    2015-01-01

    Human pluripotent stem cells (hPSCs) have the capacity to differentiate into any of the hundreds of distinct cell types that comprise the human body. This unique characteristic has resulted in considerable interest in the field of regenerative medicine, given the potential for these cells to be used to protect, repair, or replace diseased, injured, and aged cells within the human body. In addition to their potential in therapeutics, hPSCs can be used to study the earliest stages of human development and to provide a platform for both drug screening and disease modeling using human cells. Recently, the description of human induced pluripotent stem cells (hIPSCs) has allowed the field of disease modeling to become far more accessible and physiologically relevant, as pluripotent cells can be generated from patients of any genetic background. Disease models derived from hIPSCs that manifest cellular disease phenotypes have been established to study several monogenic diseases; furthermore, hIPSCs can be used for phenotype-based drug screens to investigate complex diseases for which the underlying genetic mechanism is unknown. As a result, the use of stem cells as research tools has seen an unprecedented growth within the last decade as researchers look for in vitro disease models which closely mimic in vivo responses in humans. Here, we discuss the beginnings of hPSCs, starting with isolation of human embryonic stem cells, moving into the development and optimization of hIPSC technology, and ending with the application of hIPSCs towards disease modeling and drug screening applications, with specific examples highlighting the modeling of inherited metabolic disorders of the liver. This article is part of a Special Issue entitled Linking transcription to physiology in lipodomics. Crown Copyright © 2014. Published by Elsevier B.V. All rights reserved.

  4. Global landscape assessment of screening technologies for medicine quality assurance: stakeholder perceptions and practices from ten countries.

    PubMed

    Roth, Lukas; Nalim, Ameena; Turesson, Beth; Krech, Laura

    2018-04-25

    The spread of substandard and falsified (SF) medical products constitutes a growing global public health concern. Some countries use portable, handheld screening technologies (STs) in the field to accelerate detection of SF medicines and reduce the number of medicine samples that undergo costly and time-consuming confirmatory analysis. A multi-country, multi-stakeholder landscape assessment utilizing qualitative methodology was used to examine practices and perceptions related to the use of STs. Qualitative interview guides were designed using the results of a literature review and comprised of open-ended questions with the study participants, who were from national medicine regulatory authorities, pharmaceutical manufacturers, pharmacies, and distributors. Ten geographically and economically diverse countries were selected: Argentina, China, Egypt, India, Jordan, Mexico, Nigeria, Philippines, the United States, and Zimbabwe. Of the completed 53 interviews, 32 were in-person, 16 were phone interviews, and 5 were via written questionnaires. Data analysis shows a wide variation in understanding and usage of STs in different sectors. Virtually all of the study participants indicated a lack of objective, accessible information on STs to advise them on what technologies would be beneficial for their needs. Study participants also described their ideal capabilities of the next generation of STs, including shareable spectral libraries, lower acquisition costs, lesser training requirements, and in-country maintenance and technical support. The results and recommendations presented in this article can be used to help regulators communicate and justify their needs to acquire and invest in new STs. There is a need for additional standardized, trustworthy and scientifically sound evaluations of STs, and to support regulators to effectively deploy the most promising technologies. ST manufacturers can take into account some of the limitations of the technologies the interviewees identified in this article, such as a dearth of technologies, which provide quantitative information about the active ingredient, and take steps to address them to better serve their customers. These results and recommendations, can catalyze research and actionable interventions into the development, review, application, and use of STs.

  5. Universal Newborn Screening and Adverse Medical Outcomes: A Historical Note

    ERIC Educational Resources Information Center

    Brosco, Jeffrey P.; Seider, Michael I.; Dunn, Angela C.

    2006-01-01

    Universal newborn screening programs for metabolic disorders are typically described as a triumph of medicine and public policy in the US over the last 50 years. Advances in science and technology, including the Human Genome Project, offer the opportunity to expand universal newborn screening programs to include many additional metabolic and…

  6. The New Screen Time: Computers, Tablets, and Smartphones Enter the Equation

    ERIC Educational Resources Information Center

    Wiles, Bradford B.; Schachtner, Laura; Pentz, Julie L.

    2016-01-01

    Emerging technologies attract children and push parents' and caregivers' abilities to attend to their families. This article presents recommendations related to the new version of screen time, which includes time with computers, tablets, and smartphones. Recommendations are provided for screen time for very young children and those in middle and…

  7. QR Codes in Higher Ed: Fad or Functional Tool?

    ERIC Educational Resources Information Center

    Gradel, Kathleen; Edson, Alden J.

    2013-01-01

    As higher education grapples with addressing the 21st century needs of learners, technology is a pervasive concern. Waters (2012) painted a picture of three historical "screens," namely the television screen, the computer monitor, and today's mobile device screen. As mobile devices become increasingly commonplace in the workplace and on the…

  8. Learning Effectiveness and Cognitive Loads in Instructional Materials of Programming Language on Single and Dual Screens

    ERIC Educational Resources Information Center

    Hsu, Jenq-Muh; Chang, Ting-Wen; Yu, Pao-Ta

    2012-01-01

    The teaching and learning environment in a traditional classroom typically includes a projection screen, a projector, and a computer within a digital interactive table. Instructors may apply multimedia learning materials using various information communication technologies to increase interaction effects. However, a single screen only displays a…

  9. Current Technologies and Recent Developments for Screening of HPV-Associated Cervical and Oropharyngeal Cancers

    PubMed Central

    Shah, Sunny S.; Senapati, Satyajyoti; Klacsmann, Flora; Miller, Daniel L.; Johnson, Jeff J.; Chang, Hsueh-Chia; Stack, M. Sharon

    2016-01-01

    Mucosal infection by the human papillomavirus (HPV) is responsible for a growing number of malignancies, predominantly represented by cervical cancer and oropharyngeal squamous cell carcinoma. Because of the prevalence of the virus, persistence of infection, and long latency period, novel and low-cost methods are needed for effective population level screening and monitoring. We review established methods for screening of cervical and oral cancer as well as commercially-available techniques for detection of HPV DNA. We then describe the ongoing development of microfluidic nucleic acid-based biosensors to evaluate circulating host microRNAs that are produced in response to an oncogenic HPV infection. The goal is to develop an ideal screening platform that is low-cost, portable, and easy to use, with appropriate signal stability, sensitivity and specificity. Advances in technologies for sample lysis, pre-treatment and concentration, and multiplexed nucleic acid detection are provided. Continued development of these devices provides opportunities for cancer screening in low resource settings, for point-of-care diagnostics and self-screening, and for monitoring response to vaccination or surgical treatment. PMID:27618102

  10. Facile screening of potential xenoestrogens by an estrogen receptor-based reusable optical biosensor.

    PubMed

    Liu, Lanhua; Zhou, Xiaohong; Lu, Yun; Shan, Didi; Xu, Bi; He, Miao; Shi, Hanchang; Qian, Yi

    2017-11-15

    The apparent increase in hormone-induced cancers and disorders of the reproductive tract has led to a growing demand for new technologies capable of screening xenoestrogens. We reported an estrogen receptor (ER)-based reusable fiber biosensor for facile screening estrogenic compounds in environment. The bioassay is based on the competition of xenoestrogens with 17β-estradiol (E 2 ) for binding to the recombinant receptor of human estrogen receptor α (hERα) protein, leaving E 2 free to bind to fluorophore-labeled anti-E 2 monoclonal antibody. Unbound anti-E 2 antibody then binds to the immobilized E 2 -protein conjugate on the fiber surface, and is detected by fluorescence emission induced by evanescent field. As expected, the stronger estrogenic activity of xenoestrogen would result in the weaker fluorescent signal. Three estrogen-agonist compounds, diethylstilbestrol (DES), 4-n-nonylphenol (NP) and 4-n-octylphenol (OP), were chosen as a paradigm for validation of this assay. The rank order of estrogenic potency determined by this biosensor was DES>OP>NP, which were consistent with the published results in numerous studies. Moreover, the E 2 -protein conjugate modified optical fiber was robust enough for over 300 sensing cycles with the signal recoveries ranging from 90% to 100%. In conclusion, the biosensor is reusable, reliable, portable and amenable to on-line operation, providing a facile, efficient and economical alternative to screen potential xenoestrogens in environment. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. [Study on baking processing technology of hui medicine Aconitum flavum].

    PubMed

    Fu, Xue-yan; Zhang, Bai-tong; Li, Ting-ting; Dong, Lin; Hao, Wen-jing; Yu, Liang

    2013-12-01

    To screen and optimize the processing technology of Aconitum flavum. The acute-toxicity, anti-inflammatory and analgesic experiments were used as indexes. Four processing methods, including decoction, streaming, baking and processing with Chebulae Fructus decoction, were compared to screen the optimum processing method for Aconitum flavum. The baking time was also optimized. The optimal baked technology was that 1-2 mm decoction pieces was baked at 105 degrees C for 3 hours. The baking method is proved to be the optimal processing method of Aconitum flavum. It is shown that this method is simple and stable.

  12. Designer drugs: the evolving science of drug discovery.

    PubMed

    Wanke, L A; DuBose, R F

    1998-07-01

    Drug discovery and design are fundamental to drug development. Until recently, most drugs were discovered through random screening or developed through molecular modification. New technologies are revolutionizing this phase of drug development. Rational drug design, using powerful computers and computational chemistry and employing X-ray crystallography, nuclear magnetic resonance spectroscopy, and three-dimensional quantitative structure activity relationship analysis, is creating highly specific, biologically active molecules by virtual reality modeling. Sophisticated screening technologies are eliminating all but the most active lead compounds. These new technologies promise more efficacious, safe, and cost-effective medications, while minimizing drug development time and maximizing profits.

  13. Constructive Activation of Reservoir-Resident Microbes for Enhanced Oil Recovery

    NASA Astrophysics Data System (ADS)

    DeBruyn, R. P.

    2017-12-01

    Microbial communities living in subsurface oil reservoirs biodegrade oil, producing methane. If this process could create methane within the waterflooded pore spaces of an oilfield, the methane would be expected to remain and occupy pore space, decreasing water relative permeability, diverting water flow, and increasing oil recovery by expanding the swept zone of the waterflood. This approach was tested in an oilfield in northern Montana. Preliminary assessments were made of geochemical conditions and microbiological habitations. Then, a formulation of microbial activators, with composition tailored for the reservoir's conditions, was metered at low rates into the existing injection water system for one year. In the field, the responses observed included improved oil production performance; a slight increase in injection pressure; and increased time needed for tracers to move between injection and producing wells. We interpret these results to confirm that successful stimulation of the microbial community caused more methane to be created within the swept zone of the waterflooded reservoir. When the methane exsolved as water flowed between high-pressure injection and low-pressure production wells, the bubbles occupied pore space, reducing water saturation and relative permeability, and re-directing some water flow to "slower" unswept rock with lower permeability and higher oil saturation. In total, the waterflood's swept zone had been expanded to include previously-unflooded rock. This technology was applied in this field after screening based on careful anaerobic sampling, advanced microbiological analysis, and the ongoing success of its waterflood. No reservoir or geological or geophysical simulation models were employed, and physical modifications to field facilities were minor. This technology of utilizing existing microbial populations for enhanced oil recovery can therefore be considered for deployment into waterfloods where small scale, advanced maturity, or insufficiency of data make other technologies too expensive.

  14. Digital mapping in extreme and remote environments

    NASA Astrophysics Data System (ADS)

    Andersson, Joel; Bauer, Tobias; Sarlus, Zimer; Zainy, Maher; Brethes, Anais

    2017-04-01

    During the last few years, Luleå University of Technology has performed a series of research projects in remote areas with extreme climatic conditions using digital mapping technologies. The majority of past and ongoing research projects focus on the arctic regions of the Fennoscandian Shield and Greenland but also on the Zagros fold-and-thrust belt in northern Iraq. Currently, we use the Midland Valley application FieldMove on iPad mini devices with ruggedized casings. As all projects have a strong focus on geological field work, harsh climatic conditions are a challenge not only for the geologists but also for the digital mapping hardware. In the arctic regions especially cold temperatures affect battery lifetime and performance of the screens. But also high temperatures are restricting digital mapping. From experience, a typical temperature range where digital mapping, using iPad tablets, is possible lies between -20 and +40 degrees. Furthermore, the remote character of field areas complicates access but also availability of electricity. By a combination of robust solar chargers and ruggedized batteries we are able to work entirely autarkical. Additionally, we are currently installing a drone system that allows us to map outcrops normally inaccessible because of safety reasons or time deficiency. The produced data will subsequently be taken into our Virtual Reality studio for interpretation and processing. There we will be able to work also with high resolution DEM data from Lidar scanning allowing us to interpret structural features such as post-glacial faults in areas that are otherwise only accessible by helicopter. By combining digital field mapping with drone technique and a Virtual Reality studio we are able to work in hardly accessible areas, improve safety during field work and increase efficiency substantially.

  15. Influence of magnetic fields on the color screening masses

    NASA Astrophysics Data System (ADS)

    Bonati, Claudio; D'Elia, Massimo; Mesiti, Michele; Negro, Francesco; Rucci, Andrea; Sanfilippo, Francesco

    2018-03-01

    We present some recent results obtained in the study of the color magnetic and electric screening masses in the QCD plasma. In particular, we discuss how the masses get modified by strong external fields which are expected to be created in physical situations such as heavy-ion collisions.

  16. Atrial fibrillation screening in pharmacies using an iPhone ECG: a qualitative review of implementation.

    PubMed

    Lowres, Nicole; Krass, Ines; Neubeck, Lis; Redfern, Julie; McLachlan, Andrew J; Bennett, Alexandra A; Freedman, S Ben

    2015-12-01

    Atrial fibrillation guidelines advocate screening to identify undiagnosed atrial fibrillation. Community pharmacies may provide an opportunistic venue for such screening. To explore the experience of implementing an atrial fibrillation screening service from the pharmacist's perspective including: the process of study implementation; the perceived benefits; the barriers and enablers; and the challenges for future sustainability of atrial fibrillation screening within pharmacies. Setting Interviews were conducted face-to-face in the pharmacy or via telephone, according to pharmacist preference. The 'SEARCH-AF study' screened 1000 pharmacy customers aged ≥65 years using an iPhone electrocardiogram, identifying 1.5 % with undiagnosed atrial fibrillation. Nine pharmacists took part in semi-structured interviews. Interviews were transcribed in full and thematically analysed. Qualitative analysis of the experience of implementing an AF screening service from the pharmacist's perspective. Four broad themes relating to service provision were identified: (1) interest and engagement in atrial fibrillation screening by pharmacists, customers, and doctors with the novel, easy-to-use electrocardiogram technology serving as an incentive to undergo screening and an education tool for pharmacists to use with customers; (2) perceived benefits to the pharmacist including increased job satisfaction, improvement in customer relations and pharmacy profile by fostering enhanced customer care and the educational role of pharmacists; (3) implementation barriers including managing workflow, and enablers such as personal approaches for recruitment, and allocating time to discuss screening process and fears; and, (4) potential for sustainable future implementation including remuneration linked to government or pharmacy incentives, combined cardiovascular screening, and automating sections of risk-assessments using touch-screen technology. Atrial fibrillation screening in pharmacies is well accepted by pharmacists and customers. Many pharmacists combined atrial fibrillation screening with other health screens reporting improved time-efficiency and greater customer satisfaction. Widespread implementation of atrial fibrillation screening requires longterm funding, which could be provided for a combined cardiovascular screening service. Further research could focus on feasibility and cost-effectiveness of combined cardiovascular screening in pharmacies.

  17. [Emphasis on promotion of the adaptive technology is the sky point of improving of treatment and prevention level of glaucoma].

    PubMed

    Wang, Ning-li

    2013-11-01

    Promoting the control of primary angle-closure glaucoma (PACG) and primary open angle glaucoma (POAG) is most important prevention program of blindness in China. PACG has been incorporated into the prevention program of blindness in China based on the population-based screening studies. However, the clinical screening should be strengthened in POAG. The creation of a series of appropriate technologies suitable for glaucoma prevention and management has been achieved in China, especially for PACG. The technologies have been evaluated in the pilot areas and obtained very good results in China. It is recommended to develop new technology suitable for glaucoma management using the following workflow: research, development, and evaluation by large scale hospitals, and then clinical trial in the pilot areas. After a cost-benefit analysis is made, the new technology can be promoted and applied in clinical practice nationwide. We propose to gradually formed a strategical mode of "screening in township hospitals, intervention in county hospitals, and technical support and tackling in provincial hospitals" in order to improve the level of prevention and treatment of glaucoma and reduce the blindness incidence rate caused by glaucoma.

  18. Expanded newborn screening: social and ethical issues.

    PubMed

    Dhondt, Jean-Louis

    2010-10-01

    Newborn screening and genetic testing have expanded rapidly in the last decade with the advent of multiplex (e.g., tandem mass spectrometry) and/or DNA technologies. However, screening panels include a large number of disorders, which may not meet all of the traditional screening criteria, established in late 1960s, and used for years to justify screening programs. After a period of expansion driven by technological advances, many reports have reconsidered the justification of expanded programs. Many factors have contributed to test-panel discrepancies between countries. The test-panel review methodology, the way health benefits are weighed against harms, and the socioeconomic-political environment all play a role. Expansion of screening also requires reconsideration of the infrastructure (ideally, in the context of national plans for rare diseases) to support testing, counselling, education, treatment, and follow-up. Consequently, economic aspects cannot be ignored and can be a limitation for expansion. New ethical questions have emerged: risks of discrimination or stigmatization, respect of the autonomy of persons to make decisions, parental anxiety resulting from a false positive test (especially when reporting to parents screening results for untreatable conditions identified as by-products of screening), etc. For disorders where there is not yet confirmation of benefit, it may be prudent to recommend pilot screening and to have a mechanism that can be used to adapt or even to stop a program.

  19. Technology-enabled examinations of cardiac rhythm, optic nerve, oral health, tympanic membrane, gait and coordination evaluated jointly with routine health screenings: an observational study at the 2015 Kumbh Mela in India

    PubMed Central

    Gupta, Otkrist; Patalano II, Vincent; Mohit, Mrinal; Merchant, Rikin; Subramanian, S V

    2018-01-01

    Objectives Technology-enabled non-invasive diagnostic screening (TES) using smartphones and other point-of-care medical devices was evaluated in conjunction with conventional routine health screenings for the primary care screening of patients. Design Dental conditions, cardiac ECG arrhythmias, tympanic membrane disorders, blood oxygenation levels, optic nerve disorders and neurological fitness were evaluated using FDA-approved advanced smartphone powered technologies. Routine health screenings were also conducted. A novel remote web platform was developed to allow expert physicians to examine TES data and compare efficacy with routine health screenings. Setting The study was conducted at a primary care centre during the 2015 Kumbh Mela in Maharashtra, India. Participants 494 consenting 18–90 years old adults attending the 2015 Kumbh Mela were tested. Results TES and routine health screenings identified unique clinical conditions in distinct patients. Intraoral fluorescent imaging classified 63.3% of the population with dental caries and periodontal diseases. An association between poor oral health and cardiovascular illnesses was also identified. Tympanic membrane imaging detected eardrum abnormalities in 13.0% of the population, several with a medical history of hearing difficulties. Gait and coordination issues were discovered in eight subjects and one subject had arrhythmia. Cross-correlations were observed between low oxygen saturation and low body mass index (BMI) with smokers (p=0.0087 and p=0.0122, respectively), and high BMI was associated with elevated blood pressure in middle-aged subjects. Conclusions TES synergistically identified clinically significant abnormalities in several subjects who otherwise presented as normal in routine health screenings. Physicians validated TES findings and used routine health screening data and medical history responses for comprehensive diagnoses for at-risk patients. TES identified high prevalence of oral diseases, hypertension, obesity and ophthalmic conditions among the middle-aged and elderly Indian population, calling for public health interventions. PMID:29678964

  20. Suitability Screening Test for Marine Corps Air Traffic Controllers Phase 2

    DTIC Science & Technology

    2013-06-10

    Karen M. Walker, Ph.D. William L. Farmer, Ph.D. Rebecca C. Roberts, MS Navy Personnel Research, Studies, and Technology NPRST-TR-13-2...June 2013 Suitability Screening Test for Marine Corps Air Traffic Controllers Phase II Karen M. Walker, Ph.D. William L. Farmer, Ph.D. Rebecca...C. Roberts, MS Navy Personnel Research, Studies, and Technology Reviewed by Tanja Blackstone , Ph.D. Approved and released by D. M. Cashbaugh

  1. Suitability Screening Test for Marine Corps Air Traffic Controllers. Phase 2

    DTIC Science & Technology

    2013-06-01

    Karen M. Walker, Ph.D. William L. Farmer, Ph.D. Rebecca C. Roberts, MS Navy Personnel Research, Studies, and Technology NPRST-TR-13-2...June 2013 Suitability Screening Test for Marine Corps Air Traffic Controllers Phase II Karen M. Walker, Ph.D. William L. Farmer, Ph.D. Rebecca...C. Roberts, MS Navy Personnel Research, Studies, and Technology Reviewed by Tanja Blackstone , Ph.D. Approved and released by D. M. Cashbaugh

  2. High-throughput strategies for the discovery and engineering of enzymes for biocatalysis.

    PubMed

    Jacques, Philippe; Béchet, Max; Bigan, Muriel; Caly, Delphine; Chataigné, Gabrielle; Coutte, François; Flahaut, Christophe; Heuson, Egon; Leclère, Valérie; Lecouturier, Didier; Phalip, Vincent; Ravallec, Rozenn; Dhulster, Pascal; Froidevaux, Rénato

    2017-02-01

    Innovations in novel enzyme discoveries impact upon a wide range of industries for which biocatalysis and biotransformations represent a great challenge, i.e., food industry, polymers and chemical industry. Key tools and technologies, such as bioinformatics tools to guide mutant library design, molecular biology tools to create mutants library, microfluidics/microplates, parallel miniscale bioreactors and mass spectrometry technologies to create high-throughput screening methods and experimental design tools for screening and optimization, allow to evolve the discovery, development and implementation of enzymes and whole cells in (bio)processes. These technological innovations are also accompanied by the development and implementation of clean and sustainable integrated processes to meet the growing needs of chemical, pharmaceutical, environmental and biorefinery industries. This review gives an overview of the benefits of high-throughput screening approach from the discovery and engineering of biocatalysts to cell culture for optimizing their production in integrated processes and their extraction/purification.

  3. Understanding the Knowledge Gap Experienced by U.S. Safety Net Patients in Teleretinal Screening.

    PubMed

    George, Sheba M; Hayes, Erin Moran; Fish, Allison; Daskivich, Lauren Patty; Ogunyemi, Omolola I

    2016-01-01

    Safety-net patients' socioeconomic barriers interact with limited digital and health literacies to produce a "knowledge gap" that impacts the delivery of healthcare via telehealth technologies. Six focus groups (2 African- American and 4 Latino) were conducted with patients who received teleretinal screening in a U.S. urban safety-net setting. Focus groups were analyzed using a modified grounded theory methodology. Findings indicate that patients' knowledge gap is primarily produced at three points during the delivery of care: (1) exacerbation of patients' pre-existing personal barriers in the clinical setting; (2) encounters with technology during screening; and (3) lack of follow up after the visit. This knowledge gap produces confusion, potentially limiting patients' perceptions of care and their ability to manage their own care. It may be ameliorated through delivery of patient education focused on both disease pathology and specific role of telehealth technologies in disease management.

  4. Wireless power transfer magnetic couplers

    DOEpatents

    Wu, Hunter; Gilchrist, Aaron; Sealy, Kylee

    2016-01-19

    A magnetic coupler is disclosed for wireless power transfer systems. A ferrimagnetic component is capable of guiding a magnetic field. A wire coil is wrapped around at least a portion of the ferrimagnetic component. A screen is capable of blocking leakage magnetic fields. The screen may be positioned to cover at least one side of the ferrimagnetic component and the coil. A distance across the screen may be at least six times an air gap distance between the ferrimagnetic component and a receiving magnetic coupler.

  5. Multiloop atom interferometer measurements of chameleon dark energy in microgravity

    NASA Astrophysics Data System (ADS)

    Chiow, Sheng-wey; Yu, Nan

    2018-02-01

    Chameleon field is one of the promising candidates of dark energy scalar fields. As in all viable candidate field theories, a screening mechanism is implemented to be consistent with all existing tests of general relativity. The screening effect in the chameleon theory manifests its influence limited only to the thin outer layer of a bulk object, thus producing extra forces orders of magnitude weaker than that of the gravitational force of the bulk. For pointlike particles such as atoms, the depth of screening is larger than the size of the particle, such that the screening mechanism is ineffective and the chameleon force is fully expressed on the atomic test particles. Extra force measurements using atom interferometry are thus much more sensitive than bulk mass based measurements, and indeed have placed the most stringent constraints on the parameters characterizing chameleon field. In this paper, we present a conceptual measurement approach for chameleon force detection using atom interferometry in microgravity, in which multiloop atom interferometers exploit specially designed periodic modulation of chameleon fields. We show that major systematics of the dark energy force measurements, i.e., effects of gravitational forces and their gradients, can be suppressed below all hypothetical chameleon signals in the parameter space of interest.

  6. Young Men’s Views Toward the Barriers and Facilitators of Internet-Based Chlamydia Trachomatis Screening: Qualitative Study

    PubMed Central

    McDaid, Lisa

    2013-01-01

    Background There is a growing number of Internet-based approaches that offer young people screening for sexually transmitted infections. Objective This paper explores young men’s views towards the barriers and facilitators of implementing an Internet-based screening approach. The study sought to consider ways in which the proposed intervention would reach and engage men across ages and socioeconomic backgrounds. Methods This qualitative study included 15 focus groups with 60 heterosexual young men (aged 16-24 years) across central Scotland, drawn across age and socioeconomic backgrounds. Focus groups began by obtaining postcode data to allocate participants to a high/low deprivation category. Focus group discussions involved exploration of men’s knowledge of chlamydia, use of technology, and views toward Internet-based screening. Men were shown sample screening invitation letters, test kits, and existing screening websites to facilitate discussions. Transcripts from audio recordings were analyzed with "Framework Analysis". Results Men’s Internet and technology use was heterogeneous in terms of individual practices, with greater use among older men (aged 20-24 years) than teenagers and some deprivation-related differences in use. We detail three themes related to barriers to successful implementation: acceptability, confidentiality and privacy concerns, and language, style, and content. These themes identify ways Internet-based screening approaches may fail to engage some men, such as by raising anxiety and failing to convey confidentiality. Men wanted screening websites to frame screening as a serious issue, rather than using humorous images and text. Participants were encouraged to reach a consensus within their groups on their broad design and style preferences for a screening website; this led to a set of common preferences that they believed were likely to engage men across age and deprivation groups and lead to greater screening uptake. Conclusions The Internet provides opportunities for re-evaluating how we deliver sexual health promotion and engage young men in screening. Interventions using such technology should focus on uptake by age and socioeconomic background. Young people should be engaged as coproducers of intervention materials and websites to ensure messages and content are framed appropriately within a fast-changing environment. Doing so may go some way to addressing the overall lower levels of testing and screening among men compared with women. PMID:24300158

  7. Young men's views toward the barriers and facilitators of Internet-based Chlamydia trachomatis screening: qualitative study.

    PubMed

    Lorimer, Karen; McDaid, Lisa

    2013-12-03

    There is a growing number of Internet-based approaches that offer young people screening for sexually transmitted infections. This paper explores young men's views towards the barriers and facilitators of implementing an Internet-based screening approach. The study sought to consider ways in which the proposed intervention would reach and engage men across ages and socioeconomic backgrounds. This qualitative study included 15 focus groups with 60 heterosexual young men (aged 16-24 years) across central Scotland, drawn across age and socioeconomic backgrounds. Focus groups began by obtaining postcode data to allocate participants to a high/low deprivation category. Focus group discussions involved exploration of men's knowledge of chlamydia, use of technology, and views toward Internet-based screening. Men were shown sample screening invitation letters, test kits, and existing screening websites to facilitate discussions. Transcripts from audio recordings were analyzed with "Framework Analysis". Men's Internet and technology use was heterogeneous in terms of individual practices, with greater use among older men (aged 20-24 years) than teenagers and some deprivation-related differences in use. We detail three themes related to barriers to successful implementation: acceptability, confidentiality and privacy concerns, and language, style, and content. These themes identify ways Internet-based screening approaches may fail to engage some men, such as by raising anxiety and failing to convey confidentiality. Men wanted screening websites to frame screening as a serious issue, rather than using humorous images and text. Participants were encouraged to reach a consensus within their groups on their broad design and style preferences for a screening website; this led to a set of common preferences that they believed were likely to engage men across age and deprivation groups and lead to greater screening uptake. The Internet provides opportunities for re-evaluating how we deliver sexual health promotion and engage young men in screening. Interventions using such technology should focus on uptake by age and socioeconomic background. Young people should be engaged as coproducers of intervention materials and websites to ensure messages and content are framed appropriately within a fast-changing environment. Doing so may go some way to addressing the overall lower levels of testing and screening among men compared with women.

  8. Children’s Environmental Health in the Digital Era: Understanding Early Screen Exposure as a Preventable Risk Factor for Obesity and Sleep Disorders

    PubMed Central

    Wolf, Candice; Wolf, Seth; Weiss, Miriam; Nino, Gustavo

    2018-01-01

    The quantity, accessibility and focus on child-targeted programming has exponentially increased since it entered American households in the early 1900s. It may have started with the television (TV), but technology has evolved and now fits in our pockets; as of 2017, 95% of American families own a smartphone. Availability and child-tailored content has subsequently led to a decrease in the age at initial screen exposure. The negative effects that accompany the current culture of early screen exposure are extensive and need to be considered as technology continues to enter the home and inundate social interactions. Increased levels of early screen exposure have been associated with decreased cognitive abilities, decreased growth, addictive behavior, poor school performance, poor sleep patterns, and increased levels of obesity. Research on the adverse effects of early screen exposure is mounting, but further epidemiological studies are still needed to inform prevention and regulation policies. PMID:29473855

  9. Children's Environmental Health in the Digital Era: Understanding Early Screen Exposure as a Preventable Risk Factor for Obesity and Sleep Disorders.

    PubMed

    Wolf, Candice; Wolf, Seth; Weiss, Miriam; Nino, Gustavo

    2018-02-23

    The quantity, accessibility and focus on child-targeted programming has exponentially increased since it entered American households in the early 1900s. It may have started with the television (TV), but technology has evolved and now fits in our pockets; as of 2017, 95% of American families own a smartphone. Availability and child-tailored content has subsequently led to a decrease in the age at initial screen exposure. The negative effects that accompany the current culture of early screen exposure are extensive and need to be considered as technology continues to enter the home and inundate social interactions. Increased levels of early screen exposure have been associated with decreased cognitive abilities, decreased growth, addictive behavior, poor school performance, poor sleep patterns, and increased levels of obesity. Research on the adverse effects of early screen exposure is mounting, but further epidemiological studies are still needed to inform prevention and regulation policies.

  10. Digital mammography: more microcalcifications, more columnar cell lesions without atypia.

    PubMed

    Verschuur-Maes, Anoek H J; van Gils, Carla H; van den Bosch, Maurice A A J; De Bruin, Peter C; van Diest, Paul J

    2011-09-01

    The incidence of columnar cell lesions in breast core needle biopsies since full-field digital mammography in comparison with screen-filmed mammography was analyzed. As tiny microcalcifications characterize columnar cell lesions at mammography, we hypothesized that more columnar cell lesions are diagnosed since full-field digital mammography due to its higher sensitivity for microcalcifications. In all, 3437 breast core needle biopsies performed in three hospitals and resulting from in total 55 159 mammographies were revised: 1424 taken in the screen-filmed mammography and 2013 in the full-field digital mammography period. Between the screen-filmed mammography and full-field digital mammography periods, we compared the proportion of mammographies that led to core needle biopsies, the mammographic indication for core needle biopsies (density, microcalcifications, or both) and the proportion of columnar cell lesions with or without atypia. The columnar cell lesions were graded according to Schnitt, and we included atypical ductal hyperplasia arising in the context of columnar cell lesions. Proportions were compared using χ(2) tests and prevalence ratios were adjusted for age and hospital. We found that more core needle biopsies per mammogram were taken in the full-field digital mammography period (7.6%) compared with the screen-filmed mammography period (5.0%, P<0.0001). Microcalcifications were more often diagnosed with full-field digital mammography than with screen-filmed mammography (adjusted prevalence ratio: 1.14, confidence interval 95%: 1.01-1.28). Core needle biopsies from the full-field digital mammography era showed more columnar cell lesions (10.8%) than those from the screen-filmed mammography era (4.9%; adjusted prevalence ratio: 1.93, confidence interval 95%: 1.48-2.51), particularly due to more columnar cell lesions without atypia (8.2% respectively 2.8%) while the proportion of columnar cell lesions with atypia remained nearly constant (2.0 vs 2.6%). In conclusion, since the implementation of full-field digital mammography, more microcalcifications are seen at mammography, more often resulting in core needle biopsies, which especially yields more columnar cell lesions without atypia.

  11. Novel data visualizations of X-ray data for aviation security applications using the Open Threat Assessment Platform (OTAP)

    NASA Astrophysics Data System (ADS)

    Gittinger, Jaxon M.; Jimenez, Edward S.; Holswade, Erica A.; Nunna, Rahul S.

    2017-02-01

    This work will demonstrate the implementation of a traditional and non-traditional visualization of x-ray images for aviation security applications that will be feasible with open system architecture initiatives such as the Open Threat Assessment Platform (OTAP). Anomalies of interest to aviation security are fluid, where characteristic signals of anomalies of interest can evolve rapidly. OTAP is a limited scope open architecture baggage screening prototype that intends to allow 3rd-party vendors to develop and easily implement, integrate, and deploy detection algorithms and specialized hardware on a field deployable screening technology [13]. In this study, stereoscopic images were created using an unmodified, field-deployed system and rendered on the Oculus Rift, a commercial virtual reality video gaming headset. The example described in this work is not dependent on the Oculus Rift, and is possible using any comparable hardware configuration capable of rendering stereoscopic images. The depth information provided from viewing the images will aid in the detection of characteristic signals from anomalies of interest. If successful, OTAP has the potential to allow for aviation security to become more fluid in its adaptation to the evolution of anomalies of interest. This work demonstrates one example that is easily implemented using the OTAP platform, that could lead to the future generation of ATR algorithms and data visualization approaches.

  12. Print news coverage of cancer: what prevention messages are conveyed when screening is newsworthy?

    PubMed

    Smith, Katherine Clegg; Kromm, Elizabeth Edsall; Klassen, Ann Carroll

    2010-08-01

    Americans are generally favorable towards cancer screening, but fatalistic about cancer prevention. News coverage shapes perceptions of cancer control in meaningful ways, but there is little consensus as to the impact of news on our understanding of and engagement in cancer screening practices. Our analysis of cancer screening-related print news coverage during a four month period in 2005 suggests that the newsworthiness of new screening technologies may undermine public confidence in currently available and effective secondary prevention programs, while promoting tests whose effectiveness is debated or not yet established. We conducted a structured text analysis of 517 cancer-related news articles from 15 leading daily newspapers and a subsequent qualitative analysis of the 79 screening news articles. Screening articles were analyzed for content related to criteria for screening effectiveness. Content patterns for each type of screening and cancer were also noted. News coverage consistently conveyed screening as important and highlighted the need to protect and expand access to screening. At the same time, to the extent that story content was framed by the newsworthiness of new tests and technologies this often indirectly called into question effective and established protocols and programs without providing any actionable alternative. This analysis revealed unexpected messages about screening that are potentially problematic for cancer control. The cancer control community should continue efforts to understand and shape news coverage of screening in order to promote balanced and action-oriented content. Research has shown that Americans hold conflicting views regarding cancer-having a favorable opinion of screening while simultaneously feeling fatalistic about prevention. Our analysis of print news stories on cancer screening suggests that the determination of screening's "newsworthiness" is related to newly developed tests and protocols, which may create demand for new tests whose effectiveness is unknown and undermine confidence in established and effective screening programs.

  13. Leveraging the Habit-Forming Aspects of Technology to Increase Levels of Physical Activity

    ERIC Educational Resources Information Center

    Rotich, Willy Kipkemboi

    2016-01-01

    The use of technology to promote physical activity has been rapidly gaining popularity as technological advances find ever-broadening applications. Though some technology aspects (i.e., on-screen video games) were for long perceived to be incompatible with efforts to diminish physical inactivity, evolving technology has made incorporating newer…

  14. [Induced pluripotent stem cells: a new paradigm to study human tissues].

    PubMed

    Sansac, Caroline; Assou, Said; Bouckenheimer, Julien; Lemaître, Jean-Marc; De Vos, John

    2016-01-01

    Induced pluripotent stem cells (iPSCs) are obtained by reprogramming differentiated cells through forced expression of four embryonic transcription factors. The discovery of this technology, able to transform a differentiated cell into a pluripotent cell, has profoundly shifted the paradigm of the concept of cell identity, since it is now possible to obtain in vitro any cell type from an initial sample of skin or blood cells from a healthy volunteer or patient. Applications of iPSCs are exceedingly large, and comprise the in vitro modeling of normal or pathological tissues, including for massive drug screening. They also open new therapeutic avenues in the field of regenerative medicine. © Société de Biologie, 2016.

  15. Static Multiple-Pole Homopolar Generator With a Superconducting Screen,

    DTIC Science & Technology

    1983-11-03

    STANAR193-A OlCFILE GORY 00 FOREIGN TECHNOLOGY DIVISION STATIC MULTIPLE-POLE HOMOPOLAR GENERATOR WITH A SUPERC9ONDUCTING SCREEN by V.P. Kartsev, avld...November 1983 MICROFICHE MJR: FTD-83-C-001336 STATIC %fULTIPLE-POLE HOMOPOLAR GENERATOR WITH A SUPRCONDUCTING SCREEN By: V.P. Kartsev, and I.M. Yegorov...this translation were extracted from the best quality copy available. STATIC MULTIPLE-POLE HOMOPOLAR GENERATOR WITH A SUPERCONDUCTING SCREEN V.P

  16. Perceived Barriers and Facilitators of Using a Web-Based Interactive Decision Aid for Colorectal Cancer Screening in Community Practice Settings: Findings From Focus Groups With Primary Care Clinicians and Medical Office Staff

    PubMed Central

    2013-01-01

    Background Information is lacking about the capacity of those working in community practice settings to utilize health information technology for colorectal cancer screening. Objective To address this gap we asked those working in community practice settings to share their perspectives about how the implementation of a Web-based patient-led decision aid might affect patient-clinician conversations about colorectal cancer screening and the day-to-day clinical workflow. Methods Five focus groups in five community practice settings were conducted with 8 physicians, 1 physician assistant, and 18 clinic staff. Focus groups were organized using a semistructured discussion guide designed to identify factors that mediate and impede the use of a Web-based decision aid intended to clarify patient preferences for colorectal cancer screening and to trigger shared decision making during the clinical encounter. Results All physicians, the physician assistant, and 8 of the 18 clinic staff were active participants in the focus groups. Clinician and staff participants from each setting reported a belief that the Web-based patient-led decision aid could be an informative and educational tool; in all but one setting participants reported a readiness to recommend the tool to patients. The exception related to clinicians from one clinic who described a preference for patients having fewer screening choices, noting that a colonoscopy was the preferred screening modality for patients in their clinic. Perceived barriers to utilizing the Web-based decision aid included patients’ lack of Internet access or low computer literacy, and potential impediments to the clinics’ daily workflow. Expanding patients’ use of an online decision aid that is both easy to access and understand and that is utilized by patients outside of the office visit was described as a potentially efficient means for soliciting patients’ screening preferences. Participants described that a system to link the online decision aid to a computerized reminder system could promote a better understanding of patients’ screening preferences, though some expressed concern that such a system could be difficult to keep up and running. Conclusions Community practice clinicians and staff perceived the Web-based decision aid technology as promising but raised questions as to how the technology and resultant information would be integrated into their daily practice workflow. Additional research investigating how to best implement online decision aids should be conducted prior to the widespread adoption of such technology so as to maximize the benefits of the technology while minimizing workflow disruptions. PMID:24351420

  17. Effect-size measures as descriptors of assay quality in high-content screening: A brief review of some available methodologies

    USDA-ARS?s Scientific Manuscript database

    The field of high-content screening (HCS) typically uses measures of screen quality conceived for fairly straightforward high-throughput screening (HTS) scenarios. However, in contrast to HTS, image-based HCS systems rely on multidimensional readouts reporting biological responses associated with co...

  18. Cinema Screen Advertising: An Old Technology with New Promise for Consumer Marketing.

    ERIC Educational Resources Information Center

    Austin, Bruce A.

    Few individuals think of the theatrically exhibited motion picture as supported by advertising like other major forms of mass communications. Cinema screen advertising can be defined as the presentation of individual advertising messages on movie theatre screens in a distinct and discrete fashion. Screenvision ads run prior to the start of each…

  19. Hearing Screening Follow-Up: Completing the Process to Identify Hearing Health Needs

    ERIC Educational Resources Information Center

    Eiserman, William; Shisler, Lenore; Hoffman, Jeff

    2015-01-01

    Hearing is at the heart of language development and school readiness; increasing numbers of Early Head Start programs have come to rely on otoacoustic emissions (OAE) technology to screen all infants and toddlers for hearing loss. Successful identification of hearing health needs is dependent not only on an appropriate screening method, but also…

  20. Screening Intervals for Diabetic Retinopathy and Implications for Care.

    PubMed

    Scanlon, Peter H

    2017-09-05

    The purpose of this study is to review the evidence that lower risk groups who could safely be screened less frequently for sight-threatening diabetic retinopathy (DR) than annually. Data have demonstrated that people with no DR in either eye are at a low risk of progression to sight-threatening DR over a 2-year period (event rate 4.8 per 1000 person years), irrespective of whether the screening method is one-field non-mydriatic or two-field mydriatic digital photography. Low risk has been defined as no retinopathy on two consecutive screening episodes or no retinopathy on one screening episode combined with risk factor data. The risk of an extension to 2 years is less than 5 per 1000 person years in a population with a national screening programme, and the general standard of diabetes care is relatively good, whether low risk is defined as no retinopathy on two consecutive screening episodes or no retinopathy on one screening episode combined with other risk factor data. The definition used in different populations is likely to depend on the availability of data.

  1. Case study: impact of technology investment on lead discovery at Bristol-Myers Squibb, 1998-2006.

    PubMed

    Houston, John G; Banks, Martyn N; Binnie, Alastair; Brenner, Stephen; O'Connell, Jonathan; Petrillo, Edward W

    2008-01-01

    We review strategic approaches taken over an eight-year period at BMS to implement new high-throughput approaches to lead discovery. Investments in compound management infrastructure and chemistry library production capability allowed significant growth in the size, diversity and quality of the BMS compound collection. Screening platforms were upgraded with robust automated technology to support miniaturized assay formats, while workflows and information handling technologies were streamlined for improved performance. These technology changes drove the need for a supporting organization in which critical engineering, informatics and scientific skills were more strongly represented. Taken together, these investments led to significant improvements in speed and productivity as well a greater impact of screening campaigns on the initiation of new drug discovery programs.

  2. Copper Disk Manufactured at the Space Optics Manufacturing and Technology Center

    NASA Technical Reports Server (NTRS)

    1997-01-01

    This king-size copper disk, manufactured at the Space Optics Manufacturing and Technology Center (SOMTC) at the Marshall Space Flight Center (MSFC), is a special mold for making high resolution monitor screens. This master mold will be used to make several other molds, each capable of forming hundreds of screens that have a type of lens called a Fresnel lens. Weighing much less than conventional optics, Fresnel lenses have multiple concentric grooves, each formed to a precise angle, that together create the curvature needed to focus and project images. MSFC leads NASA's space optics manufacturing technology development as a technology leader for diamond turning. The machine used to manufacture this mold is among many one-of-a-kind pieces of equipment of MSFC's SOMTC.

  3. Assessment of automated disease detection in diabetic retinopathy screening using two-field photography.

    PubMed

    Goatman, Keith; Charnley, Amanda; Webster, Laura; Nussey, Stephen

    2011-01-01

    To assess the performance of automated disease detection in diabetic retinopathy screening using two field mydriatic photography. Images from 8,271 sequential patient screening episodes from a South London diabetic retinopathy screening service were processed by the Medalytix iGrading™ automated grading system. For each screening episode macular-centred and disc-centred images of both eyes were acquired and independently graded according to the English national grading scheme. Where discrepancies were found between the automated result and original manual grade, internal and external arbitration was used to determine the final study grades. Two versions of the software were used: one that detected microaneurysms alone, and one that detected blot haemorrhages and exudates in addition to microaneurysms. Results for each version were calculated once using both fields and once using the macula-centred field alone. Of the 8,271 episodes, 346 (4.2%) were considered unassessable. Referable disease was detected in 587 episodes (7.1%). The sensitivity of the automated system for detecting unassessable images ranged from 97.4% to 99.1% depending on configuration. The sensitivity of the automated system for referable episodes ranged from 98.3% to 99.3%. All the episodes that included proliferative or pre-proliferative retinopathy were detected by the automated system regardless of configuration (192/192, 95% confidence interval 98.0% to 100%). If implemented as the first step in grading, the automated system would have reduced the manual grading effort by between 2,183 and 3,147 patient episodes (26.4% to 38.1%). Automated grading can safely reduce the workload of manual grading using two field, mydriatic photography in a routine screening service.

  4. Automation for Crushing and Screening Equipment to Produce Graded Paving Crushed Stone

    NASA Astrophysics Data System (ADS)

    Tikhonov, Anatoly; Velichkin, Vladimir

    2017-10-01

    This paper offers analysis of factors related to production and storage of graded crushed stone, which adversely impact the service life and wear resistance of asphalt-concrete motor road pavements. The paper describes external and technology-related parameters that may cause changes of the preset ratio in graded crushed stone. Control factors are described that ensure the formulated fraction ratio in crushed stone by controlling the operation mode of the crushing and screening equipment. The paper also contains an ACS flow chart for crushing and screening equipment engaged in continuous closed-cycle two-stage technology. Performance of the ACS to maintain the preset fractionated crushed stone ratio has been confirmed with a mathematical model.

  5. Anchoring protein crystals to mounting loops with hydrogel using inkjet technology.

    PubMed

    Shinoda, Akira; Tanaka, Yoshikazu; Yao, Min; Tanaka, Isao

    2014-11-01

    X-ray crystallography is an important technique for structure-based drug discovery, mainly because it is the only technique that can reveal whether a ligand binds to the target protein as well as where and how it binds. However, ligand screening by X-ray crystallography involves a crystal-soaking experiment, which is usually performed manually. Thus, the throughput is not satisfactory for screening large numbers of candidate ligands. In this study, a technique to anchor protein crystals to mounting loops by using gel and inkjet technology has been developed; the method allows soaking of the mounted crystals in ligand-containing solution. This new technique may assist in the design of a fully automated drug-screening pipeline.

  6. Touch-screen technology for the dynamic display of -2D spatial information without vision: promise and progress.

    PubMed

    Klatzky, Roberta L; Giudice, Nicholas A; Bennett, Christopher R; Loomis, Jack M

    2014-01-01

    Many developers wish to capitalize on touch-screen technology for developing aids for the blind, particularly by incorporating vibrotactile stimulation to convey patterns on their surfaces, which otherwise are featureless. Our belief is that they will need to take into account basic research on haptic perception in designing these graphics interfaces. We point out constraints and limitations in haptic processing that affect the use of these devices. We also suggest ways to use sound to augment basic information from touch, and we include evaluation data from users of a touch-screen device with vibrotactile and auditory feedback that we have been developing, called a vibro-audio interface.

  7. Flooding tolerance of soybean (Glycine max) germplasm from southeast Asia under field and screen-house environment

    USDA-ARS?s Scientific Manuscript database

    Soybean (Glycine max L. Merr.) cultivars from the U.S. are generally intolerant to flooding stress. Soybean germplasm and cultivars originating from other countries and grown in rotations with paddy rice potentially could have better flooding tolerance. Screen-house and field tests were conducted to...

  8. Tuning the electronic properties of gated multilayer phosphorene: A self-consistent tight-binding study

    NASA Astrophysics Data System (ADS)

    Li, L. L.; Partoens, B.; Peeters, F. M.

    2018-04-01

    By taking account of the electric-field-induced charge screening, a self-consistent calculation within the framework of the tight-binding approach is employed to obtain the electronic band structure of gated multilayer phosphorene and the charge densities on the different phosphorene layers. We find charge density and screening anomalies in single-gated multilayer phosphorene and electron-hole bilayers in dual-gated multilayer phosphorene. Due to the unique puckered lattice structure, both intralayer and interlayer charge screenings are important in gated multilayer phosphorene. We find that the electric-field tuning of the band structure of multilayer phosphorene is distinctively different in the presence and absence of charge screening. For instance, it is shown that the unscreened band gap of multilayer phosphorene decreases dramatically with increasing electric-field strength. However, in the presence of charge screening, the magnitude of this band-gap decrease is significantly reduced and the reduction depends strongly on the number of phosphorene layers. Our theoretical results of the band-gap tuning are compared with recent experiments and good agreement is found.

  9. Emerging Technologies Look Deeper into the Eyes to Catch Signs of Disease

    MedlinePlus

    ... Eye Disease Vision Screening World Sight Day Emerging technologies look deeper into the eyes to catch signs ... to eye gazing Adaptive optics (AO) is one technology helping to overcome this problem. It deals with ...

  10. Biorefinery of the macroalgae Ulva lactuca: extraction of proteins and carbohydrates by mild disintegration.

    PubMed

    Postma, P R; Cerezo-Chinarro, O; Akkerman, R J; Olivieri, G; Wijffels, R H; Brandenburg, W A; Eppink, M H M

    2018-01-01

    The effect of osmotic shock, enzymatic incubation, pulsed electric field, and high shear homogenization on the release of water-soluble proteins and carbohydrates from the green alga Ulva lactuca was investigated in this screening study. For osmotic shock, both temperature and incubation time had a significant influence on the release with an optimum at 30 °C for 24 h of incubation. For enzymatic incubation, pectinase demonstrated being the most promising enzyme for both protein and carbohydrate release. Pulsed electric field treatment was most optimal at an electric field strength of 7.5 kV cm -1 with 0.05 ms pulses and a specific energy input relative to the released protein as low as 6.6 kWh kg prot -1 . Regarding literature, this study reported the highest protein (~ 39%) and carbohydrate (~ 51%) yields of the four technologies using high shear homogenization. Additionally, an energy reduction up to 86% was achieved by applying a novel two-phase (macrostructure size reduction and cell disintegration) technique.

  11. Digital Technology and Student Cognitive Development

    ERIC Educational Resources Information Center

    Cavanaugh, J. Michael; Giapponi, Catherine C.; Golden, Timothy D.

    2016-01-01

    Digital technology has proven a beguiling, some even venture addictive, presence in the lives of our 21st century (millennial) students. And while screen technology may offer select cognitive benefits, there is mounting evidence in the cognitive neuroscience literature that digital technology is restructuring the way our students read and think,…

  12. DEMONSTRATION BULLETIN: UNTERDUCK-VERDAMPFER- BRUNNEN TECHNOLOGY (UVB) VACUUM VAPORIZING WELL - ROY F. WESTON, INC./IEG TECHNOLOGIES CORPORATION

    EPA Science Inventory

    The Weston/IEG UVB technology is an in situ groundwater remediation technology that combines air-lift pumping and air stripping to clean aquifers contaminated with volatile organic compounds. A UVB system consists of a single well with two hydraulically separated screened interva...

  13. FlyRNAi.org—the database of the Drosophila RNAi screening center and transgenic RNAi project: 2017 update

    PubMed Central

    Hu, Yanhui; Comjean, Aram; Roesel, Charles; Vinayagam, Arunachalam; Flockhart, Ian; Zirin, Jonathan; Perkins, Lizabeth; Perrimon, Norbert; Mohr, Stephanie E.

    2017-01-01

    The FlyRNAi database of the Drosophila RNAi Screening Center (DRSC) and Transgenic RNAi Project (TRiP) at Harvard Medical School and associated DRSC/TRiP Functional Genomics Resources website (http://fgr.hms.harvard.edu) serve as a reagent production tracking system, screen data repository, and portal to the community. Through this portal, we make available protocols, online tools, and other resources useful to researchers at all stages of high-throughput functional genomics screening, from assay design and reagent identification to data analysis and interpretation. In this update, we describe recent changes and additions to our website, database and suite of online tools. Recent changes reflect a shift in our focus from a single technology (RNAi) and model species (Drosophila) to the application of additional technologies (e.g. CRISPR) and support of integrated, cross-species approaches to uncovering gene function using functional genomics and other approaches. PMID:27924039

  14. Walk through screening with multistatic mmW technology

    NASA Astrophysics Data System (ADS)

    Gumbmann, Frank; Ahmed, Sherif Sayed

    2016-10-01

    Active imaging systems for security screening at the airport or other checkpoints have proven to offer good results. Present systems require a specific position and posture,13 or a specific movement2 of the passenger in front of the imaging system. Walk Through Systems (WTS) which screen the passenger while passing the imaging system or a screening hallway would be more pleasant for the passenger and would result in a great improvement in the throughput. Furthermore the detection performance could be enhanced since possible threats are visible from different perspectives and could be tracked within different frames. The combination of all frames is equivalent to a full illumination of the passenger. This paper presents the concept of a WTS basing on a multistatic imaging system in the mmW range. The benefit is that the technology of existing portals can we reused and updated to a WTS. First results are demonstrated with an experimental system.

  15. Exploring the feasibility of alternative STD-testing venues and results delivery channels for a national screening campaign.

    PubMed

    Friedman, Allison L; Bloodgood, Bonny

    2013-01-01

    Annual chlamydia screening is recommended for sexually active women aged 25 years and younger, though less than half of eligible women are screened each year. If acceptable to young women, nontraditional testing venues and new communication technologies could promote efficiencies in sexually transmitted disease (STD) screening and facilitate screening by overcoming barriers at systems and patient levels. This study sought to explore young women's technology use, preferences for STD-testing venues, attitudes toward nontraditional venues, and acceptability of test results delivery options. A total of 80 ethnographic one-on-one telephone interviews were conducted with African American, Caucasian, and Latina women, aged 15 to 25 years, in 10 metropolitan areas of the United States. Interviews were recorded, transcribed, and analyzed using NVivo2. Alternative STD-testing venues and results delivery channels are valued by young women for their convenience and accessibility, but they must also offer privacy, confidentiality, and emotional/informational support to be acceptable. Assuring provider (or self) competence and valid/accurate test results is also important. Although new technologies have been embraced by young women for personal and social uses, they may not be as readily embraced for the provision of STD-related services. Additional social marketing efforts may be needed to promote acceptance of nontraditional STD-testing settings and results delivery methods.

  16. Novel screening techniques for ion channel targeting drugs

    PubMed Central

    Obergrussberger, Alison; Stölzle-Feix, Sonja; Becker, Nadine; Brüggemann, Andrea; Fertig, Niels; Möller, Clemens

    2015-01-01

    Ion channels are integral membrane proteins that regulate the flux of ions across the cell membrane. They are involved in nearly all physiological processes, and malfunction of ion channels has been linked to many diseases. Until recently, high-throughput screening of ion channels was limited to indirect, e.g. fluorescence-based, readout technologies. In the past years, direct label-free biophysical readout technologies by means of electrophysiology have been developed. Planar patch-clamp electrophysiology provides a direct functional label-free readout of ion channel function in medium to high throughput. Further electrophysiology features, including temperature control and higher-throughput instruments, are continually being developed. Electrophysiological screening in a 384-well format has recently become possible. Advances in chip and microfluidic design, as well as in cell preparation and handling, have allowed challenging cell types to be studied by automated patch clamp. Assays measuring action potentials in stem cell-derived cardiomyocytes, relevant for cardiac safety screening, and neuronal cells, as well as a large number of different ion channels, including fast ligand-gated ion channels, have successfully been established by automated patch clamp. Impedance and multi-electrode array measurements are particularly suitable for studying cardiomyocytes and neuronal cells within their physiological network, and to address more complex physiological questions. This article discusses recent advances in electrophysiological technologies available for screening ion channel function and regulation. PMID:26556400

  17. Novel screening techniques for ion channel targeting drugs.

    PubMed

    Obergrussberger, Alison; Stölzle-Feix, Sonja; Becker, Nadine; Brüggemann, Andrea; Fertig, Niels; Möller, Clemens

    2015-01-01

    Ion channels are integral membrane proteins that regulate the flux of ions across the cell membrane. They are involved in nearly all physiological processes, and malfunction of ion channels has been linked to many diseases. Until recently, high-throughput screening of ion channels was limited to indirect, e.g. fluorescence-based, readout technologies. In the past years, direct label-free biophysical readout technologies by means of electrophysiology have been developed. Planar patch-clamp electrophysiology provides a direct functional label-free readout of ion channel function in medium to high throughput. Further electrophysiology features, including temperature control and higher-throughput instruments, are continually being developed. Electrophysiological screening in a 384-well format has recently become possible. Advances in chip and microfluidic design, as well as in cell preparation and handling, have allowed challenging cell types to be studied by automated patch clamp. Assays measuring action potentials in stem cell-derived cardiomyocytes, relevant for cardiac safety screening, and neuronal cells, as well as a large number of different ion channels, including fast ligand-gated ion channels, have successfully been established by automated patch clamp. Impedance and multi-electrode array measurements are particularly suitable for studying cardiomyocytes and neuronal cells within their physiological network, and to address more complex physiological questions. This article discusses recent advances in electrophysiological technologies available for screening ion channel function and regulation.

  18. Development and application of a screening model for evaluating bioenhanced dissolution in DNAPL source zones

    NASA Astrophysics Data System (ADS)

    Phelan, Thomas J.; Abriola, Linda M.; Gibson, Jenny L.; Smits, Kathleen M.; Christ, John A.

    2015-12-01

    In-situ bioremediation, a widely applied treatment technology for source zones contaminated with dense non-aqueous phase liquids (DNAPLs), has proven economical and reasonably efficient for long-term management of contaminated sites. Successful application of this remedial technology, however, requires an understanding of the complex interaction of transport, mass transfer, and biotransformation processes. The bioenhancement factor, which represents the ratio of DNAPL mass transfer under microbially active conditions to that which would occur under abiotic conditions, is commonly used to quantify the effectiveness of a particular bioremediation remedy. To date, little research has been directed towards the development and validation of methods to predict bioenhancement factors under conditions representative of real sites. This work extends an existing, first-order, bioenhancement factor expression to systems with zero-order and Monod kinetics, representative of many source-zone scenarios. The utility of this model for predicting the bioenhancement factor for previously published laboratory and field experiments is evaluated. This evaluation demonstrates the applicability of these simple bioenhancement factors for preliminary experimental design and analysis, and for assessment of dissolution enhancement in ganglia-contaminated source zones. For ease of application, a set of nomographs is presented that graphically depicts the dependence of bioenhancement factor on physicochemical properties. Application of these nomographs is illustrated using data from a well-documented field site. Results suggest that this approach can successfully capture field-scale, as well as column-scale, behavior. Sensitivity analyses reveal that bioenhanced dissolution will critically depend on in-situ biomass concentrations.

  19. Trials and projects on cervical cancer and human papillomavirus prevention in sub-Saharan Africa.

    PubMed

    Adefuye, Peter O; Broutet, Nathalie J; de Sanjosé, Silvia; Denny, Lynette A

    2013-12-29

    Cervical cancer is the leading cause of cancer morbidity and mortality in women in sub-Saharan Africa (SSA), accounting for about 50,000 deaths annually. Until recently, cytology was the gold standard for screening and prevention of cervical cancer. This method of screening has not been successful in SSA due to a lack of human, financial and material resources and poor health care infrastructure. It is estimated that less than 5% of at risk women have ever being screened. In the past two decades alternative approaches to cytology for cervical cancer screening have been evaluated in low- and medium-income countries. Visual inspection with acetic acid (VIA) and/or Lugol's iodine (VILI) have been shown to have adequate sensitivity, although low specificity, in a number of cross-sectional research and demonstration projects. Visual inspection methods require minimal resources, are technologically accessible, and are feasible for screening for precancerous lesions. Linking screening with VIA/VILI to treatment with cryotherapy may enable screening and treatment to take place in one visit, but this is likely to result in large numbers of women being subjected to unnecessary treatment. A number of studies have shown that cryotherapy is not associated with significant side effects or complications and is well tolerated. Creating the infrastructure for screening of older women is considered desirable, despite the limitations of visual inspection methods as screening tests. Understanding the role of human papillomavirus (HPV) infection in the etiology of cervical cancer and the discovery of HPV rapid test kits, as well as the development of vaccines against the HPV oncogenic types, have created new opportunities for prevention of cervical cancer. Trials and projects have established (and are still ongoing) the feasibility of using these molecular tests for screening. The ultimate in prevention method is primary prevention, offered by the advent of prophylactic vaccines against the most important oncogenic types, namely HPV16 and 18. This article forms part of a regional report entitled "Comprehensive Control of HPV Infections and Related Diseases in the Sub-Saharan Africa Region" Vaccine Volume 31, Supplement 5, 2013. Updates of the progress in the field are presented in a separate monograph entitled "Comprehensive Control of HPV Infections and Related Diseases" Vaccine Volume 30, Supplement 5, 2012. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Genome-wide RNAi Screening to Identify Host Factors That Modulate Oncolytic Virus Therapy.

    PubMed

    Allan, Kristina J; Mahoney, Douglas J; Baird, Stephen D; Lefebvre, Charles A; Stojdl, David F

    2018-04-03

    High-throughput genome-wide RNAi (RNA interference) screening technology has been widely used for discovering host factors that impact virus replication. Here we present the application of this technology to uncovering host targets that specifically modulate the replication of Maraba virus, an oncolytic rhabdovirus, and vaccinia virus with the goal of enhancing therapy. While the protocol has been tested for use with oncolytic Maraba virus and oncolytic vaccinia virus, this approach is applicable to other oncolytic viruses and can also be utilized for identifying host targets that modulate virus replication in mammalian cells in general. This protocol describes the development and validation of an assay for high-throughput RNAi screening in mammalian cells, the key considerations and preparation steps important for conducting a primary high-throughput RNAi screen, and a step-by-step guide for conducting a primary high-throughput RNAi screen; in addition, it broadly outlines the methods for conducting secondary screen validation and tertiary validation studies. The benefit of high-throughput RNAi screening is that it allows one to catalogue, in an extensive and unbiased fashion, host factors that modulate any aspect of virus replication for which one can develop an in vitro assay such as infectivity, burst size, and cytotoxicity. It has the power to uncover biotherapeutic targets unforeseen based on current knowledge.

Top