MEETING DATA QUALITY OBJECTIVES WITH INTERVAL INFORMATION
Immunoassay test kits are promising technologies for measuring analytes under field conditions. Frequently, these field-test kits report the analyte concentrations as falling in an interval between minimum and maximum values. Many project managers use field-test kits only for scr...
Repeatability and validity of a field kit for estimation of cholinesterase in whole blood.
London, L; Thompson, M L; Sacks, S; Fuller, B; Bachmann, O M; Myers, J E
1995-01-01
OBJECTIVES--To evaluate a spectrophotometric field kit (Test-Mate-OP) for repeatability and validity in comparison with reference laboratory methods and to model its anticipated sensitivity and specificity based on these findings. METHODS--76 farm workers between the age of 20 and 55, of whom 30 were pesticide applicators exposed to a range of organophosphates in the preceding 10 days, had blood taken for plasma cholinesterase (PCE) and erythrocyte cholinesterase (ECE) measurement by field kit or laboratory methods. Paired blinded duplicate samples were taken from subgroups in the sample to assess repeatability of laboratory and field kit methods. Field kits were also used to test venous blood in one subgroup. The variance obtained for the field kit tests was then applied to two hypothetical scenarios that used published action guidelines to model the kit's sensitivity and specificity. RESULTS--Repeatability for PCE was much poorer and for ECE slightly poorer than that of laboratory measures. A substantial upward bias for field kit ECE relative to laboratory measurements was found. Sensitivity of the kit to a 40% drop in PCE was 67%, whereas that for ECE was 89%. Specificity of the kit with no change in mean of the population was 100% for ECE and 91% for PCE. CONCLUSION--Field kit ECE estimation seems to be sufficiently repeatable for surveillance activities, whereas PCE does not. Repeatability of both tests seems to be too low for use in epidemiological dose-response investigations. Further research is indicated to characterise the upward bias in ECE estimation on the kit. PMID:7697143
FUELS IN SOIL TEST KIT: FIELD USE OF DIESEL DOG SOIL TEST KITS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Unknown
2001-05-31
Western Research Institute (WRI) is commercializing Diesel Dog Portable Soil Test Kits for performing analysis of fuel-contaminated soils in the field. The technology consists of a method developed by WRI (U.S. Patents 5,561,065 and 5,976,883) and hardware developed by WRI that allows the method to be performed in the field (patent pending). The method is very simple and does not require the use of highly toxic reagents. The aromatic components in a soil extract are measured by absorption at 254 nm with a field-portable photometer. WRI added significant value to the technology by taking the method through the American Societymore » for Testing and Materials (ASTM) approval and validation processes. The method is designated ASTM Method D-5831-96, Standard Test Method for Screening Fuels in Soils. This ASTM designation allows the method to be used for federal compliance activities. In FY 99, twenty-five preproduction kits were successfully constructed in cooperation with CF Electronics, Inc., of Laramie, Wyoming. The kit components work well and the kits are fully operational. In the calendar year 2000, kits were provided to the following entities who agreed to participate as FY 99 and FY 00 JSR (Jointly Sponsored Research) cosponsors and use the kits as opportunities arose for field site work: Wyoming Department of Environmental Quality (DEQ) (3 units), F.E. Warren Air Force Base, Gradient Corporation, The Johnson Company (2 units), IT Corporation (2 units), TRC Environmental Corporation, Stone Environmental, ENSR, Action Environmental, Laco Associates, Barenco, Brown and Caldwell, Dames and Moore Lebron LLP, Phillips Petroleum, GeoSyntek, and the State of New Mexico. By early 2001, ten kits had been returned to WRI following the six-month evaluation period. On return, the components of all ten kits were fully functional. The kits were upgraded with circuit modifications, new polyethylene foam inserts, and updated instruction manuals.« less
FUELS IN SOIL TEST KIT: FIELD USE OF DIESEL DOG SOIL TEST KITS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Susan S. Sorini; John F. Schabron; Joseph F. Rovani, Jr.
Western Research Institute (WRI) has developed a new commercial product ready for technology transfer, the Diesel Dog{reg_sign} Portable Soil Test Kit, for performing analysis of fuel-contaminated soils in the field. The technology consists of a method developed by WRI (U.S. Patents 5,561,065 and 5,976,883) and hardware developed by WRI that allows the method to be performed in the field (patent pending). The method is very simple and does not require the use of highly toxic reagents. The aromatic components in a soil extract are measured by absorption at 254 nm with a field-portable photometer. WRI added significant value to themore » technology by taking the method through the American Society for Testing and Materials (ASTM) approval and validation processes. The method is designated as ASTM Method D 5831-96, Standard Test Method for Screening Fuels in Soils. This ASTM designation allows the method to be used for federal compliance activities. In June 2001, the Diesel Dog technology won an American Chemical Society Regional Industrial Innovations Award. To gain field experience with the new technology, Diesel Dog kits have been used for a variety of site evaluation and cleanup activities. Information gained from these activities has led to improvements in hardware configurations and additional insight into correlating Diesel Dog results with results from laboratory methods. The Wyoming Department of Environmental Quality (DEQ) used Diesel Dog Soil Test Kits to guide cleanups at a variety of sites throughout the state. ENSR, of Acton, Massachusetts, used a Diesel Dog Portable Soil Test Kit to evaluate sites in the Virgin Islands and Georgia. ChemTrack and the U.S. Army Corps of Engineers successfully used a test kit to guide excavation at an abandoned FAA fuel-contaminated site near Fairbanks, Alaska. Barenco, Inc. is using a Diesel Dog Portable Soil Test Kit for site evaluations in Canada. A small spill of diesel fuel was cleaned up in Laramie, Wyoming using a Diesel Dog Soil Test Kit.« less
EVALUATION OF A FIELD TEST KIT FOR MONITORING LEAD IN DRINKING WATER.
This article describes a conceptual framework for designing evaluation studies of test kits for the analysis of significant drinking water constituents. A commercial test kit for the analysis of lead in tap waters was evaluated and compared with a standard graphite furnace atomic...
Portable field kit for determining uranium in water
McHugh, John B.
1979-01-01
The pressing need for on-site field analyses of the uranium content of surface and ground waters has promoted the development of a simple, light-weight, relatively cheap, portable kit to make such determinations in the field. Forty to sixty water samples per day can be analyzed for uranium to less than 0.2 parts per billion. The kit was tested in the field with excellent results.
Accuracy of user-friendly blood typing kits tested under simulated military field conditions.
Bienek, Diane R; Charlton, David G
2011-04-01
Rapid user-friendly ABO-Rh blood typing kits (Eldon Home Kit 2511, ABO-Rh Combination Blood Typing Experiment Kit) were evaluated to determine their accuracy when used under simulated military field conditions and after long-term storage at various temperatures and humidities. Rates of positive tests between control groups, experimental groups, and industry standards were measured and analyzed using the Fisher's exact chi-square method to identify significant differences (p < or = 0.05). When Eldon Home Kits 2511 were used in various operational conditions, the results were comparable to those obtained with the control group and with the industry standard. The performance of the ABO-Rh Combination Blood Typing Experiment Kit was adversely affected by prolonged storage in temperatures above 37 degrees C. The diagnostic performance of commercial blood typing kits varies according to product and environmental storage conditions.
Shah, Manthan P; Shendell, Derek G; Meng, Qingyu; Ohman-Strickland, Pamela; Halperin, William
2018-04-23
The performances of a portable X-Ray Fluorescence (XRF) lead paint analyzer (RMD LPA-1, Protec Instrument Corp., Waltham, MA) and a commercially available colorimetric lead test kit (First Alert Lead Test Kit, eAccess Solutions, Inc., Palatine, IL) were evaluated for use by local or state health departments as potential cost-effective rapid analysis or "spot test" field techniques for tentative identification of lead content in sindoor powders. For both field-sampling methods, sensitivity, specificity and predictive values varied widely for samples containing <300,000 μg/g lead. For samples containing ≥300,000 μg/g lead, the aforementioned metrics were 100% (however, the CIs had a wide range). In addition, both field sampling methods showed clear, consistent positive readings only for samples containing ≥300,000 μg/g lead. Even samples with lead content as high as 5,110 μg/g were not positively identified by either field analysis technique. The results of this study suggest the XRF analyzer and colorimetric lead test kit cannot be used as a rapid field test for sindoor by health department inspectors.
A simple field kit for the determination of drug susceptibility in Plasmodium falciparum.
Nguyen-Dinh, P; Magloire, R; Chin, W
1983-05-01
A field kit has been developed which greatly simplifies the performance of the 48-hour in vitro test for drug resistance in Plasmodium falciparum. The kit uses an easily reconstituted lyophilized culture medium, and requires only a fingerprick blood sample. In parallel tests with 13 isolates of P. falciparum in Haiti, the new technique had a success rate equal to that of the previously described method, with comparable results in terms of parasite susceptibility in vitro to chloroquine and pyrimethamine.
Dumpster Optics: teaching and learning optics without a kit
NASA Astrophysics Data System (ADS)
Donnelly, Judy; Magnani, Nancy; Robinson, Kathleen
2016-09-01
The Next Generation Science Standards (NGSS) and renewed emphasis on STEM education in the U.S. have resulted in the development of many educational kits for teaching science in general and optics in particular. Many teachers do not have funding to purchase kits and practical experience has shown that even costly kits can have poorly written and misleading instructions and may include experiments that would not work in a classroom. Dumpster Optics lessons are designed to use inexpensive, commonly found materials. All lessons have been field-tested with students. We will describe the development of the lessons, provide examples of field testing experiences and outline possible future activities.
Chloride concentration gradients in tank-stored hydraulic fracturing fluids following flowback
Pamela J. Edwards; Linda L. Tracy; William K. Wilson
2011-01-01
A natural gas well in West Virginia was hydraulically fractured and the flowback was recovered and stored in an 18-foot-deep tank. Both in situ field test kit and laboratory measurements of electrical conductivity and chloride concentrations increased substantially with depth, although the laboratory measurements showed a greater increase. The field test kit also...
DOT National Transportation Integrated Search
2017-07-01
This study develops a Tailgate Test Kit to be used in the field to test flocculants for reducing turbidity in construction stormwater discharge. Turbidity of stormwater runoff at construction sites varies depending on which site soils are exposed to ...
Field kit and method for testing for the presence of gunshot residue
Rodacy, Philip J.; Walker, Pamela K.
2003-09-02
A field test kit for gunshot residue comprises a container having at least compartments separated by a barrier. A surface is tested by wiping it with a swab and placing the swab in a first compartment. The barrier is then breached, permitting reagent in the second compartment to flow onto the swab. The first compartment is transparent, and a color change will be observed if the reagent reacts with gunshot residue.
Evaluation of an arsenic test kit for rapid well screening in Bangladesh.
George, Christine Marie; Zheng, Yan; Graziano, Joseph H; Rasul, Shahriar Bin; Hossain, Zakir; Mey, Jacob L; van Geen, Alexander
2012-10-16
Exposure to arsenic in groundwater via drinking remains unabated for millions of villagers in Bangladesh. Since a blanket testing campaign using test kits almost a decade ago, millions of new wells have been installed but not tested; thus affordable testing is needed. The performance of the Arsenic Econo-Quick (EQ) kit was evaluated by blindly testing 123 wells in Bangladesh and comparing with laboratory measurements; 65 wells were tested twice. A subset of the same 123 wells was also tested using the Hach EZ kit in the field and the Digital Arsenator in the laboratory in Bangladesh. The EQ kit correctly determined the status of 110 (89%) and 113 (92%) out of 123 wells relative to the WHO guideline (10 μg/L) and the Bangladesh standard (50 μg/L), respectively. Relative to the WHO guideline, all misclassifications were underestimates for wells containing between >10 and 27 μg/L As. Relative to the Bangladesh As standard, over- and underestimates were evenly distributed. Given its short reaction time of 10 min relative to the Hach EZ and its lower cost compared to the Arsenator, the EQ kit appears to have several advantages for well testing in Bangladesh and elsewhere.
Evaluation of an Arsenic Test Kit for Rapid Well Screening in Bangladesh
George, Christine Marie; Zheng, Yan; Graziano, Joseph H; Rasul, Shahriar Bin; Hossain, Zakir; Mey, Jacob L; van Geen, Alexander
2013-01-01
Exposure to arsenic in groundwater via drinking remains unabated for millions of villagers in Bangladesh. Since a blanket testing campaign using test kits almost a decade ago, millions of new wells have been installed but not tested, thus affordable testing is needed. The performance of the Arsenic Econo-Quick (EQ) kit was evaluated by blindly testing 123 wells in Bangladesh and comparing with laboratory measurements; 65 wells were tested twice. A subset of the same 123 wells was also tested using the Hach EZ kit in the field and the Digital Arsenator in the laboratory in Bangladesh. The EQ kit correctly determined the status of 110 (89%) and 113 (92%) out of 123 wells relative to the WHO guideline (10 μg/L) and the Bangladesh standard (50 μg/L), respectively. Relative to the WHO guideline, all misclassifications were underestimates for wells containing between >10 and 27 μg/L As. Relative to the Bangladesh As standard, over- and under-estimates were evenly distributed. Given its short reaction time of 10 min relative to the Hach EZ and its lower cost compared to the Arsenator, the EQ kit appears to have several advantages for well testing in Bangladesh and elsewhere. PMID:22866936
A novel kit for rapid detection of Vibrio cholerae O1.
Hasan, J A; Huq, A; Tamplin, M L; Siebeling, R J; Colwell, R R
1994-01-01
We report on the development and testing of a novel, rapid, colorimetric immunodiagnostic kit, Cholera SMART, for direct detection of the presence of Vibrio cholerae O1 in clinical specimens. Unlike conventional culture methods requiring several days to complete, the Cholera SMART kit can be used directly in the field by untrained or minimally skilled personnel to detect V. cholerae O1 in less than 15 min, without cumbersome laboratory equipment. A total of 120 clinical and environmental bacterial strains, including both O1 and non-O1 serotypes of V. cholerae isolated from samples collected from a variety of geographical regions, were tested, and positive reactions were observed only with V. cholerae O1. Also, results of a field trial in Bangladesh, employing Cholera SMART, showed 100% specificity and 96% sensitivity compared with conventional culture methods. Another field trial, in Mexico, showed that Cholera SMART was 100% in agreement with a recently described coagglutination test when 108 stool specimens were tested.
Park, Douglas L; Coates, Scott; Brewer, Vickery A; Garber, Eric A E; Abouzied, Mohamed; Johnson, Kurt; Ritter, Bruce; McKenzie, Deborah
2005-01-01
Performance Tested Method multiple laboratory validations for the detection of peanut protein in 4 different food matrixes were conducted under the auspices of the AOAC Research Institute. In this blind study, 3 commercially available ELISA test kits were validated: Neogen Veratox for Peanut, R-Biopharm RIDASCREEN FAST Peanut, and Tepnel BioKits for Peanut Assay. The food matrixes used were breakfast cereal, cookies, ice cream, and milk chocolate spiked at 0 and 5 ppm peanut. Analyses of the samples were conducted by laboratories representing industry and international and U.S governmental agencies. All 3 commercial test kits successfully identified spiked and peanut-free samples. The validation study required 60 analyses on test samples at the target level 5 microg peanut/g food and 60 analyses at a peanut-free level, which was designed to ensure that the lower 95% confidence limit for the sensitivity and specificity would not be <90%. The probability that a test sample contains an allergen given a prevalence rate of 5% and a positive test result using a single test kit analysis with 95% sensitivity and 95% specificity, which was demonstrated for these test kits, would be 50%. When 2 test kits are run simultaneously on all samples, the probability becomes 95%. It is therefore recommended that all field samples be analyzed with at least 2 of the validated kits.
Portable thin layer chromatography for field detection of explosives and propellants
NASA Astrophysics Data System (ADS)
Satcher, Joe H.; Maienschein, Jon L.; Pagoria, Philip F.; Racoveanu, Ana; Carman, M. Leslie; Whipple, Richard E.; Reynolds, John G.
2012-06-01
A field deployable detection kit for explosives and propellants using thin layer chromatography (TLC) has been developed at Lawrence Livermore National Laboratory (LLNL). The chemistry of the kit has been modified to allow for field detection of propellants (through propellant stabilizers), military explosives, peroxide explosives, nitrates and inorganic oxidizer precursors. For many of these target analytes, the detection limit is in the μg to pg range. A new miniaturized, bench prototype, field portable TLC (Micro TLC) kit has also been developed for the detection and identification of common military explosives. It has been demonstrated in a laboratory environment and is ready for field-testing. The kit is comprised of a low cost set of commercially available components specifically assembled for rapid identification needed in the field and identifies the common military explosives: HMX, RDX, Tetryl, Explosive D or picric acid, and TNT all on one plate. Additional modifications of the Micro TLC system have been made with fluorescent organosilicon co-polymer coatings to detect a large suite of explosives.
NASA Astrophysics Data System (ADS)
Astutik, J.
2017-02-01
Food additives are materials that can not be separated from the lives of students and the community. Based on the preliminary questionnaire, it indicates the lack of kit supporting material additives in some schools and communities. The research objectives of this development are (1) to develop Kit experiment (SAYOFU KIT) and supplementary books to improve student learning outcomes in the classroom and public awareness on food additives (2) to describe the feasibility and potential effectiveness of SAYOFU KIT developed (3) to analyze the practice of SAYOFU KIT and benefits for students and the community. This development study uses 4-D models Thiagarajan, et al (1974). Through some stages, they are: defining, designing, developing and disseminating which involes the students and community. The developed SAYOFU KIT includes additives sample kit, borax test kit, curcumin test kit, formaldehyde test kit, modification heater to the identification of dyes and dye test paper. The study is conducted at SMP Plus Hidayatul Mubtadiin, and TKIT Al Uswah. The products are validated by experts and education practitioners. Qualitative data processing uses descriptive method, whereas quantitative data by using the N-gain. The average yield of expert validation of SAYOFU KIT with supplementary books 76.50% teacher’s book and 76.30% student’s book are eligible. The average yield of 96.81% validation of educational practitioners criteria, piloting a small group of 83.15%, and 82.89% field trials are very decent. The average yield on the student questionnaire responses SAYOFU kit and supplementary book is 87.6% with the criteria very well worth it. N-Gain 0:56 cognitive achievement with the criteria enough. The results of the public poll showed 95% feel the benefits SAYOFU kits for testing food. Based from description indicates that SAYOFU Kit developed feasible, practical, useful to support inquiry learning and improve student learning outcomes as well as public awareness of food additives.
Low-cost field test kits for arsenic detection in water.
Das, Joyati; Sarkar, Priyabrata; Panda, Jigisha; Pal, Priyabrata
2014-01-01
Arsenic, a common contaminant of groundwater, affects human health adversely. According to the World Health Organization (WHO), the maximum recommended contamination level of arsenic in drinking water is 10 μg/L. The purpose of this research was to develop user-friendly kits for detection of arsenic to measure at least up to 10 μg/L in drinking water, so that a preventive measure could be taken. Two different kits for detection of total arsenic in water are reported here. First, the arsenic in drinking water was converted to arsine gas by a strong reducing agent. The arsine produced was then detected by paper strips via generation of color due to reaction with either mercuric bromide (KIT-1) or silver nitrate (KIT-2). These were previously immobilized on the detector strip. The first one gave a yellow color and the second one grey. Both of these kits could detect arsenic contamination within a range of 10 μg/L-250 μg/L. The detection time for both the kits was only 7 min. The kits exhibited excellent performance compared to other kits available in the market with respect to detection time, ease of operation, cost and could be easily handled by a layman. The field trials with these kits gave very satisfactory results. A study on interference revealed that these kits could be used in the presence of 24 common ions present in the arsenic contaminated water. Though the kits were meant for qualitative assay, the results with unknown concentrations of real samples, when compared with atomic absorption spectrophotometer (AAS) were in good agreement as revealed by the t-test.
A cost effective hydrogel test kit for pre and post blast trinitrotoluene.
Choodum, Aree; Malathong, Khanitta; NicDaeid, Niamh; Limsakul, Wadcharawadee; Wongniramaikul, Worawit
2016-09-01
A cost effective hydrogel test kit was successfully developed for the detection of pre- and post-blast trinitrotoluene (TNT). A polyvinyl alcohol (PVA) hydrogel matrix was used to entrap the potassium hydroxide (KOH) colourimetric reagent. The easily portable test kit was fabricated in situ in a small tube to which the sample could be added directly. The test kit was used in conjunction with digital image colourimetry (DIC) to demonstrate the rapid quantitative analysis of TNT in a test soil sample. The built-in digital camera of an iPhone was used to capture digital images of the colourimetric products from the test kit. Red-Green-Blue (RGB) colour data from the digital images of TNT standard solutions were used to establish a calibration graph. The validation of the DIC method indicated excellent inter day precision (0.12-3.60%RSD) and accuracy (93-108% relative accuracy). Post-blast soil samples containing TNT were analysed using the test kit and were in good agreement with spectrophotometric analysis. The intensity of the RGB data from the TNT complex deviated by +6.3%, +5.1%, and -4.9% after storage of the test kits in a freezer for 3 months. The test kit was also reusable for up to 12 times with only -5.4%, +0.3%, and +4.0% deviations. The hydrogel test kit was applied in the detection of trace explosive residues at the scene of the recent Bangkok bombing at the Ratchaprasong intersection and produced positive results for TNT demonstrating its operational field application as a rapid and cost effective quantitative tool for explosive residue analysis. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
An Evaluation of Blood Cholinesterase Testing Methods for Military Health
2008-05-01
activity found that only one device has been validated for ChE testing in the field: the Model 400 Test-mate™ ChE kit by EQM Research, Inc. (Cincinnati...OH). Suggested future modifications to the Model 400 Test-mate™ ChE kit include displaying/recording of acetyl-ChE activity uncorrected for...cholinesterase activity , that are routinely monitored by the Department of Defense (DoD). Within DoD, definitive cholinesterase testing is conducted by
site LAB(& Analytical Test Kit UVF-3 I OOA (UVF-3 I OOA) developed by siteLABqD Corporation (siteLABa)) was demonstrated under the U.S. Environmental Protection Agency Superfund Innovative Technology Evaluation Program in June 2000 at the Navy Base Ventura County site in ...
Campbell, Rebecca; Pierce, Steven J; Sharma, Dhruv B; Shaw, Jessica; Feeney, Hannah; Nye, Jeffrey; Schelling, Kristin; Fehler-Cabral, Giannina
2017-01-01
A growing number of U.S. cities have large numbers of untested sexual assault kits (SAKs) in police property facilities. Testing older kits and maintaining current case work will be challenging for forensic laboratories, creating a need for more efficient testing methods. We evaluated selective degradation methods for DNA extraction using actual case work from a sample of previously unsubmitted SAKs in Detroit, Michigan. We randomly assigned 350 kits to either standard or selective degradation testing methods and then compared DNA testing rates and CODIS entry rates between the two groups. Continuation-ratio modeling showed no significant differences, indicating that the selective degradation method had no decrement in performance relative to customary methods. Follow-up equivalence tests indicated that CODIS entry rates for the two methods could differ by more than ±5%. Selective degradation methods required less personnel time for testing and scientific review than standard testing. © 2016 American Academy of Forensic Sciences.
Merrill, Rebecca D.; Shamim, Abu Ahmed; Ali, Hasmot; Schulze, Kerry; Rashid, Mahbubur; Christian, Parul; West, Jr., Keith P.
2009-01-01
Iron is ubiquitous in natural water sources used around the world for drinking and cooking. The health impact of chronic exposure to iron through water, which in groundwater sources can reach well above the World Health Organization's defined aesthetic limit of 0.3 mg/L, is not currently understood. To quantify the impact of consumption of iron in groundwater on nutritional status, it is important to accurately assess naturally-occurring exposure levels among populations. In this study, the validity of iron quantification in water was evaluated using two portable instruments: the HACH DR/890 portable colorimeter (colorimeter) and HACH Iron test-kit, Model IR-18B (test-kit), by comparing field-based iron estimates for 25 tubewells located in northwestern Bangladesh with gold standard atomic absorption spectrophotometry analysis. Results of the study suggest that the HACH test-kit delivers more accurate point-of-use results across a wide range of iron concentrations under challenging field conditions. PMID:19507757
Merrill, Rebecca D; Shamim, Abu Ahmed; Labrique, Alain B; Ali, Hasmot; Schulze, Kerry; Rashid, Mahbubur; Christian, Parul; West, Keith P
2009-06-01
Iron is ubiquitous in natural water sources used around the world for drinking and cooking. The health impact of chronic exposure to iron through water, which in groundwater sources can reach well above the World Health Organization's defined aesthetic limit of 0.3 mg/L, is not currently understood. To quantify the impact of consumption of iron in groundwater on nutritional status, it is important to accurately assess naturally-occurring exposure levels among populations. In this study, the validity of iron quantification in water was evaluated using two portable instruments: the HACH DR/890 portable colorimeter (colorimeter) and HACH Iron test-kit, Model IR-18B (test-kit), by comparing field-based iron estimates for 25 tubewells located in northwestern Bangladesh with gold standard atomic absorption spectrophotometry analysis. Results of the study suggest that the HACH test-kit delivers more accurate point-of-use results across a wide range of iron concentrations under challenging field conditions.
Evaluation of a culture-based pathogen identification kit for bacterial causes of bovine mastitis.
Viora, L; Graham, E M; Mellor, D J; Reynolds, K; Simoes, P B A; Geraghty, T E
2014-07-26
Accurate identification of mastitis-causing bacteria supports effective management and can be used to implement selective use of antimicrobials for treatment. The objectives of this study were to compare the results from a culture-based mastitis pathogen detection test kit ('VetoRapid', Vétoquinol) with standard laboratory culture and to evaluate the potential suitability of the test kit to inform a selective treatment programme. Overall 231 quarter milk samples from five UK dairy farms were collected. The sensitivity and specificity of the test kit for the identification of Escherichia coli, Staphylococcus aureus, coagulase-negative staphylococci, Streptococcus uberis and Enterococcus spp. ranged from 17 per cent to 84 per cent and 92 per cent to 98 per cent, respectively. In total, 23 of 68 clinical samples were assigned as meeting the requirement for antimicrobial treatment (Gram-positive organism cultured) according to standard culture results, with the test kit results having sensitivity and specificity of 91 per cent and 78 per cent, respectively. Several occurrences of misidentification are reported, including S. aureus being misidentified as coagulase-negative staphylococci and vice versa. The test kit provides rapid preliminary identification of five common causes of bovine mastitis under UK field conditions and is likely to be suitable for informing selective treatment of clinical mastitis caused by Gram-positive organisms. British Veterinary Association.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Preston, D.R.; Schaub, S.A.
1991-09-01
A literature and market search of existing technology for the detection, identification, and quantification of microorganisms in water was conducted. Based upon the availability of technologies and their configurations, an assessment of the appropriate strategies to pursue for the near and long term development plans in development of the Rapid Field Bacteriology Test Kit was performed. Near term technologies to improve the Army's capability to detect microorganisms would appear to be essentially improvements in versatility and measurement of coliform indicator organisms. New chromogenic and fluorogenic indicator substances associated with new substrates appear to be best suited for test kit developmentmore » either for quantitative membrane filter tests or presence/absence and multiple fermentation tests. Test times, incubator requirements, and operator involvement appear to be similar to older technologies. Long term development would appear to favor such technologies as genetic probes with amplification of the hydridized nucleic acid materials of positive samples, and some immunological based systems such as enzyme linked, immuno-sorbent assays. In both cases, the major problems would appear to be sample preparation and development of signal strengths from the reactions which would allow the user to see results in 1 hour.« less
Wide, Leif
2005-01-01
The universities are encouraged by the government nowadays to stimulate innovations and also to provide the proper machinery for assisting the protection and commercialisation of innovations. A better understanding of the innovation process may help to create an atmosphere suitable for inventions at the university. Examples can be taken from successful innovations previously made at the university. During the 1960's I made a series of inventions, which ultimately led to the development of the diagnostic test kit industry. The first, which I made as an undergraduate, was a simple and reliable test kit for diagnosis of pregnancy. This was followed by the solid phase radioimmunoassay and a solid phase assay for vitamin B12; next, the dual specific non-competitive sandwich assay and the in-vitro test for diagnosis of allergy, called RAST (Radioallergosorbent test). Organon in Holland with the pregnancy test kit, and Pharmacia in Sweden with test kits for radioimmunoassay, became pioneers among the diagnostic test kit industries. Pharmacia Diagnostics later became one of the leading diagnostic test kit companies in the world and has continued to be so in the field of allergy diagnosis. Each one of these inventions started with a few unique observations leading to a technical development. The pregnancy test as well as the allergy test emerged from the development of assay methods with unique qualities with the subsequent search for appropriate applications. The foreseeing of a commercial value on a future market was a very important step. This was followed by the search for a suitable industry interested to exploit the invention with its new business opportunity i.e. apply for a patent, produce and market the products, which in my case consisted of the necessary reagents and equipments for particular diagnostic tests. Finally, an agreement had to be settled between the entrepreneur and the inventors. This report describes these inventions and particularly discusses some crucial steps of the innovation processes.
Catomeris, Peter; Baxter, Nancy N; Boss, Sheila C; Paszat, Lawrence F; Rabeneck, Linda; Randell, Edward; Serenity, Mardie L; Sutradhar, Rinku; Tinmouth, Jill
2018-01-01
- Although promising for colorectal cancer screening, hemoglobin (Hb) stability remains a concern with fecal immunochemical tests. This study implemented a novel, standardized method to compare Hb stability across various fecal immunochemical tests. The method can be used to inform decisions when selecting a kit for use in colorectal cancer screening. In so doing, this work addressed a critical need for standardization in this field. - To compare the stability of Hb across 5 different immunochemical kits and one guaiac kit. - The stability of Hb was analyzed in collection devices inoculated with Hb-spiked feces and (1) stored at various temperatures (frozen, refrigerated, ambient, and elevated) for more than 60 days; (2) after undergoing 3 controlled, freeze-thaw cycles; and (3) after being transported by courier or postal services in uncontrolled temperature conditions from 3 locations in Ontario, Canada, to a central testing center. - The stability of Hb varied with time and temperature and by kit. Lower Hb recoveries occurred with increasing temperature and increasing time from sample collection to testing. Refrigeration provided the best stability, although results varied across kits (eg, from 4.2 days to >60 days before a prespecified threshold [<70% probability of the test results remaining positive] was reached). Freeze-thaw stability varied across kits and cycles (Hb recoveries: NS Plus [Alfresa Pharma, Chuo-ku, Osaka, Japan], 91.7% to 95.4%; OC Diana [Eiken Chemical, Taito-ku, Tokyo, Japan], 57.6% to 74.9%). Agreement regarding Hb levels before and after transportation varied across kits (from 57% to 100%). - Important differences in Hb stability were found across the included fecal immunochemical tests. These findings should inform practice-based and population-based colorectal cancer screening.
A Team Approach to Management by Objectives with Special Emphasis on Managerial Self-Evaluation.
ERIC Educational Resources Information Center
Alvir, Howard P.
This kit contains everything needed to explain, criticize and plan, simulate, and evaluate a management by objectives (MBO) program. The kit has been field tested in state agencies, schools, businesses, and volunteer organizations. Rather than present only the strengths of MBO, this program defines MBO, presents its strong points in discussing the…
Stability of user-friendly blood typing kits stored under typical military field conditions.
Bienek, Diane R; Chang, Cheow K; Charlton, David G
2009-10-01
To help preserve in-theater strength within deployed military units, commercially available, rapid, user-friendly ABO-Rh blood typing kits were evaluated to determine their stability in storage conditions commonly encountered by the warfighter. Methods for environmental exposure testing were based on MIL-STD-810F. When Eldon Home Kits 2511 were exposed to various temperature/relative humidity conditions, the results were comparable to those obtained with the control group and those obtained with industry-standard methods. For the ABO-Rh Combination Blood Typing Experiment Kits, 2 of the exposure treatments rendered them unusable. In addition, a third set of exposure treatments adversely affected the kits, resulting in approximately 30% blood type misclassifications. Collectively, this evaluation of commercial blood typing kits revealed that diagnostic performance can vary between products, lots, and environmental storage conditions.
Development and validation of an ELISA kit (YF MAC-HD) to detect IgM to yellow fever virus.
Basile, Alison Jane; Goodman, Christin; Horiuchi, Kalanthe; Laven, Janeen; Panella, Amanda J; Kosoy, Olga; Lanciotti, Robert S; Johnson, Barbara W
2015-12-01
Yellow fever virus (YFV) is endemic in tropical and sub-tropical regions of the world, with around 180,000 human infections a year occurring in Africa. Serologic testing is the chief laboratory diagnostic means of identifying an outbreak and to inform the decision to commence a vaccination campaign. The World Health Organization disseminates the reagents for YFV testing to African reference laboratories, and the US Centers for Disease Control and Prevention (CDC) is charged with producing and providing these reagents. The CDC M-antibody capture ELISA is a 2-day test, requiring titration of reagents when new lots are received, which leads to inconsistency in testing and wastage of material. Here we describe the development of a kit-based assay (YF MAC-HD) based upon the CDC method, that is completed in approximately 3.5h, with equivocal samples being reflexed to an overnight protocol. The kit exhibits >90% accuracy when compared to the 2-day test. The kits were designed for use with a minimum of equipment and are stored at 4°C, removing the need for freezing capacity. This kit is capable of tolerating temporary sub-optimal storage conditions which will ease shipping or power outage concerns, and a shelf life of >6 months was demonstrated with no deterioration in accuracy. All reagents necessary to run the YF MAC-HD are included in the kit and are single-use, with 8 or 24 sample options per kit. Field trials are envisioned for the near future, which will enable refinement of the method. The use of the YF MAC-HD is anticipated to reduce materials wastage, and improve the quality and consistency of YFV serologic testing in endemic areas. Published by Elsevier B.V.
SensorKit: An End-to-End Solution for Environmental Sensor Networking
NASA Astrophysics Data System (ADS)
Silva, F.; Graham, E.; Deschon, A.; Lam, Y.; Goldman, J.; Wroclawski, J.; Kaiser, W.; Benzel, T.
2008-12-01
Modern day sensor network technology has shown great promise to transform environmental data collection. However, despite the promise, these systems have remained the purview of the engineers and computer scientists who design them rather than a useful tool for the environmental scientists who need them. SensorKit is conceived of as a way to make wireless sensor networks accessible to The People: it is an advanced, powerful tool for sensor data collection that does not require advanced technological know-how. We are aiming to make wireless sensor networks for environmental science as simple as setting up a standard home computer network by providing simple, tested configurations of commercially-available hardware, free and easy-to-use software, and step-by-step tutorials. We designed and built SensorKit using a simplicity-through-sophistication approach, supplying users a powerful sensor to database end-to-end system with a simple and intuitive user interface. Our objective in building SensorKit was to make the prospect of using environmental sensor networks as simple as possible. We built SensorKit from off the shelf hardware components, using the Compact RIO platform from National Instruments for data acquisition due to its modular architecture and flexibility to support a large number of sensor types. In SensorKit, we support various types of analog, digital and networked sensors. Our modular software architecture allows us to abstract sensor details and provide users a common way to acquire data and to command different types of sensors. SensorKit is built on top of the Sensor Processing and Acquisition Network (SPAN), a modular framework for acquiring data in the field, moving it reliably to the scientist institution, and storing it in an easily-accessible database. SPAN allows real-time access to the data in the field by providing various options for long haul communication, such as cellular and satellite links. Our system also features reliable data storage and transmission, using a custody transfer mechanism that ensures data is retained until successful delivery to the scientist can be confirmed. The ability for the scientist to communicate in real-time with the sensor network in the field enables remote sensor reconfiguration and system health and status monitoring. We use a spiral approach of design, test, deploy and revise, and, by going to the field frequently and getting feedback from field scientists, we have been able to include additional functionality that is useful to the scientist while ensuring SensorKit remains intuitive to operate. Users can configure, control, and monitor SensorKit using a number of tools we have developed. An intuitive user interface running on a desktop or laptop allows scientists to setup the system, add and configure sensors, and specify when and how the data will be collected. We also have a mobile version of our interface that runs on a PDA and lets scientists calibrate sensors and "tune" the system while in the field, allowing for data validation before leaving the field and returning to the research lab. SensorKit also features SensorBase, an intuitive user interface built on top of a standard SQL database, which allows scientists to store and share their data with other researchers. SensorKit has been used for diverse scientific applications and deployed throughout the world: from studying mercury cycling in rice paddies in China, to ecological research in the neotropical rainforests of Costa Rica, to monitoring the contamination of salt lakes in Argentina.
Bienek, Diane R; Charlton, David G
2012-05-01
Being able to test for the presence of blood pathogens at forward locations could reduce morbidity and mortality in the field. Rapid, user-friendly blood typing kits for detecting Human Immunodeficiency Virus (HIV), Hepatitis C Virus (HCV), and Hepatitis B Virus (HBV) were evaluated to determine their accuracy after storage at various temperatures/humidities. Rates of positive tests of control groups, experimental groups, and industry standards were compared (Fisher's exact chi2, p < or = 0.05). Compared to the control group, 2 of 10 HIV detection devices were adversely affected by exposure to high temperature/high humidity or high temperature/low humidity. With one exception, none of the environmentally exposed HCV or HBV detection devices exhibited significant differences compared to those stored under control conditions. For HIV, HCV, and HBV devices, there were differences compared to the industry standard. Collectively, this evaluation of pathogen detection kits revealed that diagnostic performance varies among products and storage conditions, and that the tested products cannot be considered to be approved for use to screen blood, plasma, cell, or tissue donors.
Hasan, J A; Huq, A; Nair, G B; Garg, S; Mukhopadhyay, A K; Loomis, L; Bernstein, D; Colwell, R R
1995-11-01
We report on the development and testing of two monoclonal antibody-based rapid immunodiagnostic test kits, BengalScreen, a coagglutination test, and Bengal DFA, a direct fluorescent-antibody test, for direct detection of Vibrio cholerae O139 synonym Bengal in clinical and environmental specimens. The BengalScreen test requires less than 5 min to complete and can be used in the field. Bengal DFA, being more sensitive than BengalScreen, requires only one reagent and less than 20 min for detection and enumeration of V. cholerae O139 synonym Bengal. In tests for specificity, all 40 strains of V. cholerae O139 reacted with both test kits, whereas 157 strains of heterologous species examined did not, yielding 100% specificity in this study. A field trial was conducted in with both BengalScreen and Bengal DFA, and the results were compared with those obtained by conventional culture methods. BengalScreen demonstrated a sensitivity of 95%, a specificity of 100%, a positive predictive value of 100%, and a negative predictive value of 94%. Results obtained by Bengal DFA, on the other hand, were 100% sensitive and 100% specific and yielded 100% positive and negative predictive values compared with culture methods. In a second evaluation, 93 stool specimens from Mexico that were negative for V. cholerae O139 by culture were also tested with both the BengalScreen and Bengal DFA kits. None of the 93 specimens were positive for V. cholerae O139 by both tests. A concentration method was optimized for screening of environmental water samples for V. cholerae O139 synonym Bengal with rapid test kits. BengalScreen results were unequivocally positive when water samples contained at least 2.0 x 10(3) CFU/ml, whereas Bengal DFA demonstrated an unequivocally positive reaction when the water sample contained at least 1.5 x 10(2) CFU/ml. When Bengal DFA was compared with conventional culture methods for enumeration of V. cholerae O139 synonym Bengal organisms, no difference was observed.
Validation of spot-testing kits to determine iodine content in salt.
Pandav, C. S.; Arora, N. K.; Krishnan, A.; Sankar, R.; Pandav, S.; Karmarkar, M. G.
2000-01-01
Iodine deficiency disorders are a major public health problem, and salt iodization is the most widely practised intervention for their elimination. For the intervention to be successful and sustainable, it is vital to monitor the iodine content of salt regularly. Iodometric titration, the traditional method for measuring iodine content, has problems related to accessibility and cost. The newer spot-testing kits are inexpensive, require minimal training, and provide immediate results. Using data from surveys to assess the availability of iodized salt in two states in India, Madhya Pradesh and the National Capital Territory of Delhi, we tested the suitability of such a kit in field situations. Salt samples from Delhi were collected from 30 schools, chosen using the Expanded Programme on Immunization (EPI) cluster sampling technique. A single observer made the measurement for iodine content using the kit. Salt samples from Madhya Pradesh were from 30 rural and 30 urban clusters, identified by using census data and the EPI cluster sampling technique. In each cluster, salt samples were collected from 10 randomly selected households and all retailers. The 15 investigators performing the survey estimated the iodine content of salt samples in the field using the kit. All the samples were brought to the central laboratory in Delhi, where iodine content was estimated using iodometric titration as a reference method. The agreement between the kit and titration values decreased as the number of observers increased. Although sensitivity was not much affected by the increase in the number of observers (93.3% for a single observer and 93.9% for multiple observers), specificity decreased sharply (90.4% for a single observer and 40.4% for multiple observers). Due to the low specificity and resulting high numbers of false-positives for the kit when used by multiple observers ("real-life situations"), kits were likely to consistently overestimate the availability of iodized salt. This overestimation could result in complacency. Therefore, we conclude that until a valid alternative is available, the titration method should be used for monitoring the iodine content of salt at all levels, from producer to consumer, to ensure effectiveness of the programme. PMID:10994281
Fort Dix Remedial Investigation/Feasibility Study for MAG-1 Area
1994-01-01
by PID headspace results or odor ), samples should be diluted to bring the target compound concentrations within the instrument calibration range...Conductivity Testing ................... 2-38 2.9 ANALYTICAL PROCEDURES FOR FIELD SCREENING SAMPLES .. 2-38 2.9.1 Volatile Organic Compounds ...ANALYSIS OF VOLATILE ORGANIC COMPOUNDS BY FIELD GAS CHROMATOGRAPHY - STANDARD OPERATING PROCEDURE APPENDIX B RDX EXPLOSIVES FIELD TEST KIT PROCEDURES
Sassen, J
2000-08-01
Livestock health care service is very much involved and interested in surveillance of the drinking water as well. However, in order to examine the water immediately "on the fly", test kits have to be provided, which offer results comparable to these obtained in the laboratories according to official prescription. The German Army was confronted with a similar situation during the secently performed mission in crisis regions. At the early state of a mission usually laboratory equipment is not yet established. Therefore a set of test kits was compiled suitable for mobile microbiological examination of drinking water. This set was excessively examined comparison with reference methods. In conclusion it is shown, that the mobile set gains equal or even better results compared to those obtained according to legally prescribed standard procedures.
Litster, A L; Pressler, B; Volpe, A; Dubovi, E
2012-08-01
Canine parvovirus (CPV) and canine distemper virus (CDV) are highly infectious and often fatal diseases with worldwide distributions, and are important population management considerations in animal shelters. A point-of-care ELISA test kit is available to detect serum antibodies to CPV and CDV, and presumptively to predict protective status. The aim of this study was to determine the diagnostic accuracy of the test compared to CPV hemagglutination inhibition titers and CDV serum neutralization titers determined by a reference laboratory, using sera collected from dogs housed at animal shelters. The ELISA test was used under both field and laboratory conditions and duplicate specimens were processed using an extra wash step. The test kit yielded accurate results (CPV: sensitivity 92.3%, specificity 93.5%; CDV: sensitivity 75.7%, specificity 91.8%) under field conditions. CDV sensitivity was improved by performing the test under laboratory conditions and using an optical density (OD) meter (laboratory performed 94.0%; OD 88.1%). Point-of-care ELISA testing for serum CPV and CDV antibody titers was demonstrated to be a useful tool for determining antibody status when making decisions regarding the need for CPV and/or CDV vaccination and also in animal shelters for population management. Copyright © 2012 Elsevier Ltd. All rights reserved.
An Evaluation of the NIDS (registered trademark) ACE (trademark) Test
2014-06-30
included chemicals commonly used for drinking water disinfection (chlorine and chloramine), byproducts of cyanobacteria blooms (geosmin and 2...duration field toxicity test for Army drinking water . One component of the ESB the ACE Test) is an enzymatic assay designed to detect neurotoxicants...adverse health effects is the presence of toxic industrial chemicals (TICs) in drinking water . The current field water test kit – the water quality
Hagiwara, Ken'ichi; Iwamaru, Yoshifumi; Tabeta, Naoko; Yokoyama, Takashi; Tobiume, Minoru
2017-03-04
A classical type of bovine spongiform encephalopathy (C-BSE), recognized in 1987, had a large impact on public health due to its zoonotic link to variant Creutzfeldt-Jakob disease by the human consumption of dietary products contaminated with the C-BSE prion. Thus, a number of countries implemented BSE surveillance using rapid post-mortem test kits that were approved for detection of the C-BSE prion in the cattle brain. However, as atypical BSE (L- and H-BSE) cases emerged in subsequent years, the efficacy of the kits for the detection of atypical BSE prions became a matter of concern. In response to this, laboratories in the European Union and Canada evaluated the kits used in their countries. Here, we carried out an evaluation study of NippiBL®, a kit currently used for BSE screening in Japan. By applying the kit to cattle brains of field cases of C-BSE and L-BSE, and an experimental case of H-BSE, we showed its comparable sensitivities to C, L-, and H-BSE prions, and satisfactory performance required by the European Food Safety Authority. In addition to NippiBL®, two kits (TeSeE® and FRELISA®) formerly used in Japan were effective for detection of the L-BSE prion, although the two kits were unable to be tested for the H-BSE prion due to the discontinuation of domestic sales during this study. These results indicate that BSE screening in Japan is as effective as those in other countries, and it is unlikely that cases of atypical BSE have been overlooked.
Thongdee, Pimwan; Chaijaroenkul, Wanna; Kuesap, Jiraporn; Na-Bangchang, Kesara
2014-08-01
Microscopy is considered as the gold standard for malaria diagnosis although its wide application is limited by the requirement of highly experienced microscopists. PCR and serological tests provide efficient diagnostic performance and have been applied for malaria diagnosis and research. The aim of this study was to investigate the diagnostic performance of nested PCR and a recently developed an ELISA-based new rapid diagnosis test (RDT), NovaLisa test kit, for diagnosis of malaria infection, using microscopic method as the gold standard. The performance of nested-PCR as a malaria diagnostic tool is excellent with respect to its high accuracy, sensitivity, specificity, and ability to discriminate Plasmodium species. The sensitivity and specificity of nested-PCR compared with the microscopic method for detection of Plasmodium falciparum, Plasmodium vivax, and P. falciparum/P. vivax mixed infection were 71.4 vs 100%, 100 vs 98.7%, and 100 vs 95.0%, respectively. The sensitivity and specificity of the ELISA-based NovaLisa test kit compared with the microscopic method for detection of Plasmodium genus were 89.0 vs 91.6%, respectively. NovaLisa test kit provided comparable diagnostic performance. Its relatively low cost, simplicity, and rapidity enables large scale field application.
FlowGo: An Educational Kit for Fluid Dynamics and Heat Transfer
NASA Astrophysics Data System (ADS)
Guri, Dominic; Portsmore, Merredith; Kemmerling, Erica
2015-11-01
The authors have designed and prototyped an educational toolkit that will help middle-school-aged students learn fundamental fluid mechanics and heat transfer concepts in a hands-on play environment. The kit allows kids to build arbitrary flow rigs to solve fluid mechanics and heat transfer challenge problems. Similar kits for other engineering fields, such as structural and electrical engineering, have resulted in pedagogical improvements, particularly in early engineering education, where visual demonstrations have a significant impact. Using the FlowGo kit, students will be able to conduct experiments and develop new design ideas to solve challenge problems such as building plant watering systems or modeling water and sewage reticulation. The toolkit consists of components such as tubes, junctions, and reservoirs that easily snap together via a modular, universal connector. Designed with the Massachusetts K-12 science standards in mind, this kit is intended to be affordable and suitable for classroom use. Results and user feedback from students conducting preliminary tests of the kit will be presented.
Field demonstration of on-site analytical methods for TNT and RDX in ground water
DOE Office of Scientific and Technical Information (OSTI.GOV)
Craig, H.; Ferguson, G.; Markos, A.
1996-12-31
A field demonstration was conducted to assess the performance of eight commercially-available and emerging colorimetric, immunoassay, and biosensor on-site analytical methods for explosives 2,4,6-trinitrotoluene (TNT) and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) in ground water and leachate at the Umatilla Army Depot Activity, Hermiston, Oregon and US Naval Submarine Base, Bangor, Washington, Superfund sites. Ground water samples were analyzed by each of the on-site methods and results compared to laboratory analysis using high performance liquid chromatography (HPLC) with EPA SW-846 Method 8330. The commercial methods evaluated include the EnSys, Inc., TNT and RDX colorimetric test kits (EPA SW-846 Methods 8515 and 8510) with amore » solid phase extraction (SPE) step, the DTECH/EM Science TNT and RDX immunoassay test kits (EPA SW-846 Methods 4050 and 4051), and the Ohmicron TNT immunoassay test kit. The emerging methods tested include the antibody-based Naval Research Laboratory (NRL) Continuous Flow Immunosensor (CFI) for TNT and RDX, and the Fiber Optic Biosensor (FOB) for TNT. Accuracy of the on-site methods were evaluated using linear regression analysis and relative percent difference (RPD) comparison criteria. Over the range of conditions tested, the colorimetric methods for TNT and RDX showed the highest accuracy of the emerging methods for TNT and RDX. The colorimetric method was selected for routine ground water monitoring at the Umatilla site, and further field testing on the NRL CFI and FOB biosensors will continue at both Superfund sites.« less
An indigenously developed nitrite kit to aid in the diagnosis of urinary tract infection.
Sood, S; Upadhyaya, P; Kapil, A; Lodha, R; Jain, Y; Bagga, A
1999-09-01
To evaluate the utility of an indigenously developed nitrite kit for the rapid diagnosis of urinary tract infection (UTI) METHODS: 1018 urine specimens were collected from all cases where there was clinical suspicion of UTI. Samples were cultured as per standard microbiological protocol. Presence of nitrites was indicated by the development of purple color on addition of color developing solution and compared with the set of graded positive and negative controls also provided in the Kit. The results of the nitrite kit were compared with the semi-quantitative urine culture as the gold standard. The sensitivity, specificity, positive predictive and negative predictive values were 47%, 87%, 31% and 93%, respectively. Nitrite kit as a screening test can decrease the work load in the clinical bacteriology laboratory. More importantly in a field set up that is devoid of culture facilities, it can be used to correctly predict the absence of UTI.
ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT - ENVIROGARD PCB TEST KIT - STRATEGIC DIAGNOSTICS INC
In July 1997, the U.S. Environmental Protection Agency (EPA) conducted a demonstration of Polychlorinated biphenyl (PCB) field analytical techniques. The purpose of this demonstration was to evaluate field analytical technologies capable of detecting and quantifying PCBs in soil...
40 CFR 745.88 - Recognized test kits.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Recognized test kits. 745.88 Section... Renovation § 745.88 Recognized test kits. (a) Effective June 23, 2008, EPA recognizes the test kits that have... publicizes its recognition of the first test kit that meets both the negative response and positive response...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-19
... Partially-Exclusive Licensing of an Invention Concerning a Urinary Field Sampling Kit for the Determination.... Provisional Patent Application Serial No. 61/458,797, entitled ``Urinary Field Sampling Kit for the... INFORMATION: The invention relates to a urinary field sampling kit and method of its use for collecting and...
Le Dimna, M; Vrancken, R; Koenen, F; Bougeard, S; Mesplède, A; Hutet, E; Kuntz-Simon, G; Le Potier, M F
2008-01-01
Two real-time RT-PCR kits, developed by LSI (TaqVet CSF) and ADIAGENE (Adiavet CSF), obtained an agreement to be commercialised in France, subject to conditions, defined by the French Classical Swine Fever (CSF) National Reference Laboratory. The producers were asked to introduce an internal control to check the RNA extraction efficacy. The different criteria assessed were sensitivity, "pestivirus specificity", reproducibility and ease of handling, using 189 different samples. These samples were either CSFV inactivated strains or blood/serum/organs collected from CSFV experimentally infected pigs or naturally infected wild boars. The reproducibility of the assays was confirmed by the analysis of a batch-to-batch panel control that was used for inter-laboratory tests involving nine laboratories. The two kits were also tested for the use in mass diagnostics and the results proved the kits to be suited using pools of blood, serum and tonsils. Moreover, a field evaluation, carried out on spleen samples collected from the CSF surveillance of wild boars in an area known to be infected and from domestic pigs at a slaughterhouse, confirmed the high sensitivity and specificity of the two kits. This step-by-step evaluation procedure confirmed that the two commercial CSF real-time RT-PCR kits have a higher predictive value than the current diagnostic standard, Virus Isolation.
Buffer substitution in malaria rapid diagnostic tests causes false-positive results
2010-01-01
Background Malaria rapid diagnostic tests (RDTs) are kits that generally include 20 to 25 test strips or cassettes, but only a single buffer vial. In field settings, laboratory staff occasionally uses saline, distilled water (liquids for parenteral drugs dilution) or tap water as substitutes for the RDT kit's buffer to compensate for the loss of a diluent bottle. The present study assessed the effect of buffer substitution on the RDT results. Methods Twenty-seven RDT brands were run with EDTA-blood samples of five malaria-free subjects, who were negative for rheumatoid factor and antinuclear antibodies. Saline, distilled water and tap water were used as substitute liquids. RDTs were also run with distilled water, without adding blood. Results were compared to those obtained with the RDT kit's buffer and Plasmodium positive samples. Results Only eight cassettes (in four RDT brands) showed no control line and were considered invalid. Visible test lines occurred for at least one malaria-free sample and one of the substitutes in 20/27 (74%) RDT brands (saline: n = 16; distilled water: n = 17; and tap water: n = 20), and in 15 RDTs which were run with distilled water only. They occurred for all Plasmodium antigens and RDT formats (two-, three- and four-band RDTs). Clearance of the background of the strip was excellent except for saline. The aspects (colour, intensity and crispness) of the control and the false-positive test lines were similar to those obtained with the RDT kits' buffer and Plasmodium positive samples. Conclusion Replacement of the RDT kit's dedicated buffer by saline, distilled water and tap water can cause false-positive test results. PMID:20650003
NASA Astrophysics Data System (ADS)
Jakovels, Dainis; Saknite, Inga; Spigulis, Janis
2014-05-01
Laser speckle contrast analysis (LASCA) offers a non-contact, full-field, and real-time mapping of capillary blood flow and can be considered as an alternative method to Laser Doppler perfusion imaging. LASCA technique has been implemented in several commercial instruments. However, these systems are still too expensive and bulky to be widely available. Several optical techniques have found new implementations as connection kits for mobile phones thus offering low cost screening devices. In this work we demonstrate simple implementation of LASCA imaging technique as connection kit for mobile phone for primary low-cost assessment of skin blood flow. Stabilized 650 nm and 532 nm laser diode modules were used for LASCA illumination. Dual wavelength illumination could provide additional information about skin hemoglobin and oxygenation level. The proposed approach was tested for arterial occlusion and heat test. Besides, blood flow maps of injured and provoked skin were demonstrated.
Rieger, Toni; Kerber, Romy; El Halas, Hussein; Pallasch, Elisa; Duraffour, Sophie; Günther, Stephan; Ölschläger, Stephan
2016-01-01
Background. Diagnosis of Ebola virus (EBOV) disease (EVD) requires laboratory testing. Methods. The RealStar Filovirus Screen reverse transcription–polymerase chain reaction (RT-PCR) kit and the derived RealStar Zaire Ebolavirus RT-PCR kit were validated using in vitro transcripts, supernatant of infected cell cultures, and clinical specimens from patients with EVD. Results. The Filovirus Screen kit detected EBOV, Sudan virus, Taï Forest virus, Bundibugyo virus, Reston virus, and Marburg virus and differentiated between the genera Ebolavirus and Marburgvirus. The amount of filovirus RNA that could be detected with a probability of 95% ranged from 11 to 67 RNA copies/reaction on a LightCycler 480 II. The Zaire Ebolavirus kit is based on the Filovirus Screen kit but was optimized for detection of EBOV. It has an improved signal-to-noise ratio at low EBOV RNA concentrations and is somewhat more sensitive than the Filovirus kit. Both kits show significantly lower analytical sensitivity on a SmartCycler II. Clinical evaluation revealed that the SmartCycler II, compared with other real-time PCR platforms, decreases the clinical sensitivity of the Filovirus Screen kit to diagnose EVD at an early stage. Conclusions. The Filovirus Screen kit detects all human-pathogenic filoviruses with good analytical sensitivity if performed on an appropriate real-time PCR platform. High analytical sensitivity is important for early diagnosis of EVD. PMID:27549586
DEMONSTRATION BULLETIN: CLOR-N-SOIL PCB TEST KIT L2000 PCB/CHLORIDE ANALYZER - DEXSIL CORP.
DEXSIL CORP(Environmental Test Kits)The Dexsil Corporation (Dexsil) produces two test kits that detect polychlorinated biphenyls (PCB) in soil: the Dexsil Clor-N-Soil PCB Screening Kit, and the Dexsil L2000 PCB/Chloride Analyzer. The Dexsil Clor-N-Soil PCB Screening Kit extr...
HNU-HANBY PCP IMMUNOASSAY TEST KIT - INNOVATIVE TECHNOLOGY EVALUATION REPORT
The HNU-Hanby pentachlorophenol (PCP) test kit rapidly analyzes for PCP in soil samples. The test kit can only detect those PCP carriers that contain aromatic compounds. The test kit estimates PCP concentrations in soil samples indirectly by measuring petroleum hydrocarbon carrie...
Occurrence of ground waters of low hardness and of high chloride content in Lyon County, Minnesota
Rodis, Harry G.; Schneider, Robert
1960-01-01
Hardness and chloride determinations were made with field-testing kits at the time data were obtained on most of the farm wells in the county. Tests were made on wells that were reported to yield relatively soft or "salty" water.
Healthy Water Healthy People Field Monitoring Guide
ERIC Educational Resources Information Center
Project WET Foundation, 2003
2003-01-01
This 100-page manual serves as a technical reference for the "Healthy Water, Healthy People Water Quality Educators Guide" and the "Healthy Water Healthy People Testing Kits". Yielding in-depth information about ten water quality parameters, it answers questions about water quality testing using technical overviews, data interpretation guidelines,…
DEMONSTRATION BULLETIN: HNU-HANBY PCP IMMUNOASSAY TEST KIT - HNU - SYSTEMS, INC.
The HNU-Hanby test kit rapidly analyzes for petroleum hydrocarbons in soil and water samples. The test kit can be used to estimate pentachlorophenol (PCP) concentrations in samples when the carrier solvent is a petroleum hydrocarbon. The test kit estimates PCP concentrations in ...
40 CFR 745.88 - Recognized test kits.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Recognized test kits. 745.88 Section... Renovation § 745.88 Recognized test kits. (a) Effective June 23, 2008, EPA recognizes the test kits that have been determined by National Institute of Standards and Technology research to meet the negative...
40 CFR 745.88 - Recognized test kits.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Recognized test kits. 745.88 Section... Renovation § 745.88 Recognized test kits. (a) Effective June 23, 2008, EPA recognizes the test kits that have been determined by National Institute of Standards and Technology research to meet the negative...
40 CFR 745.88 - Recognized test kits.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Recognized test kits. 745.88 Section... Renovation § 745.88 Recognized test kits. (a) Effective June 23, 2008, EPA recognizes the test kits that have been determined by National Institute of Standards and Technology research to meet the negative...
40 CFR 745.88 - Recognized test kits.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Recognized test kits. 745.88 Section... Renovation § 745.88 Recognized test kits. (a) Effective June 23, 2008, EPA recognizes the test kits that have been determined by National Institute of Standards and Technology research to meet the negative...
Scientific evaluation of an intra-curricular educational kit to foster inquiry-based learning (IBL)
NASA Astrophysics Data System (ADS)
Debaes, Nathalie; Cords, Nina; Prasad, Amrita; Fischer, Robert; Euler, Manfred; Thienpont, Hugo
2014-07-01
Society becomes increasingly dependent on photonics technologies; however there is an alarming lack of technological awareness among secondary school students. They associate photonics with experiments and components in the class room that seem to bear little relevance to their daily life. The Rocard Report [5] highlights the need for fostering students' scientific skills and technological awareness and identifies inquiry based learning (IBL) as a means to achieve this. Students need to actively do science rather than be silent spectators. The `Photonics Explorer' kit was developed as an EU funded project to equip teachers, free-of-charge, with educational material designed to excite, engage and educate European secondary school students using guided inquiry based learning techniques. Students put together their own experiments using up-to-date versatile components, critically interpret results and relate the conclusions to relevant applications in their daily life. They work hands-on with the material, thus developing and honing their scientific and analytical skills that are otherwise latent in a typical class room situation. A qualitative and quantitative study of the impact of the kit in the classroom was undertaken with 50 kits tested in 7 EU countries with over 1500 students in the local language. This paper reports on the results of the EU wide field tests that show the positive impact of the kit in raising the self-efficacy, scientific skills and interest in science among students and the effectiveness of the kit in implementing IBL strategies in classrooms across EU.
LAMP kit for diagnosis of non-falciparum malaria in Plasmodium ovale infected patients.
Cuadros, Juan; Martin Ramírez, Alexandra; González, Iveth J; Ding, Xavier C; Perez Tanoira, Ramon; Rojo-Marcos, Gerardo; Gómez-Herruz, Peña; Rubio, Jose Miguel
2017-01-07
Microscopy and rapid diagnosis tests have a limited sensitivity in diagnosis of malaria by Plasmodium ovale. The LAMP kit (LoopAMP®) can be used in the field without special equipment and could have an important role in malaria control programmes in endemic areas and for malaria diagnosis in returned travellers. The performance of the Pan primer of the kit in detecting malaria by P. ovale was compared with the results of standard nPCR in samples of patients returning from P. ovale endemic areas. Plasmodium ovale positive samples (29, tested by PCR and/or microscopy) and malaria negative specimens (398, tested by microscopy and PCR) were collected in different hospitals of Europe from June 2014 to March 2016 and frozen at -20 °C. Boil and spin method was used to extract DNA from all samples and amplification was performed with LoopAMP® MALARIA kit (Eiken Chemical, Japan) in an automated turbidimeter (Eiken 500). The results of LAMP read by turbidimetry and with the naked eye were compared. The kit showed a sensitivity of 100% and a specificity of 97.24% with positive and negative predictive values of 72.5 and 100%, respectively. Naked eyed readings were in accordance with turbidimetry readings (sensitivity, 92.5%, specificity, 98.96% and positive and negative predictive values, respectively, 90.24 and 99.22%). The limit of detection of LAMP assay for P. ovale was between 0.8 and 2 parasites/µl. The Pan primer of the Malaria kit LoopAMP® can detect P. ovale at very low-levels and showed a predictive negative value of 100%. This tool can be useful in malaria control and elimination programmes and in returned travellers from P. ovale endemic areas. Naked eye readings are equivalent to automated turbidimeter readings in specimens obtained with EDTA.
USDA-ARS?s Scientific Manuscript database
We report the development of an affordable detection kit for the detection of ‘Candidatus Liberibacter asiaticus’ (Las) from the psyllid vector, Diaphorina citri, which can provide real time test results in the field or field laboratory within 30-40 minutes without the need for expensive laboratory ...
Statistical modeling of dental unit water bacterial test kit performance.
Cohen, Mark E; Harte, Jennifer A; Stone, Mark E; O'Connor, Karen H; Coen, Michael L; Cullum, Malford E
2007-01-01
While it is important to monitor dental water quality, it is unclear whether in-office test kits provide bacterial counts comparable to the gold standard method (R2A). Studies were conducted on specimens with known bacterial concentrations, and from dental units, to evaluate test kit accuracy across a range of bacterial types and loads. Colony forming units (CFU) were counted for samples from each source, using R2A and two types of test kits, and conformity to Poisson distribution expectations was evaluated. Poisson regression was used to test for effects of source and device, and to estimate rate ratios for kits relative to R2A. For all devices, distributions were Poisson for low CFU/mL when only beige-pigmented bacteria were considered. For higher counts, R2A remained Poisson, but kits exhibited over-dispersion. Both kits undercounted relative to R2A, but the degree of undercounting was reasonably stable. Kits did not grow pink-pigmented bacteria from dental-unit water identified as Methylobacterium rhodesianum. Only one of the test kits provided results with adequate reliability at higher bacterial concentrations. Undercount bias could be estimated for this device and used to adjust test kit results. Insensitivity to methylobacteria spp. is problematic.
Impact on arsenic exposure of a growing proportion of untested wells in Bangladesh
2012-01-01
Background In many areas of Bangladesh, it has been more than six years since a national campaign to test tubewells for arsenic (As) was conducted. Many households therefore draw their water for drinking and cooking from untested wells. Methods A household drinking water survey of 6646 households was conducted in Singair upazilla of Bangladesh. A subset of 795 untested wells used by 1000 randomly selected households was tested in the field by trained village workers with the Hach EZ kit, using an extended reaction time of 40 min, and in the laboratory by high-resolution inductively-coupled plasma-mass spectrometry (HR ICP-MS). Results The household survey shows that more than 80% of the wells installed since the national testing campaign in this area were untested. Less than 13% of the households with untested wells knew where a low-As well was located near their home. Village workers using the Hach EZ kit underestimated the As content of only 4 out of 795 wells relative to the Bangladesh standard. However, the As content of 168 wells was overestimated relative to the same threshold. Conclusion There is a growing need for testing tubewells in areas of Bangladesh where As concentrations in groundwater are elevated. This could be achieved by village workers trained to use a reliable field kit. Such an effort would result in a considerable drop in As exposure as it increases the opportunities for well switching by households. PMID:22353180
Reliability of M256 Chemical Agent Detector Kit at Extreme Environmental Temperatures
1988-02-01
therefore not discussed. 4 In a study conducted at Yuma Proving Ground (Ref. 3), 1256 Kits were sub- jected to a iO-day field-cdrry test; the samplers were... Proving Ground , Dugway, Utah, June 197-. 5. Zylstra, ).R. Letter Report of Cold Regions Piiase of DT 11 (Environmental ) and Agent Ci"a- Tf6- -Mib5...Dugway Proving Ground , ATTN: STEDP-SD-TA, Dugway, UT 84022-5000. ECBC memo dtd 14 Oct 2014 AD _ _ _ _ _ _ RDTA PROJECT NO. I-M-466710DO49 TECOM PROJT NO. 8
Home Pregnancy Test Kits: How Readable Are the Instructions?
ERIC Educational Resources Information Center
Holcomb, Carol Ann
At the conclusion of their study on home pregnancy test kits, Valinas and Perlman (1982) suggested that the instructions accompanying the kits be revised to make them easier to read. A study was undertaken to determine the readability of the printed instructions accompanying five home pregnancy test kits (Daisy II, Answer, Acu-Test, Predictor, and…
Mobile chemical detector (AP2C+SP4E) as an aid for medical decision making in the battlefield.
Eisenkraft, Arik; Markel, Gal; Simovich, Shirley; Layish, Ido; Hoffman, Azik; Finkelstein, Arseny; Rotman, Eran; Dushnitsky, Tsvika; Krivoy, Amir
2007-09-01
The combination of the AP2C unit with the SP4E kit composes a lightweight mobile detector of chemical warfare agents (CWA), such as nerve and mustard agents, with both vapor- and liquid-sampling capabilities. This apparatus was recently introduced into our military medical units as an aid for detection of CWA on casualties. Importantly, critical information regarding the applicability in the battlefield was absent. In view of the serious consequences that might follow a proclamation of CWA recognition in battlefield, a high false-positive rate positions the utilization of this apparatus as a medical decision tool in question. We have therefore conducted a field experiment to test the false-positive rate as well as analyze possible factors leading to false-positive readings with this device. The experiment was carried out before and after a 4-day army field exercise, using a standard AP2C device, a SP4E surface sampling kit, and a specially designed medical sampling kit for casualties, intended for medical teams. Soldiers were examined at rest, after mild exercise, and after 4 days in the field. The readings with AP2C alone were compared to the combination of AP2C and SP4E and to the medical sampling kit. Various body fluids served as negative controls. Remarkably, we found a false-positive rate of 57% at rest and after mild exercise, and an even higher rate of 64% after the 4-day field exercise with the AP2C detector alone, as compared to almost no false-positive readings with the combination of AP2C and SP4E. Strikingly, the medical sampling kit has yielded numerous false-positive readings, even in normal body fluids such as blood, urine, and saliva. We therefore see no place for using the medical sampling kit due to an unaccepted high rate of false-positive readings. Finally, we have designed an algorithm that uses the entire apparatus of AP2C and SP4E as a reliable validation tool for medical triage in the setting of exposure to nerve agents in the battlefield.
Comparison of presumptive blood test kits including hexagon OBTI.
Johnston, Emma; Ames, Carole E; Dagnall, Kathryn E; Foster, John; Daniel, Barbara E
2008-05-01
Four presumptive blood tests, Hexagon OBTI, Hemastix(R), Leucomalachite green (LMG), and Kastle-Meyer (KM) were compared for their sensitivity in the identification of dried bloodstains. Stains of varying blood dilutions were subjected to each presumptive test and the results compared. The Hexagon OBTI buffer volume was also reduced to ascertain whether this increased the sensitivity of the kit. The study found that Hemastix(R) was the most sensitive test for trace blood detection. Only with the reduced buffer volume was the Hexagon OBTI kit as sensitive as the LMG and KM tests. However, the Hexagon OBTI kit has the advantage of being a primate specific blood detection kit. This study also investigated whether the OBTI buffer within the kit could be utilized for DNA profiling after presumptive testing. The results show that DNA profiles can be obtained from the Hexagon OBTI kit buffer directly.
Bremner-Harrison, Samantha; Cypher, Brian L; Van Horn Job, Christine; Harrison, Stephen W R
2018-01-01
Utilisation of animal personality has potential benefit for conservation management. Due to logistics of robust behavioural evaluation in situ, the majority of studies on wild animals involve taking animals into captivity for testing, potentially compromising results. Three in situ tests for evaluation of boldness in San Joaquin kit fox ( Vulpes macrotis mutica ) were developed (ENOT: extended novel object test; RNOT: rapid novel object test; TH: trap/handling test). Each test successfully identified variation in boldness within its target age class(es). The TH test was suitable for use across all age classes. Tests were assessed for in situ suitability and for quantity/quality of data yielded. ENOT was rated as requiring high levels of time, cost and labour with greater likelihood of failure. However, it was rated highly for data quantity/quality. The TH test was rated as requiring little time, labour and cost, but yielding lower quality data. RNOT was rated in the middle. Each test had merit and could be adapted to suit project or species constraints. We recommend field-based evaluation of personality, reducing removal of animals from the wild and facilitating routine incorporation of personality assessment into conservation projects.
Wong, Li Ping; Atefi, Narges; AbuBakar, Sazaly
2016-08-12
As there is no specific treatment for dengue, early detection and access to proper treatment may lower dengue fatality. Therefore, having new techniques for the early detection of dengue fever, such as the use of dengue test kit, is vitally important. The aims of the study were: 1) identify factors associated with acceptance of a home self-test kit for dengue fever if the dengue test is available to the public and 2) find out the characteristics of the test kits that influence the use of the dengue test kit. A national telephone survey was carried out with 2,512 individuals of the Malaysian public aged 18-60 years old. Individuals were contacted by random digit dialling covering the whole of Malaysia from February 2012 to June 2013. From 2,512 participants, 6.1 % reported to have heard of the availability of the dengue home test kit and of these, 44.8 % expressed their intention to use the test kit if it was available. Multivariate logistic regressions indicated that participants with primary (OR: 0.65; 95 % CI: 0.43-0.89; p = 0.02, vs. tertiary educational level) and secondary educational levels (OR: 0.73; 95 % CI: 0.57-0.90; p = 0.01, vs. tertiary educational level) were less likely than participants with a tertiary educational level to use a home self-testing dengue kit for dengue if the kit was available. Participants with lower perceived barriers to dengue prevention (level of barriers 0-5) were less likely (OR: 0.67, 95 % CI: 0.53-0.85, p < 0.001, vs. higher perceived barriers) to use a home self-testing dengue kit for dengue if the kit was available compared to those with higher perceived barriers to dengue prevention (level of barriers 6-10). Participants with a lower total dengue fever knowledge score (range 0-22) were also less likely to use a home self-testing dengue kit for dengue if the kit was available (OR: 0.75; 95 % CI: 0.61-0.91, p = 0.001, vs. higher total dengue fever knowledge score) compared to those with a higher total dengue fever knowledge score (range 23-44). With response to characteristics of the test kit, participants indicated that ease of usability and easy to understand instructions were the most important factors influencing the decision to use the dengue home test kit; this was followed by the price of the test kit. The study highlights the need for provision of information to increase knowledge about the home self-testing dengue kit. Educational interventions should target people with low educational levels, those with lower dengue fever knowledge and those with lower perceived barriers to dengue prevention.
High Performance Computing Modernization Program Kerberos Throughput Test Report
2017-10-26
functionality as Kerberos plugins. The pre -release production kit was used in these tests to compare against the current release kit. YubiKey support...HPCMP Kerberos Throughput Test Report 3 2. THROUGHPUT TESTING 2.1 Testing Components Throughput testing was done to determine the benefits of the pre ...both the current release kit and the pre -release production kit for a total of 378 individual tests in order to note any improvements. Based on work
CHOL-N-SOIL PCB TEST KIT, DEXSIL CORP. - INNOVATIVE TECHNOLOGY Evaluation REPORT
This innovative technology evaluation report (ITER) presents the evaluation of two field screening technologies for determining polychlorinated biphenyl (PCB) contamination in soil. The demonstration was conducted by PRC Environmental Management, Inc. (PRC), under contract to the...
DEVELOPMENT OF AN IDENTIFICATION KIT FOR SPILLED HAZARDOUS MATERIALS
The Chemical Systems Laboratory (CSL) has developed a field kit to identify spilled hazardous materials in inland waters and on the ground. The Hazardous Materials Spills Identification Kit is a two-component kit consisting of an inverter/shortwave UV lamp unit for photochemical ...
Klaus, Christine; Beer, Martin; Saier, Regine; Schubert, Harald; Bischoff, Sabine; Süss, Jochen
2011-01-01
Tick-borne encephalitis (TBE) in animals is not well understood yet. TBE virus (TBEV) serology in several host species could be valuable for epidemiological analyses in the field as well as for the detection of clinical cases. However, performance and suitability of the available test systems are not well assessed. Therefore, we evaluated two commercial TBEV-ELISA kits in a pilot study and compared them for their suitability in veterinary applications. For this purpose, we tested 163 field collected goat sera and evaluated the results by serum neutralization test (SNT) as "gold standard". Twenty-eight SNT positive sera (17.2%) were detected. The best suited ELISA kit was used for determination of a species-specific cutoff for horses, cattle, sheep, goats, pigs, mice, dogs, rabbits and monkeys with defined sera from animals without known or with improbable contact to TBEV. The level of non-specific ELISA results does not only differ between animal species but may also be influenced by the age of the tested animals. The number of sera which tested false positive by ELISA was higher in older than in young sheep. In order to obtain defined polyclonal sera as references, two dogs, cattle, goats, sheep, rabbits and pigs each, as well as one horse and 90 mice were immunized four times with a commercially available TBEV vaccine. In conclusion, our results demonstrated that commercial TBEV-ELISA kits are suitable for application in veterinary medicine for both, verification of clinical TBE cases and epidemiological screening. However, positive ELISA results should be verified by SNT. Only a very low number of false negative ELISA-results were found.
Test/QA Plan for Verification of Microcystin Test Kits
Microcystin test kits are used to quantitatively measure total microcystin in recreational waters. These test kits are based on enzyme-linked immunosorbent assays (ELISA) with antibodies that bind specifically to microcystins or phosphate activity inhibition where the phosphatas...
Field determination of PCB in transformer oil. Volume 2. Clor-N-Oil PCB screening test. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fisher, D.J.; Rouse, T.O.; Lynn, T.
1984-10-01
The requirements for handling and disposing of transformer minerals oils containing more than 50 ppM PCB are, by federal regulation, different from those for oils containing lower concentrations. A rapid and simple test to distinguish between samples containing more than or less than this concentration would simplify proper control of transformer oils. This report describes the development of a small disposable test kit that can be used on-site to screen the chlorine content of transformer oils. The kit consists of two soft plastic tubes in which thin walled glass ampules containing premeasured amounts of reagents are broken. The reaction sequencemore » in the kits converts the chlorine in PCB to chloride ion. The color of the liquid in the kit after the last step is blue to purple if the chloride content due to the initial chlorine concentration of the oil is less than 20 ppM. If the chlorine content of the oil is below 20 ppM, the PCB content must be below 50 ppM. The liquid is colorless if the chlorine content is greater than 20 ppM. In this latter case, it is necessary to determine by gas chromatography whether the PCB content is actually greater than 50 ppM or if there is some other source of chlorine in the oil.« less
Training Educators to Teach the Sun and Space Weather Using a Kit of Tools
NASA Astrophysics Data System (ADS)
Keesee, A. M.; Ensign, T.
2014-12-01
NASA provides a wealth of data from Heliospheric missions to the public, but educators face several challenges to using such data in the classroom. These include the knowledge of what is available and how to use it, a full understanding of the science concepts the data demonstrate, ability to obtain and maintain products to access data, and access to technology (such as computer labs) for anything other than testing. To surmount these challenges, the Educator Resource Center at the NASA Independent Validation and Verification (IV&V) Center in Fairmont, WV has developed an operational model that focuses on housing, maintaining, and lending out kits of necessary equipment along with training educators in the science concepts and use of kit materials. Following this model, we have developed a Sun and Space Weather kit and an educator professional development course that we have presented several times. The kit includes a classroom set of iPads utilized to access data from NASA missions and other sources as well as create video reports for project based outcomes, a set of telescopes for safe solar viewing, and materials to explore magnetic fields and the electromagnetic spectrum. We will present an overview of the training course, the kit materials, and lessons learned.
21 CFR 610.44 - Use of reference panels by manufacturers of test kits.
Code of Federal Regulations, 2012 CFR
2012-04-01
... kits. 610.44 Section 610.44 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... Disease Agents § 610.44 Use of reference panels by manufacturers of test kits. (a) When available and appropriate to verify acceptable sensitivity and specificity, you, a manufacturer of test kits, must use a...
21 CFR 610.44 - Use of reference panels by manufacturers of test kits.
Code of Federal Regulations, 2014 CFR
2014-04-01
... kits. 610.44 Section 610.44 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... Disease Agents § 610.44 Use of reference panels by manufacturers of test kits. (a) When available and appropriate to verify acceptable sensitivity and specificity, you, a manufacturer of test kits, must use a...
21 CFR 610.44 - Use of reference panels by manufacturers of test kits.
Code of Federal Regulations, 2013 CFR
2013-04-01
... kits. 610.44 Section 610.44 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... Disease Agents § 610.44 Use of reference panels by manufacturers of test kits. (a) When available and appropriate to verify acceptable sensitivity and specificity, you, a manufacturer of test kits, must use a...
21 CFR 610.44 - Use of reference panels by manufacturers of test kits.
Code of Federal Regulations, 2011 CFR
2011-04-01
... kits. 610.44 Section 610.44 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... Disease Agents § 610.44 Use of reference panels by manufacturers of test kits. (a) When available and appropriate to verify acceptable sensitivity and specificity, you, a manufacturer of test kits, must use a...
21 CFR 610.44 - Use of reference panels by manufacturers of test kits.
Code of Federal Regulations, 2010 CFR
2010-04-01
... kits. 610.44 Section 610.44 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... Disease Agents § 610.44 Use of reference panels by manufacturers of test kits. (a) When available and appropriate to verify acceptable sensitivity and specificity, you, a manufacturer of test kits, must use a...
TEST KIT FOR FIELD EVALUATION OF THE CHEMICAL RESISTANCE OF PROTECTIVE CLOTHING
Personnel involved in emergency response and hazardous waste site activities often have the need to reach on-scene decisions regarding the effectiveness and limitations of chemical protective clothing. Three gravimetric techniques were evaluated as means for providing essential i...
Combating Terrorism: 2005 TSWG Review
2005-01-01
will have a greater capacity and will be more compact than existing kits. Advanced Hybrid Chemical Detection System Existing sensor systems to...detect chemical agents are either very expensive or provide limited sensitivity and response. Avir, LLC designed and built a hybrid detection system for... hybrid system at an equally low cost. The system has undergone live-agent testing and environmental testing. Extended field-testing in select buildings
Ricca, Alexandra V; Hall, Eric W; Khosropour, Christine M; Sullivan, Patrick S
2016-11-01
In the United States, men who have sex with men (MSM) are known to disproportionately have HIV. The authors sought to describe the acceptability of providing at-home dried blood spot specimen collection kits for HIV testing among MSM. Between August 2010 and December 2010, the authors recruited Internet-using, HIV-negative or -unknown MSM to participate in a 12-month study of behavioral risks. Eligible participants were mailed an at-home HIV test. Of the 896 men who were sent a test kit, 735 (82%) returned the kit. Returning a test kit was significantly associated with race (P = .002), highest level of education (P = .012), and annual income (P = .026). The adjusted odds of black, non-Hispanic men returning a test kit were about half of the odds of white, non-Hispanic men returning a test kit (adjusted odds ratios: 0.49; 95% confidence intervals: 0.31-0.78). Men who have sex with men are willing to provide biological specimens as part of an Internet-based HIV prevention study. © The Author(s) 2016.
Kandhakumari, Gandhi; Stephen, Selvaraj
2017-01-01
At present, three rapid kits are available globally for the confirmation of Mycobacterium tuberculosis complex (MTBC) in cultures by MPT64 antigen (MPT64 Ag) detection. These include Capilia TB, SD Bioline, and BD MGIT TBc Identification (TBcID). The third kit is yet to be validated in India. We have tested this kit and compared with SD Bioline using conventional tests as gold standard. Seventy-one MTBC (70 M. tuberculosis and one Mycobacterium bovis) and four nontuberculous mycobacteria (NTM) were isolated from 649 clinical specimens in MGIT 960 and/or Lowenstein-Jensen slants (LJ). MPT64 Ag was detected by both TBcID and SD Bioline kits in all the 71 clinical isolates and the reference strain M. tuberculosis H37Rv. All NTM species tested were negative by the two different kits. Thus, TBcID kit showed 100% concordance in terms of sensitivity and specificity. Rapid kits confirm MTBC cultures within 15 min in contrast to several weeks' time required by conventional techniques.
Evaluation of a rapid immunodiagnostic test kit for rabies virus.
Kang, BoKyu; Oh, JinSik; Lee, ChulSeung; Park, Bong-Kyun; Park, YoungNam; Hong, KyungSoo; Lee, KyungGi; Cho, ByungKi; Song, DaeSub
2007-10-01
A rapid immunodiagnostic test kit for rabies virus detection was evaluated using 51 clinical samples and 4 isolates of rabies virus. The quick detection of rabies virus under field conditions may be helpful in determining if post-exposure prophylaxis is needed, thereby avoiding unnecessary treatments, as well as undue economic burden. There are several widely used diagnostic methods for rabies, including fluorescent antibody tests, reverse transcription polymerase chain reaction, and electron microscopy; however, these methods include time-consuming, intricate, and costly procedures. The rapid immunodiagnostic test was able to detect rabies virus in clinical samples, including brain tissue and saliva, in addition to 10(3.2) 50% lethal dose (LD(50))/mL cell-adapted rabies virus. The assay was not cross-reactive with non-rabies virus microbes. When the performance of the rapid immunodiagnostic test was compared to a fluorescent antibody test, the rapid immunodiagnostic test had a sensitivity of 91.7% and specificity of 100% (95.8% CI).
A look at the purchase and use of home pregnancy-test kits.
Coons, S J
1989-04-01
A study was conducted to obtain information regarding the purchase and use of home pregnancy-test kits. Questionnaires were distributed to 438 women entering a family-planning clinic in the fall of 1987. A total of 153 questionnaires were completed and returned, providing a response rate of 34.9%. Results indicated that nearly 40% of the respondents had used a home pregnancy-test kit at least once. Of those who had used a home pregnancy-test kit, the majority did so because of "the speed of obtaining results" or "convenience." Although nearly 87% of the pregnancy-test kits had been purchased in a pharmacy, pharmacists played only a minor role in the decision-making process concerning purchase and use. Some three-fourths of the subjects listed "information on the side of the package," "price," or "advertisements" as the most important factor in the selection of a specific brand of test kit. Only about 7% of the subjects selected "recommendation of the pharmacist" as the most important factor. The results suggest that pharmacists could be doing more to promote the appropriate use of self-testing products, specifically home pregnancy-test kits.
Martin, Laura; Coronel, Jorge; Faulx, Dunia; Valdez, Melissa; Metzler, Mutsumi; Crudder, Chris; Castillo, Edith; Caviedes, Luz; Grandjean, Louis; Rodriguez, Mitzi; Friedland, Jon S.; Gilman, Robert H.; Moore, David A. J.
2014-01-01
Background Even though the WHO-endorsed, non-commercial MODS assay offers rapid, reliable TB liquid culture and phenotypic drug susceptibility testing (DST) at lower cost than any other diagnostic, uptake has been patchy. In part this reflects misperceptions about in-house assay quality assurance, but user convenience of one-stop procurement is also important. A commercial MODS kit was developed by Hardy Diagnostics (Santa Maria, CA, USA) with PATH (Seattle, WA, USA) to facilitate procurement, simplify procedures through readymade media, and enhance safety with a sealing silicone plate lid. Here we report the results from a large-scale field evaluation of the MODS kit in a government service laboratory. Methods & Findings 2446 sputum samples were cultured in parallel in Lowenstein-Jensen (LJ), conventional MODS and in the MODS kit. MODS kit DST was compared with conventional MODS (direct) DST and proportion method (indirect) DST. 778 samples (31.8%) were Mycobacterium tuberculosis culture-positive. Compared to conventional MODS the sensitivity, specificity, positive, and negative predictive values (95% confidence intervals) of the MODS Kit were 99.3% (98.3–99.8%), 98.3% (97.5–98.8%), 95.8% (94.0–97.1%), and 99.7% (99.3–99.9%). Median (interquartile ranges) time to culture-positivity (and rifampicin and isoniazid DST) was 10 (9–13) days for conventional MODS and 8.5 (7–11) for MODS Kit (p<0.01). Direct rifampicin and isoniazid DST in MODS kit was almost universally concordant with conventional MODS (97.9% agreement, 665/679 evaluable samples) and reference indirect DST (97.9% agreement, 687/702 evaluable samples). Conclusions MODS kit delivers performance indistinguishable from conventional MODS and offers a convenient, affordable alternative with enhanced safety from the sealing silicone lid. The availability in the marketplace of this platform, which conforms to European standards (CE-marked), readily repurposed for second-line DST in the near future, provides a fresh opportunity for improving equity of access to TB diagnosis and first and second-line DST in settings where the need is greatest. PMID:25225802
Martin, Laura; Coronel, Jorge; Faulx, Dunia; Valdez, Melissa; Metzler, Mutsumi; Crudder, Chris; Castillo, Edith; Caviedes, Luz; Grandjean, Louis; Rodriguez, Mitzi; Friedland, Jon S; Gilman, Robert H; Moore, David A J
2014-01-01
Even though the WHO-endorsed, non-commercial MODS assay offers rapid, reliable TB liquid culture and phenotypic drug susceptibility testing (DST) at lower cost than any other diagnostic, uptake has been patchy. In part this reflects misperceptions about in-house assay quality assurance, but user convenience of one-stop procurement is also important. A commercial MODS kit was developed by Hardy Diagnostics (Santa Maria, CA, USA) with PATH (Seattle, WA, USA) to facilitate procurement, simplify procedures through readymade media, and enhance safety with a sealing silicone plate lid. Here we report the results from a large-scale field evaluation of the MODS kit in a government service laboratory. 2446 sputum samples were cultured in parallel in Lowenstein-Jensen (LJ), conventional MODS and in the MODS kit. MODS kit DST was compared with conventional MODS (direct) DST and proportion method (indirect) DST. 778 samples (31.8%) were Mycobacterium tuberculosis culture-positive. Compared to conventional MODS the sensitivity, specificity, positive, and negative predictive values (95% confidence intervals) of the MODS Kit were 99.3% (98.3-99.8%), 98.3% (97.5-98.8%), 95.8% (94.0-97.1%), and 99.7% (99.3-99.9%). Median (interquartile ranges) time to culture-positivity (and rifampicin and isoniazid DST) was 10 (9-13) days for conventional MODS and 8.5 (7-11) for MODS Kit (p<0.01). Direct rifampicin and isoniazid DST in MODS kit was almost universally concordant with conventional MODS (97.9% agreement, 665/679 evaluable samples) and reference indirect DST (97.9% agreement, 687/702 evaluable samples). MODS kit delivers performance indistinguishable from conventional MODS and offers a convenient, affordable alternative with enhanced safety from the sealing silicone lid. The availability in the marketplace of this platform, which conforms to European standards (CE-marked), readily repurposed for second-line DST in the near future, provides a fresh opportunity for improving equity of access to TB diagnosis and first and second-line DST in settings where the need is greatest.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-15
... kit) \\5\\ 17.50 (v) NIR or NMR Analysis (protein, oil, starch, etc.) 2.40 (vi) Waxy corn (per test) 2...) (d) All other Mycotoxins (rapid test kit 38.50 method-applicant provides kit) \\3\\ (e) NIR or NMR... kit) \\3\\ (e) NIR or NMR Analysis (protein, oil, starch, 18.60 etc.) (f) Sunflower oil (per test) 18.60...
Cyanide can be present in various forms in water. The cyanide test kit evaluated in this verification study (Industrial Test System, Inc. Cyanide Regent Strip ™ Test Kit) was designed to detect free cyanide in water. This is done by converting cyanide in water to cyanogen...
7 CFR 868.90 - Fees for certain Federal inspection services.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Laboratory Test Services 1 Laboratory tests Fees (1) Aflatoxin (Quantitative—HPLC) $182.00 (2) Aflatoxin (Quantitative—Test Kit) 87.00 (3) Aflatoxin (Qualitative—Test Kit) 47.00 (4) Appearance and odor 7.00 (5) Ash 17...) Vomitoxin (Quantitative—Test Kit) 81.00 (32) Other laboratory analytical services (per hour per service...
7 CFR 868.90 - Fees for certain Federal inspection services.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Laboratory Test Services 1 Laboratory tests Fees (1) Aflatoxin (Quantitative—HPLC) $182.00 (2) Aflatoxin (Quantitative—Test Kit) 87.00 (3) Aflatoxin (Qualitative—Test Kit) 47.00 (4) Appearance and odor 7.00 (5) Ash 17...) Vomitoxin (Quantitative—Test Kit) 81.00 (32) Other laboratory analytical services (per hour per service...
7 CFR 868.90 - Fees for certain Federal inspection services.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Laboratory Test Services 1 Laboratory tests Fees (1) Aflatoxin (Quantitative—HPLC) $182.00 (2) Aflatoxin (Quantitative—Test Kit) 87.00 (3) Aflatoxin (Qualitative—Test Kit) 47.00 (4) Appearance and odor 7.00 (5) Ash 17...) Vomitoxin (Quantitative—Test Kit) 81.00 (32) Other laboratory analytical services (per hour per service...
7 CFR 868.90 - Fees for certain Federal inspection services.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Laboratory Test Services 1 Laboratory tests Fees (1) Aflatoxin (Quantitative—HPLC) $182.00 (2) Aflatoxin (Quantitative—Test Kit) 87.00 (3) Aflatoxin (Qualitative—Test Kit) 47.00 (4) Appearance and odor 7.00 (5) Ash 17...) Vomitoxin (Quantitative—Test Kit) 81.00 (32) Other laboratory analytical services (per hour per service...
Basic Teaching Kit on Consumer Advertising.
ERIC Educational Resources Information Center
Proctor and Gamble Co., Cincinnati, OH.
This advertising kit was developed by Procter and Gamble in response to requests from teachers and consumer educators who asked for materials from business about business. The kit is not intended to cover the entire field of advertising. Rather, it centers on advertising as it is known and practiced by Procter and Gamble. The purpose of the kit is…
Immunoassay test kits are based on immunoassay methods, where specific antibodies are used to detect and measure the contaminants of interest. Immunoassay test kits rely on the reaction of a contaminant or antigen with a selective antibody to give a product that can be measures....
TQAP for Verification of Qualitative Lead Test Kits
There are lead-based paint test kits available to help home owners and contractors identify lead-based paint hazards before any Renovation, Repair, and Painting (RRP) activities take place so that proper health and safety meaures can be enacted. However, many of these test kits ...
Westman, Mark E; Malik, Richard; Hall, Evelyn; Sheehy, Paul A; Norris, Jacqueline M
2017-02-01
Feline leukaemia virus (FeLV) can be a challenging infection to diagnose due to a complex feline host-pathogen relationship and occasionally unreliable test results. This study compared the accuracy of three point-of-care (PoC) FeLV p27 antigen test kits commonly used in Australia and available commercially worldwide (SNAP FIV/FeLV Combo, Witness FeLV/FIV and Anigen Rapid FIV/FeLV), using detection of FeLV provirus by an in-house real-time polymerase chain reaction (qPCR) assay as the diagnostic gold standard. Blood (n=563) and saliva (n=419) specimens were collected from a population of cats determined to include 491 FeLV-uninfected and 72 FeLV-infected individuals (45 progressive infections [p27 and qPCR positive], 27 regressive infections [p27 negative, qPCR positive]). Sensitivity and specificity using whole blood was 63% and 94% for SNAP Combo, 57% and 98% for Witness, and 57% and 98% for Anigen Rapid, respectively. SNAP Combo had a significantly lower specificity using blood compared to the other two kits (P=0.004 compared to Witness, P=0.007 compared to Anigen Rapid). False-positive test results occurred with all three kits using blood, and although using any two kits in parallel increased specificity, no combination of kits completely eliminated the occurrence of false-positive results. We therefore recommend FeLV proviral PCR testing for any cat that tests positive with a PoC FeLV antigen kit, as well as for any cat that has been potentially exposed to FeLV but tests negative with a FeLV antigen kit, before final assignment of FeLV status can be made with confidence. For saliva testing, sensitivity and specificity was 54% and 100%, respectively, for all three test kits. The reduced sensitivity of saliva testing compared to blood testing, although not statistically significant, suggests saliva testing with the current generation of PoC FeLV antigen kits is unsuitable for screening large populations of cats, such as in shelters. Copyright © 2016 Elsevier Ltd. All rights reserved.
Keith, Matthew C L; Bolli, Roberto
2015-03-27
Although numerous preclinical investigations have consistently demonstrated salubrious effects of c-kit(pos) cardiac cells administered after myocardial infarction, the mechanism of action remains highly controversial. We and others have found little or no evidence that these cells differentiate into mature functional cardiomyocytes, suggesting paracrine effects. In this review, we propose a new paradigm predicated on a comprehensive analysis of the literature, including studies of cardiac development; we have (facetiously) dubbed this conceptual construct "string theory" of c-kit(pos) cardiac cells because it reconciles multifarious and sometimes apparently discrepant results. There is strong evidence that, during development, the c-kit receptor is expressed in different pools of cardiac progenitors (some capable of robust cardiomyogenesis and others with little or no contribution to myocytes). Accordingly, c-kit positivity, in itself, does not define the embryonic origins, lineage capabilities, or differentiation capacities of specific cardiac progenitors. C-kit(pos) cells derived from the first heart field exhibit cardiomyogenic potential during development, but these cells are likely depleted shortly before or after birth. The residual c-kit(pos) cells found in the adult heart are probably of proepicardial origin, possess a mesenchymal phenotype (resembling bone marrow mesenchymal stem/stromal cells), and are capable of contributing significantly only to nonmyocytic lineages (fibroblasts, smooth muscle cells, and endothelial cells). If these 2 populations (first heart field and proepicardium) express different levels of c-kit, the cardiomyogenic potential of first heart field progenitors might be reconciled with recent results of c-kit(pos) cell lineage tracing studies. The concept that c-kit expression in the adult heart identifies epicardium-derived, noncardiomyogenic precursors with a mesenchymal phenotype helps to explain the beneficial effects of c-kit(pos) cell administration to ischemically damaged hearts despite the observed paucity of cardiomyogenic differentiation of these cells. © 2015 American Heart Association, Inc.
Detection of illicit drugs in impaired driver saliva by a field-usable SERS analyzer
NASA Astrophysics Data System (ADS)
Shende, Chetan; Huang, Hermes; Farquharson, Stuart
2014-05-01
One of the greatest dangers of drug use is in combination with driving. According to the most recent National Highway Traffic Safety Administration (NHTSA) studies, more than 11% of drivers tested positive for illicit drugs, while 18% of drivers killed in accidents tested positive for illicit, prescription or over-the-counter drugs. Consequently, there is a need for a rapid, noninvasive, roadside drug testing device, similar to the breathalyzers used by law enforcement officials to estimate blood alcohol levels of impaired drivers. In an effort to satisfy this need we have been developing a sampling kit that allows extraction of drugs from 1 mL of saliva and detection by surfaceenhanced Raman spectroscopy using a portable Raman analyzer. Here we describe the development of the sampling kit and present measurements of diazepam at sub μg/mL concentrations measured in ~15 minutes.
Rastawicki, Waldemar; Rokosz, Natalia; Jagielski, Marek
2011-01-01
The Binax and the Biotest urinary antigen kits for detection of L. pneumophila antigen were compared by testing of selected 67 urine samples obtained from EWGLI as reference samples in External Quality Assessment Scheme. Thirty nine were positive with the Binax kit (100% of sensitivity), and 33 were positive with the Biotest (84.6% of sensitivity). The test specificities were 100% for the both kits. It was concluded that the Binax kit was more suitable for the routine diagnosis of Legionella infections than the Biotest kit.
Undeclared Formaldehyde Levels in Patient Consumer Products: Formaldehyde Test Kit Utility.
Ham, Jason E; Siegel, Paul; Maibach, Howard
2018-05-03
Formaldehyde allergic contact dermatitis (ACD) may be due to products with free formaldehyde or formaldehyde-releasing agents, however, assessment of formaldehyde levels in such products is infrequently conducted. The present study quantifies total releasable formaldehyde from "in-use" products associated with formaldehyde ACD and tests the utility of commercially available formaldehyde spot test kits. Personal care products from 2 patients with ACD to formaldehyde were initially screened at the clinic for formaldehyde using a formaldehyde spot test kit. Formaldehyde positive products were sent to the laboratory for confirmation by gas chromatography-mass spectrometry. In addition, 4 formaldehyde spot test kits were evaluated for potential utility in a clinical setting. Nine of the 10 formaldehyde spot test kit positive products obtained from formaldehyde allergic patients had formaldehyde with total releasable formaldehyde levels ranging from 5.4 to 269.4 µg/g. Of these, only 2 shampoos tested listed a formaldehyde-releasing agent in the ingredients or product literature. Subsequently, commercially available formaldehyde spot test kits were evaluated in the laboratory for ability to identify formaldehyde in personal care products. Chemical based formaldehyde spot test were more reliable than the enzymatic based test in identifying product releasable formaldehyde content. It is concluded that product labeled ingredient lists and available information are often inadequate to confirm the potential for formaldehyde exposure and chemical based spot test kits may have utility for identification of potential formaldehyde exposure from personal care products.
The purpose of this issue paper is to address the availability and performance characteristics of portable lead test kits especially suited for lead in paint, procedures for evaluating the performance of these test kits, and the availability of performance evaluation (PE) materia...
Solid phase microextraction field kit
Nunes, Peter J.; Andresen, Brian D.
2005-08-16
A field kit for the collection, isolation and concentration of trace amounts of high explosives (HE), biological weapons (BW) and chemical weapons (CW) residues in air, soil, vegetation, swipe, and liquid samples. The field kit includes a number of Solid Phase Microextraction (SPME) fiber and syringe assemblies in a hermetically sealed transportation container or tubes which includes a sampling port, a number of extra SPME fiber and syringe assemblies, the fiber and syringe assemblies including a protective cap for the fiber, and an extractor for the protective cap, along with other items including spare parts, protective glove, and an instruction manual, all located in an airtight container.
Young, Sean D; Daniels, Joseph; Chiu, ChingChe J; Bolan, Robert K; Flynn, Risa P; Kwok, Justin; Klausner, Jeffrey D
2014-01-01
Rates of unrecognized HIV infection are significantly higher among Latino and Black men who have sex with men (MSM). Policy makers have proposed that HIV self-testing kits and new methods for delivering self-testing could improve testing uptake among minority MSM. This study sought to conduct qualitative assessments with MSM of color to determine the acceptability of using electronic vending machines to dispense HIV self-testing kits. African American and Latino MSM were recruited using a participant pool from an existing HIV prevention trial on Facebook. If participants expressed interest in using a vending machine to receive an HIV self-testing kit, they were emailed a 4-digit personal identification number (PIN) code to retrieve the test from the machine. We followed up with those who had tested to assess their willingness to participate in an interview about their experience. Twelve kits were dispensed and 8 interviews were conducted. In general, participants expressed that the vending machine was an acceptable HIV test delivery method due to its novelty and convenience. Acceptability of this delivery model for HIV testing kits was closely associated with three main factors: credibility, confidentiality, and convenience. Future research is needed to address issues, such as user-induced errors and costs, before scaling up the dispensing method.
USDA-ARS?s Scientific Manuscript database
Three serologic methods for antibody detection in elephant tuberculosis (TB), multiantigen print immunoassay (MAPIA), ElephantTB STAT-PAK kit, and DPP VetTB test, were validated prospectively using serial serum samples from 14 captive elephants in 5 countries which were diagnosed with TB by positive...
... test (home test); Ovulation prediction test; Ovulation predictor kit; Urinary LH immunoassays; At-home ovulation prediction test; ... Ovulation prediction test kits most often come with five to seven sticks. You may need to test for several days to detect a ...
Development of a Portable Test Kit for Field-Screening Paints
1986-01-01
Use) rods. TT-P-002119 Paint, Latex Base, High Traffic Areas, Flat and Eggshell Finish Discussion (Low Lustre, For Interior Use) The applications...testing uniformity in different clean. Eggshell or flat surfaces have more pigment than laboratories. Although the methods are designed to vehicle on...samples (Table 12) were selected from the useful for determining the gloss of eggshell , semigloss, series to represent the range of gloss (glossy
A Portable Kit for Rapid Diagnosis of Infectious Diseases under Field Conditions
1980-08-14
INFECTIONS SHIGELLA TYPHOID FEVER STREPTOCOCCUS An example of a public health application for rapid diagnosis using the COAG test is provided by studies...than in infections in Fig. Principles of gel diffusion (GD) and of counter- monkeys with human parasites (BID%%IAL et al. 1973, immunoelectrophoresis...the cerebrospinal fluid and immunofluorescence tests for detection of malaria te ai preient ith croup inal fuidan antibodies in Aotus monkeys
Gaudin, V; Hedou, C; Rault, A; Sanders, P; Verdon, E
2009-04-01
The screening of antimicrobial residues in eggs is an especially important subject. Three different commercial kits for the screening of sulphonamides and other antimicrobials in eggs were validated in accordance with Decision 2002/657/EC: one enzyme-linked immunoabsorbant assay (ELISA) kit multi-sulphonamides (from RAISIO Diagnostics) and two microbiological tests (a Premi test from DSM and an Explorer kit from Zeu-Inmunotec). The false-positive rates were lower than 2% for all kits. The detection capabilities (CCbeta) have to be as low as possible for banned substances and lower than the maximum residue limit (MRL) when MRLs have been set. The sensitivity of the Premi test was better than that of the Explorer test, probably because of the dilution of the eggs before the Explorer test was used. The CCbeta values towards most of the tested sulphonamides were satisfactory with the Premi test (< or = 100 microg kg(-1)). Performance in a proficiency test for the detection of sulphonamides in eggs with the Premi test confirmed these results. The detection capabilities of tetracycline and doxycycline were at the level of the MRL or twice the MRL maximum. The detection capabilities for chlortetracycline and oxytetracycline were higher (four to six times the MRL). The detection capabilities for amoxicillin, neomycin, tylosin and erythromycin were lower than their respective MRLs. Detection capabilities for sulphonamides were much lower for the ELISA kit than for microbiological tests. The ELISA kit could be recommended for the targeted screening of sulphonamides in eggs. On the other hand, the Explorer and Premi tests could be used as wide screening tests allowing the detection of most of the antimicrobial families.
NASA Technical Reports Server (NTRS)
Stow, D. A.; Estes, J. E.; Mertz, F. C.
1981-01-01
A learning kit is an essential part of any remote sensing workshop, course, or in-house training program to provide the "hands-on" experience of working with remotely sensed imagery. This is the objective of laboratory and field exercises as well as the reason behind the production of imagery/map kits. The way in which these learning kits (containing conventional remotely sensed and collateral data products) are put together is described and some concerns that influence the creation of learning kits are discussed. These include budgetary constraints, number of imagery types, and number of collateral data types.
Diekman, Shane; Huitric, Michele; Netterville, Linda
2010-01-01
This article describes the development of the Fire H.E.L.P. tool kit for training selected Meals On Wheels (MOW) staff in Texas to implement a fire safety program for homebound older adults. We used a formative evaluation approach during the tool kit's development, testing, and initial implementation stages. The tool kit includes instructional curricula on how to implement Fire H.E.L.P., a home assessment tool to determine a residence's smoke alarm needs, and fire safety educational materials. During the tool kit's pilot test, MOW participants showed enhanced fire safety knowledge and high levels of confidence about applying their newfound training skills. After the pilot test, MOW staff used the tool kit to conduct local training sessions, provide fire safety education, and install smoke alarms in the homes of older adults. We believe the approach used to develop this tool kit can be applied to education efforts for other, related healthy home topics.
Evaluation of commercial ELISA kits for the detection of antibodies against bluetongue virus.
Niedbalski, W
2011-01-01
The aim of this study was to estimate the diagnostic value of different commercially available ELISA kits for the detection of bluetongue virus (BTV) antibodies in infected and vaccinated animals. The relative specificity of ELISA kits was evaluated using a panel of sera originating from healthy cattle, never vaccinated nor exposed to BTV. All ELISA kits applied had a high relative specificity (99.3 - 100%). The relative sensitivity of ELISA kits assessed using a panel of sera collected from BTV infected cattle was also high and similar for all the kits (97.3 - 100%). However, the relative sensitivity evaluated on the basis of testing vaccinated animals was different: the highest sensitivity was found for Ingenasa, PrioCHECK and ID VET ELISAs (96.5 - 98.3%). Slightly lower sensitivity was calculated for Pourquier and LSI kits (82.8% and 85.4%, respectively) and much lower sensitivity was found for VMRD ELISA kit (69.5%). The repeatability of BTV ELISA kits was expressed as a coefficient of variation (CV) of results of sera tested 5 times in the same day and in different days by the period of 2 months, by the same person, in the same conditions, and by using the same equipment. The CVs of sera tested in all ELISA kits ranged from 6.1 to 9.8% and were below 10% threshold adopted as a maximum for the acceptable repeatability of the method. In conclusion, it can be stated that the applied ELISA kits can be a valuable diagnostic tool for the serological monitoring studies in the BTV contaminated premises. All the methods are very specific and sensitive when testing BTV infected animals. Nevertheless, the Ingenasa and PrioCHECK can be the most useful in sero-surveillance of livestock following vaccination.
Métayé, Thierry; Rosenberg, Thierry; Guilhot, Joëlle; Bouin-Pineau, Marie-Hélène; Perdrisot, Rémy
2012-09-01
A high radiochemical purity (RCP) is recommended for radiopharmaceutical compounds used in the clinical practice of nuclear medicine. However, some preparations of (99m)Tc-sestamibi contain excess impurities (>6%). To understand the origin of these impurities, we investigated the effect of sodium nitrate on the RCP of sestamibi preparations by testing eluates from 3 commercially available (99m)Tc generators. The sestamibi kits (Stamicis) were reconstituted with (99m)Tc eluate from nitrate-containing wet-column (NCWC), nitrate-free wet-column (NFWC), and nitrate-free dry-column (NFDC) generators. Sodium nitrate was 0.05 mg/mL in eluates from the NCWC generators. The RCP was determined using aluminum oxide sheets as the stationary phase and absolute ethanol as the mobile phase. Succimer, tetrofosmin, oxidronate, exametazine, albumin nanocolloid, and soluble albumin were also tested for their RCP values with eluates from the 3 different (99m)Tc generators. The RCP assessment of (99m)Tc-sestamibi was performed on 127 Stamicis preparations. Significantly lower RCP values were found for Stamicis kits prepared with the NCWC generator than for Stamicis prepared with the NFWC (P < 0.0001) and NFDC (P < 0.0001) generators. The number of Stamicis preparations with an RCP under 94% was greater with the NCWC generator (32 of 53 kits) than with the NFDC (2 of 51 kits) or NFWC (0 of 23 kits) generator. Furthermore, the addition of a 0.05 mg/mL concentration of nitrate in NFWC generator eluates significantly decreased the RCP of the Stamicis preparation. In the absence of nitrate in (99m)Tc eluate, no difference was observed between the RCP values of Stamicis kits prepared with the NFWC and NFDC generators. The (99m)Tc impurities generated by nitrates did not modify the quality of myocardial imaging (normal heart-to-lung ratio, 2.2), probably because these impurities are not in the heart field of view. No other tested (99m)Tc-radiopharmaceutical interfered with nitrates. We recommend using nitrate-free generator eluates in (99m)Tc-sestamibi preparations to improve the product quality and prevent unnecessary exposure of the patient to radiation.
Greibe, Eva; Nexo, Ebba
2011-11-01
Active vitamin B12 absorption is followed by an increase in holotranscobalamin (holoTC) upon loading with a high physiological dose of the vitamin (the CobaSorb test). This study evaluates the use of a newly launched EIA kit for measurement of holoTC (active B12) in relation to the CobaSorb test. Intra-assay imprecision and linearity of the EIA kit was examined, employing serum pools of increasing holoTC concentrations. For the CobaSorb test, holoTC was measured before and after loading with 3-times 9 μg of vitamin B12 employing both the in-house ELISA and the EIA kit (n=25). The EIA kit showed an intra-assay CV between 2.2% and 5.8% for holoTC values ranging from 21 to 80 pmol/L. Employing diluted serum samples resulted in spurious high values of holoTC. The EIA kit performed well in relation to the CobaSorb test and classified the patients studied as capable of absorbing vitamin B12 (n=10) or not (n=15), as did the in-house ELISA. The Active B12 (holoTC) EIA kit proved suitable for use with the CobaSorb test, but not for analysis of diluted serum samples.
Pharmacists' views on and experiences with bowel cancer screening kits in Auckland, New Zealand.
Martini, Nataly; Basdew, Kamlika; Kammona, Ala; Shen, Amy; Taylor, Caragh; McIntosh, Timothy R; Barnes, Joanne
2014-08-01
To explore the views of New Zealand pharmacists on bowel cancer screening, particularly with regards to faecal occult blood testing (FOBT) kits, self-perceived knowledge on FOBT kits and barriers, motivators and experiences with selling and counselling consumers with respect to FOBT kits. Semi-structured interviews were conducted face to face or by telephone with 20 community pharmacists in the Auckland region. Interviews were recorded and transcribed verbatim and data were coded and analysed using NVivo software to identify key themes. Participant pharmacists believed that they were well placed to provide advice on FOBT kits to consumers. Barriers to selling the kits included cost and perceived lack of test sensitivity of the kits, poor consumer demand, pharmacists' lack of training and information, and a belief that selling FOBT kits was outside the pharmacists' scope of practice. Motivators to selling the kits included customer convenience, ease of use, confidence in the kits and embracing new roles for pharmacists. Pharmacists were concerned that use of the kits may increase the burden on the public health system through customer anxiety over test results; however, they agreed that there was a need for bowel cancer screening and awareness and that people concerned about bowel cancer should make visiting their general practitioner a priority. Pharmacists' views were mixed. Pharmacists' training and competence with respect to the provision of bowel cancer kits, and how a bowel cancer screening service can be developed to optimise public health outcomes, need to be addressed. © 2013 Royal Pharmaceutical Society.
Patel, Anuj V; Abrams, Samuel M; Gaydos, Charlotte A; Jett-Goheen, Mary; Latkin, Carl A; Rothman, Richard E; Hsieh, Yu-Hsiang
2018-06-14
Up to 60% of patients decline routine HIV testing offer in US emergency departments (EDs). The objective of this study is to determine whether the provision of HIV self-testing (HIVST) kit would increase engagement of HIV testing among these HIV test 'Decliners'. Patients who declined a test offered in an ED-based triage nurse-driven HIV screening programme were enrolled and randomised to either the HIVST or the control group. The patients in the HIVST group received HIVST kits to take home, were encouraged to report test results to an established internet-based STI/HIV testing recruitment website 'I Want the Kit' (IWTK) and received five referral cards for their peers to request HIVST kits from IWTK. The control group received pamphlets about publicly available HIV testing sites. HIV testing from both groups after enrolment was determined via telephone follow-up at 1 month. Testing rate ratio (RR) was determined using χ 2 tests. Fifty-two patients were randomised to the HIVST group and 48 to the control group. Among all 64 patients completing any follow-up, 14/29 (48%) patients in the HIVST group tested themselves at home with the provided kit. Four of these had never had an HIV test. Only 2/35 (6%) in the control group reported having an HIV test after enrolment (RR: 8.45 (95% CI: 2.09 to 34.17)). 57% (8/14) in the HIVST group reported test results to IWTK. Provision of HIVST kits supplements ED-based screening programme and significantly improved engagement of HIV testing among those test 'Decliners' in the ED. NCT03021005, results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Code of Federal Regulations, 2010 CFR
2010-01-01
... with ceiling fan light kits that have medium screw base sockets shall conform to the requirements... testing pin-based fluorescent lamps packaged with ceiling fan light kits that have pin-based sockets shall... base sockets, measure the efficacy, expressed in lumens per watt, in accordance with the test...
15 CFR 742.2 - Proliferation of chemical and biological weapons.
Code of Federal Regulations, 2011 CFR
2011-01-01
... medical, analytical, diagnostic, and food testing kits that consist of pre-packaged materials of defined... health purposes: (1) Test kits containing no more than 300 grams of any chemical controlled by ECCN 1C350... part 745 of the EAR). Such test kits are controlled by ECCN 1C395 for CB and CW reasons, to States not...
15 CFR 742.2 - Proliferation of chemical and biological weapons.
Code of Federal Regulations, 2013 CFR
2013-01-01
... medical, analytical, diagnostic, and food testing kits that consist of pre-packaged materials of defined... health purposes: (1) Test kits containing no more than 300 grams of any chemical controlled by ECCN 1C350... part 745 of the EAR). Such test kits are controlled by ECCN 1C395 for CB and CW reasons, to States not...
15 CFR 742.2 - Proliferation of chemical and biological weapons.
Code of Federal Regulations, 2014 CFR
2014-01-01
..., analytical, diagnostic, and food testing kits that consist of pre-packaged materials of defined composition... purposes: (1) Test kits containing no more than 300 grams of any chemical controlled by ECCN 1C350.b or .c... the EAR). Such test kits are controlled by ECCN 1C395 for CB and CW reasons, to States not Party to...
Matovu, Joseph Kb; Buregyeya, Esther; Arinaitwe, Jim; Wanyenze, Rhoda K
2017-11-01
In 2015, the World Health Organization reported that more than 60 million people were tested for HIV in 122 low- and middle-income countries between 2010 and 2014. Despite this level of progress, over 40% of people living with HIV remain unaware of their HIV status. This calls for innovative approaches to improve uptake of HIV testing services, including use of HIV self-test (HIVST) kits. We conducted a cross-sectional, qualitative study to assess pregnant women and their male partners' perceptions regarding female partner-delivered HIVST kits. This study was conducted at two health facilities in Central Uganda between November and December 2015. Data were collected on pregnant women's willingness to take HIVST kits to their male partners and other household members using eight focus group discussions and 30 in-depth interviews. Data were analyzed following a thematic framework approach. Overall, pregnant women were willing to take HIVST kits to their partners and other household members, with the exception of their cowives. Male partners were willing to use HIVST kits brought by their female partners. Our findings suggest that secondary distribution of HIVST kits through female partners is acceptable and has the potential to improve male partner and household-member HIV testing.
Young, Sean D.; Daniels, Joseph; Chiu, ChingChe J.; Bolan, Robert K.; Flynn, Risa P.; Kwok, Justin; Klausner, Jeffrey D.
2014-01-01
Introduction Rates of unrecognized HIV infection are significantly higher among Latino and Black men who have sex with men (MSM). Policy makers have proposed that HIV self-testing kits and new methods for delivering self-testing could improve testing uptake among minority MSM. This study sought to conduct qualitative assessments with MSM of color to determine the acceptability of using electronic vending machines to dispense HIV self-testing kits. Materials and Methods African American and Latino MSM were recruited using a participant pool from an existing HIV prevention trial on Facebook. If participants expressed interest in using a vending machine to receive an HIV self-testing kit, they were emailed a 4-digit personal identification number (PIN) code to retrieve the test from the machine. We followed up with those who had tested to assess their willingness to participate in an interview about their experience. Results Twelve kits were dispensed and 8 interviews were conducted. In general, participants expressed that the vending machine was an acceptable HIV test delivery method due to its novelty and convenience. Discussion Acceptability of this delivery model for HIV testing kits was closely associated with three main factors: credibility, confidentiality, and convenience. Future research is needed to address issues, such as user-induced errors and costs, before scaling up the dispensing method. PMID:25076208
Baker, Erin J.; Kellogg, Christina A.
2014-01-01
Coral microbiology is an expanding field, yet there is no standard DNA extraction protocol. Although many researchers depend on commercial extraction kits, no specific kit has been optimized for use with coral samples. Both soil and plant DNA extraction kits from MO BIO Laboratories, Inc., have been used by many research groups for this purpose. MO BIO recently replaced their PowerPlant® kit with an improved PowerPlantPro kit, but it was unclear how these changes would affect the kit’s use with coral samples. In order to determine which kit produced the best results, we conducted a comparison between the original PowerPlant kit, the new PowerPlantPro kit, and an alternative kit, PowerSoil, using samples from several different coral genera. The PowerPlantPro kit had the highest DNA yields, but the lack of 16S rRNA gene amplification in many samples suggests that much of the yield may be coral DNA rather than microbial DNA. The most consistent positive amplifications came from the PowerSoil kit.
Evaluation of a Commercial Latex Agglutination Test Kit for Cryptococcal Antigen
Kaufman, Leo; Cowart, Glenda; Blumer, Sharon; Stine, Amy; Wood, Ross
1974-01-01
Two dozen Crypto-LA kits for detecting Cryptococcus neoformans capsular polysaccharide antigens were evaluated. Ten kits proved reliable for detecting and titering antigen in clinical materials. Fourteen kits were found to be inadequate. PMID:4596394
The Environmental Technology Verification (ETV) Program, beginning as an initiative of the U.S. Environmental Protection Agency (EPA) in 1995, verifies the performance of commercially available, innovative technologies that can be used to measure environmental quality. The ETV ...
St George, K; Boyd, M J; Lipson, S M; Ferguson, D; Cartmell, G F; Falk, L H; Rinaldo, C R; Landry, M L
2000-04-01
A total of 513 blood specimens, predominantly from organ transplant recipients, human immunodeficiency virus-positive patients, and bone marrow transplant recipients, were tested for cytomegalovirus (CMV) by culture and pp65 antigenemia across four test sites. Peripheral blood leukocytes were examined by using both the Biotest CMV Brite and the Bartels/Argene CMV Antigenemia kits. A total of 109 specimens were positive for CMV, 106 (97%) were positive by antigenemia, and 34 (31%) were positive by culture. According to the manufacturers' instructions, 150,000 cells were applied per slide for the Biotest kit and 200,000 cells per slide for the Bartels kit. A total of 93 specimens (88%) were positive by the Biotest kit, and 86 (81%) were positive by the Bartels kit. In specimens found to be positive by only one kit, the positive cell counts were low (median, 1; range, 1 to 7). When the data from all four sites were combined and analyzed, there was no statistical difference between the performance of the two kits; the Biotest and Bartels kits were found to be equivalent in sensitivity, specificity, and positive and negative predictive values for the detection of CMV pp65 antigenemia.
Gan, Kok Beng; Azeez, Dhifaf; Umat, Cila; Ali, Mohd Alauddin Mohd; Wahab, Noor Alaudin Abdul; Mukari, Siti Zamratol Mai-Sarah
2012-10-01
Hearing screening is important for the early detection of hearing loss. The requirements of specialized equipment, skilled personnel, and quiet environments for valid screening results limit its application in schools and health clinics. This study aimed to develop an automated hearing screening kit (auto-kit) with the capability of realtime noise level monitoring to ensure that the screening is performed in an environment that conforms to the standard. The auto-kit consists of a laptop, a 24-bit resolution sound card, headphones, a microphone, and a graphical user interface, which is calibrated according to the American National Standards Institute S3.6-2004 standard. The auto-kit can present four test tones (500, 1000, 2000, and 4000 Hz) at 25 or 40 dB HL screening cut-off level. The clinical results at 40 dB HL screening cut-off level showed that the auto-kit has a sensitivity of 92.5% and a specificity of 75.0%. Because the 500 Hz test tone is not included in the standard hearing screening procedure, it can be excluded from the auto-kit test procedure. The exclusion of 500 Hz test tone improved the specificity of the auto-kit from 75.0% to 92.3%, which suggests that the auto-kit could be a valid hearing screening device. In conclusion, the auto-kit may be a valuable hearing screening tool, especially in countries where resources are limited.
Method and platform standardization in MRM-based quantitative plasma proteomics.
Percy, Andrew J; Chambers, Andrew G; Yang, Juncong; Jackson, Angela M; Domanski, Dominik; Burkhart, Julia; Sickmann, Albert; Borchers, Christoph H
2013-12-16
There exists a growing demand in the proteomics community to standardize experimental methods and liquid chromatography-mass spectrometry (LC/MS) platforms in order to enable the acquisition of more precise and accurate quantitative data. This necessity is heightened by the evolving trend of verifying and validating candidate disease biomarkers in complex biofluids, such as blood plasma, through targeted multiple reaction monitoring (MRM)-based approaches with stable isotope-labeled standards (SIS). Considering the lack of performance standards for quantitative plasma proteomics, we previously developed two reference kits to evaluate the MRM with SIS peptide approach using undepleted and non-enriched human plasma. The first kit tests the effectiveness of the LC/MRM-MS platform (kit #1), while the second evaluates the performance of an entire analytical workflow (kit #2). Here, these kits have been refined for practical use and then evaluated through intra- and inter-laboratory testing on 6 common LC/MS platforms. For an identical panel of 22 plasma proteins, similar concentrations were determined, regardless of the kit, instrument platform, and laboratory of analysis. These results demonstrate the value of the kit and reinforce the utility of standardized methods and protocols. The proteomics community needs standardized experimental protocols and quality control methods in order to improve the reproducibility of MS-based quantitative data. This need is heightened by the evolving trend for MRM-based validation of proposed disease biomarkers in complex biofluids such as blood plasma. We have developed two kits to assist in the inter- and intra-laboratory quality control of MRM experiments: the first kit tests the effectiveness of the LC/MRM-MS platform (kit #1), while the second evaluates the performance of an entire analytical workflow (kit #2). In this paper, we report the use of these kits in intra- and inter-laboratory testing on 6 common LC/MS platforms. This article is part of a Special Issue entitled: Standardization and Quality Control in Proteomics. © 2013.
Shiraishi, Rikiya; Nishiguchi, Akiko; Tsukamoto, Kenji; Muramatsu, Masatake
2012-09-01
We evaluated the utility of 5 commercial enzyme-linked immunosorbent assay (ELISA) kits for detecting antibodies to avian influenza viruses. The sensitivities and specificities of the ELISA kits were compared with those of the agar gel precipitation (AGP) and hemagglutination-inhibition (HI) tests. The results suggest that some ELISA kits might not be suitable for monitoring during the early stages of avian influenza virus infections. Therefore, ELISA kits should only be used in conjunction with a profound knowledge about monitoring of avian influenza.
Suslov, Anatoly P; Kuzin, Stanislav N; Golosova, Tatiana V; Shalunova, Nina V; Malyshev, Nikolai A; Sadikova, Natalia V; Vavilova, Lubov M; Somova, Anna V; Musina, Elena E; Ivanova, Maria V; Kipor, Tatiana T; Timonin, Igor M; Kuzina, Lubov E; Godkov, Mihail A; Bajenov, Alexei I; Nesterenko, Vladimir G
2002-07-01
When human sera samples are tested for anti-hepatitis C virus (HCV) antibodies using different ELISA kits as well as immunoblot assay kits discrepant results often occur. As a result the diagnostics of HCV infection in such sera remains unclear. The purpose of this investigation is to define the limits of HCV serodiagnostics. Overall 7 different test kits of domestic and foreign manufacturers were used for the sampled sera testing. Preliminary comparative study, using seroconversion panels PHV905, PHV907, PHV908 was performed and reference kit was chosen (Murex anti-HCV version 4) as the most sensitive kit on the base of this study results. Overall 1640 sera samples have been screened using different anti-HCV ELISA kits and 667 of them gave discrepant results in at least two kits. These sera were then tested using three anti-HCV ELISA kits (first set of 377 samples) or four anti-HCV ELISA kits (second set of 290 samples) at the conditions of reference laboratory. In the first set 17.2% samples remained discrepant and in the second set - 13.4%. "Discrepant" sera were further tested in RIBA 3.0 and INNO-LIA immunoblot confirmatory assays, but approximately 5-7% of them remained undetermined after all the tests. For the samples with signal-to-cutoff ratio higher than 3.0 high rate of result consistency by reference, ELISA routing and INNO-LIA immunoblot assay was observed. On the other hand the results of tests 27 "problematic" sera in RIBA 3.0 and INNO-LIA were consistent only in 55.5% cases. Analysis of the antigen spectrum reactive with antibodies in "problematic" sera, demonstrated predominance of Core, NS3 and NS4 antigens for sera, positive in RIBA 3.0 and Core and NS3 antigens for sera, positive in INNO-LIA. To overcome the problem of undetermined sera, methods based on other principles, as well as alternative criteria of HCV infection diagnostics are discussed.
LogiKit - assisting complex logic specification and implementation for embedded control systems
NASA Astrophysics Data System (ADS)
Diglio, A.; Nicolodi, B.
2002-07-01
LogiKit provides an overall lifecycle solution. LogiKit is a powerful software engineering case toolkit for requirements specification, simulation and documentation. LogiKit also provides an automatic ADA software design, code and unit test generator.
Psychometric Properties of the Concept Assessment Kit-Conservation.
ERIC Educational Resources Information Center
Lehnert, Linda; And Others
1986-01-01
This study investigated the psychometric properties of the Educational and Industrial Testing Service Concept Assessment Kit-Conservation (EITS Kit). Presented are an overview of the concept of conservation, a description of the EITS Kit, and results of the study. (MT)
Electronic vending machines for dispensing rapid HIV self-testing kits: a case study.
Young, Sean D; Klausner, Jeffrey; Fynn, Risa; Bolan, Robert
2014-02-01
This short report evaluates the feasibility of using electronic vending machines for dispensing oral, fluid, rapid HIV self-testing kits in Los Angeles County. Feasibility criteria that needed to be addressed were defined as: (1) ability to find a manufacturer who would allow dispensing of HIV testing kits and could fit them to the dimensions of a vending machine, (2) ability to identify and address potential initial obstacles, trade-offs in choosing a machine location, and (3) ability to gain community approval for implementing this approach in a community setting. To address these issues, we contracted a vending machine company who could supply a customized, Internet-enabled machine that could dispense HIV kits and partnered with a local health center available to host the machine onsite and provide counseling to participants, if needed. Vending machines appear to be feasible technologies that can be used to distribute HIV testing kits.
Electronic vending machines for dispensing rapid HIV self-testing kits: A case study
Young, Sean D.; Klausner, Jeffrey; Fynn, Risa; Bolan, Robert
2014-01-01
This short report evaluates the feasibility of using electronic vending machines for dispensing oral, fluid, rapid HIV-self testing kits in Los Angeles County. Feasibility criteria that needed to be addressed were defined as: 1) ability to find a manufacturer who would allow dispensing of HIV testing kits and could fit them to the dimensions of a vending machine, 2) ability to identify and address potential initial obstacles, trade-offs in choosing a machine location, and 3) ability to gain community approval for implementing this approach in a community setting. To address these issues, we contracted a vending machine company who could supply a customized, Internet-enabled machine that could dispense HIV kits and partnered with a local health center available to host the machine onsite and provide counseling to participants, if needed. Vending machines appear to be feasible technologies that can be used to distribute HIV testing kits. PMID:23777528
Zhang, Xiaomei; Zhou, Tingting; Yu, Wenjing; Ai, Jinxia; Wang, Xuesong; Gao, Lijun; Yuan, Guangxin; Li, Mingcheng
2018-01-01
We developed a kind of Zaocys dhumnades DNA test kit and it's indexes including specificity, sensitivity and stability were evaluated and compared with the method recorded in Chinese Pharmacopoeia (2010 edition). The bioinformatics technology was used to design primers, sequencing and blast, in conjunction with PCR technology based on the characteristics of Z. dhumnades cytochrome b (Cyt b) gene. The efficiency of nucleic acid extraction by the kit was done in accordance with Pharmacopoeia method. The kit stability results proved effective after repeated freezing and thawing 20 times. The sensitivity results indicated that the lowest amount detected by the kit was 0. 025 g of each specimen. The specificity test of the kit was 100% specific. All repeatability tests indicated the same results when conducted three times. Compared with the method recorded in Chinese Pharmacopoeia, the PCR-based assay kit by our team developed is accurate, effective in identification of Z. dhumnades, it is simple and fast, demonstrating a broad prospect in quality inspection of Z. dhumnades in the future.
The RemediAidTm Total Petroleum Hydrocarbon Starter Kit (RemediAidTm kit) developed by CHEMetries, Inc. (CHEMetrics), and AZUR Environmental Ltd was demonstrated under the U.S. Environmental Protection Agency Superfund Innovative Technology Evaluation Program in June 2000 at the ...
Mkit: A cell migration assay based on microfluidic device and smartphone.
Yang, Ke; Wu, Jiandong; Peretz-Soroka, Hagit; Zhu, Ling; Li, Zhigang; Sang, Yaoshuo; Hipolito, Jolly; Zhang, Michael; Santos, Susy; Hillier, Craig; de Faria, Ricardo Lobato; Liu, Yong; Lin, Francis
2018-01-15
Mobile sensing based on the integration of microfluidic device and smartphone, so-called MS 2 technology, has enabled many applications over recent years, and continues to stimulate growing interest in both research communities and industries. In particular, it has been envisioned that MS 2 technology can be developed for various cell functional assays to enable basic research and clinical applications. Toward this direction, in this paper, we describe the development of a MS 2 -based cell functional assay for testing cell migration (the M kit ). The system is constructed as an integrated test kit, which includes microfluidic chips, a smartphone-based imaging platform, the phone apps for image capturing and data analysis, and a set of reagent and accessories for performing the cell migration assay. We demonstrated that the M kit can effectively measure purified neutrophil and cancer cell chemotaxis. Furthermore, neutrophil chemotaxis can be tested from a drop of whole blood using the M kit with red blood cell (RBC) lysis. The effects of chemoattractant dose and gradient profile on neutrophil chemotaxis were also tested using the M kit . In addition to research applications, we demonstrated the effective use of the M kit for on-site test at the hospital and for testing clinical samples from chronic obstructive pulmonary disease patient. Thus, this developed M kit provides an easy and integrated experimental platform for cell migration related research and potential medical diagnostic applications. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Schneider, Michelle
2003-01-01
This viewgraph representation provides an overview of the Telescience Resource Kit. The Telescience Resource Kit is a pc-based telemetry and command system that will be used by scientists and engineers to monitor and control experiments located on-board the International Space Station (ISS). Topics covered include: ISS Payload Telemetry and Command Flow, kit computer applications, kit telemetry capabilities, command capabilities, and training/testing capabilities.
Chiu, ChingChe J; Young, Sean D
2016-01-01
High levels of HIV stigma are one of the main difficulties in engaging African-American and Latino men who have sex with men (MSM) in HIV testing. The availability of home HIV test and the possibility of self-testing in private may improve uptake and counteract stigma. This paper sought to determine the correlates of requesting home HIV test kits among a sample of MSM social media users. The odds of participants requesting a test kit were significantly associated with using social networks to seek sexual partners (aOR: 2.47, 95% CI: 1.07-6.06) and thinking it is easier to use social networks for seeking sexual partners (1.87, 1.2-3.12), uncertain HIV status (4.29, 1.37-14.4), and having sex under the influence of alcohol (2.46, 1.06-5.77). Participants who had not been tested for more than 6 months were more likely to request a test kit than those who were tested in the past 6 months (2.53, 1.02-6.37). Participants who frequently talked to others about having sex with men online were less likely to request a test kit (0.73, 0.56-0.92). By reaching people over social media and offering them access to test kits, we were able to reach at-risk individuals who were uncertain about their HIV status and had not been regularly tested. The findings of the study will help to inform future HIV testing interventions.
Self-Test Kit: Rapid Diagnosis of Urogenital Infections in Military Women
1998-09-01
tract infections or asymptomatic bacteriuria and symptoms from their cervical/vaginal infection. In many cases treatment of their cervical/vaginal...during the second year. We have thus far tested the kit in 234 women with genital complaints. The self-test kit results suggested appropriate treatment in...evaluation, diagnosis and treatment . All of these factors may significantly impact the ability and readiness of military women to perform their assigned
Desneux, Jérémy; Pourcher, Anne-Marie
2014-01-01
Four commercial DNA extraction kits and a minor modification in the DNA elution procedure were evaluated for the quantitation of bacteria in pig manure samples. The PowerSoil®, PowerFecal®, NucleoSpin® Soil kits and QIAamp® DNA Stool Mini kit were tested on raw manure samples and on lagoon effluents for their ability to quantify total bacteria and a subdominant bacteria specific of pig manure contamination: Lactobacillus amylovorus. The NucleoSpin® Soil kit (NS kit), and to a lesser extent the PowerFecal® kit were the most efficient methods. Regardless of the kit utilized, the modified elution procedure increased DNA yield in the lagoon effluent by a factor of 1.4 to 1.8. When tested on 10 piggery effluent samples, compared to the QIAamp kit, the NS kit combined with the modified elution step, increased by a factor up to 1.7 log10 the values of the concentration of L. amylovorus. Regardless of the type of manure, the best DNA quality and the highest concentrations of bacteria were obtained using the NS kit combined with the modification of the elution procedure. The method recommended here significantly improved quantitation of subdominant bacteria in manure. PMID:24838631
C-MORE Science Kits: Putting Technology in the Hands of K-12 Teachers and Students
NASA Astrophysics Data System (ADS)
Achilles, K.; Weersing, K.; Daniels, C.; Puniwai, N.; Matsuzaki, J.; Bruno, B. C.
2008-12-01
The Center for Microbial Oceanography: Research and Education (C-MORE) is a NSF Science and Technology Center based at the University of Hawaii. The C-MORE education and outreach program offers a variety of resources and professional development opportunities for science educators, including online resources, participation in oceanography research cruises, teacher-training workshops, mini-grants to incorporate microbial oceanography-related content and activities into their classroom and, most recently, C- MORE science kits. C-MORE science kits provide hands-on classroom, field, and laboratory activities related to microbial oceanography for K-12 students. Each kit comes with complete materials and instructions, and is available free of charge to Hawaii's public school teachers. Several kits are available nationwide. C-MORE science kits cover a range of topics and technologies and are targeted at various grade levels. Here is a sampling of some available kits: 1) Marine Murder Mystery: The Case of the Missing Zooxanthellae. Students learn about the effect of climate change and other environmental threats on coral reef destruction through a murder-mystery experience. Participants also learn how to use DNA to identify a suspect. Grades levels: 3-8. 2) Statistical sampling. Students learn basic statistics through an exercise in random sampling, with applications to microbial oceanography. The laptops provided with this kit enable students to enter, analyze, and graph their data using EXCEL. Grades levels: 6-12. 3) Chlorophyll Lab. A research-quality fluorometer is used to measure the chlorophyll content in marine and freshwater systems. This enables students to compare biomass concentrations in samples collected from various locations. Grades levels: 9-12. 4) Conductivity-Temperature-Depth (CTD). Students predict how certain variables (e.g., temperature, pressure, chlorophyll, oxygen) vary with depth. A CTD, attached to a laptop computer, is deployed into deep water off a dock or a ship to collect real-time data and test their hypotheses. Grades levels: 9-12.
Campbell, Rebecca; Fehler-Cabral, Giannina; Bybee, Deborah; Shaw, Jessica
2017-10-01
Throughout the United States, hundreds of thousands of sexual assault kits (SAKs) (also termed "rape kits") have not been submitted by the police for forensic DNA testing. DNA evidence can help sexual assault investigations and prosecutions by identifying offenders, revealing serial offenders through DNA matches across cases, and exonerating those who have been wrongly accused. In this article, we describe a 5-year action research project conducted with 1 city that had large numbers of untested SAKs-Detroit, Michigan-and our examination into why thousands of rape kits in this city were never submitted for forensic DNA testing. This mixed methods study combined ethnographic observations and qualitative interviews to identify stakeholders' perspectives as to why rape kits were not routinely submitted for testing. Then, we quantitatively examined whether these factors may have affected police practices regarding SAK testing, as evidenced by predictable changes in SAK submission rates over time. Chronic resource scarcity only partially explained why the organizations that serve rape victims-the police, crime lab, prosecution, and victim advocacy-could not test all rape kits, investigate all reported sexual assaults, and support all rape survivors. SAK submission rates significantly increased once criminal justice professionals in this city had full access to the FBI DNA forensic database Combined DNA Index System (CODIS), but even then, most SAKs were still not submitted for DNA testing. Building crime laboratories' capacities for DNA testing and training police on the utility of forensic evidence and best practices in sexual assault investigations can help remedy, and possibly prevent, the problem of untested rape kits. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
NASA Astrophysics Data System (ADS)
Solano-Altamirano, J. M.; Hernández-Pérez, Julio M.
2015-11-01
DensToolKit is a suite of cross-platform, optionally parallelized, programs for analyzing the molecular electron density (ρ) and several fields derived from it. Scalar and vector fields, such as the gradient of the electron density (∇ρ), electron localization function (ELF) and its gradient, localized orbital locator (LOL), region of slow electrons (RoSE), reduced density gradient, localized electrons detector (LED), information entropy, molecular electrostatic potential, kinetic energy densities K and G, among others, can be evaluated on zero, one, two, and three dimensional grids. The suite includes a program for searching critical points and bond paths of the electron density, under the framework of Quantum Theory of Atoms in Molecules. DensToolKit also evaluates the momentum space electron density on spatial grids, and the reduced density matrix of order one along lines joining two arbitrary atoms of a molecule. The source code is distributed under the GNU-GPLv3 license, and we release the code with the intent of establishing an open-source collaborative project. The style of DensToolKit's code follows some of the guidelines of an object-oriented program. This allows us to supply the user with a simple manner for easily implement new scalar or vector fields, provided they are derived from any of the fields already implemented in the code. In this paper, we present some of the most salient features of the programs contained in the suite, some examples of how to run them, and the mathematical definitions of the implemented fields along with hints of how we optimized their evaluation. We benchmarked our suite against both a freely-available program and a commercial package. Speed-ups of ˜2×, and up to 12× were obtained using a non-parallel compilation of DensToolKit for the evaluation of fields. DensToolKit takes similar times for finding critical points, compared to a commercial package. Finally, we present some perspectives for the future development and growth of the suite.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peles, Slaven
2016-11-06
GridKit is a software development kit for interfacing power systems and power grid application software with high performance computing (HPC) libraries developed at National Labs and academia. It is also intended as interoperability layer between different numerical libraries. GridKit is not a standalone application, but comes with a suite of test examples illustrating possible usage.
Neutral Buoyancy Simulator - Fluid line repair kit development
NASA Technical Reports Server (NTRS)
1997-01-01
Marshall's Neutral Buoyancy Simulator (NBS) is used to simulate the gravitational fields and buoyancy effects outer space has on astronauts and their ability to perform tasks in this environment. In this example, a diver performs a temporary fluid line repair task using a repair kit developed by Marshall engineers. The analysis will determine the value of this repair kit and its feasibility.
Veerasami, Maroudam; Venkataraman, K; Karuppannan, Chitra; Shanmugam, Arun Attur; Prudhvi, Mallepaddi Chand; Holder, Thomas; Rathnagiri, Polavarapu; Arunmozhivarman, K; Raj, Gopal Dhinakar; Vordermeier, Martin; Mohana Subramanian, B
2018-03-01
Tuberculosis is a significant problem globally for domestic animals as well as captive and free ranging wild life. Rapid point of care (POC) serology kits are well suited for the diagnosis of TB in wild animals. However, wild animals are invariably exposed to environmental non-pathogenic mycobacterium species with the development of cross reacting antibodies. In the present study, POC TB diagnosis kit was developed using a combination of pathogenic Mycobacteria specific recombinant antigens and purified protein derivatives of pathogenic and non-pathogenic Mycobacteria . To benchmark the TB antibody detection kit, particularly in respect to specificity which could not be determined in wildlife due to the lack of samples from confirmed uninfected animals, we first tested well-characterized sera from 100 M. bovis infected and 100 uninfected cattle. Then we investigated the kit's performance using sera samples from wildlife, namely Sloth Bears (n = 74), Elephants (n = 9), Cervidae (n = 14), Felidae (n = 21), Cape buffalo (n = 2), Wild bear (n = 1) and Wild dog (n = 1).In cattle, a sensitivity of 81% and a specificity of 90% were obtained. The diagnostic sensitivity of the kit was 94% when the kit was tested using known TB positive sloth bear sera samples. 47.4% of the in-contact sloth bears turned seropositive using the rapid POC TB diagnostic kit. Seropositivity in other wild animals was 25% when the sera samples were tested using the kit. A point of care TB sero-diagnostic kit with the combination of proteins was developed and the kit was validated using the sera samples of wild animals.
Zhang, Jun; Zhong, Jing; Ding, Jian; Shi, Jiemin; Tang, Tao; Liu, Qiqi; Huang, Huilian; Dai, Licheng; Yang, Ningmin
2018-06-01
A personalised diagnosis kit for Helicobacter pylori that employs visual gene chip technology for the simultaneous detection of CYP2C19 polymorphisms and clarithromycin/levofloxacin antibiotic resistance was evaluated. Gastric antrum mucosa biopsy specimens of 394 patients were tested using the kit. DNA sequencing and antibiotic susceptibility testing of the H. pylori were also performed. In total, 267 (67.8%) of the 394 specimens were positive for H. pylori using the kit and DNA sequencing, and 136 (34.5%) were positive by culturing. For human CYP2C19 and the bacterial 23S rRNA and gyrA genes, the concordance rates were 92.4% (364/394), 96.6% (258/267) and 97.0% (259/267) between the kit and DNA sequencing results, respectively. For clarithromycin and levofloxacin resistance, the concordance rates were 90.4% (123/136) and 81.6% (111/136) between the kit and antibiotic susceptibility testing results. The personalised diagnosis kit for H. pylori provides useful information for the choice of proton pump inhibitor and antibiotic in combination therapy. Copyright © 2018 International Society for Chemotherapy of Infection and Cancer. Published by Elsevier Ltd. All rights reserved.
Two brothers' alleged paternity for a child: who is the father?
Dogan, Muhammed; Kara, Umut; Emre, Ramazan; Fung, Wing Kam; Canturk, Kemal Murat
2015-06-01
In paternity cases where individuals are close relatives, it may be necessary to evaluate mother's DNA profile (trio test) and to increase the number of polymorphic STR loci that are analyzed. In our case, two alleged fathers who are brothers and the child (duo case) were analyzed based on 20 STR loci; however, no exclusions could be achieved. Then trio test (with mother) was performed using the Identifiler Plus kit (Applied Biosystems) and no exclusions could be achieved again. Analysis performed with the ESS Plex Plus kit (Qiagen), the paternity of one of the two alleged fathers was rejected only on 2 STR loci. We made the calculations of power of exclusion values to interpret our results more properly. The probability of exclusion (PE) is calculated as 0.9776546 in 15 loci of Identifiler Plus kit without mother. The PE is calculated as 0.9942803, if 5 additional loci from ESS Plex Plus kit are typed. The PE becomes 0.9961048 for the Identifiler Plus kit in trio analysis. If both Identifiler Plus and ESS Plex Plus kits are used for testing, the PE is calculated as 0.999431654, which indicates that the combined kits are highly discriminating.
The diagnostic value of troponin T testing in the community setting.
Planer, David; Leibowitz, David; Paltiel, Ora; Boukhobza, Rina; Lotan, Chaim; Weiss, Teddy A
2006-03-08
Many patients presenting with chest pain to their family physician are referred to the emergency room, in part, due to lack of accurate objective diagnostic tools. This study aimed to assess the diagnostic value of bedside troponin T kit testing in patients presenting with chest pain to their family physician. Prospective, multi-center study. Consecutive subjects with chest pain were recruited from 44 community clinics in Jerusalem. Following clinical assessment by the family physician, qualitative troponin kit testing was performed. Patients with a negative clinical assessment and negative troponin kit were sent home and all others were referred to the emergency room. The final diagnosis at the time of hospital discharge was recorded and telephone follow up was performed after 60 days. Positive predictive value, negative predictive value, sensitivity and specificity of troponin kit for myocardial infarction diagnosis and of family physician for hospitalization, were assessed. Of 392 patients enrolled, 349 (89%) were included in the final analysis. The prevalence of myocardial infarction was 1.7%. The positive and negative predictive values of the troponin kit for myocardial infarction diagnosis were 100% and 99.7%, respectively. The positive and negative predictive values of the family physician's assessment to predict hospitalization were 41.4% and 94.1%, respectively. Troponin kit testing is an important tool to assist the family physician in the assessment of patients with chest pain in the community setting. Troponin kit testing may identify otherwise undiagnosed cases of myocardial infarctions, and reduce unnecessary referrals to the emergency room.
Kang, Keren; Dzakah, Emmanuel E; Huang, Yongping; Xie, Mingquan; Luo, Xiaochun; Li, Wenmei; Wang, Jihua
2015-05-30
The low sensitivity and specificity of Plasmodium falciparum diagnostic tests pose a serious health threat to people living in endemic areas. The objective of the study was to develop a rapid assay for the detection of histidine-rich protein 2 (HRP2) of P. falciparum in whole blood by immunofluorescence chromatographic technology. A total of 1163 positive and negative blood samples were screened. The double-antibody sandwich assay was used to establish the kit and its performance was evaluated for sensitivity, specificity, accuracy, precision, stability, and clinical effectiveness. The cut-off level of detection of the kit was 25 parasites/μl. Common interfering substances in human blood specimens, such as bilirubin, triglyceride and cholesterol had no significant effect on HRP2 antigen detection. The precision of the kit was run with different concentration of standard calibrators and the values were less than 10 %. The performance of this diagnostic kit in the detection of the calibrators has shown that a shelf life of about 12 months gives a more reliable result. Among clinical samples tested, the HRP2 test kit and the reference products had good coincidence rate in a parallel experiment and this test kit had a more sensitive detecting level to the target protein than the reference kits used in this study. The specificity and sensitivity for this test were 99.6 % (800/803) and 99.7 % (1160/1163), respectively. A novel HRP2 immunofluorescence detection method was developed in this study. Overall performance evaluation indicated that the kit has a rapid, high sensitivity and on-spot method for detecting P. falciparum.
Volatile organic compound sensor system
Schabron, John F [Laramie, WY; Rovani, Jr., Joseph F.; Bomstad, Theresa M [Laramie, WY; Sorini-Wong, Susan S [Laramie, WY
2009-02-10
Generally, this invention relates to the development of field monitoring methodology for new substances and sensing chemical warfare agents (CWAs) and terrorist substances. It also relates to a portable test kit which may be utilized to measure concentrations of halogenated volatile organic compounds (VOCs) in the field. Specifically it relates to systems for reliably field sensing the potential presence of such items while also distinguishing them from other elements potentially present. It also relates to overall systems and processes for sensing, reacting, and responding to an indicated presence of such substance, including modifications of existing halogenated sensors and arrayed sensing systems and methods.
Volatile organic compound sensor system
Schabron, John F.; Rovani, Jr., Joseph F.; Bomstad, Theresa M.; Sorini-Wong, Susan S.; Wong, Gregory K.
2011-03-01
Generally, this invention relates to the development of field monitoring methodology for new substances and sensing chemical warfare agents (CWAs) and terrorist substances. It also relates to a portable test kit which may be utilized to measure concentrations of halogenated volatile organic compounds (VOCs) in the field. Specifically it relates to systems for reliably field sensing the potential presence of such items while also distinguishing them from other elements potentially present. It also relates to overall systems and processes for sensing, reacting, and responding to an indicated presence of such substance, including modifications of existing halogenated sensors and arrayed sensing systems and methods.
21 CFR 872.3600 - Partially fabricated denture kit.
Code of Federal Regulations, 2010 CFR
2010-04-01
... with the oral tissues. After the denture base is constructed, the connected preformed teeth are...: Evaluation and Testing,’ ” and (2) “OTC Denture Reliners, Repair Kits, and Partially Fabricated Denture Kits...
10 CFR 429.33 - Ceiling fan light kits.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Ceiling fan light kits. 429.33 Section 429.33 Energy... COMMERCIAL AND INDUSTRIAL EQUIPMENT Certification § 429.33 Ceiling fan light kits. (a) Sampling plan for selection of units for testing. (1) The requirements of § 429.11 are applicable to ceiling fan light kits...
10 CFR 429.33 - Ceiling fan light kits.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Ceiling fan light kits. 429.33 Section 429.33 Energy... COMMERCIAL AND INDUSTRIAL EQUIPMENT Certification § 429.33 Ceiling fan light kits. (a) Sampling plan for selection of units for testing. (1) The requirements of § 429.11 are applicable to ceiling fan light kits...
10 CFR 429.33 - Ceiling fan light kits.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Ceiling fan light kits. 429.33 Section 429.33 Energy... COMMERCIAL AND INDUSTRIAL EQUIPMENT Certification § 429.33 Ceiling fan light kits. (a) Sampling plan for selection of units for testing. (1) The requirements of § 429.11 are applicable to ceiling fan light kits...
Rapid Detection of the Varicella Zoster Virus
NASA Technical Reports Server (NTRS)
Lewis, Michelle P.; Harding, Robert
2011-01-01
1.Technology Description-Researchers discovered that when the Varicella Zoster Virus (VZV) reactivates from latency in the body, the virus is consistently present in saliva before the appearance of skin lesions. A small saliva sample is mixed with a specialized reagent in a test kit. If the virus is present in the saliva sample, the mixture turns a red color. The sensitivity and specificity emanates from an antibody-antigen reaction. This technology is a rapid, non-invasive, point of-of-care testing kit for detecting the virus from a saliva sample. The device is easy to use and can be used in clinics and in remote locations to quickly detect VZV and begin treatment with antiviral drugs. 2.Market Opportunity- RST Bioscience will be the first and only company to market a rapid, same day test kit for the detection of VZV in saliva. The RST detection test kit will have several advantages over existing, competitive technology. The test kit is self contained and laboratory equipment is not required for analysis of the sample. Only a single saliva sample is required to be taken instead of blood or cerebral spinal fluid. The test kit is portable, sterile and disposable after use. RST detection test kits require no electrical power or expensive storage equipment and can be used in remote locations. 3.Market Analysis- According to the CDC, it is estimated that 1 million cases of shingles occur each year in the U.S. with more than half over the age of sixty. There is a high demand for rapid diagnostics by the public. The point-of-care testing (POCT) market is growing faster than other segments of in vitro diagnostics. According to a July 2007 InteLab Corporation industry report the overall market for POCT was forecast to increase from $10.3 billion in 2005 to $18.7 billion by 2011. The market value of this test kit has not been determined. 4.Competition- The VZV vaccine prevents 50% of cases and reduces neuralgia by 66%. The most popular test detects VZV-specific IgM antibody in blood. Other tests include running a sample in a polymerase chain reaction analyzer, enzyme immunoassay, latex agglutination, indirect fluorescent antibody and fluorescent antibody to membrane antigen assay. These existing tests require laboratory analysis by trained personnel, expensive equipment, invasive procedures and a longer period of time to obtain test results.
Mills, S C; Mourier, J; Galzin, R
2010-08-01
Commercially available enzyme immunoassay (EIA) kits were validated for measuring steroid hormone concentrations in blood plasma from three fish species: the orange clownfish Amphiprion percula, the orangefin anemonefish Amphiprion chrysopterus and the blacktip reef shark Carcharhinus melanopterus. A minimum of 5 microl plasma was required to estimate hormone concentrations with both kits. These EIA kits are a simple method requiring minimal equipment, for measuring hormone profiles under field conditions.
Novel versatile smart phone based Microplate readers for on-site diagnoses.
Fu, Qiangqiang; Wu, Ze; Li, Xiuqing; Yao, Cuize; Yu, Shiting; Xiao, Wei; Tang, Yong
2016-07-15
Microplate readers are important diagnostic instruments, used intensively for various readout test kits (biochemical analysis kits and ELISA kits). However, due to their expensive and non-portability, commercial microplate readers are unavailable for home testing, community and rural hospitals, especially in developing countries. In this study, to provide a field-portable, cost-effective and versatile diagnostic tool, we reported a novel smart phone based microplate reader. The basic principle of this devise relies on a smart phone's optical sensor that measures transmitted light intensities of liquid samples. To prove the validity of these devises, developed smart phone based microplate readers were applied to readout results of various analytical targets. These targets included analanine aminotransferase (ALT; limit of detection (LOD) was 17.54 U/L), alkaline phosphatase (AKP; LOD was 15.56 U/L), creatinine (LOD was 1.35μM), bovine serum albumin (BSA; LOD was 0.0041mg/mL), prostate specific antigen (PSA; LOD was 0.76pg/mL), and ractopamine (Rac; LOD was 0.31ng/mL). The developed smart phone based microplate readers are versatile, portable, and inexpensive; they are unique because of their ability to perform under circumstances where resources and expertize are limited. Copyright © 2016 Elsevier B.V. All rights reserved.
Evaluation of aftermarket LPG conversion kits in light-duty vehicle applications. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bass, E A
1993-06-01
SwRI was contracted by NREL to evaluate three LPG conversion kits on a Chevrolet Lumina. The objective of the project was to measure the Federal Test Procedure (FTP) emissions and fuel economy of these kits, and compare their performance to gasoline-fueled operation and to each other. Varying LPG fuel blends allowed a preliminary look at the potential for fuel system disturbance. The project required kit installation and adjustment according to manufacturer`s instructions. A limited amount of trouble diagnosis was also performed on the fuel systems. A simultaneous contract from the Texas Railroad Commission, in cooperation with NREL, provided funds formore » additional testing with market fuels (HD5 propane and industry average gasoline) and hydrocarbon (HC) emissions speciation to determine the ozone-forming potential of LPG HC emissions. This report documents the procurement, installation, and testing of these LPG conversion kits.« less
IDENTIFYING ESCHERICHIA SPECIES WITH BIOCHEMICAL TEST KITS AND STANDARD BACTERIOLOGICAL TESTS
Two commercially available biochemical test systems were evaluated for their ability to accurately identify speies of the genus Escherichia. Three laboratories participated in the study. The test kits did not always correctly identify species of Escherichia, but only once was a...
Jennings, Larissa; Conserve, Donaldson F; Merrill, Jamison; Kajula, Lusajo; Iwelunmor, Juliet; Linnemayr, Sebastian; Maman, Suzanne
2017-01-01
Impoverished men have lower rates of facility-based HIV counseling and testing and higher unknown HIV-positive status than women. Economic theory suggests that individuals will obtain an HIV test if anticipated benefits are greater than anticipated costs. Yet, few studies have investigated the range of financial preferences of HIV self-testing (HIVST) among poor men who decline testing or do not test regularly. Twenty-three interviews were conducted to qualitatively assess perceived costs saved and costs incurred from use of HIVST kits in infrequently- or never-tested Tanzanian men. All men were shown an HIVST kit and video. They were then asked about the costs associated with provider-led HIV testing, financial benefits and concerns of HIVST and willingness to pay for HIVST. Data were transcribed, coded and analyzed using inductive content analyses. We then grouped codes into perceived cost advantages and disadvantages and tabulated the range of prices men were willing to pay for a self-test kit. Perceived cost advantages of HIVST were avoidance of spending money to test in facilities, omission of follow-up fees, affordability relative to private clinics, and increased time for earning income and other activities. Men also discussed the imbalance of the financial benefit of accessing free, public HIV testing with the resources spent for transport, purchasing meals away from home and long wait lines. Perceived cost disadvantages of HIVST were prohibitive kit costs, required prior savings to purchase kits, expenditures relating to death and preferences for free provider-performed testing. Men were also concerned about the psychological costs of inaccurate results. HIVST willingness to pay varied among men. Men’s decisions to self-test for HIV takes into account expected financial gains and losses. Demand generation for HIVST among men should consider use of low fees or free HIVST, while emphasizing potential savings from reduced travel, clinical costs, or time way from work. Efforts are also needed to address anticipated emotional costs of HIVST, such as anxiety from kit errors, purchasing “death” or testing alone, which for some men was a substantial barrier. PMID:29051841
Jennings, Larissa; Conserve, Donaldson F; Merrill, Jamison; Kajula, Lusajo; Iwelunmor, Juliet; Linnemayr, Sebastian; Maman, Suzanne
2017-08-01
Impoverished men have lower rates of facility-based HIV counseling and testing and higher unknown HIV-positive status than women. Economic theory suggests that individuals will obtain an HIV test if anticipated benefits are greater than anticipated costs. Yet, few studies have investigated the range of financial preferences of HIV self-testing (HIVST) among poor men who decline testing or do not test regularly. Twenty-three interviews were conducted to qualitatively assess perceived costs saved and costs incurred from use of HIVST kits in infrequently- or never-tested Tanzanian men. All men were shown an HIVST kit and video. They were then asked about the costs associated with provider-led HIV testing, financial benefits and concerns of HIVST and willingness to pay for HIVST. Data were transcribed, coded and analyzed using inductive content analyses. We then grouped codes into perceived cost advantages and disadvantages and tabulated the range of prices men were willing to pay for a self-test kit. Perceived cost advantages of HIVST were avoidance of spending money to test in facilities, omission of follow-up fees, affordability relative to private clinics, and increased time for earning income and other activities. Men also discussed the imbalance of the financial benefit of accessing free, public HIV testing with the resources spent for transport, purchasing meals away from home and long wait lines. Perceived cost disadvantages of HIVST were prohibitive kit costs, required prior savings to purchase kits, expenditures relating to death and preferences for free provider-performed testing. Men were also concerned about the psychological costs of inaccurate results. HIVST willingness to pay varied among men. Men's decisions to self-test for HIV takes into account expected financial gains and losses. Demand generation for HIVST among men should consider use of low fees or free HIVST, while emphasizing potential savings from reduced travel, clinical costs, or time way from work. Efforts are also needed to address anticipated emotional costs of HIVST, such as anxiety from kit errors, purchasing "death" or testing alone, which for some men was a substantial barrier.
Infantino, M; Meacci, F; Grossi, V; Manfredi, M; Benucci, M; Merone, M; Soda, P
2017-02-01
According to the recent recommendations of the American College of Rheumatology, ANA Task Force, IIF technique should be considered the gold standard in antinuclear antibodies (ANAs) testing. To overcome the lack of standardization, biomedical industries have developed several computer-aided diagnosis (CAD) systems. Two hundred and sixty-one consecutive samples with suspected autoimmune diseases were tested for ANA by means of IIF on routinely HEp-2 assay kit (Euroimmun AG). Assignment of result was made if consensus for positive/negative was reached by at least 2 out of 3 expert physicians. ANA-IIF was also carried out using 3 CAD systems: Zenit G-Sight (n = 84), Helios (n = 85) and NOVA View (n = 92); human evaluation was repeated on the same substrate of each CAD system (Immco, Aesku and Inova HEp-2 cells, respectively). To anonymize the results, we randomly named these three systems as A, B and C. We ran a statistical analysis computing several measures of agreement between the ratings, and we also improved the evaluation by using the Wilcoxon's test for nonparametric data. Agreement between the human readings on routinely HEp-2 assay kit and human readings on CAD HEp-2 assay was substantial for A (k = 0.82) and B (k = 0.72), and almost perfect for C (k = 0.89). Such readings were statistically different only in case A. Comparing experts' readings with the readings of CAD systems, when the samples were prepared using CAD HEp-2 assay kits, we found almost perfect agreement for B and C (k = 0.86; k = 0.82) and substantial agreement for A (k = 0.73). Again, human and CAD readings were statistically different only in A. When we compared the readings of medical experts on routinely HEp-2 assay kit with the output of the CAD systems that worked using their own slides, we found substantial agreement for all the systems (A: k = 0.62; B: k = 0.65; C: k = 0.71). Such readings were not statistically different. The change of the assay kit and/or the introduction of a CAD system affect the laboratory reporting, with an evident impact on the autoimmune laboratory workflow. The CAD systems may represent one of the most important novel elements of harmonization in the autoimmunity field, reducing intra- and inter-laboratory variability in a new vision of the diagnostic autoimmune platform.
An evaluation of suspicious powder screening tools for first responders.
Poore, Carrie; Clark, Paul; Emanuel, Peter A
2009-12-30
Field screening tools are required which would allow first responders to quickly ascertain if a suspicious powder poses a potential threat necessitating additional testing for biological pathogens such as Bacillus anthracis. In this study, three commercially available generic screening technologies were evaluated for the effectiveness to accurately differentiate between a hoax powder and a true biological threat. The BioCheck Kit was able to detect the following biological agents 1 x 10(8)CFU of B. anthracis Sterne (washed 4 times), 1x10(7)CFU of B. anthracis DeltaSterne (washed 2 times), 1 x 10(7)CFU of Yersinia pestis A1122, and 100 microg of ricin. The Prime Alert kit was able to detect 2 x 10(10)CFU of B. anthracis DeltaSterne 4x, 1 x 10(9)CFU of B. anthracis DeltaSterne 2x, and 1 x 10(8)CFU of Y. pestis A1122. The Prime Alert kit was not able to detect ricin. The Profile-1 kit was able to detect 1 x 10(4)CFU of B. anthracis DeltaSterne 4x and B. anthracis DeltaSterne 2x, and 1 x 10(6)CFU of Y. pestis A1122. The Profile-1 kit was not able to detect ricin. All of the kits showed positive results for powders containing components specifically targeted by the particular technology being used. Each technology assessed in this evaluation employs a different mechanism for the detection of biological materials and it is important that first responders are aware of the strengths and the limitations of each system so that they can effectively employ the technology to protect the homeland.
Eichmiller, Jessica J; Miller, Loren M; Sorensen, Peter W
2016-01-01
Few studies have examined capture and extraction methods for environmental DNA (eDNA) to identify techniques optimal for detection and quantification. In this study, precipitation, centrifugation and filtration eDNA capture methods and six commercially available DNA extraction kits were evaluated for their ability to detect and quantify common carp (Cyprinus carpio) mitochondrial DNA using quantitative PCR in a series of laboratory experiments. Filtration methods yielded the most carp eDNA, and a glass fibre (GF) filter performed better than a similar pore size polycarbonate (PC) filter. Smaller pore sized filters had higher regression slopes of biomass to eDNA, indicating that they were potentially more sensitive to changes in biomass. Comparison of DNA extraction kits showed that the MP Biomedicals FastDNA SPIN Kit yielded the most carp eDNA and was the most sensitive for detection purposes, despite minor inhibition. The MoBio PowerSoil DNA Isolation Kit had the lowest coefficient of variation in extraction efficiency between lake and well water and had no detectable inhibition, making it most suitable for comparisons across aquatic environments. Of the methods tested, we recommend using a 1.5 μm GF filter, followed by extraction with the MP Biomedicals FastDNA SPIN Kit for detection. For quantification of eDNA, filtration through a 0.2-0.6 μm pore size PC filter, followed by extraction with MoBio PowerSoil DNA Isolation Kit was optimal. These results are broadly applicable for laboratory studies on carps and potentially other cyprinids. The recommendations can also be used to inform choice of methodology for field studies. © 2015 John Wiley & Sons Ltd.
ACER and University of Melbourne Music Evaluation Kit. Handbook and Report.
ERIC Educational Resources Information Center
Bryce, Jennifer
The Melbourne Music Evaluation Kit (MEK) was designed to aid teachers of first-year secondary-school music classes to select appropriate curriculum materials related to the music backgrounds of class members, as indicated by scores on the kit. Tests included in the kit are criterion- referenced and are used as a diagnostic tool to measure…
Sharma, Chhavi; Singh, Mithilesh; Upmanyu, Vikramaditya; Chander, Vishal; Verma, Suman; Chakrovarty, Soumendu; Sharma, Gaurav K; Dhanze, Himani; Singh, Praveen; Shrivastava, Sameer; Kumar, Jyoti; Goswami, Tapas Kumar; Gupta, V K
2018-05-08
Canine parvovirus (CPV) is the leading viral cause of enteritis in dogs and occurs mainly in 6- to 8-week-old pups. Rapid diagnosis of CPV under field conditions is now possible due to commercially available immunochromatographic (IC) assays. However, these commercial kits are somewhat expensive because they utilize a minimum of two monoclonal antibodies (mAbs) targeting different epitopes as capture and detector antibodies. Using only a single mAb for both capture and detection purpose may reduce the sensitivity of the assay. In the present study, efforts were made to develop an economical assay that can be utilized for diagnosis of CPV under Indian conditions with a high level of confidence. Rabbit polyclonal antibodies (pAbs) generated against recombinant truncated VP2 proteins of CPV were used as capture antibodies because they can be produced economically, while a commercial anti-CPV mAb was used as the detector antibody. The detection limit of the test strip was 6.6×10 5 TCID 50 /ml, and it specifically detected CPV-2, CPV-2a and CPV-2b while displaying no cross-reactivity with other common canine enteric pathogens. The relative sensitivity/specificity of pAb based strip test was 71%/92% and 71%/100% in relation to the hemagglutination test and a commercial IC kit, respectively, with substantial agreement. In addition, two commercially available mAbs targeting different epitopes were also used for development of another IC assay, which showed sensitivity, and specificity of 82%/87% and 90%/98% in relation to the hemagglutination test and commercial kit. Hence, the present strip test based on a combination of mAb and pAb provides an acceptable alternative for onsite and cost-effective diagnosis of CPV infection.
Anitharaj, Velmurugan; Stephen, Selvaraj; Pradeep, Jothimani; Park, Sungman; Kim, Seung-Han; Kim, Young Jin; Kim, Eun-Ye; Kim, Yoon-Won
2016-11-01
Scrub Typhus (ST) is being reported from different parts of India in the recent past. However, the diagnosis and confirmation of ST cases require specific serological and molecular diagnostic tests. Both rapid and conventional ELISA tests need to be properly evaluated. Evaluation of a new ST IgM Immunochromatography (ICT) test kit (InBios Scrub Typhus Detect IgM Rapid Test) and compare it with another rapid kit, conventional ELISA kit and Weil-Felix (WF) test. This prospective study was carried out in Mahatma Gandhi Medical College and Research Institute, Puducherry, during November 2015 to June 2016. Clinically suspected 220 ST patients were examined by a new kit, InBios Scrub Typhus Detect IgM Rapid Test, taking the conventional InBios Scrub Typhus Detect IgM ELISA as reference. Additional comparison was made with ImmuneMed Scrub Typhus Rapid, and WF test (single OXK titers ≥1:320). Statistical analysis was performed (Chi-square, Spearman's correlation and Kappa) using IBM SPSS Statistics 17 for Windows (SPSS Inc; Chicago, USA). Percentage Sensitivity, Specificity, Positive Predictive and Negative Predictive Values for InBios, ImmuneMed and WF were 99.25, 93.02, 95.68, 98.77; 94.87, 94.19, 96.21, 92.05 and 50.38, 95.51, 94.29, 56.67 respectively. A total of 134 patients were positive in reference standard InBios IgM ELISA. This new rapid ST IgM kit validated for the first time in India, showed good sensitivity and specificity. As a Point-of-Care (PoC) test, the kit would be helpful in both urban and remote rural parts of India.
Anitharaj, Velmurugan; Pradeep, Jothimani; Park, Sungman; Kim, Seung-Han; Kim, Young Jin; Kim, Eun-Ye; Kim, Yoon-Won
2016-01-01
Introduction Scrub Typhus (ST) is being reported from different parts of India in the recent past. However, the diagnosis and confirmation of ST cases require specific serological and molecular diagnostic tests. Both rapid and conventional ELISA tests need to be properly evaluated. Aim Evaluation of a new ST IgM Immunochromatography (ICT) test kit (InBios Scrub Typhus Detect IgM Rapid Test) and compare it with another rapid kit, conventional ELISA kit and Weil-Felix (WF) test. Materials and Methods This prospective study was carried out in Mahatma Gandhi Medical College and Research Institute, Puducherry, during November 2015 to June 2016. Clinically suspected 220 ST patients were examined by a new kit, InBios Scrub Typhus Detect IgM Rapid Test, taking the conventional InBios Scrub Typhus Detect IgM ELISA as reference. Additional comparison was made with ImmuneMed Scrub Typhus Rapid, and WF test (single OXK titers ≥1:320). Statistical analysis was performed (Chi-square, Spearman’s correlation and Kappa) using IBM SPSS Statistics 17 for Windows (SPSS Inc; Chicago, USA). Results Percentage Sensitivity, Specificity, Positive Predictive and Negative Predictive Values for InBios, ImmuneMed and WF were 99.25, 93.02, 95.68, 98.77; 94.87, 94.19, 96.21, 92.05 and 50.38, 95.51, 94.29, 56.67 respectively. A total of 134 patients were positive in reference standard InBios IgM ELISA. Conclusion This new rapid ST IgM kit validated for the first time in India, showed good sensitivity and specificity. As a Point-of-Care (PoC) test, the kit would be helpful in both urban and remote rural parts of India. PMID:28050364
[Microbiology--laboratory examinations for bacterias].
Hen, Renjun; Imafuku, Yuji; Yoshida, Hiroshi
2002-11-01
As it has been required to identify pathogenic microbes in shorter times, simple and rapid methods have been developed and used. Here, we summarized the present situation of rapid diagnostic testing in clinical microbiology in Japan, and also presented our results on PBP2' detection. The rapid test kits available in Japan for E. coli, Helicobacter pylori, Salmonella, Streptococcus and Staphylococcus aureus were described. Rapid examination methods are based mainly on immunologic reactions, which included slide agglutination using latex particle, immunochromatography and ELISA. Times required for the identification are 10 to 15 minutes. Moreover, rapid test kits employing PCR are also marketed. Further, we evaluated MRSA-LA "Seiken" which is a rapid detection kit for PBP2' produced by MRSA. The test was shown to be highly sensitive and specific. For the rapid identification of pathogenic microbes, simple and rapid test kits described here will be used more in clinical diagnosis.
Immunochemical analytical methods for the determination of peanut proteins in foods.
Whitaker, Thomas B; Williams, Kristina M; Trucksess, Mary W; Slate, Andrew B
2005-01-01
Peanut proteins can cause allergenic reactions that can result in respiratory and circulatory effects in the body sometimes leading to shock and death. The determination of peanut proteins in foods by analytical methods can reduce the risk of serious reactions in the highly sensitized individual by allowing for the detection of these proteins in a food at various stages of the manufacturing process. The method performance of 4 commercially available enzyme-linked immunosorbent assay (ELISA) kits was evaluated for the detection of peanut proteins in milk chocolate, ice cream, cookies, and breakfast cereals: ELISA-TEK Peanut Protein Assay, now known as "Bio-Kit" for peanut proteins, from ELISA Technologies Inc.; Veratox for Peanut Allergens from Neogen Corp.; RIDASCREEN Peanut Kit from R-Biopharm GmbH; and ProLisa from Canadian Food Technology Ltd. The 4 test kits were evaluated for accuracy (recovery) and precision using known concentrations of peanut or peanut proteins in the 4 food matrixes. Two different techniques, incurred and spiked, were used to prepare samples with 4 known concentrations of peanut protein. Defatted peanut flour was added in the incurred samples, and water-soluble peanut proteins were added in the spiked samples. The incurred levels were 0.0, 10, 20, and 100 microg whole peanut per g food; the spiked levels were 0.0, 5, 10, and 20 microg peanut protein per g food. Performance varied by test kit, protein concentration, and food matrix. The Veratox kit had the best accuracy or lowest percent difference between measured and incurred levels of 15.7% when averaged across all incurred levels and food matrixes. Recoveries associated with the Veratox kit varied from 93 to 115% for all food matrixes except cookies. Recoveries for all kits were about 50% for cookies. The analytical precision, as measured by the variance, increased with an increase in protein concentration. However, the coefficient of variation (CV) was stable across the 4 incurred protein levels and was 7.0% when averaged across the 4 food matrixes and analytical kits. The R-Biopharm test kit had the best precision or a CV of 4.2% when averaged across all incurred levels and food matrixes. Because measured protein values varied by test kit and food matrix, a method was developed to normalize or transform measured protein concentrations to an adjusted protein value that was equal to the known protein concentration. The normalization method adjusts measured protein values to equal the true protein value regardless of the type test kit or type food matrix.
C.R. Lane; E. Hobden; L. Laurenson; V.C. Barton; K.J.D. Hughes; H. Swan; N. Boonham; A.J. Inman
2008-01-01
Plant health regulations to prevent the introduction and spread of Phytophthora ramorum and P. kernoviae require rapid, cost effective diagnostic methods for screening large numbers of plant samples at the time of inspection. Current on-site techniques require expensive equipment, considerable expertise and are not suited for plant...
NASA Astrophysics Data System (ADS)
Wang, Han; Zhang, Linfeng; Han, Jiequn; E, Weinan
2018-07-01
Recent developments in many-body potential energy representation via deep learning have brought new hopes to addressing the accuracy-versus-efficiency dilemma in molecular simulations. Here we describe DeePMD-kit, a package written in Python/C++ that has been designed to minimize the effort required to build deep learning based representation of potential energy and force field and to perform molecular dynamics. Potential applications of DeePMD-kit span from finite molecules to extended systems and from metallic systems to chemically bonded systems. DeePMD-kit is interfaced with TensorFlow, one of the most popular deep learning frameworks, making the training process highly automatic and efficient. On the other end, DeePMD-kit is interfaced with high-performance classical molecular dynamics and quantum (path-integral) molecular dynamics packages, i.e., LAMMPS and the i-PI, respectively. Thus, upon training, the potential energy and force field models can be used to perform efficient molecular simulations for different purposes. As an example of the many potential applications of the package, we use DeePMD-kit to learn the interatomic potential energy and forces of a water model using data obtained from density functional theory. We demonstrate that the resulted molecular dynamics model reproduces accurately the structural information contained in the original model.
Rohner, Fabian; Kangambèga, Marcelline O.; Khan, Noor; Kargougou, Robert; Garnier, Denis; Sanou, Ibrahima; Ouaro, Bertine D.; Petry, Nicolai; Wirth, James P.; Jooste, Pieter
2015-01-01
Background Iodine deficiency has important health and development consequences and the introduction of iodized salt as national programs has been a great public health success in the past decades. To render national salt iodization programs sustainable and ensure adequate iodization levels, simple methods to quantitatively assess whether salt is adequately iodized are required. Several methods claim to be simple and reliable, and are available on the market or are in development. Objective This work has validated the currently available quantitative rapid test kits (quantRTK) in a comparative manner for both their laboratory performance and ease of use in field settings. Methods Laboratory performance parameters (linearity, detection and quantification limit, intra- and inter-assay imprecision) were conducted on 5 quantRTK. We assessed inter-operator imprecision using salt of different quality along with the comparison of 59 salt samples from across the globe; measurements were made both in a laboratory and a field setting by technicians and non-technicians. Results from the quantRTK were compared against iodometric titration for validity. An ‘ease-of-use’ rating system was developed to identify the most suitable quantRTK for a given task. Results Most of the devices showed acceptable laboratory performance, but for some of the devices, use by non-technicians revealed poorer performance when working in a routine manner. Of the quantRTK tested, the iCheck® and I-Reader® showed most consistent performance and ease of use, and a newly developed paper-based method (saltPAD) holds promise if further developed. Conclusions User- and field-friendly devices are now available and the most appropriate quantRTK can be selected depending on the number of samples and the budget available. PMID:26401655
Orbital Maneuvering Vehicle (OMV) remote servicing kit
NASA Technical Reports Server (NTRS)
Brown, Norman S.
1988-01-01
With the design and development of the Orbital Maneuvering Vehicle (OMV) progressing toward an early 1990 initial operating capability (IOC), a new era in remote space operations will evolve. The logical progression to OMV front end kits would make available in situ satellite servicing, repair, and consummables resupply to the satellite community. Several conceptual design study efforts are defining representative kits (propellant tanks, debris recovery, module servicers); additional focus must also be placed on an efficient combination module servicer and consummables resupply kit. A remote servicer kit of this type would be designed to perform many of the early maintenance/resupply tasks in both nominal and high inclination orbits. The kit would have the capability to exchange Orbital Replacement Units (ORUs), exchange propellant tanks, and/or connect fluid transfer umbilicals. Necessary transportation system functions/support could be provided by interfaces with the OMV, Shuttle (STS), or Expendable Launch Vehicle (ELV). Specific remote servicer kit designs, as well as ground and flight demonstrations of servicer technology are necessary to prepare for the potential overwhelming need. Ground test plans should adhere to the component/system/breadboard test philosophy to assure maximum capability of one-g testing. The flight demonstration(s) would most likely be a short duration, Shuttle-bay experiment to validate servicer components requiring a micro-g environment.
Keating, Glenda; Bliwise, Donald L; Saini, Prabhjyot; Rye, David B; Trotti, Lynn Marie
2017-09-01
The hypothalamic peptide hypocretin 1 (orexin A) may be assayed in cerebrospinal fluid to diagnose narcolepsy type 1. This testing is not commercially available, and factors contributing to assay variability have not previously been comprehensively explored. In the present study, cerebrospinal fluid hypocretin concentrations were determined in duplicate in 155 patient samples, across a range of sleep disorders. Intra-assay variability of these measures was analyzed. Inter-assay correlation between samples tested at Emory and at Stanford was high (r = 0.79, p < 0.0001). Intra-assay correlation between samples tested in duplicate in our center was also high (r = 0.88, p < 0.0001); intra-assay variability, expressed as the difference between values as a percentage of the higher value, was low at 9.4% (SD = 7.9%). Although both time the sample spent in the freezer (r = 0.16, p = 0.04) and age of the kit used for assay (t = 3.64, p = 0.0004) were significant predictors of intra-kit variability in univariate analyses, only age of kit was significant in multivariate linear regression (F = 4.93, p = 0.03). Age of radioimmunoassay kit affects intra-kit variability of measured hypocretin values, such that kits closer to expiration exhibit significantly more variability.
DEMONSTRATION BULLETIN: ENVIROGARD™ PCB TEST KIT - MILLIPORE, INC.
The EnviroGard™ polychlorinated biphenyl (PCB) immunoassay test kit rapidly analyzes for PCB concentrations in soils. Soil sample extracts are added to test tubes coated with antibodies that bind PCB molecules. The excess soil extracts are washed out of the tubes after incubat...
NASA Technical Reports Server (NTRS)
Hankins, D. B.; Wake, W. H.
1981-01-01
The potential remote sensing user community is enormous, and the teaching and training tasks are even larger; however, some underlying principles may be synthesized and applied at all levels from elementary school children to sophisticated and knowledgeable adults. The basic rules applying to each of the six major elements of any training course and the underlying principle involved in each rule are summarized. The six identified major elements are: (1) field sites for problems and practice; (2) lectures and inside study; (3) learning materials and resources (the kit); (4) the field experience; (5) laboratory sessions; and (6) testing and evaluation.
Multiplex method for initial complex testing of antibodies to blood transmitted diseases agents.
Poltavchenko, Alexander G; Nechitaylo, Oleg V; Filatov, Pavel V; Ersh, Anna V; Gureyev, Vadim N
2016-10-01
Initial screening of donors and population at high risk of infection with blood transmitted diseases involves a number of analyses using monospesific diagnostic systems, and therefore is expensive labor- and time-consuming process. The goal of this work is to construct a multiplex test enabling to carry out rapid initial complex testing at a low price. The paper describes a kit making it possible to detect simultaneously antibodies to six agents of the most significant blood transmitted diseases: HIV virus, hepatitis B and C viruses, cytomegalovirus, T. pallidum and T. gondii in blood products. The kit comprises multiplex dot-immunoassay based on plane protein arrays (immune chips) using colloidal gold conjugates and silver development. It provides an opportunity to carry out complex analysis within 70min at room temperature, and there is no need of well-qualified personnel. We compared laboratory findings of the kit with monospecific kits for ELISA produced by two Russian commercial companies. Dot-assay results correlate well with data obtained using commercial kits for ELISA. Furthermore, multiplex analysis is quicker and cheaper in comparison with ELISA and can be carried out in non-laboratory conditions. The kit for multiplex dot-immunoassay of antibodies to blood transmitted agents can significantly simplify initial complex testing. Copyright © 2016 Elsevier B.V. All rights reserved.
Ha, Tam Cam; Yong, Sook Kwin; Yeoh, Kheng-Wei; Kamberakis, Kay; Yeo, Richard Ming Chert; Koh, Gerald Choon-Huat
2014-11-01
The purpose of the study was to investigate whether fecal occult blood test (FOBT) home-delivery and individual education or combined with family education increases FOBT uptake rates in Singapore. This is a randomized controlled intervention study of Singaporean residents aged 50 years and above, conducted in May 2012 till May 2013. Eligible individuals in randomly selected households were screened, and one member was randomly selected and allocated to one of the four arms: Group A (individual and family education, FOBT kits provided), Group B (individual education only, FOBT kits provided), Group C (no education, FOBT kits provided) and Group D (no education or FOBT kits provided). Overall response rate was 74.7 %. The FOBT return rates for groups A, B, C and D were 24.5 % [CI 16.2-34.4 %], 25.3 % [CI 16.4-36.0 %], 10.7 % [CI 4.7-19.9 %] and 2.2 % [CI 0.3-7.7 %], respectively. Respondents who were provided education and home-delivered FOBT kits were 15 times more likely to return FOBT kits [Group A: OR 15.0 (3.4-66.2); Group B: OR 15.5 (3.5-68.8)] and those provided with home-delivered FOBT without education were five times more likely to return FOBT kits [Group C: OR 5.8 (1.2-28.3)] than those without education and FOBT kits (Group D). There was no significant difference in return of FOBT kits whether education was provided to subject with or without a family member. Home delivery of FOBT kits increased FOBT return rates and individual education combined with home-delivered FOBT increased FOBT return rates even further. However, additional combination with family education did not increase FOBT rates further.
Trouvay, Mélanie; Palazon, Georges; Berger, Franck; Volney, Béatrice; Blanchet, Denis; Faway, Emilie; Donato, Damien; Legrand, Eric; Carme, Bernard; Musset, Lise
2013-01-01
Care for malaria patients in endemic areas has been improved through the increasing use of Rapid Diagnostic Tests (RDTs). Most RDTs target the histidine-rich protein-2 antigen (PfHRP2) to detect P. falciparum, as it is abundant and shows great heat stability. However, their use in South America has been widely questioned following a recent publication that pinpoints the high prevalence of Peruvian field isolates lacking the gene encoding this protein. In the remote rural health centers of French Guiana, RDTs are the main diagnosis tools. Therefore, a study of PfHRP2 RDT performances and pfhrp2 genotyping was conducted to determine whether a replacement of the current pLDH-based kit could be considered. The performance study compared the SD Malaria Ag test P.f/Pan® kit with the current gold standard diagnosis by microscopy. The prevalence of pfhrp2 and pfhrp3 deletions were evaluated from 221 P. falciparum isolates collected between 2009 and 2011 in French Guiana. Between January 2010 and August 2011, 960 suspected cases of malaria were analyzed using microscopy and RDTs. The sensitivity of the SD Malaria Ag test P.f/Pan® for detection of P. falciparum was 96.8% (95% CI: 90.9-99.3), and 86.0% (95% CI: 78.9-91.5) for the detection of P. vivax. No isolates (95% CI: 0-4.5) lacking either exon of the pfhrp2 gene were identified among the 221 P. falciparum isolates analyzed, but 7.4% (95% CI: 2.8-15.4) lacked the exon 2 part of the pfhrp3 gene. Field isolates lacking either exon of the pfhrp2 gene are absent in this western part of South America. Despite its sensibility to detect P. vivax, the SD Malaria Ag test P.f/Pan® kit is a satisfying alternative to microscopy in remote health centers, where it is difficult to provide highly skilled microscopists and to maintain the necessary equipment.
[Comparison of Dengue viral nonstructural protein 1 antigen testing kits].
Wu, D; Zhao, L Z; Wu, Y H; Zhang, H; Zhang, M; Tan, Q Q; Zhou, H Q; Zhang, F C; He, J F
2018-02-06
Objective: To investigate the sensitivity and specificity of commercial nonstructural protein 1 (NS1) testing kits for Dengue fever diagnose, and provide the evidence for diagnostic criteria revision. Methods: 300 PCR or virus isolation positive blood samples for dengue virus were collected from sentinel hospitals for dengue surveillance in Guangzhou, Dongguang and Zhongshang from May 2015 to Nov. 2016. At the same time, 308 PCR negative samples for Dengue virus were collected as control group. The information of the sample was collected using questionnaires. These samples were tested using imported and domestic ELISA and the colloidal gold-labeled kits that were widely used for detecting dengue NS1. Sensitivity, specificity and coincidence were calculated and analyzed, and Z hongshan's result was regarded as the reslut of the third part. Results: The positive group includes 133 males and 167 females, average ages are 47.2±13.3, 179, 110 and 11 of them is Dengue Ⅰ, Ⅱ and Ⅲ respectively. The negative group includes 154 males and 154 females, average ages are (40.1±11.6) years old. The sensitivity of domestic ELISA Kits (94.5%) is less than imported (99.5%), and the result has statistical significance (χ(2)=8.59, P= 0.030), the specificity is 99.7% and 97.7% respectively; The sensitivity of imported and domestic the colloidal gold-labeled Kits is 97.5% and 96.5% respectively, both of specificities are 100%. The sensitivity and specificity of Dengue Ⅰ for NS1 test are more than 97.0%. The sensitivity of domestic ELISA and gold-labeled Kits is 90.0% and 95.0%, and the specificity is 96.8% and 100% respectively for Dengue Ⅱ test. The sensitivity of imported ELISA and gold-labeled Kits is 100% and 98.0%, and the specificity is 99.4% and 100% respectively for Dengue Ⅱ test. The result of the third party show the sensitivity and specificity of domestic ELISA and gold-labeled Kits are 90.0% and 98.0%, the differences has statistical significance (χ(2)=5.67, P= 0.020). Conclusion: NS1 testing can be used as early dengue fever diagnose for higher sensitivity and specificity.
Take a Field Trip through the 1980s. Celebrate the Century Education Series.
ERIC Educational Resources Information Center
Postal Service, Washington, DC.
This is one in a series of six kits that the U.S. Postal Service (USPS) is publishing to help teach through stamps the history of the 20th century and the people, places, and events that have shaped our nation during the past 100 years. Each kit is designed to be taught as a complete and independent unit. The kit, which focuses on the 1980s,…
Evaluation of commercial kits for dual extraction of DNA and RNA from human body fluids.
Schweighardt, Andrew J; Tate, Courtney M; Scott, Kristina A; Harper, Kathryn A; Robertson, James M
2015-01-01
STR typing of DNA evidence can identify the donor with a high power of discrimination but cannot identify the tissue origin of a body-fluid stain. Using RNA to attribute a crime scene stain to a particular tissue may aid in reconstruction efforts. With blood from 10 donors, four DNA and RNA coextraction kits were evaluated by measuring yields and STR and mRNA profiles. T tests indicated some significant differences in kit performance. The Zymo Research ZR-Duet(™) kit performed best based on average DNA (41.4 ng) and mRNA (4.07 ng) yields and was the only kit to provide complete DNA/RNA profiles for all samples. The consistency of this kit was challenged by data from additional blood and saliva donors. Further testing is advised before a superior kit is unequivocally chosen. Stand-alone DNA or RNA purification generally offers higher yield, but coextraction may still allow successful STR profiling and tissue source identification. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.
Garcia, L S; Shimizu, R Y
1997-01-01
It is well known that Giardia lamblia and Cryptosporidium parvum can cause severe symptoms in humans, particularly those who are immunologically compromised. Immunoassay procedures offer both increased sensitivity and specificity compared to conventional staining methods. These reagents are also helpful when screening large numbers of patients, particularly in an outbreak situation or when screening patients with minimal symptoms. The data obtained by using 9 diagnostic kits were compared: direct fluorescent-antibody assay (DFA) kits (TechLab Giardia/Crypto IF kit, TechLab Crypto IF kit, and Meridian Merifluor Cryptosporidium/Giardia) and enzyme immunoassay (EIA) kits (Alexon ProSpecT Giardia EZ Microplate Assay, Alexon ProSpecT Cryptosporidium Microplate Assay, Cambridge Giardia lamblia Antigen Microwell ELISA, Meridian Premier Giardia lamblia, Meridian Premier Cryptosporidium, TechLab Giardia CELISA, Trend Giardia lamblia EIA). The test with the Meridian Merifluor Cryptosporidium/Giardia kit was used as the reference method. In various combinations, 60 specimens positive for Giardia, 60 specimens positive for Cryptosporidium, 40 specimens positive for a Giardia-Cryptosporidium mix, and 50 negative fecal specimens were tested. Different species (nine protozoa, three coccidia, one microsporidium, five nematodes, three cestodes, and one trematode) were included in the negative specimens. The sensitivity of EIA for Giardia ranged from 94% (Alexon) to 99% (Trend and Cambridge); the specificity was 100% with all EIA kits tested. The sensitivity of EIA for Cryptosporidium ranged from 98% (Alexon) to 99% (Meridian Premier); specificities were 100%. All DFA results were in agreement, with 100% sensitivity and specificity; however, the TechLab reagents resulted in fluorescence intensity that was generally one level below that seen with the reagents used in the reference method. In addition to sensitivity and specificity, factors such as cost, simplicity, ease of interpretation of results (color, intensity of fluorescence), equipment, available personnel, and number of tests ordered are also important considerations prior to kit selection. PMID:9163474
Johnny Horizon Environmental Test Kit.
ERIC Educational Resources Information Center
Bentley, Richard; Bentley, William
Derived from tests presently used by state and federal agencies involved with pollution detection, this Environmental Test Kit contains materials and instructions for ten experiments. Each experiment is designed to test a different aspect of air and water, to find out whether or not the air and water in the tester's immediate area has been…
Evaluating 6 ricin field detection assays.
Slotved, Hans-Christian; Sparding, Nadja; Tanassi, Julia Tanas; Steenhard, Nina R; Heegaard, Niels H H
2014-01-01
This study presents data showing the performance of 6 commercial detection assays against ricin around concentrations specified as detection limits by the producers. A 2-fold dilution series of 20 ng/ml ricin was prepared and used for testing the lateral-flow kits: BADD, Pro Strips™, ENVI, RAID DX, Ricin BioThreat Alert, and IMASS™ device. Three of the 6 tested field assays (IMASS™ device, ENVI assay, and the BioThreat Alert assay) were able to detect ricin, although differences in the measured detection limits compared to the official detection limits and false-negative results were observed. We were not able to get the BADD, Pro Strips™, and RAID assays to function in our laboratory. We conclude that when purchasing a field responder assay, there is large variation in the specificity of the assays, and a number of in-house tests must be performed to ensure functionality.
Mohammadi, M; Talebkhan, Y; Khalili, G; Mahboudi, F; Massarrat, S; Zamaninia, L; Oghalaei, A
2008-01-01
To evaluate a home-made ELISA kit for detection of Helicobacter pylori (Hp) infection and comparison of its immunologic criteria with those of foreign commercial kits. A home-made IgG ELISA kit was developed using soluble antigenic fractions of Hp proteins. Confirmed sera were tested and serological criteria were evaluated through assessment of 199 serum samples. The accuracy, sensitivity and specificity values of home-made kit were 92, 92 and 90.4%, respectively. These immunologic criteria for Trinity kit were 95.2, 95.2 and 95% in comparison with IBL kit (91.3, 92.2 and 88.5%), BIOHIT kit (72.4, 41.6 and 94.1%) and HelicoBlot2.1 (94.2, 93.4 and 100%). Kappa agreement assessment demonstrated that two of the imported ELISA kits had fair to moderate agreement with the home-made kit while the other one had a poor agreement value. Apart from comparable values between the home-made kit and the most efficient imported kit (Trinity) there was significant cost benefit. Therefore, we recommend the home-made kit as a suitable substitution for detection of Hp infection in the Iranian population.
Yunus, Muhammad Hafiznur; Tan Farrizam, Siti Naqiuyah; Abdul Karim, Izzati Zahidah; Noordin, Rahmah
2018-01-01
Laboratory diagnosis of toxocariasis is still a challenge especially in developing endemic countries with polyparasitism. In this study, three Toxocara canis recombinant antigens, rTES-26, rTES-30, and rTES-120, were expressed and used to prepare lateral flow immunoglobulin G4 (IgG4) dipsticks. The concordance of the results of the rapid test (comprising three dipsticks) with a commercial IgG-enzyme-linked immunosorbent assay (ELISA) (Cypress Diagnostics, Belgium) was compared against the concordance of two other commercial IgG-ELISA kits (Bordier, Switzerland and NovaTec, Germany) with the Cypress kit. Using Toxocara- positive samples, the concordance of the dipstick dotted with rTES-26, rTES-30, and rTES-120 was 41.4% (12/29), 51.7% (15/29), and 72.4% (21/29), respectively. When positivity with any dipstick was considered as an overall positive rapid test result, the concordance with the Cypress kit was 93% (27/29). Meanwhile, when compared with the results of the Cypress kit, the concordance of IgG-ELISA from NovaTec and Bordier was 100% (29/29) and 89.7% (26/29), respectively. Specific IgG4 has been recognized as a marker of active infection for several helminthic diseases; therefore, the two non-concordant results of the rapid test when compared with the NovaTec IgG-ELISA kit may be from samples of people with non-active infection. All the three dipsticks showed 100% (50/50) concordance with the Cypress kit when tested with serum from individuals who were healthy and with other infections. In conclusion, the lateral flow rapid test is potentially a good, fast, and easy test for toxocariasis. Next, further validation studies and development of a test with the three antigens in one dipstick will be performed.
21 CFR 864.1860 - Immunohistochemistry reagents and kits.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Immunohistochemistry reagents and kits. (a) Identification. Immunohistochemistry test systems (IHC's) are in vitro... performance claims, which may be packaged with ancillary reagents in kits. Their intended use is to identify, by immunological techniques, antigens in tissues or cytologic specimens. Similar devices intended for...
21 CFR 864.1860 - Immunohistochemistry reagents and kits.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Immunohistochemistry reagents and kits. (a) Identification. Immunohistochemistry test systems (IHC's) are in vitro... performance claims, which may be packaged with ancillary reagents in kits. Their intended use is to identify, by immunological techniques, antigens in tissues or cytologic specimens. Similar devices intended for...
Feberwee, A; Mekkes, D R; de Wit, J J; Hartman, E G; Pijpers, A
2005-06-01
In this study, the technical performance of culture, two commercially available polymerase chain reaction (PCR) tests, rapid plate agglutination (RPA) test, hemagglutination inhibition (HI) test, and eight commercially available enzyme-linked immunosorbent assays (ELISAs) were compared for the detection of avian mycoplasma infections from 3 days postinfection (d.p.i.) through 35 d.p.i. The tests were carried out on samples from specified pathogen-free layers that were infected at 66 wk of age with recent Mycoplasma synoviae (MS) and Mycoplasma gallisepticum (MG) field strains, MS and MG ATCC strains, and Mycoplasma imitans (MIM), respectively. Results showed a high percentage of positive samples in the homologous infected groups and a high percentage of negative samples (100%) in the uninfected and heterologous infected groups during 35 d.p.i. of both culture and PCR tests. For the group infected with the MG 15302 ATCC strain, serology was more sensitive than bacteriology. All MG and MS tests, with the exception of MG ELISA kit D showed a lower percentage of positive samples during 35 d.p.i. for the detection of the MG and MS ATCC strain infection compared with that of the field strains. Also, the number of cross-reactions (false positives) in the serologic tests was lower after infection with an ATCC strain than after an infection with the MG or MS field strain. Contradictory to other studies, the ELISAs and the RPA test using undiluted serum showed a relatively high number of false-positive results. The MG ELISAs (except ELISA kit D) showed more false-positive results (up to 37%) in the MIM-infected group than in the MS-infected groups. This was not unexpected, as MIM and MG have a close antigenic relationship. The results of the serologic tests in this study showed that a certain level of false-positive results can be expected in about any serologic test. Although the level of false-positive results varied between several serologic tests, this study showed that it is not advisable to rely completely on one test (system) only.
Westman, Mark E; Malik, Richard; Hall, Evelyn; Sheehy, Paul A; Norris, Jacqueline M
2015-10-01
This study challenges the commonly held view that the feline immunodeficiency virus (FIV) infection status of FIV-vaccinated cats cannot be determined using point-of-care antibody test kits due to indistinguishable antibody production in FIV-vaccinated and naturally FIV-infected cats. The performance of three commercially available point-of-care antibody test kits was compared in a mixed population of FIV-vaccinated (n=119) and FIV-unvaccinated (n=239) cats in Australia. FIV infection status was assigned by considering the results of all antibody kits in concert with results from a commercially available PCR assay (FIV RealPCR™). Two lateral flow immunochromatography test kits (Witness FeLV/FIV; Anigen Rapid FIV/FeLV) had excellent overall sensitivity (100%; 100%) and specificity (98%; 100%) and could discern the true FIV infection status of cats, irrespective of FIV vaccination history. The lateral flow ELISA test kit (SNAP FIV/FeLV Combo) could not determine if antibodies detected were due to previous FIV vaccination, natural FIV infection, or both. The sensitivity and specificity of FIV RealPCR™ for detection of viral and proviral nucleic acid was 92% and 99%, respectively. These results will potentially change the way veterinary practitioners screen for FIV in jurisdictions where FIV vaccination is practiced, especially in shelter scenarios where the feasibility of mass screening is impacted by the cost of testing. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
DEMONSTRATION AND QUALITY ASSURANCE PROJECT ...
The demonstration of technologies for determining the presence of dioxin in soil and sediment is being conducted under the U.S. Environmental Protection Agency Superfund Innovative Technology Evaluation Program in Saginaw, Michigan, at Green Point Environmental Learning Center from approximately April 26 to May 6, 2004. The primary purpose of the demonstration is to evaluate innovative monitoring technologies. The technologies listed below will be demonstrated. .AhRC PCRTM Kit, Hybrizyme Corporation .Ah-IMMUNOASSY@ Kit, Paralsian, Inc. .Coplanar PCB Immunoassay Kit, Abraxis LLC .DF-l Dioxin/Furan Immunoassay Kit, CAPE Technologies L.L.C. .CALUX@ by Xenobiotic Detection Systems, Inc- .Dioxin ELISA Kit, Wako Pure Chemical Industries LTD. This demonstration plan describes the procedures that will be used to verify the performance and cost of these technologies. The plan incorporates the quality assurance and quality control elements needed to generate data of sufficient quality to document each technology's performance and cost. A separate innovative technology verification report (ITVR) will.be prepared for each technology. The ITVRs will present the demonstration findings associated with the demonstration objectives. The objective of this program is to promote the acceptance and use of innovative field technologies by providing well-documented performance and cost data obtained from field demonstrations.
Enzymatic test kits, generally designed to be handheld and portable, detect the presence of chemical agents, carbamate pesticides, and/or organophosphate pesticides by relying on the reaction of the cholinesterase enzyme. Under normal conditions, the enzyme reacts as expected wi...
Using technology to support HIV self-testing among MSM.
LeGrand, Sara; Muessig, Kathryn E; Horvath, Keith J; Rosengren, Anna L; Hightow-Weidman, Lisa B
2017-09-01
Technology-based HIV self-testing (HST) interventions have the potential to improve access to HIV testing among gay, bisexual, and other MSM, as well as address concerns about HST use, including challenges with linkage to appropriate follow-up services. This review examines studies that use technology-based platforms to increase or improve the experience of HST among MSM. Seven published studies and eight funded studies were included in this review. Comprehensive prevention interventions with free HST kit distribution and interventions that provide free HST kits and support the HST process address a greater number of barriers (e.g., access, correct use of testing kits, and correct interpretation of results) than studies that only distribute free HST kits through technology-based platforms. By addressing HIV-testing barriers and specific HST concerns, these interventions address a critical need to improve first time and repeat testing rates among MSM. Additional research is needed to determine the efficacy of recent formative HST interventions. If proven efficacious, scale-up of these strategies have the potential to increase HIV testing among MSM via expanded HST uptake.
NASA Technical Reports Server (NTRS)
Gazda, Daniel B.; Nolan, Daniel J.; Rutz, Jeffrey A.; Shcultz, John R.; Siperko, Lorraine M.; Porter, Marc D,; Lipert, Robert J.; Limardo, Jose G.; McCoy, J. Torin
2009-01-01
Scientists and engineers from the Wyle Integrated Science and Engineering Group are working with researchers at the University of Utah and Iowa State University to develop and certify an experimental water quality monitoring kit based on Colorimetric Solid Phase Extraction (CSPE). The kit will be launched as a Station Development Test Objective (SDTO) experiment and evaluated on the International Space Station (ISS) to determine the acceptability of CSPE technology for routine inflight water quality monitoring. Iodine and silver, the biocides used in the US and Russian on-orbit water systems, will serve as test analytes for the technology evaluation. This manuscript provides an overview of the CSPE SDTO experiment and details the development and certification of the experimental water quality monitoring kit. Initial results from reagent and standard solution stability testing and environmental testing performed on the kit hardware are also reported.
Home bowel cancer tests and informed choice--is current information sufficient?
Howard, K; Salkeld, G
2003-10-01
To evaluate the type of information that is available to purchasers of home-based bowel cancer test kits. Manufacturers, pharmacies and independent testing programs were contacted to obtain faecal occult blood test (FOBT) kits. State cancer organisations were contacted for information on bowel cancer screening. Information on bowel cancer, the FOBT kit, the testing process and potential benefits and harms of the screening process were assessed using guidelines provided by the UK General Medical Council (GMC). FOBT kits and cancer organisation information provided adequate information on the purpose of screening, the screening process itself and potential benefits, but provided no information concerning uncertainties of screening or potential harms. On the basis of both the UK GMC criteria and patient desires for information, the information available at present falls short of being considered adequate for an informed decision to purchase a home-based FOBT. We must ensure adequate and balanced information is available to redress the present information asymmetry to facilitate informed participation in a potentially valuable public health initiative.
Škereňová, Markéta; Mikulová, Veronika; Čapoun, Otakar; Zima, Tomáš
2016-01-01
Nowadays, on-a-chip capillary electrophoresis is a routine method for the detection of PCR fragments. The Agilent 2100 Bioanalyzer was one of the first commercial devices in this field. Our project was designed to study the characteristics of Agilent DNA 1000 kit in PCR fragment analysis as a part of circulating tumour cell (CTC) detection technique. Despite the common use of this kit a complex analysis of the results from a long-term project is still missing. A commercially available Agilent DNA 1000 kit was used as a final step in the CTC detection (AdnaTest) for the determination of the presence of PCR fragments generated by Multiplex PCR. Data from 30 prostate cancer patients obtained during two years of research were analyzed to determine the trueness and precision of the PCR fragment size determination. Additional experiments were performed to demonstrate the precision (repeatability, reproducibility) and robustness of PCR fragment concentration determination. The trueness and precision of the size determination was below 3% and 2% respectively. The repeatability of the concentration determination was below 15%. The difference in concentration determination increases when Multiplex-PCR/storage step is added between the two measurements of one sample. The characteristics established in our study are in concordance with the manufacturer's specifications established for a ladder as a sample. However, the concentration determination may vary depending on chip preparation, sample storage and concentration. The 15% variation of concentration determination repeatability was shown to be partly proportional and can be suppressed by proper normalization.
STS-5 Columbia, OV-102, middeck documentation
NASA Technical Reports Server (NTRS)
1982-01-01
Items stowed temporarily on forward middeck lockers include (left to right) field sequential (FS) crew cabin camera, procedural notebook, communications kit assembly (assy) headset (HDST) interface unit (HIU), personal hygiene kit, personal hygiene mirror assy, meal tray assemblies, towels, and Vestibular Study Experiment headset and antenna.
Field analysis for explosives: TNT and RDX
DOE Office of Scientific and Technical Information (OSTI.GOV)
Elcoate, W.; Mapes, J.
The EPA has listed as hazardous many of the compounds used in the production of ammunitions and other explosive ordnance. The contamination of soil with TNT (2,4,6-trinitrotoluene), the major component of many munitions formulations and to a lesser degree RDX (hexhydro-1,3,5-trinitro-1,3,5-trizine) is a significant problem at many ammunition manufacturing facilities, depots, and ordnance disposal sites. Field test kits for explosives TNT and RDX (hexhydro-1,3,5-trinitro-1,3,5-triazine) were developed based on the methods of T.F. Jenkins and M.E. Walsh and T.F Jenkins. EnSys Environmental Products, Inc. with technical support from T.F. Jenkins took the original TNT procedure, modified it for easier field use,more » performed validation studies to ensure that it met or exceeded the method specifications for both the T.F. Jenkins and SW-846 methods, and developed an easy to use test format for the field testing of TNT. The RDX procedure has gone through the development cycle and is presently in the field validation phase. This paper describes the test protocol and performance characteristics of the TNT test procedure.« less
Raj, G Dhinakar; Thiagarajan, V; Nachimuthu, K
2007-09-01
A simple, user-friendly, and rapid method to detect the presence of antibodies to egg drop syndrome 76 (EDS) virus in chicken sera based on an immunofiltration (flow-through) test was developed. Purified EDS virus antigen was coated onto nitrocellulose membranes housed in a plastic module with layers of absorbent filter pads underneath. Following addition of serum to be tested and washing, monoclonal antibodies or polyclonal serum to chicken immunoglobulin G (IgG) was used as a bridge antibody to mediate binding between EDS virus-specific IgG and protein A gold conjugate. The appearance of a pink dot indicated the presence of antibodies to EDS virus in the sample tested. The results could be obtained within 5-10 min. The developed immunofiltration test could detect antibodies in the sera of experimentally vaccinated chickens from 2 wk postvaccination. With field sera samples, this test was positive in samples having hemagglutination inhibition titers of 8 and above. This test has the potential to be used as a field-based kit to assess seroconversion in EDS-vaccinated flocks.
DETAIL VIEW OF ELECTRONICS TEST AREA, FLIGHT KITS FACILITY, ROOM ...
DETAIL VIEW OF ELECTRONICS TEST AREA, FLIGHT KITS FACILITY, ROOM NO. 1N12, FACING WEST - Cape Canaveral Air Force Station, Launch Complex 39, Vehicle Assembly Building, VAB Road, East of Kennedy Parkway North, Cape Canaveral, Brevard County, FL
Ranjan, Rakesh; Narnaware, Shirish D; Nath, Kashi; Sawal, R K; Patil, N V
2018-04-01
Accurate early antemortem diagnosis of tuberculosis in dromedary camels is difficult due to the lack of reliable diagnostic test. The present study aimed to evaluate a lateral flow assay-based kit (rapid assay kit) in tuberculosis diagnosis that employs immuno-chromatographic detection of antibodies in serum, plasma, or whole blood. In a dromedary camel herd comprising 337 animals located at Bikaner, Rajasthan, India, 50 adult weak camels (11 males and 39 females) were tested by applying a single intradermal tuberculin test (SIDT) and rapid assay kit. A total of 14 animals (2 males, 12 females) were found positive in rapid assay. In SIDT, four animals revealed a positive reaction in the neck region and seven animals in the tail base. Another male animal was found SIDT positive but negative in rapid assay; it died after 12 months. Nine rapid assay positive animals died asymptomatically in 1- to 11-month period revealing postmortem tuberculosis lesions that were confirmed by Ziehl-Neelsen staining and histopathology. No tuberculous lesion was evident in the animal found positive in SIDT alone. Results of the present study indicated that serological tests like rapid assay kit can serve as a reliable test for antemortem diagnosis of tuberculosis in dromedary camel.
Iqbal, H. Syed; Solomon, Suniti; Murugavel, K. G.; Solomon, Sunil Suhas; Balakrishnan, P.
2005-01-01
Diagnosis of human immunodeficiency virus (HIV) infection is important for patient management and prevention of new infections. The number of test kits available for the detection of HIV antibodies is unprecedented. In order to identify appropriate test kits, we evaluated a variety of commercial kits manufactured abroad as well as in India. The plasma and serum specimens (n = 264) were collected from individuals attending the Voluntary Counseling and Testing Centre at the YRG Centre for AIDS and Education. The specimens were used to evaluate six commercially available HIV test kits: Enzaids HIV 1+2, HIV-CheX, Murex HIV-1.2.0, Genscreen HIV 1/2 version 2, Vironostika HIV Uni-Form II Ag/Ab, and CombAids RS Advantage. High sensitivities and specificities (≥99%) were observed for the Enzaids, Murex, Vironostika, and CombAids assays. HIV-CheX showed the highest number of false-positive and false-negative results. The Genscreen test also gave many false positives. The study indicated that the Enzaids, Murex, and Vironostika enzyme-linked immunosorbent assay kits and the CombAids RS Advantage rapid assay could be used to achieve acceptable results for the detection of HIV antibodies. A combination of two tests is recommended to optimize the efficiency of HIV antibody testing algorithms, especially when evaluation with an HIV Western blot confirmatory test is not possible. PMID:16339066
Antonescu, Cristina R; Viale, Agnes; Sarran, Lisa; Tschernyavsky, Sylvia J; Gonen, Mithat; Segal, Neil H; Maki, Robert G; Socci, Nicholas D; DeMatteo, Ronald P; Besmer, Peter
2004-05-15
Gastrointestinal stromal tumors (GISTs) are specific KIT expressing and KIT-signaling driven mesenchymal tumors of the human digestive tract, many of which have KIT-activating mutations. Previous studies have found a relatively homogeneous gene expression profile in GIST, as compared with other histological types of sarcomas. Transcriptional heterogeneity within clinically or molecularly defined subsets of GISTs has not been previously reported. We tested the hypothesis that the gene expression profile in GISTs might be related to KIT genotype and possibly to other clinicopathological factors. An HG-U133A Affymetrix chip (22,000 genes) platform was used to determine the variability of gene expression in 28 KIT-expressing GIST samples from 24 patients. A control group of six intra-abdominal leiomyosarcomas was also included for comparison. Statistical analyses (t tests) were performed to identify discriminatory gene lists among various GIST subgroups. The levels of expression of various GIST subsets were also linked to a modified version of the growth factor/KIT signaling pathway to analyze differences at various steps in signal transduction. Genes involved in KIT signaling were differentially expressed among wild-type and mutant GISTs. High gene expression of potential drug targets, such as VEGF, MCSF, and BCL2 in the wild-type group, and Mesothelin in exon 9 GISTs were found. There was a striking difference in gene expression between stomach and small bowel GISTs. This finding was validated in four separate tumors, two gastric and two intestinal, from a patient with familial GIST with a germ-line KIT W557R substitution. GISTs have heterogeneous gene expression depending on KIT genotype and tumor location, which is seen at both the genomic level and the KIT signaling pathway in particular. These findings may explain their variable clinical behavior and response to therapy.
Cross-reactions of reagents from streptococcal grouping kits with Streptococcus porcinus.
Thompson, T; Facklam, R
1997-01-01
Streptococcus porcinus is usually associated with swine. Because we have received several isolates from human sources that had cross-reacted with commercial group B streptococcal reagents, we examined several commercial kits to determine the extent of this cross-reaction. Fifteen reference and 15 clinical strains of S. porcinus were tested for cross-reactions with group B streptococcal reagents from 12 different commercial kits. Cross-reactions were detected with all group B reagents, but the number of cross-reactions varied with each kit. We recommend that manufacturers of reagents designed to identify group B streptococci by serologic methods test their reagents for cross-reactions with selected S. porcinus cultures or antigens. PMID:9196216
ERIC Educational Resources Information Center
Canadian Health Libraries Association.
Nine Canadian health libraries participated in a pilot test of the Benchmarking Tool Kit between January and April, 1998. Although the Tool Kit was designed specifically for health libraries, the content and approach are useful to other types of libraries as well. Used to its full potential, benchmarking can provide a common measuring stick to…
30 CFR 7.405 - Critical characteristics.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Cable Splice Kits § 7.405 Critical characteristics. (a) A sample from each production run, batch, or lot of manufactured electric cable, signaling cable, or splice made from a splice kit shall be flame... cable or splice and a sample of the cable or splice kit assembly shall be visually inspected or tested...
30 CFR 7.405 - Critical characteristics.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Cable Splice Kits § 7.405 Critical characteristics. (a) A sample from each production run, batch, or lot of manufactured electric cable, signaling cable, or splice made from a splice kit shall be flame... cable or splice and a sample of the cable or splice kit assembly shall be visually inspected or tested...
Lead Paint Test Kits Workshop: Summary Report
The U.S. Environmental Protection Agency's (EPA) Office of Research and Development (ORD) designed and conducted the Lead Paint Test Kits Workshop on October 19 and 20, 2006, at the Environmental Protection Agency's Research Triangle Park, NC campus. The workshop was conducted as...
The use of a newspaper insertion to promote DIY testing of vision in India.
Murthy, G V; Gupta, S K; Dada, V K; Pant, T D; Savita, C; Sanga, L; Neena, J
2001-08-01
The mass media have the potential to motivate people to participate in self appraisal of their own health status. An innovative communication package was designed to help people to examine vision at home. The impact of publishing the "do it yourself" (DIY) kit in Indian newspapers was evaluated. A pretested bilingual vision testing kit was published in three newspapers. The kit comprised four tumbling Es corresponding to 6/12 line of Snellen's optotypes. Directions on using the kit were enclosed. 3 -7 days after publication of the kit, a telephone survey of newspaper readers was undertaken to evaluate the impact and cost effectiveness. 603 people were contacted over the telephone. 125 (20.73%) subscribed to the newspaper carrying the DIY insertion. 43.2% (54) noticed the insertion of which 88.89% (48) read the enclosed instructions carefully. 58.33% respondents felt sufficiently motivated to contact an ophthalmologist. Graduates had a 3.83 times higher probability of reading the communication insertion compared with others. Differences in relation to other demographic variables were not statistically significant. Newspapers are an excellent medium for communicating self appraisal kits for vision testing. The medium is cost effective and has significant reach in the urban agglomerates of India.
The use of a newspaper insertion to promote DIY testing of vision in India
Murthy, G; Gupta, S. K.; Dada, V. K.; Pant, T. D.; Savita, C.; Sanga, L.; Neena, J.
2001-01-01
BACKGROUND—The mass media have the potential to motivate people to participate in self appraisal of their own health status. An innovative communication package was designed to help people to examine vision at home. The impact of publishing the "do it yourself" (DIY) kit in Indian newspapers was evaluated. METHODS—A pretested bilingual vision testing kit was published in three newspapers. The kit comprised four tumbling Es corresponding to 6/12 line of Snellen's optotypes. Directions on using the kit were enclosed. 3 -7 days after publication of the kit, a telephone survey of newspaper readers was undertaken to evaluate the impact and cost effectiveness. RESULTS—603 people were contacted over the telephone. 125 (20.73%) subscribed to the newspaper carrying the DIY insertion. 43.2% (54) noticed the insertion of which 88.89% (48) read the enclosed instructions carefully. 58.33% respondents felt sufficiently motivated to contact an ophthalmologist. Graduates had a 3.83 times higher probability of reading the communication insertion compared with others. Differences in relation to other demographic variables were not statistically significant. CONCLUSIONS—Newspapers are an excellent medium for communicating self appraisal kits for vision testing. The medium is cost effective and has significant reach in the urban agglomerates of India. PMID:11466254
Comparison of microbial DNA enrichment tools for metagenomic whole genome sequencing.
Thoendel, Matthew; Jeraldo, Patricio R; Greenwood-Quaintance, Kerryl E; Yao, Janet Z; Chia, Nicholas; Hanssen, Arlen D; Abdel, Matthew P; Patel, Robin
2016-08-01
Metagenomic whole genome sequencing for detection of pathogens in clinical samples is an exciting new area for discovery and clinical testing. A major barrier to this approach is the overwhelming ratio of human to pathogen DNA in samples with low pathogen abundance, which is typical of most clinical specimens. Microbial DNA enrichment methods offer the potential to relieve this limitation by improving this ratio. Two commercially available enrichment kits, the NEBNext Microbiome DNA Enrichment Kit and the Molzym MolYsis Basic kit, were tested for their ability to enrich for microbial DNA from resected arthroplasty component sonicate fluids from prosthetic joint infections or uninfected sonicate fluids spiked with Staphylococcus aureus. Using spiked uninfected sonicate fluid there was a 6-fold enrichment of bacterial DNA with the NEBNext kit and 76-fold enrichment with the MolYsis kit. Metagenomic whole genome sequencing of sonicate fluid revealed 13- to 85-fold enrichment of bacterial DNA using the NEBNext enrichment kit. The MolYsis approach achieved 481- to 9580-fold enrichment, resulting in 7 to 59% of sequencing reads being from the pathogens known to be present in the samples. These results demonstrate the usefulness of these tools when testing clinical samples with low microbial burden using next generation sequencing. Copyright © 2016 Elsevier B.V. All rights reserved.
Mounajjed, Taofic; Brown, Char L; Stern, Therese K; Bjorheim, Annette M; Bridgeman, Andrew J; Rumilla, Kandelaria M; McWilliams, Robert R; Flotte, Thomas J
2014-11-01
The emergence of individualized medicine is driven by developments in precision diagnostics, epitomized by molecular testing. Because treatment decisions are being made based on such molecular data, data management is gaining major importance. Among data management challenges, creating workflow solutions for timely delivery of molecular data has become pivotal. This study aims to design and implement a scalable process that permits preappointment BRAF/KIT mutation analysis in melanoma patients, allowing molecular results necessary for treatment plans to be available before the patient's appointment. Process implementation aims to provide a model for efficient molecular data delivery for individualized medicine. We examined the existing process of BRAF/KIT testing in melanoma patients visiting our institution for oncology consultation. We created 5 working groups, each designing a specific segment of an alternative process that would allow preappointment BRAF/KIT testing and delivery of results. Data were captured and analyzed to evaluate the success of the alternative process. For 1 year, 35 (59%) of 55 patients had prior BRAF/KIT testing. The remaining 20 patients went through the new process of preappointment testing; results were available at the time of appointment for 12 patients (overall preappointment results availability, 85.5%). The overall process averaged 13.4 ± 4.7 days. In conclusion, we describe the successful implementation of a scalable workflow solution that permits preappointment BRAF/KIT mutation analysis and result delivery in melanoma patients. This sets the stage for further applications of this model to other conditions, answering an increasing demand for robust delivery of molecular data for individualized medicine. Copyright © 2014 Elsevier Inc. All rights reserved.
Tekin, Kemal; Albay, Ali; Simsek, Hulya; Sig, Ali Korhan; Guney, Mustafa
2017-01-01
Objective: The present study aimed to evaluate the performances of the BACTEC MGIT 960 SL DST kit and the GenoType MTBDRsl test for detecting second-line antituberculosis drug resistance in Multidrug-resistant TB (MDR-TB) cases. Materials and Methods: Forty-six MDR-TB strains were studied. Second-line antituberculosis drug resistances were detected using the BACTEC MGIT 960 SL DST kit and the GenoType MTBDRsl test. The Middlebrook 7H10 agar proportion method was used as the reference test. Results: The sensitivity and specificity values for the BACTEC MGIT 960 SL DST kit were both 100% for amikacin, kanamycin, capreomycin (4 µg/mL), and ofloxacin; 100% and 95.3%, respectively, for capreomycin (10 µg/mL); and 85.7% and 100%, respectively, for moxifloxacin (0.5 µg/mL). The sensitivity and specificity values for the GenoType MTBDRsl test to detect fluoroquinolone and aminoglycoside/cyclic peptide resistance were 88.9% and 100%, respectively, for ofloxacin and 85.7% and 94.9%, respectively, for moxifloxacin (0.5 µg/mL). The accuracy of the GenoType MTBDRsl assay for kanamycin, capreomycin, ofloxacin, and moxifloxacin was lower than that of the BACTEC MGIT 960 SL DST. Conclusion: The BACTEC MGIT 960 SL DST kit and the GenoType MTBDRsl were successful in detecting second-line antituberculosis drug resistance. Preliminary results of the GenoType MTBDRsl are very valuable for early treatment decisions, but we still recommend additional BACTEC MGIT 960 SL DST kit usage in the routine evaluation of drug-resistant tuberculosis. PMID:29123441
Tekin, Kemal; Albay, Ali; Simsek, Hulya; Sig, Ali Korhan; Guney, Mustafa
2017-10-01
The present study aimed to evaluate the performances of the BACTEC MGIT 960 SL DST kit and the GenoType MTBDRsl test for detecting second-line antituberculosis drug resistance in Multidrug-resistant TB (MDR-TB) cases. Forty-six MDR-TB strains were studied. Second-line antituberculosis drug resistances were detected using the BACTEC MGIT 960 SL DST kit and the GenoType MTBDRsl test. The Middlebrook 7H10 agar proportion method was used as the reference test. The sensitivity and specificity values for the BACTEC MGIT 960 SL DST kit were both 100% for amikacin, kanamycin, capreomycin (4 µg/mL), and ofloxacin; 100% and 95.3%, respectively, for capreomycin (10 µg/mL); and 85.7% and 100%, respectively, for moxifloxacin (0.5 µg/mL). The sensitivity and specificity values for the GenoType MTBDRsl test to detect fluoroquinolone and aminoglycoside/cyclic peptide resistance were 88.9% and 100%, respectively, for ofloxacin and 85.7% and 94.9%, respectively, for moxifloxacin (0.5 µg/mL). The accuracy of the GenoType MTBDRsl assay for kanamycin, capreomycin, ofloxacin, and moxifloxacin was lower than that of the BACTEC MGIT 960 SL DST. The BACTEC MGIT 960 SL DST kit and the GenoType MTBDRsl were successful in detecting second-line antituberculosis drug resistance. Preliminary results of the GenoType MTBDRsl are very valuable for early treatment decisions, but we still recommend additional BACTEC MGIT 960 SL DST kit usage in the routine evaluation of drug-resistant tuberculosis.
Vyas, S; Puwar, B; Patel, V; Bhatt, G; Kulkarni, S; Fancy, M
2014-05-01
Light microscopy of blood smears for diagnosis of malaria in the field has several limitations, notably delays in diagnosis. This study in Ahmedabad in Gujarat State, India, evaluated the diagnostic performance of a rapid diagnostic test for malaria (SD Bioline Malaria Ag P.f/Pan) versus blood smear examination as the gold standard. All fever cases presenting at 13 urban health centres were subjected to rapid diagnostic testing and thick and thin blood smears. A total of 677 cases with fever were examined; 135 (20.0%) tested positive by rapid diagnostic test and 86 (12.7%) by blood smear. The sensitivity of the rapid diagnostic test for malaria was 98.8%, specificity was 91.5%, positive predictive value 63.0% and negative predictive value 99.8%. For detection of Plasmodium falciparum the sensitivity of rapid diagnostic test was 100% and specificity was 97.3%. The results show the acceptability of the rapid test as an alternative to light microscopy in the field setting.
Commander Brand shaves in front of forward middeck lockers
NASA Technical Reports Server (NTRS)
1982-01-01
Commander Brand, wearing shorts, shaves in front of forward middeck lockers using personal hygiene mirror assembly (assy). Open modular locker single tray assy, Field Sequential (FS) crew cabin camera, communications kit assy mini headset (HDST) and HDST interface unit (HIU), personal hygiene kit, and meal tray assemblies appear in view.
Leuko, Stefan; Legat, Andrea; Fendrihan, Sergiu; Stan-Lotter, Helga
2004-01-01
Extremophilic archaea were stained with the LIVE/DEAD BacLight kit under conditions of high ionic strength and over a pH range of 2.0 to 9.3. The reliability of the kit was tested with haloarchaea following permeabilization of the cells. Microorganisms in hypersaline environmental samples were detectable with the kit, which suggests its potential application to future extraterrestrial halites. PMID:15528557
Maity, Susmita; Nandi, Srijita; Biswas, Subrata; Sadhukhan, Salil Kumar; Saha, Malay Kumar
2012-11-26
HIV, HBV and HCV pose a major public health problem throughout the world. Detection of infection markers for these agents is a major challenge for testing laboratories in a resource poor setting. As blood transfusion is an important activity saving millions of live every year, it also carries a risk of transfusion transmissible infections caused by these fatal blood borne pathogens if the quality of testing is compromised. Conventional ELISA is regarded as the mostly used screening technique but due to limitations like high cost, unavailability in many blood banks and testing sites, involvement of costly instruments, time taking nature and requirement of highly skilled personnel for interpretation, rapid tests are gaining more importance and warrants comparison of performance. A comparative study between these two techniques has been performed using commercially available diagnostic kits to assess their efficacy for detection of HIV, HBV and HCV infections. Rapid kits were more efficient in specificity with synthetic antigens along with high PPV than ELISA in most cases. Comparison between different ELISA kits revealed that Microlisa HIV and Hepalisa (J. Mitra & Co. Pvt. Ltd.); ERBA LISA HIV1 + 2, ERBA LISA Hepatitis B and ERBA LISA HCV (Transasia Bio-medicals Ltd.) gives uniform result with good performance in terms of sensitivity, specificity, PPV, NPV and efficiency, whereas, Microlisa HCV (J. Mitra & Co. Pvt. Ltd.), Microscreen HBsAg ELISA and INNOVA HCV (Span Diagnostics Ltd.) did not perform well. Rapid kits were also having high degree of sensitivity and specificity (100%) except in HIV Comb and HCV Comb (J. Mitra & Co. Pvt. Ltd.). The kit efficiency didn't vary significantly among different companies and lots in all the cases except for HCV ELISA showing statistically significant variation (p < 0.01) among three kit types. ELISA is a good screening assay for markers of HIV, HBV and HCV infections. Rapid tests are useful for further detection of false positive samples. ELISA seems the appropriate assay in blood bank. For availability of quality commercial diagnostic assays, evaluation of kit may be helpful.
2012-01-01
Background HIV, HBV and HCV pose a major public health problem throughout the world. Detection of infection markers for these agents is a major challenge for testing laboratories in a resource poor setting. As blood transfusion is an important activity saving millions of live every year, it also carries a risk of transfusion transmissible infections caused by these fatal blood borne pathogens if the quality of testing is compromised. Conventional ELISA is regarded as the mostly used screening technique but due to limitations like high cost, unavailability in many blood banks and testing sites, involvement of costly instruments, time taking nature and requirement of highly skilled personnel for interpretation, rapid tests are gaining more importance and warrants comparison of performance. Results A comparative study between these two techniques has been performed using commercially available diagnostic kits to assess their efficacy for detection of HIV, HBV and HCV infections. Rapid kits were more efficient in specificity with synthetic antigens along with high PPV than ELISA in most cases. Comparison between different ELISA kits revealed that Microlisa HIV and Hepalisa (J. Mitra & Co. Pvt. Ltd.); ERBA LISA HIV1 + 2, ERBA LISA Hepatitis B and ERBA LISA HCV (Transasia Bio-medicals Ltd.) gives uniform result with good performance in terms of sensitivity, specificity, PPV, NPV and efficiency, whereas, Microlisa HCV (J. Mitra & Co. Pvt. Ltd.), Microscreen HBsAg ELISA and INNOVA HCV (Span Diagnostics Ltd.) did not perform well. Rapid kits were also having high degree of sensitivity and specificity (100%) except in HIV Comb and HCV Comb (J. Mitra & Co. Pvt. Ltd.). The kit efficiency didn’t vary significantly among different companies and lots in all the cases except for HCV ELISA showing statistically significant variation (p < 0.01) among three kit types. Conclusions ELISA is a good screening assay for markers of HIV, HBV and HCV infections. Rapid tests are useful for further detection of false positive samples. ELISA seems the appropriate assay in blood bank. For availability of quality commercial diagnostic assays, evaluation of kit may be helpful. PMID:23181517
Pathologic Stimulus Determines Lineage Commitment of Cardiac C-kit+ Cells.
Chen, Zhongming; Zhu, Wuqiang; Bender, Ingrid; Gong, Wuming; Kwak, Il-Youp; Yellamilli, Amritha; Hodges, Thomas J; Nemoto, Natsumi; Zhang, Jianyi; Garry, Daniel J; van Berlo, Jop H
2017-12-12
Although cardiac c-kit + cells are being tested in clinical trials, the circumstances that determine lineage differentiation of c-kit + cells in vivo are unknown. Recent findings suggest that endogenous cardiac c-kit + cells rarely contribute cardiomyocytes to the adult heart. We assessed whether various pathological stimuli differentially affect the eventual cell fates of c-kit + cells. We used single-cell sequencing and genetic lineage tracing of c-kit + cells to determine whether various pathological stimuli would result in different fates of c-kit + cells. Single-cell sequencing of cardiac CD45 - c-kit + cells showed innate heterogeneity, indicative of the existence of vascular and mesenchymal c-kit + cells in normal hearts. Cardiac pressure overload resulted in a modest increase in c-kit-derived cardiomyocytes, with significant increases in the numbers of endothelial cells and fibroblasts. Doxorubicin-induced acute cardiotoxicity did not increase c-kit-derived endothelial cell fates but instead induced cardiomyocyte differentiation. Mechanistically, doxorubicin-induced DNA damage in c-kit + cells resulted in expression of p53. Inhibition of p53 blocked cardiomyocyte differentiation in response to doxorubicin, whereas stabilization of p53 was sufficient to increase c-kit-derived cardiomyocyte differentiation. These results demonstrate that different pathological stimuli induce different cell fates of c-kit + cells in vivo. Although the overall rate of cardiomyocyte formation from c-kit + cells is still below clinically relevant levels, we show that p53 is central to the ability of c-kit + cells to adopt cardiomyocyte fates, which could lead to the development of strategies to preferentially generate cardiomyocytes from c-kit + cells. © 2017 American Heart Association, Inc.
Factor Analysis of the WAIS and Twenty French-Kit Reference Tests.
ERIC Educational Resources Information Center
Ramsey, Philip H.
1979-01-01
The Wechsler Adult Intelligence Scale (WAIS) and 20 tests from the French Kit were administered to over 100 undergraduates. Analyses revealed ten factors: verbal comprehension, visualization, memory span, syllogistic reasoning, general reasoning, induction, mechanical knowledge, number facility, spatial orientation, and associative memory.…
Costa Casagrande, T A; de Oliveira Barros, L M; Fukumasu, H; Cogliati, B; Chaible, L M; Dagli, M L Z; Matera, J M
2015-03-01
This study investigated the correlation between KIT gene expression determined by immunohistochemistry and real-time polymerase chain reaction (RT-PCR) and the rate of tumour recurrence and tumour-related deaths in dogs affected with mast cell tumour (MCT). Kaplan-Meier curves were constructed to compare tumour recurrence and tumour-related death between patients. The log-rank test was used to check for significant differences between curves. KIT-I, KIT-II and KIT-III staining patterns were observed in 9 (11.11%), 50 (61.73%) and 22 (27.16%) tumours, respectively. Tumour recurrence rates and tumour-related deaths were not associated with KIT staining patterns (P = 0278, P > 0.05), KIT (P = 0.289, P > 0.05) or KIT ligand (P = 0.106, P > 0.05) gene expression. Despite the lack of association between KIT staining pattern and patient survival time, the results suggest a correlation between aberrant KIT localization and increased proliferative activity of MCTs. RT-PCR seems to be a sensible method for quantitative detection of KIT gene expression in canine MCT, although expressions levels are not correlated with prognosis. © 2013 Blackwell Publishing Ltd.
Antonescu, Cristina R; Sommer, Gunhild; Sarran, Lisa; Tschernyavsky, Sylvia J; Riedel, Elyn; Woodruff, James M; Robson, Mark; Maki, Robert; Brennan, Murray F; Ladanyi, Marc; DeMatteo, Ronald P; Besmer, Peter
2003-08-15
Activating mutations of the KIT juxtamembrane region are the most common genetic events in gastrointestinal stromal tumors (GISTs) and have been noted as independent prognostic factors. The impact of KIT mutation in other regions, such as the extracellular or kinase domains, is not well-defined and fewer than 30 cases have been published to date. One hundred twenty GISTs, confirmed by KIT immunoreactivity, were evaluated for the presence of KIT exon 9, 11, 13, and 17 mutations. The relation between the presence/type of KIT mutation and clinicopathological factors was analyzed using Fisher's exact test and log-rank test. Forty-four % of the tumors were located in the stomach, 47% in the small bowel, 6% in the rectum, and 3% in the retroperitoneum. Overall, KIT mutations were detected in 78% of patients as follows: 67% in exon 11, 11% in exon 9, and none in exon 13 or 17. The types of KIT exon 11 mutations were heterogeneous and clustered in the classic "hot spot" at the 5' end of exon 11. Seven % of cases showed internal tandem duplications (ITD) at the 3' end of exon 11, in a region that we designate as a second hot spot for KIT mutations. Interestingly, these cases were associated with: female predominance, stomach location, occurrence in older patients, and favorable outcome. There were significant associations between exon 9 mutations and large tumor size (P < 0.001) and extragastric location (P = 0.02). Ten of these 13 patients with more than 1-year follow-up have developed recurrent disease. Most KIT-expressing GISTs show KIT mutations that are preferentially located within the classic hot spot of exon 11. In addition, we found an association between a second hot spot at the 3'end of exon 11, characterized by ITDs, and a subgroup of clinically indolent gastric GISTs in older females. KIT exon 9 mutations seem to define a distinct subset of GISTs, located predominantly in the small bowel and associated with an unfavorable clinical course.
Technology Assessment and Strategy for Development of a Rapid Field Water Microbiology Test Kit
1991-09-01
fresh and marine waters (Santiago- Mercado and Hazen 1987; Valdes-Collazo et al. 1987; Perez-Rosas and Hazen 1988; Bermudez and Hazen 1988; Rivera et al...Santiago- Mercado and Hazen 1987; Valdes-Collazo et al. 1987). Investigators are constantly improving the coltform-MF technique as it is the... Mercado and Hazen 1987; Valdes-Collazo et al. 1987; Perez-Rosas and Hazen 1988; Bermudez and Hazen 1988; Rivera et al. 1988). The tropical conditions
[Consistency study of PowerPlex 21 kit and Goldeneye 20A kit and forensic application].
Ren, He; Liu, Ying; Zhang, Qing-Xia; Jiao, Zhang-Ping
2014-06-01
To ensure the consistency of genotype results for PowerPlex 21 kit and Goldeneye 20A kit. The STR loci were amplified in DNA samples from 205 unrelated individuals in Beijing Han population. And consistency of 19 overlap STR loci typing were observed. The genetic polymorphism of D1S1656 locus was obtained. All 19 overlap loci typing showed consistent. The proportion of peak height of heterozygous loci in two kits showed no statistical difference (P > 0.05). The observed heterozygosis of D1S1656 was 0.878. The discrimination power was 0.949. The excluding probability of paternity of triplet was 0.751. The excluding probability of paternity of diploid was 0.506. The polymorphism information content was 0.810. PowerPlex 21 kit and Goldeneye 20A kit present a good consistency. The primer design is reasonable. The polymorphism of D1S1656 is good. The two kits can be used for human genetic analysis, paternity test, and individual identification in forensic practice.
Gutierrez, Dario A; Muralidhar, Sathya; Feyerabend, Thorsten B; Herzig, Stephan; Rodewald, Hans-Reimer
2015-05-05
Obesity, insulin resistance, and related pathologies are associated with immune-mediated chronic inflammation. Kit mutant mice are protected from diet-induced obesity and associated co-morbidities, and this phenotype has previously been attributed to their lack of mast cells. We performed a comprehensive metabolic analysis of Kit-dependent Kit(W/Wv) and Kit-independent Cpa3(Cre/+) mast-cell-deficient mouse strains, employing diet-induced or genetic (Lep(Ob/Ob) background) models of obesity. Our results show that mast cell deficiency, in the absence of Kit mutations, plays no role in the regulation of weight gain or insulin resistance. Moreover, we provide evidence that the metabolic phenotype observed in Kit mutant mice, while independent of mast cells, is immune regulated. Our data underscore the value of definitive mast cell deficiency models to conclusively test the involvement of this enigmatic cell in immune-mediated pathologies and identify Kit as a key hematopoietic factor in the pathogenesis of metabolic syndrome. Copyright © 2015 Elsevier Inc. All rights reserved.
In-field tests of the EURITRACK tagged neutron inspection system
NASA Astrophysics Data System (ADS)
Carasco, C.; Perot, B.; Bernard, S.; Mariani, A.; Szabo, J.-L.; Sannie, G.; Roll, Th.; Valkovic, V.; Sudac, D.; Viesti, G.; Lunardon, M.; Bottosso, C.; Fabris, D.; Nebbia, G.; Pesente, S.; Moretto, S.; Zenoni, A.; Donzella, A.; Moszynski, M.; Gierlik, M.; Batsch, T.; Wolski, D.; Klamra, W.; Le Tourneur, P.; Lhuissier, M.; Colonna, A.; Tintori, C.; Peerani, P.; Sequeira, V.; Salvato, M.
2008-04-01
The EURopean Illicit TRAfficking Countermeasures Kit (EURITRACK) inspection system has been designed to complement X-ray scanners in the detection of explosives and other illicit materials hidden in cargo containers. The containers are interrogated by a 14-MeV tagged neutron beam at any suspect position in the X-ray image. Interrogation of a specific volume element with tagged neutrons yields information about the chemical composition of the material. Implementation and performance tests of the EURITRACK system in the Port of Rijeka in Croatia are described. Cargo container inspection results are reported and discussed.
Personal Computer-less (PC-less) Microcontroller Training Kit
NASA Astrophysics Data System (ADS)
Somantri, Y.; Wahyudin, D.; Fushilat, I.
2018-02-01
The need of microcontroller training kit is necessary for practical work of students of electrical engineering education. However, to use available training kit not only costly but also does not meet the need of laboratory requirements. An affordable and portable microcontroller kit could answer such problem. This paper explains the design and development of Personal Computer Less (PC-Less) Microcontroller Training Kit. It was developed based on Lattepanda processor and Arduino microcontroller as target. The training kit equipped with advanced input-output interfaces that adopted the concept of low cost and low power system. The preliminary usability testing proved this device can be used as a tool for microcontroller programming and industrial automation training. By adopting the concept of portability, the device could be operated in the rural area which electricity and computer infrastructure are limited. Furthermore, the training kit is suitable for student of electrical engineering student from university and vocational high school.
High explosive spot test analyses of samples from Operable Unit (OU) 1111
DOE Office of Scientific and Technical Information (OSTI.GOV)
McRae, D.; Haywood, W.; Powell, J.
1995-01-01
A preliminary evaluation has been completed of environmental contaminants at selected sites within the Group DX-10 (formally Group M-7) area. Soil samples taken from specific locations at this detonator facility were analyzed for harmful metals and screened for explosives. A sanitary outflow, a burn pit, a pentaerythritol tetranitrate (PETN) production outflow field, an active firing chamber, an inactive firing chamber, and a leach field were sampled. Energy dispersive x-ray fluorescence (EDXRF) was used to obtain semi-quantitative concentrations of metals in the soil. Two field spot-test kits for explosives were used to assess the presence of energetic materials in the soilmore » and in items found at the areas tested. PETN is the major explosive in detonators manufactured and destroyed at Los Alamos. No measurable amounts of PETN or other explosives were detected in the soil, but items taken from the burn area and a high-energy explosive (HE)/chemical sump were contaminated. The concentrations of lead, mercury, and uranium are given.« less
Biranjia-Hurdoyal, Susheela D; Seetulsingh-Goorah, Sharmila P
2016-01-01
The aim was to determine the performances of four Helicobacter pylori serological detection kits in different target groups, using Amplified IDEIA™ Hp StAR™ as gold standard. Kits studied were Rapid Immunochromatoghraphic Hexagon, Helicoblot 2.1, an EIA IgG kit and EIA IgA kit. Stool and blood samples were collected from 162 apparently healthy participants (control) and 60 Type 2 diabetes mellitus (T2DM) patients. The performances of the four serological detection kits were found to be affected by gender, age, health status and ethnicity of the participants. In the control group, the Helicoblot 2.1 kit had the best performance (AUC = 0.85; p<0.05, accuracy = 86.4%), followed by EIA IgG (AUC = 0.75; p<0.05, accuracy = 75.2%). The Rapid Hexagon and EIA IgA kits had relatively poor performances. In the T2DM subgroup, the kits H2.1 and EIA IgG had best performances, with accuracies of 96.5% and 93.1% respectively. The performance of EIA IgG improved with adjustment of its cut-off value. The performances of the detection kits were affected by various factors which should be taken into consideration.
Crosby, Richard A; Stradtman, Lindsay; Collins, Tom; Vanderpool, Robin
2017-09-01
To determine the return rate of community-delivered fecal immunochemical test (FIT) kits in a rural population and to identify significant predictors of returning kits. Residents were recruited in 8 rural Kentucky counties to enroll in the study and receive an FIT kit. Of 345 recruited, 82.0% returned an FIT kit from the point of distribution. These participants were compared to the remainder relative to age, sex, marital status, having an annual income below $15,000, not graduating from high school, not having a regular health care provider, not having health care coverage, being a current smoker, indicating current overweight or obese status, and a scale measure of fatalism pertaining to colorectal cancer. Predictors achieving significance at the bivariate level were entered into a stepwise logistic regression model to calculate adjusted OR and 95% CI. The return rate was 82.0%. In adjusted analyses, those indicating an annual income of less than $15,000 were 2.85 times more likely to return their kits (95% CI: 1.56-5.24; P < .001). Also, those not perceiving themselves to be overweight/obese were 1.95 times more likely to return their kits (95% CI: 1.07-3.55; P = .029). An outreach-based colorectal cancer screening program in a rural population may yield high return rates. People with annual incomes below $15,000 and those not having perceptions of being overweight/obese may be particularly likely to return FIT kits. © 2016 National Rural Health Association.
Design, Certification, and Deployment of the Colorimetric Water Quality Monitoring Kit (CWQMK)
NASA Technical Reports Server (NTRS)
Gazda, Daniel B.; Nolan, Daniel J.; Rutz, Jeff A.; Schultz, John R.; Siperko, Lorraine M.; Porter, Marc D.; Lipert, Robert J.; Flint, Stephanie M.; McCoy, J. Torin
2010-01-01
In August 2009, an experimental water quality monitoring kit based on Colorimetric Solid Phase Extraction (CSPE) technology was delivered to the International Space Station (ISS) aboard STS-128/17A. The kit, called the Colorimetric Water Quality Monitoring Kit (CWQMK), was flown and deployed as a Station Development Test Objective (SDTO) experiment on the ISS. The goal of the SDTO experiment is to evaluate the acceptability of CSPE technology for routine water quality monitoring on the ISS. This paper provides an overview of the SDTO experiment, as well as a detailed description of the CWQMK hardware and a summary of the testing and analysis conducted to certify the CWQMK for use on the ISS. The initial results obtained from the SDTO experiment are also reported and discussed in detail
Zhong, F; Tang, W; Cheng, W; Lin, P; Wu, Q; Cai, Y; Tang, S; Fan, L; Zhao, Y; Chen, X; Mao, J; Meng, G; Tucker, J D; Xu, H
2017-05-01
HIV self-testing (HIVST) offers an opportunity to increase HIV testing among people not reached by facility-based services. However, the promotion of HIVST is limited as a consequence of insufficient community engagement. We built a social entrepreneurship testing (SET) model to promote HIVST linkage to care among Chinese men who have sex with men (MSM) in Guangzhou. The SET model includes a few key steps. Each participant first completed an online survey, and paid a US$23 (refundable) deposit to receive an HIVST kit and a syphilis self-testing (SST) kit. After the testing, the results were sent to the platform by the participants and interpreted by Center for Disease Control and Prevention (CDC) staff. Meanwhile, the deposit was returned to each participant. Finally, the Community based organizations (CBO) contacted the participants to provide counselling services, confirmation testing and linkage to care. During April-June 2015, a total of 198 MSM completed a preliminary survey and purchased self-testing kits. The majority were aged < 34 years (84.4%) and met partners online (93.1%). In addition, 68.9% of participants had ever been tested for HIV, and 19.5% had ever performed HIVST. Overall, feedback was received from 192 participants (97.0%). Of these participants, 14 people did not use the kits; among those who did use the kits, the HIV and syphilis prevalences were 4.5% (eight of 178) and 3.7% (six of 178), respectively. All of the screened HIV-positive individuals sought further confirmation testing and were linked to care. Using an online SET model to promote HIV and syphilis self-testing among Chinese MSM is acceptable and feasible, and this model adds a new testing platform to the current testing service system. © 2016 British HIV Association.
Birth kits for safe motherhood in Bangladesh.
Nessa, S; Arco, E S; Kabir, I A
1992-01-01
Tetanus infection remains the leading cause of high neonatal mortality in Bangladesh. Birth kits which instruct and assist in a clean, safe birth are seen as a key measure in reducing the high incidence of neonatal deaths. A multisectoral programme has developed a simple kit and tested its potential for distribution to pregnant women. Initial results are positive and development is continuing.
Campbell, Rebecca; Feeney, Hannah; Fehler-Cabral, Giannina; Shaw, Jessica; Horsford, Sheena
2015-12-23
Victims of sexual assault are often advised to have a medical forensic exam and sexual assault kit (SAK; also termed a "rape kit") to preserve physical evidence (e.g., semen, blood, and/or saliva samples) to aid in the investigation and prosecution of the crime. Law enforcement are tasked with submitting the rape kit to a forensic laboratory for DNA (deoxyribonucleic acid) analysis, which can be instrumental in identifying offenders in previously unsolved crimes, confirming identify in known-offender assaults, discovering serial rapists, and exonerating individuals wrongly accused. However, a growing number of media stories, investigative advocacy projects, and social science studies indicate that police are not routinely submitting SAKs for forensic testing, and instead rape kits are placed in evidence storage, sometimes for decades. This review article examines the growing national problem of untested rape kits by summarizing current research on the number of untested SAKs in the United States and exploring the underlying reasons why police do not submit this evidence for DNA testing. Recommendations for future research that can guide policy and practice are discussed. © The Author(s) 2015.
Su, Feng; Zhang, Wentian; Liu, Jianfang
2015-01-01
It has been validated that c-kit positive (c-kit+) cells in infarcted myocardium are from bone marrow (BM). Given the recent study that in the heart, estrogen receptor alpha (ERα) is involved in adaptive mechanisms by supporting cardiomyocytes survival via post-infarct cardiac c-kit+ cells, we tested a novel hypothesis that membrane ERα (mERа) supports survival of BM c-kit+ cells and enhance protective paracrine function for cardiac repair. Our data showed that myocardial infarction (MI) leads to an increase in c-kit+ first in bone marrow and then specifically within the infarcted myocardium. Also up-regulated mERа in post-infarct BM c-kit+ cells was found in day 3 post MI. In vitro co-culture system, mERа+ enhances the beneficial effects of BM c-kit+ cells by increasing their viability and reducing apoptosis. Post-infarct c-kit+ mERа+ cells population expresses predominant ERα and holds self-renewal as well as cardiac differentiation potentials after MI. In vivo, BM c-kit+ cells reduced infarct size, fibrosis and improved cardiac function. In conclusion, BM c-kit+ mERа+ exerted significantly cardiac protection after MI. A potential important implication of this study is that the manipulation of BM c-kit+ stem cells with ERа-dependent fashion may be helpful in recovering functional performance after cardiac tissue injury. PMID:26191121
Chen, Qixia; An, Jingna; Rao, Chenli; Wang, Tingting; Li, Dongdong; Feng, Shu; Tao, Chuanmin
2016-01-01
Syphilis is a major concern to global public health with increasing incidence. So its screening test should have sufficient sensitivity and specificity. We evaluated the performance of the Lumipulse G TP-N assay detection for syphilis screening and compared it with the InTec ELISA test kit for TP, which is widely used. Samples of several patient groups including 133 clinical and serologically characterized syphilitic sera, 175 samples containing potentially interfering agents, and 2290 unselected samples submitted for routine screening were detected by both the Lumipulse G TP-N assay and the InTec ELISA test kit for TP. Inconsistent samples were confirmed by RecomLine Treponema IgG, IgM immunoblot. Coefficient of variations of the Lumipulseo G TP-N assay at both levels were below 5% and of the InTec ELISA test kit for TP both over 5%. The sensitivity of the Lumipulse G TP-N assay and the InTec ELISA test kit for TP were 100% for all stages of syphilis. The two methods had consistent analytical specificity of 100% (95% CI: 97.21 - 100.00), while the clinical specificity was 100% (95% CI: 99.79 - 100.00) and 99.82% (95% CI: 99.51 - 99.94), respectively. Between them, Spearman's correlation coefficient was 0.455 and kappa value was 0.986. The overall sensitivity and specificity of the Lumipulse G TP-N assay was higher than the InTec ELISA test kit for TP (sensitivity: 100.0 versus 99.5, specificity: 100.0 versus 99.8). The automated Lumipulse G TP-N assay demonstrated excellent diagnostic sensitivity and specificity when evaluated as a screening test for syphilis. Thus, it can be an alternative to the treponemal screening test.
Code of Federal Regulations, 2011 CFR
2011-01-01
... of Ceiling Fan Light Kits V Appendix V to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. V Appendix V to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of Ceiling Fan...
1997-04-18
Marshall's Neutral Buoyancy Simulator (NBS) is used to simulate the gravitational fields and buoyancy effects outer space has on astronauts and their ability to perform tasks in this environment. In this example, a diver performs a temporary fluid line repair task using a repair kit developed by Marshall engineers. The analysis will determine the value of this repair kit and its feasibility.
Community Renewal. Experiences from the Field. An Adult Educator's Resource Kit. 2nd Edition.
ERIC Educational Resources Information Center
Le Baron, Beth; And Others
This kit suggests ideas and resources for adult educators and other community workers to use in assisting individuals, groups, and communities to respond effectively to a changing economy. Introductory materials provide the purpose, a note on content arrangement, and suggestions for program methods and program planning. The main portion of the kit…
Attitudes towards HIV testing via home-sampling kits ordered online (RUClear pilots 2011-12).
Ahmed-Little, Y; Bothra, V; Cordwell, D; Freeman Powell, D; Ellis, D; Klapper, P; Scanlon, S; Higgins, S; Vivancos, R
2016-09-01
The burden of disease relating to undiagnosed HIV infection is significant in the UK. BHIVA (British HIV Association) recommends population screening in high prevalence areas, expanding outside traditional antenatal/GUM settings. RUClear 2011-12 piloted expanding HIV testing outside traditional settings using home-sampling kits (dry-blood-spot testing) ordered online. Greater Manchester residents (≥age 16) could request testing via an established, online chlamydia testing service (www.ruclear.co.uk). Participant attitudes towards this new service were assessed. Qualitative methods (thematic analysis) were used to analyse free-text data submitted by participants via hard copy questionnaires issued in all testing kits. 79.9% (2447/3062) participants completed questionnaires, of which 30.9% (756/2447) provided free-text data. Participants overwhelmingly supported the service, valuing particularly accessibility and convenience, allowing individuals to order tests any time of day and self-sample comfortably at home; avoiding the invasive nature of venipuncture and avoiding the need for face-to-face interaction with health services. The pilot was also clinically and cost-effective. Testing via home-sampling kits ordered online (dry-blood-spot testing) was felt to be an acceptable and convenient method for accessing a HIV test. Many individuals undertook HIV testing where they would otherwise not have been tested at all. Expansion of similar services may increase the uptake of HIV testing. © The Author 2015. Published by Oxford University Press on behalf of Faculty of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Reyes-Sebastian, Josefina; Montiel-Cervantes, Laura Arcelia; Reyes-Maldonado, Elba; Dominguez-Lopez, Maria Lilia; Ortiz-Butron, Rocio; Castillo-Alvarez, Aida; Lezama, Ruth Angélica
2018-03-01
Receptor tyrosine kinase (RTK) activity may contribute to carcinogenesis. The c-Kit receptor, a member of the RTK family, is expressed in immature haematopoietic system cells. Acute lymphoblastic leukaemia (ALL) presents incompletely differentiated lymphoblasts, and consequently, c-Kit expression can be detected in these cells. The BCR-ABL kinase, which is usually present in both ALL and chronic myeloid leukaemia, can trigger signalling pathways with neoplastic effects. However, a certain number of ALL patients and chronic myeloid leukaemia patients do not express this kinase, raising the question of which other proteins that intervene in signalling pathways may be involved in the development of these diseases. To test whether c-Kit has proliferative effects and affects the inhibition of apoptosis of leukaemic lymphoblasts that do not express BCR-ABL. We cultured RS4:11 lymphoblasts and analysed the expression and activation of c-Kit by immunofluorescence, and flow cytometry, evaluation of cell proliferation, apoptosis, cyclin D1 and Bak expression were carried out by flow cytometry; activation of AKT and survivin expression were tested by immunoblot. The c-Kit receptor was found to induce proliferation and to increase the expression of cyclin D1 via the PI3K/AKT/NF-kB signalling pathway. Additionally, the c-Kit/PI3K/AKT pathway increased the inhibition of apoptosis and survivin expression. Similarly, c-Kit was observed to reduce the expression of the pro-apoptotic Bak protein. These results suggest that, in leukaemic lymphoblasts, c-Kit triggers a signalling pathway with proliferative and anti-apoptotic effects; information to this effect has not yet been reported in the literature.
Quantitative detection of PfHRP2 in saliva of malaria patients in the Philippines
2012-01-01
Background Malaria is a global health priority with a heavy burden of fatality and morbidity. Improvements in field diagnostics are needed to support the agenda for malaria elimination. Saliva has shown significant potential for use in non-invasive diagnostics, but the development of off-the-shelf saliva diagnostic kits requires best practices for sample preparation and quantitative insight on the availability of biomarkers and the dynamics of immunoassay in saliva. This pilot study measured the levels of the PfHRP2 in patient saliva to inform the development of salivary diagnostic tests for malaria. Methods Matched samples of blood and saliva were collected between January and May, 2011 from eight patients at Palawan Baptist Hospital in Roxas, Palawan, Philippines. Parasite density was determined from thick-film blood smears. Concentrations of PfHRP2 in saliva of malaria-positive patients were measured using a custom chemiluminescent ELISA in microtitre plates. Sixteen negative-control patients were enrolled at UCLA. A substantive difference between this protocol and previous related studies was that saliva samples were stabilized with protease inhibitors. Results Of the eight patients with microscopically confirmed P. falciparum malaria, seven tested positive for PfHRP2 in the blood using rapid diagnostic test kits, and all tested positive for PfHRP2 in saliva. All negative-control samples tested negative for salivary PfHRP2. On a binary-decision basis, the ELISA agreed with microscopy with 100 % sensitivity and 100 % specificity. Salivary levels of PfHRP2 ranged from 17 to 1,167 pg/mL in the malaria-positive group. Conclusion Saliva is a promising diagnostic fluid for malaria when protein degradation and matrix effects are mitigated. Systematic quantitation of other malaria biomarkers in saliva would identify those with the best clinical relevance and suitability for off-the-shelf diagnostic kits. PMID:22631858
Lakshminarayana, Rashmi; Eble, Alex; Bhakta, Preetha; Frost, Chris; Boone, Peter; Elbourne, Diana; Mann, Vera
2013-01-01
The aim of the STRIPES trial was to assess the effectiveness of providing supplementary, remedial teaching and learning materials (and an additional 'kit' of materials for girls) on a composite of language and mathematics test scores for children in classes two, three and four in public primary schools in villages in the Nagarkurnool division of Andhra Pradesh, India. STRIPES was a cluster randomised trial in which 214 villages were allocated either to the supplementary teaching intervention (n = 107) or to serve as controls (n = 107). 54 of the intervention villages were further randomly allocated to receive additional kit for girls. The study was not blinded. Analysis was conducted on the intention to treat principle, allowing for clustering. Composite test scores were significantly higher in the intervention group (107 villages; 2364 children) than in the control group (106 villages; 2014 children) at the end of the trial (mean difference on a percentage scale 15.8; 95% CI 13.1 to 18.6; p<0.001; 0.75 Standard Deviation (SD) difference). Composite test scores were not significantly different in the 54 villages (614 girls) with the additional kits for girls compared to the 53 villages (636 girls) without these kits at the end of the trial (mean difference on a percentage scale 0.5; 95% CI -4.34 to 5.4; p = 0.84). The cost per 0.1 SD increase in composite test score for intervention without kits is Rs. 382.97 (£4.45, $7.13), and Rs.480.59 (£5.58, $8.94) for the intervention with kits. A 18 month programme of supplementary remedial teaching and learning materials had a substantial impact on language and mathematics scores of primary school students in rural Andhra Pradesh, yet providing a 'kit' of materials to girls in these villages did not lead to any measured additional benefit. Controlled-Trials.com ISRCTN69951502.
Bogdanovska-Todorovska, Magdalena; Petrushevska, Gordana; Janevska, Vesna; Spasevska, Liljana; Kostadinova-Kunovska, Slavica
2018-05-20
Accurate assessment of human epidermal growth factor receptor 2 (HER-2) is crucial in selecting patients for targeted therapy. Commonly used methods for HER-2 testing are immunohistochemistry (IHC) and fluorescence in situ hybridization (FISH). Here we presented the implementation, optimization and standardization of two FISH protocols using breast cancer samples and assessed the impact of pre-analytical and analytical factors on HER-2 testing. Formalin fixed paraffin embedded (FFPE) tissue samples from 70 breast cancer patients were tested for HER-2 using PathVysion™ HER-2 DNA Probe Kit and two different paraffin pretreatment kits, Vysis/Abbott Paraffin Pretreatment Reagent Kit (40 samples) and DAKO Histology FISH Accessory Kit (30 samples). The concordance between FISH and IHC results was determined. Pre-analytical and analytical factors (i.e., fixation, baking, digestion, and post-hybridization washing) affected the efficiency and quality of hybridization. The overall hybridization success in our study was 98.6% (69/70); the failure rate was 1.4%. The DAKO pretreatment kit was more time-efficient and resulted in more uniform signals that were easier to interpret, compared to the Vysis/Abbott kit. The overall concordance between IHC and FISH was 84.06%, kappa coefficient 0.5976 (p < 0.0001). The greatest discordance (82%) between IHC and FISH was observed in IHC 2+ group. A standardized FISH protocol for HER-2 assessment, with high hybridization efficiency, is necessary due to variability in tissue processing and individual tissue characteristics. Differences in the pre-analytical and analytical steps can affect the hybridization quality and efficiency. The use of DAKO pretreatment kit is time-saving and cost-effective.
Mitarai, Satoshi; Kato, Seiya; Ogata, Hideo; Aono, Akio; Chikamatsu, Kinuyo; Mizuno, Kazue; Toyota, Emiko; Sejimo, Akiko; Suzuki, Katsuhiro; Yoshida, Shiomi; Saito, Takefumi; Moriya, Ataru; Fujita, Akira; Sato, Shuko; Matsumoto, Tomoshige; Ano, Hiromi; Suetake, Toshinori; Kondo, Yuji; Mori, Toru
2012-01-01
We evaluated a new line probe assay (LiPA) kit to identify Mycobacterium species and to detect mutations related to drug resistance in Mycobacterium tuberculosis. A total of 554 clinical isolates of Mycobacterium tuberculosis (n = 316), Mycobacterium avium (n = 71), Mycobacterium intracellulare (n = 51), Mycobacterium kansasii (n = 54), and other Mycobacterium species (n = 62) were tested with the LiPA kit in six hospitals. The LiPA kit was also used to directly test 163 sputum specimens. The results of LiPA identification of Mycobacterium species in clinical isolates were almost identical to those of conventional methods. Compared with standard drug susceptibility testing results for the clinical isolates, LiPA showed a sensitivity and specificity of 98.9% and 97.3%, respectively, for detecting rifampin (RIF)-resistant clinical isolates; 90.6% and 100%, respectively, for isoniazid (INH) resistance; 89.7% and 96.0%, respectively, for pyrazinamide (PZA) resistance; and 93.0% and 100%, respectively, for levofloxacin (LVX) resistance. The LiPA kit could detect target species directly in sputum specimens, with a sensitivity of 85.6%. Its sensitivity and specificity for detecting RIF-, PZA-, and LVX-resistant isolates in the sputum specimens were both 100%, and those for detecting INH-resistant isolates were 75.0% and 92.9%, respectively. The kit was able to identify mycobacterial bacilli at the species level, as well as drug-resistant phenotypes, with a high sensitivity and specificity. PMID:22205814
Paternity tests in Mexico: Results obtained in 3005 cases.
García-Aceves, M E; Romero Rentería, O; Díaz-Navarro, X X; Rangel-Villalobos, H
2018-04-01
National and international reports regarding the paternity testing activity scarcely include information from Mexico and other Latin American countries. Therefore, we report different results from the analysis of 3005 paternity cases analyzed during a period of five years in a Mexican paternity testing laboratory. Motherless tests were the most frequent (77.27%), followed by trio cases (20.70%); the remaining 2.04% included different cases of kinship reconstruction. The paternity exclusion rate was 29.58%, higher but into the range reported by the American Association of Blood Banks (average 24.12%). We detected 65 mutations, most of them involving one-step (93.8% and the remaining were two-step mutations (6.2%) thus, we were able to estimate the paternal mutation rate for 17 different STR loci: 0.0018 (95% CI 0.0005-0.0047). Five triallelic patterns and 12 suspected null alleles were detected during this period; however, re-amplification of these samples with a different Human Identification (HID) kit confirmed the homozygous genotypes, which suggests that most of these exclusions actually are one-step mutations. HID kits with ≥20 STRs detected more exclusions, diminishing the rate of inconclusive results with isolated exclusions (<3 loci), and leading to higher paternity indexes (PI). However, the Powerplex 21 kit (20 STRs) and Powerplex Fusion kit (22 STRs) offered similar PI (p = 0.379) and average number of exclusions (PE) (p = 0.339) when a daughter was involved in motherless tests. In brief, besides to report forensic parameters from paternity tests in Mexico, results describe improvements to solve motherless paternity tests using HID kits with ≥20 STRs instead of one including 15 STRs. Copyright © 2018 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.
Crist, A E; Dietz, T J; Kampschroer, K
1996-01-01
The MUREX C. albicans (MC)(Murex Diagnostics), Albicans-Sure (AS) (Clinical Standards Laboratories), and BactiCard Candida (BC) (Remel) test kits were compared with the germ tube (GT) test for the rapid, presumptive identification of Candida albicans. All three test kits detect the enzymes L-proline aminopeptidase and beta-galactosaminidase in yeast cells grown on culture media and are based on the principle that C. albicans produces both enzymes whereas other yeasts produce only one or neither of the enzymes. The organisms evaluated were fresh clinical isolates identified by methods routinely used in our laboratory (API 20C system and conventional methods) and included 303 C. albicans isolates, 153 Candida glabrata isolates, 70 Candida tropicalis isolates, 36 Candida parapsilosis isolates, 13 isolates of other Candida spp., 5 Cryptococcus neoformans isolates, and 3 Saccharomyces cerevisiae isolates. The MC, AS, BC, and GT tests detected 299 (98.7%), 300 (99.0%), 301 (99.3%), and 287 (94.7%) C. albicans isolates, respectively. There was one false-positive result with both the MC and BC kits and two false-positive results with the GT test. The enzymatic methods evaluated in this study provide rapid and accurate alternatives to the GT test for the presumptive identification of C. albicans. PMID:8880535
Mukhtar, Maowia; Ali, Sababil S.; Boshara, Salah A.; Albertini, Audrey; Monnerat, Séverine; Bessell, Paul; Mori, Yasuyoshi; Kubota, Yutaka; Ndung’u, Joseph M.
2018-01-01
Background Confirmatory diagnosis of visceral leishmaniasis (VL), as well as diagnosis of relapses and test of cure, usually requires examination by microscopy of samples collected by invasive means, such as splenic, bone marrow or lymph node aspirates. This causes discomfort to patients, with risks of bleeding and iatrogenic infections, and requires technical expertise. Molecular tests have great potential for diagnosis of VL using peripheral blood, but require well-equipped facilities and trained personnel. More user-friendly, and field-amenable options are therefore needed. One method that could meet these requirements is loop-mediated isothermal amplification (LAMP) using the Loopamp Leishmania Detection Kit, which comes as dried down reagents that can be stored at room temperature, and allows simple visualization of results. Methodology/Principal findings The Loopamp Leishmania Detection Kit (Eiken Chemical Co., Japan), was evaluated in the diagnosis of VL in Sudan. A total of 198 VL suspects were tested by microscopy of lymph node aspirates (the reference test), direct agglutination test-DAT (in house production) and rK28 antigen-based rapid diagnostic test (OnSite Leishmania rK39-Plus, CTK Biotech, USA). LAMP was performed on peripheral blood (whole blood and buffy coat) previously processed by: i) a direct boil and spin method, and ii) the QIAamp DNA Mini Kit (QIAgen). Ninety seven of the VL suspects were confirmed as cases by microscopy of lymph node aspirates. The sensitivity and specificity for each of the tests were: rK28 RDT 98.81% and 100%; DAT 88.10% and 78.22%; LAMP-boil and spin 97.65% and 99.01%; LAMP-QIAgen 100% and 99.01%. Conclusions/Significance Due to its simplicity and high sensitivity, rK28 RDT can be used first in the diagnostic algorithm for primary VL diagnosis, the excellent performance of LAMP using peripheral blood indicates that it can be also included in the algorithm for diagnosis of VL as a simple test when parasitological confirmatory diagnosis is required in settings that are lower than the reference laboratory, avoiding the need for invasive lymph node aspiration. PMID:29444079
Killey, R; Mynors, C; Pearce, R; Nell, A; Prentis, A; Day, M J
2018-01-01
To determine the utility of an in-practice test kit to detect protective serum antibody against canine distemper virus, canine adenovirus and canine parvovirus type 2 in a sample of the UK dog population. Serum samples from 486 dogs, last vaccinated between less than 1 month and 124 months previously, were tested with the VacciCheck™ test kit for protective antibodies against distemper, adenovirus and parvovirus type 2. A high proportion of the dogs tested (93·6%) had protective antibody against all three of the core vaccine antigens: 95·7% of the dogs were seropositive against canine distemper virus, 97·3% against canine adenovirus and 98·5% against canine parvovirus type 2. The small number of dogs that were seronegative for one or more of the antigens (n = 31) may have had waning of previous serum antibody or may have been rare genetic non-responders to that specific antigen. UK veterinarians can be reassured that triennial revaccination of adult dogs with core vaccines provides long-lived protective immunity. In-practice serological test kits are a valuable tool for informing decision-making about canine core revaccination. © 2017 British Small Animal Veterinary Association.
Matsuo, Toshihiro; Miyagawa, Jun-Ichiro; Kusunoki, Yoshiki; Miuchi, Masayuki; Ikawa, Takashi; Akagami, Takafumi; Tokuda, Masaru; Katsuno, Tomoyuki; Kushida, Akira; Inagaki, Takashi; Namba, Mitsuyoshi
2016-05-01
The aims of the present study were to investigate the performance of a novel sandwich enzyme-linked immunosorbent assay (ELISA) for measuring glucagon (1-29) with monoclonal antibodies against both the C- and N-terminal regions of glucagon (1-29), and to analyze the differences in plasma levels and responses of glucagon (1-29) to oral glucose loading in normal glucose tolerance (NGT) subjects and patients with type 2 diabetes mellitus. The cross-reactivity against proglucagon fragments using the ELISA kit and two types of conventional radioimmunoassay (RIA) kits was evaluated. A 75-g oral glucose tolerance test was carried out with NGT subjects and patients with type 2 diabetes mellitus, and the glucagon (1-29) concentration was measured using three types of kit. The ELISA kit clearly had the lowest cross-reactivity against miniglucagon (19-29) and glicentin (1-61). The oral glucose tolerance test was carried out with 30 NGT and 17 patients with type 2 diabetes mellitus. The glucagon (1-29) levels measured by the ELISA kit after glucose loading were significantly higher at all time-points in the type 2 diabetes mellitus group than in the NGT group. However, the glucagon (1-29) levels measured by one RIA kit were significantly higher in the NGT group, and those measured with the other RIA kit were approximately the same among the groups. The novel sandwich ELISA accurately determines plasma glucagon (1-29) concentrations with much less cross-reactivity against other proglucagon fragments than conventional RIA kits.
Gaudin, Valérie; Rault, Annie; Hedou, Celine; Soumet, Christophe; Verdon, Eric
2017-09-01
Efficient screening methods are needed to control antibiotic residues in eggs. A microbiological kit (Explorer® 2.0 test (Zeu Inmunotech, Spain)) and an immunobiosensor kit (Microarray II (AM® II) on Evidence Investigator™ system (Randox, UK)) have been evaluated and validated for screening of antibiotic residues in eggs, according to the European decision EC/2002/657 and to the European guideline for the validation of screening methods. The e-reader™ system, a new automatic incubator/reading system, was coupled to the Explorer 2.0 test. The AM II kit can detect residues of six different families of antibiotics in different matrices including eggs. For both tests, a different liquid/liquid extraction of eggs had to be developed. Specificities of the Explorer 2.0 and AM II kit were equal to 8% and 0% respectively. The detection capabilities were determined for 19 antibiotics, with representatives from different families, for Explorer 2.0 and 12 antibiotics for the AM II kit. For the nine antibiotics having a maximum residue limit (MRL) in eggs, the detection capabilities CCβ of Explorer 2.0 were below the MRL for four antibiotics, equal to the MRL for two antibiotics and between 1 and 1.5 MRLs for the three remaining antibiotics (tetracyclines). For the antibiotics from other families, the detection capabilities were low for beta-lactams and sulfonamides and satisfactory for dihydrostreptomycin (DHS) and fluoroquinolones, which are usually difficult to detect with microbiological tests. The CCβ values of the AM II kit were much lower than the respective MRLs for three detected antibiotics (tetracycline, oxytetracycline, tylosin). Concerning the nine other antibiotics, the detection capabilities determined were low. The highest CCβ was obtained for streptomycin (100 µg kg -1 ).
Evaluation of HIV/AIDS diagnostics kits and formulation of a testing strategy for Pakistan.
Waheed, Usman; Hayat, Khizar; Ahmad, Bashir; Waheed, Yasir; Zaheer, Hasan Abbas
2013-04-01
Rapid diagnosis of HIV/AIDS enables the development of prevention and treatment programmes but accurate, reliable and cost effective testing strategies should be used for testing of HIV/AIDS from a large population. To evaluate the performance and effectiveness of three assays for the diagnosis of HIV in comparison with Western blot and to formulate an alternative cost-effective confirmatory approach for HIV diagnosis. 472 specimens (serum) from a Pakistani population were evaluated. Two rapid HIV testing kits (Capillus, SD Bioline) and one ELISA (Vironostika Ag/Ab) kit were used to detect HIV. Results were compared with Western blot against which sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of all HIV assays were assessed. 280/472 (59.3%) of the samples were positive for antibodies against purified HIV-1 viral proteins. The sensitivity of SD Bioline and Vironostika ELISA was 100% (95% CI; 98-100) while that of anti-HIV Capillus™ kit was 94.6% (95% CI; 91-96.8). The specificity of the Vironostika ELISA and anti-HIV Capillus™ kit was 100% (95% CI; 97-100) while specificity of SD Bioline was 98.4% (95% CI; 95-99). PPV was 100% (95% CI; 98-100%) for the anti-HIV Capillus™ and Vironostika ELISA and 98.9% (95% CI; 96-99%) for SD Bioline. NPV for SD Bioline and Vironostika ELISA was 100% (95% CI; 98-100%) and 92.7% for anti-HIV Capillus™ (95% CI; 88-96%). The sensitivity and specificity of all three kits were satisfactory compared to Western blot and could be used for effective diagnosis of HIV/AIDS in Pakistani population. Copyright © 2013 Elsevier B.V. All rights reserved.
3D vision upgrade kit for the TALON robot system
NASA Astrophysics Data System (ADS)
Bodenhamer, Andrew; Pettijohn, Bradley; Pezzaniti, J. Larry; Edmondson, Richard; Vaden, Justin; Hyatt, Brian; Morris, James; Chenault, David; Tchon, Joe; Barnidge, Tracy; Kaufman, Seth; Kingston, David; Newell, Scott
2010-02-01
In September 2009 the Fort Leonard Wood Field Element of the US Army Research Laboratory - Human Research and Engineering Directorate, in conjunction with Polaris Sensor Technologies and Concurrent Technologies Corporation, evaluated the objective performance benefits of Polaris' 3D vision upgrade kit for the TALON small unmanned ground vehicle (SUGV). This upgrade kit is a field-upgradable set of two stereo-cameras and a flat panel display, using only standard hardware, data and electrical connections existing on the TALON robot. Using both the 3D vision system and a standard 2D camera and display, ten active-duty Army Soldiers completed seven scenarios designed to be representative of missions performed by military SUGV operators. Mission time savings (6.5% to 32%) were found for six of the seven scenarios when using the 3D vision system. Operators were not only able to complete tasks quicker but, for six of seven scenarios, made fewer mistakes in their task execution. Subjective Soldier feedback was overwhelmingly in support of pursuing 3D vision systems, such as the one evaluated, for fielding to combat units.
van Geen, Alexander; Ahmed, Ershad B; Pitcher, Lynnette; Mey, Jacob L; Ahsan, Habibul; Graziano, Joseph H; Ahmed, Kazi Matin
2014-08-01
The arsenic (As) content of groundwater pumped from all tubewells within 61 contiguous villages of Araihazar, Bangladesh, was determined a first time in 2000-01 with laboratory measurements and a second time in 2012-13 using the ITS Arsenic Econo-Quick kit. The two surveys indicate that the total number of tubewells within the area almost doubled from 5560 to 10,879 over 12 years. The evolution of the distribution of well ages between the two surveys is consistent with a simple model that combines an annual increase of 42 wells/year in the rate of installations within the 61 villages starting in 1980 and a 7%/year rate of abandonment of wells as a function of well age. Colored placards were posted on each pumphead in 2012-13 on the basis of the kit results relative to the WHO guideline for As and the Bangladesh standard for As in drinking water: blue for As≤10 μg/L, green>10-50 μg/L, and red: >50 μg/L. According to quality-control samples collected from 502 tubewells for comparing the kit results with laboratory measurements, not a single well labeled blue in 2012-13 should have been labeled red and vice-versa. Field-kit testing in 2012-13 did not change the status of wells relative to the Bangladesh standard of 876 (87%) out of 1007 wells with a placard based on laboratory measurements in 2000-01 still attached to the pumphead. The high proportion of tubewells believed by households to be unsafe (66% out of 2041) that were still used for drinking and cooking in 2012-13 underlines the need for more widespread testing to identify low-As wells as an alternative source of drinking water. Copyright © 2013. Published by Elsevier B.V.
van Geen, Alexander; Sumon, Ershad B. A.; Pitcher, Lynnette; Mey, Jacob L.; Ahsan, Habibul; Graziano, Joseph H.; Ahmed, Kazi Matin
2014-01-01
The arsenic (As) content of groundwater pumped from all tubewells within 61 contiguous villages of Araihazar, Bangladesh, was determined a first time in 2000–01 with laboratory measurements and a second time in 2012–13 using the ITS Arsenic Econo-Quick kit. The two surveys indicate that the total number of tubewells within the area almost doubled from 5,560 to 10,879 over 12 years. The evolution of the distribution of well ages between the two surveys is consistent with a simple model that combines an annual increase of 42 wells/year in the rate of installations within the 61 villages starting in 1980 and a 7%/year rate of abandonment of wells as a function of well age. Colored placards were posted on each pumphead in 2012–2013 on the basis of the kit results relative to the WHO guideline for As and the Bangladesh standard for As in drinking water: blue for As ≤10 µg/L, green >10–50 µg/L, and red: >50 µg/L. According to quality-control samples collected from 502 tubewells for comparing the kit results with laboratory measurements, not a single well labeled blue in 2012–13 should have been labeled red and vice-versa. Field-kit testing in 2012–13 did not change the status of wells relative to the Bangladesh standard of 876 (87%) out of 1,007 wells with a placard based on laboratory measurements in 2000–01 still attached to the pumphead. The high proportion of tubewells believed by households to be unsafe (66% out of 2,041) that were still used for drinking and cooking in 2012–13 underlines the need for more widespread testing to identify low-As wells as an alternative source of drinking water. PMID:24438870
Effect of planecta and ROSE™ on the frequency characteristics of blood pressure-transducer kits.
Fujiwara, Shigeki; Kawakubo, Yoshifumi; Mori, Satoshi; Tachihara, Keiichi; Toyoguchi, Izumi; Yokoyama, Takeshi
2015-12-01
Pressure-transducer kits have frequency characteristics such as natural frequency and damping coefficient, which affect the monitoring accuracy. The aim of the present study was to investigate the effect of planecta ports and a damping device (ROSE™, Argon Medical Devices, TX, USA) on the frequency characteristics of pressure-transducer kits. The FloTrac sensor kit (Edwards Lifesciences, CA, USA) and the DTXplus transducer kit (Argon Medical Devices) were prepared with planecta ports, and their frequency characteristics were tested with or without ROSE™. The natural frequency and damping coefficient of each kit were obtained using frequency characteristics analysis software and evaluated by plotting them on the Gardner's chart. By inserting a planecta port, the natural frequency markedly decreased in both the FloTrac sensor kit (from 40 to 22 Hz) and the DTXplus transducer kit (from 35 to 22 Hz). In both kits with one planecta port, the damping coefficient markedly increased by insertion of ROSE™ from 0.2 to 0.5, optimising frequency characteristics. In both kits with two planecta ports, however, the natural frequency decreased from 22 to 12 Hz. The damping coefficient increased from 0.2 to 0.8 by insertion of ROSE™; however, optimisation was not achieved even by ROSE™ insertion. Planecta ports decrease the natural frequency of the kit. ROSE™ is useful to optimise the frequency characteristics in the kits without or with one planecta port. However, optimisation is difficult with two or more planecta ports, even with the ROSE™ device.
Kelvin, Elizabeth A; George, Gavin; Mwai, Eva; Nyaga, Eston; Mantell, Joanne E; Romo, Matthew L; Odhiambo, Jacob O; Starbuck, Lila; Govender, Kaymarlin
2018-01-01
We conducted a randomized controlled trial among 305 truck drivers from two North Star Alliance roadside wellness clinics in Kenya to see if offering HIV testing choices would increase HIV testing uptake. Participants were randomized to be offered (1) a provider-administered rapid blood (finger-prick) HIV test (i.e., standard of care [SOC]) or (2) a Choice between SOC or a self-administered oral rapid HIV test with provider supervision in the clinic. Participants in the Choice arm who refused HIV testing in the clinic were offered a test kit for home use with phone-based posttest counseling. We compared HIV test uptake using the Mantel Haenszel odds ratio (OR) adjusting for clinic. Those in the Choice arm had higher odds of HIV test uptake than those in the SOC arm (OR = 1.5), but the difference was not statistically significant (p = 0.189). When adding the option to take an HIV test kit for home use, the Choice arm had significantly greater odds of testing uptake (OR = 2.8, p = 0.002). Of those in the Choice arm who tested, 26.9% selected the SOC test, 64.6% chose supervised self-testing in the clinic, and 8.5% took a test kit for home use. Participants varied in the HIV test they selected when given choices. Importantly, when participants who refused HIV testing in the clinic were offered a test kit for home use, an additional 8.5% tested. Offering truck drivers a variety of HIV testing choices may increase HIV testing uptake in this key population.
SCDC Spanish Curricula Units. Social Science Strand, Unit 4, Grade Two, Teacher's Guide.
ERIC Educational Resources Information Center
Spanish Curricula Development Center, Miami Beach, FL.
The Spanish-English teacher's guide to unit four of the bilingual social science program for second grade students contains instructional activities to expand the child's conceptual field to the neighborhood. Kits 13-16 include assessment activities; each kit is to be used for two to three weeks. Focus, objective, and materials are listed for each…
Myers, Julie E; El-Sadr Davis, Olivia Y; Weinstein, Elliott R; Remch, Molly; Edelstein, Amy; Khawja, Amina; Schillinger, Julia A
2017-02-01
We conducted an in-person survey of New York City (NYC) pharmacies to assess the availability, accessibility, and price of the over-the-counter, rapid HIV self-test kit. NYC pharmacies were stratified into high, moderate and low morbidity neighborhoods by the HIV diagnosis rate of the neighborhood in which the pharmacy was located. A random sample of 500 pharmacies was taken [250 from high morbidity neighborhoods (HighMN) and 250 from low morbidity neighborhoods (LowMN)]. Pharmacies were excluded if: closed during survey, non-retail, or >10 min walk from subway. Project staff visited pharmacies to determine kit availability (in pharmacy on day of survey), accessibility (not locked/behind counter), and price (marked on shelf/product). Of 361 pharmacies (161 LowMN; 200 HighMN), kits were available in 27 % and accessible in 10 %; there was no difference by neighborhood. Kits were most often kept behind the pharmacy counter; this was more common in HighMN than in LowMN. Kits were kept solely behind the pharmacy counter in 52 %. Median price was US $42.99 without variability across neighborhoods. The rapid HIV self-test had limited availability and access in retail pharmacies. The high median price measured suggests that cost remained a barrier.
Home-based chlamydia testing of young people attending a music festival--who will pee and post?
Sacks-Davis, Rachel; Gold, Judy; Aitken, Campbell K; Hellard, Margaret E
2010-06-28
Chlamydia is most common among young people, but only a small proportion of Australian young people are tested annually. Home-based chlamydia testing has been piloted in several countries to increase testing rates, but uptake has been low. We aimed to identify predictors of uptake of home-based chlamydia testing to inform future testing programs. We offered home-based chlamydia testing kits to participants in a sexual behaviour cross-sectional survey conducted at a music festival in Melbourne, Australia. Those who consented received a testing kit and were asked to return their urine or vaginal swab sample via post. Nine hundred and two sexually active music festival attendees aged 16-29 completed the survey; 313 (35%) opted to receive chlamydia testing kits, and 67 of 313 (21%) returned a specimen for testing. One participant was infected with chlamydia (1% prevalence). Independent predictors of consenting to receive a testing kit included older age, knowing that chlamydia can make women infertile, reporting more than three lifetime sexual partners and inconsistent condom use. Independent predictors of returning a sample to the laboratory included knowing that chlamydia can be asymptomatic, not having had an STI test in the past six months and not living with parents. A low proportion of participants returned their chlamydia test, suggesting that this model is not ideal for reaching young people. Home-based chlamydia testing is most attractive to those who report engaging in sexual risk behaviours and are aware of the often asymptomatic nature and potential sequelae of chlamydia infection.
Home-based chlamydia testing of young people attending a music festival - who will pee and post?
2010-01-01
Background Chlamydia is most common among young people, but only a small proportion of Australian young people are tested annually. Home-based chlamydia testing has been piloted in several countries to increase testing rates, but uptake has been low. We aimed to identify predictors of uptake of home-based chlamydia testing to inform future testing programs. Methods We offered home-based chlamydia testing kits to participants in a sexual behaviour cross-sectional survey conducted at a music festival in Melbourne, Australia. Those who consented received a testing kit and were asked to return their urine or vaginal swab sample via post. Results Nine hundred and two sexually active music festival attendees aged 16-29 completed the survey; 313 (35%) opted to receive chlamydia testing kits, and 67 of 313 (21%) returned a specimen for testing. One participant was infected with chlamydia (1% prevalence). Independent predictors of consenting to receive a testing kit included older age, knowing that chlamydia can make women infertile, reporting more than three lifetime sexual partners and inconsistent condom use. Independent predictors of returning a sample to the laboratory included knowing that chlamydia can be asymptomatic, not having had an STI test in the past six months and not living with parents. Conclusions A low proportion of participants returned their chlamydia test, suggesting that this model is not ideal for reaching young people. Home-based chlamydia testing is most attractive to those who report engaging in sexual risk behaviours and are aware of the often asymptomatic nature and potential sequelae of chlamydia infection. PMID:20584287
Single-cell analysis of the fate of c-kit-positive bone marrow cells
NASA Astrophysics Data System (ADS)
Czarna, Anna; Sanada, Fumihiro; Matsuda, Alex; Kim, Junghyun; Signore, Sergio; Pereira, João D.; Sorrentino, Andrea; Kannappan, Ramaswamy; Cannatà, Antonio; Hosoda, Toru; Rota, Marcello; Crea, Filippo; Anversa, Piero; Leri, Annarosa
2017-10-01
The plasticity of c-kit-positive bone marrow cells (c-kit-BMCs) in tissues different from their organ of origin remains unclear. We tested the hypothesis that c-kit-BMCs are functionally heterogeneous and only a subgroup of these cells possesses cardiomyogenic potential. Population-based assays fall short of identifying the properties of individual stem cells, imposing on us the introduction of single cell-based approaches to track the fate of c-kit-BMCs in the injured heart; they included viral gene-tagging, multicolor clonal-marking and transcriptional profiling. Based on these strategies, we report that single mouse c-kit-BMCs expand clonally within the infarcted myocardium and differentiate into specialized cardiac cells. Newly-formed cardiomyocytes, endothelial cells, fibroblasts and c-kit-BMCs showed in their genome common sites of viral integration, providing strong evidence in favor of the plasticity of a subset of BMCs expressing the c-kit receptor. Similarly, individual c-kit-BMCs, which were infected with multicolor reporters and injected in infarcted hearts, formed cardiomyocytes and vascular cells organized in clusters of similarly colored cells. The uniform distribution of fluorescent proteins in groups of specialized cells documented the polyclonal nature of myocardial regeneration. The transcriptional profile of myogenic c-kit-BMCs and whole c-kit-BMCs was defined by RNA sequencing. Genes relevant for engraftment, survival, migration, and differentiation were enriched in myogenic c-kit-BMCs, a cell subtype which could not be assigned to a specific hematopoietic lineage. Collectively, our findings demonstrate that the bone marrow comprises a category of cardiomyogenic, vasculogenic and/or fibrogenic c-kit-positive cells and a category of c-kit-positive cells that retains an undifferentiated state within the damaged heart.
Single-cell analysis of the fate of c-kit-positive bone marrow cells.
Czarna, Anna; Sanada, Fumihiro; Matsuda, Alex; Kim, Junghyun; Signore, Sergio; Pereira, João D; Sorrentino, Andrea; Kannappan, Ramaswamy; Cannatà, Antonio; Hosoda, Toru; Rota, Marcello; Crea, Filippo; Anversa, Piero; Leri, Annarosa
2017-01-01
The plasticity of c-kit-positive bone marrow cells (c-kit-BMCs) in tissues different from their organ of origin remains unclear. We tested the hypothesis that c-kit-BMCs are functionally heterogeneous and only a subgroup of these cells possesses cardiomyogenic potential. Population-based assays fall short of identifying the properties of individual stem cells, imposing on us the introduction of single cell-based approaches to track the fate of c-kit-BMCs in the injured heart; they included viral gene-tagging, multicolor clonal-marking and transcriptional profiling. Based on these strategies, we report that single mouse c-kit-BMCs expand clonally within the infarcted myocardium and differentiate into specialized cardiac cells. Newly-formed cardiomyocytes, endothelial cells, fibroblasts and c-kit-BMCs showed in their genome common sites of viral integration, providing strong evidence in favor of the plasticity of a subset of BMCs expressing the c-kit receptor. Similarly, individual c-kit-BMCs, which were infected with multicolor reporters and injected in infarcted hearts, formed cardiomyocytes and vascular cells organized in clusters of similarly colored cells. The uniform distribution of fluorescent proteins in groups of specialized cells documented the polyclonal nature of myocardial regeneration. The transcriptional profile of myogenic c-kit-BMCs and whole c-kit-BMCs was defined by RNA sequencing. Genes relevant for engraftment, survival, migration, and differentiation were enriched in myogenic c-kit-BMCs, a cell subtype which could not be assigned to a specific hematopoietic lineage. Collectively, our findings demonstrate that the bone marrow comprises a category of cardiomyogenic, vasculogenic and/or fibrogenic c-kit-positive cells and a category of c-kit-positive cells that retains an undifferentiated state within the damaged heart.
Michelin, Birgit D. A.; Hadžisejdić, Ita; Bozic, Michael; Grahovac, Maja; Hess, Markus; Grahovac, Blaženka; Marth, Egon; Kessler, Harald H.
2008-01-01
Whole blood has been found to be a reliable matrix for the detection and quantitation of cytomegalovirus (CMV) DNA. In this study, the performance of the artus CMV LightCycler (LC) PCR kit in conjunction with automated sample preparation on a BioRobot EZ1 workstation was evaluated. The accuracy, linearity, analytical sensitivity, and inter- and intra-assay variations were determined. A total of 102 clinical EDTA whole-blood samples were investigated, and results were compared with those obtained with the in vitro diagnostics (IVD)/Conformité Européene (CE)-labeled CMV HHV6,7,8 R-gene quantification kit. When the accuracy of the new kit was tested, seven of eight results were found to be within ±0.5 log10 unit of the expected panel results. Determination of linearity resulted in a quasilinear curve over more than 5 log units. The lower limit of detection of the assay was determined to be 139 copies/ml in EDTA whole blood. The interassay variation ranged from 15 to 58%, and the intra-assay variation ranged from 7 to 35%. When clinical samples were tested and the results were compared with those of the routinely used IVD/CE-labeled assay, 53 samples tested positive and 13 samples tested negative by both of the assays. One sample was found to be positive with the artus CMV LC PCR kit only, and 35 samples tested positive with the routinely used assay only. The majority of discrepant results were found with low-titer samples. In conclusion, use of the artus CMV LC PCR kit in conjunction with automated sample preparation on the BioRobot EZ1 workstation may be suitable for the detection and quantitation of CMV DNA in EDTA whole blood in the routine low-throughput laboratory; however, low-positive results may be missed by this assay. PMID:18272703
Michelin, Birgit D A; Hadzisejdic, Ita; Bozic, Michael; Grahovac, Maja; Hess, Markus; Grahovac, Blazenka; Marth, Egon; Kessler, Harald H
2008-04-01
Whole blood has been found to be a reliable matrix for the detection and quantitation of cytomegalovirus (CMV) DNA. In this study, the performance of the artus CMV LightCycler (LC) PCR kit in conjunction with automated sample preparation on a BioRobot EZ1 workstation was evaluated. The accuracy, linearity, analytical sensitivity, and inter- and intra-assay variations were determined. A total of 102 clinical EDTA whole-blood samples were investigated, and results were compared with those obtained with the in vitro diagnostics (IVD)/Conformité Européene (CE)-labeled CMV HHV6,7,8 R-gene quantification kit. When the accuracy of the new kit was tested, seven of eight results were found to be within +/-0.5 log(10) unit of the expected panel results. Determination of linearity resulted in a quasilinear curve over more than 5 log units. The lower limit of detection of the assay was determined to be 139 copies/ml in EDTA whole blood. The interassay variation ranged from 15 to 58%, and the intra-assay variation ranged from 7 to 35%. When clinical samples were tested and the results were compared with those of the routinely used IVD/CE-labeled assay, 53 samples tested positive and 13 samples tested negative by both of the assays. One sample was found to be positive with the artus CMV LC PCR kit only, and 35 samples tested positive with the routinely used assay only. The majority of discrepant results were found with low-titer samples. In conclusion, use of the artus CMV LC PCR kit in conjunction with automated sample preparation on the BioRobot EZ1 workstation may be suitable for the detection and quantitation of CMV DNA in EDTA whole blood in the routine low-throughput laboratory; however, low-positive results may be missed by this assay.
A silent allele in the locus D5S818 contained within the PowerPlex®21 PCR Amplification Kit.
Chen, Ling; Tai, Yunchun; Qiu, Pingming; Du, Weian; Liu, Chao
2015-11-01
Three paternity tests cases were found with a single locus mismatch at the locus D5S818 with PowerPlex®21 PCR Amplification Kit (Promega). Forward and reverse primers were redesigned to type the samples again and to evaluate if there were alleles dropped out. The results showed the existence of a silent allele 12 in all the three families, due to a point mutation that changed cytosine to adenine at 90 nucleotides upstream from the 5' end of the AGAT repeat sequences in all the six individuals. A single locus mismatch due to a silent allele may occur in any locus using any kit. Therefore, we recommend using multiple kits to confirm the results in paternity testing cases with mismatches, especially when there is a single locus mismatch with homozygote involved. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Christy, Shannon M; Davis, Stacy N; Williams, Kimberly R; Zhao, Xiuhua; Govindaraju, Swapomthi K; Quinn, Gwendolyn P; Vadaparampil, Susan T; Lin, Hui-Yi; Sutton, Steven K; Roethzeim, Richard R; Shibata, David; Meade, Cathy D; Gwede, Clement K
2016-11-15
Intervention studies among individuals in diverse community settings are needed to reduce health disparities in colorectal cancer (CRC) screening and mortality rates. The current study compared the efficacy of 2 intervention conditions promoting CRC screening among black individuals. Black individuals ages 50 to 75 years (N = 330) were recruited in community settings in 4 Tampa Bay counties. After obtaining consent and conducting a baseline interview to assess sociodemographic and health-related variables, participants received either a culturally targeted CRC photonovella booklet plus a fecal immunochemical test (FIT) kit or a standard CRC screening brochure plus an FIT kit. The primary outcome was FIT kit screening uptake. FIT screening uptake at 6 months was 86.7% overall (90.3% in the brochure group and 81.9% in the photonovella group). Controlling for baseline between-group differences, there was no influence of intervention on FIT kit uptake (P = .756). Significant predictors of not returning an FIT kit included being unable to work (P = .010), having higher religious belief scores (P = .015), and living farther from the cancer center (P = .015). Providing FIT kits and educational print materials to black individuals in community settings resulted in high rates of CRC screening. The study also identified subgroups of participants who were less likely to return an FIT kit and provides insight for future interventions. Cancer 2016;122:3288-3296. © 2016 American Cancer Society. © 2016 American Cancer Society.
Evaluation of an enzyme immunoassay for detection of dengue virus NS1 antigen in human serum.
Dussart, Philippe; Labeau, Bhety; Lagathu, Gisèle; Louis, Philippe; Nunes, Marcio R T; Rodrigues, Sueli G; Storck-Herrmann, Cécile; Cesaire, Raymond; Morvan, Jacques; Flamand, Marie; Baril, Laurence
2006-11-01
We evaluated a one-step sandwich-format microplate enzyme immunoassay for detecting dengue virus NS1 antigen (Ag) in human serum by use of Platelia Dengue NS1 Ag kits (Bio-Rad Laboratories, Marnes La Coquette, France). We collected 299 serum samples from patients with dengue disease and 50 serum samples from patients not infected with dengue virus. For the 239 serum samples from patients with acute infections testing positive by reverse transcription-PCR and/or virus isolation for one of the four dengue virus serotypes, the sensitivity of the Platelia Dengue NS1 Ag kit was 88.7% (95% confidence interval, 84.0% to 92.4%). None of the serum samples from patients not infected with dengue virus tested positive with the Platelia Dengue NS1 Ag kit. A diagnostic strategy combining the Platelia Dengue NS1 Ag test for acute-phase sera and immunoglobulin M capture enzyme-linked immunosorbent assay for early-convalescent-phase sera increased sensitivity only from 88.7% to 91.9%. Thus, NS1 antigen detection with the Platelia Dengue NS1 Ag kit could be used for first-line testing for acute dengue virus infection in clinical diagnostic laboratories.
Ackermann-Gäumann, Rahel; Tritten, Marie-Lise; Hassan, Mona; Lienhard, Reto
2018-05-01
Tick-borne encephalitis (TBE) is endemic in many parts of Europe and Asia. The diagnosis of this disease is essentially based on the demonstration of specific antibodies. For reasons of simplicity, automatization and quick availability of test results, enzyme-linked immunosorbent assays (ELISAs) are the method of choice for serological diagnosis of TBE. Here, we evaluated three commercially available anti-TBEV IgG and IgM ELISAs using 251 serum samples: the SERION ELISA classic FSME Virus/TBE Virus IgG and IgM kit (Virion\\Serion), the RIDASCREEN ® FSME/TBE IgG and IgM kit (R-Biopharm), and the anti-FSME/TBE virus ELISA "Vienna" IgG/anti-FSME/TBE virus ELISA IgM kit (Euroimmun). In total, discrepant test results for IgG and/or IgM were observed for 37/251 (14.7 %) of tested samples; differences were statistically significant. Reference values defined by serum neutralization test (SNT, n = 25) or results provided by EQA organizers (n = 2) were established for a subset of samples. In relation to these values, false-positive results were observed mainly for Euroimmun Vienna IgG and RIDASCREEN IgG, whereas false-negative results were primarily observed for Virion\\Serion IgG and RIDASCREEN IgM kits. In routine diagnostics, specificity problems are of major relevance and may be addressed by analyzing the respective samples using SNT. Copyright © 2018 Elsevier GmbH. All rights reserved.
Development and clinical evaluation of a rapid diagnostic kit for feline leukemia virus infection.
Kim, Won-Shik; Chong, Chom-Kyu; Kim, Hak-Yong; Lee, Gyu-Cheol; Jeong, Wooseog; An, Dong-Jun; Jeoung, Hye-Young; Lee, Jae-In; Lee, Young-Ki
2014-01-01
Feline leukemia virus (FeLV) causes a range of neoplastic and degenerative diseases in cats. To obtain a more sensitive and convenient diagnosis of the disease, we prepared monoclonal antibodies specific for the FeLV p27 to develop a rapid diagnostic test with enhanced sensitivity and specificity. Among these antibodies, we identified two clones (hybridomas 8F8B5 and 8G7D1) that specifically bound to FeLV and were very suitable for a diagnostic kit. The affinity constants for 8F8B5 and 8G7D1 were 0.35 × 10⁸ and 0.86 × 10⁸, respectively. To investigate the diagnostic abilities of the rapid kit using these antibodies, we performed several clinical studies. Assessment of analytical sensitivity revealed that the detection threshold of the rapid diagnostic test was 2 ng/mL for recombinant p27 and 12.5 × 10⁴ IU/mL for FeLV. When evaluating 252 cat sera samples, the kit was found to have a kappa value of 0.88 compared to polymerase chain reaction (PCR), indicating a significant correlation between data from the rapid diagnostic test and PCR. Sensitivity and specificity of the kit were 95.2% (20/21) and 98.5% (257/261), respectively. Our results demonstrated that the rapid diagnostic test would be a suitable diagnostic tool for the rapid detection of FeLV infection in cats.
[Forensic Application of HuaxiaTM Platinum Kit].
Wang, Y L; Sheng, X; Li, M; Chen, Y L; Lin, Y; Chen, L Q
2017-04-01
To investigate the genetic polymorphism of 23 autosomal STR loci of Huaxia™ Platinum kit in Chinese Han population, and to evaluate the forensic efficiency of Huaxia™ Platinum kit. A total of 500 unrelated healthy individuals from Han population were genotyped with Huaxia™ Platinum kit. The frequency distribution and the parameter of population genetics of STR loci were analysed statistically. Huaxia™ Platinum kit was compared with other 7 commercial STR kits commonly seen at home and abroad in the number of STR loci, interior label, fluorescent mark, total number of alleles in Ladder and system effectiveness. All the 23 autosomal STR loci were consistent with Hardy-Weinberg equilibrium ( P >0.05). The discrimination power was 0.791 5-0.986 2. The polymorphism information content (PIC) was 0.559 0-0.914 0. The combined discrimination power (CDP) was 1-4.1×10⁻²⁸, while combined probability of paternity exclusion in trio (CPET) and in duo (CPED) were 1-4.1×10⁻¹⁰ and 1-8.4×10⁻⁷, respectively. Compared with other 7 kits, Huaxia™ Platinum kit contained the most number of alleles within the Ladder. All the 23 autosomal STR loci of Huaxia™ Platinum kit with highly polymorphic in Han population can be used for paternity testing and individual identification. Compared with other 7 kits, it appears that Huaxia™ Platinum kit can provide more genetic information. Copyright© by the Editorial Department of Journal of Forensic Medicine
Iddawela, D; Ehambaram, K; Kumarasiri, P V; Wijesundera, S
2015-09-01
ELISA is the most widely used form of diagnosis for toxoplasmosis. Several commercial kits are currently used in Sri Lanka. However, these kits are not affordable in resource-limited settings. Objectives Aim of this study was to develop a cost effective in-house ELISA for the detection of Toxoplasma antibody and to estimate the diagnostic accuracy compared to a commercial kit. Vero cell lines were inoculated with tachyzoites and harvested after 2-6 days and sonicated to obtain somatic antigen. The antigen was used as coating material in ELISA to detect antibodies against T. gondii in patient sera. Hundred and three patients' sera were analysed by in-house ELISA and kit ELISA. Optical density (OD) values were analysed statistically. Toxoplasma IgG avidity test was used to determine the chronic and acute phase of infection. The optimum working dilutions for antigen was 0.846 μg/ml and for serum 1 in 100. The optimal cut-off values for the in-house ELISA within the range 0.85 to 0.98 at which the sensitivity was 95.3% and specificity was 98.3. The OD values of in-house ELISA were compared with OD values of kit ELISA and the results showed strong correlation between the two tests. The results of our study demonstrated that our in-house ELISA for detection of T. gondii antibody was as sensitive and specific as the commercial kit used in this study. Thus, the in-house ELISA is a useful, costeffective tool for diagnostic and screening purposes.
Field evaluation of a rapid diagnostic test to detect antibodies in human toxocariasis.
Lim, P K C; Yamasaki, H; Mak, J W; Wong, S F; Chong, C W; Yap, I K S; Ambu, S; Kumarasamy, V
2015-08-01
Human toxocariasis which is caused mainly by the larvae of Toxocara canis and Toxocara cati, is a worldwide zoonotic disease that can be a potentially serious human infection. The enzyme-linked immunosorbent assay (ELISA) using T. canis excretory-secretory (TES) antigens harvested from T. canis larvae is currently the serological test for confirming toxocariasis. An alternative to producing large amounts of Toxocara TES and improved diagnosis for toxocariasis is through the development of highly specific recombinant antigens such as the T. canis second stage larva excretory-secretory 30 kDa protein (recTES-30). The aim of this study was to evaluate the sensitivity and specificity of a rapid diagnostic kit (RDT, named as iToxocara kit) in comparison to recTES-30 ELISA in Serendah Orang Asli village in Selangor, Malaysia. A total of 133 subjects were included in the study. The overall prevalence rates by ELISA and RDT were 29.3% and 33.1%, respectively, with more positive cases detected in males than females. However, no association was found between toxocariasis and gender or age. The percentage sensitivity, specificity, positive predictive value and negative predictive value of RDT were 85.7%, 90.1%, 80% and 93.2%, respectively. The prevalence for toxocariasis in this population using both ELISA and RDT was 27.1% (36/133) and the K-concordance test suggested good agreement of the two tests with a Cohen's kappa of 0.722, P<0.01. In addition, the followed-up Spearman rank correlation showed a moderately high correlation at R=0.704 and P<0.01. In conclusion, the RDT kit was faster and easier to use than an ELISA and is useful for the laboratory diagnosis of hospitalized cases of toxocariasis. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.
Effectiveness of a multimedia outreach kit for families of wounded veterans.
Walker, David Ian; Cardin, Jean-François; Chawla, Neelu; Topp, David; Burton, Thomaseo; Macdermid Wadsworth, Shelley
2014-04-01
Young children in military families with a member who has a life changing injury can experience emotional difficulties and behavior changes. This study evaluated a Sesame Workshop multimedia kit called: Talk, Listen, Connect: Changes (TLC-II(C); 2008). The kit, which included video and print materials, aimed to help caregivers (i.e., at-home partner, at-home relative or family member of a current or discharged military member) assist young children as they adjusted to their parent's injury. We expected that the materials would be used and their quality evaluated. We hypothesized that use of the materials would produce improvements in caregiver and child outcomes as well as reductions in perceptions of disruption in the home. We also predicted that kit-use would have a positive impact on the family. One-hundred and fifty three families with children aged 2-8 years were randomly assigned to receive the kit being evaluated (TLC-II(C)) or a control kit (Healthy Habits for Life (HHL)), also developed by Sesame Workshop. Group outcomes were compared four weeks following receipt of the kits using multivariate analysis of variance. All materials were well used and highly rated. All caregivers reported less social isolation, less child aggression, and significantly less disruptive home environments after kit use. Test group caregivers reported significantly greater reductions in depressive symptoms and significant increases in children's social competence over time in comparison to the control group. These results signal important improvements among families as a consequence of using either test or control materials. As a preventative intervention designed for families with an injured member, TLC-II(C) was particularly effective at improving coping. Copyright © 2014 Elsevier Inc. All rights reserved.
Evaluation of a Commercial Field Test to Detect African Swine Fever.
Cappai, Stefano; Loi, Federica; Coccollone, Annamaria; Cocco, Manuele; Falconi, Caterina; Dettori, Giovanna; Feliziani, Francesco; Sanna, Maria Luisa; Oggiano, Annalisa; Rolesu, Sandro
2017-07-01
African swine fever (ASF) is one of the most important and complex infectious diseases affecting pigs ( Sus scrofa ). The disease has been present in Sardinia, Italy, since 1978. Factors influencing the presence of the disease on the island are the presence of illegally bred pigs, uncontrolled movements of animals, and local traditions. Implementation of public health programs is essential for controlling ASF. The use of new diagnostic techniques on both wild boar (WB) and illegally bred pigs would provide tools for faster and more inexpensive control of the disease. We evaluated a commercial serological test kit (Pen-side [PS]) for use in the field. We sampled 113 hunter-harvested WB during the 2014-15 season, collecting blood and lung samples to conduct serological analyses and to screen for the ASF virus. Although the sensitivity (81.8%) and specificity (95.9%) of tests performed in the field were reduced compared to the same test in laboratory, they nevertheless allowed for rapid diagnosis and reduced unnecessary carcass destruction. The test, conducted in the field, was less expensive than in the laboratory and required less manpower. Therefore, we conclude that the combined use of antibody PS test and antigen PS test may be a valuable emergency management method during an outbreak as well as a useful tool for conducting regular monitoring activities as a preventive policy.
Evaluation of four commercial quantitative real-time PCR kits with inhibited and degraded samples.
Holmes, Amy S; Houston, Rachel; Elwick, Kyleen; Gangitano, David; Hughes-Stamm, Sheree
2018-05-01
DNA quantification is a vital step in forensic DNA analysis to determine the optimal input amount for DNA typing. A quantitative real-time polymerase chain reaction (qPCR) assay that can predict DNA degradation or inhibitors present in the sample prior to DNA amplification could aid forensic laboratories in creating a more streamlined and efficient workflow. This study compares the results from four commercial qPCR kits: (1) Investigator® Quantiplex® Pro Kit, (2) Quantifiler® Trio DNA Quantification Kit, (3) PowerQuant® System, and (4) InnoQuant® HY with high molecular weight DNA, low template samples, degraded samples, and DNA spiked with various inhibitors.The results of this study indicate that all kits were comparable in accurately predicting quantities of high quality DNA down to the sub-picogram level. However, the InnoQuant(R) HY kit showed the highest precision across the DNA concentration range tested in this study. In addition, all kits performed similarly with low concentrations of forensically relevant PCR inhibitors. However, in general, the Investigator® Quantiplex® Pro Kit was the most tolerant kit to inhibitors and provided the most accurate quantification results with higher concentrations of inhibitors (except with salt). PowerQuant® and InnoQuant® HY were the most sensitive to inhibitors, but they did indicate significant levels of PCR inhibition. When quantifying degraded samples, each kit provided different degradation indices (DI), with Investigator® Quantiplex® Pro indicating the largest DI and Quantifiler® Trio indicating the smallest DI. When the qPCR kits were paired with their respective STR kit to genotype highly degraded samples, the Investigator® 24plex QS and GlobalFiler® kits generated more complete profiles when the small target concentrations were used for calculating input amount.
Ford installs a UBNT sensor kit in the U.S. Laboratory
2013-01-16
ISS034-E-030216 (16 Jan. 2013) --- NASA astronaut Kevin Ford, Expedition 34 commander, installs a Ultra-Sonic Background Noise Tests (UBNT) sensor kit behind a rack in the Destiny of the International Space Station.
Ford installs a UBNT sensor kit in the U.S. Laboratory
2013-01-16
ISS034-E-030218 (16 Jan. 2013) --- NASA astronaut Kevin Ford, Expedition 34 commander, installs a Ultra-Sonic Background Noise Tests (UBNT) sensor kit behind a rack in the Destiny of the International Space Station.
Leontiou, Chrysanthia A.; Hadjidaniel, Michael D.; Mina, Petros; Antoniou, Pavlos; Ioannides, Marios; Patsalis, Philippos C.
2015-01-01
Introduction Epigenetic alterations, including DNA methylation, play an important role in the regulation of gene expression. Several methods exist for evaluating DNA methylation, but bisulfite sequencing remains the gold standard by which base-pair resolution of CpG methylation is achieved. The challenge of the method is that the desired outcome (conversion of unmethylated cytosines) positively correlates with the undesired side effects (DNA degradation and inappropriate conversion), thus several commercial kits try to adjust a balance between the two. The aim of this study was to compare the performance of four bisulfite conversion kits [Premium Bisulfite kit (Diagenode), EpiTect Bisulfite kit (Qiagen), MethylEdge Bisulfite Conversion System (Promega) and BisulFlash DNA Modification kit (Epigentek)] regarding conversion efficiency, DNA degradation and conversion specificity. Methods Performance was tested by combining fully methylated and fully unmethylated λ-DNA controls in a series of spikes by means of Sanger sequencing (0%, 25%, 50% and 100% methylated spikes) and Next-Generation Sequencing (0%, 3%, 5%, 7%, 10%, 25%, 50% and 100% methylated spikes). We also studied the methylation status of two of our previously published differentially methylated regions (DMRs) at base resolution by using spikes of chorionic villus sample in whole blood. Results The kits studied showed different but comparable results regarding DNA degradation, conversion efficiency and conversion specificity. However, the best performance was observed with the MethylEdge Bisulfite Conversion System (Promega) followed by the Premium Bisulfite kit (Diagenode). The DMRs, EP6 and EP10, were confirmed to be hypermethylated in the CVS and hypomethylated in whole blood. Conclusion Our findings indicate that the MethylEdge Bisulfite Conversion System (Promega) was shown to have the best performance among the kits. In addition, the methylation level of two of our DMRs, EP6 and EP10, was confirmed. Finally, we showed that bisulfite amplicon sequencing is a suitable approach for methylation analysis of targeted regions. PMID:26247357
Leontiou, Chrysanthia A; Hadjidaniel, Michael D; Mina, Petros; Antoniou, Pavlos; Ioannides, Marios; Patsalis, Philippos C
2015-01-01
Epigenetic alterations, including DNA methylation, play an important role in the regulation of gene expression. Several methods exist for evaluating DNA methylation, but bisulfite sequencing remains the gold standard by which base-pair resolution of CpG methylation is achieved. The challenge of the method is that the desired outcome (conversion of unmethylated cytosines) positively correlates with the undesired side effects (DNA degradation and inappropriate conversion), thus several commercial kits try to adjust a balance between the two. The aim of this study was to compare the performance of four bisulfite conversion kits [Premium Bisulfite kit (Diagenode), EpiTect Bisulfite kit (Qiagen), MethylEdge Bisulfite Conversion System (Promega) and BisulFlash DNA Modification kit (Epigentek)] regarding conversion efficiency, DNA degradation and conversion specificity. Performance was tested by combining fully methylated and fully unmethylated λ-DNA controls in a series of spikes by means of Sanger sequencing (0%, 25%, 50% and 100% methylated spikes) and Next-Generation Sequencing (0%, 3%, 5%, 7%, 10%, 25%, 50% and 100% methylated spikes). We also studied the methylation status of two of our previously published differentially methylated regions (DMRs) at base resolution by using spikes of chorionic villus sample in whole blood. The kits studied showed different but comparable results regarding DNA degradation, conversion efficiency and conversion specificity. However, the best performance was observed with the MethylEdge Bisulfite Conversion System (Promega) followed by the Premium Bisulfite kit (Diagenode). The DMRs, EP6 and EP10, were confirmed to be hypermethylated in the CVS and hypomethylated in whole blood. Our findings indicate that the MethylEdge Bisulfite Conversion System (Promega) was shown to have the best performance among the kits. In addition, the methylation level of two of our DMRs, EP6 and EP10, was confirmed. Finally, we showed that bisulfite amplicon sequencing is a suitable approach for methylation analysis of targeted regions.
Zhang, L; Jin, C; Jiang, Z; Tang, T; Jiang, Y; Pan, P L
2017-09-10
Objective: To compare the bio-equivalence among commercial HIV-1 viral load tests, including EasyQ HIV-1 v2.0 (EasyQ) from bioMerieux NucliSens of France; VERSANT HIV-1 RNA 3.0 assay (bDNA) from Siemens Healthcare Diagnostics of USA; COBAS AmpliPrep/COBAS TaqMan HIV-1 test (Taqman) from Roche Molecular Diagnosis of USA; Abbott Real Time HIV-1 Kit (M2000) from Abbott Molecular of USA and two domestic HIV-1 viral load test kits (domestic kit) from DaAn Gene Company of Sun Yat-Sen University and Liaoning Bio-Pharmaceutical company of Northeast pharmaceutical group, by using proficiency test results in China from 2013 to 2015. Methods: A total of 2 954 proficiency test results, obtained from 22 positive samples of 6 proficiency tests in 155 laboratories conducted by China CDC were analyzed during 2013-2015. The results from each sample were first logarithmic transformed and then grouped according to the method used, the mean value of logarithmic results was calculated. Subsequently, 22 clusters of mean values were analyzed by Bland-Altman analysis for the consistency, and linear regression analysis for the interdependency. Results: The results indicated that, by taking Taqman as the reference, EasyQ, M2000, bDNA and domestic kit had good consistency (90 % -100 % ) and interdependency. Conclusion: All the viral load tests were bio-equivalent. Moreover, according to the conversion formula derived from domestic proficiency test results, all the viral load results could be converted, which is critical for epidemiological analysis.
Usability testing of a Falls Prevention Tool Kit for an inpatient acute care setting.
Goldsmith, Denise; Zuyev, Lyubov; Benoit, Angie; Chang, Frank Y; Horsky, Jan; Dykes, Patricia
2009-01-01
Efforts to prevent falls in the hospital setting involves identifying patients at risk of falling and implementing fall prevention strategies. This poster describes the method and results of Performance Usability Testing on a web-based Fall Prevention Tool Kit (FPTK) developed as part of a research study, (Falls TIPS-Tailoring Interventions for Patient Safety) funded by The Robert Wood Johnson Foundation.
Hydrogen Technology and Energy Curriculum (HyTEC)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nagle, Barbara
The Lawrence Hall of Science of the University of California, Berkeley has collaborated with scientists and engineers, a local transit agency, school districts, and a commercial curriculum publisher to develop, field-test nationally, and publish a two-week curriculum module on hydrogen and fuel cells for high school science. Key partners in this project are the Schatz Energy Research Center (SERC) of Humboldt State University, the Alameda-Contra Costa Transit District (AC Transit), FilmSight Productions, Lab-Aids, Inc., and 32 teachers and 2,370 students in field-test classrooms in California, Connecticut, Ohio, New York, South Carolina, and Washington. Field-test teachers received two to three daysmore » of professional development before teaching the curriculum and providing feedback used for revision of the curriculum. The curriculum, titled Investigating Alternative Energy: Hydrogen and Fuel Cells and published by Lab-Aids, Inc., includes a teachers guide (with lesson plans, resources, and student handout pages), two interactive computer animations, a video, a website, and a laboratory materials kit. The project has been disseminated to over 950 teachers through awareness workshops at state, regional, and national science teacher conferences.« less
Beynon, C M; Sumnall, H R; McVeigh, J; Cole, J C; Bellis, M A
2006-10-01
Assessment of the sensitivity and specificity of two commercially available 'drug-facilitated sexual assault' drug detector kits, Drink Guard and Drink Detective. Experimental. Laboratory. Gamma hydroxybutyrate (GHB) sodium salt, ketamine hydrochloride, temazepam, flunitrazepam and diazepam were dissolved (Tween added to benzodiazepine solutions) as separate stock solutions and added to 330 ml samples of cola (Pepsi Max), beer (Stella Artois), 'alcopop' (Bacardi Breezer) and placebo (distilled water). The doses used are reported to be common in cases of intoxication. Each kit was tested 10 times for each drink/drug combination. Two blind, independent observers scored each test (presence/absence of drug) in accordance with kit instructions; chi 2 was used to compare the proportion of times raters scored tests correctly and incorrectly. Sensitivity and specificity were calculated overall, for each drink, and sensitivity was calculated for each drug. Inter-observer agreement was evaluated using the kappa statistic. While both raters were able to score significantly more tests correctly than incorrectly using Drink Detective, and one rater scored similarly using Drink Guard, the overall sensitivity of Drink Detective and Drink Guard was 69.0% (95% CI 64.2-73.5%) and 37.5% (95% CI 30.1-45.5%), respectively. Sensitivity was drink-dependent. Drink Detective was unable to detect our dose of GHB in water, with all tests scored negatively by both raters for this drink/drug combination (n = 20 negative scores). Overall, specificity was 76.6% (95% CI 71.5-81.0%) and 87.9% (95% CI 83.0-91.6%) for Drink Guard and Drink Detective, respectively, but was affected by the beverage. Inter-rater agreement was poor for Drink Guard (kappa = 0.278 +/- 0.069) but excellent for Drink Detective (kappa = 0.894 +/- 0.245). Inter-observer agreement was drug-dependent. Use of drug detector kits by the public in the night-time environment needs further investigation and may create a false sense of security (false negatives) and undue concern (false positives) among kit users.
NASA Astrophysics Data System (ADS)
Lang, A.; Wesely, N.; Soós, B.; Sléber, B.; Majnovics, Z.; Ettingshausen, M.; Bodnár, L.; Németh, A.; Roos, M.
2011-10-01
In our school works a course in robotics where students build and program robots from a LEGO MINDSTORMS kit. We took part in the Hunveyor- Husar project with a Mars rover based on a rover model kit, of which the operating arms are built out of LEGO and controlled by an MINDSTORMS NXT computer. We presented our rover on the EPSC in Rome last September 2010 We presented our rover on the EPSC in Rome in September 2010. At that same conference the "Rosetta's Comet Touchdown" educational kit was officially presented. We were very interested and in conversation with the people from the project, we agreed that our school in Sopron would also participate in testing the kit. . The kit comes with a set of Interdisciplinary Activity Sheets (IAS, downloadable from Vimeo channel1) and a great feature is that the proposed activities in the IAS cover three areas: science, art/history and engineering. The 31 students from our class divided up in groups and each group chose a different topic: History of comets in Hungarian culture; Designing a T-shirt; Research on comets; Hungary in the Rosetta mission; Animation of Rosetta's orbit in space; building a LEGO MINDSTORM model; a film was made of the activities . In this presentation we report in particular the activities of the LEGO building team.
Exploration of the assessment practices of elementary teachers using science kits
NASA Astrophysics Data System (ADS)
Scribner-Maclean, Michelle
The purpose of the study was to determine the assessment literacy levels of elementary teachers who are experienced science kit users compared to those who are novice users as well as to compare assessment literacy levels of kit users to non kit users. Further, the study explored how teachers used assessment instruments in a classroom setting during kit-based science lessons. The study consisted of two parts. The population for Part One of this study was 47 elementary teachers from four communities in Northeastern Massachusetts who used Science, Technology, and Children (STC) kits for their classroom science instruction. Part Two of this study was conducted with four elementary teachers, two experienced kit users and two novice kit users, who were selected by their administrators. Data were collected for Part One of this study by use of the Teacher Assessment Questionnaire (TAQ), developed by Plake and Impara (1990), which provided a description of the assessment literacy levels of teachers. The assessment literacy levels of experienced kit users were compared to novice kit users by the t-Test for independent means. The assessment literacy levels of kit users and non kit users were also compared by use of the t-Test for independent means. For Part Two, classroom observations and teacher interviews were audio taped and transcribed. Each of these four teachers were also given the TAQ. Data for Part Two of the study were categorized and coded by Whittington's (1990) assessment literacy skills which are based upon the Standards for Teacher Competency of Educational Assessment of Students (STCEAS). Instances in which these skills occurred during classroom observations and pre- and post-lesson interviews were tabulated to create an overall picture of assessment literacy for each of the four teachers. The findings for Parts One and Two of this study indicate that there were differences in the assessment literacy scores for kit users and non kit users only for Standard Two: Developing Assessment Methods Appropriate for Instructional Decisions and Standard Seven: Recognizing Unethical, Illegal, and Otherwise Inappropriate Assessment Methods a significant difference between the assessment literacy scores of kit users and non kit users. There were no differences between novice and experienced kit users. Nor were there a highly significant overall difference between the skills displayed in the classrooms of experienced and novice kit users. Part, Two of this study further indicates that, although teachers correctly answered the majority of the items on the TAQ, observations of classroom practice did not show evidence that teachers demonstrate understanding of assessment on a regular basis. The assessment reform movement puts strong emphasis on the quality of assessment instruments as well the knowledge of those who use assessment. Effective assessment is strongly linked to effective overall teaching. Science curriculum that has a strong content base cannot help increase scientific literacy without a strong assessment component administered by teachers and administrators who are competent assessors. This study makes a case for schools which introduce new science curriculum units to provide educators with on-going training in assessment as well as in use of the curriculum. The evidence provided by this study indicates that experience using the assessments in kits is not enough to enable teachers to become assessment literate.
ERIC Educational Resources Information Center
Sarmiento, Kelly; Mitchko, Jane; Klein, Cynthia; Wong, Sharon
2010-01-01
Background: To reduce the number of sports-related concussions, the Centers for Disease Control and Prevention (CDC), with the support of partners and experts in the field, has developed a tool kit for high school coaches with practical, easy-to-use concussion-related information. This study explores the success of the tool kit in changing…
TECHNOLOGIES FOR MONITORING AND MEASUREMENT ...
A demonstration of technologies for determining the presence of dioxin and dioxin-like compounds in soil and sediment was conducted under EPA's Superfund Innovative Technology Evaluation Program in Saginaw, Michigan in April 2004. This report describes the performance evaluation of CAPE Technologies DF-1 Dioxin/Furan and PCB TEQ Immunoassay Kits. The kits are immunoassay techniques that report the total toxicity equivalents (TEQ) of dioxin/furans and polychlorinated biphenyls (PCBs. The technology results were compared to high resolution mass spectrometry TEQ results generated using EPA Methods 1613B and 1668A.The CAPE Technologies kits generally reported data higher than the certified PE and reference laboratory values. The technologys estimated MDL was 12 to 33 pg/g TEQ. Results from this demonstration suggest that the CAPE Technologies kits could be an effective screening tool for determining sample results above and below 20 pg/g TEQ and even more effective as a screen for sample above and below 50 pg/g TEQ, particularly considering that both the cost ($59,234 vs. $398,029) and the time (3 weeks vs. 8 months) to analyze the 209 demonstration samples were significantly less than those of the reference laboratory. The objective of this program is to promote the acceptance and use of innovative field technologies by providing well-documented performance and cost data obtained from field demonstrations.
Elwick, Kyleen; Mayes, Carrie; Hughes-Stamm, Sheree
2018-05-01
In cases such as mass disasters or missing persons, human remains are challenging to identify as they may be fragmented, burnt, been buried, decomposed, and/or contain inhibitory substances. This study compares the performance of a relatively new STR kit in the US market (Investigator® 24plex QS kit; Qiagen) with the GlobalFiler® PCR Amplification kit (Thermo Fisher Scientific) when genotyping highly inhibited and low level DNA samples. In this study, DNA samples ranging from 1 ng to 7.8 pg were amplified to define the sensitivity of two systems. In addition, DNA (1 ng and 0.1 ng input amounts) was spiked with various concentrations of five inhibitors common to human remains (humic acid, melanin, hematin, collagen, calcium). Furthermore, bone (N = 5) and tissue samples from decomposed human remains (N = 6) were used as mock casework samples for comparative analysis with both STR kits. The data suggest that the GlobalFiler® kit may be slightly more sensitive than the Investigator® kit. On average STR profiles appeared to be more balanced and average peak heights were higher when using the GlobalFiler® kit. However, the data also show that the Investigator® kit may be more tolerant to common PCR inhibitors. While both STR kits showed a decrease in alleles as the inhibitor concentration increased, more complete profiles were obtained when the Investigator® kit was used. Of the 11 bone and decomposed tissue samples tested, 8 resulted in more complete and balanced STR profiles when amplified with the GlobalFiler® kit. Copyright © 2018 Elsevier B.V. All rights reserved.
c-kit expression profile and regulatory factors during spermatogonial stem cell differentiation
2013-01-01
Background It has been proven that c-kit is crucial for proliferation, migration, survival and maturation of spermatogenic cells. A periodic expression of c-kit is observed from primordial germ cells (PGCs) to spermatogenetic stem cells (SSCs), However, the expression profile of c-kit during the entire spermatogenesis process is still unclear. This study aims to reveal and compare c-kit expression profiles in the SSCs before and after the anticipated differentiation, as well as to examine its relationship with retinoic acid (RA) stimulation. Results We have found that there are more than 4 transcripts of c-kit expressed in the cell lines and in the testes. The transcripts can be divided into short and long categories. The long transcripts include the full-length canonical c-kit transcript and the 3′ end short transcript. Short transcripts include the 3.4 kb short transcript and several truncated transcripts (1.9-3.2 kb). In addition, the 3.4 kb transcript (starting from intron 9 and covering exons 10 ~ 21) is discovered to be specifically expressed in the spermatogonia. The extracellular domain of Kit is obtained in the spermatogonia stage, but the intracellular domain (50 kDa) is constantly expressed in both SSCs and spermatogonia. The c-kit expression profiles in the testis and the spermatogonial stem cell lines vary after RA stimulation. The wave-like changes of the quantitative expression pattern of c-kit (increase initially and decrease afterwards) during the induction process are similar to that of the in vivo male germ cell development process. Conclusions There are dynamic transcription and translation changes of c-kit before and after SSCs’ anticipated differentiation and most importantly, RA is a significant upstream regulatory factor for c-kit expression. PMID:24161026
Li, Chuan; Matsushita, Satoshi; Li, Zhengqing; Guan, Jianjun; Amano, Atsushi
2017-10-01
Resident cardiac stem cells are expected to be a therapeutic option for patients who suffer from severe heart failure. However, uncertainty remains over whether sorting cells for c-kit, a stem cell marker, improves therapeutic outcomes. Cardiac outgrowth cells cultured from explants of rat heart atrium were sorted according to their positivity (+) or negativity (-) for c-kit. These cells were exposed to hypoxia for 3 d, and subsequently harvested for mRNA expression measurement. The cell medium was also collected to assess cytokine secretion. To test for a functional benefit in animals, myocardial infarction (MI) was induced in rats, and c-kit+ or c-kit- cells were injected. The left ventricular ejection fraction (LVEF) was measured for up to 4 weeks, after which the heart was harvested for biological and histological analyses. Expression of the angiogenesis-related genes, VEGF and ANGPTL2, was significantly higher in c-kit+ cells after 3 d of hypoxic culture, although we found no such difference prior to hypoxia. Secretion of VEGF and ANGPTL2 was greater in the c-kit+ group than in the c-kit- group, while hypoxia tended to increase cytokine expression in both groups. In addition, IGF-1 was significantly increased in the c-kit+ group, consistent with the relatively low expression of cleaved-caspase 3 revealed by western blot assay, and the relatively low count of apoptotic cells revealed by histochemical analysis. Administration of c-kit+cells into the MI heart improved the LVEF and increased neovascularization. These results indicate that c-kit+cells may be useful in cardiac stem cell therapy.
Early kit mortality and growth in farmed mink are affected by litter size rather than nest climate.
Schou, T M; Malmkvist, J
2017-09-01
We investigated the effects of nest box climate on early mink kit mortality and growth. We hypothesised that litters in warm nest boxes experience less hypothermia-induced mortality and higher growth rates during the 1st week of life. This study included data from 749, 1-year-old breeding dams with access to nesting materials. Kits were weighed on days 1 and 7, dead kits were collected daily from birth until day 7 after birth, and nest climate was measured continuously from days 1 to 6. We tested the influences of the following daily temperature (T) and humidity (H) parameters on the number of live-born kit deaths and kit growth: T mean, T min, T max, T var (fluctuation) and H mean. The nest microclimate experienced by the kits was buffered against the ambient climate, with higher temperatures and reduced climate fluctuation. Most (77.0%) live-born kit deaths in the 1st week occurred on days 0 and 1. Seven of 15 climate parameters on days 1 to 3 had significant effects on live-born kit mortality. However, conflicting effects among days, marginal effects and late effects indicated that climate was not the primary cause of kit mortality. Five of 30 climate parameters had significant effects on kit growth. Few and conflicting effects indicated that the climate effect on growth was negligible. One exception was that large nest temperature fluctuations on day 1 were associated with reduced deaths of live-born kit (P<0.001) and increased kit growth (P=0.003). Litter size affected kit vitality; larger total litter size at birth was associated with greater risks of kit death (P<0.001) and reduced growth (P<0.001). The number of living kits in litters had the opposite effect, as kits in large liveborn litters had a reduced risk of death (P<0.001) and those with large mean litter size on days 1 to 7 had increased growth (P=0.026). Nest box temperature had little effect on early kit survival and growth, which could be due to dams' additional maternal behaviour. Therefore, we cannot confirm that temperature is the primary reason for kit mortality, under the conditions of plenty straw access for maternal nest building. Instead, prenatal and/or parturient litter size is the primary factor influencing early kit vitality. The results indicate that the focus should be on litter size and dam welfare around the times of gestation and birth to increase early kit survival in farmed mink.
Use of a Novel Airway Kit and Simulation in Resident Training on Emergent Pediatric Airways.
Melzer, Jonathan M; Hamersley, Erin R S; Gallagher, Thomas Q
2017-06-01
Objective Development of a novel pediatric airway kit and implementation with simulation to improve resident response to emergencies with the goal of improving patient safety. Methods Prospective study with 9 otolaryngology residents (postgraduate years 1-5) from our tertiary care institution. Nine simulated pediatric emergency airway drills were carried out with the existing system and a novel portable airway kit. Response times and time to successful airway control were noted with both the extant airway system and the new handheld kit. Results were analyzed to ensure parametric data and compared with t tests. A Bonferroni adjustment indicated that an alpha of 0.025 was needed for significance. Results Use of the airway kit significantly reduced the mean time of resident arrival by 47% ( P = .013) and mean time of successful intubation by 50% ( P = .007). Survey data indicated 100% improved resident comfort with emergent airway scenarios with use of the kit. Discussion Times to response and meaningful intervention were significantly reduced with implementation of the handheld airway kit. Use of simulation training to implement the new kit improved residents' comfort and airway skills. This study describes an affordable novel mobile airway kit and demonstrates its ability to improve response times. Implications for Practice The low cost of this airway kit makes it a tenable option even for smaller hospitals. Simulation provides a safe and effective way to familiarize oneself with novel equipment, and, when possible, realistic emergent airway simulations should be used to improve provider performance.
Performance evaluation of a chemiluminescence microparticle immunoassay for CK-MB.
Lin, Zhi-Yuan; Fang, Yi-Zhen; Jin, Hong-Wei; Lin, Hua-Yue; Dai, Zhang; Luo, Qing; Li, Hong-Wei; Lin, Yan-Ling; Huang, Shui-Zhen; Gao, Lei; Xu, Fei-Hai; Zhang, Zhong-Ying
2018-03-31
To verify and evaluate the performance characteristics of a creatine kinase phosphokinase isoenzymes MB (CK-MB) assay kit, which produced by Xiamen Innodx Biotech Co. Ltd. Evaluation was carried out according to "Guidelines for principle of analysis performance evaluation of in vitro diagnostic reagent." The performance parameters included detection limit, linearity range, reportable range, recovery test, precision verification, interference test, cross-reactivity, matrix effect, and method comparison. The detection limit was 0.1 ng/mL. The assay had clinical linearity over range of 0.1 ng/mL-500 ng/mL. Reportable range was from 0.1 ng/mL to 1000 ng/mL. The average percent of recovery was 99.66%. The coefficient of variation (CV) for within-run and between-run of low CK-MB sample was 5.55% and 6.16%, respectively. As for high-level sample, it was 7.88% and 7.80%. In medical decision level, the relative deviation (Bias) of all interference tests was lower than 15%. When the sample had mild-hemolysis; hemoglobin ≤15 g/L; triglyceride ≤17 mmol/L; bilirubin ≤427.5 μmol/L; rheumatoid factor ≤206U/mL, there was no significant interference to be found. Moreover, assay kit had no cross-reaction with CK-MM and CK-BB. At last, total diagnostic accuracy of kit was 93.24%, when compared with refer kit. Overall the results of the verification study indicated the performance of kit is met the requirements of the clinical test. © 2018 Wiley Periodicals, Inc.
Nagarale, Girish; Ravindra, S; Thakur, Srinath; Setty, Swati
2010-10-01
C-reactive protein [CRP] levels increase to hundreds of mg/mL within hours following infection. Studies have shown that serum CRP levels were elevated in periodontal disease. However, in all the previous studies, CRP levels were measured by using high-sensitivity CRP assay kits with minimal detection limits of 0.1 to 3 mg/L, which was much below the normal value of 10 mg/L. These high-sensitivity CRP assays need a proper laboratory setup, and these methods cannot be used as a routine chair-side test in the dental office. The purpose of this study was to investigate the serum CRP levels in subjects with periodontal disease by using a rapid chair-side diagnostic test kit with a lower detection limit of 6 mg/L and to compare the CRP levels before and after periodontal therapy. A total of 45 systemically healthy subjects were selected for the study. Subjects were divided into three groups: group A: healthy controls, group B: gingivitis, group C: periodontitis. Serum levels of CRP were determined by using a latex slide agglutination method with commercially available kit with lower detection limit of 6 mg/L. CRP was negative in all the 15 subjects in groups A and B at baseline, 7th and 30th day. CRP was positive only in 2 subjects in Group C at baseline and 7th day. Estimation of serum CRP by using a rapid chair-side diagnostic test kit is not of any significance in subjects with periodontitis.
Nagarale, Girish; Ravindra, S.; Thakur, Srinath; Setty, Swati
2010-01-01
Background: C-reactive protein [CRP] levels increase to hundreds of mg/mL within hours following infection. Studies have shown that serum CRP levels were elevated in periodontal disease. However, in all the previous studies, CRP levels were measured by using high-sensitivity CRP assay kits with minimal detection limits of 0.1 to 3 mg/L, which was much below the normal value of 10 mg/L. These high-sensitivity CRP assays need a proper laboratory setup, and these methods cannot be used as a routine chair-side test in the dental office. Aim: The purpose of this study was to investigate the serum CRP levels in subjects with periodontal disease by using a rapid chair-side diagnostic test kit with a lower detection limit of 6 mg/L and to compare the CRP levels before and after periodontal therapy. Materials and Methods: A total of 45 systemically healthy subjects were selected for the study. Subjects were divided into three groups: group A: healthy controls, group B: gingivitis, group C: periodontitis. Serum levels of CRP were determined by using a latex slide agglutination method with commercially available kit with lower detection limit of 6 mg/L. Results: CRP was negative in all the 15 subjects in groups A and B at baseline, 7th and 30th day. CRP was positive only in 2 subjects in Group C at baseline and 7th day. Conclusion: Estimation of serum CRP by using a rapid chair-side diagnostic test kit is not of any significance in subjects with periodontitis. PMID:21731244
NASA Astrophysics Data System (ADS)
Barlow, P. M.; Filali-Meknassi, Y.; Sanford, W. E.; Winston, R. B.; Kuniansky, E.; Dawson, C.
2015-12-01
UNESCO's HOPE Initiative—the Hydro Free and (or) Open-source Platform of Experts—was launched in June 2013 as part of UNESCO's International Hydrological Programme. The Initiative arose in response to a recognized need to make free and (or) open-source water-resources software more widely accessible to Africa's water sector. A kit of software is being developed to provide African water authorities, teachers, university lecturers, and researchers with a set of programs that can be enhanced and (or) applied to the development of efficient and sustainable management strategies for Africa's water resources. The Initiative brings together experts from the many fields of water resources to identify software that might be included in the kit, to oversee an objective process for selecting software for the kit, and to engage in training and other modes of capacity building to enhance dissemination of the software. To date, teams of experts from the fields of wastewater treatment, groundwater hydrology, surface-water hydrology, and data management have been formed to identify relevant software from their respective fields. An initial version of the HOPE Software Kit was released in late August 2014 and consists of the STOAT model for wastewater treatment developed by the Water Research Center (United Kingdom) and the MODFLOW-2005 model for groundwater-flow simulation developed by the U.S. Geological Survey. The Kit is available on the UNESCO HOPE website (http://www.hope-initiative.net/).Training in the theory and use of MODFLOW-2005 is planned in southern Africa in conjunction with UNESCO's study of the Kalahari-Karoo/Stampriet Transboundary Aquifer, which extends over an area that includes parts of Botswana, Namibia, and South Africa, and in support of the European Commission's Horizon 2020 FREEWAT project (FREE and open source software tools for WATer resource management; see the UNESCO HOPE website).
Uadiale, Kennedy; Bestman, Agatha; Kamau, Charity; Caugant, Dominique A.; Greig, Jane
2016-01-01
Background Neisseria meningitidis serogroup C (NmC) has caused outbreaks in Nigeria of increasing size in three consecutive years since 2013. Rapid diagnostic tests (RDTs) for meningitis can facilitate quick identification of the causative pathogen; Pastorex can detect N. meningitidis serogroups A, C (NmC), Y/W135, N. meningitidis serogroup B/Escherichia coli K1, Haemophilus influenzae type b (Hib), Streptococcus pneumoniae, and group B Streptococcus. There is no published field evaluation of Pastorex in the identification of NmC. We report our experience with Pastorex in detecting NmC in field conditions. Methods During sequential outbreaks of NmC in Nigeria in 2013, 2014 and 2015, cerebrospinal fluid (CSF) was collected from suspected cases of meningitis that met the case definition. Pastorex latex agglutination rapid test was done in the field and trans-isolate media were inoculated with CSF for culture and/or PCR, which was used as the reference standard for 63 paired samples. Results The sensitivity of Pastorex for NmC was 80.0% (95% CI 65.4–90.4%) and the specificity was 94.4% (95% CI 72.7–99.9%). The positive likelihood ratio (LR) was 14.4 (95% CI 2.1–97.3) and negative LR was 0.2 (95% CI 0.1–0.4). The positive and negative predictive values (PPV and NPV) were 97.3% (95% CI 85.8–99.9) and 65.4% (95% CI 44.3–82.8), respectively, with a prevalence estimate of 71.4% (95% CI 58.6–82.1). Conclusion Pastorex showed good performance in detecting NmC under field conditions. Prepositioning Pastorex at peripheral health facilities during non-epidemic periods is constrained by a short shelf-life of 1 month after the kit is opened. There is need for development of RDTs that are cheaper and with less challenging requirements for storage and usage. PMID:27496511
Witt, Sebastian; Neumann, Jan; Zierdt, Holger; Gébel, Gabriella; Röscheisen, Christiane
2012-09-01
Automated systems have been increasingly utilized for DNA extraction by many forensic laboratories to handle growing numbers of forensic casework samples while minimizing the risk of human errors and assuring high reproducibility. The step towards automation however is not easy: The automated extraction method has to be very versatile to reliably prepare high yields of pure genomic DNA from a broad variety of sample types on different carrier materials. To prevent possible cross-contamination of samples or the loss of DNA, the components of the kit have to be designed in a way that allows for the automated handling of the samples with no manual intervention necessary. DNA extraction using paramagnetic particles coated with a DNA-binding surface is predestined for an automated approach. For this study, we tested different DNA extraction kits using DNA-binding paramagnetic particles with regard to DNA yield and handling by a Freedom EVO(®)150 extraction robot (Tecan) equipped with a Te-MagS magnetic separator. Among others, the extraction kits tested were the ChargeSwitch(®)Forensic DNA Purification Kit (Invitrogen), the PrepFiler™Automated Forensic DNA Extraction Kit (Applied Biosystems) and NucleoMag™96 Trace (Macherey-Nagel). After an extensive test phase, we established a novel magnetic bead extraction method based upon the NucleoMag™ extraction kit (Macherey-Nagel). The new method is readily automatable and produces high yields of DNA from different sample types (blood, saliva, sperm, contact stains) on various substrates (filter paper, swabs, cigarette butts) with no evidence of a loss of magnetic beads or sample cross-contamination. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Immunohistochemical study of C-kit expression in subtypes of renal cell carcinoma.
Norouzinia, Farahnaz; Abbasi, Fariba; Dindarian, Sina; Mohammadi, Sedra; Meisami, Farid; Bagheri, Mahdi; Mohammadi, Hozan
2018-01-01
Renal cell carcinomas (RCCs) include about 2% of adult neoplasms and 90-95% of all renal tumors. Mostly, it is possible to distinguish RCC subtypes using hematoxylin-eosin staining. However, overlapping morphologic features cause some difficulties in making a precise diagnosis. In order to render an accurate diagnosis, additional methods such as immunohistochemical staining for c-kit have been recommended. In this study, we aimed to investigate c-kit gene expression in various subtypes of RCC. We reviewed 65 diagnosed RCC cases. Formalin- fixed, paraffin- embedded specimens were available for the cases. The expression of c-kit was evaluated using immunohistochemistry. The correlation between c-kit expression and clinicopathological parameters including patients' age and gender in addition to grade, stage, and size of the tumor were investigated. Six cases of 39 clear cell types (15.4%), 8 of 13 papillary types (61.5%), 11 of 12 chromophobe types (91.7%), and no sarcomatoid type were positive for c-kit expression. Based on chi-square test results, there was a significant relationship between RCC subtypes and c-kit expression (p=0.001). There was no significant correlation between age, sex, grade, stage, and size of the tumor and c-kit expression. The expression of c-kit in RCC may have diagnostic significance in subtypes of RCC especially papillary and chromophobe subtypes of RCC.
Zhong, Fei; Tang, Weiming; Cheng, Weibin; Lin, Peng; Wu, Qiongmiao; Cai, Yanshan; Tang, Songyuan; Fan, Lirui; Zhao, Yuteng; Chen, Xi; Mao, Jessica; Meng, Gang; Tucker, Joseph D.; Xu, Huifang
2017-01-01
Background HIV self-testing (HIVST) offers an opportunity to increase HIV testing among people not reached by facility-based services. However, the promotion of HIVST is limited due to insufficient community engagement. We built a Social Entrepreneurship Model (SET) to promote HIVST linkage to care among Chinese MSM in Guangzhou. Method SET model includes a few key steps: Each participant first completed an online survey, and paid a $23 USD (refundable) deposit to get a HIVST kit and a syphilis self-testing (SST) kit. After the testing, the results were sent to the platform by the participants and interpreted by CDC staff. Meanwhile, the deposit was returned to each participant. Finally, the CBO contacted the participants to provide counseling services, confirmation testing and linkage to care. Result During April–June of 2015, a total of 198 MSM completed a preliminary survey and purchased self-testing kits. Among them, the majority were aged under 34 (84.4%) and met partners online (93.1%). In addition, 68.9% of participants ever tested for HIV, and 19.5% had ever performed HIVST. Overall, feedback was received from 192 (97.0%) participants. Among these, 14 people did not use kits, and the HIV and syphilis prevalence among these users were of 4.5% (8/178) and 3.7% (6/178), respectively. All of the screened HIV-positive cases sought further confirmation testing and were linked to care. Conclusion Using an online SET model to promote HIV and syphilis among Chinese MSM is acceptable and feasible, and this model adds a new testing platform to the current testing service system. PMID:27601301
Arsenic exposure in drinking water: an unrecognized health threat in Peru.
George, Christine Marie; Sima, Laura; Arias, M Helena Jahuira; Mihalic, Jana; Cabrera, Lilia Z; Danz, David; Checkley, William; Gilman, Robert H
2014-08-01
To assess the extent of arsenic contamination of groundwater and surface water in Peru and, to evaluate the accuracy of the Arsenic Econo-Quick(™) (EQ) kit for measuring water arsenic concentrations in the field. Water samples were collected from 151 water sources in 12 districts of Peru, and arsenic concentrations were measured in the laboratory using inductively-coupled plasma mass spectrometry. The EQ field kit was validated by comparing a subset of 139 water samples analysed by laboratory measurements and the EQ kit. In 86% (96/111) of the groundwater samples, arsenic exceeded the 10 µg/l arsenic concentration guideline given by the World Health Organization (WHO) for drinking water. In 56% (62/111) of the samples, it exceeded the Bangladeshi threshold of 50 µg/l; the mean concentration being 54.5 µg/l (range: 0.1-93.1). In the Juliaca and Caracoto districts, in 96% (27/28) of groundwater samples arsenic was above the WHO guideline; and in water samples collected from the section of the Rímac river running through Lima, all had arsenic concentrations exceeding the WHO limit. When validated against laboratory values, the EQ kit correctly identified arsenic contamination relative to the guideline in 95% (106/111) of groundwater and in 68% (19/28) of surface water samples. In several districts of Peru, drinking water shows widespread arsenic contamination, exceeding the WHO arsenic guideline. This poses a public health threat requiring further investigation and action. For groundwater samples, the EQ kit performed well relative to the WHO arsenic limit and therefore could provide a vital tool for water arsenic surveillance.
Habitat evaluation using GIS a case study applied to the San Joaquin Kit Fox
Gerrard, R.; Stine, P.; Church, R.; Gilpin, M.
2001-01-01
Concern over the fate of plant and animal species throughout the world has accelerated over recent decades. Habitat loss is considered the main culprit in reducing many species' abundance and range, leading to numerous efforts to plan and manage habitat preservation. Our work uses Geographic Information Systems (GIS) data and modeling to define a spatially explicit analysis of habitat value, using the San Joaquin Kit Fox (Vulpes macrotis mutica) of California (USA) as an example. Over the last 30 years, many field studies and surveys have enhanced our knowledge of the life history, behavior, and needs of the kit fox, which has been proposed as an umbrella or indicator species for grassland habitat in the San Joaquin Valley of California. There has yet been no attempt to convert much of this field knowledge into a model of spatial habitat value useful for planning purposes. This is a significant omission given the importance and visibility of the imperiled kit fox and increasing trends toward spatially explicit modeling and planning. In this paper we apply data from northern California to derive a small-cell GIS raster of habitat value for the kit fox that incorporates both intrinsic habitat quality and neighborhood context, as well the effects of barriers such as roads. Such a product is a useful basis for assessing the presence and amounts of good (and poor) quality habitat and for eventually constructing GIS representations of viable animal territories that could be included in future reserves. ?? 2001 Elsevier Science B.V.
Duration of antibody response following vaccination against feline immunodeficiency virus.
Westman, Mark E; Malik, Richard; Hall, Evelyn; Harris, Matthew; Hosie, Margaret J; Norris, Jacqueline M
2017-10-01
Objectives Recently, two point-of-care (PoC) feline immunodeficiency virus (FIV) antibody test kits (Witness and Anigen Rapid) were reported as being able to differentiate FIV-vaccinated from FIV-infected cats at a single time point, irrespective of the gap between testing and last vaccination (0-7 years). The aim of the current study was to investigate systematically anti-FIV antibody production over time in response to the recommended primary FIV vaccination series. Methods First, residual plasma from the original study was tested using a laboratory-based ELISA to determine whether negative results with PoC testing were due to reduced as opposed to absent antibodies to gp40. Second, a prospective study was performed using immunologically naive client-owned kittens and cats given a primary FIV vaccination series using a commercially available inactivated whole cell/inactivated whole virus vaccine (Fel-O-Vax FIV, three subcutaneous injections at 4 week intervals) and tested systematically (up to 11 times) over 6 months, using four commercially available PoC FIV antibody kits (SNAP FIV/FeLV Combo [detects antibodies to p15/p24], Witness FeLV/FIV [gp40], Anigen Rapid FIV/FeLV [p24/gp40] and VetScan FeLV/FIV Rapid [p24]). Results The laboratory-based ELISA showed cats from the original study vaccinated within the previous 0-15 months had detectable levels of antibodies to gp40, despite testing negative with two kits that use gp40 as a capture antigen (Witness and Anigen Rapid kits). The prospective study showed that antibody testing with SNAP Combo and VetScan Rapid was positive in all cats 2 weeks after the second primary FIV vaccination, and remained positive for the duration of the study (12/12 and 10/12 cats positive, respectively). Antibody testing with Witness and Anigen Rapid was also positive in a high proportion of cats 2 weeks after the second primary FIV vaccination (8/12 and 7/12, respectively), but antibody levels declined below the level of detection in most cats (10/12) by 1 month after the third (final) primary FIV vaccination. All cats tested negative using Witness and Anigen Rapid 6 months after the third primary FIV vaccination. Conclusions and relevance This study has shown that a primary course of FIV vaccination does not interfere with FIV antibody testing in cats using Witness and Anigen Rapid, provided primary vaccination has not occurred within the previous 6 months. Consequently, Witness and Anigen Rapid antibody test kits can be used reliably to determine FIV infection status at the time of annual booster FIV vaccination to help detect 'vaccine breakthroughs' and in cats that have not received a primary course of FIV vaccination within the preceding 6 months. The duration of antibody response following annual booster FIV vaccination and the resulting effect on antibody testing using PoC kits needs to be determined by further research. The mechanism(s) for the variation in FIV antibody test kit performance remains unclear.
Field soil aggregate stability kit for soil quality and rangeland health evaluations
Herrick, J.E.; Whitford, W.G.; de Soyza, A. G.; Van Zee, J. W.; Havstad, K.M.; Seybold, C.A.; Walton, M.
2001-01-01
Soil aggregate stability is widely recognized as a key indicator of soil quality and rangeland health. However, few standard methods exist for quantifying soil stability in the field. A stability kit is described which can be inexpensively and easily assembled with minimal tools. It permits up to 18 samples to be evaluated in less than 10 min and eliminates the need for transportation, minimizing damage to soil structure. The kit consists of two 21??10.5??3.5 cm plastic boxes divided into eighteen 3.5??3.5 cm sections, eighteen 2.5-cm diameter sieves with 1.5-mm distance openings and a small spatula used for soil sampling. Soil samples are rated on a scale from one to six based on a combination of ocular observations of slaking during the first 5 min following immersion in distilled water, and the percent remaining on a 1.5-mm sieve after five dipping cycles at the end of the 5-min period. A laboratory comparison yielded a correlation between the stability class and percent aggregate stability based on oven dry weight remaining after treatment using a mechanical sieve. We have applied the method in a wide variety of agricultural and natural ecosystems throughout western North America, including northern Mexico, and have found that it is highly sensitive to differences in management and plant community composition. Although the field kit cannot replace the careful laboratory-based measurements of soil aggregate stability, it can clearly provide valuable information when these more intensive procedures are not possible.
Wood, Martyn; Ellks, Rachael; Grobicki, Moira
2015-05-01
Men who have sex with men (MSM) have higher rates of poor sexual health. The National Institute for Health and Care Excellence has produced guidance on increasing the uptake of HIV testing to reduce undiagnosed infection in MSM. We report the results of a pilot outreach sexually transmitted infection service using nurse-delivered screening and self-sampled postal testing at a sex on premises venue with comparison made against a sexual health clinic service. Thirty men were included in each group. Users of the nurse-delivered and postal services were older (nurse service median age 57.5 years vs. postal kit service 47 years vs. clinic 35.5 years, p ≤ 0.001). Outreach groups were less likely to have undertaken sexually transmitted infection testing previously than the clinic group (53.3% and 60% vs. 93.3%, p ≤ 0.001). Chlamydia trachomatis and Neisseria gonorrhoeae testing uptake was comparable across groups (nurse outreach 86.6%, 'do it yourself' postal kit 100% vs. clinic 100%, p = 0.032), but uptake for blood tests was lower in the postal kit group (nurse outreach 83.3%, postal kit 53.3% vs. clinic 100%, p ≤ 0.001). No significant difference in active sexually transmitted infection positivity across the groups was observed. This combination outreach screening approach is effective in targeting MSM who use sex on premises venues. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Commercial test kits for detection of Lyme borreliosis: a meta-analysis of test accuracy
Cook, Michael J; Puri, Basant K
2016-01-01
The clinical diagnosis of Lyme borreliosis can be supported by various test methodologies; test kits are available from many manufacturers. Literature searches were carried out to identify studies that reported characteristics of the test kits. Of 50 searched studies, 18 were included where the tests were commercially available and samples were proven to be positive using serology testing, evidence of an erythema migrans rash, and/or culture. Additional requirements were a test specificity of ≥85% and publication in the last 20 years. The weighted mean sensitivity for all tests and for all samples was 59.5%. Individual study means varied from 30.6% to 86.2%. Sensitivity for each test technology varied from 62.4% for Western blot kits, and 62.3% for enzyme-linked immunosorbent assay tests, to 53.9% for synthetic C6 peptide ELISA tests and 53.7% when the two-tier methodology was used. Test sensitivity increased as dissemination of the pathogen affected different organs; however, the absence of data on the time from infection to serological testing and the lack of standard definitions for “early” and “late” disease prevented analysis of test sensitivity versus time of infection. The lack of standardization of the definitions of disease stage and the possibility of retrospective selection bias prevented clear evaluation of test sensitivity by “stage”. The sensitivity for samples classified as acute disease was 35.4%, with a corresponding sensitivity of 64.5% for samples from patients defined as convalescent. Regression analysis demonstrated an improvement of 4% in test sensitivity over the 20-year study period. The studies did not provide data to indicate the sensitivity of tests used in a clinical setting since the effect of recent use of antibiotics or steroids or other factors affecting antibody response was not factored in. The tests were developed for only specific Borrelia species; sensitivities for other species could not be calculated. PMID:27920571
NASA Technical Reports Server (NTRS)
Greene, Benjamin; Buchanan, Vanessa D.; Baker, David L.
2006-01-01
Dimethylamine and nitrite, which are non-combustion reaction products of unsymmetrical dimethylhydrazine (UDMH) and nitrogen tetroxide (NTO) propellants, can contaminate spacesuits during extra-vehicular activity (EVA) operations. They can react with water in the International Space Station (ISS) airlock to form N-nitrosodimethylamine (NDMA), a carcinogen. Detection methods for assessing nitrite and dimethylamine contamination were investigated. The methods are based on color-forming reactions in which intensity of color is proportional to concentration. A concept color detection kit using a commercially available presumptive field test for methamphetamine coupled with nitrite test strips was developed and used to detect dimethylamine and nitrite. Contamination mitigation strategies were also developed.
Kim, Saorin; Nhem, Sina; Dourng, Dany; Ménard, Didier
2015-03-14
Malaria rapid diagnostic tests (RDTs) are generally considered as point-of-care tests. However, most of the studies assessing the performance of malaria RDTs are conducted by research teams that are not representative of the classical end-users, who are typically unskilled in traditional laboratory techniques for diagnosing malaria. To evaluate the performance of a malaria RDT by end-users in a malaria-endemic area, a study protocol was designed and the VIKIA Malaria Ag Pf/Pan test, previously evaluated in 2013, was re-evaluated by representative end-users. Twenty end-users with four different profiles in seven communes in Kampot Province (Cambodia) were selected. A set of 20 calibrated aliquots, including negative samples, low positive samples (200 parasites/μL of Plasmodium falciparum and Plasmodium vivax) and high positive samples (2,000 parasites/μL of P. falciparum and P. vivax) was used. Testing was performed directly by the end-users without any practical training on the VIKIA Malaria Ag Pf/Pan kit. All results obtained by the end-users were consistent with the expected results, except for the low positive (200 parasites/μL) P. vivax aliquot (35% of concordant results). No significant difference was observed between the different end-users. End-user interviews evaluating ease-of-use and ease-of-reading of the VIKIA Malaria Ag Pf/Pan kit recorded 159 positive answers and only one negative answer. Out of 20 end-users, only one considered the test was not easy to perform with the support of the quick guide. The data presented in this study clearly demonstrate that the performance of the VIKIA Malaria Ag Pf/Pan test when performed by traditional end-users in field conditions is similar to that obtained by a research team and that this RDT can be considered as a point-of-care tool/assay. Furthermore, the protocol designed for this study could be used systematically in parallel to conventional evaluation studies to determine the performance of malaria RDTs in field conditions.
Cramer, Josh; Quintero, Miguel; Rhinehart, Alex; Rutherford, Caitlin; Nasypany, Alan; May, James; Baker, Russell T
2017-02-01
Physical performance measures (PPMs) such as The Star Excursion Balance Test (SEBT) and the Y-Balance Test (YBT) are functional movement tests used to assess participants' dynamic balance, which can be a vital component in physical exams to identify predisposing factors for risk of injury. The YBT is a functional assessment tool for the upper and lower body. It evolved from the SEBT, which has been previously used in research as a lower body functional assessment. It is comprised of fewer movement directions, which help limit fatigue. The YBT kit is a commercialized tool, which may pose barriers for clinicians with limited budgets and/or strict approval process for purchasing capital items in their clinics, especially healthcare providers in the secondary school setting. The cost may also pose a barrier for researchers with limited budgets. A less expensive, easy to make kit, may provide clinicians an opportunity to integrate functional testing into their evaluation or research. The purpose of this pilot study was to describe a cost efficient method to gather participant's upper quarter YBT (UQYBT) measurements and examine the inter- and intra-rater score agreement between this method and the commercial YBT measurements. A convenience sample of 20 physically active participants volunteered to participate in a comparison study of the of Upper Quarter Y-Balance Test (UQYBT) using the commercialized kit and the Modified Upper Quarter Y-Balance Test kit (mUQYBT) made with three cloth tape measures, athletic tape, a goniometer and three 2x4x8 wood blocks. A Pearson Product Moment correlation and Bland-Altman analyses were used to examine the relationship between intra-rater scores comparing the UQYBT and mUQYBT. Inter-rater scores were analyzed using intraclass correlation coefficients (ICC) (2,1) and Bland-Altman analyses. All Pearson Product Moment r-values for intra-rater scores were greater than .96 and statistically significant at p<0.05. Coefficients of determination suggest that the mUQYBT scores account for approximately 92% of the UQYBT composite score when analyzing intra-rater comparisons. Bland-Altman plots suggest moderate agreement between the two tests with a potential bias towards higher composite scores in the mUQYBT. Inter-rater ICC scores were all greater than .98, while Bland-Altman plot analyses suggest moderate agreement between the raters. The mUQYBT produced similar results in both inter- and intra-rater measurements when compared to the commercialized YBT kit and offers a cost-effective alternative for assessing upper quarter PPMs for clinicians with limited budgets. 2b.
Al-Maqtari, Tareq; Cao, Pengxiao; Keith, Matthew C. L.; Wysoczynski, Marcin; Zhao, John; Moore IV, Joseph B.; Bolli, Roberto
2015-01-01
A recent phase I clinical trial (SCIPIO) has shown that autologous c-kit+ cardiac progenitor cells (CPCs) improve cardiac function and quality of life when transplanted into patients with ischemic heart disease. Although c-kit is widely used as a marker of resident CPCs, its role in the regulation of the cellular characteristics of CPCs remains unknown. We hypothesized that c-kit plays a role in the survival, growth, and migration of CPCs. To test this hypothesis, human CPCs were grown under stress conditions in the presence or absence of SCF, and the effects of SCF-mediated activation of c-kit on CPC survival/growth and migration were measured. SCF treatment led to a significant increase in cell survival and a reduction in cell death under serum depletion conditions. In addition, SCF significantly promoted CPC migration in vitro. Furthermore, the pro-survival and pro-migratory effects of SCF were augmented by c-kit overexpression and abrogated by c-kit inhibition with imatinib. Mechanistically, c-kit activation in CPCs led to activation of the PI3K and the MAPK pathways. With the use of specific inhibitors, we confirmed that the SCF/c-kit-dependent survival and chemotaxis of CPCs are dependent on both pathways. Taken together, our findings suggest that c-kit promotes the survival/growth and migration of human CPCs cultured ex vivo via the activation of PI3K and MAPK pathways. These results imply that the efficiency of CPC homing to the injury site as well as their survival after transplantation may be improved by modulating the activity of c-kit. PMID:26474484
Digital PCR: A Sensitive and Precise Method for KIT D816V Quantification in Mastocytosis.
Greiner, Georg; Gurbisz, Michael; Ratzinger, Franz; Witzeneder, Nadine; Simonitsch-Klupp, Ingrid; Mitterbauer-Hohendanner, Gerlinde; Mayerhofer, Matthias; Müllauer, Leonhard; Sperr, Wolfgang R; Valent, Peter; Hoermann, Gregor
2018-03-01
The analytically sensitive detection of KIT D816V in blood and bone marrow is important for diagnosing systemic mastocytosis (SM). Additionally, precise quantification of the KIT D816V variant allele fraction (VAF) is relevant clinically because it helps to predict multilineage involvement and prognosis in cases of advanced SM. Digital PCR (dPCR) is a promising new method for sensitive detection and accurate quantification of somatic mutations. We performed a validation study of dPCR for KIT D816V on 302 peripheral blood and bone marrow samples from 156 patients with mastocytosis for comparison with melting curve analysis after peptide nucleic acid-mediated PCR clamping (clamp-PCR) and allele-specific quantitative real-time PCR (qPCR). dPCR showed a limit of detection of 0.01% VAF with a mean CV of 8.5% and identified the mutation in 90% of patients compared with 70% for clamp-PCR ( P < 0.001). Moreover, dPCR for KIT D816V was highly concordant with qPCR without systematic deviation of results, and confirmed the clinical value of KIT D816V VAF measurements. Thus, patients with advanced SM showed a significantly higher KIT D816V VAF (median, 2.43%) compared with patients with indolent SM (median, 0.14%; P < 0.001). Moreover, dPCR confirmed the prognostic significance of a high KIT D816V VAF regarding survival ( P < 0.001). dPCR for KIT D816V provides a high degree of precision and sensitivity combined with the potential for interlaboratory standardization, which is crucial for the implementation of KIT D816V allele burden measurement. Thus, dPCR is suitable as a new method for KIT D816V testing in patients with mastocytosis. © 2017 American Association for Clinical Chemistry.
Zhao, Meng-Chuan; Li, Gui-Xia; Zhang, Dan; Zhou, Hang-Yu; Wang, Hao; Yang, Shuo; Wang, Le; Feng, Zhi-Shan; Ma, Xue-Jun
2017-06-01
Respiratory Pathogen 13 Detection Kit (13× kit) is able to simultaneously detect 11 respiratory viruses, Mycoplasma pneumoniae (MP) and Chlamydia in a single reaction. Using 572 Nasopharyngeal aspirates collected from hospitalized children, the clinical performance of 13× kit for detecting 11 respiratory viruses was evaluated in comparison with a routinely used 2-tube multiplex reverse transcription PCR assay (2-tube assay) at provincial Centers for Disease Control and Prevention in China. The clinical performance of 13× kit for detecting MP and Chlamydia was evaluated by commercial real-time quantitative PCR (qPCR) kits or sequencing. For tested viruses, the assay concordance was 95.98% and the kappa coefficient was 0.89. All the MP and Chlamydia positive samples detected by 13× kit were confirmed as true positives. The utilization of the 13× kit in clinical settings will be helpful for doctors to assess clinical outcome according to virus type or multiple infections, and to limit the use of antibiotics. Copyright © 2017 Elsevier Inc. All rights reserved.
1989-04-28
camera, and document test events and recorder procedures Thermometer +20C Psychrometer +5% 4 April 1989 TOP 8-2-555 Rough handling test and As specifie...not covered in AMC Regulation 385-131 will be performed iAW p oposals made by the Chemical Laboratory Division and approved by the Safety ¶ffice. 4.3...the packaged detector kit to higher and lower temperatures than it is expected to experience in actual packaged storage. Coordination should be made
Shin, Kyeong Seob; Song, Hyung Geun; Kim, Haejung; Yoon, Sangsun; Hong, Seung Bok; Koo, Sun Hoe; Kim, Jimyung; Kim, Jongwan; Roh, Kyoung Ho
2010-07-01
Using an EZ-Step MRSA rapid kit, a novel screening test for methicillin-resistant Staphylococcus aureus (MRSA) that detects penicillin-binding protein 2a, 34 of 36 MRSA-positive clinical blood culture samples were positive on direct testing (sensitivity, 94.4%), whereas 21 of 21 methicillin-susceptible S. aureus-positive samples were negative (specificity, 100%).
Diagnostic performance of the "MESACUP anti-Skin profile TEST".
Horváth, Orsolya N; Varga, Rita; Kaneda, Makoto; Schmidt, Enno; Ruzicka, Thomas; Sárdy, Miklós
2016-01-01
The "MESACUP anti-Skin profile TEST" is a new, commercially available ELISA kit to detect circulating IgG autoantibodies against desmoglein 1, desmoglein 3, BP180, BP230, and type VII collagen, both simultaneously and more rapidly than previous assays. The aim of this study was to evaluate the diagnostic accuracy of this kit for the diagnosis of pemphigus foliaceus, pemphigus vulgaris, bullous pemphigoid and epidermolysis bullosa acquisita. Dual-centre retrospective study in which 138 patients with autoimmune blistering diseases were compared to 40 controls Using the MESACUP anti-Skin profile TEST, both sensitivities and specificities for desmoglein 1, desmoglein 3, BP180, BP230, and type VII collagen autoantibodies were similar to those obtained using previous, specific ELISA systems and 88% of the results were concordant without any significant difference. The MESACUP anti-Skin profile TEST had a similar performance to previously produced ELISA systems. The novel kit can be used for rapid diagnosis of most common autoimmune blistering diseases and is especially suitable for identifying overlapping disorders.
Stage-specific expression of DDX4 and c-kit at different developmental stages of the porcine testis.
Lee, Ran; Lee, Won-Young; Park, Hyun-Jung; Ha, Woo-Tae; Woo, Jae-Seok; Chung, Hak-Jae; Lee, Ji-Heon; Hong, Kwonho; Song, Hyuk
2018-03-01
Spermatogenesis begins with spermatogonial stem cells (SSCs), which are located in the basement membrane of the adult testes. Previous studies have described specific biomarkers for undifferentiated porcine spermatogonia or SSCs; however, these markers are not sufficient to understand spermatogenesis at different developmental stages. The objective of this study was characterize the expression of DEAD-Box polypeptide 4 (DDX4, also known as VASA) and tyrosine-protein kinase kit (c-kit), as potential markers of male germ cells in the porcine testis. In porcine testis tissue at prepubertal stages (5, 30, and 60 days), DDX4 and c-kit protein expression was detected in the most undifferentiated spermatogonia, which also express protein gene product 9.5 (PGP9.5). However, in porcine testis tissues from pubertal and postpubertal stages (90, 120, and 150 days), DDX4 and c-kit were not detected in PGP9.5-positive undifferentiated spermatogonia. The DDX4 expression pattern was similar to that of c-kit in the porcine testis. In adult porcine testes, DDX4-expressing cells were located on the lumenal side, compared to synaptonemal complex protein 3-positive primary spermatocytes, but DDX-4 was not co-expressed with acrosin, a known acrosome marker. In addition, DDX4 was detected in PGP9.5-expressing porcine SSCs in culture. Based on our results, we suggest that DDX4 and c-kit are putative markers of undifferentiated spermatogonia in the prepubertal porcine testis. While in the postpubertal porcine testis, they are markers of differentiated spermatocytes. These findings may facilitate future studies of porcine spermatogenesis. Copyright © 2018 Elsevier B.V. All rights reserved.
Korde, Aruna; Mallia, Madhava; Shinto, Ajit; Sarma, H D; Samuel, Grace; Banerjee, Sharmila
2014-11-01
(99m)Tc-HYNIC-TOC is a cost-effective and logistically viable agent for scintigraphy of neuroendocrine tumors overexpressing somatostatin receptors as compared with [(111)In-DTPA-D-Phe(1)] Octreotide (Octreoscan(®)). Several studies have been reported, wherein the efficacy of this agent is demonstrated. In the present article, the authors report the preparation of a single-vial HYNIC-TOC kit suitable for the preparation of 4-5 patient doses (15 mCi/patient) of (99m)Tc-HYNIC-TOC. The kits were tested for sterility and bacterial endotoxins to assure safety of the product. A significant modification in this kit is the inclusion of buffer in the kit itself, unlike in commercially available kits where the buffer solution has to be added during preparation. (99m)Tc-HYNIC-TOC was prepared by adding 20-80 mCi (740-2960 MBq) of freshly eluted Na(99m)TcO4 in 1-3 mL of sterile saline directly into the kit vial and heating the vial in a water bath at 100°C for 20 minutes. The labeling yield and radiochemical purity of (99m)Tc-HYNIC-TOC, prepared using the lyophilized cold kit, were consistently >90%. The kits were evaluated over a period of 9 months and found to be stable when stored at -20°C. Limited clinical studies performed with the (99m)Tc-HYNIC-TOC, formulated using the kit, showed adequate sensitivity and specificity for the detection of gasteroenteropancreatic neuroendocrine tumors.
Piera, Kim A; Aziz, Ammar; William, Timothy; Bell, David; González, Iveth J; Barber, Bridget E; Anstey, Nicholas M; Grigg, Matthew J
2017-01-13
Plasmodium knowlesi is the most common cause of malaria in Malaysia. However, microscopic diagnosis is inaccurate and rapid diagnostic tests (RDTs) are insufficiently sensitive. PCR is sensitive and specific but not feasible at a district level. Loop-mediated isothermal amplification (LAMP) shows potential with only basic requirements. A commercially available LAMP assay, the Eiken Loopamp™ MALARIA Pan Detection kit, is sensitive for Plasmodium falciparum and Plasmodium vivax, but has not previously been evaluated for P. knowlesi. This study aims to determine the sensitivity of this LAMP assay for detecting P. knowlesi infection. Study participants included 73 uncomplicated malaria patients with PCR species confirmation: 50 P. knowlesi, 20 P. falciparum and 3 P. vivax. Nineteen malaria-negative, non-endemic area controls were also included. The sensitivity of the Eiken Loopamp™ MALARIA Pan Detection kit (Pan LAMP) for detecting each Plasmodium species was evaluated. Sensitivity and specificity of the Eiken Loopamp™ MALARIA Pf Detection kit (Pf LAMP) for P. falciparum were also determined. The limit of detection for each LAMP assay was evaluated, with results compared to PCR. All P. knowlesi patients were also tested by CareStart™ (Pf/VOM) and OptiMAL-IT™ (Pan/Pf) RDTs. The sensitivity of the Pan LAMP assay was 100% for P. knowlesi (95% CI 92.9-100), P. falciparum (95% CI 83.2-100), and P. vivax (95% CI 29.2-100). The Pf LAMP was 100% sensitive and specific for P. falciparum detection, with all P. knowlesi samples having a negative reaction. LAMP sensitivity was superior to both RDTs, with only 10 and 28% of P. knowlesi samples testing positive to CareStart™ and OptiMAL-IT™, respectively. Limit of detection using the Pan LAMP for both P. knowlesi and P. vivax was 2 parasites/μL, comparable to PCR. For P. falciparum both the Pan LAMP and Pf LAMP demonstrated a limit of detection of 20 parasites/μL. The Eiken Loopamp™ MALARIA Pan Detection kit is sensitive for detection of P. knowlesi in low parasitaemia clinical infections, as well as P. falciparum and P. vivax. However, a P. knowlesi-specific field assay in a simpler format would assist correct species identification and initiation of optimal treatment for all malaria patients.
Kim, Seoung-Cheol; Jeon, Bo-Young; Kim, Jin-Sook; Choi, In Hwan; Kim, Jiro; Woo, Jeongim; Kim, Soojin; Lee, Hyeong Woo; Sezim, Monoldorova; Cho, Sang-Nae
2016-10-01
Tuberculosis (TB) is a major health problem, and accurate and rapid diagnosis of multidrug-resistant (MDR) and extended drug-resistant (XDR) TB is important for appropriate treatment. In this study, performances of solid and liquid culture methods were compared with respect to MDR- and XDR-TB isolate recovery and drug susceptibility testing. Sputum specimens from 304 patients were stained with Ziehl-Neelsen method. Mycobacterium tuberculosis (Mtb) isolates were tested for recovery on Löwenstein-Jensen (LJ) medium and the BacT Alert 3D system. For drug susceptibility testing of Mtb, isolates were evaluated on M-KIT plates and the BacT Alert 3D system. The recovery rates were 94.9% (206/217) and 98.2% (213/217) for LJ medium and the BacT Alert 3D system, respectively (kappa coefficient, 0.884). The rate of drug resistance was 13.4% for at least one or more drugs, 6.0% for MDR-TB and 2.3% for XDR-TB. M-KIT plate and BacT 3D Alert 3D system were comparable in drug susceptibility testing for isoniazid (97.7%; kappa coefficient, 0.905) and rifampin (98.6%; kappa coefficient, 0.907). Antibiotic resistance was observed using M-KIT plates for 24 of the total 29 Mtb isolates (82.8%). The liquid culture system showed greater reduction in the culture period, as compared with LJ medium; however, drug susceptibility testing using M-KIT plates was advantageous for simultaneous testing against multiple drug targets.
Zheng, Si-Li; Li, Zhi-Yong; Zhang, Zheng; Wang, Dong-Sheng; Xu, Jian; Miao, Chao-Yu
2018-04-01
Metrnl is a newly discovered secreted protein with neurotrophic activity and metabolic effect, while in earlier studies its circulating level in human was not explored. We evaluated two commercial enzyme-linked immunosorbent assay kits (DY7867-05, R&D Systems and SK00478-02, Aviscera Bioscience) for the detection of human circulating Metrnl. The DY7867-05 kit showed superiority over the SK00478-02 kit since it generated better curve fitting degree, smaller variation among tests, higher inter-assay reproducibility and better specificity, and could effectively detect human Metrnl in six types of blood samples. Subsequent analysis was performed using the DY7867-05 kit. Sample storage conditions were investigated. No gender difference in circulating Metrnl levels was found, while people with newly diagnosed type 2 diabetes mellitus (T2DM) had significantly lower Metrnl levels compared to the healthy controls.
Mlangeni, Angstone Thembachako; Vecchi, Valeria; Norton, Gareth J; Raab, Andrea; Krupp, Eva M; Feldmann, Joerg
2018-10-15
A commercial arsenic field kit designed to measure inorganic arsenic (iAs) in water was modified into a field deployable method (FDM) to measure iAs in rice. While the method has been validated to give precise and accurate results in the laboratory, its on-site field performance has not been evaluated. This study was designed to test the method on-site in Malawi in order to evaluate its accuracy and precision in determination of iAs on-site by comparing with a validated reference method and giving original data on inorganic arsenic in Malawian rice and rice-based products. The method was validated by using the established laboratory-based HPLC-ICPMS. Statistical tests indicated there were no significant differences between on-site and laboratory iAs measurements determined using the FDM (p = 0.263, ά = 0.05) and between on-site measurements and measurements determined using HPLC-ICP-MS (p = 0.299, ά = 0.05). This method allows quick (within 1 h) and efficient screening of rice containing iAs concentrations on-site. Copyright © 2018 Elsevier Ltd. All rights reserved.
Comparison of DNA extraction protocols for microbial communities from soil treated with biochar
Leite, D.C.A.; Balieiro, F.C.; Pires, C.A.; Madari, B.E.; Rosado, A.S.; Coutinho, H.L.C.; Peixoto, R.S.
2014-01-01
Many studies have evaluated the effects of biochar application on soil structure and plant growth. However, there are very few studies describing the effect of biochar on native soil microbial communities. Microbial analysis of environmental samples requires accurate and reproducible methods for the extraction of DNA from samples. Because of the variety among microbial species and the strong adsorption of the phosphate backbone of the DNA molecule to biochar, extracting and purifying high quality microbial DNA from biochar-amended soil is not a trivial process and can be considerably more difficult than the extraction of DNA from other environmental samples. The aim of this study was to compare the relative efficacies of three commercial DNA extraction kits, the FastDNA® SPIN Kit for Soil (FD kit), the PowerSoil® DNA Isolation Kit (PS kit) and the ZR Soil Microbe DNA Kit Miniprep™ (ZR kit), for extracting microbial genomic DNA from sand treated with different types of biochar. The methods were evaluated by comparing the DNA yields and purity and by analysing the bacterial and fungal community profiles generated by PCR-DGGE. Our results showed that the PCR-DGGE profiles for bacterial and fungal communities were highly affected by the purity and yield of the different DNA extracts. Among the tested kits, the PS kit was the most efficient with respect to the amount and purity of recovered DNA and considering the complexity of the generated DGGE microbial fingerprint from the sand-biochar samples. PMID:24948928
Comparison of DNA extraction protocols for microbial communities from soil treated with biochar.
Leite, D C A; Balieiro, F C; Pires, C A; Madari, B E; Rosado, A S; Coutinho, H L C; Peixoto, R S
2014-01-01
Many studies have evaluated the effects of biochar application on soil structure and plant growth. However, there are very few studies describing the effect of biochar on native soil microbial communities. Microbial analysis of environmental samples requires accurate and reproducible methods for the extraction of DNA from samples. Because of the variety among microbial species and the strong adsorption of the phosphate backbone of the DNA molecule to biochar, extracting and purifying high quality microbial DNA from biochar-amended soil is not a trivial process and can be considerably more difficult than the extraction of DNA from other environmental samples. The aim of this study was to compare the relative efficacies of three commercial DNA extraction kits, the FastDNA® SPIN Kit for Soil (FD kit), the PowerSoil® DNA Isolation Kit (PS kit) and the ZR Soil Microbe DNA Kit Miniprep™ (ZR kit), for extracting microbial genomic DNA from sand treated with different types of biochar. The methods were evaluated by comparing the DNA yields and purity and by analysing the bacterial and fungal community profiles generated by PCR-DGGE. Our results showed that the PCR-DGGE profiles for bacterial and fungal communities were highly affected by the purity and yield of the different DNA extracts. Among the tested kits, the PS kit was the most efficient with respect to the amount and purity of recovered DNA and considering the complexity of the generated DGGE microbial fingerprint from the sand-biochar samples.
30 CFR 7.411 - New technology.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false New technology. 7.411 Section 7.411 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF... Kits § 7.411 New technology. MSHA may approve cable products or splice kits that incorporate technology...
30 CFR 7.411 - New technology.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false New technology. 7.411 Section 7.411 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF... Kits § 7.411 New technology. MSHA may approve cable products or splice kits that incorporate technology...
30 CFR 7.411 - New technology.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false New technology. 7.411 Section 7.411 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF... Kits § 7.411 New technology. MSHA may approve cable products or splice kits that incorporate technology...
30 CFR 7.411 - New technology.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false New technology. 7.411 Section 7.411 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF... Kits § 7.411 New technology. MSHA may approve cable products or splice kits that incorporate technology...
Validation testing of a portable kit for measuring an active soil carbon fraction
Increasing demands exist for information about properties related to soil quality and human-induced soil change, particularly soil C. To help address this need, the USDA-NRCS Soil Survey Laboratory (SSL) developed a portable kit for rapid and relatively accurate assessment of soi...
30 CFR 7.411 - New technology.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false New technology. 7.411 Section 7.411 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF... Kits § 7.411 New technology. MSHA may approve cable products or splice kits that incorporate technology...
Method modification of the Legipid® Legionella fast detection test kit.
Albalat, Guillermo Rodríguez; Broch, Begoña Bedrina; Bono, Marisa Jiménez
2014-01-01
Legipid(®) Legionella Fast Detection is a test based on combined magnetic immunocapture and enzyme-immunoassay (CEIA) for the detection of Legionella in water. The test is based on the use of anti-Legionella antibodies immobilized on magnetic microspheres. Target microorganism is preconcentrated by filtration. Immunomagnetic analysis is applied on these preconcentrated water samples in a final test portion of 9 mL. The test kit was certified by the AOAC Research Institute as Performance Tested Method(SM) (PTM) No. 111101 in a PTM validation which certifies the performance claims of the test method in comparison to the ISO reference method 11731-1998 and the revision 11731-2004 "Water Quality: Detection and Enumeration of Legionella pneumophila" in potable water, industrial water, and waste water. The modification of this test kit has been approved. The modification includes increasing the target analyte from L. pneumophila to Legionella species and adding an optical reader to the test method. In this study, 71 strains of Legionella spp. other than L. pneumophila were tested to determine its reactivity with the kit based on CEIA. All the strains of Legionella spp. tested by the CEIA test were confirmed positive by reference standard method ISO 11731. This test (PTM 111101) has been modified to include a final optical reading. A methods comparison study was conducted to demonstrate the equivalence of this modification to the reference culture method. Two water matrixes were analyzed. Results show no statistically detectable difference between the test method and the reference culture method for the enumeration of Legionella spp. The relative level of detection was 93 CFU/volume examined (LOD50). For optical reading, the LOD was 40 CFU/volume examined and the LOQ was 60 CFU/volume examined. Results showed that the test Legipid Legionella Fast Detection is equivalent to the reference culture method for the enumeration of Legionella spp.
Ketone bodies - urine; Urine ketones; Ketoacidosis - urine ketones test; Diabetic ketoacidosis - urine ketones test ... Urine ketones are usually measured as a "spot test." This is available in a test kit that ...
Reichardt, Peter; Demetri, George D; Gelderblom, Hans; Rutkowski, Piotr; Im, Seock-Ah; Gupta, Sudeep; Kang, Yoon-Koo; Schöffski, Patrick; Schuette, Jochen; Soulières, Denis; Blay, Jean-Yves; Goldstein, David; Fly, Kolette; Huang, Xin; Corsaro, Massimo; Lechuga, Maria Jose; Martini, Jean-Francois; Heinrich, Michael C
2016-01-15
Several small studies indicated that the genotype of KIT or platelet-derived growth factor receptor-α (PDGFRA) contributes in part to the level of clinical effectiveness of sunitinib in gastrointestinal stromal tumor (GIST) patients. This study aimed to correlate KIT and PDGFRA mutational status with clinical outcome metrics (progression-free survival [PFS], overall survival [OS], objective response rate [ORR]) in a larger international patient population. This is a non-interventional, retrospective analysis in patients with imatinib-resistant or intolerant GIST who were treated in a worldwide, open-label treatment-use study (Study 1036; NCT00094029) in which sunitinib was administered at a starting dose of 50 mg/day on a 4-week-on, 2-week-off schedule. Molecular status was obtained in local laboratories with tumor samples obtained either pre-imatinib, post-imatinib/pre-sunitinib, or post-sunitinib treatment, and all available data were used in the analyses regardless of collection time. The primary analysis compared PFS in patients with primary KIT exon 11 versus exon 9 mutations (using a 2-sided log-rank test) and secondary analyses compared OS (using the same test) and ORR (using a 2-sided Pearson χ(2) test) in the same molecular subgroups. Of the 1124 sunitinib-treated patients in the treatment-use study, 230 (20%) were included in this analysis, and baseline characteristics were similar between the two study populations. Median PFS was 7.1 months. A significantly better PFS was observed in patients with a primary mutation in KIT exon 9 (n = 42) compared to those with a primary mutation in exon 11 (n = 143; hazard ratio = 0.59; 95 % confidence interval, 0.39-0.89; P = 0.011), with median PFS times of 12.3 and 7.0 months, respectively. Similarly, longer OS and higher ORR were observed in patients with a primary KIT mutation in exon 9 versus exon 11. The data available were limited to investigate the effects of additional KIT or PDGFRA mutations on the efficacy of sunitinib treatment. This large retrospective analysis confirms the prognostic significance of KIT mutation status in patients with GIST. This analysis also confirms the effectiveness of sunitinib as a post-imatinib therapy, regardless of mutational status. NCT01459757.
Targeting Low-arsenic Groundwater with Mobile-phone Technology in Araihazar, Bangladesh
Trevisani, M.; Immel, J.; Jakariya, Md.; Osman, N.; Cheng, Z.; Gelman, A.; Ahmed, K.M.
2006-01-01
The Bangladesh Arsenic Mitigation and Water Supply Program (BAMWSP) has compiled field-kit measurements of the arsenic content of groundwater for nearly five million wells. By comparing the spatial distribution of arsenic inferred from these field-kit measurements with geo-referenced laboratory data in a portion of Araihazar upazila, it is shown here that the BAMWSP data could be used for targeting safe aquifers for the installation of community wells in many villages of Bangladesh. Recent experiences with mobile-phone technology to access and update the BAMWSP data in the field are also described. It is shown that the technology, without guaranteeing success, could optimize interventions by guiding the choice of the drilling method that is likely to reach a safe aquifer and identifying those villages where exploratory drilling is needed. PMID:17366770
2008 Tactical Wheeled Vehicles Conference (TWV) Volume 3
2008-02-05
Armor/ GPK OTHER SIGNIFICANT PROCUREMENT EFFORTS Project Manager COL Scott R. Kidd Deputy PM Acquisition: Tony Shaw Deputy PM Logistics: Cesare Gaglio r...Support Modularity/ Grow the Army Full spectrum support to the War Fight & Modularity LSACM1117 ASV Production Frag Kit 5/ GPK TPE Refurb Gunner Restraint...Harness HEMTT AoA LSAC Production Objective – Gunner Protection Kit (O- GPK ) HMMWV HTV FMTV M1151/52 20 3 CSL PMs ~ Approximately 220K Systems Fielded
Management System for Engineering Ethics
NASA Astrophysics Data System (ADS)
Yashiro, Tomonari
In the context of independent profession based societies, ethics charter/codes of professional bodies have significant influence on the conduct of engineers. Contrarily in Japan, most of active engineers are in-house and feel immediate identity as the member of firm or institution, rather than professional bodies. Therefore, establishment and operation of engineering ethics management system (E2ms) is essential for incentive to make innovative and ethical decision with confidence. The paper introduces the outline of the educational kit for E2ms developed by the author. The kit aims to enhance ability of management relevant to E2ms. The kit also involves ten cases for case method teaching. The test use of the kit indicates the potential to create satisfactory educational achievement.
Picard-Meyer, Evelyne; Peytavin de Garam, Carine; Schereffer, Jean Luc; Marchal, Clotilde; Robardet, Emmanuelle; Cliquet, Florence
2015-01-01
This study evaluates the performance of five two-step SYBR Green RT-qPCR kits and five one-step SYBR Green qRT-PCR kits using real-time PCR assays. Two real-time thermocyclers showing different throughput capacities were used. The analysed performance evaluation criteria included the generation of standard curve, reaction efficiency, analytical sensitivity, intra- and interassay repeatability as well as the costs and the practicability of kits, and thermocycling times. We found that the optimised one-step PCR assays had a higher detection sensitivity than the optimised two-step assays regardless of the machine used, while no difference was detected in reaction efficiency, R (2) values, and intra- and interreproducibility between the two methods. The limit of detection at the 95% confidence level varied between 15 to 981 copies/µL and 41 to 171 for one-step kits and two-step kits, respectively. Of the ten kits tested, the most efficient kit was the Quantitect SYBR Green qRT-PCR with a limit of detection at 95% of confidence of 20 and 22 copies/µL on the thermocyclers Rotor gene Q MDx and MX3005P, respectively. The study demonstrated the pivotal influence of the thermocycler on PCR performance for the detection of rabies RNA, as well as that of the master mixes.
Picard-Meyer, Evelyne; Peytavin de Garam, Carine; Schereffer, Jean Luc; Marchal, Clotilde; Robardet, Emmanuelle; Cliquet, Florence
2015-01-01
This study evaluates the performance of five two-step SYBR Green RT-qPCR kits and five one-step SYBR Green qRT-PCR kits using real-time PCR assays. Two real-time thermocyclers showing different throughput capacities were used. The analysed performance evaluation criteria included the generation of standard curve, reaction efficiency, analytical sensitivity, intra- and interassay repeatability as well as the costs and the practicability of kits, and thermocycling times. We found that the optimised one-step PCR assays had a higher detection sensitivity than the optimised two-step assays regardless of the machine used, while no difference was detected in reaction efficiency, R 2 values, and intra- and interreproducibility between the two methods. The limit of detection at the 95% confidence level varied between 15 to 981 copies/µL and 41 to 171 for one-step kits and two-step kits, respectively. Of the ten kits tested, the most efficient kit was the Quantitect SYBR Green qRT-PCR with a limit of detection at 95% of confidence of 20 and 22 copies/µL on the thermocyclers Rotor gene Q MDx and MX3005P, respectively. The study demonstrated the pivotal influence of the thermocycler on PCR performance for the detection of rabies RNA, as well as that of the master mixes. PMID:25785274
Garmer, Karin; Sperling, Lena; Forsberg, Anette
2002-01-01
A need for a hand-ergonomics training kit has been identified to increase critical thinking concerning choice of hand tools. This study deals with the design, use and evaluation of a hand-ergonomics training kit for use in ergonomics training programmes. The effects on awareness of hand ergonomics among training course participants have been evaluated by means of a questionnaire and interviews at a car production plant in Sweden. The evaluation was carried out about one and a half years after training with the hand-ergonomics training kit. The training kit consists of a guide to practical exercises, equipment for measuring hand size and strength, examples of hand tools for use in practical exercises, equipment for testing and evaluating the hand tools and checklists and judgement forms for qualitative evaluation. In addition, the kit contains relevant scientifically based reference reports on hand ergonomics. The evaluation showed that the practical exercises with the hand-ergonomic training kit had, to a remarkable extent, increased individuals' awareness of anthropometric differences and of the importance of ergonomically well-designed hand tools. After the practical exercises with the training kit, communication within the plant when choosing hand tools seems to be based on objective criteria to a higher degree, however, the results indicate that this communication could be further improved.
Hansen, Frank; Hammerum, Anette M; Skov, Robert; Haldorsen, Bjørg; Sundsfjord, Arnfinn; Samuelsen, Orjan
2014-08-01
Phenotypic tests for carbapenemase production in Pseudomonas aeruginosa and Acinetobacter baumannii have been associated with unspecific metallo-β-lactamase (MBL) inhibitor activity in synergy tests and low positive predictive value. In this study, a collection of well-characterized P. aeruginosa and A. baumannii isolates was used to evaluate the inhibitor-based Total MBL Confirm Kit and the MBL Etest. Copyright © 2014 Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Dunn, Lloyd M.; Mueller, Max W.
The differential effects of the experimental revision of Level 1 of the Peabody Language Development Kits (PLDK) on the Illinois Test of Psycholinguistic Abilities (ITPA) profiles of disadvantaged first-grade children were studied. Contrasted with 203 control subjects were 529 experimental subjects who received a daily 30-minute oral language…
Wall, Jason; Conrad, Rick; Latham, Kathy; Liu, Eric
2014-03-01
Real-time PCR methods for detecting foodborne pathogens offer the advantages of simplicity and quick time to results compared to traditional culture methods. The addition of a recirculating pooled immunomagnetic separation method prior to real-time PCR analysis increases processing output while reducing both cost and labor. This AOAC Research Institute method modification study validates the MicroSEQ® Salmonella spp. Detection Kit [AOAC Performance Tested Method (PTM) 031001] linked with the Pathatrix® 10-Pooling Salmonella spp. Kit (AOAC PTM 090203C) in diced tomatoes, chocolate, and deli ham. The Pathatrix 10-Pooling protocol represents a method modification of the enrichment portion of the MicroSEQ Salmonella spp. The results of the method modification were compared to standard cultural reference methods for diced tomatoes, chocolate, and deli ham. All three matrixes were analyzed in a paired study design. An additional set of chocolate test portions was analyzed using an alternative enrichment medium in an unpaired study design. For all matrixes tested, there were no statistically significant differences in the number of positive test portions detected by the modified candidate method compared to the appropriate reference method. The MicroSEQ Salmonella spp. protocol linked with the Pathatrix individual or 10-Pooling procedure demonstrated reliability as a rapid, simplified, method for the preparation of samples and subsequent detection of Salmonella in diced tomatoes, chocolate, and deli ham.
Jung, Ju Yeon; Kim, Eun Hye; Oh, Yu-Li; Park, Hyun-Chul; Hwang, Jung Ho; Lim, Si-Keun
2017-09-01
We genotyped and calculated the forensic parameters of 10 non-CODIS loci and 2 CODIS loci of 990 Korean individuals using the Investigator Ⓡ HDplex kit. No significant deviations from Hardy-Weinberg equilibrium (after Bonferroni correction for multiple testing) or genetic linkage disequilibrium were observed. The calculated matching probability and power of discrimination ranged from 0.0080 to 0.2014, and 0.7986 to 0.9920, respectively. We conclude that the markers of the kit are highly informative corroborative tools for forensic DNA analysis.
Franklin, S.P.; Troyer, J.L.; TerWee, J.A.; Lyren, L.M.; Kays, R.W.; Riley, S.P.D.; Boyce, W.M.; Crooks, K.R.; VandeWoude, S.
2007-01-01
Although lentiviruses similar to feline immunodeficiency virus (FIV) are known to infect numerous felid species, the relative utility of assays used for detecting lentiviral infection has not been compared for many of these hosts. We tested bobcats (Lynx rufus), pumas (Felis concolor), and ocelots (Leopardus pardalis) for exposure to lentivirus using five different assays: puma lentivirus (PLV), African lion lentivirus (LLV), and domestic cat FIV-based immunoblots, a commercially available enzyme-linked immunosorbent assay (ELISA) kit, and nested polymerase chain reaction (PCR). Puma lentivirus immunoblots identified more seropositive individuals than the other antibody-detection assays. The commercial ELISA provided a fair ability to recognize seropositive samples when compared with PLV immunoblot for screening bobcats and ocelots, but not pumas. Polymerase chain reaction identified fewer positive samples than PLV immunoblot for all three species. Immunoblot results were equivalent whether the sample tested was serum, plasma, or whole blood. The results from this study and previous investigations suggest that the PLV immunoblot has the greatest ability to detect reactive samples when screening wild felids of North America and is unlikely to produce false positive results. However, the commercial ELISA kit may provide ap adequate alternative for screening of some species and is more easily adapted to field conditions. ?? Wildlife Disease Association 2007.
Fuel Economy and Emissions of a Vehicle Equipped with an Aftermarket Flexible-Fuel Conversion Kit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thomas, John F; Huff, Shean P; West, Brian H
2012-04-01
The U.S. Environmental Protection Agency (EPA) grants Certificates of Conformity for alternative fuel conversion systems and also offers other forms of premarket registration of conversion kits for use in vehicles more than two model years old. Use of alternative fuels such as ethanol, natural gas, and propane are encouraged by the Energy Policy Act of 1992. Several original equipment manufacturers (OEMs) produce emissions-certified vehicles capable of using alternative fuels, and several alternative fuel conversion system manufacturers produce EPA-approved conversion systems for a variety of alternative fuels and vehicle types. To date, only one manufacturer (Flex Fuel U.S.) has received EPAmore » certifications for ethanol fuel (E85) conversion kits. This report details an independent evaluation of a vehicle with a legal installation of a Flex Fuel U.S. conversion kit. A 2006 Dodge Charger was baseline tested with ethanol-free certification gasoline (E0) and E20 (gasoline with 20 vol % ethanol), converted to flex-fuel operation via installation of a Flex Box Smart Kit from Flex Fuel U.S., and retested with E0, E20, E50, and E81. Test cycles included the Federal Test Procedure (FTP or city cycle), the highway fuel economy test (HFET), and the US06 test (aggressive driving test). Averaged test results show that the vehicle was emissions compliant on E0 in the OEM condition (before conversion) and compliant on all test fuels after conversion. Average nitrogen oxide (NOx) emissions exceeded the Tier 2/Bin 5 intermediate life NO{sub X} standard with E20 fuel in the OEM condition due to two of three test results exceeding this standard [note that E20 is not a legal fuel for non-flexible-fuel vehicles (non-FFVs)]. In addition, one E0 test result before conversion and one E20 test result after conversion exceeded the NOX standard, although the average result in these two cases was below the standard. Emissions of ethanol and acetaldehyde increased with increasing ethanol, while nonmethane organic gas and CO emissions remained relatively unchanged for all fuels and cycles. Higher fraction ethanol blends appeared to decrease NO{sub X} emissions on the FTP and HFET (after conversion). As expected, fuel economy (miles per gallon) decreased with increasing ethanol content in all cases.« less
Arsenic exposure in drinking water: an unrecognized health threat in Peru
Sima, Laura; Arias, M Helena Jahuira; Mihalic, Jana; Cabrera, Lilia Z; Danz, David; Checkley, William; Gilman, Robert H
2014-01-01
Abstract Objective To assess the extent of arsenic contamination of groundwater and surface water in Peru and, to evaluate the accuracy of the Arsenic Econo-Quick™ (EQ) kit for measuring water arsenic concentrations in the field. Methods Water samples were collected from 151 water sources in 12 districts of Peru, and arsenic concentrations were measured in the laboratory using inductively-coupled plasma mass spectrometry. The EQ field kit was validated by comparing a subset of 139 water samples analysed by laboratory measurements and the EQ kit. Findings In 86% (96/111) of the groundwater samples, arsenic exceeded the 10 µg/l arsenic concentration guideline given by the World Health Organization (WHO) for drinking water. In 56% (62/111) of the samples, it exceeded the Bangladeshi threshold of 50 µg/l; the mean concentration being 54.5 µg/l (range: 0.1–93.1). In the Juliaca and Caracoto districts, in 96% (27/28) of groundwater samples arsenic was above the WHO guideline; and in water samples collected from the section of the Rímac river running through Lima, all had arsenic concentrations exceeding the WHO limit. When validated against laboratory values, the EQ kit correctly identified arsenic contamination relative to the guideline in 95% (106/111) of groundwater and in 68% (19/28) of surface water samples. Conclusion In several districts of Peru, drinking water shows widespread arsenic contamination, exceeding the WHO arsenic guideline. This poses a public health threat requiring further investigation and action. For groundwater samples, the EQ kit performed well relative to the WHO arsenic limit and therefore could provide a vital tool for water arsenic surveillance. PMID:25177071
Tegbaru, Belete; Messele, Tsehaynesh; Wolday, Dawit; Meles, PhD Hailu; Tesema, Desalegn; Birhanu, Hiwot; Tesfaye, Girma; Bond, Kyle B; Martin, Robert; Rayfield, Mark A; Wuhib, Tadesse; Fekadu, Makonnen
2004-10-01
Five simple and rapid HIV antibody detection assays viz. Determine, Capillus, Oraquick, Unigold and Hemastrip were evaluated to examine their performance and to develop an alternative rapid test based testing algorithm for voluntary counseling and testing (VCT) in Ethiopia. All the kits were tested on whole blood, plasma and serum. The evaluation had three phases: Primary lab review, piloting at point of service and implementation. This report includes the results of the first two phases. A total of 2,693 specimens (both whole blood and plasma) were included in the evaluation. Results were compared to double Enzyme Linked Immuno-Sorbent Assay (ELISA) system. Discordant EIA results were resolved using Western Blot. The assays had very good sensitivities and specificities, 99-100%, at the two different phases of the evaluation. A 98-100% result agreement was obtained from those tested at VCT centers and National Referral Laboratory for AIDS (NRLA), in the quality control phase of the evaluation. A testing strategy yielding 100% [95% CI; 98.9-100.0] sensitivity was achieved by the sequential use of the three rapid test kits. Direct cost comparison showed serial testing algorithm reduces the cost of testing by over 30% compared to parallel testing in the current situation. Determine, Capillus/Oraquick (presence/absence of frefrigeration) and Unigold were recommended as screening, confirmation and tiebreaker tests, respectively.
Athanasiou, Labrini V; Petanides, Theodoros A; Chatzis, Manolis K; Kasabalis, Dimitrios; Apostolidis, Kosmas N; Saridomichelakis, Manolis N
2014-03-01
Antibodies against Leishmania spp. are detected in most dogs with clinical signs of leishmaniasis due to Leishmania infantum. Accurate, rapid in-clinic serological tests may permit immediate confirmation of the diagnosis and implementation of therapeutic measures. The aim of the current study was to evaluate the diagnostic accuracy of 2 commercial, rapid in-clinic serological tests for the detection of anti-Leishmania antibodies in sera of dogs, the Snap Canine Leishmania Antibody Test kit (IDEXX Laboratories Inc., Westbrook, Maine) and the ImmunoRun Antibody Detection kit (Biogal Galed Labs, Kibbutz Galed, Israel), using indirect fluorescent antibody test (IFAT) as the reference method. A total of 109 sera collected from 65 seropositive and 44 seronegative dogs were used. The sensitivities of the Snap and ImmunoRun kits were 89.23% (95% confidence interval: 79.05-95.54%) and 86.15% (95% confidence interval: 75.33-93.45%), respectively, and the specificity of both tests was 100%. A good agreement between each of the rapid in-clinic serological tests and IFAT and between the 2 rapid in-clinic serological tests was witnessed. Both rapid in-clinic serological tests showed an adequate diagnostic accuracy and can be used for the fast detection of antibodies against L. infantum in dogs.
Evaluation of three high abundance protein depletion kits for umbilical cord serum proteomics
2011-01-01
Background High abundance protein depletion is a major challenge in the study of serum/plasma proteomics. Prior to this study, most commercially available kits for depletion of highly abundant proteins had only been tested and evaluated in adult serum/plasma, while the depletion efficiency on umbilical cord serum/plasma had not been clarified. Structural differences between some adult and fetal proteins (such as albumin) make it likely that depletion approaches for adult and umbilical cord serum/plasma will be variable. Therefore, the primary purposes of the present study are to investigate the efficiencies of several commonly-used commercial kits during high abundance protein depletion from umbilical cord serum and to determine which kit yields the most effective and reproducible results for further proteomics research on umbilical cord serum. Results The immunoaffinity based kits (PROTIA-Sigma and 5185-Agilent) displayed higher depletion efficiency than the immobilized dye based kit (PROTBA-Sigma) in umbilical cord serum samples. Both the PROTIA-Sigma and 5185-Agilent kit maintained high depletion efficiency when used three consecutive times. Depletion by the PROTIA-Sigma Kit improved 2DE gel quality by reducing smeared bands produced by the presence of high abundance proteins and increasing the intensity of other protein spots. During image analysis using the identical detection parameters, 411 ± 18 spots were detected in crude serum gels, while 757 ± 43 spots were detected in depleted serum gels. Eight spots unique to depleted serum gels were identified by MALDI- TOF/TOF MS, seven of which were low abundance proteins. Conclusions The immunoaffinity based kits exceeded the immobilized dye based kit in high abundance protein depletion of umbilical cord serum samples and dramatically improved 2DE gel quality for detection of trace biomarkers. PMID:21554704
KIT amplification and gene mutations in acral/mucosal melanoma in Korea.
Yun, Jina; Lee, Jeeyun; Jang, Jiryeon; Lee, Eui Jin; Jang, Kee Taek; Kim, Jung Han; Kim, Kyoung-Mee
2011-06-01
Mucosal and acral melanomas have demonstrated different genetic alterations and biological behavior compared with more common cutaneous melanomas. It was recently reported that gain-of-function KIT mutations and/or copy number increases are more common in mucosal and acral melanomas. Thus, we studied the frequency and pattern of KIT aberrations in mucosal and acral melanomas in Korea. We analyzed 97 patients who were pathologically confirmed with mucosal or acral melanoma between 1997 and 2010 at Samsung Medical Center. Of the 97 melanoma patients, 92 were screened for mutations in KIT exons 11, 13, 17, and 18, BRAF and NRAS genes. KIT copy number was assessed by quantitative, real-time PCR. Of the 97 patients, 55 (56.7%) were mucosal, 40 (41.2%) were acral melanoma, and two were of unknown primary origin. Among seven cases with KIT mutation, five (60.0%) occurred in exon 11, one (20.0%) in exon 17, and one (20.0%) in exon 13. Point mutations were the most common, resulting in substitutions in exon 11 (K558R, T574A, L576P, and V559A), exon 13 (N655K), and exon 17 (N822K). A novel Thr574Ala (c.1720A>G) KIT mutation, which has not been reported in melanoma or other tumor types, was identified in one genital melanoma case. Of the 97 mucosal or acral melanoma specimens, 49 were tested for KIT gene copy number changes using quantitative PCR. Increased KIT copy number was identified in 15 patients: seven (40%) of 20 acral melanomas and eight (31%) of 26 mucosal melanomas. Our study implicates that a significant proportion of acral and mucosal melanomas have KIT mutations in Asian population. © 2011 The Authors. APMIS © 2011 APMIS.
Gebreyohannes, Yemarshet K; Schöffski, Patrick; Van Looy, Thomas; Wellens, Jasmien; Vreys, Lise; Cornillie, Jasmien; Vanleeuw, Ulla; Aftab, Dana T; Debiec-Rychter, Maria; Sciot, Raf; Wozniak, Agnieszka
2016-12-01
In the majority of gastrointestinal stromal tumors (GIST), oncogenic signaling is driven by KIT mutations. Advanced GIST is treated with tyrosine kinase inhibitors (TKI) such as imatinib. Acquired resistance to TKI is mainly caused by secondary KIT mutations, but can also be attributed to a switch of KIT dependency to another receptor tyrosine kinase (RTK). We tested the efficacy of cabozantinib, a novel TKI targeting KIT, MET, AXL, and vascular endothelial growth factor receptors (VEGFR), in patient-derived xenograft (PDX) models of GIST, carrying different KIT mutations. NMRI nu/nu mice (n = 52) were bilaterally transplanted with human GIST: UZLX-GIST4 (KIT exon 11 mutation, imatinib sensitive), UZLX-GIST2 (KIT exon 9, imatinib dose-dependent resistance), or UZLX-GIST9 (KIT exon 11 and 17 mutations, imatinib resistant). Mice were grouped as control (untreated), imatinib (50 mg/kg/bid), and cabozantinib (30 mg/kg/qd) and treated orally for 15 days. Cabozantinib resulted in significant tumor regression in UZLX-GIST4 and -GIST2 and delayed tumor growth in -GIST9. In all three models, cabozantinib inhibited the proliferative activity, which was completely absent in UZLX-GIST4 and significantly reduced in -GIST2 and -GIST9. Increased apoptotic activity was observed only in UZLX-GIST4. Cabozantinib inhibited the KIT signaling pathway in UZLX-GIST4 and -GIST2. In addition, compared with both control and imatinib, cabozantinib significantly reduced microvessel density in all models. In conclusion, cabozantinib showed antitumor activity in GIST PDX models through inhibition of tumor growth, proliferation, and angiogenesis, in both imatinib-sensitive and imatinib-resistant models. Mol Cancer Ther; 15(12); 2845-52. ©2016 AACR. ©2016 American Association for Cancer Research.
Steiner, René; Beier, Ulrike S; Heiss-Kisielewsky, Irene; Engelmeier, Robert; Dumfahrt, Herbert; Dhima, Matilda
2015-06-01
During the insertion appointment, the practitioner is often faced with the need to adjust ceramic surfaces to fit a restoration to the adjacent or opposing dentition and soft tissues. The purpose of this study was to assess the ceramic surface smoothness achieved with various commercially available ceramic polishing kits on different commonly used ceramic systems. The reliability of the cost of a polishing kit as an indicator of improved surface smoothness was assessed. A total of 350 ceramic surfaces representing 5 commonly available ceramic systems (IPS Empress Esthetic, IPS e.max Press, Cergo Kiss, Vita PM 9, Imagine PressX) were treated with 5 types of ceramic polishing systems (Cerapreshine, 94006C, Ceramiste, Optrafine, Zenostar) by following the manufacturers' guidelines. The surface roughness was measured with a profilometer (Taylor Hobson; Precision Taylor Hobson Ltd). The effects of ceramic systems and polishing kits of interest on surface roughness were analyzed by 2-way ANOVA, paired t test, and Bonferroni corrected significance level. The ceramic systems and polishing kits statistically affected surface roughness (P<.001).The polishing kit Zenostar on IPS e.max Press created the smoothest ceramic surface. No correlation could be established between the high cost of the polishing kit and low surface roughness. None of the commonly used ceramic polishing kits could create a surface smoother than that of glazed ceramic (P<.001). The inclusion of a diamond polishing paste step is recommended to improve surface smoothness (P<.001). The cost of ceramic polishing kits is not recommended as a reliable indicator of better performance of ceramic polishing kits (P>.30). Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Evaluation of ELISA tests specific for Shiga toxin 1 and 2 in food and water samples
USDA-ARS?s Scientific Manuscript database
Two enzyme-linked immunosorbent assay (ELISA) kits were evaluated for their effectiveness in detecting and differentiating between Shiga toxin 1 and 2 (Stx1 and Stx2) produced by Shiga toxin-producing E. coli (STEC) inoculated into food and water samples. Each kit incorporated monoclonal antibodies ...
Design, Certification, and Deployment of the Colorimetric Water Quality Monitoring Kit (CWQMK)
NASA Technical Reports Server (NTRS)
Gazda, Daniel B.; Nolan, Daniel J.; Rutz, Jeff A.; Schultz, John R.; Siperko, Lorraine M.; Porter, Marc D.; Lipert, Robert J.; Carrizales, Stephanie M.; McCoy, J. Torin
2009-01-01
In August 2009, an experimental water quality monitoring kit based on Colorimetric Solid Phase Extraction (CSPE) technology was delivered to the International Space Station (ISS) aboard STS-128/17A. The kit, called the Colorimetric Water Quality Monitoring Kit (CWQMK), was developed by a team of scientists and engineers from NASA s Habitability and Environmental Factors Division in the Space Life Sciences Directorate at Johnson Space Center, the Wyle Integrated Science and Engineering Group in Houston, Texas, the University of Utah, and Iowa State University. The CWQMK was flown and deployed as a Station Development Test Objective (SDTO) experiment on ISS. The goal of the SDTO experiment was to evaluate the acceptability of CSPE technology for routine water quality monitoring on ISS. This paper provides an overview of the SDTO experiment, as well as a detailed description of the CWQMK hardware and a summary of the testing and analysis conducted to certify the CWQMK for use on ISS. The results obtained from the SDTO experiment are also reported and discussed in detail.
Dortet, Laurent; Tandé, Didier; de Briel, Dominique; Bernabeu, Sandrine; Lasserre, Camille; Gregorowicz, Guillaume; Jousset, Agnès B; Naas, Thierry
2018-06-11
There is an urgent need for accurate and fast diagnostic tests to identify carbapenemase-producing bacteria. Here, we have evaluated three MALDI-TOF-based techniques to detect carbapenemase-producing Enterobacteriaceae (CPE) from cultured colonies. The performance of three MALDI-TOF-based techniques, including the commercialized MBT STAR®-Carba IVD Kit (Bruker Daltonics) and two in-house protocols performed on the Microflex LT Biotyper (Bruker Daltonics) and the VITEK® MS Plus (bioMérieux), were compared with those of the RAPIDEC® CARBA NP (bioMérieux). A collection of 175 isolates including 120 carbapenemase producers and 55 non-carbapenemase producers was tested. Samples were tested blind in the three participating centres. The repeatability of the MBT STAR®-Carba IVD Kit was also evaluated. The three MALDI-TOF techniques possess sensitivities ranging from 95% to 100% and specificities from 98.2% to 100% compared with 99.2% and 100%, respectively, for the RAPIDEC® CARBA NP. The MBT STAR®-Carba IVD Kit gave highly reproducible results and is the only technique able to provide a concomitant identification of the bacterial isolate. The three MALDI-TOF techniques possess a fast turnaround time (less than 1.5 h). Overall, MALDI-TOF is a reliable technique for the rapid detection of CPE from cultured colonies. MBT STAR®-Carba IVD Kit, the only commercially available assay, could easily be implemented in a clinical microbiology laboratory if it is already equipped with a Microflex LT Biotyper mass spectrometer.
Comparison of DNA extraction methods for human gut microbial community profiling.
Lim, Mi Young; Song, Eun-Ji; Kim, Sang Ho; Lee, Jangwon; Nam, Young-Do
2018-03-01
The human gut harbors a vast range of microbes that have significant impact on health and disease. Therefore, gut microbiome profiling holds promise for use in early diagnosis and precision medicine development. Accurate profiling of the highly complex gut microbiome requires DNA extraction methods that provide sufficient coverage of the original community as well as adequate quality and quantity. We tested nine different DNA extraction methods using three commercial kits (TianLong Stool DNA/RNA Extraction Kit (TS), QIAamp DNA Stool Mini Kit (QS), and QIAamp PowerFecal DNA Kit (QP)) with or without additional bead-beating step using manual or automated methods and compared them in terms of DNA extraction ability from human fecal sample. All methods produced DNA in sufficient concentration and quality for use in sequencing, and the samples were clustered according to the DNA extraction method. Inclusion of bead-beating step especially resulted in higher degrees of microbial diversity and had the greatest effect on gut microbiome composition. Among the samples subjected to bead-beating method, TS kit samples were more similar to QP kit samples than QS kit samples. Our results emphasize the importance of mechanical disruption step for a more comprehensive profiling of the human gut microbiome. Copyright © 2017 The Authors. Published by Elsevier GmbH.. All rights reserved.
Analysis of direct-to-consumer marketed Chlamydia trachomatis diagnostic tests in Norway.
Reinton, Nils; Hjelmevoll, Stig Ove; Håheim, Håkon; Garstad, Kjersti; Mørch-Reiersen, Lisa Therese; Moghaddam, Amir
2015-08-01
Background In 2014, and for the first time in Norway, a pharmacy chain started selling home sampling kits for Chlamydia trachomatis (C. trachomatis) detection. Direct-to-consumer diagnostic kits for C. trachomatis have been available in Norway from an Internet company since 2005. There has been little assessment of persons who purchase direct-to-consumer diagnostic tests for sexually transmissible infections (STIs) detection and if low-risk populations are being unnecessarily encouraged to buy these tests. The prevalence of C. trachomatis in customers who purchased home sampling kits from the pharmacy chain and from the commercial Internet Co. were compared to that of patients attending STI clinics and other free primary healthcare services. Prevalences of other STIs in pharmacy and Internet customers were also determined. The prevalence of C. trachomatis among pharmacy customers was 11%, almost identical to the prevalence among Internet customers (12%). In comparison, the prevalence among patients attending STI clinics in Oslo was 7.2%, which is similar to the prevalence among patients who have been tested through primary healthcare services. The prevalence of Mycoplasma genitalium was two-fold less than that of C. trachomatis in the STI and primary physician population, and significantly less in the Internet and the pharmacy population. Neisseria gonorrhoeae was not detected in urine samples from pharmacy customers or from Internet customers. Both pharmacy and Internet C. trachomatis home-sampling kits seem to be purchased by the right risk population. Marketing of direct-to-consumer N. gonorrhoeae tests and possibly M. genitalium tests cannot be justified in Norway. Direct-to-consumer diagnostic tests should be actively utilised as part of national programs in preventing the spread of C. trachomatis.
Yousuf, R; Abdul Ghani, S A; Abdul Khalid, N; Leong, C F
2018-04-01
'InTec Blood Grouping Test kit' using solid-phase technology is a new method which may be used at outdoor blood donation site or at bed side as an alternative to the conventional tile method in view of its stability at room temperature and fulfilled the criteria as point of care test. This study aimed to compare the efficiency of this solid phase method (InTec Blood Grouping Test Kit) with the conventional tile method in determining the ABO and RhD blood group of healthy donors. A total of 760 voluntary donors who attended the Blood Bank, Penang Hospital or offsite blood donation campaigns from April to May 2014 were recruited. The ABO and RhD blood groups were determined by the conventional tile method and the solid phase method, in which the tube method was used as the gold standard. For ABO blood grouping, the tile method has shown 100% concordance results with the gold standard tube method, whereas the solid-phase method only showed concordance result for 754/760 samples (99.2%). Therefore, for ABO grouping, tile method has 100% sensitivity and specificity while the solid phase method has slightly lower sensitivity of 97.7% but both with good specificity of 100%. For RhD grouping, both the tile and solid phase methods have grouped one RhD positive specimen as negative each, thus giving the sensitivity and specificity of 99.9% and 100% for both methods respectively. The 'InTec Blood Grouping Test Kit' is suitable for offsite usage because of its simplicity and user friendliness. However, further improvement in adding the internal quality control may increase the test sensitivity and validity of the test results.
Murayama, Asako; Sugiyama, Nao; Watashi, Koichi; Masaki, Takahiro; Suzuki, Ryosuke; Aizaki, Hideki; Mizuochi, Toshiaki; Wakita, Takaji
2012-01-01
An accurate and reliable quantitative assay for hepatitis C virus (HCV) is essential for measuring viral propagation and the efficacy of antiviral therapy. There is a growing need for domestic reference panels for evaluation of clinical assay kits because the performance of these kits may vary with region-specific genotypes or polymorphisms. In this study, we established a reference panel by selecting 80 donated blood specimens in Japan that tested positive for HCV. Using this panel, we quantified HCV viral loads using two HCV RNA kits and five core antigen (Ag) kits currently available in Japan. The data from the two HCV RNA assay kits showed excellent correlation. All RNA titers were distributed evenly across a range from 3 to 7 log IU/ml. Although the data from the five core Ag kits also correlated with RNA titers, the sensitivities of individual kits were not sufficient to quantify viral load in all samples. As calculated by the correlation with RNA titers, the theoretical lower limits of detection by these core Ag assays were higher than those for the detection of RNA. Moreover, in several samples in our panel, core Ag levels were underestimated compared to RNA titers. Sequence analysis in the HCV core region suggested that polymorphisms at amino acids 47 to 49 of the core Ag were responsible for this underestimation. The panel established in this study will be useful for estimating the quality of currently available and upcoming HCV assay kits; such quality control is essential for clinical usage of these kits. PMID:22495557
Moura, David S; Ramos, Rafael; Fernandez-Serra, Antonio; Serrano, Teresa; Cruz, Julia; Alvarez-Alegret, Ramiro; Ortiz-Duran, Rosa; Vicioso, Luis; Gomez-Dorronsoro, Maria Luisa; Garcia Del Muro, Xavier; Martinez-Trufero, Javier; Rubio-Casadevall, Jordi; Sevilla, Isabel; Lainez, Nuria; Gutierrez, Antonio; Serrano, Cesar; Lopez-Alvarez, Maria; Hindi, Nadia; Taron, Miguel; López-Guerrero, José Antonio; Martin-Broto, Javier
2018-04-03
There are limited findings available on KIT-negative GIST-like (KNGL) population. Also, KIT expression may be post-transcriptionally regulated by miRNA221 and miRNA222. Hence, the aim of this study is to characterize KNGL population, by differential gene expression, and to analyze miRNA221/222 expression and their prognostic value in KNGL patients. KIT , PDGFRA , DOG1 , IGF1R , MIR221 and MIR222 expression levels were determined by qRT-PCR. We also analyzed KIT and PDGFRA mutations, DOG1 expression, by immunohistochemistry, along with clinical and pathological data. Disease-free survival (DFS) and overall survival (OS) differences were calculated using Log-rank test. Hierarchical cluster analyses from gene expression data identified two groups: group I had KIT , DOG1 and PDGFRA overexpression and IGF1R underexpression and group II had overexpression of IGF1R and low expression of KIT , DOG1 and PDGFRA . Group II had a significant worse OS ( p = 0.013) in all the series, and showed a tendency for worse OS ( p = 0.11), when analyzed only the localized cases. MiRNA222 expression was significantly lower in a control subset of KIT-positive GIST ( p < 0.001). OS was significantly worse in KNGL cases with higher expression of MIR221 ( p = 0.028) or MIR222 ( p = 0.014). We identified two distinct KNGL subsets, with a different prognostic value. Increased levels of miRNA221/222, which are associated with worse OS, could explain the absence of KIT protein expression of most KNGL tumors.
Evaluating the Medical Kit System for the International Space Station(ISS) - A Paradigm Revisited
NASA Technical Reports Server (NTRS)
Hailey, Melinda J.; Urbina, Michelle C.; Hughlett, Jessica L.; Gilmore, Stevan; Locke, James; Reyna, Baraquiel; Smith, Gwyn E.
2010-01-01
Medical capabilities aboard the International Space Station (ISS) have been packaged to help astronaut crew medical officers (CMO) mitigate both urgent and non-urgent medical issues during their 6-month expeditions. Two ISS crewmembers are designated as CMOs for each 3-crewmember mission and are typically not physicians. In addition, the ISS may have communication gaps of up to 45 minutes during each orbit, necessitating medical equipment that can be reliably operated autonomously during flight. The retirement of the space shuttle combined with ten years of manned ISS expeditions led the Space Medicine Division at the NASA Johnson Space Center to reassess the current ISS Medical Kit System. This reassessment led to the system being streamlined to meet future logistical considerations with current Russian space vehicles and future NASA/commercial space vehicle systems. Methods The JSC Space Medicine Division coordinated the development of requirements, fabrication of prototypes, and conducted usability testing for the new ISS Medical Kit System in concert with implementing updated versions of the ISS Medical Check List and associated in-flight software applications. The teams constructed a medical kit system with the flexibility for use on the ISS, and resupply on the Russian Progress space vehicle and future NASA/commercial space vehicles. Results Prototype systems were developed, reviewed, and tested for implementation. Completion of Preliminary and Critical Design Reviews resulted in a streamlined ISS Medical Kit System that is being used for training by ISS crews starting with Expedition 27 (June 2011). Conclusions The team will present the process for designing, developing, , implementing, and training with this new ISS Medical Kit System.
International Cursor on Target (CoT) User Group Meeting (1st), 2-3 April 2013
2013-07-01
0900 - 0930 BREAK 0930 - 0945 ATAK ( Android Tactical Assault Kit) Josh Sterling 0945 - 1045 Use of CoT in Military Operations Luke Savoie...satisfaction = 4; Food services = 5 Definitely poll for requirements requests ahead of time. Better multimedia system setup (though you did have a...really cool setup and multimedia thing!) Give a list of attendees to all so I can network. CoT and BAO Kit. Field incompatibility between CoT and
Marsan, David W; Conrad, Stephen M; Stutts, Whitney L; Parker, Christine H; Deeds, Jonathan R
2018-03-01
The cyanobacterium Aphanizomenon flos-aquae (AFA), from Upper-Klamath Lake, Oregon, are used to produce blue-green algal (BGA) dietary supplements. The periodic co-occurrence of hepatotoxin-producing contaminant species prompted the Oregon Health Division to establish a limit of 1 μg/g microcystin (MC) for products sold in Oregon in 1997. At the federal level, the current good manufacturing practice (CGMP) regulations for dietary supplements require manufacturers establish a specification, and test, for limits on contaminants that may adulterate finished products. Despite this, several previous international surveys reported MC in BGA supplements in excess of 1 μg/g. The objectives of this study were (1) identify a reliable, easy to use test kit for the detection of MC in dried BGA materials and (2) use this kit to assess the occurrence of MC contamination in AFA-BGA dietary supplements in the U.S. A commercial protein phosphatase inhibition assay (PPIA), based on the enzyme PP2A, was found to have acceptable relative enzyme inhibition and accuracy for the majority of MC variants tested, including those most commonly identified in commercial samples, making the kit fit for purpose. Using the PPIA kit, 51% (26 of 51) distinct AFA-BGA products had MC ≥0.25 μg/g (the detection limit of the kit), 10 products had MC concentrations between 0.5 and 1.0 μg/g, and 4 products exceeded the limit (1.1-2.8 μg/g). LC-MS/MS confirmed PPIA results ≥0.5 μg/g and determined that MC-LA and MC-LR were the main congeners present. PPIA is a reliable method for the detection of MC contamination in dried BGA dietary supplements produced in the U.S. While the majority of AFA-BGA products contained ≥0.25 μg/g MC, most were at or below 1.0 μg/g, suggesting that manufacturers have adopted this level as a specification in these products; however, variability in recommended serving sizes prevented further analysis of consumer exposure based on the concentrations of MC contamination found.
1998-10-01
Stay Breast Cancer Surgery Self -Test Kit: Rapid Diagnosis of Urogenital Infections in Military Women PRINCIPAL INVESTIGATOR: Gwen K. Wyatt, R.N...the home and phone contacts) consisting of individual physical and psychological support, self -care, and education; and the control group, who receive...intervention and control group perceptions on the dimensions of physical functioning, anxiety status, quality of life, and self -care knowledge. C. Compare the
ERIC Educational Resources Information Center
Hausman, Ralph M.; Apffel, James A.
The differential effects of the final revision of Levels 1 and 2 of the Peabody Language Development Kits (PLDK) on the Illinois Test of Psycholinguistic Abilities (ITPA) profiles of young disadvantaged black children were studied. Contrasted with 90 control subjects were 90 experimental subjects who received a daily 30-minute oral language…
Mohammadpour, Niloofar; Saki, Jasem; Rafiei, Abdollah; Khodadadi, Ali; Tavalla, Mehdi; Cheraghian, Bahman
2016-10-01
Toxoplasma gondii is one of the most common causes of latent infections in humans worldwide. Detecting anti- Toxoplasma antibodies in serum using serological tests is a common method to diagnose toxoplasmosis. In the present study, an indigenous ELISA kit was prepared using tachyzoites from the RH strain of T. gondii , and its sensitivity and specificity were compared with those of commercial kits. To produce antigens, 0.02 mL of locally isolated T. gondii RH strain parasites along with 10 9 tachyzoites were injected into the peritoneal cavities of 50 laboratory mice (BALB/C). Parasites were collected after 4 days. After filtering and washing, the concentration of protein in sonicated tachyzoites was calculated using the Lowry protein assay. The dilution of antigen, serum and alkaline phosphatase conjugate was assessed in designing an indigenous ELISA method; then ELISA was performed based on these dilutions, and its sensitivity was determined using 200 serum samples. In addition, the specificity of the assay was evaluated using 40 serum samples from patients with tuberculosis, leukemia or hydatid cyst. Indigenous ELISA was used to examine 100 serum samples containing anti- T. gondii IgG, with a sensitivity of 98% (commercial kits: 100%). Another 100 serum samples containing anti- T. gondii IgM were also tested, with a sensitivity of 99% (commercial kits: 100%). When 40 serum samples from patients with leukemia, hydatid cyst or tuberculosis were examined using anti- T. gondii IgG, the specificity was 100%, identical to commercial kits. However, the specificity of a similar test with anti- T. gondii IgM was just 28.6% for serum samples from leukemia patients, 21.4% for hydatid cyst and 16.7% for tuberculosis. We found that purified locally isolated soluble crude antigens of the RH strain of T. gondii from the peritoneal cavity of mice may be one of the most promising antigens for detection of human toxoplasmosis in routine screening.
Woodhall, Sarah C; Nichols, Tom; Alexander, Sarah; da Silva, Filomeno Coelho; Mercer, Catherine H; Ison, Catherine; Gill, O Noel; Soldan, Kate
2015-09-01
Chlamydia prevalence in the general population is a potential outcome measure for the evaluation of chlamydia control programmes. We carried out a pilot study to determine the feasibility of using a postal survey for population-based chlamydia prevalence monitoring. Postal invitations were sent to a random sample of 2000 17-year-old to 18-year-old women registered with a general practitioner in two pilot areas in England. Recipients were randomised to receive either a self-sampling kit (n=1000), a self-sampling kit and offer of £5 voucher on return of sample (n=500) or a self-sampling kit on request (n=500). Participants returned a questionnaire and self-taken vulvovaginal swab sample for unlinked anonymous Chlamydia trachomatis testing. Non-responders were sent a reminder letter 3 weeks after initial invitation. We calculated the participation rate (number of samples returned/number of invitations sent) and cost per sample returned (including cost of consumables and postage) in each group. A total of 155/2000 (7.8%) samples were returned with consent for testing. Participation rates varied by invitation group: 7.8% in the group who were provided with a self-sampling kit, 14% in the group who were also offered a voucher and 1.0% in the group who were not sent a kit. The cost per sample received was lowest (£36) in the group who were offered both a kit and a voucher. The piloted survey methodology achieved low participation rates. This approach is not suitable for population-based monitoring of chlamydia prevalence among young women in England. (UKCRN ID 10913). Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Feasibility and acceptability of HIV self-testing among pre-exposure prophylaxis users in Kenya.
Ngure, Kenneth; Heffron, Renee; Mugo, Nelly; Thomson, Kerry A; Irungu, Elizabeth; Njuguna, Njambi; Mwaniki, Lawrence; Celum, Connie; Baeten, Jared M
2017-02-10
HIV testing is key to the delivery of pre-exposure prophylaxis (PrEP): testing HIV-uninfected at-risk persons is the first step for PrEP initiation and ongoing HIV testing is an essential part of PrEP delivery. Thus, novel and cost-effective HIV-testing approaches to streamline delivery of PrEP are urgently needed. Within a demonstration project of PrEP for HIV prevention among high-risk HIV serodiscordant couples in Kenya (the Partners Demonstration Project), we conducted a pilot evaluation of HIV self-testing. Clinic visits were scheduled quarterly and included in-clinic HIV testing using fingerstick rapid HIV tests and refills of PrEP prescriptions. HIV oral fluid self-test kits were provided for participants to use in the two-month interval between scheduled quarterly clinic visits. Acceptability of HIV self-testing was assessed using both quantitative and qualitative methods. We found that 222 of 226 (98%) HIV-uninfected persons who were offered accepted self-testing. Nearly all (96.8%) reported that using the self-testing kit was easy. More than half (54.5%) reportedly did not share the HIV results from self-testing with anyone and almost all (98.7%) the participants did not share the HIV self-testing kits with anyone. Many participants reported that HIV self-testing was empowering and reduced anxiety associated with waiting between clinic HIV tests. HIV self-testing was highly acceptable and may therefore be a feasible strategy to efficiently permit routine HIV testing between PrEP refills.
In July 1997, the U.S. Environmental Protection Agency (EPA) conducted a demonstration of polychlorinated biphenyl (PCB) field analytical techniques. The purpose of this demonstration was to evaluate field analytical technologies capable of detecting and quantifying PCB's in soi...
NASA Astrophysics Data System (ADS)
Rice, Tony E.
The purpose of this survey was to describe and analyze the perceptions of elementary school teachers' in a Midwestern state concerning their use of a science kit program, including to what extent a school's state science assessment scores can be predicated from the level of science kit usage. Prior research indicates that elementary school teachers lack the confidence in teaching science primarily because of their weak undergraduate training in inquiry-based instruction and the lack of a strong science background. Authors such as Dickerson et al. (2006) and Riggs and Enochs (2006) argued that science kits and the materials included in them are valuable in increasing teacher confidence. The teacher perceptions I collected matched the literature quite closely as far as what the teachers found to be of the most value and use. Teachers perceptions of the science kits were positive including: (a) student engagement in using the science kits, (b) use of most of the instructional items included in the kits, (c) the amount of teacher confidence in using them, (d) the support from the math and science center for using them, (e) and the professional development provided. Teachers liked using many components of the kits, especially the experiments. Their main complaint concerned time: time to teach science and time to complete the kit lessons. I used multiple regression to understand the components of the kit program that had a significant correlation to the state test scores. The following variables could explain a high proportion of the variance (.796): (a) teacher confidence, (b) student science learning success, (c) teacher beliefs about science education and (d) the percentage of students eligible for the National School Lunch Program. These findings might lead to school principals and teachers increasing their 5th grade state science exam scores by using the findings to identify which components of the kit program are most important in this endeavor.
Towards intelligent diagnostic system employing integration of mathematical and engineering model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Isa, Nor Ashidi Mat
The development of medical diagnostic system has been one of the main research fields during years. The goal of the medical diagnostic system is to place a nosological system that could ease the diagnostic evaluation normally performed by scientists and doctors. Efficient diagnostic evaluation is essentials and requires broad knowledge in order to improve conventional diagnostic system. Several approaches on developing the medical diagnostic system have been designed and tested since the earliest 60s. Attempts on improving their performance have been made which utilizes the fields of artificial intelligence, statistical analyses, mathematical model and engineering theories. With the availability ofmore » the microcomputer and software development as well as the promising aforementioned fields, medical diagnostic prototypes could be developed. In general, the medical diagnostic system consists of several stages, namely the 1) data acquisition, 2) feature extraction, 3) feature selection, and 4) classifications stages. Data acquisition stage plays an important role in converting the inputs measured from the real world physical conditions to the digital numeric values that can be manipulated by the computer system. One of the common medical inputs could be medical microscopic images, radiographic images, magnetic resonance image (MRI) as well as medical signals such as electrocardiogram (ECG) and electroencephalogram (EEG). Normally, the scientist or doctors have to deal with myriad of data and redundant to be processed. In order to reduce the complexity of the diagnosis process, only the significant features of the raw data such as peak value of the ECG signal or size of lesion in the mammogram images will be extracted and considered in the subsequent stages. Mathematical models and statistical analyses will be performed to select the most significant features to be classified. The statistical analyses such as principal component analysis and discriminant analysis as well as mathematical model of clustering technique have been widely used in developing the medical diagnostic systems. The selected features will be classified using mathematical models that embedded engineering theory such as artificial intelligence, support vector machine, neural network and fuzzy-neuro system. These classifiers will provide the diagnostic results without human intervention. Among many publishable researches, several prototypes have been developed namely NeuralPap, Neural Mammo, and Cervix Kit. The former system (NeuralPap) is an automatic intelligent diagnostic system for classifying and distinguishing between the normal and cervical cancerous cells. Meanwhile, the Cervix Kit is a portable Field-programmable gate array (FPGA)-based cervical diagnostic kit that could automatically diagnose the cancerous cell based on the images obtained during sampling test. Besides the cervical diagnostic system, the Neural Mammo system is developed to specifically aid the diagnosis of breast cancer using a fine needle aspiration image.« less
Towards intelligent diagnostic system employing integration of mathematical and engineering model
NASA Astrophysics Data System (ADS)
Isa, Nor Ashidi Mat
2015-05-01
The development of medical diagnostic system has been one of the main research fields during years. The goal of the medical diagnostic system is to place a nosological system that could ease the diagnostic evaluation normally performed by scientists and doctors. Efficient diagnostic evaluation is essentials and requires broad knowledge in order to improve conventional diagnostic system. Several approaches on developing the medical diagnostic system have been designed and tested since the earliest 60s. Attempts on improving their performance have been made which utilizes the fields of artificial intelligence, statistical analyses, mathematical model and engineering theories. With the availability of the microcomputer and software development as well as the promising aforementioned fields, medical diagnostic prototypes could be developed. In general, the medical diagnostic system consists of several stages, namely the 1) data acquisition, 2) feature extraction, 3) feature selection, and 4) classifications stages. Data acquisition stage plays an important role in converting the inputs measured from the real world physical conditions to the digital numeric values that can be manipulated by the computer system. One of the common medical inputs could be medical microscopic images, radiographic images, magnetic resonance image (MRI) as well as medical signals such as electrocardiogram (ECG) and electroencephalogram (EEG). Normally, the scientist or doctors have to deal with myriad of data and redundant to be processed. In order to reduce the complexity of the diagnosis process, only the significant features of the raw data such as peak value of the ECG signal or size of lesion in the mammogram images will be extracted and considered in the subsequent stages. Mathematical models and statistical analyses will be performed to select the most significant features to be classified. The statistical analyses such as principal component analysis and discriminant analysis as well as mathematical model of clustering technique have been widely used in developing the medical diagnostic systems. The selected features will be classified using mathematical models that embedded engineering theory such as artificial intelligence, support vector machine, neural network and fuzzy-neuro system. These classifiers will provide the diagnostic results without human intervention. Among many publishable researches, several prototypes have been developed namely NeuralPap, Neural Mammo, and Cervix Kit. The former system (NeuralPap) is an automatic intelligent diagnostic system for classifying and distinguishing between the normal and cervical cancerous cells. Meanwhile, the Cervix Kit is a portable Field-programmable gate array (FPGA)-based cervical diagnostic kit that could automatically diagnose the cancerous cell based on the images obtained during sampling test. Besides the cervical diagnostic system, the Neural Mammo system is developed to specifically aid the diagnosis of breast cancer using a fine needle aspiration image.
Dayton, Melody; Koskinen, Mikko T; Tom, Bradley K; Mattila, Anna-Maria; Johnston, Eric; Halverson, Joy; Fantin, Dennis; DeNise, Sue; Budowle, Bruce; Smith, David Glenn; Kanthaswamy, Sree
2009-01-01
Aim To develop a reagent kit that enables multiplex polymerase chain reaction (PCR) amplification of 18 short tandem repeats (STR) and the canine sex-determining Zinc Finger marker. Methods Validation studies to determine the robustness and reliability in forensic DNA typing of this multiplex assay included sensitivity testing, reproducibility studies, intra- and inter-locus color balance studies, annealing temperature and cycle number studies, peak height ratio determination, characterization of artifacts such as stutter percentages and dye blobs, mixture analyses, species-specificity, case type samples analyses and population studies. Results The kit robustly amplified domesticated dog samples and consistently generated full 19-locus profiles from as little as 125 pg of dog DNA. In addition, wolf DNA samples could be analyzed with the kit. Conclusion The kit, which produces robust, reliable, and reproducible results, will be made available for the forensic research community after modifications based on this study’s evaluation to comply with the quality standards expected for forensic casework. PMID:19480022
Assessment of DNA extracted from FTA® cards for use on the Illumina iSelect BeadChip
McClure, Matthew C; McKay, Stephanie D; Schnabel, Robert D; Taylor, Jeremy F
2009-01-01
Background As FTA® cards provide an ideal medium for the field collection of DNA we sought to assess the quality of genomic DNA extracted from this source for use on the Illumina BovineSNP50 iSelect BeadChip which requires unbound, relatively intact (fragment sizes ≥ 2 kb), and high-quality DNA. Bovine blood and nasal swab samples collected on FTA cards were extracted using the commercially available GenSolve kit with a minor modification. The call rate and concordance of genotypes from each sample were compared to those obtained from whole blood samples extracted by standard PCI extraction. Findings An ANOVA analysis indicated no significant difference (P > 0.72) in BovineSNP50 genotype call rate between DNA extracted from FTA cards by the GenSolve kit or extracted from whole blood by PCI. Two sample t-tests demonstrated that the DNA extracted from the FTA cards produced genotype call and concordance rates that were not different to those produced by assaying DNA samples extracted by PCI from whole blood. Conclusion We conclude that DNA extracted from FTA cards by the GenSolve kit is of sufficiently high quality to produce results comparable to those obtained from DNA extracted from whole blood when assayed by the Illumina iSelect technology. Additionally, we validate the use of nasal swabs as an alternative to venous blood or buccal samples from animal subjects for reliably producing high quality genotypes on this platform. PMID:19531223
Assessment of DNA extracted from FTA cards for use on the Illumina iSelect BeadChip.
McClure, Matthew C; McKay, Stephanie D; Schnabel, Robert D; Taylor, Jeremy F
2009-06-16
As FTA cards provide an ideal medium for the field collection of DNA we sought to assess the quality of genomic DNA extracted from this source for use on the Illumina BovineSNP50 iSelect BeadChip which requires unbound, relatively intact (fragment sizes >or= 2 kb), and high-quality DNA. Bovine blood and nasal swab samples collected on FTA cards were extracted using the commercially available GenSolve kit with a minor modification. The call rate and concordance of genotypes from each sample were compared to those obtained from whole blood samples extracted by standard PCI extraction. An ANOVA analysis indicated no significant difference (P > 0.72) in BovineSNP50 genotype call rate between DNA extracted from FTA cards by the GenSolve kit or extracted from whole blood by PCI. Two sample t-tests demonstrated that the DNA extracted from the FTA cards produced genotype call and concordance rates that were not different to those produced by assaying DNA samples extracted by PCI from whole blood. We conclude that DNA extracted from FTA cards by the GenSolve kit is of sufficiently high quality to produce results comparable to those obtained from DNA extracted from whole blood when assayed by the Illumina iSelect technology. Additionally, we validate the use of nasal swabs as an alternative to venous blood or buccal samples from animal subjects for reliably producing high quality genotypes on this platform.
Peng, Yunping; Wu, Junlin; Wang, Jihua; Li, Wenmei; Yu, Shujuan
2012-04-01
Malaria has been recognized as a human disease for thousands of years and remains one of the most common diseases affecting humans worldwide. Therefore, a method for rapidly detecting Plasmodium falciparum is necessary and useful. We have developed Wondfo rapid diagnostic kit based on nano-gold immunochromatography assay for the detection of P. falciparum in patient specimen. In the present study, we demonstrated the sensitivity and specificity of the rapid diagnostic kit in which nano-gold labeling techniques and the monoclonal antibodies against histidine-rich protein-2 of P. falciparum were used to establish two-antibody sandwich immunochromatographic assay for detecting P. falciparum. By using microscopic examination of blood smears as control, the sensitivity, specificity, and feasibility of Wondfo rapid diagnostic kit was determined in the prompt and accurate diagnosis of malaria. In this study, 1,558 blood samples were collected from outpatient clinics in China and detected by both Wondfo kit and microscopic examination. The Wondfo kit did not show cross-reaction with microfilaria, Toxoplasma gondii, and other parasites in the blood. The patient samples positive for rheumatoid factor, HIV, tuberculosis, and syphilis did not show false positivity when testing with Wondfo kit. The detection sensitivity and specificity of Wondfo rapid diagnostic kit were 95.49% and 99.53%, respectively. These results indicate that our rapid diagnostic assay may be useful for detecting P. falciparum in patient specimen.
Chen, Hsiao Ying; Tran, Hung; Foo, Ling Yann; Sew, Tracey Wenhui; Loke, Weng Keong
2014-08-01
Ricin is a toxin that can be easily extracted from seeds of Ricinus communis plants. Ricin is considered to be a major bio-threat as it can be freely and easily acquired in large quantities. A deliberate release of such toxin in civilian populations would very likely overwhelm existing public health systems, resulting in public fear and social unrest. There is currently no commercially available or FDA-approved prophylaxis such as vaccines, or therapeutic antitoxins or antidotes, available for ricin intoxication. Patient treatment is typically supportive care based on symptoms, often designed to reinforce the body's natural response. This paper describes the development and validation of a robust ELISA test kit, which can be used to screen for ricin in biological specimens such as whole blood and faeces. Faecal specimens are shown in this study to have better diagnostic sensitivity and a wider diagnostic window compared to whole blood. From these results, it is concluded that faeces is the most suitable clinical specimen for diagnosis of ricin poisoning via the oral route. The ELISA test kit can also detect ricin in environmental samples. An advantage of this ELISA kit over other commercial off-the-shelf (COTS) detection kits currently on the market that are developed to screen environmental samples only is its ability to diagnose ricin poisoning from clinical specimens as well as detect ricin from environmental samples.
Zhou, Jie; Liao, Yu-xue; Chen, Zhong; Li, Yu-chun; Gao, Lu-Lu; Chen, Yi-xiong; Cai, Lian-gong; Chen, Qing; Yu, Shou-yi
2008-05-01
To develop an simple and sensitive method for detecting anti-coronavirus IgG antibodies in bat sera based on enzyme-linked immunosorbent assay (ELISA). A commercial ELISA kit for detecting SARS-CoV antibody was modified for detecting coronavirus antibodies in bat serum samples. The second antibody in the kit was replaced with horseradish peroxidase-conjugated protein-A (HRP-SPA) based on the characteristics of binding between Staphylococcus aureus protein A (SPA) and mammal IgG Fc fragment. The sera of 55 fulvous fruit bats (Rousettus dasymallus) were tested using the SPA-ELISA. The test results of the positive and negative controls in the kit and the serum samples from convalescent ;patient were consistent with expectation. Coronavirus antibody was detected in 2 out of the 55 bat serum samples. Serum neutralization test confirmed the validity of the SPA-ELISA method. This SPA-ELISA method is applicable for detecting coronavirus antibody in bat sera.
Starkova, T V; Poletaeva, O G; Kovrova, E A; Krasovskaia, N N; Tkachenko, T N; Masiago, A V; Ofitserov, V I; Tereshchenko, A Iu
2011-01-01
The efficacy of a kit of Opisthorchiasis-CIC-EIA-Best reagents was evaluated using 270 sera from patients in the study and control groups. The kit showed a sufficient sensitivity (not less than 87.2%) and a high specificity (not less than 97.9%). The use of the above kit of the reagents for enzyme immunoassay in practical healthcare enables one to increase detection rates among the infested subjects on comprehensive examination of those with suspected opisthorchiasis.
The Classroom-Friendly ABO Blood Types Kit: Blood Agglutination Simulation
ERIC Educational Resources Information Center
Arnold, Savittree Rochanasmita; Kruatong, Tussatrin; Dahsah, Chanyah; Suwanjinda, Duongdearn
2012-01-01
The classroom-friendly ABO blood type kit was developed by combining advantages of modelling and a simulation laboratory to teach the topics of ABO blood types and blood transfusion. Teachers can easily simulate the agglutination reaction on a blood type testing plate in the classroom, and show the students how this reaction occurs by using the…
ERIC Educational Resources Information Center
Downey, Carolyn J.; Steffy, Betty E.; English, Fenwick W.; Frase, Larry E.; Poston, William K.
2006-01-01
Showcasing the "Downey Walk-Through"--a method developed over a 40-year period, tested and refined in real-world schools and classrooms, and described in the pioneering book, "The Three-Minute Classroom Walk-Through," this innovative multimedia presentation provides trainers and staff developers with a complete resource answering the questions…
Dries, Jan; Daens, Dominique; Geuens, Luc; Blust, Ronny
2014-01-01
The present study compares conventional wastewater treatment technologies (coagulation-flocculation and activated sludge) and powdered activated carbon (PAC) treatment for the removal of acute ecotoxicity from wastewater generated by tank truck cleaning (TTC) processes. Ecotoxicity was assessed with a battery of four commercially available rapid biological toxicity testing systems, verified by the US Environmental Protection Agency. Chemical coagulation-flocculation of raw TTC wastewater had no impact on the inhibition of the bioluminescence by Vibrio fischeri (BioTox assay). Subsequent biological treatment with activated sludge without PAC resulted in BioTox inhibition-free effluent (<10% inhibition). In contrast, activated sludge treatment without PAC produced an effluent that significantly inhibited (>50%) (i) the bioluminescence by Photobacterium leiognathi (ToxScreen³ test kit), (ii) the photosynthesis by the green algae Chlorella vulgaris (LuminoTox SAPS test kit), and (iii) the particle ingestion by the crustacean Thamnocephalus platyurus (Rapidtoxkit test kit). The lowest inhibition was measured after activated sludge treatment with the highest PAC dose (400 mg/L), demonstrating the effectiveness of PAC treatment for ecotoxicity removal from TTC wastewater. In conclusion, the combination of bioassays applied in the present study represents a promising test battery for rapid ecotoxicty assessment in wastewater treatment.
Hannon, Peggy A; Vu, Thuy; Ogdon, Sara; Fleury, Emily M; Yette, Emily; Wittenberg, Reva; Celedonia, Megan; Bowen, Deborah J
2013-03-01
Colorectal cancer screening is a life-saving intervention, but screening rates are low. The authors implemented and evaluated the Spokane Colorectal Cancer Screening Program-a novel worksite intervention to promote colorectal cancer screening that used a combination of evidence-based strategies recommended by the Guide to Community Preventive Services, as well as additional strategies. Over a period of approximately 3 months, participating worksites held one or more physician-led seminars about colorectal cancer screening for employees. They also distributed free fecal immunochemical tests at the worksite to employees 50 years and older, and they provided test results to employees and their primary care physician. The authors measured attendance at seminars, test kits taken and returned, employee awareness of the program, and colorectal cancer screening rates in participating and comparison worksites. It is estimated that 9% of eligible employees received kits at the worksite, and 4% were screened with these kits. The Spokane Colorectal Cancer Screening Program was a promising pilot test of an innovative worksite screening program that successfully translated evidence-based strategies into practical use in a brief period of time, and it merits a larger study to be able to test its effects more rigorously.
Junge, Benjamin; Berghof-Jäger, Kornelia
2006-01-01
A method was developed for the detection of L. monocytogenes in food based on real-time polymerase chain reaction (PCR). This advanced PCR method was designed to reduce the time needed to achieve results from PCR reactions and to enable the user to monitor the amplification of the PCR product simultaneously, in real-time. After DNA isolation using the Roche/BIOTECON Diagnostics ShortPrep foodproof II Kit (formerly called Listeria ShortPrep Kit) designed for the rapid preparation of L. monocytogenes DNA for direct use in PCR, the real-time detection of L. monocytogenes DNA is performed by using the Roche/BIOTECON Diagnostics LightCycler foodproof L. monocytogenes Detection Kit. This kit provides primers and hybridization probes for sequence-specific detection, convenient premixed reagents, and different controls for reliable interpretation of results. For repeatability studies, 20 different foods, covering the 15 food groups recommended from the AOAC Research Institute (AOAC RI) for L. monocytogenes detection were analyzed: raw meats, fresh produce/vegetables, processed meats, seafood, egg and egg products, dairy (cultured/noncultured), spices, dry foods, fruit/juices, uncooked pasta, nuts, confectionery, pet food, food dyes and colorings, and miscellaneous. From each food 20, samples were inoculated with a low level (1-10 colony-forming units (CFU)/25 g) and 20 samples with a high level (10-50 CFU/25 g) of L. monocytogenes. Additionally, 5 uninoculated samples were prepared from each food. The food samples were examined with the test kits and in correlation with the cultural methods according to U.S. Food and Drug Administration (FDA) Bacteriological Analytical Manual (BAM) or U.S. Department of Agriculture (USDA)/Food Safety and Inspection Service (FSIS) Microbiology Laboratory Guidebook. After 48 h of incubation, the PCR method in all cases showed equal or better results than the reference cultural FDA/BAM or USDA/FSIS methods. Fifteen out of 20 tested food types gave exactly the same amount of positive samples for both methods in both inoculation levels. For 5 out of 20 foodstuffs, the PCR method resulted in more positives than the reference method after 48 h of incubation. Following AOAC RI definition, these were false positives because they were not confirmed by the reference method (false-positive rate for low inoculated foodstuffs: 5.4%; for high inoculated foodstuffs: 7.1%). Without calculating these unconfirmed positives, the PCR method showed equal sensitivity results compared to the alternative method. With the unconfirmed PCR-positives included into the calculations, the alternative PCR method showed a higher sensitivity than the microbiological methods (low inoculation level: 100 vs 98.0%; sensitivity rate: 1; high inoculation level: 99.7 vs 97.7%; sensitivity rate, 1). All in-house and independently tested uninoculated food samples were negative for L. monocytogenes. The ruggedness testing of both ShortPrep foodproof II Kit and Roche/BIOTECON LightCycler foodproof L. monocytogenes Detection Kit showed no noteworthy influences to any variation of the parameters component concentration, apparatus comparison, tester comparison, and sample volumes. In total, 102 L. monocytogenes isolates (cultures and pure DNA) were tested and detected for the inclusivity study, including all isolates claimed by the AOAC RI. The exclusivity study included 60 non-L. monocytogenes bacteria. None of the tested isolates gave a false-positive result; specificity was 100%. Three different lots were tested in the lot-to-lot study. All 3 lots gave equal results. The stability study was subdivided into 3 parts: long-term study, stress test, and freeze-defrost test. Three lots were tested in 4 time intervals within a period of 13 months. They all gave comparable results for all test intervals. For the stress test, LightCycler L. monocytogenes detection mixes were stored at different temperatures and tested at different time points during 1 month. Stable results were produced at all storage temperatures. The freeze-defrost analysis showed no noteworthy aggravation of test results. The independent validation study examined by Campden and Chorleywood Food Research Association Group (CCFRA) demonstrated again that the LightCycler L. monocytogenes detection system shows a comparable sensitivity to reference methods. With both the LightCycler PCR and BAM methods, 19 out of 20 inoculated food samples were detected. The 24 h PCR results generated by the LightCycler system corresponded directly with the FDA/BAM culture results. However, the 48 h PCR results did not relate exactly to the FDA/BAM results, as one sample found to be positive by the 48 h PCR could not be culturally confirmed and another sample which was negative by the 48 h PCR was culturally positive.
Performance of rapid test kits to assess household coverage of iodized salt.
Gorstein, Jonathan; van der Haar, Frits; Codling, Karen; Houston, Robin; Knowles, Jacky; Timmer, Arnold
2016-10-01
The main indicator adopted to track universal salt iodization has been the coverage of adequately iodized salt in households. Rapid test kits (RTK) have been included in household surveys to test the iodine content in salt. However, laboratory studies of their performance have concluded that RTK are reliable only to distinguish between the presence and absence of iodine in salt, but not to determine whether salt is adequately iodized. The aim of the current paper was to examine the performance of RTK under field conditions and to recommend their most appropriate use in household surveys. Standard performance characteristics of the ability of RTK to detect the iodine content in salt at 0 mg/kg (salt with no iodine), 5 mg/kg (salt with any added iodine) and 15 mg/kg ('adequately' iodized salt) were calculated. Our analysis employed the agreement rate (AR) as a preferred metric of RTK performance. Setting/Subjects Twenty-five data sets from eighteen population surveys which assessed household iodized salt by both the RTK and a quantitative method (i.e. titration or WYD Checker) were obtained from Asian (nineteen data sets), African (five) and European (one) countries. In detecting iodine in salt at 0 mg/kg, the RTK had an AR>90 % in eight of twenty-three surveys, while eight surveys had an AR90 %. The RTK is not suited for assessment of adequately iodized salt coverage. Quantitative assessment, such as by titration or WYD Checker, is necessary for estimates of adequately iodized salt coverage.
Freeman, Karoline; Connock, Martin; Auguste, Peter; Taylor-Phillips, Sian; Mistry, Hema; Shyangdan, Deepson; Court, Rachel; Arasaradnam, Ramesh; Sutcliffe, Paul; Clarke, Aileen
2016-11-01
Systematic reviews and economic modelling of clinical effectiveness and cost-effectiveness of therapeutic monitoring of tumour necrosis factor alpha (TNF-α) inhibitors [using LISA-TRACKER ® enzyme-linked immunosorbent assay (ELISA) kits (Theradiag, Marne La Vallee, France, or Alpha Laboratories, Heriot, UK), TNF-α-Blocker ELISA kits (Immundiagnostik AG, Bensheim, Germany) and Promonitor ® ELISA kits (Proteomika, Progenika Biopharma, Bizkaia, Spain)] versus standard care for Crohn's disease (CD). Multiple electronic databases were searched from inception to December 2014 in order to identify primary studies and meta-analyses. Patients with moderate to severe active CD treated with infliximab (IFX) (Remicade ® , Merck Sharp & Dohme Ltd, Kenilworth, NJ, USA) or adalimumab (ADA) (Humira ® , AbbVie Inc., North Chicago, IL, USA). Monitoring of serum anti-TNF-α (IFX or ADA) and/or of anti-drug antibody levels using test assays with a test-treatment algorithm. Standard care. Any patient-related outcome, test agreement and cost-effectiveness estimates. The quality assessments used recognised checklists (Quality Assessment of Diagnostic Accuracy Studies-2, Cochrane, Philips and Consolidated Health Economic Evaluation Reporting Standards). Evidence was synthesised using narrative review and meta-analysis. A Markov model was built in TreeAge Pro 2013 (TreeAge Software, Inc., Williamstown, MA, USA). The model had a 4-week cycle and a 10-year time horizon, adopted a NHS and Personal Social Services perspective and used a linked evidence approach. Costs were adjusted to 2013/14 prices and discounted at 3.5%. We included 68 out of 2434 and 4 out of 2466 studies for the clinical effectiveness and cost-effectiveness reviews, respectively. Twenty-three studies comparing test methods were identified. Evidence on test concordance was sparse and contradictory, offering scant data for a linked evidence approach. Three studies [two randomised controlled trials (RCTs) and one retrospective observational study] investigated outcomes following implementation of a test algorithm. None used the specified commercial ELISA immunoassay test kits. Neither of the two RCTs demonstrated clinical benefit of a test-treatment regimen. A meta-analysis of 31 studies to estimate test accuracy for predicting clinical status indicated that 20-30% of test results are likely to be inaccurate. The four cost-effectiveness studies suggested that testing results in small cost reductions. In the economic analysis the base-case analysis showed that standard practice (no testing/therapeutic monitoring with the intervention tests) was more costly and more effective than testing for IFX. Sensitivity and scenario analyses gave similar results. The probabilistic sensitivity analysis indicated a 92% likelihood that the 'no-testing' strategy was cost-effective at a willingness to pay of £20,000 per quality-adjusted life-year. Rigorous systematic reviews were undertaken; however, the underlying evidence base was poor or lacking. There was uncertainty about a linked evidence approach and a lack of gold standard for assay comparison. The only comparative evidence available for economic evaluation was for assays other than the intervention assays. Our finding that testing is not cost-effective for IFX should be viewed cautiously in view of the limited evidence. Clinicians should be mindful of variation in performance of different assays and of the absence of standardised approaches to patient assessment and treatment algorithms. There is substantial variation in the underlying treatment pathways and uncertainty in the relative effectiveness of assay- and test-based treatment algorithms, which requires further investigation. There is very little research evidence on ADA or on drug monitoring in children with CD, and conclusions on cost-effectiveness could not be reached for these. This study is registered as PROSPERO CRD42014015278. The National Institute for Health Research Health Technology Assessment programme.
NASA Astrophysics Data System (ADS)
Li, Lu; Zhou, Pin; Zhang, Hongbo; Meng, Xianglong; Li, Juexiu; Sun, Tonghua
2017-06-01
Rare earth oxides (RE = Ce, La, Sm and Gd) doped ZnO supported on KIT-6 sorbents (RE-ZnO/KIT-6) were synthesized by sol-gel method and their performance for deep removal of H2S (bellow 0.1 ppmv) from gas stream at medium temperature was tested. The RE dopants (except Ce) significantly enhance the deep desulfurization capacity of ZnO/KIT-6 sorbent and maintained higher sulfur uptake capacities upon multiple cycles of regeneration by a simple thermal oxidation in 10 v% of O2 in N2 atmosphere. The results of SAXS, XRD, N2 physisorption, TEM, FIIR, and XPS implied that the KIT-6 structure of loading metal oxides remained intact. It was found that RE could hinder the ZnO crystal ripening during calcination resulted in smaller ZnO particles, enhance the interaction of ZnO and silica matrix to improve the dispersion of active phase on KIT-6. Furthermore, by increasing the outlayer electron density of Zn atom and oxygen transfer ability, the synergistic effect considered to be favorable for RE-ZnO/KIT-6 sulfidation. Even though the performance of improving ZnO dispersion was weaker than that of Sm and Gd, La-ZnO/KIT-6 performs the best deep desulfurizers by changing the surface chemical atmosphere for ZnO. Steam in the gas stream inhibited the capture of H2S by ZnO in the sorbents, in the case of La-ZnO/KIT-6, the steam content should control as lower as 5 v% to ensure the desulfurization efficiency and precision.
A Frameshift Mutation in KIT is Associated with White Spotting in the Arabian Camel
Holl, Heather; Isaza, Ramiro; Mohamoud, Yasmin; Ahmed, Ayeda; Almathen, Faisal; Youcef, Cherifi; Gaouar, Semir; Antczak, Douglas F.; Brooks, Samantha
2017-01-01
While the typical Arabian camel is characterized by a single colored coat, there are rare populations with white spotting patterns. White spotting coat patterns are found in virtually all domesticated species, but are rare in wild species. Theories suggest that white spotting is linked to the domestication process, and is occasionally associated with health disorders. Though mutations have been found in a diverse array of species, fewer than 30 genes have been associated with spotting patterns, thus providing a key set of candidate genes for the Arabian camel. We obtained 26 spotted camels and 24 solid controls for candidate gene analysis. One spotted and eight solid camels were whole genome sequenced as part of a separate project. The spotted camel was heterozygous for a frameshift deletion in KIT (c.1842delG, named KITW1 for White spotting 1), whereas all other camels were wild-type (KIT+/KIT+). No additional mutations unique to the spotted camel were detected in the EDNRB, EDN3, SOX10, KITLG, PDGFRA, MITF, and PAX3 candidate white spotting genes. Sanger sequencing of the study population identified an additional five KITW1/KIT+ spotted camels. The frameshift results in a premature stop codon five amino acids downstream, thus terminating KIT at the tyrosine kinase domain. An additional 13 spotted camels tested KIT+/KIT+, but due to phenotypic differences when compared to the KITW1/KIT+ camels, they likely represent an independent mutation. Our study suggests that there are at least two causes of white spotting in the Arabian camel, the newly described KITW1 allele and an uncharacterized mutation. PMID:28282952
Evaluation of digital PCR for absolute RNA quantification.
Sanders, Rebecca; Mason, Deborah J; Foy, Carole A; Huggett, Jim F
2013-01-01
Gene expression measurements detailing mRNA quantities are widely employed in molecular biology and are increasingly important in diagnostic fields. Reverse transcription (RT), necessary for generating complementary DNA, can be both inefficient and imprecise, but remains a quintessential RNA analysis tool using qPCR. This study developed a Transcriptomic Calibration Material and assessed the RT reaction using digital (d)PCR for RNA measurement. While many studies characterise dPCR capabilities for DNA quantification, less work has been performed investigating similar parameters using RT-dPCR for RNA analysis. RT-dPCR measurement using three, one-step RT-qPCR kits was evaluated using single and multiplex formats when measuring endogenous and synthetic RNAs. The best performing kit was compared to UV quantification and sensitivity and technical reproducibility investigated. Our results demonstrate assay and kit dependent RT-dPCR measurements differed significantly compared to UV quantification. Different values were reported by different kits for each target, despite evaluation of identical samples using the same instrument. RT-dPCR did not display the strong inter-assay agreement previously described when analysing DNA. This study demonstrates that, as with DNA measurement, RT-dPCR is capable of accurate quantification of low copy RNA targets, but the results are both kit and target dependent supporting the need for calibration controls.
Cruz, Cristina D; Win, Jessicah K; Chantarachoti, Jiraporn; Mutukumira, Anthony N; Fletcher, Graham C
2012-02-15
The standard Bacteriological Analytical Manual (BAM) protocol for detecting Listeria in food and on environmental surfaces takes about 96 h. Some studies indicate that rapid methods, which produce results within 48 h, may be as sensitive and accurate as the culture protocol. As they only give presence/absence results, it can be difficult to compare the accuracy of results generated. We used the Most Probable Number (MPN) technique to evaluate the performance and detection limits of six rapid kits for detecting Listeria in seafood and on an environmental surface compared with the standard protocol. Three seafood products and an environmental surface were inoculated with similar known cell concentrations of Listeria and analyzed according to the manufacturers' instructions. The MPN was estimated using the MPN-BAM spreadsheet. For the seafood products no differences were observed among the rapid kits and efficiency was similar to the BAM method. On the environmental surface the BAM protocol had a higher recovery rate (sensitivity) than any of the rapid kits tested. Clearview™, Reveal®, TECRA® and VIDAS® LDUO detected the cells but only at high concentrations (>10(2) CFU/10 cm(2)). Two kits (VIP™ and Petrifilm™) failed to detect 10(4) CFU/10 cm(2). The MPN method was a useful tool for comparing the results generated by these presence/absence test kits. There remains a need to develop a rapid and sensitive method for detecting Listeria in environmental samples that performs as well as the BAM protocol, since none of the rapid tests used in this study achieved a satisfactory result. Copyright © 2011 Elsevier B.V. All rights reserved.
Pros, Eva; Lantuejoul, Sylvie; Sanchez-Verde, Lydia; Castillo, Sandra D; Bonastre, Ester; Suarez-Gauthier, Ana; Conde, Esther; Cigudosa, Juan C; Lopez-Rios, Fernando; Torres-Lanzas, Juan; Castellví, Josep; Ramon y Cajal, Santiago; Brambilla, Elisabeth; Sanchez-Cespedes, Montse
2013-08-15
Growth factor receptors (GFRs) are amenable to therapeutic intervention in cancer and it is important to select patients appropriately. One of the mechanisms for activation of GFRs is gene amplification (GA) but discrepancies arising from the difficulties associated with data interpretation and the lack of agreed parameters confound the comparison of results from different laboratories. Here, we attempt to establish appropriate conditions for standardization of the determination of GA in a panel of GFRs. A NSCLC tissue microarray panel containing 302 samples was screened for alterations at ALK, FGFR1, FGFR2, FGFR3, ERBB2, IGF1R, KIT, MET and PDGFRA by FISH, immunostaining and/or real-time quantitative RT-PCR. Strong amplification was found for FGFR1, ERBB2, KIT/PDFGRA and MET, with frequencies ranging from 1 to 6%. Thresholds for overexpression and GA were established. Strong immunostaining was found in most tumors with ERBB2, MET and KIT amplification, although some tumors underwent strong immunostaining in the absence of GA. KIT and PDFGRA were always coamplified, but only one tumor showed PDGFRA overexpression, indicating that KIT is the main target. Amplification of FGFR1 predominated in squamous cell carcinomas, although the association with overexpression was inconclusive. Interestingly, alterations at ALK, MET, EGFR, ERBB2 and KRAS correlated with augmented levels of phospho-S6 protein, suggesting activation of the mTOR pathway, which may prove useful to pre-select tumors for testing. Overall, here, we provide with parameters for the determination of GA at ERBB2, MET, KIT and PDGFRA which could be implemented in the clinic to stratify lung cancer patients for specific treatments. Copyright © 2013 UICC.
Chernesky, Max; Jang, Dan; Gilchrist, Jodi; Elit, Laurie; Lytwyn, Alice; Smieja, Marek; Dockter, Janel; Getman, Damon; Reid, Jennifer; Hill, Craig
2014-06-01
An APTIMA specimen collection and transportation (SCT) kit was developed by Hologic/Gen-Probe. To compare cervical SCT samples to PreservCyt and SurePath samples and self-collected vaginal samples to physician-collected vaginal and cervical SCT samples. To determine ease and comfort of self-collection with the kit. Each woman (n = 580) self-collected a vaginal SCT, then filled out a questionnaire (n = 563) to determine ease and comfort of self-collection. Colposcopy physicians collected a vaginal SCT and cervical PreservCyt, SCT, and SurePath samples. Samples were tested by APTIMA HPV (AHPV) assay. Agreement between testing of cervical SCT and PreservCyt was 91.1% (κ = 0.82), and that of SurePath samples was 86.7% (κ = 0.72). Agreement of self-collected vaginal SCT to physician-collected SCT was 84.7% (κ = 0.68), and that of self-collected vaginal to cervical SCT was 82.0% (κ = 0.63). For 30 patients with CIN2+, AHPV testing of cervical SCT was 100% sensitive and 59.8% specific compared with PreservCyt (96.6% and 66.2%) and SurePath (93.3% and 70.9%). Vaginal SCT sensitivity was 86.7% for self-collection and 80.0% for physician collection. Most patients found that vaginal self-collection was easy, 5.3% reported some difficulty, and 87.6% expressed no discomfort. Cervical samples collected with the new SCT kit compared well to traditional liquid-based samples tested by AHPV. Although there was good agreement between self-collected and physician-collected samples with the SCT, in a limited number of 30 women, vaginal sampling identified fewer with CIN2+ precancerous cervical lesions than cervical SCT sampling. Comfort, ease of use, and detection of high-risk HPV demonstrated that the kit could be used for cervical and vaginal sampling.
Wallace, F Morgan; DiCosimo, Deana; Farnum, Andrew; Tice, George; Andaloro, Bridget; Davis, Eugene; Burns, Frank R
2011-01-01
In 2010, the BAX System PCR assay for Salmonella was modified to include a hot start functionality designed to keep the reaction enzyme inactive until PCR begins. To validate the assay's Official Methods of Analysis status to include this procedure modification, an evaluation was conducted on four food types that were simultaneously analyzed with the BAX System and either the U.S. Food and Drug Administration's Bacteriological Analytical Manual or the U.S. Department of Agriculture-Food Safety and Inspection Service Microbiology Laboratory Guidebook reference method for detecting Salmonella. Identical performance between the BAX System method and the reference methods was observed. Additionally, lysates were analyzed using both the BAX System Classic and BAX System Q7 instruments with identical results using both platforms for all samples tested. Of the 100 samples analyzed, 34 samples were positive for both the BAX System and reference methods, and 66 samples were negative by both the BAX System and reference methods, demonstrating 100% correlation. No instrument platform variation was observed. Additional inclusivity and exclusivity testing using the modified test kit demonstrated the test kit to be 100% accurate in evaluation of test panels of 352 Salmonella strains and 46 non-Salmonella strains.
Multigen-2 Pre-Flight Testing: Science Testing Unit (STU) and Stowage Conditions
NASA Astrophysics Data System (ADS)
Kittang, A.-I.; Kvaloy, B.; Berg, C.; Rakvaag, G.; Iversen, T.-H.
2008-06-01
The Multigen-2 experiment Science Testing Unit (STU) proved to be a useful tool in optimizing experiment environment settings for cultivation of Arabidopsis thaliana (Col-0) in the European Modular Cultivation System (EMCS). By using the EMCS Experiment Reference Model (ERM); light, temperature and air flow regimes for optimal growth could be tested. Healthy seedlings were obtained using the STU#2 and STU#3 in the EMCS ERM. It was concluded that the Experiment Container Development Kit (ECDK) is unsuitable for the Multigen-2 testing due to limitation in the ECDK temperature control. The results from the stowage condition tests showed that the selected growth medium (agar) can be used after 3 months at +4°C. The seeds show a germination rate of ≥80% after sterilisation and stowed for 5 months. The Multigen-2 plant samples will be fixed in RNA later and stored at - 80 °C. Three methods with different RNA isolation kits showed that the Qiagen kit (#74904) gave the highest amount and the best quality of Total RNA from RNA Later and frozen samples. The amount of plant material from one cultivation chamber gives two RNA isolations. Each of the isolations gives Total RNA sufficient for at least two microarray analyses.
ERIC Educational Resources Information Center
Department of Agriculture, Washington, DC.
This kit contains a recipe book and various separately published materials to train food service staff in implementing the new breakfast and lunch menus from the U. S. Department of Agriculture (USDA). A training manual provides background information on recipe selection, development, and testing; orients staff to the recipe format; explains and…
Pradeep, Jothimani; Ambroise, Stanley; Gunasekaran, Dhandapany
2017-01-01
Introduction Query (Q) fever is an important zoonosis and a cause of concern for humans, due to the potential bioterrorism threat posed by the causative agent, Coxiella burnetii. Because of the danger of contracting the illness, isolation attempts are seldom made. Serological and molecular diagnostic tests are the main option. Aim To study the prevalence of acute Q fever in Puducherry and surrounding districts of Tamil Nadu, India, employing a new commercial Real-Time Polymerase Chain Reaction (RT-PCR) kit and confirming it by the gold standard Immunofluorescence Assay (IFA). Materials and Methods Acute phase blood samples from 72 consecutive febrile patients and 24 healthy individuals were included in this prospective study. DNA was extracted from the buffy coats and preserved at -80°C. Detection of C. burnetii was carried out employing a commercial Real-Time PCR kit. Serum samples were tested for IgM (Phase I+II) and IgG (Phase I+II) by QM-120 and QG-120, Coxiella burnetii IFA Fuller Laboratories, California, USA. Sensitivity, Specificity, Positive Predictive Value (PPV) and Negative Predictive Value (NPV) were calculated keeping IFA as the reference. Results Presumptive diagnosis of acute Q fever was made in two febrile patients by the Genesig Easy kit (2.78%). In addition to these two PCR positive cases, one more patient was positive for both Phase II IgM and Phase II IgG antibodies by the gold standard IFA. All 24 healthy controls were negative for Q fever by both PCR and IFA. The sensitivity, specificity, NPV and PPV for Genesig Easy kit PCR were: 66.67%, 100%, 100% and 98.57 % respectively against IFA as the reference. Conclusion The true prevalence of Q fever in India and other developing countries is poorly understood, owing to the difficulties in the diagnosis of this infection. Since molecular diagnostic tests have good specificity and are mandated for confirmation of single acute samples, validation of commercial Q fever PCR kits is the need of the hour. Genesig Easy kit in our hands was found to be reliable with the moderate sensitivity and high specificity. Performing both PCR (with acute specimens) and IFA (with paired sera) would be ideal for Q fever diagnosis. PMID:29207703
Production of UC-labeled gas in BACTEC Neisseria Differentiation kits by Neisseria cinerea
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boyce, J.M.; Mitchell, E.B. Jr.; Knapp, J.S.
1985-09-01
Six strains of Neisseria cinerea were tested in BACTEC Neisseria Differentiation kits (Johnston Laboratories, Inc., Towson, Md.), and all yielded positive glucose growth indices and negative maltose and fructose growth indices. These results were similar to those achieved with Neisseria gonorrhoeae. However, most of the N. cinerea isolates tested yielded 3-h glucose growth indices that were lower than those obtained with gonococci. UC-labeled gas was produced significantly faster by N. gonorrhoeae than by N. cinerea. Additional studies suggested that the UC-labeled gas produced by N. cinerea was carbon dioxide. N. cinerea strains were similar to Branhamella catarrhalis strains because bothmore » species failed to produce detectable acid from glucose, maltose, sucrose, fructose, and lactose in cysteine-tryptic agar media. However, in contrast to N. cinerea strains, B. catarrhalis strains did not metabolize glucose in BACTEC Neisseria Differentiation kits.« less
Modifying surface properties of KIT-6 zeolite with Ni and V for enhancing catalytic CO methanation
NASA Astrophysics Data System (ADS)
Cao, Hong-Xia; Zhang, Jun; Guo, Cheng-Long; Chen, Jingguang G.; Ren, Xiang-Kun
2017-12-01
The surface of the KIT-6 zeolite was modified with different amounts of Ni and V to promote the catalytic properties for CO methanation. A series of xNi-yV/KIT-6 with various Ni and V contents were prepared by the incipient-wetness impregnation method. The modified surfaces were characterized using N2 adsorption-desorption, Brunauer-Emmett-Teller (BET), X-ray diffraction (XRD), hydrogen temperature-programmed reduction (H2-TPR), Fourier transformed infrared spectroscopy (FT-IR), Raman, X-ray photoelectron spectroscopy (XPS), transmission electron microscope (TEM), and energy-dispersive X-ray spectroscopy (EDX), respectively. The characterization results illustrated that the modification of V species was able to significantly promote low-temperature catalytic performance below 350 °C compared to that of unmodified Ni/KIT-6, which was likely due to an increase in the H2 uptake accompanied by enhanced CO dissociation derived from stronger electron transfer from V species to Ni0. Correspondingly, the xNi-yV/KIT-6 catalysts exhibited a distinct enhancement in CO conversion, CH4 selectivity and CH4 yield over unmodified Ni/KIT-6. Among all catalysts, 20Ni-2V/KIT-6 showed the best catalytic performance, corresponding to nearly 100% CO conversion and 85% CH4 yield at a low temperature of 300 °C. Furthermore, 20Ni-2V/KIT-6 presented enhanced coking-resistant and anti-sintering properties during a 60h-lifetime test at 500 °C and 1 atm with a high weight hourly space velocity (WHSV) of 60000 ml/g/h.
Derouin, F.; Garin, Y. J.; Buffard, C.; Berthelot, F.; Petithory, J. C.
1994-01-01
A collaborative study conducted by the French National Agency for Quality Control in Parasitology (CNQP) and various manufacturers of ELISA kits, represented by the Association of Laboratory Reagent Manufacturers (SFRL) compared the toxoplasmosis IgG antibody titres obtained with different ELISA-IgG kits and determined the relationships between the titres obtained by these techniques and the titre defined in international units (IU). Fifty-one serum samples with toxoplasmosis antibody titres ranging from 0 to 900 IU were tested in two successive studies with 16 ELISA-IgG kits. For the negative sera, false-positive reactions were observed with one kit. For the positive sera, the titres observed in ELISA were generally higher than those expressed in IU. Above 250 IU, the very wide variability of the titres found with the different ELISA kits renders any comparative analysis impossible. For titres below 250 IU, the results are sufficiently homogeneous to permit the use of regression analysis to study how the results for each ELISA kit compare with the mean results for the other kits. The slope of the line of regression shows a tendency to over-titration or under-titration compared with the results of the other manufacturers; the ordinate at the origin reflects the positivity threshold of the reaction and can be used to assess the risk of a lack of sensitivity (high threshold) or of specificity (threshold too low). On the whole, the trends revealed for a given manufacturer are constant from one study to the other. Within this range of titres, regression analysis also reveals the general tendency of ELISA kits to overestimate the titres by comparison with immunofluorescence.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:8205645
Using a Social Network Strategy to Distribute HIV Self-Test Kits to African American and Latino MSM.
Lightfoot, Marguerita A; Campbell, Chadwick K; Moss, Nicholas; Treves-Kagan, Sarah; Agnew, Emily; Kang Dufour, Mi-Suk; Scott, Hyman; Sa'id, Aria M; Lippman, Sheri A
2018-05-04
Men who have sex with men (MSM) continue to be disproportionately impacted globally by the HIV epidemic. Studies suggest that HIV Self-testing (HIVST) is highly acceptable among MSM. Social network strategies to increase testing are effective in reaching MSM, particularly MSM of color, who may not otherwise test. We tested a social-network based strategy to distribute HIVST kits to African American and Latino MSM. This study was conducted in Alameda County, California a large, urban/suburban county with an HIV epidemic mirroring the national HIV epidemic. From January 2016 to March 2017, 30 AAMSM, LMSM, and Transgender women were trained as peer recruiters and asked to distribute five self-test kits to MSM social network members and support those who test positive in linking to care. Testers completed an online survey following their test. We compared peer-distributed HIVST testing outcomes to outcomes from Alameda County's targeted, community-based HIV testing programs using chi-squared tests. Peers distributed HIVST to 143 social and sexual network members, of whom 110 completed the online survey. Compared to MSM who utilized the County's sponsored testing programs, individuals reached through the peer-based self-testing strategy were significantly more likely to have never tested for HIV (3.51% vs. 0.41%, p<0.01) and to report a positive test result (6.14% vs 1.49%, p<0.01). Findings suggest that a network-based strategy for self-test distribution is a promising intervention to increase testing uptake and reduce undiagnosed infections among African American and Latino MSM.
Lipson, S M; Leonardi, G P; Salo, R J; Schutzbank, T E; Kaplan, M H
1990-01-01
Sixty-five stool specimens obtained from children suffering from gastroenteritis were tested for the presence of antigen to rotavirus by the Abbott TestPack Rotavirus (TestPack) enzyme immunoassay kit. The Kallestad Pathfinder enzyme immunoassay, polyacrylamide gel electrophoresis, immune electron microscopy, and virus isolation were utilized as reference assays. Fifty-four specimens were in accord by TestPack and Kallestad Pathfinder. Among 11 discordant specimens positive with TestPack but negative by Kallestad Pathfinder, rotavirus was not identified by polyacrylamide gel electrophoresis, immune electron microscopy, or isolation in primary African green monkey kidney cell cultures. TestPack displayed a performance specificity of 83%. The inordinately high number of stool specimens reported as false-positive by TestPack precludes the incorporation of this antigen detection kit into our routine regimen of diagnostic virologic testing. Images PMID:2166074
3D vision upgrade kit for TALON robot
NASA Astrophysics Data System (ADS)
Edmondson, Richard; Vaden, Justin; Hyatt, Brian; Morris, James; Pezzaniti, J. Larry; Chenault, David B.; Tchon, Joe; Barnidge, Tracy; Kaufman, Seth; Pettijohn, Brad
2010-04-01
In this paper, we report on the development of a 3D vision field upgrade kit for TALON robot consisting of a replacement flat panel stereoscopic display, and multiple stereo camera systems. An assessment of the system's use for robotic driving, manipulation, and surveillance operations was conducted. The 3D vision system was integrated onto a TALON IV Robot and Operator Control Unit (OCU) such that stock components could be electrically disconnected and removed, and upgrade components coupled directly to the mounting and electrical connections. A replacement display, replacement mast camera with zoom, auto-focus, and variable convergence, and a replacement gripper camera with fixed focus and zoom comprise the upgrade kit. The stereo mast camera allows for improved driving and situational awareness as well as scene survey. The stereo gripper camera allows for improved manipulation in typical TALON missions.
Lodh, Nilanjan; Mikita, Kei; Bosompem, Kwabena M; Anyan, William K; Quartey, Joseph K; Otchere, Joseph; Shiff, Clive J
2017-09-01
Schistosomes are easily transmitted and high chance of repeat infection, so if control strategies based on targeted mass drug administration (MDA) are to succeed it is essential to have a test that is sensitive, accurate and simple to use. It is known and regularly demonstrated that praziquantel does not always eliminate an infection so in spite of the successes of control programs a residual of the reservoir survives to re-infect snails. The issue of diagnostic sensitivity becomes more critical in the assessment of program effectiveness. While serology, such as antigen capture tests might improve sensitivity, it has been shown that the presence of species-specific DNA fragments will indicate, most effectively, the presence of active parasites. Polymerase chain reaction (PCR) can amplify and detect DNA from urine residue captured on Whatman No. 3 filter paper that is dried after filtration. Previously we have detected S. mansoni and S. haematobium parasite-specific small repeat DNA fragment from filtered urine on filter paper by PCR. In the current study, we assessed the efficacy of detection of 86 urine samples for either or both schistosome parasites by PCR and loop-mediated isothermal amplification (LAMP) that were collected from a low to moderate transmission area in Ghana. Two different DNA extraction methods, standard extraction kit and field usable LAMP-PURE kit were also evaluated by PCR and LAMP amplification. With S. haematobium LAMP amplification for both extractions showed similar sensitivity and specificity when compared with PCR amplification (100%) verified by gel electrophoresis. For S. mansoni sensitivity was highest for LAMP amplification (100%) for standard extraction than PCR and LAMP with LAMP-PURE (99% and 94%). The LAMP-PURE extraction produced false negatives, which require further investigation for this field usable extraction kit. Overall high positive and negative predictive values (90% - 100%) for both species demonstrated a highly robust approach. The LAMP approach is close to point of care use and equally sensitive and specific to detection of species-specific DNA by PCR. LAMP can be an effective means to detect low intensity infection due to its simplicity and minimal DNA extraction requirement. This will enhance the effectiveness of surveillance and MDA control programs of schistosomiasis. Copyright © 2017 Elsevier B.V. All rights reserved.
Koskinen, M T; Wellenberg, G J; Sampimon, O C; Holopainen, J; Rothkamp, A; Salmikivi, L; van Haeringen, W A; Lam, T J G M; Pyörälä, S
2010-12-01
Fast and reliable identification of the microorganisms causing mastitis is important for management of the disease and for targeting antimicrobial treatment. Methods based on PCR are being used increasingly in mastitis diagnostics. Comprehensive field comparisons of PCR and traditional milk bacteriology have not been available. The results of a PCR kit capable of detecting 11 important etiological agents of mastitis directly from milk in 4h were compared with those of conventional bacterial culture (48h). In total, 1,000 quarter milk samples were taken from cows with clinical or subclinical mastitis, or from clinically healthy quarters with low somatic cell count (SCC). Bacterial culture identified udder pathogens in 600/780 (77%) of the clinical samples, whereas PCR identified bacteria in 691/780 (89%) of the clinical samples. The PCR analysis detected major pathogens in a large number of clinical samples that were negative for the species in culture. These included 53 samples positive for Staphylococcus aureus by PCR, but negative by culture. A total of 137 samples from clinical mastitis, 5 samples from subclinical mastitis, and 1 sample from a healthy quarter were positive for 3 or more bacterial species in PCR, whereas culture identified 3 or more species in 60 samples from clinical mastitis. Culture identified a species not targeted by the PCR test in 44 samples from clinical mastitis and in 9 samples from subclinical mastitis. Low SCC samples provided a small number of positive results both in culture (4/93; 4.3%) and by PCR (7/93; 7.5%). In conclusion, the PCR kit provided several benefits over conventional culture, including speed, automated interpretation of results, and increased sensitivity. This kit holds much promise as a tool to complement traditional methods in identification of pathogens. In conventional mastitis bacteriology, a sample with 3 or more species is considered contaminated, and resampling of the cow is recommended. Further study is required to investigate how high sensitivity of PCR and its quantitative features can be applied to improve separation of relevant udder pathogens from likely contaminants in samples where multiple species are detected. Furthermore, increasing the number of species targeted by the PCR test would be advantageous. Copyright © 2010 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Kaman, Wendy E; Andrinopoulou, Eleni-Rosalina; Hays, John P
2013-01-01
The proper development and implementation of point-of-care (POC) diagnostics requires knowledge of the perceived requirements and barriers to their implementation. To determine the current requirements and perceived barriers to the introduction of POC diagnostics in the field of medical microbiology (MM)-POC a prospective online survey (TEMPOtest-QC) was established. The TEMPOtest-QC survey was online between February 2011 and July 2012 and targeted the medical community, POC test diagnostic manufacturers, general practitioners, and the general public. In total, 293 individuals responded to the survey, including 91 (31%) medical microbiologists, 39 (13%) nonmedical microbiologists, 25 (9%) employees of POC test manufacturers, and 138 (47%) members of the general public. Responses were received from 18 different European countries, with the largest percentage of these living in The Netherlands (52%). The majority (>50%) of medical specialists regarded the development of MM-POC for blood culture and hospital acquired infections as "absolutely necessary", but were much less favorable towards their use in the home environment. Significant differences in perceptions between medical specialists and the general public included the: (1) Effect on quality of patient care; (2) Ability to better monitor patients; (3) Home testing and the doctor-patient relationship; and (4) MM-POC interpretation. Only 34.7% of the general public is willing to pay more than a€10 ($13) for a single MM-POC test, with 85.5% preferring to purchase their MM-POC test from a pharmacy. The requirements for the proper implementation of MM-POC were found to be generally similar between medical specialists and POC test kit manufacturers. The general public was much more favorable with respect to a perceived improvement in the quality of healthcare that these tests would bring to the hospital and home environment.
Code of Federal Regulations, 2012 CFR
2012-01-01
...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...
Code of Federal Regulations, 2013 CFR
2013-01-01
...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...
Code of Federal Regulations, 2010 CFR
2010-01-01
...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...
Code of Federal Regulations, 2014 CFR
2014-01-01
...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...
Code of Federal Regulations, 2011 CFR
2011-01-01
...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...
... Medical Procedures In Vitro Diagnostics Home Use Tests Cholesterol Share Tweet Linkedin Pin it More sharing options ... a home-use test kit to measure total cholesterol. What cholesterol is: Cholesterol is a fat (lipid) ...
Praud, Anne; Champion, Jean-Luc; Corde, Yannick; Drapeau, Antoine; Meyer, Laurence; Garin-Bastuji, Bruno
2012-07-09
Brucella ovis causes an infectious disease responsible for infertility and subsequent economic losses in sheep production. The standard serological test to detect B. ovis infection in rams is the complement fixation test (CFT), which has imperfect sensitivity and specificity in addition to technical drawbacks. Other available tests include the indirect enzyme-linked immunosorbent assays (I-ELISA) but no I-ELISA kit has been fully evaluated.The study aimed to compare an I-ELISA kit and the standard CFT. Our study was carried out on serum samples from 4599 rams from the South of France where the disease is enzootic. A Bayesian approach was used to estimate tests characteristics (diagnostic sensitivity, Se and diagnostic specificity, Sp). The tests were then studied together in order to optimise testing strategies to detect B. ovis. After optimising the cut-off values in order to avoid doubtful results without deteriorating the concordance between the results of the two tests, the I-ELISA appeared to be slightly more sensitive than CFT (Se I-ELISA=0.917 [0.822; 0.992], 95% Credibility Interval (CrI) compared to Se CFT=0.860 [0.740; 0.967], 95% CrI). However, CFT was slightly more specific than I-ELISA (Sp CFT=0.988 [0.947; 1.0], 95% CrI) compared to Sp I-ELISA =0.952 [0.901; 1.0], 95% CrI).The tests were then associated with two different interpretation schemes. The series association increased the specificity of screening and could be used for pre-movement testing in rams from uninfected flocks. The parallel association increased sequence sensitivity, thus appearing more suitable for eradicating the disease in infected flocks. The high sensitivity and acceptable specificity of this I-ELISA kit support its potential interest to avoid the limitations of CFT. The two tests could also be used together or combined with other diagnostic methods such as semen culture to improve the testing strategy. The choice of test sequence and interpretation criteria depends on the epidemiological context, screening objectives and the financial and practical constraints.
Preliminary characterization of digestive enzymes in freshwater mussels
Sauey, Blake W.; Amberg, Jon J.; Cooper, Scott T.; Grunwald, Sandra K.; Newton, Teresa J.; Haro, Roger J.
2015-01-01
Resource managers lack an effective chemical tool to control the invasive zebra mussel Dreissena polymorpha. Zebra mussels clog water intakes for hydroelectric companies, harm unionid mussel species, and are believed to be a reservoir of avian botulism. Little is known about the digestive physiology of zebra mussels and unionid mussels. The enzymatic profile of the digestive glands of zebra mussels and native threeridge (Amblema plicata) and plain pocketbook mussels (Lampsilis cardium) are characterized using a commercial enzyme kit, api ZYM, and validated the kit with reagent-grade enzymes. A linear correlation was shown for only one of nineteen enzymes, tested between the api ZYM kit and a specific enzyme kit. Thus, the api ZYM kit should only be used to make general comparisons of enzyme presence and to observe trends in enzyme activities. Enzymatic trends were seen in the unionid mussel species, but not in zebra mussels sampled 32 days apart from the same location. Enzymatic classes, based on substrate, showed different trends, with proteolytic and phospholytic enzymes having the most change in relative enzyme activity.
Bastani, Roshan; Danao, Leda L.; Antonio, Cynthia; Garcia, Gabriel M.; Crespi, Catherine M.
2010-01-01
Objectives. We conducted 1 of the first community-based trials to develop a multicomponent intervention that would increase colorectal cancer screening among an Asian American population. Methods. Filipino Americans (n = 548) nonadherent to colorectal cancer (CRC) screening guidelines were randomized into an intervention group that received an education session on CRC screening and free fecal occult blood test (FOBT) kits; a second intervention group that received an education session but no free FOBT kits; and a control group that received an education session on the health benefits of physical activity. Results. Self-reported CRC screening rates during the 6-month follow-up period were 30%, 25%, and 9% for participants assigned to intervention with FOBT kit, intervention without the kit, and control group, respectively. Participants in either of the 2 intervention groups were significantly more likely to report screening at follow-up than were participants in the control group. Conclusions. A multicomponent intervention that includes an educational group session in a community setting can significantly increase CRC screening among Filipino Americans, even when no free FOBT kits are distributed. PMID:20864724
Programmable logic controller performance enhancement by field programmable gate array based design.
Patel, Dhruv; Bhatt, Jignesh; Trivedi, Sanjay
2015-01-01
PLC, the core element of modern automation systems, due to serial execution, exhibits limitations like slow speed and poor scan time. Improved PLC design using FPGA has been proposed based on parallel execution mechanism for enhancement of performance and flexibility. Modelsim as simulation platform and VHDL used to translate, integrate and implement the logic circuit in FPGA. Xilinx's Spartan kit for implementation-testing and VB has been used for GUI development. Salient merits of the design include cost-effectiveness, miniaturization, user-friendliness, simplicity, along with lower power consumption, smaller scan time and higher speed. Various functionalities and applications like typical PLC and industrial alarm annunciator have been developed and successfully tested. Results of simulation, design and implementation have been reported. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.
Samsung Salmonella Detection Kit. AOAC Performance Tested Method(SM) 021203.
Li, Jun; Cheung, Win Den; Opdyke, Jason; Harvey, John; Chong, Songchun; Moon, Cheol Gon
2012-01-01
Salmonella, one of the most common causes of foodborne illness, is a significant public health concern worldwide. There is a need in the food industry for methods that are simple, rapid, and sensitive for the detection of foodborne pathogens. In this study, the Samsung Salmonella Detection Kit, a real-time PCR assay for the detection of Salmonella, was evaluated according to the current AOAC guidelines. The validation consisted of lot-to-lot consistency, stability, robustness, and inclusivity/exclusivity studies, as well as a method comparison of 10 different food matrixes. In the validation, the Samsung Salmonella Detection Kit was used in conjunction with the Applied Biosystems StepOnePlus PCR system and the Samsung Food Testing Software for the detection of Salmonella species. The performance of the assays was compared to the U.S. Department of Agriculture/Food Safety and Inspection Service-Microbiology Laboratory Guidebook (USDA/FSIS-MLG) 4.05: Isolation and Identification of Salmonella from Meat, Poultry, Pasteurized Egg, and Catfish and the and U.S. Food and Drug Administration/Bacteriological Analytical Manual (FDA/BAM) Chapter 5 Salmonella reference methods. The validation was conducted using an unpaired study design for detection of Salmonella spp. in raw ground beef, raw pork, raw ground pork, raw chicken wings, raw salmon, alfalfa sprouts, pasteurized orange juice, peanut butter, pasteurized whole milk, and shell eggs. The Samsung Salmonella Detection Kit demonstrated lot-to-lot consistency among three independent lots as well as ruggedness with minor modifications to changes in enrichment incubation time, enrichment incubation temperature, and DNA sample volume for PCR reaction. Stability was observed for 13 months at -20 degrees C and 3 months at 5 degrees C. For the inclusivity/exclusivity study, the Samsung Salmonella Detection Kit correctly identified 147 Salmonella species isolates out of 147 isolates tested from each of three different enrichment broths (a total of 441 isolates detected), and correctly excluded all 31 nontarget strains analyzed. For the method comparison, statistical analysis was conducted according to the Mantel-Haenszel Chi-square formula for unpaired test portions, and there was no significant difference in the number of positive samples detected between the Samsung Salmonella Detection Kit and the USDA/FSIS-MLG and FDA/BAM reference methods for all 10 food matrixes.
Cardiac hypertrophy limits infarct expansion after myocardial infarction in mice.
Iismaa, Siiri E; Li, Ming; Kesteven, Scott; Wu, Jianxin; Chan, Andrea Y; Holman, Sara R; Calvert, John W; Haq, Ahtesham Ul; Nicks, Amy M; Naqvi, Nawazish; Husain, Ahsan; Feneley, Michael P; Graham, Robert M
2018-04-17
We have previously demonstrated that adult transgenic C57BL/6J mice with CM-restricted overexpression of the dominant negative W v mutant protein (dn-c-kit-Tg) respond to pressure overload with robust cardiomyocyte (CM) cell cycle entry. Here, we tested if outcomes after myocardial infarction (MI) due to coronary artery ligation are improved in this transgenic model. Compared to non-transgenic littermates (NTLs), adult male dn-c-kit-Tg mice displayed CM hypertrophy and concentric left ventricular (LV) hypertrophy in the absence of an increase in workload. Stroke volume and cardiac output were preserved and LV wall stress was markedly lower than that in NTLs, leading to a more energy-efficient heart. In response to MI, infarct size in adult (16-week old) dn-c-kit-Tg hearts was similar to that of NTL after 24 h but was half that in NTL hearts 12 weeks post-MI. Cumulative CM cell cycle entry was only modestly increased in dn-c-kit-Tg hearts. However, dn-c-kit-Tg mice were more resistant to infarct expansion, adverse LV remodelling and contractile dysfunction, and suffered no early death from LV rupture, relative to NTL mice. Thus, pre-existing cardiac hypertrophy lowers wall stress in dn-c-kit-Tg hearts, limits infarct expansion and prevents death from myocardial rupture.
Harik-Khan, R; Moats, W A
1995-01-01
A procedure for identifying and quantitating violative beta-lactams in milk is described. This procedure integrates beta-lactam residue detection kits with the multiresidue automated liquid chromatographic (LC) cleanup method developed in our laboratory. Spiked milk was deproteinized, extracted, and subjected to reversed-phase LC using a gradient program that concentrated the beta-lactams. Amoxicillin, ampicillin, cephapirin, ceftiofur, cloxacillin, and penicillin G were, thus, separated into 5 fractions that were subsequently tested for activity by using 4 kits. beta-lactams in the positive fractions were quantitated by analytical LC methods developed in our laboratory. The LC cleanup method separated beta-lactam antibiotics from each other and from interferences in the matrix and also concentrated the antibiotics, thus increasing the sensitivity of the kits to the beta-lactam antibiotics. The procedure facilitated the task of identifying and measuring the beta-lactam antibiotics that may be present in milk samples.
NASA Astrophysics Data System (ADS)
2010-07-01
WE RECOMMEND Good Practice in Science Teaching: What Research Has to Say Book explores and summarizes the research Steady State Bottle Kit Another gem from SEP Sciencescope Datalogging Balance Balance suits everyday use Sciencescope Spectrophotometer Device displays clear spectrum WORTH A LOOK The Babylonian Theorem Text explains ancient Egyptian mathematics BrainBox360 (Physics Edition) Video game tests your knowledge Teaching and Learning Science: Towards a Personalized Approach Book reveals how useful physics teachers really are PAPERSHOW Gadget kit is useful but has limitations Robotic Arm Kit with USB PC Interface Robot arm teaches programming WEB WATCH Simple applets teach complex topics
Siegfried, Konrad; Hahn-Tomer, Sonja; Koelsch, Andreas; Osterwalder, Eva; Mattusch, Juergen; Staerk, Hans-Joachim; Meichtry, Jorge M; De Seta, Graciela E; Reina, Fernando D; Panigatti, Cecilia; Litter, Marta I; Harms, Hauke
2015-05-21
Numerous articles have reported the occurrence of arsenic in drinking water in Argentina, and the resulting health effects in severely affected regions of the country. Arsenic in drinking water in Argentina is largely naturally occurring due to elevated background content of the metalloid in volcanic sediments, although, in some regions, mining can contribute. While the origin of arsenic release has been discussed extensively, the problem of drinking water contamination has not yet been solved. One key step in progress towards mitigation of problems related with the consumption of As-containing water is the availability of simple detection tools. A chemical test kit and the ARSOlux biosensor were evaluated as simple analytical tools for field measurements of arsenic in the groundwater of Rafaela (Santa Fe, Argentina), and the results were compared with ICP-MS and HPLC-ICP-MS measurements. A survey of the groundwater chemistry was performed to evaluate possible interferences with the field tests. The results showed that the ARSOlux biosensor performed better than the chemical field test, that the predominant species of arsenic in the study area was arsenate and that arsenic concentration in the studied samples had a positive correlation with fluoride and vanadium, and a negative one with calcium and iron.
Siegfried, Konrad; Hahn-Tomer, Sonja; Koelsch, Andreas; Osterwalder, Eva; Mattusch, Juergen; Staerk, Hans-Joachim; Meichtry, Jorge M.; De Seta, Graciela E.; Reina, Fernando D.; Panigatti, Cecilia; Litter, Marta I.; Harms, Hauke
2015-01-01
Numerous articles have reported the occurrence of arsenic in drinking water in Argentina, and the resulting health effects in severely affected regions of the country. Arsenic in drinking water in Argentina is largely naturally occurring due to elevated background content of the metalloid in volcanic sediments, although, in some regions, mining can contribute. While the origin of arsenic release has been discussed extensively, the problem of drinking water contamination has not yet been solved. One key step in progress towards mitigation of problems related with the consumption of As-containing water is the availability of simple detection tools. A chemical test kit and the ARSOlux biosensor were evaluated as simple analytical tools for field measurements of arsenic in the groundwater of Rafaela (Santa Fe, Argentina), and the results were compared with ICP-MS and HPLC-ICP-MS measurements. A survey of the groundwater chemistry was performed to evaluate possible interferences with the field tests. The results showed that the ARSOlux biosensor performed better than the chemical field test, that the predominant species of arsenic in the study area was arsenate and that arsenic concentration in the studied samples had a positive correlation with fluoride and vanadium, and a negative one with calcium and iron. PMID:26006123
Automated inverse computer modeling of borehole flow data in heterogeneous aquifers
NASA Astrophysics Data System (ADS)
Sawdey, J. R.; Reeve, A. S.
2012-09-01
A computer model has been developed to simulate borehole flow in heterogeneous aquifers where the vertical distribution of permeability may vary significantly. In crystalline fractured aquifers, flow into or out of a borehole occurs at discrete locations of fracture intersection. Under these circumstances, flow simulations are defined by independent variables of transmissivity and far-field heads for each flow contributing fracture intersecting the borehole. The computer program, ADUCK (A Downhole Underwater Computational Kit), was developed to automatically calibrate model simulations to collected flowmeter data providing an inverse solution to fracture transmissivity and far-field head. ADUCK has been tested in variable borehole flow scenarios, and converges to reasonable solutions in each scenario. The computer program has been created using open-source software to make the ADUCK model widely available to anyone who could benefit from its utility.
USDA-ARS?s Scientific Manuscript database
An accurate and simple-to-perform new version of a competitive ELISA (cELISA) kit that became commercially available in 2015 for testing of cattle for antibody to Anaplasma marginale was validated for detection of Anaplasma ovis antibody in domestic sheep. True positives and negatives were identifie...
Westman, Mark E; Malik, Richard; Hall, Evelyn; Norris, Jacqueline M
2016-06-01
We recently showed that two immunochromatography point-of-care FIV antibody test kits (Witness FeLV/FIV and Anigen Rapid FIV/FeLV) were able to correctly assign FIV infection status, irrespective of FIV vaccination history, using whole blood as the diagnostic specimen. A third FIV antibody test kit, SNAP FIV/FeLV Combo (an enzyme-linked immunosorbent assay [ELISA]), was unable to differentiate antibodies produced in response to FIV vaccination from those incited by FIV infection. The aim of this study was to determine if saliva is a suitable diagnostic specimen using the same well characterized feline cohort. FIV infection status of these cats had been determined previously using a combination of serology, polymerase chain reaction (PCR) testing and virus isolation. This final assignment was then compared to results obtained using saliva as the diagnostic specimen utilizing the same three point-of-care FIV antibody test kits and commercially available PCR assay (FIV RealPCR). In a population of cats where one third (117/356; 33%) were FIV-vaccinated, both immunochromatography test kits accurately diagnosed FIV infection using saliva via a centrifugation method, irrespective of FIV vaccination history. For FIV diagnosis using saliva, the specificity of Anigen Rapid FIV/FeLV and Witness FeLV/FIV was 100%, while the sensitivity of these kits was 96% and 92% respectively. SNAP FIV/FeLV Combo respectively. SNAP FIV/FeLV Combo had a specificity of 98% and sensitivity of 44%, while FIV RealPCR testing had a specificity of 100% and sensitivity of 72% using saliva. A revised direct method of saliva testing was trialed on a subset of FIV-infected cats (n=14), resulting in 14, 7 and 0 FIV positive results using Anigen Rapid FIV/FeLV, Witness FeLV/FIV and SNAP FIV/FeLV Combo, respectively. These results demonstrate that saliva can be used to diagnose FIV infection, irrespective of FIV vaccination history, using either a centrifugation method (Anigen Rapid FIV/FeLV and Witness FeLV/FIV) or a direct method (Anigen Rapid FIV/FeLV). Collection of a saliva specimen therefore provides an acceptable alternative to venipuncture (i) in fractious cats where saliva may be easier to obtain than whole blood, (ii) in settings when a veterinarian or trained technician is unavailable to collect blood and (iii) in shelters where FIV testing is undertaken prior to adoption but additional blood testing is not required. Copyright © 2016 Elsevier Ltd. All rights reserved.
Pham, Robyn; Cross, Suzanne; Fernandez, Bianca; Corson, Kathryn; Dillon, Kristen; Yackley, Coco; Davis, Melinda M
2017-01-01
Colorectal cancer (CRC) is the third leading cause of cancer death in the United States, yet 1 in 3 Americans have never been screened for CRC. Annual screening using fecal immunochemical tests (FITs) is often a preferred modality in populations experiencing CRC screening disparities. Although multiple studies evaluate the clinical effectiveness of FITs, few studies assess patient preferences toward kit characteristics. We conducted this community-led study to assess patient preferences for FIT characteristics and to use study findings in concert with clinical effectiveness data to inform regional FIT selection. We collaborated with local health system leaders to identify FITs and recruit age eligible (50 to 75 years), English or Spanish speaking community members. Participants completed up to 6 FITs and associated questionnaires and were invited to participate in a follow-up focus group. We used a sequential explanatory mixed-methods design to assess participant preferences and rank FIT kits. First, we used quantitative data from user testing to measure acceptability, ease of completion, and specimen adequacy through a descriptive analysis of 1) fixed response questionnaire items on participant attitudes toward and experiences with FIT kits, and 2) a clinical assessment of adherence to directions regarding collection, packaging, and return of specimens. Second, we analyzed qualitative data from focus groups to refine FIT rankings and gain deeper insight into the pros and cons associated with each tested kit. Seventy-six FITs were completed by 18 participants (Range, 3 to 6 kits per participant). Over half (56%, n = 10) of the participants were Hispanic and 50% were female (n = 9). Thirteen participants attended 1 of 3 focus groups. Participants preferred FITs that were single sample, used a probe and vial for sample collection, and had simple, large-font instructions with colorful pictures. Participants reported challenges using paper to catch samples, had difficulty labeling tests, and emphasized the importance of having care team members provide verbal instructions on test completion and follow-up support for patients with abnormal results. FIT rankings from most to least preferred were OC-Light, Hemosure iFOB Test, InSure FIT, QuickVue, OneStep+, and Hemoccult ICT. FIT characteristics influenced patient's perceptions of test acceptability and feasibility. Health system leaders, payers, and clinicians should select FITs that are both clinically effective and incorporate patient preferred test characteristics. Consideration of patient preferences may facilitate FIT return, especially in populations at higher risk for experiencing CRC screening disparities. © Copyright 2017 by the American Board of Family Medicine.
Disposable collection kit for rapid and reliable collection of saliva.
Yamaguchi, Masaki; Tezuka, Yuki; Takeda, Kazunori; Shetty, Vivek
2015-01-01
To describe and evaluate disposable saliva collection kit for rapid, reliable, and reproducible collection of saliva samples. The saliva collection kit comprised of a saliva absorbent swab and an extractor unit was used to retrieve whole saliva samples from 10 subjects. The accuracy and precision of the extracted volumes (3, 10, and 30 μl) were compared to similar volumes drawn from control samples obtained by passive drool. Additionally, the impact of kit collection method on subsequent immunoassay results was verified by assessing salivary cortisol levels in the samples and comparing them to controls. The recovered volumes for the whole saliva samples were 3.85 ± 0.28, 10.79 ± 0.95, and 31.18 ± 1.72 μl, respectively (CV = 8.76%) and 2.91 ± 0.19, 9.75 ± 0.43, and 29.64 ± 0.91 μl, respectively, (CV = 6.36%) for the controls. There was a close correspondence between the salivary cortisol levels from the saliva samples obtained by the collection kit and the controls (R(2) > 0.96). The disposable saliva collection kit allows accurate and repeatable collection of fixed amounts of whole saliva and does not interfere with subsequent measurements of salivary cortisol. The simple collection process, lack of elaborate specimen recovery steps, and the short turnaround time (<3 min) should render the kit attractive to test subjects and researchers alike. © 2015 Wiley Periodicals, Inc.
Shin, So Youn; Kwon, Kye Chul; Park, Jong Woo; Kim, Ji Myung; Shin, So Young; Koo, Sun Hoe
2012-01-01
Bacterial meningitis is an infectious disease with high rates of mortality and high frequency of severe sequelae. Early identification of causative bacterial and viral pathogens is important for prompt and proper treatment of meningitis and for prevention of life-threatening clinical outcomes. In the present study, we evaluated the value of the Seeplex Meningitis ACE Detection kit (Seegene Inc., Korea), a newly developed multiplex PCR kit employing dual priming oligonucleotide methods, for diagnosing acute meningitis. Analytical sensitivity of the kit was studied using reference strains for each pathogen targeted by the kit, while it's analytical specificity was studied using the human genome DNA and 58 clinically well-identified reference strains. For clinical validation experiment, we used 27 control cerebrospinal fluid (CSF) samples and 78 clinical CSF samples collected from patients at the time of diagnosis of acute meningitis. The lower detection limits ranged from 10(1) copies/µL to 5×10(1) copies/µL for the 12 viral and bacterial pathogens targeted. No cross-reaction was observed. In the validation study, high detection rate of 56.4% was obtained. None of the control samples tested positive, i.e., false-positive results were absent. The Seeplex Meningitis ACE Detection kit showed high sensitivity, specificity, and detection rate for the identification of pathogens in clinical CSF samples. This kit may be useful for rapid identification of important acute meningitis-causing pathogens.
Shin, So Youn; Kwon, Kye Chul; Park, Jong Woo; Kim, Ji Myung; Shin, So Young
2012-01-01
Background Bacterial meningitis is an infectious disease with high rates of mortality and high frequency of severe sequelae. Early identification of causative bacterial and viral pathogens is important for prompt and proper treatment of meningitis and for prevention of life-threatening clinical outcomes. In the present study, we evaluated the value of the Seeplex Meningitis ACE Detection kit (Seegene Inc., Korea), a newly developed multiplex PCR kit employing dual priming oligonucleotide methods, for diagnosing acute meningitis. Methods Analytical sensitivity of the kit was studied using reference strains for each pathogen targeted by the kit, while it's analytical specificity was studied using the human genome DNA and 58 clinically well-identified reference strains. For clinical validation experiment, we used 27 control cerebrospinal fluid (CSF) samples and 78 clinical CSF samples collected from patients at the time of diagnosis of acute meningitis. Results The lower detection limits ranged from 101 copies/µL to 5×101 copies/µL for the 12 viral and bacterial pathogens targeted. No cross-reaction was observed. In the validation study, high detection rate of 56.4% was obtained. None of the control samples tested positive, i.e., false-positive results were absent. Conclusions The Seeplex Meningitis ACE Detection kit showed high sensitivity, specificity, and detection rate for the identification of pathogens in clinical CSF samples. This kit may be useful for rapid identification of important acute meningitis-causing pathogens. PMID:22259778
2012-01-01
Background Vulvar carcinomas are rare tumors, and there is limited data regarding molecular alterations. To our knowledge there are no published studies on c-KIT and squamous cell carcinomas of the vulva (VSCC). Although there are a significant number of other tumor types which express c-KIT, there remains controversy as to its relationship to patient outcome. Thus, we wished to investigate such controversial findings to determine the prognostic importance of c-KIT by evaluating its protein and mRNA expression in VSCCs, correlating these findings with clinicopathological features and Human Papillomavirus (HPV) infection. Methods c-KIT expression was scored by immunohistochemistry (IHC) as positive or negative in 139 formalin-fixed paraffin-embedded (FFPE) cases of vulvar carcinomas arrayed in a tissue microarray (TMA) using the DAKO® A4502 rabbit polyclonal c-KIT antibody (diluted 1:100). c-KIT mRNA was evaluated by qRT-PCR in 34 frozen samples from AC Camargo Hospital Biobank (17 tumoral and 17 non-tumoral samples) using TaqMan probes–Applied Biosystems [Hs00174029_m1]. HPV genotyping was assessed in 103 samples using Linear Array® HPV Genotyping Test kit (Roche Molecular Diagnostics, Basel, Switzerland). All results obtained were correlated with clinical and pathological data of the patients. Results c-KIT protein was positive by immunohistochemistry in 70.5% of the cases and this was associated with a higher global survival (p = 0.007), a higher recurrence-free survival (p < 0.0001), an absence of associated lesions (p = 0.001), lymph node metastasis (p = 0.0053), and HPV infection (p = 0.034). Furthermore, c-KIT mRNA quantitation revealed higher levels of transcripts in normal samples compared to tumor samples (p = 0,0009). Conclusions Our findings indicate that those vulvar tumors staining positively for c-KIT present better prognosis. Thus, positivity of c-KIT as evaluated by IHC may be a good predictor for use of more conservative surgery techniques and lymph node dissection in vulvar cancer. So part of the essence of our study is to see the possibility of translating our current results from the bench to the bedside. This will help provide patients a more appropriate, less mutilating treatment, in order to keep the maximum physical and psychic quality as possible to these women. PMID:22839358
Online social networking for HIV education and prevention: a mixed-methods analysis.
Young, Sean D; Jaganath, Devan
2013-02-01
The purpose of this study is to use mixed (qualitative/quantitative) methods to determine (1) the feasibility and acceptability of using online social networking to facilitate HIV-related discussions and (2) the relationship between HIV-related online discussions and requests for a home-based HIV testing kit among men who have sex with men. Participants, primarily African American and Latino, were invited to join a "secret" group on the social networking Web site, Facebook. Peer leaders, trained in HIV prevention, posted HIV-related content. Participants were not obligated to respond to discussions or remain within the group. Participant public group conversations were qualitatively and thematically analyzed. Quantitative methods tested associations between qualitative data, participants' demographic information, and likelihood of requesting a home-based HIV testing kit. Latino and African American participants (n = 57) voluntarily used Facebook to discuss the following HIV-related topics (n = 485 conversations): prevention and testing, knowledge, stigma, and advocacy. Older participants more frequently discussed prevention and testing, stigma, and advocacy, although younger participants more frequently discussed HIV knowledge-related conversations. As the study progressed, the proportion of messages related to prevention and testing and HIV stigma increased. Multivariate analysis showed that participants posting about HIV prevention and testing (compared with those who did not) were significantly more likely to request an HIV testing kit (odds ratio, 11.14; P = 0.001). Facebook can serve as an innovative forum to increase both HIV prevention discussions and HIV testing requests among at-risk groups.
Yang, Jeng-Fu; Lin, Ya-Yun; Huang, Jee-Fu; Liu, Shu-Fen; Chu, Pei-Yu; Hsieh, Ming-Yen; Lin, Zu-Yau; Chen, Shinn-Cherng; Wang, Liang-Yen; Dai, Chia-Yen; Chuang, Wan-Long; Yu, Ming-Lung
2009-08-01
With an estimated 350-400 million people worldwide chronically infected with hepatitis B virus (HBV), and the subsequent serious complications caused by liver damage including cirrhosis, liver failure, and hepatocellular carcinoma, HBV infection remains a global health issue, particularly in Taiwan, an HBV-hyperendemic area. Sensitive and accurate quantification of HBV DNA is necessary to monitor patients with chronic hepatitis B who are receiving antiviral therapy to determine treatment response and adapt therapy. We evaluated and compared the clinical performance of two HBV DNA assays based on different technologies: the RealArt HBV PCR Kit (Abbott HBV DNA PCR kit, real-time polymerase chain reaction assay, detection limit: 27 IU/mL) and the VERSANT bDNA 3.0 assay (Bayer, branched DNA signal amplification assay, detection limit: 357 IU/mL). Serum levels of HBV DNA in 173 chronic HBV carriers were determined using both the RealArt HBV PCR Kit and the VERSANT bDNA 3.0 test. Of the 173 samples analyzed for baseline viral load detection, HBV DNA was quantifiable in 147 patients (82.1%) by the RealArt HBV PCR Kit, which was significantly higher than the 92 (53.2%) samples quantified by the VERSANT bDNA 3.0 assay. A total of 86 (49.7%) samples were quantifiable by both assays, whereas 25 (14.5%) were below the detection limit of both assays. The HBV DNA quantification values measured by the RealArt HBV PCR Kit and the VERSANT bDNA 3.0 assay were positively correlated (Spearman's rank correlation coefficient r = 0.932, p < 0.001). On average, the results derived from the RealArt HBV PCR Kit were 0.67 log lower than those of the VERSANT bDNA 3.0 assay. HBV DNA concentrations were significantly higher in 63 HBV e antigen (HBeAg)-seropositive patients than in 110 HBeAg-seronegative patients (5.42 +/- 2.34 logs vs. 3.21 +/- 2.27 logs, p < 0.001). The RealArt HBV PCR Kit is more sensitive and has a wider dynamic range than the VERSANT bDNA 3.0 assay in the clinical setting of chronic hepatitis B patients. The sensitivity and wide dynamic range of the PCR assay allow optimal monitoring and timely adaptation of antiviral therapy. Nevertheless, the HBV DNA values measured by the RealArt HBV PCR Kit and the VERSANT bDNA 3.0 assay were significantly correlated.
Chen, Xi; Chen, Zehua; Li, Zhengya; Zhao, Chen; Zeng, Yuxiao; Zou, Ting; Fu, Caiyun; Liu, Xiaoli; Xu, Haiwei; Yin, Zheng Qin
2016-12-30
Despite diverse pathogenesis, the common pathological change observed in age-related macular degeneration and in most hereditary retinal degeneration (RD) diseases is photoreceptor loss. Photoreceptor replacement by cell transplantation may be a feasible treatment for RD. The major obstacles to clinical translation of stem cell-based cell therapy in RD remain the difficulty of obtaining sufficient quantities of appropriate and safe donor cells and the poor integration of grafted stem cell-derived photoreceptors into the remaining retinal circuitry. Eye-wall c-kit + /stage-specific embryonic antigen 1 (SSEA1) - cells were isolated via fluorescence-activated cell sorting, and their self-renewal and differentiation potential were detected by immunochemistry and flow cytometry in vitro. After labeling with quantum nanocrystal dots and transplantation into the subretinal space of rd1 RD mice, differentiation and synapse formation by daughter cells of the eye-wall c-kit + /SSEA1 - cells were evaluated by immunochemistry and western blotting. Morphological changes of the inner retina of rd1 mice after cell transplantation were demonstrated by immunochemistry. Retinal function of rd1 mice that received cell grafts was tested via flash electroretinograms and the light/dark transition test. Eye-wall c-kit + /SSEA1 - cells were self-renewing and clonogenic, and they retained their proliferative potential through more than 20 passages. Additionally, eye-wall c-kit + /SSEA1 - cells were capable of differentiating into multiple retinal cell types including photoreceptors, bipolar cells, horizontal cells, amacrine cells, Müller cells, and retinal pigment epithelium cells and of transdifferentiating into smooth muscle cells and endothelial cells in vitro. The levels of synaptophysin and postsynaptic density-95 in the retinas of eye-wall c-kit + /SSEA1 - cell-transplanted rd1 mice were significantly increased at 4 weeks post transplantation. The c-kit + /SSEA1 - cells were capable of differentiating into functional photoreceptors that formed new synaptic connections with recipient retinas in rd1 mice. Transplantation also partially corrected the abnormalities of inner retina of rd1 mice. At 4 and 8 weeks post transplantation, the rd1 mice that received c-kit + /SSEA1 - cells showed significant increases in a-wave and b-wave amplitude and the percentage of time spent in the dark area. Grafted c-kit + /SSEA1 - cells restored the retinal function of rd1 mice via regulating neural plasticity and forming new graft-to-host synapses.
Hazar, Muhsin; Otag, Aynur; Otag, Ilhan; Sezen, Mehmet; Sever, Ozan
2014-11-04
Exercise results in oxidative enzyme increase and micro-injuries in skeletal muscles. The aim of this study was to investigate the effect of maximal aerobic exercise on serum muscle enzymes in professional field hockey players. This study aims to determine the effect of increasing maximal aerobic exercise on creatine kinase (CK), creatine kinase-MB (CK-MB), aspartate aminotransferase (AST) and alanine aminotransferase (ALT) serum levels. 31 young professional field hockey players (13 female and 18 male players) volunteered for this study. All participants underwent the shuttle run test. Blood samples were taken from each participant before the shuttle run test. Post test blood samples were taken immediately after exercise and one hour after respectively. Pre and post test CK, CK-MB, AST and ALT values were measured by means of auto analyzer using original kits. The acute post test measure of the CK level increased in male (p=0.002) and female (p=0.00) sportsmen. CK-MB values obtained one hour after the exercise was lower than those before the exercise in males (p=0.02). In females (p=0.017) and males (p=0.05) AST activity significantly increased immediately after exercise and decreased to resting activity 1 h recovery. ALT significantly increased immediately after exercise in female (p=0.03) and male (p=0.00) athletes and after 1 h recovery ALT activities decreased below resting values. The timing and severity of exercise used in our study increased CK values, decreased CK-MB values and AST, ALT values increased in female and male field hockey players.
Shen, Cheng-Cheng; Chen, Bing; Gu, Jian-Teng; Ning, Jiao-Lin; Zeng, Jing; Yi, Bin; Lu, Kai-Zhi
2018-03-01
Recent studies have shown that pulmonary angiogenesis is an important pathological process in the development of hepatopulmonary syndrome (HPS), and growing evidence has indicated that Stromal cell-derived factor 1/C-X-C chemokine receptor type 4 (SDF-1/CXCR4) axis is involved in pulmonary vascular disease by mediating the accumulation of c-kit+ cells. This study aimed to test the effect of AMD3100, an antagonist of CXCR4, in HPS pulmonary angiogenesis. Common bile duct ligation (CBDL) rats were used as experimental HPS model and were treated with AMD3100 (1.25mg/kg/day, i.p.) or 0.9% saline for 3weeks. The sham rats underwent common bile duct exposure without ligation. The c-kit+ cells accounts and its angiogenic-related functions, prosurvival signals, pulmonary angiogenesis and arterial oxygenation were analysed in these groups. Our results showed that pulmonary SDF-1/CXCR4, Akt, Erk and VEGF/VEGFR2 were significantly activated in CBDL rats, and the numbers of circulating and pulmonary c-kit+ cells were increased in CBDL rats compared with control rats. Additionally, the angiogenic-related functions of c-kit+ cells and pulmonary microvessel counts were also elevated in CBDL rats. CXCR4 inhibition reduced pulmonary c-kit+ cells and microvessel counts and improved arterial oxygenation within 3weeks in CBDL rats. The pulmonary prosurvival signals and pro-angiogenic activity of c-kit+ cells were also down-regulated in AMD3100-treated rats. In conclusion, AMD3100 treatment attenuated pulmonary angiogenesis in CBDL rats and prevented the development of HPS via reductions in pulmonary c-kit+ cells and inhibition of the prosurvival signals. Our study provides new insights in HPS treatment. Copyright © 2017. Published by Elsevier B.V.
A Frameshift Mutation in KIT is Associated with White Spotting in the Arabian Camel.
Holl, Heather; Isaza, Ramiro; Mohamoud, Yasmin; Ahmed, Ayeda; Almathen, Faisal; Youcef, Cherifi; Gaouar, Semir; Antczak, Douglas F; Brooks, Samantha
2017-03-09
While the typical Arabian camel is characterized by a single colored coat, there are rare populations with white spotting patterns. White spotting coat patterns are found in virtually all domesticated species, but are rare in wild species. Theories suggest that white spotting is linked to the domestication process, and is occasionally associated with health disorders. Though mutations have been found in a diverse array of species, fewer than 30 genes have been associated with spotting patterns, thus providing a key set of candidate genes for the Arabian camel. We obtained 26 spotted camels and 24 solid controls for candidate gene analysis. One spotted and eight solid camels were whole genome sequenced as part of a separate project. The spotted camel was heterozygous for a frameshift deletion in KIT (c.1842delG, named KITW1 for White spotting 1), whereas all other camels were wild-type (KIT+/KIT+). No additional mutations unique to the spotted camel were detected in the EDNRB, EDN3, SOX10, KITLG, PDGFRA, MITF, and PAX3 candidate white spotting genes. Sanger sequencing of the study population identified an additional five kITW1/KIT+ spotted camels. The frameshift results in a premature stop codon five amino acids downstream, thus terminating KIT at the tyrosine kinase domain. An additional 13 spotted camels tested KIT+/KIT+, but due to phenotypic differences when compared to the KITW1/KIT+ camels, they likely represent an independent mutation. Our study suggests that there are at least two causes of white spotting in the Arabian camel, the newly described KITW1 allele and an uncharacterized mutation.
ERIC Educational Resources Information Center
Schwerin, Alan
1994-01-01
Describes procedures for a hands-on activity for students that involves the construction of radio-controlled model sailplane (or glider) kits, exposure to basic aerodynamic theory and concepts, and some flight school on a midsized field. (ZWH)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Doebber, I.; Dean, J.; Dominick, J.
2014-03-01
As part of its overall strategy to meet its energy goals, the Naval Facilities Engineering Command (NAVFAC) partnered with U.S. Department of Energy's (DOE) National Renewable Energy Laboratory (NREL) to rapidly demonstrate and deploy cost-effective renewable energy and energy efficiency technologies. This was one of several demonstrations of new and underutilized commercial energy efficiency technologies. The consistent year-round demand for air conditioning and dehumidification in Hawaii provides an advantageous demonstration location for advanced rooftop control (ARC) retrofit kits to packaged rooftop units (RTUs). This report summarizes the field demonstration of ARCs installed on nine RTUs serving a 70,000-ft 2 exchangemore » store (large retail) and two RTUs, each serving small office buildings located on Joint Base Pearl Harbor-Hickam (JBPHH).« less
Immunodiagnosis of toxocarosis in humans: evaluation of a new enzyme-linked immunosorbent assay kit.
Jacquier, P; Gottstein, B; Stingelin, Y; Eckert, J
1991-01-01
Excretory/secretory (E/S) antigen derived from second-stage larvae of Toxocara canis maintained in defined medium in vitro has been well established worldwide for the immunodiagnosis of human toxocarosis by enzyme-linked immunosorbent assay. Such an enzyme-linked immunosorbent assay, based on the detection of human anti-T. canis (E/S antigen) serum immunoglobulin G, has recently been commercialized by Biokema-Affinity Products (Crissier-Lausanne, Switzerland). This commercial test kit was evaluated with regard to its application in a routine diagnostic laboratory and the reliability of the results. Of 78 patients with suspected clinical toxocarosis, 71 had anti-T. canis antibodies (positive serological result) corresponding to a diagnostic sensitivity of 91%; 14% of serum samples (n = 199) from patients with protozoan or with helminthic infections also showed positive reactions mainly related to infections with Trichinella, Strongyloides, and Fasciola species. An epidemiological study with 1,000 serum samples from randomly selected healthy blood donors and children in Switzerland demonstrated a seroprevalence of 2.7%. The test kit under evaluation had an overall diagnostic sensitivity of 91% and a relative specificity of 86%, the latter being related to some protozoan and helminthic infections. Because of the scarcity of such infections, potential cross-reactivity does not play a major role under the conditions found in the middle part of Europe. In conclusion, the application of the test kit provided for use in this study can be recommended for routine diagnostic use. PMID:1774303
Fox, J C; Jordan, H E; Kocan, K M; George, T J; Mullins, S T; Barnett, C E; Glenn, B L; Cowell, R L
1986-03-01
Current methods and commercial test systems for the diagnosis of parasitic infections in both animals and humans are reviewed. Lists of test kits and their manufacturers are provided along with ordering information: the only commercially available test kits are for the diagnosis of toxoplasmosis in humans or animals and dirofilariasis (heartworm) in dogs. A partial list of diagnostic laboratories and the parasite tests they perform is also provided. Complete lists of diagnostic tests that could be obtained in the private sector are not available but would be useful. Two microfluorometric solid-phase assay systems are reviewed, and adaptations to custom assays for several kinds of parasites are briefly described. User problems in performing tests and interpreting results are stressed with emphasis placed on diagnosis of dirofilariasis in dogs. False-positive serology in dogs without heartworms and negative antibody responses in micro-filariae-positive animals are discussed with respect to proper interpretation of results.
Japhet, Margaret Oluwatoyin; Adewumi, Moses Olubusuyi; Adesina, Olufisayo Adeyemi; Donbraye, Emmanuel
2016-01-01
Blood transfusion service centers in Nigeria screen donated blood for markers of HIV infection using antibody- (Ab) based rapid test and in some centers, positives are re-tested using Ab-based ELISA. Paucity of data exists on p24 antigen prevalence among HIV Ab-negative donors in Nigeria. This study aims at detecting HIV p24 antigen among prospective blood donors in Osun State, Nigeria. Prospective blood donors negative for HIV antibodies using Determine test kit were re-tested using BIORAD GENSCREEN Ultra Ag-Ab ELISA kit, a fourth-generation ELISA kit that detects HIV antibodies/p24 antigen. Of the 169 HIV Ab-negative prospective donors, 10 (5.9%) were positive for HIV p24 antigen and 70% (7/10) of them were in the age range 18-30 years. Results of this study show that blood transfusion is still one of the major routes of HIV transmission in Nigeria and a higher proportion is among youth. Inclusion of p24 antigen testing into the blood donor screening will help reduce transfusion associated HIV in Nigeria if Nucleic Acid Testing (NAT) of all blood donor samples is not affordable; also, HIV enlightenment programs tailored toward youth may help reduce this rate among donors since more young people donate blood in low/middle-income countries than in high-income countries.
Schnyder, Manuela; Deplazes, Peter
2012-11-13
Dirofilaria immitis and Angiostrongylus vasorum are both important potentially fatal canine nematodes with overlapping endemic areas, especially in Europe. The preadult and adult stages of both species are living in the Arteria pulmonalis and the right heart, and diagnostically detectable circulating parasite antigens have been demonstrated for both species. For the detection of D. immitis infections, a variety of commercial tests have been developed, however, they have not been evaluated for cross-reactions against circulating antigens of A. vasorum. In this study, potential cross-reactions of sera from 16 dogs, which were experimentally infected with A. vasorum and which had circulating antigens as confirmed by a species-specific ELISA, were evaluated for the detection of A. vasorum antigen in six commercially available D. immitis test kits. In three fast tests (Witness® Dirofilaria, SensPERT® Canine Heartworm, SNAP® 4Dx® Plus), all sera were negative. One fast membrane ELISA (SNAP® HTWM RT Test) was positive with four sera (25%), and one serum delivered a non-valid result twice. In the PetChek® HTWM PF Test, depending on the interpretation protocol, 5 or 8 dogs (31.2 - 50%) were positive. With the DiroCHEK®-ELISA, a single A. vasorum-infected dog (6.2%) tested positive. Due to potential cross-reactions with A. vasorum in commercially available test kits for the detection of D. immitis antigen, the simultaneous use of highly specific diagnostic methods for the differentiation of these two canine heart worms is recommended.
c-KIT receptor expression is strictly associated with the biological behaviour of thyroid nodules
2012-01-01
Background A large amount of information has been collected on the molecular tumorigenesis of thyroid cancer. A low expression of c-KIT gene has been reported during the transformation of normal thyroid epithelium to papillary carcinoma suggesting a possible role of the gene in the differentiation of thyroid tissue rather than in the proliferation. The initial presentation of thyroid carcinoma is through a nodule and the best way nowadays to evaluate it is by fine-needle aspiration (FNA). However many thyroid FNAs are not definitively benign or malignant, yielding an indeterminate or suspicious diagnosis which ranges from 10 to 25% of FNAs. BRAF mutational analysis is commonly used to assess the malignancy of thyroid nodules but unfortunately it still leaves indeterminate diagnoses. The development of molecular initial diagnostic tests for evaluating a thyroid nodule is needed in order to define optimal surgical approach for patients with uncertain diagnosis pre- and intra-operatively. Methods In this study we extracted RNA from 82 FNA smears, 46 malignant and 36 benign at the histology, in order to evaluate by quantitative Real Time PCR the expression levels of c-KIT gene. Results We have found a highly preferential decrease rather than increase in transcript of c-KIT in malignant thyroid lesions compared to the benign ones. To explore the diagnostic utility of c-KIT expression in thyroid nodules, its expression values were divided in four arbitrarily defined classes, with class I characterized by the complete silencing of the gene. Class I and IV represented the two most informative groups, with 100% of the samples found malignant or benign respectively. The molecular analysis was proven by ROC (receiver operating characteristic) analysis to be highly specific and sensitive improving the cytological diagnostic accuracy of 15%. Conclusion We propose the use of BRAF test (after uncertain cytological diagnosis) to assess the malignancy of thyroid nodules at first, then the use of the c-KIT expression to ultimately assess the diagnosis of the nodules that otherwise would remain suspicious. The c-KIT expression-based classification is highly accurate and may provide a tool to overcome the difficulties in today's preoperative diagnosis of thyroid suspicious malignancies. PMID:22233760
Xiaodong, Sun; Tambo, Ernest; Chun, Wei; Zhibin, Cheng; Yan, Deng; Jian, Wang; Jiazhi, Wang; Xiaonong, Zhou
2013-01-07
Rapid diagnostic test (RDT) is becoming an alternative way of establishing quickly the diagnosis of malaria infections, by detecting specific malaria antigens in suspected patients' blood between the China-Myanmar endemic borders areas, towards achieving the National Malaria Elimination programme by 2020. The objective of this study is to evaluate the performance of CareStart™ Malaria Pf/Pan RDT kit for the diagnosis of malaria infections in suspected patients. Blood examination by microscopy was taken as gold standard to evaluate CareStart™ kit's sensitivity, specificity and predictive value and corrected with PCR assay. Overall 126 of 241 (52.28%) malaria cases were detected by microscopy compared to 115 of 241(47.72%) CareStart™ kit and 128 of 241 (53.11%) PCR corrected assay. CareStart™ kit's sensitivity and specificity for the diagnosis of malaria were 89.68% and 98.26% respectively, compared to standard microscopy, whereas the sensitivity and specificity for falciparum malaria were 88.52% and 98.26%, and for vivax malaria: 90.77% and 100%. The CareStart™ positive predictive values were 98.26% (93.88-99.52%, 95% CI) compared to 100% (96.77-100%, 95% CI) for PCR-corrected, and the negative predictive values of 89.68% (83.15-93.87%, 95% CI) were the same in microscopy as PCR-corrected. The diagnostic accuracy of CareStart™ kit versus microscopy and PCR were 93.78% (89.99-96.19%, 95% CI) and 94.61% (90.99-96.82%, 95% CI) respectively. The likelihood of diagnostic of malaria positive was almost similar between microscopy and CareStart™ kit, with an entropy reduction of 60.0% compared to a weak likelihood of misdiagnosis of 0.10 (0.09-0.12, 95% CI), with an entropy reduction of 36.01%. The accuracy of CareStart™ kit is comparable to gold standard microscopy in these areas, it is easy to perform and suitable for cross-border diagnosis and monitoring of local or imported malaria patterns by any local health staff in endemic remotes.
Shrestha, Nabin K.; Tuohy, Marion J.; Padmanabhan, Ravindran A.; Hall, Gerri S.; Procop, Gary W.
2005-01-01
We evaluated the Roche LightCycler Staphylococcus MGRADE kits to differentiate between Staphylococcus aureus and coagulase-negative staphylococci in blood cultures growing clusters of gram-positive cocci. Testing 100 bottles (36 containing S. aureus), the assay was 100% sensitive and 98.44% specific for S. aureus and 100% sensitive and specific for coagulase-negative staphylococci. PMID:16333115
Shrestha, Nabin K; Tuohy, Marion J; Padmanabhan, Ravindran A; Hall, Gerri S; Procop, Gary W
2005-12-01
We evaluated the Roche LightCycler Staphylococcus M(GRADE) kits to differentiate between Staphylococcus aureus and coagulase-negative staphylococci in blood cultures growing clusters of gram-positive cocci. Testing 100 bottles (36 containing S. aureus), the assay was 100% sensitive and 98.44% specific for S. aureus and 100% sensitive and specific for coagulase-negative staphylococci.
Mason, Kathleen L; Gonzalez, Michael V; Chung, Chungwon; Mousel, Michelle R; White, Stephen N; Taylor, Joshua B; Scoles, Glen A
2017-09-01
An accurate and simple-to-perform new version of a competitive ELISA (cELISA) kit that became commercially available in 2015 for testing of cattle for antibody to Anaplasma marginale was validated for detection of Anaplasma ovis antibody in domestic sheep. True positives and negatives were identified using nested PCR (nPCR) as the gold standard. Negative bovine control sera supplied with the kit were used to calculate % inhibition (%I), designated bovine control ELISA (BcELISA), and this was compared to %I calculated from negative ovine sera derived from hand-raised, pathogen-free sheep, designated ovine control ELISA (OcELISA). The receiver operating characteristics area under the curve was 1.0 with a p value <0.001 regardless of the source of the control sera. The cutoff values for negative BcELISA and OcELISA were <30%I and <27%I, respectively. Our work confirmed that this Anaplasma antibody cELISA kit version 2 can be used with the serum controls supplied in the kit to test for A. ovis antibody in domestic sheep. Furthermore, this work confirmed the historically high infection prevalence (>93%) at the U.S. Sheep Experiment Station (Dubois, Idaho), in spite of efforts to reduce the possibility for iatrogenic transmission there, suggesting high levels of tick-borne transmission.
Quality and use of consumer information provided with home test kits: room for improvement.
Grispen, Janaica E J; Ickenroth, Martine H P; de Vries, Nanne K; van der Weijden, Trudy; Ronda, Gaby
2014-10-01
Diagnostic self-tests (tests on body materials that are initiated by consumers with the aim of diagnosing a disorder or risk factor) are becoming increasingly available. Although the pros and cons of self-testing are currently not clear, it is an existing phenomenon that is likely to gain further popularity. To examine consumers' use of and needs for information about self-testing, and to assess the quality of consumer information provided with home test kits, as perceived by consumers and as assessed using a checklist of quality criteria. A cross-sectional Internet survey among 305 self-testers assessed their use of and needs for information and their perception of the quality of consumer information provided with self-test kits. A meta-search engine was used to identify Dutch and English consumer information for home diagnostic tests available online at the time of the study. The quality of this consumer information was evaluated using a checklist of quality criteria. The consumers' information needs were in line with the most frequently used information, and the information was perceived as being of moderate to good quality. The information was mostly in agreement with clinical practice guidelines, although information on reliability and follow-up behaviour was limited. Approximately half of the instruction leaflets did not include information on the target group of the test. Although generally of moderate to good quality, some aspects of the information provided were in many cases insufficient. European legislation concerning self-tests and accompanying information needs to be adapted and adhered to more closely. © 2012 John Wiley & Sons Ltd.
TECHNOLOGIES FOR MONITORING AND MEASUREMENT ...
A demonstration of technologies for determining the presence of dioxin and dioxin-like compounds in soil and sediment was conducted under EPA's Superfund Innovative Technology Evaluation Program in Saginaw, Michigan in April 2004. This report describes the performance evaluation of the Abraxis LLC Coplanar PCB Enzyme-Linked Immunosorbent Assay (ELISA) kit. The kit is an immunoassay technique that reports the total toxicity equivalents (TEQ) of polychlorinated biphenyls (PCBs). The technology results were compared to high resolution mass spectrometry TEQ results generated using EPA Method 1668A.Abraxis generally reported data that were higher than the reference laboratory TEQPCB values, with the exception of ultra-high level PCB samples [> 10,000 picogram/gram (pg/g) TEQ] where Abraxis reported values lower than the reference method. The technologys estimated MDL was 6 to 31 pg/g TEQPCB. Results from this demonstration suggest that the Abraxis kit could be an effective screening tool for screening sample concentrations above and below 50 pg/g TEQPCB, particularly considering that the cost ($22,668 vs. $184,449) and the time to analyze the 209 demonstration samples were significantly less than those of the reference laboratory. The objective of this program is to promote the acceptance and use of innovative field technologies by providing well-documented performance and cost data obtained from field demonstrations.
Roh, Eun-Youn; Song, Eun-Young; Chang, Jee-Young; Yoon, Jong-Hyun; Shin, Sue
2016-08-01
The performance of a new intermediate-resolution method using a PCR-Luminex platform and LABType® SSO A, B DRB1 kits as an HLA typing method for the cord blood (CB) registry of the Korean population was investigated. A total of 1,413 cord blood units (CBUs) were enrolled - 1,382 from Koreans and 31 from non-Koreans or mixed-ancestry individuals. HLA-A, -B, and -DRB1 typing was performed using the LABType® SSO typing kits. HLA typing with the DNA method and 2-digit results are mandatory for the public CB bank in Korea according to the "CB Act." The proportions of ambiguous results in the 2-digit assignment were 14.6% (206/1,413) and 14.8% (205/ 1,382) among the total subjects and the Korean donors, respectively. In the 2-digit resolution, 3 different HLA-A types (69 CBUs), 31 HLA-B types (124 CBUs), and 3 HLA-DRB1 types (13 CBUs) showed ambiguous results. The 'most probable type' to the ambiguous results based on the reported Korean HLA allele frequencies were able to be assigned. The most probable results were 100% consistent with the confirmed types as determined by the HD kits (DRB1) and additional PCR-SBT or PCR-SSP tests (A and B). Luminex technology is more automated and less labor intensive than the conventional SSO typing method, and the results are less affected by differences between inspectors. Although it is not satisfactory as a sole confirmation test and cannot be used as a replacement for the PCR-SBT test, the combination of Luminex technology with LABType® SSO kits and population frequency data provides a proper typing platform that can be used as a qualifying test for CB registries.
Hoyos, J; Maté, T; Indave, B I; Agustí, C; Chanos, S; Pichon, F; Kuske, M; Cigan, B; Fuertes, R; Ooms, L; Stefanescu, R; Cabeza de Vaca, C; Arranz, B; de la Fuente, L; Belza, M J
2018-02-01
To describe the knowledge as well as current and potential use of self-sampling kits among men who have sex with men (MSM) and to analyse their preferred biological sample and result communication method. We analyse data of MSM of HIV negative or unknown serostatus from an online survey conducted in eight countries (Belgium, Denmark, Germany, Greece, Portugal, Romania, Slovenia and Spain) between April and December 2016. It was advertised mainly in gay dating websites. We conduct a descriptive analysis of the main characteristics of the participants, and present data on indicators of knowledge, use and potential use of HIV self-sampling as well as their preferences regarding blood or saliva sample and face or non-face-to-face result communication by country of residence. A total of 8.226 participants of HIV negative or unknown serostatus were included in the analysis. Overall, 25.5% of participants knew about self-sampling (range: 18.8-47.2%) and 1.1% had used it in the past (range: 0.3-8.9%). Potential use was high, with 66.6% of all participants reporting that they would have already used it if available in the past (range: 62.1-82.1%). Most (78.6%) reported that they would prefer using a blood-based kit, and receiving the result of the test through a non-face-to-face-method (70.8%), even in the case of receiving a reactive result. The high potential use reported by MSM recruited in eight different European countries suggests that self-sampling kits are a highly acceptable testing methodology that could contribute to the promotion of HIV testing in this population. © 2018 British HIV Association.
Kramer, Benedikt; Kneissle, Marcel; Birk, Richard; Rotter, Nicole; Aderhold, Christoph
2018-05-01
Therapeutic options of locally advanced or metastatic head and neck squamous cell carcinoma (HNSCC) are limited. Src and cKIT are key protein regulators for local tumor progression. The aim of the study was to investigate the therapeutic potential of targeted therapies in human squamous cell carcinoma (HNSCC) in vitro. Therefore, the influence of the selective tyrosine kinase inhibitors niotinib, dasatinib, erlotinib, gefitinib and afatinib on Src and cKIT expression in Human papilloma virus (HPV)-positive and HPV-negative squamous cancer cells (SCC) was analyzed in vitro. ELISA was performed to evaluate the expression of Src and cKIT under the influence of nilotinib, dasatinib, erlotinib, gefitinib and afatinib (10 μmol/l) in HPV-negative and HPV-positive SCC (24-96 h of incubation). Gefitinib significantly increased cKIT expression in HPV-positive and HPV-negative cells whereas nilotinib and afatinib decreased cKIT expression in HPV-positive SCC. The influence of tyrosine kinase inhibitors in HPV-negative SCC was marginal. Surprisingly, Src expression was significantly increased by all tested tyrosine kinase inhibitors in HPV-positive SCC. The results revealed beneficial and unexpected information concerning the interaction of selective tyrosine kinase inhibitors and the tumor biology of HNSCC. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.
Schorling, Stefan; Schalasta, Gunnar; Enders, Gisela; Zauke, Michael
2004-01-01
The COBAS AmpliPrep instrument (Roche Diagnostics GmbH, D-68305 Mannheim, Germany) automates the entire sample preparation process of nucleic acid isolation from serum or plasma for polymerase chain reaction analysis. We report the analytical performance of the LightCycler Parvovirus B19 Quantification Kit (Roche Diagnostics) using nucleic acids isolated with the COBAS AmpliPrep instrument. Nucleic acids were extracted using the Total Nucleic Acid Isolation Kit (Roche Diagnostics) and amplified with the LightCycler Parvovirus B19 Quantification Kit. The kit combination processes 72 samples per 8-hour shift. The lower detection limit is 234 IU/ml at a 95% hit-rate, linear range approximately 104-1010 IU/ml, and overall precision 16 to 40%. Relative sensitivity and specificity in routine samples from pregnant women are 100% and 93%, respectively. Identification of a persistent parvovirus B19-infected individual by the polymerase chain reaction among 51 anti-parvovirus B19 IgM-negative samples underlines the importance of additional nucleic acid testing in pregnancy and its superiority to serology in identifying the risk of parvovirus B19 transmission via blood or blood products. Combination of the Total Nucleic Acid Isolation Kit on the COBAS AmpliPrep instrument with the LightCycler Parvovirus B19 Quantification Kit provides a reliable and time-saving tool for sensitive and accurate detection of parvovirus B19 DNA. PMID:14736825
PCP IMMUMOASSAY TECHNOLOGIES - INNOVATIVE TECHNOLOGY EVALUATION REPORT
Three enzyme-linked immunosorbent assay technologies for pentachlorophenol (PCP) testing in soil and water were evaluated. Penta RISc Test Systems (formerly ENSYS, Inc.), EnviroGard™ PCP Immunoassay Test Kit (Millipore Corp.), and Pentachlorophenol RaPID Assay (formerly Ohmicron ...
Sensitivity or artifact? -- IQ Toxicity Test -- effluent values
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hayes, K.R.; Novotny, A.N.; Batista, N.
1995-12-31
Several complex effluents were DAPHNIA MAGNA IQ TOXICITY TESTED -- (1.25 hours) and conventionally tested with Daphnia magna (48 hours). In many samples the IQ Technology yielded low EC50 values while the 48 hour exposures yielded no acute toxicity. Possible explanations have been suggested for this occurrence such as: genotoxicity, mutagenicity, substrate interference, and enzyme satiation. To identify the causative agent(s) of this response a Toxicity Identification Evaluation was performed on one of the samples. To define the nature of the response, THE SOS-CHROMOTEST KIT and THE MUTA-CHROMOPLATE KIT were utilized to characterize genotoxicity and mutagenicity respectively. The sample didmore » not test positive for genotoxicity but tested positive for mutagenicity only after activation with S9 enzymes, suggesting the presence of promutagens. Additional work needs to be performed to correlate IQ TOXICITY TEST sensitivity with positive MUTA-CHROMOPLATE response.« less
Disposable Collection Kit for Rapid and Reliable Collection of Saliva
Yamaguchi, Masaki; Tezuka, Yuki; Takeda, Kazunori; Shetty, Vivek
2015-01-01
Objectives To describe and evaluate disposable saliva collection kit for rapid, reliable, and reproducible collection of saliva samples. Methods The saliva collection kit comprised of a saliva absorbent swab and an extractor unit was used to retrieve whole saliva samples from 10 subjects. The accuracy and precision of the extracted volumes (3, 10, and 30 μl) were compared to similar volumes drawn from control samples obtained by passive drool. Additionally, the impact of kit collection method on subsequent immunoassay results was verified by assessing salivary cortisol levels in the samples and comparing them to controls. Results The recovered volumes for the whole saliva samples were 3.85 ± 0.28, 10.79 ± 0.95, and 31.18 ± 1.72 μl, respectively (CV = 8.76%) and 2.91 ± 0.19, 9.75 ± 0.43, and 29.64 ± 0.91 μl, respectively, (CV = 6.36%) for the controls. There was a close correspondence between the salivary cortisol levels from the saliva samples obtained by the collection kit and the controls (R2 > 0.96). Conclusions The disposable saliva collection kit allows accurate and repeatable collection of fixed amounts of whole saliva and does not interfere with subsequent measurements of salivary cortisol. The simple collection process, lack of elaborate specimen recovery steps, and the short turnaround time (<3 min) should render the kit attractive to test subjects and researchers alike. Am. J. Hum. Biol. 27:720–723, 2015. © 2015 The Authors American Journal of Human Biology Published by Wiley Periodicals, Inc. PMID:25754371
Ahn, Sang Hoon; Chun, Ji-Yong; Shin, Soo-Kyung; Park, Jun Yong; Yoo, Wangdon; Hong, Sun Pyo; Kim, Soo-Ok; Han, Kwang-Hyub
2013-12-01
Molecular diagnostic methods have enabled the rapid diagnosis of drug-resistant mutations in hepatitis B virus (HBV) and have reduced both unnecessary therapeutic interventions and medical costs. In this study we evaluated the analytical and clinical performances of the HepB Typer-Entecavir kit (GeneMatrix, Korea) in detecting entecavir-resistance-associated mutations. The HepB Typer-Entecavir kit was evaluated for its limit of detection, interference, cross-reactivity, and precision using HBV reference standards made by diluting high-titer viral stocks in HBV-negative human serum. The performance of the HepB Typer-Entecavir kit for detecting mutations related to entecavir resistance was compared with direct sequencing for 396 clinical samples from 108 patients. Using the reference standards, the detection limit of the HepB Typer-Entecavir kit was found to be as low as 500 copies/mL. No cross-reactivity was observed, and elevated levels of various interfering substances did not adversely affect its analytical performance. The precision test conducted by repetitive analysis of 2,400 replicates with reference standards at various concentrations showed 99.9% agreement (2398/2400). The overall concordance rate between the HepB Typer-Entecavir kit and direct sequencing assays in 396 clinical samples was 99.5%. The HepB Typer-Entecavir kit showed high reliability and precision, and comparable sensitivity and specificity for detecting mutant virus populations in reference and clinical samples in comparison with direct sequencing. Therefore, this assay would be clinically useful in the diagnosis of entecavir-resistance-associated mutations in chronic hepatitis B.
Paternity testing in case of brother-sister incest.
Macan, Marijana; Uvodić, Petra; Botica, Vladimir
2003-06-01
We performed a paternity test in a case of incest between brother and sister. DNA from blood samples of the alleged parents and their two children was obtained with Chelex DNA extraction method and quantified with Applied Biosystems QuantiBlot quantitation kit. Polymerase chain reaction (PCR) amplification of DNA samples was performed with AmpFlSTR SGM Plus PCR amplification kit and GenePrint PowerPlex PCR amplification kit. The amplified products were separated and detected by using the Perkin Elmer's ABI PRISM trade mark 310 Genetic Analyser. DNA and data analysis of 17 loci and Amelogenin confirmed the suspicion of brother-sister incest. Since both children had inherited all of the obligate alleles from the alleged father, we could confirm with certainty of 99.999999% that the oldest brother in the family was the biological father of both children. Calculated data showed that even in a case of brother-sister incest, paternity could be proved by the analysis of Amelogenin and 17 DNA loci.
Comparison of Four Saliva Detection Methods to Identify Expectorated Blood Spatter.
Park, Hee-Yeon; Son, Bu-Nam; Seo, Young-Il; Lim, Si-Keun
2015-11-01
Blood spatter analysis is an important step for crime scene reconstruction. The presence of saliva in blood spatter could indicate expectorated blood which is difficult to distinguish from impact spatter. In this study, four saliva test methods (SALIgAE(®) , Phadebas(®) sheet, RSID(™) -Saliva kit, and starch gel diffusion) were compared to identify the best method for detecting expectorated blood spatter. The RSID(™) -Saliva kit showed the highest sensitivity even when saliva was mixed with blood, and was not inhibited by the presence of blood. The SALIgAE(®) test provided easy and rapid results, but the yellow color of a positive reaction was overwhelmed by the red color of the blood. The starch gel diffusion method and the Phadebas(®) sheet exhibited relatively low sensitivity and the assay took a long time. When using the RSID(™) -Saliva kit for identifying saliva in blood, results should be read within 10 min. © 2015 American Academy of Forensic Sciences.
Vaccine-induced HIV seropositivity/reactivity in noninfected HIV vaccine recipients.
Cooper, Cristine J; Metch, Barbara; Dragavon, Joan; Coombs, Robert W; Baden, Lindsey R
2010-07-21
Induction of protective anti-human immunodeficiency virus (HIV) immune responses is the goal of an HIV vaccine. However, this may cause a reactive result in routine HIV testing in the absence of HIV infection. To evaluate the frequency of vaccine-induced seropositivity/reactivity (VISP) in HIV vaccine trial participants. Three common US Food and Drug Administration-approved enzyme immunoassay (EIA) HIV antibody kits were used to determine VISP, and a routine diagnostic HIV algorithm was used to evaluate VISP frequency in healthy, HIV-seronegative adults who completed phase 1 (n = 25) and phase 2a (n = 2) vaccine trials conducted from 2000-2010 in the United States, South America, Thailand, and Africa. Vaccine-induced seropositivity/reactivity, defined as reactive on 1 or more EIA tests and either Western blot-negative or Western blot-indeterminate/atypical positive (profile consistent with vaccine product) and HIV-1-negative by nucleic acid testing. Among 2176 participants free of HIV infection who received a vaccine product, 908 (41.7%; 95% confidence interval [CI], 39.6%-43.8%) had VISP, but the occurrence of VISP varied substantially across different HIV vaccine product types: 399 of 460 (86.7%; 95% CI, 83.3%-89.7%) adenovirus 5 product recipients, 295 of 552 (53.4%; 95% CI, 49.2%-57.7%) recipients of poxvirus alone or as a boost, and 35 of 555 (6.3%; 95% CI, 4.4%-8.7%) of DNA-alone product recipients developed VISP. Overall, the highest proportion of VISP (891/2176 tested [40.9%]) occurred with the HIV 1/2 (rDNA) EIA kit compared with the rLAV EIA (150/700 tested [21.4%]), HIV-1 Plus O Microelisa System (193/1309 tested [14.7%]), and HIV 1/2 Peptide and HIV 1/2 Plus O (189/2150 tested [8.8%]) kits. Only 17 of the 908 participants (1.9%) with VISP tested nonreactive using the HIV 1/2 (rDNA) kit. All recipients of a glycoprotein 140 vaccine (n = 70) had VISP, with 94.3% testing reactive with all 3 EIA kits tested. Among 901 participants with VISP and a Western blot result, 92 (10.2%) had a positive Western blot result (displaying an atypical pattern consistent with vaccine product), and 592 (65.7%) had an indeterminate result. Only 8 participants with VISP received a vaccine not containing an envelope insert. The induction of VISP in HIV vaccine recipients is common, especially with vaccines containing both the HIV-1 envelope and group-specific core antigen gene proteins. Development and detection of VISP appear to be associated with the immunogenicity of the vaccine and the EIA assay used.
Investigator® HDplex (Qiagen) reference population database for forensic use in Argentina.
Martínez, Gustavo; Borosky, Alicia; Corach, Daniel; Llull, Cintia; Locarno, Laura; Lojo, Mercedes; Marino, Miguel; Miozzo, María Cecilia; Modesti, Nidia; Pacharoni, Carla; Pilili, Juan Pablo; Ramella, María Isabel; Sala, Andrea; Schaller, Cecilia; Vullo, Carlos; Toscanini, Ulises
2017-01-01
Currently, autosomal Short Tandem Repeat (STR) markers represent the method of election in forensic human identification. Commercial kits of most common use nowadays -e.g. PowerPlex ® Fusion, Promega Corp.; AmpFlSTR GlobalFiler, Thermofisher scientific; Investigator 24Plex QS,Qiagen-, allow the co-amplification of 23 highly polymorphic STR loci providing a high discrimination power in human identity testing. However, in complex kinship analysis and familial database searches involving distant relationships, additional DNA typing is often required in order to achieve well-founded conclusions. The recently developed kit Investigator ® HDplex (Qiagen) co-amplify twelve autosomal STRs markers (D7S1517, D3S1744, D12S391, D2S1360, D6S474, D4S2366, D8S1132, D5S2500, D18S51, D21S2055, D10S2325, SE33), nine of which are not present in the above mentioned kits, providing a set of efficient supplementary markers for human identification purposes. In this study we genotyped a sample of 980 individuals from urban areas of ten Argentinean provinces using the Investigator ® HDplex kit, aiming to provide forensic estimates for use in forensic casework and parentage testing in Argentina. We report reference allelic frequency databases for each of the provinces studied as well as for the combined samples. No deviation of Hardy-Weinberg equilibrium was observed. A reasonable discrimination capacity and power of exclusion was estimated which allowed predicting an acceptable forensic behavior of this kit, either to be used as the main STR panel for simple cases or as an auxiliary tool in complex cases. Additionally, population comparison tests showed that the studied samples are relatively homogeneous across the country for these STR set. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Martins, Cátia; Ferreira, Paulo Miguel; Carvalho, Raquel; Costa, Sandra Cristina; Farinha, Carlos; Azevedo, Luísa; Amorim, António; Oliveira, Manuela
2018-02-01
Obtaining a genetic profile from pieces of evidence collected at a crime scene is the primary objective of forensic laboratories. New procedures, methods, kits, software or equipment must be carefully evaluated and validated before its implementation. The constant development of new methodologies for DNA testing leads to a steady process of validation, which consists of demonstrating that the technology is robust, reproducible, and reliable throughout a defined range of conditions. The present work aims to internally validate two new retrotransposon-based kits (InnoQuant ® HY and InnoTyper ® 21), under the working conditions of the Laboratório de Polícia Científica da Polícia Judiciária (LPC-PJ). For the internal validation of InnoQuant ® HY and InnoTyper ® 21 sensitivity, repeatability, reproducibility, and mixture tests and a concordance study between these new kits and those currently in use at LPC-PJ (Quantifiler ® Duo and GlobalFiler™) were performed. The results obtained for sensitivity, repeatability, and reproducibility tests demonstrated that both InnoQuant ® HY and InnoTyper ® 21 are robust, reproducible, and reliable. The results of the concordance studies demonstrate that InnoQuant ® HY produced quantification results in nearly 29% more than Quantifiler ® Duo (indicating that this new kit is more effective in challenging samples), while the differences observed between InnoTyper ® 21 and GlobalFiler™ are not significant. Therefore, the utility of InnoTyper ® 21 has been proven, especially by the successful amplification of a greater number of complete genetic profiles (27 vs. 21). The results herein presented allowed the internal validation of both InnoQuant ® HY and InnoTyper ® 21, and their implementation in the LPC-PJ laboratory routine for the treatment of challenging samples. Copyright © 2017 Elsevier B.V. All rights reserved.
InstantLabs Listeria monocytogenes food safety kit. Performance tested method 051304.
Sharma, Neil; Bambusch, Lauren; Le, Thu; Morey, Amit
2014-01-01
The InstantLabs Listeria monocytogenes Food Safety Kit was validated against the International Organization for Standardization (ISO) reference method 11290-1 for the detection of Listeria monocytogenes and other Listeria species. The matrixes (stainless steel, sealed concrete, ice cream, whole milk, cheddar cheese, raw shrimp, hot dogs, deli turkey, and lettuce) were inoculated with approximately 1 CFU/test portion of L. monocytogenes to generate fractional positives (5-15) in 20 inoculated samples. Enrichments were also fractionally inoculated with L. grayii for side-by-side testing of the Listeria Species Food Safety Kit. Stainless steel and sealed concrete samples were validated using 4 x 4" and 1 x 1 " test areas, respectively, and enriched in Buffered Listeria Enrichment Broth (BLEB) at 35 +/- 1degreesC for 22-28 h. All food samples were tested at 25 g and enriched in BLEB at 35 +/- 1 degreesC for 24-28 h. All samples were confirmed using the ISO reference method, regardless of initial screen result. The InstantLabs test method performed as well as or better than the reference method for the detection of L. monocytogenes on stainless steel and sealed concrete and in ice cream, whole milk, cheddar cheese, raw shrimp, hot dogs, deli turkey, and lettuce. Inclusivity and exclusivity testing revealed no false negatives and no false positives among the 50 L. monocytogenes serovars and 30 non-L. monocytogenes species examined. The method was shown to be robust when the enrichment times, volumes for DNA extraction, and heat block times were varied.
Feleke, Daniel Getacher; Tarko, Shambel; Hadush, Haftom
2017-06-06
Rapid diagnostic tests (RDTs) are alternative methods for microscopy in the diagnosis of malaria in resource limited settings. Among commercially available RDTs, CareStart™ Malaria test was found to show reliable results. This study evaluated the performance of CareStart™ Malaria Combo test kit in Northwestern Tigray in Ethiopia. Blood samples were collected from 320 malaria-suspected patients at Mayani Hospital in Northwestern Tigray from December 2015 to March 2016. All blood samples were examined using both light microscopy and CareStart™ Malaria HRP2/pLDH Combo Test kit. Statistical analyses were performed using SPSS version 20. The overall parasite positivity using light microscopy and CareStart™ RDT was 41 (12.8%) and 43 (13.4%), respectively. The sensitivity and specificity of CareStart™ RDT, regardless of species, were found to be 95.4 and 99.3%, respectively. Furthermore, the sensitivity of CareStart™ RDT for Plasmodium falciparum or mixed infection and non-falciparum malaria parasites was 94.4 and 85.0%, respectively while the specificity was found to be 98.9 and 99.7%, respectively. The agreement between the two test methods was "excellent" with a kappa value of 0.92. CareStart™ RDT has very good sensitivity and specificity for malaria diagnosis. The test kit also has an excellent agreement with light microscopy. It is therefore useful in resource-limited areas where microscopy is not available.
Nardini, Roberto; Autorino, Gian Luca; Issel, Charles J; Cook, R Frank; Ricci, Ida; Frontoso, Raffaele; Rosone, Francesca; Scicluna, Maria Teresa
2017-04-14
ELISAs are known to have a higher diagnostic sensitivity than the agar gel immunodiffusion (AGID) when employed for serological diagnosis of equine infectious anaemia (EIA). For this purpose, an "in-house" and five commercial ELISAs available in Italy were assessed by the National Reference Centre for EIA for their analytic specificity (Sp); precocity, defined as capability of detecting first antibodies produced during a new infection; precision based on repeatability and reproducibility, estimated from the coefficient of variation (CV); accuracy, estimated from multiple K and relative Sp and sensitivity (Se). Two serum panels, positive for non-equine retroviruses and the most frequent equine viruses, were employed to measure analytic Sp. ELISA precocity was also compared to that of one "in-house" and three commercial AGID kits, employing a panel of sera, collected weekly from horses infected with modified EIA viruses. Precision and accuracy were defined using results of a panel containing positive and negative sera examined in an inter-laboratory trial with the participation of the ten Official Laboratories. Furthermore, a questionnaire was used to assess the appropriateness of each kit for routine use. Analytic Sp was 100%, while the 75th percentile of CVs for positive sera varied from 0.4% to 12.73% for repeatability and from 1.6% to 44.87% for reproducibility. Although CV of the negative serum was constantly high, its outcome was unaltered. Relative Se ranged from 98.2% to 100%, relative Sp was constantly 100% and multiple K ranged from 0.95 to 1. Precocity differed among the assays: three kits detected 4.8% and 42.9% positive samples on 21 days post infection (dpi), all assays detected positive samples on 28 dpi, between 47.6% and 95.2%. Precocity of ELISAs was superior to that of the AGIDs except for two assays. In view of the feedback obtained from the questionnaires, all kits were considered appropriate for routine use. All ELISAs having high Se and precocity are preferable as a screening test in EIA surveillance programmes to the AGID tests examined. These two tests can be incorporated in a serial diagnostic pathway to improve the efficacy of a surveillance plan.
Choko, Augustine Talumba; Kumwenda, Moses Kelly; Johnson, Cheryl Case; Sakala, Doreen Wongera; Chikalipo, Maria Chifuniro; Fielding, Katherine; Chikovore, Jeremiah; Desmond, Nicola; Corbett, Elizabeth Lucy
2017-06-26
In the era of ambitious HIV targets, novel HIV testing models are required for hard-to-reach groups such as men, who remain underserved by existing services. Pregnancy presents a unique opportunity for partners to test for HIV, as many pregnant women will attend antenatal care (ANC). We describe the views of pregnant women and their male partners on HIV self-test kits that are woman-delivered, alone or with an additional intervention. A formative qualitative study to inform the design of a multi-arm multi-stage cluster-randomized trial, comprised of six focus group discussions and 20 in-depth interviews, was conducted. ANC attendees were purposively sampled on the day of initial clinic visit, while men were recruited after obtaining their contact information from their female partners. Data were analysed using content analysis, and our interpretation is hypothetical as participants were not offered self-test kits. Providing HIV self-test kits to pregnant women to deliver to their male partners was highly acceptable to both women and men. Men preferred this approach compared with standard facility-based testing, as self-testing fits into their lifestyles which were characterized by extreme day-to-day economic pressures, including the need to raise money for food for their household daily. Men and women emphasized the need for careful communication before and after collection of the self-test kits in order to minimize the potential for intimate partner violence although physical violence was perceived as less likely to occur. Most men stated a preference to first self-test alone, followed by testing as a couple. Regarding interventions for optimizing linkage following self-testing, both men and women felt that a fixed financial incentive of approximately USD$2 would increase linkage. However, there were concerns that financial incentives of greater value may lead to multiple pregnancies and lack of child spacing. In this low-income setting, a lottery incentive was considered overly disappointing for those who receive nothing. Phone call reminders were preferred to short messaging service. Woman-delivered HIV self-testing through ANC was acceptable to pregnant women and their male partners. Feedback on additional linkage enablers will be used to alter pre-planned trial arms.
Cell-free synthetic biology for in vitro prototype engineering.
Moore, Simon J; MacDonald, James T; Freemont, Paul S
2017-06-15
Cell-free transcription-translation is an expanding field in synthetic biology as a rapid prototyping platform for blueprinting the design of synthetic biological devices. Exemplar efforts include translation of prototype designs into medical test kits for on-site identification of viruses (Zika and Ebola), while gene circuit cascades can be tested, debugged and re-designed within rapid turnover times. Coupled with mathematical modelling, this discipline lends itself towards the precision engineering of new synthetic life. The next stages of cell-free look set to unlock new microbial hosts that remain slow to engineer and unsuited to rapid iterative design cycles. It is hoped that the development of such systems will provide new tools to aid the transition from cell-free prototype designs to functioning synthetic genetic circuits and engineered natural product pathways in living cells. © 2017 The Author(s).
Battery operated preconcentration-assisted lateral flow assay.
Kim, Cheonjung; Yoo, Yong Kyoung; Han, Sung Il; Lee, Junwoo; Lee, Dohwan; Lee, Kyungjae; Hwang, Kyo Seon; Lee, Kyu Hyoung; Chung, Seok; Lee, Jeong Hoon
2017-07-11
Paper-based analytical devices (e.g. lateral flow assays) are highly advantageous as portable diagnostic systems owing to their low costs and ease of use. Because of their low sensitivity and detection limits for biomolecules, these devices have several limitations in applications for real-field diagnosis. Here, we demonstrate a paper-based preconcentration enhanced lateral flow assay using a commercial β-hCG-based test. Utilizing a simple 9 V battery operation with a low power consumption of approximately 81 μW, we acquire a 25-fold preconcentration factor, demonstrating a clear sensitivity enhancement in the colorimetric lateral flow assay; consequently, clear colors are observed in a rapid kit test line, which cannot be monitored without preconcentration. This device can also facilitate a semi-quantitative platform using the saturation value and/or color intensity in both paper-based colorimetric assays and smartphone-based diagnostics.
Cell-free synthetic biology for in vitro prototype engineering
Moore, Simon J.; MacDonald, James T.
2017-01-01
Cell-free transcription–translation is an expanding field in synthetic biology as a rapid prototyping platform for blueprinting the design of synthetic biological devices. Exemplar efforts include translation of prototype designs into medical test kits for on-site identification of viruses (Zika and Ebola), while gene circuit cascades can be tested, debugged and re-designed within rapid turnover times. Coupled with mathematical modelling, this discipline lends itself towards the precision engineering of new synthetic life. The next stages of cell-free look set to unlock new microbial hosts that remain slow to engineer and unsuited to rapid iterative design cycles. It is hoped that the development of such systems will provide new tools to aid the transition from cell-free prototype designs to functioning synthetic genetic circuits and engineered natural product pathways in living cells. PMID:28620040
Oliveira, E; Oliveira, D; Cardoso, F A; Barbosa, J R; Marcelino, A P; Dutra, T; Araujo, T; Fernandes, L; Duque, D; Rabello, A
2017-12-01
In this study, we assessed the sensitivity, specificity, and diagnostic accuracy of a previously developed direct agglutination test (DAT) using a freeze-dried antigen derived from Leishmania infantum promastigotes and composed in a prototype kit for visceral leishmaniasis (VL) diagnosis, named DAT-LPC. To evaluate DAT-LPC reproducibility, the kit was used to analyse 207 serum samples from VL patients and 80 serum samples from patients with other parasitic infections or healthy subjects in four laboratories from different public health institutions in Brazil. DAT-LPC showed sensitivity between 96·2 and 99·5% (P = 0·14), specificity ranging from 96·2 to 97·5% (P = 0·95), and diagnostic accuracy ranging from 96·5 to 99% (P = 0·34). The inter-laboratory reproducibility of qualitative results was classified as excellent (κ index: 0·94-0·97). The reproducibility of the end-titre results in relation to the reference laboratory, ranged from 31 to 85%. These results demonstrate an excellent performance of the DAT-LPC, and validate it for the diagnosis of VL that could replace the immunofluorescent antibody test as the routine diagnostic test in the Brazilian public health system.
Sultana, Farhana; Mullins, Robyn; Murphy, Michael; English, Dallas R; Simpson, Julie A; Drennan, Kelly T; Heley, Stella; Wrede, C David; Brotherton, Julia M L; Saville, Marion; Gertig, Dorota M
2015-08-01
Background The study evaluated acceptability, invitation letters and the test kit for a trial of human papillomavirus (HPV) self-sampling among never- and under-screened women in Australia. Victorian women, 30-69 years, who had never had a Pap test or were overdue for one, participated. Four focus groups including eight to nine participants segmented by age (30-49 and 50-69 years) and screening history (never- and under-screened) were conducted in August 2013. Discussions were recorded and transcribed verbatim and data analysed using thematic content analysis. The response to the concept of HPV self-sampling was positive. Decision-making was largely influenced by the content of a pre-invitation letter. Appealing features of self-sampling were cost (free), convenience (home-based) and anticipated less discomfort (with a swab) than a Pap test. Small kits that fit in mailboxes were preferred over post office parcel collection. The perceived barriers include concerns about test accuracy and lack of confidence that a home-based test would give the same results as a physician administered test. Women wanted information on the timing of receipt of the results and information about the organisation providing the test. HPV self-sampling is a possible alternative for Australian women who are reluctant to have a Pap test and may increase the likelihood of participation in cervical cancer screening if women's concerns about it can be addressed. The findings of this study are relevant for researchers, policymakers and practitioners implementing self-sampling for under-screened women as part of cervical screening programs.
Online Social Networking for HIV Education and Prevention: A Mixed Methods Analysis
Young, Sean D.; Jaganath, Devan
2013-01-01
Background The purpose of this study is to use mixed (qualitative/quantitative) methods to determine 1) the feasibility and acceptability of using online social networking to facilitate HIV-related discussions, and 2) the relationship between HIV-related online discussions and requests for a home-based HIV testing kit, among men who have sex with men (MSM). Methods Participants, primarily African American and Latino, were invited to join a “secret” group on the social networking website, Facebook. Peer leaders, trained in HIV prevention, posted HIV-related content. Participants were not obligated to respond to discussions or remain within the group. Participant public group conversations were qualitatively and thematically analyzed. Quantitative methods tested associations between qualitative data, participants’ demographic information, and likelihood of requesting a home-based HIV testing kit. Results Latino and African-American participants (N=57) voluntarily used Facebook to discuss the following HIV-related topics (N=485 conversations): Prevention and Testing; Knowledge; Stigma; and Advocacy. Older participants more frequently discussed Prevention and Testing, Stigma, and Advocacy, though younger participants more frequently discussed HIV Knowledge-related conversations. As the study progressed, the proportion of messages related to Prevention and Testing and HIV Stigma increased. Multivariate analysis showed that participants posting about HIV Prevention and Testing (compared to those who did not) were significantly more likely to request an HIV testing kit (OR 11.14, p = 0.001). Conclusions Facebook can serve as an innovative forum to increase both HIV prevention discussions and HIV testing requests among at-risk groups. PMID:23324979
[Isolation and identification methods of enterobacteria group and its technological advancement].
Furuta, Itaru
2007-08-01
In the last half-century, isolation and identification methods of enterobacteria groups have markedly improved by technological advancement. Clinical microbiology tests have changed overtime from tube methods to commercial identification kits and automated identification. Tube methods are the original method for the identification of enterobacteria groups, that is, a basically essential method to recognize bacterial fermentation and biochemical principles. In this paper, traditional tube tests are discussed, such as the utilization of carbohydrates, indole, methyl red, and citrate and urease tests. Commercial identification kits and automated instruments by computer based analysis as current methods are also discussed, and those methods provide rapidity and accuracy. Nonculture techniques of nucleic acid typing methods using PCR analysis, and immunochemical methods using monoclonal antibodies can be further developed.
New designs for portable Raman instrumentation in defense applications
NASA Astrophysics Data System (ADS)
Carron, Keith; Ray, Bryan; Buller, Shane; Strickland, Aaron
2016-05-01
The realization of global terrorism after the September 11 attacks led immediately to a need for rapid field analysis of materials. Colorimetric test kits existed, but they are very subjective to interpret and they require contact with the sample. A push for handheld spectrometers quickly led to FTIR systems with ATR sampling, handheld IMS systems, and handheld Raman spectrometers. No single technique solves all of the problems of field detection. We will discuss the development of Raman instrumentation and, in particular, cover the advantages and the problems that are inherent in Raman portability. Portable Raman instrumentation began with a limited number of accessories: a point-and-shoot and some sort of vial adaptor. Currently this has expanded to stand-off attachments for measurements at a distance, air sampling to look for toxic gasses or aerosols, Orbital Raster Scan (ORS) to spatially average over samples, SERS attachments for trace detection, and fiber optic probes.
SAS molecular tests Escherichia coli O157 detection kit. Performance tested method 031203.
Bapanpally, Chandra; Montier, Laura; Khan, Shah; Kasra, Akif; Brunelle, Sharon L
2014-01-01
The SAS Molecular tests Escherichia coli O157 Detection method, a loop-mediated isothermal amplification method, performed as well as or better than the U.S. Department of Agriculture, Food Safety Inspection Service Microbiology Laboratory Guidebook and the U.S. Food and Drug Administration Bacteriological Analytical Manual reference methods for ground beef, beef trim, bagged mixed lettuce, and fresh spinach. Ground beef (30% fat, 25 g test portion) was validated for 7-8 h enrichment, leafy greens were validated in a 6-7 h enrichment, and ground beef (30% fat, 375 g composite test portion) and beef trim (375 g composite test portion) were validated in a 16-20 h enrichment. The method performance for meat and leafy green matrixes was also shown to be acceptable under conditions of co-enrichment with Salmonella. Thus, after a short co-enrichment step, ground beef, beef trim, lettuce, and spinach can be tested for both Salmonella and E. coli O157. The SAS Molecular tests Salmonella Detection Kit was validated using the same test portions as for the SAS Molecular tests E. coli O157 Detection Kit and those results are presented in a separate report. Inclusivity and exclusivity testing revealed no false negatives and no false positives among the 50 E. coli 0157 strains, including H7 and non-motile strains, and 30 non-E. coli O157 strains examined. Finally, the method was shown to be robust when variations to DNA extract hold time and DNA volume were varied. The method comparison and robustness data suggest a full 7 h enrichment time should be used for 25 g ground beef test portions.
Clinical Evaluation of a Loop-Mediated Amplification Kit for Diagnosis of Imported Malaria
Polley, Spencer D.; González, Iveth J.; Mohamed, Deqa; Daly, Rosemarie; Bowers, Kathy; Watson, Julie; Mewse, Emma; Armstrong, Margaret; Gray, Christen; Perkins, Mark D.; Bell, David; Kanda, Hidetoshi; Tomita, Norihiro; Kubota, Yutaka; Mori, Yasuyoshi; Chiodini, Peter L.; Sutherland, Colin J.
2013-01-01
Background. Diagnosis of malaria relies on parasite detection by microscopy or antigen detection; both fail to detect low-density infections. New tests providing rapid, sensitive diagnosis with minimal need for training would enhance both malaria diagnosis and malaria control activities. We determined the diagnostic accuracy of a new loop-mediated amplification (LAMP) kit in febrile returned travelers. Methods. The kit was evaluated in sequential blood samples from returned travelers sent for pathogen testing to a specialist parasitology laboratory. Microscopy was performed, and then malaria LAMP was performed using Plasmodium genus and Plasmodium falciparum–specific tests in parallel. Nested polymerase chain reaction (PCR) was performed on all samples as the reference standard. Primary outcome measures for diagnostic accuracy were sensitivity and specificity of LAMP results, compared with those of nested PCR. Results. A total of 705 samples were tested in the primary analysis. Sensitivity and specificity were 98.4% and 98.1%, respectively, for the LAMP P. falciparum primers and 97.0% and 99.2%, respectively, for the Plasmodium genus primers. Post hoc repeat PCR analysis of all 15 tests with discrepant results resolved 4 results in favor of LAMP, suggesting that the primary analysis had underestimated diagnostic accuracy. Conclusions. Malaria LAMP had a diagnostic accuracy similar to that of nested PCR, with a greatly reduced time to result, and was superior to expert microscopy. PMID:23633403
NASA Astrophysics Data System (ADS)
Johari, A. H.; Muslim
2018-05-01
Experiential learning model using simple physics kit has been implemented to get a picture of improving attitude toward physics senior high school students on Fluid. This study aims to obtain a description of the increase attitudes toward physics senior high school students. The research method used was quasi experiment with non-equivalent pretest -posttest control group design. Two class of tenth grade were involved in this research 28, 26 students respectively experiment class and control class. Increased Attitude toward physics of senior high school students is calculated using an attitude scale consisting of 18 questions. Based on the experimental class test average of 86.5% with the criteria of almost all students there is an increase and in the control class of 53.75% with the criteria of half students. This result shows that the influence of experiential learning model using simple physics kit can improve attitude toward physics compared to experiential learning without using simple physics kit.
Evaluation Of A Powder-Free DNA Extraction Method For Skeletal Remains.
Harrel, Michelle; Mayes, Carrie; Gangitano, David; Hughes-Stamm, Sheree
2018-02-07
Bones are often recovered in forensic investigations, including missing persons and mass disasters. While traditional DNA extraction methods rely on grinding bone into powder prior to DNA purification, the TBone Ex buffer (DNA Chip Research Inc.) digests bone chips without powdering. In this study, six bones were extracted using the TBone Ex kit in conjunction with the PrepFiler ® BTA™ DNA extraction kit (Thermo Fisher Scientific) both manually and via an automated platform. Comparable amounts of DNA were recovered from a 50 mg bone chip using the TBone Ex kit and 50 mg of powdered bone with the PrepFiler ® BTA™ kit. However, automated DNA purification decreased DNA yield (p < 0.05). Nevertheless, short tandem repeat (STR) success was comparable across all methods tested. This study demonstrates that digestion of whole bone fragments is an efficient alternative to powdering bones for DNA extraction without compromising downstream STR profile quality. © 2018 American Academy of Forensic Sciences.
STR-typing of ancient skeletal remains: which multiplex-PCR kit is the best?
Harder, Melanie; Renneberg, Rebecca; Meyer, Patrick; Krause-Kyora, Ben; von Wurmb-Schwark, Nicole
2012-01-01
Aim To comparatively test nine commercially available short tandem repeat (STR)-multiplex kits (PowerPlex 16, 16HS, ES, ESI17, ESX17, S5 [all Promega]; AmpFiSTR Identifiler, NGM and SEfiler [all Applied Biosystems]) for their efficiency and applicability to analyze ancient and thus highly degraded DNA samples. Methods Fifteen human skeletal remains from the late medieval age were obtained and analyzed using the nine polymerase chain reaction assays with slightly modified protocols. Data were systematically compared to find the most meaningful and sensitive assay. Results The ESI, ESX, and NGM kits showed the best overall results regarding amplification success, detection rate, identification of heterozygous alleles, sex determination, and reproducibility of the obtained data. Conclusion Since application of these three kits enables the employment of different primer sequences for all the investigated amplicons, a combined application is recommended for best possible and – most importantly – reliable genetic analysis of ancient skeletal material or otherwise highly degraded samples, eg, from forensic cases. PMID:23100203
Active and realistic passive marijuana exposure tested by three immunoassays and GC/MS in urine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mule, S.J.; Lomax, P.; Gross, S.J.
Human urine samples obtained before and after active and passive exposure to marijuana were analyzed by immune kits (Roche, Amersham, and Syva) and gas chromatography/mass spectrometry (GC/MS). Seven of eight subjects were positive for the entire five-day test period with one immune kit. The latter correlated with GC/MS in 98% of the samples. Passive inhalation experiments under conditions likely to reflect realistic exposure resulted consistently in less than 10 ng/mL of cannabinoids. The 10-100-ng/mL cannabinoid concentration range essential for detection of occasional and moderate marijuana users is thus unaffected by realistic passive inhalation.
Sánchez-Vargas, Luis A; Sánchez-Marce, Elvis E; Vivanco-Cid, Héctor
2014-04-01
In this study, we evaluated the performance of a rapid test, the SD BIOLINE Dengue Duo (SD BDD) kit, with a panel of serum samples from 310 Mexican patients with diagnosis of dengue infection previously confirmed by reference enzyme-linked immunosorbent assay tests. Eighty-seven negative samples from other febrile illnesses were included as controls. The SD BDD showed an overall sensitivity of 90.65% and specificity of 89.66%. No statistically significant differences were found in the sensitivity of the SD BDD kit compared between primary or secondary infections (87.05% versus 93.57%, respectively, P = 0.0761) and dengue fever or dengue hemorrhagic fever cases (90.77% versus 89.74%, respectively, P = 0.7716). However, a higher sensitivity in the acute phase of dengue infection was found compared with the convalescent phase (93.03% versus 81.82%, respectively, P = 0.0089). These results indicate that the SD BDD kit is a useful tool to diagnose dengue infections, both in primary or secondary infections and mainly during the acute phase. Copyright © 2014 Elsevier Inc. All rights reserved.
Peter, Harald; Berggrav, Kathrine; Thomas, Peter; Pfeifer, Yvonne; Witte, Wolfgang; Templeton, Kate
2012-01-01
Klebsiella pneumoniae carbapenemases (KPCs) are considered a serious threat to antibiotic therapy, as they confer resistance to carbapenems, which are used to treat extended-spectrum beta-lactamase (ESBL)-producing bacteria. Here, we describe the development and evaluation of a DNA microarray for the detection and genotyping of KPC genes (blaKPC) within a 5-h period. To test the whole assay procedure (DNA extraction plus a DNA microarray assay) directly from clinical specimens, we compared two commercial DNA extraction kits (the QIAprep Spin miniprep kit [Qiagen] and the urine bacterial DNA isolation kit [Norgen]) for the direct DNA extraction from urine samples (dilution series spiked in human urine). Reliable single nucleotide polymorphism (SNP) typing was demonstrated using 1 × 105 CFU/ml urine for Escherichia coli (Qiagen and Norgen) and 80 CFU/ml urine, on average, for K. pneumoniae (Norgen). This study presents, for the first time, the combination of a new KPC microarray with commercial sample preparation for detecting and genotyping microbial pathogens directly from clinical specimens; this paves the way toward tests providing epidemiological and diagnostic data, enabling better antimicrobial stewardship. PMID:23035190
Caliskan, Ahmet; Kirisci, Ozlem; Ozkaya, Esra; Ozden, Sevinc; Tumer, Seray; Caglar, Serkan; Guler, Selma Ates; Senol, Hande
2015-04-01
The hepatitis C virus (HCV) has six major genotypes and more than 100 subtypes, and the determination of the responsible genotype, collection of epidemiological data, tailoring antiviral therapy, and prediction of prognosis have an important place in disease management. The aim of the present study was to determine the distribution of HCV genotypes across geographic regions and compare these data with those obtained from other geographic locations. The HCV genotypes were identified in HCV RNA positive blood samples, obtained from different centers. The HCV genotype was determined using molecular methods [Real-Time Polymerase Chain Reaction (RT-PCR)] in 313 patients, who were found to be positive for HCV RNA. The presence of HCV RNA was investigated using the RT-PCR method in serum samples delivered to the Microbiology Laboratory at Kahramanmaras Necip Fazıl City Hospital, Kahramanmaras, Turkey, from the centers located in Kahramanmaras City center and peripheral districts of the province, between March 2010 and August 2014. The HCV genotype analysis was performed in HCV RNA positive samples, using RT-PCR reagents kit. Urine samples from the patients were tested for amphetamine with an Amphetamines II (AMPS2) kit, cocaine was tested with a Cocaine II (COC2) kit, opiates were tested with an Opiates II (OPI2) kit, and cannabinoids were tested with a Cannabinoids II (THC2) kit in Roche/Hitachi Cobas c501 device. The blood samples collected from 313 patients were included in the study. Of these patients, 212 (67.7%) were male and 101 (32.3%) were female. The mean age of the patients was 41.29 ± 20.32 years. In terms of HCV genotype distribution, 162 patients (51.7%) had genotype 1, 144 patients (46%) had genotype 3, four patients (1.3%) had genotype 2, and three patients (1%) had genotype 4. The results of urine drug tests were available in only 65 patients (20.2%). Of these, 61 (93.8%) patients had HCV genotype 3. In conclusion, the prevalence of HCV genotype 1 was 51.7%, which was lower than the rates reported in other studies in Turkey, while the prevalence of HCV genotype 3 was 46%, which was remarkably higher than the reported Turkish data. In addition, the prevalence rate for genotype 3 reported in the present study is the highest that has ever been reported in the literature.
Assessment of RFID Read Accuracy for ISS Water Kit
NASA Technical Reports Server (NTRS)
Chu, Andrew
2011-01-01
The Space Life Sciences Directorate/Medical Informatics and Health Care Systems Branch (SD4) is assessing the benefits Radio Frequency Identification (RFID) technology for tracking items flown onboard the International Space Station (ISS). As an initial study, the Avionic Systems Division Electromagnetic Systems Branch (EV4) is collaborating with SD4 to affix RFID tags to a water kit supplied by SD4 and studying the read success rate of the tagged items. The tagged water kit inside a Cargo Transfer Bag (CTB) was inventoried using three different RFID technologies, including the Johnson Space Center Building 14 Wireless Habitat Test Bed RFID portal, an RFID hand-held reader being targeted for use on board the ISS, and an RFID enclosure designed and prototyped by EV4.
A chromosome inversion near the KIT gene and the Tobiano spotting pattern in horses.
Brooks, S A; Lear, T L; Adelson, D L; Bailey, E
2007-01-01
Tobiano is a white spotting pattern in horses caused by a dominant gene, Tobiano(TO). Here, we report TO associated with a large paracentric chromosome inversion on horse chromosome 3. DNA sequences flanking the inversion were identified and a PCR test was developed to detect the inversion. The inversion was only found in horses with the tobiano pattern, including horses with diverse genetic backgrounds, which indicated a common genetic origin thousands of years ago. The inversion does not interrupt any annotated genes, but begins approximately 100 kb downstream of the KIT gene. This inversion may disrupt regulatory sequences for the KIT gene and cause the white spotting pattern. Copyright (c) 2008 S. Karger AG, Basel.
Peng, Xin; Yu, Ke-Qiang; Deng, Guan-Hua; Jiang, Yun-Xia; Wang, Yu; Zhang, Guo-Xia; Zhou, Hong-Wei
2013-12-01
Low cost and high throughput capacity are major advantages of using next generation sequencing (NGS) techniques to determine metagenomic 16S rRNA tag sequences. These methods have significantly changed our view of microorganisms in the fields of human health and environmental science. However, DNA extraction using commercial kits has shortcomings of high cost and time constraint. In the present study, we evaluated the determination of fecal microbiomes using a direct boiling method compared with 5 different commercial extraction methods, e.g., Qiagen and MO BIO kits. Principal coordinate analysis (PCoA) using UniFrac distances and clustering showed that direct boiling of a wide range of feces concentrations gave a similar pattern of bacterial communities as those obtained from most of the commercial kits, with the exception of the MO BIO method. Fecal concentration by boiling method affected the estimation of α-diversity indices, otherwise results were generally comparable between boiling and commercial methods. The operational taxonomic units (OTUs) determined through direct boiling showed highly consistent frequencies with those determined through most of the commercial methods. Even those for the MO BIO kit were also obtained by the direct boiling method with high confidence. The present study suggested that direct boiling could be used to determine the fecal microbiome and using this method would significantly reduce the cost and improve the efficiency of the sample preparation for studying gut microbiome diversity. © 2013 Elsevier B.V. All rights reserved.
Hysteroscopic sterilization: 10-year retrospective analysis of worldwide pregnancy reports.
Munro, M G; Nichols, J E; Levy, B; Vleugels, M P H; Veersema, S
2014-01-01
To identify factors that might contribute to pregnancies reported after hysteroscopic sterilization worldwide. Retrospective review of commercial data compiled from the MAUDE database, medical literature, and manufacturer reports received during commercial distribution of hysteroscopic sterilization micro-inserts from 2001 through 2010 (Canadian Taskforce classification III descriptive study). From 2001 through 2010, 497 305 hysteroscopic sterilization kits were distributed worldwide, and 748 pregnancies were reported, i.e., 0.15% of the estimated user population based on the number of distributed kits. The data were sufficient to enable analysis of 508 pregnancies for potential contributing factors and showed most to be associated with patient or physician noncompliance (n = 264) or misinterpreted confirmation tests (n = 212). Conceptions deemed to have occurred within 2 weeks of the procedure and therefore too early for detection were identified in 32 cases. Although there are limitations to the dataset and the study design is retrospective, it represents the largest body of cumulative hysteroscopic sterilization data available to date. Of the 748 pregnancies reported, it is apparent that some might have been prevented with greater patient and clinician attention to interim contraceptive use and counseling and with more rigorous evaluation and informed interpretation of the procedure confirmation tests. Although the estimated pregnancy rate based on such a dataset is likely an underestimation, it does suggest that the evaluable field performance of hysteroscopic sterilization micro-inserts is consistent with the labeled age-adjusted effectiveness of 99.74% at 5 years. Copyright © 2014 AAGL. Published by Elsevier Inc. All rights reserved.
Scoles, Glen A; Goff, Will L; Lysyk, Timothy J; Lewis, Gregory S; Knowles, Donald P
2008-07-27
A commercially available (cELISA) kit for diagnosing Anaplasma marginale infection in cattle was validated for diagnosing A ovis infection in sheep using the bovine serum controls as supplied by the manufacturer (BcELISA) and sheep serum controls from pathogen-free sheep (OcELISA). True positives were identified using two previously established assays, a nested PCR (nPCR) test and an indirect immunofluorescent assay (IFA). The BcELISA was also applied to sera from various species of wild ruminants, comparing the results with the IFA. Receiver operating characteristic (ROC) analysis indicated that the predicted threshold inhibition for the BcELISA was 19.2. The sensitivity for the BcELISA was 98.2% and the specificity was 96.3%. The predicted threshold inhibition decreased to 14.3 for the OcELISA; the sensitivity was 96.5% and the specificity was 98.1%. There was >/=90% concordance between IFA and nPCR, as well as between the BcELISA at 19% inhibition cutoff and either IFA or PCR. Concordance between the cELISA and IFA using sera from elk, mule deer, bighorn sheep, pronghorn antelope, and black-tailed deer ranged from 64% to 100%. This commercially available cELISA test kit can be used very effectively to test domestic sheep for infection with A. ovis using the kit-supplied controls (i.e. the BcELISA) and a 19% inhibition cutoff; the kit may also be useful for detecting intra-erythrocytic Anaplasma infections in wild ruminants.
Zhang, Heng; Lan, Fang; Shi, Yupeng; Wan, Zhi-Gang; Yue, Zhen-Feng; Fan, Fang; Lin, Yan-Kui; Tang, Mu-Jin; Lv, Jing-Zhang; Xiao, Tan; Yi, Changqing
2014-06-15
VitaFast(®) test kits designed for the microbiological assay in microtiter plate format can be applied to quantitative determination of B-group water-soluble vitamins such as vitamin B12, folic acid and biotin, et al. Compared to traditional microbiological methods, VitaFast(®) kits significantly reduce sample processing time and provide greater reliability, higher productivity and better accuracy. Recently, simultaneous determination of vitamin B12, folic acid and biotin in one sample is urgently required when evaluating the quality of infant formulae in our practical work. However, the present sample preparation protocols which are developed for individual test systems, are incompatible with simultaneous determination of several analytes. To solve this problem, a novel "three-in-one" sample preparation method is herein developed for simultaneous determination of B-group water-soluble vitamins using VitaFast(®) kits. The performance of this novel "three-in-one" sample preparation method was systematically evaluated through comparing with individual sample preparation protocols. The experimental results of the assays which employed "three-in-one" sample preparation method were in good agreement with those obtained from conventional VitaFast(®) extraction methods, indicating that the proposed "three-in-one" sample preparation method is applicable to the present three VitaFast(®) vitamin test systems, thus offering a promising alternative for the three independent sample preparation methods. The proposed new sample preparation method will significantly improve the efficiency of infant formulae inspection. Copyright © 2013 Elsevier Ltd. All rights reserved.