Sample records for field test method

  1. Hydrogen Field Test Standard: Laboratory and Field Performance

    PubMed Central

    Pope, Jodie G.; Wright, John D.

    2015-01-01

    The National Institute of Standards and Technology (NIST) developed a prototype field test standard (FTS) that incorporates three test methods that could be used by state weights and measures inspectors to periodically verify the accuracy of retail hydrogen dispensers, much as gasoline dispensers are tested today. The three field test methods are: 1) gravimetric, 2) Pressure, Volume, Temperature (PVT), and 3) master meter. The FTS was tested in NIST's Transient Flow Facility with helium gas and in the field at a hydrogen dispenser location. All three methods agree within 0.57 % and 1.53 % for all test drafts of helium gas in the laboratory setting and of hydrogen gas in the field, respectively. The time required to perform six test drafts is similar for all three methods, ranging from 6 h for the gravimetric and master meter methods to 8 h for the PVT method. The laboratory tests show that 1) it is critical to wait for thermal equilibrium to achieve density measurements in the FTS that meet the desired uncertainty requirements for the PVT and master meter methods; in general, we found a wait time of 20 minutes introduces errors < 0.1 % and < 0.04 % in the PVT and master meter methods, respectively and 2) buoyancy corrections are important for the lowest uncertainty gravimetric measurements. The field tests show that sensor drift can become a largest component of uncertainty that is not present in the laboratory setting. The scale was calibrated after it was set up at the field location. Checks of the calibration throughout testing showed drift of 0.031 %. Calibration of the master meter and the pressure sensors prior to travel to the field location and upon return showed significant drifts in their calibrations; 0.14 % and up to 1.7 %, respectively. This highlights the need for better sensor selection and/or more robust sensor testing prior to putting into field service. All three test methods are capable of being successfully performed in the field and give equivalent answers if proper sensors without drift are used. PMID:26722192

  2. A Novel Method for Quantifying Helmeted Field of View of a Spacesuit - And What It Means for Constellation

    NASA Technical Reports Server (NTRS)

    McFarland, Shane M.

    2010-01-01

    Field of view has always been a design feature paramount to helmet design, and in particular spacesuit design, where the helmet must provide an adequate field of view for a large range of activities, environments, and body positions. Historically, suited field of view has been evaluated either qualitatively in parallel with design or quantitatively using various test methods and protocols. As such, oftentimes legacy suit field of view information is either ambiguous for lack of supporting data or contradictory to other field of view tests performed with different subjects and test methods. This paper serves to document a new field of view testing method that is more reliable and repeatable than its predecessors. It borrows heavily from standard ophthalmologic field of vision tests such as the Goldmann kinetic perimetry test, but is designed specifically for evaluating field of view of a spacesuit helmet. In this test, four suits utilizing three different helmet designs were tested for field of view. Not only do these tests provide more reliable field of view data for legacy and prototype helmet designs, they also provide insight into how helmet design impacts field of view and what this means for the Constellation Project spacesuit helmet, which must meet stringent field of view requirements that are more generous to the crewmember than legacy designs.

  3. The importance of aerodynamics for prosthetic limb design used by competitive cyclists with an amputation: An introduction.

    PubMed

    Dyer, Bryce

    2015-06-01

    This study introduces the importance of the aerodynamics to prosthetic limb design for athletes with either a lower-limb or upper-limb amputation. The study comprises two elements: 1) An initial experiment investigating the stability of outdoor velodrome-based field tests, and 2) An experiment evaluating the application of outdoor velodrome aerodynamic field tests to detect small-scale changes in aerodynamic drag respective of prosthetic limb componentry changes. An outdoor field-testing method is used to detect small and repeatable changes in the aerodynamic drag of an able-bodied cyclist. These changes were made at levels typical of alterations in prosthetic componentry. The field-based test method of assessment is used at a smaller level of resolution than previously reported. With a carefully applied protocol, the field test method proved to be statistically stable. The results of the field test experiments demonstrate a noticeable change in overall athlete performance. Aerodynamic refinement of artificial limbs is worthwhile for athletes looking to maximise their competitive performance. A field-testing method illustrates the importance of the aerodynamic optimisation of prosthetic limb components. The field-testing protocol undertaken in this study gives an accessible and affordable means of doing so by prosthetists and sports engineers. Using simple and accessible field-testing methods, this exploratory experiment demonstrates how small changes to riders' equipment, consummate of the scale of a small change in prosthetics componentry, can affect the performance of an athlete. Prosthetists should consider such opportunities for performance enhancement when possible. © The International Society for Prosthetics and Orthotics 2014.

  4. Field measurements of the linear and nonlinear shear moduli of cemented alluvium using dynamically loaded surface footings

    NASA Astrophysics Data System (ADS)

    Park, Kwangsoo

    In this dissertation, a research effort aimed at development and implementation of a direct field test method to evaluate the linear and nonlinear shear modulus of soil is presented. The field method utilizes a surface footing that is dynamically loaded horizontally. The test procedure involves applying static and dynamic loads to the surface footing and measuring the soil response beneath the loaded area using embedded geophones. A wide range in dynamic loads under a constant static load permits measurements of linear and nonlinear shear wave propagation from which shear moduli and associated shearing strains are evaluated. Shear wave velocities in the linear and nonlinear strain ranges are calculated from time delays in waveforms monitored by geophone pairs. Shear moduli are then obtained using the shear wave velocities and the mass density of a soil. Shear strains are determined using particle displacements calculated from particle velocities measured at the geophones by assuming a linear variation between geophone pairs. The field test method was validated by conducting an initial field experiment at sandy site in Austin, Texas. Then, field experiments were performed on cemented alluvium, a complex, hard-to-sample material. Three separate locations at Yucca Mountain, Nevada were tested. The tests successfully measured: (1) the effect of confining pressure on shear and compression moduli in the linear strain range and (2) the effect of strain on shear moduli at various states of stress in the field. The field measurements were first compared with empirical relationships for uncemented gravel. This comparison showed that the alluvium was clearly cemented. The field measurements were then compared to other independent measurements including laboratory resonant column tests and field seismic tests using the spectral-analysis-of-surface-waves method. The results from the field tests were generally in good agreement with the other independent test results, indicating that the proposed method has the ability to directly evaluate complex material like cemented alluvium in the field.

  5. Determination of antenna factors using a three-antenna method at open-field test site

    NASA Astrophysics Data System (ADS)

    Masuzawa, Hiroshi; Tejima, Teruo; Harima, Katsushige; Morikawa, Takao

    1992-09-01

    Recently NIST has used the three-antenna method for calibration of the antenna factor of an antenna used for EMI measurements. This method does not require the specially designed standard antennas which are necessary in the standard field method or the standard antenna method, and can be used at an open-field test site. This paper theoretically and experimentally examines the measurement errors of this method and evaluates the precision of the antenna-factor calibration. It is found that the main source of the error is the non-ideal propagation characteristics of the test site, which should therefore be measured before the calibration. The precision of the antenna-factor calibration at the test site used in these experiments, is estimated to be 0.5 dB.

  6. Visual field examination method using virtual reality glasses compared with the Humphrey perimeter.

    PubMed

    Tsapakis, Stylianos; Papaconstantinou, Dimitrios; Diagourtas, Andreas; Droutsas, Konstantinos; Andreanos, Konstantinos; Moschos, Marilita M; Brouzas, Dimitrios

    2017-01-01

    To present a visual field examination method using virtual reality glasses and evaluate the reliability of the method by comparing the results with those of the Humphrey perimeter. Virtual reality glasses, a smartphone with a 6 inch display, and software that implements a fast-threshold 3 dB step staircase algorithm for the central 24° of visual field (52 points) were used to test 20 eyes of 10 patients, who were tested in a random and consecutive order as they appeared in our glaucoma department. The results were compared with those obtained from the same patients using the Humphrey perimeter. High correlation coefficient ( r =0.808, P <0.0001) was found between the virtual reality visual field test and the Humphrey perimeter visual field. Visual field examination results using virtual reality glasses have a high correlation with the Humphrey perimeter allowing the method to be suitable for probable clinical use.

  7. Red square test for visual field screening. A sensitive and simple bedside test.

    PubMed

    Mandahl, A

    1994-12-01

    A reliable bedside test for screening of visual field defects is a valuable tool in the examination of patients with a putative disease affecting the sensory visual pathways. Conventional methods such as Donders' confrontation method, counting fingers in the visual field periphery, of two-hand confrontation are not sufficiently sensitive to detect minor but nevertheless serious visual field defects. More sensitive methods requiring only simple tools are also described. In this study, a test card with four red squares surrounding a fixation target, a black dot, with a total test area of about 11 x 12.5 degrees at a distance of 30 cm, was designed for testing experience of red colour saturation in four quadrants, red square test. The Goldmann visual field was used as reference. 125 consecutive patients with pituitary adenoma (159 eyes), craniopharyngeoma (9 eyes), meningeoma (21 eyes), vascular hemisphere lesion (40 eyes), hemisphere tumour (10 eyes) and hemisphere abscess (2 eyes) were examined. The Goldmann visual field and red square test were pathological in pituitary adenomas in 35%, in craniopharyngeomas in 44%, in meningeomas in 52% and in hemisphere tumours or abscess in 100% of the eyes. Among these, no false-normal or false-pathological tests were found. However, in vascular hemisphere disease the corresponding figures were Goldmann visual field 90% and red square test 85%. The 5% difference (4 eyes) was due to Goldmann visual field defects strictly peripheral to the central 15 degrees. These defects were easily diagnosed with two-hand confrontation and

  8. A Primer-Test Centered Equating Method for Setting Cut-Off Scores

    ERIC Educational Resources Information Center

    Zhu, Weimo; Plowman, Sharon Ann; Park, Youngsik

    2010-01-01

    This study evaluated the use of a new primary field test method based on test equating to address inconsistent classification among field tests. We analyzed students' information on the Progressive Aerobic Cardiovascular Endurance Run (PACER), mile run (MR), and VO[subscript 2]max from three data sets (college: n = 94; middle school: n = 39;…

  9. Bioelectrical Impedance and Body Composition Assessment

    ERIC Educational Resources Information Center

    Martino, Mike

    2006-01-01

    This article discusses field tests that can be used in physical education programs. The most common field tests are anthropometric measurements, which include body mass index (BMI), girth measurements, and skinfold testing. Another field test that is gaining popularity is bioelectrical impedance analysis (BIA). Each method has particular strengths…

  10. Specific Yields Estimated from Gravity Change during Pumping Test

    NASA Astrophysics Data System (ADS)

    Chen, K. H.; Hwang, C.; Chang, L. C.

    2017-12-01

    Specific yield (Sy) is the most important parameter to describe available groundwater capacity in an unconfined aquifer. When estimating Sy by a field pumping test, aquifer heterogeneity and well performers will cause a large uncertainty. In this study, we use a gravity-based method to estimate Sy. At the time of pumping test, amounts of mass (groundwater) are forced to be taken out. If drawdown corn is big and close enough to high precision gravimeter, the gravity change can be detected. The gravity-based method use gravity observations that are independent from traditional flow computation. Only the drawdown corn should be modeled with observed head and hydrogeology data. The gravity method can be used in most groundwater field tests, such as locally pumping/injection tests initiated by active man-made or annual variations due to natural sources. We apply our gravity method at few sites in Taiwan situated over different unconfined aquifer. Here pumping tests for Sy determinations were also carried out. We will discuss why the gravity method produces different results from traditional pumping test, field designs and limitations of the gravity method.

  11. A study: Effect of Students Peer Assisted Learning on Magnetic Field Achievement

    NASA Astrophysics Data System (ADS)

    Mueanploy, Wannapa

    2016-04-01

    This study is the case study of Physic II Course for students of Pathumwan Institute of Technology. The purpose of this study is: 1) to develop cooperative learning method of peer assisted learning (PAL), 2) to compare the learning achievement before and after studied magnetic field lesson by cooperative learning method of peer assisted learning. The population was engineering students of Pathumwan Institute of Technology (PIT’s students) who registered Physic II Course during year 2014. The sample used in this study was selected from the 72 students who passed in Physic I Course. The control groups learning magnetic fields by Traditional Method (TM) and experimental groups learning magnetic field by method of peers assisted learning. The students do pretest before the lesson and do post-test after the lesson by 20 items achievement tests of magnetic field. The post-test higher than pretest achievement significantly at 0.01 level.

  12. Collection of quantitative chemical release field data.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Demirgian, J.; Macha, S.; Loyola Univ.

    1999-01-01

    Detection and quantitation of chemicals in the environment requires Fourier-transform infrared (FTIR) instruments that are properly calibrated and tested. This calibration and testing requires field testing using matrices that are representative of actual instrument use conditions. Three methods commonly used for developing calibration files and training sets in the field are a closed optical cell or chamber, a large-scale chemical release, and a small-scale chemical release. There is no best method. The advantages and limitations of each method should be considered in evaluating field results. Proper calibration characterizes the sensitivity of an instrument, its ability to detect a component inmore » different matrices, and the quantitative accuracy and precision of the results.« less

  13. Draft version 1.0 final report : evaluation methods and lessons learned from the Minnesota Department of Transportation intelligent vehicle initiative field operational test

    DOT National Transportation Integrated Search

    2003-09-26

    This report on the Evaluation Methods and Lessons Learned for the Mn/DOT Intelligent Vehicle Initiative (IVI) Field Operational Test (FOT) documents the goals and objectives, research approach, methods, and findings of a program to measure the feasib...

  14. Using SPMDs To Assess Natural Recovery Of PCB-Contaminated Sediments In Lake Hartwell, SC: I. A Field Test Of New In-Situ Deployment Methods

    EPA Science Inventory

    Results from the field testing of some innovative sampling methods developed to evaluate risk management strategies for polychlorinated biphenyl (PCB) contaminated sediments are presented. Semipermeable membrane devices (SPMDs) were combined with novel deployment methods to quan...

  15. Sheet metals characterization using the virtual fields method

    NASA Astrophysics Data System (ADS)

    Marek, Aleksander; Davis, Frances M.; Pierron, Fabrice

    2018-05-01

    In this work, a characterisation method involving a deep-notched specimen subjected to a tensile loading is introduced. This specimen leads to heterogeneous states of stress and strain, the latter being measured using a stereo DIC system (MatchID). This heterogeneity enables the identification of multiple material parameters in a single test. In order to identify material parameters from the DIC data, an inverse method called the Virtual Fields Method is employed. The method combined with recently developed sensitivity-based virtual fields allows to optimally locate areas in the test where information about each material parameter is encoded, improving accuracy of the identification over the traditional user-defined virtual fields. It is shown that a single test performed at 45° to the rolling direction is sufficient to obtain all anisotropic plastic parameters, thus reducing experimental effort involved in characterisation. The paper presents the methodology and some numerical validation.

  16. FUELS IN SOIL TEST KIT: FIELD USE OF DIESEL DOG SOIL TEST KITS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Susan S. Sorini; John F. Schabron; Joseph F. Rovani, Jr.

    Western Research Institute (WRI) has developed a new commercial product ready for technology transfer, the Diesel Dog{reg_sign} Portable Soil Test Kit, for performing analysis of fuel-contaminated soils in the field. The technology consists of a method developed by WRI (U.S. Patents 5,561,065 and 5,976,883) and hardware developed by WRI that allows the method to be performed in the field (patent pending). The method is very simple and does not require the use of highly toxic reagents. The aromatic components in a soil extract are measured by absorption at 254 nm with a field-portable photometer. WRI added significant value to themore » technology by taking the method through the American Society for Testing and Materials (ASTM) approval and validation processes. The method is designated as ASTM Method D 5831-96, Standard Test Method for Screening Fuels in Soils. This ASTM designation allows the method to be used for federal compliance activities. In June 2001, the Diesel Dog technology won an American Chemical Society Regional Industrial Innovations Award. To gain field experience with the new technology, Diesel Dog kits have been used for a variety of site evaluation and cleanup activities. Information gained from these activities has led to improvements in hardware configurations and additional insight into correlating Diesel Dog results with results from laboratory methods. The Wyoming Department of Environmental Quality (DEQ) used Diesel Dog Soil Test Kits to guide cleanups at a variety of sites throughout the state. ENSR, of Acton, Massachusetts, used a Diesel Dog Portable Soil Test Kit to evaluate sites in the Virgin Islands and Georgia. ChemTrack and the U.S. Army Corps of Engineers successfully used a test kit to guide excavation at an abandoned FAA fuel-contaminated site near Fairbanks, Alaska. Barenco, Inc. is using a Diesel Dog Portable Soil Test Kit for site evaluations in Canada. A small spill of diesel fuel was cleaned up in Laramie, Wyoming using a Diesel Dog Soil Test Kit.« less

  17. Comparison of methods for in vitro testing of susceptibility of porcine Mycoplasma species to antimicrobial agents.

    PubMed

    Ter Laak, E A; Pijpers, A; Noordergraaf, J H; Schoevers, E C; Verheijden, J H

    1991-02-01

    The MICs of 18 antimicrobial agents used against strains of three porcine Mycoplasma species were determined by a serial broth dilution method. Twenty field strains of M. hyorhinis, ten field strains of M. hyopneumoniae, six field strains of M. flocculare, and the type strains of these species were tested. Twelve field strains and the type strain of M. hyorhinis were also tested by an agar dilution method. Tests were read at various time points. When the broth dilution method was used, the final MIC had to be read 2 days after color changes had stopped. MICs of tetracycline, oxytetracycline, doxycycline, and minocycline were low for the three Mycoplasma species tested. MICs of chlortetracycline were 8 to 16 times higher than MICs of the other tetracyclines. Spiramycin, tylosin, kitasamycin, spectinomycin, tiamulin, lincomycin, and clindamycin were effective against all strains of M. hyorhinis and M. hyopneumoniae. The quinolones were highly effective against M. hyopneumoniae but less effective against M. hyorhinis. The susceptibility patterns for M. hyopneumoniae and M. flocculare were similar.

  18. Comparison of methods for in vitro testing of susceptibility of porcine Mycoplasma species to antimicrobial agents.

    PubMed Central

    Ter Laak, E A; Pijpers, A; Noordergraaf, J H; Schoevers, E C; Verheijden, J H

    1991-01-01

    The MICs of 18 antimicrobial agents used against strains of three porcine Mycoplasma species were determined by a serial broth dilution method. Twenty field strains of M. hyorhinis, ten field strains of M. hyopneumoniae, six field strains of M. flocculare, and the type strains of these species were tested. Twelve field strains and the type strain of M. hyorhinis were also tested by an agar dilution method. Tests were read at various time points. When the broth dilution method was used, the final MIC had to be read 2 days after color changes had stopped. MICs of tetracycline, oxytetracycline, doxycycline, and minocycline were low for the three Mycoplasma species tested. MICs of chlortetracycline were 8 to 16 times higher than MICs of the other tetracyclines. Spiramycin, tylosin, kitasamycin, spectinomycin, tiamulin, lincomycin, and clindamycin were effective against all strains of M. hyorhinis and M. hyopneumoniae. The quinolones were highly effective against M. hyopneumoniae but less effective against M. hyorhinis. The susceptibility patterns for M. hyopneumoniae and M. flocculare were similar. PMID:2024954

  19. Predicting moisture-induced damage to asphaltic concrete : field evaluation phase, interim report.

    DOT National Transportation Integrated Search

    1977-01-01

    Virginia is one of seven state and federal agencies participating in a field evaluation of a stripping test method developed under NCHRP Project 4-8 (3), "Predicting Moisture- Induced Damage to Asphaltic Concrete." The test method is being used to ev...

  20. SMART empirical approaches for predicting field performance of PV modules from results of reliability tests

    NASA Astrophysics Data System (ADS)

    Hardikar, Kedar Y.; Liu, Bill J. J.; Bheemreddy, Venkata

    2016-09-01

    Gaining an understanding of degradation mechanisms and their characterization are critical in developing relevant accelerated tests to ensure PV module performance warranty over a typical lifetime of 25 years. As newer technologies are adapted for PV, including new PV cell technologies, new packaging materials, and newer product designs, the availability of field data over extended periods of time for product performance assessment cannot be expected within the typical timeframe for business decisions. In this work, to enable product design decisions and product performance assessment for PV modules utilizing newer technologies, Simulation and Mechanism based Accelerated Reliability Testing (SMART) methodology and empirical approaches to predict field performance from accelerated test results are presented. The method is demonstrated for field life assessment of flexible PV modules based on degradation mechanisms observed in two accelerated tests, namely, Damp Heat and Thermal Cycling. The method is based on design of accelerated testing scheme with the intent to develop relevant acceleration factor models. The acceleration factor model is validated by extensive reliability testing under different conditions going beyond the established certification standards. Once the acceleration factor model is validated for the test matrix a modeling scheme is developed to predict field performance from results of accelerated testing for particular failure modes of interest. Further refinement of the model can continue as more field data becomes available. While the demonstration of the method in this work is for thin film flexible PV modules, the framework and methodology can be adapted to other PV products.

  1. Rapid high temperature field test method for evaluation of geothermal calcite scale inhibitors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Asperger, R.G.

    1982-08-01

    A test method is described which allows the rapid field testing of calcite scale inhibitors in high- temperature geothermal brines. Five commercial formulations, chosen on the basis of laboratory screening tests, were tested in brines with low total dissolved solids at ca 500 F. Four were found to be effective; of these, 2 were found to be capable of removing recently deposited scale. One chemical was tested in the full-flow brine line for 6 wks. It was shown to stop a severe surface scaling problem at the well's control valve, thus proving the viability of the rapid test method. (12more » refs.)« less

  2. EPA flow reference method testing and analysis: Data report -- Pennsylvania Electric Company, G.P.U. Genco Homer City Station. Volume 1: Test description and appendix A (data distribution package)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-09-01

    This report describes the test site, equipment, and procedures and presents the data obtained during field testing at G.P.U. Genco Homer City Station, August 19--24, 1997. This was the third of three field tests that the US Environmental Protection Agency (EPA) conducted in 1997 as part of a major study to evaluate potential improvements to Method 3, EPA`s test method for measuring flue gas volumetric flow in stacks. The report also includes a Data Distribution Package, the official, complete repository of the results obtained at the test site.

  3. Rapid, high-temperature, field test method for evaluation of geothermal calcium carbonate scale inhibitors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Asperger, R.G.

    1986-09-01

    A new test method is described that allows the rapid field testing of calcium carbonate scale inhibitors at 500/sup 0/F (260/sup 0/C). The method evolved from use of a full-flow test loop on a well with a mass flow rate of about 1 x 10/sup 6/ lbm/hr (126 kg/s). It is a simple, effective way to evaluate the effectiveness of inhibitors under field conditions. Five commercial formulations were chosen for field evaluation on the basis of nonflowing, laboratory screening tests at 500/sup 0/F (260/sup 0/C). Four of these formulations from different suppliers controlled calcium carbonate scale deposition as measured bymore » the test method. Two of these could dislodge recently deposited scale that had not age-hardened. Performance-profile diagrams, which were measured for these four effective inhibitors, show the concentration interrelationship between brine calcium and inhibitor concentrations at which the formulations will and will not stop scale formation in the test apparatus. With these diagrams, one formulation was chosen for testing on the full-flow brine line. The composition was tested for 6 weeks and showed a dramatic decrease in the scaling occurring at the flow-control valve. This scaling was about to force a shutdown of a major, long-term flow test being done for reservoir economic evaluations. The inhibitor stopped the scaling, and the test was performed without interruption.« less

  4. Open-field test site

    NASA Astrophysics Data System (ADS)

    Gyoda, Koichi; Shinozuka, Takashi

    1995-06-01

    An open-field test site with measurement equipment, a turn table, antenna positioners, and measurement auxiliary equipment was remodelled at the CRL north-site. This paper introduces the configuration, specifications and characteristics of this new open-field test site. Measured 3-m and 10-m site attenuations are in good agreement with theoretical values, and this means that this site is suitable for using 3-m and 10-m method EMI/EMC measurements. The site is expected to be effective for antenna measurement, antenna calibration, and studies on EMI/EMC measurement methods.

  5. Why the Major Field Test in Business Does Not Report Subscores: Reliability and Construct Validity Evidence. Research Report. ETS RR-12-11

    ERIC Educational Resources Information Center

    Ling, Guangming

    2012-01-01

    To assess the value of individual students' subscores on the Major Field Test in Business (MFT Business), I examined the test's internal structure with factor analysis and structural equation model methods, and analyzed the subscore reliabilities using the augmented scores method. Analyses of the internal structure suggested that the MFT Business…

  6. Examination of the Structural Response of the Orion European Service Module to Reverberant and Direct Field Acoustic Testing

    NASA Technical Reports Server (NTRS)

    McNelis, Mark E.; Hughes, William O.; Larko, Jeffrey M.; Bittinger, Samantha A.; Le-Plenier, Cyprien; Fogt, Vincent A.; Ngan, Ivan; Thirkettle, Anthony C.; Skinner, Mitch; Larkin, Paul

    2017-01-01

    The NASA Orion Multi-Purpose Crew Vehicle (MPCV), comprised of the Service Module, the Crew Module, and the Launch Abort System, is the next generation human spacecraft designed and built for deep space exploration. Orion will launch on NASAs new heavy-lift rocket, the Space Launch System. The European Space Agency (ESA) is responsible for providing the propulsion sub-assembly of the Service Module to NASA, called the European Service Module (ESM). The ESM is being designed and built by Airbus Safran Launchers for ESA. Traditionally, NASA has utilized reverberant acoustic testing for qualification of spaceflight hardware. The ESM Structural Test Article (E-STA) was tested at the NASA Plum Brook Stations (PBS) Reverberant Acoustic Test Facility in April-May 2016. However, Orion is evaluating an alternative acoustic test method, using direct field acoustic excitation, for the MPCVs Service Module and Crew Module. Lockheed Martin is responsible for the Orion proof-of-concept direct field acoustic test program. The E-STA was exposed to direct field acoustic testing at NASA PBS in February 2017. This paper compares the dynamic response of the E-STA structure and its components to both the reverberant and direct field acoustic test excitations. Advantages and disadvantages of direct field acoustic test excitation method are discussed.

  7. NON-DESTRUCTIVE METHOD AND MEANS FOR FLAW DETECTION

    DOEpatents

    Hochschild, R.

    1959-03-10

    BS>An improved method is presented for the nondestructive detection of flaws in olectrictilly conductivc articles using magnetic field. According to thc method a homogoneous mignetic field is established in the test article;it right angle" to the artyicle. A probe is aligned with its axis transverse to the translates so hat th4 probe scans the surface of the test article while the axis of the robe is transverse to the direction of translation of the article. In this manner any output current obtained in thc probe is an indication of the size and location of a flaw in the article under test, with a miiiimum of signal pick- up in the probe from the established magnetic field.

  8. Traditional use of indigenous mosquito-repellents to protect humans against mosquitoes and other insect bites in a rural community of Cameroon.

    PubMed

    Ntonifor, N N; Ngufor, C A; Kimbi, H K; Oben, B O

    2006-10-01

    To document and test the efficacy of indigenous traditional personal protection methods against mosquito bites and general nuisance. A prospective study based on a survey and field evaluation of selected plant-based personal protection methods against mosquito bites. Bolifamba, a rural setting of the Mount Cameroon region. A structured questionnaire was administered to 179 respondents and two anti-mosquito measures were tested under field conditions. Identified traditional anti-mosquito methods used by indigenes of Bolifamba. Two plants tested under field conditions were found to be effective. Of the 179 respondents, 88 (49.16%) used traditional anti-mosquito methods; 57 (64.77%) used plant-based methods while 31 (35.2%) used various petroleum oils. The rest of the respondents, 91 (50.8%) used conventional personal protection methods. Reasons for using traditional methods were because they were available, affordable and lack of known more effective alternatives. The demerits of these methods were: labourious to implement, stain dresses, produce a lot of smoke/ repulsive odours when used; those of conventional methods were lack of adequate information about them, high cost and non-availability. When the two most frequently used plants, Saccharum officinarium and Ocimum basilicum were evaluated under field conditions, each gave a better protection than the control. Most plants used against mosquitoes in the area are known potent mosquito repellents but others identified in the study warrant further research. The two tested under field conditions were effective though less than the commonly used commercial diethyltoluamide.

  9. SU-F-T-423: Automating Treatment Planning for Cervical Cancer in Low- and Middle- Income Countries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kisling, K; Zhang, L; Yang, J

    Purpose: To develop and test two independent algorithms that automatically create the photon treatment fields for a four-field box beam arrangement, a common treatment technique for cervical cancer in low- and middle-income countries. Methods: Two algorithms were developed and integrated into Eclipse using its Advanced Programming Interface:3D Method: We automatically segment bony anatomy on CT using an in-house multi-atlas contouring tool and project the structures into the beam’s-eye-view. We identify anatomical landmarks on the projections to define the field apertures. 2D Method: We generate DRRs for all four beams. An atlas of DRRs for six standard patients with corresponding fieldmore » apertures are deformably registered to the test patient DRRs. The set of deformed atlas apertures are fitted to an expected shape to define the final apertures. Both algorithms were tested on 39 patient CTs, and the resulting treatment fields were scored by a radiation oncologist. We also investigated the feasibility of using one algorithm as an independent check of the other algorithm. Results: 96% of the 3D-Method-generated fields and 79% of the 2D-method-generated fields were scored acceptable for treatment (“Per Protocol” or “Acceptable Variation”). The 3D Method generated more fields scored “Per Protocol” than the 2D Method (62% versus 17%). The 4% of the 3D-Method-generated fields that were scored “Unacceptable Deviation” were all due to an improper L5 vertebra contour resulting in an unacceptable superior jaw position. When these same patients were planned with the 2D method, the superior jaw was acceptable, suggesting that the 2D method can be used to independently check the 3D method. Conclusion: Our results show that our 3D Method is feasible for automatically generating cervical treatment fields. Furthermore, the 2D Method can serve as an automatic, independent check of the automatically-generated treatment fields. These algorithms will be implemented for fully automated cervical treatment planning.« less

  10. Field analysis for explosives: TNT and RDX

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elcoate, W.; Mapes, J.

    The EPA has listed as hazardous many of the compounds used in the production of ammunitions and other explosive ordnance. The contamination of soil with TNT (2,4,6-trinitrotoluene), the major component of many munitions formulations and to a lesser degree RDX (hexhydro-1,3,5-trinitro-1,3,5-trizine) is a significant problem at many ammunition manufacturing facilities, depots, and ordnance disposal sites. Field test kits for explosives TNT and RDX (hexhydro-1,3,5-trinitro-1,3,5-triazine) were developed based on the methods of T.F. Jenkins and M.E. Walsh and T.F Jenkins. EnSys Environmental Products, Inc. with technical support from T.F. Jenkins took the original TNT procedure, modified it for easier field use,more » performed validation studies to ensure that it met or exceeded the method specifications for both the T.F. Jenkins and SW-846 methods, and developed an easy to use test format for the field testing of TNT. The RDX procedure has gone through the development cycle and is presently in the field validation phase. This paper describes the test protocol and performance characteristics of the TNT test procedure.« less

  11. 29 CFR 1926.752 - Site layout, site-specific erection plan and construction sequence.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... standard test method of field-cured samples, either 75 percent of the intended minimum compressive design... the basis of an appropriate ASTM standard test method of field-cured samples, either 75 percent of the intended minimum compressive design strength or sufficient strength to support the loads imposed during...

  12. 29 CFR 1926.752 - Site layout, site-specific erection plan and construction sequence.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... standard test method of field-cured samples, either 75 percent of the intended minimum compressive design... the basis of an appropriate ASTM standard test method of field-cured samples, either 75 percent of the intended minimum compressive design strength or sufficient strength to support the loads imposed during...

  13. 29 CFR 1926.752 - Site layout, site-specific erection plan and construction sequence.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... standard test method of field-cured samples, either 75 percent of the intended minimum compressive design... the basis of an appropriate ASTM standard test method of field-cured samples, either 75 percent of the intended minimum compressive design strength or sufficient strength to support the loads imposed during...

  14. 29 CFR 1926.752 - Site layout, site-specific erection plan and construction sequence.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... standard test method of field-cured samples, either 75 percent of the intended minimum compressive design... the basis of an appropriate ASTM standard test method of field-cured samples, either 75 percent of the intended minimum compressive design strength or sufficient strength to support the loads imposed during...

  15. 29 CFR 1926.752 - Site layout, site-specific erection plan and construction sequence.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... standard test method of field-cured samples, either 75 percent of the intended minimum compressive design... the basis of an appropriate ASTM standard test method of field-cured samples, either 75 percent of the intended minimum compressive design strength or sufficient strength to support the loads imposed during...

  16. Verification of a ground-based method for simulating high-altitude, supersonic flight conditions

    NASA Astrophysics Data System (ADS)

    Zhou, Xuewen; Xu, Jian; Lv, Shuiyan

    Ground-based methods for accurately representing high-altitude, high-speed flight conditions have been an important research topic in the aerospace field. Based on an analysis of the requirements for high-altitude supersonic flight tests, a ground-based test bed was designed combining Laval nozzle, which is often found in wind tunnels, with a rocket sled system. Sled tests were used to verify the performance of the test bed. The test results indicated that the test bed produced a uniform-flow field with a static pressure and density equivalent to atmospheric conditions at an altitude of 13-15km and at a flow velocity of approximately M 2.4. This test method has the advantages of accuracy, fewer experimental limitations, and reusability.

  17. Vadose Zone Transport Field Study: Detailed Test Plan for Simulated Leak Tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ward, Anderson L.; Gee, Glendon W.

    2000-06-23

    This report describes controlled transport experiments at well-instrumented field tests to be conducted during FY 2000 in support of DOE?s Vadose Zone Transport Field Study (VZTFS). The VZTFS supports the Groundwater/Vadose Zone Integration Project Science and Technology Initiative. The field tests will improve understanding of field-scale transport and lead to the development or identification of efficient and cost-effective characterization methods. These methods will capture the extent of contaminant plumes using existing steel-cased boreholes. Specific objectives are to 1) identify mechanisms controlling transport processes in soils typical of the hydrogeologic conditions of Hanford?s waste disposal sites; 2) reduce uncertainty in conceptualmore » models; 3) develop a detailed and accurate data base of hydraulic and transport parameters for validation of three-dimensional numerical models; and 4) identify and evaluate advanced, cost-effective characterization methods with the potential to assess changing conditions in the vadose zone, particularly as surrogates of currently undetectable high-risk contaminants. Pacific Northwest National Laboratory (PNNL) manages the VZTFS for DOE.« less

  18. TEST METHODS TO DETERMINE THE MERCURY EMISSIONS FROM SLUDGE INCINERATION PLANTS

    EPA Science Inventory

    Two test methods for mercury are described along with the laboratory and field studies done in developing and validating them. One method describes how to homogenize and analyze large quantities of sewage sludge. The other test method describes how to measure the mercury emission...

  19. Testing Methods for Challenging the National Wetland Plant List: Using Tsuga canadensis (L.) Carr. (Eastern Hemlock) as a Case Study

    DTIC Science & Technology

    2017-07-01

    ESRI (Nature Conservancy and Environmental Systems Research Institute). 1994. Field Methods . In Field Methods for Vegetation Mapping: United States...ER D C/ CR RE L TR -1 7- 9 Wetlands Regulatory Assistance Program (WRAP) Testing Methods for Challenging the National Wetland Plant List...Robert W. Lichvar and Jennifer J. Goulet July 2017 Approved for public release; distribution is unlimited. The U.S. Army Engineer Research

  20. Modified Drop Tower Impact Tests for American Football Helmets.

    PubMed

    Rush, G Alston; Prabhu, R; Rush, Gus A; Williams, Lakiesha N; Horstemeyer, M F

    2017-02-19

    A modified National Operating Committee on Standards for Athletic Equipment (NOCSAE) test method for American football helmet drop impact test standards is presented that would provide better assessment of a helmet's on-field impact performance by including a faceguard on the helmet. In this study, a merger of faceguard and helmet test standards is proposed. The need for a more robust systematic approach to football helmet testing procedures is emphasized by comparing representative results of the Head Injury Criterion (HIC), Severity Index (SI), and peak acceleration values for different helmets at different helmet locations under modified NOCSAE standard drop tower tests. Essentially, these comparative drop test results revealed that the faceguard adds a stiffening kinematic constraint to the shell that lessens total energy absorption. The current NOCSAE standard test methods can be improved to represent on-field helmet hits by attaching the faceguards to helmets and by including two new helmet impact locations (Front Top and Front Top Boss). The reported football helmet test method gives a more accurate representation of a helmet's performance and its ability to mitigate on-field impacts while promoting safer football helmets.

  1. Three-Dimensional Bayesian Geostatistical Aquifer Characterization at the Hanford 300 Area using Tracer Test Data

    NASA Astrophysics Data System (ADS)

    Chen, X.; Murakami, H.; Hahn, M. S.; Hammond, G. E.; Rockhold, M. L.; Rubin, Y.

    2010-12-01

    Tracer testing under natural or forced gradient flow provides useful information for characterizing subsurface properties, by monitoring and modeling the tracer plume migration in a heterogeneous aquifer. At the Hanford 300 Area, non-reactive tracer experiments, in addition to constant-rate injection tests and electromagnetic borehole flowmeter (EBF) profiling, were conducted to characterize the heterogeneous hydraulic conductivity field. A Bayesian data assimilation technique, method of anchored distributions (MAD), is applied to assimilate the experimental tracer test data and to infer the three-dimensional heterogeneous structure of the hydraulic conductivity in the saturated zone of the Hanford formation. In this study, the prior information of the underlying random hydraulic conductivity field was obtained from previous field characterization efforts using the constant-rate injection tests and the EBF data. The posterior distribution of the random field is obtained by further conditioning the field on the temporal moments of tracer breakthrough curves at various observation wells. The parallel three-dimensional flow and transport code PFLOTRAN is implemented to cope with the highly transient flow boundary conditions at the site and to meet the computational demand of the proposed method. The validation results show that the field conditioned on the tracer test data better reproduces the tracer transport behavior compared to the field characterized previously without the tracer test data. A synthetic study proves that the proposed method can effectively assimilate tracer test data to capture the essential spatial heterogeneity of the three-dimensional hydraulic conductivity field. These characterization results will improve conceptual models developed for the site, including reactive transport models. The study successfully demonstrates the capability of MAD to assimilate multi-scale multi-type field data within a consistent Bayesian framework. The MAD framework can potentially be applied to combine geophysical data with other types of data in site characterization.

  2. Geotechnical Descriptions of Rock and Rock Masses.

    DTIC Science & Technology

    1985-04-01

    determined in the field on core speci ns by the standard Rock Testing Handbook Methods . afls GA DTIC TAB thannounod 13 Justifiatlo By Distributin...to provide rock strength descriptions from the field. The point-load test has proven to be a reliable method of determining rock strength properties...report should qualify the reported spacing values by stating the methods used to determine spacing. Preferably the report should make the determination

  3. Method matters: Understanding diagnostic reliability in DSM-IV and DSM-5.

    PubMed

    Chmielewski, Michael; Clark, Lee Anna; Bagby, R Michael; Watson, David

    2015-08-01

    Diagnostic reliability is essential for the science and practice of psychology, in part because reliability is necessary for validity. Recently, the DSM-5 field trials documented lower diagnostic reliability than past field trials and the general research literature, resulting in substantial criticism of the DSM-5 diagnostic criteria. Rather than indicating specific problems with DSM-5, however, the field trials may have revealed long-standing diagnostic issues that have been hidden due to a reliance on audio/video recordings for estimating reliability. We estimated the reliability of DSM-IV diagnoses using both the standard audio-recording method and the test-retest method used in the DSM-5 field trials, in which different clinicians conduct separate interviews. Psychiatric patients (N = 339) were diagnosed using the SCID-I/P; 218 were diagnosed a second time by an independent interviewer. Diagnostic reliability using the audio-recording method (N = 49) was "good" to "excellent" (M κ = .80) and comparable to the DSM-IV field trials estimates. Reliability using the test-retest method (N = 218) was "poor" to "fair" (M κ = .47) and similar to DSM-5 field-trials' estimates. Despite low test-retest diagnostic reliability, self-reported symptoms were highly stable. Moreover, there was no association between change in self-report and change in diagnostic status. These results demonstrate the influence of method on estimates of diagnostic reliability. (c) 2015 APA, all rights reserved).

  4. An assessment of the Nguyen and Pinder method for slug test analysis. [In situ estimates of ground water contamination

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Butler, J.J. Jr.; Hyder, Z.

    The Nguyen and Pinder method is one of four techniques commonly used for analysis of response data from slug tests. Limited field research has raised questions about the reliability of the parameter estimates obtained with this method. A theoretical evaluation of this technique reveals that errors were made in the derivation of the analytical solution upon which the technique is based. Simulation and field examples show that the errors result in parameter estimates that can differ from actual values by orders of magnitude. These findings indicate that the Nguyen and Pinder method should no longer be a tool in themore » repertoire of the field hydrogeologist. If data from a slug test performed in a partially penetrating well in a confined aquifer need to be analyzed, recent work has shown that the Hvorslev method is the best alternative among the commonly used techniques.« less

  5. Accounting for differing exposure patterns between laboratory tests and the field in the assessment of long-term risks of pesticides to terrestrial vertebrates.

    PubMed

    Fischer, David L

    2005-11-01

    Long-term risks of pesticides to birds and mammals are currently assessed by comparing effects thresholds determined in chronic laboratory studies to exposure levels expected to occur in the field. However, there is often a mismatch between exposure patterns tested in the laboratory tests (exposure levels held constant) and those experienced by animals in the field (exposure levels varying over time). Three methods for addressing this problem are presented and discussed. Time-weighted averaging (TWA) converts a variable field exposure regime to a single value that can be compared directly to the laboratory test results. Body-burden modeling (BBM) is applied to both laboratory and field exposure regimes allowing a straightforward comparison of body residue levels expected for each situation. Temporal analysis (TA) uses expert judgment to decide if the length of time exposure exceeds a toxicity threshold is long enough to cause biologically significant effects. To reduce uncertainty in long-term assessments, the conduct of specialized laboratory tests in which test subjects are administered a time-varying exposure that mimics what occurs in the field should be considered. Such tests may also be useful testing the validity of each of these assessment methods.

  6. Applicability of ELISA-based Determination of Pesticides for Groundwater Quality Monitoring

    NASA Astrophysics Data System (ADS)

    Tsuchihara, Takeo; Yoshimoto, Shuhei; Ishida, Satoshi; Imaizumi, Masayuki

    The principals and procedures of ELISA (Enzyme-linked Immunosorbent Assay)-based determination of pesticides (Fenitrothion) in environmental samples were reviewed, and the applicability of the ELISA method for groundwater quality monitoring were validated through the experimental tracer tests in soil columns and the field test in Okinoerabu Island. The test results showed that the ELISA method could be useful not only for screening but also for quantitative analysis of pesticides. In the experimental tracer tests in soil columns, the retardation of pesticides leaching compared with conservative tracers were observed. In the field test, the contamination of the pesticide was detected in groundwater samples in Okinoerabu Island, even though the targeted pesticide was considered to be applied to the upland field 4 months ago. In order to investigate the transport and fate of pesticides in groundwater taking into account retardation from the field to groundwater table and the residue in groundwater, continuous observations of pesticides in groundwater are in a strong need, and the ELISA method is applicable to the long-term quality groundwater monitoring.

  7. Measuring Extinction in Local Group Galaxies Using Background Galaxies

    NASA Astrophysics Data System (ADS)

    Wyder, T. K.; Hodge, P. W.

    1999-05-01

    Knowledge of the distribution and quantity of dust in galaxies is important for understanding their structure and evolution. The goal of our research is to measure the total extinction through Local Group galaxies using measured properties of background galaxies. Our method relies on the SExtractor software as an objective and automated method of detecting background galaxies. In an initial test, we have explored two WFPC2 fields in the SMC and two in M31 obtained from the HST archives. The two pointings in the SMC are fields around the open clusters L31 and B83 while the two M31 fields target the globular clusters G1 and G170. Except for the G1 observations of M31, the fields chosen are very crowded (even when observed with HST) and we chose them as a particularly stringent test of the method. We performed several experiments using a series of completeness tests that involved superimposing comparison fields, adjusted to the equivalent exposure time, from the HST Medium-Deep and Groth-Westphal surveys. These tests showed that for crowded fields, such as the two in the core of the SMC and the one in the bulge of M31, this automated method of detecting galaxies can be completely dominated by the effects of crowding. For these fields, only a small fraction of the added galaxies was recovered. However, in the outlying G1 field in M31, almost all of the added galaxies were recovered. The numbers of actual background galaxies in this field are consistent with zero extinction. As a follow-up experiment, we used image processing techniques to suppress stellar objects while enhancing objects with non-stellar, more gradual luminosity profiles. This method yielded significant numbers of background galaxies in even the most crowded fields, which we are now analyzing to determine the total extinction and reddening caused by the foreground galaxy.

  8. Functional Assessment-Based Interventions for Students with or At-Risk for High-Incidence Disabilities: Field Testing Single-Case Synthesis Methods

    ERIC Educational Resources Information Center

    Common, Eric Alan; Lane, Kathleen Lynne; Pustejovsky, James E.; Johnson, Austin H.; Johl, Liane Elizabeth

    2017-01-01

    This systematic review investigated one systematic approach to designing, implementing, and evaluating functional assessment-based interventions (FABI) for use in supporting school-age students with or at-risk for high-incidence disabilities. We field tested several recently developed methods for single-case design syntheses. First, we appraised…

  9. Repeatability and validity of a field kit for estimation of cholinesterase in whole blood.

    PubMed Central

    London, L; Thompson, M L; Sacks, S; Fuller, B; Bachmann, O M; Myers, J E

    1995-01-01

    OBJECTIVES--To evaluate a spectrophotometric field kit (Test-Mate-OP) for repeatability and validity in comparison with reference laboratory methods and to model its anticipated sensitivity and specificity based on these findings. METHODS--76 farm workers between the age of 20 and 55, of whom 30 were pesticide applicators exposed to a range of organophosphates in the preceding 10 days, had blood taken for plasma cholinesterase (PCE) and erythrocyte cholinesterase (ECE) measurement by field kit or laboratory methods. Paired blinded duplicate samples were taken from subgroups in the sample to assess repeatability of laboratory and field kit methods. Field kits were also used to test venous blood in one subgroup. The variance obtained for the field kit tests was then applied to two hypothetical scenarios that used published action guidelines to model the kit's sensitivity and specificity. RESULTS--Repeatability for PCE was much poorer and for ECE slightly poorer than that of laboratory measures. A substantial upward bias for field kit ECE relative to laboratory measurements was found. Sensitivity of the kit to a 40% drop in PCE was 67%, whereas that for ECE was 89%. Specificity of the kit with no change in mean of the population was 100% for ECE and 91% for PCE. CONCLUSION--Field kit ECE estimation seems to be sufficiently repeatable for surveillance activities, whereas PCE does not. Repeatability of both tests seems to be too low for use in epidemiological dose-response investigations. Further research is indicated to characterise the upward bias in ECE estimation on the kit. PMID:7697143

  10. Magnetic dipole moment determination by near-field analysis

    NASA Technical Reports Server (NTRS)

    Eichhorn, W. L.

    1972-01-01

    A method for determining the magnetic moment of a spacecraft from magnetic field data taken in a limited region of space close to the spacecraft. The spacecraft's magnetic field equations are derived from first principles. With measurements of this field restricted to certain points in space, the near-field equations for the spacecraft are derived. These equations are solved for the dipole moment by a least squares procedure. A method by which one can estimate the magnitude of the error in the calculations is also presented. This technique was thoroughly tested on a computer. The test program is described and evaluated, and partial results are presented.

  11. Dynamic Test Method Based on Strong Electromagnetic Pulse for Electromagnetic Shielding Materials with Field-Induced Insulator-Conductor Phase Transition

    NASA Astrophysics Data System (ADS)

    Wang, Yun; Zhao, Min; Wang, Qingguo

    2018-01-01

    In order to measure the pulse shielding performance of materials with the characteristic of field-induced insulator-conductor phase transition when materials are used for electromagnetic shielding, a dynamic test method was proposed based on a coaxial fixture. Experiment system was built by square pulse source, coaxial cable, coaxial fixture, attenuator, and oscilloscope and insulating components. S11 parameter of the test system was obtained, which suggested that the working frequency ranges from 300 KHz to 7.36 GHz. Insulating performance is good enough to avoid discharge between conductors when material samples is exposed in the strong electromagnetic pulse field up to 831 kV/m. This method is suitable for materials with annular shape, certain thickness and the characteristic of field-induced insulator-conductor phase transition to get their shielding performances of strong electromagnetic pulse.

  12. Field demonstration of on-site analytical methods for TNT and RDX in ground water

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Craig, H.; Ferguson, G.; Markos, A.

    1996-12-31

    A field demonstration was conducted to assess the performance of eight commercially-available and emerging colorimetric, immunoassay, and biosensor on-site analytical methods for explosives 2,4,6-trinitrotoluene (TNT) and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) in ground water and leachate at the Umatilla Army Depot Activity, Hermiston, Oregon and US Naval Submarine Base, Bangor, Washington, Superfund sites. Ground water samples were analyzed by each of the on-site methods and results compared to laboratory analysis using high performance liquid chromatography (HPLC) with EPA SW-846 Method 8330. The commercial methods evaluated include the EnSys, Inc., TNT and RDX colorimetric test kits (EPA SW-846 Methods 8515 and 8510) with amore » solid phase extraction (SPE) step, the DTECH/EM Science TNT and RDX immunoassay test kits (EPA SW-846 Methods 4050 and 4051), and the Ohmicron TNT immunoassay test kit. The emerging methods tested include the antibody-based Naval Research Laboratory (NRL) Continuous Flow Immunosensor (CFI) for TNT and RDX, and the Fiber Optic Biosensor (FOB) for TNT. Accuracy of the on-site methods were evaluated using linear regression analysis and relative percent difference (RPD) comparison criteria. Over the range of conditions tested, the colorimetric methods for TNT and RDX showed the highest accuracy of the emerging methods for TNT and RDX. The colorimetric method was selected for routine ground water monitoring at the Umatilla site, and further field testing on the NRL CFI and FOB biosensors will continue at both Superfund sites.« less

  13. Simple, Low-Cost Data Collection Methods for Agricultural Field Studies.

    ERIC Educational Resources Information Center

    Koenig, Richard T.; Winger, Marlon; Kitchen, Boyd

    2000-01-01

    Summarizes relatively simple and inexpensive methods for collecting data from agricultural field studies. Describes methods involving on-farm testing, crop yield measurement, quality evaluations, weed control effectiveness, plant nutrient status, and other measures. Contains 29 references illustrating how these methods were used to conduct…

  14. Comparative evaluation of subgrade resilient modulus from non-destructive, in-situ, and laboratory methods.

    DOT National Transportation Integrated Search

    2007-08-01

    Field and laboratory testing programs were conducted to develop models that predict the resilient modulus of subgrade soils from : the test results of DCP, CIMCPT, FWD, Dynaflect, and soil properties. The field testing program included DCP, CIMCPT, F...

  15. Towards standardized assessment of endoscope optical performance: geometric distortion

    NASA Astrophysics Data System (ADS)

    Wang, Quanzeng; Desai, Viraj N.; Ngo, Ying Z.; Cheng, Wei-Chung; Pfefer, Joshua

    2013-12-01

    Technological advances in endoscopes, such as capsule, ultrathin and disposable devices, promise significant improvements in safety, clinical effectiveness and patient acceptance. Unfortunately, the industry lacks test methods for preclinical evaluation of key optical performance characteristics (OPCs) of endoscopic devices that are quantitative, objective and well-validated. As a result, it is difficult for researchers and developers to compare image quality and evaluate equivalence to, or improvement upon, prior technologies. While endoscope OPCs include resolution, field of view, and depth of field, among others, our focus in this paper is geometric image distortion. We reviewed specific test methods for distortion and then developed an objective, quantitative test method based on well-defined experimental and data processing steps to evaluate radial distortion in the full field of view of an endoscopic imaging system. Our measurements and analyses showed that a second-degree polynomial equation could well describe the radial distortion curve of a traditional endoscope. The distortion evaluation method was effective for correcting the image and can be used to explain other widely accepted evaluation methods such as picture height distortion. Development of consensus standards based on promising test methods for image quality assessment, such as the method studied here, will facilitate clinical implementation of innovative endoscopic devices.

  16. Exact Green's function method of solar force-free magnetic-field computations with constant alpha. I - Theory and basic test cases

    NASA Technical Reports Server (NTRS)

    Chiu, Y. T.; Hilton, H. H.

    1977-01-01

    Exact closed-form solutions to the solar force-free magnetic-field boundary-value problem are obtained for constant alpha in Cartesian geometry by a Green's function approach. The uniqueness of the physical problem is discussed. Application of the exact results to practical solar magnetic-field calculations is free of series truncation errors and is at least as economical as the approximate methods currently in use. Results of some test cases are presented.

  17. Development of radon-222 as a natural tracer for monitoring the remediation of NAPL contamination in the subsurface. 1998 annual progress report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Semprini, L.; Istok, J.

    'The objective of this research is to develop a unique method of using naturally occurring radon-222 as a tracer for locating and quantitatively describing the presence of subsurface NAPL contamination. The research will evaluate using radon as an inexpensive, yet highly accurate, means of detecting NAPL contamination and assessing the effectiveness of NAPL remediation. Laboratory, field, and modeling studies are being performed to evaluate this technique, and to develop methods for its successful implementation in practice. This report summarizes work that has been accomplished after 1-year of a 3-year project. The research to date has included radon tracer tests inmore » physical aquifer models (PAMs) and field studies at Site 300 of the Lawrence Livermore National Laboratory, CA, and Site 100D at Hanford DOE Facility, WA. The PAM tests have evaluated the ability of radon as a tracer to monitor the remediation of TCE NAPL contamination using surfactant treatment, and oxidation with permanganate. The surfactant tests were performed in collaboration with Dr. Jack Istok and Dr. Jennifer Field and their EMSP project ``In-situ, Field-Scale Evaluation of Surfactant Enhanced DNAPL Recovery Using a Single-Well-Push-Pull Test.'''' This collaboration enabled the EMSP radon project to make rapid progress. The PAM surfactant tests were performed in a radial flow geometry to simulate the push-pull-method that is being developed for surfactant field tests. The radon tests were easily incorporated into these experiments, since they simply rely on measuring the natural radon present in the subsurface fluids. Two types of radon tests were performed: (1) static tests where radon was permitted to build-up to steady-state concentrations in the pore fluids and the groundwater concentrations were monitored, and (2) dynamic tests were the radon response during push-pull surfactant tests was measured. Both methods were found to be useful in determining how NAPL remediation was progressing.'« less

  18. Beginning Postsecondary Students Longitudinal Study First Follow-up (BPS:96/98) Field Test Report. Working Paper Series.

    ERIC Educational Resources Information Center

    Pratt, Daniel J.; Wine, Jennifer S.; Heuer, Ruth E.; Whitmore, Roy W.; Kelly, Janice E.; Doherty, John M.; Simpson, Joe B.; Marti, Norma

    This report describes the methods and procedures used for the field test of the Beginning Postsecondary Students Longitudinal Study First Followup 1996-98 (BPS:96/98). Students in this survey were first interviewed during 1995 as part of the National Postsecondary Student Aid Study 1996 field test. The BPS:96/98 full-scale student sample includes…

  19. Field methods to measure surface displacement and strain with the Video Image Correlation method

    NASA Technical Reports Server (NTRS)

    Maddux, Gary A.; Horton, Charles M.; Mcneill, Stephen R.; Lansing, Matthew D.

    1994-01-01

    The objective of this project was to develop methods and application procedures to measure displacement and strain fields during the structural testing of aerospace components using paint speckle in conjunction with the Video Image Correlation (VIC) system.

  20. FUELS IN SOIL TEST KIT: FIELD USE OF DIESEL DOG SOIL TEST KITS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Unknown

    2001-05-31

    Western Research Institute (WRI) is commercializing Diesel Dog Portable Soil Test Kits for performing analysis of fuel-contaminated soils in the field. The technology consists of a method developed by WRI (U.S. Patents 5,561,065 and 5,976,883) and hardware developed by WRI that allows the method to be performed in the field (patent pending). The method is very simple and does not require the use of highly toxic reagents. The aromatic components in a soil extract are measured by absorption at 254 nm with a field-portable photometer. WRI added significant value to the technology by taking the method through the American Societymore » for Testing and Materials (ASTM) approval and validation processes. The method is designated ASTM Method D-5831-96, Standard Test Method for Screening Fuels in Soils. This ASTM designation allows the method to be used for federal compliance activities. In FY 99, twenty-five preproduction kits were successfully constructed in cooperation with CF Electronics, Inc., of Laramie, Wyoming. The kit components work well and the kits are fully operational. In the calendar year 2000, kits were provided to the following entities who agreed to participate as FY 99 and FY 00 JSR (Jointly Sponsored Research) cosponsors and use the kits as opportunities arose for field site work: Wyoming Department of Environmental Quality (DEQ) (3 units), F.E. Warren Air Force Base, Gradient Corporation, The Johnson Company (2 units), IT Corporation (2 units), TRC Environmental Corporation, Stone Environmental, ENSR, Action Environmental, Laco Associates, Barenco, Brown and Caldwell, Dames and Moore Lebron LLP, Phillips Petroleum, GeoSyntek, and the State of New Mexico. By early 2001, ten kits had been returned to WRI following the six-month evaluation period. On return, the components of all ten kits were fully functional. The kits were upgraded with circuit modifications, new polyethylene foam inserts, and updated instruction manuals.« less

  1. Rapid assessment of rice seed availability for wildlife in harvested fields

    USGS Publications Warehouse

    Halstead, B.J.; Miller, M.R.; Casazza, Michael L.; Coates, P.S.; Farinha, M.A.; Benjamin, Gustafson K.; Yee, J.L.; Fleskes, J.P.

    2011-01-01

    Rice seed remaining in commercial fields after harvest (waste rice) is a critical food resource for wintering waterfowl in rice-growing regions of North America. Accurate and precise estimates of the seed mass density of waste rice are essential for planning waterfowl wintering habitat extents and management. In the Sacramento Valley of California, USA, the existing method for obtaining estimates of availability of waste rice in harvested fields produces relatively precise estimates, but the labor-, time-, and machineryintensive process is not practical for routine assessments needed to examine long-term trends in waste rice availability. We tested several experimental methods designed to rapidly derive estimates that would not be burdened with disadvantages of the existing method. We first conducted a simulation study of the efficiency of each method and then conducted field tests. For each approach, methods did not vary in root mean squared error, although some methods did exhibit bias for both simulations and field tests. Methods also varied substantially in the time to conduct each sample and in the number of samples required to detect a standard trend. Overall, modified line-intercept methods performed well for estimating the density of rice seeds. Waste rice in the straw, although not measured directly, can be accounted for by a positive relationship with density of rice on the ground. Rapid assessment of food availability is a useful tool to help waterfowl managers establish and implement wetland restoration and agricultural habitat-enhancement goals for wintering waterfowl. ?? 2011 The Wildlife Society.

  2. Comparison of on-site field measured inorganic arsenic in rice with laboratory measurements using a field deployable method: Method validation.

    PubMed

    Mlangeni, Angstone Thembachako; Vecchi, Valeria; Norton, Gareth J; Raab, Andrea; Krupp, Eva M; Feldmann, Joerg

    2018-10-15

    A commercial arsenic field kit designed to measure inorganic arsenic (iAs) in water was modified into a field deployable method (FDM) to measure iAs in rice. While the method has been validated to give precise and accurate results in the laboratory, its on-site field performance has not been evaluated. This study was designed to test the method on-site in Malawi in order to evaluate its accuracy and precision in determination of iAs on-site by comparing with a validated reference method and giving original data on inorganic arsenic in Malawian rice and rice-based products. The method was validated by using the established laboratory-based HPLC-ICPMS. Statistical tests indicated there were no significant differences between on-site and laboratory iAs measurements determined using the FDM (p = 0.263, ά = 0.05) and between on-site measurements and measurements determined using HPLC-ICP-MS (p = 0.299, ά = 0.05). This method allows quick (within 1 h) and efficient screening of rice containing iAs concentrations on-site. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Oxygen uptake during functional activities after stroke—Reliability and validity of a portable ergospirometry system

    PubMed Central

    Brurok, Berit; Tjønna, Arnt Erik; Tørhaug, Tom; Askim, Torunn

    2017-01-01

    Background People with stroke have a low peak aerobic capacity and experience increased effort during performance of daily activities. The purpose of this study was to examine test-retest reliability of a portable ergospirometry system in people with stroke during performance of functional activities in a field-test. Secondary aims were to examine the proportion of oxygen consumed during the field-test in relation to the peak-test and to analyse the correlation between the oxygen uptake during the field-test and peak-test in order to support the validity of the field-test. Methods With simultaneous measurement of oxygen consumption, participants performed a standardized field-test consisting of five activities; walking over ground, stair walking, stepping over obstacles, walking slalom between cones and from a standing position lifting objects from one height to another. All activities were performed in self-selected speed. Prior to the field-test, a peak aerobic capacity test was performed. The field-test was repeated minimum 2 and maximum 14 days between the tests. ICC2,1 and Bland Altman tests (Limits of Agreement, LoA) were used to analyse test-retest reliability. Results In total 31 participants (39% women, mean (SD) age 54.5 (12.7) years and 21.1 (14.3) months’ post-stroke) were included. The ICC2,1 was ≥ 0.80 for absolute V̇O2, relative V̇O2, minute ventilation, CO2, respiratory exchange ratio, heart rate and Borgs rating of perceived exertion. ICC2,1 for total time to complete the field-test was 0.99. Mean difference in steady state V̇O2 during Test 1 and Test 2 was -0.40 (2.12) The LoAs were -3.75 and 4.51. Participants spent 60.7% of their V̇O2peak performing functional activities. Correlation between field-test and peak-test was 0.689, p = 0.001 for absolute and 0.733, p = 0.001 for relative V̇O2. Conclusions This study presents first evidence on reliability of oxygen uptake during performance of functional activities after stroke, showing very good test-retest reliability. The secondary analysis showed that the amount of energy spent during the field-test relative to the peak-test was high and the correlation between the two test was good, supporting the validity of this method. PMID:29065164

  4. Casting the Coronal Magnetic Field Reconstructions with Magnetic Field Constraints above the Photosphere in 3D Using MHD Bifrost Model

    NASA Astrophysics Data System (ADS)

    Fleishman, G. D.; Anfinogentov, S.; Loukitcheva, M.; Mysh'yakov, I.; Stupishin, A.

    2017-12-01

    Measuring and modeling coronal magnetic field, especially above active regions (ARs), remains one of the central problems of solar physics given that the solar coronal magnetism is the key driver of all solar activity. Nowadays the coronal magnetic field is often modelled using methods of nonlinear force-free field reconstruction, whose accuracy has not yet been comprehensively assessed. Given that the coronal magnetic probing is routinely unavailable, only morphological tests have been applied to evaluate performance of the reconstruction methods and a few direct tests using available semi-analytical force-free field solution. Here we report a detailed casting of various tools used for the nonlinear force-free field reconstruction, such as disambiguation methods, photospheric field preprocessing methods, and volume reconstruction methods in a 3D domain using a 3D snapshot of the publicly available full-fledged radiative MHD model. We take advantage of the fact that from the realistic MHD model we know the magnetic field vector distribution in the entire 3D domain, which enables us to perform "voxel-by-voxel" comparison of the restored magnetic field and the true magnetic field in the 3D model volume. Our tests show that the available disambiguation methods often fail at the quiet sun areas, where the magnetic structure is dominated by small-scale magnetic elements, while they work really well at the AR photosphere and (even better) chromosphere. The preprocessing of the photospheric magnetic field, although does produce a more force-free boundary condition, also results in some effective `elevation' of the magnetic field components. The effective `elevation' height turns out to be different for the longitudinal and transverse components of the magnetic field, which results in a systematic error in absolute heights in the reconstructed magnetic data cube. The extrapolation performed starting from actual AR photospheric magnetogram (i.e., without preprocessing) are free from this systematic error, while have other metrics either comparable or only marginally worse than those estimated for extrapolations from the preprocessed magnetograms. This finding favors the use of extrapolations from the original photospheric magnetogram without preprocessing.

  5. Field-based video pre-test counseling, oral testing and telephonic post-test counseling: Implementation of an HIV field testing package among high-risk Indian men

    PubMed Central

    Snyder, Hannah; Yeldandi, Vijay V.; Kumar, G. Prem; Liao, Chuanhong; Lakshmi, Vemu; Gandham, Sabitha R.; Muppudi, Uma; Oruganti, Ganesh; Schneider, John A.

    2013-01-01

    In India, men who have sex with men (MSM) and truck drivers are high-risk groups that often do not access HIV testing due to stigma and high mobility. This study evaluated a field testing package (FTP) that identified HIV positive participants through video pre-test counseling, OraQuick oral fluid HIV testing, and telephonic post-test counseling and then connected them to government facilities. 598 MSM and truck drivers participated in the FTP and completed surveys covering sociodemographics, HIV testing history, risk behaviors, and opinions on the FTP. Those who had previously been tested preferred traditional methods to video counseling. MSM and truck drivers equally preferred video counseling, although MSM who had been previously tested preferred traditional methods. Nearly all participants preferred oral testing. Rates of counseling completion and linkage to government centers were low, with one third of newly identified positives completing follow-up. With increased public-private coordination, this FTP could identify many hard-to-reach preliminary positive individuals and connect them to government testing and care. PMID:22827901

  6. Verification of BOUT++ by the method of manufactured solutions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dudson, B. D., E-mail: benjamin.dudson@york.ac.uk; Hill, P.; Madsen, J.

    2016-06-15

    BOUT++ is a software package designed for solving plasma fluid models. It has been used to simulate a wide range of plasma phenomena ranging from linear stability analysis to 3D plasma turbulence and is capable of simulating a wide range of drift-reduced plasma fluid and gyro-fluid models. A verification exercise has been performed as part of a EUROfusion Enabling Research project, to rigorously test the correctness of the algorithms implemented in BOUT++, by testing order-of-accuracy convergence rates using the Method of Manufactured Solutions (MMS). We present tests of individual components including time-integration and advection schemes, non-orthogonal toroidal field-aligned coordinate systemsmore » and the shifted metric procedure which is used to handle highly sheared grids. The flux coordinate independent approach to differencing along magnetic field-lines has been implemented in BOUT++ and is here verified using the MMS in a sheared slab configuration. Finally, we show tests of three complete models: 2-field Hasegawa-Wakatani in 2D slab, 3-field reduced magnetohydrodynamics (MHD) in 3D field-aligned toroidal coordinates, and 5-field reduced MHD in slab geometry.« less

  7. Development of a high sensitivity pinhole type gamma camera using semiconductors for low dose rate fields

    NASA Astrophysics Data System (ADS)

    Ueno, Yuichiro; Takahashi, Isao; Ishitsu, Takafumi; Tadokoro, Takahiro; Okada, Koichi; Nagumo, Yasushi; Fujishima, Yasutake; Yoshida, Akira; Umegaki, Kikuo

    2018-06-01

    We developed a pinhole type gamma camera, using a compact detector module of a pixelated CdTe semiconductor, which has suitable sensitivity and quantitative accuracy for low dose rate fields. In order to improve the sensitivity of the pinhole type semiconductor gamma camera, we adopted three methods: a signal processing method to set the discriminating level lower, a high sensitivity pinhole collimator and a smoothing image filter that improves the efficiency of the source identification. We tested basic performances of the developed gamma camera and carefully examined effects of the three methods. From the sensitivity test, we found that the effective sensitivity was about 21 times higher than that of the gamma camera for high dose rate fields which we had previously developed. We confirmed that the gamma camera had sufficient sensitivity and high quantitative accuracy; for example, a weak hot spot (0.9 μSv/h) around a tree root could be detected within 45 min in a low dose rate field test, and errors of measured dose rates with point sources were less than 7% in a dose rate accuracy test.

  8. Efficacy of a lead based paint XRF analyzer and a commercially available colorimetric lead test kit as qualitative field tools for determining presence of lead in religious powders.

    PubMed

    Shah, Manthan P; Shendell, Derek G; Meng, Qingyu; Ohman-Strickland, Pamela; Halperin, William

    2018-04-23

    The performances of a portable X-Ray Fluorescence (XRF) lead paint analyzer (RMD LPA-1, Protec Instrument Corp., Waltham, MA) and a commercially available colorimetric lead test kit (First Alert Lead Test Kit, eAccess Solutions, Inc., Palatine, IL) were evaluated for use by local or state health departments as potential cost-effective rapid analysis or "spot test" field techniques for tentative identification of lead content in sindoor powders. For both field-sampling methods, sensitivity, specificity and predictive values varied widely for samples containing <300,000 μg/g lead. For samples containing ≥300,000 μg/g lead, the aforementioned metrics were 100% (however, the CIs had a wide range). In addition, both field sampling methods showed clear, consistent positive readings only for samples containing ≥300,000 μg/g lead. Even samples with lead content as high as 5,110 μg/g were not positively identified by either field analysis technique. The results of this study suggest the XRF analyzer and colorimetric lead test kit cannot be used as a rapid field test for sindoor by health department inspectors.

  9. A field test of point relascope sampling of down coarse woody material in managed stands in the Acadian Forest

    Treesearch

    John C. Brissette; Mark J. Ducey; Jeffrey H. Gove

    2003-01-01

    We field tested a new method for sampling down coarse woody material (CWM) using an angle gauge and compared it with the more traditional line intersect sampling (LIS) method. Permanent sample locations in stands managed with different silvicultural treatments within the Penobscot Experimental Forest (Maine, USA) were used as the sampling locations. Point relascope...

  10. Field test of a new Australian method of rangeland monitoring

    Treesearch

    Suzanne Mayne; Neil West

    2001-01-01

    Managers need more efficient means of monitoring changes on the lands they manage. Accordingly, a new Australian approach was field tested and compared to the Daubenmire method of assessing plant cover, litter, and bare soil. The study area was a 2 mile wide by 30.15 mile long strip, mostly covered by salt desert shrub ecosystem types, centered along the SE boundary of...

  11. Computer tomography of flows external to test models

    NASA Technical Reports Server (NTRS)

    Prikryl, I.; Vest, C. M.

    1982-01-01

    Computer tomographic techniques for reconstruction of three-dimensional aerodynamic density fields, from interferograms recorded from several different viewing directions were studied. Emphasis is on the case in which an opaque object such as a test model in a wind tunnel obscures significant regions of the interferograms (projection data). A method called the Iterative Convolution Method (ICM), existing methods in which the field is represented by a series expansions, and analysis of real experimental data in the form of aerodynamic interferograms are discussed.

  12. Forest Herbicide Washoff From Foliar Applications

    Treesearch

    J.L. Michael; Kevin L. Talley; H.C. Fishburn

    1992-01-01

    Field and laboratory experiments were conducted to develop and test methods for determining washoff of foliar applied herbicides typically used in forestry in the South.Preliminary results show good agreement between results of laboratory methods used and observations from field experiments on actual precipitation events. Methods included application of...

  13. 29 CFR Appendix A to Subpart Q of... - References to subpart Q of Part 1926

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (ASTM C39-86). • Standard Test Method for Making and Curing Concrete Test Specimens in the Field (ASTM C31-85). • Standard Test Method for Penetration Resistance of Hardened Concrete (ASTM C803-82... (ASTM C873-85). • Standard Method for Developing Early Age Compressive Test Values and Projecting Later...

  14. PE Metrics: Background, Testing Theory, and Methods

    ERIC Educational Resources Information Center

    Zhu, Weimo; Rink, Judy; Placek, Judith H.; Graber, Kim C.; Fox, Connie; Fisette, Jennifer L.; Dyson, Ben; Park, Youngsik; Avery, Marybell; Franck, Marian; Raynes, De

    2011-01-01

    New testing theories, concepts, and psychometric methods (e.g., item response theory, test equating, and item bank) developed during the past several decades have many advantages over previous theories and methods. In spite of their introduction to the field, they have not been fully accepted by physical educators. Further, the manner in which…

  15. A simple quality assurance test tool for the visual verification of light and radiation field congruent using electronic portal images device and computed radiography

    PubMed Central

    2012-01-01

    Background The radiation field on most megavoltage radiation therapy units are shown by a light field projected through the collimator by a light source mounted inside the collimator. The light field is traditionally used for patient alignment. Hence it is imperative that the light field is congruent with the radiation field. Method A simple quality assurance tool has been designed for rapid and simple test of the light field and radiation field using electronic portal images device (EPID) or computed radiography (CR). We tested this QA tool using Varian PortalVision and Elekta iViewGT EPID systems and Kodak CR system. Results Both the single and double exposure techniques were evaluated, with double exposure technique providing a better visualization of the light-radiation field markers. The light and radiation congruency could be detected within 1 mm. This will satisfy the American Association of Physicists in Medicine task group report number 142 recommendation of 2 mm tolerance. Conclusion The QA tool can be used with either an EPID or CR to provide a simple and rapid method to verify light and radiation field congruence. PMID:22452821

  16. Automated objective characterization of visual field defects in 3D

    NASA Technical Reports Server (NTRS)

    Fink, Wolfgang (Inventor)

    2006-01-01

    A method and apparatus for electronically performing a visual field test for a patient. A visual field test pattern is displayed to the patient on an electronic display device and the patient's responses to the visual field test pattern are recorded. A visual field representation is generated from the patient's responses. The visual field representation is then used as an input into a variety of automated diagnostic processes. In one process, the visual field representation is used to generate a statistical description of the rapidity of change of a patient's visual field at the boundary of a visual field defect. In another process, the area of a visual field defect is calculated using the visual field representation. In another process, the visual field representation is used to generate a statistical description of the volume of a patient's visual field defect.

  17. Paradigms of Evaluation in Natural Language Processing: Field Linguistics for Glass Box Testing

    ERIC Educational Resources Information Center

    Cohen, Kevin Bretonnel

    2010-01-01

    Although software testing has been well-studied in computer science, it has received little attention in natural language processing. Nonetheless, a fully developed methodology for glass box evaluation and testing of language processing applications already exists in the field methods of descriptive linguistics. This work lays out a number of…

  18. The value of automated gel column agglutination technology in the identification of true inherited D blood types in massively transfused patients.

    PubMed

    Summers, Thomas; Johnson, Viviana V; Stephan, John P; Johnson, Gloria J; Leonard, George

    2009-08-01

    Massive transfusion of D- trauma patients in the combat setting involves the use of D+ red blood cells (RBCs) or whole blood along with suboptimal pretransfusion test result documentation. This presents challenges to the transfusion service of tertiary care military hospitals who ultimately receive these casualties because initial D typing results may only reflect the transfused RBCs. After patients are stabilized, mixed-field reaction results on D typing indicate the patient's true inherited D phenotype. This case series illustrates the utility of automated gel column agglutination in detecting mixed-field reactions in these patients. The transfusion service test results, including the automated gel column agglutination D typing results, of four massively transfused D- patients transfused D+ RBCs is presented. To test the sensitivity of the automated gel column agglutination method in detecting mixed-field agglutination reactions, a comparative analysis of three automated technologies using predetermined mixtures of D+ and D- RBCs is also presented. The automated gel column agglutination method detected mixed-field agglutination in D typing in all four patients and in the three prepared control specimens. The automated microwell tube method identified one of the three prepared control specimens as indeterminate, which was subsequently manually confirmed as a mixed-field reaction. The automated solid-phase method was unable to detect any mixed fields. The automated gel column agglutination method provides a sensitive means for detecting mixed-field agglutination reactions in the determination of the true inherited D phenotype of combat casualties transfused massive amounts of D+ RBCs.

  19. Field trip method as an effort to reveal student environmental literacy on biodiversity issue and context

    NASA Astrophysics Data System (ADS)

    Rijal, M.; Saefudin; Amprasto

    2018-05-01

    Field trip method through investigation of local biodiversity cases can give educational experiences for students. This learning activity was efforts to reveal students environmental literacy on biodiversity. The aim of study were (1) to describe the activities of students get information about the biodiversity issue and its context through field trip, (2) to describe the students findings during field trip, and (3) to reveal students environmental literacy based on pre test and post test. The research method used weak-experiment and involved 34 participants at senior high school students in Bandung-Indonesia. The research instruments for collecting data were environmental literacy test, observation sheets and questionnaire sheets for students. The analysis of data was quantitative descriptive. The results show that more than 79% of the students gave positive view for each field trip activity, i.e students activity during work (97%-100%); students activity during gather information (79%- 100%); students activity during exchange information with friend (82%-100%); and students interested to Biodiversity after field trip activity (85%-100%). Students gain knowledge about the diversity of animal vertebrate and its characteristics, the status and condition of animals, and the source of animal with the cases of animal diversity. The students environmental literacy tends to be moderate level based on test. Meanwhile, the average of the attitudes and action greater than the components of knowledge and cognitive skills.

  20. Three-Dimensional Bayesian Geostatistical Aquifer Characterization at the Hanford 300 Area using Tracer Test Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Xingyuan; Murakami, Haruko; Hahn, Melanie S.

    2012-06-01

    Tracer testing under natural or forced gradient flow holds the potential to provide useful information for characterizing subsurface properties, through monitoring, modeling and interpretation of the tracer plume migration in an aquifer. Non-reactive tracer experiments were conducted at the Hanford 300 Area, along with constant-rate injection tests and electromagnetic borehole flowmeter (EBF) profiling. A Bayesian data assimilation technique, the method of anchored distributions (MAD) [Rubin et al., 2010], was applied to assimilate the experimental tracer test data with the other types of data and to infer the three-dimensional heterogeneous structure of the hydraulic conductivity in the saturated zone of themore » Hanford formation. In this study, the Bayesian prior information on the underlying random hydraulic conductivity field was obtained from previous field characterization efforts using the constant-rate injection tests and the EBF data. The posterior distribution of the conductivity field was obtained by further conditioning the field on the temporal moments of tracer breakthrough curves at various observation wells. MAD was implemented with the massively-parallel three-dimensional flow and transport code PFLOTRAN to cope with the highly transient flow boundary conditions at the site and to meet the computational demands of MAD. A synthetic study proved that the proposed method could effectively invert tracer test data to capture the essential spatial heterogeneity of the three-dimensional hydraulic conductivity field. Application of MAD to actual field data shows that the hydrogeological model, when conditioned on the tracer test data, can reproduce the tracer transport behavior better than the field characterized without the tracer test data. This study successfully demonstrates that MAD can sequentially assimilate multi-scale multi-type field data through a consistent Bayesian framework.« less

  1. Assessment of soil compaction properties based on surface wave techniques

    NASA Astrophysics Data System (ADS)

    Jihan Syamimi Jafri, Nur; Rahim, Mohd Asri Ab; Zahid, Mohd Zulham Affandi Mohd; Faizah Bawadi, Nor; Munsif Ahmad, Muhammad; Faizal Mansor, Ahmad; Omar, Wan Mohd Sabki Wan

    2018-03-01

    Soil compaction plays an important role in every construction activities to reduce risks of any damage. Traditionally, methods of assessing compaction include field tests and invasive penetration tests for compacted areas have great limitations, which caused time-consuming in evaluating large areas. Thus, this study proposed the possibility of using non-invasive surface wave method like Multi-channel Analysis of Surface Wave (MASW) as a useful tool for assessing soil compaction. The aim of this study was to determine the shear wave velocity profiles and field density of compacted soils under varying compaction efforts by using MASW method. Pre and post compaction of MASW survey were conducted at Pauh Campus, UniMAP after applying rolling compaction with variation of passes (2, 6 and 10). Each seismic data was recorded by GEODE seismograph. Sand replacement test was conducted for each survey line to obtain the field density data. All seismic data were processed using SeisImager/SW software. The results show the shear wave velocity profiles increase with the number of passes from 0 to 6 passes, but decrease after 10 passes. This method could attract the interest of geotechnical community, as it can be an alternative tool to the standard test for assessing of soil compaction in the field operation.

  2. Performance evaluation of infrared imaging system in field test

    NASA Astrophysics Data System (ADS)

    Wang, Chensheng; Guo, Xiaodong; Ren, Tingting; Zhang, Zhi-jie

    2014-11-01

    Infrared imaging system has been applied widely in both military and civilian fields. Since the infrared imager has various types and different parameters, for system manufacturers and customers, there is great demand for evaluating the performance of IR imaging systems with a standard tool or platform. Since the first generation IR imager was developed, the standard method to assess the performance has been the MRTD or related improved methods which are not perfect adaptable for current linear scanning imager or 2D staring imager based on FPA detector. For this problem, this paper describes an evaluation method based on the triangular orientation discrimination metric which is considered as the effective and emerging method to evaluate the synthesis performance of EO system. To realize the evaluation in field test, an experiment instrument is developed. And considering the importance of operational environment, the field test is carried in practical atmospheric environment. The test imagers include panoramic imaging system and staring imaging systems with different optics and detectors parameters (both cooled and uncooled). After showing the instrument and experiment setup, the experiment results are shown. The target range performance is analyzed and discussed. In data analysis part, the article gives the range prediction values obtained from TOD method, MRTD method and practical experiment, and shows the analysis and results discussion. The experimental results prove the effectiveness of this evaluation tool, and it can be taken as a platform to give the uniform performance prediction reference.

  3. Alternative methods of flexible base compaction acceptance.

    DOT National Transportation Integrated Search

    2012-05-01

    In the Texas Department of Transportation, flexible base construction is governed by a series of stockpile : and field tests. A series of concerns with these existing methods, along with some premature failures in the : field, led to this project inv...

  4. Measuring the orthogonality error of coil systems

    USGS Publications Warehouse

    Heilig, B.; Csontos, A.; Pajunpää, K.; White, Tim; St. Louis, B.; Calp, D.

    2012-01-01

    Recently, a simple method was proposed for the determination of pitch angle between two coil axes by means of a total field magnetometer. The method is applicable when the homogeneous volume in the centre of the coil system is large enough to accommodate the total field sensor. Orthogonality of calibration coil systems used for calibrating vector magnetometers can be attained by this procedure. In addition, the method can be easily automated and applied to the calibration of delta inclination–delta declination (dIdD) magnetometers. The method was tested by several independent research groups, having a variety of test equipment, and located at differing geomagnetic observatories, including: Nurmijärvi, Finland; Hermanus, South Africa; Ottawa, Canada; Tihany, Hungary. This paper summarizes the test results, and discusses the advantages and limitations of the method.

  5. On the design of innovative heterogeneous tests using a shape optimization approach

    NASA Astrophysics Data System (ADS)

    Aquino, J.; Campos, A. Andrade; Souto, N.; Thuillier, S.

    2018-05-01

    The development of full-field measurement methods enabled a new trend of mechanical tests. By providing the inhomogeneous strain field from the tests, these techniques are being widely used in sheet metal identification strategies, through heterogeneous mechanical tests. In this work, a heterogeneous mechanical test with an innovative tool/specimen shape, capable of producing rich heterogeneous strain paths providing extensive information on material behavior, is aimed. The specimen is found using a shape optimization process where a dedicated indicator that evaluates the richness of strain information is used. The methodology and results here presented are extended to non-specimen geometry dependence and to the non-dependence of the geometry parametrization through the use of the Ritz method for boundary value problems. Different curve models, such as Splines, B-Splines and NURBS, are used and C1 continuity throughout the specimen is guaranteed. Moreover, various optimization methods are used, deterministic and stochastic, in order to find the method or a combination of methods able to effectively minimize the cost function.

  6. Improving the quality of parameter estimates obtained from slug tests

    USGS Publications Warehouse

    Butler, J.J.; McElwee, C.D.; Liu, W.

    1996-01-01

    The slug test is one of the most commonly used field methods for obtaining in situ estimates of hydraulic conductivity. Despite its prevalence, this method has received criticism from many quarters in the ground-water community. This criticism emphasizes the poor quality of the estimated parameters, a condition that is primarily a product of the somewhat casual approach that is often employed in slug tests. Recently, the Kansas Geological Survey (KGS) has pursued research directed it improving methods for the performance and analysis of slug tests. Based on extensive theoretical and field research, a series of guidelines have been proposed that should enable the quality of parameter estimates to be improved. The most significant of these guidelines are: (1) three or more slug tests should be performed at each well during a given test period; (2) two or more different initial displacements (Ho) should be used at each well during a test period; (3) the method used to initiate a test should enable the slug to be introduced in a near-instantaneous manner and should allow a good estimate of Ho to be obtained; (4) data-acquisition equipment that enables a large quantity of high quality data to be collected should be employed; (5) if an estimate of the storage parameter is needed, an observation well other than the test well should be employed; (6) the method chosen for analysis of the slug-test data should be appropriate for site conditions; (7) use of pre- and post-analysis plots should be an integral component of the analysis procedure, and (8) appropriate well construction parameters should be employed. Data from slug tests performed at a number of KGS field sites demonstrate the importance of these guidelines.

  7. Experimental field test of proposed pedestrian safety messages. Volume 1, Methods and materials development

    DOT National Transportation Integrated Search

    1983-11-01

    Author's abstract: A detailed re-analysis of available pedestrian accident data was utilized to define three sets of pedestrian safety public information and education (PI&E) messages. These messages were then produced and field tested. The objective...

  8. 40 CFR 53.58 - Operational field precision and blank test.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PROGRAMS (CONTINUED) AMBIENT AIR MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II Equivalent... samplers are also subject to a test for possible deposition of particulate matter on inactive filters...

  9. 40 CFR 53.58 - Operational field precision and blank test.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PROGRAMS (CONTINUED) AMBIENT AIR MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II Equivalent... samplers are also subject to a test for possible deposition of particulate matter on inactive filters...

  10. 40 CFR 53.58 - Operational field precision and blank test.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... PROGRAMS (CONTINUED) AMBIENT AIR MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II Equivalent... samplers are also subject to a test for possible deposition of particulate matter on inactive filters...

  11. 40 CFR 53.58 - Operational field precision and blank test.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... PROGRAMS (CONTINUED) AMBIENT AIR MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II Equivalent... samplers are also subject to a test for possible deposition of particulate matter on inactive filters...

  12. Open-Source Photometric System for Enzymatic Nitrate Quantification

    PubMed Central

    Wittbrodt, B. T.; Squires, D. A.; Walbeck, J.; Campbell, E.; Campbell, W. H.; Pearce, J. M.

    2015-01-01

    Nitrate, the most oxidized form of nitrogen, is regulated to protect people and animals from harmful levels as there is a large over abundance due to anthropogenic factors. Widespread field testing for nitrate could begin to address the nitrate pollution problem, however, the Cadmium Reduction Method, the leading certified method to detect and quantify nitrate, demands the use of a toxic heavy metal. An alternative, the recently proposed Environmental Protection Agency Nitrate Reductase Nitrate-Nitrogen Analysis Method, eliminates this problem but requires an expensive proprietary spectrophotometer. The development of an inexpensive portable, handheld photometer will greatly expedite field nitrate analysis to combat pollution. To accomplish this goal, a methodology for the design, development, and technical validation of an improved open-source water testing platform capable of performing Nitrate Reductase Nitrate-Nitrogen Analysis Method. This approach is evaluated for its potential to i) eliminate the need for toxic chemicals in water testing for nitrate and nitrite, ii) reduce the cost of equipment to perform this method for measurement for water quality, and iii) make the method easier to carryout in the field. The device is able to perform as well as commercial proprietary systems for less than 15% of the cost for materials. This allows for greater access to the technology and the new, safer nitrate testing technique. PMID:26244342

  13. Open-Source Photometric System for Enzymatic Nitrate Quantification.

    PubMed

    Wittbrodt, B T; Squires, D A; Walbeck, J; Campbell, E; Campbell, W H; Pearce, J M

    2015-01-01

    Nitrate, the most oxidized form of nitrogen, is regulated to protect people and animals from harmful levels as there is a large over abundance due to anthropogenic factors. Widespread field testing for nitrate could begin to address the nitrate pollution problem, however, the Cadmium Reduction Method, the leading certified method to detect and quantify nitrate, demands the use of a toxic heavy metal. An alternative, the recently proposed Environmental Protection Agency Nitrate Reductase Nitrate-Nitrogen Analysis Method, eliminates this problem but requires an expensive proprietary spectrophotometer. The development of an inexpensive portable, handheld photometer will greatly expedite field nitrate analysis to combat pollution. To accomplish this goal, a methodology for the design, development, and technical validation of an improved open-source water testing platform capable of performing Nitrate Reductase Nitrate-Nitrogen Analysis Method. This approach is evaluated for its potential to i) eliminate the need for toxic chemicals in water testing for nitrate and nitrite, ii) reduce the cost of equipment to perform this method for measurement for water quality, and iii) make the method easier to carryout in the field. The device is able to perform as well as commercial proprietary systems for less than 15% of the cost for materials. This allows for greater access to the technology and the new, safer nitrate testing technique.

  14. Estimation of seismic quality factor: Artificial neural networks and current approaches

    NASA Astrophysics Data System (ADS)

    Yıldırım, Eray; Saatçılar, Ruhi; Ergintav, Semih

    2017-01-01

    The aims of this study are to estimate soil attenuation using alternatives to traditional methods, to compare results of using these methods, and to examine soil properties using the estimated results. The performances of all methods, amplitude decay, spectral ratio, Wiener filter, and artificial neural network (ANN) methods, are examined on field and synthetic data with noise and without noise. High-resolution seismic reflection field data from Yeniköy (Arnavutköy, İstanbul) was used as field data, and 424 estimations of Q values were made for each method (1,696 total). While statistical tests on synthetic and field data are quite close to the Q value estimation results of ANN, Wiener filter, and spectral ratio methods, the amplitude decay methods showed a higher estimation error. According to previous geological and geophysical studies in this area, the soil is water-saturated, quite weak, consisting of clay and sandy units, and, because of current and past landslides in the study area and its vicinity, researchers reported heterogeneity in the soil. Under the same physical conditions, Q value calculated on field data can be expected to be 7.9 and 13.6. ANN models with various structures, training algorithm, input, and number of neurons are investigated. A total of 480 ANN models were generated consisting of 60 models for noise-free synthetic data, 360 models for different noise content synthetic data and 60 models to apply to the data collected in the field. The models were tested to determine the most appropriate structure and training algorithm. In the final ANN, the input vectors consisted of the difference of the width, energy, and distance of seismic traces, and the output was Q value. Success rate of both ANN methods with noise-free and noisy synthetic data were higher than the other three methods. Also according to the statistical tests on estimated Q value from field data, the method showed results that are more suitable. The Q value can be estimated practically and quickly by processing the traces with the recommended ANN model. Consequently, the ANN method could be used for estimating Q value from seismic data.

  15. Ion and impurity transport in turbulent, anisotropic magnetic fields

    NASA Astrophysics Data System (ADS)

    Negrea, M.; Petrisor, I.; Isliker, H.; Vogiannou, A.; Vlahos, L.; Weyssow, B.

    2011-08-01

    We investigate ion and impurity transport in turbulent, possibly anisotropic, magnetic fields. The turbulent magnetic field is modeled as a correlated stochastic field, with Gaussian distribution function and prescribed spatial auto-correlation function, superimposed onto a strong background field. The (running) diffusion coefficients of ions are determined in the three-dimensional environment, using two alternative methods, the semi-analytical decorrelation trajectory (DCT) method, and test-particle simulations. In a first step, the results of the test-particle simulations are compared with and used to validate the results obtained from the DCT method. For this purpose, a drift approximation was made in slab geometry, and relatively good qualitative agreement between the DCT method and the test-particle simulations was found. In a second step, the ion species He, Be, Ne and W, all assumed to be fully ionized, are considered under ITER-like conditions, and the scaling of their diffusivities is determined with respect to varying levels of turbulence (varying Kubo number), varying degrees of anisotropy of the turbulent structures and atomic number. In a third step, the test-particle simulations are repeated without drift approximation, directly using the Lorentz force, first in slab geometry, in order to assess the finite Larmor radius effects, and second in toroidal geometry, to account for the geometric effects. It is found that both effects are important, most prominently the effects due to toroidal geometry and the diffusivities are overestimated in slab geometry by an order of magnitude.

  16. PV systems photoelectric parameters determining for field conditions and real operation conditions

    NASA Astrophysics Data System (ADS)

    Shepovalova, Olga V.

    2018-05-01

    In this work, research experience and reference documentation have been generalized related to PV systems photoelectric parameters (PV array output parameters) determining. The basic method has been presented that makes it possible to determine photoelectric parameters with the state-of-the-art reliability and repeatability. This method provides an effective tool for PV systems comparison and evaluation of PV system parameters that the end-user will have in the course of its real operation for compliance with those stipulated in reference documentation. The method takes in consideration all parameters that may possibly affect photoelectric performance and that are supported by sufficiently valid procedures for their values testing. Test conditions, requirements for equipment subject to tests and test preparations have been established and the test procedure for fully equipped PV system in field tests and in real operation conditions has been described.

  17. Multi-level slug tests in highly permeable formations: 2. Hydraulic conductivity identification, method verification, and field applications

    USGS Publications Warehouse

    Zlotnik, V.A.; McGuire, V.L.

    1998-01-01

    Using the developed theory and modified Springer-Gelhar (SG) model, an identification method is proposed for estimating hydraulic conductivity from multi-level slug tests. The computerized algorithm calculates hydraulic conductivity from both monotonic and oscillatory well responses obtained using a double-packer system. Field verification of the method was performed at a specially designed fully penetrating well of 0.1-m diameter with a 10-m screen in a sand and gravel alluvial aquifer (MSEA site, Shelton, Nebraska). During well installation, disturbed core samples were collected every 0.6 m using a split-spoon sampler. Vertical profiles of hydraulic conductivity were produced on the basis of grain-size analysis of the disturbed core samples. These results closely correlate with the vertical profile of horizontal hydraulic conductivity obtained by interpreting multi-level slug test responses using the modified SG model. The identification method was applied to interpret the response from 474 slug tests in 156 locations at the MSEA site. More than 60% of responses were oscillatory. The method produced a good match to experimental data for both oscillatory and monotonic responses using an automated curve matching procedure. The proposed method allowed us to drastically increase the efficiency of each well used for aquifer characterization and to process massive arrays of field data. Recommendations generalizing this experience to massive application of the proposed method are developed.Using the developed theory and modified Springer-Gelhar (SG) model, an identification method is proposed for estimating hydraulic conductivity from multi-level slug tests. The computerized algorithm calculates hydraulic conductivity from both monotonic and oscillatory well responses obtained using a double-packer system. Field verification of the method was performed at a specially designed fully penetrating well of 0.1-m diameter with a 10-m screen in a sand and gravel alluvial aquifer (MSEA site, Shelton, Nebraska). During well installation, disturbed core samples were collected every 0.6 m using a split-spoon sampler. Vertical profiles of hydraulic conductivity were produced on the basis of grain-size analysis of the disturbed core samples. These results closely correlate with the vertical profile of horizontal hydraulic conductivity obtained by interpreting multi-level slug test responses using the modified SG model. The identification method was applied to interpret the response from 474 slug tests in 156 locations at the MSEA site. More than 60% of responses were oscillatory. The method produced a good match to experimental data for both oscillatory and monotonic responses using an automated curve matching procedure. The proposed method allowed us to drastically increase the efficiency of each well used for aquifer characterization and to process massive arrays of field data. Recommendations generalizing this experience to massive application of the proposed method are developed.

  18. Applications of aerospace technology in industry: A technology transfer profile, nondestructive testing

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The development of nondestructive testing procedures by NASA and the transfer of nondestructive testing to technology to civilian industry are discussed. The subjects presented are: (1) an overview of the nondestructive testing field, (2) NASA contributions to the field of nondestructive testing, (3) dissemination of NASA contributions, and (4) a transfer profile. Attachments are included which provide a brief description of common nondestructive testing methods and summarize the technology transfer reports involving NASA generated nondestructive testing technology.

  19. High current superconductors for tokamak toroidal field coils

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fietz, W.A.

    1976-01-01

    Conductors rated at 10,000 A for 8 T and 4.2 K are being purchased for the first large coil segment tests at ORNL. Requirements for these conductors, in addition to the high current rating, are low pulse losses, cryostatic stability, and acceptable mechanical properties. The conductors are required to have losses less than 0.4 W/m under pulsed fields of 0.5 T with a rise time of 1 sec in an ambient 8-T field. Methods of calculating these losses and techniques for verifying the performance by direct measurement are discussed. Conductors stabilized by two different cooling methods, pool boiling and forcedmore » helium flow, have been proposed. Analysis of these conductors is presented and a proposed definition and test of stability is discussed. Mechanical property requirements, tensile and compressive, are defined and test methods are discussed.« less

  20. Development of wheelchair caster testing equipment and preliminary testing of caster models

    PubMed Central

    Mhatre, Anand; Ott, Joseph

    2017-01-01

    Background Because of the adverse environmental conditions present in less-resourced environments (LREs), the World Health Organization (WHO) has recommended that specialised wheelchair test methods may need to be developed to support product quality standards in these environments. A group of experts identified caster test methods as a high priority because of their common failure in LREs, and the insufficiency of existing test methods described in the International Organization for Standardization (ISO) Wheelchair Testing Standards (ISO 7176). Objectives To develop and demonstrate the feasibility of a caster system test method. Method Background literature and expert opinions were collected to identify existing caster test methods, caster failures common in LREs and environmental conditions present in LREs. Several conceptual designs for the caster testing method were developed, and through an iterative process using expert feedback, a final concept and a design were developed and a prototype was fabricated. Feasibility tests were conducted by testing a series of caster systems from wheelchairs used in LREs, and failure modes were recorded and compared to anecdotal reports about field failures. Results The new caster testing system was developed and it provides the flexibility to expose caster systems to typical conditions in LREs. Caster failures such as stem bolt fractures, fork fractures, bearing failures and tire cracking occurred during testing trials and are consistent with field failures. Conclusion The new caster test system has the capability to incorporate necessary test factors that degrade caster quality in LREs. Future work includes developing and validating a testing protocol that results in failure modes common during wheelchair use in LRE. PMID:29062762

  1. Determination of hydraulic conductivity in three dimensions and its relation to dispersivity: Chapter D in Ground-water contamination by crude oil at the Bemidji, Minnesota, research site; US Geological Survey Toxic Waste--ground-water contamination study

    USGS Publications Warehouse

    1984-01-01

    Recent investigations suggest that dispersion in aquifers is scale dependent and a function of the heterogeneity of aquifer materials. Theoretical stochastic studies indicate that determining hydraulic-conductivity variability in three dimensions is important in analyzing the dispersion process. Even though field methods are available to approximate hydraulic conductivity in three dimensions, the methods are not generally used because of high cost of field equipment and because measurement and analysis techniques are cumbersome and time consuming. The hypothesis of this study is that field-determined values of dispersivity are scale dependent and that they may be described as a function of hydraulic conductivity in three dimensions. The objectives of the study at the Bemidji research site are to (1) determine hydraulic conductivity of the porous media in three dimensions, (2) determine field values of dispersivity and its scale dependence on hydraulic conductivity, and (3) develop and apply a computerized data-collection, storage, and analysis system for field use in comprehensive determination of hydraulic conductivity and dispersivity. Plans for this investigation involve a variety of methods of analysis. Hydraulic conductivity will be determined separately in the horizontal and vertical planes of the hydraulic-conductivity ellipsoid. Field values of dispersivity will be determined by single-well and doublet-well injection or withdrawal tests with tracers. A computerized data-collection, storage, and analysis system to measure pressure, flow rate, tracer concentrations, and temperature will be designed for field testing. Real-time computer programs will be used to analyze field data. The initial methods of analysis will be utilized to meet the objectives of the study. Preliminary field data indicate the aquifer underlying the Bemidji site is vertically heterogeneous, cross-bedded outwash. Preliminary analysis of the flow field around a hypothetical doublet-well tracer test indicates that the location of the wells can affect the field value of dispersivity. Preliminary analysis also indicates that different values of dispersivity may result from anisotropic conditions in tests in which observation wells are located at equal radial distances from either the injection or withdrawal well.

  2. WE-AB-BRB-10: Filmless QA of CyberKnife MLC-Collimated and Iris-Collimated Fields

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gersh, J; Spectrum Medical Physics, LLC, Greenville, SC

    Purpose: Current methods of CK field shape QA is based on the use of radiochromic film. Though accurate results can be attained, these methods are prone to error, time consuming, and expensive. The techniques described herein perform similar QA using the FOIL Detector (Field, Output, and Image Localization). A key feature of this in-house QA solution, and central to this study, is an aSi flat-panel detector which provides the user with the means to perform accurate, immediate, and quantitative field analysis. Methods: The FOIL detector is automatically aligned in the CK beam using fiducial markers implanted within the detector case.more » Once the system is aligned, a treatment plan is delivered which irradiates the flat-panel imager using the field being tested. The current study tests each of the clinically-used fields shaped using the Iris variable-aperture collimation system using a plan which takes 6 minutes to deliver. The user is immediately provided with field diameter and beam profile, as well as a comparison to baseline values. Additionally, the detector is used to acquire and analyze leaf positions of the InCise multi-leaf collimation system. Results: Using a 6-minute plan consisting of 11 beams of 25MU-per-beam, the FOIL detector provided the user with a quantitative analysis of all clinically-used field shapes. The FOIL detector was also able to clearly resolve field edge junctions in a picket fence test, including slight over-travel of individual leaves as well as inter-leaf leakage. Conclusion: The FOIL system provided comparable field diameter and profile data when compared to methods using film; providing results much faster and with 5% of the MU used for film. When used with the MLC system, the FOIL detector provided the means for immediate quantification of the performance of the system through analysis of leaf positions in a picket fence test field. Author is the President/Owner of Spectrum Medical Physics, LLC, a company which maintains contracts with Siemens Healthcare and Standard Imaging, Inc.« less

  3. A Comprehensive Comparison of Relativistic Particle Integrators

    NASA Astrophysics Data System (ADS)

    Ripperda, B.; Bacchini, F.; Teunissen, J.; Xia, C.; Porth, O.; Sironi, L.; Lapenta, G.; Keppens, R.

    2018-03-01

    We compare relativistic particle integrators commonly used in plasma physics, showing several test cases relevant for astrophysics. Three explicit particle pushers are considered, namely, the Boris, Vay, and Higuera–Cary schemes. We also present a new relativistic fully implicit particle integrator that is energy conserving. Furthermore, a method based on the relativistic guiding center approximation is included. The algorithms are described such that they can be readily implemented in magnetohydrodynamics codes or Particle-in-Cell codes. Our comparison focuses on the strengths and key features of the particle integrators. We test the conservation of invariants of motion and the accuracy of particle drift dynamics in highly relativistic, mildly relativistic, and non-relativistic settings. The methods are compared in idealized test cases, i.e., without considering feedback onto the electrodynamic fields, collisions, pair creation, or radiation. The test cases include uniform electric and magnetic fields, {\\boldsymbol{E}}× {\\boldsymbol{B}} fields, force-free fields, and setups relevant for high-energy astrophysics, e.g., a magnetic mirror, a magnetic dipole, and a magnetic null. These tests have direct relevance for particle acceleration in shocks and in magnetic reconnection.

  4. Dark-Adapted Chromatic Perimetry for Measuring Rod Visual Fields in Patients with Retinitis Pigmentosa

    PubMed Central

    Bennett, Lea D.; Klein, Martin; Locke, Kirsten G.; Kiser, Kelly; Birch, David G.

    2017-01-01

    Purpose Although rod photoreceptors are initially affected in retinitis pigmentosa (RP), the full-field of rod vision is not routinely characterized due to the unavailability of commercial devices detecting rod sensitivity. The purpose of this study was to quantify rod-mediated vision in the peripheral field from patients with RP using a new commercially available perimeter. Methods Participants had one eye dilated and dark-adapted for 45 minutes. A dark-adapted chromatic (DAC) perimeter tested 80 loci 144° horizontally and 72° vertically with cyan stimuli. The number of rod-mediated loci (RML) were analyzed based on normal cone sensitivity (method 1) and associated with full-field electroretinography (ERG) responses by Pearson's r correlation and linear regression. In a second cohort of patients with RP, RML were identified by two-color perimetry (cyan and red; method 2). The two methods for ascribing rod function were compared by Bland-Altman analysis. Results Method 1 RML were correlated with responses to the 0.01 cd.s/m2 flash (P < 0.001), while total sensitivity to the cyan stimulus showed correlation with responses to the 3.0 cd.s/m2 flash (P < 0.0001). Method 2 detected a mean of 10 additional RML compared to method 1. Conclusions Scotopic fields measured with the DAC detected rod sensitivity across the full visual field, even in some patients who had nondetectable rod ERGs. Two-color perimetry is warranted when sensitivity to the cyan stimulus is reduced to ≤20 dB to get a true estimation of rod function. Translational Relevance Many genetic forms of retinitis pigmentosa (RP) are caused by mutations in rod-specific genes. However, treatment trials for patients with RP have relied primarily on photopic (cone-mediated) tests as outcome measures because there are a limited number of available testing methods designed to evaluate rod function. Thus, efficient methods for quantifying rod-mediated vision are needed for the rapidly increasing numbers of clinical trials. PMID:28798898

  5. Field and laboratory determination of a poly(vinyl/vinylidene chloride) additive in brick mortar.

    PubMed

    Law, S L; Newman, J H; Ptak, F L

    1990-02-01

    A polymerized vinyl/vinylidene chloride additive, used in brick mortar during the 60s and 70s, is detected at the building site by the field method, which employs a commercially available chloride test strip. The field test results can then be verified by the laboratory methods. In one method, total chlorine in the mortar is determined by an oxygen-bomb method and the additive chloride is determined by difference after water-soluble chlorides have been determined on a separate sample. In the second method, the polymerized additive is extracted directly from the mortar with tetrahydrofuran (THF). The difference in weight before and after extraction of the additive gives the weight of additive in the mortar. Evaporation of the THF from the extract leaves a thin film of the polymer, which gives an infrared "fingerprint" spectrum characteristic of the additive polymer.

  6. Psychophysical assessment of low visual function in patients with retinal degenerative diseases (RDDs) with the Diagnosys full-field stimulus threshold (D-FST).

    PubMed

    Klein, M; Birch, D G

    2009-12-01

    To determine whether the Diagnosys full-field stimulus threshold (D-FST) is a valid, sensitive and repeatable psychophysical method of measuring and following visual function in low-vision subjects. Fifty-three affected eyes of 42 subjects with severe retinal degenerative diseases (RDDs) were tested with achromatic stimuli on the D-FST. Included were subjects who were either unable to perform a static perimetric field or had non-detectable or sub-microvolt electroretinograms (ERGs). A subset of 21 eyes of 17 subjects was tested on both the D-FST and the FST2, a previous established full-field threshold test. Seven eyes of 7 normal control subjects were tested on both the D-FST and the FST2. Results for the two methods were compared with the Bland-Altman test. On the D-FST, a threshold could successfully be determined for 13 of 14 eyes with light perception (LP) only (median 0.9 +/- 1.4 log cd/m2), and all eyes determined to be counting fingers (CF; median 0.3 +/- 1.8 log cd/m2). The median full-field threshold for the normal controls was -4.3 +/- 0.6 log cd/m2 on the D-FST and -4.8 +/- 0.9 log cd/m2 on the FST2. The D-FST offers a commercially available method with a robust psychophysical algorithm and is a useful tool for following visual function in low vision subjects.

  7. Combining 3D Hydraulic Tomography with Tracer Tests for Improved Transport Characterization.

    PubMed

    Sanchez-León, E; Leven, C; Haslauer, C P; Cirpka, O A

    2016-07-01

    Hydraulic tomography (HT) is a method for resolving the spatial distribution of hydraulic parameters to some extent, but many details important for solute transport usually remain unresolved. We present a methodology to improve solute transport predictions by combining data from HT with the breakthrough curve (BTC) of a single forced-gradient tracer test. We estimated the three dimensional (3D) hydraulic-conductivity field in an alluvial aquifer by inverting tomographic pumping tests performed at the Hydrogeological Research Site Lauswiesen close to Tübingen, Germany, using a regularized pilot-point method. We compared the estimated parameter field to available profiles of hydraulic-conductivity variations from direct-push injection logging (DPIL), and validated the hydraulic-conductivity field with hydraulic-head measurements of tests not used in the inversion. After validation, spatially uniform parameters for dual-domain transport were estimated by fitting tracer data collected during a forced-gradient tracer test. The dual-domain assumption was used to parameterize effects of the unresolved heterogeneity of the aquifer and deemed necessary to fit the shape of the BTC using reasonable parameter values. The estimated hydraulic-conductivity field and transport parameters were subsequently used to successfully predict a second independent tracer test. Our work provides an efficient and practical approach to predict solute transport in heterogeneous aquifers without performing elaborate field tracer tests with a tomographic layout. © 2015, National Ground Water Association.

  8. Comparison of aircraft noise measured in flight test and in the NASA Ames 40- by 80-foot wind tunnel.

    NASA Technical Reports Server (NTRS)

    Atencio, A., Jr.; Soderman, P. T.

    1973-01-01

    A method to determine free-field aircraft noise spectra from wind-tunnel measurements has been developed. The crux of the method is the correction for reverberations. Calibrated loud speakers are used to simulate model sound sources in the wind tunnel. Corrections based on the difference between the direct and reverberant field levels are applied to wind-tunnel data for a wide range of aircraft noise sources. To establish the validity of the correction method, two research aircraft - one propeller-driven (YOV-10A) and one turbojet-powered (XV-5B) - were flown in free field and then tested in the wind tunnel. Corrected noise spectra from the two environments agree closely.

  9. 40 CFR 60.52Da - Recordkeeping requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Electric Utility... opacity field data sheets; (2) For each performance test conducted using Method 22 of appendix A-4 of this... performance test; (iii) Copies of all visible emission observer opacity field data sheets; and (iv...

  10. Field test method to determine presence and quantity of modifiers in liquid asphalt.

    DOT National Transportation Integrated Search

    2015-05-01

    Asphalt modified with styrene butadiene styrene (SBS) polymer and/or ground tire rubber (GTR) is widely used in the U.S. : to enhance its performance. However, there are very few field tests developed to verify the content of modifier(s) in asphalt :...

  11. Using slides to test for changes in crown defoliation assessment methods. Part I: Visual assessment of slides.

    PubMed

    Dobbertin, Matthias; Hug, Christian; Mizoue, Nobuya

    2004-11-01

    In this study we used photographs of tree crowns to test whether the assessment methods for tree defoliation in Switzerland have changed over time. We randomly selected 24 series of slides of Norway spruce with field assessments made between 1986 and 1995. The slides were randomly arranged and assessed by three experts without prior knowledge of the year when the slide was taken or the tree number. Defoliation was assessed using the Swiss reference photo guide. Although the correlations between the field assessments and slide assessments were high (Spearman's rank correlation coefficient ranged between 0.79 and 0.83), we found significant differences between field and slide assessments (4.3 to 9% underprediction by the slide assessors) and between the slide assessments. However, no significant trends in field assessment methods could be detected. When the mean differences between field and slide assessments were subtracted, in some years, field assessors consistently underpredicted (1990, 1992) or overpredicted defoliation (1987, 1991). Defoliation tended to be overpredicted in slides taken against the light, and underpredicted for trees with more than 25% crown overlap. We conclude that slide series can be used to detect changes in assessment methods. However, potential observer bias calls for more objective methods of assessment.

  12. Toxicity and bioaccumulation of sediment-associated contaminants using freshwater invertebrates: A review of methods and applications

    USGS Publications Warehouse

    Ingersoll, C.G.; Ankley, G.T.; Benoit, D.A.; Brunson, E.L.; Burton, G.A.; Dwyer, F.J.; Hoke, R.A.; Landrum, P.F.; Norberg-King, T. J.; Winger, P.V.

    1995-01-01

    This paper reviews recent developments in methods for evaluating the toxicity and bioaccumulation of contaminants associated with freshwater sediments and summarizes example case studies demonstrating the application of these methods. Over the past decade, research has emphasized development of more specific testing procedures for conducting 10-d toxicity tests with the amphipod Hyalella azteca and the midge Chironomus tentans. Toxicity endpoints measured in these tests are survival for H. azteca and survival and growth for C. tentans. Guidance has also been developed for conducting 28-d bioaccumulation tests with the oligochaete Lumbriculus variegatus, including determination of bioaccumulation kinetics for different compound classes. These methods have been applied to a variety of sediments to address issues ranging from site assessments to bioavailability of organic and inorganic contaminants using field-collected and laboratory-spiked samples. Survival and growth of controls routinely meet or exceed test acceptability criteria. Results of laboratory bioaccumulation studies with L. variegatus have been confirmed with comparisons to residues (PCBs, PAHs, DDT) present from synoptically collected field populations of oligochaetes. Additional method development is currently underway to develop chronic toxicity tests and to provide additional data-confirming responses observed in laboratory sediment tests with natural benthic populations.

  13. [The Diagnostics of Detonation Flow External Field Based on Multispectral Absorption Spectroscopy Technology].

    PubMed

    Lü, Xiao-jing; Li, Ning; Weng, Chun-sheng

    2016-03-01

    Compared with traditional sampling-based sensing method, absorption spectroscopy technology is well suitable for detonation flow diagnostics, since it can provide with us fast response, nonintrusive, sensitive solution for situ measurements of multiple flow-field parameters. The temperature and concentration test results are the average values along the laser path with traditional absorption spectroscopy technology, while the boundary of detonation flow external field is unknown and it changes all the time during the detonation engine works, traditional absorption spectroscopy technology is no longer suitable for detonation diagnostics. The trend of line strength with temperature varies with different absorption lines. By increasing the number of absorption lines in the test path, more information of the non-uniform flow field can be obtained. In this paper, based on multispectral absorption technology, the reconstructed model of detonation flow external field distribution was established according to the simulation results of space-time conservation element and solution element method, and a diagnostic method of detonation flow external field was given. The model deviation and calculation error of the least squares method adopted were studied by simulation, and the maximum concentration and temperature calculation error was 20.1% and 3.2%, respectively. Four absorption lines of H2O were chosen and detonation flow was scanned at the same time. The detonation external flow testing system was set up for the valveless gas-liquid continuous pulse detonation engine with the diameter of 80 mm. Through scanning H2O absorption lines with a high frequency of 10 kHz, the on-line detection of detonation external flow was realized by direct absorption method combined with time-division multiplexing technology, and the reconstruction of dynamic temperature distribution was realized as well for the first time, both verifying the feasibility of the test method. The test results show that both of the temperature and H2O concentration rose with the arrival of detonation wave. With the increase of the vertical distance between the detonation tube nozzle and the laser path, the time of temperature and concentration coming to the peak delayed, and the temperature variation trend tended to slow down. At 20 cm from detonation tube nozzle, the maximum temperature hit 1 329 K and the maximum H2O concentration of 0.19 occurred at 4 ms after ignition. The research can provide with us the support for expanding the detonation test field with absorption spectroscopy technology, and can also help to promote the detonation mechanism research and to enhance the level of detonation engine control technology.

  14. Detection of a sudden change of the field time series based on the Lorenz system.

    PubMed

    Da, ChaoJiu; Li, Fang; Shen, BingLu; Yan, PengCheng; Song, Jian; Ma, DeShan

    2017-01-01

    We conducted an exploratory study of the detection of a sudden change of the field time series based on the numerical solution of the Lorenz system. First, the time when the Lorenz path jumped between the regions on the left and right of the equilibrium point of the Lorenz system was quantitatively marked and the sudden change time of the Lorenz system was obtained. Second, the numerical solution of the Lorenz system was regarded as a vector; thus, this solution could be considered as a vector time series. We transformed the vector time series into a time series using the vector inner product, considering the geometric and topological features of the Lorenz system path. Third, the sudden change of the resulting time series was detected using the sliding t-test method. Comparing the test results with the quantitatively marked time indicated that the method could detect every sudden change of the Lorenz path, thus the method is effective. Finally, we used the method to detect the sudden change of the pressure field time series and temperature field time series, and obtained good results for both series, which indicates that the method can apply to high-dimension vector time series. Mathematically, there is no essential difference between the field time series and vector time series; thus, we provide a new method for the detection of the sudden change of the field time series.

  15. A Lift-Off-Tolerant Magnetic Flux Leakage Testing Method for Drill Pipes at Wellhead.

    PubMed

    Wu, Jianbo; Fang, Hui; Li, Long; Wang, Jie; Huang, Xiaoming; Kang, Yihua; Sun, Yanhua; Tang, Chaoqing

    2017-01-21

    To meet the great needs for MFL (magnetic flux leakage) inspection of drill pipes at wellheads, a lift-off-tolerant MFL testing method is proposed and investigated in this paper. Firstly, a Helmholtz coil magnetization method and the whole MFL testing scheme are proposed. Then, based on the magnetic field focusing effect of ferrite cores, a lift-off-tolerant MFL sensor is developed and tested. It shows high sensitivity at a lift-off distance of 5.0 mm. Further, the follow-up high repeatability MFL probing system is designed and manufactured, which was embedded with the developed sensors. It can track the swing movement of drill pipes and allow the pipe ends to pass smoothly. Finally, the developed system is employed in a drilling field for drill pipe inspection. Test results show that the proposed method can fulfill the requirements for drill pipe inspection at wellheads, which is of great importance in drill pipe safety.

  16. A Lift-Off-Tolerant Magnetic Flux Leakage Testing Method for Drill Pipes at Wellhead

    PubMed Central

    Wu, Jianbo; Fang, Hui; Li, Long; Wang, Jie; Huang, Xiaoming; Kang, Yihua; Sun, Yanhua; Tang, Chaoqing

    2017-01-01

    To meet the great needs for MFL (magnetic flux leakage) inspection of drill pipes at wellheads, a lift-off-tolerant MFL testing method is proposed and investigated in this paper. Firstly, a Helmholtz coil magnetization method and the whole MFL testing scheme are proposed. Then, based on the magnetic field focusing effect of ferrite cores, a lift-off-tolerant MFL sensor is developed and tested. It shows high sensitivity at a lift-off distance of 5.0 mm. Further, the follow-up high repeatability MFL probing system is designed and manufactured, which was embedded with the developed sensors. It can track the swing movement of drill pipes and allow the pipe ends to pass smoothly. Finally, the developed system is employed in a drilling field for drill pipe inspection. Test results show that the proposed method can fulfill the requirements for drill pipe inspection at wellheads, which is of great importance in drill pipe safety. PMID:28117721

  17. Comparison of Field Methods and Models to Estimate Mean Crown Diameter

    Treesearch

    William A. Bechtold; Manfred E. Mielke; Stanley J. Zarnoch

    2002-01-01

    The direct measurement of crown diameters with logger's tapes adds significantly to the cost of extensive forest inventories. We undertook a study of 100 trees to compare this measurement method to four alternatives-two field instruments, ocular estimates, and regression models. Using the taping method as the standard of comparison, accuracy of the tested...

  18. Performance Evaluation of a Salivary Amylase Biosensor for Stress Assessment in Military Field Research.

    PubMed

    Peng, Henry T; Savage, Erin; Vartanian, Oshin; Smith, Shane; Rhind, Shawn G; Tenn, Catherine; Bjamason, Stephen

    2016-05-01

    A convenient biosensor for real-time measurement of biomarkers for in-field psychophysiological stress research and military operations is desirable. We evaluated a hand-held device for measuring salivary amylase as a stress marker in medical technicians undergoing combat casualty care training using two different modalities in operating room and field settings. Salivary amylase activity was measured by two biosensor methods: directly sampling saliva with a test strip placed under the tongue or pipetting a fixed volume of precollected saliva onto the test strip, followed by analyzing the sample on the strip using a biosensor. The two methods were compared for their accuracy and sensitivity to detect the stress response using an enzyme assay method as a standard. The measurements from the under-the-tongue method were not as consistent with those from the standard assay method as the values obtained from the pipetting method. The under-the-tongue method did not detect any significant increase in the amylase activity due to stress in the operating room (P > 0.1), in contrast to the significant increases observed using the pipetting method and assay method with a significance level less than 0.05 and 0.1, respectively. Furthermore, the under-the-tongue method showed no increased amylase activity in the field testing, while both the pipetting method and assay method showed increased amylase activity in the same group (P < 0.1). The accuracy and consistency of the biosensors need to be improved when used to directly measure salivary amylase activity under the tongue for stress assessment in military medical training. © 2015 Her Majesty the Queen in Right of Canada. Journal of Clinical Laboratory Analysis published by Wiley Periodicals, Inc. Reproduced with the permission DRDC Editorial Board.

  19. Termiticides - the Gulfport report

    Treesearch

    Bradford M. Kard

    1999-01-01

    Termiticide treatments to soil are the most widely used and successful method to protect wooden structures from attack by subterranean termites and potentially new termiticides continue to be placed in Forest Service field tests each year. This article presents the latest findings taken from USDA Forest Service field tests in Arizona, Florida, Mississippi, and South...

  20. Application of GPS and Near-Surface Geophysical Methods to Evaluate Agricultural Test Plot Differences

    USDA-ARS?s Scientific Manuscript database

    A field research facility with two pairs of replicated agricultural test plots (four total) was established at a location in northwest Ohio during 2005 for the purpose of studying water table management strategies. Initial efforts at this field research facility were devoted to evaluating difference...

  1. Testing the efficiency of rover science protocols for robotic sample selection: A GeoHeuristic Operational Strategies Test

    NASA Astrophysics Data System (ADS)

    Yingst, R. A.; Bartley, J. K.; Chidsey, T. C.; Cohen, B. A.; Gilleaudeau, G. J.; Hynek, B. M.; Kah, L. C.; Minitti, M. E.; Williams, R. M. E.; Black, S.; Gemperline, J.; Schaufler, R.; Thomas, R. J.

    2018-05-01

    The GHOST field tests are designed to isolate and test science-driven rover operations protocols, to determine best practices. During a recent field test at a potential Mars 2020 landing site analog, we tested two Mars Science Laboratory data-acquisition and decision-making methods to assess resulting science return and sample quality: a linear method, where sites of interest are studied in the order encountered, and a "walkabout-first" method, where sites of interest are examined remotely before down-selecting to a subset of sites that are interrogated with more resource-intensive instruments. The walkabout method cost less time and fewer resources, while increasing confidence in interpretations. Contextual data critical to evaluating site geology was acquired earlier than for the linear method, and given a higher priority, which resulted in development of more mature hypotheses earlier in the analysis process. Combined, this saved time and energy in the collection of data with more limited spatial coverage. Based on these results, we suggest that the walkabout method be used where doing so would provide early context and time for the science team to develop hypotheses-critical tests; and that in gathering context, coverage may be more important than higher resolution.

  2. 9- by 15-Foot Low-Speed Wind Tunnel Acoustic Free Field Evaluation; Part 1: Qualification Report Summary and Part 2: Anechoic Environment Characterization Field Test Report

    NASA Technical Reports Server (NTRS)

    Schmitt, Jeff G.; Stahnke, Brian

    2017-01-01

    This report describes test results from an assessment of the acoustically treated 9x15 Foot Low Speed Wind Tunnel at the NASA Glenn Research Center in Cleveland, Ohio in July of 2016. The tests were conducted in accordance with the recently adopted international standard ISO 26101-2012 on Qualification of Free Field Test Environments. This method involves moving a microphone relative to a source and comparing the sound pressure level versus distance measurements with theoretical inverse square law spreading.

  3. Overview of RICOR's reliability theoretical analysis, accelerated life demonstration test results and verification by field data

    NASA Astrophysics Data System (ADS)

    Vainshtein, Igor; Baruch, Shlomi; Regev, Itai; Segal, Victor; Filis, Avishai; Riabzev, Sergey

    2018-05-01

    The growing demand for EO applications that work around the clock 24hr/7days a week, such as in border surveillance systems, emphasizes the need for a highly reliable cryocooler having increased operational availability and optimized system's Integrated Logistic Support (ILS). In order to meet this need, RICOR developed linear and rotary cryocoolers which achieved successfully this goal. Cryocoolers MTTF was analyzed by theoretical reliability evaluation methods, demonstrated by normal and accelerated life tests at Cryocooler level and finally verified by field data analysis derived from Cryocoolers operating at system level. The following paper reviews theoretical reliability analysis methods together with analyzing reliability test results derived from standard and accelerated life demonstration tests performed at Ricor's advanced reliability laboratory. As a summary for the work process, reliability verification data will be presented as a feedback from fielded systems.

  4. Design and testing of focusing magnets for a compact electron linac

    NASA Astrophysics Data System (ADS)

    Chen, Qushan; Qin, Bin; Liu, Kaifeng; Liu, Xu; Fu, Qiang; Tan, Ping; Hu, Tongning; Pei, Yuanji

    2015-10-01

    Solenoid field errors have great influence on electron beam qualities. In this paper, design and testing of high precision solenoids for a compact electron linac is presented. We proposed an efficient and practical method to solve the peak field of the solenoid for relativistic electron beams based on the reduced envelope equation. Beam dynamics involving space charge force were performed to predict the focusing effects. Detailed optimization methods were introduced to achieve an ultra-compact configuration as well as high accuracy, with the help of the POISSON and OPERA packages. Efforts were attempted to restrain system errors in the off-line testing, which showed the short lens and the main solenoid produced a peak field of 0.13 T and 0.21 T respectively. Data analysis involving central and off axes was carried out and demonstrated that the testing results fitted well with the design.

  5. FIELD OPERATIONS AND METHODS FOR MEASURING THE ECOLOGICAL CONDITION OF WADEABLE STREAMS

    EPA Science Inventory

    The methods and instructions for field operations presented in this manual for surveys of wadeable streams were developed and tested during 5 years of pilot and demonstration projects (1993 through 1997). These projects were conducted under the sponsorship of the U.S. Environment...

  6. Adaptation of the Sensititre broth microdilution technique to antimicrobial susceptibility testing of Mycoplasma hyopneumoniae.

    PubMed

    Tanner, A C; Erickson, B Z; Ross, R F

    1993-09-01

    A broth microdilution technique is described for determining the antimicrobial susceptibility of Mycoplasma hyopneumoniae, using commercially prepared Sensititre plates. Twenty-five field isolates and two reference strains (J & 232), were tested against seven antimicrobials. Field isolates were tested in duplicate and reference strains, four times to estimate reproducibility. Ninety-seven percent of the duplicate MIC results for the field isolates were in agreement, or within one log2 dilution. Similar results were obtained with the reference strains. The isolates were susceptible to lincomycin-spectinomycin, tylosin and oxytetracycline or resistant to amoxycillin, apramycin and erythromycin. Susceptibility to furaltadone varied. This method retains the accuracy and reproducibility of broth MIC determinations, while avoiding the lengthy preparation of antimicrobial dilutions normally associated with more traditional methods.

  7. Accuracy-enhanced constitutive parameter identification using virtual fields method and special stereo-digital image correlation

    NASA Astrophysics Data System (ADS)

    Zhang, Zhongya; Pan, Bing; Grédiac, Michel; Song, Weidong

    2018-04-01

    The virtual fields method (VFM) is generally used with two-dimensional digital image correlation (2D-DIC) or grid method (GM) for identifying constitutive parameters. However, when small out-of-plane translation/rotation occurs to the test specimen, 2D-DIC and GM are prone to yield inaccurate measurements, which further lessen the accuracy of the parameter identification using VFM. In this work, an easy-to-implement but effective "special" stereo-DIC (SS-DIC) method is proposed for accuracy-enhanced VFM identification. The SS-DIC can not only deliver accurate deformation measurement without being affected by unavoidable out-of-plane movement/rotation of a test specimen, but can also ensure evenly distributed calculation data in space, which leads to simple data processing. Based on the accurate kinematics fields with evenly distributed measured points determined by SS-DIC method, constitutive parameters can be identified by VFM with enhanced accuracy. Uniaxial tensile tests of a perforated aluminum plate and pure shear tests of a prismatic aluminum specimen verified the effectiveness and accuracy of the proposed method. Experimental results show that the constitutive parameters identified by VFM using SS-DIC are more accurate and stable than those identified by VFM using 2D-DIC. It is suggested that the proposed SS-DIC can be used as a standard measuring tool for mechanical identification using VFM.

  8. The measurement of heats of solution of high melting metallic systems in an electromagnetic levitation field. Ph.D. Thesis - Tech. Univ. Berlin - 1979

    NASA Technical Reports Server (NTRS)

    Frohberg, M. G.; Betz, G.

    1982-01-01

    A method was tested for measuring the enthalpies of mixing of liquid metallic alloying systems, involving the combination of two samples in the electromagnetic field of an induction coil. The heat of solution is calculated from the pyrometrically measured temperature effect, the heat capacity of the alloy, and the heat content of the added sample. The usefulness of the method was tested experimentally with iron-copper and niobium-silicon systems. This method should be especially applicable to high-melting alloys, for which conventional measurements have failed.

  9. Using Benchmarking To Strengthen the Assessment of Persistence.

    PubMed

    McLachlan, Michael S; Zou, Hongyan; Gouin, Todd

    2017-01-03

    Chemical persistence is a key property for assessing chemical risk and chemical hazard. Current methods for evaluating persistence are based on laboratory tests. The relationship between the laboratory based estimates and persistence in the environment is often unclear, in which case the current methods for evaluating persistence can be questioned. Chemical benchmarking opens new possibilities to measure persistence in the field. In this paper we explore how the benchmarking approach can be applied in both the laboratory and the field to deepen our understanding of chemical persistence in the environment and create a firmer scientific basis for laboratory to field extrapolation of persistence test results.

  10. Three-dimensional Bayesian geostatistical aquifer characterization at the Hanford 300 Area using tracer test data

    NASA Astrophysics Data System (ADS)

    Chen, Xingyuan; Murakami, Haruko; Hahn, Melanie S.; Hammond, Glenn E.; Rockhold, Mark L.; Zachara, John M.; Rubin, Yoram

    2012-06-01

    Tracer tests performed under natural or forced gradient flow conditions can provide useful information for characterizing subsurface properties, through monitoring, modeling, and interpretation of the tracer plume migration in an aquifer. Nonreactive tracer experiments were conducted at the Hanford 300 Area, along with constant-rate injection tests and electromagnetic borehole flowmeter tests. A Bayesian data assimilation technique, the method of anchored distributions (MAD) (Rubin et al., 2010), was applied to assimilate the experimental tracer test data with the other types of data and to infer the three-dimensional heterogeneous structure of the hydraulic conductivity in the saturated zone of the Hanford formation.In this study, the Bayesian prior information on the underlying random hydraulic conductivity field was obtained from previous field characterization efforts using constant-rate injection and borehole flowmeter test data. The posterior distribution of the conductivity field was obtained by further conditioning the field on the temporal moments of tracer breakthrough curves at various observation wells. MAD was implemented with the massively parallel three-dimensional flow and transport code PFLOTRAN to cope with the highly transient flow boundary conditions at the site and to meet the computational demands of MAD. A synthetic study proved that the proposed method could effectively invert tracer test data to capture the essential spatial heterogeneity of the three-dimensional hydraulic conductivity field. Application of MAD to actual field tracer data at the Hanford 300 Area demonstrates that inverting for spatial heterogeneity of hydraulic conductivity under transient flow conditions is challenging and more work is needed.

  11. Examination of a Model for Field Studies in Science

    ERIC Educational Resources Information Center

    Riban, David M.

    1976-01-01

    Discusses ways to increase the effectiveness of field studies as an instructional method. Describes a study in which high school students who completed a geological field study scored higher on an earth science test than students who had not participated in the field study. (MLH)

  12. Research of laser stealth performance test technology

    NASA Astrophysics Data System (ADS)

    Chen, Zhen-xing; Shi, Sheng-bing; Han, Fu-li; Wu, Yan-lin; Song, Chun-yan

    2014-09-01

    Laser stealth is an important way of photoelectric stealth weapons systems. According to operational principle of laser range finder, we actively explore and study the stealth performance approval testing technology of laser stealth materials, and bring forward and establish the stealth performance field test methods of stealth efficiency evaluation. Through contrastive test of two kinds of materials, the method is correct and effective.

  13. Research on Horizontal Accuracy Method of High Spatial Resolution Remotely Sensed Orthophoto Image

    NASA Astrophysics Data System (ADS)

    Xu, Y. M.; Zhang, J. X.; Yu, F.; Dong, S.

    2018-04-01

    At present, in the inspection and acceptance of high spatial resolution remotly sensed orthophoto image, the horizontal accuracy detection is testing and evaluating the accuracy of images, which mostly based on a set of testing points with the same accuracy and reliability. However, it is difficult to get a set of testing points with the same accuracy and reliability in the areas where the field measurement is difficult and the reference data with high accuracy is not enough. So it is difficult to test and evaluate the horizontal accuracy of the orthophoto image. The uncertainty of the horizontal accuracy has become a bottleneck for the application of satellite borne high-resolution remote sensing image and the scope of service expansion. Therefore, this paper proposes a new method to test the horizontal accuracy of orthophoto image. This method using the testing points with different accuracy and reliability. These points' source is high accuracy reference data and field measurement. The new method solves the horizontal accuracy detection of the orthophoto image in the difficult areas and provides the basis for providing reliable orthophoto images to the users.

  14. Transonic propulsion system integration analysis at McDonnell Aircraft Company

    NASA Technical Reports Server (NTRS)

    Cosner, Raymond R.

    1989-01-01

    The technology of Computational Fluid Dynamics (CFD) is becoming an important tool in the development of aircraft propulsion systems. Two of the most valuable features of CFD are: (1) quick acquisition of flow field data; and (2) complete description of flow fields, allowing detailed investigation of interactions. Current analysis methods complement wind tunnel testing in several ways. Herein, the discussion is focused on CFD methods. However, aircraft design studies need data from both CFD and wind tunnel testing. Each approach complements the other.

  15. Field test comparison of two dermal tolerance assessment methods of hand hygiene products.

    PubMed

    Girard, R; Carré, E; Pires-Cronenberger, S; Bertin-Mandy, M; Favier-Bulit, M C; Coyault, C; Coudrais, S; Billard, M; Regard, A; Kerhoas, A; Valdeyron, M L; Cracco, B; Misslin, P

    2008-06-01

    This study aimed to compare the sensitivity and workload requirement of two dermal tolerance assessment methods of hand hygiene products, in order to select a suitable pilot testing method for field tests. An observer-rating method and a self-assessment method were compared in 12 voluntary hospital departments (autumn/winter of 2005-2006). Three test-periods of three weeks were separated by two-week intervals during which the routine products were reintroduced. The observer rating method scored dryness and irritation on four-point scales. In the self-assessment method, the user rated appearance, intactness, moisture content, and sensation on a visual analogue scale which was converted into a 10-point numerical scale. Eleven products (soaps) were tested (223/250 complete reports for observer rating, 131/251 for self-assessment). Two products were significantly less well tolerated than the routine product according to the observers, four products according to the self-assessments. There was no significant difference between the two methods when products were classified according to tolerance (Fisher's test: P=0.491). For the symptom common to both assessment methods (dryness), there is a good correlation between the two methods (Spearman's Rho: P=0.032). The workload was higher for observer rating method (288 h of observer time plus 122 h of prevention team and pharmacist time compared with 15 h of prevention team and pharmacist time for self-assessment). In conclusion, the self-assessment method was considered more suitable for pilot testing, although further time should be allocated for educational measures as the return rate of complete self-assessment forms was poor.

  16. Evaluation of ICT filariasis card test using whole capillary blood: comparison with Knott's concentration and counting chamber methods.

    PubMed

    Njenga, S M; Wamae, C N

    2001-10-01

    An immunochromatographic card test (ICT) that uses fingerprick whole blood instead of serum for diagnosis of bancroftian filariasis has recently been developed. The card test was validated in the field in Kenya by comparing its sensitivity to the combined sensitivity of Knott's concentration and counting chamber methods. A total of 102 (14.6%) and 117 (16.7%) persons was found to be microfilaremic by Knott's concentration and counting chamber methods, respectively. The geometric mean intensities (GMI) were 74.6 microfilariae (mf)/ml and 256.5 mf/ml by Knott's concentration and counting chamber methods, respectively. All infected individuals detected by both Knott's concentration and counting chamber methods were also antigen positive by the ICT filariasis card test (100% sensitivity). Further, of 97 parasitologically amicrofilaremic persons, 24 (24.7%) were antigen positive by the ICT. The overall prevalence of antigenemia was 37.3%. Of 100 nonendemic area control persons, none was found to be filarial antigen positive (100% specificity). The results show that the new version of the ICT filariasis card test is a simple, sensitive, specific, and rapid test that is convenient in field settings.

  17. Leap-frog-based BPM (LF-BPM) method for solving nanophotonic structures

    NASA Astrophysics Data System (ADS)

    Ayoub, Ahmad B.; Swillam, Mohamed A.

    2018-02-01

    In this paper, we propose an efficient approach to solve the BPM equation. By splitting the complex field into real and imaginary parts, the method is proved to be at least 30% faster than the conventional BPM. This method was tested on several optical components to test the accuracy.

  18. Wavefront reversal technique for self-referencing collimation testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hii, King Ung; Kwek, Kuan Hiang

    2010-02-01

    We present a wavefront reversal technique to produce a dual-field fringe pattern for self-referencing collimation testing in wedge-plate lateral-shear interferometry. The method requires only a suitably placed cubic beam splitter to produce two replicas of the fringe field formed by the wedge-plate lateral-shear interferometer. One of the replicas has a fringe pattern that is the reverse of the other. With these two fringe fields, the collimation testing has a built-in reference, and the detection sensitivity is twice that of a single-wedge-plate technique.

  19. Application of GPS and Near-Surface Geophysical Methods to Evaluate Differences Between Agricultural Test Plots

    USDA-ARS?s Scientific Manuscript database

    A field research facility with two pairs of replicated agricultural test plots (four total) was established at a location in northwest Ohio during 2005 for the purpose of studying water table management strategies. Initial efforts at this field research facility were devoted to evaluating difference...

  20. An improved design method of a tuned mass damper for an in-service footbridge

    NASA Astrophysics Data System (ADS)

    Shi, Weixing; Wang, Liangkun; Lu, Zheng

    2018-03-01

    Tuned mass damper (TMD) has a wide range of applications in the vibration control of footbridges. However, the traditional engineering design method may lead to a mistuned TMD. In this paper, an improved TMD design method based on the model updating is proposed. Firstly, the original finite element model (FEM) is studied and the natural characteristics of the in-service or newly built footbridge is identified by field test, and then the original FEM is updated. TMD is designed according to the new updated FEM, and it is optimized according to the simulation on vibration control effects. Finally, the installation and field measurement of TMD are carried out. The improved design method can be applied to both in-service and newly built footbridges. This paper illustrates the improved design method with an engineering example. The frequency identification results of field test and original FEM show that there is a relatively large difference between them. The TMD designed according to the updated FEM has better vibration control effect than the TMD designed according to the original FEM. The site test results show that TMD has good effect on controlling human-induced vibrations.

  1. CAFE: A New Relativistic MHD Code

    NASA Astrophysics Data System (ADS)

    Lora-Clavijo, F. D.; Cruz-Osorio, A.; Guzmán, F. S.

    2015-06-01

    We introduce CAFE, a new independent code designed to solve the equations of relativistic ideal magnetohydrodynamics (RMHD) in three dimensions. We present the standard tests for an RMHD code and for the relativistic hydrodynamics regime because we have not reported them before. The tests include the one-dimensional Riemann problems related to blast waves, head-on collisions of streams, and states with transverse velocities, with and without magnetic field, which is aligned or transverse, constant or discontinuous across the initial discontinuity. Among the two-dimensional (2D) and 3D tests without magnetic field, we include the 2D Riemann problem, a one-dimensional shock tube along a diagonal, the high-speed Emery wind tunnel, the Kelvin-Helmholtz (KH) instability, a set of jets, and a 3D spherical blast wave, whereas in the presence of a magnetic field we show the magnetic rotor, the cylindrical explosion, a case of Kelvin-Helmholtz instability, and a 3D magnetic field advection loop. The code uses high-resolution shock-capturing methods, and we present the error analysis for a combination that uses the Harten, Lax, van Leer, and Einfeldt (HLLE) flux formula combined with a linear, piecewise parabolic method and fifth-order weighted essentially nonoscillatory reconstructors. We use the flux-constrained transport and the divergence cleaning methods to control the divergence-free magnetic field constraint.

  2. MICROFLORA INVOLVED IN PHYTOREMEDIATION OF POLYAROMATIC HYDROCARBONS

    EPA Science Inventory

    This research was accomplished by conducting a series of integrated studies starting with field work at contaminated sites, followed by laboratory studies based on the field work, and concluded with development of preliminary molecular monitoring methods tested on field sam...

  3. Evaluation of Hemifield Sector Analysis Protocol in Multifocal Visual Evoked Potential Objective Perimetry for the Diagnosis and Early Detection of Glaucomatous Field Defects

    PubMed Central

    Mousa, Mohammad F.; Cubbidge, Robert P.; Al-Mansouri, Fatima

    2014-01-01

    Purpose Multifocal visual evoked potential (mfVEP) is a newly introduced method used for objective visual field assessment. Several analysis protocols have been tested to identify early visual field losses in glaucoma patients using the mfVEP technique, some were successful in detection of field defects, which were comparable to the standard automated perimetry (SAP) visual field assessment, and others were not very informative and needed more adjustment and research work. In this study we implemented a novel analysis approach and evaluated its validity and whether it could be used effectively for early detection of visual field defects in glaucoma. Methods Three groups were tested in this study; normal controls (38 eyes), glaucoma patients (36 eyes) and glaucoma suspect patients (38 eyes). All subjects had a two standard Humphrey field analyzer (HFA) test 24-2 and a single mfVEP test undertaken in one session. Analysis of the mfVEP results was done using the new analysis protocol; the hemifield sector analysis (HSA) protocol. Analysis of the HFA was done using the standard grading system. Results Analysis of mfVEP results showed that there was a statistically significant difference between the three groups in the mean signal to noise ratio (ANOVA test, p < 0.001 with a 95% confidence interval). The difference between superior and inferior hemispheres in all subjects were statistically significant in the glaucoma patient group in all 11 sectors (t-test, p < 0.001), partially significant in 5 / 11 (t-test, p < 0.01), and no statistical difference in most sectors of the normal group (1 / 11 sectors was significant, t-test, p < 0.9). Sensitivity and specificity of the HSA protocol in detecting glaucoma was 97% and 86%, respectively, and for glaucoma suspect patients the values were 89% and 79%, respectively. Conclusions The new HSA protocol used in the mfVEP testing can be applied to detect glaucomatous visual field defects in both glaucoma and glaucoma suspect patients. Using this protocol can provide information about focal visual field differences across the horizontal midline, which can be utilized to differentiate between glaucoma and normal subjects. Sensitivity and specificity of the mfVEP test showed very promising results and correlated with other anatomical changes in glaucoma field loss. PMID:24511212

  4. Detection of a sudden change of the field time series based on the Lorenz system

    PubMed Central

    Li, Fang; Shen, BingLu; Yan, PengCheng; Song, Jian; Ma, DeShan

    2017-01-01

    We conducted an exploratory study of the detection of a sudden change of the field time series based on the numerical solution of the Lorenz system. First, the time when the Lorenz path jumped between the regions on the left and right of the equilibrium point of the Lorenz system was quantitatively marked and the sudden change time of the Lorenz system was obtained. Second, the numerical solution of the Lorenz system was regarded as a vector; thus, this solution could be considered as a vector time series. We transformed the vector time series into a time series using the vector inner product, considering the geometric and topological features of the Lorenz system path. Third, the sudden change of the resulting time series was detected using the sliding t-test method. Comparing the test results with the quantitatively marked time indicated that the method could detect every sudden change of the Lorenz path, thus the method is effective. Finally, we used the method to detect the sudden change of the pressure field time series and temperature field time series, and obtained good results for both series, which indicates that the method can apply to high-dimension vector time series. Mathematically, there is no essential difference between the field time series and vector time series; thus, we provide a new method for the detection of the sudden change of the field time series. PMID:28141832

  5. Theoretical study on the laser-driven ion-beam trace probe in toroidal devices with large poloidal magnetic field

    NASA Astrophysics Data System (ADS)

    Yang, X.; Xiao, C.; Chen, Y.; Xu, T.; Yu, Y.; Xu, M.; Wang, L.; Wang, X.; Lin, C.

    2018-03-01

    Recently, a new diagnostic method, Laser-driven Ion-beam Trace Probe (LITP), has been proposed to reconstruct 2D profiles of the poloidal magnetic field (Bp) and radial electric field (Er) in the tokamak devices. A linear assumption and test particle model were used in those reconstructions. In some toroidal devices such as the spherical tokamak and the Reversal Field Pinch (RFP), Bp is not small enough to meet the linear assumption. In those cases, the error of reconstruction increases quickly when Bp is larger than 10% of the toroidal magnetic field (Bt), and the previous test particle model may cause large error in the tomography process. Here a nonlinear reconstruction method is proposed for those cases. Preliminary numerical results show that LITP could be applied not only in tokamak devices, but also in other toroidal devices, such as the spherical tokamak, RFP, etc.

  6. Image-optimized Coronal Magnetic Field Models

    NASA Astrophysics Data System (ADS)

    Jones, Shaela I.; Uritsky, Vadim; Davila, Joseph M.

    2017-08-01

    We have reported previously on a new method we are developing for using image-based information to improve global coronal magnetic field models. In that work, we presented early tests of the method, which proved its capability to improve global models based on flawed synoptic magnetograms, given excellent constraints on the field in the model volume. In this follow-up paper, we present the results of similar tests given field constraints of a nature that could realistically be obtained from quality white-light coronagraph images of the lower corona. We pay particular attention to difficulties associated with the line-of-sight projection of features outside of the assumed coronagraph image plane and the effect on the outcome of the optimization of errors in the localization of constraints. We find that substantial improvement in the model field can be achieved with these types of constraints, even when magnetic features in the images are located outside of the image plane.

  7. Image-Optimized Coronal Magnetic Field Models

    NASA Technical Reports Server (NTRS)

    Jones, Shaela I.; Uritsky, Vadim; Davila, Joseph M.

    2017-01-01

    We have reported previously on a new method we are developing for using image-based information to improve global coronal magnetic field models. In that work we presented early tests of the method which proved its capability to improve global models based on flawed synoptic magnetograms, given excellent constraints on the field in the model volume. In this follow-up paper we present the results of similar tests given field constraints of a nature that could realistically be obtained from quality white-light coronagraph images of the lower corona. We pay particular attention to difficulties associated with the line-of-sight projection of features outside of the assumed coronagraph image plane, and the effect on the outcome of the optimization of errors in localization of constraints. We find that substantial improvement in the model field can be achieved with this type of constraints, even when magnetic features in the images are located outside of the image plane.

  8. A Novel Gravity Compensation Method for High Precision Free-INS Based on “Extreme Learning Machine”

    PubMed Central

    Zhou, Xiao; Yang, Gongliu; Cai, Qingzhong; Wang, Jing

    2016-01-01

    In recent years, with the emergency of high precision inertial sensors (accelerometers and gyros), gravity compensation has become a major source influencing the navigation accuracy in inertial navigation systems (INS), especially for high-precision INS. This paper presents preliminary results concerning the effect of gravity disturbance on INS. Meanwhile, this paper proposes a novel gravity compensation method for high-precision INS, which estimates the gravity disturbance on the track using the extreme learning machine (ELM) method based on measured gravity data on the geoid and processes the gravity disturbance to the height where INS has an upward continuation, then compensates the obtained gravity disturbance into the error equations of INS to restrain the INS error propagation. The estimation accuracy of the gravity disturbance data is verified by numerical tests. The root mean square error (RMSE) of the ELM estimation method can be improved by 23% and 44% compared with the bilinear interpolation method in plain and mountain areas, respectively. To further validate the proposed gravity compensation method, field experiments with an experimental vehicle were carried out in two regions. Test 1 was carried out in a plain area and Test 2 in a mountain area. The field experiment results also prove that the proposed gravity compensation method can significantly improve the positioning accuracy. During the 2-h field experiments, the positioning accuracy can be improved by 13% and 29% respectively, in Tests 1 and 2, when the navigation scheme is compensated by the proposed gravity compensation method. PMID:27916856

  9. Compilation of field methods used in geochemical prospecting by the U.S. Geological Survey

    USGS Publications Warehouse

    Lakin, Hubert William; Ward, Frederick Norville; Almond, Hy

    1952-01-01

    The field methods described in this report are those currently used in geochemical prospecting by the U. S. Geological Survey. Some have been published, others are being processed for publication, while others are still being investigated. The purpose in compiling these methods is to make them readily available in convenient form. The methods have not been thoroughly tested and none is wholly satisfactory. Research is being continued.

  10. The students' intentions and satisfaction with the field of study and university

    PubMed Central

    NOORAFSHAN, ALI; POURAHMAD, SAEEDEH; SAGHEB, MOHAMMAD MAHDI; DEHGHANI NAZHVANI, ALI; DEHSHAHRI, ALI; ABDOLLAHI, MANIJEH; MOHEBBI, ZEYNAB; KESHTKARAN, ZAHRA; AHMADI, AFSANEH; KAVOUSIPOUR, SOMAYEH; FARAHMAND, FARIBA; KHORRAMI, HAMID REZA; SOLTANI, ROBABEH; KARBALAY DOUST, SAIED

    2014-01-01

    Introduction: The present study aimed to find an appropriate method to inform senior high school students to correctly select their academic field of study and their intentions. Methods: This is a descriptive-analytic and cross-sectional study. A verified questionnaire was given to a total of 2600 students selected by stratified random sampling method (ten different colleges and entrance year from the 1st to 4th are considered as the strata). The position of the present field of study (major) among the list of the fields in the entrance exam was asked. The students’ methods of familiarity with different fields of study in Shiraz University of Medical Sciences (SUMS), the reasons for their selection, the students’ motivation and insistence on studying in the same field and university were asked in the questionnaire. Data were analyzed using independent two samples t-test, Analysis of Variance (ANOVA) and Chi-Square test. Results: The most significant references for university field selection were high school teachers, the students' parents and the adjacency of university to one's living place. Also, the results revealed the good reputation of SUMS in the first year and its downward trend during the following years. 59.4% of the 1st year students were satisfied with their field of study and SUMS. 31.8% were satisfied with the university but not with their fields of study. 6.4% were dissatisfied with the university but not with their fields of study. 2% of the students were dissatisfied with both their fields of study and university. Dissatisfaction with SUMS and field of study increased little by little so that the results obtained among the students who had entered the university earlier (in the 4th year of their study) showed nearly 16.3% dissatisfaction with both the university and the study fields.   Conclusion: The methods for introducing the university are recommended to be revised. PMID:25512943

  11. Apparatus and procedure to characterize the surface quality of conductors by measuring the rate of cathode emission as a function of surface electric field strength

    DOEpatents

    Mestayer, Mac; Christo, Steve; Taylor, Mark

    2014-10-21

    A device and method for characterizing quality of a conducting surface. The device including a gaseous ionizing chamber having centrally located inside the chamber a conducting sample to be tested to which a negative potential is applied, a plurality of anode or "sense" wires spaced regularly about the central test wire, a plurality of "field wires" at a negative potential are spaced regularly around the sense, and a plurality of "guard wires" at a positive potential are spaced regularly around the field wires in the chamber. The method utilizing the device to measure emission currents from the conductor.

  12. Field Tests of the Magnetotelluric Method to Detect Gas Hydrates, Mallik, Mackenzie Delta, Canada

    NASA Astrophysics Data System (ADS)

    Craven, J. A.; Roberts, B.; Bellefleur, G.; Spratt, J.; Wright, F.; Dallimore, S. R.

    2008-12-01

    The magnetotelluric method is not generally utilized at extreme latitudes due primarily to difficulties in making the good electrical contact with the ground required to measure the electric field. As such, the magnetotelluric technique has not been previously investigated to direct detect gas hydrates in on-shore permafrost environments. We present the results of preliminary field tests at Mallik, Northwest Territories, Canada, that demonstrate good quality magnetotelluric data can be obtained in this environment using specialized electrodes and buffer amplifiers similar to those utilized by Wannamaker et al (2004). This result suggests that subsurface images from larger magnetotelluric surveys will be useful to complement other techniques to detect, quantify and characterize gas hydrates.

  13. FIELD OPERATIONS AND METHODS FOR MEASURING THE ECOLOGICAL CONDITION OF NON-WADEABLE RIVERS AND STREAMS

    EPA Science Inventory

    The methods and instructions for field operations presented in this manual for surveys of non-wadeable streams and rivers were developed and tested based on 55 sample sites in the Mid-Atlantic region and 53 sites in an Oregon study during two years of pilot and demonstration proj...

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Xiao-Dong; Park, Changbom; Forero-Romero, J. E.

    We propose a method based on the redshift dependence of the Alcock-Paczynski (AP) test to measure the expansion history of the universe. It uses the isotropy of the galaxy density gradient field to constrain cosmological parameters. If the density parameter Ω {sub m} or the dark energy equation of state w are incorrectly chosen, the gradient field appears to be anisotropic with the degree of anisotropy varying with redshift. We use this effect to constrain the cosmological parameters governing the expansion history of the universe. Although redshift-space distortions (RSD) induced by galaxy peculiar velocities also produce anisotropies in the gradientmore » field, these effects are close to uniform in magnitude over a large range of redshift. This makes the redshift variation of the gradient field anisotropy relatively insensitive to the RSD. By testing the method on mock surveys drawn from the Horizon Run 3 cosmological N-body simulations, we demonstrate that the cosmological parameters can be estimated without bias. Our method is complementary to the baryon acoustic oscillation or topology methods as it depends on D{sub AH} , the product of the angular diameter distance and the Hubble parameter.« less

  15. Systematic Field Study of NO(x) Emission Control Methods for Utility Boilers.

    ERIC Educational Resources Information Center

    Bartok, William; And Others

    A utility boiler field test program was conducted. The objectives were to determine new or improved NO (x) emission factors by fossil fuel type and boiler design, and to assess the scope of applicability of combustion modification techniques for controlling NO (x) emissions from such installations. A statistically designed test program was…

  16. A Solar Energy Curriculum for Elementary Schools, Kindergarten Through Grade Six. Field Test Copy.

    ERIC Educational Resources Information Center

    Lampert, Seymour; And Others

    Presented is the field test version of an elementary school solar energy curriculum consisting of nearly 50 activities and demonstration experiments. Developed by a team of teachers and subject matter specialists, these materials are grouped under seven content area headings: (1) Scientific Method; (2) Energy and Life; (3) Sun and Light; (4)…

  17. An Examination of Teachers' Ratings of Lesson Plans Using Digital Primary Sources

    ERIC Educational Resources Information Center

    Milman, Natalie B.; Bondie, Rhonda

    2012-01-01

    This mixed method study examined teachers' ratings of 37 field-tested social studies lesson plans that incorporated digital primary sources through a grant from the Library of Congress Teaching with Primary Sources program for K-12 teachers. Each lesson, available in an online teaching materials collection, was field-tested and reviewed by at…

  18. Auralization of vibroacoustic models in engineering using Wave Field Synthesis: Application to plates and transmission loss

    NASA Astrophysics Data System (ADS)

    Bolduc, A.; Gauthier, P.-A.; Berry, A.

    2017-12-01

    While perceptual evaluation and sound quality testing with jury are now recognized as essential parts of acoustical product development, they are rarely implemented with spatial sound field reproduction. Instead, monophonic, stereophonic or binaural presentations are used. This paper investigates the workability and interest of a method to use complete vibroacoustic engineering models for auralization based on 2.5D Wave Field Synthesis (WFS). This method is proposed in order that spatial characteristics such as directivity patterns and direction-of-arrival are part of the reproduced sound field while preserving the model complete formulation that coherently combines frequency and spatial responses. Modifications to the standard 2.5D WFS operators are proposed for extended primary sources, affecting the reference line definition and compensating for out-of-plane elementary primary sources. Reported simulations and experiments of reproductions of two physically-accurate vibroacoustic models of thin plates show that the proposed method allows for an effective reproduction in the horizontal plane: Spatial and frequency domains features are recreated. Application of the method to the sound rendering of a virtual transmission loss measurement setup shows the potential of the method for use in virtual acoustical prototyping for jury testing.

  19. Methanogenic activity tests by Infrared Tunable Diode Laser Absorption Spectroscopy.

    PubMed

    Martinez-Cruz, Karla; Sepulveda-Jauregui, Armando; Escobar-Orozco, Nayeli; Thalasso, Frederic

    2012-10-01

    Methanogenic activity (MA) tests are commonly carried out to estimate the capability of anaerobic biomass to treat effluents, to evaluate anaerobic activity in bioreactors or natural ecosystems, or to quantify inhibitory effects on methanogenic activity. These activity tests are usually based on the measurement of the volume of biogas produced by volumetric, pressure increase or gas chromatography (GC) methods. In this study, we present an alternative method for non-invasive measurement of methane produced during activity tests in closed vials, based on Infrared Tunable Diode Laser Absorption Spectroscopy (MA-TDLAS). This new method was tested during model acetoclastic and hydrogenotrophic methanogenic activity tests and was compared to a more traditional method based on gas chromatography. From the results obtained, the CH(4) detection limit of the method was estimated to 60 ppm and the minimum measurable methane production rate was estimated to 1.09(.)10(-3) mg l(-1) h(-1), which is below CH(4) production rate usually reported in both anaerobic reactors and natural ecosystems. Additionally to sensitivity, the method has several potential interests compared to more traditional methods among which short measurements time allowing the measurement of a large number of MA test vials, non-invasive measurements avoiding leakage or external interferences and similar cost to GC based methods. It is concluded that MA-TDLAS is a promising method that could be of interest not only in the field of anaerobic digestion but also, in the field of environmental ecology where CH(4) production rates are usually very low. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Searching for Life with Rovers: Exploration Methods & Science Results from the 2004 Field Campaign of the "Life in the Atacama" Project and Applications to Future Mars Missions

    NASA Technical Reports Server (NTRS)

    Cabrol, N. A.a; Wettergreen, D. S.; Whittaker, R.; Grin, E. A.; Moersch, J.; Diaz, G. Chong; Cockell, C.; Coppin, P.; Dohm, J. M.; Fisher, G.

    2005-01-01

    The Life In The Atacama (LITA) project develops and field tests a long-range, solarpowered, automated rover platform (Zo ) and a science payload assembled to search for microbial life in the Atacama desert. Life is barely detectable over most of the driest desert on Earth. Its unique geological, climatic, and biological evolution have created a unique training site for designing and testing exploration strategies and life detection methods for the robotic search for life on Mars.

  1. A method for removing arm backscatter from EPID images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    King, Brian W.; Greer, Peter B.; School of Mathematical and Physical Sciences, University of Newcastle, Newcastle, New South Wales 2308

    2013-07-15

    Purpose: To develop a method for removing the support arm backscatter from images acquired using current Varian electronic portal imaging devices (EPIDs).Methods: The effect of arm backscatter on EPID images was modeled using a kernel convolution method. The parameters of the model were optimized by comparing on-arm images to off-arm images. The model was used to develop a method to remove the effect of backscatter from measured EPID images. The performance of the backscatter removal method was tested by comparing backscatter corrected on-arm images to measured off-arm images for 17 rectangular fields of different sizes and locations on the imager.more » The method was also tested using on- and off-arm images from 42 intensity modulated radiotherapy (IMRT) fields.Results: Images generated by the backscatter removal method gave consistently better agreement with off-arm images than images without backscatter correction. For the 17 rectangular fields studied, the root mean square difference of in-plane profiles compared to off-arm profiles was reduced from 1.19% (standard deviation 0.59%) on average without backscatter removal to 0.38% (standard deviation 0.18%) when using the backscatter removal method. When comparing to the off-arm images from the 42 IMRT fields, the mean {gamma} and percentage of pixels with {gamma} < 1 were improved by the backscatter removal method in all but one of the images studied. The mean {gamma} value (1%, 1 mm) for the IMRT fields studied was reduced from 0.80 to 0.57 by using the backscatter removal method, while the mean {gamma} pass rate was increased from 72.2% to 84.6%.Conclusions: A backscatter removal method has been developed to estimate the image acquired by the EPID without any arm backscatter from an image acquired in the presence of arm backscatter. The method has been shown to produce consistently reliable results for a wide range of field sizes and jaw configurations.« less

  2. Comparison of Diagnostic Accuracy between Octopus 900 and Goldmann Kinetic Visual Fields

    PubMed Central

    Rowe, Fiona J.; Rowlands, Alison

    2014-01-01

    Purpose. To determine diagnostic accuracy of kinetic visual field assessment by Octopus 900 perimetry compared with Goldmann perimetry. Methods. Prospective cross section evaluation of 40 control subjects with full visual fields and 50 patients with known visual field loss. Comparison of test duration and area measurement of isopters for Octopus 3, 5, and 10°/sec stimulus speeds. Comparison of test duration and type of visual field classification for Octopus versus Goldmann perimetry. Results were independently graded for presence/absence of field defect and for type and location of defect. Statistical evaluation comprised of ANOVA and paired t test for evaluation of parametric data with Bonferroni adjustment. Bland Altman and Kappa tests were used for measurement of agreement between data. Results. Octopus 5°/sec perimetry had comparable test duration to Goldmann perimetry. Octopus perimetry reliably detected type and location of visual field loss with visual fields matched to Goldmann results in 88.8% of results (K = 0.775). Conclusions. Kinetic perimetry requires individual tailoring to ensure accuracy. Octopus perimetry was reproducible for presence/absence of visual field defect. Our screening protocol when using Octopus perimetry is 5°/sec for determining boundaries of peripheral isopters and 3°/sec for blind spot mapping with further evaluation of area of field loss for defect depth and size. PMID:24587983

  3. Field kit and method for testing for the presence of gunshot residue

    DOEpatents

    Rodacy, Philip J.; Walker, Pamela K.

    2003-09-02

    A field test kit for gunshot residue comprises a container having at least compartments separated by a barrier. A surface is tested by wiping it with a swab and placing the swab in a first compartment. The barrier is then breached, permitting reagent in the second compartment to flow onto the swab. The first compartment is transparent, and a color change will be observed if the reagent reacts with gunshot residue.

  4. Validation of the virtual elevation field test method when assessing the aerodynamics of para-cyclists with a uni-lateral trans-tibial amputation.

    PubMed

    Dyer, Bryce; Disley, B Xavier

    2018-02-01

    Lower-limb amputees typically require some form of prosthetic limb to ride a bicycle for recreation or when competing. At elite-level racing speeds, aerodynamic drag can represent the majority of the resistance acting against a cyclists' forward motion. As a result, the reduction of such resistance is beneficial to an amputee whereby the form and function of the prosthetic limb can be optimized through engineering. To measure the performance of such limbs, field testing provides a cost-effective and context-specific method of aerodynamic drag measurement. However, few methods have been formally validated and none have been applied to amputees with lower-limb amputations. In this paper, an elite level para-cyclist wore two different prosthetic limb designs and had their total aerodynamic drag of a wind tunnel reference method statistically correlated against a velodrome-based virtual elevation field test method. The calculated coefficient of variation was in the range of 0.7-0.9% for the wind tunnel method and 2-3% for the virtual elevation method. A 0.03 m 2 difference was identified in the absolute values recorded between the two methods. Ultimately, both methods exhibited high levels of precision, yet relative results to each other. The virtual elevation method is proposed as a suitable technique to assess the aerodynamic drag of amputee para-cyclists. Implications for rehabilitation This assessment method will provide practitioners a reliable means of assessing the impact of changes made to prosthetics design for cyclists with limb absence. The proposed method offers a low cost and geographically accessible solution compared to others proposed in the past. This assessment method has significant potential for impact among prosthetic limb users looking to improve their cycling performance whereas previous attention in this field has been extremely limited.

  5. Using Educational Data Mining Methods to Assess Field-Dependent and Field-Independent Learners' Complex Problem Solving

    ERIC Educational Resources Information Center

    Angeli, Charoula; Valanides, Nicos

    2013-01-01

    The present study investigated the problem-solving performance of 101 university students and their interactions with a computer modeling tool in order to solve a complex problem. Based on their performance on the hidden figures test, students were assigned to three groups of field-dependent (FD), field-mixed (FM), and field-independent (FI)…

  6. TACCDAS Testbed Human Factors Evaluation Methodology,

    DTIC Science & Technology

    1980-03-01

    3 TEST METHOD Development of performance criteria................... 8 Test participant identification ...................... 8 Control of...major milestones involved in the evaluation process leading up to the evaluation of the complete testbed in the field are identified. Test methods and...inevitably will be different in several ways from the intended system as foreseen by the system designers. The system users provide insights into these

  7. A novel kit for rapid detection of Vibrio cholerae O1.

    PubMed

    Hasan, J A; Huq, A; Tamplin, M L; Siebeling, R J; Colwell, R R

    1994-01-01

    We report on the development and testing of a novel, rapid, colorimetric immunodiagnostic kit, Cholera SMART, for direct detection of the presence of Vibrio cholerae O1 in clinical specimens. Unlike conventional culture methods requiring several days to complete, the Cholera SMART kit can be used directly in the field by untrained or minimally skilled personnel to detect V. cholerae O1 in less than 15 min, without cumbersome laboratory equipment. A total of 120 clinical and environmental bacterial strains, including both O1 and non-O1 serotypes of V. cholerae isolated from samples collected from a variety of geographical regions, were tested, and positive reactions were observed only with V. cholerae O1. Also, results of a field trial in Bangladesh, employing Cholera SMART, showed 100% specificity and 96% sensitivity compared with conventional culture methods. Another field trial, in Mexico, showed that Cholera SMART was 100% in agreement with a recently described coagglutination test when 108 stool specimens were tested.

  8. Identification of characteristic frequencies of damaged railway tracks using field hammer test measurements

    NASA Astrophysics Data System (ADS)

    Oregui, M.; Li, Z.; Dollevoet, R.

    2015-03-01

    In this paper, the feasibility of the Frequency Response Function (FRF)-based statistical method to identify the characteristic frequencies of railway track defects is studied. The method compares a damaged track state to a healthy state based on non-destructive field hammer test measurements. First, a study is carried out to investigate the repeatability of hammer tests in railway tracks. By changing the excitation and measurement locations it is shown that the variability introduced by the test process is negligible. Second, following the concepts of control charts employed in process monitoring, a method to define an approximate healthy state is introduced by using hammer test measurements at locations without visual damage. Then, the feasibility study includes an investigation into squats (i.e. a major type of rail surface defect) of varying severity. The identified frequency ranges related to squats agree with those found in an extensively validated vehicle-borne detection system. Therefore, the FRF-based statistical method in combination with the non-destructive hammer test measurements has the potential to be employed to identify the characteristic frequencies of damaged conditions in railway tracks in the frequency range of 300-3000 Hz.

  9. Comparison of Different Measurement Technologies for the In-Flight Assessment of Radiated Acoustic Intensity

    NASA Technical Reports Server (NTRS)

    Klos, Jacob; Palumbo, Daniel L.; Buehrle, Ralph D.; Williams, Earl G.; Valdivia, Nicolas; Herdic, Peter C.; Sklanka, Bernard

    2005-01-01

    A series of tests was planned and conducted in the Interior Noise Test Facility at Boeing Field, on the NASA Aries 757 flight research aircraft, and in the Structural Acoustic Loads and Transmission Facility at NASA Langley Research Center. These tests were designed to answer several questions concerning the use of array methods in flight. One focus of the tests was determining whether and to what extent array methods could be used to identify the effects of an acoustical treatment applied to a limited portion of an aircraft fuselage. Another focus of the tests was to verify that the arrays could be used to localize and quantify a known source purposely placed in front of the arrays. Thus the issues related to backside sources and flanking paths present in the complicated sound field were addressed during these tests. These issues were addressed through the use of reference transducers, both accelerometers mounted to the fuselage and microphones in the cabin, that were used to correlate the pressure holograms. measured by the microphone arrays using either SVD methods or partial coherence methods. This correlation analysis accepts only energy that is coherent with the sources sensed by the reference transducers, allowing a noise control engineer to only identify and study those vibratory sources of interest. The remainder of this paper will present a detailed description of the test setups that were used in this test sequence and typical results of the NAH/IBEM analysis used to reconstruct the sound fields. Also, a comparison of data obtained in the laboratory environments and during flights of the 757 aircraft will be made.

  10. [Research progress on mechanical performance evaluation of artificial intervertebral disc].

    PubMed

    Li, Rui; Wang, Song; Liao, Zhenhua; Liu, Weiqiang

    2018-03-01

    The mechanical properties of artificial intervertebral disc (AID) are related to long-term reliability of prosthesis. There are three testing methods involved in the mechanical performance evaluation of AID based on different tools: the testing method using mechanical simulator, in vitro specimen testing method and finite element analysis method. In this study, the testing standard, testing equipment and materials of AID were firstly introduced. Then, the present status of AID static mechanical properties test (static axial compression, static axial compression-shear), dynamic mechanical properties test (dynamic axial compression, dynamic axial compression-shear), creep and stress relaxation test, device pushout test, core pushout test, subsidence test, etc. were focused on. The experimental techniques using in vitro specimen testing method and testing results of available artificial discs were summarized. The experimental methods and research status of finite element analysis were also summarized. Finally, the research trends of AID mechanical performance evaluation were forecasted. The simulator, load, dynamic cycle, motion mode, specimen and test standard would be important research fields in the future.

  11. T-duality constraints on higher derivatives revisited

    NASA Astrophysics Data System (ADS)

    Hohm, Olaf; Zwiebach, Barton

    2016-04-01

    We ask to what extent are the higher-derivative corrections of string theory constrained by T-duality. The seminal early work by Meissner tests T-duality by reduction to one dimension using a distinguished choice of field variables in which the bosonic string action takes a Gauss-Bonnet-type form. By analyzing all field redefinitions that may or may not be duality covariant and may or may not be gauge covariant we extend the procedure to test T-duality starting from an action expressed in arbitrary field variables. We illustrate the method by showing that it determines uniquely the first-order α' corrections of the bosonic string, up to terms that vanish in one dimension. We also use the method to glean information about the O({α}^' 2}) corrections in the double field theory with Green-Schwarz deformation.

  12. Improvements of the Profil Cultural Method for a better Low-tech Field Assessment of Soil Structure under no-till

    NASA Astrophysics Data System (ADS)

    Roger-Estrade, Jean; Boizard, Hubert; Peigné, Josephine; Sasal, Maria Carolina; Guimaraes, Rachel; Piron, Denis; Tomis, Vincent; Vian, Jean-François; Cadoux, Stephane; Ralisch, Ricardo; Filho, Tavares; Heddadj, Djilali; de Battista, Juan; Duparque, Annie

    2016-04-01

    In France, agronomists have studied the effects of cropping systems on soil structure, using a field method based on a visual description of soil structure. The "profil cultural" method (Manichon and Gautronneau, 1987) has been designed to perform a field diagnostic of the effects of tillage and compaction on soil structure dynamics. This method is of great use to agronomists improving crop management for a better preservation of soil structure. However, this method was developed and mainly used in conventional tillage systems, with ploughing. As several forms of reduced, minimum and no tillage systems are expanding in many parts of the world, it is necessary to re-evaluate the ability of this method to describe and interpret soil macrostructure in unploughed situations. In unploughed fields, soil structure dynamics of untilled layers is mainly driven by compaction and regeneration by natural agents (climatic conditions, root growth and macrofauna) and it is of major importance to evaluate the importance of these natural processes on soil structure regeneration. These concerns have led us to adapt the standard method and to propose amendments based on a series of field observations and experimental work in different situations of cropping systems, soil types and climatic conditions. We improved the description of crack type and we introduced an index of biological activity, based on the visual examination of clods. To test the improved method, a comparison with the reference method was carried out and the ability of the "profil cultural" method to make a diagnosis was tested on five experiments in France, Brazil and Argentina. Using the improved method, the impact of cropping systems on soil functioning was better assessed when natural processes were integrated into the description.

  13. A comparison of two adaptive multivariate analysis methods (PLSR and ANN) for winter wheat yield forecasting using Landsat-8 OLI images

    NASA Astrophysics Data System (ADS)

    Chen, Pengfei; Jing, Qi

    2017-02-01

    An assumption that the non-linear method is more reasonable than the linear method when canopy reflectance is used to establish the yield prediction model was proposed and tested in this study. For this purpose, partial least squares regression (PLSR) and artificial neural networks (ANN), represented linear and non-linear analysis method, were applied and compared for wheat yield prediction. Multi-period Landsat-8 OLI images were collected at two different wheat growth stages, and a field campaign was conducted to obtain grain yields at selected sampling sites in 2014. The field data were divided into a calibration database and a testing database. Using calibration data, a cross-validation concept was introduced for the PLSR and ANN model construction to prevent over-fitting. All models were tested using the test data. The ANN yield-prediction model produced R2, RMSE and RMSE% values of 0.61, 979 kg ha-1, and 10.38%, respectively, in the testing phase, performing better than the PLSR yield-prediction model, which produced R2, RMSE, and RMSE% values of 0.39, 1211 kg ha-1, and 12.84%, respectively. Non-linear method was suggested as a better method for yield prediction.

  14. Radar, target and ranging

    NASA Astrophysics Data System (ADS)

    1984-09-01

    This Test Operations Procedure (TOP) provides conventional test methods employing conventional test instrumentation for testing conventional radars. Single tests and subtests designed to test radar components, transmitters, receivers, antennas, etc., and system performance are conducted with single item instruments such as meters, generators, attenuators, counters, oscillators, plotters, etc., and with adequate land areas for conducting field tests.

  15. Advanced bridge safety initiative : recommended practices for live load testing of existing flat-slab concrete bridges - task 5.

    DOT National Transportation Integrated Search

    2012-12-01

    Current AASHTO provisions for load rating flat-slab concrete bridges use the equivalent strip : width method, which is regarded as overly conservative compared to more advanced analysis : methods and field live load testing. It has been shown that li...

  16. Nonlinear inversion of borehole-radar tomography data to reconstruct velocity and attenuation distribution in earth materials

    USGS Publications Warehouse

    Zhou, C.; Liu, L.; Lane, J.W.

    2001-01-01

    A nonlinear tomographic inversion method that uses first-arrival travel-time and amplitude-spectra information from cross-hole radar measurements was developed to simultaneously reconstruct electromagnetic velocity and attenuation distribution in earth materials. Inversion methods were developed to analyze single cross-hole tomography surveys and differential tomography surveys. Assuming the earth behaves as a linear system, the inversion methods do not require estimation of source radiation pattern, receiver coupling, or geometrical spreading. The data analysis and tomographic inversion algorithm were applied to synthetic test data and to cross-hole radar field data provided by the US Geological Survey (USGS). The cross-hole radar field data were acquired at the USGS fractured-rock field research site at Mirror Lake near Thornton, New Hampshire, before and after injection of a saline tracer, to monitor the transport of electrically conductive fluids in the image plane. Results from the synthetic data test demonstrate the algorithm computational efficiency and indicate that the method robustly can reconstruct electromagnetic (EM) wave velocity and attenuation distribution in earth materials. The field test results outline zones of velocity and attenuation anomalies consistent with the finding of previous investigators; however, the tomograms appear to be quite smooth. Further work is needed to effectively find the optimal smoothness criterion in applying the Tikhonov regularization in the nonlinear inversion algorithms for cross-hole radar tomography. ?? 2001 Elsevier Science B.V. All rights reserved.

  17. Full-field local displacement analysis of two-sided paperboard

    Treesearch

    J.M. Considine; D.W. Vahey

    2007-01-01

    This report describes a method to examine full-field displacements of both sides of paperboard during tensile testing. Analysis showed out-of-plane shear behavior near the failures zones. The method was reliably used to examine out-of-plane shear in double notch shear specimens. Differences in shear behavior of machine direction and cross-machine direction specimens...

  18. FIELD METHODS TO MEASURE CONTAMINANT REMOVAL EFFECTIVENESS OF GAS-PHASE AIR FILTRATION EQUIPMENT - PHASE 1: SEARCH OF LITERATURE AND PRIOR ART

    EPA Science Inventory

    The report, Phase 1 of a two-phase research project, gives results of a literature search into the
    effectiveness of in-field gas-phase air filtration equipment (GPAFE) test methods, including required instrumentation and costs. GPAFE has been used in heating, ventilation, and ...

  19. The research of collapsibility test and FEA of collapse deformation in loess collapsible under overburden pressure

    NASA Astrophysics Data System (ADS)

    yu, Zhang; hui, Li; guibo, Bao; wuyu, Zhang; ningshan, Jiang; xiaoyun, Yang

    2018-05-01

    The collapsibility test in field may have huge error with computed results[1-4]. The writer gave a compare between single-line and double-line method and then compared with the field’s result. The writer’s purpose is to reduce the error of measured value to computed value and propose a way to decrease the error through consider the matric suction’s influence to unsaturated soil in using finite element analysis, field test was completed to verify the reasonability of this method and get some regulate of development of collapse deformation and supply some calculation basis of engineering design and forecast in emergency situation.

  20. Decomposition of Magnetic Field Boundary Conditions into Parts Produced by Internal and External Sources

    NASA Astrophysics Data System (ADS)

    Lazanja, David; Boozer, Allen

    2006-10-01

    Given the total magnetic field on a toroidal plasma surface, a method for decomposing the field into a part due to internal currents (often the plasma) and a part due to external currents is presented. The method exploits Laplace theory which is valid in the vacuum region between the plasma surface and the chamber walls. The method is developed for the full three dimensional case which is necessary for studying stellarator plasma configurations. A change in the plasma shape is produced by the total normal field perturbation on the plasma surface. This method allows a separation of the total normal field perturbation into a part produced by external currents and a part produced by the plasma response. There are immediate applications to coil design. The computational procedure is based on Merkel's 1986 work on vacuum field computations. Several test cases are presented for toroidal surfaces which verify the method and computational robustness of the code.

  1. A new gradient shimming method based on undistorted field map of B0 inhomogeneity.

    PubMed

    Bao, Qingjia; Chen, Fang; Chen, Li; Song, Kan; Liu, Zao; Liu, Chaoyang

    2016-04-01

    Most existing gradient shimming methods for NMR spectrometers estimate field maps that resolve B0 inhomogeneity spatially from dual gradient-echo (GRE) images acquired at different echo times. However, the distortions induced by B0 inhomogeneity that always exists in the GRE images can result in estimated field maps that are distorted in both geometry and intensity, leading to inaccurate shimming. This work proposes a new gradient shimming method based on undistorted field map of B0 inhomogeneity obtained by a more accurate field map estimation technique. Compared to the traditional field map estimation method, this new method exploits both the positive and negative polarities of the frequency encoded gradients to eliminate the distortions caused by B0 inhomogeneity in the field map. Next, the corresponding automatic post-data procedure is introduced to obtain undistorted B0 field map based on knowledge of the invariant characteristics of the B0 inhomogeneity and the variant polarity of the encoded gradient. The experimental results on both simulated and real gradient shimming tests demonstrate the high performance of this new method. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Measurement of spatio-temporal field distribution of THz pulses in electro-optic crystal by interferometry method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chizhov, P A; Ushakov, A A; Bukin, V V

    2015-05-31

    We propose a scheme for measuring the spatial distribution of the THz pulse electric field strength in an electro-optic crystal using optical interferometry. The resulting images of the field distribution from a test source with a spherical wave front are presented. (extreme light fields and their applications)

  3. Characterization for elastic constants of fused deposition modelling-fabricated materials based on the virtual fields method and digital image correlation

    NASA Astrophysics Data System (ADS)

    Cao, Quankun; Xie, Huimin

    2017-12-01

    Fused deposition modelling (FDM), a widely used rapid prototyping process, is a promising technique in manufacturing engineering. In this work, a method for characterizing elastic constants of FDM-fabricated materials is proposed. First of all, according to the manufacturing process of FDM, orthotropic constitutive model is used to describe the mechanical behavior. Then the virtual fields method (VFM) is applied to characterize all the mechanical parameters (Q_{11}, Q_{22}, Q_{12}, Q_{66}) using the full-field strain, which is measured by digital image correlation (DIC). Since the principal axis of the FDM-fabricated structure is sometimes unknown due to the complexity of the manufacturing process, a disk in diametrical compression is used as the load configuration so that the loading angle can be changed conveniently. To verify the feasibility of the proposed method, finite element method (FEM) simulation is conducted to obtain the strain field of the disk. The simulation results show that higher accuracy can be achieved when the loading angle is close to 30°. Finally, a disk fabricated by FDM was used for the experiment. By rotating the disk, several tests with different loading angles were conducted. To determine the position of the principal axis in each test, two groups of parameters (Q_{11}, Q_{22}, Q_{12}, Q_{66}) are calculated by two different groups of virtual fields. Then the corresponding loading angle can be determined by minimizing the deviation between two groups of the parameters. After that, the four constants (Q_{11}, Q_{22}, Q_{12}, Q_{66}) were determined from the test with an angle of 27°.

  4. Evaluation of clinical methods for peroneal muscle testing.

    PubMed

    Sarig-Bahat, Hilla; Krasovsky, Andrei; Sprecher, Elliot

    2013-03-01

    Manual muscle testing of the peroneal muscles is well accepted as a testing method in musculoskeletal physiotherapy for the assessment of the foot and ankle. The peroneus longus and brevis are primary evertors and secondary plantar flexors of the ankle joint. However, some international textbooks describe them as dorsi flexors, when instructing peroneal muscle testing. The identified variability raised a question whether these educational texts are reflected in the clinical field. The purposes of this study were to investigate what are the methods commonly used in the clinical field for peroneal muscle testing and to evaluate their compatibility with functional anatomy. A cross-sectional study was conducted, using an electronic questionnaire sent to 143 Israeli physiotherapists in the musculoskeletal field. The survey questioned on the anatomical location of manual resistance and the combination of motions resisted. Ninety-seven responses were received. The majority (69%) of respondents related correctly to the peronei as evertors, but asserted that resistance should be located over the dorsal aspect of the fifth metatarsus, thereby disregarding the peroneus longus. Moreover, 38% of the respondents described the peronei as dorsi flexors, rather than plantar flexors. Only 2% selected the correct method of resisting plantarflexion and eversion at the base of the first metatarsus. We consider this technique to be the most compatible with the anatomy of the peroneus longus and brevis. The Fisher-Freeman-Halton test indicated that there was a significant relationship between responses on the questions (P = 0.0253, 95% CI 0.0249-0.0257), thus justifying further correspondence analysis. The correspondence analysis found no clustering of the answers that were compatible with anatomical evidence and were applied in the correct technique, but did demonstrate a common error, resisting dorsiflexion rather than plantarflexion, which was in agreement with the described frequencies. Inconsistencies were identified between the instruction method commonly provided for peroneal muscle testing in textbook and the functional anatomy of these muscles. Results reflect the lack of accuracy in applying functional anatomy to peroneal testing. This may be due to limited use of peroneal muscle testing or to inadequate investigation of the existing evaluation methods and their validity. Accordingly, teaching materials and clinical methods used for this test should be re-evaluated. Further research should investigate the value of peroneal muscle testing in clinical ankle evaluation. Copyright © 2012 John Wiley & Sons, Ltd.

  5. Beta Testing StraboSpot: Perspectives on mobile field mapping and data collection

    NASA Astrophysics Data System (ADS)

    Bunse, E.; Graham, K. A.; Rufledt, C.; Walker, J. D.; Müller, A.; Tikoff, B.

    2017-12-01

    Geologic field mapping has recently transitioned away from traditional techniques (e.g. field notebooks, paper mapping, Brunton compasses) and towards mobile `app' mapping technology. The StraboSpot system (Strabo) is an open-source solution for collection and storage for geologic field, microstructural, and lab-based data. Strabo's mission is to "enable recording and sharing data within the geoscience community, encourage interdisciplinary research, and facilitate the investigation of scientific questions that cannot currently be addressed" (Walker et al., 2015). Several mobile application beta tests of the system, on both Android and Apple iOS platforms using smartphones and tablets, began in Summer 2016. Students at the 2016 and 2017 University of Kansas Field Camps used Strabo in place of ArcGIS for Desktop on Panasonic Toughbooks, to field map two study areas. Strabo was also field tested by students of graduate and undergraduate level for both geo/thermochronologic sample collection and reconnaissance mapping associated with regional tectonic analysis in California. Throughout this period of testing, the app was geared toward structural and tectonic geologic data collection, but is versatile enough for other communities to currently use and is expanding to accommodate the sedimentology and petrology communities. Overall, users in each of the beta tests acclimated quickly to using Strabo for field data collection. Some key advantages to using Strabo over traditional mapping methods are: (1) Strabo allows for consolidation of materials in the field; (2) helps students track their position in the field with integrated GPS; and (3) Strabo data is in a uniform format making it simple for geologists to collaborate. While traditional field methods are not likely to go out of style in the near future, Strabo acts as a bridge between professional and novice geologists by providing a tool that is intuitive on all levels of geological and technological experience and allows for more effective collaboration in the field. Walker, J. Douglas, et al. (2015), Development of Structural Geology and Tectonics Data System with Field and Lab Interface, Abstract IN21E-04 presented at 2015 Fall Meeting, AGU, San Francisco, Calif., 14-18 Dec.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    McLellan, G.W.

    This test plan describes the field demonstration of the sonic drilling system being conducted as a coordinated effort between the VOC-Arid ID (Integrated Demonstration) and the 200 West Area Carbon Tetrachloride ERA (Expedited Response Action) programs at Hanford. The purpose of this test is to evaluate the Water Development Corporation`s drilling system, modify components as necessary and determine compatible drilling applications for the sonic drilling method for use at facilities in the DOE complex. The sonic demonstration is being conducted as the first field test under the Cooperative Research and Development Agreement (CRADA) which involves the US Department of Energy,more » Pacific Northwest Laboratory, Westinghouse Hanford Company and Water Development Corporation. The sonic drilling system will be used to drill a 45 degree vadose zone well, two vertical wells at the VOC-Arid ID site, and several test holes at the Drilling Technology Test Site north of the 200 Area fire station. Testing at other locations will depend on the performance of the drilling method. Performance of this technology will be compared to the baseline drilling method (cable-tool).« less

  7. FIELD CHECK MANUAL FOR LANGUAGE LABORATORIES, A SERIES OF TESTS WHICH A NON-TECHNICAL PERSON CAN CONDUCT TO VERIFY SPECIFICATIONS.

    ERIC Educational Resources Information Center

    GRITTNER, FRANK; PAVLAT, RUSSELL

    IN ORDER TO ASSIST NON-TECHNICAL PEOPLE IN SCHOOLS TO CONDUCT A FIELD CHECK OF LANGUAGE LABORATORY EQUIPMENT BEFORE THEY MAKE FINAL PAYMENTS, THIS MANUAL OFFERS CRITERIA, TESTS, AND METHODS OF SCORING THE QUALITY OF THE EQUIPMENT. CHECKLISTS ARE PROVIDED FOR EVALUATING CONSOLE FUNCTIONS, TAPE RECORDERS, AMPLIFIERS, SOUND QUALITY (INCLUDING…

  8. Hydraulic analysis of harmonic pumping tests in frequency and time domains for identifying the conduits networks in a karstic aquifer

    NASA Astrophysics Data System (ADS)

    Fischer, P.; Jardani, A.; Cardiff, M.; Lecoq, N.; Jourde, H.

    2018-04-01

    In a karstic field, the flow paths are very complex as they globally follow the conduit network. The responses generated from an investigation in this type of aquifer can be spatially highly variable. Therefore, the aim of the investigation in this case is to define a degree of connectivity between points of the field, in order to understand these flow paths. Harmonic pumping tests represent a possible investigation method for characterizing the subsurface flow of groundwater. They have several advantages compared to a constant-rate pumping (more signal possibilities, ease of extracting the signal in the responses and possibility of closed loop investigation). We show in this work that interpreting the responses from a harmonic pumping test is very useful for delineating a degree of connectivity between measurement points. We have firstly studied the amplitude and phase offset of responses from a harmonic pumping test in a theoretical synthetic modeling case in order to define a qualitative interpretation method in the time and frequency domains. Three different type of responses have been separated: a conduit connectivity response, a matrix connectivity, and a dual connectivity (response of a point in the matrix, but close to a conduit). We have then applied this method to measured responses at a field research site. Our interpretation method permits a quick and easy reconstruction of the main flow paths, and the whole set of field responses appear to give a similar range of responses to those seen in the theoretical synthetic case.

  9. Grain growth prediction based on data assimilation by implementing 4DVar on multi-phase-field model

    NASA Astrophysics Data System (ADS)

    Ito, Shin-ichi; Nagao, Hiromichi; Kasuya, Tadashi; Inoue, Junya

    2017-12-01

    We propose a method to predict grain growth based on data assimilation by using a four-dimensional variational method (4DVar). When implemented on a multi-phase-field model, the proposed method allows us to calculate the predicted grain structures and uncertainties in them that depend on the quality and quantity of the observational data. We confirm through numerical tests involving synthetic data that the proposed method correctly reproduces the true phase-field assumed in advance. Furthermore, it successfully quantifies uncertainties in the predicted grain structures, where such uncertainty quantifications provide valuable information to optimize the experimental design.

  10. A comparative evaluation of in-plane shear test methods for laminated graphite-epoxy composites

    NASA Technical Reports Server (NTRS)

    Morton, John; Ho, Henjen

    1992-01-01

    The objectives were to evaluate popular shear test methods for various forms of graphite-epoxy composite materials and to determine the shear response of graphite-epoxy composites with various forms of fiber architecture. Numerical and full-field experimental stress analyses were performed on four shear test configurations for unidirectional and bidirectional graphite-epoxy laminates to assess the uniformity and purity of the shear stress (strain) fields produced in the specimen test section and to determine the material in-plane shear modulus and shear response. The test methods were the 10 deg off-axis, the +/- 45 deg tension, the Iosipescu V-notch, and a compact U-notch specimen. Specimens were prepared from AS4/3501-6 graphite-epoxy panels, instrumented with conventional strain gage rosettes and with a cross-line moire grating, and loaded in a convenient testing machine. The shear responses obtained for each test method and the two methods of specimen instrumentation were compared. In a second phase of the program the shear responses obtained from Iosipescu V-notch beam specimens were determined for woven fabric geometries of different weave and fiber architectures. Again the responses of specimens obtained from strain gage rosettes and moire interferometry were compared. Additional experiments were performed on a bidirectional cruciform specimen which was also instrumented with strain gages and a moire grating.

  11. Vibrational multiconfiguration self-consistent field theory: implementation and test calculations.

    PubMed

    Heislbetz, Sandra; Rauhut, Guntram

    2010-03-28

    A state-specific vibrational multiconfiguration self-consistent field (VMCSCF) approach based on a multimode expansion of the potential energy surface is presented for the accurate calculation of anharmonic vibrational spectra. As a special case of this general approach vibrational complete active space self-consistent field calculations will be discussed. The latter method shows better convergence than the general VMCSCF approach and must be considered the preferred choice within the multiconfigurational framework. Benchmark calculations are provided for a small set of test molecules.

  12. A Method for Testing the Dynamic Accuracy of Micro-Electro-Mechanical Systems (MEMS) Magnetic, Angular Rate, and Gravity (MARG) Sensors for Inertial Navigation Systems (INS) and Human Motion Tracking Applications

    DTIC Science & Technology

    2010-06-01

    32 2. Low-Cost Framework........................................................................33 3. Low Magnetic Field ...that have a significant impact on the magnetic field measured by a MARG, which could potentially add errors that are due entirely to the test...minimize the impact on the local magnetic field , and the apparatus was made as rigidly as possible using 2 x 4s to minimize any out of plane motions that

  13. Charged-Particle Transport in the Data-Driven, Non-Isotropic Turbulent Mangetic Field in the Solar Wind

    NASA Astrophysics Data System (ADS)

    Sun, P.; Jokipii, J. R.; Giacalone, J.

    2016-12-01

    Anisotropies in astrophysical turbulence has been proposed and observed for a long time. And recent observations adopting the multi-scale analysis techniques provided a detailed description of the scale-dependent power spectrum of the magnetic field parallel and perpendicular to the scale-dependent magnetic field line at different scales in the solar wind. In the previous work, we proposed a multi-scale method to synthesize non-isotropic turbulent magnetic field with pre-determined power spectra of the fluctuating magnetic field as a function of scales. We present the effect of test particle transport in the resulting field with a two-scale algorithm. We find that the scale-dependent turbulence anisotropy has a significant difference in the effect on charged par- ticle transport from what the isotropy or the global anisotropy has. It is important to apply this field synthesis method to the solar wind magnetic field based on spacecraft data. However, this relies on how we extract the power spectra of the turbulent magnetic field across different scales. In this study, we propose here a power spectrum synthesis method based on Fourier analysis to extract the large and small scale power spectrum from a single spacecraft observation with a long enough period and a high sampling frequency. We apply the method to the solar wind measurement by the magnetometer onboard the ACE spacecraft and regenerate the large scale isotropic 2D spectrum and the small scale anisotropic 2D spectrum. We run test particle simulations in the magnetid field generated in this way to estimate the transport coefficients and to compare with the isotropic turbulence model.

  14. A method for the modelling of porous and solid wind tunnel walls in computational fluid dynamics codes

    NASA Technical Reports Server (NTRS)

    Beutner, Thomas John

    1993-01-01

    Porous wall wind tunnels have been used for several decades and have proven effective in reducing wall interference effects in both low speed and transonic testing. They allow for testing through Mach 1, reduce blockage effects and reduce shock wave reflections in the test section. Their usefulness in developing computational fluid dynamics (CFD) codes has been limited, however, by the difficulties associated with modelling the effect of a porous wall in CFD codes. Previous approaches to modelling porous wall effects have depended either upon a simplified linear boundary condition, which has proven inadequate, or upon detailed measurements of the normal velocity near the wall, which require extensive wind tunnel time. The current work was initiated in an effort to find a simple, accurate method of modelling a porous wall boundary condition in CFD codes. The development of such a method would allow data from porous wall wind tunnels to be used more readily in validating CFD codes. This would be beneficial when transonic validations are desired, or when large models are used to achieve high Reynolds numbers in testing. A computational and experimental study was undertaken to investigate a new method of modelling solid and porous wall boundary conditions in CFD codes. The method utilized experimental measurements at the walls to develop a flow field solution based on the method of singularities. This flow field solution was then imposed as a pressure boundary condition in a CFD simulation of the internal flow field. The effectiveness of this method in describing the effect of porosity changes on the wall was investigated. Also, the effectiveness of this method when only sparse experimental measurements were available has been investigated. The current work demonstrated this approach for low speed flows and compared the results with experimental data obtained from a heavily instrumented variable porosity test section. The approach developed was simple, computationally inexpensive, and did not require extensive or intrusive measurements of the boundary conditions during the wind tunnel test. It may be applied to both solid and porous wall wind tunnel tests.

  15. Determination of Magnetic Parameters of Maghemite (γ-Fe2O3) Core-Shell Nanoparticles from Nonlinear Magnetic Susceptibility Measurements

    NASA Astrophysics Data System (ADS)

    Syvorotka, Ihor I.; Pavlyk, Lyubomyr P.; Ubizskii, Sergii B.; Buryy, Oleg A.; Savytskyy, Hrygoriy V.; Mitina, Nataliya Y.; Zaichenko, Oleksandr S.

    2017-04-01

    Method of determining of magnetic moment and size from measurements of dependence of the nonlinear magnetic susceptibility upon magnetic field is proposed, substantiated and tested for superparamagnetic nanoparticles (SPNP) of the "magnetic core-polymer shell" type which are widely used in biomedical technologies. The model of the induction response of the SPNP ensemble on the combined action of the magnetic harmonic excitation field and permanent bias field is built, and the analysis of possible ways to determine the magnetic moment and size of the nanoparticles as well as the parameters of the distribution of these variables is performed. Experimental verification of the proposed method was implemented on samples of SPNP with maghemite core in dry form as well as in colloidal systems. The results have been compared with the data obtained by other methods. Advantages of the proposed method are analyzed and discussed, particularly in terms of its suitability for routine express testing of SPNP for biomedical technology.

  16. An IMU Evaluation Method Using a Signal Grafting Scheme

    PubMed Central

    Niu, Xiaoji; Wang, Qiang; Li, You; Zhang, Quan; Jiang, Peng

    2016-01-01

    As various inertial measurement units (IMUs) from different manufacturers appear every year, it is not affordable to evaluate every IMU through tests. Therefore, this paper presents an IMU evaluation method by grafting data from the tested IMU to the reference data from a higher-grade IMU. The signal grafting (SG) method has several benefits: (a) only one set of field tests with a higher-grade IMU is needed, and can be used to evaluate numerous IMUs. Thus, SG is effective and economic because all data from the tested IMU is collected in the lab; (b) it is a general approach to compare navigation performances of various IMUs by using the same reference data; and, finally, (c) through SG, one can first evaluate an IMU in the lab, and then decide whether to further test it. Moreover, this paper verified the validity of SG to both medium- and low-grade IMUs, and presents and compared two SG strategies, i.e., the basic-error strategy and the full-error strategy. SG provided results similar to field tests, with a difference of under 5% and 19.4%–26.7% for tested tactical-grade and MEMS IMUs. Meanwhile, it was found that dynamic IMU errors were essential to guarantee the effect of the SG method. PMID:27294932

  17. Fluxgate magnetometer offset vector determination by the 3D mirror mode method

    NASA Astrophysics Data System (ADS)

    Plaschke, F.; Goetz, C.; Volwerk, M.; Richter, I.; Frühauff, D.; Narita, Y.; Glassmeier, K.-H.; Dougherty, M. K.

    2017-07-01

    Fluxgate magnetometers on-board spacecraft need to be regularly calibrated in flight. In low fields, the most important calibration parameters are the three offset vector components, which represent the magnetometer measurements in vanishing ambient magnetic fields. In case of three-axis stabilized spacecraft, a few methods exist to determine offsets: (I) by analysis of Alfvénic fluctuations present in the pristine interplanetary magnetic field, (II) by rolling the spacecraft around at least two axes, (III) by cross-calibration against measurements from electron drift instruments or absolute magnetometers, and (IV) by taking measurements in regions of well-known magnetic fields, e.g. cometary diamagnetic cavities. In this paper, we introduce a fifth option, the 3-dimensional (3D) mirror mode method, by which 3D offset vectors can be determined using magnetic field measurements of highly compressional waves, e.g. mirror modes in the Earth's magnetosheath. We test the method by applying it to magnetic field data measured by the following: the Time History of Events and Macroscale Interactions during Substorms-C spacecraft in the terrestrial magnetosheath, the Cassini spacecraft in the Jovian magnetosheath and the Rosetta spacecraft in the vicinity of comet 67P/Churyumov-Gerasimenko. The tests reveal that the achievable offset accuracies depend on the ambient magnetic field strength (lower strength meaning higher accuracy), on the length of the underlying data interval (more data meaning higher accuracy) and on the stability of the offset that is to be determined.

  18. Bias correction for magnetic resonance images via joint entropy regularization.

    PubMed

    Wang, Shanshan; Xia, Yong; Dong, Pei; Luo, Jianhua; Huang, Qiu; Feng, Dagan; Li, Yuanxiang

    2014-01-01

    Due to the imperfections of the radio frequency (RF) coil or object-dependent electrodynamic interactions, magnetic resonance (MR) images often suffer from a smooth and biologically meaningless bias field, which causes severe troubles for subsequent processing and quantitative analysis. To effectively restore the original signal, this paper simultaneously exploits the spatial and gradient features of the corrupted MR images for bias correction via the joint entropy regularization. With both isotropic and anisotropic total variation (TV) considered, two nonparametric bias correction algorithms have been proposed, namely IsoTVBiasC and AniTVBiasC. These two methods have been applied to simulated images under various noise levels and bias field corruption and also tested on real MR data. The test results show that the proposed two methods can effectively remove the bias field and also present comparable performance compared to the state-of-the-art methods.

  19. Alkali content of fly ash : measuring and testing strategies for compliance : [tech transfer summary].

    DOT National Transportation Integrated Search

    2015-04-01

    This study investigated the test methods used to determine the : alkali content of fly ash. It also evaluated if high-alkali fly ash : exacerbates alkali-silica reaction in laboratory tests and field : concrete.

  20. Development of the mathematical model for design and verification of acoustic modal analysis methods

    NASA Astrophysics Data System (ADS)

    Siner, Alexander; Startseva, Maria

    2016-10-01

    To reduce the turbofan noise it is necessary to develop methods for the analysis of the sound field generated by the blade machinery called modal analysis. Because modal analysis methods are very difficult and their testing on the full scale measurements are very expensive and tedious it is necessary to construct some mathematical models allowing to test modal analysis algorithms fast and cheap. At this work the model allowing to set single modes at the channel and to analyze generated sound field is presented. Modal analysis of the sound generated by the ring array of point sound sources is made. Comparison of experimental and numerical modal analysis results is presented at this work.

  1. Visual field progression in glaucoma: total versus pattern deviation analyses.

    PubMed

    Artes, Paul H; Nicolela, Marcelo T; LeBlanc, Raymond P; Chauhan, Balwantray C

    2005-12-01

    To compare visual field progression with total and pattern deviation analyses in a prospective longitudinal study of patients with glaucoma and healthy control subjects. A group of 101 patients with glaucoma (168 eyes) with early to moderately advanced visual field loss at baseline (average mean deviation [MD], -3.9 dB) and no clinical evidence of media opacity were selected from a prospective longitudinal study on visual field progression in glaucoma. Patients were examined with static automated perimetry at 6-month intervals for a median follow-up of 9 years. At each test location, change was established with event and trend analyses of total and pattern deviation. The event analyses compared each follow-up test to a baseline obtained from averaging the first two tests, and visual field progression was defined as deterioration beyond the 5th percentile of test-retest variability at three test locations, observed on three consecutive tests. The trend analyses were based on point-wise linear regression, and visual field progression was defined as statistically significant deterioration (P < 5%) worse than -1 dB/year at three locations, confirmed by independently omitting the last and the penultimate observation. The incidence and the time-to-progression were compared between total and pattern deviation analyses. To estimate the specificity of the progression analyses, identical criteria were applied to visual fields obtained in 102 healthy control subjects, and the rate of visual field improvement was established in the patients with glaucoma and the healthy control subjects. With both event and trend methods, pattern deviation analyses classified approximately 15% fewer eyes as having progressed than did the total deviation analyses. In eyes classified as progressing by both the total and pattern deviation methods, total deviation analyses tended to detect progression earlier than the pattern deviation analyses. A comparison of the changes observed in MD and the visual fields' general height (estimated by the 85th percentile of the total deviation values) confirmed that change in the glaucomatous eyes almost always comprised a diffuse component. Pattern deviation analyses of progression may therefore underestimate the true amount of glaucomatous visual field progression. Pattern deviation analyses of visual field progression may underestimate visual field progression in glaucoma, particularly when there is no clinical evidence of increasing media opacity. Clinicians should have access to both total and pattern deviation analyses to make informed decisions on visual field progression in glaucoma.

  2. Effects of 60-Heartz electric and magnetic fields on implanted cardiac pacemakers. Final report. [Hazards of power transmission line frequencies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bridges, J.E.; Frazier, M.J.

    1979-09-01

    The effects of 60-Hz electric and magnetic fields of exta-high voltage (EHV) transmission lines on the performance of implanted cardiac pacemakers were studied by: (1) in vitro bench tests of a total of thirteen cardiac pacemakers; (2) in vivo tests of six implanted cardiac pacemakers in baboons; and (3) non-hazardous skin measurement tests on four humans. Analytical methods were developed to predict the thresholds of body current and electric fields capable of affecting normal pacemaker operation in humans. The field strengths calculated to alter implanted pacemaker performance were compared with the range of maximum electric and magnetic field strengths amore » human would normally encounter under transmission lines of various voltages. Results indicate that the electric field or body current necessary to alter the normal operation of pacemakers is highly dependent on the type of pacemaker and the location of the implanted electrodes. However, cardiologists have not so far detected harmful effects of pacemaker reversion to the asynchronous mode in current types of pacemakers and with present methods of implantation. Such interferences can be eliminated by using advanced pacemakers less sensitive to 60-Hz voltages or by using implantation lead arrangements less sensitive to body current.« less

  3. SU-F-T-547: Off-Isocenter Winston-Lutz Test for Stereotactic Radiosurgery/stereotactic Body Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gao, J; Liu, X

    2016-06-15

    Purpose: To perform a quantitative study to verify that the mechanical field center coincides with the radiation field center when both are off from the isocenter during the single-isocenter technique in linear accelerator-based SRS/SBRT procedure to treat multiple lesions. Methods: We developed an innovative method to measure this accuracy, called the off-isocenter Winston-Lutz test, and here we provide a practical clinical guideline to implement this technique. We used ImagePro V.6 to analyze images of a Winston-Lutz phantom obtained using a Varian 21EX linear accelerator with an electronic portal imaging device, set up as for single-isocenter SRS/SBRT for multiple lesions. Wemore » investigated asymmetry field centers that were 3 cm and 5 cm away from the isocenter, as well as performing the standard Winston-Lutz test. We used a special beam configuration to acquire images while avoiding collision, and we investigated both jaw and multileaf collimation. Results: For the jaw collimator setting, at 3 cm off-isocenter, the mechanical field deviated from the radiation field by about 2.5 mm; at 5 cm, the deviation was above 3 mm, up to 4.27 mm. For the multileaf collimator setting, at 3 cm off-isocenter, the deviation was below 1 mm; at 5 cm, the deviation was above 1 mm, up to 1.72 mm, which is 72% higher than the tolerance threshold. Conclusion: These results indicated that the further the asymmetry field center is from the machine isocenter, the larger the deviation of the mechanical field from the radiation field, and the distance between the center of the asymmetry field and the isocenter should not exceed 3 cm in of our clinic. We recommend that every clinic that uses linear accelerator, multileaf collimator-based SRS/SBRT perform the off-isocenter Winston-Lutz test in addition to the standard Winston-Lutz test and use their own deviation data to design the treatment plan.« less

  4. Mode-Stirred Method Implementation for HIRF Susceptibility Testing and Results Comparison with Anechoic Method

    NASA Technical Reports Server (NTRS)

    Nguyen, Truong X.; Ely, Jay J.; Koppen, Sandra V.

    2001-01-01

    This paper describes the implementation of mode-stirred method for susceptibility testing according to the current DO-160D standard. Test results on an Engine Data Processor using the implemented procedure and the comparisons with the standard anechoic test results are presented. The comparison experimentally shows that the susceptibility thresholds found in mode-stirred method are consistently higher than anechoic. This is consistent with the recent statistical analysis finding by NIST that the current calibration procedure overstates field strength by a fixed amount. Once the test results are adjusted for this value, the comparisons with the anechoic results are excellent. The results also show that test method has excellent chamber to chamber repeatability. Several areas for improvements to the current procedure are also identified and implemented.

  5. On the prediction of far field computational aeroacoustics of advanced propellers

    NASA Technical Reports Server (NTRS)

    Jaeger, Stephen M.; Korkan, Kenneth D.

    1990-01-01

    A numerical method for determining the acoustic far field generated by a high-speed subsonic aircraft propeller was developed. The approach used in this method was to generate the entire three-dimensional pressure field about the propeller (using an Euler flowfield solver) and then to apply a solution of the wave equation on a cylindrical surface enveloping the propeller. The method is applied to generate the three-dimensional flowfield between two blades of an advanced propeller. The results are compared with experimental data obtained in a wind-tunnel test at a Mach number of 0.6.

  6. Rapid test methods for the evaluation of concrete properties.

    DOT National Transportation Integrated Search

    1982-01-01

    The objective of the project was to place a CERL/Kelly-Vail testing unit and a microwave oven in the field to perform tests of plastic concrete on construction projects. : The CERL/K-V tests were to determine water and cement content of the concrete ...

  7. Geostatistical radar-raingauge combination with nonparametric correlograms: methodological considerations and application in Switzerland

    NASA Astrophysics Data System (ADS)

    Schiemann, R.; Erdin, R.; Willi, M.; Frei, C.; Berenguer, M.; Sempere-Torres, D.

    2011-05-01

    Modelling spatial covariance is an essential part of all geostatistical methods. Traditionally, parametric semivariogram models are fit from available data. More recently, it has been suggested to use nonparametric correlograms obtained from spatially complete data fields. Here, both estimation techniques are compared. Nonparametric correlograms are shown to have a substantial negative bias. Nonetheless, when combined with the sample variance of the spatial field under consideration, they yield an estimate of the semivariogram that is unbiased for small lag distances. This justifies the use of this estimation technique in geostatistical applications. Various formulations of geostatistical combination (Kriging) methods are used here for the construction of hourly precipitation grids for Switzerland based on data from a sparse realtime network of raingauges and from a spatially complete radar composite. Two variants of Ordinary Kriging (OK) are used to interpolate the sparse gauge observations. In both OK variants, the radar data are only used to determine the semivariogram model. One variant relies on a traditional parametric semivariogram estimate, whereas the other variant uses the nonparametric correlogram. The variants are tested for three cases and the impact of the semivariogram model on the Kriging prediction is illustrated. For the three test cases, the method using nonparametric correlograms performs equally well or better than the traditional method, and at the same time offers great practical advantages. Furthermore, two variants of Kriging with external drift (KED) are tested, both of which use the radar data to estimate nonparametric correlograms, and as the external drift variable. The first KED variant has been used previously for geostatistical radar-raingauge merging in Catalonia (Spain). The second variant is newly proposed here and is an extension of the first. Both variants are evaluated for the three test cases as well as an extended evaluation period. It is found that both methods yield merged fields of better quality than the original radar field or fields obtained by OK of gauge data. The newly suggested KED formulation is shown to be beneficial, in particular in mountainous regions where the quality of the Swiss radar composite is comparatively low. An analysis of the Kriging variances shows that none of the methods tested here provides a satisfactory uncertainty estimate. A suitable variable transformation is expected to improve this.

  8. Geostatistical radar-raingauge combination with nonparametric correlograms: methodological considerations and application in Switzerland

    NASA Astrophysics Data System (ADS)

    Schiemann, R.; Erdin, R.; Willi, M.; Frei, C.; Berenguer, M.; Sempere-Torres, D.

    2010-09-01

    Modelling spatial covariance is an essential part of all geostatistical methods. Traditionally, parametric semivariogram models are fit from available data. More recently, it has been suggested to use nonparametric correlograms obtained from spatially complete data fields. Here, both estimation techniques are compared. Nonparametric correlograms are shown to have a substantial negative bias. Nonetheless, when combined with the sample variance of the spatial field under consideration, they yield an estimate of the semivariogram that is unbiased for small lag distances. This justifies the use of this estimation technique in geostatistical applications. Various formulations of geostatistical combination (Kriging) methods are used here for the construction of hourly precipitation grids for Switzerland based on data from a sparse realtime network of raingauges and from a spatially complete radar composite. Two variants of Ordinary Kriging (OK) are used to interpolate the sparse gauge observations. In both OK variants, the radar data are only used to determine the semivariogram model. One variant relies on a traditional parametric semivariogram estimate, whereas the other variant uses the nonparametric correlogram. The variants are tested for three cases and the impact of the semivariogram model on the Kriging prediction is illustrated. For the three test cases, the method using nonparametric correlograms performs equally well or better than the traditional method, and at the same time offers great practical advantages. Furthermore, two variants of Kriging with external drift (KED) are tested, both of which use the radar data to estimate nonparametric correlograms, and as the external drift variable. The first KED variant has been used previously for geostatistical radar-raingauge merging in Catalonia (Spain). The second variant is newly proposed here and is an extension of the first. Both variants are evaluated for the three test cases as well as an extended evaluation period. It is found that both methods yield merged fields of better quality than the original radar field or fields obtained by OK of gauge data. The newly suggested KED formulation is shown to be beneficial, in particular in mountainous regions where the quality of the Swiss radar composite is comparatively low. An analysis of the Kriging variances shows that none of the methods tested here provides a satisfactory uncertainty estimate. A suitable variable transformation is expected to improve this.

  9. Do we really need in-situ bioassays?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salazar, M.H.; Salazar, S.M.

    1995-12-31

    In-situ bioassays are needed to validate the results from laboratory testing and to understand biological interactions. Standard laboratory protocols provide reproducible test results, and the precision of those tests can be mathematically defined. Significant correlations between toxic substances and levels of response (bioaccumulation and bioeffects) have also been demonstrated with natural field populations and suggest that the laboratory results can accurately predict field responses. An equal number of studies have shown a lack of correlation between laboratory bioassay results and responses of natural field populations. The best way to validate laboratory results is with manipulative field testing; i.e., in-situ bioassaysmore » with caged organisms. Bioaccumulation in transplanted bivalves has probably been the most frequently used form of an in-situ bioassay. The authors have refined those methods to include synoptic measurements of bioaccumulation and growth. Growth provides an easily-measured bioeffects endpoint and a means of calibrating bioaccumulation. Emphasis has been on minimizing the size range of test animals, repetitive measurements of individuals and standardization of test protocols for a variety of applications. They are now attempting to standardize criteria for accepting and interpreting data in the same way that laboratory bioassays have been standardized. Others have developed methods for in-situ bioassays using eggs, larvae, unicellular organisms, crustaceans, benthic invertebrates, bivalves, and fish. In the final analysis, the in-situ approach could be considered as an exposure system where any clinical measurements are possible. The most powerful approach would be to use the same species in laboratory and field experiments with the same endpoints.« less

  10. Comparison of sampling and test methods for determining asphalt content and moisture correction in asphalt concrete mixtures.

    DOT National Transportation Integrated Search

    1985-03-01

    The purpose of this report is to identify the difference, if any, in AASHTO and OSHD test procedures and results. This report addresses the effect of the size of samples taken in the field and evaluates the methods of determining the moisture content...

  11. Analysis of Slug Tests in Formations of High Hydraulic Conductivity

    USGS Publications Warehouse

    Butler, J.J.; Garnett, E.J.; Healey, J.M.

    2003-01-01

    A new procedure is presented for the analysis of slug tests performed in partially penetrating wells in formations of high hydraulic conductivity. This approach is a simple, spreadsheet-based implementation of existing models that can be used for analysis of tests from confined or unconfined aquifers. Field examples of tests exhibiting oscillatory and nonoscillatory behavior are used to illustrate the procedure and to compare results with estimates obtained using alternative approaches. The procedure is considerably simpler than recently proposed methods for this hydrogeologic setting. Although the simplifications required by the approach can introduce error into hydraulic-conductivity estimates, this additional error becomes negligible when appropriate measures are taken in the field. These measures are summarized in a set of practical field guidelines for slug tests in highly permeable aquifers.

  12. Analysis of slug tests in formations of high hydraulic conductivity.

    PubMed

    Butler, James J; Garnett, Elizabeth J; Healey, John M

    2003-01-01

    A new procedure is presented for the analysis of slug tests performed in partially penetrating wells in formations of high hydraulic conductivity. This approach is a simple, spreadsheet-based implementation of existing models that can be used for analysis of tests from confined or unconfined aquifers. Field examples of tests exhibiting oscillatory and nonoscillatory behavior are used to illustrate the procedure and to compare results with estimates obtained using alternative approaches. The procedure is considerably simpler than recently proposed methods for this hydrogeologic setting. Although the simplifications required by the approach can introduce error into hydraulic-conductivity estimates, this additional error becomes negligible when appropriate measures are taken in the field. These measures are summarized in a set of practical field guidelines for slug tests in highly permeable aquifers.

  13. Woodstove smoke and CO emissions: comparison of reference methods with the VIP sampler.

    PubMed

    Jaasma, D R; Champion, M C; Shelton, J W

    1990-06-01

    A new field sampler has been developed for measuring the particulate matter (PM) and carbon monoxide emissions of woodburning stoves. Particulate matter is determined by carbon balance and the workup of a sample train which is similar to a room-temperature EPA Method 5G train. A steel tank, initially evacuated, serves as the motive force for sampling and also accumulates a gas sample for post-test analysis of time-averaged stack CO and CO2 concentrations. Workup procedures can be completed within 72 hours of sampler retrieval. The system has been compared to reference methods in two laboratory test series involving six different woodburning appliances and two independent laboratories. The correlation of field sampler emission rates and reference method rates is strong.

  14. Woodstove smoke and CO emissions: Comparison of reference methods with the VIP sampler

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jaasma, D.R.; Champion, M.C.; Shelton, J.W.

    1990-06-01

    A new field sampler has been developed for measuring the particulate matter (PM) and carbon monoxide emissions of woodburning stoves. Particulate matter is determined by carbon balance and the workup of a sample train which is similar to a room-temperature EPA Method 5G train. A steel tank, initially evacuated, serves as the motive force for sampling and also accumulates a gas sample for post-test analysis of time-averaged stack CO and CO{sub 2} concentrations. Workup procedures can be completed within 72 hours of sampler retrieval. The system has been compared to reference methods in two laboratory test series involving six differentmore » woodburning appliances and two independent laboratories. The correlation of field sampler emission rates and reference method rates is strong.« less

  15. Experimental Investigation of Textile Composite Materials Using Moire Interferometry

    NASA Technical Reports Server (NTRS)

    Ifju, Peter G.

    1995-01-01

    The viability as an efficient aircraft material of advanced textile composites is currently being addressed in the NASA Advanced Composites Technology (ACT) Program. One of the expected milestones of the program is to develop standard test methods for these complex material systems. Current test methods for laminated composites may not be optimum for textile composites, since the architecture of the textile induces nonuniform deformation characteristics on the scale of the smallest repeating unit of the architecture. The smallest repeating unit, also called the unit cell, is often larger than the strain gages used for testing of tape composites. As a result, extending laminated composite test practices to textiles can often lead to pronounced scatter in material property measurements. It has been speculated that the fiber architectures produce significant surface strain nonuniformities, however, the magnitudes were not well understood. Moire interferometry, characterized by full-field information, high displacement sensitivity, and high spatial resolution, is well suited to document the surface strain on textile composites. Studies at the NASA Langley Research Center on a variety of textile architectures including 2-D braids and 3-D weaves, has evidenced the merits of using moire interferometry to guide in test method development for textile composites. Moire was used to support tensile testing by validating instrumentation practices and documenting damage mechanisms. It was used to validate shear test methods by mapping the full-field deformation of shear specimens. Moire was used to validate open hole tension experiments to determine the strain concentration and compare then to numeric predictions. It was used for through-the-thickness tensile strength test method development, to verify capabilities for testing of both 2-D and 3-D material systems. For all of these examples, moire interferometry provided vision so that test methods could be developed with less speculation and more documentation.

  16. Active tower damping and pitch balancing - design, simulation and field test

    NASA Astrophysics Data System (ADS)

    Duckwitz, Daniel; Shan, Martin

    2014-12-01

    The tower is one of the major components in wind turbines with a contribution to the cost of energy of 8 to 12% [1]. In this overview the load situation of the tower will be described in terms of sources of loads, load components and fatigue contribution. Then two load reduction control schemes are described along with simulation and field test results. Pitch Balancing is described as a method to reduce aerodynamic asymmetry and the resulting fatigue loads. Active Tower Damping is reducing the tower oscillations by applying appropiate pitch angle changes. A field test was conducted on an Areva M5000 wind turbine.

  17. Field assessment of dried Plasmodium falciparum samples for malaria rapid diagnostic test quality control and proficiency testing in Ethiopia.

    PubMed

    Tamiru, Afework; Boulanger, Lucy; Chang, Michelle A; Malone, Joseph L; Aidoo, Michael

    2015-01-21

    Rapid diagnostic tests (RDTs) are now widely used for laboratory confirmation of suspected malaria cases to comply with the World Health Organization recommendation for universal testing before treatment. However, many malaria programmes lack quality control (QC) processes to assess RDT use under field conditions. Prior research showed the feasibility of using the dried tube specimen (DTS) method for preserving Plasmodium falciparum parasites for use as QC samples for RDTs. This study focused on the use of DTS for RDT QC and proficiency testing under field conditions. DTS were prepared using cultured P. falciparum at densities of 500 and 1,000 parasites/μL; 50 μL aliquots of these along with parasite negative human blood controls (0 parasites/μL) were air-dried in specimen tubes and reactivity verified after rehydration. The DTS were used in a field study in the Oromia Region of Ethiopia. Replicate DTS samples containing 0, 500 and 1,000 parasites/μL were stored at 4°C at a reference laboratory and at ambient temperatures at two nearby health facilities. At weeks 0, 4, 8, 12, 16, 20, and 24, the DTS were rehydrated and tested on RDTs stored under manufacturer-recommended temperatures at the RL and on RDTs stored under site-specific conditions at the two health facilities. Reactivity of DTS stored at 4°C at the reference laboratory on RDTs stored at the reference laboratory was considered the gold standard for assessing DTS stability. A proficiency-testing panel consisting of one negative and three positive samples, monitored with a checklist was administered at weeks 12 and 24. At all the seven time points, DTS stored at both the reference laboratory and health facility were reactive on RDTs stored under the recommended temperature and under field conditions, and the DTS without malaria parasites were negative. At the reference laboratory and one health facility, a 500 parasites/μL DTS from the proficiency panel was falsely reported as negative at week 24 due to errors in interpreting faint test lines. The DTS method can be used under field conditions to supplement other RDT QC methods and health worker proficiency in Ethiopia and possibly other malaria-endemic countries.

  18. FDTD simulation of field performance in reverberation chamber excited by two excitation antennas

    NASA Astrophysics Data System (ADS)

    Wang, Song; Wu, Zhan-cheng; Cui, Yao-zhong

    2013-03-01

    The excitation source is one of the critical items that determine the electromagnetic fields in a reverberation chamber (RC). In order to optimize the electromagnetic fields performance, a new method of exciting RC with two antennas is proposed based on theoretical analysis. The full 3D simulation of RC is carried out by the finite difference time domain (FDTD) method on two excitation conditions of one antenna and two antennas. The broadband response of RC is obtained by fast Fourier transformation (FFT) after only one simulation. Numerical data show that the field uniformity in the test space is improved on the condition of two transmitting antennas while the normalized electric fields decreased slightly compared to the one antenna condition. It is straightforward to recognize that two antennas excitation can reduce the demands on power amplifier as the total input power is split among the two antennas, and consequently the cost of electromagnetic compatibility (EMC) test in large-scale RC can be reduced.

  19. Extra high speed modified Lundell alternator parameters and open/short-circuit characteristics from global 3D-FE magnetic field solutions

    NASA Astrophysics Data System (ADS)

    Wang, R.; Demerdash, N. A.

    1992-06-01

    The combined magnetic vector potential - magnetic scalar potential method of computation of 3D magnetic fields by finite elements, introduced in a companion paper, is used for global 3D field analysis and machine performance computations under open-circuit and short-circuit conditions for an example 14.3 kVA modified Lundell alternator, whose magnetic field is of intrinsic 3D nature. The computed voltages and currents under these machine test conditions were verified and found to be in very good agreement with corresponding test data. Results of use of this modelling and computation method in the study of a design alteration example, in which the stator stack length of the example alternator is stretched in order to increase voltage and volt-ampere rating, are given here. These results demonstrate the inadequacy of conventional 2D-based design concepts and the imperative of use of this type of 3D magnetic field modelling in the design and investigation of such machines.

  20. Extra high speed modified Lundell alternator parameters and open/short-circuit characteristics from global 3D-FE magnetic field solutions

    NASA Technical Reports Server (NTRS)

    Wang, R.; Demerdash, N. A.

    1992-01-01

    The combined magnetic vector potential - magnetic scalar potential method of computation of 3D magnetic fields by finite elements, introduced in a companion paper, is used for global 3D field analysis and machine performance computations under open-circuit and short-circuit conditions for an example 14.3 kVA modified Lundell alternator, whose magnetic field is of intrinsic 3D nature. The computed voltages and currents under these machine test conditions were verified and found to be in very good agreement with corresponding test data. Results of use of this modelling and computation method in the study of a design alteration example, in which the stator stack length of the example alternator is stretched in order to increase voltage and volt-ampere rating, are given here. These results demonstrate the inadequacy of conventional 2D-based design concepts and the imperative of use of this type of 3D magnetic field modelling in the design and investigation of such machines.

  1. Image-optimized Coronal Magnetic Field Models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, Shaela I.; Uritsky, Vadim; Davila, Joseph M., E-mail: shaela.i.jones-mecholsky@nasa.gov, E-mail: shaela.i.jonesmecholsky@nasa.gov

    We have reported previously on a new method we are developing for using image-based information to improve global coronal magnetic field models. In that work, we presented early tests of the method, which proved its capability to improve global models based on flawed synoptic magnetograms, given excellent constraints on the field in the model volume. In this follow-up paper, we present the results of similar tests given field constraints of a nature that could realistically be obtained from quality white-light coronagraph images of the lower corona. We pay particular attention to difficulties associated with the line-of-sight projection of features outsidemore » of the assumed coronagraph image plane and the effect on the outcome of the optimization of errors in the localization of constraints. We find that substantial improvement in the model field can be achieved with these types of constraints, even when magnetic features in the images are located outside of the image plane.« less

  2. Detection of concrete dam leakage using an integrated geophysical technique based on flow-field fitting method

    NASA Astrophysics Data System (ADS)

    Dai, Qianwei; Lin, Fangpeng; Wang, Xiaoping; Feng, Deshan; Bayless, Richard C.

    2017-05-01

    An integrated geophysical investigation was performed at S dam located at Dadu basin in China to assess the condition of the dam curtain. The key methodology of the integrated technique used was flow-field fitting method, which allowed identification of the hydraulic connections between the dam foundation and surface water sources (upstream and downstream), and location of the anomalous leakage outlets in the dam foundation. Limitations of the flow-field fitting method were complemented with resistivity logging to identify the internal erosion which had not yet developed into seepage pathways. The results of the flow-field fitting method and resistivity logging were consistent when compared with data provided by seismic tomography, borehole television, water injection test, and rock quality designation.

  3. Flat-fielding of Solar Hα Observations Based on the Maximum Correntropy Criterion

    NASA Astrophysics Data System (ADS)

    Xu, Gao-Gui; Zheng, Sheng; Lin, Gang-Hua; Wang, Xiao-Fan

    2016-08-01

    The flat-field CCD calibration method of Kuhn et al. (KLL) is an efficient method for flat-fielding. However, since it depends on the minimum of the sum of squares error (SSE), its solution is sensitive to noise, especially non-Gaussian noise. In this paper, a new algorithm is proposed to determine the flat field. The idea is to change the criterion of gain estimate from SSE to the maximum correntropy. The result of a test on simulated data demonstrates that our method has a higher accuracy and a faster convergence than KLL’s and Chae’s. It has been found that the method effectively suppresses noise, especially in the case of typical non-Gaussian noise. And the computing time of our algorithm is the shortest.

  4. Direct Field Acoustic Testing

    NASA Technical Reports Server (NTRS)

    Larkin, Paul; Goldstein, Bob

    2008-01-01

    This paper presents an update to the methods and procedures used in Direct Field Acoustic Testing (DFAT). The paper will discuss some of the recent techniques and developments that are currently being used and the future publication of a reference standard. Acoustic testing using commercial sound system components is becoming a popular and cost effective way of generating a required acoustic test environment both in and out of a reverberant chamber. This paper will present the DFAT test method, the usual setup and procedure and the development and use of a closed-loop, narrow-band control system. Narrow-band control of the acoustic PSD allows all standard techniques and procedures currently used in random control to be applied to acoustics and some examples are given. The paper will conclude with a summary of the development of a standard practice guideline that is hoped to be available in the first quarter of next year.

  5. Comparability between various field and laboratory wood-stove emission-measurement methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCrillis, R.C.; Jaasma, D.R.

    1991-01-01

    The paper compares various field and laboratory woodstove emission measurement methods. In 1988, the U.S. EPA promulgated performance standards for residential wood heaters (woodstoves). Over the past several years, a number of field studies have been undertaken to determine the actual level of emission reduction achieved by new technology woodstoves in everyday use. The studies have required the development and use of particulate and gaseous emission sampling equipment compatible with operation in private homes. Since woodstoves are tested for certification in the laboratory using EPA Methods 5G and 5H, it is of interest to determine the correlation between these regulatorymore » methods and the inhouse equipment. Two inhouse sampling systems have been used most widely: one is an intermittent, pump-driven particulate sampler that collects particulate and condensible organics on a filter and organic adsorbent resin; and the other uses an evacuated cylinder as the motive force and particulate and condensible organics are collected in a condenser and dual filter. Both samplers can operate unattended for 1-week periods. A large number of tests have been run comparing Methods 5G and 5H to both samplers. The paper presents these comparison data and determines the relationships between regulations and field samplers.« less

  6. [Current status of gene test market].

    PubMed

    Ohtani, Shinichi

    2002-12-01

    The technological innovation of the gene analysis makes the adaptation range of the gene test in clinical diagnosis expand. Then, gene test has popularized increasingly around the infection disease for clinical inspection. Also in the field of clinical inspection, the increase of the importance of clinical application and the inspection item new year by year have appeared with the functional analysis of a gene. Moreover, the new test method and automation analysis equipment tend to be developed by progress of gene-analysis technology, and it is going to be introduced. The spread of gene test and development of a gene test market have an important possibility of activating the present clinical inspection field.

  7. Inter-laboratory Comparison of Three Earplug Fit-test Systems

    PubMed Central

    Byrne, David C.; Murphy, William J.; Krieg, Edward F.; Ghent, Robert M.; Michael, Kevin L.; Stefanson, Earl W.; Ahroon, William A.

    2017-01-01

    The National Institute for Occupational Safety and Health (NIOSH) sponsored tests of three earplug fit-test systems (NIOSH HPD Well-Fit™, Michael & Associates FitCheck, and Honeywell Safety Products VeriPRO®). Each system was compared to laboratory-based real-ear attenuation at threshold (REAT) measurements in a sound field according to ANSI/ASA S12.6-2008 at the NIOSH, Honeywell Safety Products, and Michael & Associates testing laboratories. An identical study was conducted independently at the U.S. Army Aeromedical Research Laboratory (USAARL), which provided their data for inclusion in this report. The Howard Leight Airsoft premolded earplug was tested with twenty subjects at each of the four participating laboratories. The occluded fit of the earplug was maintained during testing with a soundfield-based laboratory REAT system as well as all three headphone-based fit-test systems. The Michael & Associates lab had highest average A-weighted attenuations and smallest standard deviations. The NIOSH lab had the lowest average attenuations and the largest standard deviations. Differences in octave-band attenuations between each fit-test system and the American National Standards Institute (ANSI) sound field method were calculated (Attenfit-test - AttenANSI). A-weighted attenuations measured with FitCheck and HPD Well-Fit systems demonstrated approximately ±2 dB agreement with the ANSI sound field method, but A-weighted attenuations measured with the VeriPRO system underestimated the ANSI laboratory attenuations. For each of the fit-test systems, the average A-weighted attenuation across the four laboratories was not significantly greater than the average of the ANSI sound field method. Standard deviations for residual attenuation differences were about ±2 dB for FitCheck and HPD Well-Fit compared to ±4 dB for VeriPRO. Individual labs exhibited a range of agreement from less than a dB to as much as 9.4 dB difference with ANSI and REAT estimates. Factors such as the experience of study participants and test administrators, and the fit-test psychometric tasks are suggested as possible contributors to the observed results. PMID:27786602

  8. Development and Field Test of the Modified Draw-a-Scientist Test and the Draw-a-Scientist Rubric

    ERIC Educational Resources Information Center

    Farland-Smith, Donna

    2012-01-01

    Even long before children are able to verbalize which careers may be interesting to them, they collect and store ideas about scientists. For these reasons, asking children to draw a scientist has become an accepted method to provide a glimpse into how children represent and identify with those in the science fields. Years later, these…

  9. Numerical simulation on residual stress in Y-slit type cracking test of Q690E

    NASA Astrophysics Data System (ADS)

    Huang, Wenjian; Lin, Guozhen; Chen, Zhanglan; Chen, Wu

    2018-03-01

    Numerical simulation on residual stress in Y-slit type cracking test of Q690E is carried out by using ANSYS. First, the dynamic distribution of welding temperature field is calculated; second, the results of the temperature field are converted into corresponding stress by the method of indirect coupling. The testing results show that the longitudinal residual stress of the weld is greater than the transverse residual stress and the peak of transverse residual stress is on the weld groove.

  10. Correlating the EMC analysis and testing methods for space systems in MIL-STD-1541A

    NASA Technical Reports Server (NTRS)

    Perez, Reinaldo J.

    1990-01-01

    A study was conducted to improve the correlation between the electromagnetic compatibility (EMC) analysis models stated in MIL-STD-1541A and the suggested testing methods used for space systems. The test and analysis methods outlined in MIL-STD-1541A are described, and a comparative assessment of testing and analysis techniques as they relate to several EMC areas is presented. Suggestions on present analysis and test methods are introduced to harmonize and bring the analysis and testing tools in MIL-STD-1541A into closer agreement. It is suggested that test procedures in MIL-STD-1541A must be improved by providing alternatives to the present use of shielded enclosures as the primary site for such tests. In addition, the alternate use of anechoic chambers and open field test sites must be considered.

  11. 45 CFR 1388.6 - Program criteria-services and supports.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... according to accepted practices of scientific evaluation; (iv) Research methods that are used to test hypotheses, validate procedures, and field test projects; and (v) Direct service and project practices and...

  12. Measurement environments and testing

    NASA Astrophysics Data System (ADS)

    Marvin, A. C.

    1991-06-01

    The various methods used to assess both the emission (interference generation) performance of electronic equipment and the immunity of electronic equipment to external electromagnetic interference are described. The measurement methods attempt to simulate realistic operating conditions for the equipment being tested, yet at the same time they must be repeatable and practical to operate. This has led to the development of a variety of test methods, each of which has its limitations. Concentration is on the most common measurement methods such as open-field test sites, screened enclosures and transverse electromagnetic (TEM) cells. The physical justification for the methods, their limitations, and measurement precision are described. Ways of relating similar measurements made by different methods are discussed, and some thoughts on future measurement improvements are presented.

  13. Comparing Standard and Selective Degradation DNA Extraction Methods: Results from a Field Experiment with Sexual Assault Kits.

    PubMed

    Campbell, Rebecca; Pierce, Steven J; Sharma, Dhruv B; Shaw, Jessica; Feeney, Hannah; Nye, Jeffrey; Schelling, Kristin; Fehler-Cabral, Giannina

    2017-01-01

    A growing number of U.S. cities have large numbers of untested sexual assault kits (SAKs) in police property facilities. Testing older kits and maintaining current case work will be challenging for forensic laboratories, creating a need for more efficient testing methods. We evaluated selective degradation methods for DNA extraction using actual case work from a sample of previously unsubmitted SAKs in Detroit, Michigan. We randomly assigned 350 kits to either standard or selective degradation testing methods and then compared DNA testing rates and CODIS entry rates between the two groups. Continuation-ratio modeling showed no significant differences, indicating that the selective degradation method had no decrement in performance relative to customary methods. Follow-up equivalence tests indicated that CODIS entry rates for the two methods could differ by more than ±5%. Selective degradation methods required less personnel time for testing and scientific review than standard testing. © 2016 American Academy of Forensic Sciences.

  14. Analgesic, antibacterial and central nervous system depressant activities of Albizia procera leaves.

    PubMed

    Khatoon, Mst Mahfuza; Khatun, Mst Hajera; Islam, Md Ekramul; Parvin, Mst Shahnaj

    2014-04-01

    To ascertain analgesic, antibacterial and central nervous system (CNS) depressant activities of ethyl acetate, dichloromethane and carbon tetrachloride fractions of methanol extract of Albizia procera (A. procera) leaves. Leaves extracts of A. procera were tested for analgesic activity by acetic acid induced and formalin test method in mice. The in vitro antibacterial activity was performed by agar well diffusion method. CNS depressant activity was evaluated by hole cross and open field tests. All the extracts at 200 mg/kg exhibited significant (P<0.01) analgesic activity in acetic acid induced and formalin tests method in mice. Analgesic activity of the ethyl acetate fraction was almost same like as standard drug indomethacin in acetic acid induced method. The CNS depressant activity of the extracts at 500 mg/kg was comparable to the positive control diazepam as determined by hole cross and open field test method. The extracts exhibited moderate antimicrobial activity against all the tested microorganisms (Staphylococcus aureus, Bacillus cereus, Pseudomonas aeruginosa, Esherichia coli, Shigella soneii, Shigella boydii) at concentration of 0.8 mg/disc. The measured diameter of zone of inhibition for the extracts was within the range of 7 to 12 mm which was less than the standard kanamycin (16-24 mm). It is concluded that all the extracts possess potential analgesic and CNS depressants activity. This study also showed that different fractions of methanol extract could be potential sources of new antimicrobial agents.

  15. Creating a testing field where delta technology and water innovations are tested and demonstrated with the help of citizen science methods

    NASA Astrophysics Data System (ADS)

    de Vries, Sandra; Rutten, Martine; de Vries, Liselotte; Anema, Kim; Klop, Tanja; Kaspersma, Judith

    2017-04-01

    In highly populated deltas, much work is to be done. Complex problems ask for new and knowledge driven solutions. Innovations in delta technology and water can bring relief to managing the water rich urban areas. Testing fields form a fundamental part of the knowledge valorisation for such innovations. In such testing fields, product development by start-ups is coupled with researchers, thus supplying new scientific insights. With the help of tests, demonstrations and large-scale applications by the end-users, these innovations find their way to the daily practices of delta management. More and more cities embrace the concept of Smart Cities to tackle the ongoing complexity of urban problems and to manage the city's assets - such as its water supply networks and other water management infrastructure. Through the use of new technologies and innovative systems, data are collected from and with citizens and devices - then processed and analysed. The information and knowledge gathered are keys to enabling a better quality of life. By testing water innovations together with citizens in order to find solutions for water management problems, not only highly spatial amounts of data are provided by and/or about these innovations, they are also improved and demonstrated to the public. A consortium consisting of a water authority, a science centre, a valorisation program and two universities have joined forces to create a testing field for delta technology and water innovations using citizen science methods. In this testing field, the use of citizen science for water technologies is researched and validated by facilitating pilot projects. In these projects, researchers, start-ups and citizens work together to find the answer to present-day water management problems. The above mentioned testing field tests the use of crowd-sourcing data as for example hydrological model inputs, or to validate remote sensing applications, or improve water management decisions. Currently the testing field starts two pilot projects concerning (1) the validation of green measures used for water storage in order to better quantify their worth, and (2) the collection of water quality data in a polder polluted by horticulture in such manner that water management and awareness are improved.

  16. Visual field defects after temporal lobe resection for epilepsy.

    PubMed

    Steensberg, Alvilda T; Olsen, Ane Sophie; Litman, Minna; Jespersen, Bo; Kolko, Miriam; Pinborg, Lars H

    2018-01-01

    To determine visual field defects (VFDs) using methods of varying complexity and compare results with subjective symptoms in a population of newly operated temporal lobe epilepsy patients. Forty patients were included in the study. Two patients failed to perform VFD testing. Humphrey Field Analyzer (HFA) perimetry was used as the gold standard test to detect VFDs. All patients performed a web-based visual field test called Damato Multifixation Campimetry Online (DMCO). A bedside confrontation visual field examination ad modum Donders was extracted from the medical records in 27/38 patients. All participants had a consultation by an ophthalmologist. A questionnaire described the subjective complaints. A VFD in the upper quadrant was demonstrated with HFA in 29 (76%) of the 38 patients after surgery. In 27 patients tested ad modum Donders, the sensitivity of detecting a VFD was 13%. Eight patients (21%) had a severe VFD similar to a quadrant anopia, thus, questioning their permission to drive a car. In this group of patients, a VFD was demonstrated in one of five (sensitivity=20%) ad modum Donders and in seven of eight (sensitivity=88%) with DMCO. Subjective symptoms were only reported by 28% of the patients with a VFD and in two of eight (sensitivity=25%) with a severe VFD. Most patients (86%) considered VFD information mandatory. VFD continue to be a frequent adverse event after epilepsy surgery in the medial temporal lobe and may affect the permission to drive a car in at least one in five patients. Subjective symptoms and bedside visual field testing ad modum Donders are not sensitive to detect even a severe VFD. Newly developed web-based visual field test methods appear sensitive to detect a severe VFD but perimetry remains the golden standard for determining if visual standards for driving is fulfilled. Patients consider VFD information as mandatory. Copyright © 2017. Published by Elsevier Ltd.

  17. Characterization of the onboard imaging unit for the first clinical magnetic resonance image guided radiation therapy system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu, Yanle, E-mail: Hu.Yanle@mayo.edu; Rankine, Leith; Green, Olga L.

    Purpose: To characterize the performance of the onboard imaging unit for the first clinical magnetic resonance image guided radiation therapy (MR-IGRT) system. Methods: The imaging performance characterization included four components: ACR (the American College of Radiology) phantom test, spatial integrity, coil signal to noise ratio (SNR) and uniformity, and magnetic field homogeneity. The ACR phantom test was performed in accordance with the ACR phantom test guidance. The spatial integrity test was evaluated using a 40.8 × 40.8 × 40.8 cm{sup 3} spatial integrity phantom. MR and computed tomography (CT) images of the phantom were acquired and coregistered. Objects were identifiedmore » around the surfaces of 20 and 35 cm diameters of spherical volume (DSVs) on both the MR and CT images. Geometric distortion was quantified using deviation in object location between the MR and CT images. The coil SNR test was performed according to the national electrical manufacturers association (NEMA) standards MS-1 and MS-9. The magnetic field homogeneity test was measured using field camera and spectral peak methods. Results: For the ACR tests, the slice position error was less than 0.10 cm, the slice thickness error was less than 0.05 cm, the resolved high-contrast spatial resolution was 0.09 cm, the resolved low-contrast spokes were more than 25, the image intensity uniformity was above 93%, and the percentage ghosting was less than 0.22%. All were within the ACR recommended specifications. The maximum geometric distortions within the 20 and 35 cm DSVs were 0.10 and 0.18 cm for high spatial resolution three-dimensional images and 0.08 and 0.20 cm for high temporal resolution two dimensional cine images based on the distance-to-phantom-center method. The average SNR was 12.0 for the body coil, 42.9 for the combined torso coil, and 44.0 for the combined head and neck coil. Magnetic field homogeneities at gantry angles of 0°, 30°, 60°, 90°, and 120° were 23.55, 20.43, 18.76, 19.11, and 22.22 ppm, respectively, using the field camera method over the 45 cm DSV. Conclusions: The onboard imaging unit of the first commercial MR-IGRT system meets ACR, NEMA, and vendor specifications.« less

  18. The relationship between human field motion and preferred visible wavelengths.

    PubMed

    Benedict, S C; Burge, J M

    1990-01-01

    The purpose of this study was to investigate the relationship between human field motion and preferred visible wavelengths. The study was based on the principle of resonancy from Rogers' science of unitary human beings; 201 subjects were tested using a modified version of Ference's human field motion test (HFMT). Two matrices of color were projected to provide an environment for the measurement of preferred visible wavelengths. There was no statistically significant relationship (r = 0.0387, p = 0.293) between scores on the human field motion test and preferred visible wavelengths as measured in nanometers. The Rogerian concept of accelerated human field rhythms being coordinate with higher frequency environment patterns was not supported in this study. Questions concerning the validity of the HFMT were expressed and were based upon the ambiguity of the terminology of the instrument and the lack of understanding of the concepts used to describe human field motion. Recommendations include the use of other methods to study Rogers' framework, and the development of other instrumentation to measure human field motion.

  19. Hazardous material transportation safety and security field operational test final evaluation plan : executive summary

    DOT National Transportation Integrated Search

    2003-03-17

    The purpose of this effort is to independently evaluate the Battelle Operational Test Team to test methods for leveraging technology and operations to improve HAZMAT transport security, safety, and operational efficiency. As such, the preceding techn...

  20. Assessing five field sampling methods to monitor Yellowstone National Park's northern ungulate winter range: the advantages and disadvantages of implementing a new sampling protocol

    Treesearch

    Pamela G. Sikkink; Roy Renkin; Geneva Chong; Art Sikkink

    2013-01-01

    The five field sampling methods tested for this study differed in richness and Simpson's Index values calculated from the raw data. How much the methods differed, and which ones were most similar to each other, depended on which diversity measure and which type of data were used for comparisons. When the number of species (richness) was used as a measure of...

  1. MoREK: The learning media to improve students understanding about electrical circuit in informatics

    NASA Astrophysics Data System (ADS)

    Indrianto; Nur Indah Susanti, Meilia; Arianto, Rakhmat

    2018-03-01

    The needs for labor in the world is already increasing especially in Indonesia. According to the World Bank, Indonesia is a country that ranks 9th in the world’s largest economic growth. To meet that needs, Indonesia needs 55 million workers who are experts in the field of electricity. Therefore, it takes a lot of human resources and has been equipped with knowledge and expertise in the field of electricity. To be able to meet these needs, it takes a better method of learning to increase knowledge and expertise in the field of electricity since college, especially in the field of informatics. Prototype of Electrical Module (The MoREK) requires a Prototype method for the Practicum Module to be created as desired. This method is often used in the real world or it could be said Prototype method is part of the product that expresses the logic and physical external interface that is displayed. For data retrieval is used Pre-experimental method where students will be given pre-test and post-test. The Design of Electrical Module has a purpose to improve the students understanding of Electric Circuit Engineering Courses with the creation of The MoREK so that students are more competent to the course and can meet the needs of manpower or Human Resources (SDM) in the field of electricity. By using The Morek, the score of student learning outcomes increased by 7.8% and informatics students who conduct research in the field of electricity increased to 21%.

  2. Realistic Subsurface Anomaly Discrimination Using Electromagnetic Induction and an SVM Classifier

    NASA Astrophysics Data System (ADS)

    Pablo Fernández, Juan; Shubitidze, Fridon; Shamatava, Irma; Barrowes, Benjamin E.; O'Neill, Kevin

    2010-12-01

    The environmental research program of the United States military has set up blind tests for detection and discrimination of unexploded ordnance. One such test consists of measurements taken with the EM-63 sensor at Camp Sibert, AL. We review the performance on the test of a procedure that combines a field-potential (HAP) method to locate targets, the normalized surface magnetic source (NSMS) model to characterize them, and a support vector machine (SVM) to classify them. The HAP method infers location from the scattered magnetic field and its associated scalar potential, the latter reconstructed using equivalent sources. NSMS replaces the target with an enclosing spheroid of equivalent radial magnetization whose integral it uses as a discriminator. SVM generalizes from empirical evidence and can be adapted for multiclass discrimination using a voting system. Our method identifies all potentially dangerous targets correctly and has a false-alarm rate of about 5%.

  3. Assessing the significance of global and local correlations under spatial autocorrelation: a nonparametric approach.

    PubMed

    Viladomat, Júlia; Mazumder, Rahul; McInturff, Alex; McCauley, Douglas J; Hastie, Trevor

    2014-06-01

    We propose a method to test the correlation of two random fields when they are both spatially autocorrelated. In this scenario, the assumption of independence for the pair of observations in the standard test does not hold, and as a result we reject in many cases where there is no effect (the precision of the null distribution is overestimated). Our method recovers the null distribution taking into account the autocorrelation. It uses Monte-Carlo methods, and focuses on permuting, and then smoothing and scaling one of the variables to destroy the correlation with the other, while maintaining at the same time the initial autocorrelation. With this simulation model, any test based on the independence of two (or more) random fields can be constructed. This research was motivated by a project in biodiversity and conservation in the Biology Department at Stanford University. © 2014, The International Biometric Society.

  4. Effects of Notch Misalignment and Tip Radius on Displacement Field in V-Notch Rail Shear Test as Determined by Photogrammetry

    NASA Technical Reports Server (NTRS)

    Hill, Charles S.; Oliveras, Ovidio M.

    2011-01-01

    Evolution of the 3D strain field during ASTM-D-7078 v-notch rail shear tests on 8-ply quasi-isotropic carbon fiber/epoxy laminates was determined by optical photogrammetry using an ARAMIS system. Specimens having non-optimal geometry and minor discrepancies in dimensional tolerances were shown to display non-symmetry and/or stress concentration in the vicinity of the notch relative to a specimen meeting the requirements of the standard, but resulting shear strength and modulus values remained within acceptable bounds of standard deviation. Based on these results, and reported difficulty machining specimens to the required tolerances using available methods, it is suggested that a parametric study combining analytical methods and experiment may provide rationale to increase the tolerances on some specimen dimensions, reducing machining costs, increasing the proportion of acceptable results, and enabling a wider adoption of the test method.

  5. Testing of the 4SM Method in the Gulf of California Suggests Field Data Are not Needed to Derive Satellite Bathymetry

    PubMed Central

    Morel, Yann; Waddington, Andrew; Lopez-Calderon, Jorge; Cadena-Roa, Marco; Blanco-Jarvio, Anidia

    2017-01-01

    Satellite-derived bathymetry methods over coastal areas were developed to deliver basic and useful bathymetry information. However, the process is not straightforward, the main limitation being the need for field data. The Self-calibrated Spectral Supervised Shallow-water Modeler (4SM) method was tested to obtain coastal bathymetry without the use of any field data. Using Landsat-8 multispectral images from 2013 to 2016, a bathymetric time series was produced. Groundtruthed depths and an alternative method, Stumpf’s Band Ratio Algorithm, were used to verify the results. Retrieved (4SM) vs groundtruthed depths scored an average r2 (0.90), and a low error (RMSE = 1.47 m). 4SM also showed, over the whole time series, the same average accuracy of the control method (40%). Advantages, limitations and operability under complex atmosphere and water column conditions, and high and low-albedo bottom processing capabilities of 4SM are discussed. In conclusion, the findings suggest that 4SM is as accurate as the commonly used Stumpf’s method, the only difference being the independence of 4SM from previous field data, and the potential to deliver bottom spectral characteristics for further modeling. 4SM thus represents a significant advance in coastal remote sensing potential to obtain bathymetry and optical properties of the marine bottom. PMID:28973993

  6. Mapping Diffuse Seismicity Using Empirical Matched Field Processing Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, J; Templeton, D C; Harris, D B

    The objective of this project is to detect and locate more microearthquakes using the empirical matched field processing (MFP) method than can be detected using only conventional earthquake detection techniques. We propose that empirical MFP can complement existing catalogs and techniques. We test our method on continuous seismic data collected at the Salton Sea Geothermal Field during November 2009 and January 2010. In the Southern California Earthquake Data Center (SCEDC) earthquake catalog, 619 events were identified in our study area during this time frame and our MFP technique identified 1094 events. Therefore, we believe that the empirical MFP method combinedmore » with conventional methods significantly improves the network detection ability in an efficient matter.« less

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morgan, Nathaniel Ray; Waltz, Jacob I.

    The level set method is commonly used to model dynamically evolving fronts and interfaces. In this work, we present new methods for evolving fronts with a specified velocity field or in the surface normal direction on 3D unstructured tetrahedral meshes with adaptive mesh refinement (AMR). The level set field is located at the nodes of the tetrahedral cells and is evolved using new upwind discretizations of Hamilton–Jacobi equations combined with a Runge–Kutta method for temporal integration. The level set field is periodically reinitialized to a signed distance function using an iterative approach with a new upwind gradient. We discuss themore » details of these level set and reinitialization methods. Results from a range of numerical test problems are presented.« less

  8. METHOD OF CHEMICAL ANALYSIS FOR OIL SHALE WASTES

    EPA Science Inventory

    Several methods of chemical analysis are described for oil shale wastewaters and retort gases. These methods are designed to support the field testing of various pollution control systems. As such, emphasis has been placed on methods which are rapid and sufficiently rugged to per...

  9. Dem Reconstruction Using Light Field and Bidirectional Reflectance Function from Multi-View High Resolution Spatial Images

    NASA Astrophysics Data System (ADS)

    de Vieilleville, F.; Ristorcelli, T.; Delvit, J.-M.

    2016-06-01

    This paper presents a method for dense DSM reconstruction from high resolution, mono sensor, passive imagery, spatial panchromatic image sequence. The interest of our approach is four-fold. Firstly, we extend the core of light field approaches using an explicit BRDF model from the Image Synthesis community which is more realistic than the Lambertian model. The chosen model is the Cook-Torrance BRDF which enables us to model rough surfaces with specular effects using specific material parameters. Secondly, we extend light field approaches for non-pinhole sensors and non-rectilinear motion by using a proper geometric transformation on the image sequence. Thirdly, we produce a 3D volume cost embodying all the tested possible heights and filter it using simple methods such as Volume Cost Filtering or variational optimal methods. We have tested our method on a Pleiades image sequence on various locations with dense urban buildings and report encouraging results with respect to classic multi-label methods such as MIC-MAC, or more recent pipelines such as S2P. Last but not least, our method also produces maps of material parameters on the estimated points, allowing us to simplify building classification or road extraction.

  10. A Multifunctional Interface Method for Coupling Finite Element and Finite Difference Methods: Two-Dimensional Scalar-Field Problems

    NASA Technical Reports Server (NTRS)

    Ransom, Jonathan B.

    2002-01-01

    A multifunctional interface method with capabilities for variable-fidelity modeling and multiple method analysis is presented. The methodology provides an effective capability by which domains with diverse idealizations can be modeled independently to exploit the advantages of one approach over another. The multifunctional method is used to couple independently discretized subdomains, and it is used to couple the finite element and the finite difference methods. The method is based on a weighted residual variational method and is presented for two-dimensional scalar-field problems. A verification test problem and a benchmark application are presented, and the computational implications are discussed.

  11. Soil surface roughness: comparing old and new measuring methods and application in a soil erosion model

    NASA Astrophysics Data System (ADS)

    Thomsen, L. M.; Baartman, J. E. M.; Barneveld, R. J.; Starkloff, T.; Stolte, J.

    2015-04-01

    Quantification of soil roughness, i.e. the irregularities of the soil surface due to soil texture, aggregates, rock fragments and land management, is important as it affects surface storage, infiltration, overland flow, and ultimately sediment detachment and erosion. Roughness has been measured in the field using both contact methods (such as roller chain and pinboard) and sensor methods (such as stereophotogrammetry and terrestrial laser scanning (TLS)). A novel depth-sensing technique, originating in the gaming industry, has recently become available for earth sciences: the Xtion Pro method. Roughness data obtained using various methods are assumed to be similar; this assumption is tested in this study by comparing five different methods to measure roughness in the field on 1 m2 agricultural plots with different management (ploughing, harrowing, forest and direct seeding on stubble) in southern Norway. Subsequently, the values were used as input for the LISEM soil erosion model to test their effect on the simulated hydrograph at catchment scale. Results show that statistically significant differences between the methods were obtained only for the fields with direct seeding on stubble; for the other land management types the methods were in agreement. The spatial resolution of the contact methods was much lower than for the sensor methods (10 000 versus at least 57 000 points per square metre). In terms of costs and ease of use in the field, the Xtion Pro method is promising. Results from the LISEM model indicate that especially the roller chain overestimated the random roughness (RR) values and the model subsequently calculated less surface runoff than measured. In conclusion, the choice of measurement method for roughness data matters and depends on the required accuracy, resolution, mobility in the field and available budget. It is recommended to use only one method within one study.

  12. Soil surface roughness: comparing old and new measuring methods and application in a soil erosion model

    NASA Astrophysics Data System (ADS)

    Thomsen, L. M.; Baartman, J. E. M.; Barneveld, R. J.; Starkloff, T.; Stolte, J.

    2014-11-01

    Quantification of soil roughness, i.e. the irregularities of the soil surface due to soil texture, aggregates, rock fragments and land management, is important as it affects surface storage, infiltration, overland flow and ultimately sediment detachment and erosion. Roughness has been measured in the field using both contact methods, such as roller chain and pinboard, and sensor methods, such as stereophotogrammetry and terrestrial laser scanning (TLS). A novel depth sensing technique, originating in the gaming industry, has recently become available for earth sciences; the Xtion Pro method. Roughness data obtained using various methods are assumed to be similar; this assumption is tested in this study by comparing five different methods to measure roughness in the field on 1 m2 agricultural plots with different management (ploughing, harrowing, forest and direct seeding on stubble) in southern Norway. Subsequently, the values were used as input for the LISEM soil erosion model to test their effect on the simulated hydrograph on catchment scale. Results show that statistically significant differences between the methods were obtained only for the fields with direct drilling on stubble; for the other land management types the methods were in agreement. The spatial resolution of the contact methods was much lower than for the sensor methods (10 000 versus at least 57 000 points per m2 respectively). In terms of costs and ease of handling in the field, the Xtion Pro method is promising. Results from the LISEM model indicate that especially the roller chain underestimated the RR values and the model thereby calculated less surface runoff than measured. In conclusion: the choice of measurement method for roughness data matters and depends on the required accuracy, resolution, mobility in the field and available budget. It is recommended to use only one method within one study.

  13. Analgesic, antibacterial and central nervous system depressant activities of Albizia procera leaves

    PubMed Central

    Khatoon, Mst. Mahfuza; Khatun, Mst. Hajera; Islam, Md. Ekramul; Parvin, Mst. Shahnaj

    2014-01-01

    Objective To ascertain analgesic, antibacterial and central nervous system (CNS) depressant activities of ethyl acetate, dichloromethane and carbon tetrachloride fractions of methanol extract of Albizia procera (A. procera) leaves. Methods Leaves extracts of A. procera were tested for analgesic activity by acetic acid induced and formalin test method in mice. The in vitro antibacterial activity was performed by agar well diffusion method. CNS depressant activity was evaluated by hole cross and open field tests. Results All the extracts at 200 mg/kg exhibited significant (P<0.01) analgesic activity in acetic acid induced and formalin tests method in mice. Analgesic activity of the ethyl acetate fraction was almost same like as standard drug indomethacin in acetic acid induced method. The CNS depressant activity of the extracts at 500 mg/kg was comparable to the positive control diazepam as determined by hole cross and open field test method. The extracts exhibited moderate antimicrobial activity against all the tested microorganisms (Staphylococcus aureus, Bacillus cereus, Pseudomonas aeruginosa, Esherichia coli, Shigella soneii, Shigella boydii) at concentration of 0.8 mg/disc. The measured diameter of zone of inhibition for the extracts was within the range of 7 to 12 mm which was less than the standard kanamycin (16-24 mm). Conclusions It is concluded that all the extracts possess potential analgesic and CNS depressants activity. This study also showed that different fractions of methanol extract could be potential sources of new antimicrobial agents. PMID:25182551

  14. 3D digital image correlation methods for full-field vibration measurement

    NASA Astrophysics Data System (ADS)

    Helfrick, Mark N.; Niezrecki, Christopher; Avitabile, Peter; Schmidt, Timothy

    2011-04-01

    In the area of modal test/analysis/correlation, significant effort has been expended over the past twenty years in order to make reduced models and to expand test data for correlation and eventual updating of the finite element models. This has been restricted by vibration measurements which are traditionally limited to the location of relatively few applied sensors. Advances in computers and digital imaging technology have allowed 3D digital image correlation (DIC) methods to measure the shape and deformation of a vibrating structure. This technique allows for full-field measurement of structural response, thus providing a wealth of simultaneous test data. This paper presents some preliminary results for the test/analysis/correlation of data measured using the DIC approach along with traditional accelerometers and a scanning laser vibrometer for comparison to a finite element model. The results indicate that all three approaches correlated well with the finite element model and provide validation for the DIC approach for full-field vibration measurement. Some of the advantages and limitations of the technique are presented and discussed.

  15. Statistically Assessing Time-Averaged and Paleosecular Variation Field Models Against Paleomagnetic Directional Data Sets. Can Likely non-Zonal Features be Detected in a Robust way ?

    NASA Astrophysics Data System (ADS)

    Hulot, G.; Khokhlov, A.

    2007-12-01

    We recently introduced a method to rigorously test the statistical compatibility of combined time-averaged (TAF) and paleosecular variation (PSV) field models against any lava flow paleomagnetic database (Khokhlov et al., 2001, 2006). Applying this method to test (TAF+PSV) models against synthetic data produced from those shows that the method is very efficient at discriminating models, and very sensitive, provided those data errors are properly taken into account. This prompted us to test a variety of published combined (TAF+PSV) models against a test Bruhnes stable polarity data set extracted from the Quidelleur et al. (1994) data base. Not surprisingly, ignoring data errors leads all models to be rejected. But taking data errors into account leads to the stimulating conclusion that at least one (TAF+PSV) model appears to be compatible with the selected data set, this model being purely axisymmetric. This result shows that in practice also, and with the data bases currently available, the method can discriminate various candidate models and decide which actually best fits a given data set. But it also shows that likely non-zonal signatures of non-homogeneous boundary conditions imposed by the mantle are difficult to identify as statistically robust from paleomagnetic directional data sets. In the present paper, we will discuss the possibility that such signatures could eventually be identified as robust with the help of more recent data sets (such as the one put together under the collaborative "TAFI" effort, see e.g. Johnson et al. abstract #GP21A-0013, AGU Fall Meeting, 2005) or by taking additional information into account (such as the possible coincidence of non-zonal time-averaged field patterns with analogous patterns in the modern field).

  16. A new method of field MRTD test

    NASA Astrophysics Data System (ADS)

    Chen, Zhibin; Song, Yan; Liu, Xianhong; Xiao, Wenjian

    2014-09-01

    MRTD is an important indicator to measure the imaging performance of infrared camera. In the traditional laboratory test, blackbody is used as simulated heat source which is not only expensive and bulky but also difficult to meet field testing requirements of online automatic infrared camera MRTD. To solve this problem, this paper introduces a new detection device for MRTD, which uses LED as a simulation heat source and branded plated zinc sulfide glass carved four-bar target as a simulation target. By using high temperature adaptability cassegrain collimation system, the target is simulated to be distance-infinite so that it can be observed by the human eyes to complete the subjective test, or collected to complete objective measurement by image processing. This method will use LED to replace blackbody. The color temperature of LED is calibrated by thermal imager, thereby, the relation curve between the LED temperature controlling current and the blackbody simulation temperature difference is established, accurately achieved the temperature control of the infrared target. Experimental results show that the accuracy of the device in field testing of thermal imager MRTD can be limited within 0.1K, which greatly reduces the cost to meet the project requirements with a wide application value.

  17. Early detection of glaucoma by means of a novel 3D computer‐automated visual field test

    PubMed Central

    Nazemi, Paul P; Fink, Wolfgang; Sadun, Alfredo A; Francis, Brian; Minckler, Donald

    2007-01-01

    Purpose A recently devised 3D computer‐automated threshold Amsler grid test was used to identify early and distinctive defects in people with suspected glaucoma. Further, the location, shape and depth of these field defects were characterised. Finally, the visual fields were compared with those obtained by standard automated perimetry. Patients and methods Glaucoma suspects were defined as those having elevated intraocular pressure (>21 mm Hg) or cup‐to‐disc ratio of >0.5. 33 patients and 66 eyes with risk factors for glaucoma were examined. 15 patients and 23 eyes with no risk factors were tested as controls. The recently developed 3D computer‐automated threshold Amsler grid test was used. The test exhibits a grid on a computer screen at a preselected greyscale and angular resolution, and allows patients to trace those areas on the grid that are missing in their visual field using a touch screen. The 5‐minute test required that the patients repeatedly outline scotomas on a touch screen with varied displays of contrast while maintaining their gaze on a central fixation marker. A 3D depiction of the visual field defects was then obtained that was further characterised by the location, shape and depth of the scotomas. The exam was repeated three times per eye. The results were compared to Humphrey visual field tests (ie, achromatic standard or SITA standard 30‐2 or 24‐2). Results In this pilot study 79% of the eyes tested in the glaucoma‐suspect group repeatedly demonstrated visual field loss with the 3D perimetry. The 3D depictions of visual field loss associated with these risk factors were all characteristic of or compatible with glaucoma. 71% of the eyes demonstrated arcuate defects or a nasal step. Constricted visual fields were shown in 29% of the eyes. No visual field changes were detected in the control group. Conclusions The 3D computer‐automated threshold Amsler grid test may demonstrate visual field abnormalities characteristic of glaucoma in glaucoma suspects with normal achromatic Humphrey visual field testing. This test may be used as a screening tool for the early detection of glaucoma. PMID:17504855

  18. Mapping gullies, dunes, lava fields, and landslides via surface roughness

    NASA Astrophysics Data System (ADS)

    Korzeniowska, Karolina; Pfeifer, Norbert; Landtwing, Stephan

    2018-01-01

    Gully erosion is a widespread and significant process involved in soil and land degradation. Mapping gullies helps to quantify past, and anticipate future, soil losses. Digital terrain models offer promising data for automatically detecting and mapping gullies especially in vegetated areas, although methods vary widely measures of local terrain roughness are the most varied and debated among these methods. Rarely do studies test the performance of roughness metrics for mapping gullies, limiting their applicability to small training areas. To this end, we systematically explored how local terrain roughness derived from high-resolution Light Detection And Ranging (LiDAR) data can aid in the unsupervised detection of gullies over a large area. We also tested expanding this method for other landforms diagnostic of similarly abrupt land-surface changes, including lava fields, dunes, and landslides, as well as investigating the influence of different roughness thresholds, resolutions of kernels, and input data resolution, and comparing our method with previously published roughness algorithms. Our results show that total curvature is a suitable metric for recognising analysed gullies and lava fields from LiDAR data, with comparable success to that of more sophisticated roughness metrics. Tested dunes or landslides remain difficult to distinguish from the surrounding landscape, partly because they are not easily defined in terms of their topographic signature.

  19. A Novel Field Deployable Point-of-Care Diagnostic Test for Cutaneous Leishmaniasis

    DTIC Science & Technology

    2015-10-01

    include localized cutaneous leishmaniasis (LCL), and destructive nasal and oropharyngeal lesions of mucosal leishmaniasis (ML). LCL in the New World...the high costs, personnel training and need of sophisticated equipment. Therefore, novel methods to detect leishmaniasis at the POC are urgently needed...To date, there is no field-standardized molecular method based on DNA amplification coupled with Lateral Flow reading to detect leishmaniasis

  20. Do Value-Added Methods Level the Playing Field for Teachers? What We Know Series: Value-Added Methods and Applications. Knowledge Brief 2

    ERIC Educational Resources Information Center

    McCaffrey, Daniel F.

    2012-01-01

    Value-added models have caught the interest of policymakers because, unlike using student tests scores for other means of accountability, they purport to "level the playing field." That is, they supposedly reflect only a teacher's effectiveness, not whether she teaches high- or low-income students, for instance, or students in accelerated or…

  1. Service life of fence posts treated by double-diffusion methods

    Treesearch

    Donald C. Markstrom; Lee R. Gjovik

    1999-01-01

    Service-life tests indicate that Engelmann spruce, lodgepole pine, and Rocky Mountain Douglas-fir fence posts treated by double-diffusion methods performed excellently after field exposure of 30 years with no failures. The test site was located in the semiarid Central Plains near Nunn, Colorado. Although Engelmann spruce posts generally defy treatment by other treating...

  2. A novel method for unsteady flow field segmentation based on stochastic similarity of direction

    NASA Astrophysics Data System (ADS)

    Omata, Noriyasu; Shirayama, Susumu

    2018-04-01

    Recent developments in fluid dynamics research have opened up the possibility for the detailed quantitative understanding of unsteady flow fields. However, the visualization techniques currently in use generally provide only qualitative insights. A method for dividing the flow field into physically relevant regions of interest can help researchers quantify unsteady fluid behaviors. Most methods at present compare the trajectories of virtual Lagrangian particles. The time-invariant features of an unsteady flow are also frequently of interest, but the Lagrangian specification only reveals time-variant features. To address these challenges, we propose a novel method for the time-invariant spatial segmentation of an unsteady flow field. This segmentation method does not require Lagrangian particle tracking but instead quantitatively compares the stochastic models of the direction of the flow at each observed point. The proposed method is validated with several clustering tests for 3D flows past a sphere. Results show that the proposed method reveals the time-invariant, physically relevant structures of an unsteady flow.

  3. New approach to estimating variability in visual field data using an image processing technique.

    PubMed Central

    Crabb, D P; Edgar, D F; Fitzke, F W; McNaught, A I; Wynn, H P

    1995-01-01

    AIMS--A new framework for evaluating pointwise sensitivity variation in computerised visual field data is demonstrated. METHODS--A measure of local spatial variability (LSV) is generated using an image processing technique. Fifty five eyes from a sample of normal and glaucomatous subjects, examined on the Humphrey field analyser (HFA), were used to illustrate the method. RESULTS--Significant correlation between LSV and conventional estimates--namely, HFA pattern standard deviation and short term fluctuation, were found. CONCLUSION--LSV is not dependent on normals' reference data or repeated threshold determinations, thus potentially reducing test time. Also, the illustrated pointwise maps of LSV could provide a method for identifying areas of fluctuation commonly found in early glaucomatous field loss. PMID:7703196

  4. Potential, velocity, and density fields from sparse and noisy redshift-distance samples - Method

    NASA Technical Reports Server (NTRS)

    Dekel, Avishai; Bertschinger, Edmund; Faber, Sandra M.

    1990-01-01

    A method for recovering the three-dimensional potential, velocity, and density fields from large-scale redshift-distance samples is described. Galaxies are taken as tracers of the velocity field, not of the mass. The density field and the initial conditions are calculated using an iterative procedure that applies the no-vorticity assumption at an initial time and uses the Zel'dovich approximation to relate initial and final positions of particles on a grid. The method is tested using a cosmological N-body simulation 'observed' at the positions of real galaxies in a redshift-distance sample, taking into account their distance measurement errors. Malmquist bias and other systematic and statistical errors are extensively explored using both analytical techniques and Monte Carlo simulations.

  5. Detecting and enumerating soil-transmitted helminth eggs in soil: New method development and results from field testing in Kenya and Bangladesh.

    PubMed

    Steinbaum, Lauren; Kwong, Laura H; Ercumen, Ayse; Negash, Makeda S; Lovely, Amira J; Njenga, Sammy M; Boehm, Alexandria B; Pickering, Amy J; Nelson, Kara L

    2017-04-01

    Globally, about 1.5 billion people are infected with at least one species of soil-transmitted helminth (STH). Soil is a critical environmental reservoir of STH, yet there is no standard method for detecting STH eggs in soil. We developed a field method for enumerating STH eggs in soil and tested the method in Bangladesh and Kenya. The US Environmental Protection Agency (EPA) method for enumerating Ascaris eggs in biosolids was modified through a series of recovery efficiency experiments; we seeded soil samples with a known number of Ascaris suum eggs and assessed the effect of protocol modifications on egg recovery. We found the use of 1% 7X as a surfactant compared to 0.1% Tween 80 significantly improved recovery efficiency (two-sided t-test, t = 5.03, p = 0.007) while other protocol modifications-including different agitation and flotation methods-did not have a significant impact. Soil texture affected the egg recovery efficiency; sandy samples resulted in higher recovery compared to loamy samples processed using the same method (two-sided t-test, t = 2.56, p = 0.083). We documented a recovery efficiency of 73% for the final improved method using loamy soil in the lab. To field test the improved method, we processed soil samples from 100 households in Bangladesh and 100 households in Kenya from June to November 2015. The prevalence of any STH (Ascaris, Trichuris or hookworm) egg in soil was 78% in Bangladesh and 37% in Kenya. The median concentration of STH eggs in soil in positive samples was 0.59 eggs/g dry soil in Bangladesh and 0.15 eggs/g dry soil in Kenya. The prevalence of STH eggs in soil was significantly higher in Bangladesh than Kenya (chi-square, χ2 = 34.39, p < 0.001) as was the concentration (Mann-Whitney, z = 7.10, p < 0.001). This new method allows for detecting STH eggs in soil in low-resource settings and could be used for standardizing soil STH detection globally.

  6. Prediction of internal and external noise fields for blowdown wind tunnels.

    NASA Technical Reports Server (NTRS)

    Hosier, R. N.; Mayes, W. H.

    1972-01-01

    Empirical methods have been developed to estimate the test section noise levels and the outside noise radiation patterns of blowdown wind tunnels. Included are considerations of noise generation by control valves, burners, turbulent boundary layers, and exhaust jets as appropriate. Sample test section and radiation field noise estimates are presented. The external estimates are noted to be in good agreement with the limited amount of available measurements.

  7. Piezoelectric PVF2 Polymer Films and Devices.

    DTIC Science & Technology

    1981-11-01

    techniques and methods have been increasingly applied in the field of nondestructive testing and evaluation ( NDE ) of mate- rials and structures, and...numerous types of acoustic testing devices have been developed. The importance of acoustics in NDE efforts is expected to increase in the future. Thus...already found commercial applications outside the field of ultra- sonic transducers and NDE . Among the strong piezoelectrics, it has a unique set of

  8. Comparing the field and laboratory emission cell (FLEC) with traditional emissions testing chambers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roache, N.F.; Guo, Z.; Fortmann, R.

    1996-12-31

    A series of tests was designed to evaluate the performance of the field and laboratory emission cell (FLEC) as applied to the testing of emissions from two indoor coating materials, floor wax and latex paint. These tests included validation of the repeatability of the test method, evaluation of the effect of different air velocities on source emissions, and a comparison of FLEC versus small chamber characterization of emissions. The FLEC exhibited good repeatability in characterization of emissions when applied to both sources under identical conditions. Tests with different air velocities showed significant effects on the emissions from latex paint, yetmore » little effect on emissions from the floor wax. Comparisons of data from the FLEC and small chamber show good correlation for measurements involving floor wax, but less favorable results for emissions from latex paint. The procedures and findings are discussed; conclusions are limited and include emphasis on the need for additional study and development of a standard method.« less

  9. [New visual field testing possibilities (a preliminary report)].

    PubMed

    Erichev, V P; Ermolaev, A P; Antonov, A A; Grigoryan, G L; Kosova, D V

    2018-01-01

    There are currently no portable mobile perimeters that allow visual field testing outside ophthalmologist's examination rooms. To develop a mobile perimetry technique based on use of a virtual reality headset (VR). The study involved 26 patients (30 eyes) with II-III stage primary open-angle glaucoma (POAG) with compensated IOP. Perimetry was performed for each patient twice - on Humphrey analyzer (test 30-2, 76 points) and employing similar strategy on a perimeter integrated into VR headset (Total Vision, Russia). Visual field testing was performed with an interval from 1 hour to 3 days. The results were comparatively analyzed. Patients tolerated the examination well. Comparative analysis of preliminary perimetry results obtained with both methods showed high degree of identity, so the results were concluded to be comparable. By visually isolating the wearer, VR headset achieves elimination of distractions and stable light conditions for visual field testing. The headset-perimeter is compact, mobile, easily transportable, can be used in the work of visiting medical teams and for examination at home.

  10. Practical estimates of field-saturated hydraulic conductivity of bedrock outcrops using a modified bottomless bucket method

    USGS Publications Warehouse

    Mirus, Benjamin B.; Perkins, Kim S.

    2012-01-01

    The bottomless bucket (BB) approach (Nimmo et al., 2009a) is a cost-effective method for rapidly characterizing field-saturated hydraulic conductivity Kfs of soils and alluvial deposits. This practical approach is of particular value for quantifying infiltration rates in remote areas with limited accessibility. A similar approach for bedrock outcrops is also of great value for improving quantitative understanding of infiltration and recharge in rugged terrain. We develop a simple modification to the BB method for application to bedrock outcrops, which uses a non-toxic, quick-drying silicone gel to seal the BB to the bedrock. These modifications to the field method require only minor changes to the analytical solution for calculating Kfs on soils. We investigate the reproducibility of the method with laboratory experiments on a previously studied calcarenite rock and conduct a sensitivity analysis to quantify uncertainty in our predictions. We apply the BB method on both bedrock and soil for sites on Pahute Mesa, which is located in a remote area of the Nevada National Security Site. The bedrock BB tests may require monitoring over several hours to days, depending on infiltration rates, which necessitates a cover to prevent evaporative losses. Our field and laboratory results compare well to Kfs values inferred from independent reports, which suggests the modified BB method can provide useful estimates and facilitate simple hypothesis testing. The ease with which the bedrock BB method can be deployed should facilitate more rapid in-situ data collection than is possible with alternative methods for quantitative characterization of infiltration into bedrock.

  11. Field-based video pre-test counseling, oral testing, and telephonic post-test counseling: implementation of an HIV field testing package among high-risk Indian men.

    PubMed

    Snyder, Hannah; Yeldandi, Vijay V; Prem Kumar, G; Liao, Chuanhong; Lakshmi, Vemu; Gandham, Sabitha R; Muppudi, Uma; Oruganti, Ganesh; Schneider, John A

    2012-08-01

    In India, men who have sex with men (MSM) and truck drivers are high-risk groups that often do not access HIV testing due to stigma and high mobility. This study evaluated a field testing package (FTP) that identified HIV positive participants through video pre-test counseling, OraQuick oral fluid HIV testing, and telephonic post-test counseling and then connected them to government facilities. A total of 598 MSM and truck drivers participated in the FTP and completed surveys covering sociodemographics, HIV testing history, risk behaviors, and opinions on the FTP. MSM and truck drivers equally preferred video counseling, although MSM who had been previously tested preferred traditional methods. Nearly all participants preferred oral testing. Rates of counseling completion and linkage to government centers were low, with one-third of newly identified positives completing follow-up. With increased public-private coordination, this FTP could identify many hard-to-reach preliminary positive individuals and connect them to government testing and care.

  12. Improved definition of crustal anomalies for Magsat data

    NASA Technical Reports Server (NTRS)

    1981-01-01

    A scheme was developed for separating the portions of the magnetic field measured by the Magsat 1 satellite that arise from internal and external sources. To test this method, a set of sample coefficients were used to compute the field values along a simulated satellite orbit. This data was then used to try to recover the original coefficients. Matrix inversion and recursive least squares methods were used to solve for the input coefficients. The accuracy of the two methods are compared.

  13. Nanoscale methods for single-molecule electrochemistry.

    PubMed

    Mathwig, Klaus; Aartsma, Thijs J; Canters, Gerard W; Lemay, Serge G

    2014-01-01

    The development of experiments capable of probing individual molecules has led to major breakthroughs in fields ranging from molecular electronics to biophysics, allowing direct tests of knowledge derived from macroscopic measurements and enabling new assays that probe population heterogeneities and internal molecular dynamics. Although still somewhat in their infancy, such methods are also being developed for probing molecular systems in solution using electrochemical transduction mechanisms. Here we outline the present status of this emerging field, concentrating in particular on optical methods, metal-molecule-metal junctions, and electrochemical nanofluidic devices.

  14. Acoustically Induced Vibration of Structures: Reverberant Vs. Direct Acoustic Testing

    NASA Technical Reports Server (NTRS)

    Kolaini, Ali R.; O'Connell, Michael R.; Tsoi, Wan B.

    2009-01-01

    Large reverberant chambers have been used for several decades in the aerospace industry to test larger structures such as solar arrays and reflectors to qualify and to detect faults in the design and fabrication of spacecraft and satellites. In the past decade some companies have begun using direct near field acoustic testing, employing speakers, for qualifying larger structures. A limited test data set obtained from recent acoustic tests of the same hardware exposed to both direct and reverberant acoustic field testing has indicated some differences in the resulting structural responses. In reverberant acoustic testing, higher vibration responses were observed at lower frequencies when compared with the direct acoustic testing. In the case of direct near field acoustic testing higher vibration responses appeared to occur at higher frequencies as well. In reverberant chamber testing and direct acoustic testing, standing acoustic modes of the reverberant chamber or the speakers and spacecraft parallel surfaces can strongly couple with the fundamental structural modes of the test hardware. In this paper data from recent acoustic testing of flight hardware, that yielded evidence of acoustic standing wave coupling with structural responses, are discussed in some detail. Convincing evidence of the acoustic standing wave/structural coupling phenomenon will be discussed, citing observations from acoustic testing of a simple aluminum plate. The implications of such acoustic coupling to testing of sensitive flight hardware will be discussed. The results discussed in this paper reveal issues with over or under testing of flight hardware that could pose unanticipated structural and flight qualification issues. Therefore, it is of paramount importance to understand the structural modal coupling with standing acoustic waves that has been observed in both methods of acoustic testing. This study will assist the community to choose an appropriate testing method and test setup in the planning stages.

  15. Comparison of chemiluminescence methods for analysis of hydrogen peroxide and hydroxyl radicals

    NASA Astrophysics Data System (ADS)

    Pehrman, R.; Amme, M.; Cachoir, C.

    2006-01-01

    Assessment of alpha radiolysis influence on the chemistry of geologically disposed spent fuel demands analytical methods for radiolytic product determination at trace levels. Several chemiluminescence methods for the detection of radiolytic oxidants hydrogen peroxide and hydroxyl radicals are tested. Two of hydrogen peroxide methods use luminol, catalyzed by either μ-peroxidase or hemin, one uses 10-methyl-9-(p-formylphenyl)-acridinium carboxylate trifluoromethanesulfonate and one potassium periodate. All recipes are tested as batch systems in basic conditions. For hydroxyl radical detection luminophores selected are 3-hydroxyphthalic hydrazide and rutin. Both methods are tested as batch systems. The results are compared and the applicability of the methods for near-field dissolution studies is discussed.

  16. Reactive transport studies at the Raymond Field Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Freifeld, B.; Karasaki, K.; Solbau, R.

    1995-12-01

    To ensure the safety of a nuclear waste repository, an understanding of the transport of radionuclides from the repository nearfield to the biosphere is necessary. At the Raymond Field Site, in Raymond, California, tracer tests are being conducted to test characterization methods for fractured media and to evaluate the equipment and tracers that will be used for Yucca Mountain`s fracture characterization. Recent tracer tests at Raymond have used reactive cations to demonstrate transport with sorption. A convective-dispersive model was used to simulate a two-well recirculating test with reasonable results. However, when the same model was used to simulate a radiallymore » convergent tracer test, the model poorly predicted the actual test data.« less

  17. Field evaluation of a rapid, visually-read colloidal dye immunofiltration assay for Schistosoma japonicum for screening in areas of low transmission.

    PubMed Central

    Xiao, Xiang; Wang, Tianping; Ye, Hongzhuan; Qiang, Guangxiang; Wei, Haiming; Tian, Zhigang

    2005-01-01

    OBJECTIVE: To determine the validity of a recently developed rapid test--a colloidal dye immunofiltration assay (CDIFA)--used by health workers in field settings to identify villagers infected with Schistosoma japonicum. METHODS: Health workers in the field used CDIFA to test samples from 1553 villagers in two areas of low endemicity and an area where S. japonicum was not endemic in Anhui, China. All the samples were then tested in the laboratory by laboratory staff using a standard parasitological method (Kato-Katz), an indirect haemagglutination assay (IHA), and CDIFA. The results of CDIFA performed by health workers were compared with those obtained by Kato-Katz and IHA. FINDINGS: Concordance between the results of CDIFA performed in field settings and in the laboratory was high (kappa index, 0.95; 95% confidence interval, 0.93-0.97). When Kato-Katz was used as the reference test, the overall sensitivity and specificity of CDIFA were 98.5% and 83.6%, respectively in the two villages in areas of low endemicity, while the specificity was 99.8% in the nonendemic village. Compared with IHA, the overall specificity and sensitivity of CDIFA were greater than 99% and 96%, respectively. With the combination of Kato-Katz and IHA as the reference standard, CDIFA had a sensitivity of 95.8% and a specificity of 99.5%, and an accuracy of 98.6% in the two areas of low endemicity. CONCLUSION: CDIFA is a specific, sensitive, and reliable test that can be used for rapid screening for schistosomiasis by health workers in field settings. PMID:16175827

  18. The multi-line slope method for measuring the effective magnetic field of cool stars: an application to the solar-like cycle of ɛ Eri

    NASA Astrophysics Data System (ADS)

    Scalia, C.; Leone, F.; Gangi, M.; Giarrusso, M.; Stift, M. J.

    2017-12-01

    One method for the determination of integrated longitudinal stellar fields from low-resolution spectra is the so-called slope method, which is based on the regression of the Stokes V signal against the first derivative of Stokes I. Here we investigate the possibility of extending this technique to measure the magnetic fields of cool stars from high-resolution spectra. For this purpose we developed a multi-line modification to the slope method, called the multi-line slope method. We tested this technique by analysing synthetic spectra computed with the COSSAM code and real observations obtained with the high-resolution spectropolarimeters Narval, HARPSpol and the Catania Astrophysical Observatory Spectropolarimeter (CAOS). We show that the multi-line slope method is a fast alternative to the least squares deconvolution technique for the measurement of the effective magnetic fields of cool stars. Using a Fourier transform on the effective magnetic field variations of the star ε Eri, we find that the long-term periodicity of the field corresponds to the 2.95-yr period of the stellar dynamo, revealed by the variation of the activity index.

  19. Evaluation and refinement of a field-portable drinking water toxicity sensor utilizing electric cell-substrate impedance sensing and a fluidic biochip.

    PubMed

    Widder, Mark W; Brennan, Linda M; Hanft, Elizabeth A; Schrock, Mary E; James, Ryan R; van der Schalie, William H

    2015-07-01

    The US Army's need for a reliable and field-portable drinking water toxicity sensor was the catalyst for the development and evaluation of an electric cell-substrate impedance sensing (ECIS) device. Water testing technologies currently available to soldiers in the field are analyte-specific and have limited capabilities to detect broad-based water toxicity. The ECIS sensor described here uses rainbow trout gill epithelial cells seeded on fluidic biochips to measure changes in impedance for the detection of possible chemical contamination of drinking water supplies. Chemicals selected for testing were chosen as representatives of a broad spectrum of toxic industrial compounds. Results of a US Environmental Protection Agency (USEPA)-sponsored evaluation of the field portable device were similar to previously published US Army testing results of a laboratory-based version of the same technology. Twelve of the 18 chemicals tested following USEPA Technology Testing and Evaluation Program procedures were detected by the ECIS sensor within 1 h at USEPA-derived human lethal concentrations. To simplify field-testing methods further, elimination of a procedural step that acclimated cells to serum-free media streamlined the test process with only a slight loss of chemical sensitivity. For field use, the ECIS sensor will be used in conjunction with an enzyme-based sensor that is responsive to carbamate and organophosphorus pesticides. Copyright © 2014 John Wiley & Sons, Ltd.

  20. Temporally diffeomorphic cardiac motion estimation from three-dimensional echocardiography by minimization of intensity consistency error.

    PubMed

    Zhang, Zhijun; Ashraf, Muhammad; Sahn, David J; Song, Xubo

    2014-05-01

    Quantitative analysis of cardiac motion is important for evaluation of heart function. Three dimensional (3D) echocardiography is among the most frequently used imaging modalities for motion estimation because it is convenient, real-time, low-cost, and nonionizing. However, motion estimation from 3D echocardiographic sequences is still a challenging problem due to low image quality and image corruption by noise and artifacts. The authors have developed a temporally diffeomorphic motion estimation approach in which the velocity field instead of the displacement field was optimized. The optimal velocity field optimizes a novel similarity function, which we call the intensity consistency error, defined as multiple consecutive frames evolving to each time point. The optimization problem is solved by using the steepest descent method. Experiments with simulated datasets, images of anex vivo rabbit phantom, images of in vivo open-chest pig hearts, and healthy human images were used to validate the authors' method. Simulated and real cardiac sequences tests showed that results in the authors' method are more accurate than other competing temporal diffeomorphic methods. Tests with sonomicrometry showed that the tracked crystal positions have good agreement with ground truth and the authors' method has higher accuracy than the temporal diffeomorphic free-form deformation (TDFFD) method. Validation with an open-access human cardiac dataset showed that the authors' method has smaller feature tracking errors than both TDFFD and frame-to-frame methods. The authors proposed a diffeomorphic motion estimation method with temporal smoothness by constraining the velocity field to have maximum local intensity consistency within multiple consecutive frames. The estimated motion using the authors' method has good temporal consistency and is more accurate than other temporally diffeomorphic motion estimation methods.

  1. Adaptations of the Saker-Solomons test: simple, reliable colorimetric field assays for chloroquine and its metabolites in urine.

    PubMed

    Mount, D L; Nahlen, B L; Patchen, L C; Churchill, F C

    1989-01-01

    Two field-adapted colorimetric methods for measuring the antimalarial drug chloroquine in urine are described. Both are modifications of the method of Saker and Solomons for screening urine for phencyclidine and other drugs of abuse, using the colour reagent tetrabromophenolphthalein ethyl ester. One method is semiquantitative, detecting the presence of chloroquine (Cq) and its metabolites in urine with a 1 microgram/ml detection limit; it is more sensitive and reliable than the commonly used Dill-Glazko method and is as easy to apply in the field. The second method uses a hand-held, battery-operated filter photometer to quantify Cq and its metabolites with a 2 microgram/ml detection limit and a linear range up to 8 micrograms/ml. The first method was validated in the field using a published quantitative colorimetric method and samples from a malaria study in Nigeria. The second method was validated in the laboratory against high-performance liquid chromatographic results on paired samples from the Nigerian study. Both methods may be used in remote locations where malaria is endemic and no electricity is available.

  2. Identification and modification of dominant noise sources in diesel engines

    NASA Astrophysics Data System (ADS)

    Hayward, Michael D.

    Determination of dominant noise sources in diesel engines is an integral step in the creation of quiet engines, but is a process which can involve an extensive series of expensive, time-consuming fired and motored tests. The goal of this research is to determine dominant noise source characteristics of a diesel engine in the near and far-fields with data from fewer tests than is currently required. Pre-conditioning and use of numerically robust methods to solve a set of cross-spectral density equations results in accurate calculation of the transfer paths between the near- and far-field measurement points. Application of singular value decomposition to an input cross-spectral matrix determines the spectral characteristics of a set of independent virtual sources, that, when scaled and added, result in the input cross spectral matrix. Each virtual source power spectral density is a singular value resulting from the decomposition performed over a range of frequencies. The complex relationship between virtual and physical sources is estimated through determination of virtual source contributions to each input measurement power spectral density. The method is made more user-friendly through use of a percentage contribution color plotting technique, where different normalizations can be used to help determine the presence of sources and the strengths of their contributions. Convolution of input measurements with the estimated path impulse responses results in a set of far-field components, to which the same singular value contribution plotting technique can be applied, thus allowing dominant noise source characteristics in the far-field to also be examined. Application of the methods presented results in determination of the spectral characteristics of dominant noise sources both in the near- and far-fields from one fired test, which significantly reduces the need for extensive fired and motored testing. Finally, it is shown that the far-field noise time history of a physically altered engine can be simulated through modification of singular values and recalculation of transfer paths between input and output measurements of previously recorded data.

  3. The visual detection of driving while intoxicated : field test of visual cues and detection methods

    DOT National Transportation Integrated Search

    1980-04-01

    A Drunk Driver Detection Guide was developed and tested at a sample of 10 law enforcement agencies at locations throughout the United States. The test was designed to provide both longitudinal and cross-sectional analyses of several measures likely t...

  4. Comparative assessment of pressure field reconstructions from particle image velocimetry measurements and Lagrangian particle tracking

    NASA Astrophysics Data System (ADS)

    van Gent, P. L.; Michaelis, D.; van Oudheusden, B. W.; Weiss, P.-É.; de Kat, R.; Laskari, A.; Jeon, Y. J.; David, L.; Schanz, D.; Huhn, F.; Gesemann, S.; Novara, M.; McPhaden, C.; Neeteson, N. J.; Rival, D. E.; Schneiders, J. F. G.; Schrijer, F. F. J.

    2017-04-01

    A test case for pressure field reconstruction from particle image velocimetry (PIV) and Lagrangian particle tracking (LPT) has been developed by constructing a simulated experiment from a zonal detached eddy simulation for an axisymmetric base flow at Mach 0.7. The test case comprises sequences of four subsequent particle images (representing multi-pulse data) as well as continuous time-resolved data which can realistically only be obtained for low-speed flows. Particle images were processed using tomographic PIV processing as well as the LPT algorithm `Shake-The-Box' (STB). Multiple pressure field reconstruction techniques have subsequently been applied to the PIV results (Eulerian approach, iterative least-square pseudo-tracking, Taylor's hypothesis approach, and instantaneous Vortex-in-Cell) and LPT results (FlowFit, Vortex-in-Cell-plus, Voronoi-based pressure evaluation, and iterative least-square pseudo-tracking). All methods were able to reconstruct the main features of the instantaneous pressure fields, including methods that reconstruct pressure from a single PIV velocity snapshot. Highly accurate reconstructed pressure fields could be obtained using LPT approaches in combination with more advanced techniques. In general, the use of longer series of time-resolved input data, when available, allows more accurate pressure field reconstruction. Noise in the input data typically reduces the accuracy of the reconstructed pressure fields, but none of the techniques proved to be critically sensitive to the amount of noise added in the present test case.

  5. Detecting and enumerating soil-transmitted helminth eggs in soil: New method development and results from field testing in Kenya and Bangladesh

    PubMed Central

    Kwong, Laura H.; Ercumen, Ayse; Negash, Makeda S.; Lovely, Amira J.; Njenga, Sammy M.; Boehm, Alexandria B.; Pickering, Amy J.; Nelson, Kara L.

    2017-01-01

    Globally, about 1.5 billion people are infected with at least one species of soil-transmitted helminth (STH). Soil is a critical environmental reservoir of STH, yet there is no standard method for detecting STH eggs in soil. We developed a field method for enumerating STH eggs in soil and tested the method in Bangladesh and Kenya. The US Environmental Protection Agency (EPA) method for enumerating Ascaris eggs in biosolids was modified through a series of recovery efficiency experiments; we seeded soil samples with a known number of Ascaris suum eggs and assessed the effect of protocol modifications on egg recovery. We found the use of 1% 7X as a surfactant compared to 0.1% Tween 80 significantly improved recovery efficiency (two-sided t-test, t = 5.03, p = 0.007) while other protocol modifications—including different agitation and flotation methods—did not have a significant impact. Soil texture affected the egg recovery efficiency; sandy samples resulted in higher recovery compared to loamy samples processed using the same method (two-sided t-test, t = 2.56, p = 0.083). We documented a recovery efficiency of 73% for the final improved method using loamy soil in the lab. To field test the improved method, we processed soil samples from 100 households in Bangladesh and 100 households in Kenya from June to November 2015. The prevalence of any STH (Ascaris, Trichuris or hookworm) egg in soil was 78% in Bangladesh and 37% in Kenya. The median concentration of STH eggs in soil in positive samples was 0.59 eggs/g dry soil in Bangladesh and 0.15 eggs/g dry soil in Kenya. The prevalence of STH eggs in soil was significantly higher in Bangladesh than Kenya (chi-square, χ2 = 34.39, p < 0.001) as was the concentration (Mann-Whitney, z = 7.10, p < 0.001). This new method allows for detecting STH eggs in soil in low-resource settings and could be used for standardizing soil STH detection globally. PMID:28379956

  6. 3D level set methods for evolving fronts on tetrahedral meshes with adaptive mesh refinement

    DOE PAGES

    Morgan, Nathaniel Ray; Waltz, Jacob I.

    2017-03-02

    The level set method is commonly used to model dynamically evolving fronts and interfaces. In this work, we present new methods for evolving fronts with a specified velocity field or in the surface normal direction on 3D unstructured tetrahedral meshes with adaptive mesh refinement (AMR). The level set field is located at the nodes of the tetrahedral cells and is evolved using new upwind discretizations of Hamilton–Jacobi equations combined with a Runge–Kutta method for temporal integration. The level set field is periodically reinitialized to a signed distance function using an iterative approach with a new upwind gradient. We discuss themore » details of these level set and reinitialization methods. Results from a range of numerical test problems are presented.« less

  7. High-Altitude Hydration System

    NASA Technical Reports Server (NTRS)

    Parazynski, Scott E.; Orndoff, Evelyne; Bue, Grant C.; Schaefbauer, Mark E.; Urban, Kase

    2010-01-01

    Three methods are being developed for keeping water from freezing during high-altitude climbs so that mountaineers can remain hydrated. Three strategies have been developed. At the time of this reporting two needed to be tested in the field and one was conceptual. The first method is Passive Thermal Control Using Aerogels. This involves mounting the fluid reservoir of the climber s canteen to an inner layer of clothing for better heat retention. For the field test, bottles were mounted to the inner fleece layer of clothing, and then aerogel insulation was placed on the outside of the bottle, and circumferentially around the drink straw. When climbers need to drink, they can pull up the insulated straw from underneath the down suit, take a sip, and then put it back into the relative warmth of the suit. For the field test, a data logger assessed the temperatures of the water reservoir, as well as near the tip of the drink straw. The second method is Passive Thermal Control with Copper-Shielded Drink Straw and Aerogels, also mounted to inner layers of clothing for better heat retention. Braided wire emanates from the inside of the fleece jacket layer, and continues up and around the drink straw in order to use body heat to keep the system-critical drink straw warm enough to keep water in the liquid state. For the field test, a data logger will be used to compare this with the above concept. The third, and still conceptual, method is Active Thermal Control with Microcontroller. If the above methods do not work, microcontrollers and tape heaters have been identified that could keep the drink straw warm even under extremely cold conditions. Power requirements are not yet determined because the thermal environment inside the down suit relative to the external environment has not been established. A data logger will be used to track both the external and internal temperatures of the suit on a summit day.

  8. Pattern recognition of satellite cloud imagery for improved weather prediction

    NASA Technical Reports Server (NTRS)

    Gautier, Catherine; Somerville, Richard C. J.; Volfson, Leonid B.

    1986-01-01

    The major accomplishment was the successful development of a method for extracting time derivative information from geostationary meteorological satellite imagery. This research is a proof-of-concept study which demonstrates the feasibility of using pattern recognition techniques and a statistical cloud classification method to estimate time rate of change of large-scale meteorological fields from remote sensing data. The cloud classification methodology is based on typical shape function analysis of parameter sets characterizing the cloud fields. The three specific technical objectives, all of which were successfully achieved, are as follows: develop and test a cloud classification technique based on pattern recognition methods, suitable for the analysis of visible and infrared geostationary satellite VISSR imagery; develop and test a methodology for intercomparing successive images using the cloud classification technique, so as to obtain estimates of the time rate of change of meteorological fields; and implement this technique in a testbed system incorporating an interactive graphics terminal to determine the feasibility of extracting time derivative information suitable for comparison with numerical weather prediction products.

  9. Standing wave performance test of IDT-SAW transducer prepared by silk-screen printing

    NASA Astrophysics Data System (ADS)

    Wang, Ziping; Jiang, Zhengxuan; Chen, Liangbin; Li, Yefei; Li, Meixia; Wang, Shaohan

    2018-05-01

    With the advantages of high performance and low loss, interdigital surface acoustic wave (IDT-SAW) transducers are widely used in the fields of nondestructive testing, communication and broadcasting. The production, performance and application of surface acoustic wave (SAW) actuators has become a research hotspot. Based on the basic principle of SAW, an IDT-SAW transducer is designed and fabricated using silk-screen printing in this work. The experiment results show that in terms of SAW performance, the fabricated IDT-SAW transducer can generate standing wave fields comparable to those generated using traditional fabrication methods. The resonant frequency response of the IDT-SAW transducer and SAW attenuation coefficient were obtained by experiments. It has provided a method to test the transducer sensing performance by using fabricated IDT-SAW transducer.

  10. A Spatial-frequency Method for Analyzing Antenna-to-Probe Interactions in Near-field Antenna Measurements.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brock, Billy C.

    The measurement of the radiation characteristics of an antenna on a near-field range requires that the antenna under test be located very close to the near-field probe. Although the direct coupling is utilized for characterizing the near field, this close proximity also presents the opportunity for significant undesired interactions (for example, reflections) to occur between the antenna and the near-field probe. When uncompensated, these additional interactions will introduce error into the measurement, increasing the uncertainty in the final gain pattern obtained through the near-field-to-far-field transformation. Quantifying this gain-uncertainty contribution requires quantifying the various additional interactions. A method incorporating spatial-frequency analysismore » is described which allows the dominant interaction contributions to be easily identified and quantified. In addition to identifying the additional antenna-to-probe interactions, the method also allows identification and quantification of interactions with other nearby objects within the measurement room. Because the method is a spatial-frequency method, wide-bandwidth data is not required, and it can be applied even when data is available at only a single temporal frequency. This feature ensures that the method can be applied to narrow-band antennas, where a similar time-domain analysis would not be possible. - 3 - - 4 -« less

  11. Power Hardware-in-the-Loop Evaluation of PV Inverter Grid Support on Hawaiian Electric Feeders: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelson, Austin; Prabakar, Kumaraguru; Nagarajan, Adarsh

    As more grid-connected photovoltaic (PV) inverters become compliant with evolving interconnections requirements, there is increased interest from utilities in understanding how to best deploy advanced grid-support functions (GSF) in the field. One efficient and cost-effective method to examine such deployment options is to leverage power hardware-in-the-loop (PHIL) testing methods. Two Hawaiian Electric feeder models were converted to real-time models in the OPAL-RT real-time digital testing platform, and integrated with models of GSF capable PV inverters that were modeled from characterization test data. The integrated model was subsequently used in PHIL testing to evaluate the effects of different fixed power factormore » and volt-watt control settings on voltage regulation of the selected feeders. The results of this study were provided as inputs for field deployment and technical interconnection requirements for grid-connected PV inverters on the Hawaiian Islands.« less

  12. A robust, finite element model for hydrostatic surface water flows

    USGS Publications Warehouse

    Walters, R.A.; Casulli, V.

    1998-01-01

    A finite element scheme is introduced for the 2-dimensional shallow water equations using semi-implicit methods in time. A semi-Lagrangian method is used to approximate the effects of advection. A wave equation is formed at the discrete level such that the equations decouple into an equation for surface elevation and a momentum equation for the horizontal velocity. The convergence rates and relative computational efficiency are examined with the use of three test cases representing various degrees of difficulty. A test with a polar-quadrant grid investigates the response to local grid-scale forcing and the presence of spurious modes, a channel test case establishes convergence rates, and a field-scale test case examines problems with highly irregular grids.A finite element scheme is introduced for the 2-dimensional shallow water equations using semi-implicit methods in time. A semi-Lagrangian method is used to approximate the effects of advection. A wave equation is formed at the discrete level such that the equations decouple into an equation for surface elevation and a momentum equation for the horizontal velocity. The convergence rates and relative computational efficiency are examined with the use of three test cases representing various degrees of difficulty. A test with a polar-quadrant grid investigates the response to local grid-scale forcing and the presence of spurious modes, a channel test case establishes convergence rates, and a field-scale test case examines problems with highly irregular grids.

  13. A method for the estimate of the wall diffusion for non-axisymmetric fields using rotating external fields

    NASA Astrophysics Data System (ADS)

    Frassinetti, L.; Olofsson, K. E. J.; Fridström, R.; Setiadi, A. C.; Brunsell, P. R.; Volpe, F. A.; Drake, J.

    2013-08-01

    A new method for the estimate of the wall diffusion time of non-axisymmetric fields is developed. The method based on rotating external fields and on the measurement of the wall frequency response is developed and tested in EXTRAP T2R. The method allows the experimental estimate of the wall diffusion time for each Fourier harmonic and the estimate of the wall diffusion toroidal asymmetries. The method intrinsically considers the effects of three-dimensional structures and of the shell gaps. Far from the gaps, experimental results are in good agreement with the diffusion time estimated with a simple cylindrical model that assumes a homogeneous wall. The method is also applied with non-standard configurations of the coil array, in order to mimic tokamak-relevant settings with a partial wall coverage and active coils of large toroidal extent. The comparison with the full coverage results shows good agreement if the effects of the relevant sidebands are considered.

  14. Comparative field permeability measurement of permeable pavements using ASTM C1701 and NCAT permeameter methods.

    PubMed

    Li, Hui; Kayhanian, Masoud; Harvey, John T

    2013-03-30

    Fully permeable pavement is gradually gaining support as an alternative best management practice (BMP) for stormwater runoff management. As the use of these pavements increases, a definitive test method is needed to measure hydraulic performance and to evaluate clogging, both for performance studies and for assessment of permeability for construction quality assurance and maintenance needs assessment. Two of the most commonly used permeability measurement tests for porous asphalt and pervious concrete are the National Center for Asphalt Technology (NCAT) permeameter and ASTM C1701, respectively. This study was undertaken to compare measured values for both methods in the field on a variety of permeable pavements used in current practice. The field measurements were performed using six experimental section designs with different permeable pavement surface types including pervious concrete, porous asphalt and permeable interlocking concrete pavers. Multiple measurements were performed at five locations on each pavement test section. The results showed that: (i) silicone gel is a superior sealing material to prevent water leakage compared with conventional plumbing putty; (ii) both methods (NCAT and ASTM) can effectively be used to measure the permeability of all pavement types and the surface material type will not impact the measurement precision; (iii) the permeability values measured with the ASTM method were 50-90% (75% on average) lower than those measured with the NCAT method; (iv) the larger permeameter cylinder diameter used in the ASTM method improved the reliability and reduced the variability of the measured permeability. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. On the Ground or in the Air? A Methodological Experiment on Crop Residue Cover Measurement in Ethiopia

    NASA Astrophysics Data System (ADS)

    Kosmowski, Frédéric; Stevenson, James; Campbell, Jeff; Ambel, Alemayehu; Haile Tsegay, Asmelash

    2017-10-01

    Maintaining permanent coverage of the soil using crop residues is an important and commonly recommended practice in conservation agriculture. Measuring this practice is an essential step in improving knowledge about the adoption and impact of conservation agriculture. Different data collection methods can be implemented to capture the field level crop residue coverage for a given plot, each with its own implication on survey budget, implementation speed and respondent and interviewer burden. In this paper, six alternative methods of crop residue coverage measurement are tested among the same sample of rural households in Ethiopia. The relative accuracy of these methods are compared against a benchmark, the line-transect method. The alternative methods compared against the benchmark include: (i) interviewee (respondent) estimation; (ii) enumerator estimation visiting the field; (iii) interviewee with visual-aid without visiting the field; (iv) enumerator with visual-aid visiting the field; (v) field picture collected with a drone and analyzed with image-processing methods and (vi) satellite picture of the field analyzed with remote sensing methods. Results of the methodological experiment show that survey-based methods tend to underestimate field residue cover. When quantitative data on cover are needed, the best estimates are provided by visual-aid protocols. For categorical analysis (i.e., >30% cover or not), visual-aid protocols and remote sensing methods perform equally well. Among survey-based methods, the strongest correlates of measurement errors are total farm size, field size, distance, and slope. Results deliver a ranking of measurement options that can inform survey practitioners and researchers.

  16. On the Ground or in the Air? A Methodological Experiment on Crop Residue Cover Measurement in Ethiopia.

    PubMed

    Kosmowski, Frédéric; Stevenson, James; Campbell, Jeff; Ambel, Alemayehu; Haile Tsegay, Asmelash

    2017-10-01

    Maintaining permanent coverage of the soil using crop residues is an important and commonly recommended practice in conservation agriculture. Measuring this practice is an essential step in improving knowledge about the adoption and impact of conservation agriculture. Different data collection methods can be implemented to capture the field level crop residue coverage for a given plot, each with its own implication on survey budget, implementation speed and respondent and interviewer burden. In this paper, six alternative methods of crop residue coverage measurement are tested among the same sample of rural households in Ethiopia. The relative accuracy of these methods are compared against a benchmark, the line-transect method. The alternative methods compared against the benchmark include: (i) interviewee (respondent) estimation; (ii) enumerator estimation visiting the field; (iii) interviewee with visual-aid without visiting the field; (iv) enumerator with visual-aid visiting the field; (v) field picture collected with a drone and analyzed with image-processing methods and (vi) satellite picture of the field analyzed with remote sensing methods. Results of the methodological experiment show that survey-based methods tend to underestimate field residue cover. When quantitative data on cover are needed, the best estimates are provided by visual-aid protocols. For categorical analysis (i.e., >30% cover or not), visual-aid protocols and remote sensing methods perform equally well. Among survey-based methods, the strongest correlates of measurement errors are total farm size, field size, distance, and slope. Results deliver a ranking of measurement options that can inform survey practitioners and researchers.

  17. High performance field emission of silicon carbide nanowires and their applications in flexible field emission displays

    NASA Astrophysics Data System (ADS)

    Cui, Yunkang; Chen, Jing; Di, Yunsong; Zhang, Xiaobing; Lei, Wei

    2017-12-01

    In this paper, a facile method to fabricate the flexible field emission devices (FEDs) based on SiC nanostructure emitters by a thermal evaporation method has been demonstrated. The composition characteristics of SiC nanowires was characterized by X-ray diffraction (XRD), selected area electron diffraction (SAED) and energy dispersive X-ray spectrometer (EDX), while the morphology was revealed by field emission scanning electron microscopy (SEM) and high resolution transmission electron microscopy (HRTEM). The results showed that the SiC nanowires grew along the [111] direction with the diameter of ˜110 nm and length of˜30 μm. The flexible FEDs have been fabricated by transferring and screen-printing the SiC nanowires onto the flexible substrates exhibited excellent field emission properties, such as the low turn-on field (˜0.95 V/μm) and threshold field (˜3.26 V/μm), and the high field enhancement factor (β=4670). It is worth noting the current density degradation can be controlled lower than 2% per hour during the stability tests. In addition, the flexible FEDs based on SiC nanowire emitters exhibit uniform bright emission modes under bending test conditions. As a result, this strategy is very useful for its potential application in the commercial flexible FEDs.

  18. A Pilot Study of a Picture- and Audio-Assisted Self-Interviewing Method (PIASI) for the Study of Sensitive Questions on HIV in the Field

    ERIC Educational Resources Information Center

    Aarnio, Pauliina; Kulmala, Teija

    2016-01-01

    Self-interview methods such as audio computer-assisted self-interviewing (ACASI) are used to improve the accuracy of interview data on sensitive topics in large trials. Small field studies on sensitive topics would benefit from methodological alternatives. In a study on male involvement in antenatal HIV testing in a largely illiterate population…

  19. Research for the Fluid Field of the Centrifugal Compressor Impeller in Accelerating Startup

    NASA Astrophysics Data System (ADS)

    Li, Xiaozhu; Chen, Gang; Zhu, Changyun; Qin, Guoliang

    2013-03-01

    In order to study the flow field in the impeller in the accelerating start-up process of centrifugal compressor, the 3-D and 1-D transient accelerated flow governing equations along streamline in the impeller of the centrifugal compressor are derived in detail, the assumption of pressure gradient distribution is presented, and the solving method for 1-D transient accelerating flow field is given based on the assumption. The solving method is achieved by programming and the computing result is obtained. It is obtained by comparison that the computing method is met with the test result. So the feasibility and effectiveness for solving accelerating start-up problem of centrifugal compressor by the solving method in this paper is proven.

  20. Methods for the field evaluation of quantitative G6PD diagnostics: a review.

    PubMed

    Ley, Benedikt; Bancone, Germana; von Seidlein, Lorenz; Thriemer, Kamala; Richards, Jack S; Domingo, Gonzalo J; Price, Ric N

    2017-09-11

    Individuals with glucose-6-phosphate dehydrogenase (G6PD) deficiency are at risk of severe haemolysis following the administration of 8-aminoquinoline compounds. Primaquine is the only widely available 8-aminoquinoline for the radical cure of Plasmodium vivax. Tafenoquine is under development with the potential to simplify treatment regimens, but point-of-care (PoC) tests will be needed to provide quantitative measurement of G6PD activity prior to its administration. There is currently a lack of appropriate G6PD PoC tests, but a number of new tests are in development and are likely to enter the market in the coming years. As these are implemented, they will need to be validated in field studies. This article outlines the technical details for the field evaluation of novel quantitative G6PD diagnostics such as sample handling, reference testing and statistical analysis. Field evaluation is based on the comparison of paired samples, including one sample tested by the new assay at point of care and one sample tested by the gold-standard reference method, UV spectrophotometry in an established laboratory. Samples can be collected as capillary or venous blood; the existing literature suggests that potential differences in capillary or venous blood are unlikely to affect results substantially. The collection and storage of samples is critical to ensure preservation of enzyme activity, it is recommended that samples are stored at 4 °C and testing occurs within 4 days of collection. Test results can be visually presented as scatter plot, Bland-Altman plot, and a histogram of the G6PD activity distribution of the study population. Calculating the adjusted male median allows categorizing results according to G6PD activity to calculate standard performance indicators and to perform receiver operating characteristic (ROC) analysis.

  1. Combined target factor analysis and Bayesian soft-classification of interference-contaminated samples: forensic fire debris analysis.

    PubMed

    Williams, Mary R; Sigman, Michael E; Lewis, Jennifer; Pitan, Kelly McHugh

    2012-10-10

    A bayesian soft classification method combined with target factor analysis (TFA) is described and tested for the analysis of fire debris data. The method relies on analysis of the average mass spectrum across the chromatographic profile (i.e., the total ion spectrum, TIS) from multiple samples taken from a single fire scene. A library of TIS from reference ignitable liquids with assigned ASTM classification is used as the target factors in TFA. The class-conditional distributions of correlations between the target and predicted factors for each ASTM class are represented by kernel functions and analyzed by bayesian decision theory. The soft classification approach assists in assessing the probability that ignitable liquid residue from a specific ASTM E1618 class, is present in a set of samples from a single fire scene, even in the presence of unspecified background contributions from pyrolysis products. The method is demonstrated with sample data sets and then tested on laboratory-scale burn data and large-scale field test burns. The overall performance achieved in laboratory and field test of the method is approximately 80% correct classification of fire debris samples. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  2. Development testing of large volume water sprays for warm fog dispersal

    NASA Technical Reports Server (NTRS)

    Keller, V. W.; Anderson, B. J.; Burns, R. A.; Lala, G. G.; Meyer, M. B.; Beard, K. V.

    1986-01-01

    A new brute-force method of warm fog dispersal is described. The method uses large volume recycled water sprays to create curtains of falling drops through which the fog is processed by the ambient wind and spray induced air flow. Fog droplets are removed by coalescence/rainout. The efficiency of the technique depends upon the drop size spectra in the spray, the height to which the spray can be projected, the efficiency with which fog laden air is processed through the curtain of spray, and the rate at which new fog may be formed due to temperature differences between the air and spray water. Results of a field test program, implemented to develop the data base necessary to assess the proposed method, are presented. Analytical calculations based upon the field test results indicate that this proposed method of warm fog dispersal is feasible. Even more convincingly, the technique was successfully demonstrated in the one natural fog event which occurred during the test program. Energy requirements for this technique are an order of magnitude less than those to operate a thermokinetic system. An important side benefit is the considerable emergency fire extinguishing capability it provides along the runway.

  3. Methods to Prove 20+ Year Life of CPV Products (in less than 20 Years)

    NASA Astrophysics Data System (ADS)

    Bowman, John; Spencer, Mark

    2011-12-01

    Due to the long term life expectations of photovoltaic products and the short duration of most introduced CPV technologies, it is critical for CPV companies to carefully construct field trials to prove product life. Because of the complicated geometric, thermal, and spectral characteristics of CPV systems, conducting very precise power output measurements reproducibly over many months is very difficult. Robust normalization methods specific to the exact optical system and PV cell type must be developed. Once the performance over a specific duration, e.g. one year, is established, then some justification is required to extrapolate to future performance. Comparisons to accelerated test results provide this justification. SolFocus has been conducting field trials of the SF-1100S CPV system for over two years. These field trials consist of controlled populations of SF-1100P modules, operating in grid-tied systems, which have been repeatedly measured at the individual module level over the duration of the trials. In this paper, field data will be presented along with normalization methodology and statistical methods for determining power degradation slope distributions for populations of individual modules. These results will be correlated with accelerated field tests which have been ongoing for 1.5 years and are estimated to be equivalent to 10 to 15 years of non-accelerated operation.

  4. Experiments of multichannel least-square methods for sound field reproduction inside aircraft mock-up: Objective evaluations

    NASA Astrophysics Data System (ADS)

    Gauthier, P.-A.; Camier, C.; Lebel, F.-A.; Pasco, Y.; Berry, A.; Langlois, J.; Verron, C.; Guastavino, C.

    2016-08-01

    Sound environment reproduction of various flight conditions in aircraft mock-ups is a valuable tool for the study, prediction, demonstration and jury testing of interior aircraft sound quality and annoyance. To provide a faithful reproduced sound environment, time, frequency and spatial characteristics should be preserved. Physical sound field reproduction methods for spatial sound reproduction are mandatory to immerse the listener's body in the proper sound fields so that localization cues are recreated at the listener's ears. Vehicle mock-ups pose specific problems for sound field reproduction. Confined spaces, needs for invisible sound sources and very specific acoustical environment make the use of open-loop sound field reproduction technologies such as wave field synthesis (based on free-field models of monopole sources) not ideal. In this paper, experiments in an aircraft mock-up with multichannel least-square methods and equalization are reported. The novelty is the actual implementation of sound field reproduction with 3180 transfer paths and trim panel reproduction sources in laboratory conditions with a synthetic target sound field. The paper presents objective evaluations of reproduced sound fields using various metrics as well as sound field extrapolation and sound field characterization.

  5. Validity of flowmeter data in heterogeneous alluvial aquifers

    NASA Astrophysics Data System (ADS)

    Bianchi, Marco

    2017-04-01

    Numerical simulations are performed to evaluate the impact of medium-scale sedimentary architecture and small-scale heterogeneity on the validity of the borehole flowmeter test, a widely used method for measuring hydraulic conductivity (K) at the scale required for detailed groundwater flow and solute transport simulations. Reference data from synthetic K fields representing the range of structures and small-scale heterogeneity typically observed in alluvial systems are compared with estimated values from numerical simulations of flowmeter tests. Systematic errors inherent in the flowmeter K estimates are significant when the reference K field structure deviates from the hypothetical perfectly stratified conceptual model at the basis of the interpretation method of flowmeter tests. Because of these errors, the true variability of the K field is underestimated and the distributions of the reference K data and log-transformed spatial increments are also misconstrued. The presented numerical analysis shows that the validity of flowmeter based K data depends on measureable parameters defining the architecture of the hydrofacies, the conductivity contrasts between the hydrofacies and the sub-facies-scale K variability. A preliminary geological characterization is therefore essential for evaluating the optimal approach for accurate K field characterization.

  6. Automated x-ray/light field congruence using the LINAC EPID panel.

    PubMed

    Polak, Wojciech; O'Doherty, Jim; Jones, Matt

    2013-03-01

    X-ray/light field alignment is a test described in many guidelines for the routine quality control of clinical linear accelerators (LINAC). Currently, the gold standard method for measuring alignment is through utilization of radiographic film. However, many modern LINACs are equipped with an electronic portal imaging device (EPID) that may be used to perform this test and thus subsequently reducing overall cost, processing, and analysis time, removing operator dependency and the requirement to sustain the departmental film processor. This work describes a novel method of utilizing the EPID together with a custom inhouse designed jig and automatic image processing software allowing measurement of the light field size, x-ray field size, and congruence between them. The authors present results of testing the method for aS1000 and aS500 Varian EPID detectors for six LINACs at a range of energies (6, 10, and 15 MV) in comparison with the results obtained from the use of radiographic film. Reproducibility of the software in fully automatic operation under a range of operating conditions for a single image showed a congruence of 0.01 cm with a coefficient of variation of 0. Slight variation in congruence repeatability was noted through semiautomatic processing by four independent operators due to manual marking of positions on the jig. Testing of the methodology using the automatic method shows a high precision of 0.02 mm compared to a maximum of 0.06 mm determined by film processing. Intraindividual examination of operator measurements of congruence was shown to vary as much as 0.75 mm. Similar congruence measurements of 0.02 mm were also determined for a lower resolution EPID (aS500 model), after rescaling of the image to the aS1000 image size. The designed methodology was proven to be time efficient, cost effective, and at least as accurate as using the gold standard radiographic film. Additionally, congruence testing can be easily performed for all four cardinal gantry angles which can be difficult when using radiographic film. Therefore, the authors propose it can be used as an alternative to the radiographic film method allowing decommissioning of the film processor.

  7. Testing of Photomultiplier Tubes in a Magnetic Field

    NASA Astrophysics Data System (ADS)

    Waldron, Zachary; A1 Collaboration

    2016-09-01

    The A1 collaboration at MAMI in Mainz, Germany has designed a neutron detector that can be used in experiments to measure the electric form factor of the neutron. They will measure elastic scattering from the neutron, using the polarized electron beam from MAMI at A1's experimental hall. The detector will be composed of two walls of staggered scintillator bars which will be read out by photomultiplier tubes (PMT), connected to both ends of each scintillator via light guides. The experiment requires a magnetic field with strength of 1 Tesla, 2m away from the first scintillator wall. The resulting fringe field is sufficient to disrupt the PMTs, despite the addition of Mu Metal shielding. The effects of the fringe field on these PMTs was tested to optimize the amplification of the PMTs. A Helmholtz Coil was designed to generate a controlled magnetic field with equivalent strength to the field that the PMTs will encounter. The PMTs were read out using a multi-channel analyzer, were tested at various angles relative to the magnetic field in order to determine the optimal orientation to minimize signal disruption. Tests were also performed to determine: the neutron detector response to cosmic radiation; and the best method for measuring a magnetic field's strength in two dimensions. National Science Foundation Grant No. IIA-1358175.

  8. Fast solver for large scale eddy current non-destructive evaluation problems

    NASA Astrophysics Data System (ADS)

    Lei, Naiguang

    Eddy current testing plays a very important role in non-destructive evaluations of conducting test samples. Based on Faraday's law, an alternating magnetic field source generates induced currents, called eddy currents, in an electrically conducting test specimen. The eddy currents generate induced magnetic fields that oppose the direction of the inducing magnetic field in accordance with Lenz's law. In the presence of discontinuities in material property or defects in the test specimen, the induced eddy current paths are perturbed and the associated magnetic fields can be detected by coils or magnetic field sensors, such as Hall elements or magneto-resistance sensors. Due to the complexity of the test specimen and the inspection environments, the availability of theoretical simulation models is extremely valuable for studying the basic field/flaw interactions in order to obtain a fuller understanding of non-destructive testing phenomena. Theoretical models of the forward problem are also useful for training and validation of automated defect detection systems. Theoretical models generate defect signatures that are expensive to replicate experimentally. In general, modelling methods can be classified into two categories: analytical and numerical. Although analytical approaches offer closed form solution, it is generally not possible to obtain largely due to the complex sample and defect geometries, especially in three-dimensional space. Numerical modelling has become popular with advances in computer technology and computational methods. However, due to the huge time consumption in the case of large scale problems, accelerations/fast solvers are needed to enhance numerical models. This dissertation describes a numerical simulation model for eddy current problems using finite element analysis. Validation of the accuracy of this model is demonstrated via comparison with experimental measurements of steam generator tube wall defects. These simulations generating two-dimension raster scan data typically takes one to two days on a dedicated eight-core PC. A novel direct integral solver for eddy current problems and GPU-based implementation is also investigated in this research to reduce the computational time.

  9. Evaluation of Methods for In-Situ Calibration of Field-Deployable Microphone Phased Arrays

    NASA Technical Reports Server (NTRS)

    Humphreys, William M.; Lockard, David P.; Khorrami, Mehdi R.; Culliton, William G.; McSwain, Robert G.

    2017-01-01

    Current field-deployable microphone phased arrays for aeroacoustic flight testing require the placement of hundreds of individual sensors over a large area. Depending on the duration of the test campaign, the microphones may be required to stay deployed at the testing site for weeks or even months. This presents a challenge in regards to tracking the response (i.e., sensitivity) of the individual sensors as a function of time in order to evaluate the health of the array. To address this challenge, two different methods for in-situ tracking of microphone responses are described. The first relies on the use of an aerial sound source attached as a payload on a hovering small Unmanned Aerial System (sUAS) vehicle. The second relies on the use of individually excited ground-based sound sources strategically placed throughout the array pattern. Testing of the two methods was performed in microphone array deployments conducted at Fort A.P. Hill in 2015 and at Edwards Air Force Base in 2016. The results indicate that the drift in individual sensor responses can be tracked reasonably well using both methods. Thus, in-situ response tracking methods are useful as a diagnostic tool for monitoring the health of a phased array during long duration deployments.

  10. Development of Scatterometer-Derived Surface Pressures

    NASA Astrophysics Data System (ADS)

    Hilburn, K. A.; Bourassa, M. A.; O'Brien, J. J.

    2001-12-01

    SeaWinds scatterometer-derived wind fields can be used to estimate surface pressure fields. The method to be used has been developed and tested with Seasat-A and NSCAT wind measurements. The method involves blending two dynamically consistent values of vorticity. Geostrophic relative vorticity is calculated from an initial guess surface pressure field (AVN analysis in this case). Relative vorticity is calculated from SeaWinds winds, adjusted to a geostrophic value, and then blended with the initial guess. An objective method applied minimizes the differences between the initial guess field and scatterometer field, subject to regularization. The long-term goal of this project is to derive research-quality pressure fields from the SeaWinds winds for the Southern Ocean from the Antarctic ice sheet to 30 deg S. The intermediate goal of this report involves generation of pressure fields over the northern hemisphere for testing purposes. Specifically, two issues need to be addressed. First, the most appropriate initial guess field will be determined: the pure AVN analysis or the previously assimilated pressure field. The independent comparison data to be used in answering this question will involve data near land, ship data, and ice data that were not included in the AVN analysis. Second, the smallest number of pressure observations required to anchor the assimilated field will be determined. This study will use Neumann (derivative) boundary conditions on the region of interest. Such boundary conditions only determine the solution to within a constant that must be determined by a number of anchoring points. The smallness of the number of anchoring points will demonstrate the viability of the general use of the scatterometer as a barometer over the oceans.

  11. Leaching Test Relationships, Laboratory-to-Field Comparisons and Recommendations for Leaching Evaluation using the Leaching Environmental Assessment Framework (LEAF)

    EPA Science Inventory

    This report presents examples of the relationships between the results of laboratory leaching tests, as defined by the Leaching Environmental Assessment Framework (LEAF) or analogous international test methods, and leaching of constituents from a broad range of materials under di...

  12. 40 CFR Figure E-1 to Subpart E of... - Designation Testing Checklist

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) Field Sampling Procedure (§ 53.30, .31, .34) Design Specification Tests Filter (L-6) Range of... Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II... Process or of Documented Evidence: Performance, Design or Application Spec. Corresponding to Sections of...

  13. 40 CFR Figure E-1 to Subpart E of... - Designation Testing Checklist

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) Field Sampling Procedure (§ 53.30, .31, .34) Design Specification Tests Filter (L-6) Range of... Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II... Process or of Documented Evidence: Performance, Design or Application Spec. Corresponding to Sections of...

  14. 40 CFR Figure E-1 to Subpart E of... - Designation Testing Checklist

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Field Sampling Procedure (§ 53.30, .31, .34) Design Specification Tests Filter ( L-6) Range of... Testing Physical (Design) and Performance Characteristics of Reference Methods and Class I and Class II... Process or of Documented Evidence: Performance, Design or Application Spec. Corresponding to Sections of...

  15. Cross-Language Mediation in Foreign Language Teaching and Testing

    ERIC Educational Resources Information Center

    Stathopoulou, Maria

    2015-01-01

    This book contributes to the growing field of foreign language teaching and testing by shedding light on mediation between languages. Stathopoulou offers an empirically-grounded definition of mediation as a form of translanguaging and offers tools and methods for further research in multilingual testing. The book explores what cross-language…

  16. Natural pixel decomposition for computational tomographic reconstruction from interferometric projection: algorithms and comparison

    NASA Astrophysics Data System (ADS)

    Cha, Don J.; Cha, Soyoung S.

    1995-09-01

    A computational tomographic technique, termed the variable grid method (VGM), has been developed for improving interferometric reconstruction of flow fields under ill-posed data conditions of restricted scanning and incomplete projection. The technique is based on natural pixel decomposition, that is, division of a field into variable grid elements. The performances of two algorithms, that is, original and revised versions, are compared to investigate the effects of the data redundancy criteria and seed element forming schemes. Tests of the VGMs are conducted through computer simulation of experiments and reconstruction of fields with a limited view angel of 90 degree(s). The temperature fields at two horizontal sections of a thermal plume of two interacting isothermal cubes, produced by a finite numerical code, are analyzed as test fields. The computer simulation demonstrates the superiority of the revised VGM to either the conventional fixed grid method or the original VGM. Both the maximum and average reconstruction errors are reduced appreciably. The reconstruction shows substantial improvement in the regions with dense scanning by probing rays. These regions are usually of interest in engineering applications.

  17. Blade Testing Trends (Presentation)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Desmond, M.

    2014-08-01

    As an invited guest speaker, Michael Desmond presented on NREL's NWTC structural testing methods and capabilities at the 2014 Sandia Blade Workshop held on August 26-28, 2014 in Albuquerque, NM. Although dynamometer and field testing capabilities were mentioned, the presentation focused primarily on wind turbine blade testing, including descriptions and capabilities for accredited certification testing, historical methodology and technology deployment, and current research and development activities.

  18. Insecticidal effects of deltamethrin in laboratory and field populations of Culicoides species: how effective are host-contact reduction methods in India?

    PubMed

    De Keyser, Rien; Cassidy, Clare; Laban, Swathi; Gopal, Prakash; Pickett, John A; Reddy, Yarabolu K; Prasad, Minakshi; Prasad, Gaya; Chirukandoth, Sreekumar; Senthilven, Kandasamy; Carpenter, Simon; Logan, James G

    2017-01-31

    Bluetongue virus (BTV) is transmitted by Culicoides biting midges and causes bluetongue (BT), a clinical disease observed primarily in sheep. BT has a detrimental effect on subsistence farmers in India, where hyperendemic outbreaks impact on smallholdings in the southern states of the country. In this study, we establish a reliable method for testing the toxic effects of deltamethrin on Culicoides and then compare deltamethrin with traditional control methods used by farmers in India. Effects of deltamethrin were initially tested using a colonised strain of Culicoides nubeculosus Meigen and a modified World Health Organisation exposure assay. This method was then applied to field populations of Culicoides spp. in India. The field population of C. oxystoma in India had a greater LC 50 (0.012 ± 0.009%) for deltamethrin than laboratory-reared C.nubeculosus (0.0013 ± 0.0002%). Exposure of C. nubeculosus to deltamethrin at higher ambient temperatures resulted in greater rates of knockdown but a lower mortality rate at 24 h post-exposure. Behavioural assays with C. nubeculosus in WHO tubes provided evidence for contact irritancy and spatial repellence caused by deltamethrin. The field experiments in India, however, provided no evidence for repellent or toxic effects of deltamethrin. Traditional methods such as the application of neem oil and burning of neem leaves also provided no protection. Our study demonstrates that field-collected Culicoides in India are less susceptible to deltamethrin exposure than laboratory-bred C. nubeculosus and traditional methods of insect control do not provide protection to sheep. These low levels of susceptibility to deltamethrin have not been recorded before in field populations of Culicoides and suggest resistance to synthetic pyrethrioids. Alternative insect control methods, in addition to vaccination, may be needed to protect Indian livestock from BTV transmission.

  19. Embankment Criteria and Performance Report: Adobe Dam Gila River Basin, New River and Phoenix City Streams, Arizona.

    DTIC Science & Technology

    1983-06-01

    Field Control Results 18 - Record Test Results 18 GRAVEL DRAIN MATERIAL, 19 FILTER MATERIAL, 20 ABUTMET INFILL MATERIAL- 20 X. EMBANKMENT ANALYSIS 21 XI...Thirty-three in-situ density tests were conducted in the near surface embankment foundation materials by the sand displacement method . An additional...seven densities were obtained from undisturbed samples by the bulk density method . The results of density tests in the foundation are shown on plate

  20. Current status of antifungal susceptibility testing methods.

    PubMed

    Arikan, Sevtap

    2007-11-01

    Antifungal susceptibility testing is a very dynamic field of medical mycology. Standardization of in vitro susceptibility tests by the Clinical and Laboratory Standards Institute (CLSI) and the European Committee for Antimicrobial Susceptibility Testing (EUCAST), and current availability of reference methods constituted the major remarkable steps in the field. Based on the established minimum inhibitory concentration (MIC) breakpoints, it is now possible to determine the susceptibilities of Candida strains to fluconazole, itraconazole, voriconazole, and flucytosine. Moreover, utility of fluconazole antifungal susceptibility tests as an adjunct in optimizing treatment of candidiasis has now been validated. While the MIC breakpoints and clinical significance of susceptibility testing for the remaining fungi and antifungal drugs remain yet unclear, modifications of the available methods as well as other methodologies are being intensively studied to overcome the present drawbacks and limitations. Among the other methods under investigation are Etest, colorimetric microdilution, agar dilution, determination of fungicidal activity, flow cytometry, and ergosterol quantitation. Etest offers the advantage of practical application and favorable agreement rates with the reference methods that are frequently above acceptable limits. However, MIC breakpoints for Etest remain to be evaluated and established. Development of commercially available, standardized colorimetric panels that are based on CLSI method parameters has added more to the antifungal susceptibility testing armamentarium. Flow cytometry, on the other hand, appears to offer rapid susceptibility testing but requires specified equipment and further evaluation for reproducibility and standardization. Ergosterol quantitation is another novel approach, which appears potentially beneficial particularly in discrimination of azole-resistant isolates from heavy trailers. The method is yet investigational and requires to be further studied. Developments in methodology and applications of antifungal susceptibility testing will hopefully provide enhanced utility in clinical guidance of antifungal therapy. However, and particularly in immunosuppressed host, in vitro susceptibility is and will remain only one of several factors that influence clinical outcome.

  1. Non-invasive continuous imaging of drug release from soy-based skin equivalent using wide-field interferometry

    NASA Astrophysics Data System (ADS)

    Gabai, Haniel; Baranes-Zeevi, Maya; Zilberman, Meital; Shaked, Natan T.

    2013-04-01

    We propose an off-axis interferometric imaging system as a simple and unique modality for continuous, non-contact and non-invasive wide-field imaging and characterization of drug release from its polymeric device used in biomedicine. In contrast to the current gold-standard methods in this field, usually based on chromatographic and spectroscopic techniques, our method requires no user intervention during the experiment, and only one test-tube is prepared. We experimentally demonstrate imaging and characterization of drug release from soy-based protein matrix, used as skin equivalent for wound dressing with controlled anesthetic, Bupivacaine drug release. Our preliminary results demonstrate the high potential of our method as a simple and low-cost modality for wide-field imaging and characterization of drug release from drug delivery devices.

  2. Hydraulic characterization of aquifers by thermal response testing

    NASA Astrophysics Data System (ADS)

    Wagner, Valentin; Blum, Philipp; Bayer, Peter

    2014-05-01

    Temperature as a major physical quantity of the subsurface, and naturally occurring thermal anomalies are recognized as promising passive tracers to characterize the subsurface. Accelerated by the increasing popularity of geothermal energy, also active thermal field experiments have gained interest in hydrogeology. Such experiments involve artificial local ground heating or cooling. Among these, the thermal response test (TRT) is one of the most established field investigation techniques in shallow geothermal applications. It is a common method to investigate important subsurface heat transport parameters to design sustainable ground-source heat pump (GSHP) systems. During the test, the borehole heat exchanger (BHE) is heated up with a defined amount of energy by circulating a heat carrier fluid. By comparing temperature change between BHE inlet and outlet, the ability of the BHE to transfer heat or cold to the ambient ground is assessed. However, standard interpretation does not provide any insight into the governing processes of in-situ heat transfer. We utilize a groundwater advection sensitive TRT evaluation approach based on the analytical moving line source equation. It is shown that the TRT as a classical geothermal field test can also be used as a hydrogeological field test. Our approach benefits from the fact that thermal properties, such as thermal conductivity, of natural aquifers typically are much less variable than hydraulic properties, such as hydraulic conductivity. It is possible to determine a relatively small hydraulic conductivity range with our TRT evaluation approach, given realistic ranges for thermal conductivity, volumetric heat capacity, thermal dispersivity and thermal borehole resistance. The method is successfully tested on a large-scale geothermal laboratory experiment (9 m × 6 m × 4.5 m) and with a commercially performed TRT in the field scale. The laboratory experiment consists of a layered artificial aquifer, which is penetrated by a short BHE. This BHE is used to record a groundwater influenced TRT dataset. The performed field TRT is measured at a BHE located in the Upper Rhine Valley in South-West Germany, which penetrates a 68 m thick gravel aquifer with significant horizontal groundwater flow. At both sites, the derived hydraulic conductivity ranges obtained from TRT evaluation are shown to be within the ranges obtained from classical hydrogeological methods such as sieve analysis and pumping tests. This confirms that the temperature signal recorded during thermal response tests can be employed as a thermal tracer and that the evaluation of such a signal can be applied to estimate aquifer hydraulic conductivities.

  3. Full-field fabric stress mapping by micro Raman spectroscopy in a yarn push-out test.

    PubMed

    Lei, Z K; Qin, F Y; Fang, Q C; Bai, R X; Qiu, W; Chen, X

    2018-02-01

    The full-field stress distribution of a two-dimensional plain fabric was mapped using micro Raman spectroscopy (MRS) through a novel yarn push-out test, simulating a quasi-static projectile impact on the fabric. The stress-strain relationship for a single yarn was established using a digital image correlation method in a single-yarn tensile test. The relationship between Raman peak shift and aramid Kevlar 49 yarn stress was established using MRS in a single-yarn tensile test. An out-of-plane loading test was conducted on an aramid Kevlar 49 plain fabric, and the yarn stress was measured using MRS. From the full-field fabric stress distribution, it can be observed that there is a cross-shaped distribution of high yarn stress; this result would be helpful in further studies on load transfer on a fabric during a projectile impact.

  4. Development of the EM tomography system by the vertical electromagnetic profiling (VEMP) method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miura, Y.; Osato, K.; Takasugi, S.

    1995-12-31

    As a part of the {open_quotes}Deep-Seated Geothermal Resources Survey{close_quotes} project being undertaken by the NEDO, the Vertical ElectroMagnetic Profiling (VEMP) method is being developed to accurately obtain deep resistivity structure. The VEMP method acquires multi-frequency three-component magnetic field data in an open hole well using controlled sources (loop sources or grounded-wire sources) emitted at the surface. Numerical simulation using EM3D demonstrated that phase data of the VEMP method is very sensitive to resistivity structure and the phase data will also indicate presence of deep anomalies. Forward modelling was also used to determine required transmitter moments for various grounded-wire and loopmore » sources for a field test using the WD-1 well in the Kakkonda geothermal area. Field logging of the well was carried out in May 1994 and the processed field data matches well the simulated data.« less

  5. Reproducing Quantum Probability Distributions at the Speed of Classical Dynamics: A New Approach for Developing Force-Field Functors.

    PubMed

    Sundar, Vikram; Gelbwaser-Klimovsky, David; Aspuru-Guzik, Alán

    2018-04-05

    Modeling nuclear quantum effects is required for accurate molecular dynamics (MD) simulations of molecules. The community has paid special attention to water and other biomolecules that show hydrogen bonding. Standard methods of modeling nuclear quantum effects like Ring Polymer Molecular Dynamics (RPMD) are computationally costlier than running classical trajectories. A force-field functor (FFF) is an alternative method that computes an effective force field that replicates quantum properties of the original force field. In this work, we propose an efficient method of computing FFF using the Wigner-Kirkwood expansion. As a test case, we calculate a range of thermodynamic properties of Neon, obtaining the same level of accuracy as RPMD, but with the shorter runtime of classical simulations. By modifying existing MD programs, the proposed method could be used in the future to increase the efficiency and accuracy of MD simulations involving water and proteins.

  6. Structural behavior of the Bitter plate tf magnet for the Zephyr ignition test reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bobrov, E.S.; Becker, H.

    1981-01-01

    This paper discusses methods and results of the computer structural analysis of the Bitter plate toroidal field magnet design for the ZEPHYR Ignition Test Reactor. The magnet provides a field of 7.06 T at the center of the bore which is 1.76 m from the major toroidal axis. The ignited plasma is located at a major radius of 1.36 m where the magnetic field is 9.11 T. The plasma is moved to this final position following compression in the major radius. The horizontal bore of the magnet is 1.8 m.

  7. Individual Characteristics and Unit Performance: A Review of Research and Methods

    DTIC Science & Technology

    1985-02-01

    behavioral segments, improves performance. Simu- lation exercises , especially those employing new high-technology devices, provide surrogate...high-technology training simulation exercise MOB Military Occupational Specialty ORTT Operational Readiness Training Test-a field test REALTRAIN A...REAListic TRAINing simulation exercise SAM Surface-to-Air Missile SAT Scholastic Aptitude Test SQT Skill Qualification Test-an Army performance meas

  8. Scalar field dark energy with a minimal coupling in a spherically symmetric background

    NASA Astrophysics Data System (ADS)

    Matsumoto, Jiro

    Dark energy models and modified gravity theories have been actively studied and the behaviors in the solar system have been also carefully investigated in a part of the models. However, the isotropic solutions of the field equations in the simple models of dark energy, e.g. quintessence model without matter coupling, have not been well investigated. One of the reason would be the nonlinearity of the field equations. In this paper, a method to evaluate the solution of the field equations is constructed, and it is shown that there is a model that can easily pass the solar system tests, whereas, there is also a model that is constrained from the solar system tests.

  9. Information engineering for molecular diagnostics.

    PubMed Central

    Sorace, J. M.; Ritondo, M.; Canfield, K.

    1994-01-01

    Clinical laboratories are beginning to apply the recent advances in molecular biology to the testing of patient samples. The emerging field of Molecular Diagnostics will require a new Molecular Diagnostics Laboratory Information System which handles the data types, samples and test methods found in this field. The system must be very flexible in regards to supporting ad-hoc queries. The requirements which are shaping the developments in this field are reviewed and a data model developed. Several queries which demonstrate the data models ability to support the information needs of this area have been developed and run. These results demonstrate the ability of the purposed data model to meet the current and projected needs of this rapidly expanding field. PMID:7949937

  10. A New Technique for Precision Photometry Using Alt/Az Telescopes

    NASA Astrophysics Data System (ADS)

    Kirkaptrick, Colin; Stacey, Piper; Swift, Jonathan

    2018-06-01

    We present and test a new method for flat field calibration of images obtained on telescopes with altitude-azimuth (Alt-Az) mounts. Telescopes using Alt-Az mounts typically employ a field “de-rotator” to account for changing parallactic angles of targets observed across the sky, or for long exposures of a single target. This “de-rotation” results in a changing orientation of the telescope optics with respect to the camera. This, in turn, can result in a flat field that is a function of camera orientation due to, for example, vignetting. In order to account for these changes we develop and test a new flat field technique using the observations of known transiting exoplanets.

  11. Vegetation classification of Coffea on Hawaii Island using WorldView-2 satellite imagery

    NASA Astrophysics Data System (ADS)

    Gaertner, Julie; Genovese, Vanessa Brooks; Potter, Christopher; Sewake, Kelvin; Manoukis, Nicholas C.

    2017-10-01

    Coffee is an important crop in tropical regions of the world; about 125 million people depend on coffee agriculture for their livelihoods. Understanding the spatial extent of coffee fields is useful for management and control of coffee pests such as Hypothenemus hampei and other pests that use coffee fruit as a host for immature stages such as the Mediterranean fruit fly, for economic planning, and for following changes in coffee agroecosystems over time. We present two methods for detecting Coffea arabica fields using remote sensing and geospatial technologies on WorldView-2 high-resolution spectral data of the Kona region of Hawaii Island. The first method, a pixel-based method using a maximum likelihood algorithm, attained 72% producer accuracy and 69% user accuracy (68% overall accuracy) based on analysis of 104 ground truth testing polygons. The second method, an object-based image analysis (OBIA) method, considered both spectral and textural information and improved accuracy, resulting in 76% producer accuracy and 94% user accuracy (81% overall accuracy) for the same testing areas. We conclude that the OBIA method is useful for detecting coffee fields grown in the open and use it to estimate the distribution of about 1050 hectares under coffee agriculture in the Kona region in 2012.

  12. A polyvalent harmonic coil testing method for small-aperture magnets

    NASA Astrophysics Data System (ADS)

    Arpaia, Pasquale; Buzio, Marco; Golluccio, Giancarlo; Walckiers, Louis

    2012-08-01

    A method to characterize permanent and fast-pulsed iron-dominated magnets with small apertures is presented. The harmonic coil measurement technique is enhanced specifically for small-aperture magnets by (1) in situ calibration, for facing search-coil production inaccuracy, (2) rotating the magnet around its axis, for correcting systematic effects, and (3) measuring magnetic fluxes by stationary coils at different angular positions for measuring fast pulsed magnets. This method allows a quadrupole magnet for particle accelerators to be characterized completely, by assessing multipole field components, magnetic axis position, and field direction. In this paper, initially the metrological problems arising from testing small-aperture magnets are highlighted. Then, the basic ideas of the proposed method and the architecture of the corresponding measurement system are illustrated. Finally, experimental validation results are shown for small-aperture permanent and fast-ramped quadrupole magnets for the new linear accelerator Linac4 at CERN (European Organization for Nuclear Research).

  13. Novel Control Scheme of Power Assisted Wheelchair for Preventing Overturn (Part I)-Adjustment of Assisted Torque and Performance Evaluation From Field Test-

    NASA Astrophysics Data System (ADS)

    Seki, Hirokazu; Hata, Naoki; Koyasu, Yuichi; Hori, Yoichi

    Aged people and disabled people who have difficulty in walking are increasing. As one of mobility support, significance of power assisted wheelchair which assists driving force using electric motors and spreads their living areas has been enhanced. However, the increased driving force often causes a dangerous overturn of wheelchair. In this paper, control method to prevent power assisted wheelchair from overturning is proposed. It is found the front wheels rising is caused by magnitude and rapid increase of assisted torque. Therefore, feedforward control method to limit the assisted torque by tuning its magnitude or time constant is proposed. In order to emphasize safety and feeling of security, these methods make the front wheels no rise. The effectiveness of the proposed method is verified by the practical experiments and field test based performance evaluation using many trial subjects.

  14. Drinking water test methods in crisis-afflicted areas: comparison of methods under field conditions.

    PubMed

    Merle, Roswitha; Bleul, Ingo; Schulenburg, Jörg; Kreienbrock, Lothar; Klein, Günter

    2011-11-01

    To simplify the testing of drinking water in crisis-afflicted areas (as in Kosovo in 2007), rapid test methods were compared with the standard test. For Escherichia coli and coliform pathogens, rapid tests were made available: Colilert(®)-18, P/A test with 4-methylumbelliferyl-β-D-glucoronid, and m-Endo Broth. Biochemical differentiation was carried out by Enterotube™ II. Enterococci were determined following the standard ISO test and by means of Enterolert™. Four hundred ninety-nine water samples were tested for E. coli and coliforms using four methods. Following the standard method, 20.8% (n=104) of the samples contained E. coli, whereas the rapid tests detected between 19.6% (m-Endo Broth, 92.0% concordance) and 20.0% (concordance: 93.6% Colilert-18 and 94.8% P/A-test) positive samples. Regarding coliforms, the percentage of concordant results ranged from 98.4% (P/A-test) to 99.0% (Colilert-18). Colilert-18 and m-Endo Broth detected even more positive samples than the standard method did. Enterococci were detected in 93 of 573 samples by the standard method, but in 92 samples by Enterolert (concordance: 99.5%). Considering the high-quality equipment and time requirements of the standard method, the use of rapid tests in crisis-afflicted areas is sufficiently reliable.

  15. Bayesian estimation of the transmissivity spatial structure from pumping test data

    NASA Astrophysics Data System (ADS)

    Demir, Mehmet Taner; Copty, Nadim K.; Trinchero, Paolo; Sanchez-Vila, Xavier

    2017-06-01

    Estimating the statistical parameters (mean, variance, and integral scale) that define the spatial structure of the transmissivity or hydraulic conductivity fields is a fundamental step for the accurate prediction of subsurface flow and contaminant transport. In practice, the determination of the spatial structure is a challenge because of spatial heterogeneity and data scarcity. In this paper, we describe a novel approach that uses time drawdown data from multiple pumping tests to determine the transmissivity statistical spatial structure. The method builds on the pumping test interpretation procedure of Copty et al. (2011) (Continuous Derivation method, CD), which uses the time-drawdown data and its time derivative to estimate apparent transmissivity values as a function of radial distance from the pumping well. A Bayesian approach is then used to infer the statistical parameters of the transmissivity field by combining prior information about the parameters and the likelihood function expressed in terms of radially-dependent apparent transmissivities determined from pumping tests. A major advantage of the proposed Bayesian approach is that the likelihood function is readily determined from randomly generated multiple realizations of the transmissivity field, without the need to solve the groundwater flow equation. Applying the method to synthetically-generated pumping test data, we demonstrate that, through a relatively simple procedure, information on the spatial structure of the transmissivity may be inferred from pumping tests data. It is also shown that the prior parameter distribution has a significant influence on the estimation procedure, given the non-uniqueness of the estimation procedure. Results also indicate that the reliability of the estimated transmissivity statistical parameters increases with the number of available pumping tests.

  16. Effect of a patient training video on visual field test reliability

    PubMed Central

    Sherafat, H; Spry, P G D; Waldock, A; Sparrow, J M; Diamond, J P

    2003-01-01

    Aims: To evaluate the effect of a visual field test educational video on the reliability of the first automated visual field test of new patients. Methods: A prospective, randomised, controlled trial of an educational video on visual field test reliability of patients referred to the hospital eye service for suspected glaucoma was undertaken. Patients were randomised to either watch an educational video or a control group with no video. The video group was shown a 4.5 minute audiovisual presentation to familiarise them with the various aspects of visual field examination with particular emphasis on sources of unreliability. Reliability was determined using standard criteria of fixation loss rate less than 20%, false positive responses less than 33%, and false negative responses less than 33%. Results: 244 patients were recruited; 112 in the video group and 132 in the control group with no significant between group difference in age, sex, and density of field defects. A significant improvement in reliability (p=0.015) was observed in the group exposed to the video with 85 (75.9%) patients having reliable results compared to 81 (61.4%) in the control group. The difference was not significant for the right (first tested) eye with 93 (83.0%) of the visual fields reliable in the video group compared to 106 (80.0%) in the control group (p = 0.583), but was significant for the left (second tested) eye with 97 (86.6 %) of the video group reliable versus 97 (73.5%) of the control group (p = 0.011). Conclusions: The use of a brief, audiovisual patient information guide on taking the visual field test produced an improvement in patient reliability for individuals tested for the first time. In this trial the use of the video had most of its impact by reducing the number of unreliable fields from the second tested eye. PMID:12543740

  17. Real-time management of an urban groundwater well field threatened by pollution.

    PubMed

    Bauser, Gero; Franssen, Harrie-Jan Hendricks; Kaiser, Hans-Peter; Kuhlmann, Ulrich; Stauffer, Fritz; Kinzelbach, Wolfgang

    2010-09-01

    We present an optimal real-time control approach for the management of drinking water well fields. The methodology is applied to the Hardhof field in the city of Zurich, Switzerland, which is threatened by diffuse pollution. The risk of attracting pollutants is higher if the pumping rate is increased and can be reduced by increasing artificial recharge (AR) or by adaptive allocation of the AR. The method was first tested in offline simulations with a three-dimensional finite element variably saturated subsurface flow model for the period January 2004-August 2005. The simulations revealed that (1) optimal control results were more effective than the historical control results and (2) the spatial distribution of AR should be different from the historical one. Next, the methodology was extended to a real-time control method based on the Ensemble Kalman Filter method, using 87 online groundwater head measurements, and tested at the site. The real-time control of the well field resulted in a decrease of the electrical conductivity of the water at critical measurement points which indicates a reduced inflow of water originating from contaminated sites. It can be concluded that the simulation and the application confirm the feasibility of the real-time control concept.

  18. Conceptual design of a Bitter-magnet toroidal-field system for the ZEPHYR Ignition Test Reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, J.E.C.; Becker, H.D.; Bobrov, E.S.

    1981-05-01

    The following problems are described and discussed: (1) parametric studies - these studies examine among other things the interdependence of throat stresses, plasma parameters (margins of ignition) and stored energy. The latter is a measure of cost and is minimized in the present design; (2) magnet configuration - the shape of the plates are considered in detail including standard turns, turns located at beam ports, diagnostic and closure flanges; (3) ripple computation - this section describes the codes by which ripple is computed; (4) field diffusion and nuclear heating - the effect of magnetic field diffusion on heating is consideredmore » along with neutron heating. Current, field and temperature profiles are computed; (5) finite element analysis - the two and three dimensional finite element codes are described and the results discussed in detail; (6) structures engineering - this considers the calculation of critical stresses due to toroidal and overturning forces and discusses the method of constraint of these forces. The Materials Testing Program is also discussed; (7) fabrication - the methods available for the manufacture of the constituent parts of the Bitter plates, the method of assembly and remote maintenance are summarized.« less

  19. Quantitative PCR detection of Batrachochytrium dendrobatidis DNA from sediments and water

    USGS Publications Warehouse

    Kirshtein, Julie D.; Anderson, Chauncey W.; Wood, J.S.; Longcore, Joyce E.; Voytek, Mary A.

    2007-01-01

    The fungal pathogen Batrachochytrium dendrobatidis (Bd) causes chytridiomycosis, a disease implicated in amphibian declines on 5 continents. Polymerase chain reaction (PCR) primer sets exist with which amphibians can be tested for this disease, and advances in sampling techniques allow non-invasive testing of animals. We developed filtering and PCR based quantitative methods by modifying existing PCR assays to detect Bd DNA in water and sediments, without the need for testing amphibians; we tested the methods at 4 field sites. The SYBR based assay using Boyle primers (SYBR/Boyle assay) and the Taqman based assay using Wood primers performed similarly with samples generated in the laboratory (Bd spiked filters), but the SYBR/Boyle assay detected Bd DNA in more field samples. We detected Bd DNA in water from 3 of 4 sites tested, including one pond historically negative for chytridiomycosis. Zoospore equivalents in sampled water ranged from 19 to 454 l-1 (nominal detection limit is 10 DNA copies, or about 0.06 zoospore). We did not detect DNA of Bd from sediments collected at any sites. Our filtering and amplification methods provide a new tool to investigate critical aspects of Bd in the environment. ?? Inter-Research 2007.

  20. Pumping tests in networks of multilevel sampling wells: Motivation and methodology

    USGS Publications Warehouse

    Butler, J.J.; McElwee, C.D.; Bohling, Geoffrey C.

    1999-01-01

    The identification of spatial variations in hydraulic conductivity (K) on a scale of relevance for transport investigations has proven to be a considerable challenge. Recently, a new field method for the estimation of interwell variations in K has been proposed. This method, hydraulic tomography, essentially consists of a series of short‐term pumping tests performed in a tomographic‐like arrangement. In order to fully realize the potential of this approach, information about lateral and vertical variations in pumping‐induced head changes (drawdown) is required with detail that has previously been unobtainable in the field. Pumping tests performed in networks of multilevel sampling (MLS) wells can provide data of the needed density if drawdown can accurately and rapidly be measured in the small‐diameter tubing used in such wells. Field and laboratory experiments show that accurate transient drawdown data can be obtained in the small‐diameter MLS tubing either directly with miniature fiber‐optic pressure sensors or indirectly using air‐pressure transducers. As with data from many types of hydraulic tests, the quality of drawdown measurements from MLS tubing is quite dependent on the effectiveness of well development activities. Since MLS ports of the standard design are prone to clogging and are difficult to develop, alternate designs are necessary to ensure accurate drawdown measurements. Initial field experiments indicate that drawdown measurements obtained from pumping tests performed in MLS networks have considerable potential for providing valuable information about spatial variations in hydraulic conductivity.

  1. Assessing sorbent injection mercury control effectiveness in flue gas streams

    USGS Publications Warehouse

    Carey, T.R.; Richardson, C.F.; Chang, R.; Meserole, F.B.; Rostam-Abadi, M.; Chen, S.

    2000-01-01

    One promising approach for removing mercury from coal-fired, utility flue gas involves the direct injection of mercury sorbents. Although this method has been effective at removing mercury in municipal waste incinerators, tests conducted to date on utility coal-fired boilers show that mercury removal is much more difficult in utility flue gas. EPRI is conducting research to investigate mercury removal using sorbents in this application. Bench-scale, pilot-scale, and field tests have been conducted to determine the ability of different sorbents to remove mercury in simulated and actual flue gas streams. This paper focuses on recent bench-scale and field test results evaluating the adsorption characteristics of activated carbon and fly ash and the use of these results to develop a predictive mercury removal model. Field tests with activated carbon show that adsorption characteristics measured in the lab agree reasonably well with characteristics measured in the field. However, more laboratory and field data will be needed to identify other gas phase components which may impact performance. This will allow laboratory tests to better simulate field conditions and provide improved estimates of sorbent performance for specific sites. In addition to activated carbon results, bench-scale and modeling results using fly ash are presented which suggest that certain fly ashes are capable of adsorbing mercury.

  2. A brain MRI bias field correction method created in the Gaussian multi-scale space

    NASA Astrophysics Data System (ADS)

    Chen, Mingsheng; Qin, Mingxin

    2017-07-01

    A pre-processing step is needed to correct for the bias field signal before submitting corrupted MR images to such image-processing algorithms. This study presents a new bias field correction method. The method creates a Gaussian multi-scale space by the convolution of the inhomogeneous MR image with a two-dimensional Gaussian function. In the multi-Gaussian space, the method retrieves the image details from the differentiation of the original image and convolution image. Then, it obtains an image whose inhomogeneity is eliminated by the weighted sum of image details in each layer in the space. Next, the bias field-corrected MR image is retrieved after the Υ correction, which enhances the contrast and brightness of the inhomogeneity-eliminated MR image. We have tested the approach on T1 MRI and T2 MRI with varying bias field levels and have achieved satisfactory results. Comparison experiments with popular software have demonstrated superior performance of the proposed method in terms of quantitative indices, especially an improvement in subsequent image segmentation.

  3. Improving record linkage performance in the presence of missing linkage data.

    PubMed

    Ong, Toan C; Mannino, Michael V; Schilling, Lisa M; Kahn, Michael G

    2014-12-01

    Existing record linkage methods do not handle missing linking field values in an efficient and effective manner. The objective of this study is to investigate three novel methods for improving the accuracy and efficiency of record linkage when record linkage fields have missing values. By extending the Fellegi-Sunter scoring implementations available in the open-source Fine-grained Record Linkage (FRIL) software system we developed three novel methods to solve the missing data problem in record linkage, which we refer to as: Weight Redistribution, Distance Imputation, and Linkage Expansion. Weight Redistribution removes fields with missing data from the set of quasi-identifiers and redistributes the weight from the missing attribute based on relative proportions across the remaining available linkage fields. Distance Imputation imputes the distance between the missing data fields rather than imputing the missing data value. Linkage Expansion adds previously considered non-linkage fields to the linkage field set to compensate for the missing information in a linkage field. We tested the linkage methods using simulated data sets with varying field value corruption rates. The methods developed had sensitivity ranging from .895 to .992 and positive predictive values (PPV) ranging from .865 to 1 in data sets with low corruption rates. Increased corruption rates lead to decreased sensitivity for all methods. These new record linkage algorithms show promise in terms of accuracy and efficiency and may be valuable for combining large data sets at the patient level to support biomedical and clinical research. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. A field method for making a quantitative estimate of altered tuff in sandstone

    USGS Publications Warehouse

    Cadigan, R.A.

    1954-01-01

    The use of benzidine to identify altered tuff in sandstone is practical for field or field laboratory studies associated with stratigraphic correlations, mineral deposit investigations, or paleogeographic interpretations. The method is based on the ability of saturated benzidine (C12H12N2) solution to produce a blue stain on montmorillonite-bearing tuff grains. The method is substantiated by the results of microscopic, X-ray spectrometer, and spectrographic tests which lead to the conclusion that: (1) the benzidine stain test differentiates grains of different composition, (2) the white or gray grains which are stained a uniform blue color are fragments of altered tuff, and (3) white or gray grains which stain in a few small spots are probably silicified tuff. The amount of sand grains taken from a hand specimen or an outcrop which will be held by a penny is spread out on a nonabsorbent white surface and soaked with benzidine for 5 minutes. The approximate number blue grains and the average grain size are used in a chart to determine a reference number which measures relative order of abundance. The chart, based on a volume relationship, corrects for the variation in the number of grains in the sample as the grain size varies. Practical use of the method depends on a knowledge of several precautionary measures as well as an understanding of the limitations of benzidine staining tests.

  5. Field test of electromagnetic geophysical techniques for locating simulated in situ mining leach solution. Report of investigations/1994

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tweeton, D.R.; Hanson, J.C.; Friedel, M.J.

    1994-01-01

    The U.S. Bureau of Mines, the University of Arizona, Sandia National Laboratory, and Zonge Engineering and Research, Inc., conducted cooperative field tests of six electromagnetic geophysical methods to compare their effectiveness in locating a brine solution simulating in situ leach solution or a high-conductivity plume of contamination. The brine was approximately 160 meters below the surface. The test site was the University's San Xavier experimental mine near Tucson, Arizona. Geophysical surveys using surface and surface-borehole time-domain electromagnetics (TEM), surface controlled source audio-frequency magnetotellurics (CSAMT), surface-borehole frequency-domain electromagnetics (FEM), crosshole FEM and surface magnetic field ellipticity were conducted before and duringmore » brine injection.« less

  6. Specvis: Free and open-source software for visual field examination.

    PubMed

    Dzwiniel, Piotr; Gola, Mateusz; Wójcik-Gryciuk, Anna; Waleszczyk, Wioletta J

    2017-01-01

    Visual field impairment affects more than 100 million people globally. However, due to the lack of the access to appropriate ophthalmic healthcare in undeveloped regions as a result of associated costs and expertise this number may be an underestimate. Improved access to affordable diagnostic software designed for visual field examination could slow the progression of diseases, such as glaucoma, allowing for early diagnosis and intervention. We have developed Specvis, a free and open-source application written in Java programming language that can run on any personal computer to meet this requirement (http://www.specvis.pl/). Specvis was tested on glaucomatous, retinitis pigmentosa and stroke patients and the results were compared to results using the Medmont M700 Automated Static Perimeter. The application was also tested for inter-test intrapersonal variability. The results from both validation studies indicated low inter-test intrapersonal variability, and suitable reliability for a fast and simple assessment of visual field impairment. Specvis easily identifies visual field areas of zero sensitivity and allows for evaluation of its levels throughout the visual field. Thus, Specvis is a new, reliable application that can be successfully used for visual field examination and can fill the gap between confrontation and perimetry tests. The main advantages of Specvis over existing methods are its availability (free), affordability (runs on any personal computer), and reliability (comparable to high-cost solutions).

  7. Specvis: Free and open-source software for visual field examination

    PubMed Central

    Dzwiniel, Piotr; Gola, Mateusz; Wójcik-Gryciuk, Anna

    2017-01-01

    Visual field impairment affects more than 100 million people globally. However, due to the lack of the access to appropriate ophthalmic healthcare in undeveloped regions as a result of associated costs and expertise this number may be an underestimate. Improved access to affordable diagnostic software designed for visual field examination could slow the progression of diseases, such as glaucoma, allowing for early diagnosis and intervention. We have developed Specvis, a free and open-source application written in Java programming language that can run on any personal computer to meet this requirement (http://www.specvis.pl/). Specvis was tested on glaucomatous, retinitis pigmentosa and stroke patients and the results were compared to results using the Medmont M700 Automated Static Perimeter. The application was also tested for inter-test intrapersonal variability. The results from both validation studies indicated low inter-test intrapersonal variability, and suitable reliability for a fast and simple assessment of visual field impairment. Specvis easily identifies visual field areas of zero sensitivity and allows for evaluation of its levels throughout the visual field. Thus, Specvis is a new, reliable application that can be successfully used for visual field examination and can fill the gap between confrontation and perimetry tests. The main advantages of Specvis over existing methods are its availability (free), affordability (runs on any personal computer), and reliability (comparable to high-cost solutions). PMID:29028825

  8. Constrained-transport Magnetohydrodynamics with Adaptive Mesh Refinement in CHARM

    NASA Astrophysics Data System (ADS)

    Miniati, Francesco; Martin, Daniel F.

    2011-07-01

    We present the implementation of a three-dimensional, second-order accurate Godunov-type algorithm for magnetohydrodynamics (MHD) in the adaptive-mesh-refinement (AMR) cosmological code CHARM. The algorithm is based on the full 12-solve spatially unsplit corner-transport-upwind (CTU) scheme. The fluid quantities are cell-centered and are updated using the piecewise-parabolic method (PPM), while the magnetic field variables are face-centered and are evolved through application of the Stokes theorem on cell edges via a constrained-transport (CT) method. The so-called multidimensional MHD source terms required in the predictor step for high-order accuracy are applied in a simplified form which reduces their complexity in three dimensions without loss of accuracy or robustness. The algorithm is implemented on an AMR framework which requires specific synchronization steps across refinement levels. These include face-centered restriction and prolongation operations and a reflux-curl operation, which maintains a solenoidal magnetic field across refinement boundaries. The code is tested against a large suite of test problems, including convergence tests in smooth flows, shock-tube tests, classical two- and three-dimensional MHD tests, a three-dimensional shock-cloud interaction problem, and the formation of a cluster of galaxies in a fully cosmological context. The magnetic field divergence is shown to remain negligible throughout.

  9. Methods of increasing the harshness of texture of old concrete pavements--acid etching.

    DOT National Transportation Integrated Search

    1975-01-01

    Of the four acids tested in the laboratory, the nitric and hydrochloric types were selected for field experiments. These two acids performed about equally well, the choice as to which to use is dictated by price and availability. In the field experim...

  10. Dynamic behaviors of historical wrought iron truss bridges: a field testing case study

    NASA Astrophysics Data System (ADS)

    Dai, Kaoshan; Wang, Ying; Hedric, Andrew; Huang, Zhenhua

    2016-04-01

    The U.S. transportation infrastructure has many wrought iron truss bridges that are more than a century old and still remain in use. Understanding the structural properties and identifying the health conditions of these historical bridges are essential to deciding the maintenance or rebuild plan of the bridges. This research involved an on-site full-scale system identification test case study on the historical Old Alton Bridge (a wrought iron truss bridge built in 1884 in Denton, Texas) using a wireless sensor network. The study results demonstrate a practical and convenient experimental system identification method for historical bridge structures. The method includes the basic steps of the in-situ experiment and in-house data analysis. Various excitation methods are studied for field testing, including ambient vibration by wind load, forced vibration by human jumping load, and forced vibration by human pulling load. Structural responses of the bridge under these different excitation approaches were analyzed and compared with numerical analysis results.

  11. Simple Statistical Model to Quantify Maximum Expected EMC in Spacecraft and Avionics Boxes

    NASA Technical Reports Server (NTRS)

    Trout, Dawn H.; Bremner, Paul

    2014-01-01

    This study shows cumulative distribution function (CDF) comparisons of composite a fairing electromagnetic field data obtained by computational electromagnetic 3D full wave modeling and laboratory testing. Test and model data correlation is shown. In addition, this presentation shows application of the power balance and extention of this method to predict the variance and maximum exptected mean of the E-field data. This is valuable for large scale evaluations of transmission inside cavities.

  12. Building America Case Study: Field Testing of Compartmentalization Methods for Multifamily Construction (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2015-01-01

    The 2012 IECC has an airtightness requirement of 3 air changes per hour at 50 Pascals test pressure for both single family and multifamily construction in Climate Zones 3-8. Other programs (LEED, ASHRAE 189, ASHRAE 62.2) have similar or tighter compartmentalization requirements, thus driving the need for easier and more effective methods of compartmentalization in multifamily buildings.

  13. Development of the methodology of exhaust emissions measurement under RDE (Real Driving Emissions) conditions for non-road mobile machinery (NRMM) vehicles

    NASA Astrophysics Data System (ADS)

    Merkisz, J.; Lijewski, P.; Fuc, P.; Siedlecki, M.; Ziolkowski, A.

    2016-09-01

    The paper analyzes the exhaust emissions from farm vehicles based on research performed under field conditions (RDE) according to the NTE procedure. This analysis has shown that it is hard to meet the NTE requirements under field conditions (engine operation in the NTE zone for at least 30 seconds). Due to a very high variability of the engine conditions, the share of a valid number of NTE windows in the field test is small throughout the entire test. For this reason, a modification of the measurement and exhaust emissions calculation methodology has been proposed for farm vehicles of the NRMM group. A test has been developed composed of the following phases: trip to the operation site (paved roads) and field operations (including u-turns and maneuvering). The range of the operation time share in individual test phases has been determined. A change in the method of calculating the real exhaust emissions has also been implemented in relation to the NTE procedure.

  14. Measurement and prediction of propeller flow field on the PTA aircraft at speeds of up to Mach 0.85. [Propfan Test Assessment

    NASA Technical Reports Server (NTRS)

    Aljabri, Abdullah S.

    1988-01-01

    High speed subsonic transports powered by advanced propellers provide significant fuel savings compared to turbofan powered transports. Unfortunately, however, propfans must operate in aircraft-induced nonuniform flow fields which can lead to high blade cyclic stresses, vibration and noise. To optimize the design and installation of these advanced propellers, therefore, detailed knowledge of the complex flow field is required. As part of the NASA Propfan Test Assessment (PTA) program, a 1/9 scale semispan model of the Gulfstream II propfan test-bed aircraft was tested in the NASA-Lewis 8 x 6 supersonic wind tunnel to obtain propeller flow field data. Detailed radial and azimuthal surveys were made to obtain the total pressure in the flow and the three components of velocity. Data was acquired for Mach numbers ranging from 0.6 to 0.85. Analytical predictions were also made using a subsonic panel method, QUADPAN. Comparison of wind-tunnel measurements and analytical predictions show good agreement throughout the Mach range.

  15. The Method of Fundamental Solutions using the Vector Magnetic Dipoles for Calculation of the Magnetic Fields in the Diagnostic Problems Based on Full-Scale Modelling Experiment

    NASA Astrophysics Data System (ADS)

    Bakhvalov, Yu A.; Grechikhin, V. V.; Yufanova, A. L.

    2016-04-01

    The article describes the calculation of the magnetic fields in the problems diagnostic of technical systems based on the full-scale modeling experiment. Use of gridless fundamental solution method and its variants in combination with grid methods (finite differences and finite elements) are allowed to considerably reduce the dimensionality task of the field calculation and hence to reduce calculation time. When implementing the method are used fictitious magnetic charges. In addition, much attention is given to the calculation accuracy. Error occurs when wrong choice of the distance between the charges. The authors are proposing to use vector magnetic dipoles to improve the accuracy of magnetic fields calculation. Examples of this approacharegiven. The article shows the results of research. They are allowed to recommend the use of this approach in the method of fundamental solutions for the full-scale modeling tests of technical systems.

  16. Maximum entropy reconstruction of poloidal magnetic field and radial electric field profiles in tokamaks

    NASA Astrophysics Data System (ADS)

    Chen, Yihang; Xiao, Chijie; Yang, Xiaoyi; Wang, Tianbo; Xu, Tianchao; Yu, Yi; Xu, Min; Wang, Long; Lin, Chen; Wang, Xiaogang

    2017-10-01

    The Laser-driven Ion beam trace probe (LITP) is a new diagnostic method for measuring poloidal magnetic field (Bp) and radial electric field (Er) in tokamaks. LITP injects a laser-driven ion beam into the tokamak, and Bp and Er profiles can be reconstructed using tomography methods. A reconstruction code has been developed to validate the LITP theory, and both 2D reconstruction of Bp and simultaneous reconstruction of Bp and Er have been attained. To reconstruct from experimental data with noise, Maximum Entropy and Gaussian-Bayesian tomography methods were applied and improved according to the characteristics of the LITP problem. With these improved methods, a reconstruction error level below 15% has been attained with a data noise level of 10%. These methods will be further tested and applied in the following LITP experiments. Supported by the ITER-CHINA program 2015GB120001, CHINA MOST under 2012YQ030142 and National Natural Science Foundation Abstract of China under 11575014 and 11375053.

  17. Methods of Collecting and Analyzing Rearward Visibility Data for Agricultural Machinery: Hazard and/or Object Detectability.

    PubMed

    Ehlers, Shawn G; Field, William E; Ess, Daniel R

    2017-01-26

    Recent interest in rearward visibility for private, construction, and commercial vehicles and documentation of rearward runovers involving bystanders outside the field of vision of the vehicle operator led to an investigation into the need for enhanced methods of rearward visibility for large, off-highway, agricultural equipment. A review of the literature found limited relevant research and minimal data on incidents involving rearward runovers of bystanders and co-workers. This article reviews the findings regarding the methods identified and tested to collect and analyze rearward visibility data, from the operator's perspective, for large self-propelled agricultural equipment, including the four-wheel drive tractors, combines, agricultural sprayers, and skid-steer loaders that are increasingly found on agricultural production sites. The methods identified, largely drawn from research conducted on private and commercial vehicles, were tested to determine their application in identifying rearward blind spots. These methods are described, and the findings from field-testing of specific machines are provided. Recommendations include establishing an appropriate engineering standard regarding rearward visibility of agricultural equipment with limited rearward vision and the use of rearward alarm systems for warning bystanders of rearward movement. Copyright© by the American Society of Agricultural Engineers.

  18. Mathematical Geology

    ERIC Educational Resources Information Center

    Merriam, Daniel F.

    1978-01-01

    Geomathematics is a developing field that is being used in practical applications. Classification is an important element and the dynamic-cluster method (DCM), a nonhierarchial procedure, was introduced this past year. A method for testing the degree of cluster distinctness was developed also. (MA)

  19. Description and evaluation of an interference assessment for a slotted-wall wind tunnel

    NASA Technical Reports Server (NTRS)

    Kemp, William B., Jr.

    1991-01-01

    A wind-tunnel interference assessment method applicable to test sections with discrete finite-length wall slots is described. The method is based on high order panel method technology and uses mixed boundary conditions to satisfy both the tunnel geometry and wall pressure distributions measured in the slotted-wall region. Both the test model and its sting support system are represented by distributed singularities. The method yields interference corrections to the model test data as well as surveys through the interference field at arbitrary locations. These results include the equivalent of tunnel Mach calibration, longitudinal pressure gradient, tunnel flow angularity, wall interference, and an inviscid form of sting interference. Alternative results which omit the direct contribution of the sting are also produced. The method was applied to the National Transonic Facility at NASA Langley Research Center for both tunnel calibration tests and tests of two models of subsonic transport configurations.

  20. Study on the electromagnetic radiation characteristics of discharging excimer laser system

    NASA Astrophysics Data System (ADS)

    Zhao, Duliang; Liang, Xu; Fang, Xiaodong; Wang, Qingsheng

    2016-10-01

    Excimer laser in condition of high voltage, large current and fast discharge will produce strong electromagnetic pulse radiation and electromagnetic interference on the around electrical equipment. The research on characteristics and distribution of excimer laser electromagnetic radiation could provide important basis for electromagnetic shielding and suppressing electromagnetic interference, and further improving the electromagnetic compatibility of system. Firstly, electromagnetic radiation source is analyzed according to the working principle of excimer laser. The key test points of the electromagnetic radiation, hydrogen thyratron, main discharge circuit and laser outlet, are determined by the mechanical structure and the theory of electromagnetic radiation. Secondly, characteristics of electromagnetic field were tested using a near field probe on the key positions of the vertical direction at 20, 50, and 80 cm, respectively. The main radiation frequencies and the radiation field characteristics in the near field are obtained. The experimental results show that the main radiation frequencies distribute in 47, 65, and 130 MHz for electric field and the main radiation frequencies distribute in 34, 100, and 165 MHz for magnetic field. The intensity of electromagnetic field decreases rapidly with the increase of test distance. The higher the frequency increases, the faster the amplitude attenuate. Finally, several electromagnetic interference suppression measurement methods are proposed from the perspective of electromagnetic compatibility according to the test results.

  1. Developing new extension of GafChromic RTQA2 film to patient quality assurance field using a plan-based calibration method

    NASA Astrophysics Data System (ADS)

    Peng, Jiayuan; Zhang, Zhen; Wang, Jiazhou; Xie, Jiang; Chen, Junchao; Hu, Weigang

    2015-10-01

    GafChromic RTQA2 film is a type of radiochromic film designed for light field and radiation field alignment. The aim of this study is to extend the application of RTQA2 film to the measurement of patient specific quality assurance (QA) fields as a 2D relative dosimeter. Pre-irradiated and post-irradiated RTQA2 films were scanned in reflection mode using a flatbed scanner. A plan-based calibration (PBC) method utilized the mapping information of the calculated dose image and film grayscale image to create a dose versus pixel value calibration model. This model was used to calibrate the film grayscale image to the film relative dose image. The dose agreement between calculated and film dose images were analyzed by gamma analysis. To evaluate the feasibility of this method, eight clinically approved RapidArc cases (one abdomen cancer and seven head-and-neck cancer patients) were tested using this method. Moreover, three MLC gap errors and two MLC transmission errors were introduced to eight Rapidarc cases respectively to test the robustness of this method. The PBC method could overcome the film lot and post-exposure time variations of RTQA2 film to get a good 2D relative dose calibration result. The mean gamma passing rate of eight patients was 97.90%  ±  1.7%, which showed good dose consistency between calculated and film dose images. In the error test, the PBC method could over-calibrate the film, which means some dose error in the film would be falsely corrected to keep the dose in film consistent with the dose in the calculated dose image. This would then lead to a false negative result in the gamma analysis. In these cases, the derivative curve of the dose calibration curve would be non-monotonic which would expose the dose abnormality. By using the PBC method, we extended the application of more economical RTQA2 film to patient specific QA. The robustness of the PBC method has been improved by analyzing the monotonicity of the derivative of the calibration curve.

  2. Combined ultraviolet and water exposure as a preconditioning method in laboratory fungal durability testing

    Treesearch

    Rebecca E. Ibach; Craig M. Clemons; Nicole M. Stark

    2003-01-01

    During outdoor exposure, woodfiber-plastic composites (WPC) are subject to biological, moisture, and ultraviolet (UV) degradation. The purpose of laboratory evaluations is to simulate outdoor conditions and accelerate the testing for quicker results. Traditionally, biological, moisture, and W laboratory tests are done separately, and only combined in outdoor field...

  3. Retrieving Storm Electric Fields From Aircraft Field Mill Data. Part 2; Applications

    NASA Technical Reports Server (NTRS)

    Koshak, W. J.; Mach, D. M.; Christian, H. J.; Stewart, M. F.; Bateman, M. G.

    2005-01-01

    The Lagrange multiplier theory and "pitch down method" developed in Part I of this study are applied to complete the calibration of a Citation aircraft that is instrumented with six field mill sensors. When side constraints related to average fields are used, the method performs well in computer simulations. For mill measurement errors of 1 V/m and a 5 V/m error in the mean fair weather field function, the 3-D storm electric field is retrieved to within an error of about 12%. A side constraint that involves estimating the detailed structure of the fair weather field was also tested using computer simulations. For mill measurement errors of 1 V/m, the method retrieves the 3-D storm field to within an error of about 8% if the fair weather field estimate is typically within 1 V/m of the true fair weather field. Using this side constraint and data from fair weather field maneuvers taken on 29 June 2001, the Citation aircraft was calibrated. The resulting calibration matrix was then used to retrieve storm electric fields during a Citation flight on 2 June 2001. The storm field results are encouraging and agree favorably with the results obtained from earlier calibration analyses that were based on iterative techniques.

  4. A method for spatial regularisation of a bunch of filaments in a femtosecond laser pulse

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kandidov, V P; Kosareva, O G; Nyakk, A V

    A method for spatial regularisation of chaotically located filaments, which appear in a high-power femtosecond laser pulse, is proposed, numerically substantiated, and experimentally tested. This method is based on the introduction of regular light-field perturbations into the femtosecond-pulse cross section. (letters)

  5. A genuinely discontinuous approach for multiphase EHD problems

    NASA Astrophysics Data System (ADS)

    Natarajan, Mahesh; Desjardins, Olivier

    2017-11-01

    Electrohydrodynamics (EHD) involves solving the Poisson equation for the electric field potential. For multiphase flows, although the electric field potential is a continuous quantity, due to the discontinuity in the electric permittivity between the phases, additional jump conditions at the interface, for the normal and tangential components of the electric field need to be satisfied. All approaches till date either ignore the jump conditions, or involve simplifying assumptions, and hence yield unconvincing results even for simple test problems. In the present work, we develop a genuinely discontinuous approach for the Poisson equation for multiphase flows using a Finite Volume Unsplit Volume of Fluid method. The governing equation and the jump conditions without assumptions are used to develop the method, and its efficiency is demonstrated by comparison of the numerical results with canonical test problems having exact solutions. Postdoctoral Associate, Department of Mechanical and Aerospace Engineering.

  6. Field evaluation of an avian risk assessment model

    USGS Publications Warehouse

    Vyas, N.B.; Spann, J.W.; Hulse, C.S.; Borges, S.L.; Bennett, R.S.; Torrez, M.; Williams, B.I.; Leffel, R.

    2006-01-01

    We conducted two laboratory subacute dietary toxicity tests and one outdoor subacute dietary toxicity test to determine the effectiveness of the U.S. Environmental Protection Agency's deterministic risk assessment model for evaluating the potential of adverse effects to birds in the field. We tested technical-grade diazinon and its D Z N- 50W (50% diazinon active ingredient wettable powder) formulation on Canada goose (Branta canadensis) goslings. Brain acetylcholinesterase activity was measured, and the feathers and skin, feet. and gastrointestinal contents were analyzed for diazinon residues. The dose-response curves showed that diazinon was significantly more toxic to goslings in the outdoor test than in the laboratory tests. The deterministic risk assessment method identified the potential for risk to birds in general, but the factors associated with extrapolating from the laboratory to the field, and from the laboratory test species to other species, resulted in the underestimation of risk to the goslings. The present study indicates that laboratory-based risk quotients should be interpreted with caution.

  7. Hydrogeologic data from test drilling near Verna, Florida, 1978

    USGS Publications Warehouse

    Barker, Michael; Bowman, Geronia; Sutcliffe, Horace

    1981-01-01

    Four test wells were drilled in the vicinity of the city of Sarasota well field near Verna, Fla., to provide hydrologic and geologic information. An expedient and economical method of air lifting water samples from isolated water-producing zones while drilling was utilized. Lithologic logs of drill cuttings and geophysical logs, including point resistance and spontaneous potential electric logs, gamma-ray logs, and caliper logs, were made. Chemical quality of water was determined for principal producing zones at each well. Dissolved solids from composite water samples ranged from 313 milligrams per liter in test well 0-1 north of the well field to 728 milligrams per liter in test well 0-3 within the well field. Each test well was pumped to determine maximum discharge, water-level drawdown, and recovery time. A leaking pump column on test well 0-1 prevented accurate measurement of drawdown on the well. Test well 0-2, located east of the well field, had a pumping rate of 376 gallons per minute and 13.11 feet of drawdown after 3 hours and 50 minutes; test well 0-3 had a maximum yield of 320 gallons per minute, a drawdown of 31.91 feet after 2 hours and 35 minutes of pumping, had a recovery time of 20 minutes; and test well 0-4, south of the well field, had a pumping rate of 200 gallons per minute with 63.34 feet of drawdown after 2 hours and 35 minutes. (USGS)

  8. [Comparative analysis between diatom nitric acid digestion method and plankton 16S rDNA PCR method].

    PubMed

    Han, Jun-ge; Wang, Cheng-bao; Li, Xing-biao; Fan, Yan-yan; Feng, Xiang-ping

    2013-10-01

    To compare and explore the application value of diatom nitric acid digestion method and plankton 16S rDNA PCR method for drowning identification. Forty drowning cases from 2010 to 2011 were collected from Department of Forensic Medicine of Wenzhou Medical University. Samples including lung, kidney, liver and field water from each case were tested with diatom nitric acid digestion method and plankton 16S rDNA PCR method, respectively. The Diatom nitric acid digestion method and plankton 16S rDNA PCR method required 20 g and 2 g of each organ, and 15 mL and 1.5 mL of field water, respectively. The inspection time and detection rate were compared between the two methods. Diatom nitric acid digestion method mainly detected two species of diatoms, Centriae and Pennatae, while plankton 16S rDNA PCR method amplified a length of 162 bp band. The average inspection time of each case of the Diatom nitric acid digestion method was (95.30 +/- 2.78) min less than (325.33 +/- 14.18) min of plankton 16S rDNA PCR method (P < 0.05). The detection rates of two methods for field water and lung were both 100%. For liver and kidney, the detection rate of plankton 16S rDNA PCR method was both 80%, higher than 40% and 30% of diatom nitric acid digestion method (P < 0.05), respectively. The laboratory testing method needs to be appropriately selected according to the specific circumstances in the forensic appraisal of drowning. Compared with diatom nitric acid digestion method, plankton 16S rDNA PCR method has practice values with such advantages as less quantity of samples, huge information and high specificity.

  9. Nuclear Technology. Course 32: Nondestructive Examination (NDE) II. Module 32-3, Fundamentals of Magnetic Particle Testing.

    ERIC Educational Resources Information Center

    Groseclose, Richard

    This third in a series of six modules for a course titled Nondestructive Examination (NDE) Techniques II explains the principles of magnets and magnetic fields and how they are applied in magnetic particle testing, describes the theory and methods of magnetizing test specimens, describes the test equipment used, discusses the principles and…

  10. Soil-contact decay tests using small blocks : a procedural analysis

    Treesearch

    Rodney C. De Groot; James W. Evans; Paul G. Forsyth; Camille M. Freitag; Jeffrey J. Morrell

    Much discussion has been held regarding the merits of laboratory decay tests compared with field tests to evaluate wood preservatives. In this study, procedural aspects of soil jar decay tests with 1 cm 3 blocks were critically examined. Differences among individual bottles were a major source of variation in this method. The reproducibility and sensitivity of the soil...

  11. A median filter approach for correcting errors in a vector field

    NASA Technical Reports Server (NTRS)

    Schultz, H.

    1985-01-01

    Techniques are presented for detecting and correcting errors in a vector field. These methods employ median filters which are frequently used in image processing to enhance edges and remove noise. A detailed example is given for wind field maps produced by a spaceborne scatterometer. The error detection and replacement algorithm was tested with simulation data from the NASA Scatterometer (NSCAT) project.

  12. Framework for Testing the Effectiveness of Bat and Eagle Impact-Reduction Strategies at Wind Energy Projects

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sinclair, Karin; DeGeorge, Elise

    2016-04-13

    The objectives of this framework are to facilitate the study design and execution to test the effectiveness of bat and eagle impact-reduction strategies at wind energy sites. Through scientific field research, the wind industry and its partners can help determine if certain strategies are ready for operational deployment or require further development. This framework should be considered a living document to be improved upon as fatality-reduction technologies advance from the initial concepts to proven readiness (through project- and technology-specific testing) and as scientific field methods improve.

  13. Beta Testing in Social Work

    ERIC Educational Resources Information Center

    Traube, Dorian E.; Begun, Stephanie; Petering, Robin; Flynn, Marilyn L.

    2017-01-01

    The field of social work does not currently have a widely adopted method for expediting innovations into micro- or macropractice. Although it is common in fields such as engineering and business to have formal processes for accelerating scientific advances into consumer markets, few comparable mechanisms exist in the social sciences or social…

  14. A Semi-Analytical Method for Determining the Energy Release Rate of Cracks in Adhesively-Bonded Single-Lap Composite Joints

    NASA Technical Reports Server (NTRS)

    Yang, Charles; Sun, Wenjun; Tomblin, John S.; Smeltzer, Stanley S., III

    2007-01-01

    A semi-analytical method for determining the strain energy release rate due to a prescribed interface crack in an adhesively-bonded, single-lap composite joint subjected to axial tension is presented. The field equations in terms of displacements within the joint are formulated by using first-order shear deformable, laminated plate theory together with kinematic relations and force equilibrium conditions. The stress distributions for the adherends and adhesive are determined after the appropriate boundary and loading conditions are applied and the equations for the field displacements are solved. Based on the adhesive stress distributions, the forces at the crack tip are obtained and the strain energy release rate of the crack is determined by using the virtual crack closure technique (VCCT). Additionally, the test specimen geometry from both the ASTM D3165 and D1002 test standards are utilized during the derivation of the field equations in order to correlate analytical models with future test results. The system of second-order differential field equations is solved to provide the adherend and adhesive stress response using the symbolic computation tool, Maple 9. Finite element analyses using J-integral as well as VCCT were performed to verify the developed analytical model. The finite element analyses were conducted using the commercial finite element analysis software ABAQUS. The results determined using the analytical method correlated well with the results from the finite element analyses.

  15. Detection of Papaya leaf distortion mosaic virus by reverse-transcription loop-mediated isothermal amplification.

    PubMed

    Shen, Wentao; Tuo, Decai; Yan, Pu; Li, Xiaoying; Zhou, Peng

    2014-01-01

    Papaya leaf distortion mosaic virus (PLDMV) can infect transgenic papaya resistant to a related pathogen, Papaya ringspot virus (PRSV), posing a substantial threat to papaya production in China. Current detection methods, however, are unable to be used for rapid detection in the field. Here, a reverse-transcription loop-mediated isothermal amplification (RT-LAMP) assay was developed for the detection of PLDMV, using a set of four RT-LAMP primers designed based on the conserved sequence of PLDMV CP. The RT-LAMP method detected specifically PLDMV and was highly sensitive, with a detection limit of 1.32×10(-6) μg of total RNA per reaction. Indeed, the reaction was 10 times more sensitive than one-step RT-PCR, while also requiring significantly less time and equipment. The effectiveness of RT-LAMP and one-step RT-PCR in detecting the virus were compared using 90 field samples of non-transgenic papaya and 90 field samples of commercialized PRSV-resistant transgenic papaya from Hainan Island. None of the non-transgenic papaya tested positive for PLDMV using either method. In contrast, 19 of the commercialized PRSV-resistant transgenic papaya samples tested positive by RT-LAMP assay, and 6 of those tested negative by RT-PCR. Therefore, the PLDMV-specific RT-LAMP is a simple, rapid, sensitive, and cost-effective tool in the field diagnosis and control of PLDMV. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Combined use of field and laboratory testing to predict preferred flow paths in an heterogeneous aquifer.

    PubMed

    Gierczak, R F D; Devlin, J F; Rudolph, D L

    2006-01-05

    Elevated nitrate concentrations within a municipal water supply aquifer led to pilot testing of a field-scale, in situ denitrification technology based on carbon substrate injections. In advance of the pilot test, detailed characterization of the site was undertaken. The aquifer consisted of complex, discontinuous and interstratified silt, sand and gravel units, similar to other well studied aquifers of glaciofluvial origin, 15-40 m deep. Laboratory and field tests, including a conservative tracer test, a pumping test, a borehole flowmeter test, grain-size analysis of drill cuttings and core material, and permeameter testing performed on core samples, were performed on the most productive depth range (27-40 m), and the results were compared. The velocity profiles derived from the tracer tests served as the basis for comparison with other methods. The spatial variation in K, based on grain-size analysis, using the Hazen method, were poorly correlated with the breakthrough data. Trends in relative hydraulic conductivity (K/K(avg)) from permeameter testing compared somewhat better. However, the trends in transient drawdown with depth, measured in multilevel sampling points, corresponded particularly well with those of solute mass flux. Estimates of absolute K, based on standard pumping test analysis of the multilevel drawdown data, were inversely correlated with the tracer test data. The inverse nature of the correlation was attributed to assumptions in the transient drawdown packages that were inconsistent with the variable diffusivities encountered at the scale of the measurements. Collectively, the data showed that despite a relatively low variability in K within the aquifer under study (within a factor of 3), water and solute mass fluxes were concentrated in discrete intervals that could be targeted for later bioremediation.

  17. [Rapid laboratory detection of antigens of infective agents of infections and technical means for their realization].

    PubMed

    Kal'noĭ, S M

    2003-01-01

    A system of new accelerated and rapid methods for the detection of the antigens of the infective agents of plague, cholera, tularemia and brucellosis were developed on the basis of solid phase immunosuspension tests: the passive hemagglutination (PHA) test and the latex agglutination (LA) test. The immunological and physico-chemical properties of suspensions in the PHA and LA tests made it possible to use extraneous sources of energy (centrifugal acceleration and the electric field) to accelerate these tests. The results of the PHA and LA tests were registered with the use of a densitometer, model Ultrascan 2202, and a tester, model C 34014.2. To apply centrifugal acceleration and the electric field, a laboratory centrifuge and an electrophoretic microchamber were designed. Densitometry was carried out on modified plates and conductometry, with the use of modified electrodes. The time of obtaining the results of the PHA and LA tests was 15-30 minutes with the use of centrifugation and 2-5 minutes in the electric field, which made it possible to regard these tests as rapid.

  18. Introduction of steered molecular dynamics into UNRES coarse-grained simulations package.

    PubMed

    Sieradzan, Adam K; Jakubowski, Rafał

    2017-03-30

    In this article, an implementation of steered molecular dynamics (SMD) in coarse-grain UNited RESidue (UNRES) simulations package is presented. Two variants of SMD have been implemented: with a constant force and a constant velocity. The huge advantage of SMD implementation in the UNRES force field is that it allows to pull with the speed significantly lower than the accessible pulling speed in simulations with all-atom representation of a system, with respect to a reasonable computational time. Therefore, obtaining pulling speed closer to those which appear in the atomic force spectroscopy is possible. The newly implemented method has been tested for behavior in a microcanonical run to verify the influence of introduction of artificial constrains on keeping total energy of the system. Moreover, as time dependent artificial force was introduced, the thermostat behavior was tested. The new method was also tested via unfolding of the Fn3 domain of human contactin 1 protein and the I27 titin domain. Obtained results were compared with Gø-like force field, all-atom force field, and experimental results. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  19. Characterization of the onboard imaging unit for the first clinical magnetic resonance image guided radiation therapy system.

    PubMed

    Hu, Yanle; Rankine, Leith; Green, Olga L; Kashani, Rojano; Li, H Harold; Li, Hua; Nana, Roger; Rodriguez, Vivian; Santanam, Lakshmi; Shvartsman, Shmaryu; Victoria, James; Wooten, H Omar; Dempsey, James F; Mutic, Sasa

    2015-10-01

    To characterize the performance of the onboard imaging unit for the first clinical magnetic resonance image guided radiation therapy (MR-IGRT) system. The imaging performance characterization included four components: ACR (the American College of Radiology) phantom test, spatial integrity, coil signal to noise ratio (SNR) and uniformity, and magnetic field homogeneity. The ACR phantom test was performed in accordance with the ACR phantom test guidance. The spatial integrity test was evaluated using a 40.8 × 40.8 × 40.8 cm(3) spatial integrity phantom. MR and computed tomography (CT) images of the phantom were acquired and coregistered. Objects were identified around the surfaces of 20 and 35 cm diameters of spherical volume (DSVs) on both the MR and CT images. Geometric distortion was quantified using deviation in object location between the MR and CT images. The coil SNR test was performed according to the national electrical manufacturers association (NEMA) standards MS-1 and MS-9. The magnetic field homogeneity test was measured using field camera and spectral peak methods. For the ACR tests, the slice position error was less than 0.10 cm, the slice thickness error was less than 0.05 cm, the resolved high-contrast spatial resolution was 0.09 cm, the resolved low-contrast spokes were more than 25, the image intensity uniformity was above 93%, and the percentage ghosting was less than 0.22%. All were within the ACR recommended specifications. The maximum geometric distortions within the 20 and 35 cm DSVs were 0.10 and 0.18 cm for high spatial resolution three-dimensional images and 0.08 and 0.20 cm for high temporal resolution two dimensional cine images based on the distance-to-phantom-center method. The average SNR was 12.0 for the body coil, 42.9 for the combined torso coil, and 44.0 for the combined head and neck coil. Magnetic field homogeneities at gantry angles of 0°, 30°, 60°, 90°, and 120° were 23.55, 20.43, 18.76, 19.11, and 22.22 ppm, respectively, using the field camera method over the 45 cm DSV. The onboard imaging unit of the first commercial MR-IGRT system meets ACR, NEMA, and vendor specifications.

  20. Assessing ConnDOT's portland cement concrete testing methods phase II : field trials and implementation.

    DOT National Transportation Integrated Search

    2012-04-01

    This paper presents a description of efforts to disseminate findings from the Phase I study (SPR-2244), provides examples of applied maturity testing and temperature monitoring in Connecticut, reviews several State Highway Agency protocols for using ...

  1. Chemical free cotton defoliation and dessication

    USDA-ARS?s Scientific Manuscript database

    Preliminary results are presented for new techniques to achieve chemical free means of cotton defoliation and desiccation. Report will cover test results, for several different methods, as tested on; greenhouse, outdoor grown potted plants, and field grown cotton plants, that were grown under commer...

  2. Point focusing using loudspeaker arrays from the perspective of optimal beamforming.

    PubMed

    Bai, Mingsian R; Hsieh, Yu-Hao

    2015-06-01

    Sound focusing is to create a concentrated acoustic field in the region surrounded by a loudspeaker array. This problem was tackled in the previous research via the Helmholtz integral approach, brightness control, acoustic contrast control, etc. In this paper, the same problem was revisited from the perspective of beamforming. A source array model is reformulated in terms of the steering matrix between the source and the field points, which lends itself to the use of beamforming algorithms such as minimum variance distortionless response (MVDR) and linearly constrained minimum variance (LCMV) originally intended for sensor arrays. The beamforming methods are compared with the conventional methods in terms of beam pattern, directional index, and control effort. Objective tests are conducted to assess the audio quality by using perceptual evaluation of audio quality (PEAQ). Experiments of produced sound field and listening tests are conducted in a listening room, with results processed using analysis of variance and regression analysis. In contrast to the conventional energy-based methods, the results have shown that the proposed methods are phase-sensitive in light of the distortionless constraint in formulating the array filters, which helps enhance audio quality and focusing performance.

  3. Operational modal analysis of a high-rise multi-function building with dampers by a Bayesian approach

    NASA Astrophysics Data System (ADS)

    Ni, Yanchun; Lu, Xilin; Lu, Wensheng

    2017-03-01

    The field non-destructive vibration test plays an important role in the area of structural health monitoring. It assists in monitoring the health status and reducing the risk caused by the poor performance of structures. As the most economic field test among the various vibration tests, the ambient vibration test is the most popular and is widely used to assess the physical condition of a structure under operational service. Based on the ambient vibration data, modal identification can help provide significant previous study for model updating and damage detection during the service life of a structure. It has been proved that modal identification works well in the investigation of the dynamic performance of different kinds of structures. In this paper, the objective structure is a high-rise multi-function office building. The whole building is composed of seven three-story structural units. Each unit comprises one complete floor and two L shaped floors to form large spaces along the vertical direction. There are 56 viscous dampers installed in the building to improve the energy dissipation capacity. Due to the special feature of the structure, field vibration tests and further modal identification were performed to investigate its dynamic performance. Twenty-nine setups were designed to cover all the degrees of freedom of interest. About two years later, another field test was carried out to measure the building for 48 h to investigate the performance variance and the distribution of the modal parameters. A Fast Bayesian FFT method was employed to perform the modal identification. This Bayesian method not only provides the most probable values of the modal parameters but also assesses the associated posterior uncertainty analytically, which is especially relevant in field vibration tests arising due to measurement noise, sensor alignment error, modelling error, etc. A shaking table test was also implemented including cases with and without dampers, which assists in investigating the effect of dampers. The modal parameters obtained from different tests were investigated separately and then compared with each other.

  4. Field test comparison of an autocorrelation technique for determining grain size using a digital 'beachball' camera versus traditional methods

    USGS Publications Warehouse

    Barnard, P.L.; Rubin, D.M.; Harney, J.; Mustain, N.

    2007-01-01

    This extensive field test of an autocorrelation technique for determining grain size from digital images was conducted using a digital bed-sediment camera, or 'beachball' camera. Using 205 sediment samples and >1200 images from a variety of beaches on the west coast of the US, grain size ranging from sand to granules was measured from field samples using both the autocorrelation technique developed by Rubin [Rubin, D.M., 2004. A simple autocorrelation algorithm for determining grain size from digital images of sediment. Journal of Sedimentary Research, 74(1): 160-165.] and traditional methods (i.e. settling tube analysis, sieving, and point counts). To test the accuracy of the digital-image grain size algorithm, we compared results with manual point counts of an extensive image data set in the Santa Barbara littoral cell. Grain sizes calculated using the autocorrelation algorithm were highly correlated with the point counts of the same images (r2 = 0.93; n = 79) and had an error of only 1%. Comparisons of calculated grain sizes and grain sizes measured from grab samples demonstrated that the autocorrelation technique works well on high-energy dissipative beaches with well-sorted sediment such as in the Pacific Northwest (r2 ??? 0.92; n = 115). On less dissipative, more poorly sorted beaches such as Ocean Beach in San Francisco, results were not as good (r2 ??? 0.70; n = 67; within 3% accuracy). Because the algorithm works well compared with point counts of the same image, the poorer correlation with grab samples must be a result of actual spatial and vertical variability of sediment in the field; closer agreement between grain size in the images and grain size of grab samples can be achieved by increasing the sampling volume of the images (taking more images, distributed over a volume comparable to that of a grab sample). In all field tests the autocorrelation method was able to predict the mean and median grain size with ???96% accuracy, which is more than adequate for the majority of sedimentological applications, especially considering that the autocorrelation technique is estimated to be at least 100 times faster than traditional methods.

  5. Non-Contact Stiffness Measurement of a Suspended Single Walled Carbon Nanotube Device

    NASA Technical Reports Server (NTRS)

    Zheng, Yun; Su, Chanmin; Getty, Stephanie

    2010-01-01

    A new nanoscale electric field sensor was developed for studying triboelectric charging in terrestrial and Martian dust devils. This sensor is capable to measure the large electric fields for large dust devils without saturation. However, to quantify the electric charges and the field strength it is critical to calibrate the mechanical stiffness of the sensor devices. We performed a technical feasibility study of the Nano E-field Sensor stiffness by a non-contact stiffness measurement method. The measurement is based on laser Doppler vibrometer measurement of the thermal noise due to energy flunctuations in the devices. The experiment method provides a novel approach to acquire data that is essential in analyzing the quantitative performance of the E-field Nano Sensor. To carry out the non-contact stiffness measurement, we fabricated a new Single-Walled Carbon Nanotube (SWCNT) E-field sensor with different SWCNTs suspension conditions. The power spectra of the thermal induced displacement in the nano E-field sensor were measured at the accuracy of picometer. The power spectra were then used to derive the mechanical stiffness of the sensors. Effect of suspension conditions on stiffness and sensor sensitivty was discussed. After combined deformation and resistivity measurement, we can compare with our laboratory testing and field testing results. This new non-contact measurement technology can also help to explore to other nano and MEMS devices in the future.

  6. Optimization of Pockels electric field in transverse modulated optical voltage sensor

    NASA Astrophysics Data System (ADS)

    Huang, Yifan; Xu, Qifeng; Chen, Kun-Long; Zhou, Jie

    2018-05-01

    This paper investigates the possibilities of optimizing the Pockels electric field in a transverse modulated optical voltage sensor with a spherical electrode structure. The simulations show that due to the edge effect and the electric field concentrations and distortions, the electric field distributions in the crystal are non-uniform. In this case, a tiny variation in the light path leads to an integral error of more than 0.5%. Moreover, a 2D model cannot effectively represent the edge effect, so a 3D model is employed to optimize the electric field distributions. Furthermore, a new method to attach a quartz crystal to the electro-optic crystal along the electric field direction is proposed to improve the non-uniformity of the electric field. The integral error is reduced therefore from 0.5% to 0.015% and less. The proposed method is simple, practical and effective, and it has been validated by numerical simulations and experimental tests.

  7. Liquid Fertilizer Spraying Performance Using A Knapsack Power Sprayer On Soybean Field

    NASA Astrophysics Data System (ADS)

    Gatot, P.; Anang, R.

    2018-05-01

    An effort for increasing soybean production can be conducted by applying liquid fertilizer on soybean cultivation field. The objective of this research was to determine liquid fertilizer spraying performance using knapsack power sprayer TASCO TF-900 on a soybean cultivation field. Performances test were conducted in the Laboratory of Spraying Test and on a soybean cultivation field to determine (1) effective spraying width, (2) droplets diameter, (3) droplets density, (4) effective spraying discharge rate, and (5) effective field capacity of spraying. The research was conducted using 2 methods: (1) one-nozzle spraying, and (2) four- nozzles spraying. Results of the research showed that at a constant pressure of 900 kPa effective spraying width using one-nozzle spraying and four-nozzles spraying were 0.62 m and 1.10 m. A bigger effective spraying width was resulted in a bigger average effective spraying discharge rate and average effective spraying field capacity of 4.52 l/min and 83.92 m2/min on forward walking speed range of 0.94 m/s up to 1.77 m/s. On the contrary, bigger effective spraying width was result in bigger droplets diameter of 502.73 μm and a smaller droplets density of 98.39 droplets/cm2, whereas smaller effective spraying width was resulted in a smaller droplets diameter of 367.09 μm and a bigger droplets density of 350.53 droplets/cm2. One-nozzle spraying method produced a better spraying quality than four-nozzles spraying method, although four-nozzles spraying was resulted in a bigger effective field capacity of spraying.

  8. Tsunami Simulation Method Assimilating Ocean Bottom Pressure Data Near a Tsunami Source Region

    NASA Astrophysics Data System (ADS)

    Tanioka, Yuichiro

    2018-02-01

    A new method was developed to reproduce the tsunami height distribution in and around the source area, at a certain time, from a large number of ocean bottom pressure sensors, without information on an earthquake source. A dense cabled observation network called S-NET, which consists of 150 ocean bottom pressure sensors, was installed recently along a wide portion of the seafloor off Kanto, Tohoku, and Hokkaido in Japan. However, in the source area, the ocean bottom pressure sensors cannot observe directly an initial ocean surface displacement. Therefore, we developed the new method. The method was tested and functioned well for a synthetic tsunami from a simple rectangular fault with an ocean bottom pressure sensor network using 10 arc-min, or 20 km, intervals. For a test case that is more realistic, ocean bottom pressure sensors with 15 arc-min intervals along the north-south direction and sensors with 30 arc-min intervals along the east-west direction were used. In the test case, the method also functioned well enough to reproduce the tsunami height field in general. These results indicated that the method could be used for tsunami early warning by estimating the tsunami height field just after a great earthquake without the need for earthquake source information.

  9. The use of computed radiography plates to determine light and radiation field coincidence.

    PubMed

    Kerns, James R; Anand, Aman

    2013-11-01

    Photo-stimulable phosphor computed radiography (CR) has characteristics that allow the output to be manipulated by both radiation and optical light. The authors have developed a method that uses these characteristics to carry out radiation field and light field coincidence quality assurance on linear accelerators. CR detectors from Kodak were used outside their cassettes to measure both radiation and light field edges from a Varian linear accelerator. The CR detector was first exposed to a radiation field and then to a slightly smaller light field. The light impinged on the detector's latent image, removing to an extent the portion exposed to the light field. The detector was then digitally scanned. A MATLAB-based algorithm was developed to automatically analyze the images and determine the edges of the light and radiation fields, the vector between the field centers, and the crosshair center. Radiographic film was also used as a control to confirm the radiation field size. Analysis showed a high degree of repeatability with the proposed method. Results between the proposed method and radiographic film showed excellent agreement of the radiation field. The effect of varying monitor units and light exposure time was tested and found to be very small. Radiation and light field sizes were determined with an uncertainty of less than 1 mm, and light and crosshair centers were determined within 0.1 mm. A new method was developed to digitally determine the radiation and light field size using CR photo-stimulable phosphor plates. The method is quick and reproducible, allowing for the streamlined and robust assessment of light and radiation field coincidence, with no observer interpretation needed.

  10. Continuous improvement of medical test reliability using reference methods and matrix-corrected target values in proficiency testing schemes: application to glucose assay.

    PubMed

    Delatour, Vincent; Lalere, Beatrice; Saint-Albin, Karène; Peignaux, Maryline; Hattchouel, Jean-Marc; Dumont, Gilles; De Graeve, Jacques; Vaslin-Reimann, Sophie; Gillery, Philippe

    2012-11-20

    The reliability of biological tests is a major issue for patient care in terms of public health that involves high economic stakes. Reference methods, as well as regular external quality assessment schemes (EQAS), are needed to monitor the analytical performance of field methods. However, control material commutability is a major concern to assess method accuracy. To overcome material non-commutability, we investigated the possibility of using lyophilized serum samples together with a limited number of frozen serum samples to assign matrix-corrected target values, taking the example of glucose assays. Trueness of the current glucose assays was first measured against a primary reference method by using human frozen sera. Methods using hexokinase and glucose oxidase with spectroreflectometric detection proved very accurate, with bias ranging between -2.2% and +2.3%. Bias of methods using glucose oxidase with spectrophotometric detection was +4.5%. Matrix-related bias of the lyophilized materials was then determined and ranged from +2.5% to -14.4%. Matrix-corrected target values were assigned and used to assess trueness of 22 sub-peer groups. We demonstrated that matrix-corrected target values can be a valuable tool to assess field method accuracy in large scale surveys where commutable materials are not available in sufficient amount with acceptable costs. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. A simple field kit for the determination of drug susceptibility in Plasmodium falciparum.

    PubMed

    Nguyen-Dinh, P; Magloire, R; Chin, W

    1983-05-01

    A field kit has been developed which greatly simplifies the performance of the 48-hour in vitro test for drug resistance in Plasmodium falciparum. The kit uses an easily reconstituted lyophilized culture medium, and requires only a fingerprick blood sample. In parallel tests with 13 isolates of P. falciparum in Haiti, the new technique had a success rate equal to that of the previously described method, with comparable results in terms of parasite susceptibility in vitro to chloroquine and pyrimethamine.

  12. METHOD OF TESTING THERMAL NEUTRON FISSIONABLE MATERIAL FOR PURITY

    DOEpatents

    Fermi, E.; Anderson, H.L.

    1961-01-24

    A process is given for determining the neutronic purity of fissionable material by the so-called shotgun test. The effect of a standard neutron absorber of known characteristics and amounts on a neutronic field also of known characteristics is measured and compared with the effect which the impurities derived from a known quantity of fissionable material has on the same neutronic field. The two readings are then made the basis of calculation from which the amount of impurities can be computed.

  13. Performance Evaluation of "Low-cost" Sensors for Measuring Gaseous and Particle Air Pollutants: Results from Two Years of Field and Laboratory Testing

    NASA Astrophysics Data System (ADS)

    Feenstra, B. J.; Polidori, A.; Tisopulos, L.; Papapostolou, V.; Zhang, H.; Pathmanabhan, J.

    2016-12-01

    In recent years great progress has been made in development of low-cost miniature air quality sensing technologies. Such low-cost sensors offer a prospect of providing a real-time spatially dense information on pollutants, however, the quality of the data produced by these sensors is so far untested. In an effort to inform the general public about the actual performance of commercially available low-cost air quality sensors, in June 2014 the South Coast Air Quality Management District (SCAQMD) has established the Air Quality Sensor Performance Evaluation Center (AQ-SPEC). This program performs a thorough characterization of low-cost sensors under ambient (in the field) and controlled (in the laboratory) conditions. During the field testing, air quality sensors are operated side-by-side with Federal Reference Methods and Federal Equivalent Methods (FRM and FEM, respectively), which are routinely used to measure the ambient concentration of gaseous or particle pollutants for regulatory purposes. Field testing is conducted at two of SCAQMD's existing air monitoring stations, one in Rubidoux and one near the I-710 freeway. Sensors that demonstrate an acceptable performance in the field are brought back to the lab where a "characterization chamber" is used to challenge these devices with known concentrations of different particle and gaseous pollutants under different temperature and relative humidity levels. Testing results for each sensor are then summarized in a technical report and, along with other relevant information, posted online on a dedicated website (www.aqmd.gov/aq-spec) to educate the public about the capabilities of commercially available sensors and their potential applications. During this presentation, the results from two years of field and laboratory testing will be presented. The major strengths and weaknesses of some of the most commonly available particle and gaseous sensors will be discussed.

  14. Accuracy Test of the OPLS-AA Force Field for Calculating Free Energies of Mixing and Comparison with PAC-MAC

    PubMed Central

    2017-01-01

    We have calculated the excess free energy of mixing of 1053 binary mixtures with the OPLS-AA force field using two different methods: thermodynamic integration (TI) of molecular dynamics simulations and the Pair Configuration to Molecular Activity Coefficient (PAC-MAC) method. PAC-MAC is a force field based quasi-chemical method for predicting miscibility properties of various binary mixtures. The TI calculations yield a root mean squared error (RMSE) compared to experimental data of 0.132 kBT (0.37 kJ/mol). PAC-MAC shows a RMSE of 0.151 kBT with a calculation speed being potentially 1.0 × 104 times greater than TI. OPLS-AA force field parameters are optimized using PAC-MAC based on vapor–liquid equilibrium data, instead of enthalpies of vaporization or densities. The RMSE of PAC-MAC is reduced to 0.099 kBT by optimizing 50 force field parameters. The resulting OPLS-PM force field has a comparable accuracy as the OPLS-AA force field in the calculation of mixing free energies using TI. PMID:28418655

  15. A multiwave range test for obstacle reconstructions with unknown physical properties

    NASA Astrophysics Data System (ADS)

    Potthast, Roland; Schulz, Jochen

    2007-08-01

    We develop a new multiwave version of the range test for shape reconstruction in inverse scattering theory. The range test [R. Potthast, et al., A `range test' for determining scatterers with unknown physical properties, Inverse Problems 19(3) (2003) 533-547] has originally been proposed to obtain knowledge about an unknown scatterer when the far field pattern for only one plane wave is given. Here, we extend the method to the case of multiple waves and show that the full shape of the unknown scatterer can be reconstructed. We further will clarify the relation between the range test methods, the potential method [A. Kirsch, R. Kress, On an integral equation of the first kind in inverse acoustic scattering, in: Inverse Problems (Oberwolfach, 1986), Internationale Schriftenreihe zur Numerischen Mathematik, vol. 77, Birkhauser, Basel, 1986, pp. 93-102] and the singular sources method [R. Potthast, Point sources and multipoles in inverse scattering theory, Habilitation Thesis, Gottingen, 1999]. In particular, we propose a new version of the Kirsch-Kress method using the range test and a new approach to the singular sources method based on the range test and potential method. Numerical examples of reconstructions for all four methods are provided.

  16. Selective solvent-free chromium detection using cadmium-free quantum dots

    NASA Astrophysics Data System (ADS)

    Meylemans, Heather A.; Baca, Alfred J.; Cambrea, Lee R.; Ostrom, Gregory S.

    2017-07-01

    Currently, the method of choice to test for the presence of chromium in water is to submit samples to a lab for testing. We present a simple field-ready test that is selective for the presence of chromium at concentrations of 100 ppb or greater. The Environmental Protection Agency maximum contaminant level (MCL) for total chromium is 100 ppb. This test uses a simple on/off fluorescent screening employing the use of silver indium sulfide (AgInS2) quantum dots (QDs). These QDs were impregnated into cotton pads to simplify field testing without the need for solvents or other liquid chemicals to be present. The change in fluorescence is instant and can be readily observed by eye with the use of a UV flashlight.

  17. Magnetic Field Monitoring in the SNS and LANL Neutron EDM Experiments

    NASA Astrophysics Data System (ADS)

    Aleksandrova, Alina; SNS nEDM Collaboration; LANL nEDM Collaboration

    2017-09-01

    The SNS neutron EDM experiment requires the ability to precisely control and monitor the magnetic field inside of the fiducial volume. However, it is not always practical (or even possible) to measure the field within the region of interest directly. To remedy this issue, we have designed a field monitoring system that will allow us to reconstruct the field inside of the fiducial volume using noninvasive measurements of the field components at discrete locations external to this volume. A prototype probe array (consisting of 12 single-axis fluxgate magnetometer sensors) was used to monitor the magnetic field within the fiducial volume of an in-house magnetic testing apparatus. In this talk, the design and results of this test will be presented, and the possible implementation of this field monitoring method may have in the room temperature LANL neutron EDM experiment will be discussed. This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics, under Award Number DE-SC-0014622.

  18. Comparative Validation of Five Quantitative Rapid Test Kits for the Analysis of Salt Iodine Content: Laboratory Performance, User- and Field-Friendliness

    PubMed Central

    Rohner, Fabian; Kangambèga, Marcelline O.; Khan, Noor; Kargougou, Robert; Garnier, Denis; Sanou, Ibrahima; Ouaro, Bertine D.; Petry, Nicolai; Wirth, James P.; Jooste, Pieter

    2015-01-01

    Background Iodine deficiency has important health and development consequences and the introduction of iodized salt as national programs has been a great public health success in the past decades. To render national salt iodization programs sustainable and ensure adequate iodization levels, simple methods to quantitatively assess whether salt is adequately iodized are required. Several methods claim to be simple and reliable, and are available on the market or are in development. Objective This work has validated the currently available quantitative rapid test kits (quantRTK) in a comparative manner for both their laboratory performance and ease of use in field settings. Methods Laboratory performance parameters (linearity, detection and quantification limit, intra- and inter-assay imprecision) were conducted on 5 quantRTK. We assessed inter-operator imprecision using salt of different quality along with the comparison of 59 salt samples from across the globe; measurements were made both in a laboratory and a field setting by technicians and non-technicians. Results from the quantRTK were compared against iodometric titration for validity. An ‘ease-of-use’ rating system was developed to identify the most suitable quantRTK for a given task. Results Most of the devices showed acceptable laboratory performance, but for some of the devices, use by non-technicians revealed poorer performance when working in a routine manner. Of the quantRTK tested, the iCheck® and I-Reader® showed most consistent performance and ease of use, and a newly developed paper-based method (saltPAD) holds promise if further developed. Conclusions User- and field-friendly devices are now available and the most appropriate quantRTK can be selected depending on the number of samples and the budget available. PMID:26401655

  19. An Optimal Deconvolution Method for Reconstructing Pneumatically Distorted Near-Field Sonic Boom Pressure Measurements

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Haering, Edward A., Jr.; Ehernberger, L. J.

    1996-01-01

    In-flight measurements of the SR-71 near-field sonic boom were obtained by an F-16XL airplane at flightpath separation distances from 40 to 740 ft. Twenty-two signatures were obtained from Mach 1.60 to Mach 1.84 and altitudes from 47,600 to 49,150 ft. The shock wave signatures were measured by the total and static sensors on the F-16XL noseboo. These near-field signature measurements were distorted by pneumatic attenuation in the pitot-static sensors and accounting for their effects using optimal deconvolution. Measurement system magnitude and phase characteristics were determined from ground-based step-response tests and extrapolated to flight conditions using analytical models. Deconvolution was implemented using Fourier transform methods. Comparisons of the shock wave signatures reconstructed from the total and static pressure data are presented. The good agreement achieved gives confidence of the quality of the reconstruction analysis. although originally developed to reconstruct the sonic boom signatures from SR-71 sonic boom flight tests, the methods presented here generally apply to other types of highly attenuated or distorted pneumatic measurements.

  20. rf breakdown tests of mm-wave metallic accelerating structures

    DOE PAGES

    Dal Forno, Massimo; Dolgashev, Valery; Bowden, Gordon; ...

    2016-01-06

    In this study, we explore the physics and frequency-scaling of vacuum rf breakdowns at sub-THz frequencies. We present the experimental results of rf tests performed in metallic mm-wave accelerating structures. These experiments were carried out at the facility for advanced accelerator experimental tests (FACET) at the SLAC National Accelerator Laboratory. The rf fields were excited by the FACET ultrarelativistic electron beam. We compared the performances of metal structures made with copper and stainless steel. The rf frequency of the fundamental accelerating mode, propagating in the structures at the speed of light, varies from 115 to 140 GHz. The traveling wavemore » structures are 0.1 m long and composed of 125 coupled cavities each. We determined the peak electric field and pulse length where the structures were not damaged by rf breakdowns. We calculated the electric and magnetic field correlated with the rf breakdowns using the FACET bunch parameters. The wakefields were calculated by a frequency domain method using periodic eigensolutions. Such a method takes into account wall losses and is applicable to a large variety of geometries. The maximum achieved accelerating gradient is 0.3 GV/m with a peak surface electric field of 1.5 GV/m and a pulse length of about 2.4 ns.« less

  1. In vitro assessment of the immunity of implantable cardioverter-defibrillators to magnetic fields of 50/60 Hz.

    PubMed

    Katrib, J; Nadi, M; Kourtiche, D; Magne, I; Schmitt, P; Souques, M; Roth, P

    2013-10-01

    Public concern for the compatibility of electromagnetic (EM) sources with active implantable medical devices (AIMD) has prompted the development of new systems that can perform accurate exposure studies. EM field interference with active cardiac implants (e.g. implantable cardioverter-defibrillators (ICDs)) can be critical. This paper describes a magnetic field (MF) exposure system and the method developed for testing the immunity of ICD to continuous-wave MFs. The MFs were created by Helmholtz coils, housed in a Faraday cage. The coils were able to produce highly uniform MFs up to 4000 µT at 50 Hz and 3900 µT at 60 Hz, within the test space. Four ICDs were tested. No dysfunctions were found in the generated MFs. These results confirm that the tested ICDs were immune to low frequency MFs.

  2. External Magnetic Field Reduction Techniques for the Advanced Stirling Radioisotope Generator

    NASA Technical Reports Server (NTRS)

    Niedra, Janis M.; Geng, Steven M.

    2013-01-01

    Linear alternators coupled to high efficiency Stirling engines are strong candidates for thermal-to-electric power conversion in space. However, the magnetic field emissions, both AC and DC, of these permanent magnet excited alternators can interfere with sensitive instrumentation onboard a spacecraft. Effective methods to mitigate the AC and DC electromagnetic interference (EMI) from solenoidal type linear alternators (like that used in the Advanced Stirling Convertor) have been developed for potential use in the Advanced Stirling Radioisotope Generator. The methods developed avoid the complexity and extra mass inherent in data extraction from multiple sensors or the use of shielding. This paper discusses these methods, and also provides experimental data obtained during breadboard testing of both AC and DC external magnetic field devices.

  3. SIMPLIFIED PRACTICAL TEST METHOD FOR PORTABLE DOSE METERS USING SEVERAL SEALED RADIOACTIVE SOURCES.

    PubMed

    Mikamoto, Takahiro; Yamada, Takahiro; Kurosawa, Tadahiro

    2016-09-01

    Sealed radioactive sources which have small activity were employed for the determination of response and tests for non-linearity and energy dependence of detector responses. Close source-to-detector geometry (at 0.3 m or less) was employed to practical tests for portable dose meters to accumulate statistically sufficient ionizing currents. Difference between response in the present experimentally studied field and in the reference field complied with ISO 4037 due to non-uniformity of radiation fluence at close geometry was corrected by use of Monte Carlo simulation. As a consequence, corrected results were consistent with the results obtained in the ISO 4037 reference field within their uncertainties. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. New Computational Methods for the Prediction and Analysis of Helicopter Noise

    NASA Technical Reports Server (NTRS)

    Strawn, Roger C.; Oliker, Leonid; Biswas, Rupak

    1996-01-01

    This paper describes several new methods to predict and analyze rotorcraft noise. These methods are: 1) a combined computational fluid dynamics and Kirchhoff scheme for far-field noise predictions, 2) parallel computer implementation of the Kirchhoff integrations, 3) audio and visual rendering of the computed acoustic predictions over large far-field regions, and 4) acoustic tracebacks to the Kirchhoff surface to pinpoint the sources of the rotor noise. The paper describes each method and presents sample results for three test cases. The first case consists of in-plane high-speed impulsive noise and the other two cases show idealized parallel and oblique blade-vortex interactions. The computed results show good agreement with available experimental data but convey much more information about the far-field noise propagation. When taken together, these new analysis methods exploit the power of new computer technologies and offer the potential to significantly improve our prediction and understanding of rotorcraft noise.

  5. Comparison of five methods of malaria detection in the outpatient setting.

    PubMed

    Lema, O E; Carter, J Y; Nagelkerke, N; Wangai, M W; Kitenge, P; Gikunda, S M; Arube, P A; Munafu, C G; Materu, S F; Adhiambo, C A; Mukunza, H K

    1999-02-01

    In eastern Africa where 90% of the malaria is due to Plasmodium falciparum, the accuracy of malaria diagnosis at the outpatient level is becoming increasingly important due to problems of drug resistance and use of alternative, costly antimalarial drugs. The quantitative buffy coat (QBC) technique, acridine orange staining with an interference filter system, and the ParaSight-F test have been introduced as alternative methods to conventional microscopy for the diagnosis of malaria. Two hundred thirteen outpatients were tested using these alternative methods and conventional microscopy by five experienced technologists; two were randomly allocated to read the results of each test. Paired results showed the highest level of agreement with the ParaSight-F test (99%), followed by Field stain (92%). The results of the QBC technique showed the least agreement (73%). Using conventional microscopy as the reference standard, the ParaSight-F test had a sensitivity range of 90-92% and a specificity of 99%, staining with acridine orange had a sensitivity range of 77-96% and a specificity range of 81-98% and the QBC technique had a sensitivity range of 88-98% and a specificity range of 58-90%. All microscopic tests showed lower sensitivities (as low as 20% using staining with acridine orange) in detecting low parasitemias (< or = 320/microl) than the ParaSight-F test (70%). Due to the high cost of the ParaSight-F test, Field-stained blood films remain the most appropriate method for diagnosis of P. falciparum in eastern Africa. The ParaSight-F test may be used in situations where no trained microscopists are available, or where malaria is strongly suspected and the results of microscopy are negative.

  6. Modelling the Velocity Field in a Regular Grid in the Area of Poland on the Basis of the Velocities of European Permanent Stations

    NASA Astrophysics Data System (ADS)

    Bogusz, Janusz; Kłos, Anna; Grzempowski, Piotr; Kontny, Bernard

    2014-06-01

    The paper presents the results of testing the various methods of permanent stations' velocity residua interpolation in a regular grid, which constitutes a continuous model of the velocity field in the territory of Poland. Three packages of software were used in the research from the point of view of interpolation: GMT ( The Generic Mapping Tools), Surfer and ArcGIS. The following methods were tested in the softwares: the Nearest Neighbor, Triangulation (TIN), Spline Interpolation, Surface, Inverse Distance to a Power, Minimum Curvature and Kriging. The presented research used the absolute velocities' values expressed in the ITRF2005 reference frame and the intraplate velocities related to the NUVEL model of over 300 permanent reference stations of the EPN and ASG-EUPOS networks covering the area of Europe. Interpolation for the area of Poland was done using data from the whole area of Europe to make the results at the borders of the interpolation area reliable. As a result of this research, an optimum method of such data interpolation was developed. All the mentioned methods were tested for being local or global, for the possibility to compute errors of the interpolated values, for explicitness and fidelity of the interpolation functions or the smoothing mode. In the authors' opinion, the best data interpolation method is Kriging with the linear semivariogram model run in the Surfer programme because it allows for the computation of errors in the interpolated values and it is a global method (it distorts the results in the least way). Alternately, it is acceptable to use the Minimum Curvature method. Empirical analysis of the interpolation results obtained by means of the two methods showed that the results are identical. The tests were conducted using the intraplate velocities of the European sites. Statistics in the form of computing the minimum, maximum and mean values of the interpolated North and East components of the velocity residuum were prepared for all the tested methods, and each of the resulting continuous velocity fields was visualized by means of the GMT programme. The interpolated components of the velocities and their residua are presented in the form of tables and bar diagrams.

  7. Generic Verification Protocol for Testing Pesticide Application Spray Drift Reduction Technologies for Row and Field Crops

    EPA Pesticide Factsheets

    This generic verification protocol provides a detailed method to conduct and report results from a verification test of pesticide application technologies that can be used to evaluate these technologies for their potential to reduce spray drift.

  8. A Robust Strategy for Total Ionizing Dose Testing of Field Programmable Gate Arrays

    NASA Technical Reports Server (NTRS)

    Wilcox, Edward; Berg, Melanie; Friendlich, Mark; Lakeman, Joseph; KIm, Hak; Pellish, Jonathan; LaBel, Kenneth

    2012-01-01

    We present a novel method of FPGA TID testing that measures propagation delay between flip-flops operating at maximum speed. Measurement is performed on-chip at-speed and provides a key design metric when building system-critical synchronous designs.

  9. Nondestructive testing and characterization of residual stress field using an ultrasonic method

    NASA Astrophysics Data System (ADS)

    Song, Wentao; Xu, Chunguang; Pan, Qinxue; Song, Jianfeng

    2016-03-01

    To address the difficulty in testing and calibrating the stress gradient in the depth direction of mechanical components, a new technology of nondestructive testing and characterization of the residual stress gradient field by ultrasonic method is proposed based on acoustoelasticity theory. By carrying out theoretical analysis, the sensitivity coefficients of different types of ultrasonic are obtained by taking the low carbon steel(12%C) as a research object. By fixing the interval distance between sending and receiving transducers, the mathematical expressions of the change of stress and the variation of time are established. To design one sending-one receiving and oblique incidence ultrasonic detection probes, according to Snell law, the critically refracted longitudinal wave (LCR wave) is excited at a certain depth of the fixed distance of the tested components. Then, the relationship between the depth of LCR wave detection and the center frequency of the probe in Q235 steel is obtained through experimental study. To detect the stress gradient in the depth direction, a stress gradient LCR wave detection model is established, through which the stress gradient formula is derived by the relationship between center frequency and detecting depth. A C-shaped stress specimen of Q235 steel is designed to conduct stress loading tests, and the stress is measured with the five group probes at different center frequencies. The accuracy of ultrasonic testing is verified by X-ray stress analyzer. The stress value of each specific depth is calculated using the stress gradient formula. Accordingly, the ultrasonic characterization of residual stress field is realized. Characterization results show that the stress gradient distribution is consistent with the simulation in ANSYS. The new technology can be widely applied in the detection of the residual stress gradient field caused by mechanical processing, such as welding and shot peening.

  10. Optimizing household survey methods to monitor the Sustainable Development Goals targets 6.1 and 6.2 on drinking water, sanitation and hygiene: A mixed-methods field-test in Belize

    PubMed Central

    Bain, Robert E. S.; Lunze, Karsten; Unalan, Turgay; Beshanski-Pedersen, Bo; Slaymaker, Tom; Johnston, Richard; Hancioglu, Attila

    2017-01-01

    Background The Sustainable Development Goals (SDGs) require household survey programmes such as the UNICEF-supported Multiple Indicator Cluster Surveys (MICS) to enhance data collection to cover new indicators. This study aims to evaluated methods for assessing water quality, water availability, emptying of sanitation facilities, menstrual hygiene management and the acceptability of water quality testing in households which are key to monitoring SDG targets 6.1 and 6.2 on drinking Water, Sanitation and Hygiene (WASH) and emerging issues. Methods As part of a MICS field test, we interviewed 429 households and 267 women age 15–49 in Stann Creek, Belize in a split-sample experiment. In a concurrent qualitative component, we conducted focus groups with interviewers and cognitive interviews with respondents during and immediately following questionnaire administration in the field to explore their question comprehension and response processes. Findings About 88% of respondents agreed to water quality testing but also desired test results, given the potential implications for their own health. Escherichia coli was present in 36% of drinking water collected at the source, and in 47% of samples consumed in the household. Both questions on water availability necessitated probing by interviewers. About one quarter of households reported emptying of pit latrines and septic tanks, though one-quarter could not provide an answer to the question. Asking questions on menstrual hygiene was acceptable to respondents, but required some clarification and probing. Conclusions In the context of Belize, this study confirmed the feasibility of collecting information on the availability and quality of drinking water, emptying of sanitation facilities and menstrual hygiene in a multi-purpose household survey, indicating specific areas to improve question formulation and field protocols. Improvements have been incorporated into the latest round of MICS surveys which will be a major source of national data for monitoring of SDG targets for drinking water, sanitation and hygiene and emerging issues for WASH sector programming. PMID:29216244

  11. Low-cost extrapolation method for maximal LTE radio base station exposure estimation: test and validation.

    PubMed

    Verloock, Leen; Joseph, Wout; Gati, Azeddine; Varsier, Nadège; Flach, Björn; Wiart, Joe; Martens, Luc

    2013-06-01

    An experimental validation of a low-cost method for extrapolation and estimation of the maximal electromagnetic-field exposure from long-term evolution (LTE) radio base station installations are presented. No knowledge on downlink band occupation or service characteristics is required for the low-cost method. The method is applicable in situ. It only requires a basic spectrum analyser with appropriate field probes without the need of expensive dedicated LTE decoders. The method is validated both in laboratory and in situ, for a single-input single-output antenna LTE system and a 2×2 multiple-input multiple-output system, with low deviations in comparison with signals measured using dedicated LTE decoders.

  12. Meta-analysis of correlations revisited: attempted replication and extension of Field's (2001) simulation studies.

    PubMed

    Hafdahl, Adam R; Williams, Michelle A

    2009-03-01

    In 2 Monte Carlo studies of fixed- and random-effects meta-analysis for correlations, A. P. Field (2001) ostensibly evaluated Hedges-Olkin-Vevea Fisher-z and Schmidt-Hunter Pearson-r estimators and tests in 120 conditions. Some authors have cited those results as evidence not to meta-analyze Fisher-z correlations, especially with heterogeneous correlation parameters. The present attempt to replicate Field's simulations included comparisons with analytic values as well as results for efficiency and confidence-interval coverage. Field's results under homogeneity were mostly replicable, but those under heterogeneity were not: The latter exhibited up to over .17 more bias than ours and, for tests of the mean correlation and homogeneity, respectively, nonnull rejection rates up to .60 lower and .65 higher. Changes to Field's observations and conclusions are recommended, and practical guidance is offered regarding simulation evidence and choices among methods. Most cautions about poor performance of Fisher-z methods are largely unfounded, especially with a more appropriate z-to-r transformation. The Appendix gives a computer program for obtaining Pearson-r moments from a normal Fisher-z distribution, which is used to demonstrate distortion due to direct z-to-r transformation of a mean Fisher-z correlation.

  13. Thermo-magneto-elastoplastic coupling model of metal magnetic memory testing method for ferromagnetic materials

    NASA Astrophysics Data System (ADS)

    Shi, Pengpeng; Zhang, Pengcheng; Jin, Ke; Chen, Zhenmao; Zheng, Xiaojing

    2018-04-01

    Metal magnetic memory (MMM) testing (also known as micro-magnetic testing) is a new non-destructive electromagnetic testing method that can diagnose ferromagnetic materials at an early stage by measuring the MMM signal directly on the material surface. Previous experiments have shown that many factors affect MMM signals, in particular, the temperature, the elastoplastic state, and the complex environmental magnetic field. However, the fact that there have been only a few studies of either how these factors affect the signals or the physical coupling mechanisms among them seriously limits the industrial applications of MMM testing. In this paper, a nonlinear constitutive relation for a ferromagnetic material considering the influences of temperature and elastoplastic state is established under a weak magnetic field and is used to establish a nonlinear thermo-magneto-elastoplastic coupling model of MMM testing. Comparing with experimental data verifies that the proposed theoretical model can accurately describe the thermo-magneto-elastoplastic coupling influence on MMM signals. The proposed theoretical model can predict the MMM signals in a complex environment and so is expected to provide a theoretical basis for improving the degree of quantification in MMM testing.

  14. Clinical applications of breath testing

    PubMed Central

    Paschke, Kelly M; Mashir, Alquam

    2010-01-01

    Breath testing has the potential to benefit the medical field as a cost-effective, non-invasive diagnostic tool for diseases of the lung and beyond. With growing evidence of clinical worth, standardization of methods, and new sensor and detection technologies the stage is set for breath testing to gain considerable attention and wider application in upcoming years. PMID:21173863

  15. The PneuCarriage Project: A Multi-Centre Comparative Study to Identify the Best Serotyping Methods for Examining Pneumococcal Carriage in Vaccine Evaluation Studies

    PubMed Central

    Satzke, Catherine; Dunne, Eileen M.; Porter, Barbara D.; Klugman, Keith P.; Mulholland, E. Kim

    2015-01-01

    Background The pneumococcus is a diverse pathogen whose primary niche is the nasopharynx. Over 90 different serotypes exist, and nasopharyngeal carriage of multiple serotypes is common. Understanding pneumococcal carriage is essential for evaluating the impact of pneumococcal vaccines. Traditional serotyping methods are cumbersome and insufficient for detecting multiple serotype carriage, and there are few data comparing the new methods that have been developed over the past decade. We established the PneuCarriage project, a large, international multi-centre study dedicated to the identification of the best pneumococcal serotyping methods for carriage studies. Methods and Findings Reference sample sets were distributed to 15 research groups for blinded testing. Twenty pneumococcal serotyping methods were used to test 81 laboratory-prepared (spiked) samples. The five top-performing methods were used to test 260 nasopharyngeal (field) samples collected from children in six high-burden countries. Sensitivity and positive predictive value (PPV) were determined for the test methods and the reference method (traditional serotyping of >100 colonies from each sample). For the alternate serotyping methods, the overall sensitivity ranged from 1% to 99% (reference method 98%), and PPV from 8% to 100% (reference method 100%), when testing the spiked samples. Fifteen methods had ≥70% sensitivity to detect the dominant (major) serotype, whilst only eight methods had ≥70% sensitivity to detect minor serotypes. For the field samples, the overall sensitivity ranged from 74.2% to 95.8% (reference method 93.8%), and PPV from 82.2% to 96.4% (reference method 99.6%). The microarray had the highest sensitivity (95.8%) and high PPV (93.7%). The major limitation of this study is that not all of the available alternative serotyping methods were included. Conclusions Most methods were able to detect the dominant serotype in a sample, but many performed poorly in detecting the minor serotype populations. Microarray with a culture amplification step was the top-performing method. Results from this comprehensive evaluation will inform future vaccine evaluation and impact studies, particularly in low-income settings, where pneumococcal disease burden remains high. PMID:26575033

  16. Preparation of construction specifications, contract documents, field testing, educational materials, and course offerings for trenchless construction

    DOT National Transportation Integrated Search

    2005-10-01

    Trenchless technology offers methods by which underground utilities may be installed without damage to overlying pavement, if proper precautions are observed. In the past ten years, repeated improvements in technology, materials, and methods have adv...

  17. Detection of antibodies to egg drop syndrome virus in chicken serum using a field-based immunofiltration (flow-through) test.

    PubMed

    Raj, G Dhinakar; Thiagarajan, V; Nachimuthu, K

    2007-09-01

    A simple, user-friendly, and rapid method to detect the presence of antibodies to egg drop syndrome 76 (EDS) virus in chicken sera based on an immunofiltration (flow-through) test was developed. Purified EDS virus antigen was coated onto nitrocellulose membranes housed in a plastic module with layers of absorbent filter pads underneath. Following addition of serum to be tested and washing, monoclonal antibodies or polyclonal serum to chicken immunoglobulin G (IgG) was used as a bridge antibody to mediate binding between EDS virus-specific IgG and protein A gold conjugate. The appearance of a pink dot indicated the presence of antibodies to EDS virus in the sample tested. The results could be obtained within 5-10 min. The developed immunofiltration test could detect antibodies in the sera of experimentally vaccinated chickens from 2 wk postvaccination. With field sera samples, this test was positive in samples having hemagglutination inhibition titers of 8 and above. This test has the potential to be used as a field-based kit to assess seroconversion in EDS-vaccinated flocks.

  18. Lessons learned in preparing method 29 filters for compliance testing audits.

    PubMed

    Martz, R F; McCartney, J E; Bursey, J T; Riley, C E

    2000-01-01

    Companies conducting compliance testing are required to analyze audit samples at the time they collect and analyze the stack samples if audit samples are available. Eastern Research Group (ERG) provides technical support to the EPA's Emission Measurements Center's Stationary Source Audit Program (SSAP) for developing, preparing, and distributing performance evaluation samples and audit materials. These audit samples are requested via the regulatory Agency and include spiked audit materials for EPA Method 29-Metals Emissions from Stationary Sources, as well as other methods. To provide appropriate audit materials to federal, state, tribal, and local governments, as well as agencies performing environmental activities and conducting emission compliance tests, ERG has recently performed testing of blank filter materials and preparation of spiked filters for EPA Method 29. For sampling stationary sources using an EPA Method 29 sampling train, the use of filters without organic binders containing less than 1.3 microg/in.2 of each of the metals to be measured is required. Risk Assessment testing imposes even stricter requirements for clean filter background levels. Three vendor sources of quartz fiber filters were evaluated for background contamination to ensure that audit samples would be prepared using filters with the lowest metal background levels. A procedure was developed to test new filters, and a cleaning procedure was evaluated to see if a greater level of cleanliness could be achieved using an acid rinse with new filters. Background levels for filters supplied by different vendors and within lots of filters from the same vendor showed a wide variation, confirmed through contact with several analytical laboratories that frequently perform EPA Method 29 analyses. It has been necessary to repeat more than one compliance test because of suspect metals background contamination levels. An acid cleaning step produced improvement in contamination level, but the difference was not significant for most of the Method 29 target metals. As a result of our studies, we conclude: Filters for Method 29 testing should be purchased in lots as large as possible. Testing firms should pre-screen new boxes and/or new lots of filters used for Method 29 testing. Random analysis of three filters (top, middle, bottom of the box) from a new box of vendor filters before allowing them to be used in field tests is a prudent approach. A box of filters from a given vendor should be screened, and filters from this screened box should be used both for testing and as field blanks in each test scenario to provide the level of quality assurance required for stationary source testing.

  19. Teaching Hearing-Impaired Children in Iraq Using a New Teaching Method.

    ERIC Educational Resources Information Center

    Harris, N. D. C.; Mustafa, N.

    1986-01-01

    Describes a field test and results of a new didactic teaching method involving resource-based learning to teach various aspects of mathematics and science (fractions, magnetism, planets) to elementary aged hearing impaired student in Iraq. The dramatic improvements in language for learners is described and implications of the methods are…

  20. THe Case Method of Instruction (CMI) Project. Final Report.

    ERIC Educational Resources Information Center

    McWilliam, P. J.; And Others

    This final report describes the Case Method of Instruction (CMI) Project, a project to develop, field test, and disseminate training materials to facilitate the use of the Case Method of Instruction by inservice and preservice instructors in developmental disabilities. CMI project activities focused on developing a collection of case stories and…

  1. Field test and sensitivity analysis of a sensible heat balance method to determine ice contents

    USDA-ARS?s Scientific Manuscript database

    Soil ice content impacts winter vadose zone hydrology. It may be possible to estimate changes in soil ice content with a sensible heat balance (SHB) method, using measurements from heat pulse (HP) sensors. Feasibility of the SHB method is unknown because of difficulties in measuring soil thermal pro...

  2. Computation of Relative Magnetic Helicity in Spherical Coordinates

    NASA Astrophysics Data System (ADS)

    Moraitis, Kostas; Pariat, Étienne; Savcheva, Antonia; Valori, Gherardo

    2018-06-01

    Magnetic helicity is a quantity of great importance in solar studies because it is conserved in ideal magnetohydrodynamics. While many methods for computing magnetic helicity in Cartesian finite volumes exist, in spherical coordinates, the natural coordinate system for solar applications, helicity is only treated approximately. We present here a method for properly computing the relative magnetic helicity in spherical geometry. The volumes considered are finite, of shell or wedge shape, and the three-dimensional magnetic field is considered to be fully known throughout the studied domain. Testing of the method with well-known, semi-analytic, force-free magnetic-field models reveals that it has excellent accuracy. Further application to a set of nonlinear force-free reconstructions of the magnetic field of solar active regions and comparison with an approximate method used in the past indicates that the proposed method can be significantly more accurate, thus making our method a promising tool in helicity studies that employ spherical geometry. Additionally, we determine and discuss the applicability range of the approximate method.

  3. Prediction of molecular crystal structures by a crystallographic QM/MM model with full space-group symmetry.

    PubMed

    Mörschel, Philipp; Schmidt, Martin U

    2015-01-01

    A crystallographic quantum-mechanical/molecular-mechanical model (c-QM/MM model) with full space-group symmetry has been developed for molecular crystals. The lattice energy was calculated by quantum-mechanical methods for short-range interactions and force-field methods for long-range interactions. The quantum-mechanical calculations covered the interactions within the molecule and the interactions of a reference molecule with each of the surrounding 12-15 molecules. The interactions with all other molecules were treated by force-field methods. In each optimization step the energies in the QM and MM shells were calculated separately as single-point energies; after adding both energy contributions, the crystal structure (including the lattice parameters) was optimized accordingly. The space-group symmetry was maintained throughout. Crystal structures with more than one molecule per asymmetric unit, e.g. structures with Z' = 2, hydrates and solvates, have been optimized as well. Test calculations with different quantum-mechanical methods on nine small organic molecules revealed that the density functional theory methods with dispersion correction using the B97-D functional with 6-31G* basis set in combination with the DREIDING force field reproduced the experimental crystal structures with good accuracy. Subsequently the c-QM/MM method was applied to nine compounds from the CCDC blind tests resulting in good energy rankings and excellent geometric accuracies.

  4. An effective parameter optimization technique for vibration flow field characterization of PP melts via LS-SVM combined with SALS in an electromagnetism dynamic extruder

    NASA Astrophysics Data System (ADS)

    Xian, Guangming

    2018-03-01

    A method for predicting the optimal vibration field parameters by least square support vector machine (LS-SVM) is presented in this paper. One convenient and commonly used technique for characterizing the the vibration flow field of polymer melts films is small angle light scattering (SALS) in a visualized slit die of the electromagnetism dynamic extruder. The optimal value of vibration vibration frequency, vibration amplitude, and the maximum light intensity projection area can be obtained by using LS-SVM for prediction. For illustrating this method and show its validity, the flowing material is used with polypropylene (PP) and fifteen samples are tested at the rotation speed of screw at 36rpm. This paper first describes the apparatus of SALS to perform the experiments, then gives the theoretical basis of this new method, and detail the experimental results for parameter prediction of vibration flow field. It is demonstrated that it is possible to use the method of SALS and obtain detailed information on optimal parameter of vibration flow field of PP melts by LS-SVM.

  5. Magnetic field shift due to mechanical vibration in functional magnetic resonance imaging.

    PubMed

    Foerster, Bernd U; Tomasi, Dardo; Caparelli, Elisabeth C

    2005-11-01

    Mechanical vibrations of the gradient coil system during readout in echo-planar imaging (EPI) can increase the temperature of the gradient system and alter the magnetic field distribution during functional magnetic resonance imaging (fMRI). This effect is enhanced by resonant modes of vibrations and results in apparent motion along the phase encoding direction in fMRI studies. The magnetic field drift was quantified during EPI by monitoring the resonance frequency interleaved with the EPI acquisition, and a novel method is proposed to correct the apparent motion. The knowledge on the frequency drift over time was used to correct the phase of the k-space EPI dataset. Since the resonance frequency changes very slowly over time, two measurements of the resonance frequency, immediately before and after the EPI acquisition, are sufficient to remove the field drift effects from fMRI time series. The frequency drift correction method was tested "in vivo" and compared to the standard image realignment method. The proposed method efficiently corrects spurious motion due to magnetic field drifts during fMRI. (c) 2005 Wiley-Liss, Inc.

  6. The Multidimensional Assessment of Interoceptive Awareness (MAIA)

    PubMed Central

    Mehling, Wolf E.; Price, Cynthia; Daubenmier, Jennifer J.; Acree, Mike; Bartmess, Elizabeth; Stewart, Anita

    2012-01-01

    This paper describes the development of a multidimensional self-report measure of interoceptive body awareness. The systematic mixed-methods process involved reviewing the current literature, specifying a multidimensional conceptual framework, evaluating prior instruments, developing items, and analyzing focus group responses to scale items by instructors and patients of body awareness-enhancing therapies. Following refinement by cognitive testing, items were field-tested in students and instructors of mind-body approaches. Final item selection was achieved by submitting the field test data to an iterative process using multiple validation methods, including exploratory cluster and confirmatory factor analyses, comparison between known groups, and correlations with established measures of related constructs. The resulting 32-item multidimensional instrument assesses eight concepts. The psychometric properties of these final scales suggest that the Multidimensional Assessment of Interoceptive Awareness (MAIA) may serve as a starting point for research and further collaborative refinement. PMID:23133619

  7. Newtonian CAFE: a new ideal MHD code to study the solar atmosphere

    NASA Astrophysics Data System (ADS)

    González-Avilés, J. J.; Cruz-Osorio, A.; Lora-Clavijo, F. D.; Guzmán, F. S.

    2015-12-01

    We present a new code designed to solve the equations of classical ideal magnetohydrodynamics (MHD) in three dimensions, submitted to a constant gravitational field. The purpose of the code centres on the analysis of solar phenomena within the photosphere-corona region. We present 1D and 2D standard tests to demonstrate the quality of the numerical results obtained with our code. As solar tests we present the transverse oscillations of Alfvénic pulses in coronal loops using a 2.5D model, and as 3D tests we present the propagation of impulsively generated MHD-gravity waves and vortices in the solar atmosphere. The code is based on high-resolution shock-capturing methods, uses the Harten-Lax-van Leer-Einfeldt (HLLE) flux formula combined with Minmod, MC, and WENO5 reconstructors. The divergence free magnetic field constraint is controlled using the Flux Constrained Transport method.

  8. Optimizing household survey methods to monitor the Sustainable Development Goals targets 6.1 and 6.2 on drinking water, sanitation and hygiene: A mixed-methods field-test in Belize.

    PubMed

    Khan, Shane M; Bain, Robert E S; Lunze, Karsten; Unalan, Turgay; Beshanski-Pedersen, Bo; Slaymaker, Tom; Johnston, Richard; Hancioglu, Attila

    2017-01-01

    The Sustainable Development Goals (SDGs) require household survey programmes such as the UNICEF-supported Multiple Indicator Cluster Surveys (MICS) to enhance data collection to cover new indicators. This study aims to evaluated methods for assessing water quality, water availability, emptying of sanitation facilities, menstrual hygiene management and the acceptability of water quality testing in households which are key to monitoring SDG targets 6.1 and 6.2 on drinking Water, Sanitation and Hygiene (WASH) and emerging issues. As part of a MICS field test, we interviewed 429 households and 267 women age 15-49 in Stann Creek, Belize in a split-sample experiment. In a concurrent qualitative component, we conducted focus groups with interviewers and cognitive interviews with respondents during and immediately following questionnaire administration in the field to explore their question comprehension and response processes. About 88% of respondents agreed to water quality testing but also desired test results, given the potential implications for their own health. Escherichia coli was present in 36% of drinking water collected at the source, and in 47% of samples consumed in the household. Both questions on water availability necessitated probing by interviewers. About one quarter of households reported emptying of pit latrines and septic tanks, though one-quarter could not provide an answer to the question. Asking questions on menstrual hygiene was acceptable to respondents, but required some clarification and probing. In the context of Belize, this study confirmed the feasibility of collecting information on the availability and quality of drinking water, emptying of sanitation facilities and menstrual hygiene in a multi-purpose household survey, indicating specific areas to improve question formulation and field protocols. Improvements have been incorporated into the latest round of MICS surveys which will be a major source of national data for monitoring of SDG targets for drinking water, sanitation and hygiene and emerging issues for WASH sector programming.

  9. SU-E-T-361: Energy Dependent Radiation/light-Field Misalignment On Truebeam Linear Accelerator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sperling, N; Tanny, S; Parsai, E

    2015-06-15

    Purpose: Verifying the co-incidence of the radiation and light field is recommended by TG-142 for monthly and annual checks. On a digital accelerator, it is simple to verify that beam steering settings are consistent with accepted and commissioned values. This fact should allow for physicists to verify radiation-light-field co-incidence for a single energy and accept that Result for all energies. We present a case where the radiation isocenter deviated for a single energy without any apparent modification to the beam steering parameters. Methods: The radiation isocenter was determined using multiple Methods: Gafchromic film, a BB test, and radiation profiles measuredmore » with a diode. Light-field borders were marked on Gafchromic film and then irradiated for all photon energies. Images of acceptance films were compared with films taken four months later. A phantom with a radio-opaque BB was aligned to isocenter using the light-field and imaged using the EPID for all photon energies. An unshielded diode was aligned using the crosshairs and then beam profiles of multiple field sizes were obtained. Field centers were determined using Omni-Pro v7.4 software, and compared to similar scans taken during commissioning. Beam steering parameter files were checked against backups to determine that the steering parameters were unchanged. Results: There were no differences between the configuration files from acceptance. All three tests demonstrated that a single energy had deviated from accepted values by 0.8 mm in the inline direction. The other two energies remained consistent with previous measurements. The deviated energy was re-steered to be within our clinical tolerance. Conclusions: Our study demonstrates that radiation-light-field coincidence is an energy dependent effect for modern linacs. We recommend that radiation-light-field coincidence be verified for all energies on a monthly basis, particularly for modes used to treat small fields, as these may drift without influencing results from other tests.« less

  10. The PneuCarriage Project: A Multi-Centre Comparative Study to Identify the Best Serotyping Methods for Examining Pneumococcal Carriage in Vaccine Evaluation Studies.

    PubMed

    Satzke, Catherine; Dunne, Eileen M; Porter, Barbara D; Klugman, Keith P; Mulholland, E Kim

    2015-11-01

    The pneumococcus is a diverse pathogen whose primary niche is the nasopharynx. Over 90 different serotypes exist, and nasopharyngeal carriage of multiple serotypes is common. Understanding pneumococcal carriage is essential for evaluating the impact of pneumococcal vaccines. Traditional serotyping methods are cumbersome and insufficient for detecting multiple serotype carriage, and there are few data comparing the new methods that have been developed over the past decade. We established the PneuCarriage project, a large, international multi-centre study dedicated to the identification of the best pneumococcal serotyping methods for carriage studies. Reference sample sets were distributed to 15 research groups for blinded testing. Twenty pneumococcal serotyping methods were used to test 81 laboratory-prepared (spiked) samples. The five top-performing methods were used to test 260 nasopharyngeal (field) samples collected from children in six high-burden countries. Sensitivity and positive predictive value (PPV) were determined for the test methods and the reference method (traditional serotyping of >100 colonies from each sample). For the alternate serotyping methods, the overall sensitivity ranged from 1% to 99% (reference method 98%), and PPV from 8% to 100% (reference method 100%), when testing the spiked samples. Fifteen methods had ≥70% sensitivity to detect the dominant (major) serotype, whilst only eight methods had ≥70% sensitivity to detect minor serotypes. For the field samples, the overall sensitivity ranged from 74.2% to 95.8% (reference method 93.8%), and PPV from 82.2% to 96.4% (reference method 99.6%). The microarray had the highest sensitivity (95.8%) and high PPV (93.7%). The major limitation of this study is that not all of the available alternative serotyping methods were included. Most methods were able to detect the dominant serotype in a sample, but many performed poorly in detecting the minor serotype populations. Microarray with a culture amplification step was the top-performing method. Results from this comprehensive evaluation will inform future vaccine evaluation and impact studies, particularly in low-income settings, where pneumococcal disease burden remains high.

  11. Evaluation of membrane filter field monitors for microbiological air sampling

    NASA Technical Reports Server (NTRS)

    Fields, N. D.; Oxborrow, G. S.; Puleo, J. R.; Herring, C. M.

    1974-01-01

    Due to area constraints encountered in assembly and testing areas of spacecraft, the membrane filter field monitor (MF) and the National Aeronautics and Space Administration-accepted Reyniers slit air sampler were compared for recovery of airborne microbial contamination. The intramural air in a microbiological laboratory area and a clean room environment used for the assembly and testing of the Apollo spacecraft was studied. A significantly higher number of microorganisms was recovered by the Reyniers sampler. A high degree of consistency between the two sampling methods was shown by a regression analysis, with a correlation coefficient of 0.93. The MF samplers detected 79% of the concentration measured by the Reyniers slit samplers. The types of microorganisms identified from both sampling methods were similar.

  12. A 'range test' for determining scatterers with unknown physical properties

    NASA Astrophysics Data System (ADS)

    Potthast, Roland; Sylvester, John; Kusiak, Steven

    2003-06-01

    We describe a new scheme for determining the convex scattering support of an unknown scatterer when the physical properties of the scatterers are not known. The convex scattering support is a subset of the scatterer and provides information about its location and estimates for its shape. For convex polygonal scatterers the scattering support coincides with the scatterer and we obtain full shape reconstructions. The method will be formulated for the reconstruction of the scatterers from the far field pattern for one or a few incident waves. The method is non-iterative in nature and belongs to the type of recently derived generalized sampling schemes such as the 'no response test' of Luke-Potthast. The range test operates by testing whether it is possible to analytically continue a far field to the exterior of any test domain Omegatest. By intersecting the convex hulls of various test domains we can produce a minimal convex set, the convex scattering support of which must be contained in the convex hull of the support of any scatterer which produces that far field. The convex scattering support is calculated by testing the range of special integral operators for a sampling set of test domains. The numerical results can be used as an approximation for the support of the unknown scatterer. We prove convergence and regularity of the scheme and show numerical examples for sound-soft, sound-hard and medium scatterers. We can apply the range test to non-convex scatterers as well. We can conclude that an Omegatest which passes the range test has a non-empty intersection with the infinity-support (the complement of the unbounded component of the complement of the support) of the true scatterer, but cannot find a minimal set which must be contained therein.

  13. Conservatism implications of shock test tailoring for multiple design environments

    NASA Technical Reports Server (NTRS)

    Baca, Thomas J.; Bell, R. Glenn; Robbins, Susan A.

    1987-01-01

    A method for analyzing shock conservation in test specifications that have been tailored to qualify a structure for multiple design environments is discussed. Shock test conservation is qualified for shock response spectra, shock intensity spectra and ranked peak acceleration data in terms of an Index of Conservation (IOC) and an Overtest Factor (OTF). The multi-environment conservation analysis addresses the issue of both absolute and average conservation. The method is demonstrated in a case where four laboratory tests have been specified to qualify a component which must survive seven different field environments. Final judgment of the tailored test specification is shown to require an understanding of the predominant failure modes of the test item.

  14. Numerical inverse method predicting acoustic spinning modes radiated by a ducted fan from free-field test data.

    PubMed

    Lewy, Serge

    2008-07-01

    Spinning modes generated by a ducted turbofan at a given frequency determine the acoustic free-field directivity. An inverse method starting from measured directivity patterns is interesting in providing information on the noise sources without requiring tedious spinning-mode experimental analyses. According to a previous article, equations are based on analytical modal splitting inside a cylindrical duct and on a Rayleigh or a Kirchhoff integral on the duct exit cross section to get far-field directivity. Equations are equal in number to free-field measurement locations and the unknowns are the propagating mode amplitudes (there are generally more unknowns than equations). A MATLAB procedure has been implemented by using either the pseudoinverse function or the backslash operator. A constraint comes from the fact that squared modal amplitudes must be positive which involves an iterative least squares fitting. Numerical simulations are discussed along with several examples based on tests performed by Rolls-Royce in the framework of a European project. It is assessed that computation is very fast and it well fits the measured directivities, but the solution depends on the method and is not unique. This means that the initial set of modes should be chosen according to any known physical property of the acoustic sources.

  15. The Impact of Sound-Field Systems on Learning and Attention in Elementary School Classrooms

    ERIC Educational Resources Information Center

    Dockrell, Julie E.; Shield, Bridget

    2012-01-01

    Purpose: The authors evaluated the installation and use of sound-field systems to investigate the impact of these systems on teaching and learning in elementary school classrooms. Methods: The evaluation included acoustic surveys of classrooms, questionnaire surveys of students and teachers, and experimental testing of students with and without…

  16. A Field-Based Aquatic Life Benchmark for Conductivity in Central Appalachian Streams (2010) (External Review Draft)

    EPA Science Inventory

    This report adapts the standard U.S. EPA methodology for deriving ambient water quality criteria. Rather than use toxicity test results, the adaptation uses field data to determine the loss of 5% of genera from streams. The method is applied to derive effect benchmarks for disso...

  17. Quality control tests of lab-reared Cydia pomonella and Cactoblastis cactorum field performance: Comparison of laboratory and field bioassays.

    USDA-ARS?s Scientific Manuscript database

    Research, operational, and commercial programs which rely on mass-reared insects of high quality and performance, need accurate methods for monitoring quality degradation during each step of production, handling and release. With continued interest in the use of the sterile insect technique (SIT) a...

  18. Field assessment of wood stake decomposition in forest soil

    Treesearch

    Xiping Wang; Deborah Page-Dumroese; Martin F. Jurgensen; Robert J. Ross

    2007-01-01

    A pulse-echo acoustic method was investigated for evaluating wood stake decomposition in the field. A total of 58 wood stakes (29 loblolly pine, Pinus taeda, and 29 aspen, Populus tremuloides) that were vertically installed (full length) in forest soils were non-destructively tested by means of a laboratory-type acoustic...

  19. Development of a field testing protocol for identifying Deepwater Horizon oil spill residues trapped near Gulf of Mexico beaches.

    PubMed

    Han, Yuling; Clement, T Prabhakar

    2018-01-01

    The Deepwater Horizon (DWH) accident, one of the largest oil spills in U.S. history, contaminated several beaches located along the Gulf of Mexico (GOM) shoreline. The residues from the spill still continue to be deposited on some of these beaches. Methods to track and monitor the fate of these residues require approaches that can differentiate the DWH residues from other types of petroleum residues. This is because, historically, the crude oil released from sources such as natural seeps and anthropogenic discharges have also deposited other types of petroleum residues on GOM beaches. Therefore, identifying the origin of these residues is critical for developing effective management strategies for monitoring the long-term environmental impacts of the DWH oil spill. Advanced fingerprinting methods that are currently used for identifying the source of oil spill residues require detailed laboratory studies, which can be cost-prohibitive. Also, most agencies typically use untrained workers or volunteers to conduct shoreline monitoring surveys and these worker will not have access to advanced laboratory facilities. Furthermore, it is impractical to routinely fingerprint large volumes of samples that are collected after a major oil spill event, such as the DWH spill. In this study, we propose a simple field testing protocol that can identify DWH oil spill residues based on their unique physical characteristics. The robustness of the method is demonstrated by testing a variety of oil spill samples, and the results are verified by characterizing the samples using advanced chemical fingerprinting methods. The verification data show that the method yields results that are consistent with the results derived from advanced fingerprinting methods. The proposed protocol is a reliable, cost-effective, practical field approach for differentiating DWH residues from other types of petroleum residues.

  20. Development of a field testing protocol for identifying Deepwater Horizon oil spill residues trapped near Gulf of Mexico beaches

    PubMed Central

    Han, Yuling

    2018-01-01

    The Deepwater Horizon (DWH) accident, one of the largest oil spills in U.S. history, contaminated several beaches located along the Gulf of Mexico (GOM) shoreline. The residues from the spill still continue to be deposited on some of these beaches. Methods to track and monitor the fate of these residues require approaches that can differentiate the DWH residues from other types of petroleum residues. This is because, historically, the crude oil released from sources such as natural seeps and anthropogenic discharges have also deposited other types of petroleum residues on GOM beaches. Therefore, identifying the origin of these residues is critical for developing effective management strategies for monitoring the long-term environmental impacts of the DWH oil spill. Advanced fingerprinting methods that are currently used for identifying the source of oil spill residues require detailed laboratory studies, which can be cost-prohibitive. Also, most agencies typically use untrained workers or volunteers to conduct shoreline monitoring surveys and these worker will not have access to advanced laboratory facilities. Furthermore, it is impractical to routinely fingerprint large volumes of samples that are collected after a major oil spill event, such as the DWH spill. In this study, we propose a simple field testing protocol that can identify DWH oil spill residues based on their unique physical characteristics. The robustness of the method is demonstrated by testing a variety of oil spill samples, and the results are verified by characterizing the samples using advanced chemical fingerprinting methods. The verification data show that the method yields results that are consistent with the results derived from advanced fingerprinting methods. The proposed protocol is a reliable, cost-effective, practical field approach for differentiating DWH residues from other types of petroleum residues. PMID:29329313

  1. Effect of Facet Displacement on Radiation Field and Its Application for Panel Adjustment of Large Reflector Antenna

    NASA Astrophysics Data System (ADS)

    Wang, Wei; Lian, Peiyuan; Zhang, Shuxin; Xiang, Binbin; Xu, Qian

    2017-05-01

    Large reflector antennas are widely used in radars, satellite communication, radio astronomy, and so on. The rapid developments in these fields have created demands for development of better performance and higher surface accuracy. However, low accuracy and low efficiency are the common disadvantages for traditional panel alignment and adjustment. In order to improve the surface accuracy of large reflector antenna, a new method is presented to determinate panel adjustment values from far field pattern. Based on the method of Physical Optics (PO), the effect of panel facet displacement on radiation field value is derived. Then the linear system is constructed between panel adjustment vector and far field pattern. Using the method of Singular Value Decomposition (SVD), the adjustment value for all panel adjustors are obtained by solving the linear equations. An experiment is conducted on a 3.7 m reflector antenna with 12 segmented panels. The results of simulation and test are similar, which shows that the presented method is feasible. Moreover, the discussion about validation shows that the method can be used for many cases of reflector shape. The proposed research provides the instruction to adjust surface panels efficiently and accurately.

  2. A field test of electromagnetic geophysical techniques for locating simulated in situ mining leach solution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tweeton, D.R.; Hanson, J.C.; Friedel, M.J.

    1994-01-01

    The US Bureau of Mines, The University of Arizona, Sandia National Laboratories, and Zonge Engineering and Research Organization, Inc., conducted cooperative field tests of six electromagnetic (EM) geophysical methods to compare their effectiveness in locating a brine solution simulating in situ leach solution or a high-conductivity plume of contamination. The brine was approximately 160 m below the surface. The testsite was the University's San Xavier experimental mine near Tucson, AZ. Geophysical surveys using surface and surface-borehole, time-domain electromagnetic (TEM) induction; surface controlled-source audiofrequency magnetotellurics (CSAMT); surface-borehole, frequency-domain electromagnetic (FEM) induction; crosshole FEM; and surface magnetic field ellipticity were conducted beforemore » and during brine injection. The surface TEM data showed a broad decrease in resistivity. CSAMT measurements with the conventional orientation did not detect the brine, but measurements with another orientation indicated some decrease in resistivity. The surface-borehole and crosshole methods located a known fracture and other fracture zones inferred from borehole induction logs. Surface magnetic field ellipticity data showed a broad decrease in resistivity at depth following brine injection.« less

  3. Mechanical testing of hydrogels in cartilage tissue engineering: beyond the compressive modulus.

    PubMed

    Xiao, Yinghua; Friis, Elizabeth A; Gehrke, Stevin H; Detamore, Michael S

    2013-10-01

    Injuries to articular cartilage result in significant pain to patients and high medical costs. Unfortunately, cartilage repair strategies have been notoriously unreliable and/or complex. Biomaterial-based tissue-engineering strategies offer great promise, including the use of hydrogels to regenerate articular cartilage. Mechanical integrity is arguably the most important functional outcome of engineered cartilage, although mechanical testing of hydrogel-based constructs to date has focused primarily on deformation rather than failure properties. In addition to deformation testing, as the field of cartilage tissue engineering matures, this community will benefit from the addition of mechanical failure testing to outcome analyses, given the crucial clinical importance of the success of engineered constructs. However, there is a tremendous disparity in the methods used to evaluate mechanical failure of hydrogels and articular cartilage. In an effort to bridge the gap in mechanical testing methods of articular cartilage and hydrogels in cartilage regeneration, this review classifies the different toughness measurements for each. The urgency for identifying the common ground between these two disparate fields is high, as mechanical failure is ready to stand alongside stiffness as a functional design requirement. In comparing toughness measurement methods between hydrogels and cartilage, we recommend that the best option for evaluating mechanical failure of hydrogel-based constructs for cartilage tissue engineering may be tensile testing based on the single edge notch test, in part because specimen preparation is more straightforward and a related American Society for Testing and Materials (ASTM) standard can be adopted in a fracture mechanics context.

  4. Development of criteria for the use of asphalt-rubber as a Stress-Absorbing Membrane Interlayer (SAMI)

    NASA Astrophysics Data System (ADS)

    Newcomb, D. E.; McKeen, R. G.

    1983-12-01

    This report documents over 2 years of research efforts to characterize asphalt-rubber mixtures to be used in Stress-Absorbing Membrane Interlayers (SAMI). The purpose of these SAMIs is to retard or prevent reflection cracking in asphalt-concrete overlays. Several laboratory experiments and one field trial were conducted to define significant test methods and parameters for incorporation into construction design and specification documents. Test methods used in this study included a modified softening point test, force-ductility, and Schweyer viscosity. Variables investigated included (1) Laboratory-mixing temperature; (2) Rubber type; (3) Laboratory storage time; (4) Laboratory storage condition; (5) Laboratory batch replication; (6) Laboratory mixing time; (7) Field mixing time; (8) Laboratory test temperature; (9) Force-Ductility elongation rates; and (10) Asphalt grade. It was found that mixing temperature, mixing time, rubber type, and asphalt grade all have significant effects upon the behavior of asphalt-rubber mixtures. Significant variability was also noticed in different laboratory batch replications. Varying laboratory test temperature and force-ductility elongation rate revealed further differences in asphalt-rubber mixtures.

  5. Power Hardware-in-the-Loop Evaluation of PV Inverter Grid Support on Hawaiian Electric Feeders

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelson, Austin A; Prabakar, Kumaraguru; Nagarajan, Adarsh

    As more grid-connected photovoltaic (PV) inverters become compliant with evolving interconnections requirements, there is increased interest from utilities in understanding how to best deploy advanced grid-support functions (GSF) in the field. One efficient and cost-effective method to examine such deployment options is to leverage power hardware-in-the-loop (PHIL) testing methods, which combine the fidelity of hardware tests with the flexibility of computer simulation. This paper summarizes a study wherein two Hawaiian Electric feeder models were converted to real-time models using an OPAL-RT real-time digital testing platform, and integrated with models of GSF capable PV inverters based on characterization test data. Themore » integrated model was subsequently used in PHIL testing to evaluate the effects of different fixed power factor and volt-watt control settings on voltage regulation of the selected feeders using physical inverters. Selected results are presented in this paper, and complete results of this study were provided as inputs for field deployment and technical interconnection requirements for grid-connected PV inverters on the Hawaiian Islands.« less

  6. Infrared non-destructive evaluation method and apparatus

    DOEpatents

    Baleine, Erwan; Erwan, James F; Lee, Ching-Pang; Stinelli, Stephanie

    2014-10-21

    A method of nondestructive evaluation and related system. The method includes arranging a test piece (14) having an internal passage (18) and an external surface (15) and a thermal calibrator (12) within a field of view (42) of an infrared sensor (44); generating a flow (16) of fluid characterized by a fluid temperature; exposing the test piece internal passage (18) and the thermal calibrator (12) to fluid from the flow (16); capturing infrared emission information of the test piece external surface (15) and of the thermal calibrator (12) simultaneously using the infrared sensor (44), wherein the test piece infrared emission information includes emission intensity information, and wherein the thermal calibrator infrared emission information includes a reference emission intensity associated with the fluid temperature; and normalizing the test piece emission intensity information against the reference emission intensity.

  7. Nondestructive acoustic electric field probe apparatus and method

    DOEpatents

    Migliori, Albert

    1982-01-01

    The disclosure relates to a nondestructive acoustic electric field probe and its method of use. A source of acoustic pulses of arbitrary but selected shape is placed in an oil bath along with material to be tested across which a voltage is disposed and means for receiving acoustic pulses after they have passed through the material. The received pulses are compared with voltage changes across the material occurring while acoustic pulses pass through it and analysis is made thereof to determine preselected characteristics of the material.

  8. Testing strong-segregation theory against self-consistent-field theory for block copolymer melts

    NASA Astrophysics Data System (ADS)

    Matsen, M. W.

    2001-06-01

    We introduce a highly efficient self-consistent-field theory (SCFT) method for examining the cylindrical and spherical block copolymer morphologies using a standard unit cell approximation (UCA). The method is used to calculate the classical diblock copolymer phase boundaries deep into the strong-segregation regime, where they can be compared with recent improvements to strong-segregation theory (SST). The comparison suggests a significant discrepancy between the two theories indicating that our understanding of strongly stretched polymer brushes is still incomplete.

  9. Design, analysis and test verification of advanced encapsulation systems

    NASA Technical Reports Server (NTRS)

    Garcia, A., III

    1984-01-01

    Investigations into transparent conductive polymers were begun. Polypyrrole was electrochemically deposited, but the film characteristics were poor. A proprietary polymer material supplied by Polaroid was evaluated and showed promise as a readily processable material. A method was developed for calculating the magnitude and location of the maximum electric field for the family of solar-cell-like shapes. A method for calculating the lines of force for three dimensional electric fields was developed and applied to a geometry of interest to the photovoltaic program.

  10. Electromagnetic Imaging Methods for Nondestructive Evaluation Applications

    PubMed Central

    Deng, Yiming; Liu, Xin

    2011-01-01

    Electromagnetic nondestructive tests are important and widely used within the field of nondestructive evaluation (NDE). The recent advances in sensing technology, hardware and software development dedicated to imaging and image processing, and material sciences have greatly expanded the application fields, sophisticated the systems design and made the potential of electromagnetic NDE imaging seemingly unlimited. This review provides a comprehensive summary of research works on electromagnetic imaging methods for NDE applications, followed by the summary and discussions on future directions. PMID:22247693

  11. Periodic Pulay method for robust and efficient convergence acceleration of self-consistent field iterations

    DOE PAGES

    Banerjee, Amartya S.; Suryanarayana, Phanish; Pask, John E.

    2016-01-21

    Pulay's Direct Inversion in the Iterative Subspace (DIIS) method is one of the most widely used mixing schemes for accelerating the self-consistent solution of electronic structure problems. In this work, we propose a simple generalization of DIIS in which Pulay extrapolation is performed at periodic intervals rather than on every self-consistent field iteration, and linear mixing is performed on all other iterations. Lastly, we demonstrate through numerical tests on a wide variety of materials systems in the framework of density functional theory that the proposed generalization of Pulay's method significantly improves its robustness and efficiency.

  12. Neural Network Prediction of Failure of Damaged Composite Pressure Vessels from Strain Field Data Acquired by a Computer Vision Method

    NASA Technical Reports Server (NTRS)

    Russell, Samuel S.; Lansing, Matthew D.

    1997-01-01

    This effort used a new and novel method of acquiring strains called Sub-pixel Digital Video Image Correlation (SDVIC) on impact damaged Kevlar/epoxy filament wound pressure vessels during a proof test. To predict the burst pressure, the hoop strain field distribution around the impact location from three vessels was used to train a neural network. The network was then tested on additional pressure vessels. Several variations on the network were tried. The best results were obtained using a single hidden layer. SDVIC is a fill-field non-contact computer vision technique which provides in-plane deformation and strain data over a load differential. This method was used to determine hoop and axial displacements, hoop and axial linear strains, the in-plane shear strains and rotations in the regions surrounding impact sites in filament wound pressure vessels (FWPV) during proof loading by internal pressurization. The relationship between these deformation measurement values and the remaining life of the pressure vessels, however, requires a complex theoretical model or numerical simulation. Both of these techniques are time consuming and complicated. Previous results using neural network methods had been successful in predicting the burst pressure for graphite/epoxy pressure vessels based upon acoustic emission (AE) measurements in similar tests. The neural network associates the character of the AE amplitude distribution, which depends upon the extent of impact damage, with the burst pressure. Similarly, higher amounts of impact damage are theorized to cause a higher amount of strain concentration in the damage effected zone at a given pressure and result in lower burst pressures. This relationship suggests that a neural network might be able to find an empirical relationship between the SDVIC strain field data and the burst pressure, analogous to the AE method, with greater speed and simplicity than theoretical or finite element modeling. The process of testing SDVIC neural network analysis and some encouraging preliminary results are presented in this paper. Details are given concerning the processing of SDVIC output data such that it may be used as back propagation neural network (BPNN) input data. The software written to perform this processing and the BPNN algorithm are also discussed. It will be shown that, with limited training, test results indicate an average error in burst pressure prediction of approximately six percent,

  13. Sparse Reconstruction of Electric Fields from Radial Magnetic Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yeates, Anthony R.

    2017-02-10

    Accurate estimates of the horizontal electric field on the Sun’s visible surface are important not only for estimating the Poynting flux of magnetic energy into the corona but also for driving time-dependent magnetohydrodynamic models of the corona. In this paper, a method is developed for estimating the horizontal electric field from a sequence of radial-component magnetic field maps. This problem of inverting Faraday’s law has no unique solution. Unfortunately, the simplest solution (a divergence-free electric field) is not realistically localized in regions of nonzero magnetic field, as would be expected from Ohm’s law. Our new method generates instead a localizedmore » solution, using a basis pursuit algorithm to find a sparse solution for the electric field. The method is shown to perform well on test cases where the input magnetic maps are flux balanced in both Cartesian and spherical geometries. However, we show that if the input maps have a significant imbalance of flux—usually arising from data assimilation—then it is not possible to find a localized, realistic, electric field solution. This is the main obstacle to driving coronal models from time sequences of solar surface magnetic maps.« less

  14. The establishment and application of direct coupled electrostatic-structural field model in electrostatically controlled deployable membrane antenna

    NASA Astrophysics Data System (ADS)

    Gu, Yongzhen; Duan, Baoyan; Du, Jingli

    2018-05-01

    The electrostatically controlled deployable membrane antenna (ECDMA) is a promising space structure due to its low weight, large aperture and high precision characteristics. However, it is an extreme challenge to describe the coupled field between electrostatic and membrane structure accurately. A direct coupled method is applied to solve the coupled problem in this paper. Firstly, the membrane structure and electrostatic field are uniformly described by energy, considering the coupled problem is an energy conservation phenomenon. Then the direct coupled electrostatic-structural field governing equilibrium equations are obtained by energy variation approach. Numerical results show that the direct coupled method improves the computing efficiency by 36% compared with the traditional indirect coupled method with the same level accuracy. Finally, the prototype has been manufactured and tested and the ECDMA finite element simulations show good agreement with the experiment results as the maximum surface error difference is 6%.

  15. The Leeb Hardness Test for Rock: An Updated Methodology and UCS Correlation

    NASA Astrophysics Data System (ADS)

    Corkum, A. G.; Asiri, Y.; El Naggar, H.; Kinakin, D.

    2018-03-01

    The Leeb hardness test (LHT with test value of L D ) is a rebound hardness test, originally developed for metals, that has been correlated with the Unconfined Compressive Strength (test value of σ c ) of rock by several authors. The tests can be carried out rapidly, conveniently and nondestructively on core and block samples or on rock outcrops. This makes the relatively small LHT device convenient for field tests. The present study compiles test data from literature sources and presents new laboratory testing carried out by the authors to develop a substantially expanded database with wide-ranging rock types. In addition, the number of impacts that should be averaged to comprise a "test result" was revisited along with the issue of test specimen size. Correlation for L D and σ c for various rock types is provided along with recommended testing methodology. The accuracy of correlated σ c estimates was assessed and reasonable correlations were observed between L D and σ c . The study findings show that LHT can be useful particularly for field estimation of σ c and offers a significant improvement over the conventional field estimation methods outlined by the ISRM (e.g., hammer blows). This test is rapid and simple, with relatively low equipment costs, and provides a reasonably accurate estimate of σ c .

  16. Overview of U.S. EPA Office of Research and Development’s planned research on analysis and monitoring in fresh and coastal/estuarine environments

    EPA Science Inventory

    This research plan has several objectives: 1) develop new or refine existing chemical, instrument and biological methods for the detection of cyanobacteria and their toxins; test such methods in field studies in both HAB and non HAB environments; 2) determine the method(s) that c...

  17. A Comparison of Methods to Analyze Aquatic Heterotrophic Flagellates of Different Taxonomic Groups.

    PubMed

    Jeuck, Alexandra; Nitsche, Frank; Wylezich, Claudia; Wirth, Olaf; Bergfeld, Tanja; Brutscher, Fabienne; Hennemann, Melanie; Monir, Shahla; Scherwaß, Anja; Troll, Nicole; Arndt, Hartmut

    2017-08-01

    Heterotrophic flagellates contribute significantly to the matter flux in aquatic and terrestrial ecosystems. Still today their quantification and taxonomic classification bear several problems in field studies, though these methodological problems seem to be increasingly ignored in current ecological studies. Here we describe and test different methods, the live-counting technique, different fixation techniques, cultivation methods like the liquid aliquot method (LAM), and a molecular single cell survey called aliquot PCR (aPCR). All these methods have been tested either using aquatic field samples or cultures of freshwater and marine taxa. Each of the described methods has its advantages and disadvantages, which have to be considered in every single case. With the live-counting technique a detection of living cells up to morphospecies level is possible. Fixation of cells and staining methods are advantageous due to the possible long-term storage and observation of samples. Cultivation methods (LAM) offer the possibility of subsequent molecular analyses, and aPCR tools might complete the deficiency of LAM in terms of the missing detection of non-cultivable flagellates. In summary, we propose a combination of several investigation techniques reducing the gap between the different methodological problems. Copyright © 2017 Elsevier GmbH. All rights reserved.

  18. Recommended use of reclaimed asphalt pavement in the Superpave mix design method: technician's manual.

    DOT National Transportation Integrated Search

    2001-01-01

    This manual is a reference guide for mix design and field testing technicians who deal with reclaimed asphalt pavement (RAP) in Superpave mixtures. It will provide detailed descriptions and examples of each step involved in designing and testing a Su...

  19. Technical Note: Harmonic analysis applied to MR image distortion fields specific to arbitrarily shaped volumes.

    PubMed

    Stanescu, T; Jaffray, D

    2018-05-25

    Magnetic resonance imaging is expected to play a more important role in radiation therapy given the recent developments in MR-guided technologies. MR images need to consistently show high spatial accuracy to facilitate RT specific tasks such as treatment planning and in-room guidance. The present study investigates a new harmonic analysis method for the characterization of complex 3D fields derived from MR images affected by system-related distortions. An interior Dirichlet problem based on solving the Laplace equation with boundary conditions (BCs) was formulated for the case of a 3D distortion field. The second-order boundary value problem (BVP) was solved using a finite elements method (FEM) for several quadratic geometries - i.e., sphere, cylinder, cuboid, D-shaped, and ellipsoid. To stress-test the method and generalize it, the BVP was also solved for more complex surfaces such as a Reuleaux 9-gon and the MR imaging volume of a scanner featuring a high degree of surface irregularities. The BCs were formatted from reference experimental data collected with a linearity phantom featuring a volumetric grid structure. The method was validated by comparing the harmonic analysis results with the corresponding experimental reference fields. The harmonic fields were found to be in good agreement with the baseline experimental data for all geometries investigated. In the case of quadratic domains, the percentage of sampling points with residual values larger than 1 mm were 0.5% and 0.2% for the axial components and vector magnitude, respectively. For the general case of a domain defined by the available MR imaging field of view, the reference data showed a peak distortion of about 12 mm and 79% of the sampling points carried a distortion magnitude larger than 1 mm (tolerance intrinsic to the experimental data). The upper limits of the residual values after comparison with the harmonic fields showed max and mean of 1.4 mm and 0.25 mm, respectively, with only 1.5% of sampling points exceeding 1 mm. A novel harmonic analysis approach relying on finite element methods was introduced and validated for multiple volumes with surface shape functions ranging from simple to highly complex. Since a boundary value problem is solved the method requires input data from only the surface of the desired domain of interest. It is believed that the harmonic method will facilitate (a) the design of new phantoms dedicated for the quantification of MR image distortions in large volumes and (b) an integrative approach of combining multiple imaging tests specific to radiotherapy into a single test object for routine imaging quality control. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  20. Artificial testing targets with controllable blur for adaptive optics microscopes

    NASA Astrophysics Data System (ADS)

    Hattori, Masayuki; Tamada, Yosuke; Murata, Takashi; Oya, Shin; Hasebe, Mitsuyasu; Hayano, Yutaka; Kamei, Yasuhiro

    2017-08-01

    This letter proposes a method of configuring a testing target to evaluate the performance of adaptive optics microscopes. In this method, a testing slide with fluorescent beads is used to simultaneously determine the point spread function and the field of view. The point spread function is reproduced to simulate actual biological samples by etching a microstructure on the cover glass. The fabrication process is simplified to facilitate an onsite preparation. The artificial tissue consists of solid materials and silicone oil and is stable for use in repetitive experiments.

  1. Retrieving Storm Electric Fields from Aircrfaft Field Mill Data: Part II: Applications

    NASA Technical Reports Server (NTRS)

    Koshak, William; Mach, D. M.; Christian H. J.; Stewart, M. F.; Bateman M. G.

    2006-01-01

    The Lagrange multiplier theory developed in Part I of this study is applied to complete a relative calibration of a Citation aircraft that is instrumented with six field mill sensors. When side constraints related to average fields are used, the Lagrange multiplier method performs well in computer simulations. For mill measurement errors of 1 V m(sup -1) and a 5 V m(sup -1) error in the mean fair-weather field function, the 3D storm electric field is retrieved to within an error of about 12%. A side constraint that involves estimating the detailed structure of the fair-weather field was also tested using computer simulations. For mill measurement errors of 1 V m(sup -l), the method retrieves the 3D storm field to within an error of about 8% if the fair-weather field estimate is typically within 1 V m(sup -1) of the true fair-weather field. Using this type of side constraint and data from fair-weather field maneuvers taken on 29 June 2001, the Citation aircraft was calibrated. Absolute calibration was completed using the pitch down method developed in Part I, and conventional analyses. The resulting calibration matrices were then used to retrieve storm electric fields during a Citation flight on 2 June 2001. The storm field results are encouraging and agree favorably in many respects with results derived from earlier (iterative) techniques of calibration.

  2. On Blockage Corrections for Two-dimensional Wind Tunnel Tests Using the Wall-pressure Signature Method

    NASA Technical Reports Server (NTRS)

    Allmaras, S. R.

    1986-01-01

    The Wall-Pressure Signature Method for correcting low-speed wind tunnel data to free-air conditions has been revised and improved for two-dimensional tests of bluff bodies. The method uses experimentally measured tunnel wall pressures to approximately reconstruct the flow field about the body with potential sources and sinks. With the use of these sources and sinks, the measured drag and tunnel dynamic pressure are corrected for blockage effects. Good agreement is obtained with simpler methods for cases in which the blockage corrections were about 10% of the nominal drag values.

  3. A 3D front tracking method on a CPU/GPU system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bo, Wurigen; Grove, John

    2011-01-21

    We describe the method to port a sequential 3D interface tracking code to a GPU with CUDA. The interface is represented as a triangular mesh. Interface geometry properties and point propagation are performed on a GPU. Interface mesh adaptation is performed on a CPU. The convergence of the method is assessed from the test problems with given velocity fields. Performance results show overall speedups from 11 to 14 for the test problems under mesh refinement. We also briefly describe our ongoing work to couple the interface tracking method with a hydro solver.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rotti, Aditya; Huffenberger, Kevin, E-mail: adityarotti@gmail.com, E-mail: khuffenberger@fsu.edu

    Isotropy-violation statistics can highlight polarized galactic foregrounds that contaminate primordial B -modes in the Cosmic Microwave Background (CMB). We propose a particular isotropy-violation test and apply it to polarized Planck 353 GHz data, constructing a map that indicates B -mode foreground dust power over the sky. We build our main isotropy test in harmonic space via the bipolar spherical harmonic basis, and our method helps us to identify the least-contaminated directions. By this measure, there are regions of low foreground in and around the BICEP field, near the South Galactic Pole, and in the Northern Galactic Hemisphere. There is alsomore » a possible foreground feature in the BICEP field. We compare our results to those based on the local power spectrum, which is computed on discs using a version of the method of Planck Int. XXX (2016). The discs method is closely related to our isotropy-violation diagnostic. We pay special care to the treatment of noise, including chance correlations with the foregrounds. Currently we use our isotropy tool to assess the cleanest portions of the sky, but in the future such methods will allow isotropy-based null tests for foreground contamination in maps purported to measure primordial B -modes, particularly in cases of limited frequency coverage.« less

  5. A resilient domain decomposition polynomial chaos solver for uncertain elliptic PDEs

    NASA Astrophysics Data System (ADS)

    Mycek, Paul; Contreras, Andres; Le Maître, Olivier; Sargsyan, Khachik; Rizzi, Francesco; Morris, Karla; Safta, Cosmin; Debusschere, Bert; Knio, Omar

    2017-07-01

    A resilient method is developed for the solution of uncertain elliptic PDEs on extreme scale platforms. The method is based on a hybrid domain decomposition, polynomial chaos (PC) framework that is designed to address soft faults. Specifically, parallel and independent solves of multiple deterministic local problems are used to define PC representations of local Dirichlet boundary-to-boundary maps that are used to reconstruct the global solution. A LAD-lasso type regression is developed for this purpose. The performance of the resulting algorithm is tested on an elliptic equation with an uncertain diffusivity field. Different test cases are considered in order to analyze the impacts of correlation structure of the uncertain diffusivity field, the stochastic resolution, as well as the probability of soft faults. In particular, the computations demonstrate that, provided sufficiently many samples are generated, the method effectively overcomes the occurrence of soft faults.

  6. A spot pattern test chart technique for measurement of geometric aberrations caused by an intervening medium—a novel method

    NASA Astrophysics Data System (ADS)

    Ganesan, A. R.; Arulmozhivarman, P.; Jesson, M.

    2005-12-01

    Accurate surface metrology and transmission characteristics measurements have become vital to certify the manufacturing excellence in the field of glass visors, windshields, menu boards and transportation industries. We report a simple, cost-effective and novel technique for the measurement of geometric aberrations in transparent materials such as glass sheets, Perspex, etc. The technique makes use of an array of spot pattern, we call the spot pattern test chart technique, in the diffraction limited imaging position having large field of view. Performance features include variable angular dynamic range and angular sensitivity. Transparent sheets as the intervening medium introduced in the line of sight, causing aberrations, are estimated in real time using the Zernike reconstruction method. Quantitative comparative analysis between a Shack-Hartmann wavefront sensor and the proposed new method is presented and the results are discussed.

  7. Consistent approach to describing aircraft HIRF protection

    NASA Technical Reports Server (NTRS)

    Rimbey, P. R.; Walen, D. B.

    1995-01-01

    The high intensity radiated fields (HIRF) certification process as currently implemented is comprised of an inconsistent combination of factors that tend to emphasize worst case scenarios in assessing commercial airplane certification requirements. By examining these factors which include the process definition, the external HIRF environment, the aircraft coupling and corresponding internal fields, and methods of measuring equipment susceptibilities, activities leading to an approach to appraising airplane vulnerability to HIRF are proposed. This approach utilizes technically based criteria to evaluate the nature of the threat, including the probability of encountering the external HIRF environment. No single test or analytic method comprehensively addresses the full HIRF threat frequency spectrum. Additional tools such as statistical methods must be adopted to arrive at more realistic requirements to reflect commercial aircraft vulnerability to the HIRF threat. Test and analytic data are provided to support the conclusions of this report. This work was performed under NASA contract NAS1-19360, Task 52.

  8. Evaluation of a standard test method for screening fuels in soils

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sorini, S.S.; Schabron, J.F.

    1996-12-31

    A new screening method for fuel contamination in soils was recently developed as American Society for Testing and Materials (ASTM) Method D-5831-95, Standard Test Method for Screening Fuels in Soils. This method uses low-toxicity chemicals and can be sued to screen organic- rich soils, as well as being fast, easy, and inexpensive to perform. Fuels containing aromatic compounds, such as diesel fuel and gasoline, as well as other aromatic-containing hydrocarbon materials, such as motor oil, crude oil, and cola oil, can be determined. The screening method for fuels in soils was evaluated by conducting a Collaborative study on the method.more » In the Collaborative study, a sand and an organic soil spiked with various concentrations of diesel fuel were tested. Data from the Collaborative study were used to determine the reproducibility (between participants) and repeatability (within participants) precision of the method for screening the test materials. The Collaborative study data also provide information on the performance of portable field equipment (patent pending) versus laboratory equipment for performing the screening method and a comparison of diesel concentration values determined using the screening method versus a laboratory method.« less

  9. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; arsenic speciation in natural-water samples using laboratory and field methods

    USGS Publications Warehouse

    Garbarino, John R.; Bednar, Anthony J.; Burkhardt, Mark R.

    2002-01-01

    Analytical methods for the determination of arsenite [As(III)], arsenate [As(V)], dimethylarsinate (DMA), monomethylarsonate (MMA), and roxarsone in filtered natural-water samples are described. Various analytical methods can be used for the determination, depending on the arsenic species being determined. Arsenic concentration is determined by using inductively coupled plasma-mass spectrometry (ICP-MS) as an arsenic-specific detector for all methods. Laboratory-speciation methods are described that use an ion chromatographic column to separate the arsenic species; the column length, column packing, and mobile phase are dependent on the species of interest. Regardless of the separation technique, the arsenic species are introduced into plasma by eithe rpneumatic nebulization or arsine generation. Analysis times range from 2 to 8 minutes and method detection limits range from 0.1 to 0.6 microgram-arsenic per liter (ug-As/L), 10 to 60 picograms absolute (for a 100-microliter injection), depending on the arsenic species determined and the analytical method used. A field-generation specciation method also is described that uses a strong anion exchange cartridge to separate As(III) from As(V) in the field. As(III) in the eluate and the As(V) in the cartridge extract are determined by direct nebulization ICP-MS. Methylated arsenic species that also are retained on the cartridge will positively bias As(V) results without further laboratory separations. The method detection limit for field speciation is 0.3 ug-As/L. The distribution of arsenic species must be preserved in the field to eliminate changes caused by photochemical oxidation or metal oxyhydroxide precipitation. Preservation techniques, such as refrigeration, the addition of acides, or the additoin of ethylene-diaminetetraacetic acid (EDTA) and the effects of ambient light were tested. Of the preservatives evaluated, EDTA was found to work best with the laboratory- and field-speciation methods for all sample matrices tested. Storing the samples in opaque polytethylene bottles eliminated the effects of photochemical oxidation. The percentage change in As(III):As(V) ratios for an EDTA-preserved acid mine drainage (AMD) sample and ground-water sample during a 3-month period was -5 percent and +3 percent, respectively. The bias and variability of the methods were evaluated by comparing results for total arsenic and As(III), As(V), DMA, and MMA concentrations in ground water, AMD, and surface water. Seventy-one ground-water, 10 AMD, and 24 surface-water samples were analyzed. Concentrations in ground-water samples reached 720 ug-As/L for As(III) and 1080 ug-As/L for As(V); AMD samples reached 12800 ug-As/L for As(III) and 7050 ug-As/L for As(V); and surface-water samples reached 5 ug-As/L for As(III) and As(V). Inorganic arsenic species distribution in the samples ranged from 0 to 90 percent As(III). DMA and MMA were present only in surface-water samples from agricultural areas where the herbicide monosodium methylarsonate was applied; concentrations never exceeded 6 ug-As/L. Statistical analyses indicated that the difference between As(III) and As(V) concentrations for samples preserved with EDTA in opaque bottles and field-speciation results were analytically insignificant at the 95-percent confidence interval. There was no significant difference among the methods tested for total arsenic concentration. Percentage recovery for field samples spiked at 50 ug-As/L and analyzed by the laboratory-speciation method (n=2) ranged from 82 to 100 percent for As(III), 97 to 102 percent for As(V), 90 to 104 percent for DMA, and 81 to 96 percent for MMA; recoveries for samples spiked at 100 ug-As/L and analyzed by the field-speciation method ranged from 102 to 107 percent for As(III) and 105 to 106 percent for As(V). Laboratory-speciation results for Environment Canada reference material SLRS-2 closely matched reported concentrations. Laboratory-speciation metho

  10. Mosquito Control Techniques Developed for the US Military

    USDA-ARS?s Scientific Manuscript database

    The USDA developed and field tested new techniques to reduce the risk to deployed military troops from vector-borne diseases. Some of the methods developed included (1) novel military personal protection methods, (2) barrier treatments of artificial materials and natural vegetation, and (3) ground a...

  11. A novel 3D deformation measurement method under optical microscope for micro-scale bulge-test

    NASA Astrophysics Data System (ADS)

    Wu, Dan; Xie, Huimin

    2017-11-01

    A micro-scale 3D deformation measurement method combined with optical microscope is proposed in this paper. The method is based on gratings and phase shifting algorithm. By recording the grating images before and after deformation from two symmetrical angles and calculating the phases of the grating patterns, the 3D deformation field of the specimen can be extracted from the phases of the grating patterns. The proposed method was applied to the micro-scale bulge test. A micro-scale thermal/mechanical coupling bulge-test apparatus matched with the super-depth microscope was exploited. With the gratings fabricated onto the film, the deformed morphology of the bulged film was measured reliably. The experimental results show that the proposed method and the exploited bulge-test apparatus can be used to characterize the thermal/mechanical properties of the films at micro-scale successfully.

  12. Development of an autodissemination strategy for the deployment of novel control agents targeting the common malaria mosquito, Anopheles quadrimaculatus say (Diptera: Culicidae).

    PubMed

    Swale, Daniel R; Li, Zhilin; Kraft, Jake Z; Healy, Kristen; Liu, Mei; David, Connie M; Liu, Zhijun; Foil, Lane D

    2018-04-01

    The reduced efficacy of current Anopheline mosquito control methods underscores the need to develop new methods of control that exploit unique target sites and/or utilizes novel deployment methods. Autodissemination methodologies using insect growth regulators (IGRs) is growing in interest and has been shown to be effective at controlling Aedes mosquitoes in semi-field and field environments, yet little information exists for Anopheline mosquitoes. Therefore, we tested the hypothesis that female-driven autodissemination of an IGR combined with a new mechanism of action insecticide (Kir channel inhibitor) could be employed to reduce Anopheline populations. We studied the ability of three IGRs to be transferred to the larval habitat during oviposition in laboratory and semi-field environments. Adult mosquitoes were exposed to the chemicals for 4 hours immediately after blood feeding and efficacy was tested using classical methodologies, including adult emergence inhibition and High Performance Liquid Chromatography (HPLC). A complete autodissemination design was tested in a semi-field environment. Larval survivability and adult emergence were significantly reduced in habitats that were visited by novaluron treated adults, but no statistical differences were observed with pyriproxyfen or triflumuron. These data suggested novaluron, but not pyriproxyfen or triflumuron, was horizontally transferred from the adult mosquito to the larval habitat during oviposition. HPLC studies supported the toxicity data and showed that novaluron was present in the majority of larval habitats, suggesting that novaluron can be horizontally transferred by Anopheles quadrimaculatus. Importantly, the combination of novaluron and the Kir channel inhibitor, VU041, was capable of reducing adult and larval populations in semi-field environments. Novaluron can be transferred to the adult at a greater efficacy and/or is not degraded as quickly during the gonotropic cycle when compared to pyriproxyfen or triflumuron. Pending field confirmation, autodissemination approaches with novaluron may be a suitable tool to manage Anopheles populations.

  13. Incidental Testicular Irradiation From Prostate IMRT: It All Adds Up

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    King, Christopher R., E-mail: crking@stanford.ed; Maxim, Peter G.; Hsu, Annie

    Purpose: To identify the technical aspects of image-guided intensity-modulated radiation therapy (IMRT) for localized prostate cancer that could result in a clinically meaningful incidental dose to the testes. Methods and Materials: We examined three sources that contribute incidental dose to the testes, namely, from internal photon scattering from IMRT small field and large pelvic nodal fields with 6 or 15 MV, from neutrons when >10-MV photons are used, and from daily image-guided fiducial-based portal imaging. Using clinical data from 10 patients who received IMRT for prostate cancer, and thermo-luminescent dosimeter measurements in phantom, we estimated the dose to the testesmore » from each of these sources. Results: A mean testicular dose of 172 and 220 cGy results from internal photon scatter for pelvic nodal fields and 68 and 93 cGy for prostate-only fields, for 6- and 15-MV energies, respectively. For 15-MV photon energies, the mean testicular dose from neutrons is 60 cGy for pelvic fields and 31 cGy for prostate-only fields. From daily portal MV image guidance, the testes-in-field mean dose is 350 cGy, whereas the testes-out-of-field scatter dose is 16 cGy. Dosimetric comparisons between IMRT using 6-MV and 15-MV photon energies are not significantly different. Worst-case scenarios can potentially deliver cumulative incidental mean testicular doses of 630 cGy, whereas best-case scenarios can deliver only 84 cGy. Conclusions: Incidental dose to the testes from prostate IMRT can be minimized by opting to restrict the use of elective pelvic nodal fields, by choosing photon energies <10 MV, and by using the smallest port sizes necessary for daily image guidance.« less

  14. Sunglasses with thick temples and frame constrict temporal visual field.

    PubMed

    Denion, Eric; Dugué, Audrey Emmanuelle; Augy, Sylvain; Coffin-Pichonnet, Sophie; Mouriaux, Frédéric

    2013-12-01

    Our aim was to compare the impact of two types of sunglasses on visual field and glare: one ("thick sunglasses") with a thick plastic frame and wide temples and one ("thin sunglasses") with a thin metal frame and thin temples. Using the Goldmann perimeter, visual field surface areas (cm²) were calculated as projections on a 30-cm virtual cupola. A V4 test object was used, from seen to unseen, in 15 healthy volunteers in the primary position of gaze ("base visual field"), then allowing eye motion ("eye motion visual field") without glasses, then with "thin sunglasses," followed by "thick sunglasses." Visual field surface area differences greater than the 14% reproducibility error of the method and having a p < 0.05 were considered significant. A glare test was done using a surgical lighting system pointed at the eye(s) at different incidence angles. No significant "base visual field" or "eye motion visual field" surface area variations were noted when comparing tests done without glasses and with the "thin sunglasses." In contrast, a 22% "eye motion visual field" surface area decrease (p < 0.001) was noted when comparing tests done without glasses and with "thick sunglasses." This decrease was most severe in the temporal quadrant (-33%; p < 0.001). All subjects reported less lateral glare with the "thick sunglasses" than with the "thin sunglasses" (p < 0.001). The better protection from lateral glare offered by "thick sunglasses" is offset by the much poorer ability to use lateral space exploration; this results in a loss of most, if not all, of the additional visual field gained through eye motion.

  15. SU-F-T-472: Validation of Absolute Dose Measurements for MR-IGRT With and Without Magnetic Field

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Green, O; Li, H; Goddu, S

    Purpose: To validate absolute dose measurements for a MR-IGRT system without presence of the magnetic field. Methods: The standard method (AAPM’s TG-51) of absolute dose measurement with ionization chambers was tested with and without the presence of the magnetic field for a clinical 0.32-T Co-60 MR-IGRT system. Two ionization chambers were used - the Standard Imaging (Madison, WI) A18 (0.123 cc) and the PTW (Freiburg, Germany). A previously reported Monte Carlo simulation suggested a difference on the order of 0.5% for dose measured with and without the presence of the magnetic field, but testing this was not possible until anmore » engineering solution to allow the radiation system to be used without the nominal magnetic field was found. A previously identified effect of orientation in the magnetic field was also tested by placing the chamber either parallel or perpendicular to the field and irradiating from two opposing angles (90 and 270). Finally, the Imaging and Radiation Oncology Core provided OSLD detectors for five irradiations each with and without the field - with two heads at both 0 and 90 degrees, and one head at 90 degrees only as it doesn’t reach 0 (IEC convention). Results: For the TG-51 comparison, expected dose was obtained by decaying values measured at the time of source installation. The average measured difference was 0.4%±0.12% for A18 and 0.06%±0.15% for Farmer chamber. There was minimal (0.3%) orientation dependence without the magnetic field for the A18 chamber, while previous measurements with the magnetic field had a deviation of 3.2% with chamber perpendicular to magnetic field. Results reported by IROC for the OSLDs with and without the field had a maximum difference of 2%. Conclusion: Accurate absolute dosimetry was verified by measurement under the same conditions with and without the magnetic field for both ionization chambers and independently-verifiable OSLDs.« less

  16. Evaluation of hemifield sector analysis protocol in multifocal visual evoked potential objective perimetry for the diagnosis and early detection of glaucomatous field defects.

    PubMed

    Mousa, Mohammad F; Cubbidge, Robert P; Al-Mansouri, Fatima; Bener, Abdulbari

    2014-02-01

    Multifocal visual evoked potential (mfVEP) is a newly introduced method used for objective visual field assessment. Several analysis protocols have been tested to identify early visual field losses in glaucoma patients using the mfVEP technique, some were successful in detection of field defects, which were comparable to the standard automated perimetry (SAP) visual field assessment, and others were not very informative and needed more adjustment and research work. In this study we implemented a novel analysis approach and evaluated its validity and whether it could be used effectively for early detection of visual field defects in glaucoma. Three groups were tested in this study; normal controls (38 eyes), glaucoma patients (36 eyes) and glaucoma suspect patients (38 eyes). All subjects had a two standard Humphrey field analyzer (HFA) test 24-2 and a single mfVEP test undertaken in one session. Analysis of the mfVEP results was done using the new analysis protocol; the hemifield sector analysis (HSA) protocol. Analysis of the HFA was done using the standard grading system. Analysis of mfVEP results showed that there was a statistically significant difference between the three groups in the mean signal to noise ratio (ANOVA test, p < 0.001 with a 95% confidence interval). The difference between superior and inferior hemispheres in all subjects were statistically significant in the glaucoma patient group in all 11 sectors (t-test, p < 0.001), partially significant in 5 / 11 (t-test, p < 0.01), and no statistical difference in most sectors of the normal group (1 / 11 sectors was significant, t-test, p < 0.9). Sensitivity and specificity of the HSA protocol in detecting glaucoma was 97% and 86%, respectively, and for glaucoma suspect patients the values were 89% and 79%, respectively. The new HSA protocol used in the mfVEP testing can be applied to detect glaucomatous visual field defects in both glaucoma and glaucoma suspect patients. Using this protocol can provide information about focal visual field differences across the horizontal midline, which can be utilized to differentiate between glaucoma and normal subjects. Sensitivity and specificity of the mfVEP test showed very promising results and correlated with other anatomical changes in glaucoma field loss.

  17. Nonlocal interactions in color perception: nonlinear processing of chromatic signals from remote inducers.

    PubMed

    Wachtler, T; Albright, T D; Sejnowski, T J

    2001-05-01

    The perceived color of an object depends on the chromaticity of its immediate background. But color appearance is also influenced by remote chromaticities. To quantify these influences, the effects of remote color fields on the appearance of a fixated 2 degrees test field were measured using a forced-choice method. Changes in the appearance of the test field were induced by chromaticity changes of the background and of 2 degrees color fields not adjacent to the test field. The appearance changes induced by the color of the background corresponded to a fraction of between 0.5 and 0.95 of the cone contrast of the background change, depending on the observer. The magnitude of induction by the background color was modulated on average by 7.6% by chromaticity changes in the remote color fields. Chromaticity changes in the remote fields had virtually no inducing effect when they occurred without a change in background color. The spatial range of these chromatic interactions extended over at least 10 degrees from the fovea. They were established within the first few hundred milliseconds after the change of background color and depended only weakly on the number of inducing fields. These results may be interpreted as reflecting rapid chromatic interactions that support robustness of color vision under changing viewing conditions.

  18. A magnetic flux leakage and magnetostrictive guided wave hybrid transducer for detecting bridge cables.

    PubMed

    Xu, Jiang; Wu, Xinjun; Cheng, Cheng; Ben, Anran

    2012-01-01

    Condition assessment of cables has gained considerable attention for the bridge safety. A magnetic flux leakage and magnetostrictive guided wave hybrid transducer is provided to inspect bridge cables. The similarities and differences between the two methods are investigated. The hybrid transducer for bridge cables consists of an aluminum framework, climbing modules, embedded magnetizers and a ribbon coil. The static axial magnetic field provided by the magnetizers meets the needs of the magnetic flux leakage testing and the magnetostrictive guided wave testing. The magnetizers also provide the attraction for the climbing modules. In the magnetic flux leakage testing for the free length of cable, the coil induces the axial leakage magnetic field. In the magnetostrictive guided wave testing for the anchorage zone, the coil provides a pulse high power variational magnetic field for generating guided waves; the coil induces the magnetic field variation for receiving guided waves. The experimental results show that the transducer with the corresponding inspection system could be applied to detect the broken wires in the free length and in the anchorage zone of bridge cables.

  19. A Magnetic Flux Leakage and Magnetostrictive Guided Wave Hybrid Transducer for Detecting Bridge Cables

    PubMed Central

    Xu, Jiang; Wu, Xinjun; Cheng, Cheng; Ben, Anran

    2012-01-01

    Condition assessment of cables has gained considerable attention for the bridge safety. A magnetic flux leakage and magnetostrictive guided wave hybrid transducer is provided to inspect bridge cables. The similarities and differences between the two methods are investigated. The hybrid transducer for bridge cables consists of an aluminum framework, climbing modules, embedded magnetizers and a ribbon coil. The static axial magnetic field provided by the magnetizers meets the needs of the magnetic flux leakage testing and the magnetostrictive guided wave testing. The magnetizers also provide the attraction for the climbing modules. In the magnetic flux leakage testing for the free length of cable, the coil induces the axial leakage magnetic field. In the magnetostrictive guided wave testing for the anchorage zone, the coil provides a pulse high power variational magnetic field for generating guided waves; the coil induces the magnetic field variation for receiving guided waves. The experimental results show that the transducer with the corresponding inspection system could be applied to detect the broken wires in the free length and in the anchorage zone of bridge cables. PMID:22368483

  20. Passive shimming of a superconducting magnet using the L1-norm regularized least square algorithm.

    PubMed

    Kong, Xia; Zhu, Minhua; Xia, Ling; Wang, Qiuliang; Li, Yi; Zhu, Xuchen; Liu, Feng; Crozier, Stuart

    2016-02-01

    The uniformity of the static magnetic field B0 is of prime importance for an MRI system. The passive shimming technique is usually applied to improve the uniformity of the static field by optimizing the layout of a series of steel shims. The steel pieces are fixed in the drawers in the inner bore of the superconducting magnet, and produce a magnetizing field in the imaging region to compensate for the inhomogeneity of the B0 field. In practice, the total mass of steel used for shimming should be minimized, in addition to the field uniformity requirement. This is because the presence of steel shims may introduce a thermal stability problem. The passive shimming procedure is typically realized using the linear programming (LP) method. The LP approach however, is generally slow and also has difficulty balancing the field quality and the total amount of steel for shimming. In this paper, we have developed a new algorithm that is better able to balance the dual constraints of field uniformity and the total mass of the shims. The least square method is used to minimize the magnetic field inhomogeneity over the imaging surface with the total mass of steel being controlled by an L1-norm based constraint. The proposed algorithm has been tested with practical field data, and the results show that, with similar computational cost and mass of shim material, the new algorithm achieves superior field uniformity (43% better for the test case) compared with the conventional linear programming approach. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. [Does dark field microscopy according to Enderlein allow for cancer diagnosis? A prospective study].

    PubMed

    El-Safadi, Samer; Tinneberg, Hans-Rudolf; von Georgi, Richard; Münstedt, Karsten; Brück, Friede

    2005-06-01

    Dark field microscopy according to Enderlin claims to be able to detect forthcoming or beginning cancer at an early stage through minute abnormalities in the blood. In Germany and the USA, this method is used by an increasing number of physicians and health practitioners (non-medically qualified complementary practitioners), because this easy test seems to give important information about patients' health status. Can dark field microscopy reliably detect cancer? In the course of a prospective study on iridology, blood samples were drawn for dark field microscopy in 110 patients. A health practitioner with several years of training in the field carried out the examination without prior information about the patients. Out of 12 patients with present tumor metastasis as confirmed by radiological methods (CT, MRI or ultra-sound) 3 were correctly identified. Analysis of sensitivity (0.25), specificity (0.64), positive (0.09) and negative (0.85) predictive values revealed unsatisfactory results. Dark field micoroscopy does not seem to reliably detect the presence of cancer. Clinical use of the method can therefore not be recommended until future studies are conducted.

  2. Field Science Ethnography: Methods For Systematic Observation on an Expedition

    NASA Technical Reports Server (NTRS)

    Clancey, William J.; Clancy, Daniel (Technical Monitor)

    2001-01-01

    The Haughton-Mars expedition is a multidisciplinary project, exploring an impact crater in an extreme environment to determine how people might live and work on Mars. The expedition seeks to understand and field test Mars facilities, crew roles, operations, and computer tools. I combine an ethnographic approach to establish a baseline understanding of how scientists prefer to live and work when relatively unemcumbered, with a participatory design approach of experimenting with procedures and tools in the context of use. This paper focuses on field methods for systematically recording and analyzing the expedition's activities. Systematic photography and time-lapse video are combined with concept mapping to organize and present information. This hybrid approach is generally applicable to the study of modern field expeditions having a dozen or more multidisciplinary participants, spread over a large terrain during multiple field seasons.

  3. Internal field distribution of a radially inhomogeneous droplet illuminated by an arbitrary shaped beam

    NASA Astrophysics Data System (ADS)

    Wang, Jia Jie; Wriedt, Thomas; Han, Yi Ping; Mädler, Lutz; Jiao, Yong Chang

    2018-05-01

    Light scattering of a radially inhomogeneous droplet, which is modeled by a multilayered sphere, is investigated within the framework of Generalized Lorenz-Mie Theory (GLMT), with particular efforts devoted to the analysis of the internal field distribution in the cases of shaped beam illumination. To circumvent numerical difficulties in the computation of internal field for an absorbing/non-absorbing droplet with pretty large size parameter, a recursive algorithm is proposed by reformulation of the equations for the expansion coefficients. Two approaches are proposed for the prediction of the internal field distribution, namely a rigorous method and an approximation method. The developed computer code is tested to be stable in a wide range of size parameters. Numerical computations are implemented to simulate the internal field distributions of a radially inhomogeneous droplet illuminated by a focused Gaussian beam.

  4. Could Magnetic Fields Affect the Circadian Clock Function of Cryptochromes? Testing the Basic Premise of the Cryptochrome Hypothesis (ELF Magnetic Fields).

    PubMed

    Vanderstraeten, Jacques; Burda, Hynek; Verschaeve, Luc; De Brouwer, Christophe

    2015-07-01

    It has been suggested that weak 50/60 Hz [extremely low frequency (ELF)] magnetic fields (MF) could affect circadian biorhythms by disrupting the clock function of cryptochromes (the "cryptochrome hypothesis," currently under study). That hypothesis is based on the premise that weak (Earth strength) static magnetic fields affect the redox balance of cryptochromes, thus possibly their signaling state as well. An appropriate method for testing this postulate could be real time or short-term study of the circadian clock function of retinal cryptochromes under exposure to the static field intensities that elicit the largest redox changes (maximal "low field" and "high field" effects, respectively) compared to zero field. Positive results might encourage further study of the cryptochrome hypothesis itself. However, they would indicate the need for performing a similar study, this time comparing the effects of only slight intensity changes (low field range) in order to explore the possible role of the proximity of metal structures and furniture as a confounder under the cryptochrome hypothesis.

  5. The in-situ decontamination of sand and gravel aquifers by chemically enhanced solubilization of multiple-compound DNAPLs with surfactant solutions: Phase 1 -- Laboratory and pilot field-scale testing and Phase 2 -- Solubilization test and partitioning and interwell tracer tests. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1997-10-24

    Laboratory, numerical simulation, and field studies have been conducted to assess the potential use of micellar-surfactant solutions to solubilize chlorinated solvents contaminating sand and gravel aquifers. Ninety-nine surfactants were screened for their ability to solubilize trichloroethene (TCE), perchloroethylene (PCE), and carbon tetrachloride (CTET). The field test was conducted in the alluvial aquifer which is located 20 to 30 meters beneath a vapor degreasing operation at Paducah Gaseous Diffusion Plant. This aquifer has become contaminated with TCE due to leakage of perhaps 40,000 liters of TCE, which has generated a plume of dissolved TCE extending throughout an area of approximately 3more » km{sup 2} in the aquifer. Most of the TCE is believed to be present in the overlying lacustrine deposits and in the aquifer itself as a dense, non-aqueous phase liquid, or DNAPL. The objective of the field test was to assess the efficacy of the surfactant for in situ TCE solubilization. Although the test demonstrated that sorbitan monooleate was unsuitable as a solubilizer in this aquifer, the single-well test was demonstrated to be a viable method for the in situ testing of surfactants or cosolvents prior to proceeding to full-scale remediation.« less

  6. Validation of Methods to Predict Vibration of a Panel in the Near Field of a Hot Supersonic Rocket Plume

    NASA Technical Reports Server (NTRS)

    Bremner, P. G.; Blelloch, P. A.; Hutchings, A.; Shah, P.; Streett, C. L.; Larsen, C. E.

    2011-01-01

    This paper describes the measurement and analysis of surface fluctuating pressure level (FPL) data and vibration data from a plume impingement aero-acoustic and vibration (PIAAV) test to validate NASA s physics-based modeling methods for prediction of panel vibration in the near field of a hot supersonic rocket plume. For this test - reported more fully in a companion paper by Osterholt & Knox at 26th Aerospace Testing Seminar, 2011 - the flexible panel was located 2.4 nozzle diameters from the plume centerline and 4.3 nozzle diameters downstream from the nozzle exit. The FPL loading is analyzed in terms of its auto spectrum, its cross spectrum, its spatial correlation parameters and its statistical properties. The panel vibration data is used to estimate the in-situ damping under plume FPL loading conditions and to validate both finite element analysis (FEA) and statistical energy analysis (SEA) methods for prediction of panel response. An assessment is also made of the effects of non-linearity in the panel elasticity.

  7. An Empirical Non-TNT Approach to Launch Vehicle Explosion Modeling

    NASA Technical Reports Server (NTRS)

    Blackwood, James M.; Skinner, Troy; Richardson, Erin H.; Bangham, Michal E.

    2015-01-01

    In an effort to increase crew survivability from catastrophic explosions of Launch Vehicles (LV), a study was conducted to determine the best method for predicting LV explosion environments in the near field. After reviewing such methods as TNT equivalence, Vapor Cloud Explosion (VCE) theory, and Computational Fluid Dynamics (CFD), it was determined that the best approach for this study was to assemble all available empirical data from full scale launch vehicle explosion tests and accidents. Approximately 25 accidents or full-scale tests were found that had some amount of measured blast wave, thermal, or fragment explosion environment characteristics. Blast wave overpressure was found to be much lower in the near field than predicted by most TNT equivalence methods. Additionally, fragments tended to be larger, fewer, and slower than expected if the driving force was from a high explosive type event. In light of these discoveries, a simple model for cryogenic rocket explosions is presented. Predictions from this model encompass all known applicable full scale launch vehicle explosion data. Finally, a brief description of on-going analysis and testing to further refine the launch vehicle explosion environment is discussed.

  8. Design and analysis of the federal aviation administration next generation fire test burner

    NASA Astrophysics Data System (ADS)

    Ochs, Robert Ian

    The United States Federal Aviation Administration makes use of threat-based fire test methods for the certification of aircraft cabin materials to enhance the level of safety in the event of an in-flight or post-crash fire on a transport airplane. The global nature of the aviation industry results in these test methods being performed at hundreds of laboratories around the world; in some cases testing identical materials at multiple labs but yielding different results. Maintenance of this standard for an elevated level of safety requires that the test methods be as well defined as possible, necessitating a comprehensive understanding of critical test method parameters. The tests have evolved from simple Bunsen burner material tests to larger, more complicated apparatuses, requiring greater understanding of the device for proper application. The FAA specifies a modified home heating oil burner to simulate the effects of large, intense fires for testing of aircraft seat cushions, cargo compartment liners, power plant components, and thermal acoustic insulation. Recently, the FAA has developed a Next Generation (NexGen) Fire Test burner to replace the original oil burner that has become commercially unavailable. The NexGen burner design is based on the original oil burner but with more precise control of the air and fuel flow rates with the addition of a sonic nozzle and a pressurized fuel system. Knowledge of the fundamental flow properties created by various burner configurations is desired to develop an updated and standardized burner configuration for use around the world for aircraft materials fire testing and airplane certification. To that end, the NexGen fire test burner was analyzed with Particle Image Velocimetry (PIV) to resolve the non-reacting exit flow field and determine the influence of the configuration of burner components. The correlation between the measured flow fields and the standard burner performance metrics of flame temperature and burnthrough time was studied. Potential design improvements were also evaluated that could simplify burner set up and operation.

  9. Recover Act. Verification of Geothermal Tracer Methods in Highly Constrained Field Experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Becker, Matthew W.

    2014-05-16

    The prediction of the geothermal system efficiency is strong linked to the character of the flow system that connects injector and producer wells. If water flow develops channels or “short circuiting” between injection and extraction wells thermal sweep is poor and much of the reservoir is left untapped. The purpose of this project was to understand how channelized flow develops in fracture geothermal reservoirs and how it can be measured in the field. We explored two methods of assessing channelization: hydraulic connectivity tests and tracer tests. These methods were tested at a field site using two verification methods: ground penetratingmore » radar (GPR) images of saline tracer and heat transfer measurements using distributed temperature sensing (DTS). The field site for these studies was the Altona Flat Fractured Rock Research Site located in northeastern New York State. Altona Flat Rock is an experimental site considered a geologic analog for some geothermal reservoirs given its low matrix porosity. Because soil overburden is thin, it provided unique access to saturated bedrock fractures and the ability image using GPR which does not effectively penetrate most soils. Five boreholes were drilled in a “five spot” pattern covering 100 m2 and hydraulically isolated in a single bedding plane fracture. This simple system allowed a complete characterization of the fracture. Nine small diameter boreholes were drilled from the surface to just above the fracture to allow the measurement of heat transfer between the fracture and the rock matrix. The focus of the hydraulic investigation was periodic hydraulic testing. In such tests, rather than pumping or injection in a well at a constant rate, flow is varied to produce an oscillating pressure signal. This pressure signal is sensed in other wells and the attenuation and phase lag between the source and receptor is an indication of hydraulic connection. We found that these tests were much more effective than constant pumping tests in identifying a poorly connected well. As a result, we were able to predict which well pairs would demonstrate channelized flow. The focus of the tracer investigation was multi-ionic tests. In multi-ionic tests several ionic tracers are injected simultaneously and the detected in a nearby pumping well. The time history of concentration, or breakthrough curve, will show a separation of the tracers. Anionic tracers travel with the water but cationic tracer undergo chemical exchange with cations on the surface of the rock. The degree of separation is indicative of the surface area exposed to the tracer. Consequently, flow channelization will tend to decrease the separation in the breakthrough. Estimation of specific surface area (the ration of fracture surface area to formation volume) is performed through matching the breakthrough curve with a transport model. We found that the tracer estimates of surface area were confirmed the prediction of channelized flow between well pairs produced by the periodic hydraulic tests. To confirm that the hydraulic and tracer tests were correctly predicting channelize flow, we imaged the flow field using surface GPR. Saline water was injected between the well pairs which produced a change in the amplitude and phase of the reflected radar signal. A map was produced of the migration of saline tracer from these tests which qualitatively confirmed the flow channelization predicted by the hydraulic and tracer tests. The resolution of the GPR was insufficient to quantitatively estimate swept surface area, however. Surface GPR is not applicable in typical geothermal fields because the penetration depths do not exceed 10’s of meters. Nevertheless, the method of using of phase to measure electrical conductivity and the assessment of antennae polarization represent a significant advancement in the field of surface GPR. The effect of flow character on fracture / rock thermal exchange was evaluated using heated water as a tracer. Water elevated 30 degrees C above the formation water was circulated between two wells pairs. One well pair had been identified in hydraulic and tracer testing as well connected and the other poorly connected. Temperature rise was measured in the adjacent rock matrix using coiled fiber optic cable interrogated for temperature using a DTS. This experimental design produced over 4000 temperature measurements every hour. We found that heat transfer between the fracture and the rock matrix was highly impacted by the character of the flow field. The strongly connected wells which had demonstrated flow channelization produced heat rise in a much more limited area than the more poorly connected wells. In addition, the heat increase followed the natural permeability of the fracture rather than the induced flow field. The primary findings of this work are (1) even in a single relatively planar fracture, the flow field can be highly heterogeneous and exhibit flow channeling, (2) channeling results from a combination of fracture permeability structure and the induced flow field, and (3) flow channeling leads to reduced heat transfer. Multi-ionic tracers effectively estimate relative surface area but an estimate of ion-exchange coefficients are necessary to provide an absolute measure of specific surface area. Periodic hydraulic tests also proved a relative indicator of connectivity but cannot prove an absolute measure of specific surface area.« less

  10. Analytical method for establishing indentation rolling resistance

    NASA Astrophysics Data System (ADS)

    Gładysiewicz, Lech; Konieczna, Martyna

    2018-01-01

    Belt conveyors are highly reliable machines able to work in special operating conditions. Harsh environment, long distance of transporting and great mass of transported martials are cause of high energy usage. That is why research in the field of belt conveyor transportation nowadays focuses on reducing the power consumption without lowering their efficiency. In this paper, previous methods for testing rolling resistance are described, and new method designed by authors was presented. New method of testing rolling resistance is quite simple and inexpensive. Moreover it allows to conduct the experimental tests of the impact of different parameters on the value of indentation rolling resistance such as core design, cover thickness, ambient temperature, idler travel frequency, or load value as well. Finally results of tests of relationship between rolling resistance and idler travel frequency and between rolling resistance and idler travel speed was presented.

  11. Duct Leakage Repeatability Testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walker, Iain; Sherman, Max

    2014-08-01

    The purpose of this report is to evaluate the repeatability of the three most significant measurement techniques for duct leakage using data from the literature and recently obtained field data. We will also briefly discuss the first two factors. The main question to be answered by this study is to determine if differences in the repeatability of these tests methods is sufficient to indicate that any of these methods is so poor that it should be excluded from consideration as an allowed procedure in codes and standards. The three duct leak measurement methods assessed in this report are the twomore » duct pressurization methods that are commonly used by many practitioners and the DeltaQ technique. These are methods B, C and A, respectively of the ASTM E1554 standard. Although it would be useful to evaluate other duct leak test methods, this study focused on those test methods that are commonly used and are required in various test standards, such as BPI (2010), RESNET (2014), ASHRAE 62.2 (2013), California Title 24 (CEC 2012), DOE Weatherization and many other energy efficiency programs.« less

  12. Preservation Methods Differ in Fecal Microbiome Stability, Affecting Suitability for Field Studies.

    PubMed

    Song, Se Jin; Amir, Amnon; Metcalf, Jessica L; Amato, Katherine R; Xu, Zhenjiang Zech; Humphrey, Greg; Knight, Rob

    2016-01-01

    Immediate freezing at -20°C or below has been considered the gold standard for microbiome preservation, yet this approach is not feasible for many field studies, ranging from anthropology to wildlife conservation. Here we tested five methods for preserving human and dog fecal specimens for periods of up to 8 weeks, including such types of variation as freeze-thaw cycles and the high temperature fluctuations often encountered under field conditions. We found that three of the methods-95% ethanol, FTA cards, and the OMNIgene Gut kit-can preserve samples sufficiently well at ambient temperatures such that differences at 8 weeks are comparable to differences among technical replicates. However, even the worst methods, including those with no fixative, were able to reveal microbiome differences between species at 8 weeks and between individuals after a week, allowing meta-analyses of samples collected using various methods when the effect of interest is expected to be larger than interindividual variation (although use of a single method within a study is strongly recommended to reduce batch effects). Encouragingly for FTA cards, the differences caused by this method are systematic and can be detrended. As in other studies, we strongly caution against the use of 70% ethanol. The results, spanning 15 individuals and over 1,200 samples, provide our most comprehensive view to date of storage effects on stool and provide a paradigm for the future studies of other sample types that will be required to provide a global view of microbial diversity and its interaction among humans, animals, and the environment. IMPORTANCE Our study, spanning 15 individuals and over 1,200 samples, provides our most comprehensive view to date of storage and stabilization effects on stool. We tested five methods for preserving human and dog fecal specimens for periods of up to 8 weeks, including the types of variation often encountered under field conditions, such as freeze-thaw cycles and high temperature fluctuations. We show that several cost-effective methods provide excellent microbiome stability out to 8 weeks, opening up a range of field studies with humans and wildlife that would otherwise be cost-prohibitive.

  13. First annual report of the Botany Field Station

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berry, E.C.; Cline, J.F.

    This is the first annual report of the Botany Field Station No. 1. The location, layout and method of irrigating the station are described. The crops grown and their yields are given. Results of analyses for radioactivity are reported in tabular form. No evidence of radioactivity above accepted tolerance levels in foods was obtained for any of the crops tested. A plane table plot of the Field Station and photographs are included.

  14. Improving the spatial representation of soil properties and hydrology using topographically derived watershed model initialization processes

    NASA Astrophysics Data System (ADS)

    Easton, Z. M.; Fuka, D.; Collick, A.; Kleinman, P. J. A.; Auerbach, D.; Sommerlot, A.; Wagena, M. B.

    2015-12-01

    Topography exerts critical controls on many hydrologic, geomorphologic, and environmental biophysical processes. Unfortunately many watershed modeling systems use topography only to define basin boundaries and stream channels and do not explicitly account for the topographic controls on processes such as soil genesis, soil moisture distributions and hydrological response. We develop and demonstrate a method that uses topography to spatially adjust soil morphological and soil hydrological attributes [soil texture, depth to the C-horizon, saturated conductivity, bulk density, porosity, and the field capacities at 33kpa (~ field capacity) and 1500kpa (~ wilting point) tensions]. In order to test the performance of the method the topographical adjusted soils and standard SSURGO soil (available at 1:20,000 scale) were overlaid on soil pedon pit data in the Grasslands Soil and Water Research Lab in Resiel, TX. The topographically adjusted soils exhibited significant correlations with measurements from the soil pits, while the SSURGO soil data showed almost no correlation to measured data. We also applied the method to the Grasslands Soil and Water Research watershed using the Soil and Water Assessment Tool (SWAT) model to 15 separate fields as a proxy to propagate changes in soil properties into field scale hydrological responses. Results of this test showed that the topographically adjusted soils resulted better model predictions of field runoff in 50% of the field, with the SSURGO soils preforming better in the remainder of the fields. However, the topographically adjusted soils generally predicted baseflow response more accurately, reflecting the influence of these soil properties on non-storm responses. These results indicate that adjusting soil properties based on topography can result in more accurate soil characterization and, in some cases improve model performance.

  15. Some Practical Solutions to Standard-Setting Problems: The Georgia Teacher Certification Test Experience.

    ERIC Educational Resources Information Center

    Cramer, Stephen E.

    A standard-setting procedure was developed for the Georgia Teacher Certification Testing Program as tests in 30 teaching fields were revised. A list of important characteristics of a standard-setting procedure was derived, drawing on the work of R. A. Berk (1986). The best method was found to be a highly formalized judgmental, empirical Angoff…

  16. Electrofracturing test system and method of determining material characteristics of electrofractured material samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bauer, Stephen J.; Glover, Steven F.; Pfeifle, Tom

    A device for electrofracturing a material sample and analyzing the material sample is disclosed. The device simulates an in situ electrofracturing environment so as to obtain electrofractured material characteristics representative of field applications while allowing permeability testing of the fractured sample under in situ conditions.

  17. Wide-Field InfraRed Survey Telescope (WFIRST) Slitless Spectrometer: Design, Prototype, and Results

    NASA Technical Reports Server (NTRS)

    Gong, Qian; Content, David; Dominguez, Margaret; Emmett, Thomas; Griesmann, Ulf; Hagopian, John; Kruk, Jeffrey; Marx, Catherine; Pasquale, Bert; Wallace, Thomas; hide

    2016-01-01

    The slitless spectrometer plays an important role in the Wide-Field InfraRed Survey Telescope (WFIRST) mission for the survey of emission-line galaxies. This will be an unprecedented very wide field, HST quality 3D survey of emission line galaxies. The concept of the compound grism as a slitless spectrometer has been presented previously. The presentation briefly discusses the challenges and solutions of the optical design, and recent specification updates, as well as a brief comparison between the prototype and the latest design. However, the emphasis of this paper is the progress of the grism prototype: the fabrication and test of the complicated diffractive optical elements and powered prism, as well as grism assembly alignment and testing. Especially how to use different tools and methods, such as IR phase shift and wavelength shift interferometry, to complete the element and assembly tests. The paper also presents very encouraging results from recent element tests to assembly tests. Finally we briefly touch the path forward plan to test the spectral characteristic, such as spectral resolution and response.

  18. Reconstructing the Initial Density Field of the Local Universe: Methods and Tests with Mock Catalogs

    NASA Astrophysics Data System (ADS)

    Wang, Huiyuan; Mo, H. J.; Yang, Xiaohu; van den Bosch, Frank C.

    2013-07-01

    Our research objective in this paper is to reconstruct an initial linear density field, which follows the multivariate Gaussian distribution with variances given by the linear power spectrum of the current cold dark matter model and evolves through gravitational instabilities to the present-day density field in the local universe. For this purpose, we develop a Hamiltonian Markov Chain Monte Carlo method to obtain the linear density field from a posterior probability function that consists of two components: a prior of a Gaussian density field with a given linear spectrum and a likelihood term that is given by the current density field. The present-day density field can be reconstructed from galaxy groups using the method developed in Wang et al. Using a realistic mock Sloan Digital Sky Survey DR7, obtained by populating dark matter halos in the Millennium simulation (MS) with galaxies, we show that our method can effectively and accurately recover both the amplitudes and phases of the initial, linear density field. To examine the accuracy of our method, we use N-body simulations to evolve these reconstructed initial conditions to the present day. The resimulated density field thus obtained accurately matches the original density field of the MS in the density range 0.3 \\lesssim \\rho /\\bar{\\rho } \\lesssim 20 without any significant bias. In particular, the Fourier phases of the resimulated density fields are tightly correlated with those of the original simulation down to a scale corresponding to a wavenumber of ~1 h Mpc-1, much smaller than the translinear scale, which corresponds to a wavenumber of ~0.15 h Mpc-1.

  19. Role of Microstructure in High Temperature Oxidation.

    DTIC Science & Technology

    1980-05-01

    Surface Prepartion Upon Oxidation ......... .................. 20 EXPERIMENTAL METHODS 21 Speciemen Preparation...angle sectioning method 26 Figure 3. Application of the test line upon the image of NiO scale to determine the number of the NiO grain boundary...of knowledge in this field was readily accounted for by extreme experimental difficulty in applying standard methods of microscopy to the thin

  20. Micromagnetic recording model of writer geometry effects at skew

    NASA Astrophysics Data System (ADS)

    Plumer, M. L.; Bozeman, S.; van Ek, J.; Michel, R. P.

    2006-04-01

    The effects of the pole-tip geometry at the air-bearing surface on perpendicular recording at a skew angle are examined through modeling and spin-stand test data. Head fields generated by the finite element method were used to record transitions within our previously described micromagnetic recording model. Write-field contours for a variety of square, rectangular, and trapezoidal pole shapes were evaluated to determine the impact of geometry on field contours. Comparing results for recorded track width, transition width, and media signal to noise ratio at 0° and 15° skew demonstrate the benefits of trapezoidal and reduced aspect-ratio pole shapes. Consistency between these modeled results and test data is demonstrated.

Top