'Towers in the Tempest' Computer Animation Submission
NASA Technical Reports Server (NTRS)
Shirah, Greg
2008-01-01
The following describes a computer animation that has been submitted to the ACM/SIGGRAPH 2008 computer graphics conference: 'Towers in the Tempest' clearly communicates recent scientific research into how hurricanes intensify. This intensification can be caused by a phenomenon called a 'hot tower.' For the first time, research meteorologists have run complex atmospheric simulations at a very fine temporal resolution of 3 minutes. Combining this simulation data with satellite observations enables detailed study of 'hot towers.' The science of 'hot towers' is described using: satellite observation data, conceptual illustrations, and a volumetric atmospheric simulation data. The movie starts by showing a 'hot tower' observed by NASA's Tropical Rainfall Measuring Mission (TRMM) spacecraft's three dimensional precipitation radar data of Hurricane Bonnie. Next, the dynamics of a hurricane and the formation of 'hot towers' are briefly explained using conceptual illustrations. Finally, volumetric cloud, wind, and vorticity data from a supercomputer simulation of Hurricane Bonnie are shown using volume techniques such as ray marching.
Summary of tower designs for large horizontal axis wind turbines
NASA Technical Reports Server (NTRS)
Frederick, G. R.; Savino, J. M.
1986-01-01
Towers for large horizontal axis wind turbines, machines with a rotor axis height above 30 meters and rated at more than 500 kW, have varied in configuration, materials of construction, type of construction, height, and stiffness. For example, the U.S. large HAWTs have utilized steel truss type towers and free-standing steel cylindrical towers. In Europe, the trend has been to use only free-standing and guyed cylindrical towers, but both steel and reinforced concrete have been used as materials of construction. These variations in materials of construction and type of construction reflect different engineering approaches to the design of cost effective towers for large HAWTs. Tower designs are the NASA/DOE Mod-5B presently being fabricated. Design goals and requirements that influence tower configuration, height and materials are discussed. In particular, experiences with United States large wind turbine towers are elucidated. Finally, current trends in tower designs for large HAWTs are highlighted.
25. BOILER HOUSE, LOOKING FROM THE NORTHEAST AT COAL CARS ...
25. BOILER HOUSE, LOOKING FROM THE NORTHEAST AT COAL CARS No. 9 & 5 (NOTE: COAL CONVEYOR RUNNING ABOVE THE CARS; THIS CONVEYOR ORIGINATES IN COAL TOWER No. 1 (WEST)) - Delaware County Electric Company, Chester Station, Delaware River at South end of Ward Street, Chester, Delaware County, PA
Wind turbine generator application places unique demands on tower design and materials
NASA Technical Reports Server (NTRS)
Kita, J. P.
1978-01-01
The most relevant contractual tower design requirements and goal for the Mod-1 tower are related to steel truss tower construction, cost-effective state-of-the-art design, a design life of 30 years, and maximum wind conditions of 120 mph at 30 feet elevation. The Mod-1 tower design approach was an iterative process. Static design loads were calculated and member sizes and overall geometry chosen with the use of finite element computer techniques. Initial tower dynamic characteristics were then combined with the dynamic properties of the other wind turbine components, and a series of complex dynamic computer programs were run to establish a dynamic load set and then a second tower design.
Credit WCT. Photographic copy of photograph, low level aerial view ...
Credit WCT. Photographic copy of photograph, low level aerial view of Test Stand "D," looking due south, after completion of Dd station installation in 1961. Note Test Stand "D" "neutralization pond" to immediate southeast of tower. A steel barrier north of and parallel to the Dd station separates fuel run tanks (on south side obscured from view) from oxidizer run tanks (on north side). Small Dj injector test stand is visible to the immediate left of oxidizer run tanks; it is oriented on a northeast/southwest diagonal to the Dd test station. The large tank to the north of the oxidizer run tanks (near center bottom of view) is an oxidizer storage tank for nitrogen tetroxide. Slender tanks to the northwest of the tower (lower right of view) contain high pressure nitrogen gas. A large vertical tank at the base of the tower contains distilled water for flushing propellant lines. (JPL negative no. 384-2997-B, 12 December 1961) - Jet Propulsion Laboratory Edwards Facility, Test Stand D, Edwards Air Force Base, Boron, Kern County, CA
NASA Astrophysics Data System (ADS)
Andrews, A. E.; Kort, E.; Hirsch, A.; Eluszkiewicz, J.; Nehrkorn, T.; Michalak, A. M.; Petron, G.; Frost, G. J.; Gurney, K. R.; Stohl, A.; Wofsy, S. C.; Angevine, W. M.; White, A. B.; Oltmans, S. J.; Montzka, S. A.; Tans, P. P.
2008-12-01
The NOAA Earth System Research Laboratory has been measuring CO2, CO and basic meteorology from a television transmitter tower outside of Waco, TX since 2001. Sample intakes are located at 30, 122 and 457 meters above ground level. From July through November 2006, O3 measurements were added at 9 and 457 magl to support the Texas Air Quality Study (TexAQS 2006). There are several large point sources and metropolitan areas in the vicinity of the tower with distinct chemical signatures. Here, we evaluate the extent to which the Stochastic Time Inverted Lagrangian Transport (STILT) model reproduces pollution events that were observed at the tower during summer and fall 2006. For this study, STILT is driven by customized output from the WRF model v2.2, which was run with a 2km nested grid surrounding the tower embedded in a 10km nest that covers most of the southern and eastern US and a 40km nest that includes all of North America. Inaccurate representation of atmospheric transport is a major source of error in inverse estimates of fluxes of CO2 and other gases, and we selected this period for in depth analysis in part because a dense network of radar profilers was deployed for TexAQS 2006. The radar profilers report wind and boundary layer height, which can be used to evaluate the fidelity of the simulated transport. STILT is a particle dispersion model that can be run either forward or backward in time, which allows us to compare the agreement between forward runs from individual pollution sources and backward runs from the tower. We will also quantitatively compare the STILT-WRF results with similar output from the FLEXPART particle dispersion model driven by high-resolution ECMWF meteorological fields. We will use several different emissions inventories to evaluate model-to-model differences and differences between modeled and observed pollution influences.
33 CFR 110.138 - Boston Harbor, Mass.
Code of Federal Regulations, 2012 CFR
2012-07-01
... line running due north from Old Harbor Buoy 4 to the shore line at City Point. (5) Explosives anchorage... beacon on top of the Boston Custom House tower; and thence to the point of beginning. (2) President Roads... adjacent land; on the east by a line between Castle Rocks Fog Signal Light and Old Harbor Shoal Buoy 2; on...
33 CFR 110.138 - Boston Harbor, Mass.
Code of Federal Regulations, 2013 CFR
2013-07-01
... line running due north from Old Harbor Buoy 4 to the shore line at City Point. (5) Explosives anchorage... beacon on top of the Boston Custom House tower; and thence to the point of beginning. (2) President Roads... adjacent land; on the east by a line between Castle Rocks Fog Signal Light and Old Harbor Shoal Buoy 2; on...
33 CFR 110.138 - Boston Harbor, Mass.
Code of Federal Regulations, 2014 CFR
2014-07-01
... line running due north from Old Harbor Buoy 4 to the shore line at City Point. (5) Explosives anchorage... beacon on top of the Boston Custom House tower; and thence to the point of beginning. (2) President Roads... adjacent land; on the east by a line between Castle Rocks Fog Signal Light and Old Harbor Shoal Buoy 2; on...
40 CFR 61.134 - Standard: Naphthalene processing, final coolers, and final-cooler cooling towers.
Code of Federal Regulations, 2012 CFR
2012-07-01
... POLLUTANTS National Emission Standard for Benzene Emissions from Coke By-Product Recovery Plants § 61.134... are allowed from naphthalene processing, final coolers and final-cooler cooling towers at coke by...
40 CFR 61.134 - Standard: Naphthalene processing, final coolers, and final-cooler cooling towers.
Code of Federal Regulations, 2014 CFR
2014-07-01
... POLLUTANTS National Emission Standard for Benzene Emissions from Coke By-Product Recovery Plants § 61.134... are allowed from naphthalene processing, final coolers and final-cooler cooling towers at coke by...
40 CFR 61.134 - Standard: Naphthalene processing, final coolers, and final-cooler cooling towers.
Code of Federal Regulations, 2013 CFR
2013-07-01
... POLLUTANTS National Emission Standard for Benzene Emissions from Coke By-Product Recovery Plants § 61.134... are allowed from naphthalene processing, final coolers and final-cooler cooling towers at coke by...
40 CFR 61.134 - Standard: Naphthalene processing, final coolers, and final-cooler cooling towers.
Code of Federal Regulations, 2011 CFR
2011-07-01
... POLLUTANTS National Emission Standard for Benzene Emissions from Coke By-Product Recovery Plants § 61.134... are allowed from naphthalene processing, final coolers and final-cooler cooling towers at coke by...
NASA Technical Reports Server (NTRS)
1984-01-01
The design, development and analysis of the 7.3 MW MOD-5A wind turbine generator is documented. Volume 3, book 1 describes the performance and characteristics of the MOD-5A wind turbine generator in its final configuration. Each subsystem - the rotor, drivetrain, nacelle, tower and foundation is described in detail.
40 CFR 61.134 - Standard: Naphthalene processing, final coolers, and final-cooler cooling towers.
Code of Federal Regulations, 2010 CFR
2010-07-01
... POLLUTANTS National Emission Standard for Benzene Emissions from Coke By-Product Recovery Plants § 61.134... are allowed from naphthalene processing, final coolers and final-cooler cooling towers at coke by-product recovery plants. ...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-26
... the New Airport Traffic Control Tower and Base Building at Cherry Capital Airport, Traverse City, MI... the New Airport Traffic Control Tower and Base Building at Cherry Capital Airport, Traverse City... Control Tower (ATCT) and Base Building at Cherry Capital Airport (TVC) in Traverse City, Michigan. The FAA...
77 FR 60919 - Tennessee: Final Authorization of State Hazardous Waste Management Program Revisions
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-05
...: Final Authorization of State Hazardous Waste Management Program Revisions AGENCY: Environmental..., Division of Solid Waste Management, 5th Floor, L & C Tower, 401 Church Street, Nashville, Tennessee 37243... RCRA hazardous waste management program. We granted authorization for changes to Tennessee's program on...
Simulation of a 5MW wind turbine in an atmospheric boundary layer
NASA Astrophysics Data System (ADS)
Meister, Konrad; Lutz, Thorsten; Krämer, Ewald
2014-12-01
This article presents detached eddy simulation (DES) results of a 5MW wind turbine in an unsteady atmospheric boundary layer. The evaluation performed in this article focuses on turbine blade loads as well as on the influence of atmospheric turbulence and tower on blade loads. Therefore, the turbulence transport of the atmospheric boundary layer to the turbine position is analyzed. To determine the influence of atmospheric turbulence on wind turbines the blade load spectrum is evaluated and compared to wind turbine simulation results with uniform inflow. Moreover, the influences of different frequency regimes and the tower on the blade loads are discussed. Finally, the normal force coefficient spectrum is analyzed at three different radial positions and the influence of tower and atmospheric turbulence is shown.
NASA Astrophysics Data System (ADS)
Boudreaux, R. D.; Metzger, C. E.; Macias, B. R.; Shirazi-Fard, Y.; Hogan, H. A.; Bloomfield, S. A.
2014-06-01
Astronauts on long duration missions continue to experience bone loss, as much as 1-2% each month, for up to 4.5 years after a mission. Mechanical loading of bone with exercise has been shown to increase bone formation, mass, and geometry. The aim of this study was to compare the efficacy of two exercise protocols during a period of reduced gravitational loading (1/6th body weight) in mice. Since muscle contractions via resistance exercise impart the largest physiological loads on the skeleton, we hypothesized that resistance training (via vertical tower climbing) would better protect against the deleterious musculoskeletal effects of reduced gravitational weight bearing when compared to endurance exercise (treadmill running). Young adult female BALB/cBYJ mice were randomly assigned to three groups: 1/6 g (G/6; n=6), 1/6 g with treadmill running (G/6+RUN; n=8), or 1/6 g with vertical tower climbing (G/6+CLB; n=9). Exercise was performed five times per week. Reduced weight bearing for 21 days was achieved through a novel harness suspension system. Treadmill velocity (12-20 m/min) and daily run time duration (32-51 min) increased incrementally throughout the study. Bone geometry and volumetric bone mineral density (vBMD) at proximal metaphysis and mid-diaphysis tibia were assessed by in vivo peripheral quantitative computed tomography (pQCT) on days 0 and 21 and standard dynamic histomorphometry was performed on undemineralized sections of the mid-diaphysis after tissue harvest. G/6 caused a significant decrease (P<0.001) in proximal tibia metaphysis total vBMD (-9.6%). These reductions of tibia metaphyseal vBMD in G/6 mice were mitigated in both G/6+RUN and G/6+CLB groups (P<0.05). After 21 days of G/6, we saw an absolute increase in tibia mid-diaphysis vBMD and in distal metaphysis femur vBMD in both G/6+RUN and G/6+CLB mice (P<0.05). Substantial increases in endocortical and periosteal mineralizing surface (MS/BS) at mid-diaphysis tibia in G/6+CLB demonstrate that bone formation can be increased even in the presence of reduced weight bearing. These data suggest that moderately vigorous endurance exercise and resistance training, through treadmill running or climb training mitigates decrements in vBMD during 21 days of reduced weight bearing. Consistent with our hypothesis, tower climb training, most pronounced in the tibia mid-diaphysis, provides a more potent osteogenic response compared to treadmill running.
Analysis of wind-resistant and stability for cable tower in cable-stayed bridge with four towers
NASA Astrophysics Data System (ADS)
Meng, Yangjun; Li, Can
2017-06-01
Wind speed time history simulation methods have been introduced first, especially the harmonic synthesis method introduced in detail. Second, taking Chishi bridge for example, choosing the particular sections, and combined with the design wind speed, three-component coefficient simulate analysis between -4°and 4°has been carry out with the Fluent software. The results show that drag coefficient reaches maximum when the attack Angle is 1°. According to measured wind speed samples,time history curves of wind speed at bridge deck and tower roof have been obtained,and wind-resistant time history analysis for No.5 tower has been carry out. Their results show that the dynamic coefficients are different with different calculation standard, especially transverse bending moment, pulsating crosswind load does not show a dynamic amplification effect.Under pulsating wind loads at bridge deck or tower roof, the maximum displacement at the top of the tower and the maximum stress at the bottom of the tower are within the allowable range. The transverse stiffness of tower is greater than that of the longitudinal stiffness, therefore wind-resistant analysis should give priority to the longitudinal direction. Dynamic coefficients are different with different standard, the maximum dynamic coefficient should be used for the pseudo-static analysis.Finally, the static stability of tower is analyzed with different load combinations, and the galloping stabilities of cable tower is proved.
Final Rule for Industrial Process Cooling Towers: Fact Sheet
Fact sheet concerning a final rule to reduce air toxics emissions from industrial process cooling towers. Air toxics are those pollutants known or suspected of causing cancer or other serious health effects.
90. PORTLAND FILTER FLOOR FROM SOUTHEAST. CYANIDE FEED TOWER TO ...
90. PORTLAND FILTER FLOOR FROM SOUTHEAST. CYANIDE FEED TOWER TO SUMP, LOWER RIGHT QUADRANT. DIAGONAL PIPE IN UPPER RIGHT IS AIR LINE TO AGITATORS. LAUNDER PARALLEL TO LEFT EDGE (FILLED WITH DEBRIS) RUNS FROM PRIMARY THICKENER No. 2 TO GOLD TANK No. 2. - Bald Mountain Gold Mill, Nevada Gulch at head of False Bottom Creek, Lead, Lawrence County, SD
169. PORTLAND FILTER FLOOR FROM SOUTHEAST. CYANIDE FEED TOWER TO ...
169. PORTLAND FILTER FLOOR FROM SOUTHEAST. CYANIDE FEED TOWER TO SUMP, LOWER RIGHT QUADRANT. DIAGONAL PIPE IN UPPER RIGHT IS AIR LINE TO AGITATORS. LAUNDER PARALLEL TO LEFT EDGE (FILLED WITH DEBRIS) RUNS FROM PRIMARY THICKENER No. 2 TO GOLD TANK No. 2 - Bald Mountain Gold Mill, Nevada Gulch at head of False Bottom Creek, Lead, Lawrence County, SD
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-15
... DEPARTMENT OF COMMERCE International Trade Administration [C-570-982] Utility Scale Wind Towers...''), the Department is issuing a countervailing duty order on utility scale wind towers (``wind towers..., 2012, the Department published the final determination in the countervailing duty investigation of wind...
2016-07-01
All Initial Designs for Final Fab Run Month 29 Masks and wafers prepared for Final Fab Run Month 30 Start of Final Fab Run Month 35 Completion of...Final Fab Run Month 36 Delivery of devices based on designs from other DEFYS performers Because of momentum from efforts prior to the start of...report (June 2016), our project is completed, with most tasks completed ahead of schedule. For example, the 3rd Fab Run started 5 months early and was
9. FACING NORTH, WATER POWER PENSTOCK RUNS RIGHT TO LEFT, ...
9. FACING NORTH, WATER POWER PENSTOCK RUNS RIGHT TO LEFT, ONE OF TWO DRAFT TUBES AT LOWER RIGHT. TOWERS, BUILDING CROSSWALKS, AND MILL NO. 2 IN BACKGROUND; DAM GATES TO LEFT. - Prattville Manufacturing Company, Number One, 242 South Court Street, Prattville, Autauga County, AL
NASA Astrophysics Data System (ADS)
Barman, K.; Dahlberg, J. A.; Meijer, S.
Hot-wire measurements of the velocity deficit in the wake behind the tower of a wind turbine are presented. The measurements were performed at one height and at three distances from the tower center when the turbine was not running. The low frequency noise caused by the passage of a turbine blade through the wake of the tower is calculated using wake data from the measurements. A comparision with noise emission measurements is included. The variation in blade loading and turbine power output caused by the wake are also calculated. Results show that wake deficits can be of the same order of magnitude as the freestream velocity.
Roemers, P; Mazzola, P N; De Deyn, P P; Bossers, W J; van Heuvelen, M J G; van der Zee, E A
2018-04-15
Voluntary strength training methods for rodents are necessary to investigate the effects of strength training on cognition and the brain. However, few voluntary methods are available. The current study tested functional and muscular effects of two novel voluntary strength training methods, burrowing (digging a substrate out of a tube) and unloaded tower climbing, in male C57Bl6 mice. To compare these two novel methods with existing exercise methods, resistance running and (non-resistance) running were included. Motor coordination, grip strength and muscle fatigue were measured at baseline, halfway through and near the end of a fourteen week exercise intervention. Endurance was measured by an incremental treadmill test after twelve weeks. Both burrowing and resistance running improved forelimb grip strength as compared to controls. Running and resistance running increased endurance in the treadmill test and improved motor skills as measured by the balance beam test. Post-mortem tissue analyses revealed that running and resistance running induced Soleus muscle hypertrophy and reduced epididymal fat mass. Tower climbing elicited no functional or muscular changes. As a voluntary strength exercise method, burrowing avoids the confounding effects of stress and positive reinforcers elicited in forced strength exercise methods. Compared to voluntary resistance running, burrowing likely reduces the contribution of aerobic exercise components. Burrowing qualifies as a suitable voluntary strength training method in mice. Furthermore, resistance running shares features of strength training and endurance (aerobic) exercise and should be considered a multi-modal aerobic-strength exercise method in mice. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
1983-01-01
Liquid diffusion masks and liquid dopants to replace the more expensive CVD SiO2 mask and gaseous diffusion processes were investigated. Silicon pellets were prepared in the silicon shot tower; and solar cells were fabricated using web grown where the pellets were used as a replenishment material. Verification runs were made using the boron dopant and liquid diffusion mask materials. The average of cells produced in these runs was 13%. The relationship of sheet resistivity, temperature, gas flows, and gas composition for the diffusion of the P-8 liquid phosphorus solution was investigated. Solar cells processed from web grown from Si shot material were evaluated, and results qualified the use of the material produced in the shot tower for web furnace feed stock.
Heliostat cost optimization study
NASA Astrophysics Data System (ADS)
von Reeken, Finn; Weinrebe, Gerhard; Keck, Thomas; Balz, Markus
2016-05-01
This paper presents a methodology for a heliostat cost optimization study. First different variants of small, medium sized and large heliostats are designed. Then the respective costs, tracking and optical quality are determined. For the calculation of optical quality a structural model of the heliostat is programmed and analyzed using finite element software. The costs are determined based on inquiries and from experience with similar structures. Eventually the levelised electricity costs for a reference power tower plant are calculated. Before each annual simulation run the heliostat field is optimized. Calculated LCOEs are then used to identify the most suitable option(s). Finally, the conclusions and findings of this extensive cost study are used to define the concept of a new cost-efficient heliostat called `Stellio'.
Woody, Carol Ann; Johnson, D.H.; Shrier, Brianna M.; O'Neal, Jennifer S.; Knutzen, John A.; Augerot, Xanthippe; O'Neal, Thomas A.; Pearsons, Todd N.
2007-01-01
Counting towers provide an accurate, low-cost, low-maintenance, low-technology, and easily mobilized escapement estimation program compared to other methods (e.g., weirs, hydroacoustics, mark-recapture, and aerial surveys) (Thompson 1962; Siebel 1967; Cousens et al. 1982; Symons and Waldichuk 1984; Anderson 2000; Alaska Department of Fish and Game 2003). Counting tower data has been found to be consistent with that of digital video counts (Edwards 2005). Counting towers do not interfere with natural fish migration patterns, nor are fish handled or stressed; however, their use is generally limited to clear rivers that meet specific site selection criteria. The data provided by counting tower sampling allow fishery managers to determine reproductive population size, estimate total return (escapement + catch) and its uncertainty, evaluate population productivity and trends, set harvest rates, determine spawning escapement goals, and forecast future returns (Alaska Department of Fish and Game 1974-2000 and 1975-2004). The number of spawning fish is determined by subtracting subsistence, sport-caught fish, and prespawn mortality from the total estimated escapement. The methods outlined in this protocol for tower counts can be used to provide reasonable estimates ( plus or minus 6%-10%) of reproductive salmon population size and run timing in clear rivers.
Investigation of a long time series of CO2 from a tall tower using WRF-SPA
NASA Astrophysics Data System (ADS)
Smallman, Luke; Williams, Mathew; Moncrieff, John B.
2013-04-01
Atmospheric observations from tall towers are an important source of information about CO2 exchange at the regional scale. Here, we have used a forward running model, WRF-SPA, to generate a time series of CO2 at a tall tower for comparison with observations from Scotland over multiple years (2006-2008). We use this comparison to infer strength and distribution of sources and sinks of carbon and ecosystem process information at the seasonal scale. The specific aim of this research is to combine a high resolution (6 km) forward running meteorological model (WRF) with a modified version of a mechanistic ecosystem model (SPA). SPA provides surface fluxes calculated from coupled energy, hydrological and carbon cycles. This closely coupled representation of the biosphere provides realistic surface exchanges to drive mixing within the planetary boundary layer. The combined model is used to investigate the sources and sinks of CO2 and to explore which land surfaces contribute to a time series of hourly observations of atmospheric CO2 at a tall tower, Angus, Scotland. In addition to comparing the modelled CO2 time series to observations, modelled ecosystem specific (i.e. forest, cropland, grassland) CO2 tracers (e.g., assimilation and respiration) have been compared to the modelled land surface assimilation to investigate how representative tall tower observations are of land surface processes. WRF-SPA modelled CO2 time series compares well to observations (R2 = 0.67, rmse = 3.4 ppm, bias = 0.58 ppm). Through comparison of model-observation residuals, we have found evidence that non-cropped components of agricultural land (e.g., hedgerows and forest patches) likely contribute a significant and observable impact on regional carbon balance.
7. BLOCK HOUSE BASEMENT LOOKING THROUGH DOOR INTO CABLE TUNNEL ...
7. BLOCK HOUSE BASEMENT LOOKING THROUGH DOOR INTO CABLE TUNNEL RUNNING BETWEEN BLOCK HOUSE AND STATIC TEST TOWER. - Marshall Space Flight Center, East Test Area, Block House, Huntsville, Madison County, AL
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-15
..., whether or not tapered, and sections thereof. Certain wind towers are designed to support the nacelle and rotor blades in a wind turbine with a minimum rated electrical power generation capacity in excess of... part of a wind turbine (i.e., accompanying nacelles and/or rotor blades). Amendment to the Final...
Doppler lidar signal and turbulence study
NASA Technical Reports Server (NTRS)
Frost, W.; Huang, K. H.; Fitzjarrald, D. F.
1983-01-01
Comparison of the second moments of the Doppler lidar signal with aircraft and tower measured parameters is being carried out. Lidar binary data tapes were successfully converted to ASCII Code on the VAX 11/780. These data were used to develop the computer programs for analyzing data from the Marshall Space Flight Center field test. Raw lidar amplitude along the first 50 forward and backward beams of Run No. 2, respectively was plotted. Plotting techniques for the same beams except with the amplitude thresholded and range corrected were developed. Plotting routines for the corresponding lidar width of the first 50 forward and backward beams were also established. The relationship between raw lidar amplitude and lidar width was examined. The lidar width is roughly constant for lidar amplitudes less than 120 dB. A field test with the NASA/MSFC ground based Doppler lidar, the instrumented NASA B-57B gust gradient aircraft, and the NASA/MSFC eight tower array was carried out. The data tape for the lidar was received and read. The aircraft data and tower data are being digitized and converted to engineering units. Velocities computed sequentially along each of the lidar beams beginning at 16:40:00, May 12, 1983 were plotted for Run No. 1.
75 FR 47591 - Environmental Impacts Statements; Notice Of Availability
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-06
... Thomas 559-784-1500 ext. 1164. EIS No. 20100292, Final EIS, BLM, CA, Ivanpah Solar Electric Generating System (07-AFC-5) Project, Proposal to Construct a 400-m Megawatt Concentrated Solar Power Tower, Thermal... Generation Station (GGS) Project, Proposes to Modify its Interconnection Agreement, Basin Electric Power...
Evaluation of the Luling bridge retrofit details under service loads : final report.
DOT National Transportation Integrated Search
1991-08-01
Extensive strain measurements were carried out on three cross girder boxes used to connect the cable stays to the orthotropic deck-trapezoidal box steel structure. The measurements were obtained at CG3, CG4 and CG5 adjacent to the tower at pier 2. : ...
Direct liquefaction Proof-of-Concept facility. Final technical progress report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Comolli, A.G.; Lee, L.K.; Pradhan, V.R.
1995-08-01
This report presents the results of work which included extensive modifications to HRI`s existing 3 ton per day Process Development Unit (PDU) and completion of the first PDU run. The 58-day Run 1 demonstrated scale-up of the Catalytic Two-Stage Liquefaction (CTSL Process) on Illinois No. 6 coal to produce distillate liquid products at a rate of up to 5 barrels per to of moisture-ash-free coal. The Kerr McGee Rose-SR unit from Wilsonville was redesigned and installed next to the US Filter installation to allow a comparison of the two solids removal systems. Also included was a new enclosed reactor tower,more » upgraded computer controls and a data acquisition system, an alternate power supply, a newly refurbished reactor, an in-line hydrotreater, interstage sampling system, coal handling unit, a new ebullating pump, load cells and improved controls and remodeled preheaters. Distillate liquid yields of 5 barrels/ton of moisture ash free coal were achieved. Coal slurry recycle rates were reduced from the 2--2.5 to 1 ratio demonstrated at Wilsonville to as low as 0.9 to 1. Coal feed rates were increased during the test by 50% while maintaining process performance at a marginally higher reactor severity. Sulfur in the coal was reduced from 4 wt% to ca. 0.02 wt% sulfur in the clean distillate fuel product. More than 3,500 gallons of distillate fuels were collected for evaluation and upgrading studies. The ROSE-SR Process was operated for the first time with a pentane solvent in a steady-state model. The energy rejection of the ash concentrate was consistently below prior data, being as low as 12%, allowing improved liquid yields and recovery.« less
Dynamic analysis of the BMW tower in Munich
NASA Astrophysics Data System (ADS)
Indacochea-Beltran, Joaquin; Elgindy, Pearl; Lee, Elaine; Vignesh, Thiviya; Ansourian, Peter; Tahmasebinia, Faham; Marroquín, Fernando Alonso
2016-08-01
In the 1970s, world famous Austrian architect Karl Schwanzer designed an avant-garde suspended skyscraper for the new BMW headquarters. The BMW Tower was envisioned to resemble a four-cylinder motor and become a symbol for the recent flourishing success of BMW. Throughout its four decades, the BMW Tower has become the main architectural feature of modern Munich and a pride for one of the World leading car manufacturers. The structural design of the BMW Tower represented a major challenge to Germany's finest engineers because the suspended 99.5m-high structure had to whitstand not only static loading but large wind dynamic loading while having deflections within appropriate serviceability limits. Strand7 has been used to determine the stresses and deflections the structure is subjected to in order to analyse its behavior under static and dynamic loadings. Ultimately, this analysis helps to understand the nature of suspended structures in relation to the Eurocode building standards. Finally, thermal resistance has also been analysed using Strand7 to simulate a fire scenario and analyse the behaviour of the cable structure, which is the most critical building component.
Research on Condition Assessment Method of Transmission Tower Under the Action of Strong Wind
NASA Astrophysics Data System (ADS)
Huang, Ren-mou; An, Li-qiang; Zhang, Rong-lun; Wu, Jiong; Liang, Ya-feng
2018-03-01
Transmission towers are often subjected to the external damage of severe weather like strong wind and so on, which may cause the collapse due to the yield and fracture of the tower material. Aiming this issue, an assessment method was proposed in this paper to assess the operation condition of transmission towers under strong wind. With a reasonable assess index system established firstly, then the internal force of the tower material was solved and its stability was determined through the mechanical analysis of the transmission tower finite element model. Meanwhile, the condition risk level of the tower was finally determined by considering the difference among the influences of other factors like corrosion and loose of members, slope on the transmission tower through the analytic hierarchy process. The assessment method was applied to assess the wind-induced collapse of towers in 110kV Bao Yi II line in Wenchang City, Hainan Province, of which the result proves the method can assess the condition of transmission tower under strong wind and of guiding significance for improving the windproof capability of transmission towers.
5. View of south tower, facing northnortheast from south bank ...
5. View of south tower, facing north-northeast from south bank of the Columbia River. Center tower and north tower in background, lower right. - Pasco-Kennewick Transmission Line, Columbia River Crossing Towers, Columbia Drive & Gum Street, Kennewick, Benton County, WA
5. VIEW EAST, height finder radar towers, radar tower (unknown ...
5. VIEW EAST, height finder radar towers, radar tower (unknown function), prime search radar tower, operations building, and central heating plant - Fort Custer Military Reservation, P-67 Radar Station, .25 mile north of Dickman Road, east of Clark Road, Battle Creek, Calhoun County, MI
Seismic response of a full-scale wind turbine tower using experimental and numerical modal analysis
NASA Astrophysics Data System (ADS)
Kandil, Kamel Sayed Ahmad; Saudi, Ghada N.; Eltaly, Boshra Aboul-Anen; El-khier, Mostafa Mahmoud Abo
2016-12-01
Wind turbine technology has developed tremendously over the past years. In Egypt, the Zafarana wind farm is currently generating at a capacity of 517 MW, making it one of the largest onshore wind farms in the world. It is located in an active seismic zone along the west side of the Gulf of Suez. Accordingly, seismic risk assessment is demanded for studying the structural integrity of wind towers under expected seismic hazard events. In the context of ongoing joint Egypt-US research project "Seismic Risk Assessment of Wind Turbine Towers in Zafarana wind Farm Egypt" (Project ID: 4588), this paper describes the dynamic performance investigation of an existing Nordex N43 wind turbine tower. Both experimental and numerical work are illustrated explaining the methodology adopted to investigate the dynamic behavior of the tower under seismic load. Field dynamic testing of the full-scale tower was performed using ambient vibration techniques (AVT). Both frequency domain and time domain methods were utilized to identify the actual dynamic properties of the tower as built in the site. Mainly, the natural frequencies, their corresponding mode shapes and damping ratios of the tower were successfully identified using AVT. A vibration-based finite element model (FEM) was constructed using ANSYS V.12 software. The numerical and experimental results of modal analysis were both compared for matching purpose. Using different simulation considerations, the initial FEM was updated to finally match the experimental results with good agreement. Using the final updated FEM, the response of the tower under the AQABA earthquake excitation was investigated. Time history analysis was conducted to define the seismic response of the tower in terms of the structural stresses and displacements. This work is considered as one of the pioneer structural studies of the wind turbine towers in Egypt. Identification of the actual dynamic properties of the existing tower was successfully performed based on AVT. Using advanced techniques in both the field testing and the numerical investigations produced reliable FEM specific for the tested tower, which can be further used in more advanced structural investigations for improving the design of such special structures.
Design and Manufacturing of Composite Tower Structure for Wind Turbine Equipment
NASA Astrophysics Data System (ADS)
Park, Hyunbum
2018-02-01
This study proposes the composite tower design process for large wind turbine equipment. In this work, structural design of tower and analysis using finite element method was performed. After structural design, prototype blade manufacturing and test was performed. The used material is a glass fiber and epoxy resin composite. And also, sand was used in the middle part. The optimized structural design and analysis was performed. The parameter for optimized structural design is weight reduction and safety of structure. Finally, structure of tower will be confirmed by structural test.
Fire ants perpetually rebuild sinking towers.
Phonekeo, Sulisay; Mlot, Nathan; Monaenkova, Daria; Hu, David L; Tovey, Craig
2017-07-01
In the aftermath of a flood, fire ants, Solenopsis invicta , cluster into temporary encampments. The encampments can contain hundreds of thousands of ants and reach over 30 ants high. How do ants build such tall structures without being crushed? In this combined experimental and theoretical study, we investigate the shape and rate of construction of ant towers around a central support. The towers are bell shaped, consistent with towers of constant strength such as the Eiffel tower, where each element bears an equal load. However, unlike the Eiffel tower, the ant tower is built through a process of trial and error, whereby failed portions avalanche until the final shape emerges. High-speed and novel X-ray videography reveal that the tower constantly sinks and is rebuilt, reminiscent of large multicellular systems such as human skin. We combine the behavioural rules that produce rafts on water with measurements of adhesion and attachment strength to model the rate of growth of the tower. The model correctly predicts that the growth rate decreases as the support diameter increases. This work may inspire the design of synthetic swarms capable of building in vertical layers.
Fire ants perpetually rebuild sinking towers
NASA Astrophysics Data System (ADS)
Phonekeo, Sulisay; Mlot, Nathan; Monaenkova, Daria; Hu, David L.; Tovey, Craig
2017-07-01
In the aftermath of a flood, fire ants, Solenopsis invicta, cluster into temporary encampments. The encampments can contain hundreds of thousands of ants and reach over 30 ants high. How do ants build such tall structures without being crushed? In this combined experimental and theoretical study, we investigate the shape and rate of construction of ant towers around a central support. The towers are bell shaped, consistent with towers of constant strength such as the Eiffel tower, where each element bears an equal load. However, unlike the Eiffel tower, the ant tower is built through a process of trial and error, whereby failed portions avalanche until the final shape emerges. High-speed and novel X-ray videography reveal that the tower constantly sinks and is rebuilt, reminiscent of large multicellular systems such as human skin. We combine the behavioural rules that produce rafts on water with measurements of adhesion and attachment strength to model the rate of growth of the tower. The model correctly predicts that the growth rate decreases as the support diameter increases. This work may inspire the design of synthetic swarms capable of building in vertical layers.
Fire ants perpetually rebuild sinking towers
Phonekeo, Sulisay; Mlot, Nathan; Monaenkova, Daria; Tovey, Craig
2017-01-01
In the aftermath of a flood, fire ants, Solenopsis invicta, cluster into temporary encampments. The encampments can contain hundreds of thousands of ants and reach over 30 ants high. How do ants build such tall structures without being crushed? In this combined experimental and theoretical study, we investigate the shape and rate of construction of ant towers around a central support. The towers are bell shaped, consistent with towers of constant strength such as the Eiffel tower, where each element bears an equal load. However, unlike the Eiffel tower, the ant tower is built through a process of trial and error, whereby failed portions avalanche until the final shape emerges. High-speed and novel X-ray videography reveal that the tower constantly sinks and is rebuilt, reminiscent of large multicellular systems such as human skin. We combine the behavioural rules that produce rafts on water with measurements of adhesion and attachment strength to model the rate of growth of the tower. The model correctly predicts that the growth rate decreases as the support diameter increases. This work may inspire the design of synthetic swarms capable of building in vertical layers. PMID:28791170
View from intersection. Ninestory reinforced concrete building infilled with brick. ...
View from intersection. Nine-story reinforced concrete building infilled with brick. The street facades on beaubien and east grand are faced with stone accents and elaborate brick work. Brick pilasters run the entire height of the building. Steel tiebacks are apparent running up the height of the building on the east side. The large tower appears at the northeast and southeast corners - Detroit Storage Company, 2937 East Grand Boulevard, Detroit, MI
Flux Sampling Errors for Aircraft and Towers
NASA Technical Reports Server (NTRS)
Mahrt, Larry
1998-01-01
Various errors and influences leading to differences between tower- and aircraft-measured fluxes are surveyed. This survey is motivated by reports in the literature that aircraft fluxes are sometimes smaller than tower-measured fluxes. Both tower and aircraft flux errors are larger with surface heterogeneity due to several independent effects. Surface heterogeneity may cause tower flux errors to increase with decreasing wind speed. Techniques to assess flux sampling error are reviewed. Such error estimates suffer various degrees of inapplicability in real geophysical time series due to nonstationarity of tower time series (or inhomogeneity of aircraft data). A new measure for nonstationarity is developed that eliminates assumptions on the form of the nonstationarity inherent in previous methods. When this nonstationarity measure becomes large, the surface energy imbalance increases sharply. Finally, strategies for obtaining adequate flux sampling using repeated aircraft passes and grid patterns are outlined.
Validating GPM-based Multi-satellite IMERG Products Over South Korea
NASA Astrophysics Data System (ADS)
Wang, J.; Petersen, W. A.; Wolff, D. B.; Ryu, G. H.
2017-12-01
Accurate precipitation estimates derived from space-borne satellite measurements are critical for a wide variety of applications such as water budget studies, and prevention or mitigation of natural hazards caused by extreme precipitation events. This study validates the near-real-time Early Run, Late Run and the research-quality Final Run Integrated Multi-Satellite Retrievals for GPM (IMERG) using Korean Quantitative Precipitation Estimation (QPE). The Korean QPE data are at a 1-hour temporal resolution and 1-km by 1-km spatial resolution, and were developed by Korea Meteorological Administration (KMA) from a Real-time ADjusted Radar-AWS (Automatic Weather Station) Rainrate (RAD-RAR) system utilizing eleven radars over the Republic of Korea. The validation is conducted by comparing Version-04A IMERG (Early, Late and Final Runs) with Korean QPE over the area (124.5E-130.5E, 32.5N-39N) at various spatial and temporal scales during March 2014 through November 2016. The comparisons demonstrate the reasonably good ability of Version-04A IMERG products in estimating precipitation over South Korea's complex topography that consists mainly of hills and mountains, as well as large coastal plains. Based on this data, the Early Run, Late Run and Final Run IMERG precipitation estimates higher than 0.1mm h-1 are about 20.1%, 7.5% and 6.1% higher than Korean QPE at 0.1o and 1-hour resolutions. Detailed comparison results are available at https://wallops-prf.gsfc.nasa.gov/KoreanQPE.V04/index.html
DIME Students Discuss Final Drop Tower Experiment Design
NASA Technical Reports Server (NTRS)
2002-01-01
Students discuss fine points of their final design for the Drop Tower experiment during the second Dropping in a Microgravity Environment (DIME) competition held April 23-25, 2002, at NASA's Glenn Research Center. Competitors included two teams from Sycamore High School, Cincinnati, OH, and one each from Bay High School, Bay Village, OH, and COSI Academy, Columbus, OH. DIME is part of NASA's education and outreach activities. Details are on line at http://microgravity.grc.nasa.gov/DIME_2002.html.
47 CFR 5.109 - Antenna and tower requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 1 2011-10-01 2011-10-01 false Antenna and tower requirements. 5.109 Section 5... BROADCAST) Technical Standards and Operating Requirements § 5.109 Antenna and tower requirements. (a) Applicants with fixed stations that use antennas that exceed 6 meters in height above the ground level or...
47 CFR 5.109 - Antenna and tower requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Antenna and tower requirements. 5.109 Section 5... BROADCAST) Technical Standards and Operating Requirements § 5.109 Antenna and tower requirements. (a) Applicants with fixed stations that use antennas that exceed 6 meters in height above the ground level or...
47 CFR 5.109 - Antenna and tower requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 1 2012-10-01 2012-10-01 false Antenna and tower requirements. 5.109 Section 5... BROADCAST) Technical Standards and Operating Requirements § 5.109 Antenna and tower requirements. (a) Applicants with fixed stations that use antennas that exceed 6 meters in height above the ground level or...
Observation Denial and Performance of a Local Mesoscale Model
NASA Technical Reports Server (NTRS)
Watson, Leela R.; Bauman, William H., III
2009-01-01
.Forecasters at the 45th Weather Squadron (45 WS) use observations from the Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS) wind tower network and the CCAFS (XMR) daily rawinsonde observations (RAOB) to issue and verify wind advisories and warnings for operations. These observations are also used by the National Weather Service (NWS) Spaceflight Meteorology Group (SMG) in Houston, Texas and the NWS Melbourne, Florida (NWS MLB) to initialize their locally-run mesoscale models. In addition, SMG uses these observations to support shuttle landings at the Shuttle Landing Facility (SLF). Due to impending budget cuts, some or all of the wind towers on the east-central Florida mainland and the XMR RAOBs may be eliminated. The locations of the mainland towers and XMR RAOB site are shown in Figure 1. The loss of these data may impact the forecast capability of the 45 WS, SMG and NWS MLB.
36. BOILER HOUSE, GENERAL VIEW LOOKING TOWARD COAL CAR No. ...
36. BOILER HOUSE, GENERAL VIEW LOOKING TOWARD COAL CAR No. 6 (NOTE: COAL DISTRIBUTER HOPPER & CONVEYOR THAT RUNS NORTH TO SOUTH BETWEEN TRACKS ON EAST TOWER SIDE) - Delaware County Electric Company, Chester Station, Delaware River at South end of Ward Street, Chester, Delaware County, PA
NASA Astrophysics Data System (ADS)
Schmidt, A.; Rella, C.; Conley, S. A.; Goeckede, M.; Law, B. E.
2013-12-01
The NOAA CO2 observation network in Oregon has been enhanced by 3 new towers in 2012. The tallest tower in the network (270 m), located in Silverton in the Willamette Valley is affected by anthropogenic emissions from Oregon's busiest traffic routes and urban centers. In summer 2012, we conducted a measurement campaign using a car-mounted PICARRO CRDS CO2/CO analyzer. Over 3 days, the instrument was driven over 1000 miles throughout the northwestern portion of Oregon measuring the CO/ CO2 ratios on main highways, back roads in forests, agricultural sites, and Oregon's biggest urban centers. By geospatial analyses we obtained ratios of CO/ CO2 over distinct land cover types divided into 10 classes represented in the study area. Using the coupled WRF-STILT transport model we calculated the footprints of nearby CO/ CO2 observation towers for the corresponding days of mobile road measurements. Spatiotemporally assigned source areas in combination with the land use classification were then used to calculate specific ratios of CO (anthropogenic origins) and CO2 to separate the anthropogenic portion of CO2 from the mixing ratio time series measured at the tower in Silverton. The WRF modeled boundary layer heights used in out study showed some differences compared to the boundary layer heights derived from profile data of wind, temperature, and humidity measured with an airplane in August, September, and November 2012, repeatedly over 5 tower locations. A Bayesian Regularized Artificial Neural Network (BRANN) was used to correct the boundary layer height calculated with WRF with a temporal resolution of 20 minutes and a horizontal resolution of 4 km. For that purpose the BRANN was trained using height profile data from the flight campaigns and spatiotemporally corresponding meteorological data from WRF. Our analyses provide information needed to run inverse modeling of CO2 exchange in an area that is affected by sources that cannot easily be considered by biospheric models. The results help to account for regional anthropogenic influences using long-term tower data and supporting short-term campaigns. Figure 1: The footprint areas of 2 NOAA observation towers (72 m inlet at Walton and 212 m inlet at Silverton) during the 3-day campaign with the car-mounted PICARRO CRDS on July 10 (a), July 11 (b), and July 12 (c) 2012 together with the main roads and urban centers. The orange lines show the routes driven during those days.
NASA Astrophysics Data System (ADS)
Burba, George; Avenson, Tom; Burkart, Andreas; Gamon, John; Guan, Kaiyu; Julitta, Tommaso; Pastorello, Gilberto; Sakowska, Karolina
2017-04-01
Multiple hundreds of flux towers are presently operational as standalone projects and as parts of larger networks. However, the vast majority of these towers do not allow straight-forward coupling with satellite data, and even fewer have optical sensors for validation of satellite products and upscaling from field to regional levels. In 2016, new tools to collect, process, and share time-synchronized flux data from multiple towers were developed and deployed globally. Originally designed to automate site and data management, these new tools can also be effective in coupling tower data with satellite data due to the following present capabilities: Fully automated FluxSuite system combines hardware, software and web-services, and does not require an expert to run it It can be incorporated into a new flux station or added to a present station, using weatherized remotely-accessible microcomputer, SmartFlux2 It utilizes EddyPro software to calculate fully-processed fluxes and footprints in near-realtime, alongside radiation, optical, weather and soil data All site data are merged into a single quality-controlled file timed using PTP time protocol Data from optical sensors can be integrated into this complete dataset via compatible dataloggers Multiple stations can be linked into time-synchronized network with automated reports and email alerts visible to PIs in real-time Remote sensing researchers without stations can form "virtual networks" of stations by collaborating with tower PIs from different physical networks The present system can then be utilized to couple ground data with satellite data via the following proposed concept: GPS-driven PTP protocol will synchronize instrumentation within the station, different stations with each other, and all of these to satellite data to precisely align optical and flux data in time Footprint size and coordinates computed and stored with flux data will help correctly align footprints and satellite motion to precisely align optical and flux data in space Current flux towers can be augmented with ground optical sensors and use standard routines to deliver continuous products (e.g. SIF, PRI, NDVI, etc.) based on automated field spectrometers (e.g., FloX and RoX, etc.) and other optical systems Schedule can be developed to point ground optical sensor into the footprint, or to run leaf chamber measurements in the footprint, at the same time with the satellite or UAV above the footprint Full snapshot of the satellite pixel can then be constructed including leaf-level, ground optical sensor, and flux measurements from the same footprint area closely coupled with the satellite measurements to help interpret satellite data, validate models, and improve upscaling Several dozens of new towers already operational globally can be readily adapted for the proposed concept. In addition, over 500 active traditional towers can be updated to synchronize their data with satellite measurements. This presentation will show how FluxSuite system is used by major networks, and describe the concept of how this approach can be utilized to couple satellite and tower data.
BOREAS RSS-8 BIOME-BGC Model Simulations at Tower Flux Sites in 1994
NASA Technical Reports Server (NTRS)
Hall, Forrest G. (Editor); Nickeson, Jaime (Editor); Kimball, John
2000-01-01
BIOME-BGC is a general ecosystem process model designed to simulate biogeochemical and hydrologic processes across multiple scales (Running and Hunt, 1993). In this investigation, BIOME-BGC was used to estimate daily water and carbon budgets for the BOREAS tower flux sites for 1994. Carbon variables estimated by the model include gross primary production (i.e., net photosynthesis), maintenance and heterotrophic respiration, net primary production, and net ecosystem carbon exchange. Hydrologic variables estimated by the model include snowcover, evaporation, transpiration, evapotranspiration, soil moisture, and outflow. The information provided by the investigation includes input initialization and model output files for various sites in tabular ASCII format.
LCOE reduction potential of parabolic trough and solar tower CSP technology until 2025
NASA Astrophysics Data System (ADS)
Dieckmann, Simon; Dersch, Jürgen; Giuliano, Stefano; Puppe, Michael; Lüpfert, Eckhard; Hennecke, Klaus; Pitz-Paal, Robert; Taylor, Michael; Ralon, Pablo
2017-06-01
Concentrating Solar Power (CSP), with an installed capacity of 4.9 GW by 2015, is a young technology compared to other renewable power generation technologies. A limited number of plants and installed capacity in a small challenging market environment make reliable and transparent cost data for CSP difficult to obtain. The International Renewable Energy Agency (IRENA) and the DLR German Aerospace Center gathered and evaluated available cost data from various sources for this publication in order to yield transparent, reliable and up-to-date cost data for a set of reference parabolic trough and solar tower plants in the year 2015 [1]. Each component of the power plant is analyzed for future technical innovations and cost reduction potential based on current R&D activities, ongoing commercial developments and growth in market scale. The derived levelized cost of electricity (LCOE) for 2015 and 2025 are finally contrasted with published power purchase agreements (PPA) of the NOOR II+III power plants in Morocco. At 7.5% weighted average cost of capital (WACC) and 25 years economic life time, the levelized costs of electricity for plants with 7.5 (trough) respectively 9 (tower) full-load hours thermal storage capacity decrease from 14-15 -ct/kWh today to 9-10 -ct/kWh by 2025 for both technologies at direct normal irradiation of 2500 kWh/(m².a). The capacity factor increases from 41.1% to 44.6% for troughs and from 45.5% to 49.0% for towers. Financing conditions are a major cost driver and offer potential for further cost reduction with the maturity of the technology and low interest rates (6-7 - ct/kWh for 2% WACC at 2500 kWh/(m2.a) in 2025).
78 FR 23489 - Drawbridge Operation Regulation; Sacramento River, Sacramento, CA
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-19
... Operation Regulation; Sacramento River, Sacramento, CA AGENCY: Coast Guard, DHS. ACTION: Notice of deviation... operating regulation that governs the Tower Drawbridge across Sacramento River, mile 59.0, at Sacramento, CA. The deviation is necessary to allow the community to participate in the Capital City Classic Run. This...
Cooling towers, the neglected energy conservations and money making machine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burger, R.
1996-12-31
The heat Rejection Industry defines a nominal cooling tower as circulating three gallons of water per minute (GPM) per ton of refrigeration from entering the tower at 95 {degrees}F, Hot Water temperature (HWT), Leaving at 85{degrees}F Cold Water Temperature (CWT) at a Design Wet Bulb of 70{degrees}F (WBT). Manufacturers then provide a selection chart based on various wet bulb temperatures and HWTs. The wet bulb fluctuates and varies throughout the world since it is the combination ambient temperature, relative humidity, and/or dew point. Different HWT and CWT requirements are usually charted as they change, so that the user can selectmore » the nominal cooling tower model recommended by the manufacturer. In the specification of cooling towers it is necessary to clearly understand the definition of nominal cooling tower, and to make sure the specification you need addressed can be met by the system you purchase. This should be tested prior to final acceptance.« less
On the use of tower-flux measurements to assess the performance of global ecosystem models
NASA Astrophysics Data System (ADS)
El Maayar, M.; Kucharik, C.
2003-04-01
Global ecosystem models are important tools for the study of biospheric processes and their responses to environmental changes. Such models typically translate knowledge, gained from local observations, into estimates of regional or even global outcomes of ecosystem processes. A typical test of ecosystem models consists of comparing their output against tower-flux measurements of land surface-atmosphere exchange of heat and mass. To perform such tests, models are typically run using detailed information on soil properties (texture, carbon content,...) and vegetation structure observed at the experimental site (e.g., vegetation height, vegetation phenology, leaf photosynthetic characteristics,...). In global simulations, however, earth's vegetation is typically represented by a limited number of plant functional types (PFT; group of plant species that have similar physiological and ecological characteristics). For each PFT (e.g., temperate broadleaf trees, boreal conifer evergreen trees,...), which can cover a very large area, a set of typical physiological and physical parameters are assigned. Thus, a legitimate question arises: How does the performance of a global ecosystem model run using detailed site-specific parameters compare with the performance of a less detailed global version where generic parameters are attributed to a group of vegetation species forming a PFT? To answer this question, we used a multiyear dataset, measured at two forest sites with contrasting environments, to compare seasonal and interannual variability of surface-atmosphere exchange of water and carbon predicted by the Integrated BIosphere Simulator-Dynamic Global Vegetation Model. Two types of simulations were, thus, performed: a) Detailed runs: observed vegetation characteristics (leaf area index, vegetation height,...) and soil carbon content, in addition to climate and soil type, are specified for model run; and b) Generic runs: when only observed climates and soil types at the measurement sites are used to run the model. The generic runs were performed for the number of years equal to the current age of the forests, initialized with no vegetation and a soil carbon density equal to zero.
The Year of Transition in Review
2007-01-01
quarter that 114 border forts have been constructed thus far, and 5 points of entry have been completed.315 SIGIR’s ground project surveys ...security services.366 Lt. Gen. Dempsey recently estimated that 20-25% of the National Police “needed to be weeded out.”367 Finally, recent surveys ...sector development Transportation and Communications system, 33 site surveys have been completed for the communication towers between Mosul and
1976-05-01
film airflow anemometry used for vortex measurements in the series of tests is described in reference 6. However, there were two major differences in...LOCKHEED 11011 TRAILING VORTEX SYSTEM USING TOWER FLY-BY TECHNIQUE Leo J. fiarodz ,OtTt4V MAY 1976 FINAL REPORT D k ■?tp r~ "ft UElaibu u...THE LOCKHEED L1011 TRAILING VORTEX SYSTEM USING TOWER FLY-BY TECHNIQUE 7. Authc Leo J. Garodz 9. Performing Orgoni lotion Nome ond Address
2003-12-17
KENNEDY SPACE CENTER, FLA. -- A new control tower is nearing completion at the KSC Shuttle Landing Facility. It will replace the old tower in use since 1987. The old tower stands only 20 feet above the runway surface, too low to see the launch pads to the east. During nighttime landing operations, those inside the tower have been hindered by the eight-billion candlepower xenon lights that illuminate the runway. The new control tower is built atop an existing mound, rising nearly 100 feet over the midpoint of the runway. The height gives controllers a spectacular 360-degree view of NASA-KSC and northern Brevard County. The new facility will also replace the SLF Operations Building. The operations building is home to the Military Radar Unit that monitors NASA-KSC airspace 24 hours a day, as well as runway light controls, navigational aids, weather and wind speed instrumentation, and gate controls. In the new tower, the computer displays will be fully modernized to Federal Aviation Administration standards with touch-screen technology. Construction on the new facility began in February 2003 and is nearly ready for occupancy. Only some final inspections and approvals remain. A support building and Public Affairs viewing deck, to be used for observing future landing operations, will be added and are already in work.
NASA Astrophysics Data System (ADS)
Simkins, J.; Desai, A. R.; Cowdery, E.; Dietze, M.; Rollinson, C.
2016-12-01
The terrestrial biosphere assimilates nearly one fourth of anthropogenic carbon dioxide emissions, providing a significant ecosystem service. Anthropogenic climate changes that influence the distribution and frequency of weather extremes and can have a momentous impact on this useful function that ecosystems provide. However, most analyses of the impact of extreme events on ecosystem carbon uptake do not integrate across the wide range of structural, parametric, and driver uncertainty that needs to be taken into account to estimate probability of changes to ecosystem function under shifts in climate patterns. In order to improve ecosystem model forecasts, we integrated and estimated these sources of uncertainty using an open-sourced informatics workflow, the Predictive ECosystem Analyzer (PEcAn, http://pecanproject.org). PEcAn allows any researcher to parameterize and run multiple ecosystem models and automate extraction of meteorological forcing and estimation of its uncertainty. Trait databases and a uniform protocol for parameterizing and driving models were used to test parametric and structural uncertainty. In order to sample the uncertainty in future projected meteorological drivers, we developed automated extraction routines to acquire site-level three-hourly Coupled Model Intercomparison Project 5 (CMIP5) forcing data from the Geophysical Fluid Dynamics Laboratory general circulation models (CM3, ESM2M, and ESM2G) across the r1i1p1, r3i1p1 and r5i1p1 ensembles and AR5 emission scenarios. We also implemented a site-level high temporal resolution downscaling technique for these forcings calibrated against half-hourly eddy covariance flux tower observations. Our hypothesis claims that parametric and driver uncertainty dominate over the model structural uncertainty. In order to test this, we partition the uncertainty budget on the ChEAS regional network of towers in Northern Wisconsin, USA where each tower is located in forest and wetland ecosystems.
BOREAS TF-5 SSA-OJP Tower Flux and Meteorological Data
NASA Technical Reports Server (NTRS)
Baldocchi, Dennis; Vogel, Christoph; Hall, Forrest G. (Editor); Huemmrich, Karl (Editor)
2000-01-01
The BOReal Ecosystem-Atmosphere Study Tower Flux (BOREAS TF-5) team collected tower flux data at the BOREAS Southern Study Area Old Jack Pine (SSA-OJP) site through the growing season of 1994. The data are available in tabular ASCII files.
Molten Salt Power Tower Cost Model for the System Advisor Model (SAM)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Turchi, C. S.; Heath, G. A.
2013-02-01
This report describes a component-based cost model developed for molten-salt power tower solar power plants. The cost model was developed by the National Renewable Energy Laboratory (NREL), using data from several prior studies, including a contracted analysis from WorleyParsons Group, which is included herein as an Appendix. The WorleyParsons' analysis also estimated material composition and mass for the plant to facilitate a life cycle analysis of the molten salt power tower technology. Details of the life cycle assessment have been published elsewhere. The cost model provides a reference plant that interfaces with NREL's System Advisor Model or SAM. The referencemore » plant assumes a nominal 100-MWe (net) power tower running with a nitrate salt heat transfer fluid (HTF). Thermal energy storage is provided by direct storage of the HTF in a two-tank system. The design assumes dry-cooling. The model includes a spreadsheet that interfaces with SAM via the Excel Exchange option in SAM. The spreadsheet allows users to estimate the costs of different-size plants and to take into account changes in commodity prices. This report and the accompanying Excel spreadsheet can be downloaded at https://sam.nrel.gov/cost.« less
Electronics for a highly segmented electromagnetic calorimeter prototype
NASA Astrophysics Data System (ADS)
Fehlker, D.; Alme, J.; van den Brink, A.; de Haas, A. P.; Nooren, G.-J.; Reicher, M.; Röhrich, D.; Rossewij, M.; Ullaland, K.; Yang, S.
2013-03-01
A prototype of a highly segmented electromagnetic calorimeter has been developed. The detector tower is made of 24 layers of PHASE2/MIMOSA23 silicon sensors sandwiched between tungsten plates, with 4 sensors per layer, a total of 96 MIMOSA sensors, resulting in 39 MPixels for the complete prototype detector tower. The paper focuses on the electronics of this calorimeter prototype. Two detector readout and control systems are used, each containing two Spartan 6 and one Virtex 6 FPGA, running embedded Linux, each system serving 12 detector layers. In 550 ms a total of 4 Gbytes of data is read from the detector, stored in memory on the electronics and then shipped to the DAQ system via Gigabit ethernet.
NASA Technical Reports Server (NTRS)
Frederick, G. R.; Winemiller, J. R.; Savino, J. M.
1982-01-01
Three designs of a guyed cylindrical tower and its foundation for an intermediate size horizontal axis wind turbine generator are discussed. The primary difference in the three designs is the configuration of the rotor. Two configurations are two-blade rotors with teetering hubs - one with full span pitchable blades, the other with fixed pitch blades. The third configuration is a three-bladed rotor with a rigid hub and fixed pitch blades. In all configurations the diameter of the rotor is 38 meters and the axis of rotation is 30.4 meters above grade, and the power output is 200 kW and 400 kW. For each configuration the design is based upon for the most severe loading condition either operating wind or hurricane conditions. The diameter of the tower is selected to be 1.5 meters (since it was determined that this would provide sufficient space for access ladders within the tower) with guy rods attached at 10.7 meters above grade. Completing a design requires selecting the required thicknesses of the various cylindrical segments, the number and diameter of the guy rods, the number and size of soil anchors, and the size of the central foundation. The lower natural frequencies of vibration are determined for each design to ensure that operation near resonance does not occur. Finally, a cost estimate is prepared for each design. A preliminary design and cost estimate of a cantilever tower (cylindrical and not guyed) and its foundation is also presented for each of the three configurations.
Radiation Testing of PICA at the Solar Power Tower
NASA Technical Reports Server (NTRS)
White, Susan M.
2010-01-01
Sandia National Laboratory's Solar Power Tower was used to irradiate specimens of Phenolic Impregnated Carbon Ablator (PICA), in order to evaluate whether this thermal protection system material responded differently to potential shock layer radiative heating than to convective heating. Tests were run at 50, 100 and 150 Watts per square centimeter levels of concentrated solar radiation. Experimental results are presented both from spectral measurements on 1- 10 mm thick specimens of PICA, as well as from in-depth temperature measurements on instrumented thicker test specimens. Both spectral measurements and measured in-depth temperature profiles showed that, although it is a porous, low-density material, PICA does not exhibit problematic transparency to the tested high levels of NIR radiation, for all pragmatic cm-to-inch scale thicknesses. PICA acted as a surface absorber to efficiently absorb the incident visible and near infrared incident radiation in the top 2 millimeter layer in the Solar Power Tower tests up to 150 Watts per square centimeter.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-26
..., whether or not tapered, and sections thereof. Certain wind towers are designed to support the nacelle and rotor blades in a wind turbine with a minimum rated electrical power generation capacity in excess of... joined with nonsubject merchandise, such as nacelles or rotor blades, and whether or not they have...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wendt, Fabian F; Robertson, Amy N; Jonkman, Jason
During the course of the Offshore Code Comparison Collaboration, Continued, with Correlation (OC5) project, which focused on the validation of numerical methods through comparison against tank test data, the authors created a numerical FAST model of the 1:50-scale DeepCwind semisubmersible system that was tested at the Maritime Research Institute Netherlands ocean basin in 2013. This paper discusses several model calibration studies that were conducted to identify model adjustments that improve the agreement between the numerical simulations and the experimental test data. These calibration studies cover wind-field-specific parameters (coherence, turbulence), hydrodynamic and aerodynamic modeling approaches, as well as rotor model (blade-pitchmore » and blade-mass imbalances) and tower model (structural tower damping coefficient) adjustments. These calibration studies were conducted based on relatively simple calibration load cases (wave only/wind only). The agreement between the final FAST model and experimental measurements is then assessed based on more-complex combined wind and wave validation cases.« less
2003-12-17
KENNEDY SPACE CENTER, FLA. -- Two control towers are seen at the edge of the KSC Shuttle Landing Facility, the old one in front and the nearly completed new tower in back. The old tower stands only 20 feet above the runway surface, too low to see the launch pads to the east. During nighttime landing operations, those inside the tower have been hindered by the eight-billion candlepower xenon lights that illuminate the runway. The new control tower is built atop an existing mound, rising nearly 100 feet over the midpoint of the runway. The height gives controllers a spectacular 360-degree view of NASA-KSC and northern Brevard County. The new facility will also replace the SLF Operations Building. The operations building is home to the Military Radar Unit that monitors NASA-KSC airspace 24 hours a day, as well as runway light controls, navigational aids, weather and wind speed instrumentation, and gate controls. In the new tower, the computer displays will be fully modernized to Federal Aviation Administration standards with touch-screen technology. Construction on the new facility began in February 2003 and is nearly ready for occupancy. Only some final inspections and approvals remain. A support building and Public Affairs viewing deck, to be used for observing future landing operations, will be added and are already in work.
1997-12-16
The access tower around the Athena II rocket for the Lunar Prospector spacecraft, to be launched for NASA by Lockheed Martin, was rolled back today at Launch Complex 46 at Cape Canaveral Air Station for final prelaunch preparations. The small robotic spacecraft is designed to provide the first global maps of the Moon's surface compositional elements and its gravitational and magnetic fields. The launch of Lunar Prospector is currently scheduled for Jan. 5, 1998 at 8:31 p.m
1997-12-16
The access tower around the Athena II rocket for the Lunar Prospector spacecraft, to be launched for NASA by Lockheed Martin, was rolled back today at Launch Complex 46 at Cape Canaveral Air Station for final prelaunch preparations. The small robotic spacecraft is designed to provide the first global maps of the Moon's surface compositional elements and its gravitational and magnetic fields. The launch of Lunar Prospector is currently scheduled for Jan. 5, 1998 at 8:31 p.m
Special Inspector General for Iraq Reconstruction, Report to Congress, January 30, 2007
2007-01-30
quarter that 114 border forts have been constructed thus far, and 5 points of entry have been completed.315 SIGIR’s ground project surveys ...security services.366 Lt. Gen. Dempsey recently estimated that 20-25% of the National Police “needed to be weeded out.”367 Finally, recent surveys ...sector development Transportation and Communications system, 33 site surveys have been completed for the communication towers between Mosul and
Wimpy Radar Antenna! Grades 6-8.
ERIC Educational Resources Information Center
Rushton, Erik; Ryan, Emily; Swift, Charles
In this activity, students reinforce an antenna tower made from foam insulation so that it can withstand a 480 N-cm bending moment (torque) and a 280 N-cm twisting moment (torque) with minimal deflection. One class period is used to discuss the problem, run the initial bending and torsion tests, and graph the results. The second class is used for…
The ASE Improving Practical Work in Triple Science Learning Skills Network
ERIC Educational Resources Information Center
Barber, Paul; Chapman, Georgina; Ellis-Sackey, Cecilia; Grainger, Beth; Jones, Steve
2011-01-01
In July 2010, the Association for Science Education won a bid to run a "Sharing innovation network" for the Triple Science Support Programme, which is delivered by the Learning Skills Network on behalf of the Department for Education. The network involves schools from the London boroughs of Tower Hamlets and Greenwich. In this article,…
Droplet combustion experiment drop tower tests using models of the space flight apparatus
NASA Technical Reports Server (NTRS)
Haggard, J. B.; Brace, M. H.; Kropp, J. L.; Dryer, F. L.
1989-01-01
The Droplet Combustion Experiment (DCE) is an experiment that is being developed to ultimately operate in the shuttle environment (middeck or Spacelab). The current experiment implementation is for use in the 2.2 or 5 sec drop towers at NASA Lewis Research Center. Initial results were reported in the 1986 symposium of this meeting. Since then significant progress was made in drop tower instrumentation. The 2.2 sec drop tower apparatus, a conceptual level model, was improved to give more reproducible performance as well as operate over a wider range of test conditions. Some very low velocity deployments of ignited droplets were observed. An engineering model was built at TRW. This model will be used in the 5 sec drop tower operation to obtain science data. In addition, it was built using the flight design except for changes to accommodate the drop tower requirements. The mechanical and electrical assemblies have the same level of complexity as they will have in flight. The model was tested for functional operation and then delivered to NASA Lewis. The model was then integrated into the 5 sec drop tower. The model is currently undergoing initial operational tests prior to starting the science tests.
Development of the New DAQ System for the SD Array of TA×4 and TALE
NASA Astrophysics Data System (ADS)
Takahashi, Yuichi; Sahara, Ryosuke; Konishi, Shogo; Goto, Takashi; Ogio, Shoichi
The data acquisition (DAQ) system for the surface detector (SD) arrays of TA×4 and TALE will be presented. Each SD records digital signals with 50 MHz FADCs and sends the data to a central communication center (of the "communication tower") via a wireless network system. The technique employed here is based on the currently-running DAQ system of the Telescope Array, and there are some improvements including i) replacement of a wireless LAN module with a custom protocol to another with TCP/IP, and ii) replacement of the "tower electronics" to a generic Linux board PC of Raspberry Pi Type II B. The details and performance of the new DAQ system are described below.
NASA Technical Reports Server (NTRS)
Watson, Leela R.; Bauman, William H., III
2008-01-01
Forecasters at the 45th Weather Squadron (45 WS) use observations from the Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS) wind tower network and the CCAFS (XMR) daily rawinsonde observations (RAOB) to issue and verify wind advisories and warnings for operations. These observations are also used by the National Weather Service (NWS) Spaceflight Meteorology Group (SMG) in Houston, Texas and the NWS Melbourne, Florida (NWS MLB) to initialize their locally-run mesoscale models. In addition, SMG uses these observations to support shuttle landings at the Shuttle Landing Facility (SLF). Due to impending budget cuts, some or all of the KSC/CCAFS wind towers on the east-central Florida mainland and the XMR RAOBs may be eliminated. The locations of the mainland towers and XMR RAOB site are shown in Figure I. The loss of these data may impact the forecast capability of the 45 WS, SMG and NWS MLB. The AMU was tasked to conduct an objective independent modeling study to help determine how important these observations are to the accuracy of the model output used by the forecasters. To accomplish this, the Applied Meteorology Unit (AMU) performed a sensitivity study using the Weather Research and Forecasting (WRF) model initialized with and without KSC/CCAFS wind tower and XMR RAOB data.
NASA Astrophysics Data System (ADS)
Chu, H.; Baldocchi, D. D.
2017-12-01
FLUXNET - the global network of eddy covariance tower sites provides valuable datasets of the direct and in situ measurements of fluxes and ancillary variables that are used across different disciplines and applications. Aerodynamic roughness (i.e., roughness length, zero plane displacement height) are one of the potential parameters that can be derived from flux-tower data and are crucial for the applications of land surface models and flux footprint models. As aerodynamic roughness are tightly associated with canopy structures (e.g., canopy height, leaf area), such parameters could potentially serve as an alternative metric for detecting the change of canopy structure (e.g., change of leaf areas in deciduous ecosystems). This study proposes a simple approach for deriving aerodynamic roughness from flux-tower data, and tests their suitability and robustness in detecting the seasonality of canopy structure. We run tests across a broad range of deciduous forests, and compare the seasonality derived from aerodynamic roughness (i.e., starting and ending dates of leaf-on period and peak-foliage period) against those obtained from remote sensing or in situ leaf area measurements. Our findings show aerodynamic roughness generally captures the timing of changes of leaf areas in deciduous forests. Yet, caution needs to be exercised while interpreting the absolute values of the roughness estimates.
2003-12-17
KENNEDY SPACE CENTER, FLA. -- The existing control tower seen here at the edge of the KSC Shuttle Landing Facility is being replaced. In use since 1987, the old tower stands only 20 feet above the runway surface, too low to see the launch pads to the east. During nighttime landing operations, those inside the tower have been hindered by the eight-billion candlepower xenon lights that illuminate the runway. The new control tower is built atop an existing mound, rising nearly 100 feet over the midpoint of the runway. The height gives controllers a spectacular 360-degree view of NASA-KSC and northern Brevard County. The new facility will also replace the SLF Operations Building. The operations building is home to the Military Radar Unit that monitors NASA-KSC airspace 24 hours a day, as well as runway light controls, navigational aids, weather and wind speed instrumentation, and gate controls. In the new tower, the computer displays will be fully modernized to Federal Aviation Administration standards with touch-screen technology. Construction on the new facility began in February 2003 and is nearly ready for occupancy. Only some final inspections and approvals remain. A support building and Public Affairs viewing deck, to be used for observing future landing operations, will be added and are already in work.
Free Fall Plasma-Arc Reactor for Synthesis of Carbon Nanotubes in Microgravity
NASA Technical Reports Server (NTRS)
Alford, J. M.; Mason, G. R.; Feinkema, D. A.
2006-01-01
High temperatures inside the plasma of a carbon arc generate strong buoyancy driven convection which has an effect on the growth and morphology of the single-walled carbon nanotubes (SWNTs). To study the effect of buoyancy on the arc process, a miniature carbon arc apparatus was designed and developed to synthesize SWNTs in a microgravity environment substantially free from buoyant convective flows. An arc reactor was operated in the 2.2- and 5.18-second drop towers at the NASA Glenn Research Center. The apparatus employed a 4 mm diameter anode and was powered by a portable battery pack capable of providing in excess of 300 amps at 30 volts to the arc for the duration of a 5-second drop. However, the principal result is that no dramatic difference in sample yield or composition was noted between normal gravity, 2.2-and 5-second long microgravity runs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Michel, D.; Jimenez, C.; Miralles, D. G.
The WAter Cycle Multi-mission Observation Strategy – EvapoTranspiration (WACMOS-ET) project has compiled a forcing data set covering the period 2005–2007 that aims to maximize the exploitation of European Earth Observations data sets for evapotranspiration (ET) estimation. The data set was used to run four established ET algorithms: the Priestley–Taylor Jet Propulsion Laboratory model (PT-JPL), the Penman–Monteith algorithm from the MODerate resolution Imaging Spectroradiometer (MODIS) evaporation product (PM-MOD), the Surface Energy Balance System (SEBS) and the Global Land Evaporation Amsterdam Model (GLEAM). In addition, in situ meteorological data from 24 FLUXNET towers were used to force the models, with results from both forcing sets compared tomore » tower-based flux observations. Model performance was assessed on several timescales using both sub-daily and daily forcings. The PT-JPL model and GLEAM provide the best performance for both satellite- and tower-based forcing as well as for the considered temporal resolutions. Simulations using the PM-MOD were mostly underestimated, while the SEBS performance was characterized by a systematic overestimation. In general, all four algorithms produce the best results in wet and moderately wet climate regimes. In dry regimes, the correlation and the absolute agreement with the reference tower ET observations were consistently lower. While ET derived with in situ forcing data agrees best with the tower measurements ( R 2 = 0.67), the agreement of the satellite-based ET estimates is only marginally lower ( R 2 = 0.58). Results also show similar model performance at daily and sub-daily (3-hourly) resolutions. Overall, our validation experiments against in situ measurements indicate that there is no single best-performing algorithm across all biome and forcing types. In conclusion, an extension of the evaluation to a larger selection of 85 towers (model inputs resampled to a common grid to facilitate global estimates) confirmed the original findings.« less
Michel, D.; Jimenez, C.; Miralles, D. G.; ...
2016-02-23
The WAter Cycle Multi-mission Observation Strategy – EvapoTranspiration (WACMOS-ET) project has compiled a forcing data set covering the period 2005–2007 that aims to maximize the exploitation of European Earth Observations data sets for evapotranspiration (ET) estimation. The data set was used to run four established ET algorithms: the Priestley–Taylor Jet Propulsion Laboratory model (PT-JPL), the Penman–Monteith algorithm from the MODerate resolution Imaging Spectroradiometer (MODIS) evaporation product (PM-MOD), the Surface Energy Balance System (SEBS) and the Global Land Evaporation Amsterdam Model (GLEAM). In addition, in situ meteorological data from 24 FLUXNET towers were used to force the models, with results from both forcing sets compared tomore » tower-based flux observations. Model performance was assessed on several timescales using both sub-daily and daily forcings. The PT-JPL model and GLEAM provide the best performance for both satellite- and tower-based forcing as well as for the considered temporal resolutions. Simulations using the PM-MOD were mostly underestimated, while the SEBS performance was characterized by a systematic overestimation. In general, all four algorithms produce the best results in wet and moderately wet climate regimes. In dry regimes, the correlation and the absolute agreement with the reference tower ET observations were consistently lower. While ET derived with in situ forcing data agrees best with the tower measurements ( R 2 = 0.67), the agreement of the satellite-based ET estimates is only marginally lower ( R 2 = 0.58). Results also show similar model performance at daily and sub-daily (3-hourly) resolutions. Overall, our validation experiments against in situ measurements indicate that there is no single best-performing algorithm across all biome and forcing types. In conclusion, an extension of the evaluation to a larger selection of 85 towers (model inputs resampled to a common grid to facilitate global estimates) confirmed the original findings.« less
Prueitt, M.L.
1994-02-08
Convection towers which are capable of cleaning the pollution from large quantities of air and of generating electricity utilize the evaporation of water sprayed into the towers to create strong airflows and to remove pollution from the air. Turbines in tunnels at the skirt section of the towers generate electricity. Other embodiments may also provide fresh water, and operate in an updraft mode. 5 figures.
Profiles of polychlorinated biphenyls (PCBs) in cement kilns co-processing solid waste.
Jin, Rong; Zhan, Jiayu; Liu, Guorui; Zhao, Yuyang; Zheng, Minghui; Yang, Lili; Wang, Mei
2017-05-01
Co-incineration of sewage sludge in cement kilns can be used for its disposal. In the present study, samples were collected from three cement production runs where sewage sludge and other wastes (e.g. municipal solid waste, waste acid and wet sewage sludge) were co-processed. The samples were analyzed for polychlorinated biphenyls (PCBs). The dioxin-like (dl)-PCB concentrations in the stack gases from run 1, 2, and 3 were 344.6, 548.7, and 104.3 pg m -3 , respectively. The toxic equivalency (TEQs) values for runs 1, 2, and 3 were 5.6, 8.9, and 0.7 pg TEQ Nm -3 , respectively. Calculation of net emissions for the three runs indicated that the co-incineration of other waste in addition to sewage sludge in cement kilns would not increase emission of the dl-PCBs. PCB concentrations in samples from the suspension boiler and humidifier tower, kiln-end bag filter, and cyclone preheater were much higher than those in samples from the kiln head area, indicating that these stages will be important for controlling PCB formation. Chlorinated biphenyl (CB)-77, CB-105 and CB-118 were the major dl-PCB congeners, CB-52, CB-101 were the major indicator PCB congeners, and tetra-CB to hexa-CB were the major homologues for the total input or output materials. Copyright © 2017 Elsevier Ltd. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-22
... From the People's Republic of China: Alignment of Final Countervailing Duty Determination With Final... People's Republic of China (PRC) with the final determination in the companion antidumping duty (AD..., 14th Street and Constitution Avenue NW., Washington, DC 20230; telephone: 202-482-4793 and 202-482-1503...
Antenna structures and cloud-to-ground lightning location: 1995-2015
NASA Astrophysics Data System (ADS)
Kingfield, Darrel M.; Calhoun, Kristin M.; de Beurs, Kirsten M.
2017-05-01
Spatial analyses of cloud-to-ground (CG) lightning occurrence due to a rapid expansion in the number of antenna towers across the United States are explored by gridding 20 years of National Lightning Detection Network data at 500 m spatial resolution. The 99.8% of grid cells with ≥100 CGs were within 1 km of an antenna tower registered with the Federal Communications Commission. Tower height is positively correlated with CG occurrence; towers taller than 400 m above ground level experience a median increase of 150% in CG lightning density compared to a region 2 km to 5 km away. In the northern Great Plains, the cumulative CG lightning density near the tower was around 138% (117%) higher than a region 2 to 5 km away in the September-February (March-August) months. Higher CG frequencies typically also occur in the first full year following new tower construction, creating new lightning hot spots.
Surface and Tower Meteorological Instrumentation at NSA Handbook - January 2006
DOE Office of Scientific and Technical Information (OSTI.GOV)
MT Ritsche
2006-01-30
The Surface and Tower Meteorological Instrumentation at Atqasuk (METTWR2H) uses mainly conventional in situ sensors to measure wind speed, wind direction, air temperature, dew point and humidity mounted on a 10-m tower. It also obtains barometric pressure, visibility, and precipitation data from sensors at or near the base of the tower. In addition, a Chilled Mirror Hygrometer is located at 1 m for comparison purposes. Temperature and relative humidity probes are mounted at 2 m and 5 m on the tower. For more information, see the Surface and Tower Meteorological Instrumentation at Atqasuk Handbook.
Special Inspector General for Iraq Reconstruction (SIGIR): The Year of Transition in Review
2007-01-30
border forts have been constructed thus far, and 5 points of entry have been completed.315 SIGIR’s ground project surveys inspected 21 border forts and...Gen. Dempsey recently estimated that 20-25% of the National Police “needed to be weeded out.”367 Finally, recent surveys suggest that public...Transportation and Communications system, 33 site surveys have been completed for the communication towers between Mosul and Basrah.409 Phase II
Wave Energy from the North Sea: Experiences from the Lysekil Research Site
NASA Astrophysics Data System (ADS)
Leijon, Mats; Boström, Cecilia; Danielsson, Oskar; Gustafsson, Stefan; Haikonen, Kalle; Langhamer, Olivia; Strömstedt, Erland; Stålberg, Magnus; Sundberg, Jan; Svensson, Olle; Tyrberg, Simon; Waters, Rafael
2008-05-01
This paper provides a status update on the development of the Swedish wave energy research area located close to Lysekil on the Swedish West coast. The Lysekil project is run by the Centre for Renewable Electric Energy Conversion at Uppsala University. The project was started in 2004 and currently has permission to run until the end of 2013. During this time period 10 grid-connected wave energy converters, 30 buoys for studies on environmental impact, and a surveillance tower for monitoring the interaction between waves and converters will be installed and studied. To date the research area holds one complete wave energy converter connected to a measuring station on shore via a sea cable, a Wave Rider™ buoy for wave measurements, 25 buoys for studies on environmental impact, and a surveillance tower. The wave energy converter is based on a linear synchronous generator which is placed on the sea bed and driven by a heaving point absorber at the ocean surface. The converter is directly driven, i.e. it has no gearbox or other mechanical or hydraulic conversion system. This results in a simple and robust mechanical system, but also in a somewhat more complicated electrical system.
Pay attention to reflux/feed entry design
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fleming, B.; Martin, G.R.; Hartman, E.L.
1996-01-01
Trays generally are forgiving pieces of equipment and can conceal the effects of poorly designed feed and reflux entries. When one tries to push a tower to its hydraulic limit, however, poor entry design can penalize the performance of the trays and result in a lower final capacity. Normally, new towers are not as susceptible to entry design problems as ones being revamped. This is because new towers usually have some degree of capacity oversizing.Standard design practices used for new columns having spare capacity, though, may not be suitable for revamped towers. In this article, the authors detail the basicmore » principles of reflux and feed entry design, good practices to follow, and poor practices to avoid. They also include a case study of a large-diameter light hydrocarbon splitter revamped with high capacity trays to illustrate the potential pitfalls associated with incorrectly designed reflux and feed entry arrangements.« less
NASA Astrophysics Data System (ADS)
Cao, Y.; Cervone, G.; Barkley, Z.; Lauvaux, T.; Deng, A.; Miles, N.; Richardson, S.
2016-12-01
Fugitive methane emission rates for the Marcellus shale area are estimated using a genetic algorithm that finds optimal weights to minimize the error between simulated and observed concentrations. The overall goal is to understand the relative contribution of methane due to Shale gas extraction. Methane sensors were installed on four towers located in northeastern Pennsylvania to measure atmospheric concentrations since May 2015. Inverse Lagrangian dispersion model runs are performed from each of these tower locations for each hour of 2015. Simulated methane concentrations at each of the four towers are computed by multiplying the resulting footprints from the atmospheric simulations by thousands of emission sources grouped into 11 classes. The emission sources were identified using GIS techniques, and include conventional and unconventional wells, different types of compressor stations, pipelines, landfills, farming and wetlands. Initial estimates for each source are calculated based on emission factors from EPA and few regional studies. A genetic algorithm is then used to identify optimal emission rates for the 11 classes of methane emissions and to explore extreme events and spatial and temporal structures in the emissions associated with natural gas activities.
Large eddy simulation for atmospheric boundary layer flow over flat and complex terrains
NASA Astrophysics Data System (ADS)
Han, Yi; Stoellinger, Michael; Naughton, Jonathan
2016-09-01
In this work, we present Large Eddy Simulation (LES) results of atmospheric boundary layer (ABL) flow over complex terrain with neutral stratification using the OpenFOAM-based simulator for on/offshore wind farm applications (SOWFA). The complete work flow to investigate the LES for the ABL over real complex terrain is described including meteorological-tower data analysis, mesh generation and case set-up. New boundary conditions for the lateral and top boundaries are developed and validated to allow inflow and outflow as required in complex terrain simulations. The turbulent inflow data for the terrain simulation is generated using a precursor simulation of a flat and neutral ABL. Conditionally averaged met-tower data is used to specify the conditions for the flat precursor simulation and is also used for comparison with the simulation results of the terrain LES. A qualitative analysis of the simulation results reveals boundary layer separation and recirculation downstream of a prominent ridge that runs across the simulation domain. Comparisons of mean wind speed, standard deviation and direction between the computed results and the conditionally averaged tower data show a reasonable agreement.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1994-09-01
This final report from VFL Technologies for the pilot-scale thermal treatment of lower East Fork Poplar Creek floodplain soils dated September 1994 contains LEFPC Appendices, Volume 5, Appendix V - D. This appendix includes the final verification run data package (PAH, TCLP herbicides, TCLP pesticides).
2009-02-12
CAPE CANAVERAL, Fla. – A lightning mast remains to be lifted atop the third and final lightning tower erected on Launch Pad 39B at NASA's Kennedy Space Center. Three towers surround the pad. The new lightning protection system is being built for the Constellation Program and Ares/Orion launches. Each of the towers is 500 feet tall with an additional 100-foot fiberglass mast atop supporting a wire catenary system. This improved lightning protection system allows for the taller height of the Ares I rocket compared to the space shuttle. Pad 39B will be the site of the first Ares vehicle launch, including the Ares I-X test flight that is targeted for July 2009. Photo credit: NASA/Jack Pfaller
MOD-5A wind turbine generator program design report: Volume 1: Executive Summary
NASA Technical Reports Server (NTRS)
1984-01-01
The design, development and analysis of the 7.3 MW MOD-5A wind turbine generator covering work performed between July 1980 and June 1984 is discussed. The report is divided into four volumes: Volume 1 summarizes the entire MOD-5A program, Volume 2 discusses the conceptual and preliminary design phases, Volume 3 describes the final design of the MOD-5A, and Volume 4 contains the drawings and specifications developed for the final design. Volume 1, the Executive Summary, summarizes all phases of the MOD-5A program. The performance and cost of energy generated by the MOD-5A are presented. Each subsystem - the rotor, drivetrain, nacelle, tower and foundation, power generation, and control and instrumentation subsystems - is described briefly. The early phases of the MOD-5A program, during which the design was analyzed and optimized, and new technologies and materials were developed, are discussed. Manufacturing, quality assurance, and safety plans are presented. The volume concludes with an index of volumes 2 and 3.
Design and Evaluation of Glass/epoxy Composite Blade and Composite Tower Applied to Wind Turbine
NASA Astrophysics Data System (ADS)
Park, Hyunbum
2018-02-01
In the study, the analysis and manufacturing of small class wind turbine blade was performed. In the structural design, firstly the loading conditions are defined through the load case analysis. The proposed structural configuration of blade has a sandwich type composite structure with the E-glass/Epoxy face sheets and the Urethane foam core for lightness, structural stability, low manufacturing cost and easy manufacturing process. And also, this work proposes a design procedure and results of tower for the small scale wind turbine systems. Structural analysis of blade including load cases, stress, deformation, buckling, vibration and fatigue life was performed using the finite element method, the load spectrum analysis and the Miner rule. Moreover, investigation on structural safety of tower was verified through structural analysis by FEM. The manufacturing of blade and tower was performed based on structural design. In order to investigate the designed structure, the structural tests were conducted and its results were compared with the calculated results. It is confirmed that the final proposed blade and tower meet the design requirements.
Developer view of the CSP evolution
NASA Astrophysics Data System (ADS)
Carvajal, Javier López; Barea, Jose M.; Barragan, Jose; Altmann, Thomas
2017-06-01
This paper briefly describes the history of CSP up to the present times and also gives some views about what could be expected in the near future for the industry. It also points out the relevance of the TES system as a key and gives some ideas regarding the innovations that could be expected in the coming CSP projects. Although currently, tower technology capacity under operation is less than 15% of the total CSP capacity in the world, solar tower, with molten salt most likely, might be the predominant technology in the medium run for electricity generation. In addition, other different concepts will be more commonly projected in order to increase dispatchability or renewable energy contribution in the electric system as hybridization with other technologies like PV or as part of desalination projects.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wendt, Fabian F; Robertson, Amy N; Jonkman, Jason
During the course of the Offshore Code Comparison Collaboration, Continued, with Correlation (OC5) project, which focused on the validation of numerical methods through comparison against tank test data, the authors created a numerical FAST model of the 1:50-scale DeepCwind semisubmersible system that was tested at the Maritime Research Institute Netherlands ocean basin in 2013. This paper discusses several model calibration studies that were conducted to identify model adjustments that improve the agreement between the numerical simulations and the experimental test data. These calibration studies cover wind-field-specific parameters (coherence, turbulence), hydrodynamic and aerodynamic modeling approaches, as well as rotor model (blade-pitchmore » and blade-mass imbalances) and tower model (structural tower damping coefficient) adjustments. These calibration studies were conducted based on relatively simple calibration load cases (wave only/wind only). The agreement between the final FAST model and experimental measurements is then assessed based on more-complex combined wind and wave validation cases.« less
Kay, E J
2003-03-22
Everyone who is in business knows that the most important thing one can achieve is attracting and retaining customers. Now, before the BDJ is bombarded with complaints about ivory-tower academics talking theoretically about something of which they have no experience, I need to tell you that I do have real, live practical experience of business. Okay, it's not a business to do with dentistry, it's a business to do with horses, but nevertheless, it is a business and the basic premises of businesses apply to both dentistry and to riding stables. Remarkably also, there are a number of interesting analogies between running a riding school and running a dental practice!
5. Keeper's house and light tower, view south southwest, east ...
5. Keeper's house and light tower, view south southwest, east and north sides - Rockland Breakwater Light Station, At end of granite breakwater extending south from Jameson Point, Rockland, Knox County, ME
5. Light tower, newel post and stairs, looking east ...
5. Light tower, newel post and stairs, looking east - Great Duck Island Light Station, At southern tip of Great Duck Island southeast of Bass Harbor & northeast of Frenchboro, Frenchboro, Hancock County, ME
Enhanced Precision Geolocation in 4G Wireless Networks
2013-03-01
years has implemented a National Emergency Warning System using text messages delivered to cell phones [5]. The November 1999 FCC E911 regulations...statistical theory of passive geolocation of emitters may be found in [18]. Papers that survey methods of geolocation applied to cell phones include [4...where to put the tower % n: which tower to place %randomTowers(obj,dispersion, seperation ): generates % random towers for the network % obj: the network
Pasta nucleosynthesis: Molecular dynamics simulations of nuclear statistical equilibrium
NASA Astrophysics Data System (ADS)
Caplan, M. E.; Schneider, A. S.; Horowitz, C. J.; Berry, D. K.
2015-06-01
Background: Exotic nonspherical nuclear pasta shapes are expected in nuclear matter at just below saturation density because of competition between short-range nuclear attraction and long-range Coulomb repulsion. Purpose: We explore the impact nuclear pasta may have on nucleosynthesis during neutron star mergers when cold dense nuclear matter is ejected and decompressed. Methods: We use a hybrid CPU/GPU molecular dynamics (MD) code to perform decompression simulations of cold dense matter with 51 200 and 409 600 nucleons from 0.080 fm-3 down to 0.00125 fm-3 . Simulations are run for proton fractions YP= 0.05, 0.10, 0.20, 0.30, and 0.40 at temperatures T = 0.5, 0.75, and 1.0 MeV. The final composition of each simulation is obtained using a cluster algorithm and compared to a constant density run. Results: Size of nuclei in the final state of decompression runs are in good agreement with nuclear statistical equilibrium (NSE) models for temperatures of 1 MeV while constant density runs produce nuclei smaller than the ones obtained with NSE. Our MD simulations produces unphysical results with large rod-like nuclei in the final state of T =0.5 MeV runs. Conclusions: Our MD model is valid at higher densities than simple nuclear statistical equilibrium models and may help determine the initial temperatures and proton fractions of matter ejected in mergers.
Final Environmental Assessment- Air Traffic Control Tower and Fire Station Pope AFB, NC
2004-06-01
collection of information if it does not display a currently valid OMB control number. 1. REPORT DATE JUN 2004 2. REPORT TYPE 3. DATES COVERED 00-00...of undeveloped land are located east of the base. Pope AFB covers approximately 2,140 acres, of which 151 acres are owned by the Air Force. The...protection against decreased visibility and damage to animals, crops , vegetation, and buildings. 4 PM2.s = Particulate matter less than 2.5 microns in
Quantifying the local influence at a tall tower site in nocturnal conditions
Werth, David; Buckley, Robert; Zhang, Gengsheng; ...
2015-10-17
The influence of the local terrestrial environment on nocturnal atmospheric CO 2 measurements at a 329-m television transmitter tower (and a component of a CO 2 monitoring network) was estimated in this paper with a tracer release experiment and a subsequent simulation of the releases. This was done to characterize the vertical transport of emissions from the surface to the uppermost tower level and how it is affected by atmospheric stability. The tracer release experiment was conducted over two nights in May of 2009 near the Department of Energy’s Savannah River Site (SRS) in South Carolina. Tracer was released onmore » two contrasting nights—slightly stable and moderately stable—from several upwind surface locations. Measurements at the 329-m level on both nights indicate that tracer was able to mix vertically within a relatively short (~24 km) distance, implying that nocturnal stable conditions do not necessarily prevent vertical dispersion in the boundary layer and that CO 2 measurements at the tower are at least partly influenced by nearby emissions. A simulation of the tracer release is used to calculate the tower footprint on the two nights to estimate the degree to which the local domain affects the tower readings. The effect of the nocturnal boundary layer on the area sampled by the tower can be seen clearly, as the footprints were affected by changes in stability. Finally, the contribution of local sources to the measurements at the tower was minimal, however, suggesting that nocturnal concentrations at upper levels are contributed mostly by regional sources.« less
Quantifying the local influence at a tall tower site in nocturnal conditions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Werth, David; Buckley, Robert; Zhang, Gengsheng
The influence of the local terrestrial environment on nocturnal atmospheric CO 2 measurements at a 329-m television transmitter tower (and a component of a CO 2 monitoring network) was estimated in this paper with a tracer release experiment and a subsequent simulation of the releases. This was done to characterize the vertical transport of emissions from the surface to the uppermost tower level and how it is affected by atmospheric stability. The tracer release experiment was conducted over two nights in May of 2009 near the Department of Energy’s Savannah River Site (SRS) in South Carolina. Tracer was released onmore » two contrasting nights—slightly stable and moderately stable—from several upwind surface locations. Measurements at the 329-m level on both nights indicate that tracer was able to mix vertically within a relatively short (~24 km) distance, implying that nocturnal stable conditions do not necessarily prevent vertical dispersion in the boundary layer and that CO 2 measurements at the tower are at least partly influenced by nearby emissions. A simulation of the tracer release is used to calculate the tower footprint on the two nights to estimate the degree to which the local domain affects the tower readings. The effect of the nocturnal boundary layer on the area sampled by the tower can be seen clearly, as the footprints were affected by changes in stability. Finally, the contribution of local sources to the measurements at the tower was minimal, however, suggesting that nocturnal concentrations at upper levels are contributed mostly by regional sources.« less
Microwave Tower Deflection Monitor
NASA Astrophysics Data System (ADS)
Truax, Bruce E.
1980-10-01
This paper describes an instrument which is capable of monitoring both the twist and lateral motion of a microwave tower. The Microwave Tower Deflection Monitor (MTDM) gives designers the capability of evaluating towers, both for troubleshooting purposes and comparison with design theory. The MTDM has been designed to operate on a broad range of tower structures in a variety of weather conditions. The instrument measures tower motion by monitoring the position of two retroreflectors mounted on the top of the tower. The two retroreflectors are located by scanning a laser beam in a raster pattern in the vicinity of the reflector. When a retroreflector is struck its position is read by a microprocessor and stored on a magnetic tape. Position resolution of better than .5 cm at 200 ft. has been observed in actual tests.
Research and application of multi-agent genetic algorithm in tower defense game
NASA Astrophysics Data System (ADS)
Jin, Shaohua
2018-04-01
In this paper, a new multi-agent genetic algorithm based on orthogonal experiment is proposed, which is based on multi-agent system, genetic algorithm and orthogonal experimental design. The design of neighborhood competition operator, orthogonal crossover operator, Son and self-learning operator. The new algorithm is applied to mobile tower defense game, according to the characteristics of the game, the establishment of mathematical models, and finally increases the value of the game's monster.
2009-07-01
including suggestions for reducing this burden, to Washington Headquarters Services, Directorate for Information Operations and Reports, 1215...Canaveral Air Force Station (CCAFS) Skid Strip. Since the facility no longer operates as a missile skid strip, it is referred to as the "Airfield...construction of a new 65 foot tall control tower; construction of a new Airfield Manager (AM) Operations Building that would adjoin the new tower; and
NASA Astrophysics Data System (ADS)
Xu, Y.; Huang, M.; Keller, M. M.; Longo, M.; Knox, R. G.; Koven, C.; Fisher, R.
2016-12-01
As a key component in the climate system, old-growth tropical forests act as carbon sinks that remove CO2 from the atmosphere. However, these forests could be easily turned into C sources when disturbed. In fact, over half of tropical forests have been cleared or logged, and almost half of standing primary tropical forests are designated for timber production. Existing literature suggests that timber harvests alone could contribute up to 25% as much C losses as deforestation in Amazon. Yet, the spatial extent and recovery trajectory of disturbed forests in a changing climate are highly uncertain. This study constitutes our first attempt to quantify impacts of selective logging on water, energy, and carbon budgets in Amazon forests using the Functionally Assembled Terrestrial Ecosystem Simulator (FATES). The Community Land Model version 4.5 (CLM4.5), with and without FATES turned on, are configured to run at two flux towers established in the Large Scale Biosphere-Atmosphere Experiment in Amazonia (LBA). One tower is located at in an old-growth forest (i.e. KM67) and the other is located in a selectively logged site (i.e., KM83). The three CLM4.5 options, (1) Satellite Phenology (CLM4.5-SP), (2) Century-based biogeochemical cycling with prognostic phenology (CLM4.5-BGC), and (3) CLM4.5-FATES, are spun up to equilibrium by recycling the observed meteorology at the towers, respectively. The simulated fluxes (i.e., sensible heat, latent heat, and net ecosystem exchange) are then compared to observations at KM67 to evaluate the capability of the models in capturing water and carbon dynamics in old-growth tropical forests. Our results suggest that all three models perform reasonably well in capturing the fluxes but demographic features simulated by FATES, such as distributions of diameter at breast height (DBH) and stem density (SD), are skewed heavily toward extremely large trees (e.g., > 100 cm in DBH) when compared to site surveys at the forest plots. Efforts are underway to evaluate parametric sensitivity in FATES to improve simulations in old-growth forests, and to implement parameterization to represent pulse disturbance to carbon pools created by logging events at different intensities, and follow-up recovery closely related to gap-phase regeneration and competition for lights within the gaps.
NASA Technical Reports Server (NTRS)
Bauman, William H., III
2010-01-01
The 12-km resolution North American Mesoscale (NAM) model (MesoNAM) is used by the 45th Weather Squadron (45 WS) Launch Weather Officers at Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS) to support space launch weather operations. The 45 WS tasked the Applied Meteorology Unit to conduct an objective statistics-based analysis of MesoNAM output compared to wind tower mesonet observations and then develop a an operational tool to display the results. The National Centers for Environmental Prediction began running the current version of the MesoNAM in mid-August 2006. The period of record for the dataset was 1 September 2006 - 31 January 2010. The AMU evaluated MesoNAM hourly forecasts from 0 to 84 hours based on model initialization times of 00, 06, 12 and 18 UTC. The MesoNAM forecast winds, temperature and dew point were compared to the observed values of these parameters from the sensors in the KSC/CCAFS wind tower network. The data sets were stratified by model initialization time, month and onshore/offshore flow for each wind tower. Statistics computed included bias (mean difference), standard deviation of the bias, root mean square error (RMSE) and a hypothesis test for bias = O. Twelve wind towers located in close proximity to key launch complexes were used for the statistical analysis with the sensors on the towers positioned at varying heights to include 6 ft, 30 ft, 54 ft, 60 ft, 90 ft, 162 ft, 204 ft and 230 ft depending on the launch vehicle and associated weather launch commit criteria being evaluated. These twelve wind towers support activities for the Space Shuttle (launch and landing), Delta IV, Atlas V and Falcon 9 launch vehicles. For all twelve towers, the results indicate a diurnal signal in the bias of temperature (T) and weaker but discernable diurnal signal in the bias of dewpoint temperature (T(sub d)) in the MesoNAM forecasts. Also, the standard deviation of the bias and RMSE of T, T(sub d), wind speed and wind direction indicated the model error increased with the forecast period all four parameters. The hypothesis testing uses statistics to determine the probability that a given hypothesis is true. The goal of using the hypothesis test was to determine if the model bias of any of the parameters assessed throughout the model forecast period was statistically zero. For th is dataset, if this test produced a value >= -1 .96 or <= 1.96 for a data point, then the bias at that point was effectively zero and the model forecast for that point was considered to have no error. A graphical user interface (GUI) was developed so the 45 WS would have an operational tool at their disposal that would be easy to navigate among the multiple stratifications of information to include tower locations, month, model initialization times, sensor heights and onshore/offshore flow. The AMU developed the GUI using HyperText Markup Language (HTML) so the tool could be used in most popular web browsers with computers running different operating systems such as Microsoft Windows and Linux.
Concentrating Solar Power Projects - Sierra SunTower | Concentrating Solar
Turbine Capacity: Net: 5.0 MW Gross: 5.0 MW Status: Currently Non-Operational Start Year: 2009 Do you have more information, corrections, or comments? Background Technology: Power tower Status: Currently Non
5. Light tower and corner of keeper's house, view northeast, ...
5. Light tower and corner of keeper's house, view northeast, northwest and southwest sides - Baker Island Light, Lightkeeper's House, Just east of Cranberry Isles, at entrance to Frenchman Bay, Bar Harbor, Hancock County, ME
5. STEAM PLANT COOLING TOWER LOCATED WEST OF STEAM PLANT ...
5. STEAM PLANT COOLING TOWER LOCATED WEST OF STEAM PLANT BUILDING, FROM SOUTH. SHOWS CURRENT LEVEL OF DISREPAIR. December 4, 1990 - Crosscut Steam Plant, North side Salt River near Mill Avenue & Washington Street, Tempe, Maricopa County, AZ
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arends, J.; Sandusky, William F.
2010-03-31
This report represents findings of a design review team that evaluated construction documents (at the 100% level) and operating specifications for a new control tower and support building that will be built in Palm Springs, California by the Federal Aviation Administration (FAA). The focus of the review was to identify measures that could be incorporated into the final design and operating specifications that would result in additional energy savings for the FAA that would not have otherwise occurred.
Wind turbine model and loop shaping controller design
NASA Astrophysics Data System (ADS)
Gilev, Bogdan
2017-12-01
A model of a wind turbine is evaluated, consisting of: wind speed model, mechanical and electrical model of generator and tower oscillation model. Model of the whole system is linearized around of a nominal point. By using the linear model with uncertainties is synthesized a uncertain model. By using the uncertain model is developed a H∞ controller, which provide mode of stabilizing the rotor frequency and damping the tower oscillations. Finally is simulated work of nonlinear system and H∞ controller.
NASA Technical Reports Server (NTRS)
Hall, Nancy R.; Stocker, Dennis P.; DeLombard, Richard
2011-01-01
This paper describes two student competition programs that allow student teams to conceive a science or engineering experiment for a microgravity environment. Selected teams design and build their experimental hardware, conduct baseline tests, and ship their experiment to NASA where it is operated in the 2.2 Second Drop Tower. The hardware and acquired data is provided to the teams after the tests are conducted so that the teams can prepare their final reports about their findings.
Geology of Devils Tower National Monument, Wyoming
Robinson, Charles Sherwood
1956-01-01
Devils Tower is a steep-sided mass of igneous rock that rises above the surrounding hills and the valley of the Belle Fourche River in Crook County, Wyo. It is composed of a crystalline rock, classified as phonolite porphyry, that when fresh is gray but which weathers to green or brown. Vertical joints divide the rock mass into polygonal columns that extend from just above the base to the top of the Tower. The hills in the vicinity and at the base of the Tower are composed of red, yellow, green, or gray sedimentary rocks that consist of sandstone, shale, or gypsum. These rocks, in aggregate about 400 feet thick, include, from oldest to youngest, the upper part of the Spearfish formation, of Triassic age, the Gypsum Spring formation, of Middle Jurassic age, and the Sundance formation, of Late Jurassic age. The Sundance formation consists of the Stockade Beaver shale member, the Hulett sandstone member, the Lak member, and the Redwater shale member. The formations have been only slightly deformed by faulting and folding. Within 2,000 to 3.000 feet of the Tower, the strata for the most part dip at 3 deg - 5 deg towards the Tower. Beyond this distance, they dip at 2 deg - 5 deg from the Tower. The Tower is believed to have been formed by the intrusion of magma into the sedimentary rocks, and the shape of the igneous mass formed by the cooled magma is believed to have been essentially the same as the Tower today. Devils Tower owes its impressiveness to its resistance to erosion as compared with the surrounding sedimentary rocks, and to the contrast of the somber color of the igneous column to the brightly colored bands of sedimentary rocks.
Tower Based Load Measurements for Individual Pitch Control and Tower Damping of Wind Turbines
NASA Astrophysics Data System (ADS)
Kumar, A. A.; Hugues-Salas, O.; Savini, B.; Keogh, W.
2016-09-01
The cost of IPC has hindered adoption outside of Europe despite significant loading advantages for large wind turbines. In this work we presented a method for applying individual pitch control (including for higher-harmonics) using tower-top strain gauge feedback instead of blade-root strain gauge feedback. Tower-top strain gauges offer hardware savings of approximately 50% in addition to the possibility of easier access for maintenance and installation and requiring a less specialised skill-set than that required for applying strain gauges to composite blade roots. A further advantage is the possibility of using the same tower-top sensor array for tower damping control. This method is made possible by including a second order IPC loop in addition to the tower damping loop to reduce the typically dominating 3P content in tower-top load measurements. High-fidelity Bladed simulations show that the resulting turbine spectral characteristics from tower-top feedback IPC and from the combination of tower-top IPC and damping loops largely match those of blade-root feedback IPC and nacelle- velocity feedback damping. Lifetime weighted fatigue analysis shows that the methods allows load reductions within 2.5% of traditional methods.
5. SWITCH TOWER AND JUNCTION OF S.A.R. #1 & S.A.R. ...
5. SWITCH TOWER AND JUNCTION OF S.A.R. #1 & S.A.R. #2 TRANSMISSION LINES, MARCH 7, 1916. SCE drawing no. 4932. - Santa Ana River Hydroelectric System, Transmission Lines, Redlands, San Bernardino County, CA
5. View of east elevation of fuel tanks, radar tower ...
5. View of east elevation of fuel tanks, radar tower and power plant in background, looking west - Naval Air Station Fallon, Fuel Tanks, 800 Complex, off Carson Road near intersection of Pasture & Berney Roads, Fallon, Churchill County, NV
Tornado Strikes Southern Maryland
NASA Technical Reports Server (NTRS)
2002-01-01
Evening light catches the tops of towering thunderheads over the Mid-Atlantic states on April 28, 2002. The powerful storms spawned several tornados, one of which was classified as an F4 tornado. The powerful tornado touched down in the southern Maryland town of La Plata, destroying most of the historic downtown. The twister-one of the strongest ever to hit the state-beat a 24-mile swath running west to east through the state and claimed at least three lives. The image above was taken by the Geostationary Operational Environmental Satellite (GOES) at 7:15 PM Eastern Daylight Savings Time. A large version of the animation shows more detail. (5.9 MB Quicktime) Image courtesy National Oceanic and Atmospheric Administration (NOAA) and the GOES Project Science Office. Animation by Robert Simmon, NASA GSFC.
Changes in Running Mechanics During a 6-Hour Running Race.
Giovanelli, Nicola; Taboga, Paolo; Lazzer, Stefano
2017-05-01
To investigate changes in running mechanics during a 6-h running race. Twelve ultraendurance runners (age 41.9 ± 5.8 y, body mass 68.3 ± 12.6 kg, height 1.72 ± 0.09 m) were asked to run as many 874-m flat loops as possible in 6 h. Running speed, contact time (t c ), and aerial time (t a ) were measured in the first lap and every 30 ± 2 min during the race. Peak vertical ground-reaction force (F max ), stride length (SL), vertical downward displacement of the center of mass (Δz), leg-length change (ΔL), vertical stiffness (k vert ), and leg stiffness (k leg ) were then estimated. Mean distance covered by the athletes during the race was 62.9 ± 7.9 km. Compared with the 1st lap, running speed decreased significantly from 4 h 30 min onward (mean -5.6% ± 0.3%, P < .05), while t c increased after 4 h 30 min of running, reaching the maximum difference after 5 h 30 min (+6.1%, P = .015). Conversely, k vert decreased after 4 h, reaching the lowest value after 5 h 30 min (-6.5%, P = .008); t a and F max decreased after 4 h 30 min through to the end of the race (mean -29.2% and -5.1%, respectively, P < .05). Finally, SL decreased significantly (-5.1%, P = .010) during the last hour of the race. Most changes occurred after 4 h continuous self-paced running, suggesting a possible time threshold that could affect performance regardless of absolute running speed.
Furnari, Melody A; Jobes, Michelle L; Nekrasova, Tanya; Minden, Audrey; Wagner, George C
2014-04-01
PAK5 and PAK6 are protein kinases highly expressed in the brain. Previously, we observed that Pak6 knockout mice gained significantly more weight during development than Pak5 knockout mice as well as wild-type controls and double-knockout mice lacking both Pak5 and Pak6. In this study, we assessed the effects of exercise on food intake and weight gain of these mice as well as their sensitivity to the stimulant effects of amphetamine. Mice of each genotype were placed in cages with free access to run wheel exercise or in cages without run wheels for a total of 74 days. Food and fluid intake as well as body weight of each mouse were measured on a weekly basis. Finally, mice were given a high dose of amphetamine and activity levels were observed immediately thereafter for 90 minutes. Brains and testes of mice were assayed for protein levels of the estrogen alpha and progesterone receptors. While run wheel mice consumed significantly more food, they weighed less than non-run wheel mice. In addition, although Pak6 knockout mice consumed the same amount of food as wild-type mice, they were significantly heavier regardless of run wheel condition. Pak5 knockout mice were found to be more active than other genotypes after amphetamine treatment. Finally, protein levels of the progesterone and estrogen alpha receptors were altered in brain and testes of the Pak6 knockout mice. Collectively, these data suggest that PAK6 play a role in weight gain unrelated to exercise and caloric intake and that Pak5 knockout mice are more sensitive to the stimulant effects of amphetamine.
NASA Technical Reports Server (NTRS)
Adams, M. L.; Hagyard, M. J.; West, E. A.; Smith, J. E.; Whitaker, Ann F. (Technical Monitor)
2001-01-01
The Marshall Space Flight Center's (MSFC) solar group announces the successful upgrade of our tower vector magnetograph. In operation since 1973, the last major alterations to the system (which includes telescope, filter, polarizing optics, camera, and data acquisition computer) were made in 1982, when we upgraded from an SEC Vidicon camera to a CCD. In 1985, other changes were made which increased the field-of-view from 5 x 5 arc min (2.4 arc sec per pixel) to 6 x 6 arc min with a resolution of 2.81 arc sec. In 1989, the Apollo Telescope Mount H-alpha telescope was coaligned with the optics of the magnetograph. The most recent upgrades (year 2000), funded to support the High Energy Solar Spectroscopic Imager (HESSI) mission, have resulted in a pixel size of 0.64 arc sec over a 7 x 5.2 arc min field-of-view (binning 1x1). This poster describes the physical characteristics of the new system and compares spatial resolution, timing, and versatility with the old system. Finally, we provide a description of our Internet web site, which includes images of our most recent observations, and links to our data archives, as well as the history of magnetography at MSFC and education outreach pages.
Legionella species colonization in cooling towers: risk factors and assessment of control measures.
Mouchtouri, Varvara A; Goutziana, Georgia; Kremastinou, Jenny; Hadjichristodoulou, Christos
2010-02-01
Cooling towers can be colonized by Legionella spp, and inhalation of aerosols generated by their operation may cause Legionnaires' disease in susceptible hosts. Environmental investigations of Legionnaires' disease outbreaks linked with cooling towers have revealed poorly maintained systems, lack of control measures, and failure of system equipment. The purpose of this study was to identify Legionella-contaminated cooling towers, identify risk factors for contamination, and assess the effectiveness of control measures. A total of 96 cooling towers of public buildings were registered and inspected, and 130 samples were collected and microbiologically tested. Microbiological test results were associated with characteristics of cooling towers, water samples, inspection results, and maintenance practices. Of the total 96 cooling towers examined, 47 (48.9%) were colonized by Legionella spp, and 22 (22.9%) required remedial action. A total of 65 samples (50.0%) were positive (> or = 500 cfu L(-1)), and 30 (23%) were heavily contaminated (> or = 10(4) cfu L(-1)). Of the 69 isolates identified, 55 strains (79.7.%) were L pneumophila. Legionella colonization was positively associated with the absence of training on Legionella control (relative risk [RR] = 1.66; P = .02), absence of regular Legionella testing (RR = 2.07: P = .002), absence of sunlight protection (RR = 1.63: P = .02), with samples in which the free residual chlorine level in the water sample was < 0.5 mg/L (RR = 2.23; P = .01), and with total plate count (P =.001). Colonization was negatively associated with chemical disinfection (RR = 0.2; P = .0003) and with the presence of a risk assessment and management plan (RR = 0.12; P = .0005). A statistically significant higher age (P =.01) was found in legionellae-positive cooling towers (median, 17 years; interquartile range [IQR] =5.0 to 26.0 years) compared with noncolonized cooling towers (median age, 6 years; IQR =1.0 to 13.5 years). After the 22 legionellae-positive cooling towers were disinfected with chlorine, 2 (9%) of them remained positive for Legionella spp with a concentration > or = 1000 cfu L(-1). Cooling towers can be heavily colonized by Legionella spp and thus present a potential risk for infection. This study demonstrates the importance of a risk assessment and management plan. Water chlorination effectively reduces legionellae contamination. Proper training of cooling tower operators is paramount. Copyright 2010 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
Sanchez, Inma; Garcia-Nuñez, Marian; Ragull, Sonia; Sopena, Nieves; Pedro-Botet, Maria Luisa; Estere, Maria; Rey-Joly, Celestino; Sabria, Miquel; Esteve, Maria
2008-02-01
Genotypic variability and clonal persistence are important concepts in molecular epidemiology as they facilitate the search for the source of sporadic cases or outbreaks of legionellosis. We studied the genotypic variability and persistence of Legionella pulsed-field gel electrophoresis (PFGE) patterns over time (period > 6 months) in 34 positive cooling towers from two different areas. In area A, radius of 70 km, 52 indistinguishable PFGE patterns were differentiated among the 27 cooling towers. In 13 cooling towers we observed >or= 2 PFGE patterns. Each cooling tower had its own indistinguishable Legionella PFGE pattern which was not shared with any other cooling tower. In area B, radius of 1 km, 10 indistinguishable PFGE patterns were obtained from the seven cooling towers. In four, we observed >or= 2 PFGE patterns. Three of these 10 indistinguishable PFGE patterns were shared by more than one cooling tower. In 27 of 34 cooling towers the same PFGE pattern was recovered after 6 months to up to 5 years of follow-up. The large genotypic diversity of Legionella observed in the cooling towers aids in the investigation of community outbreaks of Legionnaires' disease. However, shared patterns in small areas may confound the epidemiological investigation. The persistence of some PFGE patterns in cooling towers makes the recovery of the Legionella isolate causing the outbreak possible over time.
Completion of the Edward Air Force Base Statistical Guidance Wind Tool
NASA Technical Reports Server (NTRS)
Dreher, Joseph G.
2008-01-01
The goal of this task was to develop a GUI using EAFB wind tower data similar to the KSC SLF peak wind tool that is already in operations at SMG. In 2004, MSFC personnel began work to replicate the KSC SLF tool using several wind towers at EAFB. They completed the analysis and QC of the data, but due to higher priority work did not start development of the GUI. MSFC personnel calculated wind climatologies and probabilities of 10-minute peak wind occurrence based on the 2-minute average wind speed for several EAFB wind towers. Once the data were QC'ed and analyzed the climatologies were calculated following the methodology outlined in Lambert (2003). The climatologies were calculated for each tower and month, and then were stratified by hour, direction (10" sectors), and direction (45" sectors)/hour. For all climatologies, MSFC calculated the mean, standard deviation and observation counts of the Zminute average and 10-minute peak wind speeds. MSFC personnel also calculated empirical and modeled probabilities of meeting or exceeding specific 10- minute peak wind speeds using PDFs. The empirical PDFs were asymmetrical and bounded on the left by the 2- minute average wind speed. They calculated the parametric PDFs by fitting the GEV distribution to the empirical distributions. Parametric PDFs were calculated in order to smooth and interpolate over variations in the observed values due to possible under-sampling of certain peak winds and to estimate probabilities associated with average winds outside the observed range. MSFC calculated the individual probabilities of meeting or exceeding specific 10- minute peak wind speeds by integrating the area under each curve. The probabilities assist SMG forecasters in assessing the shuttle FR for various Zminute average wind speeds. The A M ' obtained the processed EAFB data from Dr. Lee Bums of MSFC and reformatted them for input to Excel PivotTables, which allow users to display different values with point-click-drag techniques. The GUI was created from the PivotTables using VBA code. It is run through a macro within Excel and allows forecasters to quickly display and interpret peak wind climatology and probabilities in a fast-paced operational environment. The GUI was designed to look and operate exactly the same as the KSC SLF tool since SMG forecasters were already familiar with that product. SMG feedback was continually incorporated into the GUI ensuring the end product met their needs. The final version of the GUI along with all climatologies, PDFs, and probabilities has been delivered to SMG and will be put into operational use.
NASA Technical Reports Server (NTRS)
Orcutt, John M.; Brenton, James C.
2016-01-01
The methodology and the results of the quality control (QC) process of the meteorological data from the Lightning Protection System (LPS) towers located at Kennedy Space Center (KSC) launch complex 39B (LC-39B) are documented in this paper. Meteorological data are used to design a launch vehicle, determine operational constraints, and to apply defined constraints on day-of-launch (DOL). In order to properly accomplish these tasks, a representative climatological database of meteorological records is needed because the database needs to represent the climate the vehicle will encounter. Numerous meteorological measurement towers exist at KSC; however, the engineering tasks need measurements at specific heights, some of which can only be provided by a few towers. Other than the LPS towers, Tower 313 is the only tower that provides observations up to 150 m. This tower is located approximately 3.5 km from LC-39B. In addition, data need to be QC'ed to remove erroneous reports that could pollute the results of an engineering analysis, mislead the development of operational constraints, or provide a false image of the atmosphere at the tower's location.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-22
... INTERNATIONAL TRADE COMMISSION [Investigation Nos. 701-TA-486 and 731-TA-1195-1196 (Final... Antidumping Investigations AGENCY: United States International Trade Commission. ACTION: Notice. SUMMARY: The...: Nathanael Comly (202-205-3174), Office of Investigations, U.S. International Trade Commission, 500 E Street...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-28
... traditional steam turbine generators. The Project would contain the central receiver or tower, a solar field... the Final Environmental Impact Statement for the Quartzsite Solar Energy Project and the Yuma Field...: Notice of Availability. SUMMARY: Quartzsite Solar Energy (QSE) has requested to interconnect the...
PNNL streamlines energy-guzzling computers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beckman, Mary T.; Marquez, Andres
In a room the size of a garage, two rows of six-foot-tall racks holding supercomputer hard drives sit back-to-back. Thin tubes and wires snake off the hard drives, slithering into the corners. Stepping between the rows, a rush of heat whips around you -- the air from fans blowing off processing heat. But walk farther in, between the next racks of hard drives, and the temperature drops noticeably. These drives are being cooled by a non-conducting liquid that runs right over the hardworking processors. The liquid carries the heat away in tubes, saving the air a few degrees. This ismore » the Energy Smart Data Center at Pacific Northwest National Laboratory. The bigger, faster, and meatier supercomputers get, the more energy they consume. PNNL's Andres Marquez has developed this test bed to learn how to train the behemoths in energy efficiency. The work will help supercomputers perform better as well. Processors have to keep cool or suffer from "thermal throttling," says Marquez. "That's the performance threshold where the computer is too hot to run well. That threshold is an industry secret." The center at EMSL, DOE's national scientific user facility at PNNL, harbors several ways of experimenting with energy usage. For example, the room's air conditioning is isolated from the rest of EMSL -- pipes running beneath the floor carry temperature-controlled water through heat exchangers to cooling towers outside. "We can test whether it's more energy efficient to cool directly on the processing chips or out in the water tower," says Marquez. The hard drives feed energy and temperature data to a network server running specially designed software that controls and monitors the data center. To test the center’s limits, the team runs the processors flat out – not only on carefully controlled test programs in the Energy Smart computers, but also on real world software from other EMSL research, such as regional weather forecasting models. Marquez's group is also developing "power aware computing", where the computer programs themselves perform calculations more energy efficiently. Maybe once computers get smart about energy, they'll have tips for their users.« less
Brixey, Laurie A; Heist, David K; Richmond-Bryant, Jennifer; Bowker, George E; Perry, Steven G; Wiener, Russell W
2009-12-01
This article is the second in a two-paper series presenting results from wind tunnel and computational fluid dynamics (CFD) simulations of flow and dispersion in an idealized model urban neighborhood. Pollutant dispersion results are presented and discussed for a model neighborhood that was characterized by regular city blocks of three-story row houses with a single 12-story tower located at the downwind edge of one of these blocks. The tower had three significant effects on pollutant dispersion in the surrounding street canyons: drawing the plume laterally towards the tower, greatly enhancing the vertical dispersion of the plume in the wake of the tower, and significantly decreasing the residence time of pollutants in the wake of the tower. In the wind tunnel, tracer gas released in the avenue lee of the tower, but several blocks away laterally, was pulled towards the tower and lifted in the wake of the tower. The same lateral movement of the pollutant was seen in the next avenue, which was approximately 2.5 tower heights downwind of the tower. The tower also served to ventilate the street canyon directly in its wake more rapidly than the surrounding areas. This was evidenced by CFD simulations of concentration decay where the residence time of pollutants lee of the 12-story tower was found to be less than half the residence time behind a neighboring three-story building. This same phenomenon of rapid vertical dispersion lee of a tower among an array of smaller buildings was also demonstrated in a separate set of wind tunnel experiments using an array of cubical blocks. A similar decrease in the residence time was observed when the height of one block was increased.
Alkaline approach to treating cooling towers for control of Legionella pneumophila
DOE Office of Scientific and Technical Information (OSTI.GOV)
States, S.J.; Conley, L.F.; Towner, S.G.
1987-08-01
Earlier field and laboratory studies have shown that Legionella species survive and multiply in the pH range 5.5 to 9.2. Additionally, the technical feasibility of operating cooling towers at elevated alkalinities and pH has previously been documented by published guidelines. The guidelines indicate that these conditions facilitate corrosion control and favor chlorine persistence which enhances the effectiveness of continuous chlorination in biofouling control. This information suggest that control of Legionella species in cooling towers can be accomplished by operating the towers under alkaline conditions. To test this possibility, we collected water samples over a period of months from a hospitalmore » cooling tower. The samples were analyzed for a variety of chemical parameters. Subsamples were pasteurized and inoculated with non-agar-passaged Legionella pneumophila which had been maintained in tap water. Correlation of subsequent Legionella growth with corresponding pH and alkalinity values revealed statistically significant inverse associations. These data support the hypothesis that operating cooling towers outside of the optimal conditions for Legionella growth (e.g., at elevated alkalinities and a pH greater than 9) may be a useful approach to controlling growth in this habitat.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arends, J.; Sandusky, William F.
2010-03-31
This report represents findings of a design review team that evaluated construction documents (at the 70% level) and operating specifications for a new control tower and support building that will be built in Las Vegas, Nevada by the Federal Aviation Administration (FAA). The focus of the review was to identify measures that could be incorporated into the final design and operating specification that would result in additional energy savings for the FAA that would not have otherwise occurred.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arends, J.; Sandusky, William F.
2010-03-01
This report represents findings of a design review team that evaluated construction documents (at the 70% level) and operating specifications for a new control tower and support building that will be build at Oakland, California by the Federal Aviation Administration (FAA). The focus of the review was to identify measures that could be incorporated into the final design and operating specification that would result in additional energy savings for the FAA that would not have otherwise occurred.
Research of metal solidification in zero-g state. [test apparatus and instrumentation
NASA Technical Reports Server (NTRS)
Aubin, W. M.; Larson, D., Jr.; Geschwind, G. I.
1973-01-01
An experiment test apparatus that allows metal melting and resolidification in the three seconds available during free fall in a drop tower was built and tested in the tower. Droplets (approximately 0.05 cm) of pure nickel and 1090 steel were prepared in this fashion. The apparatus, including instrumentation, is described. As part of the instrumentation, a method for measuring temperature-time histories of the free floating metal droplets was developed. Finally, a metallurgical analysis of the specimens prepared in the apparatus is presented.
2012-03-01
4 Body ...Final Report requirement. 5 Body The approved Statement of Work proposed the following timeline (Table 1): Table 1. Timeline for...prosthesis designs (Figure 1) were tested for this project including the 1E90 Sprinter (OttoBock Inc.), Flex-Run (Ossur), Cheetah ® (Ossur) and Nitro
Reusable Material for Drop Tower
2011-08-01
R3 Buna-N Rubber ............................................................................................... 32 B-3. R5 EPDM Rubber ...Butyl Rubber . Figure B-2. R3 Buna-N Rubber . Figure B-3. R5 EPDM Rubber . Figure B-4. R6 Gel Rubber . UNCLASSIFIED 33...11 Current Drop Tower Material & Setup .......................................................... 11 Bowling Ball Rubber Material Sample Test
NASA Technical Reports Server (NTRS)
Becker, Jeffrey C.
1995-01-01
The Thinking Machines CM-5 platform was designed to run single program, multiple data (SPMD) applications, i.e., to run a single binary across all nodes of a partition, with each node possibly operating on different data. Certain classes of applications, such as multi-disciplinary computational fluid dynamics codes, are facilitated by the ability to have subsets of the partition nodes running different binaries. In order to extend the CM-5 system software to permit such applications, a multi-program loader was developed. This system is based on the dld loader which was originally developed for workstations. This paper provides a high level description of dld, and describes how it was ported to the CM-5 to provide support for multi-binary applications. Finally, it elaborates how the loader has been used to implement the CM-5 version of MPIRUN, a portable facility for running multi-disciplinary/multi-zonal MPI (Message-Passing Interface Standard) codes.
Ruiz, J; Kaiser, A S; Lucas, M
2017-11-01
Cooling tower emissions have become an increasingly common hazard to the environment (air polluting, ice formation and salts deposition) and to the health (Legionella disease) in the last decades. Several environmental policies have emerged in recent years limiting cooling tower emissions but they have not prevented an increasing intensity of outbreaks. Since the level of emissions depends mainly on cooling tower component design and the operating conditions, this paper deals with an experimental investigation of the amount of emissions, drift and PM 10 , emitted by a cooling tower with different configurations (drift eliminators and distribution systems) and working under several operating conditions. This objective is met by the measurement of cooling tower source emission parameters by means of the sensitive paper technique. Secondary objectives were to contextualize the observed emission rates according to international regulations. Our measurements showed that the drift rates included in the relevant international standards are significantly higher than the obtained results (an average of 100 times higher) and hence, the environmental problems may occur. Therefore, a revision of the standards is recommended with the aim of reducing the environmental and human health impact. By changing the operating conditions and the distribution system, emissions can be reduced by 52.03% and 82% on average. In the case of drift eliminators, the difference ranges from 18.18% to 98.43% on average. As the emissions level is clearly influenced by operating conditions and components, regulation tests should be referred to default conditions. Finally, guidelines to perform emission tests and a selection criterion of components and conditions for the tested cooling tower are proposed. Copyright © 2017 Elsevier Ltd. All rights reserved.
Flame-Vortex Interactions Imaged in Microgravity - To Assess the Theory Flame Stretch
NASA Technical Reports Server (NTRS)
Driscoll, James F.
2001-01-01
The goals of this research are to: 1) Assess the Theory of Flame Stretch by operating a unique flame-vortex experiment under microgravity conditions in the NASA Glenn 2.2 Second Drop Tower (drops to identify operating conditions have been completed); 2) Obtain high speed shadowgraph images (500-1000 frames/s) using the drop rig (images were obtained at one-g, and the NASA Kodak RO camera is being mounted on the drop rig); 3) Obtain shadowgraph and PIV images at 1-g while varying the effects of buoyancy by controlling the Froude number (completed); 4) Numerically model the inwardly-propagating spherical flame that is observed in the experiment using full chemistry and the RUN 1DL code (completed); 5) Send images of the flame shape to Dr. G. Patniak at NRL who is numerically simulating the entire flame-vortex interaction of the present experiment (data transfer completed); and 6) Assess the feasibility of obtaining PIV velocity field images in the drop rig, which would be useful (but not required) for our assessment of the Theory of Flame Stretch (PIV images were obtained at one-g using same low laser power that is available from fiber optic cable in drop tower). The motivation for the work is to obtain novel measurement needed to develop a physically accurate model of turbulent combustion that can help in the control of engine pollutants. The unique experiment allows, for the first time, the detailed study of a negatively-curved (negatively stretched) flame, which is one of the five fundamental types of premixed flames. While there have been studies of flat flames, positively-curved (outwardly-propagating) cases and positively-strained (counterflow) cases, this is the first detailed study of a negatively-curved (inwardly-propagating) flame. The first set of drops in the 2.2 Second Drop Tower showed that microgravity provides more favorable conditions for achieving inwardly-propagating flames (IPFs) than 1-g. A vortex interacts with a flame and creates a spherical pocket, which burns inwardly. Shadowgraphs at 1000 frames/sec quantify the Markstein number and flame speed. A Low-Laser Power PIV System was developed and is being added to the drop package. Numerical computations were required to explain why the Markstein numbers measured for the inwardly-propagating flames differ from those of outward propagating flames; this is an important research issue in the assessment of the Theory of Flame Stretch. The RUN-1DL code (developed by Prof. B. Rogg) was run for IPF and OPFs with complex methane and propane chemistry. Results confirmed that Ma for the IPFs are larger than for OPFs as was observed experimentally. Physical reasons for these new findings about the Theory of Flame Stretch are being determined from the experiments and the computations. Several journal papers have been published; the drop package is described in the AIAA Journal, while the one-g results appear in three other journal papers.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-05
... on privately owned land, would contain the power block, a central receiver or tower, a solar field... Availability of the Final Environmental Impact Statement for the Rice Solar Energy, LLC Rice Solar Energy... Desert Conservation Area (CDCA) Plan Amendment for the Rice Solar Energy Project (RSEP) in Riverside...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-26
... Comment 19: Value Added Tax and Import Duties in the HRS Benchmark Used to Calculate CS Wind's Benefit...: Preliminary Determination of Sales at Less Than Fair Value and Postponement of Final Determination, 77 FR... of HRS Benchmark Provision of Electricity for LTAR Comment 16: Electricity Benchmarks Tax Programs...
East Coast Air Combat Maneuvering Range (EC/ACMR) Ocean Tower Construction Completion Report.
1978-03-01
c)D Sa con itionS.r n lectricaldes St rm oactlvtto ~Utost 311fa :... ea rjn d~ ,Rjon,&gj B. ADMIN a m . cu a C. OPERATIONS: O;erations at Tower F3 ...nections. D. EQUIP STATUS - NONE E. LOGISTICS - NONE F. TRAINING NONE C. SAFETY - NO ACCIDENTS H. t,.EDICAL- NO INJURIES 1. ,ORALE- Nigh ad Tower f3 ...74. .-- Y .~lile B-. driven 59 ftv/5 6 0, 060, and 040 haieers; AV B,"F - e driven 57 ft w/5 6 0 and 040 hammers; AV BPP 82 v/540. Total weather time
The Effects of a Duathlon Simulation on Ventilatory Threshold and Running Economy
Berry, Nathaniel T.; Wideman, Laurie; Shields, Edgar W.; Battaglini, Claudio L.
2016-01-01
Multisport events continue to grow in popularity among recreational, amateur, and professional athletes around the world. This study aimed to determine the compounding effects of the initial run and cycling legs of an International Triathlon Union (ITU) Duathlon simulation on maximal oxygen uptake (VO2max), ventilatory threshold (VT) and running economy (RE) within a thermoneutral, laboratory controlled setting. Seven highly trained multisport athletes completed three trials; Trial-1 consisted of a speed only VO2max treadmill protocol (SOVO2max) to determine VO2max, VT, and RE during a single-bout run; Trial-2 consisted of a 10 km run at 98% of VT followed by an incremental VO2max test on the cycle ergometer; Trial-3 consisted of a 10 km run and 30 km cycling bout at 98% of VT followed by a speed only treadmill test to determine the compounding effects of the initial legs of a duathlon on VO2max, VT, and RE. A repeated measures ANOVA was performed to determine differences between variables across trials. No difference in VO2max, VT (%VO2max), maximal HR, or maximal RPE was observed across trials. Oxygen consumption at VT was significantly lower during Trial-3 compared to Trial-1 (p = 0.01). This decrease was coupled with a significant reduction in running speed at VT (p = 0.015). A significant interaction between trial and running speed indicate that RE was significantly altered during Trial-3 compared to Trial-1 (p < 0.001). The first two legs of a laboratory based duathlon simulation negatively impact VT and RE. Our findings may provide a useful method to evaluate multisport athletes since a single-bout incremental treadmill test fails to reveal important alterations in physiological thresholds. Key points Decrease in relative oxygen uptake at VT (ml·kg-1·min-1) during the final leg of a duathlon simulation, compared to a single-bout maximal run. We observed a decrease in running speed at VT during the final leg of a duathlon simulation; resulting in an increase of more than 2 minutes to complete a 5 km run. During our study, highly trained athletes were unable to complete the final 5 km run at the same intensity that they completed the initial 10 km run (in a laboratory setting). A better understanding, and determination, of training loads during multisport training may help to better periodize training programs; additional research is required. PMID:27274661
5. Historic American Buildings Survey Photocopy of elevation drawing dated ...
5. Historic American Buildings Survey Photocopy of elevation drawing dated 1888 in office of First Coast Guard District, J. F. Kennedy Federal Building, Government Center, Boston, Mass. 02203 LIGHT-TOWER AT BOON ISLAND, MAINE SHOWING WROUGHT IRON WORK PROPOSED FOR ARRESTING VIBRATION OF LANTERN - Boon Island Light Tower, Cape Neddick, York County, ME
Carling, Christopher J.; Flanagan, Eamon; O’Doherty, Pearse; Piscione, Julien
2017-01-01
Purpose This study investigated exposure time, running and skill-related performance in two international u20 rugby union teams during an intensified tournament: the 2015 Junior World Rugby Championship. Method Both teams played 5 matches in 19 days. Analyses were conducted using global positioning system (GPS) tracking (Viper 2™, Statsports Technologies Ltd) and event coding (Opta Pro®). Results Of the 62 players monitored, 36 (57.1%) participated in 4 matches and 23 (36.5%) in all 5 matches while player availability for selection was 88%. Analyses of team running output (all players completing >60-min play) showed that the total and peak 5-minute high metabolic load distances covered were likely-to-very likely moderately higher in the final match compared to matches 1 and 2 in back and forward players. In individual players with the highest match-play exposure (participation in >75% of total competition playing time and >75-min in each of the final 3 matches), comparisons of performance in matches 4 and 5 versus match 3 (three most important matches) reported moderate-to-large decreases in total and high metabolic load distance in backs while similar magnitude reductions occurred in high-speed distance in forwards. In contrast, skill-related performance was unchanged, albeit with trivial and unclear changes, while there were no alterations in either total or high-speed running distance covered at the end of matches. Conclusions These findings suggest that despite high availability for selection, players were not over-exposed to match-play during an intensified u20 international tournament. They also imply that the teams coped with the running and skill-related demands. Similarly, individual players with the highest exposure to match-play were also able to maintain skill-related performance and end-match running output (despite an overall reduction in the latter). These results support the need for player rotation and monitoring of performance, recovery and intervention strategies during intensified tournaments. PMID:29136039
Carling, Christopher J; Lacome, Mathieu; Flanagan, Eamon; O'Doherty, Pearse; Piscione, Julien
2017-01-01
This study investigated exposure time, running and skill-related performance in two international u20 rugby union teams during an intensified tournament: the 2015 Junior World Rugby Championship. Both teams played 5 matches in 19 days. Analyses were conducted using global positioning system (GPS) tracking (Viper 2™, Statsports Technologies Ltd) and event coding (Opta Pro®). Of the 62 players monitored, 36 (57.1%) participated in 4 matches and 23 (36.5%) in all 5 matches while player availability for selection was 88%. Analyses of team running output (all players completing >60-min play) showed that the total and peak 5-minute high metabolic load distances covered were likely-to-very likely moderately higher in the final match compared to matches 1 and 2 in back and forward players. In individual players with the highest match-play exposure (participation in >75% of total competition playing time and >75-min in each of the final 3 matches), comparisons of performance in matches 4 and 5 versus match 3 (three most important matches) reported moderate-to-large decreases in total and high metabolic load distance in backs while similar magnitude reductions occurred in high-speed distance in forwards. In contrast, skill-related performance was unchanged, albeit with trivial and unclear changes, while there were no alterations in either total or high-speed running distance covered at the end of matches. These findings suggest that despite high availability for selection, players were not over-exposed to match-play during an intensified u20 international tournament. They also imply that the teams coped with the running and skill-related demands. Similarly, individual players with the highest exposure to match-play were also able to maintain skill-related performance and end-match running output (despite an overall reduction in the latter). These results support the need for player rotation and monitoring of performance, recovery and intervention strategies during intensified tournaments.
BOREAS TF-10 NSA-Fen Tower Flux and Meteorological Data
NASA Technical Reports Server (NTRS)
McCaughey, J. Harry; Hall, Forrest G. (Editor); Huemmrich, Karl (Editor); Jelinski, Dennis E.
2000-01-01
The BOREAS TF-10 team collected tower flux and meteorological data at two sites, a fen and a young jack pine forest, near Thompson, Manitoba, Canada, as part of BOREAS. A preliminary data set was assembled in August 1993 while field testing the instrument packages, and at both sites data were collected from 15-Aug to 31-Aug. The main experimental period was in 1994, when continuous data were collected from 08-Apr to 23-Sep at the fen site. A very limited experiment was run in the spring/ summer of 1995, when the fen site tower was operated from 08-Apr to 14-Jun in support of a hydrology experiment in an adjoining feeder basin. Upon examination of the 1994 data set, it became clear that the behavior of the heat, water, and carbon dioxide fluxes throughout the whole growing season was an important scientific question, and that the 1994 data record was not sufficiently long to capture the character of the seasonal behavior of the fluxes. Thus, the fen site was operated in 1996 in order to collect data from spring melt to autumn freeze-up. Data were collected from 29-Apr to 05-Nov at the fen site. All variables are presented as 30-minute averages. The data are stored in tabular ASCII files.
Distribution, Characteristics, and Biotic Availability of Fallout, Operation Plumbbob
1957-10-01
hours. Balloon mounted detonations produced fallout debris of higher water and acid solubility than did tower mounted detonations. The percentage of Sr89...of these radLoelements in fallout debris from balloon detonations than from tower detonations. The amounts of water- soluble Ba140 and Sr89, 90...99 5.3.1 Magnetic Properties ........................ 99 5.3.2 Solubility .............................. 100 5.3.2.1
Liftoff and Transition Aerodynamics of the Ares I (A106) Launch Vehicle
NASA Technical Reports Server (NTRS)
Capone, Francis J.; Paulson, John W., Jr.; Erickson, Gary E.
2011-01-01
An investigation has been conducted in the NASA Langley Research Center 14- by 22- Foot Subsonic Wind Tunnel to obtain the liftoff and transition aerodynamics of the Ares I (A106) Crew Launch Vehicle. Data were obtained in free-air at angles of attack from 10 to 90 at various roll angles and at roll angles of 0 to 360 at various angles of attack. In addition, tower effects were assessed by testing with and without a mobile launcher/tower at all wind azimuth angles and at various model heights to simulate the rise of the vehicle as it clears the tower on launch. The free-air data will be used for low speed high angle of attack flight simulation and as a bridge to the low angle of attack ascent database (0.5 < Mach < 5.0) being developed with data from the Langley Unitary Plan Wind Tunnel and Boeing Polysonic Wind Tunnel. The Ares I Database Development Team will add incremental tower effects data to the free-air data to develop the database for tower clearance.
1. Keeper's house, oil house, light tower and storage building, ...
1. Keeper's house, oil house, light tower and storage building, view northeast, south or southwest sides - Petit Manan Light Station, 2.5 miles south of Petit Manan Point, Milbridge, Washington County, ME
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koracin, D.; Kaplan, M.; Smith, C.
The main objectives of this project were to conduct a tall-tower and sodar field campaign in complex terrain, investigate wind properties relevant to wind energy assessment, and evaluate high-resolution models with fixed and adaptive grid structures. Two 60-m towers at Virginia Peak ridges near Washoe Valley, Nevada, were instrumented with cup and vane anemometers as well as sonic anemometers, and an acoustic sounder (hereafter sodar) was installed near one of the towers. The towers were located 2,700 m apart with a vertical distance of 140 m elevation between their bases. Each tower had a downhill exposure of rolling complex terrain,more » with the nearby valley floor 3,200 m to the west and 800 m below the summit. Cup anemometers were installed at both towers at 20, 40, and 60 m, wind vanes at 20 and 60 m, and sonic anemometers at 20 and 60 m. The sodar measurements were nominally provided every 10 m in vertical distance from 40 to 200 m with the quality of the data generally decreasing with height. Surface air temperature, atmospheric pressure, and radiation measurements were conducted at 1.5 m AGL at both of the towers. Although the plan was to conduct a 1-year period of data collection, we extended the period (October 5, 2012 through February 24, 2014) to cover for possible data loss from instrument or communication problems. We also present a preliminary analysis of the towers and sodar data, including a detailed inventory of available and missing data as well as outliers. The analysis additionally includes calculation of the Weibull parameters, turbulence intensity, and initial computation of wind power density at various heights.« less
NASA Astrophysics Data System (ADS)
King, Kristien C.
In order to further assess the wind energy potential for Nevada, the accuracy of a computational meteorological model, the Operational Multi-scale Environment model with Grid Adaptivity (OMEGA), was evaluated by comparing simulation results with data collected from a wind monitoring tower near Tonopah, NV. The state of Nevada is characterized by high mountains and low-lying valleys, therefore, in order to determine the wind potential for the state, meteorological models that predict the wind must be able to accurately represent and account for terrain features and simulate topographic forcing with accuracy. Topographic forcing has a dominant role in the development and modification of mesoscale flows in regions of complex terrain, like Tonopah, especially at the level of wind turbine blade heights (~80 m). Additionally, model factors such as horizontal resolution, terrain database resolution, model physics, time of model initialization, stability regime, and source of initial conditions may each affect the ability of a mesoscale model to forecast winds correctly. The observational tower used for comparison was located at Stone Cabin, Nevada. The tower had both sonic anemometers and cup anemometers installed at heights of 40 m, 60 m, and 80 m above the surface. During a previous experiment, tower data were collected for the period February 9 through March 10, 2007 and compared to model simulations using the MM5 and WRF models at a number of varying horizontal resolutions. In this previous research, neither the MM5 nor the WRF showed a significant improvement in ability to forecast wind speed with increasing horizontal grid resolution. The present research evaluated the ability of OMEGA to reproduce point winds as compared to the observational data from the Stone Cabin Tower at heights of 40 m, 60 m, and 80 m. Unlike other mesoscale atmospheric models, OMEGA incorporates an unstructured triangular adaptive grid which allows for increased flexibility and accuracy in characterizing areas of complex terrain. Model sensitivity to horizontal grid resolution, initial conditions, and time of initialization were tested. OMEGA was run over three different horizontal grid resolutions with minimum horizontal edge lengths of: 18 km, 6 km, and 2 km. For each resolution, the model was initialized using both the Global Forecasting System (GFS) and North American Regional Reanalysis (NARR) to determine model sensitivity to initial conditions. For both the NARR and GFS initializations, the model was started at both 0000 UTC and 1200 UTC to determine the effect of start time and stability regime on the performance of the model. An additional intensive study into the model's performance was also conducted by a detailed evaluation of model results during two separate 24-hour periods, the first a period where the model performed well and the second a period where the model performed poorly, to determine which atmospheric factors most affect the predictive ability of the OMEGA model. The statistical results were then compared with the results from the MM5 and WRF simulations to determine the most appropriate model for wind energy potential studies in complex terrain.
Convective Cloud Towers and Precipitation Initiation, Frequency and Intensity
NASA Astrophysics Data System (ADS)
Vant-hull, B.; Mahani, S. E.; Autones, F.; Rabin, R.; Mecikalski, J. R.; Khanbilvardi, R.
2012-12-01
: Geosynchronous satellite retrieval of precipitation is desirable because it would provide continuous observation throughout most of the globe in regions where radar data is not available. In the current work the distribution of precipitation rates is examined as a function of cloud tower area and cloud top temperature. A thunderstorm tracking algorithm developed at Meteo-France is used to track cumulus towers that are matched up with radar data at 5 minute 1 km resolution. It is found that roughly half of the precipitation occurs in the cloud mass that surrounds the towers, and when a tower is first detected the precipitation is already in progress 50% of the time. The average density of precipitation per area is greater as the towers become smaller and colder, yet the averaged shape of the precipitation intensity distribution is remarkably constant in all convective situations with cloud tops warmer than 220 K. This suggests that on average all convective precipitation events look the same, unaffected by the higher frequency of occurrence per area inside the convective towers. Only once the cloud tops are colder than 220 K does the precipitation intensity distribution become weighted towards higher instantaneous intensities. Radar precipitation shown in shades of green to blue, lightning in orange; black diamonds are coldest points in each tower. Ratio of number of pixels of given precipitation inside versus outside the convective towers, for various average cloud top temperatures. A flat plot indicates the distribution of rainfall inside and outside the towers has the same shape.
Chalk Point cooling tower project native vegetation study. Final report 1979
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patterson, G.W.; Galloway, R.A.; Francis, B.A.
1979-06-01
The Potomac Electric Power Company generating station at Chalk Point, MD, utilizes brackish water in its natural draft cooling tower and, consequently, releases saline aerosol into the atmosphere. A research and monitoring project was established in 1974 to evaluate the effects of this drift on native perennial vegetation. Leaf samples have been collected form dogwood, Cornys florida, Virginia pine, Pinus virginiana, black locust, Robinia pseudoacacia, and sassafras, Sassafras albidum, located at 12 different sites in the vicinity of the power plant. Sampling was begun prior to the operation of the cooling tower, 1974, and continued through 1978. Complete results frommore » monthly monitoring of foliar chloride in the four native tree species is documented for May through September 1978. Results from salt spray experiments indicate chloride and sodium concentrations in the wood of dogwood trees increases with increased spraying levels.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arends, J.; Sandusky, William F.
2010-06-30
Pacific Northwest National Laboratory (PNNL) and Redhorse Corporation (Redhorse) conducted an energy audit on the Federal Aviation Administration (FAA) control tower and base building in Reno, Nevada. This report presents the findings of the energy audit team that evaluated construction documents and operating specifications (at the 100% level) and completed a site visit. The focus of the review was to identify measures that could be incorporated into the final design and operating specifications that would result in additional energy savings for the FAA that would not have otherwise occurred.
CUORE-0 detector: design, construction and operation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alduino, C.; Alfonso, K.; Artusa, D. R.
The CUORE experiment will search for neutrinoless double-beta decay of 130Te with an array of 988 TeO 2 bolometers arranged in 19 towers. CUORE-0, the first tower assembled according to the CUORE procedures, was built and commissioned at Laboratori Nazionali del Gran Sasso, and took data from March 2013 to March 2015. In this study we describe the design, construction and operation of the CUORE-0 experiment, with an emphasis on the improvements made over a predecessor experiment, Cuoricino. Finally, in particular, we demonstrate with CUORE-0 data that the design goals of CUORE are within reach.
CUORE-0 detector: design, construction and operation
Alduino, C.; Alfonso, K.; Artusa, D. R.; ...
2016-07-12
The CUORE experiment will search for neutrinoless double-beta decay of 130Te with an array of 988 TeO 2 bolometers arranged in 19 towers. CUORE-0, the first tower assembled according to the CUORE procedures, was built and commissioned at Laboratori Nazionali del Gran Sasso, and took data from March 2013 to March 2015. In this study we describe the design, construction and operation of the CUORE-0 experiment, with an emphasis on the improvements made over a predecessor experiment, Cuoricino. Finally, in particular, we demonstrate with CUORE-0 data that the design goals of CUORE are within reach.
Effectiveness of bromicide against Legionella pneumophila in a cooling tower
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fliermans, C.B.; Harvey, R.S.
1983-01-01
Cooling towers are considered to be man-made amplifiers of Legionella. Thus the proper maintenance and choice of biocides is important. The only biocide that has thus far been shown to be effective in field tests is the judicious use of chlorination. Perturbation studies were conducted on an industrial cooling tower shown to contain Legionella, using 1-bromo-3-chloro-5,5-dimethylhydantoin (Bromicide, Great Lakes Chemical Corp.). At the manufacturer's recommended concentrations neither the density nor the activity of Legionella was affected. At concentrations greater than 2.0 ppM free residual, the Bromicide was not effective in reducing Legionella to source water concentrations, nor was it effectivemore » in reducing the INT activity of the bacterium in situ. The data indicate that at concentrations up to 2.0 ppM, Bromicide is not effective in these tower studies. 23 references, 3 tables.« less
Version 4 IMERG: Investigating Runs and High Latitudes
NASA Astrophysics Data System (ADS)
Huffman, G. J.; Bolvin, D. T.; Braithwaite, D.; Hsu, K. L.; Joyce, R.; Kidd, C.; Nelkin, E. J.; Sorooshian, S.; Tan, J.; Xie, P.
2016-12-01
The Integrated Multi-satellitE Retrievals for GPM (IMERG) merged precipitation product is being computed by the U.S. Global Precipitation Measurement mission (GPM) science team, based on intercalibrated estimates from the international constellation of precipitation-relevant satellites and other data. Recently, GPM upgraded the precipitation retrieval algorithms applied to individual sensors, and following that, IMERG was upgraded to Version 4. These data sets are computed at the half hour, 0.1° x 0.1° resolution over the latitude belt 60°N-S. Various latency requirements for different users are accommodated by computing IMERG in three "Runs" - Early, Late, and Final (5 hours, 15 hours, and 2.5 months after observation time, respectively). The near-real-time Early and Late Runs and the research-quality Final Run incorporate increasing amounts of data; examples will highlight the contribution that additional data make for each Run. From Early to Late, the addition of backward propagated data in the Late allows temporally weighted interpolation of forward and backward propagated precipitation, rather than the forward-only extrapolation in the Early. From Late to Final, the major addition is the direct use of monthly precipitation gauge analysis (the Global Precipitation Climatology Centre's Monitoring Analysis), which mitigates the satellite biases over land for the Early and Late. In addition, the new capabilities of the input algorithms at higher latitudes will be discussed, both during the snow season and the summer rain season. These inputs have a dominant role in determining the utility of IMERG in all seasons. Rainfall over non-frozen surface is reasonably well represented, while precipitation over frozen surfaces is still a topic of active research.
Simulation of Pressure-swing Distillation for Separation of Ethyl Acetate-Ethanol-Water
NASA Astrophysics Data System (ADS)
Yang, Jing; Zhou, Menglin; Wang, Yujie; Zhang, Xi; Wu, Gang
2017-12-01
In the light of the azeotrope of ethyl acetate-ethanol-water, a process of pressure-swing distillation is proposed. The separation process is simulated by Aspen Plus, and the effects of theoretical stage number, reflux ratio and feed stage about the pressure-swing distillation are optimized. Some better process parameters are as follows: for ethyl acetate refining tower, the pressure is 500.0 kPa, theoretical stage number is 16, reflux ratio is 0.6, feed stage is 5; for crude ethanol tower, the pressure is 101.3 kPa, theoretical stage number is 15, reflux ratio is 0.3, feed stage is 4; for ethanol tower, the pressure is 101.3 kPa, theoretical stage number is 25, reflux ratio is 1.2, feed stage is 10. The mass fraction of ethyl acetate in the bottom of the ethyl acetate refining tower reaches 0.9990, the mass fraction of ethanol in the top of the ethanol tower tower reaches 0.9017, the mass fraction of water in the bottom of the ethanol tower tower reaches 0.9622, and there is also no ethyl acetate in the bottom of the ethanol tower. With laboratory tests, experimental results are in good agreement with the simulation results, which indicates that the separation of ethyl acetate ethanol water can be realized by the pressure-swing distillation separation process. Moreover, it has certain practical significance to industrial practice.
Project Mercury Escape Tower Rockets Tests
1960-04-21
A Mercury capsule is mounted inside the Altitude Wind Tunnel for a test of its escape tower rockets at the National Aeronautics and Space Administration (NASA) Lewis Research Center. In October 1959 NASA’s Space Task Group allocated several Project Mercury assignments to Lewis. The Altitude Wind Tunnel was quickly modified so that its 51-foot diameter western leg could be used as a test chamber. The final round of tests in the Altitude Wind Tunnel sought to determine if the smoke plume from the capsule’s escape tower rockets would shroud or compromise the spacecraft. The escape tower, a 10-foot steel rig with three small rockets, was attached to the nose of the Mercury capsule. It could be used to jettison the astronaut and capsule to safety in the event of a launch vehicle malfunction on the pad or at any point prior to separation from the booster. Once actuated, the escape rockets would fire, and the capsule would be ejected away from the booster. After the capsule reached its apex of about 2,500 feet, the tower, heatshield, retropackage, and antenna would be ejected and a drogue parachute would be released. Flight tests of the escape system were performed at Wallops Island as part of the series of Little Joe launches. Although the escape rockets fired prematurely on Little Joe’s first attempt in August 1959, the January 1960 follow-up was successful.
Aerodynamic and engineering design of a 1.5 s high quality microgravity drop tower facility
NASA Astrophysics Data System (ADS)
Belser, Valentin; Breuninger, Jakob; Reilly, Matthew; Laufer, René; Dropmann, Michael; Herdrich, Georg; Hyde, Truell; Röser, Hans-Peter; Fasoulas, Stefanos
2016-12-01
Microgravity experiments are essential for research in space science, biology, fluid mechanics, combustion, and material sciences. One way to conduct microgravity experiments on Earth is by using drop tower facilities. These facilities combine a high quality of microgravity, adequate payload masses and have the advantage of virtually unlimited repeatability under same experimental conditions, at a low cost. In a collaboration between the Institute of Space Systems (IRS) at the University of Stuttgart and Baylor University (BU) in Waco, Texas, a new drop tower is currently under development at the Center for Astrophysics, Space Physics and Engineering Research (CASPER). The design parameters of the drop tower ask for at least 1.5 s in free fall duration while providing a quality of at least 10-5 g. Previously, this quality has only been achieved in vacuum drop tower facilities where the capsule experiences virtually zero aerodynamic drag during its free fall. Since this design comes at high costs, a different drop tower design concept, which does not require an evacuated drop shaft, was chosen. It features a dual-capsule system in which the experiment capsule is shielded from aerodynamic forces by surrounding it with a drag shield during the drop. As no other dual-capsule drop tower has been able to achieve a quality as good as or better than 10-5 g previous work optimized the design with an aerodynamic perspective by using computational fluid dynamics (CFD) simulations to determine the ideal shape and size of the outer capsule and to specify the aerodynamically crucial dimensions for the overall system. Experiments later demonstrated that the required quality of microgravity can be met with the proposed design. The main focus of this paper is the mechanical realization of the capsule as well as the development and layout of the surrounding components, such as the release mechanism, the deceleration device and the drop shaft. Because the drop tower facility is a complex system with many interdependencies between all of the components, several engineering challenges had to be addressed. For example, initial disturbances that are caused by the release mechanism are a common issue that arises at drop tower facilities. These vibrations may decrease the quality of microgravity during the initial segment of free fall. Because this would reduce the free fall time experiencing high quality microgravity, a mechanism has been developed to provide a soft release. Challenges and proposed solutions for all components are highlighted in this paper.
Site 300 Bat Monitoring Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Drennan, Joe; Tortosa, Justin
2016-07-18
From June 15 to 18, 2015, GANDA biologist Graham Neale assisted in programming and fieldtesting of the bat monitoring equipment. The equipment was deployed in the field on a meteorological (MET) tower within Site 300 on June 18, 2015.
Applied Meteorology Unit (AMU) Quarterly Report
NASA Technical Reports Server (NTRS)
Bauman, William; Crawford, Winifred; Watson, Leela; Wheeler, Mark
2011-01-01
This Quarter's Highlights include reports on the following tasks: (1) Mr. Wheeler completed a study for the 30th Weather Squadron at Vandenberg Air Force Base in California in which he found precursors in weather observations that will help the forecasters determine when they will get strong wind gusts at their northern towers. The final report is now on the AMU website at http://science.ksc.nasa.gov/amu/final-reports/30ws-north-base-winds.pdf. (2) continued work on the second phase of verifying the performance of the MesoNAM weather model at Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS). (3) continued work to improve the AMU peak wind tool by analyzing wind tower data to determine peak wind behavior during times of onshore and offshore flow. (4) continued updating lightning c1imatologies for KSC/CCAFS and other airfields around central Florida and created new c1imatologies for moisture and stability thresholds.
1998-12-07
S88-E-5055 (12-07-98) --- Astronaut James H. Newman is seen at a pressurized mating adapter during early moments of the first of three scheduled spacewalks on STS-88. Astronauts Newman and Jerry L. Ross, both mission specialists, went on to mate 40 cables and connectors running 76 feet from the Zarya control module to Unity, with the 35-ton complex towering over Endeavour;'s cargo bay. This photo was taken with an electronic still camera (ESC) at 23:26:22 GMT, Dec. 7.
Meteorological annual report for 1995 at the Savannah River Site
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hunter, C.H.; Tatum, C.P.
1996-12-01
The Environmental Technology Section (ETS) of the Savannah River Technology Center (SRTC) collects, archives, and analyzes basic meteorological data supporting a variety of activities at SRS. These activities include the design, construction, and operation of nuclear and non-nuclear facilities, emergency response, environmental compliance, resource management, and environmental research. This report contains tabular and graphical summaries of data collected during 1995 for temperature, precipitation, relative humidity, wind, barometric pressure, and solar radiation. Most of these data were collected at the central Climatology Facility. Summaries of temperature and relative humidity were generated with data from the lowest level of measurement at themore » Central Climatology Site tower (13 feet above ground). (Relative humidity is calculated from measurements of dew-point temperature.) Wind speed summaries were generated with data from the second measurement level (58 feet above ground). Wind speed measurements from this level are believed to best represent open, well-exposed areas of the Site. Precipitation summaries were based on data from the Building 773-A site since quality control algorithms for the central Climatology Facility rain gauge data were not finalized at the time this report was prepared. This report also contains seasonal and annual summaries of joint occurrence frequencies for selected wind speed categories by 22.5 degree wind direction sector (i.e., wind roses). Wind rose summaries are provided for the 200-foot level of the Central Climatology tower and for each of the eight 200-foot area towers.« less
An experimental study of windturbine noise from blade-tower wake interaction
NASA Astrophysics Data System (ADS)
Marcus, E. N.; Harris, W. L.
1983-04-01
A program of experiments has been conducted to study the impulsive noise of a horizontal axis windturbine. These tests were performed on a 1/53 scale model of the DOE-NASA MOD-1 windturbine. Experiments were performed in the M.I.T. 5 x 7-1/2 ft Anechoic Windtunnel Facility. The impulsive noise of a horizontal axis windturbine is observed to result from repeated blade passage through the mean velocity deficit induced in the lee of the windturbine support tower. The two factors which most influence this noise are rotation speed and tower drag coefficient. The intensity of noise from blade tower wake interaction is predicted to increase with the fourth power of the RPM and the second power of the tower drag coefficient. These predictions are confirmed in experiments. Further experiments are also presented in order to observe directionality of the acoustic field as well as the acoustic influence of tower shape and blade number.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hutchinson, Ken
2003-02-10
Vegetation Management for the Hanford-Ostrander Transmission Line Corridor from Tower 10/4 to Tower 17/2 + 770. The line is a 500kV Single Circuit Transmission Line having an easement width of 300 feet. The proposed work will be accomplished in the indicated sections of the transmission line corridor as referenced on the attached checklist. The work will include the performance of road maintenance and tower pad maintenance along the Hanford-Ostrander transmission line. Maintenance will be performed from Tower 10/1, close to Army Loop road near the northeast corner of 200 West Area of the Hanford Nuclear Reservation to the western edgemore » of the Arid Lands Ecological Reserve (ALE) at Tower 17/2 + 700. Total distance of the work is approximately 7.5 miles. The planned work includes spraying with herbicides to minimize vegetation regrowth along the access roads and removing shrubs from within 50 feet of each transmission tower.« less
NASA Astrophysics Data System (ADS)
Kang, Wonmo; Chen, YungChia; Bagchi, Amit; O'Shaughnessy, Thomas J.
2017-12-01
The material response of biologically relevant soft materials, e.g., extracellular matrix or cell cytoplasm, at high rate loading conditions is becoming increasingly important for emerging medical implications including the potential of cavitation-induced brain injury or cavitation created by medical devices, whether intentional or not. However, accurately probing soft samples remains challenging due to their delicate nature, which often excludes the use of conventional techniques requiring direct contact with a sample-loading frame. We present a drop-tower-based method, integrated with a unique sample holder and a series of effective springs and dampers, for testing soft samples with an emphasis on high-rate loading conditions. Our theoretical studies on the transient dynamics of the system show that well-controlled impacts between a movable mass and sample holder can be used as a means to rapidly load soft samples. For demonstrating the integrated system, we experimentally quantify the critical acceleration that corresponds to the onset of cavitation nucleation for pure water and 7.5% gelatin samples. This study reveals that 7.5% gelatin has a significantly higher, approximately double, critical acceleration as compared to pure water. Finally, we have also demonstrated a non-optical method of detecting cavitation in soft materials by correlating cavitation collapse with structural resonance of the sample container.
Credit WCT. Photographic copy of photograph, view looking northeast down ...
Credit WCT. Photographic copy of photograph, view looking northeast down onto new Dd test station from Test Stand "D" tower. Hatch of Dd test cell is open, and a test engine sits on a dolly nearby awaiting mounting. Note the water-cooled diffuser on the east end of the test chamber; this was soon replaced with a new diffuser and a steam-driven ejector for simulated high-altitude tests. A closed circuit television camera is mounted on the west end of the test cell. At the lower left of the view are fuel and oxidizer run tanks which supply propellants for test runs. (JPL negative no. 384-2650-A, 8 February 1961) - Jet Propulsion Laboratory Edwards Facility, Test Stand D, Edwards Air Force Base, Boron, Kern County, CA
NASA Astrophysics Data System (ADS)
Gan, Zhaoming; Li, Hui; Li, Shengtai; Yuan, Feng
2017-04-01
The distinctive morphology of head-tail radio galaxies reveals strong interactions between the radio jets and their intra-cluster environment, the general consensus on the morphology origin of head-tail sources is that radio jets are bent by violent intra-cluster weather. We demonstrate in this paper that such strong interactions provide a great opportunity to study the jet properties and also the dynamics of the intra-cluster medium (ICM). By three-dimensional magnetohydrodynamical simulations, we analyze the detailed bending process of a magnetically dominated jet, based on the magnetic tower jet model. We use stratified atmospheres modulated by wind/shock to mimic the violent intra-cluster weather. Core sloshing is found to be inevitable during the wind-cluster core interaction, which induces significant shear motion and could finally drive ICM turbulence around the jet, making it difficult for the jet to survive. We perform a detailed comparison between the behavior of pure hydrodynamical jets and the magnetic tower jet and find that the jet-lobe morphology could not survive against the violent disruption in all of our pure hydrodynamical jet models. On the other hand, the head-tail morphology is well reproduced by using a magnetic tower jet model bent by wind, in which hydrodynamical instabilities are naturally suppressed and the jet could always keep its integrity under the protection of its internal magnetic fields. Finally, we also check the possibility for jet bending by shock only. We find that shock could not bend the jet significantly, and thus could not be expected to explain the observed long tails in head-tail radio galaxies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gan, Zhaoming; Yuan, Feng; Li, Hui
The distinctive morphology of head–tail radio galaxies reveals strong interactions between the radio jets and their intra-cluster environment, the general consensus on the morphology origin of head–tail sources is that radio jets are bent by violent intra-cluster weather. We demonstrate in this paper that such strong interactions provide a great opportunity to study the jet properties and also the dynamics of the intra-cluster medium (ICM). By three-dimensional magnetohydrodynamical simulations, we analyze the detailed bending process of a magnetically dominated jet, based on the magnetic tower jet model. We use stratified atmospheres modulated by wind/shock to mimic the violent intra-cluster weather.more » Core sloshing is found to be inevitable during the wind-cluster core interaction, which induces significant shear motion and could finally drive ICM turbulence around the jet, making it difficult for the jet to survive. We perform a detailed comparison between the behavior of pure hydrodynamical jets and the magnetic tower jet and find that the jet-lobe morphology could not survive against the violent disruption in all of our pure hydrodynamical jet models. On the other hand, the head–tail morphology is well reproduced by using a magnetic tower jet model bent by wind, in which hydrodynamical instabilities are naturally suppressed and the jet could always keep its integrity under the protection of its internal magnetic fields. Finally, we also check the possibility for jet bending by shock only. We find that shock could not bend the jet significantly, and thus could not be expected to explain the observed long tails in head–tail radio galaxies.« less
Flow-driven Assembly of Microcapsule Towers
NASA Astrophysics Data System (ADS)
Shum, Henry; Balazs, Anna
2016-11-01
Large populations of the slime mold, Dictyostelium discoideum, are able to aggregate over a surface and collectively form a long, vertical stalk. Inspired by this biological behavior, we develop a synthetic mechanism for assembling tower-like structures using microcapsules as the building blocks. We accomplish this in simulations by generating a fluid flow field that draws microcapsules together along a surface and lifts them up at a central point. We considered a fluid flow generated by the local release of a chemical species from a patch on the surface. The concentration gradient of the diffusing chemical species causes radial diffusioosmotic flow along the solid surface toward the patch. Adhesive interactions keep the microcapsules attached to the surface as they are drawn together above the patch. To build a tower-like structure, some of the microcapsules must detach from the surface but remain attached to the rest of the cluster. The upward directed fluid flow above the patch then draws out the cluster into a tower shape. The final morphology of the aggregate structure depends on the flow field, the adhesive capsule-capsule and capsule-surface interaction strengths, and the sedimentation force on the capsules. Tuning these factors changes the structures that are produced.
2015-05-01
Infrastructure, Task 2.1” ERDC/CERL TR-15-5 ii Abstract Two critical infrastructure corrosion issues at Fort Bragg, NC, are the cor- rosion of steel utility...piping union joints in mechanical rooms and the cor- rosion of steel pump housings in cooling tower systems. Reliable operation of these components...pump 5 incorporating 316 stainless steel housing. .................................... 19 Figure 13. New pump 5 being installed
39. BOILER HOUSE, COAL CONVEYOR LEADING FROM COAL TOWER No. ...
39. BOILER HOUSE, COAL CONVEYOR LEADING FROM COAL TOWER No. 1 (WEST) (NOTE: COAL CARS No. 9 & 5 IN BACKGROUND) - Delaware County Electric Company, Chester Station, Delaware River at South end of Ward Street, Chester, Delaware County, PA
Match-to-match variability in high-speed running activity in a professional soccer team.
Carling, Christopher; Bradley, Paul; McCall, Alan; Dupont, Gregory
2016-12-01
This study investigated variability in competitive high-speed running performance in an elite soccer team. A semi-automated tracking system quantified running performance in 12 players over a season (median 17 matches per player, 207 observations). Variability [coefficient of variation (CV)] was compared for total sprint distance (TSD, >25.2 km/h), high-speed running (HSR, 19.8-25.2 km/h), total high-speed running (THSR, ≥19.8 km/h); THSR when the team was in and out of ball possession, in individual ball possession, in the peak 5 min activity period; and distance run according to individual maximal aerobic speed (MAS). Variability for % declines in THSR and distance covered at ≥80% MAS across halves, at the end of play (final 15 min vs. mean for all 15 min periods) and transiently (5 min period following peak 5 min activity period), was analysed. Collectively, variability was higher for TSD versus HSR and THSR and lowest for distance run at ≥80% MAS (CVs: 37.1%, 18.1%, 19.8% and 11.8%). THSR CVs when the team was in/out of ball possession, in individual ball possession and during the peak 5 min period were 31.5%, 26.1%, 60.1% and 23.9%. Variability in THSR declines across halves, at the end of play and transiently, ranged from 37.1% to 142.6%, while lower CVs were observed in these metrics for running at ≥80% MAS (20.9-53.3%).These results cast doubt on the appropriateness of general measures of high-speed activity for determining variability in an elite soccer team, although individualisation of HSR thresholds according to fitness characteristics might provide more stable indicators of running performance and fatigue occurrence.
Themis - A solar power station
NASA Astrophysics Data System (ADS)
Hillairet, J.
The organization, goals, equipment, costs, and performance of the French Themis (Thermo-helio-electric-MW) project are outlined. The program was begun for both the domestic energy market and for export. The installation comprises a molten eutectic salt loop which receives heat from radiators situated in a central tower. The salt transfers the heat to water for steam generation of electricity. A storage tank holds enough molten salt to supply one day's reserve of power, 40 MWh. A field of heliostats directs the suns rays for an estimated 2400 hr/yr onto the central receiver aperture, while 11 additional parabolic concentrators provide sufficient heat to keep the salt reservoir at temperatures exceeding 200 C. In a test run of several months during the spring of 1982 the heliostats directed the sun's rays with an average efficiency of 75 percent, yielding 2.3 MW of power at a system efficiency of 20.5 percent in completely automatic operation.
Prevalence of Legionella strains in cooling towers and legionellosis cases in New Zealand.
Lau, Robert; Maqsood, Saadia; Harte, David; Caughley, Brian; Deacon, Rob
2013-01-01
Over 3,900 water samples from 688 cooling towers were tested for Legionella in 2008 in New Zealand. Of 80 (2.05% isolation rate) Legionella isolates, 10 (12.5%) were L. pneumophila serogroup 1; 10 (12.5%) were L. anisa; nine (11.2%) were L. pneumophila serogroup 8; and one (1.2%) was L. longbeachae serogroup 2. Forty-one (51.2%) Legionella isolates were L. pneumophila serogroups. Over 3,990 water samples from 606 cooling towers were tested for Legionella in 2009 in New Zealand. Of 51 (1.28% isolation rate) Legionella isolates, 18 (35.3%) were L. pneumophila serogroup 1, and 39 (76.4%) were other L. pneumophila serogroups. L. pneumophila serogroups were significantly associated with legionellosis cases in 2008 and 2009. L. longbeachae serogroups were equally significantly associated with legionellosis cases. This significant association of L. longbeachae with legionellosis particularly of L. longbeachae serogroup 1 is unique in that part of the world. The authors' study also showed that the aqueous environment of the cooling tower is not a natural habitat for pathogenic L. longbeachae. Regular monitoring and maintenance of cooling towers have prevented outbreaks of legionellosis.
Spot and Runway Departure Advisor
NASA Technical Reports Server (NTRS)
Jung, Yoon Chul
2013-01-01
The Spot and Runway Departure Advisor (SARDA) is a research prototype of a decision support tool for ATC tower controllers to assist in manging and controlling traffic on the surface of an airport. SARDA employs a scheduler to generate an optimal runway schedule and gate push-back - spot release sequence and schedule that improves efficiency of surface operations. The advisories for ATC tower controllers are displayed on an Electronic Flight Strip (EFS) system. The human-in-the-loop simulation of the SARDA tool was conducted for east operations of Dallas-Ft. Worth International Airport (DFW) to evaluate performance of the SARDA tool and human factors, such as situational awareness and workload. The results indicates noticeable taxi delay reduction and fuel savings by using the SARDA tool. Reduction in controller workload were also observed throughout the scenario runs. The future plan includes modeling and simulation of the ramp operations of the Charlotte International Airport, and develop a decision support tool for the ramp controllers.
A Meso-Climatology Study of the High-Resolution Tower Network Over the Florida Spaceport
NASA Technical Reports Server (NTRS)
Case, Jonathan L.; Bauman, William H., III
2004-01-01
Forecasters at the US Air Force 45th Weather Squadron (45 WS) use wind and temperature data from the tower network over the Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS) to evaluate Launch Commit Criteria and to issue and verify temperature and wind advisories, watches, and warnings for ground operations. The Spaceflight Meteorology Group at the Johnson Space Center in Houston, TX also uses these data when issuing forecasts for shuttle landings at the KSC Shuttle Landing Facility. Systematic biases in these parameters at any of the towers could adversely affect an analysis, forecast, or verification for all of these operations. In addition, substantial geographical variations in temperature and wind speed can occur under specific wind directions. Therefore, the Applied Meteorology Unit (AMU), operated by ENSCO Inc., was tasked to develop a monthly and hourly climatology of temperatures and winds from the tower network, and identify the geographical variation, tower biases, and the magnitude of those biases. This paper presents a sub-set of results from a nine-year climatology of the KSC/CCAFS tower network, highlighting the geographical variations based on location, month, times of day, and specific wind direction regime. Section 2 provides a description of the tower mesonetwork and instrumentation characteristics. Section 3 presents the methodology used to construct the tower climatology including QC methods and data processing. The results of the tower climatology are presented in Section 4 and Section 5 summarizes the paper.
2013-03-01
Sequencing; and 5) Taxi Routing (with Conformance Monitoring). Third, the impact of these DSTs on tower cab operational activities, sub-activities...keystroke or interface level. Fourth, the impact of the DSTs on aptitudes required of controllers is evaluated. The importance of the following aptitudes...Analysis of Mid-Term NextGen Impact on Aptitudes Required in the ATCT Cab ---------------- 36 Mid-Term DST Impact on Tower Cab Controller Roles
Castellani Pastoris, M; Ciceroni, L; Lo Monaco, R; Goldoni, P; Mentore, B; Flego, G; Cattani, L; Ciarrocchi, S; Pinto, A; Visca, P
1997-12-01
Fatty acid profile analysis, monoclonal antibody (MAb) subtyping, pulsed-field gel electrophoresis (PFGE), arbitrarily primed polymerase chain reaction (AP-PCR), and ribotyping were used to compare clinical and environmental Legionella pneumophila serogroup 1 isolates from an outbreak of Legionnaires' disease presumptively associated with cooling towers. According to the Oxford subtyping scheme, the MAb subtype of patients' isolates and of two strains originating from a cooling tower was Pontiac, whereas the other isolates were subtype Olda. The strains showed no intrinsic strain-to-strain difference in fatty acid profiles, and ribotyping and length polymorphism of the 16S-23S rDNA intervening regions failed to reveal any differences between the isolates. Conversely, PFGE and AP-PCR appeared to be more discriminatory, as the same genomic profile was found for the clinical and some environmental strains. Meteorologic and epidemiological data and the results of molecular analysis of the Legionella pneumophila serogroup 1 isolates support the hypothesis that the infection was transmitted from one of the cooling towers to the indoor environment of the same building, to homes in proximity that had open windows, and to the streets. In fact, the outbreak diminished and later ended after a part in the tower was replaced. This investigation demonstrates the utility of combined molecular methods (i.e., phenotypic and genomic typing) in comparing epidemiologically linked clinical and environmental isolates. Finally, the outbreak confirms the risk of Legionnaires' disease posed by cooling towers, mainly when atmospheric thermal and humidity inversions occur. This finding emphasizes the need to determine whether the source of infection is in the living or working environment or somewhere else.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arends, J.; Sandusky, William F.
2010-06-28
This report documents an energy audit performed by Pacific Northwest National Laboratory (PNNL) and Redhorse Corporation (Redhorse) conducted on the Federal Aviation Administration (FAA) control tower and base building in Boise, Idaho. This report presents findings of the energy audit team that evaluated construction documents and operating specifications (at the 100% level) followed by a site visit of the facility under construction. The focus of the review was to identify measures that could be incorporated into the final design and operating specifications that would result in additional energy savings for FAA that would not have otherwise occurred.
Hexcrete Tower for Harvesting Wind Energy at Taller Hub Heights - Budget Period 2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sritharan, Sri
Interest in designing taller towers for wind energy production in the United States (U.S.) has been steadily growing. In May 2015, it was revealed that taller towers will make wind energy production a reality in all 50 states, including some states that have nearly zero renewables in their energy portfolio. Facilitating wind energy production feasibility in all 50 states will no doubt contribute to increasing the electricity produced by wind from 4.5% in 2013 to a targeted scenario of 35% by 2050 in the Wind Vision report. This project focuses on the Hexcrete tower concept developed for tall towers usingmore » High Strength Concrete (HSC) and/or Ultra-High Performance Concrete (UHPC). Among other benefits, the Hexcrete concept overcomes transportation and logistical challenges, thus facilitating construction of towers with hub heights of 100-m (328-ft) and higher. The goal of this project is to facilitate widespread deployment of Hexcrete towers for harvesting wind energy at 120 to 140-m (394 to 459-ft) hub heights and reduce the Levelized Cost of Energy (LCOE) of wind energy production in the U.S. The technical scope of the project includes detailed design and optimization of at least three wind turbine towers using the Hexcrete concept together with experimental validation and LCOE analyses and development of a commercialization plan.« less
Critical Velocity Is Associated With Combat-Specific Performance Measures in a Special Forces Unit.
Hoffman, Mattan W; Stout, Jeffrey R; Hoffman, Jay R; Landua, Geva; Fukuda, David H; Sharvit, Nurit; Moran, Daniel S; Carmon, Erez; Ostfeld, Ishay
2016-02-01
The purpose of this study was to examine the relationship between critical velocity (CV) and anaerobic distance capacity (ADC) to combat-specific tasks (CST) in a special forces (SFs) unit. Eighteen male soldiers (mean ± SD; age: 19.9 ± 0.8 years; height: 177.6 ± 6.6 cm; body mass: 74.1 ± 5.8 kg; body mass index [BMI]: 23.52 ± 1.63) from an SF unit of the Israel Defense Forces volunteered to complete a 3-minute all-out run along with CST (2.5-km run, 50-m casualty carry, and 30-m repeated sprints with "rush" shooting [RPTDS]). Estimates of CV and ADC from the 3-minute all-out run were determined from data downloaded from a global position system device worn by each soldier, with CV calculated as the average velocity of the final 30 seconds of the run and ADC as the velocity-time integral above CV. Critical velocity exhibited significant negative correlations with the 2.5-km run time (r = -0.62, p < 0.01) and RPTDS time (r = -0.71, p < 0.01). In addition, CV was positively correlated with the average velocity during the 2.5-km run (r = 0.64, p < 0.01). Stepwise regression identified CV as the most significant performance measure associated with the 2.5-km run time, whereas BMI and CV measures were significant predictors of RPTDS time (R(2) = 0.67, p ≤ 0.05). Using the 3-minute all-out run as a testing measurement in combat, personnel may offer a more efficient and simpler way in assessing both aerobic and anaerobic capabilities (CV and ADC) within a relatively large sample.
NASA Astrophysics Data System (ADS)
Xu, K.; Sühring, M.; Metzger, S.; Desai, A. R.
2017-12-01
Most eddy covariance (EC) flux towers suffer from footprint bias. This footprint not only varies rapidly in time, but is smaller than the resolution of most earth system models, leading to a systemic scale mismatch in model-data comparison. Previous studies have suggested this problem can be mitigated (1) with multiple towers, (2) by building a taller tower with a large flux footprint, and (3) by applying advanced scaling methods. Here we ask: (1) How many flux towers are needed to sufficiently sample the flux mean and variation across an Earth system model domain? (2) How tall is tall enough for a single tower to represent the Earth system model domain? (3) Can we reduce the requirements derived from the first two questions with advanced scaling methods? We test these questions with output from large eddy simulations (LES) and application of the environmental response function (ERF) upscaling method. PALM LES (Maronga et al. 2015) was set up over a domain of 12 km x 16 km x 1.8 km at 7 m spatial resolution and produced 5 hours of output at a time step of 0.3 s. The surface Bowen ratio alternated between 0.2 and 1 among a series of 3 km wide stripe-like surface patches, with horizontal wind perpendicular to the surface heterogeneity. A total of 384 virtual towers were arranged on a regular grid across the LES domain, recording EC observations at 18 vertical levels. We use increasing height of a virtual flux tower and increasing numbers of virtual flux towers in the domain to compute energy fluxes. Initial results show a large (>25) number of towers is needed sufficiently sample the mean domain energy flux. When the ERF upscaling method was applied to the virtual towers in the LES environment, we were able to map fluxes over the domain to within 20% precision with a significantly smaller number of towers. This was achieved by relating sub-hourly turbulent fluxes to meteorological forcings and surface properties. These results demonstrate how advanced scaling techniques can decrease the number of towers, and thus experimental expense, required for domain-scaling over heterogeneous surface.
1998-12-07
S88-E-5057 (12-07-98) --- Astronaut James H. Newman, waves at camera as he holds onto one of the hand rails on the Unity connecting module during the early stages of a 7-hour, 21-minute spacewalk. Astronauts Newman and Jerry L. Ross, both mission specialists, went on to mate 40 cables and connectors running 76 feet from the Zarya control module to Unity, with the 35-ton complex towering over Endeavour's cargo bay. This photo was taken with an electronic still camera (ESC) at 23:37:40 GMT, Dec. 7.
Astronaut Newman holds onto handrail 0133 on panel NOD1/C2-07
1998-12-07
S88-E-5056 (12-07-98) --- Astronaut James H. Newman, holds one of the hand rails on the Unity connecting module during the early stages of a 7-hour, 21-minute spacewalk. Astronauts Newman and Jerry L. Ross, both mission specialists, went on to mate 40 cables and connectors running 76 feet from the Zarya control module to Unity, with the 35-ton complex towering over Endeavour's cargo bay. This photo was taken with an electronic still camera (ESC) at 23:37:07 GMT, Dec. 7.
2017-11-02
NASA, Boeing and United Launch Alliance personnel run a water deluge test on the Crew Access Tower at Space Launch Complex 41 on Cape Canaveral Air Force Station in Florida. The test gathered data on how launch site and astronaut crews would exit in the event of an emergency from the white room at the end of the crew access arm to the emergency escape system on the pad. Boeing’s Starliner will launch on a United Launch Alliance Atlas V rocket to the International Space Station as part of NASA’s Commercial Crew Program.
A Fast and Self-Acting Release-Caging-Mechanism for Actively Driven Drop Tower Systems
NASA Astrophysics Data System (ADS)
Gierse, Andreas; Kaczmarczik, Ulrich; Greif, Andreas; Selig, Hanns; von Kampen, Peter; Könemann, Thorben; Lämmerzahl, Claus
2017-10-01
Today's and future scientific research programs ask for high quality microgravity conditions of 10-6 g on ground combined with high repetition rates of 100 flights per day or more. Accordingly, a new type of drop tower, the GraviTower Bremen, (GTB), has been suggested and is currently under development. As a first stage of development, a GTB-Prototype (GTB-Pro) has been designed which uses an active rope drive to accelerate a slider/drag shield and an experiment therein on a vertical parabola. During the free fall phase, the experiment is decoupled from the slider by a self-acting Release-Caging-Mechanism (RCM). Our prototype will provide 2.5 s of microgravity for experiments of up to 500 kg for at least 100 times per day. In this article, the final concept of the engineering of the active rope drive and the RCM are presented in detail. Based on extensive simulations aiming at an optimization of the whole system we developed a hydraulic rope drive system with minimized vibrational amplitude and low number of eigenfrequencies. The RCM achieves a very fast (≤ 0.1 s) self-acting release of the experiment from the slider by making use of the dynamics of the hydraulic rope drive. Furthermore, passive hydraulic stop dampers in the RCM build a passive and self-acting recoupling mechanism. This system is optimized for a fast decoupling to compensate for the time limitation posed by the chosen drive technology. The simulations included a comparison of different drive technologies, physical effects like the Coriolis force, and the dynamics of the RCM system itself.
Particulate matter emission by a vehicle running on unpaved road
NASA Astrophysics Data System (ADS)
Williams, David Scott; Shukla, Manoj K.; Ross, Jim
2008-05-01
The particulate matter (PM) emission from unpaved roads starts with the pulverization of surface material by the force of the vehicle, uplifting and subsequent exposure of road to strong air currents behind the wheels. The objectives of the project were to: demonstrate the utility of a simple technique for collecting suspended airborne PM emitted by vehicle running on an unpaved road, determine the mass balance of airborne PM at different heights, and determine the particle size and elemental composition of PM. We collected dust samples on sticky tapes using a rotorod sampler mounted on a tower across an unpaved road located at the Leyendecker Plant Sciences Research Center, Las Cruces, NM, USA. Dust samples were collected at 1.5, 4.5 and 6 m height above the ground surface on the east and west side of the road. One rotorod sampler was also installed at the centre of the road at 6 m height. Dust samples from unpaved road were mostly (70%) silt and clay-sized particles and were collected at all heights. The height and width of the PM plume and the amount of clay-sized particles captured on both sides of the road increased with speed and particle captured ranged from 0.05 to 159 μm. Dust particles between PM10 and PM2.5 did not correlate with vehicle speed but particles ⩽PM2.5 did. Emission factors estimated for the total suspended PM were 10147 g km-1 at 48 km h-1 and 11062 g km-1 at 64 km h-1 speed, respectively. The predominant elements detected in PM were carbon, aluminum and silica at all heights. Overall, sticky tape method coupled with electron microscopy was a useful technique for a rapid particle size and elemental characterization of airborne PM.
NASA/FAA North Texas Research Station Overview
NASA Technical Reports Server (NTRS)
Borchers, Paul F.
2012-01-01
NTX Research Staion: NASA research assets embedded in an interesting operational air transport environment. Seven personnel (2 civil servants, 5 contractors). ARTCC, TRACON, Towers, 3 air carrier AOCs(American, Eagle and Southwest), and 2 major airports all within 12 miles. Supports NASA Airspace Systems Program with research products at all levels (fundamental to system level). NTX Laboratory: 5000 sq ft purpose-built, dedicated, air traffic management research facility. Established data links to ARTCC, TRACON, Towers, air carriers, airport and NASA facilities. Re-configurable computer labs, dedicated radio tower, state-of-the-art equipment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tyndall, R.L.
1983-07-01
Air was sampled at the point of discharge and at short distances downwind and upwind from industrial and power-plant cooling towers. Both high-volume electrostatic and impinger type samplers were used. Concentrates of the air samples were analyzed for Legionnaires' Disease Bacteria (LDB). In some cases, the samples were also tested for the presence of free-living amoebae. The concentrations of LDB in the air samples were well below the minimal infectious dose for guinea pigs and precluded testing of the samples for infectious LDB. Results of LDB analysis were related to the meteorological conditions at the time of sampling. Generally, themore » concentrations of LDB in the air at the discharge of the cooling towers were 1 x 10/sup -6/ to 1 x 10/sup -7/ of that found in comparable volumes of tower basin water. During periods of high humidity and wind speed, LDB was detected in a few downwind samples and one upwind sample. One site with extensive construction and excavation activity had higher LDB concentrations in air samples relative to other sites. Nonpathogenic Naegleria were present in one of two air samples taken in the mist at the base of a natural-draft cooling tower.« less
Ishimatsu, S; Miyamoto, H; Hori, H; Tanaka, I; Yoshida, S
2001-08-01
Cooling tower water has frequently been cited as a source of infection in outbreaks of Legionnaires' disease. However, there have been few reports on the presence of legionellae in aerosols from cooling towers. This paper describes our use of an impinger or a six-stage microbial impactor for detecting legionellae in air around a cooling tower contaminated with L. pneumophila (1.2+/-0.3x10(5) CFU/100 ml). Phosphate-buffered saline, Page's saline, 2% yeast extract solution and buffered yeast extract (BYE) broth were tested to evaluate their collection efficiency. These solutions were compared in laboratory experiments using an aerosol of L. pneumophila serogroup (SG) 1. Because BYE broth was the most efficient and storable collecting fluid among them, it was used for outdoor air sampling. In the outdoor air sampling, aerosolized L. pneumophila SG 6 was detected in the air around the cooling tower by the impinger (0.09 CFU/l. air). No legionellae were detected by the impactor with Legionella-selective agar plates (WYOalpha) because the plates were overgrown with fungi. Repetitive element PCR (rep-PCR) and arbitrarily primed PCR (AP-PCR) were employed to assess the epidemiological relationship among Legionella isolates from the air sample and the cooling tower water samples. L. pneumophila SG 6 isolated from the aerosols produced rep-PCR and AP-PCR fingerprints identical to those of L. pneumophila SG 6 strains from the cooling tower water, suggesting that the bacterium was aerosolized from the cooling tower.
Hung-Pin, Lin
2014-01-01
The purpose of this paper is to investigate the short-run and long-run causality between renewable energy (RE) consumption and economic growth (EG) in nine OECD countries from the period between 1982 and 2011. To examine the linkage, this paper uses the autoregressive distributed lag (ARDL) bounds testing approach of cointegration test and vector error-correction models to test the causal relationship between variables. The co-integration and causal relationships are found in five countries-United States of America (USA), Japan, Germany, Italy, and United Kingdom (UK). The overall results indicate that (1) a short-run unidirectional causality runs from EG to RE in Italy and UK; (2) long-run unidirectional causalities run from RE to EG for Germany, Italy, and UK; (3) a long-run unidirectional causality runs from EG to RE in USA, and Japan; (4) both long-run and strong unidirectional causalities run from RE to EG for Germany and UK; and (5) Finally, both long-run and strong unidirectional causalities run from EG to RE in only USA. Further evidence reveals that policies for renewable energy conservation may have no impact on economic growth in France, Denmark, Portugal, and Spain.
Hung-Pin, Lin
2014-01-01
The purpose of this paper is to investigate the short-run and long-run causality between renewable energy (RE) consumption and economic growth (EG) in nine OECD countries from the period between 1982 and 2011. To examine the linkage, this paper uses the autoregressive distributed lag (ARDL) bounds testing approach of cointegration test and vector error-correction models to test the causal relationship between variables. The co-integration and causal relationships are found in five countries—United States of America (USA), Japan, Germany, Italy, and United Kingdom (UK). The overall results indicate that (1) a short-run unidirectional causality runs from EG to RE in Italy and UK; (2) long-run unidirectional causalities run from RE to EG for Germany, Italy, and UK; (3) a long-run unidirectional causality runs from EG to RE in USA, and Japan; (4) both long-run and strong unidirectional causalities run from RE to EG for Germany and UK; and (5) Finally, both long-run and strong unidirectional causalities run from EG to RE in only USA. Further evidence reveals that policies for renewable energy conservation may have no impact on economic growth in France, Denmark, Portugal, and Spain. PMID:24558343
Maciejczyk, Marcin; Więcek, M; Szymura, J; Szyguła, Z
2013-09-01
The purpose of this study was to compare the physiological and the acid-base balance response to running at various slope angles. Ten healthy men 22.3 ± 1.56 years old participated in the study. The study consisted of completing the graded test until exhaustion and three 45-minute runs. For the first 30 minutes, runs were performed with an intensity of approximately 50% VO2max, while in the final 15 minutes the slope angle of treadmill was adjusted (0°; +4.5°; -4.5°), and a fixed velocity of running was maintained. During concentric exercise, a significant increase in the levels of physiological indicators was reported; during eccentric exercise, a significant decrease in the level of the analyzed indicators was observed. Level running did not cause significant changes in the indicators of acid-base balance. The indicators of acid-base balance changed significantly in the case of concentric muscle work (in comparison to level running) and after the eccentric work, significant and beneficial changes were observed in most of the biochemical indicators. The downhill run can be used for a partial regeneration of the body during exercise, because during this kind of effort an improvement of running economy was observed, and this type of effort did not impair the acid-base balance of body.
NASA Technical Reports Server (NTRS)
Marchese, Anthony J.; Dryer, Frederick L.
1997-01-01
This program supports the engineering design, data analysis, and data interpretation requirements for the study of initially single component, spherically symmetric, isolated droplet combustion studies. Experimental emphasis is on the study of simple alcohols (methanol, ethanol) and alkanes (n-heptane, n-decane) as fuels with time dependent measurements of drop size, flame-stand-off, liquid-phase composition, and finally, extinction. Experiments have included bench-scale studies at Princeton, studies in the 2.2 and 5.18 drop towers at NASA-LeRC, and both the Fiber Supported Droplet Combustion (FSDC-1, FSDC-2) and the free Droplet Combustion Experiment (DCE) studies aboard the shuttle. Test matrix and data interpretation are performed through spherically-symmetric, time-dependent numerical computations which embody detailed sub-models for physical and chemical processes. The computed burning rate, flame stand-off, and extinction diameter are compared with the respective measurements for each individual experiment. In particular, the data from FSDC-1 and subsequent space-based experiments provide the opportunity to compare all three types of data simultaneously with the computed parameters. Recent numerical efforts are extending the computational tools to consider time dependent, axisymmetric 2-dimensional reactive flow situations.
Trigger readout electronics upgrade for the ATLAS Liquid Argon Calorimeters
NASA Astrophysics Data System (ADS)
Dinkespiler, B.
2017-09-01
The upgrade of the Large Hadron Collider (LHC) scheduled for the 2019-2020 shut-down period, referred to as Phase-I upgrade, will increase the instantaneous luminosity to about three times the design value. Since the current ATLAS trigger system does not allow sufficient increase of the trigger rate, an improvement of the trigger system is required. The Liquid Argon (LAr) Calorimeter read-out will therefore be modified to deliver digital trigger signals with a higher spatial granularity in order to improve the identification efficiencies of electrons, photons, tau, jets and missing energy, at high background rejection rates at the Level-1 trigger. The new trigger signals will be arranged in 34000 so-called Super Cells which achieves 5-10 times better granularity than the trigger towers currently used and allows an improved background rejection. The readout of the trigger signals will process the signal of the Super Cells at every LHC bunch-crossing at 12-bit precision and a frequency of 40 MHz. The data will be transmitted to the Back End using a custom serializer and optical converter and 5.12 Gb/s optical links. In order to verify the full functionality of the future Liquid Argon trigger system, a demonstrator set-up has been installed on the ATLAS detector and is operated in parallel to the regular ATLAS data taking during the LHC Run-2 in 2015 and 2016. Noise level and linearity on the energy measurement have been verified to be within our requirements. In addition, we have collected data from 13 TeV proton collisions during the LHC 2015 and 2016 runs, and have observed real pulses from the detector through the demonstrator system. The talk will give an overview of the Phase-I Upgrade of the ATLAS Liquid Argon Calorimeter readout and present the custom developed hardware including their role in real-time data processing and fast data transfer. This contribution will also report on the performance of the newly developed ASICs including their radiation tolerance and on the performance of the prototype boards in the demonstrator system based on various measurements with the 13 TeV collision data. Results of the high-speed link test with the prototypes of the final electronic boards will be also reported.
Dai, Qian; Pan, De-lu; He, Xian-qiang; Zhu, Qian-kun; Gong, Fang; Huang, Hai-qing
2015-11-01
In situ measurement of water spectrum is the basis of the validation of the ocean color remote sensing. The traditional method to obtain the water spectrum is based on the shipboard measurement at limited stations, which is difficult to meet the requirement of validation of ocean color remote sensing in the highly dynamic coastal waters. To overcome this shortage, continuously observing systems of water spectrum have been developed in the world. However, so far, there are still few high-frequency observation systems of the water spectrum in coastal waters, especially in the highly turbid and high-dynamic waters. Here, we established a high-frequency water-spectrum observing system based on tower in the Hangzhou Bay. The system measures the water spectrum at a step of 3 minutes, which can fully match the satellite observation. In this paper, we primarily developed a data processing method for the tower-based high-frequency water spectrum data, to realize automatic judgment of clear sky, sun glint, platform shadow, and weak illumination, etc. , and verified the processing results. The results show that the normalized water-leaving radiance spectra obtained through tower observation have relatively high consistency with the shipboard measurement results, with correlation coefficient of more than 0. 99, and average relative error of 9.96%. In addition, the long-term observation capability of the tower-based high-frequency water-spectrum observing system was evaluated, and the results show that although the system has run for one year, the normalized water-leaving radiance obtained by this system have good consistency with the synchronously measurement by Portable spectrometer ASD in respect of spectral shape and value, with correlation coefficient of more than 0.90 and average relative error of 6.48%. Moreover, the water spectra from high-frequency observation by the system can be used to effectively monitor the rapid dynamic variation in concentration of suspended materials with tide. The tower-based high-frequency water-spectrum observing system provided rich in situ spectral data for the validation of ocean color remote sensing in turbid waters, especially for validation of the high temporal-resolution geostationary satellite ocean color remote sensing.
Developing a Data Driven Process-Based Model for Remote Sensing of Ecosystem Production
NASA Astrophysics Data System (ADS)
Elmasri, B.; Rahman, A. F.
2010-12-01
Estimating ecosystem carbon fluxes at various spatial and temporal scales is essential for quantifying the global carbon cycle. Numerous models have been developed for this purpose using several environmental variables as well as vegetation indices derived from remotely sensed data. Here we present a data driven modeling approach for gross primary production (GPP) that is based on a process based model BIOME-BGC. The proposed model was run using available remote sensing data and it does not depend on look-up tables. Furthermore, this approach combines the merits of both empirical and process models, and empirical models were used to estimate certain input variables such as light use efficiency (LUE). This was achieved by using remotely sensed data to the mathematical equations that represent biophysical photosynthesis processes in the BIOME-BGC model. Moreover, a new spectral index for estimating maximum photosynthetic activity, maximum photosynthetic rate index (MPRI), is also developed and presented here. This new index is based on the ratio between the near infrared and the green bands (ρ858.5/ρ555). The model was tested and validated against MODIS GPP product and flux measurements from two eddy covariance flux towers located at Morgan Monroe State Forest (MMSF) in Indiana and Harvard Forest in Massachusetts. Satellite data acquired by the Advanced Microwave Scanning Radiometer (AMSR-E) and MODIS were used. The data driven model showed a strong correlation between the predicted and measured GPP at the two eddy covariance flux towers sites. This methodology produced better predictions of GPP than did the MODIS GPP product. Moreover, the proportion of error in the predicted GPP for MMSF and Harvard forest was dominated by unsystematic errors suggesting that the results are unbiased. The analysis indicated that maintenance respiration is one of the main factors that dominate the overall model outcome errors and improvement in maintenance respiration estimation will result in improved GPP predictions. Although there might be a room for improvements in our model outcomes through improved parameterization, our results suggest that such a methodology for running BIOME-BGC model based entirely on routinely available data can produce good predictions of GPP.
Peng, X; Pei, H; Li, X; He, X; Yang, A; Tang, Y; Cao, R
2000-08-01
To understand the situation of Legionella-contamination at cooling towers of big hotel and the level of Legionella-infection among related populations in Beijing. Thirty-eight cooling towers of hotels were chosen for detection of Legionella. Four hundred and fourteen staff members from the hotels were selected as exposure group, with another 414 from general population as controls, for the detection of Legionella antibodies. Sixteen strains of Legionella pneumophila (Lp) were isolated from 21 of the 38 cooling towers, and the predominant strain was Lp serum group 1 (50%, 8/16). The seroprevalence of Lp antibodies for the exposure group was 9.9% (41/414), comparing to 3.5% (14/414) from the control group. The difference was statistically significant (chi(2) = 14.2, P < 0.01). Legionella was discovered in air-conditioning cooling tower of the hotels, which threatened the health to the population exposed to it.
Fluctuations in running and skill-related performance in elite rugby union match-play.
Lacome, Mathieu; Piscione, Julien; Hager, Jean-Philippe; Carling, Chris
2017-03-01
This study investigated end-game and transient changes in running activities and whether these were concomitantly associated with reductions in skill-related performance in senior international rugby union match-play. Altogether, 18 official matches were analysed (322 individual observations) using computerised video-based tracking and event coding (Amisco Pro ® , SUP, Nice, France). In forwards and backs, trivial to small reductions (% difference: -2.1, ±1.3 to -10.0, ±4.0%) in total distance and that covered at high speeds (>18.0 km h -1 ) occurred in the second- versus the first-half while there were trivial differences in skill-related performance measures (-2.3, ±4.5 to 7.5, ±14.0%). In both positions, small to moderate declines (-42, ±10 to -21, ±7%) occurred in high-speed running in the final 10-min and 5-min periods versus mean values for all other 10-min and 5-min periods throughout the game while only small changes (-18, ±51 to 13, ±41%) in skill-related performance were observed. Trivial changes in running and skill-related performance (-11, ±74 to 7, ±39%) were observed in the 5-min period immediately following the most intense 5-minute periods of play compared to mean performance over the other 5-min periods. These findings suggest that international rugby union players were generally able to maintain skill-related performance over the course of match-play even when declines in running performance occurred.
From the 750 GeV diphoton resonance to multilepton excesses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bae, Kyu Jung; Chen, Chuan-Ren; Hamaguchi, Koichi
2016-07-01
Weakly coupled models for the 750 GeV diphoton resonance often invoke new particles carrying both color and/or electric charges to mediate loop-induced couplings of the resonance to two gluons and two photons. The new colored particles may not be stable and could decay into final states containing standard model particles. We consider an electroweak doublet of vectorlike quarks (VLQs) carrying electric charges of 5/3 and 2/3, respectively, which mediate the loop-induced couplings of the 750 GeV resonance. If the VLQ has a mass at around 1 TeV, it naturally gives rise to the observed diphoton signal strength while all couplingsmore » remain perturbative up to a high scale. At the same time, if the charge-5/3 VLQ decays into final states containing top quark and W boson, it would contribute to the multilepton excesses observed in both run 1 and run 2 data. It is also possible to incorporate a dark matter candidate in the decay final states to explain the observed relic density.« less
Kumar, Anoop; Gupta, S K; Kale, S R
2007-04-01
Cross-flow gravity towers are particle scrubbing devices in which water is sprayed from the top into particle-laden flow moving horizontally. Models for predicting particle capture assume drops traveling at terminal velocity and potential flow (ReD > 1000) around it, however, Reynolds numbers in the intermediate range of 1 to 1000 are common in gravity towers. Drops are usually injected at velocities greater than their terminal velocities (as in nozzles) or from near rest (perforated tray) and they accelerate/decelerate to their terminal velocity in the tower. Also, the effects of intermediate drop Reynolds number on capture efficiency have been simulated for (a) drops at their terminal velocity and (b) drops accelerating/decelerating to their terminal velocity. Tower efficiency based on potential flow about the drop is 40%-50% greater than for 200 mm drops traveling at their terminal velocity. The corresponding values for 500 mm drops are about 10%-20%. The drop injection velocity is important operating parameter. Increase in tower efficiency by about 40% for particles smaller than 5 mm is observed for increase in injection velocity from 0 to 20 m/s for 200 and 500mm drops.
2009-06-09
The Soyuz TMA-14 spacecraft, escape tower, first, second and third stages are seen after final assembly Monday, March 23, 2009 at the Baikonur Cosmodrome in Kazakhstan. The Soyuz is scheduled to launch the crew of Expedition 19 and a spaceflight participant on March 26, 2009. Photo Credit: (NASA/Bill Ingalls)
Large Wind Energy Converter: Growian 3 MW
NASA Technical Reports Server (NTRS)
Feustel, J. E.; Helm, S.; Koerber, F.
1980-01-01
The final report on the projected application of larger-scale wind turbine on the northern German coast is summarized. The designs of the tower, machinery housing, rotor, and rotor blades are described accompanied various construction materials are examined. Rotor blade adjustment devices auxiliary and accessory equipment are examined.
161. GENERAL VIEW OF BASE. VIEW SOUTH FROM DOG PATCH ...
161. GENERAL VIEW OF BASE. VIEW SOUTH FROM DOG PATCH BEACH SHOWING, FROM LEFT TO RIGHT, THE AIRFIELD, BULKHEAD, BUILDING 64, 61, 3,4,5,6, STRUCTURE 68 (WATER TOWER), BUILDING 11 AND STRUCTURE 67 (WATER TOWER). - Quonset Point Naval Air Station, Roger Williams Way, North Kingstown, Washington County, RI
Growth and development of spring towers at Shiqiang, Yunnan Province, China
NASA Astrophysics Data System (ADS)
Jones, Brian; Peng, Xiaotong
2017-01-01
Throughout the world, high artesian pressures in hydrothermal areas have led to the growth of tall spring towers that have their vents at their summits. The factors that control their development and formative precipitates are poorly understood because these springs, irrespective of location, are mostly inactive. Spring towers found at Shiqiang (Yunnan Province, China), which are up to 4 m high and 3 m in diameter, are formed largely of calcite and aragonite crystal bushes, euhedral calcite crystals and coated grains with alternating Fe-poor and Fe-rich zones, calcite rafts, and cements formed of various combinations of calcite, aragonite, strontianite, Mg-Si reticulate, needle fiber calcite, calcified and non-calcified microbes, diatoms, and insects. Collectively, the limestones that form the towers can be divided into (1) Group A that are friable, porous and form the cores of the towers and have δ18OSMOW values of + 15.7 to + 19.7‰ (average 17.8‰) and δ13CPDB values of + 5.1 to + 6.9‰ (average 5.9‰), and (2) Group B that are hard and well lithified and found largely around the vents and the tower sides, and have δ18OSMOW values of + 13.0 to + 22.0‰ (average 17.6‰) and δ13CPDB values of + 1.4 to + 3.6‰ (average 2.6‰). The precipitates and the isotopic values indicate that these were thermogene springs. Growth of the Shiqiang spring towers involved (1) Phase IA when precipitation of calcite and aragonite bushes formed the core of the tower and Phase IB when calcite, commonly Fe-rich, was precipitated locally, (2) Phase II that involved the precipitation of white cements, formed of calcite, aragonite, strontianite, and Mg-Si reticulate coatings in cavities amid the Phase I precipitates, and (3) Phase III, which formed probably after spring activity ceased, when needle-fiber calcite was precipitated and the mounds were invaded by microbes (some now calcified), diatoms, and insects. At various times during this complex history, pore waters mediated dissolution of the calcite and aragonite and sometimes partial alteration of the aragonite. The diverse array of precipitates, depositional fabrics and diagenetic changes clearly indicate that the composition of the spring water changed frequently. Growth of the spring towers at Shiqiang continued until there was insufficient artesian pressure to lift the water above the top of the tower vent.
OzFlux data: network integration from collection to curation
NASA Astrophysics Data System (ADS)
Isaac, Peter; Cleverly, James; McHugh, Ian; van Gorsel, Eva; Ewenz, Cacilia; Beringer, Jason
2017-06-01
Measurement of the exchange of energy and mass between the surface and the atmospheric boundary-layer by the eddy covariance technique has undergone great change in the last 2 decades. Early studies of these exchanges were confined to brief field campaigns in carefully controlled conditions followed by months of data analysis. Current practice is to run tower-based eddy covariance systems continuously over several years due to the need for continuous monitoring as part of a global effort to develop local-, regional-, continental- and global-scale budgets of carbon, water and energy. Efficient methods of processing the increased quantities of data are needed to maximise the time available for analysis and interpretation. Standardised methods are needed to remove differences in data processing as possible contributors to observed spatial variability. Furthermore, public availability of these data sets assists with undertaking global research efforts. The OzFlux data path has been developed (i) to provide a standard set of quality control and post-processing tools across the network, thereby facilitating inter-site integration and spatial comparisons; (ii) to increase the time available to researchers for analysis and interpretation by reducing the time spent collecting and processing data; (iii) to propagate both data and metadata to the final product; and (iv) to facilitate the use of the OzFlux data by adopting a standard file format and making the data available from web-based portals. Discovery of the OzFlux data set is facilitated through incorporation in FLUXNET data syntheses and the publication of collection metadata via the RIF-CS format. This paper serves two purposes. The first is to describe the data sets, along with their quality control and post-processing, for the other papers of this Special Issue. The second is to provide an example of one solution to the data collection and curation challenges that are encountered by similar flux tower networks worldwide.
Federal Aviation Administration Aviation System Capital Investment Plan 1993
1993-12-01
Facilitates full use of terminal airspace capacity. 0 Increases safety and efficiency. 62-21 Airport Surface Traffic 0 Optimizes sequencing and...installation of tower control computer complexes (TCCCs) in se- 0 AAS software for terminal and en route ATC lected airport traffic control towers. TCCCs...project provides economical ASR-4/5/6, and install 40 ASR-9s at radar service at airports with air traffic densi- ASR-4/5/6 sites). ties high enough to
Effects of Airport Tower Controller Decision Support Tool on Controllers Head-Up Time
NASA Technical Reports Server (NTRS)
Hayashi, Miwa; Cruz Lopez, Jose M.
2013-01-01
Despite that aircraft positions and movements can be easily monitored on the radar displays at major airports nowadays, it is still important for the air traffic control tower (ATCT) controllers to look outside the window as much as possible to assure safe operations of traffic management. The present paper investigates whether an introduction of the NASA's proposed Spot and Runway Departure Advisor (SARDA), a decision support tool for the ATCT controller, would increase or decrease the controllers' head-up time. SARDA provides the controller departure-release schedule advisories, i.e., when to release each departure aircraft in order to minimize individual aircraft's fuel consumption on taxiways and simultaneously maximize the overall runway throughput. The SARDA advisories were presented on electronic flight strips (EFS). To investigate effects on the head-up time, a human-in-the-loop simulation experiment with two retired ATCT controller participants was conducted in a high-fidelity ATCT cab simulator with 360-degree computer-generated out-the-window view. Each controller participant wore a wearable video camera on a side of their head with the camera facing forward. The video data were later used to calculate their line of sight at each moment and eventually identify their head-up times. Four sessions were run with the SARDA advisories, and four sessions were run without (baseline). Traffic-load levels were varied in each session. The same set of user interface - EFS and the radar displays - were used in both the advisory and baseline sessions to make them directly comparable. The paper reports the findings and discusses their implications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fedorchenko, O.A.; Aleksee, I.A.; Bondarenko, S.D.
2015-03-15
Hundreds of thousands of tons of tritiated light water have been accumulating from the enterprises of nuclear fuel cycles around the world. The Dual-Temperature Water-Hydrogen (DTWH) process looks like the only practical alternative to Combined Electrolysis and Catalytic Exchange (CECE). In DTWH power-consuming lower reflux device (electrolytic cell) is replaced by a so-called 'hot tower' (LPCE column operating at conditions which ensure relatively small value of elementary separation factor α(hot)). In the upper, cold tower, the tritium transfers from hydrogen to water while in the lower, hot tower - in the opposite direction - from water to hydrogen. The DTWHmore » process is much more complicated compared to CECE; it must be thoroughly computed and strictly controlled by an automatic control system. The use of a simulation code for DTWH is absolutely important. The simulation code EVIO-5 deals with 3 flows inside a column (hydrogen gas, water vapour and liquid water) and 2 simultaneous isotope exchange sub-processes (counter-current phase exchange and co-current catalytic exchange). EVIO-5 takes into account the strong dependence of process performance on given conditions (temperature and pressure). It calculates steady-state isotope concentration profiles considering a full set of reversible exchange reactions between different isotope modifications of water and hydrogen (12 molecular species). So the code can be used for simulation of LPCE column operation for detritiation of hydrogen and water feed, which contains H and D not only at low concentrations but above 10 at.% also. EVIO-5 code is used to model a Tritium Removal Facility with a throughput capacity of about 400 m{sup 3}/day. Simulation results show that a huge amount of wet-proofed catalyst is required (about 6000 m{sup 3}), mainly (90%) in the first stage. One reason for these large expenses (apart from a big scale of the problem itself) is the relatively high tritium separation factor in the hot tower. The introduction of some quantity of deuterium into the gaseous flow before the hot tower lowers the tritium separation factor in that column. One possible variant of deuterium introduction to the hot tower of the first stage was modelled. The decontamination capacity increases by a 2.5 factor.« less
Analysis the configuration of earthing system based on high-low and low-high soil structure
NASA Astrophysics Data System (ADS)
Ramani, A. N.; Ahmad, Abdul Rahman; Sulaima, M. F.; Nasir, M. N. M.; Ahmad, Arfah
2015-05-01
Each TNB transmission tower requires a tower footing resistance (TFR) with a lower grounding resistance value that depends on the transmission line voltage. For 132kV and 275kV tower, the TFR must less than 10Ω and 500kV tower must less than 5Ω. The TFR is changeable with variable factors such as soil resistivity. Low TFR provides essential protection to the fault such as lightning strike that may occur at any time. The fault current flow to the lowest resistance path and easily disperses to earth. Back flashover voltage across the insulator of transmission lines may occur when the TFR is high. The TFR is influenced by soil resistivity. There are three parameters affecting the soil resistivity; moisture content, salt content and temperature of the soil. High moisture content in soil will reduce the soil resistivity and resultant low TFR. Small scale moisture control by using Micro Reservoir (MR) irrigation with semi-permeable membranes have the power to offer the stable moisture in soil. By using osmosis concept, it is the process of net movement of water molecules from high potential water to lower potential water though a semi permeable membrane. The MR can withstand for 3 to 5 days without continuous water supply. The MR installed in the centre of the tower that contains a multiple parallel of electrode rods. The concentrated of electrode rods grounding configuration with a combination of MR will improve the TFR even at multilayer soil. As a result, MR gives a little improvement to TFR. The MR in area of concentrated electrode rod configuration to ensure the soil always wet and moist at all times. The changes in soil affect the tower-footing-resistance. The tower-footing-resistance measurement at afternoon is higher than at evening because of the temperature and moisture content in soil is change due to sun radiation.
NASA Astrophysics Data System (ADS)
Wang, Miao; Wang, Jin; Wang, Jiajin; Shi, Cheng
2018-02-01
A three-dimensional (3D) numerical model is established and validated for cooling performance optimization between a high-level water collecting natural draft wet cooling tower (HNDWCT) and a usual natural draft wet cooling tower (UNDWCT) under the actual operation condition at Wanzhou power plant, Chongqing, China. User defined functions (UDFs) of source terms are composed and loaded into the spray, fill and rain zones. Considering the conditions of impact on three kinds of corrugated fills (Double-oblique wave, Two-way wave and S wave) and four kinds of fill height (1.25 m, 1.5 m, 1.75 m and 2 m), numerical simulation of cooling performance are analysed. The results demonstrate that the S wave has the highest cooling efficiency in three fills for both towers, indicating that fill characteristics are crucial to cooling performance. Moreover, the cooling performance of the HNDWCT is far superior to that of the UNDWCT with fill height increases of 1.75 m and above, because the air mass flow rate in the fill zone of the HNDWCT improves more than that in the UNDWCT, as a result of the rain zone resistance declining sharply for the HNDWCT. In addition, the mass and heat transfer capacity of the HNDWCT is better in the tower centre zone than in the outer zone near the tower wall under a uniform fill layout. This behaviour is inverted for the UNDWCT, perhaps because the high-level collection devices play the role of flow guiding in the inner zone. Therefore, when non-uniform fill layout optimization is applied to the HNDWCT, the inner zone increases in height from 1.75 m to 2 m, the outer zone reduces in height from 1.75 m to 1.5 m, and the outlet water temperature declines approximately 0.4 K compared to that of the uniform layout.
Analysis the configuration of earthing system based on high-low and low-high soil structure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ramani, A. N.; Ahmad, Abdul Rahman; Sulaima, M. F.
2015-05-15
Each TNB transmission tower requires a tower footing resistance (TFR) with a lower grounding resistance value that depends on the transmission line voltage. For 132kV and 275kV tower, the TFR must less than 10Ω and 500kV tower must less than 5Ω. The TFR is changeable with variable factors such as soil resistivity. Low TFR provides essential protection to the fault such as lightning strike that may occur at any time. The fault current flow to the lowest resistance path and easily disperses to earth. Back flashover voltage across the insulator of transmission lines may occur when the TFR is high.more » The TFR is influenced by soil resistivity. There are three parameters affecting the soil resistivity; moisture content, salt content and temperature of the soil. High moisture content in soil will reduce the soil resistivity and resultant low TFR. Small scale moisture control by using Micro Reservoir (MR) irrigation with semi-permeable membranes have the power to offer the stable moisture in soil. By using osmosis concept, it is the process of net movement of water molecules from high potential water to lower potential water though a semi permeable membrane. The MR can withstand for 3 to 5 days without continuous water supply. The MR installed in the centre of the tower that contains a multiple parallel of electrode rods. The concentrated of electrode rods grounding configuration with a combination of MR will improve the TFR even at multilayer soil. As a result, MR gives a little improvement to TFR. The MR in area of concentrated electrode rod configuration to ensure the soil always wet and moist at all times. The changes in soil affect the tower-footing-resistance. The tower-footing-resistance measurement at afternoon is higher than at evening because of the temperature and moisture content in soil is change due to sun radiation.« less
Running increases ethanol preference.
Werme, Martin; Lindholm, Sara; Thorén, Peter; Franck, Johan; Brené, Stefan
2002-07-18
Wheel running performed by rats is reinforcing, rewarding and possibly addictive. In this study we analyzed if wheel running could affect ethanol preference. Lewis rats, known to be both addiction-prone and to develop an excessive wheel running behavior, were given access to ethanol in a two-bottle free-choice paradigm. The animals reached a high and stable ethanol intake after 5 weeks. In the next phase, rats were subjected to ethanol withdrawal for 1, 2 or 4 weeks with or without access to running wheels. Finally animals were again given access to ethanol in the same two-bottle free-choice paradigm, combined with access to running wheels. The rats that ran in running wheels during 1 or 2, but not 4, weeks of ethanol withdrawal increased both ethanol intake and preference as compared with the control group that did not have access to the wheels. Previous studies have demonstrated that low doses of morphine increases ethanol preference. Here we show that also running potentiates ethanol intake and preference. Thus, running which shares many of the reinforcing properties with addictive drugs appears to potentiate rats to an increased preference for ethanol. Our results describe a behavioral interaction where running increases ethanol consumption.
When Venture Philanthropy Rocks the Ivory Tower
ERIC Educational Resources Information Center
Boverini, Luisa
2006-01-01
This essay explores the implication of venture philanthropy for higher education fund raising. The author provides a detailed description of venture philanthropy, including the social context driving its development. Then, the benefits brought to higher education by this style of philanthropy are explored. Finally, a single example of venture…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-09
... facility, a wind farm, a methane- gas cofiring facility, and several small solar photovoltaic facilities... maintenance of select plant systems and other regulatory compliance activities. Major buildings and plant... the plant cooling towers and the reactor, auxiliary, control, turbine, office, and service buildings...
40 CFR 423.17 - Pretreatment standards for new sources (PSNS).
Code of Federal Regulations, 2014 CFR
2014-07-01
... discharged in chemical metal cleaning wastes shall not exceed the concentration listed in the following table... chemicals added for cooling tower maintenance, except: Chromium, total 0.2 Zinc, total 1.0 (2) At the... engineering calculations which demonstrate that the regulated pollutants are not detectable in the final...
40 CFR 423.17 - Pretreatment standards for new sources (PSNS).
Code of Federal Regulations, 2010 CFR
2010-07-01
... discharged in chemical metal cleaning wastes shall not exceed the concentration listed in the following table... chemicals added for cooling tower maintenance, except: Chromium, total 0.2 Zinc, total 1.0 (2) At the... engineering calculations which demonstrate that the regulated pollutants are not detectable in the final...
40 CFR 423.17 - Pretreatment standards for new sources (PSNS).
Code of Federal Regulations, 2012 CFR
2012-07-01
... discharged in chemical metal cleaning wastes shall not exceed the concentration listed in the following table... chemicals added for cooling tower maintenance, except: Chromium, total 0.2 Zinc, total 1.0 (2) At the... engineering calculations which demonstrate that the regulated pollutants are not detectable in the final...
40 CFR 423.17 - Pretreatment standards for new sources (PSNS).
Code of Federal Regulations, 2011 CFR
2011-07-01
... discharged in chemical metal cleaning wastes shall not exceed the concentration listed in the following table... chemicals added for cooling tower maintenance, except: Chromium, total 0.2 Zinc, total 1.0 (2) At the... engineering calculations which demonstrate that the regulated pollutants are not detectable in the final...
40 CFR 423.17 - Pretreatment standards for new sources (PSNS).
Code of Federal Regulations, 2013 CFR
2013-07-01
... discharged in chemical metal cleaning wastes shall not exceed the concentration listed in the following table... chemicals added for cooling tower maintenance, except: Chromium, total 0.2 Zinc, total 1.0 (2) At the... engineering calculations which demonstrate that the regulated pollutants are not detectable in the final...
Gold Run Pass - Div. of Mining, Land, and Water
issuing a Final Findings of Fact and Decision for the renewal of the Gold Run Pass Mine permits. Documents : Final Findings and Decision(PDF)(Posted 9/2/2016) Public Notice of Final Findings and Decision (PDF
DOT National Transportation Integrated Search
1973-12-01
Stress in controllers on the straight five-day shift was determined at Houston Intercontinental Tower in 1970. In 1971 controllers on the 2-2-1 rotation were studied at the same tower. Controllers generally prefer the 2-2-1 to the straight five-day s...
77 FR 62378 - Supervisory and Company-Run Stress Test Requirements for Covered Companies
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-12
... to Both Supervisory and Company-Run Stress Tests The Board designed the final rule in a manner to... to conduct supervisory stress test; and project a company's losses, pre-provision net revenue...-Run Stress Test Requirements; Final Rules #0;#0;Federal Register / Vol. 77 , No. 198 / Friday, October...
Degeneracy breakdown as a source of supernovae Ia
NASA Astrophysics Data System (ADS)
Clavelli, L.
2018-01-01
In a confined system of multiple Fermions, the particles are forced into high energy levels by the Pauli Exclusion Principle. We refer to this system as a Pauli tower. We pursue the investigation of a model for sub-Chandrasekhar supernovae Ia explosions (SNIa) in which the energy stored in the Pauli tower is released to trigger a nuclear deflagration. The simplest physical model for such a degeneracy breakdown and collapse of the Pauli tower is a phase transition to an exactly supersymmetric state in which the scalar partners of protons, neutrons, and leptons become degenerate with the familiar fermions of our world as in the supersymmetric standard model with susy breaking parameters relaxed to zero. We focus on the ability of the susy phase transition model to fit the total SNIa rate as well as the delay time distribution of SNIa after the birth of a progenitor white dwarf. We also study the ejected mass distribution and its correlation with delay time. Finally, we discuss the expected SNIa remnant in the form of a black hole of roughly Jupiter mass and the prospects for detecting such remnants.
Benowitz, Isaac; Fitzhenry, Robert; Boyd, Christopher; Dickinson, Michelle; Levy, Michael; Lin, Ying; Nazarian, Elizabeth; Ostrowsky, Belinda; Passaretti, Teresa; Rakeman, Jennifer; Saylors, Amy; Shamoonian, Elena; Smith, Terry-Ann; Balter, Sharon
2018-04-01
We investigated an outbreak of eight Legionnaires' disease cases among persons living in an urban residential community of 60,000 people. Possible environmental sources included two active cooling towers (air-conditioning units for large buildings) <1 km from patient residences, a market misting system, a community-wide water system used for heating and cooling, and potable water. To support a timely public health response, we used real-time polymerase chain reaction (PCR) to identify Legionella DNA in environmental samples within hours of specimen collection. We detected L. pneumophila serogroup 1 DNA only at a power plant cooling tower, supporting the decision to order remediation before culture results were available. An isolate from a power plant cooling tower sample was indistinguishable from a patient isolate by pulsed-field gel electrophoresis, suggesting the cooling tower was the outbreak source. PCR results were available <1 day after sample collection, and culture results were available as early as 5 days after plating. PCR is a valuable tool for identifying Legionella DNA in environmental samples in outbreak settings.
Gargano, Lisa M; Nguyen, Angela; DiGrande, Laura; Brackbill, Robert M
2016-09-01
Studies of individuals directly exposed to the World Trade Center (WTC) terrorist attacks of September 11, 2001 have found increased risk for post-traumatic stress disorder (PTSD) and binge drinking (BD). No long-term studies have been conducted on one highly exposed group, WTC tower evacuees. The study sample included 7,695 adult civilians in the WTC Health Registry. Logistic regression was used to examine the odds of PTSD and BD in 1,946 towers evacuees compared to 5,749 others in nearby buildings or on the street. WTC tower survivors were at increased risk for PTSD and BD compared to the others. Infrastructure and behavioral barriers experienced during evacuation were significantly associated with PTSD. WTC tower evacuees are at increased risk for PTSD and BD. Understanding the effects of disaster-related evacuation barriers on the long-term mental health status of survivors can help in the planning of continuing post-disaster treatment. Am. J. Ind. Med. 59:742-751, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
View of the docked Node 1 and FGB modules with umbilical cables attached
1998-12-08
S88-E-5061 (12-08-98) --- Cables and wires in place on the Unity module signify the end of the first of three spacewalks scheduled for the STS-88 mission. Astronauts Jerry L. Ross and James H. Newman, both mission specialists, were succesful in mating 40 cables and connectors running 76 feet from the Zarya control module (seen at top in this photo) to Unity, with the 35-ton complex towering over Endeavour's cargo bay. This photo was taken with an electronic still camera (ESC) at 03:37:35 GMT, Dec. 8.
1998-12-07
S88-E-5060 (12-08-98) --- Astronaut James H. Newman is seen near the Unity module during late phases of the first of three scheduled spacewalks on STS-88. At the end of the extravehicular activity (EVA), astronauts Newman and Jerry L. Ross, both mission specialists, were successful in mating 40 cables and connectors running 76 feet from the Zarya control module to Unity, with the 35-ton complex towering over Endeavour's cargo bay. The spacewalk last 7 hours and 21 minutes. This photo was taken with an electronic still camera (ESC) at 03:50:28 GMT, Dec. 8.
NASA Astrophysics Data System (ADS)
Winney, Peter E.
1989-07-01
A standard 660MW turbo-alternator, operated by the CEGB, runs at an energy conversion efficiency of about 38%. In addition to the 660MW electrical power, 600MW of waste thermal power is generated which has to be dissipated via water cooled heat exchangers. A typical 2000MW station has a requirement of about 1.3 billion gallons of cooling water per day. This is more than the daily throughput of most of our rivers and so inland stations are equipped with cooling towers to dump heat from the coolant.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clifford, Megan
Infrastructure is, by design, largely unnoticed until it breaks down and services fail. This includes water supplies, gas pipelines, bridges and dams, phone lines and cell towers, roads and culverts, railways, and the electric grid—all of the complex systems that keep our societies and economies running. Climate change, population growth, increased urbanization, system aging, and outdated design standards stress existing infrastructure and its ability to satisfy the rapidly changing demands from users. Here, the resilience of both physical and cyber infrastructure systems, however, is critical to a community as it prepares for, responds to, and recovers from a disaster, whethermore » natural or man-made.« less
Improved WIMP-search reach of the CDMS II germanium data
Agnese, R.
2015-10-12
CDMS II data from the five-tower runs at the Soudan Underground Laboratory were reprocessed with an improved charge-pulse fitting algorithm. Two new analysis techniques to reject surface-event backgrounds were applied to the 612 kg days germanium-detector weakly interacting massive particle (WIMP)-search exposure. An extended analysis was also completed by decreasing the 10 keV analysis threshold to ~5 keV, to increase sensitivity near a WIMP mass of 8 GeV/c 2. After unblinding, there were zero candidate events above a deposited energy of 10 keV and six events in the lower-threshold analysis. This yielded minimum WIMP-nucleon spin-independent scattering cross-section limits of 1.8×10more » –44 and 1.18×10 –41 at 90% confidence for 60 and 8.6 GeV/c 2 WIMPs, respectively. This improves the previous CDMS II result by a factor of 2.4 (2.7) for 60 (8.6) GeV/c 2 WIMPs.« less
Improved WIMP-search reach of the CDMS II germanium data
Agnese, R.
2015-10-12
CDMS II data from the five-tower runs at the Soudan Underground Laboratory were reprocessed with an improved charge-pulse fitting algorithm. Two new analysis techniques to reject surface-event backgrounds were applied to the 612 kg days germanium-detector weakly interacting massive particle (WIMP)-search exposure. An extended analysis was also completed by decreasing the 10 keV analysis threshold to ~5 keV, to increase sensitivity near a WIMP mass of 8 GeV/c 2. After unblinding, there were zero candidate events above a deposited energy of 10 keV and six events in the lower-threshold analysis. This yielded minimum WIMP-nucleon spin-independent scattering cross-section limits of 1.8×10more » –44 and 1.18×10 –41 at 90% confidence for 60 and 8.6 GeV/c 2 WIMPs, respectively. Furthermore, this improves the previous CDMS II result by a factor of 2.4 (2.7) for 60 (8.6) GeV/c 2 WIMPs.« less
NASA Marshall Space Flight Center solar observatory report, January - June 1991
NASA Technical Reports Server (NTRS)
Smith, James E.
1991-01-01
Given here is a summary of the solar vector magnetic field, H-alpha, and white-light observations made at the NASA/Marshall Space Flight Center (MSFC) Solar Observatory during its daily periods of operation. The MSFC Solar Observatory facilities consist of the Solar Magnetograph, an f/13, 30-cm Cassegrain system with a 3.5-cm image of the Sun, housed on top of a 12.8-meter tower; a 12.5-cm Razdow H-alpha telescope housed at the base of the tower; an 18-cm Questar telescope with a full aperture white-light filter mounted at the base of the tower; a 30-cm Cassegrain telescope located in a second metal dome; and a 16.5-cm H-alpha telescope mounted on side of the Solar Vector Magnetograph. A concrete block building provides office space, a darkroom for developing film and performing optical testing, a workshop, video displays, and a computer facility for data reduction.
NASA Marshall Space Flight Center Solar Observatory report, July - December 1991
NASA Technical Reports Server (NTRS)
Smith, James E.
1992-01-01
A summary is given of the solar vector magnetic field, H-alpha, and white light observations made at the NASA/Marshall Space Flight Center (MSFC) Solar Observatory during its daily periods of observation. The MSFC Solar Observatory facilities consist of the Solar Magnetograph, an f-13, 30 cm Cassegrain system with a 3.5 cm image of the Sun housed on top of a 12.8 meter tower, a 12.5 cm Razdow H-alpha telescope housed at the base of the tower, an 18 cm Questar telescope with a full aperture white-light filter mounted at the base of the tower, a 30 cm Cassegrain telescope located in a second metal dome, and a 16.5 cm H-alpha telescope mounted on the side of the Solar Vector Magnetograph. A concrete block building provides office space, a darkroom for developing film and performing optical testing, a workshop, video displays, and a computer facility for data reduction.
Vikmoen, Olav; Rønnestad, Bent R; Ellefsen, Stian; Raastad, Truls
2017-03-01
The purpose of this study was to investigate the effects of adding heavy strength training to female duathletes' normal endurance training on both cycling and running performance. Nineteen well-trained female duathletes ( V O 2max cycling: 54 ± 3 ml∙kg -1 ∙min -1 , VO 2max running: 53 ± 3 ml∙kg -1 ∙min -1 ) were randomly assigned to either normal endurance training ( E , n = 8) or normal endurance training combined with strength training ( E+S , n = 11). The strength training consisted of four lower body exercises [3 × 4-10 repetition maximum (RM)] twice a week for 11 weeks. Running and cycling performance were assessed using 5-min all-out tests, performed immediately after prolonged periods of submaximal work (3 h cycling or 1.5 h running). E+S increased 1RM in half squat (45 ± 22%) and lean mass in the legs (3.1 ± 4.0%) more than E Performance during the 5-min all-out test increased in both cycling (7.0 ± 4.5%) and running (4.7 ± 6.0%) in E+S, whereas no changes occurred in E The changes in running performance were different between groups. E+S reduced oxygen consumption and heart rate during the final 2 h of prolonged cycling, whereas no changes occurred in E No changes occurred during the prolonged running in any group. Adding strength training to normal endurance training in well-trained female duathletes improved both running and cycling performance when tested immediately after prolonged submaximal work. © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.
Load reduction of a monopile wind turbine tower using optimal tuned mass dampers
NASA Astrophysics Data System (ADS)
Tong, Xin; Zhao, Xiaowei; Zhao, Shi
2017-07-01
We investigate to apply tuned mass dampers (TMDs) (one in the fore-aft direction, one in the side-side direction) to suppress the vibration of a monopile wind turbine tower. Using the spectral element method, we derive a finite-dimensional state-space model Σd from an infinite-dimensional model Σ of a monopile wind turbine tower stabilised by a TMD located in the nacelle. Σ and Σd can be used to represent the dynamics of the tower and TMD in either the fore-aft direction or the side-side direction. The wind turbine tower subsystem of Σ is modelled as a non-uniform SCOLE (NASA Spacecraft Control Laboratory Experiment) system consisting of an Euler-Bernoulli beam equation describing the dynamics of the flexible tower and the Newton-Euler rigid body equations describing the dynamics of the heavy rotor-nacelle assembly (RNA) by neglecting any coupling with blade motions. Σd can be used for fast and accurate simulation for the dynamics of the wind turbine tower as well as for optimal TMD designs. We show that Σd agrees very well with the FAST (fatigue, aerodynamics, structures and turbulence) simulation of the NREL 5-MW wind turbine model. We optimise the parameters of the TMD by minimising the frequency-limited ?-norm of the transfer function matrix of Σd which has input of force and torque acting on the RNA, and output of tower-top displacement. The performances of the optimal TMDs in the fore-aft and side-side directions are tested through FAST simulations, which achieve substantial fatigue load reductions. This research also demonstrates how to optimally tune TMDs to reduce vibrations of flexible structures described by partial differential equations.
Influence of liquid and gas flow rates on sulfuric acid mist removal from air by packed bed tower
2012-01-01
The possible emission of sulfuric acid mists from a laboratory scale, counter-current packed bed tower operated with a caustic scrubbing solution was studied. Acid mists were applied through a local exhaust hood. The emissions from the packed bed tower were monitored in three different categories of gas flow rate as well as three liquid flow rates, while other influencing parameters were kept almost constant. Air sampling and sulfuric acid measurement were carried out iso-kinetically using USEPA method 8. The acid mists were measured by the barium-thorin titration method. According to the results when the gas flow rate increased from 10 L/s to 30 L/s, the average removal efficiency increased significantly (p < 0.001) from 76.8 ± 1.8% to 85.7 ± 1.2%. Analysis of covariance method followed by Tukey post-hoc test of 92 tests did not show a significant change in removal efficiency between liquid flow rates of 1.5, 2.5 and 3.5 L/min (p = 0.811). On the other hand, with fixed pressure loss across the tower, by increasing the liquid/gas (L/G) mass ratio, the average removal efficiency decreased significantly (p = 0.001) from 89.9% at L/G of <2 to 83.1% at L/G of 2–3 and further to 80.2% at L/G of >3, respectively. L/G of 2–3 was recommended for designing purposes of a packed tower for sulfuric acid mists and vapors removal from contaminated air stream. PMID:23369487
A Global Study of GPP focusing on Light Use Efficiency in a Random Forest Regression Model
NASA Astrophysics Data System (ADS)
Fang, W.; Wei, S.; Yi, C.; Hendrey, G. R.
2016-12-01
Light use efficiency (LUE) is at the core of mechanistic modeling of global gross primary production (GPP). However, most LUE estimates in global models are satellite-based and coarsely measured with emphasis on environmental variables. Others are from eddy covariance towers with much greater spatial and temporal data quality and emphasis on mechanistic processes, but in a limited number of sites. In this paper, we conducted a comprehensive global study of tower-based LUE from 237 FLUXNET towers, and scaled up LUEs from in-situ tower level to global biome level. We integrated key environmental and biological variables into the tower-based LUE estimates, at 0.5o x 0.5o grid-cell resolution, using a random forest regression (RFR) approach. We then developed an RFR-LUE-GPP model using the grid-cell LUE data, and compared it to a tower-LUE-GPP model by the conventional way of treating LUE as a series of biome-specific constants. In order to calibrate the LUE models, we developed a data-driven RFR-GPP model using a random forest regression method. Our results showed that LUE varies largely with latitude. We estimated a global area-weighted average of LUE at 1.21 gC m-2 MJ-1 APAR, which led to an estimated global GPP of 102.9 Gt C /year from 2000 to 2005. The tower-LUE-GPP model tended to overestimate forest GPP in tropical and boreal regions. Large uncertainties exist in GPP estimates over sparsely vegetated areas covered by savannas and woody savannas around the middle to low latitudes (i.g. 20oS to 40oS and 5oN to 15oN) due to lack of available data. Model results were improved by incorporating Köppen climate types to represent climate /meteorological information in machine learning modeling. This shed new light on the recognized issues of climate dependence of spring onset of photosynthesis and the challenges in modeling the biome GPP of evergreen broad leaf forests (EBF) accurately. The divergent responses of GPP to temperature and precipitation at mid-high latitudes and at mid-low latitudes echoed the necessity of modeling GPP separately by latitudes. This work provided a global distribution of LUE estimate, and developed a comprehensive algorithm modeling global terrestrial carbon with high spatial and temporal resolutions.
SENER molten salt tower technology. Ouarzazate NOOR III case
NASA Astrophysics Data System (ADS)
Relloso, Sergio; Gutiérrez, Yolanda
2017-06-01
NOOR III 150 MWe project is the evolution of Gemasolar (19.9 MWe) to large scale Molten Salt Tower plants. With more than 5 years of operational experience, Gemasolar lessons learned have been the starting point for the optimization of this technology, considered the leader of potential cost reduction in CSP. In addition, prototypes of plant key components (heliostat and receiver) were manufactured and thoroughly tested before project launch in order to prove the new engineering solutions adopted. The SENER proprietary technology of NOOR III will be applied in the next Molten Salt Tower plants that will follow in other countries, such as South Africa, Chile and Australia.
Virtual Planning at Work: A Tour of NASA Future Flight Central
NASA Technical Reports Server (NTRS)
McClenahen, Jim; Dorighi, Nancy S. (Technical Monitor)
2000-01-01
FutureFlight Central will permit integration of tomorrow's technologies in a risk-free simulation of any airport, airfield, and tower cab environment. The facility provides an opportunity for airlines to mitigate passenger delays by fine tuning airport hub operations, gate management and ramp movement procedures. It also allows airport managers an opportunity to study effects of various improvements at their airports. Finally, it enables air traffic controllers to provide feedback and to become familiar with new airport operations and technologies before final installation.
Costs and description of a solar-energy system--Austin, Texas
NASA Technical Reports Server (NTRS)
1981-01-01
Heating and cooling system uses Fresnel lens concentrating collectors. Major system components are 36 collectors, 1,500 gallon thermal storage tank, absorption cooler, cooling tower, heating coil, pumps, heat exchanger, and backup heating and air conditioning. Final report includes detailed breakdown of component and installation costs for seven project subsystems.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-21
... 1625-AA11 Regulated Navigation Area; Waldo-Hancock Bridge Demolition, Penobscot River, Between Prospect... River between Prospect and Verona, ME, under and surrounding the Waldo- Hancock Bridge in order to facilitate the removal of the trusses, cables, and towers of the Waldo-Hancock Bridge. This temporary final...
NASA Astrophysics Data System (ADS)
Yagüe, C.; Maqueda, G.; Ramos, D.; Sastre, M.; Viana, S.; Serrano, E.; Morales, G.; Ayarzagüena, B.; Viñas, C.; Sánchez, E.
2009-04-01
An Atmospheric Boundary Layer campaign was developed in Spain along June 2008 at the CIBA (Research Centre for the Lower Atmosphere) site which is placed on a fairly homogeneous terrain in the centre of an extensive plateau (41°49' N, 4°56' W). Different instrumentation at several levels was available on a new 10m meteorological mast, including temperature and humidity sensors, wind vanes and cup anemometers, as well as one sonic anemometer. Besides, two quartz-based microbarometers were installed at 50 and 100m on the main permanent 100m tower placed at CIBA. Three additional microbarometers were deployed on the surface on a triangular array of approximately 200 m side, and a tethered balloon was used in order to record vertical profiles of temperature, wind and humidity up to 1000m. Finally, a GRIMM particle monitor (MODEL 365), which can be used to continuously measure each six seconds simultaneously the PM10, PM2.5 and PM1 values, was deployed at 1.5m. This work will show some preliminary results from the campaign CIBA 2008, analysing the main physical processes present in the atmospheric Nocturnal Boundary Layer (NBL), the different stability periods observed and the corresponding turbulent parameters, as well as the coherent structures detected. The pressure perturbations measured from the surface and tower levels make possible to study the main wave parameters from wavelet transform, and compared the structures detected by the microbarometers with those detected in the wind and particles records.
'Electrically-Hot' Convection and Tropical Cyclone Development in the Eastern Atlantic
NASA Technical Reports Server (NTRS)
Leppert, Kenneth, II; Petersen, Walter A.; Williams, Earle
2008-01-01
The depth and intensity of convective-scale "hot" towers in intensifying tropical disturbances has been hypothesized to play a role in tropical cyclogenesis via dynamic and thermodynamic feedbacks on the larger meso-to-synoptic scale circulation. In this investigation we investigate the role that widespread and/or intense lightning-producing convection (i.e., "electrically-hot towers") resident in African Easterly Waves (AEW) may play in tropical cyclogenesis over the eastern Atlantic Ocean. NCEP reanalysis data for the months of July to November for the years 2004, 2006, and 2007 are analyzed for the domain of 5 N - 15 N and 500W - 300 E. Specifically, NCEP data for individual AEWs are partitioned into northerly, southerly, trough, and ridge phases using the 700 hPa meridional winds. Subsequently, information from National Hurricane Center storm reports were divided up into developing and non-developing waves (i.e. tropical cyclogenesis). Finally, composites were created of developing and non-developing waves using the NCEP variables, but with the inclusion of lightning flash count and infrared brightness temperature information. The Zeus and World Wide Lightning Location Network lightning data were used for the lightning information, and the IR brightness temperature data was extracted from the NASA global-merged infrared brightness temperature dataset.
NASA Astrophysics Data System (ADS)
Dvorska, Alice; Milan, Váňa; Vlastimil, Hanuš; Marian, Pavelka
2013-04-01
The collocated station Košetice - Křešín u Pacova, central Czech Republic, is a major research and monitoring infrastructure in the Czech Republic and central Europe. It consists of two basic components: the observatory Košetice run since 1988 by the Czech Hydrometeorological Institute and the atmospheric station (AS) Křešín u Pacova starting operation in 2013. The AS is built and run by CzechGlobe - Global Change Research Centre, Academy of Sciences of the Czech Republic and is situated 100 m far from the observatory. There are three research and monitoring activities at the collocated station providing data necessary for the research on climate and related changes. The AS Křešín u Pacova consists of a 250 m tall tower serving for ground-based and vertical gradient measurements of (i) concentrations of CO2, CO, CH4, total gaseous mercury and tropospheric ozone (continuously), (ii) elemental and organic carbon (semicontinuously), (iii) carbon and oxygen isotopes, radon, N2O, SF6 and other species (episodically), (iv) optical properties of atmospheric aerosols and (v) meteorological parameters and the boundary layer height. Further, eddy covariance measurements in the nearby agroecosystem provide data on CO2 and H2O fluxes between the atmosphere and the ecosystem. Finally, monitoring activities at the nearby small hydrological catchment Anenské povodí run under the GEOMON network enables studying local hydrological and biogeochemical cycles. These measurements are supported by the long-term monitoring of meteorological and air quality parameters at the observatory Košetice, that are representative for the central European background. The collocated station provides a big research opportunity and challenge due to (i) a broad spectra of monitored chemical species, meteorological, hydrological and other parameters, (ii) measurements in various environmental compartments and especially the atmosphere, (iii) provision of data suitable for conducting multidisciplinar research activities and (iv) participation in a number of international programmes and projects, i.e. ICOS (AS Křešín u Pacova), ACTRIS, ACCENT, CLRTAP/EMEP, GAW and ICP-IM (Košetice) and others. Finally, the collocated station has potential for a successful participation in the planned network of European superstations covering both climate and air quality issues, one of the key areas in the European Strategy Forum on Research Infrastructures (ESFRI) process. Acknowledgement: This work is supported by the CzechGlobe (CZ.1.05/1.1.00/02.0073) and CZ.1.07/2.4.00/31.0056 projects.
NASA Astrophysics Data System (ADS)
Deng, Lin
2016-05-01
This paper examines the seismic effects experienced by a solar receiver mounted on concrete towers with different fundamental periods. Ten concrete towers are modeled with the empty solar receiver structure and loaded solar receiver structure to examine the tower seismic effects on the solar receiver. The fundamental periods of the towers range from 0.22 seconds to 4.58 seconds, with heights ranging from 40.5 meters to 200 meters. Thirty earthquake ground motion records are used to investigate the responses of each of the combined receiver-on-tower models as well as the receiver-on-ground models by the STAAD Pro software using time history analyses. The earthquake ground motion records are chosen based on the ratio of the peak ground acceleration to the peak ground velocity, ranging from 0.29 g/m/s to 4.88 g/m/s. For each of the combined models, the base shear at the interface between the receiver and the concrete tower is compared with the base shear of the receiver-on-ground model, and the ratio of the two base shears represents the structure amplification factor. It is found that the peak mean plus one standard deviation value of the structure amplification factor matches well with equation 13.3-1 in ASCE 7-10 for the empty solar receiver structure. However, when the solar receiver structure is loaded with dead loads, the peak value is greatly suppressed, and using equation 13.3-1 in ASCE 7-10 will be overly conservative.
1985-05-01
Computer Engineering " Ohio University DTFAO1-83-C-10007. Athens. Ohio 45701 13 Typ o*# eoq endPan~d Cwvor 12 . 5pon**rAng Agate, Nome end Aililess...1 0.0833 1.S8x10-5 1.37x10-5 ft 30.48 0.3048 3.05x 10-4 12 1 1.89x00- 1.6400.4 S mi 160.900 1609 1.609 63360 5280 1 0.8688 nmi 185,200 1852 1.852...Clark Tower Data Normalized to 1000 feet 11 at 340* Azimuth Decay Factor - 1.95. 5 Machine A Clark Tower Data Normalized to 1000 feet 12 at 40* Azimuth
NASA Astrophysics Data System (ADS)
Teza, Giordano; Pesci, Arianna; Trevisani, Sebastiano
2014-05-01
Three regions of Northern Italy (Emilia Romagna, Veneto and Lombardy) were struck in May-June 2012 by a seismic sequence that included a moment magnitude 5.9 earthquake. Such a sequence caused significant damage to several historical buildings; in some cases complete structural collapse occurred. The 69-m high bell tower of Ficarolo (Rovigo province, Northern Italy) leans at a significant angle (~3° in the shaft). Because the combination of height and leaning angle is visually impressive, Ficarolo is also known as the 'Pisa of Polesine' (Polesine is the Venetian bank of the Po River), referring to the well-known 55-m high, 4° leaning tower of Pisa. A project aimed at studying the geometry of the tower, by means of terrestrial laser scanning (TLS), possible local seismic amplification and soil-structure interaction (SSI), by means of low-cost operational modal analysis (OMA) and geophysical measurements, began in early 2012, before the earthquake. In particular, the first series of data were taken in February 2012 (OMA) and April 2012 (TLS). The distance from Ficarolo of the epicenters of the six events with moment magnitude higher than 5.0 ranged from 9 km to 37 km. Several cracks appeared in the bell tower belfry and cusp. An inclinometer installed in 2003 showed that the base was unchanged, but the upper part of the shaft had moved by 2.5 cm after the main shock. No further displacements were detected as a result of the aftershocks. The repetition of the TLS and OMA surveys during and after the seismic sequence, together with infrared thermal imaging (IRT) measurements, allowed an evaluation of the changes caused by the earthquake. Two main results were obtained: (1) an estimate of earthquake induced damage to the Ficarolo's bell tower, which were relatively limited thanks to absence of SSI, and (2) it was demonstrated that fast measurements can be repeated during earthquake emergencies and that preventive measures can be carried out under reasonable time and budget constraints in high seismic hazard areas. The second point is particularly important from the viewpoint of cultural heritage management purposes.
NASA Astrophysics Data System (ADS)
Sixiang, Chen; Daopin, Chen; Ming, Zhang; Xiao, Huang; Jian, He; Zhijie, He
2017-05-01
Aimed at the actual situation of fish death in fish ponds near the power transmission line towers after the thunderstorm happened in Guangdong Province in China, this paper studied the influence of the ground current on fish in the pond. Firstly, This paper studied the current density of the fish without protection. On this basis, paper studied the horizontal pole with full-shielded, the vertical pole with half-shielded, the horizontal pole with extension three kinds of protective measures and effects. Finally an effective protection scheme was put forward according to the engineering practice. The results can provide some engineering guidance and quantitative basis for the design and modification of grounding devices when the tower is adjacent to the fish ponds in southern China.
2009-02-13
CAPE CANAVERAL, Fla. – On Launch Pad 39B at NASA's Kennedy Space Center in Florida, the 100-foot lightning mast has been raised to vertical. It will be lifted and installed on top of the third and final new lightning tower being erected around the pad. The new lightning protection system is being built for the Constellation Program and Ares/Orion launches. Each of the towers is 500 feet tall with an additional 100-foot fiberglass mast atop supporting a wire catenary system. This improved lightning protection system allows for the taller height of the Ares I rocket compared to the space shuttle. Pad 39B will be the site of the first Ares vehicle launch, including the Ares I-X test flight that is targeted for July 2009. Photo credit: NASA/Tim Jacobs
Lacome, Mathieu; Piscione, Julien; Hager, Jean-Philippe; Carling, Christopher
2016-09-01
To investigate the patterns and performance of substitutions in 18 international 15-a-side men's rugby union matches. A semiautomatic computerized time-motion system compiled 750 performance observations for 375 players (422 forwards, 328 backs). Running and technical-performance measures included total distance run, high-intensity running (>18.0 km/h), number of individual ball possessions and passes, percentage of passes completed, and number of attempted and percentage of successful tackles. A total of 184 substitutions (85.2%) were attributed to tactical and 32 (14.8%) to injury purposes respectively. The mean period for non-injury-purpose substitutions in backs (17.7%) occurred between 70 and 75 min, while forward substitutions peaked equally between 50-55 and 60-65 min (16.4%). Substitutes generally demonstrated improved running performance compared with both starter players who completed games and players whom they replaced (small differences, ES -0.2 to 0.5) in both forwards and backs over their entire time played. There was also a trend for better running performance in forward and back substitutes over their first 10 min of play compared with the final 10 min for replaced players (small to moderate differences, ES 0.3-0.6). Finally, running performance in both forward and back substitutes was generally lower (ES -0.1 to 0.3, unclear or small differences) over their entire 2nd-half time played compared with their first 10 min of play. The impact of substitutes on technical performance was generally considered unclear. This information provides practitioners with practical data relating to the physical and technical contributions of substitutions that subsequently could enable optimization of their impact on match play.
Schroeder, Liz; Patel, Nishma; Keeler, Michelle; Rocca-Ihenacho, Lucia; Macfarlane, Alison J
2017-02-01
to compare the economic costs of intrapartum maternity care in an inner city area for 'low risk' women opting to give birth in a freestanding midwifery unit compared with those who chose birth in hospital. micro-costing of health service resources used in the intrapartum care of mothers and their babies during the period between admission and discharge, data extracted from clinical notes. the Barkantine Birth Centre, a freestanding midwifery unit and the Royal London Hospital's consultant-led obstetric unit, both run by the former Barts and the London NHS Trust in Tower Hamlets, a deprived inner city borough in east London, England, 2007-2010. maternity records of 333 women who were resident in Tower Hamlets and who satisfied the Trust's eligibility criteria for using the Birth Centre. Of these, 167 women started their intrapartum care at the Birth Centre and 166 started care at the Royal London Hospital. women who planned their birth at the Birth Centre experienced continuous intrapartum midwifery care, higher rates of spontaneous vaginal delivery, greater use of a birth pool, lower rates of epidural use, higher rates of established breastfeeding and a longer post-natal stay, compared with those who planned for care in the hospital. The total average cost per mother-baby dyad for care where mothers started their intrapartum care at the Birth Centre was £1296.23, approximately £850 per patient less than the average cost per mother and baby who received all their care at the Royal London Hospital. These costs reflect intrapartum throughput using bottom up costing per patient, from admission to discharge, including transfer, but excluding occupancy rates and the related running costs of the units. the study showed that intrapartum throughput in the Birth Centre could be considered cost-minimising when compared to hospital. Modelling the financial viability of midwifery units at a local level is important because it can inform the appropriate provision of these services. This finding from this study contribute a local perspective and thus further weight to the evidence from the Birthplace Programme in support of freestanding midwifery unit care for women without obstetric complications. Copyright © 2016. Published by Elsevier Ltd.
Wind turbine tower for storing hydrogen and energy
Fingersh, Lee Jay [Westminster, CO
2008-12-30
A wind turbine tower assembly for storing compressed gas such as hydrogen. The tower assembly includes a wind turbine having a rotor, a generator driven by the rotor, and a nacelle housing the generator. The tower assembly includes a foundation and a tubular tower with one end mounted to the foundation and another end attached to the nacelle. The tower includes an in-tower storage configured for storing a pressurized gas and defined at least in part by inner surfaces of the tower wall. In one embodiment, the tower wall is steel and has a circular cross section. The in-tower storage may be defined by first and second end caps welded to the inner surface of the tower wall or by an end cap near the top of the tower and by a sealing element attached to the tower wall adjacent the foundation, with the sealing element abutting the foundation.
Benowitz, Isaac; Fitzhenry, Robert; Boyd, Christopher; Dickinson, Michelle; Levy, Michael; Lin, Ying; Nazarian, Elizabeth; Ostrowsky, Belinda; Passaretti, Teresa; Rakeman, Jennifer; Saylors, Amy; Shamoonian, Elena; Smith, Terry-Ann; Balter, Sharon
2018-01-01
We investigated an outbreak of eight Legionnaires’ disease cases among persons living in an urban residential community of 60,000 people. Possible environmental sources included two active cooling towers (air-conditioning units for large buildings) <1 km from patient residences, a market misting system, a community-wide water system used for heating and cooling, and potable water. To support a timely public health response, we used real-time polymerase chain reaction (PCR) to identify Legionella DNA in environmental samples within hours of specimen collection. We detected L. pneumophila serogroup 1 DNA only at a power plant cooling tower, supporting the decision to order remediation before culture results were available. An isolate from a power plant cooling tower sample was indistinguishable from a patient isolate by pulsed-field gel electrophoresis, suggesting the cooling tower was the outbreak source. PCR results were available <1 day after sample collection, and culture results were available as early as 5 days after plating. PCR is a valuable tool for identifying Legionella DNA in environmental samples in outbreak settings. PMID:29780175
Legionnaires' disease bacteria in power plant cooling systems: downtime report. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tyndall, R.L.; Solomon, J.A.; Christensen, S.W.
1985-11-01
Legionnaires' disease bacteria (Legionella) are a normal part of the aquatic community that, when aerosolized, can be pathogenic to man. The downtime study was designed to determine the degree to which Legionella populations are aerosolized during cleaning and maintenance operations in a closed-cycle steam-electric power plant. Both high-volume and impinger air samples were collected prior to and during downtime operations. Emphasis was placed on sampling inside or adjacent to water boxes, condensers, and cooling towers. Control air samples were taken upwind from the plant site. Water and sludge samples were also collected at various locations. In the laboratory, the concentrationsmore » of Legionella were determined using the direct fluorescent antibody method. All positive air samples, and other selected air samples, were injected into guinea pigs to detect infectious Legionella. Legionella could be detected in only 12 of the 127 air samples collected. These were predominantly L. pneumophila, serogroups 1-6. In contrast to the air samples, most of the water and sludge samples were positive for Legionella, again predominantly L. pneumophila, serogroups 1-6. The highest Legionella concentrations were found in sludge samples associated with condenser tube cleaning. Among the water samples, the highest Legionella concentrations were found in cooling towers, immediately after the tower basins were cleaned and refilled, and in condenser tubes. Two of the three cooling tower water samples collected prior to downtime operations were infectious for guinea pigs. 16 refs., 4 figs., 11 tabs.« less
The re-emergence of the minimal running shoe.
Davis, Irene S
2014-10-01
The running shoe has gone through significant changes since its inception. The purpose of this paper is to review these changes, the majority of which have occurred over the past 50 years. Running footwear began as very minimal, then evolved to become highly cushioned and supportive. However, over the past 5 years, there has been a reversal of this trend, with runners seeking more minimal shoes that allow their feet more natural motion. This abrupt shift toward footwear without cushioning and support has led to reports of injuries associated with minimal footwear. In response to this, the running footwear industry shifted again toward the development of lightweight, partial minimal shoes that offer some support and cushioning. In this paper, studies comparing the mechanics between running in minimal, partial minimal, and traditional shoes are reviewed. The implications for injuries in all 3 conditions are examined. The use of minimal footwear in other populations besides runners is discussed. Finally, areas for future research into minimal footwear are suggested.
ERIC Educational Resources Information Center
Greenslade, Thomas B., Jr.
2010-01-01
The finale of the weekly physics department seminar series at my college is my annual demonstration lecture. Normally, the front of the room is filled with apparatus, but in May 2008 I had only a giant kaleidoscope and a leaning tower of Pisa (Fig. 1) on display. Instead, there was a pile of overhead projector transparencies that showed examples…
Research Turbine Leaves Legacy in Its Wake | News | NREL
110. Two 340-foot cranes were needed to install the larger, 175-foot blades optimized for intermediate depending, to remove the blades, then the nacelle, and finally the tower, section by section. "Site operating the turbine, but also performing complex procedures-like changing out blades that weigh more than
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-26
... has not valued CXS's river water using the SV for municipal water.\\14\\ \\14\\ See Issues and Decision... the Preliminary Determination, the Department found that Colombia, Indonesia, Peru, South Africa... River Water Using the SV for Municipal Water Comment 12: Whether the Department Should Exclude Stainless...
1965-03-01
The hydrogen-powered second stage is being lowered into place during the final phase of fabrication of the Saturn V moon rocket at North American's Seal Beach, California facility. The towering 363-foot Saturn V was a multi-stage, multi-engine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-27
... E Airspace; State College, PA AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final rule... College, PA, to accommodate a new air traffic control tower at University Park Airport. The FAA is taking this action to enhance the safety and management of instrument Flight Rules (IFR) operations. DATES...
NASA Astrophysics Data System (ADS)
Ma, Libin; Ren, Jianxing
2018-01-01
Large capacity and super large capacity thermal power is becoming the main force of energy and power industry in our country. The performance of cooling tower is related to the water temperature of circulating water, which has an important influence on the efficiency of power plant. The natural draft counter flow wet cooling tower is the most widely used cooling tower type at present, and the high cooling tower is a new cooling tower based on the natural ventilation counter flow wet cooling tower. In this paper, for high cooling tower, the application background of high cooling tower is briefly explained, and then the structure principle of conventional cooling tower and high cooling tower are introduced, and the difference between them is simply compared. Then, the influence of crosswind on cooling performance of high cooling tower under different wind speeds is introduced in detail. Through analysis and research, wind speed, wind cooling had little impact on the performance of high cooling tower; wind velocity, wind will destroy the tower inside and outside air flow, reducing the cooling performance of high cooling tower; Wind speed, high cooling performance of cooling tower has increased, but still lower than the wind speed.
Li, Lijie; Qin, Tian; Li, Yun; Zhou, Haijian; Song, Hongmei; Ren, Hongyu; Li, Liping; Li, Yongguang; Zhao, Dong
2015-01-01
Cooling towers are a source of Legionnaires’ disease. It is important from a public health perspective to survey industrial cooling towers for the presence of Legionella. Prospective surveillance of the extent of Legionella pollution was conducted at factories in Shijiazhuang, China between March 2011 and September 2012. Overall, 35.7% of 255 industrial cooling tower water samples showed Legionella-positive, and their concentrations ranged from 100 Colony-Forming Units (CFU)/liter to 88,000 CFU/liter, with an average concentration of 9100 CFU/liter. A total of 121 isolates were obtained. All isolates were L. pneumophila, and the isolated serogroups included serogroups 1 (68 isolates, 56.2%), 6 (25, 20.7%), 5 (12, 9.9%), 8 (8, 6.6%), 3 (6, 5.0%) and 9 (2, 1.6%). All 121 isolates were analyzed by pulsed-field gel electrophoresis (PFGE) and 64 different patterns were obtained. All 121 isolates were analyzed sequence-based typing (SBT), a full 7-allele profile was obtained from 117 isolates. One hundred and seventeen isolates were divided into 49 sequence types. Two virulence genes, lvh and rtxA, are analyzed by polymerase chain reaction (PCR). 92.6% (112/121) and 98.3% (119/121) isolates carried lvh and rtxA respectively and 90.9% (110/121) of tested isolates carried both genes. Our results demonstrated high prevalence and genetic polymorphism of L. pneumophila in industrial cooling tower environments in Shijiazhang, China, and the SBT and virulence gene PCR results suggested that the isolates were pathogenic. Improved control and prevention strategies are urgently needed. PMID:26473896
Li, Lijie; Qin, Tian; Li, Yun; Zhou, Haijian; Song, Hongmei; Ren, Hongyu; Li, Liping; Li, Yongguang; Zhao, Dong
2015-10-12
Cooling towers are a source of Legionnaires' disease. It is important from a public health perspective to survey industrial cooling towers for the presence of Legionella. Prospective surveillance of the extent of Legionella pollution was conducted at factories in Shijiazhuang, China between March 2011 and September 2012. Overall, 35.7% of 255 industrial cooling tower water samples showed Legionella-positive, and their concentrations ranged from 100 Colony-Forming Units (CFU)/liter to 88,000 CFU/liter, with an average concentration of 9100 CFU/liter. A total of 121 isolates were obtained. All isolates were L. pneumophila, and the isolated serogroups included serogroups 1 (68 isolates, 56.2%), 6 (25, 20.7%), 5 (12, 9.9%), 8 (8, 6.6%), 3 (6, 5.0%) and 9 (2, 1.6%). All 121 isolates were analyzed by pulsed-field gel electrophoresis (PFGE) and 64 different patterns were obtained. All 121 isolates were analyzed sequence-based typing (SBT), a full 7-allele profile was obtained from 117 isolates. One hundred and seventeen isolates were divided into 49 sequence types. Two virulence genes, lvh and rtxA, are analyzed by polymerase chain reaction (PCR). 92.6% (112/121) and 98.3% (119/121) isolates carried lvh and rtxA respectively and 90.9% (110/121) of tested isolates carried both genes. Our results demonstrated high prevalence and genetic polymorphism of L. pneumophila in industrial cooling tower environments in Shijiazhang, China, and the SBT and virulence gene PCR results suggested that the isolates were pathogenic. Improved control and prevention strategies are urgently needed.
Tracking and shape errors measurement of concentrating heliostats
NASA Astrophysics Data System (ADS)
Coquand, Mathieu; Caliot, Cyril; Hénault, François
2017-09-01
In solar tower power plants, factors such as tracking accuracy, facets misalignment and surface shape errors of concentrating heliostats are of prime importance on the efficiency of the system. At industrial scale, one critical issue is the time and effort required to adjust the different mirrors of the faceted heliostats, which could take several months using current techniques. Thus, methods enabling quick adjustment of a field with a huge number of heliostats are essential for the rise of solar tower technology. In this communication is described a new method for heliostat characterization that makes use of four cameras located near the solar receiver and simultaneously recording images of the sun reflected by the optical surfaces. From knowledge of a measured sun profile, data processing of the acquired images allows reconstructing the slope and shape errors of the heliostats, including tracking and canting errors. The mathematical basis of this shape reconstruction process is explained comprehensively. Numerical simulations demonstrate that the measurement accuracy of this "backward-gazing method" is compliant with the requirements of solar concentrating optics. Finally, we present our first experimental results obtained at the THEMIS experimental solar tower plant in Targasonne, France.
NASA Astrophysics Data System (ADS)
Ayub, F.; Akhand, S.; Khan, A. S.; Saklayen, G.
2018-05-01
In our studies we focused on area of sourcing, converting and delivering sustainable energy, concentrating at the potential role of solar power. Power generation through a solar updraft tower (SUT) has been a promising approach for sustainable generation of renewable energy. Developing nations are faced with many challenges. Conventional sources are insufficient to meet the increasing demand of a developing, industrious nation (e.g. Bangladesh). Our project aims in reducing electricity crisis and forming a solution for our country, Bangladesh. The electricity generated can be supplied to the national grid. This will mean reduced cost for the government in the long run and also allow the government to reduce its dependency on costly and unsustainable fossil fuel. This cost reduction benefit can be passed on to the public as reduced energy cost or preferably through nationwide energy infrastructure development. This technology will not only help with the energy concern of Bangladesh but also will help to improve the situations of other developing countries alike Bangladesh. All in all implementing this technology will pave the way towards a better world and form a part of an integrated ecosystem of sustainable energy technology.
Aerodynamic Testing of the Orion Launch Abort Tower Separation with Jettison Motor Jet Interactions
NASA Technical Reports Server (NTRS)
Rhode, Matthew N.; Chan, David T.; Niskey, Charles J.; Wilson, Thomas M.
2011-01-01
The aerodynamic database for the Orion Launch Abort System (LAS) was developed largely from wind tunnel tests involving powered jet simulations of the rocket exhaust plumes, supported by computational fluid dynamics (CFD) simulations. The LAS contains three solid rocket motors used in various phases of an abort to provide propulsion, steering, and Launch Abort Tower (LAT) jettison from the Crew Module (CM). This paper describes a pair of wind tunnel experiments performed at transonic and supersonic speeds to determine the aerodynamic effects due to proximity and jet interactions during LAT jettison from the CM at the end of an abort. The tests were run using two different scale models at angles of attack from 150deg to 200deg , sideslip angles from -10deg to +10deg , and a range of powered thrust levels from the jettison motors to match various jet simulation parameters with flight values. Separation movements between the CM and LAT included axial and vertical translations as well as relative pitch angle between the two bodies. The paper details aspects of the model design, nozzle scaling methodology, instrumentation, testing procedures, and data reduction. Sample data are shown to highlight trends seen in the results.
Modeling and Simulation of Offshore Wind Power Platform for 5 MW Baseline NREL Turbine.
Roni Sahroni, Taufik
2015-01-01
This paper presents the modeling and simulation of offshore wind power platform for oil and gas companies. Wind energy has become the fastest growing renewable energy in the world and major gains in terms of energy generation are achievable when turbines are moved offshore. The objective of this project is to propose new design of an offshore wind power platform. Offshore wind turbine (OWT) is composed of three main structures comprising the rotor/blades, the tower nacelle, and the supporting structure. The modeling analysis was focused on the nacelle and supporting structure. The completed final design was analyzed using finite element modeling tool ANSYS to obtain the structure's response towards loading conditions and to ensure it complies with guidelines laid out by classification authority Det Norske Veritas. As a result, a new model of the offshore wind power platform for 5 MW Baseline NREL turbine was proposed.
Modeling and Simulation of Offshore Wind Power Platform for 5 MW Baseline NREL Turbine
Roni Sahroni, Taufik
2015-01-01
This paper presents the modeling and simulation of offshore wind power platform for oil and gas companies. Wind energy has become the fastest growing renewable energy in the world and major gains in terms of energy generation are achievable when turbines are moved offshore. The objective of this project is to propose new design of an offshore wind power platform. Offshore wind turbine (OWT) is composed of three main structures comprising the rotor/blades, the tower nacelle, and the supporting structure. The modeling analysis was focused on the nacelle and supporting structure. The completed final design was analyzed using finite element modeling tool ANSYS to obtain the structure's response towards loading conditions and to ensure it complies with guidelines laid out by classification authority Det Norske Veritas. As a result, a new model of the offshore wind power platform for 5 MW Baseline NREL turbine was proposed. PMID:26550605
Evaluation of NASA's Carbon Monitoring System (CMS) Flux Pilot: Terrestrial CO2 Fluxes
NASA Astrophysics Data System (ADS)
Fisher, J. B.; Polhamus, A.; Bowman, K. W.; Collatz, G. J.; Potter, C. S.; Lee, M.; Liu, J.; Jung, M.; Reichstein, M.
2011-12-01
NASA's Carbon Monitoring System (CMS) flux pilot project combines NASA's Earth System models in land, ocean and atmosphere to track surface CO2 fluxes. The system is constrained by atmospheric measurements of XCO2 from the Japanese GOSAT satellite, giving a "big picture" view of total CO2 in Earth's atmosphere. Combining two land models (CASA-Ames and CASA-GFED), two ocean models (ECCO2 and NOBM) and two atmospheric chemistry and inversion models (GEOS-5 and GEOS-Chem), the system brings together the stand-alone component models of the Earth System, all of which are run diagnostically constrained by a multitude of other remotely sensed data. Here, we evaluate the biospheric land surface CO2 fluxes (i.e., net ecosystem exchange, NEE) as estimated from the atmospheric flux inversion. We compare against the prior bottom-up estimates (e.g., the CASA models) as well. Our evaluation dataset is the independently derived global wall-to-wall MPI-BGC product, which uses a machine learning algorithm and model tree ensemble to "scale-up" a network of in situ CO2 flux measurements from 253 globally-distributed sites in the FLUXNET network. The measurements are based on the eddy covariance method, which uses observations of co-varying fluxes of CO2 (and water and energy) from instruments on towers extending above ecosystem canopies; the towers integrate fluxes over large spatial areas (~1 km2). We present global maps of CO2 fluxes and differences between products, summaries of fluxes by TRANSCOM region, country, latitude, and biome type, and assess the time series, including timing of minimum and maximum fluxes. This evaluation shows both where the CMS is performing well, and where improvements should be directed in further work.
The Resilient Infrastructure Initiative
Clifford, Megan
2016-10-01
Infrastructure is, by design, largely unnoticed until it breaks down and services fail. This includes water supplies, gas pipelines, bridges and dams, phone lines and cell towers, roads and culverts, railways, and the electric grid—all of the complex systems that keep our societies and economies running. Climate change, population growth, increased urbanization, system aging, and outdated design standards stress existing infrastructure and its ability to satisfy the rapidly changing demands from users. Here, the resilience of both physical and cyber infrastructure systems, however, is critical to a community as it prepares for, responds to, and recovers from a disaster, whethermore » natural or man-made.« less
Legionella in Puerto Rico cooling towers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Negron-Alviro, A.; Perez-Suarez, I.; Hazen, T.C.
1988-12-31
Water samples from air conditioning cooling towers receiving different treatment protocols on five large municipal buildings in San Juan, Puerto Rico were assayed for various species and serogroups of Legionella spp. using direct immunofluorescence. Several water quality parameters were also measured with each sample. Guinea pigs were inoculated with water samples to confirm pathogenicity and recover viable organisms. Legionella pneumophila (1-6), L. bozemanii, L. micdadei, L. dumoffii, and L. gormanii were observed in at least one of the cooling towers. L. pneumophila was the most abundant species, reaching 10{sup 5} cells/ml, within the range that is considered potentially pathogenic tomore » humans. A significantly higher density of L. pneumophila was observed in the cooling tower water that was not being treated with biocides. Percent respiration (INT) and total cell activity (AODC), were inversely correlated with bacterial density. This study demonstrates that Legionella spp. are present in tropical air-conditioning cooling systems, and without continuous biocide treatment may reach densities that present a health risk.« less
A simplified model of a mechanical cooling tower with both a fill pack and a coil
NASA Astrophysics Data System (ADS)
Van Riet, Freek; Steenackers, Gunther; Verhaert, Ivan
2017-11-01
Cooling accounts for a large amount of the global primary energy consumption in buildings and industrial processes. A substantial part of this cooling demand is produced by mechanical cooling towers. Simulations benefit the sizing and integration of cooling towers in overall cooling networks. However, for these simulations fast-to-calculate and easy-to-parametrize models are required. In this paper, a new model is developed for a mechanical draught cooling tower with both a cooling coil and a fill pack. The model needs manufacturers' performance data at only three operational states (at varying air and water flow rates) to be parametrized. The model predicts the cooled, outgoing water temperature. These predictions were compared with experimental data for a wide range of operational states. The model was able to predict the temperature with a maximum absolute error of 0.59°C. The relative error of cooling capacity was mostly between ±5%.
NASA Astrophysics Data System (ADS)
Kanli, A. I.; Taller, G.; Nagy, P.; Tildy, P.; Pronay, Z.; Toros, E.
2013-12-01
The Fire-Tower which is located in the main square at the hearth of Sopron is the symbol of the city. The museum of Sopron exists in the Storno-house west from the tower. The new city hall stands next to the tower to the east. Funds are from the roman age while the tower was first mentioned in writing in 1409. In 1676, it was burned down to the ground, but re-constructed. In 1894, the old City Hall was deconstucted, but the tower became unstable. István Kiss and Frigyes Schulek saved it by the walling up of the gate. In the year 1928, the scuptures of the main gate which symbolizes the fidelity of the town was sculpted by Zsigmond Kisfaludy Strobl. The old building was deconstructed from its west side, a new concrate museum was built in 1970. After years, important renovation and reinforcement studies had to be needed. For this aim, during the renovation and reinforcement studies, GPR and Seismic based non-destructive geophysical surveys were carried out before and after cement injection to observe the changes of the wall conditions of the historical tower located in Sopron-Hungary for understanding the success of the reinforcements studies. In the GPR survey, 400 MHz and 900 MHz antennas were used. The space between each profiles were taken as 0.5 m for 400 MHz and 0.25m for 900 MHz respectively. After the injection process, reflections from the fractured and porous zones were weakened imaged clearly by GPR data and significant rise of the p-wave velocities were observed.
NASA Astrophysics Data System (ADS)
Chen, Z.; Griffis, T. J.; Lee, X.; Fu, C.; Dlugokencky, E. J.; Andrews, A. E.
2017-12-01
Mitigation of nitrous oxide (N2O) emissions requires a sound understanding of N2O production processes and a robust estimate of N2O budgets. It is critical to understand how emissions vary spatially and temporally, and how they are likely to change given future climate and land management decisions. To address these challenges we have coupled two models including WRF-Chem version 3.8.1 and CLM-GBC-CROP version 4.5 to simulate retrospective and future N2O emissions for the US Corn Belt. Using 7 years (2010-2016) of N2O mixing ratio data from 6 tall tower sites within the US Midwest, we ran the coupled model at a spatial resolution of 0.125o× 0.125o and tested and optimized the simulation of N2O emissions at hourly, seasonal, and inter-annual timescales. Our preliminary results indicate:1) The simulated tall tower mixing ratios for 6 tall towers were all significantly higher than the observations in the growing seasons, indicating a high bias of N2O emissions when using the default N2O production mechanisms in CLM. 2) Following the optimization of N2O production in CLM, the simulated tall tower mixing ratios were strongly correlated with the KCMP and WBI towers, and had moderate correlation with the BAO tower. Overall, the absolute biases in mixing ratios were relatively small. Our next step is to examine 7 years of simulations to assess the spatiotemporal variations of direct and indirect emissions within the US Corn Belt to help identify potential N2O hotspots and hot moments.
NASA Technical Reports Server (NTRS)
Smith, Penny A. Morris
1999-01-01
Archean aged rocks from the Pilbara Block area of western Australia (Warrawoona Group, Towers Formation, -3.3-3.5 Ga) contain microfossils that are composed of various sizes of spheres and filaments. The first descriptions of these microfossils were published in the late 1970's (Dunlop, 1978; Dunlop, et. al., 1978). The authenticity of the microfossils is well established. The small size of the microfossils prevents isotope dating, at least with the present technology. Microbiologists, however, have established guidelines to determine the authenticity of the Archean aged organic remains (Schopf, Walter, 1992).
1988-07-29
Departure List. T1.1.4.13 RESEQUENCE FOE MANUALLY 3.7.2.2.1.1.2.2-00 ARRIVAL LIST 457 3.7.2.2.1,1.2.2-11 b. Ordering - In manual ordering , the 457 a...3.7.2.2.1.1.2.3-12 b. Ordering - In manual ordering , the 457 controller shall have the capability to put a new FOE in the appropriate place in a sublist...3.7.2.2.1.1.2.2-00 ARRIVAL LIST 457 3.7.2.2.1.1.2.2-11 b. Ordering - In manual ordering , the 457 controller snall have the capability to put a new FOE in
Diboson excess and Z‧-predictions via left-right nonlinear Higgs
NASA Astrophysics Data System (ADS)
Shu, Jing; Yepes, Juan
2016-12-01
The excess events reported by the ATLAS collaboration in the WZ-final state, and by the CMS collaboration in the e+e-jj, Wh and jj-final states, may be induced by the decays of a heavy boson W‧ in the 1.8-2 TeV mass range, here modeled via the larger local group SU(2)L × SU(2)R × U(1)B-L in a nonlinear dynamical Higgs scenario. The W‧-production cross-section at the 13 TeV LHC is around 700-1200 fb. This framework also predicts a heavy Z‧ boson with a mass of 2.5-4 TeV, and some decay channels testable in the LHC Run II. We determine the cross-section times branching fractions for the dijet, dilepton and top-pair Z‧-decay channels at the 13 TeV LHC around 2.3, 7.1, 70.2 fb, respectively, for MZ‧ = 2.5 TeV, while one/two orders of magnitude smaller for the dijet/dilepton and top-pair modes at MZ‧ = 4 TeV. Nonzero contributions from the effective operators, and the underlying Higgs sector of the model, will induce sizeable enhancement in the W+W- and Zh-final states that could be probed in the future LHC Run II.
Background and system description of the Mod 1 wind turbine generator
NASA Technical Reports Server (NTRS)
Ernst, E. H.
1978-01-01
The Mod-1 wind turbine considered is a large utility-class machine, operating in the high wind regime, which has the potential for generation of utility grade power at costs competitive with other alternative energy sources. A Mod-1 wind turbine generator (WTG) description is presented, taking into account the two variable-pitch steel blades of the rotor, the drive train, power generation/control, the Nacelle structure, and the yaw drive. The major surface elements of the WTG are the ground enclosure, the back-up battery system, the step-up transformer, elements of the data system, cabling, area lighting, and tower foundation. The final system weight (rotor, Nacelle, and tower) is expected to be about 650,000 pounds. The WTG will be capable of delivering 1800 kW to the utility grid in a wind-speed above 25 mph.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-26
... of the solar field. A heat transfer fluid is heated as it passes through the receiver tower and is... Statement for the Tonopah Solar Energy Crescent Dunes Solar Energy Project, Nye County, NV AGENCY: Bureau of... Statement (EIS) for the Crescent Dunes Solar Energy Project, Nye County, Nevada, and by this notice is...
DETAIL VIEW OF AERIAL TRAM SUPPORT TOWER SIX WITH TOWERS ...
DETAIL VIEW OF AERIAL TRAM SUPPORT TOWER SIX WITH TOWERS SEVEN,EIGHT, NINE, TEN, AND BREAK OVER TOWER IN DISTANCE, LOOKING NORTH. TOWER SIX IS THE LAST BEFORE A DEEP CHASM, AS IS SEEN BY THE DISTANCE BETWEEN TOWERS SIX AND SEVEN. SEE CA-291-48 (CT) FOR IDENTICAL COLOR TRANSPARENCY. - Keane Wonder Mine, Park Route 4 (Daylight Pass Cutoff), Death Valley Junction, Inyo County, CA
DETAIL VIEW OF AERIAL TRAM SUPPORT TOWER SIX WITH TOWERS ...
DETAIL VIEW OF AERIAL TRAM SUPPORT TOWER SIX WITH TOWERS SEVEN, EIGHT, NINE, TEN, AND BREAK OVER TOWER IN DISTANCE, LOOKING NORTH. TOWER SIX IS THE LAST BEFORE A DEEP CHASM, AS IS SEEN BY THE DISTANCE BETWEEN TOWERS SIX AND SEVEN. SEE CA-291-21 FOR IDENTICAL B&W NEGATIVE. - Keane Wonder Mine, Park Route 4 (Daylight Pass Cutoff), Death Valley Junction, Inyo County, CA
Hartman, Esther; Smith, Joanne; Houwen, Suzanne; Visscher, Chris
2017-05-01
Children with intellectual disabilities (ID) or borderline intellectual disabilities (BIF) often demonstrate impairments in executive functioning (EF). Studies in typically developing children show that aerobic fitness (AF) is positively related with EF. Skill-related physical fitness (SF) might, however, be a stronger predictor of EF than AF, as cognitive challenges are inherent in application of these skills. In this study, AF and SF were examined simultaneously in relationship with domains of EF in children with ID or BIF. Seventy-three children (age range 8-11; 51 boys) with ID (IQ range 56-79) or BIF (IQ range 71-79) were measured annually over a period of 4 years on AF (20-m endurance shuttle run test) and SF (plate tapping and 10×5m run). EF was measured with the Stroop Color-Word test (inhibition), Trailmaking and Fluency test (cognitive flexibility), Self-ordered pointing task (working memory) and the Tower of London (planning). Multilevel models showed that SF was significantly associated with inhibition and both measures of cognitive flexibility, but in the same models no significant associations between AF and EF were found. In addition, age was significantly related to working memory and cognitive flexibility, favouring the older children. In children with ID or BIF, SF is of greater importance than AF in relationship with core domains of EF. Copyright © 2017 Elsevier Ltd. All rights reserved.
Fischer, Marc L.; Parazoo, Nicholas; Brophy, Kieran; ...
2017-03-09
Here, we report simulation experiments estimating the uncertainties in California regional fossil fuel and biosphere CO 2 exchanges that might be obtained by using an atmospheric inverse modeling system driven by the combination of ground-based observations of radiocarbon and total CO 2, together with column-mean CO 2 observations from NASA's Orbiting Carbon Observatory (OCO-2). The work includes an initial examination of statistical uncertainties in prior models for CO 2 exchange, in radiocarbon-based fossil fuel CO 2 measurements, in OCO-2 measurements, and in a regional atmospheric transport modeling system. Using these nominal assumptions for measurement and model uncertainties, we find thatmore » flask measurements of radiocarbon and total CO 2 at 10 towers can be used to distinguish between different fossil fuel emission data products for major urban regions of California. We then show that the combination of flask and OCO-2 observations yields posterior uncertainties in monthly-mean fossil fuel emissions of ~5–10%, levels likely useful for policy relevant evaluation of bottom-up fossil fuel emission estimates. Similarly, we find that inversions yield uncertainties in monthly biosphere CO 2 exchange of ~6%–12%, depending on season, providing useful information on net carbon uptake in California's forests and agricultural lands. Finally, initial sensitivity analysis suggests that obtaining the above results requires control of systematic biases below approximately 0.5 ppm, placing requirements on accuracy of the atmospheric measurements, background subtraction, and atmospheric transport modeling.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fischer, Marc L.; Parazoo, Nicholas; Brophy, Kieran
Here, we report simulation experiments estimating the uncertainties in California regional fossil fuel and biosphere CO 2 exchanges that might be obtained by using an atmospheric inverse modeling system driven by the combination of ground-based observations of radiocarbon and total CO 2, together with column-mean CO 2 observations from NASA's Orbiting Carbon Observatory (OCO-2). The work includes an initial examination of statistical uncertainties in prior models for CO 2 exchange, in radiocarbon-based fossil fuel CO 2 measurements, in OCO-2 measurements, and in a regional atmospheric transport modeling system. Using these nominal assumptions for measurement and model uncertainties, we find thatmore » flask measurements of radiocarbon and total CO 2 at 10 towers can be used to distinguish between different fossil fuel emission data products for major urban regions of California. We then show that the combination of flask and OCO-2 observations yields posterior uncertainties in monthly-mean fossil fuel emissions of ~5–10%, levels likely useful for policy relevant evaluation of bottom-up fossil fuel emission estimates. Similarly, we find that inversions yield uncertainties in monthly biosphere CO 2 exchange of ~6%–12%, depending on season, providing useful information on net carbon uptake in California's forests and agricultural lands. Finally, initial sensitivity analysis suggests that obtaining the above results requires control of systematic biases below approximately 0.5 ppm, placing requirements on accuracy of the atmospheric measurements, background subtraction, and atmospheric transport modeling.« less
Simulation of π 0-γ separation study for proposed CMS forward electromagnetic calorimeter
Roy, Ashim; Jain, Shilpi; Banerjee, Sunanda; ...
2016-11-11
The Forward Electromagnetic Calorimeter of the CMS detector is going to be upgraded in the high luminosity running as the energy of the present Electromagnetic Calorimeter (PbWO4) will degrade in the high luminosity (luminosity 10 34 cm -2 s -1) running due to extensive radiation (hadron flux 10 13 neutrons cm, -2). Shashlik Electromagnetic Calorimeter which consists of alternate layers of 1.5 mm LYSO(Ce) crystal plates and 2.5 mm Tungsten absorbers, was a proposal for high luminosity running. One of the performance points for any electromagnetic calorimeter is the ability to separate π 0 s from true photons, since finalmore » states with photons are a clean and one of the most important final states in proton-proton collisions at the LHC. As a result, the objective of this project is to study the possibility of π 0 and γ separation in the Shashlik detector using Multivariate Analysis (MVA) technique.« less
Simulation of π 0-γ separation study for proposed CMS forward electromagnetic calorimeter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roy, Ashim; Jain, Shilpi; Banerjee, Sunanda
The Forward Electromagnetic Calorimeter of the CMS detector is going to be upgraded in the high luminosity running as the energy of the present Electromagnetic Calorimeter (PbWO4) will degrade in the high luminosity (luminosity 10 34 cm -2 s -1) running due to extensive radiation (hadron flux 10 13 neutrons cm, -2). Shashlik Electromagnetic Calorimeter which consists of alternate layers of 1.5 mm LYSO(Ce) crystal plates and 2.5 mm Tungsten absorbers, was a proposal for high luminosity running. One of the performance points for any electromagnetic calorimeter is the ability to separate π 0 s from true photons, since finalmore » states with photons are a clean and one of the most important final states in proton-proton collisions at the LHC. As a result, the objective of this project is to study the possibility of π 0 and γ separation in the Shashlik detector using Multivariate Analysis (MVA) technique.« less
Seismic wave propagation modeling
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, E.M.; Olsen, K.B.
1998-12-31
This is the final report of a one-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). A hybrid, finite-difference technique was developed for modeling nonlinear soil amplification from three-dimensional, finite-fault radiation patters for earthquakes in arbitrary earth models. The method was applied to the 17 January 1994 Northridge earthquake. Particle velocities were computed on a plane at 5-km depth, immediately above the causative fault. Time-series of the strike-perpendicular, lateral velocities then were propagated vertically in a soil column typical of the San Fernando Valley. Suitable material models were adapted from a suite used tomore » model ground motions at the US Nevada Test Site. The effects of nonlinearity reduced relative spectral amplitudes by about 40% at frequencies above 1.5 Hz but only by 10% at lower frequencies. Runs made with source-depth amplitudes increased by a factor of two showed relative amplitudes above 1.5 Hz reduced by a total of 70% above 1.5 Hz and 20% at lower frequencies. Runs made with elastic-plastic material models showed similar behavior to runs made with Masing-Rule models.« less
System calibration of the 1.4 GHz and 5 GHz radiometers for soil moisture remote sensing
NASA Technical Reports Server (NTRS)
Wang, J.; Shiue, J.; Gould, W.; Fuchs, J.; Hirschmann, E.; Glazar, W.
1980-01-01
Two microwave radiometers at the frequencies of 1.4 GHz and 5 GHz were mounted on a mobile tower and used for a remote sensing of soil moisture experiment at a Beltsville Agriculture Research Center test site. The experiment was performed in October 1979 over both bare field and fields covered with grass, soybean, and corn. The calibration procedure for the radiometer systems which forms the basis of obtaining the final radiometric data product is described. It is estimated from the calibration results that the accuracy of the 1.4 GHz radiometric measurements is about + or - 3 K. The measured 5 GHz brightness temperatures over bare fields with moisture content greater than 10 percent by dry weight are about 8 K lower than those taken simultaneously at 1.4 GHz. This could be due to either (1) a 5 GHz antenna side lobe seeing the cold brightness of the sky, or (2) the thermal microwave emission from a soil being less sensitive to surface roughness at 5 GHz than at 1.4 GHz.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Celis, Gerardo; Mauritz, Marguerite; Bracho, Rosvel
Current and future warming of high-latitude ecosystems will play an important role in climate change through feedbacks to the global carbon cycle. This study compares 6 years of CO 2 flux measurements in moist acidic tundra using autochambers and eddy covariance (Tower) approaches. Here, we found that the tundra was an annual source of CO 2 to the atmosphere as indicated by net ecosystem exchange using both methods with a combined mean of 105 ± 17 g CO 2 C m-2 y-1 across methods and years (Tower 87 ± 17 and Autochamber 123 ± 14). Furthermore, the difference between methodsmore » was largest early in the observation period, with Autochambers indicated a greater CO 2 source to the atmosphere. This discrepancy diminished through time, and in the final year the Autochambers measured a greater sink strength than tower. Active layer thickness was a significant driver of net ecosystem carbon exchange, gross ecosystem primary productivity, and Reco and could account for differences between Autochamber and Tower. The stronger source initially attributed lower summer season gross primary production (GPP) during the first 3 years, coupled with lower ecosystem respiration (Reco) during the first year. The combined suppression of GPP and Reco in the first year of Autochamber measurements could be the result of the experimental setup. Root damage associated with Autochamber soil collar installation may have lowered the plant community's capacity to fix C, but recovered within 3 years. And while this ecosystem was a consistent CO 2 sink during the summer, CO 2 emissions during the nonsummer months offset summer CO 2 uptake each year.« less
2008-11-03
CAPE CANAVERAL, Fla. – On Launch Pad 17-B at Cape Canaveral Air Force Station in Florida, the final solid rocket booster is ready to be lifted into the mobile service tower, joining two others that will be mated to the first stage of the Kepler's Delta 2 launch vehicle. The Kepler mission is specifically designed to survey our region of the Milky Way galaxy to discover hundreds of Earth-size and smaller planets in or near the habitable zone and determine how many of the billions of stars in our galaxy have such planets. Results from this mission will allow us to place our solar system within the continuum of planetary systems in the Galaxy. NASA's planet-hunting Kepler mission is scheduled to launch no earlier than March 5, 2009. Photo credit: NASA/Jim Grossmann
Plan Representations for Distributed Planning and Execution
2011-08-01
Edinburgh AIAI, School of Informatics Appleton Tower, Crichton Street Edinburgh, Scotland, United Kingdom EH8 9LE EOARD GRANT 09-3090...Edinburgh Appleton Tower, Crichton Street Edinburgh, Scotland , United Kingdom EH8 9LE 8. PERFORMING ORGANIZATION REPORT NUMBER N/A...α → abandon α 5 4 pe rf or m in g 8 7 pe rf or m in g → abandon α 6 Figure 14: Abandoning Execution pecially negative effects, e.g. when a robot
Solar tower enhanced natural draft dry cooling tower
NASA Astrophysics Data System (ADS)
Yang, Huiqiang; Xu, Yan; Acosta-Iborra, Alberto; Santana, Domingo
2017-06-01
Concentrating Solar Power (CSP) plants are located in desert areas where the Direct Normal Irradiance (DNI) value is very high. Since water resource is scarcely available, mechanical draft cooing technology is commonly used, with power consumption of mechanical fans being approximately 2% of the total power generated. Today, there is only one solar power plant (Khi Solar One in South Africa) uses a condenser installed in a Natural Draft Cooling (NDC) tower that avoids the windage loss of water occurring in wet cooling towers. Although, Khi Solar One is a cavity receiver power tower, the receivers can be hung onto the NDC tower. This paper looks at a novel integration of a NDC tower into an external molten salt receiver of a solar power plant, which is one of a largest commercial molten salt tower in China, with 100MWe power capacity. In this configuration study, the NDC tower surrounds the concrete tower of the receiver concentrically. In this way, the receiver concrete tower is the central support of the NDC tower, which consists of cable networks that are fixed to the concrete tower and suspended at a certain height over the floor. The cable networks support the shell of the NDC tower. To perform a preliminary analysis of the behavior of this novel configuration, two cases of numerical simulation in three dimensional (3D) models have been solved using the commercial Computational Fluid Dynamics (CFD) code, ANSYS Fluent 6.3. The results show that the integration of the NDC tower into an external central receiver tower is feasible. Additionally, the total heat transfer rate is not reduced but slightly increases when the molten salt receiver is in operation because of the additional natural draft induced by the high temperature of the receiver.
Yamaguchi, Nobuyasu; Tokunaga, Yusuke; Goto, Satoko; Fujii, Yudai; Banno, Fumiya; Edagawa, Akiko
2017-06-08
Legionnaires' disease, predominantly caused by the bacterium Legionella pneumophila, has increased in prevalence worldwide. The most common mode of transmission of Legionella is inhalation of contaminated aerosols, such as those generated by cooling towers. Simple, rapid and accurate methods to enumerate L. pneumophila are required to prevent the spread of this organism. Here, we applied a microfluidic device for on-chip fluorescent staining and semi-automated counting of L. pneumophila in cooling tower water. We also constructed a portable system for rapid on-site monitoring and used it to enumerate target bacterial cells rapidly flowing in the microchannel. A fluorescently-labelled polyclonal antibody was used for the selective detection of L. pneumophila serogroup 1 in the samples. The counts of L. pneumophila in cooling tower water obtained using the system and fluorescence microscopy were similar. The detection limit of the system was 10 4 cells/ml, but lower numbers of L. pneumophila cells (10 1 to 10 3 cells/ml) could be detected following concentration of 0.5-3 L of the water sample by filtration. Our technique is rapid to perform (1.5 h), semi-automated (on-chip staining and counting), and portable for on-site measurement, and it may therefore be effective in the initial screening of Legionella contamination in freshwater.
Scalar versus fermionic top partner interpretations of toverline{t}+{E}_T^{miss} searches at the LHC
NASA Astrophysics Data System (ADS)
Kraml, Sabine; Laa, Ursula; Panizzi, Luca; Prager, Hugo
2016-11-01
We assess how different ATLAS and CMS searches for supersymmetry in the toverline{t}+{E}_T^{miss} final state at Run 1 of the LHC constrain scenarios with a fermionic top partner and a dark matter candidate. We find that the efficiencies of these searches in all-hadronic, 1-lepton and 2-lepton channels are quite similar for scalar and fermionic top partners. Therefore, in general, efficiency maps for stop-neutralino simplified models can also be applied to fermionic top-partner models, provided the narrow width approximation holds in the latter. Owing to the much higher production cross-sections of heavy top quarks as compared to stops, masses up to m T ≈ 850 GeV can be excluded from the Run 1 stop searches. Since the simplified-model results published by ATLAS and CMS do not extend to such high masses, we provide our own efficiency maps obtained with C heckMATE and M adA nalysis 5 for these searches. Finally, we also discuss how generic gluino/squark searches in multi-jet final states constrain heavy top partner production.
Tower wake/blade interaction noise of a wind turbine
NASA Astrophysics Data System (ADS)
Nishiwaki, Hideo; Takeda, Katsumi
1987-10-01
A scale model of a 1.5m dia. two-bladed windturbine was used in an anechoic chamber that provided a free-stream velocity of 8m/s. The blades used were a 1.5/8 scale model of a test machine for a local energy utilization project promoted by the Science and Technology Agency. The height of the tower from the ground level was 1.8m. The acoustic measurements were made in a circle of 1.6m downstream from the machine at the height of the windmill centerline. The noise level of the on-axis spectra was about 15dB larger than that of the off-axis. This is a result of the dipole nature of the acoustic impulse. The Wortmann airfoil (FX 77-W series) was employed for the blade profiles and the Reynolds number was 10(5), based on the tip chord length. The experiment revealed that the sound intensity at each harmonic was not proportional to the axial and radial extents of the wake. The elliptic slender configuration was the quietest, while the square configuration was the loudest. From a practical point of view, it is suggested that the circular section is most suitable for the tower leg.
13. INTERIOR VIEW OF TOWER OFFICE SHOWING CONTROL TOWER DESK, ...
13. INTERIOR VIEW OF TOWER OFFICE SHOWING CONTROL TOWER DESK, FACING NORTHWEST. - U.S. Naval Base, Pearl Harbor, Signal Tower, Corner of Seventh Street & Avenue D east of Drydock No. 1, Pearl City, Honolulu County, HI
Evaluation of dynamic response for monopole and hybrid wind mill tower
NASA Astrophysics Data System (ADS)
Shah, Hemal J.; Desai, Atul K.
2017-07-01
The wind mill towers are constructed using monopoles or lattice type tower. As the height of tower increases it gives more power but it becomes uneconomical, so in the present research work innovative wind mill tower such as combination of monopole and lattice tower is analyzed using FEM software. When the tall structures are constructed on soft soil it becomes dynamically sensitive so 3 types of soil such as hard, medium and soft soil is also modeled and the innovative tower is studied for different operating frequencies of wind turbine. From study it is concluded that the innovative tower will reduce resonance condition considering soil structure interaction.
Towers for Offshore Wind Turbines
NASA Astrophysics Data System (ADS)
Kurian, V. J.; Narayanan, S. P.; Ganapathy, C.
2010-06-01
Increasing energy demand coupled with pollution free production of energy has found a viable solution in wind energy. Land based windmills have been utilized for power generation for more than two thousand years. In modern times wind generated power has become popular in many countries. Offshore wind turbines are being used in a number of countries to tap the energy from wind over the oceans and convert to electric energy. The advantages of offshore wind turbines as compared to land are that offshore winds flow at higher speed than onshore winds and the more available space. In some land based settings, for better efficiency, turbines are separated as much as 10 rotor diameters from each other. In offshore applications where only two wind directions are likely to predominate, the distances between the turbines arranged in a line can be shortened to as little as two or four rotor diameters. Today, more than a dozen offshore European wind facilities with turbine ratings of 450 kw to 3.6 MW exist offshore in very shallow waters of 5 to 12 m. Compared to onshore wind turbines, offshore wind turbines are bigger and the tower height in offshore are in the range of 60 to 80 m. The water depths in oceans where offshore turbines can be located are within 30 m. However as the distance from land increases, the costs of building and maintaining the turbines and transmitting the power back to shore also increase sharply. The objective of this paper is to review the parameters of design for the maximum efficiency of offshore wind turbines and to develop types offshore towers to support the wind turbines. The methodology of design of offshore towers to support the wind turbine would be given and the environmental loads for the design of the towers would be calculated for specific cases. The marine corrosion on the towers and the methods to control the corrosion also would be briefly presented. As the wind speeds tend to increase with distance from the shore, turbines build father offshore will be able to capture more wind energy. Currently two types of towers are considered. Cylindrical tubular structures and truss type structures. But truss type structures have less weight and flexibility in design. The construction of the offshore towers to harness the wind energy is also presented. The results will include the calculation of wind and wave forces on the tower and the design details for the tower.
78 FR 14697 - Final Flood Elevation Determinations
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-07
... Communities affected elevation above ground [caret] Elevation in meters (MSL) Modified Cecil County, Maryland... 1 to Stone Run At the Stone Run +271 Town of Rising Sun, confluence. Unincorporated Areas of Cecil County. Approximately 460 feet +359 downstream of Pierce Road. Tributary 2 to Stone Run At the Stone Run...
Legionella spp. in Puerto Rico cooling towers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Negron-Alvira, A.; Perez-Suarez, I.; Hazen, T.C.
1988-10-01
Water samples from air conditioning cooling towers receiving different treatment protocols on five large municipal buildings in San Juan, P.R., were assayed for various Legionella spp. and serogroups by using direct immunofluorescence. Several water quality parameters were also measured for each sample. Guinea pigs were inoculated with water samples to confirm pathogenicity and recover viable organisms. Legionella pneumophila serogroups 1 to 6, L. bozemanii, L. micdadei, L. dumoffii, and L. gormanii were observed in at least one of the cooling towers. L. pneumophila was the most abundant species; its density reached 10{sup 5} cells per ml, which is within themore » range that is considered potentially pathogenic to humans. A significantly higher density of L. pneumophila was observed in the cooling tower water that was not being treated with biocides. Percent respiration (INT) and total cell activity (acridine orange direct count) were inversely correlated with bacterial density. This study demonstrates that Legionella spp. are present in tropical air-conditioning cooling systems and that, without continuous biocide treatment, they may reach densities that present a health risk.« less
CASTILLA, J.; BARRICARTE, A.; ALDAZ, J.; GARCÍA CENOZ, M.; FERRER, T.; PELAZ, C.; PINEDA, S.; BALADRÓN, B.; MARTÍN, I.; GOÑI, B.; ARATAJO, P.; CHAMORRO, J.; LAMEIRO, F.; TORROBA, L.; DORRONSORO, I.; MARTÍNEZ-ARTOLA, V.; ESPARZA, M. J.; GASTAMINZA, M. A.; FRAILE, P.; ALDAZ, P.
2008-01-01
SUMMARY An outbreak of Legionnaire's disease was detected in Pamplona, Spain, on 1 June 2006. Patients with pneumonia were tested to detect Legionella pneumophila antigen in urine (Binax Now; Binax Inc., Scarborough, ME, USA), and all 146 confirmed cases were interviewed. The outbreak was related to district 2 (22 012 inhabitants), where 45% of the cases lived and 50% had visited; 5% lived in neighbouring districts. The highest incidence was found in the resident population of district 2 (3/1000 inhabitants), section 2 (14/1000). All 31 cooling towers of district 2 were analysed. L. pneumophila antigen (Binax Now) was detected in four towers, which were closed on 2 June. Only the strain isolated in a tower situated in section 2 of district 2 matched all five clinical isolates, as assessed by mAb and two genotyping methods, AFLP and PFGE. Eight days after closing the towers, new cases ceased appearing. Early detection and rapid coordinated medical and environmental actions permitted immediate control of the outbreak and probably contributed to the null case fatality. PMID:17662166
NREL National Wind Technology Center (NWTC): M2 Tower; Boulder, Colorado (Data)
Jager, D.; Andreas, A.
1996-09-24
The National Wind Technology Center (NWTC), located at the foot of the Rocky Mountains near Boulder, Colorado, is a world-class research facility managed by NREL for the U.S. Department of Energy. NWTC researchers work with members of the wind energy industry to advance wind power technologies that lower the cost of wind energy through research and development of state-of-the-art wind turbine designs. NREL's Measurement and Instrument Data Center provides data from NWTC's M2 tower which are derived from instruments mounted on or near an 82 meter (270 foot) meteorological tower located at the western edge of the NWTC site and about 11 km (7 miles) west of Broomfield, and approximately 8 km (5 miles) south of Boulder, Colorado. The data represent the mean value of readings taken every two seconds and averaged over one minute. The wind speed and direction are measured at six heights on the tower and air temperature is measured at three heights. The dew point temperature, relative humidity, barometric pressure, totalized liquid precipitation, and global solar radiation are also available.
Castilla, J; Barricarte, A; Aldaz, J; García Cenoz, M; Ferrer, T; Pelaz, C; Pineda, S; Baladrón, B; Martín, I; Goñi, B; Aratajo, P; Chamorro, J; Lameiro, F; Torroba, L; Dorronsoro, I; Martínez-Artola, V; Esparza, M J; Gastaminza, M A; Fraile, P; Aldaz, P
2008-06-01
An outbreak of Legionnaire's disease was detected in Pamplona, Spain, on 1 June 2006. Patients with pneumonia were tested to detect Legionella pneumophila antigen in urine (Binax Now; Binax Inc., Scarborough, ME, USA), and all 146 confirmed cases were interviewed. The outbreak was related to district 2 (22 012 inhabitants), where 45% of the cases lived and 50% had visited; 5% lived in neighbouring districts. The highest incidence was found in the resident population of district 2 (3/1000 inhabitants), section 2 (14/1000). All 31 cooling towers of district 2 were analysed. L. pneumophila antigen (Binax Now) was detected in four towers, which were closed on 2 June. Only the strain isolated in a tower situated in section 2 of district 2 matched all five clinical isolates, as assessed by mAb and two genotyping methods, AFLP and PFGE. Eight days after closing the towers, new cases ceased appearing. Early detection and rapid coordinated medical and environmental actions permitted immediate control of the outbreak and probably contributed to the null case fatality.
Wheel-running reinforcement in free-feeding and food-deprived rats.
Belke, Terry W; Pierce, W David
2016-03-01
Rats experiencing sessions of 30min free access to wheel running were assigned to ad-lib and food-deprived groups, and given additional sessions of free wheel activity. Subsequently, both ad-lib and deprived rats lever pressed for 60s of wheel running on fixed ratio (FR) 1, variable ratio (VR) 3, VR 5, and VR 10 schedules, and on a response-initiated variable interval (VI) 30s schedule. Finally, the ad-lib rats were switched to food deprivation and the food-deprived rats were switched to free food, as rats continued responding on the response-initiated VI 30-s schedule. Wheel running functioned as reinforcement for both ad-lib and food-deprived rats. Food-deprived rats, however, ran faster and had higher overall lever-pressing rates than free-feeding rats. On the VR schedules, wheel-running rates positively correlated with local and overall lever pressing rates for deprived, but not ad-lib rats. On the response-initiated VI 30s schedule, wheel-running rates and lever-pressing rates changed for ad-lib rats switched to food deprivation, but not for food-deprived rats switched to free-feeding. The overall pattern of results suggested different sources of control for wheel running: intrinsic motivation, contingencies of automatic reinforcement, and food-restricted wheel running. An implication is that generalizations about operant responding for wheel running in food-deprived rats may not extend to wheel running and operant responding of free-feeding animals. Copyright © 2015 Elsevier B.V. All rights reserved.
Tower Temperature and Humidity Sensors (TWR) Handbook
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cook, DR
2010-02-01
Three tall towers are installed at the Atmospheric Radiation Measurement (ARM) Climate Research Facility: a 60-meter triangular tower at the Southern Great Plains (SGP) Central Facility (CF), a 21-meter walkup scaffolding tower at the SGP Okmulgee forest site (E21), and a 40-meter triangular tower at the North Slope of Alaska (NSA) Barrow site. The towers are used for meteorological, radiological, and other measurements.
SWECS tower dynamics analysis methods and results
NASA Technical Reports Server (NTRS)
Wright, A. D.; Sexton, J. H.; Butterfield, C. P.; Thresher, R. M.
1981-01-01
Several different tower dynamics analysis methods and computer codes were used to determine the natural frequencies and mode shapes of both guyed and freestanding wind turbine towers. These analysis methods are described and the results for two types of towers, a guyed tower and a freestanding tower, are shown. The advantages and disadvantages in the use of and the accuracy of each method are also described.
Winnebago Resource Study. Cooperative Research and Development Final Report, CRADA Number CRD-09-329
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jimenez, A.; Robichaud, R.
2015-03-01
Since 2005 the NREL Native American Tall Tower Loan program has assisted Native American tribes to assess their wind resource by lending tall (30m - 50m) anemometer. This program has allowed tribes a lower risk way to gather financeable wind data for potential utility scale wind energy projects. These projects offer Tribes a significant economic development opportunity.
SMART Rotor Development and Wind Tunnel Test
2009-09-01
amplifier and control system , and data acquisition, processing, and display systems . Boeing�s LRTS (Fig. 2), consists of a sled structure that...Support Test Stand Sled Tail Sting Outrigger Arm Figure 2: System integration test at whirl tower Port Rotor Balance Main Strut Flap Tail...demonstrated. Finally, the reliability of the flap actuation system was successfully proven in more than 60 hours of wind tunnel testing
Second stage of Saturn V being assembled with the first stage.
NASA Technical Reports Server (NTRS)
1965-01-01
The hydrogen-powered second stage is being lowered into place during the final phase of fabrication of the Saturn V moon rocket at North American's Seal Beach, California facility. The towering 363-foot Saturn V was a multi-stage, multi-engine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.
Physiological correlates of 2-mile run performance as determined using a novel on-demand treadmill.
Tolfrey, Keith; Hansen, Simon A; Dutton, Katie; McKee, Tom; Jones, Andrew M
2009-08-01
The purpose of this study was to assess the reproducibility of an on-demand motorised treadmill to measure 2-mile (3.2 km) race performance and to examine the physiological variables that best predict this free-running performance in active men. Twelve men (mean (SD): age, 28 (9) years; stature, 1.79 (0.05) m; body mass, 72 (9) kg) completed the study in which maximum oxygen uptake (VO2 max), running economy, and running speedin the abstract section. They appear in the rest of the paper.), running economy, and running speed at VO2 max (vVO2 max), lactate threshold (vLT), and 4 mmol.L-1 fixed blood lactate concentration (v4) were measured. Subsequently, the maximal lactate steady state (MLSS) was identified using a series of 30-min treadmill runs. Finally, each participant completed a 2-mile running performance trial on 2 separate occasions, using an on-demand treadmill that adjusts belt speed according to the participant's position on the moving belt. The average 2-mile run speed was 15.7 (SD, 1.9) km.h-1, with small individual differences between repeat-performance trials (intraclass correlation coefficient = 0.99, 95% CI 0.953 to 0.996; standard error of measurement as coefficient of variation = 1.5%, 95% CI 1.0% to 2.5%). Bivariate regression analyses identified VO2 max, vVO2 max, VO2 (mL.kg-1.min-1) at MLSS, vLT, v4, and velocity at MLSS (vMLSS) as the strongest individual predictor variables (r2 = 0.69 to 0.87; standard error of the estimate = 1.08 to 0.72 km.h-1) for 2-mile running performance. The vLT and vMLSS explained 85% and 87% of the variance in running performance, respectively, suggesting that there is considerable shared variance between these parameters. In conclusion, the on-demand treadmill system provided a reliable measure of distance running performance. Both vLT and vMLSS were strong predictors of 2-mile running performance, with vMLSS explaining marginally more of the variance.
NASA Astrophysics Data System (ADS)
Mohammadi, Ebrahim; Fadaeinedjad, Roohollah; Moschopoulos, Gerry
2018-05-01
Vibration control and fatigue loads reduction are important issues in large-scale wind turbines. Identifying the vibration frequencies and tuning dampers and controllers at these frequencies are major concerns in many control methods. In this paper, an internal model control (IMC) method with an adaptive algorithm is implemented to first identify the vibration frequency of the wind turbine tower and then to cancel the vibration signal. Standard individual pitch control (IPC) is also implemented to compare the performance of the controllers in term of fatigue loads reduction. Finally, the performance of the system when both controllers are implemented together is evaluated. Simulation results demonstrate that using only IMC or IPC alone has advantages and can reduce fatigue loads on specific components. IMC can identify and suppress tower vibrations in both fore-aft and side-to-side directions, whereas, IPC can reduce fatigue loads on blades, shaft and yaw bearings. When both IMC and IPC are implemented together, the advantages of both controllers can be used. The aforementioned analysis and comparisons were not studied in literature and this study fills this gap. FAST, AreoDyn and Simulink are used to simulate the mechanical, aerodynamic and electrical aspects of wind turbine.
2004-08-05
KENNEDY SPACE CENTER, FLA. - After the ribbon cutting for the Enhanced Firing Range on Schwartz Rd. at Kennedy Space Center, guests get a close look at the new “rifle-grade” shoot house. NASA’s Federal Law Enforcement Training Academy’s firing range upgrades also include a portable, tactical “shoot-back” trailer for cover and concealment drills, automated running targets and a new classroom. They are added to the existing three firearms ranges, “pistol-grade” shoot house, obstacle course and rappel tower. NASA’s Security Management and Safeguards Office funded the enhancements in order to improve ability to train the KSC security force and to support local, state and federal law enforcement agencies in Homeland Security.
2004-08-05
KENNEDY SPACE CENTER, FLA. - At the ribbon cutting for the Enhanced Firing Range on Schwartz Rd. at Kennedy Space Center, a SWAT team demonstrates use of the facility. NASA’s Federal Law Enforcement Training Academy’s firing range has been upgraded to include a “rifle-grade” shoot house, a portable, tactical “shoot-back” trailer for cover and concealment drills, automated running targets and a new classroom. They are added to the existing three firearms ranges, “pistol-grade” shoot house, obstacle course and rappel tower. NASA’s Security Management and Safeguards Office funded the enhancements in order to improve ability to train the KSC security force and to support local, state and federal law enforcement agencies in Homeland Security.
2004-08-05
KENNEDY SPACE CENTER, FLA. - Center Director Jim Kennedy addresses guests at the ribbon cutting for the Enhanced Firing Range on Schwartz Rd. at Kennedy Space Center. NASA’s Federal Law Enforcement Training Academy’s firing range has been upgraded to include a “rifle-grade” shoot house, a portable, tactical “shoot-back” trailer for cover and concealment drills, automated running targets and a new classroom facility. They are added to the existing three firearms ranges, “pistol-grade” shoot house, obstacle course and rappel tower. NASA’s Security Management and Safeguards Office funded the enhancements in order to improve ability to train the KSC security force and to support local, state and federal law enforcement agencies in Homeland Security.
Wind tunnel tests of a free yawing downwind wind turbine
NASA Astrophysics Data System (ADS)
Verelst, D. R. S.; Larsen, T. J.; van Wingerden, J. W.
2014-12-01
This research paper presents preliminary results on a behavioural study of a free yawing downwind wind turbine. A series of wind tunnel tests was performed at the TU Delft Open Jet Facility with a three bladed downwind wind turbine and a rotor radius of 0.8 meters. The setup includes an off the shelf three bladed hub, nacelle and generator on which relatively flexible blades are mounted. The tower support structure has free yawing capabilities provided at the base. A short overview on the technical details of the experiment is given as well as a brief summary of the design process. The discussed test cases show that the turbine is stable while operating in free yawing conditions. Further, the effect of the tower shadow passage on the blade flapwise strain measurement is evaluated. Finally, data from the experiment is compared with preliminary simulations using DTU Wind Energy's aeroelastic simulation program HAWC2.
Titan 4B/Centaur/Cassini Service Tower Rollaway
NASA Technical Reports Server (NTRS)
1997-01-01
KENNEDY SPACE CENTER, FLA. -- At Launch Complex 40 on Cape Canaveral Air Station, the Mobile Service Tower is rolled away from the Titan IVB/Centaur carrying the Cassini spacecraft, marking a major milestone in the launch countdown sequence. Retraction of the structure began about an hour later than scheduled due to minor problems with ground support equipment. The countdown clock for the Cassini mission began ticking earlier today at the T-26-hour mark. Other upcoming prelaunch milestones include activation of the final launch sequence for the Cassini spacecraft at the T-180-minute mark in the countdown, to be followed about an hour later by initiation of loading of the Titan IVB's Centaur stage with its complement of liquid hydrogen and liquid oxygen. Liftoff of Cassini on the journey to Saturn and its moon Titan is slated to occur during a window opening at 4:55 a.m. EDT, Oct. 13, and extending through 7:15 a.m.
Wet cooling towers: rule-of-thumb design and simulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leeper, Stephen A.
1981-07-01
A survey of wet cooling tower literature was performed to develop a simplified method of cooling tower design and simulation for use in power plant cycle optimization. The theory of heat exchange in wet cooling towers is briefly summarized. The Merkel equation (the fundamental equation of heat transfer in wet cooling towers) is presented and discussed. The cooling tower fill constant (Ka) is defined and values derived. A rule-of-thumb method for the optimized design of cooling towers is presented. The rule-of-thumb design method provides information useful in power plant cycle optimization, including tower dimensions, water consumption rate, exit air temperature,more » power requirements and construction cost. In addition, a method for simulation of cooling tower performance at various operating conditions is presented. This information is also useful in power plant cycle evaluation. Using the information presented, it will be possible to incorporate wet cooling tower design and simulation into a procedure to evaluate and optimize power plant cycles.« less
7. VIEW NORTHWEST OF 'ISLAND' (TOWER OR SUPERSTRUCTURE) ON THE ...
7. VIEW NORTHWEST OF 'ISLAND' (TOWER OR SUPERSTRUCTURE) ON THE DECK OF THE AIRCRAFT CARRIER JOHN F. KENNEDY. WHEN THE PHOTOGRAPH WAS TAKEN IN SEPTEMBER 1994, THE KENNEDY WAS IN DRY-DOCK FOR REFURBISHMENT UNDER THE 'SERVICE LIFE EXTENSION PROGRAM (SLEP). THE 'ISLAND' HOUSES THE SHIP'S BRIDGE AND A CONTROL CENTER FOR AIRCRAFT OPERATIONS. EXTENSIVE SCAFFOLDING WAS REQUIRED TO ALLOW FULL ACCESS TO THE PAINTERS AND TECHNICIANS WORKING HERE. - Naval Base Philadelphia-Philadelphia Naval Shipyard, Dry Dock No. 5, League Island, Philadelphia, Philadelphia County, PA
LOOKING WEST FROM THE TOP OF THE WATER TOWER AT ...
LOOKING WEST FROM THE TOP OF THE WATER TOWER AT ROOFTOPS OF INDUSTRIAL SHEDS. BUILDINGS IN THE FOREGROUND INCLUDE THE SHIPPING BAYS OF THE STRUCTURAL MILL AND MAIN ROLL SHOP. BUILDINGS IN THE MIDDLE GROUND INCLUDE PRESS SHOP NO. 2, CHIPPING YARD, BLACKSMITH SHOP, AND MACHINE SHOP NO. 1. THE TALLEST STRUCTURE IS THE VERTICAL FURNACE BUILDING, AND OPEN HEARTH NO. 5 IS IN THE EXTREME BACKGROUND. - U.S. Steel Homestead Works, Structural Mill, Along Monongahela River, Homestead, Allegheny County, PA
2015-08-01
for the collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data ...sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden...UNCLASSIFIED UNCLASSIFIED • Baseline drop tower data collected from Anthropomorphic Test Devices (ATDs) seated in 12 models of Commercial Off-The-Shelf
Improved performance of the LHCb Outer Tracker in LHC Run 2
NASA Astrophysics Data System (ADS)
d'Argent, P.; Dufour, L.; Grillo, L.; de Vries, J. A.; Ukleja, A.; Aaij, R.; Archilli, F.; Bachmann, S.; Berninghoff, D.; Birnkraut, A.; Blouw, J.; De Cian, M.; Ciezarek, G.; Färber, C.; Demmer, M.; Dettori, F.; Gersabeck, E.; Grabowski, J.; Hulsbergen, W. D.; Khanji, B.; Kolpin, M.; Kucharczyk, M.; Malecki, B. P.; Merk, M.; Mulder, M.; Müller, J.; Mueller, V.; Pellegrino, A.; Pikies, M.; Rachwal, B.; Schmelzer, T.; Spaan, B.; Szczekowski, M.; van Tilburg, J.; Tolk, S.; Tuning, N.; Uwer, U.; Wishahi, J.; Witek, M.
2017-11-01
The LHCb Outer Tracker is a gaseous detector covering an area of 5 × 6 m2 with 12 double layers of straw tubes. The performance of the detector is presented based on data of the LHC Run 2 running period from 2015 and 2016. Occupancies and operational experience for data collected in pp, pPb and PbPb collisions are described. An updated study of the ageing effects is presented showing no signs of gain deterioration or other radiation damage effects. In addition several improvements with respect to LHC Run 1 data taking are introduced. A novel real-time calibration of the time-alignment of the detector and the alignment of the single monolayers composing detector modules are presented, improving the drift-time and position resolution of the detector by 20%. Finally, a potential use of the improved resolution for the timing of charged tracks is described, showing the possibility to identify low-momentum hadrons with their time-of-flight.
Observed drag coefficients in high winds in the near offshore of the South China Sea
Bi, Xueyan; Liu, Yangan; Gao, Zhiqiu; ...
2015-07-14
This paper investigates the relationships between friction velocity, 10 m drag coefficient, and 10 m wind speed using data collected at two offshore observation towers (one over the sea and the other on an island) from seven typhoon episodes in the South China Sea from 2008 to 2014. The two towers were placed in areas with different water depths along a shore-normal line. The depth of water at the tower over the sea averages about 15 m, and the depth of water near the island is about 10 m. The observed maximum 10 min average wind speed at a heightmore » of 10 m is about 32 m s⁻¹. Momentum fluxes derived from three methods (eddy covariance, inertial dissipation, and flux profile) are compared. The momentum fluxes derived from the flux profile method are larger (smaller) over the sea (on the island) than those from the other two methods. The relationship between the 10 m drag coefficient and the 10 m wind speed is examined by use of the data obtained by the eddy covariance method. The drag coefficient first decreases with increasing 10 m wind speed when the wind speeds are 5–10 m s⁻¹, then increases and reaches a peak value of 0.002 around a wind speed of 18 m s⁻¹. The drag coefficient decreases with increasing 10 m wind speed when 10 m wind speeds are 18–27 m s⁻¹. A comparison of the measurements from the two towers shows that the 10 m drag coefficient from the tower in 10 m water depth is about 40% larger than that from the tower in 15 m water depth when the 10 m wind speed is less than 10 m s⁻¹. Above this, the difference in the 10 m drag coefficients of the two towers disappears.« less
Observed drag coefficients in high winds in the near offshore of the South China Sea
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bi, Xueyan; Liu, Yangan; Gao, Zhiqiu
This paper investigates the relationships between friction velocity, 10 m drag coefficient, and 10 m wind speed using data collected at two offshore observation towers (one over the sea and the other on an island) from seven typhoon episodes in the South China Sea from 2008 to 2014. The two towers were placed in areas with different water depths along a shore-normal line. The depth of water at the tower over the sea averages about 15 m, and the depth of water near the island is about 10 m. The observed maximum 10 min average wind speed at a heightmore » of 10 m is about 32 m s⁻¹. Momentum fluxes derived from three methods (eddy covariance, inertial dissipation, and flux profile) are compared. The momentum fluxes derived from the flux profile method are larger (smaller) over the sea (on the island) than those from the other two methods. The relationship between the 10 m drag coefficient and the 10 m wind speed is examined by use of the data obtained by the eddy covariance method. The drag coefficient first decreases with increasing 10 m wind speed when the wind speeds are 5–10 m s⁻¹, then increases and reaches a peak value of 0.002 around a wind speed of 18 m s⁻¹. The drag coefficient decreases with increasing 10 m wind speed when 10 m wind speeds are 18–27 m s⁻¹. A comparison of the measurements from the two towers shows that the 10 m drag coefficient from the tower in 10 m water depth is about 40% larger than that from the tower in 15 m water depth when the 10 m wind speed is less than 10 m s⁻¹. Above this, the difference in the 10 m drag coefficients of the two towers disappears.« less
17. VIEW OF THE TOP OF THE TOWER SHOWING BASE ...
17. VIEW OF THE TOP OF THE TOWER SHOWING BASE OF TOWER MAST AND WOOD DECKING ON SIGNAL TOWER ROOF. - U.S. Naval Base, Pearl Harbor, Signal Tower, Corner of Seventh Street & Avenue D east of Drydock No. 1, Pearl City, Honolulu County, HI
Measurement of fluid dynamic loading on staphylococci bacteria bio-film structures using μPIV
NASA Astrophysics Data System (ADS)
Sherman, Erica; Moormeier, Derek; Bayles, Kenneth; Davidson, John; Ryu, Sangjin; Wei, Timothy
2013-11-01
Staphylococci bacteria are recognized as the most frequent cause of biofilm-associated infections. Although humans are regularly exposed to these bacteria without consequence, a localized infection can enter the bloodstream and lead to serious infections such as endocarditis, pneumonia, or toxic shock syndrome. The mechanics of staphylococci biofilm formation and dispersion through the bloodstream are not well known. It has recently been observed that under certain flow conditions, bacteria organize in tower-like structures which break and are transported downstream by the flow. The fundamental questions of interest are i) whether or not fluid mechanics plays a role in differentiating between film or tower formation and ii) whether or not the faulty towers are a bio-film propagation mechanism. This talk focuses on the application of μPIV to study this problem. Staphylococcus aureus bacteria were cultured in the Bioflux Fluxion square microchannel of a 65 by 65 um cross section, and subjected to a steady shear rate of 0.5 dynes. μPIV measurements were made to map the flow over and around a biofilm tower structure which occluded approximately 66% of the channel width. Data were recorded around the structure at a series of two dimensional planes, which when stacked vertically show a two dimensional flow field as a function of tower height. Measurements and control volume analysis will be presented quantifying forces acting on these structures.
NASA Astrophysics Data System (ADS)
Newman, Seth Aaron
Peccei and Quinn proposed an elegant solution for restoring CP symmetry to the QCD Lagrangian [37]. This method includes an additional global U(1) symmetry included in the QCD Lagrangian which is spontaneously broken at a high energy scale, fa. Breaking the symmetry generates a Nambu-Goldstone boson called the axion. Although there are various detection mechanisms that search for the axion, this thesis focuses on the the axio-electric effect. The axio-electric is similar to the photo-electric effect in that an axion is absorbed by an atom which subsequently emits an electron. The electron's energy is equivalent to the incoming axion energy minus the binding energy. The higher shell electrons immediately replenish the missing binding energy yielding a single energy peak at the incoming axion's energy. The 14.4 keV M1 transition of 57Fe is one possible axion source. The development of an optimum trigger algorithm has lowered the threshold for analysis in TeO2 bolometers to a few keV making an axion signature accessible to CUORE related R&D experiments such as the Chinese Crystal Validation Runs (CCVR) and Three Towers Test (TTT). These TeO2 crystal detectors have masses 750 and 790 grams, respectively. Each crystal has a stabilization heater and a germanium thermometer attached to its surface by an epoxy glue. The two previous experiments are R&D tests for the upcoming larger experiment, CUORE. CUORE will be made of 988 TeO2 crystals arranged in 19 towers with 13 floors each, each floor with 4 detectors. This thesis examined 87.01 kg·days of Three Towers data for an axion signal. A peak is observed in the region of interest with a statistical significance less than 1sigma over the expected background fluctuations, yielding a total background rate of 0.185 +/- 0.001 (Stat.) +/- 0.006 (Syst.) Counts/kg/day at 95% C.L. This places an experimental limit on the coupling constant fa of f a (S = 0.50) ≥ 1.16 x 106 GeV at 95% C.L. Projecting the TTT result to the CUORE mass and a five year run time we can expect a limit of fa(S = 0.50) ≥ 2.21 x 106 GeV at 95% C.L. Improvements in granularity can strengthen the bound on fa by 8% and 25% for background reductions by a factor of 2 and 10, respectively.
You're a What?: Tower Technician
ERIC Educational Resources Information Center
Vilorio, Dennis
2012-01-01
In this article, the author talks about the role and functions of a tower technician. A tower technician climbs up the face of telecommunications towers to remove, install, test, maintain, and repair a variety of equipment--from antennas to light bulbs. Tower technicians also build shelters and radiofrequency shields for electronic equipment, lay…
Vibration analysis of three guyed tower designs for intermediate size wind turbines
NASA Technical Reports Server (NTRS)
Christie, R. J.
1982-01-01
Three guyed tower designs were analyzed for intermediate size wind turbines. The four lowest natural frequencies of vibration of the three towers concepts were estimated. A parametric study was performed on each tower to determine the effect of varying such tower properties as the inertia and stiffness of the tower and guys, the inertia values of the nacelle and rotor, and the rotational speed of the rotor. Only the two lowest frequencies were in a range where they could be excited by the rotor blade passing frequencies. There two frequencies could be tuned by varying the guy stiffness, the guy attachment point on the tower, the tower and mass stiffness, and the nacelle/rotor/power train masses.
Lifting system and apparatus for constructing wind turbine towers
Livingston, Tracy; Schrader, Terry; Goldhardt, James; Lott, James
2011-02-01
The disclosed invention is utilized for mounting a wind turbine and blade assembly on the upper end of a wind turbine tower. The invention generally includes a frame or truss that is pivotally secured to the top bay assembly of the tower. A transverse beam is connected to the frame or truss and extends fore of the tower when the frame or truss is in a first position and generally above the tower when in a second position. When in the first position, a wind turbine or blade assembly can be hoisted to the top of the tower. The wind turbine or blade assembly is then moved into position for mounting to the tower as the frame or truss is pivoted to a second position. When the turbine and blade assembly are secured to the tower, the frame or truss is disconnected from the tower and lowered to the ground.
2004 Savannah River Cooling Tower Collection (U)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garrett, Alfred; Parker, Matthew J.; Villa-Aleman, E.
2005-05-01
The Savannah River National Laboratory (SRNL) collected ground truth in and around the Savannah River Site (SRS) F-Area cooling tower during the spring and summer of 2004. The ground truth data consisted of air temperatures and humidity inside and around the cooling tower, wind speed and direction, cooling water temperatures entering; inside adn leaving the cooling tower, cooling tower fan exhaust velocities and thermal images taken from helicopters. The F-Area cooling tower had six cells, some of which were operated with fans off during long periods of the collection. The operating status (fan on or off) for each of themore » six cells was derived from operations logbooks and added to the collection database. SRNL collected the F-Area cooling tower data to produce a database suitable for validation of a cooling tower model used by one of SRNL's customer agencies. SRNL considers the data to be accurate enough for use in a model validation effort. Also, the thermal images of the cooling tower decks and throats combined with the temperature measurements inside the tower provide valuable information about the appearance of cooling towers as a function of fan operating status and time of day.« less
NASA Astrophysics Data System (ADS)
Parlange, M. B.; Giometto, M. G.; Meneveau, C. V.; Fang, J.; Christen, A.
2013-12-01
Local turbulent kinetic energy (TKE) in the Urban Canopy Layer (UCL) is highly dependent on the actual configuration of obstacles relative to mean wind and stability. For many applications, building-resolving information is neither required nor feasible, and simply beyond the numerical capabilities of operational systems. Common urban canopy parameterizations (UCP) used in dispersion and mesoscale forecasting models hence rely on a horizontally averaged approach, where the UCL is represented as a 1D column, often for simplified geometries such as infinite street canyons. We use Large Eddy Simulations (LES) of the airflow over and within a realistic urban geometry in the city of Basel, Switzerland to determine all terms of the TKE budget in order to guide and validate current approaches used in UCPs. A series of high-resolution LES runs of the fully developed flow are performed in order to characterize the TKE budget terms in a horizontally averaged frame of view for various directions of the approaching flow under neutral conditions. Equations are solved on a regular domain with a horizontal resolution of 2 m. A Lagrangian scale-dependent LES model is adopted to parametrize the subgrid-scale stresses and buildings are taken into account adopting an immersed boundary approach with the geometry taken from a highly accurate digital building model. The modeled (periodic) domain is centered on the location of a 32 m tall tower, where measurements of turbulence were performed, during the BUBBLE program in 2001/02 (Rotach et al., Theor. Appl. Clim., 82, 231-261, 2005). Selected terms of the TKE budget were inferred from six levels of ultrasonic anemometer measurements operated over nearly a full year between ground level and two times the mean building height. This contribution answers the questions: (1) How well do TKE budget terms calculated by the LES at the exact tower location match the single point measurements on the tower under comparable conditions? (2) How representative are the single-point measurements at the tower-location compared to the horizontally-averaged TKE budget in the entire urban domain? (3) How important are non-measurable terms of the TKE budget (wake production, dispersive transport, pressure transport) under the current real urban geometry? Our results show good statistical agreement between tower measurements and numerically resolved quantities, validating the model and confirming our immersed boundary approach in the LES a valuable tool to study turbulence and dispersion within real UCLs. Turbulent kinetic energy (TKE) in the UCL is primarily produced at roof-level, and turbulence is transported down into the cavities of the urban canopy (street canyons, backyards). From our results it is also clear how tower measurements cannot be used to quantify all terms in a horizontally-averaged view and the non-measured dispersive terms are important in a real canopy.
Microgravity Propellant Tank Geyser Analysis and Prediction
NASA Technical Reports Server (NTRS)
Thornton, Randall J.; Hochstein, John I.; Turner, James E. (Technical Monitor)
2001-01-01
An established correlation for geyser height prediction of an axial jet inflow into a microgravity propellant tank was analyzed and an effort to develop an improved correlation was made. The original correlation, developed using data from ethanol flow in small-scale drop tower tests, uses the jet-Weber number and the jet-Bond number to predict geyser height. A new correlation was developed from the same set of experimental data using the jet-Weber number and both the jet-Bond number and tank-Bond number to describe the geyser formation. The resulting correlation produced nearly a 40% reduction in geyser height predictive error compared to the original correlation with experimental data. Two additional tanks were computationally modeled in addition to the small-scale tank used in the drop tower testing. One of these tanks was a 50% enlarged small-scale tank and the other a full-scale 2 m radius tank. Simulations were also run for liquid oxygen and liquid hydrogen. Results indicated that the new correlation outperformed the original correlation in geyser height prediction under most circumstances. The new correlation has also shown a superior ability to recognize the difference between flow patterns II (geyser formation only) and III (pooling at opposite end of tank from the bulk fluid region).
5. VIEW NORTHWEST FROM LEFT TO RIGHT: COLD CALIBRATION OBSERVATION ...
5. VIEW NORTHWEST FROM LEFT TO RIGHT: COLD CALIBRATION OBSERVATION BUNKER BACKGROUND, COLD CALIBRATION TOWER. - Marshall Space Flight Center, East Test Area, Cold Calibration Test Stand, Huntsville, Madison County, AL
Microgravity experiment study on the vane type surface tension tank
NASA Astrophysics Data System (ADS)
Kang, Qi; Duan, Li; Rui, Wei
Having advantages of low cost, convenience and high level of microgravity, the drop tower has become a significant microgravity experiment facility. National Microgravity Laboratory/CAS(NMLC) drop tower has 3.5s effective microgravity time, meanwhile the level of microgravity can reach 10 (-5) g. And the impact acceleration is less than 15g in the recovery period. The microgravity experiments have been conducted on the scaling model of vane type surface tension tank in NMLC’s drop tower. The efficiency of Propellant Management Devices (PMDs) was studied, which focus on the effects of Propellant Management Devices (PMDs), numbers of PMDs, contact angle, and liquid viscosity on the flow rate. The experimental results shown that the numbers of PMDs have little or no effect on the flow rate while the liquid is sufficient. The experiments about the influence of different charging ratio have been carried out while tank is placed positively and reversely, and we find the charging ratio has less effect on the capillary flow rate when the charging ratio is greater than 2%.
Computational Aerodynamic Analysis of Offshore Upwind and Downwind Turbines
Zhao, Qiuying; Sheng, Chunhua; Afjeh, Abdollah
2014-01-01
Aerodynamic interactions of the model NREL 5 MW offshore horizontal axis wind turbines (HAWT) are investigated using a high-fidelity computational fluid dynamics (CFD) analysis. Four wind turbine configurations are considered; three-bladed upwind and downwind and two-bladed upwind and downwind configurations, which operate at two different rotor speeds of 12.1 and 16 RPM. In the present study, both steady and unsteady aerodynamic loads, such as the rotor torque, blade hub bending moment, and base the tower bending moment of the tower, are evaluated in detail to provide overall assessment of different wind turbine configurations. Aerodynamic interactions between the rotor and tower are analyzed,more » including the rotor wake development downstream. The computational analysis provides insight into aerodynamic performance of the upwind and downwind, two- and three-bladed horizontal axis wind turbines.« less
Vertical divergence of fogwater fluxes above a spruce forest
NASA Astrophysics Data System (ADS)
Burkard, R.; Eugster, W.; Wrzesinsky, T.; Klemm, O.
Two almost identical eddy covariance measurement setups were used to measure the fogwater fluxes to a forest ecosystem in the "Fichtelgebirge" mountains (Waldstein research site, 786 m a.s.l.) in Germany. During the first experiment, an intercomparison was carried out with both setups running simultaneously at the same measuring height on a meteorological tower, 12.5 m above the forest canopy. The results confirmed a close agreement of the turbulent fluxes between the two setups, and allowed to intercalibrate liquid water content (LWC) and gravitational fluxes. During the second experiment, the setups were mounted at a height of 12.5 and 3 m above the canopy, respectively. For the 22 fog events, a persistent negative flux divergence was observed with a greater downward flux at the upper level. To extrapolate the turbulent liquid water fluxes measured at height z to the canopy of height hc, a conversion factor 1/[1+0.116( z- hc)] was determined. For the fluxes of nonvolatile ions, no such correction is necessary since the net evaporation of the fog droplets appears to be the primary cause of the vertical flux divergence. Although the net evaporation reduces the liquid water flux reaching the canopy, it is not expected to change the absolute amount of ions dissolved in fogwater.
Tower Shielding Reactor II design and operation report: Vol. 2. Safety Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holland, L. B.; Kolb, J. O.
1970-01-01
Information on the Tower Shielding Reactor II is contained in the TSR-II Design and Operation Report and in the Tower Shielding Facility Manual. The TSR-II Design and Operating Report consists of three volumes. Volume 1 is Descriptions of the Tower Shielding Reactor II and Facility; Volume 2 is Safety analysis of the Tower Shielding Reactor II; and Volume 3 is the Assembly and Testing of the Tower Shielding Reactor II Control Mechanism Housing.
COOLING TOWER PUMP HOUSE, TRA606. THREE OF SIX SECTIONS OF ...
COOLING TOWER PUMP HOUSE, TRA-606. THREE OF SIX SECTIONS OF COOLING TOWER ARE VISIBLE ABOVE RAILING. PUMP HOUSE IN FOREGROUND IS ON SOUTH SIDE OF COOLING TOWER. NOTE THREE PIPES TAKING WATER FROM PUMP HOUSE TO HOT DECK OF COOLING TOWER. EMERGENCY WATER SUPPLY TOWER IS ALSO IN VIEW. INL NEGATIVE NO. 6197. Unknown Photographer, 6/27/1952 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Chen, Ming-liang; Wang, Gang-yi; Chen, Min; Zhou, Hai-jian; Shao, Zhu-jun; Zhang, Xi; Wu, Fan
2010-07-01
To investigate the genotypic characteristics and persistence of Legionella pulsed-field gel electrophoresis (PFGE) patterns in 16 air-conditioner cooling towers in six different public sites of Shanghai. From May to October, continuous sampling was operated once per month in 2007. Legionella strains isolated from the 16 cooling towers were confirmed by serological and latex agglutination. PFGE was applied for the fingerprinting of the isolates, while the cluster results of PFGE were analyzed by BioNumerics software. 131 strains of Legionella were isolated, including L. pneumophila, L. bozemanae, L. micdadei and L. anisa. 52 distinguishable PFGE patterns were differentiated among the 16 cooling towers, with 37 patterns were owned by just one cooling tower, which was not shared with other cooling towers, while 15 patterns were shared by more than 2 cooling towers. All the cooling towers had ≥ 2 PFGE patterns, while in 13 cooling towers the same PFGE patterns were recovered during the six months. From June to October of 2007, 18 strains of Legionella belonging to the PFGE pattern of LPAs.SH0078 were isolated continuously from 6 cooling towers. This study demonstrated great genotypic diversity and complexity of Legionella in cooling towers. Persistence of the PFGE patterns was observed in 81.25% of the cooling towers. The PFGE pattern of LPAs. SH0078 was distributed widely, suggesting it might be the dominate strain in Shanghai.
Liu, Xinjie; Liu, Liangyun; Hu, Jiaochan; Du, Shanshan
2017-01-01
The measurement of solar-induced chlorophyll fluorescence (SIF) is a new tool for estimating gross primary production (GPP). Continuous tower-based spectral observations together with flux measurements are an efficient way of linking the SIF to the GPP. Compared to conical observations, hemispherical observations made with cosine-corrected foreoptic have a much larger field of view and can better match the footprint of the tower-based flux measurements. However, estimating the equivalent radiation transfer path length (ERTPL) for hemispherical observations is more complex than for conical observations and this is a key problem that needs to be addressed before accurate retrieval of SIF can be made. In this paper, we first modeled the footprint of hemispherical spectral measurements and found that, under convective conditions with light winds, 90% of the total radiation came from an FOV of width 72°, which in turn covered 75.68% of the source area of the flux measurements. In contrast, conical spectral observations covered only 1.93% of the flux footprint. Secondly, using theoretical considerations, we modeled the ERTPL of the hemispherical spectral observations made with cosine-corrected foreoptic and found that the ERTPL was approximately equal to twice the sensor height above the canopy. Finally, the modeled ERTPL was evaluated using a simulated dataset. The ERTPL calculated using the simulated data was about 1.89 times the sensor’s height above the target surface, which was quite close to the results for the modeled ERTPL. Furthermore, the SIF retrieved from atmospherically corrected spectra using the modeled ERTPL fitted well with the reference values, giving a relative root mean square error of 18.22%. These results show that the modeled ERTPL was reasonable and that this method is applicable to tower-based hemispherical observations of SIF. PMID:28509843
DOE Office of Scientific and Technical Information (OSTI.GOV)
Celis, Gerardo; Mauritz, Marguerite; Bracho, Rosvel
Current and future warming of high-latitude ecosystems will play an important role in climate change through feedbacks to the global carbon cycle. This study compares 6 years of CO 2 flux measurements in moist acidic tundra using autochambers and eddy covariance (Tower) approaches. Here, we found that the tundra was an annual source of CO 2 to the atmosphere as indicated by net ecosystem exchange using both methods with a combined mean of 105 ± 17 g CO 2 C m-2 y-1 across methods and years (Tower 87 ± 17 and Autochamber 123 ± 14). Furthermore, the difference between methodsmore » was largest early in the observation period, with Autochambers indicated a greater CO 2 source to the atmosphere. This discrepancy diminished through time, and in the final year the Autochambers measured a greater sink strength than tower. Active layer thickness was a significant driver of net ecosystem carbon exchange, gross ecosystem primary productivity, and Reco and could account for differences between Autochamber and Tower. The stronger source initially attributed lower summer season gross primary production (GPP) during the first 3 years, coupled with lower ecosystem respiration (Reco) during the first year. The combined suppression of GPP and Reco in the first year of Autochamber measurements could be the result of the experimental setup. Root damage associated with Autochamber soil collar installation may have lowered the plant community's capacity to fix C, but recovered within 3 years. And while this ecosystem was a consistent CO 2 sink during the summer, CO 2 emissions during the nonsummer months offset summer CO 2 uptake each year.« less
Celis, Gerardo; Mauritz, Marguerite; Bracho, Rosvel; ...
2017-06-28
Current and future warming of high-latitude ecosystems will play an important role in climate change through feedbacks to the global carbon cycle. This study compares 6 years of CO 2 flux measurements in moist acidic tundra using autochambers and eddy covariance (Tower) approaches. Here, we found that the tundra was an annual source of CO 2 to the atmosphere as indicated by net ecosystem exchange using both methods with a combined mean of 105 ± 17 g CO 2 C m-2 y-1 across methods and years (Tower 87 ± 17 and Autochamber 123 ± 14). Furthermore, the difference between methodsmore » was largest early in the observation period, with Autochambers indicated a greater CO 2 source to the atmosphere. This discrepancy diminished through time, and in the final year the Autochambers measured a greater sink strength than tower. Active layer thickness was a significant driver of net ecosystem carbon exchange, gross ecosystem primary productivity, and Reco and could account for differences between Autochamber and Tower. The stronger source initially attributed lower summer season gross primary production (GPP) during the first 3 years, coupled with lower ecosystem respiration (Reco) during the first year. The combined suppression of GPP and Reco in the first year of Autochamber measurements could be the result of the experimental setup. Root damage associated with Autochamber soil collar installation may have lowered the plant community's capacity to fix C, but recovered within 3 years. And while this ecosystem was a consistent CO 2 sink during the summer, CO 2 emissions during the nonsummer months offset summer CO 2 uptake each year.« less
78 FR 11146 - Utility Scale Wind Towers From the People's Republic of China: Antidumping Duty Order
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-15
... DEPARTMENT OF COMMERCE International Trade Administration [A-570-981] Utility Scale Wind Towers...''), the Department is issuing an antidumping duty order on utility scale wind towers (``wind towers... investigation of wind towers from the PRC.\\1\\ On February 8, 2013, the ITC notified the Department of its...
Applied Meteorology Unit (AMU)
NASA Technical Reports Server (NTRS)
Bauman, William; Crawford, Winifred; Watson, Leela; Wheeler, Mark
2011-01-01
This Quarter's Highlights incllude: completion of the second phase of verifying the performance of the MesoNAM weather model at Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS). (1) The data was delivered to the 45th Weather Squadron (45 WS) and the final report was distributed (2) Staff completed modifying and updating lightning c1imatologies for KSC/CCAFS and other airfields around central Florida. We delivered the tool to the National Weather Service in Melbourne and 45 WS and distributed the final report (3) Staff completed modifying the AMU peak wind tool by analyzing wind tower data to determine peak wind behavior during times of onshore and offshore flow. This was delivered the to the 45 WS and distributed the final report.
The Sagrada Familia Cathedral where Gaudi envisaged his bell music
NASA Astrophysics Data System (ADS)
Yoshikawa, Shigeru; Narita, Takafumi
2004-05-01
The Sagrada Familia Cathedral in Barcelona, Spain was constructed in 1882. According to Antoni Gaudi, who worked over its grand plan, the Cathedral was supposed to be a huge musical instrument as a whole in the event of completion. As as result, the music of bells was expected to echo through the air of Barcelona from the belfries. However, Gaudi's true intention cannot be exactly known because the materials prepared by him were destroyed by war fire. If his idea of the Sagrada Familia as an architechtural music instrument is true, an acoustical balance should be considered between the roles of the Cathedral: bell music from the belfries and quiet service in the chapel. Basic structure of the Sagrada Familia seems to be an ensemble of twin towers. Following such speculation, we made a simplified acrylic 1/25-scale model of the lower structure of a twin tower located at the left side of the Birth Gate. The higher structure of this twin tower corresponds to the pinnacle where the bells should be arranged. The lower structure (about 43 m in actual height) has five passages connecting two towers. One of two towers includes five or six tandem columns whose ends are both squeezed to about 1.5 m in diameter. These columns seem to function as a kind of muffler. The location and shape of the roof over the nave is indefinite and tentatively supposed at the top of the lower structure. Based on our scale model, acoustical characteristics of the lower twin-tower structure as a muffler and acoustical differences between the exterior field and nave field will be reported and discussed.
Legionella in industrial cooling towers: monitoring and control strategies.
Carducci, A; Verani, M; Battistini, R
2010-01-01
Legionella contamination of industrial cooling towers has been identified as the cause of sporadic cases and outbreaks of legionellosis among people living nearby. To evaluate and control Legionella contamination in industrial cooling tower water, microbiological monitoring was carried out to determine the effectiveness of the following different disinfection treatments: (i) continuous chlorine concentration of 0.01 ppm and monthly chlorine shock dosing (5 ppm) on a single cooling tower; (ii) continuous chlorine concentration of 0.4 ppm and monthly shock of biocide P3 FERROCID 8580 (BKG Water Solution) on seven towers. Legionella spp. and total bacterial count (TBC) were determined 3 days before and after each shock dose. Both strategies demonstrated that when chlorine was maintained at low levels, the Legionella count grew to levels above 10(4) CFU l(-1) while TBC still remained above 10(8 )CFU l(-1). Chlorine shock dosing was able to eliminate bacterial contamination, but only for 10-15 days. Biocide shock dosing was also insufficient to control the problem when the disinfectant concentration was administered at only one point in the plant and at the concentration of 30 ppm. On the other hand, when at a biocide concentration of 30 or 50 ppm was distributed throughout a number of points, depending on the plant hydrodynamics, Legionella counts decreased significantly and often remained below the warning limit. Moreover, the contamination of water entering the plant and the presence of sediment were also important factors for Legionella growth. For effective decontamination of outdoor industrial cooling towers, disinfectants should be distributed in a targeted way, taking into account the possible sources of contamination. The data of the research permitted to modify the procedure of disinfection for better reduce the water and aerosol contamination and consequently the exposure risk.
Memory dysfunction and autonomic neuropathy in non-insulin-dependent (type 2) diabetic patients.
Zaslavsky, L M; Gross, J L; Chaves, M L; Machado, R
1995-11-01
Considering the nervous system as a unit, it might be expected that diabetic patients with autonomic neuropathy could have a central abnormality expressed as cognitive dysfunction. To determine whether autonomic neuropathy is independently associated with cognitive dysfunction, we studied a cross-section of 20 non-insulin-dependent diabetic patients with autonomic neuropathy (14 males and six females; age (mean) = 60 + or - 1 years); 29 non-insulin-dependent diabetic patients without autonomic neuropathy (14 males and 15 females; age = 59 + or - 1 years) and 34 non-diabetic patients (10 males and 24 females; age = 58 + or - 1 years), matched by age, education and duration of disease. Cognitive function was evaluated by tests of immediate, recent and remote memory: verbal (digit span; word span) and visual (recognition of towers and famous faces). Diabetic patients with autonomic neuropathy scored (median) lower in visual memory tests than diabetic patients without autonomic neuropathy and controls (towers immediate = 5 versus 7 and 6; towers recent = 4 versus 6 and 6; faces = 16 versus 18 and 18; respectively; Kruskal-Wallis; P < 0.05). There was no difference in verbal memory performance (Kruskal-Wallis; P > 0.05). Entering age, education, duration of disease and fasting plasma glucose in a stepwise multiple regression, the performance in these tests remained associated with autonomic neuropathy (towers immediate, P = 0.0054, partial r2 = 0.166; towers recent, P = 0.0076, partial r2 = 0.163). Scores in visual tests correlated negatively with the number of abnormal cardiovascular tests (faces, r = -0.25; towers recent, r = -0.24; Spearman; P < 0.05). Decreased visual cognitive function in non-insulin-dependent diabetic patients is associated with the presence and degree of autonomic neuropathy.
Fluid-structure interaction modeling of wind turbines: simulating the full machine
NASA Astrophysics Data System (ADS)
Hsu, Ming-Chen; Bazilevs, Yuri
2012-12-01
In this paper we present our aerodynamics and fluid-structure interaction (FSI) computational techniques that enable dynamic, fully coupled, 3D FSI simulation of wind turbines at full scale, and in the presence of the nacelle and tower (i.e., simulation of the "full machine"). For the interaction of wind and flexible blades we employ a nonmatching interface discretization approach, where the aerodynamics is computed using a low-order finite-element-based ALE-VMS technique, while the rotor blades are modeled as thin composite shells discretized using NURBS-based isogeometric analysis (IGA). We find that coupling FEM and IGA in this manner gives a good combination of efficiency, accuracy, and flexibility of the computational procedures for wind turbine FSI. The interaction between the rotor and tower is handled using a non-overlapping sliding-interface approach, where both moving- and stationary-domain formulations of aerodynamics are employed. At the fluid-structure and sliding interfaces, the kinematic and traction continuity is enforced weakly, which is a key ingredient of the proposed numerical methodology. We present several simulations of a three-blade 5~MW wind turbine, with and without the tower. We find that, in the case of no tower, the presence of the sliding interface has no effect on the prediction of aerodynamic loads on the rotor. From this we conclude that weak enforcement of the kinematics gives just as accurate results as the strong enforcement, and thus enables the simulation of rotor-tower interaction (as well as other applications involving mechanical components in relative motion). We also find that the blade passing the tower produces a 10-12 % drop (per blade) in the aerodynamic torque. We feel this finding may be important when it comes to the fatigue-life analysis and prediction for wind turbine blades.
Sustained Accelerated Idioventricular Rhythm in a Centrifuge-Simulated Suborbital Spaceflight.
Suresh, Rahul; Blue, Rebecca S; Mathers, Charles; Castleberry, Tarah L; Vanderploeg, James M
2017-08-01
Hypergravitational exposures during human centrifugation are known to provoke dysrhythmias, including sinus dysrhythmias/tachycardias, premature atrial/ventricular contractions, and even atrial fibrillations or flutter patterns. However, events are generally short-lived and resolve rapidly after cessation of acceleration. This case report describes a prolonged ectopic ventricular rhythm in response to high G exposure. A previously healthy 30-yr-old man voluntarily participated in centrifuge trials as a part of a larger study, experiencing a total of 7 centrifuge runs over 48 h. Day 1 consisted of two +Gz runs (peak +3.5 Gz, run 2) and two +Gx runs (peak +6.0 Gx, run 4). Day 2 consisted of three runs approximating suborbital spaceflight profiles (combined +Gx and +Gz). Hemodynamic data collected included blood pressure, heart rate, and continuous three-lead electrocardiogram. Following the final acceleration exposure of the last Day 2 run (peak +4.5 Gx and +4.0 Gz combined, resultant +6.0 G), during a period of idle resting centrifuge activity (resultant vector +1.4 G), the subject demonstrated a marked change in his three-lead electrocardiogram from normal sinus rhythm to a wide-complex ectopic ventricular rhythm at a rate of 91-95 bpm, consistent with an accelerated idioventricular rhythm (AIVR). This rhythm was sustained for 2 m, 24 s before reversion to normal sinus. The subject reported no adverse symptoms during this time. While prolonged, the dysrhythmia was asymptomatic and self-limited. AIVR is likely a physiological response to acceleration and can be managed conservatively. Vigilance is needed to ensure that AIVR is correctly distinguished from other, malignant rhythms to avoid inappropriate treatment and negative operational impacts.Suresh R, Blue RS, Mathers C, Castleberry TL, Vanderploeg JM. Sustained accelerated idioventricular rhythm in a centrifuge-simulated suborbital spaceflight. Aerosp Med Hum Perform. 2017; 88(8):789-793.
Technology to Facilitate the Use of Impaired Waters in Cooling Towers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Colborn, Robert
The project goal was to develop an effective silica removal technology and couple that with existing electro-dialysis reversal (EDR) technology to achieve a cost effective treatment for impaired waters to allow for their use in the cooling towers of coal fired power plants. A quantitative target of the program was a 50% reduction in the fresh water withdrawal at a levelized cost of water of $3.90/Kgal. Over the course of the program, a new molybdenum-modified alumina was developed that significantly outperforms existing alumina materials in silica removal both kinetically and thermodynamically. The Langmuir capacity is 0.11g silica/g adsorbent. Moreover, amore » low cost recycle/regeneration process was discovered to allow for multiple recycles with minimal loss in activity. On the lab scale, five runs were carried out with no drop in performance between the second and fifth run in ability to absorb the silica from water. The Mo-modified alumina was successfully prepared on a multiple kilogram scale and a bench scale model column was used to remove 100 ppm of silica from 400 liters of simulated impaired water. Significant water savings would result from such a process and the regeneration process could be further optimized to reduce water requirements. Current barriers to implementation are the base cost of the adsorbent material and the fine powder form that would lead to back pressure on a large column. If mesoporous materials become more commonly used in other areas and the price drops from volume and process improvements, then our material would also lower in price because the amount of molybdenum needed is low and no additional processing is required. There may well be engineering solutions to the fine powder issue; in a simple concept experiment, we were able to pelletize our material with Boehmite, but lost performance due to a dramatic decrease in surface area.« less
NASA Astrophysics Data System (ADS)
Gallant, Joseph
2002-02-01
The distinctive shape of the Eiffel Tower is based on simple physics and is designed so that the maximum torque created by the wind is balanced by the torque due to the Tower's weight. We use this idea to generate an equation for the shape of the Tower. The solution depends only on the width of the base and the maximum wind pressure. We parametrize the wind pressure and reproduce the shape of the Tower. We also discuss some of the Tower's interesting history and characteristics.
THE TOWER HOUSE, LOOKING WEST. The tower house provided a ...
THE TOWER HOUSE, LOOKING WEST. The tower house provided a water tank on the second floor that gravity fed water to the Kineth house and farm buildings. The one-story addition to the west of the tower provided workshop space. The hog shed is seen on the left of the image and the concrete foundation of the upright silo is in the foreground on the right. - Kineth Farm, Tower House, 19162 State Route 20, Coupeville, Island County, WA
2011-07-08
CAPE CANAVERAL, Fla. -- Media from around the globe gather on the grounds of the Press Site at NASA's Kennedy Space Center in Florida to photograph and cover the prelaunch activities and lift off of space shuttle Atlantis on its STS-135 mission to the International Space Station. Seen towering above is the massive Vehicle Assembly Building. Satellite news trucks, trailers and automobiles can be seen in the parking lot with the massive Vehicle Assembly Building towering above. Atlantis began its final flight, with Commander Chris Ferguson, Pilot Doug Hurley and Mission Specialists Sandy Magnus and Rex Walheim on board, at 11:29 a.m. EDT July 8 to deliver the Raffaello multi-purpose logistics module packed with supplies and spare parts to the station. Also in Atlantis' payload bay is the Robotic Refueling Mission experiment that will investigate the potential for robotically refueling existing satellites in orbit. In addition, Atlantis will return with a failed ammonia pump module to help NASA better understand the failure mechanism and improve pump designs for future systems. STS-135 is the 33rd flight of Atlantis, the 37th shuttle mission to the space station, and the 135th and final mission of NASA's Space Shuttle Program. For more information, visit www.nasa.gov/mission_pages/shuttle/shuttlemissions/sts135/index.html. Photo credit: NASA/Jim Grossmann
2003-08-14
KENNEDY SPACE CENTER, FLA. - In the mobile service tower on Launch Pad 17-B, Cape Canaveral Air Force Station, the Space Infrared Telescope Facility (SIRTF) waits for encapsulation. SIRTF will obtain images and spectra by detecting the infrared energy, or heat, radiated by objects in space. Consisting of a 0.85-meter telescope and three cryogenically cooled science instruments, SIRTF will be the largest infrared telescope ever launched into space. It is the fourth and final element in NASA’s family of orbiting “Great Observatories.” Its highly sensitive instruments will give a unique view of the Universe and peer into regions of space that are hidden from optical telescopes.
5. ROOFTOPS, ISHERWOOD HALL (BUILDING NO. 104), GRIFFIN (BUILDING NO. ...
5. ROOFTOPS, ISHERWOOD HALL (BUILDING NO. 104), GRIFFIN (BUILDING NO. 110), MELVILLE HALL (BUILDING NO. 116) LOOKING WEST FROM CLOCK TOWER OF MAHAN HALL - U.S. Naval Academy, Annapolis, Anne Arundel County, MD
Vogt, R.
2016-10-05
We make a systematic study of the modifications of and production in p+Pb collisions atmore » $$\\sqrt{s}$$$_ {NN}$$ = 5 TeV at the LHC. Here, we compare the uncertainties in the EPS09 shadowing parameterization to the calculated mass and scale uncertainties obtained employing the EPS09 NLO central set. We study the dependence of the results on the proton parton density and the choice of the nuclear modifications. We check whether the results obtained are consistent at leading and next-to-leading order. The calculations are compared to the available ALICE and LHCb data on the nuclear modification factors, R pA (y) and R pA (p T) , as well as the forward-backward asymmetries, R FB (y) and R FB (p T) . Finally, we make predictions for the next Pb+Pb run at $$\\sqrt{s}$$$_ {NN}$$ = 5.1 TeV in Run 2 of the LHC.« less
On the spatial distribution and evolution of ultrafine particles in Barcelona
NASA Astrophysics Data System (ADS)
Dall'Osto, M.; Querol, X.; Alastuey, A.; O'Dowd, C.; Harrison, R. M.; Wenger, J.; Gómez-Moreno, F. J.
2013-01-01
Sources and evolution of ultrafine particles were investigated both horizontally and vertically in the large urban agglomerate of Barcelona, Spain. Within the SAPUSS project (Solving Aerosol Problems by Using Synergistic Strategies), a large number of instruments was deployed simultaneously at different monitoring sites (road, two urban background, regional background, urban tower 150 m a.s.l., urban background tower site 80 m a.s.l.) during a 4 week period in September-October 2010. Particle number concentrations (N>5 nm) are highly correlated with black carbon (BC) at all sites only under strong vehicular traffic influences. By contrast, under cleaner atmospheric conditions (low condensation sink, CS) such correlation diverges towards much higher N/BC ratios at all sites, indicating additional sources of particles including secondary production of freshly nucleated particles. Size-resolved aerosol distributions (N10-500) as well as particle number concentrations (N>5 nm) allow us to identify three types of nucleation and growth events: (1) a regional type event originating in the whole study region and impacting almost simultaneously the urban city of Barcelona and the surrounding urban background area; (2) a regional type event impacting only the regional background area but not the urban agglomerate; (3) an urban type event which originates only within the city centre but whose growth continues while transported away from the city to the regional background. Furthermore, during these clean air days, higher N are found at tower level than at ground level only in the city centre whereas such a difference is not so pronounced at the remote urban background tower. In other words, this study suggests that the column of air above the city ground level possesses the optimal combination between low CS and high vapour source, hence enhancing the concentrations of freshly nucleated particles. By contrast, within stagnant polluted atmospheric conditions, higher N and BC concentrations are always measured at ground level relative to tower level at all sites. Our study suggests that the city centre of Barcelona is a source of non-volatile traffic primary particles (29-39% of N>5 nm), but other sources, including secondary freshly nucleated particles contribute up to 61-71% of particle number (N>5 nm) at all sites. We suggest that organic compounds evaporating from freshly emitted traffic particles are a possible candidate for new particle formation within the city and urban plume.
Development of Meteorological Towers Using Advanced Composite Materials
NASA Astrophysics Data System (ADS)
Alshurafa, Sami A.
The research program involved both numerical and experimental work. The numerical analysis was conducted to simulate the static and dynamic behaviour of the 81 m meteorological FRP guyed tower under wind and ice loading. The FRP tower consisted of 16 segments each made of 3 cells connected together to form an equilateral triangle having equal sides of 450 mm. The segments were interconnected using internal sleeves. Various non-linear finite element models were developed to study a number of design parameters for the 81 m FRP tower such as, different laminates containing a variety of stacking sequences of laminate orientations with various thicknesses, different cable diameters, and appropriate guy cable spacing levels. The effect of pre-stressing the guy cables up to 10 % of their breaking strength was investigated. The effect of fibre volume fraction on the design of the FRP tower was also examined. Furthermore, an 8.6 m FRP tower segment was designed using the finite element analysis and subject to the same loading conditions experienced by the bottom section of the 81 m FRP tower. A modal analysis was carried out for both the 8.6 m FRP tower segment with and without a mass on the top as well as for the 81 m FRP guyed tower to evaluate the vibration performance of these towers. The experimental work involved extensive material testing to define the material properties for use in the analysis of the 81 m FRP tower. It also involved the design and fabrication of a special collapsible mandrel for fabricating the FRP cells for the 8.6 m tower segment. The 8.6 m tower was tested horizontally under static lateral loading to 80 % of its estimated failure load using a "whiffle tree" arrangement, in order to simulate a uniformly distributed wind loading. Later, the same FRP tower was erected in a vertical position and was tested with and without a mass on top under dynamic loading to obtain the natural frequencies. Lastly, a comparative study was conducted between two 81 m FRP towers having different fibre volume fractions and a steel tower having a circular cross section.
Variability in perceived tilt during a roll plane canal-otolith conflict in a gondola centrifuge.
Tribukait, Arne; Bergsten, Eddie; Eiken, Ola
2013-11-01
During a simulated coordinated turn in a gondola centrifuge, the perceived roll-tilt, quantified as the subjective visual horizontal (SVH), may differ tenfold between individuals. One aim of this study was to discern whether this variability reflects real individual characteristics or is due to noise or day-to-day variation. We also wanted to establish whether there are any habituation or learning effects of the centrifuge test. In nine nonpilots (NP) and nine student pilots (SP), with a flight experience of 150 h, the SVH was measured using an adjustable luminous line in darkness. At two test occasions (T1, T2) (interval 5-14 d) subjects underwent two runs (R1, R2; acceleration to 2 G in 10 s, gondola inclination 60 degrees, 5 min at 2 G, deceleration to 1 g in 10 s, interval between runs 5 min) in a centrifuge (r = 9.1 m). Initial and final SVH was determined for each individual run. Acceleration of the centrifuge induced a tilt of the SVH. At T1 R1, this SVH tilt was, in NP, initially 24 +/- 18 degrees and finally 8 +/- 10 degrees. The corresponding values for SP were 28 +/- 18 degrees and 31 +/- 33 degrees. The SVH tilt was slightly larger at R2 than at R1. There was no difference between T1 and T2. Reliability coefficients ranged between 0.86 and 0.98 for NP and between 0.78 and 0.99 for SP. The large interindividual variability combined with a very high reproducibility suggests the existence of persistent individual characteristics in the perception of complex vestibular stimuli. Habituation or learning effects of gondola centrifugation appears to be small.
69. INTERIOR VIEW OF THE ABSORPTION TOWER BUILDING, ABSORPTION TOWER ...
69. INTERIOR VIEW OF THE ABSORPTION TOWER BUILDING, ABSORPTION TOWER UNDER CONSTRUCTION. (DATE UNKNOWN). - United States Nitrate Plant No. 2, Reservation Road, Muscle Shoals, Muscle Shoals, Colbert County, AL
Method and system for simulating heat and mass transfer in cooling towers
Bharathan, Desikan; Hassani, A. Vahab
1997-01-01
The present invention is a system and method for simulating the performance of a cooling tower. More precisely, the simulator of the present invention predicts values related to the heat and mass transfer from a liquid (e.g., water) to a gas (e.g., air) when provided with input data related to a cooling tower design. In particular, the simulator accepts input data regarding: (a) cooling tower site environmental characteristics; (b) cooling tower operational characteristics; and (c) geometric characteristics of the packing used to increase the surface area within the cooling tower upon which the heat and mass transfer interactions occur. In providing such performance predictions, the simulator performs computations related to the physics of heat and mass transfer within the packing. Thus, instead of relying solely on trial and error wherein various packing geometries are tested during construction of the cooling tower, the packing geometries for a proposed cooling tower can be simulated for use in selecting a desired packing geometry for the cooling tower.
1. Light tower/keeper's house and abandoned light tower, view northwest, ...
1. Light tower/keeper's house and abandoned light tower, view northwest, south southeast and east northeast sides - Matinicus Rock Light Station, Matinicus Island, on Matinicus Rock, Matinicus, Knox County, ME
2. Abandoned light tower and keeper's house/light tower, view southeast, ...
2. Abandoned light tower and keeper's house/light tower, view southeast, north northwest and west southwest sides - Matinicus Rock Light Station, Matinicus Island, on Matinicus Rock, Matinicus, Knox County, ME
NASA Technical Reports Server (NTRS)
Burley, R. R.; Savino, J. M.; Wagner, L. H.; Diedrich, J. H.
1979-01-01
Wind speed profile measurements to measure the effect of a wind turbine tower on the wind velocity are presented. Measurements were made in the wake of scale models of the tower and in the wake of certain full scale components to determine the magnitude of the speed reduction (tower shadow). Shadow abatement techniques tested on the towers included the removal of diagonals, replacement of diagonals and horizontals with round cross section members, installation of elliptical shapes on horizontal members, installation of airfoils on vertical members, and application of surface roughness to vertical members.
The new Drop Tower catapult system
NASA Astrophysics Data System (ADS)
von Kampen, Peter; Kaczmarczik, Ulrich; Rath, Hans J.
2006-07-01
The Center of Applied Space Technology and Microgravity (ZARM) was founded in 1985 as an institute of the University Bremen, which focuses on research on gravitational and space-related phenomena. In 1988, the construction of the "Drop Tower" began. Since then, the eye-catching tower with a height of 146 m and its characteristic glass roof has become the emblem of the technology centre in Bremen. The Drop Tower Bremen provides a facility for experiments under conditions of weightlessness. Items are considered weightless, when they are in "free fall", i.e. moving without propulsion within the gravity field of the earth. The height of the tower limits the simple "free fall" experiment period to max. 4.74 s. With the inauguration of the catapult system in December 2004, the ZARM is entering a new dimension. This world novelty will meet scientists' demands of extending the experiment period up to 9.5 s. Since turning the first sod on May 3rd, 1988, the later installation of the catapult system has been taken into account by building the necessary chamber under the tower. The catapult system is located in a chamber 10 m below the base of the tower. This chamber is almost completely occupied by 12 huge pressure tanks. These tanks are placed around the elongation of the vacuum chamber of the drop tube. In its centre there is the pneumatic piston that accelerates the drop capsule by the pressure difference between the vacuum inside the drop tube and the pressure inside the tanks. The acceleration level is adjusted by means of a servo hydraulic breaking system controlling the piston velocity. After only a quarter of a second the drop capsule achieves its lift-off speed of 175 km/h. With this exact speed, the capsule will rise up to the top of the tower and afterwards fall down again into the deceleration unit which has been moved under the drop tube in the meantime. The scientific advantages of the doubled experiment time are obvious: during almost 10 s of high-quality weightlessness the range of compatible experiments amplifies even more and researchers can observe processes for a longer period of time. Thus, the new earth-bound laboratory of the ZARM offers unique conditions for scientific research. Moreover, it increases the attractiveness of the Drop Tower and contributes an important part to the establishment of the Bremen as an international centre for space technology.
Evaluation of Tower Shadowing on Anemometer Measurements at Los Alamos National Laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bruggeman, David Alan
2016-06-14
The objective of this study is to evaluate the effect of tower shadowing from the meteorology towers at LANL during 2014. This study is in response to the Department of Energy Meteorological Coordinating Council visit in 2015 that recommended an evaluation of any biases in the wind data introduced by the tower and boom alignment at all meteorology towers.
Optimal Inflatable Space Towers with 3 - 100 km Height
NASA Technical Reports Server (NTRS)
Bolonkin, Alexander
2003-01-01
Theory and computations are provided for building inflatable space towers up to one hundred kilometers in height. These towers can be used for tourism, scientific observation of space, observation of the Earth's surface, weather and upper atmosphere, and for radio, television, and communication transmissions. These towers can also be used to launch space ships and Earth satellites. These projects are not expensive and do not require rockets. They require thin strong films composed from artificial fibers and fabricated by current industry. The towers can be built using present technology. The towers can be used (for tourism, communication, etc.) during the construction process and provide self-financing for further construction. The tower design does not require work at high altitudes; all construction can be done at the Earth's surface. The transport system for a tower consists of a small engine (used only for friction compensation) located at the Earth's surface. The tower is separated into sections and has special protection mechanisms in case of damage. Problems involving security, control, repair, and stability of the proposed towers are addressed in other publications. The author is prepared to discuss these and other problems with serious organizations desiring to research and develop these projects.
Recent Results From the NOAA/ESRL GMD Tall Tower Network
NASA Astrophysics Data System (ADS)
Andrews, A. E.; Tans, P. P.; Peters, W.; Hirsch, A.; Sweeney, C.; Petron, G.; Kofler, J.; Zhao, C.; Masarie, K.; Wofsy, S. C.; Matross, D. M.; Mahadevan, P.; Longo, M.; Gerbig, C.; Lin, J. C.
2006-12-01
We will present a summary of new results from NOAA Earth System Research Laboratory`s Tall Tower greenhouse gas monitoring network. The tower network is operated by the Global Monitoring Division, which also maintains the global Cooperative Air Sampling network and a network of aircraft profiling sites over North America. Tall tower CO2 mixing ratio measurements are sensitive to upwind fluxes over scales of hundreds of kilometers, and the primary objective of the tower network is to obtain regionally representative carbon flux estimates for the North American continent. Mixing ratios of CO2 and CO are measured semi-continuously at the towers, and the KWKT-TV tower site near Moody, TX has recently also been equipped with sensors to measure radon and O3. Daily flask samples are collected at the KWKT tower and analyzed for CO2, CO, CH4, SF6, N2O, H2, stable isotopes of CO2 and CH4, COS, and a variety of halocarbon and hydrocarbon species. Daily flask sampling will be implemented at all tower sites within the next few years. We have used the Stochastic Time Inverted Lagrangian Transport (STILT) model to investigate upwind influences on the tower observations. CO measurements provide an indicator of polluted air masses, and we will present a summary of the frequency and origin of pollution events observed at the towers. We will present an analysis of the primary factors contributing to observed CO2 variability along with average seasonal and diurnal cycles of CO2 at the tower sites. Tower measurements are being used to evaluate atmospheric transport models in the context of the Transcom Continuous experiment and are an important constraint for CO2 data assimilation systems that produce regional to global carbon flux estimates with up to weekly resolution.
DETAIL OF VALVE TOWER SHOWING SLUICE GATE ON EAST SIDE ...
DETAIL OF VALVE TOWER SHOWING SLUICE GATE ON EAST SIDE OF TOWER. VIEW FACING WEST - Schofield Barracks Military Reservation, Ku Tree Reservoir, Valve Tower, Kalakoa Stream, East Range, Wahiawa, Honolulu County, HI
Belke, Terry W
2010-01-01
Previous research suggested that allocation of responses on concurrent schedules of wheel-running reinforcement was less sensitive to schedule differences than typically observed with more conventional reinforcers. To assess this possibility, 16 female Long Evans rats were exposed to concurrent FR FR schedules of reinforcement and the schedule value on one alternative was systematically increased. In one condition, the reinforcer on both alternatives was .1 ml of 7.5% sucrose solution; in the other, it was a 30-s opportunity to run in a wheel. Results showed that the average ratio at which greater than 90% of responses were allocated to the unchanged alternative was higher with wheel-running reinforcement. As the ratio requirement was initially increased, responding strongly shifted toward the unchanged alternative with sucrose, but not with wheel running. Instead, responding initially increased on both alternatives, then subsequently shifted toward the unchanged alternative. Furthermore, changeover responses as a percentage of total responses decreased with sucrose, but not wheel-running reinforcement. Finally, for some animals, responding on the increasing ratio alternative decreased as the ratio requirement increased, but then stopped and did not decline with further increments. The implications of these results for theories of choice are discussed. PMID:21451744
Belke, Terry W
2010-09-01
Previous research suggested that allocation of responses on concurrent schedules of wheel-running reinforcement was less sensitive to schedule differences than typically observed with more conventional reinforcers. To assess this possibility, 16 female Long Evans rats were exposed to concurrent FR FR schedules of reinforcement and the schedule value on one alternative was systematically increased. In one condition, the reinforcer on both alternatives was .1 ml of 7.5% sucrose solution; in the other, it was a 30-s opportunity to run in a wheel. Results showed that the average ratio at which greater than 90% of responses were allocated to the unchanged alternative was higher with wheel-running reinforcement. As the ratio requirement was initially increased, responding strongly shifted toward the unchanged alternative with sucrose, but not with wheel running. Instead, responding initially increased on both alternatives, then subsequently shifted toward the unchanged alternative. Furthermore, changeover responses as a percentage of total responses decreased with sucrose, but not wheel-running reinforcement. Finally, for some animals, responding on the increasing ratio alternative decreased as the ratio requirement increased, but then stopped and did not decline with further increments. The implications of these results for theories of choice are discussed.
Project Profile: Hydrogen Fuel Cell Mobile Lighting Tower (HFCML)
NASA Technical Reports Server (NTRS)
McLaughlin, Russell
2013-01-01
NASA is committed to finding innovative solutions that improve the operational performance of ground support equipment while providing environment and cost benefits, as well. Through the Hydrogen Fuel Cell Mobile Lighting Tower (HFCML) project, NASA gained operational exposure to a novel application of high efficiency technologies. Traditionally, outdoor lighting and auxiliary power at security gates, launch viewing sites, fallback areas, outage support, and special events is provided by diesel generators with metal halide lights. Diesel generators inherently contribute to C02, NOx, particulate emissions, and are very noisy. In 2010, engineers from NASA's Technology Evaluation for Environmental Risk Mitigation Principal Center (TEERM) introduced KSC operations to a novel technology for outdoor lighting needs. Developed by a team led by Sandia National Laboratory (SNL), the technology pairs a 5kW hydrogen fuel cell with robust high efficiency plasma lights in a towable trailer. Increased efficiency, in both the fuel cell power source and lighting load, yields longer run times between fueling operations while providing greater auxiliary power. Because of the unit's quiet operation and no exhaust fumes, it is capable of being used indoors and in emergency situations, and meets the needs of all other operational roles for metal halide/diesel generators. The only discharge is some water and warm air. Environmental benefits include elimination of diesel particulate emissions and estimated 73% greenhouse gas emissions savings when the hydrogen source is natural gas (per GREET model). As the technology matures the costs could become competitive for the fuel cell units which are approximately 5 times diesel units. Initial operational . concerns included the hydrogen storage tanks and valves, lightning safety/grounding, and required operating and refueling procedures. TEERM facilitated technical information exchange (design drawings, technical standards, and operations manuals) necessary for KSC hydrogen system experts to approve use of the HFCML unit, including initiating the environmental checklist (i.e. exterior lighting waiver due to sea turtles), and development of operations and maintenance instructions. TEERM worked with SNL to establish a bailment agreement for KSC to utilize a Beta unit as part of normal Center Operations for a period of twelve months.
The Validity and Reliability of an iPhone App for Measuring Running Mechanics.
Balsalobre-Fernández, Carlos; Agopyan, Hovannes; Morin, Jean-Benoit
2017-07-01
The purpose of this investigation was to analyze the validity of an iPhone application (Runmatic) for measuring running mechanics. To do this, 96 steps from 12 different runs at speeds ranging from 2.77-5.55 m·s -1 were recorded simultaneously with Runmatic, as well as with an opto-electronic device installed on a motorized treadmill to measure the contact and aerial time of each step. Additionally, several running mechanics variables were calculated using the contact and aerial times measured, and previously validated equations. Several statistics were computed to test the validity and reliability of Runmatic in comparison with the opto-electronic device for the measurement of contact time, aerial time, vertical oscillation, leg stiffness, maximum relative force, and step frequency. The running mechanics values obtained with both the app and the opto-electronic device showed a high degree of correlation (r = .94-.99, p < .001). Moreover, there was very close agreement between instruments as revealed by the ICC (2,1) (ICC = 0.965-0.991). Finally, both Runmatic and the opto-electronic device showed almost identical reliability levels when measuring each set of 8 steps for every run recorded. In conclusion, Runmatic has been proven to be a highly reliable tool for measuring the running mechanics studied in this work.
133. PARCEL HANDLING SPACE OF POST OFFICE BUILDING, LEVEL 72.5, ...
133. PARCEL HANDLING SPACE OF POST OFFICE BUILDING, LEVEL 72.5, NORTH OF TRUCKING PASSAGE MAIL TRANSPORT AREA, VIEW TO NORTHWEST - Terminal Tower Building, Cleveland Union Terminal, 50 Public Square, Cleveland, Cuyahoga County, OH
Concentrating Solar Power Projects - Jülich Solar Tower | Concentrating
: 1.5 MW Gross: 1.5 MW Status: Operational Start Year: 2008 Do you have more information, corrections : July 31, 2007 Start Production: December 2008 Project Type: Demonstration Participants Developer(s
Bulk Chemical and Hf/W Isotopic Consequences of Lossy Accretion
NASA Astrophysics Data System (ADS)
Dwyer, C. A.; Nimmo, F.; Chambers, J.
2013-12-01
The late stages of planetary accretion involve stochastic, large collisions [1]. Many of these collisions likely resulted in hit-and-run events [2] or erosion of existing bodies' crusts [3] or mantles [4]. Here we present a preliminary investigation into the effects of lossy late-stage accretion on the bulk chemistry and isotopic characteristics of the resulting planets. Our model is composed of two parts: (1) an N-body accretion code [5] tracks the orbital and collisional evolution of the terrestrial bodies, including hit-and-run and fragmentation events; (2) post-processing evolves the chemistry in light of radioactive decay and impact-related mixing and partial equilibration. Sixteen runs were performed using the MERCURY N-body code [5]; each run contained Jupiter and Saturn in their current orbits as well as approx 150 initial bodies. Different collisional outcomes including fragmentation are possible depending on the velocity, angle, mass ratio, and total mass of the impact (modified from [6, 7]). The masses of the core and mantle of each body are tracked throughout the simulation. All bodies are assigned an initial mantle mass fraction, y, of 0.7. We track the Hf and W evolution of these bodies. Radioactive decay occurs between impacts. We calculate the effect of an impact by assuming an idealized model of mixing and partial equilibration [8]. The core equilibration factor is a free parameter; we use 0.4. Partition coefficients are assumed constant. Diversity increases as final mass decreases. The range in final y changes from 0.66-0.72 for approx Earth-mass planets to 0.41-1 for the smallest bodies in the simulation. The scatter in tungsten anomaly increases from 0.79-4.0 for approx Earth-mass to 0.11-18 for the smallest masses. This behavior is similar to that observed in our solar system in terms of both bulk and isotopic chemistry. There is no single impact event which defines the final state of the body, therefore talking about a single, specific age of formation does not make sense. Instead, it must be recognized that terrestrial planet formation occurs over a range of time spanning many tens to perhaps hundreds of millions of years. We are currently performing sensitivity analyses to determine the effect on the tungsten isotopic anomalies of the final bodies. [1] Agnor et al. (1999), Icarus 142, 219-237. [2] Asphaug et al. (2006), Nature 439, 155-160. [3] O'Neill & Palme (2008), Phil Trans R Soc Lond A 366, 4205-4238. [4] Benz et al. (2007), Sp SciRev 132, 189-202. [5] Chambers (2013), Icarus, 224, 43-56. [6] Genda et al. (2012), ApJ 744, 137. [7] Leinhardt & Stewart (2012), ApJ 745, 79. [8] Nimmo et al. (2010), EPSL 292, 363-370.
Effect of solar radiation on the performance of cross flow wet cooling tower in hot climate of Iran
NASA Astrophysics Data System (ADS)
Banooni, Salem; Chitsazan, Ali
2016-11-01
In some cities such as Ahvaz-Iran, the solar radiation is very high and the annual-mean-daily of the global solar radiation is about 17.33 MJ m2 d-1. Solar radiation as an external heat source seems to affect the thermal performance of the cooling towers. Usually, in modeling cooling tower, the effects of solar radiation are ignored. To investigate the effect of sunshade on the performance and modeling of the cooling tower, the experiments were conducted in two different states, cooling towers with and without sunshade. In this study, the Merkel's approach and finite difference technique are used to predict the thermal behavior of cross flow wet cooling tower without sunshade and the results are compared with the data obtained from the cooling towers with and without sunshade. Results showed that the sunshade is very efficient and it reduced the outlet water temperature, the approach and the water exergy of the cooling tower up to 1.2 °C, 15 and 1.1 %, respectively and increased the range and the efficiency of the cooling tower up to 29 and 37 %, respectively. Also, the sunshade decreased the error between the experimental data of the cooling tower with sunshade and the modeling results of the cooling tower without sunshade 1.85 % in average.
AmeriFlux US-Ho1 Howland Forest (main tower)
Hollinger, David [USDA Forest Service; Hollinger, David [USDA Forest Service
2016-01-01
This is the AmeriFlux version of the carbon flux data for the site US-Ho1 Howland Forest (main tower). Site Description - Closed conifer forest, minimal disturbance. References: Fernandez et al. (1993), Canadian Journal of Soil Science 73 317-328. Hollinger et al. (1999), Global Change Biology 5: 891-902. Savage KE, Davidson EA (2001), Global Biogeochemical Cycles 15 337-350. Scott et al. (2004), Environmental Management, Vol. 33, Supplement 1, pp. S9-S22. Hollinger et al. (2004), Global Change Biology 10: 1689-1706.
AmeriFlux US-Ho2 Howland Forest (west tower)
Hollinger, David [USDA Forest Service; Hollinger, David [USDA Forest Service
2016-01-01
This is the AmeriFlux version of the carbon flux data for the site US-Ho2 Howland Forest (west tower). Site Description - Closed conifer forest, minimal disturbance. References: Fernandez et al. (1993), Canadian Journal of Soil Science 73 317-328. Hollinger et al. (1999), Global Change Biology 5: 891-902. Savage KE, Davidson EA (2001), Global Biogeochemical Cycles 15 337-350. Scott et al. (2004), Environmental Management, Vol. 33, Supplement 1, pp. S9-S22. Hollinger et al. (2004), Global Change Biology 10: 1689-1706.
Closeup view, looking toward project north at the south elevation ...
Close-up view, looking toward project north at the south elevation of the tower, and featuring the single-story, wood-frame addition to the east side of the tower. The addition covered the stone-lined, gravity-fed water cistern, and contained a pump (now removed) that lifted water from the cistern into the water tank for use by trains. - East Broad Top Railroad & Company, Water Tank at Coles Station, East Broad Top Railroad & Company (at Milepost 24.3), 0.5 miles east of Coles Valley Road, Saltillo, Huntingdon County, PA
Closeup view, looking toward project south at the north elevation ...
Close-up view, looking toward project south at the north elevation of the tower, and featuring the single-story, wood-frame addition to the east side of the tower. The addition covered the stone-lined, gravity-fed water cistern, and contained a pump (now removed) that lifted water from the cistern into the water tank for use by trains. - East Broad Top Railroad & Company, Water Tank at Coles Station, East Broad Top Railroad & Company (at Milepost 24.3), 0.5 miles east of Coles Valley Road, Saltillo, Huntingdon County, PA
1982-08-01
Deceleration Tower (VDT), shown in Figure 9, was used for this impact test series. This facility consists of a 60 ft vertical steel tower, which supports a...to void prior to entering the test area. A disposable dental bite block (made of Optosil placed over a stainless steel frame) was molded for the...shoulder strap - lap belt configuration (Sections 4D, 5C). 6. Subtolerance human impact tests can be an effective tool in the investi- gation of impact
2. LOOKING WEST FROM THE TOP OF THE WATER TOWER ...
2. LOOKING WEST FROM THE TOP OF THE WATER TOWER AT ROOFTOPS OF INDUSTRIAL SHEDS. BUILDINGS IN THE FOREGROUND INCLUDE THE SHIPPING BAYS OF THE STRUCTURAL MILL AND MAIN ROLL SHOP. BUILDINGS IN THE MIDDLE GROUND INCLUDE PRESS SHOP No. 2, CHIPPING YARD, BLACKSMITH SHOP, AND MACHINE SHOP No. 1. THE TALLEST STRUCTURE IS THE VERTICAL FURNACE BUILDING, AND OPEN HEARTH No. 5 IS IN THE EXTREME BACKGROUND. Jet Lowe, Photographer, 1989. - U.S. Steel Homestead Works, Structural Mill, Along Monongahela River, Homestead, Allegheny County, PA
NASA Astrophysics Data System (ADS)
Visacro, Silverio; Guimaraes, Miguel; Murta Vale, Maria Helena
2017-12-01
Original simultaneous records of currents, close electric field, and high-speed videos of natural negative cloud-to-ground lightning striking the tower of Morro do Cachimbo Station are used to reveal typical features of upward positive leaders before the attachment, including their initiation and mode of propagation. According to the results, upward positive leaders initiate some hundreds of microseconds prior to the return stroke, while a continuous uprising current of about 4 A and superimposed pulses of a few tens amperes flow along the tower. Upon leader initiation, the electric field measured 50 m away from the tower at ground level is about 60 kV/m. The corresponding average field roughly estimated 0.5 m above the tower top is higher than 0.55 MV/m. As in laboratory experiments, the common propagation mode of upward positive leaders is developing continuously, without steps, from their initiation. Unlike downward negative leaders, upward positive leaders typically do not branch off, though they can bifurcate under the effect of a downward negative leader's secondary branch approaching their lateral surface. The upward positive leader's estimated average two-dimensional propagation speed, in the range of 0.06 × 106 to 0.16 × 106 m/s, has the same order of magnitude as that of downward negative leaders. Apparently, the speed tends to increase just before attachment.
3. VIEW NORTHWEST, height finder radar towers, and radar tower ...
3. VIEW NORTHWEST, height finder radar towers, and radar tower (unknown function) - Fort Custer Military Reservation, P-67 Radar Station, .25 mile north of Dickman Road, east of Clark Road, Battle Creek, Calhoun County, MI
NASA Astrophysics Data System (ADS)
Liu, Lingling; Zhang, Xiaoyang; Yu, Yunyue; Donnelly, Alison
2017-02-01
The timing of fall foliage coloration, especially peak coloration, is of great importance to the climate change research community as it has implications for carbon storage in forests. However, its long-term variation and response to climate change are poorly understood. To address this issue, we examined the long-term trends and breakpoints in satellite derived peak coloration onset from 1982 to 2014 using an innovative approach that combines Singular Spectrum Analysis (SSA) with Breaks for Additive Seasonal and Trend (BFAST). The peak coloration trend was then evaluated using both field foliage coloration observations and flux tower measurements. Finally, interannual changes in peak coloration onset were correlated with temperature and precipitation variation. Results showed that temporal trends in satellite-derived peak coloration onset were comparable with both field observations and flux tower measurements of gross primary productivity. Specifically, a breakpoint in long-term peak coloration onset was detected in 25% of pixels which were mainly distributed at latitudes north of 37°N. The breakpoint tended to occur between 1998 and 2004. Peak coloration onset was delayed before the breakpoint while it was transformed to an early trend after the breakpoint in nearly all pixels. The remaining 75% of pixels exhibited monotonic trends, 35% of which revealed a late trend and 40% an early trend. The results indicate that the onset of peak coloration experienced a late trend during the 1980s and 1990s in most deciduous and mixed forests. However, the trend was reversed during the most recent decade when the timing of peak coloration became earlier. The onset of peak coloration was significantly correlated with late summer and autumn temperature in 55.5% of pixels from 1982 to 2014. This pattern of temperature impacts was also verified using field observations and flux tower measurements. In the remaining 44.5% of pixels, 12.2% of pixels showed significantly positive correlation between the onset of peak coloration and cumulative precipitation during late summer and autumn period from 1982 to 2014. Our findings can improve understanding of the impact of changes in autumn phenology on carbon uptake in forests, which in turn facilitate more reliable measures of carbon dynamics in vegetation-climate interactions models.
NASA Astrophysics Data System (ADS)
Hoffmann, Lars; Wu, Xue; Alexander, M. Joan
2018-02-01
Forecasting the intensity of tropical cyclones is a challenging problem. Rapid intensification is often preceded by the formation of "hot towers" near the eyewall. Driven by strong release of latent heat, hot towers are high-reaching tropical cumulonimbus clouds that penetrate the tropopause. Hot towers are a potentially important source of stratospheric gravity waves. Using 13.5 years (2002-2016) of Atmospheric Infrared Sounder observations of stratospheric gravity waves and tropical cyclone data from the International Best Track Archive for Climate Stewardship, we found empirical evidence that stratospheric gravity wave activity is associated with the intensification of tropical cyclones. The Atmospheric Infrared Sounder and International Best Track Archive for Climate Stewardship data showed that strong gravity wave events occurred about twice as often for tropical cyclone intensification compared to storm weakening. Observations of stratospheric gravity waves, which are not affected by obscuring tropospheric clouds, may become an important future indicator of storm intensification.
A comment on towers for windmills. [structural and economic criteria
NASA Technical Reports Server (NTRS)
Budgen, H. P.
1973-01-01
Design considerations for windmill tower structures include the effects of normal wind forces on the rotor and on the tower. Circular tabular or masonry towers present a relatively simple aerodynamic solution. Economic factors establish the tubular tower as superior for small and medium sized windmills. Concrete and standard concrete block designs are cheaper than refabricated steel structures that have to be freighted.
The Device Centric Communication System for 5G Networks
NASA Astrophysics Data System (ADS)
Biswash, S. K.; Jayakody, D. N. K.
2017-01-01
The Fifth Generation Communication (5G) networks have several functional features such as: Massive Multiple Input and Multiple Output (MIMO), Device centric data and voice support, Smarter-device communications, etc. The objective for 5G networks is to gain the 1000x more throughput, 10x spectral efficiency, 100 x more energy efficiency than existing technologies. The 5G system will provide the balance between the Quality of Experience (QoE) and the Quality of Service (QoS), without compromising the user benefit. The data rate has been the key metric for wireless QoS; QoE deals with the delay and throughput. In order to realize a balance between the QoS and QoE, we propose a cellular Device centric communication methodology for the overlapping network coverage area in the 5G communication system. The multiple beacon signals mobile tower refers to an overlapping network area, and a user must be forwarded to the next location area. To resolve this issue, we suggest the user centric methodology (without Base Station interface) to handover the device in the next area, until the users finalize the communication. The proposed method will reduce the signalling cost and overheads for the communication.
Model equations for the Eiffel Tower profile: historical perspective and new results
NASA Astrophysics Data System (ADS)
Weidman, Patrick; Pinelis, Iosif
2004-07-01
Model equations for the shape of the Eiffel Tower are investigated. One model purported to be based on Eiffel's writing does not give a tower with the correct curvature. A second popular model not connected with Eiffel's writings provides a fair approximation to the tower's skyline profile of 29 contiguous panels. Reported here is a third model derived from Eiffel's concern about wind loads on the tower, as documented in his communication to the French Civil Engineering Society on 30 March 1885. The result is a nonlinear, integro-differential equation which is solved to yield an exponential tower profile. It is further verified that, as Eiffel wrote, "in reality the curve exterior of the tower reproduces, at a determined scale, the same curve of the moments produced by the wind". An analysis of the actual tower profile shows that it is composed of two piecewise continuous exponentials with different growth rates. This is explained by specific safety factors for wind loading that Eiffel & Company incorporated in the design of the free-standing tower. To cite this article: P. Weidman, I. Pinelis, C. R. Mecanique 332 (2004).
Tall tower landscape scale N2O flux measurements in a Danish agricultural and urban, coastal area
NASA Astrophysics Data System (ADS)
Ibrom, Andreas; Lequy, Émeline; Loubet, Benjamin; Pilegaard, Kim; Ambus, Per
2015-04-01
Both technical and natural processes emit the greenhouse gas nitrous oxide (N2O) into the atmosphere. The abundant use of nitrogen (N) as fertiliser increases the concentration of reactive nitrogen (Nr) in the atmosphere, the hydrosphere and in the biosphere, i.e. in terrestrial and aquatic ecosystems. Surplus Nr is distributed across linkages to other spheres until most of it is emitted to the atmosphere as NO, N2O or N2. A complete estimate of the effects from human activities on N2O emissions must therefore include all emissions, the direct emissions and the indirect emissions that happen in interlinked spheres. For this it is necessary to assess the fluxes at least at the landscape scale. The episodic nature and the large spatial variability make it difficult to estimate the direct and indirect emissions in a landscape. Modelling requires not only to include the highly variable microbial processes in the ecosystems that produce N2O but as well the accurate simulation of lateral Nr fluxes and their effects on N2O fluxes in places remote from the primary Nr sources. In this context tall tower N2O flux measurements are particularly useful as they integrate over larger areas and can be run, continuously without disturbing the fluxes. On the other hand these measurements can be difficult to interpret due to difficulties to measure the small concentration fluctuations in the atmosphere at small flux rates and to accurately attribute the measured flux at the tower to the area that generates the flux, i.e. the source area. The Technical University of Denmark (DTU) has established eddy covariance N2O flux measurements on a 125 m tall tower at its Risø Campus as part of the EU research infrastructure project the 'Integrated non-CO2 Greenhouse gas Observing System' (InGOS). The eddy covariance system consisted of a N2O/CO quantum cascade laser, Los Gatos, Mountain View, CA, USA and a 3D sonic anemometer (USA-1), Metek, Elmshorn, Germany. The Risø peninsula lies at the eastern coastline of the Roskilde fjord on the Danish island Zealand. The tower is surrounded by the fjord, by agricultural area, forests and, in the South by the urban area of the City of Roskilde. The City of Roskilde operates a waste incinerator and a waste water treatment plant, which drains treated waste water into the fjord. The level of the measured flux values was generally relatively low. Based on the clear definition of the lag time between N2O concentrations and the vertical wind speed, fluxes were measureable over larger periods. The fluxes showed clear directional relationships indicating their large spatial and temporal variability in the landscape. Footprint calculations were performed to attribute source areas to the measured fluxes ...(Kormann and Meixner, 2001; Neftel et al., 2008). The footprint of the flux measurement included areas between 200 m and several kilometres distance from the tower. A preliminary approach was developed to generate monthly maps of N2O fluxes around the tower. Here we present the results from the first seven months of flux measurements. Based on these results we discuss the potential and the limitations of tall tower eddy covariance measurements to estimate maps of N2O fluxes and the integral value of the landscape N2O flux. Acknowledgements: This work was funded by the EU-FP7 InGOS project. We thank Ebba Dellwik (Technical University of Denmark) for providing sonic anemometer data. References: Kormann, R. and Meixner, F.X., 2001. An Analytical Footprint Model For Non-Neutral Stratification. Boundary-Layer Meteorology, 99(2): 207-224. Neftel, A., Spirig, C. and Ammann, C., 2008. Application and test of a simple tool for operational footprint evaluations. Environmental Pollution, 152(3): 644-652.
DETAIL VIEW OF UPPER TRAM TERMINAL STRUCTURE, LOOKING SOUTH TOWARD ...
DETAIL VIEW OF UPPER TRAM TERMINAL STRUCTURE, LOOKING SOUTH TOWARD THE FRONT OF THE STRUCTURE. THE WHEELS AT THE TOP OF THE TRAM BUCKETS RODE OFF THE STATIONARY CABLES ONTO THE TRACK SUPPORTED BY THE "C" IRONS SUSPENDED FROM THE TOP TIMBERS ON THE LEFT AND RIGHT. THE BUCKET OPENING MECHANISM IS ON THE LEFT, AND PART OF THE CLOSING MECHANISM ON THE RIGHT EDGE OF THE FRAME. THE TWO CABLES AT CENTER ARE THE STATIONARY TRAM CABLES THAT RUN ALONG THE TOP OF THE SUPPORT TOWERS ON WHICH THE WHEELS OF THE TRAM BUCKETS RODE. THEY ARE ANCHORED AT GROUND LEVEL JUST OFF FRAME TO THE LOWER LEFT. - Keane Wonder Mine, Park Route 4 (Daylight Pass Cutoff), Death Valley Junction, Inyo County, CA
2004-08-05
KENNEDY SPACE CENTER, FLA. - Brig. Gen. J. Gregory Pavlovich, 45th Space Wing, addresses guests at the ribbon cutting for the Enhanced Firing Range on Schwartz Rd. at Kennedy Space Center. NASA’s Federal Law Enforcement Training Academy’s firing range has been upgraded to include a “rifle-grade” shoot house, a portable, tactical “shoot-back” trailer for cover and concealment drills, automated running targets and a new classroom facility. They are added to the existing three firearms ranges, “pistol-grade” shoot house, obstacle course and rappel tower. NASA’s Security Management and Safeguards Office funded the enhancements in order to improve ability to train the KSC security force and to support local, state and federal law enforcement agencies in Homeland Security.
2004-08-05
KENNEDY SPACE CENTER, FLA. - At the ribbon cutting for the Enhanced Firing Range on Schwartz Rd. at Kennedy Space Center, Center Director Jim Kennedy practices firing on the new range. NASA’s Federal Law Enforcement Training Academy’s firing range has been upgraded to include a “rifle-grade” shoot house, a portable, tactical “shoot-back” trailer for cover and concealment drills, automated running targets and a new classroom facility. They are added to the existing three firearms ranges, “pistol-grade” shoot house, obstacle course and rappel tower. NASA’s Security Management and Safeguards Office funded the enhancements in order to improve ability to train the KSC security force and to support local, state and federal law enforcement agencies in Homeland Security.
[Emergency medicine after a catastrophic disaster: from a view of geriatrics and gerontology].
Okinaga, Shoji; Daito, Hisayoshi; Suzuki, Motoi; Shiihara, Jun; Arai, Hiroyuki
2013-06-01
The megathrust earthquake and the towering tsunami hit the east coast of Japan on March 11th of 2011 after intervals of 1,142 years. About 90 % of nearly 20,000 victims were drowned in devastating waves, while every town and city along the coast turned out to be a ruin. Over 400,000 people were forced to move to the evacuation centers where the evacuees slept on the floor without electricity, running water or heating systems at freezing nights. Emergency medicine, therefore, was more required during the evacuation phase than during the acute phase of the tsunami disaster. Here discussed is the phenomenon that the events happened mostly to the elderly evacuees especially in the swept area by silty polluted seawater.
NASA Astrophysics Data System (ADS)
Musi, Richard; Grange, Benjamin; Diago, Miguel; Topel, Monika; Armstrong, Peter; Slocum, Alexander; Calvet, Nicolas
2017-06-01
A molten salt direct absorption receiver, CSPonD, used to simultaneously collect and store thermal energy is being tested by Masdar Institute and MIT in Abu Dhabi, UAE. Whilst a research-scale prototype has been combined with a beam-down tower in Abu Dhabi, the original design coupled the receiver with a hillside heliostat field. With respect to a conventional power-tower setup, a hillside solar field presents the advantages of eliminating tower costs, heat tracing equipment, and high-pressure pumps. This analysis considers the industrial viability of the CSPonD concept by modeling a 10 MWe up-scaled version of a molten salt direct absorption receiver combined with a hillside heliostat field. Five different slope angles are initially simulated to determine the optimum choice using a combination of lowest LCOE and highest IRR, and sensitivity analyses are carried out based on thermal energy storage duration, power output, and feed-in tariff price. Finally, multi-objective optimization is undertaken to determine a Pareto front representing optimum cases. The study indicates that a 40° slope and a combination of 14 h thermal energy storage with a 40-50 MWe power output provide the best techno-economic results. By selecting one simulated result and using a feed-in tariff of 0.25 /kWh, a competitive IRR of 15.01 % can be achieved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wagner, Volker; Paa, Wolfgang; Triebel, Wolfgang
We describe a specially designed diode pumped solid state laser system based on the disk laser architecture for combustion diagnostics under microgravity (μg) conditions at the drop tower in Bremen. The two-stage oscillator-amplifier-system provides an excellent beam profile (TEM{sub 00}) at narrowband operation (Δλ < 1 pm) and is tunable from 1018 nm to 1052 nm. The laser repetition rate of up to 4 kHz at pulse durations of 10 ns enables the tracking of processes on a millisecond time scale. Depending on the specific issue it is possible to convert the output radiation up to the fourth harmonic aroundmore » 257 nm. The very compact laser system is integrated in a slightly modified drop capsule and withstands decelerations of up to 50 g (>11 ms). At first the concept of the two-stage disk laser is briefly explained, followed by a detailed description of the disk laser adaption to the drop tower requirements with special focus on the intended use under μg conditions. In order to demonstrate the capabilities of the capsule laser as a tool for μg combustion diagnostics, we finally present an investigation of the precursor-reactions before the droplet ignition using 2D imaging of the Laser Induced Fluorescence of formaldehyde.« less
2. Southern Light Tower and Northern Light Tower, view north, ...
2. Southern Light Tower and Northern Light Tower, view north, south sides - Kennebec River Light Station, South side of Doubling Point Road, off State Highway 127, 1.8 miles south of U.S. Route 1, Arrowsic, Sagadahoc County, ME
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jonkman, Jason; Damiani, Rick R; Struve, Achim
The call for more cost-effective and environmentally friendly tower concepts is motivated by tower costs [1] and tower CO2-emission contributions [2], which are high relative to the whole wind turbine system. The proposed rotatable tower concept with yaw bearing at the bottom instead of the top of the tower will provide beneficial economic and environmental impacts to the turbine system. This wind alignment capability indicates a load-direction-derived tower design. By combining this approach with a lattice concept, large material and cost savings for the tower can be achieved. This paper presents a way to analyze and verify the proposed designmore » through aero-servo-elastic simulations, which make future certifications of rotatable tower concepts viable. For this reason, the state-of-the-art, open-source lattice-tower finite-element-method (FEM) module SubDyn [10], developed by the National Renewable Energy Laboratory, has been modified to account for arbitrary member cross-sections. Required changes in the beam element stiffness and mass matrix formulation took place according to an energy method [13]. All validated adaptions will be usable within the aero-servo-elastic simulation framework FAST and are also beneficial for other nonrotatable lattice structures.« less
Gu, Yingxin; Howard, Daniel M.; Wylie, Bruce K.; Zhang, Li
2012-01-01
Flux tower networks (e. g., AmeriFlux, Agriflux) provide continuous observations of ecosystem exchanges of carbon (e. g., net ecosystem exchange), water vapor (e. g., evapotranspiration), and energy between terrestrial ecosystems and the atmosphere. The long-term time series of flux tower data are essential for studying and understanding terrestrial carbon cycles, ecosystem services, and climate changes. Currently, there are 13 flux towers located within the Great Plains (GP). The towers are sparsely distributed and do not adequately represent the varieties of vegetation cover types, climate conditions, and geophysical and biophysical conditions in the GP. This study assessed how well the available flux towers represent the environmental conditions or "ecological envelopes" across the GP and identified optimal locations for future flux towers in the GP. Regression-based remote sensing and weather-driven net ecosystem production (NEP) models derived from different extrapolation ranges (10 and 50%) were used to identify areas where ecological conditions were poorly represented by the flux tower sites and years previously used for mapping grassland fluxes. The optimal lands suitable for future flux towers within the GP were mapped. Results from this study provide information to optimize the usefulness of future flux towers in the GP and serve as a proxy for the uncertainty of the NEP map.
NASA Astrophysics Data System (ADS)
Guo, Minghuan; Sun, Feihu; Wang, Zhifeng
2017-06-01
The solar tower concentrator is mainly composed of the central receiver on the tower top and the heliostat field around the tower. The optical efficiencies of a solar tower concentrator are important to the whole thermal performance of the solar tower collector, and the aperture plane of a cavity receiver or the (inner or external) absorbing surface of any central receiver is a key interface of energy flux. So it is necessary to simulate and analyze the concentrated time-changing solar flux density distributions on the flat or curved receiving surface of the collector, with main optical errors considered. The transient concentrated solar flux on the receiving surface is the superimposition of the flux density distributions of all the normal working heliostats in the field. In this paper, we will mainly introduce a new backward ray tracing (BRT) method combined with the lumped effective solar cone, to simulate the flux density map on the receiving-surface. For BRT, bundles of rays are launched at the receiving-surface points of interest, strike directly on the valid cell centers among the uniformly sampled mirror cell centers in the mirror surface of the heliostats, and then direct to the effective solar cone around the incident sun beam direction after reflection. All the optical errors are convoluted into the effective solar cone. The brightness distribution of the effective solar cone is here supposed to be circular Gaussian type. The mirror curvature can be adequately formulated by certain number of local normal vectors at the mirror cell centers of a heliostat. The shading & blocking mirror region of a heliostat by neighbor heliostats and also the solar tower shading on the heliostat mirror are all computed on the flat-ground-plane platform, i.e., projecting the mirror contours and the envelope cylinder of the tower onto the horizontal ground plane along the sun-beam incident direction or along the reflection directions. If the shading projection of a sampled mirror point of the current heliostat is inside the shade cast of a neighbor heliostat or in the shade cast of the tower, this mirror point should be shaded from the incident sun beam. A code based on this new ray tracing method for the 1MW Badaling solar tower power plant in Beijing has been developed using MATLAB. There are 100 azimuth-elevation tracking heliostats in the solar field and the total tower is 118 meters high. The mirror surface of the heliostats is 10m wide and 10m long, it is composed of 8 rows × 8 columns of square mirror facets and each mirror facet has the size of 1.25m×1.25m. This code also was verified by two sets of sun-beam concentrating experiments of the heliostat field on the June 14, 2015. One set of optical experiments were conducted between some typical heliostats to verify the shading & blocking computation of the code, since shading & blocking computation is the most complicated, time-consuming and important optical computing section of the code. The other set of solar concentrating tests were carried out on the field center heliostat (No. 78) to verify the simulated the solar flux images on the white target region of the northern wall of the tower. The target center is 74.5 m high to the ground plane.
Environmental Assessment for Buckley Air Force Base Air Traffic Control Tower and Fire Station
2003-05-01
Guard Base, Arapahoe County, Colorado, Colorado National Heritage Program, Colorado State University , Ft. Collins, CO, July 2000. COANG, 2000d. Final... Westcliffe Publishers, Inc, Englewood, CO, 1995. Hoogland, 1995. Hoogland, John L. The Black-Tailed Prairie Dog- Social Life of a Burrowing Mammal. The... University of Chicago Press. Chicago, IL, 1995. Hranac, 2002. Email: Utilities Information, from Civ 460/CES/CEV to Civ 460/CES/CEVP dated 16
Assessment of Proposed Cab Glass Coating for FAA Control Towers
2015-11-16
report would be prepared after the initial coating and evaluation (with sprayed water) and then a final report after the 6 month study period to assess...Distribution A: Approved for public release. AFRL-RH-WP-TR-2015-0074 Assessment of Proposed Cab Glass Coating for FAA Control...REPORT TYPE Interim 3. DATES COVERED (From - To) 30 Jun 2014 – 1 Nov 2015 4. TITLE AND SUBTITLE Assessment of Proposed Cab Glass Coating
Spiteri, Thierry; Ogawa, Sonoko; Musatov, Sergei; Pfaff, Donald W; Agmo, Anders
2012-04-21
Ovariectomized females were given an infusion in the medial preoptic area (MPOA) of a viral vector carrying either a shRNA directed against the estrogen receptor α (ERα) or luciferase. The females were subjected to a test for sexual incentive motivation immediately followed by a test for receptivity and proceptive behaviors. Two weeks later they were tested in the light/dark choice procedure, and after another 2 weeks they were subjected to a test in a brightly lit open field. Finally, the females were given free access to a running wheel for 88h. The females were treated with estradiol benzoate (EB), 18 or 1.5μg/kg, in randomized order 52h before each test except the running wheel. In that experiment, they were given EB 48h after introduction into the wheel cage. They were given progesterone, 1mg/rat, about 4h before all tests, except the running wheel. The shRNA reduced the number of ERα with 83%. Females with few ERα in the MPOA showed increased lordosis quotient after the 1.5μg/kg dose of EB. There was no effect on proceptive behaviors or on rejections. When given the 18μg/kg EB dose, there was no difference between females with few preoptic ERα and controls. In the test for sexual incentive motivation, females with few preoptic ERα approached the castrated male incentive more than controls, regardless of EB dose. They also moved a shorter distance. In the light/dark choice test as well as in the open field, females with few ERα in the MPOA showed signs of reduced fear/anxiety, since they spent more time in the light part of the dark/light box and in the center of the open field. Finally, the data from the running wheel showed that females with few preoptic ERα failed to show enhanced activity after treatment with EB. These data show that the preoptic ERα inhibits lordosis in females with an intermediate level of receptivity while it fails to do so in fully receptive females. The ERα in the MPOA seems to be necessary for selective approach to a sexual incentive. Finally, activation of this receptor appears to have anxiogenic effects in the procedures employed here. A hypothesis for how all these actions of the preoptic ERα contributes to efficient reproductive behavior is outlined. Copyright © 2012 Elsevier B.V. All rights reserved.
Role of bacterial adhesion in the microbial ecology of biofilms in cooling tower systems.
Liu, Yang; Zhang, Wei; Sileika, Tadas; Warta, Richard; Cianciotto, Nicholas P; Packman, Aaron
2009-01-01
The fate of the three heterotrophic biofilm forming bacteria, Pseudomonas aeruginosa, Klebsiella pneumoniae and Flavobacterium sp. in pilot scale cooling towers was evaluated both by observing the persistence of each species in the recirculating water and the formation of biofilms on steel coupons placed in each cooling tower water reservoir. Two different cooling tower experiments were performed: a short-term study (6 days) to observe the initial bacterial colonization of the cooling tower, and a long-term study (3 months) to observe the ecological dynamics with repeated introduction of the test strains. An additional set of batch experiments (6 days) was carried out to evaluate the adhesion of each strain to steel surfaces under similar conditions to those found in the cooling tower experiments. Substantial differences were observed in the microbial communities that developed in the batch systems and cooling towers. P. aeruginosa showed a low degree of adherence to steel surfaces both in batch and in the cooling towers, but grew much faster than K. pneumoniae and Flavobacterium in mixed-species biofilms and ultimately became the dominant organism in the closed batch systems. However, the low degree of adherence caused P. aeruginosa to be rapidly washed out of the open cooling tower systems, and Flavobacterium became the dominant microorganism in the cooling towers in both the short-term and long-term experiments. These results indicate that adhesion, retention and growth on solid surfaces play important roles in the bacterial community that develops in cooling tower systems.
Role of bacterial adhesion in the microbial ecology of biofilms in cooling tower systems
Liu, Yang; Zhang, Wei; Sileika, Tadas; Warta, Richard; Cianciotto, Nicholas P.; Packman, Aaron
2009-01-01
The fate of the three heterotrophic biofilm forming bacteria, Pseudomonas aeruginosa, Klebsiella pneumoniae and Flavobacterium sp. in pilot scale cooling towers was evaluated both by observing the persistence of each species in the recirculating water and the formation of biofilms on steel coupons placed in each cooling tower water reservoir. Two different cooling tower experiments were performed: a short-term study (6 days) to observe the initial bacterial colonization of the cooling tower, and a long-term study (3 months) to observe the ecological dynamics with repeated introduction of the test strains. An additional set of batch experiments (6 days) was carried out to evaluate the adhesion of each strain to steel surfaces under similar conditions to those found in the cooling tower experiments. Substantial differences were observed in the microbial communities that developed in the batch systems and cooling towers. P. aeruginosa showed a low degree of adherence to steel surfaces both in batch and in the cooling towers, but grew much faster than K. pneumoniae and Flavobacterium in mixed-species biofilms and ultimately became the dominant organism in the closed batch systems. However, the low degree of adherence caused P. aeruginosa to be rapidly washed out of the open cooling tower systems, and Flavobacterium became the dominant microorganism in the cooling towers in both the short-term and long-term experiments. These results indicate that adhesion, retention and growth on solid surfaces play important roles in the bacterial community that develops in cooling tower systems. PMID:19177226
76 FR 3524 - Final Flood Elevation Determinations
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-20
... proof Flood Insurance Study and FIRM available at the address cited below for each community. The BFEs...-Long Run Road. Duck Run (backwater effects from Scioto Approximately 547 feet +535 Unincorporated Areas of River). upstream of Duck Run- Scioto County. Otway Road. Just downstream of +535 McDermott Pond...
DOT National Transportation Integrated Search
2004-12-01
The issue of red light running (RLR) has long been a problem throughout the United States. : There is considerable debate within the general public and public agencies regarding the use of : photographic enforcement to deter red light violations. Man...
8. VIEW OF THE EAST BASE CONNECTION OF ANTENNA TOWER ...
8. VIEW OF THE EAST BASE CONNECTION OF ANTENNA TOWER S-111 FACING NORTHEAST. BUILDING 1 AND ANTENNA TOWER S-110 IN THE BACKGROUND. - U.S. Naval Base, Pearl Harbor, Lualualei Radio Transmitter, Edison & Tower Drives, Pearl City, Honolulu County, HI
8. GENERAL VIEW OF TOWER 32, LEFT, AND TOWER 31, ...
8. GENERAL VIEW OF TOWER 32, LEFT, AND TOWER 31, RIGHT. VIEW LOOKING NORTH SHOWING AERIAL WIRE DESIGN WITH VERTICAL 'TOP HAT' WIRES IN CENTER. - Chollas Heights Naval Radio Transmitting Facility, 6410 Zero Road, San Diego, San Diego County, CA
Group Planning and Task Efficiency with Complex Problems. Final Report.
ERIC Educational Resources Information Center
Lawson, E. D.
One hundred eighty 4-man groups (90 of men and 90 of women) using 3 types of net (All-Channel, Wheel and Circle) under 3 conditions (Planning Period (PP), Rest Period (RP) and Control) were run in a single session with 5 complex problems to determine whether a single 2-minute planning period after solution of the first problem would result in…
1999-10-14
KENNEDY SPACE CENTER, FLA. — Two 34-year-old towers on Launch Complex 41, Cape Canaveral Air Station, fall to the ground amid the black smoke from explosives set to topple them. Weighing two million pounds, the umbilical tower (left) was approximately 200 feet high. The taller 300-foot Mobile Service Tower (right) weighs five million pounds. About 200 pounds of linear-shaped charges were used to topple the towers so that the materials can be recycled. Adjacent to the towers are lightning protection structures, which will remain on the site. The towers are being demolished to make room for Lockheed Martin's 14-acre Vehicle Integration Facility (VIF), under construction. The implosion and removal of the tower debris is expected to be completed in two months. The VIF will be used for Lockheed Martin's Atlas V Launch System.
1999-10-14
KENNEDY SPACE CENTER, FLA. — Two 34-year-old towers on Launch Complex 41, Cape Canaveral Air Station, lie on the ground amid the black smoke from explosives set to topple them. Weighing two million pounds, the umbilical tower (left) was approximately 200 feet high. The taller 300-foot Mobile Service Tower (right) weighs five million pounds. About 200 pounds of linear-shaped charges were used to topple the towers so that the materials can be recycled. Adjacent to the towers are lightning protection structures, which will remain on the site. The towers are being demolished to make room for Lockheed Martin's 14-acre Vehicle Integration Facility (VIF), under construction. The implosion and removal of the tower debris is expected to be completed in two months. The VIF will be used for Lockheed Martin's Atlas V Launch System.
NASA Astrophysics Data System (ADS)
Miura, T.; Kato, A.; Wang, J.; Vargas, M.; Lindquist, M.
2015-12-01
Satellite vegetation index (VI) time series data serve as an important means to monitor and characterize seasonal changes of terrestrial vegetation and their interannual variability. It is, therefore, critical to ensure quality of such VI products and one method of validating VI product quality is cross-comparison with in situ flux tower measurements. In this study, we evaluated the quality of VI time series derived from Visible Infrared Imaging Radiometer Suite (VIIRS) onboard the Suomi National Polar-orbiting Partnership (NPP) spacecraft by cross-comparison with in situ radiation flux measurements at select flux tower sites over North America and Europe. VIIRS is a new polar-orbiting satellite sensor series, slated to replace National Oceanic and Atmospheric Administration's Advanced Very High Resolution Radiometer in the afternoon overpass and to continue the highly-calibrated data streams initiated with Moderate Resolution Imaging Spectrometer of National Aeronautics and Space Administration's Earth Observing System. The selected sites covered a wide range of biomes, including croplands, grasslands, evergreen needle forest, woody savanna, and open shrublands. The two VIIRS indices of the Top-of-Atmosphere (TOA) Normalized Difference Vegetation Index (NDVI) and the atmospherically-corrected, Top-of-Canopy (TOC) Enhanced Vegetation Index (EVI) (daily, 375 m spatial resolution) were compared against the TOC NDVI and a two-band version of EVI (EVI2) calculated from tower radiation flux measurements, respectively. VIIRS and Tower VI time series showed comparable seasonal profiles across biomes with statistically significant correlations (> 0.60; p-value < 0.01). "Start-of-season (SOS)" phenological metric values extracted from VIIRS and Tower VI time series were also highly compatible (R2 > 0.95), with mean differences of 2.3 days and 5.0 days for the NDVI and the EVI, respectively. These results indicate that VIIRS VI time series can capture seasonal evolution of vegetated land surface as good as in situ radiometric measurements. Future studies that address biophysical or physiological interpretations of Tower VI time series derived from radiation flux measurements are desirable.
Dynamics of carbon, water and energy cycles in a heterogeneous landscape and a changing climate
NASA Astrophysics Data System (ADS)
Schmidt, A.; Law, B. E.; Still, C. J.; Hilker, T.
2016-12-01
The combined effects of changes in land-use and land cover (LULC) and climate on carbon and water cycling need to be assessed at regional scales. LULC changes over time have many drivers such as expanding urban areas, exploration of new agricultural areas due to overused natural resources of current agricultural areas (e.g. degraded soil), economical reasons, or policy changes that encourage the use of alternative energy resources. Our study assesses the effects of conversion of semi-arid sagebrush and agricultural crops to bioenergy production on carbon, water and energy cycling, and resulting heating or cooling effects. Our project focusses on Oregon, where agricultural crops, significant forest area, and urban expansion are coupled with a strong spatial climate gradient that allows us to examine influences on carbon sequestration by the terrestrial biosphere. Our inverse modeling results showed that the prior fluxes modelled with CLM4.5 underestimated NEE in the highly productive western Douglas fir forests by more than 50%. Based on the results of our Bayesian inversion, we optimized ecosystem fluxes and changed CLM model parameters accordingly. By integrating remote sensing LULC data, eddy covariance data from flux sites, tall tower CO2 observations, biomass estimates from field samples, and CLM4.5, we predict current and future statewide carbon sequestration with unprecedented accuracy. Using inventories and tower flux data, we determined the effect of conversion of hay and grass seed cropland (323,200 ha) to hybrid poplar and found the state NEP increased from 4 TgCO2 per year to 13 TgCO2 per year for that area. The last coal power plant in the state (Boardman) is in the process of switching from coal combustion to biofuel burning to meet the state's goal for the reduction of greenhouse gas emissions. Our results show that the 7816 tons of biomass per day to keep the 518 MW power plant running at base load would amount to 35,000 hectares of hybrid poplar per year under current climate conditions. The improved CLM4.5 model will be used to evaluate the impacts of this land use change on the net ecosystem carbon balance under future climate conditions.
Neural network-based run-to-run controller using exposure and resist thickness adjustment
NASA Astrophysics Data System (ADS)
Geary, Shane; Barry, Ronan
2003-06-01
This paper describes the development of a run-to-run control algorithm using a feedforward neural network, trained using the backpropagation training method. The algorithm is used to predict the critical dimension of the next lot using previous lot information. It is compared to a common prediction algorithm - the exponentially weighted moving average (EWMA) and is shown to give superior prediction performance in simulations. The manufacturing implementation of the final neural network showed significantly improved process capability when compared to the case where no run-to-run control was utilised.
PBF Cooling Tower and it Auxiliary Building (PER624) to left ...
PBF Cooling Tower and it Auxiliary Building (PER-624) to left of tower. Camera facing west and the east louvered face of the tower. Details include secondary coolant water riser piping and flow control valves (butterfly valves) to distribute water evenly to all sections of tower. Photographer: Holmes. Date: May, 20, 1970. INEEL negative no. 70-2322 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
The performance of the CASTOR calorimeter during LHC Run 2
NASA Astrophysics Data System (ADS)
van de Klundert, Merijn H. F.; CMS Collaboration
2017-11-01
CASTOR is an electromagnetic and hadronic tungsten-quartz sampling Cerenkov calorimeter located at the Compact Muon Solenoid experiment at the Large Hadron Collider. The detector has pseudorapidity borders at -5.2 and -6.6. An overview is presented on the various aspects of CASTOR’s performance and their relations during LHC Run 2. The equalisation of CASTOR’s channels is performed using beam-halo muons. Thereafter, CASTOR’s pedestal spectrum is studied. It is shown that noise estimates which are extracted using a fit, give on average a 10% lower threshold than statistical estimates. Gain correction factors, which are needed for the intercalibration, are obtained using a statistical, in-situ applicable method. The results of this method are shown to be reasonably consistent with laboratory measurements. Penultimately the absolute calibration is discussed, with emphasis on the relation between the scale uncertainty and CASTOR’s alignment. It is shown that the alignment’s contribution to the systematic uncertainty is decreased by over 50% in LHC Run 2 w.r.t. LHC Run 1. Finally generalisations of the conclusions to other subsystems and future improvements are discussed.
2. VIEW SOUTHWEST, prime search radar tower, height finder radar ...
2. VIEW SOUTHWEST, prime search radar tower, height finder radar towards, height finder radar towers, and radar tower (unknown function) - Fort Custer Military Reservation, P-67 Radar Station, .25 mile north of Dickman Road, east of Clark Road, Battle Creek, Calhoun County, MI
4. VIEW NORTHEAST, radar tower (unknown function), prime search radar ...
4. VIEW NORTHEAST, radar tower (unknown function), prime search radar tower, emergency power building, and height finder radar tower - Fort Custer Military Reservation, P-67 Radar Station, .25 mile north of Dickman Road, east of Clark Road, Battle Creek, Calhoun County, MI
3. View from former light tower to Cape Elizabeth Light ...
3. View from former light tower to Cape Elizabeth Light Tower, view northeast, southwest side of Cape Elizabeth Tower - Cape Elizabeth Light Station, Near Two Lights State Park at end of Two Lights Road, off State Highway 77, Cape Elizabeth, Cumberland County, ME
Robertson, Amy N.; Wendt, Fabian; Jonkman, Jason M.; ...
2017-10-01
This paper summarizes the findings from Phase II of the Offshore Code Comparison, Collaboration, Continued, with Correlation project. The project is run under the International Energy Agency Wind Research Task 30, and is focused on validating the tools used for modeling offshore wind systems through the comparison of simulated responses of select system designs to physical test data. Validation activities such as these lead to improvement of offshore wind modeling tools, which will enable the development of more innovative and cost-effective offshore wind designs. For Phase II of the project, numerical models of the DeepCwind floating semisubmersible wind system weremore » validated using measurement data from a 1/50th-scale validation campaign performed at the Maritime Research Institute Netherlands offshore wave basin. Validation of the models was performed by comparing the calculated ultimate and fatigue loads for eight different wave-only and combined wind/wave test cases against the measured data, after calibration was performed using free-decay, wind-only, and wave-only tests. The results show a decent estimation of both the ultimate and fatigue loads for the simulated results, but with a fairly consistent underestimation in the tower and upwind mooring line loads that can be attributed to an underestimation of wave-excitation forces outside the linear wave-excitation region, and the presence of broadband frequency excitation in the experimental measurements from wind. Participant results showed varied agreement with the experimental measurements based on the modeling approach used. Modeling attributes that enabled better agreement included: the use of a dynamic mooring model; wave stretching, or some other hydrodynamic modeling approach that excites frequencies outside the linear wave region; nonlinear wave kinematics models; and unsteady aerodynamics models. Also, it was observed that a Morison-only hydrodynamic modeling approach could create excessive pitch excitation and resulting tower loads in some frequency bands.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robertson, Amy N.; Wendt, Fabian; Jonkman, Jason M.
This paper summarizes the findings from Phase II of the Offshore Code Comparison, Collaboration, Continued, with Correlation project. The project is run under the International Energy Agency Wind Research Task 30, and is focused on validating the tools used for modeling offshore wind systems through the comparison of simulated responses of select system designs to physical test data. Validation activities such as these lead to improvement of offshore wind modeling tools, which will enable the development of more innovative and cost-effective offshore wind designs. For Phase II of the project, numerical models of the DeepCwind floating semisubmersible wind system weremore » validated using measurement data from a 1/50th-scale validation campaign performed at the Maritime Research Institute Netherlands offshore wave basin. Validation of the models was performed by comparing the calculated ultimate and fatigue loads for eight different wave-only and combined wind/wave test cases against the measured data, after calibration was performed using free-decay, wind-only, and wave-only tests. The results show a decent estimation of both the ultimate and fatigue loads for the simulated results, but with a fairly consistent underestimation in the tower and upwind mooring line loads that can be attributed to an underestimation of wave-excitation forces outside the linear wave-excitation region, and the presence of broadband frequency excitation in the experimental measurements from wind. Participant results showed varied agreement with the experimental measurements based on the modeling approach used. Modeling attributes that enabled better agreement included: the use of a dynamic mooring model; wave stretching, or some other hydrodynamic modeling approach that excites frequencies outside the linear wave region; nonlinear wave kinematics models; and unsteady aerodynamics models. Also, it was observed that a Morison-only hydrodynamic modeling approach could create excessive pitch excitation and resulting tower loads in some frequency bands.« less
The optimal operation of cooling tower systems with variable-frequency control
NASA Astrophysics Data System (ADS)
Cao, Yong; Huang, Liqing; Cui, Zhiguo; Liu, Jing
2018-02-01
This study investigates the energy performance of chiller and cooling tower systems integrated with variable-frequency control for cooling tower fans and condenser water pumps. With regard to an example chiller system serving an office building, Chiller and cooling towers models were developed to assess how different variable-frequency control methods of cooling towers fans and condenser water pumps influence the trade-off between the chiller power, pump power and fan power under various operating conditions. The matching relationship between the cooling tower fans frequency and condenser water pumps frequency at optimal energy consumption of the system is introduced to achieve optimum system performance.
Main photoautotrophic components of biofilms in natural draft cooling towers.
Hauer, Tomáš; Čapek, Petr; Böhmová, Petra
2016-05-01
While photoautotrophic organisms are an important component of biofilms that live in certain regions of natural draft cooling towers, little is known about these communities. We therefore examined 18 towers at nine sites to identify the general patterns of community assembly in three distinct tower parts, and we examined how community structures differ depending on geography. We also compared the newly acquired data with previously published data. The bottom sections of draft cooling towers are mainly settled by large filamentous algae, primarily Cladophora glomerata. The central portions of towers host a small amount of planktic algae biomass originating in the cooling water. The upper fourths of towers are colonized by biofilms primarily dominated by cyanobacteria, e.g., members of the genera Gloeocapsa and Scytonema. A total of 41 taxa of phototrophic microorganisms were identified. Species composition of the upper fourth of all towers was significantly affected by cardinal position. There was different species composition at positions facing north compared to positions facing south. West- and east-facing positions were transitory and highly similar to each other in terms of species composition. Biofilms contribute to the degradation of paint coatings inside towers.
Concentrating Solar Power Projects - ACME Solar Tower | Concentrating Solar
: 2.5 MW Gross: 2.5 MW Status: Operational Start Year: 2011 Do you have more information, corrections Contact(s): SolarPACES Start Production: April 2011 Participants Developer(s): ACME Group ; eSolar Owner(s
An Estimate of Avian Mortality at Communication Towers in the United States and Canada
Longcore, Travis; Rich, Catherine; Mineau, Pierre; MacDonald, Beau; Bert, Daniel G.; Sullivan, Lauren M.; Mutrie, Erin; Gauthreaux, Sidney A.; Avery, Michael L.; Crawford, Robert L.; Manville, Albert M.; Travis, Emilie R.; Drake, David
2012-01-01
Avian mortality at communication towers in the continental United States and Canada is an issue of pressing conservation concern. Previous estimates of this mortality have been based on limited data and have not included Canada. We compiled a database of communication towers in the continental United States and Canada and estimated avian mortality by tower with a regression relating avian mortality to tower height. This equation was derived from 38 tower studies for which mortality data were available and corrected for sampling effort, search efficiency, and scavenging where appropriate. Although most studies document mortality at guyed towers with steady-burning lights, we accounted for lower mortality at towers without guy wires or steady-burning lights by adjusting estimates based on published studies. The resulting estimate of mortality at towers is 6.8 million birds per year in the United States and Canada. Bootstrapped subsampling indicated that the regression was robust to the choice of studies included and a comparison of multiple regression models showed that incorporating sampling, scavenging, and search efficiency adjustments improved model fit. Estimating total avian mortality is only a first step in developing an assessment of the biological significance of mortality at communication towers for individual species or groups of species. Nevertheless, our estimate can be used to evaluate this source of mortality, develop subsequent per-species mortality estimates, and motivate policy action. PMID:22558082
An estimate of avian mortality at communication towers in the United States and Canada.
Longcore, Travis; Rich, Catherine; Mineau, Pierre; MacDonald, Beau; Bert, Daniel G; Sullivan, Lauren M; Mutrie, Erin; Gauthreaux, Sidney A; Avery, Michael L; Crawford, Robert L; Manville, Albert M; Travis, Emilie R; Drake, David
2012-01-01
Avian mortality at communication towers in the continental United States and Canada is an issue of pressing conservation concern. Previous estimates of this mortality have been based on limited data and have not included Canada. We compiled a database of communication towers in the continental United States and Canada and estimated avian mortality by tower with a regression relating avian mortality to tower height. This equation was derived from 38 tower studies for which mortality data were available and corrected for sampling effort, search efficiency, and scavenging where appropriate. Although most studies document mortality at guyed towers with steady-burning lights, we accounted for lower mortality at towers without guy wires or steady-burning lights by adjusting estimates based on published studies. The resulting estimate of mortality at towers is 6.8 million birds per year in the United States and Canada. Bootstrapped subsampling indicated that the regression was robust to the choice of studies included and a comparison of multiple regression models showed that incorporating sampling, scavenging, and search efficiency adjustments improved model fit. Estimating total avian mortality is only a first step in developing an assessment of the biological significance of mortality at communication towers for individual species or groups of species. Nevertheless, our estimate can be used to evaluate this source of mortality, develop subsequent per-species mortality estimates, and motivate policy action.
Spiker, Andrea M; Dixit, Sameer; Cosgarea, Andrew J
2012-12-01
The running portion of the triathlon represents the final leg of the competition and, by some reports, the most important part in determining a triathlete's overall success. Although most triathletes spend most of their training time on cycling, running injuries are the most common injuries encountered. Common causes of running injuries include overuse, lack of rest, and activities that aggravate biomechanical predisposers of specific injuries. We discuss the running-associated injuries in the hip, knee, lower leg, ankle, and foot of the triathlete, and the causes, presentation, evaluation, and treatment of each.
Analysis of Ideal Towers for Tall Wind Applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dykes, Katherine L; Damiani, Rick R; Roberts, Joseph O
Innovation in wind turbine tower design is of significant interest for future development of wind power plants. First, wind turbine towers account for a large portion of overall capital expenditures for wind power projects. Second, for low wind-resource regions of the world, the use of low-cost tall-tower technology has the potential to open new markets for development. This study investigates the relative potential of various tower configurations in terms of mass and cost. For different market applications and hub heights, idealized tall towers are designed and compared. The results show that innovation in wind turbine controls makes reaching higher hubmore » heights with current technology economically viable. At the same time, new technologies hold promise for reducing tower costs as these technologies mature and hub heights reach twice the current average.« less
Analysis of Ideal Towers for Tall Wind Applications: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dykes, Katherine L; Damiani, Rick R; Roberts, Joseph O
Innovation in wind turbine tower design is of significant interest for future development of wind power plants. First, wind turbine towers account for a large portion of overall capital expenditures for wind power projects. Second, for low wind-resource regions of the world, the use of low-cost tall-tower technology has the potential to open new markets for development. This study investigates the relative potential of various tower configurations in terms of mass and cost. For different market applications and hub heights, idealized tall towers are designed and compared. The results show that innovation in wind turbine controls makes reaching higher hubmore » heights with current technology economically viable. At the same time, new technologies hold promise for reducing tower costs as these technologies mature and hub heights reach twice the current average.« less
1999-10-14
KENNEDY SPACE CENTER, FLA. — Two 34-year-old towers on Launch Complex 41, Cape Canaveral Air Station, fall to the ground amid the black smoke from explosives set to topple them. Weighing two million pounds, the umbilical tower (left) was approximately 200 feet high. The taller 300-foot Mobile Service Tower (right), still falling, weighs five million pounds. About 200 pounds of linear-shaped charges were used to topple the towers so that the materials can be recycled. Adjacent to the towers are lightning protection structures, which will remain on the site. The towers are being demolished to make room for Lockheed Martin's 14-acre Vehicle Integration Facility (VIF), under construction. The implosion and removal of the tower debris is expected to be completed in two months. The VIF will be used for Lockheed Martin's Atlas V Launch System.
NASA Astrophysics Data System (ADS)
Xiao, Zhongxiu
2018-04-01
A Method of Measuring and Correcting Tilt of Anti - vibration Wind Turbines Based on Screening Algorithm is proposed in this paper. First of all, we design a device which the core is the acceleration sensor ADXL203, the inclination is measured by installing it on the tower of the wind turbine as well as the engine room. Next using the Kalman filter algorithm to filter effectively by establishing a state space model for signal and noise. Then we use matlab for simulation. Considering the impact of the tower and nacelle vibration on the collected data, the original data and the filtering data are classified and stored by the Screening algorithm, then filter the filtering data to make the output data more accurate. Finally, we eliminate installation errors by using algorithm to achieve the tilt correction. The device based on this method has high precision, low cost and anti-vibration advantages. It has a wide range of application and promotion value.
Use of saline water in energy development. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Israelsen, C.E.; Adams, V.D.; Batty, J.C.
1980-06-01
Information was assembled relative to future energy-related projects in the upper basin, and estimates were made of their anticipated water needs. Using computer models, various options were tested for using saline water for coal-fired power plant cooling. Both cooling towers and brine evaporation ponds were included. Information is presented of several proven water treatment technologies, and comparisons are made of their cost effectiveness when placed in various combinations in the power plant makeup and blowdown water systems. A relative value scale was developed which compares graphically the relative values of waters of different salinities based on three different water treatmentmore » options and predetermined upper limits of cooling tower circulating salinities. Coal from several different mines was slurried in waters of different salinities. Samples were analyzed in the laboratory to determine which constituents had been leached from or absorbed by the coal, and what possible deleterious effects this might have on the burning properties of the coal, or on the water for culinary use or irrigation.« less
Effects of resistance training on running economy and cross-country performance.
Barnes, Kyle R; Hopkins, Will G; McGuigan, Michael R; Northuis, Mark E; Kilding, Andrew E
2013-12-01
Heavy-resistance training and plyometric training offer distinct physiological and neuromuscular adaptations that could enhance running economy and, consequently, distance-running performance. To date, no studies have examined the effect of combining the two modes of training on running economy or performance. Fifty collegiate male and female cross-country runners performed a 5-km time trial and a series of laboratory-based tests to determine aerobic, anthropometric, biomechanical, and neuromuscular characteristics. Thereafter, each athlete participated in a season of six to eight collegiate cross-country races for 13 wk. After the first 4 wk, athletes were randomly assigned to either heavy-resistance or plyometric plus heavy-resistance training. Five days after completing their final competition, runners repeated the same set of laboratory tests. We also estimated the effects of the intervention on competition performance throughout the season using athletes of other teams as controls. Heavy-resistance training produced small-moderate improvements in peak speed, running economy, and neuromuscular characteristics relative to plyometric resistance training, whereas changes in biomechanical measures favored plyometric resistance training. Men made less gains than women in most tests. Both treatments had possibly harmful effects on competition times in men (mean = 0.5%; 90% confidence interval = ±1.2%), but there may have been benefit for some individuals. Both treatments were likely beneficial for all women (-1.2%; ±1.3%), but heavy-resistance training was possibly better than plyometric resistance training. The changes in laboratory-based parameters related to distance-running performance were consistent with the changes in competition times for women but only partly for men. Our data indicate that women should include heavy-resistance training in their programs, but men should be cautious about using it in season until more research establishes whether certain men are positive or negative responders.
Gait-cycle characteristics and running economy in elite Eritrean and European runners.
Santos-Concejero, Jordan; Oliván, Jesús; Maté-Muñoz, José L; Muniesa, Carlos; Montil, Marta; Tucker, Ross; Lucia, Alejandro
2015-04-01
This study aimed to determine whether biomechanical characteristics such as ground-contact time, swing time, and stride length and frequency contribute to the exceptional running economy of East African runners. Seventeen elite long-distance runners (9 Eritrean, 8 European) performed an incremental maximal running test and 3 submaximal running bouts at 17, 19, and 21 km/h. During the tests, gas-exchange parameters were measured to determine maximal oxygen uptake (VO2max) and running economy (RE). In addition, ground-contact time, swing time, stride length, and stride frequency were measured. The European runners had higher VO2max values than the Eritrean runners (77.2 ± 5.2 vs 73.5 ± 6.0 mL · kg-1 · min-1, P = .011, effect sizes [ES] = 0.65), although Eritrean runners were more economical at 19 km/h (191.4 ± 10.4 vs 205.9 ± 13.3 mL · kg-1 · min-1, P = .026, ES = 1.21). There were no differences between groups for ground-contact time, swing time, stride length, or stride frequency at any speed. Swing time was associated with running economy at 21 km/h in the Eritrean runners (r = .71, P = .033), but no other significant association was found between RE and biomechanical variables. Finally, best 10-km performance was significantly correlated with RE (r = -.57; P = .013). Eritrean runners have superior RE compared with elite European runners. This appears to offset their inferior VO2max. However, the current data suggest that their better RE does not have a biomechanical basis. Other factors, not measured in the current study, may contribute to this RE advantage.
Wynn, Melissa L; Clemente, Christofer; Nasir, Ami Fadhillah Amir Abdul; Wilson, Robbie S
2015-02-01
Movement speed is fundamental to all animal behaviour, yet no general framework exists for understanding why animals move at the speeds they do. Even during fitness-defining behaviours like running away from predators, an animal should select a speed that balances the benefits of high speed against the increased probability of mistakes. In this study, we explored this idea by quantifying trade-offs between speed, manoeuvrability and motor control in wild northern quolls (Dasyurus hallucatus) - a medium-sized carnivorous marsupial native to northern Australia. First, we quantified how running speed affected the probability of crashes when rounding corners of 45, 90 and 135 deg. We found that the faster an individual approached a turn, the higher the probability that they would crash, and these risks were greater when negotiating tighter turns. To avoid crashes, quolls modulated their running speed when they moved through turns of varying angles. Average speed for quolls when sprinting along a straight path was around 4.5 m s(-1) but this decreased linearly to speeds of around 1.5 m s(-1) when running through 135 deg turns. Finally, we explored how an individual's morphology affects their manoeuvrability. We found that individuals with larger relative foot sizes were more manoeuvrable than individuals with smaller relative foot sizes. Thus, movement speed, even during extreme situations like escaping predation, should be based on a compromise between high speed, manoeuvrability and motor control. We advocate that optimal - rather than maximal - performance capabilities underlie fitness-defining behaviours such as escaping predators and capturing prey. © 2015. Published by The Company of Biologists Ltd.
Pearse, Aaron T.; Brandt, David; Krapu, Gary
2016-01-01
Numerous wind energy projects have been constructed in the central and southern Great Plains, USA, the main wintering area for midcontinental Sandhill Cranes (Grus canadensis). In an initial assessment of the potential risks of wind towers to cranes, we estimated spatial overlap, investigated potential avoidance behavior, and determined the habitat associations of cranes. We used data from cranes marked with platform transmitting terminals (PTTs) with and without global positioning system (GPS) capabilities. We estimated the wintering distributions of PTT-marked cranes prior to the construction of wind towers, which we compared with current tower locations. Based on this analysis, we found 7% spatial overlap between the distributions of cranes and towers. When we looked at individually marked cranes, we found that 52% would have occurred within 10 km of a tower at some point during winter. Using data from cranes marked after tower construction, we found a potential indication of avoidance behavior, whereby GPS-marked cranes generally used areas slightly more distant from existing wind towers than would be expected by chance. Results from a habitat selection model suggested that distances between crane locations and towers may have been driven more by habitat selection than by avoidance, as most wind towers were constructed in locations not often selected by wintering cranes. Our findings of modest regional overlap and that few towers have been placed in preferred crane habitat suggest that the current distribution of wind towers may be of low risk to the continued persistence of wintering midcontinental Sandhill Cranes in the central and southern Great Plains.
Berk, S G; Gunderson, J H; Newsome, A L; Farone, A L; Hayes, B J; Redding, K S; Uddin, N; Williams, E L; Johnson, R A; Farsian, M; Reid, A; Skimmyhorn, J; Farone, M B
2006-12-01
Many species of bacteria pathogenic to humans, such as Legionella, are thought to have evolved in association with amoebal hosts. Several novel unculturable bacteria related to Legionella have also been found in amoebae, a few of which have been thought to be causes of nosocomial infections in humans. Because amoebae can be found in cooling towers, we wanted to know whether cooling tower environments might enhance the association between amoebae and bacterial pathogens of amoebae in order to identify potential "hot spots" for emerging human pathogens. To compare occurrence of infected amoebae in natural environments with those in cooling towers, 40 natural aquatic environments and 40 cooling tower samples were examined. Logistic regression analysis determined variables that were significant predictors of the occurrence of infected amoebae, which were found in 22 of 40 cooling tower samples but in only 3 of the 40 natural samples. An odds ratio showed that it is over 16 times more likely to encounter infected amoebae in cooling towers than in natural environments. Environmental data from cooling towers and natural habitats combined revealed dissolved organic carbon (DOC) and pH were predictors of the occurrence of the pathogens, however, when cooling tower data alone were analyzed, no variables accounted for the occurrence. Several bacteria have novel rRNA sequences, and most strains were not culturable outside of amoebae. Such pathogens of amoebae may spread to the environment via aerosols from cooling towers. Studies of emerging infectious diseases should strongly consider cooling towers as a source of amoeba-associated pathogens.
10. VIEW OF ANTENNA TOWER S111 FROM THE NORTHEAST SIDE ...
10. VIEW OF ANTENNA TOWER S-111 FROM THE NORTHEAST SIDE LOOKING UP. A PARABLOIC ANTENNA MOUNTED ON THE TOWER IS LOCATED IN THE LOWER LEFT OF PHOTO. - U.S. Naval Base, Pearl Harbor, Lualualei Radio Transmitter, Edison & Tower Drives, Pearl City, Honolulu County, HI
14 CFR 170.13 - Airport Traffic Control Tower (ATCT) establishment criteria.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Airport Traffic Control Tower (ATCT... AIR TRAFFIC CONTROL SERVICES AND NAVIGATIONAL FACILITIES Airport Traffic Control Towers § 170.13 Airport Traffic Control Tower (ATCT) establishment criteria. (a) The following criteria along with general...
WATER SPOTTERS: Water, energy, isotopes and experiential learning in the Colorado Front Range
NASA Astrophysics Data System (ADS)
Noone, D. C.; Berkelhammer, M. B.; Raudzens Bailey, A.; Buhr, S. M.; Smith, L. K.
2011-12-01
Providing students with tangible examples of the two-way interaction between human society and the climate system is a pressing challenge. Water is at the core of many issues in environmental change from local to global scales. In climate research, there are significant uncertainties in the role water plays in the climate system. "Water" can also act as a central theme that provides opportunities for science education at all levels. WATER SPOTTERS takes advantage of the prominent agricultural landscape of the region, which is a poignant example of how society influences the climate through irrigation, evaporation/transpiration and run-off and whose productivity is influenced by the climate system. Both natural grasslands and alpine ecosystems in the surrounding regions serve as examples of the native landscape. The centerpiece of this project is a 300m tower that is fully implemented with gas sampling lines and micrometeorological equipment to study the energy and water budgets of the region. Middle Schools that surround this site, many of which exist in visual contact with the tall tower, are provided with meteorological stations, which provide rainfall rates, temperature, humidity and radiation data. In coordination with the St Vrain Valley School District MESA (Math Engineering Science Achievement) program, students collect rain water samples that are analyzed and used as a core component of the research goals. The students use the weather stations as a way to directly explore their local climatology and provide data that is needed in research. We present an overview of the curriculum goals and associated physical infrastructure designed for middle school students in the Colorado Front Range to explore their local water cycle using water isotopes. The fixed infrastructure at the schools and tall tower are supplemented by mobile instruments such as an automated precipitation collector and snowflake photography system, which both fulfill science needs and provide opportunities for experiential learning.
Desai, Ankur R
2014-02-01
Significant advances have been made over the past decades in capabilities to simulate diurnal and seasonal variation of leaf-level and canopy-scale photosynthesis in temperate and boreal forests. However, long-term prediction of future forest productivity in a changing climate may be more dependent on how climate and biological anomalies influence extremes in interannual to decadal variability of canopy ecosystem carbon exchanges. These exchanges can differ markedly from leaf level responses, especially owing to the prevalence of long lags in nutrient and water cycling. Until recently, multiple long-term (10+ year) high temporal frequency (daily) observations of canopy exchange were not available to reliably assess this claim. An analysis of one of the longest running North American eddy covariance flux towers reveals that single climate variables do not adequately explain carbon exchange anomalies beyond the seasonal timescale. Daily to weekly lagged anomalies of photosynthesis positively autocorrelate with daily photosynthesis. This effect suggests a negative feedback in photosynthetic response to climate extremes, such as anomalies in evapotranspiration and maximum temperature. Moisture stress in the prior season did inhibit photosynthesis, but mechanisms are difficult to assess. A complex interplay of integrated and lagged productivity and moisture-limiting factors indicate a critical role of seasonal thresholds that limit growing season length and peak productivity. These results lead toward a new conceptual framework for improving earth system models with long-term flux tower observations.
Unified Research on Network-Based Hard/Soft Information Fusion
2016-02-02
types). There are a number of search tree run parameters which must be set depending on the experimental setting. A pilot study was run to identify...Unlimited Final Report: Unified Research on Network-Based Hard/Soft Information Fusion The views, opinions and/or findings contained in this report...Final Report: Unified Research on Network-Based Hard/Soft Information Fusion Report Title The University at Buffalo (UB) Center for Multisource
NASA Technical Reports Server (NTRS)
Wilkerson, Gary W.; Pitalo, Stephen K.
1999-01-01
Different secondary mirror support towers were modeled on the CODE V optical design/analysis program for the NGST Optical Telescope Assembly (OTA) B. The vertices of the NGST OTA B primary and secondary mirrors were separated by close to 9.0 m. One type of tower consisted of a hollow cone 6.0 m long, 2.00 m in diameter at the base, and 0.704 m in diameter at its top. The base of the cone was considered attached to the primary's reaction structure through a hole in the primary. Extending up parallel to the optical axis from the top of this cylinder were eight blades (pyramidal struts) 3.0 m long. A cross section of each these long blades was an isosceles triangle with a base of 0.010 m and a height of 0.100 m with the sharpest part of each triangle pointing inward. The eight struts occurred every 45 deg. The other type of tower was purely a hexapod arrangement and had no blades or cones. The hexapod consisted simply of six, very thin, circular struts, leaving in pairs at 12:00, 4:00, and 8:00 at the primary and traversing to the outer edge of the back of the secondary mount. At this mount, two struts arrived at each of 10:00, 2:00, and 6:00. The struts were attached to the primary mirror in a ring 3.5 m in diameter. They reached the back of the secondary mount, a circle 0.704 m in diameter. Transmittance analyses at two levels were performed on the secondary mirror support towers. Detailed transmittances were accomplished by the use of the CODE V optical design/analysis program and were compared to transmittance calculations that were almost back-of-the-envelope. Point spread function (PSF) calculations, including both diffraction and aberration effects, were performed on CODE V. As one goes out from the center of the blur (for a point source), the two types of support towers showed little difference between their PSF intensities until one reaches about the 3% level. Contours can be delineated on CODE V down to about 10 (exp -8) times the peak intensity, fine detailing the differences in the wings of the PSF. Between the first type of tower and the hexapod tower, below 3% of the peak intensity, the PSF contour maps well delineated significant differences in the outer portions of the PSFS. Such differences in the wings of the PSF significantly impact the resolution of brown dwarfs or extra solar planets from their star. The hexapod tower provided the best PSF.
2014-06-30
VANDENBERG AIR FORCE BASE, Calif. – The mobile service tower has been rolled back from the United Launch Alliance Delta II rocket carrying NASA's Orbiting Carbon Observatory-2, or OCO-2, on Space Launch Complex 2 at Vandenberg Air Force Base in California, one of the final steps leading up to launch. Launch is scheduled for 5:56 a.m. EDT on July 1. OCO-2 is NASA’s first mission dedicated to studying atmospheric carbon dioxide, the leading human-produced greenhouse gas driving changes in Earth’s climate. OCO-2 will provide a new tool for understanding the human and natural sources of carbon dioxide emissions and the natural "sinks" that absorb carbon dioxide and help control its buildup. The observatory will measure the global geographic distribution of these sources and sinks and study their changes over time. To learn more about OCO-2, visit http://www.nasa.gov/oco2. Photo credit: NASA/Randy Beaudoin
2014-06-30
VANDENBERG AIR FORCE BASE, Calif. – The mobile service tower has been rolled back from the United Launch Alliance Delta II rocket carrying NASA's Orbiting Carbon Observatory-2, or OCO-2, on Space Launch Complex 2 at Vandenberg Air Force Base in California, one of the final steps leading up to launch. Launch is scheduled for 5:56 a.m. EDT on July 1. OCO-2 is NASA’s first mission dedicated to studying atmospheric carbon dioxide, the leading human-produced greenhouse gas driving changes in Earth’s climate. OCO-2 will provide a new tool for understanding the human and natural sources of carbon dioxide emissions and the natural "sinks" that absorb carbon dioxide and help control its buildup. The observatory will measure the global geographic distribution of these sources and sinks and study their changes over time. To learn more about OCO-2, visit http://www.nasa.gov/oco2. Photo credit: NASA/Kim Shiflett
2014-06-30
VANDENBERG AIR FORCE BASE, Calif. – Final preparations are underway for the launch of NASA's Orbiting Carbon Observatory-2, or OCO-2, aboard a United Launch Alliance Delta II rocket, following rollback of the mobile service tower on Space Launch Complex 2 on Vandenberg Air Force Base in California. Launch is scheduled for 5:56 a.m. EDT on July 1. OCO-2 is NASA’s first mission dedicated to studying atmospheric carbon dioxide, the leading human-produced greenhouse gas driving changes in Earth’s climate. OCO-2 will provide a new tool for understanding the human and natural sources of carbon dioxide emissions and the natural "sinks" that absorb carbon dioxide and help control its buildup. The observatory will measure the global geographic distribution of these sources and sinks and study their changes over time. To learn more about OCO-2, visit http://www.nasa.gov/oco2. Photo credit: NASA/Kim Shiflett
2014-06-30
VANDENBERG AIR FORCE BASE, Calif. – Final preparations are underway for the launch of NASA's Orbiting Carbon Observatory-2, or OCO-2, aboard a United Launch Alliance Delta II rocket, following rollback of the mobile service tower on Space Launch Complex 2 on Vandenberg Air Force Base in California. Launch is scheduled for 5:56 a.m. EDT on July 1. OCO-2 is NASA’s first mission dedicated to studying atmospheric carbon dioxide, the leading human-produced greenhouse gas driving changes in Earth’s climate. OCO-2 will provide a new tool for understanding the human and natural sources of carbon dioxide emissions and the natural "sinks" that absorb carbon dioxide and help control its buildup. The observatory will measure the global geographic distribution of these sources and sinks and study their changes over time. To learn more about OCO-2, visit http://www.nasa.gov/oco2. Photo credit: NASA/Randy Beaudoin
Irving, David B.; Finn, James E.; Larson, James P.
1995-01-01
We began a three year study in 1987 to test the feasibility of using sonar in the Togiak River to estimate salmon escapements. Current methods rely on periodic aerial surveys and a counting tower at river kilometer 97. Escapement estimates are not available until 10 to 14 days after the salmon enter the river. Water depth and turbidity preclude relocating the tower to the lower river and affect the reliability of aerial surveys. To determine whether an alternative method could be developed to improve the timeliness and accuracy of current escapement monitoring, Bendix sonar units were operated during 1987, 1988, and 1990. Two sonar stations were set up opposite each other at river kilometer 30 and were operated 24 hours per day, seven days per week. Catches from gill nets with 12, 14, and 20 cm stretch mesh, a beach seine, and visual observations were used to estimate species composition. Length and sex data were collected from salmon caught in the nets to assess sampling bias.In 1987, sonar was used to select optimal sites and enumerate coho salmon. In 1988 and 1990, the sites identified in 1987 were used to estimate the escapement of five salmon species. Sockeye salmon escapement was estimated at 512,581 and 589,321, chinook at 7,698 and 15,098, chum at 246,144 and 134,958, coho at 78,588 and 28,290, and pink at 96,167 and 131,484. Sonar estimates of sockeye salmon were two to three times the Alaska Department of Fish and Game's escapement estimate based on aerial surveys and tower counts. The source of error was probably a combination of over-estimating the total number of targets counted by the sonar and by incorrectly estimating species composition.Total salmon escapement estimates using sonar may be feasible but several more years of development are needed. Because of the overlapped salmon run timing, estimating species composition appears the most difficult aspect of using sonar for management. Possible improvements include using a larger beach seine or selecting gill net mesh sizes evenly spaced between 10 and 20 cm stretch mesh.Salmon counts at river kilometer 30 would reduce the lag time between salmon river entry and the escapement estimate to 2-5 days. Any further decrease in lag time, however, would require moving the sonar operations downriver into less desirable braided portions of the river.
Update on the Purdue University 2-second Drop Tower
NASA Astrophysics Data System (ADS)
Collicott, Steven
A small drop tower of approximately one second drop duration was built in the School of Aero-nautics and Astronautics at Purdue University beginning in 1998 and operated until summer 2007. This inexpensive tower in an old airplane hanger, was built largely by Yongkang Chen, now a Research Professor at Portland State University in Oregon, USA. In about 7 years of operations, the tower generated sufficient science results for Chen's PhD thesis[1] (summarized in three AIAA Journal papers[2-4]), Fitzpatrick's MS thesis[5], two industry projects for since-canceled advanced rodent habitats for ISS, and one project for NASA Marshall. In addition to the science use, Purdue undergraduate students designed, built, and performed simpler fluids experiments for their own career advancement, including a novel investigation of the impact of imperfect repeatability of initial conditions on a zero-g fluids experiment. The tower was also used for outreach to school children. It is most satisfying that Chen's PhD research in this small tower, and subsequent discussions and interactions, helped Weislogel to propose the two Vane Gap tests in his highly successful Capillary Fluids Experiment (CFE) in the International Space Station in 2006 and 2007[6]. Chen as been involved in the remodeling of these two Vane Gap cylinders for subsequent re-launch to ISS for a second round of experiments expected in 2010 and 2011. In August 2007 the School of Aeronautics and Astronautics at Purdue University moved into the new Neil Armstrong Hall of Engineering and construction on a new 2-second drop tower began. A vertical shaft of nearly 23 meters was designed into the building. An approximately 80 m2 general-use fluids lab is at the top level, and a small access room of approximately 9 m2 is at the bottom. However, construction of the new $57M building created only the space for the science facility, not the science facility itself. The science facility is under construction and this paper presents an update on progress for the micro-gravity community. The most noticeable current activity is testing of the air-bag decelerator. The tower is one that will use a free-falling experiment inside of a drag shield to avoid most aerodynamic drag. The airbag is designed from experiences of others yet the small, triangular room in which the tower terminates imposes challenges. The airbag is approximately 1.5m diameter and 1.5m tall. Initial testing led to a desire to increase vent area, and just this week the bag has returned from the shop that was modifying it. On-board computer, battery packs, lighting, and cameras have been acquired. Thanks to Lockheed Martin, one camera is 500 frames per second with 1.3 million 12-bit gray scale pixels per frame. The Spincraft company donated steel hemisphere-cylinders to serve as the nose of the drag shield. Wind tunnel and CFD modeling of the drag shield has been performed by Purdue undergraduate aerospace students. Currently the drag shield structure and experiment package structure are being design and analyzed. The experiment volume is approximately a cylinder 0.45m diameter and 0.6m tall. Tower operation is intended to commence in fall 2010 with inert package drops at full mass and full height. Developing the operations procedures, especially operational safety, are the goals of this work. First science is then expected in the winter. References 1. Y. Chen, "A Study of Capillary Flow in a Vane-wall Gap in Zero Gravity," Ph.D. thesis, School of Aeronautics and Astronautics, Purdue University. August 2003. 2. Y. Chen and S. H. Collicott, "Investigation of the Symmetric Wetting of a Vane-Wall Gap in Propellant Tanks," AIAA Journal, 42, No. 2, pp. 305-314, February 2004. 3. Y. Chen, and S. H. Collicott, "Experimental Study on the Capillary Flow in a Vane-Wall Gap Geometry," AIAA Journal, 43, No. 11, pp. 2395-2403, November, 2005. 4. Y. Chen and S. H. Collicott, "Study of Wetting in an Asymmetrical Vane-Wall Gap in Propellant Tanks," AIAA Journal, 44, 4, pp. 859-867, April 2006. 5. S. L. Fitzpatrick, "A Study of Hydrogen Peroxide Low-Gravity Control for Propellant Management Devices," MS thesis, School of Aeronautics and Astronautics, Purdue Uni-versity. May 2003. 6. M. M. Weislogel, R. Jenson, Y. Chen, S. H. Collicott, J. Klatte, and M. Dreyer. "The capillary flow experiments aboard the International Space Station: Status". Acta Astro-nautica. 65:861-869, 2009
2016-08-21
less pronounced for pelvis velocity • Seat velocity and dynamic displacement not recorded for this test series – Would provide key information for...effectiveness of seat – Displacement /time history data should be recorded for all future test series UNCLASSIFIED UNCLASSIFIED Conclusions/Future...interfacing with seat manufacturers to broaden occupant protection range – Record dynamic stroke on all drop tower tests to evaluate correlation between displacement rate and lumbar compression UNCLASSIFIED UNCLASSIFIED 17
Multi-scale Modeling of Energy Balance Fluxes in a Dense Tamarisk Riparian Forest
NASA Astrophysics Data System (ADS)
Neale, C. M.; Santos, C. A.; Watts, D.; Osterberg, J.; Hipps, L. E.; Sritharan, S. I.
2008-12-01
Remote sensing of energy balance fluxes has become operationally more viable over the last 10 years with the development of more robust multi-layer models and the availability of quasi-real time satellite imagery from most sensors. Riparian corridors in semi-arid and arid areas present a challenge to satellite based techniques for estimating evapotranspiration due to issues of scale and pixel resolution, especially when using the thermal infrared bands. This paper will present energy balance measurement and modeling results over a Salt Cedar (Tamarix Ramosissima) forest in the Cibola National Wildlife Refuge along the Colorado River south of Blythe, CA. The research site encompasses a 600 hectare area populated by mostly Tamarisk stands of varying density. Three Bowen ratio systems are installed on tall towers within varying densities of forest cover in the upwind footprint and growing under varying depths to the water table. An additional eddy covariance tower is installed alongside a Bowen ratio system on one of the towers. Flux data has been gathered continuously since early 2007. In the summer of 2007, a Scintec large aperture scintillometer was installed between two of the towers over 1 km apart and has been working continuously along with the flux towers. Two intensive field campaigns were organized in June 2007 and May 2008 to coincide with LANDSAT TM5, MODIS and ASTER overpasses. High resolution multispectral and thermal imagery was acquired at the same time with the USU airborne system to provide information for the up- scaling of the energy balance fluxes from tower to satellite scales. The paper will present comparisons between the different energy balance measuring techniques under the highly advective conditions of the experimental site, concentrating on the scintillometer data. Preliminary results of remotely sensed modeling of the fluxes at different scales and model complexity will also be presented.
Assessing and correcting spatial representativeness of tower eddy-covariance flux measurements
NASA Astrophysics Data System (ADS)
Metzger, S.; Xu, K.; Desai, A. R.; Taylor, J. R.; Kljun, N.; Blanken, P.; Burns, S. P.; Scott, R. L.
2014-12-01
Estimating the landscape-scale exchange of ecologically relevant trace gas and energy fluxes from tower eddy-covariance (EC) measurements is often complicated by surface heterogeneity. For example, a tower EC measurement may represent less than 1% of a grid cell resolved by mechanistic models (order 100-1000 km2). In particular for data assimilation or comparison with large-scale observations, it is hence critical to assess and correct the spatial representativeness of tower EC measurements. We present a procedure that determines from a single EC tower the spatio-temporally explicit flux field of its surrounding. The underlying principle is to extract the relationship between biophysical drivers and ecological responses from measurements under varying environmental conditions. For this purpose, high-frequency EC flux processing and source area calculations (≈60 h-1) are combined with remote sensing retrievals of land surface properties and subsequent machine learning. Methodological details are provided in our companion presentation "Towards the spatial rectification of tower-based eddy-covariance flux observations". We apply the procedure to one year of data from each of four AmeriFlux sites under different climate and ecological environments: Lost Creek shrub fen wetland, Niwot Ridge subalpine conifer, Park Falls mixed forest, and Santa Rita mesquite savanna. We find that heat fluxes from the Park Falls 122-m-high EC measurement and from a surrounding 100 km2 target area differ up to 100 W m-2, or 65%. Moreover, 85% and 24% of the EC flux observations are adequate surrogates of the mean surface-atmosphere exchange and its spatial variability across a 900 km2 target area, respectively, at 5% significance and 80% representativeness levels. Alternatively, the resulting flux grids can be summarized as probability density functions, and used to inform mechanistic models directly with the mean flux value and its spatial variability across a model grid cell. Lastly, for each site we evaluate the applicability of the procedure based on a full bottom-up uncertainty budget.
Cultivation of E. coli in single- and ten-stage tower-loop reactors.
Adler, I; Schügerl, K
1983-02-01
E. Coli was cultivated in batch and continuous operations in the presence of an antifoam agent in stirred-tank and in single- and ten-stage airlift tower reactors with an outer loop. The maximum specific growth rate, mu(m), the substrate yield coefficient, Y(x/s), the respiratory quotient, RQ, substrate conversion, U(s), the volumetric mass transfer coefficient, K(L)a, the specific interfacial area, a, and the specific power input, P/V(L), were measured and compared. If a medium is used with a concentration of complex substrates (extracts) 2.5 times higher than that of glucose, a spectrum of C sources is available and cell regulation influences reactor performance. Both mu(m) and Y(X/S), which were evaluated in batch reactors, cannot be used for continuous reactors or, when measured in stirred-tank reactors, cannot be employed for tower-loop reactors: mu(m) is higher in the stirred-tank batch than in the tower-loop batch reactor, mu(m) and Y(x/s) are higher in the continuous reactor than in the batch single-stage tower-loop reactor. The performance of the single-stage is better than that of the ten-stage reactor due to the inefficient trays employed. A reduction of the medium recirculation rate reduces OTR, U(s), Pr, and Y(X/S) and causes cell sedimentation and flocculation. The volumetric mass transfer coefficient is reduced with increasing cultivation time; the Sauter bubble diameter, d(s), remains constant and does not depend on operational conditions. An increase in the medium recirculation rate reduces k(L)a. The specific power input, P/V(L), for the single-stage tower loop is much lower with the same k(L)a value than for a stirred tank. The relationship k(L)a vs. P/V(L) evaluated for model media in stirred tanks, can also be used for cultivations in these reactors.
Social Models Enhance Apes' Memory for Novel Events.
Howard, Lauren H; Wagner, Katherine E; Woodward, Amanda L; Ross, Stephen R; Hopper, Lydia M
2017-01-20
Nonhuman primates are more likely to learn from the actions of a social model than a non-social "ghost display", however the mechanism underlying this effect is still unknown. One possibility is that live models are more engaging, drawing increased attention to social stimuli. However, recent research with humans has suggested that live models fundamentally alter memory, not low-level attention. In the current study, we developed a novel eye-tracking paradigm to disentangle the influence of social context on attention and memory in apes. Tested in two conditions, zoo-housed apes (2 gorillas, 5 chimpanzees) were familiarized to videos of a human hand (social condition) and mechanical claw (non-social condition) constructing a three-block tower. During the memory test, subjects viewed side-by-side pictures of the previously-constructed block tower and a novel block tower. In accordance with looking-time paradigms, increased looking time to the novel block tower was used to measure event memory. Apes evidenced memory for the event featuring a social model, though not for the non-social condition. This effect was not dependent on attention differences to the videos. These findings provide the first evidence that, like humans, social stimuli increase nonhuman primates' event memory, which may aid in information transmission via social learning.
Social Models Enhance Apes’ Memory for Novel Events
Howard, Lauren H.; Wagner, Katherine E.; Woodward, Amanda L.; Ross, Stephen R.; Hopper, Lydia M.
2017-01-01
Nonhuman primates are more likely to learn from the actions of a social model than a non-social “ghost display”, however the mechanism underlying this effect is still unknown. One possibility is that live models are more engaging, drawing increased attention to social stimuli. However, recent research with humans has suggested that live models fundamentally alter memory, not low-level attention. In the current study, we developed a novel eye-tracking paradigm to disentangle the influence of social context on attention and memory in apes. Tested in two conditions, zoo-housed apes (2 gorillas, 5 chimpanzees) were familiarized to videos of a human hand (social condition) and mechanical claw (non-social condition) constructing a three-block tower. During the memory test, subjects viewed side-by-side pictures of the previously-constructed block tower and a novel block tower. In accordance with looking-time paradigms, increased looking time to the novel block tower was used to measure event memory. Apes evidenced memory for the event featuring a social model, though not for the non-social condition. This effect was not dependent on attention differences to the videos. These findings provide the first evidence that, like humans, social stimuli increase nonhuman primates’ event memory, which may aid in information transmission via social learning. PMID:28106098
Stability of large horizontal-axis axisymmetric wind turbines. Ph.D. Thesis - Delaware Univ.
NASA Technical Reports Server (NTRS)
Hirschbein, M. S.; Young, M. I.
1980-01-01
The stability of large horizontal axis, axi-symmetric, power producing wind turbines was examined. The analytical model used included the dynamic coupling of the rotor, tower and power generating system. The aerodynamic loading was derived from blade element theory. Each rotor blade was permitted tow principal elastic bending degrees of freedom, one degree of freedom in torsion and controlled pitch as a rigid body. The rotor hub was mounted in a rigid nacelle which may yaw freely or in a controlled manner. The tower can bend in two principal directions and may twist. Also, the rotor speed can vary and may induce perturbation reactions within the power generating equipment. Stability was determined by the eigenvalues of a set of linearized constant coefficient differential equations. All results presented are based on a 3 bladed, 300 ft. diameter, 2.5 megawatt wind turbine. Some of the parameters varied were; wind speed, rotor speed structural stiffness and damping, the effective stiffness and damping of the power generating system and the principal bending directions of the rotor blades. Unstable or weakly stable behavior can be caused by aerodynamic forces due to motion of the rotor blades and tower in the plane of rotation or by mechanical coupling between the rotor system and the tower.
Carbon Nanotube Tower-Based Supercapacitor
NASA Technical Reports Server (NTRS)
Meyyappan, Meyya (Inventor)
2012-01-01
A supercapacitor system, including (i) first and second, spaced apart planar collectors, (ii) first and second arrays of multi-wall carbon nanotube (MWCNT) towers or single wall carbon nanotube (SWCNT) towers, serving as electrodes, that extend between the first and second collectors where the nanotube towers are grown directly on the collector surfaces without deposition of a catalyst and without deposition of a binder material on the collector surfaces, and (iii) a porous separator module having a transverse area that is substantially the same as the transverse area of at least one electrode, where (iv) at least one nanotube tower is functionalized to permit or encourage the tower to behave as a hydrophilic structure, with increased surface wettability.
1999-10-14
KENNEDY SPACE CENTER, FLA. -- Live TV trucks (far right) from local channels merge at the site of the fallen Mobile Service Tower (MST) and umbilical tower nearby after their demolition. The towers were demolished to make room for Lockheed Martin's 14-acre Vehicle Integration Facility (VIF), under construction. Weighing two million pounds, the umbilical tower was approximately 200 feet high. The taller 300-foot MST weighed five million pounds. About 200 pounds of linear-shaped charges were used to bring down the towers so that the materials can be recycled. The implosion and removal of the tower debris is expected to be completed in two months. The VIF will be used for Lockheed Martin's Atlas V Launch System.
1999-10-14
KENNEDY SPACE CENTER, FLA. -- Live TV trucks from local channels merge at the site of the fallen Mobile Service Tower (MST) and umbilical tower nearby after their demolition. The towers were demolished to make room for Lockheed Martin's 14-acre Vehicle Integration Facility (VIF), under construction. Weighing two million pounds, the umbilical tower was approximately 200 feet high. The taller 300-foot MST weighed five million pounds. About 200 pounds of linear-shaped charges were used to bring down the towers so that the materials can be recycled. The implosion and removal of the tower debris is expected to be completed in two months. The VIF will be used for Lockheed Martin's Atlas V Launch System.
the Cryogenic Underground Observatory for Rare Events: Status and Prospects
Alduino, C.; Alfonso, K.; Artusa, D. R.; ...
2017-05-09
The Cryogenic Underground Observatory for Rare Events (CUORE) is a large-scale double beta decay experiment utilizing cryogenic bolometers that is currently being commissioned at the Gran Sasso National Laboratory (LNGS) in Italy. Its primary focus is to search for the neutrinoless double beta decay of 130Te with a projected sensitivity to Majorana neutrino masses near the inverted mass hierarchy region. The detector is composed of 988 5x5x5-cm 3 TeO 2 crystals of natural isotopic composition arranged in 19 towers of 52 crystals each, all housed in a common dilution refrigerator. A single CUORE-like tower, CUORE-0, was assembled and operated asmore » a stand-alone detector for a period of approximately two years. In this report, the results from CUORE-0 and the current status and physics potential of CUORE are presented.« less
Multiple impacts of dusty projectiles
NASA Astrophysics Data System (ADS)
Kothe, Stefan; Güttler, Carsten; Blum, Jurgen
In the context of early stages of planetesimal formation we performed laboratory and drop tower experiments to study multiple impacts of small dust-aggregate projectiles into solid sintered dust targets. Both collision partners consisted of 1.5 µm monodisperse spherical SiO2 monomers with volume filling factors of 0.15 (projectiles) and 0.35 (targets), respectively. The fragile projectiles were accelerated by a solenoid accelerator with a linear projectile magazine, which enabled us to perform 25 impacts within 4.5 s of microgravity time in the Bremen drop tower. We measured the mass-accretion efficiency for different impact velocities between 3 and 5 m s-1 , using an analytical balance and imaging methods. Furthermore, we observed random collisions among small dust aggregates with sizes around 1 mm and collision velocities of the order of 0.25 m s-1 and used them to improve the dust-aggregate collision model of Güttler et al. (2010). u
Large outbreak of Legionnaires' disease and Pontiac fever at a military base.
Ambrose, J; Hampton, L M; Fleming-Dutra, K E; Marten, C; McClusky, C; Perry, C; Clemmons, N A; McCormic, Z; Peik, S; Mancuso, J; Brown, E; Kozak, N; Travis, T; Lucas, C; Fields, B; Hicks, L; Cersovsky, S B
2014-11-01
We investigated a mixed outbreak of Legionnaires' disease (LD) and Pontiac fever (PF) at a military base to identify the outbreak's environmental source as well as known legionellosis risk factors. Base workers with possible legionellosis were interviewed and, if consenting, underwent testing for legionellosis. A retrospective cohort study collected information on occupants of the buildings closest to the outbreak source. We identified 29 confirmed and probable LD and 38 PF cases. All cases were exposed to airborne pathogens from a cooling tower. Occupants of the building closest to the cooling tower were 6·9 [95% confidence interval (CI) 2·2-22·0] and 5·5 (95% CI 2·1-14·5) times more likely to develop LD and PF, respectively, than occupants of the next closest building. Thorough preventive measures and aggressive responses to outbreaks, including searching for PF cases in mixed legionellosis outbreaks, are essential for legionellosis control.
DIME Students Share Comments About Experiments
NASA Technical Reports Server (NTRS)
2002-01-01
Students discuss fine points of their final design for the drop tower experiment during the second Dropping in a Microgravity Environment (DIME) competition held April 23-25, 2002, at NASA's Glenn Research Center. Competitors included two teams from Sycamore High School, Cincinnati, OH, and one each from Bay High School, Bay Village, OH, and COSI Academy, Columbus, OH. DIME is part of NASA's education and outreach activities. Details are on line at http://microgravity.grc.nasa.gov/DIME_2002.html.
Field Evaluation of a Passive Sampling Device for Hydrazines in Ambient Air
1990-04-06
MANIDIFUIOFOBELFO Figure 2. Test gas generator schematic. Conditioned house- compressed air is used as the diluent. The conditioning procedure consists...of passing the house air through a series of demisters, a hot Hopcalite catalyst bed, a reciprocating dual-tower molecular sieve scrubber, and finally... Air P. A. TAFFE,* S. W. BROWN,** A. R. THUROW,*** J. C. TRAvIs**** *GEO-Centers Inc., **EG&G, BOC-022, KSC, FL . . F. ***Wiltech Corp., KSC, FL MAY 0
2003-08-14
KENNEDY SPACE CENTER, FLA. - In the mobile service tower on Launch Pad 17-B, Cape Canaveral Air Force Station, workers move the first half of the fairing around the Space Infrared Telescope Facility (SIRTF) behind it for encapsulation. SIRTF will obtain images and spectra by detecting the infrared energy, or heat, radiated by objects in space. Consisting of a 0.85-meter telescope and three cryogenically cooled science instruments, SIRTF will be the largest infrared telescope ever launched into space. It is the fourth and final element in NASA’s family of orbiting “Great Observatories.” Its highly sensitive instruments will give a unique view of the Universe and peer into regions of space that are hidden from optical telescopes.
2003-08-14
KENNEDY SPACE CENTER, FLA. - In the mobile service tower on Launch Pad 17-B, Cape Canaveral Air Force Station, the top of the fairing is seen as it moves into place around the Space Infrared Telescope Facility (SIRTF). SIRTF will obtain images and spectra by detecting the infrared energy, or heat, radiated by objects in space. Consisting of a 0.85-meter telescope and three cryogenically cooled science instruments, SIRTF will be the largest infrared telescope ever launched into space. It is the fourth and final element in NASA’s family of orbiting “Great Observatories.” Its highly sensitive instruments will give a unique view of the Universe and peer into regions of space that are hidden from optical telescopes.
2003-08-14
KENNEDY SPACE CENTER, FLA. - In the mobile service tower on Launch Pad 17-B, Cape Canaveral Air Force Station, the first half of the fairing is moved around the Space Infrared Telescope Facility (SIRTF). SIRTF will obtain images and spectra by detecting the infrared energy, or heat, radiated by objects in space. Consisting of a 0.85-meter telescope and three cryogenically cooled science instruments, SIRTF will be the largest infrared telescope ever launched into space. It is the fourth and final element in NASA’s family of orbiting “Great Observatories.” Its highly sensitive instruments will give a unique view of the Universe and peer into regions of space that are hidden from optical telescopes.
2003-08-14
KENNEDY SPACE CENTER, FLA. - In the mobile service tower on Launch Pad 17-B, Cape Canaveral Air Force Station, the first half of the fairing (background) moves toward the Space Infrared Telescope Facility (foreground) for encapsulation. SIRTF will obtain images and spectra by detecting the infrared energy, or heat, radiated by objects in space. Consisting of a 0.85-meter telescope and three cryogenically cooled science instruments, SIRTF will be the largest infrared telescope ever launched into space. It is the fourth and final element in NASA’s family of orbiting “Great Observatories.” Its highly sensitive instruments will give a unique view of the Universe and peer into regions of space that are hidden from optical telescopes.
2003-08-14
KENNEDY SPACE CENTER, FLA. - In the mobile service tower on Launch Pad 17-B, Cape Canaveral Air Force Station, workers watch as the first half of the fairing moves closer around the Space Infrared Telescope Facility (SIRTF). SIRTF will obtain images and spectra by detecting the infrared energy, or heat, radiated by objects in space. Consisting of a 0.85-meter telescope and three cryogenically cooled science instruments, SIRTF will be the largest infrared telescope ever launched into space. It is the fourth and final element in NASA’s family of orbiting “Great Observatories.” Its highly sensitive instruments will give a unique view of the Universe and peer into regions of space that are hidden from optical telescopes.
2003-08-10
KENNEDY SPACE CENTER, FLA. - Before dawn, the Space Infrared Telescope Facility (SIRTF) arrives at Launch Pad 17-B, Cape Canaveral Air Force Station, where it will be lifted into the mobile service tower and prepared for launch. SIRTF consists of three cryogenically cooled science instruments and an 0.85-meter telescope, and is one of NASA’s largest infrared telescopes to be launched. It is the fourth and final element in NASA’s family of orbiting “Great Observatories.” SIRTF will obtain images and spectra by detecting the infrared energy, or heat, radiated by objects in space. Most of this infrared radiation is blocked by the Earth's atmosphere and cannot be observed from the ground.
2003-08-10
KENNEDY SPACE CENTER, FLA. - After dawn, the Space Infrared Telescope Facility (SIRTF) is lifted up the mobile service tower on Launch Pad 17-B, Cape Canaveral Air Force Station. SIRTF will be attached to the Delta II rocket and encapsulated in its fairing before launch. Consisting of three cryogenically cooled science instruments and an 0.85-meter telescope, SIRTF is one of NASA’s largest infrared telescopes to be launched. It is the fourth and final element in NASA’s family of orbiting “Great Observatories.” SIRTF will obtain images and spectra by detecting the infrared energy, or heat, radiated by objects in space. Most of this infrared radiation is blocked by the Earth's atmosphere and cannot be observed from the ground.
Gu, Yingxin; Wylie, Bruce K.; Bliss, Norman B.
2013-01-01
This study assessed and described a relationship between satellite-derived growing season averaged Normalized Difference Vegetation Index (NDVI) and annual productivity for grasslands within the Greater Platte River Basin (GPRB) of the United States. We compared growing season averaged NDVI (GSN) with Soil Survey Geographic (SSURGO) database rangeland productivity and flux tower Gross Primary Productivity (GPP) for grassland areas. The GSN was calculated for each of nine years (2000–2008) using the 7-day composite 250-m eMODIS (expedited Moderate Resolution Imaging Spectroradiometer) NDVI data. Strong correlations exist between the nine-year mean GSN (MGSN) and SSURGO annual productivity for grasslands (R2 = 0.74 for approximately 8000 pixels randomly selected from eight homogeneous regions within the GPRB; R2 = 0.96 for the 14 cluster-averaged points). Results also reveal a strong correlation between GSN and flux tower growing season averaged GPP (R2 = 0.71). Finally, we developed an empirical equation to estimate grassland productivity based on the MGSN. Spatially explicit estimates of grassland productivity over the GPRB were generated, which improved the regional consistency of SSURGO grassland productivity data and can help scientists and land managers to better understand the actual biophysical and ecological characteristics of grassland systems in the GPRB. This final estimated grassland production map can also be used as an input for biogeochemical, ecological, and climate change models.
30. VIEW OF THE WESTERN SIDEWALK ON PIER 5, SHOWING ...
30. VIEW OF THE WESTERN SIDEWALK ON PIER 5, SHOWING DEDICATION PLAQUE ON EASTERN PIER TOWER, LOOKING EAST - West End-North Side Bridge, Spanning Ohio River, approximately 1 mile downstream from confluence of Monongahela & Allegheny rivers, Pittsburgh, Allegheny County, PA
Haeusler, Karl Georg; Herm, Juliane; Kunze, Claudia; Krüll, Matthias; Brechtel, Lars; Lock, Jürgen; Hohenhaus, Marc; Heuschmann, Peter U; Fiebach, Jochen B; Haverkamp, Wilhelm; Endres, Matthias; Jungehulsing, Gerhard Jan
2012-08-31
Regular exercise is beneficial for cardiovascular health but a recent meta-analysis indicated a relationship between extensive endurance sport and a higher risk of atrial fibrillation, an independent risk factor for stroke. However, data on the frequency of cardiac arrhythmias or (clinically silent) brain lesions during and after marathon running are missing. In the prospective observational "Berlin Beat of Running" study experienced endurance athletes underwent clinical examination (CE), 3 Tesla brain magnetic resonance imaging (MRI), carotid ultrasound imaging (CUI) and serial blood sampling (BS) within 2-3 days prior (CE, MRI, CUI, BS), directly after (CE, BS) and within 2 days after (CE, MRI, BS) the 38th BMW BERLIN-MARATHON 2011. All participants wore a portable electrocardiogram (ECG)-recorder throughout the 4 to 5 days baseline study period. Participants with pathological MRI findings after the marathon, troponin elevations or detected cardiac arrhythmias will be asked to undergo cardiac MRI to rule out structural abnormalities. A follow-up is scheduled after one year. Here we report the baseline data of the enrolled 110 athletes aged 36-61 years. Their mean age was 48.8 ± 6.0 years, 24.5% were female, 8.2% had hypertension and 2.7% had hyperlipidaemia. Participants have attended a mean of 7.5 ± 6.6 marathon races within the last 5 years and a mean of 16 ± 36 marathon races in total. Their weekly running distance prior to the 38th BMW BERLIN-MARATHON was 65 ± 17 km. Finally, 108 (98.2%) Berlin Beat-Study participants successfully completed the 38th BMW BERLIN-MARATHON 2011. Findings from the "Berlin Beats of Running" study will help to balance the benefits and risks of extensive endurance sport. ECG-recording during the marathon might contribute to identify athletes at risk for cardiovascular events. MRI results will give new insights into the link between physical stress and brain damage. clinicaltrials.gov NCT01428778.
The influence of liquid-gas velocity ratio on the noise of the cooling tower
NASA Astrophysics Data System (ADS)
Yang, Bin; Liu, Xuanzuo; Chen, Chi; Zhao, Zhouli; Song, Jinchun
2018-05-01
The noise from the cooling tower has a great influence on psychological performance of human beings. The cooling tower noise mainly consists of fan noise, falling water noise and mechanical noise. This thesis used DES turbulence model with FH-W model to simulate the flow and sound pressure field in cooling tower based on CFD software FLUENT and analyzed the influence of different kinds noise, which affected by diverse factors, on the cooling tower noise. It can be concluded that the addition of cooling water can reduce the turbulence and vortex noise of the rotor fluid field in the cooling tower at some extent, but increase the impact noise of the liquid-gas two phase. In general, the cooling tower noise decreases with the velocity ratio of liquid to gas increasing, and reaches the lowest when the velocity ratio of liquid to gas is close to l.
Chen, Bo; Guo, Wei-hua; Li, Peng-yun; Xie, Wen-ping
2014-01-01
This paper presented an overview on the dynamic analysis and control of the transmission tower-line system in the past forty years. The challenges and future developing trends in the dynamic analysis and mitigation of the transmission tower-line system under dynamic excitations are also put forward. It also reviews the analytical models and approaches of the transmission tower, transmission lines, and transmission tower-line systems, respectively, which contain the theoretical model, finite element (FE) model and the equivalent model; shows the advances in wind responses of the transmission tower-line system, which contains the dynamic effects under common wind loading, tornado, downburst, and typhoon; and discusses the dynamic responses under earthquake and ice loads, respectively. The vibration control of the transmission tower-line system is also reviewed, which includes the magnetorheological dampers, friction dampers, tuned mass dampers, and pounding tuned mass dampers. PMID:25105161
Visibility analysis of fire lookout towers in the Boyabat State Forest Enterprise in Turkey.
Kucuk, Omer; Topaloglu, Ozer; Altunel, Arif Oguz; Cetin, Mehmet
2017-07-01
For a successful fire suppression, it is essential to detect and intervene forest fires as early as possible. Fire lookout towers are crucial assets in detecting forest fires, in addition to other technological advancements. In this study, we performed a visibility analysis on a network of fire lookout towers currently operating in a relatively fire-prone region in Turkey's Western Black Sea region. Some of these towers had not been functioning properly; it was proposed that these be taken out of the grid and replaced with new ones. The percentage of visible areas under the current network of fire lookout towers was 73%; it could rise to 81% with the addition of newly proposed towers. This study was the first research to conduct a visibility analysis of current and newly proposed fire lookout towers in the Western Black Sea region and focus on its forest fire problem.
77 FR 9700 - Utility Scale Wind Towers From China and Vietnam
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-17
...)] Utility Scale Wind Towers From China and Vietnam Determinations On the basis of the record \\1\\ developed... threatened with material injury by reason of imports from China of utility scale wind towers, provided for in... with material injury by reason of imports from Vietnam of utility scale wind towers, provided for in...
78 FR 10210 - Utility Scale Wind Towers From China and Vietnam
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-13
...)] Utility Scale Wind Towers From China and Vietnam Determinations On the basis of the record \\1\\ developed... with material injury by reason of imports of utility scale wind towers from China and Vietnam, provided... of imports of utility scale wind towers from China and Vietnam. Commissioner Dean A. Pinkert...
Prueitt, Melvin L.
1996-01-01
Convection towers which are capable of cleaning the pollution from large quantities of air, of generating electricity, and of producing fresh water utilize the evaporation of water sprayed into the towers to create strong airflows and to remove pollution from the air. Turbines in tunnels at the skirt section of the towers generate electricity, and condensers produce fresh water.
Prueitt, Melvin L.
1995-01-01
Convection towers which are capable of cleaning the pollution from large quantities of air, of generating electricity, and of producing fresh water utilize the evaporation of water sprayed into the towers to create strong airflows and to remove pollution from the air. Turbines in tunnels at the skirt section of the towers generate electricity, and condensers produce fresh water.
Prueitt, M.L.
1996-01-16
Convection towers which are capable of cleaning the pollution from large quantities of air, of generating electricity, and of producing fresh water utilize the evaporation of water sprayed into the towers to create strong airflows and to remove pollution from the air. Turbines in tunnels at the skirt section of the towers generate electricity, and condensers produce fresh water. 6 figs.
14 CFR 139.329 - Pedestrians and ground vehicles.
Code of Federal Regulations, 2010 CFR
2010-01-01
... by an employee, tenant, or contractor; (c) When an air traffic control tower is in operation, ensure... between the tower and the pedestrian, vehicle, or escort; (d) When an air traffic control tower is not in operation, or there is no air traffic control tower, provide adequate procedures to control pedestrians and...
15. GENERAL EASTERN VIEW OF LINDE 1000 TONS PER DAY ...
15. GENERAL EASTERN VIEW OF LINDE 1000 TONS PER DAY HIGH PURITY OXYGEN MAKING PLANT SHOWING TWIN OXYGEN FRACTIONATING TOWER (ON RIGHT), VERMICULITE STORAGE TOWERS (ON LEFT FOREGROUND), AND AN ARGON FRACTIONATING TOWER (BEHIND VERMICULITE STORAGE TOWER). - U.S. Steel Duquesne Works, Fuel & Utilities Plant, Along Monongahela River, Duquesne, Allegheny County, PA