Sample records for fingers

  1. Variable and Asymmetric Range of Enslaving: Fingers Can Act Independently over Small Range of Flexion

    PubMed Central

    van den Noort, Josien C.; van Beek, Nathalie; van der Kraan, Thomas; Veeger, DirkJan H. E. J.; Stegeman, Dick F.; Veltink, Peter H.; Maas, Huub

    2016-01-01

    The variability in the numerous tasks in which we use our hands is very large. However, independent movement control of individual fingers is limited. To assess the extent of finger independency during full-range finger flexion including all finger joints, we studied enslaving (movement in non-instructed fingers) and range of independent finger movement through the whole finger flexion trajectory in single and multi-finger movement tasks. Thirteen young healthy subjects performed single- and multi-finger movement tasks under two conditions: active flexion through the full range of movement with all fingers free to move and active flexion while the non-instructed finger(s) were restrained. Finger kinematics were measured using inertial sensors (PowerGlove), to assess enslaving and range of independent finger movement. Although all fingers showed enslaving movement to some extent, highest enslaving was found in adjacent fingers. Enslaving effects in ring and little finger were increased with movement of additional, non-adjacent fingers. The middle finger was the only finger affected by restriction in movement of non-instructed fingers. Each finger showed a range of independent movement before the non-instructed fingers started to move, which was largest for the index finger. The start of enslaving was asymmetrical for adjacent fingers. Little finger enslaving movement was affected by multi-finger movement. We conclude that no finger can move independently through the full range of finger flexion, although some degree of full independence is present for smaller movements. This range of independent movement is asymmetric and variable between fingers and between subjects. The presented results provide insight into the role of finger independency for different types of tasks and populations. PMID:27992598

  2. Finger tapping ability in healthy elderly and young adults.

    PubMed

    Aoki, Tomoko; Fukuoka, Yoshiyuki

    2010-03-01

    The maximum isometric force production capacity of the fingers decreases with age. However, little information is available on age-related changes in dynamic motor capacity of individual fingers. The purpose of this study was to compare the dynamic motor function of individual fingers between elderly and young adults using rapid single-finger and double-finger tapping. Fourteen elderly and 14 young adults performed maximum frequency tapping by the index, middle, ring, or little finger (single-finger tapping) and with alternate movements of the index-middle, middle-ring, or ring-little finger-pair (double-finger tapping). The maximum pinch force between the thumb and each finger, tactile sensitivity of each fingertip, and time taken to complete a pegboard test were also measured. Compared with young subjects, the older subjects had significantly slower tapping rates in all fingers and finger-pairs in the tapping tasks. The age-related decline was also observed in the tactile sensitivities of all fingers and in the pegboard test. However, there was no group difference in the pinch force of any finger. The tapping rate of each finger did not correlate with the pinch force or tactile sensitivity for the corresponding finger in the elderly subjects. Maximum rate of finger tapping was lower in the elderly adults compared with the young adults. The decline of finger tapping ability in elderly adults seems to be less affected by their maximum force production capacities of the fingers as well as tactile sensitivities at the tips of the fingers.

  3. Hand digit control in children: motor overflow in multi-finger pressing force vector space during maximum voluntary force production.

    PubMed

    Shim, Jae Kun; Karol, Sohit; Hsu, Jeffrey; de Oliveira, Marcio Alves

    2008-04-01

    The aim of this study was to investigate the contralateral motor overflow in children during single-finger and multi-finger maximum force production tasks. Forty-five right handed children, 5-11 years of age produced maximum isometric pressing force in flexion or extension with single fingers or all four fingers of their right hand. The forces produced by individual fingers of the right and left hands were recorded and analyzed in four-dimensional finger force vector space. The results showed that increases in task (right) hand finger forces were linearly associated with non-task (left) hand finger forces. The ratio of the non-task hand finger force magnitude to the corresponding task hand finger force magnitude, termed motor overflow magnitude (MOM), was greater in extension than flexion. The index finger flexion task showed the smallest MOM values. The similarity between the directions of task hand and non-task hand finger force vectors in four-dimensional finger force vector space, termed motor overflow direction (MOD), was the greatest for index and smallest for little finger tasks. MOM of a four-finger task was greater than the sum of MOMs of single-finger tasks, and this phenomenon was termed motor overflow surplus. Contrary to previous studies, no single-finger or four-finger tasks showed significant changes of MOM or MOD with the age of children. We conclude that the contralateral motor overflow in children during finger maximum force production tasks is dependent upon the task fingers and the magnitude and direction of task finger forces.

  4. Finger Interdependence: Linking the Kinetic and Kinematic Variables

    PubMed Central

    Kim, Sun Wook; Shim, Jae Kun; Zatsiorsky, Vladimir M.; Latash, Mark L.

    2008-01-01

    We studied the dependence between voluntary motion of a finger and pressing forces produced by the tips of other fingers of the hand. Subjects moved one of the fingers (task finger) of the right hand trying to follow a cyclic, ramp-like flexion-extension template at different frequencies. The other fingers (slave fingers) were restricted from moving; their flexion forces were recorded and analyzed. Index finger motion caused the smallest force production by the slave fingers. Larger forces were produced by the neighbors of the task finger; these forces showed strong modulation over the range of motion of the task finger. The enslaved forces were higher during the flexion phase of the movement cycle as compared to the extension phase. The index of enslaving expressed in N/rad was higher when the task finger moved through the more flexed postures. The dependence of enslaving on both range and direction of task finger motion poses problems for methods of analysis of finger coordination based on an assumption of universal matrices of finger inter-dependence. PMID:18255182

  5. Design and preliminary evaluation of the FINGER rehabilitation robot: controlling challenge and quantifying finger individuation during musical computer game play.

    PubMed

    Taheri, Hossein; Rowe, Justin B; Gardner, David; Chan, Vicki; Gray, Kyle; Bower, Curtis; Reinkensmeyer, David J; Wolbrecht, Eric T

    2014-02-04

    This paper describes the design and preliminary testing of FINGER (Finger Individuating Grasp Exercise Robot), a device for assisting in finger rehabilitation after neurologic injury. We developed FINGER to assist stroke patients in moving their fingers individually in a naturalistic curling motion while playing a game similar to Guitar Hero. The goal was to make FINGER capable of assisting with motions where precise timing is important. FINGER consists of a pair of stacked single degree-of-freedom 8-bar mechanisms, one for the index and one for the middle finger. Each 8-bar mechanism was designed to control the angle and position of the proximal phalanx and the position of the middle phalanx. Target positions for the mechanism optimization were determined from trajectory data collected from 7 healthy subjects using color-based motion capture. The resulting robotic device was built to accommodate multiple finger sizes and finger-to-finger widths. For initial evaluation, we asked individuals with a stroke (n = 16) and without impairment (n = 4) to play a game similar to Guitar Hero while connected to FINGER. Precision design, low friction bearings, and separate high speed linear actuators allowed FINGER to individually actuate the fingers with a high bandwidth of control (-3 dB at approximately 8 Hz). During the tests, we were able to modulate the subject's success rate at the game by automatically adjusting the controller gains of FINGER. We also used FINGER to measure subjects' effort and finger individuation while playing the game. Test results demonstrate the ability of FINGER to motivate subjects with an engaging game environment that challenges individuated control of the fingers, automatically control assistance levels, and quantify finger individuation after stroke.

  6. Integration of tactile input across fingers in a patient with finger agnosia.

    PubMed

    Anema, Helen A; Overvliet, Krista E; Smeets, Jeroen B J; Brenner, Eli; Dijkerman, H Chris

    2011-01-01

    Finger agnosia has been described as an inability to explicitly individuate between the fingers, which is possibly due to fused neural representations of these fingers. Hence, are patients with finger agnosia unable to keep tactile information perceived over several fingers separate? Here, we tested a finger agnosic patient (GO) on two tasks that measured the ability to keep tactile information simultaneously perceived by individual fingers separate. In experiment 1 GO performed a haptic search task, in which a target (the absence of a protruded line) needed to be identified among distracters (protruded lines). The lines were presented simultaneously to the fingertips of both hands. Similarly to the controls, her reaction time decreased when her fingers were aligned as compared to when her fingers were stretched and in an unaligned position. This suggests that she can keep tactile input from different fingers separate. In experiment two, GO was required to judge the position of a target tactile stimulus to the index finger, relatively to a reference tactile stimulus to the middle finger, both in fingers uncrossed and crossed position. GO was able to indicate the relative position of the target stimulus as well as healthy controls, which indicates that she was able to keep tactile information perceived by two neighbouring fingers separate. Interestingly, GO performed better as compared to the healthy controls in the finger crossed condition. Together, these results suggest the GO is able to implicitly distinguish between tactile information perceived by multiple fingers. We therefore conclude that finger agnosia is not caused by minor disruptions of low-level somatosensory processing. These findings further underpin the idea of a selective impaired higher order body representation restricted to the fingers as underlying cause of finger agnosia. Copyright © 2010 Elsevier Ltd. All rights reserved.

  7. Design and preliminary evaluation of the FINGER rehabilitation robot: controlling challenge and quantifying finger individuation during musical computer game play

    PubMed Central

    2014-01-01

    Background This paper describes the design and preliminary testing of FINGER (Finger Individuating Grasp Exercise Robot), a device for assisting in finger rehabilitation after neurologic injury. We developed FINGER to assist stroke patients in moving their fingers individually in a naturalistic curling motion while playing a game similar to Guitar Hero®a. The goal was to make FINGER capable of assisting with motions where precise timing is important. Methods FINGER consists of a pair of stacked single degree-of-freedom 8-bar mechanisms, one for the index and one for the middle finger. Each 8-bar mechanism was designed to control the angle and position of the proximal phalanx and the position of the middle phalanx. Target positions for the mechanism optimization were determined from trajectory data collected from 7 healthy subjects using color-based motion capture. The resulting robotic device was built to accommodate multiple finger sizes and finger-to-finger widths. For initial evaluation, we asked individuals with a stroke (n = 16) and without impairment (n = 4) to play a game similar to Guitar Hero® while connected to FINGER. Results Precision design, low friction bearings, and separate high speed linear actuators allowed FINGER to individually actuate the fingers with a high bandwidth of control (−3 dB at approximately 8 Hz). During the tests, we were able to modulate the subject’s success rate at the game by automatically adjusting the controller gains of FINGER. We also used FINGER to measure subjects’ effort and finger individuation while playing the game. Conclusions Test results demonstrate the ability of FINGER to motivate subjects with an engaging game environment that challenges individuated control of the fingers, automatically control assistance levels, and quantify finger individuation after stroke. PMID:24495432

  8. Development of cylindrical-type finger force measuring system using force sensors and its characteristics evaluation

    NASA Astrophysics Data System (ADS)

    Kim, Hyeon-Min; Yoon, Joungwon; Shin, Hee-Suk; Kim, Gab-Soon

    2012-02-01

    Some patients cannot use their hands because of the paralysis of their fingers. Their fingers can recover with rehabilitative training, and the extent of rehabilitation can be judged by grasping a cylindrical-object with their fingers. At present, the cylindrical-object used in hospitals is only a plastic cylinder, which cannot measure grasping force of the fingers. Therefore, doctors must judge the extent of rehabilitation by watching patients' fingers as they grasp the plastic cylinder. In this paper, the development of two cylindrical-type finger force measuring systems with four force sensors for left hand and right hand were developed. The developed finger force measuring system can measure the grasping force of patients' each finger (forefinger, middle finger, ring finger and little finger), and the measured results could be used to judge the rehabilitation extent of a finger patient. The grasping force tests of men and women were performed using the developed cylindrical-type finger force measuring systems. The tests confirm that the average finger forces of right hand and left hand for men were about 194 N and 179 N, and for women, 108 N and 95 N.

  9. [Treatment of trigger finger with located needle knife].

    PubMed

    Zhang, Qi-Feng; Yang, Jiang; Xi, Sheng-Hua

    2016-07-25

    To investigate the clinical effects of located needle knife in the treatment of trigger finger. The clinical data of 133 patients(145 fingers) with trigger finger underwent treatment with located needle knife from September 2010 to March 2014 were retrospectively analyzed. There were 37 males(40 fingers) and 96 females (105 fingers), aged from 18 to 71 years old with a mean of 51.8 years. Course of disease was from 1 to 19 months with an average of 8.2 months. Affected fingers included 82 thumbs, 12 index fingers, 11 middle fingers, 36 ring fingers, and 4 little fingers. According to the standard of Quinnell grade, 42 fingers were grade III, 92 fingers were grade IV, and 11 fingers were grade V. Firstly the double pipe gab was put into the distal edge of hypertrophic tendon sheath, then small knife needle was used to release the sheath proximally along the tendon line direction. The informations of wound healing and nerve injury, postoperative finger function, finger pain at 6 months were observed. The operation time was from 8 to 25 min with an average of 9.8 min. All the patients were followed up from 6 to 26 months with an average of 12.5 months. No complications such as the wound inflammation and seepage, vascular or nerve injuries were found. According to the standard of Quinnell grade, 123 fingers got excellent results, 15 good, 7 poor. It's a good choice to treat trigger finger with located needle knife in advantage of minimal invasion, simple safe operation, and it should be promoted in clinic.

  10. An estimation of finger-tapping rates and load capacities and the effects of various factors.

    PubMed

    Ekşioğlu, Mahmut; İşeri, Ali

    2015-06-01

    The aim of this study was to estimate the finger-tapping rates and finger load capacities of eight fingers (excluding thumbs) for a healthy adult population and investigate the effects of various factors on tapping rate. Finger-tapping rate, the total number of finger taps per unit of time, can be used as a design parameter of various products and also as a psychomotor test for evaluating patients with neurologic problems. A 1-min tapping task was performed by 148 participants with maximum volitional tempo for each of eight fingers. For each of the tapping tasks, the participant with the corresponding finger tapped the associated key in the standard position on the home row of a conventional keyboard for touch typing. The index and middle fingers were the fastest fingers for both hands, and little fingers the slowest. All dominant-hand fingers, except little finger, had higher tapping rates than the fastest finger of the nondominant hand. Tapping rate decreased with age and smokers tapped faster than nonsmokers. Tapping duration and exercise had also significant effect on tapping rate. Normative data of tapping rates and load capacities of eight fingers were estimated for the adult population. In designs of psychomotor tests that require the use of tapping rate or finger load capacity data, the effects of finger, age, smoking, and tapping duration need to be taken into account. The findings can be used for ergonomic designs requiring finger-tapping capacity and also as a reference in psychomotor tests. © 2015, Human Factors and Ergonomics Society.

  11. Perceiving fingers in single-digit arithmetic problems.

    PubMed

    Berteletti, Ilaria; Booth, James R

    2015-01-01

    In this study, we investigate in children the neural underpinnings of finger representation and finger movement involved in single-digit arithmetic problems. Evidence suggests that finger representation and finger-based strategies play an important role in learning and understanding arithmetic. Because different operations rely on different networks, we compared activation for subtraction and multiplication problems in independently localized finger somatosensory and motor areas and tested whether activation was related to skill. Brain activations from children between 8 and 13 years of age revealed that only subtraction problems significantly activated finger motor areas, suggesting reliance on finger-based strategies. In addition, larger subtraction problems yielded greater somatosensory activation than smaller problems, suggesting a greater reliance on finger representation for larger numerical values. Interestingly, better performance in subtraction problems was associated with lower activation in the finger somatosensory area. Our results support the importance of fine-grained finger representation in arithmetical skill and are the first neurological evidence for a functional role of the somatosensory finger area in proficient arithmetical problem solving, in particular for those problems requiring quantity manipulation. From an educational perspective, these results encourage investigating whether different finger-based strategies facilitate arithmetical understanding and encourage educational practices aiming at integrating finger representation and finger-based strategies as a tool for instilling stronger numerical sense.

  12. Perceiving fingers in single-digit arithmetic problems

    PubMed Central

    Berteletti, Ilaria; Booth, James R.

    2015-01-01

    In this study, we investigate in children the neural underpinnings of finger representation and finger movement involved in single-digit arithmetic problems. Evidence suggests that finger representation and finger-based strategies play an important role in learning and understanding arithmetic. Because different operations rely on different networks, we compared activation for subtraction and multiplication problems in independently localized finger somatosensory and motor areas and tested whether activation was related to skill. Brain activations from children between 8 and 13 years of age revealed that only subtraction problems significantly activated finger motor areas, suggesting reliance on finger-based strategies. In addition, larger subtraction problems yielded greater somatosensory activation than smaller problems, suggesting a greater reliance on finger representation for larger numerical values. Interestingly, better performance in subtraction problems was associated with lower activation in the finger somatosensory area. Our results support the importance of fine-grained finger representation in arithmetical skill and are the first neurological evidence for a functional role of the somatosensory finger area in proficient arithmetical problem solving, in particular for those problems requiring quantity manipulation. From an educational perspective, these results encourage investigating whether different finger-based strategies facilitate arithmetical understanding and encourage educational practices aiming at integrating finger representation and finger-based strategies as a tool for instilling stronger numerical sense. PMID:25852582

  13. Activity patterns of extrinsic finger flexors and extensors during movements of instructed and non-instructed fingers.

    PubMed

    van Beek, Nathalie; Stegeman, Dick F; van den Noort, Josien C; H E J Veeger, DirkJan; Maas, Huub

    2018-02-01

    The fingers of the human hand cannot be controlled fully independently. This phenomenon may have a neurological as well as a mechanical basis. Despite previous studies, the neuromechanics of finger movements are not fully understood. The aims of this study were (1) to assess the activation and coactivation patterns of finger specific flexor and extensor muscle regions during instructed single finger flexion and (2) to determine the relationship between enslaved finger movements and respective finger muscle activation. In 9 healthy subjects (age 22-29), muscle activation was assessed during single finger flexion using a 90 surface electromyography electrode grid placed over the flexor digitorum superficialis (FDS) and the extensor digitorum (ED). We found (1) no significant differences in muscle activation timing between fingers, (2) considerable muscle activity in flexor and extensor regions associated with the non-instructed fingers and (3) no correlation between the muscle activations and corresponding movement of non-instructed fingers. A clear disparity was found between the movement pattern of the non-instructed fingers and the activity pattern of the corresponding muscle regions. This suggests that mechanical factors, such as intertendinous and myofascial connections, may also affect finger movement independency and need to be taken into consideration when studying finger movement. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Stabilization of the total force in multi-finger pressing tasks studied with the ‘inverse piano’ technique

    PubMed Central

    Martin, J.R.; Budgeon, M.K.; Zatsiorsky, V.M.; Latash, M.L.

    2010-01-01

    When one finger changes its force, other fingers of the hand can show unintended force changes in the same direction (enslaving) and in the opposite direction (error compensation). We tested a hypothesis that externally imposed changes in finger force predominantly lead to error compensation effects in other fingers thus stabilizing the total force. A novel device, the “inverse piano”, was used to impose controlled displacements to one of the fingers over different magnitudes and at different rates. Subjects (n =10) pressed with four fingers at a constant force level and then one of the fingers was unexpectedly raised. The subjects were instructed not to interfere with possible changes in the finger forces. Raising a finger caused an increase in its force and a drop in the force of the other three fingers. Overall, total force showed a small increase. Larger force drops were seen in neighbors of the raised finger (proximity effect). The results show that multi-finger force stabilizing synergies dominate during involuntary reactions to externally imposed finger force changes. Within the referent configuration hypothesis, the data suggest that the instruction “not to interfere” leads to adjustments of the referent coordinates of all the individual fingers. PMID:21450360

  15. Mallet finger - aftercare

    MedlinePlus

    Baseball finger - aftercare; Drop finger - aftercare; Avulsion fracture - mallet finger - aftercare ... away from the rest of the bone (avulsion fracture) Mallet finger most often occurs when something hits ...

  16. Patterns of Dupuytren disease in fingers: studying correlations with a multivariate ordinal logit model.

    PubMed

    Lanting, Rosanne; Nooraee, Nazanin; Werker, Paul M N; van den Heuvel, Edwin R

    2014-09-01

    Dupuytren disease affects fingers in a variable fashion. Knowledge about specific disease patterns (phenotype) based on location and severity of the disease is lacking. In this cross-sectional study, 344 primary affected hands with Dupuytren disease were physically examined. The Pearson correlation coefficient between the coexistence of Dupuytren disease in pairs of fingers was calculated, and agglomerative hierarchical clustering was applied to identify possible clusters of affected fingers. With a multivariate ordinal logit model, the authors studied the correlation on severity, taking into account age and sex, and tested hypotheses on independence between groups of fingers. The ring finger was most frequently affected by Dupuytren disease, and contractures were seen in 15.1 percent of affected rays. The severity of thumb and index finger, middle and ring fingers, and middle and little fingers was significantly correlated. Occurrences in pairs of fingers were highest in the middle and ring fingers and lowest in the thumb and index finger. Correlation between the ring and little fingers and a correlation between fingers from the ulnar and radial sides could not be demonstrated. Rays on the ulnar side of the hand are predominantly affected. The middle finger is substantially correlated with other fingers on the ulnar side, and the thumb and index finger are correlated; however, there was no evidence that the ulnar side and the radial side were correlated in any way, which suggests that occurrence on one side of the hand does not predict Dupuytren disease on the other side of the hand. Risk, III.

  17. Adaptive flexibility of the within-hand attentional gradient in touch: An MEG study.

    PubMed

    Kida, Tetsuo; Tanaka, Emi; Kakigi, Ryusuke

    2018-06-21

    Previous studies have demonstrated the cortical mechanisms for the gradient of spatial attention in vision and audition, whereas those for touch have yet to be elucidated in detail. In order to examine the within-hand gradient of tactile spatial attention in the cerebral cortex, we used magnetoencephalography (MEG) to record cortical responses to an electrocutaneous stimulation presented randomly to any of the five fingers of the right hand at a random interstimulus interval (750-1250 ms). Participants attended to the index finger, ring finger, or both to detect a rare target stimulus in a sequence of frequent standard stimuli presented to the attended finger(s) by silent counting. Neuromagnetic responses around the contralateral primary and secondary somatosensory cortices (SIc and SIIc) at 50-70 ms and 80-100 ms, respectively, for the stimulation of the index or ring finger were stronger when that finger was attended than when the distant finger was attended or at rest. The amplitude of the SIIc response was also intermediate when the index and ring fingers were simultaneously attended. The SIIc response to the task-irrelevant stimulation of the thumb or little finger increased when the index or ring finger was attended, respectively, suggesting an across-finger gradient of tactile attention. Simultaneous attention to the index and ring fingers decreased the SIIc response to the task-irrelevant stimulation of the intervening middle finger more than that with attention to either one of the two fingers. The earliest attentional sign was observed for the SI M40c response, with the amplitude increasing with the stimulation of the unattended finger. Furthermore, late responses in the temporo-parietal junction (TPJ) and prefrontal cortex (PFC) were stronger with the stimulation of the unattended finger than with that of the attended finger. Thus, the present study provides cortical evidence for the adaptive control of the within-hand, across-finger gradient of tactile attention that depends on whether attention is focused on a single finger or divided into non-adjacent different fingers. Copyright © 2018. Published by Elsevier Inc.

  18. Finger wear detection for production line battery tester

    DOEpatents

    Depiante, Eduardo V.

    1997-01-01

    A method for detecting wear in a battery tester probe. The method includes providing a battery tester unit having at least one tester finger, generating a tester signal using the tester fingers and battery tester unit with the signal characteristic of the electrochemical condition of the battery and the tester finger, applying wavelet transformation to the tester signal including computing a mother wavelet to produce finger wear indicator signals, analyzing the signals to create a finger wear index, comparing the wear index for the tester finger with the index for a new tester finger and generating a tester finger signal change signal to indicate achieving a threshold wear change.

  19. Scattering Removal for Finger-Vein Image Restoration

    PubMed Central

    Yang, Jinfeng; Zhang, Ben; Shi, Yihua

    2012-01-01

    Finger-vein recognition has received increased attention recently. However, the finger-vein images are always captured in poor quality. This certainly makes finger-vein feature representation unreliable, and further impairs the accuracy of finger-vein recognition. In this paper, we first give an analysis of the intrinsic factors causing finger-vein image degradation, and then propose a simple but effective image restoration method based on scattering removal. To give a proper description of finger-vein image degradation, a biological optical model (BOM) specific to finger-vein imaging is proposed according to the principle of light propagation in biological tissues. Based on BOM, the light scattering component is sensibly estimated and properly removed for finger-vein image restoration. Finally, experimental results demonstrate that the proposed method is powerful in enhancing the finger-vein image contrast and in improving the finger-vein image matching accuracy. PMID:22737028

  20. Selective recruitment of single motor units in human flexor digitorum superficialis muscle during flexion of individual fingers.

    PubMed

    Butler, T J; Kilbreath, S L; Gorman, R B; Gandevia, S C

    2005-08-15

    Flexor digitorum superficialis (FDS) is an extrinsic multi-tendoned muscle which flexes the proximal interphalangeal joints of the four fingers. It comprises four digital components, each with a tendon that inserts onto its corresponding finger. To determine the degree to which these digital components can be selectively recruited by volition, we recorded the activity of a single motor unit in one component via an intramuscular electrode while the subject isometrically flexed each of the remaining fingers, one at a time. The finger on which the unit principally acted was defined as the 'test finger' and that which flexed isometrically was the 'active' finger. Activity in 79 units was recorded. Isometric finger flexion forces of 50% maximum voluntary contraction (MVC) activated less than 50% of single units in components of FDS acting on fingers that were not voluntarily flexed. With two exceptions, the median recruitment threshold for all active-test finger combinations involving the index, middle, ring and little finger test units was between 49 and 60% MVC (60% MVC being the value assigned to those not recruited). The exceptions were flexion of the little finger while recording from ring finger units (median: 40% MVC), and vice versa (median: 2% MVC). For all active-test finger combinations, only 35/181 units were activated when the active finger flexed at less than 20% MVC, and the fingers were adjacent for 28 of these. Functionally, to recruit FDS units during grasping and lifting, relatively heavy objects were required, although systematic variation occurred with the width of the object. In conclusion, FDS components can be selectively activated by volition and this may be especially important for grasping at high forces with one or more fingers.

  1. Finger posture modulates structural body representations

    PubMed Central

    Tamè, Luigi; Dransfield, Elanah; Quettier, Thomas; Longo, Matthew R.

    2017-01-01

    Patients with lesions of the left posterior parietal cortex commonly fail in identifying their fingers, a condition known as finger agnosia, yet are relatively unimpaired in sensation and skilled action. Such dissociations have traditionally been interpreted as evidence that structural body representations (BSR), such as the body structural description, are distinct from sensorimotor representations, such as the body schema. We investigated whether performance on tasks commonly used to assess finger agnosia is modulated by changes in hand posture. We used the ‘in between’ test in which participants estimate the number of unstimulated fingers between two touched fingers or a localization task in which participants judge which two fingers were stimulated. Across blocks, the fingers were placed in three levels of splay. Judged finger numerosity was analysed, in Exp. 1 by direct report and in Exp. 2 as the actual number of fingers between the fingers named. In both experiments, judgments were greater when non-adjacent stimulated fingers were positioned far apart compared to when they were close together or touching, whereas judgements were unaltered when adjacent fingers were stimulated. This demonstrates that BSRs are not fixed, but are modulated by the real-time physical distances between body parts. PMID:28223685

  2. Design and analysis of an underactuated anthropomorphic finger for upper limb prosthetics.

    PubMed

    Omarkulov, Nurdos; Telegenov, Kuat; Zeinullin, Maralbek; Begalinova, Ainur; Shintemirov, Almas

    2015-01-01

    This paper presents the design of a linkage based finger mechanism ensuring extended range of anthropomorphic gripping motions. The finger design is done using a path-point generation method based on geometrical dimensions and motion of a typical index human finger. Following the design description, and its kinematics analysis, the experimental evaluation of the finger gripping performance is presented using the finger 3D printed prototype. The finger underactuation is achieved by utilizing mechanical linkage system, consisting of two crossed four-bar linkage mechanisms. It is shown that the proposed finger design can be used to design a five-fingered anthropomorphic hand and has the potential for upper limb prostheses development.

  3. Finger wear detection for production line battery tester

    DOEpatents

    Depiante, E.V.

    1997-11-18

    A method is described for detecting wear in a battery tester probe. The method includes providing a battery tester unit having at least one tester finger, generating a tester signal using the tester fingers and battery tester unit with the signal characteristic of the electrochemical condition of the battery and the tester finger, applying wavelet transformation to the tester signal including computing a mother wavelet to produce finger wear indicator signals, analyzing the signals to create a finger wear index, comparing the wear index for the tester finger with the index for a new tester finger and generating a tester finger signal change signal to indicate achieving a threshold wear change. 9 figs.

  4. Differing Dynamics of Intrapersonal and Interpersonal Coordination: Two-finger and Four-Finger Tapping Experiments

    PubMed Central

    Kodama, Kentaro; Furuyama, Nobuhiro; Inamura, Tetsunari

    2015-01-01

    Finger-tapping experiments were conducted to examine whether the dynamics of intrapersonal and interpersonal coordination systems can be described equally by the Haken—Kelso—Bunz model, which describes inter-limb coordination dynamics. This article reports the results of finger-tapping experiments conducted in both systems. Two within-subject factors were investigated: the phase mode and the number of fingers. In the intrapersonal experiment (Experiment 1), the participants were asked to tap, paced by a gradually hastening auditory metronome, looking at their fingers moving, using the index finger in the two finger condition, or the index and middle finger in the four-finger condition. In the interpersonal experiment (Experiment 2), pairs of participants performed the task while each participant used the outside hand, tapping with the index finger in the two finger condition, or the index and middle finger in the four-finger condition. Some results did not agree with the HKB model predictions. First, from Experiment 1, no significant difference was observed in the movement stability between the in-phase and anti-phase modes in the two finger condition. Second, from Experiment 2, no significant difference was found in the movement stability between the in-phase and anti-phase mode in the four-finger condition. From these findings, different coordination dynamics were inferred between intrapersonal and interpersonal coordination systems against prediction from the previous studies. Results were discussed according to differences between intrapersonal and interpersonal coordination systems in the availability of perceptual information and the complexity in the interaction between limbs derived from a nested structure. PMID:26070119

  5. Transfer of tactile perceptual learning to untrained neighboring fingers reflects natural use relationships

    PubMed Central

    Harrar, Vanessa; Oliver, Jonathan; Johansen-Berg, Heidi; Spence, Charles

    2015-01-01

    Tactile learning transfers from trained to untrained fingers in a pattern that reflects overlap between the representations of fingers in the somatosensory system (e.g., neurons with multifinger receptive fields). While physical proximity on the body is known to determine the topography of somatosensory representations, tactile coactivation is also an established organizing principle of somatosensory topography. In this study we investigated whether tactile coactivation, induced by habitual inter-finger cooperative use (use pattern), shapes inter-finger overlap. To this end, we used psychophysics to compare the transfer of tactile learning from the middle finger to its adjacent fingers. This allowed us to compare transfer to two fingers that are both physically and cortically adjacent to the middle finger but have differing use patterns. Specifically, the middle finger is used more frequently with the ring than with the index finger. We predicted this should lead to greater representational overlap between the former than the latter pair. Furthermore, this difference in overlap should be reflected in differential learning transfer from the middle to index vs. ring fingers. Subsequently, we predicted temporary learning-related changes in the middle finger's representation (e.g., cortical magnification) would cause transient interference in perceptual thresholds of the ring, but not the index, finger. Supporting this, longitudinal analysis revealed a divergence where learning transfer was fast to the index finger but relatively delayed to the ring finger. Our results support the theory that tactile coactivation patterns between digits affect their topographic relationships. Our findings emphasize how action shapes perception and somatosensory organization. PMID:26631145

  6. Transfer of tactile perceptual learning to untrained neighboring fingers reflects natural use relationships.

    PubMed

    Dempsey-Jones, Harriet; Harrar, Vanessa; Oliver, Jonathan; Johansen-Berg, Heidi; Spence, Charles; Makin, Tamar R

    2016-03-01

    Tactile learning transfers from trained to untrained fingers in a pattern that reflects overlap between the representations of fingers in the somatosensory system (e.g., neurons with multifinger receptive fields). While physical proximity on the body is known to determine the topography of somatosensory representations, tactile coactivation is also an established organizing principle of somatosensory topography. In this study we investigated whether tactile coactivation, induced by habitual inter-finger cooperative use (use pattern), shapes inter-finger overlap. To this end, we used psychophysics to compare the transfer of tactile learning from the middle finger to its adjacent fingers. This allowed us to compare transfer to two fingers that are both physically and cortically adjacent to the middle finger but have differing use patterns. Specifically, the middle finger is used more frequently with the ring than with the index finger. We predicted this should lead to greater representational overlap between the former than the latter pair. Furthermore, this difference in overlap should be reflected in differential learning transfer from the middle to index vs. ring fingers. Subsequently, we predicted temporary learning-related changes in the middle finger's representation (e.g., cortical magnification) would cause transient interference in perceptual thresholds of the ring, but not the index, finger. Supporting this, longitudinal analysis revealed a divergence where learning transfer was fast to the index finger but relatively delayed to the ring finger. Our results support the theory that tactile coactivation patterns between digits affect their topographic relationships. Our findings emphasize how action shapes perception and somatosensory organization. Copyright © 2016 the American Physiological Society.

  7. Impact of Finger Type in Fingerprint Authentication

    NASA Astrophysics Data System (ADS)

    Gafurov, Davrondzhon; Bours, Patrick; Yang, Bian; Busch, Christoph

    Nowadays fingerprint verification system is the most widespread and accepted biometric technology that explores various features of the human fingers for this purpose. In general, every normal person has 10 fingers with different size. Although it is claimed that recognition performance with little fingers can be less accurate compared to other finger types, to our best knowledge, this has not been investigated yet. This paper presents our study on the topic of influence of the finger type into fingerprint recognition performance. For analysis we employ two fingerprint verification software packages (one public and one commercial). We conduct test on GUC100 multi sensor fingerprint database which contains fingerprint images of all 10 fingers from 100 subjects. Our analysis indeed confirms that performance with small fingers is less accurate than performance with the others fingers of the hand. It also appears that best performance is being obtained with thumb or index fingers. For example, performance deterioration from the best finger (i.e. index or thumb) to the worst fingers (i.e. small ones) can be in the range of 184%-1352%.

  8. Intensity Variation Normalization for Finger Vein Recognition Using Guided Filter Based Singe Scale Retinex

    PubMed Central

    Xie, Shan Juan; Lu, Yu; Yoon, Sook; Yang, Jucheng; Park, Dong Sun

    2015-01-01

    Finger vein recognition has been considered one of the most promising biometrics for personal authentication. However, the capacities and percentages of finger tissues (e.g., bone, muscle, ligament, water, fat, etc.) vary person by person. This usually causes poor quality of finger vein images, therefore degrading the performance of finger vein recognition systems (FVRSs). In this paper, the intrinsic factors of finger tissue causing poor quality of finger vein images are analyzed, and an intensity variation (IV) normalization method using guided filter based single scale retinex (GFSSR) is proposed for finger vein image enhancement. The experimental results on two public datasets demonstrate the effectiveness of the proposed method in enhancing the image quality and finger vein recognition accuracy. PMID:26184226

  9. Intensity Variation Normalization for Finger Vein Recognition Using Guided Filter Based Singe Scale Retinex.

    PubMed

    Xie, Shan Juan; Lu, Yu; Yoon, Sook; Yang, Jucheng; Park, Dong Sun

    2015-07-14

    Finger vein recognition has been considered one of the most promising biometrics for personal authentication. However, the capacities and percentages of finger tissues (e.g., bone, muscle, ligament, water, fat, etc.) vary person by person. This usually causes poor quality of finger vein images, therefore degrading the performance of finger vein recognition systems (FVRSs). In this paper, the intrinsic factors of finger tissue causing poor quality of finger vein images are analyzed, and an intensity variation (IV) normalization method using guided filter based single scale retinex (GFSSR) is proposed for finger vein image enhancement. The experimental results on two public datasets demonstrate the effectiveness of the proposed method in enhancing the image quality and finger vein recognition accuracy.

  10. Zinc finger proteins in cancer progression.

    PubMed

    Jen, Jayu; Wang, Yi-Ching

    2016-07-13

    Zinc finger proteins are the largest transcription factor family in human genome. The diverse combinations and functions of zinc finger motifs make zinc finger proteins versatile in biological processes, including development, differentiation, metabolism and autophagy. Over the last few decades, increasing evidence reveals the potential roles of zinc finger proteins in cancer progression. However, the underlying mechanisms of zinc finger proteins in cancer progression vary in different cancer types and even in the same cancer type under different types of stress. Here, we discuss general mechanisms of zinc finger proteins in transcription regulation and summarize recent studies on zinc finger proteins in cancer progression. In this review, we also emphasize the importance of further investigations in elucidating the underlying mechanisms of zinc finger proteins in cancer progression.

  11. EMG finger movement classification based on ANFIS

    NASA Astrophysics Data System (ADS)

    Caesarendra, W.; Tjahjowidodo, T.; Nico, Y.; Wahyudati, S.; Nurhasanah, L.

    2018-04-01

    An increase number of people suffering from stroke has impact to the rapid development of finger hand exoskeleton to enable an automatic physical therapy. Prior to the development of finger exoskeleton, a research topic yet important i.e. machine learning of finger gestures classification is conducted. This paper presents a study on EMG signal classification of 5 finger gestures as a preliminary study toward the finger exoskeleton design and development in Indonesia. The EMG signals of 5 finger gestures were acquired using Myo EMG sensor. The EMG signal features were extracted and reduced using PCA. The ANFIS based learning is used to classify reduced features of 5 finger gestures. The result shows that the classification of finger gestures is less than the classification of 7 hand gestures.

  12. Real time relationship between individual finger force and grip exertion on distal phalanges in linear force following tasks.

    PubMed

    Luo, Shi-Jian; Shu, Ge; Gong, Yan

    2018-05-01

    Individual finger force (FF) in a grip task is a vital concern in rehabilitation engineering and precise control of manipulators because disorders in any of the fingers will affect the stability or accuracy of the grip force (GF). To understand the functions of each finger in a dynamic grip exertion task, a GF following experiment with four individual fingers without thumb was designed. This study obtained four individual FFs from the distal phalanges with a cylindrical handle in dynamic GF following tasks. Ten healthy male subjects with similar hand sizes participated in the four-finger linear GF following tasks at different submaximal voluntary contraction (SMVC) levels. The total GF, individual FF, finger force contribution, and following error were subsequently calculated and analyzed. The statistics indicated the following: 1) the accuracy and stability of GF at low %MVC were significantly higher than those at high SMVC; 2) at low SMVC, the ability of the fingers to increase the GF was better than the ability to reduce it, but it was contrary at high SMVC; 3) when the target wave (TW) was changing, all four fingers strongly participated in the force exertion, but the participation of the little finger decreased significantly when TW remained stable; 4) the index finger and ring finger had a complementary relationship and played a vital role in the adjustment and control of GF. The middle finger and little finger had a minor influence on the force control and adjustment. In conclusion, each of the fingers had different functions in a GF following task. These findings can be used in the assessment of finger injury rehabilitation and for algorithms of precise control. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Preliminary Test Results of a Non-Contacting Finger Seal on a Herringbone-Grooved Rotor

    NASA Technical Reports Server (NTRS)

    Proctor, Margaret P.; Delgado, Irebert R.

    2009-01-01

    The baseline non-contacting finger seal is a NASA patented design. The primary difference between it and Gul Aroras design patented by AlliedSignal is that there are no lift pads on the high pressure fingers. The baseline non-contacting finger seal is comprised of a back plate, aft spacer, aft (or low pressure) finger element, forward (or high pressure) finger element, forward spacer, and front plate. The components are held together with 20 flat head screws. A typical seal would have a back plate of approximately the same thickness as the front plate and would be riveted together. The thicker back plate allows use of threaded fasteners so that different finger elements can be tested without having to replace all the individual seal components. The finger elements are essentially washers made of thin sheet stock with multiple curved slots machined around the inner diameter to form the fingers. They are clocked so that the fingers of one cover the slots of the other. The aft finger element fingers have axial extensions or "lift pads" at the seal id that are concentric to the rotor. The fingers act as cantilever beams and flex in response to rotor dynamic motion and radial growth of the rotor due to centrifugal or thermal forces.

  14. Distinct neural control of intrinsic and extrinsic muscles of the hand during single finger pressing.

    PubMed

    Dupan, Sigrid S G; Stegeman, Dick F; Maas, Huub

    2018-06-01

    Single finger force tasks lead to unintended activation of the non-instructed fingers, commonly referred to as enslaving. Both neural and mechanical factors have been associated with this absence of finger individuality. This study investigates the amplitude modulation of both intrinsic and extrinsic finger muscles during single finger isometric force tasks. Twelve participants performed single finger flexion presses at 20% of maximum voluntary contraction, while simultaneously the electromyographic activity of several intrinsic and extrinsic muscles associated with all four fingers was recorded using 8 electrode pairs in the hand and two 30-electrode grids on the lower arm. The forces exerted by each of the fingers, in both flexion and extension direction, were recorded with individual force sensors. This study shows distinct activation patterns in intrinsic and extrinsic hand muscles. Intrinsic muscles exhibited individuation, where the agonistic and antagonistic muscles associated with the instructed fingers showed the highest activation. This activation in both agonistic and antagonistic muscles appears to facilitate finger stabilisation during the isometric force task. Extrinsic muscles show an activation independent from instructed finger in both agonistic and antagonistic muscles, which appears to be associated with stabilisation of the wrist, with an additional finger-dependent modulation only present in the agonistic extrinsic muscles. These results indicate distinct muscle patterns in intrinsic and extrinsic hand muscles during single finger isometric force pressing. We conclude that the finger specific activation of intrinsic muscles is not sufficient to fully counteract enslaving caused by the broad activation of the extrinsic muscles. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Robotic hand and fingers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salisbury, Curt Michael; Dullea, Kevin J.

    Technologies pertaining to a robotic hand are described herein. The robotic hand includes one or more fingers releasably attached to a robotic hand frame. The fingers can abduct and adduct as well as flex and tense. The fingers are releasably attached to the frame by magnets that allow for the fingers to detach from the frame when excess force is applied to the fingers.

  16. New Finger Biometric Method Using Near Infrared Imaging

    PubMed Central

    Lee, Eui Chul; Jung, Hyunwoo; Kim, Daeyeoul

    2011-01-01

    In this paper, we propose a new finger biometric method. Infrared finger images are first captured, and then feature extraction is performed using a modified Gaussian high-pass filter through binarization, local binary pattern (LBP), and local derivative pattern (LDP) methods. Infrared finger images include the multimodal features of finger veins and finger geometries. Instead of extracting each feature using different methods, the modified Gaussian high-pass filter is fully convolved. Therefore, the extracted binary patterns of finger images include the multimodal features of veins and finger geometries. Experimental results show that the proposed method has an error rate of 0.13%. PMID:22163741

  17. Sliding Window-Based Region of Interest Extraction for Finger Vein Images

    PubMed Central

    Yang, Lu; Yang, Gongping; Yin, Yilong; Xiao, Rongyang

    2013-01-01

    Region of Interest (ROI) extraction is a crucial step in an automatic finger vein recognition system. The aim of ROI extraction is to decide which part of the image is suitable for finger vein feature extraction. This paper proposes a finger vein ROI extraction method which is robust to finger displacement and rotation. First, we determine the middle line of the finger, which will be used to correct the image skew. Then, a sliding window is used to detect the phalangeal joints and further to ascertain the height of ROI. Last, for the corrective image with certain height, we will obtain the ROI by using the internal tangents of finger edges as the left and right boundary. The experimental results show that the proposed method can extract ROI more accurately and effectively compared with other methods, and thus improve the performance of finger vein identification system. Besides, to acquire the high quality finger vein image during the capture process, we propose eight criteria for finger vein capture from different aspects and these criteria should be helpful to some extent for finger vein capture. PMID:23507824

  18. Robot-Assisted Guitar Hero for Finger Rehabilitation after Stroke

    PubMed Central

    Taheri, Hossein; Rowe, Justin B.; Gardner, David; Chan, Vicky; Reinkensmeyer, David J.; Wolbrecht, Eric T.

    2014-01-01

    This paper describes the design and testing of a robotic device for finger therapy after stroke: FINGER (Finger Individuating Grasp Exercise Robot). FINGER makes use of stacked single degree-of-freedom mechanisms to assist subjects in moving individual fingers in a naturalistic grasping pattern through much of their full range of motion. The device has a high bandwidth of control (−3dB at approximately 8 Hz) and is backdriveable. These characteristics make it capable of assisting in grasping tasks that require precise timing. We therefore used FINGER to assist individuals with a stroke (n = 8) and without impairment (n = 4) in playing a game similar to Guitar Hero©. The subjects attempted to move their fingers to target positions at times specified by notes that were graphically streamed to popular music. We show here that by automatically adjusting the robot gains, it is possible to use FINGER to modulate the subject’s success rate at the game, across a range of impairment levels. Modulating success rates did not alter the stroke subject’s effort, although the unimpaired subjects exerted more force when they were made less successful. We also present a novel measure of finger individuation that can be assessed as individuals play Guitar Hero with FINGER. The results demonstrate the ability of FINGER to provide controlled levels of assistance during an engaging computer game, and to quantify finger individuation after stroke. PMID:23366783

  19. Radiation safety education reduces the incidence of adult fingers on neonatal chest radiographs.

    PubMed

    Sahota, N; Burbridge, B E; Duncan, M D

    2014-06-01

    A previous audit revealed a high frequency of adult fingers visualised on neonatal intensive care unit (NICU) chest radiographs-representing an example of inappropriate occupational radiation exposure. Radiation safety education was provided to staff and we hypothesised that the education would reduce the frequency of adult fingers visualised on NICU chest radiographs. Two cross-sectional samples taken before and after the administration of the education were compared. We examined fingers visualised directly in the beam, fingers in the direct beam but eliminated by technologists editing the image, and fingers under the cones of the portable x-ray machine. There was a 46.2% reduction in fingers directly in the beam, 50.0% reduction in fingers directly in the beam but cropped out, and 68.4% reduction in fingers in the coned area. There was a 57.1% overall reduction in adult fingers visualised, which was statistically significant (Z value - 7.48, P < 0.0001). This study supports radiation safety education in minimising inappropriate occupational radiation exposure.

  20. Tendon Driven Finger Actuation System

    NASA Technical Reports Server (NTRS)

    Ihrke, Chris A. (Inventor); Reich, David M. (Inventor); Bridgwater, Lyndon (Inventor); Linn, Douglas Martin (Inventor); Askew, Scott R. (Inventor); Diftler, Myron A. (Inventor); Platt, Robert (Inventor); Hargrave, Brian (Inventor); Valvo, Michael C. (Inventor); Abdallah, Muhammad E. (Inventor); hide

    2013-01-01

    A humanoid robot includes a robotic hand having at least one finger. An actuation system for the robotic finger includes an actuator assembly which is supported by the robot and is spaced apart from the finger. A tendon extends from the actuator assembly to the at least one finger and ends in a tendon terminator. The actuator assembly is operable to actuate the tendon to move the tendon terminator and, thus, the finger.

  1. Optimization for Guitar Fingering on Single Notes

    NASA Astrophysics Data System (ADS)

    Itoh, Masaru; Hayashida, Takumi

    This paper presents an optimization method for guitar fingering. The fingering is to determine a unique combination of string, fret and finger corresponding to the note. The method aims to generate the best fingering pattern for guitar robots rather than beginners. Furthermore, it can be applied to any musical score on single notes. A fingering action can be decomposed into three motions, that is, a motion of press string, release string and move fretting hand. The cost for moving the hand is estimated on the basis of Manhattan distance which is the sum of distances along fret and string directions. The objective is to minimize the total fingering costs, subject to fret, string and finger constraints. As a sequence of notes on the score forms a line on time series, the optimization for guitar fingering can be resolved into a multistage decision problem. Dynamic programming is exceedingly effective to solve such a problem. A level concept is introduced into rendering states so as to make multiple DP solutions lead a unique one among the DP backward processes. For example, if two fingerings have the same value of cost at different states on a stage, then the low position would be taken precedence over the high position, and the index finger would be over the middle finger.

  2. Does finger training increase young children's numerical performance?

    PubMed

    Gracia-Bafalluy, Maria; Noël, Marie-Pascale

    2008-04-01

    Butterworth (1999) suggested that fingers are important in representing numerosities. Furthermore, scores on a finger gnosis test are a better predictor of numerical performance up to 3 years later than intellectual measures (Marinthe et al., 2001; Noël, 2005). We hypothesised that training in finger differentiation would increase finger gnosis and might also improve numerical performance. Accordingly, 47 first-grade children were selected and divided into 3 groups: children with poor finger gnosis who followed the finger-differentiation training programme (G1), a control-intervention who were trained in story comprehension (G2), and a group with high finger gnosis scores who just continued with normal school lessons (G3). The finger training consisted of 2 weekly sessions of half an hour each, for 8 weeks. Before the training period, children in G3 performed better in finger gnosis and enumeration than children in the two other groups. After the training period this pattern remained for the children in G2 and G3, but the children in G1 were significantly better than those in G2 at finger gnosis, representation of numerosities with fingers, and quantification tasks; they also tended to be better at the processing of Arabic digits. These results indicate that improving finger gnosis in young children is possible and that it can provide a useful support to learning mathematics. Such an approach could be particularly appropriate for children with a developmental Gerstmann syndrome. Theoretically, these results are important because they suggest a functional link between finger gnosis and number skills.

  3. ZifBASE: a database of zinc finger proteins and associated resources.

    PubMed

    Jayakanthan, Mannu; Muthukumaran, Jayaraman; Chandrasekar, Sanniyasi; Chawla, Konika; Punetha, Ankita; Sundar, Durai

    2009-09-09

    Information on the occurrence of zinc finger protein motifs in genomes is crucial to the developing field of molecular genome engineering. The knowledge of their target DNA-binding sequences is vital to develop chimeric proteins for targeted genome engineering and site-specific gene correction. There is a need to develop a computational resource of zinc finger proteins (ZFP) to identify the potential binding sites and its location, which reduce the time of in vivo task, and overcome the difficulties in selecting the specific type of zinc finger protein and the target site in the DNA sequence. ZifBASE provides an extensive collection of various natural and engineered ZFP. It uses standard names and a genetic and structural classification scheme to present data retrieved from UniProtKB, GenBank, Protein Data Bank, ModBase, Protein Model Portal and the literature. It also incorporates specialized features of ZFP including finger sequences and positions, number of fingers, physiochemical properties, classes, framework, PubMed citations with links to experimental structures (PDB, if available) and modeled structures of natural zinc finger proteins. ZifBASE provides information on zinc finger proteins (both natural and engineered ones), the number of finger units in each of the zinc finger proteins (with multiple fingers), the synergy between the adjacent fingers and their positions. Additionally, it gives the individual finger sequence and their target DNA site to which it binds for better and clear understanding on the interactions of adjacent fingers. The current version of ZifBASE contains 139 entries of which 89 are engineered ZFPs, containing 3-7F totaling to 296 fingers. There are 50 natural zinc finger protein entries ranging from 2-13F, totaling to 307 fingers. It has sequences and structures from literature, Protein Data Bank, ModBase and Protein Model Portal. The interface is cross linked to other public databases like UniprotKB, PDB, ModBase and Protein Model Portal and PubMed for making it more informative. A database is established to maintain the information of the sequence features, including the class, framework, number of fingers, residues, position, recognition site and physio-chemical properties (molecular weight, isoelectric point) of both natural and engineered zinc finger proteins and dissociation constant of few. ZifBASE can provide more effective and efficient way of accessing the zinc finger protein sequences and their target binding sites with the links to their three-dimensional structures. All the data and functions are available at the advanced web-based search interface http://web.iitd.ac.in/~sundar/zifbase.

  4. Mesofluidic controlled robotic or prosthetic finger

    DOEpatents

    Lind, Randall F; Jansen, John F; Love, Lonnie J

    2013-11-19

    A mesofluidic powered robotic and/or prosthetic finger joint includes a first finger section having at least one mesofluidic actuator in fluid communication with a first actuator, a second mesofluidic actuator in fluid communication with a second actuator and a second prosthetic finger section pivotally connected to the first finger section by a joint pivot, wherein the first actuator pivotally cooperates with the second finger to provide a first mechanical advantage relative to the joint point and wherein the second actuator pivotally cooperates with the second finger section to provide a second mechanical advantage relative to the joint point.

  5. Cradle and pressure grippers

    DOEpatents

    Muniak, John E.

    2001-01-01

    A gripper that is designed to incorporate the functions of gripping, supporting and pressure tongs into one device. The gripper has two opposing finger sections with interlocking fingers that incline and taper to form a wedge. The interlocking fingers are vertically off-set so that the opposing finger sections may close together allowing the inclined, tapered tips of the fingers to extend beyond the plane defined by the opposing finger section's engagement surface. The range of motion defined by the interlocking relationship of the finger sections allows the gripper to grab, lift and support objects of varying size and shape. The gripper has one stationary and one moveable finger section. Power is provided to the moveable finger section by an actuating device enabling the gripper to close around an object to be lifted. A lifting bail is attached to the gripper and is supported by a crane that provides vertical lift.

  6. Multimodal biometric method that combines veins, prints, and shape of a finger

    NASA Astrophysics Data System (ADS)

    Kang, Byung Jun; Park, Kang Ryoung; Yoo, Jang-Hee; Kim, Jeong Nyeo

    2011-01-01

    Multimodal biometrics provides high recognition accuracy and population coverage by using various biometric features. A single finger contains finger veins, fingerprints, and finger geometry features; by using multimodal biometrics, information on these multiple features can be simultaneously obtained in a short time and their fusion can outperform the use of a single feature. This paper proposes a new finger recognition method based on the score-level fusion of finger veins, fingerprints, and finger geometry features. This research is novel in the following four ways. First, the performances of the finger-vein and fingerprint recognition are improved by using a method based on a local derivative pattern. Second, the accuracy of the finger geometry recognition is greatly increased by combining a Fourier descriptor with principal component analysis. Third, a fuzzy score normalization method is introduced; its performance is better than the conventional Z-score normalization method. Fourth, finger-vein, fingerprint, and finger geometry recognitions are combined by using three support vector machines and a weighted SUM rule. Experimental results showed that the equal error rate of the proposed method was 0.254%, which was lower than those of the other methods.

  7. Effects of Finger Counting on Numerical Development – The Opposing Views of Neurocognition and Mathematics Education

    PubMed Central

    Moeller, Korbinian; Martignon, Laura; Wessolowski, Silvia; Engel, Joachim; Nuerk, Hans-Christoph

    2011-01-01

    Children typically learn basic numerical and arithmetic principles using finger-based representations. However, whether or not reliance on finger-based representations is beneficial or detrimental is the subject of an ongoing debate between researchers in neurocognition and mathematics education. From the neurocognitive perspective, finger counting provides multisensory input, which conveys both cardinal and ordinal aspects of numbers. Recent data indicate that children with good finger-based numerical representations show better arithmetic skills and that training finger gnosis, or “finger sense,” enhances mathematical skills. Therefore neurocognitive researchers conclude that elaborate finger-based numerical representations are beneficial for later numerical development. However, research in mathematics education recommends fostering mentally based numerical representations so as to induce children to abandon finger counting. More precisely, mathematics education recommends first using finger counting, then concrete structured representations and, finally, mental representations of numbers to perform numerical operations. Taken together, these results reveal an important debate between neurocognitive and mathematics education research concerning the benefits and detriments of finger-based strategies for numerical development. In the present review, the rationale of both lines of evidence will be discussed. PMID:22144969

  8. Topographic generalization of tactile perceptual learning.

    PubMed

    Harrar, Vanessa; Spence, Charles; Makin, Tamar R

    2014-02-01

    Perceptual learning can improve our sensory abilities. Understanding its underlying mechanisms, in particular, when perceptual learning generalizes, has become a focus of research and controversy. Specifically, there is little consensus regarding the extent to which tactile perceptual learning generalizes across fingers. We measured tactile orientation discrimination abilities on 4 fingers (index and middle fingers of both hands), using psychophysical measures, before and after 4 training sessions on 1 finger. Given the somatotopic organization of the hand representation in the somatosensory cortex, the topography of the cortical areas underlying tactile perceptual learning can be inferred from the pattern of generalization across fingers; only fingers sharing cortical representation with the trained finger ought to improve with it. Following training, performance improved not only for the trained finger but also for its adjacent and homologous fingers. Although these fingers were not exposed to training, they nevertheless demonstrated similar levels of learning as the trained finger. Conversely, the performance of the finger that was neither adjacent nor homologous to the trained finger was unaffected by training, despite the fact that our procedure was designed to enhance generalization, as described in recent visual perceptual learning research. This pattern of improved performance is compatible with previous reports of neuronal receptive fields (RFs) in the primary somatosensory cortex (SI) spanning adjacent and homologous digits. We conclude that perceptual learning rooted in low-level cortex can still generalize, and suggest potential applications for the neurorehabilitation of syndromes associated with maladaptive plasticity in SI. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  9. Extrinsic versus intrinsic hand muscle dominance in finger flexion.

    PubMed

    Al-Sukaini, A; Singh, H P; Dias, J J

    2016-05-01

    This study aims to identify the patterns of dominance of extrinsic or intrinsic muscles in finger flexion during initiation of finger curl and mid-finger flexion. We recorded 82 hands of healthy individuals (18-74 years) while flexing their fingers and tracked the finger joint angles of the little finger using video motion tracking. A total of 57 hands (69.5%) were classified as extrinsic dominant, where the finger flexion was initiated and maintained at proximal interphalangeal and distal interphalangeal joints. A total of 25 (30.5%) were classified as intrinsic dominant, where the finger flexion was initiated and maintained at the metacarpophalangeal joint. The distribution of age, sex, dominance, handedness and body mass index was similar in the two groups. This knowledge may allow clinicians to develop more efficient rehabilitation regimes, since intrinsic dominant individuals would not initiate extrinsic muscle contraction till later in finger flexion, and might therefore be allowed limited early active motion. For extrinsic dominant individuals, by contrast, initial contraction of extrinsic muscles would place increased stress on the tendon repair site if early motion were permitted. © The Author(s) 2016.

  10. Evaluation of nutraceutical and antinutritional properties in barnyard and finger millet varieties grown in Himalayan region.

    PubMed

    Panwar, Priyankar; Dubey, Ashutosh; Verma, A K

    2016-06-01

    Five elite varieties of barnyard (Echinochloa frumentacea) and finger (Eleusine coracana) growing at northwestern Himalaya were investigated for nutraceutical and antinutritional properties. Barnyard millet contained higher amount of crude fiber, total dietary fiber, tryptophan content, total carotenoids, α-tocopherol compared to the finger millet whereas the finger millet contains higher amount of methionine and ascorbic acid as compared to the barnyard millet. The secondary metabolites of biological functions were analyzed and found that barnyard millet contained the higher amount of polyphenols, tannins and ortho-dihydroxy phenol content compared to finger millet. Among antinutitional compounds barnyard millet contained lower phytic acid content compare to finger millet whereas no significant difference in trypsin inhibition activity of barnyard millet and finger millet varieties were found. Barnyard millet contained higher acid phosphatase, α-galactosidase and α-amylase inhibitor activity compared to finger millet. Finger millet seeds contained about 10-13 folds higher calcium content and double amount of manganese content in comparison to barnyard millet seeds. Present study suggests that barnyard millet varieties studied under present investigation were found nutritionally superior compared to finger millet varieties.

  11. Effects of endothelium-derived nitric oxide on skin and digital blood flow in humans.

    PubMed

    Coffman, J D

    1994-12-01

    The effects of NG-monomethyl-L-arginine (L-NMMA) on total finger and forearm, and dorsal finger and forearm skin, blood flows were studied in the basal state and during reflex sympathetic vasoconstriction in normal subjects. Total flows were measured by venous occlusion plethysmography and skin flows by laser-Doppler flowmetry (LDF). L-NMMA in doses of 2, 4, and 8 microM/min given by constant infusion via a brachial artery catheter significantly decreased finger blood flow, forearm blood flow, and vascular conductances. At 8 microM/min, total finger blood flow decreased 38.4% and forearm blood flow decreased 24.8%. Dorsal finger and forearm skin LDF were also significantly decreased (25 and 37% at 8 microM/min). Body cooling significantly decreased finger blood flow (73.6%), vascular conductance, and finger LDF (59.7%). L-NMMA had no effect on total finger blood flow or dorsal finger LDF during body cooling. Nitric oxide or related compounds contribute to the basal dilator tone of the dorsal finger and forearm skin but not during reflex sympathetic vasoconstriction.

  12. Multi-fingered robotic hand

    NASA Technical Reports Server (NTRS)

    Ruoff, Carl F. (Inventor); Salisbury, Kenneth, Jr. (Inventor)

    1990-01-01

    A robotic hand is presented having a plurality of fingers, each having a plurality of joints pivotally connected one to the other. Actuators are connected at one end to an actuating and control mechanism mounted remotely from the hand and at the other end to the joints of the fingers for manipulating the fingers and passing externally of the robot manipulating arm in between the hand and the actuating and control mechanism. The fingers include pulleys to route the actuators within the fingers. Cable tension sensing structure mounted on a portion of the hand are disclosed, as is covering of the tip of each finger with a resilient and pliable friction enhancing surface.

  13. Compliant finger sensor for sensorimotor studies in MEG and MR environment

    NASA Astrophysics Data System (ADS)

    Li, Y.; Yong, X.; Cheung, T. P. L.; Menon, C.

    2016-07-01

    Magnetoencephalography (MEG) and functional magnetic resonance imaging (fMRI) are widely used for functional brain imaging. The correlations between the sensorimotor functions of the hand and brain activities have been investigated in MEG/fMRI studies. Currently, limited information can be drawn from these studies due to the limitations of existing motion sensors that are used to detect hand movements. One major challenge in designing these motion sensors is to limit the signal interference between the motion sensors and the MEG/fMRI. In this work, a novel finger motion sensor, which contains low-ferromagnetic and non-conductive materials, is introduced. The finger sensor consists of four air-filled chambers. When compressed by finger(s), the pressure change in the chambers can be detected by the electronics of the finger sensor. Our study has validated that the interference between the finger sensor and an MEG is negligible. Also, by applying a support vector machine algorithm to the data obtained from the finger sensor, at least 11 finger patterns can be discriminated. Comparing to the use of traditional electromyography (EMG) in detecting finger motion, our proposed finger motion sensor is not only MEG/fMRI compatible, it is also easy to use. As the signals acquired from the sensor have a higher SNR than that of the EMG, no complex algorithms are required to detect different finger movement patterns. Future studies can utilize this motion sensor to investigate brain activations during different finger motions and correlate the activations with the sensory and motor functions respectively.

  14. Individual Finger Control of the Modular Prosthetic Limb using High-Density Electrocorticography in a Human Subject

    PubMed Central

    Fifer, Matthew S.; Johannes, Matthew S.; Katyal, Kapil D.; Para, Matthew P.; Armiger, Robert; Anderson, William S.; Thakor, Nitish V.; Wester, Brock A.; Crone, Nathan E.

    2016-01-01

    Objective We used native sensorimotor representations of fingers in a brain-machine interface to achieve immediate online control of individual prosthetic fingers. Approach Using high gamma responses recorded with a high-density ECoG array, we rapidly mapped the functional anatomy of cued finger movements. We used these cortical maps to select ECoG electrodes for a hierarchical linear discriminant analysis classification scheme to predict: 1) if any finger was moving, and, if so, 2) which digit was moving. To account for sensory feedback, we also mapped the spatiotemporal activation elicited by vibrotactile stimulation. Finally, we used this prediction framework to provide immediate online control over individual fingers of the Johns Hopkins University Applied Physics Laboratory (JHU/APL) Modular Prosthetic Limb (MPL). Main Results The balanced classification accuracy for detection of movements during the online control session was 92% (chance: 50%). At the onset of movement, finger classification was 76% (chance: 20%), and 88% (chance: 25%) if the pinky and ring finger movements were coupled. Balanced accuracy of fully flexing the cued finger was 64%, and 77% had we combined pinky and ring commands. Offline decoding yielded a peak finger decoding accuracy of 96.5% (chance: 20%) when using an optimized selection of electrodes. Offline analysis demonstrated significant finger-specific activations throughout sensorimotor cortex. Activations either prior to movement onset or during sensory feedback led to discriminable finger control. Significance Our results demonstrate the ability of ECoG-based BMIs to leverage the native functional anatomy of sensorimotor cortical populations to immediately control individual finger movements in real time. PMID:26863276

  15. Individual finger control of a modular prosthetic limb using high-density electrocorticography in a human subject

    NASA Astrophysics Data System (ADS)

    Hotson, Guy; McMullen, David P.; Fifer, Matthew S.; Johannes, Matthew S.; Katyal, Kapil D.; Para, Matthew P.; Armiger, Robert; Anderson, William S.; Thakor, Nitish V.; Wester, Brock A.; Crone, Nathan E.

    2016-04-01

    Objective. We used native sensorimotor representations of fingers in a brain-machine interface (BMI) to achieve immediate online control of individual prosthetic fingers. Approach. Using high gamma responses recorded with a high-density electrocorticography (ECoG) array, we rapidly mapped the functional anatomy of cued finger movements. We used these cortical maps to select ECoG electrodes for a hierarchical linear discriminant analysis classification scheme to predict: (1) if any finger was moving, and, if so, (2) which digit was moving. To account for sensory feedback, we also mapped the spatiotemporal activation elicited by vibrotactile stimulation. Finally, we used this prediction framework to provide immediate online control over individual fingers of the Johns Hopkins University Applied Physics Laboratory modular prosthetic limb. Main results. The balanced classification accuracy for detection of movements during the online control session was 92% (chance: 50%). At the onset of movement, finger classification was 76% (chance: 20%), and 88% (chance: 25%) if the pinky and ring finger movements were coupled. Balanced accuracy of fully flexing the cued finger was 64%, and 77% had we combined pinky and ring commands. Offline decoding yielded a peak finger decoding accuracy of 96.5% (chance: 20%) when using an optimized selection of electrodes. Offline analysis demonstrated significant finger-specific activations throughout sensorimotor cortex. Activations either prior to movement onset or during sensory feedback led to discriminable finger control. Significance. Our results demonstrate the ability of ECoG-based BMIs to leverage the native functional anatomy of sensorimotor cortical populations to immediately control individual finger movements in real time.

  16. The multi-zinc finger protein ZNF217 contacts DNA through a two-finger domain.

    PubMed

    Nunez, Noelia; Clifton, Molly M K; Funnell, Alister P W; Artuz, Crisbel; Hallal, Samantha; Quinlan, Kate G R; Font, Josep; Vandevenne, Marylène; Setiyaputra, Surya; Pearson, Richard C M; Mackay, Joel P; Crossley, Merlin

    2011-11-04

    Classical C2H2 zinc finger proteins are among the most abundant transcription factors found in eukaryotes, and the mechanisms through which they recognize their target genes have been extensively investigated. In general, a tandem array of three fingers separated by characteristic TGERP links is required for sequence-specific DNA recognition. Nevertheless, a significant number of zinc finger proteins do not contain a hallmark three-finger array of this type, raising the question of whether and how they contact DNA. We have examined the multi-finger protein ZNF217, which contains eight classical zinc fingers. ZNF217 is implicated as an oncogene and in repressing the E-cadherin gene. We show that two of its zinc fingers, 6 and 7, can mediate contacts with DNA. We examine its putative recognition site in the E-cadherin promoter and demonstrate that this is a suboptimal site. NMR analysis and mutagenesis is used to define the DNA binding surface of ZNF217, and we examine the specificity of the DNA binding activity using fluorescence anisotropy titrations. Finally, sequence analysis reveals that a variety of multi-finger proteins also contain two-finger units, and our data support the idea that these may constitute a distinct subclass of DNA recognition motif.

  17. The Multi-zinc Finger Protein ZNF217 Contacts DNA through a Two-finger Domain*

    PubMed Central

    Nunez, Noelia; Clifton, Molly M. K.; Funnell, Alister P. W.; Artuz, Crisbel; Hallal, Samantha; Quinlan, Kate G. R.; Font, Josep; Vandevenne, Marylène; Setiyaputra, Surya; Pearson, Richard C. M.; Mackay, Joel P.; Crossley, Merlin

    2011-01-01

    Classical C2H2 zinc finger proteins are among the most abundant transcription factors found in eukaryotes, and the mechanisms through which they recognize their target genes have been extensively investigated. In general, a tandem array of three fingers separated by characteristic TGERP links is required for sequence-specific DNA recognition. Nevertheless, a significant number of zinc finger proteins do not contain a hallmark three-finger array of this type, raising the question of whether and how they contact DNA. We have examined the multi-finger protein ZNF217, which contains eight classical zinc fingers. ZNF217 is implicated as an oncogene and in repressing the E-cadherin gene. We show that two of its zinc fingers, 6 and 7, can mediate contacts with DNA. We examine its putative recognition site in the E-cadherin promoter and demonstrate that this is a suboptimal site. NMR analysis and mutagenesis is used to define the DNA binding surface of ZNF217, and we examine the specificity of the DNA binding activity using fluorescence anisotropy titrations. Finally, sequence analysis reveals that a variety of multi-finger proteins also contain two-finger units, and our data support the idea that these may constitute a distinct subclass of DNA recognition motif. PMID:21908891

  18. Trigger Finger (Stenosing Tenosynovitis)

    MedlinePlus

    ... Trigger Finger Find a hand surgeon near you. Videos Trigger Finger Animation Trigger Finger Close Popup Close ... or "in." Also, avoid using media types like "video," "article," and "picture." Tip 4: Your results can ...

  19. Outcomes of Silicone Arthroplasty Stratified by Fingers for the Rheumatoid Metacarpophalangeal Joints

    PubMed Central

    Chung, Kevin C.; Kotsis, Sandra V.; Shaw Wilgis, E. F.; Fox, David A.; Regan, Marian; Kim, H. Myra; Burke, Frank D.

    2015-01-01

    Purpose Previous studies have demonstrated that outcomes for the ulnar digits appear to be worse than the radial digits after silicone metacarpophalangeal joint arthroplasty (SMPA) for the rheumatoid hand. This study examines various components of hand deformities in an effort to understand SMPA outcomes in terms of metacarpophalangeal joint range of motion and alignment. We hypothesize that the ulnar fingers will have less improvement marked by greater ulnar drift, extension lag, and less metacarpophalangeal joint (MCPJ) arc of motion than the radial fingers. Methods 68 surgical patients were recruited from 3 sites in this multi-center international prospective cohort study. All patients had a diagnosis of rheumatoid arthritis, were between the ages of 18–80, and were eligible to undergo SMPA based on measured hand deformities (extensor lag and ulnar drift). Ulnar drift, extension lag, and arc of motion for the MCPJ of each finger were measured at baseline (pre-surgical) and 1-year after SMPA. Results All fingers showed an improvement in ulnar drift from baseline to 1-year after surgery. The smallest improvement was in the index finger (12°) and the largest improvement was in the little finger (30°). Similarly, the largest improvement in extension lag was seen in the little finger (47°) and the smallest improvement was seen in the index finger (21°). In terms of MCPJ arc of motion, all fingers moved to a more extended posture and gained an improved arc of motion, but the biggest improvement was observed in the 2 ulnar fingers and less so in the 2 radial fingers. Conclusions Our hypothesis that the ulnar fingers will have worse outcomes than the radial fingers is not proven by this study. Although past experiences have indicated that it is more difficult to maintain posture for the ring and little fingers after SMPA due to the deforming forces, sufficient correction of the deformities in the ulnar fingers is possible, if attention to adequate bone resection and realigning of the extensor mechanism are carefully performed during the procedure. PMID:19896008

  20. Selective Sensitization of Zinc Finger Protein Oxidation by Reactive Oxygen Species through Arsenic Binding*

    PubMed Central

    Zhou, Xixi; Cooper, Karen L.; Sun, Xi; Liu, Ke J.; Hudson, Laurie G.

    2015-01-01

    Cysteine oxidation induced by reactive oxygen species (ROS) on redox-sensitive targets such as zinc finger proteins plays a critical role in redox signaling and subsequent biological outcomes. We found that arsenic exposure led to oxidation of certain zinc finger proteins based on arsenic interaction with zinc finger motifs. Analysis of zinc finger proteins isolated from arsenic-exposed cells and zinc finger peptides by mass spectrometry demonstrated preferential oxidation of C3H1 and C4 zinc finger configurations. C2H2 zinc finger proteins that do not bind arsenic were not oxidized by arsenic-generated ROS in the cellular environment. The findings suggest that selectivity in arsenic binding to zinc fingers with three or more cysteines defines the target proteins for oxidation by ROS. This represents a novel mechanism of selective protein oxidation and demonstrates how an environmental factor may sensitize certain target proteins for oxidation, thus altering the oxidation profile and redox regulation. PMID:26063799

  1. The influence of intrinsic sympathomimetic activity and beta-1 receptor selectivity on the recovery of finger skin temperature after finger cooling in normotensive subjects.

    PubMed

    Lenders, J W; Salemans, J; de Boo, T; Lemmens, W A; Thien, T; van't Laar, A

    1986-03-01

    A double-blind randomized study was designed to investigate differences in the recovery of finger skin temperature after finger cooling during dosing with placebo or one of four beta-blockers: propranolol, atenolol, pindolol, and acebutolol. In 11 normotensive nonsmoking subjects, finger skin temperature was measured with a thermocouple before and 20 minutes after immersion of one hand in a water bath at 16 degrees C. This finger cooling test caused no significant changes in systemic hemodynamics such as arterial blood pressure, heart rate, and forearm blood flow. The recovery of finger skin temperature during propranolol dosing was better than that during pindolol and atenolol dosing. There were no differences between the recoveries of skin temperature during pindolol, atenolol, and acebutolol dosing. Thus we could demonstrate no favorable effect of intrinsic sympathomimetic activity or beta 1-selectivity on the recovery of finger skin temperature after finger cooling.

  2. Self-locking telescoping manipulator arm

    NASA Technical Reports Server (NTRS)

    Nesmith, M. F. (Inventor)

    1985-01-01

    A telescoping manipulator arm and pivotable finger assembly are disclosed. The telescoping arm assembly includes a generally T-shaped arm having three outwardly extending fingers guided on grooved roller guides to compensate for environmental variations. The pivotable finger assembly includes four pivoting fingers. Arcuate teeth are formed on the ends of the fingers. A rack having teeth on four sides meshes with each one of the fingers. One surface of the rack includes teeth along its entire surface which mesh with teeth of one of the fingers. The teeth at the remote end of the rack engage teeth of a gear wheel. The wheel includes a worm which meshes with a worn drive shaft of the drive motor providing a ninety degree self-locking drive for locking the fingers in a desired position. A similar drive provides a self-locking drive for positioning the telescoping arm.

  3. Determining the bias and variance of a deterministic finger-tracking algorithm.

    PubMed

    Morash, Valerie S; van der Velden, Bas H M

    2016-06-01

    Finger tracking has the potential to expand haptic research and applications, as eye tracking has done in vision research. In research applications, it is desirable to know the bias and variance associated with a finger-tracking method. However, assessing the bias and variance of a deterministic method is not straightforward. Multiple measurements of the same finger position data will not produce different results, implying zero variance. Here, we present a method of assessing deterministic finger-tracking variance and bias through comparison to a non-deterministic measure. A proof-of-concept is presented using a video-based finger-tracking algorithm developed for the specific purpose of tracking participant fingers during a psychological research study. The algorithm uses ridge detection on videos of the participant's hand, and estimates the location of the right index fingertip. The algorithm was evaluated using data from four participants, who explored tactile maps using only their right index finger and all right-hand fingers. The algorithm identified the index fingertip in 99.78 % of one-finger video frames and 97.55 % of five-finger video frames. Although the algorithm produced slightly biased and more dispersed estimates relative to a human coder, these differences (x=0.08 cm, y=0.04 cm) and standard deviations (σ x =0.16 cm, σ y =0.21 cm) were small compared to the size of a fingertip (1.5-2.0 cm). Some example finger-tracking results are provided where corrections are made using the bias and variance estimates.

  4. Finger-specific loss of independent control of movements in musicians with focal dystonia.

    PubMed

    Furuya, S; Altenmüller, E

    2013-09-05

    The loss of independent control of finger movements impairs the dexterous use of the hand. Focal hand dystonia is characterised by abnormal structural and functional changes at the cortical and subcortical regions responsible for individuated finger movements and by the loss of surround inhibition in the finger muscles. However, little is known about the pathophysiological impact of focal dystonia on the independent control of finger movements. Here we addressed this issue by asking pianists with and without focal dystonia to repetitively strike a piano key with one of the four fingers as fast as possible while the remaining digits kept the adjacent keys depressed. Using principal component analysis and cluster analysis to the derived keystroke data, we successfully classified pianists according to the presence or absence of dystonic symptoms with classification rates and cross-validation scores of approximately 90%. This confirmed the effects of focal dystonia on the individuated finger movements. Interestingly, the movement features that contributed to successful classification differed across fingers. Compared to healthy pianists, pianists with an affected index finger were characterised predominantly by stronger keystrokes, whereas pianists with affected middle or ring fingers exhibited abnormal temporal control of the keystrokes, such as slowness and rhythmic inconsistency. The selective alternation of the movement features indicates a finger-specific loss of the independent control of finger movements in focal dystonia of musicians. Copyright © 2013 IBRO. Published by Elsevier Ltd. All rights reserved.

  5. Refining the cross-finger flap: Considerations of flap insetting, aesthetics and donor site morbidity.

    PubMed

    Chong, Chew-Wei; Lin, Cheng-Hung; Lin, Yu-Te; Hsu, Chung-Chen; Chen, Shih-Heng

    2018-04-01

    We described a laterally based cross-finger flap for reconstruction of soft tissue defects in the fingers. This modification enables coverage of volar or dorsal soft tissue defects at the distal, middle or proximal phalanx. From March 2015 to January 2017, a total of 12 patients (13 fingers) underwent soft tissue reconstruction of the fingers with a laterally based cross-finger flap. The flap dimensions ranged from 13 ×7 mm to 43 ×13 mm. Eleven of the 13 flaps survived completely. The two flap failures were attributed to injuries in the donor fingers, rendering the blood supply of the flaps unreliable. All donor sites were closed primarily without the need for skin grafting, negating the problem of donor site morbidity that is associated with skin graft harvesting. The laterally based cross-finger flap is a versatile flap with less donor site morbidity and better aesthetics than a conventional cross-finger flap. We described the design of the flap, as well as the advantages and disadvantages, in doing a laterally based cross-finger flap. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  6. Sensory Feedback Training for Improvement of Finger Perception in Cerebral Palsy

    PubMed Central

    Alves-Pinto, Ana; Aschmann, Simon; Lützow, Ines; Lampe, Renée

    2015-01-01

    Purpose. To develop and to test a feedback training system for improvement of tactile perception and coordination of fingers in children and youth with cerebral palsy. Methods. The fingers of 7 probands with cerebral palsy of different types and severity were stimulated using small vibration motors integrated in the fingers of a hand glove. The vibration motors were connected through a microcontroller to a computer and to a response 5-button keyboard. By pressing an appropriate keyboard button, the proband must indicate in which finger the vibration was felt. The number of incorrect responses and the reaction time were measured for every finger. The perception and coordination of fingers were estimated before and after two-week training using both clinical tests and the measurements. Results. Proper functioning of the developed system in persons with cerebral palsy was confirmed. The tactile sensation of fingers was improved in five of seven subjects after two weeks of training. There was no clear tendency towards improvement of selective use of fingers. Conclusion. The designed feedback system could be used to train tactile perception of fingers in children and youth with cerebral palsy. An extensive study is required to confirm these findings. PMID:26124965

  7. Estimation of Finger Joint Angles Based on Electromechanical Sensing of Wrist Shape.

    PubMed

    Kawaguchi, Junki; Yoshimoto, Shunsuke; Kuroda, Yoshihiro; Oshiro, Osamu

    2017-09-01

    An approach to finger motion capture that places fewer restrictions on the usage environment and actions of the user is an important research topic in biomechanics and human-computer interaction. We proposed a system that electrically detects finger motion from the associated deformation of the wrist and estimates the finger joint angles using multiple regression models. A wrist-mounted sensing device with 16 electrodes detects deformation of the wrist from changes in electrical contact resistance at the skin. In this study, we experimentally investigated the accuracy of finger joint angle estimation, the adequacy of two multiple regression models, and the resolution of the estimation of total finger joint angles. In experiments, both the finger joint angles and the system output voltage were recorded as subjects performed flexion/extension of the fingers. These data were used for calibration using the least-squares method. The system was found to be capable of estimating the total finger joint angle with a root-mean-square error of 29-34 degrees. A multiple regression model with a second-order polynomial basis function was shown to be suitable for the estimation of all total finger joint angles, but not those of the thumb.

  8. Sensory Feedback Training for Improvement of Finger Perception in Cerebral Palsy.

    PubMed

    Blumenstein, Tobias; Alves-Pinto, Ana; Turova, Varvara; Aschmann, Simon; Lützow, Ines; Lampe, Renée

    2015-01-01

    Purpose. To develop and to test a feedback training system for improvement of tactile perception and coordination of fingers in children and youth with cerebral palsy. Methods. The fingers of 7 probands with cerebral palsy of different types and severity were stimulated using small vibration motors integrated in the fingers of a hand glove. The vibration motors were connected through a microcontroller to a computer and to a response 5-button keyboard. By pressing an appropriate keyboard button, the proband must indicate in which finger the vibration was felt. The number of incorrect responses and the reaction time were measured for every finger. The perception and coordination of fingers were estimated before and after two-week training using both clinical tests and the measurements. Results. Proper functioning of the developed system in persons with cerebral palsy was confirmed. The tactile sensation of fingers was improved in five of seven subjects after two weeks of training. There was no clear tendency towards improvement of selective use of fingers. Conclusion. The designed feedback system could be used to train tactile perception of fingers in children and youth with cerebral palsy. An extensive study is required to confirm these findings.

  9. Intercalary non-vascularised toe phalanx transplantation for short finger-type symbrachydactyly.

    PubMed

    Kanauchi, Yumiko; Takahara, Masatoshi; Ogino, Toshihiko; Kashiwa, Hideo; Ishigaki, Daisuke

    2003-12-01

    A two-year-old boy with short finger-type symbrachydactyly involving the index, middle, and ring fingers was treated with intercalary nonvascularised toe phalanx transplantation into the middle finger to obtain stability of the middle finger before syndactyly release. He underwent syndactyly release one year after the transplantation. Two years after the transplantation, the clinical result was satisfactory, although X-ray showed fibrous union between the transplanted phalanx and the host phalanx. Intercalary nonvascularised toe phalanx transplantation is one of the way of stabilising a finger after syndactyly release.

  10. A multiscale approach to simulating the conformational properties of unbound multi-C₂H₂ zinc finger proteins.

    PubMed

    Liu, Lei; Wade, Rebecca C; Heermann, Dieter W

    2015-09-01

    The conformational properties of unbound multi-Cys2 His2 (mC2H2) zinc finger proteins, in which zinc finger domains are connected by flexible linkers, are studied by a multiscale approach. Three methods on different length scales are utilized. First, atomic detail molecular dynamics simulations of one zinc finger and its adjacent flexible linker confirmed that the zinc finger is more rigid than the flexible linker. Second, the end-to-end distance distributions of mC2H2 zinc finger proteins are computed using an efficient atomistic pivoting algorithm, which only takes excluded volume interactions into consideration. The end-to-end distance distribution gradually changes its profile, from left-tailed to right-tailed, as the number of zinc fingers increases. This is explained by using a worm-like chain model. For proteins of a few zinc fingers, an effective bending constraint favors an extended conformation. Only for proteins containing more than nine zinc fingers, is a somewhat compacted conformation preferred. Third, a mesoscale model is modified to study both the local and the global conformational properties of multi-C2H2 zinc finger proteins. Simulations of the CCCTC-binding factor (CTCF), an important mC2H2 zinc finger protein for genome spatial organization, are presented. © 2015 Wiley Periodicals, Inc.

  11. Convolutional Neural Network-Based Finger-Vein Recognition Using NIR Image Sensors

    PubMed Central

    Hong, Hyung Gil; Lee, Min Beom; Park, Kang Ryoung

    2017-01-01

    Conventional finger-vein recognition systems perform recognition based on the finger-vein lines extracted from the input images or image enhancement, and texture feature extraction from the finger-vein images. In these cases, however, the inaccurate detection of finger-vein lines lowers the recognition accuracy. In the case of texture feature extraction, the developer must experimentally decide on a form of the optimal filter for extraction considering the characteristics of the image database. To address this problem, this research proposes a finger-vein recognition method that is robust to various database types and environmental changes based on the convolutional neural network (CNN). In the experiments using the two finger-vein databases constructed in this research and the SDUMLA-HMT finger-vein database, which is an open database, the method proposed in this research showed a better performance compared to the conventional methods. PMID:28587269

  12. Convolutional Neural Network-Based Finger-Vein Recognition Using NIR Image Sensors.

    PubMed

    Hong, Hyung Gil; Lee, Min Beom; Park, Kang Ryoung

    2017-06-06

    Conventional finger-vein recognition systems perform recognition based on the finger-vein lines extracted from the input images or image enhancement, and texture feature extraction from the finger-vein images. In these cases, however, the inaccurate detection of finger-vein lines lowers the recognition accuracy. In the case of texture feature extraction, the developer must experimentally decide on a form of the optimal filter for extraction considering the characteristics of the image database. To address this problem, this research proposes a finger-vein recognition method that is robust to various database types and environmental changes based on the convolutional neural network (CNN). In the experiments using the two finger-vein databases constructed in this research and the SDUMLA-HMT finger-vein database, which is an open database, the method proposed in this research showed a better performance compared to the conventional methods.

  13. Finger-vein and fingerprint recognition based on a feature-level fusion method

    NASA Astrophysics Data System (ADS)

    Yang, Jinfeng; Hong, Bofeng

    2013-07-01

    Multimodal biometrics based on the finger identification is a hot topic in recent years. In this paper, a novel fingerprint-vein based biometric method is proposed to improve the reliability and accuracy of the finger recognition system. First, the second order steerable filters are used here to enhance and extract the minutiae features of the fingerprint (FP) and finger-vein (FV). Second, the texture features of fingerprint and finger-vein are extracted by a bank of Gabor filter. Third, a new triangle-region fusion method is proposed to integrate all the fingerprint and finger-vein features in feature-level. Thus, the fusion features contain both the finger texture-information and the minutiae triangular geometry structure. Finally, experimental results performed on the self-constructed finger-vein and fingerprint databases are shown that the proposed method is reliable and precise in personal identification.

  14. Analysis of prosody in finger braille using electromyography.

    PubMed

    Miyagi, Manabi; Nishida, Masafumi; Horiuchi, Yasuo; Ichikawa, Akira

    2006-01-01

    Finger braille is one of the communication methods for the deaf blind. The interpreter types braille codes on the fingers of deaf blind. Finger braille seems to be the most suitable medium for real-time communication by its speed and accuracy of transmitting characters. We hypothesize that the prosody information exists in the time structure and strength of finger braille typing. Prosody is the paralinguistic information that has functions to transmit the sentence structure, prominence, emotions and other form of information in real time communication. In this study, we measured the surface electromyography (sEMG) of finger movement to analyze the typing strength of finger braille. We found that the typing strength increases at the beginning of a phrase and a prominent phrase. The result shows the possibility that the prosody in the typing strength of finger braille can be applied to create an interpreter system for the deafblind.

  15. The Role of Vision in the Development of Finger-Number Interactions: Finger-Counting and Finger-Montring in Blind Children

    ERIC Educational Resources Information Center

    Crollen, Virginie; Mahe, Rachel; Collignon, Olivier; Seron, Xavier

    2011-01-01

    Previous research has suggested that the use of the fingers may play a functional role in the development of a mature counting system. However, the role of developmental vision in the elaboration of a finger numeral representation remains unexplored. In the current study, 14 congenitally blind children and 14 matched sighted controls undertook…

  16. Modulated cortical control of individual fingers in experienced musicians: an EEG study. Electroencephalographic study.

    PubMed

    Slobounov, S; Chiang, H; Johnston, J; Ray, W

    2002-12-01

    The present research was designed to address the nature of interdependency between fingers during force production tasks in subjects with varying experience in performing independent finger manipulation. Specifically, behavioral and electroencephalographic (EEG) measures associated with controllability of the most enslaved (ring) and the least enslaved (index) fingers was examined in musicians and non-musicians. Six piano players and 6 age-matched control subjects performed a series of isometric force production tasks with the index and ring fingers. Subjects produced 3 different force levels with either their index or ring fingers. We measured the isometric force output produced by all 4 fingers (index, ring, middle and little), including both ramp and static phases of force production. We applied time-domain averaging of EEG single trials in order to extract 4 components of the movement-related cortical potentials (MRCP) preceding and accompanying force responses. Three behavioral findings were observed. First, musicians were more accurate than non-musicians at reaching the desired force level. Second, musicians showed less enslaving as compared to non-musicians. And third, the amount of enslaving increased with the increment of nominal force levels regardless of whether the index or ring finger was used as the master finger. In terms of EEG measures, we found differences between tasks performed with the index and ring fingers in non-musicians. For musicians, we found larger MRCP amplitudes at most electrode sites for the ring finger. Our data extends previous enslaving research and suggest an important role for previous experience in terms of the independent use of the fingers. Given that a variety of previous work has shown finger independence to be reflected in cortical representation in the brain and our findings of MRCP amplitude associated with greater independence of fingers in musicians, this suggests that what has been considered to be stable constraints in terms of finger movements can be modulated by experience. This work supports the idea that experience is associated with changes in behavioral and EEG correlates of task performance and may have clinical implications in disorders such as stroke or focal hand dystonia. Practice-related procedures offer useful approaches to rehabilitation strategies.

  17. Adaptive increase in force variance during fatigue in tasks with low redundancy.

    PubMed

    Singh, Tarkeshwar; S K M, Varadhan; Zatsiorsky, Vladimir M; Latash, Mark L

    2010-11-26

    We tested a hypothesis that fatigue of an element (a finger) leads to an adaptive neural strategy that involves an increase in force variability in the other finger(s) and an increase in co-variation of commands to fingers to keep total force variability relatively unchanged. We tested this hypothesis using a system with small redundancy (two fingers) and a marginally redundant system (with an additional constraint related to the total moment of force produced by the fingers, unstable condition). The subjects performed isometric accurate rhythmic force production tasks by the index (I) finger and two fingers (I and middle, M) pressing together before and after a fatiguing exercise by the I finger. Fatigue led to a large increase in force variance in the I-finger task and a smaller increase in the IM-task. We quantified two components of variance in the space of hypothetical commands to fingers, finger modes. Under both stable and unstable conditions, there was a large increase in the variance component that did not affect total force and a much smaller increase in the component that did. This resulted in an increase in an index of the force-stabilizing synergy. These results indicate that marginal redundancy is sufficient to allow the central nervous system to use adaptive increase in variability to shield important variables from effects of fatigue. We offer an interpretation of these results based on a recent development of the equilibrium-point hypothesis known as the referent configuration hypothesis. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  18. Finger agnosia and cognitive deficits in patients with Alzheimer's disease.

    PubMed

    Davis, Andrew S; Trotter, Jeffrey S; Hertza, Jeremy; Bell, Christopher D; Dean, Raymond S

    2012-01-01

    The purpose of this study was to examine the presence of finger agnosia in patients with Alzheimer's disease (AD) and to determine if level of finger agnosia was related to cognitive impairment. Finger agnosia is a sensitive measure of cerebral impairment and is associated with neurofunctional areas implicated in AD. Using a standardized and norm-referenced approach, results indicated that patients with AD evidenced significantly decreased performance on tests of bilateral finger agnosia compared with healthy age-matched controls. Finger agnosia was predictive of cognitive dysfunction on four of seven domains, including: Crystallized Language, Fluid Processing, Associative Learning, and Processing Speed. Results suggest that measures of finger agnosia, a short and simple test, may be useful in the early detection of AD.

  19. Robust finger vein ROI localization based on flexible segmentation.

    PubMed

    Lu, Yu; Xie, Shan Juan; Yoon, Sook; Yang, Jucheng; Park, Dong Sun

    2013-10-24

    Finger veins have been proved to be an effective biometric for personal identification in the recent years. However, finger vein images are easily affected by influences such as image translation, orientation, scale, scattering, finger structure, complicated background, uneven illumination, and collection posture. All these factors may contribute to inaccurate region of interest (ROI) definition, and so degrade the performance of finger vein identification system. To improve this problem, in this paper, we propose a finger vein ROI localization method that has high effectiveness and robustness against the above factors. The proposed method consists of a set of steps to localize ROIs accurately, namely segmentation, orientation correction, and ROI detection. Accurate finger region segmentation and correct calculated orientation can support each other to produce higher accuracy in localizing ROIs. Extensive experiments have been performed on the finger vein image database, MMCBNU_6000, to verify the robustness of the proposed method. The proposed method shows the segmentation accuracy of 100%. Furthermore, the average processing time of the proposed method is 22 ms for an acquired image, which satisfies the criterion of a real-time finger vein identification system.

  20. Number magnitude to finger mapping is disembodied and topological.

    PubMed

    Plaisier, Myrthe A; Smeets, Jeroen B J

    2011-03-01

    It has been shown that humans associate fingers with numbers because finger counting strategies interact with numerical judgements. At the same time, there is evidence that there is a relation between number magnitude and space as small to large numbers seem to be represented from left to right. In the present study, we investigated whether number magnitude to finger mapping is embodied (related to the order of fingers on the hand) or disembodied (spatial). We let healthy human volunteers name random numbers between 1 and 30, while simultaneously tapping a random finger. Either the hands were placed directly next to each other, 30 cm apart, or the hands were crossed such that the left hand was on the right side of the body mid-line. The results show that naming a smaller number than the previous one was associated with tapping a finger to the left of the previously tapped finger. This shows that there is a spatial (disembodied) mapping between number magnitude and fingers. Furthermore, we show that this mapping is topological rather than metrically scaled.

  1. Robust Finger Vein ROI Localization Based on Flexible Segmentation

    PubMed Central

    Lu, Yu; Xie, Shan Juan; Yoon, Sook; Yang, Jucheng; Park, Dong Sun

    2013-01-01

    Finger veins have been proved to be an effective biometric for personal identification in the recent years. However, finger vein images are easily affected by influences such as image translation, orientation, scale, scattering, finger structure, complicated background, uneven illumination, and collection posture. All these factors may contribute to inaccurate region of interest (ROI) definition, and so degrade the performance of finger vein identification system. To improve this problem, in this paper, we propose a finger vein ROI localization method that has high effectiveness and robustness against the above factors. The proposed method consists of a set of steps to localize ROIs accurately, namely segmentation, orientation correction, and ROI detection. Accurate finger region segmentation and correct calculated orientation can support each other to produce higher accuracy in localizing ROIs. Extensive experiments have been performed on the finger vein image database, MMCBNU_6000, to verify the robustness of the proposed method. The proposed method shows the segmentation accuracy of 100%. Furthermore, the average processing time of the proposed method is 22 ms for an acquired image, which satisfies the criterion of a real-time finger vein identification system. PMID:24284769

  2. Finger vein extraction using gradient normalization and principal curvature

    NASA Astrophysics Data System (ADS)

    Choi, Joon Hwan; Song, Wonseok; Kim, Taejeong; Lee, Seung-Rae; Kim, Hee Chan

    2009-02-01

    Finger vein authentication is a personal identification technology using finger vein images acquired by infrared imaging. It is one of the newest technologies in biometrics. Its main advantage over other biometrics is the low risk of forgery or theft, due to the fact that finger veins are not normally visible to others. Extracting finger vein patterns from infrared images is the most difficult part in finger vein authentication. Uneven illumination, varying tissues and bones, and changes in the physical conditions and the blood flow make the thickness and brightness of the same vein different in each acquisition. Accordingly, extracting finger veins at their accurate positions regardless of their thickness and brightness is necessary for accurate personal identification. For this purpose, we propose a new finger vein extraction method which is composed of gradient normalization, principal curvature calculation, and binarization. As local brightness variation has little effect on the curvature and as gradient normalization makes the curvature fairly uniform at vein pixels, our method effectively extracts finger vein patterns regardless of the vein thickness or brightness. In our experiment, the proposed method showed notable improvement as compared with the existing methods.

  3. Application of Copper-Chitosan Nanoparticles Stimulate Growth and Induce Resistance in Finger Millet (Eleusine coracana Gaertn.) Plants against Blast Disease.

    PubMed

    Sathiyabama, Muthukrishnan; Manikandan, Appu

    2018-02-28

    Copper-chitosan nanoparticle (CuChNp) was synthesized and used to study its effect on finger millet plant as a model plant system. Our objective was to explore the efficacy of CuChNp application to control blast disease of finger millet. CuChNp was applied to finger millet either as a foliar spray or as a combined application (involving seed coat and foliar spray). Both the application methods enhanced growth profile of finger millet plants and increased yield. The increased yield was nearly 89% in combined application method. Treated finger millet plants challenged with Pyricularia grisea showed suppression of blast disease development when compared to control. Nearly 75% protection was observed in the combined application of CuChNp to finger millet plants. In CuChNp treated finger millet plants, a significant increase in defense enzymes was observed, which was detected both qualitatively and quantitatively. The suppression of blast disease correlates well with increased defense enzymes in CuChNp treated finger millet plants.

  4. X-Ray Exam: Finger

    MedlinePlus

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Finger KidsHealth / For Parents / X-Ray Exam: Finger What's in this article? What ... Have Questions Print What It Is A finger X-ray is a safe and painless test that ...

  5. Vibration energy absorption (VEA) in human fingers-hand-arm system.

    PubMed

    Dong, R G; Schopper, A W; McDowell, T W; Welcome, D E; Wu, J Z; Smutz, W P; Warren, C; Rakheja, S

    2004-07-01

    A methodology for measuring the vibration energy absorbed into the fingers and the palm exposed to vibration is proposed to study the distribution of the vibration energy absorption (VEA) in the fingers-hand-arm system and to explore its potential association with vibration-induced white finger (VWF). The study involved 12 adult male subjects, constant-velocity sinusoidal excitations at 10 different discrete frequencies in the range of 16-1000 Hz, and four different hand-handle coupling conditions (finger pull-only, hand grip-only, palm push-only, and combined grip and push). The results of the study suggest that the VEA into the fingers is considerably less than that into the palm at low frequencies (< or = 25 Hz). They are, however, comparable under the excitations in the 250-1000 Hz frequency range. The finger VEA at high frequencies (> or = 100 Hz) is practically independent of the hand-handle coupling condition. The coupling conditions affect the VEA into the fingers and the palm very differently. The finger VEA results suggest that the ISO standardized frequency weighting (ISO 5349-1, 2001) may underestimate the effect of high frequency vibration on vibration-induced finger disorders. The proposed method may provide new opportunities to examine VEA and its association with VWF and other types of vibration-induced disorders in the hand-arm system.

  6. Evaluation of finger millet incorporated noodles for nutritive value and glycemic index.

    PubMed

    Shukla, Kamini; Srivastava, Sarita

    2014-03-01

    The present study was undertaken to develop finger millet incorporated noodles for diabetic patients. Finger millet variety VL-149 was taken. The finger millet flour and refined wheat flour (RWF) were evaluated for nutrient composition. The finger millet flour (FMF) was blended in various proportions (30 to 50%) in refined wheat flour and used for the preparation of noodles. Control consisted of RWF noodles. Sensory quality and nutrient composition of finger millet noodles was evaluated. The 30% finger millet incorporated noodles were selected best on the basis of sensory evaluation. Noodles in that proportion along with control were evaluated for glycemic response. Nutrient composition of noodles showed that 50% finger millet incorporated noodles contained highest amount of crude fat (1.15%), total ash (1.40%), crude fiber (1.28%), carbohydrate (78.54%), physiological energy (351.36 kcal), insoluble dietary fiber (5.45%), soluble dietary fiber (3.71%), iron (5.58%) and calcium (88.39%), respectively. However, control RWF noodles contained highest amount of starch (63.02%), amylose (8.72%) and amylopectin (54.29%). The glycemic index (GI) of 30% finger millet incorporated noodles (best selected by sensory evaluation) was observed significantly lower (45.13) than control noodles (62.59). It was found that finger millet flour incorporated noodles were found nutritious and showed hypoglycemic effect.

  7. Comparative analyses reveal high levels of conserved colinearity between the finger millet and rice genomes.

    PubMed

    Srinivasachary; Dida, Mathews M; Gale, Mike D; Devos, Katrien M

    2007-08-01

    Finger millet is an allotetraploid (2n = 4x = 36) grass that belongs to the Chloridoideae subfamily. A comparative analysis has been carried out to determine the relationship of the finger millet genome with that of rice. Six of the nine finger millet homoeologous groups corresponded to a single rice chromosome each. Each of the remaining three finger millet groups were orthologous to two rice chromosomes, and in all the three cases one rice chromosome was inserted into the centromeric region of a second rice chromosome to give the finger millet chromosomal configuration. All observed rearrangements were, among the grasses, unique to finger millet and, possibly, the Chloridoideae subfamily. Gene orders between rice and finger millet were highly conserved, with rearrangements being limited largely to single marker transpositions and small putative inversions encompassing at most three markers. Only some 10% of markers mapped to non-syntenic positions in rice and finger millet and the majority of these were located in the distal 14% of chromosome arms, supporting a possible correlation between recombination and sequence evolution as has previously been observed in wheat. A comparison of the organization of finger millet, Panicoideae and Pooideae genomes relative to rice allowed us to infer putative ancestral chromosome configurations in the grasses.

  8. Quantifying Parkinson's disease finger-tapping severity by extracting and synthesizing finger motion properties.

    PubMed

    Sano, Yuko; Kandori, Akihiko; Shima, Keisuke; Yamaguchi, Yuki; Tsuji, Toshio; Noda, Masafumi; Higashikawa, Fumiko; Yokoe, Masaru; Sakoda, Saburo

    2016-06-01

    We propose a novel index of Parkinson's disease (PD) finger-tapping severity, called "PDFTsi," for quantifying the severity of symptoms related to the finger tapping of PD patients with high accuracy. To validate the efficacy of PDFTsi, the finger-tapping movements of normal controls and PD patients were measured by using magnetic sensors, and 21 characteristics were extracted from the finger-tapping waveforms. To distinguish motor deterioration due to PD from that due to aging, the aging effect on finger tapping was removed from these characteristics. Principal component analysis (PCA) was applied to the age-normalized characteristics, and principal components that represented the motion properties of finger tapping were calculated. Multiple linear regression (MLR) with stepwise variable selection was applied to the principal components, and PDFTsi was calculated. The calculated PDFTsi indicates that PDFTsi has a high estimation ability, namely a mean square error of 0.45. The estimation ability of PDFTsi is higher than that of the alternative method, MLR with stepwise regression selection without PCA, namely a mean square error of 1.30. This result suggests that PDFTsi can quantify PD finger-tapping severity accurately. Furthermore, the result of interpreting a model for calculating PDFTsi indicated that motion wideness and rhythm disorder are important for estimating PD finger-tapping severity.

  9. Three-dimensional Rayleigh-Taylor convection of miscible fluids in a porous medium

    NASA Astrophysics Data System (ADS)

    Suekane, Tetsuya; Nakanishi, Yuji; Wang, Lei

    2017-11-01

    Natural convection of miscible fluids in a porous medium is relevant for fields, such as geoscience and geoengineering, and for the geological storage of CO2. In this study, we use X-ray computer tomography to visualize 3D fingering structures associated with the Rayleigh-Taylor instability between miscible fluids in a porous medium. In the early stages of the onset of the Rayleigh-Taylor instability, a fine crinkling pattern gradually appears at the interface. As the wavelength and amplitude increase, descending fingers form on the interface and extend vertically downward; moreover, ascending and highly symmetric fingers form. The adjacent fingers are cylindrical in shape and coalesce to form large fingers. Fingers appearing on the interface tend to become finer with increasing Rayleigh number, which is consistent with linear perturbation theory. If the Péclet number exceeds 10, the transverse dispersion increases the finger diameter and enhances finger coalescence, strongly impacting the decay in finger number density. When mechanical dispersion is negligible, the finger-extension velocity, the mass-transfer rate, and the onset time scale with Rayleigh number. Mechanical dispersion not only reduces the onset time but also enhances mass transport, which indicates that mechanical dispersion influences the long-term dissolution process of CO2 injected into aquifers.

  10. Ultrafast High-Resolution Mass Spectrometric Finger Pore Imaging in Latent Finger Prints

    NASA Astrophysics Data System (ADS)

    Elsner, Christian; Abel, Bernd

    2014-11-01

    Latent finger prints (LFPs) are deposits of sweat components in ridge and groove patterns, left after human fingers contact with a surface. Being important targets in biometry and forensic investigations they contain more information than topological patterns. With laser desorption mass spectrometry imaging (LD-MSI) we record `three-dimensional' finger prints with additional chemical information as the third dimension. Here we show the potential of fast finger pore imaging (FPI) in latent finger prints employing LD-MSI without a classical matrix in a high- spatial resolution mode. Thin films of gold rapidly sputtered on top of the sample are used for desorption. FPI employing an optical image for rapid spatial orientation and guiding of the desorption laser enables the rapid analysis of individual finger pores, and the chemical composition of their excretions. With this approach we rapidly detect metabolites, drugs, and characteristic excretions from the inside of the human organism by a minimally-invasive strategy, and distinguish them from chemicals in contact with fingers without any labeling. The fast finger pore imaging, analysis, and screening approach opens the door for a vast number of novel applications in such different fields as forensics, doping and medication control, therapy, as well as rapid profiling of individuals.

  11. Equifinality and its violations in a redundant system: multifinger accurate force production.

    PubMed

    Wilhelm, Luke; Zatsiorsky, Vladimir M; Latash, Mark L

    2013-10-01

    We explored a hypothesis that transient perturbations applied to a redundant system result in equifinality in the space of task-related performance variables but not in the space of elemental variables. The subjects pressed with four fingers and produced an accurate constant total force level. The "inverse piano" device was used to lift and lower one of the fingers smoothly. The subjects were instructed "not to intervene voluntarily" with possible force changes. Analysis was performed in spaces of finger forces and finger modes (hypothetical neural commands to fingers) as elemental variables. Lifting a finger led to an increase in its force and a decrease in the forces of the other three fingers; the total force increased. Lowering the finger back led to a drop in the force of the perturbed finger. At the final state, the sum of the variances of finger forces/modes computed across repetitive trials was significantly higher than the variance of the total force/mode. Most variance of the individual finger force/mode changes between the preperturbation and postperturbation states was compatible with constant total force. We conclude that a transient perturbation applied to a redundant system leads to relatively small variance in the task-related performance variable (equifinality), whereas in the space of elemental variables much more variance occurs that does not lead to total force changes. We interpret the results within a general theoretical scheme that incorporates the ideas of hierarchically organized control, control with referent configurations, synergic control, and the uncontrolled manifold hypothesis.

  12. Speed invariance of independent control of finger movements in pianists

    PubMed Central

    Soechting, John F.

    2012-01-01

    Independent control of finger movements characterizes skilled motor behaviors such as tool use and musical performance. The purpose of the present study was to identify the effect of movement frequency (tempo) on individuated finger movements in piano playing. Joint motion at the digits was recorded while 5 expert pianists were playing 30 excerpts from musical pieces with different fingering and key locations either at a predetermined normal tempo or as fast as possible. Principal component analysis and cluster analysis using an expectation-maximization algorithm determined three distinct patterns of finger movement coordination for a keypress with each of the index, middle, ring, and little fingers at each of the two tempi. The finger kinematics of each coordination pattern was overall similar across the tempi. Tone sequences assigned into each cluster were also similar for both tempi. A linear regression analysis determined no apparent difference in the amount of movement covariation between the striking and nonstriking fingers at both metacarpo-phalangeal and proximal-interphalangeal joints across the two tempi, which indicated no effect of tempo on independent finger movements in piano playing. In addition, the standard deviation of interkeystroke interval across strokes did not differ between the two tempi, indicating maintenance of rhythmic accuracy of keystrokes. Strong temporal constraints on finger movements during piano playing may underlie the maintained independent control of fingers over a wider range of tempi, a feature being likely to be specific to skilled pianists. PMID:22815403

  13. Torque Control of Underactuated Tendon-driven Robotic Fingers

    NASA Technical Reports Server (NTRS)

    Ihrke, Chris A. (Inventor); Wampler, Charles W. (Inventor); Abdallah, Muhammad E. (Inventor); Reiland, Matthew J. (Inventor); Diftler, Myron A. (Inventor); Bridgwater, Lyndon (Inventor); Platt, Robert (Inventor)

    2013-01-01

    A robotic system includes a robot having a total number of degrees of freedom (DOF) equal to at least n, an underactuated tendon-driven finger driven by n tendons and n DOF, the finger having at least two joints, being characterized by an asymmetrical joint radius in one embodiment. A controller is in communication with the robot, and controls actuation of the tendon-driven finger using force control. Operating the finger with force control on the tendons, rather than position control, eliminates the unconstrained slack-space that would have otherwise existed. The controller may utilize the asymmetrical joint radii to independently command joint torques. A method of controlling the finger includes commanding either independent or parameterized joint torques to the controller to actuate the fingers via force control on the tendons.

  14. Finger movement at birth in brachial plexus birth palsy

    PubMed Central

    Nath, Rahul K; Benyahia, Mohamed; Somasundaram, Chandra

    2013-01-01

    AIM: To investigate whether the finger movement at birth is a better predictor of the brachial plexus birth injury. METHODS: We conducted a retrospective study reviewing pre-surgical records of 87 patients with residual obstetric brachial plexus palsy in study 1. Posterior subluxation of the humeral head (PHHA), and glenoid retroversion were measured from computed tomography or Magnetic resonance imaging, and correlated with the finger movement at birth. The study 2 consisted of 141 obstetric brachial plexus injury patients, who underwent primary surgeries and/or secondary surgery at the Texas Nerve and Paralysis Institute. Information regarding finger movement was obtained from the patient’s parent or guardian during the initial evaluation. RESULTS: Among 87 patients, 9 (10.3%) patients who lacked finger movement at birth had a PHHA > 40%, and glenoid retroversion < -12°, whereas only 1 patient (1.1%) with finger movement had a PHHA > 40%, and retroversion < -8° in study 1. The improvement in glenohumeral deformity (PHHA, 31.8% ± 14.3%; and glenoid retroversion 22.0° ± 15.0°) was significantly higher in patients, who have not had any primary surgeries and had finger movement at birth (group 1), when compared to those patients, who had primary surgeries (nerve and muscle surgeries), and lacked finger movement at birth (group 2), (PHHA 10.7% ± 15.8%; Version -8.0° ± 8.4°, P = 0.005 and P = 0.030, respectively) in study 2. No finger movement at birth was observed in 55% of the patients in this study group. CONCLUSION: Posterior subluxation and glenoid retroversion measurements indicated significantly severe shoulder deformities in children with finger movement at birth, in comparison with those lacked finger movement. However, the improvement after triangle tilt surgery was higher in patients who had finger movement at birth. PMID:23362472

  15. On the relationship between finger width, velocity, and fluxes in thermohaline convection

    NASA Astrophysics Data System (ADS)

    Sreenivas, K. R.; Singh, O. P.; Srinivasan, J.

    2009-02-01

    Double-diffusive finger convection occurs in many natural processes. The theories for double-diffusive phenomena that exist at present consider systems with linear stratification in temperature and salinity. The double-diffusive systems with step change in salinity and temperature are, however, not amenable to simple stability analysis. Hence factors that control the width of the finger, velocity, and fluxes in systems that have step change in temperature and salinity have not been understood so far. In this paper we provide new physical insight regarding factors that influence finger convection in two-layer double-diffusive system through two-dimensional numerical simulations. Simulations have been carried out for density stability ratios (Rρ) from 1.5 to 10. For each density stability ratio, the thermal Rayleigh number (RaT) has been systematically varied from 7×103 to 7×108. Results from these simulations show how finger width, velocity, and flux ratios in finger convection are interrelated and the influence of governing parameters such as density stability ratio and the thermal Rayleigh number. The width of the incipient fingers at the time of onset of instability has been shown to vary as RaT-1/3. Velocity in the finger varies as RaT1/3/Rρ. Results from simulation agree with the scale analysis presented in the paper. Our results demonstrate that wide fingers have lower velocities and flux ratios compared to those in narrow fingers. This result contradicts present notions about the relation between finger width and flux ratio. A counterflow heat-exchanger analogy is used in understanding the dependence of flux ratio on finger width and velocity.

  16. Hand rehabilitation using MIDI keyboard playing in adolescents with brain damage: a preliminary study.

    PubMed

    Chong, Hyun Ju; Cho, Sung-Rae; Kim, Soo Ji

    2014-01-01

    As a sequential, programmed movement of fingers, keyboard playing is a promising technique for inducing execution and a high level of coordination during finger movements. Also, keyboard playing can be physically and emotionally rewarding for adolescents in rehabilitation settings and thereby motivate continued involvement in treatment. The purpose of this study is to evaluate the effects of keyboard playing using Musical Instrument Digital Interface (MIDI) on finger movement for adolescents with brain damage. Eight adolescents with brain damage, ages 9 to 18 years (M = 13 years, SD = 2.78), in physical rehabilitation settings participated in this study. Measurements included MIDI keyboard playing for pressing force of the fingers and hand function tests (Grip and Pinch Power Test, Box and Block Test of Manual Dexterity [BBT], and the Jebsen Taylor Hand Function Test). Results showed increased velocity of all fingers on the MIDI-based test, and statistical significance was found in the velocity of F2 (index finger), F3 (middle finger), and F5 (little finger) between pre- and post-training tests. Correlation analysis between the pressing force of the finger and hand function tests showed a strong positive correlation between the measure of grip power and the pressing force of F2 and F5 on the Grip and Pinch Strength Test. All fingers showed strong correlation between MIDI results and BBT. For the Jebsen Taylor Hand Function Test, only the moving light objects task at post-training yielded strong correlation with MIDI results of all fingers. The results support using keyboard playing for hand rehabilitation, especially in the pressing force of individual finger sequential movements. Further investigation is needed to define the feasibility of the MIDI program for valid hand rehabilitation for people with brain damage.

  17. Three-dimensional viscous fingering of miscible fluids in porous media

    NASA Astrophysics Data System (ADS)

    Suekane, Tetsuya; Ono, Jei; Hyodo, Akimitsu; Nagatsu, Yuichiro

    2017-10-01

    Viscous fingering is a flow instability that is induced at the displacement front when a less-viscous fluid (LVF) displaces a more-viscous fluid (MVF). Because of the opaque nature of porous media, most experimental investigations of the structure of viscous fingering and its development in time have been limited to two-dimensional porous media or Hele-Shaw cells. In this study, we investigate the three-dimensional characteristics of viscous fingering in porous media using a microfocused x-ray computer tomography (CT) scanner. Similar to two-dimensional experiments, characteristic events such as tip-splitting, shielding, and coalescence were observed in three-dimensional viscous fingering as well. With an increase in the Péclet number at a fixed viscosity ratio, M , the fingers appearing on the interface tend to be fine; however, the locations of the tips of the fingers remain the same for the same injected volume of the LVF. The finger extensions increase in proportion to ln M , and the number of fingers emerging at the initial interface increases with M . This fact agrees qualitatively with linear stability analyses. Within the fingers, the local concentration of NaI, which is needed for the x-ray CT scanner, linearly decreases, whereas it sharply decreases at the tips of the fingers. A locally high Péclet number as well as unsteady motions in lateral directions may enhance the dispersion at the tips of the fingers. As the viscosity ratio increases, the efficiency of each sweep monotonically decreases and reaches an asymptotic state; in addition, the degree of mixing increases with the viscosity ratio. For high flow rates, the asymptotic value of the sweep efficiency is low for high viscosity ratios, while there is no clear dependence of the asymptotic value on the Péclet number.

  18. Involuntary Neuromuscular Coupling between the Thumb and Finger of Stroke Survivors during Dynamic Movement.

    PubMed

    Jones, Christopher L; Kamper, Derek G

    2018-01-01

    Finger-thumb coordination is crucial to manual dexterity but remains incompletely understood, particularly following neurological injury such as stroke. While being controlled independently, the index finger and thumb especially must work in concert to perform a variety of tasks requiring lateral or palmar pinch. The impact of stroke on this functionally critical sensorimotor control during dynamic tasks has been largely unexplored. In this study, we explored finger-thumb coupling during close-open pinching motions in stroke survivors with chronic hemiparesis. Two types of perturbations were applied randomly to the index with a novel Cable-Actuated Finger Exoskeleton: a sudden joint acceleration stretching muscle groups of the index finger and a sudden increase in impedance in selected index finger joint(s). Electromyographic signals for specific thumb and index finger muscles, thumb tip trajectory, and index finger joint angles were recorded during each trial. Joint angle perturbations invoked reflex responses in the flexor digitorum superficialis (FDS), first dorsal interossei (FDI), and extensor digitorum communis muscles of the index finger and heteronymous reflex responses in flexor pollicis brevis of the thumb ( p  < 0.017). Phase of movement played a role as a faster peak reflex response was observed in FDI during opening than during closing ( p  < 0.002) and direction of perturbations resulted in shorter reflex times for FDS and FDI ( p  < 0.012) for extension perturbations. Surprisingly, when index finger joint impedance was suddenly increased, thumb tip movement was substantially increased, from 2 to 10 cm ( p  < 0.001). A greater effect was seen during the opening phase ( p  < 0.044). Thus, involuntary finger-thumb coupling was present during dynamic movement, with perturbation of the index finger impacting thumb activity. The degree of coupling modulated with the phase of motion. These findings reveal a potential mechanism for direct intervention to improve poststroke hand mobility and provide insight on prospective neurologically oriented therapies.

  19. Finger Forces in Clarinet Playing

    PubMed Central

    Hofmann, Alex; Goebl, Werner

    2016-01-01

    Clarinettists close and open multiple tone holes to alter the pitch of the tones. Their fingering technique must be fast, precise, and coordinated with the tongue articulation. In this empirical study, finger force profiles and tongue techniques of clarinet students (N = 17) and professional clarinettists (N = 6) were investigated under controlled performance conditions. First, in an expressive-performance task, eight selected excerpts from the first Weber Concerto were performed. These excerpts were chosen to fit in a 2 × 2 × 2 design (register: low–high; tempo: slow–fast, dynamics: soft–loud). There was an additional condition controlled by the experimenter, which determined the expression levels (low–high) of the performers. Second, a technical-exercise task, an isochronous 23-tone melody was designed that required different effectors to produce the sequence (finger-only, tongue-only, combined tongue-finger actions). The melody was performed in three tempo conditions (slow, medium, fast) in a synchronization-continuation paradigm. Participants played on a sensor-equipped Viennese clarinet, which tracked finger forces and reed oscillations simultaneously. From the data, average finger force (Fmean) and peak force (Fmax) were calculated. The overall finger forces were low (Fmean = 1.17 N, Fmax = 3.05 N) compared to those on other musical instruments (e.g., guitar). Participants applied the largest finger forces during the high expression level performance conditions (Fmean = 1.21 N). For the technical exercise task, timing and articulation information were extracted from the reed signal. Here, the timing precision of the fingers deteriorated the timing precision of the tongue for combined tongue-finger actions, especially for faster tempi. Although individual finger force profiles were overlapping, the group of professional players applied less finger force overall (Fmean = 0.54 N). Such sensor instruments provide useful insights into player-instrument interactions and can also be used in the future to give feedback to students in various learning and practising situations. PMID:27540367

  20. Finger vein verification system based on sparse representation.

    PubMed

    Xin, Yang; Liu, Zhi; Zhang, Haixia; Zhang, Hong

    2012-09-01

    Finger vein verification is a promising biometric pattern for personal identification in terms of security and convenience. The recognition performance of this technology heavily relies on the quality of finger vein images and on the recognition algorithm. To achieve efficient recognition performance, a special finger vein imaging device is developed, and a finger vein recognition method based on sparse representation is proposed. The motivation for the proposed method is that finger vein images exhibit a sparse property. In the proposed system, the regions of interest (ROIs) in the finger vein images are segmented and enhanced. Sparse representation and sparsity preserving projection on ROIs are performed to obtain the features. Finally, the features are measured for recognition. An equal error rate of 0.017% was achieved based on the finger vein image database, which contains images that were captured by using the near-IR imaging device that was developed in this study. The experimental results demonstrate that the proposed method is faster and more robust than previous methods.

  1. Compact Dexterous Robotic Hand

    NASA Technical Reports Server (NTRS)

    Lovchik, Christopher Scott (Inventor); Diftler, Myron A. (Inventor)

    2001-01-01

    A compact robotic hand includes a palm housing, a wrist section, and a forearm section. The palm housing supports a plurality of fingers and one or more movable palm members that cooperate with the fingers to grasp and/or release an object. Each flexible finger comprises a plurality of hingedly connected segments, including a proximal segment pivotally connected to the palm housing. The proximal finger segment includes at least one groove defining first and second cam surfaces for engagement with a cable. A plurality of lead screw assemblies each carried by the palm housing are supplied with power from a flexible shaft rotated by an actuator and output linear motion to a cable move a finger. The cable is secured within a respective groove and enables each finger to move between an opened and closed position. A decoupling assembly pivotally connected to a proximal finger segment enables a cable connected thereto to control movement of an intermediate and distal finger segment independent of movement of the proximal finger segment. The dexterous robotic hand closely resembles the function of a human hand yet is light weight and capable of grasping both heavy and light objects with a high degree of precision.

  2. Numerical study on tilting salt finger in a laminar shear flow

    NASA Astrophysics Data System (ADS)

    Zhang, Xianfei; Wang, Ling-ling; Lin, Cheng; Zhu, Hai; Zeng, Cheng

    2018-02-01

    Salt fingers as a mixing mechanism in the ocean have been investigated for several decades, together with a key issue being focused on their convective evolution and flux ratio variation. However, related studies on tilting fingers in the ocean produced by shear flow have been ignored by previous researchers. In this paper, a 2-D numerical model is presented to study the evolution of the double-diffusion salt finger in a two-layer thermohaline system with laminar shear flow. The model is divided into a steady-state solver and double-diffusion convection system, aimed to reveal the effect of shear flow on salt fingers and analyze the mechanism behind the shear and fingers. Several cases are conducted for Re = 0 ˜ 900 to study the evolution of salt fingers in a laminar shear flow and the variation of salt flux with Re. The results show that salt fingers exist and tilt in the presence of laminar shear flow. The mass transport in the vertical direction is weakened as the Reynolds number increases. An asymmetric structure of the salt finger is discovered and accounts for the morphological tilt and salt flux reduction.

  3. Losing dexterity: patterns of impaired coordination of finger movements in musician’s dystonia

    PubMed Central

    Furuya, Shinichi; Tominaga, Kenta; Miyazaki, Fumio; Altenmüller, Eckart

    2015-01-01

    Extensive training can bring about highly-skilled action, but may also impair motor dexterity by producing involuntary movements and muscular cramping, as seen in focal dystonia (FD) and tremor. To elucidate the underlying neuroplastic mechanisms of FD, the present study addressed the organization of finger movements during piano performance in pianists suffering from the condition. Principal component (PC) analysis identified three patterns of fundamental joint coordination constituting finger movements in both patients and controls. The first two coordination patterns described less individuated movements between the “dystonic” finger and key-striking fingers for patients compared to controls. The third coordination pattern, representing the individuation of movements between the middle and ring fingers, was evident during a sequence of strikes with these fingers in controls, which was absent in the patients. Consequently, rhythmic variability of keystrokes was more pronounced during this sequence of strikes for the patients. A stepwise multiple-regression analysis further identified greater variability of keystrokes for individuals displaying less individuated movements between the affected and striking fingers. The findings suggest that FD alters dexterous joint coordination so as to lower independent control of finger movements, and thereby degrades fine motor control. PMID:26289433

  4. The effect of an instant hand sanitizer on blood glucose monitoring results.

    PubMed

    Mahoney, John J; Ellison, John M; Glaeser, Danielle; Price, David

    2011-11-01

    People with diabetes mellitus are instructed to clean their skin prior to self-monitoring of blood glucose to remove any dirt or food residue that might affect the reading. Alcohol-based hand sanitizers have become popular when soap and water are not available. The aim of this study was to determine whether a hand sanitizer is compatible with glucose meter testing and effective for the removal of exogenous glucose. We enrolled 34 nonfasting subjects [14 male/20 female, mean ages 45 (standard deviation, 9.4)] years, 2 with diagnosed diabetes/32 without known diabetes]. Laboratory personnel prepared four separate fingers on one hand of each subject by (1) cleaning the second finger with soap and water and towel drying (i.e., control finger), (2) cleaning the third finger with an alcohol-based hand sanitizer, (3) coating the fourth finger with cola and allowing it to air dry, and (4) coating the fifth finger with cola and then cleaning it with the instant hand sanitizer after the cola had dried. Finger sticks were performed on each prepared finger and blood glucose was measured. Several in vitro studies were also performed to investigate the effectiveness of the hand sanitizer for removal of exogenous glucose.z Mean blood glucose values from fingers cleaned with instant hand sanitizer did not differ significantly from the control finger (p = .07 and .08, respectively) and resulted in 100% accurate results. Blood glucose data from the fourth (cola-coated) finger were substantially higher on average compared with the other finger conditions, but glucose data from the fifth finger (cola-coated then cleaned with hand sanitizer) was similar to the control finger. The data from in vitro experiments showed that the hand sanitizer did not adversely affect glucose meter results, but when an exogenous glucose interference was present, the effectiveness of the hand sanitizer on glucose bias (range: 6% to 212%) depended on the surface area and degree of dilution. In our study, use of an instant hand sanitizer was compatible with the results of a blood glucose monitor and did not affect finger stick blood glucose results. However, depending on surface area, hand sanitizers may not be adequate for cleaning the skin prior to glucose meter testing. © 2011 Diabetes Technology Society.

  5. The Effect of an Instant Hand Sanitizer on Blood Glucose Monitoring Results

    PubMed Central

    Mahoney, John J; Ellison, John M; Glaeser, Danielle; Price, David

    2011-01-01

    Background People with diabetes mellitus are instructed to clean their skin prior to self-monitoring of blood glucose to remove any dirt or food residue that might affect the reading. Alcohol-based hand sanitizers have become popular when soap and water are not available. The aim of this study was to determine whether a hand sanitizer is compatible with glucose meter testing and effective for the removal of exogenous glucose. Methods We enrolled 34 nonfasting subjects [14 male/20 female, mean ages 45 (standard deviation, 9.4)] years, 2 with diagnosed diabetes/32 without known diabetes]. Laboratory personnel prepared four separate fingers on one hand of each subject by (1) cleaning the second finger with soap and water and towel drying (i.e., control finger), (2) cleaning the third finger with an alcohol-based hand sanitizer, (3) coating the fourth finger with cola and allowing it to air dry, and (4) coating the fifth finger with cola and then cleaning it with the instant hand sanitizer after the cola had dried. Finger sticks were performed on each prepared finger and blood glucose was measured. Several in vitro studies were also performed to investigate the effectiveness of the hand sanitizer for removal of exogenous glucose.z Results Mean blood glucose values from fingers cleaned with instant hand sanitizer did not differ significantly from the control finger (p = .07 and .08, respectively) and resulted in 100% accurate results. Blood glucose data from the fourth (cola-coated) finger were substantially higher on average compared with the other finger conditions, but glucose data from the fifth finger (cola-coated then cleaned with hand sanitizer) was similar to the control finger. The data from in vitro experiments showed that the hand sanitizer did not adversely affect glucose meter results, but when an exogenous glucose interference was present, the effectiveness of the hand sanitizer on glucose bias (range: 6% to 212%) depended on the surface area and degree of dilution. Conclusions In our study, use of an instant hand sanitizer was compatible with the results of a blood glucose monitor and did not affect finger stick blood glucose results. However, depending on surface area, hand sanitizers may not be adequate for cleaning the skin prior to glucose meter testing. PMID:22226262

  6. 21 CFR 888.3220 - Finger joint metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Finger joint metal/polymer constrained cemented... metal/polymer constrained cemented prosthesis. (a) Identification. A finger joint metal/polymer..., 1996 for any finger joint metal/polymer constrained cemented prosthesis that was in commercial...

  7. 21 CFR 888.3230 - Finger joint polymer constrained prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Finger joint polymer constrained prosthesis. 888... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3230 Finger joint polymer constrained prosthesis. (a) Identification. A finger joint polymer constrained prosthesis is a device intended...

  8. 21 CFR 888.3220 - Finger joint metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Finger joint metal/polymer constrained cemented... metal/polymer constrained cemented prosthesis. (a) Identification. A finger joint metal/polymer..., 1996 for any finger joint metal/polymer constrained cemented prosthesis that was in commercial...

  9. 21 CFR 888.3230 - Finger joint polymer constrained prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Finger joint polymer constrained prosthesis. 888... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3230 Finger joint polymer constrained prosthesis. (a) Identification. A finger joint polymer constrained prosthesis is a device intended...

  10. 21 CFR 888.3220 - Finger joint metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Finger joint metal/polymer constrained cemented... metal/polymer constrained cemented prosthesis. (a) Identification. A finger joint metal/polymer..., 1996 for any finger joint metal/polymer constrained cemented prosthesis that was in commercial...

  11. 21 CFR 888.3220 - Finger joint metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Finger joint metal/polymer constrained cemented... metal/polymer constrained cemented prosthesis. (a) Identification. A finger joint metal/polymer..., 1996 for any finger joint metal/polymer constrained cemented prosthesis that was in commercial...

  12. 21 CFR 888.3230 - Finger joint polymer constrained prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Finger joint polymer constrained prosthesis. 888... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3230 Finger joint polymer constrained prosthesis. (a) Identification. A finger joint polymer constrained prosthesis is a device intended...

  13. 21 CFR 888.3220 - Finger joint metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Finger joint metal/polymer constrained cemented... metal/polymer constrained cemented prosthesis. (a) Identification. A finger joint metal/polymer..., 1996 for any finger joint metal/polymer constrained cemented prosthesis that was in commercial...

  14. 21 CFR 888.3230 - Finger joint polymer constrained prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Finger joint polymer constrained prosthesis. 888... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3230 Finger joint polymer constrained prosthesis. (a) Identification. A finger joint polymer constrained prosthesis is a device intended...

  15. 21 CFR 888.3230 - Finger joint polymer constrained prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Finger joint polymer constrained prosthesis. 888... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3230 Finger joint polymer constrained prosthesis. (a) Identification. A finger joint polymer constrained prosthesis is a device intended...

  16. Association between finger tapping, attention, memory, and cognitive diagnosis in elderly patients.

    PubMed

    Rabinowitz, Israel; Lavner, Yizhar

    2014-08-01

    This study examined the association between spontaneous finger tapping and cognitive function, with a detailed analysis of the two main phases of finger tapping, the touch-phase and the off-phase. 170 elderly patients (83 men, 87 women; M age = 82.1 yr., SD = 6.2) underwent cognitive assessment including the Mini-Mental State Examination, a forward digit span test, and 15 sec. of finger tapping. Results indicated a significant increase in the length and variability of the finger-touch phase among participants with mild cognitive impairment or dementia compared to participants with no cognitive impairment, suggesting a relationship between finger tapping and attention, short-term memory, and cognitive diagnosis. Pattern classification analyses on the finger tapping parameters indicated a specificity of 0.91 and sensitivity of 0.52 for ruling out cognitive impairment.

  17. Equifinality and its violations in a redundant system: multifinger accurate force production

    PubMed Central

    Wilhelm, Luke; Zatsiorsky, Vladimir M.

    2013-01-01

    We explored a hypothesis that transient perturbations applied to a redundant system result in equifinality in the space of task-related performance variables but not in the space of elemental variables. The subjects pressed with four fingers and produced an accurate constant total force level. The “inverse piano” device was used to lift and lower one of the fingers smoothly. The subjects were instructed “not to intervene voluntarily” with possible force changes. Analysis was performed in spaces of finger forces and finger modes (hypothetical neural commands to fingers) as elemental variables. Lifting a finger led to an increase in its force and a decrease in the forces of the other three fingers; the total force increased. Lowering the finger back led to a drop in the force of the perturbed finger. At the final state, the sum of the variances of finger forces/modes computed across repetitive trials was significantly higher than the variance of the total force/mode. Most variance of the individual finger force/mode changes between the preperturbation and postperturbation states was compatible with constant total force. We conclude that a transient perturbation applied to a redundant system leads to relatively small variance in the task-related performance variable (equifinality), whereas in the space of elemental variables much more variance occurs that does not lead to total force changes. We interpret the results within a general theoretical scheme that incorporates the ideas of hierarchically organized control, control with referent configurations, synergic control, and the uncontrolled manifold hypothesis. PMID:23904497

  18. Single trial discrimination of individual finger movements on one hand: A combined MEG and EEG study☆

    PubMed Central

    Quandt, F.; Reichert, C.; Hinrichs, H.; Heinze, H.J.; Knight, R.T.; Rieger, J.W.

    2012-01-01

    It is crucial to understand what brain signals can be decoded from single trials with different recording techniques for the development of Brain-Machine Interfaces. A specific challenge for non-invasive recording methods are activations confined to small spatial areas on the cortex such as the finger representation of one hand. Here we study the information content of single trial brain activity in non-invasive MEG and EEG recordings elicited by finger movements of one hand. We investigate the feasibility of decoding which of four fingers of one hand performed a slight button press. With MEG we demonstrate reliable discrimination of single button presses performed with the thumb, the index, the middle or the little finger (average over all subjects and fingers 57%, best subject 70%, empirical guessing level: 25.1%). EEG decoding performance was less robust (average over all subjects and fingers 43%, best subject 54%, empirical guessing level 25.1%). Spatiotemporal patterns of amplitude variations in the time series provided best information for discriminating finger movements. Non-phase-locked changes of mu and beta oscillations were less predictive. Movement related high gamma oscillations were observed in average induced oscillation amplitudes in the MEG but did not provide sufficient information about the finger's identity in single trials. Importantly, pre-movement neuronal activity provided information about the preparation of the movement of a specific finger. Our study demonstrates the potential of non-invasive MEG to provide informative features for individual finger control in a Brain-Machine Interface neuroprosthesis. PMID:22155040

  19. Interaction of finger enslaving and error compensation in multiple finger force production.

    PubMed

    Martin, Joel R; Latash, Mark L; Zatsiorsky, Vladimir M

    2009-01-01

    Previous studies have documented two patterns of finger interaction during multi-finger pressing tasks, enslaving and error compensation, which do not agree with each other. Enslaving is characterized by positive correlation between instructed (master) and non-instructed (slave) finger(s) while error compensation can be described as a pattern of negative correlation between master and slave fingers. We hypothesize that pattern of finger interaction, enslaving or compensation depends on the initial force level and the magnitude of the targeted force change. Subjects were instructed to press with four fingers (I index, M middle, R ring, and L little) from a specified initial force to target forces following a ramp target line. Force-force relations between master and each of three slave fingers were analyzed during the ramp phase of trials by calculating correlation coefficients within each master-slave pair and then two-factor ANOVA was performed to determine effect of initial force and force increase on the correlation coefficients. It was found that, as initial force increased, the value of the correlation coefficient decreased and in some cases became negative, i.e. the enslaving transformed into error compensation. Force increase magnitude had a smaller effect on the correlation coefficients. The observations support the hypothesis that the pattern of inter-finger interaction--enslaving or compensation--depends on the initial force level and, to a smaller degree, on the targeted magnitude of the force increase. They suggest that the controller views tasks with higher steady-state forces and smaller force changes as implying a requirement to avoid large changes in the total force.

  20. 21 CFR 888.3210 - Finger joint metal/metal constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Finger joint metal/metal constrained cemented... metal/metal constrained cemented prosthesis. (a) Identification. A finger joint metal/metal constrained..., 1996 for any finger joint metal/metal constrained cemented prosthesis that was in commercial...

  1. 21 CFR 888.3210 - Finger joint metal/metal constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Finger joint metal/metal constrained cemented... metal/metal constrained cemented prosthesis. (a) Identification. A finger joint metal/metal constrained..., 1996 for any finger joint metal/metal constrained cemented prosthesis that was in commercial...

  2. 21 CFR 888.3200 - Finger joint metal/metal constrained uncemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Finger joint metal/metal constrained uncemented... metal/metal constrained uncemented prosthesis. (a) Identification. A finger joint metal/metal... Administration on or before December 26, 1996 for any finger joint metal/metal constrained uncemented prosthesis...

  3. 21 CFR 888.3200 - Finger joint metal/metal constrained uncemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Finger joint metal/metal constrained uncemented... metal/metal constrained uncemented prosthesis. (a) Identification. A finger joint metal/metal... Administration on or before December 26, 1996 for any finger joint metal/metal constrained uncemented prosthesis...

  4. Agility, gnosis, and graphaesthesia for the toes and fingers in children: normative data (ages 7-14 years).

    PubMed

    Richards, P M; Persinger, M A

    2004-01-01

    The differential representation of the toes/feet and fingers/hands along the medial and lateral surfaces of the cerebral cortices, respectively, may have diagnostic utility. Normative data for errors for toe and finger graphaesthesia and gnosis, as well as foot and finger agility, were collected for 86 children (ages 7 to 14). The fingers were more agile than the feet, and the right side of the body was more agile than the left side, regardless of age. A marked improvement in toe gnosis, but not in finger gnosis occurred in children after 11-12 years of age. A statistically significant interaction between laterality and gender was due to the greater numbers of errors for both toe and finger gnosis, displayed by girls for the left sides of their bodies compared to their right sides. This discrepancy was not significant for boys.

  5. Differences in finger localisation performance of patients with finger agnosia.

    PubMed

    Anema, Helen A; Kessels, Roy P C; de Haan, Edward H F; Kappelle, L Jaap; Leijten, Frans S; van Zandvoort, Martine J E; Dijkerman, H Chris

    2008-09-17

    Several neuropsychological studies have suggested parallel processing of somatosensory input when localising a tactile stimulus on one's own by pointing towards it (body schema) and when localising this touched location by pointing to it on a map of a hand (body image). Usually these reports describe patients with impaired detection, but intact sensorimotor localisation. This study examined three patients with a lesion of the angular gyrus with intact somatosensory processing, but with selectively disturbed finger identification (finger agnosia). These patients performed normally when pointing towards the touched finger on their own hand but failed to indicate this finger on a drawing of a hand or to name it. Similar defects in the perception of other body parts were not observed. The findings provide converging evidence for the dissociation between body image and body schema and, more importantly, reveal for the first time that this distinction is also present in higher-order cognitive processes selectively for the fingers.

  6. Finger vein recognition based on finger crease location

    NASA Astrophysics Data System (ADS)

    Lu, Zhiying; Ding, Shumeng; Yin, Jing

    2016-07-01

    Finger vein recognition technology has significant advantages over other methods in terms of accuracy, uniqueness, and stability, and it has wide promising applications in the field of biometric recognition. We propose using finger creases to locate and extract an object region. Then we use linear fitting to overcome the problem of finger rotation in the plane. The method of modular adaptive histogram equalization (MAHE) is presented to enhance image contrast and reduce computational cost. To extract the finger vein features, we use a fusion method, which can obtain clear and distinguishable vein patterns under different conditions. We used the Hausdorff average distance algorithm to examine the recognition performance of the system. The experimental results demonstrate that MAHE can better balance the recognition accuracy and the expenditure of time compared with three other methods. Our resulting equal error rate throughout the total procedure was 3.268% in a database of 153 finger vein images.

  7. 76 FR 77769 - North Finger Grazing Authorization Project, Malheur National Forest, Grant County, OR

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-14

    ... allotments within the North Finger Landscape. These allotments are within the Upper Deer Creek, Basin Creek... is to authorize grazing on all or portions of the North Finger landscape in such a manner that will... incorporating adaptive management strategies across the North Finger landscape. Adaptive Management is defined...

  8. Ergonomics Designs of Aluminum Beverage Cans & Bottles

    NASA Astrophysics Data System (ADS)

    Han, Jing; Itoh, Ryouiti; Yamazaki, Koetsu; Nishiyama, Sadao; Shinguryo, Takuro

    2005-08-01

    This paper introduced the finite element analyses into the ergonomics designs to evaluate the human feelings numerically and objectively. Two design examples in developing aluminum beverage cans & bottles are presented. The first example describes a design of the tab of the can with better finger access. A simulation of finger pulling up the tab of the can has been performed and a pain in the finger has been evaluated by using the maximum value of the contact stress of a finger model. The finger access comparison of three kinds of tab ring shape designs showed that the finger access of the tab that may have a larger contact area with finger is better. The second example describes a design of rib-shape embossed bottles for hot vending. Analyses of tactile sensation of heat have been performed and the amount of heat transmitted from hot bottles to finger was used to present the hot touch feeling. Comparison results showed that the hot touch feeling of rib-shape embossed bottles is better than that of cylindrical bottles, and that the shape of the rib also influenced the hot touch feeling.

  9. Finger gnosis predicts a unique but small part of variance in initial arithmetic performance.

    PubMed

    Wasner, Mirjam; Nuerk, Hans-Christoph; Martignon, Laura; Roesch, Stephanie; Moeller, Korbinian

    2016-06-01

    Recent studies indicated that finger gnosis (i.e., the ability to perceive and differentiate one's own fingers) is associated reliably with basic numerical competencies. In this study, we aimed at examining whether finger gnosis is also a unique predictor for initial arithmetic competencies at the beginning of first grade-and thus before formal math instruction starts. Therefore, we controlled for influences of domain-specific numerical precursor competencies, domain-general cognitive ability, and natural variables such as gender and age. Results from 321 German first-graders revealed that finger gnosis indeed predicted a unique and relevant but nevertheless only small part of the variance in initial arithmetic performance (∼1%-2%) as compared with influences of general cognitive ability and numerical precursor competencies. Taken together, these results substantiated the notion of a unique association between finger gnosis and arithmetic and further corroborate the theoretical idea of finger-based representations contributing to numerical cognition. However, the only small part of variance explained by finger gnosis seems to limit its relevance for diagnostic purposes. Copyright © 2016. Published by Elsevier Inc.

  10. Recognition of finger flexion motion from ultrasound image: a feasibility study.

    PubMed

    Shi, Jun; Guo, Jing-Yi; Hu, Shu-Xian; Zheng, Yong-Ping

    2012-10-01

    Muscle contraction results in structural and morphologic changes of the related muscle. Therefore, finger flexion can be monitored from measurements of these morphologic changes. We used ultrasound imaging to record muscle activities during finger flexion and extracted features to discriminate different fingers' flexions using a support vector machine (SVM). Registration of ultrasound images before and after finger flexion was performed to generate a deformation field, from which angle features and wavelet-based features were extracted. The SVM was then used to classify the motions of different fingers. The experimental results showed that the overall mean recognition accuracy was 94.05% ± 4.10%, with the highest for the thumb (97%) and the lowest for the ring finger (92%) and the mean F value was 0.94 ± 0.02, indicating high accuracy and reliability of this method. The results suggest that the proposed method has the potential to be used as an alternative method of surface electromyography in differentiating the motions of different fingers. Copyright © 2012 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  11. Finger length ratio (2D:4D) correlates with physical aggression in men but not in women.

    PubMed

    Bailey, Allison A; Hurd, Peter L

    2005-03-01

    Finger length ratio (2D:4D) is a sexually dimorphic trait. Men have relatively shorter second digits (index fingers) than fourth digits (ring fingers). Smaller, more masculine, digit ratios are thought to be associated with either higher prenatal testosterone levels or greater sensitivity to androgens, or both. Men with more masculine finger ratios are perceived as being more masculine and dominant by female observers, and tend to perform better in a number of physical sports. We hypothesized that digit ratio would correlate with propensity to engage in aggressive behavior. We examined the relationship between trait aggression, assayed using a questionnaire, and finger length ratio in both men and women. Men with lower, more masculine, finger length ratios had higher trait physical aggression scores (r(partial) = -0.21, N = 134, P = 0.028). We found no correlation between finger length ratio and any form of aggression in females. These results are consistent with the hypothesis that testosterone has an organizational effect on adult physical aggression in men.

  12. Design of a Variable Stiffness Soft Dexterous Gripper

    PubMed Central

    Nefti-Meziani, Samia; Davis, Steve

    2017-01-01

    Abstract This article presents the design of a variable stiffness, soft, three-fingered dexterous gripper. The gripper uses two designs of McKibben muscles. Extensor muscles that increase in length when pressurized are used to form the fingers of the gripper. Contractor muscles that decrease in length when pressurized are then used to apply forces to the fingers through tendons, which cause flexion and extension of the fingers. The two types of muscles are arranged to act antagonistically and this means that by raising the pressure in all of the pneumatic muscles, the stiffness of the system can be increased without a resulting change in finger position. The article presents the design of the gripper, some basic kinematics to describe its function, and then experimental results demonstrating the ability to adjust the bending stiffness of the gripper's fingers. It has been demonstrated that the fingers' bending stiffness can be increased by more than 150%. The article concludes by demonstrating that the fingers can be closed loop position controlled and are able to track step and sinusoidal inputs. PMID:29062630

  13. Finger millet (Ragi, Eleusine coracana L.): a review of its nutritional properties, processing, and plausible health benefits.

    PubMed

    Shobana, S; Krishnaswamy, K; Sudha, V; Malleshi, N G; Anjana, R M; Palaniappan, L; Mohan, V

    2013-01-01

    Finger millet or ragi is one of the ancient millets in India (2300 BC), and this review focuses on its antiquity, consumption, nutrient composition, processing, and health benefits. Of all the cereals and millets, finger millet has the highest amount of calcium (344mg%) and potassium (408mg%). It has higher dietary fiber, minerals, and sulfur containing amino acids compared to white rice, the current major staple in India. Despite finger millet's rich nutrient profile, recent studies indicate lower consumption of millets in general by urban Indians. Finger millet is processed by milling, malting, fermentation, popping, and decortication. Noodles, vermicilli, pasta, Indian sweet (halwa) mixes, papads, soups, and bakery products from finger millet are also emerging. In vitro and in vivo (animal) studies indicated the blood glucose lowering, cholesterol lowering, antiulcerative, wound healing properties, etc., of finger millet. However, appropriate intervention or randomized clinical trials are lacking on these health effects. Glycemic index (GI) studies on finger millet preparations indicate low to high values, but most of the studies were conducted with outdated methodology. Hence, appropriate GI testing of finger millet preparations and short- and long-term human intervention trials may be helpful to establish evidence-based health benefits. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. Finger impedance evaluation by means of hand exoskeleton.

    PubMed

    Fiorilla, Angelo Emanuele; Nori, Francesco; Masia, Lorenzo; Sandini, Giulio

    2011-12-01

    Modulation of arm mechanical impedance is a fundamental aspect for interaction with the external environment and its regulation is essential for stability preservation during manipulation. Even though past research on human arm movements has suggested that models of human finger impedance would benefit the study of neural control mechanisms and the design of novel hand prostheses, relatively few studies have focused on finger and hand impedance. This article touches on the two main aspects of this research topic: first it introduces a mechanical refinement of a device that can be used to effectively measure finger impedance during manipulation tasks; then, it describes a pilot study aimed at identifying the inertia of the finger and the viscous and elastic properties of finger muscles. The proposed wearable exoskeleton, which has been designed to measure finger posture and impedance modulation while leaving the palm free, is capable of applying fast displacements while monitoring the interaction forces between the human finger and the robotic links. Moreover, due to the relatively small inertia of the fingers, it allows us to meet some stringent specifications, performing relatively large displacements (~45°) before the stretch reflex intervenes (~25 ms). The results of measurements on five subjects show that inertia, damping, and stiffness can be effectively identified and that the parameters obtained are comparable with values from previous studies.

  15. Comparative functional MRI study to assess brain activation upon active and passive finger movements in patients with cerebral infarction.

    PubMed

    Fu, Yue; Zhang, Quan; Zhang, Jing; Zhang, Yun Ting

    2015-01-01

    To compare the effects of active and passive movements on brain activation in patients with cerebral infarction using fMRI. Twenty-four hemiplegic patients with cerebral infarction were evaluated using fMRI. All patients performed active and passive finger opposition movements. Patients were instructed to perform the finger opposition movement for the active movement task. For the passive movement task, the subject's fingers were moved by the examiner to perform the finger opposition movement. Statistical parametric mapping software was used for statistical analyses and to process all data. In the affected hemisphere, sensorimotor cortex (SMC) activation intensity and range were significantly stronger during the passive movement of the affected fingers compared to the active movement of the affected fingers (p < 0.05). However, there were no significant differences between active and passive movements of unaffected fingers in SMC activation intensity and range in the unaffected hemisphere (p > 0.05). In addition, the passive movement activated many other regions of the brain. The brain regions activated by passive movements of the affected fingers tended to center toward the contralateral SMC. Our findings suggest that passive movements induce cortical reorganization in patients with cerebral infarction. Therefore, passive movement is likely beneficial for motor function recovery in patients with cerebral infarction.

  16. Prevalence of self-reported finger deformations and occupational risk factors among professional cooks: a cross-sectional study.

    PubMed

    Nagasu, Miwako; Sakai, Kazuhiro; Kogi, Kazutaka; Ito, Akiyoshi; Feskens, Edith J M; Tomita, Shigeru; Temmyo, Yoshiomi; Ueno, Mitsuo; Miyagi, Shigeji

    2011-05-26

    Previous studies have pointed out that the school lunch workers in Japan are suffering from work-related disorders including finger deformations. The purpose of this study was to investigate the prevalence of self-reported finger deformations and the association with job-related risk factors. A cross-sectional questionnaire study of 5,719 subjects (response rate: 81%, 982 men and 4,737 women) was undertaken during September 2003 to February 2004. Finger deformations were found among 11.7% of the men and 35.6% of the women studied, with significant differences among sex, age and sex-age groups. For both men and women the pattern of finger deformations across the hand was similar for the right and the left hand. For women, the deformations were found in about 10% of the distal interphalangeal joints of all fingers. Based on multiple logistic regression analyses, the factors female sex, age, the number of cooked lunches per cook and cooking activities were independently associated with the prevalence of finger deformations. High prevalence odds ratios were found for those frequently carrying or using tools by hands such as delivering containers, distributing meals, preparing dishes, washing equipment, cutting and stirring foods. Among the school lunch workers studied, women had a higher prevalence of finger deformations on all joints of both hands. Various cooking tasks were associated with the prevalence of finger deformations. The results suggest that improvements in working conditions are important for preventing work-related disorders such as finger deformations.

  17. Is the thumb a fifth finger? A study of digit interaction during force production tasks

    PubMed Central

    Olafsdottir, Halla; Zatsiorsky, Vladimir M.; Latash, Mark L.

    2010-01-01

    We studied indices of digit interaction in single- and multi-digit maximal voluntary contraction (MVC) tests when the thumb acted either in parallel or in opposition to the fingers. The peak force produced by the thumb was much higher when the thumb acted in opposition to the fingers and its share of the total force in the five-digit MVC test increased dramatically. The fingers showed relatively similar peak forces and unchanged sharing patterns in the four-finger MVC task when the thumb acted in parallel and in opposition to the fingers. Enslaving during one-digit tasks showed relatively mild differences between the two conditions, while the differences became large when enslaving was quantified for multi-digit tasks. Force deficit was pronounced when the thumb acted in parallel to the fingers; it showed a monotonic increase with the number of explicitly involved digits up to four digits and then a drop when all five digits were involved. Force deficit all but disappeared when the thumb acted in opposition to the fingers. However, for both thumb positions, indices of digit interaction were similar for groups of digits that did or did not include the thumb. These results suggest that, given a certain hand configuration, the central nervous system treats the thumb as a fifth finger. They provide strong support for the hypothesis that indices of digit interaction reflect neural factors, not the peripheral design of the hand. An earlier formal model was able to account for the data when the thumb acted in parallel to the fingers. However, it failed for the data with the thumb acting in opposition to the fingers. PMID:15322785

  18. Multi-Finger Interaction and Synergies in Finger Flexion and Extension Force Production

    PubMed Central

    Park, Jaebum; Xu, Dayuan

    2017-01-01

    The aim of this study was to discover finger interaction indices during single-finger ramp tasks and multi-finger coordination during a steady state force production in two directions, flexion, and extension. Furthermore, the indices of anticipatory adjustment of elemental variables (i.e., finger forces) prior to a quick pulse force production were quantified. It is currently unknown whether the organization and anticipatory modulation of stability properties are affected by force directions and strengths of in multi-finger actions. We expected to observe a smaller finger independency and larger indices of multi-finger coordination during extension than during flexion due to both neural and peripheral differences between the finger flexion and extension actions. We also examined the indices of the anticipatory adjustment between different force direction conditions. The anticipatory adjustment could be a neural process, which may be affected by the properties of the muscles and by the direction of the motions. The maximal voluntary contraction (MVC) force was larger for flexion than for extension, which confirmed the fact that the strength of finger flexor muscles (e.g., flexor digitorum profundus) was larger than that of finger extensor (e.g., extensor digitorum). The analysis within the uncontrolled manifold (UCM) hypothesis was used to quantify the motor synergy of elemental variables by decomposing two sources of variances across repetitive trials, which identifies the variances in the uncontrolled manifold (VUCM) and that are orthogonal to the UCM (VORT). The presence of motor synergy and its strength were quantified by the relative amount of VUCM and VORT. The strength of motor synergies at the steady state was larger in the extension condition, which suggests that the stability property (i.e., multi-finger synergies) may be a direction specific quantity. However, the results for the existence of anticipatory adjustment; however, no difference between the directional conditions suggests that feed-forward synergy adjustment (changes in the stability property) may be at least independent of the magnitude of the task-specific apparent performance variables and its direction (e.g., flexion and extension forces). PMID:28674489

  19. Wire perturbations in the Staffman-Taylor problem

    NASA Technical Reports Server (NTRS)

    Hong, D. C.

    1988-01-01

    Zocchi et al. (1987) discovered that when two wires are symmetrically placed along the center of a Hele-Shaw cell, symmetric but narrow fingers of dimensionless width lambda less than 0.5 develop. The value of lambda decreases as the pushing velocity increases, but at a certain critical finger width the finger suddenly undergoes a transition to the asymmetrical state. A simple theory to predict this critical finger width as a function of D, the dimensionless distance between two wires is developed by assuming that the finger opens up a negative angle at the contact point.

  20. Building intelligent communication systems for handicapped aphasiacs.

    PubMed

    Fu, Yu-Fen; Ho, Cheng-Seen

    2010-01-01

    This paper presents an intelligent system allowing handicapped aphasiacs to perform basic communication tasks. It has the following three key features: (1) A 6-sensor data glove measures the finger gestures of a patient in terms of the bending degrees of his fingers. (2) A finger language recognition subsystem recognizes language components from the finger gestures. It employs multiple regression analysis to automatically extract proper finger features so that the recognition model can be fast and correctly constructed by a radial basis function neural network. (3) A coordinate-indexed virtual keyboard allows the users to directly access the letters on the keyboard at a practical speed. The system serves as a viable tool for natural and affordable communication for handicapped aphasiacs through continuous finger language input.

  1. Response to reflected-force feedback to fingers in teleoperations

    NASA Technical Reports Server (NTRS)

    Sutter, P. H.; Iatridis, J. C.; Thakor, N. V.

    1989-01-01

    Reflected-force feedback is an important aspect of teleoperations. The objective is to determine the ability of the human operator to respond to that force. Telerobotics operation is simulated by computer control of a motor-driven device with capabilities for programmable force feedback and force measurement. A computer-controlled motor drive is developed that provides forces against the fingers as well as (angular) position control. A load cell moves in a circular arc as it is pushed by a finger and measures reaction forces on the finger. The force exerted by the finger on the load cell and the angular position are digitized and recorded as a function of time by the computer. Flexure forces of the index, long and ring fingers of the human hand in opposition to the motor driven load cell are investigated. Results of the following experiments are presented: (1) Exertion of maximum finger force as a function of angle; (2) Exertion of target finger force against a computer controlled force; and (3) Test of the ability to move to a target force against a force that is a function of position. Averaged over ten individuals, the maximum force that could be exerted by the index or long finger is about 50 Newtons, while that of the ring finger is about 40 Newtons. From the tests of the ability of a subject to exert a target force, it was concluded that reflected-force feedback can be achieved with the direct kinesthetic perception of force without the use of tactile or visual clues.

  2. Outcomes of percutaneous trigger finger release with concurrent steroid injection.

    PubMed

    Liu, Wen-Chih; Lu, Chun-Kuan; Lin, Yu-Chuan; Huang, Peng-Ju; Lin, Gau-Tyan; Fu, Yin-Chih

    2016-12-01

    Percutaneous release (PR) of the A1 pulley is a quick, safe, and minimally invasive procedure for treating trigger fingers. The purpose of this study is to identify if PR with additional steroid injections can shorten the recovery to reach unlimited range of motion. Between January 2013 and December 2013, we included 432 trigger fingers with actively correctable triggering or severer symptoms without previous surgical release or steroid injections from two hand clinic offices (A and B). The same experienced surgeon performed PR at the office. Patients from Clinic A received PR with steroid injections and those from Clinic B received PR without steroid injections. Patients returned for follow-up 1 week, 6 weeks, and 12 weeks after the procedure. Between the steroid group and the nonsteroid group, there is no significant difference in the mean time for patients to return to normal work and the rate of residual extensor lag. Middle fingers showed a 5.09-fold chance of having a residual extensor lag over that of the other fingers. High grade trigger fingers recovered more slowly than low grade ones. The success rate of a 12-week follow-up was 98.4%. There was no significant difference between the steroid group (97.5%) and the nonsteroid group (99.1%). PR can treat trigger fingers effectively, but additional steroid injection does not provide more benefit. Some fingers showed temporary extensor lag, especially in middle fingers and high grade trigger fingers, but 85% of those will eventually reach full recovery after self-rehabilitation without another surgical release. Copyright © 2016. Published by Elsevier Taiwan.

  3. Kinematic evaluation of the finger's interphalangeal joints coupling mechanism--variability, flexion-extension differences, triggers, locking swanneck deformities, anthropometric correlations.

    PubMed

    Leijnse, J N A L; Quesada, P M; Spoor, C W

    2010-08-26

    The human finger contains tendon/ligament mechanisms essential for proper control. One mechanism couples the movements of the interphalangeal joints when the (unloaded) finger is flexed with active deep flexor. This study's aim was to accurately determine in a large finger sample the kinematics and variability of the coupled interphalangeal joint motions, for potential clinical and finger model validation applications. The data could also be applied to humanoid robotic hands. Sixty-eight fingers were measured in seventeen hands in nine subjects. Fingers exhibited great joint mobility variability, with passive proximal interphalangeal hyperextension ranging from zero to almost fifty degrees. Increased measurement accuracy was obtained by using marker frames to amplify finger segment motions. Gravitational forces on the marker frames were not found to invalidate measurements. The recorded interphalangeal joint trajectories were highly consistent, demonstrating the underlying coupling mechanism. The increased accuracy and large sample size allowed for evaluation of detailed trajectory variability, systematic differences between flexion and extension trajectories, and three trigger types, distinct from flexor tendon triggers, involving initial flexion deficits in either proximal or distal interphalangeal joint. The experimental methods, data and analysis should advance insight into normal and pathological finger biomechanics (e.g., swanneck deformities), and could help improve clinical differential diagnostics of trigger finger causes. The marker frame measuring method may be useful to quantify interphalangeal joints trajectories in surgical/rehabilitative outcome studies. The data as a whole provide the most comprehensive collection of interphalangeal joint trajectories for clinical reference and model validation known to us to date. 2010 Elsevier Ltd. All rights reserved.

  4. Treatment of soft-tissue loss with nerve defect in the finger using the boomerang nerve flap.

    PubMed

    Chen, Chao; Tang, Peifu; Zhang, Xu

    2013-01-01

    This study reports simultaneous repair of soft-tissue loss and proper digital nerve defect in the finger using a boomerang nerve flap including nerve graft from the dorsal branch of the proper digital nerve. From July of 2007 to May of 2010, the flap was used in 17 fingers in 17 patients. The injured fingers included five index, seven long, and five ring fingers. The mean soft-tissue loss was 2.5 × 1.9 cm. The mean flap size was 2.8 × 2.1 cm. Proper digital nerve defects were reconstructed using nerve graft harvested from the dorsal branch of the adjacent finger's proper digital nerve. The average nerve graft length was 2.5 cm. The comparison group included 32 patients treated using a cross-finger flap and a secondary free nerve graft. In the study group, 15 flaps survived completely. Partial necrosis at the distal edge of the flap occurred in two cases. At a mean follow-up of 22 months, the average static two-point discrimination and Semmes-Weinstein monofilament test results on the pulp of the reconstructed finger were 7.5 mm and 3.86, respectively. In the comparison group, the results were 9.3 mm and 3.91, respectively. The study group presented better discriminatory sensation on the pulp and milder pain and cold intolerance in the reconstructed finger. The boomerang nerve flap is useful and reliable for reconstructing complicated finger damage involving soft-tissue loss and nerve defect, especially in difficult anatomical regions. Therapeutic, II.

  5. Estimation of Saxophone Control Parameters by Convex Optimization.

    PubMed

    Wang, Cheng-I; Smyth, Tamara; Lipton, Zachary C

    2014-12-01

    In this work, an approach to jointly estimating the tone hole configuration (fingering) and reed model parameters of a saxophone is presented. The problem isn't one of merely estimating pitch as one applied fingering can be used to produce several different pitches by bugling or overblowing. Nor can a fingering be estimated solely by the spectral envelope of the produced sound (as it might for estimation of vocal tract shape in speech) since one fingering can produce markedly different spectral envelopes depending on the player's embouchure and control of the reed. The problem is therefore addressed by jointly estimating both the reed (source) parameters and the fingering (filter) of a saxophone model using convex optimization and 1) a bank of filter frequency responses derived from measurement of the saxophone configured with all possible fingerings and 2) sample recordings of notes produced using all possible fingerings, played with different overblowing, dynamics and timbre. The saxophone model couples one of several possible frequency response pairs (corresponding to the applied fingering), and a quasi-static reed model generating input pressure at the mouthpiece, with control parameters being blowing pressure and reed stiffness. Applied fingering and reed parameters are estimated for a given recording by formalizing a minimization problem, where the cost function is the error between the recording and the synthesized sound produced by the model having incremental parameter values for blowing pressure and reed stiffness. The minimization problem is nonlinear and not differentiable and is made solvable using convex optimization. The performance of the fingering identification is evaluated with better accuracy than previous reported value.

  6. Assessment of two alternative standardised tests for the vascular component of the hand-arm vibration syndrome (HAVS).

    PubMed

    Ye, Ying; Griffin, Michael J

    2016-10-01

    Vibration-induced white finger (VWF) is the vascular component of the hand-arm vibration syndrome (HAVS). Two tests have been standardised so as to assist the diagnosis of VWF: the measurement of finger rewarming times and the measurement of finger systolic blood pressures (FSBPs). This study investigates whether the two tests distinguish between fingers with and without symptoms of whiteness and compares individual results between the two test methods. In 60 men reporting symptoms of the HAVS, the times for their fingers to rewarm by 4°C (after immersion in 15°C water for 5 min) and FSBPs at 30°C, 15°C and 10°C were measured on the same day. There were significant increases in finger rewarming times and significant reductions in FSBPs at both 15°C and 10°C in fingers reported to suffer blanching. The FSBPs had sensitivities and specificities >90%, whereas the finger rewarming test had a sensitivity of 77% and a specificity of 79%. Fingers having longer rewarming times had lower FSBPs at both temperatures. The findings suggest that, when the test conditions are controlled according to the relevant standard, finger rewarming times and FSBPs can provide useful information for the diagnosis of VWF, although FSBPs are more sensitive and more specific. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  7. Effect of mechanical forces on finger nail curvature: an analysis of the effect of occupation on finger nails.

    PubMed

    Sano, Hitomi; Shionoya, Kaori; Ogawa, Rei

    2014-04-01

    We studied the relationship between mechanical force and nail curvature. The effect of different frequencies and strengths of mechanical force on nail curvature was assessed. In Study 1, 63 carpenters and 63 office workers were enrolled, and the configurations of their thumb nails were assessed by measuring the curve index (defined as nail height/width) and pinch strength. In Study 2, nail curvature and pinch strength of jazz bassists, who characteristically do not use the right fourth and fifth fingers but use the left fifth finger a lot, were compared. In Study 3, the thumb nail curvature and pinch strength of the dominant and nondominant sides of the 126 participants from Study 1 were compared. Study 1: Carpenters had a significantly lower mean thumb nail curve index and higher mean pinch strength. Study 2: The nails of the unused right fourth and fifth fingers were much more curved than the nails of the frequently used left fourth and fifth fingers. The pinch strength of the right fifth finger was much weaker than the pinch strength of the left fifth finger. Study 3: The dominant side had a significantly lower nail curve index and higher pinch strength. The frequency and strength of mechanical forces on finger nails significantly affect nail appearance. © 2014 by the American Society for Dermatologic Surgery, Inc. Published by Wiley Periodicals, Inc.

  8. Workplace accident-related finger-fracture at the Mexican Institute of Social Security. Resolution time, economic impact and sequelae.

    PubMed

    Salinas-Tovar, Santiago; Hernández-Leyva, Blanca E; Marín-Cotoñieto, Irma Araceli; Santos-Celis, Rafael; Luna-Pizarro, Daniel; López-Rojas, Pablo

    2007-01-01

    To identify resolution time and economic impact of occupational finger fracture with permanent disability. A cross-sectional study was conducted in 2004; the main variables were age; sex; disability days and sequelae. The International Classification of Diseases (ICD 10) was used for the study. The analysis included frequency, exceeded disability days and estimation of cost of disabilities, pensions and direct costs. Chi square test was used to identify the differences. 13,410 Fractures occurred nationwide: multiple finger fractures (803); thumb fractures (1982) and other finger fractures (10,625). Days of resolution time were: 70.5 days for multiple finger fractures and 51.1 days for another finger fractures. Permanent disability partial rate of thumb fracture was 5.3/100, 15.8/100 multiple finger fractures and 5.9 fractures of other finger. The estimated cost by temporary disability in the Instituto Mexicano del Seguro Social was on $10,669,000 U.S., while permanent disability costs in cases of settlements and annual pension payments were $758,536 U.S. Finger-fracture is a prevalent pathology whichever needs that medical procedures are review, also identify factors that decrease resolution time and establish improve actions that create boundaries on the workers damage health. It must be considered that this condition affects enterprise' productivity and decrease the quality of life from workers.

  9. Finger-tapping motion analysis in cervical myelopathy by magnetic-sensor tapping device.

    PubMed

    Miwa, Toshitada; Hosono, Noboru; Mukai, Yoshihiro; Makino, Takahiro; Kandori, Akihiko; Fuji, Takeshi

    2013-08-01

    Case-control study. The purpose of this study is to determine finger motion of patients with cervical myelopathy during finger-tapping cycles. A major symptom of patients with compressive cervical myelopathy is finger clumsiness. Therefore, understanding finger motion is prerequisite in assessing the severity of myelopathy. The popular grip-and-release test evaluates only the number of motion cycles, which is insufficient to fully describe complex finger motion. Forty-three patients with cervical myelopathy and 41 healthy controls tapped their index fingers against their thumbs as rapidly as possible for 30 seconds and the motion was recorded by a magnetic-sensor coil attached to the nail surface. Output signals were stored in a computer, which automatically calculated tapping frequency, distance moved, ratio of opening/closing velocity and the SD of the tapping interval. The SD of the tapping interval was significantly greater and all other measures were significantly smaller in patients with cervical myelopathy, than in healthy controls. All indices significantly improved after surgical decompression of the cervical spine. Distance moved (Pearson correlation coefficient: r=0.590, P<0.001) and the SD of the tapping interval (r=-0.451; P=0.002) were significantly correlated with the Japanese Orthopedic Association score (neurological scale). The quantitative evaluation of finger paralysis was performed by this tapping device. Speed and regularity in repetitive motion of fingers were correlated with the severity of cervical myelopathy.

  10. [Necrosis in fingers and toes following local anaesthesia with adrenaline--an urban legend?].

    PubMed

    Finsen, Vilhjalmur

    2013-09-17

    It is often maintained that a local anaesthetic (usually lidocaine) with adrenaline must not be used in fingers and toes because it may cause necrosis due to vascular spasm in end arteries. This review article is an attempt to find evidence to support this warning. Relevant literature was found by means of searches in PubMed limited downwards to 1946 and in EMBASE from 1980 to 2012, and in reference lists. Five review articles on finger necrosis following local anaesthesia concluded that lidocaine with adrenaline does not entail a risk of ischaemic injury. One article found 48 reported cases of finger necrosis in the period 1880 to 2000. Most were from the first half of the 1900s, and none involved lidocaine. Gangrene of part of the finger tip has subsequently been described in one patient with Raynaud's syndrome. No cases of necrosis have been described in a large number of reported accidents in which EpiPen injections contained the same quantity of adrenaline as is found in 60 ml lidocaine with adrenaline. Over a quarter of a million reports have been made of operations on feet, hands, fingers and toes anaesthetised with lidocaine with adrenaline without resulting necrosis. There are no grounds for the warning against using lidocaine with adrenaline in fingers and toes. This anaesthetic offers considerable practical advantages. Care should be taken with infected fingers or fingers with poor circulation.

  11. Neuron selection based on deflection coefficient maximization for the neural decoding of dexterous finger movements.

    PubMed

    Kim, Yong-Hee; Thakor, Nitish V; Schieber, Marc H; Kim, Hyoung-Nam

    2015-05-01

    Future generations of brain-machine interface (BMI) will require more dexterous motion control such as hand and finger movements. Since a population of neurons in the primary motor cortex (M1) area is correlated with finger movements, neural activities recorded in M1 area are used to reconstruct an intended finger movement. In a BMI system, decoding discrete finger movements from a large number of input neurons does not guarantee a higher decoding accuracy in spite of the increase in computational burden. Hence, we hypothesize that selecting neurons important for coding dexterous flexion/extension of finger movements would improve the BMI performance. In this paper, two metrics are presented to quantitatively measure the importance of each neuron based on Bayes risk minimization and deflection coefficient maximization in a statistical decision problem. Since motor cortical neurons are active with movements of several different fingers, the proposed method is more suitable for a discrete decoding of flexion-extension finger movements than the previous methods for decoding reaching movements. In particular, the proposed metrics yielded high decoding accuracies across all subjects and also in the case of including six combined two-finger movements. While our data acquisition and analysis was done off-line and post processing, our results point to the significance of highly coding neurons in improving BMI performance.

  12. Neuron Selection Based on Deflection Coefficient Maximization for the Neural Decoding of Dexterous Finger Movements

    PubMed Central

    Kim, Yong-Hee; Thakor, Nitish V.; Schieber, Marc H.; Kim, Hyoung-Nam

    2015-01-01

    Future generations of brain-machine interface (BMI) will require more dexterous motion control such as hand and finger movements. Since a population of neurons in the primary motor cortex (M1) area is correlated with finger movements, neural activities recorded in M1 area are used to reconstruct an intended finger movement. In a BMI system, decoding discrete finger movements from a large number of input neurons does not guarantee a higher decoding accuracy in spite of the increase in computational burden. Hence, we hypothesize that selecting neurons important for coding dexterous flexion/extension of finger movements would improve the BMI performance. In this paper, two metrics are presented to quantitatively measure the importance of each neuron based on Bayes risk minimization and deflection coefficient maximization in a statistical decision problem. Since motor cortical neurons are active with movements of several different fingers, the proposed method is more suitable for a discrete decoding of flexion-extension finger movements than the previous methods for decoding reaching movements. In particular, the proposed metrics yielded high decoding accuracies across all subjects and also in the case of including six combined two-finger movements. While our data acquisition and analysis was done off-line and post processing, our results point to the significance of highly coding neurons in improving BMI performance. PMID:25347884

  13. The effects of human finger and Chinese character on Chinese handwriting performance on mobile touch devices.

    PubMed

    Chen, Zhe; Rau, Pei-Luen Patrick; Chen, Cuiling

    2014-05-01

    The aim of the present study is to investigate Chinese handwriting on mobile touch devices, considering the effects of three characteristics of the human finger (type, length, and width) and three characteristics of Chinese characters (direction of the first stroke, number of strokes, and structure). Due to the popularity of touch devices in recent years, finger input for Chinese characters has attracted more attention from both industry and academia. However, previous studies have no systematical consideration on the effects of human finger and Chinese characters on Chinese handwriting performance. An experiment was reported in this article to illustrate the effects of the human finger and Chinese characters on the Chinese handwriting performance (i.e., input time, accuracy, number of protruding strokes, mental workload, satisfaction, and physical fatigue). The experiment results indicated that all six factors have significant effects on Chinese handwriting performance, especially on the input time, accuracy, and number of protruding strokes. Finger type, finger length, finger width, direction of the first stroke, number of strokes, and character structures are significantly influencing Chinese handwriting performance. These factors should be taken into more consideration in future research and the practical design for Chinese handwriting systems.

  14. An open-source model and solution method to predict co-contraction in the finger.

    PubMed

    MacIntosh, Alexander R; Keir, Peter J

    2017-10-01

    A novel open-source biomechanical model of the index finger with an electromyography (EMG)-constrained static optimization solution method are developed with the goal of improving co-contraction estimates and providing means to assess tendon tension distribution through the finger. The Intrinsic model has four degrees of freedom and seven muscles (with a 14 component extensor mechanism). A novel plugin developed for the OpenSim modelling software applied the EMG-constrained static optimization solution method. Ten participants performed static pressing in three finger postures and five dynamic free motion tasks. Index finger 3D kinematics, force (5, 15, 30 N), and EMG (4 extrinsic muscles and first dorsal interosseous) were used in the analysis. The Intrinsic model predicted co-contraction increased by 29% during static pressing over the existing model. Further, tendon tension distribution patterns and forces, known to be essential to produce finger action, were determined by the model across all postures. The Intrinsic model and custom solution method improved co-contraction estimates to facilitate force propagation through the finger. These tools improve our interpretation of loads in the finger to develop better rehabilitation and workplace injury risk reduction strategies.

  15. Multiple Fingers - One Gestalt.

    PubMed

    Lezkan, Alexandra; Manuel, Steven G; Colgate, J Edward; Klatzky, Roberta L; Peshkin, Michael A; Drewing, Knut

    2016-01-01

    The Gestalt theory of perception offered principles by which distributed visual sensations are combined into a structured experience ("Gestalt"). We demonstrate conditions whereby haptic sensations at two fingertips are integrated in the perception of a single object. When virtual bumps were presented simultaneously to the right hand's thumb and index finger during lateral arm movements, participants reported perceiving a single bump. A discrimination task measured the bump's perceived location and perceptual reliability (assessed by differential thresholds) for four finger configurations, which varied in their adherence to the Gestalt principles of proximity (small versus large finger separation) and synchrony (virtual spring to link movements of the two fingers versus no spring). According to models of integration, reliability should increase with the degree to which multi-finger cues integrate into a unified percept. Differential thresholds were smaller in the virtual-spring condition (synchrony) than when fingers were unlinked. Additionally, in the condition with reduced synchrony, greater proximity led to lower differential thresholds. Thus, with greater adherence to Gestalt principles, thresholds approached values predicted for optimal integration. We conclude that the Gestalt principles of synchrony and proximity apply to haptic perception of surface properties and that these principles can interact to promote multi-finger integration.

  16. Ergonomics Designs of Aluminum Beverage Cans and Bottles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Han Jing; Itoh, Ryouiti; Shinguryo, Takuro

    2005-08-05

    This paper introduced the finite element analyses into the ergonomics designs to evaluate the human feelings numerically and objectively. Two design examples in developing aluminum beverage cans and bottles are presented. The first example describes a design of the tab of the can with better finger access. A simulation of finger pulling up the tab of the can has been performed and a pain in the finger has been evaluated by using the maximum value of the contact stress of a finger model. The finger access comparison of three kinds of tab ring shape designs showed that the finger accessmore » of the tab that may have a larger contact area with finger is better. The second example describes a design of rib-shape embossed bottles for hot vending. Analyses of tactile sensation of heat have been performed and the amount of heat transmitted from hot bottles to finger was used to present the hot touch feeling. Comparison results showed that the hot touch feeling of rib-shape embossed bottles is better than that of cylindrical bottles, and that the shape of the rib also influenced the hot touch feeling.« less

  17. The inheritance of fingerprint patterns.

    PubMed

    Slatis, H M; Katznelson, M B; Bonné-Tamir, B

    1976-05-01

    Analysis of the fingerprints of 571 members of the Habbanite isolate suggest inherited patterns and pattern sequences. A genetic theory has been developed; it assumes that the basic fingerprint pattern sequence is all ulnar loops and that a variety of genes cause deviations from this pattern sequence. Genes that have been proposed include: (1) a semidominant gene for whorls on the thumbs (one homozygote has whorls on both thumbs, the other has ulnar loops on both thumbs and the heterozygote usually has two ulnar loops or one ulnar loop and one whorl); (2) a semidominant gene for whorls on the ring fingers which acts like the gene for whorls on the thumbs; (3) a dominant gene for arches on the thumbs and often on other fingers; (4) one or more dominant genes for arches on the fingers; (5) a dominant gene for whorls on all fingers except for an ulnar loop on the middle finger; (6) a dominant gene for radial loops on the index fingers, frequently associated with an arch on the middle fingers; and (7) a recessive gene for radial loops on the ring and little fingers. These genes may act independently or may show epistasis.

  18. The inheritance of fingerprint patterns.

    PubMed Central

    Slatis, H M; Katznelson, M B; Bonné-Tamir, B

    1976-01-01

    Analysis of the fingerprints of 571 members of the Habbanite isolate suggest inherited patterns and pattern sequences. A genetic theory has been developed; it assumes that the basic fingerprint pattern sequence is all ulnar loops and that a variety of genes cause deviations from this pattern sequence. Genes that have been proposed include: (1) a semidominant gene for whorls on the thumbs (one homozygote has whorls on both thumbs, the other has ulnar loops on both thumbs and the heterozygote usually has two ulnar loops or one ulnar loop and one whorl); (2) a semidominant gene for whorls on the ring fingers which acts like the gene for whorls on the thumbs; (3) a dominant gene for arches on the thumbs and often on other fingers; (4) one or more dominant genes for arches on the fingers; (5) a dominant gene for whorls on all fingers except for an ulnar loop on the middle finger; (6) a dominant gene for radial loops on the index fingers, frequently associated with an arch on the middle fingers; and (7) a recessive gene for radial loops on the ring and little fingers. These genes may act independently or may show epistasis. PMID:1266855

  19. Management of the Stiff Finger: Evidence and Outcomes

    PubMed Central

    Yang, Guang; McGlinn, Evan P.; Chung, Kevin C.

    2014-01-01

    SYNOPSIS The term “stiff finger” refers to a reduction in the range of motion in the finger, and it is a condition that has many different causes and involves a number of different structures. Almost all injuries of the fingers and some diseases can cause finger stiffness. Hand surgeons often face difficulty treating stiff fingers that are affected by irreversible soft tissues fibrosis. Stiff fingers can be divided into flexion and extension deformities. They can also be sub-classified into four categories according to the involved tissues extending from the skin to the joint capsule. Prevention of stiff fingers by judicious mobilization of the joints is prudent to avoid more complicated treatment after established stiffness occurs. Static progressive and dynamic splints have been considered as effective non-operative interventions to treat stiff fingers. Most authors believe force of joint distraction and time duration of stretching are two important factors to consider while applying a splint or cast. We also introduce the concepts of capsulotomy and collateral ligament release and other soft tissue release of the MCP and PIP joint in this article. Future outcomes research is vital to assessing the effectiveness of these surgical procedures and guiding postoperative treatment recommendations. PMID:24996467

  20. Steam trap monitor

    DOEpatents

    Ryan, Michael J.

    1988-01-01

    A steam trap monitor positioned downstream of a steam trap in a closed steam system includes a first sensor (the combination of a hot finger and thermocouple well) for measuring the energy of condensate and a second sensor (a cold finger) for measuring the total energy of condensate and steam in the line. The hot finger includes one or more thermocouples for detecting condensate level and energy, while the cold finger contains a liquid with a lower boiling temperature than that of water. Vapor pressure from the liquid is used to do work such as displacing a piston or bellows in providing an indication of total energy (steam+condensate) of the system. Processing means coupled to and responsive to outputs from the thermocouple well hot and cold fingers subtracts the condensate energy as measured by the hot finger and thermocouple well from the total energy as measured by the cold finger to provide an indication of the presence of steam downstream from the trap indicating that the steam trap is malfunctioning.

  1. Know thyself: behavioral evidence for a structural representation of the human body.

    PubMed

    Rusconi, Elena; Gonzaga, Mirandola; Adriani, Michela; Braun, Christoph; Haggard, Patrick

    2009-01-01

    Representing one's own body is often viewed as a basic form of self-awareness. However, little is known about structural representations of the body in the brain. We developed an inter-manual version of the classical "in-between" finger gnosis task: participants judged whether the number of untouched fingers between two touched fingers was the same on both hands, or different. We thereby dissociated structural knowledge about fingers, specifying their order and relative position within a hand, from tactile sensory codes. Judgments following stimulation on homologous fingers were consistently more accurate than trials with no or partial homology. Further experiments showed that structural representations are more enduring than purely sensory codes, are used even when number of fingers is irrelevant to the task, and moreover involve an allocentric representation of finger order, independent of hand posture. Our results suggest the existence of an allocentric representation of body structure at higher stages of the somatosensory processing pathway, in addition to primary sensory representation.

  2. Know Thyself: Behavioral Evidence for a Structural Representation of the Human Body

    PubMed Central

    Rusconi, Elena; Gonzaga, Mirandola; Adriani, Michela; Braun, Christoph; Haggard, Patrick

    2009-01-01

    Background Representing one's own body is often viewed as a basic form of self-awareness. However, little is known about structural representations of the body in the brain. Methods and Findings We developed an inter-manual version of the classical “in-between” finger gnosis task: participants judged whether the number of untouched fingers between two touched fingers was the same on both hands, or different. We thereby dissociated structural knowledge about fingers, specifying their order and relative position within a hand, from tactile sensory codes. Judgments following stimulation on homologous fingers were consistently more accurate than trials with no or partial homology. Further experiments showed that structural representations are more enduring than purely sensory codes, are used even when number of fingers is irrelevant to the task, and moreover involve an allocentric representation of finger order, independent of hand posture. Conclusions Our results suggest the existence of an allocentric representation of body structure at higher stages of the somatosensory processing pathway, in addition to primary sensory representation. PMID:19412538

  3. The kinetics and acoustics of fingering and note transitions on the flute.

    PubMed

    Almeida, André; Chow, Renee; Smith, John; Wolfe, Joe

    2009-09-01

    Motion of the keys was measured in a transverse flute while beginner, amateur, and professional flutists played a range of exercises. The time taken for a key to open or close was typically 10 ms when pushed by a finger or 16 ms when moved by a spring. Because the opening and closing of keys will never be exactly simultaneous, transitions between notes that involve the movement of multiple fingers can occur via several possible pathways with different intermediate fingerings. A transition is classified as "safe" if it is possible to be slurred from the initial to final note with little perceptible change in pitch or volume. Some transitions are "unsafe" and possibly involve a transient change in pitch or a decrease in volume. Players, on average, used safe transitions more frequently than unsafe transitions. Delays between the motion of the fingers were typically tens of milliseconds, with longer delays as more fingers become involved. Professionals exhibited smaller average delays between the motion of their fingers than did amateurs.

  4. Generation of dense plume fingers in saturated-unsaturated homogeneous porous media

    NASA Astrophysics Data System (ADS)

    Cremer, Clemens J. M.; Graf, Thomas

    2015-02-01

    Flow under variable-density conditions is widespread, occurring in geothermal reservoirs, at waste disposal sites or due to saltwater intrusion. The migration of dense plumes typically results in the formation of vertical plume fingers which are known to be triggered by material heterogeneity or by variations in source concentration that causes the density variation. Using a numerical groundwater model, six perturbation methods are tested under saturated and unsaturated flow conditions to mimic heterogeneity and concentration variations on the pore scale in order to realistically generate dense fingers. A laboratory-scale sand tank experiment is numerically simulated, and the perturbation methods are evaluated by comparing plume fingers obtained from the laboratory experiment with numerically simulated fingers. Dense plume fingering for saturated flow can best be reproduced with a spatially random, time-constant perturbation of the solute source. For unsaturated flow, a spatially and temporally random noise of solute concentration or a random conductivity field adequately simulate plume fingering.

  5. Sequence Discrimination by Alternatively Spliced Isoforms of a DNA Binding Zinc Finger Domain

    NASA Astrophysics Data System (ADS)

    Gogos, Joseph A.; Hsu, Tien; Bolton, Jesse; Kafatos, Fotis C.

    1992-09-01

    Two major developmentally regulated isoforms of the Drosophila chorion transcription factor CF2 differ by an extra zinc finger within the DNA binding domain. The preferred DNA binding sites were determined and are distinguished by an internal duplication of TAT in the site recognized by the isoform with the extra finger. The results are consistent with modular interactions between zinc fingers and trinucleotides and also suggest rules for recognition of AT-rich DNA sites by zinc finger proteins. The results show how modular finger interactions with trinucleotides can be used, in conjunction with alternative splicing, to alter the binding specificity and increase the spectrum of sites recognized by a DNA binding domain. Thus, CF2 may potentially regulate distinct sets of target genes during development.

  6. Single Degree-of-Freedom Exoskeleton Mechanism Design for Finger Rehabilitation

    PubMed Central

    Wolbrecht, Eric T.; Reinkensmeyer, David J.; Perez-Gracia, Alba

    2014-01-01

    This paper presents the kinematic design of a single degree-of-freedom exoskeleton mechanism: a planar eight-bar mechanism for finger curling. The mechanism is part of a finger-thumb robotic device for hand therapy that will allow users to practice key pinch grip and finger-thumb opposition, allowing discrete control inputs for playing notes on a musical gaming interface. This approach uses the mechanism to generate the desired grasping trajectory rather than actuating the joints of the fingers and thumb independently. In addition, the mechanism is confined to the back of the hand, so as to allow sensory input into the palm of the hand, minimal size and apparent inertia, and the possibility of placing multiple mechanisms side-by-side to allow control of individual fingers. PMID:22275628

  7. Finger-Vein Verification Based on Multi-Features Fusion

    PubMed Central

    Qin, Huafeng; Qin, Lan; Xue, Lian; He, Xiping; Yu, Chengbo; Liang, Xinyuan

    2013-01-01

    This paper presents a new scheme to improve the performance of finger-vein identification systems. Firstly, a vein pattern extraction method to extract the finger-vein shape and orientation features is proposed. Secondly, to accommodate the potential local and global variations at the same time, a region-based matching scheme is investigated by employing the Scale Invariant Feature Transform (SIFT) matching method. Finally, the finger-vein shape, orientation and SIFT features are combined to further enhance the performance. The experimental results on databases of 426 and 170 fingers demonstrate the consistent superiority of the proposed approach. PMID:24196433

  8. Noninvasively measuring oxygen saturation of human finger-joint vessels by multi-transducer functional photoacoustic tomography

    NASA Astrophysics Data System (ADS)

    Deng, Zijian; Li, Changhui

    2016-06-01

    Imaging small blood vessels and measuring their functional information in finger joint are still challenges for clinical imaging modalities. In this study, we developed a multi-transducer functional photoacoustic tomography (PAT) system and successfully imaged human finger-joint vessels from ˜1 mm to <0.2 mm in diameter. In addition, the oxygen saturation (SO2) values of these vessels were also measured. Our results demonstrate that PAT can provide both anatomical and functional information of individual finger-joint vessels with different sizes, which might help the study of finger-joint diseases, such as rheumatoid arthritis.

  9. Perception and Haptic Rendering of Friction Moments.

    PubMed

    Kawasaki, H; Ohtuka, Y; Koide, S; Mouri, T

    2011-01-01

    This paper considers moments due to friction forces on the human fingertip. A computational technique called the friction moment arc method is presented. The method computes the static and/or dynamic friction moment independent of a friction force calculation. In addition, a new finger holder to display friction moment is presented. This device incorporates a small brushless motor and disk, and connects the human's finger to an interface finger of the five-fingered haptic interface robot HIRO II. Subjects' perception of friction moment while wearing the finger holder, as well as perceptions during object manipulation in a virtual reality environment, were evaluated experimentally.

  10. Differing roles for zinc fingers in DNA recognition: Structure of a six-finger transcription factor IIIA complex

    PubMed Central

    Nolte, Robert T.; Conlin, Rachel M.; Harrison, Stephen C.; Brown, Raymond S.

    1998-01-01

    The crystal structure of the six NH2-terminal zinc fingers of Xenopus laevis transcription factor IIIA (TFIIIA) bound with 31 bp of the 5S rRNA gene promoter has been determined at 3.1 Å resolution. Individual zinc fingers are positioned differently in the major groove and across the minor groove of DNA to span the entire length of the duplex. These results show how TFIIIA can recognize several separated DNA sequences by using fewer fingers than necessary for continuous winding in the major groove. PMID:9501194

  11. A variational approach to the strongly nonlinear regime of the Rayleigh-Taylor instability

    NASA Astrophysics Data System (ADS)

    Yoshikawa, Toshio

    The Rayleigh-Taylor instability is the instability of the interface between two fluids of different densities. When a heavy fluid is superposed over a light fluid. small disturbances on the interface develop into a complex form with heavy fluid ``fingers'' and light fluid ``bubbles.'' We propose a variational method for the description of the evolution of the fingers and bubbles in the late stage of the instability. In this method, the fluid region is represented as the image of a time-dependent conformal mapping; the dynamics of the mapping is determined by the least action principle for the Lagrangian. i.e., the kinetic energy minus the potential energy. The evolution of a single finger and bubble is investigated by this method. We first consider a symmetric finger and bubble in a zero gravitational field. We derive an integrable Hamiltonian system with two degrees of freedom that governs the dynamics of the symmetric finger and bubble. We present a general solution of the system. The solution predicts the linear growth of the finger and the saturation of the bubble growth. It is shown that this solution is asymptotically exact. We consider a symmetric finger and bubble with perturbations. We show that the dynamics of the finger and bubble and that of the perturbations are decoupled. We next consider an inclined finger and bubble in a zero gravitational field. We derive a Hamiltonian system with four degrees of freedom that governs the dynamics of the inclined finger and bubble. The system has four integrals of motion, one of them depends on time explicitly. When there is no lateral motion, the system reduces to an integrable Hamiltonian system with three degrees of freedom. A general solution of the system is presented. The solution predicts the linear growth of the finger toward a direction and the saturation of the bubble growth. Finally, we consider a symmetric finger and bubble in a uniform gravitational field. We derive a Hamiltonian system with two degrees of freedom that governs the dynamics of the symmetric finger and bubble. Since the system includes a potential energy term, it is not integrable in general. However, we present a general solution in the case of the total energy being zero. This case corresponds to an interesting case where the evolution starts from a flat surface. The solution predicts that the finger grows as the square of time, and the bubble as the square root of time.

  12. The effects of vibration-reducing gloves on finger vibration

    PubMed Central

    Welcome, Daniel E.; Dong, Ren G.; Xu, Xueyan S.; Warren, Christopher; McDowell, Thomas W.

    2015-01-01

    Vibration-reducing (VR) gloves have been used to reduce the hand-transmitted vibration exposures from machines and powered hand tools but their effectiveness remains unclear, especially for finger protection. The objectives of this study are to determine whether VR gloves can attenuate the vibration transmitted to the fingers and to enhance the understanding of the mechanisms of how these gloves work. Seven adult male subjects participated in the experiment. The fixed factors evaluated include hand force (four levels), glove condition (gel-filled, air bladder, no gloves), and location of the finger vibration measurement. A 3-D laser vibrometer was used to measure the vibrations on the fingers with and without wearing a glove on a 3-D hand-arm vibration test system. This study finds that the effect of VR gloves on the finger vibration depends on not only the gloves but also their influence on the distribution of the finger contact stiffness and the grip effort. As a result, the gloves increase the vibration in the fingertip area but marginally reduce the vibration in the proximal area at some frequencies below 100 Hz. On average, the gloves reduce the vibration of the entire fingers by less than 3% at frequencies below 80 Hz but increase at frequencies from 80 to 400 Hz. At higher frequencies, the gel-filled glove is more effective at reducing the finger vibration than the air bladder-filled glove. The implications of these findings are discussed. Relevance to industry Prolonged, intensive exposure to hand-transmitted vibration can cause hand-arm vibration syndrome. Vibration-reducing gloves have been used as an alternative approach to reduce the vibration exposure. However, their effectiveness for reducing finger-transmitted vibrations remains unclear. This study enhanced the understanding of the glove effects on finger vibration and provided useful information on the effectiveness of typical VR gloves at reducing the vibration transmitted to the fingers. The new results and knowledge can be used to help select appropriate gloves for the operations of powered hand tools, to help perform risk assessment of the vibration exposure, and to help design better VR gloves. PMID:26543297

  13. A quiet harvest: linkage between ritual, seed selection and the historical use of the finger-bladed knife as a traditional plant breeding tool in Ifugao, Philippines.

    PubMed

    Murphy, Kevin M

    2017-01-13

    The transverse harvest knife, also commonly called the finger or finger-bladed knife, has been utilized by rice farmers in southeast Asia for many centuries. The finger knife persisted in many traditional cultures long after the introduction of the sickle, a tool which provided farmers with the means to execute a much faster harvest. Several theories in interpretative archaeology have attempted to account for this rejection of more modern technological innovations. These theories, which include community-based social organization ideas and practical reasons for the continued use of the finger knife, are presented in this paper. Here I suggest an alternate theory based on a re-interpretation of existing research and fusion of existing theories: the primary reason for the historical and continued use of the finger knife is for seed selection through a centuries old tradition of plant breeding. Though I accept the accuracy of the practical and community-based, socio-cultural reasons for the use of the finger knife put forth by other authors, I suggest that seed selection and genetic improvement was the driving factor in the use of the finger knife. Indeed, intricate planting and harvesting rituals, which both ensured and encouraged varietal conservation and improvement co-evolved with the use of the finger knife as the primary harvest tool due to its unique ability to aid the farmer in the art and science of seed selection. When combined with previous ideas, this interpretative theory, based on the connection between ethnoagronomy and material culture, may provide a more complete picture of the story around the persistence of the finger knife in traditional rice-growing cultures in southeast Asia. I focus my theory on the terrace-building Ifugao people in the mountainous Cordillera region of northcentral Philippines; however, to put the use of the finger into a wider regional context, I draw from examples of the use of the finger knife in other traditional cultures throughout the region of southeast Asia.

  14. Numerical Generation of Dense Plume Fingers in Unsaturated Homogeneous Porous Media

    NASA Astrophysics Data System (ADS)

    Cremer, C.; Graf, T.

    2012-04-01

    In nature, the migration of dense plumes typically results in the formation of vertical plume fingers. Flow direction in fingers is downwards, which is counterbalanced by upwards flow of less dense fluid between fingers. In heterogeneous media, heterogeneity itself is known to trigger the formation of fingers. In homogeneous media, however, fingers are also created even if all grains had the same diameter. The reason is that pore-scale heterogeneity leading to different flow velocities also exists in homogeneous media due to two effects: (i) Grains of identical size may randomly arrange differently, e.g. forming tetrahedrons, hexahedrons or octahedrons. Each arrangement creates pores of varying diameter, thus resulting in different average flow velocities. (ii) Random variations of solute concentration lead to varying buoyancy effects, thus also resulting in different velocities. As a continuation of previously made efforts to incorporate pore-scale heterogeneity into fully saturated soil such that dense fingers are realistically generated (Cremer and Graf, EGU Assembly, 2011), the current paper extends the research scope from saturated to unsaturated soil. Perturbation methods are evaluated by numerically re-simulating a laboratory-scale experiment of plume transport in homogeneous unsaturated sand (Simmons et al., Transp. Porous Media, 2002). The following 5 methods are being discussed: (i) homogeneous sand, (ii) initial perturbation of solute concentration, (iii) spatially random, time-constant perturbation of solute source, (iv) spatially and temporally random noise of simulated solute concentration, and (v) random K-field that introduces physically insignificant but numerically significant heterogeneity. Results demonstrate that, as opposed to saturated flow, perturbing the solute source will not result in plume fingering. This is because the location of the perturbed source (domain top) and the location of finger generation (groundwater surface) do not coincide. Alternatively, similar to saturated flow, applying either a random concentration noise (iv) or a random K-field (v) generates realistic plume fingering. Future work will focus on the generation mechanisms of plume finger splitting.

  15. Mechanisms of inhibition of zinc-finger transcription factors by selenium compounds ebselen and selenite.

    PubMed

    Larabee, Jason L; Hocker, James R; Hanas, Jay S

    2009-03-01

    The anti-inflammatory selenium compounds, ebselen (2-phenyl-1,2-benzisoselenazol-3[2H]-one) and selenite, were found to alter the DNA binding mechanisms and structures of cysteine-rich zinc-finger transcription factors. As assayed by DNase I protection, DNA binding by TFIIIA (transcription factor IIIA, prototypical Cys(2)His(2) zinc finger protein), was inhibited by micromolar amounts of ebselen. In a gel shift assay, ebselen inhibited the Cys(2)His(2) zinc finger-containing DNA binding domain (DBD) of the NF-kappaB mediated transcription factor Sp1. Ebselen also inhibited DNA binding by the p50 subunit of the pro-inflammatory Cys-containing NF-kappaB transcription factor. Electrospray ionization mass spectrometry (ESI-MS) was utilized to elucidate mechanisms of chemical interaction between ebselen and a zinc-bound Cys(2)His(2) zinc finger polypeptide modeled after the third finger of Sp1 (Sp1-3). Exposing Sp1-3 to micromolar amounts of ebselen resulted in Zn(2+) release from this peptide and the formation of a disulfide bond by oxidation of zinc finger SH groups, the likely mechanism for DNA binding inhibition. Selenite was shown by ESI-MS to also eject zinc from Sp1-3 as well as induce disulfide bond formation through SH oxidation. The selenite-dependent inhibition/oxidation mechanism differed from that of ebselen by inducing the formation of a stable selenotrisulfide bond. Selenite-induced selenotrisulfide formation was dependent upon the structure of the Cys(2)His(2) zinc finger as alteration in the finger structure enhanced this reaction as well as selenite-dependent zinc release. Ebselen and selenite-dependent inhibition/oxidation of Cys-rich zinc finger proteins, with concomitant release of zinc and finger structural changes, points to mechanisms at the atomic and protein level for selenium-induced alterations in Cys-rich proteins, and possible amelioration of certain inflammatory, neurodegenerative, and oncogenic responses.

  16. Surround Inhibition in the Primary Motor Cortex is Task-specifically Modulated in Non-professional Musicians but not in Healthy Controls During Real Piano Playing.

    PubMed

    Márquez, Gonzalo; Keller, Martin; Lundbye-Jensen, Jesper; Taube, Wolfgang

    2018-03-01

    Research has indicated that at the onset of a finger movement, unwanted contractions of adjacent muscles are prevented by inhibiting the cortical areas representing these muscles. This so-called surround inhibition (SI) seems relevant for the performance of selective finger movements but may not be necessary for tasks involving functional coupling between different finger muscles. Therefore, the present study compared SI between isolated finger movement and complex selective finger movements while playing a three-finger sequence on the piano in nine non-professional musicians and 10 untrained control participants. Transcranial magnetic stimulation (TMS) was applied to the contralateral motor cortex to assess SI in the first dorsal interosseous (FDI), abductor pollicis brevis (APB) and abductor digiti minimi (ADM) during the movement preparation and the late phasic phases. The results reveal stronger SI during the preparation phase than during the phasic phase (30.6% vs. 10.7%; P < 0.05) in the isolated-finger condition in both musicians and controls. Results also show higher SI in musicians during the preparation phase of the isolated finger condition compared to the preparation phase of the three-finger sequence (40% vs. 15%; P < 0.05). However, the control group did not show this task-specific modulation of SI (isolated: 25% vs. sequence: 25%; P > 0.05). Thus, musicians were able to modulate SI between conditions whereas control participants revealed constant levels of SI. Therefore, it may be assumed that long-term training as observed in skilled musicians is accompanied by task-specific effects on SI modulation potentially relating to the ability to perform selective and complex finger movements. Copyright © 2018 IBRO. Published by Elsevier Ltd. All rights reserved.

  17. Finger-attachment device for the feedback of gripping and pulling force in a manipulating system for brain tumor resection.

    PubMed

    Chinbe, Hiroyuki; Yoneyama, Takeshi; Watanabe, Tetsuyou; Miyashita, Katsuyoshi; Nakada, Mitsutoshi

    2018-01-01

    Development and evaluation of an effective attachment device for a bilateral brain tumor resection robotic surgery system based on the sensory performance of the human index finger in order to precisely detect gripping- and pulling-force feedback. First, a basic test was conducted to investigate the performance of the human index finger in the gripping- and pulling-force feedback system. Based on the test result, a new finger-attachment device was designed and constructed. Then, discrimination tests were conducted to assess the pulling force and the feedback on the hardness of the gripped material. The results of the basic test show the application of pulling force on the side surface of the finger has an advantage to distinguish the pulling force when the gripping force is applied on the finger-touching surface. Based on this result, a finger-attachment device that applies a gripping force on the finger surface and pulling force on the side surface of the finger was developed. By conducting a discrimination test to assess the hardness of the gripped material, an operator can distinguish whether the gripped material is harder or softer than a normal brain tissue. This will help in confirming whether the gripped material is a tumor. By conducting a discrimination test to assess the pulling force, an operator can distinguish the pulling-force resistance when attempting to pull off the soft material. Pulling-force feedback may help avoid the breaking of blood pipes when they are trapped in the gripper or attached to the gripped tissue. The finger-attachment device that was developed for detecting gripping- and pulling-force feedback may play an important role in the development of future neurosurgery robotic systems for precise and safe resection of brain tumors.

  18. Anatomically ordered tapping interferes more with one-digit addition than two-digit addition: a dual-task fMRI study.

    PubMed

    Soylu, Firat; Newman, Sharlene D

    2016-02-01

    Fingers are used as canonical representations for numbers across cultures. In previous imaging studies, it was shown that arithmetic processing activates neural resources that are known to participate in finger movements. Additionally, in one dual-task study, it was shown that anatomically ordered finger tapping disrupts addition and subtraction more than multiplication, possibly due to a long-lasting effect of early finger counting experiences on the neural correlates and organization of addition and subtraction processes. How arithmetic task difficulty and tapping complexity affect the concurrent performance is still unclear. If early finger counting experiences have bearing on the neural correlates of arithmetic in adults, then one would expect anatomically and non-anatomically ordered tapping to have different interference effects, given that finger counting is usually anatomically ordered. To unravel these issues, we studied how (1) arithmetic task difficulty and (2) the complexity of the finger tapping sequence (anatomical vs. non-anatomical ordering) affect concurrent performance and use of key neural circuits using a mixed block/event-related dual-task fMRI design with adult participants. The results suggest that complexity of the tapping sequence modulates interference on addition, and that one-digit addition (fact retrieval), compared to two-digit addition (calculation), is more affected from anatomically ordered tapping. The region-of-interest analysis showed higher left angular gyrus BOLD response for one-digit compared to two-digit addition, and in no-tapping conditions than dual tapping conditions. The results support a specific association between addition fact retrieval and anatomically ordered finger movements in adults, possibly due to finger counting strategies that deploy anatomically ordered finger movements early in the development.

  19. Modeling of the interaction between grip force and vibration transmissibility of a finger.

    PubMed

    Wu, John Z; Welcome, Daniel E; McDowell, Thomas W; Xu, Xueyan S; Dong, Ren G

    2017-07-01

    It is known that the vibration characteristics of the fingers and hand and the level of grip action interacts when operating a power tool. In the current study, we developed a hybrid finger model to simulate the vibrations of the hand-finger system when gripping a vibrating handle covered with soft materials. The hybrid finger model combines the characteristics of conventional finite element (FE) models, multi-body musculoskeletal models, and lumped mass models. The distal, middle, and proximal finger segments were constructed using FE models, the finger segments were connected via three flexible joint linkages (i.e., distal interphalangeal joint (DIP), proximal interphalangeal joint (PIP), and metacarpophalangeal (MCP) joint), and the MCP joint was connected to the ground and handle via lumped parameter elements. The effects of the active muscle forces were accounted for via the joint moments. The bone, nail, and hard connective tissues were assumed to be linearly elastic whereas the soft tissues, which include the skin and subcutaneous tissues, were considered as hyperelastic and viscoelastic. The general trends of the model predictions agree well with the previous experimental measurements in that the resonant frequency increased from proximal to the middle and to the distal finger segments for the same grip force, that the resonant frequency tends to increase with increasing grip force for the same finger segment, especially for the distal segment, and that the magnitude of vibration transmissibility tends to increase with increasing grip force, especially for the proximal segment. The advantage of the proposed model over the traditional vibration models is that it can predict the local vibration behavior of the finger to a tissue level, while taking into account the effects of the active musculoskeletal force, the effects of the contact conditions on vibrations, the global vibration characteristics. Published by Elsevier Ltd.

  20. Settling-driven gravitational instabilities associated with volcanic clouds: new insights from experimental investigations

    NASA Astrophysics Data System (ADS)

    Scollo, Simona; Bonadonna, Costanza; Manzella, Irene

    2017-06-01

    Downward propagating instabilities are often observed at the bottom of volcanic plumes and clouds. These instabilities generate fingers that enhance the sedimentation of fine ash. Despite their potential influence on tephra dispersal and deposition, their dynamics is not entirely understood, undermining the accuracy of volcanic ash transport and dispersal models. Here, we present new laboratory experiments that investigate the effects of particle size, composition and concentration on finger generation and dynamics. The experimental set-up consists of a Plexiglas tank equipped with a removable plastic sheet that separates two different layers. The lower layer is a solution of water and sugar, initially denser than the upper layer, which consists of water and particles. Particles in the experiments include glass beads as well as andesitic, rhyolitic and basaltic volcanic ash. During the experiments, we removed the horizontal plastic sheet separating the two fluids. Particles were illuminated with a laser and filmed with a HD camera; particle image velocimetry (PIV) is used to analyse finger dynamics. Results show that both the number and the downward advance speed of fingers increase with particle concentration in the upper layer, while finger speed increases with particle size but is independent of particle composition. An increase in particle concentration and turbulence is estimated to take place inside the fingers, which could promote aggregation in subaerial fallout events. Finally, finger number, finger speed and particle concentration were observed to decrease with time after the formation of fingers. A similar pattern could occur in volcanic clouds when the mass supply from the eruptive vent is reduced. Observed evolution of the experiments through time also indicates that there must be a threshold of fine ash concentration and mass eruption rate below which fingers do not form; this is also confirmed by field observations.

  1. Modeling the finger joint moments in a hand at the maximal isometric grip: the effects of friction.

    PubMed

    Wu, John Z; Dong, Ren G; McDowell, Thomas W; Welcome, Daniel E

    2009-12-01

    The interaction between the handle and operator's hand affects the comfort and safety of tool and machine operations. In most of the previous studies, the investigators considered only the normal contact forces. The effect of friction on the joint moments in fingers has not been analyzed. Furthermore, the observed contact forces have not been linked to the internal musculoskeletal loading in the previous experimental studies. In the current study, we proposed a universal model of a hand to evaluate the joint moments in the fingers during grasping tasks. The hand model was developed on the platform of the commercial software package AnyBody. Only four fingers (index, long, ring, and little finger) were included in the model. The anatomical structure of each finger is comprised of four phalanges (distal, middle, proximal, and metacarpal phalange). The simulations were performed using an inverse dynamics technique. The joint angles and the normal contact forces on each finger section reported by previous researchers were used as inputs, while the joint moments of each finger were predicted. The predicted trends of the dependence of the distal interphalangeal (DIP) and proximal interphalangeal (PIP) joint moments on the cylinder diameter agree with those of the contact forces on the fingers observed in the previous experimental study. Our results show that the DIP and PIP joint moments reach their maximums at a cylinder diameter of about 31mm, which is consistent with the trend of the finger contact forces measured in the experiments. The proposed approach will be useful for simulating musculoskeletal loading in the hand for occupational activities, thereby optimizing tool-handle design.

  2. Dangers of neglect: partially embedded ring upon a finger.

    PubMed

    Kumar, Anand; Edwards, Huw; Lidder, Surjit; Mestha, Prabhakar

    2013-05-09

    Digital swelling is a common presentation in clinical practice. Patients presenting with swollen fingers to the emergency department will often have rings on their finger, which can be removed using a variety of simple non-operative techniques or by cutting the ring off and thus avoiding any long-term consequences. Very rarely, when there is a delay in presentation of these patients, serious consequences may proceed, including finger ischaemia, infection, tendon attrition or ultimately the need for surgical amputation. We present an unusual case of patient with psychiatric illness who presented late with a ring that had embedded upon the volar aspect of the index finger. The difficulties faced by the emergency care practitioners in such circumstances, the consequences of rings acting as a tourniquet and strategies for removal of rings on swollen fingers are highlighted.

  3. Intramanual and intermanual transfer of the curvature aftereffect

    PubMed Central

    Duijndam, Maarten J. A.; Ketels, Myrna F. M.; Wilbers, Martine T. J. M.; Zwijsen, Sandra A.; Kappers, Astrid M. L.

    2008-01-01

    The existence and transfer of a haptic curvature aftereffect was investigated to obtain a greater insight into neural representation of shape. The haptic curvature aftereffect is the phenomenon whereby a flat surface is judged concave if the preceding touched stimulus was convex and vice versa. Single fingers were used to touch the subsequently presented stimuli. A substantial aftereffect was found when the adaptation surface and the test surface were touched by the same finger. Furthermore, a partial, but significant transfer of the aftereffect was demonstrated between fingers of the same hand and between fingers of both the hands. These results provide evidence that curvature information is not only represented at a level that is directly connected to the mechanoreceptors of individual fingers but is also represented at a stage in the somatosensory cortex shared by the fingers of both the hands. PMID:18438649

  4. [Symbrachydactyly].

    PubMed

    Samson, P; Mevio, G

    2008-12-01

    Symbrachydactyly is literally defined as a combination of short fingers with syndactyly. Blauth and Gekeler described four types of symbrachydactyly, ranging from simple shortness of middle phalanges to complete absence of digital rays. In type I (short finger) function is quite normal and syndactyly release is usually the only procedure needed. In type II (cleft hand), presence of a thumb and at least one ulnar finger allows pinch function. Surgical treatment, when needed, consists in separation of webbed fingers, resection of nonfunctional digital stumps, or finger translocation. In type III (monodactyly) all long fingers are absent. Pinch function can be created between the thumb and a toe transfer in ulnar location. Bone lengthening is an alternative procedure to create a pincer. Surgery is not always indicated in type IV (peromely) as function can only be restored if active motion is already present at wrist or carpometacarpal levels.

  5. Design and control of five fingered under-actuated robotic hand

    NASA Astrophysics Data System (ADS)

    Sahoo, Biswojit; Parida, Pramod Kumar

    2018-04-01

    Now a day's research regarding humanoid robots and its application in different fields (industry, household, rehabilitation and exploratory) is going on entire the globe. Among which a challenging topic is to design a dexterous robotic hand which not only can perform as a hand of a robot but also can be used in re habilitation. The basic key concern is a dexterous robot hand which can be able to mimic the function of biological hand to perform different operations. This thesis work is regarding design and control of a under-actuated robotic hand consisting of four under actuated fingers (index finger, middle finger, little finger and ring finger ) , a thumb and a dexterous palm which can copy the motions and grasp type of human hand which having 21degrees of freedom instead of 25Degree Of Freedom.

  6. Affiliative stimuli as primers to prosocial predispositions.

    PubMed

    Souza, Gabriela Guerra Leal; Pereira, Mirtes Garcia; Vila, Jaime; Oliveira, Leticia; Volchan, Eliane

    2012-03-01

    Affiliative stimuli are pleasant and highly biologically relevant. Affiliative cues are thought to elicit a prosocial predisposition. Here affiliative and neutral pictures were exposed prior to a reaction time task which consisted in responding to a visual target. Half the participants responded with finger-flexion, a movement frequently involved in prosocial activities. The other half responded with finger extension, a less prosocially compatible movement. Results showed that under the exposure to affiliative pictures, as compared to neutral ones, participants who used finger flexion were faster, while those using finger extension were slower. Performance benefits to the task, when flexing the finger, together with performance costs, when extending it, indicate the relevance of movement compatibility to the context. These findings put forward a possible link between affiliative primers and motor preparation to facilitate a repertoire of movements related to prosocial predispositions including finger flexion.

  7. Graphical representation of robot grasping quality measures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Varma, V.; Tasch, U.

    1993-11-01

    When an object is held by a multi-fingered hand, the values of the contact forces can be multivalued. An objective function, when used in conjunction with the frictional and geometric constraints of the grasp, can however, give a unique set of finger force values. The selection of the objective function in determining the finger forces is dependent on the type of grasp required, the material properties of the object, and the limitations of the robot fingers. In this paper several optimization functions are studied and their merits highlighted. A graphical representation of the finger force values and the objective functionmore » is introduced that enable one in selecting and comparing various grasping configurations. The impending motion of the object at different torque and finger force values are determined by observing the normalized coefficient of friction plots.« less

  8. Transfer of piano practice in fast performance of skilled finger movements.

    PubMed

    Furuya, Shinichi; Nakamura, Ayumi; Nagata, Noriko

    2013-11-01

    Transfer of learning facilitates the efficient mastery of various skills without practicing all possible sensory-motor repertoires. The present study assessed whether motor practice at a submaximal speed, which is typical in sports and music performance, results in an increase in a maximum speed of finger movements of trained and untrained skills. Piano practice of sequential finger movements at a submaximal speed over days progressively increased the maximum speed of trained movements. This increased maximum speed of finger movements was maintained two months after the practice. The learning transferred within the hand to some extent, but not across the hands. The present study confirmed facilitation of fast finger movements following a piano practice at a submaximal speed. In addition, the findings indicated the intra-manual transfer effects of piano practice on the maximum speed of skilled finger movements.

  9. Finger-Based Numerical Skills Link Fine Motor Skills to Numerical Development in Preschoolers.

    PubMed

    Suggate, Sebastian; Stoeger, Heidrun; Fischer, Ursula

    2017-12-01

    Previous studies investigating the association between fine-motor skills (FMS) and mathematical skills have lacked specificity. In this study, we test whether an FMS link to numerical skills is due to the involvement of finger representations in early mathematics. We gave 81 pre-schoolers (mean age of 4 years, 9 months) a set of FMS measures and numerical tasks with and without a specific finger focus. Additionally, we used receptive vocabulary and chronological age as control measures. FMS linked more closely to finger-based than to nonfinger-based numerical skills even after accounting for the control variables. Moreover, the relationship between FMS and numerical skill was entirely mediated by finger-based numerical skills. We concluded that FMS are closely related to early numerical skill development through finger-based numerical counting that aids the acquisition of mathematical mental representations.

  10. Dexterity with numbers: rTMS over left angular gyrus disrupts finger gnosis and number processing.

    PubMed

    Rusconi, Elena; Walsh, Vincent; Butterworth, Brian

    2005-01-01

    Since the original description of Gerstmann's syndrome with its four cardinal symptoms, among which are finger agnosia and acalculia, the neuro-cognitive relationship between fingers and calculation has been debated. We asked our participants to perform four different tasks, two of which involved fingers and the other two involving numbers, during repetitive transcranial magnetic stimulation (rTMS) over the posterior parietal lobe of either hemisphere. In the finger tasks, they were required to transform a tactile stimulus randomly delivered on one of their fingers into a speeded key-press response either with the same or with the homologous finger on the opposite hand. In the numerical tasks, they were asked to perform a magnitude or a parity matching on pairs of single digits, in the context of arithmetically related or unrelated numerical primes. In accordance with the original anatomical hypothesis put forward by Gerstmann [Gerstmann, J. (1924). Fingeragnosie: eine umschriebene Stoerung der Orienterung am eigenen Koerper. Wiener clinische Wochenschrift, 37, 1010-12], we found that rTMS over the left angular gyrus disrupted tasks requiring access to the finger schema and number magnitude processing in the same group of participants. In addition to the numerous studies which have employed special populations such as neurological patients and children, our data confirm the presence of a relationship between numbers and body knowledge in skilled adults who no longer use their fingers for solving simple arithmetical tasks.

  11. Downward finger displacement distinguishes Parkinson disease dementia from Alzheimer disease.

    PubMed

    Lieberman, Abraham; Deep, Aman; Shi, Jiong; Dhall, Rohit; Shafer, Saulena; Moguel-Cobos, Guillermo; Dhillon, Ravneet; Frames, Christopher W; McCauley, Margaret

    2018-02-01

    Purpose/Aim of the study: To study finger displacement in patients with Parkinson disease dementia (PDD) and in patients with Alzheimer disease (AD). We examined 56 patients with PDD and 35 with AD. Patients were examined during their regular outpatient clinic visit. Finger displacement was measured by observers not actively involved in the study using a creative grid ruler for all PDD and AD patients. Finger displacement was examined by asking patients to point their index fingers toward the grid ruler with the nails facing upward. Patients were asked to maintain the pointing position for 15 s. After 15 s, patients were asked to close their eyes for another 15 s while maintaining the same position. A positive result was downward index finger displacement of ≥5 cm within the 15-second time window with eyes closed. Of the 56 PDD patients, 53 had bilateral finger displacement of >5 cm. In comparison, of the 35 AD patients, only 1 patient had minimal displacement. Results of the non-invasive finger displacement test may provide insight, on an outpatient basis, of the integrity of subcortical-cortical circuits. Downward finger displacement, especially bilateral downward displacement, may signal the extensive disruption of subcortical-cortical circuits that occurs in PDD patients. AChE: acetylcholinesterase; AD: Alzheimer disease; DLB: dementia with Lewy bodies; ET: essential tremor; MDS-UPDRS: Movement Disorder Society-sponsored Unified Parkinson's Disease Rating Scale; MMSE: Mini-Mental State Examination; PD: Parkinson disease; PDD: Parkinson disease dementia.

  12. Difference of motor overflow depending on the impaired or unimpaired hand in stroke patients.

    PubMed

    Kim, Yushin; Kim, Woo-Sub; Shim, Jae Kun; Suh, Dong Won; Kim, TaeYeong; Yoon, BumChul

    2015-02-01

    The aim of this study was to investigate the patterns of contralateral motor overflow (i.e. mirror movement) between the homologous body parts on the right and left side, in stroke patients during single-finger and multi-finger maximum force production tasks. Forty subjects, including stroke (n=20) and normal subjects (n=20), participated in this study. The stroke subjects maximally pressed force sensors with their fingers in a flexed position using a single (index, middle, ring, or little) or all fingers (all 4 fingers) using the impaired (IH) or unimpaired (UIH) hand, while the non-patient subjects used their right hands for the same tasks. The maximal voluntary forces in the ipsilateral and unintended pressing forces of each contralateral finger were recorded during the tasks. The magnitude of motor overflow to the contralateral side was calculated using the index of contralateral independence (CI). During the single finger tasks, the finger CI was significantly decreased in the UIH (91%) compared with that in the IH (99%) or normal hands (99%). Likewise, the multiple finger tasks showed that the CI was significantly lower in the UIH (84%) compared with that in the IH (96%) or normal hands (99%). However, the maximal forces were significantly lower in the IH relative to those in the UIH and normal hands. These data demonstrate that stroke patients have greater motor overflow from the UIH to the IH. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Hand kinematics of piano playing

    PubMed Central

    Flanders, Martha; Soechting, John F.

    2011-01-01

    Dexterous use of the hand represents a sophisticated sensorimotor function. In behaviors such as playing the piano, it can involve strong temporal and spatial constraints. The purpose of this study was to determine fundamental patterns of covariation of motion across joints and digits of the human hand. Joint motion was recorded while 5 expert pianists played 30 excerpts from musical pieces, which featured ∼50 different tone sequences and fingering. Principal component analysis and cluster analysis using an expectation-maximization algorithm revealed that joint velocities could be categorized into several patterns, which help to simplify the description of the movements of the multiple degrees of freedom of the hand. For the thumb keystroke, two distinct patterns of joint movement covariation emerged and they depended on the spatiotemporal patterns of the task. For example, the thumb-under maneuver was clearly separated into two clusters based on the direction of hand translation along the keyboard. While the pattern of the thumb joint velocities differed between these clusters, the motions at the metacarpo-phalangeal and proximal-phalangeal joints of the four fingers were more consistent. For a keystroke executed with one of the fingers, there were three distinct patterns of joint rotations, across which motion at the striking finger was fairly consistent, but motion of the other fingers was more variable. Furthermore, the amount of movement spillover of the striking finger to the adjacent fingers was small irrespective of the finger used for the keystroke. These findings describe an unparalleled amount of independent motion of the fingers. PMID:21880938

  14. Contactless optical scanning of fingerprints with 180 degrees view.

    PubMed

    Palma, J; Liessner, C; Mil'shtein, S

    2006-01-01

    Fingerprint recognition technology is an integral part of criminal investigations. It is the basis for the design of numerous security systems in both the private and public sectors. In a recent study emulating the fingerprinting procedure with widely used optical scanners, it was found that, on average, the distance between ridges decreases about 20% when a finger is positioned on a scanner. Using calibrated silicon pressure sensors, the authors scanned the distribution of pressure across a finger, pixel by pixel, and also generated maps of the average pressure distribution during fingerprinting. Controlled loading of a finger demonstrated that it is impossible to reproduce the same distribution of pressure across a given finger during repeated fingerprinting procedures. Based on this study, a novel method of scanning the fingerprint with more than a 180 degrees view was developed. Using a camera rotated around the finger, small slices of the entire image of the finger were acquired. Equal sized slices of the image were processed with a special program assembling a more than 180 degrees view of the finger. Comparison of two images of the same fingerprint, namely the registered and actual images, could be performed by a new algorithm based on the symmetry of the correlation function. The novel method is the first contactless optical scanning technique to view 180 degrees of a fingerprint without moving the finger. In a machine which is under design, it is expected that the full view of one finger would be acquired in about a second.

  15. Bioinspired Robotic Fingers Based on Pneumatic Actuator and 3D Printing of Smart Material.

    PubMed

    Yang, Yang; Chen, Yonghua; Li, Yingtian; Chen, Michael Z Q; Wei, Ying

    2017-06-01

    In this article, we have proposed a novel robotic finger design principle aimed to address two challenges in soft pneumatic grippers-the controllability of the stiffness and the controllability of the bending position. The proposed finger design is composed of a 3D printed multimaterial substrate and a soft pneumatic actuator. The substrate has four polylactic acid (PLA) segments interlocked with three shape memory polymer (SMP) joints, inspired by bones and joints in human fingers. By controlling the thermal energy of an SMP joint, the stiffness of the joints is modulated due to the dramatic change in SMP elastic modulus around its glass transition temperature (T g ). When SMP joints are heated above T g , they exhibit very small stiffness, allowing the finger to easily bend around the SMP joints if the attached soft actuator is actuated. When there is no force from the soft actuator, shape recovery stress in SMP contributes to the finger's shape restoration. Since each joint's rotation can be individually controlled, the position control of the finger is made possible. Experimental analysis has been conducted to show the finger's variable stiffness and the result is compared with the analytical values. It is found that the stiffness ratio can be 24.9 times for a joint at room temperature (20°C) and at an elevated temperature of 60°C when air pressure p of the soft actuator is turned off. Finally, a gripper composed of two fingers is fabricated for demonstration.

  16. Instrumented Glove Measures Positions Of Fingers

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr.

    1993-01-01

    Glove instrumented with flat membrane potentiometers to obtain crude measurements of relative positions of fingers. Resistance of each potentiometer varies with position of associated finger; translator circuit connected to each potentiometer converts analog reading to 1 of 10 digital levels. Digitized outputs from all fingers fed to indicating, recording, and/or data-processing equipment. Gloves and circuits intended for use in biomedical research, training in critical manual tasks, and other specialized applications.

  17. Classification of finger movements by using the ultra-wide band radar.

    PubMed

    Eldosoky, Mohamed A A

    2010-12-01

    The coding system of finger movements depends on the differences in the characteristics of the muscles that are responsible for these movements. The ability of ultra-wide band (UWB) radar for use as a tool for identifying the movements of each finger is presented. This will facilitate the ability of the UWB radar in designing a coding system for the movement of fingers of each hand.

  18. Prosthetic Hand With Two Gripping Fingers

    NASA Technical Reports Server (NTRS)

    Norton, William E.; Belcher, Jewell B.; Vest, Thomas W.; Carden, James R.

    1993-01-01

    Prosthetic hand developed for amputee who retains significant portion of forearm. Outer end of device is end effector including two fingers, one moved by rotating remaining part of forearm about its longitudinal axis. Main body of end effector is end member supporting fingers, roller bearing assembly, and rack-and-pinion mechanism. Advantage of rack-and-pinion mechanism enables user to open or close gap between fingers with precision and force.

  19. The speech focus position effect on jaw-finger coordination in a pointing task.

    PubMed

    Rochet-Capellan, Amélie; Laboissière, Rafael; Galván, Arturo; Schwartz, Jean-Luc

    2008-12-01

    This article investigates jaw-finger coordination in a task involving pointing to a target while naming it with a CVCV (e.g., /papa/) versus CVCV (e.g., /papa/) word. According to the authors' working hypothesis, the pointing apex (gesture extremum) would be synchronized with the apex of the jaw-opening gesture corresponding to the stressed syllable. Jaw and finger motions were recorded using Optotrak (Northern Digital, Waterloo, Ontario, Canada). The effects of stress position on jaw-finger coordination were tested across different target positions (near vs. far) and different consonants in the target word (/t/ vs. /p/). Twenty native Portuguese Brazilian speakers participated in the experiment (all conditions). Jaw response starts earlier, and finger-target alignment period is longer for CVCV words than for CVCV ones. The apex of the jaw-opening gesture for the stressed syllable appears synchronized with the onset of the finger-target alignment period (corresponding to the pointing apex) for CVCV words and with the offset of that period for CVCV words. For both stress conditions, the stressed syllable occurs within the finger-target alignment period because of tight finger-jaw coordination. This result is interpreted as evidence for an anchoring of the speech deictic site (part of speech that shows) in the pointing gesture.

  20. Growth-direction dependence of steady-state Saffman-Taylor flow in an anisotropic Hele-Shaw cell

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCloud, K.V.; Maher, J.V.

    1996-08-01

    Selection of steady-state fingers has been measured in a Hele-Shaw cell perturbed by having a square lattice etched onto one of the plates. Flows at different orientations {theta} between the direction of flow and the lattice axes have been studied, in a wide range of observable tip velocities where the perturbation was made microscopic in the sense that the capillary length of the flow was much greater than the etched lattice cell size. The full range of dynamically interesting angles for the square lattice was examined, and above a threshold, the microscopic perturbation always results in wider fingers than aremore » selected in the unperturbed case. There is some dependence of the width of the fingers on the orientation of the flow, with fingers at {theta}=0{degree} being the widest with respect to the unperturbed fingers, and fingers at 45{degree} being the least wide, although still wider than the unperturbed fingers. All observed solutions are symmetric, centered in the channel, and have the relation between tip-curvature and finger width expected of members of the Saffman-Taylor family of solutions. Selected solutions narrow again at tip velocities where the perturbation can no longer be considered microscopic. {copyright} {ital 1996 The American Physical Society.}« less

  1. A cross sectional study on hand-arm vibration syndrome among a group of tree fellers in a tropical environment.

    PubMed

    Su, Anselm Ting; Maeda, Setsuo; Fukumoto, Jin; Miyai, Nobuyuki; Isahak, Marzuki; Yoshioka, Atsushi; Nakajima, Ryuichi; Bulgiba, Awang; Miyashita, Kazuhisa

    2014-01-01

    This study aimed to explore the clinical characteristics of hand arm vibration syndrome (HAVS) in a group of tree fellers in a tropical environment. We examined all tree fellers and selected control subjects in a logging camp of central Sarawak for vibration exposure and presence of HAVS symptoms utilizing vibrotactile perception threshold test (VPT) and cold water provocation test (CWP). None of the subjects reported white finger. The tree fellers reported significantly higher prevalence of finger coldness as compared to the control subjects (OR=10.32, 95%CI=1.21-87.94). A lower finger skin temperature, longer fingernail capillary return time and higher VPT were observed among the tree fellers as compared to the control subjects in all fingers (effect size >0.5). The VPT following CWP of the tree fellers was significantly higher (repeated measures ANOVA p=0.002, partial η(2)=0.196) than the control subject. The A (8) level was associated with finger tingling, numbness and dullness (effect size=0.983) and finger coldness (effect size=0.524) among the tree fellers. Finger coldness and finger tingling, numbness and dullness are important symptoms for HAVS in tropical environment that may indicate vascular and neurological damage due to hand-transmitted vibration exposure.

  2. Keep your fingers off my DNA: protein-protein interactions mediated by C2H2 zinc finger domains.

    PubMed

    Brayer, Kathryn J; Segal, David J

    2008-01-01

    Cys2-His2 (C2H2) zinc finger domains (ZFs) were originally identified as DNA-binding domains, and uncharacterized domains are typically assumed to function in DNA binding. However, a growing body of evidence suggests an important and widespread role for these domains in protein binding. There are even examples of zinc fingers that support both DNA and protein interactions, which can be found in well-known DNA-binding proteins such as Sp1, Zif268, and Ying Yang 1 (YY1). C2H2 protein-protein interactions (PPIs) are proving to be more abundant than previously appreciated, more plastic than their DNA-binding counterparts, and more variable and complex in their interactions surfaces. Here we review the current knowledge of over 100 C2H2 zinc finger-mediated PPIs, focusing on what is known about the binding surface, contributions of individual fingers to the interaction, and function. An accurate understanding of zinc finger biology will likely require greater insights into the potential protein interaction capabilities of C2H2 ZFs.

  3. Finger crease pattern recognition using Legendre moments and principal component analysis

    NASA Astrophysics Data System (ADS)

    Luo, Rongfang; Lin, Tusheng

    2007-03-01

    The finger joint lines defined as finger creases and its distribution can identify a person. In this paper, we propose a new finger crease pattern recognition method based on Legendre moments and principal component analysis (PCA). After obtaining the region of interest (ROI) for each finger image in the pre-processing stage, Legendre moments under Radon transform are applied to construct a moment feature matrix from the ROI, which greatly decreases the dimensionality of ROI and can represent principal components of the finger creases quite well. Then, an approach to finger crease pattern recognition is designed based on Karhunen-Loeve (K-L) transform. The method applies PCA to a moment feature matrix rather than the original image matrix to achieve the feature vector. The proposed method has been tested on a database of 824 images from 103 individuals using the nearest neighbor classifier. The accuracy up to 98.584% has been obtained when using 4 samples per class for training. The experimental results demonstrate that our proposed approach is feasible and effective in biometrics.

  4. You can count on the motor cortex: Finger counting habits modulate motor cortex activation evoked by numbers

    PubMed Central

    Tschentscher, Nadja; Hauk, Olaf; Fischer, Martin H.; Pulvermüller, Friedemann

    2012-01-01

    The embodied cognition framework suggests that neural systems for perception and action are engaged during higher cognitive processes. In an event-related fMRI study, we tested this claim for the abstract domain of numerical symbol processing: is the human cortical motor system part of the representation of numbers, and is organization of numerical knowledge influenced by individual finger counting habits? Developmental studies suggest a link between numerals and finger counting habits due to the acquisition of numerical skills through finger counting in childhood. In the present study, digits 1 to 9 and the corresponding number words were presented visually to adults with different finger counting habits, i.e. left- and right-starters who reported that they usually start counting small numbers with their left and right hand, respectively. Despite the absence of overt hand movements, the hemisphere contralateral to the hand used for counting small numbers was activated when small numbers were presented. The correspondence between finger counting habits and hemispheric motor activation is consistent with an intrinsic functional link between finger counting and number processing. PMID:22133748

  5. Custom-Made Finger Guard to Prevent Wire-Stick Injury to the Operator's Finger while Performing Intermaxillary Fixation.

    PubMed

    Kumaresan, Ramesh; Ponnusami, Karthikeyan; Karthikeyan, Priyadarshini

    2014-12-01

    The treatment of maxillofacial fractures involves different methods from bandages and splinting to methods of open reduction and internal fixation and usually requires control of the dental occlusion with the help of intermaxillary fixation (IMF). Different wiring techniques have been used to aid in IMF including placement of custom-made arch bars, eyelet etc. However, these wiring techniques are with a constant danger of trauma to the surgeon's fingers by their sharp ends. Though there exist a variety of commercially available barrier products and customized techniques to prevent wire-stick injury, cost factor, touch sensitivity, and comfort aspect restrain their acquirement and exploit. This technical note describes the construction of a simple and economical finger guard made of soft thermoplastic material that provides an added protection to fingers from wire-stick type injuries, and its flexible nature permits a comfortable finger flexion movement and acceptable touch sensitivity. This is a simple, economical, reusable puncture, and cut-resistance figure guard by which we can avoid wire-stick type injury to the operator's fingers during wiring technique.

  6. Bioaccessible mineral content of malted finger millet (Eleusine coracana), wheat (Triticum aestivum), and barley (Hordeum vulgare).

    PubMed

    Platel, Kalpana; Eipeson, Sushma W; Srinivasan, Krishnapura

    2010-07-14

    Malted grains are extensively used in weaning and geriatric foods. Malting generally improves the nutrient content and digestibility of foods. The present investigation examined the influence of malting of finger millet, wheat, and barley on the bioaccessibility of iron, zinc, calcium, copper, and manganese. Malting increased the bioaccessibility of iron by >3-fold from the two varieties of finger millet and by >2-fold from wheat, whereas such a beneficial influence was not seen in barley. The bioaccessibility of zinc from wheat and barley increased to an extent of 234 and 100%, respectively, as a result of malting. However, malting reduced the bioaccessibility of zinc from finger millet. Malting marginally increased the bioaccessibility of calcium from white finger millet and wheat. Whereas malting did not exert any influence on bioaccessibility of copper from finger millet and wheat, it significantly decreased (75%) the same from barley. Malting did increase the bioaccessibility of manganese from brown finger millet (17%) and wheat (42%). Thus, malting could be an appropriate food-based strategy to derive iron and other minerals maximally from food grains.

  7. Differential involvement of forearm muscles in ALS does not relate to sonographic structural nerve alterations.

    PubMed

    Schreiber, Stefanie; Schreiber, Frank; Debska-Vielhaber, Grazyna; Garz, Cornelia; Hensiek, Nathalie; Machts, Judith; Abdulla, Susanne; Dengler, Reinhard; Petri, Susanne; Nestor, Peter J; Vielhaber, Stefan

    2018-07-01

    We aimed to assess whether differential peripheral nerve involvement parallels dissociated forearm muscle weakness in amyotrophic lateral sclerosis (ALS). The analysis comprised 41 ALS patients and 18 age-, sex-, height- and weight-matched healthy controls. Strength of finger-extension and -flexion was measured using the Medical Research Council (MRC) scale. Radial, median and ulnar nerve sonographic cross-sectional area (CSA) and echogenicity, expressed by the hypoechoic fraction (HF), were determined. In ALS, finger extensors were significantly weaker than finger flexors. Sonographic evaluation revealed peripheral nerve atrophy, affecting various nerve segments in ALS. HF was unaltered. This systematic study confirmed a long-observed physical examination finding in ALS - weakness in finger-extension out of proportion to finger-flexion. This phenomenon was not related to any particular sonographic pattern of upper limb peripheral nerve alteration. In ALS, dissociated forearm muscle weakness could aid in the disease's diagnosis. Nerve ultrasound did not provide additional information on the differential involvement of finger-extension and finger-flexion strength. Copyright © 2018 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  8. Enhanced left-finger deftness following dominant upper- and lower-limb amputation.

    PubMed

    Swanberg, Kelley M; Clark, Abigail M; Kline, Julia E; Yurkiewicz, Ilana R; Chan, Brenda L; Pasquina, Paul F; Heilman, Kenneth M; Tsao, Jack W

    2011-09-01

    After amputation, the sensorimotor cortex reorganizes, and these alterations might influence motor functions of the remaining extremities. The authors examined how amputation of the dominant or nondominant upper or lower extremity alters deftness in the intact limbs. The participants were 32 unilateral upper- or lower-extremity amputees and 6 controls. Upper-extremity deftness was tested by coin rotation (finger deftness) and pegboard (arm, hand, and finger deftness) tasks. Following right-upper- or right-lower-extremity amputation, the left hand's finger movements were defter than the left-hand fingers of controls. In contrast, with left-upper- or left-lower-extremity amputation, the right hand's finger performance was the same as that of the controls. Although this improvement might be related to increased use (practice), the finding that right-lower-extremity amputation also improved the left hand's finger deftness suggests an alternative mechanism. Perhaps in right-handed persons the left motor cortex inhibits the right side of the body more than the right motor cortex inhibits the left side, and the physiological changes induced by right-sided amputation reduced this inhibition.

  9. Contribution of finger tracing to the recognition of Chinese characters.

    PubMed

    Yim-Ng, Y Y; Varley, R; Andrade, J

    2000-01-01

    Finger tracing is a simulation of the act of writing without the use of pen and paper. It is claimed to help in the processing of Chinese characters, possibly by providing additional motor coding. In this study, blindfolded subjects were equally good at identifying Chinese characters and novel visual stimuli through passive movements made with the index finger of the preferred hand and those made with the last finger of that hand. This suggests that finger tracing provides a relatively high level of coding specific to individual characters, but non-specific to motor effectors. Beginning each stroke from the same location, i.e. removing spatial information, impaired recognition of the familiar characters and the novel nonsense figures. Passively tracing the strokes in a random sequence also impaired recognition of the characters. These results therefore suggest that the beneficial effect of finger tracing on writing or recall of Chinese characters is mediated by sequence and spatial information embedded in the motor movements, and that proprioceptive channel may play a part in mediating visuo-spatial information. Finger tracing may be a useful strategy for remediation of Chinese language impairments.

  10. Luciferase-Zinc-Finger System for the Rapid Detection of Pathogenic Bacteria.

    PubMed

    Shi, Chu; Xu, Qing; Ge, Yue; Jiang, Ling; Huang, He

    2017-08-09

    Rapid and reliable detection of pathogenic bacteria is crucial for food safety control. Here, we present a novel luciferase-zinc finger system for the detection of pathogens that offers rapid and specific profiling. The system, which uses a zinc-finger protein domain to probe zinc finger recognition sites, was designed to bind the amplified conserved regions of 16S rDNA, and the obtained products were detected using a modified luciferase. The luciferase-zinc finger system not only maintained luciferase activity but also allowed the specific detection of different bacterial species, with a sensitivity as low as 10 copies and a linear range from 10 to 10 4 copies per microliter of the specific PCR product. Moreover, the system is robust and rapid, enabling the simultaneous detection of 6 species of bacteria in artificially contaminated samples with excellent accuracy. Thus, we envision that our luciferase-zinc finger system will have far-reaching applications.

  11. Salt-Finger Convection in a Stratified Fluid Layer Induced by Thermal and Solutal Capillary Motion

    NASA Technical Reports Server (NTRS)

    Chen, Chuan F.; Chan, Cho Lik

    1996-01-01

    Salt-finger convection in a double-diffusive system is a motion driven by the release of gravitational potential due to different diffusion rates. Normally, when the gravitational field is reduced, salt-finger convection together with other convective motions driven by buoyancy forces will be rapidly suppressed. However, because the destabilizing effect of the concentration gradient is amplified by the Lewis number, with values varying from 10(exp 2) for aqueous salt solutions to 10 (exp 4) for liquid metals, salt-finger convection may be generated at much reduced gravity levels. In the microgravity environment, the surface tension gradient assumes a dominant role in causing fluid motion. In this paper, we report on some experimental results showing the generation of salt-finger convection due to capillary motio on the surface of a stratified fluid layer. A numerical simulation is presented to show the cause of salt-finger convection.

  12. Evaluation of Novel Design Strategies for Developing Zinc Finger Nucleases Tools for Treating Human Diseases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bach, Christian; Sherman, William; Pallis, Jani

    Zinc finger nucleases (ZFNs) are associated with cell death and apoptosis by binding at countless undesired locations. This cytotoxicity is associated with the binding ability of engineered zinc finger domains to bind dissimilar DNA sequences with high affinity. In general, binding preferences of transcription factors are associated with significant degenerated diversity and complexity which convolutes the design and engineering of precise DNA binding domains. Evolutionary success of natural zinc finger proteins, however, evinces that nature created specific evolutionary traits and strategies, such as modularity and rank-specific recognition to cope with binding complexity that are critical for creating clinical viable toolsmore » to precisely modify the human genome. Our findings indicate preservation of general modularity and significant alteration of the rank-specific binding preferences of the three-finger binding domain of transcription factor SP1 when exchanging amino acids in the 2nd finger.« less

  13. Human motor cortical activity recorded with Micro-ECoG electrodes, during individual finger movements.

    PubMed

    Wang, W; Degenhart, A D; Collinger, J L; Vinjamuri, R; Sudre, G P; Adelson, P D; Holder, D L; Leuthardt, E C; Moran, D W; Boninger, M L; Schwartz, A B; Crammond, D J; Tyler-Kabara, E C; Weber, D J

    2009-01-01

    In this study human motor cortical activity was recorded with a customized micro-ECoG grid during individual finger movements. The quality of the recorded neural signals was characterized in the frequency domain from three different perspectives: (1) coherence between neural signals recorded from different electrodes, (2) modulation of neural signals by finger movement, and (3) accuracy of finger movement decoding. It was found that, for the high frequency band (60-120 Hz), coherence between neighboring micro-ECoG electrodes was 0.3. In addition, the high frequency band showed significant modulation by finger movement both temporally and spatially, and a classification accuracy of 73% (chance level: 20%) was achieved for individual finger movement using neural signals recorded from the micro-ECoG grid. These results suggest that the micro-ECoG grid presented here offers sufficient spatial and temporal resolution for the development of minimally-invasive brain-computer interface applications.

  14. Development of hand rehabilitation system for paralysis patient - universal design using wire-driven mechanism.

    PubMed

    Yamaura, Hiroshi; Matsushita, Kojiro; Kato, Ryu; Yokoi, Hiroshi

    2009-01-01

    We have developed a hand rehabilitation system for patients suffering from paralysis or contracture. It consists of two components: a hand rehabilitation machine, which moves human finger joints with motors, and a data glove, which provides control of the movement of finger joints attached to the rehabilitation machine. The machine is based on the arm structure type of hand rehabilitation machine; a motor indirectly moves a finger joint via a closed four-link mechanism. We employ a wire-driven mechanism and develop a compact design that can control all three joints (i.e., PIP, DIP and MP ) of a finger and that offers a wider range of joint motion than conventional systems. Furthermore, we demonstrate the hand rehabilitation process, finger joints of the left hand attached to the machine are controlled by the finger joints of the right hand wearing the data glove.

  15. Development of a CPM Machine for Injured Fingers.

    PubMed

    Fu, Yili; Zhang, Fuxiang; Ma, Xin; Meng, Qinggang

    2005-01-01

    Human fingers are easy to be injured. A CPM machine is a mechanism based on the rehabilitation theory of continuous passive motion (CPM). To develop a CPM machine for the clinic application in the rehabilitation of injured fingers is a significant task. Therefore, based on the theories of evidence based medicine (EBM) and CPM, we've developed a set of biomimetic mechanism after modeling the motions of fingers and analyzing its kinematics and dynamics analysis. We also design an embedded operating system based on ARM (a kind of 32-bit RISC microprocessor). The equipment can achieve the precise control of moving scope of fingers, finger's force and speed. It can serves as a rational checking method and a way of assessment for functional rehabilitation of human hands. Now, the first prototype has been finished and will start the clinical testing in Harbin Medical University shortly.

  16. Viscous fingering with partially miscible fluids

    NASA Astrophysics Data System (ADS)

    Fu, Xiaojing; Cueto-Felgueroso, Luis; Juanes, Ruben

    2017-10-01

    Viscous fingering—the fluid-mechanical instability that takes place when a low-viscosity fluid displaces a high-viscosity fluid—has traditionally been studied under either fully miscible or fully immiscible fluid systems. Here we study the impact of partial miscibility (a common occurrence in practice) on the fingering dynamics. Through a careful design of the thermodynamic free energy of a binary mixture, we develop a phase-field model of fluid-fluid displacements in a Hele-Shaw cell for the general case in which the two fluids have limited (but nonzero) solubility into one another. We show, by means of high-resolution numerical simulations, that partial miscibility exerts a powerful control on the degree of fingering: fluid dissolution hinders fingering while fluid exsolution enhances fingering. We also show that, as a result of the interplay between compositional exchange and the hydrodynamic pattern-forming process, stronger fingering promotes the system to approach thermodynamic equilibrium more quickly.

  17. Nonlinear unstable viscous fingers in Hele--Shaw flows. I. Experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kopf-Sill, A.R.; Homsy, G.M.

    1988-02-01

    Post-instability viscous fingering in rectilinear flow in a Hele--Shaw cell has been studied experimentally. Of particular interest was the characterization of the range of length scales associated with tip splitting, over a reasonably wide range of parameters. A digital imaging system was used to record the patterns as a function of time, which allowed properties such as the tip velocity, finger width, perimeter, and area to be studied as functions of time and capillary number. The tip velocity was observed to be approximately constant regardless of the occurrence of splitting events, and the average finger width decreased as the degreemore » of supercriticality increased. Quantitative measures of the fact that there is a limit to the complexity of viscous fingers are provided, and that over the range of parameters studied, no evidence for fractal fingering exists. A discussion of the dynamics of tip splitting explains why this is so.« less

  18. Transfer of piano practice in fast performance of skilled finger movements

    PubMed Central

    2013-01-01

    Background Transfer of learning facilitates the efficient mastery of various skills without practicing all possible sensory-motor repertoires. The present study assessed whether motor practice at a submaximal speed, which is typical in sports and music performance, results in an increase in a maximum speed of finger movements of trained and untrained skills. Results Piano practice of sequential finger movements at a submaximal speed over days progressively increased the maximum speed of trained movements. This increased maximum speed of finger movements was maintained two months after the practice. The learning transferred within the hand to some extent, but not across the hands. Conclusions The present study confirmed facilitation of fast finger movements following a piano practice at a submaximal speed. In addition, the findings indicated the intra-manual transfer effects of piano practice on the maximum speed of skilled finger movements. PMID:24175946

  19. Competition between anisotropic viscous fingers

    NASA Astrophysics Data System (ADS)

    Pecelerowicz, M.; Budek, A.; Szymczak, P.

    2014-09-01

    We consider viscous fingers created by injection of low viscosity fluid into the network of capillaries initially filled with a more viscous fluid (motor oil). Due to the anisotropy of the system and its geometry, such a setup promotes the formation of long-and-thin fingers which then grow and compete for the available flow, interacting through the pressure field. The interaction between the fingers is analyzed using the branched growth formalism of Halsey and Leibig (Phys. Rev. A 46, 7723, 1992) using a number of simple, analytically tractable models. It is shown that as soon as the fingers are allowed to capture the flow from one another, the fixed point appears in the phase space, corresponding to the asymptotic state in which the growth of one of the fingers in hindered by the other. The properties of phase space flows in such systems are shown to be remarkably insensitive to the details of the dynamics.

  20. [Thumb reconstruction in emergency, not including replantation].

    PubMed

    Foucher, G

    2005-10-01

    Many articles have discussed secondary thumb reconstruction but only few have been devoted to acute reconstruction. We propose to artificially separate four circumstances: (i) the thumb is preservable without associated trauma of the fingers. The rule is not to burn the bridge of secondary reconstruction; (ii) the thumb is preservable but a neighboring finger is seriously injured and functionally condemned. The finger has to be used as a "bank" to borrow the necessary anatomical structures for reconstruction of the thumb; (iii) the thumb is not preservable and the lesions of a neighboring finger allow to use it for a pollicization. The difficult decision is between the immediate transposition or maintenance for secondary pollicization. Only finger devascularization is a clear indication for acute pollicization; (iv) Finally when the thumb is not preservable and there is no associate finger injury, it is difficult to assess and inform sufficiently the patient to take a decision. Secondary thumb reconstruction is the best choice.

  1. Evaluation of Novel Design Strategies for Developing Zinc Finger Nucleases Tools for Treating Human Diseases

    DOE PAGES

    Bach, Christian; Sherman, William; Pallis, Jani; ...

    2014-01-01

    Zinc finger nucleases (ZFNs) are associated with cell death and apoptosis by binding at countless undesired locations. This cytotoxicity is associated with the binding ability of engineered zinc finger domains to bind dissimilar DNA sequences with high affinity. In general, binding preferences of transcription factors are associated with significant degenerated diversity and complexity which convolutes the design and engineering of precise DNA binding domains. Evolutionary success of natural zinc finger proteins, however, evinces that nature created specific evolutionary traits and strategies, such as modularity and rank-specific recognition to cope with binding complexity that are critical for creating clinical viable toolsmore » to precisely modify the human genome. Our findings indicate preservation of general modularity and significant alteration of the rank-specific binding preferences of the three-finger binding domain of transcription factor SP1 when exchanging amino acids in the 2nd finger.« less

  2. Biophoton emission from fingernails and fingerprints of living human subjects.

    PubMed

    Kim, Tae Jin; Nam, Kyung Woon; Shin, Hak-Soo; Lee, Sung Muk; Yang, Jong Soo; Soh, Kwang-Sup

    2002-01-01

    Biophotons emitted from the center of fingernails and fingerprints from living humans are measured for twenty healthy subjects. We devised a dark box with a photo multiplier tube (H6180-01, Hamamatsu, Japan) whose spectral range is 300 nm to approximately 650 nm and a mount with a light-receiving hole of diameter 8 mm such that biophotons from the small circular area of nail or print of each finger are detected. Significantly more biophotons are emitted from fingernail than fingerprint for each finger of every subject. For thumb the average biophoton emission rate is 23.0 +/- 4.5 counts per second, and 17.2 +/- 2.0 counts per second from the nail, and print, respectively. There is a slight tendency that the little finger emits less than the other fingers. But some fingers emit far stronger than others, and it depends upon each individual subject which finger emits strongest.

  3. Manipulation of viscous fingering in a radially tapered cell geometry

    NASA Astrophysics Data System (ADS)

    Bongrand, Grégoire; Tsai, Peichun Amy

    2018-06-01

    When a more mobile fluid displaces another immiscible one in a porous medium, viscous fingering propagates with a partial sweep, which hinders oil recovery and soil remedy. We experimentally investigate the feasibility of tuning such fingering propagation in a nonuniform narrow passage with a radial injection, which is widely used in various applications. We show that a radially converging cell can suppress the common viscous fingering observed in a uniform passage, and a full sweep of the displaced fluid is then achieved. The injection flow rate Q can be further exploited to manipulate the viscous fingering instability. For a fixed gap gradient α , our experimental results show a full sweep at a small Q but partial displacement with fingering at a sufficient Q . Finally, by varying α , we identify and characterize the variation of the critical threshold between stable and unstable displacements. Our experimental results reveal good agreement with theoretical predictions by a linear stability analysis.

  4. A neural network for recognizing movement patterns during repetitive self-paced movements of the fingers in opposition to the thumb.

    PubMed

    Van Vaerenbergh, J; Vranken, R; Briers, L; Briers, H

    2001-11-01

    A data glove is a typical input device to control a virtual environment. At the same time it measures movements of wrist and fingers. The purposes of this investigation were to assess the ability of BrainMaker, a neural network, to recognize movement patterns during an opposition task that consisted of repetitive self-paced movements of the fingers in opposition to the thumb. The neural network contained 56 inputs, 3 hidden layers of 20 neurons, and one output. The 5th glove '95 (5DT), a commercial glove especially designed for virtual reality games, was used for finger motion capture. The training of the neural network was successful for recognizing the thumb, the index finger and the ring finger movements during the repetitive self-paced movements and neural network performed well during testing.

  5. Finger Length Ratio (2D:4D) in Central India and an Attempt to Verify Fraternal Birth Order Effect: A Population Based Cross-Sectional Study

    PubMed Central

    Maitra, Chaitali; Jha, Dilip Kumar; Biswas, Rakesh

    2016-01-01

    Introduction A normal physiology of a human being is not mere a series of functions occurring with specific intensities and timing. There are lot of factors that may change the normal physiological activity within normal limits. Finger length ratio is one of the markers of intrauterine androgen exposure and it is debated and contradicted by many authors. Digit ratio varies among the ethnicities. Many Indian studies show that there is considerable difference in finger length ratio in different population. Data regarding Central India was not found on extensive search. Aim To find out the finger length ratio and explore the birth order effect on finger length ratio among the first two successive born in the said population. Materials and Methods We conducted a survey on 1500 volunteer persons (800 male and 700 female) over two years of time. We measured the length of the index finger (2D) and ring finger (4D) of both the hands and asked about their birth order history to find out the digit ratio for Central India population and any existing correlation of the same with birth order. T Test and Analysis of Variance (ANOVA) were used for the measure of significance and difference among the groups. The p< 0.05 was considered to be significant. Results Our study reports that, study population mean for right hand 2D:4D ratio was 0.976 (SD±0.031) and for left hand it was found to be 0.969 (SD±0.035). For males, mean finger length ratio for right hand was 0.967 (SD±0.033) and 0.963 (SD±0.037) for left hand. In females the mean Finger length ratio was 0.982 (SD±0.027) for right hand and 0.974 (SD±0.034) for the left hand respectively. Finger length ratio was found to be significantly less (p=0.03) in males for right hand. No significant (p=0.24) difference was observed for left hand. When assessed fraternal birth order effect among the eldest, second born with elder brother and second born with elder sister groups, no significant (p>0.05) variation for finger length ratio of right and left hands observed in both male and female population. Conclusion Our study reports that the finger length ratio (2D:4D) for Central India population did not show significant association between finger length ratio and fraternal birth order among the first two successive born. PMID:28208849

  6. Role of protein structure and the role of individual fingers in zinc finger protein-DNA recognition: a molecular dynamics simulation study and free energy calculations

    NASA Astrophysics Data System (ADS)

    Hamed, Mazen Y.

    2018-05-01

    Molecular dynamics and MM_GBSA energy calculations on various zinc finger proteins containing three and four fingers bound to their target DNA gave insights into the role of each finger in the DNA binding process as part of the protein structure. The wild type Zif 268 (PDB code: 1AAY) gave a ΔG value of - 76.1 (14) kcal/mol. Zinc fingers ZF1, ZF2 and ZF3 were mutated in one experiment and in another experiment one finger was cut and the rest of the protein was studied for binding. The ΔΔG values for the Zinc Finger protein with both ZF1 and ZF2 mutated was + 80 kcal/mol, while mutating only ZF1 the ΔΔG value was + 52 kcal/mol (relative to the wild type). Cutting ZF3 and studying the protein consisting only of ZF1 linked to ZF2 gave a ΔΔG value of + 68 kcal/mol. Upon cutting ZF1, the resulting ZF2 linked to ZF3 protein gave a ΔΔG value of + 41 kcal/mol. The above results shed light on the importance of each finger in the binding process, especially the role of ZF1 as the anchoring finger followed in importance by ZF2 and ZF3. The energy difference between the binding of the wild type protein Zif268 (1AAY) and that for individual finger binding to DNA according to the formula: ΔΔGlinkers, otherstructuralfactors = ΔGzif268 - (ΔGF1+F2+F3) gave a value = - 44.5 kcal/mol. This stabilization can be attributed to the contribution of linkers and other structural factors in the intact protein in the DNA binding process. DNA binding energies of variant proteins of the wild type Zif268 which differ in their ZF1 amino acid sequence gave evidence of a good relationship between binding energy and recognition and specificity, this finding confirms the reported vital role of ZF1 in the ZF protein scanning and anchoring to the target DNA sequence. The role of hydrogen bonds in both specific and nonspecific amino acid-DNA contacts is discussed in relation to mutations. The binding energies of variant Zinc Finger proteins confirmed the role of ZF1 in the recognition, specificity and anchoring of the zinc finger protein to DNA.

  7. Finger Length Ratio (2D:4D) in Central India and an Attempt to Verify Fraternal Birth Order Effect: A Population Based Cross-Sectional Study.

    PubMed

    Maitra, Arjun; Maitra, Chaitali; Jha, Dilip Kumar; Biswas, Rakesh

    2016-12-01

    A normal physiology of a human being is not mere a series of functions occurring with specific intensities and timing. There are lot of factors that may change the normal physiological activity within normal limits. Finger length ratio is one of the markers of intrauterine androgen exposure and it is debated and contradicted by many authors. Digit ratio varies among the ethnicities. Many Indian studies show that there is considerable difference in finger length ratio in different population. Data regarding Central India was not found on extensive search. To find out the finger length ratio and explore the birth order effect on finger length ratio among the first two successive born in the said population. We conducted a survey on 1500 volunteer persons (800 male and 700 female) over two years of time. We measured the length of the index finger (2D) and ring finger (4D) of both the hands and asked about their birth order history to find out the digit ratio for Central India population and any existing correlation of the same with birth order. T Test and Analysis of Variance (ANOVA) were used for the measure of significance and difference among the groups. The p< 0.05 was considered to be significant. Our study reports that, study population mean for right hand 2D:4D ratio was 0.976 (SD±0.031) and for left hand it was found to be 0.969 (SD±0.035). For males, mean finger length ratio for right hand was 0.967 (SD±0.033) and 0.963 (SD±0.037) for left hand. In females the mean Finger length ratio was 0.982 (SD±0.027) for right hand and 0.974 (SD±0.034) for the left hand respectively. Finger length ratio was found to be significantly less (p=0.03) in males for right hand. No significant (p=0.24) difference was observed for left hand. When assessed fraternal birth order effect among the eldest, second born with elder brother and second born with elder sister groups, no significant (p>0.05) variation for finger length ratio of right and left hands observed in both male and female population. Our study reports that the finger length ratio (2D:4D) for Central India population did not show significant association between finger length ratio and fraternal birth order among the first two successive born.

  8. Role of protein structure and the role of individual fingers in zinc finger protein-DNA recognition: a molecular dynamics simulation study and free energy calculations.

    PubMed

    Hamed, Mazen Y

    2018-05-03

    Molecular dynamics and MM_GBSA energy calculations on various zinc finger proteins containing three and four fingers bound to their target DNA gave insights into the role of each finger in the DNA binding process as part of the protein structure. The wild type Zif 268 (PDB code: 1AAY) gave a ΔG value of - 76.1 (14) kcal/mol. Zinc fingers ZF1, ZF2 and ZF3 were mutated in one experiment and in another experiment one finger was cut and the rest of the protein was studied for binding. The ΔΔG values for the Zinc Finger protein with both ZF1 and ZF2 mutated was + 80 kcal/mol, while mutating only ZF1 the ΔΔG value was + 52 kcal/mol (relative to the wild type). Cutting ZF3 and studying the protein consisting only of ZF1 linked to ZF2 gave a ΔΔG value of + 68 kcal/mol. Upon cutting ZF1, the resulting ZF2 linked to ZF3 protein gave a ΔΔG value of + 41 kcal/mol. The above results shed light on the importance of each finger in the binding process, especially the role of ZF1 as the anchoring finger followed in importance by ZF2 and ZF3. The energy difference between the binding of the wild type protein Zif268 (1AAY) and that for individual finger binding to DNA according to the formula: ΔΔG linkers, otherstructuralfactors  = ΔG zif268  - (ΔG F1+F2+F3 ) gave a value = - 44.5 kcal/mol. This stabilization can be attributed to the contribution of linkers and other structural factors in the intact protein in the DNA binding process. DNA binding energies of variant proteins of the wild type Zif268 which differ in their ZF1 amino acid sequence gave evidence of a good relationship between binding energy and recognition and specificity, this finding confirms the reported vital role of ZF1 in the ZF protein scanning and anchoring to the target DNA sequence. The role of hydrogen bonds in both specific and nonspecific amino acid-DNA contacts is discussed in relation to mutations. The binding energies of variant Zinc Finger proteins confirmed the role of ZF1 in the recognition, specificity and anchoring of the zinc finger protein to DNA.

  9. The role of tactile sensation in online and offline hierarchical control of multi-finger force synergy.

    PubMed

    Koh, Kyung; Kwon, Hyun Joon; Yoon, Bum Chul; Cho, Yongseok; Shin, Joon-Ho; Hahn, Jin-Oh; Miller, Ross H; Kim, Yoon Hyuk; Shim, Jae Kun

    2015-09-01

    The hand, one of the most versatile but mechanically redundant parts of the human body, must overcome imperfect motor commands and inherent noise in both the sensory and motor systems in order to produce desired motor actions. For example, it is nearly impossible to produce a perfectly consistent note during a single violin stroke or to produce the exact same note over multiple strokes, which we denote online and offline control, respectively. To overcome these challenges, the central nervous system synergistically integrates multiple sensory modalities and coordinates multiple motor effectors. Among these sensory modalities, tactile sensation plays an important role in manual motor tasks by providing hand-object contact information. The purpose of this study was to investigate the role of tactile feedback in individual finger actions and multi-finger interactions during constant force production tasks. We developed analytical techniques for the linear decomposition of the overall variance in the motor system in both online and offline control. We removed tactile feedback from the fingers and demonstrated that tactile sensors played a critical role in the online control of synergistic interactions between fingers. In contrast, the same sensors did not contribute to offline control. We also demonstrated that when tactile feedback was removed from the fingers, the combined motor output of individual fingers did not change while individual finger behaviors did. This finding supports the idea of hierarchical control where individual fingers at the lower level work together to stabilize the performance of combined motor output at the higher level.

  10. Stability of multifinger action in different state spaces

    PubMed Central

    Reschechtko, Sasha; Zatsiorsky, Vladimir M.

    2014-01-01

    We investigated stability of action by a multifinger system with three methods: analysis of intertrial variance, application of transient perturbations, and analysis of the system's motion in different state spaces. The “inverse piano” device was used to apply transient (lifting-and-lowering) perturbations to individual fingers during single- and two-finger accurate force production tasks. In each trial, the perturbation was applied either to a finger explicitly involved in the task or one that was not. We hypothesized that, in one-finger tasks, task-specific stability would be observed in the redundant space of finger forces but not in the nonredundant space of finger modes (commands to explicitly involved fingers). In two-finger tasks, we expected that perturbations applied to a nontask finger would not contribute to task-specific stability in mode space. In contrast to our expectations, analyses in both force and mode spaces showed lower stability in directions that did not change total force output compared with directions that did cause changes in total force. In addition, the transient perturbations led to a significant increase in the enslaving index. We consider these results within a theoretical scheme of control with referent body configurations organized hierarchically, using multiple few-to-many mappings organized in a synergic way. The observed volatility of enslaving, greater equifinality of total force compared with elemental variables, and large magnitude of motor equivalent motion in both force and mode spaces provide support for the concept of task-specific stability of performance and the existence of multiple neural loops, which ensure this stability. PMID:25253478

  11. Neural correlates of finger gnosis.

    PubMed

    Rusconi, Elena; Tamè, Luigi; Furlan, Michele; Haggard, Patrick; Demarchi, Gianpaolo; Adriani, Michela; Ferrari, Paolo; Braun, Christoph; Schwarzbach, Jens

    2014-07-02

    Neuropsychological studies have described patients with a selective impairment of finger identification in association with posterior parietal lesions. However, evidence of the role of these areas in finger gnosis from studies of the healthy human brain is still scarce. Here we used functional magnetic resonance imaging to identify the brain network engaged in a novel finger gnosis task, the intermanual in-between task (IIBT), in healthy participants. Several brain regions exhibited a stronger blood oxygenation level-dependent (BOLD) response in IIBT than in a control task that did not explicitly rely on finger gnosis but used identical stimuli and motor responses as the IIBT. The IIBT involved stronger signal in the left inferior parietal lobule (IPL), bilateral precuneus (PCN), bilateral premotor cortex, and left inferior frontal gyrus. In all regions, stimulation of nonhomologous fingers of the two hands elicited higher BOLD signal than stimulation of homologous fingers. Only in the left anteromedial IPL (a-mIPL) and left PCN did signal strength decrease parametrically from nonhomology, through partial homology, to total homology with stimulation delivered synchronously to the two hands. With asynchronous stimulation, the signal was stronger in the left a-mIPL than in any other region, possibly indicating retention of task-relevant information. We suggest that the left PCN may contribute a supporting visuospatial representation via its functional connection to the right PCN. The a-mIPL may instead provide the core substrate of an explicit bilateral body structure representation for the fingers that when disrupted can produce the typical symptoms of finger agnosia. Copyright © 2014 the authors 0270-6474/14/339012-12$15.00/0.

  12. Blood glucose concentrations of arm and finger during dynamic glucose conditions.

    PubMed

    Szuts, Ete Z; Lock, J Paul; Malomo, Kenneth J; Anagnostopoulos, Althea

    2002-01-01

    We set out to determine the physiological difference between the capillary blood of the arm and finger with the greatest possible accuracy using the HemoCue B-glucose analyzer on subjects undergoing a meal tolerance test (MTT) or oral glucose tolerance test (OGTT). MTT study was performed on 50 subjects who drank a liquid meal (Ensure, 40 g of carbohydrates) and who were tested on the arm and finger every 30 min for up to 4 h. OGTT study was performed on 12 subjects who drank a 100-g glucose solution (Glucola) and were tested on the arm and finger every 15 min during the first hour and thereafter every 30 min for up to 3 h. Average percent glucose difference between arm and finger reached a maximal value about 1 h following glucose load, with arm glucose being about 5% lower than that of finger. At other times, average differences were less than this. At the greatest rate of glucose change (>2 mg/dL-min), mean percent bias was found to be about 6%. Despite these measurable differences, when arm results were plotted on the Clarke error grid against finger values, >97% of the data were within zone A (rest in zone B). Thus, physiological differences between arm and finger were clinically insignificant. Our studies with HemoCue confirmed the existence of measurable physiological glucose differences between arm and finger following a glucose challenge, but these differences were found to be clinically insignificant even in those subjects in whom they were measurable.

  13. Stability of multifinger action in different state spaces.

    PubMed

    Reschechtko, Sasha; Zatsiorsky, Vladimir M; Latash, Mark L

    2014-12-15

    We investigated stability of action by a multifinger system with three methods: analysis of intertrial variance, application of transient perturbations, and analysis of the system's motion in different state spaces. The "inverse piano" device was used to apply transient (lifting-and-lowering) perturbations to individual fingers during single- and two-finger accurate force production tasks. In each trial, the perturbation was applied either to a finger explicitly involved in the task or one that was not. We hypothesized that, in one-finger tasks, task-specific stability would be observed in the redundant space of finger forces but not in the nonredundant space of finger modes (commands to explicitly involved fingers). In two-finger tasks, we expected that perturbations applied to a nontask finger would not contribute to task-specific stability in mode space. In contrast to our expectations, analyses in both force and mode spaces showed lower stability in directions that did not change total force output compared with directions that did cause changes in total force. In addition, the transient perturbations led to a significant increase in the enslaving index. We consider these results within a theoretical scheme of control with referent body configurations organized hierarchically, using multiple few-to-many mappings organized in a synergic way. The observed volatility of enslaving, greater equifinality of total force compared with elemental variables, and large magnitude of motor equivalent motion in both force and mode spaces provide support for the concept of task-specific stability of performance and the existence of multiple neural loops, which ensure this stability. Copyright © 2014 the American Physiological Society.

  14. Genome and Transcriptome sequence of Finger millet (Eleusine coracana (L.) Gaertn.) provides insights into drought tolerance and nutraceutical properties.

    PubMed

    Hittalmani, Shailaja; Mahesh, H B; Shirke, Meghana Deepak; Biradar, Hanamareddy; Uday, Govindareddy; Aruna, Y R; Lohithaswa, H C; Mohanrao, A

    2017-06-15

    Finger millet (Eleusine coracana (L.) Gaertn.) is an important staple food crop widely grown in Africa and South Asia. Among the millets, finger millet has high amount of calcium, methionine, tryptophan, fiber, and sulphur containing amino acids. In addition, it has C4 photosynthetic carbon assimilation mechanism, which helps to utilize water and nitrogen efficiently under hot and arid conditions without severely affecting yield. Therefore, development and utilization of genomic resources for genetic improvement of this crop is immensely useful. Experimental results from whole genome sequencing and assembling process of ML-365 finger millet cultivar yielded 1196 Mb covering approximately 82% of total estimated genome size. Genome analysis showed the presence of 85,243 genes and one half of the genome is repetitive in nature. The finger millet genome was found to have higher colinearity with foxtail millet and rice as compared to other Poaceae species. Mining of simple sequence repeats (SSRs) yielded abundance of SSRs within the finger millet genome. Functional annotation and mining of transcription factors revealed finger millet genome harbors large number of drought tolerance related genes. Transcriptome analysis of low moisture stress and non-stress samples revealed the identification of several drought-induced candidate genes, which could be used in drought tolerance breeding. This genome sequencing effort will strengthen plant breeders for allele discovery, genetic mapping, and identification of candidate genes for agronomically important traits. Availability of genomic resources of finger millet will enhance the novel breeding possibilities to address potential challenges of finger millet improvement.

  15. Continuous detection and decoding of dexterous finger flexions with implantable myoelectric sensors.

    PubMed

    Baker, Justin J; Scheme, Erik; Englehart, Kevin; Hutchinson, Douglas T; Greger, Bradley

    2010-08-01

    A rhesus monkey was trained to perform individuated and combined finger flexions of the thumb, index, and middle finger. Nine implantable myoelectric sensors (IMES) were then surgically implanted into the finger muscles of the monkey's forearm, without any adverse effects over two years postimplantation. Using an inductive link, EMG was wirelessly recorded from the IMES as the monkey performed a finger flexion task. The EMG from the different IMES implants showed very little cross correlation. An offline parallel linear discriminant analysis (LDA) based algorithm was used to decode finger activity based on features extracted from continuously presented frames of recorded EMG. The offline parallel LDA was run on intraday sessions as well as on sessions where the algorithm was trained on one day and tested on following days. The performance of the algorithm was evaluated continuously by comparing classification output by the algorithm to the current state of the finger switches. The algorithm detected and classified seven different finger movements, including individual and combined finger flexions, and a no-movement state (chance performance = 12.5%) . When the algorithm was trained and tested on data collected the same day, the average performance was 43.8+/-3.6% n=10. When the training-testing separation period was five months, the average performance of the algorithm was 46.5+/-3.4% n=8. These results demonstrated that using EMG recorded and wirelessly transmitted by IMES offers a promising approach for providing intuitive, dexterous control of artificial limbs where human patients have sufficient, functional residual muscle following amputation.

  16. Crossover from capillary fingering to viscous fingering in a rough fracture

    NASA Astrophysics Data System (ADS)

    Hu, R.; Chen, Y.; Wu, D. S.

    2017-12-01

    Controlled by the competition between capillary and viscous forces, the displacement patterns of one fluid displacing another more viscous one exhibit capillary fingering, viscous fingering, and the crossover between the two. Although extensive studies have investigated viscous and capillary fingerings in porous and fractured media, a few studies focused on the crossover in rough fractures, and how viscous and capillary forces affect the crossover remains unclear. Using a transparent fracture visualization system, we studied how the competition impacts the crossover in a horizontal rough fracture. Drainage experiments of water displacing oil were conducted at seven flow rates (capillary number log10Ca ranging from -7.07 to -3.07) and four viscosity ratios (M = 1/1000, 1/500, 1/100 and 1/50). We consistently observed lower invading fluid saturations in the crossover zone. In addition, we proposed a phase diagram for the displacement patterns in a rough fracture that is consistent with similar studies in porous media. Based on real-time imaging and statistical analysis of the invasion morphology, we showed that the competition between the capillary and viscous forces is responsible for the saturation reduction in the crossover zone. In this zone, finger propagation toward the outlet (characteristic of viscous fingering) as well as void-filling in the transverse and backward directions (characteristic of capillary fingering), are both suppressed. Therefore, the invading fluid tends to occupy larger apertures with higher characteristic front velocity, promoting void-filling toward the outlet with thinner finger growth and resulting in a larger volume of defending fluid left behind.

  17. The apparent mass and mechanical impedance of the hand and the transmission of vibration to the fingers, hand, and arm

    NASA Astrophysics Data System (ADS)

    Concettoni, Enrico; Griffin, Michael

    2009-08-01

    Although hand-transmitted vibration causes injury and disease, most often evident in the fingers, the biodynamic responses of the fingers, hand, and arm are not yet well understood. A method of investigating the motion of the entire finger-hand-arm system, based on the simultaneous measurement of the biodynamic response at the driving point and the transmissibility to many points on the finger-hand-arm system, is illustrated. Fourteen male subjects participated in an experiment in which they pushed down on a vertically vibrating metal plate with their right forearm pronated and their elbow bent at 90°. The apparent mass and mechanical impedance of the finger-hand-arm system were measured for each of seven different contact conditions between the plate and the fingers and hand. Simultaneously, the vibration of the fingers, hand, and arm was measured at 41 locations using a scanning laser Doppler vibrometer. Transmissibilities showed how the vibration was transmitted along the arm and allowed the construction of spectral operating deflection shapes showing the vibration pattern of the fingers, hand, and arm for each of the seven contact conditions. The vibration patterns at critical frequencies for each contact condition have been used to explain features in the driving point biodynamic responses and the vibration behaviour of the hand-arm system. Spectral operating deflection shapes for the upper limb assist the interpretation of driving point biodynamic responses and help to advance understanding required to predict, explain, and control the various effects of hand-transmitted vibration.

  18. The plant homeodomain fingers of fission yeast Msc1 exhibit E3 ubiquitin ligase activity.

    PubMed

    Dul, Barbara E; Walworth, Nancy C

    2007-06-22

    The DNA damage checkpoint pathway governs how cells regulate cell cycle progression in response to DNA damage. A screen for suppressors of a fission yeast chk1 mutant defective in the checkpoint pathway identified a novel Schizosaccharomyces pombe protein, Msc1. Msc1 contains 3 plant homeodomain (PHD) finger motifs, characteristically defined by a C4HC3 consensus similar to RING finger domains. PHD finger domains in viral proteins and in the cellular protein kinase MEKK1 (mitogen-activated protein kinase/extracellular signal-regulated kinase kinase kinase 1) have been implicated as ubiquitin E3 protein ligases that affect protein stability. The close structural relationship of PHD fingers to RING fingers suggests that other PHD domain-containing proteins might share this activity. We show that each of the three PHD fingers of Msc1 can act as ubiquitin E3 ligases, reporting for the first time that PHD fingers from a nuclear protein exhibit E3 ubiquitin ligase activity. The function of the PHD fingers of Msc1 is needed to rescue the DNA damage sensitivity of a chk1Delta strain. Msc1 co-precipitates Rhp6, the S. pombe homologue of the human ubiquitin-conjugating enzyme Ubc2. Strikingly, deletion of msc1 confers complete suppression of the slow growth phenotype, UV and hydroxyurea sensitivities of an rhp6 deletion strain and restores deficient histone H3 methylation observed in the rhp6Delta mutant. We speculate that the target of the E3 ubiquitin ligase activity of Msc1 is likely to be a chromatin-associated protein.

  19. In vitro selection of zinc fingers with altered DNA-binding specificity.

    PubMed

    Jamieson, A C; Kim, S H; Wells, J A

    1994-05-17

    We have used random mutagenesis and phage display to alter the DNA-binding specificity of Zif268, a transcription factor that contains three zinc finger domains. Four residues in the helix of finger 1 of Zif268 that potentially mediate DNA binding were identified from an X-ray structure of the Zif268-DNA complex. A library was constructed in which these residues were randomly mutated and the Zif268 variants were fused to a truncated version of the gene III coat protein on the surface of M13 filamentous phage particles. The phage displayed the mutant proteins in a monovalent fashion and were sorted by repeated binding and elution from affinity matrices containing different DNA sequences. When the matrix contained the natural nine base pair operator sequence 5'-GCG-TGG-GCG-3', native-like zinc fingers were isolated. New finger 1 variants were found by sorting with two different operators in which the singly modified triplets, GTG and TCG, replaced the native finger 1 triplet, GCG. Overall, the selected finger 1 variants contained a preponderance of polar residues at the four sites. Interestingly, the net charge of the four residues in any selected finger never derived more that one unit from neutrality despite the fact that about half the variants contained three or four charged residues over the four sites. Measurements of the dissociation constants for two of these purified finger 1 variants by gel-shift assay showed their specificities to vary over a 10-fold range, with the greatest affinity being for the DNA binding site for which they were sorted.(ABSTRACT TRUNCATED AT 250 WORDS)

  20. Numerical Simulations and an Experimental Investigation of a Finger Seal

    NASA Technical Reports Server (NTRS)

    Braun, Minel; Pierson, Hazel; Li, H.; Dong, Dingeng

    2006-01-01

    Besides sealing, the other main goal of a successful finger seal design is to exhibit appropriate compliance to outside forces. The ability of the seal to ride or float along the rotor without rubbing or excessive heating is essential to the successful operation of the seal. The compliance of the finger must only occur in the radial plane; The seal needs to be as sturdy as possible in the axial direction. The compliant finger that moves radially outward with rotor growth and motion has to be able to ride the rotor back down as the rotor diameter recovers or the rotor moves "away". Thus there is an optimum stiffness for the finger.

  1. Sensor mount assemblies and sensor assemblies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, David H

    2012-04-10

    Sensor mount assemblies and sensor assemblies are provided. In an embodiment, by way of example only, a sensor mount assembly includes a busbar, a main body, a backing surface, and a first finger. The busbar has a first end and a second end. The main body is overmolded onto the busbar. The backing surface extends radially outwardly relative to the main body. The first finger extends axially from the backing surface, and the first finger has a first end, a second end, and a tooth. The first end of the first finger is disposed on the backing surface, and themore » tooth is formed on the second end of the first finger.« less

  2. Quantifying force application to a newborn manikin during simulated cardiopulmonary resuscitation.

    PubMed

    Solevåg, Anne Lee; Cheung, Po-Yin; Li, Elliott; Aziz, Khalid; O'Reilly, Megan; Fu, Bo; Zheng, Bin; Schmölzer, Georg

    2016-01-01

    To assess utility of the FingerTPS™ system in measuring chest compression (CC) rate and force. Five minutes of CC was performed in a neonatal manikin without (n = 29) and with (n = 30) a metronome. The FingerTPS™ force (lbs.) was compared to pressure (mmHg) in a 50-mL normal-saline bag inside the manikin. FingerTPS™ CC rate and the time until a 20% decline from baseline force and pressure were calculated. The normal-saline pressure declined earlier than the FingerTPS™ force. Metronome use did not influence CC rate, force or pressure. The FingerTPS™ can be used to measure CC rate and force.

  3. Fine finger motor skill training with exoskeleton robotic hand in chronic stroke: stroke rehabilitation.

    PubMed

    Ockenfeld, Corinna; Tong, Raymond K Y; Susanto, Evan A; Ho, Sze-Kit; Hu, Xiao-ling

    2013-06-01

    Background and Purpose. Stroke survivors often show a limited recovery in the hand function to perform delicate motions, such as full hand grasping, finger pinching and individual finger movement. The purpose of this study is to describe the implementation of an exoskeleton robotic hand together with fine finger motor skill training on 2 chronic stroke patients. Case Descriptions. Two post-stroke patients participated in a 20-session training program by integrating 10 minutes physical therapy, 20 minutes robotic hand training and 15 minutes functional training tasks with delicate objects(card, pen and coin). These two patients (A and B) had cerebrovascular accident at 6 months and 11 months respectively when enrolled in this study. Outcomes. The results showed that both patients had improvements in Fugl-Meyer assessment (FM), Action Research Arm Test (ARAT). Patients had better isolation of the individual finger flexion and extension based on the reduced muscle co-contraction from the electromyographic(EMG) signals and finger extension force after 20 sessions of training. Discussion. This preliminary study showed that by focusing on the fine finger motor skills together with the exoskeleton robotic hand, it could improve the motor recovery of the upper extremity in the fingers and hand function, which were showed in the ARAT. Future randomized controlled trials are needed to evaluate the clinical effectiveness.

  4. Recruitment of mRNA-destabilizing protein TIS11 to stress granules is mediated by its zinc finger domain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Murata, Tomiyasu; Morita, Noriyoshi; Hikita, Kiyomi

    2005-02-15

    TIS11, a member of the CCCH zinc finger protein family, was found to be distributed throughout cells with a preferential cytoplasmic localization when transiently expressed in COS-7 cells. Upon treatment with heat shock, TIS11 became localized in discrete particles in the cytoplasm of the transfectants. We showed the TIS11-positive particles to be stress granules (SGs), which are known to be formed in the cytoplasm of eukaryotic cells in response to environmental stresses. By deletion studies using the green fluorescent protein fusion system, we mapped a functional stress granule (SG) localization signal to a region containing two tandem repeats of themore » zinc finger motif of TIS11. Site-directed mutations of Tyr105/Tyr113, Gly109/Gly 114, and Phe119 in the first zinc finger motif diminished the ability of this TIS11 domain to direct SG localization. Importantly, when the zinc-chelating Cys residues in either the first or second zinc finger were mutated to Ala residues, the recruitment of the TIS11 zinc finger region to SG was significantly inhibited by the mutation and was completely abolished by the mutation in both zinc fingers. These results suggest that recruitment of TIS11 to heat shock-induced SG is governed by the tandem zinc finger domains of this protein.« less

  5. Effects of electromyography-driven robot-aided hand training with neuromuscular electrical stimulation on hand control performance after chronic stroke.

    PubMed

    Rong, Wei; Tong, Kai Yu; Hu, Xiao Ling; Ho, Sze Kit

    2015-03-01

    An electromyography-driven robot system integrated with neuromuscular electrical stimulation (NMES) was developed to investigate its effectiveness on post-stroke rehabilitation. The performance of this system in assisting finger flexion/extension with different assistance combinations was evaluated in five stroke subjects. Then, a pilot study with 20-sessions training was conducted to evaluate the training's effectiveness. The results showed that combined assistance from the NMES-robot could improve finger movement accuracy, encourage muscle activation of the finger muscles and suppress excessive muscular activities in the elbow joint. When assistances from both NMES and the robot were 50% of their maximum assistances, finger-tracking performance had the best results, with the lowest root mean square error, greater range of motion, higher voluntary muscle activations of the finger joints and lower muscle co-contraction in the finger and elbow joints. Upper limb function improved after the 20-session training, indicated by the increased clinical scores of Fugl-Meyer Assessment, Action Research Arm Test and Wolf Motor Function Test. Muscle co-contraction was reduced in the finger and elbow joints reflected by the Modified Ashworth Scale. The findings demonstrated that an electromyography-driven NMES-robot used for chronic stroke improved hand function and tracking performance. Further research is warranted to validate the method on a larger scale. Implications for Rehabilitation The hand robotics and neuromuscular electrical stimulation (NMES) techniques are still separate systems in current post-stroke hand rehabilitation. This is the first study to investigate the combined effects of the NMES and robot on hand rehabilitation. The finger tracking performance was improved with the combined assistance from the EMG-driven NMES-robot hand system. The assistance from the robot could improve the finger movement accuracy and the assistance from the NMES could reduce the muscle co-contraction on finger and elbow joints. The upper limb functions were improved on chronic stroke patients after the pilot study of 20-session hand training with the combined assistance from the EMG-driven NMES-robot. The muscle spasticity on finger and elbow joints was reduced after the training.

  6. Dyscalculia: neuroscience and education

    PubMed Central

    Kaufmann, Liane

    2010-01-01

    Background Developmental dyscalculia is a heterogeneous disorder with largely dissociable performance profiles. Though our current understanding of the neurofunctional foundations of (adult) numerical cognition has increased considerably during the past two decades, there are still many unanswered questions regarding the developmental pathways of numerical cognition. Most studies on developmental dyscalculia are based upon adult calculation models which may not provide an adequate theoretical framework for understanding and investigating developing calculation systems. Furthermore, the applicability of neuroscience research to pedagogy has, so far, been limited. Purpose After providing an overview of current conceptualisations of numerical cognition and developmental dyscalculia, the present paper (1) reviews recent research findings that are suggestive of a neurofunctional link between fingers (finger gnosis, finger-based counting and calculation) and number processing, and (2) takes the latter findings as an example to discuss how neuroscience findings may impact on educational understanding and classroom interventions. Sources of evidence Finger-based number representations and finger-based calculation have deep roots in human ontology and phylogeny. Recently, accumulating empirical evidence supporting the hypothesis of a neurofunctional link between fingers and numbers has emerged from both behavioural and brain imaging studies. Main argument Preliminary but converging research supports the notion that finger gnosis and finger use seem to be related to calculation proficiency in elementary school children. Finger-based counting and calculation may facilitate the establishment of mental number representations (possibly by fostering the mapping from concrete non-symbolic to abstract symbolic number magnitudes), which in turn seem to be the foundations for successful arithmetic achievement. Conclusions Based on the findings illustrated here, it is plausible to assume that finger use might be an important and complementary aid (to more traditional pedagogical methods) to establish mental number representations and/or to facilitate learning to count and calculate. Clearly, future prospective studies are needed to investigate whether the explicit use of fingers in early mathematics teaching might prove to be beneficial for typically developing children and/or might support the mapping from concrete to abstract number representations in children with and without developmental dyscalculia. PMID:21258625

  7. Dyscalculia: neuroscience and education.

    PubMed

    Kaufmann, Liane

    2008-06-01

    BACKGROUND: Developmental dyscalculia is a heterogeneous disorder with largely dissociable performance profiles. Though our current understanding of the neurofunctional foundations of (adult) numerical cognition has increased considerably during the past two decades, there are still many unanswered questions regarding the developmental pathways of numerical cognition. Most studies on developmental dyscalculia are based upon adult calculation models which may not provide an adequate theoretical framework for understanding and investigating developing calculation systems. Furthermore, the applicability of neuroscience research to pedagogy has, so far, been limited. PURPOSE: After providing an overview of current conceptualisations of numerical cognition and developmental dyscalculia, the present paper (1) reviews recent research findings that are suggestive of a neurofunctional link between fingers (finger gnosis, finger-based counting and calculation) and number processing, and (2) takes the latter findings as an example to discuss how neuroscience findings may impact on educational understanding and classroom interventions. SOURCES OF EVIDENCE: Finger-based number representations and finger-based calculation have deep roots in human ontology and phylogeny. Recently, accumulating empirical evidence supporting the hypothesis of a neurofunctional link between fingers and numbers has emerged from both behavioural and brain imaging studies. MAIN ARGUMENT: Preliminary but converging research supports the notion that finger gnosis and finger use seem to be related to calculation proficiency in elementary school children. Finger-based counting and calculation may facilitate the establishment of mental number representations (possibly by fostering the mapping from concrete non-symbolic to abstract symbolic number magnitudes), which in turn seem to be the foundations for successful arithmetic achievement. CONCLUSIONS: Based on the findings illustrated here, it is plausible to assume that finger use might be an important and complementary aid (to more traditional pedagogical methods) to establish mental number representations and/or to facilitate learning to count and calculate. Clearly, future prospective studies are needed to investigate whether the explicit use of fingers in early mathematics teaching might prove to be beneficial for typically developing children and/or might support the mapping from concrete to abstract number representations in children with and without developmental dyscalculia.

  8. Stabilization of posture by precision touch of the index finger with rigid and flexible filaments

    NASA Technical Reports Server (NTRS)

    Lackner, J. R.; Rabin, E.; DiZio, P.

    2001-01-01

    Light touch of the index finger with a stationary surface at non-mechanically supportive force levels (<100 g) greatly attenuates the body sway of standing subjects. In three experiments, we evaluated the properties of finger contact and of the contacted object necessary to produce postural stabilization in subjects standing heel-to-toe with eyes closed, as well as how accurately hand position can be controlled. Experiment 1 involved finger contact with flexible filaments of different bending strengths, a flat surface, and an imagined spatial position. Contact with the flat surface was most effective in attenuating sway; the flexible filaments were much less effective but still significantly better than imagined contact. Experiment 2 compared the effectiveness of finger contact with a flexible filament, a rigid filament of the same diameter, a flat surface, and an imagined spatial position. The rigid filament and flat surface conditions were equally effective in attenuating body sway and were greatly superior to contact with the flexible filament, which was superior to imagined contact. Experiment 3 included five conditions: arms by sides; finger "contact" with an imagined spatial position; finger contact with a flat surface; finger contact with a flexible filament attempting to maintain it bent; and contact with the flexible filament attempting not to bend it. The arms by sides and finger "contact" with an imagined position conditions did not differ significantly; all three conditions involving actual finger contact showed significantly less center of pressure and hand sway, but contact with the flat surface was most effective in attenuating both postural and hand displacement. In all three experiments, the level of force applied in fingertip contact conditions was far below that necessary to provide mechanical stabilization. Our findings indicate that: (1) stimulation of a small number of receptors in the fingertip is adequate to allow stabilization of sway, (2) fingertip force levels as low as 5-10 g provide some stabilization, (3) contact with a stationary spatial referent is most effective, and (4) independent control of arm and torso occurs when finger contact is allowed.

  9. The effect of nerve blockade on forearm and finger skin blood flow during body heating and cooling.

    PubMed

    Saumet, J L; Degoute, C S; Saumet, M; Abraham, P

    1992-08-01

    To determine the role of the active cutaneous vasodilatator response in forearm and finger skin, direct assessment of only skin blood flow was performed before and after musculocutaneous and median nerve blockade during whole body heating and cooling. Forearm laser Doppler flow (LDF forearm), forearm heat thermal clearance (HTC forearm), and finger laser Doppler flow (LDF finger) were monitored in the nerve blocked skin and contralateral untreated skin (control). In the pre-blockade period, no significant differences were found between experimental and control arm skin. After nerve block a significant increase occurred only in LDF finger, which rose from 4.3 +/- 0.6 to 6.0 +/- 0.5 volts (p less than 0.05). During whole body heating LDF forearm and HTC forearm increased significantly on both arms. The increase in LDF forearm was greater (p less than 0.05) in control (18.3 +/- 1.2 volts) than in nerve blocked skin (14.6 +/- 1.8 volts) and occurred earlier. The same tendency was observed in HTC forearm between nerve blocked skin (0.522 +/- 0.06 W.m-1.degrees C-1) and control 0.671 +/- 0.037 W.m-1.degrees C-1) (NS). LDF raise up to 6.6 +/- 0.5 and 6.8 +/- 0.5 volts in the blocked finger and in the control respectively. During cooling LDF finger in the control decreased to 1.3 +/- 0.1 volt and was significantly (p less than 0.05) lower than in the resting period, and lower than that in the nerve blocked finger (3.4 +/- 0.8 volts) (p less than 0.05). We conclude that the active vasodilatator system plays an important role as far as the timing and the amplitude of the cutaneous vasodilatator response to whole body heating in the forearm but not in the finger. At thermal neutrality, the vascular vasoconstrictor tone is high to the finger but not to the forearm. The vasoconstrictor response to cooling occurred only in the finger.

  10. Evaluation of finger plate and flat plate connection design.

    DOT National Transportation Integrated Search

    2016-01-01

    This project investigates the cause(s) of premature deterioration of MoDOT finger plate and flat plate expansion devices : under high traffic volumes and then uses that information to design new Load and Resistance Factor Design (LRFD) : finger plate...

  11. Tool-specific performance of vibration-reducing gloves for attenuating fingers-transmitted vibration

    PubMed Central

    Welcome, Daniel E.; Dong, Ren G.; Xu, Xueyan S.; Warren, Christopher; McDowell, Thomas W.

    2016-01-01

    BACKGROUND Fingers-transmitted vibration can cause vibration-induced white finger. The effectiveness of vibration-reducing (VR) gloves for reducing hand transmitted vibration to the fingers has not been sufficiently examined. OBJECTIVE The objective of this study is to examine tool-specific performance of VR gloves for reducing finger-transmitted vibrations in three orthogonal directions (3D) from powered hand tools. METHODS A transfer function method was used to estimate the tool-specific effectiveness of four typical VR gloves. The transfer functions of the VR glove fingers in three directions were either measured in this study or during a previous study using a 3D laser vibrometer. More than seventy vibration spectra of various tools or machines were used in the estimations. RESULTS When assessed based on frequency-weighted acceleration, the gloves provided little vibration reduction. In some cases, the gloves amplified the vibration by more than 10%, especially the neoprene glove. However, the neoprene glove did the best when the assessment was based on unweighted acceleration. The neoprene glove was able to reduce the vibration by 10% or more of the unweighted vibration for 27 out of the 79 tools. If the dominant vibration of a tool handle or workpiece was in the shear direction relative to the fingers, as observed in the operation of needle scalers, hammer chisels, and bucking bars, the gloves did not reduce the vibration but increased it. CONCLUSIONS This study confirmed that the effectiveness for reducing vibration varied with the gloves and the vibration reduction of each glove depended on tool, vibration direction to the fingers, and finger location. VR gloves, including certified anti-vibration gloves do not provide much vibration reduction when judged based on frequency-weighted acceleration. However, some of the VR gloves can provide more than 10% reduction of the unweighted vibration for some tools or workpieces. Tools and gloves can be matched for better effectiveness for protecting the fingers. PMID:27867313

  12. Involuntary Neuromuscular Coupling between the Thumb and Finger of Stroke Survivors during Dynamic Movement

    PubMed Central

    Jones, Christopher L.; Kamper, Derek G.

    2018-01-01

    Finger–thumb coordination is crucial to manual dexterity but remains incompletely understood, particularly following neurological injury such as stroke. While being controlled independently, the index finger and thumb especially must work in concert to perform a variety of tasks requiring lateral or palmar pinch. The impact of stroke on this functionally critical sensorimotor control during dynamic tasks has been largely unexplored. In this study, we explored finger–thumb coupling during close–open pinching motions in stroke survivors with chronic hemiparesis. Two types of perturbations were applied randomly to the index with a novel Cable-Actuated Finger Exoskeleton: a sudden joint acceleration stretching muscle groups of the index finger and a sudden increase in impedance in selected index finger joint(s). Electromyographic signals for specific thumb and index finger muscles, thumb tip trajectory, and index finger joint angles were recorded during each trial. Joint angle perturbations invoked reflex responses in the flexor digitorum superficialis (FDS), first dorsal interossei (FDI), and extensor digitorum communis muscles of the index finger and heteronymous reflex responses in flexor pollicis brevis of the thumb (p < 0.017). Phase of movement played a role as a faster peak reflex response was observed in FDI during opening than during closing (p < 0.002) and direction of perturbations resulted in shorter reflex times for FDS and FDI (p < 0.012) for extension perturbations. Surprisingly, when index finger joint impedance was suddenly increased, thumb tip movement was substantially increased, from 2 to 10 cm (p < 0.001). A greater effect was seen during the opening phase (p < 0.044). Thus, involuntary finger–thumb coupling was present during dynamic movement, with perturbation of the index finger impacting thumb activity. The degree of coupling modulated with the phase of motion. These findings reveal a potential mechanism for direct intervention to improve poststroke hand mobility and provide insight on prospective neurologically oriented therapies. PMID:29545767

  13. Factors affecting healing and survival after finger amputations in patients with digital artery occlusive disease.

    PubMed

    Landry, Gregory J; McClary, Ashley; Liem, Timothy K; Mitchell, Erica L; Azarbal, Amir F; Moneta, Gregory L

    2013-05-01

    Finger amputations are typically performed as distal as possible to preserve maximum finger length. Failure of primary amputation leads to additional procedures, which could potentially be avoided if a more proximal amputation was initially performed. The effect of single versus multiple procedures on morbidity and mortality is not known. We evaluated factors that predicted primary healing and the effects of secondary procedures on survival. Patients undergoing finger amputations from 1995 to 2011 were evaluated for survival with uni- and multivariate analysis of demographic data and preoperative vascular laboratory studies to assess factors influencing primary healing. Seventy-six patients underwent 175 finger amputations (range 1 to 6 fingers per patient). Forty-one percent had diabetes, 33% had nonatherosclerotic digital artery disease, and 29% were on dialysis. Sex distribution was equal. Primary healing occurred in 78.9%, with the remainder requiring revisions. By logistic regression analysis, nonatherosclerotic digital artery disease was associated with failure of primary healing (odds ratio = 7.5; 95% confidence interval, 1.03 to 54; P = .047). Digital photoplethysmography did not predict primary healing. The overall healing of primary and secondary finger amputations was 96.0%. The mean survival after the initial finger amputation was 34.3 months and did not differ between patients undergoing single (35.6 months) versus multiple procedures (33.6 months). Dialysis dependence was associated with decreased survival (hazard ratio = 2.9; 95% confidence interval, 1.13 to 7.25; P = .026). Failure of primary healing is associated with the presence of nonatherosclerotic digital artery disease and is not predicted by digital photoplethysmographic studies. Dialysis dependence is associated with decreased survival in patients with finger amputations, but failure of primary healing does not adversely affect survival. A strategy of aggressive preservation of finger length is appropriate for most patients. Copyright © 2013. Published by Elsevier Inc.

  14. Control of an optimal finger exoskeleton based on continuous joint angle estimation from EMG signals.

    PubMed

    Ngeo, Jimson; Tamei, Tomoya; Shibata, Tomohiro; Orlando, M F Felix; Behera, Laxmidhar; Saxena, Anupam; Dutta, Ashish

    2013-01-01

    Patients suffering from loss of hand functions caused by stroke and other spinal cord injuries have driven a surge in the development of wearable assistive devices in recent years. In this paper, we present a system made up of a low-profile, optimally designed finger exoskeleton continuously controlled by a user's surface electromyographic (sEMG) signals. The mechanical design is based on an optimal four-bar linkage that can model the finger's irregular trajectory due to the finger's varying lengths and changing instantaneous center. The desired joint angle positions are given by the predictive output of an artificial neural network with an EMG-to-Muscle Activation model that parameterizes electromechanical delay (EMD). After confirming good prediction accuracy of multiple finger joint angles we evaluated an index finger exoskeleton by obtaining a subject's EMG signals from the left forearm and using the signal to actuate a finger on the right hand with the exoskeleton. Our results show that our sEMG-based control strategy worked well in controlling the exoskeleton, obtaining the intended positions of the device, and that the subject felt the appropriate motion support from the device.

  15. You can count on the motor cortex: finger counting habits modulate motor cortex activation evoked by numbers.

    PubMed

    Tschentscher, Nadja; Hauk, Olaf; Fischer, Martin H; Pulvermüller, Friedemann

    2012-02-15

    The embodied cognition framework suggests that neural systems for perception and action are engaged during higher cognitive processes. In an event-related fMRI study, we tested this claim for the abstract domain of numerical symbol processing: is the human cortical motor system part of the representation of numbers, and is organization of numerical knowledge influenced by individual finger counting habits? Developmental studies suggest a link between numerals and finger counting habits due to the acquisition of numerical skills through finger counting in childhood. In the present study, digits 1 to 9 and the corresponding number words were presented visually to adults with different finger counting habits, i.e. left- and right-starters who reported that they usually start counting small numbers with their left and right hand, respectively. Despite the absence of overt hand movements, the hemisphere contralateral to the hand used for counting small numbers was activated when small numbers were presented. The correspondence between finger counting habits and hemispheric motor activation is consistent with an intrinsic functional link between finger counting and number processing. Copyright © 2011 Elsevier Inc. All rights reserved.

  16. Non-contact finger vein acquisition system using NIR laser

    NASA Astrophysics Data System (ADS)

    Kim, Jiman; Kong, Hyoun-Joong; Park, Sangyun; Noh, SeungWoo; Lee, Seung-Rae; Kim, Taejeong; Kim, Hee Chan

    2009-02-01

    Authentication using finger vein pattern has substantial advantage than other biometrics. Because human vein patterns are hidden inside the skin and tissue, it is hard to forge vein structure. But conventional system using NIR LED array has two drawbacks. First, direct contact with LED array raise sanitary problem. Second, because of discreteness of LEDs, non-uniform illumination exists. We propose non-contact finger vein acquisition system using NIR laser and Laser line generator lens. Laser line generator lens makes evenly distributed line laser from focused laser light. Line laser is aimed on the finger longitudinally. NIR camera was used for image acquisition. 200 index finger vein images from 20 candidates are collected. Same finger vein pattern extraction algorithm was used to evaluate two sets of images. Acquired images from proposed non-contact system do not show any non-uniform illumination in contrary with conventional system. Also results of matching are comparable to conventional system. We developed Non-contact finger vein acquisition system. It can prevent potential cross contamination of skin diseases. Also the system can produce uniformly illuminated images unlike conventional system. With the benefit of non-contact, proposed system shows almost equivalent performance compared with conventional system.

  17. Optoacoustic angiography of peripheral vasculature

    NASA Astrophysics Data System (ADS)

    Ermilov, Sergey; Su, Richard; Zamora, Mario; Hernandez, Travis; Nadvoretsky, Vyacheslav; Oraevsky, Alexander

    2012-02-01

    We developed a new optoacoustic microangiography system (OmAS) intended for in-vivo vascular imaging of a human finger. The system employs an arc-shaped acoustic array that is rotated 360 degrees around the finger providing optoacoustic data necessary for tomographic reconstruction of the three-dimensional images of a finger. A near-infrared Q-switched laser is used to generate optoacoustic signals with increased contrast of blood vessels. The laser is coupled through two randomized fiberoptic bundles oriented in orthogonal optoacoustic mode. To demonstrate OmAS capabilities, we present a time-series of optoacoustic images of a human finger taken after the hypothermia stress test. The images show a detailed vascular anatomy of a finger down to the capillary level. A series of quick 30s scans allowed us to visualize the thermoregulatory response within the studied finger as it was manifested via vasomotor activity during the hypothermia recovery. We propose that the developed system can be used for diagnostics of various medical conditions that are manifested in change of the peripheral (finger) blood flow. Examples of the medical conditions that could be diagnosed and staged using the OmAS include the peripheral arterial disease (PAD), thrombosis, frostbite, and traumas.

  18. A transition in the viscous fingering instability in miscible fluids

    NASA Astrophysics Data System (ADS)

    Videbaek, Thomas; Nagel, Sidney R.

    2017-11-01

    The viscous fingering instability in a quasi-two dimensional Hele-Shaw cell is an example of complex structure formation from benign initial conditions. When the invading fluid has the lesser viscosity, the interface between the two fluids is unstable to finger formation. Here, we study the instability between pairs of miscible fluids in a circular cell with fluid injected at its center. As the injection rate is decreased, diffusion will smooth out the discontinuity in the gap-averaged viscosity at the interface between the fluids. At high injection rates (i.e., high Péclet number, Pe), fingering is associated with three-dimensional structure within the gap between the confining plates. On lowering Pe, we find a sharp transition in the finger morphology at a critical value, Pec (ηi /ηo) 1 / 2 , with ηi (ηo) being the viscosity of the inner (outer) fluid; at this point, the width of the fingers jumps, the length of the fingers shrinks towards zero and the three-dimensional structure goes from half filling to fully filling the gap. Thus, by controlling the viscosity contrast at the interface, one can alter and even completely suppress the instability.

  19. Identification of Stimulated Sites Using Artificial Neural Networks Based on Transcranial Magnetic Stimulation-Elicited Motor Evoked Potentials and Finger Forces

    NASA Astrophysics Data System (ADS)

    Fukuda, Hiroshi; Odagaki, Masato; Hiwaki, Osamu

    Motor evoked potentials (MEPs) elicited by transcranial magnetic stimulation (TMS) over the primary motor cortex (M1) vary in their amplitude from trial to trial. To investigate the functions of motor cortex by TMS, it is necessary to confirm the causal relationship between stimulated sites and variable MEPs. We created artificial neural networks to classify sets of variable MEP signals and finger forces into the corresponding stimulated sites. We conducted TMS at three different positions over M1 and measured MEPs of hand and forearm muscles and forces of the index finger in four subjects. We estimated the sites within motor cortex stimulated by TMS based on cortical columnar structure and nerve excitation properties. Finally, we tried to classify the various MEPs and finger forces into three groups using artificial neural networks. MEPs and finger forces varied from trial to trial, even if the stimulating coil was fixed on the subject's head. Our proposed neural network was able to identify the MEPs and finger forces with the corresponding stimulated sites in M1. We proposed the artificial neural networks to confirm the TMS-stimulated sites using various MEPs and evoked finger forces.

  20. Multi-scale recordings for neuroprosthetic control of finger movements.

    PubMed

    Baker, Justin; Bishop, William; Kellis, Spencer; Levy, Todd; House, Paul; Greger, Bradley

    2009-01-01

    We trained a rhesus monkey to perform individuated and combined finger flexions and extensions of the thumb, index, and middle finger. A Utah Electrode Array (UEA) was implanted into the hand region of the motor cortex contralateral to the monkey's trained hand. We also implanted a microwire electrocorticography grid (microECoG) epidurally so that it covered the UEA. The microECoG grid spanned the arm and hand regions of both the primary motor and somatosensory cortices. Previously this monkey had Implantable MyoElectric Sensors (IMES) surgically implanted into the finger muscles of the monkey's forearm. Action potentials (APs), local field potentials (LFPs), and microECoG signals were recorded from wired head-stage connectors for the UEA and microECoG grids, while EMG was recorded wirelessly. The monkey performed a finger flexion/extension task while neural and EMG data were acquired. We wrote an algorithm that uses the spike data from the UEA to perform a real-time decode of the monkey's finger movements. Also, analyses of the LFP and microECoG data indicate that these data show trial-averaged differences between different finger movements, indicating the data are potentially decodeable.

  1. Reductions in finger blood flow induced by 125-Hz vibration: effect of location of contact with vibration.

    PubMed

    Ye, Ying; Griffin, Michael J

    2016-04-01

    This study investigated whether the reductions in finger blood flow induced by 125-Hz vibration applied to different locations on the hand depend on thresholds for perceiving vibration at these locations. Subjects attended three sessions during which vibration was applied to the right index finger, the right thenar eminence, or the left thenar eminence. Absolute thresholds for perceiving vibration at these locations were determined. Finger blood flow in the middle finger of both hands was then measured at 30-s intervals during five successive 5-min periods: (i) pre-exposure, (ii) pre-exposure with 2-N force, (iii) 2-N force with vibration, (iv) post-exposure with 2-N force, (v) recovery. During period (iii), vibration was applied at 15 dB above the absolute threshold for perceiving vibration at the right thenar eminence. Vibration at all three locations reduced finger blood flow on the exposed and unexposed hand, with greater reductions when vibrating the finger. Vibration-induced vasoconstriction was greatest for individuals with low thresholds and locations of excitation with low thresholds. Differences in vasoconstriction between subjects and between locations are consistent with the Pacinian channel mediating both absolute thresholds and vibration-induced vasoconstriction.

  2. Artificial dexterous hand

    NASA Technical Reports Server (NTRS)

    Lee, Sukhan (Inventor)

    1990-01-01

    An artificial dexterous hand is provided for grasping and manipulating objects. The hand includes left and right thumbs that are operatively connected to an engagement assembly which causes movement of the left and right thumbs. The left thumb has a left thumb base and is movable about three separate first left thumb axes which run through the left thumb base. Correspondingly, the right thumb has a right thumb base and is movable about three separate first right thumb axes which run through the right thumb base. The engagement assembly has a gear assembly which is operatively connected to a motor assembly. Upon actuation by the motor assembly, the gear assembly causes movement of the left and right thumbs about the first left thumb axes and first right thumb axes respectively. The hand can also have a center finger which is operatively connected to the engagement assembly and which is interposed between the left and right thumbs. The finger has a finger base and is movable about two separate first finger axes running through the finger base. Therefore, upon actuation by the motor assembly, the gear assembly will also cause movement of the finger about the first finger axes.

  3. A Comparison of Pulse-Oximetry, Near-Infrared Spectroscopy (NIRS), and Gas Sensors for In-Cockpit Hypoxia Detection

    DTIC Science & Technology

    2012-08-29

    Pulse Oximetry: Arterial oxygen saturation (SpO2) at the index finger on the left hand was measured with a finger oximeter (Model 3900 P, Datex...minutes or until their finger O2 saturation levels dropped below 50%. Oxygen saturation was measured via the left index finger with a pulse oximeter ... saturation . Pulse oximeters have two light emitting diodes, using red (600-750 nm) and near infrared (850-1000 nm) light that penetrates the skin

  4. Molecular and functional characterization of two drought-induced zinc finger proteins, ZmZnF1 and ZmZnF2 from maize kernels

    USDA-ARS?s Scientific Manuscript database

    We have isolated two cDNA clones encoding Zinc Finger proteins, designated as ZmZnF1 and ZmZnF2, from water-stressed maize kernels. Sequence analyses indicates that ZmZnF1 is homologous to the A20/AN1-type zinc finger protein and contains the zinc finger motif of Cx2–Cx10–CxCx4Cx2Hx5HxC. Whereas ZmZ...

  5. Finger-Circumference-Measuring Device

    NASA Technical Reports Server (NTRS)

    Le, Suy

    1995-01-01

    Easy-to-use device quickly measures circumference of finger (including thumb) on human hand. Includes polytetrafluoroethylene band 1/8 in. wide, bent into loop and attached to tab that slides on scale graduated in millimeters. Sliding tab preloaded with constant-force tension spring, which pulls tab toward closure of loop. Designed to facilitate measurements at various points along fingers to obtain data for studies of volumetric changes of fingers in microgravity. Also used in normal Earth gravity studies of growth and in assessment of diseases like arthritis.

  6. Cardiovascular regulation during head-up tilt in healthy 20-30-year-old and 70-75-year-old men.

    PubMed

    Gabbett, T J; Weston, S B; Barrett, R S; Gass, G C

    2001-02-01

    This study compared the heart rate, finger arterial pressure (AP) and electromyographic (EMG) activity of selected anti-gravity muscles during the initial and prolonged phases of orthostatic stress in healthy young and older men. Beat-by-beat recordings of heart rate, finger systolic pressure, diastolic pressure and mean AP were made during supine rest and 5 min of 90 degrees head-up tilt (HUT) in 18 young (23+/-1 years) and 15 older (73+/-1 years) men. The EMG activity of the soleus, tibialis anterior and vastus medialis muscles was recorded. During the first 30 s following 90 degrees HUT (immediate response), the young men exhibited significant (P<0.05) decreases in finger systolic pressure, diastolic pressure and mean AP, followed by a sustained increase in finger AP during the 5 min following 90 degrees HUT (prolonged response). The immediate and prolonged finger AP and diastolic pressure responses were not significantly different (P>0.05) from the values at supine rest for the older men. The mean root mean square EMG activity of the soleus, tibialis anterior and vastus medialis muscles during 90 degrees HUT was not significantly different (P>0.05) from that at supine rest for either group. These results demonstrate that, when compared with healthy older men, young men show larger reductions in finger AP during the initial phase of orthostatic stress. However, during the prolonged phase of orthostatic stress, older men maintain resting finger AP, whereas young men demonstrate a reflex overshoot in finger AP. Finally, differences in lower-limb anti-gravity muscle activation do not account for the contrasting finger AP responses of healthy young and older men.

  7. Fingerprint Recognition with Identical Twin Fingerprints

    PubMed Central

    Yang, Xin; Tian, Jie

    2012-01-01

    Fingerprint recognition with identical twins is a challenging task due to the closest genetics-based relationship existing in the identical twins. Several pioneers have analyzed the similarity between twins' fingerprints. In this work we continue to investigate the topic of the similarity of identical twin fingerprints. Our study was tested based on a large identical twin fingerprint database that contains 83 twin pairs, 4 fingers per individual and six impressions per finger: 3984 (83*2*4*6) images. Compared to the previous work, our contributions are summarized as follows: (1) Two state-of-the-art fingerprint identification methods: P071 and VeriFinger 6.1 were used, rather than one fingerprint identification method in previous studies. (2) Six impressions per finger were captured, rather than just one impression, which makes the genuine distribution of matching scores more realistic. (3) A larger sample (83 pairs) was collected. (4) A novel statistical analysis, which aims at showing the probability distribution of the fingerprint types for the corresponding fingers of identical twins which have same fingerprint type, has been conducted. (5) A novel analysis, which aims at showing which finger from identical twins has higher probability of having same fingerprint type, has been conducted. Our results showed that: (a) A state-of-the-art automatic fingerprint verification system can distinguish identical twins without drastic degradation in performance. (b) The chance that the fingerprints have the same type from identical twins is 0.7440, comparing to 0.3215 from non-identical twins. (c) For the corresponding fingers of identical twins which have same fingerprint type, the probability distribution of five major fingerprint types is similar to the probability distribution for all the fingers' fingerprint type. (d) For each of four fingers of identical twins, the probability of having same fingerprint type is similar. PMID:22558204

  8. Comparison of oxygen saturation values obtained from fingers on physically restrained or unrestrained sides of the body.

    PubMed

    Korhan, Esra Akin; Yönt, Gülendam Hakverdioğlu; Khorshid, Leyla

    2011-01-01

    The aim of this study was to compare semiexperimentally the pulse oximetry values obtained from a finger on restrained or unrestrained sides of the body. The pulse oximeter provides a noninvasive measurement of the oxygen saturation of hemoglobin in arterial blood. One of the procedures most frequently applied to patients in intensive care units is the application of physical restraint. Circulation problems are the most important complication in patients who are physically restrained. Evaluation of oxygen saturation from body parts in which circulation is impeded or has deteriorated can cause false results. The research sample consisted of 30 hospitalized patients who participated in the study voluntarily and who were concordant with the inclusion criteria of the study. Patient information and patient follow-up forms were used for data collection. Pulse oximetry values were measured simultaneously using OxiMax Nellcor finger sensors from fingers on the restrained and unrestrained sides of the body. Numeric and percentile distributions were used in evaluating the sociodemographic properties of patients. A significant difference was found between the oxygen saturation values obtained from a finger of an arm that had been physically restrained and a finger of an arm that had not been physically restrained. The mean oxygen saturation value measured from a finger of an arm that had been physically restrained was found to be 93.40 (SD, 2.97), and the mean oxygen saturation value measured from a finger of an arm that had not been physically restrained was found to be 95.53 (SD, 2.38). The results of this study indicate that nurses should use a finger of an arm that is not physically restrained when evaluating oxygen saturation values to evaluate them correctly.

  9. A flap based on the plantar digital artery arch branch to improve appearance of reconstructed fingers: Anatomical and clinical application.

    PubMed

    Tang, Lin-Feng; Ju, Ji-Hui; Liu, Yue-Fei; Lan, Bo; Hou, Rui-Xing

    2018-02-01

    To investigate blood supply features of the flap based on the plantar digital artery arch and arch branch artery, and the treatment of outcomes of reconstructed fingers by the plantar digital artery arch branch island flap. Eight fresh foot specimens were employed with red emulsion infusion and microdissection. The vascular organization was observed in the second toe, such as initiation site, the course, and the number of the plantar digital artery arch branch. There were 15 fingers of 13 patients (8 males and 5 females) with finger defects accompanied by toe transfer, using the plantar digital artery arch branch flap inserted in the neck of the second toe to correct the appearance defect caused by a narrow "neck" and a bulbous tip. The intact plantar digital arches were identified in all specimens. The plantar digital artery arch had 5 branches. The range of external diameter of the arch branch was 0.4-0.6 mm. All the plantar digital artery arch branch island flaps and the reconstructed fingers survived. These cases were conducted with a follow-up period for 3-18 months (average, 9 months). All the plantar digital artery arch branch island flaps and reconstructed fingers demonstrated a satisfactory appearance and favorable sense function. The reconstructed finger-tip characteristic was good, with no obvious scar hyperplasia. The range of flexion and extension of reconstructed fingers was favorable as well. The plantar digital artery arch and arch branch artery possess regular vasa vasorum and abundant vascularity. A flap based on the plantar digital artery arch branch is an ideal selection for plastic surgery of reconstructed fingers. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  10. Models of brachial to finger pulse wave distortion and pressure decrement.

    PubMed

    Gizdulich, P; Prentza, A; Wesseling, K H

    1997-03-01

    To model the pulse wave distortion and pressure decrement occurring between brachial and finger arteries. Distortion reversion and decrement correction were also our aims. Brachial artery pressure was recorded intra-arterially and finger pressure was recorded non-invasively by the Finapres technique in 53 adult human subjects. Mean pressure was subtracted from each pressure waveform and Fourier analysis applied to the pulsations. A distortion model was estimated for each subject and averaged over the group. The average inverse model was applied to the full finger pressure waveform. The pressure decrement was modelled by multiple regression on finger systolic and diastolic levels. Waveform distortion could be described by a general, frequency dependent model having a resonance at 7.3 Hz. The general inverse model has an anti-resonance at this frequency. It converts finger to brachial pulsations thereby reducing average waveform distortion from 9.7 (s.d. 3.2) mmHg per sample for the finger pulse to 3.7 (1.7) mmHg for the converted pulse. Systolic and diastolic level differences between finger and brachial arterial pressures changed from -4 (15) and -8 (11) to +8 (14) and +8 (12) mmHg, respectively, after inverse modelling, with pulse pressures correct on average. The pressure decrement model reduced both the mean and the standard deviation of systolic and diastolic level differences to 0 (13) and 0 (8) mmHg. Diastolic differences were thus reduced most. Brachial to finger pulse wave distortion due to wave reflection in arteries is almost identical in all subjects and can be modelled by a single resonance. The pressure decrement due to flow in arteries is greatest for high pulse pressures superimposed on low means.

  11. Multi-finger synergies and the muscular apparatus of the hand.

    PubMed

    Cuadra, Cristian; Bartsch, Angelo; Tiemann, Paula; Reschechtko, Sasha; Latash, Mark L

    2018-05-01

    We explored whether the synergic control of the hand during multi-finger force production tasks depends on the hand muscles involved. Healthy subjects performed accurate force production tasks and targeted force pulses while pressing against loops positioned at the level of fingertips, middle phalanges, and proximal phalanges. This varied the involvement of the extrinsic and intrinsic finger flexors. The framework of the uncontrolled manifold (UCM) hypothesis was used to analyze the structure of inter-trial variance, motor equivalence, and anticipatory synergy adjustments prior to the force pulse in the spaces of finger forces and finger modes (hypothetical finger-specific control signals). Subjects showed larger maximal force magnitudes at the proximal site of force production. There were synergies stabilizing total force during steady-state phases across all three sites of force production; no differences were seen across the sites in indices of structure of variance, motor equivalence, or anticipatory synergy adjustments. Indices of variance, which did not affect the task (within the UCM), correlated with motor equivalent motion between the steady states prior to and after the force pulse; in contrast, variance affecting task performance did not correlate with non-motor equivalent motion. The observations are discussed within the framework of hierarchical control with referent coordinates for salient effectors at each level. The findings suggest that multi-finger synergies are defined at the level of abundant transformation between the low-dimensional hand level and higher dimensional finger level while being relatively immune to transformations between the finger level and muscle level. The results also support the scheme of control with two classes of neural variables that define referent coordinates and gains in back-coupling loops between hierarchical control levels.

  12. The effect of keyboard key spacing on typing speed, error, usability, and biomechanics, Part 2: Vertical spacing.

    PubMed

    Pereira, Anna; Hsieh, Chih-Ming; Laroche, Charles; Rempel, David

    2014-06-01

    The objective was to evaluate the effects of vertical key spacing on a conventional computer keyboard on typing speed, percentage error, usability, forearm muscle activity, and wrist posture for both females with small fingers and males with large fingers. Part I evaluated primarily horizontal key spacing and found that for male typists with large fingers, productivity and usability were similar for spacings of 17, 18, and 19 mm but were reduced for spacings of 16 mm. Few other key spacing studies are available, and the international standards that specify the spacing between keys on a keyboard have been mainly guided by design convention. Experienced female typists (n = 26) with small fingers (middle finger length < or = 7.71 cm or finger breadth of < or = 1.93 cm) and male typists (n = 26) with large fingers (middle finger length > or = 8.37 cm or finger breadth of > or = 2.24 cm) typed on five keyboards that differed primarily in vertical key spacing (17 x 18, 17 x 17, 17 x 16, 17 x 15.5, and 18 x 16 mm) while typing speed, error, fatigue, preference, forearm muscle activity, and wrist posture were recorded. Productivity and usability ratings were significantly worse for the keyboard with 15.5 mm vertical spacing compared to the other keyboards for both groups.There were few significant differences on usability ratings between the other keyboards. Reducing vertical key spacing,from 18 to 17 to 16 mm, had no significant effect on productivity or usability. The findings support the design of keyboards with vertical key spacings of 16, 17, or 18 mm. These findings may influence keyboard design and standards.

  13. Density Driven Removal of Sediment from a Buoyant Muddy Plume

    NASA Astrophysics Data System (ADS)

    Rouhnia, M.; Strom, K.

    2014-12-01

    Experiments were conducted to study the effect of settling driven instabilities on sediment removal from hypopycnal plumes. Traditional approaches scale removal rates with particle settling velocity however, it has been suggested that the removal from buoyant suspensions happens at higher rates. The enhancement of removal is likely due to gravitational instabilities, such as fingering, at two-fluid interface. Previous studies have all sought to suppress flocculation, and no simple model exists to predict the removal rates under the effect of such instabilities. This study examines whether or not flocculation hampers instability formation and presents a simple removal rate model accounting for gravitational instabilities. A buoyant suspension of flocculated Kaolinite overlying a base of clear saltwater was investigated in a laboratory tank. Concentration was continuously measured in both layers with a pair of OBS sensors, and interface was monitored with digital cameras. Snapshots from the video were used to measure finger velocity. Samples of flocculated particles at the interface were extracted to retrieve floc size data using a floc camera. Flocculation did not stop creation of settling-driven fingers. A simple cylinder-based force balance model was capable of predicting finger velocity. Analogy of fingering process of fine grained suspensions to thermal plume formation and the concept of Grashof number enabled us to model finger spacing as a function of initial concentration. Finally, from geometry, the effective cross-sectional area was correlated to finger spacing. Reformulating the outward flux expression was done by substitution of finger velocity, rather than particle settling velocity, and finger area instead of total area. A box model along with the proposed outward flux was used to predict the SSC in buoyant layer. The model quantifies removal flux based on the initial SSC and is in good agreement with the experimental data.

  14. Fingerprint recognition with identical twin fingerprints.

    PubMed

    Tao, Xunqiang; Chen, Xinjian; Yang, Xin; Tian, Jie

    2012-01-01

    Fingerprint recognition with identical twins is a challenging task due to the closest genetics-based relationship existing in the identical twins. Several pioneers have analyzed the similarity between twins' fingerprints. In this work we continue to investigate the topic of the similarity of identical twin fingerprints. Our study was tested based on a large identical twin fingerprint database that contains 83 twin pairs, 4 fingers per individual and six impressions per finger: 3984 (83*2*4*6) images. Compared to the previous work, our contributions are summarized as follows: (1) Two state-of-the-art fingerprint identification methods: P071 and VeriFinger 6.1 were used, rather than one fingerprint identification method in previous studies. (2) Six impressions per finger were captured, rather than just one impression, which makes the genuine distribution of matching scores more realistic. (3) A larger sample (83 pairs) was collected. (4) A novel statistical analysis, which aims at showing the probability distribution of the fingerprint types for the corresponding fingers of identical twins which have same fingerprint type, has been conducted. (5) A novel analysis, which aims at showing which finger from identical twins has higher probability of having same fingerprint type, has been conducted. Our results showed that: (a) A state-of-the-art automatic fingerprint verification system can distinguish identical twins without drastic degradation in performance. (b) The chance that the fingerprints have the same type from identical twins is 0.7440, comparing to 0.3215 from non-identical twins. (c) For the corresponding fingers of identical twins which have same fingerprint type, the probability distribution of five major fingerprint types is similar to the probability distribution for all the fingers' fingerprint type. (d) For each of four fingers of identical twins, the probability of having same fingerprint type is similar.

  15. A New Method to Assess Asymmetry in Fingerprints Could Be Used as an Early Indicator of Type 2 Diabetes Mellitus

    PubMed Central

    Morris, Molly R.; Ludwar, Bjoern Ch.; Swingle, Evan; Mamo, Mahelet N.; Shubrook, Jay H.

    2016-01-01

    Background: Inexpensive screening tools are needed to identify individuals predisposed to developing diabetes mellitus (DM). Such early identification coupled with an effective intervention could help many people avoid the substantial health costs of this disease. We investigated the hypothesis that fluctuating asymmetry (FA) in fingerprints is an indicator of type 2 diabetes mellitus (T2DM). Methods: Participants with T2DM, with T1DM, and without any indication or known family history of diabetes were fingerprinted with a Crossmatch Verifier 320 LC scanner. Asymmetry scores for each finger pair were assessed using both pattern analysis (ridge counts), and a wavelet-based analysis. Results: Both methods for scoring asymmetry predicted risk of T2DM for finger pair IV, controlling for gender and age. AUC scores were significantly greater than the null for pattern asymmetry scores (finger IV AUC = 0.74), and wavelet asymmetry scores for finger pair IV (AUC = 0.73) and finger pair V (AUC = 0.73), for predicting T2DM. In addition, wavelet asymmetry scores for finger pair IV (AUC = 0.80) and finger pair V (AUC = 0.85) significantly predicted risk of T1DM. Conclusions: A diagnostic tool based on FA in the fingerprints of finger pair IV, measured using a wavelet analysis could be developed for predicting risk prior to associated health problems for both T2DM and T1DM. In addition, given that that the prints for fingers IV and V develop during the 14-17 weeks of gestation, we predict that interventions during this time period of pregnancy will be most successful. PMID:26830490

  16. A Cross-Sectional Study on the Palmar Dermatoglyphics in Relation to Carcinoma Breast Patients

    PubMed Central

    Raizada, Aprajita; Johri, Vishwawas; Ramnath, T; Chowdhary, DS; Garg, RP

    2013-01-01

    Introduction: Dermatoglyphics is a collective term for all the integumentary features (skin patterning of the fingers, toes, palms and soles) and it applies to the division of the anatomy which embraces their study. Aims and Objectives: The purpose of this study was to examine the predominant finger tip patterns in the patients of carcinoma breast. An attempt is also being made to devise a score to assess the risk variables. Materials and Methods: The fingerprints of 100 carcinoma breast patients were obtained and they were compared with those of 100 females who were not suffering from any malignancy till date. The different quantitative parameters of each hand of both the cancer patients and the controls were studied. The parameters which were included were the fingertip ridge pattern, the ridge count in the individual fingers, the Total Finger Ridge Count (TFRC) and the Absolute Finger Ridge Count (AFRC). Results: There was a significant increase in the arch pattern and a decrease in the radial loops in the right thumb (p<0.001), the left thumb (p<0.001), the left index finger (p<0.001) and the left middle finger (p<0.001). A comparison of all the five fingers of both the left and right hands of the cancer patients with the controls showed an arch pattern (p<0.001) with the highest frequency. The lower values of the TFRC (below 50) were associated with carcinoma breast .The lower values of the AFRC (below 100) were associated with the cancer patients. Conclusion: This study was able to establish a specific finger tip predominance in the Carcinoma breast patients. PMID:23730629

  17. A New Method to Assess Asymmetry in Fingerprints Could Be Used as an Early Indicator of Type 2 Diabetes Mellitus.

    PubMed

    Morris, Molly R; Ludwar, Bjoern Ch; Swingle, Evan; Mamo, Mahelet N; Shubrook, Jay H

    2016-07-01

    Inexpensive screening tools are needed to identify individuals predisposed to developing diabetes mellitus (DM). Such early identification coupled with an effective intervention could help many people avoid the substantial health costs of this disease. We investigated the hypothesis that fluctuating asymmetry (FA) in fingerprints is an indicator of type 2 diabetes mellitus (T2DM). Participants with T2DM, with T1DM, and without any indication or known family history of diabetes were fingerprinted with a Crossmatch Verifier 320 LC scanner. Asymmetry scores for each finger pair were assessed using both pattern analysis (ridge counts), and a wavelet-based analysis. Both methods for scoring asymmetry predicted risk of T2DM for finger pair IV, controlling for gender and age. AUC scores were significantly greater than the null for pattern asymmetry scores (finger IV AUC = 0.74), and wavelet asymmetry scores for finger pair IV (AUC = 0.73) and finger pair V (AUC = 0.73), for predicting T2DM. In addition, wavelet asymmetry scores for finger pair IV (AUC = 0.80) and finger pair V (AUC = 0.85) significantly predicted risk of T1DM. A diagnostic tool based on FA in the fingerprints of finger pair IV, measured using a wavelet analysis could be developed for predicting risk prior to associated health problems for both T2DM and T1DM. In addition, given that that the prints for fingers IV and V develop during the 14-17 weeks of gestation, we predict that interventions during this time period of pregnancy will be most successful. © 2016 Diabetes Technology Society.

  18. Reorganization of finger coordination patterns through motor exploration in individuals after stroke.

    PubMed

    Ranganathan, Rajiv

    2017-09-11

    Impairment of hand and finger function after stroke is common and affects the ability to perform activities of daily living. Even though many of these coordination deficits such as finger individuation have been well characterized, it is critical to understand how stroke survivors learn to explore and reorganize their finger coordination patterns for optimizing rehabilitation. In this study, I examine the use of a body-machine interface to assess how participants explore their movement repertoire, and how this changes with continued practice. Ten participants with chronic stroke wore a data glove and the finger joint angles were mapped on to the position of a cursor on a screen. The task of the participants was to move the cursor back and forth between two specified targets on a screen. Critically, the map between the finger movements and cursor motion was altered so that participants sometimes had to generate coordination patterns that required finger individuation. There were two phases to the experiment - an initial assessment phase on day 1, followed by a learning phase (days 2-5) where participants trained to reorganize their coordination patterns. Participants showed difficulty in performing tasks which had maps that required finger individuation, and the degree to which they explored their movement repertoire was directly related to clinical tests of hand function. However, over four sessions of practice, participants were able to learn to reorganize their finger movement coordination pattern and improve their performance. Moreover, training also resulted in improvements in movement repertoire outside of the context of the specific task during free exploration. Stroke survivors show deficits in movement repertoire in their paretic hand, but facilitating movement exploration during training can increase the movement repertoire. This suggests that exploration may be an important element of rehabilitation to regain optimal function.

  19. Coarsening in the buoyancy-driven instability of a reaction-diffusion front.

    PubMed

    Böckmann, Martin; Müller, Stefan C

    2004-10-01

    When propagating in a vertical direction an autocatalytic reaction front associated with a change in density can become buoyantly unstable, leading to the formation of a fingerlike pattern. Later on these fingers start to interact. Their temporal evolution is studied experimentally by tracking the horizontal and vertical locations of the extrema of the front pattern. A proceeding development towards larger spatial scales is found. This is reflected in the differences in the vertical speed of neighboring fingers: continually some fingers start to decelerate and vanish finally in the neighboring ones which show a simultaneous acceleration. In addition, weak lateral movements of fingers towards gaps are observed, but there is no evidence for a correlation with the extinction of fingers.

  20. Osmosis-driven viscous fingering of oil-in-water emulsions

    NASA Astrophysics Data System (ADS)

    Liu, Ying; Rallabandi, Bhargav; Baskaran, Mrudhula; Stone, Howard

    2017-11-01

    Viscous fingering occurs when a low viscosity fluid invades a more viscous fluid. Fingering of two miscible fluids is more complicated than that of immiscible fluids in that there is no sharp fluid-fluid interface and diffusion occurs between the phases. We experimentally studied the fingering of two miscible fluids: an oil-in-water emulsion and a sodium chloride solution. When the concentration of sodium chloride in the water phase in the emulsion exceeds that in the sodium chloride solution, the consequent osmotic flow automatically facilitates the occurrence of the fingering. On the contrary, when the sodium chloride solution has higher concentration, the spreading of emulsion is more uniform than the case without the concentration difference. We provide a model to rationalize and quantify these observations.

  1. Adhesive strips: a simple and inexpensive trick for finger holding in hand surgery.

    PubMed

    Brutus, J P; Nikolis, A; Ortiz, S; Cordoba, C

    2002-12-01

    Many finger holding devices have been developed to retract digits and provide exposure during hand surgery. We describe a simple, and cheap trick to keep fingers out of the way using adhesive strips that has proven efficient and helpful.

  2. Haptic identification of objects and their depictions.

    PubMed

    Klatzky, R L; Loomis, J M; Lederman, S J; Wake, H; Fujita, N

    1993-08-01

    Haptic identification of real objects is superior to that of raised two-dimensional (2-D) depictions. Three explanations of real-object superiority were investigated: contribution of material information, contribution of 3-D shape and size, and greater potential for integration across the fingers. In Experiment 1, subjects, while wearing gloves that gently attenuated material information, haptically identified real objects that provided reduced cues to compliance, mass, and part motion. The gloves permitted exploration with free hand movement, a single outstretched finger, or five outstretched fingers. Performance decreased over these three conditions but was superior to identification of pictures of the same objects in all cases, indicating the contribution of 3-D structure and integration across the fingers. Picture performance was also better with five fingers than with one. In Experiment 2, the subjects wore open-fingered gloves, which provided them with material information. Consequently, the effect of type of exploration was substantially reduced but not eliminated. Material compensates somewhat for limited access to object structure but is not the primary basis for haptic object identification.

  3. A finger exoskeleton for rehabilitation and brain image study.

    PubMed

    Tang, Zhenjin; Sugano, Shigeki; Iwata, Hiroyasu

    2013-06-01

    This paper introduces the design, fabrication and evaluation of the second generation prototype of a magnetic resonance compatible finger rehabilitation robot. It can not only be used as a finger rehabilitation training tool after a stroke, but also to study the brain's recovery process during the rehabilitation therapy (ReT). The mechanical design of the current generation has overcome the disadvantage in the previous version[13], which can't provide precise finger trajectories during flexion and extension motion varying with different finger joints' torques. In addition, in order to study the brain activation under different training strategies, three control modes have been developed, compared to only one control mode in the last prototype. The current prototype, like the last version, uses an ultrasonic motor as its actuator to enable the patient to do extension and flexion rehabilitation exercises in two degrees of freedom (DOF) for each finger. Finally, experiments have been carried out to evaluate the performances of this device.

  4. Two- and Three-Dimensional Numerical Experiments Representing Two Limiting Cases of an In-Line Pair of Finger Seal Components

    NASA Technical Reports Server (NTRS)

    Braun, M. J.; Steinetz, B. M.; Kudriavtsev, V. V.; Proctor, M. P.; Kiraly, L. James (Technical Monitor)

    2002-01-01

    The work presented here concerns the numerical development and simulation of the flow, pressure patterns and motion of a pair of fingers arranged behind each other and axially aligned in-line. The fingers represent the basic elemental component of a Finger Seal (FS) and form a tight seal around the rotor. Yet their flexibility allows compliance with rotor motion and in a passive-adaptive mode complies also with the hydrodynamic forces induced by the flowing fluid. While the paper does not treat the actual staggered configuration of a finger seal, the inline arrangement represents a first step towards that final goal. The numerical 2-D (axial-radial) and 3-D results presented herein were obtained using a commercial package (CFD-ACE+). Both models use an integrated numerical approach, which couples the hydrodynamic fluid model (Navier-Stokes based) to the solid mechanics code that models the compliance of the fingers.

  5. Insights using the molecular model of Lipoxygenase from Finger millet (Eleusine coracana (L.)).

    PubMed

    Tiwari, Apoorv; Avashthi, Himanshu; Jha, Richa; Srivastava, Ambuj; Kumar Garg, Vijay; Wasudev Ramteke, Pramod; Kumar, Anil

    2016-01-01

    Lipoxygenase-1 (LOX-1) protein provides defense against pests and pathogens and its presence have been positively correlated with plant resistance against pathogens. Linoleate is a known substrate of lipoxygenase and it induces necrosis leading to the accumulation of isoflavonoid phytoalexins in plant leaves. Therefore, it is of interest to study the structural features of LOX-1 from Finger millet. However, the structure ofLOX-1 from Finger millet is not yet known. A homology model of LOX-1 from Finger millet is described. Domain architecture study suggested the presence of two domains namely PLAT (Phospho Lipid Acyl Transferase) and lipoxygenase. Molecular docking models of linoleate with lipoxygenase from finger millet, rice and sorghum are reported. The features of docked models showed that finger millet have higher pathogen resistance in comparison to other cereal crops. This data is useful for the molecular cloning of fulllength LOX-1 gene for validating its role in improving plant defense against pathogen infection and for various other biological processes.

  6. On the granular fingering instability: controlled triggering in laboratory experiments and numerical simulations

    NASA Astrophysics Data System (ADS)

    Vriend, Nathalie; Tsang, Jonny; Arran, Matthew; Jin, Binbin; Johnsen, Alexander

    2017-11-01

    When a mixture of small, smooth particles and larger, coarse particles is released on a rough inclined plane, the initial uniform front may break up in distinct fingers which elongate over time. This fingering instability is sensitive to the unique arrangement of individual particles and is driven by granular segregation (Pouliquen et al., 1997). Variability in initial conditions create significant limitations for consistent experimental and numerical validation of newly developed theoretical models (Baker et al., 2016) for finger formation. We present an experimental study using a novel tool that sets the initial fingering width of the instability. By changing this trigger width between experiments, we explore the response of the avalanche breakup to perturbations of different widths. Discrete particle simulations (using MercuryDPM, Thornton et al., 2012) are conducted under a similar setting, reproducing the variable finger width, allowing validation between experiments and numerical simulations. A good agreement between simulations and experiments is obtained, and ongoing theoretical work is briefly introduced. NMV acknowledges the Royal Society Dorothy Hodgkin Research Fellowship.

  7. Dermatoglyphic analysis of La Liébana (Cantabria, Spain). 2. Finger ridge counts.

    PubMed

    Martín, J; Gómez, P

    1993-06-01

    The results of univariate and multivariate analyses of the quantitative finger dermatoglyphic traits (i.e. ridge counts) of a sample of 109 males and 88 females from La Liébana (Cantabria, Spain) are reported. Univariate results follow the trends usually found in previous studies, e.g., ranking of finger ridge counts, bilateral asymmetry or shape of the distributions of the frequencies. However, sexual dimorphism is nearly inexistent concerning finger ridge counts. This lack of dimorphism could be related to certain characteristics of the distribution of finger dermatoglyphic patterns previously reported by the same authors. The multivariate description has been carried out by means of principal component analysis (with varimax rotation to obtain the final solution) of the correlation matrices computed from the 10 maximal finger ridge counts. Although the results do not necessarily prove the concept of developmental fields ("field theory" and later modifications), some precepts of the theory are present: field polarization and field overlapping.

  8. Experimental viscous fingering in a tapered radial Hele-Shaw cell

    NASA Astrophysics Data System (ADS)

    Bongrand, Gregoire; Tsai, Peichun Amy; Complex Fludis Group Team

    2017-11-01

    The fluid-fluid displacement in porous media is a common process that finds direct applications in various fields, such as enhanced oil recovery and geological CO2 sequestration. In this work, we experimentally investigate the influence of converging cells on viscous fingering instabilities using a radially-tapered cell. For air displacing oil, in contrast to the classical Saffman-Taylor fingering, our results show that a converging gradient in a radial propagation can provide a stabilizing effect and hinder fingering. For a fixed gap gradient and thickness, with increasing injection rates we find a stable displacement under small flow rates, whereas unstable fingering occurs above a certain threshold. We further investigate this critical flow rate delineating the stable and unstable regimes for different gap gradients. These results reveal that the displacement efficiency not only depends on the fluid properties but also on the interfacial velocity and channel structure. The latter factors provide a useful and convenient control to either trigger or inhibit fingering instability. NSERC Discovery, Accelerator, and CRC programs.

  9. Robust Operation of Tendon-Driven Robot Fingers Using Force and Position-Based Control Laws

    NASA Technical Reports Server (NTRS)

    Hargrave, Brian (Inventor); Abdallah, Muhammad E (Inventor); Reiland, Matthew J (Inventor); Diftler, Myron A (Inventor); Strawser, Philip A (Inventor); Platt, Jr., Robert J. (Inventor); Ihrke, Chris A. (Inventor)

    2013-01-01

    A robotic system includes a tendon-driven finger and a control system. The system controls the finger via a force-based control law when a tension sensor is available, and via a position-based control law when a sensor is not available. Multiple tendons may each have a corresponding sensor. The system selectively injects a compliance value into the position-based control law when only some sensors are available. A control system includes a host machine and a non-transitory computer-readable medium having a control process, which is executed by the host machine to control the finger via the force- or position-based control law. A method for controlling the finger includes determining the availability of a tension sensor(s), and selectively controlling the finger, using the control system, via the force or position-based control law. The position control law allows the control system to resist disturbances while nominally maintaining the initial state of internal tendon tensions.

  10. Placement of temperature probe in bovine vagina for continuous measurement of core-body temperature.

    PubMed

    Lee, C N; Gebremedhin, K G; Parkhurst, A; Hillman, P E

    2015-09-01

    There has been increasing interest to measure core-body temperature in cattle using internal probes. This study examined the placement of HOBO water temperature probe with an anchor, referred to as the "sensor pack" (Hillman et al. Appl Eng Agric ASAE 25(2):291-296, 2009) in the vagina of multiparous Holstein cows under grazing conditions. Two types of anchors were used: (a) long "fingers" (4.5-6 cm), and (b) short "fingers" (3.5 cm). The long-finger anchors stayed in one position while the short-finger anchors were not stable in one position (rotate) within the vagina canal and in some cases came out. Vaginal temperatures were recorded every minute and the data collected were then analyzed using exponential mixed model regression for non-linear data. The results showed that the core-body temperatures for the short-finger anchors were lower than the long-finger anchors. This implied that the placement of the temperature sensor within the vagina cavity may affect the data collected.

  11. Placement of temperature probe in bovine vagina for continuous measurement of core-body temperature

    NASA Astrophysics Data System (ADS)

    Lee, C. N.; Gebremedhin, K. G.; Parkhurst, A.; Hillman, P. E.

    2015-09-01

    There has been increasing interest to measure core-body temperature in cattle using internal probes. This study examined the placement of HOBO water temperature probe with an anchor, referred to as the "sensor pack" (Hillman et al. Appl Eng Agric ASAE 25(2):291-296, 2009) in the vagina of multiparous Holstein cows under grazing conditions. Two types of anchors were used: (a) long "fingers" (4.5-6 cm), and (b) short "fingers" (3.5 cm). The long-finger anchors stayed in one position while the short-finger anchors were not stable in one position (rotate) within the vagina canal and in some cases came out. Vaginal temperatures were recorded every minute and the data collected were then analyzed using exponential mixed model regression for non-linear data. The results showed that the core-body temperatures for the short-finger anchors were lower than the long-finger anchors. This implied that the placement of the temperature sensor within the vagina cavity may affect the data collected.

  12. Development of neural network techniques for finger-vein pattern classification

    NASA Astrophysics Data System (ADS)

    Wu, Jian-Da; Liu, Chiung-Tsiung; Tsai, Yi-Jang; Liu, Jun-Ching; Chang, Ya-Wen

    2010-02-01

    A personal identification system using finger-vein patterns and neural network techniques is proposed in the present study. In the proposed system, the finger-vein patterns are captured by a device that can transmit near infrared through the finger and record the patterns for signal analysis and classification. The biometric system for verification consists of a combination of feature extraction using principal component analysis and pattern classification using both back-propagation network and adaptive neuro-fuzzy inference systems. Finger-vein features are first extracted by principal component analysis method to reduce the computational burden and removes noise residing in the discarded dimensions. The features are then used in pattern classification and identification. To verify the effect of the proposed adaptive neuro-fuzzy inference system in the pattern classification, the back-propagation network is compared with the proposed system. The experimental results indicated the proposed system using adaptive neuro-fuzzy inference system demonstrated a better performance than the back-propagation network for personal identification using the finger-vein patterns.

  13. The discovery of zinc fingers and their development for practical applications in gene regulation and genome manipulation.

    PubMed

    Klug, Aaron

    2010-02-01

    A long-standing goal of molecular biologists has been to construct DNA-binding proteins for the control of gene expression. The classical Cys2His2 (C2H2) zinc finger design is ideally suited for such purposes. Discriminating between closely related DNA sequences both in vitro and in vivo, this naturally occurring design was adopted for engineering zinc finger proteins (ZFPs) to target genes specifically. Zinc fingers were discovered in 1985, arising from the interpretation of our biochemical studies on the interaction of the Xenopus protein transcription factor IIIA (TFIIIA) with 5S RNA. Subsequent structural studies revealed its three-dimensional structure and its interaction with DNA. Each finger constitutes a self-contained domain stabilized by a zinc (Zn) ion ligated to a pair of cysteines and a pair of histidines and also by an inner structural hydrophobic core. This discovery showed not only a new protein fold but also a novel principle of DNA recognition. Whereas other DNA-binding proteins generally make use of the 2-fold symmetry of the double helix, functioning as homo- or heterodimers, zinc fingers can be linked linearly in tandem to recognize nucleic acid sequences of varying lengths. This modular design offers a large number of combinatorial possibilities for the specific recognition of DNA (or RNA). It is therefore not surprising that the zinc finger is found widespread in nature, including 3% of the genes of the human genome. The zinc finger design can be used to construct DNA-binding proteins for specific intervention in gene expression. By fusing selected zinc finger peptides to repression or activation domains, genes can be selectively switched off or on by targeting the peptide to the desired gene target. It was also suggested that by combining an appropriate zinc finger peptide with other effector or functional domains, e.g. from nucleases or integrases to form chimaeric proteins, genomes could be modified or manipulated. The first example of the power of the method was published in 1994 when a three-finger protein was constructed to block the expression of a human oncogene transformed into a mouse cell line. The same paper also described how a reporter gene was activated by targeting an inserted 9-base pair (bp) sequence, which acts as the promoter. Thus, by fusing zinc finger peptides to repression or activation domains, genes can be selectively switched off or on. It was also suggested that, by combining zinc fingers with other effector or functional domains, e.g. from nucleases or integrases, to form chimaeric proteins, genomes could be manipulated or modified. Several applications of such engineered ZFPs are described here, including some of therapeutic importance, and also their adaptation for breeding improved crop plants.

  14. A Novel Approach for Reconstruction of Finger Neurocutaneous Defect: A Sensory Reverse Dorsal Digital Artery Flap from the Neighboring Digit.

    PubMed

    Feng, Shi-Ming; Sun, Qing-Qing; Cheng, Jian; Wang, Ai-Guo

    2017-11-01

    Providing soft tissue coverage for finger neurocutaneous defects presents aesthetic and sensory challenges. A common source for reconstruction of soft tissue defects of the fingers is the same finger. However, when the donor areas are damaged by concomitant injuries, this option is not available. The present study aims to reconstruct finger neurocutaneous defects using a sensory reverse dorsal digital artery flap from the neighboring digit and to evaluate the efficacy of this technique. The study included 16 patients, with an average age of 34.9 years (range, 20-53 years) at the time of surgery, from May 2010 to June 2013. The sensory reverse dorsal digital artery flap was used in all 16 patients, who had a combination of soft tissue and digital nerve defects. The mean size of the soft tissue defects was 3.1 cm × 2.0 cm, and the mean flap size was 3.3 cm × 2.2 cm. The length of the nerve defects ranged from 1.3 to 2.5 cm (mean, 2.0 cm), which were reconstructed with dorsal branches of the proper digital nerve transfer. The active motion of the fingers (injured and donor) and the flap sensibility (static two-point discrimination) were measured. The appearance and functional recovery of the injured finger and the donor site were assessed using the Michigan Hand Outcomes Questionnaire. All flaps survived completely. No complications were reported, and no further flap debulking procedure was required. At the mean follow-up period of 24 months (range, 18-30 months), the mean static two-point discrimination was 6.5 mm (range, 5-10 mm) of the reconstructed area; the mean ranges of motions of the injured finger and the opposite finger at the proximal interphalangeal and distal interphalangeal joints were 102.2° and 103.5°, and 70.3° and 76.5°, respectively. The average ranges of motions of the metacarpophalangeal and proximal interphalangeal joints of the donor fingers were 90° and 103.4°, respectively. Based on the Michigan Hand Outcomes Questionnaire, 10 patients were strongly satisfied and 6 were satisfied with the functional recovery of the injured finger; however, 13 patients were strongly satisfied and 3 were satisfied with the appearance of the injured finger. The sensory reverse dorsal digital artery flap from the neighboring digit, based on the dorsal branch of the digital artery, is an effective and additional option for finger neurocutaneous defect reconstruction when use of the local and regional flaps is not feasible. © 2017 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

  15. Lateral movements in Rayleigh-Taylor instabilities due to frontiers. Numerical analysis

    NASA Astrophysics Data System (ADS)

    Fernandez, D.; Binda, L.; Zalts, A.; El Hasi, C.; D'Onofrio, A.

    2018-01-01

    Numerical simulations were performed for Rayleigh-Taylor (RT) hydrodynamic instabilities when a frontier is present. The frontier formed by the interface between two fluids prevents the free movement of the fingers created by the instability. As a consequence, transversal movements at the rear of the fingers are observed in this area. These movements produce collapse of the fingers (two or more fingers join in one finger) or oscillations in the case that there is no collapse. The transversal velocity of the fingers, the amplitude of the oscillations, and the wave number of the RT instabilities as a function of the Rayleigh number (Ra) were studied near the frontier. We verified numerically that in classical RT instabilities, without a frontier, these lateral movements do not occur; only with a physical frontier, the transversal displacements of the fingers appear. The transverse displacement velocity and the initial wave number increase with Ra. This leads to the collapse of the fingers, diminishing the wave number of the instabilities at the interface. Instead, no significant changes in the amplitude of the oscillations are observed modifying Ra. The numerical results are independent of the type or origin of the frontier (gas-liquid, liquid-liquid, or solid-liquid). The numerical results are in good agreement with the experimental results reported by Binda et al. [Chaos 28, 013107 (2018)]. Based on these results, it was possible to determine the cause of the transverse displacements, which had not been explained until now.

  16. EEG correlates of finger movements with different inertial load conditions as revealed by averaging techniques.

    PubMed

    Slobounov, S; Tutwiler, R; Rearick, M; Challis, J H

    1999-10-01

    The present study was aimed to further address the general empirical question regarding the sensitivity of EEG correlates toward specific kinematic and/or kinetic movement parameters. In particular, we examined whether adding different inertial loads to the index finger, while a subject produced various amplitudes of discrete finger movements, influenced the movement-related potentials (MRP). Our experimental design systematically controlled the angular displacement, velocity and acceleration (kinematic) profiles of finger movement while torque (kinetics) was varied by adding different external loads opposing finger flexion movement. We applied time-domain averaging of EEG single trials in order to extract three movement-related potentials (BP-600 to -500 BP-100 to 0 and N0 to 100) preceding and accompanying 25, 50 and 75 degrees unilateral finger movements with no inertial load, small (100 g) and large (200 g) loading. It was shown that both inertial load and the degree of angular displacement of index finger flexion increased the amplitude of late components of MRP (BP-100 to 0 and N0 to 100) over frontal and precentral areas. In contrast, the external load and movement amplitude manipulations did not influence the earlier component of the MRP (BP- 600 to -500). Overall, the data demonstrate that adding inertial load to the finger with larger angular displacements involves systematic increase in activation across frontal and precentral areas that are related to movement initiation as reflected in BP-100 to 0 and N0 to 100.

  17. Neuromagnetic Cerebellar Activity Entrains to the Kinematics of Executed Finger Movements.

    PubMed

    Marty, Brice; Wens, V; Bourguignon, M; Naeije, G; Goldman, S; Jousmäki, V; De Tiège, X

    2018-05-03

    This magnetoencephalography (MEG) study aims at characterizing the coupling between cerebellar activity and the kinematics of repetitive self-paced finger movements. Neuromagnetic signals were recorded in 11 right-handed healthy adults while they performed repetitive flexion-extensions of right-hand fingers at three different movement rates: slow (~ 1 Hz), medium (~ 2 Hz), and fast (~ 3 Hz). Right index finger acceleration was monitored with an accelerometer. Coherence analysis was used to index the coupling between right index finger acceleration and neuromagnetic signals. Dynamic imaging of coherent sources was used to locate coherent sources. Coupling directionality between primary sensorimotor (SM1), cerebellar, and accelerometer signals was assessed with renormalized partial directed coherence. Permutation-based statistics coupled with maximum statistic over the entire brain volume or restricted to the cerebellum were used. At all movement rates, maximum coherence peaked at SM1 cortex contralateral to finger movements at movement frequency (F0) and its first harmonic (F1). Significant (statistics restricted to the cerebellum) coherence consistently peaked at the right posterior lobe of the cerebellum at F0 with no influence of movement rate. Coupling between Acc and cerebellar signals was significantly stronger in the afferent than in the efferent direction with no effective contribution of cortico-cerebellar or cerebello-cortical pathways. This study demonstrates the existence of significant coupling between finger movement kinematics and neuromagnetic activity at the posterior cerebellar lobe ipsilateral to finger movement at F0. This coupling is mainly driven by spinocerebellar, presumably proprioceptive, afferences.

  18. Simulation of light transport in arthritic- and non-arthritic human fingers

    NASA Astrophysics Data System (ADS)

    Milanic, Matija; Paluchowski, Lukasz A.; Randeberg, Lise L.

    2014-03-01

    Rheumatoid arthritis is a disease that frequently leads to joint destruction. It has high incidence rates worldwide, and the disease significantly reduces patient's quality of life due to pain, swelling and stiffness of the affected joints. Early diagnosis is necessary to improve course of the disease, therefore sensitive and accurate diagnostic tools are required. Optical imaging techniques have capability for early diagnosis and monitoring of arthritis. As compared to conventional diagnostic techniques optical technique is a noninvasive, noncontact and fast way of collecting diagnostic information. However, a realistic model of light transport in human joints is needed for understanding and developing of such optical diagnostic tools. The aim of this study is to develop a 3D numerical model of light transport in a human finger. The model will guide development of a hyperspectral imaging (HSI) diagnostic modality for arthritis in human fingers. The implemented human finger geometry is based on anatomical data. Optical data of finger tissues are adjusted to represent either an arthritic or an unaffected finger. The geometry and optical data serve as input into a 3D Monte Carlo method, which calculate diffuse reflectance, transmittance and absorbed energy distributions. The parameters of the model are optimized based on HIS-measurements of human fingers. The presented model serves as an important tool for understanding and development of HSI as an arthritis diagnostic modality. Yet, it can be applied to other optical techniques and finger diseases.

  19. 21 CFR 890.5410 - Powered finger exerciser.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Powered finger exerciser. 890.5410 Section 890.5410 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5410 Powered finger...

  20. 21 CFR 890.5410 - Powered finger exerciser.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Powered finger exerciser. 890.5410 Section 890.5410 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5410 Powered finger...

  1. 21 CFR 890.5410 - Powered finger exerciser.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Powered finger exerciser. 890.5410 Section 890.5410 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5410 Powered finger...

  2. 21 CFR 890.5410 - Powered finger exerciser.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Powered finger exerciser. 890.5410 Section 890.5410 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5410 Powered finger...

  3. 21 CFR 890.5410 - Powered finger exerciser.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Powered finger exerciser. 890.5410 Section 890.5410 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5410 Powered finger...

  4. Fingered bola body, bola with same, and methods of use

    NASA Technical Reports Server (NTRS)

    Dzenitis, John M. (Inventor); Billica, Linda W. (Inventor)

    1994-01-01

    The present invention discloses bola bodies, bolas, and a snaring method which makes use such devices. A bola body, according to the present invention, is nonspherical or irregular in shape rather than a smooth sphere or ovoid body. One or more fingers extends from the bola body. These fingers may be relatively straight or they may have crooked or bent portions to enhance entanglement with a bola line or lines or with each other. Two or more of such fingers may be used and may be regularly or irregularly spaced apart on a bola body. A bola with such bodies includes lines which are connected to the other bodies. In one particular embodiment of a bola body, according to the present invention, the body has an irregular shape with a bottom rectangular portion and a top pyramid portion forming a nose. A plurality of fingers is extended from the pyramidal top portion with one finger extended up and away from each of four corners of the top portion. Such a bola body tends to be initially oriented with its nose and fingers against an object being snared since the body is pulled nose first when a bola line is secured at the tip of the pyramidal portion of the bola body. With such a bola, an unwrapping bola body can slip around a target member so that two of the rod-shaped fingers catch a bola line and guide it into an area or crook between the fingers and a side of the top pyramidal portion of the bola body. Tension on the bola line maintains the line in the crook and tends to press the fingers against the unwrapped target member to stabilize the wrapping of the line about the target member. With such a bola, it is difficult for two or more lines unwrapping in different directions to move past one another without being forced together by line tension. Also, the fingers of such bola bodies may hook and hold each other. The fingers may also hook or entangle some object on or portion of the target member. A probable known target member has known dimensions and shapes so that the bola may be sized and configured to reliably snare such a known target. The bolas can be optimally sized, fashioned, and configured to contact and hold a probable target of known size, dimension, and shape.

  5. [Microsurgery for severe flexion contracture of proximal interphalangeal joint].

    PubMed

    Fei, Xiaoxuan; Feng, Shiming; Gao, Shunhong

    2012-07-01

    To investigate the clinical results of cross-finger flap combined with laterodigital pedicled skin flap for repair of severe flexion contracture of the proximal interphalangeal joint. Between October 2008 and February 2011, 11 patients (11 fingers) with severe flexion contracture of the proximal interphalangeal joint were treated with cross-finger flap combined with laterodigital pedicled skin flap. There were 7 males and 4 females, aged 20-63 years (mean, 32.6 years). The causes of injury were crush or electric-saw injury in 7 cases, burn or explosive injury in 3 cases, and electrical injury in 1 case. The locations were the index finger in 4 cases, the middle finger in 2 cases, the ring finger in 2 cases, and the little finger in 3 cases. The mean disease duration was 12.4 months (range, 6-24 months). All cases were rated as type III according to Stern classification standard. The volar tissue defect ranged from 3.0 cm x 1.5 cm to 5.0 cm x 2.5 cm, with exposed tendons, nerves, vessels, or bone after scar relaxation. The defects were repaired with cross-finger flaps (2.2 cm x 1.8 cm to 3.8 cm x 2.5 cm) combined with laterodigital pedicled skin flaps (1.5 cm x 1.2 cm to 2.5 cm x 2.0 cm). Double laterodigital pedicled skin flaps were used in 3 cases. The flap donor site was sutured directly or repaired with the skin graft. All flaps survived completely and wound healed by first intention. The donor skin graft survived. All the patients were followed up 6-18 months (mean, 11.3 months). The finger appearance was satisfactory. The flaps had soft texture and good color in all cases. No obvious pigmentation or contraction was observed. The contracted fingers could extend completely with good active flexion and extension motion. At last follow-up, the extension of the proximal interphalangeal joint was 10-150. Based on proximal interphalangeal joint motion standard of Chinese Medical Association for hand surgery, the results were excellent in 6 cases, good in 4 cases, and fair in 1 case; the excellent and good rate was 90.9%. It is an easy and simple therapy t o cover wound area of severe flexion contracture of the proximal interphalangeal joint after scar relaxation using cross-finger flap combined with laterodigital pedicled skin flap, which can repair large defect and achieve good results in finger appearance and function.

  6. 16 CFR Figure 4 to Part 1610 - An Example of a Typical Indicator Finger

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false An Example of a Typical Indicator Finger 4 Figure 4 to Part 1610 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FLAMMABLE FABRICS ACT... Example of a Typical Indicator Finger ER25MR08.003 ...

  7. Population Structure and Diversity in Finger Millet (Eleusine coracana) Germplasm.

    USDA-ARS?s Scientific Manuscript database

    A genotypic analysis of 79 finger millet accessions (E. coracana subsp. coracana) from 11 African and 5 Asian countries, plus 14 wild E. coracana subsp. africana lines collected in Uganda and Kenya was conducted with 45 SSR markers distributed across the finger millet genome. Phylogenetic and popula...

  8. Haptic Distal Spatial Perception Mediated by Strings: Haptic "Looming"

    ERIC Educational Resources Information Center

    Cabe, Patrick A.

    2011-01-01

    Five experiments tested a haptic analog of optical looming, demonstrating string-mediated haptic distal spatial perception. Horizontally collinear hooks supported a weighted string held taut by a blindfolded participant's finger midway between the hooks. At the finger, the angle between string segments increased as the finger approached…

  9. Self-Expression or Teacher Influence: The Shaw System of Finger-Painting.

    ERIC Educational Resources Information Center

    Stankiewicz, Mary Ann

    1984-01-01

    Finger painting is often regarded as the epitome of free expression for children. However, a careful review of the history of Ruth Shaw's finger-painting system reveals that it was dominated by specific techniques and stylistic conventions taught without a critical understanding of art history or appreciation. (IS)

  10. 16 CFR Figure 4 to Part 1610 - An Example of a Typical Indicator Finger

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 2 2011-01-01 2011-01-01 false An Example of a Typical Indicator Finger 4 Figure 4 to Part 1610 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FLAMMABLE FABRICS ACT... Example of a Typical Indicator Finger ER25MR08.003 ...

  11. Flexible Piezoelectric Energy Harvesting from Mouse Click Motions

    PubMed Central

    Cha, Youngsu; Hong, Jin; Lee, Jaemin; Park, Jung-Min; Kim, Keehoon

    2016-01-01

    In this paper, we study energy harvesting from the mouse click motions of a robot finger and a human index finger using a piezoelectric material. The feasibility of energy harvesting from mouse click motions is experimentally and theoretically assessed. The fingers wear a glove with a pocket for including the piezoelectric material. We model the energy harvesting system through the inverse kinematic framework of parallel joints in a finger and the electromechanical coupling equations of the piezoelectric material. The model is validated through energy harvesting experiments in the robot and human fingers with the systematically varying load resistance. We find that energy harvesting is maximized at the matched load resistance to the impedance of the piezoelectric material, and the harvested energy level is tens of nJ. PMID:27399705

  12. Toward rules relating zinc finger protein sequences and DNA binding site preferences.

    PubMed

    Desjarlais, J R; Berg, J M

    1992-08-15

    Zinc finger proteins of the Cys2-His2 type consist of tandem arrays of domains, where each domain appears to contact three adjacent base pairs of DNA through three key residues. We have designed and prepared a series of variants of the central zinc finger within the DNA binding domain of Sp1 by using information from an analysis of a large data base of zinc finger protein sequences. Through systematic variations at two of the three contact positions (underlined), relatively specific recognition of sequences of the form 5'-GGGGN(G or T)GGG-3' has been achieved. These results provide the basis for rules that may develop into a code that will allow the design of zinc finger proteins with preselected DNA site specificity.

  13. Fuzzy based finger vein recognition with rotation invariant feature matching

    NASA Astrophysics Data System (ADS)

    Ezhilmaran, D.; Joseph, Rose Bindu

    2017-11-01

    Finger vein recognition is a promising biometric with commercial applications which is explored widely in the recent years. In this paper, a finger vein recognition system is proposed using rotation invariant feature descriptors for matching after enhancing the finger vein images with an interval type-2 fuzzy method. SIFT features are extracted and matched using a matching score based on Euclidian distance. Rotation invariance of the proposed method is verified in the experiment and the results are compared with SURF matching and minutiae matching. It is seen that rotation invariance is verified and the poor quality issues are solved efficiently with the designed system of finger vein recognition during the analysis. The experiments underlines the robustness and reliability of the interval type-2 fuzzy enhancement and SIFT feature matching.

  14. Prevalence of vibration-induced white finger in fluorspar mines in Weardale.

    PubMed Central

    Chatterjee, D S; Petrie, A; Taylor, W

    1978-01-01

    A combined epidemiological and clinical study of vibration-induced white finger (VWF) was carried out involving 115 men in four fluorspar mines. The overall prevalence of VWF was found to be 50% among 42 vibration-exposed subjects, while that of constitutional white finger (CWF) was 5-6% in all men studied. The VWF latent interval was 1-19 years with a mean of 5-6 years. An association was observed between the exposure time and VWF stages which included 18 men in Stage 0, three in the intermediate Stage of 0T/0N, five in Stage 2 and 16 in Stage 3; no men were seen at Stage 1. Among those with VWF in Stage 3, the index, middle and ring fingers were affected in both hands and the little fingers and thumbs were last to be involved. Clinically, on general examination, apart from vibration-induced white finger, the men in the 'vibration' group were not as healthy as those in the 'control' group. The circumference of the index fingers was not significantly different for the different groups. Neurological tests showed that the ridge test and, to a lesser extent, the two-point discrimination and the light touch tests, could be regarded as useful for the diagnosis of VWF. PMID:698134

  15. Temporal Control and Hand Movement Efficiency in Skilled Music Performance

    PubMed Central

    Goebl, Werner; Palmer, Caroline

    2013-01-01

    Skilled piano performance requires considerable movement control to accomplish the high levels of timing and force precision common among professional musicians, who acquire piano technique over decades of practice. Finger movement efficiency in particular is an important factor when pianists perform at very fast tempi. We document the finger movement kinematics of highly skilled pianists as they performed a five-finger melody at very fast tempi. A three-dimensional motion-capture system tracked the movements of finger joints, the hand, and the forearm of twelve pianists who performed on a digital piano at successively faster tempi (7–16 tones/s) until they decided to stop. Joint angle trajectories computed for all adjacent finger phalanges, the hand, and the forearm (wrist angle) indicated that the metacarpophalangeal joint contributed most to the vertical fingertip motion while the proximal and distal interphalangeal joints moved slightly opposite to the movement goal (finger extension). An efficiency measure of the combined finger joint angles corresponded to the temporal accuracy and precision of the pianists’ performances: Pianists with more efficient keystroke movements showed higher precision in timing and force measures. Keystroke efficiency and individual joint contributions remained stable across tempo conditions. Individual differences among pianists supported the view that keystroke efficiency is required for successful fast performance. PMID:23300946

  16. Finger-Vein Image Enhancement Using a Fuzzy-Based Fusion Method with Gabor and Retinex Filtering

    PubMed Central

    Shin, Kwang Yong; Park, Young Ho; Nguyen, Dat Tien; Park, Kang Ryoung

    2014-01-01

    Because of the advantages of finger-vein recognition systems such as live detection and usage as bio-cryptography systems, they can be used to authenticate individual people. However, images of finger-vein patterns are typically unclear because of light scattering by the skin, optical blurring, and motion blurring, which can degrade the performance of finger-vein recognition systems. In response to these issues, a new enhancement method for finger-vein images is proposed. Our method is novel compared with previous approaches in four respects. First, the local and global features of the vein lines of an input image are amplified using Gabor filters in four directions and Retinex filtering, respectively. Second, the means and standard deviations in the local windows of the images produced after Gabor and Retinex filtering are used as inputs for the fuzzy rule and fuzzy membership function, respectively. Third, the optimal weights required to combine the two Gabor and Retinex filtered images are determined using a defuzzification method. Fourth, the use of a fuzzy-based method means that image enhancement does not require additional training data to determine the optimal weights. Experimental results using two finger-vein databases showed that the proposed method enhanced the accuracy of finger-vein recognition compared with previous methods. PMID:24549251

  17. Integrating optical finger motion tracking with surface touch events.

    PubMed

    MacRitchie, Jennifer; McPherson, Andrew P

    2015-01-01

    This paper presents a method of integrating two contrasting sensor systems for studying human interaction with a mechanical system, using piano performance as the case study. Piano technique requires both precise small-scale motion of fingers on the key surfaces and planned large-scale movement of the hands and arms. Where studies of performance often focus on one of these scales in isolation, this paper investigates the relationship between them. Two sensor systems were installed on an acoustic grand piano: a monocular high-speed camera tracking the position of painted markers on the hands, and capacitive touch sensors attach to the key surfaces which measure the location of finger-key contacts. This paper highlights a method of fusing the data from these systems, including temporal and spatial alignment, segmentation into notes and automatic fingering annotation. Three case studies demonstrate the utility of the multi-sensor data: analysis of finger flexion or extension based on touch and camera marker location, timing analysis of finger-key contact preceding and following key presses, and characterization of individual finger movements in the transitions between successive key presses. Piano performance is the focus of this paper, but the sensor method could equally apply to other fine motor control scenarios, with applications to human-computer interaction.

  18. Integrating optical finger motion tracking with surface touch events

    PubMed Central

    MacRitchie, Jennifer; McPherson, Andrew P.

    2015-01-01

    This paper presents a method of integrating two contrasting sensor systems for studying human interaction with a mechanical system, using piano performance as the case study. Piano technique requires both precise small-scale motion of fingers on the key surfaces and planned large-scale movement of the hands and arms. Where studies of performance often focus on one of these scales in isolation, this paper investigates the relationship between them. Two sensor systems were installed on an acoustic grand piano: a monocular high-speed camera tracking the position of painted markers on the hands, and capacitive touch sensors attach to the key surfaces which measure the location of finger-key contacts. This paper highlights a method of fusing the data from these systems, including temporal and spatial alignment, segmentation into notes and automatic fingering annotation. Three case studies demonstrate the utility of the multi-sensor data: analysis of finger flexion or extension based on touch and camera marker location, timing analysis of finger-key contact preceding and following key presses, and characterization of individual finger movements in the transitions between successive key presses. Piano performance is the focus of this paper, but the sensor method could equally apply to other fine motor control scenarios, with applications to human-computer interaction. PMID:26082732

  19. Reduced servo-control of fatigued human finger extensor and flexor muscles.

    PubMed Central

    Hagbarth, K E; Bongiovanni, L G; Nordin, M

    1995-01-01

    1. In healthy human subjects holding the index finger semi-extended at the metacarpophalangeal joint against a moderate load, electromyographic (EMG) activity was recorded from the finger extensor and flexor muscles during different stages of muscle fatigue. The aim was to study the effect of muscle fatigue on the level of background EMG activity and on the reflex responses to torque pulses causing sudden extensor unloadings. Paired comparisons were made between the averaged EMG and finger deflection responses under two conditions: (1) at a stage of fatigue (following a sustained co-contraction) when great effort was required to maintain the finger position, and (2) under non-fatigue conditions while the subject tried to produce similar background EMG levels to those in the corresponding fatigue trials. 2. Both the unloading reflex in the extensor and the concurrent stretch reflex in the flexor were significantly less pronounced and had a longer latency in the fatigue trials. Consequently, the finger deflections had a larger amplitude and were arrested later in the fatigue trials. 3. It is concluded that--with avoidance of 'automatic gain compensation', i.e. reflex modifications attributable to differences in background EMG levels--the servo-like action of the unloading and stretch reflexes is reduced in fatigued finger extensor and flexor muscles. PMID:7562624

  20. Strength training improves the tri-digit finger-pinch force control of older adults.

    PubMed

    Keogh, Justin W; Morrison, Steve; Barrett, Rod

    2007-08-01

    To investigate the effect of unilateral upper-limb strength training on the finger-pinch force control of older men. Pretest and post-test 6-week intervention study. Exercise science research laboratory. Eleven neurologically fit older men (age range, 70-80y). The strength training group (n=7) trained twice a week for 6 weeks, performing dumbbell bicep curls, wrist flexions, and wrists extensions, while the control group subjects (n=4) maintained their normal activities. Changes in force variability, targeting error, peak power frequency, proportional power, sample entropy, digit force sharing, and coupling relations were assessed during a series of finger-pinch tasks. These tasks involved maintaining a constant or sinusoidal force output at 20% and 40% of each subject's maximum voluntary contraction. All participants performed the finger-pinch tasks with both the preferred and nonpreferred limbs. Analysis of covariance for between-group change scores indicated that the strength training group (trained limb) experienced significantly greater reductions in finger-pinch force variability and targeting error, as well as significantly greater increases in finger-pinch force, sample entropy, bicep curl, and wrist flexion strength than did the control group. A nonspecific upper-limb strength-training program may improve the finger-pinch force control of older men.

  1. Design of a Reconfigurable Robotic System for Flexoextension Fitted to Hand Fingers Size

    PubMed Central

    Castillo-Castaneda, Eduardo

    2016-01-01

    Due to the growing demand for assistance in rehabilitation therapies for hand movements, a robotic system is proposed to mobilize the hand fingers in flexion and extension exercises. The robotic system is composed by four, type slider-crank, mechanisms that have the ability to fit the user fingers length from the index to the little finger, through the adjustment of only one link for each mechanism. The trajectory developed by each mechanism corresponds to the natural flexoextension path of each finger. The amplitude of the rotations for metacarpophalangeal joint (MCP) and proximal interphalangeal joint (PIP) varies from 0 to 90° and the distal interphalangeal joint (DIP) varies from 0 to 60°; the joint rotations are coordinated naturally. The four R-RRT mechanisms orientation allows a 15° abduction movement for index, ring, and little fingers. The kinematic analysis of this mechanism was developed in order to assure that the displacement speed and smooth acceleration into the desired range of motion and the simulation results are presented. The reconfiguration of mechanisms covers about 95% of hand sizes of a group of Mexican adult population. Maximum trajectory tracking error is less than 3% in full range of movement and it can be compensated by the additional rotation of finger joints without injury to the user. PMID:27524880

  2. Relationship between the changes in blood flow and volume in the finger during a Braille character discrimination task.

    PubMed

    Murata, J; Murata, S; Soma, M; Nakae, H; Sato, Y; Kogo, H; Umeki, N

    2017-11-01

    We hypothesized that skin blood flow (SBF) of fingers are modulated during concentrated finger perception and that the changes in SBF reflect fluctuations in finger volume (FV). The aim of this study, therefore, was examine the relationship between the changes in SBF and FV during Braille reading. We measured SBF of the finger, cutaneous vascular conductance (CVC), FV, and arterial blood pressure during Braille reading performed under blind conditions in thirty healthy subjects. The subjects were instructed to read a flat plate with raised letters (Braille reading) for 15 seconds using their forefinger, and to touch a blank plate as a control for the Braille discrimination procedure. Arterial blood pressure slightly increased during Braille reading but remained unchanged during the touching of the blank plate. SBF, CVC, and FV were reduced during Braille reading (decreased by -26%, -29%, and -0.3 mL/100 mL respectively). Furthermore, a significant relationship was observed between the changes in SBF and FV (r=.613) during Braille reading. These results suggested that SBF of fingers is modulated during concentrated finger perception, and that the variability of blood flow reflects the response in FV. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Localized frustration and binding-induced conformational change in recognition of 5S RNA by TFIIIA zinc finger.

    PubMed

    Tan, Cheng; Li, Wenfei; Wang, Wei

    2013-12-19

    Protein TFIIIA is composed of nine tandemly arranged Cys2His2 zinc fingers. It can bind either to the 5S RNA gene as a transcription factor or to the 5S RNA transcript as a chaperone. Although structural and biochemical data provided valuable information on the recognition between the TFIIIIA and the 5S DNA/RNA, the involved conformational motions and energetic factors contributing to the binding affinity and specificity remain unclear. In this work, we conducted MD simulations and MM/GBSA calculations to investigate the binding-induced conformational changes in the recognition of the 5S RNA by the central three zinc fingers of TFIIIA and the energetic factors that influence the binding affinity and specificity at an atomistic level. Our results revealed drastic interdomain conformational changes between these three zinc fingers, involving the exposure/burial of several crucial DNA/RNA binding residues, which can be related to the competition between DNA and RNA for the binding of TFIIIA. We also showed that the specific recognition between finger 4/finger 6 and the 5S RNA introduces frustrations to the nonspecific interactions between finger 5 and the 5S RNA, which may be important to achieve optimal binding affinity and specificity.

  4. Finger-Shaped GelForce: Sensor for Measuring Surface Traction Fields for Robotic Hand.

    PubMed

    Sato, K; Kamiyama, K; Kawakami, N; Tachi, S

    2010-01-01

    It is believed that the use of haptic sensors to measure the magnitude, direction, and distribution of a force will enable a robotic hand to perform dexterous operations. Therefore, we develop a new type of finger-shaped haptic sensor using GelForce technology. GelForce is a vision-based sensor that can be used to measure the distribution of force vectors, or surface traction fields. The simple structure of the GelForce enables us to develop a compact finger-shaped GelForce for the robotic hand. GelForce that is developed on the basis of an elastic theory can be used to calculate surface traction fields using a conversion equation. However, this conversion equation cannot be analytically solved when the elastic body of the sensor has a complicated shape such as the shape of a finger. Therefore, we propose an observational method and construct a prototype of the finger-shaped GelForce. By using this prototype, we evaluate the basic performance of the finger-shaped GelForce. Then, we conduct a field test by performing grasping operations using a robotic hand. The results of this test show that using the observational method, the finger-shaped GelForce can be successfully used in a robotic hand.

  5. PHF20 regulates NF-κB signalling by disrupting recruitment of PP2A to p65

    PubMed Central

    Zhang, Tiejun; Park, Kyeong Ah; Li, Yuwen; Byun, Hee Sun; Jeon, Juhee; Lee, Yoonjung; Hong, Jang Hee; Kim, Jin Man; Huang, Song-Mei; Choi, Seung-Won; Kim, Sun-Hwan; Sohn, Kyung-Cheol; Ro, Hyunju; Lee, Ji Hoon; Lu, Tao; Stark, George R.; Shen, Han-Ming; Liu, Zheng-gang; Park, Jongsun; Hur, Gang Min

    2014-01-01

    Constitutive NF-κB activation in cancer cells is caused by defects in the signalling network responsible for terminating the NF-κB response. Here we report that plant homeodomain finger protein 20 maintains NF-κB in an active state in the nucleus by inhibiting the interaction between PP2A and p65. We show that plant homeodomain finger protein 20 induces canonical NF-κB signalling by increasing the DNA-binding activity of NF-κB subunit p65. In plant homeodomain finger protein 20-overexpressing cells, the termination of tumour necrosis factor-induced p65 phosphorylation is impaired whereas upstream signalling events triggered by tumour necrosis factor are unaffected. This effect strictly depends on the interaction between plant homeodomain finger protein 20 and methylated lysine residues of p65, which hinders recruitment of PP2A to p65, thereby maintaining p65 in a phosphorylated state. We further show that plant homeodomain finger protein 20 levels correlate with p65 phosphorylation levels in human glioma specimens. Our work identifies plant homeodomain finger protein 20 as a novel regulator of NF-κB activation and suggests that elevated expression of plant homeodomain finger protein 20 may drive constitutive NF-κB activation in some cancers. PMID:23797602

  6. Quantitative assessment of finger tapping characteristics in mild cognitive impairment, Alzheimer's disease, and Parkinson's disease.

    PubMed

    Roalf, David R; Rupert, Petra; Mechanic-Hamilton, Dawn; Brennan, Laura; Duda, John E; Weintraub, Daniel; Trojanowski, John Q; Wolk, David; Moberg, Paul J

    2018-06-01

    Fine motor impairments are common in neurodegenerative disorders, yet standardized, quantitative measurements of motor abilities are uncommonly used in neurological practice. Thus, understanding and comparing fine motor abilities across disorders have been limited. The current study compared differences in finger tapping, inter-tap interval, and variability in Alzheimer's disease (AD), Parkinson's disease (PD), mild cognitive impairment (MCI), and healthy older adults (HOA). Finger tapping was measured using a highly sensitive light-diode finger tapper. Total number of finger taps, inter-tap interval, and intra-individual variability (IIV) of finger tapping was measured and compared in AD (n = 131), PD (n = 63), MCI (n = 46), and HOA (n = 62), controlling for age and sex. All patient groups had fine motor impairments relative to HOA. AD and MCI groups produced fewer taps with longer inter-tap interval and higher IIV compared to HOA. The PD group, however, produced more taps with shorter inter-tap interval and higher IIV compared to HOA. Disease-specific changes in fine motor function occur in the most common neurodegenerative diseases. The findings suggest that alterations in finger tapping patterns are common in AD, MCI, and PD. In addition, the present results underscore the importance of motor dysfunction even in neurodegenerative disorders without primary motor symptoms.

  7. Transmission of vibration through gloves: effects of material thickness.

    PubMed

    Md Rezali, Khairil Anas; Griffin, Michael J

    2016-08-01

    It might be assumed that increasing the thickness of a glove would reduce the vibration transmitted to the hand. Three material samples from an anti-vibration glove were stacked to produce three thicknesses: 6.4, 12.8 and 19.2 mm. The dynamic stiffnesses of all three thicknesses, the apparent mass at the palm and the finger and the transmission of vibration to the palm and finger were measured. At frequencies from 20 to 350 Hz, the material reduced vibration at the palm but increased vibration at the finger. Increased thickness reduced vibration at the palm but increased vibration at the finger. The measured transmissibilities could be predicted from the material dynamic stiffness and the apparent mass of the palm and finger. Reducing the dynamic stiffness of glove material may increase or decrease the transmission of vibration, depending on the material, the frequency of vibration and the location of measurement (palm or finger). Practitioner Summary: Transmission of vibration through gloves depends on the dynamic response of the hand and the dynamic stiffness of glove material, which depends on material thickness. Measuring the transmission of vibration through gloves to the palm of the hand gives a misleading indication of the transmission of vibration to the fingers.

  8. Distractor objects affect fingers' angular distances but not fingers' shaping during grasping.

    PubMed

    Ansuini, Caterina; Tognin, Veronica; Turella, Luca; Castiello, Umberto

    2007-04-01

    The aim of the present study was to determine whether and how hand shaping was affected by the presence of a distractor object adjacent to the to-be-grasped object. Twenty subjects were requested to reach towards and grasp a 'convex' or a 'concave' object in the presence or absence of a distractor object either of the same or different shape than the target object. Flexion/extension at the metacarpal-phalangeal (MCP) and proximal interphalangeal joints of all digits, and abduction angle between digits were measured by resistive sensors embedded in a glove. The results indicate robust interference effects at the level of reach duration and the extent of fingers' abduction angles together with changes at the level of a single joint for the thumb. No distractor effects on individual fingers' joints except for the MCP of the middle and little fingers were found. These findings suggest that the presence of distractor object affects hand shaping in terms of fingers' abduction angles, but not at the level of 'shape dependent' fingers' angular excursions. Furthermore, they support the importance of the thumb for the guidance of selective reach-to-grasp movements. We discuss these results in the context of current theories proposed to explain the object selection processes underlying the control of hand action.

  9. Linkage Analysis of a Model Quantitative Trait in Humans: Finger Ridge Count Shows Significant Multivariate Linkage to 5q14.1

    PubMed Central

    Medland, Sarah E; Loesch, Danuta Z; Mdzewski, Bogdan; Zhu, Gu; Montgomery, Grant W; Martin, Nicholas G

    2007-01-01

    The finger ridge count (a measure of pattern size) is one of the most heritable complex traits studied in humans and has been considered a model human polygenic trait in quantitative genetic analysis. Here, we report the results of the first genome-wide linkage scan for finger ridge count in a sample of 2,114 offspring from 922 nuclear families. Both univariate linkage to the absolute ridge count (a sum of all the ridge counts on all ten fingers), and multivariate linkage analyses of the counts on individual fingers, were conducted. The multivariate analyses yielded significant linkage to 5q14.1 (Logarithm of odds [LOD] = 3.34, pointwise-empirical p-value = 0.00025) that was predominantly driven by linkage to the ring, index, and middle fingers. The strongest univariate linkage was to 1q42.2 (LOD = 2.04, point-wise p-value = 0.002, genome-wide p-value = 0.29). In summary, the combination of univariate and multivariate results was more informative than simple univariate analyses alone. Patterns of quantitative trait loci factor loadings consistent with developmental fields were observed, and the simple pleiotropic model underlying the absolute ridge count was not sufficient to characterize the interrelationships between the ridge counts of individual fingers. PMID:17907812

  10. Design of a Reconfigurable Robotic System for Flexoextension Fitted to Hand Fingers Size.

    PubMed

    Aguilar-Pereyra, J Felipe; Castillo-Castaneda, Eduardo

    2016-01-01

    Due to the growing demand for assistance in rehabilitation therapies for hand movements, a robotic system is proposed to mobilize the hand fingers in flexion and extension exercises. The robotic system is composed by four, type slider-crank, mechanisms that have the ability to fit the user fingers length from the index to the little finger, through the adjustment of only one link for each mechanism. The trajectory developed by each mechanism corresponds to the natural flexoextension path of each finger. The amplitude of the rotations for metacarpophalangeal joint (MCP) and proximal interphalangeal joint (PIP) varies from 0 to 90° and the distal interphalangeal joint (DIP) varies from 0 to 60°; the joint rotations are coordinated naturally. The four R-RRT mechanisms orientation allows a 15° abduction movement for index, ring, and little fingers. The kinematic analysis of this mechanism was developed in order to assure that the displacement speed and smooth acceleration into the desired range of motion and the simulation results are presented. The reconfiguration of mechanisms covers about 95% of hand sizes of a group of Mexican adult population. Maximum trajectory tracking error is less than 3% in full range of movement and it can be compensated by the additional rotation of finger joints without injury to the user.

  11. Stretch force guides finger-like pattern of bone formation in suture

    PubMed Central

    Kou, Xiao-Xing; Zhang, Ci; Zhang, Yi-Mei; Cui, Zhen; Wang, Xue-Dong; Liu, Yan; Liu, Da-Wei; Zhou, Yan-Heng

    2017-01-01

    Mechanical tension is widely applied on the suture to modulate the growth of craniofacial bones. Deeply understanding the features of bone formation in expanding sutures could help us to improve the outcomes of clinical treatment and avoid some side effects. Although there are reports that have uncovered some biological characteristics, the regular pattern of sutural bone formation in response to expansion forces is still unknown. Our study was to investigate the shape, arrangement and orientation of new bone formation in expanding sutures and explore related clinical implications. The premaxillary sutures of rat, which histologically resembles the sutures of human beings, became wider progressively under stretch force. Micro-CT detected new bones at day 3. Morphologically, these bones were forming in a finger-like pattern, projecting from the maxillae into the expanded sutures. There were about 4 finger-like bones appearing on the selected micro-CT sections at day 3 and this number increased to about 18 at day 7. The average length of these projections increased from 0.14 mm at day 3 to 0.81 mm at day 7. The volume of these bony protuberances increased to the highest level of 0.12 mm3 at day 7. HE staining demonstrated that these finger-like bones had thick bases connecting with the maxillae and thin fronts stretching into the expanded suture. Nasal sections had a higher frequency of finger-like bones occuring than the oral sections at day 3 and day 5. Masson-stained sections showed stretched fibers embedding into maxillary margins. Osteocalcin-positive osteoblasts changed their shapes from cuboidal to spindle and covered the surfaces of finger-like bones continuously. Alizarin red S and calcein deposited in the inner and outer layers of finger-like bones respectively, which showed that longer and larger bones formed on the nasal side of expanded sutures compared with the oral side. Interestingly, these finger-like bones were almost paralleling with the direction of stretch force. Inclined force led to inclined finger-like bones formation and deflection of bilateral maxillae. Additionally, heavily compressive force caused fracture of finger-like bones in the sutures. These data together proposed the special finger-like pattern of bone formation in sutures guided by stretch force, providing important implications for maxillary expansion. PMID:28472133

  12. Haemodynamic changes in ipsilateral and contralateral fingers caused by acute exposures to hand transmitted vibration.

    PubMed Central

    Bovenzi, M; Griffin, M J

    1997-01-01

    OBJECTIVES: To investigate changes in digital circulation during and after exposure to hand transmitted vibration. By studying two frequencies and two magnitudes of vibration, to investigate the extent to which haemodynamic changes depend on the vibration frequency, the vibration acceleration, and the vibration velocity. METHODS: Finger skin temperature (FST), finger blood flow (FBF), and finger systolic pressure were measured in the fingers of both hands in eight healthy men. Indices of digital vasomotor tone-such as critical closing pressure and vascular resistance-were estimated by pressure-flow curves obtained with different hand heights. With a static load of 10 N, the right hand was exposed for 30 minutes to each of the following root mean squared (rms) acceleration magnitudes and frequencies of vertical vibration: 22 m.s-2 at 31.5 Hz, 22 m.s-2 at 125 Hz, and 87 m.s-2 at 125 Hz. A control condition consisted of exposure to the static load only. The measures of digital circulation and vasomotor tone were taken before exposure to the vibration and the static load, and at 0, 20, 40, and 60 minutes after the end of each exposure. RESULTS: Exposure to static load caused no significant changes in FST, FBF, or indices of vasomotor tone in either the vibrated right middle finger or the non-vibrated left middle finger. In both fingers, exposure to vibration of 125 Hz and 22 m.s-2 produced a greater reduction in FBF and a greater increase in vasomotor tone than did vibration of 31.5 Hz and 22 m.s-2. In the vibrated right finger, exposure to vibration of 125 Hz and 87 m.s-2 provoked an immediate vasodilation which was followed by vasoconstriction during recovery. The non-vibrated left finger showed a significant increase in vasomotor tone throughout the 60 minute period after the end of vibration exposure. CONCLUSIONS: The digital circulatory response to acute vibration depends upon the magnitude and frequency of the vibration stimulus. Vasomotor mechanisms, mediated both centrally and locally, are involved in the reaction of digital vessels to acute vibration. The pattern of the haemodynamic changes in the fingers exposed to the vibration frequencies used in this study do not seem to support the frequency weighting assumed in the current international standard ISO 5349. PMID:9326160

  13. Competition of wormholes during the evolution of cave passages

    NASA Astrophysics Data System (ADS)

    Gabrovsek, Franci; Dreybrodt, Wolfgang

    2017-04-01

    Reactive fronts in two-dimensional plane parallel fractures, with constant head difference between input and output and with diffusion controlled first order reaction rates R = keff ṡ (Ceq - C), where keff = k ṡ (1 + ka/6D)-1, are instable to infinitesimal perturbations in fracture aperture width (1), causing spontaneous fingering of the reactive front resulting in the formation of wormholes. C is the actual concentration and Ceq the equilibrium concentration, a, is the actual aperture width of the fracture , and D the constant of molecular diffusion. Fingering happens also in plane-parallel rough fractures where it is triggered by the existence of statistically more favorable pathways. The same behavior is observed in rectangular two-dimensional networks of "one-dimensional" smooth fractures used in modeling the evolution of caves in soluble rock (2). Here the formation of caves can be regarded as the evolution of wormholes along the two-dimensional network. Once fingering has been triggered, either by instability or by roughness, many small fingers compete with each other and only a few survive. Here we investigate the competition between two seeded fingers in initially homogeneous fracture networks with identical aperture width of all fractures and also in inhomogeneous ones where the aperture widths are distributed log normally. In both cases our modeling reveals the rules of competition: By instability one of the fingers grows faster than its competitor therefore penetrating somewhat deeper. As a consequence the hydraulic head at its tip is higher than that close to the tip of the shorter finger. Therefore the fractures connecting the tip regions of both fingers carry flow from the deep finger to the tip region of its competitor. This cross-flow is replaced by increasing inflow of aggressive solution into the input of the winner, enhancing further dissolution and growth. On the other hand the cross-flow increases the head at the tip of the losing finger, and consequently decreases inflow of aggressive solution into it, thus inhibiting its further evolution. This mechanism supports further growth of the winner (wormhole) and stops the growth of its competitor. Similar competition happens in the case of several fingers competing. In any case we observe flow from the winning fingers to the loosing ones. The communication between the competitors is always established by cross flow between its tip regions. We will present various scenarios of wormhole formation, which demonstrate details of the competition of fingers arising from either the reactive instability or from the statistical distribution of fracture aperture widths. In conclusion we find that the initiation of wormholes results either from instability or from the statistical distribution of favorable pathways. Once growth of fingers has been initiated the evolution of the wormhole patterns becomes deterministic. (1) Szymczak, P., and A.J.C. Ladd (2011), The initial stages of cave formation: Beyond the one-dimensional paradigm, Earth Planet. Sci. Lett. 301, 424-432 (2) Dreybrodt, W., Gabrovšek, F., Romanov, D.(2005) Processes of Speleogenesis: A Modeling Approach. ZRC Publishing, Karst Research Institute at ZRC SAZU, Ljubljana

  14. Cheiloscopy and dactyloscopy: Do they dictate personality patterns?

    PubMed

    Abidullah, Mohammed; Kumar, M Naveen; Bhorgonde, Kavita D; Reddy, D Shyam Prasad

    2015-01-01

    Cheiloscopy and dactyloscopy, both are well-established forensic tools used in individual identification in any scenario be it a crime scene or civil cause. Like finger prints, lip prints are unique and distinguishable for every individual. But their relationship to personality types has not been established excepting the hypothesis stating that finger prints could explain these personality patterns. The study was aimed to record and correlate the lip and finger prints with that of character/personality of a person. The lip and finger prints and character of a person were recorded and the data obtained was subjected for statistical analysis, especially for Pearson's Chi-square test and correlation/association between the groups was also studied. The study sample comprised of 200 subjects, 100 males and 100 females, aged between 18 and 30 years. For recording lip prints, brown/pink-colored lipstick was applied on the lips and the subjects were asked to spread uniformly over the lips. Lip prints were traced in the normal rest position on a plain white bond paper. For recording the finger prints, imprints of the fingers were taken on a plain white bond paper using ink pad. The collected prints were visualized using magnifying lens. To record the character of person, a pro forma manual for multivariable personality inventory by Dr. BC Muthayya was used. Data obtained was subjected for statistical analysis, especially for Pearson's Chi-square test and correlation/association between the groups was also studied. In males, predominant lip pattern recorded was Type I with whorls-type finger pattern and the character being ego ideal, pessimism, introvert, and dogmatic; whereas in females, predominant lip pattern recorded was Type II with loops-type finger pattern and the character being neurotic, need achievers, and dominant. Many studies on lip pattern, finger pattern, palatal rugae, etc., for individual identification and gender determination exist, but correlative studies are scanty. This is the first study done on correlating patterns, that is, lip and finger pattern with the character of a person. With this study we conclude that this correlation can be used as an adjunct in the investigatory process in forensic sciences.

  15. A three-fingered, touch-sensitive, metrological micro-robotic assembly tool

    NASA Astrophysics Data System (ADS)

    Torralba, Marta; Hastings, D. J.; Thousand, Jeffery D.; Nowakowski, Bartosz K.; Smith, Stuart T.

    2015-12-01

    This article describes a metrological, robotic hand to manipulate and measure micrometer size objects. The presented work demonstrates not only assembly operations, but also positioning control and metrology capability. Sample motion is achieved by a commercial positioning stage, which provides XYZ-displacements for assembly of components. A designed and manufactured gripper tool that incorporates 21 degrees-of-freedom for independent alignment of actuators, sensors, and the three fingers of this hand is presented. These fingers can be opened and closed by piezoelectric actuators through levered flexures providing an 80 μm displacement range measured with calibrated opto-interrupter based, knife-edge sensors. The operational ends of the fingers comprise of a quartz tuning fork with a 7 μm diameter 3.2 mm long carbon fiber extending from the end of one tuning fork tine. Finger-tip force-sensing is achieved by the monitoring of individual finger resonances typically at around 32 kHz. Experimental results included are focused on probe performance analysis. Pick and place operation using the three fingers is demonstrated with all fingers being continuously oscillated, a capability not possible with the previous single or two finger tweezer type designs. By monitoring electrical feedback during pick and place operations, changes in the response of the three probes demonstrate the ability to identify both grab and release operations. Component metrology has been assessed by contacting different micro-spheres of diameters 50(±7.5) μm, 135(±20) μm, and 140(±20) μm. These were measured by the micro robot to have diameters of 67, 133, and 126 μm respectively with corresponding deviations of 4.2, 4.9, and 4.3 μm. This deviation in the measured results was primarily due to the manual, joystick-based, contacting of the fingers, difficulties associated with centering the components to the axis of the hand, and lower contact sensitivity for the smallest sphere. Finally, assemblies of spheres onto the edge of a razor blade plus assembly of spherical contact probes for micro-meter scale coordinate measurement applications are presented.

  16. Metacarpal synostosis: treatment with a longitudinal osteotomy and bone graft substitute interposition.

    PubMed

    Gottschalk, Hilton P; Bednar, Michael S; Moor, Molly; Light, Terry R

    2012-10-01

    To describe a case series of congenital metacarpal synostosis treated with longitudinal osteotomy and bone graft substitute interposition. We retrospectively reviewed charts of all patients with metacarpal synostosis treated with a longitudinal osteotomy and bone graft substitute interposition at 2 institutions. Radiographic and clinical appearances were analyzed at initial diagnosis, intraoperatively, and at last follow-up. A total of 10 patients (14 hands) met the inclusion criteria. Six patients (8 hands) demonstrated ring-little finger metacarpal synostosis and 4 patients (6 hands) had a middle-ring finger metacarpal synostosis. The median age at operation was 5 years (range, 2-16 y). Follow-up ranged from 1 to 14 years (average, 3 y). Associated hand anomalies included polydactyly, symbrachydactyly, and clinodactyly. Before surgery, the little finger proximal phalanx was angulated away from the middle finger metacarpal on average 46° (range, 26°-60°), and the angulation between the middle and the ring fingers averaged 43° (range, 26°-50°). Postoperative correction at 1 year was statistically significant for both ring-little finger metacarpal synostosis, average 23° (range, 10°-30°), and middle-ring finger metacarpal synostosis, average 16° (range, 5°-44°). Recurrence of digital abduction was evident in 2 patients who had middle-ring finger metacarpal synostosis. Metacarpal synostosis is an uncommon congenital hand anomaly characterized by the coalescence of 2 adjacent metacarpals. In the most common form, the ring and little finger metacarpals are associated with abduction of the small finger in an awkward position. Use of the described technique is safe and effective, yet concerns remain regarding mild persistent angulation and risk of recurrence. Congenital metacarpal synostosis may be effectively treated with a longitudinal osteotomy, realignment of component metacarpals, and interposition of bone graft substitute. When the procedure is performed at a young age, we recommend follow-up until skeletal maturity to identify recurrence of the deformity. Therapeutic IV. Copyright © 2012 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  17. Radial viscous fingering of hot asthenosphere within the Icelandic plume beneath the North Atlantic Ocean

    NASA Astrophysics Data System (ADS)

    Schoonman, C. M.; White, N. J.; Pritchard, D.

    2017-06-01

    The Icelandic mantle plume has had a significant influence on the geologic and oceanographic evolution of the North Atlantic Ocean during Cenozoic times. Full-waveform tomographic imaging of this region shows that the planform of this plume has a complex irregular shape with significant shear wave velocity anomalies lying beneath the lithospheric plates at a depth of 100-200 km. The distribution of these anomalies suggests that about five horizontal fingers extend radially beneath the fringing continental margins. The best-imaged fingers lie beneath the British Isles and beneath western Norway where significant departures from crustal isostatic equilibrium have been measured. Here, we propose that these radial fingers are generated by a phenomenon known as the Saffman-Taylor instability. Experimental and theoretical analyses show that fingering occurs when a less viscous fluid is injected into a more viscous fluid. In radial, miscible fingering, the wavelength and number of fingers are controlled by the mobility ratio (i.e. the ratio of viscosities), by the Péclet number (i.e. the ratio of advective and diffusive transport rates), and by the thickness of the horizontal layer into which fluid is injected. We combine shear wave velocity estimates with residual depth measurements around the Atlantic margins to estimate the planform distribution of temperature and viscosity within a horizontal asthenospheric layer beneath the lithospheric plate. Our estimates suggest that the mobility ratio is at least 20-50, that the Péclet number is O (104), and that the asthenospheric channel is 100 ± 20 km thick. The existence and planform of fingering is consistent with experimental observations and with theoretical arguments. A useful rule of thumb is that the wavelength of fingering is 5 ± 1 times the thickness of the horizontal layer. Our proposal has been further tested by examining plumes of different vigor and planform (e.g. Hawaii, Cape Verde, Yellowstone). Our results support the notion that dynamic topography of the Earth's surface can be influenced by fast, irregular horizontal flow within thin, but rapidly evolving, asthenospheric fingers.

  18. The distribution of silty soils in the Grayling Fingers region of Michigan: Evidence for loess deposition onto frozen ground

    NASA Astrophysics Data System (ADS)

    Schaetzl, Randall J.

    2008-12-01

    This paper presents textural, geochemical, mineralogical, soils, and geomorphic data on the sediments of the Grayling Fingers region of northern Lower Michigan. The Fingers are mainly comprised of glaciofluvial sediment, capped by sandy till. The focus of this research is a thin silty cap that overlies the till and outwash; data presented here suggest that it is local-source loess, derived from the Port Huron outwash plain and its down-river extension, the Mainstee River valley. The silt is geochemically and texturally unlike the glacial sediments that underlie it and is located only on the flattest parts of the Finger uplands and in the bottoms of upland, dry kettles. On sloping sites, the silty cap is absent. The silt was probably deposited on the Fingers during the Port Huron meltwater event; a loess deposit roughly 90 km down the Manistee River valley has a comparable origin. Data suggest that the loess was only able to persist on upland surfaces that were either closed depressions (currently, dry kettles) or flat because of erosion during and after loess deposition. Deep, low-order tributary gullies (almost ubiquitous on Finger sideslopes) could only have formed by runoff, and soil data from them confirm that the end of gully formation (and hence, the end of runoff) was contemporaneous with the stabilization of the outwash surfaces in the lowlands. Therefore, runoff from the Finger uplands during the loess depositional event is the likely reason for the absence of loess at sites in the Fingers. Because of the sandy nature and high permeability of the Fingers' sediments, runoff on this scale could only have occurred under frozen ground conditions. Frozen ground and windy conditions in the Fingers at the time of the Port Huron advance is likely because the area would have been surrounded by ice on roughly three sides. This research (1) shows that outwash plains and meltwater streams of only medium size can be significant loess sources and (2) is the first to present evidence for frozen ground conditions in this part of the upper Midwest.

  19. Foster replantation of fingertip using neighbouring digital artery in a young child.

    PubMed

    Xu, Jing-Hong; Gao, Zheng-Jun; Yao, Jing-Ming; Tan, Wei-Qiang; Dawreeawo, Javed

    2010-06-01

    Reconstruction of an amputated fingertip in a young child demands special techniques for success. We report a 2.5-year-old female patient with an amputated left index fingertip with the vascular defect being too severe to perform the usual replantation. Comparing several methods, we used the neighbouring digital artery as the feeding artery to perform foster replantation. Finally, the patient was satisfied with the appearance and function of her fingers. The clinical case, techniques, results are described and discussed. We consider it a useful technique, especially for those with a rather severe vascular defect. A 2.5-year-old girl suffered a crush amputation of the left index fingertip. Only the flexor tendon of the amputated fingertip was connected to the proximal finger tissue and the blood supply was completely lost (Figure 1). The distal amputated fingertip was fixed using Kirschner wire under general anaesthesia. Then, microsurgery operation was carried out immediately to replant this amputated fingertip. Both ulnar and radial digital arteries were avulsed, while the dorsal vein was intact and the digital nerve was also surviving. The integrity of blood vessels was too traumatised to connect to the proximal part. In the case of the distal part of the ulnar artery of the injured index finger, the blood supply was established by anastomosing the distal end of the amputated tip and the radial artery of the middle finger, which was the feeding artery (Figure 2). A 11/0 nylon suture was used. The dorsal vein and digital nerve were repaired by means of microsurgical anastomosis. The wound was covered with the dorsal skin of the middle finger and the palmar skin of the index finger to form a skin pedicle, and then, immobility of the two fingers was maintained to prevent avulsion. The index tip obtained good blood supply and survived completely (Figure 3). Detachment of the index and middle finger was performed after 3 weeks, and both of the fingers showed good blood supply (Figure 4). The appearance and function of the index and middle fingers were satisfactory 3 months postoperatively. Copyright 2009 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. Effect of the linkers between the zinc fingers in zinc finger protein 809 on gene silencing and nuclear localization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ichida, Yu, E-mail: ichida-y@ncchd.go.jp; Utsunomiya, Yuko; Onodera, Masafumi

    2016-03-18

    Zinc finger protein 809 (ZFP809) belongs to the Kruppel-associated box-containing zinc finger protein (KRAB-ZFP) family and functions in repressing the expression of Moloney murine leukemia virus (MoMLV). ZFP809 binds to the primer-binding site (PBS)located downstream of the MoMLV-long terminal repeat (LTR) and induces epigenetic modifications at integration sites, such as repressive histone modifications and de novo DNA methylation. KRAB-ZFPs contain consensus TGEKP linkers between C2H2 zinc fingers. The phosphorylation of threonine residues within linkers leads to the inactivation of zinc finger binding to target sequences. ZFP809 also contains consensus linkers between zinc fingers. However, the function of ZFP809 linkers remainsmore » unknown. In the present study, we constructed ZFP809 proteins containing mutated linkers and examined their ability to silence transgene expression driven by MLV, binding ability to MLV PBS, and cellular localization. The results of the present study revealed that the linkers affected the ability of ZFP809 to silence transgene expression. Furthermore, this effect could be partly attributed to changes in the localization of ZFP809 proteins containing mutated linkers. Further characterization of ZFP809 linkers is required for understanding the functions and features of KRAB-ZFP-containing linkers. - Highlights: • ZFP809 has three consensus linkers between the zinc fingers. • Linkers are required for ZFP809 to silence transgene expression driven by MLV-LTR. • Linkers affect the precise nuclear localization of ZFP809.« less

  1. EEG resolutions in detecting and decoding finger movements from spectral analysis

    PubMed Central

    Xiao, Ran; Ding, Lei

    2015-01-01

    Mu/beta rhythms are well-studied brain activities that originate from sensorimotor cortices. These rhythms reveal spectral changes in alpha and beta bands induced by movements of different body parts, e.g., hands and limbs, in electroencephalography (EEG) signals. However, less can be revealed in them about movements of different fine body parts that activate adjacent brain regions, such as individual fingers from one hand. Several studies have reported spatial and temporal couplings of rhythmic activities at different frequency bands, suggesting the existence of well-defined spectral structures across multiple frequency bands. In the present study, spectral principal component analysis (PCA) was applied on EEG data, obtained from a finger movement task, to identify cross-frequency spectral structures. Features from identified spectral structures were examined in their spatial patterns, cross-condition pattern changes, detection capability of finger movements from resting, and decoding performance of individual finger movements in comparison to classic mu/beta rhythms. These new features reveal some similar, but more different spatial and spectral patterns as compared with classic mu/beta rhythms. Decoding results further indicate that these new features (91%) can detect finger movements much better than classic mu/beta rhythms (75.6%). More importantly, these new features reveal discriminative information about movements of different fingers (fine body-part movements), which is not available in classic mu/beta rhythms. The capability in decoding fingers (and hand gestures in the future) from EEG will contribute significantly to the development of non-invasive BCI and neuroprosthesis with intuitive and flexible controls. PMID:26388720

  2. Direct Coaptation of the Phrenic Nerve With the Posterior Division of the Lower Trunk to Restore Finger and Elbow Extension Function in Patients With Total Brachial Plexus Injuries.

    PubMed

    Wang, Shu-feng; Li, Peng-cheng; Xue, Yun-hao; Zou, Ji-yao; Li, Wen-jun; Li, Yucheng

    2016-02-01

    To overcome the mismatch in nerve sizes in phrenic nerve transfer to the radial nerve for elbow and finger extension reanimation for patients with total brachial plexus injuries (TBPI), a selective neurotization procedure was designed. To investigate the long-term results of phrenic nerve transfer to the posterior division of the lower trunk with direct coaptation in restoring elbow and finger extension after TBPI. Phrenic nerve was transferred to and directly coapted with the posterior division of the lower trunk in 27 patients with TBPI. Seven patients were <18 years old (adolescent group), and the remaining 20 patients ≥18 years (adult group). Postoperative mean follow-up period was 54 ± 9 months (range, 48-85 months). The motor function attained M3 or greater in 81.5% of patients for elbow extension and in 48% of patients for finger extension. The percentage of patients who regained M3 or greater muscle power of finger extension in the adolescent group and the adult group was 71.4%, and 40%, respectively. Meanwhile, 85.7% in the adolescent group and 80% in the adult group achieved M3 or greater muscle power of elbow extension. There were no significant differences between the 2 groups. The elbow extension and finger extension were synchronous contractions and did not become independent of respiratory effort. This procedure simultaneously and effectively restores the function of elbow and finger extension in patients after TBPI. However, the patients could not do elbow and finger extension separately.

  3. Influence of finger and mouth action observation on random number generation: an instance of embodied cognition for abstract concepts.

    PubMed

    Grade, Stéphane; Badets, Arnaud; Pesenti, Mauro

    2017-05-01

    Numerical magnitude and specific grasping action processing have been shown to interfere with each other because some aspects of numerical meaning may be grounded in sensorimotor transformation mechanisms linked to finger grip control. However, how specific these interactions are to grasping actions is still unknown. The present study tested the specificity of the number-grip relationship by investigating how the observation of different closing-opening stimuli that might or not refer to prehension-releasing actions was able to influence a random number generation task. Participants had to randomly produce numbers after they observed action stimuli representing either closure or aperture of the fingers, the hand or the mouth, or a colour change used as a control condition. Random number generation was influenced by the prior presentation of finger grip actions, whereby observing a closing finger grip led participants to produce small rather than large numbers, whereas observing an opening finger grip led them to produce large rather than small numbers. Hand actions had reduced or no influence on number production; mouth action influence was restricted to opening, with an overproduction of large numbers. Finally, colour changes did not influence number generation. These results show that some characteristics of observed finger, hand and mouth grip actions automatically prime number magnitude, with the strongest effect for finger grasping. The findings are discussed in terms of the functional and neural mechanisms shared between hand actions and number processing, but also between hand and mouth actions. The present study provides converging evidence that part of number semantics is grounded in sensory-motor mechanisms.

  4. Study of the tactile perception of bathroom tissues: Comparison between the sensory evaluation by a handfeel panel and a tribo-acoustic artificial finger.

    PubMed

    Thieulin, C; Pailler-Mattei, C; Vargiolu, R; Lancelot, S; Zahouani, H

    2017-02-01

    Tactile perception is one of the sensorial modes most stimulated by our daily environment. In particular, perceived softness is an important parameter for judging the sensory quality of surfaces and fabrics. Unfortunately, its assessment greatly depends on the tactile sense of each person, which in turn depends on many factors. Currently, the predominant method for evaluating the tactile perception of fabrics is the human handfeel panel. This qualitative approach does not permit the quantitative measure of touch feel perception. In this study, we present a new artificial finger device to investigate the tactile sensing of ten bathroom tissues. It enables simultaneously measuring the friction and vibrations caused when sliding an artificial finger on the surface of the tissue. The comparison between the results obtained with the artificial finger and the tactile perception evaluated using a handfeel panel showed that the artificial finger is able to separate the two parts of the tactile perception of bathroom tissues: softness and surface texture (velvetiness). The statistical analysis suggests that there is a good correlation between the vibrations measured with the artificial finger and the softness evaluated by the panel. It then shows that the friction measured by the artificial finger is related to the surface texture of a bathroom tissue. The ability of the artificial finger to mimic human touch is demonstrated. Finally, a Principal Component Analysis orders the signatures of the tactile perception of the bathroom tissues in four different groups. Copyright © 2016. Published by Elsevier B.V.

  5. Stable expression of mtlD gene imparts multiple stress tolerance in finger millet.

    PubMed

    Hema, Ramanna; Vemanna, Ramu S; Sreeramulu, Shivakumar; Reddy, Chandrasekhara P; Senthil-Kumar, Muthappa; Udayakumar, Makarla

    2014-01-01

    Finger millet is susceptible to abiotic stresses, especially drought and salinity stress, in the field during seed germination and early stages of seedling development. Therefore developing stress tolerant finger millet plants combating drought, salinity and associated oxidative stress in these two growth stages is important. Cellular protection through osmotic adjustment and efficient free radical scavenging ability during abiotic stress are important components of stress tolerance mechanisms in plants. Mannitol, an osmolyte, is known to scavenge hydroxyl radicals generated during various abiotic stresses and thereby minimize stress damage in several plant species. In this study transgenic finger millet plants expressing the mannitol biosynthetic pathway gene from bacteria, mannitol-1-phosphate dehydrogenase (mtlD), were developed through Agrobacterium tumefaciens-mediated genetic transformation. mtlD gene integration in the putative transgenic plants was confirmed by Southern blot. Further, performance of transgenic finger millet under drought, salinity and oxidative stress was studied at plant level in T1 generation and in T1 and T2 generation seedlings. Results from these experiments showed that transgenic finger millet had better growth under drought and salinity stress compared to wild-type. At plant level, transgenic plants showed better osmotic adjustment and chlorophyll retention under drought stress compared to the wild-type. However, the overall increase in stress tolerance of transgenics for the three stresses, especially for oxidative stress, was only marginal compared to other mtlD gene expressing plant species reported in the literature. Moreover, the Agrobacterium-mediated genetic transformation protocol developed for finger millet in this study can be used to introduce diverse traits of agronomic importance in finger millet.

  6. Cortical activity predicts good variation in human motor output.

    PubMed

    Babikian, Sarine; Kanso, Eva; Kutch, Jason J

    2017-04-01

    Human movement patterns have been shown to be particularly variable if many combinations of activity in different muscles all achieve the same task goal (i.e., are goal-equivalent). The nervous system appears to automatically vary its output among goal-equivalent combinations of muscle activity to minimize muscle fatigue or distribute tissue loading, but the neural mechanism of this "good" variation is unknown. Here we use a bimanual finger task, electroencephalography (EEG), and machine learning to determine if cortical signals can predict goal-equivalent variation in finger force output. 18 healthy participants applied left and right index finger forces to repeatedly perform a task that involved matching a total (sum of right and left) finger force. As in previous studies, we observed significantly more variability in goal-equivalent muscle activity across task repetitions compared to variability in muscle activity that would not achieve the goal: participants achieved the task in some repetitions with more right finger force and less left finger force (right > left) and in other repetitions with less right finger force and more left finger force (left > right). We found that EEG signals from the 500 milliseconds (ms) prior to each task repetition could make a significant prediction of which repetitions would have right > left and which would have left > right. We also found that cortical maps of sites contributing to the prediction contain both motor and pre-motor representation in the appropriate hemisphere. Thus, goal-equivalent variation in motor output may be implemented at a cortical level.

  7. Experimental Evaluation of a Braille-Reading-Inspired Finger Motion Adaptive Algorithm.

    PubMed

    Ulusoy, Melda; Sipahi, Rifat

    2016-01-01

    Braille reading is a complex process involving intricate finger-motion patterns and finger-rubbing actions across Braille letters for the stimulation of appropriate nerves. Although Braille reading is performed by smoothly moving the finger from left-to-right, research shows that even fluent reading requires right-to-left movements of the finger, known as "reversal". Reversals are crucial as they not only enhance stimulation of nerves for correctly reading the letters, but they also show one to re-read the letters that were missed in the first pass. Moreover, it is known that reversals can be performed as often as in every sentence and can start at any location in a sentence. Here, we report experimental results on the feasibility of an algorithm that can render a machine to automatically adapt to reversal gestures of one's finger. Through Braille-reading-analogous tasks, the algorithm is tested with thirty sighted subjects that volunteered in the study. We find that the finger motion adaptive algorithm (FMAA) is useful in achieving cooperation between human finger and the machine. In the presence of FMAA, subjects' performance metrics associated with the tasks have significantly improved as supported by statistical analysis. In light of these encouraging results, preliminary experiments are carried out with five blind subjects with the aim to put the algorithm to test. Results obtained from carefully designed experiments showed that subjects' Braille reading accuracy in the presence of FMAA was more favorable then when FMAA was turned off. Utilization of FMAA in future generation Braille reading devices thus holds strong promise.

  8. Polyester non-woven fabric finger cover as a TRUCT Braille reading assistance tool for Braille learners.

    PubMed

    Doi, Kouki; Fujimoto, Hiroshi

    2007-11-01

    Transparent resinous ultraviolet-curing type (TRUCT) Braille signs are becoming more and more popular in Japan, especially when they are printed together with visual characters. These signs are made by screen printing, a technique that can be applied to various base materials, such as paper, metal, and plastic. TRUCT Braille signs have begun to be used in public facilities, such as on tactile maps and on handrails. Naturally, it is expected that Braille beginners will utilize these signs. However, it has been pointed out that the friction between the forefinger and the base material may affect reading accuracy and speed. In this study, we developed a finger cover made of soft, thin polyester non-woven fabric to reduce friction during Braille reading. We also carried out a study to investigate the effect of its use. The subjects were 12 Braille learners with acquired visual impairment, who were asked to read randomly selected characters with and without the finger cover. The results showed that most participants could read TRUCT Braille significantly faster and more accurately with a finger cover than without it, regardless of the base material and dot height. This result suggests that wearing the finger cover enables Braille learners to read TRUCT Braille more efficiently. The finger cover can be used as a Braille reading assistance tool for Braille learners. An additional, health-related advantage of the finger cover is that the forefinger remains clean. We expect that the finger cover will be in practical use in Japan within 1 or 2 years.

  9. Experimental Evaluation of a Braille-Reading-Inspired Finger Motion Adaptive Algorithm

    PubMed Central

    2016-01-01

    Braille reading is a complex process involving intricate finger-motion patterns and finger-rubbing actions across Braille letters for the stimulation of appropriate nerves. Although Braille reading is performed by smoothly moving the finger from left-to-right, research shows that even fluent reading requires right-to-left movements of the finger, known as “reversal”. Reversals are crucial as they not only enhance stimulation of nerves for correctly reading the letters, but they also show one to re-read the letters that were missed in the first pass. Moreover, it is known that reversals can be performed as often as in every sentence and can start at any location in a sentence. Here, we report experimental results on the feasibility of an algorithm that can render a machine to automatically adapt to reversal gestures of one’s finger. Through Braille-reading-analogous tasks, the algorithm is tested with thirty sighted subjects that volunteered in the study. We find that the finger motion adaptive algorithm (FMAA) is useful in achieving cooperation between human finger and the machine. In the presence of FMAA, subjects’ performance metrics associated with the tasks have significantly improved as supported by statistical analysis. In light of these encouraging results, preliminary experiments are carried out with five blind subjects with the aim to put the algorithm to test. Results obtained from carefully designed experiments showed that subjects’ Braille reading accuracy in the presence of FMAA was more favorable then when FMAA was turned off. Utilization of FMAA in future generation Braille reading devices thus holds strong promise. PMID:26849058

  10. Evaluation of the Sensitivity and Specificity of the New Clinical Diagnostic and Classification Criteria for Kashin-Beck Disease, an Endemic Osteoarthritis, in China.

    PubMed

    Yu, Fang Fang; Ping, Zhi Guang; Yao, Chong; Wang, Zhi Wen; Wang, Fu Qi; Guo, Xiong

    2017-02-01

    This study aimed to evaluate the sensitivity and specificity of the new clinical diagnostic and classification criteria for Kashin-Beck disease (KBD) using six clinical markers: flexion of the distal part of fingers, deformed fingers, enlarged finger joints, shortened fingers, squat down, and dwarfism. One-third of the total population in Linyou County was sampled by stratified random sampling. The survey included baseline characteristics and clinical diagnoses, and the sensitivity and specificity of the new criteria was evaluated. We identified 3,459 KBD patients, of which 69 had early stage KBD, 1,952 had stage I, 1,132 had stage II, and 306 had stage III. A screening test classified enlarged finger joints as stage I KBD, with a sensitivity and specificity of 0.978 and 0.045, respectively. Shortened fingers were classified as stage II KBD, with a sensitivity and specificity of 0.969 and 0.844, respectively, and dwarfism was classified as stage III KBD with a sensitivity and specificity of 0.951 and 0.992, respectively. Serial screening test revealed that the new clinical classification of KBD classified stages I, II, and III KBD with sensitivities of 0.949, 0.945, and 0.925 and specificities of 0.967, 0.970, and 0.993, respectively. The screening tests revealed that enlarged finger joints, shortened fingers, and dwarfism were appropriate markers for the clinical diagnosis and classification of KBD with high sensitivity and specificity. Copyright © 2017 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

  11. Arrhythmokinesis is evident during unimanual not bimanual finger tapping in Parkinson's disease.

    PubMed

    Trager, Megan H; Velisar, Anca; Koop, Mandy Miller; Shreve, Lauren; Quinn, Emma; Bronte-Stewart, Helen

    2015-01-01

    Arrhythmokinesis, the variability in repetitive movements, is a fundamental feature of Parkinson's disease (PD). We hypothesized that unimanual repetitive alternating finger tapping (AFT) would reveal more arrhythmokinesis compared to bimanual single finger alternating hand tapping (SFT), in PD. The variability of inter-strike interval (CVISI) and of amplitude (CVAMP) during AFT and SFT were measured on an engineered, MRI-compatible keyboard in sixteen PD subjects off medication and in twenty-four age-matched controls. The CVISI and CVAMP of the more affected (MA) and less affected (LA) sides in PD subjects were greater during AFT than SFT (P < 0.05). However, there was no difference between AFT and SFT for controls. Both CVISI and CVAMP were greater in the MA and LA hands of PD subjects versus controls during AFT (P < 0.01). The CVISI and CVAMP of the MA, but not the LA hand, were greater in PDs versus controls during SFT (P < 0.05). Also, AFT, but not SFT, detected a difference between the MA and LA hands of PDs (P < 0.01). Unimanual, repetitive alternating finger tapping brings out more arrhythmokinesis compared to bimanual, single finger tapping in PDs but not in controls. Arrhythmokinesis during unimanual, alternating finger tapping captured a significant difference between both the MA and LA hands of PD subjects and controls, whereas that during a bimanual, single finger tapping task only distinguished between the MA hand and controls. Arrhythmokinesis underlies freezing of gait and may also underlie the freezing behavior documented in fine motor control if studied using a unimanual alternating finger tapping task.

  12. Comparing kinematic changes between a finger-tapping task and unconstrained finger flexion-extension task in patients with Parkinson's disease.

    PubMed

    Teo, W P; Rodrigues, J P; Mastaglia, F L; Thickbroom, G W

    2013-06-01

    Repetitive finger tapping is a well-established clinical test for the evaluation of parkinsonian bradykinesia, but few studies have investigated other finger movement modalities. We compared the kinematic changes (movement rate and amplitude) and response to levodopa during a conventional index finger-thumb-tapping task and an unconstrained index finger flexion-extension task performed at maximal voluntary rate (MVR) for 20 s in 11 individuals with levodopa-responsive Parkinson's disease (OFF and ON) and 10 healthy age-matched controls. Between-task comparisons showed that for all conditions, the initial movement rate was greater for the unconstrained flexion-extension task than the tapping task. Movement rate in the OFF state was slower than in controls for both tasks and normalized in the ON state. The movement amplitude was also reduced for both tasks in OFF and increased in the ON state but did not reach control levels. The rate and amplitude of movement declined significantly for both tasks under all conditions (OFF/ON and controls). The time course of rate decline was comparable for both tasks and was similar in OFF/ON and controls, whereas the tapping task was associated with a greater decline in MA, both in controls and ON, but not OFF. The findings indicate that both finger movement tasks show similar kinematic changes during a 20-s sustained MVR, but that movement amplitude is less well sustained during the tapping task than the unconstrained finger movement task. Both movement rate and amplitude improved with levodopa; however, movement rate was more levodopa responsive than amplitude.

  13. Finger tapping analysis in patients with Parkinson's disease and atypical parkinsonism.

    PubMed

    Djurić-Jovičić, Milica; Petrović, Igor; Ječmenica-Lukić, Milica; Radovanović, Saša; Dragašević-Mišković, Nataša; Belić, Minja; Miler-Jerković, Vera; Popović, Mirjana B; Kostić, Vladimir S

    2016-08-01

    The goal of this study was to investigate repetitive finger tapping patterns in patients with Parkinson's disease (PD), progressive supranuclear palsy-Richardson syndrome (PSP-R), or multiple system atrophy of parkinsonian type (MSA-P). The finger tapping performance was objectively assessed in PD (n=13), PSP-R (n=15), and MSA-P (n=14) patients and matched healthy controls (HC; n=14), using miniature inertial sensors positioned on the thumb and index finger, providing spatio-temporal kinematic parameters. The main finding was the lack or only minimal progressive reduction in amplitude during the finger tapping in PSP-R patients, similar to HC, but significantly different from the sequence effect (progressive decrement) in both PD and MSA-P patients. The mean negative amplitude slope of -0.12°/cycle revealed less progression of amplitude decrement even in comparison to HC (-0.21°/cycle, p=0.032), and particularly from PD (-0.56°/cycle, p=0.001), and MSA-P patients (-1.48°/cycle, p=0.003). No significant differences were found in the average finger separation amplitudes between PD, PSP-R and MSA-P patients (pmsa-pd=0.726, pmsa-psp=0.363, ppsp-pd=0.726). The lack of clinically significant sequence effect during finger tapping differentiated PSP-R from both PD and MSA-P patients, and might be specific for PSP-R. The finger tapping kinematic parameter of amplitude slope may be a neurophysiological marker able to differentiate particular forms of parkinsonism. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Fingers' vibration transmission and grip strength preservation performance of vibration reducing gloves.

    PubMed

    Hamouda, K; Rakheja, S; Dewangan, K N; Marcotte, P

    2018-01-01

    The vibration isolation performances of vibration reducing (VR) gloves are invariably assessed in terms of power tools' handle vibration transmission to the palm of the hand using the method described in ISO 10819 (2013), while the nature of vibration transmitted to the fingers is ignored. Moreover, the VR gloves with relatively low stiffness viscoelastic materials affect the grip strength in an adverse manner. This study is aimed at performance assessments of 12 different VR gloves on the basis of handle vibration transmission to the palm and the fingers of the gloved hand, together with reduction in the grip strength. The gloves included 3 different air bladder, 3 gel, 3 hybrid, and 2 gel-foam gloves in addition to a leather glove. Two Velcro finger adapters, each instrumented with a three-axis accelerometer, were used to measure vibration responses of the index and middle fingers near the mid-phalanges. Vibration transmitted to the palm was measured using the standardized palm adapter. The vibration transmissibility responses of the VR gloves were measured in the laboratory using the instrumented cylindrical handle, also described in the standard, mounted on a vibration exciter. A total of 12 healthy male subjects participated in the study. The instrumented handle was also used to measure grip strength of the subjects with and without the VR gloves. The results of the study showed that the VR gloves, with only a few exceptions, attenuate handle vibration transmitted to the fingers only in the 10-200 Hz and amplify middle finger vibration at frequencies exceeding 200 Hz. Many of the gloves, however, provided considerable reduction in vibration transmitted to the palm, especially at higher frequencies. These suggest that the characteristics of vibration transmitted to fingers differ considerably from those at the palm. Four of the test gloves satisfied the screening criteria of the ISO 10819 (2013) based on the palm vibration alone, even though these caused amplification of handle vibration at the fingers. The fingers' vibration transmission performance of gloves were further evaluated using a proposed finger frequency-weighting W f apart from the standardized W h -weighting. It is shown that the W h weighting generally overestimates the VR glove effectiveness in limiting the fingers vibration in the high (H: 200-1250 Hz) frequency range. Both the weightings, however, revealed comparable performance of gloves in the mid (M: 25-200 Hz) frequency range. The VR gloves, with the exception of the leather glove, showed considerable reductions in the grip strength (27-41%), while the grip strength reduction was not correlated with the glove material thickness. It is suggested that effectiveness of VR gloves should be assessed considering the vibration transmission to both the palm and fingers of the hand together with the hand grip strength reduction. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. 21 CFR 888.3210 - Finger joint metal/metal constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Finger joint metal/metal constrained cemented prosthesis. 888.3210 Section 888.3210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3210 Finger joint...

  16. 21 CFR 888.3210 - Finger joint metal/metal constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Finger joint metal/metal constrained cemented prosthesis. 888.3210 Section 888.3210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3210 Finger joint...

  17. 21 CFR 888.3200 - Finger joint metal/metal constrained uncemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Finger joint metal/metal constrained uncemented prosthesis. 888.3200 Section 888.3200 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3200 Finger joint...

  18. 21 CFR 888.3210 - Finger joint metal/metal constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Finger joint metal/metal constrained cemented prosthesis. 888.3210 Section 888.3210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3210 Finger joint...

  19. 21 CFR 888.3200 - Finger joint metal/metal constrained uncemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Finger joint metal/metal constrained uncemented prosthesis. 888.3200 Section 888.3200 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3200 Finger joint...

  20. 21 CFR 888.3200 - Finger joint metal/metal constrained uncemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Finger joint metal/metal constrained uncemented prosthesis. 888.3200 Section 888.3200 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3200 Finger joint...

  1. Response Preparation with Static versus Moving Hands

    ERIC Educational Resources Information Center

    Adam, Jos J.; Moresi, Sofie

    2007-01-01

    This research tested the response inhibition account of the hand-advantage found in the finger precuing task. According to this account, the advantage of preparing two fingers on one hand (represented in one hemisphere) as opposed to preparing two fingers on two hands (represented in two hemispheres) is due, in part, to a response inhibition…

  2. Reliability and Validity of Finger Strength and Endurance Measurements in Rock Climbing

    ERIC Educational Resources Information Center

    Michailov, Michail Lubomirov; Baláš, Jirí; Tanev, Stoyan Kolev; Andonov, Hristo Stoyanov; Kodejška, Jan; Brown, Lee

    2018-01-01

    Purpose: An advanced system for the assessment of climbing-specific performance was developed and used to: (a) investigate the effect of arm fixation (AF) on construct validity evidence and reliability of climbing-specific finger-strength measurement; (b) assess reliability of finger-strength and endurance measurements; and (c) evaluate the…

  3. Cortex Inspired Model for Inverse Kinematics Computation for a Humanoid Robotic Finger

    PubMed Central

    Gentili, Rodolphe J.; Oh, Hyuk; Molina, Javier; Reggia, James A.; Contreras-Vidal, José L.

    2013-01-01

    In order to approach human hand performance levels, artificial anthropomorphic hands/fingers have increasingly incorporated human biomechanical features. However, the performance of finger reaching movements to visual targets involving the complex kinematics of multi-jointed, anthropomorphic actuators is a difficult problem. This is because the relationship between sensory and motor coordinates is highly nonlinear, and also often includes mechanical coupling of the two last joints. Recently, we developed a cortical model that learns the inverse kinematics of a simulated anthropomorphic finger. Here, we expand this previous work by assessing if this cortical model is able to learn the inverse kinematics for an actual anthropomorphic humanoid finger having its two last joints coupled and controlled by pneumatic muscles. The findings revealed that single 3D reaching movements, as well as more complex patterns of motion of the humanoid finger, were accurately and robustly performed by this cortical model while producing kinematics comparable to those of humans. This work contributes to the development of a bioinspired controller providing adaptive, robust and flexible control of dexterous robotic and prosthetic hands. PMID:23366569

  4. Investigation of methods for estimating hand bone dimensions using X-ray hand anthropometric data.

    PubMed

    Kong, Yong-Ku; Freivalds, Andris; Kim, Dae-Min; Chang, Joonho

    2017-06-01

    This study examined two conversion methods, M1 and M2, to predict finger/phalange bone lengths based on finger/phalange surface lengths. Forty-one Korean college students (25 males and 16 females) were recruited and their finger/phalange surface lengths, bone lengths and grip strengths were measured using a vernier caliper, an X-ray generator and a double-handle force measurement system, respectively. M1 and M2 were defined as formulas able to estimate finger/phalange bone lengths based on one dimension (i.e., surface hand length) and four finger dimensions (surface finger lengths), respectively. As a result of conversion, the estimation errors by M1 presented mean 1.22 mm, which was smaller than those (1.29 mm) by M2. The bone lengths estimated by M1 (mean r = 0.81) presented higher correlations with the measured bone lengths than those estimated by M2 (0.79). Thus, the M1 method was recommended in the present study, based on conversion simplicity and accuracy.

  5. Viscous Fingering on an Immiscible Reactive Interface with Variation of Interfacial Tension

    NASA Astrophysics Data System (ADS)

    Tsuzuki, Reiko; Nagatsu, Yuichiro; Li, Qian; Chen, Ching-Yao

    2017-11-01

    The effects of chemical reaction, in which surfactants are produced on the interface of two immiscible fluids, on viscous fingering in a radial Hele-Shaw flow are numerically investigated. The presence of surfactants reduces interfacial tension, which is an important factor to the fingering pattern formation. In the present study, influences of reaction rate and dispersion of produced surfactants, represented respectively by dimensionless parameters of Damkohler number and Peclet number, are evaluated systematically. Secondary fingering instability, e.g., tip-splitting and side-branching, is triggered by chemical reactions. Weaker surface tension generally induces tip-splitting. For the case of high Damkohler number, because of the vortex pairs generated within each finger, surfactant tends to accumulate significantly on the side of finger, so that side-branching is preferred. Nevertheless, side-branching is suppressed in the cases associated with low Peclet number, in which strong dispersion reduces the local variation of surfactant concentration. Considering the coupled effects by Damkohler number and Peclet number, the patterns obtained by the simulations qualitatively agree with the observations in the experiments.

  6. A Method for Recognizing State of Finger Flexure and Extension

    NASA Astrophysics Data System (ADS)

    Terado, Toshihiko; Fujiwara, Osamu

    In our country, the handicapped and the elderly people in bed increase rapidly. In the bedridden person’s daily life, there may be limitations in the physical movement and the means of mutual communication. For the support of their comfortable daily lives, therefore, the development of human interface equipment becomes an important task. The equipment of this kind is being already developed by means of laser beam, eye-tracking, breathing motion and myo-electric signals, while the attachment and handling are normally not so easy. In this study, paying attention to finger motion, we have developed human interface equipment easily attached to the body, which enables one to measure the finger flexure and extension for mutual communication. The state of finger flexure and extension is identified by a threshold level analysis from the 3D-locus data for the finger movement, which can be measured through the infrared rays from the LED markers attached to a glove with the previously developed prototype system. We then have confirmed from an experiment that nearly 100% recognition for the finger movement can be achieved.

  7. Decreased bilateral cortical representation patterns in writer's cramp: a functional magnetic resonance imaging study at 3.0 T.

    PubMed

    Islam, Tina; Kupsch, Andreas; Bruhn, Harald; Scheurig, Christian; Schmidt, Sein; Hoffmann, Karl-Titus

    2009-06-01

    Functional magnetic resonance imaging was used to characterize patterns of cortical activation in response to sensory and motor tasks in patients with writer's cramp. 17 patients and 17 healthy subjects were examined during finger-tapping, index finger flexion, and electrical median nerve stimulation of both hands during electromyographic monitoring. SPM2 was used to evaluate Brodmann area (BA) 4, 1, 2, 3, 6, 40. Patients showed decreased activation in the left BA 4 with motor tasks of both hands and the left BA 1-3 with right finger-tapping. With left finger-tapping there was bilateral underactivation of single areas of the somatosensory cortex. Patients exhibited decreased activation in the bilateral BA 6 with left motor tasks and in the right BA 6 with right finger-tapping. Patients had decreased activation in bilateral BA 40 with finger-tapping of both hands. The findings suggest decreased baseline activity or an impaired activation in response to motor tasks in BA 1-4, 6, 40 in patients with writer's cramp for the dystonic and the clinically unaffected hand.

  8. Finger millet (Eleusine coracana) - an economically viable source for antihypercholesterolemic metabolites production by Monascus purpureus.

    PubMed

    Venkateswaran, V; Vijayalakshmi, G

    2010-08-01

    Rice, parboiled rice, finger millet, germinated finger millet, broken wheat, njavara (medicinal rice), sorghum and maize were used as substrates for solid state fermentation of Monascus purpureus at 28°C for 7 days using 2% seed medium as inoculum for the production of its metabolites. The fungus exhibited good growth in all the substrates. The fermented substrates were dried at 45°C and analysed for antihypercholesterolemic metabolite statins by standardized HPLC method and dietary sterol contents by spectrophotometric method using reference standards of statin (pravastatin and lovastatin) and cholesterol, respectively. Germinated finger millet yielded higher total statin production of 5.2 g/kg dry wt with pravastatin and lovastatin content of 4.9 and 0.37 g/kg dry wt respectively than other substrates which range from 1.04-4.41 g/kg. In addition to statin, monascus fermented germinated finger millet yielded dietary sterol of 0.053 g/kg dry wt which is 7.6 folds higher than the control. The value addition of finger millet by germination and fermentation with Monascus purpureus provides scope for development of functional food.

  9. Vertical Finger Displacement Is Reduced in Index Finger Tapping During Repeated Bout Rate Enhancement.

    PubMed

    Mora-Jensen, Mark Holten; Madeleine, Pascal; Hansen, Ernst Albin

    2017-10-01

    The present study analyzed (a) whether a recently reported phenomenon of repeated bout rate enhancement in finger tapping (i.e., a cumulating increase in freely chosen finger tapping frequency following submaximal muscle activation in the form of externally unloaded voluntary tapping) could be replicated and (b) the hypotheses that the faster tapping was accompanied by changed vertical displacement of the fingertip and changed peak force during tapping. Right-handed, healthy, and recreationally active individuals (n = 24) performed two 3-min index finger tapping bouts at freely chosen tapping frequency, separated by 10-min rest. The recently reported phenomenon of repeated bout rate enhancement was replicated. The faster tapping (8.8 ± 18.7 taps/min, corresponding to 6.0 ± 11.0%, p = .033) was accompanied by reduced vertical displacement (1.6 ± 2.9 mm, corresponding to 6.3 ± 14.9%, p = .012) of the fingertip. Concurrently, peak force was unchanged. The present study points at separate control mechanisms governing kinematics and kinetics during finger tapping.

  10. An improved finger-vein recognition algorithm based on template matching

    NASA Astrophysics Data System (ADS)

    Liu, Yueyue; Di, Si; Jin, Jian; Huang, Daoping

    2016-10-01

    Finger-vein recognition has became the most popular biometric identify methods. The investigation on the recognition algorithms always is the key point in this field. So far, there are many applicable algorithms have been developed. However, there are still some problems in practice, such as the variance of the finger position which may lead to the image distortion and shifting; during the identification process, some matching parameters determined according to experience may also reduce the adaptability of algorithm. Focus on above mentioned problems, this paper proposes an improved finger-vein recognition algorithm based on template matching. In order to enhance the robustness of the algorithm for the image distortion, the least squares error method is adopted to correct the oblique finger. During the feature extraction, local adaptive threshold method is adopted. As regard as the matching scores, we optimized the translation preferences as well as matching distance between the input images and register images on the basis of Naoto Miura algorithm. Experimental results indicate that the proposed method can improve the robustness effectively under the finger shifting and rotation conditions.

  11. Finger vein recognition based on personalized weight maps.

    PubMed

    Yang, Gongping; Xiao, Rongyang; Yin, Yilong; Yang, Lu

    2013-09-10

    Finger vein recognition is a promising biometric recognition technology, which verifies identities via the vein patterns in the fingers. Binary pattern based methods were thoroughly studied in order to cope with the difficulties of extracting the blood vessel network. However, current binary pattern based finger vein matching methods treat every bit of feature codes derived from different image of various individuals as equally important and assign the same weight value to them. In this paper, we propose a finger vein recognition method based on personalized weight maps (PWMs). The different bits have different weight values according to their stabilities in a certain number of training samples from an individual. Firstly we present the concept of PWM, and then propose the finger vein recognition framework, which mainly consists of preprocessing, feature extraction, and matching. Finally, we design extensive experiments to evaluate the effectiveness of our proposal. Experimental results show that PWM achieves not only better performance, but also high robustness and reliability. In addition, PWM can be used as a general framework for binary pattern based recognition.

  12. Finger Vein Recognition Based on Personalized Weight Maps

    PubMed Central

    Yang, Gongping; Xiao, Rongyang; Yin, Yilong; Yang, Lu

    2013-01-01

    Finger vein recognition is a promising biometric recognition technology, which verifies identities via the vein patterns in the fingers. Binary pattern based methods were thoroughly studied in order to cope with the difficulties of extracting the blood vessel network. However, current binary pattern based finger vein matching methods treat every bit of feature codes derived from different image of various individuals as equally important and assign the same weight value to them. In this paper, we propose a finger vein recognition method based on personalized weight maps (PWMs). The different bits have different weight values according to their stabilities in a certain number of training samples from an individual. Firstly we present the concept of PWM, and then propose the finger vein recognition framework, which mainly consists of preprocessing, feature extraction, and matching. Finally, we design extensive experiments to evaluate the effectiveness of our proposal. Experimental results show that PWM achieves not only better performance, but also high robustness and reliability. In addition, PWM can be used as a general framework for binary pattern based recognition. PMID:24025556

  13. Steam trap monitor

    DOEpatents

    Ryan, M.J.

    1987-05-04

    A steam trap monitor positioned downstream of a steam trap in a closed steam system includes a first sensor (a hot finger) for measuring the energy of condensate and a second sensor (a cold finger) for measuring the total energy of condensate and steam in the line. The hot finger includes one or more thermocouples for detecting condensate level and energy, while the cold finger contains a liquid with a lower boiling temperature than that of water. Vapor pressure from the liquid is used to do work such as displacing a piston or bellow in providing an indication of total energy (steam + condensate) of the system. Processing means coupled to and responsive to outputs from the hot and cold fingers subtracts the former from the latter to provide an indication of the presence of steam downstream from the trap indicating that the steam trap is malfunctioning. 2 figs.

  14. Granular fingering as a mechanism for ridge formation in debris avalanche deposits: Laboratory experiments and implications for Tutupaca volcano, Peru

    NASA Astrophysics Data System (ADS)

    Valderrama, P.; Roche, O.; Samaniego, P.; van Wyk des Vries, B.; Araujo, G.

    2018-01-01

    The origin of subparallel, regularly-spaced longitudinal ridges often observed at the surface of volcanic and other rock avalanche deposits remains unclear. We addressed this issue through analogue laboratory experiments on flows of bi-disperse granular mixtures, because this type of flow is known to exhibit granular fingering that causes elongated structures resembling the ridges observed in nature. We considered four different mixtures of fine (300-400 μm) glass beads and coarse (600-710 μm to 900-1000 μm) angular crushed fruit stones, with particle size ratios of 1.9-2.7 and mass fractions of the coarse component of 5-50 wt%. The coarse particles segregated at the flow surface and accumulated at the front where flow instabilities with a well-defined wavelength grew. These formed granular fingers made of coarse-rich static margins delimiting fines-rich central channels. Coalescence of adjacent finger margins created regular spaced longitudinal ridges, which became topographic highs as finger channels drained at final emplacement stages. Three distinct deposit morphologies were observed: 1) Joined fingers with ridges were formed at low (≤ 1.9) size ratio and moderate (10-20 wt%) coarse fraction whereas 2) separate fingers or 3) poorly developed fingers, forming series of frontal lobes, were created at larger size ratios and/or higher coarse contents. Similar ridges and lobes are observed at the debris avalanche deposits of Tutupaca volcano, Peru, suggesting that the processes operating in the experiments can also occur in nature. This implies that volcanic (and non-volcanic) debris avalanches can behave as granular flows, which has important implications for interpretation of deposits and for modeling. Such behaviour may be acquired as the collapsing material disaggregates and forms a granular mixture composed by a right grain size distribution in which particle segregation can occur. Limited fragmentation and block sliding, or grain size distributions inappropriate for promoting granular fingering can explain why ridges are absent in many deposits.

  15. Pistol-grip Syringe holder (Cameco syringe pistol) in fine needle aspiration Biopsy: any advantages over the use of direct finger grip?

    PubMed

    Mayun, A A; Nggada, H A; Abdulazzez, J O; Musa, A B; Pindiga, U H; Khalil, M I

    2013-06-01

    The study seeks to determine the advantages of using the pistol-grip syringe holder in the performance of FNAB over the use of direct finger grip method. The skin is cleaned with gauze soaked in methylated spirit and the lump is located and firmly held between the thumb and fore finger of the free hand. The syringe is held by the out side of the barrel or by pistol-grip, and the needle tip pushed into the lesion. The plunger is partially retracted, creating a negative pressure. The cutting edge of the needle tip frees the cells inside the lesion which are sucked into the fine bore of the needle. The contents of the needle are then emptied on a microscopic slide and thinly smeared. The slides are then fixed in alcohol and later stained. These were examined under the microscope and a comparison between the aspirations using pistol-grip and direct finger grip was made. A total of 266 cases of FNABs were carried out from 1st January to 31st December, 2008. There were 89 breast cases out of which 42 (47%) had pistol-grip method and 47 (53%) had direct finger grip method; 74 thyroid cases out of which 28 (38%) were pistol-grip and 46 (62%) were direct finger grip cases; 56 cases of lymph node FNABs of which 18(32%) and 38 (68%) had pistol-grip and direct finger grip methods respectively. There were 23 cases of salivary gland FNABs having 8 (35%) and 15 (65%) as pistol-grip and direct finger grip methods respectively. Marked cellularity was observed in the majority of cases using both methods of FNABs. This study has shown that the use of pistol-grip syringe holder in the performance of FNABs has no significant advantage compared to the direct finger grip method.

  16. Finger doses for staff handling radiopharmaceuticals in nuclear medicine.

    PubMed

    Pant, Gauri S; Sharma, Sanjay K; Rath, Gaura K

    2006-09-01

    Radiation doses to the fingers of occupational workers handling 99mTc-labeled compounds and 131I for diagnostic and therapeutic procedures in nuclear medicine were measured by thermoluminescence dosimetry. The doses were measured at the base of the ring finger and the index finger of both hands in 2 groups of workers. Group 1 (7 workers) handled 99mTc-labeled radiopharmaceuticals, and group 2 (6 workers) handled 131I for diagnosis and therapy. Radiation doses to the fingertips of 3 workers also were measured. Two were from group 1, and 1 was from group 2. The doses to the base of the fingers for the radiopharmacy staff and physicians from group 1 were observed to be 17+/-7.5 (mean+/-SD) and 13.4+/-6.5 microSv/GBq, respectively. Similarly, the dose to the base of the fingers for the 3 physicians in group 2 was estimated to be 82.0+/-13.8 microSv/GBq. Finger doses for the technologists in both groups could not be calculated per unit of activity because they did not handle the radiopharmaceuticals directly. Their doses were reported in millisieverts that accumulated in 1 wk. The doses to the fingertips of the radiopharmacy worker and the physician in group 1 were 74.3+/-19.8 and 53.5+/-21.9 microSv/GBq, respectively. The dose to the fingertips of the physician in group 2 was 469.9+/-267 microSv/GBq. The radiation doses to the fingers of nuclear medicine staff at our center were measured. The maximum expected annual dose to the extremities appeared to be less than the annual limit (500 mSv/y), except for a physician who handled large quantities of 131I for treatment. Because all of these workers are on rotation and do not constantly handle radioactivity throughout the year, the doses to the base of the fingers or the fingertips should not exceed the prescribed annual limit of 500 mSv.

  17. Two-thumb technique is superior to two-finger technique during lone rescuer infant manikin CPR.

    PubMed

    Udassi, Sharda; Udassi, Jai P; Lamb, Melissa A; Theriaque, Douglas W; Shuster, Jonathan J; Zaritsky, Arno L; Haque, Ikram U

    2010-06-01

    Infant CPR guidelines recommend two-finger chest compression with a lone rescuer and two-thumb with two rescuers. Two-thumb provides better chest compression but is perceived to be associated with increased ventilation hands-off time. We hypothesized that lone rescuer two-thumb CPR is associated with increased ventilation cycle time, decreased ventilation quality and fewer chest compressions compared to two-finger CPR in an infant manikin model. Crossover observational study randomizing 34 healthcare providers to perform 2 min CPR at a compression rate of 100 min(-1) using a 30:2 compression:ventilation ratio comparing two-thumb vs. two-finger techniques. A Laerdal Baby ALS Trainer manikin was modified to digitally record compression rate, compression depth and compression pressure and ventilation cycle time (two mouth-to-mouth breaths). Manikin chest rise with breaths was video recorded and later reviewed by two blinded CPR instructors for percent effective breaths. Data (mean+/-SD) were analyzed using a two-tailed paired t-test. Significance was defined qualitatively as p< or =0.05. Mean % effective breaths were 90+/-18.6% in two-thumb and 88.9+/-21.1% in two-finger, p=0.65. Mean time (s) to deliver two mouth-to-mouth breaths was 7.6+/-1.6 in two-thumb and 7.0+/-1.5 in two-finger, p<0.0001. Mean delivered compressions per minute were 87+/-11 in two-thumb and 92+/-12 in two-finger, p=0.0005. Two-thumb resulted in significantly higher compression depth and compression pressure compared to the two-finger technique. Healthcare providers required 0.6s longer time to deliver two breaths during two-thumb lone rescuer infant CPR, but there was no significant difference in percent effective breaths delivered between the two techniques. Two-thumb CPR had 4 fewer delivered compressions per minute, which may be offset by far more effective compression depth and compression pressure compared to two-finger technique. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

  18. Radial Viscous Fingering and its Surface Expression due to Convective Upwelling Beneath North Atlantic Ocean

    NASA Astrophysics Data System (ADS)

    White, N. J.; Schoonman, C. M.

    2016-12-01

    The Icelandic mantle plume has had a significant influence on the geologic and oceanographic evolution of the North Atlantic Ocean during Cenozoic times. Full-waveform tomographic imaging of this region show that the planform of this plume has a complex irregular shape with significant shear wave velocity anomalies lying beneath the lithospheric plates between 100 and 200 km depth. The planform of these anomalies suggests that five or more horizontal fingers extend radially beneath the fringing continental margins. The best-imaged fingers lie beneath the British Isles and beneath western Norway where significant crustal isostatic departures have been measured. Here, we propose that these radial fingers are generated by a phenomenon known as the Saffman-Taylor instability. Experimental and theoretical analyses show that radial, miscible viscous fingering occurs when a less viscous fluid is injected into a more viscous fluid. The wavelength and number of fingers are controlled by the mobility (i.e. the ratio of viscosities), by the Peclet number (i.e. the ratio of advective and diffusive processes), and by the thickness of the horizontal layer into which fluid is injected. We have combined shear wave velocity estimates with residual depth measurements around the Atlantic margins to calculate the planform distribution of temperature and viscosity within an asthenospheric layer beneath the lithospheric plates. Our calculations suggest that the mobility is 20-50, that the Peclet number is O(104, and that the asthenospheric channel is 150 ± 50 km thick. The existence and form of viscous fingering is consistent with experimental observations and with linear stability analysis. A useful rule of thumb is that the wavelength of viscous fingering is 5 ± 1 times the thickness of the horizontal layer. Our proposal support the notion that dynamic topography of the Earth's surface can be influenced by rapid horizontal flow within spatially evolving asthenospheric fingers.

  19. Radial, Viscous, Saffman-Taylor Fingering of Hot Asthenosphere associated with the Icelandic plume beneath the North Atlantic Ocean

    NASA Astrophysics Data System (ADS)

    White, Nicky; Schoonman, Charlotte

    2017-04-01

    The Icelandic plume has had a significant influence upon the geologic and oceanographic evolution of the North Atlantic Ocean throughout Cenozoic times. Published full-waveform earthquake tomographic imaging of this region shows that the planform of this plume has a complex irregular shape with significant shear wave velocity anomalies lying beneath the lithospheric plate at depths of between 100 and 200 km. The planform of these anomalies suggests that five or more horizontal fingers extend radially beneath the fringing continental margins. The best-resolved of these fingers lie beneath the British Isles and beneath western Norway where significant crustal isostatic departures have been measured. Here, we propose that these radial fingers are generated by a well-known fluid dynamical phenomenon known as the Saffman-Taylor instability. Experimental and theoretical analyses show that radial, miscible viscous fingering occurs when a less viscous fluid is injected into a more viscous fluid. The wavelength and number of fingers are controlled by the mobility (i.e. the ratio of viscosities), by the Peclet number (i.e. the ratio of advective and diffusive processes), and by the thickness of the horizontal layer into which fluid is injected. We have combined shear wave velocity estimates with residual depth measurements around the Atlantic margins to calculate the planform distribution of temperature and viscosity within an asthenospheric layer beneath the lithospheric plates. Our calculations suggest that the mobility is 20-50, that the Peclet number is O(10000), and that the asthenospheric channel is 150 +/- 50 km thick. The existence and form of viscous fingering is consistent with experimental observations and with linear stability analysis. A useful rule of thumb is that the wavelength of viscous fingering is 5 +/- 1 times the thickness of the horizontal layer. Our proposal support the notion that dynamic topography of the Earth's surface can be generated and maintained by rapid horizontal flow within spatially evolving asthenospheric fingers.

  20. Energy harvesting from mouse click of robot finger using piezoelectrics

    NASA Astrophysics Data System (ADS)

    Cha, Youngsu; Hong, Jin; Lee, Jaemin; Park, Jung-Min; Kim, Keehoon

    2017-04-01

    In this paper, we investigate the feasibility of energy harvesting from the mouse click motion using a piezoelectric energy transducer. Specifically, we use a robotic finger to realize repeatable mouse click motion. The robotic finger wears a glove with a pocket for including the piezoelectric material as an energy transducer. We propose a model for the energy harvesting system through the inverse kinematic framework of parallel joints in the finger and the electromechanical coupling equations of the piezoelectric material. Experiments are performed to elucidate the effect of the load resistance and the mouse click motion on energy harvesting.

  1. Toe-to-hand transfer.

    PubMed

    Yoshimura, M

    1980-07-01

    Toe-to-hand transfer was performed in 28 patients, involving 33 fingers, using microvascular technique. Of this number, 26 patients (31 fingers) had experienced trauma, and the remaining 2 patients (2 fingers) had a congenital deformity. The toew used for grafting were the great toe (1), the second tow (30), and third toe (2). Success was achieved in all cases, sensory recovery was good, and remarkable improvement was attained in function and cosmetic appearance. Metacarpal hand, amputation of thumb, and amputation thumb and three fingers were good indications for this procedure, which gave satisfactory aesthetic results, even in patients with amputation of single digits.

  2. Finger rafting: a generic instability of floating elastic sheets.

    PubMed

    Vella, Dominic; Wettlaufer, J S

    2007-02-23

    Colliding ice floes are often observed to form a series of interlocking fingers. We show that this striking phenomenon is not a result of some peculiar property of ice but rather a general and robust mechanical phenomenon reproducible in the laboratory with other floating materials. We determine the theoretical relationship between the width of the resulting fingers and the material's mechanical properties and present experimental results along with field observations to support the theory. The generality of this "finger rafting" suggests that analogous processes may be responsible for creating the large-scale structures observed at the boundaries between Earth's convergent tectonic plates.

  3. Comparison of the Structure and Expression of Odd-Skipped and Two Related Genes That Encode a New Family of Zinc Finger Proteins in Drosophila

    PubMed Central

    Hart, M. C.; Wang, L.; Coulter, D. E.

    1996-01-01

    The odd-skipped (odd) gene, which was identified on the basis of a pair-rule segmentation phenotype in mutant embryos, is initially expressed in the Drosophila embryo in seven pair-rule stripes, but later exhibits a segment polarity-like pattern for which no phenotypic correlate is apparent. We have molecularly characterized two embryonically expressed odd-cognate genes, sob and bowel (bowl), that encode proteins with highly conserved C(2)H(2) zinc fingers. While the Sob and Bowl proteins each contain five tandem fingers, the Odd protein lacks a fifth (C-terminal) finger and is also less conserved among the four common fingers. Reminiscent of many segmentation gene paralogues, the closely linked odd and sob genes are expressed during embryogenesis in similar striped patterns; in contrast, the less-tightly linked bowl gene is expressed in a distinctly different pattern at the termini of the early embryo. Although our results indicate that odd and sob are more likely than bowl to share overlapping developmental roles, some functional divergence between the Odd and Sob proteins is suggested by the absence of homology outside the zinc fingers, and also by amino acid substitutions in the Odd zinc fingers at positions that appear to be constrained in Sob and Bowl. PMID:8878683

  4. Finger vein identification using fuzzy-based k-nearest centroid neighbor classifier

    NASA Astrophysics Data System (ADS)

    Rosdi, Bakhtiar Affendi; Jaafar, Haryati; Ramli, Dzati Athiar

    2015-02-01

    In this paper, a new approach for personal identification using finger vein image is presented. Finger vein is an emerging type of biometrics that attracts attention of researchers in biometrics area. As compared to other biometric traits such as face, fingerprint and iris, finger vein is more secured and hard to counterfeit since the features are inside the human body. So far, most of the researchers focus on how to extract robust features from the captured vein images. Not much research was conducted on the classification of the extracted features. In this paper, a new classifier called fuzzy-based k-nearest centroid neighbor (FkNCN) is applied to classify the finger vein image. The proposed FkNCN employs a surrounding rule to obtain the k-nearest centroid neighbors based on the spatial distributions of the training images and their distance to the test image. Then, the fuzzy membership function is utilized to assign the test image to the class which is frequently represented by the k-nearest centroid neighbors. Experimental evaluation using our own database which was collected from 492 fingers shows that the proposed FkNCN has better performance than the k-nearest neighbor, k-nearest-centroid neighbor and fuzzy-based-k-nearest neighbor classifiers. This shows that the proposed classifier is able to identify the finger vein image effectively.

  5. Identification of the "A" genome of finger millet using chloroplast DNA.

    PubMed

    Hilu, K W

    1988-01-01

    Finger millet (Eleusine corocana subsp. coracana), an important cereal in East Africa and India, is a tetraploid species with unknown genomic components. A recent cytogenetic study confirmed the direct origin of this millet from the tetraploid E. coracana subsp. africana but questioned Eleusine indica as a genomic donor. Chloroplast (ct) DNA sequence analysis using restriction fragment pattern was used to examine the phylogenetic relationships between E. coracana subsp. coracana (domesticated finger millet), E. coracana subspecies africana (wild finger millet), and E. indica. Eleusine tristachya was included since it is the only other annual diploid species in the genus with a basic chromosome number of x = 9 like finger millet. Eight of the ten restriction endonucleases used had 16 to over 30 restriction sites per genome and were informative. E. coracana subsp. coracana and subsp. africana and E. indica were identical in all the restriction sites surveyed, while the ct genome of E, tristachya differed consistently by at least one mutational event for each restriction enzyme surveyed. This random survey of the ct genomes of these species points out E. indica as one of the genome donors (maternal genome donor) of domesticated finger millet contrary to a previous cytogenetic study. The data also substantiate E. coracana subsp. africana as the progenitor of domesticated finger millet. The disparity between the cytogenetic and the molecular approaches is discussed in light of the problems associated with chromosome pairing and polyploidy.

  6. Ribosomal DNA variation in finger millet and wild species of Eleusine (Poaceae).

    PubMed

    Hilu, K W; Johnson, J L

    1992-04-01

    Finger millet is an important cereal crop in the semi-arid regions of Africa and India. The crop belongs to the grass genus Eleusine, which includes nine annual and perennial species native to Africa except for the New World species E. tristachya. Ribosomal DNA (rDNA) variation in finger millet and related wild species was used to provide information on the origin of the genomes of this tetraploid crop and point out genetic relationships of the crop to other species in the genus. The restriction endonucleases used revealed a lack of variability in the rDNA spacer region in domesticated finger millet. All the rDNA variants of the crop were found in the proposed direct tetraploid ancestor, E. coracana subsp. africana. Wild and domesticated finger millet displayed the phenotypes found in diploid E. indica. Diploid Eleusine tristachya showed some similarity to the crop in some restriction sites. The remaining species were quite distinct in rDNA fragment patterns. The study supports the direct origin of finger millet from subspecies africana shows E. indica to be one of the genome donors of the crop, and demonstrates that none of the other species examined could have donated the second genome of the crop. The rDNA data raise the possibility that wild and domesticated finger millet could have originated as infraspecific polyploid hybrids from different varieties of E. indica.

  7. OUTFLOWS FROM EVOLVED STARS: THE RAPIDLY CHANGING FINGERS OF CRL 618

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Balick, Bruce; Huarte-Espinosa, Martin; Frank, Adam

    2013-07-20

    Our ultimate goal is to probe the nature of the collimator of the outflows in the pre-planetary nebula CRL 618. CRL 618 is uniquely suited for this purpose owing to its multiple, bright, and carefully studied finger-shaped outflows east and west of its nucleus. We compare new Hubble Space Telescope images to images in the same filters observed as much as 11 yr ago to uncover large proper motions and surface brightness changes in its multiple finger-shaped outflows. The expansion age of the ensemble of fingers is close to 100 yr. We find strong brightness variations at the fingertips duringmore » the past decade. Deep IR images reveal a multiple ring-like structure of the surrounding medium into which the outflows propagate and interact. Tightly constrained three-dimensional hydrodynamic models link the properties of the fingers to their possible formation histories. We incorporate previously published complementary information to discern whether each of the fingers of CRL 618 are the results of steady, collimated outflows or a brief ejection event that launched a set of bullets about a century ago. Finally, we argue on various physical grounds that fingers of CRL 618 are likely to be the result of a spray of clumps ejected at the nucleus of CRL 618 since any mechanism that form a sustained set of unaligned jets is unprecedented.« less

  8. Arthrodesis of the thumb interphalangeal joint and finger distal interphalangeal joints with a headless compression screw.

    PubMed

    Cox, Christopher; Earp, Brandon E; Floyd, W Emerson; Blazar, Philip E

    2014-01-01

    To study the results of using a small, headless compression screw (AcuTwist) for thumb interphalangeal (IP) joint and finger distal interphalangeal (DIP) joint arthrodeses. Between November 2007 and January 2012, 48 primary arthrodeses of the thumb IP joint or DIP joint in the other digits were performed in 29 consecutive patients with AcuTwist devices. Indications for arthrodesis included 19 cases of osteoarthritis in 25 fingers, 3 cases of lupus in 9 fingers, 2 cases of post-traumatic osteoarthritis in 2 fingers, and 1 case and finger each of acute trauma, neuromuscular disorder, postinfectious osteoarthritis, boutonniere deformity, and Dupuytren contracture. Charts were reviewed for clinical data, and radiographs were assessed for alignment and healing. Age averaged 59 years and follow-up averaged 12 months (range, 2-50 mo). Union occurred in 43 out of 46 fingers (94%). There were no cases of nail deformity, wound complications, tip hypersensitivity, or clinically notable malalignment. Three arthrodeses failed to fuse, including 2 asymptomatic nonunions and 1 fixation loss requiring revision with autograft. The complication rate was 9%. Distal digital joint arthrodesis with the AcuTwist resulted in a fusion rate of 94% with a complication rate of 9%. Our rate of fusion compares favorably with prior series using other methods of fixation. Therapeutic IV. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  9. White fingers, cold environment, and vibration--exposure among Swedish construction workers.

    PubMed

    Burström, Lage; Järvholm, Bengt; Nilsson, Tohr; Wahlström, Jens

    2010-11-01

    The aim of this study was to examine the association between white fingers, cold environment, and exposure to hand-arm vibration (HAV). The hypothesis was that working in cold climate increases the risk of white fingers. The occurrence of white fingers was investigated as a cross-sectional study in a cohort of Swedish male construction workers (N=134 757). Exposure to HAV was based on a job-exposure matrix. Living in the north or south of Sweden was, in a subgroup of the cohort, used as an indicator of the exposure to cold environment (ie, living in the north meant a higher exposure to cold climate). The analyses were adjusted for age and use of nicotine products (smoking and snuff). HAV-exposed workers living in a colder climate had a higher risk for white fingers than those living in a warmer climate [odds ratio (OR) 1.71, 95% confidence interval (95% CI) 1.42-2.06]. As expected, we found that HAV-exposed workers had an increased risk compared to controls (OR 2.02, 95% CI 1.75-2.34). The risk for white fingers increased with increased level of exposure to HAV and also age. Cold environment increases the risk for white fingers in workers occupationally exposed to HAV. The results underscore the need to keep exposure to HAV at workplaces as low as possible especially in cold climate.

  10. Assessment of finger forces and wrist torques for functional grasp using new multichannel textile neuroprostheses.

    PubMed

    Lawrence, Marc; Gross, Gion-Pitschen; Lang, Martin; Kuhn, Andreas; Keller, Thierry; Morari, Manfred

    2008-08-01

    New multichannel textile neuroprotheses were developed, which comprise multiple sets of transcutaneous electrode arrays and connecting wires embroidered into a fabric layer. The electrode arrays were placed on the forearm above the extrinsic finger flexors and extensors. Activation regions for selective finger flexion and wrist extension were configured by switching a subset of the array elements between cathode, anode, and off states. We present a new isometric measurement system for the assessment of finger forces and wrist torques generated using the new neuroprostheses. Finger forces (from the middle phalanxes) were recorded using five load cells mounted on a "grasp handle" that can be arbitrarily positioned in space. The hand and the grasp handle were rigidly mounted to a 6-degree of freedom load cell, and the forces and torques about the wrist were recorded. A vacuum cushion was used to comfortably fixate the forearm. The position and orientation of the forearm, wrist, fingers, and handle were recorded using a new three-dimensional position measurement system (accuracy <+/-1 mm). The measurement system was integrated into the real-time multichannel transcutaneous electrode environment, which is able to control the spatiotemporal position of multiple activation regions. Using the combined system and textile neuroprosthesis, we were able to optimize the activation regions to produce selective finger and wrist articulation, enabling improved functional grasp.

  11. [One-stage toenail lengthening: a report of 9 cases].

    PubMed

    Zhang, Gong-Lin; Guo, Ao; Zhang, Ming; Xu, Zhao-Yao; Zhang, Ling-Zhi; Wang, Shun-Bing; Li, Jun; Wu, Fa-Lin; Yu, Hui

    2008-01-01

    To summarize clinical application of one-stage toenail lengthening in free second toe transfer for reconstruction of the thumb (finger). Nine patients (male 7, female 2) underwent thumb (finger) reconstruction with second toe transfer were treated by one-stage toenail lengthening technique. Eight were the thumb and 1 was the index finger. Patients aged from 18 to 46 years,with an average of 25 years. A rectangle skin was resected at 0.5 cm away from the eponychium, which was 0.2 cm high and as wide as the toenail. Then stripped U shape flap gently towards proximal end and sutured it. During the operation, the injury of the subcutaneous vascular network should be avoided. Superficial infection at donor area happened in 1 case and was healed by changing dressings. All the reconstruction thumbs (fingers) had survived completely. 2 to 3 mm extending of toenail length was obtained and the appearance of thumb (finger) was improved. There was no growth deformation of toenail. After 7 to 24 months follow up (the average time 13 months), the appearance of the nail was good. One-stage toenail lengthening in free second toe transfer for reconstruction of the thumb (finger), which can obtain a satisfactory appearance of the nail and have no influence on the motion of the reconstruction thumb (finger), is a simple and an effective operative procedure.

  12. Quick-connect fasteners for assembling devices in space

    NASA Technical Reports Server (NTRS)

    Wesselski, Clarence J. (Inventor); Evenson, Erik E. (Inventor); Ruiz, Steve L. (Inventor)

    1992-01-01

    A quick-connect fastener of a relatively-simple straightforward design is arranged with a tubular body adapted to be engaged against an attachment fitting in coincidental alignment with an opening in that fitting. A tubular collet having flexible finger projecting from its forward end is arranged in the fastener body to be shifted forwardly by an elongated expander member coaxially arranged within the tubular collet for advancing the collet fingers into the opening in the attachment fitting. Biasing means are arranged between the elongated expander member and a rotatable actuator which is threadedly mounted within the tubular collet so as to be rotated for urging the expander member into engagement with the collet fingers. A first coupling member is arranged on the rotatable actuator to be accessible from outside of the fastener so that a second coupling member on the distal end of a flexible shaft can be introduced into the fastener body and coupled to the first coupling member to enable a typical actuating tool coupled to the shaft outside of the fastener body to be operated for advancing the outwardly-enlarged ends of the collet fingers into the opening in the attachment fitting and thereafter rotating the actuator member to expand the fingers to that attachment fitting. Upon expansion of the collet fingers, the biasing means impose a biasing force on the expander to releasably retain the fingers in their latching positions.

  13. Reconstruction of gastric slow wave from finger photoplethysmographic signal using radial basis function neural network.

    PubMed

    Mohamed Yacin, S; Srinivasa Chakravarthy, V; Manivannan, M

    2011-11-01

    Extraction of extra-cardiac information from photoplethysmography (PPG) signal is a challenging research problem with significant clinical applications. In this study, radial basis function neural network (RBFNN) is used to reconstruct the gastric myoelectric activity (GMA) slow wave from finger PPG signal. Finger PPG and GMA (measured using Electrogastrogram, EGG) signals were acquired simultaneously at the sampling rate of 100 Hz from ten healthy subjects. Discrete wavelet transform (DWT) was used to extract slow wave (0-0.1953 Hz) component from the finger PPG signal; this slow wave PPG was used to reconstruct EGG. A RBFNN is trained on signals obtained from six subjects in both fasting and postprandial conditions. The trained network is tested on data obtained from the remaining four subjects. In the earlier study, we have shown the presence of GMA information in finger PPG signal using DWT and cross-correlation method. In this study, we explicitly reconstruct gastric slow wave from finger PPG signal by the proposed RBFNN-based method. It was found that the network-reconstructed slow wave provided significantly higher (P < 0.0001) correlation (≥ 0.9) with the subject's EGG slow wave than the correlation obtained (≈0.7) between the PPG slow wave from DWT and the EEG slow wave. Our results showed that a simple finger PPG signal can be used to reconstruct gastric slow wave using RBFNN method.

  14. Investigation of force, contact area, and dwell time in finger-tapping tasks on membrane touch interface.

    PubMed

    Liu, Na; Yu, Ruifeng

    2018-06-01

    This study aimed to determine the touch characteristics during tapping tasks on membrane touch interface and investigate the effects of posture and gender on touch characteristics variables. One hundred participants tapped digits displayed on a membrane touch interface on sitting and standing positions using all fingers of the dominant hand. Touch characteristics measures included average force, contact area, and dwell time. Across fingers and postures, males exerted larger force and contact area than females, but similar dwell time. Across genders and postures, thumb exerted the largest force and the force of the other four fingers showed no significant difference. The contact area of the thumb was the largest, whereas that of the little finger was the smallest; the dwell time of the thumb was the longest, whereas that of the middle finger was the shortest. Relationships among finger sizes, gender, posture and touch characteristics were proposed. The findings helped direct membrane touch interface design for digital and numerical control products from hardware and software perspectives. Practitioner Summary: This study measured force, contact area, and dwell time in tapping tasks on membrane touch interface and examined effects of gender and posture on force, contact area, and dwell time. The findings will direct membrane touch interface design for digital and numerical control products from hardware and software perspectives.

  15. Cancer risk among patients with finger and hand joint and temporo-mandibular joint prostheses in Denmark.

    PubMed

    Fryzek, J P; Mellemkjaer, L; McLaughlin, J K; Blot, W J; Olsen, J H

    1999-05-31

    The use of artificial joint implants has risen greatly over the past years. However, few investigations of the cancer risk associated with implants have been performed. We investigated cancer risk in patients with finger and hand joint and temporo-mandibular (TMJ) joint implants. A nationwide cohort in Denmark of patients with finger and hand joint prostheses (n = 858) or TMJ implants (n = 389) was followed from January 1, 1977, to December 31, 1995, to evaluate any potential cancer risks subsequent to receiving these implants. Standardized incidence ratios (SIRs) for all cancers were 1.0 (95% CI = 0.8-1.2) for the finger and hand joint cohort and 1.1 (95% CI = 0.8-1.7) for the TMJ cohort. A significant risk for non-Hodgkin's lymphoma was found in the finger and hand joint cohort (SIR = 3.8, 95% CI = 1.5-7.8). When the finger and hand joint cohort was stratified by diagnosis of rheumatoid arthritis, the excess risk was seen only in the group with rheumatoid arthritis. This is consistent with past studies, which have found an association between rheumatoid arthritis and non-Hodgkin's lymphoma. Our results provide evidence that the cancer risk for patients with finger and hand joint prostheses and TMJ implants is similar to that for the general population.

  16. Effects of pressure, cold and gloves on hand skin temperature and manual performance of divers.

    PubMed

    Zander, Joanna; Morrison, James

    2008-09-01

    Cold water immersion and protective gloves are associated with decreased manual performance. Although neoprene gloves slow hand cooling, there is little information on whether they provide sufficient protection when diving in cold water. Nine divers wearing three-fingered neoprene gloves and dry suits were immersed in water at 25 and 4 degrees C, at depths of 0.4 msw (101 kPa altitude adjusted) and 40 msw (497 kPa) in a hyperbaric chamber. Skin temperatures were measured at the fingers, hand, forearm, chest and head. Grip strength, tactile sensitivity and manual dexterity were measured at three time intervals. There was an exponential decay in finger and back of hand skin temperatures with exposure time in 4 degrees C water. Finger and back of hand skin temperatures were lower at 40 msw than at 0.4 msw (P < 0.05). There was no effect of pressure or temperature on grip strength. Tactile sensitivity decreased linearly with finger skin temperature at both pressures. Manual dexterity was not affected by finger skin temperature at 0.4 msw, but decreased with fall in finger skin temperature at 40 msw. Results show that neoprene gloves do not provide adequate thermal protection in 4 degrees C water and that impairment of manual performance is dependent on the type of task, depth and exposure time.

  17. Ergonomics: The Study of Work

    DTIC Science & Technology

    2000-01-01

    Disease Name thumbs pain at the base of the thumbs twisting and gripping butchers , house- keepers, packers, seam- stresses, cutters fingers De...Quervain’s disease difficulty moving finger; snapping and jerking movements repeatedly using the index fingers meatpackers, poultry workers, carpenters...line workers rotator cuff tendinitis hands, wrists pain, swelling repetitive or forceful hand and wrist motions core making, poultry process- ing

  18. Automated Finger Spelling by Highly Realistic 3D Animation

    ERIC Educational Resources Information Center

    Adamo-Villani, Nicoletta; Beni, Gerardo

    2004-01-01

    We present the design of a new 3D animation tool for self-teaching (signing and reading) finger spelling the first basic component in learning any sign language. We have designed a highly realistic hand with natural animation of the finger motions. Smoothness of motion (in real time) is achieved via programmable blending of animation segments. The…

  19. Impaired Finger Dexterity in Parkinson's Disease Is Associated with Praxis Function

    ERIC Educational Resources Information Center

    Vanbellingen, T.; Kersten, B.; Bellion, M.; Temperli, P.; Baronti, F.; Muri, R.; Bohlhalter, S.

    2011-01-01

    A controversial concept suggests that impaired finger dexterity in Parkinson's disease may be related to limb kinetic apraxia that is not explained by elemental motor deficits such as bradykinesia. To explore the nature of dexterous difficulties, the aim of the present study was to assess the relationship of finger dexterity with ideomotor praxis…

  20. Rediscovering Ruth Faison Shaw and Her Finger-Painting Method

    ERIC Educational Resources Information Center

    Mayer, Veronica

    2005-01-01

    Ruth Faison Shaw was an art educator who developed a nontraditional educational perspective of teaching and a different vision about children's art. As such, she is considered by some to be the initiator of finger-painting in America (The History of Art Education Timeline 1930-1939, 2002.) Shaw developed the technique of finger-painting and a…

  1. Ultrasonography of the non-traumatic lesions of the fingers. Pictorial essay.

    PubMed

    Fodor, Daniela; Lungu, Andreea

    2013-06-01

    The purpose of this pictorial essay is to illustrate the ultrasonographic aspects of the non-traumatic lesions of the fingers. Diffuse (especially dactylitis) and localized (tumors, tophi, calcinosis, etc) lesions of the digits are discussed and illustrated. For a better understanding, the US images are compared with the clinical aspect of the pathological fingers.

  2. Treatment of mallet finger deformity with a modified palmaris longus tendon graft through a bone tunnel.

    PubMed

    Liu, Zengbing; Ma, Kai; Huang, Dong

    2018-01-01

    To investigate the clinical effect of treating mallet finger deformity using a modified palmaris longus tendon graft through a bone tunnel. Altogether, 21 patients with mallet finger deformity (16 men, 5 women; average age 31 years, range 19-47 years) were treated with a modified palmaris longus tendon graft through a bone tunnel during 18 months (2014-2016). Four index fingers, seven middle fingers, eight ring fingers, and two little fingers were treated for four cutting injuries, eleven finger sprains, four crush injuries, and two twist injuries (7 open and 14 closed injuries). Duration from injury to surgery was 9 h to 13 weeks. Three patients underwent surgery after 6 weeks of unsuccessful conservative treatment. No tendon was attached to the extensor tendon insertion in 16 patients, and 5 had residual tendon of <0.2 cm attached. All patients had distal segment flexion deformity and dorsiflexion disorder. Surgery comprised transverse penetration and vertical drilling of the base of the distal phalanx (2.0 and 2.5 mm diameter drills). Equal shallow semitendinosus pieces of the palmaris longus tendon (4 cm) were obtained from the sagittal end and were passed through a dorsal bone hole, emerging from a transverse bone hole. The two bundles were sutured to the main tendon. Tension was adjusted, and the broken ends were sutured. The distal interphalangeal joints were fixed in hyperextension. All patients were followed for 7-16 months (average 6.0 ± 0.3 months) postoperatively. All 21 patients had grade A wound healing, with no complications (e.g., necrotic wound, recurrence, joint stiffness). The mallet finger deformity was corrected with good appearance, no obvious abnormalities, and satisfactory flexion and extension. Two patients had a superficial wound infection. Each recovered after symptomatic treatment. One patient had a mild result, with limited extension. There were no recurrences. Results were evaluated according to Patel et al.'s system, which revealed 15 excellent and 5 good results (combined 95.23% rate), with 1 mild result (limited extension). Patients were satisfied with the appearance and function of the affected fingers, and the desired surgical end result was achieved. Use of this modified surgery for treating mallet finger deformity, especially with no or little tendon attached at the extensor tendon insertion, results in nearly anatomical reconstruction of the extensor tendon insertion. Its advantages include simple surgery, reliable fixation, fewer complications, and clinical efficacy.

  3. Kinematic Origins of Motor Inconsistency in Expert Pianists.

    PubMed

    Tominaga, Kenta; Lee, André; Altenmüller, Eckart; Miyazaki, Fumio; Furuya, Shinichi

    2016-01-01

    For top performers, including athletes and musicians, even subtle inconsistencies in rhythm and force during movement production decrease the quality of performance. However, extensive training over many years beginning in childhood is unable to perfect dexterous motor performance so that it is without any error. To gain insight into the biological mechanisms underlying the subtle defects of motor actions, the present study sought to identify the kinematic origins of inconsistency of dexterous finger movements in musical performance. Seven highly-skilled pianists who have won prizes at international piano competitions played a short sequence of tones with the right hand at a predetermined tempo. Time-varying joint angles of the fingers were recorded using a custom-made data glove, and the timing and velocity of the individual keystrokes were recorded from a digital piano. Both ridge and stepwise multiple regression analyses demonstrated an association of the inter-trial variability of the inter-keystroke interval (i.e., rhythmic inconsistency) with both the rotational velocity of joints of the finger used for a keystroke (i.e., striking finger) and the movement independence between the striking and non-striking fingers. This indicates a relationship between rhythmic inconsistency in musical performance and the dynamic features of movements in not only the striking finger but also the non-striking fingers. In contrast, the inter-trial variability of the key-descending velocity (i.e., loudness inconsistency) was associated mostly with the kinematic features of the striking finger at the moment of the keystroke. Furthermore, there was no correlation between the rhythmic and loudness inconsistencies. The results suggest distinct kinematic origins of inconsistencies in rhythm and loudness in expert musical performance.

  4. Validation of a Standalone Smartphone Application for Measuring Heart Rate Using Imaging Photoplethysmography.

    PubMed

    Poh, Ming-Zher; Poh, Yukkee C

    2017-08-01

    The aim of this study was to determine the accuracy of a freely available smartphone application, Cardiio app (Cardiio, Inc., Cambridge, MA), to measure heart rate from the finger or face using imaging photoplethysmography, by comparing against an FDA-cleared pulse oximeter at rest, and after moderate to vigorous exercise. A total of 40 healthy adults participated in this study. Participants engaged in a period of rest, followed by 3 min of moderate to vigorous intensity cycling on a stationary bicycle. Heart rate measurements were obtained from both the finger and face of participants using the Cardiio app at rest, immediately after exercise, 1-2 min after exercise, and 2-3 min after exercise. Concurrent heart rate readings using an FDA-cleared finger pulse oximeter served as the reference measurement. There was a very strong agreement between heart rate measurements obtained using the Cardiio app and the pulse oximeter, both at rest (r = 0.99 for finger, r = 0.97 for face) and after exercise (r = 0.99 for finger, r = 0.97 for face). At rest, the accuracy of the Cardiio app was ±1.58 beats per minute (bpm) (or ±2.27%) using the finger mode and ±2.28 bpm (or ±3.17%) for the face mode, compared to the pulse oximeter. After moderate to vigorous exercise, the accuracy of the Cardiio app was ±2.97 bpm (or ±2.79%) using the finger mode and ±5.31 bpm (or ±4.50%) for the face mode, compared to the pulse oximeter. The Cardiio app provided accurate heart rate measurements from the finger and face, both at rest and after exercise.

  5. The effect of night extension orthoses following surgical release of Dupuytren contracture: a single-center, randomized, controlled trial.

    PubMed

    Collis, Julie; Collocott, Shirley; Hing, Wayne; Kelly, Edel

    2013-07-01

    To clarify the efficacy and detrimental effects of orthoses used to maintain finger extension following surgical release of Dupuytren contracture. We conducted a single-center, randomized, controlled trial to investigate the effect of night extension orthoses on finger range of motion and hand function for 3 months following surgical release of Dupuytren contracture. We also wanted to determine how well finger extension was maintained in the total sample. We randomized 56 patients to receive a night extension orthosis plus hand therapy (n = 26) or hand therapy alone (n = 30). The primary outcome was total active extension of the operated fingers (°). Secondary outcomes were total active flexion of the operated fingers (°), active distal palmar crease (cm), grip strength (kg), and self-reported hand function using the Disabilities of the Arm, Shoulder, and Hand questionnaire (0-100 scale). There were no statistically significant differences between the no-orthosis and orthosis groups for total active extension or for any of the secondary outcomes. Between the first postoperative measure and 3 months after surgery, 62% of little fingers had maintained or improved total active extension. The use of a night extension orthosis in combination with standard hand therapy has no greater effect on maintaining finger extension than hand therapy alone in the 3 months following surgical release of Dupuytren contracture. Our results indicate that the practice of providing every patient with a night extension orthosis following surgical release of Dupuytren contracture may not be justified except for cases in which extension loss occurs after surgery. Our results also challenge clinicians to research ways of maintaining finger extension in a greater number of patients. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  6. Performance drifts in two-finger cyclical force production tasks performed by one and two actors.

    PubMed

    Hasanbarani, Fariba; Reschechtko, Sasha; Latash, Mark L

    2018-03-01

    We explored changes in the cyclical two-finger force performance task caused by turning visual feedback off performed either by the index and middle fingers of the dominant hand or by two index fingers of two persons. Based on an earlier study, we expected drifts in finger force amplitude and midpoint without a drift in relative phase. The subjects performed two rhythmical tasks at 1 Hz while paced by an auditory metronome. One of the tasks required cyclical changes in total force magnitude without changes in the sharing of the force between the two fingers. The other task required cyclical changes in the force sharing without changing total force magnitude. Subjects were provided with visual feedback, which showed total force magnitude and force sharing via cursor motion along the vertical and horizontal axes, respectively. Further, visual feedback was turned off, first on the variable that was not required to change and then on both variables. Turning visual feedback off led to a mean force drift toward lower magnitudes while force amplitude increased. There was a consistent drift in the relative phase in the one-hand task with the index finger leading the middle finger. No consistent relative phase drift was seen in the two-person tasks. The shape of the force cycle changed without visual feedback reflected in the lower similarity to a perfect cosine shape and in the higher time spent at lower force magnitudes. The data confirm findings of earlier studies regarding force amplitude and midpoint changes, but falsify predictions of an earlier proposed model with respect to the relative phase changes. We discuss factors that could contribute to the observed relative phase drift in the one-hand tasks including the leader-follower pattern generalized for two-effector tasks performed by one person.

  7. Factors affecting finger and hand pain in workers with HAVS.

    PubMed

    House, R; Krajnak, K; Jiang, D

    2016-06-01

    Pain and its management are important aspects of hand-arm vibration syndrome (HAVS). To determine the factors associated with finger and hand pain in workers with HAVS and, specifically, to assess the impact of several neurological variables as well as the vascular component of HAVS, grip strength and age. We assessed men with HAVS at a hospital occupational medicine clinic over 2 years. Subjects scored finger and hand pain separately using the Borg Scale (0-10). The possible predictors we evaluated included the Stockholm Neurological Scale (SNS) and Stockholm Vascular Scale (SVS) stages, current perception threshold (CPT), carpal tunnel syndrome (CTS), ulnar neuropathy, grip strength and age. We carried out nerve conduction testing to confirm the presence of CTS and ulnar neuropathy and measured CPT in the fingers at 2000 Hz, 250 Hz and 5 Hz corresponding to A-beta (large myelinated), A-delta (small myelinated) and C (unmyelinated) fibres, respectively. We calculated Spearman rank correlations to examine the relation between finger and hand pain and possible predictor variables. Among the 134 subjects, the median (25th-75th percentile) pain scores were 6 (4-8) for the fingers and 5 (1-7) for the hands. We found statistically significant correlations with finger pain for the SVS stage (r = 0.239; P < 0.01) and CTS (r = 0.184; P < 0.05). The only statistically significant correlation identified for hand pain was a negative correlation with grip strength (r = -0.185; P < 0.05). Management of finger and hand pain in HAVS should focus on the correlates we have identified. © The Author 2016. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Gene Discovery and Advances in Finger Millet [Eleusine coracana (L.) Gaertn.] Genomics-An Important Nutri-Cereal of Future.

    PubMed

    Sood, Salej; Kumar, Anil; Babu, B Kalyana; Gaur, Vikram S; Pandey, Dinesh; Kant, Lakshmi; Pattnayak, Arunava

    2016-01-01

    The rapid strides in molecular marker technologies followed by genomics, and next generation sequencing advancements in three major crops (rice, maize and wheat) of the world have given opportunities for their use in the orphan, but highly valuable future crops, including finger millet [ Eleusine coracana (L.) Gaertn.]. Finger millet has many special agronomic and nutritional characteristics, which make it an indispensable crop in arid, semi-arid, hilly and tribal areas of India and Africa. The crop has proven its adaptability in harsh conditions and has shown resilience to climate change. The adaptability traits of finger millet have shown the advantage over major cereal grains under stress conditions, revealing it as a storehouse of important genomic resources for crop improvement. Although new technologies for genomic studies are now available, progress in identifying and tapping these important alleles or genes is lacking. RAPDs were the default choice for genetic diversity studies in the crop until the last decade, but the subsequent development of SSRs and comparative genomics paved the way for the marker assisted selection in finger millet. Resistance gene homologs from NBS-LRR region of finger millet for blast and sequence variants for nutritional traits from other cereals have been developed and used invariably. Population structure analysis studies exhibit 2-4 sub-populations in the finger millet gene pool with separate grouping of Indian and exotic genotypes. Recently, the omics technologies have been efficiently applied to understand the nutritional variation, drought tolerance and gene mining. Progress has also occurred with respect to transgenics development. This review presents the current biotechnological advancements along with research gaps and future perspective of genomic research in finger millet.

  9. In-silico mining, type and frequency analysis of genic microsatellites of finger millet (Eleusine coracana (L.) Gaertn.): a comparative genomic analysis of NBS-LRR regions of finger millet with rice.

    PubMed

    Kalyana Babu, B; Pandey, Dinesh; Agrawal, P K; Sood, Salej; Kumar, Anil

    2014-05-01

    In recent years, the increased availability of the DNA sequences has given the possibility to develop and explore the expressed sequence tags (ESTs) derived SSR markers. In the present study, a total of 1956 ESTs of finger millet were used to find the microsatellite type, distribution, frequency and developed a total of 545 primer pairs from the ESTs of finger millet. Thirty-two EST sequences had more than two microsatellites and 1357 sequences did not have any SSR repeats. The most frequent type of repeats was trimeric motif, however the second place was occupied by dimeric motif followed by tetra-, hexa- and penta repeat motifs. The most common dimer repeat motif was GA and in case of trimeric SSRs, it was CGG. The EST sequences of NBS-LRR region of finger millet and rice showed higher synteny and were found on nearly same positions on the rice chromosome map. A total of eight, out of 15 EST based SSR primers were polymorphic among the selected resistant and susceptible finger millet genotypes. The primer FMBLEST5 could able to differentiate them into resistant and susceptible genotypes. The alleles specific to the resistant and susceptible genotypes were sequenced using the ABI 3130XL genetic analyzer and found similarity to NBS-LRR regions of rice and finger millet and contained the characteristic kinase-2 and kinase 3a motifs of plant R-genes belonged to NBS-LRR region. The In-silico and comparative analysis showed that the genes responsible for blast resistance can be identified, mapped and further introgressed through molecular breeding approaches for enhancing the blast resistance in finger millet.

  10. Stable Expression of mtlD Gene Imparts Multiple Stress Tolerance in Finger Millet

    PubMed Central

    Hema, Ramanna; Vemanna, Ramu S.; Sreeramulu, Shivakumar; Reddy, Chandrasekhara P.; Senthil-Kumar, Muthappa; Udayakumar, Makarla

    2014-01-01

    Finger millet is susceptible to abiotic stresses, especially drought and salinity stress, in the field during seed germination and early stages of seedling development. Therefore developing stress tolerant finger millet plants combating drought, salinity and associated oxidative stress in these two growth stages is important. Cellular protection through osmotic adjustment and efficient free radical scavenging ability during abiotic stress are important components of stress tolerance mechanisms in plants. Mannitol, an osmolyte, is known to scavenge hydroxyl radicals generated during various abiotic stresses and thereby minimize stress damage in several plant species. In this study transgenic finger millet plants expressing the mannitol biosynthetic pathway gene from bacteria, mannitol-1-phosphate dehydrogenase (mtlD), were developed through Agrobacterium tumefaciens-mediated genetic transformation. mtlD gene integration in the putative transgenic plants was confirmed by Southern blot. Further, performance of transgenic finger millet under drought, salinity and oxidative stress was studied at plant level in T1 generation and in T1 and T2 generation seedlings. Results from these experiments showed that transgenic finger millet had better growth under drought and salinity stress compared to wild-type. At plant level, transgenic plants showed better osmotic adjustment and chlorophyll retention under drought stress compared to the wild-type. However, the overall increase in stress tolerance of transgenics for the three stresses, especially for oxidative stress, was only marginal compared to other mtlD gene expressing plant species reported in the literature. Moreover, the Agrobacterium-mediated genetic transformation protocol developed for finger millet in this study can be used to introduce diverse traits of agronomic importance in finger millet. PMID:24922513

  11. Gene Discovery and Advances in Finger Millet [Eleusine coracana (L.) Gaertn.] Genomics—An Important Nutri-Cereal of Future

    PubMed Central

    Sood, Salej; Kumar, Anil; Babu, B. Kalyana; Gaur, Vikram S.; Pandey, Dinesh; Kant, Lakshmi; Pattnayak, Arunava

    2016-01-01

    The rapid strides in molecular marker technologies followed by genomics, and next generation sequencing advancements in three major crops (rice, maize and wheat) of the world have given opportunities for their use in the orphan, but highly valuable future crops, including finger millet [Eleusine coracana (L.) Gaertn.]. Finger millet has many special agronomic and nutritional characteristics, which make it an indispensable crop in arid, semi-arid, hilly and tribal areas of India and Africa. The crop has proven its adaptability in harsh conditions and has shown resilience to climate change. The adaptability traits of finger millet have shown the advantage over major cereal grains under stress conditions, revealing it as a storehouse of important genomic resources for crop improvement. Although new technologies for genomic studies are now available, progress in identifying and tapping these important alleles or genes is lacking. RAPDs were the default choice for genetic diversity studies in the crop until the last decade, but the subsequent development of SSRs and comparative genomics paved the way for the marker assisted selection in finger millet. Resistance gene homologs from NBS-LRR region of finger millet for blast and sequence variants for nutritional traits from other cereals have been developed and used invariably. Population structure analysis studies exhibit 2–4 sub-populations in the finger millet gene pool with separate grouping of Indian and exotic genotypes. Recently, the omics technologies have been efficiently applied to understand the nutritional variation, drought tolerance and gene mining. Progress has also occurred with respect to transgenics development. This review presents the current biotechnological advancements along with research gaps and future perspective of genomic research in finger millet. PMID:27881984

  12. Visualizing and quantifying the crossover from capillary fingering to viscous fingering in a rough fracture

    NASA Astrophysics Data System (ADS)

    Chen, Yi-Feng; Fang, Shu; Wu, Dong-Sheng; Hu, Ran

    2017-09-01

    Immiscible fluid-fluid displacement in permeable media is important in many subsurface processes, including enhanced oil recovery and geological CO2 sequestration. Controlled by capillary and viscous forces, displacement patterns of one fluid displacing another more viscous one exhibit capillary and viscous fingering, and crossover between the two. Although extensive studies investigated viscous and capillary fingering in porous media, a few studies focused on the crossover in rough fractures, and how viscous and capillary forces affect the crossover remains unclear. Using a transparent fracture-visualization system, we studied how the two forces impact the crossover in a horizontal rough fracture. Drainage experiments of water displacing oil were conducted at seven flow rates (capillary number log10Ca ranging from -7.07 to -3.07) and four viscosity ratios (M=1/1000,1/500,1/100 and 1/50). We consistently observed lower invading fluid saturations in the crossover zone. We also proposed a phase diagram for the displacement patterns in a rough fracture that is consistent with similar studies in porous media. Based on real-time imaging and statistical analysis of the invasion morphology, we showed that the competition between capillary and viscous forces is responsible for the saturation reduction in the crossover zone. In this zone, finger propagation toward the outlet (characteristic of viscous fingering) as well as void-filling in the transverse/backward directions (characteristic of capillary fingering), are both suppressed. Therefore, the invading fluid tends to occupy larger apertures with higher characteristic front velocity, promoting void-filling toward the outlet with thinner finger growth and resulting in a larger volume of defending fluid left behind.

  13. Spoof Detection for Finger-Vein Recognition System Using NIR Camera.

    PubMed

    Nguyen, Dat Tien; Yoon, Hyo Sik; Pham, Tuyen Danh; Park, Kang Ryoung

    2017-10-01

    Finger-vein recognition, a new and advanced biometrics recognition method, is attracting the attention of researchers because of its advantages such as high recognition performance and lesser likelihood of theft and inaccuracies occurring on account of skin condition defects. However, as reported by previous researchers, it is possible to attack a finger-vein recognition system by using presentation attack (fake) finger-vein images. As a result, spoof detection, named as presentation attack detection (PAD), is necessary in such recognition systems. Previous attempts to establish PAD methods primarily focused on designing feature extractors by hand (handcrafted feature extractor) based on the observations of the researchers about the difference between real (live) and presentation attack finger-vein images. Therefore, the detection performance was limited. Recently, the deep learning framework has been successfully applied in computer vision and delivered superior results compared to traditional handcrafted methods on various computer vision applications such as image-based face recognition, gender recognition and image classification. In this paper, we propose a PAD method for near-infrared (NIR) camera-based finger-vein recognition system using convolutional neural network (CNN) to enhance the detection ability of previous handcrafted methods. Using the CNN method, we can derive a more suitable feature extractor for PAD than the other handcrafted methods using a training procedure. We further process the extracted image features to enhance the presentation attack finger-vein image detection ability of the CNN method using principal component analysis method (PCA) for dimensionality reduction of feature space and support vector machine (SVM) for classification. Through extensive experimental results, we confirm that our proposed method is adequate for presentation attack finger-vein image detection and it can deliver superior detection results compared to CNN-based methods and other previous handcrafted methods.

  14. Spoof Detection for Finger-Vein Recognition System Using NIR Camera

    PubMed Central

    Nguyen, Dat Tien; Yoon, Hyo Sik; Pham, Tuyen Danh; Park, Kang Ryoung

    2017-01-01

    Finger-vein recognition, a new and advanced biometrics recognition method, is attracting the attention of researchers because of its advantages such as high recognition performance and lesser likelihood of theft and inaccuracies occurring on account of skin condition defects. However, as reported by previous researchers, it is possible to attack a finger-vein recognition system by using presentation attack (fake) finger-vein images. As a result, spoof detection, named as presentation attack detection (PAD), is necessary in such recognition systems. Previous attempts to establish PAD methods primarily focused on designing feature extractors by hand (handcrafted feature extractor) based on the observations of the researchers about the difference between real (live) and presentation attack finger-vein images. Therefore, the detection performance was limited. Recently, the deep learning framework has been successfully applied in computer vision and delivered superior results compared to traditional handcrafted methods on various computer vision applications such as image-based face recognition, gender recognition and image classification. In this paper, we propose a PAD method for near-infrared (NIR) camera-based finger-vein recognition system using convolutional neural network (CNN) to enhance the detection ability of previous handcrafted methods. Using the CNN method, we can derive a more suitable feature extractor for PAD than the other handcrafted methods using a training procedure. We further process the extracted image features to enhance the presentation attack finger-vein image detection ability of the CNN method using principal component analysis method (PCA) for dimensionality reduction of feature space and support vector machine (SVM) for classification. Through extensive experimental results, we confirm that our proposed method is adequate for presentation attack finger-vein image detection and it can deliver superior detection results compared to CNN-based methods and other previous handcrafted methods. PMID:28974031

  15. Prehension Synergies in Three Dimensions

    PubMed Central

    Shim, Jae Kun; Latash, Mark L.; Zatsiorsky, Vladimir M.

    2010-01-01

    The goal of this study was to investigate the conjoint changes of digit forces/moments in 3 dimensions during static prehension under external torques acting on the object in one plane. The experimental paradigm was similar to holding a book vertically in the air where the center of mass of the book is located farther from the hand than the points of digit contacts. Three force and 3 moment components from each digit were recorded during static prehension of a customized handle. Subjects produced forces and moments in all 3 directions, although the external torques were exerted on the handheld object about only the Z-axis. The 3-dimensional response to a 2-dimensional task was explained by the cause– effect chain effects prompted by the noncollinearity of the normal forces of the thumb and the 4 fingers (represented by the “virtual finger”). Because the forces are not collinear (not along the same line), they generate moments of force about X- and Y-axes that are negated by the finger forces along the Y- and X-directions. The magnitudes of forces produced by lateral fingers (index and little) with longer moment arms were larger compared with the central fingers (middle and ring). At the virtual finger (an imaginary digit whose mechanical action is equivalent to the summed action of the 4 fingers) level, the relative contribution of different fractions of the resistive moment produced by subjects did not depend on the torque magnitude. We conclude that the CNS 1) solves a planar prehension task by producing forces and moments in all 3 directions, 2) uses mechanical advantage of fingers, and 3) shares the total torque among finger forces and moments in a particular way disregarding the torque magnitude. PMID:15456799

  16. From viscous fingers to wormholes - interactions between structures emerging in unstable growth

    NASA Astrophysics Data System (ADS)

    Budek, Agnieszka; Kwiatkowski, Kamil; Szymczak, Piotr

    2017-04-01

    Dissolution of porous and fractured rock can lead to instabilities, where long finger-like channels or „wormholes" are spontaneously formed, focusing the majority of the flow. Formation of those structures leads to a significant increase in permeability of the system, and is thus important in many engineering applications, e.g. in acidization during oil and gas recovery stimulation. In this communication, we analyse this process using two different numerical models (a network model and a Darcy scale one). We show that wormhole patterns depend strongly on the amount of soluble material in the system, as quantified by the permeability contrast κ between the dissolved and undissolved medium. For small and intermediate values of κ, a large number of relatively thin and strongly interacting channels are formed. The longer channels attract shorter ones, with loops being formed as a result. However, for large values of κ the pattern gets sparse with individual wormholes repelling each other. Interestingly, a similar succession of patterns can be observed in viscous fingering in a rectangular network of channels. In such a system, anisotropy of the network promotes the growth of long and thin fingers which behave similarly to wormholes. The attraction rate between growing fingers depends strongly on the viscosity ratio, I. The latter plays a role similar to that of permeability ratio for dissolution of porous material. To explain this behaviour, we have created a simple analytical model of interacting fingers, allowing us to quantify their mutual interaction as a function of finger lengths, distances between them and - most importantly - relative permeabilities. The theoretical predictions are in a good agreement with simulation data for both dissolution and viscous fingering processes.

  17. Differences of Cutaneous Two-Point Discrimination Thresholds Among Students in Different Years of a Chiropractic Program.

    PubMed

    Dane, Andrew B; Teh, Elaine; Reckelhoff, Kenneth E; Ying, Pee Kui

    2017-09-01

    The aim of this study was to investigate if there were differences in the two-point discrimination (2-PD) of fingers among students at different stages of a chiropractic program. This study measured 2-PD thresholds for the dominant and nondominant index finger and dominant and nondominant forearm in groups of students in a 4-year chiropractic program at the International Medical University in Kuala Lumpur, Malaysia. Measurements were made using digital calipers mounted on a modified weighing scale. Group comparisons were made among students for each year of the program (years 1, 2, 3, and 4). Analysis of the 2-PD threshold for differences among the year groups was performed with analysis of variance. The mean 2-PD threshold of the index finger was higher in the students who were in the higher year groups. Dominant-hand mean values for year 1 were 2.93 ± 0.04 mm and 1.69 ± 0.02 mm in year 4. There were significant differences at finger sites (P < .05) among all year groups compared with year 1. There were no significant differences measured at the dominant forearm between any year groups (P = .08). The nondominant fingers of the year groups 1, 2, and 4 showed better 2-PD compared with the dominant finger. There was a significant difference (P = .005) between the nondominant (1.93 ± 1.15) and dominant (2.27 ± 1.14) fingers when all groups were combined (n = 104). The results of this study demonstrated that the finger 2-PD of the chiropractic students later in the program was more precise than that of students in the earlier program. Copyright © 2017. Published by Elsevier Inc.

  18. Getting a grip: different actions and visual guidance of the thumb and finger in precision grasping.

    PubMed

    Melmoth, Dean R; Grant, Simon

    2012-10-01

    We manipulated the visual information available for grasping to examine what is visually guided when subjects get a precision grip on a common class of object (upright cylinders). In Experiment 1, objects (2 sizes) were placed at different eccentricities to vary the relative proximity to the participant's (n = 6) body of their thumb and finger contact positions in the final grip orientations, with vision available throughout or only for movement programming. Thumb trajectories were straighter and less variable than finger paths, and the thumb normally made initial contact with the objects at a relatively invariant landing site, but consistent thumb first-contacts were disrupted without visual guidance. Finger deviations were more affected by the object's properties and increased when vision was unavailable after movement onset. In Experiment 2, participants (n = 12) grasped 'glow-in-the-dark' objects wearing different luminous gloves in which the whole hand was visible or the thumb or the index finger was selectively occluded. Grip closure times were prolonged and thumb first-contacts disrupted when subjects could not see their thumb, whereas occluding the finger resulted in wider grips at contact because this digit remained distant from the object. Results were together consistent with visual feedback guiding the thumb in the period just prior to contacting the object, with the finger more involved in opening the grip and avoiding collision with the opposite contact surface. As people can overtly fixate only one object contact point at a time, we suggest that selecting one digit for online guidance represents an optimal strategy for initial grip placement. Other grasping tasks, in which the finger appears to be used for this purpose, are discussed.

  19. Lead inhibition of DNA-binding mechanism of Cys(2)His(2) zinc finger proteins.

    PubMed

    Hanas, J S; Rodgers, J S; Bantle, J A; Cheng, Y G

    1999-11-01

    The association of lead with chromatin in cells suggests that deleterious metal effects may in part be mediated through alterations in gene function. To elucidate if and how lead may alter DNA binding of cysteine-rich zinc finger proteins, lead ions were analyzed for their ability to alter the DNA binding mechanism of the Cys(2)His(2) zinc finger protein transcription factor IIIA (TFIIIA). As assayed by DNase I protection, the interaction of TFIIIA with the 50-bp internal control region of the 5S ribosomal gene was partially inhibited by 5 microM lead ions and completely inhibited by 10 to 20 microM lead ions. Preincubation of free TFIIIA with lead resulted in DNA-binding inhibition, whereas preincubation of a TFIIIA/5S RNA complex with lead did not result in DNA-binding inhibition. Because 5S RNA binds TFIIIA zinc fingers, this result is consistent with an inhibition mechanism via lead binding to zinc fingers. The complete loss of DNase I protection on the 5S gene indicates the mechanism of inhibition minimally involves the N-terminal fingers of TFIIIA. Inhibition was not readily reversible and occurred in the presence of an excess of beta-mercaptoethanol. Inhibition kinetics were fast, progressing to completion in approximately 5 min. Millimolar concentrations of sulfhydryl-specific arsenic ions were not inhibitory for TFIIIA binding. Micromolar concentrations of lead inhibited DNA binding by Sp1, another Cys(2)His(2) finger protein, but not by the nonfinger protein AP2. Inhibition of Cys(2)His(2) zinc finger transcription factors by lead ions at concentrations near those known to have deleterious physiological effects points to new molecular mechanisms for lead toxicity in promoting disease.

  20. Normative data for neuromuscular assessment of the hand-arm vibration syndrome and its retrospective applications in Korean male workers.

    PubMed

    Ahn, Ryeok; Yoo, Cheol-In; Lee, Hun; Sim, Chang-Sun; Sung, Joo Hyun; Yoon, Jae-Kook; Shin, Song-Woo

    2013-10-01

    The purpose of this study was to describe normative data for the neuromuscular assessments of the hand-arm vibration syndrome (HAVS) in Korean. Data for the vibrotactile perception threshold (VPT) at three frequencies (31.5, 125, and 250 Hz), the hand grip strength (HGS), the finger pinch strength (FPS), the finger tapping test, and the Purdue pegboard tests were collected from 120 male office workers aged 30-59 years with no prior history of regular use of handheld vibrating tools. The collected data were compared with the results of a similar study of shipbuilding workers in order to investigate the diagnostic utility of clinical test for HAVS. The mean VPT values indicate that no significant differences were observed between the dominant and non-dominant hands or between the index and little fingers. The age group of 30s was highly sensitive to vibration input with a peak in sensitivity at 125 Hz among all age groups. In neuromuscular performance, dominant hands are usually more accurate, dexterous, and functionally quicker than non-dominant hands. The index finger was superior to the little finger in the finger tapping counts (p < 0.05). Also, FPS was greater in the index finger than in the middle finger (p < 0.05). The HGS of dominant hands was significantly stronger than that of non-dominant hands (p < 0.05). When the normative data were compared with the data of shipyard workers exposed to vibration, there were statistically significant differences in VPT and neuromuscular functions. The current data can be used to evaluate HAVS in Korean male workers. Age is an important factor for VPT.

  1. The fragrance hand immersion study - an experimental model simulating real-life exposure for allergic contact dermatitis on the hands.

    PubMed

    Heydorn, S; Menné, T; Andersen, K E; Bruze, M; Svedman, C; Basketter, D; Johansen, J D

    2003-06-01

    Recently, we showed that 10 x 2% of consecutively patch-tested hand eczema patients had a positive patch test to a selection of fragrances containing fragrances relevant to hand exposure. In this study, we used repeated skin exposure to a patch test-positive fragrance allergen in patients previously diagnosed with hand eczema to explore whether immersion of fingers in a solution with or without the patch-test-positive fragrance allergen would cause or exacerbate hand eczema on the exposed finger. The study was double blinded and randomized. All participants had a positive patch test to either hydroxycitronellal or Lyral (hydroxyisohexyl 3-cyclohexene carboxaldehyde). Each participant immersed a finger from each hand, once a day, in a solution containing the fragrance allergen or placebo. During the first 2 weeks, the concentration of fragrance allergen in the solution was low (approximately 10 p.p.m.), whilst during the following 2 weeks, the concentration was relatively high (approximately 250 p.p.m.), imitating real-life exposure to a household product like dishwashing liquid diluted in water and the undiluted product, respectively. Evaluation was made using a clinical scale and laser Doppler flow meter. 3 of 15 hand eczema patients developed eczema on the finger immersed in the fragrance-containing solution, 3 of 15 on the placebo finger and 3 of 15 on both fingers. Using this experimental exposure model simulating real-life exposure, we found no association between immersion of a finger in a solution containing fragrance and development of clinically visible eczema on the finger in 15 participants previously diagnosed with hand eczema and with a positive patch test to the fragrance in question.

  2. Biomechanical analysis of the circular friction hand massage.

    PubMed

    Ryu, Jeseong; Son, Jongsang; Ahn, Soonjae; Shin, Isu; Kim, Youngho

    2015-01-01

    A massage can be beneficial to relieve muscle tension on the neck and shoulder area. Various massage systems have been developed, but their motions are not uniform throughout different body parts nor specifically targeted to the neck and shoulder areas. Pressure pattern and finger movement trajectories of the circular friction hand massage on trapezius, levator scapulae, and deltoid muscles were determined to develop a massage system that can mimic the motion and the pressure of the circular friction massage. During the massage, finger movement trajectories were measured using a 3D motion capture system, and finger pressures were simultaneously obtained using a grip pressure sensor. Results showed that each muscle had different finger movement trajectory and pressure pattern. The trapezius muscle experienced a higher pressure, longer massage time (duration of pressurization), and larger pressure-time integral than the other muscles. These results could be useful to design a better massage system simulating human finger movements.

  3. EVA space suit Evaporative Cooling/Heating Glove System (ECHGS)

    NASA Technical Reports Server (NTRS)

    Coss, F. A.

    1976-01-01

    A new astronaut glove, the Evaporative Cooling/Heating Glove System (ECHGS), was designed and developed to allow the handling of objects between -200 F and +200 F. Active heating elements, positioned at each finger pad, provide additional heat to the finger pads from the rest of the finger. A water evaporative cooling system provides cooling by the injection of water to the finger areas and the subsequent direct evaporation to space. Thin, flexible insulation has been developed for the finger areas to limit thermal conductivity. Component and full glove tests have shown that the glove meets and exceeds the requirements to hold a 11/2 inch diameter bar at + or - 200 F for three minutes within comfort limits. The ECHGS is flexible, lightweight and comfortable. Tactility is reasonable and small objects can be identified especially by the fingertips beyond the one half width active elements.

  4. Finger Vein Recognition Based on Local Directional Code

    PubMed Central

    Meng, Xianjing; Yang, Gongping; Yin, Yilong; Xiao, Rongyang

    2012-01-01

    Finger vein patterns are considered as one of the most promising biometric authentication methods for its security and convenience. Most of the current available finger vein recognition methods utilize features from a segmented blood vessel network. As an improperly segmented network may degrade the recognition accuracy, binary pattern based methods are proposed, such as Local Binary Pattern (LBP), Local Derivative Pattern (LDP) and Local Line Binary Pattern (LLBP). However, the rich directional information hidden in the finger vein pattern has not been fully exploited by the existing local patterns. Inspired by the Webber Local Descriptor (WLD), this paper represents a new direction based local descriptor called Local Directional Code (LDC) and applies it to finger vein recognition. In LDC, the local gradient orientation information is coded as an octonary decimal number. Experimental results show that the proposed method using LDC achieves better performance than methods using LLBP. PMID:23202194

  5. The cognitive foundations of early arithmetic skills: It is counting and number judgment, but not finger gnosis, that count.

    PubMed

    Long, Imogen; Malone, Stephanie A; Tolan, Anne; Burgoyne, Kelly; Heron-Delaney, Michelle; Witteveen, Kate; Hulme, Charles

    2016-12-01

    Following on from ideas developed by Gerstmann, a body of work has suggested that impairments in finger gnosis may be causally related to children's difficulties in learning arithmetic. We report a study with a large sample of typically developing children (N=197) in which we assessed finger gnosis and arithmetic along with a range of other relevant cognitive predictors of arithmetic skills (vocabulary, counting, and symbolic and nonsymbolic magnitude judgments). Contrary to some earlier claims, we found no meaningful association between finger gnosis and arithmetic skills. Counting and symbolic magnitude comparison were, however, powerful predictors of arithmetic skills, replicating a number of earlier findings. Our findings seriously question theories that posit either a simple association or a causal connection between finger gnosis and the development of arithmetic skills. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  6. Aesthetic finger prosthesis with silicone biomaterial

    PubMed Central

    Raghu, K M; Gururaju, C R; Sundaresh, K J; Mallikarjuna, Rachappa

    2013-01-01

    The fabrication of finger prosthesis is as much an art as it is science. The ideally constructed prosthesis must duplicate the missing structures so precisely that patients can appear in public without fear of attracting unwanted attraction. A 65-years-old patient reported with loss of his right index finger up to the second phalanx and wanted to get it replaced. An impression of the amputated finger and donor were made. A wax pattern of the prosthesis was fabricated using the donor impression; a trial was performed and flasked. Medical grade silicone was intrinsically stained to match the skin tone, following which it was packed, processed and finished. This clinical report describes a method of attaining retention by selective scoring of the master cast of partially amputated finger to enhance the vacuum effect at par with the proportional distribution of the positive forces on the tissues exerted by the prosthesis. PMID:23975917

  7. Two-finger (TF) SPUDT cells.

    PubMed

    Martin, Guenter; Biryukov, Sergey V; Schmidt, Hagen; Steiner, Bernd; Wall, Bert

    2011-03-01

    SPUDT cells including two fingers are only known thus far for so-called NSPUDT directions. In that case, usual solid-finger cells are used. The purpose of the present paper is to find SPUDT cell types consisting of two fingers only for pure mode directions. Two-finger (TF) cells for pure mode directions on substrates like 128°YX LiNbO(3) and YZ LiNbO(3) were found by means of an optimization procedure. The forward direction of a TF-cell SPUDT on 128°YX LiNbO(3) was determined experimentally. The properties of the new cells are compared with those of conventional SPUDT cells. The reflectivity of TF cells on 128°YX LiNbO(3) turns out to be two to three times larger than that of distributed acoustic reflection transducer (DART) and Hanma-Hunsinger cells at the same metal layer thickness.

  8. Finger vein recognition based on local directional code.

    PubMed

    Meng, Xianjing; Yang, Gongping; Yin, Yilong; Xiao, Rongyang

    2012-11-05

    Finger vein patterns are considered as one of the most promising biometric authentication methods for its security and convenience. Most of the current available finger vein recognition methods utilize features from a segmented blood vessel network. As an improperly segmented network may degrade the recognition accuracy, binary pattern based methods are proposed, such as Local Binary Pattern (LBP), Local Derivative Pattern (LDP) and Local Line Binary Pattern (LLBP). However, the rich directional information hidden in the finger vein pattern has not been fully exploited by the existing local patterns. Inspired by the Webber Local Descriptor (WLD), this paper represents a new direction based local descriptor called Local Directional Code (LDC) and applies it to finger vein recognition. In LDC, the local gradient orientation information is coded as an octonary decimal number. Experimental results show that the proposed method using LDC achieves better performance than methods using LLBP.

  9. Brain activity during bilateral rapid alternate finger tapping measured with magnetoencephalography

    NASA Astrophysics Data System (ADS)

    Fukuda, Hiroshi; Odagaki, Masato; Hiwaki, Osamu; Kodabashi, Atsushi; Fujimoto, Toshiro

    2009-04-01

    Using magnetoencephalography (MEG), brain regions involved in an alternate bimanual tapping task by index fingers triggered with spontaneous timing were investigated. The tapping mode in which both index fingers moved simultaneously was interlaced during the task. The groups of the alternate tapping (AL mode) and the simultaneous tapping (SI mode) were extracted from the successive alternating taps with a histogram of intervals between the right and left index fingers. MEG signals in each mode were averaged separately before and after the tapping initiation of the dominant index finger. The activities of the contralateral sensorimotor cortex before and after the tapping initiation in the AL mode were larger than that in the SI mode. The result indicates that the activity of the contralateral sensorimotor cortex depends on the degree of achievement in the difficult motor task such as the voluntary alternate tapping movements.

  10. Experimental characterization of 3-dimensional gravity-driven fingering in a porous medium

    NASA Astrophysics Data System (ADS)

    Dalbe, Marie-Julie; Juanes, Ruben

    2017-11-01

    When water infiltrates a dry porous media, a gravity-driven instability can be observed. Water will penetrate the porous media along preferential paths, called fingers. This gravity-driven unstable multiphase flow has important implications for natural phenomena such as rainwater infiltration in soil and secondary oil migration in reservoir rocks. While several experimental and numerical studies have described the instability in 2-dimensional (2D) settings, fundamental questions remain on the morphodynamics of gravity fingering in 3D. We developed a 3D experimental set-up based on planar laser-induced fluorescence of index-matched fluids that allows us to image this phenomenon dynamically. We study the impact of some crucial parameters such as rainfall rate or grain size on the finger size and velocity. In addition, experiments in stratified media reveal interesting dynamics of finger flow across material interfaces, an essential aspect towards the understanding of water infiltration in soils.

  11. Evaluation of hole sizes in structures requiring EVA services as a means to prevent gloved-hand finger entrapment

    NASA Technical Reports Server (NTRS)

    Rajulu, Sudhakar L.; Klute, Glenn K.

    1993-01-01

    One of the concerns of Space Station designers was making sure that the suited crewmembers' gloved fingers are not trapped in the holes that may be present in the structures during EVA activities. A study was conducted on 11 subjects to determine the minimum and maximum possible hole sizes that would eliminate the possibility of finger entrapment. Subjects wore pressurized gloves and attempted to insert their fingers into holes of various sizes. Based on the experimental results, it is recommended that the smallest diameter should be less than 13.0 mm and the largest diameter should be greater than 35.0 mm in order to eliminate the possibility of finger entrapment while wearing gloves. It is also recommended that the current requirements specified by the MSIS-STD-3000 (Section 6.3.3.4) should be modified accordingly.

  12. Non-Contacting Finger Seals Static Performance Test Results at Ambient and High Temperatures

    NASA Technical Reports Server (NTRS)

    Proctor, Margaret P.

    2016-01-01

    The non-contacting finger seal is an advanced seal concept with potential to reduce specific fuel consumption in gas turbine engines by 2 to 3 percent with little to no wear of the seal or rotor. Static performance tests and bind-up tests of eight different non-contacting finger seal configurations were conducted in air at pressure differentials up to 689.4 kPa and temperatures up to 922 K. Four of the seals tested were designed to have lift pads concentric to a herringbone-grooved rotor which generates hydrodynamic lift when rotating. The remaining seals were tested with a smooth rotor; one seal had a circumferential taper and one had an axial taper on the lift pad inner diameter to create hydrodynamic lift during rotation. The effects of the aft finger axial thickness and of the forward finger inner diameter on leakage performance were investigated as well and compared to analytical predictions.

  13. A new approach to depict bone surfaces in finger imaging using photoacoustic tomography

    NASA Astrophysics Data System (ADS)

    Biswas, S. K.; van Es, P.; Steenbergen, W.; Manohar, S.

    2015-03-01

    Imaging the vasculature close around the finger joints is of interest in the field of rheumatology. Locally increased vasculature in the synovial membrane of these joints can be a marker for rheumatoid arthritis. In previous work we showed that part of the photoacoustically induced ultrasound from the epidermis reflects on the bone surface within the finger. These reflected signals could be wrongly interpreted as new photoacoustic sources. In this work we show that a conventional ultrasound reconstruction algorithm, that considers the skin as a collection of ultrasound transmitters and the PA tomography probe as the detector array, can be used to delineate bone surfaces of a finger. This can in the future assist in the localization of the joint gaps. This can provide us with a landmark to localize the region of the inflamed synovial membrane. We test the approach on finger mimicking phantoms.

  14. Determining the number of fingers in the lifting Hele-Shaw problem

    NASA Astrophysics Data System (ADS)

    Miranda, Jose; Dias, Eduardo

    2013-11-01

    The lifting Hele-Shaw cell flow is a variation of the celebrated radial viscous fingering problem for which the upper cell plate is lifted uniformly at a specified rate. This procedure causes the formation of intricate interfacial patterns. Most theoretical studies determine the total number of emerging fingers by maximizing the linear growth rate, but this generates discrepancies between theory and experiments. In this work, we tackle the number of fingers selection problem in the lifting Hele-Shaw cell by employing the recently proposed maximum-amplitude criterion. Our linear stability analysis accounts for the action of capillary, viscous normal stresses, and wetting effects, as well as the cell confinement. The comparison of our results with very precise laboratory measurements for the total number of fingers shows a significantly improved agreement between theoretical predictions and experimental data. We thank CNPq (Brazilian Sponsor) for financial support.

  15. An Individual Finger Gesture Recognition System Based on Motion-Intent Analysis Using Mechanomyogram Signal

    PubMed Central

    Ding, Huijun; He, Qing; Zhou, Yongjin; Dan, Guo; Cui, Song

    2017-01-01

    Motion-intent-based finger gesture recognition systems are crucial for many applications such as prosthesis control, sign language recognition, wearable rehabilitation system, and human–computer interaction. In this article, a motion-intent-based finger gesture recognition system is designed to correctly identify the tapping of every finger for the first time. Two auto-event annotation algorithms are firstly applied and evaluated for detecting the finger tapping frame. Based on the truncated signals, the Wavelet packet transform (WPT) coefficients are calculated and compressed as the features, followed by a feature selection method that is able to improve the performance by optimizing the feature set. Finally, three popular classifiers including naive Bayes (NBC), K-nearest neighbor (KNN), and support vector machine (SVM) are applied and evaluated. The recognition accuracy can be achieved up to 94%. The design and the architecture of the system are presented with full system characterization results. PMID:29167655

  16. Non-Contacting Finger Seals Static Performance Test Results at Ambient and High Temperatures

    NASA Technical Reports Server (NTRS)

    Proctor, Margaret P.

    2016-01-01

    The non-contacting finger seal is an advanced seal concept with potential to reduce specific fuel consumption in gas turbine engines by 2 to 3 with little to no wear of the seal or rotor. Static performance tests and bind-up tests of eight different non-contacting finger seal configurations were conducted in air at pressure differentials up to 689.4 kPa and temperatures up to 922 K. Four of the seals tested were designed to have lift pads concentric to a herringbone-grooved rotor which generates hydrodynamic lift when rotating. The remaining seals were tested with a smooth rotor; one seal had a circumferential taper and one had an axial taper on the lift pad inner diameter to create hydrodynamic lift during rotation. The effects of the aft finger axial thickness and of the forward finger inner diameter on leakage performance were investigated as well and compared to analytical predictions.

  17. Unique Use of Cross-Finger Flap for Reconstruction of an Index Fingertip Electrical Injury

    DTIC Science & Technology

    2014-01-01

    5-0 nylon suture (Figures 3, 4). A full thickness (FT) skin graft was harvested from the left groin and was used to cover the donor long finger...following day and returned for weekly wound examinations. The tie-over bolster was removed from the FT skin graft of the left dorsal middle finger on

  18. Birth Outcomes across Three Rural-Urban Typologies in the Finger Lakes Region of New York

    ERIC Educational Resources Information Center

    Strutz, Kelly L.; Dozier, Ann M.; van Wijngaarden, Edwin; Glantz, J. Christopher

    2012-01-01

    Purpose: The study is a descriptive, population-based analysis of birth outcomes in the New York State Finger Lakes region designed to determine whether perinatal outcomes differed across 3 rural typologies. Methods: Hospital birth data for the Finger Lakes region from 2006 to 2007 were used to identify births classified as low birthweight (LBW),…

  19. Finger jointing green southern yellow pine with a soy-based adhesive

    Treesearch

    Philip H. Steele; Roland E. Kreibicha; Petrus J. Steynberg; Richard W. Hemingway

    1998-01-01

    The authors present results of laboratory tests for a soy-based adhesive to bond southern yellow pine using the finger-jointing method. There was some reason to suspect that finger jointing of southern yellow pine (SYP) with the honeymoon system using soy-based adhesive might prove more difficult than for western species. The Wood Handbook classes western species in...

  20. Laser cutting system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dougherty, Thomas J

    A workpiece cutting apparatus includes a laser source, a first suction system, and a first finger configured to guide a workpiece as it moves past the laser source. The first finger includes a first end provided adjacent a point where a laser from the laser source cuts the workpiece, and the first end of the first finger includes an aperture in fluid communication with the first suction system.

  1. The Power of a Soccer Ball: A Traumatic Open Finger Dislocation-A Rare Case Presentation.

    PubMed

    Dülgeroğlu, Turan Cihan; Metineren, Hasan; Aydın, Ekrem; Dülgeroğlu, Ayşegül

    2015-01-01

    Proximal interphalangeal joint dislocations are injuries observed frequently and caused by axial loading on the finger in the extension. In this paper we present a traumatic open finger dislocation due to a ball hitting a wrestler. It was successfully treated with reduction and the volar plate and collateral bond fixation were applied with absorbable sutures.

  2. Nature and Culture of Finger Counting: Diversity and Representational Effects of an Embodied Cognitive Tool

    ERIC Educational Resources Information Center

    Bender, Andrea; Beller, Sieghard

    2012-01-01

    Studies like the one conducted by Domahs et al. (2010, in Cognition) corroborate that finger counting habits affect how numbers are processed, and legitimize the assumption that this effect is culturally modulated. The degree of cultural diversity in finger counting, however, has been grossly underestimated in the field at large, which, in turn,…

  3. Surface electromyogram for the control of anthropomorphic teleoperator fingers.

    PubMed

    Gupta, V; Reddy, N P

    1996-01-01

    Growing importance of telesurgery has led to the need for the development of synergistic control of anthropomorphic teleoperators. Synergistic systems can be developed using direct biological control. The purpose of this study was to develop techniques for direct biocontrol of anthropomorphic teleoperators using surface electromyogram (EMG). A computer model of a two finger teleoperator was developed and controlled using surface EMG from the flexor digitorum superficialis during flexion-extension of the index finger. The results of the study revealed a linear relationship between the RMS EMG and the flexion-extension of the finger model. Therefore, surface EMG can be used as a direct biocontrol for teleoperators and in VR applications.

  4. A hierarchical classification method for finger knuckle print recognition

    NASA Astrophysics Data System (ADS)

    Kong, Tao; Yang, Gongping; Yang, Lu

    2014-12-01

    Finger knuckle print has recently been seen as an effective biometric technique. In this paper, we propose a hierarchical classification method for finger knuckle print recognition, which is rooted in traditional score-level fusion methods. In the proposed method, we firstly take Gabor feature as the basic feature for finger knuckle print recognition and then a new decision rule is defined based on the predefined threshold. Finally, the minor feature speeded-up robust feature is conducted for these users, who cannot be recognized by the basic feature. Extensive experiments are performed to evaluate the proposed method, and experimental results show that it can achieve a promising performance.

  5. Impending gangrene of fingers by constriction bands of mother's hair mistaken as pernio by parents: A case series of 10 infants.

    PubMed

    Bhat, Towseef Ahmad; Ali, Zameer; Moten, Tarseem Lal; Sofi, Aabid Hussain; Mir, Furqaan; Gulzar, Amara

    2017-01-01

    Long harsh winter in Kashmir Valley increase the incidence of pernio in children so much that common people consider every hand swelling as pernio. 10 Infants over two years were brought to our hospital as cases of pernio involving fingers. All the infants came out to be cases of impending gangrene due to mother's hair as constriction bands around fingers. Impending gangrene of fingers in infants due to mother hair as constriction band is very rare. However its symptoms overlap with symptoms of peripheral cold injuries and can be easily mistaken for each other by people.

  6. More efficient swimming by spreading your fingers

    NASA Astrophysics Data System (ADS)

    van de Water, Willem; van Houwelingen, Josje; Willemsen, Dennis; Breugem, Wim Paul; Westerweel, Jerry; Delfos, Rene; Grift, Ernst Jan

    2016-11-01

    A tantalizing question in free-style swimming is whether the stroke efficiency during the pull phase depends on spreading the fingers. It is a subtle effect-not more than a few percent-but it could make a big difference in a race. We measure the drag of arm models with increasing finger spreading in a wind tunnel and compare forces and moments to the results of immersed boundary simulations. Virtual arms were used in the simulations and their 3D-printed real versions in the experiment. We find an optimal finger spreading, accompanied by a marked increase of coherent vortex shedding. A simple actuator disk model explains this optimum.

  7. Biofeedback therapy for migraine headaches.

    PubMed

    Turin, A; Johnson, W G

    1976-04-01

    We studied the biofeedback treatment of migraine headaches, attempting to control for some of the methodological limitations of previous work. Seven individuals suffering from migraine headache were trained in the usual finger warming procedure with the omission of autogenic phrases. Additionally, to control for placebo-expectance effects, three of these subjects received training in finger cooling prior to warming. With training in finger warming, headache activity was substantially reduced. In contrast, headache activity either remained at base line levels or increased during training in cooling despite positive therapeutic expectations. The results of this study indicate that finger temperature warming, without autogenic training, is effective in reducing migraine activity, independent of suggestion effects.

  8. Sensing and Force-Feedback Exoskeleton (SAFE) Robotic Glove.

    PubMed

    Ben-Tzvi, Pinhas; Ma, Zhou

    2015-11-01

    This paper presents the design, implementation and experimental validation of a novel robotic haptic exoskeleton device to measure the user's hand motion and assist hand motion while remaining portable and lightweight. The device consists of a five-finger mechanism actuated with miniature DC motors through antagonistically routed cables at each finger, which act as both active and passive force actuators. The SAFE Glove is a wireless and self-contained mechatronic system that mounts over the dorsum of a bare hand and provides haptic force feedback to each finger. The glove is adaptable to a wide variety of finger sizes without constraining the range of motion. This makes it possible to accurately and comfortably track the complex motion of the finger and thumb joints associated with common movements of hand functions, including grip and release patterns. The glove can be wirelessly linked to a computer for displaying and recording the hand status through 3D Graphical User Interface (GUI) in real-time. The experimental results demonstrate that the SAFE Glove is capable of reliably modeling hand kinematics, measuring finger motion and assisting hand grasping motion. Simulation and experimental results show the potential of the proposed system in rehabilitation therapy and virtual reality applications.

  9. The biometric recognition on contactless multi-spectrum finger images

    NASA Astrophysics Data System (ADS)

    Kang, Wenxiong; Chen, Xiaopeng; Wu, Qiuxia

    2015-01-01

    This paper presents a novel multimodal biometric system based on contactless multi-spectrum finger images, which aims to deal with the limitations of unimodal biometrics. The chief merits of the system are the richness of the permissible texture and the ease of data access. We constructed a multi-spectrum instrument to simultaneously acquire three different types of biometrics from a finger: contactless fingerprint, finger vein, and knuckleprint. On the basis of the samples with these characteristics, a moderate database was built for the evaluation of our system. Considering the real-time requirements and the respective characteristics of the three biometrics, the block local binary patterns algorithm was used to extract features and match for the fingerprints and finger veins, while the Oriented FAST and Rotated BRIEF algorithm was applied for knuckleprints. Finally, score-level fusion was performed on the matching results from the aforementioned three types of biometrics. The experiments showed that our proposed multimodal biometric recognition system achieves an equal error rate of 0.109%, which is 88.9%, 94.6%, and 89.7% lower than the individual fingerprint, knuckleprint, and finger vein recognitions, respectively. Nevertheless, our proposed system also satisfies the real-time requirements of the applications.

  10. Convection and reaction in a diffusive boundary layer in a porous medium: nonlinear dynamics.

    PubMed

    Andres, Jeanne Therese H; Cardoso, Silvana S S

    2012-09-01

    We study numerically the nonlinear interactions between chemical reaction and convective fingering in a diffusive boundary layer in a porous medium. The reaction enhances stability by consuming a solute that is unstably distributed in a gravitational field. We show that chemical reaction profoundly changes the dynamics of the system, by introducing a steady state, shortening the evolution time, and altering the spatial patterns of velocity and concentration of solute. In the presence of weak reaction, finger growth and merger occur effectively, driving strong convective currents in a thick layer of solute. However, as the reaction becomes stronger, finger growth is inhibited, tip-splitting is enhanced and the layer of solute becomes much thinner. Convection enhances the mass flux of solute consumed by reaction in the boundary layer but has a diminishing effect as reaction strength increases. This nonlinear behavior has striking differences to the density fingering of traveling reaction fronts, for which stronger chemical kinetics result in more effective finger merger owing to an increase in the speed of the front. In a boundary layer, a strong stabilizing effect of reaction can maintain a long-term state of convection in isolated fingers of wavelength comparable to that at onset of instability.

  11. The effect of adding active flexion to modified Kleinert regime on outcomes for zone 1 to 3 flexor tendon repairs. A prospective randomized trial.

    PubMed

    Rigó, István Zoltán; Haugstvedt, Jan-Ragnar; Røkkum, Magne

    2017-11-01

    In a prospective randomized study, we studied whether adding active flexion to a modified Kleinert regime changed outcomes of flexor tendon repairs in zone 1, 2 and 3 in 73 fingers (53 patients). Evaluation included active range of finger motion, grip and pinch strengths. Twelve months after surgery, the increase in range of active finger motion after adding active flexion was insignificant compared with that with the modified Kleinert regime. According to the Strickland criteria, 20 out of 29 fingers had excellent or good recovery after adding active flexion, as did 28 out of 34 fingers with the modified Kleinert regime; we could not detect significant improvement of the good and excellent rate. At 6 months, the pinch strength was significantly higher with the addition of active flexion. We failed to find that adding active finger flexion to the modified Kleinert regime improves the overall long-term results of repairs in zone 1 to 3, though recovery appeared faster, and the good and excellent recovery of zone 2 repairs was 17% greater with the active flexion protocol. I.

  12. Aging and Haptic-Visual Solid Shape Matching.

    PubMed

    Norman, J Farley; Adkins, Olivia C; Dowell, Catherine J; Hoyng, Stevie C; Gilliam, Ashley N; Pedersen, Lauren E

    2017-08-01

    A total of 36 younger (mean age = 21.3 years) and older adults (mean age = 73.8 years) haptically explored plastic copies of naturally shaped objects (bell peppers, Capsicum annuum) one at a time for 7 s each. The participants' task was to then choose which of 12 concurrently visible objects had the same solid shape as the one they felt. The younger and older participants explored the object shapes using either one, three, or five fingers (there were six participants for each combination of number of fingers and age group). The outcome was different from that of previous research conducted with manmade objects. Unlike Jansson and Monaci (2006) , we found that for most objects, our participants' performance was unaffected by variations in the number of fingers used for haptic exploration. While there was no significant overall effect of the number of fingers, there was a significant main effect of age. The younger adults' shape matching performance was 48.6% higher than that of the older adults. When perceiving naturally shaped objects such as bell peppers, it appears that the usage of a single finger can be as effective as haptic exploration with a whole complement of five fingers.

  13. Fractal feature of sEMG from Flexor digitorum superficialis muscle correlated with levels of contraction during low-level finger flexions.

    PubMed

    Arjunan, Sridhar P; Kumar, Dinesh K; Naik, Ganesh R

    2010-01-01

    This research paper reports an experimental study on identification of the changes in fractal properties of surface Electromyogram (sEMG) with the changes in the force levels during low-level finger flexions. In the previous study, the authors have identified a novel fractal feature, Maximum fractal length (MFL) as a measure of strength of low-level contractions and has used this feature to identify various wrist and finger movements. This study has tested the relationship between the MFL and force of contraction. The results suggest that changes in MFL is correlated with the changes in contraction levels (20%, 50% and 80% maximum voluntary contraction (MVC)) during low-level muscle activation such as finger flexions. From the statistical analysis and by visualisation using box-plot, it is observed that MFL (p ≈ 0.001) is a more correlated to force of contraction compared to RMS (p≈0.05), even when the muscle contraction is less than 50% MVC during low-level finger flexions. This work has established that this fractal feature will be useful in providing information about changes in levels of force during low-level finger movements for prosthetic control or human computer interface.

  14. Advanced Technologies for Touchless Fingerprint Recognition

    NASA Astrophysics Data System (ADS)

    Parziale, Giuseppe; Chen, Yi

    A fingerprint capture consists of touching or rolling a finger onto a rigid sensing surface. During this act, the elastic skin of the finger deforms. The quantity and direction of the pressure applied by the user, the skin conditions, and the projection of an irregular 3D object (the finger) onto a 2D flat plane introduce distortions, noise, and inconsistencies on the captured fingerprint image. Due to these negative effects, the representation of the same fingerprint changes every time the finger is placed on the sensor platen, increasing the complexity of the fingerprint matching and representing a negative influence on the system performance. Recently, a new approach to capture fingerprints has been proposed. This approach, referred to as touchless or contactless fingerprinting, tries to overcome the above-cited problems. Because of the lack of contact between the finger and any rigid surface, the skin does not deform during the capture and the repeatability of the measure is quiet ensured. However, this technology introduces new challenges. Finger positioning, illumination, image contrast adjustment, data format compatibility, and user convenience are key in the design and development of touchless fingerprint systems. In addition, vulnerability to spoofing attacks of some touchless fingerprint systems must be addressed.

  15. Prediction of fingering in porous media

    NASA Astrophysics Data System (ADS)

    Wang, Zhi; Feyen, Jan; Elrick, David E.

    1998-09-01

    Immiscible displacement, involving two fluids in a porous medium, can be unstable and fingered under certain conditions. In this paper, the original linear instability criterion of Chuoke et al. [1959] is generalized, considering wettability of two immiscible fluids to the porous medium. This is then used to predict 24 specific flow and porous medium conditions for the onset of wetting front instability in the subsurface. Wetting front instability is shown to be a function of the driving fluid wettability to the medium, differences in density and viscosity of the fluids, the magnitude of the interfacial tension, and the direction of flow with respect to gravity. Scenarios of water and nonaqueous-phase liquid infiltration into the vadose zone are examined to predict preferential flow and contamination of groundwater. The mechanisms of finger formation, propagation, and persistence in the vadose zone are reviewed, and the existing equations for calculating the size, the number and velocity of fingers are simplified for field applications. The analyses indicate that fingers initiate and propagate according to spatial and temporal distribution of the dynamic breakthrough (water- or air-entry) pressures in the porous medium. The predicted finger size and velocity are in close agreement with the experimental results.

  16. Quantifying palpation techniques in relation to performance in a clinical prostate exam.

    PubMed

    Wang, Ninghuan; Gerling, Gregory J; Childress, Reba Moyer; Martin, Marcus L

    2010-07-01

    This paper seeks to quantify finger palpation techniques in the prostate clinical exam, determine their relationship with performance in detecting abnormalities, and differentiate the tendencies of nurse practitioner students and resident physicians. One issue with the digital rectal examination (DRE) is that performance in detecting abnormalities varies greatly and agreement between examiners is low. The utilization of particular palpation techniques may be one way to improve clinician ability. Based on past qualitative instruction, this paper algorithmically defines a set of palpation techniques for the DRE, i.e., global finger movement (GFM), local finger movement (LFM), and average intentional finger pressure, and utilizes a custom-built simulator to analyze finger movements in an experiment with two groups: 18 nurse practitioner students and 16 resident physicians. Although technique utilization varied, some elements clearly impacted performance. For example, those utilizing the LFM of vibration were significantly better at detecting abnormalities. Also, the V GFM led to greater success, but finger pressure played a lesser role. Interestingly, while the residents were clearly the superior performers, their techniques differed only subtly from the students. In summary, the quantified palpation techniques appear to account for examination ability at some level, but not entirely for differences between groups.

  17. Transfer of supinator motor branches to the posterior interosseous nerve in C7-T1 brachial plexus palsy.

    PubMed

    Bertelli, Jayme Augusto; Ghizoni, Marcos Flavio

    2010-07-01

    In C7-T1 palsies of the brachial plexus, shoulder and elbow function are preserved, but finger motion is absent. Finger flexion has been reconstructed by tendon or nerve transfers. Finger extension has been restored ineffectively by attaching the extensor tendons to the distal aspect of the dorsal radius (termed tenodesis) or by tendon transfers. In these palsies, supinator muscle function is preserved, because innervation stems from the C-6 root. The feasibility of transferring supinator branches to the posterior interosseous nerve has been documented in a previous anatomical study. In this paper, the authors report the clinical results of supinator motor nerve transfer to the posterior interosseous nerve in 4 patients with a C7-T1 root lesion. Four adult patients with C7-T1 root lesions underwent surgery between 5 and 7 months postinjury. The patients had preserved motion of the shoulder, elbow, and wrist, but they had complete palsy of finger motion. They underwent finger flexion reconstruction via transfer of the brachialis muscle, and finger and thumb extension were restored by transferring the supinator motor branches to the posterior interosseous nerve. This nerve transfer was performed through an incision over the proximal third of the radius. Dissection was carried out between the extensor carpi radialis brevis and the extensor digitorum communis. The patients were followed up as per regular protocol and underwent a final evaluation 12 months after surgery. To document the extent of recovery, the authors assessed the degree of active metacarpophalangeal joint extension of the long fingers. The thumb span was evaluated by measuring the distance between the thumb pulp and the lateral aspect of the index finger. Surgery to transfer the supinator motor branches to the posterior interosseous nerve was straightforward. Twelve months after surgery, all patients were capable of opening their hand and could fully extend their metacarpophalangeal joints. The distance of thumb abduction improved from 0 to 5 cm from the lateral aspect of the index finger. Transferring supinator motor nerves directly to the posterior interosseous nerve is effective in at least partially restoring thumb and finger extension in patients with lower-type injuries of the brachial plexus.

  18. Cheiloscopy and dactyloscopy: Do they dictate personality patterns?

    PubMed Central

    Abidullah, Mohammed; Kumar, M. Naveen; Bhorgonde, Kavita D.; Reddy, D. Shyam Prasad

    2015-01-01

    Context: Cheiloscopy and dactyloscopy, both are well-established forensic tools used in individual identification in any scenario be it a crime scene or civil cause. Like finger prints, lip prints are unique and distinguishable for every individual. But their relationship to personality types has not been established excepting the hypothesis stating that finger prints could explain these personality patterns. Aims: The study was aimed to record and correlate the lip and finger prints with that of character/personality of a person. Settings and Design: The lip and finger prints and character of a person were recorded and the data obtained was subjected for statistical analysis, especially for Pearson's Chi-square test and correlation/association between the groups was also studied. Materials and Methods: The study sample comprised of 200 subjects, 100 males and 100 females, aged between 18 and 30 years. For recording lip prints, brown/pink-colored lipstick was applied on the lips and the subjects were asked to spread uniformly over the lips. Lip prints were traced in the normal rest position on a plain white bond paper. For recording the finger prints, imprints of the fingers were taken on a plain white bond paper using ink pad. The collected prints were visualized using magnifying lens. To record the character of person, a pro forma manual for multivariable personality inventory by Dr. BC Muthayya was used. Statistical Analysis Used: Data obtained was subjected for statistical analysis, especially for Pearson's Chi-square test and correlation/association between the groups was also studied. Results: In males, predominant lip pattern recorded was Type I with whorls-type finger pattern and the character being ego ideal, pessimism, introvert, and dogmatic; whereas in females, predominant lip pattern recorded was Type II with loops-type finger pattern and the character being neurotic, need achievers, and dominant. Conclusion: Many studies on lip pattern, finger pattern, palatal rugae, etc., for individual identification and gender determination exist, but correlative studies are scanty. This is the first study done on correlating patterns, that is, lip and finger pattern with the character of a person. With this study we conclude that this correlation can be used as an adjunct in the investigatory process in forensic sciences. PMID:26005299

  19. [Hand and finger anomalous developmental coordination to write in children with attention deficit/hyperactivity syndrome].

    PubMed

    Pascual-Castroviejo, I; Lobo-Llorente, A

    To present a developmental coordination disorder in children with attention deficit/hyperactivity syndrome (ADHS) characterized by anomalous handwriting posture of hands and fingers. Forty-five children who presented with ADHS were studied (39 males and 6 females) with ages ranging from 6 to 16 years (average 10.8 years) and an analysis of the position of the hands and fingers during handwriting was made within the context of a complete neurological evaluation. Only 2 of the 6 hyperactive patients showed a discrete anomalous posture of the fingers, with normality in the other four patients. Seventeen of the 25 children (68%) with ADHS combined type showed poor posture of the fingers when writing. Among the 14 children with ADHS attention deficit type, 8 had abnormal posture when using a pencil, and 4 had shown the problem several years before consulting, and the problem had disappeared after local orthopedic treatment. All 4 left-handed children (3 females and 1 male) presented abnormal posture of the fingers when writing. Evaluation of the anomalous posture of the fingers when writing of patients with ADHS is a test that we commonly use because it is easy to do, the patients collaborate very well to do it and uncovers very early the developmental coordination disorder. The anomalous posture is associated with other coordination disorders and problems of muscular tone such as splay-foot, genu recurvatum, problems with jumping, walking on one foot, etc. in most patients.

  20. Finger forces in fastball baseball pitching.

    PubMed

    Kinoshita, Hiroshi; Obata, Satoshi; Nasu, Daiki; Kadota, Koji; Matsuo, Tomoyuki; Fleisig, Glenn S

    2017-08-01

    Forces imparted by the fingers onto a baseball are the final, critical aspects for pitching, however these forces have not been quantified previously as no biomechanical technology was available. In this study, an instrumented baseball was developed for direct measurement of ball reaction force by individual fingers and used to provide fundamental information on the forces during a fastball pitch. A tri-axial force transducer with a cable having an easily-detachable connector were installed in an official baseball. Data were collected from 11 pitchers who placed the fingertip of their index, middle, ring, or thumb on the transducer, and threw four-seam fastballs to a target cage from a flat mound. For the index and middle fingers, resultant ball reaction force exhibited a bimodal pattern with initial and second peaks at 38-39ms and 6-7ms before ball release, and their amplitudes were around 97N each. The ring finger and thumb produced single-peak forces of approximately 50 and 83N, respectively. Shear forces for the index and middle fingers formed distinct peak at 4-5ms before release, and the peaks summed to 102N; a kinetic source for backspin on the ball. An additional experiment with submaximal pitching effort showed a linear relationship of peak forces with ball velocity. The peak ball reaction force for fastballs exceeded 80% of maximum finger strength measured, suggesting that strengthening of the distal muscles is important both for enhancing performance and for avoiding injuries. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Identification of the ``a'' Genome of Finger Millet Using Chloroplast DNA

    PubMed Central

    Hilu, K. W.

    1988-01-01

    Finger millet (Eleusine corocana subsp. coracana), an important cereal in East Africa and India, is a tetraploid species with unknown genomic components. A recent cytogenetic study confirmed the direct origin of this millet from the tetraploid E. coracana subsp. africana but questioned Eleusine indica as a genomic donor. Chloroplast (ct) DNA sequence analysis using restriction fragment pattern was used to examine the phylogenetic relationships between E. coracana subsp. coracana (domesticated finger millet), E. coracana subspecies africana (wild finger millet), and E. indica. Eleusine tristachya was included since it is the only other annual diploid species in the genus with a basic chromosome number of x = 9 like finger millet. Eight of the ten restriction endonucleases used had 16 to over 30 restriction sites per genome and were informative. E. coracana subsp. coracana and subsp. africana and E. indica were identical in all the restriction sites surveyed, while the ct genome of E. tristachya differed consistently by at least one mutational event for each restriction enzyme surveyed. This random survey of the ct genomes of these species points out E. indica as one of the genome donors (maternal genome donor) of domesticated finger millet contrary to a previous cytogenetic study. The data also substantiate E. coracana subsp. africana as the progenitor of domesticated finger millet. The disparity between the cytogenetic and the molecular approaches is discussed in light of the problems associated with chromosome pairing and polyploidy. PMID:8608927

  2. Frequency weightings based on biodynamics of fingers-hand-arm system.

    PubMed

    Dong, Ren G; Welcome, Daniel E; Wu, John Z

    2005-07-01

    The frequency weighting for assessing hand-transmitted vibration exposure is critical to obtaining a true dose-response relationship. Any valid weighting must have a solid theoretical foundation. The objectives of this study are to examine the biodynamic foundation for assessing the vibration exposure and to develop a set of biodynamic methods to formulate the frequency weightings for different anatomical locations of the fingers-hand-arm system. The vibration transmissibility measured on the fingers, hand, wrist, elbow, shoulder, and head was used to define the transmitted acceleration-based (TAB) frequency weighting. The apparent masses measured at the fingers and the palm of the hand were used to construct the biodynamic force-based (BFB) weightings. These weightings were compared with the ISO weighting specified in ISO 5349-1 (2001). The results of this study suggest that the frequency weightings for the vibration-induced problems at different anatomical locations of the hand-arm system can be basically divided into three groups: (a) the weighting for the fingers and hand, (b) the weighting for the wrist, elbow, and shoulder, and (c) the weighting for the head. The ISO weighting is highly correlated with the weighting for the second group but not with the first and third groups. The TAB and BFB finger weightings are quite different at frequencies lower than 100 Hz, but they show similar trends at higher frequencies. Both TAB and BFB finger weightings at frequencies higher than 20 Hz are greater than the ISO weighting.

  3. Cross-genera transferability of rice and finger millet genomic SSRs to barnyard millet (Echinochloa spp.).

    PubMed

    Kalyana Babu, B; Sood, Salej; Kumar, Dinesh; Joshi, Anjeli; Pattanayak, A; Kant, Lakshmi; Upadhyaya, H D

    2018-02-01

    Barnyard millet ( Echinochloa spp.) is an important crop from nutritional point of view, nevertheless, the genetic information is very scarce. In the present investigation, rice and finger millet genomic SSRs were used for assessing cross transferability, identification of polymorphic markers, syntenic regions, genetic diversity and population structure analysis of barnyard millet genotypes. We observed 100% cross transferability for finger millet SSRs, of which 91% were polymorphic, while 71% of rice markers were cross transferable with 48% polymorphic out of them. Twenty-nine and sixteen highly polymorphic finger millet and rice SSRs yielded a mean of 4.3 and 3.38 alleles per locus in barnyard millet genotypes, respectively. The PIC values varied from 0.27 to 0.73 at an average of 0.54 for finger millet SSRs, whereas it was from 0.15 to 0.67 at an average of 0.44 for rice SSRs. High synteny was observed for markers related to panicle length, yield-related traits, spikelet fertility, plant height, root traits, leaf senescence, blast and brown plant hopper resistance. Although the rice SSRs located on chromosome 10 followed by chromosome 6 and 11 were found to be more transferable to barnyard millet, the finger millet SSRs were more polymorphic and transferable to barnyard millet genotypes. These SSR data of finger millet and rice individually as well as combined together grouped the 11 barnyard millet genotypes into 2 major clusters. The results of population structure analysis were similar to cluster analysis.

  4. Tactile spatial resolution in blind braille readers.

    PubMed

    Van Boven, R W; Hamilton, R H; Kauffman, T; Keenan, J P; Pascual-Leone, A

    2000-06-27

    To determine if blind people have heightened tactile spatial acuity. Recently, studies using magnetic source imaging and somatosensory evoked potentials have shown that the cortical representation of the reading fingers of blind Braille readers is expanded compared to that of fingers of sighted subjects. Furthermore, the visual cortex is activated during certain tactile tasks in blind subjects but not sighted subjects. The authors hypothesized that the expanded cortical representation of fingers used in Braille reading may reflect an enhanced fidelity in the neural transmission of spatial details of a stimulus. If so, the quantitative limit of spatial acuity would be superior in blind people. The authors employed a grating orientation discrimination task in which threshold performance is accounted for by the spatial resolution limits of the neural image evoked by a stimulus. The authors quantified the psychophysical limits of spatial acuity at the middle and index fingers of 15 blind Braille readers and 15 sighted control subjects. The mean grating orientation threshold was significantly (p = 0.03) lower in the blind group (1.04 mm) compared to the sighted group (1.46 mm). The self-reported dominant reading finger in blind subjects had a mean grating orientation threshold of 0.80 mm, which was significantly better than other fingers tested. Thresholds at non-Braille reading fingers in blind subjects averaged 1.12 mm, which were also superior to sighted subjects' performances. Superior tactile spatial acuity in blind Braille readers may represent an adaptive, behavioral correlate of cortical plasticity.

  5. Quick-connect fasteners for assembling devices in space

    NASA Technical Reports Server (NTRS)

    Evenson, Erik E. (Inventor); Wesselski, Clarence J. (Inventor); Ruiz, Steve C. (Inventor)

    1993-01-01

    A quick-connect fastener of a relatively-simple straightforward design is arranged with a tubular body adapted to be engaged against an attachment fitting in coincidental alignment with an opening in that fitting. A tubular collet having flexible fingers projecting from its forward end is arranged in the fastener body to be shifted forwardly by an elongated expander member coaxially arranged within the tubular collet for advancing the collet fingers into the opening in the attachment fitting. Biasing means are arranged between the elongated expander member and a rotatable actuator which is threadedly mounted within the tubular collet so as to be rotated for urging the expander member into engagement with the collet fingers. A first coupling member is arranged on the rotatable actuator to be accessible from outside of the fastener so that a second coupling member on the distal end of a flexible shaft can be introduced into the fastener body and coupled to the first coupling member to enable a typical actuating tool coupled to the shaft outside of the fastener body to be operated for advancing the outwardly-enlarged ends of the collet fingers into the opening in the attachment fitting and thereafter rotating the actuator member to expand the fingers within the opening for releasably latching the fastener to that attachment fitting. Upon expansion of the collet fingers, the biasing means impose a biasing force on the expander to releasably retain the fingers in their latching positions.

  6. Prospective study of periostitis and finger clubbing in primary biliary cirrhosis and other forms of chronic liver disease.

    PubMed Central

    Epstein, O; Dick, R; Sherlock, S

    1981-01-01

    The association of finger clubbing and periostitis has been reported in primary biliary cirrhosis and, more rarely, in other forms of chronic liver disease. The prevalence of periostitis and its relationship to finger clubbing is unknown. In this prospective study, we have determined the prevalence of periostitis and finger clubbing in 74 patients with primary biliary cirrhosis and 54 with other forms of chronic liver disease. Clubbing was present in 24% of patients with primary biliary cirrhosis, 29% with HBsAg negative chronic active hepatitis, and 23% in the group of miscellaneous liver diseases. Symmetrical periostitis affecting the tibiae and fibulae occurred in 35% of patients with primary biliary cirrhosis, 29% with chronic, active hepatitis and 40% of patients in the miscellaneous group. The distal radii and ulnae were affected in only eight patients (6%). In primary biliary cirrhosis, the presence of finger clubbing was strongly associated with periostitis (P less than 0.01), but this association was uncommon in other forms of chronic liver disease. In all forms of chronic liver disease periostitis commonly occurs in the absence of finger clubbing. Marked tenderness over the distal leg bones is a reliable sign of underlying periostitis, but this sign is present in only a third of affected patients. This study indicates that periostitis affecting the lower leg bones is common in patients with chronic liver disease, and its presence should be sought whether or not the patient has finger clubbing. Images Fig. 2 PMID:7227854

  7. Development of a Compact Wireless Laplacian Electrode Module for Electromyograms and Its Human Interface Applications

    PubMed Central

    Fukuoka, Yutaka; Miyazawa, Kenji; Mori, Hiroki; Miyagi, Manabi; Nishida, Masafumi; Horiuchi, Yasuo; Ichikawa, Akira; Hoshino, Hiroshi; Noshiro, Makoto; Ueno, Akinori

    2013-01-01

    In this study, we developed a compact wireless Laplacian electrode module for electromyograms (EMGs). One of the advantages of the Laplacian electrode configuration is that EMGs obtained with it are expected to be sensitive to the firing of the muscle directly beneath the measurement site. The performance of the developed electrode module was investigated in two human interface applications: character-input interface and detection of finger movement during finger Braille typing. In the former application, the electrode module was combined with an EMG-mouse click converter circuit. In the latter, four electrode modules were used for detection of finger movements during finger Braille typing. Investigation on the character-input interface indicated that characters could be input stably by contraction of (a) the masseter, (b) trapezius, (c) anterior tibialis and (d) flexor carpi ulnaris muscles. This wide applicability is desirable when the interface is applied to persons with physical disabilities because the disability differs one to another. The investigation also demonstrated that the electrode module can work properly without any skin preparation. Finger movement detection experiments showed that each finger movement was more clearly detectable when comparing to EMGs recorded with conventional electrodes, suggesting that the Laplacian electrode module is more suitable for detecting the timing of finger movement during typing. This could be because the Laplacian configuration enables us to record EMGs just beneath the electrode. These results demonstrate the advantages of the Laplacian electrode module. PMID:23396194

  8. Directionality analysis on functional magnetic resonance imaging during motor task using Granger causality.

    PubMed

    Anwar, A R; Muthalib, M; Perrey, S; Galka, A; Granert, O; Wolff, S; Deuschl, G; Raethjen, J; Heute, U; Muthuraman, M

    2012-01-01

    Directionality analysis of signals originating from different parts of brain during motor tasks has gained a lot of interest. Since brain activity can be recorded over time, methods of time series analysis can be applied to medical time series as well. Granger Causality is a method to find a causal relationship between time series. Such causality can be referred to as a directional connection and is not necessarily bidirectional. The aim of this study is to differentiate between different motor tasks on the basis of activation maps and also to understand the nature of connections present between different parts of the brain. In this paper, three different motor tasks (finger tapping, simple finger sequencing, and complex finger sequencing) are analyzed. Time series for each task were extracted from functional magnetic resonance imaging (fMRI) data, which have a very good spatial resolution and can look into the sub-cortical regions of the brain. Activation maps based on fMRI images show that, in case of complex finger sequencing, most parts of the brain are active, unlike finger tapping during which only limited regions show activity. Directionality analysis on time series extracted from contralateral motor cortex (CMC), supplementary motor area (SMA), and cerebellum (CER) show bidirectional connections between these parts of the brain. In case of simple finger sequencing and complex finger sequencing, the strongest connections originate from SMA and CMC, while connections originating from CER in either direction are the weakest ones in magnitude during all paradigms.

  9. Delayed recovery of the affected finger extensors at chronic stage in a stroke patient: A case report.

    PubMed

    Jang, Sung Ho; Lee, Han Do

    2017-10-01

    A 33-year-old male presented with complete weakness of the right extremities due to corona radiata infarct. The main concerns of the patient is recovery of hand function especially related to finger extension. Right corona radiata infarct. He underwent physical therapy and occupational therapy at the outpatient clinic of the rehabilitation department of the same university hospital until 2 years after onset. In addition, he underwent neuromuscular electrical stimulation for the right finger extensors continuously until 4 years after onset. At 6 months after onset, the weakness of his right side recovered to subnormal state except for the right finger extensors which were completely weak. At 1.5 years after onset, the right finger extensors began to show slow and continuous recovery. At 4 years after onset, the patient showed motor recovery in the right finger extensors to the extent that he was able to move against gravity. Discontinuation of the left corticospinal tract was observed on 2-month diffusion tensor tractography (DTT); however, the integrity of this discontinuation had recovered to the primary motor cortex on 4-year DTT. On 2-month transcranial magnetic stimulation (TMS), no motor-evoked potential was evoked; in contrast, motor-evoked potentials were obtained at the right-hand muscle on 4-year TMS study. We demonstrated unusual delayed and long-term recovery of the affected finger extensors in a patient with corona radiata infarct using DTT and TMS.

  10. Autonomic Mechanisms Associated with Heart Rate and Vasoconstrictor Reserves

    DTIC Science & Technology

    2011-11-15

    hemodynamic decompensation (i.e., severe hypo- tension and pre-syncope) has revealed that subjects with high tolerance (HT) to reduced central blood ...electrical potentials, and an infrared finger photoplethysmograph (Finometer Blood Pressure Moni- tor, TNO-TPD Biomedical Instrumentation, Amsterdam...The Netherlands) to record beat-by-beat finger arterial pressure . The Finometer blood pressure cuff was placed on the middle finger of the left

  11. Continuous and simultaneous estimation of finger kinematics using inputs from an EMG-to-muscle activation model.

    PubMed

    Ngeo, Jimson G; Tamei, Tomoya; Shibata, Tomohiro

    2014-08-14

    Surface electromyography (EMG) signals are often used in many robot and rehabilitation applications because these reflect motor intentions of users very well. However, very few studies have focused on the accurate and proportional control of the human hand using EMG signals. Many have focused on discrete gesture classification and some have encountered inherent problems such as electro-mechanical delays (EMD). Here, we present a new method for estimating simultaneous and multiple finger kinematics from multi-channel surface EMG signals. In this study, surface EMG signals from the forearm and finger kinematic data were extracted from ten able-bodied subjects while they were tasked to do individual and simultaneous multiple finger flexion and extension movements in free space. Instead of using traditional time-domain features of EMG, an EMG-to-Muscle Activation model that parameterizes EMD was used and shown to give better estimation performance. A fast feed forward artificial neural network (ANN) and a nonparametric Gaussian Process (GP) regressor were both used and evaluated to estimate complex finger kinematics, with the latter rarely used in the other related literature. The estimation accuracies, in terms of mean correlation coefficient, were 0.85 ± 0.07, 0.78 ± 0.06 and 0.73 ± 0.04 for the metacarpophalangeal (MCP), proximal interphalangeal (PIP) and the distal interphalangeal (DIP) finger joint DOFs, respectively. The mean root-mean-square error in each individual DOF ranged from 5 to 15%. We show that estimation improved using the proposed muscle activation inputs compared to other features, and that using GP regression gave better estimation results when using fewer training samples. The proposed method provides a viable means of capturing the general trend of finger movements and shows a good way of estimating finger joint kinematics using a muscle activation model that parameterizes EMD. The results from this study demonstrates a potential control strategy based on EMG that can be applied for simultaneous and continuous control of multiple DOF(s) devices such as robotic hand/finger prostheses or exoskeletons.

  12. Adhesive taping vs. daily manual muscle stretching and splinting after botulinum toxin type A injection for wrist and fingers spastic overactivity in stroke patients: a randomized controlled trial.

    PubMed

    Santamato, Andrea; Micello, Maria Francesca; Panza, Francesco; Fortunato, Francesca; Picelli, Alessandro; Smania, Nicola; Logroscino, Giancarlo; Fiore, Pietro; Ranieri, Maurizio

    2015-01-01

    To compare the effectiveness of two procedures increasing the botulinum toxin type A effect for wrist and finger flexor spasticity after stroke. A single-blind randomized trial. Seventy patients with upper limb post-stroke spasticity. Adults with wrist and finger flexor muscles spasticity after stroke were submitted to botulinum toxin type A therapy. After the treatment, the subjects injected were randomly divided into two groups and submitted to adhesive taping (Group A) or daily muscle manual stretching, passive articular mobilization of wrist and fingers, and palmar splint (Group B) for 10 days. We measured spasticity with Modified Ashworth Scale, related disability with Disability Assessment Scale, and fingers position at rest. The measurements were done at baseline, after two weeks, and after one month from the treatment session. After two weeks, subjects in Group A reported a significantly greater decrease in spasticity scores (Modified Ashworth Scale fingers: mean (standard deviation) 1.3±0.6 vs. 2.1±0.6; Modified Ashworth Scale wrist: 1.7 ±0.6 vs. 2.3 ±0.8), and after one month in spasticity and disability scores (Modified Ashworth Scale fingers: mean (standard deviation) 1.9 ±0.7 vs. 2.5 ±0.6; Modified Ashworth Scale wrist: 2.0 ±0.7 vs. 2.6 ±0.6; Disability Assessment Scale: 1.6 ±0.7 vs. 2.1 ±0.7) compared with Group B subjects. Subjects in Group A reported also a significantly improved fingers position at rest compared with Group B subjects after two weeks (2.8 ±0.9 vs. 2.1 ±0.7) and one month (2.3 ±0.7 vs. 1.5 ±0.6). Adhesive taping of wrist and finger flexor muscles appeared to enhance the effect of botulinum toxin type A therapy more than daily manual muscle stretching combined with passive articular mobilization and palmar splint. © The Author(s) 2014.

  13. An EMG Interface for the Control of Motion and Compliance of a Supernumerary Robotic Finger

    PubMed Central

    Hussain, Irfan; Spagnoletti, Giovanni; Salvietti, Gionata; Prattichizzo, Domenico

    2016-01-01

    In this paper, we propose a novel electromyographic (EMG) control interface to control motion and joints compliance of a supernumerary robotic finger. The supernumerary robotic fingers are a recently introduced class of wearable robotics that provides users additional robotic limbs in order to compensate or augment the existing abilities of natural limbs without substituting them. Since supernumerary robotic fingers are supposed to closely interact and perform actions in synergy with the human limbs, the control principles of extra finger should have similar behavior as human’s ones including the ability of regulating the compliance. So that, it is important to propose a control interface and to consider the actuators and sensing capabilities of the robotic extra finger compatible to implement stiffness regulation control techniques. We propose EMG interface and a control approach to regulate the compliance of the device through servo actuators. In particular, we use a commercial EMG armband for gesture recognition to be associated with the motion control of the robotic device and surface one channel EMG electrodes interface to regulate the compliance of the robotic device. We also present an updated version of a robotic extra finger where the adduction/abduction motion is realized through ball bearing and spur gears mechanism. We have validated the proposed interface with two sets of experiments related to compensation and augmentation. In the first set of experiments, different bimanual tasks have been performed with the help of the robotic device and simulating a paretic hand since this novel wearable system can be used to compensate the missing grasping abilities in chronic stroke patients. In the second set, the robotic extra finger is used to enlarge the workspace and manipulation capability of healthy hands. In both sets, the same EMG control interface has been used. The obtained results demonstrate that the proposed control interface is intuitive and can successfully be used, not only to control the motion of a supernumerary robotic finger but also to regulate its compliance. The proposed approach can be exploited also for the control of different wearable devices that has to actively cooperate with the human limbs. PMID:27891088

  14. Evolution and Growth Competition of Salt Fingers in Saline Lake with Slight Wind Shear

    NASA Astrophysics Data System (ADS)

    Yang, Ray-Yeng; Hwung, Hwung-Hweng; Shugan, Igor

    2010-05-01

    Since the discover of double-diffusive convection by Stommel, Arons & Blanchard (1956), 'evidence has accumulated for the widespread presence of double-diffusion throughout the ocean' and for its 'significant effects on global water-mass structure and the thermohaline convection' (Schmitt, 1998). The salt-fingering form of double-diffusion has particularly attracted interest because of salt-finger convection being now widely recognized as an important mechanism for mixing heat and salt both vertically and laterally in the ocean and saline lake. In oceanographic situations or saline lake where salt fingers may be an important mechanism for the transport of heat and salt in the vertical, velocity shears may also be present. Salt finger convection is analogous to Bénard convection in that the kinetic energy of the motions is obtained from the potential energy stored in the unstable distribution of a stratifying component. On the basis of the thermal analogy it is of interest to discover whether salt fingers are converted into two-dimensional sheets by the wind shear, and how the vertical fluxes of heat and salt are changed by the wind shear. Salt finger convection under the effect of steady wind shear is theoretically examined in this paper. The evolution of developing in the presence of a vertical density gradient disturbance and the horizontal Couette flow is considered near the onset of salt fingers in the saline lake under a moderate rate of wind shear. We use velocity as the basic variable and solve the pressure Poisson equation in terms of the associated Green function. Growth competition between the longitudinal rolls (LR) and the transverse rolls (TR), whose axes are respectively in the direction parallel to and perpendicular to the Couette flow, is investigated by the weakly nonlinear analysis of coupled-mode equations. The results show that the TR mode is characterized in some range of the effective Rayleigh number, and that the stability is dominated by the LR mode in the system. KEY WORDS: evolution, saline lake, salt finger convection, wind shear, growth competition, longitudinal rolls, transverse rolls, coupled-mode equations.

  15. Sports Injury-Related Fingers and Thumb Deformity Due to Tendon or Ligament Rupture.

    PubMed

    Bai, Rong-Jie; Zhang, Hui-Bo; Zhan, Hui-Li; Qian, Zhan-Hua; Wang, Nai-Li; Liu, Yue; Li, Wen-Ting; Yin, Yu-Ming

    2018-05-05

    Hand injuries are very common in sports, such as skiing and ball sports. One of the major reasons causing hand and finger deformity is due to ligament and tendon injury. The aim of this study was to investigate if the high-resolution 3T magnetic resonance imaging (MRI) can demonstrate the complex anatomy of the fingers and thumb, especially the tendons and ligaments, and provide the accurate diagnosis of clinically important fingers and thumbs deformity due to ligamentous and tendinous injuries during sport activities. Sixteen fresh un-embalmed cadaveric hands were harvested from eight cadavers. A total of 20 healthy volunteers' hands and 44 patients with fingers or thumb deformity due to sports-related injuries were included in this study. All subjects had MR examination with T1-weighted images and proton density-weighted imaging with fat suppression (PD FS) in axial, coronal, and sagittal plane, respectively. Subsequently, all 16 cadaveric hands were sliced into 2-mm thick slab with a band saw (six in coronal plane, six in sagittal plane, and four in axial plane). The correlation of anatomic sections and the MRI characteristics of tendons of fingers and the ulnar collateral ligament (UCL) at the metacarpal phalangeal joint (MCPJ) of thumb between 20 healthy volunteers and 44 patients (confirmed by surgery) were analyzed. The normal ligaments and tendons in 16 cadaveric hands and 20 volunteers' hands showed uniform low-signal intensity on all the sequences of the MRI. Among 44 patients with tendinous and ligamentous injuries in the fingers or thumb, 12 cases with UCL injury at MCPJ of the thumb (Stener lesion = 8 and non-Stener lesion = 4), 6 cases with the central slip injury, 12 cases with terminal tendon injury, and 14 cases with flexor digitorum profundus injury. The ligaments and tendons disruption manifested as increased signal intensity and poor definition, discontinuity, and heterogeneous signal intensity of the involved ligaments and tendons. Sports injury-related fingers and thumb deformity are relatively common. MRI is an accurate method for evaluation of the anatomy and pathologic conditions of the fingers and thumb. It is a useful tool for accurate diagnosis of the sports-related ligaments and tendons injuries in hand.

  16. Coordinated turn-and-reach movements. II. Planning in an external frame of reference

    NASA Technical Reports Server (NTRS)

    Pigeon, Pascale; Bortolami, Simone B.; DiZio, Paul; Lackner, James R.

    2003-01-01

    The preceding study demonstrated that normal subjects compensate for the additional interaction torques generated when a reaching movement is made during voluntary trunk rotation. The present paper assesses the influence of trunk rotation on finger trajectories and on interjoint coordination and determines whether simultaneous turn-and-reach movements are most simply described relative to a trunk-based or an external reference frame. Subjects reached to targets requiring different extents of arm joint and trunk rotation at a natural pace and quickly in normal lighting and in total darkness. We first examined whether the larger interaction torques generated during rapid turn-and-reach movements perturb finger trajectories and interjoint coordination and whether visual feedback plays a role in compensating for these torques. These issues were addressed using generalized Procrustes analysis (GPA), which attempts to overlap a group of configurations (e.g., joint trajectories) through translations and rotations in multi-dimensional space. We first used GPA to identify the mean intrinsic patterns of finger and joint trajectories (i.e., their average shape irrespective of location and orientation variability in the external and joint workspaces) from turn-and-reach movements performed in each experimental condition and then calculated their curvatures. We then quantified the discrepancy between each finger or joint trajectory and the intrinsic pattern both after GPA was applied individually to trajectories from a pair of experimental conditions and after GPA was applied to the same trajectories pooled together. For several subjects, joint trajectories but not finger trajectories were more curved in fast than slow movements. The curvature of both joint and finger trajectories of turn-and-reach movements was relatively unaffected by the vision conditions. Pooling across speed conditions significantly increased the discrepancy between joint but not finger trajectories for most subjects, indicating that subjects used different patterns of interjoint coordination in slow and fast movements while nevertheless preserving the shape of their finger trajectory. Higher movement speeds did not disrupt the arm joint rotations despite the larger interaction torques generated. Rather, subjects used the redundant degrees of freedom of the arm/trunk system to achieve similar finger trajectories with differing joint configurations. We examined finger movement patterns and velocity profiles to determine the frame of reference in which turn-and-reach movements could be most simply described. Finger trajectories of turn-and-reach movements had much larger curvatures and their velocity profiles were less smooth and less bell-like in trunk-based coordinates than in external coordinates. Taken together, these results support the conclusion that turn-and-reach movements are controlled in an external frame of reference.

  17. Finger millet [Eleusine coracana (L.) Gaertn].

    PubMed

    Ceasar, Stanislaus Antony; Ignacimuthu, Savarimuthu

    2015-01-01

    Millets are the primary food source for millions of people in tropical regions of the world supplying mineral nutrition and protein. In this chapter, we describe an optimized protocol for the Agrobacterium-mediated transformation of finger millet variety GPU 45. Agrobacterium strain LBA4404 harboring plasmid pCAMBIA1301 which contains hygromycin phosphotransferase (hph) as selectable marker gene and β-glucuronidase (GUS) as reporter gene has been used. This protocol utilizes the shoot apex explants for the somatic embryogenesis and regeneration of finger millet after the transformation by Agrobacterium. Desiccation of explants during cocultivation helps for the better recovery of transgenic plants. This protocol is very useful for the efficient production of transgenic plants in finger millet through Agrobacterium-mediated transformation.

  18. Estimation of continuous multi-DOF finger joint kinematics from surface EMG using a multi-output Gaussian Process.

    PubMed

    Ngeo, Jimson; Tamei, Tomoya; Shibata, Tomohiro

    2014-01-01

    Surface electromyographic (EMG) signals have often been used in estimating upper and lower limb dynamics and kinematics for the purpose of controlling robotic devices such as robot prosthesis and finger exoskeletons. However, in estimating multiple and a high number of degrees-of-freedom (DOF) kinematics from EMG, output DOFs are usually estimated independently. In this study, we estimate finger joint kinematics from EMG signals using a multi-output convolved Gaussian Process (Multi-output Full GP) that considers dependencies between outputs. We show that estimation of finger joints from muscle activation inputs can be improved by using a regression model that considers inherent coupling or correlation within the hand and finger joints. We also provide a comparison of estimation performance between different regression methods, such as Artificial Neural Networks (ANN) which is used by many of the related studies. We show that using a multi-output GP gives improved estimation compared to multi-output ANN and even dedicated or independent regression models.

  19. A cortically-inspired model for inverse kinematics computation of a humanoid finger with mechanically coupled joints.

    PubMed

    Gentili, Rodolphe J; Oh, Hyuk; Kregling, Alissa V; Reggia, James A

    2016-05-19

    The human hand's versatility allows for robust and flexible grasping. To obtain such efficiency, many robotic hands include human biomechanical features such as fingers having their two last joints mechanically coupled. Although such coupling enables human-like grasping, controlling the inverse kinematics of such mechanical systems is challenging. Here we propose a cortical model for fine motor control of a humanoid finger, having its two last joints coupled, that learns the inverse kinematics of the effector. This neural model functionally mimics the population vector coding as well as sensorimotor prediction processes of the brain's motor/premotor and parietal regions, respectively. After learning, this neural architecture could both overtly (actual execution) and covertly (mental execution or motor imagery) perform accurate, robust and flexible finger movements while reproducing the main human finger kinematic states. This work contributes to developing neuro-mimetic controllers for dexterous humanoid robotic/prosthetic upper-extremities, and has the potential to promote human-robot interactions.

  20. Multi-fingered haptic palpation utilizing granular jamming stiffness feedback actuators

    NASA Astrophysics Data System (ADS)

    Li, Min; Ranzani, Tommaso; Sareh, Sina; Seneviratne, Lakmal D.; Dasgupta, Prokar; Wurdemann, Helge A.; Althoefer, Kaspar

    2014-09-01

    This paper describes a multi-fingered haptic palpation method using stiffness feedback actuators for simulating tissue palpation procedures in traditional and in robot-assisted minimally invasive surgery. Soft tissue stiffness is simulated by changing the stiffness property of the actuator during palpation. For the first time, granular jamming and pneumatic air actuation are combined to realize stiffness modulation. The stiffness feedback actuator is validated by stiffness measurements in indentation tests and through stiffness discrimination based on a user study. According to the indentation test results, the introduction of a pneumatic chamber to granular jamming can amplify the stiffness variation range and reduce hysteresis of the actuator. The advantage of multi-fingered palpation using the proposed actuators is proven by the comparison of the results of the stiffness discrimination performance using two-fingered (sensitivity: 82.2%, specificity: 88.9%, positive predicative value: 80.0%, accuracy: 85.4%, time: 4.84 s) and single-fingered (sensitivity: 76.4%, specificity: 85.7%, positive predicative value: 75.3%, accuracy: 81.8%, time: 7.48 s) stiffness feedback.

  1. Alpha trimmed correlation for touchless finger image mosaicing

    NASA Astrophysics Data System (ADS)

    Rao, Shishir P.; Rajendran, Rahul; Agaian, Sos S.; Mulawka, Marzena Mary Ann

    2016-05-01

    In this paper, a novel technique to mosaic multiview contactless finger images is presented. This technique makes use of different correlation methods, such as, the Alpha-trimmed correlation, Pearson's correlation [1], Kendall's correlation [2], and Spearman's correlation [2], to combine multiple views of the finger. The key contributions of the algorithm are: 1) stitches images more accurately, 2) provides better image fusion effects, 3) has better visual effect on the overall image, and 4) is more reliable. The extensive computer simulations show that the proposed method produces better or comparable stitched images than several state-of-the-art methods, such as those presented by Feng Liu [3], K Choi [4], H Choi [5], and G Parziale [6]. In addition, we also compare various correlation techniques with the correlation method mentioned in [3] and analyze the output. In the future, this method can be extended to obtain a 3D model of the finger using multiple views of the finger, and help in generating scenic panoramic images and underwater 360-degree panoramas.

  2. Orbital maneuvering end effectors

    NASA Technical Reports Server (NTRS)

    Myers, W. Neill (Inventor); Forbes, John C. (Inventor); Barnes, Wayne L. (Inventor)

    1986-01-01

    This invention relates to an end effector device for grasping and maneuvering objects such as berthing handles of a space telescope. The device includes a V-shaped capture window defined as inclined surfaces in parallel face plates which converge toward a retainer recess in which the handle is retained. A pivotal finger (30) meshes with a pair of pivoted fingers which rotate in counterrotation. The fingers rotate to pull a handle within the capture window into recess where latches lock handle in the recess. To align the capture window, plates may be cocked plus or minus five degrees on base. Drive means is included in the form of a motor coupled with a harmonic drive speed reducer, which provides for slow movement of the fingers at a high torque so that large articles may be handled. Novelty of the invention is believed to reside in the combined intermeshing finger structure, drive means and the harmonic drive speed reducer, which features provide the required maneuverability and strength.

  3. Balancing a force on the fingertip of a two-dimensional finger model without intrinsic muscles.

    PubMed

    Spoor, C W

    1983-01-01

    A slightly flexed human middle finger can balance an external force on the fingertip. Internal stabilization is also possible, which means that the externally unloaded finger can be kept stiff. We want to analyse whether in these situations the intrinsic hand muscles are needed. Distances from tendons to flexion axes are taken from the literature and are substituted in the moment equilibrium equations of a two-dimensional finger model. Diagrams illustrate the statically indeterminate problem of solving tendon forces. The possibilities for equilibrium without intrinsics appear to depend mainly on four tendon-to-joint distances. These distances determine to which of two groups a finger belongs: (1) one in which intrinsics are not necessary for internal stabilization nor for balancing a force on the fingertip in any direction in the sagittal plane; (2) one in which, without intrinsics, internal stabilization is impossible and only dorso-distally directed forces on the fingertip can be balanced.

  4. On-line confidence monitoring during decision making.

    PubMed

    Dotan, Dror; Meyniel, Florent; Dehaene, Stanislas

    2018-02-01

    Humans can readily assess their degree of confidence in their decisions. Two models of confidence computation have been proposed: post hoc computation using post-decision variables and heuristics, versus online computation using continuous assessment of evidence throughout the decision-making process. Here, we arbitrate between these theories by continuously monitoring finger movements during a manual sequential decision-making task. Analysis of finger kinematics indicated that subjects kept separate online records of evidence and confidence: finger deviation continuously reflected the ongoing accumulation of evidence, whereas finger speed continuously reflected the momentary degree of confidence. Furthermore, end-of-trial finger speed predicted the post-decisional subjective confidence rating. These data indicate that confidence is computed on-line, throughout the decision process. Speed-confidence correlations were previously interpreted as a post-decision heuristics, whereby slow decisions decrease subjective confidence, but our results suggest an adaptive mechanism that involves the opposite causality: by slowing down when unconfident, participants gain time to improve their decisions. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Radial fingering under arbitrary viscosity and density ratios

    NASA Astrophysics Data System (ADS)

    Anjos, Pedro H. A.; Dias, Eduardo O.; Miranda, José A.

    2017-08-01

    We study viscous fingering formation in radial Hele-Shaw cell geometry considering the combined action of capillary and inertial effects for arbitrary values of viscosity and density ratios. We tackle the problem by employing a perturbative mode-coupling approach and focus our attention on weakly nonlinear stages of the dynamics. If inertial effects are neglected, our theoretical results indicate that the shape of the resulting interfacial patterns is significantly affected by changes in the viscosity ratio. Under such conditions, the growing fingers tend to proliferate through a repeated ramification process (e.g., by finger bifurcation, quadrifurcation, etc.) as the capillary number is increased. Nevertheless, we find that this scenario is dramatically altered when inertia is taken into account. When inertia is relevant, the conventional finger splitting morphologies are replaced by three-lobed structures, characterized by the occurrence of sidebranching phenomena. We verify that slightly different types of sidebranched patterns arise, presenting either wide or sharp fingertips, for a range of capillary numbers and density ratios.

  6. Variations in the nerves of the thumb and index finger.

    PubMed

    Wallace, W A; Coupland, R E

    1975-11-01

    The digital nerves to the thumb and index finger have been studied by dissecting twenty-five embalmed upper limbs. The palmar digital nerves to the thumb were constant in position and course, with a short lateral cutaneous branch from the radial palmar digital nerve in 30 per cent of cases. The palmar digital nerves to the index finger had a variable pattern, the commonest arrangement, well described in Gray's Anatomy, occurring in 74 per cent of cases. The variations and their frequency are described. By examining histological cross-sections of the index finger it was found that of about 5,000 endoneurial tubes entering the finger, 60 per cent passed beyond the distal digital crease to supply the pulp and nail bed. The depth of the palmar digital nerves was about 3 millimetres, but less at the digital creases, and their diameter lay between 1 and 1.5 millimetres as far as the distal digital crease. Clinical applications of the findings are discussed.

  7. Towards the control of individual fingers of a prosthetic hand using surface EMG signals.

    PubMed

    Tenore, Francesco; Ramos, Ander; Fahmy, Amir; Acharya, Soumyadipta; Etienne-Cummings, Ralph; Thakor, Nitish V

    2007-01-01

    The fast pace of development of upper-limb prostheses requires a paradigm shift in EMG-based controls. Traditional control schemes are only capable of providing 2 degrees of freedom, which is insufficient for dexterous control of individual fingers. We present a framework where myoelectric signals from natural hand and finger movements can be decoded with a high accuracy. 32 surface-EMG electrodes were placed on the forearm of an able-bodied subject while performing individual finger movements. Using time-domain feature extraction methods as inputs to a neural network classifier, we show that 12 individuated flexion and extension movements of the fingers can be decoded with an accuracy higher than 98%. To our knowledge, this is the first instance in which such movements have been successfully decoded using surface-EMG. These preliminary findings provide a framework that will allow the results to be extended to non-invasive control of the next generation of upper-limb prostheses for amputees.

  8. Hand rehabilitation after stroke using a wearable, high DOF, spring powered exoskeleton.

    PubMed

    Tianyao Chen; Lum, Peter S

    2016-08-01

    Stroke patients often have inappropriate finger flexor activation and finger extensor weakness, which makes it difficult to open their affected hand for functional grasp. The goal was to develop a passive, lightweight, wearable device to enable improved hand function during performance of activities of daily living. The device, HandSOME II, assists with opening the patient's hand using 11 elastic actuators that apply extension torques to finger and thumb joints. Device design and initial testing are described. A novel mechanical design applies forces orthogonal to the finger segments despite the fact that all of the device DOFs are not aligned with human joint DOF. In initial testing with seven stroke subjects with impaired hand function, use of HandSOME II significantly increased maximum extension angles and range of motion in all of the index finger joints (P<;0.05). HandSOME II allows performance of all the grip patterns used in daily activities and can be used as part of home-based therapy programs.

  9. Spontaneous eye blinks are entrained by finger tapping.

    PubMed

    Cong, D-K; Sharikadze, M; Staude, G; Deubel, H; Wolf, W

    2010-02-01

    We studied the mutual cross-talk between spontaneous eye blinks and continuous, self-paced unimanual and bimanual tapping. Both types of motor activities were analyzed with regard to their time-structure in synchronization-continuation tapping tasks which involved different task instructions, namely "standard" finger tapping (Experiment 1), "strong" tapping (Experiment 2) requiring more forceful finger movements, and "impulse-like" tapping (Experiment 3) where upward-downward finger movements had to be very fast. In a further control condition (Experiment 4), tapping was omitted altogether. The results revealed a prominent entrainment of spontaneous blink behavior by the manual tapping, with bimanual tapping being more effective than unimanual tapping, and with the "strong" and "impulse-like" tapping showing the largest effects on blink timing. Conversely, we found no significant effects of the tapping on the timing of the eye blinks across all experiments. The findings suggest a functional overlap of the motor control structures responsible for voluntary, rhythmic finger movements and eye blinking behavior.

  10. Polyphasic Temporal Behavior of Finger-Tapping Performance: A Measure of Motor Skills and Fatigue.

    PubMed

    Aydin, Leyla; Kiziltan, Erhan; Gundogan, Nimet Unay

    2016-01-01

    Successive voluntary motor movement involves a number of physiological mechanisms and may reflect motor skill development and neuromuscular fatigue. In this study, the temporal behavior of finger tapping was investigated in relation to motor skills and fatigue by using a long-term computer-based test. The finger-tapping performances of 29 healthy male volunteers were analyzed using linear and nonlinear regression models established for inter-tapping interval. The results suggest that finger-tapping performance exhibits a polyphasic nature, and has several characteristic time points, which may be directly related to muscle dynamics and energy consumption. In conclusion, we believe that future studies evaluating the polyphasic nature of the maximal voluntary movement will lead to the definition of objective scales that can be used in the follow up of some neuromuscular diseases, as well as, the determination of motor skills, individual ability, and peripheral fatigue through the use of a low cost, easy-to-use computer-based finger-tapping test.

  11. Small finger protein of avian and murine retroviruses has nucleic acid annealing activity and positions the replication primer tRNA onto genomic RNA.

    PubMed Central

    Prats, A C; Sarih, L; Gabus, C; Litvak, S; Keith, G; Darlix, J L

    1988-01-01

    Retrovirus virions carry a diploid genome associated with a large number of small viral finger protein molecules which are required for encapsidation. Our present results show that finger protein p12 of Rous sarcoma virus (RSV) and p10 of murine leukaemia virus (MuLV) positions replication primer tRNA on the replication initiation site (PBS) at the 5' end of the RNA genome. An RSV mutant with a Val-Pro insertion in the finger motif of p12 is able to partially encapsidate genomic RNA but is not infectious because mutated p12 is incapable of positioning the replication primer, tRNATrp. Since all known replication competent retroviruses, and the plant virus CaMV, code for finger proteins analogous to RSV p12 or MuLV p10, the initial stage of reverse transcription in avian, mammalian and human retroviruses and in CaMV is probably controlled in an analogous way. Images PMID:2458920

  12. Small finger protein of avian and murine retroviruses has nucleic acid annealing activity and positions the replication primer tRNA onto genomic RNA.

    PubMed

    Prats, A C; Sarih, L; Gabus, C; Litvak, S; Keith, G; Darlix, J L

    1988-06-01

    Retrovirus virions carry a diploid genome associated with a large number of small viral finger protein molecules which are required for encapsidation. Our present results show that finger protein p12 of Rous sarcoma virus (RSV) and p10 of murine leukaemia virus (MuLV) positions replication primer tRNA on the replication initiation site (PBS) at the 5' end of the RNA genome. An RSV mutant with a Val-Pro insertion in the finger motif of p12 is able to partially encapsidate genomic RNA but is not infectious because mutated p12 is incapable of positioning the replication primer, tRNATrp. Since all known replication competent retroviruses, and the plant virus CaMV, code for finger proteins analogous to RSV p12 or MuLV p10, the initial stage of reverse transcription in avian, mammalian and human retroviruses and in CaMV is probably controlled in an analogous way.

  13. Coincidence avoidance principle in surface haptic interpretation

    PubMed Central

    Manuel, Steven G.; Klatzky, Roberta L.; Peshkin, Michael A.; Colgate, James Edward

    2015-01-01

    When multiple fingertips experience force sensations, how does the brain interpret the combined sensation? In particular, under what conditions are the sensations perceived as separate or, alternatively, as an integrated whole? In this work, we used a custom force-feedback device to display force signals to two fingertips (index finger and thumb) as they traveled along collinear paths. Each finger experienced a pattern of forces that, taken individually, produced illusory virtual bumps, and subjects reported whether they felt zero, one, or two bumps. We varied the spatial separation between these bump-like force-feedback regions, from being much greater than the finger span to nearly exactly the finger span. When the bump spacing was the same as the finger span, subjects tended to report only one bump. We found that the results are consistent with a quantitative model of perception in which the brain selects a structural interpretation of force signals that relies on minimizing coincidence stemming from accidental alignments between fingertips and inferred surface structures. PMID:25675477

  14. Finger drop sign-Characteristic pattern of distal weakness in Guillain-Barré Syndrome: A case report and review of the literature.

    PubMed

    Chee, Yong Chuan; Ong, Beng Hooi

    2018-01-01

    Guillain-Barré Syndrome is an acquired acute autoimmune polyradiculoneuropathy that commonly presents with limb weakness and occasional cranial nerve, respiratory and autonomic involvement. Although the classic description of Guillain-Barré Syndrome is that of a demyelinating neuropathy with ascending weakness, predominant bilateral finger drop as presenting feature has rarely been reported. A characteristic pattern of weakness involving the extensor components of the fingers known as "finger drop sign" has been first described to be specific in acute motor axonal neuropathy form of Guillain-Barré Syndrome in the literature. We report a case of acute motor-sensory axonal neuropathy, which showed characteristic pattern of predominant finger extensor weakness, and provide a summary of all reported cases to date. While previous reports suggested that this is a sign that carries good prognosis, our case report suggested otherwise as the patient succumbed to respiratory and autonomic complications. Further studies are needed to evaluate the clinical significance of this peculiar sign.

  15. Finger Forecasting: A Pointer to Athletic Prowess in Women--A Preliminary Investigation by an Undergraduate Biology Class

    ERIC Educational Resources Information Center

    Latourelle, Sandra M.; Elwess, Nancy L.; Elwess, Jennifer M.

    2008-01-01

    With all the technology today, the authors were surprised to read a recent British study that found a connection between the length of a woman's index (2D) and ring (4D) fingers to her athletic ability. Upon further investigation they found that many studies have examined the relationship between the length of the index finger (2D) to the ring…

  16. Ability of finger-jointed lumber to maintain load at elevated temperatures

    Treesearch

    Douglas R. Rammer; Samuel L. Zelinka; Laura E Hasburgh; Steven T. Craft

    2018-01-01

    This article presents a test method that was developed to screen adhesive formulations for finger-jointed lumber. The goal was to develop a small-scale test that could be used to predict whether an adhesive would pass a full-scale ASTM E119 wall assembly test. The method involved loading a 38-mm square finger-jointed sample in a four-point bending test inside of an...

  17. Prosthetic Hand Technology-Phase II

    DTIC Science & Technology

    2013-02-01

    Corporation; model number HV 1100. The motor location of the ring finger was identified and chosen for the experiments. The EMG detection system...model parameters for the experiments, where the subject performed a random series of flexion’s of the ring finger. Figure 1.6 shows the output of the...obtained from specific Motor Unit locations corresponding to the index, middle and ring finger, and the corresponding force data is presented. This is a

  18. Finger-Jointed Wood Products.

    DTIC Science & Technology

    1981-04-01

    these melamines do not have the same Urea resins are generally marketed adhesives does not always develop resistance to weathering as do in liquid form...OF durable, colorless glueline is required. been developed for use in RF curing. FINGER JOINTS MelamineUrea Resins IN STRUCTURAL Melamine - urea resins ...finger duced either by dry blending urea and moplastic, softening if temperature is joints, strength is expressed as a melamine resins or by blending

  19. A Finger-Pressing Position Detector for Assisting People with Developmental Disabilities to Control Their Environmental Stimulation through Fine Motor Activities with a Standard Keyboard

    ERIC Educational Resources Information Center

    Shih, Ching-Hsiang

    2012-01-01

    This study used a standard keyboard with a newly developed finger-pressing position detection program (FPPDP), i.e. a new software program, which turns a standard keyboard into a finger-pressing position detector, to evaluate whether two people with developmental disabilities would be able to actively perform fine motor activities to control their…

  20. Women's finger sensitivity correlates with partnered sexual behavior but not solitary masturbation frequencies.

    PubMed

    Brody, Stuart; Fischer, Agneta H; Hess, Ursula

    2008-01-01

    In a sample of 97 healthy Dutch female university students, women with greater finger tactile sensitivity (von Frey-type filaments) engaged more in partnered (but not solitary masturbation) sexual behavior. Orgasmic responses in the past 30 days were not correlated with finger sensitivity. Results are discussed in terms of differences between different sexual behaviors, as well as susceptibility to reinforcement, and psychoanalytic views of conversion hysteria.

Top