Evaluation of three percent Aqueous Film Forming Foam (AFFF) concentrates as fire fighting agents
NASA Astrophysics Data System (ADS)
Jablonski, E. J.
1981-04-01
A large-scale fire test program involving 20,000-square foot JP-4 fuel fires was conducted to evaluate the fire suppression effectiveness and compatibility of 3 percent Aqueous Film Forming Foam (AFFF) agents in Air Force fire fighting vehicles. Three commercially available 3 percent AFFF concentrates were tested in accordance with military specification MIL-F-24385B. Test results are summarized in Appendix A. As a result of these tests, an updated Revision C to this MIL SPEC has been accomplished with new requirements for both 3 percent and 6 percent AFFF extinguishing agents.
NASA Astrophysics Data System (ADS)
Subekti, P.; Hambali, E.; Suryani, A.; Suryadarma, P.
2017-05-01
This study aims to analyze the potential aplication of of palm oil-based foaming agent as peat fires fighter in Indonesia. From literature review, it has been known that the foaming agent able to form foam to extinguish fire, wrap and refrigerate the burning peat. It is necessary to develop the production and application of foaming agent in Indonesia because peat fires occur almost every year that caused smoke haze. Potential raw material for the production of environmental friendly foaming agent as foam extinguishing for peat fires in Indonesia aong other is palm oil due to abundant availability, sustainable, and foam product easily degraded in the environment of the burnt areas. Production of foaming agent as fire-fighting in Indonesia is one alternative to reduce the time to control the fire and smog disaster impact. Application of palm oil as a raw material for fire-fighting is contribute to increase the value added and the development of palm oil downstream industry.
NASA Astrophysics Data System (ADS)
Webster, Harry
2002-08-01
One or more Halon 1211 hand-held fire extinguishers are specified in Federal Aviation Regulation (FAR) Part 25.851 as a requirement on transport category aircraft with 31 or more seats. Halon 1211 has been linked to the destruction of the ozone layer and production of new Halon 1211 has been halted per the Montreal Protocol in 1993. The phase out of Halon 1211, as the hand-held firefighting agent of choice, for civilian transport category aircraft has necessitated the development of a Minimum Performance Standard (MPS) to evaluate replacement agents. The purpose of the MPS is to insure that there is no reduction in safety, both in terms of effectiveness in fighting onboard fires and toxicity to the passengers and crew. The MPS specifies two new tests that replacement agents must pass in addition to requiring national certifications such as provided by Underwriters Laboratories. The first test evaluates the "flooding" characteristics of the agent against a hidden in-flight fire. This test determines the ability of a streaming agent to function as a flooding agent. The second test evaluates the performance of the agent in fighting a terrorist fire scenario and the associated toxicity hazard. This test measures the agent's ability to extinguish a triple-seat fire in an aircraft cabin under in-flight conditions and the toxicity characteristics of both the neat agent and the products of decomposition. This MPS will insure that the replacement agents will meet or exceed the performance of Halon 1211 both in fighting fires and maintaining a safe breathing environment in aircraft cabins.
Synthesis of palm oil fatty acid as foaming agent for firefighting application
NASA Astrophysics Data System (ADS)
Rivai, M.; Hambali, E.; Suryani, A.; Fitria, R.; Firmansyah, S.; Pradesi, J.
2017-05-01
Many factors including natural factor, human carelessness, new land clearance or agricultural burning/act of vandalism and ground fire are suspected as the causes of forest fire. Foam, which cools the fire down, covers the burning material/fuel, and avoids contact between burning materials with oxygen, is an effective material used to fight large-scale fires. For this purpose, surfactant which can facilitate foam formation and inhibit the spread of smoke is required. This study was aimed at producing prototype product of foaming agent from palm oil and its formulation as a fire fighting material. Before the formulation stage, the foaming agent was resulted from saponification process of oleic, lauric, and palmitic acids by using NaOH and KOH alkaline. Foam stability was used as the main indicator of foaming agent. Results showed that potassium palmitate had the highest foam stability of 82% until the 3rd day. The best potassium palmitate concentration was 7%.
Guide Specification For Small, Dual Agent Aircraft Rescue and Firefighting Vehicles
DOT National Transportation Integrated Search
1993-12-07
This advisory circular (AC) contains performance standards, specifications, and : recommendations for the design, construction, and testing of a family of small, : dual agent aircraft rescue and fire fighting (ARFF) vehicles. The National : Fire Prot...
Aquatic Toxicity Screening of Fire Fighting Agents
2005-09-21
Aqueous Film Forming Foam ( AFFF ), the reference toxicant. The aquatic toxicity...Specification MIL-F-24385F Fire Extinguishing Agent, Aqueous Film Forming Foam ( AFFF ) Liquid Concentrate, For Fresh and Sea Water (MIL SPEC AFFF ). This...extinguish liquid hydrocarbon fuel fires involving aircraft operations. Several types of foam exist including protein, fluoroprotein and aqueous film
Treatability of Aqueous Film-Forming Foams Used for Fire Fighting.
BIODETERIORATION, *FIRE EXTINGUISHING AGENTS, SURFACE ACTIVE SUBSTANCES, FLUORINATED HYDROCARBONS, FOAM , ACTIVATED SLUDGE PROCESS, ACTIVATED CARBON, TOXICITY, WASTE DISPOSAL, TABLES(DATA), ADSORPTION.
Extinguishment and Burnback Testing of Fire Fighting Agents
2005-09-26
resisting burnback for hydrocarbon fuel fires. Potential Aqueous Film Forming Foam ( AFFF ) replacements are required to exhibit an...simple, reliable test to evaluate the effectiveness of new foams being introduced into the market as potential Aqueous Film Forming Foam ( AFFF ...normal concentrations. Reference: Military Specification MIL-F-24385F, Fire Extinguishing Agent, Aqueous Film - Forming Foam
Fire protection for a Martian colony
NASA Astrophysics Data System (ADS)
Beattie, Robert M., Jr.
The fire prevention failures that occurred in Apollo 1 and Challenger accidents are reviewed and used to discuss fire protection measures that should be taken in a Martian colony. Fire detection systems, classes of fire, and suppression agents are described. The organization of fire fighting personnel appropriate for Mars is addressed.
2004-01-01
AFFF aqueous film forming foam AFRL Air Force Research Laboratory ARFF Aircraft Rescue and...distribution system checks use a fire-fighting agent called aqueous film forming foam ( AFFF ) and generate significant amounts of AFFF wastewater. Despite its...but it has been classified as persistent, bioaccumulative, and toxic (PBT). As a result, the AFFF wastewater resulting from foam distribution
Rheology of Foam Near the Order-Disorder Phase Transition
NASA Technical Reports Server (NTRS)
Holt, R. Glynn; McDaniel, J. Gregory
1999-01-01
Foams are extremely important in a variety of industrial applications. Foams are widely used in fire-fighting applications, and are especially effective in fighting flammable liquid fires. In fact the Fire Suppression System aboard the Space Shuttle utilizes cylinders of Halon foam, which, when fired, force a rapidly expanding foam into the convoluted spaces behind instrument panels. Foams are critical in the process of enhanced oil recovery, due to their surface-active and highly viscous nature. They are also used as drilling fluids in underpressurized geologic formations. They are used as transport agents, and as trapping agents. They are also used as separation agents, where ore refinement is accomplished by froth flotation of the typically lighter and hydrophobic contaminants. The goal of the proposed investigation is the determination of the mechanical and rheological properties of foams, utilizing the microgravity environment to explore foam rheology for foams which cannot exist, or only exist for a short time, in 1g.
Aviation Engine Test Facilities (AETF) fire protection study
NASA Astrophysics Data System (ADS)
Beller, R. C.; Burns, R. E.; Leonard, J. T.
1989-07-01
An analysis is presented to the effectiveness of various types of fire fighting agents in extinguishing the kinds of fires anticipated in Aviation Engine Test Facilities (AETF), otherwise known as Hush Houses. The agents considered include Aqueous Film-Forming Foam, Halon 1301, Halon 1211 and water. Previous test work has shown the rapidity with which aircraft, especially high performance aircraft, can be damaged by fire. Based on this, tentative criteria for this evaluation included a maximum time of 20 s from fire detection to extinguishment and a period of 30 min in which the agent would prevent reignition. Other issues examined included: toxicity, corrosivity, ease of personnel egress, system reliability, and cost effectiveness. The agents were evaluated for their performance in several fire scenarios, including: under frame fire, major engine fire, engine disintegration fire, high-volume pool fire with simultaneous spill fire, internal electrical fire, and runaway engine fire.
Biocatalytic nerve agent detoxification in fire fighting foams.
LeJeune, K E; Russell, A J
1999-03-20
Current events across the globe necessitate rapid technological advances to combat the epidemic of nerve agent chemical weapons. Biocatalysis has emerged as a viable tool in the detoxification of organophosphorus neurotoxins, such as the chemical weapons VX and sarin. Efficient detoxification of contaminated equipment, machinery, and soils are of principal concern. This study describes the incorporation of a biocatalyst (organophosphorus hydrolase, E.C. 3.1.8.1) into conventional formulations of fire fighting foam. The capacity of fire fighting foams to decrease volatilization of contained contaminants, increase surface wettability, and control the rate of enzyme delivery to large areas makes them useful vehicles for enzyme application at surfaces. The performance of enzyme containing foams has been shown to be not only reproducible but also predictable. An empirical model provides reasonable estimations for the amounts of achievable surface decontamination as a function of the important parameters of the system. Theoretical modeling illustrates that the enzyme-containing foam is capable of extracting agent from the surface and is catalytically active at the foam-surface interface and throughout the foam itself. Biocatalytic foam has proven to be an effective, "environmentally friendly" means of surface and soil decontamination.
Coal Field Fire Fighting - Practiced methods, strategies and tactics
NASA Astrophysics Data System (ADS)
Wündrich, T.; Korten, A. A.; Barth, U. H.
2009-04-01
Subsurface coal fires destroy millions of tons of coal each year, have an immense impact to the ecological surrounding and threaten further coal reservoirs. Due to enormous dimensions a coal seam fire can develop, high operational expenses are needed. As part of the Sino-German coal fire research initiative "Innovative technologies for exploration, extinction and monitoring of coal fires in Northern China" the research team of University of Wuppertal (BUW) focuses on fire extinction strategies and tactics as well as aspects of environmental and health safety. Besides the choice and the correct application of different extinction techniques further factors are essential for the successful extinction. Appropriate tactics, well trained and protected personnel and the choice of the best fitting extinguishing agents are necessary for the successful extinction of a coal seam fire. The chosen strategy for an extinction campaign is generally determined by urgency and importance. It may depend on national objectives and concepts of coal conservation, on environmental protection (e.g. commitment to green house gases (GHG) reductions), national funding and resources for fire fighting (e.g. personnel, infrastructure, vehicles, water pipelines); and computer-aided models and simulations of coal fire development from self ignition to extinction. In order to devise an optimal fire fighting strategy, "aims of protection" have to be defined in a first step. These may be: - directly affected coal seams; - neighboring seams and coalfields; - GHG emissions into the atmosphere; - Returns on investments (costs of fire fighting compared to value of saved coal). In a further step, it is imperative to decide whether the budget shall define the results, or the results define the budget; i.e. whether there are fixed objectives for the mission that will dictate the overall budget, or whether the limited resources available shall set the scope within which the best possible results shall be achieved. For an effective and efficient fire fighting optimal tactics are requiered and can be divided into four fundamental tactics to control fire hazards: - Defense (digging away the coal, so that the coal can not begin to burn; or forming a barrier, so that the fire can not reach the not burning coal), - Rescue the coal (coal mining of a not burning seam), - Attack (active and direct cooling of burning seam), - Retreat (only monitoring till self-extinction of a burning seam). The last one is used when a fire exceeds the organizational and/or technical scope of a mission. In other words, "to control a coal fire" does not automatically and in all situations mean "to extinguish a coal fire". Best-practice tactics or a combination of them can be selected for control of a particular coal fire. For the extinguishing works different extinguishing agents are available. They can be applied by different application techniques and varying distinctive operating expenses. One application method may be the drilling of boreholes from the surface or covering the surface with low permeability soils. The mainly used extinction agents for coal field fire are as followed: Water (with or without additives), Slurry, Foaming mud/slurry, Inert gases, Dry chemicals and materials and Cryogenic agents. Because of its tremendous dimension and its complexity the worldwide challenge of coal fires is absolutely unique - it can only be solved with functional application methods, best fitting strategies and tactics, organisation and research as well as the dedication of the involved fire fighters, who work under extreme individual risks on the burning coal fields.
Aquatic Toxicity Screening of Fire Fighting Agents; 2003 Report
2003-06-02
Aqueous Film Forming Foam ( AFFF ), the reference toxicant. The aquatic toxicity screening consisted of an acute, static, range-finding...five concentrations of 3M Light Water Brand Aqueous Film Forming Foam ( AFFF ), the reference toxicant. The aquatic toxicity screening consisted of an...experimental foam concentrates against current Military Specification MIL-F-24385F Fire Extinguishing Agent, Aqueous Film Forming Foam
Fire Extinguishing Agents, Aqueous Film Forming Foam (AFFF) Liquid Concentration Partial Percentage
1989-08-31
AFFF concentrations. aqueous film forming foam , AFFF , firefighting ...Extinguishing Agents, Aqueous Film Forming Foam ( AFFF ) Liquid Concentration Partial Percentage F08637-88-C-0067 06022104F 2104 30 21043034 Applied Research...objective of this test series was to qualify 3/4 and 1 percent Aqueous Film Forming Foam ( AFFF ) concentrate for use in Air Force fire fighting
Aircraft Hangar Fire Suppression System Evaluation-Intermediate- Scale Studies
1999-12-23
aqueous film forming foam ( AFFF ) extinguishing systems [1]. The overhead AFFF system typically consists of standard closed head sprinklers that...of Water Spray on Fire-Fighting Foam ," Fire Journal, 63 (6), November 1969. 5. MIL-F-24385F, "Fire Extinguishing Agent, Aqueous Film Forming Foam ...extinguishing capability of the foam and the ability of the blanket to resist burnback. When AFFF is applied over a flammable liquid spill
29 CFR Appendix B to Subpart L of... - National Consensus Standards
Code of Federal Regulations, 2014 CFR
2014-07-01
.... NFPA No. 13E, Fire Department Operations in Properties Protected by Sprinkler, Standpipe Systems. ANSI..., Water Supplies for Suburban and Rural Fire Fighting. 1910.159 ANSI-NFPA No. 13, Sprinkler Systems. NFPA No. 13A, Sprinkler Systems, Maintenance. ANSI/NFPA No. 18, Wetting Agents. ANSI/NFPA No. 20...
29 CFR Appendix B to Subpart L of... - National Consensus Standards
Code of Federal Regulations, 2012 CFR
2012-07-01
.... NFPA No. 13E, Fire Department Operations in Properties Protected by Sprinkler, Standpipe Systems. ANSI..., Water Supplies for Suburban and Rural Fire Fighting. 1910.159 ANSI-NFPA No. 13, Sprinkler Systems. NFPA No. 13A, Sprinkler Systems, Maintenance. ANSI/NFPA No. 18, Wetting Agents. ANSI/NFPA No. 20...
29 CFR Appendix B to Subpart L of... - National Consensus Standards
Code of Federal Regulations, 2011 CFR
2011-07-01
.... NFPA No. 13E, Fire Department Operations in Properties Protected by Sprinkler, Standpipe Systems. ANSI..., Water Supplies for Suburban and Rural Fire Fighting. 1910.159 ANSI-NFPA No. 13, Sprinkler Systems. NFPA No. 13A, Sprinkler Systems, Maintenance. ANSI/NFPA No. 18, Wetting Agents. ANSI/NFPA No. 20...
29 CFR Appendix B to Subpart L of... - National Consensus Standards
Code of Federal Regulations, 2013 CFR
2013-07-01
.... NFPA No. 13E, Fire Department Operations in Properties Protected by Sprinkler, Standpipe Systems. ANSI..., Water Supplies for Suburban and Rural Fire Fighting. 1910.159 ANSI-NFPA No. 13, Sprinkler Systems. NFPA No. 13A, Sprinkler Systems, Maintenance. ANSI/NFPA No. 18, Wetting Agents. ANSI/NFPA No. 20...
46 CFR 153.907 - Cargo information.
Code of Federal Regulations, 2011 CFR
2011-10-01
... exposed to the cargo. (7) A list of fire fighting procedures and extinguishing agents effective with cargo fires. (8) Shipper's name. (9) Loading point. (10) Approximate quantity of cargo. (11) Tank in which the... of these two tables. (2) The name of the cargo prescribed in the letter authorizing carriage of the...
46 CFR 153.907 - Cargo information.
Code of Federal Regulations, 2014 CFR
2014-10-01
... exposed to the cargo. (7) A list of fire fighting procedures and extinguishing agents effective with cargo fires. (8) Shipper's name. (9) Loading point. (10) Approximate quantity of cargo. (11) Tank in which the... of these two tables. (2) The name of the cargo prescribed in the letter authorizing carriage of the...
46 CFR 153.907 - Cargo information.
Code of Federal Regulations, 2013 CFR
2013-10-01
... exposed to the cargo. (7) A list of fire fighting procedures and extinguishing agents effective with cargo fires. (8) Shipper's name. (9) Loading point. (10) Approximate quantity of cargo. (11) Tank in which the... of these two tables. (2) The name of the cargo prescribed in the letter authorizing carriage of the...
Evaluation of Three Percent Aqueous Film Forming Foam (AFFF) Concentrates as Fire Fighting Agents.
1981-04-01
Three percent AFFF formulations are currently available to meet the requirements of proposed Revision C to Military Specifi- cation MIL - F - 24385 . The fire...also result in savings for shipping and storage costs. Therefore, Appendix B contains proposed Revision C to MIL - F - 24385 . It includes requirements for
ERIC Educational Resources Information Center
Sleigh, John; Plevey, Ray
1986-01-01
Provides background information for teachers on the chemistry of flourine. Points out that it links aerosols with refrigerants, anaesthetics with fire-fighting agents, batteries with blood substitutes, and atomic energy with the steel, petroleum, and aluminum industries. (JN)
75 FR 221 - Airworthiness Directives; Fire Fighting Enterprises Limited Portable Halon 1211 Fire...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-05
... Airworthiness Directives; Fire Fighting Enterprises Limited Portable Halon 1211 Fire Extinguishers as Installed... specification, have been supplied to the aviation industry for use in fire extinguishing equipment. * * * * * * * * * * * This Halon 1211 has subsequently been used to fill certain FFE [Fire Fighting Enterprises] portable...
NASA Astrophysics Data System (ADS)
Sripramai, Keerati; Oikawa, Yasushi; Watanabe, Hiroshi; Katada, Toshitaka
Generally, in order to improve some regional fire fighting validity, indispensable strategies are not only a reinforcement of the governmental fire fighting ability, but also a strengthening of the cooperative relationship between governmental and non-governmental fire fighting ability. However, for practical purposes, the effective strategy should be different depending on the actual situationin the subject area. So, in this study, we grasp the actual state and background of the problems that need to be solved for the improvement of the regional fire fighting validity in Bangkok as a case study, and examine the appropriate solution focusing on the relationship between official and voluntary fire fighting. Through some practicable activities such as interviews, investigati ons, and making the regional fire fighting validity map, it became clear that the problems of uncooperative relationship and the lack of trust between stakeholders should be solved first and foremost.
46 CFR 167.45-30 - Use of approved fire-fighting equipment.
Code of Federal Regulations, 2010 CFR
2010-10-01
... PUBLIC NAUTICAL SCHOOL SHIPS Special Firefighting and Fire Prevention Requirements § 167.45-30 Use of approved fire-fighting equipment. Portable fire extinguishers or fire-extinguishing systems which conform... 46 Shipping 7 2010-10-01 2010-10-01 false Use of approved fire-fighting equipment. 167.45-30...
14 CFR 121.106 - ETOPS Alternate Airport: Rescue and fire fighting service.
Code of Federal Regulations, 2011 CFR
2011-01-01
... augmented to meet paragraph (a) of this section from local fire fighting assets. A 30-minute response time... fighting service. 121.106 Section 121.106 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT... and Flag Operations § 121.106 ETOPS Alternate Airport: Rescue and fire fighting service. (a) Except as...
14 CFR 121.106 - ETOPS Alternate Airport: Rescue and fire fighting service.
Code of Federal Regulations, 2010 CFR
2010-01-01
... augmented to meet paragraph (a) of this section from local fire fighting assets. A 30-minute response time... fighting service. 121.106 Section 121.106 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT... and Flag Operations § 121.106 ETOPS Alternate Airport: Rescue and fire fighting service. (a) Except as...
46 CFR 185.524 - Fire fighting drills and training.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Fire fighting drills and training. 185.524 Section 185... 100 GROSS TONS) OPERATIONS Preparations for Emergencies § 185.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar...
46 CFR 185.524 - Fire fighting drills and training.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false Fire fighting drills and training. 185.524 Section 185... 100 GROSS TONS) OPERATIONS Preparations for Emergencies § 185.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar...
46 CFR 185.524 - Fire fighting drills and training.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 7 2014-10-01 2014-10-01 false Fire fighting drills and training. 185.524 Section 185... 100 GROSS TONS) OPERATIONS Preparations for Emergencies § 185.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar...
46 CFR 185.524 - Fire fighting drills and training.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 7 2012-10-01 2012-10-01 false Fire fighting drills and training. 185.524 Section 185... 100 GROSS TONS) OPERATIONS Preparations for Emergencies § 185.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar...
46 CFR 185.524 - Fire fighting drills and training.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false Fire fighting drills and training. 185.524 Section 185... 100 GROSS TONS) OPERATIONS Preparations for Emergencies § 185.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar...
46 CFR 122.524 - Fire fighting drills and training.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Fire fighting drills and training. 122.524 Section 122... Preparations for Emergencies § 122.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a...
46 CFR 122.524 - Fire fighting drills and training.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Fire fighting drills and training. 122.524 Section 122... Preparations for Emergencies § 122.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a...
46 CFR 122.524 - Fire fighting drills and training.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Fire fighting drills and training. 122.524 Section 122... Preparations for Emergencies § 122.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a...
46 CFR 122.524 - Fire fighting drills and training.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Fire fighting drills and training. 122.524 Section 122... Preparations for Emergencies § 122.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a...
46 CFR 122.524 - Fire fighting drills and training.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Fire fighting drills and training. 122.524 Section 122... Preparations for Emergencies § 122.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a...
1995-01-01
FURTHER ACTION DECISION UNDER CERCLAI STUDY AREA 31 MOORE ARMY AIRFIELD FIRE FIGHTING TRAINING AREA FORT DEVENS , MASSACHUSETFS TABLE OF CONTENTS jSection...Inc. 31DD.DOC 6917.11 111,, NO FURTHER ACTION DECISION UNDER CERCLA I STUDY AREA 31 MOORE ARMY AIRFIELD FIRE FIGHTING TRAINING AREA 3 FORT DEVENS ...Fire Fighting Training Area) at Fort Devens , Massachusetts, have resulted in the decision that no further studies or remediation are required at this
US Coast Guard lightweight fire-fighting module
NASA Astrophysics Data System (ADS)
1980-05-01
The U.S. Coast Guard Fire-fighting Module developed for the purpose of fighting fires in harbors and on ships is described. The module can be lifted by a dockside crane or helicopter and placed on the deck of a patrol boat or cutter for transportation to the scene of the fire. At the fire the module can be set up and put in operation by a crew of two in approximately fifteen minutes. Once in operation the module will deliver water to two fire nozzles at a pressure of 150 psi and a flow rate of 2000 gpm. Sufficient fuel is carried in the module for three hours of continuous operation. A record of the development of the fire fighting module is also presented.
US Coast Guard lightweight fire-fighting module
NASA Technical Reports Server (NTRS)
1980-01-01
The U.S. Coast Guard Fire-fighting Module developed for the purpose of fighting fires in harbors and on ships is described. The module can be lifted by a dockside crane or helicopter and placed on the deck of a patrol boat or cutter for transportation to the scene of the fire. At the fire the module can be set up and put in operation by a crew of two in approximately fifteen minutes. Once in operation the module will deliver water to two fire nozzles at a pressure of 150 psi and a flow rate of 2000 gpm. Sufficient fuel is carried in the module for three hours of continuous operation. A record of the development of the fire fighting module is also presented.
46 CFR 109.223 - Fire fighting equipment.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Fire fighting equipment. 109.223 Section 109.223 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Tests, Drills, and Inspections § 109.223 Fire fighting equipment. The master or person in charge...
46 CFR 109.223 - Fire fighting equipment.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Fire fighting equipment. 109.223 Section 109.223 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Tests, Drills, and Inspections § 109.223 Fire fighting equipment. The master or person in charge...
46 CFR 109.223 - Fire fighting equipment.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Fire fighting equipment. 109.223 Section 109.223 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Tests, Drills, and Inspections § 109.223 Fire fighting equipment. The master or person in charge...
46 CFR 109.223 - Fire fighting equipment.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Fire fighting equipment. 109.223 Section 109.223 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Tests, Drills, and Inspections § 109.223 Fire fighting equipment. The master or person in charge...
46 CFR 109.223 - Fire fighting equipment.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Fire fighting equipment. 109.223 Section 109.223 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Tests, Drills, and Inspections § 109.223 Fire fighting equipment. The master or person in charge...
14 CFR 91.815 - Agricultural and fire fighting airplanes: Noise operating limitations.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 2 2011-01-01 2011-01-01 false Agricultural and fire fighting airplanes... RULES Operating Noise Limits § 91.815 Agricultural and fire fighting airplanes: Noise operating limitations. (a) This section applies to propeller-driven, small airplanes having standard airworthiness...
14 CFR 91.815 - Agricultural and fire fighting airplanes: Noise operating limitations.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 2 2013-01-01 2013-01-01 false Agricultural and fire fighting airplanes... RULES Operating Noise Limits § 91.815 Agricultural and fire fighting airplanes: Noise operating limitations. (a) This section applies to propeller-driven, small airplanes having standard airworthiness...
14 CFR 91.815 - Agricultural and fire fighting airplanes: Noise operating limitations.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 2 2012-01-01 2012-01-01 false Agricultural and fire fighting airplanes... RULES Operating Noise Limits § 91.815 Agricultural and fire fighting airplanes: Noise operating limitations. (a) This section applies to propeller-driven, small airplanes having standard airworthiness...
14 CFR 91.815 - Agricultural and fire fighting airplanes: Noise operating limitations.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Agricultural and fire fighting airplanes... RULES Operating Noise Limits § 91.815 Agricultural and fire fighting airplanes: Noise operating limitations. (a) This section applies to propeller-driven, small airplanes having standard airworthiness...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-23
... Equipment, Training and Drills Onboard Offshore Facilities and Mobile Offshore Drilling Units (MODUs... lifesaving and fire-fighting equipment, training and drills on board offshore facilities and MODUs operating... guidance concerning lifesaving and fire-fighting equipment, training, and drills onboard manned offshore...
Donald N. Matthews
1940-01-01
Fire fighting is still largely a hand-work job in the heavy cover and fuel conditions and rugged topography of the Douglas fir region, in spite of recent advances that have been made in %he use of machinery. Controlling a fire in this region requires immense amounts of work per unit of fire perimeter, so that large numbers of men are required to attack all but the...
STS-42 crewmembers participate in JSC fire fighting training exercises
NASA Technical Reports Server (NTRS)
1991-01-01
STS-42 Discovery, Orbiter Vehicle (OV) 103, Payload Specialist Ulf D. Merbold (far left), fire fighting trainer (center), Payload Specialist Roberta L. Bondar (holding hose nozzle), and backup Payload Specialist Roger K. Crouch position water hoses in the direction of a blazing fire in JSC's Fire Training Pit. The crewmembers and backup are learning fire extinguishing techniques during fire fighting and fire training exercises held at JSC's Fire Training Pit located across from the Gilruth Center Bldg 207. Merbold is representing the European Space Agency (ESA) and Bondar is representing Canada during the International Microgravity Laboratory 1 (IML-1) mission aboard OV-103.
1989-01-01
This Uruguayan Decree sets forth regulations on the prevention and fighting of forest fires. Among other things, it does the following: 1) requires all public and private organizations, as well as all persons, to assist personally in and provide vehicles, machines, and tools for the fighting of forest fires; 2) requires the owners of property containing forests to maintain instruction in fighting fires for an adequate number of employees; 3) requires all forests to be kept cleared of vegetation capable of spreading fires and to have fire walls; 4) requires owners of forests larger than 30 hectares in size to present to the Forest Directorate an annual plan for forest fire defense; and 5) requires owners of forests larger than 30 hectares in size to maintain specified equipment for fighting fires. Persons violating the provisions of this Decree are subject to fines.
Crisis management with applicability on fire fighting plants
NASA Astrophysics Data System (ADS)
Panaitescu, M.; Panaitescu, F. V.; Voicu, I.; Dumitrescu, L. G.
2017-08-01
The paper presents a case study for a crisis management analysis which address to fire fighting plants. The procedures include the steps of FTA (Failure tree analysis). The purpose of the present paper is to describe this crisis management plan with tools of FTA. The crisis management procedures have applicability on anticipated and emergency situations and help to describe and planning a worst-case scenario plan. For this issue must calculate the probabilities in different situations for fire fighting plants. In the conclusions of paper is analised the block diagram with components of fire fighting plant and are presented the solutions for each possible risk situations.
Measuring wildland fire fighter performance with wearable technology.
Parker, Richard; Vitalis, Antonios; Walker, Robyn; Riley, David; Pearce, H Grant
2017-03-01
Wildland (rural) fire fighting is a physically demanding and hazardous occupation. An observational study was conducted to explore the use of new technologies for the field study of fire fighters at wildfires and to understand the work pressures of wildland fire fighting. The research was carried out with two fire fighters at real fires wearing microphones, miniature video cameras, heart rate monitors and GPS units to record their actions and location at wildfire events. The fire fighters were exposed to high physiological workloads (heart rates of up to 180 beats per minute) and walked considerable distances at the fires. Results from this study have been used in presentations to fire fighters and non-operational fire personnel to understand the pressures fire fighters are under and how others complete the fire fighting tasks. Copyright © 2016 Elsevier Ltd. All rights reserved.
Use of Seawater for Fighting Electrical Fires
1989-05-25
56,300 microsiemens/cm, after mixing with the AFFF concentrate (3M Company’s FC 206 CE brand). In view of this similarity in conductivity, it is not...gpm Nozzle ... ...... 7 Feecon Dual Agent Nozzle, 95 gpm ... ...... 7 Portable AFFF Extinguisher .... ......... 7 EXPERIMENTAL PROCEDURES...29 Fresh Watet "Oest ..... .............. . 29 AFFF Test ...... .................. . 29 Proposed Type III Nozzle Test Results .... 29
A WebGIS-based command control system for forest fire fighting
NASA Astrophysics Data System (ADS)
Yang, Jianyu; Ming, Dongping; Zhang, Xiaodong; Huang, Haitao
2006-10-01
Forest is a finite resource and fire prevention is crucial work. However, once a forest fire or accident occurs, timely and effective fire-fighting is the only necessary measure. The aim of this research is to build a computerized command control system based on WEBGIS to direct fire-fighting. Firstly, this paper introduces the total technique flow and functional modules of the system. Secondly, this paper analyses the key techniques for building the system, and they are data obtaining, data organizing & management, architecture of WebGIS and sharing & interoperation technique. In the end, this paper demonstrates the on line martial symbol editing function to show the running result of system. The practical application of this system showed that it played very important role in the forest fire fighting work. In addition, this paper proposes some strategic recommendations for the further development of the system.
STS-30 crewmembers participate in fire fighting training at JSC
NASA Technical Reports Server (NTRS)
1989-01-01
STS-30 Atlantis, Orbiter Vehicle (OV) 104, crewmembers participate in fire fighting training at JSC's fire training pit across from the Gilruth Center Bldg 207. Commander David M. Walker and Pilot Ronald J. Grabe use fire extinguishers to control blaze. Fire / security staff member Robert Fife coaches the two crewmembers during the training exercise.
STS-47 crew participates in fire fighting exercises at JSC Fire Training Pit
NASA Technical Reports Server (NTRS)
1992-01-01
STS-47 Endeavour, Orbiter Vehicle (OV) 105, Mission Specialist (MS) N. Jan Davis (foreground) and MS and Payload Commander (PLC) Mark C. Lee, squinting and holding water hose, listen to instructions prior to participating in fire fighting exercises held at JSC's Fire Training Pit across from Gilruth Center Bldg 207.
Fighting fire with fire: attacking the complexity of human tumors with armed therapeutic viruses.
Hermiston, Terry
2002-08-01
Cancer gene therapies have centered on the use of a single gene, directed against a particular property or single aspect of tumor biology, to treat neoplastic disease. These therapies have met with limited clinical success. This is, perhaps, not surprising given the complex and heterogeneous nature of solid tumors. Treatments targeted at confronting multiple dimensions of human tumors are needed. Armed therapeutic viruses (oncolytic viruses carrying therapeutic genes) represent a system where the concerted action of multiple therapeutics can be joined into a single agent, and represent a promising avenue for developing future cancer therapies.
STS-48 crew participates in JSC fire fighting and fire training exercises
NASA Technical Reports Server (NTRS)
1991-01-01
In this overall view, STS-48 crewmembers approach a firey blaze armed with water hoses. Left to right are Mission Specialist (MS) Charles D. Gemar, Pilot Kenneth S. Reightler, Jr, an unidentified fire department Official, MS Mark N. Brown, and Commander John O. Creighton. These fire fighting and fire training exercises were conducted at JSC's Fire Training Pit located across from the Gilruth Center Bldg 207.
STS-48 crew participates in JSC fire fighting and fire training exercises
NASA Technical Reports Server (NTRS)
1991-01-01
STS-48 Mission Specialist (MS) Charles D. Gemar opens water hose nozzle as he approaches a fire blazing in JSC's Fire Training Pit during fire fighting and fire training exercises. Pilot Kenneth S. Reightler, Jr steadies the hose behind Gemar. At Gemars right is an unidentified fire department Official, MS Mark N. Brown, and Commander John O. Creighton. Brown and Crieghton are obscured by the water spray. The Fire Training Pit is located across from the Gilruth Center Bldg 207.
NASA helicopter helps fight fire at KSC
NASA Technical Reports Server (NTRS)
2000-01-01
A NASA helicopter takes off to bring water to fight a small fire on Kennedy Space Center grounds. The site is between Kennedy Parkway North and the Indian River. The fire is one of many throughout Central Florida, which is suffering from drought.
An assessment of air quality impacts of fires associated with fire fighting operations.
Leahey, D M; Hansen, M C; Schroeder, M B
1993-03-01
Fire fighters in Canada's navy must undergo regular training with fires from simulated helicopter crashes. Visible emissions from these fires often create health concerns in surrounding communities. This paper presents air quality implications of plume dispersion associated with "helicopter fires." Evaluations involved measuring plume rise, estimating emissions, dispersion modeling and ambient monitoring. Results of the evaluation provided ground-level concentration estimates of plume particulate matter, oxides of nitrogen, hydrogen fluoride, carbon monoxide, 22 metals, 15 PAH and 13 VOC. The study showed that the air quality impact of the fire fighting training is much lower than the relevant time-weighted averages established to protect workers' health. This paper will be of interest to people in environmental protection agencies because it demonstrates the effects of fire fighting operations that must frequently occur as part of training exercises.
Fire fighting aboard ships. Volume 1: Hazard analysis and behavior of combustible materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stavitskiy, M.G.; Kortunov, M.F.; Sidoryuk, V.M.
1983-01-01
The volume zeros in on fire hazards on ships afloat or under construction/repair. It examines fire hazards peculiar to ships carrying particular cargoes, such as dry-cargo ships, tankers, and factory and fishing vessels. This volume examines specific features of fire-fighting equipment, along with the thermal behavior of materials used in shipbuilding.
ERIC Educational Resources Information Center
Cordell, Curtis C.; And Others
A training effectiveness evaluation of the Navy Advanced Fire Fighting Training System was conducted. This system incorporates simulated fires as well as curriculum materials and instruction. The fires are non-pollutant, computer controlled, and installed in a simulated shipboard environment. Two teams of 15 to 16 persons, with varying amounts of…
NASA helicopter helps fight brush fire at KSC
NASA Technical Reports Server (NTRS)
2000-01-01
A NASA helicopter flies over fire-fighting equipment and personnel in order to drop its load of water on a wildfire at KSC. Before being extinguished, the fire burned about 20 acres at a site near gate 2C on Kennedy Parkway North (route 3).
NASA helicopter helps fight brush fire at KSC
NASA Technical Reports Server (NTRS)
2000-01-01
A NASA helicopter dips its fire-fighting bucket into the river to pick up and deliver a cargo of water to a wildfire at KSC. Before being extinguished, the fire burned about 20 acres at a site near gate 2C on Kennedy Parkway North (route 3).
Cascading effects of fire exclusion in the Rocky Mountain ecosystems: a literature review
Robert E. Keane; Kevin C. Ryan; Tom T. Veblen; Craig D. Allen; Jessie Logan; Brad Hawkes
2002-01-01
The health of many Rocky Mountain ecosystems is in decline because of the policy of excluding fire in the management of these ecosystems. Fire exclusion has actually made it more difficult to fight fires, and this poses greater risks to the people who fight fires and for those who live in and around Rocky Mountain forests and rangelands. This paper discusses the extent...
Light, Compact Pumper for Harbor Fires
NASA Technical Reports Server (NTRS)
Burns, R. A.
1983-01-01
Report describes development of new transportable water-pumping unit for fire-fighting. Compact, self-contained unit provides fire protection at coastal and inland ports and is lighter than standard firetruck pumper of same capacity. Used to fight fires in harbors, cities, forests, refineries, chemical plants, and offshore drilling platforms. Other possible applications include cleaning up oilspills, pumping out ships, and flood control pumping.
Information processing in an urban fire department communication system.
Siegel, J; Weitzman, D O
1975-09-01
One of the most important functions of any fire department is to provide selective contact with fire fighting units and to dispatch these units based on information gathered from street alarm boxes and telephones. This paper is concerned with the problem of dispatching tactical response information to remote fire fighting units and with the effect of workload on the dispatch function.
STS-48 crew participates in JSC fire fighting and fire training exercises
NASA Technical Reports Server (NTRS)
1991-01-01
STS-48 Pilot Kenneth S. Reightler, Jr directs water hose nozzle as Mission Specialist (MS) Charles D. Gemar pulls the hose toward the blaze. In the background, an unidentified fire department Official instructs Commander John O. Creighton and MS Mark N. Brown (wearing cap), manning a second hose, on how to approach the blaze. These fire fighting and fire training exercises were conducted at JSC's Fire Training Pit located across from the Gilruth Center Bldg 207.
Fernández-Fernández, M; Gómez-Rey, M X; González-Prieto, S J
2015-05-15
The study addresses a knowledge-gap in the long-term ecological consequences of fire and fire-fighting chemicals. Ten years after a prescribed fire and the application of three fire-fighting chemicals, their effects on the soil-plant system were evaluated. Five treatments were established: unburnt soils (US) and burnt soils treated with water alone (BS), foaming agent (BS+Fo), Firesorb (BS+Fi) and ammonium polyphosphate (BS+Ap). Soils (0-2 cm depth) and foliar material of shrubs (Erica umbellata, Pterospartum tridentatum and Ulex micranthus) and trees (Pinus pinaster) were analysed for total N, δ(15)N, and soil-available and plant total macronutrients and trace elements. Soil pH, NH₄(+)-N and NO₃(-)-N; pine basal diameter and height; and shrub cover and height were also measured. Compared with US plots, burnt soils had less nitrates and more Mo. Although differences were not always significant, BS+Ap had the highest levels of soil available P, Na and Al. Plants from BS+Ap plots had higher values of δ(15)N (P. pinaster and E. umbellata), P (all species), Na (P. tridentatum and U. micranthus) and Mg (E. umbellata and P. tridentatum) than other treatments; while K in plants from BS+Ap plots was the highest among treatments for P. pinaster and the lowest for the shrubs. Pines in US plots were higher and wider than in burnt treatments, except for BS+Ap, where the tallest and widest trees were found, although half of them were either dead (the second highest mortality after BS+Fi) or had a distorted trunk. BS+Ap was the treatment with strongest effects on plants, showing E. umbellata the lowest coverage and height, P. tridentatum the highest coverage, U. micranthus one of the lowest coverages and being the only treatment where Genista triacanthos was absent. Consequently, it is concluded that both fire and ammonium polyphosphate application had significant effects on the soil-plant system after 10 years. Copyright © 2015 Elsevier B.V. All rights reserved.
Job Language Performance Requirements for MOS 11C Indirect Fire Infantryman.
1982-10-01
1009 *Apply artificial respiration to a chemical- agent casualty. 092-503-1004 Recognize and protect self against a chemical biological (CB) hazard...position (81-rm, 107-mm (4.2 in). 071-326-5704 Supervise/evaluate construction of a fighting position. .1 tS e~ SECURITY AND INTELLIGNECE ’PERCENTAGE...tackbone airway adam’s apple breastbone almost airtight finger-width any alongside oxygenated apply aloud arcs artificial as long as bulges assist
2010-03-01
release; distribution unlimited. Ref AFRL/RXQ Public Affairs Case # 10-100. Document contains color images . Although aqueous fire fighting agent...in conjunction with the standard Eulerian multiphase flow model. The two- equation k- model was selected due to its wide industrial application in...energy (k) and its dissipation rate (). Because of their heuristic development, RANS models have applicable limitations and in general must be
Chemical Action of Halogenated Agents in Fire Extinguishing
NASA Technical Reports Server (NTRS)
Belles, Frank E.
1955-01-01
The action of halogenated agents in preventing flame propagation in fuel-air mixtures in laboratory tests is discussed in terms of a possible chemical mechanism. The mechanism chosen is that of chain-breaking reactions between agent and active particles (hydrogen and oxygen atoms and hydroxyl radicsls). Data from the literature on the flammability peaks of n-heptane agent-air mixtures are treated. Ratings of agent effectiveness in terms of the fuel equivalent of the agent, based on both fuel and agent concentrations at the peak, are proposed as preferable to ratings in terms of agent concentration alone. These fuel-equivalent ratings are roughly correlated by reactivities assigned to halogen and hydrogen atoms in the agent molecules. It is concluded that the presence of hydrogen in agent need not reduce its fire-fighting ability, provided there is enough halogen to make the agent nonflammable. A method is presented for estimating from quenching-distance data a rate constant for the reaction of agent with active particles. A quantitative result is obtained for methyl bromide. This rate constant predicts the observed peak concentration of methyl bromide quite well. However, more data are needed to prove the validity of the method. The assumption that hal.ogenatedagents act mainly by chain-bresking reactions with active particles is consistent with the experimental facts and should help guide the selection of agents for further tests.
STS-30 crewmembers participate in fire fighting training at JSC
NASA Technical Reports Server (NTRS)
1989-01-01
STS-30 Atlantis, Orbiter Vehicle (OV) 104, crewmembers participate in fire fighting training at JSC's fire training pit across from the Gilruth Center Bldg 207. Crewmembers listen to hose and nozzle instructions given by fire / security staff member Robert Fife. Left to right Commander David M. Walker (holding hose nozzle), Mission Specialist (MS) Mark C. Lee, MS Mary L. Cleave, Pilot Ronald J. Grabe, and MS Norman E. Thagard.
Fire Fighting from High Altitude
NASA Technical Reports Server (NTRS)
Cobleigh, Brent; Ambrosia, Vince
2007-01-01
A viewgraph presentation on high altitude fire fighting is shown. The topics include: 1) Yellowstone Fire - 1988; 2) 2006 Western States Fire Mission Over-View; 3) AMS-Wildfire Scanner; 4) October 24-25 Mission: Yosemite NP and NF; 5) October 24-25 Mission MODIS Overpass; 6) October 24-25 Mission Highlights; 7) October 28-29 Mission Esperanza Fire, California; 8) Response to the Esperanza Fire in Southern California -- Timeline Oct 27-29 2006; 9) October 28-29 Mission Esperanza Fire Altair Flight Routing; 10) October 28-29 Mission Esperanza Fire Altair Over-Flights; 11) October 28-29 Mission Highlights; 12) Results from the Esperanza Fire Response; 13) 2007 Western States Fire Mission; and 14) Western States UAS Fire Mission 2007
14 CFR 121.106 - ETOPS Alternate Airport: Rescue and fire fighting service.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false ETOPS Alternate Airport: Rescue and fire... and Flag Operations § 121.106 ETOPS Alternate Airport: Rescue and fire fighting service. (a) Except as... available at each airport listed as an ETOPS Alternate Airport in a dispatch or flight release. (1) For...
14 CFR 121.106 - ETOPS Alternate Airport: Rescue and fire fighting service.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false ETOPS Alternate Airport: Rescue and fire... and Flag Operations § 121.106 ETOPS Alternate Airport: Rescue and fire fighting service. (a) Except as... available at each airport listed as an ETOPS Alternate Airport in a dispatch or flight release. (1) For...
14 CFR 121.106 - ETOPS Alternate Airport: Rescue and fire fighting service.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false ETOPS Alternate Airport: Rescue and fire... and Flag Operations § 121.106 ETOPS Alternate Airport: Rescue and fire fighting service. (a) Except as... available at each airport listed as an ETOPS Alternate Airport in a dispatch or flight release. (1) For...
Biodegradability of fluorinated fire-fighting foams in water.
Bourgeois, A; Bergendahl, J; Rangwala, A
2015-07-01
Fluorinated fire-fighting foams may be released into the environment during fire-fighting activities, raising concerns due to the potential environmental and health impacts for some fluorinated organics. The current study investigated (1) the biodegradability of three fluorinated fire-fighting foams, and (2) the applicability of current standard measures used to assess biodegradability of fluorinated fire-fighting foams. The biodegradability of three fluorinated fire-fighting foams was evaluated using a 28-day dissolved organic carbon (DOC) Die-Away Test. It was found that all three materials, diluted in water, achieved 77-96% biodegradability, meeting the criteria for "ready biodegradability". Defluorination of the fluorinated organics in the foam during biodegradation was measured using ion chromatography. It was found that the fluorine liberated was 1-2 orders of magnitude less than the estimated initial amount, indicating incomplete degradation of fluorinated organics, and incomplete CF bond breakage. Published biodegradability data may utilize biochemical oxygen demand (BOD), chemical oxygen demand (COD), and total organic carbon (TOC) metrics to quantify organics. COD and TOC of four fluorinated compounds were measured and compared to the calculated carbon content or theoretical oxygen demand. It was found that the standard dichromate-based COD test did not provide an accurate measure of fluorinated organic content. Thus published biodegradability data using COD for fluorinated organics quantification must be critically evaluated for validity. The TOC measurements correlated to an average of 91% of carbon content for the four fluorinated test substances, and TOC is recommended for use as an analytical parameter in fluorinated organics biodegradability tests. Copyright © 2015 Elsevier Ltd. All rights reserved.
STS-29 crewmembers participate in fire fighting training at JSC
NASA Technical Reports Server (NTRS)
1988-01-01
STS-29 Discovery, Orbiter Vehicle (OV) 103, crewmembers participate in fire fighting training at JSC's fire training pit across from the Gilruth Center Bldg 207. Mission Specialist (MS) Robert C. Springer (left) and Pilot John E. Blaha, controlling water hose nozzles, approach the blaze and attempt to extinguish it. They are followed by fire / security staff member Robert Fife (between hoses), Commander Michael L. Coats (left), and MS James P. Bagian.
NASA Astrophysics Data System (ADS)
Wuttke, M. W.; Halisch, M.; Tanner, D. C.; Cai, Z. Y.; Zeng, Q.; Wang, C.
2012-04-01
Spontaneous uncontrolled coal seam fires are a well known phenomenon that causes severe environmental problems and severe impact on natural coal reserves. Coal fires are a worldwide phenomenon, but in particular in Xinjiang, that covers 17.3 % of Chinas area and hosts approx 42 % of its coal resources. In Xinjiang since more than 50 years a rigorous strategy for fire fighting on local and regional scale is persued. The Xinjiang Coalfield Fire Fighting Bureau (FFB) has developed technologies and methods to deal with any known fire. Many fires have been extinguished already, but the problem is still there if not even growing. This problem is not only a problem for China due to the loss of valuable energy resources, but it is also a worldwide threat because of the generation of substantial amounts of greenhouse gases. Through the FFB, China is struggling to overcome this, but the activities could be much enhanced by the continuation of the already successful conjoint operations. The last ten years have seen two successful cooperative projects between China and Germany on the field of coal-fire fighting, namely the German Technical Cooperation Project on Coal Fire in Xinjiang and the Sino-German Coal Fire Research Initiative funded by the corresponding ministeries of both countries. A persistent task in the fire fighting is the identification and supervision of areas with higher risks for the ignition of coal fires, the exploration of already ignited fire zones to extinguish the fires and the monitoring of extinguished fires to detect as early as possible process that may foster re-ignition. This can be achieved by modeling both the structures and the processes that are involved. This has also been a promising part of the past cooperation projects, yet to be transformed into a standard application of fire fighting procedures. In this contribution we describe the plans for a new conjoint project between China and Germany where on the basis of field investigations and laboratory measurements realistic dynamical models of fire-zones are constructed to increase the understanding of particular coal-fires, to interpret the surface signatures of the coal-fire in terms of location and propagation and to estimate the output of hazardous exhaust products to evaluate the economic benefit of fire extinction.
Physiological responses to fire fighting activities.
Romet, T T; Frim, J
1987-01-01
Eight professional fire fighters participated in six fire fighting scenarios at a training facility. Data on heart rate (HR), rectal temperature (Tre), and skin temperatures at the chest and thigh were collected using a portable data acquisition system. Average HR ranged from 122 to 151 beats.min-1 during the six scenarios. Detailed analyses indicated that HR and Tre increases are related to both the physical and environmental stresses of the various activities carried out. The most demanding activity, that of building search and victim rescue, resulted in an average HR of 153 beats.min-1 and Tre rise of 1.3 degree C, while the least demanding activity, that of the crew captain who directs the fire fighting, resulted in an average HR of only 122 beats.min-1 and a Tre rise of only 0.3 degree C. This study shows that fire fighting is strenuous work for those directly entering a building and performing related duties, but that the physical demands of other activities are considerably less. The results further suggest that heat strain injuries in fire fighters could perhaps be reduced by rotating duties frequently with other crew members performing less stressful work.
NASA Astrophysics Data System (ADS)
Snarski, Steve; Menozzi, Alberico; Sherrill, Todd; Volpe, Chris; Wille, Mark
2010-04-01
This paper describes experimental results from recent live-fire data collects that demonstrate the capability of a prototype system for projectile detection and tracking. This system, which is being developed at Applied Research Associates, Inc., under the FightSight program, consists of a high-speed thermal camera and sophisticated image processing algorithms to detect and track projectiles. The FightSight operational vision is automated situational intelligence to detect, track, and graphically map large-scale firefights and individual shooting events onto command and control (C2) systems in real time (shot location and direction, weapon ID, movements and trends). Gaining information on enemy-fire trajectories allows educated inferences on the enemy's intent, disposition, and strength. Our prototype projectile detection and tracking system has been tested at the Joint Readiness Training Center (Ft Polk, LA) during live-fire convoy and mortar registration exercises, in the summer of 2009. It was also tested during staged military-operations- on-urban-terrain (MOUT) firefight events at Aberdeen Test Center (Aberdeen, MD) under the Hostile Fire Defeat Army Technology Objective midterm experiment, also in the summer of 2009, where we introduced fusion with acoustic and EO sensors to provide 3D localization and near-real time display of firing events. Results are presented in this paper that demonstrate effective and accurate detection and localization of weapon fire (5.56mm, 7.62mm, .50cal, 81/120mm mortars, 40mm) in diverse and challenging environments (dust, heat, day and night, rain, arid open terrain, urban clutter). FightSight's operational capabilities demonstrated under these live-fire data collects can support closecombat scenarios. As development continues, FightSight will be able to feed C2 systems with a symbolic map of enemy actions.
STS-32 crewmembers use water hoses during fire fighting training at JSC
1989-09-22
STS-32 crewmembers use water hoses during fire fighting exercises at JSC's Fire Training Pit across from the Gilruth Center Bldg 207. Mission Specialist (MS) G. David Low with nozzle open directs water into the fire as fire/ security personnel coaches and instructs him on his attempt to extinguish the blaze. MS Bonnie J. Dunbar maneuvers the hose behind Low. A second group of crewmembers alongside Low and Dunbar, MS Marsha S. Ivins, holding hose nozzle, Commander Daniel C. Brandenstein, and Pilot James D. Wetherbee position themselves before opening hose nozzle.
STS-32 crewmembers use water hoses during fire fighting training at JSC
NASA Technical Reports Server (NTRS)
1989-01-01
STS-32 crewmembers use water hoses during fire fighting exercises at JSC's Fire Training Pit across from the Gilruth Center Bldg 207. Mission Specialist (MS) G. David Low with nozzle open directs water into the fire as fire/ security personnel coaches and instructs him on his attempt to extinguish the blaze. MS Bonnie J. Dunbar maneuvers the hose behind Low. A second group of crewmembers alongside Low and Dunbar, MS Marsha S. Ivins, holding hose nozzle, Commander Daniel C. Brandenstein, and Pilot James D. Wetherbee position themselves before opening hose nozzle.
Plowes, Nicola J.R; Adams, Eldridge S
2005-01-01
Lanchester's models of attrition describe casualty rates during battles between groups as functions of the numbers of individuals and their fighting abilities. Originally developed to describe human warfare, Lanchester's square law has been hypothesized to apply broadly to social animals as well, with important consequences for their aggressive behaviour and social structure. According to the square law, the fighting ability of a group is proportional to the square of the number of individuals, but rises only linearly with fighting ability of individuals within the group. By analyzing mortality rates of fire ants (Solenopsis invicta) fighting in different numerical ratios, we provide the first quantitative test of Lanchester's model for a non-human animal. Casualty rates of fire ants were not consistent with the square law; instead, group fighting ability was an approximately linear function of group size. This implies that the relative numbers of casualties incurred by two fighting groups are not strongly affected by relative group sizes and that battles do not disproportionately favour group size over individual prowess. PMID:16096093
NASA Astrophysics Data System (ADS)
Filizzola, Carolina; Belloni, Antonella; Benigno, Giuseppe; Biancardi, Alberto; Corrado, Rosita; Coviello, Irina; De Costanzo, Giovanni; Genzano, Nicola; Lacava, Teodosio; Lisi, Mariano; Marchese, Francesco; Mazzeo, Giuseppe; Merzagora, Cinzio; Paciello, Rossana; Pergola, Nicola; Sannazzaro, Filomena; Serio, Salvatore; Tramutoli, Valerio
2013-04-01
Every year, hundreds of thousands of hectares of European forests are destroyed by fires. Due to the particular topography, landscape and demographic distribution in Europe (very different from typical scenarios of China, USA, Canada and Australia), rapidity in fire sighting is still the determining factor in limiting damages to people and goods. Moreover, the possibility of early fire detection means also potentially to reduce the size of the event to be faced, the necessary fire fighting resources and, therefore, even the reaction times. In such a context, integration of satellite technologies (mainly high temporal resolution data) and traditional surveillance systems within the fire fighting procedures seems to positively impact on the effectiveness of active fire fighting as demonstrated by recent experiences over Italian territory jointly performed by University of Basilicata, IMAA-CNR and Local Authorities. Real time implementation was performed since 2007, during fire seasons, over several Italian regions with different fire regimes and features, in order to assess the actual potential of different satellite-based fire detection products to support regional and local authorities in efficiently fighting fires and better mitigating their negative effects. Real-time campaigns were carried out in strict collaboration with end-users within the framework of specific projects (i.e. the AVVISA, AVVISTA and AVVISA-Basilicata projects) funded by Civil Protection offices of Regione Lombardia, Provincia Regionale di Palermo and Regione Basilicata in charge of fire risk management and mitigation. A tailored training program was dedicated to the personnel of Regional Civil Protection offices in order to ensure the full understanding and the better integration of satellite based products and tools within the existing fire fighting protocols. In this work, outcomes of these practices are shown and discussed, especially highlighting the impact that a real time satellite system may have in assisting and complementing traditional surveillance systems to mitigate damages due to fires. In particular, the usefulness of satellite technology in an operational context was demonstrated mainly in reference to: i) the possibility of identifying fires at an early stage (so avoiding that small hotbeds could extend and become dangerous for citizens and destructive for environmental protected areas) as well as ii) the possibility to have an effective territorial control (e.g. discovering illegal burning fires such as unauthorized cleaning fires, and permitting local authorities to rapidly intervene and catch red-handed pyromaniacs).
14 CFR 91.815 - Agricultural and fire fighting airplanes: Noise operating limitations.
Code of Federal Regulations, 2014 CFR
2014-01-01
...: Noise operating limitations. 91.815 Section 91.815 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... RULES Operating Noise Limits § 91.815 Agricultural and fire fighting airplanes: Noise operating limitations. (a) This section applies to propeller-driven, small airplanes having standard airworthiness...
NASA Astrophysics Data System (ADS)
Rychkov, A. D.
2009-06-01
The work of a pulsed aerosol system for fire fighting is modelled, which is designed for fire fighting at oil storages and at the spills of oil products, whose vapors were modelled by gaseous methane. The system represents a device for separate installation, which consists of a charge of solid propellant (the gas generator) and a container with fine-dispersed powder of the flame-damper substance. The methane combustion was described by a one-stage gross-reaction, the influence of the concentration of vapors of the flame-damper substance on the combustion process was taken into account by reducing the pre-exponent factor in the Arrhenius law and was described by an empirical dependence. The computational experiment showed that the application of the pulsed aerosol system for fire fighting ensures an efficient transport of fine-dispersed aerosol particles of the flame-damping substance and its forming vapors to the combustion zone; the concentration of particles ensures the damping of the heat source.
Evaluation of a wearable physiological status monitor during simulated fire fighting activities.
Smith, Denise L; Haller, Jeannie M; Dolezal, Brett A; Cooper, Christopher B; Fehling, Patricia C
2014-01-01
A physiological status monitor (PSM) has been embedded in a fire-resistant shirt. The purpose of this research study was to examine the ability of the PSM-shirt to accurately detect heart rate (HR) and respiratory rate (RR) when worn under structural fire fighting personal protective equipment (PPE) during the performance of various activities relevant to fire fighting. Eleven healthy, college-aged men completed three activities (walking, searching/crawling, and ascending/descending stairs) that are routinely performed during fire fighting operations while wearing the PSM-shirt under structural fire fighting PPE. Heart rate and RR recorded by the PSM-shirt were compared to criterion values measured concurrently with an ECG and portable metabolic measurement system, respectively. For all activities combined (overall) and for each activity, small differences were found between the PSM-shirt and ECG (mean difference [95% CI]: overall: -0.4 beats/min [-0.8, -0.1]; treadmill: -0.4 beats/min [-0.7, -0.1]; search: -1.7 beats/min [-3.1, -.04]; stairs: 0.4 beats/min [0.04, 0.7]). Standard error of the estimate was 3.5 beats/min for all tasks combined and 1.9, 5.9, and 1.9 beats/min for the treadmill walk, search, and stair ascent/descent, respectively. Correlations between the PSM-shirt and criterion heart rates were high (r = 0.95 to r = 0.99). The mean difference between RR recorded by the PSM-shirt and criterion overall was 1.1 breaths/min (95% CI: -1.9 to -0.4). The standard error of the estimate for RR ranged from 4.2 breaths/min (treadmill) to 8.2 breaths/min (search), with an overall value of 6.2 breaths/min. These findings suggest that the PSM-shirt provides valid measures of HR and useful approximations of RR when worn during fire fighting duties.
Emergency Management Computer-Aided Trainer (EMCAT)
NASA Technical Reports Server (NTRS)
Rodriguez, R. C.; Johnson, R. P.
1986-01-01
The Emergency Management Computer-Aided Trainer (EMCAT) developed by Essex Corporation or NASA and the Federal Emergency Management Administration's (FEMA) National Fire Academy (NFA) is described. It is a computer based training system for fire fighting personnel. A prototype EMCAT system was developed by NASA first using video tape images and then video disk images when the technology became available. The EMCAT system is meant to fill the training needs of the fire fighting community with affordable state-of-the-art technologies. An automated real time simulation of the fire situation was needed to replace the outdated manual training methods currently being used. In order to be successful, this simulator had to provide realism, be user friendly, be affordable, and support multiple scenarios. The EMCAT system meets these requirements and therefore represents an innovative training tool, not only for the fire fighting community, but also for the needs of other disciplines.
Capability Portfolio Analysis Tool (CPAT) Verification and Validation Report
2013-01-01
BFSB Battlefield Surveillance Brigade BFV Bradley Fighting Vehicle BMOD Bradley Modernization C2 (H) Command and Control (HBCT) C2 (S...Fire Infantry Fighting Vehicle (IFV); Fire Integrated Support Team (FIST); Engineer (Eng); Cavalry (CAV) BFV FOV CDD Block II - 16 Apr 2010 GCV FOV
14 CFR 36.1583 - Noncomplying agricultural and fire fighting airplanes.
Code of Federal Regulations, 2013 CFR
2013-01-01
... airplanes. 36.1583 Section 36.1583 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Limitations and Information § 36.1583 Noncomplying agricultural and fire fighting airplanes. (a) This section applies to propeller-driven, small airplanes that— (1) Are designed for “agricultural aircraft operations...
14 CFR 36.1583 - Noncomplying agricultural and fire fighting airplanes.
Code of Federal Regulations, 2011 CFR
2011-01-01
... airplanes. 36.1583 Section 36.1583 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Limitations and Information § 36.1583 Noncomplying agricultural and fire fighting airplanes. (a) This section applies to propeller-driven, small airplanes that— (1) Are designed for “agricultural aircraft operations...
14 CFR 36.1583 - Noncomplying agricultural and fire fighting airplanes.
Code of Federal Regulations, 2012 CFR
2012-01-01
... airplanes. 36.1583 Section 36.1583 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Limitations and Information § 36.1583 Noncomplying agricultural and fire fighting airplanes. (a) This section applies to propeller-driven, small airplanes that— (1) Are designed for “agricultural aircraft operations...
14 CFR 36.1583 - Noncomplying agricultural and fire fighting airplanes.
Code of Federal Regulations, 2014 CFR
2014-01-01
... airplanes. 36.1583 Section 36.1583 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Limitations and Information § 36.1583 Noncomplying agricultural and fire fighting airplanes. (a) This section applies to propeller-driven, small airplanes that— (1) Are designed for “agricultural aircraft operations...
14 CFR 36.1583 - Noncomplying agricultural and fire fighting airplanes.
Code of Federal Regulations, 2010 CFR
2010-01-01
... airplanes. 36.1583 Section 36.1583 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Limitations and Information § 36.1583 Noncomplying agricultural and fire fighting airplanes. (a) This section applies to propeller-driven, small airplanes that— (1) Are designed for “agricultural aircraft operations...
Aircraft Carrier Flight Deck Fire Fighting Tactics and Equipment Evaluation Tests
1987-02-26
pattern nozzles; 8. proper fire fighting techniques for possible titanium ignition in an F-14 crash (deleted later by direction of FLSC, being studied ...separately); 9. effect of full fire involvement of "ready for flight" aircraft (deleted later by direction of FLSC, being studied separately). The...to refine and identify specific hardware and tactical requirements generated from the studies conducted during the scoping tests; 3. concept
STS-42 crewmembers participate in JSC fire fighting training exercises
NASA Technical Reports Server (NTRS)
1991-01-01
STS-42 Discovery, Orbiter Vehicle (OV) 103, Mission Specialist (MS) Norman E. Thagard, holding hose nozzle, is followed by Payload Specialist Ulf D. Merbold and backup Payload Specialist Kenneth Money as the team positions the water hose in the direction of a blazing fire at JSC's Fire Training Pit. A second team of crewmembers, manning another hose, forms a line parallel to the first. The crewmembers and backups are learning fire extinguishing techniques during fire fighting and fire training exercises held at JSC's Fire Training Pit located across from the Gilruth Center Bldg 207. Merbold is representing the European Space Agency (ESA) during the International Microgravity Laboratory 1 (IML-1) mission aboard OV-103.
29 CFR 1910.159 - Automatic sprinkler systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
... supply is out of service, except for systems of 20 or fewer sprinklers. (5) Hose connections for fire fighting use. The employer may attach hose connections for fire fighting use to wet pipe sprinkler systems... 29 Labor 5 2010-07-01 2010-07-01 false Automatic sprinkler systems. 1910.159 Section 1910.159...
29 CFR 1910.159 - Automatic sprinkler systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
... supply is out of service, except for systems of 20 or fewer sprinklers. (5) Hose connections for fire fighting use. The employer may attach hose connections for fire fighting use to wet pipe sprinkler systems... 29 Labor 5 2013-07-01 2013-07-01 false Automatic sprinkler systems. 1910.159 Section 1910.159...
29 CFR 1910.159 - Automatic sprinkler systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
... supply is out of service, except for systems of 20 or fewer sprinklers. (5) Hose connections for fire fighting use. The employer may attach hose connections for fire fighting use to wet pipe sprinkler systems... 29 Labor 5 2014-07-01 2014-07-01 false Automatic sprinkler systems. 1910.159 Section 1910.159...
29 CFR 1910.159 - Automatic sprinkler systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
... supply is out of service, except for systems of 20 or fewer sprinklers. (5) Hose connections for fire fighting use. The employer may attach hose connections for fire fighting use to wet pipe sprinkler systems... 29 Labor 5 2012-07-01 2012-07-01 false Automatic sprinkler systems. 1910.159 Section 1910.159...
29 CFR 1910.159 - Automatic sprinkler systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
... supply is out of service, except for systems of 20 or fewer sprinklers. (5) Hose connections for fire fighting use. The employer may attach hose connections for fire fighting use to wet pipe sprinkler systems... 29 Labor 5 2011-07-01 2011-07-01 false Automatic sprinkler systems. 1910.159 Section 1910.159...
Indicator Systems for School and Teacher Evaluation: Fire-Fighting It Is!
ERIC Educational Resources Information Center
Fitz-Gibbon, C. T.
In 1979, Gene Glass suggested that it might not be possible to evaluate schools nor to create widely applicable research findings, but that the complexity of education was such that merely "fire-fighting," establishing monitoring systems to alert about educational events, was the best approach. In the United Kingdom, monitoring systems…
Three-dimensional tracking for efficient fire fighting in complex situations
NASA Astrophysics Data System (ADS)
Akhloufi, Moulay; Rossi, Lucile
2009-05-01
Each year, hundred millions hectares of forests burn causing human and economic losses. For efficient fire fighting, the personnel in the ground need tools permitting the prediction of fire front propagation. In this work, we present a new technique for automatically tracking fire spread in three-dimensional space. The proposed approach uses a stereo system to extract a 3D shape from fire images. A new segmentation technique is proposed and permits the extraction of fire regions in complex unstructured scenes. It works in the visible spectrum and combines information extracted from YUV and RGB color spaces. Unlike other techniques, our algorithm does not require previous knowledge about the scene. The resulting fire regions are classified into different homogenous zones using clustering techniques. Contours are then extracted and a feature detection algorithm is used to detect interest points like local maxima and corners. Extracted points from stereo images are then used to compute the 3D shape of the fire front. The resulting data permits to build the fire volume. The final model is used to compute important spatial and temporal fire characteristics like: spread dynamics, local orientation, heading direction, etc. Tests conducted on the ground show the efficiency of the proposed scheme. This scheme is being integrated with a fire spread mathematical model in order to predict and anticipate the fire behaviour during fire fighting. Also of interest to fire-fighters, is the proposed automatic segmentation technique that can be used in early detection of fire in complex scenes.
Lidar Technique for Early Forest Fire Detection : Design and Development Aspects
NASA Astrophysics Data System (ADS)
Traïche, M.; Bourai, K.; Moussaoui, N.; Beggar, R.; Almabouada, F.; Louhibi, D.
2008-09-01
Many countries suffer from forest fires every summer, a phenomenon which wreaks havoc on both local and global environment. As well, it causes enormous damage to public health especially for people living in surrounding areas. For fighting against forest fires, ocular surveillance, in spite of its wide use, is not efficient owing to the costly mobilization of a great number of forest agents and to the fact that most of forest regions are not accessible. Other passive techniques such as infrared camera remote sensing are neither efficient under unfavorable weather conditions. An efficient way to early detect forest fires even under worse environmental conditions and in inaccessible mountainous regions uses the backscattering Lidar technique. This consists of the emission of monowavelength laser pulses spanning azimuthally the entire region subject to surveillance and the detection of the backscattered signal. The detection parameter is the signal to noise ration SNR. In this contribution, we will deal with approach and design aspects inherent to the development task of such a Lidar.
Fight Fire Without Fire Fighters!
ERIC Educational Resources Information Center
Peacock, Richard D.
1977-01-01
There is a role for the classroom teacher in teaching fire safety. Discusses the inadequacies of present fire prevention programs and provides ten specific steps teachers can take to avoid suffering and death from fire. (Author/RK)
Gaikowski, Mark P.; Hamilton, Steven J.; Buhl, Kevin J.; McDonald, Susan F.; Summers, Cliff H.; Linder, G.; Krest, S.; Sparling, D.; Little, E.
1996-01-01
Laboratory studies were conducted with five early life stages of rainbow trout, Oncorhynchus mykiss, to determine the acute toxicities of five fire-fighting chemical formulations in standardized soft and hard water. Eyed egg, embryo–larvae, swim-up fry, and 60- and 90-d posthatch juveniles were exposed to three fire retardants (Fire-Trol LCG-R, Fire-Trol GTS-R, and Phos-Chek D75-F) and two fire-suppressant foams (Phos-Chek WD-881 and Silv-Ex). Swim-up fry were generally the most sensitive life stage, whereas the eyed-egg was the least sensitive. Toxicity of fire-fighting formulations was greater in hard water than in soft water for all life stages tested with Fire-Trol GTS-R and Silv-Ex and for 90-d-old juveniles tested with Fire-Trol LCG-R. The fire-suppressant foams were more toxic than the fire retardants. The 96-h median lethal concentrations (LC50s) were ranked from the most toxic to the least toxic formulation as follows (ranges are the lowest and highest 96-h LC50 calculated for each formulation): Phos-Chek WD-881 (11–44 mg/L), Silv-Ex (11–78 mg/L), Phos-Chek D75-F (218–>3,600 mg/L), Fire-Trol GTS-R (207–>6,000 mg/L), and Fire-Trol LCG-R (872–>10,000 mg/L). Toxicity values suggest that accidental entry of fire-fighting chemicals into aquatic environments could adversely affect fish populations.
Consequences of Fire: The Killing Fumes
... Electric Vehicles Fire Fighter Safety and Response for Solar Power Systems Fire Fighting Tactics Under Wind Driven ... Protection Devices Development of Fire Mitigations Solutions for PV Systems Installed on Building Roofs - Phase 1 Electric/ ...
Oygard, Joar Karsten; Måge, Amund; Gjengedal, Elin; Svane, Tore
2005-01-01
Landfill leachates sampled during and after an accidental landfill fire were analysed and the levels of selected metals and chemical compounds compared to those occurring in the leachate under normal conditions. The fire at the landfill site was put out by excavation and cooling by use of water. The investigation during the fire and fire fight revealed a moderate increase in the level of nitrogen and also in pH and conductivity. Heavy metals and COD in the leachate showed considerably increased levels. In general, the determined variables appeared to normalise within one week after the fire was extinguished. It can be concluded that landfill fires extinguished by excavation may lead to elevated leachate levels of especially COD and heavy metals, but that this is only a short-term effect.
NASA Astrophysics Data System (ADS)
Yin, Hang; Jin, Hui; Zhao, Ying; Fan, Yuguang; Qin, Liwu; Chen, Qinghong; Huang, Liya; Jia, Xiang; Liu, Lijie; Dai, Yuhong; Xiao, Ying
2018-03-01
The forest-fire not only brings great loss to natural resources, but also destructs the ecosystem and reduces the soil fertility, causing some natural disasters as soil erosion and debris flow. However, due to the lack of the prognosis for forest fire spreading trend in forest fire fighting, it is difficult to formulate rational and effective fire-fighting scheme. In the event of forest fire, achieving accurate judgment to the fire behavior would greatly improve the fire-fighting efficiency, and reduce heavy losses caused by fire. Researches on forest fire spread simulation can effectively reduce the loss of disasters. The present study focused on the simulation of "29 May 2012" wildfire in windthrow area of Changbai Mountain. Basic data were retrieved from the "29 May 2012" wildfire and field survey. A self-development forest fire behavior simulated program based on Rothermel Model was used in the simulation. Kappa coefficient and Sørensen index were employed to evaluate the simulation accuracy. The results showed that: The perimeter of simulated burned area was 4.66 km, the area was 56.47 hm2 and the overlapped burned area was 33.68 hm2, and the estimated rate of fire spread was 0.259 m/s. Between the simulated fire and actual fire, the Kappa coefficient was 0.7398 and the Sørensen co-efficient was 0.7419. This proved the application of Rothermel model to conduct fire behavior simulation in windthrow meadow was feasible. It can achieve the goal of forecasting for the spread behavior in windthrow area of Changbai Mountain. Thus, our self-development program based on the Rothermel model can provide a effective forecast of fire spread, which will facilitate the fire suppression work.
Estimating suppression expenditures for individual large wildland fires
Krista M. Gebert; David E. Calkin; Jonathan Yoder
2007-01-01
The extreme cost of fighting wildland fires has brought fire suppression expenditures to the forefront of budgetary and policy debate in the United States. Inasmuch as large fires are responsible for the bulk of fire suppression expenditures, understanding fire characteristics that influence expenditures is important for both strategic fire planning and onsite fire...
Fire and the Design of Educational Buildings. Building Bulletin 7. Sixth Edition.
ERIC Educational Resources Information Center
Department of Education and Science, London (England).
This bulletin offers guidance on English school premises regulations applying to safety protection against fires in the following general areas: means of escape in case of fire; precautionary measures to prevent fire; fire warning systems and fire fighting; fire spreading speed; structures and materials resistant to fires; and damage control. It…
STS-47 crew during JSC fire fighting exercises in the Fire Training Pit
NASA Technical Reports Server (NTRS)
1992-01-01
STS-47 Endeavour, Orbiter Vehicle (OV) 105, crewmembers line up along water hoses during JSC fire fighting exercises held at JSC's Fire Training Pit. In the foreground are (left to right) Pilot Curtis L. Brown, Jr, holding the hose nozzle, Mission Specialist (MS) N. Jan Davis, MS and Payload Commander (PLC) Mark C. Lee, and backup Payload Specialist Stan Koszelak, partially visible at the end of the line. In the background, manning a second hose are backup Payload Specialist Takao Doi, MS Jerome Apt, and Commander Robert L. Gibson. A veteran fire fighter (behind Brown) stands between the two hoses giving instructions. The Fire Training Pit is located across from the Gilruth Center Bldg 207. Doi represents Japan's National Space Development Agency (NASDA).
Applying Open Source Game Engine for Building Visual Simulation Training System of Fire Fighting
NASA Astrophysics Data System (ADS)
Yuan, Diping; Jin, Xuesheng; Zhang, Jin; Han, Dong
There's a growing need for fire departments to adopt a safe and fair method of training to ensure that the firefighting commander is in a position to manage a fire incident. Visual simulation training systems, with their ability to replicate and interact with virtual fire scenarios through the use of computer graphics or VR, become an effective and efficient method for fire ground education. This paper describes the system architecture and functions of a visual simulated training system of fire fighting on oil storage, which adopting Delat3D, a open source game and simulation engine, to provide realistic 3D views. It presents that using open source technology provides not only the commercial-level 3D effects but also a great reduction of cost.
Monitoring system of multiple fire fighting based on computer vision
NASA Astrophysics Data System (ADS)
Li, Jinlong; Wang, Li; Gao, Xiaorong; Wang, Zeyong; Zhao, Quanke
2010-10-01
With the high demand of fire control in spacious buildings, computer vision is playing a more and more important role. This paper presents a new monitoring system of multiple fire fighting based on computer vision and color detection. This system can adjust to the fire position and then extinguish the fire by itself. In this paper, the system structure, working principle, fire orientation, hydrant's angle adjusting and system calibration are described in detail; also the design of relevant hardware and software is introduced. At the same time, the principle and process of color detection and image processing are given as well. The system runs well in the test, and it has high reliability, low cost, and easy nodeexpanding, which has a bright prospect of application and popularization.
Training Fires on Indian Reservations in Idaho, Oregon, and Washington
The Federal Air Rules for Reservations (FARR) Open Burning Rule allows Fire Protection Services to request permission from EPA to conduct an outdoor burn by qualified personnel to train firefighters on fire suppression and fire fighting techniques.
NASA Astrophysics Data System (ADS)
Almer, Alexander; Schnabel, Thomas; Perko, Roland; Raggam, Johann; Köfler, Armin; Feischl, Richard
2016-04-01
Climate change will lead to a dramatic increase in damage from forest fires in Europe by the end of this century. In the Mediterranean region, the average annual area affected by forest fires has quadrupled since the 1960s (WWF, 2012). The number of forest fires is also on the increase in Central and Northern Europe. The Austrian forest fire database shows a total of 584 fires for the period 2012 to 2014, while even large areas of Sweden were hit by forest fires in August 2014, which were brought under control only after two weeks of intense fire-fighting efforts supported by European civil protection modules. Based on these facts, the improvements in forest fire control are a major international issue in the quest to protect human lives and resources as well as to reduce the negative environmental impact of these fires to a minimum. Within this paper the development of a multi-functional airborne management support system within the frame of the Austrian national safety and security research programme (KIRAS) is described. The main goal of the developments is to assist crisis management tasks of civil emergency teams and armed forces in disaster management by providing multi spectral, near real-time airborne image data products. As time, flexibility and reliability as well as objective information are crucial aspects in emergency management, the used components are tailored to meet these requirements. An airborne multi-functional management support system was developed as part of the national funded project AIRWATCH, which enables real-time monitoring of natural disasters based on optical and thermal images. Airborne image acquisition, a broadband line of sight downlink and near real-time processing solutions allow the generation of an up-to-date geo-referenced situation map. Furthermore, this paper presents ongoing developments for innovative extensions and research activities designed to optimize command operations in national and international fire-fighting missions. The ongoing development focuses on the following topics: (1) Development of a multi-level management solution to coordinate and guide different airborne and terrestrial deployed firefighting modules as well as related data processing and data distribution activities. (2) Further, a targeted control of the thermal sensor based on a rotating mirror system to extend the "area performance" (covered area per hour) in time critical situations for the monitoring requirements during forest fire events. (3) Novel computer vision methods for analysis of thermal sensor signatures, which allow an automatic classification of different forest fire types and situations. (4) A module for simulation-based decision support for planning and evaluation of resource usage and the effectiveness of performed fire-fighting measures. (5) Integration of wearable systems to assist ground teams in rescue operations as well as a mobile information system into innovative command and fire-fighting vehicles. In addition, the paper gives an outlook on future perspectives including a first concept for the integration of the near real-time multilevel forest fire fighting management system into an "EU Civil Protection Team" to support the EU civil protection modules and the Emergency Response Coordination Centre in Brussels. Keywords: Airborne sensing, multi sensor imaging, near real-time fire monitoring, simulation-based decision support, forest firefighting management, firefighting impact analysis.
Limitations imposed on fire PRA methods as the result of incomplete and uncertain fire event data.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nowlen, Steven Patrick; Hyslop, J. S.
2010-04-01
Fire probabilistic risk assessment (PRA) methods utilize data and insights gained from actual fire events in a variety of ways. For example, fire occurrence frequencies, manual fire fighting effectiveness and timing, and the distribution of fire events by fire source and plant location are all based directly on the historical experience base. Other factors are either derived indirectly or supported qualitatively based on insights from the event data. These factors include the general nature and intensity of plant fires, insights into operator performance, and insights into fire growth and damage behaviors. This paper will discuss the potential methodology improvements thatmore » could be realized if more complete fire event reporting information were available. Areas that could benefit from more complete event reporting that will be discussed in the paper include fire event frequency analysis, analysis of fire detection and suppression system performance including incipient detection systems, analysis of manual fire fighting performance, treatment of fire growth from incipient stages to fully-involved fires, operator response to fire events, the impact of smoke on plant operations and equipment, and the impact of fire-induced cable failures on plant electrical circuits.« less
29 CFR 1926.155 - Definitions applicable to this subpart.
Code of Federal Regulations, 2014 CFR
2014-07-01
... part, fire resistance shall be determined by the Standard Methods of Fire Tests of Building... knowledgeable, trained, and skilled in the safe evacuation of employees during emergency situations and in assisting in fire fighting operations. (f) Fire resistance means so resistant to fire that, for specified...
29 CFR 1926.155 - Definitions applicable to this subpart.
Code of Federal Regulations, 2012 CFR
2012-07-01
... part, fire resistance shall be determined by the Standard Methods of Fire Tests of Building... knowledgeable, trained, and skilled in the safe evacuation of employees during emergency situations and in assisting in fire fighting operations. (f) Fire resistance means so resistant to fire that, for specified...
29 CFR 1926.155 - Definitions applicable to this subpart.
Code of Federal Regulations, 2011 CFR
2011-07-01
... part, fire resistance shall be determined by the Standard Methods of Fire Tests of Building... knowledgeable, trained, and skilled in the safe evacuation of employees during emergency situations and in assisting in fire fighting operations. (f) Fire resistance means so resistant to fire that, for specified...
29 CFR 1926.155 - Definitions applicable to this subpart.
Code of Federal Regulations, 2013 CFR
2013-07-01
... part, fire resistance shall be determined by the Standard Methods of Fire Tests of Building... knowledgeable, trained, and skilled in the safe evacuation of employees during emergency situations and in assisting in fire fighting operations. (f) Fire resistance means so resistant to fire that, for specified...
29 CFR 1926.155 - Definitions applicable to this subpart.
Code of Federal Regulations, 2010 CFR
2010-07-01
... part, fire resistance shall be determined by the Standard Methods of Fire Tests of Building... knowledgeable, trained, and skilled in the safe evacuation of employees during emergency situations and in assisting in fire fighting operations. (f) Fire resistance means so resistant to fire that, for specified...
The effect of smoke inhalation on lung function and airway responsiveness in wildland fire fighters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, D.; Tager, I.B.; Balmes, J.R.
1992-12-01
The current study was undertaken to evaluate the effect of smoke on forced expiratory volumes and airway responsiveness in wildland fire fighters during a season of active fire fighting. Sixty-three seasonal and full-time wildland fire fighters from five U.S. Department of Agriculture Forest Service (USDAFS) Hotshot crews in Northern California and Montana completed questionnaires, spirometry, and methacholine challenge testing before and after an active season of fire fighting in 1989. There were significant mean individual declines of 0.09, 0.15, and 0.44 L/s in postseason values of FVC, FEV1, and FEF25-75, respectively, compared with preseason values. There were no consistent significantmore » relationships between mean individual declines of the spirometric parameters and the covariates: sex, smoking history, history of asthma or allergies, years as a fire fighter, upper/lower respiratory symptoms, or membership in a particular Hotshot crew. There was a statistically significant increase in airway responsiveness when comparing preseason methacholine dose-response slopes (DRS) with postseason dose-response slopes (p = 0.02). The increase in airway responsiveness appeared to be greatest in fire fighters with a history of lower respiratory symptoms or asthma, but it was not related to smoking history. These data suggest that wildland fire fighting is associated with decreases in lung function and increases in airway responsiveness independent of a history of cigarette smoking. Our findings are consistent with the results of previous studies of municipal fire fighters.« less
Owen P. Cramer
1959-01-01
Hard-hitting fire-fighting crews and effective fire prevention held down this year's fire losses despite critical weather." Have you ever read such a statement and wondered how much of the apparently good record was really due to weather conditions?
Fire Safety. Managing School Facilities, Guide 6.
ERIC Educational Resources Information Center
Department for Education and Employment, London (England). Architects and Building Branch.
This booklet discusses how United Kingdom schools can manage fire safety and minimize the risk of fire. The guide examines what legislation school buildings must comply with and covers the major risks. It also describes training and evacuation procedures and provides guidance on fire precautions, alarm systems, fire fighting equipment, and escape…
Inflatable partition for fighting mine fires
Conti, Ronald S.; Lazzara, Charles P.
1995-01-01
The seal is a lightweight, inflatable, bag which may be inflated by a portable air generator and is used to seal a burning mine passage. A collapsible tube-like aperture extends through the seal and allows passage of high expansion foam through the seal in a feed tube. The foam fills the passageway and extinguishes the fire. In other embodiments, the feed tubes incorporate means to prevent collapse of the aperture. In these embodiments a shroud connects the feed tube to a foam generator. This seal allows creation of a high expansion foam fire fighting barrier even in upward sloping passages.
NASA Technical Reports Server (NTRS)
Boquist, C.
2004-01-01
This DVD includes animations of multisensor fire observations from the following satellite sources: Landsat, GOES, TOMS, Terra, QuikSCAT, and TRMM. Some of the animations are included in multiple versions of a short video presentation on the DVD which focuses on the Hayman, Rodeo-Chediski, and Biscuit fires during the 2002 North American fire season. In one version of the presentation, MODIS, TRMM, GOES, and QuikSCAT data are incorporated into the animations of these wildfires. These data products provided rain, wind, cloud, and aerosol data on the fires, and monitored the smoke and destruction created by them. Another presentation on the DVD consists of a panel discussion, in which experts from academia, NASA, and the U.S. Forest Service answer questions on the role of NASA in fighting forest fires, the role of the Terra satellite and its instruments, including the Moderate Resolution Imaging Spectroradiometer (MODIS), in fire fighting decision making, and the role of fire in the Earth's climate. The third section of the DVD features several animations of fires over the years 2001-2003, including animations of global and North American fires, and specific fires from 2003 in California, Washington, Montana, and Arizona.
Fight Fire with These Safety Strategies.
ERIC Educational Resources Information Center
Jackson, Lisa M.
1998-01-01
Provides expert guidelines on ways to keep schools and children safe from building fires, such as maintenance of exits for easy egress in emergencies, maintaining fire-protection systems, and utilizing evacuation planning and drilling. Highlights fire-safety ideas as part of school-building and renovation projects. (GR)
75 FR 3193 - Information Collection; Annual Wildfire Summary Report
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-20
... addressed to Tim Melchert, Fire and Aviation Management, National Interagency Fire Center, Forest Service... Forest Service State and Private Forestry Cooperative Fire Program. The program provides supplemental funding for State and local fire fighting agencies. The Forest Service works cooperatively with State and...
Dawson, Drew; Mayger, Katherine; Thomas, Matthew J W; Thompson, Kirrilly
2015-11-01
An increasing number and intensity of catastrophic fire events in Australia has led to increasing demands on a mainly volunteer fire-fighting workforce. Despite the increasing likelihood of fatigue in the emergency services environment, there is not yet a systematic, unified approach to fatigue management in fire agencies across Australia. Accordingly, the aim of this study was to identify informal strategies used in volunteer fire-fighting and examine how these strategies are transmitted across the workforce. Thirty experienced Australian volunteer fire-fighters were interviewed in August 2010. The study identified informal fatigue-management behaviours at the individual, team and brigade level that have evolved in fire-fighting environments and are regularly implemented. However, their purpose was not explicitly recognized as such. This apparent paradox - that fatigue proofing behaviours exist but that they are not openly understood as such - may well resolve a potential conflict between a culture of indefatigability in the emergency services sector and the frequent need to operate safely while fatigued. However, formal controls require fire-fighters and their organisations to acknowledge and accept their vulnerability. This suggests two important areas in which to improve formal fatigue risk management in the emergency services sector: (1) identifying and formalising tacit or informal fatigue coping strategies as legitimate elements of the fatigue risk management system; and (2) developing culturally appropriate techniques for systematically communicating fatigue levels to self and others. Copyright © 2015 Elsevier Ltd. All rights reserved.
FIRE SERVICE TRAINING, INSTRUCTOR'S MANUAL, BASIC COURSE.
ERIC Educational Resources Information Center
BERNDT, WILLIAM M.; AND OTHERS
INSTRUCTORS CAN USE THIS MANUAL IN CONDUCTING A 34-HOUR FIRE STATION OR TRAINING CENTER EXTENSION PROGRAM TO IMPROVE THE COMPETENCIES AND SKILLS OF LOCAL FIRE PERSONNEL IN THE SPECIALIZED FIELD OF FIRE SERVICE. IT WAS DEVELOPED BY A STATEWIDE COMMITTEE OF FIRE FIGHTING CONSULTANTS AND ADVISORY GROUPS. THE 26 TEACHING GUIDES PROVIDE INSTRUCTIONAL…
Fire hazard considerations for composites in vehicle design
NASA Technical Reports Server (NTRS)
Gordon, Rex B.
1994-01-01
Military ground vehicles fires are a significant cause of system loss, equipment damage, and crew injury in both combat and non-combat situations. During combat, the ability to successfully fight an internal fire, without losing fighting and mobility capabilities, is often the key to crew survival and mission success. In addition to enemy hits in combat, vehicle fires are initiated by electrical system failures, fuel line leaks, munitions mishaps and improper personnel actions. If not controlled, such fires can spread to other areas of the vehicle, causing extensive damage and the potential for personnel injury and death. The inherent fire safety characteristics (i.e. ignitability, compartments of these vehicles play a major roll in determining rather a newly started fire becomes a fizzle or a catastrophe. This paper addresses a systems approach to assuring optimum vehicle fire safety during the design phase of complex vehicle systems utilizing extensive uses of composites, plastic and related materials. It provides practical means for defining the potential fire hazard risks during a conceptual design phase, and criteria for the selection of composite materials based on its fire safety characteristics.
Mann Gulch fire: A race that couldn't be won
Richard C. Rothermel
1993-01-01
Describes the final 20 minutes of a smokejumper fire-fighting crew and the fire that overran 16 men as they were attempting to escape. The foreman and two firefighters escaped. Comparison with the behavior of a crew trapped by a fire in 1985 is described.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matthews, B.; Matthews, R.T.
Since Drake`s first oil well in 1859, well fires have been frequent and disastrous. Hardly a year has passed in over a century without a well fire somewhere in the world. In the 1920`s the classic method of fire fighting using explosives to starve the fire of oxygen was developed and it has been used extensively ever since. While explosives are still one of the most frequently used methods today, several other methods are used to supplement it where special conditions exist. Tunneling at an angle from a safe distance is used in some cases, especially where the fire ismore » too hot for a close approach on the ground surface. Pumping drilling muds into a well to plug it is another method that has been used successfully for some time. Diverter wells are occasionally used, and sometimes simply pumping enough water on a well fire is sufficient to extinguish it. Of course, prevention is always the best solution. Many advances in blow-out prevention devices have been developed in the last 50 years and the number of fires has been substantially reduced compared to the number of wells drilled. However, very little in new technology has been applied to oil well fire fighting in the 1960s, 1970s, or 1980s. Overall technological progress has accelerated tremendously in this period, of course, but new materials and equipment were not applied to this field for some reason. Saddam Hussein`s environmental holocaust in Kuwait changed that by causing many people throughout the world to focus their creative energy on more efficient oil well fire fighting methods.« less
ZrP nanoplates based fire-fighting foams stabilizer
NASA Astrophysics Data System (ADS)
Zhang, Lecheng; Cheng, Zhengdong; Li, Hai
2015-03-01
Firefighting foam, as a significant innovation in fire protection, greatly facilitates extinguishments for liquid pool fire. Recently, with developments in LNG industry, high-expansion firefighting foams are also used for extinguishing LNG fire or mitigating LNG leakage. Foam stabilizer, an ingredient in fire-fighting foam, stabilizes foam bubbles and maintains desired foam volume. Conventional foam stabilizers are organic molecules. In this work, we developed a inorganic based ZrP (Zr(HPO4)2 .H2O, Zirconium phosphate) plates functionalized as firefighting foam stabilizer, improving firefighting foam performance under harsh conditions. Several tests were conducted to illustrate performance. The mechanism for the foam stabilization is also proposed. Artie McFerrin Department of Chemical Engineering, Texas A&M University, College Station, TX 77843, USA. Mary Kay O'Connor Process Safety Center, Texas A&M University, College Station, TX, 77843-3122
The Wildland/Urban Interface in 2025
Gary O. Tokle
1987-01-01
In the year 2025, wildland fire fighting practices have improved significantly over the method employed during the late1900's. Improved methods for predicting severe fire weather conditions, the establishment of the North American Fire Coordination Center, and the utilization of foam products for both wildfire and structural fire control have significantly changed...
49 CFR 176.69 - General stowage requirements for hazardous materials.
Code of Federal Regulations, 2010 CFR
2010-10-01
... equipped with a fixed fire extinguishing and fire detection system, the freight containers or barges need... by paragraph (a) of this section if fire fighting equipment capable of reaching and piercing the..., their removal from a potentially dangerous situation, and the removal of packages in case of fire. (b...
A WSN-based tool for urban and industrial fire-fighting.
De San Bernabe Clemente, Alberto; Martínez-de Dios, José Ramiro; Ollero Baturone, Aníbal
2012-11-06
This paper describes a WSN tool to increase safety in urban and industrial fire-fighting activities. Unlike most approaches, we assume that there is no preexisting WSN in the building, which involves interesting advantages but imposes some constraints. The system integrates the following functionalities: fire monitoring, firefighter monitoring and dynamic escape path guiding. It also includes a robust localization method that employs RSSI-range models dynamically trained to cope with the peculiarities of the environment. The training and application stages of the method are applied simultaneously, resulting in significant adaptability. Besides simulations and laboratory tests, a prototype of the proposed system has been validated in close-to-operational conditions.
The Effect of Computer-Based Simulation Training on Fire Ground Incident Commander Decision Making
ERIC Educational Resources Information Center
Hall, Kurt A.
2010-01-01
Since the establishment of the first volunteer fire brigades in the United States, firefighters have lost their lives in fire fighting operations at emergency incidents and live-fire training activities. While there are various reasons for these firefighter deaths and injuries, the United States Fire Administration (2002) reported that many of…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cantrell, Kirk J; Liikala, Terry L; Strenge, Dennis L
PNNL conducted independent site evaluations for four sites at Fort Lewis, Washington, to determine their suitability for closure on behalf of the installation. These sites were recommended for ''No Further Action'' by previous investigators and included the Storm Water Outfalls/Industrial Waste Water Treatment Plant (IWTP), the Pesticide Rinse Area, the Old Fire Fighting Training Pit, and the Illicit PCB Dump Site.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cantrell, Kirk J.; Liikala, Terry L.; Strenge, Dennis L.
PNNL conducted independent site evaluations for four sites at Fort Lewis, Washington, to determine their suitability for closure on behalf of the installation. These sites were recommended for "No Further Action" by previous invesitgators and included the Storm Water Outfalls/Industrial Waste Water Treatment Plant (IWTP), the Pesticide Rinse Area, the Old Fire Fighting Training Pit, and the Illicit PCB Dump Site.
Individual Combatant’s Weapons Firing Algorithm Phase 1
2010-06-01
Z as in zebra...Drilis? 2 - 5 years ago More than 6 years ago 7. ~HOW~ z ~~:::: fire fights have you been In1 3-9 10 or more 8. Of those fights, what percentage were...34, ~ ’~-<’" ;-~/Nr,. ~ ~ "~t’ "X\\’ikJ ~ ,.’ \\1" ’: ’\\ Z ;J;l~~’i/’r.i\\ I " ,.. ..... ’-.-1 . , .. ,~ . \\\\ 1 ;C~"~~~~,~,, ~’",~"",~, ........... ~ f·
NASA helicopter helps fight fire at KSC
NASA Technical Reports Server (NTRS)
2000-01-01
A NASA helicopter drops water from a special '''bucket''' onto a small fire on Kennedy Space Center grounds. The site is between Kennedy Parkway North and the Indian River. The fire is one of many throughout Central Florida, which is suffering from drought.
STS-47 crew during fire fighting exercises at JSC's Fire Training Pit
NASA Technical Reports Server (NTRS)
1992-01-01
STS-47 Endeavour, Orbiter Vehicle (OV) 105, crewmembers line up along water hoses to extinguish a blaze in JSC's Fire Training Pit during fire fighting exercises. Manning the hose in the foreground are Payload Specialist Mamoru Mohri, holding the hose nozzle, backup Payload Specialist Takao Doi, Mission Specialist (MS) Jerome Apt, and Commander Robert L. Gibson, at rear. Lined up on the second hose are Pilot Curtis L. Brown, Jr, holding the hose nozzle, followed by MS N. Jan Davis, MS and Payload Commander (PLC) Mark C. Lee, and backup Payload Specialist Stan Koszelak. A veteran firefighter monitors the effort from a position between the two hoses. In the background, backup Payload Specialist Chiaki Naito-Mukai, donning gloves, and MS Mae C. Jemison look on. The Fire Training Pit is located across from the Gilruth Center Bldg 207. Mohri, Doi, and Mukai all represent Japan's National Space Development Agency (NASDA).
33 CFR 127.1307 - Emergency Manual.
Code of Federal Regulations, 2013 CFR
2013-07-01
....1505(a)(2). (b) The employee-emergency plan and fire-prevention plan required by OSHA in 29 CFR 1910.38... procedures for fighting a fire involving the LHG or its vapors; (2) A description of the emergency shutdown..., place, and use of the fire equipment required by § 127.1501(a) and of the portable fire extinguishers...
33 CFR 127.1307 - Emergency Manual.
Code of Federal Regulations, 2014 CFR
2014-07-01
....1505(a)(2). (b) The employee-emergency plan and fire-prevention plan required by OSHA in 29 CFR 1910.38... procedures for fighting a fire involving the LHG or its vapors; (2) A description of the emergency shutdown..., place, and use of the fire equipment required by § 127.1501(a) and of the portable fire extinguishers...
33 CFR 127.1307 - Emergency Manual.
Code of Federal Regulations, 2012 CFR
2012-07-01
....1505(a)(2). (b) The employee-emergency plan and fire-prevention plan required by OSHA in 29 CFR 1910.38... procedures for fighting a fire involving the LHG or its vapors; (2) A description of the emergency shutdown..., place, and use of the fire equipment required by § 127.1501(a) and of the portable fire extinguishers...
33 CFR 127.1307 - Emergency Manual.
Code of Federal Regulations, 2011 CFR
2011-07-01
....1505(a)(2). (b) The employee-emergency plan and fire-prevention plan required by OSHA in 29 CFR 1910.38... procedures for fighting a fire involving the LHG or its vapors; (2) A description of the emergency shutdown..., place, and use of the fire equipment required by § 127.1501(a) and of the portable fire extinguishers...
75 FR 35437 - Notice of Request for Extension of a Currently Approved Information Collection
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-22
... from construction of a fire station with fire fighting and rescue equipment to financing a 911 emergency system. These facilities are designed to provide fire protection and emergency rescue services to... for a currently approved information collection in support of the program for Fire and Rescue Loans...
An Educational Program Dealing with Fire Safety. Curriculum and Resource Guide.
ERIC Educational Resources Information Center
Rhode Island State Dept. of Education, Providence.
A series of activities for fire safety education in grades K-12 is presented. The document is organized into three parts: grades K-3; 4-6; and 7-12. Each activity is preceded by general and specific concepts to be stressed. Concepts for grades K-3 stress usefulness and types of fire, fire drills, the fire fighting profession, and the…
Szendro - type Integrated Vegetation Fire Management--Wildfire Management Program from Hungary
Ágoston Restás
2006-01-01
Szendrő Fire Department is located in the northeastern part of Hungary. The main task is to fight against wildfire and mitigate the impact of fire at the Aggtelek National Park -- which belongs to the UNESCO World Heritage list. Because of greater effectiveness, in 2004 the Fire Department started a project named Integrated Vegetation Fire Management (IVFM)....
DETERMINATION OF PERFLUOROCARBOXYLATES IN GROUNDWATER IMPACTED BY FIRE-FIGHTING ACTIVITY. (R821195)
Perfluorinated surfactants are used in aqueous film forming foam (AFFF)
formulations, which are used to extinguish hydrocarbon-fuel fires. Virtually
nothing is known about the occurrence of perfluorinated surfactants in the
environment, in particular, at fire-train...
ERIC Educational Resources Information Center
Spoor, Dana L.
1996-01-01
School districts are integrating security and life-safety systems into school buildings to protect students and property. This proactive approach includes sprinkler systems, fire alarms, and security systems that monitor door movement. Some school districts that are incorporating the latest life-safety technology are in Missouri, Ohio, California,…
33 CFR 145.05 - Classification of fire extinguishers.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Classification of fire... SECURITY (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES FIRE-FIGHTING EQUIPMENT § 145.05 Classification of....05(c)—Portable and Semiportable Extinguishers Classification Type Size Soda-acid and water, gallons...
78 FR 40089 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-03
.... The FS works cooperatively with State and local fire fighting agencies to support their fire... fires and acres burned on State and private land by cause, such as lightning, campfires, smoking, debris burning, arson, equipment, railroads, children and miscellaneous activities. Information will be shared...
Future Role of Fire Service in Homeland Security
2008-09-01
to fight terrorism (Office of the President, 2007). In his letter to Americans in which he introduced the NSHS, President Bush explained that...structures struggling to fight non-state terrorists operating without clearly defined leadership. Furthermore, according to James R. Locker III...learned from World War II and designed to fight the Cold War. Current exposure to terrorism and terrorist cells is vastly different 16 from
A WSN-Based Tool for Urban and Industrial Fire-Fighting
De San Bernabe Clemente, Alberto; Dios, José Ramiro Martínez-de; Baturone, Aníbal Ollero
2012-01-01
This paper describes a WSN tool to increase safety in urban and industrial fire-fighting activities. Unlike most approaches, we assume that there is no preexisting WSN in the building, which involves interesting advantages but imposes some constraints. The system integrates the following functionalities: fire monitoring, firefighter monitoring and dynamic escape path guiding. It also includes a robust localization method that employs RSSI-range models dynamically trained to cope with the peculiarities of the environment. The training and application stages of the method are applied simultaneously, resulting in significant adaptability. Besides simulations and laboratory tests, a prototype of the proposed system has been validated in close-to-operational conditions. PMID:23202198
A portable W-band radar system for enhancement of infrared vision in fire fighting operations
NASA Astrophysics Data System (ADS)
Klenner, Mathias; Zech, Christian; Hülsmann, Axel; Kühn, Jutta; Schlechtweg, Michael; Hahmann, Konstantin; Kleiner, Bernhard; Ulrich, Michael; Ambacher, Oliver
2016-10-01
In this paper, we present a millimeter wave radar system which will enhance the performance of infrared cameras used for fire-fighting applications. The radar module is compact and lightweight such that the system can be combined with inertial sensors and integrated in a hand-held infrared camera. This allows for precise distance measurements in harsh environmental conditions, such as tunnel or industrial fires, where optical sensors are unreliable or fail. We discuss the design of the RF front-end, the antenna and a quasi-optical lens for beam shaping as well as signal processing and demonstrate the performance of the system by in situ measurements in a smoke filled environment.
Low Level Impacts on Fire Evolution in the Mack Lake and Other Severe Wildfires
Joseph J. Charney; Xindi Bian; Brian E. Potter; Warren E. Heilman
2003-01-01
The 2000 fire season brought to the forefront the issue of severe wildland fires in the United States. To address the need for new research and for the development of predictive tools for managing wildland fires, Congress allocated funding under the National Fire Plan (NFP) to better equip government agencies to fight and study forest fires. As part of the NFP research...
An integer programming model to optimize resource allocation for wildfire containment.
Geoffrey H. Donovan; Douglas B. Rideout
2003-01-01
Determining the specific mix of fire-fighting resources for a given fire is a necessary condition for identifying the minimum of the Cost Plus Net Value Change (C+NVC) function. Current wildland fire management models may not reliably do so. The problem of identifying the most efficient wildland fire organization is characterized mathematically using integer-...
Advanced Catalytic Enzyme System (ACES) - Dual Use Capabilities
2003-07-01
Novozymes A/S (Bagsvaerd, Denmark) with activity against both cells and spores, and a bacteriophage enzyme (PlyG Lysin) that is specific for B. anthracis... Novozymes ), Lysozyme (commercial) Buffer: Ammonium carbonate Fire-Fighting Components: ColdFire®, Fire Choke® or an equivalent Class A foam The
33 CFR 145.05 - Classification of fire extinguishers.
Code of Federal Regulations, 2014 CFR
2014-07-01
... SECURITY (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES FIRE-FIGHTING EQUIPMENT § 145.05 Classification of... means so that all portions of the space concerned may be covered. Examples of size graduations for some...
33 CFR 145.05 - Classification of fire extinguishers.
Code of Federal Regulations, 2012 CFR
2012-07-01
... SECURITY (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES FIRE-FIGHTING EQUIPMENT § 145.05 Classification of... means so that all portions of the space concerned may be covered. Examples of size graduations for some...
33 CFR 145.05 - Classification of fire extinguishers.
Code of Federal Regulations, 2013 CFR
2013-07-01
... SECURITY (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES FIRE-FIGHTING EQUIPMENT § 145.05 Classification of... means so that all portions of the space concerned may be covered. Examples of size graduations for some...
Defense.gov Special Report: California Wildfires
Fight California Wildfires U.S. Marines and aircraft with 3rd Marine Aircraft Wing and fire crews on Wildfires CDC Emergency Preparedness - Wildfires Current California Fire Information (CA.gov) Official Camp
33 CFR 401.94 - Keeping copies of regulations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... duplicated set of the Ship's Fire Control Plans shall be permanently stored in a prominently marked weather-tight enclosure outside the deckhouse for the assistance of shore-side fire-fighting personnel. [70 FR...
33 CFR 401.94 - Keeping copies of regulations.
Code of Federal Regulations, 2014 CFR
2014-07-01
... duplicated set of the Ship's Fire Control Plans shall be permanently stored in a prominently marked weather-tight enclosure outside the deckhouse for the assistance of shore-side fire-fighting personnel. [70 FR...
25 CFR 163.28 - Fire management measures.
Code of Federal Regulations, 2010 CFR
2010-04-01
... wildfire protection needs and extinguish forest or range fires on Indian land. No expenses for fighting a... 25 Indians 1 2010-04-01 2010-04-01 false Fire management measures. 163.28 Section 163.28 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR LAND AND WATER GENERAL FORESTRY REGULATIONS Forest...
U.S. Coast Guard cutter personnel on Sweetbriar train their fire ...
U.S. Coast Guard cutter personnel on Sweetbriar train their fire hoses on a burning pleasure boat in an Alaskan harbor. A U.S. Coast Guard rigid-hull inflatable helps with the fire-fighting effort - U.S. Coast Guard Cutter SWEETBRIER, Cordova, Valdez-Cordova Census Area, AK
DefenseLink Feature: Military Helps Fight California Wildfires
planes dropping fire retardant on wildfires in southern California face hazards and challenges unique to ' * Sailors Help Victims in Need * Bush Pledges Military Will Continue to Provide Fire Aid | Video
Water Supply Systems For Aircraft Fire And Rescue Protection
DOT National Transportation Integrated Search
1995-01-01
This Advisory Circular (AC) provides guidance for the selection : of a water source and standards for the design of a distribution system to : support aircraft rescue and fire fighting (ARFF) service operations on : airports.
NASA Technical Reports Server (NTRS)
Mattingly, G. S.
1974-01-01
The research relating to airborne fire fighting systems is reviewed to provide NASA/Langley Research Center with current information on the use of aircraft in forest fire operations, and to identify research requirements for future operations. A literature survey, interview of forest fire service personnel, analysis and synthesis of data from research reports and independent conclusions, and recommendations for future NASA-LRC programs are included.
NASA Astrophysics Data System (ADS)
Kachanov, I. V.; Veremenyuk, V. V.; Karpenchuk, I. V.; Pavlyukov, S. Yu.
2013-05-01
The mechanics of movement of a liquid in the diffuser of the injector of an automatic extinguishing installation with preaeration of the fire-fighting substance was theoretically investigated. An integral solution of the equation for movement of the preaerated fire-fighting gas-liquid mixture in the indicated diffuser has been obtained. A mathematical model of two-phase liquid flow in this diffuser, which allows one to calculate the distribution of the average pressure in the diffuser along its length and to determine the loss in this pressure, has been developed. This model can be used for designing the output region of a hydraulic system with a hydrodynamic drag providing the operation of its injector in a definite regime.
Applicability of ISO 16697 Data to Spacecraft Fire Fighting Strategies
NASA Technical Reports Server (NTRS)
Hirsch, David B.; Beeson, Harold D.
2012-01-01
Presentation Agenda: (1) Selected variables affecting oxygen consumption during spacecraft fires, (2) General overview of ISO 16697, (3) Estimated amounts of material consumed during combustion in typical ISS enclosures, (4) Discussion on potential applications.
When the Fire's Out: Learning from Adversity.
ERIC Educational Resources Information Center
Holden, Tom
1997-01-01
After a $7 million arson fire destroyed part of a Virginia Beach high school, about 1,200 students were temporarily relocated to a refurbished former mini-mall, and a 16-month recovery project was initiated. The new design improved library and art facilities. School officials have since learned to fight fire with simple precautions, such as…
New fire-fighting water bucket is lifted by helicopter
NASA Technical Reports Server (NTRS)
2000-01-01
A NASA helicopter lifts a high-impact-resistant flexible plastic bucket that will be used for fire protection on property and buildings at Kennedy Space Center. Known as the 'Bambi' bucket, the 324-gallon container will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.
46 CFR 153.975 - Preparation for cargo transfer.
Code of Federal Regulations, 2010 CFR
2010-10-01
... system to have a fire protection system. (b) Any electrical bonding of the tankship to the transfer... plugged. (m) Smoking is limited to safe places. (n) Fire fighting and safety equipment is ready. (o) He is... or continue cargo transfer unless the following conditions are met: (a) No fires or open flames are...
Joseph J. Charney; Xindi Bian; Brian E. Potter; Warren E. Heilman
2003-01-01
The 2000 fire season brought to the forefront the issue of severe wildland fires in the United States. To address the need for new research and for the development of predictive tools for the management of wildland fires, Congress allocated funding under the National Fire Plan (NFP) to better equip government agencies to fight and study forest fires. As part of the NFP...
John J. Qu; Xianjun Hao; Ruixin Yang; Swarvanu Dasgupta; Sanjeeb Bhoi; Menas Kafatos
1999-01-01
Fire eniissions, smoke dispersiotl. ancl air quality are very important for fire fighting and planing of prescribed burning. BlueskyRATNS (BSR) is a comprehenisive and state-of-the-art Decision Support System (DSS) for fire managers and air quality managers to plan fiiels treatments and support state air qiiality smoke regulatory actions, especially related to...
New fire-fighting water bucket releases its water for a demonstration
NASA Technical Reports Server (NTRS)
2000-01-01
A NASA helicopter releases 324 gallons of water onto a building in a simulated fire control demonstration. The high-impact- resistant flexible plastic bucket will be used for fire protection on property and buildings at Kennedy Space Center. Known as the 'Bambi' bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.
Fighting the Fire in Our Own House: How Poor Decisions are Smoldering Within the U.S. Fire Service
Additionally, a second recommendation suggests incorporating an anonymous near-miss reporting system to identify workplace incidents that fall short of an accident, but nonetheless contain pertinent educational information.
30 CFR 75.1908 - Nonpermissible diesel-powered equipment; categories.
Code of Federal Regulations, 2013 CFR
2013-07-01
... the mine fire fighting and evacuation plan under § 75.1502. [61 FR 55527, Oct. 25, 1996; 70 FR 36347... such machine or device, which job site is occupied by a miner. (d) Diesel-powered ambulances and fire...
2000-06-02
A NASA helicopter takes off to bring water to fight a small fire on Kennedy Space Center grounds. The site is between Kennedy Parkway North and the Indian River. The fire is one of many throughout Central Florida, which is suffering from drought
2000-06-02
A NASA helicopter takes off to bring water to fight a small fire on Kennedy Space Center grounds. The site is between Kennedy Parkway North and the Indian River. The fire is one of many throughout Central Florida, which is suffering from drought
New fire-fighting water bucket is readied for a demonstration
NASA Technical Reports Server (NTRS)
2000-01-01
Workers attach a high-impact-resistant flexible plastic bucket to a NASA helicopter. Holding 324 gallons of water, it will be used for fire protection on property and buildings at Kennedy Space Center. Known as the 'Bambi' bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.
New fire-fighting water bucket is filled for demonstration
NASA Technical Reports Server (NTRS)
2000-01-01
- A NASA helicopter hovers over the water while a high-impact- resistant flexible plastic bucket fills. The 324-gallon container will be used for fire protection on property and buildings at Kennedy Space Center. Known as the 'Bambi' bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.
New fire-fighting water bucket is lifted from water for a demonstration
NASA Technical Reports Server (NTRS)
2000-01-01
A NASA helicopter lifts a high-impact-resistant flexible plastic bucket filled with water. The container will be used for fire protection on property and buildings at Kennedy Space Center.. Known as the 'Bambi' bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.
NASA Technical Reports Server (NTRS)
1984-01-01
Firefighting trainees conduct fire control exercises using a prototype simulator known as the Emergency Management Computer Aided Training System (EMCAT). Developed by Marshall Space Flight Center (MFS) in response to a request from the Huntsville (AL) Fire Department, EMCAT enables a trainee to assume the role of fireground commander and make quick decisions on best use of his fire fighting personnel and equipment.
Integrated Personal Protective Equipment Standards Support Model
2008-04-01
traditional SCBA showed that the distribution of the weight is important as well. Twelve firefighters performed simulated fire -fighting and rescue exercises...respiratory equipment standards and five National Fire Protection Association (NFPA) protective suit, clothing, and respirator standards. The...respirators. The clothing standards were for protective ensembles for urban search and rescue operations, open circuit SCBA for fire and emergency
Proceedings of the symposium on fire and watershed management
Neil H. Berg
1989-01-01
Wildfires have affected the landscape since the dawn of time and will continue to do so for the foreseeable future. Policies and practices in response to fire have varied, however, contingent upon a complex mix of values and attitudes overlaid by the technical acumen available to both "fight" the fire and reclaim the land afterwards.
2000-08-08
A NASA helicopter flies over fire-fighting equipment and personnel in order to drop its load of water on a wildfire at KSC. Before being extinguished, the fire burned about 20 acres at a site near gate 2C on Kennedy Parkway North (route 3)
2000-08-08
A NASA helicopter flies over fire-fighting equipment and personnel in order to drop its load of water on a wildfire at KSC. Before being extinguished, the fire burned about 20 acres at a site near gate 2C on Kennedy Parkway North (route 3)
Fire/security staff member instructs STS-29 crew on fire extinguisher usage
NASA Technical Reports Server (NTRS)
1988-01-01
STS-29 Discovery, Orbiter Vehicle (OV) 103, crewmembers are trained in procedures to follow in the event of a fire. Here, the crew is briefed on the correct handling of the fire extinguisher by Robert Fife (far left) of NASA's fire / security staff. Pictured, left to right are Pilot John E. Blaha, Commander Michael L. Coats, Mission Specialist (MS) Robert C. Springer, MS James F. Buchli, and MS James P. Bagian. The in fire fighting training took place at JSC's fire training pit across from the Gilruth Center Bldg 207.
NASA Astrophysics Data System (ADS)
Aricak, Burak; Kucuk, Omer; Enez, Korhan
2014-01-01
Fighting forest fires not only depends on the forest type, topography, and weather conditions, but is also closely related to the technical properties of fire-fighting equipment. Firefighting is an important part of fire management planning. However, because of the complex nature of forests, creating thematic layers to generate potential fire risk maps is difficult. The use of remote sensing data has become an efficient method for the discrete classification of potential fire risks. The study was located in the Central District of the Kastamonu Regional Forest Directorate, covering an area of 24,320 ha, 15,685 ha of which is forested. On the basis of stand age, crown closure, and tree species, the sizes and distributions of potential fire risk zones within the study area were determined using high-resolution GeoEye satellite imagery and geographical information system data. The status of pumper truck intervention in zones with high fire risk and the sufficiency of existing forest roads within an existing forest network were discussed based on combustible matter characteristics. Pumper truck intervention was 83% for high-risk zones, 79% for medium-risk zones, and 78% for low-risk zones. A pumper truck intervention area map along existing roads was also created.
Gragnani, Alfredo; de Oliveira, Andrea Fernandes; Boro, Daniel; Pham, Tam N; Ferreira, Lydia Masako
2017-03-01
A major fire occurred on January 27, 2013, at 02:30 at Kiss nightclub in the city of Santa Maria, State of Rio Grande do Sul, in Southern Brazil. In this retrospective report, we aimed to describe the nightclub fire event, its immediate consequences, and evaluated its impact on legislation. Our objective was to disseminate the lessons we learned from this large-scale nightclub fire disaster. We conducted a literature review in PubMed and Lilacs database from 2013 to 2015 related to the nightclub Kiss, Santa Maria, fire, burns, and similar events worldwide over the past 15 years. We searched in the general press and online media information sites, and seeking legislation about this topic at the federal level in Brazil. We reported on the legislation changes that resulted from this nightclub fire. Current federal legislation on fire prevention and the scope of public safety, including night clubs and discos, states is the duty of the state and everyone's responsibility, pursuant to Article 144 of the Federal Constitution of Brazil. Thus, the federal union, individual states and municipalities have the power to legislate on fire prevention, and especially to ensure the security of the population. A state law called "Law Kiss", was passed in 2014, establishing standards on safety, prevention and protection against fire in buildings and areas of fire risk in the state of Rio Grande do Sul. On a national level, a law of prevention and fire fighting in Brazil was also drafted after the Santa Maria disaster (Law project no. 4923, 2013). Currently, this bill is still awaiting sanction before it can take effect. As we push for enactment of the national law of prevention and fire fighting in Brazil, we will continue emphasizing fire prevention, fire protection, fire fighting, means of escape and proper management. All similar events in this and other countries remind us that similar tragedies may occur anywhere, and that the analysis of facts, previous mistakes, during and after the incident are crucial to our understanding, and will help us lessen the chance of future occurrences. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.
Study on the generation of perfluorooctane sulfonate from the aqueous film-forming foam.
Kishi, Takahiro; Arai, Mitsuru
2008-11-15
Perfluorooctane sulfonate (C(8)HF(17)SO(3)) and perfluorooctane acid (C(8)HF(15)O(2)) are artificial chemicals and have been used all over the world, mainly as water repellent agents, fluorochemical surfactants, coating agents, etc. However, perfluorooctane sulfonate and perfluorooctane acid are environmental contaminants because of their stability, bio-accumulativeness, and long-term persistence in the ecological environment. At the present day, they are diffused all over the world. Lately, this diffusion is viewed with suspicion and there is a movement towards their restriction, even if the environmental fate of them is still under investigation. Fluorochemical surfactants are key compounds in the aqueous film-forming foam (AFFF) formulations. AFFFs are used for massive conflagration such as industrial fire and petroleum fire because of their efficient fire control. On the other hand, a lot of AFFFs are used in case of massive conflagration and most of them enter ocean and groundwater. Actually, perfluorooctane sulfonate and perfluorooctane sulfonate related substances were detected from the fire-fighting facility of US forces. Therefore, there is the possibility of generating perfluorooctane sulfonate and perfluorooctane sulfonate related substances from fluorochemical surfactants in the AFFFs. In this study, activated sludge added AFFF were analyzed for perfluorooctane sulfonate and perfluorooctane acid with time. And the perfluorooctane sulfonate was directly detected after 2 days using LC-MS. This shows that AFFF can be decomposed perfluorooctane sulfonate by microorganisms easily. However, perfluorooctane sulfonate would not decompose at all. Additionally, activated sludge added N-polyoxyethylene-N-propyl perfluorooctane sulfonamide which is one of the fluorochemical surfactants used in the AFFF was analyzed for perfluorooctane sulfonate and perfluorooctane acid with time and the perfluorooctane sulfonate was detected too.
30 CFR 57.4200 - General requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Equipment § 57.4200 General requirements. (a) For fighting fires that could endanger...
30 CFR 56.4200 - General requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Equipment § 56.4200 General requirements. (a) For fighting fires that could endanger...
2000-08-08
A NASA helicopter dips its fire-fighting bucket into the river to pick up and deliver a cargo of water to a wildfire at KSC. Before being extinguished, the fire burned about 20 acres at a site near gate 2C on Kennedy Parkway North (route 3)
2000-08-08
A NASA helicopter dips its fire-fighting bucket into the river to pick up and deliver a cargo of water to a wildfire at KSC. Before being extinguished, the fire burned about 20 acres at a site near gate 2C on Kennedy Parkway North (route 3)
NASA helicopter helps fight brush fire at KSC
NASA Technical Reports Server (NTRS)
2000-01-01
A NASA helicopter flies toward the source of the smoke to drop its load of water on a wildfire at KSC. Before being extinguished, the fire burned about 20 acres at a site near gate 2C on Kennedy Parkway North (route 3).
46 CFR 12.05-3 - General requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... applicant must: (1) Be at least 18 years of age; (2) Pass the prescribed physical and medical examination in... § 12.01-3). (2) Fire prevention and fire-fighting as set out in table A-VI/1-2 of the STCW Code. (3...
46 CFR 12.05-3 - General requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... applicant must: (1) Be at least 18 years of age; (2) Pass the prescribed physical and medical examination in... § 12.01-3). (2) Fire prevention and fire-fighting as set out in table A-VI/1-2 of the STCW Code. (3...
48 CFR 452.236-77 - Emergency Response.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Response. As prescribed in 436.577, the following clause may be used in Forest Service construction contracts: Emergency Response (NOV 1996) (a) Contractor's Responsibility for Fire Fighting. (1) The..., Equipment, Utilities, and Improvements, shall immediately extinguish all fires on the work site other than...
48 CFR 452.236-77 - Emergency Response.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Response. As prescribed in 436.577, the following clause may be used in Forest Service construction contracts: Emergency Response (NOV 1996) (a) Contractor's Responsibility for Fire Fighting. (1) The..., Equipment, Utilities, and Improvements, shall immediately extinguish all fires on the work site other than...
48 CFR 452.236-77 - Emergency Response.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Response. As prescribed in 436.577, the following clause may be used in Forest Service construction contracts: Emergency Response (NOV 1996) (a) Contractor's Responsibility for Fire Fighting. (1) The..., Equipment, Utilities, and Improvements, shall immediately extinguish all fires on the work site other than...
48 CFR 452.236-77 - Emergency Response.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Response. As prescribed in 436.577, the following clause may be used in Forest Service construction contracts: Emergency Response (NOV 1996) (a) Contractor's Responsibility for Fire Fighting. (1) The..., Equipment, Utilities, and Improvements, shall immediately extinguish all fires on the work site other than...
48 CFR 452.236-77 - Emergency Response.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Response. As prescribed in 436.577, the following clause may be used in Forest Service construction contracts: Emergency Response (NOV 1996) (a) Contractor's Responsibility for Fire Fighting. (1) The..., Equipment, Utilities, and Improvements, shall immediately extinguish all fires on the work site other than...
Levine, A D; Libelo, E L; Bugna, G; Shelley, T; Mayfield, H; Stauffer, T B
1997-12-22
The biogeochemistry of the natural attenuation of petroleum-contaminated ground water was investigated in a field study. The focus of the study was a fire training site located on Tyndall Air Force Base in Florida. The site has been used by the Air Force for approximately 11 years in fire fighting exercises. An on-site above-ground tank of JP-4 provided fuel for setting controlled fires for the exercises. Various amounts of water and aqueous film forming foams (AFFF) were applied to extinguish the fires. The sources of contamination included leaks from pipelines transporting the fuel, leaks from an oil/water separator and runoff and percolation from the fire fighting activities. Previous investigations had identified jet fuel contamination at the site, however, no active remediation efforts have been conducted to date. The goal of this study was to use biogeochemical monitoring data to delineate redox zones within the site and to identify evidence of natural attenuation of JP-4 contamination. In addition to identifying several hydrocarbon metabolites, fluorinated surfactants (AFFF) were detected down-gradient of the hydrocarbon plume.
Building systems and smoke control
NASA Astrophysics Data System (ADS)
Kawagoe, K.; Wakamatsu, T.; Morishita, Y.; Yamana, T.
The cost effectiveness of different approaches to fire prevention - sprinklers and detectors, increased use of smoke control devices, increased flammability standards, increased public education, increase fire prevention efforts, increased public fire services, etc. - need to be studied further as a guide to determining the emphasis appropriate for each. It is clear that detectors and sprinklers are making a difference in the fight to reduce fire losses. With continued effort the detectors' and sprinklers' full potential for saving lives and property from fire can be realized.
Stennis acquires new ladder truck
2009-10-20
The Stennis Space Center Fire Department added to its fire-fighting capabilities with acquisition of a new emergency response vehicle, Ladder-1, for use on-site. The E-One HP78 Aerial Truck is a combination aerial ladder and fire suppression unit and is designed with the latest safety technology. Featuring a 78-foot ladder and a pumping capability of 1,500 gallons per minute, the new truck provides firefighters with a tremendous rescue and fire suppression tool, Stennis Fire Chief Clark Smith said.
Fire fighting and its influence on the body.
Rossi, René
2003-08-15
Working conditions for fire fighters can be described according to the environment temperature and the incident radiant heat flux. Measurements for this study in buildings for fire fighting training have shown that fire fighters are typically exposed to radiant heat fluxes of between 5 and 10 kWm(-2) during this kind of exercise. The heat load can nevertheless be much higher. In one case, 42 kWm(-2) was measured. The temperatures reached between 100 and 190 degrees C at 1 m above ground, going up to 278 degrees C in one case. Human trials have been performed with 17 fire fighters. After exercises (about 15 min) in a heated room, the mean core temperature of the fire fighters rose by 0.6 degrees C with a surrounding temperature of 31 degrees C and 1.0 degrees C with 38 degrees C. The sweat production varied from 0.7 to 2.1 lh(-1); 16% to 45% of sweat remained in the clothing layers. During the exercises in the training buildings, a mean of 48 degrees C has been measured between fire fighters' clothing and workwear. These conditions lead to an increase of the relative humidity in all the jackets up to 100%. When the fire fighters came out of the fire, the humidity remained at this level in the PVC coated jackets while it was in some cases strongly reduced in breathable jackets.
David T. Butry
2009-01-01
This paper examines the effect wildfire mitigation has on broad-scale wildfire behavior. Each year, hundreds of million of dollars are spent on fire suppression and fuels management applications, yet little is known, quantitatively, of the returns to these programs in terms of their impact on wildfire extent and intensity. This is especially true when considering that...
Fighting forest fires in Brazil
José Carlos Mendes de Morais
2013-01-01
Fire has been used in Brazil for many years, but the increased use of this tool, combined with natural events and the presence of large forest and agricultural areas, has led to a significant jump in the number of forest fires, most of them caused by accident. To optimize existing resources and to cope with growing demand, action levels were adopted according to the...
ERIC Educational Resources Information Center
Dade County Public Schools, Miami, FL.
This document presents an outline for a 135-hour course designed to familiarize the student with manipulative skills and theoretical knowledge concerning aircraft instrument systems like major flight and engine instruments; fire protection and fire fighting systems; warning systems and navigation systems; aircraft cabin control systems, such as…
Celebrating Ten Years. Foundation for Individual Rights in Education Annual Report, 2009
ERIC Educational Resources Information Center
Foundation for Individual Rights in Education (NJ1), 2009
2009-01-01
This paper presents the annual report of the Foundation for Individual Rights in Education (FIRE) for 2009. The year 2009 was momentous for FIRE, for it marked its tenth anniversary. In the last decade, FIRE has been remarkably successful at fighting to secure basic rights of free speech and conscience on college campuses. It has fought for…
New fire-fighting water bucket releases its load for a demonstration.
NASA Technical Reports Server (NTRS)
2000-01-01
A NASA helicopter releases the contents of the high-impact- resistant flexible plastic bucket it holds. The 324-gallon container will be used for fire protection on property and buildings at Kennedy Space Center. Known as the 'Bambi' bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.
NASA Technical Reports Server (NTRS)
2002-01-01
This photograph taken from the International Space Station on June 7, 2002, shows the Copper Fire burning in the hills outside Los Angeles. Astronauts use a variety of lenses and look angles as their orbits pass over wildfires to document the long-distance movements of smoke from the fires as well as details of the burning areas. This image clearly illustrates the difficult, rugged terrain that firefighters must face when fighting these wildland fires.
Richard D. Reitz
2003-01-01
The old model of individual homeowners and neighborhoods depending solely on government provided fire fighting resources is gone. Recent wildland fires have demonstrated that community firefighting resources are easily outpaced when multiple structures are burning simultaneously. The cure is to move most structure protection responsibility to the homeowner and...
Colleges Fight Fire With Electronics.
ERIC Educational Resources Information Center
College & University Business, 1968
1968-01-01
Description of various electronic fire detection and alarm systems is presented. Explanation of detective systems includes--(1) fixed-temperature and rate-of-rise heat sensitive devices, (2) smoke detective devices, (3) ionization systems, and (4) infrared and ultraviolet radiation devices. Each system type is evaluated in terms of operation,…
25 CFR 163.28 - Fire management measures.
Code of Federal Regulations, 2011 CFR
2011-04-01
... wildfire protection needs and extinguish forest or range fires on Indian land. No expenses for fighting a... are currently in use by public and private wildfire protection agencies adjacent to Indian... mutual aid in wildfire protection. This section does not apply to the rendering of emergency aid, or...
25 CFR 163.28 - Fire management measures.
Code of Federal Regulations, 2013 CFR
2013-04-01
... wildfire protection needs and extinguish forest or range fires on Indian land. No expenses for fighting a... are currently in use by public and private wildfire protection agencies adjacent to Indian... mutual aid in wildfire protection. This section does not apply to the rendering of emergency aid, or...
25 CFR 163.28 - Fire management measures.
Code of Federal Regulations, 2012 CFR
2012-04-01
... wildfire protection needs and extinguish forest or range fires on Indian land. No expenses for fighting a... are currently in use by public and private wildfire protection agencies adjacent to Indian... mutual aid in wildfire protection. This section does not apply to the rendering of emergency aid, or...
25 CFR 163.28 - Fire management measures.
Code of Federal Regulations, 2014 CFR
2014-04-01
... wildfire protection needs and extinguish forest or range fires on Indian land. No expenses for fighting a... are currently in use by public and private wildfire protection agencies adjacent to Indian... mutual aid in wildfire protection. This section does not apply to the rendering of emergency aid, or...
Medical evaluation of fire fighters: How fit are they for duty?
Davis, P O; Biersner, R J; Barnard, R J; Schamadan, J
1982-08-01
Aside from the obvious dangers to life and limb associated with the job, fire fighting subjects the body to environmental and physical stressors that can adversely affect various systems. In fact, the effects of these stressors on the cardiovascular system have made coronary heart disease a greater killer among fire fighters than among other occupational groups. The approach to medical evaluation of fire fighters presented here is based on an appreciation of these stressors.
46 CFR 167.45-40 - Fire-fighting equipment on nautical school ships using oil as fuel.
Code of Federal Regulations, 2011 CFR
2011-10-01
... following type and character: (a) In each boiler room and in each of the machinery spaces of a nautical... approved fire extinguishers of the foam type of not less than 9.5 liters (21/2 gallons) each or 2 or more approved fire extinguishers of the carbon dioxide type of not less than 33 kilograms (15 pounds) each must...
46 CFR 167.45-40 - Fire-fighting equipment on nautical school ships using oil as fuel.
Code of Federal Regulations, 2010 CFR
2010-10-01
... following type and character: (a) In each boiler room and in each of the machinery spaces of a nautical... approved fire extinguishers of the foam type of not less than 9.5 liters (21/2 gallons) each or 2 or more approved fire extinguishers of the carbon dioxide type of not less than 33 kilograms (15 pounds) each must...
Classical biological control of invasive species: fighting fire with fire
USDA-ARS?s Scientific Manuscript database
Invasive species cost the US over $130 billion in losses and control costs every year. Exotic insects, weeds and pathogens are the primary invaders that frequently move across continents, exploding in numbers in areas where they have been newly introduced. There are many reasons that these pests r...
14 CFR 25.1439 - Protective breathing equipment.
Code of Federal Regulations, 2014 CFR
2014-01-01
... breathing equipment must be installed for the use of appropriate crewmembers for fighting fires in... dioxide, and other harmful gases while on flight deck duty or while combating fires. (2) The equipment... considered to be of 15-minute duration at the prescribed altitude and minute volume. If a continuous flow...
14 CFR 25.1439 - Protective breathing equipment.
Code of Federal Regulations, 2013 CFR
2013-01-01
... breathing equipment must be installed for the use of appropriate crewmembers for fighting fires in... dioxide, and other harmful gases while on flight deck duty or while combating fires. (2) The equipment... considered to be of 15-minute duration at the prescribed altitude and minute volume. If a continuous flow...
NASA Astrophysics Data System (ADS)
Romagnoli, E.; Barboni, T.; Santoni, P.-A.; Chiaramonti, N.
2014-05-01
Prescribed burning represents a serious threat to personnel fighting fires due to smoke inhalation. The aim of this study was to investigate exposure by foresters to smoke from prescribed burning, focusing on exposure to volatile organic compounds (VOCs). The methodology for smoke sampling was first evaluated. Potentially dangerous compounds were identified among the VOCs emitted by smoke fires at four prescribed burning plots located around Corsica. The measured mass concentrations for several toxic VOCs were generally higher than those measured in previous studies due to the experimental framework (short sampling distance between the foresters and the flame, low combustion, wet vegetation). In particular, benzene, phenol and furfural exceeded the legal short-term exposure limits published in Europe and/or the United States. Other VOCs such as toluene, ethybenzene or styrene remained below the exposure limits. In conclusion, clear and necessary recommendations were made for protection of personnel involved in fighting fires.
Fire research publications, 1983
NASA Astrophysics Data System (ADS)
Jason, N. H.
1984-04-01
Approximately 130 articles are cited addressing topics in fire fighting and prevention, combustion physics, and fire related hazards. Only publications prepared by members of the Center for Fire Research (CFR), by other National Bureau of Standards (NBS) personnel for CFR, or by external laboratories under contract or grant from the CFR are cited. For documents that are available for purchase from either the Government Printing Office (GPO) or the National Technical Information Service (NTIS), the specific order number has been included in the citation.
Crystal S. Stonesifer; Dave Calkin; Matthew P. Thompson; Keith D. Stockmann
2016-01-01
Large airtanker use is widespread in wildfire suppression in the United States. The current approach to nationally dispatching the fleet of federal contract airtankers relies on filling requests for airtankers to achieve suppression objectives identified by fire managers at the incident level. In general, demand is met if resources are available, and the...
2008-07-14
California Governor Arnold Schwarzenegger during a press briefing following a visit to Ames Earth Science Division for a briefing by Steve Hipskind on NASA Ames remote sensing fire fighting efforts. Also shown left to right, Mike Freilich, Director, NASA Earth Sceinces Division, Steve Hipskind, Pete Worden, Governor Schwarzenegger, Chief Del Walters, Assistant Region Fire Chief, California Department of Forestry and Fire Protection, Tom Maruyama, Deputy Director, Office of Emergency Services
Acute health effects among firefighters exposed to a polyvinyl chloride (PVC) fire
DOE Office of Scientific and Technical Information (OSTI.GOV)
Markowitz, J.S.; Gutterman, E.M.; Schwartz, S.
1989-05-01
Firefighters are frequently being called on to fight fires that are chemical in nature. In the aftermath of a chemical fire in Plainfield, New Jersey on March 20-21, 1985, the authors conducted a retrospective cohort study which surveyed 80 firefighters exposed to burning polyvinyl chloride (PVC) as well as 15 nonexposed firefighter subjects. By means of an 81-item symptom checklist, exposed firefighters reported more frequent and severe symptoms at 5-6 weeks post incident. This was true for a total symptomatology score as well as 19 individual items. Some of the items with an elevated risk were consistent with exposure tomore » hydrogen chloride, the main pyrolysis product of polyvinyl chloride. Other items with an elevated risk appeared to be related to smoke inhalation while others seemed psychosocial in nature. Analyses conducted within the exposed firefighter group showed that fighting the fire the first day, being a truckman, and residence within 1 mile (1.6 km) of the firehouse were significant risk factors for high total symptom scores. These risk factors may have been associated with level or duration of exposure to the toxic substances produced during the fire.« less
76 FR 17327 - 100th Anniversary of the Triangle Shirtwaist Factory Fire
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-29
... responsibility to provide a safe environment for all American workers. NOW, THEREFORE, I, BARACK OBAMA, President... since the Triangle factory fire, we are still fighting to provide adequate working conditions for all... collective bargaining as a tool to give workers a seat at the tables of power. Working Americans are the...
US Research on Wildland Fires??…with a Focus on EPA’s Efforts
The United States spends more than $1 billion every year to fight wildfires. According to National Interagency Fire Center data, of the 10 years with the largest acreage burned, nine have occurred since 2000 (as of 2012). This period coincides with many of the warmest years on re...
DOT National Transportation Integrated Search
1995-05-01
A cabin water spray system (CWSS) has been suggested as a means of attenuating the severity of smoke and fire commonly associated with aircraft accidents. All aspects of passenger and cabin safety must be considered when evaluating a new safety syste...
ERIC Educational Resources Information Center
Stroud, Sara
2009-01-01
When Megan Meier hanged herself in 2006 after being the brunt of a MySpace prank, followed by the subsequent trial of the adult who participated in the 13-year-old girl's harassment, cyberbullying took its place in the eye of a media storm. All the ensuing attention has translated into increased concern among parents and a heightened awareness…
NASA Astrophysics Data System (ADS)
Thomopoulos, Stelios C. A.; Kyriazanos, Dimitris M.; Astyakopoulos, Alkiviadis; Dimitros, Kostantinos; Margonis, Christos; Thanos, Giorgos Konstantinos; Skroumpelou, Katerina
2016-05-01
AF3 (Advanced Forest Fire Fighting2) is a European FP7 research project that intends to improve the efficiency of current fire-fighting operations and the protection of human lives, the environment and property by developing innovative technologies to ensure the integration between existing and new systems. To reach this objective, the AF3 project focuses on innovative active and passive countermeasures, early detection and monitoring, integrated crisis management and advanced public information channels. OCULUS Fire is the innovative control and command system developed within AF3 as a monitoring, GIS and Knowledge Extraction System and Visualization Tool. OCULUS Fire includes (a) an interface for real-time updating and reconstructing of maps to enable rerouting based on estimated hazards and risks, (b) processing of GIS dynamic re-construction and mission re-routing, based on the fusion of airborne, satellite, ground and ancillary geolocation data, (c) visualization components for the C2 monitoring system, displaying and managing information arriving from a variety of sources and (d) mission and situational awareness module for OCULUS Fire ground monitoring system being part of an Integrated Crisis Management Information System for ground and ancillary sensors. OCULUS Fire will also process and visualise information from public information channels, social media and also mobile applications by helpful citizens and volunteers. Social networking, community building and crowdsourcing features will enable a higher reliability and less false alarm rates when using such data in the context of safety and security applications.
Theodore Ted Adams; Bret W. Butler; Sara Brown; Vita Wright; Anne Black
2017-01-01
Creating a safe workplace for wildland firefighters has long been at the centre of discussion for researchers and practitioners. The goal of wildland fire safety research has been to protect operational firefighters, yet its contributions often fall short of potential because much is getting lost in the translation of peer-reviewed results to potential and intended...
NASA Astrophysics Data System (ADS)
Barboni, T.; Santoni, P.-A.
2013-11-01
Prescribed burning represents a serious threat to the personnel fighting fires because of smoke inhalation. This study aims to increase the knowledge about foresters exposure to the prescribed burning smoke by focusing on exposure to volatile organic compounds (VOCs). We initially assessed the methodology for smoke sampling. Then, we identified potentially dangerous molecules among the VOCs identified at 4 prescribed burning sites located around Corsica. The values measured were very high, exceeding the exposure limits, particularly for benzene, phenol, and furfural, whose concentrations were above short-term exposure limit (STEL) values. In conclusion, obvious but necessary recommendations were made for the protection of the personnel involved in fighting fires on a professional basis.
2009-12-11
Abrams tanks and M2A3 Bradley fighting vehicles. The cities and villages had many obstacles such as narrow congested roads with single and multiple story...M1A2 tanks and M2A3 Bradley Fighting Vehicles were ―worth their weight in gold-when they rolled, the bad guys took notice and when they fired, the
A Multi-Agent System Architecture for Sensor Networks
Fuentes-Fernández, Rubén; Guijarro, María; Pajares, Gonzalo
2009-01-01
The design of the control systems for sensor networks presents important challenges. Besides the traditional problems about how to process the sensor data to obtain the target information, engineers need to consider additional aspects such as the heterogeneity and high number of sensors, and the flexibility of these networks regarding topologies and the sensors in them. Although there are partial approaches for resolving these issues, their integration relies on ad hoc solutions requiring important development efforts. In order to provide an effective approach for this integration, this paper proposes an architecture based on the multi-agent system paradigm with a clear separation of concerns. The architecture considers sensors as devices used by an upper layer of manager agents. These agents are able to communicate and negotiate services to achieve the required functionality. Activities are organized according to roles related with the different aspects to integrate, mainly sensor management, data processing, communication and adaptation to changes in the available devices and their capabilities. This organization largely isolates and decouples the data management from the changing network, while encouraging reuse of solutions. The use of the architecture is facilitated by a specific modelling language developed through metamodelling. A case study concerning a generic distributed system for fire fighting illustrates the approach and the comparison with related work. PMID:22303172
A multi-agent system architecture for sensor networks.
Fuentes-Fernández, Rubén; Guijarro, María; Pajares, Gonzalo
2009-01-01
The design of the control systems for sensor networks presents important challenges. Besides the traditional problems about how to process the sensor data to obtain the target information, engineers need to consider additional aspects such as the heterogeneity and high number of sensors, and the flexibility of these networks regarding topologies and the sensors in them. Although there are partial approaches for resolving these issues, their integration relies on ad hoc solutions requiring important development efforts. In order to provide an effective approach for this integration, this paper proposes an architecture based on the multi-agent system paradigm with a clear separation of concerns. The architecture considers sensors as devices used by an upper layer of manager agents. These agents are able to communicate and negotiate services to achieve the required functionality. Activities are organized according to roles related with the different aspects to integrate, mainly sensor management, data processing, communication and adaptation to changes in the available devices and their capabilities. This organization largely isolates and decouples the data management from the changing network, while encouraging reuse of solutions. The use of the architecture is facilitated by a specific modelling language developed through metamodelling. A case study concerning a generic distributed system for fire fighting illustrates the approach and the comparison with related work.
Forest Fires in Russia and Northern China
NASA Technical Reports Server (NTRS)
2002-01-01
Smoke plumes from forest fires scattered along the border between the Russian Far East and northern China are clearly visible in this true-color image from the Sea-viewing Wide-Field-of-view Sensor (SeaWiFS) on June 16, 2000. Fires in Siberia occur every summer, and severe outbreaks occur every ten years or so, with the most recent in 1998. The fires are ignited by lightning, and are so remote that it is impossible to fight them effectively. Provided by the SeaWiFS Project, NASA/Goddard Space Flight Center, and ORBIMAGE
NASA Technical Reports Server (NTRS)
Bickler, Donald B.; Sword, Lee F.; Lindemann, Randel A.
1994-01-01
Tires used where elastomeric and pneumatic tires would not function. Metal tires withstand extreme temperatures. Used on Earth for vehicles and robots that fight fires or clean up dangerous chemicals.
STS-40 MS Seddon pauses during fire fighting training at JSC's Fire Pit
1990-08-22
S90-46497 (18 Aug 1990) --- Astronaut Rhea Seddon, STS-40 mission specialist, takes a break from firefighting training at the Johnson Space Center (JSC). In less than a year Dr. Seddon will be joined by four NASA astronauts and two payload specialists for the Spacelab Life Sciences (SLS-1) mission aboard Columbia.
Adjuncts Fight Back over Academic Freedom
ERIC Educational Resources Information Center
Wilson, Robin
2008-01-01
Steven Bitterman was fired by his school after he offended his students for telling them that they could easily appreciate the biblical story of Adam and Eve if they considered it a myth. Several adjunct and full-time professors who work off the tenure track have been fired after saying something, as Mr. Bitterman did, that offended students or…
Fire monitoring from space: from research to operation
NASA Astrophysics Data System (ADS)
Pergola, Nicola; Filizzola, Carolina; Corrado, Rosita; Coviello, Irina; lacava, Teodosio; Marchese, Francesco; Mazzeo, Giuseppe; Paciello, Rossana; Tramutoli, Valerio
2013-04-01
Each summer fires rage through European forests, burning hundreds of thousands of hectares per year, as a result of the many (up to 60000) forest fires that usually occur annually in Europe. Fires can threaten public health and safety, destroy property and cause economic damages. Despite of their medium extension (the average burnt area is less than 6 ha), much smaller if compared with other regions like the USA and Canada, the number of simultaneous active fires in Europe can be very high, fomented by weather conditions that, especially in summer times and for countries of South Europe, are particularly favourable to a rapid and dramatic development of flames. Fires still are not only a social problem, but also an environmental emergency, producing a continuous impoverishment of forests and possibly indirectly triggering other natural hazards (e.g. making slopes, without the trees action, more prone to landslides). Additionally, there is a general concern about the loss of biodiversity and the contribution to land degradation that fires may cause. Earth Observation satellite systems have been largely tested for fire detection and monitoring from space. Their spectral capability, synoptic view and revisit times can offer an added value in the operational use not only in real time, during fires fighting activities, but also in near-real or delay time during the phases of risk management and mitigation. However, the practice of an actual operational use of satellite products by end-users is still not usual at European level. This work is based on the experience carried out jointly by CNR-IMAA and the National Civil Protection Department (DPC), in the framework of a five-year agreement in which the operational use of an Earth observation satellite system for fires spotting and monitoring is tested. Satellite-based products, developed not only for detecting fires but also for continuously monitoring their evolution in time domain, have been provided to Civil Protection Department for the whole summer campaign on forest fires fighting, supporting their activities in routinely managing and monitoring forest fires risk. The experimented satellite system has demonstrated to provide valuable information that can be used by civil protection staff also in support to organization and allocation of fire fighting resources on ground, especially when, during the high risk periods, there are or are expected a large number of contemporary events. Training activities, devoted to make DPC staff fully able to self operate the provided satellite-based tool, were also carried out during this collaborative experience, which represents a best practice of a useful integration of satellite added value products within the operational framework of an expert user.
14 CFR 29.1197 - Fire extinguishing agents.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire extinguishing agents. 29.1197 Section... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Powerplant Fire Protection § 29.1197 Fire extinguishing agents. (a) Fire extinguishing agents must— (1) Be capable of extinguishing flames emanating from...
A Grey Area: Congressional Oversight of the Middle Ground Between Title 10 and Title 50
2012-06-01
for 1981, Title V. 43 Eric Rosenbach and Aki J. Peritz, Trials by Fire , Counterterrorism and the Law (Cambridge: Belfer Center for Science and...Potomac Books, 2005), 59. The authors use different terms to describe the same phenomena, Johnson uses police patrolling and fire fighting instead. 56...Trials by Fire , Counterterrorism and the Law (Cambridge: Belfer Center for Science and International Affairs, 2010), 8. 44 Kibbe, “The Rise of the
2007-10-24
Programs) 1 . FCS MULE .wmv format 2. FCS NLOS Crate Of Fire .wmv format 3. FCS Robotic Convoy .wmv format 4. FCS...included in these sessions will be two “back by popular demand” highlights from previous conferences: 1 ) an update on combat operations in iraq from...15 am - 11:30 am general session general sessiOn - sessiOn 1 : “today’s challenges: fighting, sustaining, modernizing and transforming
Chapter 17: Forecasting wildfire suppression expenditures for the United States Forest Service
Karen L. Abt; Jeffrey P. Prestemon; Krista Gebert
2008-01-01
The wildland fire management organization of the United States Forest Service (USFS) operates under policy and budget legacies that began nearly 100 years ago and a forest fuel situation that is all too current. The confluence of these three factors contributes to increased burning and fire fighting costs for the agency, and increased concern from both the U.S....
[Insurance system. Prevention from viewpoint of the insurer].
Brechtbühl, P
1978-12-01
The purpose of an insurance must not be restricted to the payment of claims to those insured persons who suffered a loss, for loss prevention is much preferable to claim settlement. A whole range of different institutions and measures has been established by the Swiss insurers, in which many insurance branches participate. The loss preventing activities can be listed as follows:--Activities of the fire insurers to prevent and fight fires. This is the prevailing duty of the Consulting Agency for Fire Prevention (BfB) as well as the Fire Prevention Service for Industry and Trade (BVD).--Activities of the accident insurers to prevent accidents. The fight against accidents, mostly traffic accidents, in sports and at home is the foremost task of the Swiss Council for the Prevention of Accidents (BfU), an institution created by the Conference of Accident Insurance Managers (UDK) and the Swiss National Accident Insurance Fund (SUVA).--The Health Service in life insurance, after all the periodical medical examinations and consultations granted by many insurers to their insured persons, as well as the pamphlets aiming at health education published by several Companies and finally institutions and measures to promote fitness, e.g. VITA-Parcours.
NASA Astrophysics Data System (ADS)
Wuttke, M. W.; Kessels, W.; Wessling, S.; Han, J.
2007-05-01
Spontaneous combustion is a world wide problem for technical operations in mining, waste disposal and power plant facilities. The principle driving the combustion is every where the same independent of the different reactive materials: Fresh air with the common oxygen content is getting in contact with the reactive material by human operations. The following reaction process produces heat at a usually low but constant rate. The reactive material in operating or abandoned coal mines, heaps of coal, waste or reactive minerals is most times strongly broken or fractured, such that the atmospheric oxygen can deeply penetrate into the porous or fractured media. Because the strongly broken or fractured medium with air filled pores and fractures is often combined with a low thermal conductivity of the bulk material the produced heat accumulates and the temperature increases with time. If the reactivity strongly increases with temperature, the temperature rise accelerates up to the "combustion temperature". Once the temperature is high enough the combustion process is determined by the oxygen transport to the combustion center rather than the chemical reactivity. Spontaneous combustion is thus a self- amplifying process where an initial small variation in the parameters and the starting conditions can create exploding combustion hot spots in an apparently homogenous material. The phenomenon will be discussed by various examples in the context of the German - Sino coal fire project. A temperature monitoring in hot fracture systems documents the strong influence of the weather conditions on the combustion process. Numerical calculations show the sensitivity of the combustion to the model geometries, the boundary conditions and mainly the permeability. The most used fire fighting operations like covering and water injection are discussed. A new method of using saltwater for fire fighting is presented and discussed. References: Kessels, W., Wessling, S., Li, X., and Wuttke, M. W. Numerical element distinction for reactive transport modeling regarding reaction rate. In Proceedings of MODFLOW and MORE 2006: Managing Groundwater Systems, May 21 - 24, 2006, Golden, CO USA (2006). Kessels, W., Wuttke, M. W., Wessling, S., and Li, X. Coal fires between self ignition and fire fighting: Numerical modeling and basic geophysical measurements. In ERSEC Ecological Book Series - 4 on Coal Fire Research (2007). Wessling, S., Litschke, T., Wiegand, J., Schlömer, S., and Kessels, W. Simulating dynamic subsurface coal fires and its applications. In ERSEC Ecological Book Series - 4 on Coal Fire Reserach (2007). Wessling, S., Kessels, W., Schmidt, M., and Krause, U. Investigating dynamic underground coal fires by means of numerical simulation. Geophys. J. Int. (submitted).
A New Application to Facilitate Post-Fire Recovery and Rehabilitation in Savanna Ecosystems
NASA Technical Reports Server (NTRS)
Carroll, Mark L.; Schnase, John L.; Weber, Keith T.; Brown, Molly E.; Gill, Roger L.; Haskett, George W.; Gardner, Tess A.
2013-01-01
The U.S. government spends an estimated $3billion per year to fight forest fires in the United States. Post-fire rehabilitation activities represent a small but essential portion of that total. The Rehabilitation Capability Convergence for Ecosystem Recovery (RECOVER) system is currently under development for Savanna ecosystems in the western U.S. The prototype of this system has been built and will have realworld testing during the summer 2013 fire season. When fully deployed, the RECOVER system will provide the emergency rehabilitation teams with critical and timely information for management decisions regarding stabilization and rehabilitation strategies.
Dunham, J.B.; Young, M.; Gresswell, Robert E.; Rieman, B.
2003-01-01
Our limited understanding of the short and long-term effects of fire on fish contributes to considerable uncertainty in assessments of the risks and benefits of fire management alternatives. A primary concern among the many potential effects of fire is the effects of fire and fire management on persistence of native fish populations. Limited evidence suggests vulnerability of fish to fire is contingent upon the quality of affected habitats, the amount and distribution of habitat (habitat fragmentation), and habitat specificity of the species in question. Species with narrow habitat requirements in highly degraded and fragmented systems are likely to be most vulnerable to fire and fire-related disturbance. In addition to effects of fire on native fish, there are growing concerns about the effects of fire on nonnative fish invasions. The role of fire in facilitating invasions by nonnative fishes is unknown, but experience with other species suggests some forms of disturbance associated with fire may facilitate invasion. Management efforts to promote persistence of fishes in fire-prone landscapes can take the form of four basic alternatives: (1) pre-fire management; (2) post-fire management; (3) managing fire itself (e.g. fire fighting); and (4) monitoring and adaptive management. Among these alternatives, pre-fire management is likely to be most effective. Effective pre-fire management activities will address factors that may render fish populations more vulnerable to the effects of fire (e.g. habitat degradation, fragmentation, and nonnative species). Post-fire management is also potentially important, but suffers from being a reactive approach that may not address threats in time to avert them. Managing fire itself can be important in some contexts, but negative consequences for fish populations are possible (e.g. toxicity of fire fighting chemicals to fish). Monitoring and adaptive management can provide important new information for evaluating alternatives, but proper implementation is often hampered by inadequate study designs and inconsistent financial and institutional support. The challenge for providing better management guidelines will be to add solid empirical data and models to assess the relevance of emerging concepts and theories, and provide a sense of where and when fires pose significant risks and/or benefits to fishes.
Cutting Off the Head of the Snake: Foreign Imposed Regime Change
2018-06-15
looked overwhelmingly female and/or elderly.”8 The population and common soldier became prey to a constant stream of bombing on a scale never previously...into enemy hands, and murdered their civilian compatriots in places such as Saipan and Okinawa. They watched helplessly as fire bombs destroyed...fatalities from bombing resulting in a loss of the will to fight, but did not suffer large scale losses.6 Rather, they decided to stop fighting in a
Semantic Agent-Based Service Middleware and Simulation for Smart Cities
Liu, Ming; Xu, Yang; Hu, Haixiao; Mohammed, Abdul-Wahid
2016-01-01
With the development of Machine-to-Machine (M2M) technology, a variety of embedded and mobile devices is integrated to interact via the platform of the Internet of Things, especially in the domain of smart cities. One of the primary challenges is that selecting the appropriate services or service combination for upper layer applications is hard, which is due to the absence of a unified semantical service description pattern, as well as the service selection mechanism. In this paper, we define a semantic service representation model from four key properties: Capability (C), Deployment (D), Resource (R) and IOData (IO). Based on this model, an agent-based middleware is built to support semantic service enablement. In this middleware, we present an efficient semantic service discovery and matching approach for a service combination process, which calculates the semantic similarity between services, and a heuristic algorithm to search the service candidates for a specific service request. Based on this design, we propose a simulation of virtual urban fire fighting, and the experimental results manifest the feasibility and efficiency of our design. PMID:28009818
Semantic Agent-Based Service Middleware and Simulation for Smart Cities.
Liu, Ming; Xu, Yang; Hu, Haixiao; Mohammed, Abdul-Wahid
2016-12-21
With the development of Machine-to-Machine (M2M) technology, a variety of embedded and mobile devices is integrated to interact via the platform of the Internet of Things, especially in the domain of smart cities. One of the primary challenges is that selecting the appropriate services or service combination for upper layer applications is hard, which is due to the absence of a unified semantical service description pattern, as well as the service selection mechanism. In this paper, we define a semantic service representation model from four key properties: Capability (C), Deployment (D), Resource (R) and IOData (IO). Based on this model, an agent-based middleware is built to support semantic service enablement. In this middleware, we present an efficient semantic service discovery and matching approach for a service combination process, which calculates the semantic similarity between services, and a heuristic algorithm to search the service candidates for a specific service request. Based on this design, we propose a simulation of virtual urban fire fighting, and the experimental results manifest the feasibility and efficiency of our design.
Fire behavior and risk analysis in spacecraft
NASA Technical Reports Server (NTRS)
Friedman, Robert; Sacksteder, Kurt R.
1988-01-01
Practical risk management for present and future spacecraft, including space stations, involves the optimization of residual risks balanced by the spacecraft operational, technological, and economic limitations. Spacecraft fire safety is approached through three strategies, in order of risk: (1) control of fire-causing elements, through exclusion of flammable materials for example; (2) response to incipient fires through detection and alarm; and (3) recovery of normal conditions through extinguishment and cleanup. Present understanding of combustion in low gravity is that, compared to normal gravity behavior, fire hazards may be reduced by the absence of buoyant gas flows yet at the same time increased by ventilation flows and hot particle expulsion. This paper discusses the application of low-gravity combustion knowledge and appropriate aircraft analogies to fire detection, fire fighting, and fire-safety decisions for eventual fire-risk management and optimization in spacecraft.
An approach to the real time risk evaluation system of boreal forest fire
NASA Astrophysics Data System (ADS)
Nakau, K.; Fukuda, M.; Kimura, K.; Hayasaka, H.; Tani, H.; Kushida, K.
2005-12-01
Huge boreal forest fire may cause massive impacts not only on global warming gas emission but also local communities. Thus, it is important to control forest fire. We collected data about boreal forest fire as satellite imagery and fire observation simultaneously in Alaska and east Siberia in summer fire seasons for these three years. Fire observation data was collected from aircraft flying between Japan and Europe. Fire detection results were compared with observed data to evaluate the accuracy and earliness of automatic detection. NOAA and MODIS satellite images covering Alaska and East Siberia are collected. We are also developing fire expansion simulation model to forecast the possible fire expansion area. On the basis of fire expansion forecast, risk analysis of possible fire expansion for decision aid of fire-fighting activities will be analyzed. To identify the risk of boreal forest fire and public concern about forest fire, we collected local news paper in Fairbanks, AK and discuss the statistics of articles related to forest fire on the newspaper.
1977-11-15
for the theater airbase, pavement studies, environmental pollution abatement and control, air mobility concepts, energy conservation, fire fighting equipment, air base support, and warm fog dispersal. (Author)
Comparison of Carbon Dioxide and Helium as Fire Extinguishing Agents for Spacecraft
NASA Technical Reports Server (NTRS)
Gokoglu, Suleyman; Son, Youngjin; Ronney, Paul D.
2004-01-01
The effects of radiation heat transfer in microgravity compared to convection heat transfer in earth gravity for opposed-flow (downward) over thermally-thick fuel using low density foam fuel were investigated. Microgravity experiments on flame spread over thermally-thick fuels were conducted using foam fuels to obtain low density and thermal conductivity, and thus large flame spread rate compared to dense fuels such as PMMA. And thereby valid microgravity results were obtained even in 2.2 second drop-tower experiments not to mention for the longer duration tests in Zero Gravity Facility. Contrast to the conventional understanding, it was found that steady flame spread can occur over thick fuels in quiescent microgravity environments, especially when radiatively-active diluent gases such as CO2 were employed. This is proposed to result from radiative heat transfer from the flame to the fuel surface, which could lead to steady spread even when the amount of the heat transfer via conduction from the flame to the fuel bed is negligible. Radiative effects are more significant at microgravity conditions because the flame is thicker and thus the volume of radiating combustion products is larger as well. These results suggested that helium may be a better inert or extinguishment agent on both a mass and a mole bases at microgravity even though CO2 is much better on a mole bases at earth gravity, and these are relevant to studies of fire safety in manned spacecraft, particularly the International Space Station that uses CO2 fire extinguishers. CO2 may not be as effective as an extinguishing agent at microgravity as it is at earth gravity in some conditions because of the differences in spread mechanisms between the two cases. In particular, the difference between conduction-dominated heat transport to the fuel bed at earth gravity and radiation-dominated heat transport at microgravity indicates that radiatively-inert diluent such as helium could be preferable in microgravity applications. Helium may be a superior fire suppression agent at microgravity on several bases. First, helium is more effective than CO2 on a mole basis (thus pressure times storage volume basis) at microgravity, meaning that the size and weight of storage bottles would be smaller for the same fire-fighting capability. Second; helium is much more effective on a mass basis (by about 11 times) at microgravity. Third; helium has no physiological activity, unlike CO2 that affects human respiration. Fourth, as compared to N2 or CO2, is not very soluble in water and thus has fewer tendencies to cause bloodstream bubble formation following rapid spacecraft cabin depressurization.
Comparison of Carbon Dioxide and Helium as Fire Extinguishing Agents for Spacecraft
NASA Technical Reports Server (NTRS)
Gokoglu, Suleyman; Son, Youngjin; Ronney, Paul D.
2004-01-01
The effects of radiation heat transfer in microgravity compared to convection heat transfer in earth gravity for opposed-flow (downward) over thermally-thick fuel using low density foam fuel were investigated. Microgravity experiments on flame spread over thermally-thick fuels were conducted using foam fuels to obtain low density and thermal conductivity, and thus large flame spread rate compared to dense fuels such as PMMA. And thereby valid microgravity results were obtained even in 2.2 second drop-tower experiments not to mention for the longer duration tests in Zero Gravity Facility. Contrast to the conventional understanding, it was found that steady flame spread can occur over thick fuels in quiescent microgravity environments, especially when radiatively-active diluent gases such as CO2 were employed. This is proposed to result from radiative heat transfer from the flame to the fuel surface, which could lead to steady spread even when the amount of the heat transfer via conduction from the flame to the fuel bed is negligible. Radiative effects are more significant at microgravity conditions because the flame is thicker and thus the volume of radiating combustion products is larger as well. These results suggested that helium may be a better inert or extinguishment agent on both a mass and a mole bases at microgravity even though CO2 is much better on a mole bases at earth gravity, and these are relevant to studies of fire safety in manned spacecraft, particularly the International Space Station that uses CO2 fire extinguishers. CO2 may not be as effective as an extinguishing agent at g as it is at earth gravity in some conditions because of the differences in spread mechanisms between the two cases. In particular, the difference between conduction-dominated heat transport to the fuel bed at earth gravity and radiation-dominated heat transport at g indicates that radiatively-inert diluent such as helium could be preferable in g applications. Helium may be a superior fire suppression agent at g on several bases. First, helium is more effective than CO2 on a mole basis (thus pressure times storage volume basis) at g, meaning that the size and weight of storage bottles would be smaller for the same fire-fighting capability. Second; helium is much more effective on a mass basis (by about 11 times) at g. Third; helium has no physiological activity, unlike CO2 that affects human respiration. Fourth, as compared to N2 or CO2, is not very soluble in water and thus has fewer tendencies to cause bloodstream bubble formation following rapid spacecraft cabin depressurization.
Forest Service Turns to NREL for Help Fighting Fires More Sustainably |
reduce energy and water use as well as waste generation at fire camps and supporting operations , burn less fuel, generate less waste, and recycle more. While NREL is often called upon to identify how fundamentally it would be nice to see some savings realized on the energy, water, or waste side, and to add some
Unmanned Ground Vehicles for Integrated Force Protection
2004-04-01
employed. 2 Force Protection 18 MAR 02 Security Posts Squad Laptop Fire Tm Ldr Wearable Computers OP/LP Def Fight Psn SRT Sensors USA, USMC, Allied...visual systems. Attaching sensors and response devices on a monorail proved to be much more technically challenging than expected. Film producers and...facilitate experimentation with weapon aiming and firing techniques from the MRHA. grated Marsupial Delivery System was developed to transport smaller
Code of Federal Regulations, 2011 CFR
2011-07-01
....34(m) and 570.54(c): (i) Straightening, marking, or tallying lumber on the dry chain or the dry drop sorter. (ii) Pulling lumber from the dry chain, except minors under 16 years of age may not pull lumber from the dry chain as such youth are prohibited from operating or tending power-driven machinery by...
Code of Federal Regulations, 2013 CFR
2013-07-01
....34(m) and 570.54(c): (i) Straightening, marking, or tallying lumber on the dry chain or the dry drop sorter. (ii) Pulling lumber from the dry chain, except minors under 16 years of age may not pull lumber from the dry chain as such youth are prohibited from operating or tending power-driven machinery by...
Code of Federal Regulations, 2012 CFR
2012-07-01
....34(m) and 570.54(c): (i) Straightening, marking, or tallying lumber on the dry chain or the dry drop sorter. (ii) Pulling lumber from the dry chain, except minors under 16 years of age may not pull lumber from the dry chain as such youth are prohibited from operating or tending power-driven machinery by...
Code of Federal Regulations, 2014 CFR
2014-07-01
....34(m) and 570.54(c): (i) Straightening, marking, or tallying lumber on the dry chain or the dry drop sorter. (ii) Pulling lumber from the dry chain, except minors under 16 years of age may not pull lumber from the dry chain as such youth are prohibited from operating or tending power-driven machinery by...
Heat shields for aircraft - A new concept to save lives in crash fires.
NASA Technical Reports Server (NTRS)
Neel, C. B.; Parker, J. A.; Fish, R. H.; Henshaw, J.; Newland, J. H.; Tempesta, F. L.
1971-01-01
A passenger compartment surrounded by a fire-retardant shell, to protect the occupants long enough for the fire to burn out or for fire-fighting equipment to reach the aircraft and extinguish it, is proposed as a new concept for saving lives in crash fires. This concept is made possible by the recent development of two new fire-retardant materials: a very lightweight foam plastic, called polyisocyanurate foam, and an intumescent paint. Exposed to heat, the intumescent paint expands to many times its original thickness and insulates the surface underneath it. Demonstration tests are illustrated, described and discussed. However, some problems, such as preventing fuselage rupture and protecting windows, must be solved before such a system can be used.
Numerical Modelling by FLAC on Coal Fires in North China
NASA Astrophysics Data System (ADS)
Gusat, D.; Drebenstedt, C.
2009-04-01
Coal fires occur in many countries all over the world (e.g. Australia, China, India, Indonesia, USA and Russia) in underground and on surface. In China the most coal fires occur especially in the North. Economical and environmental damages are the negative effects of the coal fires: coal fires induce open fractures and fissures within the seam and neighbouring rocks. So that these are the predominant pathways for oxygen flow and exhaust gases from a coal fire. All over northern China there are a large number of coal fires, which cause and estimated yearly coal loss of between 100 and 200 million tons ([1], [2], [3]). Spontaneous combustion is a very complicated process and is influenced by number of factors. The process is an exothermic reaction in which the heat generated is dissipated by conduction to the surrounding environment, by radiation, by convection to the ventilation flow, and in some cases by evaporation of moisture from the coal [4]. The coal fires are very serious in China, and the dangerous extent of spontaneous combustion is bad which occupies about 72.9% in mining coal seams. During coal mining in China, the coal fires of spontaneous combustion are quite severity. The dangerous of coal spontaneous combustion has been in 56% of state major coalmines [5]. The 2D and 3D-simulation models describing coal fire damages are strong tools to predict fractures and fissures, to estimate the risk of coal fire propagation into neighbouring seams, to test and evaluate coal fire fighting and prevention methods. The numerical simulations of the rock mechanical model were made with the software for geomechanical and geotechnical calculations, the programs FLAC and FLAC3D [6]. To fight again the coal fires, exist several fire fighting techniques. Water, slurries or liquefied nitrogen can be injected to cool down the coal or cut of air supply with the backfill and thereby extinct the fire. Air supply also can be cut of by covering the coal by soil or sealing of the coal mine with the backfill. A smaller fires can also be handled by taking out burning coal by bulldozing techniques described above are applicable to small fires, but they do not work well in extinction of large coal fires. References [1] http://www.coalfire.caf.dlr.de [2] Schalke, H.J.W.G.; Rosema, A.; Van Genderen, J.L. (1993): Environmental monitoring of coal fires in North China. Project Identification Mission Report. Report Remote Sensing Programme Board, Derft, the Netherlands. [3] Zhang, X.; Kroonenberg, S. B.; De Boer, C. B. (2004): Dating of coal fires in Xinjiang, north-west China. Terra Nova. Band 16, No 2, S. 68-74. DOI: 10.1111/j.1365-3121.2004.00532.x [4] Deng Jun, Hou Shuang, Li Huirong, e.t.c (2006): Oxidation Mechanism at Initial Stage of a Simulated Coal Molecule with -CH2O-[J]. Journal of Changchun University of Science and Technology, 29(2), P. 84-87. [5] Deng, Jun (2008): Presentation. Chinese Researches and Practical Experiences on Controlling Underground Coal Fires. The 2nd Australia-China Symposium on Science, Technology and Education. 15-18 October 2008, Courtyard Marriott, Surfers Paradise Beach, Gold Coast, Queensland, Australia. [6] Itasca (2003): FLAC, Fast Lagrangian Analysis of Continua. Itasca Consultants Group, Inc., Minneapolis.
Air Force Civil Engineering Center Fiscal Year 1978 Air Force Technical Objectives Document.
1976-12-15
for the theater airbase, pavement studies, environmental pollution abatement and control, air mobility concepts, energy conservation, fire fighting equipment, air base support, and warm fog dispersal. (Author)
A 21st Century Navy Vision: Motivating Sailors to Achieve Maximum Warfighting Readiness
2001-06-01
answers, continues to focus on external matters. Observers suggest that perhaps it is time for the Navy to take a hard look inward, and develop an...a reality emerges that it is hard to think strategically when fighting daily people wars in the trenches. 40000 45000 50000 55000 60000 Beginning of...be unfairly under fire or to tell the unpopular truth about declining readiness, well, better to live and fight another day, they rationalize. Time
Power Projection: The Current and Future Relevance of the M1A1Tank to Marine Corps Capabilities
2002-01-01
Kenneth W. Estes, Marines under Armor : The Marine Corps and the Armored Fighting Vehicle, 1916-2000 (Annapolis, MD: Naval institute Press, 2000), 183...is the M2 heavy barrel machine gun that has been in the U.S. inventory for decades. It can be fired from under armor and has a range of 1800 meters...Accessed 9 January 2002. Estes, Kenneth W. Marines under Armor : The Marine Corps and the Armored Fighting Vehicle, 1916-2000. Annapolis, MD
Handheld Delivery System for Modified Boron-Type Fire Extinguishment Agent
1993-11-01
was to develop and test a handheld portable delivery system for use with the modified boron-type fire extinguishing agent for metal fires . B...BACKGROUND A need exists for an extinguishing agent and accompanying delivery system that are effective against complex geometry metal fires . A modified...agent and its delivery system have proven effective against complex geometry metal fires containing up to 200 pounds of magnesium metal. Further
Forest fire spatial pattern analysis in Galicia (NW Spain).
Fuentes-Santos, I; Marey-Pérez, M F; González-Manteiga, W
2013-10-15
Knowledge of fire behaviour is of key importance in forest management. In the present study, we analysed the spatial structure of forest fire with spatial point pattern analysis and inference techniques recently developed in the Spatstat package of R. Wildfires have been the primary threat to Galician forests in recent years. The district of Fonsagrada-Ancares is one of the most seriously affected by fire in the region and, therefore, the central focus of the study. Our main goal was to determine the spatial distribution of ignition points to model and predict fire occurrence. These data are of great value in establishing enhanced fire prevention and fire fighting plans. We found that the spatial distribution of wildfires is not random and that fire occurrence may depend on ownership conflicts. We also found positive interaction between small and large fires and spatial independence between wildfires in consecutive years. Copyright © 2013 Elsevier Ltd. All rights reserved.
Elimination of spades in wheeled military vehicles using MR-fluid dampers
NASA Astrophysics Data System (ADS)
Hosseinloo, Ashkan H.; Vahdati, Nader; Yap, Fook Fah
2011-03-01
Tracked military vehicles were the choice of fighting vehicles due to their heavy fire power, better armor package distribution, better traction, and ability to fire on the move without spades. Many armies are converting to all wheeled vehicles, but one of the drawbacks is the inability to fire on the move without spades. A 2D heave pitch vehicle model for HMMWV has been developed. Simulation results indicate that by the use of MR-fluid dampers with the skyhook controls, it is possible to remove the spades, control chassis vibration, and prevent vehicle lift off during mortar firing, without bursting the tires.
Guide Specification For Water/Foam Aircraft Rescue and Firefighting Vehicles
DOT National Transportation Integrated Search
2002-02-18
This advisory circular (AC) contains performance standards, specifications, and : recommendations for the design, construction, and testing of a family of : aircraft rescue and fire fighting (ARFF) vehicles. The guide specifications : covers two clas...
A software framework for assessing the resilience of drinking ...
Journal article This paper introduces a new software tool called the Water Network Tool for Resilience (WNTR) that water utilities can use to assess their resilience to disasters. A case study of an earthquake is included that results in damage to pipes and tanks, fires, and power outages. The utility uses several response strategies including fixing damaged pipes and tanks, restoring power, fighting fires, and implementing conservation.
Fire Fighting Task Force (FIRE)
1989-04-01
and fdenify by block number) ~’This study is part of ~a contining effort to develop soldier data and performance algorithms (pergorithus) needed to...similar to combat, results will be useful in developing algorithms and data for use in US Army Concepts Analysis Agency (CAA) combat models. THE...dimensions. The US Army Concepts Analysis Agency (CAA) is committed to adding the soldier variables and algorithms that are necessary to fully represent
Firefighting module development
NASA Technical Reports Server (NTRS)
Burns, R. A.
1981-01-01
The firefighting module is a lightweight, compact, self contained, helicopter-transportable unit for fighting harbor and other specialty fires as well as for use in emergency water pumping applications. Units were fabricated and tested. A production type unit is undergoing an inservice evaluation and demonstration program at the port of St Louis. The primary purpose is to promote enhanced harbor fire protection at inland and coastal ports. The module and its development are described.
Sue Miller; Patty Champ; Hannah Brenkert-Smith
2013-01-01
New home building in the wildland-urban interface (WUI) continues unabated, despite the high financial and human costs of fighting fires in these areas. The goal of this research is to understand, through surveys and expert assessments, the attitudes and perceptions of WUI homeowners as they relate to taking action to reduce wildfire risk on their property. It also...
A Feasibility Study on the Establishment of a Fire Fighting Academy for the State of New Mexico.
ERIC Educational Resources Information Center
Sanchez, Alex A.
The report on the desirability and feasibility of establishing the New Mexico State Fire Academy and firemen training program is presented in three parts: (1) the result of a survey of firemen training, (2) a proposal for a total system of firemen training, and (3) an analysis of the cost of implementing this program of training and education. The…
[The "Mining Rescue System and Mine Fires" Working Group. Tasks, results, future activities].
Coenders, A
1983-01-01
The president of the working party presents details of its principal tasks in the past and in the present time. These can be summed up in a study of the problems mentioned below and the subsequent elaboration of recommendations for the benefit of the governments, guidelines, information reports and research proposals. The principal problems that were or are still under study are: --prevention of fires: shaft equipment, hydraulic fluids, belt conveyors, . . .; --detection of mine fires and spontaneous combustion; --fighting of mine fires: shaft fires, construction of stoppings, openings and recovering of fire zones, . . .; --coordination and rescue equipment: escape and rescue breathing apparatus, flameproof clothing, rescue of trapped miners; --stabilization of ventilation in the event of fire, . . . The speaker stresses the importance of the information exchange and the atmosphere of fellowship and solidarity that prevails in the working party.
1994-04-01
RDC 91-6 May 1991 SYNOPSIS: In response to the need for an ef- fective fire-extinguishing agent for metal fires , we have developed an effective...react violently when used on metal fires . A 3-year research program produced a series of highly effective agents known as boralons--blends of an...ESL-TR-86-17, Ex. hand fire extinguishers where tinguishing Agent for Magnesium magnesium or other metal fires are Fires. expected. BENEFITS: The new
RISICO: A decision support system (DSS) for dynamic wildfire risk evaluation in Italy
NASA Astrophysics Data System (ADS)
D'Andrea, Mirko; Fiorucci, Paolo; Gaetani, Francesco; Negro, Dario
2010-05-01
The system RISICO provides Italian Civil Protection Department (DPC) with daily wildland fire risk forecast maps relevant to the whole national territory since 2003. RISICO support the activities relating to Italian national forest fires warning system and National fires fighting air fleet. The RISICO system has a complex software architecture based on a framework able to manage geospatial data as well as time dependent information (e.g, Numerical Weather Prediction, real time meteorological observations, and satellite data). Within the system semi-physical models, able to simulate in space and time the variability of the fuel moisture content, are implemented. This parameter represents the main variable related with the ignition of a fire. Based on this information and introducing information on topography and wind field the model provides the rate of spread and the linear intensity of a potential fire generated by accidental or deliberate ignition. The model takes into account the vegetation patterns, in terms of fuel load and flammability. It needs territorial and meteorological data. Territorial data used by the system are vegetation cover and topography. Meteorological data are mainly represented by Numerical Weather Prediction (Limited Area model). Meteorological data provided in real time by a meteorological network are also used by the model as well as satellite data (e.g., vegetation index, snow cover). The output information are provided on a web-gis based system according with the OGC-INSPIRE standard. In 2007 the system has been improved introducing some changes both in the model structure and its functionality. Spatial resolution is increased up to 100m in the implementation at regional level. The fine fuel moisture model has been changed, introducing the FFMC of the CFFDRS with some slightly differences. In addition, a different nominal rate of spread (no-wind on flat terrain) has been introduced for each different class of vegetation. The operational chain of the RISICO system is considerably changed. In the first release the system run daily making use of observations only to define the initial state of the dead fine fuel moisture content. The new version of the system is able to run each 3-h making use of observations at each time step. In order to validate the RISICO system, the information obtained from the analysis of really occurred fires has been compared with the information generated by RISICO system. In particular, a data set of more than 11000 wildland fires occurred in Italy between 01/01/2007 and 31/12/2008 has been considered in the validation procedure. The performance indexes selected in order to measure the system effectiveness are relevant to the capability of identifying the correct danger classes with reference to the extension and duration of the fire. In this connection, a comparison between the performance obtained by the new release of the RISICO system and the previous one has been carried out highlighting separately the improvement given by the higher resolution, the model structure and the operational chain. The system RISICO is able to integrate the main Fire Hazard Indexes present in the literature providing a suitable tool for testing the different indexes on the same platform in different environmental and climatic conditions. Risico represents an operational approach to forest fires management both during the prevention and fire fighting phases. The prevention phase represents the main goal for the DPC. Prevention starts with a daily bulletin issue. The bulletin is based on RISICO data, forecast, meteorological data and other observed data such as active fires. The bulletin is dispatched to all operative bodies employed both in fire fighting and civil protection activities. During the fire fighting activities Risico support decision maker to define the best strategies. The objective of the paper is to promote the use of Fire Hazard Forecast as operational tool in fire risk prevention and management and to provide know-how for standardisation of the fire hazard "mapping" or "alert" systems in Europe. This work was funded by the Italian Civil Protection.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Denise Baclawski
2010-03-08
The University of Nevada, Reno Fire Science Academy (FSA) applied for grant funding to develop and deliver programs for municipal, rural, and volunteer firefighters. The FSA specializes in preparing responders for a variety of emergency events, including flammable liquid fires resulting from accidents, intentional acts, or natural disasters. Live fire training on full scale burnable props is the hallmark of FSA training, allowing responders to practice critical skills in a realistic, yet safe environment. Unfortunately, flammable liquid live fire training is often not accessible to municipal, rural, or volunteer firefighters due to limited department training budgets, even though most departmentmore » personnel will be exposed to flammable liquid fire incidents during the course of their careers. In response to this training need, the FSA developed a course during the first year of the grant (Year One), Responding to Terrorist Incidents in Your Community: Flammable-Liquid Fire Fighting Techniques for Municipal and Rural Firefighters. During the three years of the grant, a total of 2,029 emergency responders received this training. In Year Three, two new courses, a train-the-trainer for Responding to Terrorist Incidents in Your Community and Management of Large-Scale Disasters for Public Officials were developed and pilot tested during the Real-World Disaster Management Conference held at the FSA in June of 2007. Two research projects were conducted during Years Two and Three. The first, conducted over a two year period, evaluated student surveys regarding the value of the flammable liquids training received. The second was a needs assessment conducted for rural Nevada. Both projects provided important feedback and a basis for curricula development and improvements.« less
NASA Technical Reports Server (NTRS)
1972-01-01
Device, jetcord, is metal-clad linear explosive of sufficient flexibility to allow forming into intricate shapes. Total effect is termed ''cutting'' with jetcord consistently ''cutting'' a target of greater thickness than can be penetrated. Applications include sheet metal working, pipe cutting and fire-fighting.
46 CFR Appendix B to Subpart C of... - Substance Technical Guidelines, Benzene
Code of Federal Regulations, 2012 CFR
2012-10-01
...) Extinguishing media: Carbon dioxide, dry chemical, or foam. (5) Special fire fighting procedures: Do not use a... ignited by open flames or sparks at locations remote from the site at which benzene is handled. (7...
46 CFR Appendix B to Subpart C to... - Substance Technical Guidelines, Benzene
Code of Federal Regulations, 2011 CFR
2011-10-01
...) Extinguishing media: Carbon dioxide, dry chemical, or foam. (5) Special fire fighting procedures: Do not use a... ignited by open flames or sparks at locations remote from the site at which benzene is handled. (7...
46 CFR Appendix B to Subpart C of... - Substance Technical Guidelines, Benzene
Code of Federal Regulations, 2014 CFR
2014-10-01
...) Extinguishing media: Carbon dioxide, dry chemical, or foam. (5) Special fire fighting procedures: Do not use a... ignited by open flames or sparks at locations remote from the site at which benzene is handled. (7...
Credit BG. Interior of Deluge Water Booster Station displaying highcapacity ...
Credit BG. Interior of Deluge Water Booster Station displaying high-capacity electrically driven water pumps for fire fighting service - Edwards Air Force Base, North Base, Deluge Water Booster Station, Northeast of A Street, Boron, Kern County, CA
Measuring Wildfires From Aircraft And Satellites
NASA Technical Reports Server (NTRS)
Brass, J. A.; Arvesen, J. C.; Ambrosia, V. G.; Riggan, P. J.; Meyers, J. S.
1991-01-01
Aircraft and satellite systems yield wide-area views, providing total coverage of affected areas. System developed for use aboard aircraft includes digital scanner that records data in 12 channels. Transmits data to ground station for immediate use in fighting fires. Enables researchers to estimate gaseous and particulate emissions from fires. Provides information on temperatures of flame fronts and soils, intensities and rate of spread of fires, characteristics of fuels and smoke plumes, energy-release rates, and concentrations and movements of trace gases. Data relates to heating and cooling of soils, loss of nutrients, and effects on atmospheric, terrestrial, and aquatic systems.
14 CFR 125.163 - Fire-extinguishing agents.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Fire-extinguishing agents. 125.163 Section... Requirements § 125.163 Fire-extinguishing agents. Only methyl bromide, carbon dioxide, or another agent that... some other person using satisfactory recharging equipment. If carbon dioxide is used, it must not be...
Mistry, Jayalaxshmi; Schmidt, Isabel Belloni; Eloy, Ludivine; Bilbao, Bibiana
2018-05-11
Wildfires continue to cause damage to property, livelihoods and environments around the world. Acknowledging that dealing with wildfires has to go beyond fire-fighting, governments in countries with fire-prone ecosystems have begun to recognize the multiple perspectives of landscape burning and the need to engage with local communities and their practices. In this perspective, we outline the experiences of Brazil and Venezuela, two countries where fire management has been highly contested, but where there have been recent advances in fire management approaches. Success of these new initiatives have been measured by the reduction in wildfire extent through prescribed burning, and the opening of a dialogue on fire management between government agencies and local communities. Yet, it is clear that further developments in community participation need to take place in order to avoid the appropriation of local knowledge systems by institutions, and to better reflect more equitable fire governance.
Autonomous UAV-based mapping of large-scale urban firefights
NASA Astrophysics Data System (ADS)
Snarski, Stephen; Scheibner, Karl; Shaw, Scott; Roberts, Randy; LaRow, Andy; Breitfeller, Eric; Lupo, Jasper; Nielson, Darron; Judge, Bill; Forren, Jim
2006-05-01
This paper describes experimental results from a live-fire data collect designed to demonstrate the ability of IR and acoustic sensing systems to detect and map high-volume gunfire events from tactical UAVs. The data collect supports an exploratory study of the FightSight concept in which an autonomous UAV-based sensor exploitation and decision support capability is being proposed to provide dynamic situational awareness for large-scale battalion-level firefights in cluttered urban environments. FightSight integrates IR imagery, acoustic data, and 3D scene context data with prior time information in a multi-level, multi-step probabilistic-based fusion process to reliably locate and map the array of urban firing events and firepower movements and trends associated with the evolving urban battlefield situation. Described here are sensor results from live-fire experiments involving simultaneous firing of multiple sub/super-sonic weapons (2-AK47, 2-M16, 1 Beretta, 1 Mortar, 1 rocket) with high optical and acoustic clutter at ranges up to 400m. Sensor-shooter-target configurations and clutter were designed to simulate UAV sensing conditions for a high-intensity firefight in an urban environment. Sensor systems evaluated were an IR bullet tracking system by Lawrence Livermore National Laboratory (LLNL) and an acoustic gunshot detection system by Planning Systems, Inc. (PSI). The results demonstrate convincingly the ability for the LLNL and PSI sensor systems to accurately detect, separate, and localize multiple shooters and the associated shot directions during a high-intensity firefight (77 rounds in 5 sec) in a high acoustic and optical clutter environment with very low false alarms. Preliminary fusion processing was also examined that demonstrated an ability to distinguish co-located shooters (shooter density), range to <0.5 m accuracy at 400m, and weapon type. The combined results of the high-intensity firefight data collect and a detailed systems study demonstrate the readiness of the FightSight concept for full system development and integration.
Optimization of the resources management in fighting wildfires.
Martin-Fernández, Susana; Martínez-Falero, Eugenio; Pérez-González, J Manuel
2002-09-01
Wildfires lead to important economic, social, and environmental losses, especially in areas of Mediterranean climate where they are of a high intensity and frequency. Over the past 30 years there has been a dramatic surge in the development and use of fire spread models. However, given the chaotic nature of environmental systems, it is very difficult to develop real-time fire-extinguishing models. This article proposes a method of optimizing the performance of wildfire fighting resources such that losses are kept to a minimum. The optimization procedure includes discrete simulation algorithms and Bayesian optimization methods for discrete and continuous problems (simulated annealing and Bayesian global optimization). Fast calculus algorithms are applied to provide optimization outcomes in short periods of time such that the predictions of the model and the real behavior of the fire, combat resources, and meteorological conditions are similar. In addition, adaptive algorithms take into account the chaotic behavior of wildfire so that the system can be updated with data corresponding to the real situation to obtain a new optimum solution. The application of this method to the Northwest Forest of Madrid (Spain) is also described. This application allowed us to check that it is a helpful tool in the decision-making process.
Optimization of the Resources Management in Fighting Wildfires
NASA Astrophysics Data System (ADS)
Martin-Fernández, Susana; Martínez-Falero, Eugenio; Pérez-González, J. Manuel
2002-09-01
Wildfires lead to important economic, social, and environmental losses, especially in areas of Mediterranean climate where they are of a high intensity and frequency. Over the past 30 years there has been a dramatic surge in the development and use of fire spread models. However, given the chaotic nature of environmental systems, it is very difficult to develop real-time fire-extinguishing models. This article proposes a method of optimizing the performance of wildfire fighting resources such that losses are kept to a minimum. The optimization procedure includes discrete simulation algorithms and Bayesian optimization methods for discrete and continuous problems (simulated annealing and Bayesian global optimization). Fast calculus algorithms are applied to provide optimization outcomes in short periods of time such that the predictions of the model and the real behavior of the fire, combat resources, and meteorological conditions are similar. In addition, adaptive algorithms take into account the chaotic behavior of wildfire so that the system can be updated with data corresponding to the real situation to obtain a new optimum solution. The application of this method to the Northwest Forest of Madrid (Spain) is also described. This application allowed us to check that it is a helpful tool in the decision-making process.
130. Photocopied July 1978. 'CAR NO. 8 PARKED AT QUINCY ...
130. Photocopied July 1978. 'CAR NO. 8 PARKED AT QUINCY NO. 2 SHAFT.' CAR NO. 8 CARRIED BUREAU OF MINES EMERGENCY TEAM TO QUINCY TO HELP FIGHT AN UNDERGROUND FIRE. JULY 1927. - Quincy Mining Company, Hancock, Houghton County, MI
49 CFR 175.9 - Special aircraft operations.
Code of Federal Regulations, 2014 CFR
2014-10-01
... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION HAZARDOUS MATERIALS REGULATIONS CARRIAGE BY AIRCRAFT General...) Exceptions. This subchapter does not apply to the following materials used for special aircraft operations... aircraft. (4) Hazardous materials are carried and used during dedicated air ambulance, fire fighting, or...
49 CFR 175.9 - Special aircraft operations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION HAZARDOUS MATERIALS REGULATIONS CARRIAGE BY AIRCRAFT General...) Exceptions. This subchapter does not apply to the following materials used for special aircraft operations... aircraft. (4) Hazardous materials are carried and used during dedicated air ambulance, fire fighting, or...
49 CFR 175.9 - Special aircraft operations.
Code of Federal Regulations, 2013 CFR
2013-10-01
... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION HAZARDOUS MATERIALS REGULATIONS CARRIAGE BY AIRCRAFT General...) Exceptions. This subchapter does not apply to the following materials used for special aircraft operations... aircraft. (4) Hazardous materials are carried and used during dedicated air ambulance, fire fighting, or...
Tropic Test of Bradley Fighting Vehicle Systems.
1985-05-23
CM-R AMSTE-SG-H AMSTE-PT-MT AMSTE-RM Aberden Proving Ground , MD 21005-5055 Commander U.S. Army Armament Research and Development Command ATTN: AMSMC...Requirements Appendix E -Vision Devices Appendix F - Grounding Circuit Resistance Appendix G - Human Factors Appendix H - Distribution List -" -"" 3...miles of operation o Time-on-Target Baseline Tests o Selected electrical and grounding circuit resistances o Armament Firing (25mm, 7.62mm and TOW) o Fire
2011-01-01
we propose that hot-spot mitigation using thermoelectric coolers can be used as a power management mechanism to allow global coolers to be provi...sioned for a better worst case temperature leading to substan- tial savings in cooling power. In order to quantify the potential power savings from us- ing...energy density inside a processor to maximally tolerable levels, modern microprocessors make ex- tensive use of hardware structures such as the load
Firefighter noise exposure during training activities and general equipment use.
Root, Kyle S; Schwennker, Catherine; Autenrieth, Daniel; Sandfort, Delvin R; Lipsey, Tiffany; Brazile, William J
2013-01-01
Multiple noise measurements were taken on 6 types of fire station equipment and 15 types of emergency response vehicle-related equipment used by firefighters during routine and emergency operations at 10 fire stations. Five of the six types of fire station equipment, when measured at a distance of one meter and ear level, emitted noise equal to or greater than 85 dBA, including lawn maintenance equipment, snow blowers, compressors, and emergency alarms. Thirteen of 15 types of equipment located on the fire engines emitted noise levels equal to or greater than 85 dBA, including fans, saws, alarms, and extrication equipment. In addition, noise measurements were taken during fire engine operations, including the idling vehicle, vehicle sirens, and water pumps. Results indicated that idling fire-engine noise levels were below 85 dBA; however, during water pump and siren use, noise levels exceeded 85 dBA, in some instances, at different locations around the trucks where firefighters would be stationed during emergency operations. To determine if the duration and use of fire fighting equipment was sufficient to result in overexposures to noise during routine training activities, 93 firefighter personal noise dosimetry samples were taken during 10 firefighter training activities. Two training activities per sampling day were monitored during each sampling event, for a mean exposure time of 70 min per day. The noise dosimetry samples were grouped based on job description to compare noise exposures between the different categories of job tasks commonly associated with fire fighting. The three job categories were interior, exterior, and engineering. Mean personal dosimetry results indicated that the average noise exposure was 78 dBA during the training activities that lasted 70 min on average. There was no significant difference in noise exposure between each of the three job categories. Although firefighters routinely use equipment and emergency response vehicles that can produce hazardous levels of noise, this study showed that the average noise levels experienced by firefighters was below generally accepted guidelines.
Phytochemicals in the Fight Against Cancer.
Davidson, Kristoffer T; Zhu, Ziwen; Fang, Yujiang
2016-10-01
Phytochemicals are chemical compounds from fruits, vegetables, or grains and they have been used to treat various diseases for thousands of years. More than one million people in the United States get cancer each year. Although recent advances in medicine have improved the outcomes for cancer patients, there is still a need for novel approaches in the fight against cancer. One such approach that has shown promise in recent years is the use of phytochemicals alone or as synergistic agents. In this review, we will discuss the use of phytochemicals as therapeutic agents against cancer with an emphasis on apple extract.
New Agents for the Extinguishment of Magnesium Fires.
1978-04-01
34 23 July 1942. German Patent 724,795. 8. Beythien, R., Wienhaus, H., and von Zehman, H., "Extinguish- ing Magnesium and Other Light Metal Fires ," 12...34Trimethoxyboroxine--An Extinguishing Agent for Metal Fires ," ACS Advances in Chemistry, No. 23, American Chemical Society, Washington, D.C. pp 158...13. Miyashima, Z., "Fire Extinguishing Agent," 7 October 1958. Japanese Patent 8,946. 14. Jenkner, H., "Extinguishing Metal Fires ," 12 September
Toxicokinetics of perfluorooctanoate (PFOA) in rainbow trout(Oncorhynchus mykiss)
Perfluoroalkyl acids (PFAAs) are widely used as stain resistant coatings for cloth, paper, and leather, and as surfactants, fire-fighting foams, and photographic developers. Individual PFAAs have been shown to accumulate in fish and wildlife; however, the extent of this accumulat...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-02
... Reading Room is open from 8 a.m. to 4:30 p.m., Monday through Friday, excluding legal holidays. The...-icers and fire-fighting foams. Safer surfactants are those that break down quickly to non-polluting...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-22
...-HQ-OPPT-2010-0874. The DCO is open from 8 a.m. to 4 p.m., Monday through Friday, excluding legal..., cleaners, airplane deicers, and fire-fighting foams. Safer surfactants are those that break down quickly to...
SCALE-MODEL STUDIES OF MIXING IN DRINKING WATER STORAGE TANKS
Storage tanks and reservoirs are commonly used in drinking water distribution systems to equalize pumping requirements and operating pressures, and to provide emergency water for fire-fighting and pumping outages. Poor mixing in these structures can create pockets of older water...
76 FR 30229 - Shipping Coordinating Committee; Notice of Committee Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-24
.... --Strategy and planning. --Organizational reforms. --Resource management. --Technical Co-operation Fund--biennial allocation to support the ITCP Programme for 2012-2013. --Results-based budget. --Voluntary IMO... FSS Code for communication equipment for fire-fighting teams. --Development of guidelines for use of...
29 CFR 4.130 - Types of covered service contracts illustrated.
Code of Federal Regulations, 2014 CFR
2014-07-01
... services. (8) Chemical testing and analysis. (9) Clothing alteration and repair. (10) Computer services... construction). (17) Film processing. (18) Fire fighting and protection. (19) Fueling services. (20) Furniture...) Guard and watchman security service. (24) Inventory services. (25) Keypunching and keyverifying...
29 CFR 4.130 - Types of covered service contracts illustrated.
Code of Federal Regulations, 2013 CFR
2013-07-01
... services. (8) Chemical testing and analysis. (9) Clothing alteration and repair. (10) Computer services... construction). (17) Film processing. (18) Fire fighting and protection. (19) Fueling services. (20) Furniture...) Guard and watchman security service. (24) Inventory services. (25) Keypunching and keyverifying...
29 CFR 4.130 - Types of covered service contracts illustrated.
Code of Federal Regulations, 2010 CFR
2010-07-01
... services. (8) Chemical testing and analysis. (9) Clothing alteration and repair. (10) Computer services... construction). (17) Film processing. (18) Fire fighting and protection. (19) Fueling services. (20) Furniture...) Guard and watchman security service. (24) Inventory services. (25) Keypunching and keyverifying...
The Adoption of Technological Innovations by Municipal Governments.
ERIC Educational Resources Information Center
Feller, Irwin; Menzel, Donald C.
1978-01-01
Data on the adoption of 43 technological innovations in four service delivery areas were obtained from nationally representative samples of municipal governments. The service delivery areas included fire fighting, solid waste collection and disposal, traffic control, and air pollution control. (Author/RLV)
Depopulation of rural landscapes exacerbates fire activity in the western Amazon.
Uriarte, María; Pinedo-Vasquez, Miquel; DeFries, Ruth S; Fernandes, Katia; Gutierrez-Velez, Victor; Baethgen, Walter E; Padoch, Christine
2012-12-26
Destructive fires in Amazonia have occurred in the past decade, leading to forest degradation, carbon emissions, impaired air quality, and property damage. Here, we couple climate, geospatial, and province-level census data, with farmer surveys to examine the climatic, demographic, and land use factors associated with fire frequency in the Peruvian Amazon from 2000 to 2010. Although our results corroborate previous findings elsewhere that drought and proximity to roads increase fire frequency, the province-scale analysis further identifies decreases in rural populations as an additional factor. Farmer survey data suggest that increased burn scar frequency and size reflect increased flammability of emptying rural landscapes and reduced capacity to control fire. With rural populations projected to decline, more frequent drought, and expansion of road infrastructure, fire risk is likely to increase in western Amazonia. Damage from fire can be reduced through warning systems that target high-risk locations, coordinated fire fighting efforts, and initiatives that provide options for people to remain in rural landscapes.
Depopulation of rural landscapes exacerbates fire activity in the western Amazon
Uriarte, María; Pinedo-Vasquez, Miquel; DeFries, Ruth S.; Fernandes, Katia; Gutierrez-Velez, Victor; Baethgen, Walter E.; Padoch, Christine
2012-01-01
Destructive fires in Amazonia have occurred in the past decade, leading to forest degradation, carbon emissions, impaired air quality, and property damage. Here, we couple climate, geospatial, and province-level census data, with farmer surveys to examine the climatic, demographic, and land use factors associated with fire frequency in the Peruvian Amazon from 2000 to 2010. Although our results corroborate previous findings elsewhere that drought and proximity to roads increase fire frequency, the province-scale analysis further identifies decreases in rural populations as an additional factor. Farmer survey data suggest that increased burn scar frequency and size reflect increased flammability of emptying rural landscapes and reduced capacity to control fire. With rural populations projected to decline, more frequent drought, and expansion of road infrastructure, fire risk is likely to increase in western Amazonia. Damage from fire can be reduced through warning systems that target high-risk locations, coordinated fire fighting efforts, and initiatives that provide options for people to remain in rural landscapes. PMID:23236144
Zeng, Yuanyuan; Sreenan, Cormac J; Sitanayah, Lanny; Xiong, Naixue; Park, Jong Hyuk; Zheng, Guilin
2011-01-01
Fire hazard monitoring and evacuation for building environments is a novel application area for the deployment of wireless sensor networks. In this context, adaptive routing is essential in order to ensure safe and timely data delivery in building evacuation and fire fighting resource applications. Existing routing mechanisms for wireless sensor networks are not well suited for building fires, especially as they do not consider critical and dynamic network scenarios. In this paper, an emergency-adaptive, real-time and robust routing protocol is presented for emergency situations such as building fire hazard applications. The protocol adapts to handle dynamic emergency scenarios and works well with the routing hole problem. Theoretical analysis and simulation results indicate that our protocol provides a real-time routing mechanism that is well suited for dynamic emergency scenarios in building fires when compared with other related work.
Zeng, Yuanyuan; Sreenan, Cormac J.; Sitanayah, Lanny; Xiong, Naixue; Park, Jong Hyuk; Zheng, Guilin
2011-01-01
Fire hazard monitoring and evacuation for building environments is a novel application area for the deployment of wireless sensor networks. In this context, adaptive routing is essential in order to ensure safe and timely data delivery in building evacuation and fire fighting resource applications. Existing routing mechanisms for wireless sensor networks are not well suited for building fires, especially as they do not consider critical and dynamic network scenarios. In this paper, an emergency-adaptive, real-time and robust routing protocol is presented for emergency situations such as building fire hazard applications. The protocol adapts to handle dynamic emergency scenarios and works well with the routing hole problem. Theoretical analysis and simulation results indicate that our protocol provides a real-time routing mechanism that is well suited for dynamic emergency scenarios in building fires when compared with other related work. PMID:22163774
Extinguishing Agent for Magnesium Fire: Phases 5 and 6.
1987-07-01
This report documents the validation testing of the extinguishing system for metal fires developed as part of Phases I-IV. The results of this...system represented a reliable metal fire extinguishing system that could control and extinguish very large metal fires . The specifications developed for...the agent and for the delivery system are discussed in detail. Keywords: Fire suppression, Metal fires , Fire extinguishers.
46 CFR 35.40-10 - Steam, foam, carbon dioxide, or clean agent fire smothering apparatus-TB/ALL.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 1 2013-10-01 2013-10-01 false Steam, foam, carbon dioxide, or clean agent fire... TANK VESSELS OPERATIONS Posting and Marking Requirements-TB/ALL § 35.40-10 Steam, foam, carbon dioxide, or clean agent fire smothering apparatus—TB/ALL. Each steam, foam, carbon dioxide, or clean agent...
46 CFR 35.40-10 - Steam, foam, carbon dioxide, or clean agent fire smothering apparatus-TB/ALL.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 1 2014-10-01 2014-10-01 false Steam, foam, carbon dioxide, or clean agent fire... TANK VESSELS OPERATIONS Posting and Marking Requirements-TB/ALL § 35.40-10 Steam, foam, carbon dioxide, or clean agent fire smothering apparatus—TB/ALL. Each steam, foam, carbon dioxide, or clean agent...
United Nations Human and Financial Resources for Peacekeeping in Africa
1994-06-01
date of proclamation of the cease-fire and will finish when the results of the referendum are declared. As soon as the cease-fire is declared, MINURSO...regional organization, as envisaged in Chapter VII of the Charter." [Ref. 14] On 25 July 1993, a meeting was held in Cotonou (Benin) to establish a new...Abass Bundu (Executive Secretary of ECOWAS), and the leaders of the fighting factions. The Cotonou Agreement was formulated with a clear framework drawn
Development of infrared goggles and prototype
NASA Astrophysics Data System (ADS)
Tsuchimoto, Kouzou; Komatsubara, Shigeyuki; Fujikawa, Masaru; Otsuka, Toshiaki; Kan, Moriyasu; Matsumura, Norihide
2006-05-01
We aimed at developing a hands free type practical wearable thermography which will not hinder walking or working of the person wearing the equipment. We installed a small format camera core module, which was recently developed, into the fire fighter's helmet and incorporated image transmission function over radio to the equipment. We combined this thermography with a see-through type head mount display, and called it "Infrared Goggles". A prototype was developed for verification test of lifesaving support system in fire fighting activities.
2012-06-27
ISS031-E-146344 (27 June 2012) --- An Expedition 31 crew member aboard the International Space Station, flying approximately 240 miles above Earth, recorded a series of images of the current wild fires in the southwestern United States. For this particular image, taken from the station?s Cupola, he used a 16mm lens, which gives this view a ?fisheye? affect. The fires give rise to thick smoke plumes on the southernmost extremity of the Wyoming Range, which occupies the center of the image. Slopes of the central Salt River Range appear at left. Three helicopters and more than 100 personnel are fighting the fire, which is being managed by the Bridger?Teton National Forest.
Antoine-Santoni, Thierry; Santucci, Jean-François; de Gentili, Emmanuelle; Silvani, Xavier; Morandini, Frederic
2009-01-01
The paper deals with a Wireless Sensor Network (WSN) as a reliable solution for capturing the kinematics of a fire front spreading over a fuel bed. To provide reliable information in fire studies and support fire fighting strategies, a Wireless Sensor Network must be able to perform three sequential actions: 1) sensing thermal data in the open as the gas temperature; 2) detecting a fire i.e., the spatial position of a flame; 3) tracking the fire spread during its spatial and temporal evolution. One of the great challenges in performing fire front tracking with a WSN is to avoid the destruction of motes by the fire. This paper therefore shows the performance of Wireless Sensor Network when the motes are protected with a thermal insulation dedicated to track a fire spreading across vegetative fuels on a field scale. The resulting experimental WSN is then used in series of wildfire experiments performed in the open in vegetation areas ranging in size from 50 to 1,000 m2. PMID:22454563
Antoine-Santoni, Thierry; Santucci, Jean-François; de Gentili, Emmanuelle; Silvani, Xavier; Morandini, Frederic
2009-01-01
The paper deals with a Wireless Sensor Network (WSN) as a reliable solution for capturing the kinematics of a fire front spreading over a fuel bed. To provide reliable information in fire studies and support fire fighting strategies, a Wireless Sensor Network must be able to perform three sequential actions: 1) sensing thermal data in the open as the gas temperature; 2) detecting a fire i.e., the spatial position of a flame; 3) tracking the fire spread during its spatial and temporal evolution. One of the great challenges in performing fire front tracking with a WSN is to avoid the destruction of motes by the fire. This paper therefore shows the performance of Wireless Sensor Network when the motes are protected with a thermal insulation dedicated to track a fire spreading across vegetative fuels on a field scale. The resulting experimental WSN is then used in series of wildfire experiments performed in the open in vegetation areas ranging in size from 50 to 1,000 m(2).
29 CFR 1917.118 - Fixed ladders.
Code of Federal Regulations, 2014 CFR
2014-07-01
... tubular scaffold framing; and (4) Ladders used only for fire-fighting or emergency purposes. (b... a ladder, including individual rung ladders, permanently attached to a structure, building or piece... walls of the well. (c) Defects. (1) Ladders with broken, split or missing rungs, steps or rails, broken...
29 CFR 1917.118 - Fixed ladders.
Code of Federal Regulations, 2013 CFR
2013-07-01
... tubular scaffold framing; and (4) Ladders used only for fire-fighting or emergency purposes. (b... a ladder, including individual rung ladders, permanently attached to a structure, building or piece... walls of the well. (c) Defects. (1) Ladders with broken, split or missing rungs, steps or rails, broken...
29 CFR 1917.118 - Fixed ladders.
Code of Federal Regulations, 2012 CFR
2012-07-01
... tubular scaffold framing; and (4) Ladders used only for fire-fighting or emergency purposes. (b... a ladder, including individual rung ladders, permanently attached to a structure, building or piece... walls of the well. (c) Defects. (1) Ladders with broken, split or missing rungs, steps or rails, broken...
Comparative Evaluation of Firefighting Foam Agents
1979-08-01
incorporating these basic concepts under a military specification, are being produced on a world-wide MIL - F - 24385 , Navy (reference 6). basis. The original...Program Office for 24385 (Navy), Fire Extinguishing Aircraft Ground Fire Suppression and Agent, Aqueous- F Ilm-Forming-Foam Rescue, SMF, AGFSkS 71-1...fluoroprotein foams (FPF), and three protein foam (?’ F ) agents. Large-scale fire tests were performed under fixed fire conditions employing air
A Forest Fire Sensor Web Concept with UAVSAR
NASA Astrophysics Data System (ADS)
Lou, Y.; Chien, S.; Clark, D.; Doubleday, J.; Muellerschoen, R.; Zheng, Y.
2008-12-01
We developed a forest fire sensor web concept with a UAVSAR-based smart sensor and onboard automated response capability that will allow us to monitor fire progression based on coarse initial information provided by an external source. This autonomous disturbance detection and monitoring system combines the unique capabilities of imaging radar with high throughput onboard processing technology and onboard automated response capability based on specific science algorithms. In this forest fire sensor web scenario, a fire is initially located by MODIS/RapidFire or a ground-based fire observer. This information is transmitted to the UAVSAR onboard automated response system (CASPER). CASPER generates a flight plan to cover the alerted fire area and executes the flight plan. The onboard processor generates the fuel load map from raw radar data, used with wind and elevation information, predicts the likely fire progression. CASPER then autonomously alters the flight plan to track the fire progression, providing this information to the fire fighting team on the ground. We can also relay the precise fire location to other remote sensing assets with autonomous response capability such as Earth Observation-1 (EO-1)'s hyper-spectral imager to acquire the fire data.
Analysis of Idaho fire service education
NASA Astrophysics Data System (ADS)
Roberts, Walter O.
1999-01-01
Becoming a career fire fighter in the state of Idaho requires specialized knowledge and training. Fire science education at Idaho colleges and universities is available only to people who are affiliated with a fire department. Law enforcement curriculum, on the other hand, is available to any interested persons. A student in law enforcement can attend the Police Officers Standards and Training (POST) academy or participate in classes in one of Idaho's institutions for higher education. There are no fire academies in Idaho. Applicants wanting to become professional fire fighters in Idaho are required to compete with applicants from other states; many of whom have had prior fire education and training. Resident Idaho fire fighter applicants are at a disadvantage when applying for Idaho fire fighting positions. Because of this apparent need, I surveyed the Idaho fire chiefs, using a research instrument I developed in a graduate field research class. I wrote the research instrument to determine the educational needs of the Idaho fire service. The College of Southern Idaho (CSI) and the Idaho Fire Chiefs Association (IFCA) were the recipients of this survey. This report, Analysis of Idaho Fire Service Education, describes that research process from beginning to end.
Extinguishing agent for combustible metal fires
Riley, John F.; Stauffer, Edgar Eugene
1976-10-12
A low chloride extinguishing agent for combustible metal fires comprising from substantially 75 to substantially 94 weight percent of sodium carbonate as the basic fire extinguishing material, from substantially 1 to substantially 5 weight percent of a water-repellent agent such as a metal stearate, from substantially 2 to substantially 10 weight percent of a flow promoting agent such as attapulgus clay, and from substantially 3 to substantially 15 weight percent of a polyamide resin as a crusting agent.
Incidental Reflector Comparison of Containerized Dry Fire Extinguishing Agents
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chapman, Bryan Scott; Wysong, Andrew Russell
This document addresses the incidental reflector reactivity worth of containerized fire extinguishing agents authorized for use in PF-4 at Los Alamos National Laboratory (LANL). The intent of the document is to analyze dry fire extinguishing agent that remains in a container and is not actively being used in a fire emergency. The incidental reflector reactivity worth is determined by comparison to various thicknesses of close fitting water reflection which is commonly used to bound incidental reflectors in criticality safety evaluations. The conclusion is that even in unlimited quantities, when containerized the authorized dry fire extinguishing agents are bound by 0.4more » inches of close fitting water.« less
NASA Astrophysics Data System (ADS)
Katagis, Thomas; Bliziotis, Dimitris; Liantinioti, Chrysa; Gitas, Ioannis Z.; Charalampopoulou, Betty
2016-08-01
During the past decades, forest fires have increased both in frequency and severity thus, increasing the life threats for people and environment and leading countries to spend vast amounts of resources in fighting forest fires. Besides anthropogenic activities, climatic and environmental changes are considered as driving factors affecting fire occurrence and vegetation succession. Especially in the Mediterranean region, the development and existence of effective tools and services is crucial for assisting pre-fire planning and preparedness. The collaborative project NFOFRAS aims at introducing an innovative and effective system for rating forest fire risk, and is based on existing technology and standards that have been developed by countries with a long and a very successful involvement in this field. During the first phase of the project a detailed documentation of the proposed methodology was composed. In addition, Earth Observation (EO) and meteorological datasets were utilized for producing accurate pre-fire measurements over a selected study area in Greece.
NASA Technical Reports Server (NTRS)
2002-01-01
2000 continues to be the worst fire season in the United States in decades. By August 8, 2000, fires in Montana and Idaho had burned more than 250,000 acres. Resources were stretched so thin that Army and Marine soldiers were recruited to help fight the fires. President Clinton visited Payette National Forest to lend moral support to the firefighters. Dense smoke from Idaho and western Montana is visible stretching all the way to North and South Dakota in this image from the Sea-viewing Wide Field-of-view Sensor (SeaWiFS). The image was taken on August 7, 2000. Although the primary mission of SeaWiFS is to measure the biology of the ocean, it also provides stunning color imagery of the Earth's surface. For more information about fires in the U.S., visit the National Interagency Fire Center. To learn more about using satellites to monitor fires, visit Global Fire Monitoring and New Technology for Monitoring Fires from Space in the Earth Observatory. Provided by the SeaWiFS Project, NASA/Goddard Space Flight Center, and ORBIMAGE
Code of Federal Regulations, 2010 CFR
2010-07-01
... convenience of the user, the revised text is set forth as follows: § 570.54 Forest fire fighting and forest... performed, or mining operations. Portable sawmill shall mean a sawmilling operation where no office or...
U.S. Naval Sea Cadet Corps 2009 Annual Report
2009-01-01
Ceremonial Honor Guard CA, NJ, NY, WA (7 classes) Culinary Arts MI, TN, NY (7 classes) Field Training GA, SC, MN (6 classes) Fire Fighting MI, MA (2...the pre- viously established naval engineering, seamanship, culinary arts and operations specialist classes, additional classes in Naval gunners
46 CFR 126.110 - Inspection after accident.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Inspection after accident. 126.110 Section 126.110 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS INSPECTION AND... lifesaving, fire-fighting, or other equipment; or (2) Whenever any important repairs or renewals are made. (b...
14 CFR 23.1197 - Fire extinguishing agents.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire extinguishing agents. 23.1197 Section... test except for built-in carbon dioxide fuselage compartment fire extinguishing systems for which— (1) Five pounds or less of carbon dioxide will be discharged, under established fire control procedures...
14 CFR 25.1197 - Fire extinguishing agents.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire extinguishing agents. 25.1197 Section... test except for built-in carbon dioxide fuselage compartment fire extinguishing systems for which— (1) Five pounds or less of carbon dioxide will be discharged, under established fire control procedures...
NASA Technical Reports Server (NTRS)
2002-01-01
Drought conditions have plagued the Appalachian Mountains in October and November, and low relative humidity combined with dry leaves on the ground has created extreme fire danger in many eastern states. This true-color MODIS image made from data collected on November 13, 2001, shows smoke from numerous fires (indicated in red), predominantly in southern West Virginia (image center), Kentucky (to the southwest), and Tennessee (south). The fires, at least some of which are likely the result of arson, have burned thousands of acres throughout the region. Unfortunately for those people fighting the fires, the fire danger is likely to remain high, with no significant rain expected in the near term. South of Lake Erie, the southernmost of the Great Lakes, numerous aircraft contrails crisscross Ohio. Water vapor emitted with engine exhaust condenses in the cold, dry air at high altitudes, leaving behind a trail of condensation--a contrail. Image courtesy Jacques Descloitres, MODIS Land Rapid Response Team at NASA GSFC
2017-11-01
From left, Jon Wallace, deputy fire coordinator, U.S. Fish and Wildlife Service Southeast Region, Atlanta, Georgia; Chris Wilcox, U.S. Fish and Wildlife chief, Fire Management, National Interagency Fire Center, Boise, Idaho; and Mark Schollmeyer, chief, Brevard County Fire Rescue, pose for a portrait following a ceremony Nov. 1 on the Merritt Island National Wildlife Refuge in Florida. During the joint ceremony, the Spaceport Integration Team and its partners were presented with the prestigious 2017 Pulaski Award and a new memorial marker was dedicated. The multi-agency team includes representatives from NASA's Kennedy Space Center, Cape Canaveral Air Force Station's 45th Space Wing, the Merritt Island National Wildlife Refuge, as well as the Florida Forest Service and Brevard County Fire Rescue. The memorial marker honors two fallen firefighters, Scott Maness and Beau Sauselein, who died fighting a wildfire on space center property in 1981. Held outdoors, the ceremony was attended by 140 guests.
Application of a CO2 dial system for infrared detection of forest fire and reduction of false alarm
NASA Astrophysics Data System (ADS)
Bellecci, C.; Francucci, M.; Gaudio, P.; Gelfusa, M.; Martellucci, S.; Richetta, M.; Lo Feudo, T.
2007-04-01
Forest fires can be the cause of serious environmental and economic damages. For this reason considerable effort has been directed toward forest protection and fire fighting. The means traditionally used for early fire detection mainly consist in human observers dispersed over forest regions. A significant improvement in early warning capabilities could be obtained by using automatic detection apparatus. In order to early detect small forest fires and minimize false alarms, the use of a lidar system and dial technique will be considered. A first evaluation of the lowest detectable concentration will be estimated by numerical simulation. The theoretical model will also be used to get the capability of the dial system to control wooded areas. Fixing the burning rate for several fuels, the maximum range of detection will be evaluated. Finally results of simulations will be reported.
A GIS-based approach for comparative analysis of potential fire risk assessment
NASA Astrophysics Data System (ADS)
Sun, Ying; Hu, Lieqiu; Liu, Huiping
2007-06-01
Urban fires are one of the most important sources of property loss and human casualty and therefore it is necessary to assess the potential fire risk with consideration of urban community safety. Two evaluation models are proposed, both of which are integrated with GIS. One is the single factor model concerning the accessibility of fire passage and the other is grey clustering approach based on the multifactor system. In the latter model, fourteen factors are introduced and divided into four categories involving security management, evacuation facility, construction resistance and fire fighting capability. A case study on campus of Beijing Normal University is presented to express the potential risk assessment models in details. A comparative analysis of the two models is carried out to validate the accuracy. The results are approximately consistent with each other. Moreover, modeling with GIS promotes the efficiency the potential risk assessment.
Fluorotelomer alcohols have been widely used over the past 50 years in surface protection products for paper, packaging, textile, and carpet goods; in industrial surfactant mixtures; in aqueous fire-fighting foams, and as processing aids during the production of fluoropolymer pla...
46 CFR 78.37-3 - Logbooks and records.
Code of Federal Regulations, 2011 CFR
2011-10-01
... completed, the master or person in charge shall file the logbook with the Officer in Charge, Marine... purposes of making entries therein as required by law or regulations in this subchapter. Such logs or... records of tests and inspections of fire fighting equipment must be maintained with the vessel's logs for...
46 CFR 78.37-3 - Logbooks and records.
Code of Federal Regulations, 2010 CFR
2010-10-01
... completed, the master or person in charge shall file the logbook with the Officer in Charge, Marine... purposes of making entries therein as required by law or regulations in this subchapter. Such logs or... records of tests and inspections of fire fighting equipment must be maintained with the vessel's logs for...
A Day as a Scientist: Take Your Child to Work Day | Poster
Do you ever dream you could fight a fire, conduct fascinating experiments, and eat ice cream all in one day? A record number of kids—285 in all—got to do just that during the NCI at Frederick’s annual Take Your Child to Work Day.
75 FR 82219 - Airworthiness Directives; Air Tractor, Inc. Models AT-802 and AT-802A Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-30
... Service Information We reviewed the following service information from Snow Engineering Co.: Service... through -0269, that are: (1) certificated in any category; (2) engaged in agricultural dispersal operations, including those airplanes that have been converted from fire fighting to agricultural dispersal...
33 CFR 150.815 - How must casualties be reported?
Code of Federal Regulations, 2011 CFR
2011-07-01
... the following: (1) Loss of life; (2) An injury that requires professional medical treatment beyond... lifesaving or fire-fighting equipment; or (4) Property damage in excess of $100,000, including damage... Management, Regulation and Enforcement. [USCG-1998-3884, 71 FR 57651, Sept. 29, 2006, as amended by USCG-2011...
75 FR 29507 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-26
... Service Title: Annual Wildfire Report. OMB Control Number: 0596-0025. Summary of Collection: The... information about wildfire suppression efforts by State and local fire fighting agencies in order to support... efforts. FS will collect information using form FS 3100-8, Annual Wildfire Summary Report. Need and Use of...
Outdoor Recreation Activities at Cispus.
ERIC Educational Resources Information Center
Cispus Environmental Center, Randle, WA.
Most of the activities in this booklet have been developed around skills related to the outdoors and, in particular, to the logging industry and forest fire fighting. The activities attempt to develop muscles, coordination skills, and teamwork. They also give the students (junior high school or high school) and staff the opportunity to do…
46 CFR Appendix B to Subpart C of... - Substance Technical Guidelines, Benzene
Code of Federal Regulations, 2013 CFR
2013-10-01
... Subpart C of Part 197—Substance Technical Guidelines, Benzene I. Physical and Chemical Data (a) Substance...) Extinguishing media: Carbon dioxide, dry chemical, or foam. (5) Special fire fighting procedures: Do not use a... engineering). (b) Reactivity. (1) Conditions contributing to instability: Heat. (2) Incompatibility: Heat and...
JPRS Report, Soviet Union: International Affairs.
1988-07-05
Algerian Cinema is Fighting (T.S. Tsarapkina. The Cinema of Algeria. Iskusstvo Publish- ing House, 1986) 9 63 Glukhov S. The Countries of the Persian...DISCUSSION Colonialism under Fire 44 CULTURE, LITERATURE, ART L. Cherkasskiy. China. "Hazy" Poetry 46 N. Chukina. Made by the Hands of Malaysians 48
ERIC Educational Resources Information Center
Zelman, Susan Tave; Cross, Christopher T.
2008-01-01
Crises create heroes. But just as superheroes are always fighting crime, educators spend too much time putting out fires, and frequently do not get to the root of the problem that might have prevented the situation in the first place. The authors advocate for educational organization around four goals: (1) clear expectations for students; (2) the…
Robot Contest as a Laboratory for Experiential Engineering Education
ERIC Educational Resources Information Center
Verner, Igor M.; Ahlgren, David J.
2004-01-01
By designing, building, and operating autonomous robots students learn key engineering subjects and develop systems-thinking, problem-solving, and teamwork skills. Such events as the Trinity College Fire-Fighting Home Robot Contest (TCFFHRC) offer rich opportunities for students to apply their skills by requiring design, and implementation of…
Risks and issues in fire safety on the Space Station
NASA Technical Reports Server (NTRS)
Friedman, Robert
1993-01-01
A fire in the inhabited portion of a spacecraft is a greatly feared hazard, but fire protection in space operations is complicated by two factors. First, the spacecraft cabin is an enclosed volume, which limits the resources for fire fighting and the options for crew escape. Second, an orbiting spacecraft experiences a balance of forces, creating a near-zero-gravity (microgravity) environment that profoundly affects the characteristics of fire initiation, spread, and suppression. The current Shuttle Orbiter is protected by a fire-detection and suppression system whose requirements are derived of necessity from accepted terrestrial and aircraft standards. While experience has shown that Shuttle fire safety is adequate, designers recognize that improved systems to respond specifically to microgravity fire characteristics are highly desirable. Innovative technology is particularly advisable for the Space Station, a forthcoming space community with a complex configuration and long-duration orbital missions, in which the effectiveness of current fire-protection systems is unpredictable. The development of risk assessments to evaluate the probabilities and consequences of fire incidents in spacecraft are briefly reviewed. It further discusses the important unresolved issues and needs for improved fire safety in the Space Station, including those of material selection, spacecraft atmospheres, fire detection, fire suppression, and post-fire restoration.
Persuasion techniques can motivate patients to change eating behaviours, symposium told.
Lechky, O
1995-01-01
Although surveys show that Canadians are concerned about good nutrition, they also reveal that taste and price outrank health concerns when consumers fill their shopping carts. Such attitudes are among the biggest barriers for health care practitioners who are trying to persuade patients to adopt a balanced diet that is low in fat and sugar and high in fibre. A marketing-communications expert says physicians and dietitians can fight fire with fire by adopting persuasion strategies that have been used successfully by advertisers to sell food products. PMID:7859207
Testing of Fire Fighting Foam.
1980-11-01
for Fresh and Sea Water ( MIL - F - 24385 ); -(C) Underwriters Laboratories Inc. S andard for Air Foam Equipment and Liquid Con- centrates (UL162);4D...C. Test Facilities 6 D. Test Procedures 7 III. Results of Tests A. FRN-1007 33 B. MIL - F - 24385 34 C. UL 162 34 D. O- F -555C 35 E. Foam Quality 35 IV...1 gpm) H N-heptane in. inch (25.4 mm = 1 in.) ipm liters per minute M Motor Octane Rating MIL MIL - F - 24385 Test Method NFPA National Fire Protection
The effects of ultraviolet-B radiation on the toxicity of fire-fighting chemicals
Calfee, R.D.; Little, E.E.
2003-01-01
The interactive effects of ultraviolet (UV) and fire-retardant chemicals were evaluated by exposing rainbow trout (Oncorhyncus mykiss) juveniles and tadpoles of southern leopard frogs (Rana sphenocephala) to six fire-retardant formulations with and without sodium ferrocyanide (yellow prussiate of soda [YPS]) and to YPS alone under three simulated UV light treatments. Yellow prussiate of soda is used as a corrosion inhibitor in some of the fire-retardant chemical formulations. The underwater UV intensities measured were about 2 to 10% of surface irradiance measured in various aquatic habitats and were within tolerance limits for the species tested. Mortality of trout and tadpoles exposed to Fire-Trol?? GTS-R, Fire-Trol 300-F, Fire-Trol LCA-R, and Fire-Trol LCA-F was significantly increased in the presence of UV radiation when YPS was present in the formulation. The boreal toad (Bufo boreas), listed as endangered by the state of Colorado (USA), and southern leopard frog were similar in their sensitivity to these chemicals. Photoenhancement of fire-retardant chemicals can occur in a range of aquatic habitats and may be of concern even when optical clarity of water is low; however, other habitat characteristics can also reduce fire retardant toxicity.
Analysis of the prescribed burning practice in the pine forest of northwestern Portugal.
Fernandes, P; Botelho, H
2004-01-01
The ignition of low-intensity fires in the dormant season in the pine stands of north-western Portugal seeks to reduce the existing fuel hazard without compromising site quality. The purpose of this study is to characterise this practice and assess its effectiveness, based on information resulting from the normal monitoring process at the management level, and using operational guidelines, fire behaviour models and a newly developed method to classify prescribed fire severity. Although the region's humid climate strongly constrains the activity of prescribed fire, 87% of the fires analysed were undertaken under acceptable meteorological and fuel moisture conditions. In fact, most operations achieved satisfactory results. On average, prescribed fire reduces by 96% the potential intensity of a wildfire occurring under extreme weather conditions, but 36% of the treated sites would still require heavy fire fighting resources to suppress such fire, and 17% would still carry it in the tree canopy. Only 10% of the prescribed burns have an excessive impact on trees or the forest floor, while 89% (normal fire weather) or 59% (extreme fire weather) comply with both ecological integrity maintenance and wildfire protection needs. Improved planning and monitoring procedures are recommended in order to overcome the current deficiencies.
Wood crib fire free burning test in ISO room
NASA Astrophysics Data System (ADS)
Qiang, Xu; Griffin, Greg; Bradbury, Glenn; Dowling, Vince
2006-04-01
In the research of application potential of water mist fire suppression system for fire fighting in train luggage carriage, a series of experiments were conducted in ISO room on wood crib fire with and without water mist actuation. The results of free burn test without water mist suppression are used as reference in evaluating the efficiency of water mist suppression system. As part of the free burn test, several tests have been done under the hood of ISO room to calibrate the size of the crib fire and these tests can also be used in analyzing the wall effect in room fire hazard. In these free burning experiments, wood cribs of four sizes under the hood were tested. The temperature of crib fire, heat flux around the fire, gas concentration in hood of ISO room were measured in the experiments and two sets of thermal imaging system were used to get the temperature distribution and the typical shape of the free burning flames. From the experiments, the radiation intensity in specific positions around the fire, the effective heat of combustion, mass loss, oxygen consumption rate for different sizes of fire, typical structure of the flame and self extinguishment time was obtained for each crib size.
Extinguishing agent for magnesium fire, phases 5 and 6
NASA Astrophysics Data System (ADS)
Beeson, H. D.; Tapscott, R. E.; Mason, B. E.
1987-07-01
This report documents the validation testing of the extinguishing system for metal fires developed as part of Phases 1 to 4. The results of this validation testing form the basis of information from which draft military specifications necessary to procure the agent and the agent delivery system may be developed. The developed system was tested against a variety of large-scale metal fire scenarios and the capabilities of the system were assessed. In addition the response of the system to storage and to changes in ambient conditions was tested. Results of this testing revealed that the developed system represented a reliable metal fire extinguishing system that could control and extinguish very large metal fires. The specifications developed for the agent and for the delivery system are discussed in detail.
[A major game in the re-organization of the Professional Nursing School].
de Amorin, Wellington Mendonça; Barreira, Ieda de Alencar
2007-01-01
This is a historical-social description study supported on the thought of Pierre Bourdieu based on documental analysis. It describes the sanitarists and psychiatrists' actions from the reformulation of Education and Public Health Ministry into Education and Health Ministry in the beginning of New State and analyse the fight's strategies of the main agents to take advantage on their proposals of Professional Nursing School's reorganization. The fight's strategies that psychiatrists, sanitarists and certificated nurses had used to stake their projects, characterized a difficult battle inserted in a hard major game. The analyse of the ten course's months of the main document shows the conflict between those agents to impose a new rule to the school.
The Effect of Extinguishing Agents on Burning Sonobuoys Containing Lithium-Sulfur Dioxide Batteries
1989-09-01
components and the JP-5. In addition, the types of extinguish- ment materials, such as carbor spheres, that have some degree of success on metal fires , would...NWC TP 6571, publication UNCLASSIFIED.) 8. John F. Riley. "Na-X, a New Fire Extinguishing Agent for Metal Fires ," Fire Technology, Vol. 10, No. 4
Environmentally Safer, Less Toxic Fire-Extinguishing Agents
NASA Technical Reports Server (NTRS)
Parrish, Clyde F.
2003-01-01
Fire-extinguishing agents comprising microscopic drops of water microencapsulated in flame-retardant polymers have been proposed as effective, less toxic, non-ozone-depleting, non-globalwarming alternatives to prior fire-extinguishing agents. Among the prior fire-extinguishing agents are halons (various halocarbon fluids), which are toxic and contribute both to depletion of upperatmospheric ozone and to global warming. Other prior fire-extinguishing agents are less toxic and less environmentally harmful but, in comparison with halons, are significantly less effective in extinguishing fires. The proposal to formulate new waterbased agents is based on recent success in the use of water mist as a fire-suppression agent. Water suppresses a flame by reducing the flame temperature and the concentration of oxygen available for the combustion process. The temperature is reduced because the water droplets in the mist absorb latent heat of vaporization as they evaporate. The concentration of oxygen is reduced because the newly generated water vapor displaces air. Unfortunately, water mists are difficult to produce in confined spaces and can evaporate before they reach the bases of flames. The proposal addresses both of these issues: The proposed fire-extinguishing agents would be manufactured in microencapsulated form in advance, eliminating the problem of generating mists in confined spaces. Because of the microencapsulation, the droplets would not evaporate until exposed directly to the heat of flames. In addition, the proposal calls for the introduction of free radicals that would inhibit the propagation of the chemical reactions of the combustion reactions. Manufacturing of a fire-extinguishing agent according to the proposal would begin with the formulation of a suitable polymer (e.g., a polybromostyrene) that would contribute free radicals to the combustion process. The polymer would be dissolved in a suitable hydrocarbon liquid (e.g., toluene). Water would be dispersed in the polymer/toluene solution, then another hydrocarbon liquid (e.g., hexane) that is not a solvent for the polymer would be added to the mixture to make the dissolved polymer precipitate onto the water droplets. The resulting polymer-coated droplets would be removed from the coating mixture by filtration, dried, and stored for use.
14 CFR 121.265 - Fire-extinguishing agents.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Fire-extinguishing agents. 121.265 Section...-extinguishing agents. Only methyl bromide, carbon dioxide, or another agent that has been shown to provide... satisfactory recharging equipment. If carbon dioxide is used, it must not be possible to discharge enough gas...
Codified Knowledge and Embodied Learning: The Problem of Safety Training
ERIC Educational Resources Information Center
Somerville, Margaret; Lloyd, Anne
2006-01-01
The research that informs this article was focused around the relationship between how workers are trained to work safely and how workers learn to work safely in the workplace. The findings of empirical studies into learning and practising safety in aged care, fire fighting, building construction, and mining industries are summarized. A common…
46 CFR 35.07-5 - Logbooks and records-TB/ALL.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., the master or person in charge shall file the logbook with the Officer in Charge, Marine Inspection... purposes of making entries therein as required by law or regulations in this subchapter. Such logs or... records of tests and inspections of fire fighting equipment must be maintained with the vessel's logs for...
46 CFR 35.07-5 - Logbooks and records-TB/ALL.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., the master or person in charge shall file the logbook with the Officer in Charge, Marine Inspection... purposes of making entries therein as required by law or regulations in this subchapter. Such logs or... records of tests and inspections of fire fighting equipment must be maintained with the vessel's logs for...
Credit PSR. This interior view of the building equipment room ...
Credit PSR. This interior view of the building equipment room displays heat exchangers and fan units with insulated piping for hot and cold water at left. Environmental controls and fire fighting system controls appear at right - Jet Propulsion Laboratory Edwards Facility, Propellant Curing Building, Edwards Air Force Base, Boron, Kern County, CA
2 More Universities Settle with Cuomo in Lender Controversy
ERIC Educational Resources Information Center
Field, Kelly; Keller, Josh
2007-01-01
The ever-expanding investigation into conflicts of interest between colleges and lenders continued to claim victims last week as two more universities settled with New York State's attorney general, and another fired its financial-aid director. Drexel University, the only institution that had said it would fight allegations over its student-loan…
Aeronautics and Space Highlights [1979 Highlights
NASA Technical Reports Server (NTRS)
1979-01-01
The videotape includes footage of the following: Voyagers to Jupiter, Pioneer to Saturn, High Energy Astronomy Observatory, space telescope, space shuttle, astronauts Young and Crippen, 10th anniversary of Apollo 11, Skylab reentry, Landsat, satellite freeze warning, Fire Fighting Module, SAGE, wind generators, Solar Energy Project, electric car research, XV-15, HiMAT, and crash worthiness tests.
20. HANGAR BAY #2 FORWARD LOOKING AFT ON CENTERLINE ...
20. HANGAR BAY #2 - FORWARD LOOKING AFT ON CENTERLINE - STARBOARD SIDE SHOWING CONFLAGRATION STATION, UPTAKE SPACE AND DEHUMIDIFICATION MACHINES - PORT SIDE SHOWING VARIOUS DECK WINCHES, ROLLER DOORS, HANGAR DECK PLANE CONTROL STATION AND AQUEOUS FIRE FIGHTING FOAM HOSE REELS. - U.S.S. HORNET, Puget Sound Naval Shipyard, Sinclair Inlet, Bremerton, Kitsap County, WA
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-16
... regulations allow. Because manufacturers have not yet developed respiratory protection for this occupational...-approved filtering facepiece respirators which are not designed for this use, or no respiratory protection... respiratory protective devices designed for the inhalation hazards of this occupational setting. On July 10...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Griffith, B.; Pless, S.; Talbert, B.
2003-07-01
A new/proposed building for the Teterboro Airport was selected as a case study for High Performance Building Initiative research efforts. This report documents research-level energy analysis conducted on the Teterboro Airport building during predesign and design phases of the project.
Review and Analysis of Curricula For Occupations in Public Services. Information Series No. 29.
ERIC Educational Resources Information Center
Lewis, Wiley B.
To identify major findings, promising developments, strategies, and methodological strengths and weaknesses which exist in curricula designed for training paraprofessional public service workers in the fields of education, social work, law enforcement, and fire fighting, a review and analysis was made of Educational Resources Information Center…
Fighting Fires in Early Intervention Supervision: Trading the Axe for Mr. Rogers's Slippers
ERIC Educational Resources Information Center
Alexander, Laura; Gallen, Robert T.; Salazar, Ruby; Shahmoon-Shanok, Rebecca
2012-01-01
When Pennsylvania's Early Intervention system implemented an early intervention-reflective supervision project, modest expectations for change were anticipated, given the limited amount of time and funding for the project. In this article, one participant tells the story of her professional development, which enabled her to augment her skills as…
Gianfaldoni, S; Wollina, U; Lotti, J; Gianfaldoni, R; Lotti, T; Fioranelli, M; Roccia, M G
To retrieve the history of venous ulcers and of skin lesions in general, we must go back to the appearance of human beings on earth. It is interesting to note that cutaneous injuries evolved parallel to human society. An essential first step in the pathogenesis of ulcers was represented by the transition of the quadruped man to Homo Erectus. This condition was characterized by a greater gravitational pressure on the lower limbs, with consequences on the peripheral venous system. Furthermore, human evolution was characterized by an increased risk of traumatic injuries, secondary to his natural need to create fire and hunt (e.g. stones, iron, fire, animal fighting). Humans then began to fight one another until they came to real wars, with increased frequency of wounds and infectious complications. The situation degraded with the introduction of horse riding, introduced by the Scites, who first tamed animals in the 7th century BC. This condition exhibited iliac veins at compression phenomena, favouring the venous stasis. With time, man continued to evolve until the modern age, which is characterized by increased risk factors for venous wounds such as poor physical activity and dietary errors (1, 2).
Gary Achtemeier
2012-01-01
A cellular automata fire model represents âelementsâ of fire by autonomous agents. A few simple algebraic expressions substituted for complex physical and meteorological processes and solved iteratively yield simulations for âsuper-diffusiveâ fire spread and coupled surface-layer (2-m) fireâatmosphere processes. Pressure anomalies, which are integrals of the thermal...
A short history of fires and explosions caused by anaesthetic agents.
MacDonald, A G
1994-06-01
The first recorded fire resulting from the use of an anaesthetic agent occurred in 1850, when ether caught fire during a facial operation. Many subsequent fires and explosions have been reported, caused by ether, acetylene, ethylene and cyclopropane, and there has been one reported explosion involving halothane. Although some of the earlier incidents caused more consternation than injury, many of the later ones caused much death and destruction, particularly after the practice of administering oxygen, instead of air, became established. Many incidents have never been reported and many of those which have reached publication do not record essential details. The use of flammable agents has decreased significantly in recent years and although fires and explosions from nonanaesthetic causes, for example gastrointestinal gases, skin sterilizing agents and laser surgery, may continue to occur, those from gaseous and volatile anaesthetic agents may now be of historical interest only. This article reviews some of the more relevant and enlightening reports of the past 150 yr.
46 CFR 35.40-10 - Steam, foam, carbon dioxide, or clean agent fire smothering apparatus-TB/ALL.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 1 2012-10-01 2012-10-01 false Steam, foam, carbon dioxide, or clean agent fire smothering apparatus-TB/ALL. 35.40-10 Section 35.40-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS OPERATIONS Posting and Marking Requirements-TB/ALL § 35.40-10 Steam, foam, carbon dioxide, or clean agent fire smothering apparatus—TB...
2012-06-27
ISS031-E-146343 (27 June 2012) --- An Expedition 31 crew member aboard the International Space Station, flying approximately 240 miles above Earth, recorded a series of images of the current wild fires in the west and southwestern United States. For this particular image, taken from the station?s Cupola, he used a 16mm lens, which gives this view a ?fisheye? affect. The fires give rise to thick smoke plumes on the southernmost extremity of the Wyoming Range, which occupies the bottom left portion of the image. Three helicopters and more than 100 personnel are fighting the fire, which is being managed by the Bridger?Teton National Forest. Part of a docked Russian Soyuz spacecraft and the Multi-Purpose Logistics Module (MPLM) are at lower right.
Design and analysis of roll cage
NASA Astrophysics Data System (ADS)
Angadi, Gurusangappa; Chetan, S.
2018-04-01
Wildlife fire fighting vehicles are used to extinguish fires in forests, in this process vehicles face falling objects like rocks, tree branches and other objects. Also due to uneven conditions of the terrain like cliff edges, uneven surfaces etc. makes the vehicle to roll over and these can cause injuries to both the driver and the operator. Roll over of a vehicle is a common incident which makes fatal injuries to the operator and also stands next to the crash accidents. In order to reduce the injury level and continuous roll over of the vehicle it is necessary to equip suitable roll cage according to standards of vehicle. In this present work roll cage for pump operator in wildfire fighting vehicle is designed and analysis is carried out in computer simulated environment when seating position of operator seated outside of the cabin. According to NFPA 1906 standards wildlife fire apparatus, Design and Test procedures that are carried out in Hyperworks maintaining SAE J1194.1983 standards. G load case, roof crush analysis and pendulum impact analysis tests are carried out on roll cage to ensure the saftey of design. These load cases are considerd to satisfy the situation faced in forest terrain. In these test procedures roll cage is analysed for stresses and deformation in various load cases. After recording results these are compared with standards mentioned in SAE J1194.1983.
Urban fire risk control: House design, upgrading and replanning
Mbuya, Elinorata Celestine
2018-01-01
Urbanisation leads to house densification, a phenomenon experienced in both planned and unplanned settlements in cities in developing countries. Such densification limits fire brigade access into settlements, thereby aggravating fire disaster risks. In this article, we assess the fire exposure and risks in residences in informal areas of Mchikichini ward, in Dar es Salaam City, Tanzania. We rely on interviews of residents and government officials to obtain background on the occurrence and causes of fire accidents, policy provisions and regulations, and experiences with fire outbreaks and coping strategies, as well as on observations and measurements of house transformations, spatial quality and indoor real life. Our findings suggest that fire risks arise from both inappropriate structural characteristics and unsound behavioural practices. This includes unsafe electric practices by residents, poor capacity of residents to fight fires once started, limited access to structures by firefighting equipment because of flouting of planning regulations and inadequate awareness of local government leaders of the magnitude of fire risks. Potential changes to reduce fire risks in the settlement include the installation of firefighting systems, restriction of cooking to designated spaces, use of safer cooking energy sources and lighting means, improvements of vehicle access routes to neighbourhoods, capacity building at the grass root level and the establishment of community-based fire risk management.
Hodous, T; Pizatella, T; Braddee, R; Castillo, D
2004-01-01
Objective: To review the causes of all fire fighter line-of-duty-deaths from 1998 through 2001, and present recommendations for preventing fatalities within the specific subgroup of structure related events. Methods: Fire fighter fatality data from the United States Fire Administration were reviewed and classified into three main categories of injury. Investigations conducted through the National Institute for Occupational Safety and Health (NIOSH) Fire Fighter Fatality Investigation and Prevention Program provided the basis for the recommendations presented in this paper. Results: During the time period from 1998–2001, there were 410 line-of-duty deaths among fire fighters in the United States, excluding the 343 fire fighters who died at the World Trade Center on 11 September 2001. The 410 fatalities included 191 medical (non-traumatic) deaths (47%), 75 motor vehicle related fatalities (18%), and 144 other traumatic fatalities (35%). The latter group included 68 fatalities that were associated with structures which commonly involved structural collapse, rapid fire progression, and trapped fire fighters. Conclusions: Structural fires pose particular hazards to fire fighters. Additional efforts must be directed to more effectively use what we have learned through the NIOSH investigations and recommendations from published experts in the safety community, consensus standards, and national fire safety organizations to reduce fire fighter fatalities during structural fire fighting. PMID:15314049
The Applicability of Army Design Methodology to the Federal Bureau of Investigation
2011-05-19
fighting crime , terrorism and espionage, while responding to new threats by organizing, equipping and adapting. Throughout the gangster era of the 1930s...the FBI armed its agents for the first time, and organized itself to fight gangsters who were accustomed to committing violent crimes and crossing...to transform the FBI into an effective domestic intelligence agency with the goal of preventing terrorist attacks and serious crime .7 These efforts
NASA Technical Reports Server (NTRS)
Ruff, Gary A.
2004-01-01
This report is concerned with the following topics regarding fire suppression:What is the relative effectiveness of candidate suppressants to extinguish a representative fire in reduced gravity, including high-O2 mole fraction, low -pressure environments? What are the relative advantages and disadvantages of physically acting and chemically-acting agents in spacecraft fire suppression? What are the O2 mole fraction and absolute pressure below which a fire cannot exist? What effect does gas-phase radiation play in the overall fire and post-fire environments? Are the candidate suppressants effective to extinguish fires on practical solid fuels? What is required to suppress non-flaming fires (smoldering and deep seated fires) in reduced gravity? How can idealized space experiment results be applied to a practical fire scenario? What is the optimal agent deployment strategy for space fire suppression?
Fire suppression in human-crew spacecraft
NASA Technical Reports Server (NTRS)
Friedman, Robert; Dietrich, Daniel L.
1991-01-01
Fire extinguishment agents range from water and foam in early-design spacecraft (Halon 1301 in the present Shuttle) to carbon dioxide proposed for the Space Station Freedom. The major challenge to spacecraft fire extinguishment design and operations is from the micro-gravity environment, which minimizes natural convection and profoundly influences combustion and extinguishing agent effectiveness, dispersal, and post-fire cleanup. Discussed here are extinguishment in microgravity, fire-suppression problems anticipated in future spacecraft, and research needs and opportunities.
Applications of Near Real-Time Image and Fire Products from MODIS
NASA Astrophysics Data System (ADS)
Schmaltz, J. E.; Ilavajhala, S.; Teague, M.; Ye, G.; Masuoka, E.; Davies, D.; Murphy, K. J.; Michael, K.
2010-12-01
NASA’s MODIS Rapid Response Project (http://rapidfire.sci.gsfc.nasa.gov/) has been providing MODIS fire detections and imagery in near real-time since 2001. The Rapid Response system is part of the Land and Atmospheres Near-real time Capability for EOS (LANCE-MODIS) system. Current capabilities include providing MODIS imagery in true color and false color band combinations, a vegetation index, and temperature - in both uncorrected swath format and geographically corrected subset regions. The geographically-corrected subsets images cover the world's land areas and adjoining waters, as well as the entire Arctic and Antarctic. These data are available within a few hours of data acquisition. The images are accessed by large number of user communities to obtain a rapid, 250 meter-resolution overview of ground conditions for fire management, crop and famine monitoring and forecasting, disaster response (fires, oil spills, floods, storms), dust and aerosol monitoring, aviation (tracking volcanic ash), monitoring sea ice conditions, environmental monitoring, and more. In addition, the scientific community uses imagery to locate phenomena of interest prior to ordering and processing data and to support the day-to-day planning of field campaigns. The MODIS Rapid Response project has also been providing a near real-time data feed on fire locations and MODIS imagery subsets to the Fire Information for Resource Management System (FIRMS) project (http://maps.geog.umd.edu/firms). FIRMS provides timely availability of fire location information, which is essential in preventing and fighting large forest/wild fires. Products are available through a WebGIS for visualizing MODIS hotspots and MCD45 Burned Area images, an email alerting tool to deliver fire data on daily/weekly/near real-time basis, active data downloads in formats such as shape, KML, CSV, WMS, etc., along with MODIS imagery subsets. FIRMS’ user base covers more than 100 countries and territories. A recent user survey showed that a majority of people use FIRMS for the purposes of conservation, fire-fighting, natural hazard monitoring, land cover change monitoring, and climate change. FIRMS has also developed a cellphone-based text (SMS) alerting of MODIS and MSG-detected fires in near real-time in South Africa, in partnership with the South African power company ESKOM and Council of Scientific and Industrial Research, South Africa. FIRMS was transitioned to the United Nations Food and Agricultural Organization (UN-FAO) in Rome, Italy in Spring 2010 and is scheduled to become a part of the LANCE-MODIS data system (http://lance.nasa.gov/) in Spring 2011.
Thomas A. Spies; Eric White; Alan Ager; Jeffrey D. Kline; John P. Bolte; Emily K. Platt; Keith A. Olsen; Robert J. Pabst; Ana M. G. Barros; John D. Bailey; Susan Charnley; Anita T. Morzillo; Jennifer Koch; Michelle M. Steen-Adams; Peter H. Singleton; James Sulzman; Cynthia Schwartz; Blair Csuti
2017-01-01
Fire-prone landscapes present many challenges for both managers and policy makers in developing adaptive behaviors and institutions. We used a coupled human and natural systems framework and an agent-based landscape model to examine how alternative management scenarios affect fire and ecosystem services metrics in a fire-prone multiownership landscape in the eastern...
Materials Applications for Non-Lethal: Aqueous Foams
DOE Office of Scientific and Technical Information (OSTI.GOV)
GOOLSBY,TOMMY D.; SCOTT,STEVEN H.
High expansion aqueous foam is an aggregation of bubbles that has the appearance of soap suds and is used to isolate individuals both visually and acoustically. It was developed in the 1920's in England to fight coal mine fires and has been widely used since for fire fighting and dust suppression. It was developed at Sandia National Laboratories (SNL) in the 1970's for nuclear safeguards and security applications. In the mid-1990s, the National Institute of Justice (NIJ), the research arm of the Department of Justice, began a project with SNL to determine the applicability of high expansion aqueous foam formore » correctional applications. NIJ funded the project as part of its search for new and better less-than-lethal weapons for responding to violent and dangerous individuals, where other means of force could lead to serious injuries. The phase one objectives of the project were to select a low-to-no toxicity foam concentrate (foaming agent) with physical characteristics suited for use in a single cell or large prison disturbances, and to determine if the selected foam concentrate could serve as a carrier for Oleoresin Capsicum (OC) irritant. The phase two objectives were to conduct an extensive toxicology review of the selected foam concentrate and OC irritant, and to conduct respiration simulation experiments in the selected high expansion aqueous foam. The phase three objectives were to build a prototype individual cell aqueous foam system and to study the feasibility of aqueous foams for large prison facility disturbances. The phase four and five objectives were to use the prototype system to do large scale foam physical characteristics testing of the selected foam concentrate, and to have the prototype single cell system further evaluated by correctional representatives. Prison rather than street scenarios were evaluated as the first and most likely place for using the aqueous foam since prisons have recurrent incidents where officers and inmates might be seriously injured during violent confrontations. The very low density of the high expansion foam also makes it more suitable for indoor use. This paper summarizes the results of the project.« less
Hagenaars, A; Meyer, I J; Herzke, D; Pardo, B G; Martinez, P; Pabon, M; De Coen, W; Knapen, D
2011-08-01
Fluorosurfactants are the key components in aqueous film forming foams (AFFF). They provide these fire fighting agents with the required low surface tension and they enable film formation on top of lighter fuels to prevent burn back. Development of effective and environmentally acceptable PFOS alternatives is one of the most important priorities in the fire fighting foam industry. DuPont™ offers the fluorosurfactant mixtures Forafac(®)1157 and Forafac(®)1157N for the formulation of AFFFs which are alternatives to the persistent and toxic perfluorooctane sulphonate (PFOS). Ecotoxicological testing of these inadequately documented mixtures is necessary to include them in AFFF hazard and risk assessment. Juvenile turbot (Scophthalmus maximus) were exposed for 14 days to 0.1; 0.5 and 1.5mg/L of the fluorosurfactant mixtures used in Forafac(®)1157 and Forafac(®)1157N. In an initial transcriptomics experiment, microarray analysis revealed differentially expressed transcripts of genes which were mainly involved in digestion and in the immune system. This discovery-driven screening approach offered the basis for new hypotheses that were tested in two subsequent experiments in which food intake, energy reserves, growth and a set of haematological parameters were examined. Additionally, effects of the two mixtures were compared to those of PFOS. Based on the results of this study, the mode of action of Forafac(®)1157N was the activation of the acute phase reaction resulting in increased leukocyte concentrations and the inhibition of growth due to the high energetic cost of toxicant exposure. For Forafac(®)1157, evidences of immunosuppression were found on the transcriptional level and the altered differential leukocyte profiles indicated that stress was induced in these fish. However, food intake, energy reserves and growth were not compromised, even at high exposure concentrations, which was in contrast to the effects seen after PFOS exposure. Taking into account that Forafac(®)1157 appeared to be less toxic than PFOS, this mixture could be considered as a more environmentally acceptable PFOS alternative for the use in AFFFs. Copyright © 2011 Elsevier B.V. All rights reserved.
2015-12-01
43 1.9 Images of Move Under Direct Fire (Task 10) 44 1.10 Engage Targets with a .50 Caliber M2 Machine Gun (Task 12) 45 1.11 Image of Lay a...Caliber M2 Machine Gun While wearing a fighting load (approximately 83 lb) and working as a member of a two-person team, Soldiers lifted and carried the... M2 HB Machine Gun with tripod (153 lb) a distance of 10 m. Army Standard: Successful completion of the task 13. Emplace Base Plate (11C
2015-12-01
25mm barrel install (Task 5) and engage targets with an M2 machine gun (Task 12). During these tasks, the performance of one individual will affect...TOW Missile Launcher on BFV (Task 8) 43 1.9 Images of Move Under Direct Fire (Task 10) 44 1.10 Engage Targets with a .50 Caliber M2 Machine Gun ...Engage Targets with a .50 Caliber M2 Machine Gun While wearing a fighting load (approximately 83 lb) and working as a member of a two-person team
Application of Paste Backfill in Underground Coal Fires
NASA Astrophysics Data System (ADS)
Masniyom, M.; Drebenstedt, C.
2009-04-01
Coal fires are known from different coalfields worldwide. China, India, USA, Australia, Indonesia and South Africa are the main countries affected by coal fires. The fires is thermally intensive and cause numerous sinkholes, large-scale subsidence, air pollution, global warming, loss of mining productivity and increasing safety risk. The Wuda Inner Mongolia coalfield has been selected as a possible test area for paste backfill. The traditional methods, executed by fire fighting teams, by covering the coalfire areas with soil, blasting burning coal outcrops and injecting water in the subsurface fire pockets are continuously improved and extended. Initiatives to introduce modern techniques, such as backfill placement at fracture and borehole, to cool down the burning coal and cut off the air supply. This study is to investigate backfill materials and techniques suited for underground coal fires. Laboratory tests were carried out on physical, chemical and mechanical properties of different backfill materials and mixtures thereof. Special attention was paid to materials generated as by-products and other cheaply available materials e.g. fly ash from power plants. There is a good chance that one of the different material mixtures investigated can be used as a technically and economically viable backfill for underground coal fires.
2017-11-01
From left, Jon Wallace, deputy fire coordinator, U.S. Fish and Wildlife Service Southeast Region, Atlanta, Georgia; Chris Wilcox, U.S. Fish and Wildlife chief, Fire Management, National Interagency Fire Center, Boise, Idaho; and John Fish, chief, Florida Forest Service, pose for a portrait following a ceremony Nov. 1 on the Merritt Island National Wildlife Refuge in Florida. During the joint ceremony, the Spaceport Integration Team and its partners were presented with the prestigious 2017 Pulaski Award and a new memorial marker was dedicated. The multi-agency team includes representatives from NASA's Kennedy Space Center, Cape Canaveral Air Force Station's 45th Space Wing, the Merritt Island National Wildlife Refuge, as well as the Florida Forest Service and Brevard County Fire Rescue. The memorial marker honors two fallen firefighters, Scott Maness and Beau Sauselein, who died fighting a wildfire on space center property in 1981. Held outdoors, the ceremony was attended by 140 guests.
2017-11-01
From left, Jon Wallace, deputy fire coordinator, U.S. Fish and Wildlife Service Southeast Region, Atlanta, Georgia; Chris Wilcox, U.S. Fish and Wildlife chief, Fire Management, National Interagency Fire Center, Boise, Idaho; and Kelvin Manning, associate director, NASA's Kennedy Space Center, pose for a portrait following a ceremony Nov. 1 on the Merritt Island National Wildlife Refuge in Florida. During the joint ceremony, the Spaceport Integration Team and its partners were presented with the prestigious 2017 Pulaski Award and a new memorial marker was dedicated. The multi-agency team includes representatives from NASA's Kennedy Space Center, Cape Canaveral Air Force Station's 45th Space Wing, the Merritt Island National Wildlife Refuge, as well as the Florida Forest Service and Brevard County Fire Rescue. The memorial marker honors two fallen firefighters, Scott Maness and Beau Sauselein, who died fighting a wildfire on space center property in 1981. Held outdoors, the ceremony was attended by 140 guests.
NASA Astrophysics Data System (ADS)
Bellecci, C.; De Leo, L.; Gaudio, P.; Gelfusa, M.; Lo Feudo, T.; Martellucci, S.; Richetta, M.
2006-09-01
Forest fires can be the cause of serious environmental and economic damages. For this reason a considerable effort has been directed toward the forest protection and fire fighting. In the early forest fire detection, Lidar technique present considerable advantages compared to the passive detection methods based on infrared cameras currently in common use, due its higher sensitivity and ability to accurately locate the fire. The combustion phase of the vegetable matter causes a great amount of water vapour emission, thus the water molecule behaviour will be studied to obtain a fire detection system ready and efficient also before the flame propagation. A first evaluation of increment of the water vapour concentration compared to standard one will be estimated by a numerical simulation. These results will be compared with the experimental measurements carried out into a cell with a CO II Dial system, burning different kinds of vegetable fuel. Our results and their comparison will be reported in this paper.
46 CFR 131.815 - Carbon dioxide and clean agent alarms.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Carbon dioxide and clean agent alarms. 131.815 Section 131.815 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.815 Carbon dioxide and clean agent alarms. Each carbon dioxide or clean agent fire...
46 CFR 131.815 - Carbon dioxide and clean agent alarms.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Carbon dioxide and clean agent alarms. 131.815 Section 131.815 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.815 Carbon dioxide and clean agent alarms. Each carbon dioxide or clean agent fire...
46 CFR 131.815 - Carbon dioxide and clean agent alarms.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Carbon dioxide and clean agent alarms. 131.815 Section 131.815 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.815 Carbon dioxide and clean agent alarms. Each carbon dioxide or clean agent fire...
77 FR 38275 - Notice of Intent To Grant Exclusive Patent License; Emerging Growth Enterprise LLC
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-27
..., nonassignable, exclusive license to practice in the field of fire fighting foam discharge and suppression... November 6, 2007) and entitled, ``Nofoam system for testing a foam delivery system on a vehicle'', No. 7,293,478 (Issued November 13, 2007) and entitled ``Method for testing a foam delivery system on a...
Ready, Fire, Aim: The College Campus Gun Fight
ERIC Educational Resources Information Center
Birnbaum, Robert
2013-01-01
The question of whether guns should be permitted on college and university campuses in the United States reflects the tension between two competing perspectives. America has both a robust gun culture and an equally robust (if less well known) gun-control culture. The gun culture is as American as apple pie: There may be as many as 300 million…
Carlos Abrego Aguilar; F. Javier Romera López; Regina de la Rosa Calancha; Domingo Villalba Indurria
2013-01-01
SEILAF is a system designed for training, simulation and research in the fight again forest fires in a 3D world of a great virtual realism. A consortium of technological centers CITIC and CATEC, enterprises such as INDRA and FASSA, and the University of Cordoba have taken part in the design. The simulation center is located in Aeropolis, near the airport of...
Research on environmental impact of water-based fire extinguishing agents
NASA Astrophysics Data System (ADS)
Wang, Shuai
2018-02-01
This paper offers current status of application of water-based fire extinguishing agents, the environmental and research considerations of the need for the study of toxicity research. This paper also offers systematic review of test methods of toxicity and environmental impact of water-based fire extinguishing agents currently available, illustrate the main requirements and relevant test methods, and offer some research findings for future research considerations. The paper also offers limitations of current study.
Characterization of a mine fire using atmospheric monitoring system sensor data.
Yuan, L; Thomas, R A; Zhou, L
2017-06-01
Atmospheric monitoring systems (AMS) have been widely used in underground coal mines in the United States for the detection of fire in the belt entry and the monitoring of other ventilation-related parameters such as airflow velocity and methane concentration in specific mine locations. In addition to an AMS being able to detect a mine fire, the AMS data have the potential to provide fire characteristic information such as fire growth - in terms of heat release rate - and exact fire location. Such information is critical in making decisions regarding fire-fighting strategies, underground personnel evacuation and optimal escape routes. In this study, a methodology was developed to calculate the fire heat release rate using AMS sensor data for carbon monoxide concentration, carbon dioxide concentration and airflow velocity based on the theory of heat and species transfer in ventilation airflow. Full-scale mine fire experiments were then conducted in the Pittsburgh Mining Research Division's Safety Research Coal Mine using an AMS with different fire sources. Sensor data collected from the experiments were used to calculate the heat release rates of the fires using this methodology. The calculated heat release rate was compared with the value determined from the mass loss rate of the combustible material using a digital load cell. The experimental results show that the heat release rate of a mine fire can be calculated using AMS sensor data with reasonable accuracy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nacht, S.
1999-08-01
The Mercury Fire Training Pit is a former fire training area located in Area 23 of the Nevada Test Site (NTS). The Mercury Fire Training Pit was used from approximately 1965 to the early 1990s to train fire-fighting personnel at the NTS, and encompasses an area approximately 107 meters (m) (350 feet [ft]) by 137 m (450 ft). The Mercury Fire Training Pit formerly included a bermed burn pit with four small burn tanks, four large above ground storage tanks an overturned bus, a telephone pole storage area, and areas for burning sheds, pallets, and cables. Closure activities will includemore » excavation of the impacted soil in the aboveground storage tank and burn pit areas to a depth of 1.5 m (5 ft), and excavation of the impacted surface soil downgradient of the former ASTs and burnpit areas to a depth of 0.3 m (1 ft). Excavated soil will be disposed in the Area 6 Hydrocarbon Landfill at the NTS.« less
Giguère, Denis; Marchand, Denis
2005-01-01
Injuries related to emergency vehicles represent 19% of compensated work accidents for fire fighters, 37% of which occur while stepping down from their vehicles. This study compared the impact forces, the use of upper limbs and the perception of danger of fire fighters as they step down from five different locations on fire trucks. The results show that stepping down from the crew cab facing the street produces impact forces averaging 3.2 times the subject's body weight, but is also perceived as the safest way to descend in one of the two groups of fire fighters that participated in the study. Stepping down from the same location, but facing the truck, produced significantly less impact force and a better distribution of the energy over time. This may be achieved through better control of the descending leg, ankle flexion, and the use of grab bars. A re-design of the access to emergency vehicles should take into account both the safety needs and reduction in biomechanical stress of fire fighters.
Autonomous UAV-Based Mapping of Large-Scale Urban Firefights
DOE Office of Scientific and Technical Information (OSTI.GOV)
Snarski, S; Scheibner, K F; Shaw, S
2006-03-09
This paper describes experimental results from a live-fire data collect designed to demonstrate the ability of IR and acoustic sensing systems to detect and map high-volume gunfire events from tactical UAVs. The data collect supports an exploratory study of the FightSight concept in which an autonomous UAV-based sensor exploitation and decision support capability is being proposed to provide dynamic situational awareness for large-scale battalion-level firefights in cluttered urban environments. FightSight integrates IR imagery, acoustic data, and 3D scene context data with prior time information in a multi-level, multi-step probabilistic-based fusion process to reliably locate and map the array of urbanmore » firing events and firepower movements and trends associated with the evolving urban battlefield situation. Described here are sensor results from live-fire experiments involving simultaneous firing of multiple sub/super-sonic weapons (2-AK47, 2-M16, 1 Beretta, 1 Mortar, 1 rocket) with high optical and acoustic clutter at ranges up to 400m. Sensor-shooter-target configurations and clutter were designed to simulate UAV sensing conditions for a high-intensity firefight in an urban environment. Sensor systems evaluated were an IR bullet tracking system by Lawrence Livermore National Laboratory (LLNL) and an acoustic gunshot detection system by Planning Systems, Inc. (PSI). The results demonstrate convincingly the ability for the LLNL and PSI sensor systems to accurately detect, separate, and localize multiple shooters and the associated shot directions during a high-intensity firefight (77 rounds in 5 sec) in a high acoustic and optical clutter environment with no false alarms. Preliminary fusion processing was also examined that demonstrated an ability to distinguish co-located shooters (shooter density), range to <0.5 m accuracy at 400m, and weapon type.« less
46 CFR 78.47-9 - Carbon dioxide and clean agent alarms.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 3 2013-10-01 2013-10-01 false Carbon dioxide and clean agent alarms. 78.47-9 Section 78.47-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 78.47-9 Carbon dioxide and clean agent alarms. Each carbon dioxide or clean agent fire...
46 CFR 78.47-9 - Carbon dioxide and clean agent alarms.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 3 2012-10-01 2012-10-01 false Carbon dioxide and clean agent alarms. 78.47-9 Section 78.47-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 78.47-9 Carbon dioxide and clean agent alarms. Each carbon dioxide or clean agent fire...
46 CFR 78.47-9 - Carbon dioxide and clean agent alarms.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 3 2014-10-01 2014-10-01 false Carbon dioxide and clean agent alarms. 78.47-9 Section 78.47-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 78.47-9 Carbon dioxide and clean agent alarms. Each carbon dioxide or clean agent fire...
NASA Technical Reports Server (NTRS)
1980-01-01
Avco has drawn upon its heat shield experience to develop a number of widely-accepted commercial fire protection materials. Originating from NASA's space shuttle thermal protection system, one such material is Chartek 59 fireproofing, an intumescent epoxy coating specifically designed for outdoor use by industrial facilities dealing with highly flammable products such as oil refineries and chemical plants. The coating is applied usually by spray gun to exterior structural steel conduits, pipes and valves, offshore platforms and liquefied petroleum gas tanks. Fireproofing provides two types of protection: ablation or dissipation of heat by burn-off and "intumescence" or swelling; the coating swells to about five times its original size, forming a protective blanket of char which retards transfer of heat to the metal structure preventing loss of structural strength and possible collapse which would compound the fire fighting problem.
NASA Astrophysics Data System (ADS)
Li-bo, Dang; Jia-chun, Wu; Yue-xing, Liu; Yuan, Chang; Bin, Peng
2017-04-01
Underground coal fire (UCF) is serious in Xinjiang region of China. In order to deal with this problem efficiently, a UCF monitoring System, which is based on the use of wireless communication technology and remote sensing images, was designed and implemented by Xinjiang Coal Fire Fighting Bureau. This system consists of three parts, i.e., the data collecting unit, the data processing unit and the data output unit. For the data collecting unit, temperature sensors and gas sensors were put together on the sites with depth of 1.5 meter from the surface of coal fire zone. Information on these sites' temperature and gas was transferred immediately to the data processing unit. The processing unit was developed by coding based on GIS software. Generally, the processed datum were saved in the computer by table format, which can be displayed on the screen as the curve. Remote sensing image for each coal fire was saved in this system as the background for each monitoring site. From the monitoring data, the changes of the coal fires were displayed directly. And it provides a solid basis for analyzing the status of coal combustion of coal fire, the gas emission and possible dominant direction of coal fire propagation, which is helpful for making-decision of coal fire extinction.
Fire Weather Products for Public and Emergency Use: Extending Professional Resources to the Public
NASA Astrophysics Data System (ADS)
Rogers, M. A.; Schranz, S.; Kriederman, L.
2012-12-01
Large wildfires require significant resources to combat, including dedicated meteorological support to provide accurate and timely forecasts to assist incident commanders in making decisions for logistical and tactical firefighting operations. Smaller fires often require the same capabilities for understanding fire and the fire weather environment, but access to needed resources and tools is often limited due to technical, training, or education limitations. Providing fire weather information and training to incident commanders for smaller wildfires should prove to enhance firefighting capabilities and improve safety for both firefighters and for the public as well. One of the premier tools used to support fire weather forecasting for the largest wildfires is the FX-Net product, a thin-client version of the Advanced Weather Interactive Processing System used by NWS incident meteorologists (IMETs) deployed to large wildfires. We present results from an ongoing project to extend the sophisticated products available from FX-Net to more accessible and mobile software platforms, such as Google Earth. The project involves input from IMETs and fire commanders to identify the key parameters used in fighting wildfires, and involves a large training component for fire responders to utilize simplified products to improve understanding of fire weather in the context of firefighting operations.
NASA Astrophysics Data System (ADS)
Lanorte, Antonio; Desantis, Fortunato; Aromando, Angelo; Lasaponara, Rosa
2013-04-01
This paper presents the results we obtained in the context of the FIRE-SAT project during the 2012 operative application of the satellite based tools for fire monitoring. FIRE_SAT project has been funded by the Civil Protection of the Basilicata Region in order to set up a low cost methodology for fire danger monitoring and fire effect estimation based on satellite Earth Observation techniques. To this aim, NASA Moderate Resolution Imaging Spectroradiometer (MODIS), ASTER, Landsat TM data were used. Novel data processing techniques have been developed by researchers of the ARGON Laboratory of the CNR-IMAA for the operative monitoring of fire. In this paper we only focus on the danger estimation model which has been fruitfully used since 2008 to 2012 as an reliable operative tool to support and optimize fire fighting strategies from the alert to the management of resources including fire attacks. The daily updating of fire danger is carried out using satellite MODIS images selected for their spectral capability and availability free of charge from NASA web site. This makes these data sets very suitable for an effective systematic (daily) and sustainable low-cost monitoring of large areas. The preoperative use of the integrated model, pointed out that the system properly monitor spatial and temporal variations of fire susceptibility and provide useful information of both fire severity and post fire regeneration capability.
Real-time photorealistic stereoscopic rendering of fire
NASA Astrophysics Data System (ADS)
Rose, Benjamin M.; McAllister, David F.
2007-02-01
We propose a method for real-time photorealistic stereo rendering of the natural phenomenon of fire. Applications include the use of virtual reality in fire fighting, military training, and entertainment. Rendering fire in real-time presents a challenge because of the transparency and non-static fluid-like behavior of fire. It is well known that, in general, methods that are effective for monoscopic rendering are not necessarily easily extended to stereo rendering because monoscopic methods often do not provide the depth information necessary to produce the parallax required for binocular disparity in stereoscopic rendering. We investigate the existing techniques used for monoscopic rendering of fire and discuss their suitability for extension to real-time stereo rendering. Methods include the use of precomputed textures, dynamic generation of textures, and rendering models resulting from the approximation of solutions of fluid dynamics equations through the use of ray-tracing algorithms. We have found that in order to attain real-time frame rates, our method based on billboarding is effective. Slicing is used to simulate depth. Texture mapping or 2D images are mapped onto polygons and alpha blending is used to treat transparency. We can use video recordings or prerendered high-quality images of fire as textures to attain photorealistic stereo.
Investigation of a novel image segmentation method dedicated to forest fire applications
NASA Astrophysics Data System (ADS)
Rudz, S.; Chetehouna, K.; Hafiane, A.; Laurent, H.; Séro-Guillaume, O.
2013-07-01
To face fire it is crucial to understand its behaviour in order to maximize fighting means. To achieve this task, the development of a metrological tool is necessary for estimating both geometrical and physical parameters involved in forest fire modelling. A key parameter is to estimate fire positions accurately. In this paper an image processing tool especially dedicated to an accurate extraction of fire from an image is presented. In this work, the clustering on several colour spaces is investigated and it appears that the blue chrominance Cb from the YCbCr colour space is the most appropriate. As a consequence, a new segmentation algorithm dedicated to forest fire applications has been built using first an optimized k-means clustering in the Cb-channel and then some properties of fire pixels in the RGB colour space. Next, the performance of the proposed method is evaluated using three supervised evaluation criteria and then compared to other existing segmentation algorithms in the literature. Finally a conclusion is drawn, assessing the good behaviour of the developed algorithm. This paper is dedicated to the memory of Dr Olivier Séro-Guillaume (1950-2013), CNRS Research Director.
Was Hawan Designed to Fight Anxiety-Scientific Evidences?
Romana, R K; Sharma, A; Gupta, V; Kaur, R; Kumar, S; Bansal, P
2017-01-06
Anxiety is a psychiatric disorder with unknown neurobiology; however, neurotransmitters like gamma-amino butyric acid, norepinephrine and serotonin (5-HT) play crucial roles in mediating anxiety. Present drug modules pose dependence risk to the patient; hence, there is a great need to develop complementary therapies to fight this disorder. Aromatherapy has also been employed in ancient times for a number of mental disorders. Mahamrituanjay Mantra, Om triambkum yajamahe, sughandhim puushtivardhanam, urvarukmev vandhanaat, mrityu mokshay mamritaat!!!!, the part of veda enlightens that aroma gives rise to good health (sughandhim puushtivardhanam). Hawan is a religious practice recommended for mental peace. Hawan is a process in which special herbs are offered in the fire of medicinal woods ignited in a specially designed fire pit. Analysis of literature demonstrates that the components of Hawan are having a number of volatile oils that are specifically useful for prevention and treatment of anxiety through some mechanism of action. Due to high temperature of fire, the vapors of these oils from herbs enter into the central nervous system through nasal route. As per modern science and ancient texts on medicine, nasal drug delivery systems are the best for the diseases related to brain and head. The routine of performing Hawan might keep the threshold value of the therapeutic components in the body and help in preventing anxiety. In the present manuscript, authors highlight and integrate the modern and ancient concepts for treatment and prevention of anxiety through scientific evidences.
Stronger Fire-Resistant Epoxies
NASA Technical Reports Server (NTRS)
Fohlen, George M.; Parker, John A.; Kumar, Devendra
1988-01-01
New curing agent improves mechanical properties and works at lower temperature. Use of aminophenoxycyclotriphosphazene curing agents yields stronger, more heat- and fire-resistant epoxy resins. Used with solvent if necessary for coating fabrics or casting films.
Emissions reduction from small-scale coal-fired sources in Poland
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gyorke, D.F.; Butcher, T.A.; Blinn, M.B.
1994-12-31
In an address to the Polish Parliament on July 10, 1989, President George Bush pledged that the United States would assist Poland, and the City of Krakow in particular, in the fight against pollution. Poland, as other countries of the former Soviet bloc, experienced severe pollution when production was favored over modernization of equipment and protection of the environment.
ERIC Educational Resources Information Center
Holmgren, Robert
2015-01-01
This article reports on findings from a comparative study on firefighter students' learning processes in a technology-supported distance training course and a traditional campus training course in Sweden. Based on student interviews and observations of exercises, the article aims to describe and analyse the impact on learning processes when…
Fighting Tomorrows Fire Today: Leveraging Intelligence for Scenario-Based Exercise Design
2014-03-01
Management and Budget, Paperwork Reduction Project (0704–0188) Washington, DC 20503. 1. AGENCY USE ONLY (Leave blank) 2. REPORT DATE March 2014 3...IPG Improvised Projected Grenade IT information technology LLIS Lessons Learned Information Sharing MEP Master Exercise Practitioner MOU...Disaster?” Natural Hazards 18, no. 1 (1998): 87–88. xvii THIS PAGE INTENTIONALLY LEFT BLANK xviii
Joint Tactics, Techniques, and Procedures for Foreign Humanitarian Assistance
2001-08-15
violence and nuclear, biological, or chemical (NBC) accidents). DOD policy permits military components to participate in FHA operations in response to...Acts of Man Flood, Drought, Fire, Hurricane, Earthquake Volcanic Eruption Civil Violence Nuclear, Biological, or Chemical Accidents FOREIGN DISASTERS I...Supply shortages developed, particularly of items not ordinarily required by a fighting unit — catheters for small children , for example. Finally
Qualification of an Acceptable Alternative to Halon 1211 DOD Flightline Extinguishers
2008-09-01
Minimum Performance Standard MSDS Material Safety Data Sheet NATO North Atlantic Treaty Organization NAWCAD Naval Air Warfare Center Aircraft...included chronic and acute occupational exposure limits and cardiotoxicity. Alternatives that were carcinogens or that had any adverse developmental...gear to fight the fires Does not exceed pain threshold for exposed skin Each unit tested met this performance objective 2. Firefighting
Fighting fire with education: what is the best way to reach out to homeowners?
Sarah M. McCaffrey
2004-01-01
Better understanding is needed of what makes educational efforts most effective in increasing public support for wildfire management and mitigation efforts. Results of a mail survey of homeowners in Incline Village, Nevada, indicate that personalized contact is key in the educational process and that which type of contact - government or personal - is more influential...
John R. Britt; Jason P. Reynolds
2013-01-01
In plantation forestry, several silvicultural treatments can be row oriented. When rows are treated individually, planting trees in wider rows may result in lower silvicultural treatment cost, facilitate future operations, such as thinning and fire fighting, and provide a longer period with open canopy conditions. All these scenarios could provide benefit to landowners...
Vulnerability Analysis of an All-Electric Warship
2010-06-01
active. Damage Control: Fire fighting, dewatering, lighting, electrical receptacles (for powering damage control equipment such as submersible pumps ...sufficient radar not available. This also requires an increase in chill water capacity by adding pump , compressor, and ASW pump . Remaining ventilation systems...Activate towed-array sonar, if applicable. Increase speed to 25 knots. Non-Vital Loads: All non-vital loads. Examples include galley equipment, heat
ERIC Educational Resources Information Center
Stephen, Dawn E.; O'Connell, Paul; Hall, Mike
2008-01-01
In highlighting a gulf between inclusive policy intentions inherent in the advent of mass higher education in the UK and the lived experiences of students and staff, this paper aims to stimulate critical debate about the impact of this changed environment upon traditional personal tutoring relationships. In drawing upon qualitative research with a…
Energy cost of the Trondheim firefighter test for experienced firefighters.
von Heimburg, Erna; Medbø, Jon Ingulf
2013-01-01
The aim of this study was to measure aerobic demands of fire fighting activities including exercise in the heat. Twenty-two experienced firefighters performed the Trondheim test simulating fire fighting tasks including work in the heat. Maximal oxygen uptake (VO2 max), heart rate (HR) and ventilation were recorded continuously. Data were compared with results obtained during a treadmill test during which the participants were dressed as smoke divers. The participants completed physical parts of the Trondheim test in ˜12 min (range: 7.5-17.4). Time to complete the test was closely related to the participant's VO2 max. HR of ˜170 beats/min and pulmonary ventilation of ˜100 L/min were higher than at lactate threshold (LT) during laboratory tests. VO2 averaged over the test's physical part was 35 ± 7 ml/min/kg, which was at the same or below the level corresponding to the participants' LT. Physically fit participants completed the test faster than less fit participants. Slower and physically less fit participants consumed more air and used more oxygen than faster and physically more fit participants. The Trondheim test is physically demanding; it distinguishes physically fit and less fit participants.
[Occupational risks among public safety and security forces].
Candura, S M; Verni, P; Minelli, C M; Rosso, G L; Cappelli, M I; Strambi, S; Martellosio, V
2006-01-01
The present paper tries to identify the occupational risk factors (physical, chemical, biological, psychological), variable depending on jobs and tasks, to which the heterogeneous public safety/security workers are exposed. The fight against criminality and public order maintenance imply (sometimes fatal) traumatic risks, and expose to psychophysical and sensorial tiring, unfavourable macro- and microclimatic conditions, the risk of baropathy (air navigation, underwater activities), noise (generated by firearms and several other sources), vibrations and shakings (automatic weapons, transport vehicles), the risk of electric injury, ionizing (X and gamma rays) and non-inonizing (ultraviolet rays, microwaves and radiofrequencies, electromagnetic fields) radiations. Chemical hazards include carbon monoxide and other combustion products (fires, urban traffic), substances released in chemical accidents, tear gases, lead (firing grounds, metal works, environmental pollution), solvents, lubrificants and cutting oils (mechanic repair and maintenance), laboratory materials and reagents, irritant and/or sensitizing agents contained in gloves. The main biological risks are tetanus, blood-borne diseases (viral hepatitis, AIDS), aerogenous diseases (e.g., tuberculosis, Legionnaire's disease, epidemic cerebrospinal meningitis), dog- or horse-transmitted zoonosis. Finally, emotional, psychosomatic and behavioural stress-related disorders (e.g., burn-out syndrome, post-traumatic stress disorder) are typically frequent. The presence of numerous and diversified hazards among public safety/security forces imposes the adoption of occupational medicine measures, including risk assessment, health education, technical and environmental prevention, personal protective devices, sanitary surveillance and biological monitoring, clinical interventions (diagnosis, therapy and rehabilitation of occupational accidents and illnesses), prompt medico-legal evaluation of occupational-related compensation claims.
Fire Control Agent Effectiveness for Hazardous Chemical Fires: Carbon Disulfide.
1981-01-01
Fires..................................... 46 12. AFFF Fire Control Data for Carbon Disulfide Fires............................. 47 13. Extinguishment...Disulfide and Hexane Fires ....... 67 22. Comparison of AFFF Fire Control Times for Carbon Disulfide and Hexane Fires ................... 68 23. Comparison of...Data .............. 27 2. Summary of Fluoroprotein Foam Fire Test Data ....... 28 3. Summary of AFFF Fire Test Data ..................... 29 4. Summary
2004-06-09
KENNEDY SPACE CENTER, FLA. - At Cape Canaveral Air Force Station, Firefighter Chris Maupin (left) and Lt. Keith Abell demonstrate how the special aircraft firefighting vehicle (known as ARF) was used at the site of a recent fire in Brevard County, Fla. The firefighters sit inside the vehicle with a "driver" in the middle. They are able to direct the hoses to attack fires from above and below. The firefighters teamed up with task forces from Satellite Beach, Malabar, Melbourne, Palm Bay, Patrick Air Force Base and Brevard County to help fight wildfires in the Palm Bay and Malabar areas that threatened homes and property during the Memorial Day holiday weekend.
Fighting fire with fire: physicians blazing new paths to autonomy.
Vavala, D
1995-04-01
Thousands of physicians around the country have stopped complaining about being burned by the system and have started reengineering their destinies. They're building super IPAs, forming and operating HMOs, and joining unions to represent their rights in a growing grassroots physician effort to regain control. These physicians have thumbed their noses at managed care companies they say have drastically cut reimbursements, arbitrarily dropped them from panels, dictated utilization, and cost them patients. They're tired of working harder and earning less and frustrated by sacrificing quality in the name of cost reduction. And they have learned that there are ways to prevail.
Fighting Fire with Fire: Surgical Options for Patients with Drug-Resistant Epilepsy.
Bayer, Alina D; Blum, Andrew S; Asaad, Wael F; Roth, Julie; Toms, Steven A; Deck, Gina M
2018-03-01
While antiepileptic drugs (AEDs) provide adequate seizure control for most patients with epilepsy, ~30% continue to have seizures despite treatment with two or more AEDs.1 In addition to direct harm from seizures, poor epilepsy control correlates with higher mortality, morbidity, 2, 3 and cost to the healthcare system.4 In the subset of patients with persistent seizures despite medical management, surgical intervention and neuromodulation may be more effective. Primary care physicians and general neurologists should be aware of non-AED treatment options that are standard of care for drug- resistant epilepsy (DRE). [Full article available at http://rimed.org/rimedicaljournal-2018-03.asp].
NASA Astrophysics Data System (ADS)
Rivai, M.; Hambali, E.; Suryani, A.; Fitria, R.; Firmansyah, S.; Pramuhadi, G.
2018-03-01
The utilization of foaming agent for fire extinguisher application improves the efficiency of water as a fire extinguishing agent, lowers surface tension, and acts as a foaming agent. The formed foam cools the fire down and covers the burned material to avoid it from further contact with oxygen which may reignite the fire. This study aimed to produce and assess the performance of foaming agent concentrate from palm oil as a fire extinguisher agent. In the performance test, measurements were taken on foam stability, foaming ability, surface tension, interfacial tension, viscosity, contact angle, density, and specific gravity. The formulation was conducted by using the best produced potassium palmitate, potassium methyl ester, and sodium lauric combined with diluents, chelating agent, and other additives at various composition comparisons. The produced foaming agent concentrate was found to be in a rather paste and liquid form with viscosity of 2.34 – 253 cP. It was also found that the resulted foaming agent concentrate dissolved in water at the concentration rate of 1% had a foam stability level of 30-91%, foaming ability of 288 – 503%, surface tension of 19.68 – 25.05 dyne/cm, interfacial tension of 0.54 – 4,20 dyne/cm, viscosity of 1.00 – 1.05 cP, contact angles of 53.75 – 63.79° at 0 minute and 11.84 – 22.42 ° at minute 10, density of 0.99586 – 0.99612 g/cm3, and a specific gravity of 1.00021 – 1.00046. Based on foam stability, foaming ability, and surface tension parameters, it was concluded that NF5 and NF17 were the best formulas.Compared to the other formulas, NF5 formula had the best droplet diameter (minimum 0.14 mm) and droplet density (maximum 3056 droplets/cm2).
Sensor data monitoring and decision level fusion scheme for early fire detection
NASA Astrophysics Data System (ADS)
Rizogiannis, Constantinos; Thanos, Konstantinos Georgios; Astyakopoulos, Alkiviadis; Kyriazanos, Dimitris M.; Thomopoulos, Stelios C. A.
2017-05-01
The aim of this paper is to present the sensor monitoring and decision level fusion scheme for early fire detection which has been developed in the context of the AF3 Advanced Forest Fire Fighting European FP7 research project, adopted specifically in the OCULUS-Fire control and command system and tested during a firefighting field test in Greece with prescribed real fire, generating early-warning detection alerts and notifications. For this purpose and in order to improve the reliability of the fire detection system, a two-level fusion scheme is developed exploiting a variety of observation solutions from air e.g. UAV infrared cameras, ground e.g. meteorological and atmospheric sensors and ancillary sources e.g. public information channels, citizens smartphone applications and social media. In the first level, a change point detection technique is applied to detect changes in the mean value of each measured parameter by the ground sensors such as temperature, humidity and CO2 and then the Rate-of-Rise of each changed parameter is calculated. In the second level the fire event Basic Probability Assignment (BPA) function is determined for each ground sensor using Fuzzy-logic theory and then the corresponding mass values are combined in a decision level fusion process using Evidential Reasoning theory to estimate the final fire event probability.
NASA Astrophysics Data System (ADS)
Shah-Heydari pour, A.; Pahlavani, P.; Bigdeli, B.
2017-09-01
According to the industrialization of cities and the apparent increase in pollutants and greenhouse gases, the importance of forests as the natural lungs of the earth is felt more than ever to clean these pollutants. Annually, a large part of the forests is destroyed due to the lack of timely action during the fire. Knowledge about areas with a high-risk of fire and equipping these areas by constructing access routes and allocating the fire-fighting equipment can help to eliminate the destruction of the forest. In this research, the fire risk of region was forecasted and the risk map of that was provided using MODIS images by applying geographically weighted regression model with Gaussian kernel and ordinary least squares over the effective parameters in forest fire including distance from residential areas, distance from the river, distance from the road, height, slope, aspect, soil type, land use, average temperature, wind speed, and rainfall. After the evaluation, it was found that the geographically weighted regression model with Gaussian kernel forecasted 93.4% of the all fire points properly, however the ordinary least squares method could forecast properly only 66% of the fire points.
Code of Federal Regulations, 2012 CFR
2012-07-01
... latest edition of the NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems, for whichever... requirements. 4—The agent should be recovered from the fire protection system in conjunction with testing or... coverage related to the use of personal protective equipment (e.g., respiratory protection), fire...
Code of Federal Regulations, 2013 CFR
2013-07-01
... latest edition of the NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems, for whichever... requirements. 4—The agent should be recovered from the fire protection system in conjunction with testing or... coverage related to the use of personal protective equipment (e.g., respiratory protection), fire...
Code of Federal Regulations, 2014 CFR
2014-07-01
... latest edition of the NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems, for whichever... requirements. 4—The agent should be recovered from the fire protection system in conjunction with testing or... coverage related to the use of personal protective equipment (e.g., respiratory protection), fire...
Akay, Abdullah E; Wing, Michael G; Sivrikaya, Fatih; Sakar, Dursun
2012-03-01
The ability of firefighting vehicles and staff to reach a fire area as quickly as possible is critical in fighting against forest fires. In this study, a Geographical Information System-based decision support system was developed to assist fire managers in determining the fastest and the safest or more reliable access routes from firefighting headquarters to fire areas. The decision support system was tested in the Kahramanmaras Forestry Regional Directoratein the Mediterranean region of Turkey. The study area consisted of forested lands which had been classified according to fire sensitivity. The fire response routing simulations considered firefighting teams located in 20 firefighting headquarter locations. The road network, the locations of the firefighting headquarters, and possible fire locations were mapped for simulation analysis. In alternative application simulations, inaccessible roads which might be closed due to fire or other reasons were indicated in the network analysis so that the optimum route was not only the fastest but also the safest and most reliable path. The selection of which firefighting headquarters to use was evaluated by considering critical response time to potential fire areas based on fire sensitivity levels. Results indicated that new firefighting headquarters should be established in the region in order to provide sufficient firefighting response to all forested lands. In addition, building new fire access roads and increasing the design speed on current roads could also increase firefighting response capabilities within the study area.
Characterization of a mine fire using atmospheric monitoring system sensor data
Yuan, L.; Thomas, R.A.; Zhou, L.
2017-01-01
Atmospheric monitoring systems (AMS) have been widely used in underground coal mines in the United States for the detection of fire in the belt entry and the monitoring of other ventilation-related parameters such as airflow velocity and methane concentration in specific mine locations. In addition to an AMS being able to detect a mine fire, the AMS data have the potential to provide fire characteristic information such as fire growth — in terms of heat release rate — and exact fire location. Such information is critical in making decisions regarding fire-fighting strategies, underground personnel evacuation and optimal escape routes. In this study, a methodology was developed to calculate the fire heat release rate using AMS sensor data for carbon monoxide concentration, carbon dioxide concentration and airflow velocity based on the theory of heat and species transfer in ventilation airflow. Full-scale mine fire experiments were then conducted in the Pittsburgh Mining Research Division’s Safety Research Coal Mine using an AMS with different fire sources. Sensor data collected from the experiments were used to calculate the heat release rates of the fires using this methodology. The calculated heat release rate was compared with the value determined from the mass loss rate of the combustible material using a digital load cell. The experimental results show that the heat release rate of a mine fire can be calculated using AMS sensor data with reasonable accuracy. PMID:28845058
Active fire detection using a peat fire radiance model
NASA Astrophysics Data System (ADS)
Kushida, K.; Honma, T.; Kaku, K.; Fukuda, M.
2011-12-01
The fire fractional area and radiances at 4 and 11 μm of active fires in Indonesia were estimated using Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) images. Based on these fire information, a stochastic fire model was used for evaluating two fire detection algorithms of Moderate Resolution Imaging Spectroradiometer (MODIS). One is single-image stochastic fire detection, and the other is multitemporal stochastic fire detection (Kushida, 2010 - IEEE Geosci. Remote Sens. Lett.). The average fire fractional area per one 1 km2 ×1 km2 pixel was 1.7%; this value corresponds to 32% of that of Siberian and Mongolian boreal forest fires. The average radiances at 4 and 11 μm of active fires were 7.2 W/(m2.sr.μm) and 11.1 W/(m2.sr.μm); these values correspond to 47% and 91% of those of Siberian and Mongolian boreal forest fires, respectively. In order to get false alarms less than 20 points per 106 km2 area, for the Siberian and Mongolian boreal forest fires, omission errors (OE) of 50-60% and about 40% were expected for the detections by using the single and multitemporal images, respectively. For Indonesian peat fires, OE of 80-90% was expected for the detections by using the single images. For the peat-fire detections by using the multitemporal images, OE of about 40% was expected, provided that the background radiances were estimated from past multitemporal images with less than the standard deviation of 1K. The analyses indicated that it was difficult to obtain sufficient active-fire information of Indonesian peat fires from single MODIS images for the fire fighting, and that the use of the multitemporal images was important.
46 CFR 12.602 - Basic training.
Code of Federal Regulations, 2014 CFR
2014-10-01
...) Swimming while wearing a lifejacket. (v) Keeping afloat without a lifejacket. (2) Fire prevention and... extinguishers. (ii) Extinguishing smaller fires. e.g., electrical fires, oil fires, and propane fires. (iii... firefighting agent in an accommodation room or simulated engine room with fire and heavy smoke. (vii...
Research field of fire technology in Finland
NASA Astrophysics Data System (ADS)
Loikkanen, P.; Holm, C.
1987-02-01
The goal of the study is to give an overview of the whole diversified research field of fire technology and its problems. For this reason the research subjects have been grouped so that the responsibilities of different authorities, the legislation and specifications, various fields of technology, areas of industry, and groups of products could all be found as clearly as possible. The field has been divided into nine sub-areas. They are: general grounds, fire physics and chemistry, structural fire prevention, textiles and furnishings, devices for heating and other use, detection, fire fighting and rescue, quality control, and special problems. The sub-areas have been divided into 34 main subjects and these, excluding those of special problems, further into as many as 117 subject groups. Characteristics and problems of the sub-areas and the main subjects have been described. The subject groups have been characterized by key words and concepts which outline the projects. No concrete research projects and programs have, however, been directly suggested because their extent and contents depend essentially on financing and other available resources.
The Airman and the State: An F-22 Pilot’s Perspective on Civil-Military Relations
2010-02-18
often than not. President Truman fired General MacArthur for continuing 22 Ibid. 23 Russell F...theory, oversight mechanisms can include contract incentives, screening and selection, fire alarms, institutional checks, police patrols, and revising...right sort of agent enters into the contractual relationship. Fire alarms Use of outsiders to watch the agent and report on key outputs
78 FR 58967 - Airworthiness Directives; ATR-GIE Avions de Transport Régional Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-25
... extinction and allow fire propagation out of the nacelle fire protected area, resulting in damage to the... efficiency, delay the fire extinction and allow fire propagation out of the nacelle fire protected area... the decrease of the fire extinguishing agent efficiency, which could delay fire extinction and allow...
Acute toxicity of fire-retardant and foam-suppressant chemicals to yalella azteca (Saussure)
McDonald, Susan F.; Hamilton, Steven J.; Buhl, Kevin J.; Heisinger, James F.
1997-01-01
Acute toxicity tests were conducted with Hyalella azteca Saussure (an amphipod) exposed in soft and hard waters to three fire retardants (Fire-Trol GTS-R, Fire-Trol LCG-R, and Phos-Chek D75-F) and two foam suppressants (Phos-Chek WD-881 and Silv-Ex). The chemicals were slightly to moderately toxic to amphipods. The most toxic chemical to amphipods in soft and hard water was Phos-Chek WD-881 (96-h mean lethal concentration [LC50] equal to 10 mg/L and 22 mg/L, respectively), and the least toxic chemical to amphipods in soft water was Fire-Trol GTS-R (96-h LC50 equal to 127 mg/L) and in hard water was Fire-Trol LCG-R (96-h LC50 equal to 535 mg/L). Concentrations of ammonia in tests with the three fire retardants and both water types were greater than reported LC50 values and probably were the major toxic component. Estimated un-ionized ammonia concentrations near the LC50 were frequently less than the reported LC50 ammonia concentrations for amphipods. The three fire retardants were more toxic in soft water than in hard water even though ammonia and un-ionized ammonia concentrations were higher in hard water tests than in soft water tests. The accidental entry of fire-fighting chemicals into aquatic environments could adversely affect aquatic invertebrates, thereby disrupting ecosystem function.
Autonomous Underwater Vehicle Architecture Synthesis for Shipwreck Interior Exploration
2015-12-01
silt-out, strong and unpredictable currents, abrasion puncture and shock damage, temperature and pressure variations, toxic substances, corrosion...smooth to resist snagging on debris, and sufficiently lightweight to be portable by two men. 2. The vehicle shall be capable of autonomous...1989, the Komsomolets (K-278), a Russian nuclear attack submarine operating in the Norwegian Sea, went down after unsuccessfully fighting a fire in
Responding to Hate and Bias at School. A Guide for Administrators, Counselors and Teachers
ERIC Educational Resources Information Center
Willoughby, Brian
2012-01-01
Your school has plans and protocols in place to respond to fires, severe weather, medical emergencies, fights and weapons possession. But what about school incidents like those listed above that involve bigotry and hate? Are plans in place to respond to a bias incident or hate crime? Too often these plans are created in the moment during the…
Air Cushion Crash Rescue Vehicle (ACCRV)
1987-10-01
capability to operate over rough and low strength ground surfaces, especially soft, wet ground or marsh and snow, with no capability for overwater...operation. In a wartime environment , fire fighting and res- cue will be further restricted because of craters, debris or unexploded bombs. Improved...swamps and, of course, in more conventional environments on or about airports. The integration of an air cushion system with a paddle track propulsor
2004-06-09
KENNEDY SPACE CENTER, FLA. - At Cape Canaveral Air Force Station, Lt. Keith Abell (left) and KSC Firefighter Chris Maupin store equipment on the fire truck. They and other KSC firefighters teamed up with task forces from Satellite Beach, Malabar, Melbourne, Palm Bay, Patrick Air Force Base and Brevard County to help fight wildfires in the Palm Bay and Malabar areas that threatened homes and property during the Memorial Day holiday weekend.
ERIC Educational Resources Information Center
May, Matthew S.
2011-01-01
From 1909 to 1910, the public performance of soap-box oratory began to effect dramatic changes in the composition of migrant workers throughout the Pacific Northwest. Municipal authorities in Spokane attempted to curb the formation of a union of hobo orators by outlawing public speech-making within the city fire limits. The ensuing confrontation…
Mammalian Toxicology Testing: Problem Definition Study, Global Army Toxicology Requirements.
1981-03-01
Electronic Warfare Equipment (D251) Tactical ECK System (64750A) Protective Electronic Warfare Equipment (D540) High Energy Electromagnetic Radiation...Fighting Portable Weapon (for IFV) Smoke Grenade Launcher Staff Smart, Target-Activated Fire-and-Forget Tactical ECK System (63755A) Protective Electronic...Warfare Equipment (D251) Tactical ECK System (64750A) Protective Electronic Warfare Equipment (D540) High Energy Electromagnetic Radiation Weapons (e.g
Schöllnberger, H; Aden, J; Scott, B R
2002-01-01
Forest-fire smoke inhaled by humans can cause various health effects. This smoke contains toxic chemicals and naturally occurring radionuclides. In northern New Mexico, a large wildfire occurred in May 2000. Known as the Cerro Grande Fire, it devastated the town of Los Alamos and damaged Los Alamos National Laboratory (LANL). Residents were concerned about the possible dissemination of radionuclides from LANL via smoke from the fire. To evaluate potential health effects of inhaling radionuclides contained in the smoke from the Cerro Grande Fire, it was first necessary to evaluate how much smoke would deposit in the human respiratory tract. The purpose of this study was to evaluate respiratory-tract deposition efficiencies of airborne forest-fire smoke for persons of different ages exposed while inside their homes. Potential non-radiological health effects of a forest fire are reviewed. The deposition efficiencies presented can be used to evaluate in-home smoke deposition in the respiratory tract and expected radionuclide intake related to forest fires. The impact of smoke exposure on firemen fighting a forest fire is quantitatively discussed and compared. They primarily inhaled forest-fire smoke while outdoors where the smoke concentration was much higher than inside. Radionuclides released at the LANL site via the Cerro Grande Fire were restricted to naturally occurring radionuclides from burning trees and vegetation. Radiation doses from inhaled airborne radionuclides to individuals inside and outside the Los Alamos area were likely very small.
Environmental influences on risk taking among Hong Kong young dance partygoers.
Ngai, Steven Sek-Yum; Ngai, Ngan-pun; Cheung, Chau-kiu
2006-01-01
This study investigates risk-taking behavior and its associated factors among young Hong Kong partygoers at rave parties or discos. Based on a survey of 300 14 to 28-year-old dance partygoers recruited by outreaching social workers, the study provides data on risks in terms of the likelihood of drug abuse, coitus, unprotected coitus, fighting, and high-speed driving among the young people. Furthermore, it examines factors related to the dance party, together with a set of background factors on the partygoer's report of the chance of engaging in risky behavior as expected in the coming six months. Factors related to the dance party include the location (Hong Kong and Mainland China), fees, number of partners, dancers, police inspection, drug supply, drug sales, injuries, coitus, fighting, drug abuse, and environmental factors. The environmental factors are the availability of first aid, fire extinguishing, and drinking water facilities, light and audio effects, ventilation, drug circulation, underage admission, sex partners, fighting, and low-price beer. Implications of present findings for social policy and future research are discussed.
Partially Premixed Flame (PPF) Research for Fire Safety
NASA Technical Reports Server (NTRS)
Puri, Ishwar K.; Aggarwal, Suresh K.; Lock, Andrew J.; Hegde, Uday
2004-01-01
Incipient fires typically occur after the partial premixing of fuel and oxidizer. The mixing of product species into the fuel/oxidizer mixture influences flame stabilization and fire spread. Therefore, it is important to characterize the impact of different levels of fuel/oxidizer/product mixing on flame stabilization, liftoff and extinguishment under different gravity conditions. With regard to fire protection, the agent concentration required to achieve flame suppression is an important consideration. The initial stage of an unwanted fire in a microgravity environment will depend on the level of partial premixing and the local conditions such as air currents generated by the fire itself and any forced ventilation (that influence agent and product mixing into the fire). The motivation of our investigation is to characterize these impacts in a systematic and fundamental manner.
Smouldering Fires in the Earth System
NASA Astrophysics Data System (ADS)
Rein, G.
2012-04-01
Smouldering fires, the slow, low-temperature, flameless burning, represent the most persistent type of combustion phenomena and the longest continuously fires on Earth system. Indeed, smouldering mega-fires of peatlands occur with some frequency during the dry session in, for example, Indonesia, Canada, Russia, UK and USA. Smouldering fires propagate slowly through organic layers of the ground and can reach depth >5 m if large cracks, natural piping or channel systems exist. It threatens to release sequestered carbon deep into the soil. Once ignited, they are particularly difficult to extinguish despite extensive rains, weather changes or fire-fighting attempts, and can persist for long periods of time (months, years) spreading deep and over extensive areas. Recent figures at the global scale estimate that average annual greenhouse gas emissions from smouldering fires are equivalent to 15% of man-made emissions. These fires are difficult or impossible to detect with current remote sensing methods because the chemistry is significantly different, their thermal radiation signature is much smaller, and the plume is much less buoyant. These wildfires burn fossil fuels and thus are a carbon-positive fire phenomena. This creates feedbacks in the climate system because soil moisture deficit and self-heating are enchanted under warmer climate scenarios and lead to more frequent fires. Warmer temperatures at high latitudes are resulting in more frequent Artic fires. Unprecedented permafrost thaw is leaving large soil carbon pools exposed to smouldering fires for the fist time since millennia. Although interactions between flaming fires and the Earth system have been a central focus, smouldering fires are as important but have received very little attention. DBut differences with flaming fires are important. This paper reviews the current knowledge on smouldering fires in the Earth system regarding combustion dynamics, damage to the soil, emissions, remote sensing and feedbacks in the climate system.
McCarley, T. Ryan; Kolden, Crystal A.; Vaillant, Nicole M.; Hudak, Andrew T.; Smith, Alistair M.S.; Kreitler, Jason R.
2017-01-01
Across the western United States, the three primary drivers of tree mortality and carbon balance are bark beetles, timber harvest, and wildfire. While these agents of forest change frequently overlap, uncertainty remains regarding their interactions and influence on specific subsequent fire effects such as change in canopy cover. Acquisition of pre- and post-fire Light Detection and Ranging (LiDAR) data on the 2012 Pole Creek Fire in central Oregon provided an opportunity to isolate and quantify fire effects coincident with specific agents of change. This study characterizes the influence of pre-fire mountain pine beetle (MPB; Dendroctonus ponderosae) and timber harvest disturbances on LiDAR-estimated change in canopy cover. Observed canopy loss from fire was greater (higher severity) in areas experiencing pre-fire MPB (Δ 18.8%CC) than fire-only (Δ 11.1%CC). Additionally, increasing MPB intensity was directly related to greater canopy loss. Canopy loss was lower for all areas of pre-fire timber harvest (Δ 3.9%CC) than for fire-only, but among harvested areas, the greatest change was observed in the oldest treatments and the most intensive treatments [i.e., stand clearcut (Δ 5.0%CC) and combination of shelterwood establishment cuts and shelterwood removal cuts (Δ 7.7%CC)]. These results highlight the importance of accounting for and understanding the impact of pre-fire agents of change such as MPB and timber harvest on subsequent fire effects in land management planning. This work also demonstrates the utility of multi-temporal LiDAR as a tool for quantifying these landscape-scale interactions.
Initial Evaluation of Burn Characteristics of Phenolic Foam Runway Brake Arrestor Material
1993-12-01
foam immersed in a jet fuel fire when extinguished using 3-percent Aqueous Film Forming Foam ( AFFF ). Three pool...extinguishment time of phenolic foam immersed in a jet fuel fire, using 3-percent Aqueous Film Forming Foam ( AFFF ) extinguishing agent. The wind was negligible...percent Aqueous Film Forming Foam ( AFFF ) agent. This project is an initial assessment of the fire safety of phenolic foam
The use of fire in forest restoration
Colin C. Hardy; Stephen F. Arno
1996-01-01
The 26 papers in this document address the current knowledge of fire as a disturbance agent, fire history and fire regimes, applications of prescribed fire for ecological restoration, and the effects of fire on the various forested ecosystems of the north-western United States. The main body of this document is organized in three sections: Assessing Needs for Fire in...
Devastation from California's Largest Wildfire Seen in New NASA Satellite Image
2018-01-05
The Thomas Fire is the largest wildfire in California's recorded history. As of January 3, 2018, it was 93 percent contained after burning 282,000 acres and destroying 1,063 structures. The fire started Dec. 4, 2017, and quickly spread out of control, fanned by high temperatures and winds. At its peak, more than 8,500 firefighters mobilized to fight it. The Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) instrument on NASA's Terra satellite acquired this image on Dec. 26, 2017. It covers an area of 21 by 38 miles (33 by 61.8 kilometers), and is located at 34.5 degrees north, 119.3 degrees west. https://photojournal.jpl.nasa.gov/catalog/PIA22189
Fire Suppression in Low Gravity Using a Cup Burner
NASA Technical Reports Server (NTRS)
Takahashi, Fumiaki; Linteris, Gregory T.; Katta, Viswanath R.
2004-01-01
Longer duration missions to the moon, to Mars, and on the International Space Station increase the likelihood of accidental fires. The goal of the present investigation is to: (1) understand the physical and chemical processes of fire suppression in various gravity and O2 levels simulating spacecraft, Mars, and moon missions; (2) provide rigorous testing of numerical models, which include detailed combustion suppression chemistry and radiation sub-models; and (3) provide basic research results useful for advances in space fire safety technology, including new fire-extinguishing agents and approaches. The structure and extinguishment of enclosed, laminar, methane-air co-flow diffusion flames formed on a cup burner have been studied experimentally and numerically using various fire-extinguishing agents (CO2, N2, He, Ar, CF3H, and Fe(CO)5). The experiments involve both 1g laboratory testing and low-g testing (in drop towers and the KC-135 aircraft). The computation uses a direct numerical simulation with detailed chemistry and radiative heat-loss models. An agent was introduced into a low-speed coflowing oxidizing stream until extinguishment occurred under a fixed minimal fuel velocity, and thus, the extinguishing agent concentrations were determined. The extinguishment of cup-burner flames, which resemble real fires, occurred via a blowoff process (in which the flame base drifted downstream) rather than the global extinction phenomenon typical of counterflow diffusion flames. The computation revealed that the peak reactivity spot (the reaction kernel) formed in the flame base was responsible for attachment and blowoff of the trailing diffusion flame. Furthermore, the buoyancy-induced flame flickering in 1g and thermal and transport properties of the agents affected the flame extinguishment limits.
Fire Suppression in Low Gravity Using a Cup Burner
NASA Technical Reports Server (NTRS)
Takahashi, Fumiaki; Linteris, Gregory T.; Katta, Viswanath R.
2004-01-01
Longer duration missions to the moon, to Mars, and on the International Space Station increase the likelihood of accidental fires. The goal of the present investigation is to: (1) understand the physical and chemical processes of fire suppression in various gravity and O2 levels simulating spacecraft, Mars, and moon missions; (2) provide rigorous testing of numerical models, which include detailed combustion-suppression chemistry and radiation sub-models; and (3) provide basic research results useful for advances in space fire safety technology, including new fire-extinguishing agents and approaches.The structure and extinguishment of enclosed, laminar, methane-air co-flow diffusion flames formed on a cup burner have been studied experimentally and numerically using various fire-extinguishing agents (CO2, N2, He, Ar, CF3H, and Fe(CO)5). The experiments involve both 1g laboratory testing and low-g testing (in drop towers and the KC-135 aircraft). The computation uses a direct numerical simulation with detailed chemistry and radiative heat-loss models. An agent was introduced into a low-speed coflowing oxidizing stream until extinguishment occurred under a fixed minimal fuel velocity, and thus, the extinguishing agent concentrations were determined. The extinguishment of cup-burner flames, which resemble real fires, occurred via a blowoff process (in which the flame base drifted downstream) rather than the global extinction phenomenon typical of counterflow diffusion flames. The computation revealed that the peak reactivity spot (the reaction kernel) formed in the flame base was responsible for attachment and blowoff of the trailing diffusion flame. Furthermore, the buoyancy-induced flame flickering in 1g and thermal and transport properties of the agents affected the flame extinguishment limits.
Fire Extinguisher Robot Using Ultrasonic Camera and Wi-Fi Network Controlled with Android Smartphone
NASA Astrophysics Data System (ADS)
Siregar, B.; Purba, H. A.; Efendi, S.; Fahmi, F.
2017-03-01
Fire disasters can occur anytime and result in high losses. It is often that fire fighters cannot access the source of fire due to the damage of building and very high temperature, or even due to the presence of explosive materials. With such constraints and high risk in the handling of the fire, a technological breakthrough that can help fighting the fire is necessary. Our paper proposed the use of robots to extinguish the fire that can be controlled from a specified distance in order to reduce the risk. A fire extinguisher robot was assembled with the intention to extinguish the fire by using a water pump as actuators. The robot movement was controlled using Android smartphones via Wi-fi networks utilizing Wi-fi module contained in the robot. User commands were sent to the microcontroller on the robot and then translated into robotic movement. We used ATMega8 as main microcontroller in the robot. The robot was equipped with cameras and ultrasonic sensors. The camera played role in giving feedback to user and in finding the source of fire. Ultrasonic sensors were used to avoid collisions during movement. Feedback provided by camera on the robot displayed on a screen of smartphone. In lab, testing environment the robot can move following the user command such as turn right, turn left, forward and backward. The ultrasonic sensors worked well that the robot can be stopped at a distance of less than 15 cm. In the fire test, the robot can perform the task properly to extinguish the fire.
A multimodal 3D framework for fire characteristics estimation
NASA Astrophysics Data System (ADS)
Toulouse, T.; Rossi, L.; Akhloufi, M. A.; Pieri, A.; Maldague, X.
2018-02-01
In the last decade we have witnessed an increasing interest in using computer vision and image processing in forest fire research. Image processing techniques have been successfully used in different fire analysis areas such as early detection, monitoring, modeling and fire front characteristics estimation. While the majority of the work deals with the use of 2D visible spectrum images, recent work has introduced the use of 3D vision in this field. This work proposes a new multimodal vision framework permitting the extraction of the three-dimensional geometrical characteristics of fires captured by multiple 3D vision systems. The 3D system is a multispectral stereo system operating in both the visible and near-infrared (NIR) spectral bands. The framework supports the use of multiple stereo pairs positioned so as to capture complementary views of the fire front during its propagation. Multimodal registration is conducted using the captured views in order to build a complete 3D model of the fire front. The registration process is achieved using multisensory fusion based on visual data (2D and NIR images), GPS positions and IMU inertial data. Experiments were conducted outdoors in order to show the performance of the proposed framework. The obtained results are promising and show the potential of using the proposed framework in operational scenarios for wildland fire research and as a decision management system in fighting.
Young fire ant workers feign death and survive aggressive neighbors
NASA Astrophysics Data System (ADS)
Cassill, Deby L.; Vo, Kim; Becker, Brandie
2008-07-01
Feigning death is a method of self-defense employed among a wide range of prey species when threatened by predator species. This paper reports on death-feigning behavior by the fire ant, Solenopsis invicta, during intraspecific aggression among neighboring fire ant workers. Days-old workers responded to aggression by death feigning, weeks-old workers responded by fleeing and months-old workers responded by fighting back. By feigning death, days-old workers were four times more likely to survive aggression than older workers. From a proximate perspective, retaliation by young workers against aggressive older workers is certain to fail. With their relatively soft exoskeleton, young workers would be prone to injury and death and unable to execute an effective attack of biting or stinging older workers with harder exoskeletons. From an ultimate perspective, death feigning allows young workers to survive and contribute to brood care and colony growth, both of which are essential to queen survival and fitness.
Characteristics and measurement of supersonic projectile shock waves by a 32-microphone ring array
NASA Astrophysics Data System (ADS)
Chang, Ho; Wu, Yan-Chyuan; Tsung, Tsing-Tshih
2011-08-01
This paper discusses about the characteristics of supersonic projectile shock wave in muzzle region during firing of high explosive anti-tank (HEAT) and high explosive (HE) projectiles. HEAT projectiles are fired horizontally at a muzzle velocity of Mach 3.5 from a medium caliber tank gun equipped with a newly designed multi-perforated muzzle brake, whereas HE projectiles are fired at elevation angles at a muzzle velocity of Mach 2 from a large caliber howitzer equipped with a newly designed double-baffle muzzle brake. In the near field, pressure signatures of the N-wave generated from projectiles are measured by 32-microphone ring array wrapped by cotton sheath. Records measured by the microphone array are used to demonstrate several key characteristics of the shock wave of supersonic projectile. All measurements made in this study can be a significant reference for developing guns, tanks, or the chassis of fighting vehicles.
Characteristics and measurement of supersonic projectile shock waves by a 32-microphone ring array.
Chang, Ho; Wu, Yan-Chyuan; Tsung, Tsing-Tshih
2011-08-01
This paper discusses about the characteristics of supersonic projectile shock wave in muzzle region during firing of high explosive anti-tank (HEAT) and high explosive (HE) projectiles. HEAT projectiles are fired horizontally at a muzzle velocity of Mach 3.5 from a medium caliber tank gun equipped with a newly designed multi-perforated muzzle brake, whereas HE projectiles are fired at elevation angles at a muzzle velocity of Mach 2 from a large caliber howitzer equipped with a newly designed double-baffle muzzle brake. In the near field, pressure signatures of the N-wave generated from projectiles are measured by 32-microphone ring array wrapped by cotton sheath. Records measured by the microphone array are used to demonstrate several key characteristics of the shock wave of supersonic projectile. All measurements made in this study can be a significant reference for developing guns, tanks, or the chassis of fighting vehicles.
2017-11-01
From left, Col. Z. Walter Jackim, vice commander, 45th Space Wing, Cape Canaveral Air Force Station; Michael Good, assistant fire management officer, Merritt Island National Wildlife Refuge; John Fish, chief, Florida Forest Service; Mark Schollmeyer, chief, Brevard County Fire Rescue; and Kelvin Manning, associate director, NASA's Kennedy Space Center, pose for a portrait following a ceremony Nov. 1 on the Merritt Island National Wildlife Refuge in Florida. During the joint ceremony, the Spaceport Integration Team and its partners were presented with the prestigious 2017 Pulaski Award and a new memorial marker was dedicated. The multi-agency team includes representatives from NASA's Kennedy Space Center, Cape Canaveral Air Force Station's 45th Space Wing, the Merritt Island National Wildlife Refuge, as well as the Florida Forest Service and Brevard County Fire Rescue. The memorial marker honors two fallen firefighters, Scott Maness and Beau Sauselein, who died fighting a wildfire on space center property in 1981. Held outdoors, the ceremony was attended by 140 guests.
Persistent neurotoxicity from a battery fire: is cadmium the culprit?
Kilburn, K H; McKinley, K L
1996-07-01
Two train conductors had chest tightness, painful breathing, muscle cramps, and nausea after fighting a fire in a battery box under a passenger coach. Shortly thereafter, they became anosmic and had excessive fatigue, persistent headaches, sleep disturbances, irritability, unstable moods, and hypertension. Urinary cadmium and nickel levels were elevated. Neurobehavioral testing showed, in comparison to referents, prolonged reaction times, abnormal balance, prolonged blink reflex latency, severely constricted visual fields, and decreased vibration sense. Test scores showed that immediate verbal and visual recall were normal but delayed recall was reduced. Scores on overlearned information were normal. Tests measuring dexterity, coordination, decision making, and peripheral sensation and discrimination revealed abnormalities. Repeat testing 6 and 12 months after exposure showed persistent abnormalities. Cadmium and vinyl chloride are the most plausible causes of the neurotoxicity, but fumes from the fire may have contained other neurotoxic chemicals.
Hoover, Kevin M.; Bubak, Andrew N.; Law, Isaac J.; Yaeger, Jazmine D. W.; Renner, Kenneth J.; Swallow, John G.; Greene, Michael J.
2016-01-01
Abstract Ant colonies self-organize to solve complex problems despite the simplicity of an individual ant’s brain. Pavement ant Tetramorium caespitum colonies must solve the problem of defending the territory that they patrol in search of energetically rich forage. When members of 2 colonies randomly interact at the territory boundary a decision to fight occurs when: 1) there is a mismatch in nestmate recognition cues and 2) each ant has a recent history of high interaction rates with nestmate ants. Instead of fighting, some ants will decide to recruit more workers from the nest to the fighting location, and in this way a positive feedback mediates the development of colony wide wars. In ants, the monoamines serotonin (5-HT) and octopamine (OA) modulate many behaviors associated with colony organization and in particular behaviors associated with nestmate recognition and aggression. In this article, we develop and explore an agent-based model that conceptualizes how individual changes in brain concentrations of 5-HT and OA, paired with a simple threshold-based decision rule, can lead to the development of colony wide warfare. Model simulations do lead to the development of warfare with 91% of ants fighting at the end of 1 h. When conducting a sensitivity analysis, we determined that uncertainty in monoamine concentration signal decay influences the behavior of the model more than uncertainty in the decision-making rule or density. We conclude that pavement ant behavior is consistent with the detection of interaction rate through a single timed interval rather than integration of multiple interactions. PMID:29491915
Hoover, Kevin M; Bubak, Andrew N; Law, Isaac J; Yaeger, Jazmine D W; Renner, Kenneth J; Swallow, John G; Greene, Michael J
2016-06-01
Ant colonies self-organize to solve complex problems despite the simplicity of an individual ant's brain. Pavement ant Tetramorium caespitum colonies must solve the problem of defending the territory that they patrol in search of energetically rich forage. When members of 2 colonies randomly interact at the territory boundary a decision to fight occurs when: 1) there is a mismatch in nestmate recognition cues and 2) each ant has a recent history of high interaction rates with nestmate ants. Instead of fighting, some ants will decide to recruit more workers from the nest to the fighting location, and in this way a positive feedback mediates the development of colony wide wars. In ants, the monoamines serotonin (5-HT) and octopamine (OA) modulate many behaviors associated with colony organization and in particular behaviors associated with nestmate recognition and aggression. In this article, we develop and explore an agent-based model that conceptualizes how individual changes in brain concentrations of 5-HT and OA, paired with a simple threshold-based decision rule, can lead to the development of colony wide warfare. Model simulations do lead to the development of warfare with 91% of ants fighting at the end of 1 h. When conducting a sensitivity analysis, we determined that uncertainty in monoamine concentration signal decay influences the behavior of the model more than uncertainty in the decision-making rule or density. We conclude that pavement ant behavior is consistent with the detection of interaction rate through a single timed interval rather than integration of multiple interactions.
John F Stewart; Rodney E Will; Kevin M Robertson; Dana Nelson
2014-01-01
Across much of the globe, fire is a major disturbance agent of forest and grassland communities. The removal of fire from previously fire-maintained ecosystems, which has occurred in many areas, changes species composition, favoring later less fire tolerant species over fire-adapted ones. A recent measured increase in the rate of hybridization between the fire-adapted...
1999-09-01
Verify that all personnel new to the career field receive a baseline physical exam prior to potential occupational exposure to pesticides and periodic...or using toilet facilities -persons working regularly with organophosphates and N-alkyl carbamate pesticides have periodic physical examinations...after fighting fires involving organophosphate or N-alkyl carbamate pesticides. 7-37 Pesticide 7-38 Pesticide COMPLIANCE CATEGORY
Operator’s Manual. Prototype Heavy Rescue/Fire Fighting Vehicle
1980-09-01
system for emergency operation if pressure is lost in either parking or service brake systems . The system is operational automatically and is...controlled by the foot treadle ’sive. It will provide for TWO full brake applications and ONE release. ELECTRICAL SYSTEM A dual battery system is utilized for...cleaner. * Lubricate chassis. . Repack wheel bearings. . Inspect brake system and adjust brakes . . Replace fuel filter. . Check high and low idle.
14 CFR 23.1201 - Fire extinguishing systems materials.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fire extinguishing systems materials. 23... Powerplant Powerplant Fire Protection § 23.1201 Fire extinguishing systems materials. Link to an amendment... material in any fire extinguishing system may react chemically with any extinguishing agent so as to create...
NASA Astrophysics Data System (ADS)
Martin, D. A.; Tindall, J.
2008-12-01
Precipitation falling on forests and grasslands provides much of the water to communities across the United States. The U.S. Forest Service estimates that over 3,400 communities are served by water draining land under its jurisdiction alone. Much of this land is subject to wildland fires, which have been increasing in size and severity in the western United States in response to climatic forcing and increased ignitions from human sources. Runoff from burned landscapes can present a significant risk to municipal and agricultural water supplies from ash, sediment, contaminants from burned structures, and fire-fighting chemicals. Several municipalities, including Denver, Colorado, have experienced both short-term and long-term degradation of their water supplies in the aftermath of fires in watersheds upstream from drinking water reservoirs. Scientific efforts to predict and mitigate the effects of catastrophic fire on water supplies have focused on three areas. The first consists of data collection and carefully designed experiments to understand the change of the hydrologic behavior of burned watersheds in response to rain with different intensities, durations, and trajectories as the watersheds recover. Results from these studies are used to validate models that predict watershed response under different initial conditions constrained by remotely-sensed burn severity, topography, rainfall-intensity recurrence probabilities and other factors. These predictions are the basis for rehabilitation measures applied to the landscape to minimize post-fire runoff and erosion. Efforts are under way to incorporate the chemical effects of ash and fire-fighting compounds in decision-support tools. A second area of scientific focus is the characterization of the chemical and physical properties of ash from wildland fire, including ash from structures consumed by fire. The ash chemistry is correlated to remotely- sensed data, type of vegetation that burned, and the underlying geology. Ash affects the hydraulic properties and behavior of soils in burned watersheds while it still mantles the hillslopes, but it is easily delivered to water bodies by rain and wind as a flush of material that affects water chemistry and properties like turbidity and temperature. A third thrust is to identify watersheds that are critical to the function of municipal water supplies and infrastructure to determine their vulnerability to fire and post-fire effects. This information can be used to prioritize areas for fuel treatments or land management practices to minimize the probability of high severity fire and hence the effects of post-fire runoff. Scientific studies are providing crucial information about such topics as changes in soil erodibility, infiltration and runoff after fire, and the effects of vegetation recovery. Even in watersheds where land management actions are limited by topography or land use designation, such as wilderness areas, knowledge of the potential response of burned areas allows water providers to develop rapid-response and long-term plans based on scientific data and tools. Some climate change models are predicting hotter, drier temperatures in certain areas of the United States and a higher probability of larger, more severe wildfires. These predictions have a direct bearing on the potential risk of impairment of water supplies by post-fire runoff and erosion. In an era when water availability and quality are of utmost importance, careful scientific studies focused on the effects of wildland fire on water supplies will continue to inform public policy and decision making on topics of vulnerability and risk reduction.
Fire extinguishing agents for oxygen-enriched atmospheres
NASA Astrophysics Data System (ADS)
Plugge, M. A.; Wilson, C. W.; Zallen, D. M.; Walker, J. L.
1985-12-01
Fire-suppression agent requirements for extinguishing fires in oxygen-enriched atmospheres were determined employing small-, medium-, large-, and full-scale test apparatuses. The small- and medium-scale tests showed that a doubling of the oxygen concentration required five times more HALON for extinguishment. For fires of similar size and intensity, the effect of oxygen enrichment of the diluent volume in the HC-131A was not as grate as in the smaller compartments of the B-52 which presented a higher damage scenario. The full-scale tests showed that damage to the airframe was as important a factor in extinguishment as oxygen enrichment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hazlett, R.N.; Affens, W.A.; McLaren, G.W.
1978-05-01
Fire extinguishment experiments with JP-5 jet fuels derived from shale crude oil and also from petroleum (for comparison) were conducted at NRL's Chesapeake Bay facility. The experiments were conducted in a 40-foot diameter circular pool using Aqueous Film Forming Foam (AFFF) as the fire extinguishing agent. The results with both types of fuel were similar, and it was concluded that the techniques and agents for AFFF application, which have been developed for petroleum fuel fires, can also be used for shale derived jet fuel.
Littell, Jeremy
2015-01-01
Time-varying fire-climate relationships may represent an important component of fire-regime variability, relevant for understanding the controls of fire and projecting fire activity under global-change scenarios. We used time-varying statistical models to evaluate if and how fire-climate relationships varied from 1902-2008, in one of the most flammable forested regions of the western U.S.A. Fire-danger and water-balance metrics yielded the best combination of calibration accuracy and predictive skill in modeling annual area burned. The strength of fire-climate relationships varied markedly at multi-decadal scales, with models explaining < 40% to 88% of the variation in annual area burned. The early 20th century (1902-1942) and the most recent two decades (1985-2008) exhibited strong fire-climate relationships, with weaker relationships for much of the mid 20th century (1943-1984), coincident with diminished burning, less fire-conducive climate, and the initiation of modern fire fighting. Area burned and the strength of fire-climate relationships increased sharply in the mid 1980s, associated with increased temperatures and longer potential fire seasons. Unlike decades with high burning in the early 20th century, models developed using fire-climate relationships from recent decades overpredicted area burned when applied to earlier periods. This amplified response of fire to climate is a signature of altered fire-climate-relationships, and it implicates non-climatic factors in this recent shift. Changes in fuel structure and availability following 40+ yr of unusually low fire activity, and possibly land use, may have resulted in increased fire vulnerability beyond expectations from climatic factors alone. Our results highlight the potential for non-climatic factors to alter fire-climate relationships, and the need to account for such dynamics, through adaptable statistical or processes-based models, for accurately predicting future fire activity.
Higuera, Philip E.; Abatzoglou, John T.; Littell, Jeremy S.; Morgan, Penelope
2015-01-01
Time-varying fire-climate relationships may represent an important component of fire-regime variability, relevant for understanding the controls of fire and projecting fire activity under global-change scenarios. We used time-varying statistical models to evaluate if and how fire-climate relationships varied from 1902-2008, in one of the most flammable forested regions of the western U.S.A. Fire-danger and water-balance metrics yielded the best combination of calibration accuracy and predictive skill in modeling annual area burned. The strength of fire-climate relationships varied markedly at multi-decadal scales, with models explaining < 40% to 88% of the variation in annual area burned. The early 20th century (1902-1942) and the most recent two decades (1985-2008) exhibited strong fire-climate relationships, with weaker relationships for much of the mid 20th century (1943-1984), coincident with diminished burning, less fire-conducive climate, and the initiation of modern fire fighting. Area burned and the strength of fire-climate relationships increased sharply in the mid 1980s, associated with increased temperatures and longer potential fire seasons. Unlike decades with high burning in the early 20th century, models developed using fire-climate relationships from recent decades overpredicted area burned when applied to earlier periods. This amplified response of fire to climate is a signature of altered fire-climate-relationships, and it implicates non-climatic factors in this recent shift. Changes in fuel structure and availability following 40+ yr of unusually low fire activity, and possibly land use, may have resulted in increased fire vulnerability beyond expectations from climatic factors alone. Our results highlight the potential for non-climatic factors to alter fire-climate relationships, and the need to account for such dynamics, through adaptable statistical or processes-based models, for accurately predicting future fire activity. PMID:26114580