Sample records for fire fighting foam

  1. ZrP nanoplates based fire-fighting foams stabilizer

    NASA Astrophysics Data System (ADS)

    Zhang, Lecheng; Cheng, Zhengdong; Li, Hai

    2015-03-01

    Firefighting foam, as a significant innovation in fire protection, greatly facilitates extinguishments for liquid pool fire. Recently, with developments in LNG industry, high-expansion firefighting foams are also used for extinguishing LNG fire or mitigating LNG leakage. Foam stabilizer, an ingredient in fire-fighting foam, stabilizes foam bubbles and maintains desired foam volume. Conventional foam stabilizers are organic molecules. In this work, we developed a inorganic based ZrP (Zr(HPO4)2 .H2O, Zirconium phosphate) plates functionalized as firefighting foam stabilizer, improving firefighting foam performance under harsh conditions. Several tests were conducted to illustrate performance. The mechanism for the foam stabilization is also proposed. Artie McFerrin Department of Chemical Engineering, Texas A&M University, College Station, TX 77843, USA. Mary Kay O'Connor Process Safety Center, Texas A&M University, College Station, TX, 77843-3122

  2. Potential production of palm oil-based foaming agent as fire extinguisher of peatlands in Indonesia: Literature review

    NASA Astrophysics Data System (ADS)

    Subekti, P.; Hambali, E.; Suryani, A.; Suryadarma, P.

    2017-05-01

    This study aims to analyze the potential aplication of of palm oil-based foaming agent as peat fires fighter in Indonesia. From literature review, it has been known that the foaming agent able to form foam to extinguish fire, wrap and refrigerate the burning peat. It is necessary to develop the production and application of foaming agent in Indonesia because peat fires occur almost every year that caused smoke haze. Potential raw material for the production of environmental friendly foaming agent as foam extinguishing for peat fires in Indonesia aong other is palm oil due to abundant availability, sustainable, and foam product easily degraded in the environment of the burnt areas. Production of foaming agent as fire-fighting in Indonesia is one alternative to reduce the time to control the fire and smog disaster impact. Application of palm oil as a raw material for fire-fighting is contribute to increase the value added and the development of palm oil downstream industry.

  3. Biodegradability of fluorinated fire-fighting foams in water.

    PubMed

    Bourgeois, A; Bergendahl, J; Rangwala, A

    2015-07-01

    Fluorinated fire-fighting foams may be released into the environment during fire-fighting activities, raising concerns due to the potential environmental and health impacts for some fluorinated organics. The current study investigated (1) the biodegradability of three fluorinated fire-fighting foams, and (2) the applicability of current standard measures used to assess biodegradability of fluorinated fire-fighting foams. The biodegradability of three fluorinated fire-fighting foams was evaluated using a 28-day dissolved organic carbon (DOC) Die-Away Test. It was found that all three materials, diluted in water, achieved 77-96% biodegradability, meeting the criteria for "ready biodegradability". Defluorination of the fluorinated organics in the foam during biodegradation was measured using ion chromatography. It was found that the fluorine liberated was 1-2 orders of magnitude less than the estimated initial amount, indicating incomplete degradation of fluorinated organics, and incomplete CF bond breakage. Published biodegradability data may utilize biochemical oxygen demand (BOD), chemical oxygen demand (COD), and total organic carbon (TOC) metrics to quantify organics. COD and TOC of four fluorinated compounds were measured and compared to the calculated carbon content or theoretical oxygen demand. It was found that the standard dichromate-based COD test did not provide an accurate measure of fluorinated organic content. Thus published biodegradability data using COD for fluorinated organics quantification must be critically evaluated for validity. The TOC measurements correlated to an average of 91% of carbon content for the four fluorinated test substances, and TOC is recommended for use as an analytical parameter in fluorinated organics biodegradability tests. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Universal Stationary/Mobile NoFoam Unit (USNOFU) for Aircraft Rescue and Fire Fighting (ARFF) Vehicles

    DTIC Science & Technology

    2004-01-01

    AFFF aqueous film forming foam AFRL Air Force Research Laboratory ARFF Aircraft Rescue and...distribution system checks use a fire-fighting agent called aqueous film forming foam ( AFFF ) and generate significant amounts of AFFF wastewater. Despite its...but it has been classified as persistent, bioaccumulative, and toxic (PBT). As a result, the AFFF wastewater resulting from foam distribution

  5. Synthesis of palm oil fatty acid as foaming agent for firefighting application

    NASA Astrophysics Data System (ADS)

    Rivai, M.; Hambali, E.; Suryani, A.; Fitria, R.; Firmansyah, S.; Pradesi, J.

    2017-05-01

    Many factors including natural factor, human carelessness, new land clearance or agricultural burning/act of vandalism and ground fire are suspected as the causes of forest fire. Foam, which cools the fire down, covers the burning material/fuel, and avoids contact between burning materials with oxygen, is an effective material used to fight large-scale fires. For this purpose, surfactant which can facilitate foam formation and inhibit the spread of smoke is required. This study was aimed at producing prototype product of foaming agent from palm oil and its formulation as a fire fighting material. Before the formulation stage, the foaming agent was resulted from saponification process of oleic, lauric, and palmitic acids by using NaOH and KOH alkaline. Foam stability was used as the main indicator of foaming agent. Results showed that potassium palmitate had the highest foam stability of 82% until the 3rd day. The best potassium palmitate concentration was 7%.

  6. Inflatable partition for fighting mine fires

    DOEpatents

    Conti, Ronald S.; Lazzara, Charles P.

    1995-01-01

    The seal is a lightweight, inflatable, bag which may be inflated by a portable air generator and is used to seal a burning mine passage. A collapsible tube-like aperture extends through the seal and allows passage of high expansion foam through the seal in a feed tube. The foam fills the passageway and extinguishes the fire. In other embodiments, the feed tubes incorporate means to prevent collapse of the aperture. In these embodiments a shroud connects the feed tube to a foam generator. This seal allows creation of a high expansion foam fire fighting barrier even in upward sloping passages.

  7. Rheology of Foam Near the Order-Disorder Phase Transition

    NASA Technical Reports Server (NTRS)

    Holt, R. Glynn; McDaniel, J. Gregory

    1999-01-01

    Foams are extremely important in a variety of industrial applications. Foams are widely used in fire-fighting applications, and are especially effective in fighting flammable liquid fires. In fact the Fire Suppression System aboard the Space Shuttle utilizes cylinders of Halon foam, which, when fired, force a rapidly expanding foam into the convoluted spaces behind instrument panels. Foams are critical in the process of enhanced oil recovery, due to their surface-active and highly viscous nature. They are also used as drilling fluids in underpressurized geologic formations. They are used as transport agents, and as trapping agents. They are also used as separation agents, where ore refinement is accomplished by froth flotation of the typically lighter and hydrophobic contaminants. The goal of the proposed investigation is the determination of the mechanical and rheological properties of foams, utilizing the microgravity environment to explore foam rheology for foams which cannot exist, or only exist for a short time, in 1g.

  8. Treatability of Aqueous Film-Forming Foams Used for Fire Fighting.

    DTIC Science & Technology

    BIODETERIORATION, *FIRE EXTINGUISHING AGENTS, SURFACE ACTIVE SUBSTANCES, FLUORINATED HYDROCARBONS, FOAM , ACTIVATED SLUDGE PROCESS, ACTIVATED CARBON, TOXICITY, WASTE DISPOSAL, TABLES(DATA), ADSORPTION.

  9. Extinguishment and Burnback Testing of Fire Fighting Agents

    DTIC Science & Technology

    2005-09-26

    resisting burnback for hydrocarbon fuel fires. Potential Aqueous Film Forming Foam ( AFFF ) replacements are required to exhibit an...simple, reliable test to evaluate the effectiveness of new foams being introduced into the market as potential Aqueous Film Forming Foam ( AFFF ...normal concentrations. Reference: Military Specification MIL-F-24385F, Fire Extinguishing Agent, Aqueous Film - Forming Foam

  10. Aircraft Hangar Fire Suppression System Evaluation-Intermediate- Scale Studies

    DTIC Science & Technology

    1999-12-23

    aqueous film forming foam ( AFFF ) extinguishing systems [1]. The overhead AFFF system typically consists of standard closed head sprinklers that...of Water Spray on Fire-Fighting Foam ," Fire Journal, 63 (6), November 1969. 5. MIL-F-24385F, "Fire Extinguishing Agent, Aqueous Film Forming Foam ...extinguishing capability of the foam and the ability of the blanket to resist burnback. When AFFF is applied over a flammable liquid spill

  11. Biocatalytic nerve agent detoxification in fire fighting foams.

    PubMed

    LeJeune, K E; Russell, A J

    1999-03-20

    Current events across the globe necessitate rapid technological advances to combat the epidemic of nerve agent chemical weapons. Biocatalysis has emerged as a viable tool in the detoxification of organophosphorus neurotoxins, such as the chemical weapons VX and sarin. Efficient detoxification of contaminated equipment, machinery, and soils are of principal concern. This study describes the incorporation of a biocatalyst (organophosphorus hydrolase, E.C. 3.1.8.1) into conventional formulations of fire fighting foam. The capacity of fire fighting foams to decrease volatilization of contained contaminants, increase surface wettability, and control the rate of enzyme delivery to large areas makes them useful vehicles for enzyme application at surfaces. The performance of enzyme containing foams has been shown to be not only reproducible but also predictable. An empirical model provides reasonable estimations for the amounts of achievable surface decontamination as a function of the important parameters of the system. Theoretical modeling illustrates that the enzyme-containing foam is capable of extracting agent from the surface and is catalytically active at the foam-surface interface and throughout the foam itself. Biocatalytic foam has proven to be an effective, "environmentally friendly" means of surface and soil decontamination.

  12. Aquatic Toxicity Screening of Fire Fighting Agents

    DTIC Science & Technology

    2005-09-21

    Aqueous Film Forming Foam ( AFFF ), the reference toxicant. The aquatic toxicity...Specification MIL-F-24385F Fire Extinguishing Agent, Aqueous Film Forming Foam ( AFFF ) Liquid Concentrate, For Fresh and Sea Water (MIL SPEC AFFF ). This...extinguish liquid hydrocarbon fuel fires involving aircraft operations. Several types of foam exist including protein, fluoroprotein and aqueous film

  13. Evaluation of three percent Aqueous Film Forming Foam (AFFF) concentrates as fire fighting agents

    NASA Astrophysics Data System (ADS)

    Jablonski, E. J.

    1981-04-01

    A large-scale fire test program involving 20,000-square foot JP-4 fuel fires was conducted to evaluate the fire suppression effectiveness and compatibility of 3 percent Aqueous Film Forming Foam (AFFF) agents in Air Force fire fighting vehicles. Three commercially available 3 percent AFFF concentrates were tested in accordance with military specification MIL-F-24385B. Test results are summarized in Appendix A. As a result of these tests, an updated Revision C to this MIL SPEC has been accomplished with new requirements for both 3 percent and 6 percent AFFF extinguishing agents.

  14. Aquatic Toxicity Screening of Fire Fighting Agents; 2003 Report

    DTIC Science & Technology

    2003-06-02

    Aqueous Film Forming Foam ( AFFF ), the reference toxicant. The aquatic toxicity screening consisted of an acute, static, range-finding...five concentrations of 3M Light Water Brand Aqueous Film Forming Foam ( AFFF ), the reference toxicant. The aquatic toxicity screening consisted of an...experimental foam concentrates against current Military Specification MIL-F-24385F Fire Extinguishing Agent, Aqueous Film Forming Foam

  15. Fire Extinguishing Agents, Aqueous Film Forming Foam (AFFF) Liquid Concentration Partial Percentage

    DTIC Science & Technology

    1989-08-31

    AFFF concentrations. aqueous film forming foam , AFFF , firefighting ...Extinguishing Agents, Aqueous Film Forming Foam ( AFFF ) Liquid Concentration Partial Percentage F08637-88-C-0067 06022104F 2104 30 21043034 Applied Research...objective of this test series was to qualify 3/4 and 1 percent Aqueous Film Forming Foam ( AFFF ) concentrate for use in Air Force fire fighting

  16. Acute toxicity of three fire-retardant and two fire-suppressant foam formulations to the early life stages of rainbow trout (Oncorhynchus mykiss)

    USGS Publications Warehouse

    Gaikowski, Mark P.; Hamilton, Steven J.; Buhl, Kevin J.; McDonald, Susan F.; Summers, Cliff H.; Linder, G.; Krest, S.; Sparling, D.; Little, E.

    1996-01-01

    Laboratory studies were conducted with five early life stages of rainbow trout, Oncorhynchus mykiss, to determine the acute toxicities of five fire-fighting chemical formulations in standardized soft and hard water. Eyed egg, embryo–larvae, swim-up fry, and 60- and 90-d posthatch juveniles were exposed to three fire retardants (Fire-Trol LCG-R, Fire-Trol GTS-R, and Phos-Chek D75-F) and two fire-suppressant foams (Phos-Chek WD-881 and Silv-Ex). Swim-up fry were generally the most sensitive life stage, whereas the eyed-egg was the least sensitive. Toxicity of fire-fighting formulations was greater in hard water than in soft water for all life stages tested with Fire-Trol GTS-R and Silv-Ex and for 90-d-old juveniles tested with Fire-Trol LCG-R. The fire-suppressant foams were more toxic than the fire retardants. The 96-h median lethal concentrations (LC50s) were ranked from the most toxic to the least toxic formulation as follows (ranges are the lowest and highest 96-h LC50 calculated for each formulation): Phos-Chek WD-881 (11–44 mg/L), Silv-Ex (11–78 mg/L), Phos-Chek D75-F (218–>3,600 mg/L), Fire-Trol GTS-R (207–>6,000 mg/L), and Fire-Trol LCG-R (872–>10,000 mg/L). Toxicity values suggest that accidental entry of fire-fighting chemicals into aquatic environments could adversely affect fish populations.

  17. The Wildland/Urban Interface in 2025

    Treesearch

    Gary O. Tokle

    1987-01-01

    In the year 2025, wildland fire fighting practices have improved significantly over the method employed during the late1900's. Improved methods for predicting severe fire weather conditions, the establishment of the North American Fire Coordination Center, and the utilization of foam products for both wildfire and structural fire control have significantly changed...

  18. DETERMINATION OF PERFLUOROCARBOXYLATES IN GROUNDWATER IMPACTED BY FIRE-FIGHTING ACTIVITY. (R821195)

    EPA Science Inventory

    Perfluorinated surfactants are used in aqueous film forming foam (AFFF)
    formulations, which are used to extinguish hydrocarbon-fuel fires. Virtually
    nothing is known about the occurrence of perfluorinated surfactants in the
    environment, in particular, at fire-train...

  19. 77 FR 38275 - Notice of Intent To Grant Exclusive Patent License; Emerging Growth Enterprise LLC

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-27

    ..., nonassignable, exclusive license to practice in the field of fire fighting foam discharge and suppression... November 6, 2007) and entitled, ``Nofoam system for testing a foam delivery system on a vehicle'', No. 7,293,478 (Issued November 13, 2007) and entitled ``Method for testing a foam delivery system on a...

  20. Advanced Catalytic Enzyme System (ACES) - Dual Use Capabilities

    DTIC Science & Technology

    2003-07-01

    Novozymes A/S (Bagsvaerd, Denmark) with activity against both cells and spores, and a bacteriophage enzyme (PlyG Lysin) that is specific for B. anthracis... Novozymes ), Lysozyme (commercial) Buffer: Ammonium carbonate Fire-Fighting Components: ColdFire®, Fire Choke® or an equivalent Class A foam The

  1. Testing of Fire Fighting Foam.

    DTIC Science & Technology

    1980-11-01

    for Fresh and Sea Water ( MIL - F - 24385 ); -(C) Underwriters Laboratories Inc. S andard for Air Foam Equipment and Liquid Con- centrates (UL162);4D...C. Test Facilities 6 D. Test Procedures 7 III. Results of Tests A. FRN-1007 33 B. MIL - F - 24385 34 C. UL 162 34 D. O- F -555C 35 E. Foam Quality 35 IV...1 gpm) H N-heptane in. inch (25.4 mm = 1 in.) ipm liters per minute M Motor Octane Rating MIL MIL - F - 24385 Test Method NFPA National Fire Protection

  2. Heat shields for aircraft - A new concept to save lives in crash fires.

    NASA Technical Reports Server (NTRS)

    Neel, C. B.; Parker, J. A.; Fish, R. H.; Henshaw, J.; Newland, J. H.; Tempesta, F. L.

    1971-01-01

    A passenger compartment surrounded by a fire-retardant shell, to protect the occupants long enough for the fire to burn out or for fire-fighting equipment to reach the aircraft and extinguish it, is proposed as a new concept for saving lives in crash fires. This concept is made possible by the recent development of two new fire-retardant materials: a very lightweight foam plastic, called polyisocyanurate foam, and an intumescent paint. Exposed to heat, the intumescent paint expands to many times its original thickness and insulates the surface underneath it. Demonstration tests are illustrated, described and discussed. However, some problems, such as preventing fuselage rupture and protecting windows, must be solved before such a system can be used.

  3. Evaluation of Three Percent Aqueous Film Forming Foam (AFFF) Concentrates as Fire Fighting Agents.

    DTIC Science & Technology

    1981-04-01

    Three percent AFFF formulations are currently available to meet the requirements of proposed Revision C to Military Specifi- cation MIL - F - 24385 . The fire...also result in savings for shipping and storage costs. Therefore, Appendix B contains proposed Revision C to MIL - F - 24385 . It includes requirements for

  4. 46 CFR 167.45-40 - Fire-fighting equipment on nautical school ships using oil as fuel.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... following type and character: (a) In each boiler room and in each of the machinery spaces of a nautical... approved fire extinguishers of the foam type of not less than 9.5 liters (21/2 gallons) each or 2 or more approved fire extinguishers of the carbon dioxide type of not less than 33 kilograms (15 pounds) each must...

  5. 46 CFR 167.45-40 - Fire-fighting equipment on nautical school ships using oil as fuel.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... following type and character: (a) In each boiler room and in each of the machinery spaces of a nautical... approved fire extinguishers of the foam type of not less than 9.5 liters (21/2 gallons) each or 2 or more approved fire extinguishers of the carbon dioxide type of not less than 33 kilograms (15 pounds) each must...

  6. Guide Specification For Water/Foam Aircraft Rescue and Firefighting Vehicles

    DOT National Transportation Integrated Search

    2002-02-18

    This advisory circular (AC) contains performance standards, specifications, and : recommendations for the design, construction, and testing of a family of : aircraft rescue and fire fighting (ARFF) vehicles. The guide specifications : covers two clas...

  7. Evaluation of the Effects of AFFF Inputs on the VIP Biological Nutrient Removal Process and Pass-Through Toxicity.

    DTIC Science & Technology

    1999-01-01

    AFFF ( aqueous film - forming foam ), is widely used by the U.S. Navy in fire fighting water to improve the ability to control petroleum...Chan, D. B., (1978). " Disposal of Wastewater Containing Aqueous Film Forming Foam ." Technical Memorandum No. M-54-78-06, Civil Engineering...Inmand, R.C. (1975). "Biodegradability and Toxicity of ANSUL K74-100, Aqueous Film Forming Foam ." Report No. EHL(K) 75-3, USAF Environmental

  8. 46 CFR Appendix B to Subpart C of... - Substance Technical Guidelines, Benzene

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...) Extinguishing media: Carbon dioxide, dry chemical, or foam. (5) Special fire fighting procedures: Do not use a... ignited by open flames or sparks at locations remote from the site at which benzene is handled. (7...

  9. 46 CFR Appendix B to Subpart C to... - Substance Technical Guidelines, Benzene

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) Extinguishing media: Carbon dioxide, dry chemical, or foam. (5) Special fire fighting procedures: Do not use a... ignited by open flames or sparks at locations remote from the site at which benzene is handled. (7...

  10. 46 CFR Appendix B to Subpart C of... - Substance Technical Guidelines, Benzene

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) Extinguishing media: Carbon dioxide, dry chemical, or foam. (5) Special fire fighting procedures: Do not use a... ignited by open flames or sparks at locations remote from the site at which benzene is handled. (7...

  11. Possibility of increasing the fire-suppression efficiency of the foam in automatic extinguishing installations

    NASA Astrophysics Data System (ADS)

    Kachanov, I. V.; Veremenyuk, V. V.; Karpenchuk, I. V.; Pavlyukov, S. Yu.

    2013-05-01

    The mechanics of movement of a liquid in the diffuser of the injector of an automatic extinguishing installation with preaeration of the fire-fighting substance was theoretically investigated. An integral solution of the equation for movement of the preaerated fire-fighting gas-liquid mixture in the indicated diffuser has been obtained. A mathematical model of two-phase liquid flow in this diffuser, which allows one to calculate the distribution of the average pressure in the diffuser along its length and to determine the loss in this pressure, has been developed. This model can be used for designing the output region of a hydraulic system with a hydrodynamic drag providing the operation of its injector in a definite regime.

  12. Toxicokinetics of perfluorooctanoate (PFOA) in rainbow trout(Oncorhynchus mykiss)

    EPA Science Inventory

    Perfluoroalkyl acids (PFAAs) are widely used as stain resistant coatings for cloth, paper, and leather, and as surfactants, fire-fighting foams, and photographic developers. Individual PFAAs have been shown to accumulate in fish and wildlife; however, the extent of this accumulat...

  13. 76 FR 11449 - Agency Information Collection Activities; Submission to OMB for Review and Approval; Comment...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-02

    ... Reading Room is open from 8 a.m. to 4:30 p.m., Monday through Friday, excluding legal holidays. The...-icers and fire-fighting foams. Safer surfactants are those that break down quickly to non-polluting...

  14. 75 FR 71123 - Agency Information Collection Activities; Proposed Collection; Comment Request; Safer Detergent...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-22

    ...-HQ-OPPT-2010-0874. The DCO is open from 8 a.m. to 4 p.m., Monday through Friday, excluding legal..., cleaners, airplane deicers, and fire-fighting foams. Safer surfactants are those that break down quickly to...

  15. Materials Applications for Non-Lethal: Aqueous Foams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    GOOLSBY,TOMMY D.; SCOTT,STEVEN H.

    High expansion aqueous foam is an aggregation of bubbles that has the appearance of soap suds and is used to isolate individuals both visually and acoustically. It was developed in the 1920's in England to fight coal mine fires and has been widely used since for fire fighting and dust suppression. It was developed at Sandia National Laboratories (SNL) in the 1970's for nuclear safeguards and security applications. In the mid-1990s, the National Institute of Justice (NIJ), the research arm of the Department of Justice, began a project with SNL to determine the applicability of high expansion aqueous foam formore » correctional applications. NIJ funded the project as part of its search for new and better less-than-lethal weapons for responding to violent and dangerous individuals, where other means of force could lead to serious injuries. The phase one objectives of the project were to select a low-to-no toxicity foam concentrate (foaming agent) with physical characteristics suited for use in a single cell or large prison disturbances, and to determine if the selected foam concentrate could serve as a carrier for Oleoresin Capsicum (OC) irritant. The phase two objectives were to conduct an extensive toxicology review of the selected foam concentrate and OC irritant, and to conduct respiration simulation experiments in the selected high expansion aqueous foam. The phase three objectives were to build a prototype individual cell aqueous foam system and to study the feasibility of aqueous foams for large prison facility disturbances. The phase four and five objectives were to use the prototype system to do large scale foam physical characteristics testing of the selected foam concentrate, and to have the prototype single cell system further evaluated by correctional representatives. Prison rather than street scenarios were evaluated as the first and most likely place for using the aqueous foam since prisons have recurrent incidents where officers and inmates might be seriously injured during violent confrontations. The very low density of the high expansion foam also makes it more suitable for indoor use. This paper summarizes the results of the project.« less

  16. Aqueous foam as a less-than-lethal technology for prison applications

    NASA Astrophysics Data System (ADS)

    Goolsby, Tommy D.

    1997-01-01

    High expansion aqueous foam is an aggregation of bubbles that has the appearance of soap suds and is used to isolate individuals both visually and acoustically. It was developed in the 1920's in England to fight coal mine fires and has been widely used since for fire fighting and dust suppression. It was developed at Sandia National Laboratories (SNL) in the 1970's for nuclear safeguards and security applications. In late 1994, the National Institute of Justice (NIJ), the research arm of the Department of Justice, began a project with SNL to determine the applicability of high expansion aqueous foam for correctional applications. NIJ funded the project as part of its search for new and better less-than-lethal weapons for responding to violent and dangerous individuals, where other means of force could lead to serious injuries. The phase one objectives of the project were to select a low-to-no toxicity foam concentrate with physical characteristics suited for use in a single cell or large prison disturbances, and to determine if the selected foam concentrate could serve as a carrier for Oleoresin Capsicum (OC) irritant. The phase two objective were to conduct an extensive toxicology review of the selected foam concentrate and OC irritant, and to conduct respiration simulation experiments in the selected high expansion aqueous foam. The phase three objectives were to build a prototype individual cell aqueous foam system and to study the feasibility of aqueous foams for large prison facility disturbances. The phase four and five objectives were to use the prototype system to do large scale foam physical characteristics testing of the selected foam concentrate, and to have the prototype single cell system further evaluated by correctional representatives. Prison rather than street scenarios were evaluated as the first and most likely place for using the aqueous foam since prisons have recurrent incidents where officers and inmates might be seriously injured during violent confrontations. The very low density of the high expansion foam also makes it more suitable for indoor use. This paper summarizes the results of the project.

  17. EXPLORING THE BIOTRANSFORMATION POTENTIAL OF FLUOROTELOMER ALCOHOL-BASED POLYMER FORMULATIONS DURING AEROBIC BIOLOGICAL WASTEWATER TREATMENT

    EPA Science Inventory

    Fluorotelomer alcohols have been widely used over the past 50 years in surface protection products for paper, packaging, textile, and carpet goods; in industrial surfactant mixtures; in aqueous fire-fighting foams, and as processing aids during the production of fluoropolymer pla...

  18. 46 CFR Appendix B to Subpart C of... - Substance Technical Guidelines, Benzene

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Subpart C of Part 197—Substance Technical Guidelines, Benzene I. Physical and Chemical Data (a) Substance...) Extinguishing media: Carbon dioxide, dry chemical, or foam. (5) Special fire fighting procedures: Do not use a... engineering). (b) Reactivity. (1) Conditions contributing to instability: Heat. (2) Incompatibility: Heat and...

  19. 20. HANGAR BAY #2 FORWARD LOOKING AFT ON CENTERLINE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    20. HANGAR BAY #2 - FORWARD LOOKING AFT ON CENTERLINE - STARBOARD SIDE SHOWING CONFLAGRATION STATION, UPTAKE SPACE AND DEHUMIDIFICATION MACHINES - PORT SIDE SHOWING VARIOUS DECK WINCHES, ROLLER DOORS, HANGAR DECK PLANE CONTROL STATION AND AQUEOUS FIRE FIGHTING FOAM HOSE REELS. - U.S.S. HORNET, Puget Sound Naval Shipyard, Sinclair Inlet, Bremerton, Kitsap County, WA

  20. Effects of Three Fire-Suppressant Foams on the Germination and Physiological Responses of Plants

    NASA Astrophysics Data System (ADS)

    Song, Uhram; Mun, Saeromi; Waldman, Bruce; Lee, Eun Ju

    2014-10-01

    Suppressant foams used to fight forest fires may leave residual effects on surviving biota that managers need to consider prior to using them. We examined how three fire-suppressant foams (FSFs) (Forexpan S, Phos-Chek-WD881, and Silv-ex) affected seed germination and physiological responses of three plant species. Exposure to FSFs, whether in diluted concentrations or those typical in the field, reduced final germination percentages of seeds grown in petri dishes and within growth chambers. However, the FSFs did not cause total germination failure in any treatment. Inhibition of germination increased with longer exposure times, but only to diluted FSF solutions. Unlike in the laboratory experiments, none of the three FSFs affected seedling emergence when tested in field conditions. Further, we found no evidence of long-term phytotoxic effects on antioxidant enzyme activity nor chlorophyll content of the plant saplings. Therefore, although the three FSFs showed evidence of phytotoxicity to plants in laboratory tests, their actual impact on terrestrial ecosystems may be minimal. We suggest that the benefits of using these FSFs to protect plants in threatened forest ecosystems outweigh their minor risks.

  1. Effects of three fire-suppressant foams on the germination and physiological responses of plants.

    PubMed

    Song, Uhram; Mun, Saeromi; Waldman, Bruce; Lee, Eun Ju

    2014-10-01

    Suppressant foams used to fight forest fires may leave residual effects on surviving biota that managers need to consider prior to using them. We examined how three fire-suppressant foams (FSFs) (Forexpan S, Phos-Chek-WD881, and Silv-ex) affected seed germination and physiological responses of three plant species. Exposure to FSFs, whether in diluted concentrations or those typical in the field, reduced final germination percentages of seeds grown in petri dishes and within growth chambers. However, the FSFs did not cause total germination failure in any treatment. Inhibition of germination increased with longer exposure times, but only to diluted FSF solutions. Unlike in the laboratory experiments, none of the three FSFs affected seedling emergence when tested in field conditions. Further, we found no evidence of long-term phytotoxic effects on antioxidant enzyme activity nor chlorophyll content of the plant saplings. Therefore, although the three FSFs showed evidence of phytotoxicity to plants in laboratory tests, their actual impact on terrestrial ecosystems may be minimal. We suggest that the benefits of using these FSFs to protect plants in threatened forest ecosystems outweigh their minor risks.

  2. Biogeochemical assessment of natural attenuation of JP-4-contaminated ground water in the presence of fluorinated surfactants.

    PubMed

    Levine, A D; Libelo, E L; Bugna, G; Shelley, T; Mayfield, H; Stauffer, T B

    1997-12-22

    The biogeochemistry of the natural attenuation of petroleum-contaminated ground water was investigated in a field study. The focus of the study was a fire training site located on Tyndall Air Force Base in Florida. The site has been used by the Air Force for approximately 11 years in fire fighting exercises. An on-site above-ground tank of JP-4 provided fuel for setting controlled fires for the exercises. Various amounts of water and aqueous film forming foams (AFFF) were applied to extinguish the fires. The sources of contamination included leaks from pipelines transporting the fuel, leaks from an oil/water separator and runoff and percolation from the fire fighting activities. Previous investigations had identified jet fuel contamination at the site, however, no active remediation efforts have been conducted to date. The goal of this study was to use biogeochemical monitoring data to delineate redox zones within the site and to identify evidence of natural attenuation of JP-4 contamination. In addition to identifying several hydrocarbon metabolites, fluorinated surfactants (AFFF) were detected down-gradient of the hydrocarbon plume.

  3. Aviation Engine Test Facilities (AETF) fire protection study

    NASA Astrophysics Data System (ADS)

    Beller, R. C.; Burns, R. E.; Leonard, J. T.

    1989-07-01

    An analysis is presented to the effectiveness of various types of fire fighting agents in extinguishing the kinds of fires anticipated in Aviation Engine Test Facilities (AETF), otherwise known as Hush Houses. The agents considered include Aqueous Film-Forming Foam, Halon 1301, Halon 1211 and water. Previous test work has shown the rapidity with which aircraft, especially high performance aircraft, can be damaged by fire. Based on this, tentative criteria for this evaluation included a maximum time of 20 s from fire detection to extinguishment and a period of 30 min in which the agent would prevent reignition. Other issues examined included: toxicity, corrosivity, ease of personnel egress, system reliability, and cost effectiveness. The agents were evaluated for their performance in several fire scenarios, including: under frame fire, major engine fire, engine disintegration fire, high-volume pool fire with simultaneous spill fire, internal electrical fire, and runaway engine fire.

  4. Controlling wildlife fungal disease spread: in vitro efficacy of disinfectants against Batrachochytrium dendrobatidis and Mucor amphibiorum.

    PubMed

    Webb, Rebecca; Philips, Annie; Speare, Rick; Connolly, Joanne; Berger, Lee

    2012-06-13

    Chytridiomycosis in amphibians, and mucormycosis in the platypus Ornithorhynchus anatinus and amphibians, are serious fungal diseases affecting these aquatic taxa. In Tasmania, Australia, the fungi that cause these diseases overlap in range along with Phytophthora cinnamomi (Pc), an invasive fungal plant pathogen. To identify disinfectants that may be useful to reduce anthropogenic spread of these fungi to uninfected wilderness areas, for example by bush walkers and forestry or fire-fighting operations, we tested 3 disinfectants and a fire-fighting foam against Mucor amphibiorum (Ma) and tested 1 disinfectant and the foam against Batrachochytrium dendrobatidis (Bd). Combining the present study with previous work we found Bd was more susceptible to all 4 chemicals than Ma. Phytoclean, a disinfectant used at 2 to 10% for 30 s to control Pc, killed cultures of Bd at 0.075% and Ma at 5%, when also applied for 30 s. The disinfectant F10sc was not effective against Ma at standard exposures, but previous work shows Bd is killed at 0.03% with a 1 min exposure. Path-X is effective against Bd at 0.001% with a 30 s exposure and killed Ma at 1% with a 5 min exposure. Forexpan S, a foam added to water at 0.1 to 1% to control forest fires, killed Bd but not Ma when used at 1% for 2 min. Therefore, Phytoclean and Path-X have broader efficacy, although Path-X has not been trialled against Pc. Interestingly a positive mating strain of Ma (from a platypus) was more resistant to disinfectants than a negative strain (from a frog). Current protocols against Pc that involve high concentrations (10%) of Phytoclean are likely to reduce spread of pathogenic wildlife fungi, which is important for protecting biodiversity.

  5. Acute toxicity of fire-retardant and foam-suppressant chemicals to yalella azteca (Saussure)

    USGS Publications Warehouse

    McDonald, Susan F.; Hamilton, Steven J.; Buhl, Kevin J.; Heisinger, James F.

    1997-01-01

    Acute toxicity tests were conducted with Hyalella azteca Saussure (an amphipod) exposed in soft and hard waters to three fire retardants (Fire-Trol GTS-R, Fire-Trol LCG-R, and Phos-Chek D75-F) and two foam suppressants (Phos-Chek WD-881 and Silv-Ex). The chemicals were slightly to moderately toxic to amphipods. The most toxic chemical to amphipods in soft and hard water was Phos-Chek WD-881 (96-h mean lethal concentration [LC50] equal to 10 mg/L and 22 mg/L, respectively), and the least toxic chemical to amphipods in soft water was Fire-Trol GTS-R (96-h LC50 equal to 127 mg/L) and in hard water was Fire-Trol LCG-R (96-h LC50 equal to 535 mg/L). Concentrations of ammonia in tests with the three fire retardants and both water types were greater than reported LC50 values and probably were the major toxic component. Estimated un-ionized ammonia concentrations near the LC50 were frequently less than the reported LC50 ammonia concentrations for amphipods. The three fire retardants were more toxic in soft water than in hard water even though ammonia and un-ionized ammonia concentrations were higher in hard water tests than in soft water tests. The accidental entry of fire-fighting chemicals into aquatic environments could adversely affect aquatic invertebrates, thereby disrupting ecosystem function.

  6. Identification of the source of PFOS and PFOA contamination at a military air base site.

    PubMed

    Arias E, Victor A; Mallavarapu, Megharaj; Naidu, Ravi

    2015-01-01

    Although the use of perfluorooctane sulfonic acid (PFOS)/perfluorooctanoic acid (PFOA)-based aqueous fire-fighting foams (AFFF) has been banned due to their persistence, bioaccumulation and toxicity to biota, PFOS and PFOA are still present at significant levels in the environment due to their past usage. This study investigated the reasons for detection of PFOS and PFOA in an evaporation pond used to collect the wastewater arising from fire-fighting exercises at a military air base despite the replacement of PFOS/PFOA-based foam with no PFOS/PFOA-foam about 6 years ago. Concentrations in the wastewater stored in this pond ranged from 3.6 to 9.7 mg/L for PFOS and between 0.6 and 1.7 mg/L for PFOA. The hypothesis tested in a laboratory study was that PFOS and PFOA have accumulated in the sediments of the pond and can be released into the main body of the water. Concentrations detected in the sediments were 38 and 0.3 mg/g for PFOS and PFOA, respectively. These values exceed the recently reported average global values for sediments (0.2-3.8 ng/g for PFOS and from 0.1 to 0.6 ng/g for PFOA) by a factor of several thousands. PFOS and PFOA distribution coefficients were derived for the organic content of the pond sediment (1.6%). Identification of the source of contamination and knowledge of the partition between soil and aqueous phases are vital first steps in developing a sustainable remediation technology to remove the source from the site. This study clearly suggests that unless the sediment is cleaned of PFOS/PFOA, these chemicals will continue to be detected for a long period in the pond water, with potential adverse impacts on the ecosystem.

  7. Efficient removal of perfluorooctane sulfonate from aqueous film-forming foam solution by aeration-foam collection.

    PubMed

    Meng, Pingping; Deng, Shubo; Maimaiti, Ayiguli; Wang, Bin; Huang, Jun; Wang, Yujue; Cousins, Ian T; Yu, Gang

    2018-07-01

    Aqueous film-forming foams (AFFFs) used in fire-fighting are one of the main contamination sources of perfluorooctane sulfonate (PFOS) to the subterranean environment, requiring high costs for remediation. In this study, a method that combined aeration and foam collection was presented to remove PFOS from a commercially available AFFF solution. The method utilized the strong surfactant properties of PFOS that cause it to be highly enriched at air-water interfaces. With an aeration flow rate of 75 mL/min, PFOS removal percent reached 96% after 2 h, and the PFOS concentration in the collected foam was up to 6.5 mmol/L, beneficial for PFOS recovery and reuse. Increasing the aeration flow rate, ionic strength and concentration of co-existing surfactant, as well as decreasing the initial PFOS concentration, increased the removal percents of PFOS by increasing the foam volume, but reduced the enrichment of PFOS in the foams. With the assistance of a co-existing hydrocarbon surfactant, PFOS removal percent was above 99.9% after aeration-foam collection for 2 h and the enrichment factor exceeded 8400. Aeration-foam collection was less effective for short-chain perfluoroalkyl substances due to their relatively lower surface activity. Aeration-foam collection was found to be effective for the removal of high concentrations of PFOS from AFFF-contaminated wastewater, and the concentrated PFOS in the collected foam can be reused. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. PPAR-α, a lipid-sensing transcription factor, regulates blood–brain barrier efflux transporter expression

    PubMed Central

    More, Vijay R; Campos, Christopher R; Evans, Rebecca A; Oliver, Keith D; Chan, Gary NY; Miller, David S

    2016-01-01

    Lipid sensor peroxisome proliferator-activated receptor alpha (PPAR-α) is the master regulator of lipid metabolism. Dietary release of endogenous free fatty acids, fibrates, and certain persistent environmental pollutants, e.g. perfluoroalkyl fire-fighting foam components, are peroxisome proliferator-activated receptor alpha ligands. Here, we define a role for peroxisome proliferator-activated receptor alpha in regulating the expression of three ATP-driven drug efflux transporters at the rat and mouse blood–brain barriers: P-glycoprotein (Abcb1), breast cancer resistance protein (Bcrp/Abcg2), and multidrug resistance-associated protein 2 (Mrp2/Abcc2). Exposing isolated rat brain capillaries to linoleic acid, clofibrate, or PKAs increased the transport activity and protein expression of the three ABC transporters. These effects were blocked by the PPAR-α antagonist, GW6471. Dosing rats with 20 mg/kg or 200 mg/kg of clofibrate decreased the brain accumulation of the P-glycoprotein substrate, verapamil, by 50% (in situ brain perfusion; effects blocked by GW6471) and increased P-glycoprotein expression and activity in capillaries ex vivo. Fasting C57Bl/6 wild-type mice for 24 h increased both serum lipids and brain capillary P-glycoprotein transport activity. Fasting did not alter P-glycoprotein activity in PPAR-α knockout mice. These results indicate that hyperlipidemia, lipid-lowering fibrates and exposure to certain fire-fighting foam components activate blood–brain barrier peroxisome proliferator-activated receptor alpha, increase drug efflux transporter expression and reduce drug delivery to the brain. PMID:27193034

  9. Evaluation of the diving reflex in response to nonterminal submersion of White Pekin ducks in water-based foam.

    PubMed

    Caputo, M P; Alphin, R L; Pritchett, E; Hougentogler, D P; Johnson, A L; Benson, E R; Patil, C

    2013-02-01

    The mass depopulation of production birds remains an effective means of controlling fast-moving, highly infectious diseases such as avian influenza and virulent Newcastle disease. Water-based fire-fighting foam is a conditionally approved method of depopulating floor-reared gallinaceous poultry such as chickens and turkeys; however, ducks have physiological mechanisms that may make them more resistant to this method of depopulation. The following experiment was designed to assess the physiological responses of White Pekin ducks to nonterminal submersion in water-based foam compared with water. The hypothesis of this experiment was that submersion of ducks in water or water-based foam would trigger the diving reflex and lead to bradycardia. All treatments led to pronounced bradycardia. Heart rate was not significantly different between treatments during the final 30 s of the 60-s treatment period. Heart rate dropped significantly faster for the water dip and foam dip treatments and rose significantly faster than the foam pour treatment after the termination of the 60-s treatment period. Duration of bradycardia approached significance for the foam pour treatment, leading to a longer duration of bradycardia compared with the water pour, water dip, and foam dip treatments. The results of this experiment demonstrated that apnea and bradycardia as a result of the diving reflex can occur as a result of submersion in foam, which may have an impact on the time it takes White Pekin ducks to reach unconsciousness and death during water-based foam depopulation.

  10. Coal Field Fire Fighting - Practiced methods, strategies and tactics

    NASA Astrophysics Data System (ADS)

    Wündrich, T.; Korten, A. A.; Barth, U. H.

    2009-04-01

    Subsurface coal fires destroy millions of tons of coal each year, have an immense impact to the ecological surrounding and threaten further coal reservoirs. Due to enormous dimensions a coal seam fire can develop, high operational expenses are needed. As part of the Sino-German coal fire research initiative "Innovative technologies for exploration, extinction and monitoring of coal fires in Northern China" the research team of University of Wuppertal (BUW) focuses on fire extinction strategies and tactics as well as aspects of environmental and health safety. Besides the choice and the correct application of different extinction techniques further factors are essential for the successful extinction. Appropriate tactics, well trained and protected personnel and the choice of the best fitting extinguishing agents are necessary for the successful extinction of a coal seam fire. The chosen strategy for an extinction campaign is generally determined by urgency and importance. It may depend on national objectives and concepts of coal conservation, on environmental protection (e.g. commitment to green house gases (GHG) reductions), national funding and resources for fire fighting (e.g. personnel, infrastructure, vehicles, water pipelines); and computer-aided models and simulations of coal fire development from self ignition to extinction. In order to devise an optimal fire fighting strategy, "aims of protection" have to be defined in a first step. These may be: - directly affected coal seams; - neighboring seams and coalfields; - GHG emissions into the atmosphere; - Returns on investments (costs of fire fighting compared to value of saved coal). In a further step, it is imperative to decide whether the budget shall define the results, or the results define the budget; i.e. whether there are fixed objectives for the mission that will dictate the overall budget, or whether the limited resources available shall set the scope within which the best possible results shall be achieved. For an effective and efficient fire fighting optimal tactics are requiered and can be divided into four fundamental tactics to control fire hazards: - Defense (digging away the coal, so that the coal can not begin to burn; or forming a barrier, so that the fire can not reach the not burning coal), - Rescue the coal (coal mining of a not burning seam), - Attack (active and direct cooling of burning seam), - Retreat (only monitoring till self-extinction of a burning seam). The last one is used when a fire exceeds the organizational and/or technical scope of a mission. In other words, "to control a coal fire" does not automatically and in all situations mean "to extinguish a coal fire". Best-practice tactics or a combination of them can be selected for control of a particular coal fire. For the extinguishing works different extinguishing agents are available. They can be applied by different application techniques and varying distinctive operating expenses. One application method may be the drilling of boreholes from the surface or covering the surface with low permeability soils. The mainly used extinction agents for coal field fire are as followed: Water (with or without additives), Slurry, Foaming mud/slurry, Inert gases, Dry chemicals and materials and Cryogenic agents. Because of its tremendous dimension and its complexity the worldwide challenge of coal fires is absolutely unique - it can only be solved with functional application methods, best fitting strategies and tactics, organisation and research as well as the dedication of the involved fire fighters, who work under extreme individual risks on the burning coal fields.

  11. 46 CFR 35.40-10 - Steam, foam, or CO2 fire smothering apparatus-TB/ALL.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Steam, foam, or CO2 fire smothering apparatus-TB/ALL. 35... Posting and Marking Requirements-TB/ALL. § 35.40-10 Steam, foam, or CO2 fire smothering apparatus—TB/ALL. Steam, foam, or CO2 fire smothering apparatus shall be marked “STEAM FIRE APPARATUS” or “FOAM FIRE...

  12. 46 CFR 35.40-10 - Steam, foam, or CO2 fire smothering apparatus-TB/ALL.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 1 2011-10-01 2011-10-01 false Steam, foam, or CO2 fire smothering apparatus-TB/ALL. 35... Posting and Marking Requirements-TB/ALL. § 35.40-10 Steam, foam, or CO2 fire smothering apparatus—TB/ALL. Steam, foam, or CO2 fire smothering apparatus shall be marked “STEAM FIRE APPARATUS” or “FOAM FIRE...

  13. Effects of fire and three fire-fighting chemicals on main soil properties, plant nutrient content and vegetation growth and cover after 10 years.

    PubMed

    Fernández-Fernández, M; Gómez-Rey, M X; González-Prieto, S J

    2015-05-15

    The study addresses a knowledge-gap in the long-term ecological consequences of fire and fire-fighting chemicals. Ten years after a prescribed fire and the application of three fire-fighting chemicals, their effects on the soil-plant system were evaluated. Five treatments were established: unburnt soils (US) and burnt soils treated with water alone (BS), foaming agent (BS+Fo), Firesorb (BS+Fi) and ammonium polyphosphate (BS+Ap). Soils (0-2 cm depth) and foliar material of shrubs (Erica umbellata, Pterospartum tridentatum and Ulex micranthus) and trees (Pinus pinaster) were analysed for total N, δ(15)N, and soil-available and plant total macronutrients and trace elements. Soil pH, NH₄(+)-N and NO₃(-)-N; pine basal diameter and height; and shrub cover and height were also measured. Compared with US plots, burnt soils had less nitrates and more Mo. Although differences were not always significant, BS+Ap had the highest levels of soil available P, Na and Al. Plants from BS+Ap plots had higher values of δ(15)N (P. pinaster and E. umbellata), P (all species), Na (P. tridentatum and U. micranthus) and Mg (E. umbellata and P. tridentatum) than other treatments; while K in plants from BS+Ap plots was the highest among treatments for P. pinaster and the lowest for the shrubs. Pines in US plots were higher and wider than in burnt treatments, except for BS+Ap, where the tallest and widest trees were found, although half of them were either dead (the second highest mortality after BS+Fi) or had a distorted trunk. BS+Ap was the treatment with strongest effects on plants, showing E. umbellata the lowest coverage and height, P. tridentatum the highest coverage, U. micranthus one of the lowest coverages and being the only treatment where Genista triacanthos was absent. Consequently, it is concluded that both fire and ammonium polyphosphate application had significant effects on the soil-plant system after 10 years. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Foam composite structures. [for fire retardant airframe materials

    NASA Technical Reports Server (NTRS)

    Delano, C. B.; Milligan, R. J.

    1976-01-01

    The need to include fire resistant foams into state of the art aircraft interior paneling to increase passenger safety in aircraft fires was studied. Present efforts were directed toward mechanical and fire testing of panels with foam inclusions. Skinned foam filled honeycomb and PBI structural foams were the two constructions investigated with attention being directed toward weight/performance/cost trade-off. All of the new panels demonstrated improved performance in fire and some were lighter weight but not as strong as the presently used paneling. Continued efforts should result in improved paneling for passenger safety. In particular the simple partial filling (fire side) of state-of-the-art honeycomb with fire resistant foams with little sacrifice in weight would result in panels with increased fire resistance. More important may be the retarded rate of toxic gas evolution in the fire due to the protection of the honeycomb by the foam.

  15. Foam as a Fire Suppressant: An Evaluation

    Treesearch

    Paul Schlobohm; Ron Rochna

    1987-01-01

    The ability of fire suppressant foams to improve ground-applied fire control efforts was evaluated. Foaming agents and foam-generating systems were examined. Performance evaluations were made for direct attack, indirect attack, and mop-up. Foam was determined to suppress and repel fire in situations where water did not. Cost comparisons of mop-up work showed straight...

  16. 75 FR 221 - Airworthiness Directives; Fire Fighting Enterprises Limited Portable Halon 1211 Fire...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-05

    ... Airworthiness Directives; Fire Fighting Enterprises Limited Portable Halon 1211 Fire Extinguishers as Installed... specification, have been supplied to the aviation industry for use in fire extinguishing equipment. * * * * * * * * * * * This Halon 1211 has subsequently been used to fill certain FFE [Fire Fighting Enterprises] portable...

  17. Occurrence of perfluoroalkyl sulfonates and carboxylates in German drinking water sources compared to other countries.

    PubMed

    Lange, F T; Wenz, M; Schmidt, C K; Brauch, H-J

    2007-01-01

    Different homologues of C4 to C8 perfluoroalkyl carboxylates (PFCAs) and perfluoroalkyl sulfonates (PFASs) were detected in German surface waters, bank filtrates, artificially recharged groundwaters, and drinking waters. If no point sources are located nearby, the typically measured levels are in the low ng/L range. In the presence of point sources, such as a fluorochemical production site, a leaching agricultural fertilizer contaminated with PFCAs and PFASs, or drained PFC containing fire-fighting foams, much higher concentrations in the microg/L range occur. This situation is similar in Germany and other countries.

  18. A STUDY ON A COOPERATIVE RELATIONSHIP TO THE IMPROVEMENT OF THE REGIONAL FIRE FIGHTING VALIDITY -Case Study in Bangkok, Thailand-

    NASA Astrophysics Data System (ADS)

    Sripramai, Keerati; Oikawa, Yasushi; Watanabe, Hiroshi; Katada, Toshitaka

    Generally, in order to improve some regional fire fighting validity, indispensable strategies are not only a reinforcement of the governmental fire fighting ability, but also a strengthening of the cooperative relationship between governmental and non-governmental fire fighting ability. However, for practical purposes, the effective strategy should be different depending on the actual situationin the subject area. So, in this study, we grasp the actual state and background of the problems that need to be solved for the improvement of the regional fire fighting validity in Bangkok as a case study, and examine the appropriate solution focusing on the relationship between official and voluntary fire fighting. Through some practicable activities such as interviews, investigati ons, and making the regional fire fighting validity map, it became clear that the problems of uncooperative relationship and the lack of trust between stakeholders should be solved first and foremost.

  19. 46 CFR 167.45-30 - Use of approved fire-fighting equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... PUBLIC NAUTICAL SCHOOL SHIPS Special Firefighting and Fire Prevention Requirements § 167.45-30 Use of approved fire-fighting equipment. Portable fire extinguishers or fire-extinguishing systems which conform... 46 Shipping 7 2010-10-01 2010-10-01 false Use of approved fire-fighting equipment. 167.45-30...

  20. Ecotoxicity of waste water from industrial fires fighting

    NASA Astrophysics Data System (ADS)

    Dobes, P.; Danihelka, P.; Janickova, S.; Marek, J.; Bernatikova, S.; Suchankova, J.; Baudisova, B.; Sikorova, L.; Soldan, P.

    2012-04-01

    As shown at several case studies, waste waters from extinguishing of industrial fires involving hazardous chemicals could be serious threat primary for surrounding environmental compartments (e.g. surface water, underground water, soil) and secondary for human beings, animals and plants. The negative impacts of the fire waters on the environment attracted public attention since the chemical accident in the Sandoz (Schweizerhalle) in November 1986 and this process continues. Last October, special Seminary on this topic has been organized by UNECE in Bonn. Mode of interaction of fire waters with the environment and potential transport mechanisms are still discussed. However, in many cases waste water polluted by extinguishing foam (always with high COD values), flammable or toxic dangerous substances as heavy metals, pesticides or POPs, are released to surface water or soil without proper decontamination, which can lead to environmental accident. For better understanding of this type of hazard and better coordination of firemen brigades and other responders, the ecotoxicity of such type of waste water should be evaluated in both laboratory tests and in water samples collected during real cases of industrial fires. Case studies, theoretical analysis of problem and toxicity tests on laboratory model samples (e.g. on bacteria, mustard seeds, daphnia and fishes) will provide additional necessary information. Preliminary analysis of waters from industrial fires (polymer material storage and galvanic plating facility) in the Czech Republic has already confirmed high toxicity. In first case the toxicity may be attributed to decomposition of burned material and extinguishing foams, in the latter case it can be related to cyanides in original electroplating baths. On the beginning of the year 2012, two years R&D project focused on reduction of extinguish waste water risk for the environment, was approved by Technology Agency of the Czech Republic.

  1. Initial Evaluation of Burn Characteristics of Phenolic Foam Runway Brake Arrestor Material

    DTIC Science & Technology

    1993-12-01

    foam immersed in a jet fuel fire when extinguished using 3-percent Aqueous Film Forming Foam ( AFFF ). Three pool...extinguishment time of phenolic foam immersed in a jet fuel fire, using 3-percent Aqueous Film Forming Foam ( AFFF ) extinguishing agent. The wind was negligible...percent Aqueous Film Forming Foam ( AFFF ) agent. This project is an initial assessment of the fire safety of phenolic foam

  2. Fire-Retardant, Self-Extinguishing Inorganic/Polymer Composite Memory Foams.

    PubMed

    Chatterjee, Soumyajyoti; Shanmuganathan, Kadhiravan; Kumaraswamy, Guruswamy

    2017-12-27

    Polymeric foams used in furniture and automotive and aircraft seating applications rely on the incorporation of environmentally hazardous fire-retardant additives to meet fire safety norms. This has occasioned significant interest in novel approaches to the elimination of fire-retardant additives. Foams based on polymer nanocomposites or based on fire-retardant coatings show compromised mechanical performance and require additional processing steps. Here, we demonstrate a one-step preparation of a fire-retardant ice-templated inorganic/polymer hybrid that does not incorporate fire-retardant additives. The hybrid foams exhibit excellent mechanical properties. They are elastic to large compressional strain, despite the high inorganic content. They also exhibit tunable mechanical recovery, including viscoelastic "memory". These hybrid foams are prepared using ice-templating that relies on a green solvent, water, as a porogen. Because these foams are predominantly comprised of inorganic components, they exhibit exceptional fire retardance in torch burn tests and are self-extinguishing. After being subjected to a flame, the foam retains its porous structure and does not drip or collapse. In micro-combustion calorimetry, the hybrid foams show a peak heat release rate that is only 25% that of a commercial fire-retardant polyurethanes. Finally, we demonstrate that we can use ice-templating to prepare hybrid foams with different inorganic colloids, including cheap commercial materials. We also demonstrate that ice-templating is amenable to scale up, without loss of mechanical performance or fire-retardant properties.

  3. Acute toxicity of fire control chemicals to Daphnia magna(Straus) and Selenastrum capricornutum(Printz)

    USGS Publications Warehouse

    McDonald, Susan F.; Hamilton, Steven J.; Buhl, Kevin J.; Heisinger, James F.

    1996-01-01

    Acute toxicity tests were conducted exposingDaphnia magnaStraus (daphnid) in soft and hard reconstituted waters (hardness 42 and 162 mg/liter as CaCO3, respectively), andSelenastrum capricornutumPrintz (algae) in ASTM algal assay medium (hardness 15 mg/liter as CaCO3) to fire retardants Fire-Trol GTS-R, Fire-Trol LCG-R, and Phos-Chek D75-F, and foam suppressants Phos-Chek WD-881 and Silv-Ex. The chemicals were slightly toxic to practically harmless to daphnids and moderately toxic to algae. Water quality did not consistently alter the toxicity of the test chemicals to daphnids. The most toxic chemical to daphnids was Silv-Ex (48-hr EC507 mg/liter in soft and hard waters), whereas the least toxic chemical to daphnids was Fire-Trol LCG-R (48-hr EC50848 mg/liter in soft water, 813 mg/liter in hard water). The most toxic chemical to algae was Fire-Trol LCG-R (96-hr IC5010 mg/liter), and the least toxic chemical was Phos-Chek D75-F (96-hr IC5079 mg/liter). Un-ionized ammonia concentrations near the EC50or IC50value in tests with the Fire-Trol compounds were frequently equal to or above reported LC50un-ionized ammonia concentrations. Un-ionized ammonia concentrations in tests with Phos-Chek D75-F were low, thus other toxic components present in the compounds probably contributed to the toxicity. When compared to the daphnids tested in ASTM soft water, the Fire-Trol compounds were most toxic to algae, whereas Phos-Chek D75-F and the foam suppressants were most toxic to daphnids. The results of these tests are comparable to those obtained from research conducted in other laboratories with the same species and similar chemicals. Accidental entry of fire-fighting chemicals into aquatic environments could adversely affect algae and aquatic invertebrates, thus disrupting ecosystem function.

  4. Experimental investigation on temperature distribution of foamed concrete filled steel tube column under standard fire

    NASA Astrophysics Data System (ADS)

    Kado, B.; Mohammad, S.; Lee, Y. H.; Shek, P. N.; Kadir, M. A. A.

    2018-04-01

    Standard fire test was carried out on 3 hollow steel tube and 6 foamed concrete filled steel tube columns. Temperature distribution on the columns was investigated. 1500 kg/m3 and 1800 kg/m3 foamed concrete density at 15%, 20% and 25% load level are the parameters considered. The columns investigated were 2400 mm long, 139.7 mm outer diameter and 6 mm steel tube thickness. The result shows that foamed concrete filled steel tube columns has the highest fire resistance of 43 minutes at 15% load level and low critical temperature of 671 ºC at 25% load level using 1500 kg/m3 foamed concrete density. Fire resistance of foamed concrete filled column increases with lower foamed concrete strength. Foamed concrete can be used to provide more fire resistance to hollow steel column or to replace normal weight concrete in concrete filled columns. Since filling hollow steel with foamed concrete produce column with high fire resistance than unfilled hollow steel column. Therefore normal weight concrete can be substituted with foamed concrete in concrete filled column, it will reduces the self-weight of the structure because of its light weight at the same time providing the desired fire resistance.

  5. Stockholm Arlanda Airport as a source of per- and polyfluoroalkyl substances to water, sediment and fish.

    PubMed

    Ahrens, Lutz; Norström, Karin; Viktor, Tomas; Cousins, Anna Palm; Josefsson, Sarah

    2015-06-01

    Fire training facilities are potential sources of per- and polyfluoroalkyl substances (PFASs) to the nearby environment due to the usage of PFAS-containing aqueous fire-fighting foams (AFFFs). The multimedia distribution of perfluoroalkyl carboxylates (PFCAs), perfluoroalkyl sulfonates (PFSAs), perfluorooctanesulfonamide (PFOSA) and 6:2 fluorotelomer sulfonate (FTSA) was investigated near a fire training facility at Stockholm Arlanda Airport in Sweden. The whole body burden of PFASs in European perch (Perca fluviatilis) was 334±80μg absolute and was distributed as follows: Gonad>liver≈muscle>blood>gill. The bioconcentration factor (BCF) and sediment/water partition coefficient (Kd) increased by 0.6-1.7 and 0.2-0.5 log units, respectively, for each additional CF2 moiety for PFCAs and PFSAs. PFAS concentrations in water showed no significant decreasing trend between 2009 and 2013 (p>0.05), which indicates that Stockholm Arlanda Airport may be an important source for long-term contamination of the nearby environment with PFASs. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. 14 CFR 121.106 - ETOPS Alternate Airport: Rescue and fire fighting service.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... augmented to meet paragraph (a) of this section from local fire fighting assets. A 30-minute response time... fighting service. 121.106 Section 121.106 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT... and Flag Operations § 121.106 ETOPS Alternate Airport: Rescue and fire fighting service. (a) Except as...

  7. 14 CFR 121.106 - ETOPS Alternate Airport: Rescue and fire fighting service.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... augmented to meet paragraph (a) of this section from local fire fighting assets. A 30-minute response time... fighting service. 121.106 Section 121.106 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT... and Flag Operations § 121.106 ETOPS Alternate Airport: Rescue and fire fighting service. (a) Except as...

  8. Fire retardant foams developed to suppress fuel fires

    NASA Technical Reports Server (NTRS)

    Fish, R.; Gilwee, W. J.; Parker, J. A.; Riccitiello, S. R.

    1968-01-01

    Heat insulating polyurethane foam retards and suppresses fuel fires. Uniformly dispersed in the foam is a halogenated polymer capable of splitting off hydrogen halide upon heating and charring of the polyurethane.

  9. The search for alternative aqueous film forming foams (AFFF) with a low environmental impact: physiological and transcriptomic effects of two Forafac(®) fluorosurfactants in turbot.

    PubMed

    Hagenaars, A; Meyer, I J; Herzke, D; Pardo, B G; Martinez, P; Pabon, M; De Coen, W; Knapen, D

    2011-08-01

    Fluorosurfactants are the key components in aqueous film forming foams (AFFF). They provide these fire fighting agents with the required low surface tension and they enable film formation on top of lighter fuels to prevent burn back. Development of effective and environmentally acceptable PFOS alternatives is one of the most important priorities in the fire fighting foam industry. DuPont™ offers the fluorosurfactant mixtures Forafac(®)1157 and Forafac(®)1157N for the formulation of AFFFs which are alternatives to the persistent and toxic perfluorooctane sulphonate (PFOS). Ecotoxicological testing of these inadequately documented mixtures is necessary to include them in AFFF hazard and risk assessment. Juvenile turbot (Scophthalmus maximus) were exposed for 14 days to 0.1; 0.5 and 1.5mg/L of the fluorosurfactant mixtures used in Forafac(®)1157 and Forafac(®)1157N. In an initial transcriptomics experiment, microarray analysis revealed differentially expressed transcripts of genes which were mainly involved in digestion and in the immune system. This discovery-driven screening approach offered the basis for new hypotheses that were tested in two subsequent experiments in which food intake, energy reserves, growth and a set of haematological parameters were examined. Additionally, effects of the two mixtures were compared to those of PFOS. Based on the results of this study, the mode of action of Forafac(®)1157N was the activation of the acute phase reaction resulting in increased leukocyte concentrations and the inhibition of growth due to the high energetic cost of toxicant exposure. For Forafac(®)1157, evidences of immunosuppression were found on the transcriptional level and the altered differential leukocyte profiles indicated that stress was induced in these fish. However, food intake, energy reserves and growth were not compromised, even at high exposure concentrations, which was in contrast to the effects seen after PFOS exposure. Taking into account that Forafac(®)1157 appeared to be less toxic than PFOS, this mixture could be considered as a more environmentally acceptable PFOS alternative for the use in AFFFs. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Comparative Evaluation of Firefighting Foam Agents

    DTIC Science & Technology

    1979-08-01

    incorporating these basic concepts under a military specification, are being produced on a world-wide MIL - F - 24385 , Navy (reference 6). basis. The original...Program Office for 24385 (Navy), Fire Extinguishing Aircraft Ground Fire Suppression and Agent, Aqueous- F Ilm-Forming-Foam Rescue, SMF, AGFSkS 71-1...fluoroprotein foams (FPF), and three protein foam (?’ F ) agents. Large-scale fire tests were performed under fixed fire conditions employing air

  11. 46 CFR 167.55-5 - Marking of fire and emergency equipment.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    .../2-inch red letters: “General Alarm—When Bell Rings Go to Your Station.” (c) Steam, foam or CO 2 fire smothering apparatus. Steam, foam or CO2 fire smothering apparatus shall be marked “Steam Fire Apparatus” or “Foam Fire Apparatus” or “CO2 Fire Apparatus”, as appropriate, in not less than 2-inch red letters. The...

  12. 46 CFR 167.55-5 - Marking of fire and emergency equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    .../2-inch red letters: “General Alarm—When Bell Rings Go to Your Station.” (c) Steam, foam or CO 2 fire smothering apparatus. Steam, foam or CO2 fire smothering apparatus shall be marked “Steam Fire Apparatus” or “Foam Fire Apparatus” or “CO2 Fire Apparatus”, as appropriate, in not less than 2-inch red letters. The...

  13. 46 CFR 167.55-5 - Marking of fire and emergency equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .../2-inch red letters: “General Alarm—When Bell Rings Go to Your Station.” (c) Steam, foam or CO 2 fire smothering apparatus. Steam, foam or CO2 fire smothering apparatus shall be marked “Steam Fire Apparatus” or “Foam Fire Apparatus” or “CO2 Fire Apparatus”, as appropriate, in not less than 2-inch red letters. The...

  14. 46 CFR 167.55-5 - Marking of fire and emergency equipment.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    .../2-inch red letters: “General Alarm—When Bell Rings Go to Your Station.” (c) Steam, foam or CO 2 fire smothering apparatus. Steam, foam or CO2 fire smothering apparatus shall be marked “Steam Fire Apparatus” or “Foam Fire Apparatus” or “CO2 Fire Apparatus”, as appropriate, in not less than 2-inch red letters. The...

  15. 46 CFR 167.55-5 - Marking of fire and emergency equipment.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    .../2-inch red letters: “General Alarm—When Bell Rings Go to Your Station.” (c) Steam, foam or CO 2 fire smothering apparatus. Steam, foam or CO2 fire smothering apparatus shall be marked “Steam Fire Apparatus” or “Foam Fire Apparatus” or “CO2 Fire Apparatus”, as appropriate, in not less than 2-inch red letters. The...

  16. 46 CFR 185.524 - Fire fighting drills and training.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Fire fighting drills and training. 185.524 Section 185... 100 GROSS TONS) OPERATIONS Preparations for Emergencies § 185.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar...

  17. 46 CFR 185.524 - Fire fighting drills and training.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Fire fighting drills and training. 185.524 Section 185... 100 GROSS TONS) OPERATIONS Preparations for Emergencies § 185.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar...

  18. 46 CFR 185.524 - Fire fighting drills and training.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Fire fighting drills and training. 185.524 Section 185... 100 GROSS TONS) OPERATIONS Preparations for Emergencies § 185.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar...

  19. 46 CFR 185.524 - Fire fighting drills and training.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Fire fighting drills and training. 185.524 Section 185... 100 GROSS TONS) OPERATIONS Preparations for Emergencies § 185.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar...

  20. 46 CFR 185.524 - Fire fighting drills and training.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Fire fighting drills and training. 185.524 Section 185... 100 GROSS TONS) OPERATIONS Preparations for Emergencies § 185.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar...

  1. 46 CFR 122.524 - Fire fighting drills and training.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fire fighting drills and training. 122.524 Section 122... Preparations for Emergencies § 122.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a...

  2. 46 CFR 122.524 - Fire fighting drills and training.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Fire fighting drills and training. 122.524 Section 122... Preparations for Emergencies § 122.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a...

  3. 46 CFR 122.524 - Fire fighting drills and training.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Fire fighting drills and training. 122.524 Section 122... Preparations for Emergencies § 122.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a...

  4. 46 CFR 122.524 - Fire fighting drills and training.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Fire fighting drills and training. 122.524 Section 122... Preparations for Emergencies § 122.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a...

  5. 46 CFR 122.524 - Fire fighting drills and training.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Fire fighting drills and training. 122.524 Section 122... Preparations for Emergencies § 122.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a...

  6. No Further Action Decision Under CERCLA, Study Area 31, Moore Army Airfield Fire Fighting Training Area, Fort Devens, Massachusetts

    DTIC Science & Technology

    1995-01-01

    FURTHER ACTION DECISION UNDER CERCLAI STUDY AREA 31 MOORE ARMY AIRFIELD FIRE FIGHTING TRAINING AREA FORT DEVENS , MASSACHUSETFS TABLE OF CONTENTS jSection...Inc. 31DD.DOC 6917.11 111,, NO FURTHER ACTION DECISION UNDER CERCLA I STUDY AREA 31 MOORE ARMY AIRFIELD FIRE FIGHTING TRAINING AREA 3 FORT DEVENS ...Fire Fighting Training Area) at Fort Devens , Massachusetts, have resulted in the decision that no further studies or remediation are required at this

  7. Acute toxicity of fire-control chemicals, nitrogenous chemicals, and surfactants to rainbow trout

    USGS Publications Warehouse

    Buhl, Kevin J.; Hamilton, Steven J.

    2000-01-01

    Laboratory studies were conducted to determine the acute toxicity of three ammonia-based fire retardants (Fire-Trol LCA-F, Fire-Trol LCM-R, and Phos-Chek 259F), five surfactant-based fire-suppressant foams (FireFoam 103B, FireFoam 104, Fire Quench, ForExpan S, and Pyrocap B-136), three nitrogenous chemicals (ammonia, nitrate, and nitrite), and two anionic surfactants (linear alkylbenzene sulfonate [LAS] and sodium dodecyl sulfate [SDS]) to juvenile rainbow trout Oncorhynchus mykiss in soft water. The descending rank order of toxicity (96-h concentration lethal to 50% of test organisms [96-h LC50]) for the fire retardants was as follows: Phos-Chek 259F (168 mg/L) > Fire-Trol LCA-F (942 mg/L) = Fire-Trol LCM-R (1,141 mg/L). The descending rank order of toxicity for the foams was as follows: FireFoam 103B (12.2 mg/L) = FireFoam 104 (13.0 mg/L) > ForExpan S (21.8 mg/L) > Fire Quench (39.0 mg/L) > Pyrocap B-136 [156 mg/L). Except for Pyrocap B-136, the foams were more toxic than the fire retardants. Un-ionized ammonia (NH3; 0.125 mg/L as N) was about six times more toxic than nitrite (0.79 mg/L NO2-N) and about 13,300 times more toxic than nitrate (1,658 mg/L NO3-N). Linear alkylbenzene sulfonate (5.0 mg/L) was about five times more toxic than SDS (24.9 mg/L). Estimated total ammonia and NH3 concentrations at the 96-h LC50s of the fire retardants indicated that ammonia was the primary toxic component in these formulations. Based on estimated anionic surfactant concentrations at the 96-h LC50s of the foams and reference surfactants, LAS was intermediate in toxicity and SDS was less toxic to rainbow trout when compared with the foams. Comparisons of recommended application concentrations to the test results indicate that accidental inputs of these chemicals into streams require substantial dilutions (100-1,750-fold to reach concentrations nonlethal to rainbow trout.

  8. Development of Defoamers for Confinenment Foam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoffman, D M; Mitchell, A R

    Aqueous foam concentrate (AFC) 380 foam was developed by Sandia National Laboratory as a blast mitigation foam for unexploded ordnance (UXO) and its ''engineered foam structure'' is reported to be able to ''envelop chemical or biological aerosols'' [1]. It is similar to commercial fire-fighting foams, consisting mostly of water with small amounts of two alcohols, an ether and surfactant. It also contains xanthan gum, probably, to strengthen the foam film and delay drainage. The concentrate is normally diluted in a 6:94 ratio with water for foaming applications. The diluted solution is normally foamed with air to an expansion factor ofmore » about 100 (density 0.01 g/cc), which is called ''dry'' foam. Higher density foam (0.18 > {rho} > 0.03 g/cc) was discovered which had quite different characteristics from ''dry'' foam and was called ''wet'' foam. Some characterization of these foams has also been carried out, but the major effort described in this document is the evaluation, at the small and medium scale, of chemical, mechanical and thermal approaches to defoaming AFC 380 foam. Several chemical approaches to defoaming were evaluated including oxidation and precipitation of the xanthan, use of commercial oil-emulsion or suspension defoamers, pH modification, and cation exchange with the surfactant. Of these the commercial defoamers were most effective. Two mechanical approaches to defoaming were evaluated: pressure and foam rupture with very fine particles. Pressure and vacuum techniques were considered too difficult for field applications but high surface area silica particles worked very well on dry foam. Finally simple thermal techniques were evaluated. An order-disorder transition occurs in xanthan solutions at about 60 C, which may be responsible for the effectiveness of hot air as a defoamer. During defoaming of 55 gallons of foam with hot air, after about 70% of the AFC 380 foam had been defoamed, the effectiveness of hot air was dramatically reduced. Approximately 15 gal of residual foam containing mostly small bubbles was resistant to further defoaming by methods that had been effective on the original, dry foam. In this paper the residual foam is referred to as ''wet'' and the original foam is referred to as ''dry''. Methods for generating ''wet'' foam in small to moderate quantities for defoaming experiments have been developed. Methods for defoaming wet foam are currently under study.« less

  9. US Coast Guard lightweight fire-fighting module

    NASA Astrophysics Data System (ADS)

    1980-05-01

    The U.S. Coast Guard Fire-fighting Module developed for the purpose of fighting fires in harbors and on ships is described. The module can be lifted by a dockside crane or helicopter and placed on the deck of a patrol boat or cutter for transportation to the scene of the fire. At the fire the module can be set up and put in operation by a crew of two in approximately fifteen minutes. Once in operation the module will deliver water to two fire nozzles at a pressure of 150 psi and a flow rate of 2000 gpm. Sufficient fuel is carried in the module for three hours of continuous operation. A record of the development of the fire fighting module is also presented.

  10. US Coast Guard lightweight fire-fighting module

    NASA Technical Reports Server (NTRS)

    1980-01-01

    The U.S. Coast Guard Fire-fighting Module developed for the purpose of fighting fires in harbors and on ships is described. The module can be lifted by a dockside crane or helicopter and placed on the deck of a patrol boat or cutter for transportation to the scene of the fire. At the fire the module can be set up and put in operation by a crew of two in approximately fifteen minutes. Once in operation the module will deliver water to two fire nozzles at a pressure of 150 psi and a flow rate of 2000 gpm. Sufficient fuel is carried in the module for three hours of continuous operation. A record of the development of the fire fighting module is also presented.

  11. Novel approach for extinguishing large-scale coal fires using gas-liquid foams in open pit mines.

    PubMed

    Lu, Xinxiao; Wang, Deming; Qin, Botao; Tian, Fuchao; Shi, Guangyi; Dong, Shuaijun

    2015-12-01

    Coal fires are a serious threat to the workers' security and safe production in open pit mines. The coal fire source is hidden and innumerable, and the large-area cavity is prevalent in the coal seam after the coal burned, causing the conventional extinguishment technology difficult to work. Foams are considered as an efficient means of fire extinguishment in these large-scale workplaces. A noble foam preparation method is introduced, and an original design of cavitation jet device is proposed to add foaming agent stably. The jet cavitation occurs when the water flow rate and pressure ratio reach specified values. Through self-building foaming system, the high performance foams are produced and then infused into the blast drilling holes at a large flow. Without complicated operation, this system is found to be very suitable for extinguishing large-scale coal fires. Field application shows that foam generation adopting the proposed key technology makes a good fire extinguishment effect. The temperature reduction using foams is 6-7 times higher than water, and CO concentration is reduced from 9.43 to 0.092‰ in the drilling hole. The coal fires are controlled successfully in open pit mines, ensuring the normal production as well as the security of personnel and equipment.

  12. 46 CFR 35.40-10 - Steam, foam, carbon dioxide, or clean agent fire smothering apparatus-TB/ALL.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 1 2013-10-01 2013-10-01 false Steam, foam, carbon dioxide, or clean agent fire... TANK VESSELS OPERATIONS Posting and Marking Requirements-TB/ALL § 35.40-10 Steam, foam, carbon dioxide, or clean agent fire smothering apparatus—TB/ALL. Each steam, foam, carbon dioxide, or clean agent...

  13. 46 CFR 35.40-10 - Steam, foam, carbon dioxide, or clean agent fire smothering apparatus-TB/ALL.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 1 2014-10-01 2014-10-01 false Steam, foam, carbon dioxide, or clean agent fire... TANK VESSELS OPERATIONS Posting and Marking Requirements-TB/ALL § 35.40-10 Steam, foam, carbon dioxide, or clean agent fire smothering apparatus—TB/ALL. Each steam, foam, carbon dioxide, or clean agent...

  14. 46 CFR 109.223 - Fire fighting equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fire fighting equipment. 109.223 Section 109.223 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Tests, Drills, and Inspections § 109.223 Fire fighting equipment. The master or person in charge...

  15. 46 CFR 109.223 - Fire fighting equipment.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Fire fighting equipment. 109.223 Section 109.223 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Tests, Drills, and Inspections § 109.223 Fire fighting equipment. The master or person in charge...

  16. 46 CFR 109.223 - Fire fighting equipment.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Fire fighting equipment. 109.223 Section 109.223 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Tests, Drills, and Inspections § 109.223 Fire fighting equipment. The master or person in charge...

  17. 46 CFR 109.223 - Fire fighting equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Fire fighting equipment. 109.223 Section 109.223 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Tests, Drills, and Inspections § 109.223 Fire fighting equipment. The master or person in charge...

  18. 46 CFR 109.223 - Fire fighting equipment.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Fire fighting equipment. 109.223 Section 109.223 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS Tests, Drills, and Inspections § 109.223 Fire fighting equipment. The master or person in charge...

  19. 14 CFR 91.815 - Agricultural and fire fighting airplanes: Noise operating limitations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 2 2011-01-01 2011-01-01 false Agricultural and fire fighting airplanes... RULES Operating Noise Limits § 91.815 Agricultural and fire fighting airplanes: Noise operating limitations. (a) This section applies to propeller-driven, small airplanes having standard airworthiness...

  20. 14 CFR 91.815 - Agricultural and fire fighting airplanes: Noise operating limitations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 2 2013-01-01 2013-01-01 false Agricultural and fire fighting airplanes... RULES Operating Noise Limits § 91.815 Agricultural and fire fighting airplanes: Noise operating limitations. (a) This section applies to propeller-driven, small airplanes having standard airworthiness...

  1. 14 CFR 91.815 - Agricultural and fire fighting airplanes: Noise operating limitations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 2 2012-01-01 2012-01-01 false Agricultural and fire fighting airplanes... RULES Operating Noise Limits § 91.815 Agricultural and fire fighting airplanes: Noise operating limitations. (a) This section applies to propeller-driven, small airplanes having standard airworthiness...

  2. 14 CFR 91.815 - Agricultural and fire fighting airplanes: Noise operating limitations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Agricultural and fire fighting airplanes... RULES Operating Noise Limits § 91.815 Agricultural and fire fighting airplanes: Noise operating limitations. (a) This section applies to propeller-driven, small airplanes having standard airworthiness...

  3. 77 FR 70172 - Lifesaving and Fire-Fighting Equipment, Training and Drills Onboard Offshore Facilities and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-23

    ... Equipment, Training and Drills Onboard Offshore Facilities and Mobile Offshore Drilling Units (MODUs... lifesaving and fire-fighting equipment, training and drills on board offshore facilities and MODUs operating... guidance concerning lifesaving and fire-fighting equipment, training, and drills onboard manned offshore...

  4. Crew size affects fire fighting efficiency: A progress report on time studies of the fire fighting job.

    Treesearch

    Donald N. Matthews

    1940-01-01

    Fire fighting is still largely a hand-work job in the heavy cover and fuel conditions and rugged topography of the Douglas fir region, in spite of recent advances that have been made in %he use of machinery. Controlling a fire in this region requires immense amounts of work per unit of fire perimeter, so that large numbers of men are required to attack all but the...

  5. Fire retardant polyisocyanurate foam

    NASA Technical Reports Server (NTRS)

    Riccitiello, S. R.; Parker, J. A.

    1972-01-01

    Fire retardant properties of low density polymer foam are increased. Foam has pendant nitrile groups which form thermally-stable heterocyclic structures at temperature below degradation temperature of urethane linkages.

  6. Flexible fire retardant polyisocyanate modified neoprene foam. [for thermal protective devices

    NASA Technical Reports Server (NTRS)

    Parker, J. A.; Riccitiello, S. R. (Inventor)

    1973-01-01

    Lightweight, fire resistant foams have been developed through the modification of conventional neoprene-isocyanate foams by the addition of an alkyl halide polymer. Extensive tests have shown that the modified/neoprene-isocyanate foams are much superior in heat protection properties than the foams heretofore employed both for ballistic and ablative purposes.

  7. Performance of Aqueous Film Forming Foam (AFFF) on Large-Scale Hydroprocessed Renewable Jet (HRJ) Fuel Fires

    DTIC Science & Technology

    2011-12-01

    aqueous film forming foam ( AFFF ) firefighting agents and equipment are capable of...AFRL-RX-TY-TR-2012-0012 PERFORMANCE OF AQUEOUS FILM FORMING FOAM ( AFFF ) ON LARGE-SCALE HYDROPROCESSED RENEWABLE JET (HRJ) FUEL FIRES...Performance of Aqueous Film Forming Foam ( AFFF ) on Large-Scale Hydroprocessed Renewable Jet (HRJ) Fuel Fires FA4819-09-C-0030 0602102F 4915 D0

  8. STS-42 crewmembers participate in JSC fire fighting training exercises

    NASA Technical Reports Server (NTRS)

    1991-01-01

    STS-42 Discovery, Orbiter Vehicle (OV) 103, Payload Specialist Ulf D. Merbold (far left), fire fighting trainer (center), Payload Specialist Roberta L. Bondar (holding hose nozzle), and backup Payload Specialist Roger K. Crouch position water hoses in the direction of a blazing fire in JSC's Fire Training Pit. The crewmembers and backup are learning fire extinguishing techniques during fire fighting and fire training exercises held at JSC's Fire Training Pit located across from the Gilruth Center Bldg 207. Merbold is representing the European Space Agency (ESA) and Bondar is representing Canada during the International Microgravity Laboratory 1 (IML-1) mission aboard OV-103.

  9. Decree No. 849/988 of 14 December 1988 setting forth regulations on the prevention and combat of forest fires.

    PubMed

    1989-01-01

    This Uruguayan Decree sets forth regulations on the prevention and fighting of forest fires. Among other things, it does the following: 1) requires all public and private organizations, as well as all persons, to assist personally in and provide vehicles, machines, and tools for the fighting of forest fires; 2) requires the owners of property containing forests to maintain instruction in fighting fires for an adequate number of employees; 3) requires all forests to be kept cleared of vegetation capable of spreading fires and to have fire walls; 4) requires owners of forests larger than 30 hectares in size to present to the Forest Directorate an annual plan for forest fire defense; and 5) requires owners of forests larger than 30 hectares in size to maintain specified equipment for fighting fires. Persons violating the provisions of this Decree are subject to fines.

  10. Study on the generation of perfluorooctane sulfonate from the aqueous film-forming foam.

    PubMed

    Kishi, Takahiro; Arai, Mitsuru

    2008-11-15

    Perfluorooctane sulfonate (C(8)HF(17)SO(3)) and perfluorooctane acid (C(8)HF(15)O(2)) are artificial chemicals and have been used all over the world, mainly as water repellent agents, fluorochemical surfactants, coating agents, etc. However, perfluorooctane sulfonate and perfluorooctane acid are environmental contaminants because of their stability, bio-accumulativeness, and long-term persistence in the ecological environment. At the present day, they are diffused all over the world. Lately, this diffusion is viewed with suspicion and there is a movement towards their restriction, even if the environmental fate of them is still under investigation. Fluorochemical surfactants are key compounds in the aqueous film-forming foam (AFFF) formulations. AFFFs are used for massive conflagration such as industrial fire and petroleum fire because of their efficient fire control. On the other hand, a lot of AFFFs are used in case of massive conflagration and most of them enter ocean and groundwater. Actually, perfluorooctane sulfonate and perfluorooctane sulfonate related substances were detected from the fire-fighting facility of US forces. Therefore, there is the possibility of generating perfluorooctane sulfonate and perfluorooctane sulfonate related substances from fluorochemical surfactants in the AFFFs. In this study, activated sludge added AFFF were analyzed for perfluorooctane sulfonate and perfluorooctane acid with time. And the perfluorooctane sulfonate was directly detected after 2 days using LC-MS. This shows that AFFF can be decomposed perfluorooctane sulfonate by microorganisms easily. However, perfluorooctane sulfonate would not decompose at all. Additionally, activated sludge added N-polyoxyethylene-N-propyl perfluorooctane sulfonamide which is one of the fluorochemical surfactants used in the AFFF was analyzed for perfluorooctane sulfonate and perfluorooctane acid with time and the perfluorooctane sulfonate was detected too.

  11. Discovery of novel per- and polyfluoroalkyl substances (PFASs) at a fire fighting training ground and preliminary investigation of their fate and mobility.

    PubMed

    Baduel, Christine; Mueller, Jochen F; Rotander, Anna; Corfield, John; Gomez-Ramos, Maria-José

    2017-10-01

    Aqueous film forming foams (AFFFs) have been released at fire training facilities for several decades resulting in the contamination of soil and groundwater by per- and polyfluoroalkyl substances (PFASs). AFFF compositions are proprietary and may contain a broad range of PFASs for which the chemical structures and degradation products are not known. In this study, high resolution quadrupole-time-of-flight tandem mass spectrometry (LC-QTOF-MS/MS) in combination with data processing using filtering strategies was applied to characterize and elucidate the PFASs present in concrete extracts collected at a fire training ground after the historical use of various AFFF formulations. Twelve different fluorochemical classes, representing more than 60 chemicals, were detected and identified in the concrete extracts. Novel PFASs homologues, unmonitored before in environmental samples such as chlorinated PFSAs, ketone PFSAs, dichlorinated PFSAs and perfluoroalkane sulphonamides (FASAs) were detected in soil samples collected in the vicinity of the fire training ground. Their detection in the soil cores (from 0 to 2 m) give an insight on the potential mobility of these newly identified PFASs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. 49 CFR 178.358 - Specification 21PF fire and shock resistant, phenolic-foam insulated, metal overpack.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Specification 21PF fire and shock resistant, phenolic-foam insulated, metal overpack. 178.358 Section 178.358 Transportation Other Regulations Relating...) Materials § 178.358 Specification 21PF fire and shock resistant, phenolic-foam insulated, metal overpack. ...

  13. 49 CFR 178.358 - Specification 21PF fire and shock resistant, phenolic-foam insulated, metal overpack.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Specification 21PF fire and shock resistant, phenolic-foam insulated, metal overpack. 178.358 Section 178.358 Transportation Other Regulations Relating... Class 7 (Radioactive) Materials § 178.358 Specification 21PF fire and shock resistant, phenolic-foam...

  14. Crisis management with applicability on fire fighting plants

    NASA Astrophysics Data System (ADS)

    Panaitescu, M.; Panaitescu, F. V.; Voicu, I.; Dumitrescu, L. G.

    2017-08-01

    The paper presents a case study for a crisis management analysis which address to fire fighting plants. The procedures include the steps of FTA (Failure tree analysis). The purpose of the present paper is to describe this crisis management plan with tools of FTA. The crisis management procedures have applicability on anticipated and emergency situations and help to describe and planning a worst-case scenario plan. For this issue must calculate the probabilities in different situations for fire fighting plants. In the conclusions of paper is analised the block diagram with components of fire fighting plant and are presented the solutions for each possible risk situations.

  15. Formulation and performance test of palm-based foaming agent concentrate for fire extinguisher application

    NASA Astrophysics Data System (ADS)

    Rivai, M.; Hambali, E.; Suryani, A.; Fitria, R.; Firmansyah, S.; Pramuhadi, G.

    2018-03-01

    The utilization of foaming agent for fire extinguisher application improves the efficiency of water as a fire extinguishing agent, lowers surface tension, and acts as a foaming agent. The formed foam cools the fire down and covers the burned material to avoid it from further contact with oxygen which may reignite the fire. This study aimed to produce and assess the performance of foaming agent concentrate from palm oil as a fire extinguisher agent. In the performance test, measurements were taken on foam stability, foaming ability, surface tension, interfacial tension, viscosity, contact angle, density, and specific gravity. The formulation was conducted by using the best produced potassium palmitate, potassium methyl ester, and sodium lauric combined with diluents, chelating agent, and other additives at various composition comparisons. The produced foaming agent concentrate was found to be in a rather paste and liquid form with viscosity of 2.34 – 253 cP. It was also found that the resulted foaming agent concentrate dissolved in water at the concentration rate of 1% had a foam stability level of 30-91%, foaming ability of 288 – 503%, surface tension of 19.68 – 25.05 dyne/cm, interfacial tension of 0.54 – 4,20 dyne/cm, viscosity of 1.00 – 1.05 cP, contact angles of 53.75 – 63.79° at 0 minute and 11.84 – 22.42 ° at minute 10, density of 0.99586 – 0.99612 g/cm3, and a specific gravity of 1.00021 – 1.00046. Based on foam stability, foaming ability, and surface tension parameters, it was concluded that NF5 and NF17 were the best formulas.Compared to the other formulas, NF5 formula had the best droplet diameter (minimum 0.14 mm) and droplet density (maximum 3056 droplets/cm2).

  16. 46 CFR 108.477 - Fire hydrants.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fire hydrants. 108.477 Section 108.477 Shipping COAST... Fire Extinguishing Systems Foam Extinguishing Systems § 108.477 Fire hydrants. (a) If a fixed foam extinguishing system has outlets in a main machinery space, at least 2 fire hydrants, in addition to the fire...

  17. Measuring wildland fire fighter performance with wearable technology.

    PubMed

    Parker, Richard; Vitalis, Antonios; Walker, Robyn; Riley, David; Pearce, H Grant

    2017-03-01

    Wildland (rural) fire fighting is a physically demanding and hazardous occupation. An observational study was conducted to explore the use of new technologies for the field study of fire fighters at wildfires and to understand the work pressures of wildland fire fighting. The research was carried out with two fire fighters at real fires wearing microphones, miniature video cameras, heart rate monitors and GPS units to record their actions and location at wildfire events. The fire fighters were exposed to high physiological workloads (heart rates of up to 180 beats per minute) and walked considerable distances at the fires. Results from this study have been used in presentations to fire fighters and non-operational fire personnel to understand the pressures fire fighters are under and how others complete the fire fighting tasks. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Fire extinguishing tests -80 with methyl alcohol gasoline

    NASA Astrophysics Data System (ADS)

    Holmstedt, G.; Ryderman, A.; Carlsson, B.; Lennmalm, B.

    1980-10-01

    Large scale tests and laboratory experiments were carried out for estimating the extinguishing effectiveness of three alcohol resistant aqueous film forming foams (AFFF), two alcohol resistant fluoroprotein foams and two detergent foams in various poolfires: gasoline, isopropyl alcohol, acetone, methyl-ethyl ketone, methyl alcohol and M15 (a gasoline, methyl alcohol, isobutene mixture). The scaling down of large scale tests for developing a reliable laboratory method was especially examined. The tests were performed with semidirect foam application, in pools of 50, 11, 4, 0.6, and 0.25 sq m. Burning time, temperature distribution in the liquid, and thermal radiation were determined. An M15 fire can be extinguished with a detergent foam, but it is impossible to extinguish fires in polar solvents, such as methyl alcohol, acetone, and isopropyl alcohol with detergent foams, AFFF give the best results; and performances with small pools can hardly be correlated with results from large scale fires.

  19. Ambient curing fire resistant foams

    NASA Technical Reports Server (NTRS)

    Hamermesh, C. L.; Hogenson, P. A.; Tung, C. Y.; Sawko, P. M.; Riccitiello, S. R.

    1979-01-01

    The feasibility of development of an ambient curing foam is described. The thermal stability and flame spread index of the foams were found to be comparable to those of the high-temperature cured polyimide foams by Monsanto two-foot tunnel test and NASA T-3 Fire test. Adaptation of the material to spray in place applications is described

  20. Solar pond

    NASA Technical Reports Server (NTRS)

    Miller, C. G.; Stephens, J. B. (Inventor)

    1978-01-01

    Shallow pools of liquid to collect low-temperature solar generated thermal energy are described. Narrow elongated trenches, grouped together over a wide area, are lined with a heat-absorbing black liner. The heat-absorbing liquid is kept separate from the thermal energy removing fluid by means such as clear polyethylene material. The covering for the pond may be a fluid or solid. If the covering is a fluid, fire fighting foam, continuously generated, or siloons are used to keep the surface covering clean and insulated. If the thermal energy removing fluid is a gas, a fluid insulation layer contained in a flat polyethlene tubing is used to cover the pond. The side of the tube directed towards the sun is treated to block out ultraviolet radiation and trap in infrared radiation.

  1. A WebGIS-based command control system for forest fire fighting

    NASA Astrophysics Data System (ADS)

    Yang, Jianyu; Ming, Dongping; Zhang, Xiaodong; Huang, Haitao

    2006-10-01

    Forest is a finite resource and fire prevention is crucial work. However, once a forest fire or accident occurs, timely and effective fire-fighting is the only necessary measure. The aim of this research is to build a computerized command control system based on WEBGIS to direct fire-fighting. Firstly, this paper introduces the total technique flow and functional modules of the system. Secondly, this paper analyses the key techniques for building the system, and they are data obtaining, data organizing & management, architecture of WebGIS and sharing & interoperation technique. In the end, this paper demonstrates the on line martial symbol editing function to show the running result of system. The practical application of this system showed that it played very important role in the forest fire fighting work. In addition, this paper proposes some strategic recommendations for the further development of the system.

  2. STS-30 crewmembers participate in fire fighting training at JSC

    NASA Technical Reports Server (NTRS)

    1989-01-01

    STS-30 Atlantis, Orbiter Vehicle (OV) 104, crewmembers participate in fire fighting training at JSC's fire training pit across from the Gilruth Center Bldg 207. Commander David M. Walker and Pilot Ronald J. Grabe use fire extinguishers to control blaze. Fire / security staff member Robert Fife coaches the two crewmembers during the training exercise.

  3. Fire performances of foam core particleboards continuously produced in a one-step process

    Treesearch

    Ali Shalbafan; Mark A. Dietenberger; Johannes Welling

    2013-01-01

    For further progress of novel foam core particleboards, their fire performance was examined with cone calorimetry tests (ASTM E 1354-11a). Specimens with varying surface layer thicknesses, foam densities (polystyrene foam), and processing temperatures were tested. Using the initially recommended cone irradiance of 35 kW/m2, different flammability...

  4. 46 CFR 108.477 - Fire hydrants.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Fire hydrants. 108.477 Section 108.477 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Foam Extinguishing Systems § 108.477 Fire hydrants. (a) If a fixed foam...

  5. STS-47 crew participates in fire fighting exercises at JSC Fire Training Pit

    NASA Technical Reports Server (NTRS)

    1992-01-01

    STS-47 Endeavour, Orbiter Vehicle (OV) 105, Mission Specialist (MS) N. Jan Davis (foreground) and MS and Payload Commander (PLC) Mark C. Lee, squinting and holding water hose, listen to instructions prior to participating in fire fighting exercises held at JSC's Fire Training Pit across from Gilruth Center Bldg 207.

  6. STS-48 crew participates in JSC fire fighting and fire training exercises

    NASA Technical Reports Server (NTRS)

    1991-01-01

    In this overall view, STS-48 crewmembers approach a firey blaze armed with water hoses. Left to right are Mission Specialist (MS) Charles D. Gemar, Pilot Kenneth S. Reightler, Jr, an unidentified fire department Official, MS Mark N. Brown, and Commander John O. Creighton. These fire fighting and fire training exercises were conducted at JSC's Fire Training Pit located across from the Gilruth Center Bldg 207.

  7. New fire retardant foams and intumescents

    NASA Technical Reports Server (NTRS)

    Parker, J. A.

    1972-01-01

    The development of fire retardant foams and intumescent paints for protection of commercial aircraft passengers in the event of fire is discussed. Recommended materials and methods for evaluating the effectiveness of the materials are presented. Typical problems resulting from aircraft fires and the basic protective mechanisms to cope with these problems are examined.

  8. 46 CFR 35.40-10 - Steam, foam, carbon dioxide, or clean agent fire smothering apparatus-TB/ALL.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 1 2012-10-01 2012-10-01 false Steam, foam, carbon dioxide, or clean agent fire smothering apparatus-TB/ALL. 35.40-10 Section 35.40-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS OPERATIONS Posting and Marking Requirements-TB/ALL § 35.40-10 Steam, foam, carbon dioxide, or clean agent fire smothering apparatus—TB...

  9. Fire extinguishing tests -80 with methyl alcohol gasoline (in MIXED)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holmstedt, G.; Ryderman, A.; Carlsson, B.

    1980-01-01

    Large scale tests and laboratory experiments were carried out for estimating the extinguishing effectiveness of three alcohol resistant aqueous film forming foams (AFFF), two alcohol resistant fluoroprotein foams and two detergent foams in various poolfires: gasoline, isopropyl alcohol, acetone, methyl-ethyl ketone, methyl alcohol and M15 (a gasoline, methyl alcohol, isobutene mixture). The scaling down of large scale tests for developing a reliable laboratory method was especially examined. The tests were performed with semidirect foam application, in pools of 50, 11, 4, 0.6, and 0.25 sq m. Burning time, temperature distribution in the liquid, and thermal radiation were determined. An M15more » fire can be extinguished with a detergent foam, but it is impossible to extinguish fires in polar solvents, such as methyl alcohol, acetone, and isopropyl alcohol with detergent foams, AFFF give the best results, and performances with small pools can hardly be correlated with results from large scale fires.« less

  10. Toxicity of fire retardant chemicals to aquatic organisms: Progress report

    USGS Publications Warehouse

    Hamilton, Steven J.; McDonald, Susan F.; Gaikowski, Mark P.; Buhl, Kevin J.; Ramsey, G.S.

    1996-01-01

    Fire retardants and suppressants used extensively in North America are often applied in environmentally sensitive areas that may contain endangered, threatened, or economically important plant and animal species. We conducted laboratory acute toxicity tests in both hard and soft waters with five commonly used fire control chemicals (Fire Trol LCG-R, Fire-Trol GTS-R, Phos-Chek D-75-F, Phos-Chek WD-881, and Silv-Ex). Organisms used in the tests included two fish (rainbow trout and fathead minnow), two aquatic invertebrates (Daphnia magna and Hyalella azteca), and a green algae (Selenastrum capricornutum). In general, the green algae was substantially more sensitive to the three non-foam fire chemicals than the animals, the Daphnia were the most sensitive test organism in exposures with foams. The two foams (Silv-Ex and Phos-Chek WD-881) had similar toxicity and were more toxic than the three non-foams. Water quality did not seem to modify the toxicity of the five fire chemicals in a consistent manner.

  11. STS-48 crew participates in JSC fire fighting and fire training exercises

    NASA Technical Reports Server (NTRS)

    1991-01-01

    STS-48 Mission Specialist (MS) Charles D. Gemar opens water hose nozzle as he approaches a fire blazing in JSC's Fire Training Pit during fire fighting and fire training exercises. Pilot Kenneth S. Reightler, Jr steadies the hose behind Gemar. At Gemars right is an unidentified fire department Official, MS Mark N. Brown, and Commander John O. Creighton. Brown and Crieghton are obscured by the water spray. The Fire Training Pit is located across from the Gilruth Center Bldg 207.

  12. NASA helicopter helps fight fire at KSC

    NASA Technical Reports Server (NTRS)

    2000-01-01

    A NASA helicopter takes off to bring water to fight a small fire on Kennedy Space Center grounds. The site is between Kennedy Parkway North and the Indian River. The fire is one of many throughout Central Florida, which is suffering from drought.

  13. Thermal conductivity and combustion properties of wheat gluten foams.

    PubMed

    Blomfeldt, Thomas O J; Nilsson, Fritjof; Holgate, Tim; Xu, Jianxiao; Johansson, Eva; Hedenqvist, Mikael S

    2012-03-01

    Freeze-dried wheat gluten foams were evaluated with respect to their thermal and fire-retardant properties, which are important for insulation applications. The thermal properties were assessed by differential scanning calorimetry, the laser flash method and a hot plate method. The unplasticised foam showed a similar specific heat capacity, a lower thermal diffusivity and a slightly higher thermal conductivity than conventional rigid polystyrene and polyurethane insulation foams. Interestingly, the thermal conductivity was similar to that of closed cell polyethylene and glass-wool insulation materials. Cone calorimetry showed that, compared to a polyurethane foam, both unplasticised and glycerol-plasticised foams had a significantly longer time to ignition, a lower effective heat of combustion and a higher char content. Overall, the unplasticised foam showed better fire-proof properties than the plasticized foam. The UL 94 test revealed that the unplasticised foam did not drip (form droplets of low viscous material) and, although the burning times varied, self-extinguished after flame removal. To conclude both the insulation and fire-retardant properties were very promising for the wheat gluten foam. © 2012 American Chemical Society

  14. An assessment of air quality impacts of fires associated with fire fighting operations.

    PubMed

    Leahey, D M; Hansen, M C; Schroeder, M B

    1993-03-01

    Fire fighters in Canada's navy must undergo regular training with fires from simulated helicopter crashes. Visible emissions from these fires often create health concerns in surrounding communities. This paper presents air quality implications of plume dispersion associated with "helicopter fires." Evaluations involved measuring plume rise, estimating emissions, dispersion modeling and ambient monitoring. Results of the evaluation provided ground-level concentration estimates of plume particulate matter, oxides of nitrogen, hydrogen fluoride, carbon monoxide, 22 metals, 15 PAH and 13 VOC. The study showed that the air quality impact of the fire fighting training is much lower than the relevant time-weighted averages established to protect workers' health. This paper will be of interest to people in environmental protection agencies because it demonstrates the effects of fire fighting operations that must frequently occur as part of training exercises.

  15. Fire fighting aboard ships. Volume 1: Hazard analysis and behavior of combustible materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stavitskiy, M.G.; Kortunov, M.F.; Sidoryuk, V.M.

    1983-01-01

    The volume zeros in on fire hazards on ships afloat or under construction/repair. It examines fire hazards peculiar to ships carrying particular cargoes, such as dry-cargo ships, tankers, and factory and fishing vessels. This volume examines specific features of fire-fighting equipment, along with the thermal behavior of materials used in shipbuilding.

  16. Training Effectiveness Evaluation (TEE) of the Advanced Fire Fighting Training System. Focus on the Trained Person.

    ERIC Educational Resources Information Center

    Cordell, Curtis C.; And Others

    A training effectiveness evaluation of the Navy Advanced Fire Fighting Training System was conducted. This system incorporates simulated fires as well as curriculum materials and instruction. The fires are non-pollutant, computer controlled, and installed in a simulated shipboard environment. Two teams of 15 to 16 persons, with varying amounts of…

  17. NASA helicopter helps fight brush fire at KSC

    NASA Technical Reports Server (NTRS)

    2000-01-01

    A NASA helicopter flies over fire-fighting equipment and personnel in order to drop its load of water on a wildfire at KSC. Before being extinguished, the fire burned about 20 acres at a site near gate 2C on Kennedy Parkway North (route 3).

  18. Manual Fire Suppression Methods on Typical Machinery Space Spray Fires

    DTIC Science & Technology

    1990-07-31

    Aqueous Film Forming Foam Manuscnpt approved April 25, 1990. ( AFFF ), has been incorporated in machinery space fire protection systems to...distribution unlimited. 13. ABSTRACT (Maximum 200 words) A series of tests was conducted to evaluate the effectiveness of Aqueous Film Forming Foami ( AFFF ...machinery space fire protection systems to control running fuel and fuel spray fires (PKP side of TAFES), and bilge fires ( aqueous film forming foam

  19. Fire and ecotoxicological aspects of polyurethane rigid foam.

    PubMed

    Wittbecker, F W; Giersig, M

    2001-01-01

    The main characteristics of fire effluents from polyurethane (PUR) foams are comparable to those from natural materials like wood, cork, or wool. This similarity has been demonstrated by comparative data from analytical and toxicological studies. It is therefore presumed that effluents of these materials present similar hazards to human beings and the environment. In almost all fires, dioxins can be found in the smoke and residues. In fires involving PURs, relevant quantities of halogenated dioxins or furans are not to be expected; this has been confirmed by investigations under controlled laboratory conditions. The insulation properties of rigid PUR foam contribute significantly to environmental protection and the conservation of resources. A number of methods for reusing and recycling PUR rigid foam waste have been developed and realized in practise. The possibilities range from reusing the material itself, generating liquid raw materials, and thermal recycling, even for (H)CFC-containing PUR rigid foams, by cocombustion in suitable plants.

  20. Nano-fibrillated cellulose-hydroxyapatite based composite foams with excellent fire resistance.

    PubMed

    Guo, Wenwen; Wang, Xin; Zhang, Ping; Liu, Jiajia; Song, Lei; Hu, Yuan

    2018-09-01

    Thermally insulating materials made from renewable resources are desirable for energy efficient buildings. Traditional petroleum-derived insulating materials such as rigid polyurethane foam and expanded polystyrene display poor flame retardancy and inorganic insulating materials such as silica aerogel are fragile. Herein, we reported a facile approach to prepare cellulose nanofiber (CNF)-hydroxyapatite (HAP) composite foam by a simple freeze-drying process. The resultant HAP-CNF composite foams showed a thermal conductivity in the range of 38.5-39.1 mW/(m K) and very low peak heat release rate (20.4 kW/m 2 ) and total heat release (1.21 MJ/m 2 ). Vertical burning tests also manifested excellent fire resistance and self-extinguishing behaviours. Considering the excellent fire resistance of this composite foam, it is of significance to fire safety solution for buildings insulating materials. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. NASA helicopter helps fight brush fire at KSC

    NASA Technical Reports Server (NTRS)

    2000-01-01

    A NASA helicopter dips its fire-fighting bucket into the river to pick up and deliver a cargo of water to a wildfire at KSC. Before being extinguished, the fire burned about 20 acres at a site near gate 2C on Kennedy Parkway North (route 3).

  2. Cascading effects of fire exclusion in the Rocky Mountain ecosystems: a literature review

    Treesearch

    Robert E. Keane; Kevin C. Ryan; Tom T. Veblen; Craig D. Allen; Jessie Logan; Brad Hawkes

    2002-01-01

    The health of many Rocky Mountain ecosystems is in decline because of the policy of excluding fire in the management of these ecosystems. Fire exclusion has actually made it more difficult to fight fires, and this poses greater risks to the people who fight fires and for those who live in and around Rocky Mountain forests and rangelands. This paper discusses the extent...

  3. Light, Compact Pumper for Harbor Fires

    NASA Technical Reports Server (NTRS)

    Burns, R. A.

    1983-01-01

    Report describes development of new transportable water-pumping unit for fire-fighting. Compact, self-contained unit provides fire protection at coastal and inland ports and is lighter than standard firetruck pumper of same capacity. Used to fight fires in harbors, cities, forests, refineries, chemical plants, and offshore drilling platforms. Other possible applications include cleaning up oilspills, pumping out ships, and flood control pumping.

  4. Information processing in an urban fire department communication system.

    PubMed

    Siegel, J; Weitzman, D O

    1975-09-01

    One of the most important functions of any fire department is to provide selective contact with fire fighting units and to dispatch these units based on information gathered from street alarm boxes and telephones. This paper is concerned with the problem of dispatching tactical response information to remote fire fighting units and with the effect of workload on the dispatch function.

  5. Self-Contained AFFF Sprinkler System,

    DTIC Science & Technology

    1982-05-01

    aqueous film forming foam ( AFFF ). Such systems are...supply. Extinguishing Agents All fire tests were run with a pre-mixed solution of 6% aqueous film forming foam ( AFFF ) agent in accordance with MIL-F...Applying Aqueous Film Forming Foam on Large-Scale Fires", Civil and Environmental Engineering Development Office (Air Force Systems Command) Report

  6. STS-48 crew participates in JSC fire fighting and fire training exercises

    NASA Technical Reports Server (NTRS)

    1991-01-01

    STS-48 Pilot Kenneth S. Reightler, Jr directs water hose nozzle as Mission Specialist (MS) Charles D. Gemar pulls the hose toward the blaze. In the background, an unidentified fire department Official instructs Commander John O. Creighton and MS Mark N. Brown (wearing cap), manning a second hose, on how to approach the blaze. These fire fighting and fire training exercises were conducted at JSC's Fire Training Pit located across from the Gilruth Center Bldg 207.

  7. Fire-retardant foams

    NASA Technical Reports Server (NTRS)

    Gagliani, J.

    1978-01-01

    Family of polyimide resins are being developed as foams with exceptional fire-retardant properties. Foams are potentially useful for seat cushions in aircraft and ground vehicles and for applications such as home furnishings and building-construction materials. Basic formulations can be modified with reinforcing fibers or fillers to produce celular materials for variety of applications. By selecting reactants, polymer structure can be modified to give foams with properties ranging from high resiliency and flexibility to brittleness and rigidity.

  8. Extreme toxicity from combustion products of a fire-retarded polyurethane foam.

    PubMed

    Petajan, J H; Voorhees, K J; Packham, S C; Baldwin, R C; Einhorn, I N; Grunnet, M L; Dinger, B G; Birky, M M

    1975-02-28

    The products from nonflaming combustion of wood and a trimethylol-propane-based rigid-urethane foam that was not fire-retarded produced elevated carboxyhemoglobin levels but no abnormal neurological effects. However, when this type of foam contained a reactive phosphate fire retardant, the combustion products caused grand mal seizures and death in rats. The toxic combustion product responsible for the seizures has been identified as 4-ethyl-1-phospha-2,6,7-trioxabicyclo(2.2.2.)octane-1-oxide.

  9. 30 CFR 75.1103-9 - Minimum requirements; fire suppression materials and location; maintenance of entries and...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... tools and hardware required for its operation shall be stored at the foam generator. (2) Tools to open a...-expansion foam devices. 75.1103-9 Section 75.1103-9 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... and crosscuts; access doors; communications; fire crews; high-expansion foam devices. (a) The...

  10. 30 CFR 75.1103-9 - Minimum requirements; fire suppression materials and location; maintenance of entries and...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... tools and hardware required for its operation shall be stored at the foam generator. (2) Tools to open a...-expansion foam devices. 75.1103-9 Section 75.1103-9 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... and crosscuts; access doors; communications; fire crews; high-expansion foam devices. (a) The...

  11. 30 CFR 75.1103-9 - Minimum requirements; fire suppression materials and location; maintenance of entries and...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... tools and hardware required for its operation shall be stored at the foam generator. (2) Tools to open a...-expansion foam devices. 75.1103-9 Section 75.1103-9 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... and crosscuts; access doors; communications; fire crews; high-expansion foam devices. (a) The...

  12. 30 CFR 75.1103-9 - Minimum requirements; fire suppression materials and location; maintenance of entries and...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... tools and hardware required for its operation shall be stored at the foam generator. (2) Tools to open a...-expansion foam devices. 75.1103-9 Section 75.1103-9 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... and crosscuts; access doors; communications; fire crews; high-expansion foam devices. (a) The...

  13. 30 CFR 75.1103-9 - Minimum requirements; fire suppression materials and location; maintenance of entries and...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... tools and hardware required for its operation shall be stored at the foam generator. (2) Tools to open a...-expansion foam devices. 75.1103-9 Section 75.1103-9 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... and crosscuts; access doors; communications; fire crews; high-expansion foam devices. (a) The...

  14. The performance of lightweight plastic foams developed for fire safety

    NASA Technical Reports Server (NTRS)

    Fish, R. H.

    1971-01-01

    The use of a low density, polyurethane based foam to suppress a fire and to provide protection for the structure of an aircraft or spacecraft is discussed. The mechanism by which foams provide protection from heat and create a nonflammable surface is described. Various materials and their application to specific types of structures are examined.

  15. Fire-resistant materials for aircraft passenger seat construction

    NASA Technical Reports Server (NTRS)

    Fewell, L. L.; Tesoro, G. C.; Moussa, A.; Kourtides, D. A.

    1979-01-01

    The thermal response characteristics of fabric and fabric-foam assemblies are described. The various aspects of the ignition behavior of contemporary aircraft passenger seat upholstery fabric materials relative to fabric materials made from thermally stable polymers are evaluated. The role of the polymeric foam backing on the thermal response of the fabric-foam assembly is also ascertained. The optimum utilization of improved fire-resistant fabric and foam materials in the construction of aircraft passenger seats is suggested.

  16. 46 CFR 95.17-25 - Additional protection required.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... FIRE PROTECTION EQUIPMENT Foam Extinguishing Systems, Details § 95.17-25 Additional protection required. (a) In order that any residual fires above the floor plates may be extinguished when a foam system is...

  17. 46 CFR 95.17-25 - Additional protection required.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... FIRE PROTECTION EQUIPMENT Foam Extinguishing Systems, Details § 95.17-25 Additional protection required. (a) In order that any residual fires above the floor plates may be extinguished when a foam system is...

  18. STS-30 crewmembers participate in fire fighting training at JSC

    NASA Technical Reports Server (NTRS)

    1989-01-01

    STS-30 Atlantis, Orbiter Vehicle (OV) 104, crewmembers participate in fire fighting training at JSC's fire training pit across from the Gilruth Center Bldg 207. Crewmembers listen to hose and nozzle instructions given by fire / security staff member Robert Fife. Left to right Commander David M. Walker (holding hose nozzle), Mission Specialist (MS) Mark C. Lee, MS Mary L. Cleave, Pilot Ronald J. Grabe, and MS Norman E. Thagard.

  19. Fire Fighting from High Altitude

    NASA Technical Reports Server (NTRS)

    Cobleigh, Brent; Ambrosia, Vince

    2007-01-01

    A viewgraph presentation on high altitude fire fighting is shown. The topics include: 1) Yellowstone Fire - 1988; 2) 2006 Western States Fire Mission Over-View; 3) AMS-Wildfire Scanner; 4) October 24-25 Mission: Yosemite NP and NF; 5) October 24-25 Mission MODIS Overpass; 6) October 24-25 Mission Highlights; 7) October 28-29 Mission Esperanza Fire, California; 8) Response to the Esperanza Fire in Southern California -- Timeline Oct 27-29 2006; 9) October 28-29 Mission Esperanza Fire Altair Flight Routing; 10) October 28-29 Mission Esperanza Fire Altair Over-Flights; 11) October 28-29 Mission Highlights; 12) Results from the Esperanza Fire Response; 13) 2007 Western States Fire Mission; and 14) Western States UAS Fire Mission 2007

  20. 14 CFR 121.106 - ETOPS Alternate Airport: Rescue and fire fighting service.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false ETOPS Alternate Airport: Rescue and fire... and Flag Operations § 121.106 ETOPS Alternate Airport: Rescue and fire fighting service. (a) Except as... available at each airport listed as an ETOPS Alternate Airport in a dispatch or flight release. (1) For...

  1. 14 CFR 121.106 - ETOPS Alternate Airport: Rescue and fire fighting service.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false ETOPS Alternate Airport: Rescue and fire... and Flag Operations § 121.106 ETOPS Alternate Airport: Rescue and fire fighting service. (a) Except as... available at each airport listed as an ETOPS Alternate Airport in a dispatch or flight release. (1) For...

  2. 14 CFR 121.106 - ETOPS Alternate Airport: Rescue and fire fighting service.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false ETOPS Alternate Airport: Rescue and fire... and Flag Operations § 121.106 ETOPS Alternate Airport: Rescue and fire fighting service. (a) Except as... available at each airport listed as an ETOPS Alternate Airport in a dispatch or flight release. (1) For...

  3. 49 CFR 178.358-2 - Materials of construction and other requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Materials of construction and other requirements. (a) Phenolic foam insulation must be fire resistant and... equivalent. (d) Fire-retardant (intumescent) paint must be applied to any wood blocking which is located at... provide pressure relief during the insulation foaming and in the event of a fire. These holes, which must...

  4. 40 CFR Table 3 to Subpart Mmmmm of... - Performance Test Requirements for New or Reconstructed Flame Lamination Affected Sources

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Hazardous Air Pollutants: Flexible Polyurethane Foam Fabrication Operations Pt. 63, Subpt. MMMMM, Table 3... use chlorinated fire retardants in the laminated foam a. Method 26A in appendix A to part 60 of this... chlorinated fire retardants in the laminated foam a. A method approved by the Administrator i. Conduct the...

  5. 40 CFR Table 3 to Subpart Mmmmm of... - Performance Test Requirements for New or Reconstructed Flame Lamination Affected Sources

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Hazardous Air Pollutants: Flexible Polyurethane Foam Fabrication Operations Pt. 63, Subpt. MMMMM, Table 3... use chlorinated fire retardants in the laminated foam a. Method 26A in appendix A to part 60 of this... chlorinated fire retardants in the laminated foam a. A method approved by the Administrator i. Conduct the...

  6. 40 CFR Table 3 to Subpart Mmmmm of... - Performance Test Requirements for New or Reconstructed Flame Lamination Affected Sources

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Hazardous Air Pollutants: Flexible Polyurethane Foam Fabrication Operations Pt. 63, Subpt. MMMMM, Table 3... use chlorinated fire retardants in the laminated foam a. Method 26A in appendix A to part 60 of this... chlorinated fire retardants in the laminated foam a. A method approved by the Administrator i. Conduct the...

  7. 40 CFR Table 3 to Subpart Mmmmm of... - Performance Test Requirements for New or Reconstructed Flame Lamination Affected Sources

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Hazardous Air Pollutants: Flexible Polyurethane Foam Fabrication Operations Pt. 63, Subpt. MMMMM, Table 3... use chlorinated fire retardants in the laminated foam a. Method 26A in appendix A to part 60 of this... chlorinated fire retardants in the laminated foam a. A method approved by the Administrator i. Conduct the...

  8. 40 CFR Table 3 to Subpart Mmmmm of... - Performance Test Requirements for New or Reconstructed Flame Lamination Affected Sources

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Hazardous Air Pollutants: Flexible Polyurethane Foam Fabrication Operations Pt. 63, Subpt. MMMMM, Table 3... use chlorinated fire retardants in the laminated foam a. Method 26A in appendix A to part 60 of this... chlorinated fire retardants in the laminated foam a. A method approved by the Administrator i. Conduct the...

  9. Relative toxicity of pyrolysis products of some polyurethane and polychloroprene foams

    NASA Technical Reports Server (NTRS)

    Hilado, C. J.; Slattengren, C. L.; Kourtides, D. A.; Parker, J. A.

    1977-01-01

    Results of toxicity screening tests on some polyurethane and polychloroprene flexible foams are presented. The test method involves the exposure of four Swiss albino male mice in a 4.2-liter hemispherical chamber to the pyrolysis effluents from 1 g of sample exposed to temperatures rising from 200 to 800 C at a rate of 40 C/min. Mortality and times to incapacitation and to death are recorded. Comparisons indicate that flexible polyurethane foams without fire retardant are more toxic than the corresponding foams containing fire retardant, and polychloroprene foams are least toxic.

  10. Fire Suppression Testing of Hypergolic Vapor Control Foams

    DTIC Science & Technology

    1990-11-01

    tests is given in Table 4. The obstruction test is plotted in Figure 11. c. MIL - F - 24385 -C Tests The low-expansion test utilized in certifying foams for...nozzle, and foam application in accordance with MIL - F -24385C. Extinguishment times were obtained for different application rates. The data were plotted...additional fire tests on the MMH curve. c. MIL - F -24385C Tests A second test (Test A-1B) of this type was conducted with the acrylic-modified foam using

  11. Fire Resistant Composite Closed Cell Foam and Nonwoven Textiles for Tents and Shelters

    DTIC Science & Technology

    2006-01-01

    when heated. The heat causes the plasticizer to dissolve in the PVC to form a flexible, plasticized PVC film . The foam and/or fabric surfaces were...PVC/NBR AF-U9D foam formed a char and only the edge of the material was damaged. These data suggested that burn-through resistance , in addition to...AFRL-ML-TY-TR-2006-4571 FIRE RESISTANT COMPOSITE CLOSED CELL FOAM AND NONWOVEN TEXTILES FOR TENTS AND SHELTERS Stephen C. Davis

  12. Identification of Novel Fluorochemicals in Aqueous Film-Forming Foams (AFFF) Used by the US Military

    PubMed Central

    Place, Benjamin J.; Field, Jennifer A.

    2012-01-01

    Aqueous film-forming foams (AFFFs) are a vital tool to fight large hydrocarbon fires and can be used by public, commercial, and military firefighting organizations. In order to possess these superior firefighting capabilities, AFFFs contain fluorochemical surfactants, of which many of the chemical identities are listed as proprietary. Large-scale controlled (e.g. training activities) and uncontrolled releases of AFFF have resulted in contamination of groundwater. Information on the composition of AFFF formulations is needed to fully define the extent of groundwater contamination and the first step is to fully define the fluorochemical composition of AFFFs used by the US military. Fast atom bombardment mass spectrometry (FAB-MS) and high resolution quadrupole-time-of-flight mass spectrometry (QTOF-MS) were combined to elucidate chemical formulas for the fluorochemicals in AFFF mixtures and, along with patent-based information, structures were assigned. Sample collection and analysis was focused on AFFFs that have been designated as certified for US military use. Ten different fluorochemical classes were identified in the seven military-certified AFFF formulations, and include anionic, cationic, and zwitterionic surfactants with perfluoroalkyl chain lengths ranging from 4-12. The environmental implications are discussed and research needs are identified. PMID:22681548

  13. STS-29 crewmembers participate in fire fighting training at JSC

    NASA Technical Reports Server (NTRS)

    1988-01-01

    STS-29 Discovery, Orbiter Vehicle (OV) 103, crewmembers participate in fire fighting training at JSC's fire training pit across from the Gilruth Center Bldg 207. Mission Specialist (MS) Robert C. Springer (left) and Pilot John E. Blaha, controlling water hose nozzles, approach the blaze and attempt to extinguish it. They are followed by fire / security staff member Robert Fife (between hoses), Commander Michael L. Coats (left), and MS James P. Bagian.

  14. Underground Coal-Fires in Xinjiang, China: A Continued Effort in Applying Geophysics to Solve a Local Problem and to Mitigate a Global Hazard

    NASA Astrophysics Data System (ADS)

    Wuttke, M. W.; Halisch, M.; Tanner, D. C.; Cai, Z. Y.; Zeng, Q.; Wang, C.

    2012-04-01

    Spontaneous uncontrolled coal seam fires are a well known phenomenon that causes severe environmental problems and severe impact on natural coal reserves. Coal fires are a worldwide phenomenon, but in particular in Xinjiang, that covers 17.3 % of Chinas area and hosts approx 42 % of its coal resources. In Xinjiang since more than 50 years a rigorous strategy for fire fighting on local and regional scale is persued. The Xinjiang Coalfield Fire Fighting Bureau (FFB) has developed technologies and methods to deal with any known fire. Many fires have been extinguished already, but the problem is still there if not even growing. This problem is not only a problem for China due to the loss of valuable energy resources, but it is also a worldwide threat because of the generation of substantial amounts of greenhouse gases. Through the FFB, China is struggling to overcome this, but the activities could be much enhanced by the continuation of the already successful conjoint operations. The last ten years have seen two successful cooperative projects between China and Germany on the field of coal-fire fighting, namely the German Technical Cooperation Project on Coal Fire in Xinjiang and the Sino-German Coal Fire Research Initiative funded by the corresponding ministeries of both countries. A persistent task in the fire fighting is the identification and supervision of areas with higher risks for the ignition of coal fires, the exploration of already ignited fire zones to extinguish the fires and the monitoring of extinguished fires to detect as early as possible process that may foster re-ignition. This can be achieved by modeling both the structures and the processes that are involved. This has also been a promising part of the past cooperation projects, yet to be transformed into a standard application of fire fighting procedures. In this contribution we describe the plans for a new conjoint project between China and Germany where on the basis of field investigations and laboratory measurements realistic dynamical models of fire-zones are constructed to increase the understanding of particular coal-fires, to interpret the surface signatures of the coal-fire in terms of location and propagation and to estimate the output of hazardous exhaust products to evaluate the economic benefit of fire extinction.

  15. Polyimide foams provide thermal insulation and fire protection

    NASA Technical Reports Server (NTRS)

    Rosser, R. W.

    1972-01-01

    Chemical reactions to produce polyimide foams for application as thermal insulation and fire prevention materials are discussed. Thermal and physical properties of the polyimides are described. Methods for improving basic formulations to produce desired qualitites are included.

  16. Physiological responses to fire fighting activities.

    PubMed

    Romet, T T; Frim, J

    1987-01-01

    Eight professional fire fighters participated in six fire fighting scenarios at a training facility. Data on heart rate (HR), rectal temperature (Tre), and skin temperatures at the chest and thigh were collected using a portable data acquisition system. Average HR ranged from 122 to 151 beats.min-1 during the six scenarios. Detailed analyses indicated that HR and Tre increases are related to both the physical and environmental stresses of the various activities carried out. The most demanding activity, that of building search and victim rescue, resulted in an average HR of 153 beats.min-1 and Tre rise of 1.3 degree C, while the least demanding activity, that of the crew captain who directs the fire fighting, resulted in an average HR of only 122 beats.min-1 and a Tre rise of only 0.3 degree C. This study shows that fire fighting is strenuous work for those directly entering a building and performing related duties, but that the physical demands of other activities are considerably less. The results further suggest that heat strain injuries in fire fighters could perhaps be reduced by rotating duties frequently with other crew members performing less stressful work.

  17. Fire resistant resilient foams. [for seat cushions

    NASA Technical Reports Server (NTRS)

    Gagliani, J.

    1976-01-01

    Primary program objectives were the formulation, screening, optimization and characterization of open-cell, fire resistant, low-smoke emitting, thermally stable, resilient polyimide foams suitable for seat cushions in commercial aircraft and spacecraft. Secondary program objectives were to obtain maximum improvement of the tension, elongation and tear characteristics of the foams, while maintaining the resiliency, thermal stability, low smoke emission and other desirable attributes of these materials.

  18. 46 CFR 108.473 - Foam system components.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Foam system components. 108.473 Section 108.473 Shipping... EQUIPMENT Fire Extinguishing Systems Foam Extinguishing Systems § 108.473 Foam system components. (a) Each foam agent, each tank for a foam agent, each discharge outlet, each control, and each valve for the...

  19. 46 CFR 108.473 - Foam system components.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Foam system components. 108.473 Section 108.473 Shipping... EQUIPMENT Fire Extinguishing Systems Foam Extinguishing Systems § 108.473 Foam system components. (a) Each foam agent, each tank for a foam agent, each discharge outlet, each control, and each valve for the...

  20. Results of field testing with the FightSight infrared-based projectile tracking and weapon-fire characterization technology

    NASA Astrophysics Data System (ADS)

    Snarski, Steve; Menozzi, Alberico; Sherrill, Todd; Volpe, Chris; Wille, Mark

    2010-04-01

    This paper describes experimental results from recent live-fire data collects that demonstrate the capability of a prototype system for projectile detection and tracking. This system, which is being developed at Applied Research Associates, Inc., under the FightSight program, consists of a high-speed thermal camera and sophisticated image processing algorithms to detect and track projectiles. The FightSight operational vision is automated situational intelligence to detect, track, and graphically map large-scale firefights and individual shooting events onto command and control (C2) systems in real time (shot location and direction, weapon ID, movements and trends). Gaining information on enemy-fire trajectories allows educated inferences on the enemy's intent, disposition, and strength. Our prototype projectile detection and tracking system has been tested at the Joint Readiness Training Center (Ft Polk, LA) during live-fire convoy and mortar registration exercises, in the summer of 2009. It was also tested during staged military-operations- on-urban-terrain (MOUT) firefight events at Aberdeen Test Center (Aberdeen, MD) under the Hostile Fire Defeat Army Technology Objective midterm experiment, also in the summer of 2009, where we introduced fusion with acoustic and EO sensors to provide 3D localization and near-real time display of firing events. Results are presented in this paper that demonstrate effective and accurate detection and localization of weapon fire (5.56mm, 7.62mm, .50cal, 81/120mm mortars, 40mm) in diverse and challenging environments (dust, heat, day and night, rain, arid open terrain, urban clutter). FightSight's operational capabilities demonstrated under these live-fire data collects can support closecombat scenarios. As development continues, FightSight will be able to feed C2 systems with a symbolic map of enemy actions.

  1. STS-32 crewmembers use water hoses during fire fighting training at JSC

    NASA Image and Video Library

    1989-09-22

    STS-32 crewmembers use water hoses during fire fighting exercises at JSC's Fire Training Pit across from the Gilruth Center Bldg 207. Mission Specialist (MS) G. David Low with nozzle open directs water into the fire as fire/ security personnel coaches and instructs him on his attempt to extinguish the blaze. MS Bonnie J. Dunbar maneuvers the hose behind Low. A second group of crewmembers alongside Low and Dunbar, MS Marsha S. Ivins, holding hose nozzle, Commander Daniel C. Brandenstein, and Pilot James D. Wetherbee position themselves before opening hose nozzle.

  2. STS-32 crewmembers use water hoses during fire fighting training at JSC

    NASA Technical Reports Server (NTRS)

    1989-01-01

    STS-32 crewmembers use water hoses during fire fighting exercises at JSC's Fire Training Pit across from the Gilruth Center Bldg 207. Mission Specialist (MS) G. David Low with nozzle open directs water into the fire as fire/ security personnel coaches and instructs him on his attempt to extinguish the blaze. MS Bonnie J. Dunbar maneuvers the hose behind Low. A second group of crewmembers alongside Low and Dunbar, MS Marsha S. Ivins, holding hose nozzle, Commander Daniel C. Brandenstein, and Pilot James D. Wetherbee position themselves before opening hose nozzle.

  3. An empirical test of Lanchester's square law: mortality during battles of the fire ant Solenopsis invicta

    PubMed Central

    Plowes, Nicola J.R; Adams, Eldridge S

    2005-01-01

    Lanchester's models of attrition describe casualty rates during battles between groups as functions of the numbers of individuals and their fighting abilities. Originally developed to describe human warfare, Lanchester's square law has been hypothesized to apply broadly to social animals as well, with important consequences for their aggressive behaviour and social structure. According to the square law, the fighting ability of a group is proportional to the square of the number of individuals, but rises only linearly with fighting ability of individuals within the group. By analyzing mortality rates of fire ants (Solenopsis invicta) fighting in different numerical ratios, we provide the first quantitative test of Lanchester's model for a non-human animal. Casualty rates of fire ants were not consistent with the square law; instead, group fighting ability was an approximately linear function of group size. This implies that the relative numbers of casualties incurred by two fighting groups are not strongly affected by relative group sizes and that battles do not disproportionately favour group size over individual prowess. PMID:16096093

  4. Fiber-modified polyurethane foam for ballistic protection

    NASA Technical Reports Server (NTRS)

    Fish, R. H.; Parker, J. A.; Rosser, R. W.

    1975-01-01

    Closed-cell, semirigid, fiber-loaded, self-extinguishing polyurethane foam material fills voids around fuel cells in aircraft. Material prevents leakage of fuel and spreading of fire in case of ballistic incendiary impact. It also protects fuel cell in case of exterior fire.

  5. Using Space Technologies for a timely detection of forest fires: the experience of end-users in 3 Italian Regions

    NASA Astrophysics Data System (ADS)

    Filizzola, Carolina; Belloni, Antonella; Benigno, Giuseppe; Biancardi, Alberto; Corrado, Rosita; Coviello, Irina; De Costanzo, Giovanni; Genzano, Nicola; Lacava, Teodosio; Lisi, Mariano; Marchese, Francesco; Mazzeo, Giuseppe; Merzagora, Cinzio; Paciello, Rossana; Pergola, Nicola; Sannazzaro, Filomena; Serio, Salvatore; Tramutoli, Valerio

    2013-04-01

    Every year, hundreds of thousands of hectares of European forests are destroyed by fires. Due to the particular topography, landscape and demographic distribution in Europe (very different from typical scenarios of China, USA, Canada and Australia), rapidity in fire sighting is still the determining factor in limiting damages to people and goods. Moreover, the possibility of early fire detection means also potentially to reduce the size of the event to be faced, the necessary fire fighting resources and, therefore, even the reaction times. In such a context, integration of satellite technologies (mainly high temporal resolution data) and traditional surveillance systems within the fire fighting procedures seems to positively impact on the effectiveness of active fire fighting as demonstrated by recent experiences over Italian territory jointly performed by University of Basilicata, IMAA-CNR and Local Authorities. Real time implementation was performed since 2007, during fire seasons, over several Italian regions with different fire regimes and features, in order to assess the actual potential of different satellite-based fire detection products to support regional and local authorities in efficiently fighting fires and better mitigating their negative effects. Real-time campaigns were carried out in strict collaboration with end-users within the framework of specific projects (i.e. the AVVISA, AVVISTA and AVVISA-Basilicata projects) funded by Civil Protection offices of Regione Lombardia, Provincia Regionale di Palermo and Regione Basilicata in charge of fire risk management and mitigation. A tailored training program was dedicated to the personnel of Regional Civil Protection offices in order to ensure the full understanding and the better integration of satellite based products and tools within the existing fire fighting protocols. In this work, outcomes of these practices are shown and discussed, especially highlighting the impact that a real time satellite system may have in assisting and complementing traditional surveillance systems to mitigate damages due to fires. In particular, the usefulness of satellite technology in an operational context was demonstrated mainly in reference to: i) the possibility of identifying fires at an early stage (so avoiding that small hotbeds could extend and become dangerous for citizens and destructive for environmental protected areas) as well as ii) the possibility to have an effective territorial control (e.g. discovering illegal burning fires such as unauthorized cleaning fires, and permitting local authorities to rapidly intervene and catch red-handed pyromaniacs).

  6. 14 CFR 91.815 - Agricultural and fire fighting airplanes: Noise operating limitations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...: Noise operating limitations. 91.815 Section 91.815 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... RULES Operating Noise Limits § 91.815 Agricultural and fire fighting airplanes: Noise operating limitations. (a) This section applies to propeller-driven, small airplanes having standard airworthiness...

  7. Numerical modelling of the work of a pulsed aerosol system for fire fighting at the ignitions of liquid hydrocarbon fuels

    NASA Astrophysics Data System (ADS)

    Rychkov, A. D.

    2009-06-01

    The work of a pulsed aerosol system for fire fighting is modelled, which is designed for fire fighting at oil storages and at the spills of oil products, whose vapors were modelled by gaseous methane. The system represents a device for separate installation, which consists of a charge of solid propellant (the gas generator) and a container with fine-dispersed powder of the flame-damper substance. The methane combustion was described by a one-stage gross-reaction, the influence of the concentration of vapors of the flame-damper substance on the combustion process was taken into account by reducing the pre-exponent factor in the Arrhenius law and was described by an empirical dependence. The computational experiment showed that the application of the pulsed aerosol system for fire fighting ensures an efficient transport of fine-dispersed aerosol particles of the flame-damping substance and its forming vapors to the combustion zone; the concentration of particles ensures the damping of the heat source.

  8. Fire Performance Evaluation of Solid Aqueous Film-Forming Foam (AFFF).

    DTIC Science & Technology

    1986-05-01

    Aqueous Film - Forming Foam ( AFFF ) Concentrates as Firefighting Agents, USAF Report ESL-TR-81-18, Tyndall Air Force Base, Florida...Evaluation of Solid Aqueous Film - Forming Foam ( AFFF ) JOSEPH L. SCHEFFEY HUGHES ASSOCIATES, INC. , EDWIN J. JABLONSKI 2730 UNIVERSITY BLVD. W. JOSEPH T...performance evaluation of the solid agent is the 28-square-foot fire test described in ’L F-24385C, Military Specification for Aqueous Film - Forming

  9. Convective heat transfer in foams under laminar flow in pipes and tube bundles.

    PubMed

    Attia, Joseph A; McKinley, Ian M; Moreno-Magana, David; Pilon, Laurent

    2012-12-01

    The present study reports experimental data and scaling analysis for forced convection of foams and microfoams in laminar flow in circular and rectangular tubes as well as in tube bundles. Foams and microfoams are pseudoplastic (shear thinning) two-phase fluids consisting of tightly packed bubbles with diameters ranging from tens of microns to a few millimeters. They have found applications in separation processes, soil remediation, oil recovery, water treatment, food processes, as well as in fire fighting and in heat exchangers. First, aqueous solutions of surfactant Tween 20 with different concentrations were used to generate microfoams with various porosity, bubble size distribution, and rheological behavior. These different microfoams were flowed in uniformly heated circular tubes of different diameter instrumented with thermocouples. A wide range of heat fluxes and flow rates were explored. Experimental data were compared with analytical and semi-empirical expressions derived and validated for single-phase power-law fluids. These correlations were extended to two-phase foams by defining the Reynolds number based on the effective viscosity and density of microfoams. However, the local Nusselt and Prandtl numbers were defined based on the specific heat and thermal conductivity of water. Indeed, the heated wall was continuously in contact with a film of water controlling convective heat transfer to the microfoams. Overall, good agreement between experimental results and model predictions was obtained for all experimental conditions considered. Finally, the same approach was shown to be also valid for experimental data reported in the literature for laminar forced convection of microfoams in rectangular minichannels and of macrofoams across aligned and staggered tube bundles with constant wall heat flux.

  10. Evaluation of a wearable physiological status monitor during simulated fire fighting activities.

    PubMed

    Smith, Denise L; Haller, Jeannie M; Dolezal, Brett A; Cooper, Christopher B; Fehling, Patricia C

    2014-01-01

    A physiological status monitor (PSM) has been embedded in a fire-resistant shirt. The purpose of this research study was to examine the ability of the PSM-shirt to accurately detect heart rate (HR) and respiratory rate (RR) when worn under structural fire fighting personal protective equipment (PPE) during the performance of various activities relevant to fire fighting. Eleven healthy, college-aged men completed three activities (walking, searching/crawling, and ascending/descending stairs) that are routinely performed during fire fighting operations while wearing the PSM-shirt under structural fire fighting PPE. Heart rate and RR recorded by the PSM-shirt were compared to criterion values measured concurrently with an ECG and portable metabolic measurement system, respectively. For all activities combined (overall) and for each activity, small differences were found between the PSM-shirt and ECG (mean difference [95% CI]: overall: -0.4 beats/min [-0.8, -0.1]; treadmill: -0.4 beats/min [-0.7, -0.1]; search: -1.7 beats/min [-3.1, -.04]; stairs: 0.4 beats/min [0.04, 0.7]). Standard error of the estimate was 3.5 beats/min for all tasks combined and 1.9, 5.9, and 1.9 beats/min for the treadmill walk, search, and stair ascent/descent, respectively. Correlations between the PSM-shirt and criterion heart rates were high (r = 0.95 to r = 0.99). The mean difference between RR recorded by the PSM-shirt and criterion overall was 1.1 breaths/min (95% CI: -1.9 to -0.4). The standard error of the estimate for RR ranged from 4.2 breaths/min (treadmill) to 8.2 breaths/min (search), with an overall value of 6.2 breaths/min. These findings suggest that the PSM-shirt provides valid measures of HR and useful approximations of RR when worn during fire fighting duties.

  11. Development of fire-resistant, low smoke generating, thermally stable end items for commercial aircraft and spacecraft using a basic polyimide resin

    NASA Technical Reports Server (NTRS)

    Gagliani, J.; Lee, R.; Sorathia, U. A.; Wilcoxson, A. L.

    1980-01-01

    A terpolyimide precursor was developed which can be foamed by microwave methods and yields foams possessing the best seating properties. A continuous process, based on spray drying techniques, permits production of polyimide powder precursors in large quantities. The constrained rise foaming process permits fabrication of rigid foam panels with improved mechanical properties and almost unlimited density characteristics. Polyimide foam core rigid panels were produced by this technique with woven fiberglass fabric bonded to each side of the panel in a one step microwave process. The fire resistance of polyimide foams was significantly improved by the addition of ceramic fibers to the powder precursors. Foams produced from these compositions are flexible, possess good acoustical attenuation and meet the minimum burnthrough requirements when impinged by high flux flame sources.

  12. Emergency Management Computer-Aided Trainer (EMCAT)

    NASA Technical Reports Server (NTRS)

    Rodriguez, R. C.; Johnson, R. P.

    1986-01-01

    The Emergency Management Computer-Aided Trainer (EMCAT) developed by Essex Corporation or NASA and the Federal Emergency Management Administration's (FEMA) National Fire Academy (NFA) is described. It is a computer based training system for fire fighting personnel. A prototype EMCAT system was developed by NASA first using video tape images and then video disk images when the technology became available. The EMCAT system is meant to fill the training needs of the fire fighting community with affordable state-of-the-art technologies. An automated real time simulation of the fire situation was needed to replace the outdated manual training methods currently being used. In order to be successful, this simulator had to provide realism, be user friendly, be affordable, and support multiple scenarios. The EMCAT system meets these requirements and therefore represents an innovative training tool, not only for the fire fighting community, but also for the needs of other disciplines.

  13. Capability Portfolio Analysis Tool (CPAT) Verification and Validation Report

    DTIC Science & Technology

    2013-01-01

    BFSB Battlefield Surveillance Brigade BFV Bradley Fighting Vehicle BMOD Bradley Modernization C2 (H) Command and Control (HBCT) C2 (S...Fire Infantry Fighting Vehicle (IFV); Fire Integrated Support Team (FIST); Engineer (Eng); Cavalry (CAV) BFV FOV CDD Block II - 16 Apr 2010 GCV FOV

  14. 14 CFR 36.1583 - Noncomplying agricultural and fire fighting airplanes.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... airplanes. 36.1583 Section 36.1583 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Limitations and Information § 36.1583 Noncomplying agricultural and fire fighting airplanes. (a) This section applies to propeller-driven, small airplanes that— (1) Are designed for “agricultural aircraft operations...

  15. 14 CFR 36.1583 - Noncomplying agricultural and fire fighting airplanes.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... airplanes. 36.1583 Section 36.1583 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Limitations and Information § 36.1583 Noncomplying agricultural and fire fighting airplanes. (a) This section applies to propeller-driven, small airplanes that— (1) Are designed for “agricultural aircraft operations...

  16. 14 CFR 36.1583 - Noncomplying agricultural and fire fighting airplanes.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... airplanes. 36.1583 Section 36.1583 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Limitations and Information § 36.1583 Noncomplying agricultural and fire fighting airplanes. (a) This section applies to propeller-driven, small airplanes that— (1) Are designed for “agricultural aircraft operations...

  17. 14 CFR 36.1583 - Noncomplying agricultural and fire fighting airplanes.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... airplanes. 36.1583 Section 36.1583 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Limitations and Information § 36.1583 Noncomplying agricultural and fire fighting airplanes. (a) This section applies to propeller-driven, small airplanes that— (1) Are designed for “agricultural aircraft operations...

  18. 14 CFR 36.1583 - Noncomplying agricultural and fire fighting airplanes.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... airplanes. 36.1583 Section 36.1583 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Limitations and Information § 36.1583 Noncomplying agricultural and fire fighting airplanes. (a) This section applies to propeller-driven, small airplanes that— (1) Are designed for “agricultural aircraft operations...

  19. Aircraft Carrier Flight Deck Fire Fighting Tactics and Equipment Evaluation Tests

    DTIC Science & Technology

    1987-02-26

    pattern nozzles; 8. proper fire fighting techniques for possible titanium ignition in an F-14 crash (deleted later by direction of FLSC, being studied ...separately); 9. effect of full fire involvement of "ready for flight" aircraft (deleted later by direction of FLSC, being studied separately). The...to refine and identify specific hardware and tactical requirements generated from the studies conducted during the scoping tests; 3. concept

  20. 46 CFR 108.474 - Aqueous film forming foam systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Aqueous film forming foam systems. 108.474 Section 108... DESIGN AND EQUIPMENT Fire Extinguishing Systems Foam Extinguishing Systems § 108.474 Aqueous film forming foam systems. Aqueous film forming foam systems may be installed if approved by the Commandant. ...

  1. 46 CFR 108.474 - Aqueous film forming foam systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Aqueous film forming foam systems. 108.474 Section 108... DESIGN AND EQUIPMENT Fire Extinguishing Systems Foam Extinguishing Systems § 108.474 Aqueous film forming foam systems. Aqueous film forming foam systems may be installed if approved by the Commandant. ...

  2. 46 CFR 108.474 - Aqueous film forming foam systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Aqueous film forming foam systems. 108.474 Section 108... DESIGN AND EQUIPMENT Fire Extinguishing Systems Foam Extinguishing Systems § 108.474 Aqueous film forming foam systems. Aqueous film forming foam systems may be installed if approved by the Commandant. ...

  3. 46 CFR 108.474 - Aqueous film forming foam systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Aqueous film forming foam systems. 108.474 Section 108... DESIGN AND EQUIPMENT Fire Extinguishing Systems Foam Extinguishing Systems § 108.474 Aqueous film forming foam systems. Aqueous film forming foam systems may be installed if approved by the Commandant. ...

  4. 46 CFR 108.474 - Aqueous film forming foam systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Aqueous film forming foam systems. 108.474 Section 108... DESIGN AND EQUIPMENT Fire Extinguishing Systems Foam Extinguishing Systems § 108.474 Aqueous film forming foam systems. Aqueous film forming foam systems may be installed if approved by the Commandant. ...

  5. Rapid growing clay coatings to reduce the fire threat of furniture.

    PubMed

    Kim, Yeon Seok; Li, Yu-Chin; Pitts, William M; Werrel, Martin; Davis, Rick D

    2014-02-12

    Layer-by-layer (LbL) assembly coatings reduce the flammability of textiles and polyurethane foam but require extensive repetitive processing steps to produce the desired coating thickness and nanoparticle fire retardant content that translates into a fire retardant coating. Reported here is a new hybrid bi-layer (BL) approach to fabricate fire retardant coatings on polyurethane foam. Utilizing hydrogen bonding and electrostatic attraction along with the pH adjustment, a fast growing coating with significant fire retardant clay content was achieved. This hybrid BL coating exhibits significant fire performance improvement in both bench scale and real scale tests. Cone calorimetry bench scale tests show a 42% and 71% reduction in peak and average heat release rates, respectively. Real scale furniture mockups constructed using the hybrid LbL coating reduced the peak and average heat release rates by 53% and 63%, respectively. This is the first time that the fire safety in a real scale test has been reported for any LbL technology. This hybrid LbL coating is the fastest approach to develop an effective fire retardant coating for polyurethane foam.

  6. 46 CFR 56.01-10 - Plan approval.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...) Fire extinguishing systems including fire main and sprinkler piping, inert gas and foam. (vi) Bilge and..., I-L, and II-L systems. (ii) All Class II firemain, foam, sprinkler, bilge and ballast, vent sounding... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND APPURTENANCES...

  7. 46 CFR 56.01-10 - Plan approval.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) Fire extinguishing systems including fire main and sprinkler piping, inert gas and foam. (vi) Bilge and..., I-L, and II-L systems. (ii) All Class II firemain, foam, sprinkler, bilge and ballast, vent sounding... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND APPURTENANCES...

  8. 46 CFR 56.01-10 - Plan approval.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) Fire extinguishing systems including fire main and sprinkler piping, inert gas and foam. (vi) Bilge and..., I-L, and II-L systems. (ii) All Class II firemain, foam, sprinkler, bilge and ballast, vent sounding... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND APPURTENANCES...

  9. 46 CFR 56.01-10 - Plan approval.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) Fire extinguishing systems including fire main and sprinkler piping, inert gas and foam. (vi) Bilge and..., I-L, and II-L systems. (ii) All Class II firemain, foam, sprinkler, bilge and ballast, vent sounding... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND APPURTENANCES...

  10. STS-42 crewmembers participate in JSC fire fighting training exercises

    NASA Technical Reports Server (NTRS)

    1991-01-01

    STS-42 Discovery, Orbiter Vehicle (OV) 103, Mission Specialist (MS) Norman E. Thagard, holding hose nozzle, is followed by Payload Specialist Ulf D. Merbold and backup Payload Specialist Kenneth Money as the team positions the water hose in the direction of a blazing fire at JSC's Fire Training Pit. A second team of crewmembers, manning another hose, forms a line parallel to the first. The crewmembers and backups are learning fire extinguishing techniques during fire fighting and fire training exercises held at JSC's Fire Training Pit located across from the Gilruth Center Bldg 207. Merbold is representing the European Space Agency (ESA) during the International Microgravity Laboratory 1 (IML-1) mission aboard OV-103.

  11. A Study of Port Safety Firefighting Requirements.

    DTIC Science & Technology

    1981-08-26

    purposes in massive use, interchangeable, for most purposes, a salt-water compatible AFFF foam agent would be the foam agent of choice. Some fires...capacity of 100 gpm should control 250 ft of fire area in 90 seconds with protein foam and 500 ft with AFFF . Up to some significantly larger fire size...U N S M Z CO O 5§ > H Z fc u 38 en 04 ss h w o 3 o z H o Z w M H CJ b Z O 3 h M H < O 23 «n M 6* •U ’H3i3WVia 3HIJ 149

  12. Solid AFFF Technology Investigation

    DTIC Science & Technology

    2010-12-01

    Aqueous film forming foam, Solid AFFF, MIL - F - 24385 , Foam fire tests, Firefighting handlines, Shipboard fire protection 18. Distribution Statement...28 ft2) fire test in MIL - F -24385F was used as a screening method to determine the viability of the concept. It was determined during this program...military specification for AFFF, MIL - F -24385F, was used as a screening method to determine the viability of the concept. This test has been shown

  13. Materials for fire resistant passenger seats in aircraft

    NASA Technical Reports Server (NTRS)

    Tesoro, G.; Moussa, A.

    1980-01-01

    The paper considers the selection of cushioning foam and upholstery fabric materials for aircraft passenger seats. Polyurethane, polychloroprene, polyimide, and polyphosphazene are the foam materials considered; and a variety of commercial and developmental fabrics (including wool, cotton, synthetics, and blends) are examined. Viable approaches to the design of fire-resistant seat assemblies are indicated. Results of an experimental laboratory study of fabrics and fabric/foam assemblies exposed to external point-source radiative heat flux are discussed.

  14. Preparation for foam composites. [using polybenzimidazole for fireproofing panels

    NASA Technical Reports Server (NTRS)

    Maximovich, M. G.

    1974-01-01

    Methods were developed for the fabrication of fire resistant panels utilizing polybenzimidazole (PBI) and Kerimid 601 resins along with glass, quartz, and Kevlar reinforcements. Stitched truss structure, both unfilled and filled with PBI foam, were successfully fabricated and tested. Second generation structures were then selected, fabricated, and tested, with a PBI/glass skin/PBI foam sandwich structure emerging as the optimum panel concept. Mechanical properties, smoke generation, and fire resistance were determined for the candidate panels.

  15. 29 CFR 1910.159 - Automatic sprinkler systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... supply is out of service, except for systems of 20 or fewer sprinklers. (5) Hose connections for fire fighting use. The employer may attach hose connections for fire fighting use to wet pipe sprinkler systems... 29 Labor 5 2010-07-01 2010-07-01 false Automatic sprinkler systems. 1910.159 Section 1910.159...

  16. 29 CFR 1910.159 - Automatic sprinkler systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... supply is out of service, except for systems of 20 or fewer sprinklers. (5) Hose connections for fire fighting use. The employer may attach hose connections for fire fighting use to wet pipe sprinkler systems... 29 Labor 5 2013-07-01 2013-07-01 false Automatic sprinkler systems. 1910.159 Section 1910.159...

  17. 29 CFR 1910.159 - Automatic sprinkler systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... supply is out of service, except for systems of 20 or fewer sprinklers. (5) Hose connections for fire fighting use. The employer may attach hose connections for fire fighting use to wet pipe sprinkler systems... 29 Labor 5 2014-07-01 2014-07-01 false Automatic sprinkler systems. 1910.159 Section 1910.159...

  18. 29 CFR 1910.159 - Automatic sprinkler systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... supply is out of service, except for systems of 20 or fewer sprinklers. (5) Hose connections for fire fighting use. The employer may attach hose connections for fire fighting use to wet pipe sprinkler systems... 29 Labor 5 2012-07-01 2012-07-01 false Automatic sprinkler systems. 1910.159 Section 1910.159...

  19. 29 CFR 1910.159 - Automatic sprinkler systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... supply is out of service, except for systems of 20 or fewer sprinklers. (5) Hose connections for fire fighting use. The employer may attach hose connections for fire fighting use to wet pipe sprinkler systems... 29 Labor 5 2011-07-01 2011-07-01 false Automatic sprinkler systems. 1910.159 Section 1910.159...

  20. Indicator Systems for School and Teacher Evaluation: Fire-Fighting It Is!

    ERIC Educational Resources Information Center

    Fitz-Gibbon, C. T.

    In 1979, Gene Glass suggested that it might not be possible to evaluate schools nor to create widely applicable research findings, but that the complexity of education was such that merely "fire-fighting," establishing monitoring systems to alert about educational events, was the best approach. In the United Kingdom, monitoring systems…

  1. Evaluation of Two Compressed Air Foam Systems for Culling Caged Layer Hens

    PubMed Central

    Weiher, Jaclyn A.; Alphin, Robert L.; Hougentogler, Daniel P.

    2018-01-01

    Simple Summary Control of avian influenza and similar diseases in commercial poultry operations is challenging; the six major steps are surveillance, biosecurity, quarantine, depopulation, disposal, and cleaning and disinfection. Depopulation is used to cull animals that are terminally ill and to reduce the number of animals that can spread an untreatable disease. Water-based foam depopulation was used effectively during the 2014–2015 highly pathogenic avian influenza outbreak in the United States. Water-based foam, however, cannot be used effectively in caged poultry operations. Compressed air foam systems were initially developed for structural fire-fighting and, with modifications, can provide the conditions required to effectively penetrate a poultry cage and provide sufficient residence time for depopulation. In this experiment, compressed air foam was used to depopulate caged layer hens. Compressed air foam resulted in faster unconsciousness than carbon dioxide gassing. The experiment demonstrated that compressed air foam systems have promise for depopulating birds raised in cages. Abstract Outbreaks of avian influenza (AI) and other highly contagious poultry diseases continue to be a concern for those involved in the poultry industry. In the situation of an outbreak, emergency depopulation of the birds involved is necessary. In this project, two compressed air foam systems (CAFS) were evaluated for mass emergency depopulation of layer hens in a manure belt equipped cage system. In both experiments, a randomized block design was used with multiple commercial layer hens treated with one of three randomly selected depopulation methods: CAFS, CAFS with CO2 gas, and CO2 gas. In Experiment 1, a Rowe manufactured CAFS was used, a selection of birds were instrumented, and the time to unconsciousness, brain death, altered terminal cardiac activity and motion cessation were recorded. CAFS with and without CO2 was faster to unconsciousness, however, the other parameters were not statistically significant. In Experiment 2, a custom Hale based CAFS was used to evaluate the impact of bird age, a selection of birds were instrumented, and the time to motion cessation was recorded. The difference in time to cessation of movement between pullets and spent hens using CAFS was not statistically significant. Both CAFS depopulate caged layers, however, there was no benefit to including CO2. PMID:29695072

  2. Three-dimensional tracking for efficient fire fighting in complex situations

    NASA Astrophysics Data System (ADS)

    Akhloufi, Moulay; Rossi, Lucile

    2009-05-01

    Each year, hundred millions hectares of forests burn causing human and economic losses. For efficient fire fighting, the personnel in the ground need tools permitting the prediction of fire front propagation. In this work, we present a new technique for automatically tracking fire spread in three-dimensional space. The proposed approach uses a stereo system to extract a 3D shape from fire images. A new segmentation technique is proposed and permits the extraction of fire regions in complex unstructured scenes. It works in the visible spectrum and combines information extracted from YUV and RGB color spaces. Unlike other techniques, our algorithm does not require previous knowledge about the scene. The resulting fire regions are classified into different homogenous zones using clustering techniques. Contours are then extracted and a feature detection algorithm is used to detect interest points like local maxima and corners. Extracted points from stereo images are then used to compute the 3D shape of the fire front. The resulting data permits to build the fire volume. The final model is used to compute important spatial and temporal fire characteristics like: spread dynamics, local orientation, heading direction, etc. Tests conducted on the ground show the efficiency of the proposed scheme. This scheme is being integrated with a fire spread mathematical model in order to predict and anticipate the fire behaviour during fire fighting. Also of interest to fire-fighters, is the proposed automatic segmentation technique that can be used in early detection of fire in complex scenes.

  3. Fight Fire Without Fire Fighters!

    ERIC Educational Resources Information Center

    Peacock, Richard D.

    1977-01-01

    There is a role for the classroom teacher in teaching fire safety. Discusses the inadequacies of present fire prevention programs and provides ten specific steps teachers can take to avoid suffering and death from fire. (Author/RK)

  4. 46 CFR 108.467 - Water supply.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Water supply. 108.467 Section 108.467 Shipping COAST... Fire Extinguishing Systems Foam Extinguishing Systems § 108.467 Water supply. The water supply of a foam extinguishing system must not be the water supply of the fire main system on the unit unless when...

  5. 46 CFR 108.467 - Water supply.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Water supply. 108.467 Section 108.467 Shipping COAST... Fire Extinguishing Systems Foam Extinguishing Systems § 108.467 Water supply. The water supply of a foam extinguishing system must not be the water supply of the fire main system on the unit unless when...

  6. 29 CFR Appendix C to Subpart L of... - Fire Protection References For Further Information

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...—September 30, 1978. Evaluation and Performance of Open Circuit Breathing Apparatus. NU REG/CR-1235. Los.... § 1910.160. Fixed extinguishing systems—general information: 1. Standard for Foam Extinguishing Systems... for Hi-Expansion Foam Systems, ANSI/NFPA 11A; National Fire Protection Association, Batterymarch Park...

  7. 46 CFR 108.467 - Water supply.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Water supply. 108.467 Section 108.467 Shipping COAST... Fire Extinguishing Systems Foam Extinguishing Systems § 108.467 Water supply. The water supply of a foam extinguishing system must not be the water supply of the fire main system on the unit unless when...

  8. 46 CFR 108.467 - Water supply.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Water supply. 108.467 Section 108.467 Shipping COAST... Fire Extinguishing Systems Foam Extinguishing Systems § 108.467 Water supply. The water supply of a foam extinguishing system must not be the water supply of the fire main system on the unit unless when...

  9. 46 CFR 108.467 - Water supply.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Water supply. 108.467 Section 108.467 Shipping COAST... Fire Extinguishing Systems Foam Extinguishing Systems § 108.467 Water supply. The water supply of a foam extinguishing system must not be the water supply of the fire main system on the unit unless when...

  10. 29 CFR 1910.163 - Fixed extinguishing systems, water spray and foam.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 5 2013-07-01 2013-07-01 false Fixed extinguishing systems, water spray and foam. 1910.163 Section 1910.163 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR OCCUPATIONAL SAFETY AND HEALTH STANDARDS Fire Protection Fixed Fire Suppression Equipment § 1910.163 Fixed...

  11. 30 CFR 75.1101-5 - Installation of foam generator systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... (b) Foam generator systems shall be equipped with a fire sensor which actuates the system, and each.... (d) Water, power, and chemicals required shall be adequate to maintain water or foam flow for no less...

  12. 30 CFR 75.1101-5 - Installation of foam generator systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... (b) Foam generator systems shall be equipped with a fire sensor which actuates the system, and each.... (d) Water, power, and chemicals required shall be adequate to maintain water or foam flow for no less...

  13. 30 CFR 75.1101-5 - Installation of foam generator systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... (b) Foam generator systems shall be equipped with a fire sensor which actuates the system, and each.... (d) Water, power, and chemicals required shall be adequate to maintain water or foam flow for no less...

  14. High Expansion Foam for Protecting Large Volume Mission Critical Shipboard Spaces

    DTIC Science & Technology

    2009-01-01

    aqueous film - forming foam ( AFFF ) sprinklers designed only to combat Class B two-dimensional pool fires.1 The...Validation Tests, Series 1 – An Evaluation of Aqueous Film Foaming Foam ( AFFF ) Suppression Systems for Protection of LHA(R) Well Deck and Vehicle... firefighting system design. NRL further recognized that employing a traditional high expansion foam generator would impact shipboard

  15. NoFoam Unit Installation, Evaluation and Operations Manual

    DTIC Science & Technology

    2003-03-10

    Aqueous Film Forming Foam ( AFFF ) liquid concentrate in their fleet do not have the facilities...NoFoam Unit using AFRL vehicles and facilities. Currently, the majority of Fire Departments that use 3% Aqueous Film Forming Foam ( AFFF ) liquid...Departments that have ARFF vehicles that use 3% Aqueous Film Forming Foam ( AFFF ) liquid concentrate in their fleet do not have the facilities

  16. Sticky foam as a less-than-lethal technology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scott, S.H.

    1996-12-31

    Sandia National Labs (SNL) in 1994 completed a project funded by the National Institute of Justice (NIJ) to determine the applicability of sticky foam for correctional applications. Sticky foam is an extremely tacky, tenacious material used to block, entangle, and impair individuals. The NIJ project developed a gun capable of firing multiple shots of sticky foam, tested the gun and sticky foam effectiveness on SNL volunteers acting out prison and law enforcement scenarios, and had the gun and sticky foam evaluated by correctional representatives. Based on the NIJ project work, SNL supported the Marine Corps Mission, Operation United Shield, withmore » sticky foam guns and supporting equipment to assist in the withdrawal of UN Peacekeepers from Somalia. Prior to the loan of the equipment, the Marines were given training in sticky foam characterization, toxicology, safety issues, cleanup and waste disposal, use limitations, use protocol and precautions, emergency facial clean-up, skin cleanup, gun filling, targeting and firing, and gun cleaning. The Marine Corps successfully used the sticky foam guns as part of that operation. This paper describes these recent developments of sticky foam for non-lethal uses and some of the lessons learned from scenario and application testing.« less

  17. Research in fire prevention.

    PubMed

    Pearce, N

    1985-10-01

    This paper describes in broad terms, the fire testing programme we carried out on whole bed assemblies in 1984. It should be clear that the tests were carried out in a thoroughly rigorous scientific manner. As always there is more to be done. The immediate task of finding the so called 'safe' bed assembly is proceeding with the search this year for safer pillows. Softer barrier foams are now being produced and it may be that the NHS could use full depth foam mattresses rather than a barrier foam wrap. On the engineering side I have explained the false alarm problem, and I have reviewed some of the research we are doing to see that new technology is used to give us better systems in future. Life safety sprinkler systems give the possibility of truly active fire protection in patient areas. They will enhance fire safety but at the moment no trade-offs can be offered in other areas of fire protection--either active or passive. My final point is that although I have considered the Department's fire research by looking separately at specific projects, the fire safety of a hospital must always be considered as a total package. To be effective, individual components of fire safety must not be considered in isolation but as part of the overall fire safety system.

  18. Consequences of Fire: The Killing Fumes

    MedlinePlus

    ... Electric Vehicles Fire Fighter Safety and Response for Solar Power Systems Fire Fighting Tactics Under Wind Driven ... Protection Devices Development of Fire Mitigations Solutions for PV Systems Installed on Building Roofs - Phase 1 Electric/ ...

  19. Effect of an uncontrolled fire and the subsequent fire fight on the chemical composition of landfill leachate.

    PubMed

    Oygard, Joar Karsten; Måge, Amund; Gjengedal, Elin; Svane, Tore

    2005-01-01

    Landfill leachates sampled during and after an accidental landfill fire were analysed and the levels of selected metals and chemical compounds compared to those occurring in the leachate under normal conditions. The fire at the landfill site was put out by excavation and cooling by use of water. The investigation during the fire and fire fight revealed a moderate increase in the level of nitrogen and also in pH and conductivity. Heavy metals and COD in the leachate showed considerably increased levels. In general, the determined variables appeared to normalise within one week after the fire was extinguished. It can be concluded that landfill fires extinguished by excavation may lead to elevated leachate levels of especially COD and heavy metals, but that this is only a short-term effect.

  20. The simulation of surface fire spread based on Rothermel model in windthrow area of Changbai Mountain (Jilin, China)

    NASA Astrophysics Data System (ADS)

    Yin, Hang; Jin, Hui; Zhao, Ying; Fan, Yuguang; Qin, Liwu; Chen, Qinghong; Huang, Liya; Jia, Xiang; Liu, Lijie; Dai, Yuhong; Xiao, Ying

    2018-03-01

    The forest-fire not only brings great loss to natural resources, but also destructs the ecosystem and reduces the soil fertility, causing some natural disasters as soil erosion and debris flow. However, due to the lack of the prognosis for forest fire spreading trend in forest fire fighting, it is difficult to formulate rational and effective fire-fighting scheme. In the event of forest fire, achieving accurate judgment to the fire behavior would greatly improve the fire-fighting efficiency, and reduce heavy losses caused by fire. Researches on forest fire spread simulation can effectively reduce the loss of disasters. The present study focused on the simulation of "29 May 2012" wildfire in windthrow area of Changbai Mountain. Basic data were retrieved from the "29 May 2012" wildfire and field survey. A self-development forest fire behavior simulated program based on Rothermel Model was used in the simulation. Kappa coefficient and Sørensen index were employed to evaluate the simulation accuracy. The results showed that: The perimeter of simulated burned area was 4.66 km, the area was 56.47 hm2 and the overlapped burned area was 33.68 hm2, and the estimated rate of fire spread was 0.259 m/s. Between the simulated fire and actual fire, the Kappa coefficient was 0.7398 and the Sørensen co-efficient was 0.7419. This proved the application of Rothermel model to conduct fire behavior simulation in windthrow meadow was feasible. It can achieve the goal of forecasting for the spread behavior in windthrow area of Changbai Mountain. Thus, our self-development program based on the Rothermel model can provide a effective forecast of fire spread, which will facilitate the fire suppression work.

  1. Experimental characterization of fire-induced response of rigid polyurethane foam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chu, T.Y.; Gill, W.; Moore, J.W.

    1995-12-31

    Reported is the result of an experimental investigation of fire-induced response of a 96 kg/m{sup 3} closed cell rigid polyurethane foam. The specimen is 0.37 m in diameter, and 152 mm thick, placed in a cylindrical test vessel. The fire condition is simulated by heating the bottom of the test vessel to 1283 K using a radiant heat source. Real-time x-ray shows that the degradation process involves the progression of a charring front into the virgin material. The charred region has a regular and graded structure consisting of a packed bubble outer layer and successive layers of thin shells. Themore » layer-to-layer permeability appears to be poor. There are indications that gas vents laterally. The shell-like structure might be the result of lateral venting. Although the foam degradation process is quite complicated, the in-depth temperature responses in the uncharted foam appear to be consistent with steady state ablation. The measured temperature responses are well represented by the exponential distribution for steady state ablation. An estimate of the thermal diffusivity of the foam is obtained from the ablation model. The experiment is part of a more comprehensive program to develop material response models of foams and encapsulants.« less

  2. Estimating suppression expenditures for individual large wildland fires

    Treesearch

    Krista M. Gebert; David E. Calkin; Jonathan Yoder

    2007-01-01

    The extreme cost of fighting wildland fires has brought fire suppression expenditures to the forefront of budgetary and policy debate in the United States. Inasmuch as large fires are responsible for the bulk of fire suppression expenditures, understanding fire characteristics that influence expenditures is important for both strategic fire planning and onsite fire...

  3. Fire and the Design of Educational Buildings. Building Bulletin 7. Sixth Edition.

    ERIC Educational Resources Information Center

    Department of Education and Science, London (England).

    This bulletin offers guidance on English school premises regulations applying to safety protection against fires in the following general areas: means of escape in case of fire; precautionary measures to prevent fire; fire warning systems and fire fighting; fire spreading speed; structures and materials resistant to fires; and damage control. It…

  4. Organic-inorganic hybrid foams with diatomite addition: Effect on functional properties

    NASA Astrophysics Data System (ADS)

    Verdolotti, L.; D'Auria, M.; Lavorgna, M.; Vollaro, P.; Iannace, S.; Capasso, I.; Galzerano, B.; Caputo, D.; Liguori, B.

    2016-05-01

    Organic-inorganic hybrid foams were prepared by using metakaolin, diatomite as a partial (or total) replacement of metakaolin, as matrix, silicon and whipped protein as pore forming. The foamed systems were hardened at defined temperature and time and then characterized by mechanical point of view through compression tests and by functional point of view through fire reaction and acoustic tests. The experimental findings highlighted that the replacement of diatomite in the formulation affected the morphological structure of the foams and consequently their mechanical properties. In particular, the consolidation mechanism in the diatomite based-hybrid foams changed from geopolymerization to a silicate polycondensation mechanism. Therefore, mechanical performances enhanced with increasing of the diatomite content. Fire reaction tests, such as non-combustibility and cone calorimeter tests, showed positive thermal inertia of samples regardless of the content of diatomite.

  5. STS-47 crew during JSC fire fighting exercises in the Fire Training Pit

    NASA Technical Reports Server (NTRS)

    1992-01-01

    STS-47 Endeavour, Orbiter Vehicle (OV) 105, crewmembers line up along water hoses during JSC fire fighting exercises held at JSC's Fire Training Pit. In the foreground are (left to right) Pilot Curtis L. Brown, Jr, holding the hose nozzle, Mission Specialist (MS) N. Jan Davis, MS and Payload Commander (PLC) Mark C. Lee, and backup Payload Specialist Stan Koszelak, partially visible at the end of the line. In the background, manning a second hose are backup Payload Specialist Takao Doi, MS Jerome Apt, and Commander Robert L. Gibson. A veteran fire fighter (behind Brown) stands between the two hoses giving instructions. The Fire Training Pit is located across from the Gilruth Center Bldg 207. Doi represents Japan's National Space Development Agency (NASDA).

  6. Applying Open Source Game Engine for Building Visual Simulation Training System of Fire Fighting

    NASA Astrophysics Data System (ADS)

    Yuan, Diping; Jin, Xuesheng; Zhang, Jin; Han, Dong

    There's a growing need for fire departments to adopt a safe and fair method of training to ensure that the firefighting commander is in a position to manage a fire incident. Visual simulation training systems, with their ability to replicate and interact with virtual fire scenarios through the use of computer graphics or VR, become an effective and efficient method for fire ground education. This paper describes the system architecture and functions of a visual simulated training system of fire fighting on oil storage, which adopting Delat3D, a open source game and simulation engine, to provide realistic 3D views. It presents that using open source technology provides not only the commercial-level 3D effects but also a great reduction of cost.

  7. Monitoring system of multiple fire fighting based on computer vision

    NASA Astrophysics Data System (ADS)

    Li, Jinlong; Wang, Li; Gao, Xiaorong; Wang, Zeyong; Zhao, Quanke

    2010-10-01

    With the high demand of fire control in spacious buildings, computer vision is playing a more and more important role. This paper presents a new monitoring system of multiple fire fighting based on computer vision and color detection. This system can adjust to the fire position and then extinguish the fire by itself. In this paper, the system structure, working principle, fire orientation, hydrant's angle adjusting and system calibration are described in detail; also the design of relevant hardware and software is introduced. At the same time, the principle and process of color detection and image processing are given as well. The system runs well in the test, and it has high reliability, low cost, and easy nodeexpanding, which has a bright prospect of application and popularization.

  8. 30 CFR 75.1101 - Deluge-type water sprays, foam generators; main and secondary belt-conveyor drives.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Deluge-type water sprays, foam generators; main... Fire Protection § 75.1101 Deluge-type water sprays, foam generators; main and secondary belt-conveyor drives. [Statutory Provisions] Deluge-type water sprays or foam generators automatically actuated by rise...

  9. 30 CFR 75.1101 - Deluge-type water sprays, foam generators; main and secondary belt-conveyor drives.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Deluge-type water sprays, foam generators; main... Fire Protection § 75.1101 Deluge-type water sprays, foam generators; main and secondary belt-conveyor drives. [Statutory Provisions] Deluge-type water sprays or foam generators automatically actuated by rise...

  10. EXTINGUISHMENT OF ALKALI METAL FIRES

    DTIC Science & Technology

    low O2 partial pressures on alkali metal fires Extinguishment of alkali metal fires using in organic salt mixtures Extinguishment of alkali metal ... fires using inorganic salt foams Alkali metal jet stream ignition at various pressure conditions Bibliography

  11. Use of class a foams on structures and wildlands

    Treesearch

    Paul Schlobohm

    1995-01-01

    The increase of homes in wildlands indicates a significant change. The build-up of fuels around homes and in wildlands over time also indicates change. Resistance to change, however, remains the norm. Fires get worse, but plain water continues to be used for fire suppression and property protection. With Class A foam, the objectives of protection are to wet the...

  12. Fire protection for a Martian colony

    NASA Astrophysics Data System (ADS)

    Beattie, Robert M., Jr.

    The fire prevention failures that occurred in Apollo 1 and Challenger accidents are reviewed and used to discuss fire protection measures that should be taken in a Martian colony. Fire detection systems, classes of fire, and suppression agents are described. The organization of fire fighting personnel appropriate for Mars is addressed.

  13. Fire Control Agent Effectiveness for Hazardous Chemical Fires: Carbon Disulfide.

    DTIC Science & Technology

    1981-01-01

    Fires..................................... 46 12. AFFF Fire Control Data for Carbon Disulfide Fires............................. 47 13. Extinguishment...Disulfide and Hexane Fires ....... 67 22. Comparison of AFFF Fire Control Times for Carbon Disulfide and Hexane Fires ................... 68 23. Comparison of...Data .............. 27 2. Summary of Fluoroprotein Foam Fire Test Data ....... 28 3. Summary of AFFF Fire Test Data ..................... 29 4. Summary

  14. Training Fires on Indian Reservations in Idaho, Oregon, and Washington

    EPA Pesticide Factsheets

    The Federal Air Rules for Reservations (FARR) Open Burning Rule allows Fire Protection Services to request permission from EPA to conduct an outdoor burn by qualified personnel to train firefighters on fire suppression and fire fighting techniques.

  15. Multi-Level Wild Land Fire Fighting Management Support System for an Optimized Guidance of Ground and Air Forces

    NASA Astrophysics Data System (ADS)

    Almer, Alexander; Schnabel, Thomas; Perko, Roland; Raggam, Johann; Köfler, Armin; Feischl, Richard

    2016-04-01

    Climate change will lead to a dramatic increase in damage from forest fires in Europe by the end of this century. In the Mediterranean region, the average annual area affected by forest fires has quadrupled since the 1960s (WWF, 2012). The number of forest fires is also on the increase in Central and Northern Europe. The Austrian forest fire database shows a total of 584 fires for the period 2012 to 2014, while even large areas of Sweden were hit by forest fires in August 2014, which were brought under control only after two weeks of intense fire-fighting efforts supported by European civil protection modules. Based on these facts, the improvements in forest fire control are a major international issue in the quest to protect human lives and resources as well as to reduce the negative environmental impact of these fires to a minimum. Within this paper the development of a multi-functional airborne management support system within the frame of the Austrian national safety and security research programme (KIRAS) is described. The main goal of the developments is to assist crisis management tasks of civil emergency teams and armed forces in disaster management by providing multi spectral, near real-time airborne image data products. As time, flexibility and reliability as well as objective information are crucial aspects in emergency management, the used components are tailored to meet these requirements. An airborne multi-functional management support system was developed as part of the national funded project AIRWATCH, which enables real-time monitoring of natural disasters based on optical and thermal images. Airborne image acquisition, a broadband line of sight downlink and near real-time processing solutions allow the generation of an up-to-date geo-referenced situation map. Furthermore, this paper presents ongoing developments for innovative extensions and research activities designed to optimize command operations in national and international fire-fighting missions. The ongoing development focuses on the following topics: (1) Development of a multi-level management solution to coordinate and guide different airborne and terrestrial deployed firefighting modules as well as related data processing and data distribution activities. (2) Further, a targeted control of the thermal sensor based on a rotating mirror system to extend the "area performance" (covered area per hour) in time critical situations for the monitoring requirements during forest fire events. (3) Novel computer vision methods for analysis of thermal sensor signatures, which allow an automatic classification of different forest fire types and situations. (4) A module for simulation-based decision support for planning and evaluation of resource usage and the effectiveness of performed fire-fighting measures. (5) Integration of wearable systems to assist ground teams in rescue operations as well as a mobile information system into innovative command and fire-fighting vehicles. In addition, the paper gives an outlook on future perspectives including a first concept for the integration of the near real-time multilevel forest fire fighting management system into an "EU Civil Protection Team" to support the EU civil protection modules and the Emergency Response Coordination Centre in Brussels. Keywords: Airborne sensing, multi sensor imaging, near real-time fire monitoring, simulation-based decision support, forest firefighting management, firefighting impact analysis.

  16. EXTINGUISHMENT OF ALKALI METAL FIRES

    DTIC Science & Technology

    Contents: Effect of inert gas nket and ow O2 partial pressures on alkali metal fires Extinguishment of small scale fires Extinguishment of alkali... metal fires using inorganic salt foam Alkali metal jet stream ignition at various pressure conditions

  17. Limitations imposed on fire PRA methods as the result of incomplete and uncertain fire event data.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nowlen, Steven Patrick; Hyslop, J. S.

    2010-04-01

    Fire probabilistic risk assessment (PRA) methods utilize data and insights gained from actual fire events in a variety of ways. For example, fire occurrence frequencies, manual fire fighting effectiveness and timing, and the distribution of fire events by fire source and plant location are all based directly on the historical experience base. Other factors are either derived indirectly or supported qualitatively based on insights from the event data. These factors include the general nature and intensity of plant fires, insights into operator performance, and insights into fire growth and damage behaviors. This paper will discuss the potential methodology improvements thatmore » could be realized if more complete fire event reporting information were available. Areas that could benefit from more complete event reporting that will be discussed in the paper include fire event frequency analysis, analysis of fire detection and suppression system performance including incipient detection systems, analysis of manual fire fighting performance, treatment of fire growth from incipient stages to fully-involved fires, operator response to fire events, the impact of smoke on plant operations and equipment, and the impact of fire-induced cable failures on plant electrical circuits.« less

  18. The effect of changes in the USF/NASA toxicity screening test method on data from some cellular polymers

    NASA Technical Reports Server (NTRS)

    Hilado, C. J.; Miller, C. M.

    1976-01-01

    Rankings of relative toxicity can be markedly affected by changes in test variables. Revision of the USF/NASA toxicity screening test procedure to eliminate the connecting tube and supporting floor and incorporate a 1.0 g sample weight, 200 C starting temperature, and 800 C upper limit temperature for pyrolysis, reversed the rankings of flexible polyurethane and polychloroprene foams, not only in relation to each other, but also in relation to cotton and red oak. Much of the change is attributed to reduction of the distance between the sample and the test animals, and reduction of the sample weight charged. Elimination of the connecting tube increased the relative toxicity of the polyurethane foams. The materials tested were flexible polyurethane foam, without and with fire retardant; rigid polyurethane foam with fire retardant; flexible polychloroprene foam; cotton, Douglas fir, red oak, hemlock, hardboard, particle board, polystyrene, and polymethyl methacrylate.

  19. 29 CFR 1926.155 - Definitions applicable to this subpart.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... part, fire resistance shall be determined by the Standard Methods of Fire Tests of Building... knowledgeable, trained, and skilled in the safe evacuation of employees during emergency situations and in assisting in fire fighting operations. (f) Fire resistance means so resistant to fire that, for specified...

  20. 29 CFR 1926.155 - Definitions applicable to this subpart.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... part, fire resistance shall be determined by the Standard Methods of Fire Tests of Building... knowledgeable, trained, and skilled in the safe evacuation of employees during emergency situations and in assisting in fire fighting operations. (f) Fire resistance means so resistant to fire that, for specified...

  1. 29 CFR 1926.155 - Definitions applicable to this subpart.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... part, fire resistance shall be determined by the Standard Methods of Fire Tests of Building... knowledgeable, trained, and skilled in the safe evacuation of employees during emergency situations and in assisting in fire fighting operations. (f) Fire resistance means so resistant to fire that, for specified...

  2. 29 CFR 1926.155 - Definitions applicable to this subpart.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... part, fire resistance shall be determined by the Standard Methods of Fire Tests of Building... knowledgeable, trained, and skilled in the safe evacuation of employees during emergency situations and in assisting in fire fighting operations. (f) Fire resistance means so resistant to fire that, for specified...

  3. 29 CFR 1926.155 - Definitions applicable to this subpart.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... part, fire resistance shall be determined by the Standard Methods of Fire Tests of Building... knowledgeable, trained, and skilled in the safe evacuation of employees during emergency situations and in assisting in fire fighting operations. (f) Fire resistance means so resistant to fire that, for specified...

  4. Damage Caused to Polyurethane Foams by Aging, Simulated Sunlight Exposure, Heat and Fire

    DTIC Science & Technology

    1984-07-01

    vented configuration ............ .................. 11 4 Sample of the tan-colored solid formed upon pyrolysis of blue foam ..... .............. .. 21...54 26 Infrared absorption spectrum of the solid, tan-colored pyrolysis product formed from blue polyurethane foam ..... .............. .. 55 27...Infrared absorption spectrum of the liquid, brown-colored pyrolysis product formed from blue polyurethane foam ..... .............. .. 56 28 Fuel vent

  5. 46 CFR 162.028-5 - Independent laboratories: Listing.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... MATERIALS: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Extinguishers, Fire, Portable, Marine Type... or tests of portable fire extinguishers: (a) For dry chemical, CO2, water and foam type portable fire...

  6. 46 CFR 162.028-5 - Independent laboratories: Listing.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... MATERIALS: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Extinguishers, Fire, Portable, Marine Type... or tests of portable fire extinguishers: (a) For dry chemical, CO2, water and foam type portable fire...

  7. 46 CFR 162.028-5 - Independent laboratories: Listing.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... MATERIALS: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Extinguishers, Fire, Portable, Marine Type... or tests of portable fire extinguishers: (a) For dry chemical, CO2, water and foam type portable fire...

  8. 46 CFR 162.028-5 - Independent laboratories: Listing.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... MATERIALS: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Extinguishers, Fire, Portable, Marine Type... or tests of portable fire extinguishers: (a) For dry chemical, CO2, water and foam type portable fire...

  9. 46 CFR 162.028-5 - Independent laboratories: Listing.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... MATERIALS: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Extinguishers, Fire, Portable, Marine Type... or tests of portable fire extinguishers: (a) For dry chemical, CO2, water and foam type portable fire...

  10. The Corrosion of Metals in Aqueous Film-Forming Foams.

    DTIC Science & Technology

    CORROSION), (*FIRE EXTINGUISHERS, STAINLESS STEEL), (*STAINLESS STEEL, (* FOAM , CORROSION), PH FACTOR, CHLORIDES, FLUORIDES, STEEL, NICKEL ALLOYS, COPPER ALLOYS, NAVAL EQUIPMENT, AIRCRAFT CARRIERS, SEA WATER, COMPATIBILITY.

  11. The effect of smoke inhalation on lung function and airway responsiveness in wildland fire fighters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, D.; Tager, I.B.; Balmes, J.R.

    1992-12-01

    The current study was undertaken to evaluate the effect of smoke on forced expiratory volumes and airway responsiveness in wildland fire fighters during a season of active fire fighting. Sixty-three seasonal and full-time wildland fire fighters from five U.S. Department of Agriculture Forest Service (USDAFS) Hotshot crews in Northern California and Montana completed questionnaires, spirometry, and methacholine challenge testing before and after an active season of fire fighting in 1989. There were significant mean individual declines of 0.09, 0.15, and 0.44 L/s in postseason values of FVC, FEV1, and FEF25-75, respectively, compared with preseason values. There were no consistent significantmore » relationships between mean individual declines of the spirometric parameters and the covariates: sex, smoking history, history of asthma or allergies, years as a fire fighter, upper/lower respiratory symptoms, or membership in a particular Hotshot crew. There was a statistically significant increase in airway responsiveness when comparing preseason methacholine dose-response slopes (DRS) with postseason dose-response slopes (p = 0.02). The increase in airway responsiveness appeared to be greatest in fire fighters with a history of lower respiratory symptoms or asthma, but it was not related to smoking history. These data suggest that wildland fire fighting is associated with decreases in lung function and increases in airway responsiveness independent of a history of cigarette smoking. Our findings are consistent with the results of previous studies of municipal fire fighters.« less

  12. Full-scale flammability test data for validation of aircraft fire mathematical models

    NASA Technical Reports Server (NTRS)

    Kuminecz, J. F.; Bricker, R. W.

    1982-01-01

    Twenty-five large scale aircraft flammability tests were conducted in a Boeing 737 fuselage at the NASA Johnson Space Center (JSC). The objective of this test program was to provide a data base on the propagation of large scale aircraft fires to support the validation of aircraft fire mathematical models. Variables in the test program included cabin volume, amount of fuel, fuel pan area, fire location, airflow rate, and cabin materials. A number of tests were conducted with jet A-1 fuel only, while others were conducted with various Boeing 747 type cabin materials. These included urethane foam seats, passenger service units, stowage bins, and wall and ceiling panels. Two tests were also included using special urethane foam and polyimide foam seats. Tests were conducted with each cabin material individually, with various combinations of these materials, and finally, with all materials in the cabin. The data include information obtained from approximately 160 locations inside the fuselage.

  13. Acute toxicity of fire-retardant and foam-suppressant chemicals to early life stages of chinook salmon (Oncorhynchus tshawytscha)

    USGS Publications Warehouse

    Buhl, Kevin J.; Hamilton, Steven J.

    1998-01-01

    Laboratorys studies were conducted to determine the acute toxicity of three fire retardants (Fire-Trol GTS-R, Fire-Trol LCG-R, and Phos-Chek D75-F), and two fire-suppressant foams (Phos-Chek WD-881 and Ansul Silv-Ex) to early life stages of chinook salmon, Oncorhynchus tshawytscha, in hard and soft water. Regardless of water type, swim-up fry and juveniles (60 and 90 d posthatch) exhibited similar sensitivities to each chemical and these life stages were more sensitive than eyed eggs. Foam suppressants were more toxic to each life stage than the fire retardants in both water types. The descending rank order of toxicity for these chemicals tested with swim-up fry and juveniles (range of 96-h median lethal concentrations [LC50s]) was Phos-Chek WD-881 (7–13 mg/L) > Ansul Silv-Ex (11–22 mg/L) > Phos-Chek D75-F (218–305 mg/L) > Fire-Trol GTS-R (218–412 mg/L) > Fire-Trol LCG-R (685–1,195 mg/L). Water type had a minor effect on the toxicity of these chemicals. Comparison of acute toxicity values with recommended application concentrations indicates that accidental inputs of these chemicals into stream environments would require substantial dilution (237- to 1,429-fold) to reach concentrations equivalent to their 96-h LC50s.

  14. Relation of number and size of fires to fire-season weather indexes in western Washington and western Oregon.

    Treesearch

    Owen P. Cramer

    1959-01-01

    Hard-hitting fire-fighting crews and effective fire prevention held down this year's fire losses despite critical weather." Have you ever read such a statement and wondered how much of the apparently good record was really due to weather conditions?

  15. Fire Safety. Managing School Facilities, Guide 6.

    ERIC Educational Resources Information Center

    Department for Education and Employment, London (England). Architects and Building Branch.

    This booklet discusses how United Kingdom schools can manage fire safety and minimize the risk of fire. The guide examines what legislation school buildings must comply with and covers the major risks. It also describes training and evacuation procedures and provides guidance on fire precautions, alarm systems, fire fighting equipment, and escape…

  16. Presidential Green Chemistry Challenge: 1998 Small Business Award

    EPA Pesticide Factsheets

    Presidential Green Chemistry Challenge 1998 award winner, PYROCOOL Technologies, developed a nontoxic, highly biodegradable fire extinguishing foam to replace ozone-depleting gases and foams that release toxic chemicals.

  17. Multisensor Fire Observations

    NASA Technical Reports Server (NTRS)

    Boquist, C.

    2004-01-01

    This DVD includes animations of multisensor fire observations from the following satellite sources: Landsat, GOES, TOMS, Terra, QuikSCAT, and TRMM. Some of the animations are included in multiple versions of a short video presentation on the DVD which focuses on the Hayman, Rodeo-Chediski, and Biscuit fires during the 2002 North American fire season. In one version of the presentation, MODIS, TRMM, GOES, and QuikSCAT data are incorporated into the animations of these wildfires. These data products provided rain, wind, cloud, and aerosol data on the fires, and monitored the smoke and destruction created by them. Another presentation on the DVD consists of a panel discussion, in which experts from academia, NASA, and the U.S. Forest Service answer questions on the role of NASA in fighting forest fires, the role of the Terra satellite and its instruments, including the Moderate Resolution Imaging Spectroradiometer (MODIS), in fire fighting decision making, and the role of fire in the Earth's climate. The third section of the DVD features several animations of fires over the years 2001-2003, including animations of global and North American fires, and specific fires from 2003 in California, Washington, Montana, and Arizona.

  18. Formulation and characterization of polyimide resilient foams of various densities for aircraft seating applications

    NASA Technical Reports Server (NTRS)

    Gagliani, J.; Lee, R.; Sorathia, U. A. K.

    1981-01-01

    Light weight, heat and fire resistant low smoke generating polyimide foams are developed for aircraft seating applications. The material is upgraded and classified into groups for fabrication of cushions possessing acceptable comfort properties. Refinement and selection of foaming processes using a variety of previously developd foaming techniques and definition of property relationships to arrive at the selection and classfication of polyimide foams into five groups in accordance with predetermined ILD values are emphasized.

  19. Use of Foam to Reduce Gun Blast Noise Levels.

    DTIC Science & Technology

    1981-03-01

    conclusively demonstrated that aqueous foam can effect significant (greater than 10 dB) reductions in gun muzzle blast peak sound pressure level...can yield large reductions in airblast noise level. In these experiments, the explosive charge was engulfed in aqueous foam such as that used in fire...within the foam was closely controlled. Coniguration "C" was also quite similar exc, -" !iat ab .. _ 1 gallon of aqueous foam , contained in a 1-mil

  20. AFFF (Aqueous Film-Forming Foam) Testing of U.S. Air Force Penetrator Nozzle.

    DTIC Science & Technology

    1986-05-01

    Aqueous Film - Forming Foam ( AFFF ), halon, or PKP) flows between this shaft... Film - Forming Foam ( AFFF ). The results showed that increasing the nozzle pressure to 150 psi from the more common fireground pressures of 50 or 100 psi... Forming Foam ( AFFF ) as the fire extinguishing agent. The test plan was designed to determine the optimum nozzle operating pressure considering its effect

  1. Fight Fire with These Safety Strategies.

    ERIC Educational Resources Information Center

    Jackson, Lisa M.

    1998-01-01

    Provides expert guidelines on ways to keep schools and children safe from building fires, such as maintenance of exits for easy egress in emergencies, maintaining fire-protection systems, and utilizing evacuation planning and drilling. Highlights fire-safety ideas as part of school-building and renovation projects. (GR)

  2. 75 FR 3193 - Information Collection; Annual Wildfire Summary Report

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-20

    ... addressed to Tim Melchert, Fire and Aviation Management, National Interagency Fire Center, Forest Service... Forest Service State and Private Forestry Cooperative Fire Program. The program provides supplemental funding for State and local fire fighting agencies. The Forest Service works cooperatively with State and...

  3. Fatigue risk management by volunteer fire-fighters: Use of informal strategies to augment formal policy.

    PubMed

    Dawson, Drew; Mayger, Katherine; Thomas, Matthew J W; Thompson, Kirrilly

    2015-11-01

    An increasing number and intensity of catastrophic fire events in Australia has led to increasing demands on a mainly volunteer fire-fighting workforce. Despite the increasing likelihood of fatigue in the emergency services environment, there is not yet a systematic, unified approach to fatigue management in fire agencies across Australia. Accordingly, the aim of this study was to identify informal strategies used in volunteer fire-fighting and examine how these strategies are transmitted across the workforce. Thirty experienced Australian volunteer fire-fighters were interviewed in August 2010. The study identified informal fatigue-management behaviours at the individual, team and brigade level that have evolved in fire-fighting environments and are regularly implemented. However, their purpose was not explicitly recognized as such. This apparent paradox - that fatigue proofing behaviours exist but that they are not openly understood as such - may well resolve a potential conflict between a culture of indefatigability in the emergency services sector and the frequent need to operate safely while fatigued. However, formal controls require fire-fighters and their organisations to acknowledge and accept their vulnerability. This suggests two important areas in which to improve formal fatigue risk management in the emergency services sector: (1) identifying and formalising tacit or informal fatigue coping strategies as legitimate elements of the fatigue risk management system; and (2) developing culturally appropriate techniques for systematically communicating fatigue levels to self and others. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Preparation, testing, and delivery of low density polyimide foam panels

    NASA Technical Reports Server (NTRS)

    Ball, G. L., III; Post, L. K.; Salyer, I. O.

    1975-01-01

    Plastic foams based on polyimide resins were shown to be stable at relatively high temperatures, and to possess very low flame spread and smoke generation characteristics. A system and process were developed to prepare low-density polyimide foam from a liquid formulation. The system is based on the reaction of micropulverized grade pyromellitic dianhydride with a polymeric diisocyanate. The panels produced were postcured at elevated temperatures to achieve maximum thermal and fire resistance, and incorporation of a fire retardant into the formulation was considered. The effects of a flame retardant (Flameout 5600B1) were investigated, but eliminated in preference to the postcuring approach.

  5. FIRE SERVICE TRAINING, INSTRUCTOR'S MANUAL, BASIC COURSE.

    ERIC Educational Resources Information Center

    BERNDT, WILLIAM M.; AND OTHERS

    INSTRUCTORS CAN USE THIS MANUAL IN CONDUCTING A 34-HOUR FIRE STATION OR TRAINING CENTER EXTENSION PROGRAM TO IMPROVE THE COMPETENCIES AND SKILLS OF LOCAL FIRE PERSONNEL IN THE SPECIALIZED FIELD OF FIRE SERVICE. IT WAS DEVELOPED BY A STATEWIDE COMMITTEE OF FIRE FIGHTING CONSULTANTS AND ADVISORY GROUPS. THE 26 TEACHING GUIDES PROVIDE INSTRUCTIONAL…

  6. Can earthworms survive fire retardants?

    USGS Publications Warehouse

    Beyer, W.N.; Olson, A.

    1996-01-01

    Most common fire retardants are foams or are similar to common agricultural fertilizers, such as ammonium sulfate and ammonium phosphate. Although fire retardants are widely applied to soils, we lack basic information about their toxicities to soil organisms. We measured the toxicity of five fire retardants (Firetrol LCG-R, Firetrol GTS-R, Silv-Ex Foam Concentrate, Phos-chek D-75, and Phos-chek WD-881) to earthworms using the pesticide toxicity test developed for earthworms by the European Economic Community. None was lethal at 1,000 ppm in the soil, which was suggested as a relatively high exposure under normal applications. We concluded that the fire retardants tested are relatively nontoxic to soil organisms compared with other environmental chemicals and that they probably do not reduce earthworm populations when applied under usual firefighting conditions.

  7. Fire hazard considerations for composites in vehicle design

    NASA Technical Reports Server (NTRS)

    Gordon, Rex B.

    1994-01-01

    Military ground vehicles fires are a significant cause of system loss, equipment damage, and crew injury in both combat and non-combat situations. During combat, the ability to successfully fight an internal fire, without losing fighting and mobility capabilities, is often the key to crew survival and mission success. In addition to enemy hits in combat, vehicle fires are initiated by electrical system failures, fuel line leaks, munitions mishaps and improper personnel actions. If not controlled, such fires can spread to other areas of the vehicle, causing extensive damage and the potential for personnel injury and death. The inherent fire safety characteristics (i.e. ignitability, compartments of these vehicles play a major roll in determining rather a newly started fire becomes a fizzle or a catastrophe. This paper addresses a systems approach to assuring optimum vehicle fire safety during the design phase of complex vehicle systems utilizing extensive uses of composites, plastic and related materials. It provides practical means for defining the potential fire hazard risks during a conceptual design phase, and criteria for the selection of composite materials based on its fire safety characteristics.

  8. Mann Gulch fire: A race that couldn't be won

    Treesearch

    Richard C. Rothermel

    1993-01-01

    Describes the final 20 minutes of a smokejumper fire-fighting crew and the fire that overran 16 men as they were attempting to escape. The foreman and two firefighters escaped. Comparison with the behavior of a crew trapped by a fire in 1985 is described.

  9. A quantitative model and the experimental evaluation of the liquid fuel layer for the downward flame spread of XPS foam.

    PubMed

    Luo, Shengfeng; Xie, Qiyuan; Tang, Xinyi; Qiu, Rong; Yang, Yun

    2017-05-05

    The objective of this work is to investigate the distinctive mechanisms of downward flame spread for XPS foam. It was physically considered as a moving down of narrow pool fire instead of downward surface flame spread for normal solids. A method was developed to quantitatively analyze the accumulated liquid fuel based on the experimental measurement of locations of flame tips and burning rates. The results surprisingly showed that about 80% of the generated hot liquid fuel remained in the pool fire during a certain period. Most of the consumed solid XPS foam didn't really burn away but transformed as the liquid fuel in the downward moving pool fire, which might be an important promotion for the fast fire development. The results also indicated that the dripping propensity of the hot liquid fuel depends on the total amount of the hot liquid accumulated in the pool fire. The leading point of the flame front curve might be the breach of the accumulated hot liquid fuel if it is enough for dripping. Finally, it is suggested that horizontal noncombustible barriers for preventing the accumulation and dripping of liquid fuel are helpful for vertical confining of XPS fire. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. 30 CFR 75.1101-5 - Installation of foam generator systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... (b) Foam generator systems shall be equipped with a fire sensor which actuates the system, and each.... (d) Water, power, and chemicals required shall be adequate to maintain water or foam flow for no less than 25 minutes. (e) Water systems shall include strainers with a flush-out connection and a manual...

  11. Fire Protection of Large Air Force Hangars

    DTIC Science & Technology

    1975-10-01

    Aqueous Film - Forming Foam ( AFFF ) in an environment...determining further the effectiveness of 3-percent aqueous film forming foam ( AFFF ); b) determining the effectiveness of AFFF systems at high ceiling...Id SUPPLEMENTARY NOTES 19. KEY WORDS fCont/nu» on reverse side If necessary and Identify by block number) Aqueous Film Forming Foam

  12. Flame Retardants Used in Flexible Polyurethane Foam

    EPA Pesticide Factsheets

    The partnership project on flame retardants in furniture seeks to update the health and environmental profiles of flame-retardant chemicals that meet fire safety standards for upholstered consumer products with polyurethane foam

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matthews, B.; Matthews, R.T.

    Since Drake`s first oil well in 1859, well fires have been frequent and disastrous. Hardly a year has passed in over a century without a well fire somewhere in the world. In the 1920`s the classic method of fire fighting using explosives to starve the fire of oxygen was developed and it has been used extensively ever since. While explosives are still one of the most frequently used methods today, several other methods are used to supplement it where special conditions exist. Tunneling at an angle from a safe distance is used in some cases, especially where the fire ismore » too hot for a close approach on the ground surface. Pumping drilling muds into a well to plug it is another method that has been used successfully for some time. Diverter wells are occasionally used, and sometimes simply pumping enough water on a well fire is sufficient to extinguish it. Of course, prevention is always the best solution. Many advances in blow-out prevention devices have been developed in the last 50 years and the number of fires has been substantially reduced compared to the number of wells drilled. However, very little in new technology has been applied to oil well fire fighting in the 1960s, 1970s, or 1980s. Overall technological progress has accelerated tremendously in this period, of course, but new materials and equipment were not applied to this field for some reason. Saddam Hussein`s environmental holocaust in Kuwait changed that by causing many people throughout the world to focus their creative energy on more efficient oil well fire fighting methods.« less

  14. LSD 36 Well Deck Fire Protection

    DTIC Science & Technology

    1991-05-30

    below, which are loaded with personnel, vehicles and supplies. Normally, an Aqueous Film Forming Foam ( AFFF ) sprinkler system would be recommended for...the foam to the center area and allow the AFFF film to spread out from there; or, some combination of the two approaches. Results Phase I Tests A...landing craft and vehicles stored in the well deck below. Based on these tests, the optimum fire protection system would involve an Aqueous Film

  15. 46 CFR 76.17-25 - Additional protection required.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... PROTECTION EQUIPMENT Foam Extinguishing Systems, Details § 76.17-25 Additional protection required. (a) In order that any residual fires above the floor plates may be extinguished when a foam system is installed...

  16. 46 CFR 76.17-25 - Additional protection required.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... PROTECTION EQUIPMENT Foam Extinguishing Systems, Details § 76.17-25 Additional protection required. (a) In order that any residual fires above the floor plates may be extinguished when a foam system is installed...

  17. Fire resistant aircraft seat program

    NASA Technical Reports Server (NTRS)

    Fewell, L. A.

    1979-01-01

    Foams, textiles, and thermoformable plastics were tested to determine which materials were fire retardant, and safe for aircraft passenger seats. Seat components investigated were the decorative fabric cover, slip covers, fire blocking layer, cushion reinforcement, and the cushioning layer.

  18. 49 CFR 176.69 - General stowage requirements for hazardous materials.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... equipped with a fixed fire extinguishing and fire detection system, the freight containers or barges need... by paragraph (a) of this section if fire fighting equipment capable of reaching and piercing the..., their removal from a potentially dangerous situation, and the removal of packages in case of fire. (b...

  19. Thermally insulating and fire-retardant lightweight anisotropic foams based on nanocellulose and graphene oxide.

    PubMed

    Wicklein, Bernd; Kocjan, Andraž; Salazar-Alvarez, German; Carosio, Federico; Camino, Giovanni; Antonietti, Markus; Bergström, Lennart

    2015-03-01

    High-performance thermally insulating materials from renewable resources are needed to improve the energy efficiency of buildings. Traditional fossil-fuel-derived insulation materials such as expanded polystyrene and polyurethane have thermal conductivities that are too high for retrofitting or for building new, surface-efficient passive houses. Tailored materials such as aerogels and vacuum insulating panels are fragile and susceptible to perforation. Here, we show that freeze-casting suspensions of cellulose nanofibres, graphene oxide and sepiolite nanorods produces super-insulating, fire-retardant and strong anisotropic foams that perform better than traditional polymer-based insulating materials. The foams are ultralight, show excellent combustion resistance and exhibit a thermal conductivity of 15 mW m(-1) K(-1), which is about half that of expanded polystyrene. At 30 °C and 85% relative humidity, the foams retained more than half of their initial strength. Our results show that nanoscale engineering is a promising strategy for producing foams with excellent properties using cellulose and other renewable nanosized fibrous materials.

  20. Modeling Heat Transfer and Pressurization of Polymeric Methylene Diisocyanate (PMDI) Polyurethane Foam in a Sealed Container.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scott, Sarah Nicole

    Polymer foam encapsulants provide mechanical, electrical, and thermal isolation in engineered systems. It can be advantageous to surround objects of interest, such as electronics, with foams in a hermetically sealed container to protect the electronics from hostile en vironments, such as a crash that produces a fire. However, i n fire environments, gas pressure from thermal decomposition of foams can cause mechanical failure of the sealed system . In this work, a detailed study of thermally decomposing polymeric methylene diisocyanate (PMDI) - polyether - polyol based polyurethane foam in a sealed container is presented . Both experimental and computational workmore » is discussed. Three models of increasing physics fidelity are presented: No Flow, Porous Media, and Porous Media with VLE. Each model us described in detail, compared to experiment , and uncertainty quantification is performed. While the Porous Media with VLE model matches has the best agreement with experiment, it also requires the most computational resources.« less

  1. A WSN-based tool for urban and industrial fire-fighting.

    PubMed

    De San Bernabe Clemente, Alberto; Martínez-de Dios, José Ramiro; Ollero Baturone, Aníbal

    2012-11-06

    This paper describes a WSN tool to increase safety in urban and industrial fire-fighting activities. Unlike most approaches, we assume that there is no preexisting WSN in the building, which involves interesting advantages but imposes some constraints. The system integrates the following functionalities: fire monitoring, firefighter monitoring and dynamic escape path guiding. It also includes a robust localization method that employs RSSI-range models dynamically trained to cope with the peculiarities of the environment. The training and application stages of the method are applied simultaneously, resulting in significant adaptability. Besides simulations and laboratory tests, a prototype of the proposed system has been validated in close-to-operational conditions.

  2. The Effect of Computer-Based Simulation Training on Fire Ground Incident Commander Decision Making

    ERIC Educational Resources Information Center

    Hall, Kurt A.

    2010-01-01

    Since the establishment of the first volunteer fire brigades in the United States, firefighters have lost their lives in fire fighting operations at emergency incidents and live-fire training activities. While there are various reasons for these firefighter deaths and injuries, the United States Fire Administration (2002) reported that many of…

  3. Novel Elastomeric Closed Cell Foam - Nonwoven Fabric Composite Material (Phase III)

    DTIC Science & Technology

    2008-10-01

    increasing the polymer content of the foam. From laboratory studies, processing was found to improve by using different types of NBR rubber . The AF07 B...Foam Optimization (Task 1) Prior development of fire retarded closed cell foam yielded attractive candidates for scale-up. Nitrile-butadiene rubber ... NBR ) and polyvinyl chloride (PVC) blends provided the most cost effective solutions. Two types of formulas were chosen for optimization. The first

  4. Three-phase foam analysis and development of a lab-scale foaming capacity and stability test for swine manure

    USDA-ARS?s Scientific Manuscript database

    Foam accumulation on the manure slurry at deep pit swine facilities has been linked to flash fire incidents, making it a serious safety concern for pork producers. In order to investigate this phenomenon, samples of swine manure were collected from over 50 swine production facilities in Iowa with va...

  5. 40 CFR 63.8800 - What performance tests and other procedures must I use to demonstrate compliance with the...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Emission Standards for Hazardous Air Pollutants: Flexible Polyurethane Foam Fabrication Operations Testing... paragraphs (e)(1) through (3) of this section. (1) If you use chlorinated fire retardant foams, determine the... retardant foams, determine the percent reduction of HCN to represent HAP emissions from the source. (2...

  6. 40 CFR 63.8800 - What performance tests and other procedures must I use to demonstrate compliance with the...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Emission Standards for Hazardous Air Pollutants: Flexible Polyurethane Foam Fabrication Operations Testing... paragraphs (e)(1) through (3) of this section. (1) If you use chlorinated fire retardant foams, determine the... retardant foams, determine the percent reduction of HCN to represent HAP emissions from the source. (2...

  7. 40 CFR 63.8800 - What performance tests and other procedures must I use to demonstrate compliance with the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Emission Standards for Hazardous Air Pollutants: Flexible Polyurethane Foam Fabrication Operations Testing... paragraphs (e)(1) through (3) of this section. (1) If you use chlorinated fire retardant foams, determine the... retardant foams, determine the percent reduction of HCN to represent HAP emissions from the source. (2...

  8. 40 CFR 63.8800 - What performance tests and other procedures must I use to demonstrate compliance with the...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Emission Standards for Hazardous Air Pollutants: Flexible Polyurethane Foam Fabrication Operations Testing... paragraphs (e)(1) through (3) of this section. (1) If you use chlorinated fire retardant foams, determine the... retardant foams, determine the percent reduction of HCN to represent HAP emissions from the source. (2...

  9. 40 CFR 63.8800 - What performance tests and other procedures must I use to demonstrate compliance with the...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Emission Standards for Hazardous Air Pollutants: Flexible Polyurethane Foam Fabrication Operations Testing... paragraphs (e)(1) through (3) of this section. (1) If you use chlorinated fire retardant foams, determine the... retardant foams, determine the percent reduction of HCN to represent HAP emissions from the source. (2...

  10. Decision Document for the Storm Water Outfalls/Industrial Wastewater Treatment Plant, Pesticide Rinse Area, Old Fire Fighting Training Pit, Illicit PCB Dump Site, and the Battery Acid Pit Fort Lewis, Washington

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cantrell, Kirk J; Liikala, Terry L; Strenge, Dennis L

    PNNL conducted independent site evaluations for four sites at Fort Lewis, Washington, to determine their suitability for closure on behalf of the installation. These sites were recommended for ''No Further Action'' by previous investigators and included the Storm Water Outfalls/Industrial Waste Water Treatment Plant (IWTP), the Pesticide Rinse Area, the Old Fire Fighting Training Pit, and the Illicit PCB Dump Site.

  11. Decision Document for the Storm Water Outfalls/Industrial Wastewater Treatment Plant, Pesticide Rinse Area, Old Fire Fighting Training Pit, Illicit PCB Dump Site, and the Battery Acid Pit Fort Lewis, Washington

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cantrell, Kirk J.; Liikala, Terry L.; Strenge, Dennis L.

    PNNL conducted independent site evaluations for four sites at Fort Lewis, Washington, to determine their suitability for closure on behalf of the installation. These sites were recommended for "No Further Action" by previous invesitgators and included the Storm Water Outfalls/Industrial Waste Water Treatment Plant (IWTP), the Pesticide Rinse Area, the Old Fire Fighting Training Pit, and the Illicit PCB Dump Site.

  12. Individual Combatant’s Weapons Firing Algorithm Phase 1

    DTIC Science & Technology

    2010-06-01

    Z as in zebra...Drilis? 2 - 5 years ago More than 6 years ago 7. ~HOW~ z ~~:::: fire fights have you been In1 3-9 10 or more 8. Of those fights, what percentage were...34, ~ ’~-<’" ;-~/Nr,. ~ ~ "~t’ "X\\’ikJ ~ ,.’ \\1" ’: ’\\ Z ;J;l~~’i/’r.i\\ I " ,.. ..... ’-.-1 . , .. ,~ . \\\\ 1 ;C~"~~~~,~,, ~’",~"",~, ........... ~ f·

  13. Fire propagation performance of intumescent fire protective coatings using eggshells as a novel biofiller.

    PubMed

    Yew, M C; Ramli Sulong, N H; Yew, M K; Amalina, M A; Johan, M R

    2014-01-01

    This paper aims to synthesize and characterize an effective intumescent fire protective coating that incorporates eggshell powder as a novel biofiller. The performances of thermal stability, char formation, fire propagation, water resistance, and adhesion strength of coatings have been evaluated. A few intumescent flame-retardant coatings based on these three ecofriendly fire retardant additives ammonium polyphosphate phase II, pentaerythritol and melamine mixed together with flame-retardant fillers, and acrylic binder have been prepared and designed for steel. The fire performance of the coatings has conducted employing BS 476: Part 6-Fire propagation test. The foam structures of the intumescent coatings have been observed using field emission scanning electron microscopy. On exposure, the coated specimens' B, C, and D had been certified to be Class 0 due to the fact that their fire propagation indexes were less than 12. Incorporation of ecofriendly eggshell, biofiller into formulation D led to excellent performance in fire stopping (index value, (I) = 4.3) and antioxidation of intumescent coating. The coating is also found to be quite effective in water repellency, uniform foam structure, and adhesion strength.

  14. Fire Propagation Performance of Intumescent Fire Protective Coatings Using Eggshells as a Novel Biofiller

    PubMed Central

    Yew, M. C.; Ramli Sulong, N. H.; Yew, M. K.; Amalina, M. A.; Johan, M. R.

    2014-01-01

    This paper aims to synthesize and characterize an effective intumescent fire protective coating that incorporates eggshell powder as a novel biofiller. The performances of thermal stability, char formation, fire propagation, water resistance, and adhesion strength of coatings have been evaluated. A few intumescent flame-retardant coatings based on these three ecofriendly fire retardant additives ammonium polyphosphate phase II, pentaerythritol and melamine mixed together with flame-retardant fillers, and acrylic binder have been prepared and designed for steel. The fire performance of the coatings has conducted employing BS 476: Part 6-Fire propagation test. The foam structures of the intumescent coatings have been observed using field emission scanning electron microscopy. On exposure, the coated specimens' B, C, and D had been certified to be Class 0 due to the fact that their fire propagation indexes were less than 12. Incorporation of ecofriendly eggshell, biofiller into formulation D led to excellent performance in fire stopping (index value, (I) = 4.3) and antioxidation of intumescent coating. The coating is also found to be quite effective in water repellency, uniform foam structure, and adhesion strength. PMID:25136687

  15. Organic pollutant loading and biodegradability of firefighting foam

    NASA Astrophysics Data System (ADS)

    Zhang, Xian-Zhong; Bao, Zhi-ming; Hu, Cheng; Li-Shuai, Jing; Chen, Yang

    2017-11-01

    Firefighting foam has been widely used as the high-performance extinguishing agent in extinguishing the liquid poor fire. It was concerned for its environmental impacts due to its massive usage. In this study, the organic loading level and the biodegradability of 18 firefighting foams commonly used in China were evaluated and compared. The COD and TOC of firefighting foam concentrates are extremely high. Furthermore, those of foam solutions are also much higher than regular wastewater. The COD/TOC ratio of synthetic foams are higher than protein foams. The 28-day biodegradation rates of 18 firefighting foams are all over 60%, indicating that they are all ready biodegradable. Protein foams (P, FP and FFFP) have the higher organic loading and lower 28-day biodegradation rates compared to the synthetic foams (Class A foam, AFFF and S). The short and long-term impact of protein foams on the environment are larger than synthetic foams.

  16. NASA helicopter helps fight fire at KSC

    NASA Technical Reports Server (NTRS)

    2000-01-01

    A NASA helicopter drops water from a special '''bucket''' onto a small fire on Kennedy Space Center grounds. The site is between Kennedy Parkway North and the Indian River. The fire is one of many throughout Central Florida, which is suffering from drought.

  17. STS-47 crew during fire fighting exercises at JSC's Fire Training Pit

    NASA Technical Reports Server (NTRS)

    1992-01-01

    STS-47 Endeavour, Orbiter Vehicle (OV) 105, crewmembers line up along water hoses to extinguish a blaze in JSC's Fire Training Pit during fire fighting exercises. Manning the hose in the foreground are Payload Specialist Mamoru Mohri, holding the hose nozzle, backup Payload Specialist Takao Doi, Mission Specialist (MS) Jerome Apt, and Commander Robert L. Gibson, at rear. Lined up on the second hose are Pilot Curtis L. Brown, Jr, holding the hose nozzle, followed by MS N. Jan Davis, MS and Payload Commander (PLC) Mark C. Lee, and backup Payload Specialist Stan Koszelak. A veteran firefighter monitors the effort from a position between the two hoses. In the background, backup Payload Specialist Chiaki Naito-Mukai, donning gloves, and MS Mae C. Jemison look on. The Fire Training Pit is located across from the Gilruth Center Bldg 207. Mohri, Doi, and Mukai all represent Japan's National Space Development Agency (NASDA).

  18. 33 CFR 127.1307 - Emergency Manual.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ....1505(a)(2). (b) The employee-emergency plan and fire-prevention plan required by OSHA in 29 CFR 1910.38... procedures for fighting a fire involving the LHG or its vapors; (2) A description of the emergency shutdown..., place, and use of the fire equipment required by § 127.1501(a) and of the portable fire extinguishers...

  19. 33 CFR 127.1307 - Emergency Manual.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ....1505(a)(2). (b) The employee-emergency plan and fire-prevention plan required by OSHA in 29 CFR 1910.38... procedures for fighting a fire involving the LHG or its vapors; (2) A description of the emergency shutdown..., place, and use of the fire equipment required by § 127.1501(a) and of the portable fire extinguishers...

  20. 33 CFR 127.1307 - Emergency Manual.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ....1505(a)(2). (b) The employee-emergency plan and fire-prevention plan required by OSHA in 29 CFR 1910.38... procedures for fighting a fire involving the LHG or its vapors; (2) A description of the emergency shutdown..., place, and use of the fire equipment required by § 127.1501(a) and of the portable fire extinguishers...

  1. 33 CFR 127.1307 - Emergency Manual.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ....1505(a)(2). (b) The employee-emergency plan and fire-prevention plan required by OSHA in 29 CFR 1910.38... procedures for fighting a fire involving the LHG or its vapors; (2) A description of the emergency shutdown..., place, and use of the fire equipment required by § 127.1501(a) and of the portable fire extinguishers...

  2. 75 FR 35437 - Notice of Request for Extension of a Currently Approved Information Collection

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-22

    ... from construction of a fire station with fire fighting and rescue equipment to financing a 911 emergency system. These facilities are designed to provide fire protection and emergency rescue services to... for a currently approved information collection in support of the program for Fire and Rescue Loans...

  3. 46 CFR 34.17-25 - Additional protection required-T/ALL.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Fixed Foam Extinguishing Systems, Details § 34.17-25 Additional protection required—T/ALL. (a) In order that any residual fires above the floor plates may be extinguished when a foam system is installed for...

  4. 46 CFR 34.17-25 - Additional protection required-T/ALL.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Fixed Foam Extinguishing Systems, Details § 34.17-25 Additional protection required—T/ALL. (a) In order that any residual fires above the floor plates may be extinguished when a foam system is installed for...

  5. Non-flammable polyimide materials for aircraft and spacecraft applications

    NASA Technical Reports Server (NTRS)

    Gagliani, J.; Supkis, D. E.

    1979-01-01

    Recent developments in polyimide chemistry show promise for producing materials with very low flammability and a wide range of mechanical properties. Polyimide foams can be synthesized to provide fire safety without detectable formation of smoke or toxic byproducts below 204 C (400 F), thus avoiding an environment which is lethal to human habitation. This work has been and is currently being performed under development programs, the objective of which is to provide cost effective processes for producing thermally stable, polyimide flexible resilient foams, thermal-acoustical insulating materials, rigid low density foam panels, and high strength foam structures. The chemical and physical properties demonstrated by these materials represent a technological advancement in the art of thermally stable polyimide polymers which are expected to insure fire protection of structures and components used in air transportation and space exploration. Data compiled to date on thermal, physical and functional properties of these materials are presented.

  6. An Educational Program Dealing with Fire Safety. Curriculum and Resource Guide.

    ERIC Educational Resources Information Center

    Rhode Island State Dept. of Education, Providence.

    A series of activities for fire safety education in grades K-12 is presented. The document is organized into three parts: grades K-3; 4-6; and 7-12. Each activity is preceded by general and specific concepts to be stressed. Concepts for grades K-3 stress usefulness and types of fire, fire drills, the fire fighting profession, and the…

  7. Szendro - type Integrated Vegetation Fire Management--Wildfire Management Program from Hungary

    Treesearch

    Ágoston Restás

    2006-01-01

    Szendrő Fire Department is located in the northeastern part of Hungary. The main task is to fight against wildfire and mitigate the impact of fire at the Aggtelek National Park -- which belongs to the UNESCO World Heritage list. Because of greater effectiveness, in 2004 the Fire Department started a project named Integrated Vegetation Fire Management (IVFM)....

  8. Fighting Fire with Fire.

    ERIC Educational Resources Information Center

    Spoor, Dana L.

    1996-01-01

    School districts are integrating security and life-safety systems into school buildings to protect students and property. This proactive approach includes sprinkler systems, fire alarms, and security systems that monitor door movement. Some school districts that are incorporating the latest life-safety technology are in Missouri, Ohio, California,…

  9. 33 CFR 145.05 - Classification of fire extinguishers.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Classification of fire... SECURITY (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES FIRE-FIGHTING EQUIPMENT § 145.05 Classification of....05(c)—Portable and Semiportable Extinguishers Classification Type Size Soda-acid and water, gallons...

  10. 78 FR 40089 - Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-03

    .... The FS works cooperatively with State and local fire fighting agencies to support their fire... fires and acres burned on State and private land by cause, such as lightning, campfires, smoking, debris burning, arson, equipment, railroads, children and miscellaneous activities. Information will be shared...

  11. Future Role of Fire Service in Homeland Security

    DTIC Science & Technology

    2008-09-01

    to fight terrorism (Office of the President, 2007). In his letter to Americans in which he introduced the NSHS, President Bush explained that...structures struggling to fight non-state terrorists operating without clearly defined leadership. Furthermore, according to James R. Locker III...learned from World War II and designed to fight the Cold War. Current exposure to terrorism and terrorist cells is vastly different 16 from

  12. Foam Core Particleboards with Intumescent FRT Veneer: Cone Calorimeter Testing With Varying Adhesives, Surface Layer Thicknesses, and Processing Conditions

    Treesearch

    Mark A. Dietenberger; Johannes Welling; Ali Shalbafan

    2014-01-01

    Intumescent FRT Veneers adhered to the surface of foam core particleboard to provide adequate fire protection were evaluated by means of cone calorimeter tests (ASTM E1354). The foam core particleboards were prepared with variations in surface layer treatment, adhesives, surface layer thicknesses, and processing conditions. Ignitability, heat release rate profile, peak...

  13. Reticulite, Scoria and Lava: Foam Formation in Hawaiian Fire Fountain Eruptions

    NASA Astrophysics Data System (ADS)

    Rust, A. C.; Cashman, K. V.

    2006-12-01

    Hawaiian fire fountain eruptions can generate three types of foams: 1) scoria pyroclasts characterized by spherical bubbles and typical vesicularities of 70-85%, 2) reticulite pyroclasts consisting of a polygonal network of trigonal glass struts and vesicularities of 95-99% and 3) lava flows with bubble contents as high as 70-80%. We use bubble textures to explore the origins of these three distinct foams. With these data and the observation that all three foam types can erupt simultaneously, we discuss the dynamics of Hawaiian eruptions. Our main focus is reticulite, which is a minor but ubiquitous product of relatively high Hawaiian fountains. Compared to scoria, reticulite is more vesicular and has a larger mean bubble size and a much more uniform bubble size distribution. It was previously suggested that reticulite results from further expansion of hot scoria foam. However, to form reticulite from scoria requires not only that gas expand faster than it can percolate through bubble networks in scoria, but also requires processes such as Ostwald ripening that will reduce the range of bubble sizes. Such processes commonly occur in the formation of polygonal soap foams for instance. However, we suggest that a better analogue for reticulite formation is popcorn. In particular we propose that reticulite did not evolve from scoria but from magma that experienced (1) near-instantaneous bubble nucleation followed by (2) rapid and uniform expansion to generate (3) a polyhedral 'dry' foam that then (4) experienced near-instantaneous film rupture and quenching throughout the foam. In contrast, it seems that there are other parts of the system where bubble nucleation is not instantaneous and yields a broader size distribution of bubbles that expand more slowly, maintain spherical shapes, and become permeable through coalescence of small melt films between spherical bubble walls. We suggest that reticulite only forms in relatively high fire fountains, not because of longer time for expansion but because of higher ascent rates in these eruptions.

  14. Partial Analysis of Insta-Foam

    NASA Technical Reports Server (NTRS)

    Chou, L. W.

    1983-01-01

    Insta-Foam, used as a thermal insulator for the non-critical area of the external tank during the prelaunch phase to minimize icing, is a two-component system. Component A has polyisocyanates, blowing agents, and stabilizers; Component B has the polyols, catalysts, blowing agents, stabilizers and fire retardant. The blowing agents are Freon 11 and Freon 12, the stabilizers are silicone surfactants, the catalysts are tertiary amines, and the fire retardant is tri-(beta-chloro-isopropyl) phosphate (PCF). High performance liquid chromatography (HPLC) was quantitatively identified polyols and PFC.

  15. A WSN-Based Tool for Urban and Industrial Fire-Fighting

    PubMed Central

    De San Bernabe Clemente, Alberto; Dios, José Ramiro Martínez-de; Baturone, Aníbal Ollero

    2012-01-01

    This paper describes a WSN tool to increase safety in urban and industrial fire-fighting activities. Unlike most approaches, we assume that there is no preexisting WSN in the building, which involves interesting advantages but imposes some constraints. The system integrates the following functionalities: fire monitoring, firefighter monitoring and dynamic escape path guiding. It also includes a robust localization method that employs RSSI-range models dynamically trained to cope with the peculiarities of the environment. The training and application stages of the method are applied simultaneously, resulting in significant adaptability. Besides simulations and laboratory tests, a prototype of the proposed system has been validated in close-to-operational conditions. PMID:23202198

  16. A portable W-band radar system for enhancement of infrared vision in fire fighting operations

    NASA Astrophysics Data System (ADS)

    Klenner, Mathias; Zech, Christian; Hülsmann, Axel; Kühn, Jutta; Schlechtweg, Michael; Hahmann, Konstantin; Kleiner, Bernhard; Ulrich, Michael; Ambacher, Oliver

    2016-10-01

    In this paper, we present a millimeter wave radar system which will enhance the performance of infrared cameras used for fire-fighting applications. The radar module is compact and lightweight such that the system can be combined with inertial sensors and integrated in a hand-held infrared camera. This allows for precise distance measurements in harsh environmental conditions, such as tunnel or industrial fires, where optical sensors are unreliable or fail. We discuss the design of the RF front-end, the antenna and a quasi-optical lens for beam shaping as well as signal processing and demonstrate the performance of the system by in situ measurements in a smoke filled environment.

  17. 46 CFR 28.825 - Excess fire detection and protection equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...” “CARBON DIOXIDE FIRE SYSTEM” or “FOAM FIRE SYSTEM”, as the case may be; (v) Instructions for the operation... be locked, a key to the space or enclosure shall be in a break-glass-type box conspicuously located...

  18. Low Level Impacts on Fire Evolution in the Mack Lake and Other Severe Wildfires

    Treesearch

    Joseph J. Charney; Xindi Bian; Brian E. Potter; Warren E. Heilman

    2003-01-01

    The 2000 fire season brought to the forefront the issue of severe wildland fires in the United States. To address the need for new research and for the development of predictive tools for managing wildland fires, Congress allocated funding under the National Fire Plan (NFP) to better equip government agencies to fight and study forest fires. As part of the NFP research...

  19. One-pot, bioinspired coatings to reduce the flammability of flexible polyurethane foams.

    PubMed

    Davis, Rick; Li, Yu-Chin; Gervasio, Michelle; Luu, Jason; Kim, Yeon Seok

    2015-03-25

    In this manuscript, natural materials were combined into a single "pot" to produce flexible, highly fire resistant, and bioinspired coatings on flexible polyurethane foam (PUF). In one step, PUF was coated with a fire protective layer constructed of a polysaccharide binder (starch or agar), a boron fire retardant (boric acid or derivative), and a dirt char former (montmorillonite clay). Nearly all coatings produced a 63% reduction in a critical flammability value, the peak heat release rate (PHRR). One formulation produced a 75% reduction in PHRR. This technology was validated in full-scale furniture fire tests, where a 75% reduction in PHRR was measured. At these PHRR values, this technology could reduce the fire threat of furniture from significant fire damage in and beyond the room of fire origin to being contained to the burning furniture. This flammability reduction was caused by three mechanisms-the gas-phase and condensed-phase processes of the boron fire retardant and the condensed-phase process of the clay. We describe the one-pot coating process and the impact of the coating composition on flammability.

  20. An integer programming model to optimize resource allocation for wildfire containment.

    Treesearch

    Geoffrey H. Donovan; Douglas B. Rideout

    2003-01-01

    Determining the specific mix of fire-fighting resources for a given fire is a necessary condition for identifying the minimum of the Cost Plus Net Value Change (C+NVC) function. Current wildland fire management models may not reliably do so. The problem of identifying the most efficient wildland fire organization is characterized mathematically using integer-...

  1. Polyimide foam for the thermal insulation and fire protection

    NASA Technical Reports Server (NTRS)

    Rosser, R. W. (Inventor)

    1973-01-01

    The preparation of chemically resistant and flame retardant foams from polyfunctional aromatic carboxylic acid derivatives and organic polyisocyanates is outlined. It was found that polyimide foams of reproducible density above 1 lb./ft. and below 6 lbs./cu ft. can be obtained by employing in the reaction of least 2% by weight of siloxane-glycol copolymer as a surfactant which acts as a specific density control agent. Polyimide foams into which reinforcing fibers such as silicon dioxide and carbon fibers may be incorporated were also produced.

  2. Fabrics for fire resistant passenger seats in aircraft

    NASA Technical Reports Server (NTRS)

    Tesoro, G. C.

    1978-01-01

    The essential elements of the problem and of approaches to improved fire resistance in aircraft seats are reviewed. The performance requirements and availability of materials, delay in the ignition of upholstery fabric by a small source are considered a realistic objective. Results of experimental studies on the thermal response of fabrics and fabric/foam combinations suggest significant conclusions regarding: (1) the ignition behavior of a commercial 90/10 wool/nylon upholstery fabric relative to fabrics made from thermally stable polymers; (2) the role of the foam backing; (3) the behavior of seams. These results, coupled with data from other sources, also confirm the importance of materials' interactions in multicomponent assemblies, and the need for system testing prior to materials' selection. The use of an interlinear or thermal barrier between upholstery fabric and foam is a promising and viable approach to improved fire resistance of the seat assembly, but experimental evaluation of specific combinations of materials or systems is an essential part of the selection process.

  3. 33 CFR 145.05 - Classification of fire extinguishers.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... SECURITY (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES FIRE-FIGHTING EQUIPMENT § 145.05 Classification of... means so that all portions of the space concerned may be covered. Examples of size graduations for some...

  4. 33 CFR 145.05 - Classification of fire extinguishers.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... SECURITY (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES FIRE-FIGHTING EQUIPMENT § 145.05 Classification of... means so that all portions of the space concerned may be covered. Examples of size graduations for some...

  5. 33 CFR 145.05 - Classification of fire extinguishers.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... SECURITY (CONTINUED) OUTER CONTINENTAL SHELF ACTIVITIES FIRE-FIGHTING EQUIPMENT § 145.05 Classification of... means so that all portions of the space concerned may be covered. Examples of size graduations for some...

  6. Defense.gov Special Report: California Wildfires

    Science.gov Websites

    Fight California Wildfires U.S. Marines and aircraft with 3rd Marine Aircraft Wing and fire crews on Wildfires CDC Emergency Preparedness - Wildfires Current California Fire Information (CA.gov) Official Camp

  7. 33 CFR 401.94 - Keeping copies of regulations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... duplicated set of the Ship's Fire Control Plans shall be permanently stored in a prominently marked weather-tight enclosure outside the deckhouse for the assistance of shore-side fire-fighting personnel. [70 FR...

  8. 33 CFR 401.94 - Keeping copies of regulations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... duplicated set of the Ship's Fire Control Plans shall be permanently stored in a prominently marked weather-tight enclosure outside the deckhouse for the assistance of shore-side fire-fighting personnel. [70 FR...

  9. 46 CFR 95.17-90 - Installations contracted for prior to November 19, 1952.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Foam Extinguishing Systems, Details § 95.17-90 Installations... exception of § 95.17-5(a)(2), insofar as is reasonable and practicable. A 6-inch blanket of foam in 5...

  10. 46 CFR 76.17-90 - Installations contracted for prior to November 19, 1952.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... VESSELS FIRE PROTECTION EQUIPMENT Foam Extinguishing Systems, Details § 76.17-90 Installations contracted... of § 76.17-5(a)(2), insofar as is reasonable and practicable. A 6-inch blanket of foam in 5 minutes...

  11. 46 CFR 76.17-90 - Installations contracted for prior to November 19, 1952.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... VESSELS FIRE PROTECTION EQUIPMENT Foam Extinguishing Systems, Details § 76.17-90 Installations contracted... of § 76.17-5(a)(2), insofar as is reasonable and practicable. A 6-inch blanket of foam in 5 minutes...

  12. 46 CFR 95.17-90 - Installations contracted for prior to November 19, 1952.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Foam Extinguishing Systems, Details § 95.17-90 Installations... exception of § 95.17-5(a)(2), insofar as is reasonable and practicable. A 6-inch blanket of foam in 5...

  13. 25 CFR 163.28 - Fire management measures.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... wildfire protection needs and extinguish forest or range fires on Indian land. No expenses for fighting a... 25 Indians 1 2010-04-01 2010-04-01 false Fire management measures. 163.28 Section 163.28 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR LAND AND WATER GENERAL FORESTRY REGULATIONS Forest...

  14. U.S. Coast Guard cutter personnel on Sweetbriar train their fire ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    U.S. Coast Guard cutter personnel on Sweetbriar train their fire hoses on a burning pleasure boat in an Alaskan harbor. A U.S. Coast Guard rigid-hull inflatable helps with the fire-fighting effort - U.S. Coast Guard Cutter SWEETBRIER, Cordova, Valdez-Cordova Census Area, AK

  15. 24 CFR 3280.207 - Requirements for foam plastic thermal insulating materials.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... include intensity of cavity fire (temperature-time) and post-test damage. (iii) Post-test damage... Technology Research Institute (IIT) Report, “Development of Mobile Home Fire Test Methods to Judge the Fire... Project J-6461, 1979” or other full-scale fire tests accepted by HUD, and it is installed in a manner...

  16. 24 CFR 3280.207 - Requirements for foam plastic thermal insulating materials.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... include intensity of cavity fire (temperature-time) and post-test damage. (iii) Post-test damage... Technology Research Institute (IIT) Report, “Development of Mobile Home Fire Test Methods to Judge the Fire... Project J-6461, 1979” or other full-scale fire tests accepted by HUD, and it is installed in a manner...

  17. 24 CFR 3280.207 - Requirements for foam plastic thermal insulating materials.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... include intensity of cavity fire (temperature-time) and post-test damage. (iii) Post-test damage... Technology Research Institute (IIT) Report, “Development of Mobile Home Fire Test Methods to Judge the Fire... Project J-6461, 1979” or other full-scale fire tests accepted by HUD, and it is installed in a manner...

  18. 24 CFR 3280.207 - Requirements for foam plastic thermal insulating materials.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... include intensity of cavity fire (temperature-time) and post-test damage. (iii) Post-test damage... Technology Research Institute (IIT) Report, “Development of Mobile Home Fire Test Methods to Judge the Fire... Project J-6461, 1979” or other full-scale fire tests accepted by HUD, and it is installed in a manner...

  19. 24 CFR 3280.207 - Requirements for foam plastic thermal insulating materials.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... include intensity of cavity fire (temperature-time) and post-test damage. (iii) Post-test damage... Technology Research Institute (IIT) Report, “Development of Mobile Home Fire Test Methods to Judge the Fire... Project J-6461, 1979” or other full-scale fire tests accepted by HUD, and it is installed in a manner...

  20. Spacecraft Fire Safety: A Human Space Flight Program Perspective

    NASA Technical Reports Server (NTRS)

    Pedley, Michael D.

    2003-01-01

    This paper presents viewgraphs on the International Space Station's fire safety program from a human space flight perspective. The topics include: 1) Typical Manned Spacecraft Materials; 2) Typical Flammable Hardware Protection; 3) Materials Flammability; 4) Fire Retardants; 5) Nonflammable Foam Cushion Material; 6) Electrical Wire and Cable; 7) Russian Solid-Fuel Oxygen Generator (SFOG); 8) GOX Ignition Mechanisms; 9) Fire Detection; and 10) Fire Suppression.

  1. DefenseLink Feature: Military Helps Fight California Wildfires

    Science.gov Websites

    planes dropping fire retardant on wildfires in southern California face hazards and challenges unique to ' * Sailors Help Victims in Need * Bush Pledges Military Will Continue to Provide Fire Aid | Video

  2. Water Supply Systems For Aircraft Fire And Rescue Protection

    DOT National Transportation Integrated Search

    1995-01-01

    This Advisory Circular (AC) provides guidance for the selection : of a water source and standards for the design of a distribution system to : support aircraft rescue and fire fighting (ARFF) service operations on : airports.

  3. The applicability of different waste materials for the production of lightweight aggregates.

    PubMed

    Ducman, V; Mirtic, B

    2009-08-01

    The applicability of different waste materials for the production of lightweight aggregates has been studied. The following waste materials were investigated: silica sludge, superfluous clay in the quarry, waste glass, and residue from the polishing process of different types of stone. SiC and MnO(2) were selected as foaming agents. Feldspar containing minerals and scrap glass were added in order to lower the softening point of the waste materials. The granules were prepared by mixing together finely ground waste with one or both of the selected foaming agents. The granules were then fired at different temperatures above the softening point of the glassy phase within the temperature range from 1150 to 1220 degrees C, where the foaming agent degasses, and the resulting gasses remain trapped in the glassy structure. The foaming process was observed by hot-stage microscopy. The properties of the so-obtained granules, such as their apparent density and compressive strength, were determined, and their microstructures were evaluating using SEM and polarizing microscopy. With the addition to clay of polishing residue from granite-like rocks, after firing at 1220 degrees C homogeneously porous granules with a density down to 0.42 g/cm(3) were obtained, whereas with the addition to waste silica sludge of polishing residue from granite-like rocks and waste glass with a foaming agent, after firing at 1220 degrees C densities from 0.57 to 0.82 g/cm(3) were obtained.

  4. Desonide Topical

    MedlinePlus

    ... may increase side effects.Desonide foam may catch fire. Stay away from open fire, flames, and do not smoke while you are ... supplements, and herbal products you are taking or plan to take. Be sure to mention the following: ...

  5. Airborne forest fire research

    NASA Technical Reports Server (NTRS)

    Mattingly, G. S.

    1974-01-01

    The research relating to airborne fire fighting systems is reviewed to provide NASA/Langley Research Center with current information on the use of aircraft in forest fire operations, and to identify research requirements for future operations. A literature survey, interview of forest fire service personnel, analysis and synthesis of data from research reports and independent conclusions, and recommendations for future NASA-LRC programs are included.

  6. Validation of a Polyimide Foam Model for Use in Transmission Loss Applications

    NASA Technical Reports Server (NTRS)

    Hong, Kwanwoo; Bolton, J. Stuart; Cano, Roberto J.; Weiser, Erik S.; Jensen, Brian J.; Silcox, Rich; Howerton, Brian M.; Maxon, John; Wang, Tongan; Lorenzi, Tyler

    2010-01-01

    The work described in this paper was focused on the use of a new polyimide foam in a double wall sound transmission loss application. Recall that polyimide foams are functionally attractive, compared to polyurethane foams, for example, owing to their fire resistance. The foam considered here was found to have a flow resistivity that was too high for conventional acoustical applications, and as a result, it was processed by partial crushing to lower the flow resistivity into an acceptable range. Procedures for measuring the flow resistivity and Young s modulus of the material have been described, as was an inverse characterization procedure for estimating the remaining Biot parameters based on standing wave tube measurements of transmission loss and absorption coefficient. The inverse characterization was performed using a finite element model implementation of the Biot poro-elastic material theory. Those parameters were then used to predict the sound transmission loss of a double panel system lined with polyimide foam, and the predictions were compared with full-scale transmission loss measurements. The agreement between the two was reasonable, especially in the high and low frequency limits; however, it was found that the SEA model resulted in an under-prediction of the transmission loss in the mid-frequency range. Nonetheless, it was concluded that the performance of polyimide foam could be predicted using conventional poro-elastic material models and that polyimide foam may offer an attractive alternative to other double wall linings in certain situations: e.g., when fire resistance is a key issue. Future work will concentrate on reducing the density of the foam to values similar to those used in current aircraft sidewall treatments, and developing procedures to improve the performance of the foam in transmission loss applications.

  7. Inhalation toxicology. V., Evaluation of relative toxicity to rats of thermal decomposition products from two aircraft seat fire-blocking materials.

    DOT National Transportation Integrated Search

    1985-11-01

    Two fire-blocking layer (FBL) materials, designed to delay the thermal decomposition of polyurethane foam seat cushions during an aircraft cabin fire, were evaluated for the relative toxicity of their gaseous combustion products. Each materials was t...

  8. 46 CFR 189.55-5 - Plans and specifications required for new construction.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., the arrangement of the alarm and extinguishing systems, the fire extinguishers, means of access to... other fire control features. (3) Details of alarm systems. (4) Details of extinguishing systems, including fire mains, carbon dioxide, clean agent, foam, and sprinkling systems. (e) Marine engineering. For...

  9. 46 CFR 189.55-5 - Plans and specifications required for new construction.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., the arrangement of the alarm and extinguishing systems, the fire extinguishers, means of access to... other fire control features. (3) Details of alarm systems. (4) Details of extinguishing systems, including fire mains, carbon dioxide, clean agent, foam, and sprinkling systems. (e) Marine engineering. For...

  10. Flame Resistant Foam

    NASA Technical Reports Server (NTRS)

    1984-01-01

    Solimide manufactured by Imi-Tech Corporation, is a lightweight fire resistant material produced under a manufacturing process that allows it to be uniformly foamed. Can be produced in a variety of densities and structural configurations and remains resilient under exposure to temperatures ranging from minus 300 to plus 500 degrees Fahrenheit. Is resistant to open flame and generates virtually no smoke or toxic by-products. Used in aircraft for its superior damping characteristics, lighter weight and fire barrier properties, it's also applicable to ships and surface transportation systems such as transit cars, trains, buses and automobiles.

  11. 29 CFR 1910.163 - Fixed extinguishing systems, water spray and foam.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ....160. This section does not apply to automatic sprinkler systems which are covered under § 1910.159. (b...] Other Fire Protection Systems ... 29 Labor 5 2012-07-01 2012-07-01 false Fixed extinguishing systems, water spray and foam. 1910.163...

  12. 29 CFR 1910.163 - Fixed extinguishing systems, water spray and foam.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ....160. This section does not apply to automatic sprinkler systems which are covered under § 1910.159. (b...] Other Fire Protection Systems ... 29 Labor 5 2014-07-01 2014-07-01 false Fixed extinguishing systems, water spray and foam. 1910.163...

  13. 46 CFR 160.035-1 - Applicable specifications.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Laminates, Fibrous Glass Reinforced, Marine Structural. MIL-P-19644—Plastic Foam, Molded Polystyrene..., Polyester, Low Pressure Laminating, Fire Retardant. MIL-P-21929—Plastic Material, Cellular Polyurethane, Rigid, Foam-In-Place, Low Density. (3) Federal specifications: TT-P-59—Paint, Ready-Mixed, International...

  14. 46 CFR 160.035-1 - Applicable specifications.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Laminates, Fibrous Glass Reinforced, Marine Structural. MIL-P-19644—Plastic Foam, Molded Polystyrene..., Polyester, Low Pressure Laminating, Fire Retardant. MIL-P-21929—Plastic Material, Cellular Polyurethane, Rigid, Foam-In-Place, Low Density. (3) Federal specifications: TT-P-59—Paint, Ready-Mixed, International...

  15. Guide Specification For Small, Dual Agent Aircraft Rescue and Firefighting Vehicles

    DOT National Transportation Integrated Search

    1993-12-07

    This advisory circular (AC) contains performance standards, specifications, and : recommendations for the design, construction, and testing of a family of small, : dual agent aircraft rescue and fire fighting (ARFF) vehicles. The National : Fire Prot...

  16. Applicability of ISO 16697 Data to Spacecraft Fire Fighting Strategies

    NASA Technical Reports Server (NTRS)

    Hirsch, David B.; Beeson, Harold D.

    2012-01-01

    Presentation Agenda: (1) Selected variables affecting oxygen consumption during spacecraft fires, (2) General overview of ISO 16697, (3) Estimated amounts of material consumed during combustion in typical ISS enclosures, (4) Discussion on potential applications.

  17. When the Fire's Out: Learning from Adversity.

    ERIC Educational Resources Information Center

    Holden, Tom

    1997-01-01

    After a $7 million arson fire destroyed part of a Virginia Beach high school, about 1,200 students were temporarily relocated to a refurbished former mini-mall, and a 16-month recovery project was initiated. The new design improved library and art facilities. School officials have since learned to fight fire with simple precautions, such as…

  18. New fire-fighting water bucket is lifted by helicopter

    NASA Technical Reports Server (NTRS)

    2000-01-01

    A NASA helicopter lifts a high-impact-resistant flexible plastic bucket that will be used for fire protection on property and buildings at Kennedy Space Center. Known as the 'Bambi' bucket, the 324-gallon container will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.

  19. 46 CFR 153.975 - Preparation for cargo transfer.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... system to have a fire protection system. (b) Any electrical bonding of the tankship to the transfer... plugged. (m) Smoking is limited to safe places. (n) Fire fighting and safety equipment is ready. (o) He is... or continue cargo transfer unless the following conditions are met: (a) No fires or open flames are...

  20. Development of a Minimum Performance Standard for Hand-Held Fire Extinguishers as a Replacement for Halon 1211 on Civilian Transport Category Aircraft

    NASA Astrophysics Data System (ADS)

    Webster, Harry

    2002-08-01

    One or more Halon 1211 hand-held fire extinguishers are specified in Federal Aviation Regulation (FAR) Part 25.851 as a requirement on transport category aircraft with 31 or more seats. Halon 1211 has been linked to the destruction of the ozone layer and production of new Halon 1211 has been halted per the Montreal Protocol in 1993. The phase out of Halon 1211, as the hand-held firefighting agent of choice, for civilian transport category aircraft has necessitated the development of a Minimum Performance Standard (MPS) to evaluate replacement agents. The purpose of the MPS is to insure that there is no reduction in safety, both in terms of effectiveness in fighting onboard fires and toxicity to the passengers and crew. The MPS specifies two new tests that replacement agents must pass in addition to requiring national certifications such as provided by Underwriters Laboratories. The first test evaluates the "flooding" characteristics of the agent against a hidden in-flight fire. This test determines the ability of a streaming agent to function as a flooding agent. The second test evaluates the performance of the agent in fighting a terrorist fire scenario and the associated toxicity hazard. This test measures the agent's ability to extinguish a triple-seat fire in an aircraft cabin under in-flight conditions and the toxicity characteristics of both the neat agent and the products of decomposition. This MPS will insure that the replacement agents will meet or exceed the performance of Halon 1211 both in fighting fires and maintaining a safe breathing environment in aircraft cabins.

  1. Comparison of Carbon Dioxide and Helium as Fire Extinguishing Agents for Spacecraft

    NASA Technical Reports Server (NTRS)

    Gokoglu, Suleyman; Son, Youngjin; Ronney, Paul D.

    2004-01-01

    The effects of radiation heat transfer in microgravity compared to convection heat transfer in earth gravity for opposed-flow (downward) over thermally-thick fuel using low density foam fuel were investigated. Microgravity experiments on flame spread over thermally-thick fuels were conducted using foam fuels to obtain low density and thermal conductivity, and thus large flame spread rate compared to dense fuels such as PMMA. And thereby valid microgravity results were obtained even in 2.2 second drop-tower experiments not to mention for the longer duration tests in Zero Gravity Facility. Contrast to the conventional understanding, it was found that steady flame spread can occur over thick fuels in quiescent microgravity environments, especially when radiatively-active diluent gases such as CO2 were employed. This is proposed to result from radiative heat transfer from the flame to the fuel surface, which could lead to steady spread even when the amount of the heat transfer via conduction from the flame to the fuel bed is negligible. Radiative effects are more significant at microgravity conditions because the flame is thicker and thus the volume of radiating combustion products is larger as well. These results suggested that helium may be a better inert or extinguishment agent on both a mass and a mole bases at microgravity even though CO2 is much better on a mole bases at earth gravity, and these are relevant to studies of fire safety in manned spacecraft, particularly the International Space Station that uses CO2 fire extinguishers. CO2 may not be as effective as an extinguishing agent at microgravity as it is at earth gravity in some conditions because of the differences in spread mechanisms between the two cases. In particular, the difference between conduction-dominated heat transport to the fuel bed at earth gravity and radiation-dominated heat transport at microgravity indicates that radiatively-inert diluent such as helium could be preferable in microgravity applications. Helium may be a superior fire suppression agent at microgravity on several bases. First, helium is more effective than CO2 on a mole basis (thus pressure times storage volume basis) at microgravity, meaning that the size and weight of storage bottles would be smaller for the same fire-fighting capability. Second; helium is much more effective on a mass basis (by about 11 times) at microgravity. Third; helium has no physiological activity, unlike CO2 that affects human respiration. Fourth, as compared to N2 or CO2, is not very soluble in water and thus has fewer tendencies to cause bloodstream bubble formation following rapid spacecraft cabin depressurization.

  2. Comparison of Carbon Dioxide and Helium as Fire Extinguishing Agents for Spacecraft

    NASA Technical Reports Server (NTRS)

    Gokoglu, Suleyman; Son, Youngjin; Ronney, Paul D.

    2004-01-01

    The effects of radiation heat transfer in microgravity compared to convection heat transfer in earth gravity for opposed-flow (downward) over thermally-thick fuel using low density foam fuel were investigated. Microgravity experiments on flame spread over thermally-thick fuels were conducted using foam fuels to obtain low density and thermal conductivity, and thus large flame spread rate compared to dense fuels such as PMMA. And thereby valid microgravity results were obtained even in 2.2 second drop-tower experiments not to mention for the longer duration tests in Zero Gravity Facility. Contrast to the conventional understanding, it was found that steady flame spread can occur over thick fuels in quiescent microgravity environments, especially when radiatively-active diluent gases such as CO2 were employed. This is proposed to result from radiative heat transfer from the flame to the fuel surface, which could lead to steady spread even when the amount of the heat transfer via conduction from the flame to the fuel bed is negligible. Radiative effects are more significant at microgravity conditions because the flame is thicker and thus the volume of radiating combustion products is larger as well. These results suggested that helium may be a better inert or extinguishment agent on both a mass and a mole bases at microgravity even though CO2 is much better on a mole bases at earth gravity, and these are relevant to studies of fire safety in manned spacecraft, particularly the International Space Station that uses CO2 fire extinguishers. CO2 may not be as effective as an extinguishing agent at g as it is at earth gravity in some conditions because of the differences in spread mechanisms between the two cases. In particular, the difference between conduction-dominated heat transport to the fuel bed at earth gravity and radiation-dominated heat transport at g indicates that radiatively-inert diluent such as helium could be preferable in g applications. Helium may be a superior fire suppression agent at g on several bases. First, helium is more effective than CO2 on a mole basis (thus pressure times storage volume basis) at g, meaning that the size and weight of storage bottles would be smaller for the same fire-fighting capability. Second; helium is much more effective on a mass basis (by about 11 times) at g. Third; helium has no physiological activity, unlike CO2 that affects human respiration. Fourth, as compared to N2 or CO2, is not very soluble in water and thus has fewer tendencies to cause bloodstream bubble formation following rapid spacecraft cabin depressurization.

  3. Mesoscale Simulations During the Double Trouble State Park Wildfire in East-Central New Jersey on June 2, 2002

    Treesearch

    Joseph J. Charney; Xindi Bian; Brian E. Potter; Warren E. Heilman

    2003-01-01

    The 2000 fire season brought to the forefront the issue of severe wildland fires in the United States. To address the need for new research and for the development of predictive tools for the management of wildland fires, Congress allocated funding under the National Fire Plan (NFP) to better equip government agencies to fight and study forest fires. As part of the NFP...

  4. Bridging EOS remote sensing measurements and fire emissions, smoke dispersion, and air quality DSS in the Eastern US

    Treesearch

    John J. Qu; Xianjun Hao; Ruixin Yang; Swarvanu Dasgupta; Sanjeeb Bhoi; Menas Kafatos

    1999-01-01

    Fire eniissions, smoke dispersiotl. ancl air quality are very important for fire fighting and planing of prescribed burning. BlueskyRATNS (BSR) is a comprehenisive and state-of-the-art Decision Support System (DSS) for fire managers and air quality managers to plan fiiels treatments and support state air qiiality smoke regulatory actions, especially related to...

  5. New fire-fighting water bucket releases its water for a demonstration

    NASA Technical Reports Server (NTRS)

    2000-01-01

    A NASA helicopter releases 324 gallons of water onto a building in a simulated fire control demonstration. The high-impact- resistant flexible plastic bucket will be used for fire protection on property and buildings at Kennedy Space Center. Known as the 'Bambi' bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.

  6. 46 CFR 76.17-1 - Application.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Application. 76.17-1 Section 76.17-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Foam Extinguishing Systems, Details § 76.17-1 Application. (a) Where a foam extinguishing system is installed, the...

  7. 46 CFR 76.17-1 - Application.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 3 2011-10-01 2011-10-01 false Application. 76.17-1 Section 76.17-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Foam Extinguishing Systems, Details § 76.17-1 Application. (a) Where a foam extinguishing system is installed, the...

  8. 46 CFR 95.17-1 - Application.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Application. 95.17-1 Section 95.17-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Foam Extinguishing Systems, Details § 95.17-1 Application. (a) Where a foam extinguishing system...

  9. 46 CFR 95.17-1 - Application.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Application. 95.17-1 Section 95.17-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Foam Extinguishing Systems, Details § 95.17-1 Application. (a) Where a foam extinguishing system...

  10. Fighting the Fire in Our Own House: How Poor Decisions are Smoldering Within the U.S. Fire Service

    DTIC Science & Technology

    Additionally, a second recommendation suggests incorporating an anonymous near-miss reporting system to identify workplace incidents that fall short of an accident, but nonetheless contain pertinent educational information.

  11. 30 CFR 75.1908 - Nonpermissible diesel-powered equipment; categories.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the mine fire fighting and evacuation plan under § 75.1502. [61 FR 55527, Oct. 25, 1996; 70 FR 36347... such machine or device, which job site is occupied by a miner. (d) Diesel-powered ambulances and fire...

  12. KSC00pp0744

    NASA Image and Video Library

    2000-06-02

    A NASA helicopter takes off to bring water to fight a small fire on Kennedy Space Center grounds. The site is between Kennedy Parkway North and the Indian River. The fire is one of many throughout Central Florida, which is suffering from drought

  13. KSC-00pp0744

    NASA Image and Video Library

    2000-06-02

    A NASA helicopter takes off to bring water to fight a small fire on Kennedy Space Center grounds. The site is between Kennedy Parkway North and the Indian River. The fire is one of many throughout Central Florida, which is suffering from drought

  14. Improved fire resistant radio frequency anechoic materials

    NASA Technical Reports Server (NTRS)

    Robinson, D. A.

    1969-01-01

    Protective, flameproof foam covering improves the resistance to fire and surface contamination of low-cost radio frequency absorbing and shielding anechoic materials. This promotes safety of operating personnel and equipment being tested in an otherwise combustible anechoic chamber.

  15. Effects of fire retardant chemical and fire suppressant foam on shrub steppe vegetation in northern Nevada

    USGS Publications Warehouse

    Larson, Diane L.; Newton, Wesley E.; Anderson, Patrick J.; Stein, Steven J.

    1999-01-01

    The objectives of this study were to determine the effects of fire retardantchemical (Phos-Chek G75-F*) and fire suppressant foam (Silv-Ex) application,alone and in combination with fire, on Great Basin shrub steppe vegetation. Wemeasured growth, resprouting, flowering, and incidence of galling insects onChrysothamnus viscidiflorusandArtemisia tridentata. These characteristics were notaffected by any chemical treatment. We measured community characteristics,including species richness, evenness, and diversity, and number of stems ofwoody and herbaceous plants in riparian and upland plots. Of these characteristics, only species richness and number ofstems/m2 clearly responded to the chemicaltreatments, and the response was modified by fire. In general, speciesrichness declined, especially after Phos-Chek application. However, by the endof the growing season, species richness did not differ between treated andcontrol plots. Acanonical variate analysis suggested that burning had agreater influence on community composition than did the chemical treatments.In general, riparian areas showed more significant responses to the treatmentsthan did upland areas, and June applications produced greater changes inspecies richness and stem density than did July applications.

  16. 46 CFR 108.471 - Water pump.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Water pump. 108.471 Section 108.471 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Foam Extinguishing Systems § 108.471 Water pump. Each water pump in a foam extinguishing...

  17. 46 CFR 108.471 - Water pump.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Water pump. 108.471 Section 108.471 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Foam Extinguishing Systems § 108.471 Water pump. Each water pump in a foam extinguishing...

  18. 46 CFR 167.45-50 - Foam smothering system requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 167.45-50 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS PUBLIC NAUTICAL SCHOOL SHIPS Special Firefighting and Fire Prevention Requirements § 167.45-50 Foam smothering... deep in not more than 3 minutes. The arrangement of piping shall be such as to give a uniform...

  19. 46 CFR 167.45-50 - Foam smothering system requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 167.45-50 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS PUBLIC NAUTICAL SCHOOL SHIPS Special Firefighting and Fire Prevention Requirements § 167.45-50 Foam smothering... deep in not more than 3 minutes. The arrangement of piping shall be such as to give a uniform...

  20. 46 CFR 167.45-50 - Foam smothering system requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 167.45-50 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS PUBLIC NAUTICAL SCHOOL SHIPS Special Firefighting and Fire Prevention Requirements § 167.45-50 Foam smothering... deep in not more than 3 minutes. The arrangement of piping shall be such as to give a uniform...

  1. 46 CFR 167.45-50 - Foam smothering system requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 167.45-50 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS PUBLIC NAUTICAL SCHOOL SHIPS Special Firefighting and Fire Prevention Requirements § 167.45-50 Foam smothering... deep in not more than 3 minutes. The arrangement of piping shall be such as to give a uniform...

  2. 46 CFR 167.45-50 - Foam smothering system requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 167.45-50 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS PUBLIC NAUTICAL SCHOOL SHIPS Special Firefighting and Fire Prevention Requirements § 167.45-50 Foam smothering... deep in not more than 3 minutes. The arrangement of piping shall be such as to give a uniform...

  3. 46 CFR 108.471 - Water pump.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Water pump. 108.471 Section 108.471 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Foam Extinguishing Systems § 108.471 Water pump. Each water pump in a foam extinguishing...

  4. 46 CFR 108.471 - Water pump.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Water pump. 108.471 Section 108.471 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Foam Extinguishing Systems § 108.471 Water pump. Each water pump in a foam extinguishing...

  5. 46 CFR 108.471 - Water pump.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Water pump. 108.471 Section 108.471 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Foam Extinguishing Systems § 108.471 Water pump. Each water pump in a foam extinguishing...

  6. New fire-fighting water bucket is readied for a demonstration

    NASA Technical Reports Server (NTRS)

    2000-01-01

    Workers attach a high-impact-resistant flexible plastic bucket to a NASA helicopter. Holding 324 gallons of water, it will be used for fire protection on property and buildings at Kennedy Space Center. Known as the 'Bambi' bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.

  7. New fire-fighting water bucket is filled for demonstration

    NASA Technical Reports Server (NTRS)

    2000-01-01

    - A NASA helicopter hovers over the water while a high-impact- resistant flexible plastic bucket fills. The 324-gallon container will be used for fire protection on property and buildings at Kennedy Space Center. Known as the 'Bambi' bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.

  8. New fire-fighting water bucket is lifted from water for a demonstration

    NASA Technical Reports Server (NTRS)

    2000-01-01

    A NASA helicopter lifts a high-impact-resistant flexible plastic bucket filled with water. The container will be used for fire protection on property and buildings at Kennedy Space Center.. Known as the 'Bambi' bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.

  9. Firefighting Trainer

    NASA Technical Reports Server (NTRS)

    1984-01-01

    Firefighting trainees conduct fire control exercises using a prototype simulator known as the Emergency Management Computer Aided Training System (EMCAT). Developed by Marshall Space Flight Center (MFS) in response to a request from the Huntsville (AL) Fire Department, EMCAT enables a trainee to assume the role of fireground commander and make quick decisions on best use of his fire fighting personnel and equipment.

  10. Integrated Personal Protective Equipment Standards Support Model

    DTIC Science & Technology

    2008-04-01

    traditional SCBA showed that the distribution of the weight is important as well. Twelve firefighters performed simulated fire -fighting and rescue exercises...respiratory equipment standards and five National Fire Protection Association (NFPA) protective suit, clothing, and respirator standards. The...respirators. The clothing standards were for protective ensembles for urban search and rescue operations, open circuit SCBA for fire and emergency

  11. Proceedings of the symposium on fire and watershed management

    Treesearch

    Neil H. Berg

    1989-01-01

    Wildfires have affected the landscape since the dawn of time and will continue to do so for the foreseeable future. Policies and practices in response to fire have varied, however, contingent upon a complex mix of values and attitudes overlaid by the technical acumen available to both "fight" the fire and reclaim the land afterwards.

  12. KSC-00pp1080

    NASA Image and Video Library

    2000-08-08

    A NASA helicopter flies over fire-fighting equipment and personnel in order to drop its load of water on a wildfire at KSC. Before being extinguished, the fire burned about 20 acres at a site near gate 2C on Kennedy Parkway North (route 3)

  13. KSC00pp1080

    NASA Image and Video Library

    2000-08-08

    A NASA helicopter flies over fire-fighting equipment and personnel in order to drop its load of water on a wildfire at KSC. Before being extinguished, the fire burned about 20 acres at a site near gate 2C on Kennedy Parkway North (route 3)

  14. Fire/security staff member instructs STS-29 crew on fire extinguisher usage

    NASA Technical Reports Server (NTRS)

    1988-01-01

    STS-29 Discovery, Orbiter Vehicle (OV) 103, crewmembers are trained in procedures to follow in the event of a fire. Here, the crew is briefed on the correct handling of the fire extinguisher by Robert Fife (far left) of NASA's fire / security staff. Pictured, left to right are Pilot John E. Blaha, Commander Michael L. Coats, Mission Specialist (MS) Robert C. Springer, MS James F. Buchli, and MS James P. Bagian. The in fire fighting training took place at JSC's fire training pit across from the Gilruth Center Bldg 207.

  15. Determination of pumper truck intervention ratios in zones with high fire potential by using geographical information system

    NASA Astrophysics Data System (ADS)

    Aricak, Burak; Kucuk, Omer; Enez, Korhan

    2014-01-01

    Fighting forest fires not only depends on the forest type, topography, and weather conditions, but is also closely related to the technical properties of fire-fighting equipment. Firefighting is an important part of fire management planning. However, because of the complex nature of forests, creating thematic layers to generate potential fire risk maps is difficult. The use of remote sensing data has become an efficient method for the discrete classification of potential fire risks. The study was located in the Central District of the Kastamonu Regional Forest Directorate, covering an area of 24,320 ha, 15,685 ha of which is forested. On the basis of stand age, crown closure, and tree species, the sizes and distributions of potential fire risk zones within the study area were determined using high-resolution GeoEye satellite imagery and geographical information system data. The status of pumper truck intervention in zones with high fire risk and the sufficiency of existing forest roads within an existing forest network were discussed based on combustible matter characteristics. Pumper truck intervention was 83% for high-risk zones, 79% for medium-risk zones, and 78% for low-risk zones. A pumper truck intervention area map along existing roads was also created.

  16. Development of fire-resistant, low smoke generating, thermally stable end items for aircraft and spacecraft

    NASA Technical Reports Server (NTRS)

    Gagliani, J.; Sorathia, U. A. K.; Wilcoxson, A. L.

    1977-01-01

    Materials were developed to improve aircraft interior materials by modifying existing polymer structures, refining the process parameters, and by the use of mechanical configurations designed to overcome specific deficiencies. The optimization, selection, and fabrication of five fire resistant, low smoke emitting open cell foams are described for five different types of aircraft cabin structures. These include: resilient foams, laminate floor and wall paneling, thermal/acoustical insulation, molded shapes, and coated fabrics. All five have been produced from essentially the same polyimide precursor and have resulted in significant benefits from transfer of technology between the various tasks.

  17. Response and legislative changes after the Kiss nightclub tragedy in Santa Maria/RS/Brazil: Learning from a large-scale burn disaster.

    PubMed

    Gragnani, Alfredo; de Oliveira, Andrea Fernandes; Boro, Daniel; Pham, Tam N; Ferreira, Lydia Masako

    2017-03-01

    A major fire occurred on January 27, 2013, at 02:30 at Kiss nightclub in the city of Santa Maria, State of Rio Grande do Sul, in Southern Brazil. In this retrospective report, we aimed to describe the nightclub fire event, its immediate consequences, and evaluated its impact on legislation. Our objective was to disseminate the lessons we learned from this large-scale nightclub fire disaster. We conducted a literature review in PubMed and Lilacs database from 2013 to 2015 related to the nightclub Kiss, Santa Maria, fire, burns, and similar events worldwide over the past 15 years. We searched in the general press and online media information sites, and seeking legislation about this topic at the federal level in Brazil. We reported on the legislation changes that resulted from this nightclub fire. Current federal legislation on fire prevention and the scope of public safety, including night clubs and discos, states is the duty of the state and everyone's responsibility, pursuant to Article 144 of the Federal Constitution of Brazil. Thus, the federal union, individual states and municipalities have the power to legislate on fire prevention, and especially to ensure the security of the population. A state law called "Law Kiss", was passed in 2014, establishing standards on safety, prevention and protection against fire in buildings and areas of fire risk in the state of Rio Grande do Sul. On a national level, a law of prevention and fire fighting in Brazil was also drafted after the Santa Maria disaster (Law project no. 4923, 2013). Currently, this bill is still awaiting sanction before it can take effect. As we push for enactment of the national law of prevention and fire fighting in Brazil, we will continue emphasizing fire prevention, fire protection, fire fighting, means of escape and proper management. All similar events in this and other countries remind us that similar tragedies may occur anywhere, and that the analysis of facts, previous mistakes, during and after the incident are crucial to our understanding, and will help us lessen the chance of future occurrences. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  18. Evaluation of NDI compressed air foam system (cafs) applied as a retrofit. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duncan, S.

    1994-08-01

    Army Engineer Firefighting Detachments require increased firefighting capability to compensate for deficiencies in structural, brush, or wildland and large petroleum storage site fires. Additionally, Army fire departments responsible for protection and prevention on posts, camps and stations have difficulty accessing new or emerging technology do not possess state-of-the-art equipment. The results of this evaluation and subsequent projects, will be reported throughout the Army in an attempt to mitigate operational deficiencies and widen the scope of knowledge in the Army fire service. The evaluation of non-developmental retrofitted compressed air foam systems show an efficiency of suppressive capabilities of water superseded bymore » water alone. Retrofitting the equipment was not easy or inexpensive but it was very successful.« less

  19. 30 CFR 57.4200 - General requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Equipment § 57.4200 General requirements. (a) For fighting fires that could endanger...

  20. 30 CFR 56.4200 - General requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Equipment § 56.4200 General requirements. (a) For fighting fires that could endanger...

  1. KSC00pp1078

    NASA Image and Video Library

    2000-08-08

    A NASA helicopter dips its fire-fighting bucket into the river to pick up and deliver a cargo of water to a wildfire at KSC. Before being extinguished, the fire burned about 20 acres at a site near gate 2C on Kennedy Parkway North (route 3)

  2. KSC-00pp1078

    NASA Image and Video Library

    2000-08-08

    A NASA helicopter dips its fire-fighting bucket into the river to pick up and deliver a cargo of water to a wildfire at KSC. Before being extinguished, the fire burned about 20 acres at a site near gate 2C on Kennedy Parkway North (route 3)

  3. NASA helicopter helps fight brush fire at KSC

    NASA Technical Reports Server (NTRS)

    2000-01-01

    A NASA helicopter flies toward the source of the smoke to drop its load of water on a wildfire at KSC. Before being extinguished, the fire burned about 20 acres at a site near gate 2C on Kennedy Parkway North (route 3).

  4. 46 CFR 12.05-3 - General requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... applicant must: (1) Be at least 18 years of age; (2) Pass the prescribed physical and medical examination in... § 12.01-3). (2) Fire prevention and fire-fighting as set out in table A-VI/1-2 of the STCW Code. (3...

  5. 46 CFR 12.05-3 - General requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... applicant must: (1) Be at least 18 years of age; (2) Pass the prescribed physical and medical examination in... § 12.01-3). (2) Fire prevention and fire-fighting as set out in table A-VI/1-2 of the STCW Code. (3...

  6. 48 CFR 452.236-77 - Emergency Response.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Response. As prescribed in 436.577, the following clause may be used in Forest Service construction contracts: Emergency Response (NOV 1996) (a) Contractor's Responsibility for Fire Fighting. (1) The..., Equipment, Utilities, and Improvements, shall immediately extinguish all fires on the work site other than...

  7. 48 CFR 452.236-77 - Emergency Response.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Response. As prescribed in 436.577, the following clause may be used in Forest Service construction contracts: Emergency Response (NOV 1996) (a) Contractor's Responsibility for Fire Fighting. (1) The..., Equipment, Utilities, and Improvements, shall immediately extinguish all fires on the work site other than...

  8. 48 CFR 452.236-77 - Emergency Response.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Response. As prescribed in 436.577, the following clause may be used in Forest Service construction contracts: Emergency Response (NOV 1996) (a) Contractor's Responsibility for Fire Fighting. (1) The..., Equipment, Utilities, and Improvements, shall immediately extinguish all fires on the work site other than...

  9. 48 CFR 452.236-77 - Emergency Response.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Response. As prescribed in 436.577, the following clause may be used in Forest Service construction contracts: Emergency Response (NOV 1996) (a) Contractor's Responsibility for Fire Fighting. (1) The..., Equipment, Utilities, and Improvements, shall immediately extinguish all fires on the work site other than...

  10. 48 CFR 452.236-77 - Emergency Response.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Response. As prescribed in 436.577, the following clause may be used in Forest Service construction contracts: Emergency Response (NOV 1996) (a) Contractor's Responsibility for Fire Fighting. (1) The..., Equipment, Utilities, and Improvements, shall immediately extinguish all fires on the work site other than...

  11. Fire suppression in human-crew spacecraft

    NASA Technical Reports Server (NTRS)

    Friedman, Robert; Dietrich, Daniel L.

    1991-01-01

    Fire extinguishment agents range from water and foam in early-design spacecraft (Halon 1301 in the present Shuttle) to carbon dioxide proposed for the Space Station Freedom. The major challenge to spacecraft fire extinguishment design and operations is from the micro-gravity environment, which minimizes natural convection and profoundly influences combustion and extinguishing agent effectiveness, dispersal, and post-fire cleanup. Discussed here are extinguishment in microgravity, fire-suppression problems anticipated in future spacecraft, and research needs and opportunities.

  12. 46 CFR 25.30-10 - Hand-portable fire extinguishers and semi-portable fire-extinguishing systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ....30-10(C): Table 25.30-10(C) Classification Foam, liters (gallons) Carbon dioxide, kilograms (pounds... tampering or use when broken) are not intact, the boarding officer or marine inspector will inspect such...

  13. 46 CFR 25.30-10 - Hand-portable fire extinguishers and semi-portable fire-extinguishing systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ....30-10(C): Table 25.30-10(c) Classification Foam, liters (gallons) Carbon dioxide, kilograms (pounds... tampering or use when broken) are not intact, the boarding officer or marine inspector will inspect such...

  14. 46 CFR 25.30-10 - Hand-portable fire extinguishers and semi-portable fire-extinguishing systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ....30-10(C): Table 25.30-10(c) Classification Foam, liters (gallons) Carbon dioxide, kilograms (pounds... tampering or use when broken) are not intact, the boarding officer or marine inspector will inspect such...

  15. 46 CFR 25.30-10 - Hand-portable fire extinguishers and semi-portable fire-extinguishing systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ....30-10(C): Table 25.30-10(c) Classification Foam,liters (gallons) Carbon dioxide, kilograms (pounds... tampering or use when broken) are not intact, the boarding officer or marine inspector will inspect such...

  16. 46 CFR 25.30-10 - Hand-portable fire extinguishers and semi-portable fire-extinguishing systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ....30-10(C): Table 25.30-10(c) Classification Foam,liters (gallons) Carbon dioxide, kilograms (pounds... tampering or use when broken) are not intact, the boarding officer or marine inspector will inspect such...

  17. Acute toxicity of firefighting chemical formulations to four life stages of fathead minnow

    USGS Publications Warehouse

    Gaikowski, Mark P.; Hamilton, Steve J.; Buhl, Kevin J.; McDonald, Susan F.; Summers, Cliff H.

    1996-01-01

    Laboratory studies were conducted with four early life stages of fathead minnow,Pimephales promelas,to determine the acute toxicity of five firefighting chemical formulations in standardized soft and hard water. Egg, fry, 30-day posthatch, and 60-day posthatch life stages were tested with three fire retardants (Fire-Trol GTS-R, Fire-Trol LCG-R, and Phos-Chek D75-F) and two fire-suppressant foams (Phos-Chek WD-881 and Ansul Silv-Ex). Fry were generally the most sensitive life stage tested, whereas the eggs were the least sensitive life stage. Formulation toxicity was greater in hard water than in soft water for all life stages tested. Fire-suppressant foams were more toxic than the fire retardants. The 96-hr LC50s derived for fathead minnows were rank ordered from the most toxic to the least toxic formulation as follows: Phos-Chek WD-881 (13a??32 mg/liter) > Silv-Ex (19a??32 mg/liter) > Fire-Trol GTS-R (135a??787 mg/liter) > Phos-Chek D75-F (168a??2250 mg/liter) > Fire-Trol LCG-R (519a??6705 mg/liter) (ranges are the lowest and highest 96-hr LC50for each formulation). (C) 1996 Academic Press, Inc.

  18. Building systems and smoke control

    NASA Astrophysics Data System (ADS)

    Kawagoe, K.; Wakamatsu, T.; Morishita, Y.; Yamana, T.

    The cost effectiveness of different approaches to fire prevention - sprinklers and detectors, increased use of smoke control devices, increased flammability standards, increased public education, increase fire prevention efforts, increased public fire services, etc. - need to be studied further as a guide to determining the emphasis appropriate for each. It is clear that detectors and sprinklers are making a difference in the fight to reduce fire losses. With continued effort the detectors' and sprinklers' full potential for saving lives and property from fire can be realized.

  19. Stennis acquires new ladder truck

    NASA Image and Video Library

    2009-10-20

    The Stennis Space Center Fire Department added to its fire-fighting capabilities with acquisition of a new emergency response vehicle, Ladder-1, for use on-site. The E-One HP78 Aerial Truck is a combination aerial ladder and fire suppression unit and is designed with the latest safety technology. Featuring a 78-foot ladder and a pumping capability of 1,500 gallons per minute, the new truck provides firefighters with a tremendous rescue and fire suppression tool, Stennis Fire Chief Clark Smith said.

  20. Fire fighting and its influence on the body.

    PubMed

    Rossi, René

    2003-08-15

    Working conditions for fire fighters can be described according to the environment temperature and the incident radiant heat flux. Measurements for this study in buildings for fire fighting training have shown that fire fighters are typically exposed to radiant heat fluxes of between 5 and 10 kWm(-2) during this kind of exercise. The heat load can nevertheless be much higher. In one case, 42 kWm(-2) was measured. The temperatures reached between 100 and 190 degrees C at 1 m above ground, going up to 278 degrees C in one case. Human trials have been performed with 17 fire fighters. After exercises (about 15 min) in a heated room, the mean core temperature of the fire fighters rose by 0.6 degrees C with a surrounding temperature of 31 degrees C and 1.0 degrees C with 38 degrees C. The sweat production varied from 0.7 to 2.1 lh(-1); 16% to 45% of sweat remained in the clothing layers. During the exercises in the training buildings, a mean of 48 degrees C has been measured between fire fighters' clothing and workwear. These conditions lead to an increase of the relative humidity in all the jackets up to 100%. When the fire fighters came out of the fire, the humidity remained at this level in the PVC coated jackets while it was in some cases strongly reduced in breathable jackets.

  1. 46 CFR 95.05-10 - Fixed fire extinguishing systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... in special cases: (1) A fixed foam system may be used in cargo tanks. (2) A water sprinkling system.... Alternately, the Commandant may permit the installation of an approved water sprinkler system or other... is contracted for on or after November 19, 1952, a fixed carbon dioxide, foam, or water spray system...

  2. 46 CFR 95.05-10 - Fixed fire extinguishing systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... in special cases: (1) A fixed foam system may be used in cargo tanks. (2) A water sprinkling system.... Alternately, the Commandant may permit the installation of an approved water sprinkler system or other... is contracted for on or after November 19, 1952, a fixed carbon dioxide, foam, or water spray system...

  3. 46 CFR 95.05-10 - Fixed fire extinguishing systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... in special cases: (1) A fixed foam system may be used in cargo tanks. (2) A water sprinkling system.... Alternately, the Commandant may permit the installation of an approved water sprinkler system or other... is contracted for on or after November 19, 1952, a fixed carbon dioxide, foam, or water spray system...

  4. 46 CFR 95.05-10 - Fixed fire extinguishing systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... in special cases: (1) A fixed foam system may be used in cargo tanks. (2) A water sprinkling system.... Alternately, the Commandant may permit the installation of an approved water sprinkler system or other... is contracted for on or after November 19, 1952, a fixed carbon dioxide, foam, or water spray system...

  5. Fire suppression system of a small-scale LNG loading facility at PT Badak NGL

    NASA Astrophysics Data System (ADS)

    Yustiarza, Farhan Hilmyawan

    2017-03-01

    LNG progressively become favorable energy to replace oil-based fuel due to lower cost and more environment-friendly. In order to support an emerging LNG demands in Kalimantan, PT Badak NGL, one of the leading LNG Company in the world, develops the land-transported LNG loading facility. This facility performs loading the LNG into a small-scale tank (ISO Tank) with 20 m3 capacities. Safety reviews over this facility were conducted. Based on these reviews, the LNG filling station requires supplemental safeguards, such as LNG spill containment and firefighting foam system besides firewater system and dry chemical system. The spill containment provides holding LNG spill within the limits of plant property, while the high expansion foam system deals to minimize the vaporization rate to prevent a fire incident. This paper mainly discusses designing of such supplemental safeguards. The requirement of the spill containment is 20 m3 (6.3 × 3.3 × 2.0) m and the foam system should be capable generating foam at least 40 m3/min.

  6. Fighting fire with fire: estimating the efficacy of wildfire mitigation programs using propensity scores

    Treesearch

    David T. Butry

    2009-01-01

    This paper examines the effect wildfire mitigation has on broad-scale wildfire behavior. Each year, hundreds of million of dollars are spent on fire suppression and fuels management applications, yet little is known, quantitatively, of the returns to these programs in terms of their impact on wildfire extent and intensity. This is especially true when considering that...

  7. Fighting forest fires in Brazil

    Treesearch

    José Carlos Mendes de Morais

    2013-01-01

    Fire has been used in Brazil for many years, but the increased use of this tool, combined with natural events and the presence of large forest and agricultural areas, has led to a significant jump in the number of forest fires, most of them caused by accident. To optimize existing resources and to cope with growing demand, action levels were adopted according to the...

  8. Aircraft Instrument, Fire Protection, Warning, Communication, Navigation and Cabin Atmosphere Control System (Course Outline), Aviation Mechanics 3 (Air Frame): 9067.04.

    ERIC Educational Resources Information Center

    Dade County Public Schools, Miami, FL.

    This document presents an outline for a 135-hour course designed to familiarize the student with manipulative skills and theoretical knowledge concerning aircraft instrument systems like major flight and engine instruments; fire protection and fire fighting systems; warning systems and navigation systems; aircraft cabin control systems, such as…

  9. Celebrating Ten Years. Foundation for Individual Rights in Education Annual Report, 2009

    ERIC Educational Resources Information Center

    Foundation for Individual Rights in Education (NJ1), 2009

    2009-01-01

    This paper presents the annual report of the Foundation for Individual Rights in Education (FIRE) for 2009. The year 2009 was momentous for FIRE, for it marked its tenth anniversary. In the last decade, FIRE has been remarkably successful at fighting to secure basic rights of free speech and conscience on college campuses. It has fought for…

  10. New fire-fighting water bucket releases its load for a demonstration.

    NASA Technical Reports Server (NTRS)

    2000-01-01

    A NASA helicopter releases the contents of the high-impact- resistant flexible plastic bucket it holds. The 324-gallon container will be used for fire protection on property and buildings at Kennedy Space Center. Known as the 'Bambi' bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.

  11. Wolf Fire West of Los Angeles

    NASA Technical Reports Server (NTRS)

    2002-01-01

    This photograph taken from the International Space Station on June 7, 2002, shows the Copper Fire burning in the hills outside Los Angeles. Astronauts use a variety of lenses and look angles as their orbits pass over wildfires to document the long-distance movements of smoke from the fires as well as details of the burning areas. This image clearly illustrates the difficult, rugged terrain that firefighters must face when fighting these wildland fires.

  12. Community advisor - firewise

    Treesearch

    Richard D. Reitz

    2003-01-01

    The old model of individual homeowners and neighborhoods depending solely on government provided fire fighting resources is gone. Recent wildland fires have demonstrated that community firefighting resources are easily outpaced when multiple structures are burning simultaneously. The cure is to move most structure protection responsibility to the homeowner and...

  13. Keeping Cool in Extreme Heat

    NASA Technical Reports Server (NTRS)

    2001-01-01

    Through a partnership with Unitika Ltd., NASA's Langley Research Center created a foam based on high temperature resistant polyimide chemistry. Licensed non-exclusively to SORDAL, Inc., the low-density foam, named TEEK, can be processed into forms or used to fill structures such as honeycomb. TEEK offers superior insulation and support qualities, with heat and flame resistance abilities.TEEK is a practical selection for hull insulation in the shipbuilding industry, with numerous potential applications in aerospace applications, fire-resistant construction materials, and a wide range of consumer products that will improve safety and energy efficiency. Other opportunities are available in the areas of automotive coatings and sealants, electrical components, and recreational equipment. SORDAL has introduced its new product in several different forms, under the name "SOLREX". The company is developing a new product called SORDAL Paper(TM) that will be used in conjunction with the polyimide foam to offer thermal protection in various products, such as fire resistant garments and prosthetics.

  14. Potential Impacts of Ultra-High-Pressure (UHP) Technology of National Fire Protection Agency (NFPA) Standard 403 (POSTPRINT)

    DTIC Science & Technology

    2007-06-25

    AFFF tests, and one-tenth the NFPA 403 standard. r 2007 Elsevier Ltd. All rights reserved. Keywords: Aqueous film forming foam ( AFFF ...proven to reduce water- aqueous film forming foam ( AFFF ) agent quantities 2–3 times over conventional water- foam systems on 325–480m2 (3500–5200 ft2...and combined agent firefighting systems (CAFFS) have proven to enhance the performance of firefighting equipment using water and aqueous

  15. Colleges Fight Fire With Electronics.

    ERIC Educational Resources Information Center

    College & University Business, 1968

    1968-01-01

    Description of various electronic fire detection and alarm systems is presented. Explanation of detective systems includes--(1) fixed-temperature and rate-of-rise heat sensitive devices, (2) smoke detective devices, (3) ionization systems, and (4) infrared and ultraviolet radiation devices. Each system type is evaluated in terms of operation,…

  16. 25 CFR 163.28 - Fire management measures.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... wildfire protection needs and extinguish forest or range fires on Indian land. No expenses for fighting a... are currently in use by public and private wildfire protection agencies adjacent to Indian... mutual aid in wildfire protection. This section does not apply to the rendering of emergency aid, or...

  17. 25 CFR 163.28 - Fire management measures.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... wildfire protection needs and extinguish forest or range fires on Indian land. No expenses for fighting a... are currently in use by public and private wildfire protection agencies adjacent to Indian... mutual aid in wildfire protection. This section does not apply to the rendering of emergency aid, or...

  18. 25 CFR 163.28 - Fire management measures.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... wildfire protection needs and extinguish forest or range fires on Indian land. No expenses for fighting a... are currently in use by public and private wildfire protection agencies adjacent to Indian... mutual aid in wildfire protection. This section does not apply to the rendering of emergency aid, or...

  19. 25 CFR 163.28 - Fire management measures.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... wildfire protection needs and extinguish forest or range fires on Indian land. No expenses for fighting a... are currently in use by public and private wildfire protection agencies adjacent to Indian... mutual aid in wildfire protection. This section does not apply to the rendering of emergency aid, or...

  20. 46 CFR 132.210 - Classification.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Classification. 132.210 Section 132.210 Shipping COAST... Portable and Semiportable Fire Extinguishers § 132.210 Classification. (a) Each portable fire extinguisher... Classification Type Size Halon 1211, 1301, and 1211-1301 mixtures kgs. (lbs.) Foam, liters (gallons) Carbon...

  1. 46 CFR 132.210 - Classification.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Classification. 132.210 Section 132.210 Shipping COAST... Portable and Semiportable Fire Extinguishers § 132.210 Classification. (a) Each portable fire extinguisher... Classification Type Size Halon 1211, 1301, and 1211-1301 mixtures kgs. (lbs.) Foam, liters (gallons) Carbon...

  2. 46 CFR 132.210 - Classification.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Classification. 132.210 Section 132.210 Shipping COAST... Portable and Semiportable Fire Extinguishers § 132.210 Classification. (a) Each portable fire extinguisher... Classification Type Size Halon 1211, 1301, and 1211-1301 mixtures kgs. (lbs.) Foam, liters (gallons) Carbon...

  3. 46 CFR 132.210 - Classification.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Classification. 132.210 Section 132.210 Shipping COAST... Portable and Semiportable Fire Extinguishers § 132.210 Classification. (a) Each portable fire extinguisher... Classification Type Size Halon 1211, 1301, and 1211-1301 mixtures kgs. (lbs.) Foam, liters (gallons) Carbon...

  4. 46 CFR 132.210 - Classification.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Classification. 132.210 Section 132.210 Shipping COAST... Portable and Semiportable Fire Extinguishers § 132.210 Classification. (a) Each portable fire extinguisher... Classification Type Size Halon 1211, 1301, and 1211-1301 mixtures kgs. (lbs.) Foam, liters (gallons) Carbon...

  5. Medical evaluation of fire fighters: How fit are they for duty?

    PubMed

    Davis, P O; Biersner, R J; Barnard, R J; Schamadan, J

    1982-08-01

    Aside from the obvious dangers to life and limb associated with the job, fire fighting subjects the body to environmental and physical stressors that can adversely affect various systems. In fact, the effects of these stressors on the cardiovascular system have made coronary heart disease a greater killer among fire fighters than among other occupational groups. The approach to medical evaluation of fire fighters presented here is based on an appreciation of these stressors.

  6. 29 CFR Appendix B to Subpart L of... - National Consensus Standards

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... NFPA No. 13E, Fire Department Operations in Properties Protected by Sprinkler, Standpipe Systems. ANSI..., Water Supplies for Suburban and Rural Fire Fighting. 1910.159 ANSI-NFPA No. 13, Sprinkler Systems. NFPA No. 13A, Sprinkler Systems, Maintenance. ANSI/NFPA No. 18, Wetting Agents. ANSI/NFPA No. 20...

  7. 29 CFR Appendix B to Subpart L of... - National Consensus Standards

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... NFPA No. 13E, Fire Department Operations in Properties Protected by Sprinkler, Standpipe Systems. ANSI..., Water Supplies for Suburban and Rural Fire Fighting. 1910.159 ANSI-NFPA No. 13, Sprinkler Systems. NFPA No. 13A, Sprinkler Systems, Maintenance. ANSI/NFPA No. 18, Wetting Agents. ANSI/NFPA No. 20...

  8. 29 CFR Appendix B to Subpart L of... - National Consensus Standards

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... NFPA No. 13E, Fire Department Operations in Properties Protected by Sprinkler, Standpipe Systems. ANSI..., Water Supplies for Suburban and Rural Fire Fighting. 1910.159 ANSI-NFPA No. 13, Sprinkler Systems. NFPA No. 13A, Sprinkler Systems, Maintenance. ANSI/NFPA No. 18, Wetting Agents. ANSI/NFPA No. 20...

  9. 29 CFR Appendix B to Subpart L of... - National Consensus Standards

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... NFPA No. 13E, Fire Department Operations in Properties Protected by Sprinkler, Standpipe Systems. ANSI..., Water Supplies for Suburban and Rural Fire Fighting. 1910.159 ANSI-NFPA No. 13, Sprinkler Systems. NFPA No. 13A, Sprinkler Systems, Maintenance. ANSI/NFPA No. 18, Wetting Agents. ANSI/NFPA No. 20...

  10. Classical biological control of invasive species: fighting fire with fire

    USDA-ARS?s Scientific Manuscript database

    Invasive species cost the US over $130 billion in losses and control costs every year. Exotic insects, weeds and pathogens are the primary invaders that frequently move across continents, exploding in numbers in areas where they have been newly introduced. There are many reasons that these pests r...

  11. 46 CFR 153.907 - Cargo information.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... exposed to the cargo. (7) A list of fire fighting procedures and extinguishing agents effective with cargo fires. (8) Shipper's name. (9) Loading point. (10) Approximate quantity of cargo. (11) Tank in which the... of these two tables. (2) The name of the cargo prescribed in the letter authorizing carriage of the...

  12. 46 CFR 153.907 - Cargo information.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... exposed to the cargo. (7) A list of fire fighting procedures and extinguishing agents effective with cargo fires. (8) Shipper's name. (9) Loading point. (10) Approximate quantity of cargo. (11) Tank in which the... of these two tables. (2) The name of the cargo prescribed in the letter authorizing carriage of the...

  13. 14 CFR 25.1439 - Protective breathing equipment.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... breathing equipment must be installed for the use of appropriate crewmembers for fighting fires in... dioxide, and other harmful gases while on flight deck duty or while combating fires. (2) The equipment... considered to be of 15-minute duration at the prescribed altitude and minute volume. If a continuous flow...

  14. 46 CFR 153.907 - Cargo information.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... exposed to the cargo. (7) A list of fire fighting procedures and extinguishing agents effective with cargo fires. (8) Shipper's name. (9) Loading point. (10) Approximate quantity of cargo. (11) Tank in which the... of these two tables. (2) The name of the cargo prescribed in the letter authorizing carriage of the...

  15. 14 CFR 25.1439 - Protective breathing equipment.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... breathing equipment must be installed for the use of appropriate crewmembers for fighting fires in... dioxide, and other harmful gases while on flight deck duty or while combating fires. (2) The equipment... considered to be of 15-minute duration at the prescribed altitude and minute volume. If a continuous flow...

  16. Quantification of volatile organic compounds in smoke from prescribed burning and comparison with occupational exposure limits

    NASA Astrophysics Data System (ADS)

    Romagnoli, E.; Barboni, T.; Santoni, P.-A.; Chiaramonti, N.

    2014-05-01

    Prescribed burning represents a serious threat to personnel fighting fires due to smoke inhalation. The aim of this study was to investigate exposure by foresters to smoke from prescribed burning, focusing on exposure to volatile organic compounds (VOCs). The methodology for smoke sampling was first evaluated. Potentially dangerous compounds were identified among the VOCs emitted by smoke fires at four prescribed burning plots located around Corsica. The measured mass concentrations for several toxic VOCs were generally higher than those measured in previous studies due to the experimental framework (short sampling distance between the foresters and the flame, low combustion, wet vegetation). In particular, benzene, phenol and furfural exceeded the legal short-term exposure limits published in Europe and/or the United States. Other VOCs such as toluene, ethybenzene or styrene remained below the exposure limits. In conclusion, clear and necessary recommendations were made for protection of personnel involved in fighting fires.

  17. Fire Protection for Libraries.

    ERIC Educational Resources Information Center

    Fortson-James, Judith

    1981-01-01

    This overview of preventive measures that can be taken to help minimize damage to library materials from fire discusses the advantages, disadvantages, dangers, and comparative costs of several types of sprinkler systems, including high-expansion foam, total-flooding, dry- and wet-pipe systems, and on-off sprinkler heads. Five references are…

  18. 29 CFR 1910.163 - Fixed extinguishing systems, water spray and foam.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Section 1910.163 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR OCCUPATIONAL SAFETY AND HEALTH STANDARDS Fire Protection Fixed Fire... extinguishing agent, installed to meet a particular OSHA standard. These systems shall also comply with § 1910...

  19. 29 CFR 1910.163 - Fixed extinguishing systems, water spray and foam.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Section 1910.163 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR OCCUPATIONAL SAFETY AND HEALTH STANDARDS Fire Protection Fixed Fire... extinguishing agent, installed to meet a particular OSHA standard. These systems shall also comply with § 1910...

  20. Post-processing flame-retardant for polyurethane

    NASA Technical Reports Server (NTRS)

    Monaghan, P.; Sidman, K. R.

    1980-01-01

    Treatment of polyurethane form with elastomer formulation after processing makes foam fire resistant without compromising physical properties. In testing, once ignition source is removed, combustion stops. Treatment also prevents molten particle formation, generates no smoke or toxic gases in fire, and does not deteriorate under prolonged exposure to Sun.

  1. Optimization of aircraft seat cushion fire blocking layers

    NASA Technical Reports Server (NTRS)

    Kourtides, D. A.; Parker, J. A.; Ling, A. C.; Hovatter, W. R.

    1983-01-01

    This report describes work completed by the National Aeronautics and Space Administration - for the Federal Aviation Administration Technical Center. The purpose of this work was to examine the potential of fire blocking mechanisms for aircraft seat cushions in order to provide an optimized seat configuration with adequate fire protection and minimum weight. Aluminized thermally stable fabrics were found to provide adequate fire protection when used in conjunction with urethane foams, while maintaining minimum weight and cost penalty.

  2. Fire research publications, 1983

    NASA Astrophysics Data System (ADS)

    Jason, N. H.

    1984-04-01

    Approximately 130 articles are cited addressing topics in fire fighting and prevention, combustion physics, and fire related hazards. Only publications prepared by members of the Center for Fire Research (CFR), by other National Bureau of Standards (NBS) personnel for CFR, or by external laboratories under contract or grant from the CFR are cited. For documents that are available for purchase from either the Government Printing Office (GPO) or the National Technical Information Service (NTIS), the specific order number has been included in the citation.

  3. Fighting fire in the heat of the day: An analysis of operational and environmental conditions of use for large airtankers in United States fire suppression

    Treesearch

    Crystal S. Stonesifer; Dave Calkin; Matthew P. Thompson; Keith D. Stockmann

    2016-01-01

    Large airtanker use is widespread in wildfire suppression in the United States. The current approach to nationally dispatching the fleet of federal contract airtankers relies on filling requests for airtankers to achieve suppression objectives identified by fire managers at the incident level. In general, demand is met if resources are available, and the...

  4. ARC-2008-ACD08-0147-023

    NASA Image and Video Library

    2008-07-14

    California Governor Arnold Schwarzenegger during a press briefing following a visit to Ames Earth Science Division for a briefing by Steve Hipskind on NASA Ames remote sensing fire fighting efforts. Also shown left to right, Mike Freilich, Director, NASA Earth Sceinces Division, Steve Hipskind, Pete Worden, Governor Schwarzenegger, Chief Del Walters, Assistant Region Fire Chief, California Department of Forestry and Fire Protection, Tom Maruyama, Deputy Director, Office of Emergency Services

  5. Preparation of sintered foam materials by alkali-activated coal fly ash.

    PubMed

    Zhao, Yelong; Ye, Junwei; Lu, Xiaobin; Liu, Mangang; Lin, Yuan; Gong, Weitao; Ning, Guiling

    2010-02-15

    Coal fly ash from coal fired power stations is a potential raw material for the production of ceramic tiles, bricks and blocks. Previous works have demonstrated that coal fly ash consists mainly of glassy spheres that are relatively resistant to reaction. An objective of this research was to investigate the effect of alkali on the preparation process of the foam material. Moreover, the influence of foam dosage on the water absorption, apparent density and compressive strength was evaluated. The experimental results showed that homogenous microstructures of interconnected pores could be obtained by adding 13 wt.% foaming agent at 1050 degrees C, leading to foams presenting water absorption, apparent density and compressive strength values of about 126.5%, 0.414 g/cm(3), 6.76 MPa, respectively.

  6. Acute health effects among firefighters exposed to a polyvinyl chloride (PVC) fire

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Markowitz, J.S.; Gutterman, E.M.; Schwartz, S.

    1989-05-01

    Firefighters are frequently being called on to fight fires that are chemical in nature. In the aftermath of a chemical fire in Plainfield, New Jersey on March 20-21, 1985, the authors conducted a retrospective cohort study which surveyed 80 firefighters exposed to burning polyvinyl chloride (PVC) as well as 15 nonexposed firefighter subjects. By means of an 81-item symptom checklist, exposed firefighters reported more frequent and severe symptoms at 5-6 weeks post incident. This was true for a total symptomatology score as well as 19 individual items. Some of the items with an elevated risk were consistent with exposure tomore » hydrogen chloride, the main pyrolysis product of polyvinyl chloride. Other items with an elevated risk appeared to be related to smoke inhalation while others seemed psychosocial in nature. Analyses conducted within the exposed firefighter group showed that fighting the fire the first day, being a truckman, and residence within 1 mile (1.6 km) of the firehouse were significant risk factors for high total symptom scores. These risk factors may have been associated with level or duration of exposure to the toxic substances produced during the fire.« less

  7. The Cleveland Aircraft Fire Tests

    NASA Technical Reports Server (NTRS)

    Brenneman, James J.; Heine, Donald A.

    1968-01-01

    On June 30 and July 1, 1966, tests were conducted to evaluate high expansion foam's ability to extend the time for which an aircraft passenger cabin environment would remain survivable during a post-crash fire. While some results tend to confirm those of similar tests, others may shed new light on the problem.

  8. Sodium Bentonite-Based Fire Retardant Coatings Containing Starch

    USDA-ARS?s Scientific Manuscript database

    Sodium bentonite (SB) gel and foam coatings were tested for their ability to suppress the rate of heat increase at the surface of commercial lap siding. Starch was added to some treatments to determine whether it stabilized the coating and prevented vertical slumping. A commercial fire protection ge...

  9. Cone calorimeter testing of foam core sandwich panels treated with intumescent paper underneath the veneer (FRV)

    Treesearch

    Mark A. Dietenberger; Ali Shalbafan; Johannes Welling

    2017-01-01

    Surfaces of novel foam core sandwich panels were adhered with intumescent fire‐retardant paper underneath the veneers (FRV) to improve their flammability properties. The panels were evaluated by means of cone calorimeter test (ASTM E 1354). Variables tested were different surface layer treatments, adhesives used for veneering, surface layer thicknesses, and processing...

  10. Release-rate calorimetry of multilayered materials for aircraft seats

    NASA Technical Reports Server (NTRS)

    Fewell, L. L.; Duskin, F. E.; Spieth, H.; Trabold, E.; Parker, J. A.

    1979-01-01

    Multilayered samples of contemporary and improved fire resistant aircraft seat materials (foam cushion, decorative fabric, slip sheet, fire blocking layer, and cushion reinforcement layer) were evaluated for their rates of heat release and smoke generation. Top layers (decorative fabric, slip sheet, fire blocking, and cushion reinforcement) with glass fiber block cushion were evaluated to determine which materials based on their minimum contributions to the total heat release of the multilayered assembly may be added or deleted. Top layers exhibiting desirable burning profiles were combined with foam cushion materials. The smoke and heat release rates of multilayered seat materials were then measured at heat fluxes of 1.5 and 3.5 W/sq cm. Choices of contact and silicone adhesives for bonding multilayered assemblies were based on flammability, burn and smoke generation, animal toxicity tests, and thermal gravimetric analysis. Abrasion tests were conducted on the decorative fabric covering and slip sheet to ascertain service life and compatibility of layers.

  11. Open cell fire-resistant foam

    NASA Technical Reports Server (NTRS)

    Thompson, J. E.; Wittman, J. W.; Reynard, K. A.

    1976-01-01

    Candidate polyphosphazene polymers were investigated to develop a fire-resistant, thermally stable and flexible open cell foam. The copolymers were prepared in several mole ratios of the substituent side chains and a (nominal) 40:60 derivative was selected for formulation studies. Synthesis of the polymers involved solution by polymerization of hexachlorophosphazene to soluble high molecular weight poly(dichlorophosphazene), followed by derivatization of the resultant polymer in a normal fashion to give polymers in high yield and high molecular weight. Small amounts of a cure site were incorporated into the polymer for vulcanization purposes. The poly(aryloxyphosphazenes) exhibited good thermal stability and the first polymer mentioned above exhibited the best thermal behavior of all the candidate polymers studied.

  12. 76 FR 17327 - 100th Anniversary of the Triangle Shirtwaist Factory Fire

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-29

    ... responsibility to provide a safe environment for all American workers. NOW, THEREFORE, I, BARACK OBAMA, President... since the Triangle factory fire, we are still fighting to provide adequate working conditions for all... collective bargaining as a tool to give workers a seat at the tables of power. Working Americans are the...

  13. US Research on Wildland Fires??…with a Focus on EPA’s Efforts

    EPA Science Inventory

    The United States spends more than $1 billion every year to fight wildfires. According to National Interagency Fire Center data, of the 10 years with the largest acreage burned, nine have occurred since 2000 (as of 2012). This period coincides with many of the warmest years on re...

  14. The potential for pulmonary heat injury resulting from the activation of a cabin water spray system to fight aircraft cabin fires.

    DOT National Transportation Integrated Search

    1995-05-01

    A cabin water spray system (CWSS) has been suggested as a means of attenuating the severity of smoke and fire commonly associated with aircraft accidents. All aspects of passenger and cabin safety must be considered when evaluating a new safety syste...

  15. Fight Fire with Fire

    ERIC Educational Resources Information Center

    Stroud, Sara

    2009-01-01

    When Megan Meier hanged herself in 2006 after being the brunt of a MySpace prank, followed by the subsequent trial of the adult who participated in the 13-year-old girl's harassment, cyberbullying took its place in the eye of a media storm. All the ensuing attention has translated into increased concern among parents and a heightened awareness…

  16. Fire Safety Aspects of Polymeric Materials. Volume 6. Aircraft. Civil and Military

    DTIC Science & Technology

    1977-01-01

    resistance of the existing Polyurethane foam- based seating sys- tems be improved through design, construction, and selection of covering materials. 12. A...aircraft interiors under real fire conditions. To provide the data base for developing improved fire safety standards for aircraft, four types of...the determination of immobilizing effect was based on performance in the swimming test, a simple exercise method also favored by Kimmerle to provide

  17. OCULUS fire: a command and control system for fire management with crowd sourcing and social media interconnectivity

    NASA Astrophysics Data System (ADS)

    Thomopoulos, Stelios C. A.; Kyriazanos, Dimitris M.; Astyakopoulos, Alkiviadis; Dimitros, Kostantinos; Margonis, Christos; Thanos, Giorgos Konstantinos; Skroumpelou, Katerina

    2016-05-01

    AF3 (Advanced Forest Fire Fighting2) is a European FP7 research project that intends to improve the efficiency of current fire-fighting operations and the protection of human lives, the environment and property by developing innovative technologies to ensure the integration between existing and new systems. To reach this objective, the AF3 project focuses on innovative active and passive countermeasures, early detection and monitoring, integrated crisis management and advanced public information channels. OCULUS Fire is the innovative control and command system developed within AF3 as a monitoring, GIS and Knowledge Extraction System and Visualization Tool. OCULUS Fire includes (a) an interface for real-time updating and reconstructing of maps to enable rerouting based on estimated hazards and risks, (b) processing of GIS dynamic re-construction and mission re-routing, based on the fusion of airborne, satellite, ground and ancillary geolocation data, (c) visualization components for the C2 monitoring system, displaying and managing information arriving from a variety of sources and (d) mission and situational awareness module for OCULUS Fire ground monitoring system being part of an Integrated Crisis Management Information System for ground and ancillary sensors. OCULUS Fire will also process and visualise information from public information channels, social media and also mobile applications by helpful citizens and volunteers. Social networking, community building and crowdsourcing features will enable a higher reliability and less false alarm rates when using such data in the context of safety and security applications.

  18. Monolithic catalyst beds for hydrazine reactors

    NASA Technical Reports Server (NTRS)

    1973-01-01

    A monolithic catalyst bed for monopropellant hydrazine decomposition was evaluated. The program involved the evaluation of a new hydrazine catalyst concept wherein open-celled foamed materials are used as supports for the active catalysts. A high-surface-area material is deposited upon the open-celled foamed material and is then coated with an active metal to provide a spontaneous catalyst. Only a fraction of the amount of expensive active metal in currently available catalysts is needed to promote monolithic catalyst. Numerous parameters were evaluated during the program, and the importance of additional parameters became obvious only while the program was in progress. A demonstration firing (using a 2.2-Newton (N)(0.5-lbf) reactor) successfully accumulated 7,700 seconds of firing time and 16 ambient temperature starts without degradation. Based on the excellent results obtained throughout the program and the demonstrated life capability of the monolithic foam, it is recommended that additional studies be conducted to further exploit the advantages of this concept.

  19. Bridging the divide between fire safety research and fighting fire safely: How do we convey research innovation to contribute more effectively to wildland firefighter safety?

    Treesearch

    Theodore Ted Adams; Bret W. Butler; Sara Brown; Vita Wright; Anne Black

    2017-01-01

    Creating a safe workplace for wildland firefighters has long been at the centre of discussion for researchers and practitioners. The goal of wildland fire safety research has been to protect operational firefighters, yet its contributions often fall short of potential because much is getting lost in the translation of peer-reviewed results to potential and intended...

  20. 75 FR 38007 - Airworthiness Directives; The Boeing Company Model 747-100, 747-100B, 747-100B SUD, 747-200B, 747...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-01

    ... the environmental control system (ECS). This AD results from reports of duct assemblies in the ECS... assemblies in the ECS wrapped with BMS 8-39 polyurethane foam insulation, a material of which the fire... igniting the BMS 8-39 polyurethane foam insulation on the duct assemblies of the ECS, which could propagate...

Top