Evaluation of silvicultural treatments and biomass use for reducing fire hazard in western states
Kenneth E. Skog; R. James Barbour; Karen L. Abt; E.M. (Ted) Bilek; Frank Burch; Roger D. Fight; Robert J. Hugget; Patrick D. Miles; Elizabeth D. Reinhardt; Wayne D. Shepperd
2006-01-01
Several analyses have shown that fire hazard is a concern for substantial areas of forestland, shrubland, grassland, and range in the western United States. In response, broadscale management strategies, such as the National Fire Plan, established actions to reduce the threat of undesirable fire. Available budgets are insufficient to pay for vegetative management on...
Injury risks of EMS responders: evidence from the National Fire Fighter Near-Miss Reporting System
Taylor, Jennifer A; Davis, Andrea L; Barnes, Brittany; Lacovara, Alicia V; Patel, Reema
2015-01-01
Objectives We analysed near-miss and injury events reported to the National Fire Fighter Near-Miss Reporting System (NFFNMRS) to investigate the workplace hazards and safety concerns of Emergency Medical Services (EMS) responders in the USA. Methods We reviewed 769 ‘non-fire emergency event’ reports from the NFFNMRS using a mixed methods approach. We identified 185 emergency medical calls and analysed their narrative text fields. We assigned Mechanism of Near-Miss/Injury and Nature of Injury codes and then tabulated frequencies (quantitative). We coded major themes regarding work hazards and safety concerns reported by the EMS responders (qualitative). Results Of the 185 emergency medical calls, the most commonly identified Mechanisms of Near-Miss/Injury to EMS responders was Assaults, followed by Struck-by Motor Vehicle, and Motor Vehicle Collision. The most commonly identified weapon used in an assault was a firearm. We identified 5 major domains of workplace hazards and safety concerns: Assaults by Patients, Risks from Motor Vehicles, Personal Protective Equipment, Relationships between Emergency Responders, and Policies, Procedures and Practices. Conclusions Narrative text from the NFFNMRS is a rich source of data that can be analysed quantitatively and qualitatively to provide insight into near-misses and injuries sustained by EMS responders. Near-miss reporting systems are critical components for occupational hazard surveillance. PMID:26068510
Crundall, David; Kroll, Victoria
2018-05-18
Can hazard perception testing be useful for the emergency services? Previous research has found emergency response drivers' (ERDs) to perform better than controls, however these studies used clips of normal driving. In contrast, the current study filmed footage from a fire-appliance on blue-light training runs through Nottinghamshire, and endeavoured to discriminate between different groups of EDRs based on experience and collision risk. Thirty clips were selected to create two variants of the hazard perception test: a traditional push-button test requiring speeded-responses to hazards, and a prediction test that occludes at hazard onset and provides four possible outcomes for participants to choose between. Three groups of fire-appliance drivers (novices, low-risk experienced and high-risk experienced), and age-matched controls undertook both tests. The hazard perception test only discriminated between controls and all FA drivers, whereas the hazard prediction test was more sensitive, discriminating between high and low-risk experienced fire appliance drivers. Eye movement analyses suggest that the low-risk drivers were better at prioritising the hazardous precursors, leading to better predictive accuracy. These results pave the way for future assessment and training tools to supplement emergency response driver training, while supporting the growing literature that identifies hazard prediction as a more robust measure of driver safety than traditional hazard perception tests. Copyright © 2018 Elsevier Ltd. All rights reserved.
Focus on...The right tools: Managing for fire using FIA inventory data.
USDA Forest Service
2003-01-01
The relative severity of recent fire seasons has led to numerous debates about the health, associated fire hazards, and effectiveness of fuel reduction treatments in forests across the United States. Scientific analyses of forest inventories offer policy makers and other interested parties objective information with which to make crucial forest management decisions....
NASA Astrophysics Data System (ADS)
Jalilzadeh Shadlouei, A.; Delavar, M. R.
2013-09-01
There are many vegetation in Iran. This is because of extent of Iran and its width. One of these vegetation is forest vegetation most prevalent in Northern provinces named Guilan, Mazandaran, Gulestan, Ardebil as well as East Azerbaijan. These forests are always threatened by natural forest fires so much so that there have been reports of tens of fires in recent years. Forest fires are one of the major environmental as well as economic, social and security concerns in the world causing much damages. According to climatology, forest fires are one of the important factors in the formation and dispersion of vegetation. Also, regarding the environment, forest fires cause the emission of considerable amounts of greenhouse gases, smoke and dust into the atmosphere which in turn causes the earth temperature to rise up and are unhealthy to humans, animals and vegetation. In agriculture droughts are the usual side effects of these fires. The causes of forest fires could be categorized as either Human or Natural Causes. Naturally, it is impossible to completely contain forest fires; however, areas with high potentials of fire could be designated and analysed to decrease the risk of fires. The zoning of forest fire potential is a multi-criteria problem always accompanied by inherent uncertainty like other multi-criteria problems. So far, various methods and algorithm for zoning hazardous areas via Remote Sensing (RS) and Geospatial Information System (GIS) have been offered. This paper aims at zoning forest fire potential of Gulestan Province of Iran forests utilizing Remote Sensing, Geospatial Information System, meteorological data, MODIS images and granular computing method. Granular computing is part of granular mathematical and one way of solving multi-criteria problems such forest fire potential zoning supervised by one expert or some experts , and it offers rules for classification with the least inconsistencies. On the basis of the experts' opinion, 6 determinative criterias contributing to forest fires have been designated as follows: vegetation (NDVI), slope, aspect, temperature, humidity and proximity to roadways. By applying these variables on several tentatively selected areas and formation information tables and producing granular decision tree and extraction of rules, the zoning rules (for the areas in question) were extracted. According to them the zoning of the entire area has been conducted. The zoned areas have been classified into 5 categories: high hazard, medium hazard (high), medium hazard (low), low hazard (high), low hazard (low). According to the map, the zoning of most of the areas fall into the low hazard (high) class while the least number of areas have been classified as low hazard (low). Comparing the forest fires in these regions in 2010 with the MODIS data base for forest fires, it is concluded that areas with high hazards of forest fire have been classified with a 64 percent precision. In other word 64 percent of pixels that are in high hazard classification are classified according to MODIS data base. Using this method we obtain a good range of Perception. Manager will reduce forest fire concern using precautionary proceeding on hazardous area.
Oxygen Compatibility Assessment of Components and Systems
NASA Technical Reports Server (NTRS)
Stoltzfus, Joel; Sparks, Kyle
2010-01-01
Fire hazards are inherent in oxygen systems and a storied history of fires in rocket engine propulsion components exists. To detect and mitigate these fire hazards requires careful, detailed, and thorough analyses applied during the design process. The oxygen compatibility assessment (OCA) process designed by NASA Johnson Space Center (JSC) White Sands Test Facility (WSTF) can be used to determine the presence of fire hazards in oxygen systems and the likelihood of a fire. This process may be used as both a design guide and during the approval process to ensure proper design features and material selection. The procedure for performing an OCA is a structured step-by-step process to determine the most severe operating conditions; assess the flammability of the system materials at the use conditions; evaluate the presence and efficacy of ignition mechanisms; assess the potential for a fire to breach the system; and determine the reaction effect (the potential loss of life, mission, and system functionality as the result of a fire). This process should be performed for each component in a system. The results of each component assessment, and the overall system assessment, should be recorded in a report that can be used in the short term to communicate hazards and their mitigation and to aid in system/component development and, in the long term, to solve anomalies that occur during engine testing and operation.
Guide for Oxygen Compatibility Assessments on Oxygen Components and Systems
NASA Technical Reports Server (NTRS)
Rosales, Keisa R.; Shoffstall, Michael S.; Stoltzfus, Joel M.
2007-01-01
Understanding and preventing fire hazards is necessary when designing, maintaining, and operating oxygen systems. Ignition risks can be minimized by controlling heat sources and using materials that will not ignite or will not support burning in the end-use environment. Because certain materials are more susceptible to ignition in oxygen-enriched environments, a compatibility assessment should be performed before the component is introduced into an oxygen system. This document provides an overview of oxygen fire hazards and procedures that are consistent with the latest versions of American Society for Testing and Materials (ASTM) Standards G63 (1999) and G94 (2005) to address fire hazards associated with oxygen systems. This document supersedes the previous edition, NASA Technical Memorandum 104823, Guide for Oxygen Hazards Analyses on Components and Systems (1996). The step-by-step oxygen compatibility assessment method described herein (see Section 4) enables oxygen-system designers, system engineers, and facility managers to determine areas of concern with respect to oxygen compatibility and, ultimately, prevent damage to a system or injury to personnel.
Robert E. Keane; Stacy A. Drury; Eva C. Karau; Paul F. Hessburg; Keith M. Reynolds
2010-01-01
This paper presents modeling methods for mapping fire hazard and fire risk using a research model called FIREHARM (FIRE Hazard and Risk Model) that computes common measures of fire behavior, fire danger, and fire effects to spatially portray fire hazard over space. FIREHARM can compute a measure of risk associated with the distribution of these measures over time using...
Linear Aerospike SR-71 Experiment (LASRE): Aerospace Propulsion Hazard Mitigation Systems
NASA Technical Reports Server (NTRS)
Mizukami, Masashi; Corpening, Griffin P.; Ray, Ronald J.; Hass, Neal; Ennix, Kimberly A.; Lazaroff, Scott M.
1998-01-01
A major hazard posed by the propulsion system of hypersonic and space vehicles is the possibility of fire or explosion in the vehicle environment. The hazard is mitigated by minimizing or detecting, in the vehicle environment, the three ingredients essential to producing fire: fuel, oxidizer, and an ignition source. The Linear Aerospike SR-71 Experiment (LASRE) consisted of a linear aerospike rocket engine integrated into one-half of an X-33-like lifting body shape, carried on top of an SR-71 aircraft. Gaseous hydrogen and liquid oxygen were used as propellants. Although LASRE is a one-of-a-kind experimental system, it must be rated for piloted flight, so this test presented a unique challenge. To help meet safety requirements, the following propulsion hazard mitigation systems were incorporated into the experiment: pod inert purge, oxygen sensors, a hydrogen leak detection algorithm, hydrogen sensors, fire detection and pod temperature thermocouples, water misting, and control room displays. These systems are described, and their development discussed. Analyses, ground test, and flight test results are presented, as are findings and lessons learned.
Use of financial and economic analyses by federal forest managers for woody biomass removal
Todd A. Morgan; Jason P. Brandt; John D. Baldridge; Dan R. Loeffler
2011-01-01
This study was sponsored by the Joint Fire Science Program to understand and enhance the ability of federal land managers to address financial and economic (F&E) aspects of woody biomass removal as a component of fire hazard reduction. Focus groups were conducted with nearly 100 federal land managers throughout the western United States. Several issues and...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Romander, C.M.
The potential hazard of HCDA-generated missiles is analyzed, and the current status of the potential hazards of sodium fires is summarized. Simple analyses are performed to determine lower bounds on the HCDA energetics required to generate missiles that could reach the secondary containment structure of a 1000-MWe LMFBR. The potential missiles considered include the vessel head, components mounted on the head, and conrol rods.
46 CFR 71.25-45 - Fire hazards.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 3 2010-10-01 2010-10-01 false Fire hazards. 71.25-45 Section 71.25-45 Shipping COAST... Inspection § 71.25-45 Fire hazards. (a) At each annual inspection, the inspector shall examine the tank tons... fire hazard. (b) [Reserved] ...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-14
... Regarding Fire Hazard Reduction Programs in the Wildland-Urban Interface AGENCY: Forest Service, USDA... Regarding Fire Hazard Reduction Programs in the Wildland-Urban Interface. DATES: Comments must be received... holidays. SUPPLEMENTARY INFORMATION: Title: Understanding Value Trade-offs Regarding Fire Hazard Reduction...
Rocky Mountain Research Station USDA Forest Service
2004-01-01
Fire hazard reflects the potential fire behavior and magnitude of effects as a function of fuel conditions. This fact sheet discusses crown fuels, surface fuels, and ground fuels and their contribution and involvement in wildland fire.Other publications in this series...
Climate change and wildland firefighter health and safety.
Withen, Patrick
2015-02-01
The author examines how climate change is impacting wildland firefighters. Climate change has made wildland fires more frequent and more intense. The increase in frequency and intensity of fires has pushed the number of fatalities and injuries higher in recent decades. The most common hazards on fires follow the trend of fire in general in that these hazards become more frequent and intense. Burnovers, heat exhaustion, tree hazards, and many other common fire hazards are more likely. The fire suppression agencies are making every effort to improve health and safety on fires by improving communication, weather forecasting, mapping, fire shelters, decision making and more. Despite these efforts, wildfires are becoming ever more hazardous because of climate change and the increasing frequency and intensity of wildfires. © 2015 SAGE Publications.
46 CFR 91.25-45 - Fire hazards.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Fire hazards. 91.25-45 Section 91.25-45 Shipping COAST... CERTIFICATION Inspection for Certification § 91.25-45 Fire hazards. (a) At each inspection for certification and... that there is no accumulation of oil which might create a fire hazard. [CGFR 65-50, 30 FR 16974, Dec...
46 CFR 189.25-45 - Fire hazards.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Fire hazards. 189.25-45 Section 189.25-45 Shipping COAST... CERTIFICATION Inspection for Certification § 189.25-45 Fire hazards. At each inspection for certification and... that there is no accumulation of oil which might create a fire hazard. [CGFR 67-83, 33 FR 1118, Jan. 27...
46 CFR 190.05-3 - Fire hazards to be minimized.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS CONSTRUCTION AND ARRANGEMENT General Fire Protection § 190.05-3 Fire hazards to be minimized. (a) The general construction of the vessel shall be such as to minimize fire hazards. ...
Ghermandi, Luciana; Beletzky, Natacha A; de Torres Curth, Mónica I; Oddi, Facundo J
2016-12-01
The overlapping zone between urbanization and wildland vegetation, known as the wildland urban interface (WUI), is often at high risk of wildfire. Human activities increase the likelihood of wildfires, which can have disastrous consequences for property and land use, and can pose a serious threat to lives. Fire hazard assessments depend strongly on the spatial scale of analysis. We assessed the fire hazard in a WUI area of a Patagonian city by working at three scales: landscape, community and species. Fire is a complex phenomenon, so we used a large number of variables that correlate a priori with the fire hazard. Consequently, we analyzed environmental variables together with fuel load and leaf flammability variables and integrated all the information in a fire hazard map with four fire hazard categories. The Nothofagus dombeyi forest had the highest fire hazard while grasslands had the lowest. Our work highlights the vulnerability of the wildland-urban interface to fire in this region and our suggested methodology could be applied in other wildland-urban interface areas. Particularly in high hazard areas, our work could help in spatial delimitation policies, urban planning and development of plans for the protection of human lives and assets. Copyright © 2016 Elsevier Ltd. All rights reserved.
van Mantgem, Phillip J.; Lalemand, Laura; Keifer, MaryBeth; Kane, Jeffrey M.
2016-01-01
Prescribed fire is a widely used forest management tool, yet the long-term effectiveness of prescribed fire in reducing fuels and fire hazards in many vegetation types is not well documented. We assessed the magnitude and duration of reductions in surface fuels and modeled fire hazards in coniferous forests across nine U.S. national parks in California and the Colorado Plateau. We used observations from a prescribed fire effects monitoring program that feature standard forest and surface fuels inventories conducted pre-fire, immediately following an initial (first-entry) prescribed fire and at varying intervals up to >20 years post-fire. A subset of these plots was subjected to prescribed fire again (second-entry) with continued monitoring. Prescribed fire effects were highly variable among plots, but we found on average first-entry fires resulted in a significant post-fire reduction in surface fuels, with litter and duff fuels not returning to pre-fire levels over the length of our observations. Fine and coarse woody fuels often took a decade or longer to return to pre-fire levels. For second-entry fires we found continued fuels reductions, without strong evidence of fuel loads returning to levels observed immediately prior to second-entry fire. Following both first- and second-entry fire there were increases in estimated canopy base heights, along with reductions in estimated canopy bulk density and modeled flame lengths. We did not find evidence of return to pre-fire conditions during our observation intervals for these measures of fire hazard. Our results show that prescribed fire can be a valuable tool to reduce fire hazards and, depending on forest conditions and the measurement used, reductions in fire hazard can last for decades. Second-entry prescribed fire appeared to reinforce the reduction in fuels and fire hazard from first-entry fires.
Rocky Mountain Research Station USDA Forest Service
2004-01-01
Many managers and policymakers guided by the National Environmental Policy Act process want to understand the scientific principles on which they can base fuel treatments for reducing the size and severity of wildfires. These Forest Structure and Fire Hazard fact sheets discuss how to estimate fire hazard, how to visualize fuel treatments, and how the role of...
24 CFR 200.86 - Covenant for fire and other hazard insurance.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Covenant for fire and other hazard insurance. The mortgage shall contain a covenant binding the mortgagor to maintain fire and extended coverage insurance on the property in accordance with terms and... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Covenant for fire and other hazard...
32 CFR 935.161 - Fire hazards.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 32 National Defense 6 2011-07-01 2011-07-01 false Fire hazards. 935.161 Section 935.161 National... WAKE ISLAND CODE Public Safety § 935.161 Fire hazards. (a) Each person engaged in a business or other activity on Wake Island shall, at his expense, provide and maintain (in an accessible location) fire...
32 CFR 935.161 - Fire hazards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 32 National Defense 6 2010-07-01 2010-07-01 false Fire hazards. 935.161 Section 935.161 National... WAKE ISLAND CODE Public Safety § 935.161 Fire hazards. (a) Each person engaged in a business or other activity on Wake Island shall, at his expense, provide and maintain (in an accessible location) fire...
32 CFR 935.161 - Fire hazards.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 32 National Defense 6 2014-07-01 2014-07-01 false Fire hazards. 935.161 Section 935.161 National... WAKE ISLAND CODE Public Safety § 935.161 Fire hazards. (a) Each person engaged in a business or other activity on Wake Island shall, at his expense, provide and maintain (in an accessible location) fire...
32 CFR 935.161 - Fire hazards.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 32 National Defense 6 2012-07-01 2012-07-01 false Fire hazards. 935.161 Section 935.161 National... WAKE ISLAND CODE Public Safety § 935.161 Fire hazards. (a) Each person engaged in a business or other activity on Wake Island shall, at his expense, provide and maintain (in an accessible location) fire...
32 CFR 935.161 - Fire hazards.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 32 National Defense 6 2013-07-01 2013-07-01 false Fire hazards. 935.161 Section 935.161 National... WAKE ISLAND CODE Public Safety § 935.161 Fire hazards. (a) Each person engaged in a business or other activity on Wake Island shall, at his expense, provide and maintain (in an accessible location) fire...
Fire hazard after prescribed burning in a gorse shrubland: implications for fuel management.
Marino, Eva; Guijarro, Mercedes; Hernando, Carmen; Madrigal, Javier; Díez, Carmen
2011-03-01
Prescribed burning is commonly used to prevent accumulation of biomass in fire-prone shrubland in NW Spain. However, there is a lack of knowledge about the efficacy of the technique in reducing fire hazard in these ecosystems. Fire hazard in burned shrubland areas will depend on the initial capacity of woody vegetation to recover and on the fine ground fuels existing after fire. To explore the effect that time since burning has on fire hazard, experimental tests were performed with two fuel complexes (fine ground fuels and regenerated shrubs) resulting from previous prescribed burnings conducted in a gorse shrubland (Ulex europaeus L.) one, three and five years earlier. A point-ignition source was used in burning experiments to assess ignition and initial propagation success separately for each fuel complex. The effect of wind speed was also studied for shrub fuels, and several flammability parameters were measured. Results showed that both ignition and initial propagation success of fine ground fuels mainly depended on fuel depth and were independent of time since burning, although flammability parameters indicated higher fire hazard three years after burning. In contrast, time since burning increased ignition and initial propagation success of regenerated shrub fuels, as well as the flammability parameters assessed, but wind speed had no significant effect. The combination of results of fire hazard for fine ground fuels and regenerated shrubs according to the variation in relative coverage of each fuel type after prescribed burning enabled an assessment of integrated fire hazard in treated areas. The present results suggest that prescribed burning is a very effective technique to reduce fire hazard in the study area, but that fire hazard will be significantly increased by the third year after burning. These results are valuable for fire prevention and fuel management planning in gorse shrubland areas. Copyright © 2010 Elsevier Ltd. All rights reserved.
Southwestern Oregon's Biscuit Fire: An Analysis of Forest Resources, Fire Severity, and Fire Hazard
David L. Azuma; Glenn A. Christensen
2005-01-01
This study compares pre-fire field inventory data (collected from 1993 to 1997) in relation to post-fire mapped fire severity classes and the Fire and Fuels Extension of the Forest Vegetation Simulator growth and yield model measures of fire hazard for the portion of the Siskiyou National Forest in the 2002 Biscuit fire perimeter of southwestern Oregon. Post-fire...
Carl E. Fiedler; Charles E. Keegan; Christopher W. Woodall; Todd A. Morgan
2004-01-01
Estimates of crown fire hazard are presented for existing forest conditions in Montana by density class, structural class, forest type, and landownership. Three hazard reduction treatments were evaluated for their effectiveness in treating historically fire-adapted forests (ponderosa pine (Pinus ponderosa Dougl. ex Laws.), Douglas-fir (...
Reduction of Fire Hazard in Materials for Irrigators and Water Collectors in Cooling Towers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smirnov, N. V.; Konstantinova, N. I., E-mail: konstantinova-n@inbox.ru; Gordon, E. P.
A way of reducing the fire hazard of PVC film used to make cooling-tower irrigators and water collectors is examined. A new generation of fire retardant, nanostructured magnesium hydroxide, is used to impart fire retardant properties. The fabrication technology is optimized with a roller-calendering manufacturing technique, and the permissible ranges of fire hazard indicators for materials in irrigators and water collectors are determined.
Fire fighting aboard ships. Volume 1: Hazard analysis and behavior of combustible materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stavitskiy, M.G.; Kortunov, M.F.; Sidoryuk, V.M.
1983-01-01
The volume zeros in on fire hazards on ships afloat or under construction/repair. It examines fire hazards peculiar to ships carrying particular cargoes, such as dry-cargo ships, tankers, and factory and fishing vessels. This volume examines specific features of fire-fighting equipment, along with the thermal behavior of materials used in shipbuilding.
NASA Technical Reports Server (NTRS)
Colwell, R. N.
1973-01-01
The identification of fire hazards at the San Pablo Reservoir Test Site in California using ERTS-1 data is discussed. It is stated that the two primary fire hazards in the area are caused by wild oat plants and eucalyptus trees. The types of imagery used in conducting the study are reported. Aerial photographs of specific areas are included to show the extent of the fire hazards.
Reducing fire hazard: balancing costs and outcomes.
Valerie Rapp
2004-01-01
Massive wildfires in recent years have given urgency to questions of how to reduce fire hazard in Western forests, how to finance the work, and how to use the wood, especially in forests crowded with small trees. Scientists have already developed tools that estimate fire hazard in a forest stand. But hazard is more difficult to estimate at a landscape scale, involving...
Assessing crown fire potential by linking models of surface and crown fire behavior
Joe H. Scott; Elizabeth D. Reinhardt
2001-01-01
Fire managers are increasingly concerned about the threat of crown fires, yet only now are quantitative methods for assessing crown fire hazard being developed. Links among existing mathematical models of fire behavior are used to develop two indices of crown fire hazard-the Torching Index and Crowning Index. These indices can be used to ordinate different forest...
Decreasing Fires in Mediterranean Europe
Turco, Marco; Bedia, Joaquín; Di Liberto, Fabrizio; Fiorucci, Paolo; von Hardenberg, Jost; Koutsias, Nikos; Llasat, Maria-Carmen; Xystrakis, Fotios; Provenzale, Antonello
2016-01-01
Forest fires are a serious environmental hazard in southern Europe. Quantitative assessment of recent trends in fire statistics is important for assessing the possible shifts induced by climate and other environmental/socioeconomic changes in this area. Here we analyse recent fire trends in Portugal, Spain, southern France, Italy and Greece, building on a homogenized fire database integrating official fire statistics provided by several national/EU agencies. During the period 1985-2011, the total annual burned area (BA) displayed a general decreasing trend, with the exception of Portugal, where a heterogeneous signal was found. Considering all countries globally, we found that BA decreased by about 3020 km2 over the 27-year-long study period (i.e. about -66% of the mean historical value). These results are consistent with those obtained on longer time scales when data were available, also yielding predominantly negative trends in Spain and France (1974-2011) and a mixed trend in Portugal (1980-2011). Similar overall results were found for the annual number of fires (NF), which globally decreased by about 12600 in the study period (about -59%), except for Spain where, excluding the provinces along the Mediterranean coast, an upward trend was found for the longer period. We argue that the negative trends can be explained, at least in part, by an increased effort in fire management and prevention after the big fires of the 1980’s, while positive trends may be related to recent socioeconomic transformations leading to more hazardous landscape configurations, as well as to the observed warming of recent decades. We stress the importance of fire data homogenization prior to analysis, in order to alleviate spurious effects associated with non-stationarities in the data due to temporal variations in fire detection efforts. PMID:26982584
Decreasing Fires in Mediterranean Europe.
Turco, Marco; Bedia, Joaquín; Di Liberto, Fabrizio; Fiorucci, Paolo; von Hardenberg, Jost; Koutsias, Nikos; Llasat, Maria-Carmen; Xystrakis, Fotios; Provenzale, Antonello
2016-01-01
Forest fires are a serious environmental hazard in southern Europe. Quantitative assessment of recent trends in fire statistics is important for assessing the possible shifts induced by climate and other environmental/socioeconomic changes in this area. Here we analyse recent fire trends in Portugal, Spain, southern France, Italy and Greece, building on a homogenized fire database integrating official fire statistics provided by several national/EU agencies. During the period 1985-2011, the total annual burned area (BA) displayed a general decreasing trend, with the exception of Portugal, where a heterogeneous signal was found. Considering all countries globally, we found that BA decreased by about 3020 km2 over the 27-year-long study period (i.e. about -66% of the mean historical value). These results are consistent with those obtained on longer time scales when data were available, also yielding predominantly negative trends in Spain and France (1974-2011) and a mixed trend in Portugal (1980-2011). Similar overall results were found for the annual number of fires (NF), which globally decreased by about 12600 in the study period (about -59%), except for Spain where, excluding the provinces along the Mediterranean coast, an upward trend was found for the longer period. We argue that the negative trends can be explained, at least in part, by an increased effort in fire management and prevention after the big fires of the 1980's, while positive trends may be related to recent socioeconomic transformations leading to more hazardous landscape configurations, as well as to the observed warming of recent decades. We stress the importance of fire data homogenization prior to analysis, in order to alleviate spurious effects associated with non-stationarities in the data due to temporal variations in fire detection efforts.
78 FR 28892 - Hazardous Fire Risk Reduction, East Bay Hills, CA
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-16
... DEPARTMENT OF HOMELAND SECURITY Federal Emergency Management Agency [Docket ID FEMA 2010-0037] Hazardous Fire Risk Reduction, East Bay Hills, CA AGENCY: Federal Emergency Management Agency, DHS. ACTION..., limbing and mowing, thinning, and grazing techniques as appropriate to reduce the risk of fire hazard...
Modeling firebrand transport in wildfires using HIGRAD/FIRETEC
Eunmo Koo; Rodman R. Linn; Patrick J. Pagni; Carleton B. Edminster
2012-01-01
Firebrand transport is studied for disc and cylindrical firebrands by modelling their trajectories with a coupled-physics fire model, HIGRAD/FIRETEC. Through HIGRAD/FIRETEC simulations, the size of possible firebrands and travelled distances are analysed to assess spot ignition hazard. Trajectories modelled with and without the assumption that the firebrands'...
Potential Operating Room Fire Hazard of Bone Cement.
Sibia, Udai S; Connors, Kevin; Dyckman, Sarah; Zahiri, Hamid R; George, Ivan; Park, Adrian E; MacDonald, James H
Approximately 600 cases of operating room (OR) fires are reported annually. Despite extensive fire safety education and training, complete elimination of OR fires still has not been achieved. Each fire requires an ignition source, a fuel source, and an oxidizer. In this case report, we describe the potential fire hazard of bone cement in the OR. A total knee arthroplasty was performed with a standard medial parapatellar arthrotomy. Tourniquet control was used. After bone cement was applied to the prepared tibial surface, the surgeon used an electrocautery device to resect residual lateral meniscus tissue-and started a fire in the operative field. The surgeon suffocated the fire with a dry towel and prevented injury to the patient. We performed a PubMed search with a cross-reference search for relevant papers and found no case reports outlining bone cement as a potential fire hazard in the OR. To our knowledge, this is the first case report identifying bone cement as a fire hazard. OR fires related to bone cement can be eliminated by correctly assessing the setting time of the cement and avoiding application sites during electrocautery.
Fires in storages of LFO: Analysis of hazard of structural collapse of steel-aluminium containers.
Rebec, A; Kolšek, J; Plešec, P
2016-04-05
Pool fires of light fuel oil (LFO) in above-ground storages with steel-aluminium containers are discussed. A model is developed for assessments of risks of between-tank fire spread. Radiative effects of the flame body are accounted for by a solid flame radiation model. Thermal profiles evolved due to fire in the adjacent tanks and their consequential structural response is pursued in an exact (materially and geometrically non-linear) manner. The model's derivation is demonstrated on the LFO tank storage located near the Port of Koper (Slovenia). In support of the model, data from literature are adopted where appropriate. Analytical expressions are derived correspondingly for calculations of emissive characteristics of LFO pool fires. Additional data are collected from experiments. Fire experiments conducted on 300cm diameter LFO pans and at different wind speeds and high-temperature uniaxial tension tests of the analysed aluminium alloys types 3xxx and 6xxx are presented. The model is of an immediate fire engineering practical value (risk analyses) or can be used for further research purposes (e.g. sensitivity and parametric studies). The latter use is demonstrated in the final part of the paper discussing possible effects of high-temperature creep of 3xxx aluminium. Copyright © 2015 Elsevier B.V. All rights reserved.
Firefighter safety and photovoltaic installations research project
NASA Astrophysics Data System (ADS)
Backstrom, Robert; Dini, Dave
2012-10-01
Under the United States Department of Homeland Security (DHS) Assistance to Fire Fighters grant, UL LLC examined fire service concerns of photovoltaic (PV) systems. These concerns included firefighter vulnerability to electrical and casualty hazards when mitigating a fire involving photovoltaic (PV) modules systems. Findings include: 1. The electric shock hazard due to application of water is dependent on voltage, water conductivity, distance and spray pattern of the suppression stream. 2. Outdoor weather exposure rated electrical enclosures are not resistant to water penetration by fire hose streams. 3. Firefighter's gloves and boots afford limited protection against electrical shock provided the insulating surface is intact and dry. 4. "Turning off" an array is not a simple matter of opening a disconnect switch. 5. Tarps offer varying degrees of effectiveness. 6. Fire equipment scene lighting and exposure fires may illuminate PV systems sufficiently to cause a lock-on hazard. 7. Severely damaged PV arrays are capable of producing hazardous conditions. 8. Damage to modules from tools may result in both electrical and fire hazards. 9. Severing of conductors in both metal and plastic conduit results in electrical and fire hazards. 10. Responding personnel must stay away from the roofline in the event of modules or sections of an array sliding off the roof. 11. Fires under an array but above the roof may breach roofing materials and decking allowing fire to propagate into the attic space. Several tactical considerations were developed utilizing the data from the experiments.
ERIC Educational Resources Information Center
Texas State Commission on Fire Protection, Austin.
This booklet comprises the eighth grade component of a series of curriculum guides on fire and burn prevention. Designed to meet the age-specific needs of eighth grade students, its objectives include: (1) focusing on technical aspects of fire hazards and detection, and (2) exploring fire hazards outside the home. Texas essential elements of…
Evaluation of fire hazard inspection procedures in Butte County, California
William S. Folkman
1967-01-01
To assess effectiveness of fire hazard inspection procedures in securing compliance with fire safety requirements, effects of different types and combinations of contacts and timing were determined, and the production capacity of inspectors measured. It was demonstrated that fire law inspection is as much fire prevention education and engineering as it is law...
An evaluation of the relative fire hazards of jet A and jet B for commercial flight
NASA Technical Reports Server (NTRS)
Hibbard, R. R.; Hacker, P. T.
1973-01-01
The relative fire hazards of Jet A and Jet B aircraft fuels are evaluated. The evaluation is based on a consideration of the presence of and/or the generation of flammable mixtures in fuel systems, the ignition characteristics, and the flame propagation rates for the two fuel types. Three distinct aircraft operating regimes where fuel type may be a factor in fire hazards are considered. These are: (1) ground handling and refueling, (2) flight, and (3) crash. The evaluation indicates that the overall fire hazards for Jet A are less than for Jet B fuel.
Zhang, Taolin; Zhou, Xiaodong; Yang, Lizhong
2016-03-05
This work investigated experimentally and theoretically the fire hazards of thermal-insulation materials used in diesel locomotives under different radiation heat fluxes. Based on the experimental results, the critical heat flux for ignition was determined to be 6.15 kW/m² and 16.39 kW/m² for pure polyurethane and aluminum-polyurethane respectively. A theoretical model was established for both to predict the fire behaviors under different circumstances. The fire behavior of the materials was evaluated based on the flashover and the total heat release rate (HRR). The fire hazards levels were classified based on different experimental results. It was found that the fire resistance performance of aluminum-polyurethane is much better than that of pure-polyurethane under various external heat fluxes. The concentration of toxic pyrolysis volatiles generated from aluminum-polyurethane materials is much higher than that of pure polyurethane materials, especially when the heat flux is below 50 kW/m². The hazard index HI during peak width time was proposed based on the comprehensive impact of time and concentrations. The predicted HI in this model coincides with the existed N-gas and FED models which are generally used to evaluate the fire gas hazard in previous researches. The integrated model named HNF was proposed as well to estimate the fire hazards of materials by interpolation and weighted average calculation.
Zhang, Taolin; Zhou, Xiaodong; Yang, Lizhong
2016-01-01
This work investigated experimentally and theoretically the fire hazards of thermal-insulation materials used in diesel locomotives under different radiation heat fluxes. Based on the experimental results, the critical heat flux for ignition was determined to be 6.15 kW/m2 and 16.39 kW/m2 for pure polyurethane and aluminum-polyurethane respectively. A theoretical model was established for both to predict the fire behaviors under different circumstances. The fire behavior of the materials was evaluated based on the flashover and the total heat release rate (HRR). The fire hazards levels were classified based on different experimental results. It was found that the fire resistance performance of aluminum-polyurethane is much better than that of pure-polyurethane under various external heat fluxes. The concentration of toxic pyrolysis volatiles generated from aluminum-polyurethane materials is much higher than that of pure polyurethane materials, especially when the heat flux is below 50 kW/m2. The hazard index HI during peak width time was proposed based on the comprehensive impact of time and concentrations. The predicted HI in this model coincides with the existed N-gas and FED models which are generally used to evaluate the fire gas hazard in previous researches. The integrated model named HNF was proposed as well to estimate the fire hazards of materials by interpolation and weighted average calculation. PMID:28773295
Butt rot defect and potential hazard in lodgepole pine on selected California recreational areas
Lee A. Paine
1966-01-01
Within the area sampled, potentially hazardous lodgepole pine were common on recreational sites. The incidence of decayed and mechanically weak trees was correlated with fire damage. Two-thirds of fire-scarred trees were decayed; one-third were rated potentially hazardous. Fire scars occurred roughly in proportion to level of plot recreational use.
Risk analysis procedure for post-wildfire natural hazards in British Columbia
NASA Astrophysics Data System (ADS)
Jordan, Peter
2010-05-01
Following a severe wildfire season in 2003, and several subsequent damaging debris flow and flood events, the British Columbia Forest Service developed a procedure for analysing risks to public safety and infrastructure from such events. At the same time, the Forest Service undertook a research program to determine the extent of post-wildfire hazards, and examine the hydrologic and geomorphic processes contributing to the hazards. The risk analysis procedure follows the Canadian Standards Association decision-making framework for risk management (which in turn is based on international standards). This has several steps: identification of risk, risk analysis and estimation, evaluation of risk tolerability, developing control or mitigation strategies, and acting on these strategies. The Forest Service procedure deals only with the first two steps. The results are passed on to authorities such as the Provincial Emergency Program and local government, who are responsible for evaluating risks, warning residents, and applying mitigation strategies if appropriate. The objective of the procedure is to identify and analyse risks to public safety and infrastructure. The procedure is loosely based on the BAER (burned area emergency response) program in the USA, with some important differences. Our procedure focuses on identifying risks and warning affected parties, not on mitigation activities such as broadcast erosion control measures. Partly this is due to limited staff and financial resources. Also, our procedure is not multi-agency, but is limited to wildfires on provincial forest land; in British Columbia about 95% of forest land is in the publicly-owned provincial forest. Each fire season, wildfires are screened by size and proximity to values at risk such as populated areas. For selected fires, when the fire is largely contained, the procedure begins with an aerial reconnaissance of the fire, and photography with a hand-held camera, which can be used to make a preliminary map of vegetation burn severity if desired. The next steps include mapping catchment boundaries, field traverses to collect data on soil burn severity and water repellency, identification of unstable hillslopes and channels, and inspection of values at risk from hazards such as debris flows or flooding. BARC (burned area reflectance classification) maps based on satellite imagery are prepared for some fires, although these are typically not available for several weeks. Our objective is to make a preliminary risk analysis report available about two weeks after the fire is contained. If high risks to public safety or infrastructure are identified, the risk analysis reports may make recommendations for mitigation measures to be considered; however, acting on these recommendations is the responsibility of local land managers, local government, or landowners. Mitigation measures for some fires have included engineering treatments to reduce the hydrologic impact of logging roads, protective structures such as dykes or berms, and straw mulching to reduce runoff and erosion on severely burned areas. The Terrace Mountain Fire, with burned 9000 hectares in the Okanagan Valley in 2009, is used as an example of the application of the procedure.
Emergency Response Capability Baseline Needs Assessment - Compliance Assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sharry, John A.
This document was prepared by John A. Sharry, LLNL Fire Marshal and Division Leader for Fire Protection and was reviewed by LLNL Emergency Management Department Head, James Colson. This document is the second of a two-part analysis on Emergency Response Capabilities of Lawrence Livermore National Laboratory. The first part, 2016 Baseline Needs Assessment Requirements Document established the minimum performance criteria necessary to meet mandatory requirements. This second part analyses the performance of Lawrence Livermore Laboratory Emergency Management Department to the contents of the Requirements Document. The document was prepared based on an extensive review of information contained in the 2016more » BNA, a review of Emergency Planning Hazards Assessments, a review of building construction, occupancy, fire protection features, dispatch records, LLNL alarm system records, fire department training records, and fire department policies and procedures. The 2013 BNA was approved by NNSA’s Livermore Field Office on January 22, 2014.« less
Combustion Processes in the Aerospace Environment
NASA Technical Reports Server (NTRS)
Huggett, Clayton
1969-01-01
The aerospace environment introduces new and enhanced fire hazards because the special atmosphere employed may increase the frequency and intensity of fires, because the confinement associated with aerospace systems adversely affects the dynamics of fire development and control, and because the hostile external environments limit fire control and rescue operations. Oxygen enriched atmospheres contribute to the fire hazard in aerospace systems by extending the list of combustible fuels, increasing the probability of ignition, and increasing the rates of fire spread and energy release. A system for classifying atmospheres according to the degree of fire hazard, based on the heat capacity of the atmosphere per mole of oxygen, is suggested. A brief exploration of the dynamics of chamber fires shows that such fires will exhibit an exponential growth rate and may grow to dangerous size in a very short time. Relatively small quantities of fuel and oxygen can produce a catastrophic fire in a closed chamber.
NASA Astrophysics Data System (ADS)
Mahmud, Ahmad Rodzi; Setiawan, Iwan; Mansor, Shattri; Shariff, Abdul Rashid Mohamed; Pradhan, Biswajeet; Nuruddin, Ahmed
2009-12-01
A study in modeling fire hazard assessment will be essential in establishing an effective forest fire management system especially in controlling and preventing peat fire. In this paper, we have used geographic information system (GIS), in combination with other geoinformation technologies such as remote sensing and computer modeling, for all aspects of wild land fire management. Identifying areas that have a high probability of burning is an important component of fire management planning. The development of spatially explicit GIS models has greatly facilitated this process by allowing managers to map and analyze variables contributing to fire occurrence across large, unique geographic units. Using the model and its associated software engine, the fire hazard map was produced. Extensive avenue programming scripts were written to provide additional capabilities in the development of these interfaces to meet the full complement of operational software considering various users requirements. The system developed not only possesses user friendly step by step operations to deliver the fire vulnerability mapping but also allows authorized users to edit, add or modify parameters whenever necessary. Results from the model can support fire hazard mapping in the forest and enhance alert system function by simulating and visualizing forest fire and helps for contingency planning.
24 CFR 242.33 - Covenant for malpractice, fire, and other hazard insurance.
Code of Federal Regulations, 2010 CFR
2010-04-01
... for malpractice, fire, and other hazard insurance. The mortgage shall contain a covenant binding the mortgagor to maintain adequate liability, fire, and extended coverage insurance on the property. The... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Covenant for malpractice, fire, and...
Fire Hazard Assessment in Supporting Fire Protection System Design of a Chemical Process Facility
1996-08-01
CSDP/Studies/FireHaz –i– 3/28/97 FIRE HAZARD ASSESSMENT IN SUPPORTING FIRE PROTECTION SYSTEM DESIGN OF A CHEMICAL PROCESS FACILITY Ali Pezeshk...Joseph Chang, Dwight Hunt, and Peter Jahn Parsons Infrastructure & Technology Group, Inc. Pasadena, California 91124 ABSTRACT Because fires in a chemical ...Assessment in Supporting Fire Protection System Design of a Chemical Process Facility 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6
Fire Safety Power. Sixth Grade. Fire Safety for Texans: Fire and Burn Prevention Curriculum Guide.
ERIC Educational Resources Information Center
Texas State Commission on Fire Protection, Austin.
This booklet comprises the sixth grade component of a series of curriculum guides on fire and burn prevention. Designed to meet the age-specific needs of sixth grade students, its objectives include: (1) developing a comprehensive understanding of fire physics, (2) evaluating electrical hazards and how to respond to those hazards, and (3)…
R. James Barbour; Jeremy Fried; Peter J. Daugherty; Glenn Christensen; Roger. Fight
2008-01-01
The FIA BioSum model was used to simulate three fire-hazard-reduction policies in an area comprising northern California, southwestern Oregon, and the east slopes of the Cascade Mountains in Oregon. The policy scenarios, all subject to a stand-scale fire-hazard-reduction effectiveness constraint, included maximize torching index improvement (Max TI), maximize net...
Brandon M. Collins; Heather A. Kramer; Kurt Menning; Colin Dillingham; David Saah; Peter A. Stine; Scott L. Stephens
2013-01-01
We built on previous work by performing a more in-depth examination of a completed landscape fuel treatment network. Our specific objectives were: (1) model hazardous fire potential with and without the treatment network, (2) project hazardous fire potential over several decades to assess fuel treatment network longevity, and (3) assess fuel treatment effectiveness and...
Experimental Studies on the Flammability and Fire Hazards of Photovoltaic Modules
Yang, Hong-Yun; Zhou, Xiao-Dong; Yang, Li-Zhong; Zhang, Tao-Lin
2015-01-01
Many of the photovoltaic (PV) systems on buildings are of sufficiently high voltages, with potential to cause or promote fires. However, research about photovoltaic fires is insufficient. This paper focuses on the flammability and fire hazards of photovoltaic modules. Bench-scale experiments based on polycrystalline silicon PV modules have been conducted using a cone calorimeter. Several parameters including ignition time (tig), mass loss, heat release rate (HRR), carbon monoxide (CO) and carbon dioxide (CO2) concentration, were investigated. The fire behaviours, fire hazards and toxicity of gases released by PV modules are assessed based on experimental results. The results show that PV modules under tests are inflammable with the critical heat flux of 26 kW/m2. This work will lead to better understanding on photovoltaic fires and how to help authorities determine the appropriate fire safety provisions for controlling photovoltaic fires. PMID:28793434
Experimental Studies on the Flammability and Fire Hazards of Photovoltaic Modules.
Yang, Hong-Yun; Zhou, Xiao-Dong; Yang, Li-Zhong; Zhang, Tao-Lin
2015-07-09
Many of the photovoltaic (PV) systems on buildings are of sufficiently high voltages, with potential to cause or promote fires. However, research about photovoltaic fires is insufficient. This paper focuses on the flammability and fire hazards of photovoltaic modules. Bench-scale experiments based on polycrystalline silicon PV modules have been conducted using a cone calorimeter. Several parameters including ignition time ( t ig ), mass loss, heat release rate (HRR), carbon monoxide (CO) and carbon dioxide (CO₂) concentration, were investigated. The fire behaviours, fire hazards and toxicity of gases released by PV modules are assessed based on experimental results. The results show that PV modules under tests are inflammable with the critical heat flux of 26 kW/m². This work will lead to better understanding on photovoltaic fires and how to help authorities determine the appropriate fire safety provisions for controlling photovoltaic fires.
The potential for LiDAR technology to map fire fuel hazard over large areas of Australian forest.
Price, Owen F; Gordon, Christopher E
2016-10-01
Fuel load is a primary determinant of fire spread in Australian forests. In east Australian forests, litter and canopy fuel loads and hence fire hazard are thought to be highest at and beyond steady-state fuel loads 15-20 years post-fire. Current methods used to predict fuel loads often rely on course-scale vegetation maps and simple time-since-fire relationships which mask fine-scale processes influencing fuel loads. Here we use Light Detecting and Remote Sensing technology (LiDAR) and field surveys to quantify post-fire mid-story and crown canopy fuel accumulation and fire hazard in Dry Sclerophyll Forests of the Sydney Basin (Australia) at fine spatial-scales (20 × 20 m cell resolution). Fuel cover was quantified in three strata important for crown fire propagation (0.5-4 m, 4-15 m, >15 m) over a 144 km(2) area subject to varying fire fuel ages. Our results show that 1) LiDAR provided a precise measurement of fuel cover in each strata and a less precise but still useful predictor of surface fuels, 2) cover varied greatly within a mapped vegetation class of the same fuel age, particularly for elevated fuel, 3) time-since-fire was a poor predictor of fuel cover and crown fire hazard because fuel loads important for crown fire propagation were variable over a range of fire fuel ages between 2 and 38 years post-fire, and 4) fuel loads and fire hazard can be high in the years immediately following fire. Our results show the benefits of spatially and temporally specific in situ fuel sampling methods such as LiDAR, and are widely applicable for fire management actions which aim to decrease human and environmental losses due to wildfire. Copyright © 2016 Elsevier Ltd. All rights reserved.
Diakakis, M; Nikolopoulos, E I; Mavroulis, S; Vassilakis, E; Korakaki, E
2017-08-15
Even though rare, mega-fires raging during very dry and windy conditions, record catastrophic impacts on infrastructure, the environment and human life, as well as extremely high suppression and rehabilitation costs. Apart from the direct consequences, mega-fires induce long-term effects in the geomorphological and hydrological processes, influencing environmental factors that in turn can affect the occurrence of other natural hazards, such as floods and mass movement phenomena. This work focuses on the forest fire of 2007 in Peloponnese, Greece that to date corresponds to the largest fire in the country's record that burnt 1773km 2 , causing 78 fatalities and very significant damages in property and infrastructure. Specifically, this work examines the occurrence of flood and mass movement phenomena, before and after this mega-fire and analyses different influencing factors to investigate the degree to which the 2007 fire and/or other parameters have affected their frequency. Observational evidence based on several data sources collected during the period 1989-2016 show that the 2007 fire has contributed to an increase of average flood and mass movement events frequency by approximately 3.3 and 5.6 times respectively. Fire affected areas record a substantial increase in the occurrence of both phenomena, presenting a noticeably stronger increase compared to neighbouring areas that have not been affected. Examination of the monthly occurrence of events showed an increase even in months of the year were rainfall intensity presented decreasing trends. Although no major land use changes has been identified and chlorophyll is shown to recover 2years after the fire incident, differences on the type of vegetation as tall forest has been substituted with lower vegetation are considered significant drivers for the observed increase in flood and mass movement frequency in the fire affected areas. Copyright © 2017 Elsevier B.V. All rights reserved.
Fire hazards at the urban-wildland interface: What the public expects
NASA Astrophysics Data System (ADS)
Cortner, Hanna J.; Gardner, Philip D.; Taylor, Jonathan G.
1990-01-01
Urban-wildland issues have become among the most contentious and problematic issues for forest managers. Using data drawn from surveys conducted by the authors and others, this article discusses how public knowledge and perceptions of fire policies and fire hazards change over time, the kinds of policy responses homeowners prefer as a way of preventing fire hazards at the urban-wildland interface, and how citizens view their own obligations as participants in interface issues. These data show that public attitudes toward fire have changed significantly over the past two decades and that educating the public about fire and the managers' use of fire can have positive effects on behavior. Yet, modifying the individual's behavior in regard to interface fire risks must also deal with important issues of individual incentives, the distribution of costs, and unanticipated policy impacts.
Fire hazards at the urban-wildland interface: what the public expects
Cortner, Hanna J.; Gardner, Philip D.; Taylor, Jonathan G.
1990-01-01
Urban-wildland issues have become among the most contentious and problematic issues for forest managers. Using data drawn from surveys conducted by the authors and others, this article discusses how public knowledge and perceptions of fire policies and fire hazards change over time, the kinds of policy responses homeowners prefer as a way of preventing fire hazards at the urban-wildland interface, and how citizens view their own obligations as participants in interface issues. These data show that public attitudes toward fire have changed significantly over the past two decades and that educating the public about fire and the managers' use of fire can have positive effects on behavior. Yet, modifying the individual's behavior in regard to interface fire risks must also deal with important issues of individual incentives, the distribution of costs, and unanticipated policy impacts.
Understanding the long-term fire risks in forests affected by sudden oak death
Yana Valachovic; Chris Lee; Radoslaw Glebocki; Hugh Scanlon; J. Morgan Varner; David Rizzo
2010-01-01
It is assumed that large numbers of dead and down tanoak in forests infested by Phytophthora ramorum contribute to increased fire hazard risk and fuel loading. We studied the impact of P. ramorum infestation on surface fuel loading, potential fire hazard, and potential fire behavior in Douglas-fir- (Pseudotsuga...
Roger D. Fight; R. James Barbour; Glenn Christensen; Guy L. Pinjuv; Rao V. Nagubadi
2004-01-01
This work was undertaken under a joint fire science project "Assessing the need, costs, and potential benefits of prescribed fire and mechanical treatments to reduce fire hazard." This paper compares the future mix of timber projects under two treatment scenarios for New Mexico.We developed and demonstrated an analytical method that uses readily available...
R. James Barbour; Roger D. Fight; Glenn A. Christensen; Guy L. Pinjuv; Rao V. Nagubadi
2004-01-01
This work was undertaken under a joint fire science project "Assessing the need, costs, and potential benefits of prescribed fire and mechanical treatments to reduce fire hazard." This paper compares the future mix of timber products under two treatment scenarios for the state of Montana. We developed and demonstrated an analytical method that uses readily...
NASA Astrophysics Data System (ADS)
Mouillot, F.; Koutsias, N.; Conedera, M.; Pezzatti, B.; Madoui, A.; Belhadj Kheder, C.
2017-12-01
Wildfire is the main disturbance affecting Mediterranean ecosystems, with implications on biogeochemical cycles, biosphere/atmosphere interactions, air quality, biodiversity, and socio-ecosystems sustainability. The fire/climate relationship is time-scale dependent and may additionally vary according to concurrent changes climatic, environmental (e.g. land use), and fire management processes (e.g. fire prevention and control strategies). To date, however, most studies focus on a decadal scale only, being fire statistics ore remote sensing data usually available for a few decades only. Long-term fire data may allow for a better caption of the slow-varying human and climate constrains and for testing the consistency of the fire/climate relationship on the mid-time to better apprehend global change effects on fire risks. Dynamic Global Vegetation Models (DGVMs) associated with process-based fire models have been recently developed to capture both the direct role of climate on fire hazard and the indirect role of changes in vegetation and human population, to simulate biosphere/atmosphere interactions including fire emissions. Their ability to accurately reproduce observed fire patterns is still under investigation regarding seasonality, extreme events or temporal trend to identify potential misrepresentations of processes. We used a unique long-term fire reconstruction (from 1880 to 2016) of yearly burned area along a North/South and East/West environmental gradient across the Mediterranean Basin (southern Switzerland, Greece, Algeria, Tunisia) to capture the climatic and socio economic drivers of extreme fire years by linking yearly burned area with selected climate indices derived from historical climate databases and socio-economic variables. We additionally compared the actual historical reconstructed fire history with the yearly burned area simulated by a panel of DGVMS (FIREMIP initiative) driven by daily CRU climate data at 0.5° resolution across the Mediterranean basin. We will present and discuss the key processes driving interannual fire hazard along the 20th century, and analysed how DGVMs capture this interannual variability.
Manned spacecraft electrical fire safety
NASA Technical Reports Server (NTRS)
Wardell, A. W.
1971-01-01
The fire hazards created in spacecraft compartments by malfunction of electrical wiring are described. The tests for electrical wire/cable current overload flammability are presented. The application of electrical and material technologies to the reduction of fire hazards in spacecraft are examined.
29 CFR 1915.501 - General provisions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... safety plan including hazards, controls, fire safety and health rules, and emergency procedures; (ii... (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard... require employers to protect all employees from fire hazards in shipyard employment, including employees...
29 CFR 1915.501 - General provisions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... safety plan including hazards, controls, fire safety and health rules, and emergency procedures; (ii... (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard... require employers to protect all employees from fire hazards in shipyard employment, including employees...
29 CFR 1915.501 - General provisions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... safety plan including hazards, controls, fire safety and health rules, and emergency procedures; (ii... (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard... require employers to protect all employees from fire hazards in shipyard employment, including employees...
Natural Hazards and the press in the western Mediterranean region
NASA Astrophysics Data System (ADS)
Llasat-Botija, M.; Llasat, M. C.; López, L.
2007-07-01
This study analyses press articles published between 1982 and 2005 in an attempt to describe the social perception of natural hazards in Catalonia. The articles included in the database have been classified according to different types of risk. In addition, the study examines the evolution of each type of risk in the press coverage during the study period. Finally, the results have been compared to data provided by insurance companies with respect to compensations paid out for damages. Conclusions show that floods are the most important natural hazard in the region, but that the number of headlines for each event is greater in the case of snowfalls and forest fires. Factors such as the season of the year, the proximity of the affected region to the capital, the topical issues at the time, and the presence of other important news must be considered when the impact in the press is analysed.
Analysis of the prescribed burning practice in the pine forest of northwestern Portugal.
Fernandes, P; Botelho, H
2004-01-01
The ignition of low-intensity fires in the dormant season in the pine stands of north-western Portugal seeks to reduce the existing fuel hazard without compromising site quality. The purpose of this study is to characterise this practice and assess its effectiveness, based on information resulting from the normal monitoring process at the management level, and using operational guidelines, fire behaviour models and a newly developed method to classify prescribed fire severity. Although the region's humid climate strongly constrains the activity of prescribed fire, 87% of the fires analysed were undertaken under acceptable meteorological and fuel moisture conditions. In fact, most operations achieved satisfactory results. On average, prescribed fire reduces by 96% the potential intensity of a wildfire occurring under extreme weather conditions, but 36% of the treated sites would still require heavy fire fighting resources to suppress such fire, and 17% would still carry it in the tree canopy. Only 10% of the prescribed burns have an excessive impact on trees or the forest floor, while 89% (normal fire weather) or 59% (extreme fire weather) comply with both ecological integrity maintenance and wildfire protection needs. Improved planning and monitoring procedures are recommended in order to overcome the current deficiencies.
Litton, Charles D.; Perera, Inoka E.; Harteis, Samuel P.; Teacoach, Kara A.; DeRosa, Maria I.; Thomas, Richard A.; Smith, Alex C.
2018-01-01
When combustible materials ignite and burn, the potential for fire growth and flame spread represents an obvious hazard, but during these processes of ignition and flaming, other life hazards present themselves and should be included to ensure an effective overall analysis of the relevant fire hazards. In particular, the gases and smoke produced both during the smoldering stages of fires leading to ignition and during the advanced flaming stages of a developing fire serve to contaminate the surrounding atmosphere, potentially producing elevated levels of toxicity and high levels of smoke obscuration that render the environment untenable. In underground mines, these hazards may be exacerbated by the existing forced ventilation that can carry the gases and smoke to locations far-removed from the fire location. Clearly, materials that require high temperatures (above 1400 K) and that exhibit low mass loss during thermal decomposition, or that require high heat fluxes or heat transfer rates to ignite represent less of a hazard than materials that decompose at low temperatures or ignite at low levels of heat flux. In order to define and quantify some possible parameters that can be used to assess these hazards, small-scale laboratory experiments were conducted in a number of configurations to measure: 1) the toxic gases and smoke produced both during non-flaming and flaming combustion; 2) mass loss rates as a function of temperature to determine ease of thermal decomposition; and 3) mass loss rates and times to ignition as a function of incident heat flux. This paper describes the experiments that were conducted, their results, and the development of a set of parameters that could possibly be used to assess the overall fire hazard of combustible materials using small scale laboratory experiments. PMID:29599565
Litton, Charles D; Perera, Inoka E; Harteis, Samuel P; Teacoach, Kara A; DeRosa, Maria I; Thomas, Richard A; Smith, Alex C
2018-04-15
When combustible materials ignite and burn, the potential for fire growth and flame spread represents an obvious hazard, but during these processes of ignition and flaming, other life hazards present themselves and should be included to ensure an effective overall analysis of the relevant fire hazards. In particular, the gases and smoke produced both during the smoldering stages of fires leading to ignition and during the advanced flaming stages of a developing fire serve to contaminate the surrounding atmosphere, potentially producing elevated levels of toxicity and high levels of smoke obscuration that render the environment untenable. In underground mines, these hazards may be exacerbated by the existing forced ventilation that can carry the gases and smoke to locations far-removed from the fire location. Clearly, materials that require high temperatures (above 1400 K) and that exhibit low mass loss during thermal decomposition, or that require high heat fluxes or heat transfer rates to ignite represent less of a hazard than materials that decompose at low temperatures or ignite at low levels of heat flux. In order to define and quantify some possible parameters that can be used to assess these hazards, small-scale laboratory experiments were conducted in a number of configurations to measure: 1) the toxic gases and smoke produced both during non-flaming and flaming combustion; 2) mass loss rates as a function of temperature to determine ease of thermal decomposition; and 3) mass loss rates and times to ignition as a function of incident heat flux. This paper describes the experiments that were conducted, their results, and the development of a set of parameters that could possibly be used to assess the overall fire hazard of combustible materials using small scale laboratory experiments.
Forest fuels and landscape-level fire risk assessment of the ozark highlands, Missouri
Michael C. Stambaugh; Richard P. Guyette; Daniel C. Dey
2007-01-01
In this paper we describe a fire risk assessment of the Ozark Highlands. Fire risk is rated using information on ignition potential and fuel hazard. Fuel loading, a component of the fire hazard module, is weakly predicted (r2 = 0.19) by site- and landscape-level attributes. Fuel loading does not significantly differ between Ozark ecological...
Chemical Safety Alert: Fire Hazard from Carbon Adsorption Deodorizing Systems
Activated carbon systems used to adsorb vapors for odor control may pose a fire hazard when used for certain types of substances, such as crude sulfate turpentine. Facilities should take precautions and proper procedures to avoid or mitigate these hazards.
77 FR 21961 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-12
... the responses of California and Colorado residents to different scenarios related to fire hazard... researchers provide better information to natural resources, forest, and fire managers when they are contemplating the kind and type of fire hazard reduction programs to implement to achieve forest land management...
Stephen Brewer; Corey Rogers
2006-01-01
Using Geographic Information Systems and US Forest Service data, we examined relationships between prescribed burning (from 1979 to 2000) and the incidence, size, and intensity of wildfires (from 1995 to 2000) in a landscape containing formerly fire-suppressed, closed-canopy hardwood and pine-hardwood forests. Results of hazard (failure) analyses did not show an...
Ignorance and Hazards in Academe: The Dilemma of Fire Safety in American Higher Education.
ERIC Educational Resources Information Center
Crnkovich, John J.; Dye, Charles M.
An examination was made of five major campus fires between 1971 and 1983 in an attempt to better understand the fire hazards associated with the operation of a modern U.S. college or university campus. Overall research revealed a general lack of interest in campus fire safety by colleges and universities in the United States and Canada. Analysis…
Fuel and fire behavior in high-elevation five-needle pines affected by mountain pine beetle
Michael J. Jenkins
2011-01-01
Bark beetle-caused tree mortality in conifer forests affects the quantity and quality of forest fuels and has long been assumed to increase fire hazard and potential fire behavior. In reality, bark beetles and their effects on fuel accumulation and subsequent fire hazard have only recently been described. We have extensively sampled fuels in three conifer forest types...
An assessment of the crash fire hazard of liquid hydrogen fueled aircraft
NASA Technical Reports Server (NTRS)
1982-01-01
The crash fire hazards of liquid hydrogen fueled aircraft relative to those of mission equivalent aircraft fueled either with conventional fuel or with liquefied methane were evaluated. The aircraft evaluated were based on Lockheed Corporation design for 400 passenger, Mach 0.85, 5500 n. mile aircraft. Four crash scenarios were considered ranging from a minor incident causing some loss of fuel system integrity to a catastrophic crash. Major tasks included a review of hazardous properties of the alternate fuels and of historic crash fire data; a comparative hazard evluation for each of the three fuels under four crash scenarios a comprehensive review and analysis and an identification of areas further development work. The conclusion was that the crash fire hazards are not significantly different when compared in general for the three fuels, although some fuels showed minor advantages in one respect or another.
33 CFR 127.1507 - Water systems for fire protection.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Water systems for fire protection... HAZARDOUS GAS Waterfront Facilities Handling Liquefied Hazardous Gas Firefighting Equipment § 127.1507 Water systems for fire protection. (a) Each waterfront facility handling LHG must have a supply of water and a...
29 CFR 1926.352 - Fire prevention.
Code of Federal Regulations, 2011 CFR
2011-07-01
... penetration of sparks or heat transfer may introduce a fire hazard to an adjacent area, the same precautions... confine the heat, sparks, and slag, and to protect the immovable fire hazards from them. (c) No welding...-consuming device. (h) Except when the contents are being removed or transferred, drums, pails, and other...
The Elimination of Fire Hazard Due to Back Fires
NASA Technical Reports Server (NTRS)
Theodorsen, Theodore; Freeman, Ira M
1933-01-01
A critical study was made of the operation of a type of back-fire arrester used to reduce the fire hazard of aircraft engines. A flame arrester consisting of a pack or plug of alternate flat and corrugated plates of thin metal was installed in the intake pipe of a gasoline engines; an auxiliary spark plug inserted in the intake manifold permitted the production of artificial back fires at will. It was found possible to design a plug which prevented all back fires from reaching the carburetor.
Determination of the fire hazards of mine materials using a radiant panel.
Harteis, S P; Litton, C D; Thomas, R A
2016-01-01
The objective of this study was to develop a laboratory-scale method to rank the ignition and fire hazards of commonly used underground mine materials and to eliminate the need for the expensive large-scale tests that are currently being used. A radiant-panel apparatus was used to determine the materials' relevant thermal characteristics: time to ignition, critical heat flux for ignition, heat of gasification, and mass-loss rate. Three thermal parameters, TRP , TP1 and TP4 , were derived from the data, then developed and subsequently used to rank the combined ignition and fire hazards of the combustible materials from low hazard to high hazard. The results compared favorably with the thermal and ignition hazards of similar materials reported in the literature and support this approach as a simpler one for quantifying these combustible hazards.
Estimating Woody Biomass Supply From Thinning Treatments to Reduce Fire Hazard in the U.S. West
Kenneth E. Skog; R. James Barbour
2006-01-01
This paper identifies timberland areas in 12 western states where thinning treatments (1) are judged to be needed to reduce fire hazard and (2) may âpay for themselvesâ at a scale to make investment in forest product processing a realistic option. A web-based tool - Fuel Treatment Evaluator 3.0 - is used to select high-fire-hazard timberland plots from the Forest...
Summaries of BFRL fire research in-house projects and grants, 1993
NASA Astrophysics Data System (ADS)
Jason, Nora H.
1993-09-01
The report describes the fire research projects performed in the Building and Fire Research Laboratory (BFRL) and under its extramural grants program during fiscal year 1993. The BFRL Fire Research Program has directed its efforts under three program thrusts. The in-house priority projects, grants, and externally-funded efforts thus form an integrated, focussed ensemble. The publication is organized along those lines: fire risk and hazard prediction - carbon monoxide prediction, turbulent combustion, soot, engineering analysis, fire hazard assessment, and large fires; fire safety of products and materials - materials combustion, furniture flammability, and wall and ceiling fires; and advanced technologies for fire sensing and control - fire detection and fire suppression. For the convenience of the reader, an alphabetical listing of all grants is contained in Part 2.0.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coleman, Justin; Slaughter, Andrew; Veeraraghavan, Swetha
Multi-hazard Analysis for STOchastic time-DOmaiN phenomena (MASTODON) is a finite element application that aims at analyzing the response of 3-D soil-structure systems to natural and man-made hazards such as earthquakes, floods and fire. MASTODON currently focuses on the simulation of seismic events and has the capability to perform extensive ‘source-to-site’ simulations including earthquake fault rupture, nonlinear wave propagation and nonlinear soil-structure interaction (NLSSI) analysis. MASTODON is being developed to be a dynamic probabilistic risk assessment framework that enables analysts to not only perform deterministic analyses, but also easily perform probabilistic or stochastic simulations for the purpose of risk assessment.
75 FR 69032 - Naval Surface Warfare Center, Potomac River, Dahlgren, VA; Danger Zone
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-10
... hazardous operations such as firing large and small caliber guns and projectiles, aerial bombing, use of... protect the public from hazardous operations such as firing large and small caliber guns and projectiles... zone to include firing of large or small caliber guns and projectiles, aerial bombing, use of directed...
Coarse woody debris: Managing benefits and fire hazard in the recovering forest
James K. Brown; Elizabeth D. Reinhardt; Kylie A. Kramer
2003-01-01
Management of coarse woody debris following fire requires consideration of its positive and negative values. The ecological benefits of coarse woody debris and fire hazard considerations are summarized. This paper presents recommendations for desired ranges of coarse woody debris. Example simulations illustrate changes in debris over time and with varying management....
Characterizing crown fuel distribution for conifers in the interior western United States
Seth Ex; Frederick W. Smith; Tara Keyser
2015-01-01
Canopy fire hazard evaluation is essential for prioritizing fuel treatments and for assessing potential risk to firefighters during suppression activities. Fire hazard is usually expressed as predicted potential fire behavior, which is sensitive to the methodology used to quantitatively describe fuel profiles: methodologies that assume that fuel is distributed...
NASA Technical Reports Server (NTRS)
Enders, J. H.
1978-01-01
NASA's aviation safety technology program examines specific safety problems associated with atmospheric hazards, crash-fire survival, control of aircraft on runways, human factors, terminal area operations hazards, and accident factors simulation. While aircraft occupants are ultimately affected by any of these hazards, their well-being is immediately impacted by three specific events: unexpected turbulence encounters, fire and its effects, and crash impact. NASA research in the application of laser technology to the problem of clear air turbulence detection, the development of fire resistant materials for aircraft construction, and to the improvement of seats and restraint systems to reduce crash injuries are reviewed.
Assessing Surface Fuel Hazard in Coastal Conifer Forests through the Use of LiDAR Remote Sensing
NASA Astrophysics Data System (ADS)
Koulas, Christos
The research problem that this thesis seeks to examine is a method of predicting conventional fire hazards using data drawn from specific regions, namely the Sooke and Goldstream watershed regions in coastal British Columbia. This thesis investigates whether LiDAR data can be used to describe conventional forest stand fire hazard classes. Three objectives guided this thesis: to discuss the variables associated with fire hazard, specifically the distribution and makeup of fuel; to examine the relationship between derived LiDAR biometrics and forest attributes related to hazard assessment factors defined by the Capitol Regional District (CRD); and to assess the viability of the LiDAR biometric decision tree in the CRD based on current frameworks for use. The research method uses quantitative datasets to assess the optimal generalization of these types of fire hazard data through discriminant analysis. Findings illustrate significant LiDAR-derived data limitations, and reflect the literature in that flawed field application of data modelling techniques has led to a disconnect between the ways in which fire hazard models have been intended to be used by scholars and the ways in which they are used by those tasked with prevention of forest fires. It can be concluded that a significant trade-off exists between computational requirements for wildfire simulation models and the algorithms commonly used by field teams to apply these models with remote sensing data, and that CRD forest management practices would need to change to incorporate a decision tree model in order to decrease risk.
NASA Astrophysics Data System (ADS)
Jones, L. M.; Bawden, G. W.; Bowers, J.; Cannon, S.; Cox, D. A.; Fisher, R.; Keeley, J.; Perry, S. C.; Plumlee, G. S.; Wood, N. J.
2009-12-01
The “Station” fire, the largest fire in the history of Los Angeles County in southern California, began on August 26, 2009 and as of the abstract deadline had burned over 150,000 acres of the Angeles National Forest. This fire creates both a demand and an opportunity for hazards science to be used by the communities directly hit by the fire, as well as those downstream of possible postfire impacts. The Multi Hazards Demonstration Project of the USGS is deploying several types of scientific response, including 1) evaluation of potential debris-flow hazards and associated risk, 2) monitoring physical conditions in burned areas and the hydrologic response to rainstorms, 3) increased streamflow monitoring, 4) ash analysis and ground water contamination, 5) ecosystem response and endangered species rescue, 6) lidar data acquisition for evaluations of biomass loss, detailed mapping of the physical processes that lead to debris-flow generation, and other geologic investigations. The Multi Hazards Demonstration Project is working with the southern California community to use the resulting information to better manage the social consequences of the fire and its secondary hazards. In particular, we are working with Los Angeles County to determine what information they need to prioritize recovery efforts. For instance, maps of hazards specific to debris flow potential can help identify the highest priority areas for debris flow mitigation efforts. These same maps together with ecosystem studies will help land managers determine whether individuals from endangered species should be removed to zoos or other refuges during the rainy months. The ash analysis will help water managers prevent contamination to water supplies. Plans are just beginning for a public information campaign with Los Angeles County about the risk posed by potential debris flows that should be underway in December. Activities from the fire response will support the development of the Wildfire Scenario in 2011, which will examine implications of land-use decisions in the frequency of fires in southern California.
Zeng, Yuanyuan; Sreenan, Cormac J; Sitanayah, Lanny; Xiong, Naixue; Park, Jong Hyuk; Zheng, Guilin
2011-01-01
Fire hazard monitoring and evacuation for building environments is a novel application area for the deployment of wireless sensor networks. In this context, adaptive routing is essential in order to ensure safe and timely data delivery in building evacuation and fire fighting resource applications. Existing routing mechanisms for wireless sensor networks are not well suited for building fires, especially as they do not consider critical and dynamic network scenarios. In this paper, an emergency-adaptive, real-time and robust routing protocol is presented for emergency situations such as building fire hazard applications. The protocol adapts to handle dynamic emergency scenarios and works well with the routing hole problem. Theoretical analysis and simulation results indicate that our protocol provides a real-time routing mechanism that is well suited for dynamic emergency scenarios in building fires when compared with other related work.
Zeng, Yuanyuan; Sreenan, Cormac J.; Sitanayah, Lanny; Xiong, Naixue; Park, Jong Hyuk; Zheng, Guilin
2011-01-01
Fire hazard monitoring and evacuation for building environments is a novel application area for the deployment of wireless sensor networks. In this context, adaptive routing is essential in order to ensure safe and timely data delivery in building evacuation and fire fighting resource applications. Existing routing mechanisms for wireless sensor networks are not well suited for building fires, especially as they do not consider critical and dynamic network scenarios. In this paper, an emergency-adaptive, real-time and robust routing protocol is presented for emergency situations such as building fire hazard applications. The protocol adapts to handle dynamic emergency scenarios and works well with the routing hole problem. Theoretical analysis and simulation results indicate that our protocol provides a real-time routing mechanism that is well suited for dynamic emergency scenarios in building fires when compared with other related work. PMID:22163774
NASA Astrophysics Data System (ADS)
Maltzkait, Anika; Pfurtscheller, Clemens
2014-05-01
Multihazard risk analysis and disaster planning for emergency services as a basis for efficient provision in the case of natural hazards - case study municipality of Au, Austria A. Maltzkait (1) & C. Pfurtscheller (1) (1) Institute for Interdisciplinary Mountain Research (IGF), Austrian Academy of Sciences, Innsbruck, Austria The extreme flood events of 2002, 2005 and 2013 in Austria underlined the importance of local emergency services being able to withstand and reduce the adverse impacts of natural hazards. Although for legal reasons municipal emergency and crisis management plans exist in Austria, they mostly do not cover risk analyses of natural hazards - a sound, comparable assessment to identify and evaluate risks. Moreover, total losses and operational emergencies triggered by natural hazards have increased in recent decades. Given sparse public funds, objective budget decisions are needed to ensure the efficient provision of operating resources, like personnel, vehicles and equipment in the case of natural hazards. We present a case study of the municipality of Au, Austria, which was hardly affected during the 2005 floods. Our approach is primarily based on a qualitative risk analysis, combining existing hazard plans, GIS data, field mapping and data on operational efforts of the fire departments. The risk analysis includes a map of phenomena discussed in a workshop with local experts and a list of risks as well as a risk matrix prepared at that workshop. On the basis for the exact requirements for technical and non-technical mitigation measures for each natural hazard risk were analysed in close collaboration with members of the municipal operation control and members of the local emergency services (fire brigade, Red Cross). The measures includes warning, evacuation and, technical interventions with heavy equipment and personnel. These results are used, first, to improve the municipal emergency and crisis management plan by providing a risk map, and a list of risks and, second, to check if the local emergency forces can cope with the different risk scenarios using locally available resources. The emergency response plans will identify possible resource deficiencies in personnel, vehicles and equipment. As qualitative methods and data are used, uncertainties in the study emerged in finding definitions for safety targets, in the construction of the different risk scenarios, in the inherent uncertainty beyond the probability of occurrence and the intensity of natural hazards, also in the case of the expectable losses. Finally, we used available studies and expert interviews to develop objective rules for investment decisions for the fire departments and the Red Cross to present an empirically sound basis for the efficient provision of intervention in the case of natural hazards for the municipality of Au. Again, the regulations for objective provision were developed in close collaboration with the emergency services.
Ćujić, Mirjana; Dragović, Snežana; Đorđević, Milan; Dragović, Ranko; Gajić, Boško; Miljanić, Šćepan
2015-07-01
Primordial radionuclides, (238)U, (232)Th and (40)K were determined in soil samples collected at two depths (0-10 and 10-20 cm) in the vicinity of the largest coal-fired power plant in Serbia, and their spatial distribution was analysed using ordinary kriging. Mean values of activity concentrations for these depths were 50.7 Bq kg(-1) for (238)U, 48.7 Bq kg(-1) for (232)Th and 560 Bq kg(-1) for (40)K. Based on the measured activity concentrations, the radiological hazard due to naturally occurring radionuclides in soil was assessed. The value of the mean total absorbed dose rate was 76.3 nGy h(-1), which is higher than the world average. The annual effective dose due to these radionuclides ranged from 51.4 to 114.2 μSv. Applying cluster analysis, correlations between radionuclides and soil properties were determined. The distribution pattern of natural radionuclides in the environment surrounding the coal-fired power plant and their enrichment in soil at some sampling sites were in accordance with dispersion models of fly ash emissions. From the results obtained, it can be concluded that operation of the coal-fired power plant has no significant negative impact on the surrounding environment with regard to the content of natural radionuclides.
Wildfire risk and hazard: procedures for the first approximation
David E. Calkin; Alan A. Ager; Julie Gilbertson-Day
2010-01-01
This report was designed to meet three broad goals: (1) evaluate wildfire hazard on Federal lands; (2) develop information useful in prioritizing where fuels treatments and mitigation measures might be proposed to address significant fire hazard and risk; and (3) develop risk-based performance measures to document the effectiveness of fire management programs. The...
Evaluating fuel complexes for fire hazard mitigation planning in the southeastern United States
Anne G. Andreu; Dan Shea; Bernard R. Parresol; Roger D. Ottmar
2012-01-01
Fire hazard mitigation planning requires an accurate accounting of fuel complexes to predict potential fire behavior and effects of treatment alternatives. In the southeastern United States, rapid vegetation growth coupled with complex land use history and forest management options requires a dynamic approach to fuel characterization. In this study we assessed...
Integrating remote sensing and terrain data in forest fire modeling
NASA Astrophysics Data System (ADS)
Medler, Michael Johns
Forest fire policies are changing. Managers now face conflicting imperatives to re-establish pre-suppression fire regimes, while simultaneously preventing resource destruction. They must, therefore, understand the spatial patterns of fires. Geographers can facilitate this understanding by developing new techniques for mapping fire behavior. This dissertation develops such techniques for mapping recent fires and using these maps to calibrate models of potential fire hazards. In so doing, it features techniques that strive to address the inherent complexity of modeling the combinations of variables found in most ecological systems. Image processing techniques were used to stratify the elements of terrain, slope, elevation, and aspect. These stratification images were used to assure sample placement considered the role of terrain in fire behavior. Examination of multiple stratification images indicated samples were placed representatively across a controlled range of scales. The incorporation of terrain data also improved preliminary fire hazard classification accuracy by 40%, compared with remotely sensed data alone. A Kauth-Thomas transformation (KT) of pre-fire and post-fire Thematic Mapper (TM) remotely sensed data produced brightness, greenness, and wetness images. Image subtraction indicated fire induced change in brightness, greenness, and wetness. Field data guided a fuzzy classification of these change images. Because fuzzy classification can characterize a continuum of a phenomena where discrete classification may produce artificial borders, fuzzy classification was found to offer a range of fire severity information unavailable with discrete classification. These mapped fire patterns were used to calibrate a model of fire hazards for the entire mountain range. Pre-fire TM, and a digital elevation model produced a set of co-registered images. Training statistics were developed from 30 polygons associated with the previously mapped fire severity. Fuzzy classifications of potential burn patterns were produced from these images. Observed field data values were displayed over the hazard imagery to indicate the effectiveness of the model. Areas that burned without suppression during maximum fire severity are predicted best. Areas with widely spaced trees and grassy understory appear to be misrepresented, perhaps as a consequence of inaccuracies in the initial fire mapping.
Managing forest structure and fire hazard--a tool for planners.
M.C. Johnson; D.L. Peterson; C.L. Raymond
2006-01-01
Fire planners and other resource managers need to examine a range of potential fuel and vegetation treatments to select options that will lead to desired outcomes for fire hazard and natural resource conditions. A new approach to this issue integrates concepts and tools from silviculture and fuel science to quantify outcomes for a large number of treatment options in...
Follow-up evaluation of fire hazard inspection procedures...Butte County, California
William S. Folkman
1968-01-01
A study made in 1966 in Butte County, Calif., to assess the effectiveness of fire hazard inspection procedures was repeated in 1967. Purpose of the inspections is to secure compliance with fire safety requirements. The observed drop in number of violations suggests a carryover effect in 1967 from the first study. In many cases, personal contact was still necessary to...
Small-diameter timber alchemy: can utilization pay the way toward fire-resistant forests
Jeremy S. Fried; R. Jamie Barbour; Roger D. Fight; Glenn Christensen; Guy Pinjuv
2008-01-01
There is growing interest in using biomass removed from hazardous fuels reduction treatments in wood-fired electrical generation facilities. An application of FIA BioSum to southwest Oregonâs Klamath ecoregion assessed the financial feasibility of fuel treatment and biomass generation under a range of product prices and fire hazard-motivated silvicultural prescriptions...
Steve Slaughter; Laura Ward; Michael Hillis; Jim Chew; Rebecca McFarlan
2004-01-01
Forest Service managers and researchers designed and evaluated alternative disturbance-based fire hazard reduction/ecosystem restoration treatments in a greatly altered low-elevation ponderosa pine/Douglas-fir/western larch wildland urban interface. Collaboratively planned improvement cutting and prescribed fire treatment alternatives were evaluated in simulations of...
2013-07-18
are subject to damage and abrasion (figure 5). The use of an extension cord instead of fixed wiring creates the possibility of fire , electrical shock...Medical Clinic has an adjacent warehouse that is of a higher hazard and is not separated by 1-hour fire resistance rated construction. KMC 17-May...higher hazard and is not separated by 1-hour fire resistance rated construction. DynCorp NO Awaiting USG Decision DI has not received governmental
Fire Control Agent Effectiveness for Hazardous Chemical Fires: Carbon Disulfide.
1981-01-01
Fires..................................... 46 12. AFFF Fire Control Data for Carbon Disulfide Fires............................. 47 13. Extinguishment...Disulfide and Hexane Fires ....... 67 22. Comparison of AFFF Fire Control Times for Carbon Disulfide and Hexane Fires ................... 68 23. Comparison of...Data .............. 27 2. Summary of Fluoroprotein Foam Fire Test Data ....... 28 3. Summary of AFFF Fire Test Data ..................... 29 4. Summary
Reducing fire hazard in ponderosa pine thinning slash by mechanical crushing
John R. Dell; Franklin R. Ward
1969-01-01
Precommercial thinning in ponderosa pine stands in the Western United States is a growing practice. Thinning slash can, however, be a serious fire hazard in dry areas. Crushing and compacting this slash may be one way of reducing the hazard. Three types of mechanical crushers were tested on the Deschutes National Forest, Oregon. Results indicate that at least one of...
Joseph J. O’Brien; Kathryn A. Mordecai; Leslie Wolcott
2010-01-01
This publication is a field guide to tactics and techniques for dealing with hazardous fuels in subtropical pine flatwoods and tropical pine rocklands. The guide covers prescribed fire, mechanical, chemical, and other means for reducing and managing wildland fuels in these systems. Also, a list of exotic plants that contribute to hazardous fuel problems is included...
Landslides, forest fires, and earthquakes: examples of self-organized critical behavior
NASA Astrophysics Data System (ADS)
Turcotte, Donald L.; Malamud, Bruce D.
2004-09-01
Per Bak conceived self-organized criticality as an explanation for the behavior of the sandpile model. Subsequently, many cellular automata models were found to exhibit similar behavior. Two examples are the forest-fire and slider-block models. Each of these models can be associated with a serious natural hazard: the sandpile model with landslides, the forest-fire model with actual forest fires, and the slider-block model with earthquakes. We examine the noncumulative frequency-area statistics for each natural hazard, and show that each has a robust power-law (fractal) distribution. We propose an inverse-cascade model as a general explanation for the power-law frequency-area statistics of the three cellular-automata models and their ‘associated’ natural hazards.
Emergency Response Capability Baseline Needs Assessment Compliance Assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sharry, John A.
2013-09-16
This document is the second of a two-part analysis of Emergency Response Capabilities of Lawrence Livermore National Laboratory. The first part, 2013 Baseline Needs Assessment Requirements Document established the minimum performance criteria necessary to meet mandatory requirements. This second part analyses the performance of Lawrence Livermore Laboratory Emergency Management Department to the contents of the Requirements Document. The document was prepared based on an extensive review of information contained in the 2009 BNA, the 2012 BNA document, a review of Emergency Planning Hazards Assessments, a review of building construction, occupancy, fire protection features, dispatch records, LLNL alarm system records, firemore » department training records, and fire department policies and procedures.« less
Institutionalizing fire safety in making land use and development decisions
Marie-Annette Johnson; Marc Mullenix
1995-01-01
Because of three major wildland fires in the past 5 years along the Front Range of the Boulder County area in Colorado, current and potential residents should be told of steps that can reduce the risks of these fire hazards. The Wildfire Hazard Identification and Mitigation System (WHIMS) is used by the county and city to assist in the identification and mitigation of...
Kenneth L. Clark; Nicholas Skowronski; John Hom; Matthew Duveneck; Yude Pan; Stephen Van Tuyl; Jason Cole; Matthew Patterson; Stephen Maurer
2009-01-01
Our goal is to assist the New Jersey Forest Fire Service and federal wildland fire managers in the New Jersey Pine Barrens evaluate where and when to conduct hazardous fuel reduction treatments. We used remotely sensed LIDAR (Light Detection and Ranging System) data and field sampling to estimate fuel loads and consumption during prescribed fire treatments. This...
Survival analysis and classification methods for forest fire size
2018-01-01
Factors affecting wildland-fire size distribution include weather, fuels, and fire suppression activities. We present a novel application of survival analysis to quantify the effects of these factors on a sample of sizes of lightning-caused fires from Alberta, Canada. Two events were observed for each fire: the size at initial assessment (by the first fire fighters to arrive at the scene) and the size at “being held” (a state when no further increase in size is expected). We developed a statistical classifier to try to predict cases where there will be a growth in fire size (i.e., the size at “being held” exceeds the size at initial assessment). Logistic regression was preferred over two alternative classifiers, with covariates consistent with similar past analyses. We conducted survival analysis on the group of fires exhibiting a size increase. A screening process selected three covariates: an index of fire weather at the day the fire started, the fuel type burning at initial assessment, and a factor for the type and capabilities of the method of initial attack. The Cox proportional hazards model performed better than three accelerated failure time alternatives. Both fire weather and fuel type were highly significant, with effects consistent with known fire behaviour. The effects of initial attack method were not statistically significant, but did suggest a reverse causality that could arise if fire management agencies were to dispatch resources based on a-priori assessment of fire growth potentials. We discuss how a more sophisticated analysis of larger data sets could produce unbiased estimates of fire suppression effect under such circumstances. PMID:29320497
Survival analysis and classification methods for forest fire size.
Tremblay, Pier-Olivier; Duchesne, Thierry; Cumming, Steven G
2018-01-01
Factors affecting wildland-fire size distribution include weather, fuels, and fire suppression activities. We present a novel application of survival analysis to quantify the effects of these factors on a sample of sizes of lightning-caused fires from Alberta, Canada. Two events were observed for each fire: the size at initial assessment (by the first fire fighters to arrive at the scene) and the size at "being held" (a state when no further increase in size is expected). We developed a statistical classifier to try to predict cases where there will be a growth in fire size (i.e., the size at "being held" exceeds the size at initial assessment). Logistic regression was preferred over two alternative classifiers, with covariates consistent with similar past analyses. We conducted survival analysis on the group of fires exhibiting a size increase. A screening process selected three covariates: an index of fire weather at the day the fire started, the fuel type burning at initial assessment, and a factor for the type and capabilities of the method of initial attack. The Cox proportional hazards model performed better than three accelerated failure time alternatives. Both fire weather and fuel type were highly significant, with effects consistent with known fire behaviour. The effects of initial attack method were not statistically significant, but did suggest a reverse causality that could arise if fire management agencies were to dispatch resources based on a-priori assessment of fire growth potentials. We discuss how a more sophisticated analysis of larger data sets could produce unbiased estimates of fire suppression effect under such circumstances.
Fire hazard analysis for Plutonium Finishing Plant complex
DOE Office of Scientific and Technical Information (OSTI.GOV)
MCKINNIS, D.L.
1999-02-23
A fire hazards analysis (FHA) was performed for the Plutonium Finishing Plant (PFP) Complex at the Department of Energy (DOE) Hanford site. The scope of the FHA focuses on the nuclear facilities/structures in the Complex. The analysis was conducted in accordance with RLID 5480.7, [DOE Directive RLID 5480.7, 1/17/94] and DOE Order 5480.7A, ''Fire Protection'' [DOE Order 5480.7A, 2/17/93] and addresses each of the sixteen principle elements outlined in paragraph 9.a(3) of the Order. The elements are addressed in terms of the fire protection objectives stated in paragraph 4 of DOE 5480.7A. In addition, the FHA also complies with WHC-CM-4-41,more » Fire Protection Program Manual, Section 3.4 [1994] and WHC-SD-GN-FHA-30001, Rev. 0 [WHC, 1994]. Objectives of the FHA are to determine: (1) the fire hazards that expose the PFP facilities, or that are inherent in the building operations, (2) the adequacy of the fire safety features currently located in the PFP Complex, and (3) the degree of compliance of the facility with specific fire safety provisions in DOE orders, related engineering codes, and standards.« less
Gordon, Christopher E; Price, Owen F; Tasker, Elizabeth M; Denham, Andrew J
2017-01-01
High severity wildfires pose threats to human assets, but are also perceived to impact vegetation communities because a small number of species may become dominant immediately after fire. However there are considerable gaps in our knowledge about species-specific responses of plants to different fire severities, and how this influences fuel hazard in the short and long-term. Here we conduct a floristic survey at sites before and two years after a wildfire of unprecedented size and severity in the Warrumbungle National Park (Australia) to explore relationships between post-fire growth of a fire responsive shrub genera (Acacia), total mid-story vegetation cover, fire severity and fuel hazard. We then survey 129 plots surrounding the park to assess relationships between mid-story vegetation cover and time-since-fire. Acacia species richness and cover were 2.3 and 4.3 times greater at plots after than before the fire. However the same common dominant species were present throughout the study. Mid-story vegetation cover was 1.5 times greater after than before the wildfire, and Acacia species contribution to mid-story cover increased from 10 to 40%. Acacia species richness was not affected by fire severity, however strong positive associations were observed between Acacia and total mid-story vegetation cover and severity. Our analysis of mid-story vegetation recovery showed that cover was similarly high between 2 and 30years post-fire, then decreased until 52years. Collectively, our results suggest that Acacia species are extremely resilient to high severity wildfire and drive short to mid-term increases in fuel hazard. Our results are discussed in relation to fire regime management from the twin perspectives of conserving biodiversity and mitigating human losses due to wildfire. Copyright © 2016 Elsevier B.V. All rights reserved.
Development of Subscale Fast Cookoff Test (PREPRINT)
2006-09-21
The hazards classification procedures have been harmonized with both the UN Test and Criteria Manual for UN Series 1...aimed at the development of a sub-scale alternate test protocol to the external fire test currently required for final hazards classification (HC...external fire test currently required for final hazards classification (HC) of an ordnance system. The specific goal of this part of the task was
Uncertainties in predicting debris flow hazards following wildfire [Chapter 19
Kevin D. Hyde; Karin Riley; Cathelijne Stoof
2017-01-01
Wildfire increases the probability of debris flows posing hazardous conditions where valuesâatârisk exist downstream of burned areas. Conditions and processes leading to postfire debris flows usually follow a general sequence defined here as the postfire debris flow hazard cascade: biophysical setting, fire processes, fire effects, rainfall, debris flow, and valuesâatâ...
Rhonda Mazza
2008-01-01
The fire hazard in many western forests is unacceptably high, posing risks to human health and property, wildlife habitat, and air and water quality. Cost is an inhibiting factor for reducing hazardous fuel, given the amount of acreage needing treatment. Thinning overly dense forests is one way to reduce fuel loads. Much of the product removed during these treatments...
Safety issues of high-concentrated hydrogen peroxide production used as rocket propellant
NASA Astrophysics Data System (ADS)
Romantsova, O. V.; Ulybin, V. B.
2015-04-01
The article dwells on the possibility of production of high-concentrated hydrogen peroxide with the Russian technology of isopropyl alcohol autoxidation. Analysis of fire/explosion hazards and reasons of insufficient quality is conducted for the technology. Modified technology is shown. Non-standard fire/explosion characteristics required for integrated fire/explosion hazards rating for modified hydrogen peroxide production based on the autoxidation of isopropyl alcohol are defined.
Fire hazard reduction of hollow glass microspheres in thermoplastic polyurethane composites.
Jiao, Chuanmei; Wang, Hongzhi; Li, Shaoxiang; Chen, Xilei
2017-06-15
Nowadays, reducing the fire hazard of thermoplastic polyurethane (TPU) is an important research direction in the fields of fire safety materials. In this article, hollow glass microsphere (HGM) was used to reduce the fire hazard of TPU in combustion process. The fire characteristics including smoke and heat production of TPU composites were evaluated using smoke density test (SDT) and cone calorimeter test (CCT). And the thermal decomposition and flammable properties were further studied using thermogravimetric analysis/infrared spectrometry (TG-IR) and limiting oxygen index (LOI), etc. The SDT results showed that the luminous flux (LF) of TPU4 containing 2.00wt% HGM was up to 24% at the end of test without flame, which is much higher than that of TPU0 (5%). And, the CCT results indicated that 2.00wt% HGM could make the total smoke release (TSR) decrease from 1019m 2 /m 2 (TPU0) to 757m 2 /m 2 (TPU4), reduced by 26%. The TG-IR results confirmed that HGM could improve the thermal stability of composites and reduce the production of some toxic gases. The above results illustrated HGM had a good prospect in reducing the fire hazard for TPU. Copyright © 2017 Elsevier B.V. All rights reserved.
Wildfire spread, hazard and exposure metric raster grids for central Catalonia.
Alcasena, Fermín J; Ager, Alan A; Salis, Michele; Day, Michelle A; Vega-Garcia, Cristina
2018-04-01
We provide 40 m resolution wildfire spread, hazard and exposure metric raster grids for the 0.13 million ha fire-prone Bages County in central Catalonia (northeastern Spain) corresponding to node influence grid (NIG), crown fraction burned (CFB) and fire transmission to residential houses (TR). Fire spread and behavior data (NIG, CFB and fire perimeters) were generated with fire simulation modeling considering wildfire season extreme fire weather conditions (97 th percentile). Moreover, CFB was also generated for prescribed fire (Rx) mild weather conditions. The TR smoothed grid was obtained with a geospatial analysis considering large fire perimeters and individual residential structures located within the study area. We made these raster grids available to assist in the optimization of wildfire risk management plans within the study area and to help mitigate potential losses from catastrophic events.
Firing a Weapon and Killing In Combat Are Associated with Suicidal Ideation in OEF/OIF Veterans
Tripp, Jessica C.; McDevitt-Murphy, Meghan E.; Henschel, Aisling V.
2016-01-01
Objective Combat veterans are at risk for several adverse outcomes such as posttraumatic stress disorder (PTSD), depression, hazardous alcohol use, and most critically, suicidal behaviors. The high rate of suicide in veterans has been understood as a correlate of PTSD and depression, but it is possible that certain specific types of combat experiences may lead to suicidal behaviors. Acts committed by the veteran in the context of war such as killing may evoke a “moral injury,” which leads to thoughts of ending one’s life. Method The present exploratory research examined relationships between combat experiences and suicidal ideation (SI) and PTSD in a sample of 68 OEF/OIF veterans (91% male, mean age = 32.31 years) who had screened positive for alcohol misuse. We examined firing a weapon/killing in combat (Firing/Killing) and killing in combat (Killing) alone as predictors of (SI) and PTSD severity in both the full sample, and in analyses that examined men only. Results Firing/Killing were associated with SI for the full sample and men only, and Killing showed a trend towards significance in predicting SI. Hierarchical regression analyses suggested that Firing/Killing did not predict PTSD for the full sample or men only, but Killing was predictive of PTSD for both samples. Conclusions These results indicate that there may be differences in Firing/Killing and Killing alone in OEF/OIF veterans who screened positive for alcohol misuse. Thorough screening of combat experiences and addressing moral injury in returning combat veterans may help reduce high rates of suicide and PTSD. PMID:26460495
NASA Astrophysics Data System (ADS)
Tutak, Magdalena; Brodny, Jarosław
2018-01-01
Hazard of endogenous fires is one of the basic and common presented occupational safety hazards in coal mine in Poland and in the world. This hazard means possibility of coal self-ignition as the result of its self-heating process in mining heading or its surrounding. In underground coal-mining during ventilating of operating longwalls takes place migration of parts of airflow to goaf with caving. In a case when in these goaf a coal susceptible to self-ignition occurs, then the airflow through these goaf may influence on formation of favorable conditions for coal oxidation and subsequently to its self-heating and self-ignition. Endogenous fire formed in such conditions can pose a serious hazards for the crew and for continuity of operation of mining plant. From the practical point of view a very significant meaning has determination of the zone in the goaf with caving, in which necessary conditions for occurence of endogenous fire are fulfilled. In the real conditions determination of such a zone is practically impossible. The main aim of the analysis was to determine the impact of type of the roof rocks forming the goaf on the location and range of endogenous fires particular hazard zone by in these goaf. For determined mining-geological conditions, the critical value of velocity of airflow and oxygen concentration in goaf, conditioning initiation of coal oxidation process were determined.
Influence of long-term storage on fire hazard properties of metal nanopowders
NASA Astrophysics Data System (ADS)
Kyrmakova, O. S.; Sechin, A. I.; Nazarenko, O. B.
2017-08-01
The production and application of nanomaterials is rapidly expanding. Therefore the problem of their properties change during long-term storage becomes essential. The properties of metal nanopowders after long-term storage under ambient conditions were studied and the results are presented in this work. The aluminum, iron, zinc, and copper nanopowders produced by the method of electrical explosion of wires were investigated in this work. The investigation was carried out by X-ray and thermal analysis. The estimation of the flame propagation velocity in the bulk layer of nanopowders was carried out. The characteristics of the nanopowders of nanometals studied are given in terms of their fire hazard. The results can be used for diagnostic of fire hazard of nanomaterials and protection of the enterprises against fire and explosion.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-17
... lead to ignition of fuel vapor, creating a fire and explosion hazard resulting in injury, and damage to... ignition of fuel vapor, creating a fire and explosion hazard resulting in injury, and damage to the APU and...
75 FR 44275 - Hazardous Fire Risk Reduction, East Bay Hills, CA
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-28
... DEPARTMENT OF HOMELAND SECURITY Federal Emergency Management Agency [Docket ID FEMA-2010-0037] Hazardous Fire Risk Reduction, East Bay Hills, CA AGENCY: Federal Emergency Management Agency, DHS. ACTION: Notice of extension of comment period. SUMMARY: The Federal Emergency Management Agency (FEMA) is...
Code of Federal Regulations, 2011 CFR
2011-07-01
... ACCIDENT PREVENTION PROVISIONS Program 3 Prevention Program § 68.87 Contractors. (a) Application. This... known potential fire, explosion, or toxic release hazards related to the contractor's work and the... instructed in the known potential fire, explosion, or toxic release hazards related to his/her job and the...
Code of Federal Regulations, 2012 CFR
2012-07-01
... ACCIDENT PREVENTION PROVISIONS Program 3 Prevention Program § 68.87 Contractors. (a) Application. This... known potential fire, explosion, or toxic release hazards related to the contractor's work and the... instructed in the known potential fire, explosion, or toxic release hazards related to his/her job and the...
Code of Federal Regulations, 2014 CFR
2014-07-01
... ACCIDENT PREVENTION PROVISIONS Program 3 Prevention Program § 68.87 Contractors. (a) Application. This... known potential fire, explosion, or toxic release hazards related to the contractor's work and the... instructed in the known potential fire, explosion, or toxic release hazards related to his/her job and the...
Code of Federal Regulations, 2013 CFR
2013-07-01
... ACCIDENT PREVENTION PROVISIONS Program 3 Prevention Program § 68.87 Contractors. (a) Application. This... known potential fire, explosion, or toxic release hazards related to the contractor's work and the... instructed in the known potential fire, explosion, or toxic release hazards related to his/her job and the...
ERIC Educational Resources Information Center
Needham, Dorothy
1977-01-01
National Fire Protection Week is a perfect time for launching a fire safety learning center. The activities described here are intended to help children recognize fire hazards in their homes, play areas and public buildings; learn how to act intelligently in fire emergencies; be able to share their knowledge of fire safety with others and…
Vehicle fires and fire safety in tunnels
DOT National Transportation Integrated Search
2002-09-20
Tunnels present what is arguably the most hazardous environment, from the point of view of fire safety, that members of the public ever experience. The fire safety design of tunnels is carried out by tunnel engineers on the basis of a potential fire ...
Christopher J. Fettig; Joel D. McMillin; John. A. Anhold; Shakeeb M. Hamud; Steven J. Seybold; Robert R. Borys
2008-01-01
(Please note, this is an abstract only) Selective logging, fire suppression, forest succession, and climatic changes have resulted in high fire hazards over large areas of the western United States. Federal and state hazardous fuel reduction programs have increased accordingly to reduce the risk, extent and severity of these events, particularly in the wildland urban...
Liu, Xiaopeng; Lessner, Lawrence
2012-01-01
Background: Air pollution is known to cause respiratory disease. Unlike motor vehicle sources, fuel-fired power plants are stationary. Objective: Using hospitalization data, we examined whether living near a fuel-fired power plant increases the likelihood of hospitalization for respiratory disease. Methods: Rates of hospitalization for asthma, acute respiratory infection (ARI), and chronic obstructive pulmonary disease (COPD) were estimated using hospitalization data for 1993–2008 from New York State in relation to data for residences near fuel-fired power plants. We also explored data for residential proximity to hazardous waste sites. Results: After adjusting for age, sex, race, median household income, and rural/urban residence, there were significant 11%, 15%, and 17% increases in estimated rates of hospitalization for asthma, ARI, and COPD, respectively, among individuals > 10 years of age living in a ZIP code containing a fuel-fired power plant compared with one that had no power plant. Living in a ZIP code with a fuel-fired power plant was not significantly associated with hospitalization for asthma or ARI among children < 10 years of age. Living in a ZIP code with a hazardous waste site was associated with hospitalization for all outcomes in both age groups, and joint effect estimates were approximately additive for living in a ZIP code that contained a fuel-fired power plant and a hazardous waste site. Conclusions: Our results are consistent with the hypothesis that exposure to air pollution from fuel-fired power plants and volatile compounds coming from hazardous waste sites increases the risk of hospitalization for respiratory diseases. PMID:22370087
Rocky Mountain Research Station USDA Forest Service
2005-01-01
The Guide to Fuel Treatments analyzes a range of potential silvicultural thinnings and surface fuel treatments for 25 representative dry-forest stands in the Western United States. The guide provides quantitative guidelines and visualization for treatment based on scientific principles identified for reducing potential crown fires. This fact sheet identifies the...
The effects of prescribed burning on fire hazard in the chaparral: toward a new conceptual synthesis
Anthony T. Dunn
1989-01-01
Prescribed burning for fire hazard reduction in the chaparral is predicated on the belief that young fuels (20 years old and less) are highly resistant to burning. To test this belief, a data base search of large fires in San Diego County between 1940 and 1985 was conducted to locate reburns of young chaparral fuels greater than 1000 acres (400 ha) in extent. Of the...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-02
... Electric Utility Steam Generating Units and Standards of Performance for Fossil-Fuel-Fired Electric Utility...-fired Electric Utility Steam Generating Units and Standards of Performance for Fossil-Fuel-Fired...
Sleep Quantity and Quality of Ontario Wildland Firefighters Across a Low-Hazard Fire Season
McGillis, Zachary; Dorman, Sandra C.; Robertson, Ayden; Larivière, Michel; Leduc, Caleb; Eger, Tammy; Oddson, Bruce E.; Larivière, Céline
2017-01-01
Objective: The aim of the study was to assess the sleep quality, quantity, and fatigue levels of Canadian wildland firefighters while on deployment. Methods: Objective and subjective sleep and fatigue measures were collected using actigraphy and questionnaires during non-fire (Base) and fire (Initial Attack and Project) deployments. Results: Suboptimal sleep quality and quantity were more frequently observed during high-intensity, Initial Attack fire deployments. Suboptimal sleep was also exhibited during non-fire (Base) work periods, which increases the risk of prefire deployment sleep debt. Self-reported, morning fatigue scores were low-to-moderate and highest for Initial Attack fire deployments. Conclusions: The study highlights the incidence of suboptimal sleep patterns in wildland firefighters during non-fire and fire suppression work periods. These results have implications for the health and safety practices of firefighters given the link between sleep and fatigue, in a characteristically hazardous occupation. PMID:29216017
Shie, Ruei-Hao; Chan, Chang-Chuan
2013-10-15
The air monitors used by most regulatory authorities are designed to track the daily emissions of conventional pollutants and are not well suited for measuring hazardous air pollutants that are released from accidents such as refinery fires. By applying a wide variety of air-monitoring systems, including on-line Fourier transform infrared spectroscopy, gas chromatography with a flame ionization detector, and off-line gas chromatography-mass spectrometry for measuring hazardous air pollutants during and after a fire at a petrochemical complex in central Taiwan on May 12, 2011, we were able to detect significantly higher levels of combustion-related gaseous and particulate pollutants, refinery-related hydrocarbons, and chlorinated hydrocarbons, such as 1,2-dichloroethane, vinyl chloride monomer, and dichloromethane, inside the complex and 10 km downwind from the fire than those measured during the normal operation periods. Both back trajectories and dispersion models further confirmed that high levels of hazardous air pollutants in the neighboring communities were carried by air mass flown from the 22 plants that were shut down by the fire. This study demonstrates that hazardous air pollutants from industrial accidents can successfully be identified and traced back to their emission sources by applying a timely and comprehensive air-monitoring campaign and back trajectory air flow models. Copyright © 2013 The Authors. Published by Elsevier B.V. All rights reserved.
Current status and future needs of the BehavePlus Fire Modeling System
Patricia L. Andrews
2014-01-01
The BehavePlus Fire Modeling System is among the most widely used systems for wildland fire prediction. It is designed for use in a range of tasks including wildfire behaviour prediction, prescribed fire planning, fire investigation, fuel hazard assessment, fire model understanding, communication and research. BehavePlus is based on mathematical models for fire...
Moritz, Max A.; Keeley, Jon E.; Johnson, Edward A.; Schaffner, Andrew A.
2004-01-01
This year's catastrophic wildfires in southern California highlight the need for effective planning and management for fire-prone landscapes. Fire frequency analysis of several hundred wildfires over a broad expanse of California shrublands reveals that there is generally not, as is commonly assumed, a strong relationship between fuel age and fire probabilities. Instead, the hazard of burning in most locations increases only moderately with time since the last fire, and a marked age effect of fuels is observed only in limited areas. Results indicate a serious need for a re-evaluation of current fire management and policy, which is based largely on eliminating older stands of shrubland vegetation. In many shrubland ecosystems exposed to extreme fire weather, large and intense wildfires may need to be factored in as inevitable events.
Fire! Fire Prevention and Safety: A Teacher's Handbook.
ERIC Educational Resources Information Center
New York City Board of Education, Brooklyn, NY. Div. of Educational Planning and Support.
In this curriculum guide, guidelines for teaching children about fire safety and related topics and activities representing an interdisciplinary approach to fire safety are outlined. Major fire hazards and methods of dealing with them are described. Possible sites for field trips and films relating to fire are listed. The rules of the New York…
Phytoremediation of Pb in the sediment of a mangrove ecosystem
USDA-ARS?s Scientific Manuscript database
Lead (Pb) is a naturally occurring element that poses environmental risks and hazards if present at elevated concentration. It is being released into the environment because of industrial uses, combustion of fossils fuels and from coal-fired power plants. Coal-fired power plants can discharge hazard...
40 CFR 266.102 - Permit standards for burners.
Code of Federal Regulations, 2013 CFR
2013-07-01
... subpart G (Closure and post-closure), §§ 264.111-264.115; (viii) In subpart H (Financial requirements... prescribed in paragraph (e)(6) of this section; (C) Appropriate controls of the hazardous waste firing system...; (C) Appropriate controls on operation and maintenance of the hazardous waste firing system and any...
40 CFR 266.102 - Permit standards for burners.
Code of Federal Regulations, 2012 CFR
2012-07-01
... subpart G (Closure and post-closure), §§ 264.111-264.115; (viii) In subpart H (Financial requirements... prescribed in paragraph (e)(6) of this section; (C) Appropriate controls of the hazardous waste firing system...; (C) Appropriate controls on operation and maintenance of the hazardous waste firing system and any...
40 CFR 266.102 - Permit standards for burners.
Code of Federal Regulations, 2011 CFR
2011-07-01
... subpart G (Closure and post-closure), §§ 264.111-264.115; (viii) In subpart H (Financial requirements... prescribed in paragraph (e)(6) of this section; (C) Appropriate controls of the hazardous waste firing system...; (C) Appropriate controls on operation and maintenance of the hazardous waste firing system and any...
40 CFR 266.102 - Permit standards for burners.
Code of Federal Regulations, 2014 CFR
2014-07-01
... subpart G (Closure and post-closure), §§ 264.111-264.115; (viii) In subpart H (Financial requirements... prescribed in paragraph (e)(6) of this section; (C) Appropriate controls of the hazardous waste firing system...; (C) Appropriate controls on operation and maintenance of the hazardous waste firing system and any...
40 CFR 266.102 - Permit standards for burners.
Code of Federal Regulations, 2010 CFR
2010-07-01
... subpart G (Closure and post-closure), §§ 264.111-264.115; (viii) In subpart H (Financial requirements... prescribed in paragraph (e)(6) of this section; (C) Appropriate controls of the hazardous waste firing system...; (C) Appropriate controls on operation and maintenance of the hazardous waste firing system and any...
16 CFR 1500.15 - Labeling of fire extinguishers.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Labeling of fire extinguishers. 1500.15 Section 1500.15 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT...)(1), the signal word “Danger” and the statement of hazard “Poisonous gases formed when used to...
NASA Astrophysics Data System (ADS)
Vilain, J.
Approaches to major hazard assessment and prediction are reviewed. Source term: (phenomenology/modeling of release, influence on early stages of dispersion); dispersion (atmospheric advection, diffusion and deposition, emphasis on dense/cold gases); combustion (flammable clouds and mists covering flash fires, deflagration, transition to detonation; mostly unconfined/partly confined situations); blast formation, propagation, interaction with structures; catastrophic fires (pool fires, torches and fireballs; highly reactive substances) runaway reactions; features of more general interest; toxic substances, excluding toxicology; and dust explosions (phenomenology and protective measures) are discussed.
Is Fire Safety a Burning Issue for Your Home?
ERIC Educational Resources Information Center
Haines, Jamie E.
1986-01-01
Families can take an active role in protecting their homes and themselves from fire by: (1) keeping their homes free of fire hazards; (2) installing, testing, and maintaining smoke detectors; and (3) developing a fire escape plan. (DF)
Fire Technology Abstracts, volume 4, issue 1, August, 1981
NASA Astrophysics Data System (ADS)
Holtschlag, L. J.; Kuvshinoff, B. W.; Jernigan, J. B.
This bibliography contains over 400 citations with abstracts addressing various aspects of fire technology. Subjects cover the dynamics of fire, behavior and properties of materials, fire modeling and test burns, fire protection, fire safety, fire service organization, apparatus and equipment, fire prevention, suppression, planning, human behavior, medical problems, codes and standards, hazard identification, safe handling of materials, insurance, economics of loss and prevention, and more.
[Research progress in post-fire debris flow].
Di, Xue-ying; Tao, Yu-zhu
2013-08-01
The occurrence of the secondary disasters of forest fire has significant impacts on the environment quality and human health and safety. Post-fire debris flow is one of the most hazardous secondary disasters of forest fire. To understand the occurrence conditions of post-fire debris flow and to master its occurrence situation are the critical elements in post-fire hazard assessment. From the viewpoints of vegetation, precipitation threshold and debris flow material sources, this paper elaborated the impacts of forest fire on the debris flow, analyzed the geologic and geomorphic conditions, precipitation and slope condition that caused the post-fire debris flow as well as the primary mechanisms of debris-flow initiation caused by shallow landslide or surface runoff, and reviewed the research progress in the prediction and forecast of post-fire debris flow and the related control measures. In the future research, four aspects to be focused on were proposed, i. e., the quantification of the relationships between the fire behaviors and environmental factors and the post-fire debris flow, the quantitative research on the post-fire debris flow initiation and movement processes, the mechanistic model of post-fire debris flow, and the rapid and efficient control countermeasures of post-fire debris flow.
Fire and worker health and safety: an introduction to the special issue.
Campbell, Richard; Levenstein, Charles
2015-02-01
One century ago, the landmark fire at the Triangle Shirtwaist Factory in New York City claimed the lives of 146 garment workers and helped spur the adoption of fire safety measures and laws targeting dangerous working conditions. Since that time, continuing advances have been made to address the threat of fire-in workplace fire safety practices and regulations, in training and safety requirements for firefighters and first responders, and in hazard communication laws that enhance disaster planning and response. Recent high profile events, including the West, Texas fertilizer plant explosion, derailments of fuel cargo trains, and garment factory fires in Bangladesh, have brought renewed attention to fire as a workplace health and safety issue and to the unevenness of safety standards and regulatory enforcement, in the United States as well as internationally. In this article, we provide an overview of fire as a workplace health and safety hazard and an introduction to the essays included in this special issue of New Solutions on fire and work. © 2015 SAGE Publications.
Fire Inspection Guide for Schools.
ERIC Educational Resources Information Center
Virginia State Corp. Commission, Richmond.
A functional explanation of the "School Fire Prevention Inspection Form" is provided for use by local school and fire department personnel in the Virginia School Fire Prevention Inspection Program. Many helpful suggestions are made for safeguarding occupants of public school buildings from fire hazards. Items discussed are--(1) exit doors, (2)…
Teach Children Fire Will Burn.
ERIC Educational Resources Information Center
Children's Bureau (DHEW), Washington, DC.
This handbook, addressed to parents and others responsible for the safety of children, presents information on fire hazards, prevention and protection. Emphasizing an early start to fire safety training, it outlines the basic facts of fire safety education, listing the most frequent causes of fire and suggesting the organization of a Family Fire…
Fire Protection in Educational Occupancies.
ERIC Educational Resources Information Center
Gervais, Romeo P.
2000-01-01
Discusses the origins of school fires and the components of the fire protection code called the Life Safety Code (LSC). Three of the following LSC requirements are described: means of egress; protection from hazards; and fire suppression and alarm systems. Information on who starts fires is highlighted along with preventive measures. (GR)
29 CFR 1926.151 - Fire prevention.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 29 Labor 8 2013-07-01 2013-07-01 false Fire prevention. 1926.151 Section 1926.151 Labor... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Fire Protection and Prevention § 1926.151 Fire... at or in the vicinity of operations which constitute a fire hazard, and shall be conspicuously posted...
29 CFR 1926.151 - Fire prevention.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 29 Labor 8 2014-07-01 2014-07-01 false Fire prevention. 1926.151 Section 1926.151 Labor... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Fire Protection and Prevention § 1926.151 Fire... at or in the vicinity of operations which constitute a fire hazard, and shall be conspicuously posted...
29 CFR 1926.151 - Fire prevention.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 29 Labor 8 2012-07-01 2012-07-01 false Fire prevention. 1926.151 Section 1926.151 Labor... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Fire Protection and Prevention § 1926.151 Fire... at or in the vicinity of operations which constitute a fire hazard, and shall be conspicuously posted...
Gaseous emissions and toxic hazards associated with plastics in fire situations: A literature review
NASA Technical Reports Server (NTRS)
Junod, T. L.
1976-01-01
The hazards of plastics in fire situations, the gases emitted, the factors influencing the nature of these emissions, the characteristics of toxic gases, and the results of laboratory studies, are discussed. The literature pertaining to the pyrolysis and oxidation of plastics was reviewed. An effort was made to define the state of the art for determining the toxic gases emitted by plastics under fire conditions. Recommendations are made and research needs defined as a result of this review.
Rocky Mountain Research Station USDA Forest Service
2004-01-01
Within the past 10 years, breakthrough research has identified factors that are most important for effectively communicating about wildland fire hazards. This fact sheet discusses seven "Laws" of effective public communication that should be considered in any state-of-the-art education campaign.
Financial analysis of fuel treatments.
Fight; Roger D.; R. James Barbour
2005-01-01
The purpose of this paper is to provide information and discussion that will be helpful in promoting thoughtful design of fire hazard reduction treatments to meet the full range of management objectives. Thoughtful design requires an understanding of the costs and potential revenues of applying variations of fire hazard reduction treatments in a wide range of stand...
NASA Technical Reports Server (NTRS)
Zanelli, C.; Philbrick, S.; Beretta, G.
1986-01-01
Besides describing the experiments conducted to develop a nonflammable cable, this article discusses several considerations regarding other hazards which might result from cable fires, particularly the toxicity and opacity of the fumes emitted by the burning cable. In addition, this article examines the effects of using the Oxygen Index as a gauge of quality control during manufacture.
A new tool for fire managers: An electronic duff moisture meter
Peter R. Robichaud; Jim Bilskie
2004-01-01
Prescribed fires are increasingly being used to reduce hazardous fuels, a major objective of the National Fire Plan. Despite advancing technology and ever-improving models, fire managers still find it challenging to determine the right time for a prescribed burn.
Dale G. Brockway; Kenneth W Outcalt
2005-01-01
The principal objective is to quantify the responses of the understory plant community to fire and fire surrogate treatments, specifically plant species composition, foliar cover, species richness, diversity, and evenness changes resulting from (1) fire exclusion in the untreated control, (2) prescribed fire, (3) thinning, (4) thinning plus prescribed fire, and (5)...
Butsic, Van; Syphard, Alexandra D.; Keeley, Jon E.; Bar-Massada, Avi
2017-01-01
The purchase of private land for conservation purposes is a common way to prevent the exploitation of sensitive ecological areas. However, private land conservation can also provide other benefits, one of these being natural hazard reduction. Here, we investigated the impacts of private land conservation on fire risk to homes in San Diego County, California. We coupled an econometric land use change model with a model that estimates the probability of house loss due to fire in order to compare fire risk at the county and municipality scale under alternative private land purchasing schemes and over a 20 year time horizon. We found that conservation purchases could reduce fire risk on this landscape, and the amount of risk reduction was related to the targeting approach used to choose which parcels were conserved. Conservation land purchases that targeted parcels designated as high fire hazard resulted in lower fire risk to homes than purchases that targeted low costs or high likelihood to subdivide. This result was driven by (1) preventing home placement in fire prone areas and (2) taking land off the market, and hence increasing development densities in other areas. These results raise the possibility that resource conservation and fire hazard reduction may benefit from combining efforts. With adequate planning, future conservation purchases could have synergistic effects beyond just protecting ecologically sensitive areas.
Wildfire disturbance, erosion and sedimentation risks following the Waldo Canyon Fire in Colorado
NASA Astrophysics Data System (ADS)
Flint, K.; Kinoshita, A. M.; Chin, A.; Florsheim, J. L.; Nourbakhshbeidokhti, S.
2016-12-01
Wildfire is a landscape-scale disturbance that causes abrupt changes to hydrological responses and sediment flux during subsequent storms. Burning hillslope vegetation during wildfires induces changes to sediment supply and stream flow magnitude. Altered post-fire processes such as channel erosion and sedimentation or flooding enhance downstream hazards that may threaten human populations and physical aquatic habitat over various time scales. Using data from a small drainage basin (Williams Canyon, 4.7 km2) in the Colorado front range burned by the 2012 Waldo Fire as a case study, we investigate post-fire recovery and assess changes in fire-related risks to downstream areas. Our local ground-based precipitation, field measurements, terrestrial Light Detection and Ranging (LiDAR) scanning together with satellite-based remote sensing data (i.e. Landsat) provide a basis for time series analyses of reach-scale erosion and sedimentation response to rainfall patterns as vegetation patterns change following the wildfire. As a first step in quantifying the likelihood and consequences of specific risk scenarios, we examine changes in the combined probability of storm flows and post-fire erosion and sedimentation as vegetation recovers within the study watershed. We explore possible feedbacks and thresholds related to vegetation-hydrology-sediment interactions following wildfire under changing climate regimes. This information is needed to assist in post-fire management to promote sustainability of wildland fluvial systems.
Renjith, V R; Madhu, G; Nayagam, V Lakshmana Gomathi; Bhasi, A B
2010-11-15
The hazards associated with major accident hazard (MAH) industries are fire, explosion and toxic gas releases. Of these, toxic gas release is the worst as it has the potential to cause extensive fatalities. Qualitative and quantitative hazard analyses are essential for the identification and quantification of these hazards related to chemical industries. Fault tree analysis (FTA) is an established technique in hazard identification. This technique has the advantage of being both qualitative and quantitative, if the probabilities and frequencies of the basic events are known. This paper outlines the estimation of the probability of release of chlorine from storage and filling facility of chlor-alkali industry using FTA. An attempt has also been made to arrive at the probability of chlorine release using expert elicitation and proven fuzzy logic technique for Indian conditions. Sensitivity analysis has been done to evaluate the percentage contribution of each basic event that could lead to chlorine release. Two-dimensional fuzzy fault tree analysis (TDFFTA) has been proposed for balancing the hesitation factor involved in expert elicitation. Copyright © 2010 Elsevier B.V. All rights reserved.
Fire hazard considerations for composites in vehicle design
NASA Technical Reports Server (NTRS)
Gordon, Rex B.
1994-01-01
Military ground vehicles fires are a significant cause of system loss, equipment damage, and crew injury in both combat and non-combat situations. During combat, the ability to successfully fight an internal fire, without losing fighting and mobility capabilities, is often the key to crew survival and mission success. In addition to enemy hits in combat, vehicle fires are initiated by electrical system failures, fuel line leaks, munitions mishaps and improper personnel actions. If not controlled, such fires can spread to other areas of the vehicle, causing extensive damage and the potential for personnel injury and death. The inherent fire safety characteristics (i.e. ignitability, compartments of these vehicles play a major roll in determining rather a newly started fire becomes a fizzle or a catastrophe. This paper addresses a systems approach to assuring optimum vehicle fire safety during the design phase of complex vehicle systems utilizing extensive uses of composites, plastic and related materials. It provides practical means for defining the potential fire hazard risks during a conceptual design phase, and criteria for the selection of composite materials based on its fire safety characteristics.
Self-organization, the cascade model, and natural hazards.
Turcotte, Donald L; Malamud, Bruce D; Guzzetti, Fausto; Reichenbach, Paola
2002-02-19
We consider the frequency-size statistics of two natural hazards, forest fires and landslides. Both appear to satisfy power-law (fractal) distributions to a good approximation under a wide variety of conditions. Two simple cellular-automata models have been proposed as analogs for this observed behavior, the forest fire model for forest fires and the sand pile model for landslides. The behavior of these models can be understood in terms of a self-similar inverse cascade. For the forest fire model the cascade consists of the coalescence of clusters of trees; for the sand pile model the cascade consists of the coalescence of metastable regions.
Self-organization, the cascade model, and natural hazards
Turcotte, Donald L.; Malamud, Bruce D.; Guzzetti, Fausto; Reichenbach, Paola
2002-01-01
We consider the frequency-size statistics of two natural hazards, forest fires and landslides. Both appear to satisfy power-law (fractal) distributions to a good approximation under a wide variety of conditions. Two simple cellular-automata models have been proposed as analogs for this observed behavior, the forest fire model for forest fires and the sand pile model for landslides. The behavior of these models can be understood in terms of a self-similar inverse cascade. For the forest fire model the cascade consists of the coalescence of clusters of trees; for the sand pile model the cascade consists of the coalescence of metastable regions. PMID:11875206
NASA Astrophysics Data System (ADS)
Lindquist, Eric; Pierce, Jen; Wuerzer, Thomas; Glenn, Nancy; Dialani, Jijay; Gibble, Katie; Frazier, Tim; Strand, Eva
2015-04-01
The stages of planning for and responding to natural hazards, such as wildfires and related events, are often conducted as discrete (and often not connected) efforts. Disaster response often takes precedence, exhausting agency and stakeholder resources, and the planning stages are conducted by different agencies or entities with different and often competing agendas and jurisdictions. The result is that evaluation after a disaster can be minimal or even non-existent as resources are expended and interest moves on to the next event. Natural disasters and hazards, however, have a tendency to cascade and multiply: wildfires impact the vulnerability of hillslopes, for example, which may result in landslides, flooding and debris flows long after the initial event has occurred. Connecting decisions across multiple events and time scales is ignored, yet these connections could lead to better policy making at all stages of disaster risk reduction. Considering this situation, we present an adapted life cycle analysis (LCA) approach to examine fire-related hazards at the Wildland-Urban Interface in the American West. The LCHA focuses on the temporal integration of : 1) the 'pre-fire' set of physical conditions (e.g. fuel loads) and human conditions (e.g. hazard awareness), 2) the 'fire event', focusing on computational analysis of the communication patterns and responsibility for response to the event, and 3) the 'post-event' analysis of the landscape susceptibility to fire-related debris flows. The approach of the LCHA follows other models used by governmental agencies to prepare for disasters through 1) preparation and prevention, 2) response and 3) recovery. As an overlay are the diverse agencies and policies associated with these stages and their respective resource and management decisions over time. LCAs have evolved from a business-centric consideration of the environmental impact of a specific product over the products life. This approach takes several phases to end up with an assessment of the impact of the product on the environment over time and is being considered beyond the business and logistics communities in such areas as biodiversity and ecosystem impacts. From our perspective, we consider wildfire as the "product" and want to understand how it impacts the environment (spatially, temporally, across the bio-physical and social domains). Through development of this LCHA we adapt the LCA approach with a focus on the inputs (from fire and pre-fire efforts) outputs (from post fire conditions) and how they evolve and are responded to by the responsible agencies and stakeholders responsible. A Life Cycle Hazard Assessment (LCHA) approach extends and integrates the understanding of hazards over much longer periods of time than previously considered. The LCHA also provides an integrated platform for the necessary interdisciplinary approach to understanding decision and environmental change across the life cycle of the fire event. This presentation will discuss our theoretical and empirical framework for developing a longitudinal LCHA and contribute to the overall goals of the NH7.1 session.
Assessing high reliability practices in the wildland fire community
Anne E. Black; Kathleen Sutcliffe; Michelle Barton; Deirdre Dether
2008-01-01
The Office of Inspector General's 2006 audit of Forest Service fire management operations added yet another voice to the growing chorus calling on the Federal wildland fire community to get more fire on the ground (OIG 2006). The 1995 National Fire Plan and the 2001 Implementation Plan identify the critical role of wildland fire use in reducing hazardous fuels...
Space station internal environmental and safety concerns
NASA Technical Reports Server (NTRS)
Cole, Matthew B.
1987-01-01
Space station environmental and safety concerns, especially those involving fires, are discussed. Several types of space station modules and the particular hazards associated with each are briefly surveyed. A brief history of fire detection and suppression aboard spacecraft is given. Microgravity fire behavior, spacecraft fire detector systems, space station fire suppression equipment and procedures, and fire safety in hyperbaric chambers are discussed.
ERIC Educational Resources Information Center
Texas State Commission on Fire Protection, Austin.
This booklet comprises the seventh grade component of a series of curriculum guides on fire and burn prevention. Designed to meet the age-specific needs of seventh grade students, its objectives include: (1) practicing responsible decision-making regarding fire and burn hazards, including peer pressure related to fire risks; and (2) practicing…
Establishing a proactive safety and health risk management system in the fire service.
Poplin, Gerald S; Pollack, Keshia M; Griffin, Stephanie; Day-Nash, Virginia; Peate, Wayne F; Nied, Ed; Gulotta, John; Burgess, Jefferey L
2015-04-19
Formalized risk management (RM) is an internationally accepted process for reducing hazards in the workplace, with defined steps including hazard scoping, risk assessment, and implementation of controls, all within an iterative process. While required for all industry in the European Union and widely used elsewhere, the United States maintains a compliance-based regulatory structure, rather than one based on systematic, risk-based methodologies. Firefighting is a hazardous profession, with high injury, illness, and fatality rates compared with other occupations, and implementation of RM programs has the potential to greatly improve firefighter safety and health; however, no descriptions of RM implementation are in the peer-reviewed literature for the North American fire service. In this paper we describe the steps used to design and implement the RM process in a moderately-sized fire department, with particular focus on prioritizing and managing injury hazards during patient transport, fireground, and physical exercise procedures. Hazard scoping and formalized risk assessments are described, in addition to the identification of participatory-led injury control strategies. Process evaluation methods were conducted to primarily assess the feasibility of voluntarily instituting the RM approach within the fire service setting. The RM process was well accepted by the fire department and led to development of 45 hazard specific-interventions. Qualitative data documenting the implementation of the RM process revealed that participants emphasized the: value of the RM process, especially the participatory bottom-up approach; usefulness of the RM process for breaking down tasks to identify potential risks; and potential of RM for reducing firefighter injury. As implemented, this risk-based approach used to identify and manage occupational hazards and risks was successful and is deemed feasible for U.S. (and other) fire services. While several barriers and challenges do exist in the implementation of any intervention such as this, recommendations for adopting the process are provided. Additional work will be performed to determine the effectiveness of select controls strategies that were implemented; however participants throughout the organizational structure perceived the RM process to be of high utility while researchers also found the process improved the awareness and engagement in actively enhancing worker safety and health.
Nursing students practice primary fire prevention.
Lehna, Carlee; Todd, Julie A; Keller, Rachel; Presley, Lynn; Jackson, Jessica; Davis, Stephanie; Hockman, Kristi; Phillips-Payne, Charles; Sauer, Sarah; Wessemeier, Sarah
2013-09-01
The purpose of this project was to evaluate a standardized, interactive, home fire safety program for elementary school students. Senior baccalaureate nursing students in their pediatric clinical rotation taught burn prevention techniques using Hazard House, a model house filled with common household fire hazards (Hazard House, 2006, Ref. 1). Elementary school students were encouraged to identify the hazards and discuss ways in which the house could be made safer. Local firemen then briefly presented what to do if a fire occurred, how firemen may look during a rescue, and the importance of working smoke alarms in the home. A pretest-posttest design was used to examine the effectiveness of an educational intervention. The three groups of participants included 128 kindergarten students, 311 students in grades 1-2, and 61 students in grades 3-4. The tests and interventions were tailored appropriately for each age group. There was no difference in pre- and post-test scores for the students in kindergarten and grades 3-4 (p>0.05). However, there was a significant difference for students in grades 1-2 (p<0.001). It is important for nurses to assess for and teach about fire injury prevention to prevent potentially devastating irreversible injuries. The results suggest that the educational intervention was effective in improving the understanding of fire safety for students in grades 1-2. Future studies may need to include a larger sample of students for the other grades. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.
Comparative hazard evaluation of near-infrared diode lasers.
Marshall, W J
1994-05-01
Hazard evaluation methods from various laser protection standards differ when applied to extended-source, near-infrared lasers. By way of example, various hazard analyses are applied to laser training systems, which incorporate diode lasers, specifically those that assist in training military or law enforcement personnel in the proper use of weapons by simulating actual firing by the substitution of a beam of near-infrared energy for bullets. A correct hazard evaluation of these lasers is necessary since simulators are designed to be directed toward personnel during normal use. The differences among laser standards are most apparent when determining the hazard class of a laser. Hazard classification is based on a comparison of the potential exposures with the maximum permissible exposures in the 1986 and 1993 versions of the American National Standard for the Safe Use of Lasers, Z136.1, and the accessible emission limits of the federal laser product performance standard. Necessary safety design features of a particular system depend on the hazard class. The ANSI Z136.1-1993 standard provides a simpler and more accurate hazard assessment of low-power, near-infrared, diode laser systems than the 1986 ANSI standard. Although a specific system is evaluated, the techniques described can be readily applied to other near-infrared lasers or laser training systems.
The report discusses tests conducted at EPA's Air Pollution Prevention and Control Division to evaluate the effects of changing coals on emissions of metal hazardous air pollutants from coal-fired boilers. Six coals were burned in a 29 kW (100,000 Btu/hr) down-fired combustor und...
Beyond reducing fire hazard: fuel treatment impacts on overstory tree survival
Brandon M. Collins; Adrian J. Das; John J. Battles; Danny L. Fry; Kevin D. Krasnow; Scott L. Stephens
2014-01-01
Fuel treatment implementation in dry forest types throughout the western United States is likely to increase in pace and scale in response to increasing incidence of large wildfires. While it is clear that properly implemented fuel treatments are effective at reducing hazardous fire potential, there are ancillary ecological effects that can impact forest...
No herbicide residues found in smoke from prescribed fires
Charles K. McMahon; Parshall B. Bush
1992-01-01
Some concerns have been expressed by workers conducting prescribed burns on forest lands treated with herbicides.The major concern has based on speculation that hazardous levels of airborne herbicide residues may be present in the smoke near breathing zones of forest workers. Much of this speculation is based on fire hazard caution statements found on product labels...
Broad-Scale Assessment of Fuel Treatment Opportunities
Patrick D. Miles; Kenneth E. Skog; Wayne D. Shepperd; Elizabeth D. Reinhardt; Roger D. Fight
2006-01-01
The Forest Inventory and Analysis (FIA) program has produced estimates of the extent and composition of the Nation?s forests for several decades. FIA data have been used with a flexible silvicultural thinning option, a fire hazard model for preharvest and postharvest fire hazard assessment, a harvest economics model, and geospatial data to produce a Web-based tool to...
Spatial patterning of fuels and fire hazard across a central U.S. deciduous forest region
Michael C. Stambaugh; Daniel C. Dey; Richard P. Guyette; Hong S. He; Joseph M. Marschall
2011-01-01
Information describing spatial and temporal variability of forest fuel conditions is essential to assessing overall fire hazard and risk. Limited information exists describing spatial characteristics of fuels in the eastern deciduous forest region, particularly in dry oak-dominated regions that historically burned relatively frequently. From an extensive fuels survey...
... the fires and explosions is failure of the lithium-ion batteries. Learn how e-cigarettes work, about recent fire and explosion incidents, and why the e-cigarette/lithium-ion battery combination presents a new and unique hazard to ...
Fire technology abstracts, volume 4. Cumulative indexes
NASA Astrophysics Data System (ADS)
1982-03-01
Cumulative subject, author, publisher, and report number indexes referencing articles, books, reports, and patents are provided. The dynamics of fire, behavior and properties of materials, fire modeling and test burns, fire protection, fire safety, fire service organization, apparatus and equipment, fire prevention suppression, planning, human behavior, medical problems, codes and standards, hazard identification, safe handling of materials, and insurance economics of loss and prevention are among the subjects covered.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1987-03-01
Estimation of the costs associated with implementation of the Resource Conservation and Recovery Act (RCRA) regulations for non-hazardous and hazardous material disposal in the utility industry are provided. These costs are based on engineering studies at a number of coal-fired power plants in which the costs for hazardous and non-hazardous disposal are compared to the costs developed for the current practice design for each utility. The relationship of the three costs is displayed. The emphasis of this study is on the determination of incremental costs rather than the absolute costs for each case (current practice, non-hazardous, or hazardous). For themore » purpose of this project, the hazardous design cost was determined for both minimum and maximum compliance.« less
Use of prescribed fire to reduce wildfire potential
Robert E. Martin; J. Boone Kauffman
1989-01-01
Fires were a part of our wildlands prehistorically. Prescribed burning reduces fire hazard and potential fire behavior primarily by reducing fuel quantity and continuity. Fuel continuity should be considered on the micro scale within stands, the mid-scale among, and the macro-scale among watersheds or entire forests. Prescribed fire is only one of the tools which can...
A basic approach to fire injury of tree stems
R. E. Martin
1963-01-01
Fire has come to be widely used as a tool in wildland management, particularly in the South. Its usefulness in fire hazard reduction, removal of undesirable trees, and changing of cover types has been demonstrated. We are continually trying to improve fire use, however, by learning more of the specific effects of fire on different species of plants.
Evaluating the ecological benefits of wildfire by integrating fire and ecosystem simulation models
Robert E. Keane; Eva Karau
2010-01-01
Fire managers are now realizing that wildfires can be beneficial because they can reduce hazardous fuels and restore fire-dominated ecosystems. A software tool that assesses potential beneficial and detrimental ecological effects from wildfire would be helpful to fire management. This paper presents a simulation platform called FLEAT (Fire and Landscape Ecology...
A suite of fire, fuels, and smoke management tools
Roger D. Ottmar; Clint S. Wright; Susan J. Prichard
2009-01-01
The Fire and Environmental Research Applications Team (FERA) of the Forest Service, Pacific Northwest Research Station, is an interdisciplinary team of scientists that conduct primary research on wildland fire and provide decision support for fire hazard and smoke management. The team is committed to providing easy-to-use tools that help managers in their fire and...
Fire danger index efficiency as a function of fuel moisture and fire behavior.
Torres, Fillipe Tamiozzo Pereira; Romeiro, Joyce Machado Nunes; Santos, Ana Carolina de Albuquerque; de Oliveira Neto, Ricardo Rodrigues; Lima, Gumercindo Souza; Zanuncio, José Cola
2018-08-01
Assessment of the performance of forest fire hazard indices is important for prevention and management strategies, such as planning prescribed burnings, public notifications and firefighting resource allocation. The objective of this study was to evaluate the performance of fire hazard indices considering fire behavior variables and susceptibility expressed by the moisture of combustible material. Controlled burns were carried out at different times and information related to meteorological conditions, characteristics of combustible material and fire behavior variables were recorded. All variables analyzed (fire behavior and fuel moisture content) can be explained by the prediction indices. The Brazilian EVAP/P showed the best performance, both at predicting moisture content of the fuel material and fire behavior variables, and the Canadian system showed the best performance to predicting the rate of spread. The coherence of the correlations between the indices and the variables analyzed makes the methodology, which can be applied anywhere, important for decision-making in regions with no records or with only unreliable forest fire data. Copyright © 2018 Elsevier B.V. All rights reserved.
Sara E. Jenkins; Carolyn Hull Sieg; Diana E. Anderson; Darrell S. Kaufman; Philip A. Pearthree
2011-01-01
Long-term fire history reconstructions enhance our understanding of fire behaviour and associated geomorphic hazards in forested ecosystems. We used 14C ages on charcoal from fire-induced debris-flow deposits to date prehistoric fires on Kendrick Mountain, northern Arizona, USA. Fire-related debris-flow sedimentation dominates Holocene fan deposition in the study area...
Post-fire logging reduces surface woody fuels up to four decades following wildfire
David W. Peterson; Erich Kyle Dodson; Richy J. Harrod
2015-01-01
Severe wildfires create pulses of dead trees that influence future fuel loads, fire behavior, and fire effects as they decay and deposit surface woody fuels. Harvesting fire-killed trees may reduce future surface woody fuels and related fire hazards, but the magnitude and timing of post-fire logging effects on woody fuels have not been fully assessed. To address this...
NASA Technical Reports Server (NTRS)
1961-01-01
The nature of the potential fuel tank vent fire and explosion hazard is discussed in relation to present vent exit design practice, available knowledge of atmospheric electricity as a source of ignition energy, and the vent system vapor space environment. Flammable mixtures and possible ignition sources may occur simultaneously as a rare phenomena according to existing knowledge. There is a need to extend the state of science in order to make possible vent design which is aimed specifically at minimizing fire and explosion hazards.
NASA Astrophysics Data System (ADS)
Fustich, C. D.
1980-03-01
A series of transformer room fire tests are reported to demonstate the shock hazard present when automatic sprinklers operate over energized electrical equipment. Fire protection was provided by standard 0.5 inch pendent automatic sprinklers temperature rated at 135 F and installed to give approximately 150 sq ft per head coverage. A 480 v dry transformer was used in the room to provide a three phase, four wire distribution system. It is shown that the induced currents in the test room during the various tests are relatively small and pose no appreciable personnel shock hazard.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-16
... Utility Steam Generating Units and Standards of Performance for Fossil-Fuel-Fired Electric Utility... Performance for Fossil-Fuel-Fired Electric Utility, Industrial-Commercial-Institutional, and Small Industrial... electric utility steam generating units (EGUs) and standards of performance for fossil-fuel-fired electric...
29 CFR 1926.352 - Fire prevention.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Welding and Cutting § 1926.352 Fire prevention. (a... confine the heat, sparks, and slag, and to protect the immovable fire hazards from them. (c) No welding... for instant use. (e) When the welding, cutting, or heating operation is such that normal fire...
Code of Federal Regulations, 2012 CFR
2012-07-01
...) Has a geographic feature that aids in creating an effective fire break, such as a road or a ridge top; or (3) Is in condition class 3 as defined by HFRA. Fire hazard and risk: The fuel conditions on the landscape. Fire occurrence: The probability of wildfire ignition based on historic fire occurrence records...
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Has a geographic feature that aids in creating an effective fire break, such as a road or a ridge top; or (3) Is in condition class 3 as defined by HFRA. Fire hazard and risk: The fuel conditions on the landscape. Fire occurrence: The probability of wildfire ignition based on historic fire occurrence records...
Code of Federal Regulations, 2014 CFR
2014-07-01
...) Has a geographic feature that aids in creating an effective fire break, such as a road or a ridge top; or (3) Is in condition class 3 as defined by HFRA. Fire hazard and risk: The fuel conditions on the landscape. Fire occurrence: The probability of wildfire ignition based on historic fire occurrence records...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 5 2010-10-01 2010-10-01 false Fires. 397.11 Section 397.11 Transportation Other... PARKING RULES General § 397.11 Fires. (a) A motor vehicle containing hazardous materials must not be operated near an open fire unless its driver has first taken precautions to ascertain that the vehicle can...
14 CFR 121.221 - Fire precautions.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Fire precautions. 121.221 Section 121.221..., FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.221 Fire precautions. (a... the compartment and so that damage to or failure of the item would not create a fire hazard in the...
Fire Prevention Inspection Procedures.
ERIC Educational Resources Information Center
Pribyl, Paul F.
Lesson plans are provided for a fire prevention inspection course of the Wisconsin Fire Service Training program. Objectives for the course are to enable students to describe and conduct fire prevention inspections, to identify and correct hazards common to most occupancies, to understand the types of building construction and occupancy, and to…
Assessing impacts of fire and post-fire mitigation on runoff and erosion from rangelands
USDA-ARS?s Scientific Manuscript database
Wildfires are a natural component of rangeland ecosystems, but fires can pose hydrologic hazards for ecological resources, infrastructure, property, and human life. There has been considerable research conducted on the effects of fire on hydrologic processes and erosion on shrublands and woodlands....
29 CFR 1926.352 - Fire prevention.
Code of Federal Regulations, 2014 CFR
2014-07-01
... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Welding and Cutting § 1926.352 Fire prevention. (a... confine the heat, sparks, and slag, and to protect the immovable fire hazards from them. (c) No welding... for instant use. (e) When the welding, cutting, or heating operation is such that normal fire...
29 CFR 1926.352 - Fire prevention.
Code of Federal Regulations, 2012 CFR
2012-07-01
... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Welding and Cutting § 1926.352 Fire prevention. (a... confine the heat, sparks, and slag, and to protect the immovable fire hazards from them. (c) No welding... for instant use. (e) When the welding, cutting, or heating operation is such that normal fire...
29 CFR 1926.352 - Fire prevention.
Code of Federal Regulations, 2013 CFR
2013-07-01
... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Welding and Cutting § 1926.352 Fire prevention. (a... confine the heat, sparks, and slag, and to protect the immovable fire hazards from them. (c) No welding... for instant use. (e) When the welding, cutting, or heating operation is such that normal fire...
49 CFR 176.69 - General stowage requirements for hazardous materials.
Code of Federal Regulations, 2010 CFR
2010-10-01
... equipped with a fixed fire extinguishing and fire detection system, the freight containers or barges need... by paragraph (a) of this section if fire fighting equipment capable of reaching and piercing the..., their removal from a potentially dangerous situation, and the removal of packages in case of fire. (b...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-01
...- and Oil-Fired Electric Utility Steam Generating Units and Standards of Performance for Fossil-Fuel... Performance for Fossil-Fuel- Fired Electric Utility, Industrial-Commercial-Institutional, and Small Industrial...
33 CFR 127.601 - Fire equipment: General.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) WATERFRONT FACILITIES WATERFRONT FACILITIES HANDLING LIQUEFIED NATURAL GAS AND LIQUEFIED HAZARDOUS GAS Waterfront Facilities Handling Liquefied Natural Gas Firefighting § 127.601 Fire equipment: General. (a) Fire... Laboratories, Inc., the Factory Mutual Research Corp., or the Coast Guard. ...
33 CFR 127.601 - Fire equipment: General.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) WATERFRONT FACILITIES WATERFRONT FACILITIES HANDLING LIQUEFIED NATURAL GAS AND LIQUEFIED HAZARDOUS GAS Waterfront Facilities Handling Liquefied Natural Gas Firefighting § 127.601 Fire equipment: General. (a) Fire... Laboratories, Inc., the Factory Mutual Research Corp., or the Coast Guard. ...
Moderate Image Spectrometer (MODIS) Fire Radiative Energy: Physics and Applications
NASA Technical Reports Server (NTRS)
Kaufman, Y.
2004-01-01
MODIS fire channel does not saturate in the presence of fires. The fire channel therefore is used to estimate the fire radiative energy, a measure of the rate of biomass consumption in the fire. We found correlation between the fire radiative energy, the rate of formation of burn scars and the rate of emission of aerosol from the fires. Others found correlations between the fire radiative energy and the rate of biomass consumption. This relationships can be used to estimates the emissions from the fires and to estimate the fire hazards.
Enhancing fire department home visiting programs: results of a community intervention trial.
Gielen, Andrea C; Shields, Wendy; Frattaroli, Shannon; McDonald, Eileen; Jones, Vanya; Bishai, David; O'Brocki, Raymond; Perry, Elise C; Bates-Hopkins, Barbara; Tracey, Pat; Parsons, Stephanie
2013-01-01
This study evaluates the impact of an enhanced fire department home visiting program on community participation and installation of smoke alarms, and describes the rate of fire and burn hazards observed in homes. Communities were randomly assigned to receive either a standard or enhanced home visiting program. Before implementing the program, 603 household surveys were completed to determine comparability between the communities. During a 1-year intervention period, 171 home visits took place with 8080 homes. At baseline, 60% of homes did not have working smoke alarms on every level, 44% had unsafe water temperatures, and 72% did not have carbon monoxide alarms. Residents in the enhanced community relative to those in the standard community were significantly more likely to let the fire fighters into their homes (75 vs 62%). Among entered homes, those in the enhanced community were significantly more likely to agree to have smoke alarms installed (95 vs 92%), to be left with a working smoke alarm on every level of the home (84 vs 78%), and to have more smoke alarms installed per home visited (1.89 vs 1.74). The high baseline rates of home hazards suggest that fire department home visiting programs should take an "all hazards" approach. Community health workers and community partnerships can be effective in promoting fire departments' fire and life safety goals. Public health academic centers should partner with the fire service to help generate evidence on program effectiveness that can inform decision making about resource allocation for prevention.
Rocky Mountain Research Station USDA Forest Service
2004-01-01
Appropriate types of thinning and surface fuel treatments are clearly useful in reducing surface and crown fire hazards under a wide range of fuels and topographic situations. This paper provides well-established scientific principles and simulation tools that can be used to adjust fuel treatments to attain specific risk levels.
Limiting the immediate and subsequent hazards associated with wildfires
DeGraff, Jerome V.; Cannon, Susan H.; Parise, Mario
2013-01-01
Similarly, our capability to limit impacts from post-fire debris flows is improving. Empirical models for estimating the probability of debris-flow occurrence, the volume of such an event, and mapping the inundated area, linked with improved definitions of the rainfall conditions that trigger debris flows, can be used to provide critical information for post-fire hazard mitigation and emergency-response planning.
Peter J. Daugherty; Jeremy S. Fried
2007-01-01
Landscape-scale fuel treatments for forest fire hazard reduction potentially produce large quantities of material suitable for biomass energy production. The analytic framework FIA BioSum addresses this situation by developing detailed data on forest conditions and production under alternative fuel treatment prescriptions, and computes haul costs to alternative sites...
PEACETIME RADIATION HAZARDS IN THE FIRE SERVICE, BASIC COURSE, RESOURCE MANUAL.
ERIC Educational Resources Information Center
BERNDT, WILLIAM
FOR USE BY FIREMEN AND OTHER EMERGENCY PERSONNEL WHO MAY HAVE TO DEAL WITH FIRES OR SIMILAR EMERGENCIES INVOLVING RADIATION HAZARDS, THIS MANUAL IS CORRELATED WITH THE FOLLOWING INSTRUCTIONAL MATERIALS FOR THE 15-HOUR COURSE -- (1) AN INSTRUCTOR'S GUIDE (VT 002 117), (2) A STUDENT STUDY GUIDE (VT 001 878), AND (3) A SET OF TWENTY-TWO 20- BY…
Financial analysis of fuel treatments on national forests in the Western United States.
Roger D. Fight; R. James Barbour
2006-01-01
The purpose of this note is to provide a starting point for discussion of fire hazard reduction treatments that meet the full range of management objectives, including budget priorities. Thoughtful design requires an understanding not only of the physical and biological outcomes, but also the costs and potential revenues of applying variations of fire hazard reduction...
Lindsay A. Chiono; Danny L. Fry; Brandon M. Collins; Andrea H. Chatfield; Scott L. Stephens
2017-01-01
Forest managers are challenged with meeting numerous demands that often include wildlife habitat and carbon (C) sequestration. We used a probabilistic framework of wildfire occurrence to (1) estimate the potential for fuel treatments to reduce fire risk and hazard across the landscape and within protected California spotted owl (Strix occidentalis...
Fire and Smoke Monitoring at NOAA' Satellite Service; Applications to Smoke Forecasting
NASA Astrophysics Data System (ADS)
Stephens, G.; Ruminski, M.
2005-12-01
The Hazard Mapping System (HMS), developed and run operationally by NOAA's Satellite Services Division (SSD), is a multiplatform remote sensing approach to detecting fires and smoke over the US and adjacent areas of Canada and Mexico. The system utilizes sensors on 7 different NOAA and NASA satellites. Automated detection algorithms are employed for each of the satellites for the fire detects while smoke is delineated by an image analyst. Analyses are quality control by an analyst who inspects all available imagery and automated fire detects, deleting suspected false detects and adding fires that the automated routines miss. Graphical, text, and GIS compatible analyses are posted to a web site as soon as updates are performed, and a final product for a given day is posted early the following morning. All products are archived at NOAA's National Geophysical Data Center. Areal extent of detectable smoke is outlined using animated visible imagery, for input to a dispersion and transport model, the HYbrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT), developed by NOAA's Air Resources Laboratory (ARL). Resulting smoke forecasts will soon be used as input to NOAA's Air Quality forecasts. The GOES Aerosol and Smoke Product (GASP) is an experimental GOES imagery based aerosol optical depth (AOD) product developed by the NESDIS Office of Research and Applications, being implemented for evaluation by the NESDIS Satellite Analysis Branch for use in smoke and volcanic ash monitoring. Currently, research is underway in NESDIS' Office of Research and Applications to objectivize smoke delineation using GASP and MODIS AOD retrievals. NOAA's Operational Significant Event Imagery (OSEI) program processes satellite imagery of environmentally significant events, including fire, smoke and volcanic ash, visible in operational satellite data. This imagery is often referred to by fire managers and air quality agencies. Future plans include the integration of high resolution global data from the European Space Agency's MetOp satellite and global geostationary satellites.
NASA Hydrogen Peroxide Propellant Hazards Technical Manual
NASA Technical Reports Server (NTRS)
Baker, David L.; Greene, Ben; Frazier, Wayne
2005-01-01
The Fire, Explosion, Compatibility and Safety Hazards of Hydrogen Peroxide NASA technical manual was developed at the NASA Johnson Space Center White Sands Test Facility. NASA Technical Memorandum TM-2004-213151 covers topics concerning high concentration hydrogen peroxide including fire and explosion hazards, material and fluid reactivity, materials selection information, personnel and environmental hazards, physical and chemical properties, analytical spectroscopy, specifications, analytical methods, and material compatibility data. A summary of hydrogen peroxide-related accidents, incidents, dose calls, mishaps and lessons learned is included. The manual draws from art extensive literature base and includes recent applicable regulatory compliance documentation. The manual may be obtained by United States government agencies from NASA Johnson Space Center and used as a reference source for hazards and safe handling of hydrogen peroxide.
Code of Federal Regulations, 2011 CFR
2011-04-01
... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.201 Scope. The purpose of this subpart is to set forth requirements that will assure reasonable fire safety to the occupants by reducing fire hazards and by providing measures for early detection. ...
Code of Federal Regulations, 2013 CFR
2013-04-01
... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.201 Scope. The purpose of this subpart is to set forth requirements that will assure reasonable fire safety to the occupants by reducing fire hazards and by providing measures for early detection. ...
Code of Federal Regulations, 2010 CFR
2010-04-01
... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.201 Scope. The purpose of this subpart is to set forth requirements that will assure reasonable fire safety to the occupants by reducing fire hazards and by providing measures for early detection. ...
Code of Federal Regulations, 2012 CFR
2012-04-01
... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.201 Scope. The purpose of this subpart is to set forth requirements that will assure reasonable fire safety to the occupants by reducing fire hazards and by providing measures for early detection. ...
Code of Federal Regulations, 2014 CFR
2014-04-01
... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.201 Scope. The purpose of this subpart is to set forth requirements that will assure reasonable fire safety to the occupants by reducing fire hazards and by providing measures for early detection. ...
Fire danger rating in the United States of America: An evolution since 1916
Colin C. Hardy; Charles E. Hardy
2007-01-01
Fire scientists in the United States began exploring the relationships of fire-danger and hazard with weather, fuel moisture, and ignition probabilities as early as 1916. Many of the relationships identified then persist today in the form of our National Fire-Danger-Rating System. This paper traces the evolution of fire-danger rating in the United States, including...
ERIC Educational Resources Information Center
Texas State Commission on Fire Protection, Austin.
This booklet comprises the third grade component of a series of curriculum guides on fire and burn prevention. Designed to meet the age-specific needs of third grade students, its objectives include: (1) acquiring basic knowledge of hazards and safe storage of flammable liquids; and (2) developing positive actions to prevent fires and burns or to…
ERIC Educational Resources Information Center
Texas State Commission on Fire Protection, Austin.
This booklet comprises the first grade component of a series of curriculum guides on fire and burn prevention. Designed to meet the age-specific needs of first grade students, its objectives include acquiring basic knowledge of fire and burn hazards, developing a basic understanding of simple injury reduction, and encouraging parent involvement.…
Cannon, Susan H.; Michael, John A.
2011-01-01
This report presents an emergency assessment of potential debris-flow hazards from basins burned by the 2011 Motor fire in the Sierra and Stanislaus National Forests, Calif. Statistical-empirical models are used to estimate the probability and volume of debris flows that may be produced from burned drainage basins as a function of different measures of basin burned extent, gradient, and soil physical properties, and in response to a 30-minute-duration, 10-year-recurrence rainstorm. Debris-flow probability and volume estimates are then combined to form a relative hazard ranking for each basin. This assessment provides critical information for issuing warnings, locating and designing mitigation measures, and planning evacuation timing and routes within the first two years following the fire.
Development of fire resistant electronic configurations for use in oxygen enriched environments
NASA Technical Reports Server (NTRS)
Smith, F. J.
1975-01-01
Design concepts for electronic black boxes and modules were tested in oxygen enriched atmospheres, and it was found that various types of sealed configurations would generally eliminate any flammability hazard. The type of configuration and its construction was found to be of more importance in the elimination of flammability hazards in electronic configurations than the types of materials utilized in them. The design concepts developed for fire hazard free electronic configurations for use in manned space programs are applicable for the design of electronic hardware for any use or environment.
AEGIS: a wildfire prevention and management information system
Kostas Kalabokidis; Alan Ager; Mark Finney; Nikos Athanasis; Palaiologos Palaiologou; Christos Vasilakos
2016-01-01
We describe a Web-GIS wildfire prevention and management platform (AEGIS) developed as an integrated and easy-to-use decision support tool to manage wildland fire hazards in Greece (http://aegis.aegean.gr). The AEGIS platform assists with early fire warning, fire planning, fire control and coordination of firefighting forces by providing online access to...
NASA Technical Reports Server (NTRS)
1978-01-01
An early warning fire detection sensor developed for NASA's Space Shuttle Orbiter is being evaluated as a possible hazard prevention system for mining operations. The incipient Fire Detector represents an advancement over commercially available smoke detectors in that it senses and signals the presence of a fire condition before the appearance of flame and smoke, offering an extra margin of safety.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-28
...-Fired Electric Utility Steam Generating Units and Standards of Performance for Fossil-Fuel-Fired... Units and Standards of Performance for Fossil-Fuel-Fired Electric Utility, Industrial-Commercial... copy form. The hearing schedules, including lists of speakers, will be posted on EPA's Web Sites http...
30 CFR 77.1108-1 - Type and capacity of firefighting equipment.
Code of Federal Regulations, 2010 CFR
2010-07-01
... UNDERGROUND COAL MINES Fire Protection § 77.1108-1 Type and capacity of firefighting equipment. Firefighting... capacity for each 1,000 tons of coal processed (average) per shift. (b) Fire extinguishers. Fire extinguishers shall be: (1) Of the appropriate type for the particular fire hazard involved; (2) Adequate in...
Spatially explicit modeling of mixed-severity fire regimes and landscape dynamics
Michael C. Wimberly; Rebecca S.H. Kennedy
2008-01-01
Simulation models of disturbance and succession are being increasingly applied to characterize landscape composition and dynamics under natural fire regimes, and to evaluate alternative management strategies for ecological restoration and fire hazard reduction. However, we have a limited understanding of how landscapes respond to changes in fire frequency, and about...
30 CFR 77.1108-1 - Type and capacity of firefighting equipment.
Code of Federal Regulations, 2011 CFR
2011-07-01
... UNDERGROUND COAL MINES Fire Protection § 77.1108-1 Type and capacity of firefighting equipment. Firefighting... capacity for each 1,000 tons of coal processed (average) per shift. (b) Fire extinguishers. Fire extinguishers shall be: (1) Of the appropriate type for the particular fire hazard involved; (2) Adequate in...
NASA Technical Reports Server (NTRS)
Juarez, Alfredo; Harper, Susan A.; Hirsch, David B.; Carriere, Thierry
2013-01-01
Many sources of fuel are present aboard current spacecraft, with one especially hazardous source of stored energy: lithium ion batteries. Lithium ion batteries are a very hazardous form of fuel due to their self-sustaining combustion once ignited, for example, by an external heat source. Batteries can become extremely energetic fire sources due to their high density electrochemical energy content that may, under duress, be violently converted to thermal energy and fire in the form of a thermal runaway. Currently, lithium ion batteries are the preferred types of batteries aboard international spacecraft and therefore are routinely installed, collectively forming a potentially devastating fire threat to a spacecraft and its crew. Currently NASA is developing a fine water mist portable fire extinguisher for future use on international spacecraft. As its development ensues, a need for the standard evaluation of various types of fire extinguishers against this potential threat is required to provide an unbiased means of comparing between fire extinguisher technologies and ranking them based on performance.
NASA Technical Reports Server (NTRS)
Coulbert, C. D.
1978-01-01
A method for predicting the probable course of fire development in an enclosure is presented. This fire modeling approach uses a graphic plot of five fire development constraints, the relative energy release criteria (RERC), to bound the heat release rates in an enclosure as a function of time. The five RERC are flame spread rate, fuel surface area, ventilation, enclosure volume, and total fuel load. They may be calculated versus time based on the specified or empirical conditions describing the specific enclosure, the fuel type and load, and the ventilation. The calculation of these five criteria, using the common basis of energy release rates versus time, provides a unifying framework for the utilization of available experimental data from all phases of fire development. The plot of these criteria reveals the probable fire development envelope and indicates which fire constraint will be controlling during a criteria time period. Examples of RERC application to fire characterization and control and to hazard analysis are presented along with recommendations for the further development of the concept.
Wildfire air pollution hazard during the 21st century
NASA Astrophysics Data System (ADS)
Knorr, Wolfgang; Dentener, Frank; Lamarque, Jean-François; Jiang, Leiwen; Arneth, Almut
2017-07-01
Wildfires pose a significant risk to human livelihoods and are a substantial health hazard due to emissions of toxic smoke. Previous studies have shown that climate change, increasing atmospheric CO2, and human demographic dynamics can lead to substantially altered wildfire risk in the future, with fire activity increasing in some regions and decreasing in others. The present study re-examines these results from the perspective of air pollution risk, focussing on emissions of airborne particulate matter (PM2. 5), combining an existing ensemble of simulations using a coupled fire-dynamic vegetation model with current observation-based estimates of wildfire emissions and simulations with a chemical transport model. Currently, wildfire PM2. 5 emissions exceed those from anthropogenic sources in large parts of the world. We further analyse two extreme sets of future wildfire emissions in a socio-economic, demographic climate change context and compare them to anthropogenic emission scenarios reflecting current and ambitious air pollution legislation. In most regions of the world, ambitious reductions of anthropogenic air pollutant emissions have the potential to limit mean annual pollutant PM2. 5 levels to comply with World Health Organization (WHO) air quality guidelines for PM2. 5. Worst-case future wildfire emissions are not likely to interfere with these annual goals, largely due to fire seasonality, as well as a tendency of wildfire sources to be situated in areas of intermediate population density, as opposed to anthropogenic sources that tend to be highest at the highest population densities. However, during the high-fire season, we find many regions where future PM2. 5 pollution levels can reach dangerous levels even for a scenario of aggressive reduction of anthropogenic emissions.
Battipaglia, Giovanna; Savi, Tadeja; Ascoli, Davide; Castagneri, Daniele; Esposito, Assunta; Mayr, Stefan; Nardini, Andrea
2016-08-01
Prescribed burning (PB) is a widespread management technique for wildfire hazard abatement. Understanding PB effects on tree ecophysiology is key to defining burn prescriptions aimed at reducing fire hazard in Mediterranean pine plantations, such as Pinus pinea L. stands. We assessed physiological responses of adult P. pinea trees to PB using a combination of dendroecological, anatomical, hydraulic and isotopic analyses. Tree-ring widths, xylem cell wall thickness, lumen area, hydraulic diameter and tree-ring δ(13)C and δ(18)O were measured in trees on burned and control sites. Vulnerability curves were elaborated to assess tree hydraulic efficiency or safety. Despite the relatively intense thermal treatment (the residence time of temperatures above 50 °C at the stem surface ranged between 242 and 2239 s), burned trees did not suffer mechanical damage to stems, nor significant reduction in radial growth. Moreover, the PB did not affect xylem structure and tree hydraulics. No variations in (13)C-derived water use efficiency were recorded. This confirmed the high resistance of P. pinea to surface fire at the stem base. However, burned trees showed consistently lower δ(18)O values in the PB year, as a likely consequence of reduced competition for water and nutrients due to the understory burning, which increased both photosynthetic activity and stomatal conductance. Our multi-approach analysis offers new perspectives on post-fire survival strategies of P. pinea in an environment where fires are predicted to increase in frequency and severity during the 21st century. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Fire Safety of Passenger Trains : Phase II : Application of Fire Hazard Analysis Techniques
DOT National Transportation Integrated Search
2001-12-01
On May 12, 1999, the Federal Railroad Administration (FRA) issued regulations for passenger rail equipment safety standards that included small-scale fire tests and performance criteria to evaluate the flammability and smoke characteristics of indivi...
Fire safety of passenger trains. Phase II, Application of fire hazard analysis techniques.
DOT National Transportation Integrated Search
2001-12-01
On May 12, 1999, the Federal Railroad Administration (FRA) issued regulations for passenger rail equipment safety standards that included small-scale fire tests and performance criteria to evaluate the flammability and smoke characteristics of indivi...
AEGIS: a wildfire prevention and management information system
NASA Astrophysics Data System (ADS)
Kalabokidis, Kostas; Ager, Alan; Finney, Mark; Athanasis, Nikos; Palaiologou, Palaiologos; Vasilakos, Christos
2016-03-01
We describe a Web-GIS wildfire prevention and management platform (AEGIS) developed as an integrated and easy-to-use decision support tool to manage wildland fire hazards in Greece (http://aegis.aegean.gr). The AEGIS platform assists with early fire warning, fire planning, fire control and coordination of firefighting forces by providing online access to information that is essential for wildfire management. The system uses a number of spatial and non-spatial data sources to support key system functionalities. Land use/land cover maps were produced by combining field inventory data with high-resolution multispectral satellite images (RapidEye). These data support wildfire simulation tools that allow the users to examine potential fire behavior and hazard with the Minimum Travel Time fire spread algorithm. End-users provide a minimum number of inputs such as fire duration, ignition point and weather information to conduct a fire simulation. AEGIS offers three types of simulations, i.e., single-fire propagation, point-scale calculation of potential fire behavior, and burn probability analysis, similar to the FlamMap fire behavior modeling software. Artificial neural networks (ANNs) were utilized for wildfire ignition risk assessment based on various parameters, training methods, activation functions, pre-processing methods and network structures. The combination of ANNs and expected burned area maps are used to generate integrated output map of fire hazard prediction. The system also incorporates weather information obtained from remote automatic weather stations and weather forecast maps. The system and associated computation algorithms leverage parallel processing techniques (i.e., High Performance Computing and Cloud Computing) that ensure computational power required for real-time application. All AEGIS functionalities are accessible to authorized end-users through a web-based graphical user interface. An innovative smartphone application, AEGIS App, also provides mobile access to the web-based version of the system.
Nicole M. Vaillant; Elizabeth D. Reinhardt
2017-01-01
The National Cohesive Wildland Fire Management Strategy recognizes that wildfire is a necessary natural process in many ecosystems and strives to reduce conflicts between fire-prone landscapes and people. In an effort to mitigate potential negative wildfire impacts proactively, the Forest Service fuels program reduces wildland fuels. As part of an internal program...
Patrick H. Brose; Dale Wade
2002-01-01
The 1998 wildfires in Florida sparked a serious debate about the accumulation of hazardous forest fuels and the merits of prescribed fire and alternatives for mitigating that problem. One such alternative is application of understory herbicides and anecdotal evidence suggests they may either exacerbate or lessen the fuel accumulation problem. In 1998, a study was...
Jessica E. Halofsky; Stephanie K. Hart; Miles A. Hemstrom; Joshua S. Halofsky; Morris C. Johnson
2014-01-01
Information on the effects of management activities such as fuel reduction treatments and of processes such as vegetation growth and disturbance on fire hazard can help land managers prioritize treatments across a landscape to best meet management goals. State-and-transition models (STMs) allow landscape-scale simulations that incorporate effects of succession,...
The effect of leaf beetle herbivory on the fire behaviour of tamarisk (Tamarix ramosissima Lebed.)
Drus, Gail M.; Dudley, Tom L.; Brooks, Matthew L.; Matchett, John R.
2012-01-01
The non-native tree, Tamarix spp. has invaded desert riparian ecosystems in the south-western United States. Fire hazard has increased, as typically fire-resistant native vegetation is replaced by Tamarix. The tamarisk leaf beetle, Diorhabda carinulata Desbrochers, introduced for biological control, may affect fire behaviour by converting hydrated live Tamarix leaves and twigs into desiccated and dead fuels. This potentially increases fire hazard in the short term before native vegetation can be re-established. This study investigates how fire behaviour is altered in Tamarix fuels desiccated by Diorhabda herbivory at a Great Basin site, and by herbivory simulated by foliar herbicide at a Mojave Desert site. It also evaluates the influence of litter depth on fire intensity. Fire behaviour was measured with a fire intensity index that integrates temperature and duration (degree-minutes above 70°C), and with maximum temperature, duration, flame lengths, rates of spread and vegetation removal. Maximum temperature, flame length and rate of spread were enhanced by foliar desiccation of Tamarix at both sites. At only the Mojave site, there was a trend for desiccated trees to burn with greater fire intensity. At both sites, fire behaviour parameters were influenced to a greater degree by litter depth, vegetation density and drier and windier conditions than by foliar desiccation.
LANDFIRE: A nationally consistent vegetation, wildland fire, and fuel assessment
Rollins, Matthew G.
2009-01-01
LANDFIRE is a 5-year, multipartner project producing consistent and comprehensive maps and data describing vegetation, wildland fuel, fire regimes and ecological departure from historical conditions across the United States. It is a shared project between the wildland fire management and research and development programs of the US Department of Agriculture Forest Service and US Department of the Interior. LANDFIRE meets agency and partner needs for comprehensive, integrated data to support landscape-level fire management planning and prioritization, community and firefighter protection, effective resource allocation, and collaboration between agencies and the public. The LANDFIRE data production framework is interdisciplinary, science-based and fully repeatable, and integrates many geospatial technologies including biophysical gradient analyses, remote sensing, vegetation modelling, ecological simulation, and landscape disturbance and successional modelling. LANDFIRE data products are created as 30-m raster grids and are available over the internet at www.landfire.gov, accessed 22 April 2009. The data products are produced at scales that may be useful for prioritizing and planning individual hazardous fuel reduction and ecosystem restoration projects; however, the applicability of data products varies by location and specific use, and products may need to be adjusted by local users.
Anne E. Black; Peter Landres
2012-01-01
Current fire policy to restore ecosystem function and resiliency and reduce buildup of hazardous fuels implies a larger future role for fire (both natural and human ignitions) (USDA Forest Service and U.S. Department of the Interior 2000). Yet some fire management (such as building fire line, spike camps, or helispots) potentially causes both short- and longterm...
Martha A. Williamson
2007-01-01
United States wildland fire policy and program reviews in 1995 and 2000 required both the reduction of hazardous fuel and recognition of fire as a natural process. Despite the fact that existing policy permits managing natural ignitions to meet resource benefits, or Wildland Fire Use (WFU), most fuel reduction projects rely on mechanical treatments and prescribed fire...
R.E.J. Boerner; J. Huang; S.C. Hart
2009-01-01
The Fire and Fire Surrogates (FFS) network is composed of 12 forest sites that span the continental United States, all of which historically had frequent low-severity fire. The goal of the FFS study was to assess the efficacy of three management treatments (prescribed fire, mechanical thinning, and their combination) in reducing wildfire hazard and increasing ecosystem...
Estimation of Wild Fire Risk Area based on Climate and Maximum Entropy in Korean Peninsular
NASA Astrophysics Data System (ADS)
Kim, T.; Lim, C. H.; Song, C.; Lee, W. K.
2015-12-01
The number of forest fires and accompanying human injuries and physical damages has been increased by frequent drought. In this study, forest fire danger zone of Korea is estimated to predict and prepare for future forest fire hazard regions. The MaxEnt (Maximum Entropy) model is used to estimate the forest fire hazard region which estimates the probability distribution of the status. The MaxEnt model is primarily for the analysis of species distribution, but its applicability for various natural disasters is getting recognition. The detailed forest fire occurrence data collected by the MODIS for past 5 years (2010-2014) is used as occurrence data for the model. Also meteorology, topography, vegetation data are used as environmental variable. In particular, various meteorological variables are used to check impact of climate such as annual average temperature, annual precipitation, precipitation of dry season, annual effective humidity, effective humidity of dry season, aridity index. Consequently, the result was valid based on the AUC(Area Under the Curve) value (= 0.805) which is used to predict accuracy in the MaxEnt model. Also predicted forest fire locations were practically corresponded with the actual forest fire distribution map. Meteorological variables such as effective humidity showed the greatest contribution, and topography variables such as TWI (Topographic Wetness Index) and slope also contributed on the forest fire. As a result, the east coast and the south part of Korea peninsula were predicted to have high risk on the forest fire. In contrast, high-altitude mountain area and the west coast appeared to be safe with the forest fire. The result of this study is similar with former studies, which indicates high risks of forest fire in accessible area and reflects climatic characteristics of east and south part in dry season. To sum up, we estimated the forest fire hazard zone with existing forest fire locations and environment variables and had meaningful result with artificial and natural effect. It is expected to predict future forest fire risk with future climate variables as the climate changes.
Fire safety design considerations for advanced space vehicles
NASA Technical Reports Server (NTRS)
1988-01-01
The desire to understand and explore space has driven man to overcome the confines of the Earth's atmosphere and accept the challenge of spaceflight. With our increasing ability to travel, work, and explore in space comes a need for a better understanding of the hazards in this relatively new endeavor. One of the most important and immediate needs is to be able to predict the ignition, spread, and growth of fire on board spacecraft. Fire safety aboard spacecraft has always been a concern; however, with the increasing number and duration of proposed missions, it is imperative that the spacecraft be designed with a solid understanding of fire hazards, insuring that all risks have been minimized and extinguishment systems are available.
PREFER: a European service providing forest fire management support products
NASA Astrophysics Data System (ADS)
Eftychidis, George; Laneve, Giovanni; Ferrucci, Fabrizio; Sebastian Lopez, Ana; Lourenco, Louciano; Clandillon, Stephen; Tampellini, Lucia; Hirn, Barbara; Diagourtas, Dimitris; Leventakis, George
2015-06-01
PREFER is a Copernicus project of the EC-FP7 program which aims developing spatial information products that may support fire prevention and burned areas restoration decisions and establish a relevant web-based regional service for making these products available to fire management stakeholders. The service focuses to the Mediterranean region, where fire risk is high and damages from wildfires are quite important, and develop its products for pilot areas located in Spain, Portugal, Italy, France and Greece. PREFER aims to allow fire managers to have access to online resources, which shall facilitate fire prevention measures, fire hazard and risk assessment, estimation of fire impact and damages caused by wildfire as well as support monitoring of post-fire regeneration and vegetation recovery. It makes use of a variety of products delivered by space borne sensors and develop seasonal and daily products using multi-payload, multi-scale and multi-temporal analysis of EO data. The PREFER Service portfolio consists of two main suite of products. The first refers to mapping products for supporting decisions concerning the Preparedness/Prevention Phase (ISP Service). The service delivers Fuel, Hazard and Fire risk maps for this purpose. Furthermore the PREFER portfolio includes Post-fire vegetation recovery, burn scar maps, damage severity and 3D fire damage assessment products in order to support relative assessments required in context of the Recovery/Reconstruction Phase (ISR Service) of fire management.
Station set requirements document. Volume 82: Fire support. Book 2: Preliminary functional fire plan
NASA Technical Reports Server (NTRS)
Gray, N. C.
1974-01-01
The fire prevention/protection requirements for all shuttle facility and ground support equipment are presented for the hazardous operations. These include: preparing the orbiter for launch, launch operations, landing operations, safing operations, and associated off-line activities.
Learning from escaped prescribed fires - lessons for high reliability
Deirdre Dether; Anne Black
2006-01-01
Meeting national goals for hazardous fuels reduction and ecosystem restoration would be difficult - if not impossible - without utilizing prescribed fire. Suspension of prescribed fire programs, as often happens following an escape, limits Federal capacity to meet programmatic, social, and ecological goals.
76 FR 62755 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-11
... wild land urban interface homeowners. The information collected will help wildland fire managers and... a currently valid OMB control number. Forest Service Title: Overcoming Barriers to Wildland Fire... information regarding barriers to participating in fire hazard reduction programs in the wildland urban...
Code of Federal Regulations, 2010 CFR
2010-10-01
.... (j) Fire-detecting and fire-extinguishing equipment. (k) Pollution-prevention equipment. (l) Sanitary condition. (m) Fire hazards. (n) Verification of validity of certificates required and issued by the Federal Communications Commission. (o) Lights and signals as required by the applicable navigational rules. (p) Tests and...
NASA Technical Reports Server (NTRS)
Hillenbrand, L. J.; Wray, J. A.
1973-01-01
The plans for the present series of full-scale experimental fires were initiated at the suggestion of NASA following the presentation of a film and discussion illustrating Battelle-Columbus' recent work in fire research. That film showed bedroom-type fires carried out as a part of a program to determine the influence of the cyclic characteristics of real fires under limited ventilation on the burning and pyrolysis properties of the room furnishings. A new series of fires was suggested by NASA designed to show the performance of new fire resistant and fire retardant materials by providing comparative fire and smoldering environmental conditions. More recently, the goal for the new series of fires was written in a meeting with NASA personnel and others at Battelle on May 3 and 4, 1972. The goal was as follows: To establish the need for special materials of improved fire safety in domiciliary settings of public concern, and to assess, in a professionally acceptable manner, the potential of materials arising from the new space-age technology for this purpose. It was anticipated that some new materials arising from the space-age technology and not yet available through conventional commercial channels might provide significant improvements in fire safety if the best of the commercially available materials showed important shortcomings in this area. It was the intent of this program to assess the benefits that could accrue from the use of these new materials. Fire safety is a matter requiring the evaluation of a number of factors. For example, fire resistance and fire spread, visibility during the fire, toxicity of evolved gases, and the fire-fighting problem that is created must be evaluated before the relative hazard can be assessed. The plan of the program provided for sampling and instrumentation to evaluate these factors, consistent with the goal of technological utilization that has been specified. Arrangements were made with the Columbus Fire Department to use an existing six-story concrete building', designed and used as a fire training tower, as the site for the experimental fires. The visual evidence provided by TV and photographic coverage of the four experimental room fires showed clearly that the rooms responded very differently to a common ignition condition. In particular: (1) The Typical room, furnished from conventional retail sources, ignited easily and burned rapidly so that after 8 minutes the contents of the room were nearly destroyed. (2) The Improved room, furnished with materials selected as being among the best commercially available, showed substantial improvement over the Typical room in that there was slower fire spread. However, the relatively complete destruction of the room contents that resulted, and the large amounts of smoke, made it clear that substantial further improvements were needed. This fire was stopped after 29 minutes. (3) The Space-age room, furnished completely with new materials that were not yet commercially available, did not ignite under the common ignition condition and soon demonstrated the substantial improvement in fire resistance available for those components close to the ignition source. A second and larger ignition arrangement showed that this room can burn, but the difficulty with which this was brought about confirmed the improved fire resistance available with use of these materials. (4) The Mixed room ensemble, furnished with 'materials identical to the Typical room except for the substitution of the bed from the Space-age room, illustrated the improvement in control of fire spread available by careful placement of fire materials in the important paths of fire development of an otherwise ordinary room. The most significant hazards at early times in each fire were due to the rapid rise in heat flux and the abrupt obscuration of vision by smoke. The most consistent toxicity hazard was due to CO and its importance would depend on the ability of the occupant to survive the initial heat and smoke menace which characterized each fire room. Other gases and vapors were shown to reach hazardous levels in certain fire rooms and, again, their significance to an occupant, would relate to the times in which such hazards occurred, and probably to the synergistic nature of the hazard arising from mixtures of such gases. Fire retardant items in the room are caused to pyrolyze by the heat of burning from other items in the room and so contribute to combustible and toxic vapor accumulations, even though they may not have entered into the burning process. This effect of a mixture of combustible materials to produce burning and pyrolysis not characteristic of any one item individually we have chosen to call the "ensemble effect". Further full-scale fire trials may be expected to show the significant changes that control the burning and pyrolytic processes and in that event a programmed fire chamber should be developed to yield realistic laboratory results.
Wildfire Research in an Environmental Hazards Course: An Active Learning Approach
ERIC Educational Resources Information Center
Wall, Tamara U.; Halvorson, Sarah J.
2011-01-01
Creating opportunities for students to actively apply hazards theory to real-life situations is often a challenge in hazards geography courses. This article presents a project, the Jocko Lakes Fire Project, that implemented learning strategies to encourage students to be active in wildfire hazards research. Wildfire hazards stand out as an…
Nicole M. Vaillant; Erin K. Noonan-Wright; Alicia L. Reiner; Carol M. Ewell; Benjamin M. Rau; Josephine A. Fites-Kaufman; Scott N. Dailey
2015-01-01
Altered fuel conditions coupled with changing climate have disrupted fire regimes of forests historically characterised by high-frequency and low-to-moderate-severity fire. Managers use fuel treatments to abate undesirable fire behaviour and effects. Short-term effectiveness of fuel treatments to alter fire behaviour and effects is well documented; however, long-term...
Putting out fire with gasoline: pitfalls in the silvicultural treatment of canopy fuels
Christopher R. Keyes; J. Morgan Varner
2007-01-01
There is little question that forest stand structure is directly related to fire behavior, and that canopy fuel structure may be altered using silvicultural methods to successfully modify forest fire behavior and reduce susceptibility to crown fire initiation and spread. Silvicultural treatments can remediate hazardous stand structures that have developed as a result...
Economic Impact of Fire Weather Forecasts
Don Gunasekera; Graham Mills; Mark Williams
2006-01-01
Southeastern Australia, where the State of Victoria is located is regarded as one of the most fire prone areas in the world. The Australian Bureau of Meteorology provides fire weather services in Victoria as part of a national framework for the provision of such services. These services range from fire weather warnings to special forecasts for hazard reduction burns....
Behaviour and effects of prescribed fire in masticated fuelbeds
Eric Knapp; J. Morgan Varner; Matt Busse; Carl Skinner; Carol Shestak
2011-01-01
Mechanical mastication converts shrub and small tree fuels into surface fuels, and this method is being widely used as a treatment to reduce fire hazard. The compactness of these fuelbeds is thought to moderate fire behaviour, but whether standard fuel models can accurately predict fire behaviour and effects is poorly understood. Prescribed burns were conducted in...
Rocky Mountain Research Station USDA Forest Service
2004-01-01
The principal goals of fuel treatments are to reduce fireline intensities, reduce the potential for crown fires, improve opportunities for successful fire suppression, and improve forest resilience to forest fires. This fact sheet discusses thinning, and surface fuel treatments, as well as challenges associated with those treatments.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-27
... CONSUMER PRODUCT SAFETY COMMISSION 16 CFR Part Chapter II Fire Pots and Gel Fuel; Advance Notice... comments received, go to http://www.regulations.gov . FOR FURTHER INFORMATION CONTACT: Rohit Khanna, Fire..., they can present serious burn and fire hazards. Firepots and gel fuel are usually sold as separate...
Quantifying the effect of fuel reduction treatments on fire behavior in boreal forests
B.W. Butler; R.D. Ottmar; T.S. Rupp; R. Jandt; E. Miller; K. Howard; R. Schmoll; S. Theisen; R.E. Vihnanek; D. Jimenez
2013-01-01
Mechanical (e.g., shearblading) and manual (e.g., thinning) fuel treatments have become the preferred strategy of many fire managers and agencies for reducing fire hazard in boreal forests. This study attempts to characterize the effectiveness of four fuel treatments through direct measurement of fire intensity and forest floor consumption during a single prescribed...
Potential fire behavior in pine flatwood forests following three different fuel reduction techniques
Patrick Brose; Dale Wade
2002-01-01
A computer modeling study to determine the potential fire behavior in pine flatwood forests following three fuel hazard reduction treatments: herbicide, prescribed fire and thinning was conducted in Florida following the 1998 wildfire season. Prescribed fire provided immediate protection but this protection quickly disappeared as the rough recovered. Thinning had a...
Philip N. Omi; Linda A. Joyce
2003-01-01
Recent fires have spawned intense interest in fuel treatment and ecological restoration activities. Scientists and land managers have been advocating these activities for years, and the recent fires have provided incentives for federal, state, and local entities to move ahead with ambitious hazard reduction and restoration projects. Recent fires also have increased...
Influences on USFS District Rangers' Decision to Authorize Wildland Fire Use
Martha A. Williamson
2006-01-01
United States wildland fire policy and program reviews in 1995 and 2000 required reduction of hazardous fuel and recognition of fire as a natural process. Although an existing policy, Wildland Fire Use (WFU), permitted managing natural ignitions to meet resource benefits, most fuel reduction is still achieved through mechanical treatments and prescribed burning....
Lorz, C; Fürst, C; Galic, Z; Matijasic, D; Podrazky, V; Potocic, N; Simoncic, P; Strauch, M; Vacik, H; Makeschin, F
2010-12-01
We assessed the probability of three major natural hazards--windthrow, drought, and forest fire--for Central and South-Eastern European forests which are major threats for the provision of forest goods and ecosystem services. In addition, we analyzed spatial distribution and implications for a future oriented management of forested landscapes. For estimating the probability of windthrow, we used rooting depth and average wind speed. Probabilities of drought and fire were calculated from climatic and total water balance during growing season. As an approximation to climate change scenarios, we used a simplified approach with a general increase of pET by 20%. Monitoring data from the pan-European forests crown condition program and observed burnt areas and hot spots from the European Forest Fire Information System were used to test the plausibility of probability maps. Regions with high probabilities of natural hazard are identified and management strategies to minimize probability of natural hazards are discussed. We suggest future research should focus on (i) estimating probabilities using process based models (including sensitivity analysis), (ii) defining probability in terms of economic loss, (iii) including biotic hazards, (iv) using more detailed data sets on natural hazards, forest inventories and climate change scenarios, and (v) developing a framework of adaptive risk management.
Fire and Children: Learning Survival Skills.
ERIC Educational Resources Information Center
Block, Jeanne H.; And Others
This paper describes a study designed to investigate: (1) children's interest in, anxieties about, attitudes toward, and reactions to fire; (2) the relationship of particular personality characteristics to attitudes about and behavior with potentially hazardous fire material; (3) socialization techniques and teaching strategies of mothers in…
Occupational burns from oxygen resuscitator fires: the hazard of aluminum regulators.
Hodous, Thomas K; Washenitz, Frank; Newton, Barry
2002-07-01
There have been over 30 incidents of oxygen resuscitator fires over the last 6 years, causing severe burns to a number of fire fighters, emergency medical service personnel, health care workers, and patients. The National Institute for Occupational Safety and Health (NIOSH) was requested to investigate three such incidents. NIOSH conducted site investigations of the incidents, and the requesters also sent the involved oxygen resuscitators to a forensic engineering company for a causal analysis. The investigated fires were associated with aluminum regulators, all from one manufacturer, on compressed pure oxygen cylinders. The investigations indicated that the cause of the fires was an initial small ignition in the high-pressure area of the aluminum regulator, which then consumed itself in a massive burnout. Aluminum regulators used with high-pressure oxygen systems are subject to rare, but potentially catastrophic combustion in normal use. Replacement of such regulators with those made of more fire-resistant materials or designs, as well as education and improved safety practices are needed to reduce this hazard.
Robert L. Ryan; Mark B. Wamsley
2006-01-01
We surveyed residents of fire-prone areas of the Central Pine Barrens of Long Island, New York, and the Plymouth Pine Barrens in Massachusetts to learn how they perceived wildland fire risk and management techniques for reducing fire hazard. We found that residents considered the fire threat to their own property to be relatively low in spite of first-hand experience...
Assessing the home fire safety of urban older adults: a case study.
Twyman, Stephanie; Fahey, Erin; Lehna, Carlee
2014-01-01
Older adults are at a higher risk for fatal house fire injury due to decreased mobility, chronic illness, and lack of smoke alarms. The purpose of this illustrative case study is to describe the home fire safety (HFS) status of an urban older adult who participated in a large study funded by the Federal Emergency Management Agency (FEMA). During a home visit with the participant, HFS data were collected from documents, observation, physical artifacts, reflective logs, and interviews. Numerous HFS hazards were identified including non-working smoke alarms, inadequate number and inappropriate placement of smoke alarms, lack of carbon monoxide (CO) alarms, inability to identify a home fire escape plan, hot water heater temperature set too high, and cooking hazards. Identification of HFS risk factors will assist in the development of educational materials that can be tailored to the older adult population to decrease their risk of fire-related injuries and death.
SP industry calorimeter for rate of heat release measurements up to 10MW
NASA Astrophysics Data System (ADS)
Dahlberg, Martin
The Swedish National Testing and Research Institute (SP) has installed a 10 MW fire calorimeter for rate of heat release measurements, similar to the one at Factory Mutual Research Corporation (FMRC). It can be used to classify commodities with respect to their fire hazard, to evaluate the efficiency of sprinkler systems, for chemical analysis of the combustion gases from hazardous fires, to produce input data for the fire modelling, etc. A large hood collects the fire gases and leads them into a duct where gas velocity, gas temperature, smoke density, and contents of oxygen, carbon dioxide, and carbon monoxide are measured. On the basis of these measurements, mass flow and rate of heat release are calculated. The rate of heat release is calculated according to the oxygen consumption principle. The upper limit for measurements is approximately 10 MW and the lower is 0.1 MW.
Christopher J. Fettig; Joel D. McMillin; John A. Anhold; Shakeeb M. Hamud; Robert R. Borys; Steven J. Seybold
2007-01-01
Selective logging, fire suppression, forest succession, and climatic changes have resulted in high fire hazards over large areas of the western USA. Federal and state hazardous fuel reduction programs have increased accordingly to reduce the risk, extent and severity of these events, particularly in the wildland urban interface. In this study, we examined the effect of...
Roger D. Ottmar; John I. Blake; William T. Crolly
2012-01-01
The inherent spatial and temporal heterogeneity of fuel beds in forests of the southeastern United States may require fine scale fuel measurements for providing reliable fire hazard and fuel treatment effectiveness estimates. In a series of five papers, an intensive, fine scale fuel inventory from the Savanna River Site in the southeastern United States is used for...
Wang, Bibo; Zhang, Yan; Tao, Youji; Zhou, Xia; Song, Lei; Jie, Ganxin; Hu, Yuan
2018-06-15
The current study aims at monitoring the role of the different natural environments on the physical properties and fire hazards of HIPS composites ageing in Turpan and Qionghai. The results indicated that the chromatic aberration and degradation of surface appearance intensified with the increasing ageing time. More flame retardants migrated and were eroded for HIPS composites ageing in Qionghai than those ageing in Turpan, which was caused by the combination of sunlight, high temperature and rainwater in Qionghai. After degradation in the natural environments, the HIPS composites possessed the lower thermal stability and char residues, more toxic gases release, higher peak heat release rate and fire hazard. For example, the peak heat release rate in Qionghai increased by 88.9%, which is much higher than that of in Turpan (55.6%). Moreover, the tensile strength and elongation at break decreased by 46% and 59% for HIPS composites ageing in Turpan and reduced by 53% and 67% for HIPS composites aged in Qionghai, respectively. The results demonstrate that more serious degradation of physical properties and higher fire hazard for HIPS composites ageing in Qionghai than those in Turpan due to the different natural ageing environments. Copyright © 2018 Elsevier B.V. All rights reserved.
Tara L Keyser; Fredrick W Smith; Wayne D. Shepperd
2009-01-01
We examined the impacts of post-fire salvage logging on regeneration, fuel accumulation, and understorey vegetation and assessed whether the effects of salvage logging differed between stands burned under moderate and high fire severity following the 2000 Jasper Fire in the Black Hills. In unsalvaged sites, fire-related tree mortality...
Response of Reptiles and Amphibians to Repeated Fuel Reduction Treatments
Charlotte E. Matthews; Christopher E. Moorman; Cathryn H. Greenberg; Thomas A. Waldrop
2010-01-01
Recent use of prescribed fire and fire surrogates to reduce fuel hazards has spurred interest in their effects on wildlife. Studies of fire in the southern Appalachian Mountains (USA) have documented few effects on reptiles and amphibians. However, these studies were conducted after only one fire and for only a short time (1â3 yr) after the fire. From mid-May to mid-...
Robert E. Keane; Matthew Rollins; Zhi-Liang Zhu
2007-01-01
Canopy and surface fuels in many fire-prone forests of the United States have increased over the last 70 years as a result of modern fire exclusion policies, grazing, and other land management activities. The Healthy Forest Restoration Act and National Fire Plan establish a national commitment to reduce fire hazard and restore fire-adapted ecosystems across the USA....
NASA Astrophysics Data System (ADS)
Cioca, Ionel-Lucian; Moraru, Roland Iosif
2012-10-01
In order to meet statutory requirements concerning the workers health and safety, it is necessary for mine managers within Valea Jiului coal basin in Romania to address the potential for underground fires and explosions and their impact on the workforce and the mine ventilation systems. Highlighting the need for a unified and systematic approach of the specific risks, the authors are developing a general framework for fire/explosion risk assessment in gassy mines, based on the quantification of the likelihood of occurrence and gravity of the consequences of such undesired events and employing Root-Cause analysis method. It is emphasized that even a small fire should be regarded as being a major hazard from the point of view of explosion initiation, should a combustible atmosphere arise. The developed methodology, for the assessment of underground fire and explosion risks, is based on the known underground explosion hazards, fire engineering principles and fire test criteria for potentially combustible materials employed in mines.
Cannon, Susan H.; Gartner, Joseph E.; Rupert, Michael G.; Michael, John A.
2010-01-01
This report presents an emergency assessment of potential debris-flow hazards from basins burned by the 2009 La Brea and Jesusita fires in Santa Barbara County, the Guiberson fire in Ventura County, the Morris fire in Los Angeles County, the Sheep, Oak Glen, and Pendleton fires in San Bernardino County, and the Cottonwood fire in Riverside County, southern California. Statistical-empirical models developed to analyze postfire debris flows are used to estimate the probability and volume of debris-flows produced from drainage basins within each of the burned areas. Debris-flow probabilities and volumes are estimated as functions of different measures of basin burned extent, gradient, and material properties in response to both a 3-hour-duration, 2-year-recurrence thunderstorm and to a widespread, 12-hour-duration, 2-year-recurrence winter storm. This assessment provides critical information for issuing warnings, locating and designing mitigation measures, and planning evacuation timing and routes within the first two winters following the fire.
Fire Detection Tradeoffs as a Function of Vehicle Parameters
NASA Technical Reports Server (NTRS)
Urban, David L.; Dietrich, Daniel L.; Brooker, John E.; Meyer, Marit E.; Ruff, Gary A.
2016-01-01
Fire survivability depends on the detection of and response to a fire before it has produced an unacceptable environment in the vehicle. This detection time is the result of interplay between the fire burning and growth rates; the vehicle size; the detection system design; the transport time to the detector (controlled by the level of mixing in the vehicle); and the rate at which the life support system filters the atmosphere, potentially removing the detected species or particles. Given the large differences in critical vehicle parameters (volume, mixing rate and filtration rate) the detection approach that works for a large vehicle (e.g. the ISS) may not be the best choice for a smaller crew capsule. This paper examines the impact of vehicle size and environmental control and life support system parameters on the detectability of fires in comparison to the hazard they present. A lumped element model was developed that considers smoke, heat, and toxic product release rates in comparison to mixing and filtration rates in the vehicle. Recent work has quantified the production rate of smoke and several hazardous species from overheated spacecraft polymers. These results are used as the input data set in the lumped element model in combination with the transport behavior of major toxic products released by overheating spacecraft materials to evaluate the necessary alarm thresholds to enable appropriate response to the fire hazard.
40 CFR 264.51 - Purpose and implementation of contingency plan.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND... plan must be designed to minimize hazards to human health or the environment from fires, explosions, or any unplanned sudden or non-sudden release of hazardous waste or hazardous waste constituents to air...
40 CFR 265.51 - Purpose and implementation of contingency plan.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) SOLID WASTES (CONTINUED) INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT... contingency plan must be designed to minimize hazards to human health or the environment from fires, explosions, or any unplanned sudden or non-sudden release of hazardous waste or hazardous waste constituents...
40 CFR 265.51 - Purpose and implementation of contingency plan.
Code of Federal Regulations, 2012 CFR
2012-07-01
...) SOLID WASTES (CONTINUED) INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT... contingency plan must be designed to minimize hazards to human health or the environment from fires, explosions, or any unplanned sudden or non-sudden release of hazardous waste or hazardous waste constituents...
40 CFR 265.51 - Purpose and implementation of contingency plan.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) SOLID WASTES (CONTINUED) INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT... contingency plan must be designed to minimize hazards to human health or the environment from fires, explosions, or any unplanned sudden or non-sudden release of hazardous waste or hazardous waste constituents...
40 CFR 264.51 - Purpose and implementation of contingency plan.
Code of Federal Regulations, 2012 CFR
2012-07-01
...) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND... plan must be designed to minimize hazards to human health or the environment from fires, explosions, or any unplanned sudden or non-sudden release of hazardous waste or hazardous waste constituents to air...
40 CFR 264.51 - Purpose and implementation of contingency plan.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND... plan must be designed to minimize hazards to human health or the environment from fires, explosions, or any unplanned sudden or non-sudden release of hazardous waste or hazardous waste constituents to air...
Jesse K. Kreye; J. Morgan Varner; Jeffrey M. Kane; Eric E. Knapp; Warren P. Reed
2016-01-01
Mastication of shrubs and small trees to reduce fire hazard has become a widespread management practice, yet many aspects of the fire behaviour of these unique woody fuelbeds remain poorly understood. To examine the effects of fuelbed aging on fire behaviour, we conducted laboratory burns with masticated Arctostaphylos spp. and Ceanothus...
Mike Battaglia; Frederick W. Smith; Wayne D. Shepperd
2009-01-01
Reduction of crown fire hazard in Pinus ponderosa forests in the Black Hills, SD, often focuses on the removal of overstorey trees to reduce crown bulk density. Dense ponderosa pine regeneration establishes several years after treatment and eventually increases crown fire risk if allowed to grow. Using prescribed fire to control this regeneration is...
75 FR 44720 - Safety Zone; Live-Fire Gun Exercise, M/V Del Monte, James River, VA
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-29
...-AA00 Safety Zone; Live-Fire Gun Exercise, M/V Del Monte, James River, VA AGENCY: Coast Guard, DHS... mariners from the hazards associated with live fire and explosive training events. DATES: This rule is... Hampton Roads was notified that the U.S. Navy will conduct a live fire and explosive training event...
Fuels planning: Managing forest structure to reduce fire hazard
David L. Peterson; Morris C. Johnson; James K. Agee; Theresa B. Jain; Donald McKenzie; Elizabeth D. Reinhardt
2003-01-01
Prior to the 20th century, low intensity fires burned regularly in most arid to semiarid forest ecosystems, with ignitions caused by lightning and humans (e.g., Baisan and Swetnam 1997, Allen et al. 2002, Hessl et al. 2004). Low intensity fires controlled regeneration of fire sensitive (e.g., grand fir [Abies grandis]) species (Arno and Allison-Bunnell 2002), promoted...
Reintroducing fire into the Blacks Mountain Research Natural Area: effects on fire hazard
Carl N. Skinner
2005-01-01
Frequent, low-intensity, surface fires were an integral ecological process in the Blacks Mountain Experimental Forest (BMEF) prior to the 20th Century. With rare exception, fires have been successfully excluded from BMEF since the early 1900s. The Blacks Mountain Research Natural Area (BMRNA) covers approximately 521 acres of BMEF in 5 compartments of approximately 100...
J. R. Miesel; R. E. J. Boerner; C. N. Skinner
2011-01-01
Forest thinning and prescribed fire are management strategies used to reduce hazardous fuel loads and catastrophic wildfires in western mixed-conifer forests. We evaluated effects of thinning (Thin) and prescribed fire (Burn), alone and in combination (Thin+Burn), on N transformations and microbial enzyme activities relative to an untreated control (Control) at 1 and 3...
Fire history, effects and management in southern Nevada [Chapter 5
Mathew L. Brooks; Jeanne C. Chambers; Randy A. McKinley
2013-01-01
Fire can be both an ecosystem stressor (Chapter 2) and a critical ecosystem process, depending on when, where, and under what conditions it occurs on the southern Nevada landscape. Fire can also pose hazards to human life and property, particularly in the wildland/urban interface (WUI). The challenge faced by land managers is to prevent fires from occurring where they...
Wang, Zhendi; Li, K; Lambert, P; Yang, Chun
2007-01-12
On 15 August 2001, a tire fire took place at the Pneu Lavoie Facility in Gatineau, Quebec, in which 4000 to 6000 new and recycled tires were stored along with other potentially hazardous materials. Comprehensive gas chromatography-mass spectrometry (GC-MS) analyses were performed on the tire fire samples to facilitate detailed chemical composition characterization of toxic polycyclic aromatic hydrocarbons (PAHs) and other organic compounds in samples. It is found that significant amounts of PAHs, particularly the high-ring-number PAHs, were generated during the fire. In total, 165 PAH compounds including 13 isomers of molecular weight (MW) 302, 10 isomers of MW 278, 10 isomers of MW 276, 7 isomers of MW 252, 7 isomers of MW 228, and 8 isomers of MW 216 PAHs were positively identified in the tire fire wipe samples for the first time. Numerous S-, O-, and N-containing PAH compounds were also detected. The identification and characterization of the PAH isomers was mainly based on: (1) a positive match of mass spectral data of the PAH isomers with the NIST authentic mass spectra database; (2) a positive match of the GC retention indices (I) of PAHs with authentic standards and with those reported in the literature; (3) agreement of the PAH elution order with the NIST (US National Institute of Standards and Technology) Standard Reference Material 1597 for complex mixture of PAHs from coal tar; (4) a positive match of the distribution patterns of PAH isomers in the SIM mode between the tire fire samples and the NIST Standard Reference Materials and well-characterized reference oils. Quantitation of target PAHs was done on the GC-MS in the selected ion monitoring (SIM) mode using the internal standard method. The relative response factors (RRF) for target PAHs were obtained from analyses of authentic PAH standard compounds. Alkylated PAH homologues were quantitated using straight baseline integration of each level of alkylation.
Assessing SaTScan ability to detect space-time clusters in wildfires
NASA Astrophysics Data System (ADS)
Costa, Ricardo; Pereira, Mário; Caramelo, Liliana; Vega Orozco, Carmen; Kanevski, Mikhail
2013-04-01
Besides classical cluster analysis techniques which are able to analyse spatial and temporal data, SaTScan software analyses space-time data using the spatial, temporal or space-time scan statistics. This software requires the spatial coordinates of the fire, but since in the Rural Fire Portuguese Database (PRFD) (Pereira et al, 2011) the location of each fire is the parish where the ignition occurs, the fire spatial coordinates were considered as coordinates of the centroid of the parishes. Moreover, in general, the northern region is characterized by a large number of small parishes while the southern comprises parish much larger. The objectives of this study are: (i) to test the ability of SaTScan to detect the correct space-time clusters, in what respects to spatial and temporal location and size; and, (ii) to evaluate the effect of the dimensions of the parishes and of aggregating all fires occurred in a parish in a single point. Results obtained with a synthetic database where clusters were artificially created with different densities, in different regions of the country and with different sizes and durations, allow to conclude: the ability of SaTScan to correctly identify the clusters (location, shape and spatial and temporal dimension); and objectively assess the influence of the size of the parishes and windows used in space-time detection. Pereira, M. G., Malamud, B. D., Trigo, R. M., and Alves, P. I.: The history and characteristics of the 1980-2005 Portuguese rural fire database, Nat. Hazards Earth Syst. Sci., 11, 3343-3358, doi:10.5194/nhess-11-3343-2011, 2011 This work is supported by European Union Funds (FEDER/COMPETE - Operational Competitiveness Programme) and by national funds (FCT - Portuguese Foundation for Science and Technology) under the project FCOMP-01-0124-FEDER-022692, the project FLAIR (PTDC/AAC-AMB/104702/2008) and the EU 7th Framework Program through FUME (contract number 243888).
Anne E. Black; Peter Landres
2011-01-01
Current fire policy to restore ecosystem function and resiliency and reduce buildup of hazardous fuels implies a larger future role for fire (both natural and human ignitions) (USDA and USDOI 2000). Yet some fire management (such as building fire line, spike camps, or heli-spots) potentially causes both short- and long-term impacts to forest health. In the short run,...
Petrakis, Roy; Villarreal, Miguel; Wu, Zhuoting; Hetzler, Robert; Middleton, Barry R.; Norman, Laura M.
2018-01-01
The practice of fire suppression across the western United States over the past century has led to dense forests, and when coupled with drought has contributed to an increase in large and destructive wildfires. Forest management efforts aimed at reducing flammable fuels through various fuel treatments can help to restore frequent fire regimes and increase forest resilience. Our research examines how different fuel treatments influenced burn severity and post-fire vegetative stand dynamics on the San Carlos Apache Reservation, in east-central Arizona, U.S.A. Our methods included the use of multitemporal remote sensing data and cloud computing to evaluate burn severity and post-fire vegetation conditions as well as statistical analyses. We investigated how forest thinning, commercial harvesting, prescribed burning, and resource benefit burning (managed wildfire) related to satellite measured burn severity (the difference Normalized Burn Ratio – dNBR) following the 2013 Creek Fire and used spectral measures of post-fire stand dynamics to track changes in land surface characteristics (i.e., brightness, greenness and wetness). We found strong negative relationships between dNBR and post-fire greenness and wetness, and a positive non-linear relationship between dNBR and brightness, with greater variability at higher severities. Fire severity and post-fire surface changes also differed by treatment type. Our results showed harvested and thinned sites that were not treated with prescribed fire had the highest severity fire. When harvesting was followed by a prescribed burn, the sites experienced lower burn severity and reduced post-fire changes in vegetation greenness and wetness. Areas that had previously experienced resource benefit burns had the lowest burn severities and the highest post-fire greenness measurements compared to all other treatments, except for where the prescribed burn had occurred. These results suggest that fire treatments may be most effective at reducing the probability of hazardous fire and increasing post-fire recovery. This research demonstrates the utility of remote sensing and spatial data to inform forest management, and how various fuel treatments can influence burn severity and post-fire vegetation response within ponderosa pine forests across the southwestern U.S.
A Mobile Robot for Remote Response to Incidents Involving Hazardous Materials
NASA Technical Reports Server (NTRS)
Welch, Richard V.
1994-01-01
This paper will describe a teleoperated mobile robot system being developed at JPL for use by the JPL Fire Department/HAZMAT Team. The project, which began in October 1990, is focused on prototyping a robotic vehicle which can be quickly deployed and easily operated by HAZMAT Team personnel allowing remote entry and exploration of a hazardous material incident site. The close involvement of JPL Fire Department personnel has been critical in establishing system requirements as well as evaluating the system. The current robot, called HAZBOT III, has been especially designed for operation in environments that may contain combustible gases. Testing of the system with the Fire Department has shown that teleoperated robots can successfully gain access to incident sites allowing hazardous material spills to be remotely located and identified. Work is continuing to enable more complex missions through enhancement of the operator interface and by allowing tetherless operation.
Modeling the Risk of Fire/Explosion Due to Oxidizer/Fuel Leaks in the Ares I Interstage
NASA Technical Reports Server (NTRS)
Ring, Robert W.; Stott, James E.; Hales, Christy
2008-01-01
A significant flight hazard associated with liquid propellants, such as those used in the upper stage of NASA's new Ares I launch vehicle, is the possibility of leakage of hazardous fluids resulting in a catastrophic fire/explosion. The enclosed and vented interstage of the Ares I contains numerous oxidizer and fuel supply lines as well as ignition sources. The potential for fire/explosion due to leaks during ascent depends on the relative concentrations of hazardous and inert fluids within the interstage along with other variables such as pressure, temperature, leak rates, and fluid outgasing rates. This analysis improves on previous NASA Probabilistic Risk Assessment (PRA) estimates of the probability of deflagration, in which many of the variables pertinent to the problem were not explicitly modeled as a function of time. This paper presents the modeling methodology developed to analyze these risks.
Determination of Particular Endogenous Fires Hazard Zones in Goaf with Caving of Longwall
NASA Astrophysics Data System (ADS)
Tutak, Magdalena; Brodny, Jaroslaw
2017-12-01
Hazard of endogenous fires is one of the basic and common presented occupational safety hazards in coal mine in Poland and in the world. This hazard means possibility of coal self-ignition as the result of its self-heating process in mining heading or its surrounding. In underground coal-mining during ventilating of operating longwalls takes place migration of parts of airflow to goaf with caving. In a case when in these goaf a coal susceptible to selfignition occurs, then the airflow through these goaf may influence on formation of favourable conditions for coal oxidation and subsequently to its self-heating and self-ignition. Endogenous fire formed in such conditions can pose a serious hazard for the crew and for continuity of operation of mining plant. From the practical point of view, a very significant meaning has determination of the zone in the goaf with caving, in which necessary conditions for occurrence of endogenous fire are fulfilled. In the real conditions determination of such a zone is practically impossible. Therefore, authors of paper developed a methodology of determination of this zone basing on the results of modelling tests. This methodology includes a development of model of tested area, determination of boundary conditions and carrying out the simulation calculations. Based on the obtained results particular hazardous zone of endogenous fire is determined. A base for development of model of investigated region and selection of boundary conditions are the results of real tests. In the paper fundamental assumption of developed methodology, particularly in a range of assumed hazard criterion and sealing coefficient of goaf with caving were discussed. Also a mathematical model of gas flow through the porous media was characterized. Example of determination of a zone particularly endangered by endogenous fire for real system of mining heading in one of the hard coal mine was presented. Longwall ventilated in the „Y” system was subjected to the tests. For determined mining-geological conditions, the critical value of velocity of airflow and oxygen concentration in goaf, conditioning initiation of coal oxidation process were determined. For calculations ANSYS Fluent software based on finite volume method, which enable very precisely to determine the physical and chemical air and parameters at any point of tested mining heading and goaf with caving was used. Such precisely determination of these parameters on the base of the test in real conditions is practically impossible. Obtained results allowed to take early proper actions in order to limit the occurrence of endogenous fire. One can conclude, that presented methodology creates great possibilities of practical application of modelling tests for improvement of the occupational safety state in mine.
29 CFR 1910.39 - Fire prevention plans.
Code of Federal Regulations, 2010 CFR
2010-07-01
... OCCUPATIONAL SAFETY AND HEALTH STANDARDS Means of Egress § 1910.39 Fire prevention plans. (a) Application. An.... A fire prevention plan must be in writing, be kept in the workplace, and be made available to... employees responsible for the control of fuel source hazards. (d) Employee information. An employer must...
40 CFR 63.10000 - What are my general requirements for complying with this subpart?
Code of Federal Regulations, 2014 CFR
2014-07-01
... SOURCE CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants: Coal- and Oil... of startup and shutdown; however, for coal-fired, liquid oil-fired, or solid oil-derived fuel-fired... associated air pollution control equipment and monitoring equipment, in a manner consistent with safety and...
40 CFR 63.10000 - What are my general requirements for complying with this subpart?
Code of Federal Regulations, 2013 CFR
2013-07-01
... SOURCE CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants: Coal- and Oil... of startup and shutdown; however, for coal-fired, liquid oil-fired, or solid oil-derived fuel-fired... associated air pollution control equipment and monitoring equipment, in a manner consistent with safety and...
32 CFR 632.5 - Use of firearms.
Code of Federal Regulations, 2010 CFR
2010-07-01
... not fire if shots are likely to harm innocent bystanders. (3) Since warning shots could harm innocent bystanders, avoid firing them. However, when lesser degrees of force have failed, the law enforcement or.... If able to avoid hazards to innocent persons in these cases, fire warning shots. (4) Aim to disable...
Prescribed fire in upland harwood forests
T.L. Keyser; C.H. Greenberg; H. McNab
2014-01-01
In upland hardwood forests of the Southeastern U.S.,prescribed fire is increasingly used by land managers citing objectives that include hazardous fuels reduction, wildlife habitat improvement, promoting oak regeneration, or restoring forest composition or structure to an historic condition. Research suggests that prescribed fire effects on hardwood forests and...
How to reduce your fire insurance rates
NASA Technical Reports Server (NTRS)
Dubain, M.
1971-01-01
Construction procedures and utilization of materials to reduce the cost of insuring large buildings against losses from fire are discussed. Examples of good and bad techniques in building construction and fire safety management are provided. The inadequacies of building codes and the hazards resulting from improper construction are examined.
Fire management of California shrubland landscapes
Keeley, Jon E.
2002-01-01
Fire management of California shrublands has been heavily influenced by policies designed for coniferous forests, however, fire suppression has not effectively excluded fire from chaparral and coastal sage scrub landscapes and catastrophic wildfires are not the result of unnatural fuel accumulation. There is no evidence that prescribed burning in these shrublands provides any resource benefit and in some areas may negatively impact shrublands by increasing fire frequency. Therefore, fire hazard reduction is the primary justification for prescription burning, but it is doubtful that rotational burning to create landscape age mosaics is a cost effective method of controlling catastrophic wildfires. There are problems with prescription burning in this crown-fire ecosystem that are not shared by forests with a natural surface-fire regime. Prescription weather conditions preclude burning at rotation intervals sufficient to effect the control of fires ignited under severe weather conditions. Fire management should focus on strategic placement of prescription burns to both insure the most efficient fire hazard reduction and to minimize the amount of landscape exposed to unnaturally high fire frequency. A major contributor to increased fire suppression costs and increased loss of property and lives is the continued urban sprawl into wildlands naturally subjected to high intensity crown fires. Differences in shrubland fire history suggest there may be a need for different fire management tactics between central coastal and southern California. Much less is known about shrubland fire history in the Sierra Nevada foothills and interior North Coast Ranges, and thus it would be prudent to not transfer these ideas too broadly across the range of chaparral until we have a clearer understanding of the extent of regional variation in shrubland fire regimes.
Fire management of California shrubland landscapes.
Keeley, Jon E
2002-03-01
Fire management of California shrublands has been heavily influenced by policies designed for coniferous forests, however, fire suppression has not effectively excluded fire from chaparral and coastal sage scrub landscapes and catastrophic wildfires are not the result of unnatural fuel accumulation. There is no evidence that prescribed burning in these shrublands provides any resource benefit and in some areas may negatively impact shrublands by increasing fire frequency. Therefore, fire hazard reduction is the primary justification for prescription burning, but it is doubtful that rotational burning to create landscape age mosaics is a cost effective method of controlling catastrophic wildfires. There are problems with prescription burning in this crown-fire ecosystem that are not shared by forests with a natural surface-fire regime. Prescription weather conditions preclude burning at rotation intervals sufficient to effect the control of fires ignited under severe weather conditions. Fire management should focus on strategic placement of prescription burns to both insure the most efficient fire hazard reduction and to minimize the amount of landscape exposed to unnaturally high fire frequency. A major contributor to increased fire suppression costs and increased loss of property and lives is the continued urban sprawl into wildlands naturally subjected to high intensity crown fires. Differences in shrubland fire history suggest there may be a need for different fire management tactics between central coastal and southern California. Much less is known about shrubland fire history in the Sierra Nevada foothills and interior North Coast Ranges, and thus it would be prudent to not transfer these ideas too broadly across the range of chaparral until we have a clearer understanding of the extent of regional variation in shrubland fire regimes.
Code of Federal Regulations, 2013 CFR
2013-01-01
... value of the collateral or the amount of the loan. Hazard insurance includes fire, windstorm, lightning... Regulations of the Department of Agriculture (Continued) RURAL BUSINESS-COOPERATIVE SERVICE AND RURAL... Insurance. (a) Hazard. Hazard insurance with a standard mortgage clause naming the lender as beneficiary...
Code of Federal Regulations, 2012 CFR
2012-01-01
... value of the collateral or the amount of the loan. Hazard insurance includes fire, windstorm, lightning... Regulations of the Department of Agriculture (Continued) RURAL BUSINESS-COOPERATIVE SERVICE AND RURAL... Insurance. (a) Hazard. Hazard insurance with a standard mortgage clause naming the lender as beneficiary...
Code of Federal Regulations, 2014 CFR
2014-01-01
... value of the collateral or the amount of the loan. Hazard insurance includes fire, windstorm, lightning... Regulations of the Department of Agriculture (Continued) RURAL BUSINESS-COOPERATIVE SERVICE AND RURAL... Insurance. (a) Hazard. Hazard insurance with a standard mortgage clause naming the lender as beneficiary...
Code of Federal Regulations, 2011 CFR
2011-01-01
... value of the collateral or the amount of the loan. Hazard insurance includes fire, windstorm, lightning... Regulations of the Department of Agriculture (Continued) RURAL BUSINESS-COOPERATIVE SERVICE AND RURAL... Insurance. (a) Hazard. Hazard insurance with a standard mortgage clause naming the lender as beneficiary...
The dynamics and drivers of fuel and fire in the Portuguese public forest.
Fernandes, Paulo M; Loureiro, Carlos; Guiomar, Nuno; Pezzatti, Gianni B; Manso, Filipa T; Lopes, Luís
2014-12-15
The assumption that increased wildfire incidence in the Mediterranean Basin during the last decades is an outcome of changes in land use warrants an objective analysis. In this study we examine how annual area burned (BA) in the Portuguese public forest varied in relation to environmental and human-influenced drivers during the 1943-2011 period. Fire behaviour models were used to describe fuel hazard considering biomass removal, cover type changes, area burned, post-disturbance fuel accumulation, forest age-classes distribution and fuel connectivity. Biomass removal decreased rapidly beyond the 1940s, which, along with afforestation, increased fuel hazard until the 1980s; a subsequent decline was caused by increased fire activity. Change point analysis indicates upward shifts in BA in 1952 and in 1973, both corresponding to six-fold increases. Fire weather (expressed by the 90th percentile of the Canadian FWI during summer) increased over the study period, accounting for 18 and 36% of log(BA) variation before 1974 and after 1973, respectively. Regression modelling indicates that BA responds positively to fire weather, fuel hazard and number of fires in descending order of importance; pre-summer and 2-year lagged precipitation respectively decrease and increase BA, but the effects are minor and non-significant when both variables are included in the model. Land use conflicts (expressed through more fires) played a role, but it was afforestation and agricultural abandonment that supported the fire regime shifts, explaining weather-drought as the current major driver of BA as well. We conclude that bottom-up factors, i.e. human-induced changes in landscape flammability and ignition density, can enhance or override the influence of weather-drought on the fire regime in Mediterranean humid regions. A more relevant role of fuel control in fire management policies and practices is warranted by our findings. Copyright © 2014 Elsevier Ltd. All rights reserved.
Liaw, Horng-Jang; Wang, Tzu-Ai
2007-03-06
Flash point is one of the major quantities used to characterize the fire and explosion hazard of liquids. Herein, a liquid with dissolved salt is presented in a salt-distillation process for separating close-boiling or azeotropic systems. The addition of salts to a liquid may reduce fire and explosion hazard. In this study, we have modified a previously proposed model for predicting the flash point of miscible mixtures to extend its application to solvent/salt mixtures. This modified model was verified by comparison with the experimental data for organic solvent/salt and aqueous-organic solvent/salt mixtures to confirm its efficacy in terms of prediction of the flash points of these mixtures. The experimental results confirm marked increases in liquid flash point increment with addition of inorganic salts relative to supplementation with equivalent quantities of water. Based on this evidence, it appears reasonable to suggest potential application for the model in assessment of the fire and explosion hazard for solvent/salt mixtures and, further, that addition of inorganic salts may prove useful for hazard reduction in flammable liquids.
Phasic spike patterning in rat supraoptic neurones in vivo and in vitro
Sabatier, Nancy; Brown, Colin H; Ludwig, Mike; Leng, Gareth
2004-01-01
In vivo, most vasopressin cells of the hypothalamic supraoptic nucleus fire action potentials in a ‘phasic’ pattern when the systemic osmotic pressure is elevated, while most oxytocin cells fire continuously. The phasic firing pattern is believed to arise as a consequence of intrinsic activity-dependent changes in membrane potential, and these have been extensively studied in vitro. Here we analysed the discharge patterning of supraoptic nucleus neurones in vivo, to infer the characteristics of the post-spike sequence of hyperpolarization and depolarization from the observed spike patterning. We then compared patterning in phasic cells in vivo and in vitro, and we found systematic differences in the interspike interval distributions, and in other statistical parameters that characterized activity patterns within bursts. Analysis of hazard functions (probability of spike initiation as a function of time since the preceding spike) revealed that phasic firing in vitro appears consistent with a regenerative process arising from a relatively slow, late depolarizing afterpotential that approaches or exceeds spike threshold. By contrast, in vivo activity appears to be dominated by stochastic rather than deterministic mechanisms, and appears consistent with a relatively early and fast depolarizing afterpotential that modulates the probability that random synaptic input exceeds spike threshold. Despite superficial similarities in the phasic firing patterns observed in vivo and in vitro, there are thus fundamental differences in the underlying mechanisms. PMID:15146047
Smouldering peat fires in polluted landscapes and their impact on heavy metal mobilisation
NASA Astrophysics Data System (ADS)
Clay, Gareth; Rothwell, James; Shuttleworth, Emma
2016-04-01
Whilst wildfires are commonly viewed as a threat confined to Southern Europe, Australia, and North America, recognition of wildfire hazard in the UK has been growing in recent years. UK wildfires often occur on heathland vegetation underlain by peat. These areas can contain industrially-derived legacy pollutants, such as mercury, lead, and arsenic. Ignition of the peat can lead to long-term smouldering fires that are difficult to extinguish, leading to large-scale damage. While work on assessing post-fire damage of peatlands has focussed on carbon and nutrient dynamics, there has been little attention on the release of heavy metals following wildfires. This paper presents initial data from a preliminary study to assess heavy metal release from smouldering peat fires. A homogenised sample of peat from the Peak District National Park, UK was ignited, monitored using thermocouples and an IR camera, and left to smoulder until self-extinguished (~9 hours). Total mass loss was 61%. Samples of pre- and post-burn peat were analysed for their heavy metal concentrations using XRF, ICP-MS, and CVAFS. Sample analysis is ongoing, but initial data shows that there is a substantial (3x) relative enrichment in heavy metal concentrations in post-fire ash. This has important implications for subsequent mobilisation in the aquatic and terrestrial environments, as well as consequences for human health risk through atmospheric redistribution.
Economic Impact Analyses of Interdisciplinary Multi-hazard Scenarios: ShakeOut and ARkStorm
NASA Astrophysics Data System (ADS)
Wein, A. M.; Rose, A.; Sue Wing, I.; Wei, D.
2011-12-01
U. S. Geological Survey (USGS) scientists are using an interdisciplinary strategy to develop and analyze multi-hazard scenarios to help communities enhance resilience to natural hazard disasters. Two such scenarios are the southern California ShakeOut earthquake and the California ARkStorm winter storm. Both scenarios are multi-hazard: Shakeout ground motions trigger landslides and liquefaction and ARkStorm involves wind, flood, landslide, and coastal hazards. A collaborative scenario-process engages partners and stakeholders throughout the development and use of the scenarios, In doing so, community resilience is enhanced by educating communities about hazards and hazard interdependencies, building networks from scientists to decision makers, exercising emergency management strategies, identifying emergency management issues, and motivating solutions prior to an event. In addition, interdisciplinary scenarios stimulate research on the various steps of analysis (e.g., natural hazard processes, physical damages, societal consequences, and policy connections). In particular, USGS scientists have collaborated with economists to advance methods to estimate the economic impacts (business interruption losses) of disasters. Our economic impact analyses evolved from the economic module in the Federal Emergency Management Agency's loss-estimation tool, HAZUS-MH, to a more encompassing input-output analysis for ShakeOut, to a more sophisticated Computable General Equilibrium model for ARkStorm. The analyses depend on physical damage and restoration time estimates from engineers and geographic analyses of economic assets in hazard zones. Economic resilience strategies are incorporated to represent resourcefulness and ingenuity that avoids potential losses during and after an event. Such strategies operate at three levels of the economy: micro (e.g., ability to catch up on lost production time), meso (e.g., coordination within a sector to share resources), and macro (e.g., price adjustments to redistribute scarce resources). A sensitivity analysis of the ARkStorm economic impact model explores the effects of 1) the magnitude of the shocks (e.g., flood damages to buildings and infrastructure, agricultural productivity, and lifeline service disruptions), 2) the sustainability of the economic resilience strategies, and 3) the amount, timing, and source of reconstruction funds. The inclusion of an economic analysis in ShakeOut and ARkStorm broadens the range of interest in the scenario results. For example, the relative contribution of ShakeOut economic shocks to business interruption losses emphasized the need to reduce the impacts of fire following earthquake and water service disruption. Based on the magnitude and duration of the economic impacts for the ARkStorm scenario, policy experts surmised that business interruption policy time elements would be exceeded and business interruptions would be largely unfunded calling attention to the need for innovative funding solutions. Finally, economic impact analyses inform the question of paying now to mitigate or paying more later to recover.
A review of fire effects on bats and bat habitat in the eastern oaks region
Roger W. Perry
2012-01-01
Fire is increasingly being used in oak forests to promote oak regeneration, improve wildlife habitat, and reduce hazardous fuel loads. Although recent research has begun to shed light on the relationships among fire, bats, and bat habitat, these interactions are not yet fully understood. Fire may affect bats directly through heat and smoke during the burning process or...
A review of fire effects on bats and bat habitat in the eastern oak region
Roger W. Perry
2012-01-01
Fire is increasingly being used in oak forests to promote oak regeneration, improve wildlife habitat, and reduce hazardous fuel loads. Although recent research has begun to shed light on the relationships among fire, bats, and bat habitat, these interactions are not yet fully understood. Fire may affect bats directly through heat and smoke during the burning process or...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xiong, Yongliang; Wang, Yifeng
A method of removing a target gas from a gas stream is disclosed. The method uses advanced, fire-resistant activated carbon compositions having vastly improved fire resistance. Methods for synthesizing the compositions are also provided. The advanced compositions have high gas adsorption capacities and rapid adsorption kinetics (comparable to commercially-available activated carbon), without having any intrinsic fire hazard.
Regional estimation of current and future forest biomass
R.A. Mickler; T.S. Earnhardt; J.A. Moore
2002-01-01
The 90,674 wildland fires that burned 2.9 million ha at an estimated suppression cost of $1.6 billion in the United States during the 2000 fire season demonstrated that forest fuel loading has become a hazard to life, property, and ecosystem health as a result of past fire exclusion policies and practices. The fire regime at any given location in these regions is a...
Fire history, effects, and management in southern Nevada [Chapter 5] (Executive Summary)
Matthew L. Brooks; Jeanne C. Chambers; Randy A. McKinley
2013-01-01
Fire can be both an ecosystem stressor and a critical ecosystem process, depending on when, where, and under what conditions it occurs on the southern Nevada landscape. Fire can also pose hazards to human life and property, particularly in the wildland/ urban interface (WUI). The challenge faced by land managers is to prevent fires from occurring where they are likely...
Canadian Wildland Fire Strategy Project Management Team
2006-01-01
The Canadian Wildland Fire Strategy (CWFS) provides a vision for a new, innovative, and integrated approach to wildland fire management in Canada. It was developed under the auspices of the Canadian Council of Forest Ministers and seeks to balance the social, ecological, and economic aspects of wildland fire through a risk management framework that emphasizes hazard...
Modern Approaches to Wildfire Mitigation by Air and by Ground: An Interdisciplinary Perspective
NASA Astrophysics Data System (ADS)
Duffin, J.; Lindquist, E.; Pierce, J. L.; Wuerzer, T.; Lawless, B.; McCoy, J.
2013-12-01
In 2012, 1.7 million acres of land burned in Idaho--more than any other state. Boise, Idaho, is situated at the base of the Boise Foothills; this physiographic setting places the area at risk of not only fires along on the Wildland-Urban Interface (WUI), but also at risk for post-fire floods and debris flows in the lower lying neighborhoods adjacent to steep hillslopes. In 1959 and 1994, fires and post-fire debris flows devastated areas of the foothills, and inundated residences with water and mud. Anthropogenically-induced climate change is projected to increased summer temperatures and decrease summer precipitation; the associated increase in fire risk necessitates enhanced wildfire planning in Boise's WUI. Temporal uncertainty with varying weather and vegetation conditions poses problems in defining wildfire risk and requires new methods to address the WUI challenges. Unmanned aerial systems (UAS) could identify and characterize fire hazards to be mapped and used as a management tool. This technology would allow for repeat flights to update risk analysis as the hazards change both annually and multiple times within each fire season. With aerial photography obtained from flights, Structure from Motion software can be used to compile the images and render a 3D model to help quantify biomass. Aerial photographs would also allow for the ability to track seasonal changes in fire risk from vegetation height and inferred moisture content. Boise State University's departments of Geoscience, Community and Regional Planning, and the Public Policy Center are examining the risks and impacts of fire along the Boise WUI. The research integrates the perspectives of the geosciences and social sciences by combining physically-based fire hazards, effective fire management policies, and urban/regional planning in the WUI to provide better spatially-appropriate data and resources to the community and a common reference to assist in unifying the local efforts for fire mitigation. This presentation will introduce findings from a homeowner's survey of potentially at-risk residents regarding their perceptions of risk and uncertainty and their receptiveness to local mitigation, adaptation policies, and alternatives.
RAPID-N: Assessing and mapping the risk of natural-hazard impact at industrial installations
NASA Astrophysics Data System (ADS)
Girgin, Serkan; Krausmann, Elisabeth
2015-04-01
Natural hazard-triggered technological accidents (so-called Natech accidents) at hazardous installations can have major consequences due to the potential for release of hazardous materials, fires and explosions. Effective Natech risk reduction requires the identification of areas where this risk is high. However, recent studies have shown that there are hardly any methodologies and tools that would allow authorities to identify these areas. To work towards closing this gap, the European Commission's Joint Research Centre has developed the rapid Natech risk assessment and mapping framework RAPID-N. The tool, which is implemented in an online web-based environment, is unique in that it contains all functionalities required for running a full Natech risk analysis simulation (natural hazards severity estimation, equipment damage probability and severity calculation, modeling of the consequences of loss of containment scenarios) and for visualizing its results. The output of RAPID-N are risk summary reports and interactive risk maps which can be used for decision making. Currently, the tool focuses on Natech risk due to earthquakes at industrial installations. However, it will be extended to also analyse and map Natech risk due to floods in the near future. RAPID-N is available at http://rapidn.jrc.ec.europa.eu. This presentation will discuss the results of case-study calculations performed for selected flammable and toxic substances to test the capabilities of RAPID-N both for single- and multi-site earthquake Natech risk assessment. For this purpose, an Istanbul earthquake scenario provided by the Turkish government was used. The results of the exercise show that RAPID-N is a valuable decision-support tool that assesses the Natech risk and maps the consequence end-point distances. These end-point distances are currently defined by 7 kPa overpressure for Vapour Cloud Explosions, 2nd degree burns for pool fire (which is equivalent to a heat radiation of 5 kW/m2 for 40s), or the ERPG-2 concentration for atmospheric dispersion of toxic substances).
Fire and explosion hazards related to the industrial use of potassium and sodium methoxides.
Kwok, Q; Acheson, B; Turcotte, R; Janès, A; Marlair, G
2013-04-15
Sodium and potassium methoxides are used as an intermediary for a variety of products in several industrial applications. For example, current production of so called "1G-biodiesel" relies on processing a catalytic reaction called "transesterification". This reaction transforms lipid resources from biomass materials into fatty acid methyl and ethyl esters. 1-G biodiesel processes imply the use of methanol, caustic potash (KOH), and caustic soda (NaOH) for which the hazards are well characterized. The more recent introduction of the direct catalysts CH3OK and CH3ONa may potentially introduce new process hazards. From an examination of existing MSDSs concerning these products, it appears that no consensus currently exists on their intrinsic hazardous properties. Recently, l'Institut National de l'Environnement Industriel et des Risques (France) and the Canadian Explosives Research Laboratory (Canada) have embarked upon a joint effort to better characterize the thermal hazards associated with these catalysts. This work employs the more conventional tests for water reactivity as an ignition source, fire and dust explosion hazards, using isothermal nano-calorimetry, isothermal basket tests, the Fire Propagation Apparatus and a standard 20 L sphere, respectively. It was found that these chemicals can become self-reactive close to room temperature under specific conditions and can generate explosible dusts. Copyright © 2013 Crown. Published by Elsevier B.V. All rights reserved.
Remote Sensing of Chaparral Fire Potential: Case Study in Topanga Canyon, California.
Remote sensing techniques, especially the use of color infrared aerial photography, provide a useful tool for fire hazard analysis, including interpetive information about fuel volumes, physiognomic plant groupings, the relationships of buildings to both natural and planted vegetation, and fire vulnerability of roofing materials. In addition, the behavior of the September, 1970 Wright Fire in the Topanga study area suggested the validity of the fire potential analysis which had been made prior to that conflagration.
1990-11-01
radioactive) - Determine class of HAZMAT (Class A Explosive, Class B Explosive, Class C Explosive, Blasting Agent , Flammable Gas , Non- flammable Gas ... agent . Specific health and safety plans related to IRP actions amy be obtained from the same source. 2. Interaction of Fire Departments with the...such as digging near a gas line, a fuel tank, or buried explo- sives, the fire department would be briefed before beginning the work, and, under
Kenneth E. Skog; Peter J. Ince; Henry Spelter; Andi Kramp; R. James Barbour
2008-01-01
Part I of this paper identifies timberland areas in 12 western states where thinning treatments are judged to be needed to reduce fire hazard and may ?pay for themselves?? at a scale to make investment in forest product processing a realistic option. We also estimate amounts of biomass removed and costs of removal. Part II of this paper estimates the market impact if...
Strata-based forest fuel classification for wild fire hazard assessment using terrestrial LiDAR
NASA Astrophysics Data System (ADS)
Chen, Yang; Zhu, Xuan; Yebra, Marta; Harris, Sarah; Tapper, Nigel
2016-10-01
Fuel structural characteristics affect fire behavior including fire intensity, spread rate, flame structure, and duration, therefore, quantifying forest fuel structure has significance in understanding fire behavior as well as providing information for fire management activities (e.g., planned burns, suppression, fuel hazard assessment, and fuel treatment). This paper presents a method of forest fuel strata classification with an integration between terrestrial light detection and ranging (LiDAR) data and geographic information system for automatically assessing forest fuel structural characteristics (e.g., fuel horizontal continuity and vertical arrangement). The accuracy of fuel description derived from terrestrial LiDAR scanning (TLS) data was assessed by field measured surface fuel depth and fuel percentage covers at distinct vertical layers. The comparison of TLS-derived depth and percentage cover at surface fuel layer with the field measurements produced root mean square error values of 1.1 cm and 5.4%, respectively. TLS-derived percentage cover explained 92% of the variation in percentage cover at all fuel layers of the entire dataset. The outcome indicated TLS-derived fuel characteristics are strongly consistent with field measured values. TLS can be used to efficiently and consistently classify forest vertical layers to provide more precise information for forest fuel hazard assessment and surface fuel load estimation in order to assist forest fuels management and fire-related operational activities. It can also be beneficial for mapping forest habitat, wildlife conservation, and ecosystem management.
14 CFR 139.321 - Handling and storing of hazardous substances and materials.
Code of Federal Regulations, 2014 CFR
2014-01-01
...) Public protection. (3) Control of access to storage areas. (4) Fire safety in fuel farm and storage areas. (5) Fire safety in mobile fuelers, fueling pits, and fueling cabinets. (6) Training of fueling personnel in fire safety in accordance with paragraph (e) of this section. Such training at Class III...
14 CFR 139.321 - Handling and storing of hazardous substances and materials.
Code of Federal Regulations, 2011 CFR
2011-01-01
...) Public protection. (3) Control of access to storage areas. (4) Fire safety in fuel farm and storage areas. (5) Fire safety in mobile fuelers, fueling pits, and fueling cabinets. (6) Training of fueling personnel in fire safety in accordance with paragraph (e) of this section. Such training at Class III...
14 CFR 139.321 - Handling and storing of hazardous substances and materials.
Code of Federal Regulations, 2010 CFR
2010-01-01
...) Public protection. (3) Control of access to storage areas. (4) Fire safety in fuel farm and storage areas. (5) Fire safety in mobile fuelers, fueling pits, and fueling cabinets. (6) Training of fueling personnel in fire safety in accordance with paragraph (e) of this section. Such training at Class III...
14 CFR 139.321 - Handling and storing of hazardous substances and materials.
Code of Federal Regulations, 2013 CFR
2013-01-01
...) Public protection. (3) Control of access to storage areas. (4) Fire safety in fuel farm and storage areas. (5) Fire safety in mobile fuelers, fueling pits, and fueling cabinets. (6) Training of fueling personnel in fire safety in accordance with paragraph (e) of this section. Such training at Class III...
14 CFR 139.321 - Handling and storing of hazardous substances and materials.
Code of Federal Regulations, 2012 CFR
2012-01-01
...) Public protection. (3) Control of access to storage areas. (4) Fire safety in fuel farm and storage areas. (5) Fire safety in mobile fuelers, fueling pits, and fueling cabinets. (6) Training of fueling personnel in fire safety in accordance with paragraph (e) of this section. Such training at Class III...
REGIONAL ESTIMATION OF CURRENT AND FUTURE FOREST BIOMASS. (R828785)
The 90,674 wildland fires that burned 2.9 million ha at an estimated suppression cost of $1.6 billion in the United States during the 2000 fire season demonstrated that forest fuel loading has become a hazard to life, property, and ecosystem health as a result of past fire exc...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-19
... Coal- and Oil-Fired Electric Utility Steam Generating Units and Standards of Performance for Fossil... Units and Standards of Performance for Fossil-Fuel-Fired Electric Utility, Industrial-Commercial... before March 1, 2005, means a 24-hour period during which fossil fuel is combusted in a steam-generating...
40 CFR 63.10000 - What are my general requirements for complying with this subpart?
Code of Federal Regulations, 2012 CFR
2012-07-01
... Administrator which may include, but is not limited to, monitoring results, review of operation and maintenance... SOURCE CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants: Coal- and Oil... of startup and shutdown; however, for coal-fired, liquid oil-fired, or solid oil-derived fuel-fired...
Jesse K. Kreye; Leda N. Kobziar; Wayne C. Zipperer
2013-01-01
Mechanical fuels treatments are being used in fire-prone ecosystems where fuel loading poses a hazard, yetlittle research elucidating subsequent fire behaviour exists, especially in litter-dominated fuelbeds. To address this deficiency, we burned constructed fuelbeds from masticated sites in pine flatwoods forests in northern Florida...
46 CFR 147.65 - Carbon dioxide and halon fire extinguishing systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 5 2011-10-01 2011-10-01 false Carbon dioxide and halon fire extinguishing systems. 147.65 Section 147.65 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DANGEROUS CARGOES HAZARDOUS SHIPS' STORES Stowage and Other Special Requirements for Particular Materials § 147.65 Carbon dioxide and halon fire extinguishing...
46 CFR 147.65 - Carbon dioxide and halon fire extinguishing systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 5 2013-10-01 2013-10-01 false Carbon dioxide and halon fire extinguishing systems. 147.65 Section 147.65 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DANGEROUS CARGOES HAZARDOUS SHIPS' STORES Stowage and Other Special Requirements for Particular Materials § 147.65 Carbon dioxide and halon fire extinguishing...
46 CFR 147.65 - Carbon dioxide and halon fire extinguishing systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 5 2012-10-01 2012-10-01 false Carbon dioxide and halon fire extinguishing systems. 147.65 Section 147.65 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DANGEROUS CARGOES HAZARDOUS SHIPS' STORES Stowage and Other Special Requirements for Particular Materials § 147.65 Carbon dioxide and halon fire extinguishing...
Preventing disaster: Home ignitability in the wildland-urban interface
Jack D. Cohen
2000-01-01
Wildland-urban interface (W-UI) fires are a significant concern for federal, state, and local land management and fire agencies. Research using modeling, experiments, and W-UI case studies indicates that home ignitability during wildland fires depends on the characteristics of the home and its immediate surroundings. These findings have implications for hazard...
Fire behavior of halogen-free flame retardant electrical cables with the cone calorimeter.
Meinier, Romain; Sonnier, Rodolphe; Zavaleta, Pascal; Suard, Sylvain; Ferry, Laurent
2018-01-15
Fires involving electrical cables are one of the main hazards in Nuclear Power Plants (NPPs). Cables are complex assemblies including several polymeric parts (insulation, bedding, sheath) constituting fuel sources. This study provides an in-depth characterization of the fire behavior of two halogen-free flame retardant cables used in NPPs using the cone calorimeter. The influence of two key parameters, namely the external heat flux and the spacing between cables, on the cable fire characteristics is especially investigated. The prominent role of the outer sheath material on the ignition and the burning at early times was highlighted. A parameter of utmost importance called transition heat flux, was identified and depends on the composition and the structure of the cable. Below this heat flux, the decomposition is limited and concerns only the sheath. Above it, fire hazard is greatly enhanced because most often non-flame retarded insulation part contributes to heat release. The influence of spacing appears complex, and depends on the considered fire property. Copyright © 2017 Elsevier B.V. All rights reserved.
Landscape scale vegetation-type conversion and fire hazard in the San Francisco bay area open spaces
Russell, W.H.; McBride, J.R.
2003-01-01
Successional pressures resulting from fire suppression and reduced grazing have resulted in vegetation-type conversion in the open spaces surrounding the urbanized areas of the San Francisco bay area. Coverage of various vegetation types were sampled on seven sites using a chronosequence of remote images in order to measure change over time. Results suggest a significant conversion of grassland to shrubland dominated by Baccharis pilularison five of the seven sites sampled. An increase in Pseudotsuga menziesii coverage was also measured on the sites where it was present. Increases fuel and fire hazard were determined through field sampling and use of the FARSITE fire area simulator. A significant increase in biomass resulting from succession of grass-dominated to shrub-dominated communities was evident. In addition, results from the FARSITE simulations indicated significantly higher fire-line intensity, and flame length associated with shrublands over all other vegetation types sampled. These results indicate that the replacement of grass dominated with shrub-dominated landscapes has increased the probability of high intensity fires. ?? 2003 Elsevier Science B.V. All rights reserved.
Behavior of Steel-Sheathed Shear Walls Subjected to Seismic and Fire Loads.
Hoehler, Matthew S; Smith, Christopher M; Hutchinson, Tara C; Wang, Xiang; Meacham, Brian J; Kamath, Praveen
2017-07-01
A series of tests was conducted on six 2.7 m × 3.7 m shear wall specimens consisting of cold-formed steel framing sheathed on one side with sheet steel adhered to gypsum board and on the opposite side with plain gypsum board. The specimens were subjected to various sequences of simulated seismic shear deformation and fire exposure to study the influence of multi-hazard interactions on the lateral load resistance of the walls. The test program was designed to complement a parallel effort at the University of California, San Diego to investigate a six-story building subjected to earthquakes and fires. The test results reported here indicate that the fire exposure caused a shift in the failure mode of the walls from local buckling of the sheet steel in cases without fire exposure, to global buckling of the sheet steel with an accompanying 35 % reduction in lateral load capacity after the wall had been exposed to fire. This behavior appears to be predictable, which is encouraging from the standpoint of residual lateral load capacity under these severe multi-hazard actions.
Assessing Natural Hazard Vulnerability Through Marmara Region Using GIS
NASA Astrophysics Data System (ADS)
Sabuncu, A.; Garagon Dogru, A.; Ozener, H.
2013-12-01
Natural hazards are natural phenomenon occured in the Earth's system that include geological and meteorological events such as earthquakes, floods, landslides, droughts, fires and tsunamis. The metropolitan cities are vulnerable to natural hazards due to their population densities, industrial facilities and proporties. The urban layout of the megacities are complex since industrial facilities are interference with residential area. The Marmara region is placed in North-western Turkey suffered from natural hazards (earthquakes, floods etc.) for years. After 1999 Kocaeli and Duzce earthquakes and 2009 Istanbul flash floods, dramatic number of casualities and economic losses were reported by the authorities. Geographic information systems (GIS) have substantial capacity in order to develop natural disaster management. As these systems provide more efficient and reliable analysis and evaluation of the data in the management, and also convenient and better solutions for the decision making before during and after the natural hazards. The Earth science data and socio-economic data can be integrated into a GIS as different layers. Additionally, satellite data are used to understand the changes pre and post the natural hazards. GIS is a powerful software for the combination of different type of digital data. A natural hazard database for the Marmara region provides all different types of digital data to the users. All proper data collection processing and analysing are critical to evaluate and identify hazards. The natural hazard database allows users to monitor, analyze and query past and recent disasters in the Marmara Region. The long term aim of this study is to develop geodatabase and identify the natural hazard vulnerabilities of the metropolitan cities.
Fire safety: A case study of technology transfer
NASA Technical Reports Server (NTRS)
Heins, C. F.
1975-01-01
Two basic ways in which NASA-generated technology is being used by the fire safety community are described. First, improved products and systems that embody NASA technical advances are entering the marketplace. Second, NASA test data and technical information related to fire safety are being used by persons concerned with reducing the hazards of fire through improved design information and standards. The development of commercial fire safety products and systems typically requires adaptation and integration of aerospace technologies that may not have been originated for NASA fire safety applications.
LA-UR-14-27684, Analysis of Wildland Fire Hazard to the TWF at Los Alamos National Labs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gilbertson, Sarah
Wildfires represent an Anticipated Natural Phenomena Hazard for LANL and the surrounding area. The TWF facility is located in a cleared area and is surrounded on three sides by roadway pavement. Therefore, direct propagation of flames to the facility is not considered the most credible means of ignition. Rather, fires started by airborne transport of burning brands constitute the most significant wildland fire threat to the TWF. The purpose of this document is to update LA-UR-13-24529, Airborne Projection of Burning Embers – Planning and Controls for Los Alamos National Laboratory Facilities, to be specific to the TWF site and operations.
Assessing the Fire Risk for a Historic Hangar
NASA Technical Reports Server (NTRS)
Datta, Koushik; Morrison, Richard S.
2010-01-01
NASA Ames Research Center (ARC) is evaluating options of reuse of its historic Hangar 1. As a part of this evaluation, a qualitative fire risk assessment study was performed to evaluate the potential threat of combustion of the historic hangar. The study focused on the fire risk trade-off of either installing or not installing a Special Hazard Fire Suppression System in the Hangar 1 deck areas. The assessment methodology was useful in discussing the important issues among various groups within the Center. Once the methodology was deemed acceptable, the results were assessed. The results showed that the risk remained in the same risk category, whether Hangar 1 does or does not have a Special Hazard Fire Suppression System. Note that the methodology assessed the risk to Hangar 1 and not the risk to an aircraft in the hangar. If one had a high value aircraft, the aircraft risk analysis could potentially show a different result. The assessed risk results were then communicated to management and other stakeholders.
The homeowner view of thinning methods for fire hazard reduction: more positive than many think
Sarah McCaffrey
2008-01-01
With the focus of the National Fire Plan on decreasing fire risk in the wildland-urban interface, fire managers are increasingly tasked with reducing the fuel load in areas where mixed public and private ownership and a growing number of homes can make most fuel reduction methods problematic at best. In many of these intermix areas, use of prescribed burning will be...
Bibliography on aircraft fire hazards and safety. Volume 2: Safety. Part 1: Key numbers 1 to 524
NASA Technical Reports Server (NTRS)
Pelouch, J. J., Jr. (Compiler); Hacker, P. T. (Compiler)
1974-01-01
Bibliographic citations are presented to describe and define aircraft safety methods, equipment, and criteria. Some of the subjects discussed are: (1) fire and explosion suppression using whiffle balls, (2) ultraviolet flame detecting sensors, (3) evaluation of flame arrestor materials for aircraft fuel systems, (4) crash fire prevention system for supersonic commercial aircraft, and (5) fire suppression for aerospace vehicles.
Hydrological modelling for flood forecasting: Calibrating the post-fire initial conditions
NASA Astrophysics Data System (ADS)
Papathanasiou, C.; Makropoulos, C.; Mimikou, M.
2015-10-01
Floods and forest fires are two of the most devastating natural hazards with severe socioeconomic, environmental as well as aesthetic impacts on the affected areas. Traditionally, these hazards are examined from different perspectives and are thus investigated through different, independent systems, overlooking the fact that they are tightly interrelated phenomena. In fact, the same flood event is more severe, i.e. associated with increased runoff discharge and peak flow and decreased time to peak, if it occurs over a burnt area than that occurring over a land not affected by fire. Mediterranean periurban areas, where forests covered with flammable vegetation coexist with agricultural land and urban zones, are typical areas particularly prone to the combined impact of floods and forest fires. Hence, the accurate assessment and effective management of post-fire flood risk becomes an issue of priority. The research presented in this paper aims to develop a robust methodological framework, using state of art tools and modern technologies to support the estimation of the change in time of five representative hydrological parameters for post-fire conditions. The proposed methodology considers both longer- and short-term initial conditions in order to assess the dynamic evolution of the selected parameters. The research focuses on typical Mediterranean periurban areas that are subjected to both hazards and concludes with a set of equations that associate post-fire and pre-fire conditions for five Fire Severity (FS) classes and three soil moisture states. The methodology has been tested for several flood events on the Rafina catchment, a periurban catchment in Eastern Attica (Greece). In order to validate the methodology, simulated hydrographs were produced and compared against available observed data. Results indicate a close convergence of observed and simulated flows. The proposed methodology is particularly flexible and thus easily adaptable to catchments with similar hydrometeorological and geomorphological features.
Efficacy of mechanical fuel treatments for reducing wildfire hazard
Robert J. Jr. Huggett; Karen L. Abt; Wayne Shepperd
2008-01-01
Mechanical fuel treatments are increasingly being used for wildfire hazard reduction in the western U.S. However, the efficacy of these treatments for reducing wildfire hazard at a landscape scale is difficult to quantify, especially when including growth following treatment. A set of uneven- and even-aged treatments designed to reduce fire hazard were simulated on 0.8...
40 CFR 267.51 - What is the purpose of the contingency plan and how do I use it?
Code of Federal Regulations, 2014 CFR
2014-07-01
... AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE... facility. You must design the plan to minimize hazards to human health or the environment from fires, explosions, or any unplanned sudden or non-sudden release of hazardous waste or hazardous waste constituents...
40 CFR 267.51 - What is the purpose of the contingency plan and how do I use it?
Code of Federal Regulations, 2011 CFR
2011-07-01
... AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE... facility. You must design the plan to minimize hazards to human health or the environment from fires, explosions, or any unplanned sudden or non-sudden release of hazardous waste or hazardous waste constituents...
40 CFR 267.51 - What is the purpose of the contingency plan and how do I use it?
Code of Federal Regulations, 2013 CFR
2013-07-01
... AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE... facility. You must design the plan to minimize hazards to human health or the environment from fires, explosions, or any unplanned sudden or non-sudden release of hazardous waste or hazardous waste constituents...
40 CFR 267.51 - What is the purpose of the contingency plan and how do I use it?
Code of Federal Regulations, 2012 CFR
2012-07-01
... AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE... facility. You must design the plan to minimize hazards to human health or the environment from fires, explosions, or any unplanned sudden or non-sudden release of hazardous waste or hazardous waste constituents...
40 CFR 63.1217 - What are the standards for liquid fuel boilers that burn hazardous waste?
Code of Federal Regulations, 2014 CFR
2014-07-01
... boilers that burn hazardous waste? 63.1217 Section 63.1217 Protection of Environment ENVIRONMENTAL... boilers that burn hazardous waste? (a) Emission limits for existing sources. You must not discharge or... provided for in paragraph (a)(2)(iii) of this section: (i) When you burn hazardous waste with an as-fired...
40 CFR 63.1217 - What are the standards for liquid fuel boilers that burn hazardous waste?
Code of Federal Regulations, 2013 CFR
2013-07-01
... boilers that burn hazardous waste? 63.1217 Section 63.1217 Protection of Environment ENVIRONMENTAL... boilers that burn hazardous waste? (a) Emission limits for existing sources. You must not discharge or... provided for in paragraph (a)(2)(iii) of this section: (i) When you burn hazardous waste with an as-fired...
40 CFR 63.1217 - What are the standards for liquid fuel boilers that burn hazardous waste?
Code of Federal Regulations, 2012 CFR
2012-07-01
... boilers that burn hazardous waste? 63.1217 Section 63.1217 Protection of Environment ENVIRONMENTAL... that burn hazardous waste? (a) Emission limits for existing sources. You must not discharge or cause... paragraph (a)(2)(iii) of this section: (i) When you burn hazardous waste with an as-fired heating value less...
Hower, James C.; Henke, Kevin R.; O'Keefe, Jennifer M.K.; Engle, Mark A.; Blake, Donald R.; Stracher, Glenn B.
2009-01-01
Variation in gas temperatures, nearly 300 °C during the January visit to the fire versus < 50 °C in May, demonstrates the large temporal variability in fire intensity at the Tiptop mine. These preliminary results suggest that emissions from coal fires may be important, but additional data are required that address the reasons for significant variations in the composition, flow, and temperature of vent gases.
Alexander Maranghides; William Mell
2012-01-01
Destruction of homes and businesses from Wildland Urban Interface (WUI) fires have been steadily escalating as have the fire suppression costs associated with them. Since 2000, in the U.S. over 3,000 homes per year are lost to WUI fires, compared to about 900 homes in the 1990s, and 400 homes in the 1970s. In 2011, in Texas alone, over 2,000 homes were...
DefenseLink Feature: Military Helps Fight California Wildfires
planes dropping fire retardant on wildfires in southern California face hazards and challenges unique to ' * Sailors Help Victims in Need * Bush Pledges Military Will Continue to Provide Fire Aid | Video
Made It in the Timber: A Historic Overview of the Fort Leonard Wood Region, 1800-1940
1993-01-01
the brush, improve hunting, and reduce fire hazards (Malouf 1991: 26-27). For the first settlers like Turpin, the3 decrease in the frequency of fires...of these lofty heights, or descending with cautious tread3 in to the intervening gulfs- an exercise which we found equally hazardous and fatiguing...varied landscape, settlers found abundant wildlife which provided them with meat and furs. "The native fauna constituted one of the principal
Facilities Maintenance in the U.S. Navy
1986-01-01
Row’a9IVI s..Nl,I I~de 14. 11111116104 It. safeI MeAI. 5,124 AN (:lgnd) JOHN SMITH I765 IIf Figure 111-1 Work Request is EMIROENCY/SERVICE WORK...Eliminate fire, health and active life of less than 3 years safety hazards o Infrequently or only partially o Patch and reinforce instead used of...safety or health hazards and to permit reactivation within the period prescribed under mobili- zation plans o Surplus facilities a Fliminate fire, safety
NASA Astrophysics Data System (ADS)
Popov, Valeriy; Filatov, Yuriy; Lee, Hee; Golik, Anatoliy
2017-11-01
The paper discusses the problem of the underground mining safety control. The long-term air intake to coal accumulations is reviewed as one of the reasons of endogenous fires during mining. The methods of combating air leaks (inflows) in order to prevent endogenous fires are analyzed. The calculations showing the discrepancy between the design calculations for the mine ventilation, disregarding a number of mining-andgeological and mining-engineering factors, and the actual conditions of mining are given. It is proved that the conversion of operating mines to combined (pressure and exhaust) ventilation system in order to reduce the endogenous fire hazard of underground mining is unreasonable due to impossibility of providing an optimal distribution of aerodynamic pressure in mines. The conversion does not exclude the entry of air into potentially hazardous zones of endogenous fires. The essence of the combined application of positive and negative control methods for the distribution of air pressure is revealed. It consists of air doors installation in easily ventilated airways and installation of pressure equalization chambers equipped with auxiliary fans near the stoppings, working sections and in parallel airways.The effectiveness of the combined application of negative and positive control methods for the air pressure distribution in order to reduce endogenous fire hazard of mining operations is proved.
Non-supervised method for early forest fire detection and rapid mapping
NASA Astrophysics Data System (ADS)
Artés, Tomás; Boca, Roberto; Liberta, Giorgio; San-Miguel, Jesús
2017-09-01
Natural hazards are a challenge for the society. Scientific community efforts have been severely increased assessing tasks about prevention and damage mitigation. The most important points to minimize natural hazard damages are monitoring and prevention. This work focuses particularly on forest fires. This phenomenon depends on small-scale factors and fire behavior is strongly related to the local weather. Forest fire spread forecast is a complex task because of the scale of the phenomena, the input data uncertainty and time constraints in forest fire monitoring. Forest fire simulators have been improved, including some calibration techniques avoiding data uncertainty and taking into account complex factors as the atmosphere. Such techniques increase dramatically the computational cost in a context where the available time to provide a forecast is a hard constraint. Furthermore, an early mapping of the fire becomes crucial to assess it. In this work, a non-supervised method for forest fire early detection and mapping is proposed. As main sources, the method uses daily thermal anomalies from MODIS and VIIRS combined with land cover map to identify and monitor forest fires with very few resources. This method relies on a clustering technique (DBSCAN algorithm) and on filtering thermal anomalies to detect the forest fires. In addition, a concave hull (alpha shape algorithm) is applied to obtain rapid mapping of the fire area (very coarse accuracy mapping). Therefore, the method leads to a potential use for high-resolution forest fire rapid mapping based on satellite imagery using the extent of each early fire detection. It shows the way to an automatic rapid mapping of the fire at high resolution processing as few data as possible.
Communicating about smoke from wildland fire: challenges and ways to address them
Christine S. Olsen; Danielle K. Mazzotta; Eric Toman; A. Paige Fischer
2014-01-01
Wildland fire and associated management efforts are dominant topics in natural resource fields. Smoke from fires can be a nuisance and pose serious health risks and aggravate pre-existing health conditions. When it results in reduced visibility near roadways, smoke can also pose hazardous driving conditions and reduce the scenic value of vistas. Communicating about...
Modeling and risk assessment for soil temperatures beneath prescribed forest fires
Haiganoush K. Preisler; Sally M. Haase; Stephen S. Sackett
2000-01-01
Prescribed fire is a management tool used by wildland resource management organizations in many ecosystems to reduce hazardous fuels and to achieve a host of other objectives. To study the effects of fire in naturally accumulating fuel conditions, the ambient soil temperature is monitored beneath prescribed burns. In this study we developed a stochastic model for...
Hands-on learning: Its effectiveness in teaching the public about wildland fire
Tamara M. Parkinson; Jo Ellen Force; Jane Kapler Smith
2003-01-01
This study evaluated workshops for the adult public featuring experiential learning about wildland fire. Participants used hands-on activities to investigate fire behavior and ecology and to assess hazards in the wildland-urban interface. Effectiveness was examined using a pretest, a posttest following the program, and another posttest 30 days later. Participantsâ...
Using stand-level optimization to reduce crown fire hazard
David H. Graetz; John Sessions; Steven L. Garman
2007-01-01
This study evaluated the ability to generate prescriptions for a wide variety of stands when the goal is to reduce crown fire potential. Forest managers charged with reducing crown fire potential while providing for commodity and ecological production have been hampered by the complexity of possible management options. A program called Stand-Level Optimization with...
The scientific foundation of the LANDFIRE Prototype Project [Chapter 3
Robert E. Keane; Matthew Rollins
2006-01-01
The Landscape Fire and Resource Management Planning Tools Prototype Project, or LANDFIRE Prototype Project, originated from a recent mapping project that developed a set of coarse-scale spatial data layers for wildland fire management describing fire hazard and ecological status for the conterminous United States (Hardy and others 2001; Schmidt and others 2002; www. fs...
Reducing hazardous fuels on nonindustrial private forests: factors influencing landowner decisions
A. Paige Fischer
2011-01-01
In mixed-ownership landscapes, fuels conditions on private lands have implications for fire risk on public lands and vice versa. The success of efforts to mitigate fire risk depends on the extent, efficacy, and coordination of treatments on nearby ownerships. Understanding factors in forest owners' decisions to address the risk of wildland fire is therefore...
Crucial factors influencing public acceptance of fuels treatments
Sarah McCaffrey
2009-01-01
An important component of the wildland fire problem in the United States is the growing number of people living in high fire hazard areas. How people in these areas contribute to fire risk--or potentially decrease it--will be shaped by their attitudes and beliefs toward different fuel treatment approaches. Understanding the issues and concerns that influence public...
Safety. Fire Service Certification Series. Unit FSCS-FF-2-80.
ERIC Educational Resources Information Center
Pribyl, Paul F.
This training unit on safety is part of a 17-unit course package written to aid instructors in the development, teaching, and evaluation of fire fighters in the Wisconsin Fire Service Certification Series. The purpose stated for the 4-hour unit is to assist firefighters in understanding the hazards of their profession and some methods of reducing…
Basic principles of forest fuel reduction treatments
James K. Agee; Carl N. Skinner
2005-01-01
Successful fire exclusion in the 20th century has created severe fire problems across the West. Not every forest is at risk of uncharacteristically severe wildfire, but drier forests are in need of active management to mitigate fire hazard. We summarize a set of simple principles important to address in fuel reduction treatments: reduction of surface fuels, increasing...
Developing a multiscale fire treatment strategy for species habitat management
Steven P. Norman; Danny C. Lee; David A. Tallmon
2008-01-01
Reintroducing fire to manage vegetation and fuel may have poorly understood consequences for wildlife. Prescribed burning can reduce down wood and snags that provide critical habitat and mechanical thinning designed to reduce fire hazards may alter forest structures that are preferred by some species. Moreover, fine scale fuel treatments may alter wildlife and habitat...
Forest structure and fire hazard in dry forests of the Western United States
David L. Peterson; Morris C. Johnson; James K. Agee; Theresa B. Jain; Donald McKenzie; Elizabeth D. Reinhardt
2005-01-01
Fire, in conjunction with landforms and climate, shapes the structure and function of forests throughout the Western United States, where millions of acres of forest lands contain accumulations of flammable fuel that are much higher than historical conditions owing to various forms of fire exclusion. The Healthy Forests Restoration Act mandates that public land...
Development and mapping of fuel characteristics and associated fire potentials for South America
M. Lucrecia Pettinari; Roger D. Ottmar; Susan J. Prichard; Anne G. Andreu; Emilio Chuvieco
2014-01-01
The characteristics and spatial distribution of fuels are critical for assessing fire hazard, fuel consumption, greenhouse gas emissions and other fire effects. However, fuel maps are difficult to generate and update, because many regions of the world lack fuel descriptions or adequate mapped vegetation attributes to assign these fuelbeds spatially across the landscape...
EPA Response to Fruitland Magnesium Fire, Maywood, CA
The U.S. Environmental Protection Agency and its state and local partners continue the response operations and assessment of hazardous waste in the aftermath of the Fruitland Magnesium Fire Incident in Maywood, Los Angeles County, Calif.
Workplace fire-not a misfortune, but an avoidable occupational hazard in Korea.
Park, Ji-Eun; Kim, Myoung-Hee
2015-02-01
In this article, we argue that workplace fire should be understood within an occupational safety and health context. We selected two cases of fire and explosion with the greatest numbers of fatalities from the annual lists of the "Worst Manslaughter Companies of the Year" in Korea. Through review of information from major media, government, courts, and workers' advocacy organizations, we found that these incidents resulted from violations of basic safety rules by the companies, and that the penalties imposed on them were light. In addition, precarious workers were more vulnerable to such risk, and self-regulation did not work even in large corporations. Like other types of occupational hazards, explosions and fires can be prevented, but prevention requires that occupational safety and health regulations be thoroughly enforced and that heavy penalties be imposed in order to eliminate any incentives for regulatory violations. © 2015 SAGE Publications.
40 CFR 267.31 - What are the general design and operation standards?
Code of Federal Regulations, 2014 CFR
2014-07-01
... possibility of a fire, explosion, or any unplanned sudden or non-sudden release of hazardous waste or hazardous waste constituents to air, soil, or surface water that could threaten human health or the... (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE FACILITIES...
40 CFR 267.31 - What are the general design and operation standards?
Code of Federal Regulations, 2012 CFR
2012-07-01
... possibility of a fire, explosion, or any unplanned sudden or non-sudden release of hazardous waste or hazardous waste constituents to air, soil, or surface water that could threaten human health or the... (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE FACILITIES...
40 CFR 267.31 - What are the general design and operation standards?
Code of Federal Regulations, 2013 CFR
2013-07-01
... possibility of a fire, explosion, or any unplanned sudden or non-sudden release of hazardous waste or hazardous waste constituents to air, soil, or surface water that could threaten human health or the... (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE FACILITIES...
40 CFR 267.31 - What are the general design and operation standards?
Code of Federal Regulations, 2011 CFR
2011-07-01
... possibility of a fire, explosion, or any unplanned sudden or non-sudden release of hazardous waste or hazardous waste constituents to air, soil, or surface water that could threaten human health or the... (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE FACILITIES...
40 CFR 267.54 - When must I amend the contingency plan?
Code of Federal Regulations, 2010 CFR
2010-07-01
... WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE FACILITIES OPERATING UNDER A... for fires, explosions, or releases of hazardous waste or hazardous waste constituents, or changes the response necessary in an emergency. (d) You change the list of emergency coordinators. (e) You change the...
40 CFR 267.54 - When must I amend the contingency plan?
Code of Federal Regulations, 2011 CFR
2011-07-01
... WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE FACILITIES OPERATING UNDER A... for fires, explosions, or releases of hazardous waste or hazardous waste constituents, or changes the response necessary in an emergency. (d) You change the list of emergency coordinators. (e) You change the...
Lessons learnt from a factory fire with asbestos-containing fallout.
Bridgman, S A
1999-06-01
Fallout containing asbestos from a factory fire at Tranmere, Wirral, England, landed on a highly populated urban area with an estimated 16000 people living in the area worst affected, which included a shipbuilding community. There was considerable public concern over the health impact of the acute environmental incident, and great media interest. A descriptive study was carried out of the acute environmental incident and its management, and the difficulties encountered. Practical lessons learnt include need for: increased fire-fighter awareness of potential adverse health effects from asbestos in the structure of buildings; early involvement of both Local Authority environmental health and National Health Service public health departments; creation of a systematic local database of potential environmental health hazards in the structure of buildings as well as their contents; 24 hour on-call arrangements with laboratories expert in analyses of fire fallout; rapid quantitative analyses of multiple environmental samples; district written policy on handling asbestos incidents; systematic assessment of fright and media factors in public impact of an incident; dedicated public help-lines open long hours; consistent evidence-based public messages from all those communicating with the public; measurement of asbestos levels in the street and homes for public reassurance; local and health authorities' subscription to an environmental incident support service; formation of an acute environmental incident team to jointly manage and publicly report on airborne acute environmental incidents; clear government definition of responsibilities of different agencies. This paper provides a description of important lessons learnt during an acute environmental incident with asbestos-containing fallout. It will be helpful to those involved in the practical planning for and management of future incidents.
Fire monitoring capability of the joint Landsat and Sentinel 2 constellation
NASA Astrophysics Data System (ADS)
Murphy, S.; Wright, R.
2017-12-01
Fires are a global hazard. Landsat and Sentinel 2 can monitor the Earth's surface every 2 - 4 days. This provides an important opportunity to complement the operational (lower resolution) fire monitoring systems. Landsat-class sensors can detect small fires that would be missed by MODIS-classed sensors. All large fires start out as small fires. We analyze fire patterns in California from 1984 to 2017 and compare the performance of Landsat-type and MODIS-type sensors. Had an operational Landsat-Sentinel 2 fire detection system been in place at the time of the Soberanes fire last year (i.e. August 2016), the cost of suppressing of this fire event (US $236 million) could potentially have been reduced by an order of magnitude.
A New Fire Hazard for MR Imaging Systems: Blankets-Case Report.
Bertrand, Anne; Brunel, Sandrine; Habert, Marie-Odile; Soret, Marine; Jaffre, Simone; Capeau, Nicolas; Bourseul, Laetitia; Dufour-Claude, Isabelle; Kas, Aurélie; Dormont, Didier
2018-02-01
In this report, a case of fire in a positron emission tomography (PET)/magnetic resonance (MR) imaging system due to blanket combustion is discussed. Manufacturing companies routinely use copper fibers for blanket fabrication, and these fibers may remain within the blanket hem. By folding a blanket with these copper fibers within an MR imaging system, one can create an electrical current loop with a major risk of local excessive heating, burn injury, and fire. This hazard applies to all MR imaging systems. Hybrid PET/MR imaging systems may be particularly vulnerable to this situation, because blankets are commonly used for fluorodeoxyglucose PET to maintain a normal body temperature and to avoid fluorodeoxyglucose uptake in brown adipose tissue. © RSNA, 2017.
Predicting Geomorphic and Hydrologic Risks after Wildfire Using Harmonic and Stochastic Analyses
NASA Astrophysics Data System (ADS)
Mikesell, J.; Kinoshita, A. M.; Florsheim, J. L.; Chin, A.; Nourbakhshbeidokhti, S.
2017-12-01
Wildfire is a landscape-scale disturbance that often alters hydrological processes and sediment flux during subsequent storms. Vegetation loss from wildfires induce changes to sediment supply such as channel erosion and sedimentation and streamflow magnitude or flooding. These changes enhance downstream hazards, threatening human populations and physical aquatic habitat over various time scales. Using Williams Canyon, a basin burned by the Waldo Canyon Fire (2012) as a case study, we utilize deterministic and statistical modeling methods (Fourier series and first order Markov chain) to assess pre- and post-fire geomorphic and hydrologic characteristics, including of precipitation, enhanced vegetation index (EVI, a satellite-based proxy of vegetation biomass), streamflow, and sediment flux. Local precipitation, terrestrial Light Detection and Ranging (LiDAR) scanning, and satellite-based products are used for these time series analyses. We present a framework to assess variability of periodic and nonperiodic climatic and multivariate trends to inform development of a post-wildfire risk assessment methodology. To establish the extent to which a wildfire affects hydrologic and geomorphic patterns, a Fourier series was used to fit pre- and post-fire geomorphic and hydrologic characteristics to yearly temporal cycles and subcycles of 6, 4, 3, and 2.4 months. These cycles were analyzed using least-squares estimates of the harmonic coefficients or amplitudes of each sub-cycle's contribution to fit the overall behavior of a Fourier series. The stochastic variances of these characteristics were analyzed by composing first-order Markov models and probabilistic analysis through direct likelihood estimates. Preliminary results highlight an increased dependence of monthly post-fire hydrologic characteristics on 12 and 6-month temporal cycles. This statistical and probabilistic analysis provides a basis to determine the impact of wildfires on the temporal dependence of geomorphic and hydrologic characteristics, which can be incorporated into post-fire mitigation, management, and recovery-based measures to protect and rehabilitate areas subject to influence from wildfires.
30 CFR 56.4101 - Warning signs.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and Control... open flames shall be posted where a fire or explosion hazard exists. ...
30 CFR 57.4101 - Warning signs.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control... open flames shall be posted where a fire or explosion hazard exists. ...
Prevention and Control of Highway Tunnel Fires
DOT National Transportation Integrated Search
1984-05-01
This study investigates steps that can be taken to reduce the risk, damage, and : fatalities from fires in existing and future highway tunnels and the effect of : unrestricted transit of hazardous materials through them. The history of : highway tunn...
Elevated temperature properties of weathering steel.
DOT National Transportation Integrated Search
2014-01-01
In recent decades, bridge fires have become a major concern in the U.S. Fire hazard in bridges can result in significant economic and public losses. New construction of bridges often use Weathering Steel (also known as Corten Steel), whic...
29 CFR 1915.501 - General provisions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... safety plan including hazards, controls, fire safety and health rules, and emergency procedures; (ii... Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard...
29 CFR 1915.501 - General provisions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... safety plan including hazards, controls, fire safety and health rules, and emergency procedures; (ii... Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard...
49 CFR 193.2611 - Fire protection.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 3 2010-10-01 2010-10-01 false Fire protection. 193.2611 Section 193.2611 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY LIQUEFIED NATURAL GAS FACILITIES...
NASA Astrophysics Data System (ADS)
Jiang, W.; Wang, F.; Meng, Q.; Li, Z.; Liu, B.; Zheng, X.
2018-04-01
This paper presents a new standardized data format named Fire Markup Language (FireML), extended by the Geography Markup Language (GML) of OGC, to elaborate upon the fire hazard model. The proposed FireML is able to standardize the input and output documents of a fire model for effectively communicating with different disaster management systems to ensure a good interoperability. To demonstrate the usage of FireML and testify its feasibility, an adopted forest fire spread model being compatible with FireML is described. And a 3DGIS disaster management system is developed to simulate the dynamic procedure of forest fire spread with the defined FireML documents. The proposed approach will enlighten ones who work on other disaster models' standardization work.
Post Fire Vegetation Recovery in Greece after the large Drought event of 2007
NASA Astrophysics Data System (ADS)
Gouveia, Célia M.; Bastos, Ana; DaCamara, Carlos; Trigo, Ricardo
2013-04-01
Fire is a natural factor of Mediterranean ecosystems. However, fire regimes in the European Mediterranean areas have been changing in the last decades, mainly due to land-use changes and climate driven factors possibly associated with climatic warming (e.g. decline of precipitation, increasing temperatures but also higher frequency of heatwaves). In Greece, the fire season of 2007 was particularly devastating, achieving the new all-time record of estimated burnt area (225 734 ha), since 1980. Additionally, we must stress that prior to the summer fire season in 2007, Greece suffered an exceptional drought event. This severe drought had a strong negative impact in vegetation dynamics. Since water availability is a crucial factor in post-fire vegetation recovery, it is desirable to assess the impact that such water-stress conditions had on fire sensitivity and post-fire vegetation recovery. Based on monthly values of NDVI, at the 1km×1km spatial scale, as obtained from the VEGETATION-SPOT5 instrument, from 1999 to 2010, large burnt scars are identified in Greece, during 2007 fire season. Vegetation recovery is then assessed based on a mono parametric regression model originally developed by Gouveia et al. (2010) to identify large burnt scars in Portugal during the 2003 fire season and after applied to 2005 fire season (Bastos et al., 2012). Some large burnt areas are selected and the respective NDVI behaviour is monitored throughout the pre and the post fire period. The vegetation dynamics during the pre-fire period is analysed and related to the extreme climatic events that characterised the considered period. An analysis is made of the dependence of recovery rates on land cover types and fire damage. Finally results are compared to results already obtained for Portugal (Gouveia et al. 2010). This work emphasises the use of a simple methodology, when applied to low resolution satellite imagery in order to monitor vegetation recovery after large fires events over distinct regions of Mediterranean Europe. Gouveia C., DaCamara C.C, Trigo R.M. (2010). "Post-fire vegetation dynamics in Portugal". Natural Hazards and Earth System Sciences, 10, 4, 673-684. Bastos A., Gouveia C., DaCamara C.C., and Trigo R.M.: Modelling post-fire vegetation recovery in Portugal.Biogeosciences, 8, 4559-4601, 2011.
... and direct flame PROTECTION: overshoes or boots of fire-resistant materials with wooden soles HAZARD: high voltage PROTECTION: shoes with rubber or cork heels and soles, and no exposed metal parts HAZARD: hot surfaces PROTECTION: safety shoes with ...
Kevin C. Ryan; Eric Rigolot; Francisco C. Rego; Herminio Botelho; Jose A. Vega; Paulo M. Fernandes; Tatiana M. Sofronova
2010-01-01
Globally prescribed burning is widely used for agro-forestry, restoration, and conservation to modify species composition and stand structure. Commonly stated goals of prescribed burns include to reduce hazardous fuels, improve speciesâ habitat, reduce the potential for severe fires in the wildland urban interface or protect municipal watersheds. Treatments may focus...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-13
... hazardous substances (EHSs) and to provide the public, local agencies, fire departments, and other emergency... submitted to the SERC, LEPC and the local fire department. The implementing regulations for sections 311 and... burden for SERCs, LEPCs and fire departments in the form of draft guidance in the preamble to the June 8...
Timothy Ingalsbee; Daniel Henry; Oshana Catranides; Todd Schulke
2008-01-01
Successfully educating homeowners and communities about wildland fire ecology and management, reducing hazardous fuels, and restoring fire-adapted forest ecosystems will place enormous demands on the budgets, resources, and staff of federal agencies for several decades to come. This work can be aided by collaboration with non-governmental organizations (NGOs) that are...
Federal Aviation Administration Plan for Research, Engineering & Development, 1998.
1998-02-01
release rate. • Improved fracture toughness of non-combustible geopolymer composite fire barriers to enable use as interior and secondary composites ...Fire Resistant, Non-Toxic Interior Panels for Evaluation of Heat Release Rate ♦ Improved Fracture Toughness of Non-Combustible Geopolymer Composite ... composites , atmospheric hazards, crash worthiness, fire safety, and forensics capabilities to support accident investigations. Aviation Security R,E&D
NASA Astrophysics Data System (ADS)
Falakh, Fajrul; Setiani, Onny
2018-02-01
Water Treatment Plant (WTP) is an important infrastructure to ensure human health and the environment. In its development, aspects of environmental safety and health are of concern. This paper case study was conducted at the Water Treatment Plant Company in Semarang, Central Java, Indonesia. Hazard identification and risk assessment is one part of the occupational safety and health program at the risk management stage. The purpose of this study was to identify potential hazards using hazard identification methods and risk assessment methods. Risk assessment is done using criteria of severity and probability of accident. The results obtained from this risk assessment are 22 potential hazards present in the water purification process. Extreme categories that exist in the risk assessment are leakage of chlorine and industrial fires. Chlorine and fire leakage gets the highest value because its impact threatens many things, such as industrial disasters that could endanger human life and the environment. Control measures undertaken to avoid potential hazards are to apply the use of personal protective equipment, but management will also be better managed in accordance with hazard control hazards, occupational safety and health programs such as issuing work permits, emergency response training is required, Very useful in overcoming potential hazards that have been determined.
Noise exposure assessment and abatement strategies at an indoor firing range.
Kardous, Chucri A; Willson, Robert D; Hayden, Charles S; Szlapa, Piotr; Murphy, William J; Reeves, Efrem R
2003-08-01
Exposure to hazardous impulse noise is common during the firing of weapons at indoor firing ranges. The aims of this study were to characterize the impulse noise environment at a law enforcement firing range; document the insufficiencies found at the range from a health and safety standpoint; and provide noise abatement recommendations to reduce the overall health hazard to the auditory system. Ten shooters conducted a typical live-fire exercise using three different weapons--the Beretta.40 caliber pistol, the Remington.308 caliber shotgun, and the M4.223 caliber assault rifle. Measurements were obtained at 12 different positions throughout the firing range and adjacent areas using dosimeters and sound level meters. Personal and area measurements were recorded to a digital audio tape (DAT) recorder for further spectral analysis. Peak pressure levels inside the firing range reached 163 decibels (dB) in peak pressure. Equivalent sound levels (Leq) ranged from 78 decibels, A-weighted (dBA), in office area adjacent to the range to 122 dBA inside the range. Noise reductions from wall structures ranged from 29-44 dB. Noise abatement strategies ranged from simple noise control measures (such as sealing construction joints and leaks) to elaborate design modifications to eliminate structural-borne sounds using acoustical treatments. Further studies are needed to better characterize the effects of firing weapons in enclosed spaces on hearing and health in general.
Automated Wildfire Detection Through Artificial Neural Networks
NASA Technical Reports Server (NTRS)
Miller, Jerry; Borne, Kirk; Thomas, Brian; Huang, Zhenping; Chi, Yuechen
2005-01-01
Wildfires have a profound impact upon the biosphere and our society in general. They cause loss of life, destruction of personal property and natural resources and alter the chemistry of the atmosphere. In response to the concern over the consequences of wildland fire and to support the fire management community, the National Oceanic and Atmospheric Administration (NOAA), National Environmental Satellite, Data and Information Service (NESDIS) located in Camp Springs, Maryland gradually developed an operational system to routinely monitor wildland fire by satellite observations. The Hazard Mapping System, as it is known today, allows a team of trained fire analysts to examine and integrate, on a daily basis, remote sensing data from Geostationary Operational Environmental Satellite (GOES), Advanced Very High Resolution Radiometer (AVHRR) and Moderate Resolution Imaging Spectroradiometer (MODIS) satellite sensors and generate a 24 hour fire product for the conterminous United States. Although assisted by automated fire detection algorithms, N O M has not been able to eliminate the human element from their fire detection procedures. As a consequence, the manually intensive effort has prevented NOAA from transitioning to a global fire product as urged particularly by climate modelers. NASA at Goddard Space Flight Center in Greenbelt, Maryland is helping N O M more fully automate the Hazard Mapping System by training neural networks to mimic the decision-making process of the frre analyst team as well as the automated algorithms.
Measuring wildland fire fighter performance with wearable technology.
Parker, Richard; Vitalis, Antonios; Walker, Robyn; Riley, David; Pearce, H Grant
2017-03-01
Wildland (rural) fire fighting is a physically demanding and hazardous occupation. An observational study was conducted to explore the use of new technologies for the field study of fire fighters at wildfires and to understand the work pressures of wildland fire fighting. The research was carried out with two fire fighters at real fires wearing microphones, miniature video cameras, heart rate monitors and GPS units to record their actions and location at wildfire events. The fire fighters were exposed to high physiological workloads (heart rates of up to 180 beats per minute) and walked considerable distances at the fires. Results from this study have been used in presentations to fire fighters and non-operational fire personnel to understand the pressures fire fighters are under and how others complete the fire fighting tasks. Copyright © 2016 Elsevier Ltd. All rights reserved.
29 CFR 1910.144 - Safety color code for marking physical hazards.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 29 Labor 5 2013-07-01 2013-07-01 false Safety color code for marking physical hazards. 1910.144... § 1910.144 Safety color code for marking physical hazards. (a) Color identification—(1) Red. Red shall be the basic color for the identification of: (i) Fire protection equipment and apparatus. [Reserved] (ii...
29 CFR 1910.144 - Safety color code for marking physical hazards.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 29 Labor 5 2014-07-01 2014-07-01 false Safety color code for marking physical hazards. 1910.144... § 1910.144 Safety color code for marking physical hazards. (a) Color identification—(1) Red. Red shall be the basic color for the identification of: (i) Fire protection equipment and apparatus. [Reserved] (ii...
29 CFR 1910.144 - Safety color code for marking physical hazards.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 29 Labor 5 2012-07-01 2012-07-01 false Safety color code for marking physical hazards. 1910.144... § 1910.144 Safety color code for marking physical hazards. (a) Color identification—(1) Red. Red shall be the basic color for the identification of: (i) Fire protection equipment and apparatus. [Reserved] (ii...
Forest vegetation simulation tools and forest health assessment
Richard M. Teck; Melody Steele
1995-01-01
A Stand Hazard Rating System for Central ldaho forests has been incorporated into the Central ldaho Prognosis variant of the Forest Vegetation Simulator to evaluate how insects, disease and fire hazards within the Deadwood River Drainage change over time. A custom interface, BOISE.COMPUTE.PR, has been developed so hazard ratings can be electronically downloaded...
Rocky Mountain Research Station USDA Forest Service
2004-01-01
The amount of science applicable to the management of wildfire hazards is increasing daily. In addition, the attitudes of landowners and policymakers about fire and fuels management are changing. This fact sheet discusses three critical keys to communicating about wildfire hazards.
Pursuing the Delta -- Maximizing Opportunities to Integrate Sustainability in the Funding Processes
2011-03-03
that may contain safety and health hazards. This is not an all-inclusive list: a. Fire protection issues b. Toxic fumes (i.e., engine exhaust...hazards shall be reported as part of the SAR. A.6 Hazardous Materials. The contractor shall not use cadmium, hexavalent chromium , or other
30 CFR 57.4600 - Extinguishing equipment.
Code of Federal Regulations, 2010 CFR
2010-07-01
....4600 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention... electrically conductive extinguishing agent could create an electrical hazard, a multipurpose dry-chemical fire...
30 CFR 56.4500 - Heat sources.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and Control... shall be separated from combustible materials if a fire hazard could be created. ...
30 CFR 56.4600 - Extinguishing equipment.
Code of Federal Regulations, 2010 CFR
2010-07-01
....4600 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and... conductive extinguishing agent could create an electrical hazard, a multipurpose dry-chemical fire...
30 CFR 57.4500 - Heat sources.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control... shall be separated from combustible materials if a fire hazard could be created. ...
How EPA's Asbestos Regulations Apply to Residential Buildings Used for Fire Training
Memos and guidance from the Office of Air Quality Planning and Standards that clarify how the Asbestos National Emissions Standard for Hazardous Air Pollutants applies to residential buildings used for fire training, also known as acquired structures.
NASA Technical Reports Server (NTRS)
Kuhn, Fritz
1931-01-01
The following discussion is at first restricted to the light-oil engines now in use. We shall consider how far it is possible to reduce fire hazards by changes in the design of the engines and carburetors and in the arrangement of the fuel pipes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xiong, Yongliang; Wang, Yifeng
Advanced, fire-resistant activated carbon compositions useful in adsorbing gases; and having vastly improved fire resistance are provided, and methods for synthesizing the compositions are also provided. The advanced compositions have high gas adsorption capacities and rapid adsorption kinetics (comparable to commercially-available activated carbon), without having any intrinsic fire hazard. They also have superior performance to Mordenites in both adsorption capacities and kinetics. In addition, the advanced compositions do not pose the fibrous inhalation hazard that exists with use of Mordenites. The fire-resistant compositions combine activated carbon mixed with one or more hydrated and/or carbonate-containing minerals that release H.sub.2O and/or CO.sub.2more » when heated. This effect raises the spontaneous ignition temperature to over 500.degree. C. in most examples, and over 800.degree. C. in some examples. Also provided are methods for removing and/or separating target gases, such as Krypton or Argon, from a gas stream by using such advanced activated carbons.« less
Wagner, Norbert L; Berger, Jürgen; Flesch-Janys, Dieter; Koch, Peter; Köchel, Anja; Peschke, Michel; Ossenbach, Trude
2006-01-01
Background The healthy worker effect may hide adverse health effects in hazardous jobs, especially those where physical fitness is required. Fire fighters may serve as a good example because they sometimes are severely exposed to hazardous substances while on the other hand their physical fitness and their strong health surveillance by far exceeds that of comparable persons from the general population. Methods To study this effect a historic cohort study was conducted to assess mortality and life expectancy of professional fire fighters of the City of Hamburg, Germany. Fire departments and trade unions questioned the validity of existing studies from outside Germany because of specific differences in the professional career. No mortality study had been conducted so far in Germany and only few in Europe. Information on all active and retired fire fighters was extracted from personnel records. To assure completeness of data the cohort was restricted to all fire fighters being active on January 1, 1950 or later. Follow up of the cohort ended on June 30th 2000. Vital status was assessed by personnel records, pension fund records and the German residence registries. Mortality of fire fighters was compared to mortality of the Hamburg and German male population by means of standardized mortality ratios. Life expectancy was calculated using life table analysis. Multivariate proportional hazard models were used to assess the effect of seniority, time from first employment, and other occupational characteristics on mortality. Results The cohort consists of 4640 fire fighters accumulating 111796 person years. Vital status could be determined for 98.2% of the cohort. By the end of follow up 1052 person were deceased. Standardized Mortality Ratio (SMR) for the total cohort was 0.79 (95% CI, 0.74–0.84) compared to Hamburg reference data and 0.78 (95% CI, 0.74–0.83) compared to National German reference data. Conditional life expectancy of a 30 year old fire fighter was 45.3 years as compared to 42.9 year of a German male in normal population. Job tasks, rank status and early retirement negatively influenced mortality. For fire fighters with comparably short duration of employment the mortality advantage diminished with longer time since first employment. SMR of persons who retired early was 1.25 (95% CI, 1.13–1.60) in reference to the general German population and the SMR of 1.71 (1.18–2.50) in the multivariate regression model. Conclusion A strong healthy worker effect was observed for the cohort, which diminished with longer time since first employment for fire fighters with shorter duration of employment, as expected. The negative effects on mortality of job tasks, rank status and in particular early retirement indicate the presence of undetermined and specific risks related to occupational hazards of fire fighters. PMID:17020604
16 CFR 1500.15 - Labeling of fire extinguishers.
Code of Federal Regulations, 2011 CFR
2011-01-01
... hazard “Dangerous gas formed when used to extinguish flame or on contact with heat” are required labeling...)(1), the signal word “Danger” and the statement of hazard “Poisonous gases formed when used to...
16 CFR 1500.15 - Labeling of fire extinguishers.
Code of Federal Regulations, 2014 CFR
2014-01-01
... hazard “Dangerous gas formed when used to extinguish flame or on contact with heat” are required labeling...)(1), the signal word “Danger” and the statement of hazard “Poisonous gases formed when used to...
16 CFR 1500.15 - Labeling of fire extinguishers.
Code of Federal Regulations, 2012 CFR
2012-01-01
... hazard “Dangerous gas formed when used to extinguish flame or on contact with heat” are required labeling...)(1), the signal word “Danger” and the statement of hazard “Poisonous gases formed when used to...
Stevens, M.R.; Bossong, C.R.; Rupert, M.G.; Ranalli, A.J.; Cassidy, E.W.; Druliner, A.D.
2008-01-01
Following a wildfire, such as the 2002 Missionary Ridge fire, a number of hydrologic hazards may develop that can have an important impact on water resources, businesses, homes, reservoirs, roads, and utilities in the wildland urban interface (areas where homes and commercial developments are interspersed with wildlands) in mountainous areas of the Western United States. This fact sheet describes these hazards and identifies approaches to quantify them, thus enabling land and resource managers to plan for and mitigate the effects of these hazards. The fact sheet has been produced in association with the U.S. Geological Survey (USGS) Fire Science Thrust program and the Colorado Front Range Demonstration Project (CFRDP). The current (2007) focus of the CFRDP is on the Three Lakes watershed in Grand County, Colorado, which has applicability to many similar forested, mountain areas in the Western United States.
LaWen T. Hollingsworth; Laurie L. Kurth; Bernard R. Parresol; Roger D. Ottmar; Susan J. Prichard
2012-01-01
Landscape-scale fire behavior analyses are important to inform decisions on resource management projects that meet land management objectives and protect values from adverse consequences of fire. Deterministic and probabilistic geospatial fire behavior analyses are conducted with various modeling systems including FARSITE, FlamMap, FSPro, and Large Fire Simulation...
Code of Federal Regulations, 2012 CFR
2012-07-01
... from the fire protection system in conjunction with testing or servicing, and recycled for later use or... protective equipment (e.g., respiratory protection), fire protection, hazard communication, worker training...
Code of Federal Regulations, 2013 CFR
2013-07-01
... from the fire protection system in conjunction with testing or servicing, and recycled for later use or... protective equipment (e.g., respiratory protection), fire protection, hazard communication, worker training...
Code of Federal Regulations, 2014 CFR
2014-07-01
... from the fire protection system in conjunction with testing or servicing, and recycled for later use or... protective equipment (e.g., respiratory protection), fire protection, hazard communication, worker training...
Development of a hazard-based method for evaluating the fire safety of passenger trains
DOT National Transportation Integrated Search
1999-01-01
The fire safety of U.S. passenger rail trains currently is addressed through small-scale flammability and smoke emission tests and performance criteria promulgated by the Federal Railroad Administration (FRA). The FRA approach relies heavily on test ...
30 CFR 56.4104 - Combustible waste.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and... liquids, shall not accumulate in quantities that could create a fire hazard. (b) Until disposed of...
30 CFR 56.4104 - Combustible waste.
Code of Federal Regulations, 2013 CFR
2013-07-01
... properly, waste or rags containing flammable or combustible liquids that could create a fire hazard shall... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and...
30 CFR 56.4104 - Combustible waste.
Code of Federal Regulations, 2012 CFR
2012-07-01
... properly, waste or rags containing flammable or combustible liquids that could create a fire hazard shall... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and...
30 CFR 56.4104 - Combustible waste.
Code of Federal Regulations, 2014 CFR
2014-07-01
... properly, waste or rags containing flammable or combustible liquids that could create a fire hazard shall... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and...
30 CFR 56.4104 - Combustible waste.
Code of Federal Regulations, 2011 CFR
2011-07-01
... properly, waste or rags containing flammable or combustible liquids that could create a fire hazard shall... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and...
Hazard Mapping System Fire and Smoke Product - Office of Satellite and
Floater Imagery NASA MODIS NASA MODIS Rapid Response NESDIS Products Archived Fire Products (6 months OMI SO2 NASA data portal NRL Aerosol page NRL Aerosol links NOAA Earth System Research Lab RAMSDIS G
Fire safety evaluation system for NASA office/laboratory buildings
NASA Astrophysics Data System (ADS)
Nelson, H. E.
1986-11-01
A fire safety evaluation system for office/laboratory buildings is developed. The system is a life safety grading system. The system scores building construction, hazardous areas, vertical openings, sprinklers, detectors, alarms, interior finish, smoke control, exit systems, compartmentation, and emergency preparedness.
2013-03-08
applicable fire protection standards for two of the three projects we reviewed that required a fire sprinkler system . Specifically, the Secure...RSOI and Command and Control facilities do not have fire sprinkler systems as required by Unified Facilities Criteria 3-600-01, Section 4-2.2...stated that, as such, those facilities did not need fire sprinkler systems . Based on the justification provided by the Air Force on the DD Form 1391s
Fire research publications, 1983
NASA Astrophysics Data System (ADS)
Jason, N. H.
1984-04-01
Approximately 130 articles are cited addressing topics in fire fighting and prevention, combustion physics, and fire related hazards. Only publications prepared by members of the Center for Fire Research (CFR), by other National Bureau of Standards (NBS) personnel for CFR, or by external laboratories under contract or grant from the CFR are cited. For documents that are available for purchase from either the Government Printing Office (GPO) or the National Technical Information Service (NTIS), the specific order number has been included in the citation.
Alicia L. Reiner; Nicole M. Vaillant; JoAnn Fites-Kaufman; Scott N. Dailey
2009-01-01
Due to increases in tree density and hazardous fuel loading in Sierra Nevadan forests, land management is focusing on fuel reduction treatments to moderate the risk of catastrophic fires. Fuel treatments involving mechanical and prescribed fire methods can reduce surface as well as canopy fuel loads. Mastication is a mechanical method which shreds smaller trees and...
Stacy A. Drury; Narasimhan Larkin; Tara T. Strand; ShihMing Huang; Scott J. Strenfel; Theresa E. O' Brien; Sean M. Raffuse
2014-01-01
Land managers rely on prescribed burning and naturally ignited wildfires for ecosystem management, and must balance trade-offs of air quality, carbon storage, and ecosystem health. A current challenge for land managers when using fire for ecosystem management is managing smoke production. Smoke emissions are a potential human health hazard due to the production of fine...
Understanding of urban hazards, fire, and tsunamis
Hays, Walter W.; ,
1997-01-01
Understanding of the causes and solutions of an urban area's (e.g., Los Angeles, San Diego, San Francisco, Oakland, Seattle, Portland, Anchorage, Salt Lake City, Memphis, St. Louis, Charleston, Boston, San Juan) vulnerability to earthquakes, fire, and tsunamis has increased significantly during the past 50 years, and during the current International Decade for Natural Disaster Reduction (IDNDR). Vulnerability is caused by flaws in planning, siting, design, construction, and use. It is fundamentally dependent upon the hazard, built, and policy environments of the urban area. Reduction of vulnerability is directly related to the decision-making process that calls for the adoption and enforcement of risk management programs (e.g., mitigation, preparedness, emergency response, and recovery measures) that are designed to make the urban area resilient to earthquakes, fires, and, as appropriate, tsunamis.
Remote sensing information for fire management and fire effects assessment
NASA Astrophysics Data System (ADS)
Chuvieco, Emilio; Kasischke, Eric S.
2007-03-01
Over the past decade, much research has been carried out on the utilization of advanced geospatial technologies (remote sensing and geographic information systems) in the fire science and fire management disciplines. Recent advances in these technologies were the focus of a workshop sponsored by the EARSEL special interest group (SIG) on forest fires (FF-SIG) and the Global Observation of Forest and Land Cover Dynamics (GOFC-GOLD) fire implementation team. Here we summarize the framework and the key findings of papers submitted from this meeting and presented in this special section. These papers focus on the latest advances for near real-time monitoring of active fires, prediction of fire hazards and danger, monitoring of fuel moisture, mapping of fuel types, and postfire assessment of the impacts from fires.
Simulating the effect of ignition source type on forest fire statistics
NASA Astrophysics Data System (ADS)
Krenn, Roland; Hergarten, Stefan
2010-05-01
Forest fires belong to the most frightening natural hazards, and have long-term ecological and economic effects on the regions involved. It was found that their frequency-area distributions show power-law behaviour under a wide variety of conditions, interpreting them as a self-organised critical phenomenon. Using computer simulations, self-organised critical behaviour manifests in simple cellular automaton models. With respect to ignition source, forest fires can be categorised as lightning-induced or as a result of human activity. Lightning fires are considered to be natural, whereas ``man made'' fires are frequently caused by some sort of technological disaster, such as sparks from wheels of trains, the rupture of overhead electrical lines, the misuse of electrical or mechanical devices and so on. Taking into account that such events rarely occur deep in the woods, man made fires should start preferably on the edge of a forest or where the forest is not very dense. We present a modification in the self-organised critical Drossel-Schwabl forest fire model that takes these two different triggering mechanisms into account and increases the scaling exponent of the frequency-area distribution by ca. 1/3. Combined simulations further predict a dependence of the overall event-size distribution on the ratio of lightning-induced and man made fires as well as a splitting of their partial distributions. Lightning is identified as the dominant mechanism in the regime of the largest fires. The results are confirmed by the analysis of the Canadian Large Fire Database and suggest that lightning-induced and man made forest fires cannot be treated separately in wildfire modelling, hazard assessment and forest management.
The influence of market proximity on national forest hazardous fuels treatments
Max Nielsen-Pincus; Susan Charnley; Cassandra Moseley
2013-01-01
The US Department of Agriculture Forest Serviceâs focus on hazardous fuels reduction has increased since the adoption of the National Fire Plan in 2001. However, appropriations for hazardous fuels reduction still lag behind wildfire suppression spending. Offsetting fuels treatment costs through biomass utilization or by using innovative administrative mechanisms such...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-27
... for each emission unit type (e.g., gas- or oil-fired paper machine dryers) based on the most common... 63 National Emission Standards for Hazardous Air Pollutants From the Pulp and Paper Industry...-AQ41 National Emission Standards for Hazardous Air Pollutants From the Pulp and Paper Industry AGENCY...
Preliminary results of the PREFER FP7 Project
NASA Astrophysics Data System (ADS)
Fusilli, Lorenzo; Laneve, Giovanni; De Bonis, Roberto; Sebastian, Ana; Ferrucci, Fabrizio; Oliveira, Sandra
2014-05-01
The need to improve the information and intelligence support for forest fire prevention is widely recognized. Fire prevention is still the most cost-effective strategy when compared to firefighting and extinguishing that are costly, local, and triggered only in response to already ongoing crises. PREFER project, funded under the EU FP7 (G.A. 312931), intends to contribute at responding to such a pragmatic need of southern Europe's forests by: providing timely information products based on the exploitation of all available spacecraft sensors, offering a portfolio of products focused on pre- and post-crisis forest fire emergency, suitable for the users in the different countries of the European Mediterranean area. The PREFER Service portfolio consists of two main services: 1. Information Support to Fire Preparedness/Prevention Phase" (ISP) Service 2. Information Support to Fire Recovery/Reconstruction Phase" (ISR) Service This service is already at an advanced stage having completed the first year of activity. During this time several products have been consolidated: seasonal fuel maps; daily and seasonal fire hazard maps; seasonal risk maps; prescribed fire maps. This paper aims at presenting the preliminary results of the research activity carried out in the framework of the PREFER project, focusing, in particular, on these recalled above. As for Fire Risk and Hazard assessment, many indexes have been developed in the last years. Hardly any of them uses data derived from satellite images. The FPI index is an exception to this rule which, in addition, makes use of meteorological data. In spite of being a very complete index, the FPI still allows room for improvement which justify the interest of PREFER in it. PREFER's innovative approach to FPI will allow taking into account the effect of solar illumination conditions in determining the humidity present in the dead vegetation, and therefore its proneness to burn. PREFER innovation also focus in allowing the index to take into account the influence of water present in the alive vegetation (relevant in determining the fire regime) through the Equivalent Water Thickness. PREFER will use daily FPI forecasts to produce a seasonal fire hazard index by introducing in the model the human factor as captured by the fire occurrence statistics. PREFER will produce also seasonal fire risk maps by combining the seasonal hazard data with vulnerability and exposure maps. Finally, Prescribed Burning (PB) represents the controlled application of fire to vegetation under specific environmental conditions to attain planned resource management objectives. The main objective of the PREFER service for PB is to support the user in the identification of the areas and the time, that is where and when, the PB practice is applicable in a secure way. The main innovation, taking into account the results previously obtained in the frame work of other European projects (FIREPARADOX), will be the integration of the advanced remote sensing techniques that have not yet been developed for the problem under study, aiming at developing an index capable to provide the right time to intervene with the PB in the area of interest.
30 CFR 57.4104 - Combustible waste.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and... liquids, shall not accumulate in quantities that could create a fire hazard. (b) Waste or rags containing...
30 CFR 57.4104 - Combustible waste.
Code of Federal Regulations, 2012 CFR
2012-07-01
... flammable or combustible liquids that could create a fire hazard shall be placed in the following containers... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and...
30 CFR 57.4104 - Combustible waste.
Code of Federal Regulations, 2011 CFR
2011-07-01
... flammable or combustible liquids that could create a fire hazard shall be placed in the following containers... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and...
30 CFR 57.4104 - Combustible waste.
Code of Federal Regulations, 2013 CFR
2013-07-01
... flammable or combustible liquids that could create a fire hazard shall be placed in the following containers... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and...
30 CFR 57.4104 - Combustible waste.
Code of Federal Regulations, 2014 CFR
2014-07-01
... flammable or combustible liquids that could create a fire hazard shall be placed in the following containers... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and...
ERIC Educational Resources Information Center
Wallace, Glenda
2002-01-01
Provides information about the Firewise Program whose goal is to assist people to become more fire-aware and better prepared for the effects of wildfire on property. Discusses why there are so many wildfires and what can be done. Includes the Wildland Fire Risk and Hazard Severity Assessment Form. (KHR)
46 CFR 194.15-7 - Fire protection.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Fire protection. 194.15-7 Section 194.15-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS HANDLING, USE, AND CONTROL OF EXPLOSIVES AND OTHER HAZARDOUS MATERIALS Chemistry Laboratory and Scientific Laboratory...
46 CFR 194.15-7 - Fire protection.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false Fire protection. 194.15-7 Section 194.15-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS HANDLING, USE, AND CONTROL OF EXPLOSIVES AND OTHER HAZARDOUS MATERIALS Chemistry Laboratory and Scientific Laboratory...
Building Codes and Regulations.
ERIC Educational Resources Information Center
Fisher, John L.
The hazard of fire is of great concern to libraries due to combustible books and new plastics used in construction and interiors. Building codes and standards can offer architects and planners guidelines to follow but these standards should be closely monitored, updated, and researched for fire prevention. (DS)
Critical safety assurance factors for manned spacecraft - A fire safety perspective
NASA Technical Reports Server (NTRS)
Rodney, George A.
1990-01-01
Safety assurance factors for manned spacecraft are discussed with a focus on the Space Station Freedom. A hazard scenario is provided to demonstrate a process commonly used by safety engineers and other analysts to identify onboard safety risks. Fire strategies are described, including a review of fire extinguishing agents being considered for the Space Station. Lessons learned about fire safety technology in other areas are also noted. NASA and industry research on fire safety applications is discussed. NASA's approach to ensuring safety for manned spacecraft is addressed in the context of its multidiscipline program.
Cannon, Susan H.; DeGraff, Jerry
2009-01-01
In southern California and the intermountain west of the USA, debris flows generated from recently-burned basins pose significant hazards. Increases in the frequency and size of wildfires throughout the western USA can be attributed to increases in the number of fire ignitions, fire suppression practices, and climatic influences. Increased urbanization throughout the western USA, combined with the increased wildfire magnitude and frequency, carries with it the increased threat of subsequent debris-flow occurrence. Differences between rainfall thresholds and empirical debris-flow susceptibility models for southern California and the intermountain west indicate a strong influence of climatic and geologic settings on post-fire debris-flow potential. The linkages between wildfires, debris-flow occurrence, and global warming suggests that the experiences in the western United States are highly likely to be duplicated in many other parts of the world, and necessitate hazard assessment tools that are specific to local climates and physiographies.
Industrial accidents triggered by lightning.
Renni, Elisabetta; Krausmann, Elisabeth; Cozzani, Valerio
2010-12-15
Natural disasters can cause major accidents in chemical facilities where they can lead to the release of hazardous materials which in turn can result in fires, explosions or toxic dispersion. Lightning strikes are the most frequent cause of major accidents triggered by natural events. In order to contribute towards the development of a quantitative approach for assessing lightning risk at industrial facilities, lightning-triggered accident case histories were retrieved from the major industrial accident databases and analysed to extract information on types of vulnerable equipment, failure dynamics and damage states, as well as on the final consequences of the event. The most vulnerable category of equipment is storage tanks. Lightning damage is incurred by immediate ignition, electrical and electronic systems failure or structural damage with subsequent release. Toxic releases and tank fires tend to be the most common scenarios associated with lightning strikes. Oil, diesel and gasoline are the substances most frequently released during lightning-triggered Natech accidents. Copyright © 2010 Elsevier B.V. All rights reserved.
Sikalidis, Constantine; Mitrakas, Manassis
2006-01-01
The up to 20 wt% addition of the Electric Arc Furnace Dust (EAFD) hazardous waste on the properties of extruded clay-based ceramic building products fired at various temperatures (850 to 1050 degrees C), as well as of dolomite-concrete products was investigated. Chemical, mineralogical and particle size distribution analyses were performed in order to characterize the used EAFD. The results showed that the ceramic specimens prepared had water absorption, firing shrinkage, apparent density, mechanical strength, colour and leaching behaviour within accepted limits. Addition of 7.5 to 15 wt% EAFD presented improved properties, while 20 wt% seems to be the upper limit. Dolomite-concrete specimens were prepared by vibration and press-forming of mixtures containing cement, sand, dolomite, EAFD and water. Modulus of rupture values were significantly increased by the addition of EAFD. The leaching tests showed stabilization of all toxic metals within the sintered ceramic structure, while the leaching behaviour of lead in dolomite-concrete products needs further detailed study.
Multivariate statistical analysis of wildfires in Portugal
NASA Astrophysics Data System (ADS)
Costa, Ricardo; Caramelo, Liliana; Pereira, Mário
2013-04-01
Several studies demonstrate that wildfires in Portugal present high temporal and spatial variability as well as cluster behavior (Pereira et al., 2005, 2011). This study aims to contribute to the characterization of the fire regime in Portugal with the multivariate statistical analysis of the time series of number of fires and area burned in Portugal during the 1980 - 2009 period. The data used in the analysis is an extended version of the Rural Fire Portuguese Database (PRFD) (Pereira et al, 2011), provided by the National Forest Authority (Autoridade Florestal Nacional, AFN), the Portuguese Forest Service, which includes information for more than 500,000 fire records. There are many multiple advanced techniques for examining the relationships among multiple time series at the same time (e.g., canonical correlation analysis, principal components analysis, factor analysis, path analysis, multiple analyses of variance, clustering systems). This study compares and discusses the results obtained with these different techniques. Pereira, M.G., Trigo, R.M., DaCamara, C.C., Pereira, J.M.C., Leite, S.M., 2005: "Synoptic patterns associated with large summer forest fires in Portugal". Agricultural and Forest Meteorology. 129, 11-25. Pereira, M. G., Malamud, B. D., Trigo, R. M., and Alves, P. I.: The history and characteristics of the 1980-2005 Portuguese rural fire database, Nat. Hazards Earth Syst. Sci., 11, 3343-3358, doi:10.5194/nhess-11-3343-2011, 2011 This work is supported by European Union Funds (FEDER/COMPETE - Operational Competitiveness Programme) and by national funds (FCT - Portuguese Foundation for Science and Technology) under the project FCOMP-01-0124-FEDER-022692, the project FLAIR (PTDC/AAC-AMB/104702/2008) and the EU 7th Framework Program through FUME (contract number 243888).
NASA Astrophysics Data System (ADS)
Saputra, Agus Dwi; Setiabudidaya, Dedi; Setyawan, Dwi; Khakim, M. Yusup Nur; Iskandar, Iskhaq
2017-07-01
Forest fire, classified as a natural hazard or human-induced hazard, has negative impacts on humans. These negative impacts are including economic loss, health problems, transportation disruption and land degradation or even biodiversity loss. During 2015, forest fire had occurred at the Merang-Kepahyang peat forest that has a total area of about 69.837,00 ha. In order to set a rehabilitation plan for recovering the impact of forest fire, information on the total burnscar area and severity level is required. In this study, the total burnscar area and severity level is evaluated using a calculation on the Normalized Burning Ratio (NBR) Index. The calculation is based on the Near Infra Red (NIR) and Short Wave Infra Red (SWIR) of the satellite imageries from LANDSAT. The images of pre-and post-fire are used to evaluate the severity level, which is defined as a difference in NBR Index of pre- and post-fire. It is found that about 42.906,00 ha of the total area of Merang-Kepahyang peat area have been fired in 2015. These burned area are classified into four categories, i.e., unburned, low, extreme and moderate extreme. By overlying the spatial map of burning level with other thematic maps, it is expected that strategy for rehabilitation plan can be well developed.
Dow, Christopher B; Collins, Brandon M; Stephens, Scott L
2016-03-01
Finding novel ways to plan and implement landscape-level forest treatments that protect sensitive wildlife and other key ecosystem components, while also reducing the risk of large-scale, high-severity fires, can prove to be difficult. We examined alternative approaches to landscape-scale fuel-treatment design for the same landscape. These approaches included two different treatment scenarios generated from an optimization algorithm that reduces modeled fire spread across the landscape, one with resource-protection constrains and one without the same. We also included a treatment scenario that was the actual fuel-treatment network implemented, as well as a no-treatment scenario. For all the four scenarios, we modeled hazardous fire potential based on conditional burn probabilities, and projected fire emissions. Results demonstrate that in all the three active treatment scenarios, hazardous fire potential, fire area, and emissions were reduced by approximately 50 % relative to the untreated condition. Results depict that incorporation of constraints is more effective at reducing modeled fire outputs, possibly due to the greater aggregation of treatments, creating greater continuity of fuel-treatment blocks across the landscape. The implementation of fuel-treatment networks using different planning techniques that incorporate real-world constraints can reduce the risk of large problematic fires, allow for landscape-level heterogeneity that can provide necessary ecosystem services, create mixed forest stand structures on a landscape, and promote resilience in the uncertain future of climate change.
The Redesigned Hazard Mapping System (HMS) for Fire and Smoke Analysis
NASA Astrophysics Data System (ADS)
Ruminski, M.; Cheng, Z.; Salemi, T.
2017-12-01
The HMS thru November 2016 incorporated a wide variety of satellite data for use in fire and smoke detection, including 30 minute interval GOES-East and GOES-West, five AVHRR satellites (NOAA and METOP) and MODIS Aqua/Terra. NESDIS' Satellite Analysis Branch (SAB) analysts utilize the HMS to analyze and quality control the automated fire detections from each of the sensors and create the fire/smoke products to enable the users to mitigate disasters and environmental hazards. The new HMS design eliminates the inefficiencies and increases the accuracy of the fire/smoke analysis. The new system has the capability to display higher resolution data available from VIIRS and other future sensors while maintaining individual pixel integrity which improves the representation of fire size. This benefits the input to smoke forecast models and may possibly be useful as input for fire spread models. The new system also provides greater analysis control of layers and display properties and allows for the display of all GOES images, even when in Rapid Scan Operations (RSO) mode. To enhance the efficiency and improve the accuracy of the fire and smoke product, the new HMS eliminates the sector boundaries that the old HMS used as part of the GUI and now displays the full analysis domain (North and Central America, Caribbean and Hawaii). There is also now the functionality to edit smoke plumes on a finer scale. In the presentation we will highlight the new features of the updated HMS.
Singh, Ashish; Spak, Scott N.; Stone, Elizabeth A.; Downard, Jared; Bullard, Robert; Pooley, Mark; Kostle, Pamela A.; Mainprize, Matthew W.; Wichman, Michael D.; Peters, Thomas; Beardsley, Douglas; Stanier, Charles O.
2015-01-01
The Iowa City Landfill in eastern Iowa, United States, experienced a fire lasting 18 days in 2012, in which a drainage layer of over 1 million shredded tires burned, generating smoke that impacted the surrounding metropolitan area of 130,000 people. This emergency required air monitoring, risk assessment, dispersion modeling, and public notification. This paper quantifies the impact of the fire on local air quality and proposes a monitoring approach and an Air Quality Index (AQI) for use in future tire fires and other urban fires. Individual fire pollutants are ranked for acute and cancer relative risks using hazard ratios, with the highest acute hazard ratios attributed to SO2, particulate matter, and aldehydes. Using a dispersion model in conjunction with the new AQI, we estimate that smoke concentrations reached unhealthy outdoor levels for sensitive groups out to distances of 3.1 km and 18 km at 24-h and 1-h average times, respectively. Modeled and measured concentrations of PM2.5 from smoke and other compounds such as VOCs and benzo[a]pyrene are presented at a range of distances and averaging times, and the corresponding cancer risks are discussed. Through reflection on the air quality response to the event, consideration of cancer and acute risks, and comparison to other tire fires, we recommend that all landfills with shredded tire liners plan for hazmat fire emergencies. A companion paper presents emission factors and detailed smoke characterization. PMID:25624787
Singh, Ashish; Spak, Scott N; Stone, Elizabeth A; Downard, Jared; Bullard, Robert; Pooley, Mark; Kostle, Pamela A; Mainprize, Matthew W; Wichman, Michael D; Peters, Thomas; Beardsley, Douglas; Stanier, Charles O
2015-03-01
The Iowa City Landfill in eastern Iowa, United States, experienced a fire lasting 18 days in 2012, in which a drainage layer of over 1 million shredded tires burned, generating smoke that impacted the surrounding metropolitan area of 130,000 people. This emergency required air monitoring, risk assessment, dispersion modeling, and public notification. This paper quantifies the impact of the fire on local air quality and proposes a monitoring approach and an Air Quality Index (AQI) for use in future tire fires and other urban fires. Individual fire pollutants are ranked for acute and cancer relative risks using hazard ratios, with the highest acute hazard ratios attributed to SO 2 , particulate matter, and aldehydes. Using a dispersion model in conjunction with the new AQI, we estimate that smoke concentrations reached unhealthy outdoor levels for sensitive groups out to distances of 3.1 km and 18 km at 24-h and 1-h average times, respectively. Modeled and measured concentrations of PM 2.5 from smoke and other compounds such as VOCs and benzo[a]pyrene are presented at a range of distances and averaging times, and the corresponding cancer risks are discussed. Through reflection on the air quality response to the event, consideration of cancer and acute risks, and comparison to other tire fires, we recommend that all landfills with shredded tire liners plan for hazmat fire emergencies. A companion paper presents emission factors and detailed smoke characterization.
Development of fire test methods for airplane interior materials
NASA Technical Reports Server (NTRS)
Tustin, E. A.
1978-01-01
Fire tests were conducted in a 737 airplane fuselage at NASA-JSC to characterize jet fuel fires in open steel pans (simulating post-crash fire sources and a ruptured airplane fuselage) and to characterize fires in some common combustibles (simulating in-flight fire sources). Design post-crash and in-flight fire source selections were based on these data. Large panels of airplane interior materials were exposed to closely-controlled large scale heating simulations of the two design fire sources in a Boeing fire test facility utilizing a surplused 707 fuselage section. Small samples of the same airplane materials were tested by several laboratory fire test methods. Large scale and laboratory scale data were examined for correlative factors. Published data for dangerous hazard levels in a fire environment were used as the basis for developing a method to select the most desirable material where trade-offs in heat, smoke and gaseous toxicant evolution must be considered.
49 CFR 175.9 - Special aircraft operations.
Code of Federal Regulations, 2014 CFR
2014-10-01
... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION HAZARDOUS MATERIALS REGULATIONS CARRIAGE BY AIRCRAFT General...) Exceptions. This subchapter does not apply to the following materials used for special aircraft operations... aircraft. (4) Hazardous materials are carried and used during dedicated air ambulance, fire fighting, or...
49 CFR 175.9 - Special aircraft operations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION HAZARDOUS MATERIALS REGULATIONS CARRIAGE BY AIRCRAFT General...) Exceptions. This subchapter does not apply to the following materials used for special aircraft operations... aircraft. (4) Hazardous materials are carried and used during dedicated air ambulance, fire fighting, or...
49 CFR 175.9 - Special aircraft operations.
Code of Federal Regulations, 2013 CFR
2013-10-01
... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION HAZARDOUS MATERIALS REGULATIONS CARRIAGE BY AIRCRAFT General...) Exceptions. This subchapter does not apply to the following materials used for special aircraft operations... aircraft. (4) Hazardous materials are carried and used during dedicated air ambulance, fire fighting, or...
40 CFR 267.56 - What are the required emergency procedures for the emergency coordinator?
Code of Federal Regulations, 2010 CFR
2010-07-01
... hazardous surface water run-off from water or chemical agents used to control fire and heat-induced...) The extent of injuries, if any. (vi) The possible hazards to human health or the environment outside...
16 CFR § 1500.15 - Labeling of fire extinguishers.
Code of Federal Regulations, 2013 CFR
2013-01-01
... the statement of hazard “Dangerous gas formed when used to extinguish flame or on contact with heat... in § 1500.3(c)(1), the signal word “Danger” and the statement of hazard “Poisonous gases formed when...
David J. Ganz; David S. Saah; Klaus Barber; Mark Nechodom
2007-01-01
The fire behavior modeling described here, conducted as part of the Biomass to Energy (B2E) life cycle assessment, is funded by the California Energy Commission to evaluate the potential net benefits associated with treating and utilizing forest biomass. The B2E project facilitates economic, environmental, energy, and effectiveness assessments of the potential public...
Eric E. Knapp
2015-01-01
Dead trees play an important role in forests, with snags and coarse woody debris (CWD) used by many bird and mammal species for nesting, resting, or foraging. However, too much dead wood can also contribute to extreme fire behavior. This tension between dead wood as habitat and dead wood as fuel has raised questions about appropriate quantities in fire-dependent...
14 CFR 27.859 - Heating systems.
Code of Federal Regulations, 2010 CFR
2010-01-01
.... Except for heaters which incorporate designs to prevent hazards in the event of fuel leakage in the... locations ensuring prompt detection of fire in the heater region. (2) Fire extinguisher systems that provide... shrouds so that no leakage from those components can enter the ventilating airstream. (k) Drains. There...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control... stopping the flow of fuel at the source and shall be located and maintained to minimize fire hazards. This...
30 CFR 56.4102 - Spillage and leakage.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and... liquid spillage or leakage shall be removed in a timely manner or controlled to prevent a fire hazard. ...
30 CFR 57.4102 - Spillage and leakage.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and... liquid spillage or leakage shall be removed in a timely manner or controlled to prevent a fire hazard. ...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and Control... stopping the flow of fuel at the source and shall be located and maintained to minimize fire hazards. This...
36 CFR 28.11 - Nonconforming uses.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Nonconforming uses. 28.11 Section 28.11 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR FIRE... insurance practices), destroyed or rendered a hazard, whether by fire, natural disaster, abandonment or...
Prescribed burning in southwestern ponderosa pine
Stephen S Sackett; Sally M Haase; Michael G Harrington
1996-01-01
Prescribed burning is an effective way of restoring the fire process to ponderosa pine (Pinus ponderosa Dougl. ex Laws.) ecosystems of the Southwest. If used judiciously, fire can provide valuable effects for hazard reduction, natural regeneration, thinning, vegetation revitalization, and in general, better forest health. Relatively short burning...
36 CFR 28.11 - Nonconforming uses.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 36 Parks, Forests, and Public Property 1 2011-07-01 2011-07-01 false Nonconforming uses. 28.11 Section 28.11 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR FIRE... insurance practices), destroyed or rendered a hazard, whether by fire, natural disaster, abandonment or...
30 CFR 77.1100 - Fire protection; training and organization.
Code of Federal Regulations, 2010 CFR
2010-07-01
....1100 Section 77.1100 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF... facilities and equipment shall be provided commensurate with the potential fire hazards at each structure...
NASA Astrophysics Data System (ADS)
Tepley, A. J.; Veblen, T. T.; Perry, G.; Anderson-Teixeira, K. J.
2015-12-01
In the face of on-going climatic warming and land-use change, there is growing concern that temperate forest landscapes could be near a tipping point where relatively small changes to the fire regime or altered post-fire vegetation dynamics could lead to extensive conversion to shrublands or savannas. To evaluate vulnerability and resilience to such conversion, we develop a simple model based on three factors we hypothesize to be key in predicting temperate forest responses to changing fire regimes: (1) the hazard rate (i.e., the probability of burning in the next year given the time since the last fire) in closed-canopy forests, (2) the hazard rate for recently-burned, open-canopy vegetation, and (3) the time to redevelop canopy closure following fire. We generate a response surface representing the proportions of the landscape potentially supporting closed-canopy forest and non-forest vegetation under nearly all combinations of these three factors. We then place real landscapes on this response surface to assess the type and magnitude of changes to the fire regime that would drive extensive forest loss. We show that the deforestation of much of New Zealand that followed initial human colonization and the introduction of a new ignition source ca. 750 years ago was essentially inevitable due to the slow rate of forest recovery after fire and the high flammability of post-fire vegetation. In North America's Pacific Northwest, by contrast, a predominantly forested landscape persisted despite two periods of widespread burning in the recent past due in large part to faster post-fire forest recovery and less pronounced differences in flammability between forests and the post-fire vegetation. We also assess the factors that could drive extensive deforestation in other regions to identify where management could reduce this potential and to guide field and modeling work to better understand the responses and ecological feedbacks to changing fire regimes.
WebGIS Platform Adressed to Forest Fire Management Methodologies
NASA Astrophysics Data System (ADS)
André Ramos-Simões, Nuno; Neto Paixão, Helena Maria; Granja Martins, Fernando Miguel; Pedras, Celestina; Lança, Rui; Silva, Elisa; Jordán, António; Zavala, Lorena; Soares, Cristina
2015-04-01
Forest fires are one of the natural disasters that causes more damages in nature, as well as high material costs, and sometimes, a significant losses in human lives. In summer season, when high temperatures are attained, fire may rapidly progress and destroy vast areas of forest and also rural and urban areas. The forest fires have effect on forest species, forest composition and structure, soil properties and soil capacity for nutrient retention. In order to minimize the negative impact of the forest fires in the environment, many studies have been developed, e.g. Jordán et al (2009), Cerdà & Jordán (2010), and Gonçalves & Vieira (2013). Nowadays, Remote Sensing (RS) and Geographic Information System (GIS) technologies are used as support tools in fire management decisions, namely during the fire, but also before and after. This study presents the development of a user-friendly WebGIS dedicated to share data, maps and provide updated information on forest fire management for stakeholders in Iberia Peninsula. The WebGIS platform was developed with ArcGIS Online, ArcGIS for Desktop; HyperText Markup Language (HTML) and Javascript. This platform has a database that includes spatial and alphanumeric information, such as: origin, burned areas, vegetation change over time, terrain natural slope, land use, soil erosion and fire related hazards. The same database contains also the following relevant information: water sources, forest tracks and traffic ways, lookout posts and urban areas. The aim of this study is to provide the authorities with a tool to assess risk areas and manage more efficiently forest fire hazards, giving more support to their decisions and helping the populations when facing this kind of phenomena.
NASA Astrophysics Data System (ADS)
Ruminski, M.; Cheng, Z.; Salemi, T.
2016-12-01
The HMS incorporates a wide variety of satellite data for use in fire and smoke detection, including 30 minute interval GOES-East and GOES-West, five AVHRR satellites (NOAA and METOP) and MODIS Aqua/Terra. NESDIS' Satellite Analysis Branch (SAB) analysts utilize the HMS to analyze and quality control the automated fire detections from each of the sensors and create the fire/smoke products to enable the users to mitigate disasters and environmental hazards. The new HMS design eliminates the inefficiencies and increases the accuracy of the fire/smoke analysis. The new system has the capability to display higher resolution data available from VIIRS while maintaining individual pixel integrity which improves the representation of fire size. This will benefit the input to smoke forecast models and may possibly be useful as input for fire spread models. An analysis of all VIIRS Active Fire (AF) locations compared to the operational HMS fire analysis for all of 2015 over North America will be presented that will provide an estimate of the impact of this new data set. Results will be presented for regional and seasonal impact. The new system also provides greater analysis control of layers and display properties and will allow for the display of all GOES images, even when in Rapid Scan Operations (RSO) mode. To enhance the efficiency and improve the accuracy of the fire and smoke product, the display of the new HMS eliminates the sector boundaries to display full analysis domain (North and Central America, Caribbean and Hawaii) and has functionality to edit plumes on a finer scale. In the presentation we will highlight the new features of the updated HMS.
Fire behavior and risk analysis in spacecraft
NASA Technical Reports Server (NTRS)
Friedman, Robert; Sacksteder, Kurt R.
1988-01-01
Practical risk management for present and future spacecraft, including space stations, involves the optimization of residual risks balanced by the spacecraft operational, technological, and economic limitations. Spacecraft fire safety is approached through three strategies, in order of risk: (1) control of fire-causing elements, through exclusion of flammable materials for example; (2) response to incipient fires through detection and alarm; and (3) recovery of normal conditions through extinguishment and cleanup. Present understanding of combustion in low gravity is that, compared to normal gravity behavior, fire hazards may be reduced by the absence of buoyant gas flows yet at the same time increased by ventilation flows and hot particle expulsion. This paper discusses the application of low-gravity combustion knowledge and appropriate aircraft analogies to fire detection, fire fighting, and fire-safety decisions for eventual fire-risk management and optimization in spacecraft.