Sample records for fire protection jacket

  1. Fire Protection Jacket

    NASA Technical Reports Server (NTRS)

    1991-01-01

    NERAC, Inc., Tolland, CT, aided Paul Monroe Engineering, Orange, CA, in the development of their PC1200 Series Fire Protection Jacket that protects the oil conduit system on an offshore drilling platform from the intense hydrocarbon fires that cause buckling and could cause structural failure of the platform. The flame-proof jacketing, which can withstand temperatures of 2000 degrees Fahrenheit for four hours or more, was developed from a combination of ceramic cloth (similar to the ceramic in Space Shuttle tiles), and laminates used in space suits.

  2. 49 CFR 179.18 - Thermal protection systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... fire effects on and heat flux through tank discontinuities, protective housings, underframes, metal jackets, insulation, and thermal protection. A complete record of each analysis shall be made, retained...

  3. 49 CFR 179.18 - Thermal protection systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... fire effects on and heat flux through tank discontinuities, protective housings, underframes, metal jackets, insulation, and thermal protection. A complete record of each analysis shall be made, retained...

  4. 49 CFR 179.18 - Thermal protection systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... fire effects on and heat flux through tank discontinuities, protective housings, underframes, metal jackets, insulation, and thermal protection. A complete record of each analysis shall be made, retained...

  5. 49 CFR 179.18 - Thermal protection systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... fire effects on and heat flux through tank discontinuities, protective housings, underframes, metal jackets, insulation, and thermal protection. A complete record of each analysis shall be made, retained...

  6. 49 CFR 179.18 - Thermal protection systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... analysis must consider the fire effects on and heat flux through tank discontinuities, protective housings, underframes, metal jackets, insulation, and thermal protection. A complete record of each analysis shall be...

  7. A systematic examination of the bone destruction pattern of the two-shot technique

    PubMed Central

    Stoetzer, Marcus; Stoetzer, Carsten; Rana, Majeed; Zeller, Alexander; Hanke, Alexander; Gellrich, Nils-Claudius; von See, Constantin

    2014-01-01

    Introduction: The two-shot technique is an effective stopping power method. The precise mechanisms of action on the bone and soft-tissue structures of the skull; however, remain largely unclear. The aim of this study is to compare the terminal ballistics of the two-shot and single-shot techniques. Materials and Methods: 40 fresh pigs’ heads were randomly divided into 4 groups (n = 10). Either a single shot or two shots were fired at each head with a full metal jacket or a semi-jacketed bullet. Using thin-layer computed tomography and photography, the diameter of the destruction pattern and the fractures along the bullet path were then imaged and assessed. Results: A single shot fired with a full metal jacket bullet causes minor lateral destruction along the bullet path. With two shots fired with a full metal jacket bullet, however, the maximum diameter of the bullet path is significantly greater (P < 0.05) than it is with a single shot fired with a full metal jacket bullet. In contrast, the maximum diameter with a semi-jacketed bullet is similar with the single-shot and two-shot techniques. Conclusion: With the two-shot technique, a full metal jacket bullet causes a destruction pattern that is comparable to that of a single shot fired with a semi-jacketed bullet. PMID:24812454

  8. Fire fighting and its influence on the body.

    PubMed

    Rossi, René

    2003-08-15

    Working conditions for fire fighters can be described according to the environment temperature and the incident radiant heat flux. Measurements for this study in buildings for fire fighting training have shown that fire fighters are typically exposed to radiant heat fluxes of between 5 and 10 kWm(-2) during this kind of exercise. The heat load can nevertheless be much higher. In one case, 42 kWm(-2) was measured. The temperatures reached between 100 and 190 degrees C at 1 m above ground, going up to 278 degrees C in one case. Human trials have been performed with 17 fire fighters. After exercises (about 15 min) in a heated room, the mean core temperature of the fire fighters rose by 0.6 degrees C with a surrounding temperature of 31 degrees C and 1.0 degrees C with 38 degrees C. The sweat production varied from 0.7 to 2.1 lh(-1); 16% to 45% of sweat remained in the clothing layers. During the exercises in the training buildings, a mean of 48 degrees C has been measured between fire fighters' clothing and workwear. These conditions lead to an increase of the relative humidity in all the jackets up to 100%. When the fire fighters came out of the fire, the humidity remained at this level in the PVC coated jackets while it was in some cases strongly reduced in breathable jackets.

  9. Fire related hazards of cables: The Canadian position development of fire resistant inside wiring cable

    NASA Astrophysics Data System (ADS)

    Hartley, M. D.; Jaques, R. E.

    1986-11-01

    The Canadian Electrical Code and the National Building Code in Canada recognize only two designations in regards to fire resistance of cables; cables for use in combustible (residential) buildings and cables for use in non-combustible buildings. The Test standard for cables for non-combustible buildings resembles IEEE-383. However, it is more severe; particularly for small nonarmoured cables such as Inside Wiring Cable. This forthcoming requirement has necessitated material and product development. Although an Inside Wiring cable modification of both insulation and jacket was undertaken, the large volume fraction of combustible material in the jacket vis a vis the insulation made it the area of greatest impact. The paper outlines the development and its effect on cable performance.

  10. Cooling techniques for turbojet pre-heater channels

    NASA Astrophysics Data System (ADS)

    Desaulty, M.; Troullot, P.; Coutor, S.

    1985-09-01

    Increases in the performance of turbojets with pre-heating are dependent upon technological research in the area of protection of the wall in pre-heater channels. The procedures used to cool the thermal protection jackets have undergone important improvements which have optimized performance, reduced weight and improved cooling efficiency. This report presents a comparison of the thermal protection jackets for several SNECMA engines, as well as the principal stages of development for the jacket from the design stages through static engines tests.

  11. 30 CFR 57.15020 - Life jackets and belts.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Life jackets and belts. 57.15020 Section 57.15020 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Protection Surface Only § 57.15020 Life jackets and belts. Life jackets or belts shall be worn where there is...

  12. 30 CFR 57.15020 - Life jackets and belts.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Life jackets and belts. 57.15020 Section 57.15020 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Protection Surface Only § 57.15020 Life jackets and belts. Life jackets or belts shall be worn where there is...

  13. 30 CFR 57.15020 - Life jackets and belts.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Life jackets and belts. 57.15020 Section 57.15020 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Protection Surface Only § 57.15020 Life jackets and belts. Life jackets or belts shall be worn where there is...

  14. 30 CFR 57.15020 - Life jackets and belts.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Life jackets and belts. 57.15020 Section 57.15020 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Protection Surface Only § 57.15020 Life jackets and belts. Life jackets or belts shall be worn where there is...

  15. 30 CFR 57.15020 - Life jackets and belts.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Life jackets and belts. 57.15020 Section 57.15020 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Protection Surface Only § 57.15020 Life jackets and belts. Life jackets or belts shall be worn where there is...

  16. A study of ignition by rifle bullets

    Treesearch

    Mark A. Finney; Trevor B. Maynard; Sara S. McAllister; Ian J. Grob

    2013-01-01

    Experiments were conducted to examine the potential for rifle bullets to ignite organic matter after impacting a hard surface. The tests were performed using a variety of common cartridges (7.62x51, 7.62x39, 7.62x54R, and 5.56x45) and bullet materials (steel core, lead core, solid copper, steel jacket, and copper jacket). Bullets were fired at a steel plate that...

  17. The Impact of Training and Equipment at the Battle of Attu, Aleutian Campaign - Historical Study and Current Perspective

    DTIC Science & Technology

    2015-06-12

    Waterproofed - Not durable past a few days Jacket Reversible ski parka (R) - Hood - More protection from wind and rain Arctic field jacket (I...No hood - Less protection from wind and rain Sweater Recommended - Necessity in extreme cold based on Alaska experience Not issued - Not

  18. Computed tomographic evaluation to determine efficacy of euthanasia of yearling feedlot cattle by use of various firearm-ammunition combinations.

    PubMed

    Thomson, Daniel U; Wileman, Benjamin W; Rezac, Darrel J; Miesner, Matt D; Johnson-Neitman, Jennifer L; Biller, David S

    2013-11-01

    To evaluate with CT the efficacy of various combinations of firearms and ammunitions to penetrate and disrupt the brain tissue of cadaveric heads of feedlot steers. 42 fresh cadaveric heads of 12- to 18-month-old Bos taurus steers. For each of 7 combinations of firearms and ammunitions (.22-caliber rifle firing a long rifle 30-grain plated lead solid- or hollow-point round, .223-caliber carbine firing a 50-grain ballistic-tip round, 9-mm pistol firing a 124-grain total metal jacket round, .45-caliber automatic Colt pistol [ACP] firing a 230-grain full metal jacket round, and 12-gauge shotgun firing a 2.75-inch 1.25-ounce No. 4 birdshot shell or a 1-ounce rifled slug), 6 cadaveric heads were shot at an identical distance (3 m), angle, and anatomic location. Heads were scanned with third-generation CT, and images were evaluated to determine extent of penetration, projectile fragmentation, cranial fracture, and likelihood of instantaneous death (≥ 30% destruction of brain tissue or a brainstem lesion). RESULTS-41 of 42 skulls were penetrated by the projectile. Instantaneous death was considered a likely consequence for 83% (25/30) of heads shot with a rifle-fired .22-caliber solid-point round, pistol-fired .45-caliber ACP round, carbine-fired .223-caliber round, and shotgun-fired birdshot and slug. Of the 18 heads shot with pistol-fired 9-mm and .45-caliber ACP rounds and rifle-fired .22-caliber hollow-point rounds, only 6 had brainstem lesions. CONCLUSIONS AND CLINICAL RELEVANCE-Results suggested that gunshots delivered by all firearm-ammunition combinations except rifle-fired .22-caliber hollow-point rounds and pistol-fired 9-mm rounds were viable options for euthanasia of feedlot cattle.

  19. The confining effectiveness of NiTiNb and NiTi SMA wire jackets for concrete

    NASA Astrophysics Data System (ADS)

    Choi, Eunsoo; Chung, Young-Soo; Choi, Jun-Hyeok; Kim, Hong-Taek; Lee, Hacksoo

    2010-03-01

    The purpose of this study is to assess the confining effectiveness of shape memory alloy (SMA) wire jackets for concrete. The performance of SMA wire jackets was compared to that of steel jackets. A prestrained martensitic SMA wire was wrapped around a concrete cylinder and then heated by a heating jacket. In the process, a confining stress around the cylinder was developed in the SMA wire due to the shape memory effect; this jacketing method can increase the strength and ductility of the cylinder under an axial compressive load. In this study, NiTi and NiTiNb SMA wires of 1.0 mm in diameter were used for the confinement. Recovery tests were conducted on the wires to assess their recovery and residual stress. The confinement by SMA wire jackets increased the strength slightly and greatly increased the ductility compared to the strength and ductility of plain concrete cylinders. The NiTiNb SMA wire jacket showed better performance than that of the NiTi SMA wire jacket. The confining effectiveness of the SMA wire jackets of this study was estimated to be similar to that of the steel jackets. This study showed the potential of the SMA wire jacketing method to retrofit reinforced concrete columns and protect them from seismic risks.

  20. Anaphylaxis

    MedlinePlus

    ... Bees Wasps Hornets Yellow jackets Fire ants Medicines Antibiotics and antiseizure medicines are some of the more common medicines that cause anaphylaxis. However, any medicine, even aspirin and other nonsteroidal anti-inflammatory drugs, have the potential to cause severe reactions. ...

  1. Vacuum jacketed composite propulsion feedlines for cryogenic launch and space vehicles, volume 1. [development of glass fiber composite for strength and protection from handling damage

    NASA Technical Reports Server (NTRS)

    Spond, D. E.; Laintz, D. J.; Hall, C. A.; Dulaigh, D. E.

    1974-01-01

    Thin metallic liners that provide leak-free service in cryogenic propulsion systems are overwrapped with a glass-fiber composite that provides strength and protection from handling damage. The resultant tube is lightweight, strong, and has a low thermal flux. The inside commodity flow line and the outside vacuum jacket were fabricated using this method. Several types of vacuum jackets were fabricated and tested at operating temperatures from 294 to 21 K (+70 to minus 423 F) and operating pressure up to 69 N/cm2 (100 psi). The primary objective of the program was to develop vacuum jacket concepts, using previously developed concepts for the inner line. All major program objectives were met resulting in a design concept that is adaptable to a wide range of aerospace vehicle requirements. Major items of development included convolution of thin metallic sections up to 46 cm (18 in.) in diameter, design and fabrication of an extremely lightweight tension membrane concept for the vacuum jacket, and analytical tools that predict the failure mode and levels.

  2. Viability of Bismuth as a Green Substitute for Lead in Jacketed .357 Magnum Revolver Bullets

    NASA Astrophysics Data System (ADS)

    Jenkins, Joel

    In seeking to develop environmentally friendly lead-free non-toxic bullets, the research ballistically evaluated the performance of copper-jacketed handgun bullets containing a pure bismuth core. The lead was first removed from 140 grain Hornady(TM) XTPRTM bullets of 38 caliber (.357 diameter) by melting. The empty jackets were then refilled with pure bismuth, including the forming of a correctly sized hollow-point cavity. Due to the lower density of bismuth as compared to lead, the bismuth-cored bullets consistently weighed 125 gains. Conveniently this allowed direct comparison to commercially available 125 grain Hornady(TM) XTPRTM lead-cored bullets of 38 caliber. Both bismuth-cored and lead-cored versions of the 125 grain bullets had identical nose dimensions and jacket material, the only dimensional difference being the bullet length below the cannelure. Shooting took place at an outdoor range using a 357 Magnum Ruger(TM) SP101RTM revolver with 3" barrel as the test weapon. FBI protocols were followed when firing through clothing, wallboard, plywood, steel plates and laminated glass. Wound paths and bullets were captured in ballistic gelatin, with data collected for velocity, penetration, expansion, and weight retention. Bismuth compared favorably with lead in all but the laminated glass test, where it under penetrated due to jacket separation.

  3. Contamination of firefighter personal protective equipment and skin and the effectiveness of decontamination procedures.

    PubMed

    Fent, Kenneth W; Alexander, Barbara; Roberts, Jennifer; Robertson, Shirley; Toennis, Christine; Sammons, Deborah; Bertke, Stephen; Kerber, Steve; Smith, Denise; Horn, Gavin

    2017-10-01

    Firefighters' skin may be exposed to chemicals via permeation/penetration of combustion byproducts through or around personal protective equipment (PPE) or from the cross-transfer of contaminants on PPE to the skin. Additionally, volatile contaminants can evaporate from PPE following a response and be inhaled by firefighters. Using polycyclic aromatic hydrocarbons (PAHs) and volatile organic compounds (VOCs) as respective markers for non-volatile and volatile substances, we investigated the contamination of firefighters' turnout gear and skin following controlled residential fire responses. Participants were grouped into three crews of twelve firefighters. Each crew was deployed to a fire scenario (one per day, four total) and then paired up to complete six fireground job assignments. Wipe sampling of the exterior of the turnout gear was conducted pre- and post-fire. Wipe samples were also collected from a subset of the gear after field decontamination. VOCs off-gassing from gear were also measured pre-fire, post-fire, and post-decon. Wipe sampling of the firefighters' hands and neck was conducted pre- and post-fire. Additional wipes were collected after cleaning neck skin. PAH levels on turnout gear increased after each response and were greatest for gear worn by firefighters assigned to fire attack and to search and rescue activities. Field decontamination using dish soap, water, and scrubbing was able to reduce PAH contamination on turnout jackets by a median of 85%. Off-gassing VOC levels increased post-fire and then decreased 17-36 min later regardless of whether field decontamination was performed. Median post-fire PAH levels on the neck were near or below the limit of detection (< 24 micrograms per square meter [µg/m 2 ]) for all positions. For firefighters assigned to attack, search, and outside ventilation, the 75 th percentile values on the neck were 152, 71.7, and 39.3 µg/m 2 , respectively. Firefighters assigned to attack and search had higher post-fire median hand contamination (135 and 226 µg/m 2 , respectively) than other positions (< 10.5 µg/m 2 ). Cleansing wipes were able to reduce PAH contamination on neck skin by a median of 54%.

  4. Occupational stress and strain in relation to personal protective equipment of Japanese firefighters assessed by a questionnaire.

    PubMed

    Son, Su-Young; Lee, Joo-Young; Tochihara, Yutaka

    2013-01-01

    The purpose of the present study was to elucidate differences in actual work environments, mobility and satisfaction between firefighters wearing aluminized and non-aluminized personal protective equipment (PPE), and to suggest a proper standard test method for Japanese firefighters' PPE. A survey from two cities in Japan (City A: aluminized PPE; City B: non aluminized PPE) was undertaken. A total of 525 firefighters from City A and 757 from City B participated. Firefighters spent 22.5 min (City A) and 27.3 min (City B) on average firefighting with the full set of PPE in one incident, but the heat strain experienced among firefighters from City A was twice that of firefighters from City B (57.5% and 28.4%). Firefighters spent 65.9 min on one incident and 24.2 min for suppression of fire with the full set of PPE on average. The toughest task that caused physical strain in City A was 'stair climbing' and in City B was 'drawing up a hose filled with water'. The most restricted body region due to PPE was the knee for both groups. Evaluations revealed that the aluminized fire jacket had worse ventilation and mobility than the non-aluminized, while the non-aluminized one received with more unfavorable evaluations for water resistance and maintainability.

  5. 46 CFR 176.204 - Permit to carry excursion party.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., survival craft, life jacket, fire safety, and manning standards applicable to a vessel in the service for... may carry, the crew required, any additional lifesaving or safety equipment required, the route for... waive the applicable minimum safety standards when issuing an excursion permit. In particular, a vessel...

  6. 46 CFR 115.204 - Permit to carry excursion party.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... jacket, fire safety, and manning standards applicable to a vessel in the service for which the excursion... crew required, any additional lifesaving or safety equipment required, the route for which the permit... applicable minimum safety standards when issuing an excursion permit. In particular, a vessel that is being...

  7. 46 CFR 176.204 - Permit to carry excursion party.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., survival craft, life jacket, fire safety, and manning standards applicable to a vessel in the service for... may carry, the crew required, any additional lifesaving or safety equipment required, the route for... waive the applicable minimum safety standards when issuing an excursion permit. In particular, a vessel...

  8. 46 CFR 115.204 - Permit to carry excursion party.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... jacket, fire safety, and manning standards applicable to a vessel in the service for which the excursion... crew required, any additional lifesaving or safety equipment required, the route for which the permit... applicable minimum safety standards when issuing an excursion permit. In particular, a vessel that is being...

  9. 46 CFR 176.204 - Permit to carry excursion party.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., survival craft, life jacket, fire safety, and manning standards applicable to a vessel in the service for... may carry, the crew required, any additional lifesaving or safety equipment required, the route for... waive the applicable minimum safety standards when issuing an excursion permit. In particular, a vessel...

  10. 46 CFR 115.204 - Permit to carry excursion party.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... jacket, fire safety, and manning standards applicable to a vessel in the service for which the excursion... crew required, any additional lifesaving or safety equipment required, the route for which the permit... applicable minimum safety standards when issuing an excursion permit. In particular, a vessel that is being...

  11. Condition assessment and determination of methods for evaluating corrosion damage in piles encapsulated in protective jackets on the Hampton Roads Bridge-Tunnel.

    DOT National Transportation Integrated Search

    2010-04-01

    The primary purpose of this study was to assess the condition of piles that had been encapsulated in fiberglass and mortar jackets on four bridges that are part of the Hampton Roads Bridge-Tunnel (HRBT). Since these four bridges contain a total of ap...

  12. Response of Nuclear Power Plant Instrumentation Cables Exposed to Fire Conditions.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muna, Alice Baca; LaFleur, Chris Bensdotter; Brooks, Dusty Marie

    This report presents the results of instrumentation cable tests sponsored by the US Nuclear Regulatory Commission (NRC) Office of Nuclear Regulatory Research and performed at Sandia National Laboratories (SNL). The goal of the tests was to assess thermal and electrical response behavior under fire-exposure conditions for instrumentation cables and circuits. The test objective was to assess how severe radiant heating conditions surrounding an instrumentation cable affect current or voltage signals in an instrumentation circuit. A total of thirty-nine small-scale tests were conducted. Ten different instrumentation cables were tested, ranging from one conductor to eight-twisted pairs. Because the focus of themore » tests was thermoset (TS) cables, only two of the ten cables had thermoplastic (TP) insulation and jacket material and the remaining eight cables were one of three different TS insulation and jacket material. Two instrumentation cables from previous cable fire testing were included, one TS and one TP. Three test circuits were used to simulate instrumentation circuits present in nuclear power plants: a 4–20 mA current loop, a 10–50 mA current loop and a 1–5 VDC voltage loop. A regression analysis was conducted to determine key variables affecting signal leakage time.« less

  13. Characterization of Textiles Used in Chefs' Uniforms for Protection Against Thermal Hazards Encountered in the Kitchen Environment.

    PubMed

    Zhang, Han; McQueen, Rachel H; Batcheller, Jane C; Ehnes, Briana L; Paskaluk, Stephen A

    2015-10-01

    Within the kitchen the potential for burn injuries arising from contact with hot surfaces, flames, hot liquid, and steam hazards is high. The chef's uniform can potentially offer some protection against such burns by providing a protective barrier between the skin and the thermal hazard, although the extent to which can provide some protection is unknown. The purpose of this study was to examine whether fabrics used in chefs' uniforms were able to provide some protection against thermal hazards encountered in the kitchen. Fabrics from chefs' jackets and aprons were selected. Flammability of single- and multiple-layered fabrics was measured. Effect of jacket type, apron and number of layers on hot surface, hot water, and steam exposure was also measured. Findings showed that all of the jacket and apron fabrics rapidly ignited when exposed to a flame. Thermal protection against hot surfaces increased as layers increased due to more insulation. Protection against steam and hot water improved with an impermeable apron in the system. For wet thermal hazards increasing the number of permeable layers can decrease the level of protection due to stored thermal energy. As the hands and arms are most at risk of burn injury increased insulation and water-impermeable barrier in the sleeves would improve thermal protection with minimal compromise to overall thermal comfort. © The Author 2015. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  14. Additional Studies on Clothing Treatments for Personal Protection against Biting Flies

    DTIC Science & Technology

    1979-09-01

    length Jackets with attached hoods, the separate hoods were made of mesh fabric consisting of polyester filaments that give some abrasion resistance and...conditions was carried out using a sling psychrometer and anemometer to give data on dry-bulb temperature, relative humidity and wind speed. Insect specimens...treated the experimental items. Mrs. J. Whalen made the Jackets and hoods. UNCLASSIFIED

  15. 49 CFR 178.57 - Specification 4L welded insulated cylinders.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... cylinder must be insulated. The insulating material must be fire resistant. The insulation on non-evacuated.... If a vacuum is maintained in the insulation space, the evacuated jacket must be designed for a... must be such that the total heat transfer, from the atmosphere at ambient temperature to the contents...

  16. 49 CFR 178.57 - Specification 4L welded insulated cylinders.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... cylinder must be insulated. The insulating material must be fire resistant. The insulation on non-evacuated.... If a vacuum is maintained in the insulation space, the evacuated jacket must be designed for a... must be such that the total heat transfer, from the atmosphere at ambient temperature to the contents...

  17. 49 CFR 178.57 - Specification 4L welded insulated cylinders.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... cylinder must be insulated. The insulating material must be fire resistant. The insulation on non-evacuated.... If a vacuum is maintained in the insulation space, the evacuated jacket must be designed for a... must be such that the total heat transfer, from the atmosphere at ambient temperature to the contents...

  18. 40 CFR 60.431 - Definitions and notations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Definitions and notations. 60.431 Section 60.431 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS..., package inserts, book jackets, market circulars, magazine inserts, and shopping news, Newspapers, magazine...

  19. 40 CFR 60.431 - Definitions and notations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Definitions and notations. 60.431 Section 60.431 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS..., package inserts, book jackets, market circulars, magazine inserts, and shopping news, Newspapers, magazine...

  20. 40 CFR 60.431 - Definitions and notations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Definitions and notations. 60.431 Section 60.431 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS..., package inserts, book jackets, market circulars, magazine inserts, and shopping news, Newspapers, magazine...

  1. 40 CFR 60.431 - Definitions and notations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Definitions and notations. 60.431 Section 60.431 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS..., package inserts, book jackets, market circulars, magazine inserts, and shopping news, Newspapers, magazine...

  2. 40 CFR 60.431 - Definitions and notations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Definitions and notations. 60.431 Section 60.431 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS..., package inserts, book jackets, market circulars, magazine inserts, and shopping news, Newspapers, magazine...

  3. Dynamic simulation of relief line during loss of insulation vacuum of the ITER cryoline

    NASA Astrophysics Data System (ADS)

    Badgujar, S.; Kosek, J.; Grillot, D.; Forgeas, A.; Sarkar, B.; Shah, N.; Choukekar, K.; Chang, H.-S.

    2017-12-01

    The ITER cryoline (CL) system consists of 37 types of vacuum jacketed transfer lines which forms a complex structured network with a total length of about 5 km, spread inside the Tokamak building, on a dedicated plant bridge and in the Cryoplant building/area. One of them, the low pressure relief line (RL) recovers helium discharged from process safety relief valves of the different cryogenic users and is sent it back to the Cryoplant via heater and recovery system. The process pipe diameters of the RL vary from DN 50 to DN 200 and the length is more than 1500 m. Loss of insulation vacuum (LIV) of a CL is one of the worst scenarios apart from LIV in Auxiliary Cold Boxes (ACBs). The Torus and Cryostat CL is chosen to simulate the virtual LIV and to study the anticipated behavior of the RL. Both helium LIV (LIV due to leak in helium pipe) and air LIV (LIV due to air ingress in outer vacuum jacket of the cryoline) with and without fire) have been simulated during this study. After the brief description of the CL system, the paper will describe the EcosimPro® model prepared for the dynamic study. The paper will also describe the results like minimum temperature of RL, mass flow and maximum pressure in the RL which are essentially used to choose the type and location of safety relief devices to protect the CL process pipes.

  4. Comparison of Gunshot Entrance Morphologies Caused by .40-Caliber Smith & Wesson, .380-Caliber, and 9-mm Luger Bullets: A Finite Element Analysis Study

    PubMed Central

    Matoso, Rodrigo Ivo; Freire, Alexandre Rodrigues; Santos, Leonardo Soriano de Mello; Daruge Junior, Eduardo; Rossi, Ana Claudia; Prado, Felippe Bevilacqua

    2014-01-01

    Firearms can cause fatal wounds, which can be identified by traces on or around the body. However, there are cases where neither the bullet nor gun is found at the crime scene. Ballistic research involving finite element models can reproduce computational biomechanical conditions, without compromising bioethics, as they involve no direct tests on animals or humans. This study aims to compare the morphologies of gunshot entrance holes caused by.40-caliber Smith & Wesson (S&W), .380-caliber, and 9×19-mm Luger bullets. A fully metal-jacketed.40 S&W projectile, a fully metal-jacketed.380 projectile, and a fully metal-jacketed 9×19-mm Luger projectile were computationally fired at the glabellar region of the finite element model from a distance of 10 cm, at perpendicular incidence. The results show different morphologies in the entrance holes produced by the three bullets, using the same skull at the same shot distance. The results and traits of the entrance holes are discussed. Finite element models allow feasible computational ballistic research, which may be useful to forensic experts when comparing and analyzing data related to gunshot wounds in the forehead. PMID:25343337

  5. Investigation of the sensitivity of MIS-sensor to thermal decomposition products of cables insulation

    NASA Astrophysics Data System (ADS)

    Filipchuk, D. V.; Litvinov, A. V.; Etrekova, M. O.; Nozdrya, D. A.

    2017-12-01

    Sensitivity of the MIS-sensor to products of thermal decomposition of insulation and jacket of the most common types of cables is investigated. It is shown that hydrogen is evolved under heating the insulation to temperatures not exceeding 250 °C. Registration of the evolved hydrogen by the MIS-sensor can be used for detection of fires at an early stage.

  6. METHOD OF JACKETING FISSIONABLE MATERIALS

    DOEpatents

    Foster, L.M.

    1959-02-01

    An improvement is presented in the jacketing of a metal body accomplished by electroplating upon that portion of the metal container to be protected from the bonding material a niatcrial such as Cr which is impermeable to the bonding material. After the bonding operation the electroplate is removed and the metal container surfuce, unimpaired, may be welded to a cap which effects a closure. Generally in such an operation the metal body is U, the metal container is Al and the bonding material is a Zn alloy.

  7. PROCESS FOR PRODUCING JACKETED BODIES

    DOEpatents

    Saller, H.A.

    1958-01-21

    A method is given for enclosing a metallic core within an outer protective jacket, such as in the production of fuel elements for neutronic reactors. The method comprises the steps of inserting the body of a first metal into an aperture in a frame of a second metal, placing a sheet of the second metal on each of opposite sides of the assembled body and frame, and bonding the sheets to the body and the frame and the body and the frame to one another.

  8. Aerogel: From Aerospace to Apparel

    NASA Technical Reports Server (NTRS)

    2001-01-01

    Aspen Systems Inc. developed an aerogel-manufacturing process solved the handling problems associated with aerogel-based insulation products. Their aerogels can now be manufactured into blankets, thin sheets, beads, and molded parts; and may be transparent, translucent, or opaque. Aspen made the material effective for window and skylight insulation, non-flammable building insulation, and inexpensive firewall insulation that will withstand fires in homes and buildings, and also assist in the prevention of forest fires. Another Aspen product is Spaceloft(TM); an inexpensive, flexible blanket that incorporates a thin layer of aerogel embedded directly into the fabric. Spaceloft, is incorporated into jackets intended for wear in extremely harsh conditions and activities, such as Antarctic expeditions.

  9. PROTECTIVELY COVERED ARTICLE AND METHOD OF MANUFACTURE

    DOEpatents

    Plott, R.F.

    1958-10-28

    A method of casting a protective jacket about a ura nium fuel element that will bond completely to the uranium without the use of stringers or supports that would ordinarily produce gaps in the cast metal coating and bond is presented. Preformed endcaps of alumlnum alloyed with 13% silicon are placed on the ends of the uranium fuel element. These caps will support the fuel element when placed in a mold. The mold is kept at a ing alloy but below that of uranium so the cast metal jacket will fuse with the endcaps forming a complete covering and bond to the fuel element, which would otherwise oxidize at the gaps or discontinuities lefi in the coating by previous casting methods.

  10. Wound ballistics of injuries caused by handguns with different types of projectiles.

    PubMed

    von See, Constantin; Stuehmer, Alexander; Gellrich, Nils-Claudius; Blum, Katrin S; Bormann, Kai-Hendrik; Rücker, Martin

    2009-07-01

    There are considerable differences in the shape and composition of military and civilian projectiles. Five different projectiles with the same kinetic energy were fired into the heads of freshly sacrificed pigs (n=30) through the submental region in the occipital direction. Computed tomography (CT) and 3D face scans of the animal skulls were obtained before and after firing. The image data sets were fused and provided the basis for a quantitative analysis of destruction patterns. As a result of the destruction of the parietal bone at the potential exit site, there were significant volume difference between the Action 4 (6.45 +/- 3.42 ml) and the Hydra-Shok projectile (12.71 +/- 2.86 ml). The partial metal-jacketed projectile showed a minor increase in volume (4.89 +/- 1.47 ml) and a partial loss of soft projectile components. Radiology showed differences between the various projectiles in fragmentation and bone and soft-tissue destruction. Although the projectiles had the same kinetic energy, there were considerable differences in injury patterns between full metal-jacketed projectiles, which are the only projectiles permitted for military use under the Geneva Conventions, and the other investigated projectiles. These injuries present a major medical challenge to both first responders and surgeons.

  11. METHOD AND MEANS FOR CLOSING TUBES BY SPINNING

    DOEpatents

    Graves, E.E.; Coonfare, R.H.

    1958-08-26

    An improved spinning tool is described for producing a fold-free closed end on an aluminum jacketing tube such as is commonly used to protect a uranium fuel element. The tool will fit the toolholder of a lathe in which the jacket is rotated. The tool has a number of working faces so that the hemispherical end- closure is formed, the folds and wrinkles are smcothed out, and the excess metal is trimmed off in one transverse cutting operation. This tool considerably speeds up the closure process, and eliminates the need for a weld seal.

  12. Effects of lightweight outdoor clothing on the prevention of hypothermia during low-intensity exercise in the cold.

    PubMed

    Burtscher, Martin; Kofler, Philipp; Gatterer, Hannes; Faulhaber, Martin; Philippe, Marc; Fischer, Kathrin; Walther, Rebekka; Herten, Anne

    2012-11-01

    To study protective effects of windbreaker jacket and pants during exercise in the cold. Randomized pilot study. Climate chamber. Nine well-trained (V[Combining Dot Above]O2max 61.7 ± 6.6 mL/min/kg) sport students (6 male and 3 female participants). Subjects started walking for 1 hour in a climate chamber (0°C ambient temperature and wind speed of 10 km/h) at 70% V[Combining Dot Above]O2max wearing gloves, a T-shirt, and shorts. Then, the walking speed was reduced to 30% V[Combining Dot Above]O2max for an additional 60 minutes or until core temperature dropped below 35.5°C. Subsequently, 3 groups of 3 participants continued walking without change of clothing or obtaining additionally a cap and a windbreaker jacket or windbreaker jacket and pants. Core and skin temperature, thermal comfort. The main findings of this study were that exercising at 70% V[Combining Dot Above]O2max in the cold was sufficient to prevent hypothermia and that during low-intensity exercise (30% V[Combining Dot Above]O2max), the combined use of a polyester cap, lightweight windbreaker jacket, and pants was necessary to increase a prehypothermic core temperature. We strongly recommend taking a cap, windbreaker jacket, and pants for the prevention of hypothermia during exhaustive walking or running in cold weather conditions.

  13. 29 CFR 1917.95 - Other protective measures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... prevent employees from obtaining safe footing for their work. (2) PFDs (life preservers, life jackets, or.... (1) Employees performing work that requires special protective clothing shall be directed by the... handlers, who are engaged in work in which they may be pulled into the water: (i) When such employees are...

  14. Thermal responses from repeated exposures to severe cold with intermittent warmer temperatures.

    PubMed

    Ozaki, H; Enomoto-Koshimizu, H; Tochihara, Y; Nakamura, K

    1998-09-01

    This study was conducted to evaluate physiological reaction and manual performance during exposure to warm (30 degrees C) and cool (10 degrees C) environments after exposure to very low temperatures (-25 degrees C). Furthermore, this experiment was conducted to study whether it is desirable to remove cold-protective jackets in warmer rooms after severe cold exposure. Eight male students remained in an extremely cold room for 20 min, after which they transferred into either the warm room or the cool room for 20 min. This pattern was repeated three times, and the total cold exposure time was 60 min. In the warm and cool rooms, the subjects either removed their cold-protective jackets (Condition A), or wore them continuously (Condition B). Rectal temperature, skin temperatures, manual performance, blood pressure, thermal, comfort and pain sensations were measured during the experiment. The effects of severe cold on almost all measurements in the cool (10 degrees C) environment were greater than those in the warm (30 degrees C) environment under both clothing conditions. The effects of severe cold on all measurements under Condition A except rectal temperature and toe skin temperature were significantly greater than those under Condition B in the cool environment but, not at all differences between Condition A and Condition B in the warm environments were significant. It was recognized that to remove cold-protective jackets in the cool room (10 degrees C) after severe cold exposure promoted the effects of severe cold. When rewarming in the warm resting room (30 degrees C), the physiological and psychological responses and manual performance were not influenced by the presence or absence of cold-protective clothing. These results suggest that it is necessary for workers to make sure to rewarm in the warm room outside of the cold storage and continue to wear cold-protective clothing in the cool room.

  15. The four-poster halo vest for protection of a microvascular free-tissue transfer reconstruction of the scalp.

    PubMed

    Wooden, W A; Curtsinger, L J; Jones, N F

    1995-01-01

    Use of a four-poster halo and corset jacket provides complete protection, access, and mobility for patients undergoing free-flap scalp reconstruction. This technique was used in a patient who required a total scalp reconstruction with a compound latissimus/serratus muscle free flap with good success. The case and technique are presented for review.

  16. Determinants of personal protective equipment (PPE) use in UK motorcyclists: exploratory research applying an extended theory of planned behaviour.

    PubMed

    Norris, Emma; Myers, Lynn

    2013-11-01

    Despite evident protective value of motorcycle personal protective equipment (PPE), no research has assessed considerations behind its uptake in UK riders. A cross-sectional online questionnaire design was employed, with riders (n=268) recruited from online motorcycle forums. Principal component analysis found four PPE behavioural outcomes. Theoretical factors of intentions, attitudes, injunctive and descriptive subjective norms, risk perceptions, anticipated regret, benefits and habit were also identified for further analysis. High motorcycle jacket, trousers and boots wear, middling high-visibility wear and low non-Personal Protective Equipment wear were found. Greater intentions, anticipated regret and perceived benefits were significantly associated with increased motorcycle jacket, trousers and boots wear, with habit presence and scooter use significantly associated with increased high-visibility wear. Lower intentions, anticipated regret and risk perceptions, being female, not holding a car licence and urban riding were significantly associated with increased non-PPE wear. A need for freedom of choice and mixed attitudes towards PPE use were evident in additional comments. PPE determinants in this sample provide a preliminary basis for future uptake interventions. Larger scale and qualitative research is needed to further investigate relevant constructs. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. 46 CFR 180.75 - Life jacket lights.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Life jacket lights. 180.75 Section 180.75 Shipping COAST...) LIFESAVING EQUIPMENT AND ARRANGEMENTS Ring Life Buoys and Life Jackets § 180.75 Life jacket lights. (a) Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket...

  18. 46 CFR 180.75 - Life jacket lights.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Life jacket lights. 180.75 Section 180.75 Shipping COAST...) LIFESAVING EQUIPMENT AND ARRANGEMENTS Ring Life Buoys and Life Jackets § 180.75 Life jacket lights. (a) Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket...

  19. METHOD OF JACKETING A FISSIONABLE BODY

    DOEpatents

    Creutz, E.C.

    1960-02-16

    A method for jacketing fuel elements is described. A fissionablc body ts fitted into a steel jacket, and a steel rimmed closure disk is inserted into the open end of the jacket. The jacket is then drawn through a die, aind the rim of the disk is welded to the jacket to form an impervious seal.

  20. Health-hazard evaluation report HETA-91-161-2225, Denver Police Department, Denver, Colorado

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, S.A.; McCammon, C.S.

    1992-05-01

    In response to a request from the Denver Police Department (SIC-9221) in Denver, Colorado, an investigation was made into lead (7439921) exposures during the use of different ammunition on the firing range. Ventilation rates were measured and personal breathing zone air samples were collected for ten officers during the firing of .45 caliber pistols. Nonlead primers were not yet available for .45 caliber ammunition. Air lead exposure ranged from 1.0 to 16 micrograms/cubic meter (microg/cu m). A slight improvement was noted in ventilation since an earlier NIOSH study had been performed at this site. The improvement resulted from the removalmore » of a 3 foot high partition along the floor on the firing line. There was still, however, turbulent air flow across the entire firing line and backflow in some of the shooting booths. The author concludes that there was no health hazard from lead overexposure at this site at this time, but recommends use of jacketed bullets, nonlead primers, and administrative controls to minimize lead exposures.« less

  1. 46 CFR 180.71 - Life jackets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Life jackets. 180.71 Section 180.71 Shipping COAST GUARD... EQUIPMENT AND ARRANGEMENTS Ring Life Buoys and Life Jackets § 180.71 Life jackets. (a) An adult life jacket... life jackets equal to at least 10% of the number of persons permitted on board must be provided, or...

  2. 46 CFR 180.71 - Life jackets.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Life jackets. 180.71 Section 180.71 Shipping COAST GUARD... EQUIPMENT AND ARRANGEMENTS Ring Life Buoys and Life Jackets § 180.71 Life jackets. (a) An adult life jacket... life jackets equal to at least 10% of the number of persons permitted on board must be provided, or...

  3. 46 CFR 117.75 - Life jacket lights.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Life jacket lights. 117.75 Section 117.75 Shipping COAST... Ring Life Buoys and Life Jackets § 117.75 Life jacket lights. (a) Each life jacket carried on a vessel on an oceans, coastwise, or Great Lakes route, must have a life jacket light approved in accordance...

  4. 46 CFR 117.75 - Life jacket lights.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Life jacket lights. 117.75 Section 117.75 Shipping COAST... Ring Life Buoys and Life Jackets § 117.75 Life jacket lights. (a) Each life jacket carried on a vessel on an oceans, coastwise, or Great Lakes route, must have a life jacket light approved in accordance...

  5. 46 CFR 180.71 - Life jackets.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Life jackets. 180.71 Section 180.71 Shipping COAST GUARD... EQUIPMENT AND ARRANGEMENTS Ring Life Buoys and Life Jackets § 180.71 Life jackets. (a) An adult life jacket... life jackets equal to at least 10% of the number of persons permitted on board must be provided, or...

  6. 46 CFR 180.71 - Life jackets.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Life jackets. 180.71 Section 180.71 Shipping COAST GUARD... EQUIPMENT AND ARRANGEMENTS Ring Life Buoys and Life Jackets § 180.71 Life jackets. (a) An adult life jacket... life jackets equal to at least 10% of the number of persons permitted on board must be provided, or...

  7. 46 CFR 180.71 - Life jackets.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Life jackets. 180.71 Section 180.71 Shipping COAST GUARD... EQUIPMENT AND ARRANGEMENTS Ring Life Buoys and Life Jackets § 180.71 Life jackets. (a) An adult life jacket... life jackets equal to at least 10% of the number of persons permitted on board must be provided, or...

  8. 46 CFR 117.75 - Life jacket lights.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Life jacket lights. 117.75 Section 117.75 Shipping COAST... Ring Life Buoys and Life Jackets § 117.75 Life jacket lights. (a) Each life jacket carried on a vessel on an oceans, coastwise, or Great Lakes route, must have a life jacket light approved in accordance...

  9. 46 CFR 117.75 - Life jacket lights.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Life jacket lights. 117.75 Section 117.75 Shipping COAST... Ring Life Buoys and Life Jackets § 117.75 Life jacket lights. (a) Each life jacket carried on a vessel on an oceans, coastwise, or Great Lakes route, must have a life jacket light approved in accordance...

  10. 46 CFR 117.75 - Life jacket lights.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Life jacket lights. 117.75 Section 117.75 Shipping COAST... Ring Life Buoys and Life Jackets § 117.75 Life jacket lights. (a) Each life jacket carried on a vessel on an oceans, coastwise, or Great Lakes route, must have a life jacket light approved in accordance...

  11. Double-ended metal halide arc discharge lamp with electrically isolated containment shroud

    NASA Technical Reports Server (NTRS)

    Muzeroll, Martin M. (Inventor)

    1994-01-01

    A double-ended arc discharge lamp includes a sealed, light-transmissive outer jacket, a light-transmissive shroud mounted within the outer jacket and directly supported by the outer jacket, and an arc discharge tube mounted within the shroud. The arc tube is typically a metal halide arc discharge tube. In a preferred embodiment, the shroud includes an outwardly flared portion at each end. The outwardly flared portions space the shroud from the outer jacket and support the shroud within the outer jacket. The outwardly flared portions of the shroud can be affixed to the outer jacket by fusing. The outer jacket can be provided with inwardly extending dimples for locating the shroud with respect to the outer jacket. In another embodiment, the outer jacket includes reduced diameter portions near each end which are attached to the shroud.

  12. 46 CFR 117.71 - Life jackets.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Life jackets. 117.71 Section 117.71 Shipping COAST GUARD... OVERNIGHT ACCOMMODATIONS FOR MORE THAN 49 PASSENGERS LIFESAVING EQUIPMENT AND ARRANGEMENTS Ring Life Buoys and Life Jackets § 117.71 Life jackets. (a) An adult life jacket must be provided for each person...

  13. 46 CFR 117.78 - Stowage of life jackets.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Stowage of life jackets. 117.78 Section 117.78 Shipping... Ring Life Buoys and Life Jackets § 117.78 Stowage of life jackets. (a) General. Unless otherwise stated in this section, life jackets must be stored in convenient places distributed throughout...

  14. 46 CFR 117.78 - Stowage of life jackets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Stowage of life jackets. 117.78 Section 117.78 Shipping... Ring Life Buoys and Life Jackets § 117.78 Stowage of life jackets. (a) General. Unless otherwise stated in this section, life jackets must be stored in convenient places distributed throughout...

  15. 46 CFR 117.71 - Life jackets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Life jackets. 117.71 Section 117.71 Shipping COAST GUARD... OVERNIGHT ACCOMMODATIONS FOR MORE THAN 49 PASSENGERS LIFESAVING EQUIPMENT AND ARRANGEMENTS Ring Life Buoys and Life Jackets § 117.71 Life jackets. (a) An adult life jacket must be provided for each person...

  16. 46 CFR 117.78 - Stowage of life jackets.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Stowage of life jackets. 117.78 Section 117.78 Shipping... Ring Life Buoys and Life Jackets § 117.78 Stowage of life jackets. (a) General. Unless otherwise stated in this section, life jackets must be stored in convenient places distributed throughout...

  17. 46 CFR 117.78 - Stowage of life jackets.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Stowage of life jackets. 117.78 Section 117.78 Shipping... Ring Life Buoys and Life Jackets § 117.78 Stowage of life jackets. (a) General. Unless otherwise stated in this section, life jackets must be stored in convenient places distributed throughout...

  18. 46 CFR 117.71 - Life jackets.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Life jackets. 117.71 Section 117.71 Shipping COAST GUARD... OVERNIGHT ACCOMMODATIONS FOR MORE THAN 49 PASSENGERS LIFESAVING EQUIPMENT AND ARRANGEMENTS Ring Life Buoys and Life Jackets § 117.71 Life jackets. (a) An adult life jacket must be provided for each person...

  19. 46 CFR 117.71 - Life jackets.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Life jackets. 117.71 Section 117.71 Shipping COAST GUARD... OVERNIGHT ACCOMMODATIONS FOR MORE THAN 49 PASSENGERS LIFESAVING EQUIPMENT AND ARRANGEMENTS Ring Life Buoys and Life Jackets § 117.71 Life jackets. (a) An adult life jacket must be provided for each person...

  20. 46 CFR 117.78 - Stowage of life jackets.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Stowage of life jackets. 117.78 Section 117.78 Shipping... Ring Life Buoys and Life Jackets § 117.78 Stowage of life jackets. (a) General. Unless otherwise stated in this section, life jackets must be stored in convenient places distributed throughout...

  1. 46 CFR 117.71 - Life jackets.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Life jackets. 117.71 Section 117.71 Shipping COAST GUARD... OVERNIGHT ACCOMMODATIONS FOR MORE THAN 49 PASSENGERS LIFESAVING EQUIPMENT AND ARRANGEMENTS Ring Life Buoys and Life Jackets § 117.71 Life jackets. (a) An adult life jacket must be provided for each person...

  2. Variable pressure thermal insulating jacket

    DOEpatents

    Nelson, Paul A.; Malecha, Richard F.; Chilenskas, Albert A.

    1994-01-01

    A device for controlled insulation of a thermal device. The device includes a thermal jacket with a closed volume able to be evacuated to form an insulating jacket around the thermal source. A getter material is in communcation with the closed volume of the thermal jacket. The getter material can absorb and desorb a control gas to control gas pressure in the volume of the thermal jacket to control thermal conductivity in the thermal jacket.

  3. Discrimination of bullet types using analysis of lead isotopes deposited in gunshot entry wounds.

    PubMed

    Wunnapuk, Klintean; Minami, Takeshi; Durongkadech, Piya; Tohno, Setsuko; Ruangyuttikarn, Werawan; Moriwake, Yumi; Vichairat, Karnda; Sribanditmongkol, Pongruk; Tohno, Yoshiyuki

    2009-01-01

    In order to discriminate bullet types used in firearms, of which the victims died, the authors investigated lead isotope ratios in gunshot entry wounds from nine lead (unjacketed) bullets, 15 semi-jacketed bullets, and 14 full-jacketed bullets by inductively coupled plasma-mass spectrometry. It was found that the lead isotope ratio of 207/206 in gunshot entry wounds was the highest with lead bullets, and it decreased in order from full-jacketed to semi-jacketed bullets. Lead isotope ratios of 208/206 or 208/207 to 207/206 at the gunshot entry wound were able to discriminate semi-jacketed bullets from lead and full-jacketed ones, but it was difficult to discriminate between lead and full-jacketed bullets. However, a combination of element and lead isotope ratio analyses in gunshot entry wounds enabled discrimination between lead, semi-jacketed, and full-jacketed bullets.

  4. Variable pressure thermal insulating jacket

    DOEpatents

    Nelson, P.A.; Malecha, R.F.; Chilenskas, A.A.

    1994-09-20

    A device for controlled insulation of a thermal device is disclosed. The device includes a thermal jacket with a closed volume able to be evacuated to form an insulating jacket around the thermal source. A getter material is in communication with the closed volume of the thermal jacket. The getter material can absorb and desorb a control gas to control gas pressure in the volume of the thermal jacket to control thermal conductivity in the thermal jacket. 10 figs.

  5. 46 CFR 180.78 - Stowage of life jackets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Stowage of life jackets. 180.78 Section 180.78 Shipping...) LIFESAVING EQUIPMENT AND ARRANGEMENTS Ring Life Buoys and Life Jackets § 180.78 Stowage of life jackets. (a) General. Unless otherwise stated in this section, life jackets must be stored in convenient places...

  6. 46 CFR 180.78 - Stowage of life jackets.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Stowage of life jackets. 180.78 Section 180.78 Shipping...) LIFESAVING EQUIPMENT AND ARRANGEMENTS Ring Life Buoys and Life Jackets § 180.78 Stowage of life jackets. (a) General. Unless otherwise stated in this section, life jackets must be stored in convenient places...

  7. 46 CFR 180.78 - Stowage of life jackets.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Stowage of life jackets. 180.78 Section 180.78 Shipping...) LIFESAVING EQUIPMENT AND ARRANGEMENTS Ring Life Buoys and Life Jackets § 180.78 Stowage of life jackets. (a) General. Unless otherwise stated in this section, life jackets must be stored in convenient places...

  8. 46 CFR 180.78 - Stowage of life jackets.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Stowage of life jackets. 180.78 Section 180.78 Shipping...) LIFESAVING EQUIPMENT AND ARRANGEMENTS Ring Life Buoys and Life Jackets § 180.78 Stowage of life jackets. (a) General. Unless otherwise stated in this section, life jackets must be stored in convenient places...

  9. 46 CFR 180.78 - Stowage of life jackets.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Stowage of life jackets. 180.78 Section 180.78 Shipping...) LIFESAVING EQUIPMENT AND ARRANGEMENTS Ring Life Buoys and Life Jackets § 180.78 Stowage of life jackets. (a) General. Unless otherwise stated in this section, life jackets must be stored in convenient places...

  10. CUTTING AND WEDGING JACKET REMOVER

    DOEpatents

    Freedman, M.; Raynor, S.

    1959-04-01

    A tool is presented for stripping cladded jackets from fissionable fuel elements. The tool is a tube which fits closely around the jacket and which has two cutting edges at opposite sides of one end. These cutting edges are adjusted to penetrate only the jacket so that by moving the edges downward the jacket is cut into two pieces.

  11. CORROSION RESISTANT JACKETED METAL BODY

    DOEpatents

    Brugmann, E.W.

    1958-08-26

    Reactor faul elements of the elongated cylindrical type which are jacketed in a corrosion resistant material are described. Each feel element is comprised of a plurality of jacketed cylinders of fissionable material in end to end abutting relationship, the jackets being welded together at their adjoining ends to retain the individual segments together and seat the interior of the jackets.

  12. Wearable system-on-a-chip radiometer for remote temperature sensing and its application to the safeguard of emergency operators.

    PubMed

    Fonte, A; Alimenti, F; Zito, D; Neri, B; De Rossi, D; Lanatà, A; Tognetti, A

    2007-01-01

    The remote sensing and the detection of events that may represent a danger for human beings have become more and more important thanks to the latest advances of the technology. A microwave radiometer is a sensor capable to detect a fire or an abnormal increase of the internal temperature of the human body (hyperthermia), or an onset of a cancer, or even meteorological phenomena (forest fires, pollution release, ice formation on road pavement). In this paper, the overview of a wearable low-cost low-power system-on-a-chip (SoaC) 13 GHz passive microwave radiometer in CMOS 90 nm technology is presented. In particular, we focused on its application to the fire detection for civil safeguard. In detail, this sensor has been thought to be inserted into the fireman jacket in order to help the fireman in the detection of a hidden fire behind a door or a wall. The simulation results obtained by Ptolemy system simulation have confirmed the feasibility of such a SoaC microwave radiometer in a low-cost standard silicon technology for temperature remote sensing and, in particular, for its application to the safeguard of emergency operators.

  13. METHOD OF TESTING FOR LEAKS

    DOEpatents

    Creutz, E.C.; McAdams, Wm.A.; Foss, M.H.

    1958-07-22

    A method is described for detecting minute holes In fuel element jackets. The method comprises submerging the jacketed body in an atmosphere of a radioactive gas under pressure, the radioactive emanations from said gas being sufficientiy penetratIng to penetrate the jacket of the jacketed body. After the jacketed body is removed from the radtoactive gas atmosphere, it is exannined for the presence of emanations from radioactive gas which entered the jacketed body through the minute holes. In this manner, the detectton of radioactive emanations is a positive indication that the fuel element is not perfectly sealed.

  14. Modeling of fire smoke movement in multizone garments building using two open source platforms

    NASA Astrophysics Data System (ADS)

    Khandoker, Md. Arifur Rahman; Galib, Musanna; Islam, Adnan; Rahman, Md. Ashiqur

    2017-06-01

    Casualty of garment factory workers from factory fire in Bangladesh is a recurring tragedy. Smoke, which is more fatal than fire itself, often propagates through different pathways from lower to upper floors during building fire. Among the toxic gases produced from a building fire, carbon monoxide (CO) can be deadly, even in small amounts. This paper models the propagation and transportation of fire induced smoke (CO) that resulted from the burning of synthetic polyester fibers using two open source platforms, CONTAM and Fire Dynamics Simulator (FDS). Smoke migration in a generic multistoried garment factory building in Bangladesh is modeled using CONTAM where each floor is compartmentalized by different zones. The elevator and stairway shafts are modeled by phantom zones to simulate contaminant (CO) transport from one floor to upper floors. FDS analysis involves burning of two different stacks of polyester jacket of six feet height and with a maximum heat release rate per unit area of 1500kw/m2 over a storage area 50m2 and 150m2, respectively. The resulting CO generation and removal rates from FDS are used in CONTAM to predict fire-borne CO propagation in different zones of the garment building. Findings of the study exhibit that the contaminant flow rate is a strong function of the position of building geometry, location of initiation of fire, amount of burnt material, presence of AHU and contaminant generation and removal rate of CO from the source location etc. The transport of fire-smoke in the building Hallways, stairways and lifts are also investigated in detail to examine the safe egress of the occupants in case of fire.

  15. Method of preventing leakage of a fluid along and through an insulating jacket of a thermocouple

    DOEpatents

    Thermos, Anthony Constantine; Rahal, Fadi Elias

    2002-01-01

    A thermocouple assembly includes a thermocouple; a plurality of lead wires extending from the thermocouple; an insulating jacket extending along and enclosing the plurality of leads; and at least one internally sealed area within the insulating jacket to prevent fluid leakage along and within the insulating jacket. The invention also provides a method of preventing leakage of a fluid along and through an insulating jacket of a thermocouple including the steps of a) attaching a plurality of lead wires to a thermocouple; b) adding a heat sensitive pseudo-wire to extend along the plurality of lead wires; c) enclosing the lead wires and pseudo-wire inside an insulating jacket; d) locally heating axially spaced portions of the insulating jacket to a temperature which melts the pseudo-wire and fuses it with an interior surface of the jacket.

  16. 30 CFR 18.36 - Cables between machine components.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... mechanical damage by position, flame-resistant hose conduit, metal tubing, or troughs (flexible or threaded rigid metal conduit will not be acceptable), (3) isolated from hydraulic lines, and (4) protected from... heavy jackets, the sizes of which are stated in Table 6 of Appendix I. Cables (cords) provided with hose...

  17. 30 CFR 18.36 - Cables between machine components.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... mechanical damage by position, flame-resistant hose conduit, metal tubing, or troughs (flexible or threaded rigid metal conduit will not be acceptable), (3) isolated from hydraulic lines, and (4) protected from... heavy jackets, the sizes of which are stated in Table 6 of Appendix I. Cables (cords) provided with hose...

  18. 30 CFR 18.36 - Cables between machine components.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... mechanical damage by position, flame-resistant hose conduit, metal tubing, or troughs (flexible or threaded rigid metal conduit will not be acceptable), (3) isolated from hydraulic lines, and (4) protected from... heavy jackets, the sizes of which are stated in Table 6 of Appendix I. Cables (cords) provided with hose...

  19. Evaluation of anodes for galvanic cathodic prevention of steel corrosion in prestressed concrete piles in marine environments in Virginia.

    DOT National Transportation Integrated Search

    1999-07-01

    Many of the major highway crossings over coastal waters in the Hampton area of Virginia are supported by prestressed concrete piles, some of which are showing signs of reinforcement corrosion. Grout jacketing alone is an inadequate protection against...

  20. 49 CFR 179.16 - Tank-head puncture-resistance systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... CARS General Design Requirements § 179.16 Tank-head puncture-resistance systems. (a) Performance...; and (3) The impacted tank car is pressurized to at least 6.9 Bar (100 psig). (b) Verification by... design and test requirements of the full-head protection (shields) or full tank-head jackets must meet...

  1. 29 CFR 1926.106 - Working over or near water.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... drowning exists, shall be provided with U.S. Coast Guard-approved life jacket or buoyant work vests. (b) Prior to and after each use, the buoyant work vests or life preservers shall be inspected for defects... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Personal Protective and Life Saving Equipment...

  2. Regeneratively Cooled Porous Media Jacket

    NASA Technical Reports Server (NTRS)

    Mungas, Greg (Inventor); Fisher, David J. (Inventor); London, Adam Pollok (Inventor); Fryer, Jack Merrill (Inventor)

    2013-01-01

    The fluid and heat transfer theory for regenerative cooling of a rocket combustion chamber with a porous media coolant jacket is presented. This model is used to design a regeneratively cooled rocket or other high temperature engine cooling jacket. Cooling jackets comprising impermeable inner and outer walls, and porous media channels are disclosed. Also disclosed are porous media coolant jackets with additional structures designed to transfer heat directly from the inner wall to the outer wall, and structures designed to direct movement of the coolant fluid from the inner wall to the outer wall. Methods of making such jackets are also disclosed.

  3. 14 CFR 23.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Combustion heater fire protection. 23.859... Construction Fire Protection § 23.859 Combustion heater fire protection. (a) Combustion heater fire regions. The following combustion heater fire regions must be protected from fire in accordance with the...

  4. 14 CFR 23.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Combustion heater fire protection. 23.859... Construction Fire Protection § 23.859 Combustion heater fire protection. (a) Combustion heater fire regions. The following combustion heater fire regions must be protected from fire in accordance with the...

  5. 14 CFR 23.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Combustion heater fire protection. 23.859... Construction Fire Protection § 23.859 Combustion heater fire protection. (a) Combustion heater fire regions. The following combustion heater fire regions must be protected from fire in accordance with the...

  6. 14 CFR 23.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Combustion heater fire protection. 23.859... Construction Fire Protection § 23.859 Combustion heater fire protection. (a) Combustion heater fire regions. The following combustion heater fire regions must be protected from fire in accordance with the...

  7. 14 CFR 23.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Combustion heater fire protection. 23.859... Construction Fire Protection § 23.859 Combustion heater fire protection. (a) Combustion heater fire regions. The following combustion heater fire regions must be protected from fire in accordance with the...

  8. BARRIERS TO LIFE JACKET USE AMONG ADULT RECREATIONAL BOATERS

    PubMed Central

    Quistberg, D. Alex; Quan, Linda; Ebel, Beth E.; Bennett, Elizabeth E.; Mueller, Beth A.

    2015-01-01

    Objective To identify barriers to life jacket use. Design Cross-sectional survey. Setting Nine public boat ramps in western Washington State, USA, August-November, 2008. Participants 675 adult boaters (>18 years) on motor boats <26 feet long. Main outcome Low or no life jacket use (0–50% of time) versus high life jacket use (51–100% of time). Results Low/no life jacket use (0%–50% of time) was associated with longer boat length (per foot, risk ratio [RR] 1.03, 95% confidence interval [CI] 1.02–1.05), alcohol use (RR 1.11, 95% CI 1.01–1.20), perception of life jackets as “uncomfortable” (RR 1.29, 95%CI 1.09–1.52), perceived greater level of swimming ability (RR 1.25, 95% CI 1.03–1.53 for “expert swimmer”), and possibly with lack of confidence that a life jacket may save one from drowning (RR 1.13, 95%CI 0.96–1.32). Low life jacket use was less likely when a child was onboard (RR 0.88, 95% CI 0.79–0.99), or if the respondent had taken a boating safety class (RR 0.94, 95% CI 0.87–1.01). Conclusions Life jacket use may increase with more comfortable devices, such as inflatable life jackets, and with increased awareness of their efficacy in preventing drowning. Boater education classes may be associated with increased life jacket use among adults. PMID:24686261

  9. Thermocouple assembly

    DOEpatents

    Thermos, Anthony Constantine; Rahal, Fadi Elias

    2002-01-01

    A thermocouple assembly includes a thermocouple; a plurality of lead wires extending from the thermocouple; an insulating jacket extending along and enclosing the plurality of leads; and at least one internally sealed area within the insulating jacket to prevent fluid leakage along and within the insulating jacket. The invention also provides a method of preventing leakage of a fluid along and through an insulating jacket of a thermocouple including the steps of a) attaching a plurality of lead wires to a thermocouple; b) adding a heat sensitive pseudo-wire to extend along the plurality of lead wires; c) enclosing the lead wires and pseudo-wire inside an insulating jacket; d) locally heating axially spaced portions of the insulating jacket to a temperature which melts the pseudo-wire and fuses it with an interior surface of the jacket.

  10. Plating Patches On Heat-Exchanger Jackets

    NASA Technical Reports Server (NTRS)

    Loureiro, Henry; Kubik, Frank

    1989-01-01

    Permanent repairs made without welding. Technique used to repair nickel-alloy nozzle jacket of Space Shuttle main engine. Applicable to other metal heat-exchanger jackets with similar configurations. Does not require welding, brazing, soldering, or other operations involving high temperatures and consequent damage to surrounding areas. Portion of jacket around damaged area removed by grinding and polishing out to edges adjacent to tube/jacket braze bonds. Spaces between tubes filled with wax preventing contamination of spaces during subsequent plating.

  11. 46 CFR 185.516 - Life jacket placards.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Life jacket placards. 185.516 Section 185.516 Shipping...) OPERATIONS Preparations for Emergencies § 185.516 Life jacket placards. (a) Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places...

  12. 46 CFR 185.508 - Wearing of life jackets.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Wearing of life jackets. 185.508 Section 185.508... TONS) OPERATIONS Preparations for Emergencies § 185.508 Wearing of life jackets. (a) The master of a vessel shall require passengers to don life jackets when possible hazardous conditions exist, including...

  13. 46 CFR 122.516 - Life jacket placards.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Life jacket placards. 122.516 Section 122.516 Shipping... Emergencies § 122.516 Life jacket placards. (a) Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible...

  14. 46 CFR 185.508 - Wearing of life jackets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Wearing of life jackets. 185.508 Section 185.508... TONS) OPERATIONS Preparations for Emergencies § 185.508 Wearing of life jackets. (a) The master of a vessel shall require passengers to don life jackets when possible hazardous conditions exist, including...

  15. 46 CFR 185.516 - Life jacket placards.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Life jacket placards. 185.516 Section 185.516 Shipping...) OPERATIONS Preparations for Emergencies § 185.516 Life jacket placards. (a) Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places...

  16. 46 CFR 122.516 - Life jacket placards.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Life jacket placards. 122.516 Section 122.516 Shipping... Emergencies § 122.516 Life jacket placards. (a) Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible...

  17. 46 CFR 185.516 - Life jacket placards.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Life jacket placards. 185.516 Section 185.516 Shipping...) OPERATIONS Preparations for Emergencies § 185.516 Life jacket placards. (a) Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places...

  18. 46 CFR 122.516 - Life jacket placards.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Life jacket placards. 122.516 Section 122.516 Shipping... Emergencies § 122.516 Life jacket placards. (a) Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible...

  19. 46 CFR 185.516 - Life jacket placards.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Life jacket placards. 185.516 Section 185.516 Shipping...) OPERATIONS Preparations for Emergencies § 185.516 Life jacket placards. (a) Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places...

  20. 46 CFR 185.508 - Wearing of life jackets.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Wearing of life jackets. 185.508 Section 185.508... TONS) OPERATIONS Preparations for Emergencies § 185.508 Wearing of life jackets. (a) The master of a vessel shall require passengers to don life jackets when possible hazardous conditions exist, including...

  1. 46 CFR 185.516 - Life jacket placards.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Life jacket placards. 185.516 Section 185.516 Shipping...) OPERATIONS Preparations for Emergencies § 185.516 Life jacket placards. (a) Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places...

  2. 46 CFR 185.508 - Wearing of life jackets.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Wearing of life jackets. 185.508 Section 185.508... TONS) OPERATIONS Preparations for Emergencies § 185.508 Wearing of life jackets. (a) The master of a vessel shall require passengers to don life jackets when possible hazardous conditions exist, including...

  3. 46 CFR 122.516 - Life jacket placards.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Life jacket placards. 122.516 Section 122.516 Shipping... Emergencies § 122.516 Life jacket placards. (a) Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible...

  4. 46 CFR 185.508 - Wearing of life jackets.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Wearing of life jackets. 185.508 Section 185.508... TONS) OPERATIONS Preparations for Emergencies § 185.508 Wearing of life jackets. (a) The master of a vessel shall require passengers to don life jackets when possible hazardous conditions exist, including...

  5. 46 CFR 122.516 - Life jacket placards.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Life jacket placards. 122.516 Section 122.516 Shipping... Emergencies § 122.516 Life jacket placards. (a) Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible...

  6. 30 CFR 250.905 - How do I get approval for the installation, modification, or repair of my platform?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF...., cathodic protection systems; jacket design; pile foundations; drilling, production, and pipeline risers and... design or analysis of the platform. Examples of relevant data include information on waves, wind, current...

  7. Ported jacket for use in deformation measurement apparatus

    DOEpatents

    Wagner, L.A.; Senseny, P.E.; Mellegard, K.D.; Olsberg, S.B.

    1990-03-06

    A device for allowing deformation measurement of a jacketed specimen when the specimen is loaded includes an elastomeric specimen container or jacket surrounding a specimen while the specimen is being loaded by a test apparatus. The specimen jacket wall is compressible, and the wall follows and allows deformation of the specimen. The jacket wall of compressible material is provided with at least one opening and a thin layer or shim of substantially non-compressible (metal) material which covers and seals this opening. An extensometer is then positioned with its specimen engaging contact members engaging the substantially non-compressible material to measure the deformation of the specimen when the specimen is loaded, without compressibility effects of the jacket. 9 figs.

  8. Method and apparatus for packaging optical fiber sensors for harsh environments

    DOEpatents

    Pickrell, Gary; Duan, Yuhong; Wang, Anbo

    2005-08-09

    A package for an optical fiber sensor having a metal jacket surrounding the sensor, and heat-shrink tubing surrounding the metal jacket. The metal jacket is made of a low melting point metal (e.g. lead, tin). The sensor can be disposed in a rigid tube (e.g. stainless steel or glass) that is surrounded by the metal jacket. The metal jacket provides a hermetic, or nearly hermetic seal for the sensor. The package is made by melting the metal jacket and heating the heat shrink tubing at the same time. As the heat-shrink tubing shrinks, it presses the low melting point metal against the sensor, and squeezes out the excess metal.

  9. Factors Controlling Vegetation Fires in Protected and Non-Protected Areas of Myanmar

    PubMed Central

    Biswas, Sumalika; Vadrevu, Krishna Prasad; Lwin, Zin Mar; Lasko, Kristofer; Justice, Christopher O.

    2015-01-01

    Fire is an important disturbance agent in Myanmar impacting several ecosystems. In this study, we quantify the factors impacting vegetation fires in protected and non-protected areas of Myanmar. Satellite datasets in conjunction with biophysical and anthropogenic factors were used in a spatial framework to map the causative factors of fires. Specifically, we used the frequency ratio method to assess the contribution of each causative factor to overall fire susceptibility at a 1km scale. Results suggested the mean fire density in non-protected areas was two times higher than the protected areas. Fire-land cover partition analysis suggested dominant fire occurrences in the savannas (protected areas) and woody savannas (non-protected areas). The five major fire causative factors in protected areas in descending order include population density, land cover, tree cover percent, travel time from nearest city and temperature. In contrast, the causative factors in non-protected areas were population density, tree cover percent, travel time from nearest city, temperature and elevation. The fire susceptibility analysis showed distinct spatial patterns with central Myanmar as a hot spot of vegetation fires. Results from propensity score matching suggested that forests within protected areas have 11% less fires than non-protected areas. Overall, our results identify important causative factors of fire useful to address broad scale fire risk concerns at a landscape scale in Myanmar. PMID:25909632

  10. Factors controlling vegetation fires in protected and non-protected areas of myanmar.

    PubMed

    Biswas, Sumalika; Vadrevu, Krishna Prasad; Lwin, Zin Mar; Lasko, Kristofer; Justice, Christopher O

    2015-01-01

    Fire is an important disturbance agent in Myanmar impacting several ecosystems. In this study, we quantify the factors impacting vegetation fires in protected and non-protected areas of Myanmar. Satellite datasets in conjunction with biophysical and anthropogenic factors were used in a spatial framework to map the causative factors of fires. Specifically, we used the frequency ratio method to assess the contribution of each causative factor to overall fire susceptibility at a 1km scale. Results suggested the mean fire density in non-protected areas was two times higher than the protected areas. Fire-land cover partition analysis suggested dominant fire occurrences in the savannas (protected areas) and woody savannas (non-protected areas). The five major fire causative factors in protected areas in descending order include population density, land cover, tree cover percent, travel time from nearest city and temperature. In contrast, the causative factors in non-protected areas were population density, tree cover percent, travel time from nearest city, temperature and elevation. The fire susceptibility analysis showed distinct spatial patterns with central Myanmar as a hot spot of vegetation fires. Results from propensity score matching suggested that forests within protected areas have 11% less fires than non-protected areas. Overall, our results identify important causative factors of fire useful to address broad scale fire risk concerns at a landscape scale in Myanmar.

  11. 30 CFR 56.15020 - Life jackets and belts.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Life jackets and belts. 56.15020 Section 56.15020 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... § 56.15020 Life jackets and belts. Life jackets or belts shall be worn where there is danger from...

  12. 46 CFR 122.508 - Wearing of life jackets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Wearing of life jackets. 122.508 Section 122.508... Preparations for Emergencies § 122.508 Wearing of life jackets. (a) The master of a vessel shall require passengers to don life jackets when possible hazardous conditions exist, including, but not limited to: (1...

  13. 46 CFR 122.508 - Wearing of life jackets.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Wearing of life jackets. 122.508 Section 122.508... Preparations for Emergencies § 122.508 Wearing of life jackets. (a) The master of a vessel shall require passengers to don life jackets when possible hazardous conditions exist, including, but not limited to: (1...

  14. 30 CFR 56.15020 - Life jackets and belts.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Life jackets and belts. 56.15020 Section 56.15020 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... § 56.15020 Life jackets and belts. Life jackets or belts shall be worn where there is danger from...

  15. 46 CFR 122.508 - Wearing of life jackets.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Wearing of life jackets. 122.508 Section 122.508... Preparations for Emergencies § 122.508 Wearing of life jackets. (a) The master of a vessel shall require passengers to don life jackets when possible hazardous conditions exist, including, but not limited to: (1...

  16. 30 CFR 56.15020 - Life jackets and belts.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Life jackets and belts. 56.15020 Section 56.15020 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... § 56.15020 Life jackets and belts. Life jackets or belts shall be worn where there is danger from...

  17. 30 CFR 56.15020 - Life jackets and belts.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Life jackets and belts. 56.15020 Section 56.15020 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... § 56.15020 Life jackets and belts. Life jackets or belts shall be worn where there is danger from...

  18. 46 CFR 122.508 - Wearing of life jackets.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Wearing of life jackets. 122.508 Section 122.508... Preparations for Emergencies § 122.508 Wearing of life jackets. (a) The master of a vessel shall require passengers to don life jackets when possible hazardous conditions exist, including, but not limited to: (1...

  19. 46 CFR 122.508 - Wearing of life jackets.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Wearing of life jackets. 122.508 Section 122.508... Preparations for Emergencies § 122.508 Wearing of life jackets. (a) The master of a vessel shall require passengers to don life jackets when possible hazardous conditions exist, including, but not limited to: (1...

  20. 30 CFR 56.15020 - Life jackets and belts.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Life jackets and belts. 56.15020 Section 56.15020 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... § 56.15020 Life jackets and belts. Life jackets or belts shall be worn where there is danger from...

  1. 46 CFR 180.75 - Life jacket lights.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Life jacket lights. 180.75 Section 180.75 Shipping COAST...) LIFESAVING EQUIPMENT AND ARRANGEMENTS Ring Life Buoys and Life Jackets § 180.75 Life jacket lights. (a) Each... light approved in accordance with § 161.012 in subchapter Q of this chapter, or other standard specified...

  2. 46 CFR 180.75 - Life jacket lights.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Life jacket lights. 180.75 Section 180.75 Shipping COAST...) LIFESAVING EQUIPMENT AND ARRANGEMENTS Ring Life Buoys and Life Jackets § 180.75 Life jacket lights. (a) Each... light approved in accordance with § 161.012 in subchapter Q of this chapter, or other standard specified...

  3. 46 CFR 180.75 - Life jacket lights.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Life jacket lights. 180.75 Section 180.75 Shipping COAST...) LIFESAVING EQUIPMENT AND ARRANGEMENTS Ring Life Buoys and Life Jackets § 180.75 Life jacket lights. (a) Each... light approved in accordance with § 161.012 in subchapter Q of this chapter, or other standard specified...

  4. Postexercise Cooling Rates in 2 Cooling Jackets

    PubMed Central

    Brade, Carly; Dawson, Brian; Wallman, Karen; Polglaze, Ted

    2010-01-01

    Abstract Context: Cooling jackets are a common method for removing stored heat accumulated during exercise. To date, the efficiency and practicality of different types of cooling jackets have received minimal investigation. Objective: To examine whether a cooling jacket containing a phase-change material (PC17) results in more rapid postexercise cooling than a gel cooling jacket and a no-jacket (control) condition. Design: Randomized, counterbalanced design with 3 experimental conditions. Setting: Participants exercised at 75% V̇o2max workload in a hot climate chamber (temperature  =  35.0 ± 1.4°C, relative humidity  =  52 ± 4%) for 30 minutes, followed by postexercise cooling for 30 minutes in cool laboratory conditions (ambient temperature  =  24.9 ± 1.8°C, relative humidity  =  39% ± 10%). Patients or Other Participants: Twelve physically active men (age  =  21.3 ± 1.1 years, height  =  182.7 ± 7.1 cm, body mass  =  76.2 ± 9.5 kg, sum of 6 skinfolds  =  50.5 ± 6.9 mm, body surface area  =  1.98 ± 0.14 m2, V̇o2max  =  49.0 ± 7.0 mL·kg−1·min−1) participated. Intervention(s): Three experimental conditions, consisting of a PC17 jacket, a gel jacket, and no jacket. Main Outcome Measure(s): Core temperature (TC), mean skin temperature (TSk), and TC cooling rate (°C/min). Results: Mean peak TC postexercise was 38.49 ± 0.42°C, 38.57 ± 0.41°C, and 38.55 ± 0.40°C for the PC17 jacket, gel jacket, and control conditions, respectively. No differences were observed in peak TC cooling rates among the PC17 jacket (0.038 ± 0.007°C/min), gel jacket (0.040 ± 0.009°C/min), and control (0.034 ± 0.010°C/min, P > .05) conditions. Between trials, no differences were calculated for mean TSk cooling. Conclusions: Similar cooling rates for all 3 conditions indicate that there is no benefit associated with wearing the PC17 or gel jacket. PMID:20210620

  5. 29 CFR Appendix C to Subpart L of... - Fire Protection References For Further Information

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Protection Handbook, National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. B. Accident.... Private Fire Brigades, NFPA 27; National Fire Protection Association, Batterymarch Park, Quincy, MA 02269..., Batterymarch Park, Quincy, MA 02269 . 3. Fire Fighter Professional Qualifications, NFPA 1001; National Fire...

  6. 29 CFR Appendix C to Subpart L of... - Fire Protection References For Further Information

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Protection Handbook, National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. B. Accident.... Private Fire Brigades, NFPA 27; National Fire Protection Association, Batterymarch Park, Quincy, MA 02269..., Batterymarch Park, Quincy, MA 02269 . 3. Fire Fighter Professional Qualifications, NFPA 1001; National Fire...

  7. 29 CFR Appendix C to Subpart L of... - Fire Protection References For Further Information

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Protection Handbook, National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. B. Accident.... Private Fire Brigades, NFPA 27; National Fire Protection Association, Batterymarch Park, Quincy, MA 02269..., Batterymarch Park, Quincy, MA 02269 . 3. Fire Fighter Professional Qualifications, NFPA 1001; National Fire...

  8. DEFLECTION PRESSURE TESTER

    DOEpatents

    Cooper, C.M.

    1961-01-01

    A method and apparatus for determining whether the jacket of a nuclear- fuel slug has a leak are described. The region of the jacket to be leak-tested is sealed off, and gas under pressure is applied thereto. If there is an imperfection, the gas will enter the jacket and bulge another region of the jacket. The bulge occurring is measured by a gage.

  9. CORROSION RESISTANT JACKETED METAL BODY

    DOEpatents

    Brugmann, E.W.

    1958-08-26

    Jacketed metal bodies of the type used as fuel elements for nuclear reactors, which contain an internal elongated body of fissionable material jacketed in a corrosion resistant metal are described. The ends of the internal bodies are provided with screw threads having a tapered outer end. The jacket material overlaps the ends and extends into the tapered section of the screw threaded opening. Screw caps with a mating tapered section are screwed into the ends of the body to compress the jacket material in the tapered sections to provtde an effective seal against corrosive gases and liquids.

  10. 78 FR 55765 - Compensatory and Alternative Regulatory Measures for Nuclear Power Plant Fire Protection (CARMEN...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-11

    ... Nuclear Power Plant Fire Protection (CARMEN-FIRE) AGENCY: Nuclear Regulatory Commission. ACTION: Draft..., ``Compensatory and Alternative Regulatory Measures for Nuclear Power Plant Fire Protection (CARMEN-FIRE).'' In... integral part of NRC-approved fire protection programs. However, compensatory measures are not expected to...

  11. 14 CFR 23.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Flammable fluid fire protection. 23.863... Construction Fire Protection § 23.863 Flammable fluid fire protection. (a) In each area where flammable fluids... protective devices. (4) Means available for controlling or extinguishing a fire, such as stopping flow of...

  12. Idaho National Engineering and Environmental Laboratory Wildland Fire Management Environmental Assessment - April 2003

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Irving, J.S.

    DOE prepared an environmental assessment (EA)for wildland fire management activities on the Idaho National Engineering and Environmental Laboratory (INEEL) (DOE/EA-1372). The EA was developed to evaluate wildland fire management options for pre-fire, fire suppression, and post fire activities. Those activities have an important role in minimizing the conversion of the native sagebrush steppe ecosystem found on the INEEL to non-native weeds. Four alternative management approaches were analyzed: Alternative 1 - maximum fire protection; Alternative 2 - balanced fire protection; Alternative 2 - balanced fire protection; Alternative 3 - protect infrastructure and personnel; and Alternative 4 - no action/traditional fire protection.

  13. Idaho National Engineering and Environmental Laboratory Wildland Fire Management Environmental Assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Irving, John S

    DOE prepared an environmental assessment (EA)for wildland fire management activities on the Idaho National Engineering and Environmental Laboratory (INEEL) (DOE/EA-1372). The EA was developed to evaluate wildland fire management options for pre-fire, fire suppression, and post fire activities. Those activities have an important role in minimizing the conversion of the native sagebrush steppe ecosystem found on the INEEL to non-native weeds. Four alternative management approaches were analyzed: Alternative 1 - maximum fire protection; Alternative 2 - balanced fire protection; Alternative 2 - balanced fire protection; Alternative 3 - protect infrastructure and personnel; and Alternative 4 - no action/traditional fire protection.

  14. Impact of Fire Suit Ensembles on Firefighter PAH Exposures as Assessed by Skin Deposition and Urinary Biomarkers.

    PubMed

    Wingfors, Håkan; Nyholm, Jenny Rattfelt; Magnusson, Roger; Wijkmark, Cecilia Hammar

    2018-02-13

    Over the past 10 years, a number of safety measures for reducing firefighters' exposure to combustion particles have been introduced in Sweden. The most important measure was the reduction in the time firefighters wear suits and handle contaminated equipment after turn-outs involving smoke diving. This study was divided into two parts, those being to investigate the level of protection obtained by multiple garment layers and to assess exposure during a standardized smoke diving exercise. First, realistic work protection factors (WPFs) were calculated by comparing air concentrations of the full suite of gaseous and particle-bound polycyclic aromatic hydrocarbons (PAHs) inside and outside structural ensembles, including jacket and thick base layer, during a tough fire extinguishing exercise using wood as the fuel. Second, during a standardized smoke diving exercise, exposure was assessed by measuring PAH skin deposition and levels of eight urinary PAH metabolites in 20 volunteer student firefighters before and after the exercise. The average WPF for the sum of 22 PAHs was 146 ± 33 suggesting a relatively high protective capacity but also indicating a substantial enrichment of contaminants with a risk of prolonged dermal exposure. Accordingly, in the second exercise, the median levels of skin-deposited Σ14-PAHs and urinary 1-hydroxypyrene significantly increased 5-fold (21 to 99 ng/wipe) and 8-fold (0.14 to 1.1 µmol mol-1 creatinine), respectively, post exposure. Among the PAH metabolites investigated, 1-hydroxypyrene proved to be the most useful indicator of exposure, with significantly elevated urinary levels at both 6 h and 20 h after the exercise and with the strongest correlation to dermal exposure. Metabolites from two-ring and three-ring PAHs were eliminated faster while levels of 3-hydroxy-benzo[a]pyrene did not meet the detection criteria. The results from correlation studies indicated that dermal uptake was a major route of exposure in accordance with previous findings. To summarize, this study shows that some of the newly adopted protective measures were correctly implemented, and should continue to be followed and be more widely adopted. © The Author(s) 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  15. 49 CFR 173.323 - Ethylene oxide.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... (5 gallons) capacity. Cylinders must be seamless or welded steel (not brazed) with a nominal capacity... Pamphlet C-14 or other equivalent method. (3) In 1A1 steel drums of no more than 231 L (61 gallons) and... must be protected with a steel jacket at least 2.54 mm (0.100 inch) thick, or as required by the...

  16. 49 CFR 173.323 - Ethylene oxide.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... (5 gallons) capacity. Cylinders must be seamless or welded steel (not brazed) with a nominal capacity... Pamphlet C-14 or other equivalent method. (3) In 1A1 steel drums of no more than 231 L (61 gallons) and... must be protected with a steel jacket at least 2.54 mm (0.100 inch) thick, or as required by the...

  17. 49 CFR 173.323 - Ethylene oxide.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... (5 gallons) capacity. Cylinders must be seamless or welded steel (not brazed) with a nominal capacity... Pamphlet C-14 or other equivalent method. (3) In 1A1 steel drums of no more than 231 L (61 gallons) and... must be protected with a steel jacket at least 2.54 mm (0.100 inch) thick, or as required by the...

  18. 49 CFR 173.323 - Ethylene oxide.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... (5 gallons) capacity. Cylinders must be seamless or welded steel (not brazed) with a nominal capacity... Pamphlet C-14 or other equivalent method. (3) In 1A1 steel drums of no more than 231 L (61 gallons) and... must be protected with a steel jacket at least 2.54 mm (0.100 inch) thick, or as required by the...

  19. 49 CFR 193.2801 - Fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Fire protection. 193.2801 Section 193.2801...: FEDERAL SAFETY STANDARDS Fire Protection § 193.2801 Fire protection. Each operator must provide and maintain fire protection at LNG plants according to sections 9.1 through 9.7 and section 9.9 of NFPA 59A...

  20. Archway for Radiation and Micrometeorite Occurrence Resistance

    NASA Technical Reports Server (NTRS)

    Giersch, Louis R.

    2012-01-01

    The environmental conditions of the Moon require mitigation if a long-term human presence is to be achieved for extended periods of time. Radiation, micrometeoroid impacts, high-velocity debris, and thermal cycling represent threats to crew, equipment, and facilities. For decades, local regolith has been suggested as a candidate material to use in the construction of protective barriers. A thickness of roughly 3m is sufficient protection from both direct and secondary radiation from cosmic rays and solar protons; this thickness is sufficient to reduce radiation exposure even during solar flares. NASA has previously identified a need for innovations that will support lunar habitats using lightweight structures because the reduction of structural mass translates directly into additional up and down mass capability that would facilitate additional logistics capacity and increased science return for all mission phases. The development of non-pressurized primary structures that have synergy with the development of pressurized structures is also of interest. The use of indigenous or in situ materials is also a well-known and active area of research that could drastically improve the practicality of human exploration beyond low-Earth orbit. The Archway for Radiation and Micrometeorite Occurrence Resistance (ARMOR) concept is a new, multifunctional structure that acts as radiation shielding and micrometeorite impact shielding for long-duration lunar surface protection of humans and equipment. ARMOR uses a combination of native regolith and a deployed membrane jacket to yield a multifunctional structure. ARMOR is a robust and modular system that can be autonomously assembled on-site prior to the first human surface arrival. The system provides protection by holding a sufficiently thick (3 m) archshaped shell of local regolith around a central cavity. The regolith is held in shape by an arch-shaped jacket made of strong but deployable material. No regolith processing is required. During the regolith filling process, an inflatable structure under the arch supports the mass of the regolith, but once regolith filling is complete the catenary arch formed by the regolith and the jacket becomes self-supporting and the inflatable can be deflated and removed. When complete, habitat modules and equipment can be moved into the protected cavity under the arch. ARMOR is a nearterm system that would provide a reliable and robust lightweight structure technology to support large lunar habitats, drastically lower launch mass, and improve efficient volume use, reducing launch costs.

  1. Factors associated with life jacket use among cabin sailboat and day sailor boaters in the United States.

    PubMed

    Spitzer, Natalie; Phillips, Maile T; Chow, Wendy; Mangione, Thomas W

    2018-06-01

    In 2015, drowning accounted for 68% of the 626 recreational boating related deaths in the United States. Although life jackets are estimated to prevent between 50% to 80% of boating deaths, approximately 83% of sailboat-related drowning victims were reported to not be wearing life jackets. Life jacket use among adult boaters has remained consistently low across most boat types and may vary by boater, boating, and environmental conditions. Although many risky environmental and boating factors may be associated with a higher risk of boating death, drowning occurs in all situations and it is useful to understand adult life jacket wearing behaviors in differing boating situations. This study uses observational survey data from 61318 adult sailors collected during the summer months of 1999 - 2017 from 124 selected study sites across 30 states in the US. Life jacket use was compared for day sailors and cabin sailboats by multiple boating, boater, and environmental conditions using Chi-square tests for equality of proportions. Results of these tests led to a choice of 3 informative and scientifically compelling variables to summarize variation in life jacket use for each sailboat type. Odds ratios were calculated comparing life jacket use from each boating situation to the lowest risk situation as determined by the 3 selected variables. These variables were represented in a tree diagram, detailing the additive impact of each factor. Following these analyses, all boating conditions were categorized to be risky or non-risky and a count variable was created for each observation based on the number of risks present. Cochran-Armitage trend tests were conducted to test for linearity in life jacket use for both boat types. The overall life jacket wear rate was higher among adults in day sailor sailboats (51.6%) compared to cabin sailboats (13.8%) and in all measured demographic, boating, and environmental circumstances. Comparing high-risk cabin sailboat conditions of low water temperatures, small boat size, and high wind speed to the lowest-risk situation accounted for a 23.3% range in life jacket wear rate (OR=4.7). Comparing high-risk day sailor sailboat conditions of small boat size, one boater on board, and choppy/rough wave height to the lowest-risk situation accounted for a 39.3% range in life jacket wear rate (OR=5.9). For both boat types, the number of risks present and life jacket wear rate exhibited a statistically significant positive linear relationship at p<0.0001. Study results suggest that boaters are aware of the connection between life jacket use and drowning prevention and are more likely to wear life jackets when boating in conditions perceived to be risky. Boating safety promotion efforts should recommend adult life jacket use in all boating situations, as seemingly non-risky conditions may still result in drownings. Copyright © 2018. Published by Elsevier Ltd.

  2. Angled shots onto body armour using 9 mm ammunition: the effect on potential blunt injury.

    PubMed

    Lyall, Alison; Carr, D J; Lankester, C; Malbon, C

    2017-02-01

    Some military specialists wear body armour that is more similar to police armour and provides protection from ammunition fired from pistols. During ballistic testing, these armours are mounted on a standardised type of modelling clay and the back face signature (BFS; depth of depression) formed as a result of the non-perforating impact event on to the armour is measured. This study investigated the effect of impact angle on the BFS and on the deformation of the bullet. Two commonly worn types of armour (HG1/A+KR1 and HG1+KR1) were considered that provide protection from pistol ammunition and sharp weapons. Armours were tested against two types of pistol ammunition (9 mm full metal jacket and 9 mm hollow point) at eight different impact angles (0°, 15°, 30°, 45°, 60°, 70°, 75° and 80°). Increased impact angles resulted in smaller BFSs. Impact angle also affected whether bullets were retained in the armour; as the impact angle increased, the probability of a round exiting the side of the armour increased. Bullet deformation was affected by impact angle. Understanding the deformation of bullets may assist with recreating a shooting incident and interpreting forensic evidence. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  3. Foam Insulation for Cryogenic Flowlines

    NASA Technical Reports Server (NTRS)

    Sonju, T. R.; Carbone, R. L.; Oves, R. E.

    1985-01-01

    Welded stainless-steel vacuum jackets on cryogenic ducts replaced by plastic foam-insulation jackets that weigh 12 percent less. Foam insulation has 85 percent of insulating ability of stainless-steel jacketing enclosing vacuum of 10 microns of mercury. Foam insulation easier to install than vacuum jacket. Moreover, foam less sensitive to damage and requires minimal maintenance. Resists vibration and expected to have service life of at least 10 years.

  4. Fire protection review revisit no. 2, Argonne National Laboratory, Argonne, Illinois

    NASA Astrophysics Data System (ADS)

    Dobson, P. H.; Earley, M. W.; Mattern, L. J.

    1985-05-01

    A fire protection survey was conducted at Argonne National Laboratory on April 1-5, 8-12, and April 29-May 2, 1985. The purpose was to review the facility fire protection program and to make recommendations or identify areas according to criteria established by the Department of Energy. There has been a substantial improvement in fire protection at this laboratory since the 1977 audit. Numerous areas which were previously provided with detection systems only have since been provided with automatic sprinkler protection. The following basic fire protection features are not properly controlled: (1) resealing wall and floor penetrations between fire areas after installation of services; (2) cutting and welding; and (3) housekeeping. The present Fire Department manpower level appears adequate to control a route fire. Their ability to adequately handle a high-challenge fire, or one involving injuries to personnel, or fire spread beyond the initial fire area is doubtful.

  5. 29 CFR 1926.150 - Fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Fire protection. 1926.150 Section 1926.150 Labor... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Fire Protection and Prevention § 1926.150 Fire protection. (a) General requirements. (1) The employer shall be responsible for the development of a fire...

  6. Water jacket for solid particle solar receiver

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wasyluk, David T.

    A solar receiver includes: water jacket panels each having a light-receiving side and a back side with a watertight sealed plenum defined in-between; light apertures passing through the watertight sealed plenums to receive light from the light-receiving sides of the water jacket panels; a heat transfer medium gap defined between the back sides of the water jacket panels and a cylindrical back plate; and light channeling tubes optically coupled with the light apertures and extending into the heat transfer medium gap. In some embodiments ends of the light apertures at the light receiving side of the water jacket panel aremore » welded together to define at least a portion of the light-receiving side. A cylindrical solar receiver may be constructed using a plurality of such water jacket panels arranged with their light-receiving sides facing outward.« less

  7. JacketSE: An Offshore Wind Turbine Jacket Sizing Tool; Theory Manual and Sample Usage with Preliminary Validation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Damiani, Rick

    This manual summarizes the theory and preliminary verifications of the JacketSE module, which is an offshore jacket sizing tool that is part of the Wind-Plant Integrated System Design & Engineering Model toolbox. JacketSE is based on a finite-element formulation and on user-prescribed inputs and design standards' criteria (constraints). The physics are highly simplified, with a primary focus on satisfying ultimate limit states and modal performance requirements. Preliminary validation work included comparing industry data and verification against ANSYS, a commercial finite-element analysis package. The results are encouraging, and future improvements to the code are recommended in this manual.

  8. Non-intrusive cooling system

    DOEpatents

    Morrison, Edward F.; Bergman, John W.

    2001-05-22

    A readily replaceable heat exchange cooling jacket for applying fluid to a system conduit pipe. The cooling jacket comprises at least two members, separable into upper and lower portions. A chamber is formed between the conduit pipe and cooling jacket once the members are positioned about the pipe. The upper portion includes a fluid spray means positioned above the pipe and the bottom portion includes a fluid removal means. The heat exchange cooling jacket is adaptable with a drain tank, a heat exchanger, a pump and other standard equipment to provide a system for removing heat from a pipe. A method to remove heat from a pipe, includes the steps of enclosing a portion of the pipe with a jacket to form a chamber between an outside surface of the pipe and the cooling jacket; spraying cooling fluid at low pressure from an upper portion of the cooling jacket, allowing the fluid to flow downwardly by gravity along the surface of the pipe toward a bottom portion of the chamber; and removing the fluid at the bottom portion of the chamber.

  9. Passive fire building protection system evaluation (case study: millennium ict centre)

    NASA Astrophysics Data System (ADS)

    Rahman, Vinky; Stephanie

    2018-03-01

    Passive fire protection system is a system that refers to the building design, both regarding of architecture and structure. This system usually consists of structural protection that protects the structure of the building and prevents the spread of fire and facilitate the evacuation process in case of fire. Millennium ICT Center is the largest electronic shopping center in Medan, Indonesia. As a public building that accommodates the crowd, this building needs a fire protection system by the standards. Therefore, the purpose of this study is to evaluate passive fire protection system of Millennium ICT Center building. The study was conducted to describe the facts of the building as well as direct observation to the research location. The collected data is then processed using the AHP (Analytical Hierarchy Process) method in its weighting process to obtain the reliability value of passive fire protection fire system. The results showed that there are some components of passive fire protection system in the building, but some are still unqualified. The first section in your paper

  10. 29 CFR 1915.507 - Land-side fire protection systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 7 2013-07-01 2013-07-01 false Land-side fire protection systems. 1915.507 Section 1915... Protection in Shipyard Employment § 1915.507 Land-side fire protection systems. (a) Employer responsibilities. The employer must ensure all fixed and portable fire protection systems needed to meet an OSHA...

  11. 29 CFR 1915.507 - Land-side fire protection systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 7 2012-07-01 2012-07-01 false Land-side fire protection systems. 1915.507 Section 1915... Protection in Shipyard Employment § 1915.507 Land-side fire protection systems. (a) Employer responsibilities. The employer must ensure all fixed and portable fire protection systems needed to meet an OSHA...

  12. 29 CFR 1915.507 - Land-side fire protection systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 7 2011-07-01 2011-07-01 false Land-side fire protection systems. 1915.507 Section 1915... Protection in Shipyard Employment § 1915.507 Land-side fire protection systems. (a) Employer responsibilities. The employer must ensure all fixed and portable fire protection systems needed to meet an OSHA...

  13. 29 CFR 1915.507 - Land-side fire protection systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 7 2014-07-01 2014-07-01 false Land-side fire protection systems. 1915.507 Section 1915... Protection in Shipyard Employment § 1915.507 Land-side fire protection systems. (a) Employer responsibilities. The employer must ensure all fixed and portable fire protection systems needed to meet an OSHA...

  14. 78 FR 45573 - Compensatory and Alternative Regulatory Measures for Nuclear Power Plant Fire Protection (CARMEN...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-29

    ... Nuclear Power Plant Fire Protection (CARMEN-FIRE) AGENCY: Nuclear Regulatory Commission. ACTION: Notice of... Nuclear Power Plant Fire Protection (CARMEN-FIRE), Draft Report for Comment.'' DATES: Comments on this... CONTACT: Felix Gonzalez, Fire Research Branch, Division of Risk Analysis, Office of Nuclear Regulatory...

  15. Risks, designs, and research for fire safety in spacecraft

    NASA Technical Reports Server (NTRS)

    Friedman, Robert; Sacksteder, Kurt R.; Urban, David

    1991-01-01

    Current fire protection for spacecraft relies mainly on fire prevention through the use of nonflammable materials and strict storage controls of other materials. The Shuttle also has smoke detectors and fire extinguishers, using technology similar to aircraft practices. While experience has shown that the current fire protection is adequate, future improvements in fire safety technology to meet the challenges of long duration space missions, such as the Space Station Freedom, are essential. All spacecraft fire protection systems, however, must deal with the unusual combustion characteristics and operational problems in the low gravity environment. The features of low gravity combustion that affect spacecraft fire safety, and the issues in fire protection for Freedom that must be addressed eventually to provide effective and conservative fire protection systems are discussed.

  16. Gunshot energy transfer profile in ballistic gelatine, determined with computed tomography using the total crack length method.

    PubMed

    Bolliger, Stephan A; Thali, Michael J; Bolliger, Michael J; Kneubuehl, Beat P

    2010-11-01

    By measuring the total crack lengths (TCL) along a gunshot wound channel simulated in ordnance gelatine, one can calculate the energy transferred by a projectile to the surrounding tissue along its course. Visual quantitative TCL analysis of cut slices in ordnance gelatine blocks is unreliable due to the poor visibility of cracks and the likely introduction of secondary cracks resulting from slicing. Furthermore, gelatine TCL patterns are difficult to preserve because of the deterioration of the internal structures of gelatine with age and the tendency of gelatine to decompose. By contrast, using computed tomography (CT) software for TCL analysis in gelatine, cracks on 1-cm thick slices can be easily detected, measured and preserved. In this, experiment CT TCL analyses were applied to gunshots fired into gelatine blocks by three different ammunition types (9-mm Luger full metal jacket, .44 Remington Magnum semi-jacketed hollow point and 7.62 × 51 RWS Cone-Point). The resulting TCL curves reflected the three projectiles' capacity to transfer energy to the surrounding tissue very accurately and showed clearly the typical energy transfer differences. We believe that CT is a useful tool in evaluating gunshot wound profiles using the TCL method and is indeed superior to conventional methods applying physical slicing of the gelatine.

  17. A new model for the characterization of infection risk in gunshot injuries:Technology, principal consideration and clinical implementation

    PubMed Central

    2011-01-01

    Introduction The extent of wound contamination in gunshot injuries is still a topic of controversial debate. The purpose of the present study is to develop a model that illustrates the contamination of wounds with exogenous particles along the bullet path. Material and methods To simulate bacteria, radio-opaque barium titanate (3-6 μm in diameter) was atomized in a dust chamber. Full metal jacket or soft point bullets caliber .222 (n = 12, v0 = 1096 m/s) were fired through the chamber into a gelatin block directly behind it. After that, the gelatin block underwent multi-slice CT in order to analyze the permanent and temporary wound cavity. Results The permanent cavity caused by both types of projectiles showed deposits of barium titanate distributed over the entire bullet path. Full metal jacket bullets left only few traces of barium titanate in the temporary cavity. In contrast, the soft point bullets disintegrated completely, and barium titanate covered the entire wound cavity. Discussion Deep penetration of potential exogenous bacteria can be simulated easily and reproducibly with barium titanate particles shot into a gelatin block. Additionally, this procedure permits conclusions to be drawn about the distribution of possible contaminants and thus can yield essential findings in terms of necessary therapeutic procedures. PMID:22032229

  18. School Fire Protection: Contents Count

    ERIC Educational Resources Information Center

    American School and University, 1976

    1976-01-01

    The heart of a fire protection system is the sprinkler system. National Fire Protection Association (NFPA) statistics show that automatic sprinklers dramatically reduce fire damage and loss of life. (Author)

  19. Strengthening and repair of RC beams with sugarcane bagasse fiber reinforced cement mortar

    NASA Astrophysics Data System (ADS)

    Syamir Senin, Mohamad; Shahidan, Shahiron; Maarof, M. Z. Md; Syazani Leman, Alif; Zuki, S. S. Mohd; Azmi, M. A. Mohammad

    2017-11-01

    The use of a jacket made of fiber reinforced cement mortar with tensile hardening behaviour for strengthening RC beams was investigated in this study. A full-scale test was conducted on beams measuring 1000mm in length. A 25mm jacket was directly applied to the surface of the beams to test its ability to repair and strengthen the beams. The beams were initially damaged and eventually repaired. Three types of beams which included unrepaired beams, beams repaired with normal mortar jacket and beams repaired with 10% sugarcane bagasse fiber mortar jacket were studied. The jacket containing 10% of sugarcane bagasse fiber enhanced the flexural strength of the beams.

  20. The effect on engine performance of change in jacket-water outlet temperature

    NASA Technical Reports Server (NTRS)

    Garlock, E A; Ellis, Greer

    1933-01-01

    Tests made on a Curtiss D-12 engine in the Altitude Laboratory at the Bureau of Standards show the following effects on engine performance of change in jacket-water outlet temperature: 1) Friction at all altitudes is a linear function of the jacket-water temperature, decreasing with increasing temperature. 2) The brake horsepower below an altitude of about 9,000 feet decreases, and at higher altitudes increases, with jacket-water temperature. 3) The brake specific fuel consumption tends to decrease, at all altitudes, with increasing jacket-water temperature. 4) The percentage change in brake power output is roughly equal to the algebraic sum of the percentage change in volumetric efficiency and mechanical efficiency.

  1. WELDED JACKETED URANIUM BODY

    DOEpatents

    Gurinsky, D.H.

    1958-08-26

    A fuel element is presented for a neutronic reactor and is comprised of a uranium body, a non-fissionable jacket surrounding sald body, thu jacket including a portion sealed by a weld, and an inclusion in said sealed jacket at said weld of a fiux having a low neutron capture cross-section. The flux is provided by combining chlorine gas and hydrogen in the intense heat of-the arc, in a "Heliarc" welding muthod, to form dry hydrochloric acid gas.

  2. 76 FR 40777 - Interim Enforcement Policy for Certain Fire Protection Issues

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-12

    ... Certain Fire Protection Issues AGENCY: Nuclear Regulatory Commission. ACTION: Policy statement; revision... Enforcement Policy on enforcement discretion for certain fire protection issues to extend the enforcement... policy affects licensees that are transitioning to use the National Fire Protection Association Standard...

  3. Fire-danger rating in the future.

    Treesearch

    James E. Hefner

    1967-01-01

    The forest resources of this country must be protected from wildfire. Protection does not eliminate fire but does reduce loss from fire. In recent years, more acres have been burned on the unprotected 3 percent of forest land than on the 97 percent under organized fire protection. Protection from fire has saved more than 100 million acres per year. This figure is based...

  4. 14 CFR 25.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Combustion heater fire protection. 25.859....859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... surrounds the combustion chamber. However, no fire extinguishment is required in cabin ventilating air...

  5. 14 CFR 25.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Combustion heater fire protection. 25.859....859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... surrounds the combustion chamber. However, no fire extinguishment is required in cabin ventilating air...

  6. 14 CFR 25.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Combustion heater fire protection. 25.859....859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... surrounds the combustion chamber. However, no fire extinguishment is required in cabin ventilating air...

  7. 14 CFR 25.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Combustion heater fire protection. 25.859....859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... surrounds the combustion chamber. However, no fire extinguishment is required in cabin ventilating air...

  8. 14 CFR 25.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Combustion heater fire protection. 25.859....859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... surrounds the combustion chamber. However, no fire extinguishment is required in cabin ventilating air...

  9. Insulative laser shell coupler

    DOEpatents

    Arnold, Phillip A.; Anderson, Andrew T.; Alger, Terry W.

    1994-01-01

    A segmented coaxial laser shell assembly having at least two water jacket sections, two pairs of interconnection half rings, a dialectric break ring, and a pair of threaded ring sections. Each water jacket section with an inner tubular section that defines an inner laser cavity with water paths adjacent to at least a portion of the exterior of the inner tubular section, and mating faces at the end of the water jacket section through which the inner laser cavity opens and which defines at least one water port therethrough in communication with the water jackets. The water paths also define in their external surface a circumferential notch set back from and in close proximity to the mating face. The dielectric break ring has selected thickness and is placed between, and in coaxial alignment with, the mating faces of two of the adjacent water jacket sections. The break ring also defines an inner laser cavity of the same size and shape as the inner laser cavity of the water jacket sections and at least one water passage through the break ring to communicate with at least one water port through the mating faces of the water jacket sections.

  10. Insulative laser shell coupler

    DOEpatents

    Arnold, P.A.; Anderson, A.T.; Alger, T.W.

    1994-09-20

    A segmented coaxial laser shell assembly having at least two water jacket sections, two pairs of interconnection half rings, a dielectric break ring, and a pair of threaded ring sections is disclosed. Each water jacket section with an inner tubular section that defines an inner laser cavity with water paths adjacent to at least a portion of the exterior of the inner tubular section, and mating faces at the end of the water jacket section through which the inner laser cavity opens and which defines at least one water port therethrough in communication with the water jackets. The water paths also define in their external surface a circumferential notch set back from and in close proximity to the mating face. The dielectric break ring has selected thickness and is placed between, and in coaxial alignment with, the mating faces of two of the adjacent water jacket sections. The break ring also defines an inner laser cavity of the same size and shape as the inner laser cavity of the water jacket sections and at least one water passage through the break ring to communicate with at least one water port through the mating faces of the water jacket sections. 4 figs.

  11. Cost-benefit analysis of passive fire protections in road LPG transportation.

    PubMed

    Paltrinieri, Nicola; Bonvicini, Sarah; Spadoni, Gigliola; Cozzani, Valerio

    2012-02-01

    The cost-benefit evaluation of passive fire protection adoption in the road transport of liquefied petroleum gas (LPG) was investigated. In a previous study, mathematical simulations of real scale fire scenarios proved the effectiveness of passive fire protections in preventing the "fired" boiling liquid expanding vapor explosion (BLEVE), thus providing a significant risk reduction. In the present study the economical aspects of the adoption of fire protections are analyzed and an approach to cost-benefit analysis (CBA) is proposed. The CBA model is based on the comparison of the risk reduction due to fire protections (expressed in monetary terms by the value of a statistical life) and the cost of the application of fire protections to a fleet of tankers. Different types of fire protections were considered, as well as the possibility to apply protections to the entire fleet or only to a part of it. The application of the proposed model to a real-life case study is presented and discussed. Results demonstrate that the adoption of passive fire protections on road tankers, though not compulsory in Europe, can be economically feasible, thus representing a concrete measure to achieve control of the "major hazard accidents" cited by the European legislation. © 2011 Society for Risk Analysis.

  12. Innovative 3D Textile Structures for Soft Body Armor Protection: The EPIDARM Project

    NASA Astrophysics Data System (ADS)

    Maillet, Jérôme; Lefebvre, Marie; Boussu, François; Pirlot, Marc

    There is a real need for battlefield soldiers to be protected from ­ballistic and CBRNE threats and also to be in permanent contact and localization with the logistic support of the commander. Ballistic, CBRNE and tactical jackets are currently three different components, developed separately and worn on top of each other. One of the EPIDARM project's targets is to propose a personal protection demonstration for the optimal system configuration in order to reduce the cost and weight while improving protection. The systems approach used for the EPIDARM program considers the protective system inside its environment (threat, the wearer - generic soldier, task and climates). The latest emergent technologies in ballistic and CBRN protection, ergonomic effectiveness and financial cost are considered and help to select final solutions.

  13. 46 CFR 115.808 - Lifesaving.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...) Inspection of each life jacket, work vest, and marine buoyant device; (3) If used, inspection of the... of each inflatable liferaft, inflatable buoyant apparatus, and inflatable life jacket to determine... managing operator shall destroy, in the presence of the marine inspector, each life jacket, other personal...

  14. CORROSION RESISTANT JACKETED METAL BODY

    DOEpatents

    Brugmann, E.W.

    1958-08-26

    S>Metal jacketed metallic bodies of the type used as feel elements fer nuclear reactors are presented. The fuel element is comprised of a plurality of jacketed cylindrical bodies joined in end to end abutting relationship. The abutting ends of the internal fissionable bodies are provided with a mating screw and thread means for joining the two together. The jacket material is of a corrosion resistant metal and overlaps the abutting ends of the internal bodies, thereby effectively sealing these bodies from contact with exteral reactive gases and liquids.

  15. 46 CFR 72.05-40 - Insulation, other than for structural fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... VESSELS CONSTRUCTION AND ARRANGEMENT Structural Fire Protection § 72.05-40 Insulation, other than for structural fire protection. (a) Any insulation installed for heat and comfort, refrigeration (including air... 46 Shipping 3 2012-10-01 2012-10-01 false Insulation, other than for structural fire protection...

  16. 46 CFR 72.05-40 - Insulation, other than for structural fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... VESSELS CONSTRUCTION AND ARRANGEMENT Structural Fire Protection § 72.05-40 Insulation, other than for structural fire protection. (a) Any insulation installed for heat and comfort, refrigeration (including air... 46 Shipping 3 2010-10-01 2010-10-01 false Insulation, other than for structural fire protection...

  17. 46 CFR 72.05-40 - Insulation, other than for structural fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... VESSELS CONSTRUCTION AND ARRANGEMENT Structural Fire Protection § 72.05-40 Insulation, other than for structural fire protection. (a) Any insulation installed for heat and comfort, refrigeration (including air... 46 Shipping 3 2014-10-01 2014-10-01 false Insulation, other than for structural fire protection...

  18. 46 CFR 72.05-40 - Insulation, other than for structural fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... VESSELS CONSTRUCTION AND ARRANGEMENT Structural Fire Protection § 72.05-40 Insulation, other than for structural fire protection. (a) Any insulation installed for heat and comfort, refrigeration (including air... 46 Shipping 3 2011-10-01 2011-10-01 false Insulation, other than for structural fire protection...

  19. 46 CFR 72.05-40 - Insulation, other than for structural fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... VESSELS CONSTRUCTION AND ARRANGEMENT Structural Fire Protection § 72.05-40 Insulation, other than for structural fire protection. (a) Any insulation installed for heat and comfort, refrigeration (including air... 46 Shipping 3 2013-10-01 2013-10-01 false Insulation, other than for structural fire protection...

  20. 41 CFR 102-80.135 - Who is a qualified fire protection engineer?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... protection engineer? 102-80.135 Section 102-80.135 Public Contracts and Property Management Federal Property... qualified fire protection engineer? A qualified fire protection engineer is defined as an individual with a thorough knowledge and understanding of the principles of physics and chemistry governing fire growth...

  1. 14 CFR 23.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Flammable fluid fire protection. 23.863... Construction Fire Protection § 23.863 Flammable fluid fire protection. (a) In each area where flammable fluids... fluids, shutting down equipment, fireproof containment, or use of extinguishing agents. (5) Ability of...

  2. 14 CFR 23.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Flammable fluid fire protection. 23.863... Construction Fire Protection § 23.863 Flammable fluid fire protection. (a) In each area where flammable fluids... fluids, shutting down equipment, fireproof containment, or use of extinguishing agents. (5) Ability of...

  3. 14 CFR 23.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Flammable fluid fire protection. 23.863... Construction Fire Protection § 23.863 Flammable fluid fire protection. (a) In each area where flammable fluids... fluids, shutting down equipment, fireproof containment, or use of extinguishing agents. (5) Ability of...

  4. 14 CFR 23.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Flammable fluid fire protection. 23.863... Construction Fire Protection § 23.863 Flammable fluid fire protection. (a) In each area where flammable fluids... fluids, shutting down equipment, fireproof containment, or use of extinguishing agents. (5) Ability of...

  5. 76 FR 70413 - National Fire Protection Association (NFPA): Request for Comments on NFPA's Codes and Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-14

    ... DEPARTMENT OF COMMERCE National Institute of Standards and Technology National Fire Protection... (NIST) is publishing this notice on behalf of the National Fire Protection Association (NFPA) to..., (301) 975-4019. SUPPLEMENTARY INFORMATION: Since 1896, the National Fire Protection Association (NFPA...

  6. 46 CFR 176.810 - Fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Fire protection. 176.810 Section 176.810 Shipping COAST...) INSPECTION AND CERTIFICATION Material Inspections § 176.810 Fire protection. (a) At each initial and... and have the vessel ready for inspection of its fire protection equipment, including the following: (1...

  7. 46 CFR 194.20-7 - Fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Fire protection. 194.20-7 Section 194.20-7 Shipping... Fire protection. (a) Each chemical storeroom shall be protected by a fixed automatic carbon dioxide... fire extinguishers are required in accordance with Table 193.50-10(a) of this subchapter. ...

  8. Vacuum-jacketed transfer line installation technique

    NASA Technical Reports Server (NTRS)

    Bowers, W. M.

    1968-01-01

    Rolling-type spacers in the form of steel balls retained in appropriate sleeves affixed at intervals to the exterior of the transfer line facilitate the installation of a vacuum-jacketed line. They act as standoffs to position the transfer line concentrically within the vacuum jacket line.

  9. Fire Protection in Educational Occupancies.

    ERIC Educational Resources Information Center

    Gervais, Romeo P.

    2000-01-01

    Discusses the origins of school fires and the components of the fire protection code called the Life Safety Code (LSC). Three of the following LSC requirements are described: means of egress; protection from hazards; and fire suppression and alarm systems. Information on who starts fires is highlighted along with preventive measures. (GR)

  10. 14 CFR 33.17 - Fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire protection. 33.17 Section 33.17... STANDARDS: AIRCRAFT ENGINES Design and Construction; General § 33.17 Fire protection. (a) The design and... fire during normal operation and failure conditions, and must minimize the effect of such a fire. In...

  11. Space environmental considerations for a long-term cryogenic storage vessel

    NASA Technical Reports Server (NTRS)

    Nakanishi, Shigeo

    1987-01-01

    Information is given on the kind of protection that is needed against impact and perforation of a long-term cryogenic storage vessel in space by meteoroids and space debris. The long-term effects of the space environment on thermal control surfaces and coatings, and the question of whether the insulation and thermal control surfaces should be encased in a vacuum jacket shell are discussed.

  12. Comparing the cyclic behavior of concrete cylinders confined by shape memory alloy wire or steel jackets

    NASA Astrophysics Data System (ADS)

    Park, Joonam; Choi, Eunsoo; Park, Kyoungsoo; Kim, Hong-Taek

    2011-09-01

    Shape memory alloy (SMA) wire jackets for concrete are distinct from conventional jackets of steel or fiber reinforced polymer (FRP) since they provide active confinement which can be easily achieved due to the shape memory effect of SMAs. This study uses NiTiNb SMA wires of 1.0 mm diameter to confine concrete cylinders with the dimensions of 300 mm × 150 mm (L × D). The NiTiNb SMAs have a relatively wider temperature hysteresis than NiTi SMAs; thus, they are more suitable for the severe temperature-variation environments to which civil structures are exposed. Steel jackets of passive confinement are also prepared in order to compare the cyclic behavior of actively and passively confined concrete cylinders. For this purpose, monotonic and cyclic compressive loading tests are conducted to obtain axial and circumferential strain. Both strains are used to estimate the volumetric strains of concrete cylinders. Plastic strains from cyclic behavior are also estimated. For the cylinders jacketed by NiTiNb SMA wires, the monotonic axial behavior differs from the envelope of cyclic behavior. The plastic strains of the actively confined concrete show a similar trend to those of passive confinement. This study proposed plastic strain models for concrete confined by SMA wire or steel jackets. For the volumetric strain, the active jackets of NiTiNb SMA wires provide more energy dissipation than the passive jacket of steel.

  13. Applications of Living Fire PRA models to Fire Protection Significance Determination Process in Taiwan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    De-Cheng, Chen; Chung-Kung, Lo; Tsu-Jen, Lin

    2004-07-01

    The living fire probabilistic risk assessment (PRA) models for all three operating nuclear power plants (NPPs) in Taiwan had been established in December 2000. In that study, a scenario-based PRA approach was adopted to systematically evaluate the fire and smoke hazards and associated risks. Using these fire PRA models developed, a risk-informed application project had also been completed in December 2002 for the evaluation of cable-tray fire-barrier wrapping exemption. This paper presents a new application of the fire PRA models to fire protection issues using the fire protection significance determination process (FP SDP). The fire protection issues studied may involvemore » the selection of appropriate compensatory measures during the period when an automatic fire detection or suppression system in a safety-related fire zone becomes inoperable. The compensatory measure can either be a 24-hour fire watch or an hourly fire patrol. The living fire PRA models were used to estimate the increase in risk associated with the fire protection issue in terms of changes in core damage frequency (CDF) and large early release frequency (LERF). In compliance with SDP at-power and the acceptance guidelines specified in RG 1.174, the fire protection issues in question can be grouped into four categories; red, yellow, white and green, in accordance with the guidelines developed for FD SDP. A 24-hour fire watch is suggested only required for the yellow condition, while an hourly fire patrol may be adopted for the white condition. More limiting requirement is suggested for the red condition, but no special consideration is needed for the green condition. For the calculation of risk measures, risk impacts from any additional fire scenarios that may have been introduced, as well as more severe initiating events and fire damages that may accompany the fire protection issue should be considered carefully. Examples are presented in this paper to illustrate the evaluation process. (authors)« less

  14. Thermal-leak analyzer for vacuum-jacketed lines

    NASA Technical Reports Server (NTRS)

    Heisman, R. M.; Iceland, W. F.; Ruppe, E. P.

    1978-01-01

    Technique involves coating suspected area with water-soluble black paint that gives even, infrared emission. Painted area is warmed with heat gun; an infrared scanner is used to detect cooled spot on jacket exterior. Introduction of atmospheric pressure into jacket intensifies leak jet and improves test sensitivity.

  15. 14 CFR 25.865 - Fire protection of flight controls, engine mounts, and other flight structure.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Design and Construction Fire Protection § 25.865 Fire protection of flight controls, engine mounts, and other flight structure. Essential flight controls, engine mounts, and other flight structures located in... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fire protection of flight controls, engine...

  16. 14 CFR 25.865 - Fire protection of flight controls, engine mounts, and other flight structure.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Design and Construction Fire Protection § 25.865 Fire protection of flight controls, engine mounts, and other flight structure. Essential flight controls, engine mounts, and other flight structures located in... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fire protection of flight controls, engine...

  17. 14 CFR 25.865 - Fire protection of flight controls, engine mounts, and other flight structure.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Design and Construction Fire Protection § 25.865 Fire protection of flight controls, engine mounts, and other flight structure. Essential flight controls, engine mounts, and other flight structures located in... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire protection of flight controls, engine...

  18. 14 CFR 25.865 - Fire protection of flight controls, engine mounts, and other flight structure.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Design and Construction Fire Protection § 25.865 Fire protection of flight controls, engine mounts, and other flight structure. Essential flight controls, engine mounts, and other flight structures located in... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fire protection of flight controls, engine...

  19. 14 CFR 25.865 - Fire protection of flight controls, engine mounts, and other flight structure.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Design and Construction Fire Protection § 25.865 Fire protection of flight controls, engine mounts, and other flight structure. Essential flight controls, engine mounts, and other flight structures located in... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fire protection of flight controls, engine...

  20. 14 CFR 29.1359 - Electrical system fire and smoke protection.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Electrical system fire and smoke protection... Equipment § 29.1359 Electrical system fire and smoke protection. (a) Components of the electrical system must meet the applicable fire and smoke protection provisions of §§ 29.831 and 29.863. (b) Electrical...

  1. 14 CFR 29.1359 - Electrical system fire and smoke protection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Electrical system fire and smoke protection... Equipment § 29.1359 Electrical system fire and smoke protection. (a) Components of the electrical system must meet the applicable fire and smoke protection provisions of §§ 29.831 and 29.863. (b) Electrical...

  2. 14 CFR 29.1359 - Electrical system fire and smoke protection.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Electrical system fire and smoke protection... Equipment § 29.1359 Electrical system fire and smoke protection. (a) Components of the electrical system must meet the applicable fire and smoke protection provisions of §§ 29.831 and 29.863. (b) Electrical...

  3. 14 CFR 29.1359 - Electrical system fire and smoke protection.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Electrical system fire and smoke protection... Equipment § 29.1359 Electrical system fire and smoke protection. (a) Components of the electrical system must meet the applicable fire and smoke protection provisions of §§ 29.831 and 29.863. (b) Electrical...

  4. 14 CFR 23.1359 - Electrical system fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Electrical system fire protection. 23.1359... Electrical Systems and Equipment § 23.1359 Electrical system fire protection. (a) Each component of the electrical system must meet the applicable fire protection requirements of §§ 23.863 and 23.1182. (b...

  5. 14 CFR 23.1359 - Electrical system fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Electrical system fire protection. 23.1359... Electrical Systems and Equipment § 23.1359 Electrical system fire protection. (a) Each component of the electrical system must meet the applicable fire protection requirements of §§ 23.863 and 23.1182. (b...

  6. 14 CFR 23.1359 - Electrical system fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Electrical system fire protection. 23.1359... Electrical Systems and Equipment § 23.1359 Electrical system fire protection. (a) Each component of the electrical system must meet the applicable fire protection requirements of §§ 23.863 and 23.1182. (b...

  7. 14 CFR 23.1359 - Electrical system fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Electrical system fire protection. 23.1359... Electrical Systems and Equipment § 23.1359 Electrical system fire protection. (a) Each component of the electrical system must meet the applicable fire protection requirements of §§ 23.863 and 23.1182. (b...

  8. 14 CFR 23.1359 - Electrical system fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Electrical system fire protection. 23.1359... Electrical Systems and Equipment § 23.1359 Electrical system fire protection. (a) Each component of the electrical system must meet the applicable fire protection requirements of §§ 23.863 and 23.1182. (b...

  9. 36 CFR 1234.12 - What are the fire safety requirements that apply to records storage facilities?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... records storage facilities? (a) The fire detection and protection systems must be designed or reviewed by a licensed fire protection engineer. If the system was not designed by a licensed fire protection... engineer that describes the design intent of the fire detection and suppression system, detailing the...

  10. 36 CFR 1234.12 - What are the fire safety requirements that apply to records storage facilities?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... records storage facilities? (a) The fire detection and protection systems must be designed or reviewed by a licensed fire protection engineer. If the system was not designed by a licensed fire protection... engineer that describes the design intent of the fire detection and suppression system, detailing the...

  11. 49 CFR 178.338-1 - General requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... outer shell or jacket, with insulation between the inner vessel and outer shell or jacket, and having... specification, tank means inner vessel and jacket means either the outer shell or insulation cover. (c) Each.... (1) Each cargo tank must have an insulation system that will prevent the tank pressure from exceeding...

  12. 49 CFR 178.338-1 - General requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... outer shell or jacket, with insulation between the inner vessel and outer shell or jacket, and having... specification, tank means inner vessel and jacket means either the outer shell or insulation cover. (c) Each.... (1) Each cargo tank must have an insulation system that will prevent the tank pressure from exceeding...

  13. 49 CFR 178.338-1 - General requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... outer shell or jacket, with insulation between the inner vessel and outer shell or jacket, and having... specification, tank means inner vessel and jacket means either the outer shell or insulation cover. (c) Each.... (1) Each cargo tank must have an insulation system that will prevent the tank pressure from exceeding...

  14. JACKETED FUEL ELEMENTS FOR GRAPHITE MODERATED REACTORS

    DOEpatents

    Szilard, L.; Wigner, E.P.; Creutz, E.C.

    1959-05-12

    Fuel elements for a heterogeneous, fluid cooled, graphite moderated reactor are described. The fuel elements are comprised of a body of natural uranium hermetically sealed in a jacket of corrosion resistant material. The jacket, which may be aluminum or some other material which is non-fissionable and of a type having a low neutron capture cross-section, acts as a barrier between the fissioning isotope and the coolant or moderator or both. The jacket minimizes the tendency of the moderator and coolant to become radioactive and/or contaminated by fission fragments from the fissioning isotope.

  15. Infrared detector Dewars - Increased LN2 hold time and vacuum jacket life spans

    NASA Technical Reports Server (NTRS)

    Jennings, D. E.; Boyd, W. J.; Blass, W. E.

    1976-01-01

    IR detector Dewars commonly suffer from shorter than desired LN2 hold times and insulation jacket vacuum corruption over relatively short time periods. In an attempt to solve this problem for a 9144 detector Dewar, small 1 liter/s appendage ion pumps were selected for continuous pumping of the vacuum jackets. This procedure extended LN2 hold times from 20 to 60 h and virtually eliminated vacuum jacket corruption. Thus the detector systems are usable continuously over periods of 6 months or more.

  16. Fire Hazard Assessment in Supporting Fire Protection System Design of a Chemical Process Facility

    DTIC Science & Technology

    1996-08-01

    CSDP/Studies/FireHaz –i– 3/28/97 FIRE HAZARD ASSESSMENT IN SUPPORTING FIRE PROTECTION SYSTEM DESIGN OF A CHEMICAL PROCESS FACILITY Ali Pezeshk...Joseph Chang, Dwight Hunt, and Peter Jahn Parsons Infrastructure & Technology Group, Inc. Pasadena, California 91124 ABSTRACT Because fires in a chemical ...Assessment in Supporting Fire Protection System Design of a Chemical Process Facility 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6

  17. Fire Protection Specialist, Blocks I, II, & III, 17-2. Military Curriculum Materials for Vocational and Technical Education.

    ERIC Educational Resources Information Center

    Ohio State Univ., Columbus. National Center for Research in Vocational Education.

    This military-developed text contains the first three blocks of a five-block course for use in training fire protection specialists. Covered in the individual volumes are the following topics: fire protection objectives and responsibilities (fire protection and occupational safety, extinguishing agents, principles and theory of combustion, natural…

  18. Wounding capacity of muzzle-gas pressure.

    PubMed

    Schyma, Christian

    2012-05-01

    Suicidal gunshot wounds that are caused by ammunition fired from a 9-mm Luger pistol, with direct contact between the gun muzzle and the victim's head, present a serious injury pattern even with full metal jacket bullets. Wound ballistic experiments were performed to clarify whether muzzle gases from the firearm have an additional wounding potential. Fifteen head models were prepared as follows: an acryl sphere measuring 14 cm in diameter was completely covered with a layer of silicon that was 3 mm thick. These spheres were filled with 10% gelatine. At 4°C, these models were fired at with a 9-mm Luger pistol, loaded with Quick Defense 1 expanding bullets. Five shots were fired with direct muzzle contact, one shot was fired from a distance of 10 cm, four shots were fired from a distance of 2 m, and five shots were fired from a distance of 4 m. Each projectile penetrated the model; all but one projectile deformed regularly. Each acryl sphere shattered into comminuted pieces but was held together by the silicon cover. The gelatine filling was then cut into slices 1 cm thick, and each slice was optically scanned. An evaluation was performed following both Fackler's Wound Profile method and the polygon procedure method. The pattern of gelatine disruption did not differ in shots from intermediate ranges, but the amount of gelatine destruction was always more extended in the case of muzzle contact shots. Depending on the section of the bullet path, crack lengths were 31% to 133% longer in contact shots. The first centimetre and the second half of the bullet path showed the greatest increase. The experimental findings prove the wounding capacity of muzzle gases.

  19. Forest Fire Occurrence in Southern Counties, 1966-1975

    Treesearch

    M.L. Doolittle

    1977-01-01

    Forest fire occurrence data for individual protection units generally are unavailable outside particular state organization. Number of fires, area protected and fire occurrence rate (fires per 1,000,000 acres) from 1966 to 1975, are presented in tables for the 993 counties under protection in 13 southern states. These data are compared with data for the preceeding...

  20. 36 CFR § 1234.12 - What are the fire safety requirements that apply to records storage facilities?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... records storage facilities? (a) The fire detection and protection systems must be designed or reviewed by a licensed fire protection engineer. If the system was not designed by a licensed fire protection... engineer that describes the design intent of the fire detection and suppression system, detailing the...

  1. Nano-silica as the go material on heat resistant tunnel lining

    NASA Astrophysics Data System (ADS)

    Omar, Faizah; Osman, S. A.; Mutalib, A.

    2018-04-01

    This paper is concerned with passive fire protection method of protective concrete mix that is made up of fly ash, polypropylene fibre, and nano-silica. Nano-silica is focused on as the innovative material to be used in the composition of the protective concrete mix. The previous experimental studies which analyse the performance of passive fire protection on tunnels are discussed. This paper also discusses passive fire protection. The fire protection materials and behaviour analyses of tunnel structure are also presented. At the end of the paper, the recommendation of the optimum composition concrete material with fly ash, polypropylene fibre and nano-silica as tunnel lining fire protective materials is proposed.

  2. 76 FR 49453 - CVS Pharmacy, Inc., Provisional Acceptance of a Settlement Agreement and Order

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-10

    ...; telephone (301) 504-7612. SUPPLEMENTARY INFORMATION: The text of the Agreement and Order appears below... hooded fleece jackets with drawstrings at the neck (``Jackets''). 5. CVS sold the Jackets, and/or held... (``Guidelines'') to help prevent children from strangling or entangling on neck and waist drawstrings. The...

  3. 49 CFR 173.318 - Cryogenic liquids in cargo tanks.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ....338-15). (3) The jacket covering the insulation on a tank used to transport a cryogenic liquid must be... devices for piping hose and vacuum-insulated jackets. (i) Each portion of connected liquid piping or hose... tank, piping, or operating personnel. (ii) On a vacuum-insulated cargo tank the jacket must be...

  4. THE MAN&RSQUO;S JACKET DESIGN FOR DISASSEMBLY: AN IMPLEMENTATION OF C2CAD FRAMEWORK

    EPA Science Inventory

    The C2CAD model served as the basis in the man’s jacket design and production. In man’s jackets, both natural and synthetic materials are commonly used for fabrics, threads, and buttons. To promote disassembly and value retention, we minimized material diversity an...

  5. 46 CFR 117.72 - Personal flotation devices carried in addition to life jackets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Personal flotation devices carried in addition to life jackets. 117.72 Section 117.72 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL... approved life jackets required to be worn during drills and emergencies. (b) Wearable marine buoyant...

  6. 46 CFR 117.72 - Personal flotation devices carried in addition to life jackets.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Personal flotation devices carried in addition to life jackets. 117.72 Section 117.72 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL... approved life jackets required to be worn during drills and emergencies. (b) Wearable marine buoyant...

  7. 46 CFR 122.730 - Servicing of inflatable liferafts, inflatable buoyant apparatus, inflatable life jackets, and...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... apparatus, inflatable life jackets, and inflated rescue boats. 122.730 Section 122.730 Shipping COAST GUARD..., inflatable life jackets, and inflated rescue boats. (a) An inflatable liferaft or inflatable buoyant... other standard specified by the Commandant. (e) Repair and maintenance of inflated rescue boats must be...

  8. 46 CFR 185.730 - Servicing of inflatable liferafts, inflatable buoyant apparatus, inflatable life jackets, and...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... apparatus, inflatable life jackets, and inflated rescue boats. 185.730 Section 185.730 Shipping COAST GUARD... liferafts, inflatable buoyant apparatus, inflatable life jackets, and inflated rescue boats. (a) An... inflated rescue boats must be in accordance with the manufacturer's instructions. All repairs must be made...

  9. 46 CFR 122.730 - Servicing of inflatable liferafts, inflatable buoyant apparatus, inflatable life jackets, and...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... apparatus, inflatable life jackets, and inflated rescue boats. 122.730 Section 122.730 Shipping COAST GUARD..., inflatable life jackets, and inflated rescue boats. (a) An inflatable liferaft or inflatable buoyant... other standard specified by the Commandant. (e) Repair and maintenance of inflated rescue boats must be...

  10. 46 CFR 185.730 - Servicing of inflatable liferafts, inflatable buoyant apparatus, inflatable life jackets, and...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... apparatus, inflatable life jackets, and inflated rescue boats. 185.730 Section 185.730 Shipping COAST GUARD... liferafts, inflatable buoyant apparatus, inflatable life jackets, and inflated rescue boats. (a) An... inflated rescue boats must be in accordance with the manufacturer's instructions. All repairs must be made...

  11. 46 CFR 122.730 - Servicing of inflatable liferafts, inflatable buoyant apparatus, inflatable life jackets, and...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... apparatus, inflatable life jackets, and inflated rescue boats. 122.730 Section 122.730 Shipping COAST GUARD..., inflatable life jackets, and inflated rescue boats. (a) An inflatable liferaft or inflatable buoyant... other standard specified by the Commandant. (e) Repair and maintenance of inflated rescue boats must be...

  12. 46 CFR 185.730 - Servicing of inflatable liferafts, inflatable buoyant apparatus, inflatable life jackets, and...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... apparatus, inflatable life jackets, and inflated rescue boats. 185.730 Section 185.730 Shipping COAST GUARD... liferafts, inflatable buoyant apparatus, inflatable life jackets, and inflated rescue boats. (a) An... inflated rescue boats must be in accordance with the manufacturer's instructions. All repairs must be made...

  13. Maintenance Facilities for Ammunition, Explosives, and Toxics. Design Manual 28.3.

    DTIC Science & Technology

    1981-11-01

    LOADING DOCK RAMP PROTECTION 28.3-2 8. FIRE PROTECTION 28.3-2 9. SECURITY 28.3-2 10. SAFETY 28.3-2 Section 2. GENERAL AMMUNITION MAINTENANCE SHOPS 28.3...protection in accordance with Section 3 1910.23c, Occupatioual Safety and Health Act Standards Manual. 5 8. FIRE PROTECTION. Fire protection for all...Volume 1, and Fire Protection Engineering, NAVFAC DM-8. 9. SECURITY. Maintenance facilities for ammunition, explosives, and I toxics shall be located so

  14. JACKETED FUEL ELEMENT

    DOEpatents

    Wigner, E.P.; Szilard, L.; Creutz, E.C.

    1959-02-01

    These fuel elements are comprised of a homogeneous metallic uranium body completely enclosed and sealed in an aluminum cover. The uranium body and aluminum cover are bonded together by a layer of zinc located between them. The bonding layer serves to improve transfer of heat, provides an additional protection against corrosion of the uranium by the coolant, and also localizes any possible corrosion by preventing travel of corrosive material along the surface of the fuel element.

  15. Design and fabrication of the 20 km/10 kV electromechanical tether for TSS-1 using high impact conductor (Hiwire)

    NASA Technical Reports Server (NTRS)

    Scala, E.; Bentley, D. P.; Marshall, L. S.

    1986-01-01

    The development of a 20-km electromechanical tether for the tethered satellite system (TSS) is described. The basic design requirements for electromagnetic cables and for conductors in cables subject to stresses and cyclic loading are discussed. The tether fabricatioon procedures involve: (1) conductor twisting around the core, (2) insulation extrusion, (3) strength member braiding, and (4) protective jacket braiding.

  16. 29 CFR Appendix A to Subpart L of... - Fire Protection

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the International Fire Service Training Association, the National Fire Protection Association (NFPA-1041), the International Society of Fire Service Instructors and other fire training sources be... planning, and safety practices. It is again suggested that fire service training sources be consulted for...

  17. 78 FR 58967 - Airworthiness Directives; ATR-GIE Avions de Transport Régional Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-25

    ... extinction and allow fire propagation out of the nacelle fire protected area, resulting in damage to the... efficiency, delay the fire extinction and allow fire propagation out of the nacelle fire protected area... the decrease of the fire extinguishing agent efficiency, which could delay fire extinction and allow...

  18. Stochastic representation of fire behavior in a wildland fire protection planning model for California.

    Treesearch

    J. Keith Gilless; Jeremy S. Fried

    1998-01-01

    A fire behavior module was developed for the California Fire Economics Simulator version 2 (CFES2), a stochastic simulation model of initial attack on wildland fire used by the California Department of Forestry and Fire Protection. Fire rate of spread (ROS) and fire dispatch level (FDL) for simulated fires "occurring" on the same day are determined by making...

  19. 76 FR 29011 - Agency Information Collection Activities; Submission for OMB Review; Comment Request; Fire...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-19

    ... for OMB Review; Comment Request; Fire Protection in Shipyard Employment ACTION: Notice. SUMMARY: The... information collection request (ICR) titled, ``Fire Protection in Shipyard Employment,'' to the Office of... Fire Protection in Shipyard Employment Standard makes it mandatory for a covered employer to develop a...

  20. 14 CFR 29.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Combustion heater fire protection. 29.859... § 29.859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... any ventilating air passage that— (i) Surrounds the combustion chamber; and (ii) Would not contain...

  1. 14 CFR 29.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Combustion heater fire protection. 29.859... § 29.859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... any ventilating air passage that— (i) Surrounds the combustion chamber; and (ii) Would not contain...

  2. 14 CFR 29.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Combustion heater fire protection. 29.859... § 29.859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... any ventilating air passage that— (i) Surrounds the combustion chamber; and (ii) Would not contain...

  3. 14 CFR 29.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Combustion heater fire protection. 29.859... § 29.859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... any ventilating air passage that— (i) Surrounds the combustion chamber; and (ii) Would not contain...

  4. 14 CFR 29.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Combustion heater fire protection. 29.859... § 29.859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... any ventilating air passage that— (i) Surrounds the combustion chamber; and (ii) Would not contain...

  5. 46 CFR 161.002-1 - Incorporation by reference.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Amendments to SOLAS 74), 1992—161.002-4(b). National Fire Protection Association (NFPA) National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269. NFPA 72, National Fire Alarm Code, 1993—161...: SPECIFICATIONS AND APPROVAL ELECTRICAL EQUIPMENT Fire-Protective Systems § 161.002-1 Incorporation by reference...

  6. 46 CFR 161.002-1 - Incorporation by reference.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Amendments to SOLAS 74), 1992—161.002-4(b). National Fire Protection Association (NFPA) National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269. NFPA 72, National Fire Alarm Code, 1993—161...: SPECIFICATIONS AND APPROVAL ELECTRICAL EQUIPMENT Fire-Protective Systems § 161.002-1 Incorporation by reference...

  7. 49 CFR 193.2717 - Training: fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... under § 193.2801. (b) A written plan of continuing instruction, including plant fire drills, must be... 49 Transportation 3 2013-10-01 2013-10-01 false Training: fire protection. 193.2717 Section 193...: fire protection. (a) All personnel involved in maintenance and operations of an LNG plant, including...

  8. 49 CFR 193.2717 - Training: fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... under § 193.2801. (b) A written plan of continuing instruction, including plant fire drills, must be... 49 Transportation 3 2011-10-01 2011-10-01 false Training: fire protection. 193.2717 Section 193...: fire protection. (a) All personnel involved in maintenance and operations of an LNG plant, including...

  9. 49 CFR 193.2717 - Training: fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... under § 193.2801. (b) A written plan of continuing instruction, including plant fire drills, must be... 49 Transportation 3 2012-10-01 2012-10-01 false Training: fire protection. 193.2717 Section 193...: fire protection. (a) All personnel involved in maintenance and operations of an LNG plant, including...

  10. 49 CFR 193.2717 - Training: fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... under § 193.2801. (b) A written plan of continuing instruction, including plant fire drills, must be... 49 Transportation 3 2014-10-01 2014-10-01 false Training: fire protection. 193.2717 Section 193...: fire protection. (a) All personnel involved in maintenance and operations of an LNG plant, including...

  11. 48 CFR 2052.235-71 - Safety, health, and fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ....235-71 Safety, health, and fire protection. As prescribed in 2035.70(a)(2), the contracting officer... 48 Federal Acquisition Regulations System 6 2014-10-01 2014-10-01 false Safety, health, and fire..., Health, and Fire Protection (JAN 1993) The contractor shall take all reasonable precautions in the...

  12. 48 CFR 2052.235-71 - Safety, health, and fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ....235-71 Safety, health, and fire protection. As prescribed in 2035.70(a)(2), the contracting officer... 48 Federal Acquisition Regulations System 6 2012-10-01 2012-10-01 false Safety, health, and fire..., Health, and Fire Protection (JAN 1993) The contractor shall take all reasonable precautions in the...

  13. 48 CFR 2052.235-71 - Safety, health, and fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ....235-71 Safety, health, and fire protection. As prescribed in 2035.70(a)(2), the contracting officer... 48 Federal Acquisition Regulations System 6 2013-10-01 2013-10-01 false Safety, health, and fire..., Health, and Fire Protection (JAN 1993) The contractor shall take all reasonable precautions in the...

  14. 48 CFR 2052.235-71 - Safety, health, and fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ....235-71 Safety, health, and fire protection. As prescribed in 2035.70(a)(2), the contracting officer... 48 Federal Acquisition Regulations System 6 2011-10-01 2011-10-01 false Safety, health, and fire..., Health, and Fire Protection (JAN 1993) The contractor shall take all reasonable precautions in the...

  15. 7 CFR 1755.902 - Minimum performance Specification for fiber optic cables.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... such a way as to form a cylindrical group. (2) The standard cylindrical group or core designs commonly consist of 4, 6, 12, 18, or 24 fibers. Cylindrical groups or core designs larger than the sizes shown...) Inner jackets. (1) For designs with more than one jacket, the inner jackets must be applied directly...

  16. 7 CFR 1755.902 - Minimum performance Specification for fiber optic cables.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... such a way as to form a cylindrical group. (2) The standard cylindrical group or core designs commonly consist of 4, 6, 12, 18, or 24 fibers. Cylindrical groups or core designs larger than the sizes shown...) Inner jackets. (1) For designs with more than one jacket, the inner jackets must be applied directly...

  17. 7 CFR 1755.902 - Minimum performance Specification for fiber optic cables.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... such a way as to form a cylindrical group. (2) The standard cylindrical group or core designs commonly consist of 4, 6, 12, 18, or 24 fibers. Cylindrical groups or core designs larger than the sizes shown...) Inner jackets. (1) For designs with more than one jacket, the inner jackets must be applied directly...

  18. 7 CFR 1755.902 - Minimum performance Specification for fiber optic cables.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... such a way as to form a cylindrical group. (2) The standard cylindrical group or core designs commonly consist of 4, 6, 12, 18, or 24 fibers. Cylindrical groups or core designs larger than the sizes shown...) Inner jackets. (1) For designs with more than one jacket, the inner jackets must be applied directly...

  19. 7 CFR 1755.902 - Minimum performance Specification for fiber optic cables.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... such a way as to form a cylindrical group. (2) The standard cylindrical group or core designs commonly consist of 4, 6, 12, 18, or 24 fibers. Cylindrical groups or core designs larger than the sizes shown...) Inner jackets. (1) For designs with more than one jacket, the inner jackets must be applied directly...

  20. H∞ memory feedback control with input limitation minimization for offshore jacket platform stabilization

    NASA Astrophysics Data System (ADS)

    Yang, Jia Sheng

    2018-06-01

    In this paper, we investigate a H∞ memory controller with input limitation minimization (HMCIM) for offshore jacket platforms stabilization. The main objective of this study is to reduce the control consumption as well as protect the actuator when satisfying the requirement of the system performance. First, we introduce a dynamic model of offshore platform with low order main modes based on mode reduction method in numerical analysis. Then, based on H∞ control theory and matrix inequality techniques, we develop a novel H∞ memory controller with input limitation. Furthermore, a non-convex optimization model to minimize input energy consumption is proposed. Since it is difficult to solve this non-convex optimization model by optimization algorithm, we use a relaxation method with matrix operations to transform this non-convex optimization model to be a convex optimization model. Thus, it could be solved by a standard convex optimization solver in MATLAB or CPLEX. Finally, several numerical examples are given to validate the proposed models and methods.

  1. Differences in the element contents between gunshot entry wounds with full-jacketed bullet and lead bullet.

    PubMed

    Wunnapuk, Klintean; Durongkadech, Piya; Minami, Takeshi; Ruangyuttikarn, Werawan; Tohno, Setsuko; Vichairat, Karnda; Azuma, Cho; Sribanditmongkol, Pongruk; Tohno, Yoshiyuki

    2007-01-01

    To elucidate characteristics of gunshot residues in gunshot entry wounds with full-jacketed and lead bullets, element contents in entry gunshot wounds and control skins were analyzed by inductively coupled plasma-atomic emission spectrometry (ICP-AES). It was found that a high content of Fe and Zn was deposited in the gunshot entry wounds with full-jacketed bullet, whereas a high content of Pb was deposited in the gunshot entry wounds with lead (unjacked) bullet. It should be noted that the content of Pb was significantly higher in the gunshot entry wounds with lead bullet than in those with full-jacketed bullet. Regarding the relationships among elements, it was found that there were significant direct correlations between Pb and either Sb or Ba contents in both gunshot entry wounds with full-jacketed and lead bullets. As Pb increased in both gunshot entry wounds, Sb and Ba also increased in the wounds.

  2. Yellow jackets may be an underestimated component of an ant-seed mutualism

    USGS Publications Warehouse

    Bale, M.T.; Zettler, J.A.; Robinson, B.A.; Spira, T.P.; Allen, Craig R.

    2003-01-01

    Yellow jackets (Hymenoptera: Vespidae) are attracted to the typically ant-dispersed seeds of trilliums and will take seeds from ants in the genus Aphaenogaster. To determine if yellow jacket, Vespula maculifrons (Buysson), presence interferes with seed foraging by ants, we presented seeds of Trillium discolor Wray to three species (A. texana carolinensis Wheeler, Formica schaufussi Mayr, and Solenopsis invicta Buren) of seed-carrying ants in areas where vespids were present or excluded. We found that interspecific aggression between yellow jackets and ants is species specific. Vespid presence decreased average foraging time and increased foraging efficiency of two of the three ant species studied, a situation that might reflect competition for a limited food source. We also found that yellow jackets removed more seeds than ants, suggestive that vespids are important, albeit underestimated, components of ant-seed mutualisms.

  3. Fire protection for a Martian colony

    NASA Astrophysics Data System (ADS)

    Beattie, Robert M., Jr.

    The fire prevention failures that occurred in Apollo 1 and Challenger accidents are reviewed and used to discuss fire protection measures that should be taken in a Martian colony. Fire detection systems, classes of fire, and suppression agents are described. The organization of fire fighting personnel appropriate for Mars is addressed.

  4. Fire Protection for Rural Communities.

    ERIC Educational Resources Information Center

    Hagevig, William A.

    Fire protection in rural Alaskan communities depends on individual home fire prevention and protection rather than on the services offered by a centralized fire department. Even when help is summoned to extinguish a blaze, aid does not come in the form of a cadre of highly trained firefighters; it comes instead from whomever happens to be in the…

  5. 76 FR 70414 - National Fire Protection Association (NFPA) Proposes To Revise Codes and Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-14

    ... DEPARTMENT OF COMMERCE National Institute of Standards and Technology National Fire Protection... publishing this notice on behalf of the National Fire Protection Association (NFPA) to announce the NFPA's proposal to revise some of its fire safety codes and standards and requests proposals from the public to...

  6. 14 CFR 23.1451 - Fire protection for oxygen equipment.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fire protection for oxygen equipment. 23... Equipment Miscellaneous Equipment § 23.1451 Fire protection for oxygen equipment. Oxygen equipment and lines... in, or escape from, any designated fire zone. (c) Be installed so that escaping oxygen cannot come in...

  7. 14 CFR 23.1451 - Fire protection for oxygen equipment.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fire protection for oxygen equipment. 23... Equipment Miscellaneous Equipment § 23.1451 Fire protection for oxygen equipment. Oxygen equipment and lines... in, or escape from, any designated fire zone. (c) Be installed so that escaping oxygen cannot come in...

  8. 14 CFR 23.1451 - Fire protection for oxygen equipment.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fire protection for oxygen equipment. 23... Equipment Miscellaneous Equipment § 23.1451 Fire protection for oxygen equipment. Oxygen equipment and lines... in, or escape from, any designated fire zone. (c) Be installed so that escaping oxygen cannot come in...

  9. 14 CFR 23.1451 - Fire protection for oxygen equipment.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire protection for oxygen equipment. 23... Equipment Miscellaneous Equipment § 23.1451 Fire protection for oxygen equipment. Oxygen equipment and lines... in, or escape from, any designated fire zone. (c) Be installed so that escaping oxygen cannot come in...

  10. 14 CFR 23.1451 - Fire protection for oxygen equipment.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fire protection for oxygen equipment. 23... Equipment Miscellaneous Equipment § 23.1451 Fire protection for oxygen equipment. Oxygen equipment and lines... in, or escape from, any designated fire zone. (c) Be installed so that escaping oxygen cannot come in...

  11. 10 CFR 36.27 - Fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Fire protection. 36.27 Section 36.27 Energy NUCLEAR... Requirements for Irradiators § 36.27 Fire protection. (a) The radiation room at a panoramic irradiator must... become fully shielded if a fire is detected. (b) The radiation room at a panoramic irradiator must be...

  12. 33 CFR 149.641 - What are the structural fire protection requirements for accommodation spaces and modules?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false What are the structural fire...: DESIGN, CONSTRUCTION, AND EQUIPMENT Design and Equipment Structural Fire Protection § 149.641 What are the structural fire protection requirements for accommodation spaces and modules? (a) Accommodation...

  13. 33 CFR 149.641 - What are the structural fire protection requirements for accommodation spaces and modules?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false What are the structural fire...: DESIGN, CONSTRUCTION, AND EQUIPMENT Design and Equipment Structural Fire Protection § 149.641 What are the structural fire protection requirements for accommodation spaces and modules? (a) Accommodation...

  14. Application of Graph Theory to Cost-Effective Fire Protection of Chemical Plants During Domino Effects.

    PubMed

    Khakzad, Nima; Landucci, Gabriele; Reniers, Genserik

    2017-09-01

    In the present study, we have introduced a methodology based on graph theory and multicriteria decision analysis for cost-effective fire protection of chemical plants subject to fire-induced domino effects. By modeling domino effects in chemical plants as a directed graph, the graph centrality measures such as out-closeness and betweenness scores can be used to identify the installations playing a key role in initiating and propagating potential domino effects. It is demonstrated that active fire protection of installations with the highest out-closeness score and passive fire protection of installations with the highest betweenness score are the most effective strategies for reducing the vulnerability of chemical plants to fire-induced domino effects. We have employed a dynamic graph analysis to investigate the impact of both the availability and the degradation of fire protection measures over time on the vulnerability of chemical plants. The results obtained from the graph analysis can further be prioritized using multicriteria decision analysis techniques such as the method of reference point to find the most cost-effective fire protection strategy. © 2016 Society for Risk Analysis.

  15. 33 CFR 149.419 - Can the water supply for the helicopter deck fire protection system be part of a fire water system?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Can the water supply for the... § 149.419 Can the water supply for the helicopter deck fire protection system be part of a fire water system? (a) The water supply for the helicopter deck fire protection system required under § 149.420 or...

  16. External heating of electrical cables and auto-ignition investigation.

    PubMed

    Courty, L; Garo, J P

    2017-01-05

    Electric cables are now extensively used for both residential and industrial applications. During more than twenty years, multi-scale approaches have been developed to study fire behavior of such cables that represents a serious challenge. Cables are rather complicated materials because they consist of an insulated part and jacket of polymeric materials. These polymeric materials can have various chemical structures, thicknesses and additives and generally have a char-forming tendency when exposed to heat source. In this work, two test methods are used for the characterization of cable pyrolysis and flammability. The first one permits the investigation of cable pyrolysis. A description of the cable mass loss is obtained, coupling an Arrhenius expression with a 1D thermal model of cables heating. Numerical results are successfully compared with experimental data obtained for two types of cable commonly used in French nuclear power plants. The second one is devoted to ignition investigations (spontaneous or piloted) of these cables. All these basic observations, measurements and modelling efforts are of major interest for a more comprehensive fire resistance evaluation of electric cables. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. 49 CFR 173.314 - Compressed gases in tank cars and multi-unit tank cars.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... shield as prescribed in § 179.16(c)(1). (d) Alternative tank car tanks for materials poisonous by... the alternative tank car jacket and head shield. When the jacket and head shield are made from any...., the thickness to be added to the jacket and head shield must be increased by a factor of 1.157...

  18. 49 CFR 173.314 - Compressed gases in tank cars and multi-unit tank cars.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... applicable authorized tank car specification and must be equipped with a head shield as prescribed in § 179... jacket and head shield. When the jacket and head shield are made from any authorized steel with a minimum... jacket and head shield must be increased by a factor of 1.157. Forming allowances for heads are not...

  19. 49 CFR 173.314 - Compressed gases in tank cars and multi-unit tank cars.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... applicable authorized tank car specification and must be equipped with a head shield as prescribed in § 179... jacket and head shield. When the jacket and head shield are made from any authorized steel with a minimum... jacket and head shield must be increased by a factor of 1.157. Forming allowances for heads are not...

  20. 49 CFR 179.400-9 - Stiffening rings.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... stiffening ring is given by the following formula: W = 0.78(Rt)0.5 Where: W = width of jacket effective on... consists of a closed section having two webs attached to the outer jacket, the jacket plate between the webs may be included up to the limit of twice the value of “W”, as defined in paragraph (b) of this...

  1. Lightweight Vacuum Jacket for Cryogenic Insulation. Volume 1

    NASA Technical Reports Server (NTRS)

    Barclay, D. L.; Bell, J. E.; Brogren, E. W.; Straayer, J. W.

    1975-01-01

    The feasibility of producing a lightweight vacuum jacket using state-of-the-art technology and materials was examined. Design and analytical studies were made on a full-scale, orbital maneuvering system fuel tank. Preliminary design details were made for the tank assembly, including an optimized vacuum jacket and multilayer insulation system. A half-scale LH2 test model was designed and fabricated, and a force/stiffness proof test was conducted on the vacuum jacket. A vacuum leak rate of .000001 atmosphere ml of helium per second was measured, approximately 1500 hours of vacuum pressure were sustained, and 29 vacuum-pressure cycles were experienced prior to failure.

  2. Lightweight Vacuum Jacket for Cryogenic Insulation - Appendices to Final Report. Volume 2

    NASA Technical Reports Server (NTRS)

    Barclay, D. L.; Bell, J. E.; Brogren, E. W.; Straayer, J. W.

    1975-01-01

    The feasibility is demonstrated of producing a lightweight vacuum jacket using state-of-the-art technology and materials. Design and analytical studies were made on an orbital maneuvering system fuel tank. Preliminary design details were completed for the tank assembly which included an optimized vacuum jacket and multilayered insulation system. A half-scale LH2 test model was designed and fabricated and a force/stiffness proof test was conducted on the vacuum jacket. A vacuum leak rate of 0.00001 was measured, approximately 1500 hours of vacuum pressure was sustained, and 29 vacuum pressure cycles were experienced prior to failure. For vol. 1, see N75-26192.

  3. Water cooled steam jet

    DOEpatents

    Wagner, Jr., Edward P.

    1999-01-01

    A water cooled steam jet for transferring fluid and preventing vapor lock, or vaporization of the fluid being transferred, has a venturi nozzle and a cooling jacket. The venturi nozzle produces a high velocity flow which creates a vacuum to draw fluid from a source of fluid. The venturi nozzle has a converging section connected to a source of steam, a diffuser section attached to an outlet and a throat portion disposed therebetween. The cooling jacket surrounds the venturi nozzle and a suction tube through which the fluid is being drawn into the venturi nozzle. Coolant flows through the cooling jacket. The cooling jacket dissipates heat generated by the venturi nozzle to prevent vapor lock.

  4. Protecting the Library and Its Resources. A Guide to Physical Protection and Insurance.

    ERIC Educational Resources Information Center

    Johnson, Edward M., Ed.

    The first part of this manual contains information about providing physical protection for libraries and is organized into the following chapters--(1) types of physical losses, (2) the prevention of losses, (3) fire defense measures, (4) fire protection equipment, and (5) fire protection in library planning. The second part is concerned with…

  5. 46 CFR 181.320 - Fire hoses and nozzles.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Fire hoses and nozzles. 181.320 Section 181.320 Shipping...) FIRE PROTECTION EQUIPMENT Fire Main System § 181.320 Fire hoses and nozzles. (a) A fire hose with a... cargo decks, where no protection is provided, hoses may be temporarily removed during heavy weather or...

  6. 46 CFR 181.320 - Fire hoses and nozzles.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Fire hoses and nozzles. 181.320 Section 181.320 Shipping...) FIRE PROTECTION EQUIPMENT Fire Main System § 181.320 Fire hoses and nozzles. (a) A fire hose with a... cargo decks, where no protection is provided, hoses may be temporarily removed during heavy weather or...

  7. 46 CFR 181.320 - Fire hoses and nozzles.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Fire hoses and nozzles. 181.320 Section 181.320 Shipping...) FIRE PROTECTION EQUIPMENT Fire Main System § 181.320 Fire hoses and nozzles. (a) A fire hose with a... cargo decks, where no protection is provided, hoses may be temporarily removed during heavy weather or...

  8. 46 CFR 181.320 - Fire hoses and nozzles.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Fire hoses and nozzles. 181.320 Section 181.320 Shipping...) FIRE PROTECTION EQUIPMENT Fire Main System § 181.320 Fire hoses and nozzles. (a) A fire hose with a... cargo decks, where no protection is provided, hoses may be temporarily removed during heavy weather or...

  9. Acquisition of Ice-Tethered Profilers with Velocity (ITP-V) Instruments for Future Arctic Studies

    DTIC Science & Technology

    2015-09-30

    jacketed wire rope tether and end weight should the ice fracture or melt , and to provide modest protection in the event of ice ridging. The profiler...1 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Acquisition of Ice -Tethered Profilers with Velocity (ITP...evolving thermohaline stratification, the ocean currents and air- ice -sea interactions on time scales of minutes to seasonal and longer. OBJECTIVES

  10. 41 CFR 102-80.135 - Who is a qualified fire protection engineer?

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... protection engineer? 102-80.135 Section 102-80.135 Public Contracts and Property Management Federal Property... qualified fire protection engineer? A qualified fire protection engineer is defined as an individual with a..., spread, and suppression, meeting one of the following criteria: (a) An engineer having an undergraduate...

  11. 41 CFR 102-80.135 - Who is a qualified fire protection engineer?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... protection engineer? 102-80.135 Section 102-80.135 Public Contracts and Property Management Federal Property... qualified fire protection engineer? A qualified fire protection engineer is defined as an individual with a..., spread, and suppression, meeting one of the following criteria: (a) An engineer having an undergraduate...

  12. 41 CFR 102-80.135 - Who is a qualified fire protection engineer?

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... protection engineer? 102-80.135 Section 102-80.135 Public Contracts and Property Management Federal Property... qualified fire protection engineer? A qualified fire protection engineer is defined as an individual with a..., spread, and suppression, meeting one of the following criteria: (a) An engineer having an undergraduate...

  13. 41 CFR 102-80.135 - Who is a qualified fire protection engineer?

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... protection engineer? 102-80.135 Section 102-80.135 Public Contracts and Property Management Federal Property... qualified fire protection engineer? A qualified fire protection engineer is defined as an individual with a..., spread, and suppression, meeting one of the following criteria: (a) An engineer having an undergraduate...

  14. 46 CFR 28.155 - Excess fire detection and protection equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Excess fire detection and protection equipment. 28.155... protection equipment. Installation of fire detection and protection equipment in excess of that required by the regulations in this subchapter is permitted provided that the excess equipment does not endanger...

  15. 29 CFR 1915.507 - Land-side fire protection systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... specific recommendations in NFPA 14-2003 Standard for the Installation of Standpipe and Hose Systems... 29 Labor 7 2010-07-01 2010-07-01 false Land-side fire protection systems. 1915.507 Section 1915... Protection in Shipyard Employment § 1915.507 Land-side fire protection systems. (a) Employer responsibilities...

  16. Fire Safety Technician

    ERIC Educational Resources Information Center

    Moore, Pam

    2007-01-01

    Fire protection is one of the most important considerations in the construction and operation of industrial plants and commercial buildings. Fire insurance rates are determined by fire probability factors, such as the type of construction, ease of transporting personnel, and the quality and quantity of fire protection equipment available. Because…

  17. 40 CFR Appendix E to Part 75 - Optional NOX Emissions Estimation Protocol for Gas-Fired Peaking Units and Oil-Fired Peaking Units

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 17 2013-07-01 2013-07-01 false Optional NOX Emissions Estimation Protocol for Gas-Fired Peaking Units and Oil-Fired Peaking Units E Appendix E to Part 75 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION...

  18. 40 CFR Appendix E to Part 75 - Optional NOX Emissions Estimation Protocol for Gas-Fired Peaking Units and Oil-Fired Peaking Units

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 17 2014-07-01 2014-07-01 false Optional NOX Emissions Estimation Protocol for Gas-Fired Peaking Units and Oil-Fired Peaking Units E Appendix E to Part 75 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION...

  19. 33 CFR 149.641 - What are the structural fire protection requirements for accommodation spaces and modules?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... national consensus standard, as that term is defined in 29 CFR 1910.2, for the structural fire protection... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false What are the structural fire...: DESIGN, CONSTRUCTION, AND EQUIPMENT Design and Equipment Structural Fire Protection § 149.641 What are...

  20. 14 CFR 27.861 - Fire protection of structure, controls, and other parts.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire protection of structure, controls, and... Protection § 27.861 Fire protection of structure, controls, and other parts. Each part of the structure, controls, rotor mechanism, and other parts essential to a controlled landing that would be affected by...

  1. 14 CFR 27.861 - Fire protection of structure, controls, and other parts.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fire protection of structure, controls, and... Protection § 27.861 Fire protection of structure, controls, and other parts. Each part of the structure, controls, rotor mechanism, and other parts essential to a controlled landing that would be affected by...

  2. 14 CFR 29.861 - Fire protection of structure, controls, and other parts.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire protection of structure, controls, and... Protection § 29.861 Fire protection of structure, controls, and other parts. Each part of the structure, controls, and the rotor mechanism, and other parts essential to controlled landing and (for category A...

  3. 14 CFR 29.861 - Fire protection of structure, controls, and other parts.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fire protection of structure, controls, and... Protection § 29.861 Fire protection of structure, controls, and other parts. Each part of the structure, controls, and the rotor mechanism, and other parts essential to controlled landing and (for category A...

  4. 5 CFR 551.215 - Fire protection activities and 7(k) coverage for FLSA pay and exemption determinations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... similar employees involved in fire protection research or in the design and development of fire protection... Protection and Prevention series, including any qualified firefighter who is assigned to perform support... considerations; (ii) Employees in positions properly classified in other series, such as Forestry Technician, for...

  5. 5 CFR 551.215 - Fire protection activities and 7(k) coverage for FLSA pay and exemption determinations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... similar employees involved in fire protection research or in the design and development of fire protection... Protection and Prevention series, including any qualified firefighter who is assigned to perform support... considerations; (ii) Employees in positions properly classified in other series, such as Forestry Technician, for...

  6. 5 CFR 551.215 - Fire protection activities and 7(k) coverage for FLSA pay and exemption determinations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... similar employees involved in fire protection research or in the design and development of fire protection... Protection and Prevention series, including any qualified firefighter who is assigned to perform support... considerations; (ii) Employees in positions properly classified in other series, such as Forestry Technician, for...

  7. New Technology for the Fire Attire

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Although little can be done to reduce the risks of firefighting, something can be done to curb the injuries and fatalities. This is the goal of Project FIRES, a program jointly sponsored by NASA and the Federal Emergency Management Agency's U.S. Fire Administration with technical management provided by Marshall Space Flight Center. Project FIRES (Firefighter's Integrated Response Equipment System) involves applications of advanced materials and design concepts, derived from Apollo to update existing gear which does not adequately protect against many of the hazards encountered in fire suppression activities. A major focus of the effort involves application to the FIRES ensemble of lightweight, fire-resistant, heat-protective materials originally developed for use in astronauts' space suits or in spacecraft components which require thermal protection. Data from the fourteen municipal fire departments participating in the field evaluation will form a basis for development of new nationwide protective ensemble students.

  8. Fire Incident Reporting Manual

    DTIC Science & Technology

    1984-02-01

    Purpose 1-1 B. Scope 1-1 C. Procedures 1-1 D. Exclusions 1-3 E . Preparation 1-3 F. Information Requirements 1-4 CHAPTER 2 - INSTRUCTIONS FOR PREPARING DoD...Structure and Fire Data 2-16 4. Section D - Fire Protection Facilities (In Structures Only) 2-28 5. Section E - Losses 2-30 6. Section F - Times (24...Activities Program," February 21, 1976 ( e ) National Fire Protection Association (NFPA) Standard 901, "Uniform Coding for Fire Protection," 1976 (f) NFPA

  9. Water cooled steam jet

    DOEpatents

    Wagner, E.P. Jr.

    1999-01-12

    A water cooled steam jet for transferring fluid and preventing vapor lock, or vaporization of the fluid being transferred, has a venturi nozzle and a cooling jacket. The venturi nozzle produces a high velocity flow which creates a vacuum to draw fluid from a source of fluid. The venturi nozzle has a converging section connected to a source of steam, a diffuser section attached to an outlet and a throat portion disposed there between. The cooling jacket surrounds the venturi nozzle and a suction tube through which the fluid is being drawn into the venturi nozzle. Coolant flows through the cooling jacket. The cooling jacket dissipates heat generated by the venturi nozzle to prevent vapor lock. 2 figs.

  10. Designing insulation for cryogenic ducts

    NASA Astrophysics Data System (ADS)

    Love, C. C.

    1984-03-01

    It is pointed out that the great temperature difference between the outside of a cryogenic duct and the liquified gas it carries can cause a high heat input unless blocked by a high thermal resistance. High thermal resistance for lines needing maximum insulation is provided by metal vacuum jackets. Low-density foam is satisfactory in cases in which higher heat input can be tolerated. Attention is given to the heat transfer through a duct vacuum jacket, the calculation of heat input and the exterior surface's steady-state temperature for various thicknesses of insulation, the calculation of the heat transfer through gimbal jackets, and design specifications regarding the allowable pressure rise in the jacket's annular space.

  11. Emergency Response Capability Baseline Needs Assessment - Requirements Document

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sharry, John A.

    This document was prepared by John A. Sharry, LLNL Fire Marshal and LLNL Division Leader for Fire Protection and reviewed by LLNL Emergency Management Department Head James Colson. The document follows and expands upon the format and contents of the DOE Model Fire Protection Baseline Capabilities Assessment document contained on the DOE Fire Protection Web Site, but only addresses emergency response.

  12. 10 CFR Appendix R to Part 50 - Fire Protection Program for Nuclear Power Facilities Operating Prior to January 1, 1979

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... could occur in a nuclear power plant. These sessions shall provide brigade members with experience in... A. Fire protection program. A fire protection program shall be established at each nuclear power... fires that could occur in the plant and in using the types of equipment available in the nuclear power...

  13. DEVELOPMENT OF ALTERNATIVE, NON-HALOGEN FIRE PROTECTION SYSTEM

    EPA Science Inventory

    With the phaseout of halon production, two alternative technologies - water misting and low-residue particulates - have come to the fire protection forefront. These technologies use water or dry chemicals in reduced quantities to provide acceptable fire protection. A review and a...

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sanger, P.; Adam, E.; Grabinsky, G.

    A conductor using flowing supercritical helium as a coolant has been adopted for the superconducting magnet being built by the Airco-Westinghouse team for the LCP at Oak Ridge National Laboratory. This conductor utilizes the ''rope in a pipe'' concept in which a large number of superconductor Nb/sub 3/Sn strands are formed into a cable and wrapped in a stainless steel jacket. The jacket material and conductor processing are given; the sequence of forming stages involved in producing the jacket is illustrated. It is found that the adoption of the iron-based superalloy JBK-75 as the jacket material revealed problems significantly differentmore » from those of the 304L and 21-6-9 stainless steel jackets. These problems included poor abrasion behavior, different reactions to cold reduction, and the presence of aluminum and titanium oxide floaters on the welds. The research underscores the fact that many material properties involved in proper selection are not well understood a priori and can only be determined by trial and error.« less

  15. JACKETED URANIUM SLUG

    DOEpatents

    Ohlinger, L.A.; Cooper, C.M.

    1958-10-01

    Fuel elements for nuclear reactors are described. Eacb fuel element is comprised of a solid cylindrical slug containing fissionable material enclosed within a fluid tight jacket of neutron permeable material such as aluminum. The jacket is provided with a flexible end cap and with a sealing member having a substantially fluid-tight fit within the jacket in tight abutment with the end cap and the end of the slug. A fluid passage is provided between the end of the slug and the cap whereby leakage fiuid is principally directed to the end of the slug. In this manner, any reaction between the fissionable material and fiuid which may take place occurs more rapidly at the end of the slug than along the sides between the slug and the jacket, thereby causing longitudinal expansion of the fuel element prior to radial expansion. The longitudinal expansion can be readily detected and the fuel element removed from the coolant tube before radial expansion causes it to become jammed in the tube.

  16. METHOD AND APPARATUS FOR CONTROLLING NEUTRON DENSITY

    DOEpatents

    Wigner, E.P.; Young, G.J.; Weinberg, A.M.

    1961-06-27

    A neutronic reactor comprising a moderator containing uniformly sized and spaced channels and uniformly dimensioned fuel elements is patented. The fuel elements have a fissionable core and an aluminum jacket. The cores and the jackets of the fuel elements in the central channels of the reactor are respectively thinner and thicker than the cores and jackets of the fuel elements in the remainder of the reactor, producing a flattened flux.

  17. An Innovative Cooling Jacket to Combat Heat Intolerance in Children with Anhidrosis.

    PubMed

    Inamadar, Arun C; Palit, Aparna; Khurana, Neha

    2017-07-01

    Hyperthermia and heat intolerance are distressing symptoms in patients with anhidrosis. Body cooling devices are an integral part of management of these patients. A cooling jacket made from easily available materials has been invented for a girl with congenital insensitivity to pain and anhidrosis with severe heat intolerance. This innovative cooling jacket may be helpful for anhidrotic children in resource-poor situations. © 2017 Wiley Periodicals, Inc.

  18. 41 CFR 102-80.90 - Is the Fire Administration Authorization Act of 1992 (Public Law 102-522) relevant to fire...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 41 Public Contracts and Property Management 3 2011-01-01 2011-01-01 false Is the Fire Administration Authorization Act of 1992 (Public Law 102-522) relevant to fire protection engineering? 102-80.90... Authorization Act of 1992 (Public Law 102-522) relevant to fire protection engineering? Yes, the Fire...

  19. 41 CFR 102-80.90 - Is the Fire Administration Authorization Act of 1992 (Public Law 102-522) relevant to fire...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Is the Fire Administration Authorization Act of 1992 (Public Law 102-522) relevant to fire protection engineering? 102-80.90... Authorization Act of 1992 (Public Law 102-522) relevant to fire protection engineering? Yes, the Fire...

  20. 41 CFR 102-80.90 - Is the Fire Administration Authorization Act of 1992 (Public Law 102-522) relevant to fire...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 41 Public Contracts and Property Management 3 2012-01-01 2012-01-01 false Is the Fire Administration Authorization Act of 1992 (Public Law 102-522) relevant to fire protection engineering? 102-80.90... Authorization Act of 1992 (Public Law 102-522) relevant to fire protection engineering? Yes, the Fire...

  1. 41 CFR 102-80.90 - Is the Fire Administration Authorization Act of 1992 (Public Law 102-522) relevant to fire...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 41 Public Contracts and Property Management 3 2013-07-01 2013-07-01 false Is the Fire Administration Authorization Act of 1992 (Public Law 102-522) relevant to fire protection engineering? 102-80.90... Authorization Act of 1992 (Public Law 102-522) relevant to fire protection engineering? Yes, the Fire...

  2. 41 CFR 102-80.90 - Is the Fire Administration Authorization Act of 1992 (Public Law 102-522) relevant to fire...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 41 Public Contracts and Property Management 3 2014-01-01 2014-01-01 false Is the Fire Administration Authorization Act of 1992 (Public Law 102-522) relevant to fire protection engineering? 102-80.90... Authorization Act of 1992 (Public Law 102-522) relevant to fire protection engineering? Yes, the Fire...

  3. Linking management effectiveness indicators to observed effects of protected areas on fire occurrence in the Amazon rainforest.

    PubMed

    Nolte, Christoph; Agrawal, Arun

    2013-02-01

    Management-effectiveness scores are used widely by donors and implementers of conservation projects to prioritize, track, and evaluate investments in protected areas. However, there is little evidence that these scores actually reflect the capacity of protected areas to deliver conservation outcomes. We examined the relation between indicators of management effectiveness in protected areas and the effectiveness of protected areas in reducing fire occurrence in the Amazon rainforest. We used data collected with the Management Effectiveness Tracking Tool (METT) scorecard, adopted by some of the world's largest conservation organizations to track management characteristics believed to be crucial for protected-area effectiveness. We used the occurrence of forest fires from 2000 through 2010 as a measure of the effect of protected areas on undesired land-cover change in the Amazon basin. We used matching to compare the estimated effect of protected areas with low versus high METT scores on fire occurrence. We also estimated effects of individual protected areas on fire occurrence and explored the relation between these effects and METT scores. The relations between METT scores and effects of protected areas on fire occurrence were weak. Protected areas with higher METT scores in 2005 did not seem to have performed better than protected areas with lower METT scores at reducing fire occurrence over the last 10 years. Further research into the relations between management-effectiveness indicators and conservation outcomes in protected areas seems necessary, and our results show that the careful application of matching methods can be a suitable method for that purpose. ©2012 Society for Conservation Biology.

  4. Using the HELIOS facility for assessment of bundle-jacket thermal coupling in a CICC

    NASA Astrophysics Data System (ADS)

    Lacroix, B.; Rousset, B.; Cloez, H.; Decool, P.; Duchateau, J. L.; Hoa, C.; Luchier, N.; Nicollet, S.; Topin, F.

    2016-12-01

    In a Cable In Conduit Conductor (CICC) cooled by forced circulation of supercritical helium, the heat exchange in the bundle region can play a significant role for conductor safe operation, while remaining a quite uncertain parameter. Heat exchange between bundle and jacket depends on the relative contributions of convective heat transfer due to the helium flow inside the bundle and of thermal resistance due to the wrappings between the cable and the conduit. In order to qualify this thermal coupling at realistic operating conditions, a dedicated experiment on a 1.2 m sample of ITER Toroidal Field (TF) dummy conductor was designed and performed in the HELIOS test facility at CEA Grenoble. Several methods were envisaged, and the choice was made to assess bundle-jacket heat transfer coefficient by measuring the temperature of a solid copper cylinder inserted over the conductor jacket and submitted to heat deposition on its outer surface. The mock-up was manufactured and tested in spring 2015. Bundle-jacket heat transfer coefficient was found in the range 300-500 W m-2 K-1. Results analysis suggests that the order of magnitude of convective heat transfer coefficient inside bundle is closer to Colburn-Reynolds analogy than to Dittus-Boelter correlation, and that bundle-jacket thermal coupling is mainly limited by thermal resistance due to wrappings. A model based on an equivalent layer of stagnant helium between wraps and jacket was proposed and showed a good consistency with the experiment, with relevant values for the helium layer thickness.

  5. Deformation and Heat Transfer on Three Sides Protected Beams under Fire Accident

    NASA Astrophysics Data System (ADS)

    Imran, M.; Liew, M. S.; Garcia, E. M.; Nasif, M. S.; Yassin, A. Y. M.; Niazi, U. M.

    2018-04-01

    Fire accidents are common in oil and gas industry. The application of passive fire protection (PFP) is a costly solution. The PFP is applied only on critical structural members to optimise project cost. In some cases, beams cannot be protected from the top flange in order to accommodate for the placement of pipe supports and grating. It is important to understand the thermal and mechanical response of beam under such condition. This paper discusses the response of steel beam under ISO 834 fire protected, unprotected and three sides protected beams. The model validated against an experimental study. The experimental study has shown good agreement with FE model. The study revealed that the beams protected from three sides heat-up faster compare to fully protected beam showing different temperature gradient. However, the affects load carrying capacity are insignificant under ISO 834 fire.

  6. Integrated Personal Protective Equipment Standards Support Model

    DTIC Science & Technology

    2008-04-01

    traditional SCBA showed that the distribution of the weight is important as well. Twelve firefighters performed simulated fire -fighting and rescue exercises...respiratory equipment standards and five National Fire Protection Association (NFPA) protective suit, clothing, and respirator standards. The...respirators. The clothing standards were for protective ensembles for urban search and rescue operations, open circuit SCBA for fire and emergency

  7. The Compressive Failure of Aluminum Nitride Considered as a Model Advanced Ceramic

    DTIC Science & Technology

    2012-06-01

    and fragmentation of hot-pressed silicon carbide under uniaxial compression. Acta Materialia 52 (2), 355–367. Xia, Q., Xia, H., Ruoff, A.L., 1993...Orphal et al., 1996) both as a standalone material and as part of ceramic composites (particularly with SiC ). Much of the literature on bulk...compression experiments. Tungsten carbide platens jacketed by the Ti-6Al-4V titanium alloy were used to protect the loading surfaces of the testing

  8. 14 CFR 25.854 - Lavatory fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Fire Protection § 25.854 Lavatory fire protection. For airplanes with a passenger capacity of 20 or more: (a) Each lavatory must be... disposal receptacle for towels, paper, or waste, located within the lavatory. The extinguisher must be...

  9. Sprinkler System Installer. Occupational Analyses Series.

    ERIC Educational Resources Information Center

    Chinien, Chris; Boutin, France

    This analysis covers tasks performed by a sprinkler system installer, an occupational title some provinces and territories of Canada have also identified as pipefitter--fire protection mechanic specialty; sprinkler and fire protection installer; sprinkler and fire protection systems installer; and sprinkler fitter. A guide to analysis discusses…

  10. The technique of numerical research of cooling medium flow in the water jacket of self-lubricated bearing

    NASA Astrophysics Data System (ADS)

    Raikovskiy, N. A.; Tretyakov, A. V.; Abramov, S. A.; Nazmeev, F. G.; Pavlichev, S. V.

    2017-08-01

    The paper presents a numerical study method of the cooling medium flowing in the water jacket of self-lubricating sliding bearing based on ANSYS CFX. The results of numerical calculations have satisfactory convergence with the empirical data obtained on the testbed. Verification data confirm the possibility of applying this numerical technique for the analysis of coolant flowings in the self-lubricating bearing containing the water jacket.

  11. Destabilization and intracranial fragmentation of a full metal jacket bullet.

    PubMed

    Farrugia, A; Raul, J S; Geraut, A; Tortel, M C; Ludes, B

    2009-10-01

    We report a case with an atypical entrance wound as a result of a destabilized full metal jacket bullet penetration. The destabilized bullet by an impact with the dorsal hand experiences a yawing to tumbling motion in flight. The large angle of yaw induces a larger presenting profile upon impact that contributes, associated to a rapid deceleration, to a greater mechanical force on the projectile structure and a fragmentation into core and jacket. Forensic pathologists have to be aware that the metal jacket bullet could tend to break up outside or inside the body particularly after a shooting through a target. This phenomenon induces atypical entrance wounds and atypical X-ray presentation. 2009 Elsevier Ltd and Faculty of Forensic and Legal Medicine.

  12. History of Fire Events in the U.S. Commercial Nuclear Industry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bijan Najafi; Joglar-Biloch, Francisco; Kassawara, Robert P.

    2002-07-01

    Over the past decade, interest in performance-based fire protection has increased within the nuclear industry. In support of this growing interest, in 1997 the Electric Power Research Institute (EPRI) developed a long-range plan to develop/improve data and tools needed to support Risk-Informed/Performance-Based fire protection. This plan calls for continued improvement in collection and use of information obtained from fire events at nuclear plants. The data collection process has the objectives of improving the insights gained from such data and reducing the uncertainty in fire risk and fire modeling methods in order to make them a more reliable basis for performancemore » based fire protection programs. In keeping with these objectives, EPRI continues to collect, review and analyze fire events in support of the nuclear industry. EPRI collects these records in cooperation with the Nuclear Electric Insurance Limited (NEIL), by compiling public fire event reports and by direct solicitation of U.S. nuclear facilities. EPRI fire data collection project is based on the principle that the understanding of history is one of the cornerstones of improving fire protection technology and practice. Therefore, the goal has been to develop and maintain a comprehensive database of fire events with flexibility to support various aspects of fire protection engineering. With more than 1850 fire records over a period of three decades and 2400 reactor years, this is the most comprehensive database of nuclear power industry fire events in existence today. In general, the frequency of fires in the U.S. commercial nuclear industry remains constant. In few cases, e.g., transient fires and fires in BWR offgas/recombiner systems, where either increasing or decreasing trends are observed, these trends tend to slow after 1980. The key issues in improving quality of the data remain to be consistency of the recording and reporting of fire events and difficulties in collection of records. EPRI has made significant progress towards improving the quality of the fire events data through use of multiple collection methods as well as its review and verification. To date EPRI has used this data to develop a generic fire ignition frequency model for U.S. nuclear power industry (Ref. 1, 4 and 5) as well as to support other models in support of EPRI Fire Risk Methods such as a cable fire manual suppression model. EPRI will continue its effort to collect and analyze operating data to support risk informed/performance based fire safety engineering, including collection and analysis of impairment data for fire protection systems and features. This paper provides details on the collection and application of fire events to risk informed/performance based fire protection. The paper also provides valuable insights into improving both collection and use of fire events data. (authors)« less

  13. 14 CFR 29.1359 - Electrical system fire and smoke protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Equipment Electrical Systems and Equipment § 29.1359 Electrical system fire and smoke protection. (a) Components of the electrical system... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Electrical system fire and smoke protection...

  14. Thermal Response of UHMWPE Materials in a Flash Flame Test Environment

    DTIC Science & Technology

    2014-11-13

    Evaluation of Flame Resistant Clothing for Protection Against Fire Simulations Using an Instrumented Manikin. Several UHMWPE fabrics were tested underneath...PROTECTIVE CLOTHING COTTON FLASH FLAMES UNDERGARMENTS TEST AND EVALUATION FABRICS FLAME TESTING FIRE ...PROTECTION FIRE RESISTANT TEXTILES UHMWPE(ULTRA HIGH MOLECULAR WEIGHT POLYETHYLENE

  15. Safety survey report EBR-II safety survey, ANL-west health protection, industrial safety and fire protection survey

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dunbar, K.A.

    1972-01-10

    A safety survey covering the disciplines of Reactor Safety, Nuclear Criticality Safety, Health Protection and Industrial Safety and Fire Protection was conducted at the ANL-West EBR-II FEF Complex during the period January 10-18, 1972. In addition, the entire ANL-West site was surveyed for Health Protection and Industrial Safety and Fire Protection. The survey was conducted by members of the AEC Chicago Operations Office, a member of RDT-HQ and a member of the RDT-ID site office. Eighteen recommendations resulted from the survey, eleven in the area of Industrial Safety and Fire Protection, five in the area of Reactor Safety and twomore » in the area of Nuclear Criticality Safety.« less

  16. 40 CFR Appendix D to Part 75 - Optional SO2 Emissions Data Protocol for Gas-Fired and Oil-Fired Units

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 17 2014-07-01 2014-07-01 false Optional SO2 Emissions Data Protocol for Gas-Fired and Oil-Fired Units D Appendix D to Part 75 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Pt. 75, App. D Appendix D to Part 75—Optional SO2 Emissions Data...

  17. CFES--California Fire Economics Simulator: A Computerized System for Wildland Fire Protection Planning

    Treesearch

    Jeremy S. Fried; J. Keith Gilless; Robert E. Martin

    1987-01-01

    The University of California's Department of Forestry and Resource Management, under contract with the California Department of Forestry and Fire Protection, has developed and released the first version of the California Fire Economics Simulator (CFES). The current release is adapted from the Initial Action Assessment component of the USFS's National Fire...

  18. 29 CFR Appendix A to Subpart P to... - Model Fire Safety Plan (Non-Mandatory)

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Subpart P to Part 1915 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH... Fire Protection in Shipyard Employment Pt. 1915, Subpt. P, App. A Appendix A to Subpart P to Part 1915... fire. D. Potential ignition sources for fires and how to control them. E. Types of fire protection...

  19. 29 CFR Appendix A to Subpart P to... - Model Fire Safety Plan (Non-Mandatory)

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Subpart P to Part 1915 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH... Fire Protection in Shipyard Employment Pt. 1915, Subpt. P, App. A Appendix A to Subpart P to Part 1915... fire. D. Potential ignition sources for fires and how to control them. E. Types of fire protection...

  20. Behaviour of tunnel lining material in road tunnel fire

    NASA Astrophysics Data System (ADS)

    Tomar, M.; Khurana, S.; Singh, R.

    2018-04-01

    The worldwide road tunnel linings are protected against possible fire scenarios to safeguard the structure and assist in occupant evacuation. There are various choices of active and passive protection available, passive protections includes calcium silicate boards, polypropylene fibers, vermiculite cement based sprays, and other intumescent materials. Tunnel fire is a complex phenomenon and researchers in the past has highlighted that there are various factors which affect the tunnel fires. The effect of passive protection techniques on tunnel fire is not well understood, especially for the insulation boards. It’s been understood from past research that for a heavy good vehicular (HGV) fire in the tunnel, the heat feedback effect is significant. Insulation boards may also affect the tunnel fires by altering the heat feedback effect in vehicular tunnels and hence this can affect the overall heat release rates and temperature profile inside a tunnel. This study focuses on studying the role of insulation boards in tunnel fires and evaluating its effect on overall heat release rate and tunnel temperatures.

  1. Manual Fire Suppression Methods on Typical Machinery Space Spray Fires

    DTIC Science & Technology

    1990-07-31

    Aqueous Film Forming Foam Manuscnpt approved April 25, 1990. ( AFFF ), has been incorporated in machinery space fire protection systems to...distribution unlimited. 13. ABSTRACT (Maximum 200 words) A series of tests was conducted to evaluate the effectiveness of Aqueous Film Forming Foami ( AFFF ...machinery space fire protection systems to control running fuel and fuel spray fires (PKP side of TAFES), and bilge fires ( aqueous film forming foam

  2. 33 CFR 127.1507 - Water systems for fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Water systems for fire protection... HAZARDOUS GAS Waterfront Facilities Handling Liquefied Hazardous Gas Firefighting Equipment § 127.1507 Water systems for fire protection. (a) Each waterfront facility handling LHG must have a supply of water and a...

  3. 14 CFR 25.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Flammable fluid fire protection. 25.863....863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might escape by..., fireproof containment, or use of extinguishing agents. (5) Ability of airplane components that are critical...

  4. 14 CFR 27.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Flammable fluid fire protection. 27.863....863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might escape by..., fireproof containment, or use of extinguishing agents. (5) Ability of rotorcraft components that are...

  5. 14 CFR 27.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Flammable fluid fire protection. 27.863....863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might escape by..., fireproof containment, or use of extinguishing agents. (5) Ability of rotorcraft components that are...

  6. 14 CFR 29.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Flammable fluid fire protection. 29.863... § 29.863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might..., shutting down equipment, fireproof containment, or use of extinguishing agents. (5) Ability of rotorcraft...

  7. 14 CFR 29.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Flammable fluid fire protection. 29.863... § 29.863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might..., shutting down equipment, fireproof containment, or use of extinguishing agents. (5) Ability of rotorcraft...

  8. 14 CFR 25.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Flammable fluid fire protection. 25.863....863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might escape by..., fireproof containment, or use of extinguishing agents. (5) Ability of airplane components that are critical...

  9. 14 CFR 29.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Flammable fluid fire protection. 29.863... § 29.863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might..., shutting down equipment, fireproof containment, or use of extinguishing agents. (5) Ability of rotorcraft...

  10. 14 CFR 29.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Flammable fluid fire protection. 29.863... § 29.863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might..., shutting down equipment, fireproof containment, or use of extinguishing agents. (5) Ability of rotorcraft...

  11. 14 CFR 25.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Flammable fluid fire protection. 25.863....863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might escape by..., fireproof containment, or use of extinguishing agents. (5) Ability of airplane components that are critical...

  12. 14 CFR 27.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Flammable fluid fire protection. 27.863....863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might escape by..., fireproof containment, or use of extinguishing agents. (5) Ability of rotorcraft components that are...

  13. 14 CFR 25.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Flammable fluid fire protection. 25.863....863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might escape by..., fireproof containment, or use of extinguishing agents. (5) Ability of airplane components that are critical...

  14. 14 CFR 27.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Flammable fluid fire protection. 27.863....863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might escape by..., fireproof containment, or use of extinguishing agents. (5) Ability of rotorcraft components that are...

  15. 14 CFR 27.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Flammable fluid fire protection. 27.863....863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might escape by..., fireproof containment, or use of extinguishing agents. (5) Ability of rotorcraft components that are...

  16. Safe Passage

    ERIC Educational Resources Information Center

    Razwick, Jeff

    2007-01-01

    Many schools are almost entirely reliant on alarms and sprinklers for their fire protection. As these devices need to be triggered and supplied with power or water to work properly, they are vulnerable to errors. To provide adequate safety, a good fire-protection program must have three primary elements: fire protection and suppression, and…

  17. Protection against fire in the mountainous forests of Greece case study: forest complex of W. Nestos

    NASA Astrophysics Data System (ADS)

    Drosos, Vasileios C.; Giannoulas, Vasileios J.; Stergiadou, Anastasia; Karagiannis, Evaggelos; Doukas, Aristotelis-Kosmas G.

    2014-08-01

    Forest fires are an ancient phenomenon. Appear, however, with devastating frequency and intensity over the last 30 years. In our country, the climatic conditions in combination with the intense relief, favor their rapid spread. Considering the fact that environmental conditions provided for decades even worse (increased temperature, drought and vegetation), then the problem of forest fires in our country, is expected to become more intense. The work focuses on the optimization model of the opening up of the forest mountain areas taking into account the prevention and suppression of forest fires. Research area is the mountain forest complex of W. Nestos of Drama Prefecture. The percentage of forest protection area is examined under the light whether the total hose length corresponds to the actual operational capacity to reach a fire source. For this reason are decided to present a three case study concerning area of the forest being protected by fire extinguishing vehicles. The first one corresponds to a fire suppression bandwidth (buffer zone) with a capacity radius of 150m uphill and 250m downhill from the origin point where the fire extinguishing vehicle stands. The second one corresponds to a fire suppression capacity of 200m uphill and 400m downhill and the third one corresponds to a fire suppression capacity of 300m uphill and 500m downhill. The most important forest technical infrastructures to prevent fire are roads network (opening up) for fire protection and buffer zones. Patrols of small and agile 4 × 4 appropriately equipped (pipe length of 500 meters and putting pressure on uphill to 300 meters) for the first attack of the fire in the summer months coupled with early warning of fire observatories adequately cover the forest protection of W. Nestos complex. But spatial distribution needed improvements to a road density of the optimum economic Dec, both forest protection and for better management (skidding) of woody capital.

  18. The usage of phase change materials in fire fighter protective clothing: its effect on thermal protection

    NASA Astrophysics Data System (ADS)

    Zhao, Mengmeng

    2017-12-01

    The thermal protective performance of the fire fighter protective clothing is of vital importance for fire fighters. In the study fabrics treated by phase change materials (PCMs) were applied in the multi-layered fabrics of the fire fighter protective clothing ensemble. The PCM fabrics were placed at the different layers of the clothing and their thermal protective performance were measured by a TPP tester. Results show that with the application of the PCM fabrics the thermal protection of the multi-layered fabrics was greatly increased. The time to reach a second degree burn was largely reduced. The location of the PCM fabrics at the different layers did not affect much on the thermal protective performance. The higher amount of the PCM adds on, the higher thermal protection was brought. The fabrics with PCMs of a higher melting temperature could contribute to higher thermal protection.

  19. Experimental Study on the Fire Performance of Tubular Steel Columns with Membrane Protections for Prefabricated and Modular Steel Construction

    PubMed Central

    Zhang, Xin; Peng, Lei; Ni, Zhao-peng; Ni, Tian-xiao; Huang, Yi-liang; Zhou, Yang

    2018-01-01

    Experimental research was conducted to study the fire resistance of steel tubular columns used in prefabricated and modular construction. In order to achieve high-efficient prefabrication and fast on-site installation, membrane protections using board products and thermal insulation blankets are adopted as the favorable protection method. Three protected tubular columns were tested in a full-scale column furnace with axial load applied. The study variables were different membranes, including fiber reinforced calcium silicate (FRCS) boards, rock wool and aluminum silica (Fiberfrax) insulations. The results suggest that one layer of 12 mm FRCS board with rock wool insulation has insufficient fire protection. However, steel columns protected with two layers of 12 mm FRCS boards with insulation appeared to have good fire resistances and could achieve a fire resistance rating as high as 2.5~3.0 h. PMID:29547574

  20. Confined Tension and Triaxial Extension Tests on Eglin High-Strength Concrete

    DTIC Science & Technology

    2014-10-17

    specimen were filled with Devcon 5-Minute epoxy . We encased the specimen in a liquid-tight flexible jacket to exclude the confining fluid from any...sealed to the steel endcaps with epoxy and wire clamps. Figure 3. Schematic diagram of test specimen prepared for TXE testing. TXE tests are...150 MPa – we wrapped two Kevlar jackets (0.01 in thick) around the specimen prior to installing the polyolefin jacket (0.02 in thick). The Kevlar

  1. Piano jacket for perceiving and playing music for patients with cerebral palsy.

    PubMed

    Lampe, Renée; Turova, Varvara; Alves-Pinto, Ana

    2017-12-23

    Patients with cerebral palsy with severe motor disabilities are limited not only in everyday life activities but also in choice of their hobbies. Playing a musical instrument is for the majority not possible, even though music constitutes a central component of many relaxation activities for people with disabilities. To give affected patients the opportunity to make music and to learn piano playing through somatosensory perception, a prototype of piano jacket was developed. A cycling jacket was equipped with boxes, each representing a musical note, incorporated into the sleeves. Each box contains vibration motors and LEDs. These can be used to translate the sequences of piano key presses performed at an external E-piano. An additional operation mode allows the user to actively play a melody himself by touching the same boxes that also incorporate touch sensor components. A working prototype of the piano jacket was developed. The sensory piano jacket provides patients with cerebral palsy and contractures the possibility to develop sensorimotor skills, motor abilities and participation in music-related activities. The jacket is planned to be used in music lessons. Implications for Rehabilitation The system is suitable even for patients with severe motor disabilities and especially joint contractures. Excellent handling through large easily accessible communication buttons. All building blocks are held in a garment, which allows for easy portability and gripping comfort.

  2. Modeling heat and moisture transport in firefighter protective clothing during flash fire exposure

    NASA Astrophysics Data System (ADS)

    Chitrphiromsri, Patirop; Kuznetsov, Andrey V.

    2005-01-01

    In this paper, a model of heat and moisture transport in firefighter protective clothing during a flash fire exposure is presented. The aim of this study is to investigate the effect of coupled heat and moisture transport on the protective performance of the garment. Computational results show the distribution of temperature and moisture content in the fabric during the exposure to the flash fire as well as during the cool-down period. Moreover, the duration of the exposure during which the garment protects the firefighter from getting second and third degree burns from the flash fire exposure is numerically predicted. A complete model for the fire-fabric-air gap-skin system is presented.

  3. 77 FR 31325 - National Fire Codes: Request for Comments on NFPA Technical Committee Reports

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-25

    ... DEPARTMENT OF COMMERCE National Institute of Standards and Technology National Fire Codes: Request... publishing this notice on behalf of the National Fire Protection Association (NFPA) to announce the... National Fire Protection Association (NFPA) has accomplished its mission by advocating scientifically based...

  4. 77 FR 74381 - Protection of Stratospheric Ozone: Listing of Substitutes for Ozone Depleting Substances-Fire...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-14

    ... Protection of Stratospheric Ozone: Listing of Substitutes for Ozone Depleting Substances--Fire Suppression... a companion proposed rule issuing listings for three fire suppressants under EPA's Significant New... companion proposed rule issuing listings for three fire suppressants under EPA's Significant New...

  5. In situ thermal condensation of glucose-diammonium phosphate in wood for fire and fungal decay protection

    Treesearch

    George Chen

    2009-01-01

    Thermal condensation of glucose-diammonium phosphate in wood at 160 and 190[degrees]C will protect wood against fire and decay in one treatment using an aqueous system. For fire protection, treatments at 160 or 190[degrees]C led to low flammability as evidenced by fire-tube tests. For nonleached wood, weight losses were 1.9, 2.0, and 2.0% with chemical retentions of 56...

  6. Forest fire laboratory at Riverside and fire research in California: past, present, and future

    Treesearch

    Carl C. Wilson; James B. Davis

    1988-01-01

    The need for protection from uncontrolled fire in California was identified by Abbott Kinney, Chairman of the State Board of Forestry, more than 75 years before the construction of the Riverside Forest Fire Laboratory. With the organization of the USDA Forest Service the need for an effective fire protection organization became apparent. In response, a...

  7. 14 CFR 29.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Design and Construction Fire Protection... sources, including electrical faults, overheating of equipment, and malfunctioning of protective devices...

  8. What Is A Picture Archiving And Communication System (PACS)?

    NASA Astrophysics Data System (ADS)

    Marceau, Carla

    1982-01-01

    A PACS is a digital system for acquiring, storing, moving and displaying picture or image information. It is an alternative to film jackets that has been made possible by recent breakthroughs in computer technology: telecommunications, local area nets and optical disks. The fundamental concept of the digital representation of image information is introduced. It is shown that freeing images from a material representation on film or paper leads to a dramatic increase in flexibility in our use of the images. The ultimate goal of a medical PACS system is a radiology department without film jackets. The inherent nature of digital images and the power of the computer allow instant free "copies" of images to be made and thrown away. These copies can be transmitted to distant sites in seconds, without the "original" ever leaving the archives of the radiology department. The result is a radiology department with much freer access to patient images and greater protection against lost or misplaced image information. Finally, images in digital form can be treated as data for the computer in image processing, which includes enhancement, reconstruction and even computer-aided analysis.

  9. 30 CFR 77.1916 - Welding, cutting, and soldering; fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Welding, cutting, and soldering; fire... OF UNDERGROUND COAL MINES Slope and Shaft Sinking § 77.1916 Welding, cutting, and soldering; fire protection. (a) One portable fire extinguisher shall be provided where welding, cutting, or soldering with...

  10. New fire retardant foams and intumescents

    NASA Technical Reports Server (NTRS)

    Parker, J. A.

    1972-01-01

    The development of fire retardant foams and intumescent paints for protection of commercial aircraft passengers in the event of fire is discussed. Recommended materials and methods for evaluating the effectiveness of the materials are presented. Typical problems resulting from aircraft fires and the basic protective mechanisms to cope with these problems are examined.

  11. 77 FR 67628 - National Fire Codes: Request for Public Input for Revision of Codes and Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-13

    ... DEPARTMENT OF COMMERCE National Institute of Standards and Technology National Fire Codes: Request... Technology, Commerce. ACTION: Notice. SUMMARY: This notice contains the list of National Fire Protection... the National Fire Protection Association (NFPA) to announce the NFPA's proposal to revise some of its...

  12. 78 FR 24729 - National Fire Codes: Request for Comments on NFPA's Codes and Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-26

    ... DEPARTMENT OF COMMERCE National Institute of Standards and Technology National Fire Codes: Request... this notice on behalf of the National Fire Protection Association (NFPA) to announce the availability...: Since 1896, the National Fire Protection Association (NFPA) has accomplished its mission by advocating...

  13. 78 FR 24725 - National Fire Codes: Request for Public Input for Revision of Codes and Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-26

    ... DEPARTMENT OF COMMERCE National Institute of Standards and Technology National Fire Codes: Request... Technology, Commerce. ACTION: Notice. SUMMARY: This notice contains the list of National Fire Protection... the National Fire Protection Association (NFPA) to announce the NFPA's proposal to revise some of its...

  14. 76 FR 22381 - National Fire Codes: Request for Comments on NFPA Technical Committee Reports

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-21

    ... DEPARTMENT OF COMMERCE National Institute of Standards and Technology National Fire Codes: Request... publishing this notice on behalf of the National Fire Protection Association (NFPA) to announce the..., Massachusetts 02169-7471, (617) 770-3000. SUPPLEMENTARY INFORMATION: Since 1896, the National Fire Protection...

  15. Managing the Library Fire Risk.

    ERIC Educational Resources Information Center

    Morris, John

    A discussion of fire risks, causes, prevention, and salvage in libraries is presented in text and photographs. A description of some historic library fires demonstrates the value of adequate protection and preparedness programs to minimize loss and damage. The need for fire retardant construction and protection from valdalism and arson are…

  16. 30 CFR 77.1916 - Welding, cutting, and soldering; fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Welding, cutting, and soldering; fire... OF UNDERGROUND COAL MINES Slope and Shaft Sinking § 77.1916 Welding, cutting, and soldering; fire protection. (a) One portable fire extinguisher shall be provided where welding, cutting, or soldering with...

  17. 30 CFR 77.1916 - Welding, cutting, and soldering; fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Welding, cutting, and soldering; fire... OF UNDERGROUND COAL MINES Slope and Shaft Sinking § 77.1916 Welding, cutting, and soldering; fire protection. (a) One portable fire extinguisher shall be provided where welding, cutting, or soldering with...

  18. 30 CFR 77.1916 - Welding, cutting, and soldering; fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Welding, cutting, and soldering; fire... OF UNDERGROUND COAL MINES Slope and Shaft Sinking § 77.1916 Welding, cutting, and soldering; fire protection. (a) One portable fire extinguisher shall be provided where welding, cutting, or soldering with...

  19. 30 CFR 77.1916 - Welding, cutting, and soldering; fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Welding, cutting, and soldering; fire... OF UNDERGROUND COAL MINES Slope and Shaft Sinking § 77.1916 Welding, cutting, and soldering; fire protection. (a) One portable fire extinguisher shall be provided where welding, cutting, or soldering with...

  20. Management impacts on fire occurrence: A comparison of fire regimes of African and South American tropical savannas in different protected areas.

    PubMed

    Alvarado, Swanni T; Silva, Thiago Sanna Freire; Archibald, Sally

    2018-07-15

    Humans can alter fire dynamics in grassland systems by changing fire frequency, fire seasonality and fuel conditions. These changes have effects on vegetation structure and recovery, species composition, and ecosystem function. Understanding how human management can affect fire regimes is vital to detect potential changes in the resilience of plant communities, and to predict vegetation responses to human interventions. We evaluated the fire regimes of two recently protected areas in Madagascar (Ibity and Itremo NPA) and one in Brazil (Serra do Cipó NP) before and after livestock exclusion and fire suppression policies. We compare the pre- and post-management fire history in these areas and analyze differences in terms of total annual burned area, density of ignitions, burn scar size distribution, fire return period and seasonal fire distribution. More than 90% of total park areas were burned at least once during the studied period, for all parks. We observed a significant reduction in the number of ignitions for Ibity NPA and Serra do Cipó NP after livestock exclusion and active fire suppression, but no significant change in total burned area for each protected area. We also observed a seasonal shift in burning, with fires happening later in the fire season (October-November) after management intervention. However, the protected areas in Madagascar had shorter fire return intervals (3.23 and 1.82 years) than those in Brazil (7.91 years). Our results demonstrate that fire exclusion is unattainable, and probably unwarranted in tropical grassland conservation areas, but show how human intervention in fire and vegetation patterns can alter various aspects of the fire regimes. This information can help with formulating realistic and effective fire management policies in these valuable conservation areas. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Monitoring of fire incidences in vegetation types and Protected Areas of India: Implications on carbon emissions

    NASA Astrophysics Data System (ADS)

    Reddy, C. Sudhakar; Padma Alekhya, V. V. L.; Saranya, K. R. L.; Athira, K.; Jha, C. S.; Diwakar, P. G.; Dadhwal, V. K.

    2017-02-01

    Carbon emissions released from forest fires have been identified as an environmental issue in the context of global warming. This study provides data on spatial and temporal patterns of fire incidences, burnt area and carbon emissions covering natural vegetation types (forest, scrub and grassland) and Protected Areas of India. The total area affected by fire in the forest, scrub and grasslands have been estimated as 48765.45, 6540.97 and 1821.33 km 2, respectively, in 2014 using Resourcesat-2 AWiFS data. The total CO 2 emissions from fires of these vegetation types in India were estimated to be 98.11 Tg during 2014. The highest emissions were caused by dry deciduous forests, followed by moist deciduous forests. The fire season typically occurs in February, March, April and May in different parts of India. Monthly CO 2 emissions from fires for different vegetation types have been calculated for February, March, April and May and estimated as 2.26, 33.53, 32.15 and 30.17 Tg, respectively. Protected Areas represent 11.46% of the total natural vegetation cover of India. Analysis of fire occurrences over a 10-year period with two types of sensor data, i.e., AWiFS and MODIS, have found fires in 281 (out of 614) Protected Areas of India. About 16.78 Tg of CO 2 emissions were estimated in Protected Areas in 2014. The natural vegetation types of Protected Areas have contributed for burnt area of 17.3% and CO 2 emissions of 17.1% as compared to total natural vegetation burnt area and emissions in India in 2014. 9.4% of the total vegetation in the Protected Areas was burnt in 2014. Our results suggest that Protected Areas have to be considered for strict fire management as an effective strategy for mitigating climate change and biodiversity conservation.

  2. Reserves Protect against Deforestation Fires in the Amazon

    PubMed Central

    Adeney, J. Marion; Christensen, Norman L.; Pimm, Stuart L.

    2009-01-01

    Background Reserves are the principal means to conserve forests and biodiversity, but the question of whether reserves work is still debated. In the Amazon, fires are closely linked to deforestation, and thus can be used as a proxy for reserve effectiveness in protecting forest cover. We ask whether reserves in the Brazilian Amazon provide effective protection against deforestation and consequently fires, whether that protection is because of their location or their legal status, and whether some reserve types are more effective than others. Methodology/Principal Findings Previous work has shown that most Amazonian fires occur close to roads and are more frequent in El Niño years. We quantified these relationships for reserves and unprotected areas by examining satellite-detected hot pixels regressed against road distance across the entire Brazilian Amazon and for a decade with 2 El Niño-related droughts. Deforestation fires, as measured by hot pixels, declined exponentially with increasing distance from roads in all areas. Fewer deforestation fires occurred within protected areas than outside and the difference between protected and unprotected areas was greatest near roads. Thus, reserves were especially effective at preventing these fires where they are known to be most likely to burn; but they did not provide absolute protection. Even within reserves, at a given distance from roads, there were more deforestation fires in regions with high human impact than in those with low impact. The effect of El Niño on deforestation fires was greatest outside of reserves and near roads. Indigenous reserves, limited-use reserves, and fully protected reserves all had fewer fires than outside areas and did not appear to differ in their effectiveness. Conclusions/Significance Taking time, regional factors, and climate into account, our results show that reserves are an effective tool for curbing destructive burning in the Amazon. PMID:19352423

  3. 33 CFR 149.418 - What fire protection system must a helicopter fueling facility have?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... a helicopter fueling facility have? 149.418 Section 149.418 Navigation and Navigable Waters COAST... protection system must a helicopter fueling facility have? In addition to the portable fire extinguishers required under table 149.409, each helicopter fueling facility must have a fire protection system complying...

  4. 33 CFR 149.418 - What fire protection system must a helicopter fueling facility have?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... a helicopter fueling facility have? 149.418 Section 149.418 Navigation and Navigable Waters COAST... protection system must a helicopter fueling facility have? In addition to the portable fire extinguishers required under table 149.409, each helicopter fueling facility must have a fire protection system complying...

  5. 33 CFR 149.418 - What fire protection system must a helicopter fueling facility have?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... a helicopter fueling facility have? 149.418 Section 149.418 Navigation and Navigable Waters COAST... protection system must a helicopter fueling facility have? In addition to the portable fire extinguishers required under Table 149.409 of this part, each helicopter fueling facility must have a fire protection...

  6. 33 CFR 149.418 - What fire protection system must a helicopter fueling facility have?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... a helicopter fueling facility have? 149.418 Section 149.418 Navigation and Navigable Waters COAST... protection system must a helicopter fueling facility have? In addition to the portable fire extinguishers required under Table 149.409 of this part, each helicopter fueling facility must have a fire protection...

  7. 33 CFR 149.418 - What fire protection system must a helicopter fueling facility have?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... a helicopter fueling facility have? 149.418 Section 149.418 Navigation and Navigable Waters COAST... protection system must a helicopter fueling facility have? In addition to the portable fire extinguishers required under table 149.409, each helicopter fueling facility must have a fire protection system complying...

  8. 46 CFR 28.825 - Excess fire detection and protection equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Excess fire detection and protection equipment. 28.825... equipment. Instead of meeting the requirements of § 28.155, each vessel to which this subpart applies must meet the following requirements: (a) Installation of fire detection and protection equipment in excess...

  9. Pathological Studies on the Protective Effect of a Macrolide Antibiotic, Roxithromycin, against Sulfur Mustard Inhalation Toxicity in a Rat Model

    DTIC Science & Technology

    2011-01-01

    placed in a water-jacketed (37C) glass vapor generator custom fabri - cated by Atmar Glass (Kennett Square, PA). Spontaneously breathing rats were...bronchiectasis, and pul- monary fibrosis (Emad and Rezaian 1997). Macrolide antibio- tics have shown effectiveness in a variety of chronic respiratory diseases ...observed in clinical studies of chronic inflammatory airway diseases (e.g., DPB) after long-term treatment with low dose of macrolides (Rubin 2004). For

  10. Lightweight Tanks for Storing Liquefied Natural Gas

    NASA Technical Reports Server (NTRS)

    DeLay, Tom

    2008-01-01

    Single-walled, jacketed aluminum tanks have been conceived for storing liquefied natural gas (LNG) in LNG-fueled motor vehicles. Heretofore, doublewall steel tanks with vacuum between the inner and outer walls have been used for storing LNG. In comparison with the vacuum- insulated steel tanks, the jacketed aluminum tanks weigh less and can be manufactured at lower cost. Costs of using the jacketed aluminum tanks are further reduced in that there is no need for the vacuum pumps heretofore needed to maintain vacuum in the vacuum-insulated tanks.

  11. Rx fire laws: tools to protect fire: the `ecological imperative?

    Treesearch

    Dale Wade; Steven Miller; Johnny Stowe; James Brenner

    2006-01-01

    The South is the birthplace of statutes and ordinances that both advocate and protect the cultural heritage of woods burning, which has been practiced in this region uninterrupted for more than 10,000 years. We present a brief overview of fire use in the South and discuss why most southern states recognized early on that periodic fire was necessary to sustain fire...

  12. 30 CFR 75.1107-8 - Fire suppression devices; extinguishant supply systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-8... liquid chemical to protect attended equipment shall: (1) Be maintained at a pressure consistent with the...

  13. 30 CFR 75.1107-8 - Fire suppression devices; extinguishant supply systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-8... liquid chemical to protect attended equipment shall: (1) Be maintained at a pressure consistent with the...

  14. 14 CFR 25.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Fire Protection § 25..., including electrical faults, overheating of equipment, and malfunctioning of protective devices. (4) Means...

  15. Improvement of Workwear Clothing for Army

    NASA Astrophysics Data System (ADS)

    Belakova, D.; Dabolina, I.; Baltina, I.; Zommere, G.

    2017-10-01

    The two main tasks of combat clothes are soldier's physical protection and freedom of movements [1]. This requirement shall be made with the provision of protective clothing appearance and fit, as well as a suitable choice of material [2]. The aim of the research described in an article is to find out what issues the potential end user meets with during product using (field uniform trousers and jackets) and how it would be possible to avoid it. To reach the aim, end user were interviewed using survey, prospective users were measured by non-contact Human Body 3D scanning combat clothing prototypes (field uniforms) constructive and technological solutions and properties of fabrics were analysed during research.

  16. 46 CFR 28.380 - General structural fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... accommodation space must be separated from machinery and fuel tank spaces by a fire resistant boundary which... 46 Shipping 1 2010-10-01 2010-10-01 false General structural fire protection. 28.380 Section 28..., 1991, and That Operate With More Than 16 Individuals on Board § 28.380 General structural fire...

  17. 78 FR 6133 - Agency Information Collection Activities; Submission for OMB Review; Comment Request; Fire...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-29

    ... for OMB Review; Comment Request; Fire Protection in Underground Coal Mines ACTION: Notice. SUMMARY... information collection request (ICR) revision titled, ``Fire Protection in Underground Coal Mines,'' to the... sections of part 75 require fire drills to be conducted quarterly, equipment to be tested, and a record to...

  18. Maximal physical work performance with European standard based fire-protective clothing system and equipment in relation to individual characteristics.

    PubMed

    Louhevaara, V; Ilmarinen, R; Griefahn, B; Künemund, C; Mäkinen, H

    1995-01-01

    Every fire fighter needs to wear fire-protective clothing and a self-contained breathing apparatus (SCBA) several times a year while carrying out various fire-fighting and rescue operations in hazardous work environments. The aim of the present study was to quantify the effects of a multilayer turnout suit designed to fulfil European standard EN 469 used over standardized (Nordic) clothing and with SCBA (total mass 25.9 kg) on maximal physical work performance, and to evaluate the relationship between individual characteristics and power output with the fire-protective clothing system and SCBA. The subjects were 12 healthy firemen aged 26-46 years. The range of their body mass, body fat and maximal oxygen consumption was 69-101 kg, 10-20% and 2.70-5.86 l.min-1, respectively. The maximal tests without (control) and with the fire-protective clothing system and SCBA were carried out on a treadmill in a thermoneutral environment. When compared to the control test, the decrease in the maximal power output in terms of maximal working time and walking speed averaged 25% (P < 0.001) varying from 18% to 34% with the fire-protective clothing system and SCBA. At maximum, no significant differences were found in pulmonary ventilation, absolute oxygen consumption, the respiratory exchange ratio, heart rate, systolic blood pressure, the rate-pressure product, mechanical efficiency, and the rating of perceived exertion between the tests with and without the fire-protective clothing system and SCBA. The reduction of the power output was related to the extra mass of the fire protective clothing and SCBA.(ABSTRACT TRUNCATED AT 250 WORDS)

  19. Crew Exploration Vehicle Environmental Control and Life Support Fire Protection Approach

    NASA Technical Reports Server (NTRS)

    Lewis, John F.; Barido, Richard; Tuan, George C.

    2007-01-01

    As part of preparing for the Crew Exploration Vehicle (CEV), the National Aeronautics and Space Administration (NASA) worked on developing the requirements to manage the fire risk. The new CEV poses unique challenges to current fire protection systems. The size and configuration of the vehicle resembles the Apollo capsule instead of the current Space Shuttle or the International Space Station. The smaller free air volume and fully cold plated avionic bays of the CEV requires a different approach in fire protection than the ones currently utilized. The fire protection approach discussed in this paper incorporates historical lessons learned and fire detection and suppression system design philosophy spanning from Apollo to the International Space Station. Working with NASA fire and materials experts, this approach outlines the best requirements for both the closed out area of the vehicle, such as the avionics bay, and the crew cabin area to address the unique challenges due to the size and configuration of the CEV.

  20. Mechanised spraying device a novel technology for spraying fire protective coating material in the benches of opencast coal mines for preventing spontaneous combustion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    R.V.K. Singh; V.K. Singh

    2004-10-15

    Spontaneous combustion in coal mines plays a vital role in occurrences of fire. Fire in coal, particularly in opencast mines, not only causes irreparable loss of national wealth but damages the surface structure and pollutes the environment. The problem of spontaneous combustion/fire in opencast coal benches is acute. Presently over 75% of the total production of coal in Indian mines is being carried out by opencast mining. Accordingly a mechanised spraying device has been developed for spraying the fire protective coating material for preventing spontaneous combustion in coal benches of opencast mines jointly by Central Mining Research Institute, Dhanbad andmore » M/s Signum Fire Protection (India) Pvt. Ltd., Nagpur under Science & Technology (S&T) project funded by Ministry of Coal, Govt. of India. The objective of this paper is to describe in detail about the mechanised spraying device and its application for spraying fire protective coating material in the benches of opencast coal mines for preventing spontaneous combustion/fire.« less

  1. Low velocity gunshot wounds result in significant contamination regardless of ballistic characteristics.

    PubMed

    Weinstein, Joseph; Putney, Emily; Egol, Kenneth

    2014-01-01

    Controversy exists among the orthopedic community regarding the treatment of gunshot injuries. No consistent treatment algorithm exists for treatment of low energy gunshot wound (GSW) trauma. The purpose of this study was to critically examine the wound contamination following low velocity GSW based upon bullet caliber and clothing fiber type found within the injury track. Four types of handguns were fired at ballistic gel from a 10-foot distance. Various clothing materials were applied (denim, cotton, polyester, and wool) circumferentially around the tissue agar in a loose manor. A total of 32 specimens were examined. Each caliber handgun was fired a minimum of 5 times into a gel. Regardless of bullet caliber there was gross contamination of the entire bullet track in 100% of specimens in all scenarios and for all fiber types. Furthermore, as would be expected, the degree of contamination appeared to increase as the size of the bullet increased. Low velocity GSWs result in significant contamination regardless of bullet caliber and jacket type. Based upon our results further investigation of low velocity GSW tracks is warranted. Further clinical investigation should focus on the degree to which debridement should be undertaken.

  2. 33 CFR 149.641 - What are the structural fire protection requirements for accommodation spaces and modules?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false What are the structural fire protection requirements for accommodation spaces and modules? 149.641 Section 149.641 Navigation and... national consensus standard, as that term is defined in 29 CFR 1910.2, for the structural fire protection...

  3. Zebra Mussel Chemical Control Guide, Version 2.0

    DTIC Science & Technology

    2015-07-01

    delivery systems, including potable water treatment, agriculture, industry, power generation, and fire protection. Since this invasive organism’s...delivery systems, including potable water treatment, agriculture, industry, power generation, and fire protection (Mackie and Claudi 2010). Zebra mussels...generators, pipes, valves, sensing equipment (level, flow, and pressure) and fire protection (Mackie and Claudi 2010; Prescott et al. 2014). Other USACE

  4. Motorcycle protective clothing: protection from injury or just the weather?

    PubMed

    de Rome, Liz; Ivers, Rebecca; Fitzharris, Michael; Du, Wei; Haworth, Narelle; Heritier, Stephane; Richardson, Drew

    2011-11-01

    Apart from helmets, little is known about the effectiveness of motorcycle protective clothing in reducing injuries in crashes. The study aimed to quantify the association between usage of motorcycle clothing and injury in crashes. Cross-sectional analytic study. Crashed motorcyclists (n=212, 71% of identified eligible cases) were recruited through hospitals and motorcycle repair services. Data was obtained through structured face-to-face interviews. The main outcome was hospitalization and motorcycle crash-related injury. Poisson regression was used to estimate relative risk (RR) and 95% confidence intervals for injury adjusting for potential confounders. Motorcyclists were significantly less likely to be admitted to hospital if they crashed wearing motorcycle jackets (RR=0.79, 95% CI: 0.69-0.91), pants (RR=0.49, 95% CI: 0.25-0.94), or gloves (RR=0.41, 95% CI: 0.26-0.66). When garments included fitted body armour there was a significantly reduced risk of injury to the upper body (RR=0.77, 95% CI: 0.66-0.89), hands and wrists (RR=0.55, 95% CI: 0.38-0.81), legs (RR=0.60, 95% CI: 0.40-0.90), feet and ankles (RR=0.54, 95% CI: 0.35-0.83). Non-motorcycle boots were also associated with a reduced risk of injury compared to shoes or joggers (RR=0.46, 95% CI: 0.28-0.75). No association between use of body armour and risk of fracture injuries was detected. A substantial proportion of motorcycle designed gloves (25.7%), jackets (29.7%) and pants (28.1%) were assessed to have failed due to material damage in the crash. Motorcycle protective clothing is associated with reduced risk and severity of crash related injury and hospitalization, particularly when fitted with body armour. The proportion of clothing items that failed under crash conditions indicates a need for improved quality control. While mandating usage of protective clothing is not recommended, consideration could be given to providing incentives for usage of protective clothing, such as tax exemptions for safety gear, health insurance premium reductions and rebates. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. 29 CFR 1915.501 - General provisions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... safety plan including hazards, controls, fire safety and health rules, and emergency procedures; (ii... (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard... require employers to protect all employees from fire hazards in shipyard employment, including employees...

  6. 29 CFR 1915.501 - General provisions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... safety plan including hazards, controls, fire safety and health rules, and emergency procedures; (ii... (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard... require employers to protect all employees from fire hazards in shipyard employment, including employees...

  7. 29 CFR 1915.501 - General provisions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... safety plan including hazards, controls, fire safety and health rules, and emergency procedures; (ii... (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard... require employers to protect all employees from fire hazards in shipyard employment, including employees...

  8. CANNED SLUG

    DOEpatents

    Burton, M.

    1959-02-17

    Fuel elements of the type comprised of a core of fissionable material enclosed in a jacket of nonfissionable, corrosion resistant material are presented. In this invention the fissionable core is shorter than the jacket member, to provide a void chamber in one end of the assembled element. The fissionable material is separated from the chamber by an inwardly extending portion of the jacket member containing a gas permeable wafer centrally disposed therein. The outer end of the chamber is closed bv the end of the jacket which has a rupture disk centrally disposed therein. Gases formed by the irradiation of the fissionable material pass through the porous wafer into the chanmber thereby causing a gradual increase in the pressure in the chamber. The rupture disk is designed to fail at a lower pressure than that which would rupture the jacket. Upon rupture of the disk, the gases in the chamber escape into the coolant channel and coolant enters the chamber but is prevented from coming into contact with the fissionable material by the action of the gases under pressure passing outwardly through the wafer. The ruptured fuel element may be readily detected by monitoring the reactor coolant system.

  9. Arikan and Alamouti matrices based on fast block-wise inverse Jacket transform

    NASA Astrophysics Data System (ADS)

    Lee, Moon Ho; Khan, Md Hashem Ali; Kim, Kyeong Jin

    2013-12-01

    Recently, Lee and Hou (IEEE Signal Process Lett 13: 461-464, 2006) proposed one-dimensional and two-dimensional fast algorithms for block-wise inverse Jacket transforms (BIJTs). Their BIJTs are not real inverse Jacket transforms from mathematical point of view because their inverses do not satisfy the usual condition, i.e., the multiplication of a matrix with its inverse matrix is not equal to the identity matrix. Therefore, we mathematically propose a fast block-wise inverse Jacket transform of orders N = 2 k , 3 k , 5 k , and 6 k , where k is a positive integer. Based on the Kronecker product of the successive lower order Jacket matrices and the basis matrix, the fast algorithms for realizing these transforms are obtained. Due to the simple inverse and fast algorithms of Arikan polar binary and Alamouti multiple-input multiple-output (MIMO) non-binary matrices, which are obtained from BIJTs, they can be applied in areas such as 3GPP physical layer for ultra mobile broadband permutation matrices design, first-order q-ary Reed-Muller code design, diagonal channel design, diagonal subchannel decompose for interference alignment, and 4G MIMO long-term evolution Alamouti precoding design.

  10. Resistance of eastern hardwood stems to fire injury and damage

    Treesearch

    Kevin T. Smith; Elaine Kennedy Sutherland

    2006-01-01

    This paper reviews the protective features and defensive responses of eastern hardwood species exposed to fire. Trees survive fire through protective features such as thick bark and the induced defenses of compartmentalization. Dissection of trees exposed to prescribed fire in an oak forest in southern Ohio highlights the need to distinguish between bark scorch, stem...

  11. Potential fire behavior in pine flatwood forests following three different fuel reduction techniques

    Treesearch

    Patrick Brose; Dale Wade

    2002-01-01

    A computer modeling study to determine the potential fire behavior in pine flatwood forests following three fuel hazard reduction treatments: herbicide, prescribed fire and thinning was conducted in Florida following the 1998 wildfire season. Prescribed fire provided immediate protection but this protection quickly disappeared as the rough recovered. Thinning had a...

  12. 40 CFR Appendix P to Subpart G of... - Substitutes Listed in the September 27, 2006 Final Rule, Effective November 27, 2006

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... latest edition of the NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems, for whichever... requirements. 4—The agent should be recovered from the fire protection system in conjunction with testing or... coverage related to the use of personal protective equipment (e.g., respiratory protection), fire...

  13. 40 CFR Appendix P to Subpart G of... - Substitutes Listed in the September 27, 2006 Final Rule, Effective November 27, 2006

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... latest edition of the NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems, for whichever... requirements. 4—The agent should be recovered from the fire protection system in conjunction with testing or... coverage related to the use of personal protective equipment (e.g., respiratory protection), fire...

  14. 40 CFR Appendix P to Subpart G of... - Substitutes Listed in the September 27, 2006 Final Rule, Effective November 27, 2006

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... latest edition of the NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems, for whichever... requirements. 4—The agent should be recovered from the fire protection system in conjunction with testing or... coverage related to the use of personal protective equipment (e.g., respiratory protection), fire...

  15. Synthesis and evaluation of borates derived from boric acid for fire and decay protections

    Treesearch

    George Chen

    1999-01-01

    The degradation of wood by decay, fire and UV constitutes the three major losses of wood products in use. Commercial wood preservatives including chromated copper arsenate(CCA) and pentachlorophenol(penta) can only protect wood from decay. Dual protections of wood against decay and fire or decay and UV if acheivable are more desirable. Many phosphorus and boron...

  16. Laboratory investigation of fire protection coatings for creosote-treated timber railroad bridges

    Treesearch

    Carol A. Clausen; Robert H. White; James P. Wacker; Stan T. Lebow; Mark A. Dietenberger; Samuel L. Zelinka; Nicole M. Stark

    2014-01-01

    As the incidence of timber railroad bridge fires increases, so has the need to develop protective measures to reduce the risk from accidental ignitions primarily caused by hot metal objects. Of the six barrier treatments evaluated in the laboratory for their ability to protect timbers from fires sourced with ignition from hot metal objects only one intumescent coating...

  17. JACKETED FISSIONABLE MEMBER

    DOEpatents

    Boller, E.R.; Robinson, J.W.

    1960-09-13

    A fuel element design for a nuclear reactor is presented. The fuel element comprises a cylindrical fuel body having a portion of smaller diameter at each end thereof with an annular flange at the extreme ends of these portions of smaller diameter. An end cap fits over the ends of the fuel body and has an internal annular groove adapted to receive the flange. The fuel body and end caps are disposed in a cup-shaped jacket, a closure disc completing the enclosure of the fuel body, and tht caps are bonded over their entire periphery to the jacket.

  18. Splice connector with internal heat transfer jacket

    DOEpatents

    Silva, Frank A.; Mayer, Robert W.

    1977-01-01

    A heat transfer jacket is placed over the terminal portions of the conductors of a pair of high voltage cables which are connected in a splice connection wherein a housing surrounds the connected conductor portions, the heat transfer jacket extending longitudinally between the confronting ends of a pair of adaptor sleeves placed upon the insulation of the cables to engage and locate the adaptor sleeves relative to one another, and laterally between the conductors and the housing to provide a path of relatively high thermal conductivity between the connected conductor portions and the housing.

  19. Determinants of venom-specific IgE antibody concentration during long-term wasp venom immunotherapy.

    PubMed

    Pravettoni, Valerio; Piantanida, Marta; Primavesi, Laura; Forti, Stella; Pastorello, Elide A

    2015-01-01

    Venom immunotherapy (VIT) is an effective treatment for subjects with systemic allergic reactions (SR) to Hymenoptera stings, however there are few studies concerning the relevance of the venom specific IgE changes to decide about VIT cessation. We assessed IgE changes during a 5-year VIT, in patients stung and protected within the first 3 years (SP 0-3) or in the last 2 years (SP 3-5), and in patients not stung (NoS), to evaluate possible correlations between IgE changes and clinical protection. Yellow jacket venom (YJV)-allergic patients who completed 5 years of VIT were retrospectively evaluated. Baseline IgE levels and after the 3rd and the 5th year of VIT were determined; all patients were asked about field stings and SRs. A total of 232 YJV-allergic patients were included and divided into the following groups: 84 NoS, 72 SP 0-3 and 76 SP 3-5. IgE levels decreased during VIT compared to baseline values (χ(2) = 346.029, p < 0.001). Recent vespid stings accounted for significantly higher IgE levels despite clinical protection. IgE levels after 5 years of VIT correlated significantly with Mueller grade (F = 2.778, p = 0.012) and age (F = 6.672, p = 0.002). During follow-up from 1 to 10 years after VIT discontinuation, 35.2 % of the contacted patients reported at least one field sting without SR. The yellow jacket-VIT temporal stopping criterion of 5 years duration did not result in undetectable IgE levels, despite a long-lasting protection. A mean IgE decrease from 58 to 70 % was observed, and it was less marked in elderly patients or in subjects with higher Mueller grade SR.

  20. Risks and issues in fire safety on the Space Station

    NASA Technical Reports Server (NTRS)

    Friedman, Robert

    1993-01-01

    A fire in the inhabited portion of a spacecraft is a greatly feared hazard, but fire protection in space operations is complicated by two factors. First, the spacecraft cabin is an enclosed volume, which limits the resources for fire fighting and the options for crew escape. Second, an orbiting spacecraft experiences a balance of forces, creating a near-zero-gravity (microgravity) environment that profoundly affects the characteristics of fire initiation, spread, and suppression. The current Shuttle Orbiter is protected by a fire-detection and suppression system whose requirements are derived of necessity from accepted terrestrial and aircraft standards. While experience has shown that Shuttle fire safety is adequate, designers recognize that improved systems to respond specifically to microgravity fire characteristics are highly desirable. Innovative technology is particularly advisable for the Space Station, a forthcoming space community with a complex configuration and long-duration orbital missions, in which the effectiveness of current fire-protection systems is unpredictable. The development of risk assessments to evaluate the probabilities and consequences of fire incidents in spacecraft are briefly reviewed. It further discusses the important unresolved issues and needs for improved fire safety in the Space Station, including those of material selection, spacecraft atmospheres, fire detection, fire suppression, and post-fire restoration.

  1. 46 CFR 95.17-25 - Additional protection required.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... FIRE PROTECTION EQUIPMENT Foam Extinguishing Systems, Details § 95.17-25 Additional protection required. (a) In order that any residual fires above the floor plates may be extinguished when a foam system is...

  2. 46 CFR 95.17-25 - Additional protection required.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... FIRE PROTECTION EQUIPMENT Foam Extinguishing Systems, Details § 95.17-25 Additional protection required. (a) In order that any residual fires above the floor plates may be extinguished when a foam system is...

  3. 40 CFR Appendix J to Subpart G of... - Substitutes listed in the January 29, 2002 Final Rule, effective April 1, 2002

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... from the fire protection system in conjunction with testing or servicing, and recycled for later use or... protective equipment (e.g., respiratory protection), fire protection, hazard communication, worker training...

  4. 40 CFR Appendix J to Subpart G of... - Substitutes listed in the January 29, 2002 Final Rule, effective April 1, 2002

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... from the fire protection system in conjunction with testing or servicing, and recycled for later use or... protective equipment (e.g., respiratory protection), fire protection, hazard communication, worker training...

  5. 40 CFR Appendix J to Subpart G of... - Substitutes listed in the January 29, 2002 Final Rule, effective April 1, 2002

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... from the fire protection system in conjunction with testing or servicing, and recycled for later use or... protective equipment (e.g., respiratory protection), fire protection, hazard communication, worker training...

  6. Protective shield for an instrument probe

    DOEpatents

    Johnsen, Howard A.; Ross, James R.; Birtola, Sal R.

    2004-10-26

    A shield is disclosed that is particularly useful for protecting exposed optical elements at the end of optical probes used in the analysis of hazardous emissions in and around an industrial environment from the contaminating effects of those emissions. The instant invention provides a hood or cowl in the shape of a right circular cylinder that can be fitted over the end of such optical probes. The hood provides a clear aperture through which the probe can perform unobstructed analysis. The probe optical elements are protected from the external environment by passing a dry gas through the interior of the hood and out through the hood aperture in sufficient quantity and velocity to prevent any significant mixing between the internal and external environments. Additionally, the hood is provided with a cooling jacket to lessen the potential for damaging the probe due to temperature excursions.

  7. Development of a Midscale Test for Flame Resistant Protection

    DTIC Science & Technology

    2016-08-01

    Evaluation of Flame Resistant Clothing for Protection against Fire Simulations Using an Instrumented Manikin, which provides both radiant and convective heat...TEST METHODS FIRE RESISTANT MATERIALS TORCHES SIMULATION TEST EQUIPMENT FLAME RESISTANT CLOTHING PERFORMANCE(ENGINEERING... fabric during a fire , and even after the fire has been extinguished. The best known full scale transmitted heat flux test is the "ASTM F1930

  8. 41 CFR 102-80.85 - Are Federally owned and leased buildings exempt from State and local code requirements in fire...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... leased buildings exempt from State and local code requirements in fire protection? 102-80.85 Section 102... Fire Prevention State and Local Codes § 102-80.85 Are Federally owned and leased buildings exempt from State and local code requirements in fire protection? Federally owned buildings are generally exempt...

  9. 41 CFR 102-80.85 - Are Federally owned and leased buildings exempt from State and local code requirements in fire...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... leased buildings exempt from State and local code requirements in fire protection? 102-80.85 Section 102... Fire Prevention State and Local Codes § 102-80.85 Are Federally owned and leased buildings exempt from State and local code requirements in fire protection? Federally owned buildings are generally exempt...

  10. 41 CFR 102-80.85 - Are Federally owned and leased buildings exempt from State and local code requirements in fire...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... leased buildings exempt from State and local code requirements in fire protection? 102-80.85 Section 102... Fire Prevention State and Local Codes § 102-80.85 Are Federally owned and leased buildings exempt from State and local code requirements in fire protection? Federally owned buildings are generally exempt...

  11. 41 CFR 102-80.85 - Are Federally owned and leased buildings exempt from State and local code requirements in fire...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... leased buildings exempt from State and local code requirements in fire protection? 102-80.85 Section 102... Fire Prevention State and Local Codes § 102-80.85 Are Federally owned and leased buildings exempt from State and local code requirements in fire protection? Federally owned buildings are generally exempt...

  12. 41 CFR 102-80.85 - Are Federally owned and leased buildings exempt from State and local code requirements in fire...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... leased buildings exempt from State and local code requirements in fire protection? 102-80.85 Section 102... Fire Prevention State and Local Codes § 102-80.85 Are Federally owned and leased buildings exempt from State and local code requirements in fire protection? Federally owned buildings are generally exempt...

  13. 10 CFR 50.48 - Fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... suppression systems; and (iii) The means to limit fire damage to structures, systems, or components important...) Standard 805, “Performance-Based Standard for Fire Protection for Light Water Reactor Electric Generating... pressurized-water reactors (PWRs) is not permitted. (iv) Uncertainty analysis. An uncertainty analysis...

  14. 10 CFR 50.48 - Fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... suppression systems; and (iii) The means to limit fire damage to structures, systems, or components important...) Standard 805, “Performance-Based Standard for Fire Protection for Light Water Reactor Electric Generating... pressurized-water reactors (PWRs) is not permitted. (iv) Uncertainty analysis. An uncertainty analysis...

  15. Risk reduction in road and rail LPG transportation by passive fire protection.

    PubMed

    Paltrinieri, Nicola; Landucci, Gabriele; Molag, Menso; Bonvicini, Sarah; Spadoni, Gigliola; Cozzani, Valerio

    2009-08-15

    The potential reduction of risk in LPG (Liquefied Petroleum Gas) road transport due to the adoption of passive fire protections was investigated. Experimental data available for small scale vessels fully engulfed by a fire were extended to real scale road and rail tankers through a finite elements model. The results of mathematical simulations of real scale fire engulfment scenarios that may follow accidents involving LPG tankers proved the effectiveness of the thermal protections in preventing the "fired" BLEVE (Boiling Liquid Expanding Vapour Explosion) scenario. The presence of a thermal coating greatly increases the "time to failure", providing a time lapse that in the European experience may be considered sufficient to allow the start of effective mitigation actions by fire brigades. The results obtained were used to calculate the expected reduction of individual and societal risk due to LPG transportation in real case scenarios. The analysis confirmed that the introduction of passive fire protections turns out in a significant reduction of risk, up to an order of magnitude in the case of individual risk and of about 50% if the expectation value is considered. Thus, the adoption of passive fire protections, not compulsory in European regulations, may be an effective technical measure for risk reduction, and may contribute to achieve the control of "major accidents hazards" cited by the European legislation.

  16. Mobile communication jacket for people with severe speech impairment.

    PubMed

    Lampe, Renée; Blumenstein, Tobias; Turova, Varvara; Alves-Pinto, Ana

    2018-04-01

    Cerebral palsy is a movement disorder caused by damage to motor control areas of the developing brain during early childhood. Motor disorders can also affect the ability to produce clear speech and to communicate. The aim of this study was to develop and to test a prototype of an assistive tool with an embedded mobile communication device to support patients with severe speech impairments. A prototype was developed by equipping a cycling jacket with a display, a small keyboard, a LED and an alarm system, all controlled by a microcontroller. Functionality of the prototype was tested in six participants (aged 7-20 years) with cerebral palsy and global developmental disorder and three healthy persons. A patient questionnaire consisting of seven items was used as an evaluation tool. A working prototype of the communication jacket was developed and tested. The questionnaire elicited positive responses from participants. Improvements to correct revealed weaknesses were proposed. Enhancements like voice output of pre-selected phrases and enlarged display were implemented. Integration in a jacket makes the system mobile and continuously available to the user. The communication jacket may be of great benefit to patients with motor and speech impairments. Implications for Rehabilitation The communication jacket developed can be easily used by people with movement and speech impairment. All technical components are integrated in a garment and do not have to be held with the hands or transported separately. The system is adaptable to individual use. Both expected and unexpected events can be dealt with, which contributes to the quality of life and self-fulfilment.

  17. Non destructive testing of soft body armor

    NASA Astrophysics Data System (ADS)

    Bhise, Karan

    Pristine bullet proof vests are extremely effective at halting pre-determined projectile threats and have saved over 3000 lives. However, the effectiveness of these vests to halt a bullet is seen to decrease over time.Owing to the importance of bullet proof vests over a period of time, tests to determine their effectiveness have been carried out on every batch of vests at the time of inception and at certain time intervals by shooting a bullet through them. A few vests from every batch are picked up and shot at to check for bullet penetration during this process while these results are extrapolated onto the other vests from the batch.One of the main issues with this method is the fact that testing a few jackets among a large set of jackets does not guarantee the safety of every jacket in the entire batch.Further the jackets that are shot-at have the possibility of undergoing substantial damage during the process thus compromising its safety rendering them unsafe for future use.As the vest penetration phenomenon is extremely complex too, there arose a need for a better testing procedure that could not only help ensure more safety, but also save time and money.The new testing procedure proposed a non-destructive evaluation of the jackets that would solve the issues previous faced in testing the vests. This would lead to the building of a portable set up which could be carried to any location to test jackets in a matter of minutes thus saving time and money.

  18. Micro-CT features of intermediate gunshot wounds covered by textiles.

    PubMed

    Giraudo, Chiara; Fais, Paolo; Pelletti, Guido; Viero, Alessia; Miotto, Diego; Boscolo-Berto, Rafael; Viel, Guido; Montisci, Massimo; Cecchetto, Giovanni; Ferrara, Santo Davide

    2016-09-01

    The analysis of gunshot residue (GSR) on the clothing and the underlying skin of the victim may play an important role in the reconstruction of the shooting incident. The aim of the present study was to test micro-computed tomography (micro-CT) for the analysis of firearm wounds experimentally produced on human skin covered by textiles. Firing trials were performed on 60 sections of human calves enveloped by a single layer of fabric (cotton or jeans or leather or nylon) and 15 controls consisting of bare calves. Experimental firings were conducted in a ballistic laboratory at three different muzzle-to-target distances (5, 15, and 30 cm), using a .32 ACP pistol (Beretta Mod. 81) loaded with full-jacketed bullets coming from the same production lot (7.65 × 17 mm, Browning SR). The visual inspection revealed the classic pattern of GSR distribution on the fabrics and the skin of control samples, while only a dark ring around the entrance lesion was identified on the skin beneath the fabrics. Micro-CT analysis showed the presence of radiopaque material on all entrance wounds, with a statistically significant difference between cases and controls. No differences were found among specimens covered by fabrics, with regard to the firing distance and the type of clothing. No GSR-like deposits were detected in exit wounds. Our results suggest that micro-CT analysis may be a useful screening tool for differentiating entry from exit gunshot wounds when the covering textiles are contaminated, damaged, or missing.

  19. Reusable Surface Insulation

    NASA Technical Reports Server (NTRS)

    1997-01-01

    Advanced Flexible Reusable Surface Insulation, developed by Ames Research Center, protects the Space Shuttle from the searing heat that engulfs it on reentry into the Earth's atmosphere. Initially integrated into the Space Shuttle by Rockwell International, production was transferred to Hi-Temp Insulation Inc. in 1974. Over the years, Hi-Temp has created many new technologies to meet the requirements of the Space Shuttle program. This expertise is also used commercially, including insulation blankets to cover aircrafts parts, fire barrier material to protect aircraft engine cowlings and aircraft rescue fire fighter suits. A Fire Protection Division has also been established, offering the first suit designed exclusively by and for aircraft rescue fire fighters. Hi-Temp is a supplier to the Los Angeles City Fire Department as well as other major U.S. civil and military fire departments.

  20. Spinoff from a Mooncraft Technology

    NASA Technical Reports Server (NTRS)

    1988-01-01

    Avco Specialty Materials' Chartek III fireproofing provides longterm fire protection for structural steel in high risk industrial applications such as structural conduits, pipes and valves of offshore platforms, and storage tanks used in hydrocarbon processing industry. In the presence of fire, Chartek III fire-proofing provides two kinds of protection. One of them is ablation, technique used on Apollo involving dissipation of heat by burnoff. The other is called intumescence or swelling. Heat causes the Chartek coating to swell to a thickness six times greater than when it was applied forming a protective blanket of char that retards transfer of heat to the steel structure. Mesh reinforcement keeps the char intact and reduces metal fatigue. Chartek provides fire protection for as much as two or three hours depending on the type of fire and the thickness of the coating applied.

  1. Fire Rescue Exercise

    NASA Image and Video Library

    2014-03-06

    CAPE CANAVERAL, Fla. - Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida participate in a training exercise at the Shuttle Landing Facility. Firefighters, wearing protective gear, use hoses to put out a fire burning close to a mock-up of a small plane. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett

  2. Fire Rescue Exercise

    NASA Image and Video Library

    2014-03-06

    CAPE CANAVERAL, Fla. - Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida participate in a training exercise at the Shuttle Landing Facility. Firefighters, wearing protective gear, use hoses to put out a fire burning near the mock-up of a small plane. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett

  3. Fire Rescue Exercise

    NASA Image and Video Library

    2014-03-06

    CAPE CANAVERAL, Fla. - Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida participate in a training exercise at the Shuttle Landing Facility. Firefighters, wearing protective gear, use hoses to put out a fire burning on a mock-up of a small plane. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett

  4. Fire Rescue Exercise

    NASA Image and Video Library

    2014-03-06

    CAPE CANAVERAL, Fla. - During a training exercise, Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida use hoses to put out a fire burning on a mock-up of a small plane at the Shuttle Landing Facility. They are wearing protective gear for the training exercise. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett

  5. Fire Rescue Exercise

    NASA Image and Video Library

    2014-03-06

    CAPE CANAVERAL, Fla. - Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida participate in a training exercise at the Shuttle Landing Facility. Firefighters use a fire truck to put out a fire burning close to a mock-up of a small plane and a truck. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett

  6. Alternative approach for fire suppression of class A, B and C fires in gloveboxes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosenberger, Mark S; Tsiagkouris, James A

    2011-02-10

    Department of Energy (DOE) Orders and National Fire Protection Association (NFPA) Codes and Standards require fire suppression in gloveboxes. Several potential solutions have been and are currently being considered at Los Alamos National Laboratory (LANL). The objective is to provide reliable, minimally invasive, and seismically robust fire suppression capable of extinguishing Class A, B, and C fires; achieve compliance with DOE and NFPA requirements; and provide value-added improvements to fire safety in gloveboxes. This report provides a brief summary of current approaches and also documents the successful fire tests conducted to prove that one approach, specifically Fire Foe{trademark} tubes, ismore » capable of achieving the requirement to provide reliable fire protection in gloveboxes in a cost-effective manner.« less

  7. Fire weather in western Oregon and western Washington in 1952 compared with other years.

    Treesearch

    Owen P. Cramer

    1953-01-01

    How did the potential burning conditions of the 1952 fire season compare with those of previous years? The answer is important to those who protect forests from fire. Knowing the relative severity of the burning conditions will help them judge the effectiveness of their fire protection programs. This paper reports ratings of the weather factors most closely related to...

  8. Validation and Verification (V and V) Testing on Midscale Flame Resistant (FR) Test Method

    DTIC Science & Technology

    2016-12-16

    Method for Evaluation of Flame Resistant Clothing for Protection against Fire Simulations Using an Instrumented Manikin. Validation and...complement (not replace) the capabilities of the ASTM F1930 Standard Test Method for Evaluation of Flame Resistant Clothing for Protection against Fire ...Engineering Center (NSRDEC) to complement the ASTM F1930 Standard Test Method for Evaluation of Flame Resistant Clothing for Protection against Fire

  9. Test results: Halon 1301 versus water sprinkler fire protection for essential electronic equipment

    NASA Astrophysics Data System (ADS)

    Reichelt, E. F.; Walker, J. L.; Vickers, R. N.; Kwan, A. J.

    1982-07-01

    This report describes results of testing two contending extinguishants, Halon 1301 and water, for fire protection of essential electronic equipment. A series of controlled fires in a facility housing an operational electronic data processing system sought to establish immediate and long term effects of exposure of sensitive electronic equipment and stored data to fire extinguishment atmospheres. Test results lead to the conclusion that Halon 1301 is superior to water as an extinguishant for fires occurring in essential electronic equipment installations.

  10. Interdigital Capacitance Local Non-Destructive Examination of Nuclear Power Plant Cable for Aging Management Programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glass, Samuel W.; Fifield, Leonard S.; Bowler, Nicola

    This Pacific Northwest National Laboratory milestone report describes progress to date on the investigation of non-destructive test methods focusing on local cable insulation and jacket testing using an interdigital capacitance (IDC) approach. Earlier studies have assessed a number of non-destructive examination (NDE) methods for bulk, distributed, and local cable tests. A typical test strategy is to perform bulk assessments of the cable response using dielectric spectroscopy, Tan , or partial discharge followed by distributed tests like time domain reflectometry or frequency domain reflectometry to identify the most likely defect location followed by a local test that can include visual inspection,more » indenter modulus tests, or Fourier Transform Infrared Spectroscopy (FTIR) or Near Infrared Spectroscopy FTIR (FTNIR). If a cable is covered with an overlaying jacket, the jacket’s condition is likely to be more severely degraded than the underlying insulation. None of the above local test approaches can be used to evaluate insulation beneath a cable jacket. Since the jacket’s function is neither structural nor electrical, a degraded jacket may not have any significance regarding the cable’s performance or suitability for service. IDC measurements offer a promising alternative or complement to these local test approaches including the possibility to test insulation beneath an overlaying jacket.« less

  11. Expected damages of retrofitted bridges with RC jacketing

    NASA Astrophysics Data System (ADS)

    Montes, O.; Jara, J. M.; Jara, M.; Olmos, B. A.

    2015-07-01

    The bridge infrastructure in many countries of the world consists of medium span length structures built several decades ago and designed for very low seismic forces. Many of them are reinforced concrete structures that according to the current code regulations have to be rehabilitated to increase their seismic capacity. One way to reduce the vulnerability of the bridges is by using retrofitting techniques that increase the strength of the structure or by incorporating devices to reduce the seismic demand. One of the most common retrofit techniques of the bridges substructures is the use of RC jacketing; this research assesses the expected damages of seismically deficient medium length highway bridges retrofitted with reinforced concrete jacketing, by conducting a parametric study. We select a suite of twenty accelerograms of subduction earthquakes recorded close to the Pacific Coast in Mexico. The original structures consist of five 30 m span simple supported bridges with five pier heights of 5 m, 10 m, 15 m 20 and 25 m and the analyses include three different jacket thickness and three steel ratios. The bridges were subjected to the seismic records and non-linear time history analyses were carried out by using the OpenSEEs Plataform. Results allow selecting the reinforced concrete jacketing that better improves the expected seismic behavior of the bridge models.

  12. Jacketed lamp bulb envelope

    DOEpatents

    MacLennan, Donald A.; Turner, Brian P.; Gitsevich, Aleksandr; Bass, Gary K.; Dolan, James T.; Kipling, Kent; Kirkpatrick, Douglas A.; Leng, Yongzhang; Levin, Izrail; Roy, Robert J.; Shanks, Bruce; Smith, Malcolm; Trimble, William C.; Tsai, Peter

    2001-01-01

    A jacketed lamp bulb envelope includes a ceramic cup having an open end and a partially closed end, the partially closed end defining an aperture, a lamp bulb positioned inside the ceramic cup abutting the aperture, and a reflective ceramic material at least partially covering a portion of the bulb not abutting the aperture. The reflective ceramic material may substantially fill an interior volume of the ceramic cup not occupied by the bulb. The ceramic cup may include a structural feature for aiding in alignment of the jacketed lamp bulb envelope in a lamp. The ceramic cup may include an external flange about a periphery thereof. One example of a jacketed lamp bulb envelope includes a ceramic cup having an open end and a closed end, a ceramic washer covering the open end of the ceramic cup, the washer defining an aperture therethrough, a lamp bulb positioned inside the ceramic cup abutting the aperture, and a reflective ceramic material filling an interior volume of the ceramic cup not occupied by the bulb. A method of packing a jacketed lamp bulb envelope of the type comprising a ceramic cup with a lamp bulb disposed therein includes the steps of filling the ceramic cup with a flowable slurry of reflective material, and applying centrifugal force to the cup to pack the reflective material therein.

  13. 29 CFR 1915.509 - Definitions applicable to this subpart.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... harmful. Hose systems—fire protection systems consisting of a water supply, approved fire hose, and a... fire protection system consisting of piping and hose connections used to supply water to approved hose... influence shipyard employment (such as mail delivery or office supply services). Dangerous atmosphere—an...

  14. 49 CFR 176.315 - Fire protection requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Detailed Requirements for Class 3 (Flammable) and Combustible Liquid Materials § 176.315 Fire protection... (flammable) or combustible liquid for which it is required. Each fire extinguisher must be accessible to the... (flammable) and combustible liquids stowage areas must be fitted with an approved combination solid stream...

  15. Fire Protection. Honeywell Planning Guide.

    ERIC Educational Resources Information Center

    Honeywell, Inc., Minneapolis, Minn.

    A general discussion of fire alarms and protection is provided by a manufacturer of automated monitoring and control systems. Background information describes old and new fire alarm systems, comparing system components, wage savings, and cost analysis. Different kinds of automatic systems are listed, including--(1) local system, (2) auxiliary…

  16. Very high efficacy electrodeless high intensity discharge lamps

    DOEpatents

    Johnson, Peter D.

    1987-01-01

    An electrodeless arc lamp comprises an outer jacket hermetically sealing and thermally protecting an arc tube inside which has an upwardly convex bottom center section. The absence of chemically reactive electrode material makes it possible to use metal halides other than iodides. The tube contains chlorides, bromides or a mixture thereof of scandium and sodium in a nearly equimolar relationship in addition to mercury and an inert gas. Good color balance can be obtained at reduced reservoir temperature and with less power loss. Reduction in wall temperature makes it possible to attain longer lamp life.

  17. Very high efficacy electrodeless high intensity discharge lamps

    DOEpatents

    Johnson, P.D.

    1985-10-03

    An electrodeless arc lamp comprises an outer jacket hermetically sealing and thermally protecting an arc tube inside which has an upwardly convex bottom center section. The absence of chemically reactive electrode material makes it possible to use metal halides other than iodides. The tube contains chlorides, bromides or a mixture thereof of scandium and sodium in a nearly equimolar relationship in addition to mercury and an inert gas. Good color balance can be obtained at reduced reservoir temperature and with less power loss. Reduction in wall temperature makes it possible to attain longer lamp life.

  18. Division of Forestry Fire and Aviation Program

    Science.gov Websites

    Conservation Education Timber Management Wildland Fire & Aviation Burn Permits Firewise Alaska Brochure (PDF) Fire Management Plans Fire Assignments Annual Fire Statistics Fire Terms Glossary Incident Business Management Grants Become an Alaska Firewise Community Community Wildland Fire Protection Plans

  19. Fire in the Shop!

    ERIC Educational Resources Information Center

    Campbell, Clifton P.; Buchanan, Joseph P.

    1977-01-01

    Fire emergency preparedness measures to take to prevent school fires and to protect against injury and minimize damage when fire does occur are presented. Includes fire safety practices, extinguishers for different classes of fires and their use, and the need for fire safety training in schools. (MF)

  20. A Combined Water-Bromotrifluoromethane Crash-Fire Protection System for a T-56 Turbopropeller Engine

    NASA Technical Reports Server (NTRS)

    Campbell, John A.; Busch, Arthur M.

    1959-01-01

    A crash-fire protection system is described which will suppress the ignition of crash-spilled fuel that may be ingested by a T-56 turbo-propeller engine. This system includes means for rapidly extinguishing the combustor flame, means for cooling and inerting with water the hot engine parts likely to ignite engine ingested fuel, and means for blanketing with bromotrifluoromethane massive metal parts that may reheat after the engine stops rotating. Combustion-chamber flames were rapidly extinguished at the engine fuel nozzles by a fuel shutoff and drain valve. Hot engine parts were inerted and cooled by 42 pounds of water discharged at seven engine stations. Massive metal parts that could reheat were inerted with 10 pounds of bromotrifluoromethane discharged at two engine stations. Performance trials of the crash-fire protection system were conducted by bringing the engine up to takeoff temperature, actuating the crash-fire protection system, and then spraying fuel into the engine to simulate crash-ingested fuel. No fires occurred during these trials, although fuel was sprayed into the engine from 0.3 second to 15 minutes after actuating the crash-fire protection system.

  1. 29 CFR 1926.150 - Fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... Modification of sprinkler systems to permit alterations or additional demolition should be expedited so that... each floor. (e) Fire alarm devices. (1) An alarm system, e.g., telephone system, siren, etc., shall be... 29 Labor 8 2014-07-01 2014-07-01 false Fire protection. 1926.150 Section 1926.150 Labor...

  2. 46 CFR 76.01-2 - Incorporation by reference.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Sprinkler Systems (“NFPA 13”)—76.25-1, 76.25-90. (d) Underwriters Laboratories Inc. (UL), 12 Laboratory... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION... Connections for Marine Fire Applications (“ASTM F 1121”)—76.10-10. (c) National Fire Protection Association...

  3. 29 CFR 1926.150 - Fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... Modification of sprinkler systems to permit alterations or additional demolition should be expedited so that... each floor. (e) Fire alarm devices. (1) An alarm system, e.g., telephone system, siren, etc., shall be... 29 Labor 8 2011-07-01 2011-07-01 false Fire protection. 1926.150 Section 1926.150 Labor...

  4. 29 CFR 1926.150 - Fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... Modification of sprinkler systems to permit alterations or additional demolition should be expedited so that... each floor. (e) Fire alarm devices. (1) An alarm system, e.g., telephone system, siren, etc., shall be... 29 Labor 8 2013-07-01 2013-07-01 false Fire protection. 1926.150 Section 1926.150 Labor...

  5. 46 CFR 76.01-2 - Incorporation by reference.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Sprinkler Systems (“NFPA 13”)—76.25-1, 76.25-90. (d) Underwriters Laboratories Inc. (UL), 12 Laboratory... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION... Connections for Marine Fire Applications (“ASTM F 1121”)—76.10-10. (c) National Fire Protection Association...

  6. 29 CFR 1926.150 - Fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... Modification of sprinkler systems to permit alterations or additional demolition should be expedited so that... each floor. (e) Fire alarm devices. (1) An alarm system, e.g., telephone system, siren, etc., shall be... 29 Labor 8 2012-07-01 2012-07-01 false Fire protection. 1926.150 Section 1926.150 Labor...

  7. The economic dimension of wildland fires

    Treesearch

    Armando Gonzalez-Caban

    2013-01-01

    The economic relevance of wildland fire management and protection programs is ever growing, particularly considering mounting wildfire costs and losses globally, and the justifications required for budget allocations to management and protection of forest ecosystems. However, there are major difficulties in grappling with the problem of rapidly increasing wildland fire...

  8. 36 CFR 1234.10 - What are the facility requirements for all records storage facilities?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the HVAC systems, fire alarm and fire protection systems. Manual switching between sources of service... elements are protected by a properly installed, properly maintained wet-pipe automatic sprinkler system, as... must provide documentation that the facility has a fire suppression system specifically designed to...

  9. 46 CFR 76.01-2 - Incorporation by reference.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Incorporation by reference. 76.01-2 Section 76.01-2 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION... Connections for Marine Fire Applications (“ASTM F 1121”)—76.10-10. (c) National Fire Protection Association...

  10. 78 FR 65635 - Combined Notice of Filings #1

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-01

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Combined Notice of Filings 1 Take notice... Applicants: Yellow Jacket Energy, LLC Description: Application of Yellow Jacket Energy, LLC for Authorization...: Camden County Energy Recovery Associates, Covanta Delano, Inc., Covanta Delaware Valley, L.P., Covanta...

  11. Solution of Fire Protection in Historic Buildings

    NASA Astrophysics Data System (ADS)

    Iringová, Agnes; Idunk, Róbert

    2016-12-01

    The paper introduces optimization of the functional use of renovated spaces in historic buildings in terms of fire risk. It brings assessment of fire protection in the folk house Habánsky Dvor, situated in the village of Veľké Leváre, whose function was changed into the museum. It goes into static analysis of existing load-bearing structures and assessment of their fire resistance according to Eurocodes.

  12. 33 CFR 149.419 - Can the water supply for the helicopter deck fire protection system be part of a fire water system?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Can the water supply for the helicopter deck fire protection system be part of a fire water system? 149.419 Section 149.419 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: DESIGN, CONSTRUCTION, AND EQUIPMENT...

  13. 33 CFR 149.419 - Can the water supply for the helicopter deck fire protection system be part of a fire water system?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Can the water supply for the helicopter deck fire protection system be part of a fire water system? 149.419 Section 149.419 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: DESIGN, CONSTRUCTION, AND EQUIPMENT...

  14. 33 CFR 149.419 - Can the water supply for the helicopter deck fire protection system be part of a fire water system?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Can the water supply for the helicopter deck fire protection system be part of a fire water system? 149.419 Section 149.419 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: DESIGN, CONSTRUCTION, AND EQUIPMENT...

  15. 33 CFR 149.419 - Can the water supply for the helicopter deck fire protection system be part of a fire water system?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Can the water supply for the helicopter deck fire protection system be part of a fire water system? 149.419 Section 149.419 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: DESIGN, CONSTRUCTION, AND EQUIPMENT...

  16. Alaska's State Forests

    Science.gov Websites

    Conservation Education Timber Management Wildland Fire & Aviation Burn Permits Firewise Alaska Brochure (PDF) Fire Management Plans Fire Assignments Annual Fire Statistics Fire Terms Glossary Incident Business Management Grants Become an Alaska Firewise Community Community Wildland Fire Protection Plans

  17. Fire Rescue Exercise

    NASA Image and Video Library

    2014-03-06

    CAPE CANAVERAL, Fla. - Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida participate in a training exercise at the Shuttle Landing Facility. Firefighters, wearing protective gear, use hoses to put out a fire burning near the mock-up of a small plane as another firefighter checks inside the plane. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett

  18. A Comparison Study of Offshore Wind Support Structures with Monopiles and Jackets for U.S. Waters: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Damiani, Rick; Dykes, Katherine; Scott, George

    2016-08-01

    U.S. experience in offshore wind is limited, and high costs are expected unless innovations are introduced in one or multiple aspects of the project, from the installed technology to the balance of system (BOS). The substructure is the main single component responsible for the BOS capital expenditure (CapEx) and thus one that, if improved, could yield significant levelized cost of energy (LCOE) savings. For projects in U.S. waters, multimember, lattice structures (also known as jackets) can render required stiffness for transitional water depths at potentially lower costs than monopiles (MPs). In this study, we used a systems engineering approach tomore » evaluate the LCOE of prototypical wind power plants at six locations along the eastern seaboard and the Gulf of Mexico for both types of support structures. Using a reference wind turbine and actual metocean conditions for the selected sites, we calculated loads for a parked and an operational situation, and we optimized the MP- and jacket-based support structures to minimize their overall mass. Using a suite of cost models, we then computed their associated LCOE. For all water depths, the MP-based configurations were heavier than their jacket counterparts, but the overall costs for the MPs were less than they were for jackets up to depths of slightly less than 30 m. When the associated manufacturing and installation costs were included, jackets resulted in lower LCOE for depths greater than 40 m. These results can be used by U.S. stakeholders to understand the potential for different technologies at different sites, but the methodology illustrated in this study can be further employed to analyze the effects of innovations and design choices throughout wind power plant systems.« less

  19. Travel health: a survey of life jacket designs currently in use on commercial aircraft.

    PubMed

    Bauer, Irmgard L

    2002-01-01

    Although any travel harbors potential health problems, travel across water poses the additional risk of involuntary contact with water in the event of an emergency. Studies suggest that fatal boat-related accidents have occurred due to the passengers' inability to don their life jackets. With the dramatic increase of long-haul flights, it was decided to investigate if potential safety hazards can be identified leading to similar problems in relation to the life jackets provided onboard aircraft. It was assumed that the variety of designs combined with a possible lack of attention paid to safety instructions could represent such a problem. Safety instruction cards in passengers' seat pockets usually depict the life jacket model used on a particular aircraft. Ninety-eight such safety cards from 53 airlines were analyzed and categorized to identify the range and variety of designs currently in use. Twelve different categories of life jacket models could be distinguished with some airlines using more than one model. It was also found that not all cards show a clear depiction of the models used, the cards of two airlines show two different designs on the same cards, and two other companies chose to change the model halfway through the pictured donning procedure. There is a wide variety of life jacket designs in use with the safety cards not always giving accurate instructions. This variety also has implications for the safety demonstration at the beginning of a flight. Further research is recommended into a range of topics, one being the quality and content of these instructions, and also into other personal floating devices provided for the safety of travelers in the event of an emergency over water.

  20. A comparison study of offshore wind support structures with monopiles and jackets for U.S. waters

    NASA Astrophysics Data System (ADS)

    Damiani, R.; Dykes, K.; Scott, G.

    2016-09-01

    U.S. experience in offshore wind is limited, and high costs are expected unless innovations are introduced in one or multiple aspects of the project, from the installed technology to the balance of system (BOS). The substructure is the main single component responsible for the BOS capital expenditure (CapEx) and thus one that, if improved, could yield significant levelized cost of energy (LCOE) savings. For projects in U.S. waters, multimember lattice structures (also known as jackets) can render required stiffness for transitional water depths at potentially lower costs than monopiles (MPs). In this study, we used a systems engineering approach to evaluate the LCOE of prototypical wind power plants at six locations along the eastern seaboard and the Gulf of Mexico for both types of support structures. Using a reference wind turbine and actual metocean conditions for the selected sites, we calculated loads for a parked and an operational situation, and we optimized the MP- and jacket-based support structures to minimize their overall mass. Using a suite of cost models, we then computed their associated LCOE. For all water depths, the MP-based configurations were heavier than their jacket counterparts, but the overall costs for the MPs were less than they were for jackets up to depths of slightly less than 30m. When the associated manufacturing and installation costs were included, jackets resulted in lower LCOE for depths greater than 40m. These results can be used by U.S. stakeholders to understand the potential for different technologies at different sites, but the methodology illustrated in this study can be further employed to analyze the effects of innovations and design choices throughout wind power plant systems.

Top