Development of Fire Resistant/Heat Resistant Sewing Thread
2016-03-01
Final 3. DATES COVERED (From - To) October 2014 – June 2015 4. TITLE AND SUBTITLE DEVELOPMENT OF FIRE RESISTANT /HEAT RESISTANT SEWING THREAD 5a...core to sheath ratio of 70:30 will offer a high performance, low cost sewing thread with required fire resistant /heat resistant properties. 15...Properties ............................................................................... 18 1 DEVELOPMENT OF FIRE RESISTANT /HEAT
Evren Terzi; S. Nami Kartal; Robert White; Katsumi Shinoda; Yuji Imamura
2010-01-01
In this study, the fire performance and decay resistance of solid wood and plywood treated with quaternary ammonia compounds (didecyl dimethyl ammonium chloride (DDAC) and didecyl dimethyl ammonium tetrafluoroborate (DBF)) were compared with the performance of untreated control specimens and specimens treated with common fire retardants ((monoammonium phosphate (MAP),...
Development of a Midscale Test for Flame Resistant Protection
2016-08-01
Evaluation of Flame Resistant Clothing for Protection against Fire Simulations Using an Instrumented Manikin, which provides both radiant and convective heat...TEST METHODS FIRE RESISTANT MATERIALS TORCHES SIMULATION TEST EQUIPMENT FLAME RESISTANT CLOTHING PERFORMANCE(ENGINEERING... fabric during a fire , and even after the fire has been extinguished. The best known full scale transmitted heat flux test is the "ASTM F1930
Foam composite structures. [for fire retardant airframe materials
NASA Technical Reports Server (NTRS)
Delano, C. B.; Milligan, R. J.
1976-01-01
The need to include fire resistant foams into state of the art aircraft interior paneling to increase passenger safety in aircraft fires was studied. Present efforts were directed toward mechanical and fire testing of panels with foam inclusions. Skinned foam filled honeycomb and PBI structural foams were the two constructions investigated with attention being directed toward weight/performance/cost trade-off. All of the new panels demonstrated improved performance in fire and some were lighter weight but not as strong as the presently used paneling. Continued efforts should result in improved paneling for passenger safety. In particular the simple partial filling (fire side) of state-of-the-art honeycomb with fire resistant foams with little sacrifice in weight would result in panels with increased fire resistance. More important may be the retarded rate of toxic gas evolution in the fire due to the protection of the honeycomb by the foam.
Dong, Hongying; Cao, Wanlin; Bian, Jianhui; Zhang, Jianwei
2014-01-01
In order to ascertain the fire resistance performance of recycled aggregate concrete (RAC) components with different concrete compressive strengths, four full-scaled concrete columns were designed and tested under high temperature. Two of the four specimens were constructed by normal concrete with compressive strength ratings of C20 and C30, respectively, while the others were made from recycled coarse aggregate (RCA) concrete of C30 and C40, respectively. Identical constant axial forces were applied to specimens while being subjected to simulated building fire conditions in a laboratory furnace. Several parameters from the experimental results were comparatively analyzed, including the temperature change, vertical displacement, lateral deflection, fire endurance, and failure characteristics of specimens. The temperature field of specimens was simulated with ABAQUS Software (ABAQUS Inc., Provindence, RI, USA) and the results agreed quite well with those from the experiments. Results show that the rate of heat transfer from the surface to the interior of the column increases with the increase of the concrete’s compressive strength for both RAC columns and normal concrete columns. Under the same initial axial force ratio, for columns with the same cross section, those with lower concrete compressive strengths demonstrate better fire resistance performance. The fire resistance performance of RAC columns is better than that of normal concrete columns, with the same concrete compressive strength. PMID:28788279
Dong, Hongying; Cao, Wanlin; Bian, Jianhui; Zhang, Jianwei
2014-12-08
In order to ascertain the fire resistance performance of recycled aggregate concrete (RAC) components with different concrete compressive strengths, four full-scaled concrete columns were designed and tested under high temperature. Two of the four specimens were constructed by normal concrete with compressive strength ratings of C20 and C30, respectively, while the others were made from recycled coarse aggregate (RCA) concrete of C30 and C40, respectively. Identical constant axial forces were applied to specimens while being subjected to simulated building fire conditions in a laboratory furnace. Several parameters from the experimental results were comparatively analyzed, including the temperature change, vertical displacement, lateral deflection, fire endurance, and failure characteristics of specimens. The temperature field of specimens was simulated with ABAQUS Software (ABAQUS Inc., Provindence, RI, USA) and the results agreed quite well with those from the experiments. Results show that the rate of heat transfer from the surface to the interior of the column increases with the increase of the concrete's compressive strength for both RAC columns and normal concrete columns. Under the same initial axial force ratio, for columns with the same cross section, those with lower concrete compressive strengths demonstrate better fire resistance performance. The fire resistance performance of RAC columns is better than that of normal concrete columns, with the same concrete compressive strength.
NASA Astrophysics Data System (ADS)
Nurfaidhi Rizalman, Ahmad; Tahir, Ng Seong Yap Mahmood Md; Mohammad, Shahrin
2018-03-01
Concrete filled hollow steel section column have been widely accepted by structural engineers and designers for high rise construction due to the benefits of combining steel and concrete. The advantages of concrete filled hollow steel section column include higher strength, ductility, energy absorption capacity, and good structural fire resistance. In this paper, comparison on the fire performance between circular and square concrete filled hollow steel section column is established. A three-dimensional finite element package, ABAQUS, was used to develop the numerical model to study the temperature development, critical temperature, and fire resistance time of the selected composite columns. Based on the analysis and comparison of typical parameters, the effect of equal cross-sectional size for both steel and concrete, concrete types, and thickness of external protection on temperature distribution and structural fire behaviour of the columns are discussed. The result showed that concrete filled hollow steel section column with circular cross-section generally has higher fire resistance than the square section.
T.E. Paysen; A.L. Koonce; E. Taylor; M.O. Rodriquez
2006-01-01
In May 1993, electrical resistance measurements were performed on trees in burned and unburned stands of Caribbean pine (Pinus caribaea Mor.) in north-eastern Nicaragua to determine whether tree vigor was affected by fire. An Osmose model OZ-67 Shigometer with digital readout was used to collect the sample electrical resistance data. Computer-...
Initial Burn Pan (JMTF) Testing Results
2016-03-01
of Testing and Materials (ASTM) standard for fire - resistant boom. It had not been used for over 15 years and was almost completely destroyed when...Environment Canada had produced operational guides, provided standards for fire - resistant booms and igniting techniques needed to perform offshore burns...are currently in the smoke zone; and the heat from the fire could be felt from that area. While no one was injured, some miscommunication at the
Effect Of Resistance Modification On EML Capacitor Bank Performance
2009-06-01
EFFECT OF RESISTANCE MODIFICATION ON EML CAPACITOR BANK PERFORMANCE* B. M. Huhman, J. M. Neri, T. L. Lockner1 Plasma Physics Division, Naval...development of an electromagnetic launcher ( EML ) for surface-fire support and other missions [1]. The Naval Research Laboratory has initiated a...develop and test materials for the study of barrel lifetime in electromagnetic launchers ( EML ) for surface-fire support and other missions [3]. The
Code of Federal Regulations, 2010 CFR
2010-10-01
..., etc.) shall be designed against acting as passageways for fire and smoke and representative... structural flooring assembly to perform as a barrier against under-vehicle fires. The fire resistance period... Flammability and Smoke Emission Characteristics of Materials Used in Passenger Cars and Locomotive Cabs B...
Testing and Selection of Fire-Resistant Materials for Spacecraft Use
NASA Technical Reports Server (NTRS)
Friedman, Robert; Jackson, Brian; Olson, Sandra
2000-01-01
Spacecraft fire-safety strategy emphasizes prevention, mostly through the selection of onboard items classified accord- ing to their fire resistance. The principal NASA acceptance tests described in this paper assess the flammability of materials and components under "worst-case" normal-gravity conditions of upward flame spread in controlled-oxygen atmospheres. Tests conducted on the ground, however, cannot duplicate the unique fire characteristics in the nonbuoyant low-gravity environment of orbiting spacecraft. Research shows that flammability an fire-spread rates in low gravity are sensitive to forced convection (ventilation flows) and atmospheric-oxygen concentration. These research results are helping to define new material-screening test methods that will better evaluate material performance in spacecraft.
NASA Technical Reports Server (NTRS)
Fody, Joshua M.; Daryabeigi, Kamran; Bruce, Walter E., III; Wells, John M.; Wusk, Mary E.; Calomino, Anthony M.; Miller, Steve D.
2018-01-01
Summary of highlights of the Convective Heating Improvement for Emergency Fire Shelters (CHIEFS) taskunder NASA. CHIEFS was tasked with providing the US Forest Service with an emergency fire shelter forimproved resistance to flame contact. Emphasis is on the final shelter designs at task close-out (end of FY17).
Zhang, Xin; Peng, Lei; Ni, Zhao-peng; Ni, Tian-xiao; Huang, Yi-liang; Zhou, Yang
2018-01-01
Experimental research was conducted to study the fire resistance of steel tubular columns used in prefabricated and modular construction. In order to achieve high-efficient prefabrication and fast on-site installation, membrane protections using board products and thermal insulation blankets are adopted as the favorable protection method. Three protected tubular columns were tested in a full-scale column furnace with axial load applied. The study variables were different membranes, including fiber reinforced calcium silicate (FRCS) boards, rock wool and aluminum silica (Fiberfrax) insulations. The results suggest that one layer of 12 mm FRCS board with rock wool insulation has insufficient fire protection. However, steel columns protected with two layers of 12 mm FRCS boards with insulation appeared to have good fire resistances and could achieve a fire resistance rating as high as 2.5~3.0 h. PMID:29547574
Fire resistance properties of ceramic wool fiber reinforced intumescent coatings
NASA Astrophysics Data System (ADS)
Amir, N.; Othman, W. M. S. W.; Ahmad, F.
2015-07-01
This research studied the effects of varied weight percentage and length of ceramic wool fiber (CWF) reinforcement to fire retardant performance of epoxy-based intumescent coating. Ten formulations were developed using ammonium polyphosphate (APP), expandable graphite (EG), melamine (MEL) and boric acid (BA). The mixing was conducted in two stages; powdered materials were grinded in Rocklabs mortar grinder and epoxy-mixed using Caframo mixer at low speed mixing. The samples were applied on mild steel substrate and exposed to 500°C heat inside Carbolite electric furnace. The char expansion and its physical properties were observed. Scanning electron microscopy (SEM) analyses were conducted to inspect the fiber dispersion, fiber condition and the cell structure of both coatings and chars produced. Thermogravimetric analyses (TGA) were conducted to study the thermal properties of the coating such as degradation temperature and residual weight. Fire retardant performance was determined by measuring backside temperature of substrate in 1-hour, 1000°C Bunsen burner test according to UL 1709 fire regime. The results showed that intumescent coating reinforced with CWF produced better fire resistance performance. When compared to unreinforced coating, formulation S6-15 significantly reduced steel temperature at approximately 34.7% to around 175°C. However, higher fiber weight percentage had slightly decreased fire retardant performance of the coating.
Fire-Resistant Hydrogel-Fabric Laminates: A Simple Concept That May Save Lives.
Illeperuma, Widusha R K; Rothemund, Philipp; Suo, Zhigang; Vlassak, Joost J
2016-01-27
There is a large demand for fabrics that can survive high-temperature fires for an extended period of time, and protect the skin from burn injuries. Even though fire-resistant polymer fabrics are commercially available, many of these fabrics are expensive, decompose rapidly, and/or become very hot when exposed to high temperatures. We have developed a new class of fire-retarding materials by laminating a hydrogel and a fabric. The hydrogel contains around 90% water, which has a large heat capacity and enthalpy of vaporization. When the laminate is exposed to fire, a large amount of energy is absorbed as water heats up and evaporates. The temperature of the hydrogel cannot exceed 100 °C until it is fully dehydrated. The fabric has a low thermal conductivity and maintains the temperature gradient between the hydrogel and the skin. The laminates are fabricated using a recently developed tough hydrogel to ensure integrity of the laminate during processing and use. A thermal model predicts the performance of the laminates and shows that they have excellent heat resistance in good agreement with experiments, making them viable candidates in life saving applications such as fire-resistant blankets or apparel.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xiong, Yongliang; Wang, Yifeng
Advanced, fire-resistant activated carbon compositions useful in adsorbing gases; and having vastly improved fire resistance are provided, and methods for synthesizing the compositions are also provided. The advanced compositions have high gas adsorption capacities and rapid adsorption kinetics (comparable to commercially-available activated carbon), without having any intrinsic fire hazard. They also have superior performance to Mordenites in both adsorption capacities and kinetics. In addition, the advanced compositions do not pose the fibrous inhalation hazard that exists with use of Mordenites. The fire-resistant compositions combine activated carbon mixed with one or more hydrated and/or carbonate-containing minerals that release H.sub.2O and/or CO.sub.2more » when heated. This effect raises the spontaneous ignition temperature to over 500.degree. C. in most examples, and over 800.degree. C. in some examples. Also provided are methods for removing and/or separating target gases, such as Krypton or Argon, from a gas stream by using such advanced activated carbons.« less
Fire extinguishing tests -80 with methyl alcohol gasoline
NASA Astrophysics Data System (ADS)
Holmstedt, G.; Ryderman, A.; Carlsson, B.; Lennmalm, B.
1980-10-01
Large scale tests and laboratory experiments were carried out for estimating the extinguishing effectiveness of three alcohol resistant aqueous film forming foams (AFFF), two alcohol resistant fluoroprotein foams and two detergent foams in various poolfires: gasoline, isopropyl alcohol, acetone, methyl-ethyl ketone, methyl alcohol and M15 (a gasoline, methyl alcohol, isobutene mixture). The scaling down of large scale tests for developing a reliable laboratory method was especially examined. The tests were performed with semidirect foam application, in pools of 50, 11, 4, 0.6, and 0.25 sq m. Burning time, temperature distribution in the liquid, and thermal radiation were determined. An M15 fire can be extinguished with a detergent foam, but it is impossible to extinguish fires in polar solvents, such as methyl alcohol, acetone, and isopropyl alcohol with detergent foams, AFFF give the best results; and performances with small pools can hardly be correlated with results from large scale fires.
WILDFIRE IGNITION RESISTANCE ESTIMATOR WIZARD SOFTWARE DEVELOPMENT REPORT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Phillips, M.; Robinson, C.; Gupta, N.
2012-10-10
This report describes the development of a software tool, entitled “WildFire Ignition Resistance Estimator Wizard” (WildFIRE Wizard, Version 2.10). This software was developed within the Wildfire Ignition Resistant Home Design (WIRHD) program, sponsored by the U. S. Department of Homeland Security, Science and Technology Directorate, Infrastructure Protection & Disaster Management Division. WildFIRE Wizard is a tool that enables homeowners to take preventive actions that will reduce their home’s vulnerability to wildfire ignition sources (i.e., embers, radiant heat, and direct flame impingement) well in advance of a wildfire event. This report describes the development of the software, its operation, its technicalmore » basis and calculations, and steps taken to verify its performance.« less
Study to develop improved fire resistant aircraft passenger seat materials
NASA Technical Reports Server (NTRS)
Duskin, F. E.; Schutter, K. J.; Sieth, H. H.; Trabold, E. L.
1980-01-01
The Phase 3 study of the NASA 'Improved Fire Resistant Aircraft Seat Materials' involved fire tests of improved materials in multilayered combinations representative of cushion configurations. Tests were conducted to determine their thermal, smoke, and fire resistance characteristics. Additionally, a 'Design Guideline' for Fire Resistant Passenger Seats was written outlining general seat design considerations. Finally, a three-abreast 'Tourist Class' passenger seat assembly fabricated from the most advanced fire-resistant materials was delivered.
Yew, M C; Ramli Sulong, N H; Yew, M K; Amalina, M A; Johan, M R
2014-01-01
This paper aims to synthesize and characterize an effective intumescent fire protective coating that incorporates eggshell powder as a novel biofiller. The performances of thermal stability, char formation, fire propagation, water resistance, and adhesion strength of coatings have been evaluated. A few intumescent flame-retardant coatings based on these three ecofriendly fire retardant additives ammonium polyphosphate phase II, pentaerythritol and melamine mixed together with flame-retardant fillers, and acrylic binder have been prepared and designed for steel. The fire performance of the coatings has conducted employing BS 476: Part 6-Fire propagation test. The foam structures of the intumescent coatings have been observed using field emission scanning electron microscopy. On exposure, the coated specimens' B, C, and D had been certified to be Class 0 due to the fact that their fire propagation indexes were less than 12. Incorporation of ecofriendly eggshell, biofiller into formulation D led to excellent performance in fire stopping (index value, (I) = 4.3) and antioxidation of intumescent coating. The coating is also found to be quite effective in water repellency, uniform foam structure, and adhesion strength.
Yew, M. C.; Ramli Sulong, N. H.; Yew, M. K.; Amalina, M. A.; Johan, M. R.
2014-01-01
This paper aims to synthesize and characterize an effective intumescent fire protective coating that incorporates eggshell powder as a novel biofiller. The performances of thermal stability, char formation, fire propagation, water resistance, and adhesion strength of coatings have been evaluated. A few intumescent flame-retardant coatings based on these three ecofriendly fire retardant additives ammonium polyphosphate phase II, pentaerythritol and melamine mixed together with flame-retardant fillers, and acrylic binder have been prepared and designed for steel. The fire performance of the coatings has conducted employing BS 476: Part 6-Fire propagation test. The foam structures of the intumescent coatings have been observed using field emission scanning electron microscopy. On exposure, the coated specimens' B, C, and D had been certified to be Class 0 due to the fact that their fire propagation indexes were less than 12. Incorporation of ecofriendly eggshell, biofiller into formulation D led to excellent performance in fire stopping (index value, (I) = 4.3) and antioxidation of intumescent coating. The coating is also found to be quite effective in water repellency, uniform foam structure, and adhesion strength. PMID:25136687
Conference on the Development of Fire-Resistant Aircraft Passenger Seats
NASA Technical Reports Server (NTRS)
Fewell, L. L.; Kourtides, D. A.; Rosser, R. W.; Parker, J. A.
1976-01-01
Papers are presented dealing with the development of aircraft seats with the minimum fire risk. Criteria examined include: flame spread, heat release, and smoke and/or toxic fumes. Materials and performance specifications of all seat material options are provided.
Full-scale aircraft cabin flammability tests of improved fire-resistant materials, test series 2
NASA Technical Reports Server (NTRS)
Stuckey, R. N.; Bricker, R. W.; Kuminecz, J. F.; Supkis, D. E.
1976-01-01
Full-scale aircraft flammability tests in which the effectiveness of new fire-resistant materials was evaluated by comparing their burning characteristics with those of other fire-resistant aircraft materials were described. New-fire-resistant materials that are more economical and better suited for aircraft use than the previously tested fire-resistant materials were tested. The fuel ignition source for one test was JP-4; a smokeless fuel was used for the other test. Test objectives, methods, materials, and results are presented and discussed. The results indicate that, similar to the fire-resistant materials tested previously, the new materials decompose rather than ignite and do not support fire propagation. Furthermore, the new materials did not produce a flash fire.
Li, Heng; Wu, Dabei; Wu, Jin; Dong, Li-Ying; Zhu, Ying-Jie; Hu, Xianluo
2017-11-01
Separators play a pivotal role in the electrochemical performance and safety of lithium-ion batteries (LIBs). The commercial microporous polyolefin-based separators often suffer from inferior electrolyte wettability, low thermal stability, and severe safety concerns. Herein, a novel kind of highly flexible and porous separator based on hydroxyapatite nanowires (HAP NWs) with excellent thermal stability, fire resistance, and superior electrolyte wettability is reported. A hierarchical cross-linked network structure forms between HAP NWs and cellulose fibers (CFs) via hybridization, which endows the separator with high flexibility and robust mechanical strength. The high thermal stability of HAP NW networks enables the separator to preserve its structural integrity at temperatures as high as 700 °C, and the fire-resistant property of HAP NWs ensures high safety of the battery. In particular, benefiting from its unique composition and highly porous structure, the as-prepared HAP/CF separator exhibits near zero contact angle with the liquid electrolyte and high electrolyte uptake of 253%, indicating superior electrolyte wettability compared with the commercial polyolefin separator. The as-prepared HAP/CF separator has unique advantages of superior electrolyte wettability, mechanical robustness, high thermal stability, and fire resistance, thus, is promising as a new kind of separator for advanced LIBs with enhanced performance and high safety. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Fire extinguishing tests -80 with methyl alcohol gasoline (in MIXED)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holmstedt, G.; Ryderman, A.; Carlsson, B.
1980-01-01
Large scale tests and laboratory experiments were carried out for estimating the extinguishing effectiveness of three alcohol resistant aqueous film forming foams (AFFF), two alcohol resistant fluoroprotein foams and two detergent foams in various poolfires: gasoline, isopropyl alcohol, acetone, methyl-ethyl ketone, methyl alcohol and M15 (a gasoline, methyl alcohol, isobutene mixture). The scaling down of large scale tests for developing a reliable laboratory method was especially examined. The tests were performed with semidirect foam application, in pools of 50, 11, 4, 0.6, and 0.25 sq m. Burning time, temperature distribution in the liquid, and thermal radiation were determined. An M15more » fire can be extinguished with a detergent foam, but it is impossible to extinguish fires in polar solvents, such as methyl alcohol, acetone, and isopropyl alcohol with detergent foams, AFFF give the best results, and performances with small pools can hardly be correlated with results from large scale fires.« less
NASA Technical Reports Server (NTRS)
Arnold, D. B.; Burnside, J. V.; Hajari, J. V.
1976-01-01
Fire resistance mechanical property tests were conducted on sandwich configurations composed of resin-fiberglass laminates bonded with adhesives to Nomex honeycomb core. The test results were compared to proposed and current requirements for aircraft floor panel applications to demonstrate that the fire safety of the airplane could be improved without sacrificing mechanical performance of the aircraft floor panels.
NASA Astrophysics Data System (ADS)
Zhang, Yuehong; Luan, Weiling; Jiang, Tao
2017-12-01
New intumescent flame retardant (IFR) coatings with different fire retardants were prepared in this paper. Expandable graphite (EG) and Aluminium hydroxide (ATH) were respectively added into the conventional IFR coating system, which included ammonium polyphosphate (APP) / pentaerythritol (PER) / melamine (MEL). The fireproofing time and heat insulating properties of the additives acted as fire retardants were investigated via thermogravimetry analysis (TGA) and fire resistance test of homemade big panel test. The morphology of the char layer structure was achieved by scanning electron microscopy (SEM). The highlight of the paper was that the coating samples were pretreated under Co-60 radiation. The influence of radiation on the fire resistance time and char layer height was investigated. The results showed that the prepared IFR coatings can be used in Co-60 radiation for more than 90 min when encountering fire. It would be a reference for radiation shielding in nuclear environment.
NASA Astrophysics Data System (ADS)
Pucinotti, Raffaele; Ferrario, Fabio; Bursi, Oreste S.
2008-07-01
A multi-objective advanced design methodology dealing with seismic actions followed by fire on steel-concrete composite full strength joints with concrete filled tubes is proposed in this paper. The specimens were designed in detail in order to exhibit a suitable fire behaviour after a severe earthquake. The major aspects of the cyclic behaviour of composite joints are presented and commented upon. The data obtained from monotonic and cyclic experimental tests have been used to calibrate a model of the joint in order to perform seismic simulations on several moment resisting frames. A hysteretic law was used to take into account the seismic degradation of the joints. Finally, fire tests were conducted with the objective to evaluate fire resistance of the connection already damaged by an earthquake. The experimental activity together with FE simulation demonstrated the adequacy of the advanced design methodology.
Behaviour of Reinforced Concrete Columns of Various Cross-Sections Subjected to Fire
NASA Astrophysics Data System (ADS)
Balaji, Aneesha; Muhamed Luquman, K.; Nagarajan, Praveen; Madhavan Pillai, T. M.
2016-09-01
Fire resistance is one of the crucial design regulations which are now mandatory in most of the design codes. Therefore, a thorough knowledge of behaviour of structures exposed to fire is required in this aspect. Columns are the most vulnerable structural member to fire as it can be exposed to fire from all sides. However, the data available for fire resistant design for columns are limited. Hence the present work is focused on the effect of cross-sectional shape of column in fire resistance design. The various cross-sections considered are Square, Ell (L), Tee (T), and Plus (`+') shape. Also the effect of size and shape and distribution of steel reinforcement on fire resistance of columns is studied. As the procedure for determining fire resistance is not mentioned in Indian Standard code IS 456 (2000), the simplified method (500 °C isotherm method) recommended in EN 1992-1-2:2004 (E) (Eurocode 2) is adopted. The temperature profiles for various cross-sections are developed using finite element method and these profiles are used to predict fire resistance capability of compression members. The fire resistance based on both numerical and code based methods are evaluated and compared for various types of cross-section.
29 CFR 1926.155 - Definitions applicable to this subpart.
Code of Federal Regulations, 2014 CFR
2014-07-01
... part, fire resistance shall be determined by the Standard Methods of Fire Tests of Building... knowledgeable, trained, and skilled in the safe evacuation of employees during emergency situations and in assisting in fire fighting operations. (f) Fire resistance means so resistant to fire that, for specified...
29 CFR 1926.155 - Definitions applicable to this subpart.
Code of Federal Regulations, 2012 CFR
2012-07-01
... part, fire resistance shall be determined by the Standard Methods of Fire Tests of Building... knowledgeable, trained, and skilled in the safe evacuation of employees during emergency situations and in assisting in fire fighting operations. (f) Fire resistance means so resistant to fire that, for specified...
29 CFR 1926.155 - Definitions applicable to this subpart.
Code of Federal Regulations, 2011 CFR
2011-07-01
... part, fire resistance shall be determined by the Standard Methods of Fire Tests of Building... knowledgeable, trained, and skilled in the safe evacuation of employees during emergency situations and in assisting in fire fighting operations. (f) Fire resistance means so resistant to fire that, for specified...
29 CFR 1926.155 - Definitions applicable to this subpart.
Code of Federal Regulations, 2013 CFR
2013-07-01
... part, fire resistance shall be determined by the Standard Methods of Fire Tests of Building... knowledgeable, trained, and skilled in the safe evacuation of employees during emergency situations and in assisting in fire fighting operations. (f) Fire resistance means so resistant to fire that, for specified...
29 CFR 1926.155 - Definitions applicable to this subpart.
Code of Federal Regulations, 2010 CFR
2010-07-01
... part, fire resistance shall be determined by the Standard Methods of Fire Tests of Building... knowledgeable, trained, and skilled in the safe evacuation of employees during emergency situations and in assisting in fire fighting operations. (f) Fire resistance means so resistant to fire that, for specified...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-18
..., suppliers, or distributors of fire-resistant fibers, yarns, fabrics, or military uniforms) submitted.... The law does not restrict DoD's selection and use of fabrics containing fire-resistant rayon fiber... from selecting fabrics that include fire- resistant rayon fibers. Response: These responses have...
Forest-fire model with natural fire resistance.
Yoder, Mark R; Turcotte, Donald L; Rundle, John B
2011-04-01
Observations suggest that contemporary wildfire suppression practices in the United States have contributed to conditions that facilitate large, destructive fires. We introduce a forest-fire model with natural fire resistance that supports this theory. Fire resistance is defined with respect to the size and shape of clusters; the model yields power-law frequency-size distributions of model fires that are consistent with field observations in the United States, Canada, and Australia.
Fire Safety Aspects of Polymeric Materials. Volume 6. Aircraft. Civil and Military
1977-01-01
resistance of the existing Polyurethane foam- based seating sys- tems be improved through design, construction, and selection of covering materials. 12. A...aircraft interiors under real fire conditions. To provide the data base for developing improved fire safety standards for aircraft, four types of...the determination of immobilizing effect was based on performance in the swimming test, a simple exercise method also favored by Kimmerle to provide
Charring Rate for Fire Exposed X-Lam
NASA Astrophysics Data System (ADS)
Wong, Bernice VY; Fah Tee, Kong
2017-06-01
Design of timber structures has been outlined in Eurocode 5. Notional charring rate for softwood and hardwood timber is given. For the performance of X-LAM panels in fire, only little information on charring is available and whether the fire behaviour of X-LAM is similar to homogenous timber panels has not yet been systematically analysed. This paper presents an overview of fire performance of X-LAM and evaluation of its resistance to elevated temperature as an element of structure in comparison to homogeneous timber panels. Numerical study has been carried out based on available experimental results. Charring rates for X-LAM panels obtained from experimental results are compared with those obtained from Eurocode 5 and proposed simplified model.
NASA Technical Reports Server (NTRS)
Anderson, R. A.; Ougland, R. M.; Karch, R. J.
1978-01-01
Extensive fire resistance and mechanical property tests were conducted on sandwich configurations composed of resin-fiberglass laminates bonded with adhesive to Nomex honeycomb and foam core. The test results were used to select a combination of materials that would improve the fire safety of the airplane without sacrificing mechanical performance of the aircraft floor panels. A test panel is being service evaluated in a commercial aircraft.
NASA Astrophysics Data System (ADS)
Hilali, Mohamed M.
2005-11-01
A simple cost-effective approach was proposed and successfully employed to fabricate high-quality screen-printed (SP) contacts to high sheet-resistance emitters (100 O/sq) to improve the Si solar cell efficiency. Device modeling was used to quantify the performance enhancement possible from the high sheet-resistance emitter for various cell designs. It was found that for performance enhancement from the high sheet-resistance emitter, certain cell design criteria must be satisfied. Model calculations showed that in order to achieve any performance enhancement over the conventional ˜40 O/sq emitter, the high sheet resistance emitter solar cell must have a reasonably good (<120,000 cm/s) or low front-surface recombination velocity (FSRV). Model calculations were also performed to establish requirements for high fill factors (FFs). The results showed that the series resistance should be less than 0.8 O-cm2, the shunt resistance should be greater than 1000 O-cm2, and the junction leakage current should be less than 25 nA/cm2. Analytical microscopy and surface analysis techniques were used to study the Ag-Si contact interface of different SP Ag pastes. Physical and electrical properties of SP Ag thick-film contacts were studied and correlated to understand and achieve good-quality ohmic contacts to high sheet-resistance emitters for solar cells. This information was then used to define the criteria for high-quality screen-printed contacts. The role of paste constituents and firing scheme on contact quality were investigated to tailor the high-quality screen-printed contact interface structure that results in high performance solar cells. Results indicated that small particle size, high glass transition temperature, rapid firing and less aggressive glass frit help in producing high-quality contacts. Based on these results high-quality SP contacts with high FFs > 0.78 on high sheet-resistance emitters were achieved for the first time using a simple single-step firing process. This technology was applied to different substrates (monocrystalline and multicrystalline) and surfaces (textured and planar). Cell efficiencies of ˜16.2% on low-cost EFG ribbon substrates were achieved on high sheet-resistance emitters with SP contacts. A record high-efficiency SP solar cell of 19% with textured high sheet-resistance emitter was also fabricated and modeled.
NASA Astrophysics Data System (ADS)
Hartley, M. D.; Jaques, R. E.
1986-11-01
The Canadian Electrical Code and the National Building Code in Canada recognize only two designations in regards to fire resistance of cables; cables for use in combustible (residential) buildings and cables for use in non-combustible buildings. The Test standard for cables for non-combustible buildings resembles IEEE-383. However, it is more severe; particularly for small nonarmoured cables such as Inside Wiring Cable. This forthcoming requirement has necessitated material and product development. Although an Inside Wiring cable modification of both insulation and jacket was undertaken, the large volume fraction of combustible material in the jacket vis a vis the insulation made it the area of greatest impact. The paper outlines the development and its effect on cable performance.
Durel, C-E; Denancé, C; Brisset, M-N
2009-02-01
Fire blight, caused by the bacterium Erwinia amylovora, is one of the most destructive diseases of apple (Malus xdomestica) worldwide. No major, qualitative gene for resistance to this disease has been identified so far in apple. A quantitative trait locus (QTL) analysis was performed in two F1 progenies derived from two controled crosses: one between the susceptible rootstock cultivar 'MM106' and the resistant ornamental cultivar 'Evereste' and the other one between the moderately susceptible cultivar 'Golden Delicious' and the wild apple Malus floribunda clone 821, with unknown level of fire blight resistance. Both progenies were inoculated in the greenhouse with the same reference strain of E. amylovora. The length of stem necrosis was scored 7 and 14 days after inoculation. A strong QTL effect was identified in both 'Evereste' and M. floribunda 821 at a similar position on the distal region of linkage group 12 of the apple genome. From 50% to 70% of the phenotypic variation was explained by the QTL in 'Evereste' progeny according to the scored trait. More than 40% of the phenotypic variation was explained by the M. floribunda QTL in the second progeny. It was shown that 'Evereste' and M. floribunda 821 carried distinct QTL alleles at that genomic position. A small additional QTL was identified in 'Evereste' on linkage group 15, which explained about 6% of the phenotypic variation. Although it was not possible to confirm whether or not 'Evereste' and M. floribunda QTL belonged to the same locus or two distinct closely related loci, these QTL can be valuable targets in marker-assisted selection to obtain fire blight resistant apple cultivars and form a starting point for discovering the function of the genes controlling apple fire blight resistance.
Condon, Lea A.; Pyke, David A.
2018-01-01
Shrubs, bunchgrasses and biological soil crusts (biocrusts) are believed to contribute to site resistance to plant invasions in the presence of cattle grazing. Although fire is a concomitant disturbance with grazing, little is known regarding their combined impacts on invasion resistance. We are the first to date to test the idea that biotic communities mediate the effects of disturbance on site resistance. We assessed cover of Bromus tectorum, shrubs, native bunchgrasses, lichens and mosses in 99 burned and unburned plots located on similar soils where fires occurred between 12 and 23 years before sampling. Structural equation modeling was used to test hypothesized relationships between environmental and disturbance characteristics, the biotic community and resistance to B. tectorum cover. Characteristics of fire and grazing did not directly relate to cover of B. tectorum. Relationships were mediated through shrub, bunchgrass and biocrust communities. Increased site resistance following fire was associated with higher bunchgrass cover and recovery of bunchgrasses and mosses with time since fire. Evidence of grazing was more pronounced on burned sites and was positively correlated with the cover of B. tectorum, indicating an interaction between fire and grazing that decreases site resistance. Lichen cover showed a weak, negative relationship with cover of B. tectorum. Fire reduced near-term site resistance to B. tectorum on actively grazed rangelands. Independent of fire, grazing impacts resulted in reduced site resistance to B. tectorum, suggesting that grazing management that enhances plant and biocrust communities will also enhance site resistance.
Fire resistance of structural composite lumber products
Robert H. White
2006-01-01
Use of structural composite lumber products is increasing. In applications requiring a fire resistance rating, calculation procedures are used to obtain the fire resistance rating of exposed structural wood products. A critical factor in the calculation procedures is char rate for ASTM E 119 fire exposure. In this study, we tested 14 structural composite lumber...
van Mantgem, Phillip J.; Schwartz, Mark
2003-01-01
An essential component to models of fire-caused tree mortality is an assessment of cambial damage. Cambial heat resistance has been traditionally measured in large overstory trees with thick bark, although small trees have thinner bark and thus are more sensitive to fire. We undertook this study to determine if current models of bark heat transfer are applicable to small trees (<20 cm diameter at breast height (dbh)). We performed this work in situ on four common species in the mixed conifer forests of the Sierra Nevada, California.The allometric relationship between bole diameter and bark thickness for each species was linear, even for very small trees (5 cm dbh). Heating experiments demonstrated that bark thickness was the primary determinant of cambial heat resistance. We found only slight, but statistically significant, among species differences in bark thermal properties. Our most significant finding was that small trees were more resistant to heating than expected from commonly used models of bark heat transfer. Our results may differ from those of existing models because we found smaller trees to have a greater proportion of inner bark, which appears to have superior insulating properties compared to outer bark. From a management perspective, growth projections suggest that a 50-year fire-free interval may allow some fire intolerant species to achieve at least some degree of cambial heat resistance in the Sierra Nevada.
Fire resistance of wood members with directly applied protection
Robert H. White
2009-01-01
Fire-resistive wood construction is achieved either by having the structural elements be part of fire-rated assemblies or by using elements of sufficient size that the elements themselves have the required fire-resistance ratings. For exposed structural wood elements, the ratings in the United States are calculated using either the T.T. Lie method or the National...
Heat Transfer Principles in Thermal Calculation of Structures in Fire
Zhang, Chao; Usmani, Asif
2016-01-01
Structural fire engineering (SFE) is a relatively new interdisciplinary subject, which requires a comprehensive knowledge of heat transfer, fire dynamics and structural analysis. It is predominantly the community of structural engineers who currently carry out most of the structural fire engineering research and design work. The structural engineering curriculum in universities and colleges do not usually include courses in heat transfer and fire dynamics. In some institutions of higher education, there are graduate courses for fire resistant design which focus on the design approaches in codes. As a result, structural engineers who are responsible for structural fire safety and are competent to do their jobs by following the rules specified in prescriptive codes may find it difficult to move toward performance-based fire safety design which requires a deep understanding of both fire and heat. Fire safety engineers, on the other hand, are usually focused on fire development and smoke control, and may not be familiar with the heat transfer principles used in structural fire analysis, or structural failure analysis. This paper discusses the fundamental heat transfer principles in thermal calculation of structures in fire, which might serve as an educational guide for students, engineers and researchers. Insights on problems which are commonly ignored in performance based fire safety design are also presented. PMID:26783379
Broggini, Giovanni A L; Wöhner, Thomas; Fahrentrapp, Johannes; Kost, Thomas D; Flachowsky, Henryk; Peil, Andreas; Hanke, Maria-Viola; Richter, Klaus; Patocchi, Andrea; Gessler, Cesare
2014-08-01
The fire blight susceptible apple cultivar Malus × domestica Borkh. cv. 'Gala' was transformed with the candidate fire blight resistance gene FB_MR5 originating from the crab apple accession Malus × robusta 5 (Mr5). A total of five different transgenic lines were obtained. All transgenic lines were shown to be stably transformed and originate from different transgenic events. The transgenic lines express the FB_MR5 either driven by the constitutive CaMV 35S promoter and the ocs terminator or by its native promoter and terminator sequences. Phenotyping experiments were performed with Mr5-virulent and Mr5-avirulent strains of Erwinia amylovora, the causal agent of fire blight. Significantly less disease symptoms were detected on transgenic lines after inoculation with two different Mr5-avirulent E. amylovora strains, while significantly more shoot necrosis was observed after inoculation with the Mr5-virulent mutant strain ZYRKD3_1. The results of these experiments demonstrated the ability of a single gene isolated from the native gene pool of apple to protect a susceptible cultivar from fire blight. Furthermore, this gene is confirmed to be the resistance determinant of Mr5 as the transformed lines undergo the same gene-for-gene interaction in the host-pathogen relationship Mr5-E. amylovora. © 2014 Society for Experimental Biology, Association of Applied Biologists and John Wiley & Sons Ltd.
Conference on Fire Resistant Materials: A compilation of presentations and papers
NASA Technical Reports Server (NTRS)
Kourtides, D. A. (Editor); Johnson, G. A. (Editor)
1979-01-01
The proceedings of the NASA IRE Resistant Materials Engineering (FIREMEN) Program held at Boeing Commercial Airplane Company, Seattle, Washington, on March 1-2, 1979 are reported. The conference was to discuss the results of research by the National Aeronautics and Space Administration in the field of aircraft fire safety and fire-resistant materials. The program topics include the following: (1) large-scale testing; (2) fire toxicology; (3) polymeric materials; and (4) fire modeling.
Conference on Fire Resistant Materials (FIREMEN): A compilation of presentations and papers
NASA Technical Reports Server (NTRS)
Kourtides, D. A. (Editor)
1978-01-01
The proceedings of the NASA Fire Resistant Materials Engineering (FIREMEN) Program held at Ames Research Center on April, 13, 14, 1978 are reported. The purpose of the conference was to discuss the results of NASA in the field of aircraft fire safety and fire resistant materials. The program components include the following: (1) large-scale testing; (2) fire toxicology; (3) polymeric materials; and (4) bibliography related and/or generated from the program.
Fire Resistant, Moisture Barrier Membrane
NASA Technical Reports Server (NTRS)
St.Clair, Terry L. (Inventor)
2000-01-01
A waterproof and breathable, fire-resistant laminate is provided for use in tents, garments, shoes, and covers, especially in industrial, military and emergency situations. The laminate permits water vapor evaporation while simultaneously preventing liquid water penetration. Further, the laminate is fire-resistant and significantly reduces the danger of toxic compound production when exposed to flame or other high heat source. The laminate may be applied to a variety of substrates and is comprised of a silicone rubber and plurality of fire-resistant, inherently thermally-stable polyimide particles.
Fire Resistant, Moisture Barrier Membrane
NASA Technical Reports Server (NTRS)
St.Clair, Terry L. (Inventor)
1998-01-01
A waterproof and breathable, fire-resistant laminate is provided for use in tents, garments, shoes, and covers, especially in industrial, military and emergency situations. The laminate permits water vapor evaporation while simultaneously preventing liquid water penetration. Further, the laminate is fire-resistant and significantly reduces the danger of toxic compound production when exposed to flame or other high heat source. The laminate may be applied to a variety of substrates and is comprised of a silicone rubber and plurality of fire-resistant, inherently thermally-stable polyimide particles.
USDA-ARS?s Scientific Manuscript database
Breeding of fire blight resistant scions and rootstocks is a goal of several international apple breeding programs, as options are limited for management of this destructive disease caused by the bacterial pathogen Erwinia amylovora. A broad, large effect QTL for fire blight resistance has been pre...
Full-scale aircraft cabin flammability tests of improved fire-resistant materials
NASA Technical Reports Server (NTRS)
Stuckey, R. N.; Surpkis, D. E.; Price, L. J.
1974-01-01
Full-scale aircraft cabin flammability tests to evaluate the effectiveness of new fire-resistant materials by comparing their burning characteristics with those of older aircraft materials are described. Three tests were conducted and are detailed. Test 1, using pre-1968 materials, was run to correlate the procedures and to compare the results with previous tests by other organizations. Test 2 included newer, improved fire-resistant materials. Test 3 was essentially a duplicate of test 2, but a smokeless fuel was used. Test objectives, methods, materials, and results are presented and discussed. Results indicate that the pre-1968 materials ignited easily, allowed the fire to spread, produced large amounts of smoke and toxic combustion products, and resulted in a flash fire and major fire damage. The newer fire-resistant materials did not allow the fire to spread. Furthermore, they produced less, lower concentrations of toxic combustion products, and lower temperatures. The newer materials did not produce a flash fire.
Fire resistivity and toxicity studies of candidate aircraft passenger seat materials
NASA Technical Reports Server (NTRS)
Fewell, L. L.; Trabold, E. L.; Spieth, H.
1978-01-01
Fire resistivity studies were conducted on a wide range of candidate nonmetallic materials being considered for the construction of improved fire resistant aircraft passenger seats. These materials were evaluated on the basis of FAA airworthiness burn and smoke generation tests, colorfastness, limiting oxygen index, and animal toxicity tests. Physical, mechanical, and aesthetic properties were also assessed. Candidate seat materials that have significantly improved thermal response to various thermal loads corresponding to reasonable fire threats as they relate to in-flight fire situations, are identified.
Fabrics for fire resistant passenger seats in aircraft
NASA Technical Reports Server (NTRS)
Tesoro, G. C.
1978-01-01
The essential elements of the problem and of approaches to improved fire resistance in aircraft seats are reviewed. The performance requirements and availability of materials, delay in the ignition of upholstery fabric by a small source are considered a realistic objective. Results of experimental studies on the thermal response of fabrics and fabric/foam combinations suggest significant conclusions regarding: (1) the ignition behavior of a commercial 90/10 wool/nylon upholstery fabric relative to fabrics made from thermally stable polymers; (2) the role of the foam backing; (3) the behavior of seams. These results, coupled with data from other sources, also confirm the importance of materials' interactions in multicomponent assemblies, and the need for system testing prior to materials' selection. The use of an interlinear or thermal barrier between upholstery fabric and foam is a promising and viable approach to improved fire resistance of the seat assembly, but experimental evaluation of specific combinations of materials or systems is an essential part of the selection process.
NASA Technical Reports Server (NTRS)
Jayarajan, A.; Johnson, G. A.; Korver, G. L.; Anderson, R. A.
1983-01-01
Five chemically different resin systems with improved fire resistance properties were studied for a possible screenprinting ink application. Fire resistance is hereby defined as the cured ink possessing improvements in flammability, smoke emission, and thermal stability. The developed ink is for application to polyvinyl fluoride film. Only clear inks without pigments were considered. Five formulations were evaluated compared with KC4900 clear acrylic ink, which was used as a baseline. The tests used in the screening evaluation included viscosity, smoke and toxic gas emission, limiting oxygen index (LOI), and polyvinyl fluoride film (PVF) printability. A chlorofluorocarbon resin (FPC461) was selected for optimization studies. The parameters for optimization included screenprinting process performance, quality of coating, and flammability of screenprinted 0.051-mm (0.002-in.) white Tedlar. The quality of the screenprinted coating on Tedlar is dependent on viscosity, curing time, adhesion to polyvinyl fluoride film, drying time (both inscreen and as an applied film), and silk screen mesh material and porosity.
Nano-silica as the go material on heat resistant tunnel lining
NASA Astrophysics Data System (ADS)
Omar, Faizah; Osman, S. A.; Mutalib, A.
2018-04-01
This paper is concerned with passive fire protection method of protective concrete mix that is made up of fly ash, polypropylene fibre, and nano-silica. Nano-silica is focused on as the innovative material to be used in the composition of the protective concrete mix. The previous experimental studies which analyse the performance of passive fire protection on tunnels are discussed. This paper also discusses passive fire protection. The fire protection materials and behaviour analyses of tunnel structure are also presented. At the end of the paper, the recommendation of the optimum composition concrete material with fly ash, polypropylene fibre and nano-silica as tunnel lining fire protective materials is proposed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xiong, Yongliang; Wang, Yifeng
A method of removing a target gas from a gas stream is disclosed. The method uses advanced, fire-resistant activated carbon compositions having vastly improved fire resistance. Methods for synthesizing the compositions are also provided. The advanced compositions have high gas adsorption capacities and rapid adsorption kinetics (comparable to commercially-available activated carbon), without having any intrinsic fire hazard.
Behaviour of Passive Fire Protection K-Geopolymer under Successive Severe Fire Incidents.
Sakkas, Konstantinos; Sofianos, Alexandros; Nomikos, Pavlos; Panias, Dimitrios
2015-09-11
The performance of a fire resistant coating for tunnel passive fire protection under successive severe thermal loading is presented. The material falls under the class of potassium based geopolymers (K-geopolymer) and was prepared by mixing ferronickel (FeNi) slag, doped with pure alumina, with a highly alkaline potassium hydroxide aqueous phase. Its performance was assessed by subjecting a concrete slab with a five cm thick K-geopolymer coating layer into successive RijksWaterStaat (RWS) fire incidents. During the first test, the maximum measured temperature in the K-geopolymer/concrete interface was 250 °C, which is 130 °C lower than the RWS test requirement, while, during the second fire test, the maximum temperature was almost 370 °C, which is still lower than the RWS requirement proving the effectiveness of the material as a thermal barrier. In addition, the material retained its structural integrity, during and after the two tests, without showing any mechanical or thermal damages.
Behaviour of Passive Fire Protection K-Geopolymer under Successive Severe Fire Incidents
Sakkas, Konstantinos; Sofianos, Alexandros; Nomikos, Pavlos; Panias, Dimitrios
2015-01-01
The performance of a fire resistant coating for tunnel passive fire protection under successive severe thermal loading is presented. The material falls under the class of potassium based geopolymers (K-geopolymer) and was prepared by mixing ferronickel (FeNi) slag, doped with pure alumina, with a highly alkaline potassium hydroxide aqueous phase. Its performance was assessed by subjecting a concrete slab with a five cm thick K-geopolymer coating layer into successive RijksWaterStaat (RWS) fire incidents. During the first test, the maximum measured temperature in the K-geopolymer/concrete interface was 250 °C, which is 130 °C lower than the RWS test requirement, while, during the second fire test, the maximum temperature was almost 370 °C, which is still lower than the RWS requirement proving the effectiveness of the material as a thermal barrier. In addition, the material retained its structural integrity, during and after the two tests, without showing any mechanical or thermal damages. PMID:28793554
30 CFR 77.1913 - Fire-resistant wood.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Fire-resistant wood. 77.1913 Section 77.1913 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH... Shaft Sinking § 77.1913 Fire-resistant wood. Except for crossties, timbers, and other wood products...
30 CFR 77.1913 - Fire-resistant wood.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Fire-resistant wood. 77.1913 Section 77.1913 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH... Shaft Sinking § 77.1913 Fire-resistant wood. Except for crossties, timbers, and other wood products...
30 CFR 77.1913 - Fire-resistant wood.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Fire-resistant wood. 77.1913 Section 77.1913 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH... Shaft Sinking § 77.1913 Fire-resistant wood. Except for crossties, timbers, and other wood products...
46 CFR 72.05-55 - Furniture and furnishings.
Code of Federal Regulations, 2010 CFR
2010-10-01
... shall be of approved fire resistant fabrics. (4) All rugs and carpets shall be of wool or other material... subpart, rooms containing “fire resistant furnishings” will be considered to be those in which: (1) All... fire resistant furnishings. In addition, all upholstery and padding of chairs, sofas, etc., in these...
30 CFR 77.1913 - Fire-resistant wood.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Fire-resistant wood. 77.1913 Section 77.1913 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH... Shaft Sinking § 77.1913 Fire-resistant wood. Except for crossties, timbers, and other wood products...
30 CFR 77.1913 - Fire-resistant wood.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fire-resistant wood. 77.1913 Section 77.1913 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH... Shaft Sinking § 77.1913 Fire-resistant wood. Except for crossties, timbers, and other wood products...
Study of skin model and geometry effects on thermal performance of thermal protective fabrics
NASA Astrophysics Data System (ADS)
Zhu, Fanglong; Ma, Suqin; Zhang, Weiyuan
2008-05-01
Thermal protective clothing has steadily improved over the years as new materials and improved designs have reached the market. A significant method that has brought these improvements to the fire service is the NFPA 1971 standard on structural fire fighters’ protective clothing. However, this testing often neglects the effects of cylindrical geometry on heat transmission in flame resistant fabrics. This paper deals with methods to develop cylindrical geometry testing apparatus incorporating novel skin bioheat transfer model to test flame resistant fabrics used in firefighting. Results show that fabrics which shrink during the test can have reduced thermal protective performance compared with the qualities measured with a planar geometry tester. Results of temperature differences between skin simulant sensors of planar and cylindrical tester are also compared. This test method provides a new technique to accurately and precisely characterize the thermal performance of thermal protective fabrics.
Resistance to invasion and resilience to fire in desert shrublands of North America
Brooks, Matthew L.; Chambers, Jeanne C.
2011-01-01
Settlement by Anglo-Americans in the desert shrublands of North America resulted in the introduction and subsequent invasion of multiple nonnative grass species. These invasions have altered presettlement fire regimes, resulted in conversion of native perennial shrublands to nonnative annual grasslands, and placed many native desert species at risk. Effective management of these ecosystems requires an understanding of their ecological resistance to invasion and resilience to fire. Resistance and resilience differ among the cold and hot desert shrublands of the Great Basin, Mojave, Sonoran, and Chihuahuan deserts in North America. These differences are largely determined by spatial and temporal patterns of productivity but also are affected by ecological memory, severity and frequency of disturbance, and feedbacks among invasive species and disturbance regimes. Strategies for preventing or managing invasive plant/fire regimes cycles in desert shrublands include: 1) conducting periodic resource assessments to evaluate the probability of establishment of an altered fire regime; 2) developing an understanding of ecological thresholds associate within invasion resistance and fire resilience that characterize transitions from desirable to undesirable fire regimes; and 3) prioritizing management activities based on resistance of areas to invasion and resilience to fire.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 3 2011-10-01 2011-10-01 false Specification 21PF fire and shock resistant, phenolic-foam insulated, metal overpack. 178.358 Section 178.358 Transportation Other Regulations Relating...) Materials § 178.358 Specification 21PF fire and shock resistant, phenolic-foam insulated, metal overpack. ...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 2 2010-10-01 2010-10-01 false Specification 21PF fire and shock resistant, phenolic-foam insulated, metal overpack. 178.358 Section 178.358 Transportation Other Regulations Relating... Class 7 (Radioactive) Materials § 178.358 Specification 21PF fire and shock resistant, phenolic-foam...
NASA Astrophysics Data System (ADS)
Bahrani, Babak
The objective of this study was to investigate the effects of weathering on the performance of intumescent fire-retardant coatings on wooden products. The weathering effects included primary (solar irradiation, moisture, and temperature) and secondary (environmental contaminants) parameters at various time intervals. Wildland urban interface (WUI) fires have been an increasing threat to lives and properties. Existing solutions to mitigate the damages caused by WUI fires include protecting the structures from ignition and minimizing the fire spread from one structure to another. These solutions can be divided into two general categories: active fire protection systems and passive fire protection systems. Passive systems are either using pre-applied wetting agents (water, gel, or foam) or adding an extra layer (composite wraps or coatings). Fire-retardant coating treatment methods can be divided into impregnated (penetrant) and intumescent categories. Intumescent coatings are easy to apply, economical, and have a better appearance in comparison to other passive fire protection methods, and are the main focus of this study. There have been limited studies conducted on the application of intumescent coatings on wooden structures and their performance after long-term weathering exposure. The main concerns of weathering effects are: 1) the reduction of ignition resistance of the coating layer after weathering; and 2) the fire properties of coatings after weathering since coatings might contribute as a combustible fuel and assist the fire growth after ignition. Three intumescent coatings were selected and exposed to natural weathering conditions in three different time intervals. Two types of tests were performed on the specimens: a combustibility test consisted of a bench-scale performance evaluation using a Cone Calorimeter, and a thermal decomposition test using Simultaneous Differential Scanning Calorimetry (DSC) and Thermogravimetric Analysis (TGA) method (also known as SDT). For each coating type and weathering period, three different radiative heat flux levels were used in the combustibility tests. Data obtained from the tests, including flammability and thermal properties, were gathered, analyzed, and compared to non-weathered specimens. The results revealed visible effects of weathering on pre (and up to)-ignition flammability and intumescent properties, especially decreases in Time-to-Ignition (TTI), Time-to-Intumescence (tintu.), and (maximum) Intumescence Height (Hintu.) values in weathered specimens. These results showed that the ignition resistance of the coating layers decreased after weathering exposure. On the other hand, the obtained results from weathered specimens for the post-ignition flammability properties, especially Peak Heat Release Rate (PHRR) and Effective Heat of Combustion (EHC) did not show a significant difference in comparison to the non-weathered samples. These results demonstrated that the weathered coating layer would not likely to act as an additional combustible fuel to increase fire spread.
Validation and Verification (V and V) Testing on Midscale Flame Resistant (FR) Test Method
2016-12-16
Method for Evaluation of Flame Resistant Clothing for Protection against Fire Simulations Using an Instrumented Manikin. Validation and...complement (not replace) the capabilities of the ASTM F1930 Standard Test Method for Evaluation of Flame Resistant Clothing for Protection against Fire ...Engineering Center (NSRDEC) to complement the ASTM F1930 Standard Test Method for Evaluation of Flame Resistant Clothing for Protection against Fire
Effect of Spacecraft Environmental Variables on the Flammability of Fire Resistant Fabrics
NASA Astrophysics Data System (ADS)
Osorio, A. F.; Fernandez-Pello, C.; Takahashi, S.; Rodriguez, J.; Urban, D. L.; Ruff, G.
2012-01-01
Fire resistant fabrics are used for firefighter, racecar drivers as well as astronaut suits. However, their fire resistant characteristics depend on the environment conditions and require study. Particularly important is the response of these fabrics to elevated oxygen concentration environments and radiant heat from a source such as an adjacent fire. In this work, experiments using two fire resistant fabrics were conducted to study the effect of oxygen concentration, external radiant flux and oxidizer flow velocity in concurrent flame spread. Results show that for a given fabric the minimum oxygen concentration for flame spread depends strongly on the magnitude of the external radiant flux. At increased oxygen concentrations the external radiant flux required for flame spread decreases. Oxidizer flow velocity influences the external radiant flux only when the convective heat flux from the flame has similar values to the external radiant flux. The results of this work provide further understanding of the flammability characteristics of fire resistant fabrics in environments similar to those of future spacecrafts.
Fire-Resistant Materials: Research Overview
DOT National Transportation Integrated Search
1996-12-01
This report provides an overview of the research being conducted by the Federal Aviation Administration (FAA) to develop fire safe cabin materials for commercial aircraft. The objective of the Fire-Resistant Materials program is to eliminate burning ...
Fire resistant polyamide based on 1-(diorganooxyphosphonyl)methyl-2,4- and -2,6diamino benzene
NASA Technical Reports Server (NTRS)
Mikroyannidis, J. A. (Inventor); Kourtides, D. A. (Inventor)
1986-01-01
1-(Diorganooxyphosphonyl)methyl2,4- and-2,6diamino benzenes are reacted with polyacylhalides and optionally comonomers to produce polyamides which have desirable heat and fire resistance properties. These polymers are used to form fibers and fabrics where fire resistance properties are important, e.g., aircraft equipment and structures.
Fire resistance of exposed wood members
Robert H. White
2004-01-01
Fire resistance data on exposed wood beams and columns are plentiful, but few studies have been done on exposed wood members in tension and in decks. To provide data to verify the application of a new calculation procedure, a limited series of fire resistance tests were conducted on wood members loaded in tension and on exposed wood decks.
Highly Flexible Superhydrophobic and Fire-Resistant Layered Inorganic Paper.
Chen, Fei-Fei; Zhu, Ying-Jie; Xiong, Zhi-Chao; Sun, Tuan-Wei; Shen, Yue-Qin
2016-12-21
Traditional paper made from plant cellulose fibers is easily destroyed by either liquid or fire. In addition, the paper making industry consumes a large amount of natural trees and thus causes serious environmental problems including excessive deforestation and pollution. In consideration of the intrinsic flammability of organics and minimizing the effects on the environment and creatures, biocompatible ultralong hydroxyapatite nanowires are an ideal building material for inorganic fire-resistant paper. Herein, a new kind of free-standing, highly flexible, superhydrophobic, and fire-resistant layered inorganic paper has been successfully prepared using ultralong hydroxyapatite nanowires as building blocks after the surface modification with sodium oleate. During the vacuum filtration, ultralong hydroxyapatite nanowires assemble into self-roughened setalike microfibers, avoiding the tedious fabrication process to construct the hierarchical structure; the self-roughened microfibers further form the inorganic paper with a nacrelike layered structure. We have demonstrated that the layered structure can significantly improve the resistance to mechanical destruction of the as-prepared superhydrophobic paper. The as-prepared superhydrophobic and fire-resistant inorganic paper shows excellent nonflammability, liquid repellency to various commercial drinks, high thermal stability, and self-cleaning property. Moreover, we have explored the potential applications of the superhydrophobic and fire-resistant inorganic paper as a highly effective adsorbent for oil/water separation, fire-shielding protector, and writing paper.
Analytical modeling of fire growth on fire-resistive wood-based materials with changing conditions
Mark A. Dietenberger
2006-01-01
Our analytical model of fire growth for the ASTM E 84 tunnel, which simultaneously predicts heat release rate, flame-over area, and pyrolysis area as functions of time for constant conditions, was documented in the 2001 BCC Symposium for different treated wood materials. The model was extended to predict ignition and fire growth on exterior fire-resistive structures...
Flash-Fire Propensity and Heat-Release Rate Studies of Improved Fire Resistant Materials
NASA Technical Reports Server (NTRS)
Fewell, L. L.
1978-01-01
Twenty-six improved fire resistant materials were tested for flash-fire propensity and heat release rate properties. The tests were conducted to obtain a descriptive index based on the production of ignitable gases during the thermal degradation process and on the response of the materials under a specific heat load.
NASA Astrophysics Data System (ADS)
Maślak, Mariusz; Pazdanowski, Michał; Woźniczka, Piotr
2018-01-01
Validation of fire resistance for the same steel frame bearing structure is performed here using three different numerical models, i.e. a bar one prepared in the SAFIR environment, and two 3D models developed within the framework of Autodesk Simulation Mechanical (ASM) and an alternative one developed in the environment of the Abaqus code. The results of the computer simulations performed are compared with the experimental results obtained previously, in a laboratory fire test, on a structure having the same characteristics and subjected to the same heating regimen. Comparison of the experimental and numerically determined displacement evolution paths for selected nodes of the considered frame during the simulated fire exposure constitutes the basic criterion applied to evaluate the validity of the numerical results obtained. The experimental and numerically determined estimates of critical temperature specific to the considered frame and related to the limit state of bearing capacity in fire have been verified as well.
Fibre reinforced concrete exposed to elevated temperature
NASA Astrophysics Data System (ADS)
Novák, J.; Kohoutková, A.
2017-09-01
Although concrete when subject to fire performs very well, its behaviour and properties change dramatically under high temperature due to damaged microstructure and mesostructure. As fibre reinforced concrete (FRC) represents a complex material composed of various components with different response to high temperature, to determine its behaviour and mechanical properties in fire is a demanding task. The presented paper provides a summary of findings on the fire response of fibre FRC. Namely, the information on steel fibre reinforced concrete (SFRC), synthetic fibre reinforced concrete and hybrid (steel + synthetic) fibre reinforced concrete have been gathered from various contributions published up to date. The mechanical properties including the melting point and ignition point of fibres affect significantly the properties of concrete composites with addition of fibres. The combination of steel and synthetic fibres represents a promising alternative how to ensure good toughness of a concrete composite before heating and improve its residual mechanical behaviour and spalling resistance as well as the ductility after heating. While synthetic fibres increase concrete spalling resistance, steel fibres in a concrete mix leads to an improvement in both mechanical properties and resistance to heating effects.
Improved fire-resistant coatings
NASA Technical Reports Server (NTRS)
Hutt, J. B.; Stuart, J. W.
1971-01-01
Water-base coatings containing potassium silicate show improvement in areas of quick air-drying, crack, craze, and abrasion resistance, adherence, and leach resistance. Coatings are useful as thermal-barrier layers in furnaces, and as general purpose fire resistant surfaces where vapor impermeability is not a requirement.
46 CFR 199.175 - Survival craft and rescue boat equipment.
Code of Federal Regulations, 2010 CFR
2010-10-01
... breakage-resistant material. (9) Fire extinguisher. The fire extinguisher must be approved under approval series 162.028. The fire extinguisher must be type B-C, size II, or larger. Two type B-C, size I fire... portions of the hull. (4) Bucket. The bucket must be made of corrosion-resistant material and should either...
The effect of fire retardants on the fire response characteristics of cellulosic materials
NASA Technical Reports Server (NTRS)
Hilado, C. J.; Brauer, D. P.
1978-01-01
The resistance to ignition of fire retardant-treated wood, cotton, and cellulose insulation was studied. The proprietary composition used to treat wood was found to increase resistance to ignition and to reduce smoke toxicity. Cotton treated with boric acid (added by padding on or by vapor phase process) was found to have increased resistance to ignition and decreased smoke toxicity. Boric acid increased the resistance of cellulose insulation to ignition but also slightly increased the smoke toxicity.
Electrical Resistivity Tomography for coal fire mapping over Jharia coal field, India
NASA Astrophysics Data System (ADS)
Pal, S. K.; Kumar, S.; Bharti, A. K.; Pathak, V. K.; Kumar, R.
2016-12-01
Over the decades, coal fires are serious global concern posing grievous hazards to the valuable energy resources, local environments and human life. The coal seam and coal mine fires may be initiated due to improper mining activities, exothermic reactions, lighting, forest fire and other anthropic activities, which burn the coal and may continue underground for decades. The burning of concealed coal seams is a complex process involving numerous ill-defined parameters. Generally, the coal exhibits resistivity of 100 to 500Ωm at normal temperature conditions. During the pyrolysis process, at temperatures greater than 6500C coal became a good conductor with a resistivity of approximately 1 Ωm. The present study deals with the mapping of coal fire over Jharia coal field, India using Electrical Resistivity Tomography (ERT). A state-of-the-art 61-channel 64 electrode FlashRES-Universal ERT data acquisition system has been used for data acquisition in the field. The ERT data have been collected using Gradient array and processed in FlashRES Universal survey data checking program for removing noisy data. Then, filtered output data have been inverted using a 2.5D resistivity inversion program. Low resistivity anomalies over 80m-125m and 320m-390m along the profile are inferred to be active coal fire in seam- XVI at a depth of 25m -35m(Figure 1). High resistivity anomaly over 445m - 510m at a depth of 25m -35m has been delineated, due to void associated with complete combustion of seam- XVI coal, followed by char and ash formation resulting from the coal seam fire. Results prove the efficacy of the ERT study comprising Gradient array for coal fire mapping over, Jharia coal field, India.
Resistance is not futile: The response of hardwoods to fire-caused wounding
Elaine Kennedy Sutherland; Kevin Smith
2000-01-01
Fires wound trees; but not all of them, and not always. Specific fire behavior and differences among tree species and individual trees produce variable patterns of wounding and wound response. Our work focuses on the relationships between fire behavior and tree biology to better understand how hardwood trees resist injury to the lower stem and either survive or succumb...
NASA Astrophysics Data System (ADS)
Azieyanti, N. A.; Hakim, Alif; Hasini, Hasril
2017-10-01
A composite mixture of gypsum and natural fibers has been considered in this study to enhance the fire resistance rating of a fire door. Previously the materials used to make a fire door are gypsum and fiber wool where it acts as a protective coating. Normally this fire door must be compact and able to close on its own. Natural fibers have the ability to replace glass fiber cotton because of its features that are available in fiber glass wool. When using fiberglass, it can cause health problem once it is swallowed and inhaled, and may remain in the lungs indefinitely. It also can contribute to lungs cancer. Kapok fiber has been used in this experiment as natural fibers. The objective of the experiment is to analyze the fire resistant rating of the composite mixture of gypsum with kapok fiber. The scopes of the experiment consist of a preparation of composite mixture samples of gypsum with kapok fiber with different composition and thickness, and the fabrication of a fire resistant testing furnace. A testing of samples which were conducted in accordance with the standard MS 1073: PART 2:1996.
Development of the First Cisgenic Apple with Increased Resistance to Fire Blight
Kost, Thomas D.; Gessler, Cesare; Jänsch, Melanie; Flachowsky, Henryk; Patocchi, Andrea; Broggini, Giovanni A. L.
2015-01-01
The generation and selection of novel fire blight resistant apple genotypes would greatly improve the management of this devastating disease, caused by Erwinia amylovora. Such resistant genotypes are currently developed by conventional breeding, but novel breeding technologies including cisgenesis could be an alternative approach. A cisgenic apple line C44.4.146 was regenerated using the cisgene FB_MR5 from wild apple Malus ×robusta 5 (Mr5), and the previously established method involving A. tumefaciens-mediated transformation of the fire blight susceptible cultivar ‘Gala Galaxy’ using the binary vector p9-Dao-FLPi. The line C44.4.146 was shown to carry only the cisgene FB_MR5, controlled by its native regulatory sequences and no transgenes were detected by PCR or Southern blot following heat induced recombinase-mediated elimination of the selectable markers. Although this line contains up to 452 bp of vector sequences, it still matches the original definition of cisgenesis. A single insertion of T-DNA into the genome of 'Gala Galaxy' in chromosome 16 was identified. Transcription of FB_MR5 in line C44.4.146 was similar to the transcription in classically bred descendants of Mr5. Three independent shoot inoculation experiments with a Mr5 avirulent strain of Erwinia amylovora were performed using scissors or syringe. Significantly lower disease symptoms were detected on shoots of the cisgenic line compared to those of untransformed 'Gala Galaxy'. Despite the fact that the pathogen can overcome this resistance by a single nucleotide mutation, this is, to our knowledge, the first prototype of a cisgenic apple with increased resistance to fire blight. PMID:26624292
NASA Astrophysics Data System (ADS)
Liu, Yong Jun; Li, Chao; Zhou, When Jun
2018-06-01
This paper presents some numerical simulation results of tensile properties of reinforcing bars spliced by grout-filled coupling sleeves under fire conditions to identify the effect of load ratio on fire resistance time of spliced reinforcing bars, which provide a useful base for predicting structural behaviors of pre-cast reinforced concrete buildings in fires. A spliced rebar system investigated in this paper consists of two equal-diameter steel reinforcing bars with 25mm diameter and a straight coupling sleeve with 50mm outer and 45mm inner diameters. As a result, the thickness of grout between steel bars and sleeves are 20mm. Firstly, the temperature distributions in steel bars connected by grout- filled coupling sleeves exposed to ISO 834 standard fire were calculated utilizing finite element analysis software ANSYS. Secondly, the stress changes in heated steel bars connected by grout-filled coupling sleeves under different constant tensile loads were calculated step by step until the rebar system failed due to fire. Thus, the fire resistant time of rebar spliced by grout-filled coupling sleeves under different axial tensile loads can be determined, further, the relationship between fire resistance time and axial tensile loads ratio can could be obtained. Finally, the fire resistant times versus axial tensile load ratios curve of grout-filled splice sleeve rebars exposed to ISO 834 standard fire is presented.
NASA Astrophysics Data System (ADS)
Kado, B.; Mohammad, S.; Lee, Y. H.; Shek, P. N.; Kadir, M. A. A.
2018-04-01
Standard fire test was carried out on 3 hollow steel tube and 6 foamed concrete filled steel tube columns. Temperature distribution on the columns was investigated. 1500 kg/m3 and 1800 kg/m3 foamed concrete density at 15%, 20% and 25% load level are the parameters considered. The columns investigated were 2400 mm long, 139.7 mm outer diameter and 6 mm steel tube thickness. The result shows that foamed concrete filled steel tube columns has the highest fire resistance of 43 minutes at 15% load level and low critical temperature of 671 ºC at 25% load level using 1500 kg/m3 foamed concrete density. Fire resistance of foamed concrete filled column increases with lower foamed concrete strength. Foamed concrete can be used to provide more fire resistance to hollow steel column or to replace normal weight concrete in concrete filled columns. Since filling hollow steel with foamed concrete produce column with high fire resistance than unfilled hollow steel column. Therefore normal weight concrete can be substituted with foamed concrete in concrete filled column, it will reduces the self-weight of the structure because of its light weight at the same time providing the desired fire resistance.
Dunivin, Taylor K; Miller, Justine; Shade, Ashley
2018-01-01
Arsenic (As), a toxic element, has impacted life since early Earth. Thus, microorganisms have evolved many As resistance and tolerance mechanisms to improve their survival outcomes given As exposure. We isolated As resistant bacteria from Centralia, PA, the site of an underground coal seam fire that has been burning since 1962. From a 57.4°C soil collected from a vent above the fire, we isolated 25 unique aerobic As resistant bacterial strains spanning seven genera. We examined their diversity, resistance gene content, transformation abilities, inhibitory concentrations, and growth phenotypes. Although As concentrations were low at the time of soil collection (2.58 ppm), isolates had high minimum inhibitory concentrations (MICs) of arsenate and arsenite (>300 mM and 20 mM respectively), and most isolates were capable of arsenate reduction. We screened isolates (PCR and sequencing) using 12 published primer sets for six As resistance genes (AsRGs). Genes encoding arsenate reductase (arsC) and arsenite efflux pumps (arsB, ACR3(2)) were present, and phylogenetic incongruence between 16S rRNA genes and AsRGs provided evidence for horizontal gene transfer. A detailed investigation of differences in isolate growth phenotypes across As concentrations (lag time to exponential growth, maximum growth rate, and maximum OD590) showed a relationship with taxonomy, providing information that could help to predict an isolate's performance given As exposure in situ. Our results suggest that microbiological management and remediation of environmental As could be informed by taxonomically-linked As tolerance, potential for resistance gene transferability, and the rare biosphere.
NASA Astrophysics Data System (ADS)
Chatha, Sukhpal Singh; Sidhu, Hazoor S.; Sidhu, Buta S.
2013-06-01
Ni-20Cr coating was deposited on T91 boiler tube steel by high-velocity oxy-fuel (HVOF) process to enhance high-temperature oxidation resistance. High-temperature performance of bare, as well as HVOF-coated steel specimens was evaluated for 1500 h under in the platen superheater zone of coal-fired boiler, where the temperature was around 900 °C. Experiments were carried out for 15 cycles, each of 100-h duration followed by 1-h cooling at ambient temperature. The extent of degradation of the specimens was assessed by the thickness loss and depth of internal corrosion attack. Ni-20Cr-coated steel performed better than the uncoated steel in actual boiler environment. The improved degradation resistance of Ni-20Cr coating can be attributed to the presence of Cr2O3 in the top oxide scale and dense microstructure.
NASA Astrophysics Data System (ADS)
Ahmad, Samir Mahmmod; Leong, Cheow Siu; Sopian, K.; Zaidi, Saleem H.
2018-03-01
Formation of an Ohmic contact requires a suitable firing temperature, appropriate doping profile, and contact dimensions within resolution limits of the screen-printing process. In this study, the role of the peak firing temperature in standard rapid thermal annealing (RTA) six-zone conveyor belt furnace (CBF) and two inexpensive alternate RTA systems [a custom-designed, three-zone, 5″-diameter quartz tube furnace (QTF) and a tabletop, 3″-diameter rapid thermal processing (RTP)] has been investigated. In addition, the role of sheet resistance and contact area in achieving low-resistance ohmic contacts has been examined. Electrical measurements of ohmic contacts between silver paste/ n +-emitter layer with varying sheet resistances and aluminum paste/ p-doped wafer were carried out in transmission line method configuration. Experimental measurements of the contact resistivity ( ρ c) exhibited the lowest values for CBF at 0.14 mΩ cm2 for Ag and 100 mΩ cm2 for Al at a peak firing temperature of 870°C. For the QTF configuration, lowest measured contact resistivities were 3.1 mΩ cm2 for Ag and 74.1 mΩ cm2 for Al at a peak firing temperature of 925°C. Finally, for the RTP configuration, lowest measured contact resistivities were 1.2 mΩ cm2 for Ag and 68.5 mΩ cm2 for Al at a peak firing temperature of 780°C. The measured contact resistivity exhibits strong linear dependence on sheet resistance. The contact resistivity for Ag decreases with contact area, while for Al the opposite behavior is observed.
Study to develop improved fire resistant aircraft passenger seat materials, phase 2
NASA Technical Reports Server (NTRS)
Duskin, F. E.; Shook, W. H.; Trabold, E. L.; Spieth, H. H.
1978-01-01
Fire tests are reported of improved materials in multilayered combinations representative of cushion configurations. Tests were conducted to determine their thermal, smoke, and fire resistance characteristics. Additionally, a source fire consisting of one and one-half pounds of newspaper in a tented configuration was developed. Finally, a preliminary seat specification was written based upon materials data and general seat design criteria.
Thermal Response of UHMWPE Materials in a Flash Flame Test Environment
2014-11-13
Evaluation of Flame Resistant Clothing for Protection Against Fire Simulations Using an Instrumented Manikin. Several UHMWPE fabrics were tested underneath...PROTECTIVE CLOTHING COTTON FLASH FLAMES UNDERGARMENTS TEST AND EVALUATION FABRICS FLAME TESTING FIRE ...PROTECTION FIRE RESISTANT TEXTILES UHMWPE(ULTRA HIGH MOLECULAR WEIGHT POLYETHYLENE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Amir, N., E-mail: norlailiamir@petronas.com.my; Othman, W. M. S. W., E-mail: wamosa@gmail.com; Ahmad, F., E-mail: faizahmad@petronas.com.my
This research studied the effects of varied weight percentage and length of ceramic wool fiber (CWF) reinforcement to fire retardant performance of epoxy-based intumescent coating. Ten formulations were developed using ammonium polyphosphate (APP), expandable graphite (EG), melamine (MEL) and boric acid (BA). The mixing was conducted in two stages; powdered materials were grinded in Rocklabs mortar grinder and epoxy-mixed using Caframo mixer at low speed mixing. The samples were applied on mild steel substrate and exposed to 500°C heat inside Carbolite electric furnace. The char expansion and its physical properties were observed. Scanning electron microscopy (SEM) analyses were conducted tomore » inspect the fiber dispersion, fiber condition and the cell structure of both coatings and chars produced. Thermogravimetric analyses (TGA) were conducted to study the thermal properties of the coating such as degradation temperature and residual weight. Fire retardant performance was determined by measuring backside temperature of substrate in 1-hour, 1000°C Bunsen burner test according to UL 1709 fire regime. The results showed that intumescent coating reinforced with CWF produced better fire resistance performance. When compared to unreinforced coating, formulation S6-15 significantly reduced steel temperature at approximately 34.7% to around 175°C. However, higher fiber weight percentage had slightly decreased fire retardant performance of the coating.« less
Fire intensity impacts on post-fire temperate coniferous forest net primary productivity
NASA Astrophysics Data System (ADS)
Sparks, Aaron M.; Kolden, Crystal A.; Smith, Alistair M. S.; Boschetti, Luigi; Johnson, Daniel M.; Cochrane, Mark A.
2018-02-01
Fire is a dynamic ecological process in forests and impacts the carbon (C) cycle through direct combustion emissions, tree mortality, and by impairing the ability of surviving trees to sequester carbon. While studies on young trees have demonstrated that fire intensity is a determinant of post-fire net primary productivity, wildland fires on landscape to regional scales have largely been assumed to either cause tree mortality, or conversely, cause no physiological impact, ignoring the impacted but surviving trees. Our objective was to understand how fire intensity affects post-fire net primary productivity in conifer-dominated forested ecosystems on the spatial scale of large wildland fires. We examined the relationships between fire radiative power (FRP), its temporal integral (fire radiative energy - FRE), and net primary productivity (NPP) using 16 years of data from the MOderate Resolution Imaging Spectrometer (MODIS) for 15 large fires in western United States coniferous forests. The greatest NPP post-fire loss occurred 1 year post-fire and ranged from -67 to -312 g C m-2 yr-1 (-13 to -54 %) across all fires. Forests dominated by fire-resistant species (species that typically survive low-intensity fires) experienced the lowest relative NPP reductions compared to forests with less resistant species. Post-fire NPP in forests that were dominated by fire-susceptible species were not as sensitive to FRP or FRE, indicating that NPP in these forests may be reduced to similar levels regardless of fire intensity. Conversely, post-fire NPP in forests dominated by fire-resistant and mixed species decreased with increasing FRP or FRE. In some cases, this dose-response relationship persisted for more than a decade post-fire, highlighting a legacy effect of fire intensity on post-fire C dynamics in these forests.
Numerical simulation on behaviour of timber-concrete composite beams in fire
NASA Astrophysics Data System (ADS)
Du, Hao; Hu, Xiamin; Zhang, Bing; Minli, Yao
2017-08-01
This paper established sequentially coupled thermal-mechanical models of timber--concrete composite (TCC) beams by finite element software ANSYS to investigate the fire resistance of TCC beam. Existing experimental results were used to verify the coupled thermal-mechanical model. The influencing parameters consisted of the width of timber beam, the thickness of the concrete slab and the timber board. Based on the numerical results, the effects of these parameters on fire resistance of TCC beams were investigated in detail. The results showed that modeling results agreed well with test results, and verified the reliability of the finite element model. The width of the timber beam had a significant influence on the fire resistance of TCC beams. The fire resistance of TCC beams would be enhanced by increasing the width of timber beam, the thickness of concrete slab and the timber board.
Candidate materials for advanced fire-resistant photovoltaic modules
NASA Technical Reports Server (NTRS)
Sugimura, R. S.; Otth, D. H.; Ross, R. G., Jr.; Arnett, J. C.; Samuelson, G.
1985-01-01
A cooperative, cost-sharing research effort to develop a technology base required to construct fire-ratable photovoltaic modules has resulted in the identification of several high-temperature, back-surface candidate materials capable of raising the fire-resistance of modules using hydrocarbon encapsulants to Class A and B levels. Advanced experimental module configurations have been developed using back surfaces consisting of Kapton, Tedlar laminates, metal-foils, and fiberglass materials with high-temperature coatings. Test results (October 1984; March 1985; May 1985; and October 1985) indicate that several of these advanced module configurations are capable of achieving Class B fire-resistance levels, while a few configurations can achieve Class A levels. The paper summarizes activities to date, discussing flammability failure mechanisms, time-temperature profiles, and results of Block V environmental exposure tests of a candidate material suitable for both Class B and Class A fire-resistance levels.
2012-01-01
Background Breeding of fire blight resistant scions and rootstocks is a goal of several international apple breeding programs, as options are limited for management of this destructive disease caused by the bacterial pathogen Erwinia amylovora. A broad, large-effect quantitative trait locus (QTL) for fire blight resistance has been reported on linkage group 3 of Malus ‘Robusta 5’. In this study we identified markers derived from putative fire blight resistance genes associated with the QTL by integrating further genetic mapping studies with bioinformatics analysis of transcript profiling data and genome sequence databases. Results When several defined E.amylovora strains were used to inoculate three progenies from international breeding programs, all with ‘Robusta 5’ as a common parent, two distinct QTLs were detected on linkage group 3, where only one had previously been mapped. In the New Zealand ‘Malling 9’ X ‘Robusta 5’ population inoculated with E. amylovora ICMP11176, the proximal QTL co-located with SNP markers derived from a leucine-rich repeat, receptor-like protein ( MxdRLP1) and a closely linked class 3 peroxidase gene. While the QTL detected in the German ‘Idared’ X ‘Robusta 5’ population inoculated with E. amylovora strains Ea222_JKI or ICMP11176 was approximately 6 cM distal to this, directly below a SNP marker derived from a heat shock 90 family protein gene ( HSP90). In the US ‘Otawa3’ X ‘Robusta5’ population inoculated with E. amylovora strains Ea273 or E2002a, the position of the LOD score peak on linkage group 3 was dependent upon the pathogen strains used for inoculation. One of the five MxdRLP1 alleles identified in fire blight resistant and susceptible cultivars was genetically associated with resistance and used to develop a high resolution melting PCR marker. A resistance QTL detected on linkage group 7 of the US population co-located with another HSP90 gene-family member and a WRKY transcription factor previously associated with fire blight resistance. However, this QTL was not observed in the New Zealand or German populations. Conclusions The results suggest that the upper region of ‘Robusta 5’ linkage group 3 contains multiple genes contributing to fire blight resistance and that their contributions to resistance can vary depending upon pathogen virulence and other factors. Mapping markers derived from putative fire blight resistance genes has proved a useful aid in defining these QTLs and developing markers for marker-assisted breeding of fire blight resistance. PMID:22471693
NASA Astrophysics Data System (ADS)
Mustapa, S. A. S.; Ramli Sulong, N. H.
2017-06-01
This research deals with contribution of hybrid fillers with palm oil clinker (POC) as a novel bio-filler in solvent-borne intumescent fire protective coating for steel. The hybrid fillers with POC were mixed in appropriate amount of additives and acrylic binder to produce the intumescent coatings. The intumescent coatings were characterized by using Bunsen burner test, surface spread of flame, thermogravimetric analysis, field emission scanning electron microscopy, static immersion and Instron micro tester equipment. Specimen with POC as a single filler has significantly enhanced the fire protection performances of the intumescent coating due to the high thermal stability of POC, where less than 10% of temperature different when compared to specimens with hybrid fillers. From the flame spread classification, class 1 is the best classification while Class 4 is the worst and considered high risk. All specimens was classified as class 1 since the final spread of flame was less than 165 mm. For hybrid fillers composition, specimen consist of POC/Al(OH)3/TiO2 has significantly improved the water resistance of the coating due to the low solubility of Al(OH)3 in water, while specimen contain of Mg(OH)2 had higher mechanical strength due to the strong bonding between the metal surface and acrylic binder/Mg(OH)2 filler. It was found that coating with the incorporation of all hybrid fillers gives excellent fire protection performance with good thermal stability, water resistance and mechanical properties. It can be concluded that, the selection of appropriate composition of fillers and binder in intumescent coating was highly influence the intumescent coating performance.
Xue, Gang; Song, Wen-qi; Li, Shu-chao
2015-01-01
In order to achieve the rapid identification of fire resistive coating for steel structure of different brands in circulating, a new method for the fast discrimination of varieties of fire resistive coating for steel structure by means of near infrared spectroscopy was proposed. The raster scanning near infrared spectroscopy instrument and near infrared diffuse reflectance spectroscopy were applied to collect the spectral curve of different brands of fire resistive coating for steel structure and the spectral data were preprocessed with standard normal variate transformation(standard normal variate transformation, SNV) and Norris second derivative. The principal component analysis (principal component analysis, PCA)was used to near infrared spectra for cluster analysis. The analysis results showed that the cumulate reliabilities of PC1 to PC5 were 99. 791%. The 3-dimentional plot was drawn with the scores of PC1, PC2 and PC3 X 10, which appeared to provide the best clustering of the varieties of fire resistive coating for steel structure. A total of 150 fire resistive coating samples were divided into calibration set and validation set randomly, the calibration set had 125 samples with 25 samples of each variety, and the validation set had 25 samples with 5 samples of each variety. According to the principal component scores of unknown samples, Mahalanobis distance values between each variety and unknown samples were calculated to realize the discrimination of different varieties. The qualitative analysis model for external verification of unknown samples is a 10% recognition ration. The results demonstrated that this identification method can be used as a rapid, accurate method to identify the classification of fire resistive coating for steel structure and provide technical reference for market regulation.
USDA-ARS?s Scientific Manuscript database
Since its first report almost 200 years ago, fire blight, caused by the gram negative bacterium Erwinia amylovora, has threatened apple and pear production globally. Identifying novel genes and their functional alleles is a prerequisite to developing apple cultivars with enhanced fire blight resist...
14 CFR 23.853 - Passenger and crew compartment interiors.
Code of Federal Regulations, 2010 CFR
2010-01-01
... constructed of at least fire resistant materials and must contain fires likely to occur in it under normal use... Design and Construction Fire Protection § 23.853 Passenger and crew compartment interiors. For each compartment to be used by the crew or passengers: (a) The materials must be at least flame-resistant; (b...
NASA Technical Reports Server (NTRS)
Anderson, R. A.; Arnold, D. B.; Johnson, G. A.; Tustin, E. A.
1978-01-01
A test was conducted to evaluate the fire containment characteristics of a Boeing 747 lavatory module. Results showed that the fire was contained within the lavatory during the 30-minute test period with the door closed. The resistance of the lavatory wall and ceiling panels and general lavatory construction to burn-through under the test conditions was demonstrated.
M. Forbes Boyle; Roy L. Hedden; Thomas A. Waldrop
2004-01-01
The southern pine beetle ( Dendroctonus frontalis Zimm.) is considered one of the most aggressive insect pests in the Southern United States. Resistance to southern pine beetle infestations in southern pines depends largely on oleoresin flow rate and total flow. Treatments, such as prescribed fire and thinning, can be used to reduce stand infestation susceptibil-ity by...
Development and testing of advanced fire-resistant photovoltaic modules
NASA Technical Reports Server (NTRS)
Sugimura, R. S.; Otth, D. H.; Ross, R. G., Jr.
1985-01-01
The evaluation of back-surface materials flammability in order to identify fire resistant module designs is examined. The fire test apparatus, burning-brand test sequence, and spread-of-flame test sequence are described. Video recordings and time-temperature profiles of module back surfaces are utilized to study the flammability failure mechanism and identify high-temperature materials. A table of flammability test results for various module designs is provided. The data reveals that 2-mil kapton, fiberglass cloth coated or impregnated with a material to plug pores, and metal foil back-surface materials achieve class A and B fire-resistance levels, and are applicable for photovoltaic module designs.
Fire-Retardant and Thermally Insulating Phenolic-Silica Aerogels.
Yu, Zhi-Long; Yang, Ning; Apostolopoulou-Kalkavoura, Varvara; Qin, Bing; Ma, Zhi-Yuan; Xing, Wei-Yi; Qiao, Chan; Bergström, Lennart; Antonietti, Markus; Yu, Shu-Hong
2018-04-16
Energy efficient buildings require materials with a low thermal conductivity and a high fire resistance. Traditional organic insulation materials are limited by their poor fire resistance and inorganic insulation materials are either brittle or display a high thermal conductivity. Herein we report a mechanically resilient organic/inorganic composite aerogel with a thermal conductivity significantly lower than expanded polystyrene and excellent fire resistance. Co-polymerization and nanoscale phase separation of the phenol-formaldehyde-resin (PFR) and silica generate a binary network with domain sizes below 20 nm. The PFR/SiO 2 aerogel can resist a high-temperature flame without disintegration and prevents the temperature on the non-exposed side from increasing above the temperature critical for the collapse of reinforced concrete structures. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Lock Wall Expedient Repair Demonstration Monitoring, John T. Myers Locks and Dam, Ohio River
2011-10-01
original condition. Complete confinement of the concrete within the armor appears to provide good resistance to impact and abrasion (Figure 29). ERDC... resistance to impact and abrasion . Synopsis General classifications of observed damage were described and, where repairs are considered necessary or...against abrasion , fire , and environmental attacks and to improve the adhesion to other construc- tion materials. For high-weatherproof performance
Dunivin, Taylor K.; Miller, Justine
2018-01-01
Arsenic (As), a toxic element, has impacted life since early Earth. Thus, microorganisms have evolved many As resistance and tolerance mechanisms to improve their survival outcomes given As exposure. We isolated As resistant bacteria from Centralia, PA, the site of an underground coal seam fire that has been burning since 1962. From a 57.4°C soil collected from a vent above the fire, we isolated 25 unique aerobic As resistant bacterial strains spanning seven genera. We examined their diversity, resistance gene content, transformation abilities, inhibitory concentrations, and growth phenotypes. Although As concentrations were low at the time of soil collection (2.58 ppm), isolates had high minimum inhibitory concentrations (MICs) of arsenate and arsenite (>300 mM and 20 mM respectively), and most isolates were capable of arsenate reduction. We screened isolates (PCR and sequencing) using 12 published primer sets for six As resistance genes (AsRGs). Genes encoding arsenate reductase (arsC) and arsenite efflux pumps (arsB, ACR3(2)) were present, and phylogenetic incongruence between 16S rRNA genes and AsRGs provided evidence for horizontal gene transfer. A detailed investigation of differences in isolate growth phenotypes across As concentrations (lag time to exponential growth, maximum growth rate, and maximum OD590) showed a relationship with taxonomy, providing information that could help to predict an isolate’s performance given As exposure in situ. Our results suggest that microbiological management and remediation of environmental As could be informed by taxonomically-linked As tolerance, potential for resistance gene transferability, and the rare biosphere. PMID:29370270
Low resistivity contacts to YBa2Cu3O(7-x) superconductors
NASA Technical Reports Server (NTRS)
Hsi, Chi-Shiung; Haertling, Gene H.
1991-01-01
Silver, gold, platinum, and palladium metals were investigated as electroding materials for the YBa2Cu3O(7-x) superconductors. Painting, embedding, and melting techniques were used to apply the electrodes. Contact resistivities were determined by: (1) type of electrode; (2) firing conditions; and (3) application method. Electrodes fired for long times exhibited lower contact resistivities than those fired for short times. Low-resistivity contacts were found for silver and gold electrodes. Silver, which made good ohmic contact to the YBa2Cu3O(7-x) superconductor with low contact resistivities was found to be the best electroding material among the materials evaluated in this investigation.
Fire Resistant Fuel for Military Compression Ignition Engines
2013-12-04
Turbo Diesel Maximum Power Output Figure 5. 6.5L Turbo Diesel Maximum Torque Output 40 60 80 100 120 140 160 180 1000 1200 1400 1600 1800 2000 2200...H2O & 250ppm) JP8-FRF AMA (5% H2O & 250ppm) UNCLASSIFIED 9 UNCLASSIFIED Figure 6. 6.5L Turbo Diesel Brake Specific Fuel Consumption From...mid-1980s, fire-resistant diesel fuel that self extinguished when ignited by an explosive projectile was developed. Chemically, this fire resistant
Carlsson, Fredrik; Edman, Mattias; Holm, Svante; Eriksson, Anna-Maria; Jonsson, Bengt Gunnar
2012-10-01
Forest fires have been the major stand-replacing/modifying disturbance in boreal forests. To adapt to fire disturbance, different strategies have evolved. This study focuses on wood fungi, and a specific adaptation to forest fire: increased heat resistance in their mycelia. Fifteen species of wood fungi were selected and a priori sorted in two groups according to their prevalence in fire-affected environments. The fungi were cultivated on fresh wood and exposed to 100, 140, 180, 220 °C for 5, 10, 15, 20 and 25 min. under laboratory conditions. A clear difference was found among the two groups. Species prevalent in fire-affected habitats had a much higher survival rate over all combinations of time and temperature compared to species associated with other environments. Thus, the results indicate that fire adaptation in terms of increased heat resistance in mycelia occurs in some species of wood fungi. Such adaptation will influence the ecology and population dynamics of wood fungi, as well as having implications for best practices during restoration fires. Copyright © 2012 The British Mycological Society. Published by Elsevier Ltd. All rights reserved.
'Sunrise': A new early maturing fire blight resistant pear cultivar
USDA-ARS?s Scientific Manuscript database
'Sunrise' is a new pear (Pyrus communis L.) cultivar released by the U.S. Department of Agriculture, Agricultural Research Service. It combines a high degree of resistance to fire blight with excellent fruit quality. The sources of resistance in the pedigree are the old American cultivar, 'Seckel'...
Code of Federal Regulations, 2010 CFR
2010-07-01
... other hanging materials that are made of non-combustible or flame-resistant fabric; (f) Use only... resistant; (g) Cooperate with GSA to develop and maintain fire prevention programs that provide the maximum... accident and fire prevention responsibilities of occupant agencies? 102-74.360 Section 102-74.360 Public...
46 CFR 72.05-10 - Type, location, and construction of fire control bulkheads and decks.
Code of Federal Regulations, 2010 CFR
2010-10-01
... public spaces with incombustible veneers and trim and fire resistant furnishings Staterooms and public spaces of 500 square feet or less with combustible furnishings and isolated storerooms Public spaces over... and all public spaces with incombustible veneers and trim and fire resistant furnishings 5 A-15 A-15 A...
Fire and the Design of Educational Buildings. Building Bulletin 7. Sixth Edition.
ERIC Educational Resources Information Center
Department of Education and Science, London (England).
This bulletin offers guidance on English school premises regulations applying to safety protection against fires in the following general areas: means of escape in case of fire; precautionary measures to prevent fire; fire warning systems and fire fighting; fire spreading speed; structures and materials resistant to fires; and damage control. It…
Stronger Fire-Resistant Epoxies
NASA Technical Reports Server (NTRS)
Fohlen, George M.; Parker, John A.; Kumar, Devendra
1988-01-01
New curing agent improves mechanical properties and works at lower temperature. Use of aminophenoxycyclotriphosphazene curing agents yields stronger, more heat- and fire-resistant epoxy resins. Used with solvent if necessary for coating fabrics or casting films.
Techno-economic requirements for composite aircraft components
NASA Technical Reports Server (NTRS)
Palmer, Ray
1993-01-01
The primary reason for use of composites is to save structural weight. A well designed composite aircraft structure will usually save 25-30 percent of a well designed metal structure. The weight savings then translates into improved performance of the aircraft in measures of greater payload, increased flying range or improved efficiency - less use of fuel. Composite materials offer technical advantages. Key technical advantages that composites offer are high stiffness, tailored strength capability, fatigue resistance, and corrosion resistance. Low thermal expansion properties produce dimensionally stable structures over a wide range of temperature. Specialty resin 'char' forming characteristics in a fire environment offer potential fire barrier application and safer aircraft. The materials and processes of composite fabrication offer the potential for lower cost structures in the near future. The application of composite materials to aircraft are discussed.
Space and Missile Systems Center Standard: Space Flight Pressurized Systems
2015-02-28
24 5.7.2 Fire Resistant Fluids ......................................................................................... 24 5.7.3...connections. 5.1.7 Threaded Parts [5.1.7-1] All threaded parts in components shall be securely locked to resist uncoupling forces by acceptable safe... Resistant Fluids [5.7.2-1] Fire resistant or flame proof hydraulic fluid shall be used where the system design can expose hydraulic fluid to potential
2013-07-18
are subject to damage and abrasion (figure 5). The use of an extension cord instead of fixed wiring creates the possibility of fire , electrical shock...Medical Clinic has an adjacent warehouse that is of a higher hazard and is not separated by 1-hour fire resistance rated construction. KMC 17-May...higher hazard and is not separated by 1-hour fire resistance rated construction. DynCorp NO Awaiting USG Decision DI has not received governmental
Schmitter, M; Lotze, G; Bömicke, W; Rues, S
2015-12-01
The purpose of this study was to assess the effect of surface treatment on the fracture resistance of zirconia-based all-ceramic anterior crowns. Sixty-four zirconia-based all-ceramic anterior crowns, veneered by use of a press-on technique, were produced. For 48 crowns intraoral adjustment was simulated (A-group), 16 crowns remained unadjusted (WA-group). The adjusted area was then treated in three ways: 1. no further surface treatment; 2. polishing, with irrigation, using polishers interspersed with diamond grit for ceramics; and 3. polishing and glaze firing. Half of the specimens were loaded until fracture in an universal testing device without artificial ageing; the other crowns underwent thermocycling and chewing simulation before ultimate-load testing. Explorative statistical analysis was performed by use of non-parametric and parametric tests. In addition, fracture-strength tests according to ISO 6872 were performed for veneer ceramic subjected to the different surface treatments. Finite element analysis was also conducted for the crowns, and surface roughness was measured. Crowns in the A-group were more sensitive to aging than crowns in the WA-group (p=0.038). Although both polishing and glaze firing slightly improved the fracture resistance of the specimens, the fracture resistance in the WA-group (initial fracture resistance (IFR): 652.0 ± 107.7N, remaining fracture resistance after aging (RFR): 560.6 ± 233.3N) was higher than the fracture resistance in the A-group (polished: IFR: 477.9 ± 108.8N, RFR: 386.0 ± 218.5N; glaze firing: IFR: 535.5 ± 128.0N, RFR: 388.6 ± 202.2N). Surface roughness without adjustment was Ra=0.1 μm; for adjustment but without further treatment it was Ra=1.4 μm; for adjustment and polishing it was Ra=0.3 μm; and for adjustment, polishing, and glazing it was Ra=0.6 μm. Stress distributions obtained by finite element analysis in combination with fracture strength tests showed that fractures most probably originated from the occlusal surface. To improve fracture resistance and reduce the incidence of failure, extensive occlusal adjustment of veneered anterior zirconia restorations should be avoided. Neither polishing nor glazing could restore the fracture resistance to the level maintained with unadjusted crowns. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Chen, Fei-Fei; Zhu, Ying-Jie; Chen, Feng; Dong, Li-Ying; Yang, Ri-Long; Xiong, Zhi-Chao
2018-04-24
Wallpaper with multiple functions, such as fire resistance and an automatic alarm in fire disasters, will be attractive for the interior decoration of houses. Herein, we report a smart fire alarm wallpaper prepared using fire-resistant inorganic paper based on ultralong hydroxyapatite nanowires (HNs) and graphene oxide (GO) thermosensitive sensors. At room temperature, the GO thermosensitive sensor is in a state of electrical insulation; however, it becomes electrically conductive at high temperatures. In a fire disaster, high temperature will rapidly remove the oxygen-containing groups of GO, leading to the transformation process of GO from an electrically insulated state into an electrically conductive one. In this way, the alarm lamp and alarm buzzer connected with the GO thermosensitive sensor will send out the alerts to people immediately for taking emergency actions. After the surface modification with polydopamine of GO (PGO), the sensitivity and flame retardancy of the GO thermosensitive sensor are further improved, resulting in a low responsive temperature (126.9 °C), fast response (2 s), and sustained working time in the flame (at least 5 min). Compared with combustible commercial wallpaper, the smart fire alarm wallpaper based on HNs and GO (or PGO) is superior owing to excellent nonflammability and high-temperature resistance of HNs, which can protect the GO (or PGO) thermosensitive sensor from the flames. The smart fire alarm wallpaper can be processed into various shapes, dyed with different colors, and printed with the commercial printer and thus has promising applications in high-safety interior decoration of houses.
Improved fire resistant radio frequency anechoic materials
NASA Technical Reports Server (NTRS)
Robinson, D. A.
1969-01-01
Protective, flameproof foam covering improves the resistance to fire and surface contamination of low-cost radio frequency absorbing and shielding anechoic materials. This promotes safety of operating personnel and equipment being tested in an otherwise combustible anechoic chamber.
2015-09-01
position unless so designated by other authorized documents. Citation of trade names in this report does not constitute an official endorsement or...project to design and develop a Fire Resistant (FR) and Heat Resistant (HR) sewing thread. The main goal of the project is to produce sewing threads made...addresses the design , development and testing of various Fire Resistant (FR)/Heat Resistant (HR) sewing threads for US Army applications. Such a sewing
1980-09-30
Aberdeen Proving Ground, Maryland, September 1976. 2. Weatherford, W.D., Jr., Fodor, G.E., Naegeli , D.W., Owens, E.C., Wright, B.R., and Schaekel, F.W...Weatherford, W.I)., Jr., Fodor, G.E., Naegeli , D.W., Owens, E.C., Wright, B.R., and Schaekel, F.W., "Development of Army Fire-Resistant Diesel Fuel," Interim
Study of coatings for improved fire and decay resistance of mine timbers
NASA Technical Reports Server (NTRS)
Baum, B.
1977-01-01
The purpose of this program was to find a fire- and rot-retardant polymer/fungicide reaction product for coating mine timbers. Fire-retardant polymers were screened as films and coatings on fir wood. Curable polyimide appeared to be flame retardant and evolved a minimum of fumes when exposed to a flame. Several organic and metal, low toxicity, fungicides were reacted with the polyimide in-situ on the wood. These coated samples were screened for fungus resistance. All formulations rated well - even the polyimide film without additives was fungicidal. The fir wood control itself resisted internal damage during the ten weeks of fungus exposure. A more severe test for fungus resistance will be required.
Fire resistant nuclear fuel cask
Heckman, Richard C.; Moss, Marvin
1979-01-01
The disclosure is directed to a fire resistant nuclear fuel cask employing reversibly thermally expansible bands between adjacent cooling fins such that normal outward flow of heat is not interfered with, but abnormal inward flow of heat is impeded or blocked.
NASA Technical Reports Server (NTRS)
Stoica, Steln; Sebe, Mircea Octavian
1987-01-01
A comparative experimental study on the application of various tests for the evaluation of the fire-resistant properties of plastic materials is presented. On the basis of the results obtained conclusions are drawn on the advantages and disadvantages of the methods used, and a preferred test method is picked, i.e., the introduction of fire retardant materials into the polymers.
Validation of a Polyimide Foam Model for Use in Transmission Loss Applications
NASA Technical Reports Server (NTRS)
Hong, Kwanwoo; Bolton, J. Stuart; Cano, Roberto J.; Weiser, Erik S.; Jensen, Brian J.; Silcox, Rich; Howerton, Brian M.; Maxon, John; Wang, Tongan; Lorenzi, Tyler
2010-01-01
The work described in this paper was focused on the use of a new polyimide foam in a double wall sound transmission loss application. Recall that polyimide foams are functionally attractive, compared to polyurethane foams, for example, owing to their fire resistance. The foam considered here was found to have a flow resistivity that was too high for conventional acoustical applications, and as a result, it was processed by partial crushing to lower the flow resistivity into an acceptable range. Procedures for measuring the flow resistivity and Young s modulus of the material have been described, as was an inverse characterization procedure for estimating the remaining Biot parameters based on standing wave tube measurements of transmission loss and absorption coefficient. The inverse characterization was performed using a finite element model implementation of the Biot poro-elastic material theory. Those parameters were then used to predict the sound transmission loss of a double panel system lined with polyimide foam, and the predictions were compared with full-scale transmission loss measurements. The agreement between the two was reasonable, especially in the high and low frequency limits; however, it was found that the SEA model resulted in an under-prediction of the transmission loss in the mid-frequency range. Nonetheless, it was concluded that the performance of polyimide foam could be predicted using conventional poro-elastic material models and that polyimide foam may offer an attractive alternative to other double wall linings in certain situations: e.g., when fire resistance is a key issue. Future work will concentrate on reducing the density of the foam to values similar to those used in current aircraft sidewall treatments, and developing procedures to improve the performance of the foam in transmission loss applications.
Geneva apple rootstock performance in New York state and progress in commercialization
USDA-ARS?s Scientific Manuscript database
A number of new apple rootstocks from the Cornell/USDA apple rootstock breeding project, located at Geneva NY which are resistant to the bacterial disease fire blight (Erwinia amylovora) are rapidly becoming available. Some named rootstock genotypes from this program have previously been tested in s...
30 CFR 75.1107-13 - Approval of other fire suppression devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-13 Approval of... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approval of other fire suppression devices. 75...
14 CFR 25.1731 - Powerplant and APU fire detector system: EWIS.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Powerplant and APU fire detector system... Systems (EWIS) § 25.1731 Powerplant and APU fire detector system: EWIS. (a) EWIS that are part of each fire or overheat detector system in a fire zone must be fire-resistant. (b) No EWIS component of any...
14 CFR 25.1731 - Powerplant and APU fire detector system: EWIS.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Powerplant and APU fire detector system... Systems (EWIS) § 25.1731 Powerplant and APU fire detector system: EWIS. (a) EWIS that are part of each fire or overheat detector system in a fire zone must be fire-resistant. (b) No EWIS component of any...
14 CFR 25.1731 - Powerplant and APU fire detector system: EWIS.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Powerplant and APU fire detector system... Systems (EWIS) § 25.1731 Powerplant and APU fire detector system: EWIS. (a) EWIS that are part of each fire or overheat detector system in a fire zone must be fire-resistant. (b) No EWIS component of any...
14 CFR 25.1731 - Powerplant and APU fire detector system: EWIS.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Powerplant and APU fire detector system... Systems (EWIS) § 25.1731 Powerplant and APU fire detector system: EWIS. (a) EWIS that are part of each fire or overheat detector system in a fire zone must be fire-resistant. (b) No EWIS component of any...
14 CFR 25.1731 - Powerplant and APU fire detector system: EWIS.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Powerplant and APU fire detector system... Systems (EWIS) § 25.1731 Powerplant and APU fire detector system: EWIS. (a) EWIS that are part of each fire or overheat detector system in a fire zone must be fire-resistant. (b) No EWIS component of any...
Fire blight resistance in wild accessions of Malus sieversii
USDA-ARS?s Scientific Manuscript database
Fire blight (Erwinia amylovora) is a devastating bacterial disease in apple that results in severe economic losses. Epidemics are becoming more common as susceptible cultivars and rootstocks are being planted, and control is becoming more difficult as antibiotic-resistant strains develop. Resistan...
Resistance to wildfire and early regeneration in natural broadleaved forest and pine plantation
NASA Astrophysics Data System (ADS)
Proença, Vânia; Pereira, Henrique M.; Vicente, Luís
2010-11-01
The response of an ecosystem to disturbance reflects its stability, which is determined by two components: resistance and resilience. We addressed both components in a study of early post-fire response of natural broadleaved forest ( Quercus robur, Ilex aquifolium) and pine plantation ( Pinus pinaster, Pinus sylvestris) to a wildfire that burned over 6000 ha in NW Portugal. Fire resistance was assessed from fire severity, tree mortality and sapling persistence. Understory fire resistance was similar between forests: fire severity at the surface level was moderate to low, and sapling persistence was low. At the canopy level, fire severity was generally low in broadleaved forest but heterogeneous in pine forest, and mean tree mortality was significantly higher in pine forest. Forest resilience was assessed by the comparison of the understory composition, species diversity and seedling abundance in unburned and burned plots in each forest type. Unburned broadleaved communities were dominated by perennial herbs (e.g., Arrhenatherum elatius) and woody species (e.g., Hedera hibernica, Erica arborea), all able to regenerate vegetatively. Unburned pine communities presented a higher abundance of shrubs, and most dominant species relied on post-fire seeding, with some species also being able to regenerate vegetatively (e.g., Ulex minor, Daboecia cantabrica). There were no differences in diversity measures in broadleaved forest, but burned communities in pine forest shared less species and were less rich and diverse than unburned communities. Seedling abundance was similar in burned and unburned plots in both forests. The slower reestablishment of understory pine communities is probably explained by the slower recovery rate of dominant species. These findings are ecologically relevant: the higher resistance and resilience of native broadleaved forest implies a higher stability in the maintenance of forest processes and the delivery of ecosystem services.
46 CFR 78.45-1 - When required.
Code of Federal Regulations, 2012 CFR
2012-10-01
... the following plans: (1) General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means...
46 CFR 78.45-1 - When required.
Code of Federal Regulations, 2010 CFR
2010-10-01
... the following plans: (1) General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means...
46 CFR 78.45-1 - When required.
Code of Federal Regulations, 2011 CFR
2011-10-01
... the following plans: (1) General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means...
46 CFR 78.45-1 - When required.
Code of Federal Regulations, 2013 CFR
2013-10-01
... the following plans: (1) General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means...
46 CFR 78.45-1 - When required.
Code of Federal Regulations, 2014 CFR
2014-10-01
... the following plans: (1) General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means...
Fire Resistance of Large-Scale Cross-Laminated Timber Panels
NASA Astrophysics Data System (ADS)
Henek, Vladan; Venkrbec, Václav; Novotný, Miloslav
2017-12-01
Wooden structures are increasingly being used in the construction of residential buildings. A common and often published reason to avoid wooden structures is their insufficient fire resistance, which reduces bearing capacity. For this reason, composite sandwich structures began to be designed to eliminate this drawback, as well as others. Recently, however, the trend is for a return to the original, wood-only variant and a search is underway for new technical means of improving the properties of such structures. Many timber structure technologies are known, but structures made from cross-laminated timber (CLT) panels have been used very often in recent years. CLT panels, also known as X-LAM, are currently gaining popularity in Europe. In the case of CLT panels composed of several layers of boards, they can be said to offer a certain advantage in that after the surface layer of a board has burnt and the subsurface layer has dried, oxygen is not drawn to the unburned wood for further combustion and thus the burning process ceases. CLT panels do not need to be specially modified or coated with fire resistant materials, although they are usually lined with gypsum-fibre fire resistant boards due to guidelines set out in the relevant standards. This paper presents a new method for the assessment of load-bearing perimeter walls fabricated from CLT panels without the use of an inner fire-retardant lining to ensure fire resistance at the level required by European standards (i.e. those harmonized for the Czech construction industry). The calculations were verified through laboratory tests which show that better parameters can be achieved during the classification of structures from the fire resistance point of view. The aim of the article is to utilize the results of assessment and testing by an accredited laboratory in order to demonstrate the possibilities of using CLT panels for the construction of multistorey as well as multi-purpose buildings in the Czech Republic.
Fire Resistance of Geopolymer Concretes
2010-03-21
1 Project report – Grant FA23860814096, "Fire resistance of geopolymer concretes" – J. Provis, University of Melbourne 1. Background and...experimental program This project provided funding for us to carry out fire testing of geopolymer concrete specimens and associated laboratory...testing. The focus of this report will be the outcomes of the series of pilot-scale (4’×4’×6”) tests on geopolymer concrete panels, which were conducted
Rootstock-regulated gene expression patterns associated with fire blight resistance in apple
USDA-ARS?s Scientific Manuscript database
Background: Desirable apple varieties are clonally propagated by grafting vegetative scions onto rootstocks. Rootstocks influence many phenotypic traits of the scion, including resistance to pathogens such as Erwinia amylovora, which causes fire blight, the most serious bacterial disease of apple....
Design and Test Requirements for Space Flight Pressurized Systems
2014-11-26
5.7.2 Fire Resistant Fluids ......................................................................................... 24 5.7.3 Accumulators...5.1.7 Threaded Parts [5.1.7-1] All threaded parts in components shall be securely locked to resist uncoupling forces by acceptable safe design...event of force balance on both inlet ports may occur, thus causing the shutoff valve to restrict flow from the outlet port. 5.7.2 Fire Resistant
46 CFR 97.36-1 - When required.
Code of Federal Regulations, 2012 CFR
2012-10-01
... the vessel the following plans: (a) General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means...
46 CFR 97.36-1 - When required.
Code of Federal Regulations, 2013 CFR
2013-10-01
... the vessel the following plans: (a) General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means...
46 CFR 97.36-1 - When required.
Code of Federal Regulations, 2014 CFR
2014-10-01
... the vessel the following plans: (a) General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means...
J. Stephen Brewer
2015-01-01
Although repeated fires are generally thought to reduce competition, direct tests of this hypothesis are rare. Furthermore, recent theory predicts that fires can increase competitive effects of fireresistant species on fire-sensitive species and thus create stable assemblages dominated by the former. In this study, I quantified competition between saplings of fire-...
Progression and Behavior of the Canoe Fire in Coast Redwood
Hugh Scanlon
2007-01-01
Lightning caused fires occur in coast redwood forests, but large fires have been rare since the 1930s. Coast redwood (Sequoia sempervirens) is considered fire resistant. In 2003, the Canoe Fire, a lightning fire started in an old-growth redwood stand in Humboldt Redwoods State Park, burned 5,554 hectares (13,774 acres) before it was contained. Fuel...
Joseph Marschall; Michael Stambaugh; Benjamin Jones; Richard Guyette; Patrick Brose; Daniel C. Dey
2016-01-01
Many fire-adapted ecosystems in the northeastern U.S. are converting to fire-intolerant vegetation communities due to fire suppression in the 20th century. Prescribed fire and other vegetation management activities that increase resilience and resistance to global changes are increasingly being implemented, particularly on public lands. For many fire-dependent...
46 CFR 132.130 - Fire stations.
Code of Federal Regulations, 2011 CFR
2011-10-01
... discharge both solid stream and water spray. (h) Each pipe and fire hydrant must be placed so that the fire... or other suitable corrosion-resistant material and comply with NFPA 1963. (k) Each fire hydrant must... 46 Shipping 4 2011-10-01 2011-10-01 false Fire stations. 132.130 Section 132.130 Shipping COAST...
USDA-ARS?s Scientific Manuscript database
1. Fire, herbivory and their interaction influence plant community dynamics. However, little is known about the influence of pre-fire herbivory on post-fire plant community response, particularly long-term resilience to post-fire exotic plant invasion in areas that historically experienced limited ...
NASA Astrophysics Data System (ADS)
Suzuki, Kuniko; Sugawa, Osami; Yamagishi, Akira; Miyagi, Katsunori; Kamiya, Kyoko
Silicone liquid has the high performance in fire safety showing fire resistance by self-extinguishing, and that is less environmentally pollutant compared with mineral oil. Applicability of silicone liquid of 20cSt to transformers was investigated from the view point of the correlation of ignition time with critical radiant heat flux. The same tests were carried out using a mineral oil and synthetic ester oil. The basic properties of silicone liquid (20cSt) obtained from the series of the tests were verified in its application as a less-flammable transformer fluid.
Sharon Hood; Barbara Bentz; Ken Gibson; Kevin Ryan; Gregg DeNitto
2007-01-01
Douglas-fir has life history traits that greatly enhance resistance to injury from fire, thereby increasing post-fire survival rates. Tools for predicting the probability of tree mortality following fire are important components of both pre-fire planning and post-fire management efforts. Using data from mixed-severity wildfire in Montana and Wyoming, Hood and Bentz (...
Code of Federal Regulations, 2010 CFR
2010-10-01
... the requirements for fire pumps, fire mains, and fire hoses on towing vessels? By April 29, 2005, you... from both branches of the fitting if the highest hydrant has a Siamese fitting, at a pitot-tube... of corrosion-resistant material capable of providing a solid stream and a spray pattern. (f) You must...
30 CFR 35.20 - Autogenous-ignition temperature test.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., EVALUATION, AND APPROVAL OF MINING PRODUCTS FIRE-RESISTANT HYDRAULIC FLUIDS Test Requirements § 35.20... (alundum or equivalent) cylinder 5 inches in internal diameter and 5 inches in height; a transite-ring top... is obtained. (d) Appraisal of test. A fluid shall be considered fire-resistant, according to the test...
30 CFR 35.20 - Autogenous-ignition temperature test.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., EVALUATION, AND APPROVAL OF MINING PRODUCTS FIRE-RESISTANT HYDRAULIC FLUIDS Test Requirements § 35.20... (alundum or equivalent) cylinder 5 inches in internal diameter and 5 inches in height; a transite-ring top... is obtained. (d) Appraisal of test. A fluid shall be considered fire-resistant, according to the test...
30 CFR 35.20 - Autogenous-ignition temperature test.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., EVALUATION, AND APPROVAL OF MINING PRODUCTS FIRE-RESISTANT HYDRAULIC FLUIDS Test Requirements § 35.20... (alundum or equivalent) cylinder 5 inches in internal diameter and 5 inches in height; a transite-ring top... is obtained. (d) Appraisal of test. A fluid shall be considered fire-resistant, according to the test...
30 CFR 35.20 - Autogenous-ignition temperature test.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., EVALUATION, AND APPROVAL OF MINING PRODUCTS FIRE-RESISTANT HYDRAULIC FLUIDS Test Requirements § 35.20... (alundum or equivalent) cylinder 5 inches in internal diameter and 5 inches in height; a transite-ring top... is obtained. (d) Appraisal of test. A fluid shall be considered fire-resistant, according to the test...
46 CFR 164.006-4 - Inspection and testing.
Code of Federal Regulations, 2013 CFR
2013-10-01
... attachments shall be incorporated in the samples. Each sample shall be heated in a furnace whose temperature... minutes—60 percent light transmission. 60 minutes—50 percent light transmission. (c) Fire resistance and integrity tests. (1) A sample of each thickness submitted shall be tested for fire resistance and integrity...
46 CFR 164.006-4 - Inspection and testing.
Code of Federal Regulations, 2012 CFR
2012-10-01
... attachments shall be incorporated in the samples. Each sample shall be heated in a furnace whose temperature... minutes—60 percent light transmission. 60 minutes—50 percent light transmission. (c) Fire resistance and integrity tests. (1) A sample of each thickness submitted shall be tested for fire resistance and integrity...
46 CFR 164.006-4 - Inspection and testing.
Code of Federal Regulations, 2011 CFR
2011-10-01
... attachments shall be incorporated in the samples. Each sample shall be heated in a furnace whose temperature... minutes—60 percent light transmission. 60 minutes—50 percent light transmission. (c) Fire resistance and integrity tests. (1) A sample of each thickness submitted shall be tested for fire resistance and integrity...
46 CFR 164.006-4 - Inspection and testing.
Code of Federal Regulations, 2014 CFR
2014-10-01
... attachments shall be incorporated in the samples. Each sample shall be heated in a furnace whose temperature... minutes—60 percent light transmission. 60 minutes—50 percent light transmission. (c) Fire resistance and integrity tests. (1) A sample of each thickness submitted shall be tested for fire resistance and integrity...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-06
... DEPARTMENT OF DEFENSE Defense Acquisition Regulations System 48 CFR Part 225 RIN 0750-AH22 Defense Federal Acquisition Regulation Supplement; Fire-Resistant Fiber for Production of Military Uniforms (DFARS Case 2011-D021) AGENCY: Defense Acquisition Regulations System, Department of Defense (DoD). ACTION...
Code of Federal Regulations, 2010 CFR
2010-10-01
... bronze or equivalent metal. (e) All fittings on fire hose shall be of brass, copper, or other suitable corrosion resistant metal. (f) A length of fire hose shall be attached to each fire hydrant at all times... 46 Shipping 4 2010-10-01 2010-10-01 false Fire hose. 105.35-15 Section 105.35-15 Shipping COAST...
Reintroducing fire in regenerated dry forests following stand-replacing wildfire.
David W. Peterson; Paul F. Hessburg; Brion Salter; Kevin M. James; Matthew C. Dahlgreen; John A. Barnes
2007-01-01
Prescribed fire use may be effective for increasing fire resilience in young coniferous forests by reducing surface fuels, modifying overstory stand structure, and promoting development of large trees of fire resistant species. Questions remain, however, about when and how to reintroduce fire in regenerated forests, and to what end. We studied the effects of spring...
Chapter 6: Fire damage of wood structures
B. Kukay; R.H. White; F. Woeste
2012-01-01
Depending on the severity, fire damage can compromise the structural integrity of wood structures such as buildings or residences. Fire damage of wood structures can incorporate several models that address (1) the type, cause, and spread of the fire, (2) the thermal gradients and fire-resistance ratings, and (3) the residual load capacity (Figure 6.1). If there is a...
Behavior of Insulated Carbon-FRP-Strengthened RC Beams Exposed to Fire
NASA Astrophysics Data System (ADS)
Sayin, B.
2014-09-01
There are two main approaches to improving the fire resistance of fiber-reinforced polymer (FRP) systems. While the most common method is to protect or insulate the FRP system, an other way is to use fibers and resins with a better fire performance. This paper presents a numerical investigation into the five protection behavior of insulated carbon-fiber-reinforced-polymer (CFRP)-strengthened reinforced concrete (RC) beams. The effects of external loading and thermal expansion of materials at elevated temperatures are taken into consideration in a finite-element model. The validity of the numerical model is demonstrated with results from an existing experimental study on insulated CFRP-strengthened RC beams. Conclusions of this investigation are employed to predict the structural behavior of CFRP-strengthened concrete structures.
Miller, Richard F.; Chambers, Jeanne C.; Pyke, David A.; Pierson, Fred B.; Williams, C. Jason
2013-01-01
This review synthesizes the state of knowledge on fire effects on vegetation and soils in semi-arid ecosystems in the Great Basin Region, including the central and northern Great Basin and Range, Columbia River Basin, and the Snake River Plain. We summarize available literature related to: (1) the effects of environmental gradients, ecological site, and vegetation characteristics on resilience to disturbance and resistance to invasive species; (2) the effects of fire on individual plant species and communities, biological soil crusts, seed banks, soil nutrients, and hydrology; and (3) the role of fire severity, fire versus fire surrogate treatments, and post-fire grazing in determining ecosystem response. From this, we identify knowledge gaps and present a framework for predicting plant successional trajectories following wild and prescribed fires and fire surrogate treatments. Possibly the three most important ecological site characteristics that influence a site’s resilience (ability of the ecological site to recover from disturbance) and resistance to invasive species are soil temperature/moisture regimes and the composition and structure of vegetation on the ecological site just prior to the disturbance event.
Fire characteristics associated with firefighter injury on large federal wildland fires.
Britton, Carla; Lynch, Charles F; Torner, James; Peek-Asa, Corinne
2013-02-01
Wildland fires present many injury hazards to firefighters. We estimate injury rates and identify fire-related factors associated with injury. Data from the National Interagency Fire Center from 2003 to 2007 provided the number of injuries in which the firefighter could not return to his or her job assignment, person-days worked, and fire characteristics (year, region, season, cause, fuel type, resistance to control, and structures destroyed). We assessed fire-level risk factors of having at least one reported injury using logistic regression. Negative binomial regression was used to examine incidence rate ratios associated with fire-level risk factors. Of 867 fires, 9.5% required the most complex management and 24.7% required the next-highest level of management. Fires most often occurred in the western United States (82.8%), during the summer (69.6%), caused by lightening (54.9%). Timber was the most frequent fuel source (40.2%). Peak incident management level, person-days of exposure, and the fire's resistance to control were significantly related to the odds of a fire having at least one reported injury. However, the most complex fires had a lower injury incidence rate than less complex fires. Although fire complexity and the number of firefighters were associated with the risk for at least one reported injury, the more experienced and specialized firefighting teams had lower injury incidence. Copyright © 2013 Elsevier Inc. All rights reserved.
30 CFR 75.1107-8 - Fire suppression devices; extinguishant supply systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-8... liquid chemical to protect attended equipment shall: (1) Be maintained at a pressure consistent with the...
30 CFR 75.1107-8 - Fire suppression devices; extinguishant supply systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-8... liquid chemical to protect attended equipment shall: (1) Be maintained at a pressure consistent with the...
NASA Astrophysics Data System (ADS)
Pedersen, J. R.; Holte, T. A.; Johansen, E.
Cables with improved fire resistance and flame retardance have been developed. They will continue to function at least 3 hours even at temperatures up to 1000 C and do not propagate fire when tested according to IEC 332 part 3 1982, category A. Made with halogenfree materials they give off no corrosive gases and very little visible smoke in cases of fire. Cables are made for power, signal and instrument installations in hospitals, high rise buildings, railroad cars, subways, on board ship, oil rigs and oil production platforms. The offshore cables are specially constructed to withstand the rugged climatic conditions in the North Sea area.
NASA Technical Reports Server (NTRS)
Enders, J. H.
1978-01-01
NASA's aviation safety technology program examines specific safety problems associated with atmospheric hazards, crash-fire survival, control of aircraft on runways, human factors, terminal area operations hazards, and accident factors simulation. While aircraft occupants are ultimately affected by any of these hazards, their well-being is immediately impacted by three specific events: unexpected turbulence encounters, fire and its effects, and crash impact. NASA research in the application of laser technology to the problem of clear air turbulence detection, the development of fire resistant materials for aircraft construction, and to the improvement of seats and restraint systems to reduce crash injuries are reviewed.
Code of Federal Regulations, 2010 CFR
2010-10-01
... equivalent fire-resistant material; and (2) Fitted with a commercial garden-hose nozzle of high-grade bronze..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS FIRE-PROTECTION EQUIPMENT Fire Main § 132... equipped with a fire main that complies with this subpart. (b) Each vessel of less than 100 gross tons and...
Design of structures against fire. Civil engineering/buildings, architecture
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anchor, R.D.; Malhotra, H.L.; Purkiss, J.A.
1986-01-01
The book covers structural design criteria, along with background theory on fire protection methods for structures from a variety of materials, including timber, steel, and concrete. Research on the behavior of structural materials in the presence of fire is highlighted, and the need for fire-resistant materials is addressed.
14 CFR 121.275 - Fire detectors.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Fire detectors. 121.275 Section 121.275..., FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.275 Fire detectors. Fire detectors must be made and installed in a manner that assures their ability to resist, without failure, all...
14 CFR 121.275 - Fire detectors.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Fire detectors. 121.275 Section 121.275..., FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.275 Fire detectors. Fire detectors must be made and installed in a manner that assures their ability to resist, without failure, all...
14 CFR 121.275 - Fire detectors.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Fire detectors. 121.275 Section 121.275..., FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.275 Fire detectors. Fire detectors must be made and installed in a manner that assures their ability to resist, without failure, all...
14 CFR 121.275 - Fire detectors.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Fire detectors. 121.275 Section 121.275..., FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.275 Fire detectors. Fire detectors must be made and installed in a manner that assures their ability to resist, without failure, all...
14 CFR 121.275 - Fire detectors.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Fire detectors. 121.275 Section 121.275..., FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.275 Fire detectors. Fire detectors must be made and installed in a manner that assures their ability to resist, without failure, all...
Nano-fibrillated cellulose-hydroxyapatite based composite foams with excellent fire resistance.
Guo, Wenwen; Wang, Xin; Zhang, Ping; Liu, Jiajia; Song, Lei; Hu, Yuan
2018-09-01
Thermally insulating materials made from renewable resources are desirable for energy efficient buildings. Traditional petroleum-derived insulating materials such as rigid polyurethane foam and expanded polystyrene display poor flame retardancy and inorganic insulating materials such as silica aerogel are fragile. Herein, we reported a facile approach to prepare cellulose nanofiber (CNF)-hydroxyapatite (HAP) composite foam by a simple freeze-drying process. The resultant HAP-CNF composite foams showed a thermal conductivity in the range of 38.5-39.1 mW/(m K) and very low peak heat release rate (20.4 kW/m 2 ) and total heat release (1.21 MJ/m 2 ). Vertical burning tests also manifested excellent fire resistance and self-extinguishing behaviours. Considering the excellent fire resistance of this composite foam, it is of significance to fire safety solution for buildings insulating materials. Copyright © 2018 Elsevier Ltd. All rights reserved.
Fuel moisture influences on fire-altered carbon in masticated fuels: An experimental study
Nolan W. Brewer; Alistair M.S. Smith; Jeffery A. Hatten; Philip E. Higuera; Andrew T. Hudak; Roger D. Ottmar; Wade T. Tinkham
2013-01-01
Biomass burning is a significant contributor to atmospheric carbon emissions but may also provide an avenue in which fire-affected ecosystems can accumulate carbon over time, through the generation of highly resistant fire-altered carbon. Identifying how fuel moisture, and subsequent changes in the fire behavior, relates to the production of fire-altered carbon is...
Effectiveness of fire-retardant treatments for shingles after 10 years of outdoor weathering
S. L. LeVan; C. A. Holmes
Some building codes require wood shingles to be fire-retardant treated. Because exterior fire-retardant treatments are subjected to weathering, treatment durability and leach resistance are critical for insuring adequate fire protection. We examined the effectiveness of various fire-retardant treatments on wood after 0, 2, 5, and 10 years of outdoor exposure. We used a...
Resistance of the boreal forest to high burn rates.
Héon, Jessie; Arseneault, Dominique; Parisien, Marc-André
2014-09-23
Boreal ecosystems and their large carbon stocks are strongly shaped by extensive wildfires. Coupling climate projections with records of area burned during the last 3 decades across the North American boreal zone suggests that area burned will increase by 30-500% by the end of the 21st century, with a cascading effect on ecosystem dynamics and on the boreal carbon balance. Fire size and the frequency of large-fire years are both expected to increase. However, how fire size and time since previous fire will influence future burn rates is poorly understood, mostly because of incomplete records of past fire overlaps. Here, we reconstruct the length of overlapping fires along a 190-km-long transect during the last 200 y in one of the most fire-prone boreal regions of North America to document how fire size and time since previous fire will influence future fire recurrence. We provide direct field evidence that extreme burn rates can be sustained by a few occasional droughts triggering immense fires. However, we also show that the most fire-prone areas of the North American boreal forest are resistant to high burn rates because of overabundant young forest stands, thereby creating a fuel-mediated negative feedback on fire activity. These findings will help refine projections of fire effect on boreal ecosystems and their large carbon stocks.
Resistance of the boreal forest to high burn rates
Héon, Jessie; Arseneault, Dominique; Parisien, Marc-André
2014-01-01
Boreal ecosystems and their large carbon stocks are strongly shaped by extensive wildfires. Coupling climate projections with records of area burned during the last 3 decades across the North American boreal zone suggests that area burned will increase by 30–500% by the end of the 21st century, with a cascading effect on ecosystem dynamics and on the boreal carbon balance. Fire size and the frequency of large-fire years are both expected to increase. However, how fire size and time since previous fire will influence future burn rates is poorly understood, mostly because of incomplete records of past fire overlaps. Here, we reconstruct the length of overlapping fires along a 190-km-long transect during the last 200 y in one of the most fire-prone boreal regions of North America to document how fire size and time since previous fire will influence future fire recurrence. We provide direct field evidence that extreme burn rates can be sustained by a few occasional droughts triggering immense fires. However, we also show that the most fire-prone areas of the North American boreal forest are resistant to high burn rates because of overabundant young forest stands, thereby creating a fuel-mediated negative feedback on fire activity. These findings will help refine projections of fire effect on boreal ecosystems and their large carbon stocks. PMID:25201981
NASA Technical Reports Server (NTRS)
Hillenbrand, L. J.; Wray, J. A.
1973-01-01
The plans for the present series of full-scale experimental fires were initiated at the suggestion of NASA following the presentation of a film and discussion illustrating Battelle-Columbus' recent work in fire research. That film showed bedroom-type fires carried out as a part of a program to determine the influence of the cyclic characteristics of real fires under limited ventilation on the burning and pyrolysis properties of the room furnishings. A new series of fires was suggested by NASA designed to show the performance of new fire resistant and fire retardant materials by providing comparative fire and smoldering environmental conditions. More recently, the goal for the new series of fires was written in a meeting with NASA personnel and others at Battelle on May 3 and 4, 1972. The goal was as follows: To establish the need for special materials of improved fire safety in domiciliary settings of public concern, and to assess, in a professionally acceptable manner, the potential of materials arising from the new space-age technology for this purpose. It was anticipated that some new materials arising from the space-age technology and not yet available through conventional commercial channels might provide significant improvements in fire safety if the best of the commercially available materials showed important shortcomings in this area. It was the intent of this program to assess the benefits that could accrue from the use of these new materials. Fire safety is a matter requiring the evaluation of a number of factors. For example, fire resistance and fire spread, visibility during the fire, toxicity of evolved gases, and the fire-fighting problem that is created must be evaluated before the relative hazard can be assessed. The plan of the program provided for sampling and instrumentation to evaluate these factors, consistent with the goal of technological utilization that has been specified. Arrangements were made with the Columbus Fire Department to use an existing six-story concrete building', designed and used as a fire training tower, as the site for the experimental fires. The visual evidence provided by TV and photographic coverage of the four experimental room fires showed clearly that the rooms responded very differently to a common ignition condition. In particular: (1) The Typical room, furnished from conventional retail sources, ignited easily and burned rapidly so that after 8 minutes the contents of the room were nearly destroyed. (2) The Improved room, furnished with materials selected as being among the best commercially available, showed substantial improvement over the Typical room in that there was slower fire spread. However, the relatively complete destruction of the room contents that resulted, and the large amounts of smoke, made it clear that substantial further improvements were needed. This fire was stopped after 29 minutes. (3) The Space-age room, furnished completely with new materials that were not yet commercially available, did not ignite under the common ignition condition and soon demonstrated the substantial improvement in fire resistance available for those components close to the ignition source. A second and larger ignition arrangement showed that this room can burn, but the difficulty with which this was brought about confirmed the improved fire resistance available with use of these materials. (4) The Mixed room ensemble, furnished with 'materials identical to the Typical room except for the substitution of the bed from the Space-age room, illustrated the improvement in control of fire spread available by careful placement of fire materials in the important paths of fire development of an otherwise ordinary room. The most significant hazards at early times in each fire were due to the rapid rise in heat flux and the abrupt obscuration of vision by smoke. The most consistent toxicity hazard was due to CO and its importance would depend on the ability of the occupant to survive the initial heat and smoke menace which characterized each fire room. Other gases and vapors were shown to reach hazardous levels in certain fire rooms and, again, their significance to an occupant, would relate to the times in which such hazards occurred, and probably to the synergistic nature of the hazard arising from mixtures of such gases. Fire retardant items in the room are caused to pyrolyze by the heat of burning from other items in the room and so contribute to combustible and toxic vapor accumulations, even though they may not have entered into the burning process. This effect of a mixture of combustible materials to produce burning and pyrolysis not characteristic of any one item individually we have chosen to call the "ensemble effect". Further full-scale fire trials may be expected to show the significant changes that control the burning and pyrolytic processes and in that event a programmed fire chamber should be developed to yield realistic laboratory results.
Fire resistant aircraft seat program
NASA Technical Reports Server (NTRS)
Fewell, L. A.
1979-01-01
Foams, textiles, and thermoformable plastics were tested to determine which materials were fire retardant, and safe for aircraft passenger seats. Seat components investigated were the decorative fabric cover, slip covers, fire blocking layer, cushion reinforcement, and the cushioning layer.
30 CFR 75.1107-3 - Fire suppression devices; approved components; installation requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-3... agency approved by the Secretary. (b) Where used, pressure vessels shall conform with the requirements of...
30 CFR 75.1107-3 - Fire suppression devices; approved components; installation requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-3... agency approved by the Secretary. (b) Where used, pressure vessels shall conform with the requirements of...
30 CFR 75.1107-3 - Fire suppression devices; approved components; installation requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-3... agency approved by the Secretary. (b) Where used, pressure vessels shall conform with the requirements of...
30 CFR 75.1107-3 - Fire suppression devices; approved components; installation requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-3... agency approved by the Secretary. (b) Where used, pressure vessels shall conform with the requirements of...
30 CFR 75.1107-3 - Fire suppression devices; approved components; installation requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-3... agency approved by the Secretary. (b) Where used, pressure vessels shall conform with the requirements of...
Analytical methods for determining fire resistance of timber members
Robert H. White
2008-01-01
The fire resistance ratings of wood members and assemblies, as of other materials, have traditionally been obtained by testing the assembly in a furnace in accordance with ASTM International (ASTM) Standard E119, International Organization for Standardization (ISO) Standard 834, and similar standards. These ratings are published in listings, such as Underwriters...
Biological Efficacy of Permethrin Treatment on New U.S. Military Uniforms
USDA-ARS?s Scientific Manuscript database
The United States Army and United States Marine Corps (USMC) are fielding uniforms that incorporate fire resistant fibers into the uniform material. For the U.S. Army, the change in uniform composition to produce the Fire-Resistant Army Combat Uniform (FRACU) results in a uniform that does not reta...
Development of a Fire-Resistant Anti-Sweat Submarine Hull Insulation Based on Fiber Glass Materials.
1983-09-01
CHART NATIONAL BUREAU OF STANDARDS-1963-A6w " ;’’ ..J’ d’ ,.,, -,,,.. ,.- -,. . 11111, , .. b,, I - - -.. .,. , .. . ..°.. III. . . ,Lm’ Johns ... Manville Research & Development Center DEVELOPMENT OF A FIRE-RESISTANT ANTI-SWEAT SUBMARINE HULL INSULATION BASED ON FIBER *" GLASS MATERIALS Oct icrb iz Ic
Highly Sensitive Sensors Based on Metal-Oxide Nanocolumns for Fire Detection.
Lee, Kwangjae; Shim, Young-Seok; Song, Young Geun; Han, Soo Deok; Lee, Youn-Sung; Kang, Chong-Yun
2017-02-07
A fire detector is the most important component in a fire alarm system. Herein, we present the feasibility of a highly sensitive and rapid response gas sensor based on metal oxides as a high performance fire detector. The glancing angle deposition (GLAD) technique is used to make the highly porous structure such as nanocolumns (NCs) of various metal oxides for enhancing the gas-sensing performance. To measure the fire detection, the interface circuitry for our sensors (NiO, SnO₂, WO₃ and In₂O₃ NCs) is designed. When all the sensors with various metal-oxide NCs are exposed to fire environment, they entirely react with the target gases emitted from Poly(vinyl chlorides) (PVC) decomposed at high temperature. Before the emission of smoke from the PVC (a hot-plate temperature of 200 °C), the resistances of the metal-oxide NCs are abruptly changed and SnO₂ NCs show the highest response of 2.1. However, a commercial smoke detector did not inform any warning. Interestingly, although the NiO NCs are a p -type semiconductor, they show the highest response of 577.1 after the emission of smoke from the PVC (a hot-plate temperature of 350 °C). The response time of SnO₂ NCs is much faster than that of a commercial smoke detector at the hot-plate temperature of 350 °C. In addition, we investigated the selectivity of our sensors by analyzing the responses of all sensors. Our results show the high potential of a gas sensor based on metal-oxide NCs for early fire detection.
Land uses, fire, and invasion: Exotic annual Bromus and human dimensions
Pyke, David A.; Chambers, Jeanne C.; Beck, Jeffrey L.; Brooks, Matthew L.; Mealor, Brian A.
2016-01-01
Human land uses are the primary cause of the introduction and spread of exotic annual Bromusspecies. Initial introductions were likely linked to contaminated seeds used by homesteading farmers in the late 1880s and early 1900s. Transportation routes aided their spread. Unrestricted livestock grazing from the 1800s through the mid-1900s reduced native plant competitors leaving large areas vulnerable to Bromus dominance. Ecosystems with cooler and moister soils tend to have greater potential to recover from disturbances (resilience) and to be more resistant to Bromusinvasion and dominance. Warmer and drier ecosystems are less resistant to Bromus and are threatened by altered fire regimes which can lead to Bromus dominance, impacts to wildlife, and alternative stable states. Native Americans used fire for manipulating plant communities and may have contributed to the early dominance of Bromus in portions of California. Fire as a tool is now limited to site preparation for revegetation in most ecosystems where Bromus is a significant problem. Once Bromus dominates, breaking annual grass/fire cycles requires restoring fire-tolerant perennial grasses and forbs, which can compete with Bromus and resist its dominance. Current weed management policies often lack regulations to prevent further expansion of Bromus. Research is needed on how and where livestock grazing might help increase perennial grass and forb cover and density to create ecosystems that are more resistant to Bromus. Also, studies are needed to ascertain the role, if any, of oil and gas development in contributing to the spread of Bromus.
NASA Technical Reports Server (NTRS)
Meyer, Marit E.
2015-01-01
Fire safety in the indoor spacecraft environment is concerned with a unique set of fuels which are designed to not combust. Unlike terrestrial flaming fires, which often can consume an abundance of wood, paper and cloth, spacecraft fires are expected to be generated from overheating electronics consisting of flame resistant materials. Therefore, NASA prioritizes fire characterization research for these fuels undergoing oxidative pyrolysis in order to improve spacecraft fire detector design. A thermal precipitator designed and built for spacecraft fire safety test campaigns at the NASA White Sands Test Facility (WSTF) successfully collected an abundance of smoke particles from oxidative pyrolysis. A thorough microscopic characterization has been performed for ten types of smoke from common spacecraft materials or mixed materials heated at multiple temperatures using the following techniques: SEM, TEM, high resolution TEM, high resolution STEM and EDS. Resulting smoke particle morphologies and elemental compositions have been observed which are consistent with known thermal decomposition mechanisms in the literature and chemical make-up of the spacecraft fuels. Some conclusions about particle formation mechanisms are explored based on images of the microstructure of Teflon smoke particles and tar ball-like particles from Nomex fabric smoke.
Schlathölter, Ina; Jänsch, Melanie; Flachowsky, Henryk; Broggini, Giovanni Antonio Lodovico; Hanke, Magda-Viola; Patocchi, Andrea
2018-06-01
The approach presented here can be applied to reduce the time needed to introduce traits from wild apples into null segregant advanced selections by one-fourth. Interesting traits like resistances to pathogens are often found within the wild apple gene pool. However, the long juvenile phase of apple seedlings hampers the rapid introduction of these traits into new cultivars. The rapid crop cycle breeding approach used in this paper is based on the overexpression of the birch (Betula pendula) MADS4 transcription factor in apple. Using the early flowering line T1190 and 'Evereste' as source of the fire blight resistance (Fb_E locus), we successfully established 18 advanced selections of the fifth generation in the greenhouse within 7 years. Fifteen individuals showed the habitus expected of a regular apple seedling, while three showed very short internodes. The null segregants possessing a regular habitus maintained the high level of fire blight resistance typical for 'Evereste'. Using SSR markers, we estimated the percentage of genetic drag from 'Evereste' still associated with Fb_E on linkage group 12 (LG12). Eight out of the 18 selections had only 4% of 'Evereste' genome left. Since genotypes carrying the apple scab resistance gene Rvi6 and the fire blight resistance QTL Fb_F7 were used as parents in the course of the experiments, these resistances were also identified in some of the null segregants. One seedling is particularly interesting as, beside Fb_E, it also carries Fb_F7 heterozygously and Rvi6 homozygously. If null segregants obtained using this method will be considered as not genetically modified in Europe, as is already the case in the USA, this genotype could be a very promising parent for breeding new fire blight and scab-resistant apple cultivars in European apple breeding programs.
Effect of Experimentally Manipulated Fire Regimes on the Response of Forests to Drought
NASA Astrophysics Data System (ADS)
Refsland, T. K.; Knapp, B.; Fraterrigo, J.
2017-12-01
Climate change is expected to increase drought stress in many forests and alter fire regimes. Fire can reduce tree density and thus competition for limited water, but the effects of changing fire regimes on forest productivity during drought remain poorly understood. We measured the annual ring-widths of adult oak (Quercus spp.) trees in Mark Twain National Forest, Missouri USA that experienced unburned, annual or periodic (every 4 years) surface fire treatments from 1951 - 2015. Severe drought events were identified using the BILJOU water balance model. We determined the effect of fire treatment on stand-level annual growth rates as well as stand-level resistance and resilience to drought, defined as the drought-induced reduction in growth and post-drought recovery in growth, respectively. During favorable wet years, annual and periodic fire treatments reduced annual growth rates by approximately 10-15% relative to unburned controls (P < 0.001). Stand-level growth rates declined 22-40% during drought events (P < 0.001), but fire-driven changes to stand basal area had no effect on the resistance or resilience of trees to drought. The decline in annual growth rates of burned stands during favorable wet years was likely caused by increased nitrogen (N) limitation in burned plots. After 60 years of treatment, burned plots experienced 30% declines in total soil N relative to unburned plots. Our finding that drought resistance and resilience were similar across all treatments suggest that fire-driven reductions in stand density may have negligible effects on soil moisture availability during drought. Our results highlight that climate-fire interactions can have important long-term effects on forest productivity.
46 CFR 28.380 - General structural fire protection.
Code of Federal Regulations, 2010 CFR
2010-10-01
... accommodation space must be separated from machinery and fuel tank spaces by a fire resistant boundary which... 46 Shipping 1 2010-10-01 2010-10-01 false General structural fire protection. 28.380 Section 28..., 1991, and That Operate With More Than 16 Individuals on Board § 28.380 General structural fire...
Terminology and biology of fire scars in selected central hardwoods
Kevin T. Smith; Elaine Kennedy Sutherland
2001-01-01
Dendrochronological analysis of fire scars requires tree survival of fire exposure. Trees survive fire exposure by: (1) avoidance of injury through constitutive protection and (2) induced defense. Induced defenses include (a) compartmentalization processes that resist the spread of injury and infection and (b) closure processes that restore the continuity of the...
Madrean pine-oak forest in Arizona: past dynamics, present problems
Andrew M. Barton
2008-01-01
This paper synthesizes research on presettlement dynamics and modern disruption of Madrean pine-oak forests in Arizona. In response to surface fires characteristic of presettlement times, pines were fire resistant, exhibiting high top-survival, whereas oaks were fire resilient, exhibiting lower top-survival but pronounced resprouting. Thus, low-severity fire favors...
Development of assembly techniques for fire resistant aircraft interior panels
NASA Technical Reports Server (NTRS)
Lee, S. C. S.
1978-01-01
Ten NASA Type A fire resistant aircraft interior panels were fabricated and tested to develop assembly techniques. These techiques were used in the construction of a full scale lavatory test structure for flame propagation testing. The Type A panel is of sandwich construction consisting of Nomex honeycomb filled with quinone dioxime foam, and bismaleimide/glass face sheets bonded to the core with polyimide film adhesive. The materials selected and the assembly techniques developed for the lavatory test structure were designed for obtaining maximum fire containment with minimum smoke and toxic emission.
A ballistic evaluation of the impact resistance of spectacle lens materials.
Oliver, A L; Chou, B R
1993-10-01
The impact resistance of chemically and thermally hardened glass lenses of 2.2- and 3.0-mm thicknesses was evaluated using a ballistic test. Each lens was edged and mounted into a spectacle frame, which was placed on a standard headform. A 6.5-mm steel ball was fired from an air gun at the center of the lens at increasing speeds until the lens broke. The multiple impact data were used to plot cumulative breakage curves. We found that heat-treated photochromic glass and heat-treated crown glass fail at similar missile speeds and that chemical treating considerably improves the impact resistance of crown glass but not of photochromic glass. The poorer performance of photochromic lenses indicates that they should not be prescribed when optimal impact protection is required. Plastic lenses show superior performance.
Heat-resistant anemometers for fire research
John R. Murray; Clive M. Countryman
1968-01-01
Heat-resistant anemometers have been developed for measuring horizontal and vertical air flow in fire behavior studies. The anemometers will continue to produce data as long as the anemometer body is less than 650°F. They can survive brief immersion in flame without major damage. These air-flow sensors have aluminum bodies and rotor hubs and stainless steel...
Fire resistance of engineered wood rim board products.
Robert H. White
2003-01-01
Engineered wood products, such as oriented strandboard, laminated veneer lumber, and other composite wood products, are being used more often in construction. This includes use as rim boards, which are the components around the perimeter of a floor assembly. This situation has increased the need for information about the fire resistance of these products. In this study...
14 CFR 29.853 - Compartment interiors.
Code of Federal Regulations, 2010 CFR
2010-01-01
... towels, paper, or waste must be at least fire-resistant and must have means for containing possible fires... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Design and Construction Fire Protection § 29.853... and nondecorative coated fabrics, leather, trays and galley furnishings, electrical conduit, thermal...
Zhang, Taolin; Zhou, Xiaodong; Yang, Lizhong
2016-03-05
This work investigated experimentally and theoretically the fire hazards of thermal-insulation materials used in diesel locomotives under different radiation heat fluxes. Based on the experimental results, the critical heat flux for ignition was determined to be 6.15 kW/m² and 16.39 kW/m² for pure polyurethane and aluminum-polyurethane respectively. A theoretical model was established for both to predict the fire behaviors under different circumstances. The fire behavior of the materials was evaluated based on the flashover and the total heat release rate (HRR). The fire hazards levels were classified based on different experimental results. It was found that the fire resistance performance of aluminum-polyurethane is much better than that of pure-polyurethane under various external heat fluxes. The concentration of toxic pyrolysis volatiles generated from aluminum-polyurethane materials is much higher than that of pure polyurethane materials, especially when the heat flux is below 50 kW/m². The hazard index HI during peak width time was proposed based on the comprehensive impact of time and concentrations. The predicted HI in this model coincides with the existed N-gas and FED models which are generally used to evaluate the fire gas hazard in previous researches. The integrated model named HNF was proposed as well to estimate the fire hazards of materials by interpolation and weighted average calculation.
Zhang, Taolin; Zhou, Xiaodong; Yang, Lizhong
2016-01-01
This work investigated experimentally and theoretically the fire hazards of thermal-insulation materials used in diesel locomotives under different radiation heat fluxes. Based on the experimental results, the critical heat flux for ignition was determined to be 6.15 kW/m2 and 16.39 kW/m2 for pure polyurethane and aluminum-polyurethane respectively. A theoretical model was established for both to predict the fire behaviors under different circumstances. The fire behavior of the materials was evaluated based on the flashover and the total heat release rate (HRR). The fire hazards levels were classified based on different experimental results. It was found that the fire resistance performance of aluminum-polyurethane is much better than that of pure-polyurethane under various external heat fluxes. The concentration of toxic pyrolysis volatiles generated from aluminum-polyurethane materials is much higher than that of pure polyurethane materials, especially when the heat flux is below 50 kW/m2. The hazard index HI during peak width time was proposed based on the comprehensive impact of time and concentrations. The predicted HI in this model coincides with the existed N-gas and FED models which are generally used to evaluate the fire gas hazard in previous researches. The integrated model named HNF was proposed as well to estimate the fire hazards of materials by interpolation and weighted average calculation. PMID:28773295
Edge attachment study for fire-resistant canopies
NASA Technical Reports Server (NTRS)
Wintermute, G. E.
1982-01-01
Twenty-two resin systems were evaluated in laminate form for possible use as edge attachment material for fire-resistant canopies. The evaluation uncovered an unexpected development when the laminates were subjected to an intense flame: (1) the high-heat-resistant materials could withstand the flame test quite well, but experienced rapid heat transfer through the test specimen; (2) the laminates which exhibited a low rate of heat transfer were materials which lost strength rapidly in the presence of the flame by decomposition, delamination, and blistering.
Fire Resistant Composite Closed Cell Foam and Nonwoven Textiles for Tents and Shelters
2006-01-01
when heated. The heat causes the plasticizer to dissolve in the PVC to form a flexible, plasticized PVC film . The foam and/or fabric surfaces were...PVC/NBR AF-U9D foam formed a char and only the edge of the material was damaged. These data suggested that burn-through resistance , in addition to...AFRL-ML-TY-TR-2006-4571 FIRE RESISTANT COMPOSITE CLOSED CELL FOAM AND NONWOVEN TEXTILES FOR TENTS AND SHELTERS Stephen C. Davis
Seed Pubescence and Shape Modulate Adaptive Responses to Fire Cues
Gómez-González, Susana; Ojeda, Fernando; Torres-Morales, Patricio; Palma, Jazmín E.
2016-01-01
Post-fire recruitment by seeds is regarded as an adaptive response in fire-prone ecosystems. Nevertheless, little is known about which heritable seed traits are functional to the main signals of fire (heat and smoke), thus having the potential to evolve. Here, we explored whether three seed traits (pubescence, dormancy and shape) and fire regime modulate seed response to fire cues(heat and smoke). As a model study system, we used Helenium aromaticum (Asteraceae), a native annual forb from the Chilean matorral, where fires are anthropogenic. We related seed trait values with fitness responses (germination and survival) after exposure to heat-shock and smoke experimental treatments on seeds from 10 H. aromaticum wild populations. We performed a phenotypic selection experiment to examine the relationship of seed traits with post-treatment fitness within a population (adaptive hypothesis). We then explored whether fire frequency in natural habitats was associated with trait expression across populations, and with germination and survival responses to experimental fire-cues. We found that populations subjected to higher fire frequency had, in average, more rounded and pubescent seeds than populations from rarely burned areas. Populations with more rounded and pubescent seeds were more resistant to 80°C heat-shock and smoke treatments.There was correlated selection on seed traits: pubescent-rounded or glabrouscent-elongated seeds had the highest probability of germinating after heat-shock treatments. Seed pubescence and shape in H. aromaticum are heritable traits that modulate adaptive responses to fire. Our results provide new insights into the process of plant adaptation to fire and highlight the relevance of human-made fires as a strong evolutionary agent in the Anthropocene. PMID:27438267
Seed Pubescence and Shape Modulate Adaptive Responses to Fire Cues.
Gómez-González, Susana; Ojeda, Fernando; Torres-Morales, Patricio; Palma, Jazmín E
2016-01-01
Post-fire recruitment by seeds is regarded as an adaptive response in fire-prone ecosystems. Nevertheless, little is known about which heritable seed traits are functional to the main signals of fire (heat and smoke), thus having the potential to evolve. Here, we explored whether three seed traits (pubescence, dormancy and shape) and fire regime modulate seed response to fire cues(heat and smoke). As a model study system, we used Helenium aromaticum (Asteraceae), a native annual forb from the Chilean matorral, where fires are anthropogenic. We related seed trait values with fitness responses (germination and survival) after exposure to heat-shock and smoke experimental treatments on seeds from 10 H. aromaticum wild populations. We performed a phenotypic selection experiment to examine the relationship of seed traits with post-treatment fitness within a population (adaptive hypothesis). We then explored whether fire frequency in natural habitats was associated with trait expression across populations, and with germination and survival responses to experimental fire-cues. We found that populations subjected to higher fire frequency had, in average, more rounded and pubescent seeds than populations from rarely burned areas. Populations with more rounded and pubescent seeds were more resistant to 80°C heat-shock and smoke treatments.There was correlated selection on seed traits: pubescent-rounded or glabrouscent-elongated seeds had the highest probability of germinating after heat-shock treatments. Seed pubescence and shape in H. aromaticum are heritable traits that modulate adaptive responses to fire. Our results provide new insights into the process of plant adaptation to fire and highlight the relevance of human-made fires as a strong evolutionary agent in the Anthropocene.
Resistance of eastern hardwood stems to fire injury and damage
Kevin T. Smith; Elaine Kennedy Sutherland
2006-01-01
This paper reviews the protective features and defensive responses of eastern hardwood species exposed to fire. Trees survive fire through protective features such as thick bark and the induced defenses of compartmentalization. Dissection of trees exposed to prescribed fire in an oak forest in southern Ohio highlights the need to distinguish between bark scorch, stem...
McGhee, Gayle C; Sundin, George W
2011-02-01
The emergence and spread of streptomycin-resistant strains of Erwinia amylovora in Michigan has necessitated the evaluation of new compounds effective for fire blight control. The aminoglycoside antibiotic kasugamycin (Ks) targets the bacterial ribosome and is particularly active against E. amylovora. The efficacy of Ks formulated as Kasumin 2L for control of fire blight was evaluated in six experiments conducted over four field seasons in our experimental orchards in East Lansing, MI. Blossom blight control was statistically equivalent to the industry standard streptomycin in all experiments. E. amylovora populations remained constant on apple flower stigmas pretreated with Kasumin and were ≈100-fold lower than on stigmas treated with water. Kasumin applied to apple trees in the field also resulted in a 100-fold reduced total culturable bacterial population compared with trees treated with water. We performed a prospective analysis of the potential for kasugamycin resistance (Ks(R)) development in E. amylovora which focused on spontaneous resistance development and acquisition of a transferrable Ks(R) gene. In replicated lab experiments, the development of spontaneous resistance in E. amylovora to Ks at 250 or 500 ppm was not observed when cells were directly plated on medium containing high concentrations of the antibiotic. However, exposure to increasing concentrations of Ks in media (initial concentration 25 μg ml(-1)) resulted in the selection of Ks resistance (at 150 μg ml(-1)) in the E. amylovora strains Ea110, Ea273, and Ea1189. Analysis of mutants indicated that they harbored mutations in the kasugamycin target ksgA gene and that all mutants were impacted in relative fitness observable through a reduced growth rate in vitro and decreased virulence in immature pear fruit. The possible occurrence of a reservoir of Ks(R) genes in orchard environments was also examined. Culturable gram-negative bacteria were surveyed from six experimental apple orchards that had received at least one Kasumin application. In total, 401 Ks(R) isolates (42 different species) were recovered from apple flowers and leaves and orchard soil samples. Although we have not established the presence of a transferrable Ks(R) gene in orchard bacteria, the frequency, number of species, and presence of Ks(R) enterobacterial species in orchard samples suggests the possible role of nontarget bacteria in the future transfer of a Ks(R) gene to E. amylovora. Our data confirm the importance of kasugamycin as an alternate antibiotic for fire blight management and lay the groundwork for the development and incorporation of resistance management strategies.
Impact of Fire Resistant Fuel Blends on Compression Ignition Engine Performance
2011-07-01
EFFECTS ON ENGINE PERFORMANCE FRF blends were tested in the CAT C7 and GEP 6.5L(T) engines to determine the effects of FRF on engine ...impact on efficiency of the Stanadyne rotary injection pump used in the GEP 6.5L(T) engine , thus largely effecting its power output when varying... exhaust backpressure . Emissions are sampled from an exhaust probe installed between the engine and exhaust system butterfly valve.
von Seidlein, Lorenz; Dondorp, Arjen
2015-06-01
The emergence and spread of antimalarial resistance has been a major liability for malaria control. The spread of chloroquine-resistant Plasmodium falciparum strains had catastrophic consequences for people in malaria-endemic regions, particularly in sub-Saharan Africa. The recent emergence of artemisinin-resistant P. falciparum strains is of highest concern. Current efforts to contain artemisinin resistance have yet to show success. In the absence of more promising plans, it has been suggested to eliminate falciparum malaria from foci of artemisinin resistance using a multipronged approach, including mass drug administrations. The use of mass drug administrations is controversial as it increases drug pressure. Based on current knowledge it is difficult to conceptualize how targeted malaria elimination could contribute to artemisinin resistance, provided a full treatment course is ensured.
Control of Phasic Firing by a Background Leak Current in Avian Forebrain Auditory Neurons
Dagostin, André A.; Lovell, Peter V.; Hilscher, Markus M.; Mello, Claudio V.; Leão, Ricardo M.
2015-01-01
Central neurons express a variety of neuronal types and ion channels that promote firing heterogeneity among their distinct neuronal populations. Action potential (AP) phasic firing, produced by low-threshold voltage-activated potassium currents (VAKCs), is commonly observed in mammalian brainstem neurons involved in the processing of temporal properties of the acoustic information. The avian caudomedial nidopallium (NCM) is an auditory area analogous to portions of the mammalian auditory cortex that is involved in the perceptual discrimination and memorization of birdsong and shows complex responses to auditory stimuli We performed in vitro whole-cell patch-clamp recordings in brain slices from adult zebra finches (Taeniopygia guttata) and observed that half of NCM neurons fire APs phasically in response to membrane depolarizations, while the rest fire transiently or tonically. Phasic neurons fired APs faster and with more temporal precision than tonic and transient neurons. These neurons had similar membrane resting potentials, but phasic neurons had lower membrane input resistance and time constant. Surprisingly phasic neurons did not express low-threshold VAKCs, which curtailed firing in phasic mammalian brainstem neurons, having similar VAKCs to other NCM neurons. The phasic firing was determined not by VAKCs, but by the potassium background leak conductances, which was more prominently expressed in phasic neurons, a result corroborated by pharmacological, dynamic-clamp, and modeling experiments. These results reveal a new role for leak currents in generating firing diversity in central neurons. PMID:26696830
Mackay, Christopher E; Vivanco, Stephanie N; Yeboah, George; Vercellone, Jeff
2016-09-01
There have been concerns that fire-derived acid gases could aggravate thermal burns for individuals wearing synthetic flame retardant garments. A comparative risk assessment was performed on three commercial flame retardant materials with regard to relative hazards associated with acidic combustion gases to skin during a full engulfment flash fire event. The tests were performed in accordance with ASTM F1930 and ISO 13506: Standard Test Method for Evaluation of Flame Resistant Clothing for Protection against Fire Simulations Using an Instrumented Manikin. Three fire retardant textiles were tested: an FR treated cotton/nylon blend, a low Protex(®) modacrylic blend, and a medium Protex(®) modacrylic blend. The materials, in the form of whole body coveralls, were subjected to propane-fired flash conditions of 84kW/m(2) in a full sized simulator for a duration of either 3 or 4s. Ion traps consisting of wetted sodium carbonate-impregnated cellulose in Teflon holders were placed on the chest and back both above and under the standard undergarments. The ion traps remained in position from the time of ignition until 5min post ignition. Results indicated that acid deposition did increase with modacrylic content from 0.9μmol/cm(2) for the cotton/nylon, to 12μmol/cm(2) for the medium modacrylic blend. The source of the acidity was dominated by hydrogen chloride. Discoloration was inversely proportional to the amount of acid collected on the traps. A risk assessment was performed on the potential adverse impact of acid gases on both the skin and open wounds. The results indicated that the deposition and dissolution of the acid gases in surficial fluid media (perspiration and blood plasma) resulted in an increase in acidity, but not sufficient to induce irritation/skin corrosion or to cause necrosis in open third degree burns. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Identification of QTLs for resistance to fire blight (Erwinia amylovora) in Malus sieversii
USDA-ARS?s Scientific Manuscript database
Malus sieversii (Ms) is the progenitor of the domestic apple. Ms PI613981 is elite scion material collected at a xerophytic site in Kazakhstan from a tree free of disease and insect damage. The F1 family GMAL4593 (‘Royal Gala’ X PI631981) is segregating for resistance to both apple scab and fire bl...
Nadir Ayrilmis; S Nami Kartal; Theodore L. Laufenberg; Jerrold E. Winandy; Robert H. White
2005-01-01
This study evaluated the effects of a number of chemicals on the physical and mechanical properties and fire, decay, and termite resistance of oriented strandboard (OSB) panels. Disodium octaborate tetrahydrate (DOT), boric acid (BA), melamine phosphate (MP), and a BA/DOT mixture were sprayed onto the furnish at varying concentrations. The panels were tested for...
Light weight fire resistant graphite composites
NASA Technical Reports Server (NTRS)
Kourtides, D. A.; Parker, J. A.; Hsu, M. T. S.
1986-01-01
Composite structures with a honeycomb core and characterized by lightweight and excellent fire resistance are provided. These sandwich structures employ facesheets made up of bismaleimide-vinyl styrylpyridine copolymers with fiber reinforcement such as carbon fiber reinforcement. In preferred embodiments the facesheets are over layered with a decorative film. The properties of these composites make them attractive materials of construction aircraft and spacecraft.
NASA Astrophysics Data System (ADS)
Samanta, Ashis Kumar; Bagchi, Arindam
2017-06-01
Treatment with sodium stannate followed by treatment with boric acid imparts jute fabric wash fast fire resistance property as indicated by its Limiting Oxygen Index (LOI) value and 45° inclined flammability test results. The treatment was carried out by impregnation of sodium stannate followed by impregnation with an aqueous solution of boric acid and drying. Application of sodium stannate (20%) and boric acid (20%) treatment on jute fabric showed balanced flame retardancy property (LOI value 34) with some loss in fabric tenacity (loss of tenacity is 14.5%). Treated fabric retained good fire retardant property after three consecutive washing. Treated fabric also possessed good rot resistance property as indicated by soil burial test and strength retention after 21 days soil burial was found to be 65%. It is found that of sodium stannate and boric acid combination by double bath process form a synergistic durable fire-retardant as well as rot resistant when impregnated on jute material, which is considerably greater than the use of either sodium stannate or boric acid alone. TGA, FTIR and SEM analysis are also reported to support the results and reaction mechanism.
Faster growth in warmer winters for large trees in a Mediterranean-climate ecosystem
Seth W. Bigelow; Michael J. Papaik; Caroline Caum; Malcolm P. North
2014-01-01
Large trees (>76 cm breast-height diameter) are vital components of Sierra Nevada/Cascades mixed-conifer ecosystems because of their fire resistance, ability to sequester large amounts of carbon, and role as preferred habitat for sensitive species such as the California spotted owl. To investigate the likely performance of large trees in a rapidly changing...
Reduced firing rates of high threshold motor units in response to eccentric overload.
Balshaw, Tom G; Pahar, Madhu; Chesham, Ross; Macgregor, Lewis J; Hunter, Angus M
2017-01-01
Acute responses of motor units were investigated during submaximal voluntary isometric tasks following eccentric overload (EO) and constant load (CL) knee extension resistance exercise. Ten healthy resistance-trained participants performed four experimental test sessions separated by 5 days over a 20 day period. Two sessions involved constant load and the other two used eccentric overload. EO and CL used both sessions for different target knee eccentric extension phases; one at 2 sec and the other at 4 sec. Maximal voluntary contractions (MVC) and isometric trapezoid efforts for 10 sec at 70% MVC were completed before and after each intervention and decomposed electromyography was used to measure motor unit firing rate. The firing rate of later recruited, high-threshold motor units declined following the 2-sec EO but was maintained following 2sec CL (P < 0.05), whereas MUFR for all motor units were maintained for both loading types following 4-sec extension phases. MVC and rate of force development where maintained following both EO and CL and 2 and 4 sec phases. This study demonstrates a slower firing rate of high-threshold motor units following fast eccentric overload while MVC was maintained. This suggests that there was a neuromuscular stimulus without cost to the force-generating capacity of the knee extensors. © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.
Numerical Simulation of Thermal Performance of Glass-Fibre-Reinforced Polymer
NASA Astrophysics Data System (ADS)
Zhao, Yuchao; Jiang, Xu; Zhang, Qilin; Wang, Qi
2017-10-01
Glass-Fibre-Reinforced Polymer (GFRP), as a developing construction material, has a rapidly increasing application in civil engineering especially bridge engineering area these years, mainly used as decorating materials and reinforcing bars for now. Compared with traditional construction material, these kinds of composite material have obvious advantages such as high strength, low density, resistance to corrosion and ease of processing. There are different processing methods to form members, such as pultrusion and resin transfer moulding (RTM) methods, which process into desired shape directly through raw material; meanwhile, GFRP, as a polymer composite, possesses several particular physical and mechanical properties, and the thermal property is one of them. The matrix material, polymer, performs special after heated and endue these composite material a potential hot processing property, but also a poor fire resistance. This paper focuses on thermal performance of GFRP as panels and corresponding researches are conducted. First, dynamic thermomechanical analysis (DMA) experiment is conducted to obtain the glass transition temperature (Tg) of the object GFRP, and the curve of bending elastic modulus with temperature is calculated according to the experimental data. Then compute and estimate the values of other various thermal parameters through DMA experiment and other literatures, and conduct numerical simulation under two condition respectively: (1) the heat transfer process of GFRP panel in which the panel would be heated directly on the surface above Tg, and the hot processing under this temperature field; (2) physical and mechanical performance of GFRP panel under fire condition. Condition (1) is mainly used to guide the development of high temperature processing equipment, and condition (2) indicates that GFRP’s performance under fire is unsatisfactory, measures must be taken when being adopted. Since composite materials’ properties differ from each other and their high temperature parameters can’t be obtained through common methods, some parameters are estimated, the simulation is to guide the actual high temperature experiment, and the parameters will also be adjusted by then.
Production of durable expanded perlite microspheres in a Vertical Electrical Furnace
NASA Astrophysics Data System (ADS)
Panagiotis, M.; Angelopoulos, P.; Taxiarchou, M.; Paspaliaris, I.
2016-04-01
Expanded perlite constitutes one of the most competitive insulating materials that is widely used in construction and manufacturing industry due to its unique properties combination; it is white, natural, lightweight, chemically inert, and exhibits superior insulating properties (thermal and acoustic) and fire resistance. Conventionally, perlite expansion is performed in vertical gas-fired furnaces; the conventional perlite expansion process has certain disadvantages which affect expanded products quality, thus limiting their performance and range of applications. In order to overcome the drawbacks of the conventional expansion technique, a new perlite expansion process has been designed based on a vertical electrical furnace (VEF). In the current study, fine perlite samples (-150 μm) from Milos Island, Greece, were expansed in the novel VEF and a conventional gas-fired furnace with the aim to evaluate and compare the main physical properties of the expanded products. The novel expanded perlite particles were characterised by superior properties, namely increased compression strength, competitive water and oil absorption capability, size homogeneity, spherical shape and decreased surface porosity in comparison to conventionally expanded samples.
Si, Yang; Wang, Xueqin; Dou, Lvye; Yu, Jianyong; Ding, Bin
2018-04-01
Ultralight aerogels that are both highly resilient and compressible have been fabricated from various materials including polymer, carbon, and metal. However, it has remained a great challenge to realize high elasticity in aerogels solely based on ceramic components. We report a scalable strategy to create superelastic lamellar-structured ceramic nanofibrous aerogels (CNFAs) by combining SiO 2 nanofibers with aluminoborosilicate matrices. This approach causes the random-deposited SiO 2 nanofibers to assemble into elastic ceramic aerogels with tunable densities and desired shapes on a large scale. The resulting CNFAs exhibit the integrated properties of flyweight densities of >0.15 mg cm -3 , rapid recovery from 80% strain, zero Poisson's ratio, and temperature-invariant superelasticity to 1100°C. The integral ceramic nature also provided the CNFAs with robust fire resistance and thermal insulation performance. The successful synthesis of these fascinating materials may provide new insights into the development of ceramics in a lightweight, resilient, and structurally adaptive form.
Wang, Xueqin; Dou, Lvye; Yu, Jianyong
2018-01-01
Ultralight aerogels that are both highly resilient and compressible have been fabricated from various materials including polymer, carbon, and metal. However, it has remained a great challenge to realize high elasticity in aerogels solely based on ceramic components. We report a scalable strategy to create superelastic lamellar-structured ceramic nanofibrous aerogels (CNFAs) by combining SiO2 nanofibers with aluminoborosilicate matrices. This approach causes the random-deposited SiO2 nanofibers to assemble into elastic ceramic aerogels with tunable densities and desired shapes on a large scale. The resulting CNFAs exhibit the integrated properties of flyweight densities of >0.15 mg cm−3, rapid recovery from 80% strain, zero Poisson’s ratio, and temperature-invariant superelasticity to 1100°C. The integral ceramic nature also provided the CNFAs with robust fire resistance and thermal insulation performance. The successful synthesis of these fascinating materials may provide new insights into the development of ceramics in a lightweight, resilient, and structurally adaptive form. PMID:29719867
30 CFR 7.64 - Technical requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... produce the required firing current is attained. (d) Firing switch. The switch used to initiate the... current is available to the blasting circuit. (e) Firing line terminals. The terminals used to connect the blasting circuit to the blasting unit shall— (1) Provide a secure, low-resistance connection to the...
30 CFR 7.64 - Technical requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... produce the required firing current is attained. (d) Firing switch. The switch used to initiate the... current is available to the blasting circuit. (e) Firing line terminals. The terminals used to connect the blasting circuit to the blasting unit shall— (1) Provide a secure, low-resistance connection to the...
Remote multi-function fire alarm system based on internet of things
NASA Astrophysics Data System (ADS)
Wang, Lihui; Zhao, Shuai; Huang, Jianqing; Ji, Jianyu
2018-05-01
This project uses MCU STC15W408AS (stable, energy saving, high speed), temperature sensor DS18B20 (cheap, high efficiency, stable), MQ2 resistance type semiconductor smog sensor (high stability, fast response and economy) and NRF24L01 wireless transmitting and receiving module (energy saving, small volume, reliable) as the main body to achieve concentration temperature data presentation, intelligent voice alarming and short distance wireless transmission. The whole system is safe, reliable, cheap, quick reaction and good performance. This project uses the MCU STM32F103RCT6 as the main control chip, and use WIFI module ESP8266, wireless module NRF24L01 to make the gateway. Users can remotely check and control the related devices in real-time on smartphones or computers. We can also realize the functions of intelligent fire monitoring, remote fire extinguishing, cloud data storage through the third party server Big IOT.
Hood, Sharon M; Baker, Stephen; Sala, Anna
2016-10-01
Fire frequency in low-elevation coniferous forests in western North America has greatly declined since the late 1800s. In many areas, this has increased tree density and the proportion of shade-tolerant species, reduced resource availability, and increased forest susceptibility to forest insect pests and high-severity wildfire. In response, treatments are often implemented with the goal of increasing ecosystem resilience by increasing resistance to disturbance. We capitalized on an existing replicated study of fire and stand density treatments in a ponderosa pine (Pinus ponderosa)-Douglas-fir (Pseudotsuga menziesii) forest in western Montana, USA, that experienced a naturally occurring mountain pine beetle (MPB; Dendroctonus ponderosae) outbreak 5 yr after implementation of fuels treatments. We explored whether treatment effects on tree-level defense and stand structure affected resistance to MPB. Mortality from MPB was highest in the denser, untreated control and burn-only treatments, with approximately 50% and 39%, respectively, of ponderosa pine killed during the outbreak, compared to almost no mortality in the thin-only and thin-burn treatments. Thinning treatments, with or without fire, dramatically increased tree growth and resin ducts relative to control and burn-only treatments. Prescribed burning did not increase resin ducts but did cause changes in resin chemistry that may have affected MPB communication and lowered attack success. While ponderosa pine remained dominant in the thin and thin-burn treatments after the outbreak, the high pine mortality in the control and burn-only treatment caused a shift in species dominance to Douglas-fir. The high Douglas-fir component in the control and burn-only treatments due to 20th century fire exclusion, coupled with high pine mortality from MPB, has likely reduced resilience of this forest beyond the ability to return to a ponderosa pine-dominated system in the absence of further fire or mechanical treatment. Our results show treatments designed to increase resistance to high-severity fire in ponderosa pine-dominated forests in the Northern Rockies can also increase resistance to MPB, even during an outbreak. This study suggests that fuel and restoration treatments in fire-dependent ponderosa pine forests that reduce tree density increase ecosystem resilience in the short term, while the reintroduction of fire is important for long-term resilience. © 2016 by the Ecological Society of America.
Influence of the silicon carbide deposit on the thermal resistance of fire protection
NASA Astrophysics Data System (ADS)
Kim, K. A.; Lemeshev, D. O.
2018-04-01
The ceramics samples with structure of SiC-Al2O3-Fireclay having good thermal resistance were received. As materials were used: black α-SiC F-120, corundum α-Al2O3 F-1000 and Kudinovsky fire-clay. As a temporary technological bundle used polyvinyl alcohol (PVA). Thermal stability was determined by method of heat changes.
Fire resistant resilient foams. [for seat cushions
NASA Technical Reports Server (NTRS)
Gagliani, J.
1976-01-01
Primary program objectives were the formulation, screening, optimization and characterization of open-cell, fire resistant, low-smoke emitting, thermally stable, resilient polyimide foams suitable for seat cushions in commercial aircraft and spacecraft. Secondary program objectives were to obtain maximum improvement of the tension, elongation and tear characteristics of the foams, while maintaining the resiliency, thermal stability, low smoke emission and other desirable attributes of these materials.
NASA Technical Reports Server (NTRS)
1984-01-01
Solimide manufactured by Imi-Tech Corporation, is a lightweight fire resistant material produced under a manufacturing process that allows it to be uniformly foamed. Can be produced in a variety of densities and structural configurations and remains resilient under exposure to temperatures ranging from minus 300 to plus 500 degrees Fahrenheit. Is resistant to open flame and generates virtually no smoke or toxic by-products. Used in aircraft for its superior damping characteristics, lighter weight and fire barrier properties, it's also applicable to ships and surface transportation systems such as transit cars, trains, buses and automobiles.
Potential benefits of a ceramic thermal barrier coating on large power generation gas turbine
NASA Technical Reports Server (NTRS)
Clark, J. S.; Nainiger, J. J.
1977-01-01
Thermal barrier coating design option offers benefit in terms of reduced electricity costs when used in utility gas turbines. Options considered include: increased firing temperature, increased component life, reduced cooling air requirements, and increased corrosion resistance (resulting in increased tolerance for dirty fuels). Performance and cost data were obtained. Simple, recuperated and combined cycle applications were considered, and distillate and residual fuels were assumed. The results indicate that thermal barrier coatings could produce large electricity cost savings if these coatings permit turbine operation with residual fuels at distillate-rated firing temperatures. The results also show that increased turbine inlet temperature can result in substantial savings in fuel and capital costs.
46 CFR 116.423 - Furniture and furnishings.
Code of Federal Regulations, 2011 CFR
2011-10-01
... ARRANGEMENT Fire Protection § 116.423 Furniture and furnishings. (a) For the purpose of this subpart, rooms containing “fire resistant furnishings” are considered to be those in which: (1) Furniture such as chairs, sofas, and similar items are tested and meet the requirements in UL 1056 “Fire Test of Upholstered...
46 CFR 116.423 - Furniture and furnishings.
Code of Federal Regulations, 2010 CFR
2010-10-01
... ARRANGEMENT Fire Protection § 116.423 Furniture and furnishings. (a) For the purpose of this subpart, rooms containing “fire resistant furnishings” are considered to be those in which: (1) Furniture such as chairs, sofas, and similar items are tested and meet the requirements in UL 1056 “Fire Test of Upholstered...
Engineering and Development Program Plan, Aircraft Cabin Fire Safety.
1980-06-01
relative to a postcrash fuel fire, or whether advanced materials provide a significant safety benefit in comparison to inservice materials. if either...have always been controlled by early detection and prompt extinguishment action by effectively trained crew members. In addition, the fire resistant...occupants. g. Develop a computer fire test data bank with broad user availability for inservice and candidate cabin interior materials. h. Identify
Eric J. Gustafson; Patrick A. Zollner; Brian R. Sturtevant; S. He Hong; David J. Mladenoff
2004-01-01
We used the LANDIS disturbance and succession model to study the effects of six alternative vegetation management scenarios on forest succession and the subsequent risk of canopy fire on a 2791 km2 landscape in northern Wisconsin, USA. The study area is a mix of fire-prone and fire-resistant land types. The alternatives vary the spatial...
New fire-fighting water bucket releases its water for a demonstration
NASA Technical Reports Server (NTRS)
2000-01-01
A NASA helicopter releases 324 gallons of water onto a building in a simulated fire control demonstration. The high-impact- resistant flexible plastic bucket will be used for fire protection on property and buildings at Kennedy Space Center. Known as the 'Bambi' bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.
Aćimović, Srđan G.; Zeng, Quan; McGhee, Gayle C.; Sundin, George W.; Wise, John C.
2015-01-01
Management of fire blight is complicated by limitations on use of antibiotics in agriculture, antibiotic resistance development, and limited efficacy of alternative control agents. Even though successful in control, preventive antibiotic sprays also affect non-target bacteria, aiding the selection for resistance which could ultimately be transferred to the pathogen Erwinia amylovora. Trunk injection is a target-precise pesticide delivery method that utilizes tree xylem to distribute injected compounds. Trunk injection could decrease antibiotic usage in the open environment and increase the effectiveness of compounds in fire blight control. In field experiments, after 1–2 apple tree injections of either streptomycin, potassium phosphites (PH), or acibenzolar-S-methyl (ASM), significant reduction of blossom and shoot blight symptoms was observed compared to water injected control trees. Overall disease suppression with streptomycin was lower than typically observed following spray applications to flowers. Trunk injection of oxytetracycline resulted in excellent control of shoot blight severity, suggesting that injection is a superior delivery method for this antibiotic. Injection of both ASM and PH resulted in the significant induction of PR-1, PR-2, and PR-8 protein genes in apple leaves indicating induction of systemic acquired resistance (SAR) under field conditions. The time separating SAR induction and fire blight symptom suppression indicated that various defensive compounds within the SAR response were synthesized and accumulated in the canopy. ASM and PH suppressed fire blight even after cessation of induced gene expression. With the development of injectable formulations and optimization of doses and injection schedules, the injection of protective compounds could serve as an effective option for fire blight control. PMID:25717330
24 CFR 3280.206 - Fireblocking.
Code of Federal Regulations, 2011 CFR
2011-04-01
... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.206 Fireblocking. (a... materials: (1) Minimum one inch nominal lumber, 5/16 inch thick gypsum board, or equivalent fire resistive...
24 CFR 3280.206 - Fireblocking.
Code of Federal Regulations, 2012 CFR
2012-04-01
... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.206 Fireblocking. (a... materials: (1) Minimum one inch nominal lumber, 5/16 inch thick gypsum board, or equivalent fire resistive...
24 CFR 3280.206 - Fireblocking.
Code of Federal Regulations, 2014 CFR
2014-04-01
... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.206 Fireblocking. (a... materials: (1) Minimum one inch nominal lumber, 5/16 inch thick gypsum board, or equivalent fire resistive...
24 CFR 3280.206 - Fireblocking.
Code of Federal Regulations, 2010 CFR
2010-04-01
... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.206 Fireblocking. (a... materials: (1) Minimum one inch nominal lumber, 5/16 inch thick gypsum board, or equivalent fire resistive...
24 CFR 3280.206 - Fireblocking.
Code of Federal Regulations, 2013 CFR
2013-04-01
... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.206 Fireblocking. (a... materials: (1) Minimum one inch nominal lumber, 5/16 inch thick gypsum board, or equivalent fire resistive...
Franzen, Delwen L; Gleiss, Sarah A; Berger, Christina; Kümpfbeck, Franziska S; Ammer, Julian J; Felmy, Felix
2015-01-15
Passive and active membrane properties determine the voltage responses of neurons. Within the auditory brain stem, refinements in these intrinsic properties during late postnatal development usually generate short integration times and precise action-potential generation. This developmentally acquired temporal precision is crucial for auditory signal processing. How the interactions of these intrinsic properties develop in concert to enable auditory neurons to transfer information with high temporal precision has not yet been elucidated in detail. Here, we show how the developmental interaction of intrinsic membrane parameters generates high firing precision. We performed in vitro recordings from neurons of postnatal days 9-28 in the ventral nucleus of the lateral lemniscus of Mongolian gerbils, an auditory brain stem structure that converts excitatory to inhibitory information with high temporal precision. During this developmental period, the input resistance and capacitance decrease, and action potentials acquire faster kinetics and enhanced precision. Depending on the stimulation time course, the input resistance and capacitance contribute differentially to action-potential thresholds. The decrease in input resistance, however, is sufficient to explain the enhanced action-potential precision. Alterations in passive membrane properties also interact with a developmental change in potassium currents to generate the emergence of the mature firing pattern, characteristic of coincidence-detector neurons. Cholinergic receptor-mediated depolarizations further modulate this intrinsic excitability profile by eliciting changes in the threshold and firing pattern, irrespective of the developmental stage. Thus our findings reveal how intrinsic membrane properties interact developmentally to promote temporally precise information processing. Copyright © 2015 the American Physiological Society.
Chambers, Jeanne C.; Miller, Richard F.; Board, David I.; Pyke, David A.; Roundy, Bruce A.; Grace, James B.; Schupp, Eugene W.; Tausch, Robin J.
2014-01-01
In sagebrush ecosystems invasion of annual exotics and expansion of piñon (Pinus monophylla Torr. and Frem.) and juniper (Juniperus occidentalis Hook., J. osteosperma [Torr.] Little) are altering fire regimes and resulting in large-scale ecosystem transformations. Management treatments aim to increase resilience to disturbance and enhance resistance to invasive species by reducing woody fuels and increasing native perennial herbaceous species. We used Sagebrush Steppe Treatment Evaluation Project data to test predictions on effects of fire vs. mechanical treatments on resilience and resistance for three site types exhibiting cheatgrass (Bromus tectorum L.) invasion and/or piñon and juniper expansion: 1) warm and dry Wyoming big sagebrush (WY shrub); 2) warm and moist Wyoming big sagebrush (WY PJ); and 3) cool and moist mountain big sagebrush (Mtn PJ). Warm and dry (mesic/aridic) WY shrub sites had lower resilience to fire (less shrub recruitment and native perennial herbaceous response) than cooler and moister (frigid/xeric) WY PJ and Mtn PJ sites. Warm (mesic) WY Shrub and WY PJ sites had lower resistance to annual exotics than cool (frigid to cool frigid) Mtn PJ sites. In WY shrub, fire and sagebrush mowing had similar effects on shrub cover and, thus, on perennial native herbaceous and exotic cover. In WY PJ and Mtn PJ, effects were greater for fire than cut-and-leave treatments and with high tree cover in general because most woody vegetation was removed increasing resources for other functional groups. In WY shrub, about 20% pretreatment perennial native herb cover was necessary to prevent increases in exotics after treatment. Cooler and moister WY PJ and especially Mtn PJ were more resistant to annual exotics, but perennial native herb cover was still required for site recovery. We use our results to develop state and transition models that illustrate how resilience and resistance influence vegetation dynamics and management options.
NASA Technical Reports Server (NTRS)
Hooker, Matthew W.
1996-01-01
An evaluation of four firing profiles was performed to determine the optimum processing conditions for producing high-T(sub c) Bi-Pb-Sr-Ca-Cu-O thick films on yttria-stabilized zirconia substrates. Using these four profiles, the effects of sintering temperatures of 830-850 C and soak times of 0.5 to 12 hours were examined. In this study, T-c, zero values of 100 K were obtained using a firing profile in which the films were sintered for 1.5 to 2 hours at 840 to 845 C and then quenched to room temperature. X-ray diffraction analyses of these specimens confirmed the presence of the high-T(sub c) phase. Films which were similarly fired and furnace cooled from the peak processing temperature exhibited a two-step superconductive transition to zero resistance, with T-c,zero values ranging from 85 to 92 K. The other firing profiles evaluated in this investigation yielded specimens which either exhibited critical transition temperatures below 90 K or did not exhibit a superconductive transition above 77 K.
Smoldering and Flame Resistant Textiles via Conformal Barrier Formation.
Zammarano, Mauro; Cazzetta, Valeria; Nazaré, Shonali; Shields, J Randy; Kim, Yeon Seok; Hoffman, Kathleen M; Maffezzoli, Alfonso; Davis, Rick
2016-12-07
A durable and flexible silicone-based backcoating (halogen free) is applied to the backside of an otherwise smoldering-prone and flammable fabric. When exposed to fire, cyclic siloxanes (produced by thermal decomposition of the backcoating) diffuse through the fabric in the gas phase. The following oxidation of the cyclic siloxanes forms a highly conformal and thermally stable coating that fully embeds all individual fibers and shields them from heat and oxidation. As a result, the combustion of the fabric is prevented. This is a novel fire retardant mechanism that discloses a powerful approach towards textiles and multifunctional flexible materials with combined smoldering/flaming ignition resistance and fire-barrier properties.
Solution of Fire Protection in Historic Buildings
NASA Astrophysics Data System (ADS)
Iringová, Agnes; Idunk, Róbert
2016-12-01
The paper introduces optimization of the functional use of renovated spaces in historic buildings in terms of fire risk. It brings assessment of fire protection in the folk house Habánsky Dvor, situated in the village of Veľké Leváre, whose function was changed into the museum. It goes into static analysis of existing load-bearing structures and assessment of their fire resistance according to Eurocodes.
Aircraft Hangar Fire Suppression System Evaluation-Intermediate- Scale Studies
1999-12-23
aqueous film forming foam ( AFFF ) extinguishing systems [1]. The overhead AFFF system typically consists of standard closed head sprinklers that...of Water Spray on Fire-Fighting Foam ," Fire Journal, 63 (6), November 1969. 5. MIL-F-24385F, "Fire Extinguishing Agent, Aqueous Film Forming Foam ...extinguishing capability of the foam and the ability of the blanket to resist burnback. When AFFF is applied over a flammable liquid spill
Production rates for crews using hand tools on firelines
Lisa Haven; T. Parkin Hunter; Theodore G. Storey
1982-01-01
Reported rates at which hand crews construct firelines can vary widely because of differences in fuels, fire and measurement conditions, and fuel resistance-to-control classification schemes. Real-time fire dispatching and fire simulation planning models, however, require accurate estimates of hand crew productivity. Errors in estimating rate of fireline production...
30 CFR 57.4531 - Surface flammable or combustible liquid storage buildings or rooms.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Installation/construction/maintenance § 57.4531 Surface... fire resistance rating of at least one hour; or (2) Equipped with an automatic fire supression system...
New fire-fighting water bucket is lifted by helicopter
NASA Technical Reports Server (NTRS)
2000-01-01
A NASA helicopter lifts a high-impact-resistant flexible plastic bucket that will be used for fire protection on property and buildings at Kennedy Space Center. Known as the 'Bambi' bucket, the 324-gallon container will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.
49 CFR 178.358-2 - Materials of construction and other requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Materials of construction and other requirements. (a) Phenolic foam insulation must be fire resistant and... equivalent. (d) Fire-retardant (intumescent) paint must be applied to any wood blocking which is located at... provide pressure relief during the insulation foaming and in the event of a fire. These holes, which must...
A new approach to characterize the effect of fabric deformation on thermal protective performance
NASA Astrophysics Data System (ADS)
Li, Jun; Li, Xiaohui; Lu, Yehu; Wang, Yunyi
2012-04-01
It is very important to evaluate thermal protective performance (TPP) in laboratory-simulated fire scenes as accurately as possible. For this paper, to thoroughly understand the effect of fabric deformation on basic physical properties and TPP of flame-retardant fabrics exposed to flash fire, a new modified TPP testing apparatus was developed. Different extensions were employed to simulate the various extensions displayed during different body motions. The tests were also carried out with different air gaps. The results showed a significant decrease in air permeability after deformation. However, the change of thickness was slight. The fabric deformation had a complicated effect on thermal protection with different air gaps. The change of TPP depended on the balance between the surface contact area and the thermal insulation. The newly developed testing apparatus could be well employed to evaluate the effect of deformation on TPP of flame-resistant fabrics.
High Temperature Behavior of Cr3C2-NiCr Coatings in the Actual Coal-Fired Boiler Environment
NASA Astrophysics Data System (ADS)
Bhatia, Rakesh; Sidhu, Hazoor Singh; Sidhu, Buta Singh
2015-03-01
Erosion-corrosion is a serious problem observed in steam-powered electricity generation plants, and industrial waste incinerators. In the present study, four compositions of Cr3C2-(Ni-20Cr) alloy coating powder were deposited by high-velocity oxy-fuel spray technique on T-91 boiler tube steel. The cyclic studies were performed in a coal-fired boiler at 1123 K ± 10 K (850 °C ± 10 °C). X-ray diffraction, scanning electron microscopy/energy dispersive X-ray analysis and elemental mapping analysis techniques were used to analyze the corrosion products. All the coatings deposited on T-91 boiler tube steel imparted hot corrosion resistance. The 65 pctCr3C2 -35 pct (Ni-20Cr)-coated T-91 steel sample performed better than all other coated samples in the given environment.
Development of fire resistant, nontoxic aircraft interior materials
NASA Technical Reports Server (NTRS)
Haley, G.; Silverman, B.; Tajima, Y.
1976-01-01
All available newly developed nonmetallic polymers were examined for possible usage in developing fire resistant, nontoxic nonmetallic parts or assemblies for aircraft interiors. Specifically, feasibility for the development of clear films for new decorative laminates, compression moldings, injection molded parts, thermoformed plastic parts, and flexible foams were given primary considerations. Preliminary data on the flame resistant characteristics of the materials were obtained. Preliminary toxicity data were generated from samples of materials submitted from the contractor. Preliminary data on the physical characteristics of various thermoplastic materials to be considered for either compression molded, injection molded, or thermoformed parts were obtained.
Fire resistant PV shingle assembly
Lenox, Carl J.
2012-10-02
A fire resistant PV shingle assembly includes a PV assembly, including PV body, a fire shield and a connection member connecting the fire shield below the PV body, and a support and inter-engagement assembly. The support and inter-engagement assembly is mounted to the PV assembly and comprises a vertical support element, supporting the PV assembly above a support surface, an upper interlock element, positioned towards the upper PV edge, and a lower interlock element, positioned towards the lower PV edge. The upper interlock element of one PV shingle assembly is inter-engageable with the lower interlock element of an adjacent PV shingle assembly. In some embodiments the PV shingle assembly may comprise a ventilation path below the PV body. The PV body may be slidably mounted to the connection member to facilitate removal of the PV body.
Numerical prediction of fire resistance of RC beams
NASA Astrophysics Data System (ADS)
Serega, Szymon; Wosatko, Adam
2018-01-01
Fire resistance of different structural members is an important issue of their strength and durability. A simple but effective tool to investigate multi-span reinforced concrete beams exposed to fire is discussed in the paper. Assumptions and simplifications of the theory as well as numerical aspects are briefly reviewed. Two steps of nonlinear finite element analysis and two levels of observation are distinguished. The first step is the solution of transient heat transfer problem in representative two-dimensional reinforced concrete cross-section of a beam. The second part is a nonlinear mechanical analysis of the whole beam. All spans are uniformly loaded, but an additional time-dependent thermal load due to fire acts on selected ones. Global changes of curvature and bending moment functions induce deterioration of the stiffness. Benchmarks are shown to confirm the correctness of the model.
Buscardo, Erika; Rodríguez-Echeverría, Susana; Martín, María P; De Angelis, Paolo; Pereira, João Santos; Freitas, Helena
2010-08-01
Ectomycorrhizal (ECM) fungi, in particular their spores and other resistant propagules, play an important role in secondary succession processes that facilitate regeneration after disturbance events. In this study, the effects of high and low wildfire frequencies (respectively short and long fire return intervals) on the resistant propagules communities (RPCs) of a Mediterranean open pine forest were compared. Soil samples were collected in four mountain sites with different fire return intervals and used to test ectomycorrhiza development in two hosts, Pinus pinaster and Quercus suber. RPCs were characterized by direct sequencing of fungal internal transcribed spacer (ITS) regions from individual ECM root tips. Eighteen ECM species were detected in the bioassay. The most frequently found fungi were Cenococcum geophilum, Inocybe jacobi, Thelephora terrestris, Tomentella ellisii on both hosts and Rhizopogon luteolus and R. roseolus on maritime pine. A short fire return interval reduced the species richness of the ECM community found on Q. suber, promoted species like R. roseolus and reduced the abundance of other species (e.g. R. luteolus). The abundance of I. jacobi was positively affected by long fire return interval, but decreased significantly with recurrent fires. These results indicate that changes in fire frequency can alter the structure, composition and diversity of ECM communities, which could compromise the resilience of the ecosystem in highly disturbed areas. Copyright © 2010 The British Mycological Society. Published by Elsevier Ltd. All rights reserved.
Chen, Lei; Cai, Hui; Xu, Guo-fu; Fang, Chang-yun
2006-06-01
To determine the effect of porcelain firing cycle on microstructure of 4 metal ceramic alloys, and to analyze the changes of their corrosion resistance in the artificial saliva. We simulated the process of firing and repolishing when fabricating porcelain-fused-to-metal restoration in clinic,and then observed the microstructures of Ni-Cr, Ni-Cr-Ti, Co-Cr alloys and high gold alloy by field emission scanning electron microscopy and energy dispersive spectroscopy. The electrochemical corrosion behavior of alloys in artificial saliva was analyzed by polarization curves and corrview 2 corrosion analysis software. The data of self-corrosion potential and transpassive potential were obtained and analyzed. After the porcelain firing cycle, the surface composition changed slightly, and the morphological in the 3 predominate base metal alloys also changed. The self-corrosion potential turned to more negative, and the transpassive potential declined. The procedure of porcelain firing cycle can affect the surface microstructure and increase the corrosion of 4 metal-ceramic alloys.
Geophysical survey for groundwater potential investigation in peat land area, Riau, Indonesia
NASA Astrophysics Data System (ADS)
Islami, N.; Irianti, M.; Azhar; Nor, M.; Fakhrudin
2018-04-01
Tropical forests, especially peat lands, are particularly vulnerable to forest fires. Fires are the most common disasters in peat lands in the dry season, especially in Riau Province, Indonesia. In the process of extinguishing the peat fire, several substantial problems arise to stop peat fires during this period. This study aims to determine the possibility of using ground water as a source of water to anticipate the early mitigation of peat land fires disaster. The geoelectrical resistivity surveys were used to predict the subsurface geological data including peat thickness and depth of aquifers. The geometry of peat lands was determined using geostatistics based on geoelectrical resistivity interpretation data. Peat Land thickness varies up to 4 m in the north and is thinner to the south. A shallower and deeper aquifer is available at a depth of 13 m to 18 m and 70 m to 90 m respectively. In general, the potential of groundwater in the shallow aquifer is predicted to be sufficient for peat land watering anytime.
Jeanne C. Chambers; David A. Pyke; Jeremy D. Maestas; Mike Pellant; Chad S. Boyd; Steven B. Campbell; Shawn Espinosa; Douglas W. Havlina; Kenneth E. Mayer; Amarina Wuenschel
2014-01-01
This Report provides a strategic approach for conservation of sagebrush ecosystems and Greater Sage- Grouse (sage-grouse) that focuses specifically on habitat threats caused by invasive annual grasses and altered fire regimes. It uses information on factors that influence (1) sagebrush ecosystem resilience to disturbance and resistance to invasive annual grasses and (2...
Polymer of phosphonylmethyl-2,4- and -2,6-diamino benzene and polyfunctional monomer
NASA Technical Reports Server (NTRS)
Mikroyannidis, J. A. (Inventor); Kourtides, D. A. (Inventor)
1986-01-01
A phosphonyl methyl benzene is prepared by nitration to produce a 2,4-dinitro phosphonyl methyl benzene, which is then reduced to a diamino compound. The diamino compound is then used to cure a polymerizable monomer. The diamino compound may be polymerized with polyfunctional epoxides to produce heat and fire resistant polymer structures for making flame and fire resistant polymer structures such as for aircraft secondary structures.
NASA Astrophysics Data System (ADS)
Yasir, Muhammad; Amir, Norlaili Binti; Ahmad, Faiz; Syahirah Rodzhan, N.
2017-08-01
This research is carried out in order to study the synergistic effect of aluminium trihydrate and basalt fibres on the properties of fire resistant intumescent coatings. Intumescent fire retardant coatings were developed using different flame retardants such as ammonium polyphosphate, expandable graphite, melamine and boric acid. These flame retardants were bound together with the help of epoxy binder along with curing agent. Furthermore, individual and combinations of aluminium trihydrate and basalt fibres was incorporated in the formulations to analyse mechanical and chemical properties of the coatings. Char expansion was observed using furnace test, thermogravimetric analysis was used to determine residual weight, X-Ray Diffraction was performed to investigate compounds present in the char, shear test was conducted to determine char strength and scanning electron microscopy analysis was performed to observe morphology of the burnt char. From the microscopic investigation it was concluded that the dense structure of the char increased the char integrity by adding basalt and aluminium trihydrate as fillers. X-Ray Diffraction results shows the presence boron phosphate, and boric acid which enhanced the thermal performance of the coating up to 800°C. From the Thermogravimetric analysis it was concluded that the residual weight of the char was increased up to 34.9 % for IC-B2A4 which enhanced thermal performance of intumescent coating.
Investigation on Low Firing Copper for Front Electrode of Si-Based Solar Cell Applications.
Chiang, Chen-Su; Wu, Yia-Ming; Lee, Wen-Hsi
2018-04-01
Solar cell is one of the most popular alternative energies. The aim of this study is to construct an ohmic contact between front electrode and Si-based solar cell by a Newly-invented low-cost paste and low temperature sintering process. The core-shell of CucoreAgshell powders were prepared for making high solid content paste, then screen printing the fine line on laser-opening H-pattern silicon substrate and applying firing process. Because the silver coverage is more than 95% and silver nanoparticles start to melt at 200 °C. The shell of nanoparticles of silver not only is used to prevent copper from oxidized, but also connected core Cu particles for enhancing the conductivity of CucoreAgshell. TEM, EDS, SEM were used to examine the microstructure of CucoreAgshell. Fourpoint probe and transmission line model were employed to analyze the sheet resistance and the specific contact resistance. The lowest specific contact resistivity is 0.005 Ωcm2, sheet resistance is 0.0138 Ω/ and the lowest resistivity of front electrode measured is 2.65 × 10-5 Ωcm when CucoreAgshell paste with 94 wt% solid content was fired at 550 °C.
New Trends in Reaction and Resistance to Fire of Fire-retardant Epoxies
Gérard, Caroline; Fontaine, Gaëlle; Bourbigot, Serge
2010-01-01
This paper focuses on current trends in the flame retardancy of epoxy-based thermosets. This review examines the incorporation of additives in these polymers, including synergism effects. Reactive flame-retardants—which are incorporated in the polymer backbone—are reported and the use of fire-retardant epoxy coatings for materials protection is also considered. PMID:28883337
29 CFR 1910.36 - Design and construction requirements for exit routes.
Code of Federal Regulations, 2014 CFR
2014-07-01
... that remains closed or automatically closes in an emergency upon the sounding of a fire alarm or employee alarm system. Each fire door, including its frame and hardware, must be listed or approved by a... route must be a permanent part of the workplace. (2) An exit must be separated by fire resistant...
29 CFR 1910.36 - Design and construction requirements for exit routes.
Code of Federal Regulations, 2013 CFR
2013-07-01
... that remains closed or automatically closes in an emergency upon the sounding of a fire alarm or employee alarm system. Each fire door, including its frame and hardware, must be listed or approved by a... route must be a permanent part of the workplace. (2) An exit must be separated by fire resistant...
New fire-fighting water bucket is readied for a demonstration
NASA Technical Reports Server (NTRS)
2000-01-01
Workers attach a high-impact-resistant flexible plastic bucket to a NASA helicopter. Holding 324 gallons of water, it will be used for fire protection on property and buildings at Kennedy Space Center. Known as the 'Bambi' bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.
New fire-fighting water bucket is filled for demonstration
NASA Technical Reports Server (NTRS)
2000-01-01
- A NASA helicopter hovers over the water while a high-impact- resistant flexible plastic bucket fills. The 324-gallon container will be used for fire protection on property and buildings at Kennedy Space Center. Known as the 'Bambi' bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.
New fire-fighting water bucket is lifted from water for a demonstration
NASA Technical Reports Server (NTRS)
2000-01-01
A NASA helicopter lifts a high-impact-resistant flexible plastic bucket filled with water. The container will be used for fire protection on property and buildings at Kennedy Space Center.. Known as the 'Bambi' bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.
Extinguishment and Burnback Testing of Fire Fighting Agents
2005-09-26
resisting burnback for hydrocarbon fuel fires. Potential Aqueous Film Forming Foam ( AFFF ) replacements are required to exhibit an...simple, reliable test to evaluate the effectiveness of new foams being introduced into the market as potential Aqueous Film Forming Foam ( AFFF ...normal concentrations. Reference: Military Specification MIL-F-24385F, Fire Extinguishing Agent, Aqueous Film - Forming Foam
Mechanical properties of gypsum board at elevated temperatures
S.M. Cramer; O.M. Friday; R.H. White; G. Sriprutkiat
2003-01-01
Gypsum board is a common fire barrier used in house and general building construction. Recently, evaluation of the collapses of the World Trade Center Towers highlighted the potential role and failure of gypsum board in containing the fires and resisting damage. The use of gypsum board as primary fire protection of light-flame wood or steel construction is ubiquitous....
NASA Technical Reports Server (NTRS)
Schutter, K. J.; Duskin, F. E.
1982-01-01
Full-scale burn tests were conducted on thirteen different seat cushion configurations in a cabin fire simulator. The fire source used was a quartz lamp radiant energy panel with a propane pilot flame. During each test, data were recorded for cushion temperatures, radiant heat flux, rate of weight loss of test specimens, and cabin temperatures. When compared to existing passenger aircraft seat cushions, the test specimens incorporating a fire barrier and those fabricated from advance materials, using improved construction methods, exhibited significantly greater fire resistance.
An assessment of three different fire resistance tests for hydraulic fluids
NASA Astrophysics Data System (ADS)
Loftus, J. J.
1981-10-01
The Center for Fire Research at the National Bureau of Standards at the request of the Mine Safety and Health Administration (MSHA) and the Bureau of Mines made an evaluation or assessment of the three different flammability tests used by MSHA for measuring the fire resistance of hydraulic fluids intended for use in underground coal mining operations. The methods described in the Code of Federal Regulations Schedule 30, Part 35, consist of the following: an Autogenous Ignition Temperature Test, a Temperature-Pressure Spray Ignition Test, and a Test to Determine the Effect of Evaporation on the Flammability of Hydraulic Fluids. Recommendations for improvement of the three test procedures are provided.
Heat resistant protective hand covering
NASA Technical Reports Server (NTRS)
Tschirch, R. P.; Sidman, K. R.; Arons, I. J. (Inventor)
1984-01-01
A heat-resistant aromatic polyamide fiber is described. The outer surface of the shell is coated with a fire-resistant elastomer and liner. Generally conforming and secured to the shell and disposed inwardly of the shell, the liner is made of a felt fabric of temperature-resistant aromatic polymide fiber.
Lightweight, Fire-Resistant Graphite Composites
NASA Technical Reports Server (NTRS)
Kourtides, D. A.; Parker, J. A.; MING-TA-HSU
1986-01-01
Aircraft safety improved with interior paneling made of new laminate with good thermophysical properties. Featuring lightweight graphite composite, laminate more heat-and flame-resistant and produces much less smoke in fire than commonly used epoxy-resin-containing laminates. New laminate prepared without epoxy resin. Graphite unidirectional cloth preimpregnated with blend of vinyl polystyrylpyridine and bismaleimide (VPSP-BMI). Either of two types of VPSP-BMI blend used, depending on method of preparation of chemicals and technique used to fabricate panel.
Tropic Test of Bradley Fighting Vehicle Systems.
1985-05-23
CM-R AMSTE-SG-H AMSTE-PT-MT AMSTE-RM Aberden Proving Ground , MD 21005-5055 Commander U.S. Army Armament Research and Development Command ATTN: AMSMC...Requirements Appendix E -Vision Devices Appendix F - Grounding Circuit Resistance Appendix G - Human Factors Appendix H - Distribution List -" -"" 3...miles of operation o Time-on-Target Baseline Tests o Selected electrical and grounding circuit resistances o Armament Firing (25mm, 7.62mm and TOW) o Fire
Resistance after firing protected electric match
Montoya, Arsenio P.
1981-11-10
An electric match having electrical leads embedded in flame-producing compound is protected against an accidental resistance across the leads after firing by a length of heat-shrinkable tubing encircling the match body and having a skirt portion extending beyond the leads. The heat of the burning match and an adjacent thermal battery causes the tubing to fold over the end of the match body, covering the ends of the leads and protecting them from molten pieces of the battery.
Materials for fire resistant passenger seats in aircraft
NASA Technical Reports Server (NTRS)
Tesoro, G.; Moussa, A.
1980-01-01
The paper considers the selection of cushioning foam and upholstery fabric materials for aircraft passenger seats. Polyurethane, polychloroprene, polyimide, and polyphosphazene are the foam materials considered; and a variety of commercial and developmental fabrics (including wool, cotton, synthetics, and blends) are examined. Viable approaches to the design of fire-resistant seat assemblies are indicated. Results of an experimental laboratory study of fabrics and fabric/foam assemblies exposed to external point-source radiative heat flux are discussed.
Fire-resistant materials for aircraft passenger seat construction
NASA Technical Reports Server (NTRS)
Fewell, L. L.; Tesoro, G. C.; Moussa, A.; Kourtides, D. A.
1979-01-01
The thermal response characteristics of fabric and fabric-foam assemblies are described. The various aspects of the ignition behavior of contemporary aircraft passenger seat upholstery fabric materials relative to fabric materials made from thermally stable polymers are evaluated. The role of the polymeric foam backing on the thermal response of the fabric-foam assembly is also ascertained. The optimum utilization of improved fire-resistant fabric and foam materials in the construction of aircraft passenger seats is suggested.
Study to develop improved fire resistant aircraft passenger seat materials, phase 1
NASA Technical Reports Server (NTRS)
Trabold, E. L.
1977-01-01
The procurement and testing of a wide range of candidate materials is reported. Improved fire resistant nonmetallic materials were subjected to tests to evaluate their thermal characteristics, such as burn, smoke generation, heat release rate and toxicity. In addition, candidate materials were evaluated for mechanical, physical and aesthetic properties. Other properties considered included safety, comfort, durability and maintainability. The fiscal year 1977 and the projected 1980 cost data were obtained for aircraft seat materials.
Structural wood panels with improved fire resistance
NASA Technical Reports Server (NTRS)
Sawko, P. M. (Inventor)
1980-01-01
Structural wood paneling or other molded wood compositions consisting of finely divided wood chips, flour, or strands are bound together and hot pressed with a modified novolac resin which is the cured product of a prepolymer made from an aralkyl ether or halide with a phenol and a hardening agent such as hexamethylene tetramine. The fire resistance of these articles is further improved by incorporating in the binder certain inorganic fillers, especially a mixture of ammonium oxalate and ammonium phosphate.
1993-02-01
sintered in hydrogen furnace at very high temperatures . Multiple furnace firing occurs until the binders are removed and part density is achieved "* Process...and base Low temperature co-fired ceramic - Metallized for shielding and grounding - Low resistance thick-film metallization - High thermal resistance...ESPECIALLY LOW TEMPERATURE COFIRED CERAMIC CERAMICS HIGH THERMAL CONDUCTIVITY,MATCHED GaAS AND SILICON SUBSTRATE MATERIALS I I,1Z#A,17Mr1 J, TI
Franklin R. Ward; David V. Sandberg
1981-01-01
This publication presents tables on the behavior of fire and the resistance of fuels to control. The information is to be used with the publication, "Photo Series for Quantifying Forest Residues in the Ponderosa Pine Type, Ponderosa Pine and Associated Species Type, Lodgepole Pine Type" (Maxwell, Wayne G.; Ward, Franklin R. 1976. Gen. Tech. Rep. PNW-GTR-052....
Defense Infrastructure: DOD’s 2013 Facilities Corrosion Study Addressed Reporting Elements
2014-03-27
the coating system to metal structures helped prevent corrosion and provided resistance to fire . For the second element, to review a sampling of...noted, was to apply an epoxy coating system to metal structures to prevent corrosion and provide fire resistance. In 2006, DOD applied an epoxy... heat exchange Fuel distribution Plumbing Bridge Fuel storage Roof Building exterior—paint Generator Signage Compressor Hot water
Franklin R. Ward; David V. Sandberg
1981-01-01
This publication presents tables on the behavior of fire and the resistance: of fuels to control. The information is to be used with the photos in the publication, "Photo Series for Quantifying Forest Residues in the Sierra Mixed Conifer Type, Sierra True Fir Type" (Maxwell, Wayne G.; Ward, Franklin R. 1979. Gen. Tech. Rep. PNW-GTR-095. Portland, OR: U.S....
Preparation for foam composites. [using polybenzimidazole for fireproofing panels
NASA Technical Reports Server (NTRS)
Maximovich, M. G.
1974-01-01
Methods were developed for the fabrication of fire resistant panels utilizing polybenzimidazole (PBI) and Kerimid 601 resins along with glass, quartz, and Kevlar reinforcements. Stitched truss structure, both unfilled and filled with PBI foam, were successfully fabricated and tested. Second generation structures were then selected, fabricated, and tested, with a PBI/glass skin/PBI foam sandwich structure emerging as the optimum panel concept. Mechanical properties, smoke generation, and fire resistance were determined for the candidate panels.
Engineering an Undergarment for Flash/Flame Protection
2011-11-01
the event of a flash fire situation because the fabric could melt and stick to the Soldier’s skin causing more severe burn injury. Additionally, an...harm’s way which include fire fighters and police in their daily work. 1.1 Problem Statement The threat of burn injuries to Soldiers in combat due...to blasts, flash fires and secondary fires has resulted in the development of the Flame Resistant Army Combat Uniform, FR ACU. The FR ACUs provide
NASA Astrophysics Data System (ADS)
Shirko, A. V.; Kamlyuk, A. N.; Drobysh, A. S.; Spiglazov, A. V.
2017-05-01
A strength and stiffness comparative analysis has been made of a concrete slab reinforced with composite-reinforcement rods and a slab reinforced with steel rods. The stress-strain state has been assessed for both versions of reinforcement of the slab. The stress-strain state was determined under the action of only static load and with subsequent application of temperature fields, i.e., under standard-fire conditions. It has been shown that the fire resistance of the slab with a composite reinforcement turns out to be 1.6 higher as far as the bearing capacity is concerned, than the fire resistance of the slab with a steel reinforcement, although the initial deflection due to the action of only static load for the slab reinforced with composite rods exceeds six to seven times the deflection of the slab reinforced with steel rods.
Evaluation of a wearable physiological status monitor during simulated fire fighting activities.
Smith, Denise L; Haller, Jeannie M; Dolezal, Brett A; Cooper, Christopher B; Fehling, Patricia C
2014-01-01
A physiological status monitor (PSM) has been embedded in a fire-resistant shirt. The purpose of this research study was to examine the ability of the PSM-shirt to accurately detect heart rate (HR) and respiratory rate (RR) when worn under structural fire fighting personal protective equipment (PPE) during the performance of various activities relevant to fire fighting. Eleven healthy, college-aged men completed three activities (walking, searching/crawling, and ascending/descending stairs) that are routinely performed during fire fighting operations while wearing the PSM-shirt under structural fire fighting PPE. Heart rate and RR recorded by the PSM-shirt were compared to criterion values measured concurrently with an ECG and portable metabolic measurement system, respectively. For all activities combined (overall) and for each activity, small differences were found between the PSM-shirt and ECG (mean difference [95% CI]: overall: -0.4 beats/min [-0.8, -0.1]; treadmill: -0.4 beats/min [-0.7, -0.1]; search: -1.7 beats/min [-3.1, -.04]; stairs: 0.4 beats/min [0.04, 0.7]). Standard error of the estimate was 3.5 beats/min for all tasks combined and 1.9, 5.9, and 1.9 beats/min for the treadmill walk, search, and stair ascent/descent, respectively. Correlations between the PSM-shirt and criterion heart rates were high (r = 0.95 to r = 0.99). The mean difference between RR recorded by the PSM-shirt and criterion overall was 1.1 breaths/min (95% CI: -1.9 to -0.4). The standard error of the estimate for RR ranged from 4.2 breaths/min (treadmill) to 8.2 breaths/min (search), with an overall value of 6.2 breaths/min. These findings suggest that the PSM-shirt provides valid measures of HR and useful approximations of RR when worn during fire fighting duties.
Small-diameter timber alchemy: can utilization pay the way toward fire-resistant forests
Jeremy S. Fried; R. Jamie Barbour; Roger D. Fight; Glenn Christensen; Guy Pinjuv
2008-01-01
There is growing interest in using biomass removed from hazardous fuels reduction treatments in wood-fired electrical generation facilities. An application of FIA BioSum to southwest Oregonâs Klamath ecoregion assessed the financial feasibility of fuel treatment and biomass generation under a range of product prices and fire hazard-motivated silvicultural prescriptions...
The concept: Restoring ecological structure and process in ponderosa pine forests
Stephen F. Arno
1996-01-01
Elimination of the historic pattern of frequent low-intensity fires in ponderosa pine and pine-mixed conifer forests has resulted in major ecological disruptions. Prior to 1900, open stands of large, long-lived, fire-resistant ponderosa pine were typical. These were accompanied in some areas by other fire-dependent species such as western larch. Today, as a result of...
2000-03-30
KENNEDY SPACE CENTER, FLA. -- A NASA helicopter releases 324 gallons of water onto a building in a simulated fire control demonstration. The high-impact-resistant flexible plastic bucket will be used for fire protection on property and buildings at Kennedy Space Center. Known as the "Bambi" bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.
New fire-fighting water bucket releases its load for a demonstration.
NASA Technical Reports Server (NTRS)
2000-01-01
A NASA helicopter releases the contents of the high-impact- resistant flexible plastic bucket it holds. The 324-gallon container will be used for fire protection on property and buildings at Kennedy Space Center. Known as the 'Bambi' bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.
2000-03-30
KENNEDY SPACE CENTER, FLA. -- A NASA helicopter releases 324 gallons of water onto a building in a simulated fire control demonstration. The high-impact-resistant flexible plastic bucket will be used for fire protection on property and buildings at Kennedy Space Center. Known as the "Bambi" bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.
Federal Aviation Administration Plan for Research, Engineering & Development, 1998.
1998-02-01
release rate. • Improved fracture toughness of non-combustible geopolymer composite fire barriers to enable use as interior and secondary composites ...Fire Resistant, Non-Toxic Interior Panels for Evaluation of Heat Release Rate ♦ Improved Fracture Toughness of Non-Combustible Geopolymer Composite ... composites , atmospheric hazards, crash worthiness, fire safety, and forensics capabilities to support accident investigations. Aviation Security R,E&D
Coop, Jonathan D; Parks, Sean A; McClernan, Sarah R; Holsinger, Lisa M
2016-03-01
Large and severe wildfires have raised concerns about the future of forested landscapes in the southwestern United States, especially under repeated burning. In 2011, under extreme weather and drought conditions, the Las Conchas fire burned over several previous burns as well as forests not recently exposed to fire. Our purpose was to examine the influences of prior wildfires on plant community composition and structure, subsequent burn severity, and vegetation response. To assess these relationships, we used satellite-derived measures of burn severity and a nonmetric multidimensional scaling of pre- and post- Las Conchas field samples. Earlier burns were associated with shifts from forested sites to open savannas and meadows, oak scrub, and ruderal communities. These non-forested vegetation types exhibited both resistance to subsequent fire, measured by reduced burn severity, and resilience to reburning, measured by vegetation recovery relative to forests not exposed to recent prior fire. Previous shifts toward non-forested states were strongly reinforced by reburning. Ongoing losses of forests and their ecological values confirm the need for restoration interventions. However, given future wildfire and climate projections, there may also be opportunities presented by transformations toward fire-resistant and resilient vegetation types within portions of the landscape.
Fire Safety in the Low-Gravity Spacecraft Environment
NASA Technical Reports Server (NTRS)
Friedman, Robert
1999-01-01
Research in microgravity (low-gravity) combustion promises innovations and improvements in fire prevention and response for human-crew spacecraft. Findings indicate that material flammability and fire spread in microgravity are significantly affected by atmospheric flow rate, oxygen concentration, and diluent composition. This information can lead to modifications and correlations to standard material-assessment tests for prediction of fire resistance in space. Research on smoke-particle changes in microgravity promises future improvements and increased sensitivity of smoke detectors in spacecraft. Research on fire suppression by extinguishing agents and venting can yield new information on effective control of the rare, but serious fire events in spacecraft.
Continuous resistivity profiling data from Great South Bay, Long Island, New York
Cross, V.A.; Bratton, J.F.; Kroeger, K.D.; Crusius, John; Worley, C.R.
2013-01-01
An investigation of submarine aquifers adjacent to the Fire Island National Seashore and Long Island, New York was conducted to assess the importance of submarine groundwater discharge as a potential nonpoint source of nitrogen delivery to Great South Bay. Over 200 kilometers of continuous resistivity profiling data were collected to image the fresh-saline groundwater interface in sediments beneath the bay. In addition, groundwater sampling was performed at sites (1) along the north shore of Great South Bay, particularly in Patchogue Bay, that were representative of the developed Long Island shoreline, and (2) at sites on and adjacent to Fire Island, a 50-kilometer-long barrier island on the south side of Great South Bay. Other field activities included sediment coring, stationary electrical resistivity profiling, and surveys of in situ pore water conductivity. Results of continuous resistivity profiling surveys are described in this report. The onshore and offshore shallow hydrostratigraphy of the Great South Bay shorelines, particularly the presence and nature of submarine confining units, appears to exert primary control on the dimensions and chemistry of the submarine groundwater flow and discharge zones. Sediment coring has shown that the confining units commonly consist of drowned and buried peat layers likely deposited in salt marshes. Low-salinity groundwater extends from 10 to 100 meters offshore along much of the north and south shores of Great South Bay based on continuous resistivity profiling data, especially off the mouths of tidal creeks and beneath shallow flats to the north of Fire Island adjacent to modern salt marshes. Human modifications of much of the shoreline and nearshore areas along the north shore of the bay, including filling of salt marshes, construction of bulkheads and piers, and dredging of navigation channels, has substantially altered the natural hydrogeology of the bay's shorelines by truncating confining units and increasing recharge near the shore in filled areas. Better understanding of the nature of submarine groundwater discharge along developed and undeveloped shorelines of embayments such as this could lead to improved models and mitigation strategies for nutrient overenrichment of estuaries.
Code of Federal Regulations, 2010 CFR
2010-07-01
... requirements of §§ 75.1107-3 through 75.1107-16. (3) Unattended enclosed motors, controls, transformers... surface, platform, or equivalent. The electrical cables at such equipment shall conform with the...
Termites Are Resistant to the Effects of Fire at Multiple Spatial Scales.
Avitabile, Sarah C; Nimmo, Dale G; Bennett, Andrew F; Clarke, Michael F
2015-01-01
Termites play an important ecological role in many ecosystems, particularly in nutrient-poor arid and semi-arid environments. We examined the distribution and occurrence of termites in the fire-prone, semi-arid mallee region of south-eastern Australia. In addition to periodic large wildfires, land managers use fire as a tool to achieve both asset protection and ecological outcomes in this region. Twelve taxa of termites were detected by using systematic searches and grids of cellulose baits at 560 sites, clustered in 28 landscapes selected to represent different fire mosaic patterns. There was no evidence of a significant relationship between the occurrence of termite species and time-since-fire at the site scale. Rather, the occurrence of species was related to habitat features such as the density of mallee trees and large logs (>10 cm diameter). Species richness was greater in chenopod mallee vegetation on heavier soils in swales, rather than Triodia mallee vegetation of the sandy dune slopes. At the landscape scale, there was little evidence that the frequency of occurrence of termite species was related to fire, and no evidence that habitat heterogeneity generated by fire influenced termite species richness. The most influential factor at the landscape scale was the environmental gradient represented by average annual rainfall. Although termites may be associated with flammable habitat components (e.g. dead wood), they appear to be buffered from the effects of fire by behavioural traits, including nesting underground, and the continued availability of dead wood after fire. There is no evidence to support the hypothesis that a fine-scale, diverse mosaic of post-fire age-classes will enhance the diversity of termites. Rather, termites appear to be resistant to the effects of fire at multiple spatial scales.
Termites Are Resistant to the Effects of Fire at Multiple Spatial Scales
Avitabile, Sarah C.; Nimmo, Dale G.; Bennett, Andrew F.; Clarke, Michael F.
2015-01-01
Termites play an important ecological role in many ecosystems, particularly in nutrient-poor arid and semi-arid environments. We examined the distribution and occurrence of termites in the fire-prone, semi-arid mallee region of south-eastern Australia. In addition to periodic large wildfires, land managers use fire as a tool to achieve both asset protection and ecological outcomes in this region. Twelve taxa of termites were detected by using systematic searches and grids of cellulose baits at 560 sites, clustered in 28 landscapes selected to represent different fire mosaic patterns. There was no evidence of a significant relationship between the occurrence of termite species and time-since-fire at the site scale. Rather, the occurrence of species was related to habitat features such as the density of mallee trees and large logs (>10 cm diameter). Species richness was greater in chenopod mallee vegetation on heavier soils in swales, rather than Triodia mallee vegetation of the sandy dune slopes. At the landscape scale, there was little evidence that the frequency of occurrence of termite species was related to fire, and no evidence that habitat heterogeneity generated by fire influenced termite species richness. The most influential factor at the landscape scale was the environmental gradient represented by average annual rainfall. Although termites may be associated with flammable habitat components (e.g. dead wood), they appear to be buffered from the effects of fire by behavioural traits, including nesting underground, and the continued availability of dead wood after fire. There is no evidence to support the hypothesis that a fine-scale, diverse mosaic of post-fire age-classes will enhance the diversity of termites. Rather, termites appear to be resistant to the effects of fire at multiple spatial scales. PMID:26571383
Horn, Katherine C.; Eubanks, Micky D.; Siemann, Evan
2013-01-01
Biotic interactions are often important in the establishment and spread of invasive species. In particular, competition between introduced and native species can strongly influence the distribution and spread of exotic species and in some cases competition among introduced species can be important. The Caribbean crazy ant, Nylanderia fulva, was recently introduced to the Gulf Coast of Texas, and appears to be spreading inland. It has been hypothesized that competition with the red imported fire ant, Solenopsis invicta, may be an important factor in the spread of crazy ants. We investigated the potential of interspecific competition among these two introduced ants by measuring interspecific aggression between Caribbean crazy ant workers and workers of Solenopsis invicta. Specifically, we examined the effect of body size and diet on individual-level aggressive interactions among crazy ant workers and fire ants. We found that differences in diet did not alter interactions between crazy ant workers from different nests, but carbohydrate level did play an important role in antagonistic interactions with fire ants: crazy ants on low sugar diets were more aggressive and less likely to be killed in aggressive encounters with fire ants. We found that large fire ants engaged in fewer fights with crazy ants than small fire ants, but fire ant size affected neither fire ant nor crazy ant mortality. Overall, crazy ants experienced higher mortality than fire ants after aggressive encounters. Our findings suggest that fire ant workers might outcompete crazy ant workers on an individual level, providing some biotic resistance to crazy ant range expansion. However, this resistance may be overcome by crazy ants that have a restricted sugar intake, which may occur when crazy ants are excluded from resources by fire ants. PMID:23776702
Repetitive Series Interrupter II.
1977-07-01
nated by other authorized documents. The citation of trade names and names of manufacturers is this report is not to be construed as official... intergrating inductor Magnet circuit load resistance Pulse-forming network load resistance Fault network load resistance Time delay between TUT fire and
Journal of Naval Science. Volume 2, Number 1
1976-01-01
has defined a probability distribution function which fits this type of data and forms the basis for statistical analysis of test results (see...Conditions to Assess the Performance of Fire-Resistant Fluids’. Wear, 28 (1974) 29. J.N.S., Vol. 2, No. 1 APPENDIX A Analysis of Fatigue Test Data...used to produce the impulse response and the equipment required for the analysis is relatively simple. The methods that must be used to produce
NASA Technical Reports Server (NTRS)
Enders, J. H.
1978-01-01
Aircraft safety is reviewed by first establishing a perspective of air transportation accidents as a function of calendar year, geographic area, and phase of flight, and then by describing the threats to safety and NASA research underway in the three representative areas of engine operational problems, meteorological phenomena, and fire. Engine rotor burst protection, aircraft nacelle fire extinguishment, the aircraft-weather interface, severe weather wind shears and turbulence, clear air turbulence, and lightning are among the topics covered. Fire impact management through fire resistant materials technology development is emphasized.
Resistance after firing protected electric match. [Patent application
Montoya, A.P.
1980-03-20
An electric match having electrical leads embedded in flame-producing compound is protected against an accidental resistance across the leads after firing by a length of heat-shrinkable tubing encircling the match body and having a skirt portion extending beyond the leads. The heat of the burning match and an adjacent thermal battery causes the tubing to fold over the end of the match body, covering the ends of the leads and protecting them from molten pieces of the battery.
Maleimido substituted cyclotriphosphazene resins for fire and heat resistant composites
NASA Technical Reports Server (NTRS)
Kumar, D.; Fohlen, G. M.; Parker, J. A.
1983-01-01
A new class of fire- and heat-resistant matrix resins have been synthesized by the thermal polymerization of maleimido substituted phenoxycyclotriphosphazenes. The resins have exhibited a char yield of 82 percent at 800 C in nitrogen and 81 percent at 700 C in air. Graphite-fabric laminates based on a resin of this class have shown a limiting oxygen index of 100 percent even at 300 C. Details of the fabrication of the resins and the composites and testing procedures are discussed.
David V. SANDBERG; Franklin R. Ward
1981-01-01
This publication presents tables on the behavior of fire and the resistance of fuels to control. The information is to be used with the photos in the publication, "Photo Series for Quantifying Forest Residues in the Coastal Douglas-firâHemlock Type, Coastal Douglas-firâHardwood Type" (Maxwell, Wayne G.; Ward, Franklin R. 1976. Gen. Tech. Rep. PNW-GTR-051....
New Approaches to Maximizing Thermo-oxidation Resistance of Polycyanurate Networks
2014-08-13
Resveratrol -based CE Delivers Exceptional Thermal Stability and Fire Resistance Acknowledgements: Strategic Environmental Research and Development...CH2-CH2- (dihydro resveratrol ) OH OH HO R OCN OCN NCO R Char (65%) Cure at 250C N N N N N N O O O R N N N Resveratrol cyanate ester* Resveratrol ...triazine thermoset resin > 450C Fire ( resveratrol ) • Polyphenolic antioxidant used as a dietary supplement • Extracted from seaweed, red grapes, red wine
Crash-resistant fuel system effectiveness in civil helicopter crashes.
Hayden, Mark S; Shanahan, Dennis F; Chen, Li-Hui; Baker, Susan P
2005-08-01
Crash-resistant fuel systems (CRFS) have demonstrated close to 100% effectiveness in survivable crashes of Army helicopters, but the technology has been slow to transfer into the civil helicopter arena. Federal standards for civil helicopter CRFS are less stringent than those for military helicopters. A reduction in standards for CRFS in military helicopters is being considered. The goal of this study was to determine whether crashes of civil helicopters with CRFS are less likely to result in post-crash fire than crashes of those without. Crashes of civil helicopters during 1982-2004 were analyzed, comparing Bell 206 helicopters manufactured with CRFS with Aerospatial 350 helicopters manufactured during the same period (post-1981), but lacking CRFS. Bell 206 helicopters with CRFS were also compared with earlier models without CRFS. The highest proportion of crashes with post-crash fires (11.3%) was in AS-350s manufactured after 1981 (non-CRFS), and the lowest (3.7%) was in Bell 206s (with CRFS) [unadjusted risk ratio (RR) = 3.3, 95% confidence interval (CI) = 1.04, 10.50; adjusted for light and weather, RR = 2.81, Cl = 0.82, 9.69]. Earlier models of Bell 206s without CRFS had higher risk of post-crash fire than post-1981 models with CRFS (7.4% vs. 3.7%; adjusted RR = 2.11, Cl = 0.82, 5.45). The results of this study suggest a better performance, in terms of post-crash fire prevention, of CRFS-equipped civil helicopters as compared with those without CRFS. It is possible that CRFS in civil helicopters have not achieved the same degree of effectiveness as CRFS in military helicopters. CRFS should be used more widely in civil helicopters. The more stringent CRFS requirements for military helicopters should not be reduced without further research.
NASA Astrophysics Data System (ADS)
Ghadzali, N. S.; Ibrahim, M. H. W.; Sani, M. S. H. Mohd; Jamaludin, N.; Desa, M. S. M.; Misri, Z.
2018-04-01
Concrete is the chief material of construction and it is non-combustible in nature. However, the exposure to the high temperature such as fire can lead to change in the concrete properties. Due to the higher temperature, several changes in terms of mechanical properties were observed in concrete such as compressive strength, modulus of elasticity, tensile strength and durability of concrete will decrease significantly at high temperature. The exceptional fire-proof achievement of concrete is might be due to the constituent materials of concrete such as its aggregates. The extensive use of aggregate in concrete will leads to depletion of natural resources. Hence, the use of waste and other recycled and by-product material as aggregates replacements becomes a leading research. This review has been made on the utilization of waste materials in concrete and critically evaluates its effects on the concrete performances during the fire exposure. Therefore, the objective of this paper is to review the previous search work regarding the concrete containing waste material as aggregates replacement when exposed to elevated temperature and come up with different design recommendations to improve the fire resistance of structures.
Rubberized, Brominated Epoxies
NASA Technical Reports Server (NTRS)
Gilwee, W.; Kourtides, D.; Parker, J.; Nir, Z.
1985-01-01
Graphite/epoxy composite materials made with resins containing bromine and rubber additives. New composites tougher and more resistant to fire. Flame resistance increased by introducing bromine via commercial brominated flame-retartant polymeric additives.
Charring rate of wood exposed to a constant heat flux
R. H. White; H. C. Tran
1996-01-01
A critical factor in the fire endurance of a wood member is its rate of charring. Most available charring rate data have been obtained using the time-temperature curves of the standard fire resistance tests (ASTM E 119 and ISO 834) to define the fire exposure. The increased use of heat release calorimeters using exposures of constant heat flux levels has broadened the...
On the use of satellite VEGETATION time series for monitoring post fire vegetation recovery
NASA Astrophysics Data System (ADS)
de Santis, F.; Didonna, I.
2009-04-01
Fire is one of the most critical factors of disturbance in worldwide ecosystems. The effects of fires on soil, plants, landscape and ecosystems depend on many factors, among them fire frequency, fire severity and plant resistance. The characterization of vegetation post-fire behaviour is a fundamental issue to model and evaluate the fire resilience, which the ability of vegetation to recover after fire. Recent changes in fire regime, due to abandonment of local land use practice and climate change, can induce significant variations in vegetation fire resilience. In the Mediterranean-type communities, post fire vegetation trends have been analysed in a wide range of habitats, although pre- and post-fire investigation has been widely performed at stand level. But, factors controlling regeneration at the landscape scale are less well known. In this study, a time series of normalized difference vegetation index (NDVI) data derived from SPOT-VEGETATION was used to examine the recovery characteristics of fire affected vegetation in some test areas of the Mediterranean ecosystems of Southern Italy. The vegetation indices operate by contrasting intense chlorophyll pigment absorption in the red against the high reflectance of leaf mesophyll in the near infrared. SPOT-VEGETATION Normalized Difference Vegetation Index (NDVI) data from 1998 to 2005 were analyzed in order to evaluate the resilient effects in a some significant test sites of southern Italy. In particular, we considered: (i) one stable area site, one site affected by one fire during the investigated time window, (iii) one site affected by two consecutive fires during the investigated time window. In order to eliminate the phenological fluctuations, for each decadal composition of each pixel, we focused on the departure NDVId = [NDVI -
NASA Technical Reports Server (NTRS)
Hillenbrand, L. J.; Wray, J. A.
1974-01-01
A program of experimental fires was carried out to establish the advantages offered by new materials for improved fire safety. Four full-scale bedrooms, differing only in the materials used to furnish them, were built and burned to provide comparative data on the fire hazards produced. Cost and availability differences were not considered. The visual evidence provided by TV and photographic coverage of the four experimental room fires showed clearly that the rooms responded very differently to a common ignition condition. Resistance to the ignition and spread of fire was substantially improved in the rooms furnished completely or partially with the new materials.
Li, Chunyan; Tripathi, Pradeep K; Armstrong, William E
2007-01-01
The firing pattern of magnocellular neurosecretory neurons is intimately related to hormone release, but the relative contribution of synaptic versus intrinsic factors to the temporal dispersion of spikes is unknown. In the present study, we examined the firing patterns of vasopressin (VP) and oxytocin (OT) supraoptic neurons in coronal slices from virgin female rats, with and without blockade of inhibitory and excitatory synaptic currents. Inhibitory postsynaptic currents (IPSCs) were twice as prevalent as their excitatory counterparts (EPSCs), and both were more prevalent in OT compared with VP neurons. Oxytocin neurons fired more slowly and irregularly than VP neurons near threshold. Blockade of Cl− currents (including tonic and synaptic currents) with picrotoxin reduced interspike interval (ISI) variability of continuously firing OT and VP neurons without altering input resistance or firing rate. Blockade of EPSCs did not affect firing pattern. Phasic bursting neurons (putative VP neurons) were inconsistently affected by broad synaptic blockade, suggesting that intrinsic factors may dominate the ISI distribution during this mode in the slice. Specific blockade of synaptic IPSCs with gabazine also reduced ISI variability, but only in OT neurons. In all cases, the effect of inhibitory blockade on firing pattern was independent of any consistent change in input resistance or firing rate. Since the great majority of IPSCs are randomly distributed, miniature events (mIPSCs) in the coronal slice, these findings imply that even mIPSCs can impart irregularity to the firing pattern of OT neurons in particular, and could be important in regulating spike patterning in vivo. For example, the increased firing variability that precedes bursting in OT neurons during lactation could be related to significant changes in synaptic activity. PMID:17332000
14 CFR 25.1713 - Fire protection: EWIS.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Electrical Wiring Interconnection Systems (EWIS) § 25.1713... used during emergency procedures must be fire resistant. (c) Insulation on electrical wire and electrical cable, and materials used to provide additional protection for the wire and cable, installed in...
Burn-Resistant, Strong Metal-Matrix Composites
NASA Technical Reports Server (NTRS)
Stoltzfus, Joel M.; Tayal, Moti J.
2003-01-01
Ceramic particulate fillers increase the specific strengths and burn resistances of metals: This is the conclusion drawn by researchers at Johnson Space Center's White Sands Test Facility. The researchers had theorized that the inclusion of ceramic particles in metal tools and other metal objects used in oxygen-rich atmospheres (e.g., in hyperbaric chambers and spacecraft) could reduce the risk of fire and the consequent injury or death of personnel. In such atmospheres, metal objects act as ignition sources, creating fire hazards. However, not all metals are equally hazardous: some are more burn-resistant than others are. It was the researchers purpose to identify a burn-resistant, high-specific-strength ceramic-particle/metal-matrix composite that could be used in oxygen-rich atmospheres. The researchers studied several metals. Nickel and cobalt alloys exhibit high burn resistances and are dense. The researchers next turned to ceramics, which they knew do not act as ignition sources. Unlike metals, ceramics are naturally burn-resistant. Unfortunately, they also exhibit low fracture toughnesses.
The Development of a Thermally Enhanced Emergency Fire Shelter
NASA Technical Reports Server (NTRS)
Fody, Joshua M.; Calomino, Anthony M.; Daryabeigi, Kamran; Bruce III, Walter E.; Wells, John M.; Wusk, Mary E.; Miller, Stephen D.
2017-01-01
Since its founding in 1905, the U.S. Forest Service has been responsible for maintaining public lands. The Forest Service and other public lands agencies respond to an average of 73,000 wildfires per year, and responding firefighters are required to carry a number of safety gear items, including the M2002 emergency fire shelter. The emergency fire shelter is intended to serve as a last resort means of protection in case a firefighter's escape route has been compromised in the face of an approaching flame front. No fire shelter deployment tragedy has been more costly than the 2013 Yarnell Hill fire in Arizona, where 19 members of the Granite Mountain Hotshots perished. After the tragedy at Yarnell Hill, the Forest Service decided to expedite the next redesign cycle of the fire shelter in order to improve its ability to withstand direct contact with flames. Engineers at NASA Langley Research Center have spent the better part of a decade developing flexible thermal materials for use in inflatable aerodynamic decelerators and have demonstrated their performance in the IRVE-2 and IRVE-3 flight programs (Inflatable Reentry Vehicle Experiment). NASA engineers recognized an opportunity to leverage their experience and knowledge with flexible thermal protection systems to potentially improve the fire shelter's resistance to direct flame contact, and have been working directly with the U.S. Forest Service to achieve this goal. They launched the CHIEFS project (Convective Heating Improvement for Emergency Fire Shelters) in 2014. Over the past three years, CHIEFS has screened over 270 unique material layups, and tested over 30 unique full scale shelter concepts in an effort to achieve a game changing improvement to the thermal protection of the fire shelter, while maintaining minimal mass and volume. This paper will discuss CHIEFS' 1st and 2nd generation fire shelter development efforts and test results.
Structural Health Monitoring of M1114 High Mobility Multipurpose Wheeled Vehicle Armor System
2012-03-01
compressional waves or compression waves (Russell, 1999). Pulse Echo Pulse echo method uses the transducer to perform both the sending and the...monolithic system of pure steel will not be sufficient because it would become too heavy and compromise its maneuverability and nimbleness. In order to...produce a limited number of M1114’s with hardened steel armor with bullet-resistant glass for the passenger cabinet against small arms fire. Even with its
High temperature structural sandwich panels
NASA Astrophysics Data System (ADS)
Papakonstantinou, Christos G.
High strength composites are being used for making lightweight structural panels that are being employed in aerospace, naval and automotive structures. Recently, there is renewed interest in use of these panels. The major problem of most commercial available sandwich panels is the fire resistance. A recently developed inorganic matrix is investigated for use in cases where fire and high temperature resistance are necessary. The focus of this dissertation is the development of a fireproof composite structural system. Sandwich panels made with polysialate matrices have an excellent potential for use in applications where exposure to high temperatures or fire is a concern. Commercial available sandwich panels will soften and lose nearly all of their compressive strength temperatures lower than 400°C. This dissertation consists of the state of the art, the experimental investigation and the analytical modeling. The state of the art covers the performance of existing high temperature composites, sandwich panels and reinforced concrete beams strengthened with Fiber Reinforced Polymers (FRP). The experimental part consists of four major components: (i) Development of a fireproof syntactic foam with maximum specific strength, (ii) Development of a lightweight syntactic foam based on polystyrene spheres, (iii) Development of the composite system for the skins. The variables are the skin thickness, modulus of elasticity of skin and high temperature resistance, and (iv) Experimental evaluation of the flexural behavior of sandwich panels. Analytical modeling consists of a model for the flexural behavior of lightweight sandwich panels, and a model for deflection calculations of reinforced concrete beams strengthened with FRP subjected to fatigue loading. The experimental and analytical results show that sandwich panels made with polysialate matrices and ceramic spheres do not lose their load bearing capability during severe fire exposure, where temperatures reach several hundred degrees Centigrade. Hence the material has excellent potential for various types of applications. The analytical predictions from both models provide reasonably accurate results. Glass, AR-glass, carbon and Nicalon tows and carbon fabrics could be successfully used as skin reinforcements increasing the flexural stiffness and strength of the core. No occurrence of fiber delamination was observed.
Wicklein, Bernd; Kocjan, Andraž; Salazar-Alvarez, German; Carosio, Federico; Camino, Giovanni; Antonietti, Markus; Bergström, Lennart
2015-03-01
High-performance thermally insulating materials from renewable resources are needed to improve the energy efficiency of buildings. Traditional fossil-fuel-derived insulation materials such as expanded polystyrene and polyurethane have thermal conductivities that are too high for retrofitting or for building new, surface-efficient passive houses. Tailored materials such as aerogels and vacuum insulating panels are fragile and susceptible to perforation. Here, we show that freeze-casting suspensions of cellulose nanofibres, graphene oxide and sepiolite nanorods produces super-insulating, fire-retardant and strong anisotropic foams that perform better than traditional polymer-based insulating materials. The foams are ultralight, show excellent combustion resistance and exhibit a thermal conductivity of 15 mW m(-1) K(-1), which is about half that of expanded polystyrene. At 30 °C and 85% relative humidity, the foams retained more than half of their initial strength. Our results show that nanoscale engineering is a promising strategy for producing foams with excellent properties using cellulose and other renewable nanosized fibrous materials.
Defense Standardization Program Journal. April/September 2012
2012-01-01
were magnified. In 1905, a committee of the National Fire Protection Association established a national standard for the diameter and threads per inch...for fire hydrants and hose couplings. The standard specifies that fire hydrants have 2.5-inch hose connections with 7.5 threads per inch and that...dsp.dla.mil I Field of view, lens material haze, luminous transmittance, and lens abrasion resistance (APR) I Communications (APR) I Fogging (APR
Thermoelectric Generator Used in Fire-Alarm Temperature Sensing
NASA Astrophysics Data System (ADS)
Wu, Wenchang; Du, Zhengliang; Cui, Jiaolin; Shi, Zhongtao; Deng, Yuan
2015-06-01
Here we present a thermoelectric (TE) generator used in fire-alarm temperature sensing. The TE module, a core component of this generator, has a sandwich-like structure consisting of a Cu/Sn95Ag5/coated Ni/sprayed Ni/TE/sprayed Ni/coated Ni/Sn95Ag5/Cu multilayer that exhibits a low internal resistance of 5.5 Ω to 5.9 Ω and a contact resistance of 0.51 Ω to 0.91 Ω at room temperature (RT), enabling the TE generator to attain an open-circuit voltage ( V op) of 1.50 V at RT and 2.97 V at ~90°C. Moreover, its maximum output power ( p max) was estimated to be 11.6 mW and 428.7 mW, respectively, for a temperature difference (Δ T) of 9.3°C and 52.9°C. These values are comparable to those for the bulk TE generator developed by Thermonamic. According to these figures, we obtain corresponding power densities of ~7.25 × 103 nW/mm2 and 2.68 × 105 nW/mm2, respectively. Although there is still much room to improve the performance of the generator when the source temperature rises above 90°C, the output voltages and maximum output powers attained in the current testing conditions are large enough to drive small electronic devices such as fire-alarm systems etc. Therefore, it is believed that the fabrication technology and designed structure of the generator are appropriate for such applications.
Integrated Control of Fire Blight with Bacterial Antagonists and Oxytetracycline
USDA-ARS?s Scientific Manuscript database
In the Pacific Northwest of the United States, the antibiotic streptomycin provided excellent control of fire blight until resistant isolates of Erwinia amylovora were prevalent. Oxytetracycline (Mycoshield) is now sprayed as an alternative antibiotic. We found that the duration of inhibitory acti...
Integrated Control of Fire Blight with Antagonists and Oxytetracycline
USDA-ARS?s Scientific Manuscript database
In the Pacific Northwest of the United States, the antibiotic streptomycin provided excellent control of fire blight until resistant isolates of Erwinia amylovora arose. Oxytetracycline (Mycoshield) is now sprayed as an alternative antibiotic. We found that the duration of inhibitory activity of o...
NASA Technical Reports Server (NTRS)
Kumar, Devendra (Inventor); Fohlen, George M. (Inventor); Parker, John A. (Inventor)
1987-01-01
4-Aminophenoxy cyclotriphosphazenes are reacted with maleic anhydride to produce maleamic acids which are converted to the maleimides. The maleimides are polymerized. By selection of starting materials (e.g., hexakis amino or trisaminophenoxy trisphenoxy cyclotriphosphazenes), selection of molar proportions of reactants, use of mixtures of anhydrides and use of dianhydrides as bridging groups a variety of maleimides and polymers are produced. The polymers have high limiting oxygen indices, high char yields and other useful heat and fire resistant properties making them useful as, for example, impregnants of fabrics.
Water Resistant Container Technical Basis Document for the TA-55 Criticality Safety Program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, Paul Herrick; Teague, Jonathan Gayle
Criticality safety at TA-55 relies on nuclear material containers that are water resistant to prevent significant amounts of water from coming into contact with fissile material in the event of a fire that causes a breach of glovevbox confinement and subsequent fire water ingress. A “water tight container” is a container that will not allow more than 50ml of water ingress when fully submerged, except when under sufficient pressure to produce structural discontinuity. There are many types of containers, welded containers, hermetically sealed containers, filtered containers, etc.
Aerospace materials for nonaerospace applications
NASA Technical Reports Server (NTRS)
Johnston, R. L.; Dawn, F. S.
1974-01-01
Many of the flame-resistant nonmetallic materials that were developed for the Apollo and Skylab programs are discussed for commercial and military applications. Interchanges of information are taking place with the government agencies, industries, and educational institutions, which are interested in applications of fire-safe nonmetallic materials. These materials are particularly applicable to the design of aircraft, mass transit interiors, residential and public building constructions, nursing homes and hospitals, and to other fields of fire safety applications. Figures 22, 23 and 24 show the potential nonaerospace applications of flame-resistant aerospace materials are shown.
Anthropogenic fire drives the evolution of seed traits
Gómez-González, Susana; Torres-Díaz, Cristian; Bustos-Schindler, Carlos; Gianoli, Ernesto
2011-01-01
Fire is a major disturbance affecting ecosystems worldwide. Phylogenetic studies have shown that the evolution of seed persistence (fire resistance) is associated with fire frequency or severity. However, the existence of specific seed traits resulting from natural selection mediated by fire remains a key question in plant evolution. We evaluated the role of fire in the evolution of seed traits from a microevolutionary perspective, using as a study system a native forb from the Chilean matorral, where fire is a novel, anthropogenic disturbance. We show that anthropogenic fires are shaping the evolution of seed traits such as pubescence and shape. Among-population variation in seed pubescence, shape, and pericarp thickness was strongly associated with fire frequency, and within a population, fire selected those plants with more pubescent seeds, thicker pericarps, and less rounded seeds. Seed pubescence and shape were shown to be heritable traits. Our findings provide insights into the understanding of the evolution of seed traits in fire-prone environments and demonstrate that human-made fires can be driving evolutionary changes in plant species from ecosystems where fires do not occur naturally. PMID:22065739
Anthropogenic fire drives the evolution of seed traits.
Gómez-González, Susana; Torres-Díaz, Cristian; Bustos-Schindler, Carlos; Gianoli, Ernesto
2011-11-15
Fire is a major disturbance affecting ecosystems worldwide. Phylogenetic studies have shown that the evolution of seed persistence (fire resistance) is associated with fire frequency or severity. However, the existence of specific seed traits resulting from natural selection mediated by fire remains a key question in plant evolution. We evaluated the role of fire in the evolution of seed traits from a microevolutionary perspective, using as a study system a native forb from the Chilean matorral, where fire is a novel, anthropogenic disturbance. We show that anthropogenic fires are shaping the evolution of seed traits such as pubescence and shape. Among-population variation in seed pubescence, shape, and pericarp thickness was strongly associated with fire frequency, and within a population, fire selected those plants with more pubescent seeds, thicker pericarps, and less rounded seeds. Seed pubescence and shape were shown to be heritable traits. Our findings provide insights into the understanding of the evolution of seed traits in fire-prone environments and demonstrate that human-made fires can be driving evolutionary changes in plant species from ecosystems where fires do not occur naturally.
U.S. Air Force Aircrew Flight Protective Eyewear Program
2013-02-01
MIL-DTL-32000), fire - resistant hydraulic fluid (MIL-PRF-46170), petroleum-based hydraulic fluid (MIL-PRF-6083), gasoline (87% octane), motor oil...UPLC installed. ABRASION FPE spectacles and goggles shall maximize resistance to scratching/ abrasion to minimize interference with vision...Visual Area ................................................................................. 2 3.0 BALLISTIC AND IMPACT RESISTANCE : BALLISTIC
30 CFR 57.4533 - Mine opening vicinity.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and... materials; or (b) Constructed to meet a fire resistance rating of no less than one hour; or (c) Provided...
Plant community diversity and composition provide little resistance to Juniperus encroachment
Amy C. Ganguli; David M. Engle; Paul M. Mayer; Eric C. Heligren
2008-01-01
Widespread encroachment of the fire-intolerant species Juniperus virginiana L. into North American grasslands and savannahs where fire has largely been removed has prompted the need to identify mechanisms driving J. virginiana encroachment. We tested whether encroachment success of J. virginiana is related to...
ERIC Educational Resources Information Center
National Clearinghouse for Educational Facilities, 2009
2009-01-01
This publication discusses conditions that feed wildfires, how a building catches fire, determining the school's risk, creating a survivable space for the school, the importance of maintenance, the fire-resistant school, meeting code requirements, and related flood and mudslide risks. Much of this publication has been adapted for schools from the…
Post-processing flame-retardant for polyurethane
NASA Technical Reports Server (NTRS)
Monaghan, P.; Sidman, K. R.
1980-01-01
Treatment of polyurethane form with elastomer formulation after processing makes foam fire resistant without compromising physical properties. In testing, once ignition source is removed, combustion stops. Treatment also prevents molten particle formation, generates no smoke or toxic gases in fire, and does not deteriorate under prolonged exposure to Sun.
The effects of prescribed burning on fire hazard in the chaparral: toward a new conceptual synthesis
Anthony T. Dunn
1989-01-01
Prescribed burning for fire hazard reduction in the chaparral is predicated on the belief that young fuels (20 years old and less) are highly resistant to burning. To test this belief, a data base search of large fires in San Diego County between 1940 and 1985 was conducted to locate reburns of young chaparral fuels greater than 1000 acres (400 ha) in extent. Of the...
New Technology for the Fire Attire
NASA Technical Reports Server (NTRS)
1982-01-01
Although little can be done to reduce the risks of firefighting, something can be done to curb the injuries and fatalities. This is the goal of Project FIRES, a program jointly sponsored by NASA and the Federal Emergency Management Agency's U.S. Fire Administration with technical management provided by Marshall Space Flight Center. Project FIRES (Firefighter's Integrated Response Equipment System) involves applications of advanced materials and design concepts, derived from Apollo to update existing gear which does not adequately protect against many of the hazards encountered in fire suppression activities. A major focus of the effort involves application to the FIRES ensemble of lightweight, fire-resistant, heat-protective materials originally developed for use in astronauts' space suits or in spacecraft components which require thermal protection. Data from the fourteen municipal fire departments participating in the field evaluation will form a basis for development of new nationwide protective ensemble students.
NASA Astrophysics Data System (ADS)
Burlacu, L.; Cimpoeşu, N.; Bujoreanu, L. G.; Lohan, N. M.
2017-08-01
Ni-Ti shape memory alloys (SMAs) are intelligent alloys which demonstrate unique properties, such as shape memory effect, two-way shape memory effect, super-elasticity and vibration damping which, accompanied by good processability, excellent corrosion resistance and biocompatibility as well as fair wear resistance and cyclic stability, enabled the development of important industrial applications (such as sensors, actuators, fasteners, couplings and valves), medical applications (such as stents, bone implants, orthodontic archwires, minimal invasive surgical equipment) as well as environmental health and safety devices (anti-seismic dampers, fire safety devices). The phase transitions in Ni-Ti SMAs are strongly influenced by processing methods, chemical compositions and thermomechanical history. This paper presents a study of the effects of heat treatment on the mechanical and thermal properties of commercial Ni-Ti shape memory alloy (SMA). The experimental work involved subjecting a SMA rod to heat-treatment consisting in heating up to 500°C, 10 minutes-maintaining and water quenching. Mechanical properties were highlighted by microhardness tests while thermal characteristics were emphasized by differential scanning calorimetry (DSC). The presence of chemical composition fluctuations was checked by X-ray energy dispersive spectroscopy performed with an EDAX Bruker analyzer.
Research on Fire-Resistant Diesel Fuel Flammability Mitigation Mechanisms
1982-12-01
Naegeli U.S. Army Fuels and Lubricants Research Laboratory Southwest Research Institute San Antonio, Texas Under Contract to U.S. Army Mobility Equipment...David Naegeli DAAK70-80-C-0001 DAAK70-82-C-0001 9. PERFORMING ORGANIZATION NAME AND ADDRESSES 10. PROGRAM ELEMENT, PROJECT. TASK U.S. Army Fuels and...water-containing diesel fuel blends. 43 VI. LIST OF REFERENCES 1. Weatherford, W.D., Jr., Fodor, G.E., Naegeli , D.W., Wright, B.R., Owens, E.C., and
Factors in adoption of a fire department wellness program: champ-and-chief model.
Kuehl, Hannah; Mabry, Linda; Elliot, Diane L; Kuehl, Kerry S; Favorite, Kim C
2013-04-01
To identify and evaluate determinants of fire departments' wellness program adoption. The Promoting Healthy Lifestyles: Alternative Models' Effects fire service wellness program was offered for free to all medium-sized fire departments in Oregon and Washington. An invitation to participate was mailed to key fire department decision makers (chief, union president, and wellness officer). These key decision makers from 12 sites that adopted the program and 24 matched nonadopting sites were interviewed and results were analyzed to define adoption determinants. Three adoption requirements were identified: (1) mailer connection, (2) local firefighter wellness champion, and (3) willing fire chief, whereas a fourth set of organizational factors had little or no impact on adoption including previous and ongoing wellness activities, financial pressures, and resistance to change. Findings identified determinants of medium-sized fire service wellness program adoption.
Resource-dependent growth models for Sierran mixed-conifer saplings
S.W. Bigelow; M.P. North; W.R. Horwath
2009-01-01
Thinning to reduce wildfire hazard is a common management practice in frequent-fire forests of the American west, but it is uncertain whether projects will help regenerate fire-resistant, shade-intolerant pines. We studied naturally established saplings of six conifer species in mixed-conifer forest in northern California, USA to...
Increasing Fire Safety of Epoxies
NASA Technical Reports Server (NTRS)
Kourtides, D. A.; Mikroyannidis, J. A.
1985-01-01
Epoxy with increased resistance to fire made by reacting any of three commercial epoxide monomers with curing agent consisting of mixture of isomers called "DCEPD". Curing agent incorporates phosphorus and chlorine directly into crosslinking part of polymer. DCEPD produced by nitrating precursor phosphonylmethyl benzene, then reducing resulting isomeric mixture of dinitro compounds.
Code of Federal Regulations, 2010 CFR
2010-01-01
... chapter. (2) Each turbine engine must comply with one of the following: (i) Sections 33.76, 33.77 and 33... any engine individually in flight, except that, for turbine engine installations, the means for... might be exposed to fire must be at least fire-resistant. If hydraulic propeller feathering systems are...
Budagovsky 9 rootstock: uncovering a novel resistance to fire blight
USDA-ARS?s Scientific Manuscript database
Budagovsky 9 (B.9) apple rootstock, displayed a high level of susceptibility (similar to M.9 rootstock) to fire blight bacteria (Erwinia amylovora) when leaves of non-grafted B.9 plants were inoculated. However, when older B.9 rootstock tissue was inoculated directly with E. amylovora, rootstock tis...
29 CFR 1910.110 - Storage and handling of liquefied petroleum gases.
Code of Federal Regulations, 2012 CFR
2012-07-01
... dehydrators or dryers. (13) Ventilation, adequate—when specified for the prevention of fire during normal..., buildings, or separate fire divisions of buildings used exclusively for housing internal combustion engines..., diaphragms, etc., shall be of such quality as to be resistant to the action of liquefied petroleum gas under...
29 CFR 1910.110 - Storage and handling of liquefied petroleum gases.
Code of Federal Regulations, 2014 CFR
2014-07-01
... dehydrators or dryers. (13) Ventilation, adequate—when specified for the prevention of fire during normal..., buildings, or separate fire divisions of buildings used exclusively for housing internal combustion engines..., diaphragms, etc., shall be of such quality as to be resistant to the action of liquefied petroleum gas under...
29 CFR 1910.110 - Storage and handling of liquefied petroleum gases.
Code of Federal Regulations, 2013 CFR
2013-07-01
... dehydrators or dryers. (13) Ventilation, adequate—when specified for the prevention of fire during normal..., buildings, or separate fire divisions of buildings used exclusively for housing internal combustion engines..., diaphragms, etc., shall be of such quality as to be resistant to the action of liquefied petroleum gas under...
46 CFR 164.007-9 - Procedure for approval.
Code of Federal Regulations, 2013 CFR
2013-10-01
... the Fire Research section of the National Bureau of Standards, Washington, DC 20234, and shall advise.... (1) If the manufacturer desires to have the test conducted at some laboratory other than the National... sample or samples for the fire resistance test will be given at this time, together with the estimated...
46 CFR 164.007-9 - Procedure for approval.
Code of Federal Regulations, 2014 CFR
2014-10-01
... the Fire Research section of the National Bureau of Standards, Washington, DC 20234, and shall advise.... (1) If the manufacturer desires to have the test conducted at some laboratory other than the National... sample or samples for the fire resistance test will be given at this time, together with the estimated...
NASA Technical Reports Server (NTRS)
2001-01-01
Through a partnership with Unitika Ltd., NASA's Langley Research Center created a foam based on high temperature resistant polyimide chemistry. Licensed non-exclusively to SORDAL, Inc., the low-density foam, named TEEK, can be processed into forms or used to fill structures such as honeycomb. TEEK offers superior insulation and support qualities, with heat and flame resistance abilities.TEEK is a practical selection for hull insulation in the shipbuilding industry, with numerous potential applications in aerospace applications, fire-resistant construction materials, and a wide range of consumer products that will improve safety and energy efficiency. Other opportunities are available in the areas of automotive coatings and sealants, electrical components, and recreational equipment. SORDAL has introduced its new product in several different forms, under the name "SOLREX". The company is developing a new product called SORDAL Paper(TM) that will be used in conjunction with the polyimide foam to offer thermal protection in various products, such as fire resistant garments and prosthetics.
NASA Astrophysics Data System (ADS)
Shinde, Manish; Pawar, Amol; Karmakar, Soumen; Seth, Tanay; Raut, Varsha; Rane, Sunit; Bhoraskar, Sudha; Amalnerkar, Dinesh
2009-11-01
Uncapped silver nanoparticles were synthesized by DC arc thermal plasma technique. The synthesized nanoparticles were structurally cubic and showed wide particle size variation (between 20-150 nm). Thick film paste formulated from such uncapped silver nanoparticles was screen-printed on alumina substrates and the resultant `green' films were fired at different firing temperatures. The films fired at 600 °C revealed better microstructure properties and also yielded the lowest value of sheet resistance in comparison to those corresponding to conventional peak firing temperature of 850 °C. Our findings directly support the role of silver nanoparticles in substantially depressing the operative peak firing temperature involved in traditional conductor thick films technology.
NASA Astrophysics Data System (ADS)
Drews, M. J.
Despite a reduction in Federal regulatory activity, research concerned with flame retardancy and smoke suppression in the private sector appears to be increasing. This trend seem related to the increased utilization of plastics for end uses which traditionally have employed metal or wood products. As a result, new markets have appeared for thermally stable and fire resistance thermoplastic materials, and this in turn has spurred research and development activity. In addition, public awareness of the dangers associated with fire has increased as a result of several highly publicized hotel and restaurant fires within the past two years. The consumers recognition of flammability characteristics as important materials property considerations has increased. The current status of fire and smoke retardant chemistry and research are summarized.
Manninen, R; Huovinen, P; Nissinen, A
1998-04-01
The performance of disk diffusion testing of Haemophilus influenzae was evaluated in 20 laboratories. Thirteen disk-medium-breakpoint-inoculum modifications were used in Finnish clinical microbiology laboratories. The performance of various methods was evaluated by testing a susceptible control strain and one with non-beta-lactamase-mediated ampicillin resistance 10 times in 16 laboratories. Gaps in millimeters were measured between these two groups of results. The strains were separated by a gap of at least 5 mm in 8/16 laboratories testing ampicillin, in 7/15 laboratories testing cefaclor, in 5/ 16 laboratories testing cefuroxime, and in 15/16 laboratories testing trimethoprim-sulfa. Detection of ampicillin resistance was better with 2.5 microg tablets than with 10 microg disks or 33 microg tablets. For MIC-determinations, 785 isolates and their disk diffusion results were collected. None of the 12 clinical isolates with non-beta-lactamase-mediated ampicillin resistance was detected as resistant in the participating laboratories. The ampicillin and cefaclor results of the isolates were no better even when a laboratory was able to separate the control strains. Cefaclor results were unreliable because of poor disk diffusion-MIC correspondence and incoherent breakpoint references. Interlaboratory variation of the zone diameters caused false intermediate results of cefuroxime-susceptible strains. When ampicillin, cefaclor and cefuroxime were tested, the discrimination of laboratories using disks and tablets was equal, whereas the laboratories using paper disks were better able to detect trimethoprim-sulfa resistance.
Gusberti, Michele; Klemm, Urs; Meier, Matthias S; Maurhofer, Monika; Hunger-Glaser, Isabel
2015-09-11
Fire blight (FB), caused by Erwinia amylovora, is one of the most important pome fruit pathogens worldwide. To control this devastating disease, various chemical and biological treatments are commonly applied in Switzerland, but they fail to keep the infection at an acceptable level in years of heavy disease pressure. The Swiss authorities therefore currently allow the controlled use of the antibiotic streptomycin against FB in years that are predicted to have heavy infection periods, but only one treatment per season is permitted. Another strategy for controlling Erwinia is to breed resistant/tolerant apple cultivars. One way of accelerating the breeding process is to obtain resistant cultivars by inserting one or several major resistance genes, using genetic engineering. To date, no study summarizing the impact of different FB control measures on the environment and on human health has been performed. This study consequently aims to compare different disease-control measures (biological control, chemical control, control by antibiotics and by resistant/tolerant apple cultivars obtained through conventional or molecular breeding) applied against E. amylovora, considering different protection goals (protection of human health, environment, agricultural diversity and economic interest), with special emphasis on biosafety aspects. Information on each FB control measure in relation to the specified protection goal was assessed by literature searches and by interviews with experts. Based on our results it can be concluded that the FB control measures currently applied in Switzerland are safe for consumers, workers and the environment. However, there are several gaps in our knowledge of the human health and environmental impacts analyzed: data are missing (1) on long term studies on the efficacy of most of the analyzed FB control measures; (2) on the safety of operators handling streptomycin; (3) on residue analyses of Equisetum plant extract, the copper and aluminum compounds used in apple production; and (4) on the effect of biological and chemical control measures on non-target fauna and flora. These gaps urgently need to be addressed in the near future.
Gusberti, Michele; Klemm, Urs; Meier, Matthias S.; Maurhofer, Monika; Hunger-Glaser, Isabel
2015-01-01
Fire blight (FB), caused by Erwinia amylovora, is one of the most important pome fruit pathogens worldwide. To control this devastating disease, various chemical and biological treatments are commonly applied in Switzerland, but they fail to keep the infection at an acceptable level in years of heavy disease pressure. The Swiss authorities therefore currently allow the controlled use of the antibiotic streptomycin against FB in years that are predicted to have heavy infection periods, but only one treatment per season is permitted. Another strategy for controlling Erwinia is to breed resistant/tolerant apple cultivars. One way of accelerating the breeding process is to obtain resistant cultivars by inserting one or several major resistance genes, using genetic engineering. To date, no study summarizing the impact of different FB control measures on the environment and on human health has been performed. This study consequently aims to compare different disease-control measures (biological control, chemical control, control by antibiotics and by resistant/tolerant apple cultivars obtained through conventional or molecular breeding) applied against E. amylovora, considering different protection goals (protection of human health, environment, agricultural diversity and economic interest), with special emphasis on biosafety aspects. Information on each FB control measure in relation to the specified protection goal was assessed by literature searches and by interviews with experts. Based on our results it can be concluded that the FB control measures currently applied in Switzerland are safe for consumers, workers and the environment. However, there are several gaps in our knowledge of the human health and environmental impacts analyzed: data are missing (1) on long term studies on the efficacy of most of the analyzed FB control measures; (2) on the safety of operators handling streptomycin; (3) on residue analyses of Equisetum plant extract, the copper and aluminum compounds used in apple production; and (4) on the effect of biological and chemical control measures on non-target fauna and flora. These gaps urgently need to be addressed in the near future. PMID:26378562
Fire Resistance Testing of Bulkhead and Deck Penetrations.
1985-10-01
consisted of a steel plate identical to that used in the Class A-0 assembly, but rockwool insulation was applied to the fire side of the steel plate and...penetration samples were then insulated with rockwool batts to form a Class A-60 assembly (Figure 2). Between nine and twenty-eight temperature readings...representative of Class A-O construction. The UL staff secured insulation ( rockwool batts) to the fire side of the steel plates and penetrating items to prepare
27 CFR 555.207 - Construction of type 1 magazines.
Code of Federal Regulations, 2012 CFR
2012-04-01
... Construction of type 1 magazines. A type 1 magazine is a permanent structure: a building, an igloo or “Army-type structure”, a tunnel, or a dugout. It is to be bullet-resistant, fire-resistant, weather-resistant...) Fabricated metal wall construction. Metal wall construction is to consist of sectional sheets of steel or...
27 CFR 555.207 - Construction of type 1 magazines.
Code of Federal Regulations, 2014 CFR
2014-04-01
... Construction of type 1 magazines. A type 1 magazine is a permanent structure: a building, an igloo or “Army-type structure”, a tunnel, or a dugout. It is to be bullet-resistant, fire-resistant, weather-resistant...) Fabricated metal wall construction. Metal wall construction is to consist of sectional sheets of steel or...
27 CFR 555.207 - Construction of type 1 magazines.
Code of Federal Regulations, 2013 CFR
2013-04-01
... Construction of type 1 magazines. A type 1 magazine is a permanent structure: a building, an igloo or “Army-type structure”, a tunnel, or a dugout. It is to be bullet-resistant, fire-resistant, weather-resistant...) Fabricated metal wall construction. Metal wall construction is to consist of sectional sheets of steel or...
NASA Technical Reports Server (NTRS)
Gagliani, J.; Sorathia, U. A. K.; Wilcoxson, A. L.
1977-01-01
Materials were developed to improve aircraft interior materials by modifying existing polymer structures, refining the process parameters, and by the use of mechanical configurations designed to overcome specific deficiencies. The optimization, selection, and fabrication of five fire resistant, low smoke emitting open cell foams are described for five different types of aircraft cabin structures. These include: resilient foams, laminate floor and wall paneling, thermal/acoustical insulation, molded shapes, and coated fabrics. All five have been produced from essentially the same polyimide precursor and have resulted in significant benefits from transfer of technology between the various tasks.
Pressure Vessel with Impact and Fire Resistant Coating and Method of Making Same
NASA Technical Reports Server (NTRS)
DeLay, Thomas K. (Inventor)
2005-01-01
An impact and fire resistant coating laminate is provided which serves as an outer protective coating for a pressure vessel such as a composite overwrapped vessel with a metal lining. The laminate comprises a plurality of fibers (e.g., jute twine or other, stronger fibers) which are wound around the pressure vessel and an epoxy matrix resin for the fibers. The epoxy matrix resin including a plurality of microspheres containing a temperature responsive phase change material which changes phase in response to exposure thereof to a predetermined temperature increase so as to afford increased insulation and hear absorption.
Pressure vessel with impact and fire resistant coating and method of making same
NASA Technical Reports Server (NTRS)
DeLay, Thomas K. (Inventor)
2005-01-01
An impact and fire resistant coating laminate is provided which serves as an outer protective coating for a pressure vessel such as a composite overwrapped vessel with a metal lining. The laminate comprises a plurality of fibers (e.g., jute twine or other, stronger fibers) which are wound around the pressure vessel and an epoxy matrix resin for the fibers. The epoxy matrix resin including a plurality of microspheres containing a temperature responsive phase change material which changes phase in response to exposure thereof to a predetermined temperature increase so as to afford increased insulation and heat absorption.
Fire-resistant phosphorus containing polyimides and copolyimides
NASA Technical Reports Server (NTRS)
Mikroyannidis, J. A. (Inventor)
1985-01-01
Phosphorus-containing polyimides and copolyimides are synthesized in a two-step polycondensation reaction from 1- (diorganooxyphosphonl)methly 2,4- and 2,6-diaminobenzenes and tetracarboxylic anhydride. The diorgano position of the diorganooxyphosphonyl group includes alkyl, such as ethyl, substituted alkyl, such as 2-chloroethyl, and aryl such as phenyl. The tetracarboxylic anhydries include compounds such as pyrometallitic dianhydride and benzophenone tetracarboxylic dianhydride. The glass transition temperature (Tg) of the polyimides is reduced by incorporation of the (dialkoxyphosphonyl)methyl groups. The phosphorus-containing copolyimides show a considerably higher degree of fire-resistance as compared to that of the corresponding common polyimides.
Research on Fire-Resistant Diesel Fuel.
1981-12-01
1[ >1 1? 1F RESEARCH ON FIRE-RESISTANT DIESEL FUEL INTERIM REPORT AFLRL No. 145 By W.D. Weatherford, Jr. G.E. Fodor M.D. Kanakia D.W. Naegeli B.R...GRANT NUMBER(S) W.D. Weatherford, Jr., G.E. Fodor, DAAK7O-80-C-OOO1 M.D. Kanakia, D.W. Naegeli , B.R. Wright (AFLRL) DAAK7O-82-C-OOO1 andF.W...Filters in Fuel Systems of U.S. Army Vehicles I:I , i , , , =- 111 REFERENCES 1. Weatherford, W.D., Jr. Fodor, G.E., Naegeli , D.W., Owens, E.C., Wright
Fire safety in the operating room.
Rinder, Christine Stowe
2008-12-01
Elimination of flammable anesthetic gases has had little effect on operating-room fires except to change their etiology. Electrocautery and lasers, in an oxygen-enriched environment, can ignite even the most fire-resistant materials, including the patient, and the fire triad possibilities in the operating room are nearly limitless. This review will: identify operating room contents capable of acting as ignition/oxidizer/fuel sources, highlight operating room items that are uniquely potent fire triad contributors, and operating room identify settings where fire risk is enhanced by proximity of triad components in time or space. Anesthesiologists are cognizant of the risk of airway surgery fires due to laser ignition of the endotracheal tube and/or its contents. Recently, however, head/neck surgery under monitored anesthesia care has emerged as a high-risk setting for operating room fires; burn injuries represent 20% of monitored anesthesia care-related malpractice claims, 95% of which involved head/neck surgery. Operating room fires are infrequent but catastrophic. Operating room fire prevention depends on: (a)understanding how fire triad elements interact to create a fire, (b) recognizing how standard operating-room equipment, materials, and supplemental oxygen can become one of those elements, and (c) vigilance for circumstances that bring fire triad elements into close proximity.
46 CFR 154.467 - Submission of insulation information.
Code of Federal Regulations, 2011 CFR
2011-10-01
... conductivity. (m) Resistance to vibrations. (n) Resistance to fire and flame spread. (o) The manufacturing and... (5) Quality control. [CGD 74-289, 44 FR 26009, May 3, 1979, as amended by CGD 82-063b, 48 FR 4782...
46 CFR 154.467 - Submission of insulation information.
Code of Federal Regulations, 2013 CFR
2013-10-01
... conductivity. (m) Resistance to vibrations. (n) Resistance to fire and flame spread. (o) The manufacturing and... (5) Quality control. [CGD 74-289, 44 FR 26009, May 3, 1979, as amended by CGD 82-063b, 48 FR 4782...
46 CFR 154.467 - Submission of insulation information.
Code of Federal Regulations, 2014 CFR
2014-10-01
... conductivity. (m) Resistance to vibrations. (n) Resistance to fire and flame spread. (o) The manufacturing and... (5) Quality control. [CGD 74-289, 44 FR 26009, May 3, 1979, as amended by CGD 82-063b, 48 FR 4782...
46 CFR 154.467 - Submission of insulation information.
Code of Federal Regulations, 2012 CFR
2012-10-01
... conductivity. (m) Resistance to vibrations. (n) Resistance to fire and flame spread. (o) The manufacturing and... (5) Quality control. [CGD 74-289, 44 FR 26009, May 3, 1979, as amended by CGD 82-063b, 48 FR 4782...
Heat resistant soy adhesives for structural wood products
Christopher G. Hunt; Charles Frihart; Jane O' Dell
2009-01-01
Because load-bearing bonded wood assemblies must support the structure during a fire, the limited softening and depolymerization of biobased polymers at elevated temperatures should be an advantage of biobased adhesives compared to fossil fuel-based adhesives. Because load-bearing bonded wood assemblies must support the structure during a fire, the limited softening...
30 CFR 56.4531 - Flammable or combustible liquid storage buildings or rooms.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and Control Installation/construction/maintenance § 56.4531 Flammable or...) In addition, the buildings or rooms shall be— (1) Constructed to meet a fire resistance rating of at...
Ambient curing fire resistant foams
NASA Technical Reports Server (NTRS)
Hamermesh, C. L.; Hogenson, P. A.; Tung, C. Y.; Sawko, P. M.; Riccitiello, S. R.
1979-01-01
The feasibility of development of an ambient curing foam is described. The thermal stability and flame spread index of the foams were found to be comparable to those of the high-temperature cured polyimide foams by Monsanto two-foot tunnel test and NASA T-3 Fire test. Adaptation of the material to spray in place applications is described
2000-03-30
KENNEDY SPACE CENTER, FLA. -- A NASA helicopter lifts a high-impact-resistant flexible plastic bucket filled with water. The container will be used for fire protection on property and buildings at Kennedy Space Center.. Known as the "Bambi" bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.
2000-03-30
KENNEDY SPACE CENTER, FLA. -- A NASA helicopter lifts a high-impact-resistant flexible plastic bucket that will be used for fire protection on property and buildings at Kennedy Space Center. Known as the "Bambi" bucket, the 324-gallon container will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area
2000-03-30
KENNEDY SPACE CENTER, FLA. -- A NASA helicopter lifts a high-impact-resistant flexible plastic bucket that will be used for fire protection on property and buildings at Kennedy Space Center. Known as the "Bambi" bucket, the 324-gallon container will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area
2000-03-30
KENNEDY SPACE CENTER, FLA. -- A NASA helicopter lifts a high-impact-resistant flexible plastic bucket filled with water. The container will be used for fire protection on property and buildings at Kennedy Space Center.. Known as the "Bambi" bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.
Resistance to invasion and resilience to fire in desert shrublands of North America
Matthew L. Brooks; Jeanne C. Chambers
2011-01-01
Settlement by Anglo-Americans in the desert shrublands of North America resulted in the introduction and subsequent invasion of multiple nonnative grass species. These invasions have altered presettlement fire regimes, resulted in conversion of native perennial shrublands to nonnative annual grasslands, and placed many native desert species at risk. Effective...
46 CFR 164.008-7 - Procedure for approval.
Code of Federal Regulations, 2013 CFR
2013-10-01
... conducted at some laboratory other than the National Bureau of Standards, this information shall be supplied... fire resistance and integrity test will be given at this time together with the estimated cost of the... manufacturer shall submit the samples required by paragraph (c)(1) of this section to the Fire Research Section...
46 CFR 164.008-7 - Procedure for approval.
Code of Federal Regulations, 2010 CFR
2010-10-01
... conducted at some laboratory other than the National Bureau of Standards, this information shall be supplied... fire resistance and integrity test will be given at this time together with the estimated cost of the... manufacturer shall submit the samples required by paragraph (c)(1) of this section to the Fire Research Section...
46 CFR 164.008-7 - Procedure for approval.
Code of Federal Regulations, 2014 CFR
2014-10-01
... conducted at some laboratory other than the National Bureau of Standards, this information shall be supplied... fire resistance and integrity test will be given at this time together with the estimated cost of the... manufacturer shall submit the samples required by paragraph (c)(1) of this section to the Fire Research Section...
46 CFR 164.008-7 - Procedure for approval.
Code of Federal Regulations, 2011 CFR
2011-10-01
... conducted at some laboratory other than the National Bureau of Standards, this information shall be supplied... fire resistance and integrity test will be given at this time together with the estimated cost of the... manufacturer shall submit the samples required by paragraph (c)(1) of this section to the Fire Research Section...
46 CFR 164.008-7 - Procedure for approval.
Code of Federal Regulations, 2012 CFR
2012-10-01
... conducted at some laboratory other than the National Bureau of Standards, this information shall be supplied... fire resistance and integrity test will be given at this time together with the estimated cost of the... manufacturer shall submit the samples required by paragraph (c)(1) of this section to the Fire Research Section...
Flexible fire retardant polyisocyanate modified neoprene foam. [for thermal protective devices
NASA Technical Reports Server (NTRS)
Parker, J. A.; Riccitiello, S. R. (Inventor)
1973-01-01
Lightweight, fire resistant foams have been developed through the modification of conventional neoprene-isocyanate foams by the addition of an alkyl halide polymer. Extensive tests have shown that the modified/neoprene-isocyanate foams are much superior in heat protection properties than the foams heretofore employed both for ballistic and ablative purposes.
49 CFR 178.358-2 - Materials of construction and other requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., Rev. 1. (c) Support and pressure pads for the inner liner must be of neoprene, sponge rubber, or equivalent. (d) Fire-retardant (intumescent) paint must be applied to any wood blocking which is located at... Materials of construction and other requirements. (a) Phenolic foam insulation must be fire resistant and...
49 CFR 178.358-2 - Materials of construction and other requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., Rev. 1. (c) Support and pressure pads for the inner liner must be of neoprene, sponge rubber, or equivalent. (d) Fire-retardant (intumescent) paint must be applied to any wood blocking which is located at... Materials of construction and other requirements. (a) Phenolic foam insulation must be fire resistant and...
NASA Astrophysics Data System (ADS)
Zybina, Olga; Gravit, Marina; Stein, Yelena
2017-10-01
In work ability of the intercalated graphite entered into the fireproof intumescent compositions to act as catalytically active additive raising operational characteristics of the classical distending coverings intended for fire protection of building constructions. It is established that thermal expanded graphite, as well as nano-additives, increase frequency rate, durability, elasticity, density and uniformity of a coke layer of a fireproof covering for increase of fire resistance of a building construction.
Robust Low Cost Liquid Rocket Combustion Chamber by Advanced Vacuum Plasma Process
NASA Technical Reports Server (NTRS)
Holmes, Richard; Elam, Sandra; Ellis, David L.; McKechnie, Timothy; Hickman, Robert; Rose, M. Franklin (Technical Monitor)
2001-01-01
Next-generation, regeneratively cooled rocket engines will require materials that can withstand high temperatures while retaining high thermal conductivity. Fabrication techniques must be cost efficient so that engine components can be manufactured within the constraints of shrinking budgets. Three technologies have been combined to produce an advanced liquid rocket engine combustion chamber at NASA-Marshall Space Flight Center (MSFC) using relatively low-cost, vacuum-plasma-spray (VPS) techniques. Copper alloy NARloy-Z was replaced with a new high performance Cu-8Cr-4Nb alloy developed by NASA-Glenn Research Center (GRC), which possesses excellent high-temperature strength, creep resistance, and low cycle fatigue behavior combined with exceptional thermal stability. Functional gradient technology, developed building composite cartridges for space furnaces was incorporated to add oxidation resistant and thermal barrier coatings as an integral part of the hot wall of the liner during the VPS process. NiCrAlY, utilized to produce durable protective coating for the space shuttle high pressure fuel turbopump (BPFTP) turbine blades, was used as the functional gradient material coating (FGM). The FGM not only serves as a protection from oxidation or blanching, the main cause of engine failure, but also serves as a thermal barrier because of its lower thermal conductivity, reducing the temperature of the combustion liner 200 F, from 1000 F to 800 F producing longer life. The objective of this program was to develop and demonstrate the technology to fabricate high-performance, robust, inexpensive combustion chambers for advanced propulsion systems (such as Lockheed-Martin's VentureStar and NASA's Reusable Launch Vehicle, RLV) using the low-cost VPS process. VPS formed combustion chamber test articles have been formed with the FGM hot wall built in and hot fire tested, demonstrating for the first time a coating that will remain intact through the hot firing test, and with no apparent wear. Material physical properties and the hot firing tests are reviewed.
Jiang, Long; Li, Yu
2016-04-15
In this study, the properties of AhR binding affinity, bio-concentration factor, half-life and vapor pressure were selected as the typical indicators of biological toxicity, bio-concentration, persistence and atmospheric long-range transport potential for polybrominated diphenyl ethers (PBDEs), respectively. A three-dimensional pharmacophore modeling assistant with a full factor experimental design for each property was used to reveal the significant pharmacophore features and the substituent effects to obtain reasonable modified schemes for the selected target PBDEs. Finally, the performances of the persistent organic pollutant (POP) properties, the synthesis feasibility and the fire resistance of the modified compounds were evaluated. The most influential pharmacophore feature for all POP properties was the hydrophobic group, especially the vinyl and propyl groups. Modified compounds with two additional hydrophobic groups exhibited a better regulatory performance. The average reduction in the proportions of the four POP properties for the modified compounds (except for 3-phenyl-BDE-15) was 70.60%, 52.44%, 47.04% and 70.88%. In addition, the energy and the C-Br bond dissociation enthalpy of the four typical PBDEs were higher than those of the modified compounds (except for 3-phenyl-BDE-15), indicating the synthesis feasibility and the lower energy barrier of the modified compounds to release Br free radicals to provide fire resistance. Copyright © 2015 Elsevier B.V. All rights reserved.
Application of synthetic fire-resistant oils in oil systems of turbine equipment for NPPs
NASA Astrophysics Data System (ADS)
Galimova, L. A.
2017-10-01
Results of the investigation of the synthetic fire-resistant turbine oil Fyrquel-L state in oil systems of turbosets under their operation in the equipment and oil supply facilities of nuclear power plants (NPPs) are presented. On the basis of the analysis of the operating experience, it is established that, for reliable and safe operation of the turbine equipment, at which oil systems synthetic fire-resistant oils on the phosphoric acid esters basis are used, special attention should be paid to two main factors, namely, both the guarantee of the normalized oil water content under the operation and storage and temperature regime of the operation. Methods of the acid number maintenance and reduction are shown. Results of the analysis and investigation of influence of temperature and of the variation of the qualitative state of the synthetic fair-resistant oil on its water content are reported. It is shown that the fire-resistant turbine oils are characterized by high hydrophilicity, and, in distinction to the mineral turbine oils, are capable to contain a significant amount of dissolved water, which is not extracted under the use of separation technologies. It is shown that the more degradation products are contained in oil and higher acid number, the more amount of dissolved water it is capable to retain. It is demonstrated that the organization of chemical control of the total water content of fireresistant oils with the use of the coulometric method is an important element to support the reliable operation of oil systems. It is recommended to use automatic controls of water content for organization of daily monitoring of oil state in the oil system. Recommendations and measures for improvement of oil operation on the NPP, the water content control, the use of oil cleaning plants, and the oil transfer for storage during repair works are developed.
Kamber, Tim; Buchmann, Jan P; Pothier, Joël F; Smits, Theo H M; Wicker, Thomas; Duffy, Brion
2016-02-17
The molecular basis of resistance and susceptibility of host plants to fire blight, a major disease threat to pome fruit production globally, is largely unknown. RNA-sequencing data from challenged and mock-inoculated flowers were analyzed to assess the susceptible response of apple to the fire blight pathogen Erwinia amylovora. In presence of the pathogen 1,080 transcripts were differentially expressed at 48 h post inoculation. These included putative disease resistance, stress, pathogen related, general metabolic, and phytohormone related genes. Reads, mapped to regions on the apple genome where no genes were assigned, were used to identify potential novel genes and open reading frames. To identify transcripts specifically expressed in response to E. amylovora, RT-PCRs were conducted and compared to the expression patterns of the fire blight biocontrol agent Pantoea vagans strain C9-1, another apple pathogen Pseudomonas syringae pv. papulans, and mock inoculated apple flowers. This led to the identification of a peroxidase superfamily gene that was lower expressed in response to E. amylovora suggesting a potential role in the susceptibility response. Overall, this study provides the first transcriptional profile by RNA-seq of the host plant during fire blight disease and insights into the response of susceptible apple plants to E. amylovora.
Kamber, Tim; Buchmann, Jan P.; Pothier, Joël F.; Smits, Theo H. M.; Wicker, Thomas; Duffy, Brion
2016-01-01
The molecular basis of resistance and susceptibility of host plants to fire blight, a major disease threat to pome fruit production globally, is largely unknown. RNA-sequencing data from challenged and mock-inoculated flowers were analyzed to assess the susceptible response of apple to the fire blight pathogen Erwinia amylovora. In presence of the pathogen 1,080 transcripts were differentially expressed at 48 h post inoculation. These included putative disease resistance, stress, pathogen related, general metabolic, and phytohormone related genes. Reads, mapped to regions on the apple genome where no genes were assigned, were used to identify potential novel genes and open reading frames. To identify transcripts specifically expressed in response to E. amylovora, RT-PCRs were conducted and compared to the expression patterns of the fire blight biocontrol agent Pantoea vagans strain C9-1, another apple pathogen Pseudomonas syringae pv. papulans, and mock inoculated apple flowers. This led to the identification of a peroxidase superfamily gene that was lower expressed in response to E. amylovora suggesting a potential role in the susceptibility response. Overall, this study provides the first transcriptional profile by RNA-seq of the host plant during fire blight disease and insights into the response of susceptible apple plants to E. amylovora. PMID:26883568
NASA Astrophysics Data System (ADS)
Giancaspro, James William
Lightweight composites and structural sandwich panels are commonly used in marine and aerospace applications. Using carbon, glass, and a host of other high strength fiber types, a broad range of laminate composites and sandwich panels can be developed. Hybrid composites can be constructed by laminating multiple layers of varying fiber types while sandwich panels are manufactured by laminating rigid fiber facings onto a lightweight core. However, the lack of fire resistance of the polymers used for the fabrication remains a very important problem. The research presented in this dissertation deals with an inorganic matrix (Geopolymer) that can be used to manufacture laminate composites and sandwich panels that are resistant up to 1000°C. This dissertation deals with the influence of fiber type on the mechanical behavior and the fire response of hybrid composites and sandwich structures manufactured using this resin. The results are categorized into the following distinct studies. (i) High strength carbon fibers were combined with low cost E-glass fibers to obtain hybrid laminate composites that are both economical and strong. The E-glass fabrics were used as a core while the carbon fibers were placed on the tension face and on both tension and compression faces. (ii) Structural sandwich beams were developed by laminating various types of reinforcement onto the tension and compression faces of balsa wood cores. The flexural behavior of the beams was then analyzed and compared to beams reinforced with organic composite. The effect of core density was evaluated using oak beams reinforced with inorganic composite. (iii) To measure the fire response, balsa wood sandwich panels were manufactured using a thin layer of a fire-resistant paste to serve for fire protection. Seventeen sandwich panels were fabricated and tested to measure the heat release rates and smoke-generating characteristics. The results indicate that Geopolymer can be effectively used to fabricate both high strength composite plates and sandwich panels. A 2 mm thick coating of fireproofing on balsa wood is sufficient to satisfy FAA fire requirements.
Sterczala, Adam J; Miller, Jonathan D; Trevino, Michael A; Dimmick, Hannah L; Herda, Trent J
2018-02-26
Previous investigations report no changes in motor unit (MU) firing rates during submaximal contractions following resistance training. These investigations did not account for MU recruitment or examine firing rates as a function of recruitment threshold (REC).Therefore, MU recruitment and firing rates in chronically resistance trained (RT) and physically active controls (CON) were examined. Surface electromyography signals were collected from the first dorsal interosseous (FDI) during isometric muscle actions at 40% and 70% maximal voluntary contraction (MVC). For each MU, force at REC, mean firing rate (MFR) during the steady force, and MU action potential amplitude (MUAPAMP) were analyzed. For each individual and contraction, the MFRs were linearly regressed against REC, whereas, exponential models were applied to the MFR vs. MUAPAMP and MUAPAMP vs. REC relationships with the y-intercepts and slopes (linear) and A and B terms (exponential) calculated. For the 40% MVC, the RT group had less negative slopes (p=0.001) and lower y-intercepts (p=0.006) of the MFR vs. REC relationships and lower B terms (p=0.011) of the MUAPAMP vs. REC relationships. There were no differences in either relationship between groups for the 70% MVC. During the 40% MVC, the RT had a smaller range of MFRs and MUAPAMPS in comparison to the CON, likely due to reduced MU recruitment. The RT had lower MFRs and recruitment during the 40% MVC that may indicate a leftward shift in the force-frequency relationship, and thus require less excitation to the motoneuron pool to match the same relative force.
A Home Ignition Assessment Model Applied to Structures in the Wildland-Urban Interface
DOE Office of Scientific and Technical Information (OSTI.GOV)
Biswas, Kaushik; Werth, David; Gupta, Narendra
2013-01-01
The issue of exterior fire threat to buildings, from either wildfires in the wildland-urban interface or neighboring structure fires, is critically important. To address this, theWildfire Ignition Resistant Home Design (WIRHD) program was initiated. The WIRHD program developed a tool, theWildFIREWizard, that will allow homeowners to estimate the external fire threat to their homes based on specific features and characteristics of the homes and yards. The software then makes recommendations to reduce the threat. The inputs include the structural and material features of the home and information about any ignition sources or flammable objects in its immediate vicinity, known asmore » the home ignition zone. The tool comprises an ignition assessment model that performs explicit calculations of the radiant and convective heating of the building envelope from the potential ignition sources. This article describes a series of material ignition and flammability tests that were performed to calibrate and/or validate the ignition assessment model. The tests involved exposing test walls with different external siding types to radiant heating and/or direct flame contact.The responses of the test walls were used to determine the conditions leading to melting, ignition, or any other mode of failure of the walls. Temperature data were used to verify the model predictions of temperature rises and ignition times of the test walls.« less
Antoine-Santoni, Thierry; Santucci, Jean-François; de Gentili, Emmanuelle; Silvani, Xavier; Morandini, Frederic
2009-01-01
The paper deals with a Wireless Sensor Network (WSN) as a reliable solution for capturing the kinematics of a fire front spreading over a fuel bed. To provide reliable information in fire studies and support fire fighting strategies, a Wireless Sensor Network must be able to perform three sequential actions: 1) sensing thermal data in the open as the gas temperature; 2) detecting a fire i.e., the spatial position of a flame; 3) tracking the fire spread during its spatial and temporal evolution. One of the great challenges in performing fire front tracking with a WSN is to avoid the destruction of motes by the fire. This paper therefore shows the performance of Wireless Sensor Network when the motes are protected with a thermal insulation dedicated to track a fire spreading across vegetative fuels on a field scale. The resulting experimental WSN is then used in series of wildfire experiments performed in the open in vegetation areas ranging in size from 50 to 1,000 m2. PMID:22454563
Antoine-Santoni, Thierry; Santucci, Jean-François; de Gentili, Emmanuelle; Silvani, Xavier; Morandini, Frederic
2009-01-01
The paper deals with a Wireless Sensor Network (WSN) as a reliable solution for capturing the kinematics of a fire front spreading over a fuel bed. To provide reliable information in fire studies and support fire fighting strategies, a Wireless Sensor Network must be able to perform three sequential actions: 1) sensing thermal data in the open as the gas temperature; 2) detecting a fire i.e., the spatial position of a flame; 3) tracking the fire spread during its spatial and temporal evolution. One of the great challenges in performing fire front tracking with a WSN is to avoid the destruction of motes by the fire. This paper therefore shows the performance of Wireless Sensor Network when the motes are protected with a thermal insulation dedicated to track a fire spreading across vegetative fuels on a field scale. The resulting experimental WSN is then used in series of wildfire experiments performed in the open in vegetation areas ranging in size from 50 to 1,000 m(2).
Induction of antimicrobial 3-deoxyflavonoids in pome fruit trees controls fire blight.
Halbwirth, Heidrun; Fischer, Thilo C; Roemmelt, Susanne; Spinelli, Francesco; Schlangen, Karin; Peterek, Silke; Sabatini, Emidio; Messina, Christian; Speakman, John-Bryan; Andreotti, Carlo; Rademacher, Wilhelm; Bazzi, Carlo; Costa, Guglielmo; Treutter, Dieter; Forkmann, Gert; Stich, Karl
2003-01-01
Fire blight, a devastating bacterial disease in pome fruits, causes severe economic losses worldwide. Hitherto, an effective control could only be achieved by using antibiotics, but this implies potential risks for human health, livestock and environment. A new approach allows transient inhibition of a step in the flavonoid pathway, thereby inducing the formation of a novel antimicrobial 3-deoxyflavonoid controlling fire blight in apple and pear leaves. This compound is closely related to natural phytoalexins in sorghum. The approach does not only provide a safe method to control fire blight: Resistance against different pathogens is also induced in other crop plants.
Limitations imposed on fire PRA methods as the result of incomplete and uncertain fire event data.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nowlen, Steven Patrick; Hyslop, J. S.
2010-04-01
Fire probabilistic risk assessment (PRA) methods utilize data and insights gained from actual fire events in a variety of ways. For example, fire occurrence frequencies, manual fire fighting effectiveness and timing, and the distribution of fire events by fire source and plant location are all based directly on the historical experience base. Other factors are either derived indirectly or supported qualitatively based on insights from the event data. These factors include the general nature and intensity of plant fires, insights into operator performance, and insights into fire growth and damage behaviors. This paper will discuss the potential methodology improvements thatmore » could be realized if more complete fire event reporting information were available. Areas that could benefit from more complete event reporting that will be discussed in the paper include fire event frequency analysis, analysis of fire detection and suppression system performance including incipient detection systems, analysis of manual fire fighting performance, treatment of fire growth from incipient stages to fully-involved fires, operator response to fire events, the impact of smoke on plant operations and equipment, and the impact of fire-induced cable failures on plant electrical circuits.« less
New Screening Test Developed for the Blanching Resistance of Copper Alloys
NASA Technical Reports Server (NTRS)
Thomas-Ogbuji, Linus U.
2004-01-01
NASA's extensive efforts towards more efficient, safer, and more affordable space transportation include the development of new thrust-cell liner materials with improved capabilities and longer lives. For rocket engines fueled with liquid hydrogen, an important metric of liner performance is resistance to blanching, a phenomenon of localized wastage by cycles of oxidation-reduction due to local imbalance in the oxygen-fuel ratio. The current liner of the Space Shuttle Main Engine combustion chamber, a Cu-3Ag-0.5Zr alloy (NARloy-Z) is degraded in service by blanching. Heretofore, evaluating a liner material for blanching resistance involved elaborate and expensive hot-fire tests performed on rocket test stands. To simplify that evaluation, researchers at the NASA Glenn Research Center developed a screening test that uses simple, in situ oxidation-reduction cycling in a thermogravimetric analyzer (TGA). The principle behind this test is that resistance to oxidation or to the reduction of oxide, or both, implies resistance to blanching. Using this test as a preliminary tool to screen alloys for blanching resistance can improve reliability and save time and money. In this test a small polished coupon is hung in a TGA furnace at the desired (service) temperature. Oxidizing and reducing gases are introduced cyclically, in programmed amounts. Cycle durations are chosen by calibration, such that all copper oxides formed by oxidation are fully reduced in the next reduction interval. The sample weight is continuously acquired by the TGA as usual.
Riisager, Anders; Duehmke, Rudy; Nielsen, Ole Bækgaard; Huang, Christopher L; Pedersen, Thomas Holm
2014-10-15
Recent studies in rat muscle fibres show that repetitive firing of action potentials causes changes in fibre resting membrane conductance (Gm) that reflect regulation of ClC-1 Cl(-) and KATP K(+) ion channels. Methodologically, these findings were obtained by inserting two microelectrodes at close proximity in the same fibres enabling measurements of fibre input resistance (Rin) in between action potential trains. Since the fibre length constant (λ) could not be determined, however, the calculation of Gm relied on the assumptions that the specific cytosolic resistivity (Ri) and muscle fibre volume remained constant during the repeated action potential firing. Here we present a three-microelectrode technique that enables determinations of multiple cable parameters in action potential-firing fibres including Rin and λ as well as waveform and conduction velocities of fully propagating action potentials. It is shown that in both rat and mouse extensor digitorum longus (EDL) fibres, action potential firing leads to substantial changes in both muscle fibre volume and Ri. The analysis also showed, however, that regardless of these changes, rat and mouse EDL fibres both exhibited initial decreases in Gm that were eventually followed by a ∼3-fold, fully reversible increase in Gm after the firing of 1450-1800 action potentials. Using this three-electrode method we further show that the latter rise in Gm was closely associated with excitation failures and loss of action potential signal above -20 mV. © 2014 The Authors. The Journal of Physiology © 2014 The Physiological Society.
Riisager, Anders; Duehmke, Rudy; Nielsen, Ole Bækgaard; Huang, Christopher L; Pedersen, Thomas Holm
2014-01-01
Recent studies in rat muscle fibres show that repetitive firing of action potentials causes changes in fibre resting membrane conductance (Gm) that reflect regulation of ClC-1 Cl− and KATP K+ ion channels. Methodologically, these findings were obtained by inserting two microelectrodes at close proximity in the same fibres enabling measurements of fibre input resistance (Rin) in between action potential trains. Since the fibre length constant (λ) could not be determined, however, the calculation of Gm relied on the assumptions that the specific cytosolic resistivity (Ri) and muscle fibre volume remained constant during the repeated action potential firing. Here we present a three-microelectrode technique that enables determinations of multiple cable parameters in action potential-firing fibres including Rin and λ as well as waveform and conduction velocities of fully propagating action potentials. It is shown that in both rat and mouse extensor digitorum longus (EDL) fibres, action potential firing leads to substantial changes in both muscle fibre volume and Ri. The analysis also showed, however, that regardless of these changes, rat and mouse EDL fibres both exhibited initial decreases in Gm that were eventually followed by a ∼3-fold, fully reversible increase in Gm after the firing of 1450–1800 action potentials. Using this three-electrode method we further show that the latter rise in Gm was closely associated with excitation failures and loss of action potential signal above −20 mV. PMID:25128573
NASA Technical Reports Server (NTRS)
Supkis, D. E.
1975-01-01
Selected fire-retardant materials for possible application to commercial aircraft are described. The results of flammability screening tests and information on the physical and chemical properties of both original and newly installed materials after extended use are presented in tabular form, with emphasis on wear properties, strength, puncture and tear resistances, and cleanability.
A Feasibility Assessment of 6LoWPAN for Secure Communications in the U.S. Army
2016-06-01
22 1. Obstacles .......................................................................................22 2. Resistance against...35 Table 6. An Example of a Pre-formatted Call for Fire (CFF) Exchange and Expected Byte...friendly forces in a dismounted operation often occurs through line of sight (LOS) or verbal passing of information within a small fire -team or squad sub
Examination of a Wear-Reducing Muzzle Device
2013-08-01
resistant material attached to the muzzle end of the gun tube. The bore diameter of the device is slightly less than the bore diameter of the gun. The...3 Figure 3. Weapon and universal bearing slide used for firings ...small caliber round of ammunition. ..........21 v List of Tables Table 1. Firing test matrix for phase 1
Paul F. Hessburg; Thomas A. Spies; David A. Perry; Carl N. Skinner; Alan H. Taylor; Peter M. Brown; Scott L. Stephens; Andrew J. Larson; Derek J. Churchill; Nicholas A. Povak; Peter H. Singleton; Brenda McComb; William J. Zielinski; Brandon M. Collins; R. Brion Salter; John J. Keane; Jerry F. Franklin; Greg Riegel
2016-01-01
Increasingly, objectives for forests with moderate- or mixed-severity fire regimes are to restore successionally diverse landscapes that are resistant and resilient to current and future stressors. Maintaining native species and characteristic processes requires this successional diversity, but methods to achieve it are poorly explained in the literature. In the Inland...
2000-03-30
KENNEDY SPACE CENTER, FLA. -- A NASA helicopter hovers over the water while a high-impact-resistant flexible plastic bucket fills. The 324-gallon container will be used for fire protection on property and buildings at Kennedy Space Center. Known as the "Bambi" bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area
2000-03-30
KENNEDY SPACE CENTER, FLA. -- A NASA helicopter releases the contents of the high-impact-resistant flexible plastic bucket it holds. The 324-gallon container will be used for fire protection on property and buildings at Kennedy Space Center. Known as the "Bambi" bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.
2000-03-30
KENNEDY SPACE CENTER, FLA. -- A NASA helicopter releases the contents of the high-impact-resistant flexible plastic bucket it holds. The 324-gallon container will be used for fire protection on property and buildings at Kennedy Space Center. Known as the "Bambi" bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.
2000-03-30
KENNEDY SPACE CENTER, FLA. -- Workers attach a high-impact-resistant flexible plastic bucket to a NASA helicopter. Holding 324 gallons of water, it will be used for fire protection on property and buildings at Kennedy Space Center. Known as the "Bambi" bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.
2000-03-30
KENNEDY SPACE CENTER, FLA. -- A NASA helicopter hovers over the water while a high-impact-resistant flexible plastic bucket fills. The 324-gallon container will be used for fire protection on property and buildings at Kennedy Space Center. Known as the "Bambi" bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area
2000-03-30
KENNEDY SPACE CENTER, FLA. -- Workers attach a high-impact-resistant flexible plastic bucket to a NASA helicopter. Holding 324 gallons of water, it will be used for fire protection on property and buildings at Kennedy Space Center. Known as the "Bambi" bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-30
..., electrical resistance, and fire extinguishing including cooking oil fires for light duty and heavy duty... operation and will not create a hazardous condition even with cooking oil in the cooktop. Discussion of... the cooktop is unattended, which would prohibit a single person from cooking on the cooktop and...
David Butry; Geoffrey Donovan
2008-01-01
Climate change, increased wildland fuels, and residential development patterns in fire-prone areas all combine to make wildfire risk mitigation an important public policy issue. One approach to wildfire risk mitigation is to encourage homeowners to use fire-resistant building materials and to create defensible spaces around their homes. We develop a theoretical model...
NASA Technical Reports Server (NTRS)
1976-01-01
The development of suitable electrocoatings and subsequent application to nonconductive substrates are discussed. Substrates investigated were plastics or resin-treated materials such as FX-resin (phenolic-type resin) impregnated fiberglass mat, polyphenylene sulfide, polyether sulfone and polyimide-impregnated unidirectional fiberglass. Efforts were aimed at formulating a fire-resistant, low smoke emitting, thermally stable, easily cleaned coating material. The coating is to be used for covering substrate panels, such as aluminum, silicate foam, polymeric structural entities, etc., all of which are applied in the aircraft cabin interior and thus subject to the spillages, scuffing, spotting and the general contaminants which prevail in aircraft passenger compartments.
NASA Technical Reports Server (NTRS)
Hsu, M. T. S.
1976-01-01
The thermochemistry of bismaleimide resins and phenolphthalein polycarbonate was studied. Both materials are fire-resistant polymers and may be suitable for aircraft interiors. The chemical composition of the polymers has been determined by nuclear magnetic resonance and infrared spectroscopy and by elemental analysis. Thermal properties of these polymers have been characterized by thermogravimetric analyses. Qualitative evaluation of the volatile products formed in pyrolysis under oxidative and non-oxidative conditions has been made using infrared spectrometry. The residues after pyrolysis were analyzed by elemental analysis. The thermal stability of composite panel and thermoplastic materials for aircraft interiors was studied by thermogravimetric analyses.
Assessment of relative flammability and thermochemical properties of some thermoplastic materials
NASA Technical Reports Server (NTRS)
Kourtides, D. A.; Parker, J. A.
1977-01-01
Thermomechanical properties, flammability, oxygen index, relative toxicity of pyrolysis effluents, and char yields were studied for 12 advanced polymers which are candidates for use in aircraft interiors as decorative films, compression- and injection-molded parts and thermoplastic parts. Polymers sampled included polyphenylene sulfide, 9,9 bis (4-hydroxyphenol) fluorene polycarbonate-poly (dimethylsiloxane), polyether sulfone, polyvinyl fluoride and polyvinylidene fluoride. Availability of these samples, whether in commercial form or in test quantities, is specified. An estimate of relative fire resistance for the materials was obtained; the five polymers listed above were found to be the most fire resistant of the 12 sampled.
Fire resistant films for aircraft applications
NASA Technical Reports Server (NTRS)
Kourtides, D. A.
1983-01-01
Alternative sandwich panel decorative films were investigated as replacements for the polyvinyl fluoride currently used in aircraft interiors. Candidate films were studied for flammability, smoke emission, toxic gas emission, flame spread, and suitability as a printing surface for the decorative acrylic ink system. Several of the candidate films tested were flame modified polyvinyl fluoride, polyvinylidene fluoride, polyimide, polyamide, polysulfone, polyphenylsulfone, polyethersulfone, polybenzimidazole, polycarbonate, polyparabanic acid, polyphosphazene, polyetheretherketon, and polyester. The films were evaluated as pure films only, films silk-screened with an acrylic ink, and films adhered to a phenolic fiberglass substrate. Films which exhibited the highest fire resistant properties included PEEK polyetheretherketon, Aramid polyamide, and ISO-BPE polyester.
Fighting Fire with Fire: Surgical Options for Patients with Drug-Resistant Epilepsy.
Bayer, Alina D; Blum, Andrew S; Asaad, Wael F; Roth, Julie; Toms, Steven A; Deck, Gina M
2018-03-01
While antiepileptic drugs (AEDs) provide adequate seizure control for most patients with epilepsy, ~30% continue to have seizures despite treatment with two or more AEDs.1 In addition to direct harm from seizures, poor epilepsy control correlates with higher mortality, morbidity, 2, 3 and cost to the healthcare system.4 In the subset of patients with persistent seizures despite medical management, surgical intervention and neuromodulation may be more effective. Primary care physicians and general neurologists should be aware of non-AED treatment options that are standard of care for drug- resistant epilepsy (DRE). [Full article available at http://rimed.org/rimedicaljournal-2018-03.asp].
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-16
... Utility Steam Generating Units and Standards of Performance for Fossil-Fuel-Fired Electric Utility... Performance for Fossil-Fuel-Fired Electric Utility, Industrial-Commercial-Institutional, and Small Industrial... electric utility steam generating units (EGUs) and standards of performance for fossil-fuel-fired electric...
The membrane properties and firing characteristics of rat jaw-elevator motoneurones.
Moore, J; Appenteng, K
1990-01-01
1. We have determined the membrane and firing properties of fifty-six jaw-elevator motoneurones in rats that were anaesthetized with pentobarbitone, paralysed and artificially ventilated. 2. Forty-two neurones were identified as masseter motoneurones and fourteen as masseter synergist motoneurones. The membrane potentials for the sample ranged from -60 to -86 (mean = -68; S.D. = 7.3; n = 56), and spike amplitudes from 50 to 95 mV. The duration of the after-hyperpolarization following antidromic spikes in masseter motoneurones ranged from 15 to 50 ms (mean = 30; S.D. = 12.8) and their amplitudes from 1.0 to 4.5 mV (mean = 2.7; S.D. = 2.2; n = 42). 3. The mean input resistance for the total sample was 2.3 M omega (S.D. = 0.9; n = 56), membrane time constant 3.9 ms (S.D. = 0.9; n = 48) and rheobase 4.2 nA (S.D. = 2.6; n = 56). The distribution of these parameters was independent of membrane potential. We found no significant interrelationships between the membrane properties and one interpretation of this is that our sample may be drawn from a homogenous population of motoneurones. We also suggest that elevator motoneurones may have a lower Rm (specific membrane resistivity) value than cat hindlimb motoneurones because they have a similar range of input resistance values but only half the total surface area. 4. Forty-six out of forty-nine neurones fired repetitively to a depolarizing current pulse at a mean threshold of 1.6 x rheobase. Current-frequency plots were constructed for thirteen neurones and all but one showed a primary and secondary range in the firing of the first interspike interval. The mean slope in the primary range was 31 impulses s-1 nA-1 and 77 impulses s-1 nA-1 for the secondary range. The mean minimal firing frequency for steady firing was 26 impulses s-1 and, in response to an increase of stimulation, the rate increased monotonically with a slope of 11 impulses s-1 nA-1. 5. The dynamic sensitivity of twelve neurones was assessed from their response to ramp waveforms of current of constant amplitude but varying frequencies (0.2-2 Hz). Firing initially increased along a steep slope up to a frequency of between 40 and 60 impulses s-1 and then increased along a much shallower slope. Both the threshold for eliciting firing and the firing at the transition point of the two slopes remained constant with changes in ramp frequency.(ABSTRACT TRUNCATED AT 400 WORDS) PMID:2388148
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-20
... Standards of Performance for Fossil-Fuel-Fired, Electric Utility, Industrial-Commercial-Institutional, and... Fossil fuel-fired electric utility steam generating units. Federal Government 22112 Fossil fuel-fired... 22112 Fossil fuel-fired electric utility steam generating units owned by municipalities. 921150 Fossil...
USDA-ARS?s Scientific Manuscript database
Erwinia amylovora is the causal agent of the fire blight disease in some plants of the Rosaceae family. The nonhost plant Arabidopsis serves as a powerful system to dissect mechanisms of resistance to E. amylovora. Although not yet known to mount gene-for-gene resistance to E. amylovora, we found ...
Fatigue Characterization of Fire Resistant Syntactic Foam Core Material
NASA Astrophysics Data System (ADS)
Hossain, Mohammad Mynul
Eco-Core is a fire resistant material for sandwich structural application; it was developed at NC A&T State University. The Eco-Core is made of very small amount of phenolic resin and large volume of flyash by a syntactic process. The process development, static mechanical and fracture, fire and toxicity safety and water absorption properties and the design of sandwich structural panels with Eco-Core material was established and published in the literature. One of the important properties that is needed for application in transportation vehicles is the fatigue performance under different stress states. Fatigue data are not available even for general syntactic foams. The objective of this research is to investigate the fatigue performance of Eco-Core under three types of stress states, namely, cyclic compression, shear and flexure, then document failure modes, and develop empherical equations for predicting fatigue life of Eco-Core under three stress states. Compression-Compression fatigue was performed directly on Eco-Core cylindrical specimen, whereas shear and flexure fatigue tests were performed using sandwich beam made of E glass-Vinyl Ester face sheet and Eco-Core material. Compression-compression fatigue test study was conducted at two values of stress ratios (R=10 and 5), for the maximum compression stress (sigmamin) range of 60% to 90% of compression strength (sigmac = 19.6 +/- 0.25 MPa) for R=10 and 95% to 80% of compression strength for R=5. The failure modes were characterized by the material compliance change: On-set (2% compliance change), propagation (5%) and ultimate failure (7%). The number of load cycles correspond to each of these three damages were characterized as on-set, propagation and total lives. A similar approach was used in shear and flexure fatigue tests with stress ratio of R=0.1. The fatigue stress-number of load cycles data followed the standard power law equation for all three stress states. The constant of the equation were established for the three stress states and three types of the failure modes. This equation was used to estimate endurance limit (106 cycles) of the material. Like metallic materials, the compression fatigue life of Eco-Core was found to be dependent on the stress range instead of maximum or mean cyclic stress. Furthermore shear and flexural ultimate failure of the core material was found to be due to a combination of shear and tensile stress.
Kempe, Andreas; Neinhuis, Christoph; Lautenschläger, Thea
2018-02-17
The thick and woody shell of the fruit of Adansonia species cannot be explained solely by adaptation to zoochory or hydrochory. Since the trunks of Adansonia possess a thick and fire-resistant bark and wildfires occur regularly in its habitat (savannah), we examined with the African Adanonia digitata and the Australian Adansonia gregorii whether the fruit offers protection against high heat typically experienced in wildfires. Heat-resistance tests were conducted by applying a simple heat test based on known temperature and temperature residence times occurring in savannah fires and complemented by tests to reveal the impact of heat on germination since long-term seed dormancy is known for Adansonia. Germination tests with acid treated and heat treated seeds were performed to establish if heat also increased germination rate as effectively as acid treatments have been found to do. Heat was found to increase germination rate, but not as effectively as treatment with acid, therefore fruits exposed to high temperatures experienced in wildfires may have a better chance of germination than fruits that were not exposed to wildfires. The ability of the investigated fruits to protect seeds from high temperatures suggests that wildfires may have played a role in the evolution of the hard-shell structure typically found in Adansonia.
Comparing the performance of residential fire sprinklers with other life-safety technologies.
Butry, David T
2012-09-01
Residential fire sprinklers have long proven themselves as life-safety technologies to the fire service community. Yet, about 1% of all one- and two-family dwelling fires occur in homes protected by sprinklers. It has been argued that measured sprinkler performance has ignored factors confounding the relationship between sprinkler use and performance. In this analysis, sprinkler performance is measured by comparing 'like' structure fires, while conditioning on smoke detection technology and neighborhood housing and socioeconomic conditions, using propensity score matching. Results show that residential fire sprinklers protect occupant and firefighter health and safety, and are comparable to other life-safety technologies. Published by Elsevier Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aziz, Hammad, E-mail: engr.hammad.aziz03@gmail.com; Ahmad, Faiz, E-mail: faizahmad@petronas.com.my; Yusoff, P. S. M. Megat
Intumescent fire retardant coating (IFRC) is a passive fire protection system which swells upon heating to form expanded multi-cellular char layer that protects the substrate from fire. In this research work, IFRC’s were developed using different flame retardants such as ammonium polyphosphate, expandable graphite, melamine and boric acid. These flame retardants were bound together with the help of epoxy binder and cured together using curing agent. IFRC was then reinforced with nano magnesium oxide and nano alumina as inorganic fillers to study their effect towards fire performance, microstructure and thermal degradation. Small scale fire test was conducted to investigate themore » thermal insulation of coating whereas fire performance was calculated using thermal margin value. Field emission scanning electron microscopy was used to examine the microstructure of char obtained after fire test. Thermogravimetric analysis was conducted to investigate the residual weight of coating. Results showed that the performance of the coating was enhanced by reinforcement with nano size fillers as compared to non-filler based coating. Comparing both nano size magnesium oxide and nano size alumina; nano size alumina gave better fire performance with improved microstructure of char and high residual weight.« less
NASA Astrophysics Data System (ADS)
Aziz, Hammad; Ahmad, Faiz; Yusoff, P. S. M. Megat; Zia-ul-Mustafa, M.
2015-07-01
Intumescent fire retardant coating (IFRC) is a passive fire protection system which swells upon heating to form expanded multi-cellular char layer that protects the substrate from fire. In this research work, IFRC's were developed using different flame retardants such as ammonium polyphosphate, expandable graphite, melamine and boric acid. These flame retardants were bound together with the help of epoxy binder and cured together using curing agent. IFRC was then reinforced with nano magnesium oxide and nano alumina as inorganic fillers to study their effect towards fire performance, microstructure and thermal degradation. Small scale fire test was conducted to investigate the thermal insulation of coating whereas fire performance was calculated using thermal margin value. Field emission scanning electron microscopy was used to examine the microstructure of char obtained after fire test. Thermogravimetric analysis was conducted to investigate the residual weight of coating. Results showed that the performance of the coating was enhanced by reinforcement with nano size fillers as compared to non-filler based coating. Comparing both nano size magnesium oxide and nano size alumina; nano size alumina gave better fire performance with improved microstructure of char and high residual weight.
Study of aircraft crashworthiness for fire protection
NASA Technical Reports Server (NTRS)
Cominsky, A.
1981-01-01
Impact-survivable postcrash fire accidents were surveyed. The data base developed includes foreign and domestic accidents involving airlines and jet aircraft. The emphasis was placed on domestic accidents, airlines, and jet aircraft due principally to availability of information. Only transport category aircraft in commercial service designed under FAR Part 25 were considered. A matrix was prepared to show the relationships between the accident characteristics and the fire fatalities. Typical postcrash fire scenaries were identified. Safety concepts were developed for three engineering categories: cabin interiors - cabin subsystems; power plant - engines and fuel systems; and structural mechanics - primary and secondary structures. The parameters identified for concept evaluation are cost, effectiveness, and societal concerns. Three concepts were selected for design definition and cost and effectiveness analysis: improved fire-resistant seat materials; anti-misting kerosene; and additional cabin emergency exits.
Fuel loads, fire regimes, and post-fire fuel dynamics in Florida Keys pine forests
Sah, J.P.; Ross, M.S.; Snyder, J.R.; Koptur, S.; Cooley, H.C.
2006-01-01
In forests, the effects of different life forms on fire behavior may vary depending on their contributions to total fuel loads. We examined the distribution of fuel components before fire, their effects on fire behavior, and the effects of fire on subsequent fuel recovery in pine forests within the National Key Deer Refuge in the Florida Keys. We conducted a burning experiment in six blocks, within each of which we assigned 1-ha plots to three treatments: control, summer, and winter burn. Owing to logistical constraints, we burned only 11 plots, three in winter and eight in summer, over a 4-year period from 1998 to 2001. We used path analysis to model the effects of fuel type and char height, an indicator of fire intensity, on fuel consumption. Fire intensity increased with surface fuel loads, but was negatively related to the quantity of hardwood shrub fuels, probably because these fuels are associated with a moist microenvironment within hardwood patches, and therefore tend to resist fire. Winter fires were milder than summer fires, and were less effective at inhibiting shrub encroachment. A mixed seasonal approach is suggested for fire management, with burns applied opportunistically under a range of winter and summer conditions, but more frequently than that prevalent in the recent past. ?? IAWF 2006.
Impacts: NIST Building and Fire Research Laboratory (technical and societal)
NASA Astrophysics Data System (ADS)
Raufaste, N. J.
1993-08-01
The Building and Fire Research Laboratory (BFRL) of the National Institute of Standards and Technology (NIST) is dedicated to the life cycle quality of constructed facilities. The report describes major effects of BFRL's program on building and fire research. Contents of the document include: structural reliability; nondestructive testing of concrete; structural failure investigations; seismic design and construction standards; rehabilitation codes and standards; alternative refrigerants research; HVAC simulation models; thermal insulation; residential equipment energy efficiency; residential plumbing standards; computer image evaluation of building materials; corrosion-protection for reinforcing steel; prediction of the service lives of building materials; quality of construction materials laboratory testing; roofing standards; simulating fires with computers; fire safety evaluation system; fire investigations; soot formation and evolution; cone calorimeter development; smoke detector standards; standard for the flammability of children's sleepwear; smoldering insulation fires; wood heating safety research; in-place testing of concrete; communication protocols for building automation and control systems; computer simulation of the properties of concrete and other porous materials; cigarette-induced furniture fires; carbon monoxide formation in enclosure fires; halon alternative fire extinguishing agents; turbulent mixing research; materials fire research; furniture flammability testing; standard for the cigarette ignition resistance of mattresses; support of navy firefighter trainer program; and using fire to clean up oil spills.
METHOD OF MAKING REFRACTORY BODIES
Andersen, J.C.
1960-05-31
A method is given for the manufacture of silicon carbide bodies that are characterized by high density, high purity, and superior resistance to oxidative deterioration. Dense silicon bodies are obtained by a process in which granular silicon carbide, a carbonizable material, and a carbonaceous material are mixed together, the mixture is shaped as desired, and then the shape is fired in the presence of more than the stoichiometric amount of silicon. The carbonizable material preferably includes a temporary binder that is set before the firing step to hold the mix in shape for firing.
van Mantgem, Phillip J.; Caprio, Anthony C.; Stephenson, Nathan L.; Das, Adrian J.
2016-01-01
Prescribed fire is a primary tool used to restore western forests following more than a century of fire exclusion, reducing fire hazard by removing dead and live fuels (small trees and shrubs). It is commonly assumed that the reduced forest density following prescribed fire also reduces competition for resources among the remaining trees, so that the remaining trees are more resistant (more likely to survive) in the face of additional stressors, such as drought. Yet this proposition remains largely untested, so that managers do not have the basic information to evaluate whether prescribed fire may help forests adapt to a future of more frequent and severe drought.During the third year of drought, in 2014, we surveyed 9950 trees in 38 burned and 18 unburned mixed conifer forest plots at low elevation (<2100 m a.s.l.) in Kings Canyon, Sequoia, and Yosemite national parks in California, USA. Fire had occurred in the burned plots from 6 yr to 28 yr before our survey. After accounting for differences in individual tree diameter, common conifer species found in the burned plots had significantly reduced probability of mortality compared to unburned plots during the drought. Stand density (stems ha-1) was significantly lower in burned versus unburned sites, supporting the idea that reduced competition may be responsible for the differential drought mortality response. At the time of writing, we are not sure if burned stands will maintain lower tree mortality probabilities in the face of the continued, severe drought of 2015. Future work should aim to better identify drought response mechanisms and how these may vary across other forest types and regions, particularly in other areas experiencing severe drought in the Sierra Nevada and on the Colorado Plateau.
Alaska's Changing Fire Regime - Implications for the Vulnerability of Its Boreal Forests
NASA Technical Reports Server (NTRS)
Kasischke, E. S.; Hoy, E. E.; Verbyla, D. L.; Rupp, T. S.; Duffy, P. A.; McGuire, A. D.; Murphy, K. A.; Jandt, R.; Barnes, J. L.; Calef, M.;
2010-01-01
A synthesis was carried out to examine Alaska s boreal forest fire regime. During the 2000s, an average of 767 000 ha/year burned, 50% higher than in any previous decade since the 1940s. Over the past 60 years, there was a decrease in the number of lightning-ignited fires, an increase in extreme lightning-ignited fire events, an increase in human-ignited fires, and a decrease in the number of extreme human-ignited fire events. The fraction of area burned from humanignited fires fell from 26% for the 1950s and 1960s to 5% for the 1990s and 2000s, a result from the change in fire policy that gave the highest suppression priorities to fire events that occurred near human settlements. The amount of area burned during late-season fires increased over the past two decades. Deeper burning of surface organic layers in black spruce (Picea mariana (Mill.) BSP) forests occurred during late-growing-season fires and on more well-drained sites. These trends all point to black spruce forests becoming increasingly vulnerable to the combined changes of key characteristics of Alaska s fire regime, except on poorly drained sites, which are resistant to deep burning. The implications of these fire regime changes to the vulnerability and resilience of Alaska s boreal forests and land and fire management are discussed.
Alaska’s changing fire regime - Implications for the vulnerability of its boreal forests
Kasischke, Eric S.; Verbyla, David L.; Rupp, T. Scott; McGuire, A. David; Murphy, Karen A.; Jandt, R.; Barnes, Jennifer L.; Hoy, E.; Duffy, Paul A.; Calef, Monika; Turetsky, Merritt R.
2010-01-01
A synthesis was carried out to examine Alaska’s boreal forest fire regime. During the 2000s, an average of 767 000 ha·year–1 burned, 50% higher than in any previous decade since the 1940s. Over the past 60 years, there was a decrease in the number of lightning-ignited fires, an increase in extreme lightning-ignited fire events, an increase in human-ignited fires, and a decrease in the number of extreme human-ignited fire events. The fraction of area burned from human-ignited fires fell from 26% for the 1950s and 1960s to 5% for the 1990s and 2000s, a result from the change in fire policy that gave the highest suppression priorities to fire events that occurred near human settlements. The amount of area burned during late-season fires increased over the past two decades. Deeper burning of surface organic layers in black spruce (Picea mariana (Mill.) BSP) forests occurred during late-growing-season fires and on more well-drained sites. These trends all point to black spruce forests becoming increasingly vulnerable to the combined changes of key characteristics of Alaska’s fire regime, except on poorly drained sites, which are resistant to deep burning. The implications of these fire regime changes to the vulnerability and resilience of Alaska’s boreal forests and land and fire management are discussed.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-02
... Electric Utility Steam Generating Units and Standards of Performance for Fossil-Fuel-Fired Electric Utility...-fired Electric Utility Steam Generating Units and Standards of Performance for Fossil-Fuel-Fired...
14 CFR 27.952 - Fuel system crash resistance.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System § 27.952 Fuel system... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel system crash resistance. 27.952... of fuel fires to occupants following an otherwise survivable impact (crash landing), the fuel systems...
14 CFR 27.952 - Fuel system crash resistance.
Code of Federal Regulations, 2012 CFR
2012-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System § 27.952 Fuel system... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fuel system crash resistance. 27.952... of fuel fires to occupants following an otherwise survivable impact (crash landing), the fuel systems...
14 CFR 27.952 - Fuel system crash resistance.
Code of Federal Regulations, 2014 CFR
2014-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System § 27.952 Fuel system... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fuel system crash resistance. 27.952... of fuel fires to occupants following an otherwise survivable impact (crash landing), the fuel systems...
14 CFR 29.952 - Fuel system crash resistance.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.952 Fuel system... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel system crash resistance. 29.952... of fuel fires to occupants following an otherwise survivable impact (crash landing), the fuel systems...
14 CFR 29.952 - Fuel system crash resistance.
Code of Federal Regulations, 2012 CFR
2012-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.952 Fuel system... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fuel system crash resistance. 29.952... of fuel fires to occupants following an otherwise survivable impact (crash landing), the fuel systems...
14 CFR 29.952 - Fuel system crash resistance.
Code of Federal Regulations, 2011 CFR
2011-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.952 Fuel system... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fuel system crash resistance. 29.952... of fuel fires to occupants following an otherwise survivable impact (crash landing), the fuel systems...
14 CFR 29.952 - Fuel system crash resistance.
Code of Federal Regulations, 2013 CFR
2013-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.952 Fuel system... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fuel system crash resistance. 29.952... of fuel fires to occupants following an otherwise survivable impact (crash landing), the fuel systems...
14 CFR 29.952 - Fuel system crash resistance.
Code of Federal Regulations, 2014 CFR
2014-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.952 Fuel system... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fuel system crash resistance. 29.952... of fuel fires to occupants following an otherwise survivable impact (crash landing), the fuel systems...
14 CFR 27.952 - Fuel system crash resistance.
Code of Federal Regulations, 2013 CFR
2013-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System § 27.952 Fuel system... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fuel system crash resistance. 27.952... of fuel fires to occupants following an otherwise survivable impact (crash landing), the fuel systems...
14 CFR 27.952 - Fuel system crash resistance.
Code of Federal Regulations, 2011 CFR
2011-01-01
... AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System § 27.952 Fuel system... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fuel system crash resistance. 27.952... of fuel fires to occupants following an otherwise survivable impact (crash landing), the fuel systems...
Nancy Shaw; Beth Newingham; Amy C. Ganguli; Ann L. Hild; Robert D. Cox; Jim Truax; Mike Pellant; David Pyke; Dan Ogle
2011-01-01
Annual grass invasion in the Great Basin has increased fire size, frequency and severity. Post-fire restoration to provide functional native plant communities is critical to improve resistance to weed invasion. Our ability to successfully re-establish mixtures of native grasses, forbs and shrubs, however, is limited. We examined the effects of the standard rangeland...
Variation among northern red oak provenances in bark thickness:dbh ratios
Matthew S. Russell; Jeffrey O. Dawson
1995-01-01
Differences in bark thickness in relation to diameter at breast height were observed in a 30-32 year old Illinois planting of 32 provenances of northern red oak (Quercus rubra) from throughout its natural range. Bark thickness by itself is often a good indication of relative cambial insulation from fire. Fire resistance in trees can largely be...
Air-Powered Projectile Launcher
NASA Technical Reports Server (NTRS)
Andrews, T.; Bjorklund, R. A.; Elliott, D. G.; Jones, L. K.
1987-01-01
Air-powered launcher fires plastic projectiles without using explosive propellants. Does not generate high temperatures. Launcher developed for combat training for U.S. Army. With reservoir pressurized, air launcher ready to fire. When pilot valve opened, sleeve (main valve) moves to rear. Projectile rapidly propelled through barrel, pushed by air from reservoir. Potential applications in seismic measurements, avalanche control, and testing impact resistance of windshields on vehicles.
46 CFR 164.007-9 - Procedure for approval.
Code of Federal Regulations, 2012 CFR
2012-10-01
.... (1) If the manufacturer desires to have the test conducted at some laboratory other than the National... sample or samples for the fire resistance test will be given at this time, together with the estimated...″×12″) sample and a 60 cm. × 60cm. (24″×24″) sample for each thickness and density proposed to the Fire...
46 CFR 164.007-9 - Procedure for approval.
Code of Federal Regulations, 2011 CFR
2011-10-01
.... (1) If the manufacturer desires to have the test conducted at some laboratory other than the National... sample or samples for the fire resistance test will be given at this time, together with the estimated...″×12″) sample and a 60 cm. × 60cm. (24″×24″) sample for each thickness and density proposed to the Fire...
A Shelterwood-Burn Technique for Regenerating Productive Upland Oak Sites in the Piedmont Region
Patrick H. Brose; David H. van Lear; Patrick D. Keyser
1999-01-01
Regenerating oak stands on productive uplandsires is widely recognized byforesters as a major problem in hardwood management. Recent research indicates that oak regeneration is more resistant to surface fires than its primary competitors on these sites if burning occurs 3 to 5 yr after a partial overstory harvest. This combination of cutting followed by fire (...
Use of class a foams on structures and wildlands
Paul Schlobohm
1995-01-01
The increase of homes in wildlands indicates a significant change. The build-up of fuels around homes and in wildlands over time also indicates change. Resistance to change, however, remains the norm. Fires get worse, but plain water continues to be used for fire suppression and property protection. With Class A foam, the objectives of protection are to wet the...
NASA Astrophysics Data System (ADS)
Burye, Theodore E.; Nicholas, Jason D.
2015-02-01
Here, for the first time, the average size of solid oxide fuel cell (SOFC) electrode nano-particles was reduced through the chemical desiccation of infiltrated precursor nitrate solutions. Specifically, after firing at 700 °C, CaCl2-desiccated La0.6Sr0.4Co0.8Fe0.2O3-δ (LSCF) - Ce0.9Gd0.1O1.95 (GDC) cathodes contained LSCF infiltrate particles with an average size of 22 nm. This is in contrast to comparable, undesiccated LSCF-GDC cathodes which contained LSCF infiltrate particles with an average size of 48 nm. X-ray diffraction, scanning electron microscopy, and controlled atmosphere electrochemical impedance spectroscopy revealed that desiccation reduced the average infiltrate particle size without altering the infiltrate phase purity, the cathode concentration polarization resistance, or the cathode electronic resistance. Compared to undesiccated LSCF-GDC cathodes achieving polarization resistances of 0.10 Ωcm2 at 640 °C, comparable CaCl2-dessicated LSCF-GDC cathodes achieved 0.10 Ωcm2 at 575 °C. Mathematical modeling suggested that these performance improvements resulted solely from average infiltrate particle size reductions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yamamoto, Yukinori; Babu, Prof. Sudarsanam Suresh; Shassere, Benjamin
Two different approaches have been proposed for improvement of cross-weld creep properties of the high temperature ferrous structural materials for fossil-fired energy applications. The traditional creep strength-enhanced ferritic (CSEF) steel weldments suffer from Type IV failures which occur at the fine-grained heat affected zone (FGHAZ). In order to minimize the premature failure at FGHAZ in the existing CSEF steels, such as modified 9Cr-1Mo ferritic-martensitic steels (Grade 91), a thermo-mechanical treatment consisting of aus-forging/rolling and subsequent aus-aging is proposed which promotes the formation of stable MX carbonitrides prior to martensitic transformation. Such MX remains undissolved during welding process, even in FGHAZ,more » which successfully improves the cross-weld creep properties. Another approach is to develop a new fully ferrtic, creep-resistant FeCrAl alloy which is essentially free from Type IV failure issues. Fe-30Cr-3Al base alloys with minor alloying additions were developed which achieved a combination of good oxidation/corrosion resistance and improved tensile and creep performance comparable or superior to Grade 92 steel.« less
Prevention of residential roof fires by use of a class "A" fire rated roof system.
Edlich, Richard F; Winters, Kathryne L; Long, William B; Britt, L D
2004-01-01
Because residential roof fires remain a life-threatening danger to residential homeowners in the United States, we describe in detail a national fire prevention program for reducing residential roof fires by use of an Underwriters Laboratories Inc. (UL) and National Fire Protection Association Class A fire rated roof system. This Class A system should comply with the test requirements for fire resistance of roof coverings, as outlined in UL 790 or in ASTM International (ASTM) E-108. Both the Asphalt Roofing Manufacturer's Association (ARMA) and the National Roofing Contractors Association (NRCA) have set up guidelines for selecting a new roof for the homeowner. Class A, fiber-glass-based asphalt roofing shingles represent an overwhelming share of the United States residential roofing market, and, as such, the Class A rated roofing system remains an excellent alternative to wood shingles and shakes. Fortunately, the Class A fire rating is available for certain wood shingle products that incorporate a factory-applied, fire resistant treatment. However, in this circumstance, wood products labeled as Class B shakes or shingles must be installed over spaced or solid sheathing that have been covered either with one layer of 1/4 in. (6.4 mm) thick noncombustible roof board, or with one layer of minimum 72-lb. fiber-glass-based mineral surfaced cap sheet, or with another specialty roofing sheet to obtain the Class A fire rating. Clay, tile, slate, and metal have been assigned Class A fire ratings in the codes (but often without testing). These alternative roofing materials are often considerably more expensive. Proper application, ventilation, and insulation of roofing systems are required to prevent heat and moisture buildup in the attic, which can damage the roofing system, making it more susceptible to water leakage as well as ignition in the event of a fire. The NRCA has devised excellent recommendations for the homeowner to prequalify the contractor. In addition, a warranty for any new roofing material is important for the homeowner to ensure that the roofing can be repaired by the contractor or manufacturer during the specified warranty period, in case of contractor error or a manufacturing defect. In addition, the homeowner should ensure that the warranty is transferable to any future owner of the home to allow the buyer to have the same warranty benefits as the original owner. The State of California has mandated strict roofing requirements to prevent residential fires. In the absence of this legislation in other states, the homeowner must follow the guidelines outlined in this collective review to ensure that a roofing system with Class A fire protection is installed. Other fire safety precautions that should also be considered mandatory are to include smoke alarms, escape plans, and retrofit fire sprinklers.
Wildfires in Siberian Mountain Forest
NASA Astrophysics Data System (ADS)
Kharuk, V.; Ponomarev, E. I.; Antamoshkina, O.
2017-12-01
The annual burned area in Russia was estimated as 0.55 to 20 Mha with >70% occurred in Siberia. We analyzed Siberian wildfires distribution with respect to elevation, slope steepness and exposure. In addition, wildfires temporal dynamic and latitudinal range were analyzed. We used daily thermal anomalies derived from NOAA/AVHRR and Terra/MODIS satellites (1990-2016). Fire return intervals were (FRI) calculated based on the dendrochronology analysis of samples taken from trees with burn marks. Spatial distribution of wildfires dependent on topo features: relative burned area increase with elevation increase (ca. 1100 m), switching to following decrease. The wildfires frequency exponentially decreased within lowlands - highlands transition. Burned area is increasing with slope steepness increase (up to 5-10°). Fire return intervals (FRI) on the southfacing slopes are about 30% longer than on the north facing. Wildfire re-occurrence is decreasing exponentially: 90% of burns were caused by single fires, 8.5% by double fires, 1% burned three times, and on about 0.05% territory wildfires occurred four times (observed period: 75 yr.). Wildfires area and number, as well as FRI, also dependent on latitude: relative burned area increasing exponentially in norward direction, whereas relative fire number is exponentially decreasing. FRI increases in the northward direction: from 80 years at 62°N to 200 years at the Arctic Circle, and to 300 years at the northern limit of closed forests ( 71+°N). Fire frequency, fire danger period and FRI are strongly correlated with incoming solar radiation (r = 0.81 - 0.95). In 21-s century, a positive trend of wildfires number and area observed in mountain areas in all Siberia. Thus, burned area and number of fires in Siberia are significantly increased since 1990th (R2 =0.47, R2 =0.69, respectively), and that increase correlated with air temperatures and climate aridity increases. However, wildfires are essential for supporting fire-resistant species (e.g., Larix sibirica, L, dahurica and Pinus silvestris) reforestation and completion with non-fire-resistant species. This work was supported by the Russian Foundation for Basic Research, the Government of the Krasnoyarsk krai, the Krasnoyarsk Fund for Support of Scientific and Technological Activities (N 17-41-240475)
One-pot, bioinspired coatings to reduce the flammability of flexible polyurethane foams.
Davis, Rick; Li, Yu-Chin; Gervasio, Michelle; Luu, Jason; Kim, Yeon Seok
2015-03-25
In this manuscript, natural materials were combined into a single "pot" to produce flexible, highly fire resistant, and bioinspired coatings on flexible polyurethane foam (PUF). In one step, PUF was coated with a fire protective layer constructed of a polysaccharide binder (starch or agar), a boron fire retardant (boric acid or derivative), and a dirt char former (montmorillonite clay). Nearly all coatings produced a 63% reduction in a critical flammability value, the peak heat release rate (PHRR). One formulation produced a 75% reduction in PHRR. This technology was validated in full-scale furniture fire tests, where a 75% reduction in PHRR was measured. At these PHRR values, this technology could reduce the fire threat of furniture from significant fire damage in and beyond the room of fire origin to being contained to the burning furniture. This flammability reduction was caused by three mechanisms-the gas-phase and condensed-phase processes of the boron fire retardant and the condensed-phase process of the clay. We describe the one-pot coating process and the impact of the coating composition on flammability.
Fire containment tests of aircraft interior panels
NASA Technical Reports Server (NTRS)
Kourtides, D. A.; Parker, J. A.; Leon, H. A.; Williamson, R. B.; Hasegawa, H.; Fisher, F.; Draemel, R.; Marcussen, W. H.; Hilado, C. J.
1976-01-01
The paper describes an experimental program carried out to evaluate a possible method for testing the fire-containment qualities of aircraft interior panels. The experimental apparatus consisted of a burner that simulates various fire loads under different ventilation conditions in an enclosure of approximately the same size as an aircraft lavatory module. Two fire-containment tests are discussed in which two adjoining walls of the enclosure were made from state-of-the-art composite panels; rats were exposed to the combustion products in order to evaluate the toxic threat posed by those products. The results show that the burner can be employed to represent various fire-load conditions and that the methodology developed for fire containment can be useful in evaluating the fire resistance of composite panels before conducting large-scale tests. It is concluded that elements of the fire-containment criteria include the temperature rise on the backface of the panels as a function of time, the flame burn-through by either decomposition or severe distortion of the material, and the toxicity of the combustion gases evolved.
Gaucher, Matthieu; Dugé de Bernonville, Thomas; Guyot, Sylvain; Dat, James F; Brisset, Marie-Noëlle
2013-11-01
The necrogenic bacterium Erwinia amylovora responsible for the fire blight disease causes cell death in apple tissues to enrich intercellular spaces with nutrients. Apple leaves contain large amounts of dihydrochalcones (DHCs), including phloridzin and its aglycone phloretin. Previous work showed an important decrease in the constitutive DHCs stock in infected leaves, probably caused by transformation reactions during the infection process. At least two flavonoid transformation pathways have been described so far: deglucosylation and oxidation. The aim of the present study was to determine whether DHCs are differentially converted in two apple genotypes displaying contrasted susceptibilities to the disease. Different analyses were performed: i) enzymatic activity assays in infected leaves, ii) identification/quantification of end-products obtained after in vitro enzymatic reactions with DHCs, iii) evaluation of the bactericidal activity of end-products. The results of the enzymatic assays showed that deglucosylation was dominant over oxidation in the susceptible genotype MM106 while the opposite was observed in the resistant genotype Evereste. These data were confirmed by LC-UV/Vis-MS analysis of in vitro reaction mixtures, especially because higher levels of o-quinoid oxidation products of phloretin were measured by using the enzymatic extracts of Evereste infected leaves. Their presence correlated well with a strong bactericidal activity of the reaction mixtures. Thus, our results suggest that a differential transformation of DHCs occur in apple genotypes with a potential involvement in the establishment of the susceptibility or the resistance to fire blight, through the release of glucose or of highly bactericidal compounds respectively. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ross, B.; Parker, J.
1983-12-01
Properties of copper pastes did not reproduce earlier results in rheology and metallurgy. Electrodes made with pastes produced under the previous contract were analyzed and raw material characteristics were compared. A needle-like structure was observed on the earlier electroded solar cells, and was identified as eutectic copper-silicon. Experiments were conducted with variations in paste parameters, firing conditions, including gas ambients, furnace furniture, silicon surface and others to improve performance characteristics. Improved adhesion with copper pastes containing silver fluoride, as well as those containing fluorocarbon powder was obtained. Front contact experiments were done with silver fluoride activated pastes on bare silicon,more » silicon oxide and silicon nitride coated silicon wafers. Adhesion of pastes with AgF on silicon nitride coated wafers was good, but indications were that all cells were shunted and the conclusion was that these systems were unsuitable for front contacts. Experiments with aluminum back surfaces and screened contacts to that surface were begun. Low temperature firing tended to result in S shaped IV curves. This was attributed to a barrier formed at the silicon-copper interface. A cooperative experiment was initiated on the effect of heat-treatments in various atmospheres on the hydrogen profile of silicon surfaces. Contact theory was explored to determine the role of various parameters on tunneling and contact resistance. Data confirm that the presence of eutectic Al-Si additions are beneficial for low contact resistance and fill factors in back contacts. Copper pastes with different silver fluoride additions were utilized as front contacts at two temperatures. Data shows various degrees of shunting. Finally, an experiment was run with carbon monoxide gas used as the reducing ambient during firing.« less
van Mantgem, Philip J.; Nesmith, Jonathan C. B.; Keifer, MaryBeth; Brooks, Matthew
2012-01-01
The reintroduction of fire to historically fire-prone forests has been repeatedly shown to reduce understory fuels and promote resistance to high severity fire. However, there is concern that prescribed fire may also have unintended consequences, such as high rates of mortality for large trees and fire-tolerant Pinus species. To test this possibility we evaluated mortality patterns for two common genera in the western US, Pinus and Abies, using observations from a national-scale prescribed fire effects monitoring program. Our results show that mortality rates of trees >50 DBH were similar for Pinus (4.6% yr-1) and Abies (4.0% yr-1) 5 years following prescribed fires across seven sites in the southwestern US. In contrast, mortality rates of trees >50 cm DBH differed between Pinus (5.7% yr-1) and Abies (9.0% yr-1). Models of post-fire mortality probabilities suggested statistically significant differences between the genera (after including differences in bark thickness), but accounting for these differences resulted in only small improvements in model classification. Our results do not suggest unusually high post-fire mortality for large trees or for Pinus relative to the other common co-occurring genus, Abies, following prescribed fire in the southwestern US.
The effect of leaf beetle herbivory on the fire behaviour of tamarisk (Tamarix ramosissima Lebed.)
Drus, Gail M.; Dudley, Tom L.; Brooks, Matthew L.; Matchett, John R.
2012-01-01
The non-native tree, Tamarix spp. has invaded desert riparian ecosystems in the south-western United States. Fire hazard has increased, as typically fire-resistant native vegetation is replaced by Tamarix. The tamarisk leaf beetle, Diorhabda carinulata Desbrochers, introduced for biological control, may affect fire behaviour by converting hydrated live Tamarix leaves and twigs into desiccated and dead fuels. This potentially increases fire hazard in the short term before native vegetation can be re-established. This study investigates how fire behaviour is altered in Tamarix fuels desiccated by Diorhabda herbivory at a Great Basin site, and by herbivory simulated by foliar herbicide at a Mojave Desert site. It also evaluates the influence of litter depth on fire intensity. Fire behaviour was measured with a fire intensity index that integrates temperature and duration (degree-minutes above 70°C), and with maximum temperature, duration, flame lengths, rates of spread and vegetation removal. Maximum temperature, flame length and rate of spread were enhanced by foliar desiccation of Tamarix at both sites. At only the Mojave site, there was a trend for desiccated trees to burn with greater fire intensity. At both sites, fire behaviour parameters were influenced to a greater degree by litter depth, vegetation density and drier and windier conditions than by foliar desiccation.
Geothermal materials development
NASA Astrophysics Data System (ADS)
Kukacka, L. E.
1991-12-01
Advances in the development of new materials, the commercial availabilities of which are essential for the attainment of Hydrothermal Category Level 1 and 2 Objectives, continue to be made in the Geothermal Materials Development Project. Many successes have already been accrued and the results used commercially. In FY-91, utility company sponsored 'full cost' recovery programs based upon materials technology developed in this project were initiated on topics such as condensing heat exchangers, high temperature composites for utility vaults used in district heating systems, and corrosion resistant coatings for use in oil-fired electric generating processes. In FY-91, the DOE/GD-sponsored R&D project was focused on reducing well drilling, fluid transport and energy conversion costs. Specific activities being performed included lightweight CO2-resistant well cements, chemical systems for lost circulation control, thermally conductive and scale resistant protective linear systems, corrosion mitigation in process components at The Geysers, and elastomer-metal bonding systems needed for use in high temperature well drilling and safety related applications.
46 CFR 154.1125 - Pipes, fittings, and valves.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., fitting, and valve for the water spray system must be made of fire resistant and corrosion resistant materials, such as galvanized steel or galvanized iron pipe. (e) Each water spray system must have a means of drainage to prevent corrosion of the system and freezing of accumulated water in subfreezing...
46 CFR 154.1125 - Pipes, fittings, and valves.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., fitting, and valve for the water spray system must be made of fire resistant and corrosion resistant materials, such as galvanized steel or galvanized iron pipe. (e) Each water spray system must have a means of drainage to prevent corrosion of the system and freezing of accumulated water in subfreezing...
27 CFR 555.208 - Construction of type 2 magazines.
Code of Federal Regulations, 2010 CFR
2010-04-01
... magazines. 555.208 Section 555.208 Alcohol, Tobacco Products, and Firearms BUREAU OF ALCOHOL, TOBACCO... Construction of type 2 magazines. A type 2 magazine is a box, trailer, semitrailer, or other mobile facility. (a) Outdoor magazines—(1) General. Outdoor magazines are to be bullet-resistant, fire-resistant...
Does a drop in the bucket make a splash? Assessing the impact of antibiotic use on plants.
McManus, Patricia S
2014-06-01
Antibiotics are applied to plants to prevent bacterial diseases, although the diversity of antibiotics and total amounts used are dwarfed by antibiotic use in animal agriculture. Nevertheless, the release of antibiotics into the open environment during crop treatment draws scrutiny for its potential impact on the global pool of resistance genes. The main use of antibiotics on plants is application of streptomycin to prevent fire blight, a serious disease of apple and pear trees. A series of recent studies identified and quantified antibiotic resistance genes and profiled bacterial communities in apple orchard plots that were or were not sprayed with streptomycin. While the specific objectives and methods varied, the results of these studies suggest that streptomycin application for fire blight control does not influence bacterial community structure or increase the abundance of resistance genes in orchards. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Thompson, J. E.; Wittman, J. W.; Reynard, K. A.
1976-01-01
Candidate polyphosphazene polymers were investigated to develop a fire-resistant, thermally stable and flexible open cell foam. The copolymers were prepared in several mole ratios of the substituent side chains and a (nominal) 40:60 derivative was selected for formulation studies. Synthesis of the polymers involved solution by polymerization of hexachlorophosphazene to soluble high molecular weight poly(dichlorophosphazene), followed by derivatization of the resultant polymer in a normal fashion to give polymers in high yield and high molecular weight. Small amounts of a cure site were incorporated into the polymer for vulcanization purposes. The poly(aryloxyphosphazenes) exhibited good thermal stability and the first polymer mentioned above exhibited the best thermal behavior of all the candidate polymers studied.
Screen printed, transparent, and flexible electrodes based on graphene nanoplatelet pastes
NASA Astrophysics Data System (ADS)
Wróblewski, Grzegorz; Janczak, Daniel
Transparent, flexible and conducting graphene films were produced by screen printing method using printing pastes based on graphene nanoplatelets in polymer matrix. The transparency of received layers and the mechanical resistivity in several bending cycles were measured. Subsequently percolation threshold was investigated. Graphene layers were printed on diverse substrates (glass, Al2O3, PET) and afterwards for samples printed on glass different firing atmospheres (N2, H2, air) were studied. Best firing results (resistance decrease) were obtained for treatment in 250 °C in atmosphere of air. Finally investigation results were used to produce a transparent and elastic electrode for an electroluminescent display, showing the application potential of our graphene nanocomposite pastes.
NASA Technical Reports Server (NTRS)
Olson, S. L.
2004-01-01
NASA's current method of material screening determines fire resistance under conditions representing a worst-case for normal gravity flammability - the Upward Flame Propagation Test (Test 1). Its simple pass-fail criteria eliminates materials that burn for more than 12 inches from a standardized ignition source. In addition, if a material drips burning pieces that ignite a flammable fabric below, it fails. The applicability of Test 1 to fires in microgravity and extraterrestrial environments, however, is uncertain because the relationship between this buoyancy-dominated test and actual extraterrestrial fire hazards is not understood. There is compelling evidence that the Test 1 may not be the worst case for spacecraft fires, and we don t have enough information to assess if it is adequate at Lunar or Martian gravity levels.
NASA Technical Reports Server (NTRS)
Olson, S. L.
2004-01-01
NASA s current method of material screening determines fire resistance under conditions representing a worst-case for normal gravity flammability - the Upward Flame Propagation Test (Test 1[1]). Its simple pass-fail criteria eliminates materials that burn for more than 12 inches from a standardized ignition source. In addition, if a material drips burning pieces that ignite a flammable fabric below, it fails. The applicability of Test 1 to fires in microgravity and extraterrestrial environments, however, is uncertain because the relationship between this buoyancy-dominated test and actual extraterrestrial fire hazards is not understood. There is compelling evidence that the Test 1 may not be the worst case for spacecraft fires, and we don t have enough information to assess if it is adequate at Lunar or Martian gravity levels.
Elastic resistance change and action potential generation of non-faradaic Pt/TiO2/Pt capacitors.
Lim, Hyungkwang; Jang, Ho Won; Lee, Doh-Kwon; Kim, Inho; Hwang, Cheol Seong; Jeong, Doo Seok
2013-07-21
Electric current in the mixed ionic-electronic conductor TiO2 is hysteretic, i.e. history-dependent, and its use is versatile in electronic devices. Nowadays, biologically inspired, analogue-type computing systems, known as neuromorphic systems, are being actively investigated owing to their new and intriguing physical concepts. The realization of artificial synapses is important for constructing neuromorphic systems. In mammalians' brains, the plasticity of synapses between neighbouring nerve cells arises from action potential firing. Emulating action potential firing via inorganic systems has therefore become important in neuromorphic engineering. In this work, the current-voltage hysteresis of TiO2-based non-faradaic capacitors is investigated to primarily focus on the correlation between the blocking contact and the elasticity, i.e. non-plasticity, of the capacitors' resistance change, in experimental and theoretical methods. The similarity between the action potential firing behaviour in nerve cells and the elasticity of the non-faradaic capacitors is addressed.
The Assessment of Cement Mortars after Thermal Degradation by Acoustic Non-destructive Methods
NASA Astrophysics Data System (ADS)
Topolář, L.; Štefková, D.; Hoduláková, M.
2017-10-01
Thanks, the terrorist attacks on the worldwide interest in the design of structures for fire greatly increased. One of the advantages of concrete over other building materials is its inherent fire-resistive properties. The concrete structural components still must be able to withstand dead and live loads without collapse even though the rise in temperature causes a decrease in the strength and modulus of elasticity for concrete and steel reinforcement. In addition, fully developed fires cause expansion of structural components and the resulting stresses and strains must be resisted. This paper reports the results of measurements by Impact-echo method and measurement by ultrasound. Both methods are based on the acoustic properties of the material which are dependent on its condition. These acoustic methods allow identifying defects and are thus suitable for monitoring the building structure condition. The results are obtained in the laboratory during the degradation of composite materials based on cement by high-temperature.
On the temperature prediction in a fire escape passage
NASA Astrophysics Data System (ADS)
Casano, G.; Piva, S.
2017-11-01
Fire safety engineering requires a detailed understanding of fire behaviour and of its effects on structures and people. Many factors may condition the fire scenario, as for example, heat transfer between the flame and the boundary structures. Currently advanced numerical codes for the prediction of the fire behaviour are available. However, these solutions often require heavy calculations and long times. In this context analytical solutions can be useful for a fast analysis of simplified schematizations. After that, it is more effective the final utilization of the advanced fire codes. In this contribution, the temperature in a fire escape passage, separated with a thermally resistant wall from a fire room, is analysed. The escape space is included in a building where the neighbouring rooms are at a constant undisturbed temperature. The presence of the neighbouring rooms is considered with an equivalent heat transfer coefficient, in a boundary condition of the third type. An analytical solution is used to predict the temperature distribution during the fire. It allows to obtain useful information on the temperature reached in the escape area in contact with a burning room; it is useful also for a fast choice of the thermal characteristics of a firewall.
Gene-for-gene relationship in the host-pathogen system Malus × robusta 5-Erwinia amylovora.
Vogt, Isabelle; Wöhner, Thomas; Richter, Klaus; Flachowsky, Henryk; Sundin, George W; Wensing, Annette; Savory, Elizabeth A; Geider, Klaus; Day, Brad; Hanke, Magda-Viola; Peil, Andreas
2013-03-01
Fire blight is a destructive bacterial disease caused by Erwinia amylovora affecting plants in the family Rosaceae, including apple. Host resistance to fire blight is present mainly in accessions of Malus spp. and is thought to be quantitative in this pathosystem. In this study we analyzed the importance of the E. amylovora effector avrRpt2(EA) , a homolog of Pseudomonas syringae avrRpt2, for resistance of Malus × robusta 5 (Mr5). The deletion mutant E. amylovora Ea1189ΔavrRpt2(EA) was able to overcome the fire blight resistance of Mr5. One single nucleotide polymorphism (SNP), resulting in an exchange of cysteine to serine in the encoded protein, was detected in avrRpt2(EA) of several Erwinia strains differing in virulence to Mr5. E. amylovora strains encoding serine (S-allele) were able to overcome resistance of Mr5, whereas strains encoding cysteine (C-allele) were not. Allele specificity was also observed in a coexpression assay with Arabidopsis thaliana RIN4 in Nicotiana benthamiana. A homolog of RIN4 has been detected and isolated in Mr5. These results suggest a system similar to the interaction of RPS2 from A. thaliana and AvrRpt2 from P. syringae with RIN4 as guard. Our data are suggestive of a gene-for-gene relationship for the host-pathogen system Mr5 and E. amylovora. No claim to original US government works. New Phytologist © 2013 New Phytologist Trust.
Fire danger index efficiency as a function of fuel moisture and fire behavior.
Torres, Fillipe Tamiozzo Pereira; Romeiro, Joyce Machado Nunes; Santos, Ana Carolina de Albuquerque; de Oliveira Neto, Ricardo Rodrigues; Lima, Gumercindo Souza; Zanuncio, José Cola
2018-08-01
Assessment of the performance of forest fire hazard indices is important for prevention and management strategies, such as planning prescribed burnings, public notifications and firefighting resource allocation. The objective of this study was to evaluate the performance of fire hazard indices considering fire behavior variables and susceptibility expressed by the moisture of combustible material. Controlled burns were carried out at different times and information related to meteorological conditions, characteristics of combustible material and fire behavior variables were recorded. All variables analyzed (fire behavior and fuel moisture content) can be explained by the prediction indices. The Brazilian EVAP/P showed the best performance, both at predicting moisture content of the fuel material and fire behavior variables, and the Canadian system showed the best performance to predicting the rate of spread. The coherence of the correlations between the indices and the variables analyzed makes the methodology, which can be applied anywhere, important for decision-making in regions with no records or with only unreliable forest fire data. Copyright © 2018 Elsevier B.V. All rights reserved.
Williams, Mark S.; Altwegg‐Boussac, Tristan; Chavez, Mario; Lecas, Sarah; Mahon, Séverine
2016-01-01
Key points Absence seizures are accompanied by spike‐and‐wave discharges in cortical electroencephalograms. These complex paroxysmal activities, affecting the thalamocortical networks, profoundly alter cognitive performances and preclude conscious perception.Here, using a well‐recognized genetic model of absence epilepsy, we investigated in vivo how information processing was impaired in the ictogenic neurons, i.e. the population of cortical neurons responsible for seizure initiation.In between seizures, ictogenic neurons were more prone to generate bursting activity and their firing response to weak depolarizing events was considerably facilitated compared to control neurons.In the course of seizures, information processing became unstable in ictogenic cells, alternating between an increased and a decreased responsiveness to excitatory inputs, depending on the spike and wave patterns.The state‐dependent modulation in the excitability of ictogenic neurons affects their inter‐seizure transfer function and their time‐to‐time responsiveness to incoming inputs during absences. Abstract Epileptic seizures result from aberrant cellular and/or synaptic properties that can alter the capacity of neurons to integrate and relay information. During absence seizures, spike‐and‐wave discharges (SWDs) interfere with incoming sensory inputs and preclude conscious experience. The Genetic Absence Epilepsy Rats from Strasbourg (GAERS), a well‐established animal model of absence epilepsy, allows exploration of the cellular basis of this impaired information processing. Here, by combining in vivo electrocorticographic and intracellular recordings from GAERS and control animals, we investigated how the pro‐ictogenic properties of seizure‐initiating cortical neurons modify their integrative properties and input–output operation during inter‐ictal periods and during the spike (S‐) and wave (W‐) cortical patterns alternating during seizures. In addition to a sustained depolarization and an excessive firing rate in between seizures, ictogenic neurons exhibited a pronounced hyperpolarization‐activated depolarization compared to homotypic control neurons. Firing frequency versus injected current relations indicated an increased sensitivity of GAERS cells to weak excitatory inputs, without modifications in the trial‐to‐trial variability of current‐induced firing. During SWDs, the W‐component resulted in paradoxical effects in ictogenic neurons, associating an increased membrane input resistance with a reduction in the current‐evoked firing responses. Conversely, the collapse of cell membrane resistance during the S‐component was accompanied by an elevated current‐evoked firing relative to W‐sequences, which remained, however, lower compared to inter‐ictal periods. These findings show a dynamic modulation of ictogenic neurons’ intrinsic properties that may alter inter‐seizure cortical function and participate in compromising information processing in cortical networks during absences. PMID:27311433
NASA Technical Reports Server (NTRS)
Gagliani, J.
1978-01-01
A new approach to the problem of flammability by the use of materials obtained from foamy polyimide resins is developed. The ability of these materials to provide fire protection is demonstrated. The development of processes for producing resilient cell foam for use in aircraft seating, thermal acoustical insulation, floor and wall panels, coated glass fabrics, and molded hardware.
2011-12-15
just two of the major UNCLASSIFIED UNCLASSIFIED vi technical hurdles that the FRF program was unable to clear. The logistical burden associated...Differences between JP-8 and DF-2 fuel are also discussed. The vehicle fuel fires experienced in combat situations occur in two distinct phases. The first...segregated in two groups, micro and macro-emulsions. These groups differ by the size of the suspended water droplets. Most of the emulsions
Jonathan D. Coop; Lisa Holsinger; Sarah McClernan; Sean A. Parks
2015-01-01
Land use legacies and climate have altered fire regimes across montane forests of much of the southwestern US (Allen and others 2002), and several recent wildfires have been extremely large and severe (Dennison and others 2014). Large openings resulting from high-severity fire in former ponderosa pine (Pinus ponderosa) and mixed conifer forests may be persistent given...
USDA-ARS?s Scientific Manuscript database
The AvrRpt2EA effector protein of Erwinia amylovora is important for pathogen recognition in the fire blight resistant crabapple Malus ×robusta 5; however, little is known about its role in susceptible apple genotypes. In order to study its function in planta, we expressed a plant optimized version...
The effect of heat treatment simulating porcelain firing processes on titanium corrosion resistance.
Sokołowski, Grzegorz; Rylska, Dorota; Sokołowski, Jerzy
2016-01-01
Corrosion resistance of titanium used in metal-ceramic restorations in manufacturing is based on the presence of oxide layer on the metal surface. The procedures used during combining metallic material with porcelain may affect the changes in oxide layers structure, and thus anticorrosive properties of metallic material. The aim of the study was an evaluation of potential changes in the structure and selected corrosion properties of titanium after sandblasting and thermal treatment applicable to the processes of ceramics fusion. Milled titanium elements were subjected to a few variants of the processes typical of ceramics fusion and studied in terms of resistance to electrochemical corrosion. The study included the OCP changes over time, measurements of Icorr, Ecorr and Rp as well as potentiodynamic examinations. Surface microstructure and chemical composition were analyzed using SEM and EDS methods. The results obtained allow us to conclude that the processes corresponding to ceramic oxidation and fusion on titanium in the variants used in the study do not cause deterioration of its anticorrosive properties, and partially enhance the resistance. This depends on the quality of oxide layers structure. Titanium elements treated by porcelain firing processes do not lose their corrosion resistance.
Aviation Engine Test Facilities (AETF) fire protection study
NASA Astrophysics Data System (ADS)
Beller, R. C.; Burns, R. E.; Leonard, J. T.
1989-07-01
An analysis is presented to the effectiveness of various types of fire fighting agents in extinguishing the kinds of fires anticipated in Aviation Engine Test Facilities (AETF), otherwise known as Hush Houses. The agents considered include Aqueous Film-Forming Foam, Halon 1301, Halon 1211 and water. Previous test work has shown the rapidity with which aircraft, especially high performance aircraft, can be damaged by fire. Based on this, tentative criteria for this evaluation included a maximum time of 20 s from fire detection to extinguishment and a period of 30 min in which the agent would prevent reignition. Other issues examined included: toxicity, corrosivity, ease of personnel egress, system reliability, and cost effectiveness. The agents were evaluated for their performance in several fire scenarios, including: under frame fire, major engine fire, engine disintegration fire, high-volume pool fire with simultaneous spill fire, internal electrical fire, and runaway engine fire.
FIRES: Fire Information Retrieval and Evaluation System - A program for fire danger rating analysis
Patricia L. Andrews; Larry S. Bradshaw
1997-01-01
A computer program, FIRES: Fire Information Retrieval and Evaluation System, provides methods for evaluating the performance of fire danger rating indexes. The relationship between fire danger indexes and historical fire occurrence and size is examined through logistic regression and percentiles. Historical seasonal trends of fire danger and fire occurrence can be...