Sample records for fire resistant panels

  1. Foam composite structures. [for fire retardant airframe materials

    NASA Technical Reports Server (NTRS)

    Delano, C. B.; Milligan, R. J.

    1976-01-01

    The need to include fire resistant foams into state of the art aircraft interior paneling to increase passenger safety in aircraft fires was studied. Present efforts were directed toward mechanical and fire testing of panels with foam inclusions. Skinned foam filled honeycomb and PBI structural foams were the two constructions investigated with attention being directed toward weight/performance/cost trade-off. All of the new panels demonstrated improved performance in fire and some were lighter weight but not as strong as the presently used paneling. Continued efforts should result in improved paneling for passenger safety. In particular the simple partial filling (fire side) of state-of-the-art honeycomb with fire resistant foams with little sacrifice in weight would result in panels with increased fire resistance. More important may be the retarded rate of toxic gas evolution in the fire due to the protection of the honeycomb by the foam.

  2. Fire Resistance of Large-Scale Cross-Laminated Timber Panels

    NASA Astrophysics Data System (ADS)

    Henek, Vladan; Venkrbec, Václav; Novotný, Miloslav

    2017-12-01

    Wooden structures are increasingly being used in the construction of residential buildings. A common and often published reason to avoid wooden structures is their insufficient fire resistance, which reduces bearing capacity. For this reason, composite sandwich structures began to be designed to eliminate this drawback, as well as others. Recently, however, the trend is for a return to the original, wood-only variant and a search is underway for new technical means of improving the properties of such structures. Many timber structure technologies are known, but structures made from cross-laminated timber (CLT) panels have been used very often in recent years. CLT panels, also known as X-LAM, are currently gaining popularity in Europe. In the case of CLT panels composed of several layers of boards, they can be said to offer a certain advantage in that after the surface layer of a board has burnt and the subsurface layer has dried, oxygen is not drawn to the unburned wood for further combustion and thus the burning process ceases. CLT panels do not need to be specially modified or coated with fire resistant materials, although they are usually lined with gypsum-fibre fire resistant boards due to guidelines set out in the relevant standards. This paper presents a new method for the assessment of load-bearing perimeter walls fabricated from CLT panels without the use of an inner fire-retardant lining to ensure fire resistance at the level required by European standards (i.e. those harmonized for the Czech construction industry). The calculations were verified through laboratory tests which show that better parameters can be achieved during the classification of structures from the fire resistance point of view. The aim of the article is to utilize the results of assessment and testing by an accredited laboratory in order to demonstrate the possibilities of using CLT panels for the construction of multistorey as well as multi-purpose buildings in the Czech Republic.

  3. Preparation for foam composites. [using polybenzimidazole for fireproofing panels

    NASA Technical Reports Server (NTRS)

    Maximovich, M. G.

    1974-01-01

    Methods were developed for the fabrication of fire resistant panels utilizing polybenzimidazole (PBI) and Kerimid 601 resins along with glass, quartz, and Kevlar reinforcements. Stitched truss structure, both unfilled and filled with PBI foam, were successfully fabricated and tested. Second generation structures were then selected, fabricated, and tested, with a PBI/glass skin/PBI foam sandwich structure emerging as the optimum panel concept. Mechanical properties, smoke generation, and fire resistance were determined for the candidate panels.

  4. Development of assembly techniques for fire resistant aircraft interior panels

    NASA Technical Reports Server (NTRS)

    Lee, S. C. S.

    1978-01-01

    Ten NASA Type A fire resistant aircraft interior panels were fabricated and tested to develop assembly techniques. These techiques were used in the construction of a full scale lavatory test structure for flame propagation testing. The Type A panel is of sandwich construction consisting of Nomex honeycomb filled with quinone dioxime foam, and bismaleimide/glass face sheets bonded to the core with polyimide film adhesive. The materials selected and the assembly techniques developed for the lavatory test structure were designed for obtaining maximum fire containment with minimum smoke and toxic emission.

  5. Development of lightweight fire retardant, low-smoke, high-strength, thermally stable aircraft floor paneling

    NASA Technical Reports Server (NTRS)

    Arnold, D. B.; Burnside, J. V.; Hajari, J. V.

    1976-01-01

    Fire resistance mechanical property tests were conducted on sandwich configurations composed of resin-fiberglass laminates bonded with adhesives to Nomex honeycomb core. The test results were compared to proposed and current requirements for aircraft floor panel applications to demonstrate that the fire safety of the airplane could be improved without sacrificing mechanical performance of the aircraft floor panels.

  6. Physical and mechanical properties and fire, decay, and termite resistance of treated oriented strandboard

    Treesearch

    Nadir Ayrilmis; S Nami Kartal; Theodore L. Laufenberg; Jerrold E. Winandy; Robert H. White

    2005-01-01

    This study evaluated the effects of a number of chemicals on the physical and mechanical properties and fire, decay, and termite resistance of oriented strandboard (OSB) panels. Disodium octaborate tetrahydrate (DOT), boric acid (BA), melamine phosphate (MP), and a BA/DOT mixture were sprayed onto the furnish at varying concentrations. The panels were tested for...

  7. Development of lightweight, fire-retardant, low-smoke, high-strength, thermally stable aircraft floor paneling

    NASA Technical Reports Server (NTRS)

    Anderson, R. A.; Ougland, R. M.; Karch, R. J.

    1978-01-01

    Extensive fire resistance and mechanical property tests were conducted on sandwich configurations composed of resin-fiberglass laminates bonded with adhesive to Nomex honeycomb and foam core. The test results were used to select a combination of materials that would improve the fire safety of the airplane without sacrificing mechanical performance of the aircraft floor panels. A test panel is being service evaluated in a commercial aircraft.

  8. Charring Rate for Fire Exposed X-Lam

    NASA Astrophysics Data System (ADS)

    Wong, Bernice VY; Fah Tee, Kong

    2017-06-01

    Design of timber structures has been outlined in Eurocode 5. Notional charring rate for softwood and hardwood timber is given. For the performance of X-LAM panels in fire, only little information on charring is available and whether the fire behaviour of X-LAM is similar to homogenous timber panels has not yet been systematically analysed. This paper presents an overview of fire performance of X-LAM and evaluation of its resistance to elevated temperature as an element of structure in comparison to homogeneous timber panels. Numerical study has been carried out based on available experimental results. Charring rates for X-LAM panels obtained from experimental results are compared with those obtained from Eurocode 5 and proposed simplified model.

  9. Lightweight, Fire-Resistant Graphite Composites

    NASA Technical Reports Server (NTRS)

    Kourtides, D. A.; Parker, J. A.; MING-TA-HSU

    1986-01-01

    Aircraft safety improved with interior paneling made of new laminate with good thermophysical properties. Featuring lightweight graphite composite, laminate more heat-and flame-resistant and produces much less smoke in fire than commonly used epoxy-resin-containing laminates. New laminate prepared without epoxy resin. Graphite unidirectional cloth preimpregnated with blend of vinyl polystyrylpyridine and bismaleimide (VPSP-BMI). Either of two types of VPSP-BMI blend used, depending on method of preparation of chemicals and technique used to fabricate panel.

  10. Structural wood panels with improved fire resistance

    NASA Technical Reports Server (NTRS)

    Sawko, P. M. (Inventor)

    1980-01-01

    Structural wood paneling or other molded wood compositions consisting of finely divided wood chips, flour, or strands are bound together and hot pressed with a modified novolac resin which is the cured product of a prepolymer made from an aralkyl ether or halide with a phenol and a hardening agent such as hexamethylene tetramine. The fire resistance of these articles is further improved by incorporating in the binder certain inorganic fillers, especially a mixture of ammonium oxalate and ammonium phosphate.

  11. Fire containment tests of aircraft interior panels

    NASA Technical Reports Server (NTRS)

    Kourtides, D. A.; Parker, J. A.; Leon, H. A.; Williamson, R. B.; Hasegawa, H.; Fisher, F.; Draemel, R.; Marcussen, W. H.; Hilado, C. J.

    1976-01-01

    The paper describes an experimental program carried out to evaluate a possible method for testing the fire-containment qualities of aircraft interior panels. The experimental apparatus consisted of a burner that simulates various fire loads under different ventilation conditions in an enclosure of approximately the same size as an aircraft lavatory module. Two fire-containment tests are discussed in which two adjoining walls of the enclosure were made from state-of-the-art composite panels; rats were exposed to the combustion products in order to evaluate the toxic threat posed by those products. The results show that the burner can be employed to represent various fire-load conditions and that the methodology developed for fire containment can be useful in evaluating the fire resistance of composite panels before conducting large-scale tests. It is concluded that elements of the fire-containment criteria include the temperature rise on the backface of the panels as a function of time, the flame burn-through by either decomposition or severe distortion of the material, and the toxicity of the combustion gases evolved.

  12. Influence of reinforcement type on the mechanical behavior and fire response of hybrid composites and sandwich structures

    NASA Astrophysics Data System (ADS)

    Giancaspro, James William

    Lightweight composites and structural sandwich panels are commonly used in marine and aerospace applications. Using carbon, glass, and a host of other high strength fiber types, a broad range of laminate composites and sandwich panels can be developed. Hybrid composites can be constructed by laminating multiple layers of varying fiber types while sandwich panels are manufactured by laminating rigid fiber facings onto a lightweight core. However, the lack of fire resistance of the polymers used for the fabrication remains a very important problem. The research presented in this dissertation deals with an inorganic matrix (Geopolymer) that can be used to manufacture laminate composites and sandwich panels that are resistant up to 1000°C. This dissertation deals with the influence of fiber type on the mechanical behavior and the fire response of hybrid composites and sandwich structures manufactured using this resin. The results are categorized into the following distinct studies. (i) High strength carbon fibers were combined with low cost E-glass fibers to obtain hybrid laminate composites that are both economical and strong. The E-glass fabrics were used as a core while the carbon fibers were placed on the tension face and on both tension and compression faces. (ii) Structural sandwich beams were developed by laminating various types of reinforcement onto the tension and compression faces of balsa wood cores. The flexural behavior of the beams was then analyzed and compared to beams reinforced with organic composite. The effect of core density was evaluated using oak beams reinforced with inorganic composite. (iii) To measure the fire response, balsa wood sandwich panels were manufactured using a thin layer of a fire-resistant paste to serve for fire protection. Seventeen sandwich panels were fabricated and tested to measure the heat release rates and smoke-generating characteristics. The results indicate that Geopolymer can be effectively used to fabricate both high strength composite plates and sandwich panels. A 2 mm thick coating of fireproofing on balsa wood is sufficient to satisfy FAA fire requirements.

  13. Development of aircraft lavatory compartments with improved fire resistance characteristics, phase 1: Fire containment test of a wide body aircraft lavatory module

    NASA Technical Reports Server (NTRS)

    Anderson, R. A.; Arnold, D. B.; Johnson, G. A.; Tustin, E. A.

    1978-01-01

    A test was conducted to evaluate the fire containment characteristics of a Boeing 747 lavatory module. Results showed that the fire was contained within the lavatory during the 30-minute test period with the door closed. The resistance of the lavatory wall and ceiling panels and general lavatory construction to burn-through under the test conditions was demonstrated.

  14. High temperature structural sandwich panels

    NASA Astrophysics Data System (ADS)

    Papakonstantinou, Christos G.

    High strength composites are being used for making lightweight structural panels that are being employed in aerospace, naval and automotive structures. Recently, there is renewed interest in use of these panels. The major problem of most commercial available sandwich panels is the fire resistance. A recently developed inorganic matrix is investigated for use in cases where fire and high temperature resistance are necessary. The focus of this dissertation is the development of a fireproof composite structural system. Sandwich panels made with polysialate matrices have an excellent potential for use in applications where exposure to high temperatures or fire is a concern. Commercial available sandwich panels will soften and lose nearly all of their compressive strength temperatures lower than 400°C. This dissertation consists of the state of the art, the experimental investigation and the analytical modeling. The state of the art covers the performance of existing high temperature composites, sandwich panels and reinforced concrete beams strengthened with Fiber Reinforced Polymers (FRP). The experimental part consists of four major components: (i) Development of a fireproof syntactic foam with maximum specific strength, (ii) Development of a lightweight syntactic foam based on polystyrene spheres, (iii) Development of the composite system for the skins. The variables are the skin thickness, modulus of elasticity of skin and high temperature resistance, and (iv) Experimental evaluation of the flexural behavior of sandwich panels. Analytical modeling consists of a model for the flexural behavior of lightweight sandwich panels, and a model for deflection calculations of reinforced concrete beams strengthened with FRP subjected to fatigue loading. The experimental and analytical results show that sandwich panels made with polysialate matrices and ceramic spheres do not lose their load bearing capability during severe fire exposure, where temperatures reach several hundred degrees Centigrade. Hence the material has excellent potential for various types of applications. The analytical predictions from both models provide reasonably accurate results. Glass, AR-glass, carbon and Nicalon tows and carbon fabrics could be successfully used as skin reinforcements increasing the flexural stiffness and strength of the core. No occurrence of fiber delamination was observed.

  15. Fire Resistance of Geopolymer Concretes

    DTIC Science & Technology

    2010-03-21

    1 Project report – Grant FA23860814096, "Fire resistance of geopolymer concretes" – J. Provis, University of Melbourne 1. Background and...experimental program This project provided funding for us to carry out fire testing of geopolymer concrete specimens and associated laboratory...testing. The focus of this report will be the outcomes of the series of pilot-scale (4’×4’×6”) tests on geopolymer concrete panels, which were conducted

  16. Fabrication and testing of fire resistant graphite composite panels

    NASA Technical Reports Server (NTRS)

    Roper, W. D.

    1986-01-01

    Eight different graphite composite panels were fabricated using four different resin matrices. The resin matrices included Hercules 71775, a blend of vinylpolystyrpyridine and bismaleimide, H795, a bismaleimide, Cycom 6162, a phenolic, and PSP 6022m, a polystyrylpyridine. Graphite panels were fabricated using fabric or unidirectional tape. Described are the processes for preparing these panels and some of their mechanical, thermal and flammability properties. Panel properties are compared with state-of-the-art epoxy fiberglass composite panels.

  17. Development of fire-resistant, low smoke generating, thermally stable end items for commercial aircraft and spacecraft using a basic polyimide resin

    NASA Technical Reports Server (NTRS)

    Gagliani, J.; Lee, R.; Sorathia, U. A.; Wilcoxson, A. L.

    1980-01-01

    A terpolyimide precursor was developed which can be foamed by microwave methods and yields foams possessing the best seating properties. A continuous process, based on spray drying techniques, permits production of polyimide powder precursors in large quantities. The constrained rise foaming process permits fabrication of rigid foam panels with improved mechanical properties and almost unlimited density characteristics. Polyimide foam core rigid panels were produced by this technique with woven fiberglass fabric bonded to each side of the panel in a one step microwave process. The fire resistance of polyimide foams was significantly improved by the addition of ceramic fibers to the powder precursors. Foams produced from these compositions are flexible, possess good acoustical attenuation and meet the minimum burnthrough requirements when impinged by high flux flame sources.

  18. Federal Aviation Administration Plan for Research, Engineering & Development, 1998.

    DTIC Science & Technology

    1998-02-01

    release rate. • Improved fracture toughness of non-combustible geopolymer composite fire barriers to enable use as interior and secondary composites ...Fire Resistant, Non-Toxic Interior Panels for Evaluation of Heat Release Rate ♦ Improved Fracture Toughness of Non-Combustible Geopolymer Composite ... composites , atmospheric hazards, crash worthiness, fire safety, and forensics capabilities to support accident investigations. Aviation Security R,E&D

  19. Development of fire-resistant wood structural panels

    NASA Technical Reports Server (NTRS)

    Vaughan, T. W.; Etzold, R.

    1977-01-01

    Structural panels made with Xylok 210 resin as the binder had a burn-through resistance at least equal to the structural panels made with Kerimid 500. Therefore, because of its comparative ease of handling, Xylok 210 was selected as the resin binder to provide the baseline panel for the study of a means of improving the flame-spread resistance of the structural panels. The final resin-filler system consisted of Xylok 210 binder with the addition of ammonium oxalate and ammonium phosphate to the strands of the surface layers, using 24% of each salt based upon the air-dry weight of the strands. This system resulted in a panel with a flame-spread code of about 60, a Class 2 classification. A standard phenolic based structural panel had a flame-spread greater than 200 for laboratory prepared panels. The burn-through tests indicated an average burn-through time of 588 seconds for the specimens made with the final system. This compares to an average burn-through time of 287 seconds for the standard phenolic base structural specimen. One full-size panel was made with the final system.

  20. The optimization of aircraft seat cushion fire-blocking layers. Full Scale: Test description and results

    NASA Technical Reports Server (NTRS)

    Schutter, K. J.; Duskin, F. E.

    1982-01-01

    Full-scale burn tests were conducted on thirteen different seat cushion configurations in a cabin fire simulator. The fire source used was a quartz lamp radiant energy panel with a propane pilot flame. During each test, data were recorded for cushion temperatures, radiant heat flux, rate of weight loss of test specimens, and cabin temperatures. When compared to existing passenger aircraft seat cushions, the test specimens incorporating a fire barrier and those fabricated from advance materials, using improved construction methods, exhibited significantly greater fire resistance.

  1. Preparation, testing, and delivery of low density polyimide foam panels

    NASA Technical Reports Server (NTRS)

    Ball, G. L., III; Post, L. K.; Salyer, I. O.

    1975-01-01

    Plastic foams based on polyimide resins were shown to be stable at relatively high temperatures, and to possess very low flame spread and smoke generation characteristics. A system and process were developed to prepare low-density polyimide foam from a liquid formulation. The system is based on the reaction of micropulverized grade pyromellitic dianhydride with a polymeric diisocyanate. The panels produced were postcured at elevated temperatures to achieve maximum thermal and fire resistance, and incorporation of a fire retardant into the formulation was considered. The effects of a flame retardant (Flameout 5600B1) were investigated, but eliminated in preference to the postcuring approach.

  2. Development of fire-resistant, low smoke generating, thermally stable end items for aircraft and spacecraft

    NASA Technical Reports Server (NTRS)

    Gagliani, J.

    1978-01-01

    A new approach to the problem of flammability by the use of materials obtained from foamy polyimide resins is developed. The ability of these materials to provide fire protection is demonstrated. The development of processes for producing resilient cell foam for use in aircraft seating, thermal acoustical insulation, floor and wall panels, coated glass fabrics, and molded hardware.

  3. Fireproofing and heat insulating performance improvement of EG/ATH modified intumescent flame retardant coating treated under Co-60 radiation

    NASA Astrophysics Data System (ADS)

    Zhang, Yuehong; Luan, Weiling; Jiang, Tao

    2017-12-01

    New intumescent flame retardant (IFR) coatings with different fire retardants were prepared in this paper. Expandable graphite (EG) and Aluminium hydroxide (ATH) were respectively added into the conventional IFR coating system, which included ammonium polyphosphate (APP) / pentaerythritol (PER) / melamine (MEL). The fireproofing time and heat insulating properties of the additives acted as fire retardants were investigated via thermogravimetry analysis (TGA) and fire resistance test of homemade big panel test. The morphology of the char layer structure was achieved by scanning electron microscopy (SEM). The highlight of the paper was that the coating samples were pretreated under Co-60 radiation. The influence of radiation on the fire resistance time and char layer height was investigated. The results showed that the prepared IFR coatings can be used in Co-60 radiation for more than 90 min when encountering fire. It would be a reference for radiation shielding in nuclear environment.

  4. Development of aircraft lavatory compartments with improved fire resistance characteristics. Phase 2: Sandwich panel resin system development

    NASA Technical Reports Server (NTRS)

    Anderson, R. A.; Arnold, D. B.; Johnson, G. A.

    1979-01-01

    A NASA-funded program is described which aims to develop a resin system for use in the construction of lavatory wall panels, sidewall panels, and ceiling panels possessing flammability, smoke and gas emission, and toxicity (FS&T) characteristics superior to the existing epoxy resin. Candidate resins studied were phenolic, polyimide, and bismaleimide. Based on the results of a series of FS&T as well as mechanical and aesthetic property tests, a phenolic resin was chosen as the superior material. Material and process specifications covering the phenolic resin based materials were prepared and a method of rating sandwich panel performance was developed.

  5. Development of fire-resistant, low smoke generating, thermally stable end items for aircraft and spacecraft

    NASA Technical Reports Server (NTRS)

    Gagliani, J.; Sorathia, U. A. K.; Wilcoxson, A. L.

    1977-01-01

    Materials were developed to improve aircraft interior materials by modifying existing polymer structures, refining the process parameters, and by the use of mechanical configurations designed to overcome specific deficiencies. The optimization, selection, and fabrication of five fire resistant, low smoke emitting open cell foams are described for five different types of aircraft cabin structures. These include: resilient foams, laminate floor and wall paneling, thermal/acoustical insulation, molded shapes, and coated fabrics. All five have been produced from essentially the same polyimide precursor and have resulted in significant benefits from transfer of technology between the various tasks.

  6. Development of a protective decorative fire resistant low smoke emitting, thermally stable coating material

    NASA Technical Reports Server (NTRS)

    1976-01-01

    The development of suitable electrocoatings and subsequent application to nonconductive substrates are discussed. Substrates investigated were plastics or resin-treated materials such as FX-resin (phenolic-type resin) impregnated fiberglass mat, polyphenylene sulfide, polyether sulfone and polyimide-impregnated unidirectional fiberglass. Efforts were aimed at formulating a fire-resistant, low smoke emitting, thermally stable, easily cleaned coating material. The coating is to be used for covering substrate panels, such as aluminum, silicate foam, polymeric structural entities, etc., all of which are applied in the aircraft cabin interior and thus subject to the spillages, scuffing, spotting and the general contaminants which prevail in aircraft passenger compartments.

  7. Study of thermal stability and degradation of fire resistant candidate polymers for aircraft interiors

    NASA Technical Reports Server (NTRS)

    Hsu, M. T. S.

    1976-01-01

    The thermochemistry of bismaleimide resins and phenolphthalein polycarbonate was studied. Both materials are fire-resistant polymers and may be suitable for aircraft interiors. The chemical composition of the polymers has been determined by nuclear magnetic resonance and infrared spectroscopy and by elemental analysis. Thermal properties of these polymers have been characterized by thermogravimetric analyses. Qualitative evaluation of the volatile products formed in pyrolysis under oxidative and non-oxidative conditions has been made using infrared spectrometry. The residues after pyrolysis were analyzed by elemental analysis. The thermal stability of composite panel and thermoplastic materials for aircraft interiors was studied by thermogravimetric analyses.

  8. Fire resistant films for aircraft applications

    NASA Technical Reports Server (NTRS)

    Kourtides, D. A.

    1983-01-01

    Alternative sandwich panel decorative films were investigated as replacements for the polyvinyl fluoride currently used in aircraft interiors. Candidate films were studied for flammability, smoke emission, toxic gas emission, flame spread, and suitability as a printing surface for the decorative acrylic ink system. Several of the candidate films tested were flame modified polyvinyl fluoride, polyvinylidene fluoride, polyimide, polyamide, polysulfone, polyphenylsulfone, polyethersulfone, polybenzimidazole, polycarbonate, polyparabanic acid, polyphosphazene, polyetheretherketon, and polyester. The films were evaluated as pure films only, films silk-screened with an acrylic ink, and films adhered to a phenolic fiberglass substrate. Films which exhibited the highest fire resistant properties included PEEK polyetheretherketon, Aramid polyamide, and ISO-BPE polyester.

  9. Development of aircraft lavatory compartments with improved fire resistance characteristics. Phase 4: Sandwich panel decorative ink development

    NASA Technical Reports Server (NTRS)

    Jayarajan, A.; Johnson, G. A.; Korver, G. L.; Anderson, R. A.

    1983-01-01

    Five chemically different resin systems with improved fire resistance properties were studied for a possible screenprinting ink application. Fire resistance is hereby defined as the cured ink possessing improvements in flammability, smoke emission, and thermal stability. The developed ink is for application to polyvinyl fluoride film. Only clear inks without pigments were considered. Five formulations were evaluated compared with KC4900 clear acrylic ink, which was used as a baseline. The tests used in the screening evaluation included viscosity, smoke and toxic gas emission, limiting oxygen index (LOI), and polyvinyl fluoride film (PVF) printability. A chlorofluorocarbon resin (FPC461) was selected for optimization studies. The parameters for optimization included screenprinting process performance, quality of coating, and flammability of screenprinted 0.051-mm (0.002-in.) white Tedlar. The quality of the screenprinted coating on Tedlar is dependent on viscosity, curing time, adhesion to polyvinyl fluoride film, drying time (both inscreen and as an applied film), and silk screen mesh material and porosity.

  10. 78 FR 34335 - Foreign-Trade Zone (FTZ) 141-Monroe County, New York; Notification of Proposed Production...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-07

    ... steel, fire and water resistant storage chests, gun safes, security safes, portable security safes, cash..., touchpads, plastic gun racks, keypad assemblies, panel lock assemblies, door backs, plastic trays, drawers..., wood gun shelf racks, cable assemblies, communication cables, gasket kits, door springs, metal handles...

  11. Overview of FIREMEN program at Ames Research Center

    NASA Technical Reports Server (NTRS)

    Kourtides, D. A.

    1978-01-01

    The Ames Firemen Program is described. The key elements of the program include: (1) the development and evaluation of aircraft interior composite panels; (2) the thermochemical and flammability characterization of thermoset and thermoplastic resins; and (3) the evolution of fire resist aircraft seat components. The first two elements are presented.

  12. Fire-Resistant Composites

    NASA Technical Reports Server (NTRS)

    Kourtides, D. A.; Parker, J. A.

    1983-01-01

    Resin blend produces high-char-yield, low-smoke composites. Diglycidyl Ether of Bis-(4-Hydroxyphenyl)-Fluorene is prepared by reacting epichlorohydrin and sodium hydroxide with 9,9-bis(hydroxyphenyl) fluorene. End of reaction determined by gas or liquid chromatography, mass spectroscopy or infrared techniques. Used to manufacture printed circuit boards and panels for buildings, ships and aircraft.

  13. Numerical Simulation of Thermal Performance of Glass-Fibre-Reinforced Polymer

    NASA Astrophysics Data System (ADS)

    Zhao, Yuchao; Jiang, Xu; Zhang, Qilin; Wang, Qi

    2017-10-01

    Glass-Fibre-Reinforced Polymer (GFRP), as a developing construction material, has a rapidly increasing application in civil engineering especially bridge engineering area these years, mainly used as decorating materials and reinforcing bars for now. Compared with traditional construction material, these kinds of composite material have obvious advantages such as high strength, low density, resistance to corrosion and ease of processing. There are different processing methods to form members, such as pultrusion and resin transfer moulding (RTM) methods, which process into desired shape directly through raw material; meanwhile, GFRP, as a polymer composite, possesses several particular physical and mechanical properties, and the thermal property is one of them. The matrix material, polymer, performs special after heated and endue these composite material a potential hot processing property, but also a poor fire resistance. This paper focuses on thermal performance of GFRP as panels and corresponding researches are conducted. First, dynamic thermomechanical analysis (DMA) experiment is conducted to obtain the glass transition temperature (Tg) of the object GFRP, and the curve of bending elastic modulus with temperature is calculated according to the experimental data. Then compute and estimate the values of other various thermal parameters through DMA experiment and other literatures, and conduct numerical simulation under two condition respectively: (1) the heat transfer process of GFRP panel in which the panel would be heated directly on the surface above Tg, and the hot processing under this temperature field; (2) physical and mechanical performance of GFRP panel under fire condition. Condition (1) is mainly used to guide the development of high temperature processing equipment, and condition (2) indicates that GFRP’s performance under fire is unsatisfactory, measures must be taken when being adopted. Since composite materials’ properties differ from each other and their high temperature parameters can’t be obtained through common methods, some parameters are estimated, the simulation is to guide the actual high temperature experiment, and the parameters will also be adjusted by then.

  14. Hybridized polymer matrix composites

    NASA Technical Reports Server (NTRS)

    Henshaw, J.

    1983-01-01

    Methods of improving the fire resistance of graphite epoxy composite laminates were investigated with the objective of reducing the volume of loose graphite fibers disseminated into the airstream as the result of a high intensity aircraft fuel fire. Improvements were sought by modifying the standard graphite epoxy systems without significantly negating their structural effectiveness. The modifications consisted primarily of an addition of a third constituent material such as glass fibers, glass flakes, carbon black in a glassy resin. These additions were designed to encourage coalescense of the graphite fibers and thereby reduce their aerodynamic float characteristics. A total of 38 fire tests were conducted on thin (1.0 mm) and thick (6.0 mm) hybrid panels.

  15. Development of porcelain enamel passive thermal control coatings

    NASA Technical Reports Server (NTRS)

    Levin, H.; Lent, W. E.; Buettner, D. H.

    1973-01-01

    A white porcelain enamel coating was developed for application to high temperature metallic alloy substrates on spacecraft. The coating consists of an optically opacifying zirconia pigment, a lithia-zirconia-silica frit, and an inorganic pigment dispersant. The coating is fired at 1000 to 1150 C to form the enamel. The coating has a solar absorptance of 0.22 and a total normal emittance of 0.82 for a 0.017 cm thick coating. The coating exhibits excellent adhesion, cleanability, and integrity and is thermal shock resistant to 900 C. Capability to coat large panels has been demonstrated by successful coating of 30 cm x 30 cm Hastelloy X alloy panels. Preliminary development of low temperature enamels for application to aluminum and titanium alloy substrates was initiated. It was determined that both leaded and leadless frits were feasible when applied with appropriate mill fluxes. Indications were that opacification could be achieved at firing temperatures below 540 C for extended periods of time.

  16. Improved Mechanical Properties of Various Fabric-Reinforced Geocomposite at Elevated Temperature

    NASA Astrophysics Data System (ADS)

    Samal, Sneha; Phan Thanh, Nhan; Petríková, Iva; Marvalová, Bohadana

    2015-07-01

    This article signifies the improved performance of the various types of fabric reinforcement of geopolymer as a function of physical, thermal, mechanical, and heat-resistant properties at elevated temperatures. Geopolymer mixed with designed Si:Al ratios of 15.6 were synthesized using three different types of fabric reinforcement such as carbon, E-glass, and basalt fibers. Heat testing was conducted on 3-mm-thick panels with 15 × 90 mm surface exposure region. The strength of carbon-based geocomposite increased toward a higher temperature. The basalt-reinforced geocomposite strength decreased due to the catastrophic failure in matrix region. The poor bridging effect and dissolution of fabric was observed in the E-glass-reinforced geocomposite. At an elevated temperature, fiber bridging was observed in carbon fabric-reinforced geopolymer matrix. Among all the fabrics, carbon proved to be suitable candidate for the high-temperature applications in thermal barrier coatings and fire-resistant panels.

  17. Measurements of the response of transport aircraft ceiling panels to fuel pool fires

    NASA Technical Reports Server (NTRS)

    Bankston, C. P.; Back, L. H.

    1985-01-01

    Tests were performed to characterize the responses of various aircraft ceiling panel configurations to a simulated post-crash fire. Attention was given to one currently used and four new ceiling configurations exposed to a fuel pool fire in a circulated air enclosure. The tests were controlled to accurately represent conditions in a real fire. The panels were constructed of fiberglass-epoxy, graphite-phenolic resin, fiberglass-phenolic resin, Kevlar-epoxy, and Kevlar-phenolic resin materials. The phenolic resin-backed sheets performed the best under the circumstances, except when combined with Kevlar, which became porous when charred.

  18. Thermal Insulation

    NASA Technical Reports Server (NTRS)

    1984-01-01

    Commercially known as Solimide, Temptronics, Inc.'s thermal insulation has application in such vehicles as aircraft, spacecraft and surface transportation systems (i.e. rapid transit cars, trains, buses, and ships) as acoustical treatment for door, wall, and ceiling panels, as a means of reducing vibrations, and as thermal insulation (also useful in industrial equipment). Product originated from research conducted by Johnson Space Center on advanced flame-resistant materials for minimizing fire hazard in the Shuttle and other flight vehicles.

  19. Development of photovoltaic array and module safety requirements

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Safety requirements for photovoltaic module and panel designs and configurations likely to be used in residential, intermediate, and large-scale applications were identified and developed. The National Electrical Code and Building Codes were reviewed with respect to present provisions which may be considered to affect the design of photovoltaic modules. Limited testing, primarily in the roof fire resistance field was conducted. Additional studies and further investigations led to the development of a proposed standard for safety for flat-plate photovoltaic modules and panels. Additional work covered the initial investigation of conceptual approaches and temporary deployment, for concept verification purposes, of a differential dc ground-fault detection circuit suitable as a part of a photovoltaic array safety system.

  20. Analysis of the Influence of Construction Insulation Systems on Public Safety in China

    PubMed Central

    Zhang, Guowei; Zhu, Guoqing; Zhao, Guoxiang

    2016-01-01

    With the Government of China’s proposed Energy Efficiency Regulations (GB40411-2007), the implementation of external insulation systems will be mandatory in China. The frequent external insulation system fires cause huge numbers of casualties and extensive property damage and have rapidly become a new hot issue in construction evacuation safety in China. This study attempts to reconstruct an actual fire scene and propose a quantitative risk assessment method for upward insulation system fires using thermal analysis tests and large eddy simulations (using the Fire Dynamics Simulator (FDS) software). Firstly, the pyrolysis and combustion characteristics of Extruded polystyrene board (XPS panel), such as ignition temperature, combustion heat, limiting oxygen index, thermogravimetric analysis and thermal radiation analysis were studied experimentally. Based on these experimental data, large eddy simulation was then applied to reconstruct insulation system fires. The results show that upward insulation system fires could be accurately reconstructed by using thermal analysis test and large eddy simulation. The spread of insulation material system fires in the vertical direction is faster than that in the horizontal direction. Moreover, we also find that there is a possibility of flashover in enclosures caused by insulation system fires as the smoke temperature exceeds 600 °C. The simulation methods and experimental results obtained in this paper could provide valuable references for fire evacuation, hazard assessment and fire resistant construction design studies. PMID:27589774

  1. Analysis of the Influence of Construction Insulation Systems on Public Safety in China.

    PubMed

    Zhang, Guowei; Zhu, Guoqing; Zhao, Guoxiang

    2016-08-30

    With the Government of China's proposed Energy Efficiency Regulations (GB40411-2007), the implementation of external insulation systems will be mandatory in China. The frequent external insulation system fires cause huge numbers of casualties and extensive property damage and have rapidly become a new hot issue in construction evacuation safety in China. This study attempts to reconstruct an actual fire scene and propose a quantitative risk assessment method for upward insulation system fires using thermal analysis tests and large eddy simulations (using the Fire Dynamics Simulator (FDS) software). Firstly, the pyrolysis and combustion characteristics of Extruded polystyrene board (XPS panel), such as ignition temperature, combustion heat, limiting oxygen index, thermogravimetric analysis and thermal radiation analysis were studied experimentally. Based on these experimental data, large eddy simulation was then applied to reconstruct insulation system fires. The results show that upward insulation system fires could be accurately reconstructed by using thermal analysis test and large eddy simulation. The spread of insulation material system fires in the vertical direction is faster than that in the horizontal direction. Moreover, we also find that there is a possibility of flashover in enclosures caused by insulation system fires as the smoke temperature exceeds 600 °C. The simulation methods and experimental results obtained in this paper could provide valuable references for fire evacuation, hazard assessment and fire resistant construction design studies.

  2. 124. FIRE ALARM SYSTEM PANEL AT WEST SIDE OF SOUTH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    124. FIRE ALARM SYSTEM PANEL AT WEST SIDE OF SOUTH WALL, TRANSFORMER ROOM (112), LSB (BLDG. 770) - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  3. 77. Deputy commander's launch control console, fire control panel missing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    77. Deputy commander's launch control console, fire control panel missing at right, south side - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  4. Prefabricated Refractory Panels for Use in KSC's Flame Deflectors: A Feasibility Study

    NASA Technical Reports Server (NTRS)

    Calle, Luz Maria; Trejo, David

    2010-01-01

    The launch complexes at the John F. Kennedy Space Center (KSC) have been used to launch space vehicles for the Apollo and Space Shuttle programs. NASA is currently designing and developing a new space vehicle. The launch complexes have been in service for a significant duration and the aggressive conditions of the Florida coast and the launches have resulted in failures within the launch complexes. Of particular interests is the performance of the refractory lining that covers the steel base structure for the diversion of the exhaust from the launched vehicles (i.e., the flame deflectors). An unprotected steel base structure would likely experience loss of strength and possible failure when subjected to the high temperatures during launches. The refractory lining is critical for successful launches. The refractory material currently used in the flame trenches was developed in 1959 and is the only refractory material approved for use in these facilities. Significant effort and costs are expended in repairing the lining system after each launch. NASA is currently performing a comprehensive research program to assess and develop refractory materials for improved performance in the flame trenches. However, one challenge associated with the use of refractory materials in the flame trench is that the materials should be cured, dried, and fired to maximize their properties and characteristics. Because of the large size of the deflectors and trenches, drying and firing of the lining system is difficult, if not impossible. Most refractory materials are dried and fired before use. Because the refractory materials used for the deflector lining cannot be dried and fired, the full potential of the materials are not being realized. A system that could use refractory materials that could be cured, dried, and sintered in a controlled environment would likely improve the performance of the lining system. This report evaluates the feasibility of fabricating and placing prefabricated refractory panels on the deflector. Panels could be fabricated and processed off-site in a controlled environment to maximize performance. These panels could then be transported to KSC and installed on the flame deflector. The findings of this report indicate that conventionally reinforced, prefabricated refractory panels can likely be designed, fabricated, and placed on the deflector. Post-tensioning of the panels will reduce the amount of "open' joints, which can be susceptible to accelerated erosion and abrasion. The panels, produced with newer, better performing refractory materials, should exhibit lower deterioration, providing a more economical system. A method for placing the panels has been provided. The findings of this research indicate that post-tensioned, prefabricated refractory panels can be placed on the flame deflectors and should exhibit improved performance when compared with the current method of gunning the refractories on the deflector. Further evaluation will be needed to confirm these findings. Specific focus should be placed on the performance of the joints transverse to the exhaust flow, erosion/abrasion rates of "closed" joints, uplift forces at joints transverse to the exhaust flow, development of composite action between the steel base and the refractory panels, and refractory material resistance to the launch and Florida coast environment.

  5. Behavior of sandwich panels in a fire

    NASA Astrophysics Data System (ADS)

    Chelekova, Eugenia

    2018-03-01

    For the last decades there emerged a vast number of buildings and structures erected with the use of sandwich panels. The field of application for this construction material is manifold, especially in the construction of fire and explosion hazardous buildings. In advanced evacu-ation time calculation methods the coefficient of heat losses is defined with dire regard to fire load features, but without account to thermal and physical characteristics of building envelopes, or, to be exact, it is defined for brick and concrete walls with gross heat capacity. That is why the application of the heat loss coefficient expression obtained for buildings of sandwich panels is impossible because of different heat capacity of these panels from the heat capacities of brick and concrete building envelopes. The article conducts an analysis and calculation of the heal loss coefficient for buildings and structures of three layer sandwich panels as building envelopes.

  6. Evaluation of the FilmArray Blood Culture Identification Panel: Results of a Multicenter Controlled Trial

    PubMed Central

    Salimnia, Hossein; Lephart, Paul R.; Schreckenberger, Paul; DesJarlais, Sharon M.; Johnson, J. Kristie; Robinson, Gwen; Carroll, Karen C.; Greer, Amy; Morgan, Margie; Chan, Raymond; Loeffelholz, Michael; Valencia-Shelton, Frances; Jenkins, Stephen; Schuetz, Audrey N.; Daly, Judy A.; Barney, Trenda; Hemmert, Andrew; Kanack, Kristen J.

    2016-01-01

    Sepsis is a major cause of morbidity, mortality, and increased medical expense. Rapid diagnosis improves outcomes and reduces costs. The FilmArray blood culture identification panel (BioFire Diagnostics LLC, Salt Lake City, UT), a highly multiplexed PCR assay, can identify 24 etiologic agents of sepsis (8 Gram-positive, 11 Gram-negative, and 5 yeast species) and three antimicrobial resistance genes (mecA, vanA/B, and blaKPC) from positive blood culture bottles. It provides results in about 1 h with 2 min for assay setup. We present the results of an eight-center trial comparing the sensitivity and specificity of the panel with those of the laboratories' standard phenotypic identification techniques, as well as with molecular methods used to distinguish Acinetobacter baumannii from other members of the A. calcoaceticus-A. baumannii complex and to detect antimicrobial resistance genes. Testing included 2,207 positive aerobic blood culture samples, 1,568 clinical and 639 seeded. Samples were tested fresh or were frozen for later testing within 8 h after the bottles were flagged as positive by an automated blood culture system. At least one organism was detected by the panel in 1,382 (88.1%) of the positive clinical specimens. The others contained primarily off-panel organisms. The panel reported multiple organisms in 81 (5.86%) positive clinical specimens. The unresolved blood culture identification sensitivity for all target detections exceeded 96%, except for Klebsiella oxytoca (92.2%), which achieved 98.3% sensitivity after resolution of an unavoidable phenotypic error. The sensitivity and specificity for vanA/B and blaKPC were 100%; those for mecA were 98.4 and 98.3%, respectively. PMID:26739158

  7. USGS Wildland Fire Workshop, EROS Data Center, Sioux Falls, SD, July 9-10, 1997.

    DTIC Science & Technology

    1998-04-01

    Montana , began by providing a brief over- view of research done at the U.S. Forest Service laborato- ries in East Lansing, Michigan and Seattle...Ecology and Fire Effects Panel; the Modeling: Fire Spread, Smoke Plume Panel; and the Postfire Rehabilitation, Hazards Assessment, and Habitat ...endangered species and criti- cal biological habitats . Ongoing research also is evaluat- ing the influences of seasonal burns, frequency of burns

  8. Power packs: A passive approach to extinguishing fire in combat vehicles

    NASA Astrophysics Data System (ADS)

    Finnerty, Anthony E.; Polyanski, Stanley

    1991-01-01

    Thin (12.7 and 6.4 mm) panels of fire extinguishing powder in a honeycomb matrix were tested for their ability to extinguish fires in the FAASV ammunition resupply vehicle. These powder packs were applied to the exterior of hydraulic fluid reservoirs and fuel cells for protection from hydrocarbon fires caused by shaped charge jets penetrating the fluid containers. It was found that a surround of 12.7-mm-thick panels was required to achieve a sub 250-ms fire-out time with no second-degree burns expected to personnel with hot hydraulic fluid reservoirs. Power packs as thin as 6.4 mm provided the same protection in the case of hot diesel fuel.

  9. Study to develop improved fire resistant aircraft passenger seat materials

    NASA Technical Reports Server (NTRS)

    Duskin, F. E.; Schutter, K. J.; Sieth, H. H.; Trabold, E. L.

    1980-01-01

    The Phase 3 study of the NASA 'Improved Fire Resistant Aircraft Seat Materials' involved fire tests of improved materials in multilayered combinations representative of cushion configurations. Tests were conducted to determine their thermal, smoke, and fire resistance characteristics. Additionally, a 'Design Guideline' for Fire Resistant Passenger Seats was written outlining general seat design considerations. Finally, a three-abreast 'Tourist Class' passenger seat assembly fabricated from the most advanced fire-resistant materials was delivered.

  10. Development of Polyimide Foam for Aircraft Sidewall Applications

    NASA Technical Reports Server (NTRS)

    Silcox, Richard; Cano, Roberto J.; Howerton, Brian M.; Bolton, J. Stuart; Kim, Nicholas N.

    2013-01-01

    In this paper, the use of polyimide foam as a lining in double panel applications is considered. It is being investigated here as a replacement for aircraft grade glass fiber and has a number of attractive functional attributes, not the least of which is its high fire resistance. The test configuration studied here consisted of two 1mm (0.04 in.) thick, flat aluminum panels separated by 12.7 cm (5.0 in.) with a 7.6 cm (3.0 in.) thick layer of foam centered in that space. Random incidence transmission loss measurements were conducted on this buildup, and conventional poro-elastic models were used to predict the performance of the lining material. Results from two densities of foam are considered. The Biot parameters of the foam were determined by a combination of direct measurement (for density, flow resistivity and Young s modulus) and inverse characterization procedures (for porosity, tortuosity, viscous and thermal characteristic length, Poisson s ratio and loss factor). The inverse characterization procedure involved matching normal incidence standing wave tube measurements of absorption coefficient and transmission loss of the isolated foam with finite element predictions. When the foam parameters determined in this way were used to predict the performance of the complete double panel system, reasonable agreement was obtained between the measured transmission loss and predictions made using a commercial statistical energy analysis code.

  11. Full-scale aircraft cabin flammability tests of improved fire-resistant materials, test series 2

    NASA Technical Reports Server (NTRS)

    Stuckey, R. N.; Bricker, R. W.; Kuminecz, J. F.; Supkis, D. E.

    1976-01-01

    Full-scale aircraft flammability tests in which the effectiveness of new fire-resistant materials was evaluated by comparing their burning characteristics with those of other fire-resistant aircraft materials were described. New-fire-resistant materials that are more economical and better suited for aircraft use than the previously tested fire-resistant materials were tested. The fuel ignition source for one test was JP-4; a smokeless fuel was used for the other test. Test objectives, methods, materials, and results are presented and discussed. The results indicate that, similar to the fire-resistant materials tested previously, the new materials decompose rather than ignite and do not support fire propagation. Furthermore, the new materials did not produce a flash fire.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, Alexander; Jernigan, Dann A.; Dodd, Amanda B.

    New aircraft are being designed with increasing quantities of composite materials used in their construction. Different from the more traditional metals, composites have a higher propensity to burn. This presents a challenge to transportation safety analyses, as the aircraft structure now represents an additional fuel source involved in the fire scenario. Most of the historical fire testing of composite materials is aime d at studying kinetics, flammability or yield strength under fire conditions. Most of this testing is small - scale. Heterogeneous reactions are often length - scale dependent, and this is thought to be particularly true for composites whichmore » exhibit signific ant microscopic dynamics that can affect macro - scale behavior. We have designed a series of tests to evaluate composite materials under various structural loading conditions with a consistent thermal condition. We have measured mass - loss , heat flux, and temperature throughout the experiments. Several types of panels have been tested, including simple composite panels, and sandwich panels. The main objective of the testing was to understand the importance of the structural loading on a composite to its b ehavior in response to fire - like conditions. During flaming combustion at early times, there are some features of the panel decomposition that are unique to the type of loading imposed on the panels. At load levels tested, fiber reaction rates at later t imes appear to be independent of the initial structural loading.« less

  13. Development of Fire Resistant/Heat Resistant Sewing Thread

    DTIC Science & Technology

    2016-03-01

    Final 3. DATES COVERED (From - To) October 2014 – June 2015 4. TITLE AND SUBTITLE DEVELOPMENT OF FIRE RESISTANT /HEAT RESISTANT SEWING THREAD 5a...core to sheath ratio of 70:30 will offer a high performance, low cost sewing thread with required fire resistant /heat resistant properties. 15...Properties ............................................................................... 18        1      DEVELOPMENT OF  FIRE   RESISTANT /HEAT

  14. Status of candidate materials for full-scale tests in the 737 fuselage

    NASA Technical Reports Server (NTRS)

    Supkis, D.

    1979-01-01

    The test program has the objectives to: (1) increase passenger evacuation time to a minimum of five minutes from commercial aircraft in case of a fire; (2) prevent an external fire from entering closed cabins for five minutes by using fire barrier materials in the exterior wall; (3) demonstrate that a closed cabin will not reach 400 F; and (4) prove that a fire near a cabin opening will not propagate through the cabin for a minimum of five minutes. The materials status is outlined for seat cushions, upholstery and associated seat materials, wall and ceiling panels, floor panels, carpet and carpet underlay, windows, cargo bay liners, insulation bagging, and thermal acoustical insulation.

  15. Industrial waste utilization in the panels production for high buildings facade and socle facing

    NASA Astrophysics Data System (ADS)

    Vitkalova, Irina; Torlova, Anastasiya; Pikalov, Evgeniy; Selivanov, Oleg

    2018-03-01

    The research presents comprehensive utilization of such industrial waste as galvanic sludge, broken window glass as functional additives for producing ceramics for facade and socle paneling in high-rise construction. The basic charge component is low-plasticity clay, which does not allow producing high-quality products if used without any functional additives. The application of the mentioned above components broadens the resource base, reduces production cost and the mass of the products in comparison with the currently used facing ceramics. The decrease of product mass helps to reduce the load on the basement and to use ceramic material in high-rise construction more effectively. Additional advantage of the developed composition is the reducing of production energy intensity due to comparatively low pressing pressure and firing temperature thus reducing the overall production cost. The research demonstrates the experimental results of determining density, compressive strength, water absorption, porosity and frost resistance of the produced ceramic material. These characteristics prove that the material can be applied for high buildings outdoor paneling. Additional research results prove ecologic safety of the produced ceramic material.

  16. Behaviour of Reinforced Concrete Columns of Various Cross-Sections Subjected to Fire

    NASA Astrophysics Data System (ADS)

    Balaji, Aneesha; Muhamed Luquman, K.; Nagarajan, Praveen; Madhavan Pillai, T. M.

    2016-09-01

    Fire resistance is one of the crucial design regulations which are now mandatory in most of the design codes. Therefore, a thorough knowledge of behaviour of structures exposed to fire is required in this aspect. Columns are the most vulnerable structural member to fire as it can be exposed to fire from all sides. However, the data available for fire resistant design for columns are limited. Hence the present work is focused on the effect of cross-sectional shape of column in fire resistance design. The various cross-sections considered are Square, Ell (L), Tee (T), and Plus (`+') shape. Also the effect of size and shape and distribution of steel reinforcement on fire resistance of columns is studied. As the procedure for determining fire resistance is not mentioned in Indian Standard code IS 456 (2000), the simplified method (500 °C isotherm method) recommended in EN 1992-1-2:2004 (E) (Eurocode 2) is adopted. The temperature profiles for various cross-sections are developed using finite element method and these profiles are used to predict fire resistance capability of compression members. The fire resistance based on both numerical and code based methods are evaluated and compared for various types of cross-section.

  17. 29 CFR 1926.155 - Definitions applicable to this subpart.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... part, fire resistance shall be determined by the Standard Methods of Fire Tests of Building... knowledgeable, trained, and skilled in the safe evacuation of employees during emergency situations and in assisting in fire fighting operations. (f) Fire resistance means so resistant to fire that, for specified...

  18. 29 CFR 1926.155 - Definitions applicable to this subpart.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... part, fire resistance shall be determined by the Standard Methods of Fire Tests of Building... knowledgeable, trained, and skilled in the safe evacuation of employees during emergency situations and in assisting in fire fighting operations. (f) Fire resistance means so resistant to fire that, for specified...

  19. 29 CFR 1926.155 - Definitions applicable to this subpart.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... part, fire resistance shall be determined by the Standard Methods of Fire Tests of Building... knowledgeable, trained, and skilled in the safe evacuation of employees during emergency situations and in assisting in fire fighting operations. (f) Fire resistance means so resistant to fire that, for specified...

  20. 29 CFR 1926.155 - Definitions applicable to this subpart.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... part, fire resistance shall be determined by the Standard Methods of Fire Tests of Building... knowledgeable, trained, and skilled in the safe evacuation of employees during emergency situations and in assisting in fire fighting operations. (f) Fire resistance means so resistant to fire that, for specified...

  1. 29 CFR 1926.155 - Definitions applicable to this subpart.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... part, fire resistance shall be determined by the Standard Methods of Fire Tests of Building... knowledgeable, trained, and skilled in the safe evacuation of employees during emergency situations and in assisting in fire fighting operations. (f) Fire resistance means so resistant to fire that, for specified...

  2. 76 FR 71831 - Defense Federal Acquisition Regulation Supplement: Fire-Resistant Fiber for Production of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-18

    ..., suppliers, or distributors of fire-resistant fibers, yarns, fabrics, or military uniforms) submitted.... The law does not restrict DoD's selection and use of fabrics containing fire-resistant rayon fiber... from selecting fabrics that include fire- resistant rayon fibers. Response: These responses have...

  3. Forest-fire model with natural fire resistance.

    PubMed

    Yoder, Mark R; Turcotte, Donald L; Rundle, John B

    2011-04-01

    Observations suggest that contemporary wildfire suppression practices in the United States have contributed to conditions that facilitate large, destructive fires. We introduce a forest-fire model with natural fire resistance that supports this theory. Fire resistance is defined with respect to the size and shape of clusters; the model yields power-law frequency-size distributions of model fires that are consistent with field observations in the United States, Canada, and Australia.

  4. Wildland fire management futures: insights from a foresight panel

    Treesearch

    Robert L. Olson; David N. Bengston; Leif A. DeVaney; Trevor A.C. Thompson

    2015-01-01

    Wildland fire management faces unprecedented challenges in the 21st century: the increasingly apparent effects of climate change, more people and structures in the wildland-urban interface, growing costs associated with wildfire management, and the rise of high-impact fires, to name a few. Given these significant and growing challenges, conventional fire management...

  5. Propulsion and Energetics Panel Working Group 11 on Aircraft Fire Safety. Volume 2. Main Report

    DTIC Science & Technology

    1979-11-01

    which make burning metal particles a potent igni- tion source and extinguishment of bulk metal fires a difficult task. In the latter case, the difficulty...aircraft to fires induced by uncon- tained engine failures and internal engine metal fires . With respect to the uncontained engine failure current engine

  6. Network-Based Real-time Integrated Fire Detection and Alarm (FDA) System with Building Automation

    NASA Astrophysics Data System (ADS)

    Anwar, F.; Boby, R. I.; Rashid, M. M.; Alam, M. M.; Shaikh, Z.

    2017-11-01

    Fire alarm systems have become increasingly an important lifesaving technology in many aspects, such as applications to detect, monitor and control any fire hazard. A large sum of money is being spent annually to install and maintain the fire alarm systems in buildings to protect property and lives from the unexpected spread of fire. Several methods are already developed and it is improving on a daily basis to reduce the cost as well as increase quality. An integrated Fire Detection and Alarm (FDA) systems with building automation was studied, to reduce cost and improve their reliability by preventing false alarm. This work proposes an improved framework for FDA system to ensure a robust intelligent network of FDA control panels in real-time. A shortest path algorithmic was chosen for series of buildings connected by fiber optic network. The framework shares information and communicates with each fire alarm panels connected in peer to peer configuration and declare the network state using network address declaration from any building connected in network. The fiber-optic connection was proposed to reduce signal noises, thus increasing large area coverage, real-time communication and long-term safety. Based on this proposed method an experimental setup was designed and a prototype system was developed to validate the performance in practice. Also, the distributed network system was proposed to connect with an optional remote monitoring terminal panel to validate proposed network performance and ensure fire survivability where the information is sequentially transmitted. The proposed FDA system is different from traditional fire alarm and detection system in terms of topology as it manages group of buildings in an optimal and efficient manner.Introduction

  7. Effects of fire retardants on physical, mechanical, and fire properties of flat-pressed WPCs

    Treesearch

    Nadir Ayrilmis; Jan T. Benthien; Heiko Thoemen; Robert H. White

    2012-01-01

    Physical, mechanical, and fire properties of the flat-pressed wood plastic composites (WPCs) incorporated with various fire retardants (10% by weight) at different levels of wood flour (WF) content, 40, 50, or 60 wt%, were investigated. The WPC panels were made from dry-blended WF, polypropylene (PP), and fire retardant (FR) powders with maleic anhydride-grafted PP (2...

  8. Fire-retardant-treated strandboard : properties and fire performance

    Treesearch

    Jerrold Winandy; Qingwen Wang; Robert H. White

    2008-01-01

    This study evaluated a series of single-layer, randomly oriented strandboard panels made with one resin type, a single resin loading level, and four fire-retardant-treatment levels. The fire retardant (FR) evaluated was a pH-buffered combination of boric acid and organic phosphate. Siberian larch strands were separated into five batches. One batch of strands served as...

  9. Public acceptance of wildland fire and fuel management: Panel responses in seven locations

    Treesearch

    Eric Toman; Bruce Shindler; Sarah McCaffrey; James Bennett

    2014-01-01

    Wildland fire affects both public and private resources throughout the United States. A century of fire suppression has contributed to changing ecological conditions and accumulated fuel loads. Managers have used a variety of approaches to address these conditions and reduce the likelihood of wildland fires that may result in adverse ecological impacts and threaten...

  10. Multicenter Evaluation of the ePlex Respiratory Pathogen Panel for the Detection of Viral and Bacterial Respiratory Tract Pathogens in Nasopharyngeal Swabs

    PubMed Central

    England, Matthew R.; Jurcic Smith, Kristen L.; He, Taojun; Wijetunge, Dona Saumya; Chamberland, Robin R.; Menegus, Marilyn; Swierkosz, Ella M.; Jerris, Robert C.; Greene, Wallace

    2017-01-01

    ABSTRACT The performance of the new ePlex Respiratory Pathogen (RP) panel (GenMark Diagnostics) for the simultaneous detection of 19 viruses (influenza A virus; influenza A H1 virus; influenza A 2009 H1 virus; influenza A H3 virus; influenza B virus; adenovirus; coronaviruses [HKU1, OC43, NL63, and 229E]; human rhinovirus/enterovirus; human metapneumovirus; parainfluenza viruses 1, 2, 3, and 4; and respiratory syncytial virus [RSV] [RSV subtype A and RSV subtype B]) and 2 bacteria (Mycoplasma pneumoniae and Chlamydia pneumoniae) was evaluated. Prospectively and retrospectively collected nasopharyngeal swab (NPS) specimens (n = 2,908) were evaluated by using the ePlex RP panel, with the bioMérieux/BioFire FilmArray Respiratory Panel (BioFire RP) as the comparator method. Discordance analysis was performed by using target-specific PCRs and bidirectional sequencing. The reproducibility of the assay was evaluated by using reproducibility panels comprised of 6 pathogens. The overall agreement between the ePlex RP and BioFire RP results was >95% for all targets. Positive percent agreement with the BioFire RP result for viruses ranged from 85.1% (95% confidence interval [CI], 80.2% to 88.9%) to 95.1% (95% CI, 89.0% to 97.9%), while negative percent agreement values ranged from 99.5% (95% CI, 99.1% to 99.7%) to 99.8% (95% CI, 99.5% to 99.9%). Additional testing of discordant targets (12%; 349/2,908) confirmed the results of ePlex RP for 38% (131/349) of samples tested. Reproducibility was 100% for all targets tested, with the exception of adenovirus, for which reproducibilities were 91.6% at low virus concentrations and 100% at moderate virus concentrations. The ePlex RP panel offers a new, rapid, and sensitive “sample-to-answer” multiplex panel for the detection of the most common viral and bacterial respiratory pathogens. PMID:29212701

  11. Development of a Midscale Test for Flame Resistant Protection

    DTIC Science & Technology

    2016-08-01

    Evaluation of Flame Resistant Clothing for Protection against Fire Simulations Using an Instrumented Manikin, which provides both radiant and convective heat...TEST METHODS FIRE RESISTANT MATERIALS TORCHES SIMULATION TEST EQUIPMENT FLAME RESISTANT CLOTHING PERFORMANCE(ENGINEERING... fabric during a fire , and even after the fire has been extinguished. The best known full scale transmitted heat flux test is the "ASTM F1930

  12. Study of materials performance model for aircraft interiors

    NASA Technical Reports Server (NTRS)

    Leary, K.; Skratt, J.

    1980-01-01

    A demonstration version of an aircraft interior materials computer data library was developed and contains information on selected materials applicable to aircraft seats and wall panels, including materials for the following: panel face sheets, bond plies, honeycomb, foam, decorative film systems, seat cushions, adhesives, cushion reinforcements, fire blocking layers, slipcovers, decorative fabrics and thermoplastic parts. The information obtained for each material pertains to the material's performance in a fire scenario, selected material properties and several measures of processability.

  13. 46 CFR 27.203 - What are the requirements for fire detection on towing vessels?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...— (a) Each detector, each control panel, and each fire alarm are approved under 46 CFR subpart 161.002...; (c) The system is arranged and installed so a fire in the engine room automatically sets off alarms... light; (2) Both an audible alarm to notify crew at the operating station of fire and visible alarms to...

  14. 46 CFR 27.203 - What are the requirements for fire detection on towing vessels?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...— (a) Each detector, each control panel, and each fire alarm are approved under 46 CFR subpart 161.002...; (c) The system is arranged and installed so a fire in the engine room automatically sets off alarms... light; (2) Both an audible alarm to notify crew at the operating station of fire and visible alarms to...

  15. 46 CFR 27.203 - What are the requirements for fire detection on towing vessels?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...— (a) Each detector, each control panel, and each fire alarm are approved under 46 CFR subpart 161.002...; (c) The system is arranged and installed so a fire in the engine room automatically sets off alarms... light; (2) Both an audible alarm to notify crew at the operating station of fire and visible alarms to...

  16. 46 CFR 27.203 - What are the requirements for fire detection on towing vessels?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...— (a) Each detector, each control panel, and each fire alarm are approved under 46 CFR subpart 161.002...; (c) The system is arranged and installed so a fire in the engine room automatically sets off alarms... light; (2) Both an audible alarm to notify crew at the operating station of fire and visible alarms to...

  17. Validation of a Polyimide Foam Model for Use in Transmission Loss Applications

    NASA Technical Reports Server (NTRS)

    Hong, Kwanwoo; Bolton, J. Stuart; Cano, Roberto J.; Weiser, Erik S.; Jensen, Brian J.; Silcox, Rich; Howerton, Brian M.; Maxon, John; Wang, Tongan; Lorenzi, Tyler

    2010-01-01

    The work described in this paper was focused on the use of a new polyimide foam in a double wall sound transmission loss application. Recall that polyimide foams are functionally attractive, compared to polyurethane foams, for example, owing to their fire resistance. The foam considered here was found to have a flow resistivity that was too high for conventional acoustical applications, and as a result, it was processed by partial crushing to lower the flow resistivity into an acceptable range. Procedures for measuring the flow resistivity and Young s modulus of the material have been described, as was an inverse characterization procedure for estimating the remaining Biot parameters based on standing wave tube measurements of transmission loss and absorption coefficient. The inverse characterization was performed using a finite element model implementation of the Biot poro-elastic material theory. Those parameters were then used to predict the sound transmission loss of a double panel system lined with polyimide foam, and the predictions were compared with full-scale transmission loss measurements. The agreement between the two was reasonable, especially in the high and low frequency limits; however, it was found that the SEA model resulted in an under-prediction of the transmission loss in the mid-frequency range. Nonetheless, it was concluded that the performance of polyimide foam could be predicted using conventional poro-elastic material models and that polyimide foam may offer an attractive alternative to other double wall linings in certain situations: e.g., when fire resistance is a key issue. Future work will concentrate on reducing the density of the foam to values similar to those used in current aircraft sidewall treatments, and developing procedures to improve the performance of the foam in transmission loss applications.

  18. Evaluation of Materials and Concepts for Aircraft Fire Protection

    NASA Technical Reports Server (NTRS)

    Anderson, R. A.; Price, J. O.; Mcclure, A. H.; Tustin, E. A.

    1976-01-01

    Woven fiberglass fluted-core simulated aircraft interior panels were flame tested and structurally evaluated against the Boeing 747 present baseline interior panels. The NASA-defined panels, though inferior on a strength-to-weight basis, showed better structural integrity after flame testing, due to the woven fiberglass structure.

  19. Fire and grazing influence site resistance to Bromus tectorum through their effects on shrub, bunchgrass and biocrust communities in the Great Basin (USA)

    USGS Publications Warehouse

    Condon, Lea A.; Pyke, David A.

    2018-01-01

    Shrubs, bunchgrasses and biological soil crusts (biocrusts) are believed to contribute to site resistance to plant invasions in the presence of cattle grazing. Although fire is a concomitant disturbance with grazing, little is known regarding their combined impacts on invasion resistance. We are the first to date to test the idea that biotic communities mediate the effects of disturbance on site resistance. We assessed cover of Bromus tectorum, shrubs, native bunchgrasses, lichens and mosses in 99 burned and unburned plots located on similar soils where fires occurred between 12 and 23 years before sampling. Structural equation modeling was used to test hypothesized relationships between environmental and disturbance characteristics, the biotic community and resistance to B. tectorum cover. Characteristics of fire and grazing did not directly relate to cover of B. tectorum. Relationships were mediated through shrub, bunchgrass and biocrust communities. Increased site resistance following fire was associated with higher bunchgrass cover and recovery of bunchgrasses and mosses with time since fire. Evidence of grazing was more pronounced on burned sites and was positively correlated with the cover of B. tectorum, indicating an interaction between fire and grazing that decreases site resistance. Lichen cover showed a weak, negative relationship with cover of B. tectorum. Fire reduced near-term site resistance to B. tectorum on actively grazed rangelands. Independent of fire, grazing impacts resulted in reduced site resistance to B. tectorum, suggesting that grazing management that enhances plant and biocrust communities will also enhance site resistance.

  20. Prototypical Recombinant Multi-Protease-Inhibitor-Resistant Infectious Molecular Clones of Human Immunodeficiency Virus Type 1

    PubMed Central

    Varghese, Vici; Mitsuya, Yumi; Fessel, W. Jeffrey; Liu, Tommy F.; Melikian, George L.; Katzenstein, David A.; Schiffer, Celia A.; Holmes, Susan P.

    2013-01-01

    The many genetic manifestations of HIV-1 protease inhibitor (PI) resistance present challenges to research into the mechanisms of PI resistance and the assessment of new PIs. To address these challenges, we created a panel of recombinant multi-PI-resistant infectious molecular clones designed to represent the spectrum of clinically relevant multi-PI-resistant viruses. To assess the representativeness of this panel, we examined the sequences of the panel's viruses in the context of a correlation network of PI resistance amino acid substitutions in sequences from more than 10,000 patients. The panel of recombinant infectious molecular clones comprised 29 of 41 study-defined PI resistance amino acid substitutions and 23 of the 27 tightest amino acid substitution clusters. Based on their phenotypic properties, the clones were classified into four groups with increasing cross-resistance to the PIs most commonly used for salvage therapy: lopinavir (LPV), tipranavir (TPV), and darunavir (DRV). The panel of recombinant infectious molecular clones has been made available without restriction through the NIH AIDS Research and Reference Reagent Program. The public availability of the panel makes it possible to compare the inhibitory activities of different PIs with one another. The diversity of the panel and the high-level PI resistance of its clones suggest that investigational PIs active against the clones in this panel will retain antiviral activity against most if not all clinically relevant PI-resistant viruses. PMID:23796938

  1. Fire resistance of structural composite lumber products

    Treesearch

    Robert H. White

    2006-01-01

    Use of structural composite lumber products is increasing. In applications requiring a fire resistance rating, calculation procedures are used to obtain the fire resistance rating of exposed structural wood products. A critical factor in the calculation procedures is char rate for ASTM E 119 fire exposure. In this study, we tested 14 structural composite lumber...

  2. Efficacy Testing of Pesticides used for Invertebrate Pests and Fire Ants

    EPA Pesticide Factsheets

    Event page for the upcoming Federal Insecticide, Fungicide, and Rodenticide Act (FIFRA) Scientific Advisory Panel (SAP) meeting on Efficacy Testing of Pesticides used for Invertebrate Pests and Fire Ants

  3. Aerogel Hybrid Composite Materials: Designs and Testing for Multifunctional Applications

    NASA Technical Reports Server (NTRS)

    Williams, Martha K.; Fesmire, James E.

    2016-01-01

    This webinar will introduce the broad spectrum of aerogel composites and their diverse performance properties such as reduced heat transfer to energy storage, and expands specifically on the aerogel/fiber laminate systems and testing methodologies. The multi-functional laminate composite system, AeroFiber, and its construction is designed by varying the type of fiber (e.g. polyester, carbon, Kevlar®, Spectra® or Innegral(TradeMark) and combinations thereof), the aerogel panel type and thickness, and overall layup configuration. The combination and design of materials may be customized and tailored to achieve a range of desired properties in the resulting laminate system. Multi-functional properties include structural strength, impact resistance, reduction in heat transfer, increased fire resistance, mechanical energy absorption, and acoustic energy dampening. Applications include aerospace, aircraft, automotive, boating, building and construction, lightweight portable structures, liquefied natural gas, cryogenics, transportation and energy, sporting equipment, and military protective gear industries.

  4. Thermally insulating and fire-retardant lightweight anisotropic foams based on nanocellulose and graphene oxide.

    PubMed

    Wicklein, Bernd; Kocjan, Andraž; Salazar-Alvarez, German; Carosio, Federico; Camino, Giovanni; Antonietti, Markus; Bergström, Lennart

    2015-03-01

    High-performance thermally insulating materials from renewable resources are needed to improve the energy efficiency of buildings. Traditional fossil-fuel-derived insulation materials such as expanded polystyrene and polyurethane have thermal conductivities that are too high for retrofitting or for building new, surface-efficient passive houses. Tailored materials such as aerogels and vacuum insulating panels are fragile and susceptible to perforation. Here, we show that freeze-casting suspensions of cellulose nanofibres, graphene oxide and sepiolite nanorods produces super-insulating, fire-retardant and strong anisotropic foams that perform better than traditional polymer-based insulating materials. The foams are ultralight, show excellent combustion resistance and exhibit a thermal conductivity of 15 mW m(-1) K(-1), which is about half that of expanded polystyrene. At 30 °C and 85% relative humidity, the foams retained more than half of their initial strength. Our results show that nanoscale engineering is a promising strategy for producing foams with excellent properties using cellulose and other renewable nanosized fibrous materials.

  5. Fire resistance of wood members with directly applied protection

    Treesearch

    Robert H. White

    2009-01-01

    Fire-resistive wood construction is achieved either by having the structural elements be part of fire-rated assemblies or by using elements of sufficient size that the elements themselves have the required fire-resistance ratings. For exposed structural wood elements, the ratings in the United States are calculated using either the T.T. Lie method or the National...

  6. FilmArray® Gastrointestinal (GI) Panel for Viral Acute Gastroenteritis Detection in Pediatric Patients

    PubMed Central

    Kanwar, Neena; Jackson, Jami; Duffy, Susan; Chapin, Kimberle; Cohen, Daniel; Leber, Amy; Daly, Judy a; Pavia, Andrew; Larsen, Chari; Baca, Tanya; Bender, Jeffery; Bard, Jennifer Dien; Festekjian, Ara; Holmberg, Kristen; Bourzac, Kevin; Selvarangan, Rangaraj

    2017-01-01

    Abstract Background Acute viral gastroenteritis is one of the leading causes of diarrheal diseases. The FilmArray GI Panel is a PCR based assay that detects 22 different enteric pathogens including five viruses (Adenovirus F 40/41, Astrovirus, Norovirus GI/GII, Rotavirus A, and Sapovirus (I, II, IV, and V)) in an hour. The epidemiology and management of acute viral gastroenteritis is described. Methods Children with acute gastroenteritis were prospectively enrolled at emergency departments of five geographically different pediatric facilities during 2015–2016. Stool specimens were collected and tested by the FilmArray GI Panel. Results A total of 1157 subjects were enrolled in the study. Stool specimens from 961 subjects were collected. Subjects with viral, bacterial, and parasitic etiology as identified by the FilmArray GI Panel were 429 (44.6%), 392 (40.8%), and 41 (4.3%), respectively. Viral AGE was common in winter months from October through March (274/429; 63.9%); norovirus was the leading viral agent (205/429; 47.8%) and was more commonly detected in winter months (147/205; 71.7%). Other viruses detected include Adenovirus F 40/41, Astrovirus, Rotavirus, and Sapovirus in 94 (9.8%), 49 (5.1%), 28 (2.9%), and 97 (10.1%) specimens, respectively. Co-infections with multiple pathogens was found in 244 (25.4%) of all specimens tested. Only 39/961 subjects received a viral standard of care (SOC) test result. The FilmArray GI panel detected viruses in higher percentage of stool specimens when SOC was not requested 45% (415/922) vs. requested 36% (14/39) [P = 0.32]. Viral infections were the highest among 148 hospitalizations: virus (26.4%), bacteria (22.9%), bacteria and virus (16.9%), and parasite (0.6%) and norovirus was the leading viral etiology associated with hospitalizations (n = 27; 69.2%). AGE due to viral (24.6%) or bacterial (27.6%) causes had similar repeat visits to hospital [P = 0.45]. Conclusion Viruses are leading cause of AGE resulting in ED visits; norovirus is the leading viral agent. Viral AGE leads to significant hospitalizations and repeat hospital visits. Implementation of comprehensive test like the FilmArray GI panel may aid in appropriate management of children with AGE. Disclosures S. Duffy, BioFire Diagnostics: Investigator, Research grant; K. Chapin, BioFire Diagnostics: Investigator, Research grant; A. Leber, BioFIre Diagnostics: Research Contractor and Scientific Advisor, Research support, Speaker honorarium and Travel expenses; A. Pavia, BioFire Diagnostics: Grant Investigator, Research grant; J. Dien Bard, BioFire: Consultant and Investigator, Research grant and Speaker honorarium; 
 K. Holmberg, BioFire Diagnostics: Employee, Salary; K. Bourzac, BioFire Diagnostics: Employee, Salary; R. Selvarangan, BioFire Diagnostics: Board Member and Investigator, Consulting fee and Research grant; Luminex Diagnostics: Investigator, Research grant

  7. Conference on Fire Resistant Materials: A compilation of presentations and papers

    NASA Technical Reports Server (NTRS)

    Kourtides, D. A. (Editor); Johnson, G. A. (Editor)

    1979-01-01

    The proceedings of the NASA IRE Resistant Materials Engineering (FIREMEN) Program held at Boeing Commercial Airplane Company, Seattle, Washington, on March 1-2, 1979 are reported. The conference was to discuss the results of research by the National Aeronautics and Space Administration in the field of aircraft fire safety and fire-resistant materials. The program topics include the following: (1) large-scale testing; (2) fire toxicology; (3) polymeric materials; and (4) fire modeling.

  8. Conference on Fire Resistant Materials (FIREMEN): A compilation of presentations and papers

    NASA Technical Reports Server (NTRS)

    Kourtides, D. A. (Editor)

    1978-01-01

    The proceedings of the NASA Fire Resistant Materials Engineering (FIREMEN) Program held at Ames Research Center on April, 13, 14, 1978 are reported. The purpose of the conference was to discuss the results of NASA in the field of aircraft fire safety and fire resistant materials. The program components include the following: (1) large-scale testing; (2) fire toxicology; (3) polymeric materials; and (4) bibliography related and/or generated from the program.

  9. Fire Resistant, Moisture Barrier Membrane

    NASA Technical Reports Server (NTRS)

    St.Clair, Terry L. (Inventor)

    2000-01-01

    A waterproof and breathable, fire-resistant laminate is provided for use in tents, garments, shoes, and covers, especially in industrial, military and emergency situations. The laminate permits water vapor evaporation while simultaneously preventing liquid water penetration. Further, the laminate is fire-resistant and significantly reduces the danger of toxic compound production when exposed to flame or other high heat source. The laminate may be applied to a variety of substrates and is comprised of a silicone rubber and plurality of fire-resistant, inherently thermally-stable polyimide particles.

  10. Fire Resistant, Moisture Barrier Membrane

    NASA Technical Reports Server (NTRS)

    St.Clair, Terry L. (Inventor)

    1998-01-01

    A waterproof and breathable, fire-resistant laminate is provided for use in tents, garments, shoes, and covers, especially in industrial, military and emergency situations. The laminate permits water vapor evaporation while simultaneously preventing liquid water penetration. Further, the laminate is fire-resistant and significantly reduces the danger of toxic compound production when exposed to flame or other high heat source. The laminate may be applied to a variety of substrates and is comprised of a silicone rubber and plurality of fire-resistant, inherently thermally-stable polyimide particles.

  11. Putative resistance gene markers associated with quantitative trait loci for fire blight resistance in Malus 'Robusta 5' accessions

    USDA-ARS?s Scientific Manuscript database

    Breeding of fire blight resistant scions and rootstocks is a goal of several international apple breeding programs, as options are limited for management of this destructive disease caused by the bacterial pathogen Erwinia amylovora. A broad, large effect QTL for fire blight resistance has been pre...

  12. Full-scale aircraft cabin flammability tests of improved fire-resistant materials

    NASA Technical Reports Server (NTRS)

    Stuckey, R. N.; Surpkis, D. E.; Price, L. J.

    1974-01-01

    Full-scale aircraft cabin flammability tests to evaluate the effectiveness of new fire-resistant materials by comparing their burning characteristics with those of older aircraft materials are described. Three tests were conducted and are detailed. Test 1, using pre-1968 materials, was run to correlate the procedures and to compare the results with previous tests by other organizations. Test 2 included newer, improved fire-resistant materials. Test 3 was essentially a duplicate of test 2, but a smokeless fuel was used. Test objectives, methods, materials, and results are presented and discussed. Results indicate that the pre-1968 materials ignited easily, allowed the fire to spread, produced large amounts of smoke and toxic combustion products, and resulted in a flash fire and major fire damage. The newer fire-resistant materials did not allow the fire to spread. Furthermore, they produced less, lower concentrations of toxic combustion products, and lower temperatures. The newer materials did not produce a flash fire.

  13. Fire resistivity and toxicity studies of candidate aircraft passenger seat materials

    NASA Technical Reports Server (NTRS)

    Fewell, L. L.; Trabold, E. L.; Spieth, H.

    1978-01-01

    Fire resistivity studies were conducted on a wide range of candidate nonmetallic materials being considered for the construction of improved fire resistant aircraft passenger seats. These materials were evaluated on the basis of FAA airworthiness burn and smoke generation tests, colorfastness, limiting oxygen index, and animal toxicity tests. Physical, mechanical, and aesthetic properties were also assessed. Candidate seat materials that have significantly improved thermal response to various thermal loads corresponding to reasonable fire threats as they relate to in-flight fire situations, are identified.

  14. Advanced fire-resistant forms of activated carbon and methods of adsorbing and separating gases using same

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xiong, Yongliang; Wang, Yifeng

    A method of removing a target gas from a gas stream is disclosed. The method uses advanced, fire-resistant activated carbon compositions having vastly improved fire resistance. Methods for synthesizing the compositions are also provided. The advanced compositions have high gas adsorption capacities and rapid adsorption kinetics (comparable to commercially-available activated carbon), without having any intrinsic fire hazard.

  15. Elucidating the effects of solar panel waste glass substitution on the physical and mechanical characteristics of clay bricks.

    PubMed

    Lin, Kae-Long; Huang, Long-Sheng; Shie, Je-Lueng; Cheng, Ching-Jung; Lee, Ching-Hwa; Chang, Tien-Chin

    2013-01-01

    This study deals with the effect of solar panel waste glass on fired clay bricks. Brick samples were heated to temperatures which varied from 700-1000 degrees C for 6 h, with a heating rate of 10 degrees C min(-1). The material properties of the resultant material were then determined, including speciation variation, loss on ignition, shrinkage, bulk density, 24-h absorption rate, compressive strength and salt crystallization. The results indicate that increasing the amount of solar panel waste glass resulted in a decrease in the water absorption rate and an increase in the compressive strength of the solar panel waste glass bricks. The 24-h absorption rate and compressive strength of the solar panel waste glass brick made from samples containing 30% solar panel waste glass sintered at 1000 degrees C all met the Chinese National Standard (CNS) building requirements for first-class brick (compressive strengths and water absorption of the bricks were 300 kg cm(-2) and 10% of the brick, respectively). The addition of solar panel waste glass to the mixture reduced the degree of firing shrinkage. The salt crystallization test and wet-dry tests showed that the addition of solar panel waste glass had highly beneficial effects in that it increased the durability of the bricks. This indicates that solar panel waste glass is indeed suitable for the partial replacement of clay in bricks.

  16. Industrial application of low voltage bidirectional automatic release of reserve

    NASA Astrophysics Data System (ADS)

    Popa, G. N.; Diniş, C. M.; Iagăr, A.; Deaconu, S. I.; Popa, I.

    2018-01-01

    The paper presents an analysis on low voltage industrial electrical installation controlled by bidirectional automatic release of reserve. Industrial electrical installation is for removing smoke in case of fire from a textile company. The main parts of the installation of removing smoke in case of fire are: general electrical panel; reserve electrical panel; three-phase induction motors for driven fans; electrical actuators for inlet and outlet valves; clean air inlet pipe, respectively, the outlet pipe for smoke. The operation and checking of bidirectional automatic release of reserve are present in the paper.

  17. 30 CFR 77.1913 - Fire-resistant wood.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Fire-resistant wood. 77.1913 Section 77.1913 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH... Shaft Sinking § 77.1913 Fire-resistant wood. Except for crossties, timbers, and other wood products...

  18. 30 CFR 77.1913 - Fire-resistant wood.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Fire-resistant wood. 77.1913 Section 77.1913 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH... Shaft Sinking § 77.1913 Fire-resistant wood. Except for crossties, timbers, and other wood products...

  19. 30 CFR 77.1913 - Fire-resistant wood.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Fire-resistant wood. 77.1913 Section 77.1913 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH... Shaft Sinking § 77.1913 Fire-resistant wood. Except for crossties, timbers, and other wood products...

  20. 46 CFR 72.05-55 - Furniture and furnishings.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... shall be of approved fire resistant fabrics. (4) All rugs and carpets shall be of wool or other material... subpart, rooms containing “fire resistant furnishings” will be considered to be those in which: (1) All... fire resistant furnishings. In addition, all upholstery and padding of chairs, sofas, etc., in these...

  1. 30 CFR 77.1913 - Fire-resistant wood.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Fire-resistant wood. 77.1913 Section 77.1913 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH... Shaft Sinking § 77.1913 Fire-resistant wood. Except for crossties, timbers, and other wood products...

  2. 30 CFR 77.1913 - Fire-resistant wood.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fire-resistant wood. 77.1913 Section 77.1913 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH... Shaft Sinking § 77.1913 Fire-resistant wood. Except for crossties, timbers, and other wood products...

  3. Commandant’s International Technical Series. Volume 8. Fire Aboard the M.S. SCANDINAVIAN SEA on March 9, 1984. Technical Assessment

    DTIC Science & Technology

    1985-01-01

    Bulkheads - 5/8" asbestos cement panels Ceilings - 3/8" asbestos cement panels Structural insulation - mineral wool Ducting and Hull Insulation-fibrous...glass/ mineral wool D6ryks - steel Linings - 3/4" and 5/8" asbestos cement panels Interior finish - melamine plastic laminate Furnishings - wood and

  4. Cone calorimeter testing of foam core sandwich panels treated with intumescent paper underneath the veneer (FRV)

    Treesearch

    Mark A. Dietenberger; Ali Shalbafan; Johannes Welling

    2017-01-01

    Surfaces of novel foam core sandwich panels were adhered with intumescent fire‐retardant paper underneath the veneers (FRV) to improve their flammability properties. The panels were evaluated by means of cone calorimeter test (ASTM E 1354). Variables tested were different surface layer treatments, adhesives used for veneering, surface layer thicknesses, and processing...

  5. Studies of the physical aspects of intumescence using advance diagnostics methods

    NASA Astrophysics Data System (ADS)

    Saeed, Hussain; Huang, Hua Wei; Zhang, Yang

    2014-04-01

    The use of intumescent paints as an active fire protection method has gained immense interest in recent years. A significant aspect of research has focused on studying the chemical aspects of the system to improve performance. The dynamics and physical aspects of intumescence in real time fire conditions are still unclear. The present research uses an experimental approach where diagnostics techniques such as thermal imaging camera was used to study intumescent characteristics that have been not been reported in great detail. T-panels are a substitute to the most commonly used part in construction, the I-beam. Studies were conducted using a cone calorimeter that provided a uniform heat flux through radiation on steel T-panel samples. The complex nature of char movement was recorded and a novel algorithm was used to track the growing char laye07r. The samples are designed to cater to different fire conditions. Therefore, the degree of intumescence was observed to be very different in the samples. The samples designed for low temperature cellulosic fires focus on high degree of intumesce. Whereas, mechanical strength is the focus for samples used in high temperature turbulent hydrocarbon fire conditions. The variation in the internal structure of the sample is presented. Furthermore, the phenomenon is phase shift is discussed. The phase shift is an essential part of the process of intumescence when the majority of intumescence occurs. It was observed to be different in all the samples. The movement of the samples is a property of great interest. This is because if any part of the substrate is exposed then the formulation does not meet strict commercialisation criterion. The movement was diagonal in nature as compared to flat panels where it is perpendicular. This is due tot the heating pattern of the plate that results in the web part of the panel to influence the growth of char on the flange part of the panel. A special case of char cracking is also highlighted and using image processing algorithm on the thermal imaging data. A quantitative method of analsysis is presented to an otherwise commonly qualitative nature of experimental study in this field.

  6. Properties of flat-pressed wood plastic composites containing fire retardants

    Treesearch

    Nadir Ayrilmis; Jan. T. Benthien; Heiko Thoemen; Robert H. White

    2011-01-01

    This study investigated physical, mechanical, and fire properties of the flat-pressed wood plastic composites (WPCs) incorporated with various fire retardants (FRs) [5 or 15% by weight (wt)] at 50 wt % of the wood flour (WF). The WPC panels were made from dry-blended WF, polypropylene (PP) with maleic anhydride grafted PP (2 wt %), and FR powder formulations using a...

  7. Resistance to invasion and resilience to fire in desert shrublands of North America

    USGS Publications Warehouse

    Brooks, Matthew L.; Chambers, Jeanne C.

    2011-01-01

    Settlement by Anglo-Americans in the desert shrublands of North America resulted in the introduction and subsequent invasion of multiple nonnative grass species. These invasions have altered presettlement fire regimes, resulted in conversion of native perennial shrublands to nonnative annual grasslands, and placed many native desert species at risk. Effective management of these ecosystems requires an understanding of their ecological resistance to invasion and resilience to fire. Resistance and resilience differ among the cold and hot desert shrublands of the Great Basin, Mojave, Sonoran, and Chihuahuan deserts in North America. These differences are largely determined by spatial and temporal patterns of productivity but also are affected by ecological memory, severity and frequency of disturbance, and feedbacks among invasive species and disturbance regimes. Strategies for preventing or managing invasive plant/fire regimes cycles in desert shrublands include: 1) conducting periodic resource assessments to evaluate the probability of establishment of an altered fire regime; 2) developing an understanding of ecological thresholds associate within invasion resistance and fire resilience that characterize transitions from desirable to undesirable fire regimes; and 3) prioritizing management activities based on resistance of areas to invasion and resilience to fire.

  8. 49 CFR 178.358 - Specification 21PF fire and shock resistant, phenolic-foam insulated, metal overpack.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Specification 21PF fire and shock resistant, phenolic-foam insulated, metal overpack. 178.358 Section 178.358 Transportation Other Regulations Relating...) Materials § 178.358 Specification 21PF fire and shock resistant, phenolic-foam insulated, metal overpack. ...

  9. 49 CFR 178.358 - Specification 21PF fire and shock resistant, phenolic-foam insulated, metal overpack.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Specification 21PF fire and shock resistant, phenolic-foam insulated, metal overpack. 178.358 Section 178.358 Transportation Other Regulations Relating... Class 7 (Radioactive) Materials § 178.358 Specification 21PF fire and shock resistant, phenolic-foam...

  10. Report of the Army Scientific Advisory Panel Ad Hoc Group on Fire Suppression

    DTIC Science & Technology

    1975-07-01

    initially should be provided a nucleus of a seven- person technical staff composed of one 0-6 combat arme officer as Director, two senior behavioral ...If the suppressee perceives the fire as being reactive to his own behavior then the personal danger factor will be reinforced,1 Fire...that is not periodic hut also not reactive to his behavior may be like periodic fire in its personal threat except more difficult to

  11. Validation and Verification (V and V) Testing on Midscale Flame Resistant (FR) Test Method

    DTIC Science & Technology

    2016-12-16

    Method for Evaluation of Flame Resistant Clothing for Protection against Fire Simulations Using an Instrumented Manikin. Validation and...complement (not replace) the capabilities of the ASTM F1930 Standard Test Method for Evaluation of Flame Resistant Clothing for Protection against Fire ...Engineering Center (NSRDEC) to complement the ASTM F1930 Standard Test Method for Evaluation of Flame Resistant Clothing for Protection against Fire

  12. Effect of Spacecraft Environmental Variables on the Flammability of Fire Resistant Fabrics

    NASA Astrophysics Data System (ADS)

    Osorio, A. F.; Fernandez-Pello, C.; Takahashi, S.; Rodriguez, J.; Urban, D. L.; Ruff, G.

    2012-01-01

    Fire resistant fabrics are used for firefighter, racecar drivers as well as astronaut suits. However, their fire resistant characteristics depend on the environment conditions and require study. Particularly important is the response of these fabrics to elevated oxygen concentration environments and radiant heat from a source such as an adjacent fire. In this work, experiments using two fire resistant fabrics were conducted to study the effect of oxygen concentration, external radiant flux and oxidizer flow velocity in concurrent flame spread. Results show that for a given fabric the minimum oxygen concentration for flame spread depends strongly on the magnitude of the external radiant flux. At increased oxygen concentrations the external radiant flux required for flame spread decreases. Oxidizer flow velocity influences the external radiant flux only when the convective heat flux from the flame has similar values to the external radiant flux. The results of this work provide further understanding of the flammability characteristics of fire resistant fabrics in environments similar to those of future spacecrafts.

  13. Fire-Resistant Materials: Research Overview

    DOT National Transportation Integrated Search

    1996-12-01

    This report provides an overview of the research being conducted by the Federal Aviation Administration (FAA) to develop fire safe cabin materials for commercial aircraft. The objective of the Fire-Resistant Materials program is to eliminate burning ...

  14. Degradation Behavior and Accelerated Weathering of Composite Boards Produced from Waste Tetra Pak® Packaging Materials

    Treesearch

    Nural Yilgor; Coskun Kose; Evren Terzi; Aysel Kanturk Figen; Rebecca Ibach; S. Nami Kartal; Sabriye Piskin

    2014-01-01

    Manufacturing panels from Tetra Pak® (TP) packaging material might be an alternative to conventional wood-based panels. This study evaluated some chemical and physical properties as well as biological, weathering, and fire performance of panels with and without zinc borate (ZnB) by using shredded TP packaging cartons. Such packaging material, a worldwide well-known...

  15. Geoelectrical image of the subsurface for CO2 geological storage in the Changhua site, Taiwan

    NASA Astrophysics Data System (ADS)

    Chiang, C. W.; Chiao, C. H.; Yang, M. W.; Yu, C. W.; Yang, C. H.; Chen, C. C.

    2016-12-01

    Global warming has recently become an important worldwide issue. Reduction of carbon dioxide (CO2) emission is recommended by Intergovernmental Panel on Climate Change, which geological storage is one of possible way to reduce the CO2 issue. The Taichung Power Plant is a coal-fired power plant operated by the Taiwan Power Company in Taichung, Taiwan, which is the largest coal-fired power station in the world. The power plant emits approximately 40 million tons annually which is also the world's largest CO2 emitter. Geophysical techniques are presented as the most useful tool to characterize the reservoir. The electrical resistivity tool was carried out applying audio-magnetotelluric (AMT) method, which could provide the depth resolution for evaluating the subsurface. A first survey of 20 AMT soundings was acquired to study the viability of the method to characterize the subsurface. Stations were deployed at approximately 500 m intervals and the data were recorded in the frequency range of 104-100 Hz. The dimensionality analysis proved the validity of the 1-D or 2-D assumption. The visualized model shows a layered electrical resistivity structure from shallow to depth of 3000 m. The preliminary result corresponds to seismic reflection and geological investigations that suggests a simple geological structure without complex geological processes in the area. It could be a suitable site for geological storage.

  16. Fire resistant polyamide based on 1-(diorganooxyphosphonyl)methyl-2,4- and -2,6diamino benzene

    NASA Technical Reports Server (NTRS)

    Mikroyannidis, J. A. (Inventor); Kourtides, D. A. (Inventor)

    1986-01-01

    1-(Diorganooxyphosphonyl)methyl2,4- and-2,6diamino benzenes are reacted with polyacylhalides and optionally comonomers to produce polyamides which have desirable heat and fire resistance properties. These polymers are used to form fibers and fabrics where fire resistance properties are important, e.g., aircraft equipment and structures.

  17. Fire resistance of exposed wood members

    Treesearch

    Robert H. White

    2004-01-01

    Fire resistance data on exposed wood beams and columns are plentiful, but few studies have been done on exposed wood members in tension and in decks. To provide data to verify the application of a new calculation procedure, a limited series of fire resistance tests were conducted on wood members loaded in tension and on exposed wood decks.

  18. Highly Flexible Superhydrophobic and Fire-Resistant Layered Inorganic Paper.

    PubMed

    Chen, Fei-Fei; Zhu, Ying-Jie; Xiong, Zhi-Chao; Sun, Tuan-Wei; Shen, Yue-Qin

    2016-12-21

    Traditional paper made from plant cellulose fibers is easily destroyed by either liquid or fire. In addition, the paper making industry consumes a large amount of natural trees and thus causes serious environmental problems including excessive deforestation and pollution. In consideration of the intrinsic flammability of organics and minimizing the effects on the environment and creatures, biocompatible ultralong hydroxyapatite nanowires are an ideal building material for inorganic fire-resistant paper. Herein, a new kind of free-standing, highly flexible, superhydrophobic, and fire-resistant layered inorganic paper has been successfully prepared using ultralong hydroxyapatite nanowires as building blocks after the surface modification with sodium oleate. During the vacuum filtration, ultralong hydroxyapatite nanowires assemble into self-roughened setalike microfibers, avoiding the tedious fabrication process to construct the hierarchical structure; the self-roughened microfibers further form the inorganic paper with a nacrelike layered structure. We have demonstrated that the layered structure can significantly improve the resistance to mechanical destruction of the as-prepared superhydrophobic paper. The as-prepared superhydrophobic and fire-resistant inorganic paper shows excellent nonflammability, liquid repellency to various commercial drinks, high thermal stability, and self-cleaning property. Moreover, we have explored the potential applications of the superhydrophobic and fire-resistant inorganic paper as a highly effective adsorbent for oil/water separation, fire-shielding protector, and writing paper.

  19. Analytical modeling of fire growth on fire-resistive wood-based materials with changing conditions

    Treesearch

    Mark A. Dietenberger

    2006-01-01

    Our analytical model of fire growth for the ASTM E 84 tunnel, which simultaneously predicts heat release rate, flame-over area, and pyrolysis area as functions of time for constant conditions, was documented in the 2001 BCC Symposium for different treated wood materials. The model was extended to predict ignition and fire growth on exterior fire-resistive structures...

  20. Flash-Fire Propensity and Heat-Release Rate Studies of Improved Fire Resistant Materials

    NASA Technical Reports Server (NTRS)

    Fewell, L. L.

    1978-01-01

    Twenty-six improved fire resistant materials were tested for flash-fire propensity and heat release rate properties. The tests were conducted to obtain a descriptive index based on the production of ignitable gases during the thermal degradation process and on the response of the materials under a specific heat load.

  1. Determination of the fire hazards of mine materials using a radiant panel.

    PubMed

    Harteis, S P; Litton, C D; Thomas, R A

    2016-01-01

    The objective of this study was to develop a laboratory-scale method to rank the ignition and fire hazards of commonly used underground mine materials and to eliminate the need for the expensive large-scale tests that are currently being used. A radiant-panel apparatus was used to determine the materials' relevant thermal characteristics: time to ignition, critical heat flux for ignition, heat of gasification, and mass-loss rate. Three thermal parameters, TRP , TP1 and TP4 , were derived from the data, then developed and subsequently used to rank the combined ignition and fire hazards of the combustible materials from low hazard to high hazard. The results compared favorably with the thermal and ignition hazards of similar materials reported in the literature and support this approach as a simpler one for quantifying these combustible hazards.

  2. Improved fire-resistant coatings

    NASA Technical Reports Server (NTRS)

    Hutt, J. B.; Stuart, J. W.

    1971-01-01

    Water-base coatings containing potassium silicate show improvement in areas of quick air-drying, crack, craze, and abrasion resistance, adherence, and leach resistance. Coatings are useful as thermal-barrier layers in furnaces, and as general purpose fire resistant surfaces where vapor impermeability is not a requirement.

  3. 46 CFR 199.175 - Survival craft and rescue boat equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... breakage-resistant material. (9) Fire extinguisher. The fire extinguisher must be approved under approval series 162.028. The fire extinguisher must be type B-C, size II, or larger. Two type B-C, size I fire... portions of the hull. (4) Bucket. The bucket must be made of corrosion-resistant material and should either...

  4. Decay and termite resistance, water absorption and swelling of thermally compressed wood panels

    Treesearch

    Oner Unsal; S. Nami Kartal; Zeki Candan; Rachel A. Arango; Carol A. Clausen; Frederick Green

    2009-01-01

    This study evaluated decay and termite resistance of thermally compressed pine wood panels under pressure at either 5 or 7 MPa and either 120 or 150 °C for 1 h. Wood specimens from the panels were exposed to laboratory decay resistance by using the wood degrading fungi, Gloeophyllum trabeum and Trametes versicolor. The thermal compression process caused increases in...

  5. Fire-retardant decorative inks for aircraft interiors

    NASA Technical Reports Server (NTRS)

    Nir, Z.; Mikroyannidis, J. A.; Kourtides, D. A.

    1984-01-01

    Commercial and experimental fire retardants were screened for possible use wiith acrylic printing inks on aircraft interior sandwich panels. The fire retardants were selected according to their physical properties and thermostabilities. Thermostabilities were determined by thermogravimetric analysis and differential scanning calorimetry. A criterion was then established for selecting the more stable agent. Results show that some of the bromine-containing fire retardants are more thermostable than the acrylic ink, alone, used as a control. Also, the bromine-containing fire retardants yield even better limiting oxygen index values when tested after adding carboxy-terminated butadiene acrylonitrile (CTBN) rubber.

  6. Coal-fired high performance power generating system. Quarterly progress report, October 1, 1994--December 31, 1994

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-08-01

    This report covers work carried out under Task 3, Preliminary R and D, under contract DE-AC22-92PC91155, {open_quotes}Engineering Development of a Coal-Fired High Performance Power Generation System{close_quotes} between DOE Pittsburgh Energy Technology Center and United Technologies Research Center. The goals of the program are to develop a coal-fired high performance power generation system (HIPPS) by the year 2000 that is capable of (1) > 47% thermal efficiency; (2) NO{sub x}, SO{sub x} and particulates {<=}25% NSPS; (3) cost {>=}65% of heat input; (4) all solid wastes benign. In our design consideration, we have tried to render all waste streams benign andmore » if possible convert them to a commercial product. It appears that vitrified slag has commercial values. If the flyash is reinjected through the furnace, along with the dry bottom ash, then the amount of the less valuable solid waste stream (ash) can be minimized. A limitation on this procedure arises if it results in the buildup of toxic metal concentrations in either the slag, the flyash or other APCD components. We have assembled analytical tools to describe the progress of specific toxic metals in our system. The outline of the analytical procedure is presented in the first section of this report. The strengths and corrosion resistance of five candidate refractories have been studied in this quarter. Some of the results are presented and compared for selected preparation conditions (mixing, drying time and drying temperatures). A 100 hour pilot-scale stagging combustor test of the prototype radiant panel is being planned. Several potential refractory brick materials are under review and five will be selected for the first 100 hour test. The design of the prototype panel is presented along with some of the test requirements.« less

  7. The effect of fire retardants on the fire response characteristics of cellulosic materials

    NASA Technical Reports Server (NTRS)

    Hilado, C. J.; Brauer, D. P.

    1978-01-01

    The resistance to ignition of fire retardant-treated wood, cotton, and cellulose insulation was studied. The proprietary composition used to treat wood was found to increase resistance to ignition and to reduce smoke toxicity. Cotton treated with boric acid (added by padding on or by vapor phase process) was found to have increased resistance to ignition and decreased smoke toxicity. Boric acid increased the resistance of cellulose insulation to ignition but also slightly increased the smoke toxicity.

  8. Organizational barriers

    Treesearch

    Kenneth S. Blonski

    1995-01-01

    One of the traditional roles that prescribed fire has played in the fire management arena is reduction of hazardous fuel buildups under controlled, well-defined environmental conditions. However, our ability to use this tool effectively is blocked by many barriers. The preceding panel discussion about the causes of limited success in implementing prescribed burning...

  9. 46 CFR 177.410 - Structural fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... not considered high fire hazards areas (galleys) as long as they do not contain medium to high heat... must be located as far as practical from heat sources. Internal combustion engine exhausts, boiler and... be lined with noncombustible panels or insulation approved in accordance with § 164.009 in subchapter...

  10. 46 CFR 177.410 - Structural fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... considered high fire hazards areas (galleys) as long as they do not contain medium to high heat appliances... must be located as far as practical from heat sources. Internal combustion engine exhausts, boiler and... be lined with noncombustible panels or insulation approved in accordance with § 164.009 in subchapter...

  11. 46 CFR 177.410 - Structural fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... considered high fire hazards areas (galleys) as long as they do not contain medium to high heat appliances... must be located as far as practical from heat sources. Internal combustion engine exhausts, boiler and... be lined with noncombustible panels or insulation approved in accordance with § 164.009 in subchapter...

  12. 46 CFR 177.410 - Structural fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... considered high fire hazards areas (galleys) as long as they do not contain medium to high heat appliances... must be located as far as practical from heat sources. Internal combustion engine exhausts, boiler and... be lined with noncombustible panels or insulation approved in accordance with § 164.009 in subchapter...

  13. 46 CFR 177.410 - Structural fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... not considered high fire hazards areas (galleys) as long as they do not contain medium to high heat... must be located as far as practical from heat sources. Internal combustion engine exhausts, boiler and... be lined with noncombustible panels or insulation approved in accordance with § 164.009 in subchapter...

  14. 76 FR 69163 - Airworthiness Directives; Fokker Services B.V. Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-08

    ... fuel fire shut-off valve indication logic had been introduced during production on a limited number of..., of the crossfeed indication logic and power supply and of the fuel fire shut-off valve indication logic. * * * * * Required actions also include modifying the overhead panel (introduce provisions for a...

  15. Electrical Resistivity Tomography for coal fire mapping over Jharia coal field, India

    NASA Astrophysics Data System (ADS)

    Pal, S. K.; Kumar, S.; Bharti, A. K.; Pathak, V. K.; Kumar, R.

    2016-12-01

    Over the decades, coal fires are serious global concern posing grievous hazards to the valuable energy resources, local environments and human life. The coal seam and coal mine fires may be initiated due to improper mining activities, exothermic reactions, lighting, forest fire and other anthropic activities, which burn the coal and may continue underground for decades. The burning of concealed coal seams is a complex process involving numerous ill-defined parameters. Generally, the coal exhibits resistivity of 100 to 500Ωm at normal temperature conditions. During the pyrolysis process, at temperatures greater than 6500C coal became a good conductor with a resistivity of approximately 1 Ωm. The present study deals with the mapping of coal fire over Jharia coal field, India using Electrical Resistivity Tomography (ERT). A state-of-the-art 61-channel 64 electrode FlashRES-Universal ERT data acquisition system has been used for data acquisition in the field. The ERT data have been collected using Gradient array and processed in FlashRES Universal survey data checking program for removing noisy data. Then, filtered output data have been inverted using a 2.5D resistivity inversion program. Low resistivity anomalies over 80m-125m and 320m-390m along the profile are inferred to be active coal fire in seam- XVI at a depth of 25m -35m(Figure 1). High resistivity anomaly over 445m - 510m at a depth of 25m -35m has been delineated, due to void associated with complete combustion of seam- XVI coal, followed by char and ash formation resulting from the coal seam fire. Results prove the efficacy of the ERT study comprising Gradient array for coal fire mapping over, Jharia coal field, India.

  16. Resistance is not futile: The response of hardwoods to fire-caused wounding

    Treesearch

    Elaine Kennedy Sutherland; Kevin Smith

    2000-01-01

    Fires wound trees; but not all of them, and not always. Specific fire behavior and differences among tree species and individual trees produce variable patterns of wounding and wound response. Our work focuses on the relationships between fire behavior and tree biology to better understand how hardwood trees resist injury to the lower stem and either survive or succumb...

  17. Fire performance and decay resistance of solid wood and plywood treated with quaternary ammonia compounds and common fire retardants

    Treesearch

    Evren Terzi; S. Nami Kartal; Robert White; Katsumi Shinoda; Yuji Imamura

    2010-01-01

    In this study, the fire performance and decay resistance of solid wood and plywood treated with quaternary ammonia compounds (didecyl dimethyl ammonium chloride (DDAC) and didecyl dimethyl ammonium tetrafluoroborate (DBF)) were compared with the performance of untreated control specimens and specimens treated with common fire retardants ((monoammonium phosphate (MAP),...

  18. Mixture of natural fiber with gypsum to improve the fire resistance rating of a fire door: The effect of kapok fiber

    NASA Astrophysics Data System (ADS)

    Azieyanti, N. A.; Hakim, Alif; Hasini, Hasril

    2017-10-01

    A composite mixture of gypsum and natural fibers has been considered in this study to enhance the fire resistance rating of a fire door. Previously the materials used to make a fire door are gypsum and fiber wool where it acts as a protective coating. Normally this fire door must be compact and able to close on its own. Natural fibers have the ability to replace glass fiber cotton because of its features that are available in fiber glass wool. When using fiberglass, it can cause health problem once it is swallowed and inhaled, and may remain in the lungs indefinitely. It also can contribute to lungs cancer. Kapok fiber has been used in this experiment as natural fibers. The objective of the experiment is to analyze the fire resistant rating of the composite mixture of gypsum with kapok fiber. The scopes of the experiment consist of a preparation of composite mixture samples of gypsum with kapok fiber with different composition and thickness, and the fabrication of a fire resistant testing furnace. A testing of samples which were conducted in accordance with the standard MS 1073: PART 2:1996.

  19. Numerical Analysis on Tensile Properties of Grout-filled Splice Sleeve Rebars under ISO 834 Standard Fire

    NASA Astrophysics Data System (ADS)

    Liu, Yong Jun; Li, Chao; Zhou, When Jun

    2018-06-01

    This paper presents some numerical simulation results of tensile properties of reinforcing bars spliced by grout-filled coupling sleeves under fire conditions to identify the effect of load ratio on fire resistance time of spliced reinforcing bars, which provide a useful base for predicting structural behaviors of pre-cast reinforced concrete buildings in fires. A spliced rebar system investigated in this paper consists of two equal-diameter steel reinforcing bars with 25mm diameter and a straight coupling sleeve with 50mm outer and 45mm inner diameters. As a result, the thickness of grout between steel bars and sleeves are 20mm. Firstly, the temperature distributions in steel bars connected by grout- filled coupling sleeves exposed to ISO 834 standard fire were calculated utilizing finite element analysis software ANSYS. Secondly, the stress changes in heated steel bars connected by grout-filled coupling sleeves under different constant tensile loads were calculated step by step until the rebar system failed due to fire. Thus, the fire resistant time of rebar spliced by grout-filled coupling sleeves under different axial tensile loads can be determined, further, the relationship between fire resistance time and axial tensile loads ratio can could be obtained. Finally, the fire resistant times versus axial tensile load ratios curve of grout-filled splice sleeve rebars exposed to ISO 834 standard fire is presented.

  20. Experimental investigation on temperature distribution of foamed concrete filled steel tube column under standard fire

    NASA Astrophysics Data System (ADS)

    Kado, B.; Mohammad, S.; Lee, Y. H.; Shek, P. N.; Kadir, M. A. A.

    2018-04-01

    Standard fire test was carried out on 3 hollow steel tube and 6 foamed concrete filled steel tube columns. Temperature distribution on the columns was investigated. 1500 kg/m3 and 1800 kg/m3 foamed concrete density at 15%, 20% and 25% load level are the parameters considered. The columns investigated were 2400 mm long, 139.7 mm outer diameter and 6 mm steel tube thickness. The result shows that foamed concrete filled steel tube columns has the highest fire resistance of 43 minutes at 15% load level and low critical temperature of 671 ºC at 25% load level using 1500 kg/m3 foamed concrete density. Fire resistance of foamed concrete filled column increases with lower foamed concrete strength. Foamed concrete can be used to provide more fire resistance to hollow steel column or to replace normal weight concrete in concrete filled columns. Since filling hollow steel with foamed concrete produce column with high fire resistance than unfilled hollow steel column. Therefore normal weight concrete can be substituted with foamed concrete in concrete filled column, it will reduces the self-weight of the structure because of its light weight at the same time providing the desired fire resistance.

  1. Development of fire test methods for airplane interior materials

    NASA Technical Reports Server (NTRS)

    Tustin, E. A.

    1978-01-01

    Fire tests were conducted in a 737 airplane fuselage at NASA-JSC to characterize jet fuel fires in open steel pans (simulating post-crash fire sources and a ruptured airplane fuselage) and to characterize fires in some common combustibles (simulating in-flight fire sources). Design post-crash and in-flight fire source selections were based on these data. Large panels of airplane interior materials were exposed to closely-controlled large scale heating simulations of the two design fire sources in a Boeing fire test facility utilizing a surplused 707 fuselage section. Small samples of the same airplane materials were tested by several laboratory fire test methods. Large scale and laboratory scale data were examined for correlative factors. Published data for dangerous hazard levels in a fire environment were used as the basis for developing a method to select the most desirable material where trade-offs in heat, smoke and gaseous toxicant evolution must be considered.

  2. Fire-retardant decorative inks for aircraft interiors

    NASA Technical Reports Server (NTRS)

    Kourtides, D. A.; Nir, Z.; Mikroyannidis, J. A.

    1985-01-01

    Commercial and experimental fire retardants were screened as potential fire retardants for acrylic printing inks used on aircraft interior sandwich panels. The fire retardants are selected according to their physical properties and their thermostabilities. A criterion for selecting a more stable fire retardant is established. Thermogravimetric analysis (TGA) and differential scanning calorimetry (DSC) are used to determine thermostabilities. Results show that the fire retardant formulations are more thermally stable than the acrylic ink control. It is determined that an ink formulation containing a brominated phenol and carboxy-terminated butadiene acrylonitrile which has been modified with a brominated polymeric additive (BPA), yields the highest limiting oxygen index (LOI) of all the compounds tested. All of the fire-retardant formulations have a higher oxygen index than the baseline acrylic ink.

  3. Enhancing pathogen identification in patients with meningitis and a negative Gram stain using the BioFire FilmArray(®) Meningitis/Encephalitis panel.

    PubMed

    Wootton, Susan H; Aguilera, Elizabeth; Salazar, Lucrecia; Hemmert, Andrew C; Hasbun, Rodrigo

    2016-04-21

    Meningitis with a negative cerebrospinal (CSF) Gram stain represents a diagnostic and therapeutic challenge. The purpose of our study was to evaluate the performance of the BioFire FilmArray(®) Meningitis/Encephalitis (FA ME) panel in patients presenting with community-acquired meningitis with a negative Gram stain. CSF from 48 patients with community-acquired meningitis with a negative Gram stain admitted to four hospitals in Houston, TX underwent additional testing by the FA ME. FA ME results were compared to results obtained as part of routine evaluation. The panel detected pathogens not previously identified in 11 (22.9 %) of 48, but did not detect pathogens identified by standard technique (West Nile virus, Histoplasma) in 5 (15.2 %) patients. Rapid testing for the most common pathogens causing meningitis will aid in the diagnosis and treatment of patients with meningitis.

  4. Self-diagnosis of damage in fibrous composites using electrical resistance measurements

    NASA Astrophysics Data System (ADS)

    Kang, Ji Ho; Paty, Spandana; Kim, Ran Y.; Tandon, G. P.

    2006-03-01

    The objective of this research was to develop a practical integrated approach using extracted features from electrical resistance measurements and coupled electromechanical models of damage, for in situ damage detection and sensing in carbon fiber reinforced plastic (CFRP) composite structures. To achieve this objective, we introduced specific known damage (in terms of type, size, and location) into CFRP laminates and established quantitative relationships with the electrical resistance measurements. For processing of numerous measurement data, an autonomous data acquisition system was devised. We also established a specimen preparation procedure and a method for electrode setup. Coupon and panel CFRP laminate specimens with several known damage were tested and post-processed with the measurement data. Coupon specimens with various sizes of artificial delaminations obtained by inserting Teflon film were manufactured and the resistance was measured. The measurement results showed that increase of delamination size led to increase of resistance implying that it is possible to sense the existence and size of delamination. Encouraged by the results of coupon specimens, we implemented the measurement system on panel specimens. Three different quasi-isotropic panels were designed and manufactured: a panel with artificial delamination by inserting Teflon film at the midplane, a panel with artificial delamination by inserting Teflon film between the second and third plies from the surface, and an undamaged panel. The first two panels were designed to determine the feasibility of detecting delamination using the developed measurement system. The third panel had no damage at first, and then three different sizes of holes were drilled at a chosen location. Panels were prepared using the established procedures with six electrode connections on each side making a total of twenty-four electrode connections for a panel. All possible pairs of electrodes were scanned and the resistance was measured for each pair. The measurement results showed the possibility of the established measurement system for an in-situ damage detection method for CFRP composite structures.

  5. Role of Firing Temperature, Sheet Resistance, and Contact Area in Contact Formation on Screen-Printed Metal Contact of Silicon Solar Cell

    NASA Astrophysics Data System (ADS)

    Ahmad, Samir Mahmmod; Leong, Cheow Siu; Sopian, K.; Zaidi, Saleem H.

    2018-03-01

    Formation of an Ohmic contact requires a suitable firing temperature, appropriate doping profile, and contact dimensions within resolution limits of the screen-printing process. In this study, the role of the peak firing temperature in standard rapid thermal annealing (RTA) six-zone conveyor belt furnace (CBF) and two inexpensive alternate RTA systems [a custom-designed, three-zone, 5″-diameter quartz tube furnace (QTF) and a tabletop, 3″-diameter rapid thermal processing (RTP)] has been investigated. In addition, the role of sheet resistance and contact area in achieving low-resistance ohmic contacts has been examined. Electrical measurements of ohmic contacts between silver paste/ n +-emitter layer with varying sheet resistances and aluminum paste/ p-doped wafer were carried out in transmission line method configuration. Experimental measurements of the contact resistivity ( ρ c) exhibited the lowest values for CBF at 0.14 mΩ cm2 for Ag and 100 mΩ cm2 for Al at a peak firing temperature of 870°C. For the QTF configuration, lowest measured contact resistivities were 3.1 mΩ cm2 for Ag and 74.1 mΩ cm2 for Al at a peak firing temperature of 925°C. Finally, for the RTP configuration, lowest measured contact resistivities were 1.2 mΩ cm2 for Ag and 68.5 mΩ cm2 for Al at a peak firing temperature of 780°C. The measured contact resistivity exhibits strong linear dependence on sheet resistance. The contact resistivity for Ag decreases with contact area, while for Al the opposite behavior is observed.

  6. Study to develop improved fire resistant aircraft passenger seat materials, phase 2

    NASA Technical Reports Server (NTRS)

    Duskin, F. E.; Shook, W. H.; Trabold, E. L.; Spieth, H. H.

    1978-01-01

    Fire tests are reported of improved materials in multilayered combinations representative of cushion configurations. Tests were conducted to determine their thermal, smoke, and fire resistance characteristics. Additionally, a source fire consisting of one and one-half pounds of newspaper in a tented configuration was developed. Finally, a preliminary seat specification was written based upon materials data and general seat design criteria.

  7. Thermal Response of UHMWPE Materials in a Flash Flame Test Environment

    DTIC Science & Technology

    2014-11-13

    Evaluation of Flame Resistant Clothing for Protection Against Fire Simulations Using an Instrumented Manikin. Several UHMWPE fabrics were tested underneath...PROTECTIVE CLOTHING COTTON FLASH FLAMES UNDERGARMENTS TEST AND EVALUATION FABRICS FLAME TESTING FIRE ...PROTECTION FIRE RESISTANT TEXTILES UHMWPE(ULTRA HIGH MOLECULAR WEIGHT POLYETHYLENE

  8. Fire intensity impacts on post-fire temperate coniferous forest net primary productivity

    NASA Astrophysics Data System (ADS)

    Sparks, Aaron M.; Kolden, Crystal A.; Smith, Alistair M. S.; Boschetti, Luigi; Johnson, Daniel M.; Cochrane, Mark A.

    2018-02-01

    Fire is a dynamic ecological process in forests and impacts the carbon (C) cycle through direct combustion emissions, tree mortality, and by impairing the ability of surviving trees to sequester carbon. While studies on young trees have demonstrated that fire intensity is a determinant of post-fire net primary productivity, wildland fires on landscape to regional scales have largely been assumed to either cause tree mortality, or conversely, cause no physiological impact, ignoring the impacted but surviving trees. Our objective was to understand how fire intensity affects post-fire net primary productivity in conifer-dominated forested ecosystems on the spatial scale of large wildland fires. We examined the relationships between fire radiative power (FRP), its temporal integral (fire radiative energy - FRE), and net primary productivity (NPP) using 16 years of data from the MOderate Resolution Imaging Spectrometer (MODIS) for 15 large fires in western United States coniferous forests. The greatest NPP post-fire loss occurred 1 year post-fire and ranged from -67 to -312 g C m-2 yr-1 (-13 to -54 %) across all fires. Forests dominated by fire-resistant species (species that typically survive low-intensity fires) experienced the lowest relative NPP reductions compared to forests with less resistant species. Post-fire NPP in forests that were dominated by fire-susceptible species were not as sensitive to FRP or FRE, indicating that NPP in these forests may be reduced to similar levels regardless of fire intensity. Conversely, post-fire NPP in forests dominated by fire-resistant and mixed species decreased with increasing FRP or FRE. In some cases, this dose-response relationship persisted for more than a decade post-fire, highlighting a legacy effect of fire intensity on post-fire C dynamics in these forests.

  9. Numerical simulation on behaviour of timber-concrete composite beams in fire

    NASA Astrophysics Data System (ADS)

    Du, Hao; Hu, Xiamin; Zhang, Bing; Minli, Yao

    2017-08-01

    This paper established sequentially coupled thermal-mechanical models of timber--concrete composite (TCC) beams by finite element software ANSYS to investigate the fire resistance of TCC beam. Existing experimental results were used to verify the coupled thermal-mechanical model. The influencing parameters consisted of the width of timber beam, the thickness of the concrete slab and the timber board. Based on the numerical results, the effects of these parameters on fire resistance of TCC beams were investigated in detail. The results showed that modeling results agreed well with test results, and verified the reliability of the finite element model. The width of the timber beam had a significant influence on the fire resistance of TCC beams. The fire resistance of TCC beams would be enhanced by increasing the width of timber beam, the thickness of concrete slab and the timber board.

  10. Candidate materials for advanced fire-resistant photovoltaic modules

    NASA Technical Reports Server (NTRS)

    Sugimura, R. S.; Otth, D. H.; Ross, R. G., Jr.; Arnett, J. C.; Samuelson, G.

    1985-01-01

    A cooperative, cost-sharing research effort to develop a technology base required to construct fire-ratable photovoltaic modules has resulted in the identification of several high-temperature, back-surface candidate materials capable of raising the fire-resistance of modules using hydrocarbon encapsulants to Class A and B levels. Advanced experimental module configurations have been developed using back surfaces consisting of Kapton, Tedlar laminates, metal-foils, and fiberglass materials with high-temperature coatings. Test results (October 1984; March 1985; May 1985; and October 1985) indicate that several of these advanced module configurations are capable of achieving Class B fire-resistance levels, while a few configurations can achieve Class A levels. The paper summarizes activities to date, discussing flammability failure mechanisms, time-temperature profiles, and results of Block V environmental exposure tests of a candidate material suitable for both Class B and Class A fire-resistance levels.

  11. 77 FR 57481 - Special Conditions: Embraer S.A., Models EMB-135 and EMB-145 Series; Airplane Seats with Non...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-18

    ... Series; Airplane Seats with Non-Traditional, Large, Non-Metallic Panels AGENCY: Federal Aviation... have a novel or unusual design feature associated with the airplane seats that have non-traditional, large, non-metallic panels that would affect survivability during a post-crash fire event. The...

  12. Effect of various fire retardants on surface roughness of plywood

    Treesearch

    Nadir Ayrilmis; Suleyman Korkut; Ercan Tanritanir; Jerrold E. Winandy; Salim Hiziroglu

    2006-01-01

    In this study the surface roughness of plywood treated with various fire retardants was investigated. Commercially manufactured veneer of Akaba wood (Tetraberlinia bifoliolata) was treated with borax, boric acid, monoammonium phosphate and diammonium phosphate, then experimental plywood panels were made from these veneer sheets. A stylus method was employed to evaluate...

  13. Prescribed Fire: The Influence of Site Visits on Citizen Attitudes

    ERIC Educational Resources Information Center

    Toman, Eric; Shindler, Bruce; Reed, Michelle

    2004-01-01

    This research employed a panel design to measure the effect of site visits on public perceptions of prescribed fire. On-site survey questions were devised to compare answers to a mail questionnaire previously completed by the same respondents. Questions were designed to examine how site visits influence public opinion and affect acceptance of…

  14. Reverberatory screen for a radiant burner

    DOEpatents

    Gray, Paul E.

    1999-01-01

    The present invention relates to porous mat gas fired radiant burner panels utilizing improved reverberatory screens. The purpose of these screens is to boost the overall radiant output of the burner relative to a burner using no screen and the same fuel-air flow rates. In one embodiment, the reverberatory screen is fabricated from ceramic composite material, which can withstand higher operating temperatures than its metallic equivalent. In another embodiment the reverberatory screen is corrugated. The corrugations add stiffness which helps to resist creep and thermally induced distortions due to temperature or thermal expansion coefficient differences. As an added benefit, it has been unexpectedly discovered that the corrugations further increase the radiant efficiency of the burner. In a preferred embodiment, the reverberatory screen is both corrugated and made from ceramic composite material.

  15. Putative resistance gene markers associated with quantitative trait loci for fire blight resistance in Malus ‘Robusta 5’ accessions

    PubMed Central

    2012-01-01

    Background Breeding of fire blight resistant scions and rootstocks is a goal of several international apple breeding programs, as options are limited for management of this destructive disease caused by the bacterial pathogen Erwinia amylovora. A broad, large-effect quantitative trait locus (QTL) for fire blight resistance has been reported on linkage group 3 of Malus ‘Robusta 5’. In this study we identified markers derived from putative fire blight resistance genes associated with the QTL by integrating further genetic mapping studies with bioinformatics analysis of transcript profiling data and genome sequence databases. Results When several defined E.amylovora strains were used to inoculate three progenies from international breeding programs, all with ‘Robusta 5’ as a common parent, two distinct QTLs were detected on linkage group 3, where only one had previously been mapped. In the New Zealand ‘Malling 9’ X ‘Robusta 5’ population inoculated with E. amylovora ICMP11176, the proximal QTL co-located with SNP markers derived from a leucine-rich repeat, receptor-like protein ( MxdRLP1) and a closely linked class 3 peroxidase gene. While the QTL detected in the German ‘Idared’ X ‘Robusta 5’ population inoculated with E. amylovora strains Ea222_JKI or ICMP11176 was approximately 6 cM distal to this, directly below a SNP marker derived from a heat shock 90 family protein gene ( HSP90). In the US ‘Otawa3’ X ‘Robusta5’ population inoculated with E. amylovora strains Ea273 or E2002a, the position of the LOD score peak on linkage group 3 was dependent upon the pathogen strains used for inoculation. One of the five MxdRLP1 alleles identified in fire blight resistant and susceptible cultivars was genetically associated with resistance and used to develop a high resolution melting PCR marker. A resistance QTL detected on linkage group 7 of the US population co-located with another HSP90 gene-family member and a WRKY transcription factor previously associated with fire blight resistance. However, this QTL was not observed in the New Zealand or German populations. Conclusions The results suggest that the upper region of ‘Robusta 5’ linkage group 3 contains multiple genes contributing to fire blight resistance and that their contributions to resistance can vary depending upon pathogen virulence and other factors. Mapping markers derived from putative fire blight resistance genes has proved a useful aid in defining these QTLs and developing markers for marker-assisted breeding of fire blight resistance. PMID:22471693

  16. Remote monitoring of a Fire Protection System

    NASA Astrophysics Data System (ADS)

    Bauman, Steven; Vermeulen, Tom; Roberts, Larry; Matsushige, Grant; Gajadhar, Sarah; Taroma, Ralph; Elizares, Casey; Arruda, Tyson; Potter, Sharon; Hoffman, James

    2011-03-01

    Some years ago CFHT proposed developing a Remote Observing Environment aimed at producing Science Observations at their Observatory Facility on Mauna Kea from their Headquarters facility in Waimea, HI. This Remote Observing Project commonly referred to as OAP (Observatory Automation Project) was completed at the end of January 2011 and has been providing the majority of Science Data since. My poster will discuss the upgrades to the existing fire alarm protection system. With no one at the summit during nightly operations, the observatory facility required automated monitoring of the facility for safety to personnel and equipment in the case of a fire. An addressable analog fire panel was installed which utilizes digital communication protocol (DCP), intelligent communication with other devices, and an RS-232 interface which provides feedback and real-time monitoring of the system. Using the interface capabilities of the panel, it provides notifications when heat detectors, smoke sensors, manual pull stations, or the main observatory computer room fire suppression system has been activated. The notifications are sent out as alerts to staff in the form of test massages and emails and the observing control GUI interface alerts the remote telescope operator with a map showing the location of the fire occurrence and type of device that has been triggered. And all of this was accomplished without the need for an outside vendor to monitor the system and facilitate warnings or notifications regarding the system.

  17. Evaluation of Precast Panels for Airfield Pavement Repair. Phase 1: System Optimization and Test Section Construction

    DTIC Science & Technology

    2013-06-01

    boundary was also considered. The panel must be slightly smaller than the repair area to allow the panel to be installed easily with little resistance ...beam between simple supports that offer no resistance and is more flexible. The actual support conditions are somewhere in between since the...slenderness of the keyway components, and thin bolt tab were not sufficient to resist rotation. The keyway was removed since it offered little structural

  18. [Study on discrimination of varieties of fire resistive coating for steel structure based on near-infrared spectroscopy].

    PubMed

    Xue, Gang; Song, Wen-qi; Li, Shu-chao

    2015-01-01

    In order to achieve the rapid identification of fire resistive coating for steel structure of different brands in circulating, a new method for the fast discrimination of varieties of fire resistive coating for steel structure by means of near infrared spectroscopy was proposed. The raster scanning near infrared spectroscopy instrument and near infrared diffuse reflectance spectroscopy were applied to collect the spectral curve of different brands of fire resistive coating for steel structure and the spectral data were preprocessed with standard normal variate transformation(standard normal variate transformation, SNV) and Norris second derivative. The principal component analysis (principal component analysis, PCA)was used to near infrared spectra for cluster analysis. The analysis results showed that the cumulate reliabilities of PC1 to PC5 were 99. 791%. The 3-dimentional plot was drawn with the scores of PC1, PC2 and PC3 X 10, which appeared to provide the best clustering of the varieties of fire resistive coating for steel structure. A total of 150 fire resistive coating samples were divided into calibration set and validation set randomly, the calibration set had 125 samples with 25 samples of each variety, and the validation set had 25 samples with 5 samples of each variety. According to the principal component scores of unknown samples, Mahalanobis distance values between each variety and unknown samples were calculated to realize the discrimination of different varieties. The qualitative analysis model for external verification of unknown samples is a 10% recognition ration. The results demonstrated that this identification method can be used as a rapid, accurate method to identify the classification of fire resistive coating for steel structure and provide technical reference for market regulation.

  19. Life testing of a nine-couple hybrid thermoelectric panel

    NASA Technical Reports Server (NTRS)

    Bifano, W. J.

    1973-01-01

    Life test data are presented for a nine couple thermoelectric panel of hybrid couples tested at an average hot junction temperature of 840 C (1113 K). In the hybrid couple, a hollow cylinder of p-type Si-Ge is used to encapsulate a segmented PbTe/Si-Ge n-leg. The output power and internal resistance of the panel as well as the resistances of the individual hybrid couples are presented as functions of test time covering a period of more than 4200 hours. Test results indicated improved stability relative to hybrid couples tested at higher temperatures. Thermal cycling of the panel resulted in an order of magnitude increase in room temperature resistance. However, very little change in resistance at operating temperatures was noted following the thermal cycles.

  20. Identification of novel strain-specific and environment-dependent minor QTLs linked to fire blight resistance in apples

    USDA-ARS?s Scientific Manuscript database

    Since its first report almost 200 years ago, fire blight, caused by the gram negative bacterium Erwinia amylovora, has threatened apple and pear production globally. Identifying novel genes and their functional alleles is a prerequisite to developing apple cultivars with enhanced fire blight resist...

  1. 14 CFR 23.853 - Passenger and crew compartment interiors.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... constructed of at least fire resistant materials and must contain fires likely to occur in it under normal use... Design and Construction Fire Protection § 23.853 Passenger and crew compartment interiors. For each compartment to be used by the crew or passengers: (a) The materials must be at least flame-resistant; (b...

  2. Development of Self Fire Retardant Melamine-Animal Glue Formaldehyde (MGF) Resin for the Manufacture of BWR Ply Board

    NASA Astrophysics Data System (ADS)

    Khatua, Pijus Kanti; Dubey, Rajib Kumar; Roymahapatra, Gourisankar; Mishra, Anjan; Shahoo, Shadhu Charan; Kalawate, Aparna

    2017-10-01

    Wood is one of the most sustainable, naturally growing materials that consist mainly of combustible organic carbon compounds. Since plywood are widely used nowadays especially in buildings, furniture and cabinets. Too often the fire behavior of ply-board may be viewed as a drawback. Amino-plastic based thermosetting resin adhesives are the important and most widely used in the plywood panel industries. The fire retardant property of wood panel products by adding animal glue as an additive in the form of MGF resin and used as substitute of melamine for manufacture of plywood. Environment concerns and higher cost of petroleum based resins have resulted in the development of technologies to replace melamine partially by biomaterials for the manufacturing of resin adhesive. Natural bio-based materials such as tannin, CNSL (cardanol), lignin, soya etc. are used as partial substitution of melamine. This article presents the development of melamine-animal glue formaldehyde resin as plywood binder. About 30 % melamine was substituted by animal glue and optimized. The different physico-mechanical and fire retardant property properties tested as per IS: 1734-1983 and IS: 5509-2000 respectively are quite satisfactory. The production of adhesive from melamine with compatible natural proteinous material is cost effective, eco-friendly and enhance the fire retardant property.

  3. Impact of Prescribed Fire and Thinning on Host Resistance to the Southern Pine Beetle: Preliminary Results of the National Fire and Fire Surrogate Study

    Treesearch

    M. Forbes Boyle; Roy L. Hedden; Thomas A. Waldrop

    2004-01-01

    The southern pine beetle ( Dendroctonus frontalis Zimm.) is considered one of the most aggressive insect pests in the Southern United States. Resistance to southern pine beetle infestations in southern pines depends largely on oleoresin flow rate and total flow. Treatments, such as prescribed fire and thinning, can be used to reduce stand infestation susceptibil-ity by...

  4. Development and testing of advanced fire-resistant photovoltaic modules

    NASA Technical Reports Server (NTRS)

    Sugimura, R. S.; Otth, D. H.; Ross, R. G., Jr.

    1985-01-01

    The evaluation of back-surface materials flammability in order to identify fire resistant module designs is examined. The fire test apparatus, burning-brand test sequence, and spread-of-flame test sequence are described. Video recordings and time-temperature profiles of module back surfaces are utilized to study the flammability failure mechanism and identify high-temperature materials. A table of flammability test results for various module designs is provided. The data reveals that 2-mil kapton, fiberglass cloth coated or impregnated with a material to plug pores, and metal foil back-surface materials achieve class A and B fire-resistance levels, and are applicable for photovoltaic module designs.

  5. Fire-Retardant and Thermally Insulating Phenolic-Silica Aerogels.

    PubMed

    Yu, Zhi-Long; Yang, Ning; Apostolopoulou-Kalkavoura, Varvara; Qin, Bing; Ma, Zhi-Yuan; Xing, Wei-Yi; Qiao, Chan; Bergström, Lennart; Antonietti, Markus; Yu, Shu-Hong

    2018-04-16

    Energy efficient buildings require materials with a low thermal conductivity and a high fire resistance. Traditional organic insulation materials are limited by their poor fire resistance and inorganic insulation materials are either brittle or display a high thermal conductivity. Herein we report a mechanically resilient organic/inorganic composite aerogel with a thermal conductivity significantly lower than expanded polystyrene and excellent fire resistance. Co-polymerization and nanoscale phase separation of the phenol-formaldehyde-resin (PFR) and silica generate a binary network with domain sizes below 20 nm. The PFR/SiO 2 aerogel can resist a high-temperature flame without disintegration and prevents the temperature on the non-exposed side from increasing above the temperature critical for the collapse of reinforced concrete structures. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Evaluation of mine fires due to spontaneous combustion in the mechanized faces of Middle Anatolian Lignite mine (OAL), case studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gueyagueler, T.; Karaman, H.

    1995-12-31

    In this paper fires due to spontaneous combustion in Middle Anatolian Lignite mine (OAL) which is the first fully mechanized underground lignite mine in Turkey, are studied. Since the installation of mechanization, due to spontaneous heating, four panel fires namely, AO1, AO2, AO3 and AO4 have broken out. During these fires, the concentrations of carbon monoxide, methane and the velocity of air are measured continuously by the Micro Minos Environmental monitoring system. For each fire, the environment where fire has started is examined and the possible causes of the fire are investigated. Also the precautions taken to extinguish the firemore » at different stages are described and the importance of the early detection of mine fire are discussed together with the limitations of the monitoring system the practical difficulties observed during the fire.« less

  7. 78 FR 76734 - Special Conditions: Bombardier Inc., Models BD-500-1A10 and BD-500-1A11 Series Airplanes; Seats...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-19

    ... Series Airplanes; Seats With Non-Traditional, Large, Non- Metallic Panels AGENCY: Federal Aviation... airplanes will have a novel or unusual design feature associated with seats that include non-traditional, large, non-metallic panels that would affect survivability during a post-crash fire event. The...

  8. Study of noise reduction characteristics of multilayered panels and dual pane windows with Helmholtz resonators

    NASA Technical Reports Server (NTRS)

    Navaneethan, R.

    1981-01-01

    The experimental noise attenuation characteristics of flat, general aviation type, multilayered panels are discussed. Experimental results of stiffened panels, damping tape, honeycomb materials and sound absorption materials are presented. Single degree of freedom theoretical models were developed for sandwich type panels with both shear resistant and non-shear resistant core material. The concept of Helmholtz resonators used in conjunction with dual panel windows in increasing the noise reduction around a small range of frequency was tested. It is concluded that the stiffening of the panels either by stiffeners or by sandwich construction increases the low frequency noise reduction.

  9. Low resistivity contacts to YBa2Cu3O(7-x) superconductors

    NASA Technical Reports Server (NTRS)

    Hsi, Chi-Shiung; Haertling, Gene H.

    1991-01-01

    Silver, gold, platinum, and palladium metals were investigated as electroding materials for the YBa2Cu3O(7-x) superconductors. Painting, embedding, and melting techniques were used to apply the electrodes. Contact resistivities were determined by: (1) type of electrode; (2) firing conditions; and (3) application method. Electrodes fired for long times exhibited lower contact resistivities than those fired for short times. Low-resistivity contacts were found for silver and gold electrodes. Silver, which made good ohmic contact to the YBa2Cu3O(7-x) superconductor with low contact resistivities was found to be the best electroding material among the materials evaluated in this investigation.

  10. Building under Cold Climates and on Permafrost. Collection of Papers from a US-Soviet Joint Seminar, Leningrad USSR.

    DTIC Science & Technology

    1980-12-01

    The panels are insulated with PSBS polyurethane foam, FRP-I. and mineral wool . In recent years, several dozen such buildings have been constructed in...vulnerable points in the walls. 37 Different plastic foams and also mineral wool sheets with synthetic binding are used in the USSR for insulating the...middle layer of the panels. Mineral wool sheets are used in the wall panels of buildings having high fire safety requirements (children’s and medical

  11. Fire Resistant Fuel for Military Compression Ignition Engines

    DTIC Science & Technology

    2013-12-04

    Turbo Diesel Maximum Power Output Figure 5. 6.5L Turbo Diesel Maximum Torque Output 40 60 80 100 120 140 160 180 1000 1200 1400 1600 1800 2000 2200...H2O & 250ppm) JP8-FRF AMA (5% H2O & 250ppm) UNCLASSIFIED 9 UNCLASSIFIED Figure 6. 6.5L Turbo Diesel Brake Specific Fuel Consumption From...mid-1980s, fire-resistant diesel fuel that self extinguished when ignited by an explosive projectile was developed. Chemically, this fire resistant

  12. Fire-Retardant Decorative Inks For Aircraft Interiors

    NASA Technical Reports Server (NTRS)

    Kourtides, D. A.; Nir, Z.; Mikroyannidis, J. A.

    1988-01-01

    Report describes testing of commercial and experimental fire retardants for incorporation into acrylic printing inks used on aircraft-interior sandwich panels. Films of acrylic ink containing fire-retardant additives prepared by casting on glass plates. Solvent evaporated in vacuum, cast films cured at 80 to 100 degree C for 30 minutes in air-circulating oven. Thermochemical properties of films examined by thermogravimetric analysis and differential scanning calorimetry (DSC). Samples of inks cast on sheets of polyvinylfloride (PVF), and their limiting oxygen indices and smoke evolution measured.

  13. Increased heat resistance in mycelia from wood fungi prevalent in forests characterized by fire: a possible adaptation to forest fire.

    PubMed

    Carlsson, Fredrik; Edman, Mattias; Holm, Svante; Eriksson, Anna-Maria; Jonsson, Bengt Gunnar

    2012-10-01

    Forest fires have been the major stand-replacing/modifying disturbance in boreal forests. To adapt to fire disturbance, different strategies have evolved. This study focuses on wood fungi, and a specific adaptation to forest fire: increased heat resistance in their mycelia. Fifteen species of wood fungi were selected and a priori sorted in two groups according to their prevalence in fire-affected environments. The fungi were cultivated on fresh wood and exposed to 100, 140, 180, 220 °C for 5, 10, 15, 20 and 25 min. under laboratory conditions. A clear difference was found among the two groups. Species prevalent in fire-affected habitats had a much higher survival rate over all combinations of time and temperature compared to species associated with other environments. Thus, the results indicate that fire adaptation in terms of increased heat resistance in mycelia occurs in some species of wood fungi. Such adaptation will influence the ecology and population dynamics of wood fungi, as well as having implications for best practices during restoration fires. Copyright © 2012 The British Mycological Society. Published by Elsevier Ltd. All rights reserved.

  14. 'Sunrise': A new early maturing fire blight resistant pear cultivar

    USDA-ARS?s Scientific Manuscript database

    'Sunrise' is a new pear (Pyrus communis L.) cultivar released by the U.S. Department of Agriculture, Agricultural Research Service. It combines a high degree of resistance to fire blight with excellent fruit quality. The sources of resistance in the pedigree are the old American cultivar, 'Seckel'...

  15. 41 CFR 102-74.360 - What are the specific accident and fire prevention responsibilities of occupant agencies?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... other hanging materials that are made of non-combustible or flame-resistant fabric; (f) Use only... resistant; (g) Cooperate with GSA to develop and maintain fire prevention programs that provide the maximum... accident and fire prevention responsibilities of occupant agencies? 102-74.360 Section 102-74.360 Public...

  16. 46 CFR 72.05-10 - Type, location, and construction of fire control bulkheads and decks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... public spaces with incombustible veneers and trim and fire resistant furnishings Staterooms and public spaces of 500 square feet or less with combustible furnishings and isolated storerooms Public spaces over... and all public spaces with incombustible veneers and trim and fire resistant furnishings 5 A-15 A-15 A...

  17. Fire and the Design of Educational Buildings. Building Bulletin 7. Sixth Edition.

    ERIC Educational Resources Information Center

    Department of Education and Science, London (England).

    This bulletin offers guidance on English school premises regulations applying to safety protection against fires in the following general areas: means of escape in case of fire; precautionary measures to prevent fire; fire warning systems and fire fighting; fire spreading speed; structures and materials resistant to fires; and damage control. It…

  18. Stronger Fire-Resistant Epoxies

    NASA Technical Reports Server (NTRS)

    Fohlen, George M.; Parker, John A.; Kumar, Devendra

    1988-01-01

    New curing agent improves mechanical properties and works at lower temperature. Use of aminophenoxycyclotriphosphazene curing agents yields stronger, more heat- and fire-resistant epoxy resins. Used with solvent if necessary for coating fabrics or casting films.

  19. Resistance of Six Wood Products Used in Paneling to Reticulitermes flavipes (Isoptera: Rhinotermitidae)

    Treesearch

    Bradford M. Kard; E.J. Mallette

    1997-01-01

    Six wood products used in wall paneling were tested for resistance to feeding damage by the eastern subterranean termite, Reticuli termesflavipes (Kollar). Alaska-cedar, Chamaecyparis nootkatensis (D. Don) Spach, fiber without wax and resin treatments normally used in paneling production was not a preferred food source in choice tests where all 6 wood products plus...

  20. Anthropometric Procedures for Protective Equipment Sizing and Design

    PubMed Central

    Hsiao, Hongwei

    2015-01-01

    Objectives This article presented four anthropometric theories (univariate, bivariate/probability distribution, multivariate, and shape-based methods) for protective equipment design decisions. Background While the significance of anthropometric information for product design is well recognized, designers continue to face challenges in selecting efficient anthropometric data processing methods and translating the acquired information into effective product designs. Methods For this study, 100 farm tractor operators, 3,718 respirator users, 951 firefighters, and 816 civilian workers participated in four studies on the design of tractor roll-over protective structures (ROPS), respirator test panels, fire truck cabs, and fall-arrest harnesses, respectively. Their anthropometry and participant-equipment interfaces were evaluated. Results Study 1 showed a need to extend the 90-cm vertical clearance for tractor ROPS in the current industrial standards to 98.3 to 101.3 cm. Study 2 indicated that current respirator test panel would have excluded 10% of the male firefighter population; a systematic adjustment to the boundaries of test panel cells was suggested. Study 3 provided 24 principal component analysis-based firefighter body models to facilitate fire truck cab design. Study 4 developed an improved gender-based fall-arrest harness sizing scheme to supplant the current unisex system. Conclusions This article presented four anthropometric approaches and a six-step design paradigm for ROPS, respirator test panel, fire truck cab, and fall-arrest harness applications, which demonstrated anthropometric theories and practices for defining protective equipment fit and sizing schemes. Applications The study provided a basis for equipment designers, standards writers, and industry manufacturers to advance anthropometric applications for product design and improve product efficacy. PMID:23516791

  1. Sampling high-altitude and stratified mating flights of red imported fire ant.

    PubMed

    Fritz, Gary N; Fritz, Ann H; Vander Meer, Robert K

    2011-05-01

    With the exception of an airplane equipped with nets, no method has been developed that successfully samples red imported fire ant, Solenopsis invicta Buren, sexuals in mating/dispersal flights throughout their potential altitudinal trajectories. We developed and tested a method for sampling queens and males during mating flights at altitudinal intervals reaching as high as "140 m. Our trapping system uses an electric winch and a 1.2-m spindle bolted to a swiveling platform. The winch dispenses up to 183 m of Kevlar-core, nylon rope and the spindle stores 10 panels (0.9 by 4.6 m each) of nylon tulle impregnated with Tangle-Trap. The panels can be attached to the rope at various intervals and hoisted into the air by using a 3-m-diameter, helium-filled balloon. Raising or lowering all 10 panels takes approximately 15-20 min. This trap also should be useful for altitudinal sampling of other insects of medical importance.

  2. Lowering of the firing voltage and reducing of the discharge delay time in alternating current plasma display panels by a discontinuous spin-coated LaB{sub 6} film on the MgO protective layer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deng, Jiang, E-mail: dj78291@163.com; Zeng, Baoqing; Zhongshan Institute, University of Electronic Science and Technology of China, 528402 zhongshan

    2014-03-15

    A spin coated LaB{sub 6} discontinuous film is covered on MgO protective layer to improve the discharge performance of alternating current plasma display panels. Under the premise of high transmittance of more than 90%, a very small amount of polycrystal LaB{sub 6} powders added in an organic solvent are chosen as the coating solution. The discharge characteristics results show that with 250 torr 5% Xe-Ne pressure, the firing voltage and discharge delay time of the test panel with LaB{sub 6}/MgO double protective layer are decreased by 13.4% and 36.5%, respectively, compared with that of conventional MgO protective layer, likely owingmore » to the low work function of LaB{sub 6.} Furthermore, the aging time of the proposed structure is comparable to that of pure MgO protective layer. Therefore, it will not increase the production costs and is highly suitable to be applied for alternating current plasma display panels with low electrical power consumption.« less

  3. Space and Missile Systems Center Standard: Space Flight Pressurized Systems

    DTIC Science & Technology

    2015-02-28

    24 5.7.2 Fire Resistant Fluids ......................................................................................... 24 5.7.3...connections. 5.1.7 Threaded Parts [5.1.7-1] All threaded parts in components shall be securely locked to resist uncoupling forces by acceptable safe... Resistant Fluids [5.7.2-1] Fire resistant or flame proof hydraulic fluid shall be used where the system design can expose hydraulic fluid to potential

  4. Compliance with Electrical and Fire Protection Standards of U.S. Controlled and Occupied Facilities in Afghanistan

    DTIC Science & Technology

    2013-07-18

    are subject to damage and abrasion (figure 5). The use of an extension cord instead of fixed wiring creates the possibility of fire , electrical shock...Medical Clinic has an adjacent warehouse that is of a higher hazard and is not separated by 1-hour fire resistance rated construction. KMC 17-May...higher hazard and is not separated by 1-hour fire resistance rated construction. DynCorp NO Awaiting USG Decision DI has not received governmental

  5. Fire-Resistant Hydrogel-Fabric Laminates: A Simple Concept That May Save Lives.

    PubMed

    Illeperuma, Widusha R K; Rothemund, Philipp; Suo, Zhigang; Vlassak, Joost J

    2016-01-27

    There is a large demand for fabrics that can survive high-temperature fires for an extended period of time, and protect the skin from burn injuries. Even though fire-resistant polymer fabrics are commercially available, many of these fabrics are expensive, decompose rapidly, and/or become very hot when exposed to high temperatures. We have developed a new class of fire-retarding materials by laminating a hydrogel and a fabric. The hydrogel contains around 90% water, which has a large heat capacity and enthalpy of vaporization. When the laminate is exposed to fire, a large amount of energy is absorbed as water heats up and evaporates. The temperature of the hydrogel cannot exceed 100 °C until it is fully dehydrated. The fabric has a low thermal conductivity and maintains the temperature gradient between the hydrogel and the skin. The laminates are fabricated using a recently developed tough hydrogel to ensure integrity of the laminate during processing and use. A thermal model predicts the performance of the laminates and shows that they have excellent heat resistance in good agreement with experiments, making them viable candidates in life saving applications such as fire-resistant blankets or apparel.

  6. Aircraft Alerting Systems Standardization Study. Volume I. Candidate System Validation and Time-Critical Display Evaluation.

    DTIC Science & Technology

    1981-01-01

    SELCAL FLT ALT ATNI AUO ALT BRK CANSELCAL OVSO CALL CONTRL ALRT _ I7CT be SPLR b 0 11CALL Figure 5.4.4-1 Pilot’s Response Panel Figure 5.4.4-2 Flight...Galley bus off 27 GLY BUS OFF A RP ELEC CYCLE SWITCH Utility bus off 28 UTIL BUS OFF A RP ELEC CYCLE SWITCH Right engine 29 R ENG HYD PUMP A RP HYD...CYCLE SWITCH hydraulic pump Left engine 30 L ENG FIRE DET A RP FIRE RP FIRE fire detector Left brake overheat 31 L BRAKE OVHT A RP BRK RP BRK Right

  7. Parametric Study of Fire Performance of Concrete Filled Hollow Steel Section Columns with Circular and Square Cross-Section

    NASA Astrophysics Data System (ADS)

    Nurfaidhi Rizalman, Ahmad; Tahir, Ng Seong Yap Mahmood Md; Mohammad, Shahrin

    2018-03-01

    Concrete filled hollow steel section column have been widely accepted by structural engineers and designers for high rise construction due to the benefits of combining steel and concrete. The advantages of concrete filled hollow steel section column include higher strength, ductility, energy absorption capacity, and good structural fire resistance. In this paper, comparison on the fire performance between circular and square concrete filled hollow steel section column is established. A three-dimensional finite element package, ABAQUS, was used to develop the numerical model to study the temperature development, critical temperature, and fire resistance time of the selected composite columns. Based on the analysis and comparison of typical parameters, the effect of equal cross-sectional size for both steel and concrete, concrete types, and thickness of external protection on temperature distribution and structural fire behaviour of the columns are discussed. The result showed that concrete filled hollow steel section column with circular cross-section generally has higher fire resistance than the square section.

  8. Fire Alarm Wallpaper Based on Fire-Resistant Hydroxyapatite Nanowire Inorganic Paper and Graphene Oxide Thermosensitive Sensor.

    PubMed

    Chen, Fei-Fei; Zhu, Ying-Jie; Chen, Feng; Dong, Li-Ying; Yang, Ri-Long; Xiong, Zhi-Chao

    2018-04-24

    Wallpaper with multiple functions, such as fire resistance and an automatic alarm in fire disasters, will be attractive for the interior decoration of houses. Herein, we report a smart fire alarm wallpaper prepared using fire-resistant inorganic paper based on ultralong hydroxyapatite nanowires (HNs) and graphene oxide (GO) thermosensitive sensors. At room temperature, the GO thermosensitive sensor is in a state of electrical insulation; however, it becomes electrically conductive at high temperatures. In a fire disaster, high temperature will rapidly remove the oxygen-containing groups of GO, leading to the transformation process of GO from an electrically insulated state into an electrically conductive one. In this way, the alarm lamp and alarm buzzer connected with the GO thermosensitive sensor will send out the alerts to people immediately for taking emergency actions. After the surface modification with polydopamine of GO (PGO), the sensitivity and flame retardancy of the GO thermosensitive sensor are further improved, resulting in a low responsive temperature (126.9 °C), fast response (2 s), and sustained working time in the flame (at least 5 min). Compared with combustible commercial wallpaper, the smart fire alarm wallpaper based on HNs and GO (or PGO) is superior owing to excellent nonflammability and high-temperature resistance of HNs, which can protect the GO (or PGO) thermosensitive sensor from the flames. The smart fire alarm wallpaper can be processed into various shapes, dyed with different colors, and printed with the commercial printer and thus has promising applications in high-safety interior decoration of houses.

  9. Improved fire resistant radio frequency anechoic materials

    NASA Technical Reports Server (NTRS)

    Robinson, D. A.

    1969-01-01

    Protective, flameproof foam covering improves the resistance to fire and surface contamination of low-cost radio frequency absorbing and shielding anechoic materials. This promotes safety of operating personnel and equipment being tested in an otherwise combustible anechoic chamber.

  10. Hybrid TE panel test results

    NASA Technical Reports Server (NTRS)

    Bifano, W. J.

    1972-01-01

    Test results are presented for a nine couple (3 x 3 array) thermoelectric panel of hybrid thermocouples. In the hybrid couple, a hollow cylinder of p-type Si-Ge is used to encapsulate a segmented PbTe/Si-Ge n-leg. The hybrid couple is predicted to offer a 10- to 15-percent improvement in performance relative to all Si-Ge couples. The efficiency, output power, and internal resistance of the panel as well as the resistances of the individual hybrid couples are presented as a function of test time covering a period of more than 2600 hours. Initial test results indicated hybrid couple performance consistent with design predictions. Extraneous resistance ranged from 20 to 25% of the hybrid couple thermoelectric resistance.

  11. FR/HR Sewing Thread

    DTIC Science & Technology

    2015-09-01

    position unless so designated by other authorized documents. Citation of trade names in this report does not constitute an official endorsement or...project to design and develop a Fire Resistant (FR) and Heat Resistant (HR) sewing thread. The main goal of the project is to produce sewing threads made...addresses the design , development and testing of various Fire Resistant (FR)/Heat Resistant (HR) sewing threads for US Army applications. Such a sewing

  12. Investigation of Fire-Vulnerability-Reduction Effectiveness of Fire-Resistant Diesel Fuel in Armored Vehicular Fuel Tanks

    DTIC Science & Technology

    1980-09-30

    Aberdeen Proving Ground, Maryland, September 1976. 2. Weatherford, W.D., Jr., Fodor, G.E., Naegeli , D.W., Owens, E.C., Wright, B.R., and Schaekel, F.W...Weatherford, W.I)., Jr., Fodor, G.E., Naegeli , D.W., Owens, E.C., Wright, B.R., and Schaekel, F.W., "Development of Army Fire-Resistant Diesel Fuel," Interim

  13. Experimental Study on the Fire Performance of Tubular Steel Columns with Membrane Protections for Prefabricated and Modular Steel Construction

    PubMed Central

    Zhang, Xin; Peng, Lei; Ni, Zhao-peng; Ni, Tian-xiao; Huang, Yi-liang; Zhou, Yang

    2018-01-01

    Experimental research was conducted to study the fire resistance of steel tubular columns used in prefabricated and modular construction. In order to achieve high-efficient prefabrication and fast on-site installation, membrane protections using board products and thermal insulation blankets are adopted as the favorable protection method. Three protected tubular columns were tested in a full-scale column furnace with axial load applied. The study variables were different membranes, including fiber reinforced calcium silicate (FRCS) boards, rock wool and aluminum silica (Fiberfrax) insulations. The results suggest that one layer of 12 mm FRCS board with rock wool insulation has insufficient fire protection. However, steel columns protected with two layers of 12 mm FRCS boards with insulation appeared to have good fire resistances and could achieve a fire resistance rating as high as 2.5~3.0 h. PMID:29547574

  14. Study of coatings for improved fire and decay resistance of mine timbers

    NASA Technical Reports Server (NTRS)

    Baum, B.

    1977-01-01

    The purpose of this program was to find a fire- and rot-retardant polymer/fungicide reaction product for coating mine timbers. Fire-retardant polymers were screened as films and coatings on fir wood. Curable polyimide appeared to be flame retardant and evolved a minimum of fumes when exposed to a flame. Several organic and metal, low toxicity, fungicides were reacted with the polyimide in-situ on the wood. These coated samples were screened for fungus resistance. All formulations rated well - even the polyimide film without additives was fungicidal. The fir wood control itself resisted internal damage during the ten weeks of fungus exposure. A more severe test for fungus resistance will be required.

  15. Advanced fire-resistant forms of activated carbon and methods of adsorbing and separating gases using same

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xiong, Yongliang; Wang, Yifeng

    Advanced, fire-resistant activated carbon compositions useful in adsorbing gases; and having vastly improved fire resistance are provided, and methods for synthesizing the compositions are also provided. The advanced compositions have high gas adsorption capacities and rapid adsorption kinetics (comparable to commercially-available activated carbon), without having any intrinsic fire hazard. They also have superior performance to Mordenites in both adsorption capacities and kinetics. In addition, the advanced compositions do not pose the fibrous inhalation hazard that exists with use of Mordenites. The fire-resistant compositions combine activated carbon mixed with one or more hydrated and/or carbonate-containing minerals that release H.sub.2O and/or CO.sub.2more » when heated. This effect raises the spontaneous ignition temperature to over 500.degree. C. in most examples, and over 800.degree. C. in some examples. Also provided are methods for removing and/or separating target gases, such as Krypton or Argon, from a gas stream by using such advanced activated carbons.« less

  16. Where there's smoking, there's fire: the effects of smoking policies on the incidence of fires in the USA.

    PubMed

    Markowitz, Sara

    2014-11-01

    Fires and burns are among the leading causes of unintentional death in the USA. Most of these deaths occur in residences, and cigarettes are a primary cause. In this paper, I explore the relationship between smoking, cigarette policies, and fires. As smoking rates decline, there are fewer opportunities for fires; however, the magnitude of any reduction is in question. Using a state-level panel, I find that increases in cigarette prices are associated with fewer residential fires and deaths. However, laws regulating indoor smoking are associated with more fires; in particular, restaurant and bar smoking bans are associated with an increase in fires at eating and drinking establishments. This increase is important given the growing popularity of smoking bans in the USA and around the world. As workplaces, schools, and businesses ban smoking and remove ashtrays, smokers who continue to smoke are left without safe options for disposal of cigarettes, leading to more opportunities for fires to start. Copyright © 2013 John Wiley & Sons, Ltd.

  17. Fire resistant nuclear fuel cask

    DOEpatents

    Heckman, Richard C.; Moss, Marvin

    1979-01-01

    The disclosure is directed to a fire resistant nuclear fuel cask employing reversibly thermally expansible bands between adjacent cooling fins such that normal outward flow of heat is not interfered with, but abnormal inward flow of heat is impeded or blocked.

  18. Substance Testing in the Fire Service: Making Public Safety a Matter of National Policy

    DTIC Science & Technology

    2014-03-01

    25). Leshner (1999) submits that virtually every addictive substance—be it cocaine, marijuana , methamphetamine, heroin, or nicotine— appears to...safety sensitive. The DOT test panel tests for five classifications of drugs: amphetamines, cocaine, marijuana , opiates, and phencyclidine. When the...methods are laws, political/socio-cultural, pricing of services, and individual fire departments. Marijuana has been legalized in a number of states

  19. Effects of fiber processing on properties of fiber and fiberboard made from lodgepole pine treetops

    Treesearch

    John F. Hunt; Aziz Ahmed; Katherine Friedrich

    2008-01-01

    As a part of the National Fire Plan, the USDA Forest Service is conducting research to reduce the severity of forest fires through effective utilization of low-or no-value logging residues and forest thinnings. This report explores the effect of processing on the physical properties of the fibrous material and flat fiberboard panels made from small-diameter lodgepole...

  20. FAA Rotorcraft Research, Engineering, and Development Bibliography, 1962-1988. Supplement

    DTIC Science & Technology

    1989-03-01

    fires, the aircraft engine was the major fire origin for twin- and single- engine air - craft. Only in single- engine aircraft was the instrument panel a...Certification Issues. The topics of Operational Requirements, Procedures, Air - worthiness and Engineering Capabilities are discussed. Volume II presents the...Issues. The topics of Operational Requirements, Procedures, Air - worthiness and Engineering Capabilities are discussed. Volume II presents the operator

  1. Properties of Wheat-Straw Boards with Frw Based on Interface Treatment

    NASA Astrophysics Data System (ADS)

    Zhu, X. D.; Wang, F. H.; Liu, Y.

    This paper explored the effect of MDI, UF and FRW content on the mechanical and fire retardant property of straw based panels with surface alkali liquor processing. In order to manufacture the straw based panel with high quality, low toxic and fire retardant, the interface of wheat-straw was treated with alkaline liquid, and the orthogonal test was carried out to optimize the technical parameters. The conductivity and diffusion coefficient K of the straw material after alkaline liquid treatment increased obviously. This indicated that alkaline liquid treatment improved the surface wet ability of straw, which is helpful for the infiltration of resin. The results of orthogonal test showed that the optimized treating condition was alkaline liquid concentration as 0.4-0.8%, alkaline dosage as 1:2.5-1:4.5, alkalinetreated time as 12h-48 h.The physical and mechanical properties of wheat-straw boards after treated increased remarkably and it could satisfy the national standard. The improvement of the straw surface wet ability is helpful to the forming of chemical bond. Whereas the variance analysis of the fire retardant property of straw based panel showed that TTI, pkHRR and peak value appearance time were not affected by the MDI, UF and FRW content significantly. The results of orthogonal test showed that the optimized processing condition was MDI content as 3%, UF resin content as 6% and the FRW content as 10%.

  2. Multisensor Fire Observations

    NASA Technical Reports Server (NTRS)

    Boquist, C.

    2004-01-01

    This DVD includes animations of multisensor fire observations from the following satellite sources: Landsat, GOES, TOMS, Terra, QuikSCAT, and TRMM. Some of the animations are included in multiple versions of a short video presentation on the DVD which focuses on the Hayman, Rodeo-Chediski, and Biscuit fires during the 2002 North American fire season. In one version of the presentation, MODIS, TRMM, GOES, and QuikSCAT data are incorporated into the animations of these wildfires. These data products provided rain, wind, cloud, and aerosol data on the fires, and monitored the smoke and destruction created by them. Another presentation on the DVD consists of a panel discussion, in which experts from academia, NASA, and the U.S. Forest Service answer questions on the role of NASA in fighting forest fires, the role of the Terra satellite and its instruments, including the Moderate Resolution Imaging Spectroradiometer (MODIS), in fire fighting decision making, and the role of fire in the Earth's climate. The third section of the DVD features several animations of fires over the years 2001-2003, including animations of global and North American fires, and specific fires from 2003 in California, Washington, Montana, and Arizona.

  3. Experiments of the selection of a method evaluating the fire resistance of some materials based on macromolecular compounds

    NASA Technical Reports Server (NTRS)

    Stoica, Steln; Sebe, Mircea Octavian

    1987-01-01

    A comparative experimental study on the application of various tests for the evaluation of the fire-resistant properties of plastic materials is presented. On the basis of the results obtained conclusions are drawn on the advantages and disadvantages of the methods used, and a preferred test method is picked, i.e., the introduction of fire retardant materials into the polymers.

  4. Initial Burn Pan (JMTF) Testing Results

    DTIC Science & Technology

    2016-03-01

    of Testing and Materials (ASTM) standard for fire - resistant boom. It had not been used for over 15 years and was almost completely destroyed when...Environment Canada had produced operational guides, provided standards for fire - resistant booms and igniting techniques needed to perform offshore burns...are currently in the smoke zone; and the heat from the fire could be felt from that area. While no one was injured, some miscommunication at the

  5. Indications of vigor loss after fire in Caribbean pine (Pinus caribaea) from electrical resistance measurements

    Treesearch

    T.E. Paysen; A.L. Koonce; E. Taylor; M.O. Rodriquez

    2006-01-01

    In May 1993, electrical resistance measurements were performed on trees in burned and unburned stands of Caribbean pine (Pinus caribaea Mor.) in north-eastern Nicaragua to determine whether tree vigor was affected by fire. An Osmose model OZ-67 Shigometer with digital readout was used to collect the sample electrical resistance data. Computer-...

  6. Modal analysis and dynamic stresses for acoustically excited shuttle insulation tiles

    NASA Technical Reports Server (NTRS)

    Ojalvo, I. U.; Ogilvie, P. L.

    1975-01-01

    Improvements and extensions to the RESIST computer program developed for determining the normalized modal stress response of shuttle insulation tiles are described. The new version of RESIST can accommodate primary structure panels with closed-cell stringers, in addition to the capability for treating open-cell stringers. In addition, the present version of RESIST numerically solves vibration problems several times faster than its predecessor. A new digital computer program, titled ARREST (Acoustic Response of Reusable Shuttle Tiles) is also described. Starting with modal information contained on output tapes from RESIST computer runs, ARREST determines RMS stresses, deflections and accelerations of shuttle panels with reusable surface insulation tiles. Both programs are applicable to stringer stiffened structural panels with or without reusable surface insulation titles.

  7. 30 CFR 75.1107-13 - Approval of other fire suppression devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-13 Approval of... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approval of other fire suppression devices. 75...

  8. 14 CFR 25.1731 - Powerplant and APU fire detector system: EWIS.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Powerplant and APU fire detector system... Systems (EWIS) § 25.1731 Powerplant and APU fire detector system: EWIS. (a) EWIS that are part of each fire or overheat detector system in a fire zone must be fire-resistant. (b) No EWIS component of any...

  9. 14 CFR 25.1731 - Powerplant and APU fire detector system: EWIS.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Powerplant and APU fire detector system... Systems (EWIS) § 25.1731 Powerplant and APU fire detector system: EWIS. (a) EWIS that are part of each fire or overheat detector system in a fire zone must be fire-resistant. (b) No EWIS component of any...

  10. 14 CFR 25.1731 - Powerplant and APU fire detector system: EWIS.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Powerplant and APU fire detector system... Systems (EWIS) § 25.1731 Powerplant and APU fire detector system: EWIS. (a) EWIS that are part of each fire or overheat detector system in a fire zone must be fire-resistant. (b) No EWIS component of any...

  11. 14 CFR 25.1731 - Powerplant and APU fire detector system: EWIS.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Powerplant and APU fire detector system... Systems (EWIS) § 25.1731 Powerplant and APU fire detector system: EWIS. (a) EWIS that are part of each fire or overheat detector system in a fire zone must be fire-resistant. (b) No EWIS component of any...

  12. 14 CFR 25.1731 - Powerplant and APU fire detector system: EWIS.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Powerplant and APU fire detector system... Systems (EWIS) § 25.1731 Powerplant and APU fire detector system: EWIS. (a) EWIS that are part of each fire or overheat detector system in a fire zone must be fire-resistant. (b) No EWIS component of any...

  13. Evaluation of a 15-inch widescreen OLED with sunlight-readable resistive touch panel

    NASA Astrophysics Data System (ADS)

    Hufnagel, Bruce D.; Tchon, Joseph L.; Bahadur, Birendra

    2012-06-01

    A commercially available 15-inch active-matrix organic light-emitting diode (AMOLED) television was modified to include a sunlight-readable resistive touch panel for technical evaluation with regard to a variety of rugged military and aerospace applications. By removing the circular polarizer (CP) from the AMOLED and relying on the touch panel's CP, the authors were able to minimize change in display luminance while adding touch capability and reducing reflectance.

  14. Fire blight resistance in wild accessions of Malus sieversii

    USDA-ARS?s Scientific Manuscript database

    Fire blight (Erwinia amylovora) is a devastating bacterial disease in apple that results in severe economic losses. Epidemics are becoming more common as susceptible cultivars and rootstocks are being planted, and control is becoming more difficult as antibiotic-resistant strains develop. Resistan...

  15. Economic analysis of electric heating based on critical electricity price

    NASA Astrophysics Data System (ADS)

    Xie, Feng; Sun, Zhijie; Zhou, Xinnan; Fu, Chengran; Yang, Jie

    2018-06-01

    The State Grid Corporation of China proposes an alternative energy strategy, which will make electric heating an important task in the field of residential electricity consumption. This article takes this as the background, has made the detailed introduction to the inhabitant electric heating technology, and take the Zhangjiakou electric panels heating technology as an example, from the expense angle, has carried on the analysis to the electric panels heating economy. In the field of residential heating, electric panels operating costs less than gas boilers. After customers implying energy-saving behavior, electric panels operating cost is even lower than coal-fired boilers. The critical price is higher than the execution price, which indicates that the economic performance of the electric panels is significantly higher than that of the coal boiler.

  16. Resistance to wildfire and early regeneration in natural broadleaved forest and pine plantation

    NASA Astrophysics Data System (ADS)

    Proença, Vânia; Pereira, Henrique M.; Vicente, Luís

    2010-11-01

    The response of an ecosystem to disturbance reflects its stability, which is determined by two components: resistance and resilience. We addressed both components in a study of early post-fire response of natural broadleaved forest ( Quercus robur, Ilex aquifolium) and pine plantation ( Pinus pinaster, Pinus sylvestris) to a wildfire that burned over 6000 ha in NW Portugal. Fire resistance was assessed from fire severity, tree mortality and sapling persistence. Understory fire resistance was similar between forests: fire severity at the surface level was moderate to low, and sapling persistence was low. At the canopy level, fire severity was generally low in broadleaved forest but heterogeneous in pine forest, and mean tree mortality was significantly higher in pine forest. Forest resilience was assessed by the comparison of the understory composition, species diversity and seedling abundance in unburned and burned plots in each forest type. Unburned broadleaved communities were dominated by perennial herbs (e.g., Arrhenatherum elatius) and woody species (e.g., Hedera hibernica, Erica arborea), all able to regenerate vegetatively. Unburned pine communities presented a higher abundance of shrubs, and most dominant species relied on post-fire seeding, with some species also being able to regenerate vegetatively (e.g., Ulex minor, Daboecia cantabrica). There were no differences in diversity measures in broadleaved forest, but burned communities in pine forest shared less species and were less rich and diverse than unburned communities. Seedling abundance was similar in burned and unburned plots in both forests. The slower reestablishment of understory pine communities is probably explained by the slower recovery rate of dominant species. These findings are ecologically relevant: the higher resistance and resilience of native broadleaved forest implies a higher stability in the maintenance of forest processes and the delivery of ecosystem services.

  17. 46 CFR 78.45-1 - When required.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... the following plans: (1) General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means...

  18. 46 CFR 78.45-1 - When required.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... the following plans: (1) General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means...

  19. 46 CFR 78.45-1 - When required.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... the following plans: (1) General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means...

  20. 46 CFR 78.45-1 - When required.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... the following plans: (1) General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means...

  1. 46 CFR 78.45-1 - When required.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... the following plans: (1) General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means...

  2. Testing and Selection of Fire-Resistant Materials for Spacecraft Use

    NASA Technical Reports Server (NTRS)

    Friedman, Robert; Jackson, Brian; Olson, Sandra

    2000-01-01

    Spacecraft fire-safety strategy emphasizes prevention, mostly through the selection of onboard items classified accord- ing to their fire resistance. The principal NASA acceptance tests described in this paper assess the flammability of materials and components under "worst-case" normal-gravity conditions of upward flame spread in controlled-oxygen atmospheres. Tests conducted on the ground, however, cannot duplicate the unique fire characteristics in the nonbuoyant low-gravity environment of orbiting spacecraft. Research shows that flammability an fire-spread rates in low gravity are sensitive to forced convection (ventilation flows) and atmospheric-oxygen concentration. These research results are helping to define new material-screening test methods that will better evaluate material performance in spacecraft.

  3. Art Concepts - Apollo VIII

    NASA Image and Video Library

    1968-12-02

    S68-51306 (December 1968) --- North American Rockwell artist's concept illustrating a phase of the scheduled Apollo 8 lunar orbit mission. Here, the Apollo 8 spacecraft lunar module adapter (SLA) panels, which have supported the Command and Service Modules, are jettisoned. This is done by astronauts firing the service module reaction control engines. A signal simultaneously deploys and jettisons the panels, separating the spacecraft from the SLA and deploying the high gain (deep space) antenna.

  4. Chemically amplified i-line positive resist for next-generation flat panel display

    NASA Astrophysics Data System (ADS)

    Lee, Hsing-Chieh; Lu, Ying-Hao; Huang, Shin-Yih; Lan, Wei-Jen; Hanabata, Makoto

    2017-03-01

    Traditional diazonaphthoquinone (DNQ) positive photoresists are widely used for TFT-LCD array process. Current LTPS technology has more than 600ppi resolution is required for small or middle-sized TFT liquid crystal display panels. One of the ways to enhance resolution is to apply i-line single exposure system instead of traditional g/h/ibroadband exposure system. We have been developing i-line chemically amplified photoresist ECA 200 series for the next generation flat panel display (FPD). ECA 200 consists of three components: a phenol resin, a photo acid generator and dissolution enhancer. We applied two different types of dissolution enhancers with two different kinds of protected groups to our resist materials. As a result, we achieved higher sensitivity, higher resolution, less footing of the resist profile and reduced standing wave effect compared with traditional DNQ photoresists. In addition, we have found further property of photoresist that does not need post exposure bake (PEB) process. This resist has a great advantage at most of current panel plants without PEB process.

  5. Rootstock-regulated gene expression patterns associated with fire blight resistance in apple

    USDA-ARS?s Scientific Manuscript database

    Background: Desirable apple varieties are clonally propagated by grafting vegetative scions onto rootstocks. Rootstocks influence many phenotypic traits of the scion, including resistance to pathogens such as Erwinia amylovora, which causes fire blight, the most serious bacterial disease of apple....

  6. Design and Test Requirements for Space Flight Pressurized Systems

    DTIC Science & Technology

    2014-11-26

    5.7.2 Fire Resistant Fluids ......................................................................................... 24 5.7.3 Accumulators...5.1.7 Threaded Parts [5.1.7-1] All threaded parts in components shall be securely locked to resist uncoupling forces by acceptable safe design...event of force balance on both inlet ports may occur, thus causing the shutoff valve to restrict flow from the outlet port. 5.7.2 Fire Resistant

  7. 46 CFR 97.36-1 - When required.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... the vessel the following plans: (a) General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means...

  8. 46 CFR 97.36-1 - When required.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... the vessel the following plans: (a) General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means...

  9. 46 CFR 97.36-1 - When required.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... the vessel the following plans: (a) General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means...

  10. Competitive effects of fire-resistant saplings on their fire-sensitive neighbors are greater than the reverse

    Treesearch

    J. Stephen Brewer

    2015-01-01

    Although repeated fires are generally thought to reduce competition, direct tests of this hypothesis are rare. Furthermore, recent theory predicts that fires can increase competitive effects of fireresistant species on fire-sensitive species and thus create stable assemblages dominated by the former. In this study, I quantified competition between saplings of fire-...

  11. Progression and Behavior of the Canoe Fire in Coast Redwood

    Treesearch

    Hugh Scanlon

    2007-01-01

    Lightning caused fires occur in coast redwood forests, but large fires have been rare since the 1930s. Coast redwood (Sequoia sempervirens) is considered fire resistant. In 2003, the Canoe Fire, a lightning fire started in an old-growth redwood stand in Humboldt Redwoods State Park, burned 5,554 hectares (13,774 acres) before it was contained. Fuel...

  12. Fire regimes of remnant pitch pine communities in the Ridge and Valley Region of central Pennsylvania, USA. Forests

    Treesearch

    Joseph Marschall; Michael Stambaugh; Benjamin Jones; Richard Guyette; Patrick Brose; Daniel C. Dey

    2016-01-01

    Many fire-adapted ecosystems in the northeastern U.S. are converting to fire-intolerant vegetation communities due to fire suppression in the 20th century. Prescribed fire and other vegetation management activities that increase resilience and resistance to global changes are increasingly being implemented, particularly on public lands. For many fire-dependent...

  13. 46 CFR 132.130 - Fire stations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... discharge both solid stream and water spray. (h) Each pipe and fire hydrant must be placed so that the fire... or other suitable corrosion-resistant material and comply with NFPA 1963. (k) Each fire hydrant must... 46 Shipping 4 2011-10-01 2011-10-01 false Fire stations. 132.130 Section 132.130 Shipping COAST...

  14. Pre-fire grazing by cattle increases postfire resistance to exotic annual grass (Bromus tectorum) invasion and dominance for decades

    USDA-ARS?s Scientific Manuscript database

    1. Fire, herbivory and their interaction influence plant community dynamics. However, little is known about the influence of pre-fire herbivory on post-fire plant community response, particularly long-term resilience to post-fire exotic plant invasion in areas that historically experienced limited ...

  15. The Fire Resistance Performance of Recycled Aggregate Concrete Columns with Different Concrete Compressive Strengths

    PubMed Central

    Dong, Hongying; Cao, Wanlin; Bian, Jianhui; Zhang, Jianwei

    2014-01-01

    In order to ascertain the fire resistance performance of recycled aggregate concrete (RAC) components with different concrete compressive strengths, four full-scaled concrete columns were designed and tested under high temperature. Two of the four specimens were constructed by normal concrete with compressive strength ratings of C20 and C30, respectively, while the others were made from recycled coarse aggregate (RCA) concrete of C30 and C40, respectively. Identical constant axial forces were applied to specimens while being subjected to simulated building fire conditions in a laboratory furnace. Several parameters from the experimental results were comparatively analyzed, including the temperature change, vertical displacement, lateral deflection, fire endurance, and failure characteristics of specimens. The temperature field of specimens was simulated with ABAQUS Software (ABAQUS Inc., Provindence, RI, USA) and the results agreed quite well with those from the experiments. Results show that the rate of heat transfer from the surface to the interior of the column increases with the increase of the concrete’s compressive strength for both RAC columns and normal concrete columns. Under the same initial axial force ratio, for columns with the same cross section, those with lower concrete compressive strengths demonstrate better fire resistance performance. The fire resistance performance of RAC columns is better than that of normal concrete columns, with the same concrete compressive strength. PMID:28788279

  16. The Fire Resistance Performance of Recycled Aggregate Concrete Columns with Different Concrete Compressive Strengths.

    PubMed

    Dong, Hongying; Cao, Wanlin; Bian, Jianhui; Zhang, Jianwei

    2014-12-08

    In order to ascertain the fire resistance performance of recycled aggregate concrete (RAC) components with different concrete compressive strengths, four full-scaled concrete columns were designed and tested under high temperature. Two of the four specimens were constructed by normal concrete with compressive strength ratings of C20 and C30, respectively, while the others were made from recycled coarse aggregate (RCA) concrete of C30 and C40, respectively. Identical constant axial forces were applied to specimens while being subjected to simulated building fire conditions in a laboratory furnace. Several parameters from the experimental results were comparatively analyzed, including the temperature change, vertical displacement, lateral deflection, fire endurance, and failure characteristics of specimens. The temperature field of specimens was simulated with ABAQUS Software (ABAQUS Inc., Provindence, RI, USA) and the results agreed quite well with those from the experiments. Results show that the rate of heat transfer from the surface to the interior of the column increases with the increase of the concrete's compressive strength for both RAC columns and normal concrete columns. Under the same initial axial force ratio, for columns with the same cross section, those with lower concrete compressive strengths demonstrate better fire resistance performance. The fire resistance performance of RAC columns is better than that of normal concrete columns, with the same concrete compressive strength.

  17. The analysis of factors of management of safety of critical information infrastructure with use of dynamic models

    NASA Astrophysics Data System (ADS)

    Trostyansky, S. N.; Kalach, A. V.; Lavlinsky, V. V.; Lankin, O. V.

    2018-03-01

    Based on the analysis of the dynamic model of panel data by region, including fire statistics for surveillance sites and statistics of a set of regional socio-economic indicators, as well as the time of rapid response of the state fire service to fires, the probability of fires in the surveillance sites and the risk of human death in The result of such fires from the values of the corresponding indicators for the previous year, a set of regional social-economics factors, as well as regional indicators time rapid response of the state fire service in the fire. The results obtained are consistent with the results of the application to the fire risks of the model of a rational offender. Estimation of the economic equivalent of human life from data on surveillance objects for Russia, calculated on the basis of the analysis of the presented dynamic model of fire risks, correctly agrees with the known literary data. The results obtained on the basis of the econometric approach to fire risks allow us to forecast fire risks at the supervisory sites in the regions of Russia and to develop management solutions to minimize such risks.

  18. Asthma - what to ask the doctor - adult

    MedlinePlus

    ... I have a fire in my fireplace or wood-burning stove? What sort of changes do I ... 42. National Asthma Education and Prevention Program Expert Panel Report 3: Guidelines for the Diagnosis and Management ...

  19. Assessing post-fire Douglas-fir mortality and Douglas-fir beetle attacks in the northern Rocky Mountains

    Treesearch

    Sharon Hood; Barbara Bentz; Ken Gibson; Kevin Ryan; Gregg DeNitto

    2007-01-01

    Douglas-fir has life history traits that greatly enhance resistance to injury from fire, thereby increasing post-fire survival rates. Tools for predicting the probability of tree mortality following fire are important components of both pre-fire planning and post-fire management efforts. Using data from mixed-severity wildfire in Montana and Wyoming, Hood and Bentz (...

  20. 46 CFR 27.301 - What are the requirements for fire pumps, fire mains, and fire hoses on towing vessels?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... the requirements for fire pumps, fire mains, and fire hoses on towing vessels? By April 29, 2005, you... from both branches of the fitting if the highest hydrant has a Siamese fitting, at a pitot-tube... of corrosion-resistant material capable of providing a solid stream and a spray pattern. (f) You must...

  1. 30 CFR 35.20 - Autogenous-ignition temperature test.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., EVALUATION, AND APPROVAL OF MINING PRODUCTS FIRE-RESISTANT HYDRAULIC FLUIDS Test Requirements § 35.20... (alundum or equivalent) cylinder 5 inches in internal diameter and 5 inches in height; a transite-ring top... is obtained. (d) Appraisal of test. A fluid shall be considered fire-resistant, according to the test...

  2. 30 CFR 35.20 - Autogenous-ignition temperature test.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., EVALUATION, AND APPROVAL OF MINING PRODUCTS FIRE-RESISTANT HYDRAULIC FLUIDS Test Requirements § 35.20... (alundum or equivalent) cylinder 5 inches in internal diameter and 5 inches in height; a transite-ring top... is obtained. (d) Appraisal of test. A fluid shall be considered fire-resistant, according to the test...

  3. 30 CFR 35.20 - Autogenous-ignition temperature test.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., EVALUATION, AND APPROVAL OF MINING PRODUCTS FIRE-RESISTANT HYDRAULIC FLUIDS Test Requirements § 35.20... (alundum or equivalent) cylinder 5 inches in internal diameter and 5 inches in height; a transite-ring top... is obtained. (d) Appraisal of test. A fluid shall be considered fire-resistant, according to the test...

  4. 30 CFR 35.20 - Autogenous-ignition temperature test.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., EVALUATION, AND APPROVAL OF MINING PRODUCTS FIRE-RESISTANT HYDRAULIC FLUIDS Test Requirements § 35.20... (alundum or equivalent) cylinder 5 inches in internal diameter and 5 inches in height; a transite-ring top... is obtained. (d) Appraisal of test. A fluid shall be considered fire-resistant, according to the test...

  5. 46 CFR 164.006-4 - Inspection and testing.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... attachments shall be incorporated in the samples. Each sample shall be heated in a furnace whose temperature... minutes—60 percent light transmission. 60 minutes—50 percent light transmission. (c) Fire resistance and integrity tests. (1) A sample of each thickness submitted shall be tested for fire resistance and integrity...

  6. 46 CFR 164.006-4 - Inspection and testing.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... attachments shall be incorporated in the samples. Each sample shall be heated in a furnace whose temperature... minutes—60 percent light transmission. 60 minutes—50 percent light transmission. (c) Fire resistance and integrity tests. (1) A sample of each thickness submitted shall be tested for fire resistance and integrity...

  7. 46 CFR 164.006-4 - Inspection and testing.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... attachments shall be incorporated in the samples. Each sample shall be heated in a furnace whose temperature... minutes—60 percent light transmission. 60 minutes—50 percent light transmission. (c) Fire resistance and integrity tests. (1) A sample of each thickness submitted shall be tested for fire resistance and integrity...

  8. 46 CFR 164.006-4 - Inspection and testing.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... attachments shall be incorporated in the samples. Each sample shall be heated in a furnace whose temperature... minutes—60 percent light transmission. 60 minutes—50 percent light transmission. (c) Fire resistance and integrity tests. (1) A sample of each thickness submitted shall be tested for fire resistance and integrity...

  9. 76 FR 32843 - Defense Federal Acquisition Regulation Supplement; Fire-Resistant Fiber for Production of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-06

    ... DEPARTMENT OF DEFENSE Defense Acquisition Regulations System 48 CFR Part 225 RIN 0750-AH22 Defense Federal Acquisition Regulation Supplement; Fire-Resistant Fiber for Production of Military Uniforms (DFARS Case 2011-D021) AGENCY: Defense Acquisition Regulations System, Department of Defense (DoD). ACTION...

  10. 46 CFR 105.35-15 - Fire hose.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... bronze or equivalent metal. (e) All fittings on fire hose shall be of brass, copper, or other suitable corrosion resistant metal. (f) A length of fire hose shall be attached to each fire hydrant at all times... 46 Shipping 4 2010-10-01 2010-10-01 false Fire hose. 105.35-15 Section 105.35-15 Shipping COAST...

  11. Reintroducing fire in regenerated dry forests following stand-replacing wildfire.

    Treesearch

    David W. Peterson; Paul F. Hessburg; Brion Salter; Kevin M. James; Matthew C. Dahlgreen; John A. Barnes

    2007-01-01

    Prescribed fire use may be effective for increasing fire resilience in young coniferous forests by reducing surface fuels, modifying overstory stand structure, and promoting development of large trees of fire resistant species. Questions remain, however, about when and how to reintroduce fire in regenerated forests, and to what end. We studied the effects of spring...

  12. Chapter 6: Fire damage of wood structures

    Treesearch

    B. Kukay; R.H. White; F. Woeste

    2012-01-01

    Depending on the severity, fire damage can compromise the structural integrity of wood structures such as buildings or residences. Fire damage of wood structures can incorporate several models that address (1) the type, cause, and spread of the fire, (2) the thermal gradients and fire-resistance ratings, and (3) the residual load capacity (Figure 6.1). If there is a...

  13. Apollo 13 post-flight Service Module tests to determine reason for explosion

    NASA Technical Reports Server (NTRS)

    1970-01-01

    Sequence photo from 16mm motion picture film of test at Langley Research Center which seeks to determine mechanism by which Apollo 13 panel was separated from Service Module. The test used a 1/2 scale model with a honeycomb sandwich panel and was conducted in a vacuum (41982); Second photograph in sequence of three of panel separation test at Langley Research Center (41983); Full-scale propogation test at the NASA Manned Spacecraft Center of fire inside the Apollo Service Module oxygen tank. The photograph from a motion picture sequence taken from outside the vessel shows failure of tank conduit with abrupt loss of oxygen pressure (41984); Third photograph in sequence of three showing panel separation test at Langley Research Center (41985).

  14. A review of fire effects on vegetation and soils in the Great Basin region: response and ecological site characteristics

    USGS Publications Warehouse

    Miller, Richard F.; Chambers, Jeanne C.; Pyke, David A.; Pierson, Fred B.; Williams, C. Jason

    2013-01-01

    This review synthesizes the state of knowledge on fire effects on vegetation and soils in semi-arid ecosystems in the Great Basin Region, including the central and northern Great Basin and Range, Columbia River Basin, and the Snake River Plain. We summarize available literature related to: (1) the effects of environmental gradients, ecological site, and vegetation characteristics on resilience to disturbance and resistance to invasive species; (2) the effects of fire on individual plant species and communities, biological soil crusts, seed banks, soil nutrients, and hydrology; and (3) the role of fire severity, fire versus fire surrogate treatments, and post-fire grazing in determining ecosystem response. From this, we identify knowledge gaps and present a framework for predicting plant successional trajectories following wild and prescribed fires and fire surrogate treatments. Possibly the three most important ecological site characteristics that influence a site’s resilience (ability of the ecological site to recover from disturbance) and resistance to invasive species are soil temperature/moisture regimes and the composition and structure of vegetation on the ecological site just prior to the disturbance event.

  15. Fire characteristics associated with firefighter injury on large federal wildland fires.

    PubMed

    Britton, Carla; Lynch, Charles F; Torner, James; Peek-Asa, Corinne

    2013-02-01

    Wildland fires present many injury hazards to firefighters. We estimate injury rates and identify fire-related factors associated with injury. Data from the National Interagency Fire Center from 2003 to 2007 provided the number of injuries in which the firefighter could not return to his or her job assignment, person-days worked, and fire characteristics (year, region, season, cause, fuel type, resistance to control, and structures destroyed). We assessed fire-level risk factors of having at least one reported injury using logistic regression. Negative binomial regression was used to examine incidence rate ratios associated with fire-level risk factors. Of 867 fires, 9.5% required the most complex management and 24.7% required the next-highest level of management. Fires most often occurred in the western United States (82.8%), during the summer (69.6%), caused by lightening (54.9%). Timber was the most frequent fuel source (40.2%). Peak incident management level, person-days of exposure, and the fire's resistance to control were significantly related to the odds of a fire having at least one reported injury. However, the most complex fires had a lower injury incidence rate than less complex fires. Although fire complexity and the number of firefighters were associated with the risk for at least one reported injury, the more experienced and specialized firefighting teams had lower injury incidence. Copyright © 2013 Elsevier Inc. All rights reserved.

  16. Rapid Identification of Pathogens from Positive Blood Cultures by Multiplex PCR using the FilmArray System

    PubMed Central

    Blaschke, Anne J.; Heyrend, Caroline; Byington, Carrie L.; Fisher, Mark A.; Barker, Elizabeth; Garrone, Nicholas F.; Thatcher, Stephanie A.; Pavia, Andrew T.; Barney, Trenda; Alger, Garrison D.; Daly, Judy A.; Ririe, Kirk M.; Ota, Irene; Poritz, Mark A.

    2012-01-01

    Sepsis is a leading cause of death. Rapid and accurate identification of pathogens and antimicrobial resistance directly from blood culture could improve patient outcomes. The FilmArray® (FA; Idaho Technology, Inc., Salt Lake City, UT) Blood Culture (BC) panel can identify > 25 pathogens and 4 antibiotic resistance genes from positive blood cultures in 1 hour. We compared a development version of the panel to conventional culture and susceptibility testing on 102 archived blood cultures from adults and children with bacteremia. Of 109 pathogens identified by culture, 95% were identified by FA. Among 111 prospectively collected blood cultures, the FA identified 84 of 92 pathogens (91%) covered by the panel. Among 25 Staphylococcus aureus and 21 Enterococcus species detected, FA identified all culture-proven MRSA and VRE. The FA BC panel is an accurate method for the rapid identification of pathogens and resistance genes from blood culture. PMID:22999332

  17. Procedure for contact electrical resistance measurements as developed for use at Sandia National Laboratories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Finch, J.L.

    1994-06-01

    Military Specifications call out general procedures and guidelines for conducting contact resistance measurements on chemical conversion coated panels. This paper deals with a test procedure developed at Sandia National Laboratories used to conduct contact electrical resistance on non-chromated conversion coated test panels. MIL-C-81706 {open_quotes}Chemical Conversion Materials For Coating Aluminum and Aluminum Alloys{close_quotes} was the reference specification used for guidance.

  18. Demonstration/Validation of Low Volatile Organic Compound (VOC) Chemical Agent Resistant Coating (CARC)

    DTIC Science & Technology

    2003-11-25

    alkyd resin enamel was 14 Figure 1 -- Test Panels Before Application of WD CARC at MCB Figure 2 -- Test Panels with WD CARC Applied at MCB...WD) Chemical Agent Resistant Coating (CARC) patented (#5,691,410) by the Army Research Laboratory (ARL) has undergone technology Demonstration...Resistant Coating (CARC) patented (#5,691,410) by the Army Research Laboratory (ARL) has undergone technology Demonstration/Validation (Dem/Val) testing

  19. 30 CFR 75.1107-8 - Fire suppression devices; extinguishant supply systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-8... liquid chemical to protect attended equipment shall: (1) Be maintained at a pressure consistent with the...

  20. 30 CFR 75.1107-8 - Fire suppression devices; extinguishant supply systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-8... liquid chemical to protect attended equipment shall: (1) Be maintained at a pressure consistent with the...

  1. Low-smoke, halogenfree ship-offshore/onshore cables with improved flame retardance and fire resistance

    NASA Astrophysics Data System (ADS)

    Pedersen, J. R.; Holte, T. A.; Johansen, E.

    Cables with improved fire resistance and flame retardance have been developed. They will continue to function at least 3 hours even at temperatures up to 1000 C and do not propagate fire when tested according to IEC 332 part 3 1982, category A. Made with halogenfree materials they give off no corrosive gases and very little visible smoke in cases of fire. Cables are made for power, signal and instrument installations in hospitals, high rise buildings, railroad cars, subways, on board ship, oil rigs and oil production platforms. The offshore cables are specially constructed to withstand the rugged climatic conditions in the North Sea area.

  2. NASA technical advances in aircraft occupant safety. [clear air turbulence detectors, fire resistant materials, and crashworthiness

    NASA Technical Reports Server (NTRS)

    Enders, J. H.

    1978-01-01

    NASA's aviation safety technology program examines specific safety problems associated with atmospheric hazards, crash-fire survival, control of aircraft on runways, human factors, terminal area operations hazards, and accident factors simulation. While aircraft occupants are ultimately affected by any of these hazards, their well-being is immediately impacted by three specific events: unexpected turbulence encounters, fire and its effects, and crash impact. NASA research in the application of laser technology to the problem of clear air turbulence detection, the development of fire resistant materials for aircraft construction, and to the improvement of seats and restraint systems to reduce crash injuries are reviewed.

  3. 46 CFR 132.100 - General.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... equivalent fire-resistant material; and (2) Fitted with a commercial garden-hose nozzle of high-grade bronze..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS FIRE-PROTECTION EQUIPMENT Fire Main § 132... equipped with a fire main that complies with this subpart. (b) Each vessel of less than 100 gross tons and...

  4. Design of structures against fire. Civil engineering/buildings, architecture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anchor, R.D.; Malhotra, H.L.; Purkiss, J.A.

    1986-01-01

    The book covers structural design criteria, along with background theory on fire protection methods for structures from a variety of materials, including timber, steel, and concrete. Research on the behavior of structural materials in the presence of fire is highlighted, and the need for fire-resistant materials is addressed.

  5. 14 CFR 121.275 - Fire detectors.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Fire detectors. 121.275 Section 121.275..., FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.275 Fire detectors. Fire detectors must be made and installed in a manner that assures their ability to resist, without failure, all...

  6. 14 CFR 121.275 - Fire detectors.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Fire detectors. 121.275 Section 121.275..., FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.275 Fire detectors. Fire detectors must be made and installed in a manner that assures their ability to resist, without failure, all...

  7. 14 CFR 121.275 - Fire detectors.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Fire detectors. 121.275 Section 121.275..., FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.275 Fire detectors. Fire detectors must be made and installed in a manner that assures their ability to resist, without failure, all...

  8. 14 CFR 121.275 - Fire detectors.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Fire detectors. 121.275 Section 121.275..., FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.275 Fire detectors. Fire detectors must be made and installed in a manner that assures their ability to resist, without failure, all...

  9. 14 CFR 121.275 - Fire detectors.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Fire detectors. 121.275 Section 121.275..., FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.275 Fire detectors. Fire detectors must be made and installed in a manner that assures their ability to resist, without failure, all...

  10. FDA-CDC Antimicrobial Resistance Isolate Bank: a Publicly Available Resource To Support Research, Development, and Regulatory Requirements.

    PubMed

    Lutgring, Joseph D; Machado, María-José; Benahmed, Faiza H; Conville, Patricia; Shawar, Ribhi M; Patel, Jean; Brown, Allison C

    2018-02-01

    The FDA-CDC Antimicrobial Resistance Isolate Bank was created in July 2015 as a publicly available resource to combat antimicrobial resistance. It is a curated repository of bacterial isolates with an assortment of clinically important resistance mechanisms that have been phenotypically and genotypically characterized. In the first 2 years of operation, the bank offered 14 panels comprising 496 unique isolates and had filled 486 orders from 394 institutions throughout the United States. New panels are being added. Copyright © 2018 American Society for Microbiology.

  11. Nano-fibrillated cellulose-hydroxyapatite based composite foams with excellent fire resistance.

    PubMed

    Guo, Wenwen; Wang, Xin; Zhang, Ping; Liu, Jiajia; Song, Lei; Hu, Yuan

    2018-09-01

    Thermally insulating materials made from renewable resources are desirable for energy efficient buildings. Traditional petroleum-derived insulating materials such as rigid polyurethane foam and expanded polystyrene display poor flame retardancy and inorganic insulating materials such as silica aerogel are fragile. Herein, we reported a facile approach to prepare cellulose nanofiber (CNF)-hydroxyapatite (HAP) composite foam by a simple freeze-drying process. The resultant HAP-CNF composite foams showed a thermal conductivity in the range of 38.5-39.1 mW/(m K) and very low peak heat release rate (20.4 kW/m 2 ) and total heat release (1.21 MJ/m 2 ). Vertical burning tests also manifested excellent fire resistance and self-extinguishing behaviours. Considering the excellent fire resistance of this composite foam, it is of significance to fire safety solution for buildings insulating materials. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Termite Resistance of MDF Panels Treated with Various Boron Compounds

    PubMed Central

    Usta, Mustafa; Ustaomer, Derya; Kartal, Saip Nami; Ondaral, Sedat

    2009-01-01

    In this study, the effects of various boron compounds on the termite resistance of MDF panels were evaluated. Either borax (BX), boric acid (BA), zinc borate (ZB), or sodium perborate tetrahydrate (SPT) were added to urea-formaldehyde (UF) resin at target contents of 1%, 1.5%, 2% and 2.5% based on dry fiber weight. The panels were then manufactured using 12% urea-formaldehyde resin and 1% NH4Cl. MDF samples from the panels were tested against the subterranean termites, Coptotermes formosanus Shiraki. Laboratory termite resistance tests showed that all samples containing boron compounds had greater resistance against termite attack compared to untreated MDF samples. At the second and third weeks of exposure, nearly 100% termite mortalities were recorded in all boron compound treated samples. The highest termite mortalities were determined in the samples with either BA or BX. Also, it was found that SPT showed notable performance on the termite mortality. As chemical loadings increased, termite mortalities increased, and at the same time the weight losses of the samples decreased. PMID:19582229

  13. Smoke from Colorado Wildfires

    NASA Technical Reports Server (NTRS)

    2002-01-01

    The Hayman fire, situated about 65 kilometers southwest of Denver, Colorado, is the largest fire ever recorded in that state. The amount and distribution of smoke from the Hayman fire and from the Ponil Complex fires south of the New Mexico-Colorado border are portrayed in these views from the Multi-angle Imaging SpectroRadiometer (MISR). The images were captured on June 9, 2002, on the second day of the Hayman fire, when only about 13 percent of the total 137,000 acres eventually consumed had been scorched.

    The image at top-left was acquired by MISR's most oblique (70-degree) forward-viewing camera, and the view at bottom-left was captured by MISR's 26-degree forward-viewing camera. Both left-hand panels are 'false color' views, utilizing near-infrared, red, and blue spectral bands displayed as red, green and blue respectively. With this spectral combination, highly vegetated areas appear red. At top right is a map of aerosol optical depth. This map utilizes the capability of the oblique view angles to measure the abundance of particles in the atmosphere. Haze distributed across the eastern part of the state is indicated by a large number of green pixels, and areas where no retrieval occurred are shown in dark grey. The more oblique perspective utilized within the top panels enhances the appearance of smoke and reveals the haze. In the lower left-hand panel the view is closer to nadir (downward-looking). Here the smoke plumes appear more compact and the haze across eastern Colorado is not detected. The lower right-hand panel is a stereoscopically derived height field that echoes the compact shape of the smoke plumes in the near-nadir image. Results indicate that the smoke plumes reached altitudes of a few kilometers above the surface terrain, or about the same height as the small clouds that appear orange along the bottom edge to the left of center.

    Data used in these visualizations were generated as part of operational processing at the Atmospheric Sciences Data Center at NASA Langley Research Center. The images were acquired during Terra orbit 13170 and cover an area of about 400 kilometers x 565 kilometers. They utilize data from blocks 58 to 61 within World Reference System-2 path 32.

    MISR was built and is managed by NASA's Jet Propulsion Laboratory, Pasadena, CA, for NASA's Office of Earth Science, Washington, DC. The Terra satellite is managed by NASA's Goddard Space Flight Center, Greenbelt, MD. JPL is a division of the California Institute of Technology.

  14. 4. Historic American Buildings Survey, Theodore F. Dillon, Photographer, July, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. Historic American Buildings Survey, Theodore F. Dillon, Photographer, July, 1959 DETAIL OF CAST TERRA COTTA PANELS AND CORNICE. - Mutual Fire Insurance Company Building, Germantown Avenue & School House Lane, Philadelphia, Philadelphia County, PA

  15. 46 CFR 28.370 - Wiring methods and materials.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Boat or UL Marine Shipboard cable; or (iii) Meet 46 CFR part 111, subpart 111.60. (e) All metallic... enclosure such as a junction box, fixture enclosure, or panel enclosure. A fire retardant plastic enclosure...

  16. Fuel moisture influences on fire-altered carbon in masticated fuels: An experimental study

    Treesearch

    Nolan W. Brewer; Alistair M.S. Smith; Jeffery A. Hatten; Philip E. Higuera; Andrew T. Hudak; Roger D. Ottmar; Wade T. Tinkham

    2013-01-01

    Biomass burning is a significant contributor to atmospheric carbon emissions but may also provide an avenue in which fire-affected ecosystems can accumulate carbon over time, through the generation of highly resistant fire-altered carbon. Identifying how fuel moisture, and subsequent changes in the fire behavior, relates to the production of fire-altered carbon is...

  17. Effectiveness of fire-retardant treatments for shingles after 10 years of outdoor weathering

    Treesearch

    S. L. LeVan; C. A. Holmes

    Some building codes require wood shingles to be fire-retardant treated. Because exterior fire-retardant treatments are subjected to weathering, treatment durability and leach resistance are critical for insuring adequate fire protection. We examined the effectiveness of various fire-retardant treatments on wood after 0, 2, 5, and 10 years of outdoor exposure. We used a...

  18. Resistance of the boreal forest to high burn rates.

    PubMed

    Héon, Jessie; Arseneault, Dominique; Parisien, Marc-André

    2014-09-23

    Boreal ecosystems and their large carbon stocks are strongly shaped by extensive wildfires. Coupling climate projections with records of area burned during the last 3 decades across the North American boreal zone suggests that area burned will increase by 30-500% by the end of the 21st century, with a cascading effect on ecosystem dynamics and on the boreal carbon balance. Fire size and the frequency of large-fire years are both expected to increase. However, how fire size and time since previous fire will influence future burn rates is poorly understood, mostly because of incomplete records of past fire overlaps. Here, we reconstruct the length of overlapping fires along a 190-km-long transect during the last 200 y in one of the most fire-prone boreal regions of North America to document how fire size and time since previous fire will influence future fire recurrence. We provide direct field evidence that extreme burn rates can be sustained by a few occasional droughts triggering immense fires. However, we also show that the most fire-prone areas of the North American boreal forest are resistant to high burn rates because of overabundant young forest stands, thereby creating a fuel-mediated negative feedback on fire activity. These findings will help refine projections of fire effect on boreal ecosystems and their large carbon stocks.

  19. Resistance of the boreal forest to high burn rates

    PubMed Central

    Héon, Jessie; Arseneault, Dominique; Parisien, Marc-André

    2014-01-01

    Boreal ecosystems and their large carbon stocks are strongly shaped by extensive wildfires. Coupling climate projections with records of area burned during the last 3 decades across the North American boreal zone suggests that area burned will increase by 30–500% by the end of the 21st century, with a cascading effect on ecosystem dynamics and on the boreal carbon balance. Fire size and the frequency of large-fire years are both expected to increase. However, how fire size and time since previous fire will influence future burn rates is poorly understood, mostly because of incomplete records of past fire overlaps. Here, we reconstruct the length of overlapping fires along a 190-km-long transect during the last 200 y in one of the most fire-prone boreal regions of North America to document how fire size and time since previous fire will influence future fire recurrence. We provide direct field evidence that extreme burn rates can be sustained by a few occasional droughts triggering immense fires. However, we also show that the most fire-prone areas of the North American boreal forest are resistant to high burn rates because of overabundant young forest stands, thereby creating a fuel-mediated negative feedback on fire activity. These findings will help refine projections of fire effect on boreal ecosystems and their large carbon stocks. PMID:25201981

  20. Fire resistant aircraft seat program

    NASA Technical Reports Server (NTRS)

    Fewell, L. A.

    1979-01-01

    Foams, textiles, and thermoformable plastics were tested to determine which materials were fire retardant, and safe for aircraft passenger seats. Seat components investigated were the decorative fabric cover, slip covers, fire blocking layer, cushion reinforcement, and the cushioning layer.

  1. 30 CFR 75.1107-3 - Fire suppression devices; approved components; installation requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-3... agency approved by the Secretary. (b) Where used, pressure vessels shall conform with the requirements of...

  2. 30 CFR 75.1107-3 - Fire suppression devices; approved components; installation requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-3... agency approved by the Secretary. (b) Where used, pressure vessels shall conform with the requirements of...

  3. 30 CFR 75.1107-3 - Fire suppression devices; approved components; installation requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-3... agency approved by the Secretary. (b) Where used, pressure vessels shall conform with the requirements of...

  4. 30 CFR 75.1107-3 - Fire suppression devices; approved components; installation requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-3... agency approved by the Secretary. (b) Where used, pressure vessels shall conform with the requirements of...

  5. 30 CFR 75.1107-3 - Fire suppression devices; approved components; installation requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-3... agency approved by the Secretary. (b) Where used, pressure vessels shall conform with the requirements of...

  6. Analytical methods for determining fire resistance of timber members

    Treesearch

    Robert H. White

    2008-01-01

    The fire resistance ratings of wood members and assemblies, as of other materials, have traditionally been obtained by testing the assembly in a furnace in accordance with ASTM International (ASTM) Standard E119, International Organization for Standardization (ISO) Standard 834, and similar standards. These ratings are published in listings, such as Underwriters...

  7. Biological Efficacy of Permethrin Treatment on New U.S. Military Uniforms

    USDA-ARS?s Scientific Manuscript database

    The United States Army and United States Marine Corps (USMC) are fielding uniforms that incorporate fire resistant fibers into the uniform material. For the U.S. Army, the change in uniform composition to produce the Fire-Resistant Army Combat Uniform (FRACU) results in a uniform that does not reta...

  8. Development of a Fire-Resistant Anti-Sweat Submarine Hull Insulation Based on Fiber Glass Materials.

    DTIC Science & Technology

    1983-09-01

    CHART NATIONAL BUREAU OF STANDARDS-1963-A6w " ;’’ ..J’ d’ ,.,, -,,,.. ,.- -,. . 11111, , .. b,, I - - -.. .,. , .. . ..°.. III. . . ,Lm’ Johns ... Manville Research & Development Center DEVELOPMENT OF A FIRE-RESISTANT ANTI-SWEAT SUBMARINE HULL INSULATION BASED ON FIBER *" GLASS MATERIALS Oct icrb iz Ic

  9. Exterior building details of Building B, east façade: embedded wood ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Exterior building details of Building B, east façade: embedded wood beams and interrupted dentil course cornice resulting from the removal of the third floor tuberculosis ward, yard level paneled Dutch door, second level two a typical six-light wood casement windows over a single-panel wood door with four light exits to fire escape; westerly view - San Quentin State Prison, Building 22, Point San Quentin, San Quentin, Marin County, CA

  10. A Combined Hazard Index Fire Test Methodology for Aircraft Cabin Materials. Volume I.

    DTIC Science & Technology

    1982-04-01

    PROGRAM TEST PANEL NO. 1 ....... 52 5 SUMARY OF EXPERIMTAL CHAS/SATS DATA FOR CI PRGRAM TEST PANEL 2, 3 & 4...As indicated in Figure 2, the dose of each hazard building up in CHI zone 13 is approaching an "effective dose" limit which prevents occupant escape...per minute. During a test, flow into SATS was stopped when CO reached peak concentrations to prevent dilution thereafter at decreasing sample CO

  11. Evaluation of the AMEREX Model 775 Wheeled Extinguisher with Novec 1230

    DTIC Science & Technology

    2014-11-18

    simulate different fire scenarios. The nacelle sits atop a concave concrete pad that can collect a pool of jet fuel as part of the fire scenario...Up Used for Rear Engine Testing and Access Panel Testing. In This Photo, Fuel is Flowing through the Nacelle in Preparation for a Rear Engine Test...Figure 8. Fuel Cups Positioned At 5-ft Intervals from the Amerex Extinguisher (Background) (left); Firefighter Discharges the Extinguisher into/over the

  12. Afghan Ministry of Defense Headquarters: $154.7 Million Building Appears Well Built, but Has Several Construction Issues that Should Be Assessed

    DTIC Science & Technology

    2016-02-01

    complete breaks in the floors, walls, and ceilings that divide the building into discrete sections. The objectives of this inspection were to... ceiling panels, as well as fire suppression pumps, fire alarms, and communications lines. We found other deficiencies not identified by AFCEC that...structural components suspended from the ceiling or floor above, such as heating/cooling equipment, duct work, dropped ceilings , electrical fixtures

  13. Land uses, fire, and invasion: Exotic annual Bromus and human dimensions

    USGS Publications Warehouse

    Pyke, David A.; Chambers, Jeanne C.; Beck, Jeffrey L.; Brooks, Matthew L.; Mealor, Brian A.

    2016-01-01

    Human land uses are the primary cause of the introduction and spread of exotic annual Bromusspecies. Initial introductions were likely linked to contaminated seeds used by homesteading farmers in the late 1880s and early 1900s. Transportation routes aided their spread. Unrestricted livestock grazing from the 1800s through the mid-1900s reduced native plant competitors leaving large areas vulnerable to Bromus dominance. Ecosystems with cooler and moister soils tend to have greater potential to recover from disturbances (resilience) and to be more resistant to Bromusinvasion and dominance. Warmer and drier ecosystems are less resistant to Bromus and are threatened by altered fire regimes which can lead to Bromus dominance, impacts to wildlife, and alternative stable states. Native Americans used fire for manipulating plant communities and may have contributed to the early dominance of Bromus in portions of California. Fire as a tool is now limited to site preparation for revegetation in most ecosystems where Bromus is a significant problem. Once Bromus dominates, breaking annual grass/fire cycles requires restoring fire-tolerant perennial grasses and forbs, which can compete with Bromus and resist its dominance. Current weed management policies often lack regulations to prevent further expansion of Bromus. Research is needed on how and where livestock grazing might help increase perennial grass and forb cover and density to create ecosystems that are more resistant to Bromus. Also, studies are needed to ascertain the role, if any, of oil and gas development in contributing to the spread of Bromus.

  14. KSC-08pd1089

    NASA Image and Video Library

    2008-05-01

    CAPE CANAVERAL, Fla. -- In Firing Room No. 1 in the Launch Control Center at NASA's Kennedy Space Center, panels stretch across the floor in preparation for erecting equipment racks. The firing room will support the future Ares rocket launches as part of the Constellation Program. Future astronauts will ride to orbit on Ares I, which uses a single five-segment solid rocket booster, a derivative of the space shuttle's solid rocket booster, for the first stage. Ares will be launched from Pad 39B, which is being reconfigured from supporting space shuttle launches. The Launch Control Center firing rooms face the launch pads. Photo credit: NASA/Kim Shiflett

  15. Application of water flowing PVC pipe and EPS foam bead as insulation for wall panel

    NASA Astrophysics Data System (ADS)

    Ali, Umi Nadiah; Nor, Norazman Mohamad; Yusuf, Mohammed Alias; Othman, Maidiana; Yahya, Muhamad Azani

    2018-02-01

    Malaysia located in tropical climate which have a typical temperature range between 21 °C to 36 °C. Due to this, air-conditioning system for buildings become a necessity to provide comfort to occupants. In order to reduce the energy consumption of the air-conditioning system, the transmission of heat from outdoor to indoor space should be kept as minimum as possible. This article discuss about a technology to resist heat transfer through concrete wall panel using a hybrid method. In this research, PVC pipe was embedded at the center of concrete wall panel while the EPS foam beads were added about 1% of the cement content in the concrete mix forming the outer layer of the wall panel. Water is regulated in the PVC pipe from the rainwater harvesting system. The aim of this study is to minimize heat transfer from the external environment into the building. Internal building temperature which indicated in BS EN ISO 7730 or ASHRAE Standard 55 where the comfort indoor thermal is below 25°C during the daytime. Study observed that the internal surface temperature of heat resistance wall panel is up to 3°C lower than control wall panel. Therefore, we can conclude that application of heat resistance wall panel can lead to lower interior building temperature.

  16. Generation of advanced fire blight-resistant apple (Malus × domestica) selections of the fifth generation within 7 years of applying the early flowering approach.

    PubMed

    Schlathölter, Ina; Jänsch, Melanie; Flachowsky, Henryk; Broggini, Giovanni Antonio Lodovico; Hanke, Magda-Viola; Patocchi, Andrea

    2018-06-01

    The approach presented here can be applied to reduce the time needed to introduce traits from wild apples into null segregant advanced selections by one-fourth. Interesting traits like resistances to pathogens are often found within the wild apple gene pool. However, the long juvenile phase of apple seedlings hampers the rapid introduction of these traits into new cultivars. The rapid crop cycle breeding approach used in this paper is based on the overexpression of the birch (Betula pendula) MADS4 transcription factor in apple. Using the early flowering line T1190 and 'Evereste' as source of the fire blight resistance (Fb_E locus), we successfully established 18 advanced selections of the fifth generation in the greenhouse within 7 years. Fifteen individuals showed the habitus expected of a regular apple seedling, while three showed very short internodes. The null segregants possessing a regular habitus maintained the high level of fire blight resistance typical for 'Evereste'. Using SSR markers, we estimated the percentage of genetic drag from 'Evereste' still associated with Fb_E on linkage group 12 (LG12). Eight out of the 18 selections had only 4% of 'Evereste' genome left. Since genotypes carrying the apple scab resistance gene Rvi6 and the fire blight resistance QTL Fb_F7 were used as parents in the course of the experiments, these resistances were also identified in some of the null segregants. One seedling is particularly interesting as, beside Fb_E, it also carries Fb_F7 heterozygously and Rvi6 homozygously. If null segregants obtained using this method will be considered as not genetically modified in Europe, as is already the case in the USA, this genotype could be a very promising parent for breeding new fire blight and scab-resistant apple cultivars in European apple breeding programs.

  17. Effect of Experimentally Manipulated Fire Regimes on the Response of Forests to Drought

    NASA Astrophysics Data System (ADS)

    Refsland, T. K.; Knapp, B.; Fraterrigo, J.

    2017-12-01

    Climate change is expected to increase drought stress in many forests and alter fire regimes. Fire can reduce tree density and thus competition for limited water, but the effects of changing fire regimes on forest productivity during drought remain poorly understood. We measured the annual ring-widths of adult oak (Quercus spp.) trees in Mark Twain National Forest, Missouri USA that experienced unburned, annual or periodic (every 4 years) surface fire treatments from 1951 - 2015. Severe drought events were identified using the BILJOU water balance model. We determined the effect of fire treatment on stand-level annual growth rates as well as stand-level resistance and resilience to drought, defined as the drought-induced reduction in growth and post-drought recovery in growth, respectively. During favorable wet years, annual and periodic fire treatments reduced annual growth rates by approximately 10-15% relative to unburned controls (P < 0.001). Stand-level growth rates declined 22-40% during drought events (P < 0.001), but fire-driven changes to stand basal area had no effect on the resistance or resilience of trees to drought. The decline in annual growth rates of burned stands during favorable wet years was likely caused by increased nitrogen (N) limitation in burned plots. After 60 years of treatment, burned plots experienced 30% declines in total soil N relative to unburned plots. Our finding that drought resistance and resilience were similar across all treatments suggest that fire-driven reductions in stand density may have negligible effects on soil moisture availability during drought. Our results highlight that climate-fire interactions can have important long-term effects on forest productivity.

  18. 46 CFR 28.380 - General structural fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... accommodation space must be separated from machinery and fuel tank spaces by a fire resistant boundary which... 46 Shipping 1 2010-10-01 2010-10-01 false General structural fire protection. 28.380 Section 28..., 1991, and That Operate With More Than 16 Individuals on Board § 28.380 General structural fire...

  19. Terminology and biology of fire scars in selected central hardwoods

    Treesearch

    Kevin T. Smith; Elaine Kennedy Sutherland

    2001-01-01

    Dendrochronological analysis of fire scars requires tree survival of fire exposure. Trees survive fire exposure by: (1) avoidance of injury through constitutive protection and (2) induced defense. Induced defenses include (a) compartmentalization processes that resist the spread of injury and infection and (b) closure processes that restore the continuity of the...

  20. Madrean pine-oak forest in Arizona: past dynamics, present problems

    Treesearch

    Andrew M. Barton

    2008-01-01

    This paper synthesizes research on presettlement dynamics and modern disruption of Madrean pine-oak forests in Arizona. In response to surface fires characteristic of presettlement times, pines were fire resistant, exhibiting high top-survival, whereas oaks were fire resilient, exhibiting lower top-survival but pronounced resprouting. Thus, low-severity fire favors...

  1. Prospecting sugarcane resistance to Sugarcane yellow leaf virus by genome-wide association.

    PubMed

    Debibakas, S; Rocher, S; Garsmeur, O; Toubi, L; Roques, D; D'Hont, A; Hoarau, J-Y; Daugrois, J H

    2014-08-01

    Using GWAS approaches, we detected independent resistant markers in sugarcane towards a vectored virus disease. Based on comparative genomics, several candidate genes potentially involved in virus/aphid/plant interactions were pinpointed. Yellow leaf of sugarcane is an emerging viral disease whose causal agent is a Polerovirus, the Sugarcane yellow leaf virus (SCYLV) transmitted by aphids. To identify quantitative trait loci controlling resistance to yellow leaf which are of direct relevance for breeding, we undertook a genome-wide association study (GWAS) on a sugarcane cultivar panel (n = 189) representative of current breeding germplasm. This panel was fingerprinted with 3,949 polymorphic markers (DArT and AFLP). The panel was phenotyped for SCYLV infection in leaves and stalks in two trials for two crop cycles, under natural disease pressure prevalent in Guadeloupe. Mixed linear models including co-factors representing population structure fixed effects and pairwise kinship random effects provided an efficient control of the risk of inflated type-I error at a genome-wide level. Six independent markers were significantly detected in association with SCYLV resistance phenotype. These markers explained individually between 9 and 14 % of the disease variation of the cultivar panel. Their frequency in the panel was relatively low (8-20 %). Among them, two markers were detected repeatedly across the GWAS exercises based on the different disease resistance parameters. These two markers could be blasted on Sorghum bicolor genome and candidate genes potentially involved in plant-aphid or plant-virus interactions were localized in the vicinity of sorghum homologs of sugarcane markers. Our results illustrate the potential of GWAS approaches to prospect among sugarcane germplasm for accessions likely bearing resistance alleles of significant effect useful in breeding programs.

  2. Two distinct major QTL for resistance to fire blight co-localize on linkage group 12 in apple genotypes 'Evereste' and Malus floribunda clone 821.

    PubMed

    Durel, C-E; Denancé, C; Brisset, M-N

    2009-02-01

    Fire blight, caused by the bacterium Erwinia amylovora, is one of the most destructive diseases of apple (Malus xdomestica) worldwide. No major, qualitative gene for resistance to this disease has been identified so far in apple. A quantitative trait locus (QTL) analysis was performed in two F1 progenies derived from two controled crosses: one between the susceptible rootstock cultivar 'MM106' and the resistant ornamental cultivar 'Evereste' and the other one between the moderately susceptible cultivar 'Golden Delicious' and the wild apple Malus floribunda clone 821, with unknown level of fire blight resistance. Both progenies were inoculated in the greenhouse with the same reference strain of E. amylovora. The length of stem necrosis was scored 7 and 14 days after inoculation. A strong QTL effect was identified in both 'Evereste' and M. floribunda 821 at a similar position on the distal region of linkage group 12 of the apple genome. From 50% to 70% of the phenotypic variation was explained by the QTL in 'Evereste' progeny according to the scored trait. More than 40% of the phenotypic variation was explained by the M. floribunda QTL in the second progeny. It was shown that 'Evereste' and M. floribunda 821 carried distinct QTL alleles at that genomic position. A small additional QTL was identified in 'Evereste' on linkage group 15, which explained about 6% of the phenotypic variation. Although it was not possible to confirm whether or not 'Evereste' and M. floribunda QTL belonged to the same locus or two distinct closely related loci, these QTL can be valuable targets in marker-assisted selection to obtain fire blight resistant apple cultivars and form a starting point for discovering the function of the genes controlling apple fire blight resistance.

  3. Cockpit emergency safety system

    NASA Astrophysics Data System (ADS)

    Keller, Leo

    2000-06-01

    A comprehensive safety concept is proposed for aircraft's experiencing an incident to the development of fire and smoke in the cockpit. Fire or excessive heat development caused by malfunctioning electrical appliance may produce toxic smoke, may reduce the clear vision to the instrument panel and may cause health-critical respiration conditions. Immediate reaction of the crew, safe respiration conditions and a clear undisturbed view to critical flight information data can be assumed to be the prerequisites for a safe emergency landing. The personal safety equipment of the aircraft has to be effective in supporting the crew to divert the aircraft to an alternate airport in the shortest possible amount of time. Many other elements in the cause-and-effect context of the emergence of fire, such as fire prevention, fire detection, the fire extinguishing concept, systematic redundancy, the wiring concept, the design of the power supplying system and concise emergency checklist procedures are briefly reviewed, because only a comprehensive and complete approach will avoid fatal accidents of complex aircraft in the future.

  4. Heat-resistant anemometers for fire research

    Treesearch

    John R. Murray; Clive M. Countryman

    1968-01-01

    Heat-resistant anemometers have been developed for measuring horizontal and vertical air flow in fire behavior studies. The anemometers will continue to produce data as long as the anemometer body is less than 650°F. They can survive brief immersion in flame without major damage. These air-flow sensors have aluminum bodies and rotor hubs and stainless steel...

  5. Fire resistance of engineered wood rim board products.

    Treesearch

    Robert H. White

    2003-01-01

    Engineered wood products, such as oriented strandboard, laminated veneer lumber, and other composite wood products, are being used more often in construction. This includes use as rim boards, which are the components around the perimeter of a floor assembly. This situation has increased the need for information about the fire resistance of these products. In this study...

  6. WILDFIRE IGNITION RESISTANCE ESTIMATOR WIZARD SOFTWARE DEVELOPMENT REPORT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Phillips, M.; Robinson, C.; Gupta, N.

    2012-10-10

    This report describes the development of a software tool, entitled “WildFire Ignition Resistance Estimator Wizard” (WildFIRE Wizard, Version 2.10). This software was developed within the Wildfire Ignition Resistant Home Design (WIRHD) program, sponsored by the U. S. Department of Homeland Security, Science and Technology Directorate, Infrastructure Protection & Disaster Management Division. WildFIRE Wizard is a tool that enables homeowners to take preventive actions that will reduce their home’s vulnerability to wildfire ignition sources (i.e., embers, radiant heat, and direct flame impingement) well in advance of a wildfire event. This report describes the development of the software, its operation, its technicalmore » basis and calculations, and steps taken to verify its performance.« less

  7. 14 CFR 29.853 - Compartment interiors.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... towels, paper, or waste must be at least fire-resistant and must have means for containing possible fires... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Design and Construction Fire Protection § 29.853... and nondecorative coated fabrics, leather, trays and galley furnishings, electrical conduit, thermal...

  8. Edge attachment study for fire-resistant canopies

    NASA Technical Reports Server (NTRS)

    Wintermute, G. E.

    1982-01-01

    Twenty-two resin systems were evaluated in laminate form for possible use as edge attachment material for fire-resistant canopies. The evaluation uncovered an unexpected development when the laminates were subjected to an intense flame: (1) the high-heat-resistant materials could withstand the flame test quite well, but experienced rapid heat transfer through the test specimen; (2) the laminates which exhibited a low rate of heat transfer were materials which lost strength rapidly in the presence of the flame by decomposition, delamination, and blistering.

  9. Fire Resistant Composite Closed Cell Foam and Nonwoven Textiles for Tents and Shelters

    DTIC Science & Technology

    2006-01-01

    when heated. The heat causes the plasticizer to dissolve in the PVC to form a flexible, plasticized PVC film . The foam and/or fabric surfaces were...PVC/NBR AF-U9D foam formed a char and only the edge of the material was damaged. These data suggested that burn-through resistance , in addition to...AFRL-ML-TY-TR-2006-4571 FIRE RESISTANT COMPOSITE CLOSED CELL FOAM AND NONWOVEN TEXTILES FOR TENTS AND SHELTERS Stephen C. Davis

  10. Development Test 1 Advanced Attack Helicopter Competitive Evaluation Hughes YAH-64 Helicopter

    DTIC Science & Technology

    1976-12-01

    pilot or the copilot/gunner. The gun/rocket firing circuits were armed by selecting either guns or rockets on the armament panel (fig. 36, app B). The...number of 30mm rounds to be fired and gun barrel positions could only be set from the gunner position for DT I testing. Once the systems were armed ...fuselage is of a semimonocoque construction of primarily aluminum alloys. It consists of 10 major bulkheads and frames and 8 major longerons and

  11. Connective Heating Improvement for Emergency Fire Shelters (CHIEFS): Composition and Performance of Fire Shelter Concepts at Close-Out

    NASA Technical Reports Server (NTRS)

    Fody, Joshua M.; Daryabeigi, Kamran; Bruce, Walter E., III; Wells, John M.; Wusk, Mary E.; Calomino, Anthony M.; Miller, Steve D.

    2018-01-01

    Summary of highlights of the Convective Heating Improvement for Emergency Fire Shelters (CHIEFS) taskunder NASA. CHIEFS was tasked with providing the US Forest Service with an emergency fire shelter forimproved resistance to flame contact. Emphasis is on the final shelter designs at task close-out (end of FY17).

  12. Resistance of eastern hardwood stems to fire injury and damage

    Treesearch

    Kevin T. Smith; Elaine Kennedy Sutherland

    2006-01-01

    This paper reviews the protective features and defensive responses of eastern hardwood species exposed to fire. Trees survive fire through protective features such as thick bark and the induced defenses of compartmentalization. Dissection of trees exposed to prescribed fire in an oak forest in southern Ohio highlights the need to distinguish between bark scorch, stem...

  13. Environmental Panels as a Proxy for Nursing Facility Patients With Methicillin-Resistant Staphylococcus Aure and Vancomycin-Resistant Enterococcus Colonization.

    PubMed

    Cassone, Marco; Mantey, Julia; Perri, Mary Beth; Gibson, Kristen; Lansing, Bonnie; McNamara, Sara; Patel, Payal K; Cheng, Vincent C C; Walters, Maroya S; Stone, Nimalie D; Zervos, Marcus J; Mody, Lona

    2018-05-02

    Most nursing facilities (NFs) lack methicillin-resistant Staphylococcus aureus (MRSA) and vancomycin-resistant Enterococcus (VRE) surveillance programs due to limited resources and high costs. We investigated the utility of environmental screening of high-touch surfaces in patient rooms as a way to circumvent these challenges. We compared MRSA and VRE culture data from high-touch surfaces in patients' rooms (14450 samples from 6 NFs) and ranked each site's performance in predicting patient colonization (7413 samples). The best-performing sites were included in a MRSA- and a VRE-specific panel that functioned as a proxy for patient colonization. Molecular typing was performed to confirm available concordant patient-environment pairs. We identified and validated a MRSA panel that consisted of the bed controls, nurse call button, bed rail, and TV remote control. The VRE panel included the toilet seat, bed controls, bed rail, TV remote control, and top of the side table. Panel colonization data tracked patient colonization. Negative predictive values were 89%-92% for MRSA and 82%-84% for VRE. Molecular typing confirmed a strong clonal type relationship in available concordant patient-environment pairs (98% for MRSA, 91% for VRE), pointing to common epidemiological patterns for environmental and patient isolates. Environmental panels used as a proxy for patient colonization and incorporated into facility surveillance protocols can guide decolonization strategies, improve awareness of MRSA and VRE burden, and inform efforts to reduce transmission. Targeted environmental screening may be a viable surveillance strategy for MRSA and VRE detection in NFs.

  14. Fire safety evaluation of aircraft lavatory and cargo compartments

    NASA Technical Reports Server (NTRS)

    Kourtides, D. A.; Parker, J. A.; Hilado, C. J.; Anderson, R. A.; Tustin, E.; Arnold, D. B.; Gaume, J. G.; Binding, A. T.; Mikeska, J. L.

    1976-01-01

    A program of experimental fires has been carried out to assess fire containment and other fire hazards in lavatory and cargo compartments of wide-body jet aircraft by evaluation of ignition time, burn-through time, fire spread rate, smoke density, evolution of selected combustible and toxic gases, heat flux, and detector response. Two tests were conducted: one involving a standard Boeing 747 lavatory and one involving a simulated DC-10 cargo compartment. A production lavatory module was furnished with conventional materials and was installed in an enclosure. The ignition load was four polyethylene bags containing paper and plastic waste materials representive of a maximum flight cabin waste load. Standard aircraft ventilation conditions were utilized and the lavatory door was closed during the test. Lavatory wall and ceiling panels contained the fire spread during the 30-minute test. Smoke was driven into the enclosure primarily through the ventilation grille in the door and through the gaps between the bifold door and the jamb where the door distorted from the heat earlier in the test. The interior of the lavatory was almost completely destroyed by the fire.

  15. Fighting fire with fire: mass antimalarial drug administrations in an era of antimalarial resistance.

    PubMed

    von Seidlein, Lorenz; Dondorp, Arjen

    2015-06-01

    The emergence and spread of antimalarial resistance has been a major liability for malaria control. The spread of chloroquine-resistant Plasmodium falciparum strains had catastrophic consequences for people in malaria-endemic regions, particularly in sub-Saharan Africa. The recent emergence of artemisinin-resistant P. falciparum strains is of highest concern. Current efforts to contain artemisinin resistance have yet to show success. In the absence of more promising plans, it has been suggested to eliminate falciparum malaria from foci of artemisinin resistance using a multipronged approach, including mass drug administrations. The use of mass drug administrations is controversial as it increases drug pressure. Based on current knowledge it is difficult to conceptualize how targeted malaria elimination could contribute to artemisinin resistance, provided a full treatment course is ensured.

  16. Genome-Wide Association Mapping Reveals Novel QTL for Seedling Leaf Rust Resistance in a Worldwide Collection of Winter Wheat.

    PubMed

    Li, Genqiao; Xu, Xiangyang; Bai, Guihua; Carver, Brett F; Hunger, Robert; Bonman, J Michael; Kolmer, James; Dong, Hongxu

    2016-11-01

    Leaf rust of wheat ( L.) is a major disease that causes significant yield losses worldwide. The short-lived nature of leaf rust resistance () genes necessitates a continuous search for novel sources of resistance. We performed a genome-wide association study (GWAS) on a panel of 1596 wheat accessions. The panel was evaluated for leaf rust reaction by testing with a bulk of Eriks. () isolates collected from multiple fields of Oklahoma in 2013 and two predominant races in the fields of Oklahoma in 2015. The panel was genotyped with a set of 5011 single-nucleotide polymorphism (SNP) markers. A total of 14 quantitative trait loci (QTL) for leaf rust resistance were identified at a false discovery rate (FDR) of 0.01 using the mixed linear model (MLM). Of these, eight QTL reside in the vicinity of known genes or QTL, and more studies are needed to determine their relationship with known loci. is a new QTL to bread wheat but is close to a locus previously identified in durum wheat [ L. subsp. (Desf.) Husn.]. The other five QTL, including , , , , and , are likely novel loci for leaf rust resistance. The uneven distribution of the 14 QTL in the six subpopulations of the panel suggests that wheat breeders can enhance leaf rust resistance by selectively introgressing some of these QTL into their breeding materials. In addition, another 31 QTL were significantly associated with leaf rust resistance at a FDR of 0.05. Copyright © 2016 Crop Science Society of America.

  17. Extra-epitopic hepatitis C virus polymorphisms confer resistance to broadly neutralizing antibodies by modulating binding to scavenger receptor B1.

    PubMed

    El-Diwany, Ramy; Cohen, Valerie J; Mankowski, Madeleine C; Wasilewski, Lisa N; Brady, Jillian K; Snider, Anna E; Osburn, William O; Murrell, Ben; Ray, Stuart C; Bailey, Justin R

    2017-02-01

    Broadly-neutralizing monoclonal antibodies (bNAbs) may guide vaccine development for highly variable viruses including hepatitis C virus (HCV), since they target conserved viral epitopes that could serve as vaccine antigens. However, HCV resistance to bNAbs could reduce the efficacy of a vaccine. HC33.4 and AR4A are two of the most potent anti-HCV human bNAbs characterized to date, binding to highly conserved epitopes near the amino- and carboxy-terminus of HCV envelope (E2) protein, respectively. Given their distinct epitopes, it was surprising that these bNAbs showed similar neutralization profiles across a panel of natural HCV isolates, suggesting that some viral polymorphisms may confer resistance to both bNAbs. To investigate this resistance, we developed a large, diverse panel of natural HCV envelope variants and a novel computational method to identify bNAb resistance polymorphisms in envelope proteins (E1 and E2). By measuring neutralization of a panel of HCV pseudoparticles by 10 μg/mL of each bNAb, we identified E1E2 variants with resistance to one or both bNAbs, despite 100% conservation of the AR4A binding epitope across the panel. We discovered polymorphisms outside of either binding epitope that modulate resistance to both bNAbs by altering E2 binding to the HCV co-receptor, scavenger receptor B1 (SR-B1). This study is focused on a mode of neutralization escape not addressed by conventional analysis of epitope conservation, highlighting the contribution of extra-epitopic polymorphisms to bNAb resistance and presenting a novel mechanism by which HCV might persist even in the face of an antibody response targeting multiple conserved epitopes.

  18. Forest Fire Mapping

    NASA Technical Reports Server (NTRS)

    1990-01-01

    The Fire Logistics Airborne Mapping Equipment (FLAME) system, mounted in a twin-engine and airplane operated by the U.S. Forest Service (USFS) of the U.S. Department of Agriculture (USDA), is an airborne instrument for detecting and pinpointing forest fires that might escape ground detection. The FLAME equipment rack includes the operator interface, a video monitor, the system's control panel and film output. FLAME's fire detection sensor is an infrared line scanner system that identifies fire boundaries. Sensor's information is correlated with the aircraft's position and altitude at the time the infrared imagery is acquired to fix the fire's location on a map. System can be sent to a fire locale anywhere in the U.S. at the request of a regional forester. USFS felt a need for a more advanced system to deliver timely fire information to fire management personnel in the decade of the 1990s. The Jet Propulsion Laboratory (JPL) conducted a study, jointly sponsored by NASA and USDA, on what advanced technologies might be employed to produce an end-to-end thermal infrared fire detection and mapping system. That led to initiation of the Firefly system, currently in development at JPL and targeted for operational service beginning in 1992. Firefly will employ satellite-reference position fixing and provide performance superior to FLAME.

  19. Identification of QTLs for resistance to fire blight (Erwinia amylovora) in Malus sieversii

    USDA-ARS?s Scientific Manuscript database

    Malus sieversii (Ms) is the progenitor of the domestic apple. Ms PI613981 is elite scion material collected at a xerophytic site in Kazakhstan from a tree free of disease and insect damage. The F1 family GMAL4593 (‘Royal Gala’ X PI631981) is segregating for resistance to both apple scab and fire bl...

  20. Light weight fire resistant graphite composites

    NASA Technical Reports Server (NTRS)

    Kourtides, D. A.; Parker, J. A.; Hsu, M. T. S.

    1986-01-01

    Composite structures with a honeycomb core and characterized by lightweight and excellent fire resistance are provided. These sandwich structures employ facesheets made up of bismaleimide-vinyl styrylpyridine copolymers with fiber reinforcement such as carbon fiber reinforcement. In preferred embodiments the facesheets are over layered with a decorative film. The properties of these composites make them attractive materials of construction aircraft and spacecraft.

  1. Ecofriendly Fire Retardant and Rot Resistance Finishing of Jute Fabric Using Tin and Boron Based Compound

    NASA Astrophysics Data System (ADS)

    Samanta, Ashis Kumar; Bagchi, Arindam

    2017-06-01

    Treatment with sodium stannate followed by treatment with boric acid imparts jute fabric wash fast fire resistance property as indicated by its Limiting Oxygen Index (LOI) value and 45° inclined flammability test results. The treatment was carried out by impregnation of sodium stannate followed by impregnation with an aqueous solution of boric acid and drying. Application of sodium stannate (20%) and boric acid (20%) treatment on jute fabric showed balanced flame retardancy property (LOI value 34) with some loss in fabric tenacity (loss of tenacity is 14.5%). Treated fabric retained good fire retardant property after three consecutive washing. Treated fabric also possessed good rot resistance property as indicated by soil burial test and strength retention after 21 days soil burial was found to be 65%. It is found that of sodium stannate and boric acid combination by double bath process form a synergistic durable fire-retardant as well as rot resistant when impregnated on jute material, which is considerably greater than the use of either sodium stannate or boric acid alone. TGA, FTIR and SEM analysis are also reported to support the results and reaction mechanism.

  2. 40 CFR 763.163 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... asbestos-containing product which is made of paper intended for use as general insulation paper or muffler paper. Major applications of commercial papers are insulation against fire, heat transfer, and corrosion... include: thermal insulation for pipe coverings; block insulation; panel insulation in elevators...

  3. 40 CFR 763.163 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... asbestos-containing product which is made of paper intended for use as general insulation paper or muffler paper. Major applications of commercial papers are insulation against fire, heat transfer, and corrosion... include: thermal insulation for pipe coverings; block insulation; panel insulation in elevators...

  4. 40 CFR 763.163 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... asbestos-containing product which is made of paper intended for use as general insulation paper or muffler paper. Major applications of commercial papers are insulation against fire, heat transfer, and corrosion... include: thermal insulation for pipe coverings; block insulation; panel insulation in elevators...

  5. 40 CFR 763.163 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... asbestos-containing product which is made of paper intended for use as general insulation paper or muffler paper. Major applications of commercial papers are insulation against fire, heat transfer, and corrosion... include: thermal insulation for pipe coverings; block insulation; panel insulation in elevators...

  6. 40 CFR 763.163 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... asbestos-containing product which is made of paper intended for use as general insulation paper or muffler paper. Major applications of commercial papers are insulation against fire, heat transfer, and corrosion... include: thermal insulation for pipe coverings; block insulation; panel insulation in elevators...

  7. A Multi-Objective Advanced Design Methodology of Composite Beam-to-Column Joints Subjected to Seismic and Fire Loads

    NASA Astrophysics Data System (ADS)

    Pucinotti, Raffaele; Ferrario, Fabio; Bursi, Oreste S.

    2008-07-01

    A multi-objective advanced design methodology dealing with seismic actions followed by fire on steel-concrete composite full strength joints with concrete filled tubes is proposed in this paper. The specimens were designed in detail in order to exhibit a suitable fire behaviour after a severe earthquake. The major aspects of the cyclic behaviour of composite joints are presented and commented upon. The data obtained from monotonic and cyclic experimental tests have been used to calibrate a model of the joint in order to perform seismic simulations on several moment resisting frames. A hysteretic law was used to take into account the seismic degradation of the joints. Finally, fire tests were conducted with the objective to evaluate fire resistance of the connection already damaged by an earthquake. The experimental activity together with FE simulation demonstrated the adequacy of the advanced design methodology.

  8. 30 CFR 7.64 - Technical requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... produce the required firing current is attained. (d) Firing switch. The switch used to initiate the... current is available to the blasting circuit. (e) Firing line terminals. The terminals used to connect the blasting circuit to the blasting unit shall— (1) Provide a secure, low-resistance connection to the...

  9. 30 CFR 7.64 - Technical requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... produce the required firing current is attained. (d) Firing switch. The switch used to initiate the... current is available to the blasting circuit. (e) Firing line terminals. The terminals used to connect the blasting circuit to the blasting unit shall— (1) Provide a secure, low-resistance connection to the...

  10. Bark heat resistance of small trees in Californian mixed conifer forests: Testing some model assumptions

    USGS Publications Warehouse

    van Mantgem, Phillip J.; Schwartz, Mark

    2003-01-01

    An essential component to models of fire-caused tree mortality is an assessment of cambial damage. Cambial heat resistance has been traditionally measured in large overstory trees with thick bark, although small trees have thinner bark and thus are more sensitive to fire. We undertook this study to determine if current models of bark heat transfer are applicable to small trees (<20 cm diameter at breast height (dbh)). We performed this work in situ on four common species in the mixed conifer forests of the Sierra Nevada, California.The allometric relationship between bole diameter and bark thickness for each species was linear, even for very small trees (5 cm dbh). Heating experiments demonstrated that bark thickness was the primary determinant of cambial heat resistance. We found only slight, but statistically significant, among species differences in bark thermal properties. Our most significant finding was that small trees were more resistant to heating than expected from commonly used models of bark heat transfer. Our results may differ from those of existing models because we found smaller trees to have a greater proportion of inner bark, which appears to have superior insulating properties compared to outer bark. From a management perspective, growth projections suggest that a 50-year fire-free interval may allow some fire intolerant species to achieve at least some degree of cambial heat resistance in the Sierra Nevada.

  11. Circuits in the Sun: Solar Panel Physics

    ERIC Educational Resources Information Center

    Gfroerer, Tim

    2013-01-01

    Typical commercial solar panels consist of approximately 60 individual photovoltaic cells connected in series. Since the usual Kirchhoff rules apply, the current is uniform throughout the circuit, while the electric potential of the individual devices is cumulative. Hence, a solar panel is a good analog of a simple resistive series circuit, except…

  12. Naturally selected hepatitis C virus polymorphisms confer broad neutralizing antibody resistance.

    PubMed

    Bailey, Justin R; Wasilewski, Lisa N; Snider, Anna E; El-Diwany, Ramy; Osburn, William O; Keck, Zhenyong; Foung, Steven K H; Ray, Stuart C

    2015-01-01

    For hepatitis C virus (HCV) and other highly variable viruses, broadly neutralizing mAbs are an important guide for vaccine development. The development of resistance to anti-HCV mAbs is poorly understood, in part due to a lack of neutralization testing against diverse, representative panels of HCV variants. Here, we developed a neutralization panel expressing diverse, naturally occurring HCV envelopes (E1E2s) and used this panel to characterize neutralizing breadth and resistance mechanisms of 18 previously described broadly neutralizing anti-HCV human mAbs. The observed mAb resistance could not be attributed to polymorphisms in E1E2 at known mAb-binding residues. Additionally, hierarchical clustering analysis of neutralization resistance patterns revealed relationships between mAbs that were not predicted by prior epitope mapping, identifying 3 distinct neutralization clusters. Using this clustering analysis and envelope sequence data, we identified polymorphisms in E2 that confer resistance to multiple broadly neutralizing mAbs. These polymorphisms, which are not at mAb contact residues, also conferred resistance to neutralization by plasma from HCV-infected subjects. Together, our method of neutralization clustering with sequence analysis reveals that polymorphisms at noncontact residues may be a major immune evasion mechanism for HCV, facilitating viral persistence and presenting a challenge for HCV vaccine development.

  13. Fortifying the forest: thinning and burning increase resistance to a bark beetle outbreak and promote forest resilience.

    PubMed

    Hood, Sharon M; Baker, Stephen; Sala, Anna

    2016-10-01

    Fire frequency in low-elevation coniferous forests in western North America has greatly declined since the late 1800s. In many areas, this has increased tree density and the proportion of shade-tolerant species, reduced resource availability, and increased forest susceptibility to forest insect pests and high-severity wildfire. In response, treatments are often implemented with the goal of increasing ecosystem resilience by increasing resistance to disturbance. We capitalized on an existing replicated study of fire and stand density treatments in a ponderosa pine (Pinus ponderosa)-Douglas-fir (Pseudotsuga menziesii) forest in western Montana, USA, that experienced a naturally occurring mountain pine beetle (MPB; Dendroctonus ponderosae) outbreak 5 yr after implementation of fuels treatments. We explored whether treatment effects on tree-level defense and stand structure affected resistance to MPB. Mortality from MPB was highest in the denser, untreated control and burn-only treatments, with approximately 50% and 39%, respectively, of ponderosa pine killed during the outbreak, compared to almost no mortality in the thin-only and thin-burn treatments. Thinning treatments, with or without fire, dramatically increased tree growth and resin ducts relative to control and burn-only treatments. Prescribed burning did not increase resin ducts but did cause changes in resin chemistry that may have affected MPB communication and lowered attack success. While ponderosa pine remained dominant in the thin and thin-burn treatments after the outbreak, the high pine mortality in the control and burn-only treatment caused a shift in species dominance to Douglas-fir. The high Douglas-fir component in the control and burn-only treatments due to 20th century fire exclusion, coupled with high pine mortality from MPB, has likely reduced resilience of this forest beyond the ability to return to a ponderosa pine-dominated system in the absence of further fire or mechanical treatment. Our results show treatments designed to increase resistance to high-severity fire in ponderosa pine-dominated forests in the Northern Rockies can also increase resistance to MPB, even during an outbreak. This study suggests that fuel and restoration treatments in fire-dependent ponderosa pine forests that reduce tree density increase ecosystem resilience in the short term, while the reintroduction of fire is important for long-term resilience. © 2016 by the Ecological Society of America.

  14. Influence of the silicon carbide deposit on the thermal resistance of fire protection

    NASA Astrophysics Data System (ADS)

    Kim, K. A.; Lemeshev, D. O.

    2018-04-01

    The ceramics samples with structure of SiC-Al2O3-Fireclay having good thermal resistance were received. As materials were used: black α-SiC F-120, corundum α-Al2O3 F-1000 and Kudinovsky fire-clay. As a temporary technological bundle used polyvinyl alcohol (PVA). Thermal stability was determined by method of heat changes.

  15. Fire resistant resilient foams. [for seat cushions

    NASA Technical Reports Server (NTRS)

    Gagliani, J.

    1976-01-01

    Primary program objectives were the formulation, screening, optimization and characterization of open-cell, fire resistant, low-smoke emitting, thermally stable, resilient polyimide foams suitable for seat cushions in commercial aircraft and spacecraft. Secondary program objectives were to obtain maximum improvement of the tension, elongation and tear characteristics of the foams, while maintaining the resiliency, thermal stability, low smoke emission and other desirable attributes of these materials.

  16. Capacity building and predictors of success for HIV-1 drug resistance testing in the Asia-Pacific region and Africa

    PubMed Central

    Land, Sally; Zhou, Julian; Cunningham, Philip; Sohn, Annette H; Singtoroj, Thida; Katzenstein, David; Mann, Marita; Sayer, David; Kantor, Rami

    2013-01-01

    Background The TREAT Asia Quality Assessment Scheme (TAQAS) was developed as a quality assessment programme through expert education and training, for laboratories in the Asia-Pacific and Africa that perform HIV drug-resistance (HIVDR) genotyping. We evaluated the programme performance and factors associated with high-quality HIVDR genotyping. Methods Laboratories used their standard protocols to test panels of human immunodeficiency virus (HIV)-positive plasma samples or electropherograms. Protocols were documented and performance was evaluated according to a newly developed scoring system, agreement with panel-specific consensus sequence, and detection of drug-resistance mutations (DRMs) and mixtures of wild-type and resistant virus (mixtures). High-quality performance was defined as detection of ≥95% DRMs. Results Over 4.5 years, 23 participating laboratories in 13 countries tested 45 samples (30 HIV-1 subtype B; 15 non-B subtypes) in nine panels. Median detection of DRMs was 88–98% in plasma panels and 90–97% in electropherogram panels. Laboratories were supported to amend and improve their test outcomes as appropriate. Three laboratories that detected <80% DRMs in early panels demonstrated subsequent improvement. Sample complexity factors – number of DRMs (p<0.001) and number of DRMs as mixtures (p<0.001); and laboratory performance factors – detection of mixtures (p<0.001) and agreement with consensus sequence (p<0.001), were associated with high performance; sample format (plasma or electropherogram), subtype and genotyping protocol were not. Conclusion High-quality HIVDR genotyping was achieved in the TAQAS collaborative laboratory network. Sample complexity and detection of mixtures were associated with performance quality. Laboratories conducting HIVDR genotyping are encouraged to participate in quality assessment programmes. PMID:23845227

  17. Flame Resistant Foam

    NASA Technical Reports Server (NTRS)

    1984-01-01

    Solimide manufactured by Imi-Tech Corporation, is a lightweight fire resistant material produced under a manufacturing process that allows it to be uniformly foamed. Can be produced in a variety of densities and structural configurations and remains resilient under exposure to temperatures ranging from minus 300 to plus 500 degrees Fahrenheit. Is resistant to open flame and generates virtually no smoke or toxic by-products. Used in aircraft for its superior damping characteristics, lighter weight and fire barrier properties, it's also applicable to ships and surface transportation systems such as transit cars, trains, buses and automobiles.

  18. 78 FR 60294 - Center for Scientific Review; Notice of Closed Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-01

    ... for Scientific Review Special Emphasis Panel; Member Conflict: The Molecular Immunology of Host... Special Emphasis Panel; Member Conflict: Topics in Bacterial Pathogenesis and Antimicrobial Resistance...

  19. 46 CFR 116.423 - Furniture and furnishings.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... ARRANGEMENT Fire Protection § 116.423 Furniture and furnishings. (a) For the purpose of this subpart, rooms containing “fire resistant furnishings” are considered to be those in which: (1) Furniture such as chairs, sofas, and similar items are tested and meet the requirements in UL 1056 “Fire Test of Upholstered...

  20. 46 CFR 116.423 - Furniture and furnishings.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... ARRANGEMENT Fire Protection § 116.423 Furniture and furnishings. (a) For the purpose of this subpart, rooms containing “fire resistant furnishings” are considered to be those in which: (1) Furniture such as chairs, sofas, and similar items are tested and meet the requirements in UL 1056 “Fire Test of Upholstered...

  1. Engineering and Development Program Plan, Aircraft Cabin Fire Safety.

    DTIC Science & Technology

    1980-06-01

    relative to a postcrash fuel fire, or whether advanced materials provide a significant safety benefit in comparison to inservice materials. if either...have always been controlled by early detection and prompt extinguishment action by effectively trained crew members. In addition, the fire resistant...occupants. g. Develop a computer fire test data bank with broad user availability for inservice and candidate cabin interior materials. h. Identify

  2. Influence of forest management alternatives and land type on susceptibility to fire in northern Wisconsin, USA

    Treesearch

    Eric J. Gustafson; Patrick A. Zollner; Brian R. Sturtevant; S. He Hong; David J. Mladenoff

    2004-01-01

    We used the LANDIS disturbance and succession model to study the effects of six alternative vegetation management scenarios on forest succession and the subsequent risk of canopy fire on a 2791 km2 landscape in northern Wisconsin, USA. The study area is a mix of fire-prone and fire-resistant land types. The alternatives vary the spatial...

  3. New fire-fighting water bucket releases its water for a demonstration

    NASA Technical Reports Server (NTRS)

    2000-01-01

    A NASA helicopter releases 324 gallons of water onto a building in a simulated fire control demonstration. The high-impact- resistant flexible plastic bucket will be used for fire protection on property and buildings at Kennedy Space Center. Known as the 'Bambi' bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.

  4. Control of fire blight (Erwinia amylovora) on apple trees with trunk-injected plant resistance inducers and antibiotics and assessment of induction of pathogenesis-related protein genes

    PubMed Central

    Aćimović, Srđan G.; Zeng, Quan; McGhee, Gayle C.; Sundin, George W.; Wise, John C.

    2015-01-01

    Management of fire blight is complicated by limitations on use of antibiotics in agriculture, antibiotic resistance development, and limited efficacy of alternative control agents. Even though successful in control, preventive antibiotic sprays also affect non-target bacteria, aiding the selection for resistance which could ultimately be transferred to the pathogen Erwinia amylovora. Trunk injection is a target-precise pesticide delivery method that utilizes tree xylem to distribute injected compounds. Trunk injection could decrease antibiotic usage in the open environment and increase the effectiveness of compounds in fire blight control. In field experiments, after 1–2 apple tree injections of either streptomycin, potassium phosphites (PH), or acibenzolar-S-methyl (ASM), significant reduction of blossom and shoot blight symptoms was observed compared to water injected control trees. Overall disease suppression with streptomycin was lower than typically observed following spray applications to flowers. Trunk injection of oxytetracycline resulted in excellent control of shoot blight severity, suggesting that injection is a superior delivery method for this antibiotic. Injection of both ASM and PH resulted in the significant induction of PR-1, PR-2, and PR-8 protein genes in apple leaves indicating induction of systemic acquired resistance (SAR) under field conditions. The time separating SAR induction and fire blight symptom suppression indicated that various defensive compounds within the SAR response were synthesized and accumulated in the canopy. ASM and PH suppressed fire blight even after cessation of induced gene expression. With the development of injectable formulations and optimization of doses and injection schedules, the injection of protective compounds could serve as an effective option for fire blight control. PMID:25717330

  5. Engineering fire blight resistance into the apple cultivar 'Gala' using the FB_MR5 CC-NBS-LRR resistance gene of Malus × robusta 5.

    PubMed

    Broggini, Giovanni A L; Wöhner, Thomas; Fahrentrapp, Johannes; Kost, Thomas D; Flachowsky, Henryk; Peil, Andreas; Hanke, Maria-Viola; Richter, Klaus; Patocchi, Andrea; Gessler, Cesare

    2014-08-01

    The fire blight susceptible apple cultivar Malus × domestica Borkh. cv. 'Gala' was transformed with the candidate fire blight resistance gene FB_MR5 originating from the crab apple accession Malus × robusta 5 (Mr5). A total of five different transgenic lines were obtained. All transgenic lines were shown to be stably transformed and originate from different transgenic events. The transgenic lines express the FB_MR5 either driven by the constitutive CaMV 35S promoter and the ocs terminator or by its native promoter and terminator sequences. Phenotyping experiments were performed with Mr5-virulent and Mr5-avirulent strains of Erwinia amylovora, the causal agent of fire blight. Significantly less disease symptoms were detected on transgenic lines after inoculation with two different Mr5-avirulent E. amylovora strains, while significantly more shoot necrosis was observed after inoculation with the Mr5-virulent mutant strain ZYRKD3_1. The results of these experiments demonstrated the ability of a single gene isolated from the native gene pool of apple to protect a susceptible cultivar from fire blight. Furthermore, this gene is confirmed to be the resistance determinant of Mr5 as the transformed lines undergo the same gene-for-gene interaction in the host-pathogen relationship Mr5-E. amylovora. © 2014 Society for Experimental Biology, Association of Applied Biologists and John Wiley & Sons Ltd.

  6. 24 CFR 3280.206 - Fireblocking.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.206 Fireblocking. (a... materials: (1) Minimum one inch nominal lumber, 5/16 inch thick gypsum board, or equivalent fire resistive...

  7. 24 CFR 3280.206 - Fireblocking.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.206 Fireblocking. (a... materials: (1) Minimum one inch nominal lumber, 5/16 inch thick gypsum board, or equivalent fire resistive...

  8. 24 CFR 3280.206 - Fireblocking.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.206 Fireblocking. (a... materials: (1) Minimum one inch nominal lumber, 5/16 inch thick gypsum board, or equivalent fire resistive...

  9. 24 CFR 3280.206 - Fireblocking.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.206 Fireblocking. (a... materials: (1) Minimum one inch nominal lumber, 5/16 inch thick gypsum board, or equivalent fire resistive...

  10. 24 CFR 3280.206 - Fireblocking.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.206 Fireblocking. (a... materials: (1) Minimum one inch nominal lumber, 5/16 inch thick gypsum board, or equivalent fire resistive...

  11. Preliminary investigation of biological resistance, water absorption and swelling of thermally compressed pine wood panels

    Treesearch

    Oner Unsal; S. Nami Kartal; Zeki Candan; Rachel Arango; Carol A. Clausen; Frederick Green

    2008-01-01

    Wood can be modified by compressive, thermal and chemical treatments. Compression of wood under thermal conditions is resulted in densification of wood. This study evaluated decay and termite resistance of thermally compressed pine wood panels at either 5 or 7 MPa and at either 120 or 150°C for one hour. The process caused increases in density and decreases in...

  12. Heat Conductivity Resistance of Concrete Wall Panel by Water Flowing in Different Orientations of Internal PVC pipe

    NASA Astrophysics Data System (ADS)

    Umi, N. N.; Norazman, M. N.; Daud, N. M.; Yusof, M. A.; Yahya, M. A.; Othman, M.

    2018-04-01

    Green building technology and sustainability development is current focus in the world nowadays. In Malaysia and most tropical countries the maximum temperature recorded typically at 35°C. Air-conditioning system has become a necessity in occupied buildings, thereby increasing the cost of electric consumption. The aim of this study is to find out the solution in minimizing heat transfer from the external environment and intentions towards going green. In this study, the experimental work includes testing three types of concrete wall panels. The main heat intervention material in this research is 2 inch diameter Polyvinyl Chloride (PVC) pipe embedded at the center of the concrete wall panel, while the EPS foam beads were added to the cement content in the concrete mix forming the outer layer of the wall panel. Water from the rainwater harvesting system is regulated in the PVC pipe to intervene with the heat conductivity through the wall panel. Results from the experimental works show that the internal surface temperature of these heat resistance wall panels is to 3□C lower than control wall panel from plain interlocking bricks.

  13. Meeting Materials for the December 4-6, 2013 Scientific Advisory Panel

    EPA Pesticide Factsheets

    Meeting Materials for the December 4-6, 2013 Scientific Advisory Panel on Scientific Uncertainties Associated with Corn Rootworm Resistance Monitoring for Bt Corn Plant Incorporated Protectants (PIPs)

  14. Resilience and resistance of sagebrush ecosystems: implications for state and transition models and management treatments

    USGS Publications Warehouse

    Chambers, Jeanne C.; Miller, Richard F.; Board, David I.; Pyke, David A.; Roundy, Bruce A.; Grace, James B.; Schupp, Eugene W.; Tausch, Robin J.

    2014-01-01

    In sagebrush ecosystems invasion of annual exotics and expansion of piñon (Pinus monophylla Torr. and Frem.) and juniper (Juniperus occidentalis Hook., J. osteosperma [Torr.] Little) are altering fire regimes and resulting in large-scale ecosystem transformations. Management treatments aim to increase resilience to disturbance and enhance resistance to invasive species by reducing woody fuels and increasing native perennial herbaceous species. We used Sagebrush Steppe Treatment Evaluation Project data to test predictions on effects of fire vs. mechanical treatments on resilience and resistance for three site types exhibiting cheatgrass (Bromus tectorum L.) invasion and/or piñon and juniper expansion: 1) warm and dry Wyoming big sagebrush (WY shrub); 2) warm and moist Wyoming big sagebrush (WY PJ); and 3) cool and moist mountain big sagebrush (Mtn PJ). Warm and dry (mesic/aridic) WY shrub sites had lower resilience to fire (less shrub recruitment and native perennial herbaceous response) than cooler and moister (frigid/xeric) WY PJ and Mtn PJ sites. Warm (mesic) WY Shrub and WY PJ sites had lower resistance to annual exotics than cool (frigid to cool frigid) Mtn PJ sites. In WY shrub, fire and sagebrush mowing had similar effects on shrub cover and, thus, on perennial native herbaceous and exotic cover. In WY PJ and Mtn PJ, effects were greater for fire than cut-and-leave treatments and with high tree cover in general because most woody vegetation was removed increasing resources for other functional groups. In WY shrub, about 20% pretreatment perennial native herb cover was necessary to prevent increases in exotics after treatment. Cooler and moister WY PJ and especially Mtn PJ were more resistant to annual exotics, but perennial native herb cover was still required for site recovery. We use our results to develop state and transition models that illustrate how resilience and resistance influence vegetation dynamics and management options.

  15. 3. Credit BG. The interior of the control room appears ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. Credit BG. The interior of the control room appears in this view, looking north (0°). The control console in the room center permitted remote control of various propellant grinders and mixers in surrounding buildings. Television monitors (absent from their mounts in this view) permitted direct viewing of operating machinery. From foreground to background: Panel (1) contains OGAR warning light switches for Curing Buildings E-39, E-40, E-41 and E-86; (O=off, G=green safe, A=amber caution, R=red danger) Panel (2) E-85 Oxidizer Dryer Building console: OGAR switch Panel (3) E-84 Oxidizer Grinder Building console: controls for vibrator, feed, and hammer; Panel (4) E-36 Oxidizer Grinder Building console: controls for vibrator, feed, hammer, attritor, and SWECO ("SWECO" undefined) Panels (5) & (6) blank Panel (7) E-38 Mixer & Casting Building console: vacuum pump, blender, heating and cooling controls Panel (8) E-37 Mixer & Casting Building console: motor controls for 1 pint, 1 gallon, 5 gallon and 30 gallon mixers; vacuum pump, deluge (fire suppression), pot up/down, vibrator, feed, and SWECO. - Jet Propulsion Laboratory Edwards Facility, Weigh & Control Building, Edwards Air Force Base, Boron, Kern County, CA

  16. Effect Of Resistance Modification On EML Capacitor Bank Performance

    DTIC Science & Technology

    2009-06-01

    EFFECT OF RESISTANCE MODIFICATION ON EML CAPACITOR BANK PERFORMANCE* B. M. Huhman, J. M. Neri, T. L. Lockner1 Plasma Physics Division, Naval...development of an electromagnetic launcher ( EML ) for surface-fire support and other missions [1]. The Naval Research Laboratory has initiated a...develop and test materials for the study of barrel lifetime in electromagnetic launchers ( EML ) for surface-fire support and other missions [3]. The

  17. Rehabilitation of a 410-MW utility boiler at Costa Sur, Puerto Rico

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosado, R.; Salmeron, M.

    1995-12-31

    To increase unit reliability and availability and to meet the current and future electric power demands in Puerto Rico, the Puerto Rico Electric Power Authority (PREPA) recently performed a scheduled outage rehabilitation of Costa Sur Power Station Unit 5. This major rehabilitation of a 23-year-old, 410 MW, oil-fired boiler was accompanied by the upgrading of the low-pressure turbine with new rotors. The boiler rehabilitation included the replacement of all waterwall floor panels from just below the burner windbox, down to the lower drum. Temporary support was provided for the lower drum and its structural system during the panel replacement. Themore » steam drum internals were completely rehabilitated, with the installation of a new liner and cleaning and repair of other internals as required. The superheater and reheater desuperheater liners were also replaced. In addition, all major components of both the firing system and the air preheaters were replaced. The gas recirculation fan was rehabilitated, and its discharge duct was replaced.« less

  18. Smoldering and Flame Resistant Textiles via Conformal Barrier Formation.

    PubMed

    Zammarano, Mauro; Cazzetta, Valeria; Nazaré, Shonali; Shields, J Randy; Kim, Yeon Seok; Hoffman, Kathleen M; Maffezzoli, Alfonso; Davis, Rick

    2016-12-07

    A durable and flexible silicone-based backcoating (halogen free) is applied to the backside of an otherwise smoldering-prone and flammable fabric. When exposed to fire, cyclic siloxanes (produced by thermal decomposition of the backcoating) diffuse through the fabric in the gas phase. The following oxidation of the cyclic siloxanes forms a highly conformal and thermally stable coating that fully embeds all individual fibers and shields them from heat and oxidation. As a result, the combustion of the fabric is prevented. This is a novel fire retardant mechanism that discloses a powerful approach towards textiles and multifunctional flexible materials with combined smoldering/flaming ignition resistance and fire-barrier properties.

  19. A composite system approach to aircraft cabin fire safety

    NASA Technical Reports Server (NTRS)

    Kourtides, D. A.; Parker, J. A.; Gilwee, W. J., Jr.; Lerner, N. R.; Hilado, C. J.; Labossiere, L. A.; Hsu, M.-T.

    1976-01-01

    The thermochemical and flammability characteristics of two polymeric composites currently in use and seven others being considered for use as aircraft interior panels are described. The properties studied included: (1) limiting oxygen index of the composite constituents; (2) fire containment capability of the composite; (3) smoke evolution from the composite; (4) thermogravimetric analysis; (5) composition of the volatile products of thermal degradation; and (6) relative toxicity of the volatile products of pyrolysis. The performance of high-temperature laminating resins such as bismaleimides is compared with the performance of phenolics and epoxies. The relationship of increased fire safety with the use of polymers with high anaerobic char yield is shown. Processing parameters of one of the bismaleimide composites is detailed.

  20. A composite system approach to aircraft cabin fire safety

    NASA Technical Reports Server (NTRS)

    Kourtides, D. A.; Parker, J. A.; Gilwee, W. J., Jr.; Lerner, N. R.; Hilado, C. J.; Labossiere, L. A.; Hsu, M. T. S.

    1976-01-01

    The thermochemical and flammability characteristics of two polymeric composites currently in use and seven others being considered for use as aircraft interior panels are described. The properties studied included: (1) limiting oxygen index of the composite constituents; (2) fire containment capability of the composite; (3) smoke evolution from the composite; (4) thermogravimetric analysis; (5) composition of the volatile products of thermal degradation; and (6) relative toxicity of the volatile products of pyrolysis. The performance of high temperature laminating resins such as bismaleimides is compared with the performance of phenolics and epoxies. The relationship of increased fire safety with the use of polymers with high anaerobic char yield is shown. Processing parameters of one of the baremaleimide composites are detailed.

  1. Materials research for aircraft fire safety

    NASA Technical Reports Server (NTRS)

    Kourtides, D. A.; Parker, J. A.; Bricker, R. W.

    1976-01-01

    The thermochemical and flammability characteristics of two polymeric composites currently in use and seven others being considered for use as aircraft interior panels are described. The properties studied included: (1) limiting oxygen index of the composite constituents; (2) fire containment capability of the composite; (3) smoke evolution from the composite; (4) thermogravimetric analysis; (5) composition of the volatile products of thermal degradation; and (6) relative toxicity of the volatile products of pyrolysis. The performance of high-temperature laminating resins such as bismaleimides is compared with the performance of phenolics and epoxies. The relationship of increased fire safety with the use of polymers with high anaerobic char yield is shown. Processing parameters of the state-of-the-art and the advanced bismaleimide composites are detailed.

  2. Solution of Fire Protection in Historic Buildings

    NASA Astrophysics Data System (ADS)

    Iringová, Agnes; Idunk, Róbert

    2016-12-01

    The paper introduces optimization of the functional use of renovated spaces in historic buildings in terms of fire risk. It brings assessment of fire protection in the folk house Habánsky Dvor, situated in the village of Veľké Leváre, whose function was changed into the museum. It goes into static analysis of existing load-bearing structures and assessment of their fire resistance according to Eurocodes.

  3. Aircraft Hangar Fire Suppression System Evaluation-Intermediate- Scale Studies

    DTIC Science & Technology

    1999-12-23

    aqueous film forming foam ( AFFF ) extinguishing systems [1]. The overhead AFFF system typically consists of standard closed head sprinklers that...of Water Spray on Fire-Fighting Foam ," Fire Journal, 63 (6), November 1969. 5. MIL-F-24385F, "Fire Extinguishing Agent, Aqueous Film Forming Foam ...extinguishing capability of the foam and the ability of the blanket to resist burnback. When AFFF is applied over a flammable liquid spill

  4. Production rates for crews using hand tools on firelines

    Treesearch

    Lisa Haven; T. Parkin Hunter; Theodore G. Storey

    1982-01-01

    Reported rates at which hand crews construct firelines can vary widely because of differences in fuels, fire and measurement conditions, and fuel resistance-to-control classification schemes. Real-time fire dispatching and fire simulation planning models, however, require accurate estimates of hand crew productivity. Errors in estimating rate of fireline production...

  5. 30 CFR 57.4531 - Surface flammable or combustible liquid storage buildings or rooms.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Installation/construction/maintenance § 57.4531 Surface... fire resistance rating of at least one hour; or (2) Equipped with an automatic fire supression system...

  6. New fire-fighting water bucket is lifted by helicopter

    NASA Technical Reports Server (NTRS)

    2000-01-01

    A NASA helicopter lifts a high-impact-resistant flexible plastic bucket that will be used for fire protection on property and buildings at Kennedy Space Center. Known as the 'Bambi' bucket, the 324-gallon container will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.

  7. 49 CFR 178.358-2 - Materials of construction and other requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Materials of construction and other requirements. (a) Phenolic foam insulation must be fire resistant and... equivalent. (d) Fire-retardant (intumescent) paint must be applied to any wood blocking which is located at... provide pressure relief during the insulation foaming and in the event of a fire. These holes, which must...

  8. Investigation of the seismic resistance of interior building partitions, phase 1

    NASA Astrophysics Data System (ADS)

    Anderson, R. W.; Yee, Y. C.; Savulian, G.; Barclay, B.; Lee, G.

    1981-02-01

    The effective participation of wood-framed interior shear wall partitions when determining the ultimate resistance capacity of two- and three-story masonry apartment buildings to seismic loading was investigated. Load vs. deflection tests were performed on 8 ft by 8 ft wall panel specimens constructed of four different facing materials, including wood lath and plaster, gypsum lath and plaster, and gypsum wallboard with joints placed either horizontally or vertically. The wood lath and plaster construction is found to be significantly stronger and stiffer than the other three specimens. Analyses of the test panels using finite element methods to predict their static resistance characteristics indicates that the facing material acts as the primary shear-resisting structural element. Resistance of shear wall partitions to lateral loads was assessed.

  9. Forest fires in Italy: An econometric analysis of major driving factors

    NASA Astrophysics Data System (ADS)

    Michetti, Melania; Pinar, Mehmet

    2013-04-01

    Despite the relevant fire risk to which Italy is subject from north to south, very few analysis focus on this area. This article investigates the causes of forest fires frequency and intensity in Italy during the first decade of the XXI century. The dynamical aspects of fire danger are explored through the use of panel data techniques which fully capture the impacts on forest fires of changes in both socio-economic and climatic conditions. Italy is treated as a unique region in a first model specification, while it is then split into 3 geographical areas (north, centre, and south) to capture locally specific aspects. Two different dependent variables are alternatively employed and a number of ad hoc tests are performed to corroborate the robustness of our estimates. Results highlight the importance of considering the fire situation separately for the northern, central, and southern parts of Italy. While the presence of railway networks positively affects fire risk, the impact of livestock depends on its specific composition. Favourable effects in fire reduction are represented by the increase in education levels (north and centre) and touristic flows (north and south), and by the containment of illegal activities (south). Weather patterns appear to be important determinants all over the Italian peninsula.

  10. Development of fire resistant, nontoxic aircraft interior materials

    NASA Technical Reports Server (NTRS)

    Haley, G.; Silverman, B.; Tajima, Y.

    1976-01-01

    All available newly developed nonmetallic polymers were examined for possible usage in developing fire resistant, nontoxic nonmetallic parts or assemblies for aircraft interiors. Specifically, feasibility for the development of clear films for new decorative laminates, compression moldings, injection molded parts, thermoformed plastic parts, and flexible foams were given primary considerations. Preliminary data on the flame resistant characteristics of the materials were obtained. Preliminary toxicity data were generated from samples of materials submitted from the contractor. Preliminary data on the physical characteristics of various thermoplastic materials to be considered for either compression molded, injection molded, or thermoformed parts were obtained.

  11. Genome-wide association study in Asia-adapted tropical maize reveals novel and explored genomic regions for sorghum downy mildew resistance.

    PubMed

    Rashid, Zerka; Singh, Pradeep Kumar; Vemuri, Hindu; Zaidi, Pervez Haider; Prasanna, Boddupalli Maruthi; Nair, Sudha Krishnan

    2018-01-10

    Globally, downy mildews are among the important foliar diseases of maize that cause significant yield losses. We conducted a genome-wide association study for sorghum downy mildew (SDM; Peronosclerospora sorghi) resistance in a panel of 368 inbred lines adapted to the Asian tropics. High density SNPs from Genotyping-by-sequencing were used in GWAS after controlling for population structure and kinship in the panel using a single locus mixed model. The study identified a set of 26 SNPs that were significantly associated with SDM resistance, with Bonferroni corrected P values ≤ 0.05. Among all the identified SNPs, the minor alleles were found to be favorable to SDM resistance in the mapping panel. Trend regression analysis with 16 independent genetic variants including 12 SNPs and four haplotype blocks identified SNP S2_6154311 on chromosome 2 with P value 2.61E-24 and contributing 26.7% of the phenotypic variation. Six of the SNPs/haplotypes were within the same chromosomal bins as the QTLs for SDM resistance mapped in previous studies. Apart from this, eight novel genomic regions for SDM resistance were identified in this study; they need further validation before being applied in the breeding pipeline. Ten SNPs identified in this study were co-located in reported mildew resistance genes.

  12. Fire resistant PV shingle assembly

    DOEpatents

    Lenox, Carl J.

    2012-10-02

    A fire resistant PV shingle assembly includes a PV assembly, including PV body, a fire shield and a connection member connecting the fire shield below the PV body, and a support and inter-engagement assembly. The support and inter-engagement assembly is mounted to the PV assembly and comprises a vertical support element, supporting the PV assembly above a support surface, an upper interlock element, positioned towards the upper PV edge, and a lower interlock element, positioned towards the lower PV edge. The upper interlock element of one PV shingle assembly is inter-engageable with the lower interlock element of an adjacent PV shingle assembly. In some embodiments the PV shingle assembly may comprise a ventilation path below the PV body. The PV body may be slidably mounted to the connection member to facilitate removal of the PV body.

  13. Numerical prediction of fire resistance of RC beams

    NASA Astrophysics Data System (ADS)

    Serega, Szymon; Wosatko, Adam

    2018-01-01

    Fire resistance of different structural members is an important issue of their strength and durability. A simple but effective tool to investigate multi-span reinforced concrete beams exposed to fire is discussed in the paper. Assumptions and simplifications of the theory as well as numerical aspects are briefly reviewed. Two steps of nonlinear finite element analysis and two levels of observation are distinguished. The first step is the solution of transient heat transfer problem in representative two-dimensional reinforced concrete cross-section of a beam. The second part is a nonlinear mechanical analysis of the whole beam. All spans are uniformly loaded, but an additional time-dependent thermal load due to fire acts on selected ones. Global changes of curvature and bending moment functions induce deterioration of the stiffness. Benchmarks are shown to confirm the correctness of the model.

  14. Impact of wildfire return interval on the ectomycorrhizal resistant propagules communities of a Mediterranean open forest.

    PubMed

    Buscardo, Erika; Rodríguez-Echeverría, Susana; Martín, María P; De Angelis, Paolo; Pereira, João Santos; Freitas, Helena

    2010-08-01

    Ectomycorrhizal (ECM) fungi, in particular their spores and other resistant propagules, play an important role in secondary succession processes that facilitate regeneration after disturbance events. In this study, the effects of high and low wildfire frequencies (respectively short and long fire return intervals) on the resistant propagules communities (RPCs) of a Mediterranean open pine forest were compared. Soil samples were collected in four mountain sites with different fire return intervals and used to test ectomycorrhiza development in two hosts, Pinus pinaster and Quercus suber. RPCs were characterized by direct sequencing of fungal internal transcribed spacer (ITS) regions from individual ECM root tips. Eighteen ECM species were detected in the bioassay. The most frequently found fungi were Cenococcum geophilum, Inocybe jacobi, Thelephora terrestris, Tomentella ellisii on both hosts and Rhizopogon luteolus and R. roseolus on maritime pine. A short fire return interval reduced the species richness of the ECM community found on Q. suber, promoted species like R. roseolus and reduced the abundance of other species (e.g. R. luteolus). The abundance of I. jacobi was positively affected by long fire return interval, but decreased significantly with recurrent fires. These results indicate that changes in fire frequency can alter the structure, composition and diversity of ECM communities, which could compromise the resilience of the ecosystem in highly disturbed areas. Copyright © 2010 The British Mycological Society. Published by Elsevier Ltd. All rights reserved.

  15. [Effect of porcelain firing cycle on microstructure and corrosion resistance of 4 metal ceramic alloys].

    PubMed

    Chen, Lei; Cai, Hui; Xu, Guo-fu; Fang, Chang-yun

    2006-06-01

    To determine the effect of porcelain firing cycle on microstructure of 4 metal ceramic alloys, and to analyze the changes of their corrosion resistance in the artificial saliva. We simulated the process of firing and repolishing when fabricating porcelain-fused-to-metal restoration in clinic,and then observed the microstructures of Ni-Cr, Ni-Cr-Ti, Co-Cr alloys and high gold alloy by field emission scanning electron microscopy and energy dispersive spectroscopy. The electrochemical corrosion behavior of alloys in artificial saliva was analyzed by polarization curves and corrview 2 corrosion analysis software. The data of self-corrosion potential and transpassive potential were obtained and analyzed. After the porcelain firing cycle, the surface composition changed slightly, and the morphological in the 3 predominate base metal alloys also changed. The self-corrosion potential turned to more negative, and the transpassive potential declined. The procedure of porcelain firing cycle can affect the surface microstructure and increase the corrosion of 4 metal-ceramic alloys.

  16. Geophysical survey for groundwater potential investigation in peat land area, Riau, Indonesia

    NASA Astrophysics Data System (ADS)

    Islami, N.; Irianti, M.; Azhar; Nor, M.; Fakhrudin

    2018-04-01

    Tropical forests, especially peat lands, are particularly vulnerable to forest fires. Fires are the most common disasters in peat lands in the dry season, especially in Riau Province, Indonesia. In the process of extinguishing the peat fire, several substantial problems arise to stop peat fires during this period. This study aims to determine the possibility of using ground water as a source of water to anticipate the early mitigation of peat land fires disaster. The geoelectrical resistivity surveys were used to predict the subsurface geological data including peat thickness and depth of aquifers. The geometry of peat lands was determined using geostatistics based on geoelectrical resistivity interpretation data. Peat Land thickness varies up to 4 m in the north and is thinner to the south. A shallower and deeper aquifer is available at a depth of 13 m to 18 m and 70 m to 90 m respectively. In general, the potential of groundwater in the shallow aquifer is predicted to be sufficient for peat land watering anytime.

  17. Using resistance and resilience concepts to reduce impacts of invasive annual grasses and altered fire regimes on the sagebrush ecosystem and greater sage-grouse: A strategic multi-scale approach

    Treesearch

    Jeanne C. Chambers; David A. Pyke; Jeremy D. Maestas; Mike Pellant; Chad S. Boyd; Steven B. Campbell; Shawn Espinosa; Douglas W. Havlina; Kenneth E. Mayer; Amarina Wuenschel

    2014-01-01

    This Report provides a strategic approach for conservation of sagebrush ecosystems and Greater Sage- Grouse (sage-grouse) that focuses specifically on habitat threats caused by invasive annual grasses and altered fire regimes. It uses information on factors that influence (1) sagebrush ecosystem resilience to disturbance and resistance to invasive annual grasses and (2...

  18. Polymer of phosphonylmethyl-2,4- and -2,6-diamino benzene and polyfunctional monomer

    NASA Technical Reports Server (NTRS)

    Mikroyannidis, J. A. (Inventor); Kourtides, D. A. (Inventor)

    1986-01-01

    A phosphonyl methyl benzene is prepared by nitration to produce a 2,4-dinitro phosphonyl methyl benzene, which is then reduced to a diamino compound. The diamino compound is then used to cure a polymerizable monomer. The diamino compound may be polymerized with polyfunctional epoxides to produce heat and fire resistant polymer structures for making flame and fire resistant polymer structures such as for aircraft secondary structures.

  19. Investigation on Low Firing Copper for Front Electrode of Si-Based Solar Cell Applications.

    PubMed

    Chiang, Chen-Su; Wu, Yia-Ming; Lee, Wen-Hsi

    2018-04-01

    Solar cell is one of the most popular alternative energies. The aim of this study is to construct an ohmic contact between front electrode and Si-based solar cell by a Newly-invented low-cost paste and low temperature sintering process. The core-shell of CucoreAgshell powders were prepared for making high solid content paste, then screen printing the fine line on laser-opening H-pattern silicon substrate and applying firing process. Because the silver coverage is more than 95% and silver nanoparticles start to melt at 200 °C. The shell of nanoparticles of silver not only is used to prevent copper from oxidized, but also connected core Cu particles for enhancing the conductivity of CucoreAgshell. TEM, EDS, SEM were used to examine the microstructure of CucoreAgshell. Fourpoint probe and transmission line model were employed to analyze the sheet resistance and the specific contact resistance. The lowest specific contact resistivity is 0.005 Ωcm2, sheet resistance is 0.0138 Ω/ and the lowest resistivity of front electrode measured is 2.65 × 10-5 Ωcm when CucoreAgshell paste with 94 wt% solid content was fired at 550 °C.

  20. Design and development of polyphenylene oxide foam as a reusable internal insulation for LH2 tanks, phase 2

    NASA Technical Reports Server (NTRS)

    1972-01-01

    PPO form was tested for mechanical strength, for the effects of 100 thermal cycles from 450 K (359 F) to 21 K (-423 F) and for gas flow resistance characteristics. PPO foam panels were investigated for density variations, methods for joining panels were studied and panel joint thermal test specimens were fabricated. The range of foam panel thickness under investigation was extended to include 7 mm (0.3 in) and 70 mm (2.8 in) panels which also were tested for thermal performance.

  1. New Trends in Reaction and Resistance to Fire of Fire-retardant Epoxies

    PubMed Central

    Gérard, Caroline; Fontaine, Gaëlle; Bourbigot, Serge

    2010-01-01

    This paper focuses on current trends in the flame retardancy of epoxy-based thermosets. This review examines the incorporation of additives in these polymers, including synergism effects. Reactive flame-retardants—which are incorporated in the polymer backbone—are reported and the use of fire-retardant epoxy coatings for materials protection is also considered. PMID:28883337

  2. 49 CFR Appendix B to Part 238 - Test Methods and Performance Criteria for the Flammability and Smoke Emission Characteristics of...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., etc.) shall be designed against acting as passageways for fire and smoke and representative... structural flooring assembly to perform as a barrier against under-vehicle fires. The fire resistance period... Flammability and Smoke Emission Characteristics of Materials Used in Passenger Cars and Locomotive Cabs B...

  3. 29 CFR 1910.36 - Design and construction requirements for exit routes.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... that remains closed or automatically closes in an emergency upon the sounding of a fire alarm or employee alarm system. Each fire door, including its frame and hardware, must be listed or approved by a... route must be a permanent part of the workplace. (2) An exit must be separated by fire resistant...

  4. 29 CFR 1910.36 - Design and construction requirements for exit routes.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... that remains closed or automatically closes in an emergency upon the sounding of a fire alarm or employee alarm system. Each fire door, including its frame and hardware, must be listed or approved by a... route must be a permanent part of the workplace. (2) An exit must be separated by fire resistant...

  5. New fire-fighting water bucket is readied for a demonstration

    NASA Technical Reports Server (NTRS)

    2000-01-01

    Workers attach a high-impact-resistant flexible plastic bucket to a NASA helicopter. Holding 324 gallons of water, it will be used for fire protection on property and buildings at Kennedy Space Center. Known as the 'Bambi' bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.

  6. New fire-fighting water bucket is filled for demonstration

    NASA Technical Reports Server (NTRS)

    2000-01-01

    - A NASA helicopter hovers over the water while a high-impact- resistant flexible plastic bucket fills. The 324-gallon container will be used for fire protection on property and buildings at Kennedy Space Center. Known as the 'Bambi' bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.

  7. New fire-fighting water bucket is lifted from water for a demonstration

    NASA Technical Reports Server (NTRS)

    2000-01-01

    A NASA helicopter lifts a high-impact-resistant flexible plastic bucket filled with water. The container will be used for fire protection on property and buildings at Kennedy Space Center.. Known as the 'Bambi' bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.

  8. Extinguishment and Burnback Testing of Fire Fighting Agents

    DTIC Science & Technology

    2005-09-26

    resisting burnback for hydrocarbon fuel fires. Potential Aqueous Film Forming Foam ( AFFF ) replacements are required to exhibit an...simple, reliable test to evaluate the effectiveness of new foams being introduced into the market as potential Aqueous Film Forming Foam ( AFFF ...normal concentrations. Reference: Military Specification MIL-F-24385F, Fire Extinguishing Agent, Aqueous Film - Forming Foam

  9. Mechanical properties of gypsum board at elevated temperatures

    Treesearch

    S.M. Cramer; O.M. Friday; R.H. White; G. Sriprutkiat

    2003-01-01

    Gypsum board is a common fire barrier used in house and general building construction. Recently, evaluation of the collapses of the World Trade Center Towers highlighted the potential role and failure of gypsum board in containing the fires and resisting damage. The use of gypsum board as primary fire protection of light-flame wood or steel construction is ubiquitous....

  10. An assessment of three different fire resistance tests for hydraulic fluids

    NASA Astrophysics Data System (ADS)

    Loftus, J. J.

    1981-10-01

    The Center for Fire Research at the National Bureau of Standards at the request of the Mine Safety and Health Administration (MSHA) and the Bureau of Mines made an evaluation or assessment of the three different flammability tests used by MSHA for measuring the fire resistance of hydraulic fluids intended for use in underground coal mining operations. The methods described in the Code of Federal Regulations Schedule 30, Part 35, consist of the following: an Autogenous Ignition Temperature Test, a Temperature-Pressure Spray Ignition Test, and a Test to Determine the Effect of Evaporation on the Flammability of Hydraulic Fluids. Recommendations for improvement of the three test procedures are provided.

  11. Dynamic Response and Optimal Design of Curved Metallic Sandwich Panels under Blast Loading

    PubMed Central

    Yang, Shu; Han, Shou-Hong; Lu, Zhen-Hua

    2014-01-01

    It is important to understand the effect of curvature on the blast response of curved structures so as to seek the optimal configurations of such structures with improved blast resistance. In this study, the dynamic response and protective performance of a type of curved metallic sandwich panel subjected to air blast loading were examined using LS-DYNA. The numerical methods were validated using experimental data in the literature. The curved panel consisted of an aluminum alloy outer face and a rolled homogeneous armour (RHA) steel inner face in addition to a closed-cell aluminum foam core. The results showed that the configuration of a “soft” outer face and a “hard” inner face worked well for the curved sandwich panel against air blast loading in terms of maximum deflection (MaxD) and energy absorption. The panel curvature was found to have a monotonic effect on the specific energy absorption (SEA) and a nonmonotonic effect on the MaxD of the panel. Based on artificial neural network (ANN) metamodels, multiobjective optimization designs of the panel were carried out. The optimization results revealed the trade-off relationships between the blast-resistant and the lightweight objectives and showed the great use of Pareto front in such design circumstances. PMID:25126606

  12. Dynamic response and optimal design of curved metallic sandwich panels under blast loading.

    PubMed

    Qi, Chang; Yang, Shu; Yang, Li-Jun; Han, Shou-Hong; Lu, Zhen-Hua

    2014-01-01

    It is important to understand the effect of curvature on the blast response of curved structures so as to seek the optimal configurations of such structures with improved blast resistance. In this study, the dynamic response and protective performance of a type of curved metallic sandwich panel subjected to air blast loading were examined using LS-DYNA. The numerical methods were validated using experimental data in the literature. The curved panel consisted of an aluminum alloy outer face and a rolled homogeneous armour (RHA) steel inner face in addition to a closed-cell aluminum foam core. The results showed that the configuration of a "soft" outer face and a "hard" inner face worked well for the curved sandwich panel against air blast loading in terms of maximum deflection (MaxD) and energy absorption. The panel curvature was found to have a monotonic effect on the specific energy absorption (SEA) and a nonmonotonic effect on the MaxD of the panel. Based on artificial neural network (ANN) metamodels, multiobjective optimization designs of the panel were carried out. The optimization results revealed the trade-off relationships between the blast-resistant and the lightweight objectives and showed the great use of Pareto front in such design circumstances.

  13. The Command and Control Reference Model for Modeling, Simulations, and Technology Applications

    DTIC Science & Technology

    1994-01-20

    NUMBER Basic Research Group (BRG), Technical Panel for C3 (TPC3) Joint Directors of Laboratories (JDL) JDL TPC3 BRG NRaD, San Diego , CA 92152; RADC...wind, ionization, pressure, pollution, ... mesofeature (weather, man-made) cloud, storm, fog, smog, dust, fire, jet stream, smoke, aurora borealis

  14. Fire performance of oriented strandboard

    Treesearch

    Robert H. White; Jerrold E. Winandy

    2006-01-01

    Wood-based composites represent a continuously increasing share of the wood products market. Commercial construction will be important for future expansion of the structural panels market. Use of engineered wood products as an alternative to traditional solid wood lumber is also increasing. A recent series of cone calorimeter tests evaluated the performance of several...

  15. Analysis of the ability of large-scale reanalysis data to define Siberian fire danger in preparation for future fire prediction

    NASA Astrophysics Data System (ADS)

    Soja, Amber; Westberg, David; Stackhouse, Paul, Jr.; McRae, Douglas; Jin, Ji-Zhong; Sukhinin, Anatoly

    2010-05-01

    Fire is the dominant disturbance that precipitates ecosystem change in boreal regions, and fire is largely under the control of weather and climate. Fire frequency, fire severity, area burned and fire season length are predicted to increase in boreal regions under current climate change scenarios. Therefore, changes in fire regimes have the potential to compel ecological change, moving ecosystems more quickly towards equilibrium with a new climate. The ultimate goal of this research is to assess the viability of large-scale (1°) data to be used to define fire weather danger and fire regimes, so that large-scale data can be confidently used to predict future fire regimes using large-scale fire weather data, like that available from current Intergovernmental Panel on Climate Change (IPCC) climate change scenarios. In this talk, we intent to: (1) evaluate Fire Weather Indices (FWI) derived using reanalysis and interpolated station data; (2) discuss the advantages and disadvantages of using these distinct data sources; and (3) highlight established relationships between large-scale fire weather data, area burned, active fires and ecosystems burned. Specifically, the Canadian Forestry Service (CFS) Fire Weather Index (FWI) will be derived using: (1) NASA Goddard Earth Observing System version 4 (GEOS-4) large-scale reanalysis and NASA Global Precipitation Climatology Project (GPCP) data; and National Climatic Data Center (NCDC) surface station-interpolated data. Requirements of the FWI are local noon surface-level air temperature, relative humidity, wind speed, and daily (noon-noon) rainfall. GEOS-4 reanalysis and NCDC station-interpolated fire weather indices are generally consistent spatially, temporally and quantitatively. Additionally, increased fire activity coincides with increased FWI ratings in both data products. Relationships have been established between large-scale FWI to area burned, fire frequency, ecosystem types, and these can be use to estimate historic and future fire regimes.

  16. Whole Exome Sequencing of Patients with Steroid-Resistant Nephrotic Syndrome.

    PubMed

    Warejko, Jillian K; Tan, Weizhen; Daga, Ankana; Schapiro, David; Lawson, Jennifer A; Shril, Shirlee; Lovric, Svjetlana; Ashraf, Shazia; Rao, Jia; Hermle, Tobias; Jobst-Schwan, Tilman; Widmeier, Eugen; Majmundar, Amar J; Schneider, Ronen; Gee, Heon Yung; Schmidt, J Magdalena; Vivante, Asaf; van der Ven, Amelie T; Ityel, Hadas; Chen, Jing; Sadowski, Carolin E; Kohl, Stefan; Pabst, Werner L; Nakayama, Makiko; Somers, Michael J G; Rodig, Nancy M; Daouk, Ghaleb; Baum, Michelle; Stein, Deborah R; Ferguson, Michael A; Traum, Avram Z; Soliman, Neveen A; Kari, Jameela A; El Desoky, Sherif; Fathy, Hanan; Zenker, Martin; Bakkaloglu, Sevcan A; Müller, Dominik; Noyan, Aytul; Ozaltin, Fatih; Cadnapaphornchai, Melissa A; Hashmi, Seema; Hopcian, Jeffrey; Kopp, Jeffrey B; Benador, Nadine; Bockenhauer, Detlef; Bogdanovic, Radovan; Stajić, Nataša; Chernin, Gil; Ettenger, Robert; Fehrenbach, Henry; Kemper, Markus; Munarriz, Reyner Loza; Podracka, Ludmila; Büscher, Rainer; Serdaroglu, Erkin; Tasic, Velibor; Mane, Shrikant; Lifton, Richard P; Braun, Daniela A; Hildebrandt, Friedhelm

    2018-01-06

    Steroid-resistant nephrotic syndrome overwhelmingly progresses to ESRD. More than 30 monogenic genes have been identified to cause steroid-resistant nephrotic syndrome. We previously detected causative mutations using targeted panel sequencing in 30% of patients with steroid-resistant nephrotic syndrome. Panel sequencing has a number of limitations when compared with whole exome sequencing. We employed whole exome sequencing to detect monogenic causes of steroid-resistant nephrotic syndrome in an international cohort of 300 families. Three hundred thirty-five individuals with steroid-resistant nephrotic syndrome from 300 families were recruited from April of 1998 to June of 2016. Age of onset was restricted to <25 years of age. Exome data were evaluated for 33 known monogenic steroid-resistant nephrotic syndrome genes. In 74 of 300 families (25%), we identified a causative mutation in one of 20 genes known to cause steroid-resistant nephrotic syndrome. In 11 families (3.7%), we detected a mutation in a gene that causes a phenocopy of steroid-resistant nephrotic syndrome. This is consistent with our previously published identification of mutations using a panel approach. We detected a causative mutation in a known steroid-resistant nephrotic syndrome gene in 38% of consanguineous families and in 13% of nonconsanguineous families, and 48% of children with congenital nephrotic syndrome. A total of 68 different mutations were detected in 20 of 33 steroid-resistant nephrotic syndrome genes. Fifteen of these mutations were novel. NPHS1 , PLCE1 , NPHS2 , and SMARCAL1 were the most common genes in which we detected a mutation. In another 28% of families, we detected mutations in one or more candidate genes for steroid-resistant nephrotic syndrome. Whole exome sequencing is a sensitive approach toward diagnosis of monogenic causes of steroid-resistant nephrotic syndrome. A molecular genetic diagnosis of steroid-resistant nephrotic syndrome may have important consequences for the management of treatment and kidney transplantation in steroid-resistant nephrotic syndrome. Copyright © 2018 by the American Society of Nephrology.

  17. Heat resistant protective hand covering

    NASA Technical Reports Server (NTRS)

    Tschirch, R. P.; Sidman, K. R.; Arons, I. J. (Inventor)

    1984-01-01

    A heat-resistant aromatic polyamide fiber is described. The outer surface of the shell is coated with a fire-resistant elastomer and liner. Generally conforming and secured to the shell and disposed inwardly of the shell, the liner is made of a felt fabric of temperature-resistant aromatic polymide fiber.

  18. Tropic Test of Bradley Fighting Vehicle Systems.

    DTIC Science & Technology

    1985-05-23

    CM-R AMSTE-SG-H AMSTE-PT-MT AMSTE-RM Aberden Proving Ground , MD 21005-5055 Commander U.S. Army Armament Research and Development Command ATTN: AMSMC...Requirements Appendix E -Vision Devices Appendix F - Grounding Circuit Resistance Appendix G - Human Factors Appendix H - Distribution List -" -"" 3...miles of operation o Time-on-Target Baseline Tests o Selected electrical and grounding circuit resistances o Armament Firing (25mm, 7.62mm and TOW) o Fire

  19. Resistance after firing protected electric match

    DOEpatents

    Montoya, Arsenio P.

    1981-11-10

    An electric match having electrical leads embedded in flame-producing compound is protected against an accidental resistance across the leads after firing by a length of heat-shrinkable tubing encircling the match body and having a skirt portion extending beyond the leads. The heat of the burning match and an adjacent thermal battery causes the tubing to fold over the end of the match body, covering the ends of the leads and protecting them from molten pieces of the battery.

  20. Materials for fire resistant passenger seats in aircraft

    NASA Technical Reports Server (NTRS)

    Tesoro, G.; Moussa, A.

    1980-01-01

    The paper considers the selection of cushioning foam and upholstery fabric materials for aircraft passenger seats. Polyurethane, polychloroprene, polyimide, and polyphosphazene are the foam materials considered; and a variety of commercial and developmental fabrics (including wool, cotton, synthetics, and blends) are examined. Viable approaches to the design of fire-resistant seat assemblies are indicated. Results of an experimental laboratory study of fabrics and fabric/foam assemblies exposed to external point-source radiative heat flux are discussed.

  1. Fire-resistant materials for aircraft passenger seat construction

    NASA Technical Reports Server (NTRS)

    Fewell, L. L.; Tesoro, G. C.; Moussa, A.; Kourtides, D. A.

    1979-01-01

    The thermal response characteristics of fabric and fabric-foam assemblies are described. The various aspects of the ignition behavior of contemporary aircraft passenger seat upholstery fabric materials relative to fabric materials made from thermally stable polymers are evaluated. The role of the polymeric foam backing on the thermal response of the fabric-foam assembly is also ascertained. The optimum utilization of improved fire-resistant fabric and foam materials in the construction of aircraft passenger seats is suggested.

  2. Study to develop improved fire resistant aircraft passenger seat materials, phase 1

    NASA Technical Reports Server (NTRS)

    Trabold, E. L.

    1977-01-01

    The procurement and testing of a wide range of candidate materials is reported. Improved fire resistant nonmetallic materials were subjected to tests to evaluate their thermal characteristics, such as burn, smoke generation, heat release rate and toxicity. In addition, candidate materials were evaluated for mechanical, physical and aesthetic properties. Other properties considered included safety, comfort, durability and maintainability. The fiscal year 1977 and the projected 1980 cost data were obtained for aircraft seat materials.

  3. Department of Defense Advisory Group on Electron Devices. Special Technology Area Review on Microwave Packaging Technology. Appendix

    DTIC Science & Technology

    1993-02-01

    sintered in hydrogen furnace at very high temperatures . Multiple furnace firing occurs until the binders are removed and part density is achieved "* Process...and base Low temperature co-fired ceramic - Metallized for shielding and grounding - Low resistance thick-film metallization - High thermal resistance...ESPECIALLY LOW TEMPERATURE COFIRED CERAMIC CERAMICS HIGH THERMAL CONDUCTIVITY,MATCHED GaAS AND SILICON SUBSTRATE MATERIALS I I,1Z#A,17Mr1 J, TI

  4. Predictions of fire behavior and resistance to control: for use with photo series for the ponderosa pine type, ponderosa pine and associated species type, and lodgepole pine type.

    Treesearch

    Franklin R. Ward; David V. Sandberg

    1981-01-01

    This publication presents tables on the behavior of fire and the resistance of fuels to control. The information is to be used with the publication, "Photo Series for Quantifying Forest Residues in the Ponderosa Pine Type, Ponderosa Pine and Associated Species Type, Lodgepole Pine Type" (Maxwell, Wayne G.; Ward, Franklin R. 1976. Gen. Tech. Rep. PNW-GTR-052....

  5. Defense Infrastructure: DOD’s 2013 Facilities Corrosion Study Addressed Reporting Elements

    DTIC Science & Technology

    2014-03-27

    the coating system to metal structures helped prevent corrosion and provided resistance to fire . For the second element, to review a sampling of...noted, was to apply an epoxy coating system to metal structures to prevent corrosion and provide fire resistance. In 2006, DOD applied an epoxy... heat exchange  Fuel distribution  Plumbing  Bridge  Fuel storage  Roof  Building exterior—paint  Generator  Signage  Compressor  Hot water

  6. Predictions of fire behavior and resistance to control: for use with photo series for the sierra mixed conifer type and the sierra true fir type.

    Treesearch

    Franklin R. Ward; David V. Sandberg

    1981-01-01

    This publication presents tables on the behavior of fire and the resistance: of fuels to control. The information is to be used with the photos in the publication, "Photo Series for Quantifying Forest Residues in the Sierra Mixed Conifer Type, Sierra True Fir Type" (Maxwell, Wayne G.; Ward, Franklin R. 1979. Gen. Tech. Rep. PNW-GTR-095. Portland, OR: U.S....

  7. Flexible, High-Wettability and Fire-Resistant Separators Based on Hydroxyapatite Nanowires for Advanced Lithium-Ion Batteries.

    PubMed

    Li, Heng; Wu, Dabei; Wu, Jin; Dong, Li-Ying; Zhu, Ying-Jie; Hu, Xianluo

    2017-11-01

    Separators play a pivotal role in the electrochemical performance and safety of lithium-ion batteries (LIBs). The commercial microporous polyolefin-based separators often suffer from inferior electrolyte wettability, low thermal stability, and severe safety concerns. Herein, a novel kind of highly flexible and porous separator based on hydroxyapatite nanowires (HAP NWs) with excellent thermal stability, fire resistance, and superior electrolyte wettability is reported. A hierarchical cross-linked network structure forms between HAP NWs and cellulose fibers (CFs) via hybridization, which endows the separator with high flexibility and robust mechanical strength. The high thermal stability of HAP NW networks enables the separator to preserve its structural integrity at temperatures as high as 700 °C, and the fire-resistant property of HAP NWs ensures high safety of the battery. In particular, benefiting from its unique composition and highly porous structure, the as-prepared HAP/CF separator exhibits near zero contact angle with the liquid electrolyte and high electrolyte uptake of 253%, indicating superior electrolyte wettability compared with the commercial polyolefin separator. The as-prepared HAP/CF separator has unique advantages of superior electrolyte wettability, mechanical robustness, high thermal stability, and fire resistance, thus, is promising as a new kind of separator for advanced LIBs with enhanced performance and high safety. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Engineering an Undergarment for Flash/Flame Protection

    DTIC Science & Technology

    2011-11-01

    the event of a flash fire situation because the fabric could melt and stick to the Soldier’s skin causing more severe burn injury. Additionally, an...harm’s way which include fire fighters and police in their daily work. 1.1 Problem Statement The threat of burn injuries to Soldiers in combat due...to blasts, flash fires and secondary fires has resulted in the development of the Flame Resistant Army Combat Uniform, FR ACU. The FR ACUs provide

  9. A study on metallic thermal protection system panel for Reusable Launch Vehicle

    NASA Astrophysics Data System (ADS)

    Caogen, Yao; Hongjun, Lü; Zhonghua, Jia; Xinchao, Jia; Yan, Lu; Haigang, Li

    2008-07-01

    A Ni-based superalloy honeycomb thermal protection system (TPS) panel has been fabricated. And a curved Ni-based superalloy honeycomb sandwich has also been fabricated. The preliminary thermal insulation results of a fabricated Ni-based superalloy honeycomb TPS panel (the areal density of this panel is 6.7 kg /m2 and total height is 32 mm) indicate that the maximum temperature of the lower surfaces of the panel is lower than 150∘ C when the temperature of outer surface is held at 650∘ C for 30 min. The flatwise tensile strength and compressive properties of a fabricated Ni-based superalloy honeycomb sandwich coupon was studied at room temperature. A multilayered coating has been developed on the surface of the superalloy honeycomb TPS panel for environmental protection and thermal control. The oxidation weight-change results show that the weight change of the Ni-based superalloy honeycomb sandwich with the oxidation resistant coating is extremely small at 1100∘ C in air for 10 h. The emittance layer of the multilayered coating imparts an emittance in excess of 0.85 during exposure at 850∘ C, which was at least 14% greater than that of the substrate with oxidation resistant alone.

  10. Pre-stressed thermal protection systems

    NASA Technical Reports Server (NTRS)

    Dunn, T. J. (Inventor)

    1984-01-01

    A hexagonal protective and high temperature resistant system for the Space Shuttle Orbiter consists of a multiplicity of pockets formed by hexagonally oriented spacer bars secured on the vehicle substructure. A packing of low density insulating batt material 18 in each pocket, and a thin protective panel of laterally resilient advanced carbon-carbon material surmounting the peripherals bars and packing. Each panel has three stepped or offset lips on contiguous edges. At the center of each pocket is a fully insulated stanchion secured to and connecting the substructure and panel for flexing the panel toward the substructure and thereby prestressing the panel and forcing the panel edges firmly against the spacer bars.

  11. 75 FR 68688 - Airworthiness Directives; The Boeing Company Model 757 Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-09

    ...We are adopting a new airworthiness directive (AD) for all Model 757 airplanes. This AD requires changing the lower fixed leading edge panel assemblies immediately outboard of the nacelles at slats 4 and 7. This AD results from reports of Model 757 airplanes in service that have drain holes and unsealed panel assemblies in the fixed leading edge adjacent to the inboard end of slats 4 and 7 that are too close to the hot portion of the engines. We are issuing this AD to prevent fuel leaking onto an engine and a consequent fire.

  12. Comparison of Cepheid Xpert Flu/RSV XC and BioFire FilmArray for Detection of Influenza A, Influenza B, and Respiratory Syncytial Virus.

    PubMed

    Wahrenbrock, Mark G; Matushek, Scott; Boonlayangoor, Sue; Tesic, Vera; Beavis, Kathleen G; Charnot-Katsikas, Angella

    2016-07-01

    The Xpert Flu/RSV XC was compared to the FilmArray respiratory panel for detection of influenza (Flu) A, Flu B, and respiratory syncytial virus (RSV), using 128 nasopharyngeal swabs. Positive agreements were 100% for Flu A and RSV and 92.3% for Flu B. The Xpert may be useful in clinical situations when extensive testing is not required and may serve an important role in laboratories already performing broader respiratory panel testing. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  13. Failure of Quality Control Measures To Prevent Reporting of False Resistance to Imipenem, Resulting in a Pseudo-Outbreak of Imipenem-Resistant Pseudomonas aeruginosa

    PubMed Central

    Carmeli, Yehuda; Eichelberger, Karen; Soja, Don; Dakos, Joanna; Venkataraman, Lata; DeGirolami, Paola; Samore, Matthew

    1998-01-01

    False results showing an outbreak of Pseudomonas aeruginosa with resistance to imipenem were traced to a defective lot of microdilution MIC testing panels. These panels contained two- to threefold lower concentrations of imipenem than expected and resulted in artifactual two- to fourfold increases in MICs of imipenem. The quality-control MIC results for Pseudomonas aeruginosa ATCC 27853 were 4 μg/ml, the highest value within the range recommended by the National Committee for Clinical Laboratory Standards. We recommend that this value be considered out of the quality-control range. PMID:9466787

  14. Strength and Stiffness Analysis by the Finite-Difference Method of a Concrete Floor Slab Reinforced with Composite Rods During a Fire

    NASA Astrophysics Data System (ADS)

    Shirko, A. V.; Kamlyuk, A. N.; Drobysh, A. S.; Spiglazov, A. V.

    2017-05-01

    A strength and stiffness comparative analysis has been made of a concrete slab reinforced with composite-reinforcement rods and a slab reinforced with steel rods. The stress-strain state has been assessed for both versions of reinforcement of the slab. The stress-strain state was determined under the action of only static load and with subsequent application of temperature fields, i.e., under standard-fire conditions. It has been shown that the fire resistance of the slab with a composite reinforcement turns out to be 1.6 higher as far as the bearing capacity is concerned, than the fire resistance of the slab with a steel reinforcement, although the initial deflection due to the action of only static load for the slab reinforced with composite rods exceeds six to seven times the deflection of the slab reinforced with steel rods.

  15. Fire extinguishing tests -80 with methyl alcohol gasoline

    NASA Astrophysics Data System (ADS)

    Holmstedt, G.; Ryderman, A.; Carlsson, B.; Lennmalm, B.

    1980-10-01

    Large scale tests and laboratory experiments were carried out for estimating the extinguishing effectiveness of three alcohol resistant aqueous film forming foams (AFFF), two alcohol resistant fluoroprotein foams and two detergent foams in various poolfires: gasoline, isopropyl alcohol, acetone, methyl-ethyl ketone, methyl alcohol and M15 (a gasoline, methyl alcohol, isobutene mixture). The scaling down of large scale tests for developing a reliable laboratory method was especially examined. The tests were performed with semidirect foam application, in pools of 50, 11, 4, 0.6, and 0.25 sq m. Burning time, temperature distribution in the liquid, and thermal radiation were determined. An M15 fire can be extinguished with a detergent foam, but it is impossible to extinguish fires in polar solvents, such as methyl alcohol, acetone, and isopropyl alcohol with detergent foams, AFFF give the best results; and performances with small pools can hardly be correlated with results from large scale fires.

  16. Earth Observation taken during the Expedition 36 mission

    NASA Image and Video Library

    2013-08-24

    ISS036-E-035685 (24 Aug. 2013) --- One of the Expedition 36 crew members aboard the International Space Station used a 50mm lens to record this high oblique view of the massive drought-aided Rim Fire in and around California's Yosemite National Park and the Stanislaus National Forest on Aug. 24. A portion of a solar array panel on the orbital outpost can be seen in upper left corner of the image. Editor's Note: The fire began on Aug. 17 and, as of Aug. 26, continues to burn. More than 224 square miles have been affected.

  17. KSC-08pd1093

    NASA Image and Video Library

    2008-05-01

    CAPE CANAVERAL, Fla. -- In Firing Room No. 1 in the Launch Control Center at NASA's Kennedy Space Center, a worker maneuvers a panel to build another cabinet to hold equipment that will support the future Ares rocket launches as part of the Constellation Program. Future astronauts will ride to orbit on Ares I, which uses a single five-segment solid rocket booster, a derivative of the space shuttle's solid rocket booster, for the first stage. Ares will be launched from Pad 39B, which is being reconfigured from supporting space shuttle launches. The Launch Control Center firing rooms face the launch pads. Photo credit: NASA/Kim Shiflett

  18. Training Effectiveness Study of Simulator Usage and Its Impact on Live Fire Armor Gunnery

    DTIC Science & Technology

    2014-06-01

    including artillery  Round loading and reloading sounds  Loader’s “UP”  Main gun , M240, and M2 machine gun firing  Track clatter  Engine and...functional  TC’s hatch will not open  M2 machine gun is not replicated on the AGTS  Not all circuit breakers are supported from the display panels 18...Driver’s and loader’s stations are not simulated Of the limitations listed above, three are of most concern: the lack of M2 machine gun

  19. Integrated Target Acquisition and Fire Control Systems: Avionics Panel Symposium Held in Ottawa, Canada on 7-10 October 1991 (Systemes Integres d’Acquisition d’Objectifs et de Conduite de Tir)

    DTIC Science & Technology

    1992-02-01

    Designation with the CL-227 Sea Sentinel 31 byH SotadS.Joes SESSION V - LONGER TERM SYSTEMS Avionic System Improvement Proposal for the TORNADO...18’s fire control capability to deliver some types of smart munitions. Yet we also noted that while we lacked the target designators and control...source of lines came qystems designed to deny the information about the tactical enemy the use of height. Sophisticated situation they are facing. Enemy

  20. Audit Report, "Fire Protection Deficiencies at Los Alamos National Laboratory"

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2009-06-01

    The Department of Energy's Los Alamos National Laboratory (Los Alamos) maintains some of the Nation's most important national security assets, including nuclear materials. Many of Los Alamos' facilities are located in close proximity to one another, are occupied by large numbers of contract and Federal employees, and support activities ranging from nuclear weapons design to science-related activities. Safeguarding against fires, regardless of origin, is essential to protecting employees, surrounding communities, and national security assets. On June 1, 2006, Los Alamos National Security, LLC (LANS), became the managing and operating contractor for Los Alamos, under contract with the Department's National Nuclearmore » Security Administration (NNSA). In preparation for assuming its management responsibilities at Los Alamos, LANS conducted walk-downs of the Laboratory's facilities to identify pre-existing deficiencies that could give rise to liability, obligation, loss or damage. The walk-downs, which identified 812 pre-existing fire protection deficiencies, were conducted by subject matter professionals, including fire protection experts. While the Los Alamos Site Office has overall responsibility for the effectiveness of the fire protection program, LANS, as the Laboratory's operating contractor, has a major, day-to-day role in minimizing fire-related risks. The issue of fire protection at Los Alamos is more than theoretical. In May 2000, the 'Cerro Grande' fire burned about 43,000 acres, including 7,700 acres of Laboratory property. Due to the risk posed by fire to the Laboratory's facilities, workforce, and surrounding communities, we initiated this audit to determine whether pre-existing fire protection deficiencies had been addressed. Our review disclosed that LANS had not resolved many of the fire protection deficiencies that had been identified in early 2006: (1) Of the 296 pre-existing deficiencies we selected for audit, 174 (59 percent) had not been corrected; and, (2) A substantial portion of the uncorrected deficiencies, 86 (49 percent) were considered by the walk-down teams to be significant enough to warrant compensatory actions until the deficiency was corrected or was tracked to closure through implementation of corrective actions. Further, we found that 32 of the significant deficiencies had been closed by the previous Los Alamos contractor, prior to LANS assuming responsibility for operation of the Laboratory, even though the deficiencies had not been corrected. A fire protection expert provided technical support during the audit. As an example of uncorrected problems, LANS had not resolved, by performing periodic tests, a deficiency identified in 2006 regarding a kitchen hood fire suppression system in a facility located within the Los Alamos Neutron Science Center. Such systems are required to be tested twice a year by the National Fire Protection Association standard, a standard that had been adopted by Department of Energy under DOE Order 420.1B. Yet, in 2006, the LANS walk-down team recognized that this system had not been inspected since May 2004 and noted that deficient suppression systems could result in significantly high levels of property damage and loss. After we brought this issue to management's attention on February 6, 2009, LANS officials stated that the Laboratory would correct this deficiency. As with the problems involving the fire suppression system, we observed that LANS had not always corrected life safety deficiencies involving building exits at one of its primary facilities. This included providing a secondary emergency exit for a building with occupants on multiple floor levels. LANS had removed personnel from the third floor and improved the sprinkler system of the facility, but it had still not provided a secondary exit for personnel on the second floor by the time we completed our review. NNSA has since stated that this fire protection issue will be completely addressed by relocating personnel from the second floor. Perhaps most serious, our testing revealed that a number of deficiencies were formally closed even though actual corrective action had not been completed. Notably, we observed that action had not been taken to resolve a recommendation to replace a fire alarm panel found to be unreliable. After the walk-down was conducted but prior to contract transition, the former contractor closed the recommendation in its action tracking database even though the panel had not been replaced. The walk-down team had categorized the fire alarm system as requiring replacement since it had been modified many times, was old and obsolete, and had very limited available spare parts. In fact, the walk-down team concluded that the panel 'must be considered to be unreliable and should have a very high priority for replacement'.« less

  1. Small-diameter timber alchemy: can utilization pay the way toward fire-resistant forests

    Treesearch

    Jeremy S. Fried; R. Jamie Barbour; Roger D. Fight; Glenn Christensen; Guy Pinjuv

    2008-01-01

    There is growing interest in using biomass removed from hazardous fuels reduction treatments in wood-fired electrical generation facilities. An application of FIA BioSum to southwest Oregon’s Klamath ecoregion assessed the financial feasibility of fuel treatment and biomass generation under a range of product prices and fire hazard-motivated silvicultural prescriptions...

  2. The concept: Restoring ecological structure and process in ponderosa pine forests

    Treesearch

    Stephen F. Arno

    1996-01-01

    Elimination of the historic pattern of frequent low-intensity fires in ponderosa pine and pine-mixed conifer forests has resulted in major ecological disruptions. Prior to 1900, open stands of large, long-lived, fire-resistant ponderosa pine were typical. These were accompanied in some areas by other fire-dependent species such as western larch. Today, as a result of...

  3. KSC-00pp0516

    NASA Image and Video Library

    2000-03-30

    KENNEDY SPACE CENTER, FLA. -- A NASA helicopter releases 324 gallons of water onto a building in a simulated fire control demonstration. The high-impact-resistant flexible plastic bucket will be used for fire protection on property and buildings at Kennedy Space Center. Known as the "Bambi" bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.

  4. New fire-fighting water bucket releases its load for a demonstration.

    NASA Technical Reports Server (NTRS)

    2000-01-01

    A NASA helicopter releases the contents of the high-impact- resistant flexible plastic bucket it holds. The 324-gallon container will be used for fire protection on property and buildings at Kennedy Space Center. Known as the 'Bambi' bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.

  5. KSC00pp0516

    NASA Image and Video Library

    2000-03-30

    KENNEDY SPACE CENTER, FLA. -- A NASA helicopter releases 324 gallons of water onto a building in a simulated fire control demonstration. The high-impact-resistant flexible plastic bucket will be used for fire protection on property and buildings at Kennedy Space Center. Known as the "Bambi" bucket, it will also support the Fish and Wildlife Service for controlled burns plus any wild fires in the area.

  6. Influences of prior wildfires on vegetation response to subsequent fire in a reburned Southwestern landscape.

    PubMed

    Coop, Jonathan D; Parks, Sean A; McClernan, Sarah R; Holsinger, Lisa M

    2016-03-01

    Large and severe wildfires have raised concerns about the future of forested landscapes in the southwestern United States, especially under repeated burning. In 2011, under extreme weather and drought conditions, the Las Conchas fire burned over several previous burns as well as forests not recently exposed to fire. Our purpose was to examine the influences of prior wildfires on plant community composition and structure, subsequent burn severity, and vegetation response. To assess these relationships, we used satellite-derived measures of burn severity and a nonmetric multidimensional scaling of pre- and post- Las Conchas field samples. Earlier burns were associated with shifts from forested sites to open savannas and meadows, oak scrub, and ruderal communities. These non-forested vegetation types exhibited both resistance to subsequent fire, measured by reduced burn severity, and resilience to reburning, measured by vegetation recovery relative to forests not exposed to recent prior fire. Previous shifts toward non-forested states were strongly reinforced by reburning. Ongoing losses of forests and their ecological values confirm the need for restoration interventions. However, given future wildfire and climate projections, there may also be opportunities presented by transformations toward fire-resistant and resilient vegetation types within portions of the landscape.

  7. Fatigue Characterization of Fire Resistant Syntactic Foam Core Material

    NASA Astrophysics Data System (ADS)

    Hossain, Mohammad Mynul

    Eco-Core is a fire resistant material for sandwich structural application; it was developed at NC A&T State University. The Eco-Core is made of very small amount of phenolic resin and large volume of flyash by a syntactic process. The process development, static mechanical and fracture, fire and toxicity safety and water absorption properties and the design of sandwich structural panels with Eco-Core material was established and published in the literature. One of the important properties that is needed for application in transportation vehicles is the fatigue performance under different stress states. Fatigue data are not available even for general syntactic foams. The objective of this research is to investigate the fatigue performance of Eco-Core under three types of stress states, namely, cyclic compression, shear and flexure, then document failure modes, and develop empherical equations for predicting fatigue life of Eco-Core under three stress states. Compression-Compression fatigue was performed directly on Eco-Core cylindrical specimen, whereas shear and flexure fatigue tests were performed using sandwich beam made of E glass-Vinyl Ester face sheet and Eco-Core material. Compression-compression fatigue test study was conducted at two values of stress ratios (R=10 and 5), for the maximum compression stress (sigmamin) range of 60% to 90% of compression strength (sigmac = 19.6 +/- 0.25 MPa) for R=10 and 95% to 80% of compression strength for R=5. The failure modes were characterized by the material compliance change: On-set (2% compliance change), propagation (5%) and ultimate failure (7%). The number of load cycles correspond to each of these three damages were characterized as on-set, propagation and total lives. A similar approach was used in shear and flexure fatigue tests with stress ratio of R=0.1. The fatigue stress-number of load cycles data followed the standard power law equation for all three stress states. The constant of the equation were established for the three stress states and three types of the failure modes. This equation was used to estimate endurance limit (106 cycles) of the material. Like metallic materials, the compression fatigue life of Eco-Core was found to be dependent on the stress range instead of maximum or mean cyclic stress. Furthermore shear and flexural ultimate failure of the core material was found to be due to a combination of shear and tensile stress.

  8. Fire Safety in the Low-Gravity Spacecraft Environment

    NASA Technical Reports Server (NTRS)

    Friedman, Robert

    1999-01-01

    Research in microgravity (low-gravity) combustion promises innovations and improvements in fire prevention and response for human-crew spacecraft. Findings indicate that material flammability and fire spread in microgravity are significantly affected by atmospheric flow rate, oxygen concentration, and diluent composition. This information can lead to modifications and correlations to standard material-assessment tests for prediction of fire resistance in space. Research on smoke-particle changes in microgravity promises future improvements and increased sensitivity of smoke detectors in spacecraft. Research on fire suppression by extinguishing agents and venting can yield new information on effective control of the rare, but serious fire events in spacecraft.

  9. Hepatitis C virus resistance to broadly neutralizing antibodies measured using replication-competent virus and pseudoparticles

    PubMed Central

    Wasilewski, Lisa N.; Ray, Stuart C.

    2016-01-01

    A better understanding of natural variation in neutralization resistance and fitness of diverse hepatitis C virus (HCV) envelope (E1E2) variants will be critical to guide rational development of an HCV vaccine. This work has been hindered by inadequate genetic diversity in viral panels and by a lack of standardization of HCV entry assays. Neutralization assays generally use lentiviral pseudoparticles expressing HCV envelope proteins (HCVpp) or chimeric full-length viruses that are replication competent in cell culture (HCVcc). There have been few systematic comparisons of specific infectivities of E1E2-matched HCVcc and HCVpp, and to our knowledge, neutralization of E1E2-matched HCVpp and HCVcc has never been compared using a diverse panel of human broadly neutralizing monoclonal antibodies (bNAbs) targeting distinct epitopes. Here, we describe an efficient method for introduction of naturally occurring E1E2 genes into a full-length HCV genome, producing replication-competent chimeric HCVcc. We generated diverse panels of E1E2-matched HCVcc and HCVpp and measured the entry-mediating fitness of E1E2 variants using the two systems. We also compared neutralization of E1E2-matched HCVcc and HCVpp by a diverse panel of human bNAbs targeting epitopes across E1E2. We found no correlation between specific infectivities of E1E2-matched HCVcc versus HCVpp, but found a very strong positive correlation between relative neutralization resistance of these same E1E2-matched HCVcc and HCVpp variants. These results suggest that quantitative comparisons of neutralization resistance of E1E2 variants can be made with confidence using either HCVcc or HCVpp, allowing the use of either or both systems to maximize diversity of neutralization panels. PMID:27667373

  10. Hepatitis C virus resistance to broadly neutralizing antibodies measured using replication-competent virus and pseudoparticles.

    PubMed

    Wasilewski, Lisa N; Ray, Stuart C; Bailey, Justin R

    2016-11-01

    A better understanding of natural variation in neutralization resistance and fitness of diverse hepatitis C virus (HCV) envelope (E1E2) variants will be critical to guide rational development of an HCV vaccine. This work has been hindered by inadequate genetic diversity in viral panels and by a lack of standardization of HCV entry assays. Neutralization assays generally use lentiviral pseudoparticles expressing HCV envelope proteins (HCVpp) or chimeric full-length viruses that are replication competent in cell culture (HCVcc). There have been few systematic comparisons of specific infectivities of E1E2-matched HCVcc and HCVpp, and to our knowledge, neutralization of E1E2-matched HCVpp and HCVcc has never been compared using a diverse panel of human broadly neutralizing monoclonal antibodies (bNAbs) targeting distinct epitopes. Here, we describe an efficient method for introduction of naturally occurring E1E2 genes into a full-length HCV genome, producing replication-competent chimeric HCVcc. We generated diverse panels of E1E2-matched HCVcc and HCVpp and measured the entry-mediating fitness of E1E2 variants using the two systems. We also compared neutralization of E1E2-matched HCVcc and HCVpp by a diverse panel of human bNAbs targeting epitopes across E1E2. We found no correlation between specific infectivities of E1E2-matched HCVcc versus HCVpp, but found a very strong positive correlation between relative neutralization resistance of these same E1E2-matched HCVcc and HCVpp variants. These results suggest that quantitative comparisons of neutralization resistance of E1E2 variants can be made with confidence using either HCVcc or HCVpp, allowing the use of either or both systems to maximize diversity of neutralization panels.

  11. 30 CFR 75.1107-1 - Fire-resistant hydraulic fluids and fire suppression devices on underground equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... requirements of §§ 75.1107-3 through 75.1107-16. (3) Unattended enclosed motors, controls, transformers... surface, platform, or equivalent. The electrical cables at such equipment shall conform with the...

  12. Termites Are Resistant to the Effects of Fire at Multiple Spatial Scales.

    PubMed

    Avitabile, Sarah C; Nimmo, Dale G; Bennett, Andrew F; Clarke, Michael F

    2015-01-01

    Termites play an important ecological role in many ecosystems, particularly in nutrient-poor arid and semi-arid environments. We examined the distribution and occurrence of termites in the fire-prone, semi-arid mallee region of south-eastern Australia. In addition to periodic large wildfires, land managers use fire as a tool to achieve both asset protection and ecological outcomes in this region. Twelve taxa of termites were detected by using systematic searches and grids of cellulose baits at 560 sites, clustered in 28 landscapes selected to represent different fire mosaic patterns. There was no evidence of a significant relationship between the occurrence of termite species and time-since-fire at the site scale. Rather, the occurrence of species was related to habitat features such as the density of mallee trees and large logs (>10 cm diameter). Species richness was greater in chenopod mallee vegetation on heavier soils in swales, rather than Triodia mallee vegetation of the sandy dune slopes. At the landscape scale, there was little evidence that the frequency of occurrence of termite species was related to fire, and no evidence that habitat heterogeneity generated by fire influenced termite species richness. The most influential factor at the landscape scale was the environmental gradient represented by average annual rainfall. Although termites may be associated with flammable habitat components (e.g. dead wood), they appear to be buffered from the effects of fire by behavioural traits, including nesting underground, and the continued availability of dead wood after fire. There is no evidence to support the hypothesis that a fine-scale, diverse mosaic of post-fire age-classes will enhance the diversity of termites. Rather, termites appear to be resistant to the effects of fire at multiple spatial scales.

  13. Termites Are Resistant to the Effects of Fire at Multiple Spatial Scales

    PubMed Central

    Avitabile, Sarah C.; Nimmo, Dale G.; Bennett, Andrew F.; Clarke, Michael F.

    2015-01-01

    Termites play an important ecological role in many ecosystems, particularly in nutrient-poor arid and semi-arid environments. We examined the distribution and occurrence of termites in the fire-prone, semi-arid mallee region of south-eastern Australia. In addition to periodic large wildfires, land managers use fire as a tool to achieve both asset protection and ecological outcomes in this region. Twelve taxa of termites were detected by using systematic searches and grids of cellulose baits at 560 sites, clustered in 28 landscapes selected to represent different fire mosaic patterns. There was no evidence of a significant relationship between the occurrence of termite species and time-since-fire at the site scale. Rather, the occurrence of species was related to habitat features such as the density of mallee trees and large logs (>10 cm diameter). Species richness was greater in chenopod mallee vegetation on heavier soils in swales, rather than Triodia mallee vegetation of the sandy dune slopes. At the landscape scale, there was little evidence that the frequency of occurrence of termite species was related to fire, and no evidence that habitat heterogeneity generated by fire influenced termite species richness. The most influential factor at the landscape scale was the environmental gradient represented by average annual rainfall. Although termites may be associated with flammable habitat components (e.g. dead wood), they appear to be buffered from the effects of fire by behavioural traits, including nesting underground, and the continued availability of dead wood after fire. There is no evidence to support the hypothesis that a fine-scale, diverse mosaic of post-fire age-classes will enhance the diversity of termites. Rather, termites appear to be resistant to the effects of fire at multiple spatial scales. PMID:26571383

  14. The Effect of Diet and Opponent Size on Aggressive Interactions Involving Caribbean Crazy Ants (Nylanderia fulva)

    PubMed Central

    Horn, Katherine C.; Eubanks, Micky D.; Siemann, Evan

    2013-01-01

    Biotic interactions are often important in the establishment and spread of invasive species. In particular, competition between introduced and native species can strongly influence the distribution and spread of exotic species and in some cases competition among introduced species can be important. The Caribbean crazy ant, Nylanderia fulva, was recently introduced to the Gulf Coast of Texas, and appears to be spreading inland. It has been hypothesized that competition with the red imported fire ant, Solenopsis invicta, may be an important factor in the spread of crazy ants. We investigated the potential of interspecific competition among these two introduced ants by measuring interspecific aggression between Caribbean crazy ant workers and workers of Solenopsis invicta. Specifically, we examined the effect of body size and diet on individual-level aggressive interactions among crazy ant workers and fire ants. We found that differences in diet did not alter interactions between crazy ant workers from different nests, but carbohydrate level did play an important role in antagonistic interactions with fire ants: crazy ants on low sugar diets were more aggressive and less likely to be killed in aggressive encounters with fire ants. We found that large fire ants engaged in fewer fights with crazy ants than small fire ants, but fire ant size affected neither fire ant nor crazy ant mortality. Overall, crazy ants experienced higher mortality than fire ants after aggressive encounters. Our findings suggest that fire ant workers might outcompete crazy ant workers on an individual level, providing some biotic resistance to crazy ant range expansion. However, this resistance may be overcome by crazy ants that have a restricted sugar intake, which may occur when crazy ants are excluded from resources by fire ants. PMID:23776702

  15. Repetitive Series Interrupter II.

    DTIC Science & Technology

    1977-07-01

    nated by other authorized documents. The citation of trade names and names of manufacturers is this report is not to be construed as official... intergrating inductor Magnet circuit load resistance Pulse-forming network load resistance Fault network load resistance Time delay between TUT fire and

  16. Overview of safety research

    NASA Technical Reports Server (NTRS)

    Enders, J. H.

    1978-01-01

    Aircraft safety is reviewed by first establishing a perspective of air transportation accidents as a function of calendar year, geographic area, and phase of flight, and then by describing the threats to safety and NASA research underway in the three representative areas of engine operational problems, meteorological phenomena, and fire. Engine rotor burst protection, aircraft nacelle fire extinguishment, the aircraft-weather interface, severe weather wind shears and turbulence, clear air turbulence, and lightning are among the topics covered. Fire impact management through fire resistant materials technology development is emphasized.

  17. Resistance after firing protected electric match. [Patent application

    DOEpatents

    Montoya, A.P.

    1980-03-20

    An electric match having electrical leads embedded in flame-producing compound is protected against an accidental resistance across the leads after firing by a length of heat-shrinkable tubing encircling the match body and having a skirt portion extending beyond the leads. The heat of the burning match and an adjacent thermal battery causes the tubing to fold over the end of the match body, covering the ends of the leads and protecting them from molten pieces of the battery.

  18. Maleimido substituted cyclotriphosphazene resins for fire and heat resistant composites

    NASA Technical Reports Server (NTRS)

    Kumar, D.; Fohlen, G. M.; Parker, J. A.

    1983-01-01

    A new class of fire- and heat-resistant matrix resins have been synthesized by the thermal polymerization of maleimido substituted phenoxycyclotriphosphazenes. The resins have exhibited a char yield of 82 percent at 800 C in nitrogen and 81 percent at 700 C in air. Graphite-fabric laminates based on a resin of this class have shown a limiting oxygen index of 100 percent even at 300 C. Details of the fabrication of the resins and the composites and testing procedures are discussed.

  19. Predictions of fire behavior and resistance to control: for use with photo series for the Douglas fir-hemlock type and the coastal Douglas-fir-hardwood type.

    Treesearch

    David V. SANDBERG; Franklin R. Ward

    1981-01-01

    This publication presents tables on the behavior of fire and the resistance of fuels to control. The information is to be used with the photos in the publication, "Photo Series for Quantifying Forest Residues in the Coastal Douglas-fir—Hemlock Type, Coastal Douglas-fir—Hardwood Type" (Maxwell, Wayne G.; Ward, Franklin R. 1976. Gen. Tech. Rep. PNW-GTR-051....

  20. New Approaches to Maximizing Thermo-oxidation Resistance of Polycyanurate Networks

    DTIC Science & Technology

    2014-08-13

    Resveratrol -based CE Delivers Exceptional Thermal Stability and Fire Resistance Acknowledgements: Strategic Environmental Research and Development...CH2-CH2- (dihydro resveratrol ) OH OH HO R OCN OCN NCO R Char (65%) Cure at 250C N N N N N N O O O R N N N Resveratrol cyanate ester* Resveratrol ...triazine thermoset resin > 450C Fire ( resveratrol ) • Polyphenolic antioxidant used as a dietary supplement • Extracted from seaweed, red grapes, red wine

  1. Method for applying photographic resists to otherwise incompatible substrates

    NASA Technical Reports Server (NTRS)

    Fuhr, W. (Inventor)

    1981-01-01

    A method for applying photographic resists to otherwise incompatible substrates, such as a baking enamel paint surface, is described wherein the uncured enamel paint surface is coated with a non-curing lacquer which is, in turn, coated with a partially cured lacquer. The non-curing lacquer adheres to the enamel and a photo resist material satisfactorily adheres to the partially cured lacquer. Once normal photo etching techniques are employed the lacquer coats can be easily removed from the enamel leaving the photo etched image. In the case of edge lighted instrument panels, a coat of uncured enamel is placed over the cured enamel followed by the lacquer coats and the photo resists which is exposed and developed. Once the etched uncured enamel is cured, the lacquer coats are removed leaving an etched panel.

  2. Fire related hazards of cables: The Canadian position development of fire resistant inside wiring cable

    NASA Astrophysics Data System (ADS)

    Hartley, M. D.; Jaques, R. E.

    1986-11-01

    The Canadian Electrical Code and the National Building Code in Canada recognize only two designations in regards to fire resistance of cables; cables for use in combustible (residential) buildings and cables for use in non-combustible buildings. The Test standard for cables for non-combustible buildings resembles IEEE-383. However, it is more severe; particularly for small nonarmoured cables such as Inside Wiring Cable. This forthcoming requirement has necessitated material and product development. Although an Inside Wiring cable modification of both insulation and jacket was undertaken, the large volume fraction of combustible material in the jacket vis a vis the insulation made it the area of greatest impact. The paper outlines the development and its effect on cable performance.

  3. Multi-Material Front Contact for 19% Thin Film Solar Cells.

    PubMed

    van Deelen, Joop; Tezsevin, Yasemin; Barink, Marco

    2016-02-06

    The trade-off between transmittance and conductivity of the front contact material poses a bottleneck for thin film solar panels. Normally, the front contact material is a metal oxide and the optimal cell configuration and panel efficiency were determined for various band gap materials, representing Cu(In,Ga)Se₂ (CIGS), CdTe and high band gap perovskites. Supplementing the metal oxide with a metallic copper grid improves the performance of the front contact and aims to increase the efficiency. Various front contact designs with and without a metallic finger grid were calculated with a variation of the transparent conductive oxide (TCO) sheet resistance, scribing area, cell length, and finger dimensions. In addition, the contact resistance and illumination power were also assessed and the optimal thin film solar panel design was determined. Adding a metallic finger grid on a TCO gives a higher solar cell efficiency and this also enables longer cell lengths. However, contact resistance between the metal and the TCO material can reduce the efficiency benefit somewhat.

  4. Rubberized, Brominated Epoxies

    NASA Technical Reports Server (NTRS)

    Gilwee, W.; Kourtides, D.; Parker, J.; Nir, Z.

    1985-01-01

    Graphite/epoxy composite materials made with resins containing bromine and rubber additives. New composites tougher and more resistant to fire. Flame resistance increased by introducing bromine via commercial brominated flame-retartant polymeric additives.

  5. Conference on the Development of Fire-Resistant Aircraft Passenger Seats

    NASA Technical Reports Server (NTRS)

    Fewell, L. L.; Kourtides, D. A.; Rosser, R. W.; Parker, J. A.

    1976-01-01

    Papers are presented dealing with the development of aircraft seats with the minimum fire risk. Criteria examined include: flame spread, heat release, and smoke and/or toxic fumes. Materials and performance specifications of all seat material options are provided.

  6. The impact of land ownership, firefighting, and reserve status on fire probability in California

    NASA Astrophysics Data System (ADS)

    Starrs, Carlin Frances; Butsic, Van; Stephens, Connor; Stewart, William

    2018-03-01

    The extent of wildfires in the western United States is increasing, but how land ownership, firefighting, and reserve status influence fire probability is unclear. California serves as a unique natural experiment to estimate the impact of these factors, as ownership is split equally between federal and non-federal landowners; there is a relatively large proportion of reserved lands where extractive uses are prohibited and fire suppression is limited; and land ownership and firefighting responsibility are purposefully not always aligned. Panel Poisson regression techniques and pre-regression matching were used to model changes in annual fire probability from 1950-2015 on reserve and non-reserve lands on federal and non-federal ownerships across four vegetation types: forests, rangelands, shrublands, and forests without commercial species. Fire probability was found to have increased over time across all 32 categories. A marginal effects analysis showed that federal ownership and firefighting was associated with increased fire probability, and that the difference in fire probability on federal versus non-federal lands is increasing over time. Ownership, firefighting, and reserve status, played roughly equal roles in determining fire probability, and were found to have much greater influence than average maximum temperature (°C) during summer months (June, July, August), average annual precipitation (cm), and average annual topsoil moisture content by volume, demonstrating the critical role these factors play in western fire regimes and the importance of including them in future analysis focused on understanding and predicting wildfire in the Western United States.

  7. Charring rate of wood exposed to a constant heat flux

    Treesearch

    R. H. White; H. C. Tran

    1996-01-01

    A critical factor in the fire endurance of a wood member is its rate of charring. Most available charring rate data have been obtained using the time-temperature curves of the standard fire resistance tests (ASTM E 119 and ISO 834) to define the fire exposure. The increased use of heat release calorimeters using exposures of constant heat flux levels has broadened the...

  8. 77 FR 58035 - Protection of Stratospheric Ozone: Listing of Substitutes for Ozone-Depleting Substances-Fire...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-19

    .... The Agency has identified four possible decision categories for substitutes that are submitted for... Change 2007: The Physical Science Basis. Contribution of Working Group I to the Fourth Assessment Report of the Intergovernmental Panel on Climate Change [Solomon, S., D. Qin, M. Manning, Z. Chen, M...

  9. 77 FR 64696 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-23

    ... installing an unmodified wing panel on that airplane. Delta justified its request by stating that the lack of... following a ground fire incident and reports of flammable fluid leaks from the wing leading edge area onto... area of the wing. We are issuing this AD to prevent flammable fluid from leaking onto the engine...

  10. Influence of ZrO2 addition on the microstructure and discharge properties of Mg-Zr-O protective layers in alternating current plasma display panels

    NASA Astrophysics Data System (ADS)

    Guo, Bingang; Liu, Chunliang; Song, Zhongxiao; Liu, Liu; Fan, Yufeng; Xia, Xing; Fan, Duowang

    2005-08-01

    Mg-Zr-O protective layers for alternating current plasma display panels were deposited by e-beam evaporation. The effect of the ZrO2 addition on both the discharge properties [firing voltage Vf, minimum sustaining voltage Vs, and memory coefficient (MC)] and the microstructure of deposited Mg-Zr-O films were investigated. The results show that the film microstructure changes and the electron emission enhancement due to the ZrO2 addition are the main reasons for the improvements of the discharge properties of Mg-Zr-O films. A small amount of Zr solution in MgO under its solid solubility can effectively increase the outer-shell valence electron emission yield so as to decrease Vf and Vs compared with using a pure MgO protective layer. The ZrO2/(MgO +ZrO2) ratio has a great effect on the film surface conditions. Proper surface morphologies make a good contribution to obtain large MC in accordance with lower firing voltage.

  11. Full-scale flammability test data for validation of aircraft fire mathematical models

    NASA Technical Reports Server (NTRS)

    Kuminecz, J. F.; Bricker, R. W.

    1982-01-01

    Twenty-five large scale aircraft flammability tests were conducted in a Boeing 737 fuselage at the NASA Johnson Space Center (JSC). The objective of this test program was to provide a data base on the propagation of large scale aircraft fires to support the validation of aircraft fire mathematical models. Variables in the test program included cabin volume, amount of fuel, fuel pan area, fire location, airflow rate, and cabin materials. A number of tests were conducted with jet A-1 fuel only, while others were conducted with various Boeing 747 type cabin materials. These included urethane foam seats, passenger service units, stowage bins, and wall and ceiling panels. Two tests were also included using special urethane foam and polyimide foam seats. Tests were conducted with each cabin material individually, with various combinations of these materials, and finally, with all materials in the cabin. The data include information obtained from approximately 160 locations inside the fuselage.

  12. Rheology of Foam Near the Order-Disorder Phase Transition

    NASA Technical Reports Server (NTRS)

    Holt, R. Glynn; McDaniel, J. Gregory

    1999-01-01

    Foams are extremely important in a variety of industrial applications. Foams are widely used in fire-fighting applications, and are especially effective in fighting flammable liquid fires. In fact the Fire Suppression System aboard the Space Shuttle utilizes cylinders of Halon foam, which, when fired, force a rapidly expanding foam into the convoluted spaces behind instrument panels. Foams are critical in the process of enhanced oil recovery, due to their surface-active and highly viscous nature. They are also used as drilling fluids in underpressurized geologic formations. They are used as transport agents, and as trapping agents. They are also used as separation agents, where ore refinement is accomplished by froth flotation of the typically lighter and hydrophobic contaminants. The goal of the proposed investigation is the determination of the mechanical and rheological properties of foams, utilizing the microgravity environment to explore foam rheology for foams which cannot exist, or only exist for a short time, in 1g.

  13. Fabrics for fire resistant passenger seats in aircraft

    NASA Technical Reports Server (NTRS)

    Tesoro, G. C.

    1978-01-01

    The essential elements of the problem and of approaches to improved fire resistance in aircraft seats are reviewed. The performance requirements and availability of materials, delay in the ignition of upholstery fabric by a small source are considered a realistic objective. Results of experimental studies on the thermal response of fabrics and fabric/foam combinations suggest significant conclusions regarding: (1) the ignition behavior of a commercial 90/10 wool/nylon upholstery fabric relative to fabrics made from thermally stable polymers; (2) the role of the foam backing; (3) the behavior of seams. These results, coupled with data from other sources, also confirm the importance of materials' interactions in multicomponent assemblies, and the need for system testing prior to materials' selection. The use of an interlinear or thermal barrier between upholstery fabric and foam is a promising and viable approach to improved fire resistance of the seat assembly, but experimental evaluation of specific combinations of materials or systems is an essential part of the selection process.

  14. Evaluation of Blast Resistance of Fiber Reinforced Composite Specimens under Contact Blast Load

    NASA Astrophysics Data System (ADS)

    Janota, O.; Foglar, M.

    2017-09-01

    This paper presents results of experimental programme which took place in 2014, 2015 and 2016. Experiments were focused on the resistance of full scale concrete panels subjected to contact blast loading. Specimens were loaded by contact blast by plastic explosive. All specimens were reinforced concrete slabs made of fiber concrete. Basalt mesh and textile sheets were added to some of the experiments for creating more heterogeneous material to achieve better resistance of the specimens. Evaluation of experiments was mainly focused on the damaged area on the contact side and soffit of the specimens. Dependency of the final damage of concrete panels on the weight of explosive and concrete strength was assessed.

  15. Experimental determination of satellite bolted joints thermal resistance

    NASA Technical Reports Server (NTRS)

    Mantelli, Marcia Barbosa Henriques; Basto, Jose Edson

    1990-01-01

    The thermal resistance was experimentally determined of the bolted joints of the first Brazilian satellite (SCD 01). These joints, used to connect the satellite structural panels, are reproduced in an experimental apparatus, keeping, as much as possible, the actual dimensions and materials. A controlled amount of heat is forced to pass through the joint and the difference of temperature between the panels is measured. The tests are conducted in a vacuum chamber with liquid nitrogen cooled walls, that simulates the space environment. Experimental procedures are used to avoid much heat losses, which are carefully calculated. Important observations about the behavior of the joint thermal resistance with the variation of the mean temperature are made.

  16. Ballistic Resistance of Honeycomb Sandwich Panels under In-Plane High-Velocity Impact

    PubMed Central

    Yang, Shu; Wang, Dong; Yang, Li-Jun

    2013-01-01

    The dynamic responses of honeycomb sandwich panels (HSPs) subjected to in-plane projectile impact were studied by means of explicit nonlinear finite element simulations using LS-DYNA. The HSPs consisted of two identical aluminum alloy face-sheets and an aluminum honeycomb core featuring three types of unit cell configurations (regular, rectangular-shaped, and reentrant hexagons). The ballistic resistances of HSPs with the three core configurations were first analyzed. It was found that the HSP with the reentrant auxetic honeycomb core has the best ballistic resistance, due to the negative Poisson's ratio effect of the core. Parametric studies were then carried out to clarify the influences of both macroscopic (face-sheet and core thicknesses, core relative density) and mesoscopic (unit cell angle and size) parameters on the ballistic responses of the auxetic HSPs. Numerical results show that the perforation resistant capabilities of the auxetic HSPs increase as the values of the macroscopic parameters increase. However, the mesoscopic parameters show nonmonotonic effects on the panels' ballistic capacities. The empirical equations for projectile residual velocities were formulated in terms of impact velocity and the structural parameters. It was also found that the blunter projectiles result in higher ballistic limits of the auxetic HSPs. PMID:24187526

  17. Ballistic resistance of honeycomb sandwich panels under in-plane high-velocity impact.

    PubMed

    Qi, Chang; Yang, Shu; Wang, Dong; Yang, Li-Jun

    2013-01-01

    The dynamic responses of honeycomb sandwich panels (HSPs) subjected to in-plane projectile impact were studied by means of explicit nonlinear finite element simulations using LS-DYNA. The HSPs consisted of two identical aluminum alloy face-sheets and an aluminum honeycomb core featuring three types of unit cell configurations (regular, rectangular-shaped, and reentrant hexagons). The ballistic resistances of HSPs with the three core configurations were first analyzed. It was found that the HSP with the reentrant auxetic honeycomb core has the best ballistic resistance, due to the negative Poisson's ratio effect of the core. Parametric studies were then carried out to clarify the influences of both macroscopic (face-sheet and core thicknesses, core relative density) and mesoscopic (unit cell angle and size) parameters on the ballistic responses of the auxetic HSPs. Numerical results show that the perforation resistant capabilities of the auxetic HSPs increase as the values of the macroscopic parameters increase. However, the mesoscopic parameters show nonmonotonic effects on the panels' ballistic capacities. The empirical equations for projectile residual velocities were formulated in terms of impact velocity and the structural parameters. It was also found that the blunter projectiles result in higher ballistic limits of the auxetic HSPs.

  18. Closeup view of the Pilot's Seat on the Flight Deck ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Close-up view of the Pilot's Seat on the Flight Deck of the Orbiter Discovery. It appears the Orbiter is in the roll out / launch pad configuration. A protective cover is over the Rotational Hand Controller to protect it during the pilot's ingress. Control panels R1 and R2 are prominent in this view. Panel R1 has switches for control and maintenance of on-board cryogenics for the fuel cells among other functions and panel R2 has switches and controls for the Auxiliary Power Units, ET umbilical doors as well as other operational controls. Note the portable fire extinguisher in the lower right corner of the image. This photograph was taken at Kennedy Space Center. - Space Transportation System, Orbiter Discovery (OV-103), Lyndon B. Johnson Space Center, 2101 NASA Parkway, Houston, Harris County, TX

  19. A full-scale fire program to evaluate new furnishings and textile materials developed by the National Aeronautics and Space Administration

    NASA Technical Reports Server (NTRS)

    Hillenbrand, L. J.; Wray, J. A.

    1974-01-01

    A program of experimental fires was carried out to establish the advantages offered by new materials for improved fire safety. Four full-scale bedrooms, differing only in the materials used to furnish them, were built and burned to provide comparative data on the fire hazards produced. Cost and availability differences were not considered. The visual evidence provided by TV and photographic coverage of the four experimental room fires showed clearly that the rooms responded very differently to a common ignition condition. Resistance to the ignition and spread of fire was substantially improved in the rooms furnished completely or partially with the new materials.

  20. Differences in spike train variability in rat vasopressin and oxytocin neurons and their relationship to synaptic activity

    PubMed Central

    Li, Chunyan; Tripathi, Pradeep K; Armstrong, William E

    2007-01-01

    The firing pattern of magnocellular neurosecretory neurons is intimately related to hormone release, but the relative contribution of synaptic versus intrinsic factors to the temporal dispersion of spikes is unknown. In the present study, we examined the firing patterns of vasopressin (VP) and oxytocin (OT) supraoptic neurons in coronal slices from virgin female rats, with and without blockade of inhibitory and excitatory synaptic currents. Inhibitory postsynaptic currents (IPSCs) were twice as prevalent as their excitatory counterparts (EPSCs), and both were more prevalent in OT compared with VP neurons. Oxytocin neurons fired more slowly and irregularly than VP neurons near threshold. Blockade of Cl− currents (including tonic and synaptic currents) with picrotoxin reduced interspike interval (ISI) variability of continuously firing OT and VP neurons without altering input resistance or firing rate. Blockade of EPSCs did not affect firing pattern. Phasic bursting neurons (putative VP neurons) were inconsistently affected by broad synaptic blockade, suggesting that intrinsic factors may dominate the ISI distribution during this mode in the slice. Specific blockade of synaptic IPSCs with gabazine also reduced ISI variability, but only in OT neurons. In all cases, the effect of inhibitory blockade on firing pattern was independent of any consistent change in input resistance or firing rate. Since the great majority of IPSCs are randomly distributed, miniature events (mIPSCs) in the coronal slice, these findings imply that even mIPSCs can impart irregularity to the firing pattern of OT neurons in particular, and could be important in regulating spike patterning in vivo. For example, the increased firing variability that precedes bursting in OT neurons during lactation could be related to significant changes in synaptic activity. PMID:17332000

  1. Daily black carbon emissions from fires in northern Eurasia for 2002-2015

    NASA Astrophysics Data System (ADS)

    Hao, Wei Min; Petkov, Alexander; Nordgren, Bryce L.; Corley, Rachel E.; Silverstein, Robin P.; Urbanski, Shawn P.; Evangeliou, Nikolaos; Balkanski, Yves; Kinder, Bradley L.

    2016-12-01

    Black carbon (BC) emitted from fires in northern Eurasia is transported and deposited on ice and snow in the Arctic and can accelerate its melting during certain times of the year. Thus, we developed a high spatial resolution (500 m × 500 m) dataset to examine daily BC emissions from fires in this region for 2002-2015. Black carbon emissions were estimated based on MODIS (Moderate Resolution Imaging Spectroradiometer) land cover maps and detected burned areas, the Forest Inventory Survey of the Russian Federation, the International Panel on Climate Change (IPCC) Tier-1 Global Biomass Carbon Map for the year 2000, and vegetation specific BC emission factors. Annual BC emissions from northern Eurasian fires varied greatly, ranging from 0.39 Tg in 2010 to 1.82 Tg in 2015, with an average of 0.71 ± 0.37 Tg from 2002 to 2015. During the 14-year period, BC emissions from forest fires accounted for about two-thirds of the emissions, followed by grassland fires (18 %). Russia dominated the BC emissions from forest fires (92 %) and central and western Asia was the major region for BC emissions from grassland fires (54 %). Overall, Russia contributed 80 % of the total BC emissions from fires in northern Eurasia. Black carbon emissions were the highest in the years 2003, 2008, and 2012. Approximately 58 % of the BC emissions from fires occurred in spring, 31 % in summer, and 10 % in fall. The high emissions in spring also coincide with the most intense period of ice and snow melting in the Arctic.

  2. 14 CFR 25.1713 - Fire protection: EWIS.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Electrical Wiring Interconnection Systems (EWIS) § 25.1713... used during emergency procedures must be fire resistant. (c) Insulation on electrical wire and electrical cable, and materials used to provide additional protection for the wire and cable, installed in...

  3. Burn-Resistant, Strong Metal-Matrix Composites

    NASA Technical Reports Server (NTRS)

    Stoltzfus, Joel M.; Tayal, Moti J.

    2003-01-01

    Ceramic particulate fillers increase the specific strengths and burn resistances of metals: This is the conclusion drawn by researchers at Johnson Space Center's White Sands Test Facility. The researchers had theorized that the inclusion of ceramic particles in metal tools and other metal objects used in oxygen-rich atmospheres (e.g., in hyperbaric chambers and spacecraft) could reduce the risk of fire and the consequent injury or death of personnel. In such atmospheres, metal objects act as ignition sources, creating fire hazards. However, not all metals are equally hazardous: some are more burn-resistant than others are. It was the researchers purpose to identify a burn-resistant, high-specific-strength ceramic-particle/metal-matrix composite that could be used in oxygen-rich atmospheres. The researchers studied several metals. Nickel and cobalt alloys exhibit high burn resistances and are dense. The researchers next turned to ceramics, which they knew do not act as ignition sources. Unlike metals, ceramics are naturally burn-resistant. Unfortunately, they also exhibit low fracture toughnesses.

  4. Composite panels based on woven sandwich-fabric preforms

    NASA Astrophysics Data System (ADS)

    van Vuure, Aart Willem

    A new type of sandwich material was investigated, based on woven sandwich-fabric preforms. Because of the integrally woven nature of the sandwich-fabric the skin-core debonding resistance of panels and structures based on the preform is very high. As the sandwich-fabrics are produced by a large scale textile weaving process (velvet weaving or distance weaving) and already a preform of a sandwich is available, the cost of the final panel or structure can potentially stay limited. Most attention in this work is focussed on the mechanical performance of sandwich-fabric panels. The high skin-core debonding resistance was verified and also indications were found of a good damage tolerance. Both unfoamed and foamed panels were evaluated and compared with existing sandwich panels. Microstructural parameters investigated for unfoamed cores are pile length, pile density, woven pile angles, degree of pile stretching, tilt angles of the piles induced during panel production and resin content and distribution. For foamed panels it is especially the foam density which has an important influence. There appears to be a synergistic effect between piles and foam in the sandwich core, leading to very acceptable mechanical properties. For panels for (semi) structural applications, foaming is almost indispensable once the panel thickness is higher than about 15 mm. To understand the behaviour of foamed panels, attention was paid to the modelling of the mechanics of pure foam. The foam microstructure was modelled with the model of an anisotropic tetrakaidecahedron. The mechanical properties of unfoamed panels were modelled with the help of finite elements. A detailed geometrical description of the core layout was made which was incorporated into a preprocessing program for a finite element code. Attention is paid to the production of panels based on the woven preforms. A newly developed Adhesive Foil Stretching process was investigated. Also the foaming of panels was studied. A lot of attention was paid to a special application in the field of structural damping, where sandwich-fabric panels could be used as spacer in a constrained layer application. The vibrations and damping were modelled with the help of finite elements.

  5. Development of the First Cisgenic Apple with Increased Resistance to Fire Blight

    PubMed Central

    Kost, Thomas D.; Gessler, Cesare; Jänsch, Melanie; Flachowsky, Henryk; Patocchi, Andrea; Broggini, Giovanni A. L.

    2015-01-01

    The generation and selection of novel fire blight resistant apple genotypes would greatly improve the management of this devastating disease, caused by Erwinia amylovora. Such resistant genotypes are currently developed by conventional breeding, but novel breeding technologies including cisgenesis could be an alternative approach. A cisgenic apple line C44.4.146 was regenerated using the cisgene FB_MR5 from wild apple Malus ×robusta 5 (Mr5), and the previously established method involving A. tumefaciens-mediated transformation of the fire blight susceptible cultivar ‘Gala Galaxy’ using the binary vector p9-Dao-FLPi. The line C44.4.146 was shown to carry only the cisgene FB_MR5, controlled by its native regulatory sequences and no transgenes were detected by PCR or Southern blot following heat induced recombinase-mediated elimination of the selectable markers. Although this line contains up to 452 bp of vector sequences, it still matches the original definition of cisgenesis. A single insertion of T-DNA into the genome of 'Gala Galaxy' in chromosome 16 was identified. Transcription of FB_MR5 in line C44.4.146 was similar to the transcription in classically bred descendants of Mr5. Three independent shoot inoculation experiments with a Mr5 avirulent strain of Erwinia amylovora were performed using scissors or syringe. Significantly lower disease symptoms were detected on shoots of the cisgenic line compared to those of untransformed 'Gala Galaxy'. Despite the fact that the pathogen can overcome this resistance by a single nucleotide mutation, this is, to our knowledge, the first prototype of a cisgenic apple with increased resistance to fire blight. PMID:26624292

  6. Resistance and cross-resistance profile of the diaryltriazine NNRTI and candidate microbicide UAMC01398.

    PubMed

    Ariën, Kevin K; Venkatraj, Muthusamy; Michiels, Johan; Joossens, Jurgen; Vereecken, Katleen; Van der Veken, Pieter; Heeres, Jan; De Winter, Hans; Heyndrickx, Leo; Augustyns, Koen; Vanham, Guido

    2016-05-01

    The resistance development, cross-resistance to other NNRTIs and the impact of resistance on viral replicative fitness were studied for the new and potent NNRTI UAMC01398. Resistance was selected by dose escalation and by single high-dose selection against a comprehensive panel of NNRTIs used as therapeutics and NNRTIs under investigation for pre-exposure prophylaxis of sexual HIV transmission. A panel of 27 site-directed mutants with single mutations or combinations of mutations involved in reverse transcriptase (RT) inhibitor-mediated resistance was developed and used to confirm resistance to UAMC01398. Cross-resistance to other NNRTIs was assessed, as well as susceptibility of UAMC01398-resistant HIV to diarylpyrimidine-resistant viruses. Finally, the impact of UAMC01398 resistance on HIV replicative fitness was studied. We showed that UAMC01398 has potent activity against dapivirine-resistant HIV, that at least four mutations in the RT are required in concert for resistance and that the resistance profile is similar to rilpivirine, both genotypically and phenotypically. Resistance development to UAMC01398 is associated with a severe fitness cost. These data, together with the enhanced safety profile and good solubility in aqueous gels, make UAMC01398 an excellent candidate for HIV topical prevention. © The Author 2016. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  7. Impact damage resistance of composite fuselage structure, part 1

    NASA Technical Reports Server (NTRS)

    Dost, E. F.; Avery, W. B.; Ilcewicz, L. B.; Grande, D. H.; Coxon, B. R.

    1992-01-01

    The impact damage resistance of laminated composite transport aircraft fuselage structures was studied experimentally. A statistically based designed experiment was used to examine numerous material, laminate, structural, and extrinsic (e.g., impactor type) variables. The relative importance and quantitative measure of the effect of each variable and variable interactions on responses including impactor dynamic response, visibility, and internal damage state were determined. The study utilized 32 three-stiffener panels, each with a unique combination of material type, material forms, and structural geometry. Two manufacturing techniques, tow placement and tape lamination, were used to build panels representative of potential fuselage crown, keel, and lower side-panel designs. Various combinations of impactor variables representing various foreign-object-impact threats to the aircraft were examined. Impacts performed at different structural locations within each panel (e.g., skin midbay, stiffener attaching flange, etc.) were considered separate parallel experiments. The relationship between input variables, measured damage states, and structural response to this damage are presented including recommendations for materials and impact test methods for fuselage structure.

  8. Accurate genomic predictions for BCWD resistance in rainbow trout are achieved using low-density SNP panels: Evidence that long-range LD is a major contributing factor.

    PubMed

    Vallejo, Roger L; Silva, Rafael M O; Evenhuis, Jason P; Gao, Guangtu; Liu, Sixin; Parsons, James E; Martin, Kyle E; Wiens, Gregory D; Lourenco, Daniela A L; Leeds, Timothy D; Palti, Yniv

    2018-06-05

    Previously accurate genomic predictions for Bacterial cold water disease (BCWD) resistance in rainbow trout were obtained using a medium-density single nucleotide polymorphism (SNP) array. Here, the impact of lower-density SNP panels on the accuracy of genomic predictions was investigated in a commercial rainbow trout breeding population. Using progeny performance data, the accuracy of genomic breeding values (GEBV) using 35K, 10K, 3K, 1K, 500, 300 and 200 SNP panels as well as a panel with 70 quantitative trait loci (QTL)-flanking SNP was compared. The GEBVs were estimated using the Bayesian method BayesB, single-step GBLUP (ssGBLUP) and weighted ssGBLUP (wssGBLUP). The accuracy of GEBVs remained high despite the sharp reductions in SNP density, and even with 500 SNP accuracy was higher than the pedigree-based prediction (0.50-0.56 versus 0.36). Furthermore, the prediction accuracy with the 70 QTL-flanking SNP (0.65-0.72) was similar to the panel with 35K SNP (0.65-0.71). Genomewide linkage disequilibrium (LD) analysis revealed strong LD (r 2  ≥ 0.25) spanning on average over 1 Mb across the rainbow trout genome. This long-range LD likely contributed to the accurate genomic predictions with the low-density SNP panels. Population structure analysis supported the hypothesis that long-range LD in this population may be caused by admixture. Results suggest that lower-cost, low-density SNP panels can be used for implementing genomic selection for BCWD resistance in rainbow trout breeding programs. © 2018 The Authors. This article is a U.S. Government work and is in the public domain in the USA. Journal of Animal Breeding and Genetics published by Blackwell Verlag GmbH.

  9. Defense Standardization Program Journal. April/September 2012

    DTIC Science & Technology

    2012-01-01

    were magnified. In 1905, a committee of the National Fire Protection Association established a national standard for the diameter and threads per inch...for fire hydrants and hose couplings. The standard specifies that fire hydrants have 2.5-inch hose connections with 7.5 threads per inch and that...dsp.dla.mil I Field of view, lens material haze, luminous transmittance, and lens abrasion resistance (APR) I Communications (APR) I Fogging (APR

  10. Fire Safety Aspects of Polymeric Materials. Volume 6. Aircraft. Civil and Military

    DTIC Science & Technology

    1977-01-01

    resistance of the existing Polyurethane foam- based seating sys- tems be improved through design, construction, and selection of covering materials. 12. A...aircraft interiors under real fire conditions. To provide the data base for developing improved fire safety standards for aircraft, four types of...the determination of immobilizing effect was based on performance in the swimming test, a simple exercise method also favored by Kimmerle to provide

  11. Fire resistance properties of ceramic wool fiber reinforced intumescent coatings

    NASA Astrophysics Data System (ADS)

    Amir, N.; Othman, W. M. S. W.; Ahmad, F.

    2015-07-01

    This research studied the effects of varied weight percentage and length of ceramic wool fiber (CWF) reinforcement to fire retardant performance of epoxy-based intumescent coating. Ten formulations were developed using ammonium polyphosphate (APP), expandable graphite (EG), melamine (MEL) and boric acid (BA). The mixing was conducted in two stages; powdered materials were grinded in Rocklabs mortar grinder and epoxy-mixed using Caframo mixer at low speed mixing. The samples were applied on mild steel substrate and exposed to 500°C heat inside Carbolite electric furnace. The char expansion and its physical properties were observed. Scanning electron microscopy (SEM) analyses were conducted to inspect the fiber dispersion, fiber condition and the cell structure of both coatings and chars produced. Thermogravimetric analyses (TGA) were conducted to study the thermal properties of the coating such as degradation temperature and residual weight. Fire retardant performance was determined by measuring backside temperature of substrate in 1-hour, 1000°C Bunsen burner test according to UL 1709 fire regime. The results showed that intumescent coating reinforced with CWF produced better fire resistance performance. When compared to unreinforced coating, formulation S6-15 significantly reduced steel temperature at approximately 34.7% to around 175°C. However, higher fiber weight percentage had slightly decreased fire retardant performance of the coating.

  12. Studies of emotional instability in smoke from fires: Decrease of thinking powers and of memory in fire smoke

    NASA Astrophysics Data System (ADS)

    Jin, T.

    The effect and degree of smoke concentration on the reduction in thinking and memory was studied. The change in memory and thinking power was estimated by the change in correction ratio for mental calculation in various smoke concentrations. The reduction of memory in a smokey environment estimated by the correction ratio for remembering the order of four color panels which were shown before smoke exposure. It is found that it is difficult to evaluate the relationship between the reduction in thinking power against smoke concentration, and relationship between the reductions of memory against smoke concentration.

  13. Fighting fire with fire: physicians blazing new paths to autonomy.

    PubMed

    Vavala, D

    1995-04-01

    Thousands of physicians around the country have stopped complaining about being burned by the system and have started reengineering their destinies. They're building super IPAs, forming and operating HMOs, and joining unions to represent their rights in a growing grassroots physician effort to regain control. These physicians have thumbed their noses at managed care companies they say have drastically cut reimbursements, arbitrarily dropped them from panels, dictated utilization, and cost them patients. They're tired of working harder and earning less and frustrated by sacrificing quality in the name of cost reduction. And they have learned that there are ways to prevail.

  14. A Full-Scale Fire Program to Evaluate New Furnishings and Textile Materials Developed by the National Aeronautics and Space Administration

    NASA Technical Reports Server (NTRS)

    Hillenbrand, L. J.; Wray, J. A.

    1973-01-01

    The plans for the present series of full-scale experimental fires were initiated at the suggestion of NASA following the presentation of a film and discussion illustrating Battelle-Columbus' recent work in fire research. That film showed bedroom-type fires carried out as a part of a program to determine the influence of the cyclic characteristics of real fires under limited ventilation on the burning and pyrolysis properties of the room furnishings. A new series of fires was suggested by NASA designed to show the performance of new fire resistant and fire retardant materials by providing comparative fire and smoldering environmental conditions. More recently, the goal for the new series of fires was written in a meeting with NASA personnel and others at Battelle on May 3 and 4, 1972. The goal was as follows: To establish the need for special materials of improved fire safety in domiciliary settings of public concern, and to assess, in a professionally acceptable manner, the potential of materials arising from the new space-age technology for this purpose. It was anticipated that some new materials arising from the space-age technology and not yet available through conventional commercial channels might provide significant improvements in fire safety if the best of the commercially available materials showed important shortcomings in this area. It was the intent of this program to assess the benefits that could accrue from the use of these new materials. Fire safety is a matter requiring the evaluation of a number of factors. For example, fire resistance and fire spread, visibility during the fire, toxicity of evolved gases, and the fire-fighting problem that is created must be evaluated before the relative hazard can be assessed. The plan of the program provided for sampling and instrumentation to evaluate these factors, consistent with the goal of technological utilization that has been specified. Arrangements were made with the Columbus Fire Department to use an existing six-story concrete building', designed and used as a fire training tower, as the site for the experimental fires. The visual evidence provided by TV and photographic coverage of the four experimental room fires showed clearly that the rooms responded very differently to a common ignition condition. In particular: (1) The Typical room, furnished from conventional retail sources, ignited easily and burned rapidly so that after 8 minutes the contents of the room were nearly destroyed. (2) The Improved room, furnished with materials selected as being among the best commercially available, showed substantial improvement over the Typical room in that there was slower fire spread. However, the relatively complete destruction of the room contents that resulted, and the large amounts of smoke, made it clear that substantial further improvements were needed. This fire was stopped after 29 minutes. (3) The Space-age room, furnished completely with new materials that were not yet commercially available, did not ignite under the common ignition condition and soon demonstrated the substantial improvement in fire resistance available for those components close to the ignition source. A second and larger ignition arrangement showed that this room can burn, but the difficulty with which this was brought about confirmed the improved fire resistance available with use of these materials. (4) The Mixed room ensemble, furnished with 'materials identical to the Typical room except for the substitution of the bed from the Space-age room, illustrated the improvement in control of fire spread available by careful placement of fire materials in the important paths of fire development of an otherwise ordinary room. The most significant hazards at early times in each fire were due to the rapid rise in heat flux and the abrupt obscuration of vision by smoke. The most consistent toxicity hazard was due to CO and its importance would depend on the ability of the occupant to survive the initial heat and smoke menace which characterized each fire room. Other gases and vapors were shown to reach hazardous levels in certain fire rooms and, again, their significance to an occupant, would relate to the times in which such hazards occurred, and probably to the synergistic nature of the hazard arising from mixtures of such gases. Fire retardant items in the room are caused to pyrolyze by the heat of burning from other items in the room and so contribute to combustible and toxic vapor accumulations, even though they may not have entered into the burning process. This effect of a mixture of combustible materials to produce burning and pyrolysis not characteristic of any one item individually we have chosen to call the "ensemble effect". Further full-scale fire trials may be expected to show the significant changes that control the burning and pyrolytic processes and in that event a programmed fire chamber should be developed to yield realistic laboratory results.

  15. Integrated Control of Fire Blight with Bacterial Antagonists and Oxytetracycline

    USDA-ARS?s Scientific Manuscript database

    In the Pacific Northwest of the United States, the antibiotic streptomycin provided excellent control of fire blight until resistant isolates of Erwinia amylovora were prevalent. Oxytetracycline (Mycoshield) is now sprayed as an alternative antibiotic. We found that the duration of inhibitory acti...

  16. Integrated Control of Fire Blight with Antagonists and Oxytetracycline

    USDA-ARS?s Scientific Manuscript database

    In the Pacific Northwest of the United States, the antibiotic streptomycin provided excellent control of fire blight until resistant isolates of Erwinia amylovora arose. Oxytetracycline (Mycoshield) is now sprayed as an alternative antibiotic. We found that the duration of inhibitory activity of o...

  17. Fire extinguishing tests -80 with methyl alcohol gasoline (in MIXED)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holmstedt, G.; Ryderman, A.; Carlsson, B.

    1980-01-01

    Large scale tests and laboratory experiments were carried out for estimating the extinguishing effectiveness of three alcohol resistant aqueous film forming foams (AFFF), two alcohol resistant fluoroprotein foams and two detergent foams in various poolfires: gasoline, isopropyl alcohol, acetone, methyl-ethyl ketone, methyl alcohol and M15 (a gasoline, methyl alcohol, isobutene mixture). The scaling down of large scale tests for developing a reliable laboratory method was especially examined. The tests were performed with semidirect foam application, in pools of 50, 11, 4, 0.6, and 0.25 sq m. Burning time, temperature distribution in the liquid, and thermal radiation were determined. An M15more » fire can be extinguished with a detergent foam, but it is impossible to extinguish fires in polar solvents, such as methyl alcohol, acetone, and isopropyl alcohol with detergent foams, AFFF give the best results, and performances with small pools can hardly be correlated with results from large scale fires.« less

  18. Taxonomically-linked growth phenotypes during arsenic stress among arsenic resistant bacteria isolated from soils overlying the Centralia coal seam fire.

    PubMed

    Dunivin, Taylor K; Miller, Justine; Shade, Ashley

    2018-01-01

    Arsenic (As), a toxic element, has impacted life since early Earth. Thus, microorganisms have evolved many As resistance and tolerance mechanisms to improve their survival outcomes given As exposure. We isolated As resistant bacteria from Centralia, PA, the site of an underground coal seam fire that has been burning since 1962. From a 57.4°C soil collected from a vent above the fire, we isolated 25 unique aerobic As resistant bacterial strains spanning seven genera. We examined their diversity, resistance gene content, transformation abilities, inhibitory concentrations, and growth phenotypes. Although As concentrations were low at the time of soil collection (2.58 ppm), isolates had high minimum inhibitory concentrations (MICs) of arsenate and arsenite (>300 mM and 20 mM respectively), and most isolates were capable of arsenate reduction. We screened isolates (PCR and sequencing) using 12 published primer sets for six As resistance genes (AsRGs). Genes encoding arsenate reductase (arsC) and arsenite efflux pumps (arsB, ACR3(2)) were present, and phylogenetic incongruence between 16S rRNA genes and AsRGs provided evidence for horizontal gene transfer. A detailed investigation of differences in isolate growth phenotypes across As concentrations (lag time to exponential growth, maximum growth rate, and maximum OD590) showed a relationship with taxonomy, providing information that could help to predict an isolate's performance given As exposure in situ. Our results suggest that microbiological management and remediation of environmental As could be informed by taxonomically-linked As tolerance, potential for resistance gene transferability, and the rare biosphere.

  19. Public acceptance of wildland fire and fuel management: panel responses in seven locations.

    PubMed

    Toman, Eric; Shindler, Bruce; McCaffrey, Sarah; Bennett, James

    2014-09-01

    Wildland fire affects both public and private resources throughout the United States. A century of fire suppression has contributed to changing ecological conditions and accumulated fuel loads. Managers have used a variety of approaches to address these conditions and reduce the likelihood of wildland fires that may result in adverse ecological impacts and threaten communities. Public acceptance is a critical component of developing and implementing successful management programs. This study examines the factors that influence citizen support for agency fuel reduction treatments over time-particularly prescribed fire and mechanical vegetation removal. This paper presents findings from a longitudinal study examining resident beliefs and attitudes regarding fire management and fuels treatments in seven states: Arizona, Colorado, Oregon, Utah, Michigan, Minnesota, and Wisconsin. The study was implemented in two phases over a 6-year period using mail surveys to residents of communities adjacent to federal lands in each location. Questions replicated measures from the original project as well as some new items to allow a more in-depth analysis of key concepts. The study design enables comparisons over time as well as between locations. We also assess the factors that influence acceptance of both prescribed fire and mechanical vegetation removal. Findings demonstrate a relative stability of attitudes toward fuels management approaches over time and suggest that this acceptance is strongly influenced by confidence in resource managers and beliefs that the treatments would result in positive outcomes.

  20. Fire and heat resistant laminating resins based on maleimido substituted aromatic cyclotriphosphazene polymer

    NASA Technical Reports Server (NTRS)

    Kumar, Devendra (Inventor); Fohlen, George M. (Inventor); Parker, John A. (Inventor)

    1987-01-01

    4-Aminophenoxy cyclotriphosphazenes are reacted with maleic anhydride to produce maleamic acids which are converted to the maleimides. The maleimides are polymerized. By selection of starting materials (e.g., hexakis amino or trisaminophenoxy trisphenoxy cyclotriphosphazenes), selection of molar proportions of reactants, use of mixtures of anhydrides and use of dianhydrides as bridging groups a variety of maleimides and polymers are produced. The polymers have high limiting oxygen indices, high char yields and other useful heat and fire resistant properties making them useful as, for example, impregnants of fabrics.

  1. Water Resistant Container Technical Basis Document for the TA-55 Criticality Safety Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Paul Herrick; Teague, Jonathan Gayle

    Criticality safety at TA-55 relies on nuclear material containers that are water resistant to prevent significant amounts of water from coming into contact with fissile material in the event of a fire that causes a breach of glovevbox confinement and subsequent fire water ingress. A “water tight container” is a container that will not allow more than 50ml of water ingress when fully submerged, except when under sufficient pressure to produce structural discontinuity. There are many types of containers, welded containers, hermetically sealed containers, filtered containers, etc.

  2. Aerospace materials for nonaerospace applications

    NASA Technical Reports Server (NTRS)

    Johnston, R. L.; Dawn, F. S.

    1974-01-01

    Many of the flame-resistant nonmetallic materials that were developed for the Apollo and Skylab programs are discussed for commercial and military applications. Interchanges of information are taking place with the government agencies, industries, and educational institutions, which are interested in applications of fire-safe nonmetallic materials. These materials are particularly applicable to the design of aircraft, mass transit interiors, residential and public building constructions, nursing homes and hospitals, and to other fields of fire safety applications. Figures 22, 23 and 24 show the potential nonaerospace applications of flame-resistant aerospace materials are shown.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anggoro, Didi Dwi, E-mail: anggorophd@gmail.com; Kristiana, Nunung, E-mail: nuna.c631@gmail.com

    Ballistic protection equipment, such as a bulletproof vest, is a soldier’s most important means of preserving life and survivability in extreme combat conditions. The bulletproof vests are designed to protect the user’s chest from injury without disturbing the ability to perform his duties. Aromatic polyamide or aramid fibers known under the trade name Kevlar, Trawon and so is synthetic fiber materials commonly used in the manufacture of bulletproof vests. This synthetic fibers have high tensile strength and ductility. Kevlar is expensive and imported material. In this study, will introduce local natural raw materials, ramie fiber (Boehmeria nivea) which is cheapermore » and environmentally friendly. It has enough tenacity and tensile strength as a bulletproof vest. This experiment uses two panels, there are Panel A as front surface of Panel B. Panel A is a combination of ramie and epoxide matrix, while panel B is only ramie. From several variations of experimental combinations between Panel A and Panel B, optimal combination obtained with 16 layers of panel A and 31-34 layers of panel B which is able to protect againts cal. 7.65 mm × 17 mm (.32 ACP) bullet fired through pistol .32 Pindad from a distance of 20 meters. Panel with a size of 20 cm × 20 cm has a total thickness between 12,922 to13,745 mm and a total weight between 506,26 to 520,926gram. Scanning electron microscopy (SEM) observations indicated that the porosity and surface area of the ramie fiber is smooth, fiber surfaces showed topography with micropores. SEM also showed well-arranged structure of fibers bonding. Energy Dispersive X-ray (EDX) analysis indicated 100 % carbon contents in ramie fiber. Test result indicates that panel from composite ramie-epoxide can reach the level 1of International Standard of NIJ - 010104. Compared to panel from polyester fiber, the panel from composite ramie-epoxide (0,50-0,52 kg) is lighter weight than panel polyester fiber (1,642 kg)« less

  4. Combination of natural fiber Boehmeria nivea (ramie) with matrix epoxide for bullet proof vest body armor

    NASA Astrophysics Data System (ADS)

    Anggoro, Didi Dwi; Kristiana, Nunung

    2015-12-01

    Ballistic protection equipment, such as a bulletproof vest, is a soldier's most important means of preserving life and survivability in extreme combat conditions. The bulletproof vests are designed to protect the user's chest from injury without disturbing the ability to perform his duties. Aromatic polyamide or aramid fibers known under the trade name Kevlar, Trawon and so is synthetic fiber materials commonly used in the manufacture of bulletproof vests. This synthetic fibers have high tensile strength and ductility. Kevlar is expensive and imported material. In this study, will introduce local natural raw materials, ramie fiber (Boehmeria nivea) which is cheaper and environmentally friendly. It has enough tenacity and tensile strength as a bulletproof vest. This experiment uses two panels, there are Panel A as front surface of Panel B. Panel A is a combination of ramie and epoxide matrix, while panel B is only ramie. From several variations of experimental combinations between Panel A and Panel B, optimal combination obtained with 16 layers of panel A and 31-34 layers of panel B which is able to protect againts cal. 7.65 mm × 17 mm (.32 ACP) bullet fired through pistol .32 Pindad from a distance of 20 meters. Panel with a size of 20 cm × 20 cm has a total thickness between 12,922 to13,745 mm and a total weight between 506,26 to 520,926gram. Scanning electron microscopy (SEM) observations indicated that the porosity and surface area of the ramie fiber is smooth, fiber surfaces showed topography with micropores. SEM also showed well-arranged structure of fibers bonding. Energy Dispersive X-ray (EDX) analysis indicated 100 % carbon contents in ramie fiber. Test result indicates that panel from composite ramie-epoxide can reach the level 1of International Standard of NIJ - 010104. Compared to panel from polyester fiber, the panel from composite ramie-epoxide (0,50-0,52 kg) is lighter weight than panel polyester fiber (1,642 kg).

  5. 78 FR 62640 - National Institute of Allergy and Infectious Diseases; Notice of Closed Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-22

    ... confidential trade secrets or commercial property such as patentable material, and personal information... Infectious Diseases Special Emphasis Panel; Drug Target Development and Validation for Antimicrobial... Emphasis Panel; Drug Target Development and Validation for Antimicrobial Resistant Pathogens (R21/R33...

  6. Anthropogenic fire drives the evolution of seed traits

    PubMed Central

    Gómez-González, Susana; Torres-Díaz, Cristian; Bustos-Schindler, Carlos; Gianoli, Ernesto

    2011-01-01

    Fire is a major disturbance affecting ecosystems worldwide. Phylogenetic studies have shown that the evolution of seed persistence (fire resistance) is associated with fire frequency or severity. However, the existence of specific seed traits resulting from natural selection mediated by fire remains a key question in plant evolution. We evaluated the role of fire in the evolution of seed traits from a microevolutionary perspective, using as a study system a native forb from the Chilean matorral, where fire is a novel, anthropogenic disturbance. We show that anthropogenic fires are shaping the evolution of seed traits such as pubescence and shape. Among-population variation in seed pubescence, shape, and pericarp thickness was strongly associated with fire frequency, and within a population, fire selected those plants with more pubescent seeds, thicker pericarps, and less rounded seeds. Seed pubescence and shape were shown to be heritable traits. Our findings provide insights into the understanding of the evolution of seed traits in fire-prone environments and demonstrate that human-made fires can be driving evolutionary changes in plant species from ecosystems where fires do not occur naturally. PMID:22065739

  7. Anthropogenic fire drives the evolution of seed traits.

    PubMed

    Gómez-González, Susana; Torres-Díaz, Cristian; Bustos-Schindler, Carlos; Gianoli, Ernesto

    2011-11-15

    Fire is a major disturbance affecting ecosystems worldwide. Phylogenetic studies have shown that the evolution of seed persistence (fire resistance) is associated with fire frequency or severity. However, the existence of specific seed traits resulting from natural selection mediated by fire remains a key question in plant evolution. We evaluated the role of fire in the evolution of seed traits from a microevolutionary perspective, using as a study system a native forb from the Chilean matorral, where fire is a novel, anthropogenic disturbance. We show that anthropogenic fires are shaping the evolution of seed traits such as pubescence and shape. Among-population variation in seed pubescence, shape, and pericarp thickness was strongly associated with fire frequency, and within a population, fire selected those plants with more pubescent seeds, thicker pericarps, and less rounded seeds. Seed pubescence and shape were shown to be heritable traits. Our findings provide insights into the understanding of the evolution of seed traits in fire-prone environments and demonstrate that human-made fires can be driving evolutionary changes in plant species from ecosystems where fires do not occur naturally.

  8. Genome-wide association mapping of anthracnose (Collectotrichum sublineolun) resistance in U.S. sorghum association panel

    USDA-ARS?s Scientific Manuscript database

    The productivity and profitability of sorghum [Sorghum bicolor (L.) Moench] is reduced by susceptibility to fungal diseases such as anthracnose, which causes yield loss of both grain and biomass. A limited number of resistant accessions are present in temperate adapted germplasm, while resistant sou...

  9. Composite Sandwich Structures for Shock Mitigation and Energy Absorption

    DTIC Science & Technology

    2016-06-28

    analysis of the blast performance of foam -core, composite sandwich panels was that on a per unit areal weight density basis, lighter and more crushable... foam cores offered greater blast resistance and energy absorption than the heavier and stronger foam cores. This was found to be the case even on an...absolute weight basis for cuNed sandwich panels and panels subjected to underwater blast. 15. SUBJECT TERMS composite; foam -core sandwich; blast

  10. Panel discussion: prescribed burning in the 21st century

    Treesearch

    Jerry Hurley; Ishmael Messer; Stephen J. Botti; Jay Perkins; L. Dean Clark

    1995-01-01

    Even though many legal, social, and organizational constraints affect prescribed fire programs, the ecological and social benefits of such programs encourage their continued existence (with or without modification). The form of these programs in the next 10 to 50 years is pure speculation; but we must speculate and project the programs, as well as associated benefits...

  11. 75 FR 61521 - NUREG/CR-7010, Cable Heat Release, Ignition, and Spread in Tray Installations During Fire...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-05

    ... tray configurations. The experiments conducted range from micro-scale, in which very small (5 mg... burned under a large oxygen- depletion calorimeter. Other experiments include cone calorimetry, smoke and... tray of cables underneath a bank of radiant panels. The results of the small-scale experiments are to...

  12. A/E/C CAD Standard, Release 5.0

    DTIC Science & Technology

    2012-12-01

    System Control Panels Halon System Inert Gas Smoke/Pressurization Control Egress Requirements Fire Protection System Appendix A ... System Natural Gas System Miter Gates Makeup Air System Appendix A Model File Level/Layer Assignment Tables A54 Discipline: Mechanical Model...SWITCHES Element type: Symbol Electrical: STP14B SURFACE 1X4 STRIP BATTERY Element type: Symbol Electrical: SUBST A

  13. 77 FR 38468 - Airworthiness Directives; Bombardier, Inc. Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-28

    ... was prompted by a report of a ground fire which was fed by oxygen escaping from a damaged third crew person oxygen line and had started in the vicinity of an electrical panel. This AD requires replacing and changing the routing of the flexible oxygen hose of the third crew person oxygen line and modifying the...

  14. The case of the high-risk safety product.

    PubMed

    Chew, W B; Blodgett, T B; Wallin, W R; Meyers, G C; Holden, B; Johnson, E W; Smith, N C; Ducker, W

    1992-01-01

    After several days of meetings, J.F. Winchester, president of MDC Industries, felt no closer to a decision. MDC, a manufacturer of wall and ceiling panels, was considering whether to exercise an option to buy a new and safer wallboard technology. The product was being touted as revolutionary, but, Winchester wondered, could MDC afford to carry the flag? According to its inventor, Robert Goerner, Smoke-Safe would be a vast improvement over standard safety-rated wallboard. With almost the same flame-retardant properties, Smoke-Safe had the advantage of giving off almost no fumes or smoke in fire tests. And, Winchester knew, most fire-related deaths are from smoke, not flames. Indeed, the numbers were grimly persuasive: 82% of fire-related injuries involving standard panels were caused by smoke inhalation. What's more, Smoke-Safe would cost about the same to manufacture as MDC's current wallboard. But MDC had several other good options for spending the $5 million Goerner was asking; building plastics was only one of its profit centers. And the prospect of launching a campaign to change building codes in order to market Smoke-Safe, which could spark a fight with competitors, was daunting. Since its current wallboard gave MDC only 18% of the wallboard market, many industry insiders speculated whether MDC had the market clout to influence major cities to revise their codes. Six experts in marketing, law, and ethics advise MDC Industries on how it can balance ethical and business imperatives in making its decision.

  15. Identification of New Resistance Loci to African Stem Rust Race TTKSK in Tetraploid Wheats Based on Linkage and Genome-Wide Association Mapping.

    PubMed

    Laidò, Giovanni; Panio, Giosuè; Marone, Daniela; Russo, Maria A; Ficco, Donatella B M; Giovanniello, Valentina; Cattivelli, Luigi; Steffenson, Brian; de Vita, Pasquale; Mastrangelo, Anna M

    2015-01-01

    Stem rust, caused by Puccinia graminis Pers. f. sp. tritici Eriks. and E. Henn. (Pgt), is one of the most destructive diseases of wheat. Races of the pathogen in the "Ug99 lineage" are of international concern due to their virulence for widely used stem rust resistance genes and their spread throughout Africa. Disease resistant cultivars provide one of the best means for controlling stem rust. To identify quantitative trait loci (QTL) conferring resistance to African stem rust race TTKSK at the seedling stage, we evaluated an association mapping (AM) panel consisting of 230 tetraploid wheat accessions under greenhouse conditions. A high level of phenotypic variation was observed in response to race TTKSK in the AM panel, allowing for genome-wide association mapping of resistance QTL in wild, landrace, and cultivated tetraploid wheats. Thirty-five resistance QTL were identified on all chromosomes, and seventeen are of particular interest as identified by multiple associations. Many of the identified resistance loci were coincident with previously identified rust resistance genes; however, nine on chromosomes 1AL, 2AL, 4AL, 5BL, and 7BS may be novel. To validate AM results, a biparental population of 146 recombinant inbred lines was also considered, which derived from a cross between the resistant cultivar "Cirillo" and susceptible "Neodur." The stem rust resistance of Cirillo was conferred by a single gene on the distal region of chromosome arm 6AL in an interval map coincident with the resistance gene Sr13, and confirmed one of the resistance loci identified by AM. A search for candidate resistance genes was carried out in the regions where QTL were identified, and many of them corresponded to NBS-LRR genes and protein kinases with LRR domains. The results obtained in the present study are of great interest as a high level of genetic variability for resistance to race TTKSK was described in a germplasm panel comprising most of the tetraploid wheat sub-species.

  16. U.S. Air Force Aircrew Flight Protective Eyewear Program

    DTIC Science & Technology

    2013-02-01

    MIL-DTL-32000), fire - resistant hydraulic fluid (MIL-PRF-46170), petroleum-based hydraulic fluid (MIL-PRF-6083), gasoline (87% octane), motor oil...UPLC installed. ABRASION FPE spectacles and goggles shall maximize resistance to scratching/ abrasion to minimize interference with vision...Visual Area ................................................................................. 2 3.0 BALLISTIC AND IMPACT RESISTANCE : BALLISTIC

  17. 30 CFR 57.4533 - Mine opening vicinity.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and... materials; or (b) Constructed to meet a fire resistance rating of no less than one hour; or (c) Provided...

  18. Plant community diversity and composition provide little resistance to Juniperus encroachment

    Treesearch

    Amy C. Ganguli; David M. Engle; Paul M. Mayer; Eric C. Heligren

    2008-01-01

    Widespread encroachment of the fire-intolerant species Juniperus virginiana L. into North American grasslands and savannahs where fire has largely been removed has prompted the need to identify mechanisms driving J. virginiana encroachment. We tested whether encroachment success of J. virginiana is related to...

  19. Wildfires and Schools

    ERIC Educational Resources Information Center

    National Clearinghouse for Educational Facilities, 2009

    2009-01-01

    This publication discusses conditions that feed wildfires, how a building catches fire, determining the school's risk, creating a survivable space for the school, the importance of maintenance, the fire-resistant school, meeting code requirements, and related flood and mudslide risks. Much of this publication has been adapted for schools from the…

  20. Post-processing flame-retardant for polyurethane

    NASA Technical Reports Server (NTRS)

    Monaghan, P.; Sidman, K. R.

    1980-01-01

    Treatment of polyurethane form with elastomer formulation after processing makes foam fire resistant without compromising physical properties. In testing, once ignition source is removed, combustion stops. Treatment also prevents molten particle formation, generates no smoke or toxic gases in fire, and does not deteriorate under prolonged exposure to Sun.

Top